Powered by Deep Web Technologies
Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Zhengzhi Wang  

Science Conference Proceedings (OSTI)

... ZZ Wang, P. Gu, Z. Zhang, L. Gu and YZ Xu, "Mechanical and tribological behavior of epoxy/Silica nanocomposites at the micro/nano scale", Tribol. ...

2012-11-14T23:59:59.000Z

2

Liping Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

Liping Wang Liping Wang Liping Wang Simulation Research Group Lawrence Berkeley National Laboratory 1 Cyclotron Road MS 90R3147 Berkeley CA 94720 (510) 486-4000 LWang@lbl.gov Liping Wang is a Mechanical Engineering Postdoc in the Simulation Research Group. Her current research interests include energy efficient building systems, building energy simulation, fault detection and diagnostics. Prior to joining LBNL, she was a research engineer in Energy System Lab at Texas A&M University. She also has postdoctoral research experience on zero energy building projects from Wales School of Architecture at Cardiff University, United Kingdom. Liping received her Ph.D. degree in Building Technology from National University of Singapore. Her dissertation focused on coupling building simulation and CFD for the prediction of thermal

3

Lan Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

Lan Wang Professor China Building Materials Academy (Beijing) This speaker was a visiting speaker who delivered a talk or talks on the date(s) shown at the links below. This...

4

Zhihui Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

Portrait of Zhihui Wang Portrait of Zhihui Wang Zhihui Wang Electrochemical Technologies Group Lawrence Berkeley National Laboratory 1 Cyclotron Road MS 70R0108B Berkeley CA 94720 Office Location: 70-0286 (510) 486-6586 ZHWang@lbl.gov I am a chemist and my research is focused on both environmental science and energy storage technology. I got my B.S. and M.S. degrees in Peking University. Then I earned my Ph.D. at State University of New York at Stony Brook. My dissertation work was focused on atmospheric carbon monoxide source strengths from preindustrial times to present day. Then I changed the direction of my study to energy storage technology. I am currently working on the anode and cathode materials in lithium ion batteries. Below is my professional experience: Chemist Postdoctoral Fellow, Lawrence Berkeley National Laboratory,

5

Jia Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

Jia Wang Jia Wang Chemist Chemistry Department Building 555 Brookhaven National Laboratory P.O. Box 5000 Upton, NY 11973-5000 Phone: (631) 344-2515 FAX: (631) 344-5815 e-mail Surface Electrochemistry and Electrocatalysis Research Interests Surface electrochemistry, electrocatalysis, nanomaterials synthesis, fuel cells, water electrolysis, and surface X-ray scattering study of single crystal electrodes. Education Ph.D Chemistry 1987, City University of New York. B.S. Chemistry 1982, Beijing Normal University. Professional Employment Brookhaven National Laboratory 1996, Chemist 1993, Associate Chemist 1991, Assistant scientist 1989, Research Associate Princeton University 1987-1989: Research Associate Awards R&D 100 Award from R&D Magazine, 2012 Representative Publications

6

Dr. Lili Wang  

Science Conference Proceedings (OSTI)

... L. Wang, J. Blasic, MJ Holden, and R. Pires. Sensitivity Comparison of Various Real-Time PCR Probe Designs on a Model DNA Plasmid. Anal. ...

2012-10-01T23:59:59.000Z

7

Abstract for Qinghai Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

Qinghai Wang Washington University in St. Louis PT-Symmetric Quantum Field Theory and a New interpretation of the Lee Model In this talk I will review non-Hermitian PT-symmetric...

8

NREL: Energy Sciences - Wei Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

Wei Wang Wei Wang Research Scientist Photo of Wei Wang Phone: (303) 384-7945 Email: wei.wang@nrel.gov At NREL Since: 2009 Dr. Wei Wang joined NREL in 2009 as a Research Scientist. Her main research interests are conversion of biomass to value-added products. Dr. Wang is also interested in fundamental studies of biomass degradation including biochemical mechanisms of key enzyme systems for biomass conversion. Her current work at NREL focuses on understanding the chemical and physical factors governing biomass recalcitrance to enzymatic hydrolysis. Dr. Wang received a Ph.D. in Microbiology from Shandong University in China in 2002. During her Ph.D. studies, she worked on the metabolism of degradation of lignocellulose by brown-rot fungi and proposed that a hydroxyl radical-mediated, oxidative mechanism is involved in the

9

Michael Q. Wang resume  

NLE Websites -- All DOE Office Websites (Extended Search)

Q. Wang Q. Wang Argonne National Laboratory Center for Transportation Research 9700 South Cass Avenue, Building 362 Argonne, IL 60439-4837 phone: 630/252-2819, fax: 630/252-3443 e-mail: mqwang@anl.gov Professional Experience  1993-Present. Section manager as well as vehicle and fuel systems analyst at the Center for Transportation Research in the Energy Systems Division at Argonne National Laboratory  1992-1993. Assistant research engineer, Institute of Transportation Studies, University of California at Davis  1991-1993. Special-term scientist appointee, Center for Transportation Research, Energy Systems Division, Argonne National Laboratory  1991-1992. Postdoctoral researcher, Center for Transportation Analysis, Oak Ridge National Laboratory

10

Global Monsoon across timescales Pinxian Wang Bin Wang Thorsten Kiefer  

E-Print Network (OSTI)

EDITORIAL Global Monsoon across timescales Pinxian Wang · Bin Wang · Thorsten Kiefer Published online: 28 July 2012 ? Springer-Verlag 2012 Scientific focus on monsoons can be traced back nearly 350 years. However, only recently have monsoons been analyzed as a global system. Traditionally

Wang, Bin

11

Wen-Bohr (Dennis) Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

Dennis Wang Dennis Wang Director Energy Conservation Center Taiwan Green Productivity Foundation This speaker was a visiting speaker who delivered a talk or talks on the date(s) shown at the links below. This speaker is not otherwise associated with Lawrence Berkeley National Laboratory, unless specifically identified as a Berkeley Lab staff member. (Dr. Wang is also Vice-Chairman of the Taiwan Association of Energy Services Company.)Wen-Bohr Wang earned his Ph.D. in Chemical Engineering at the University of Tulsa in 1985, (USA). He established the Energy Technical Service Center of CTCI Foundation in May of 1991. He reorganized it to become the Energy Conservation Center of the Taiwan Green Productivity Foundation in January of 2005.Dr. Wang has been responsible for energy

12

wang-98.pdf  

NLE Websites -- All DOE Office Websites (Extended Search)

7 7 Relative Humidity Variations in the Tropical Western Pacific and Relations with Deep Convective Clouds J. Wang and J. A. Curry Program in Atmospheric and Oceanic Sciences University of Colorado Boulder, Colorado Introduction Most general circulation models (GCMs) agree that water vapor feedback due to warming caused by increasing greenhouse gases is positive (Cess et al. 1990). However, Lindzen (1990) argued that GCMs might overestimate the water vapor feedback because increased convection in a warmer climate would actually dry the upper troposphere. A number of studies have been conducted 1) to test whether the atmosphere is observed to be more humid in a warmer climate (e.g., Rind et al. 1991), and 2) to study the direct relationship between deep convections and humidity (e.g.,

13

Chao Wang Publications - Argonne National Laboratories, Materials...  

NLE Websites -- All DOE Office Websites (Extended Search)

of Homogeneous Pt-Bimetallic Nanoparticles as Highly Efficient Electrocatalysts", ACS Catalysis 2011, accepted. 31. Dennis van der Vliet, Chao Wang, Mark Debe, Radoslav...

14

Publications  

NLE Websites -- All DOE Office Websites (Extended Search)

XML Sort by: Author Title Type Year (Desc) Filters: Keyword is LBNL Stove Testing Facility Clear All Filters Submitted Wang, Yungang, Michael D. Sohn, Yilun Wang, Kathleen M....

15

Submitting Jobs  

NLE Websites -- All DOE Office Websites (Extended Search)

Submitting Jobs Submitting Jobs Submitting Jobs Submitting your job If you are submitting your job on Genepool or Phoebe you do NOT need to source any batch settings. The batch environment has been loaded into your path by default. If qsub is not working properly, check to make sure that the uge module is loaded: module load uge If you are submitting a job from an external submit host you need to source the appropriate settings.sh file for Genepool or Phoebe. source /opt/uge/genepool/uge/genepool/common/settings.sh qsub commands and options UGE (Univa Grid Engine) is the batch system used for Genepool/Phoebe. Action How to do it Comment Submit a job qsub script In UGE you need to submit a script, not an executable. Specify number of processors for a threaded job qsub -pe pe_slots 8 ... Request 8 cores on a single node for your job. Please specify as many processors as will be needed during your job.

16

Chao Wang - Argonne National Laboratories, Materials Sicence...  

NLE Websites -- All DOE Office Websites (Extended Search)

enabled to view it. Quick Links Chao Wang Publications Complete CV Education 2008 Ph.D. Electrical and Materials Science Engineering, Brown University 2005 M.S. Electrical and...

17

Dr. Xiaoping Wang | ORNL Neutron Sciences  

NLE Websites -- All DOE Office Websites (Extended Search)

Home › Contact Us › CV Home › Contact Us › CV Dr. Xiaoping Wang Instrument Scientist TOPAZ BL-12 Dr. Xiaoping Wang received his Ph.D. degree in inorganic chemistry from Texas A&M University in 1998, where he did his graduate work with Professor F. Albert Cotton. He then undertook postdoctoral research in neutron crystallography at Argonne National Laboratory. He was the director for crystallographic computing in the Laboratory for Molecular Structure and Bonding at Texas A&M University from December 2001 to May 2006; the director of X-Ray Diffraction Laboratory at University of North Texas from June 2006 to July 2008, and has been appointed as adjunct professor in the chemistry department. Dr. Wang is currently an instrument scientist co-responsible for the TOPAZ single crystal diffractometer (SNS

18

Respectfully Submitted  

E-Print Network (OSTI)

Pt. 590 (2003), please find enclosed the application of BG LNG Services, LLC ("BGLS") for long-term authorization to import liquefied natural gas pursuant to Section 3 of the Natural Gas Act, as amended. Also please find enclosed a check for $50 made payable to the Treasury of the United States as required by 10 C.F.R. 590.207. Pursuant to 10 C.F.R. 590.202(e) and 1004.11, BGLS hereby notifies DOE that the Master LNG Sale and Purchase Agreement between BGLS and Mitsubishi International Corporation ("Sales Agreement"), which is the subject of this application, contains highly sensitive commercial information that is exempt from public disclosure. The Sales Agreement, which is attached to the application as Exhibit B, contains certain commercially sensitive terms the disclosure of which would place BGLS at a commercial disadvantage. Accordingly, BGLS is providing one original copy of the application clearly marked "Contains Confidential Information-Do Not Release " and 15 copies with the confidential information redacted from the Sales Agreement. Those copies are clearly marked "Privileged Information Removed For Confidential Treatment. " Notwithstanding the filing of a redacted copy of the application, BGLS reserves its right, pursuant to 10 C.F.R. 1004.11(c), to be notified prior to any disclosure of the confidential information and to be allowed an opportunity to submit its views with respect to such disclosure.

The Willard; Office Building; John S. Decker; Sally Kornfeld; Cm- A; Forrestal Building; Jol S. Decker

2004-01-01T23:59:59.000Z

19

The role of ammonia on mercury leaching from coal fly ash Jianmin Wang a,*, Tian Wang a  

E-Print Network (OSTI)

analysis of fly ash disposal in mined areas. In: Proceedings of the 12th International Symposium on CoalThe role of ammonia on mercury leaching from coal fly ash Jianmin Wang a,*, Tian Wang a , Harmanjit, 2005). CAIR permanently caps emissions of NOx and SOx from large stationary sources including coal

Ragsdell, Kenneth M.

20

Massively parallel Wang Landau sampling on multiple GPUs  

Science Conference Proceedings (OSTI)

Wang Landau sampling is implemented on the Graphics Processing Unit (GPU) with the Compute Unified Device Architecture (CUDA). Performances on three different GPU cards, including the new generation Fermi architecture card, are compared with that on a Central Processing Unit (CPU). The parameters for massively parallel Wang Landau sampling are tuned in order to achieve fast convergence. For simulations of the water cluster systems, we obtain an average of over 50 times speedup for a given workload.

Yin, Junqi [ORNL; Landau, D. P. [UGA

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Z.L. Wang's biosketch Dr. Zhong Lin (ZL) Wang is the Hightower Chair in Materials Science and Engineering, Regents'  

E-Print Network (OSTI)

of America, and the 2009 Purdy award from American ceramic society. Dr. Wang has made original and innovative the worldwide effort in academia and industry for studying energy for micro-nano-systems, which is now

Wang, Zhong L.

22

Letter to Science from Michael Wang, Center for Transportation Research, Argonne National Laboratory  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Letter to Science (Original version submitted to Science on Feb. 14 th , 2008; revised on March 14 th , 2008) Michael Wang Center for Transportation Research Argonne National Laboratory Zia Haq Office of Biomass Program Office of Energy Efficiency and Renewable Energy U.S. Department of Energy The article by Searchinger et al. in Sciencexpress ("Use of U.S. Croplands for Biofuels Increases Greenhouse Gases through Emissions from Land Use Change," February 7, 2008) provides a timely discussion of fuel ethanol's effects on greenhouse gas (GHG) emissions when taking into account GHG emissions from potential land use changes induced by ethanol production. Land use change issues associated with biofuels were explored in life-cycle analyses beginning

23

DOE submits Yucca Mtn  

NLE Websites -- All DOE Office Websites (Extended Search)

submits Yucca Mountain license application; Argonne contributes science, engineering support The U.S. Department of Energy reached a milestone in its efforts to help enable the...

24

Xiaoyu (Shawn) Wang | Renewable Energy Group | Sustainable Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Xiaoyu (Shawn) Wang Xiaoyu (Shawn) Wang Education Nanyang Technological University, Ph. D in Power Engr. North China Electric Power University, MSc in Power Engr. North China Electric Power University, BSc in Power Engr. Expertise Power systems modeling Controller design for power electronic devices especially for renewable energy integration incorporated with energy storage systems (ESS) Dynamic modeling of wind and solar energy resources Membership IEEE Reviewer for: IEEE Transactions on Smart Grid IEEE Transactions on Sustainable Energy IEEE Transactions on Power Delivery IEEE Transactions on Energy Conversion IEEE Transactions on Industrial Electronics Electric Power System Research European Transactions on Electrical Power Experience Brookhaven National Laboratory, 2010 - present

25

Pseudospin Ferromagnetism in Double-Quantum-Wire Systems D.-W. Wang,1  

E-Print Network (OSTI)

Pseudospin Ferromagnetism in Double-Quantum-Wire Systems D.-W. Wang,1 E. G. Mishchenko,2 and E (Wiley, New York, 1997), p. 161; J. P. Eisenstein, ibid., p. 37, and references therein. [8] D.-W. Wang); R. Klesse and A. Stern, Phys. Rev. B 62, 16912 (2000). [15] E. Mishchenko, D.-W. Wang, and E. Demler

Demler, Eugene

26

Recursive Wang tiles for real-time blue noise  

Science Conference Proceedings (OSTI)

Well distributed point sets play an important role in a variety of computer graphics contexts, such as anti-aliasing, global illumination, halftoning, non-photorealistic rendering, point-based modeling and rendering, and geometry processing. In this ... Keywords: Poisson disk distribution, Wang tiles, anti-aliasing, blue noise, non-periodic tiling, object positioning, sampling, stippling, texture synthesis

Johannes Kopf; Daniel Cohen-Or; Oliver Deussen; Dani Lischinski

2006-07-01T23:59:59.000Z

27

Bayesian Variable Selection and the Swendsen-Wang Algorithm  

E-Print Network (OSTI)

Bayesian Variable Selection and the Swendsen-Wang Algorithm David J. NOTT and Peter J. GREEN improvements in Markov chain Monte Carlo sampling algorithms for Bayesian variable selection. Currently used, this excludes the ith predictor from the model. The problem of variable selection is to decide which predictors

Green, Peter

28

Bayesian variable selection and the Swendsen-Wang algorithm  

E-Print Network (OSTI)

Bayesian variable selection and the Swendsen-Wang algorithm David J. Nott1 and Peter J. Green2 1 motivated improvements in Markov chain Monte Carlo sampling algorithms for Bayesian variable selection. Traditional sampling al- gorithms for Bayesian variable selection may perform poorly when there are severe

Barber, Stuart

29

Energy Harvesting for Self-Powered Nanosystems Zhong Lin Wang  

E-Print Network (OSTI)

Energy Harvesting for Self-Powered Nanosystems Zhong Lin Wang School of Materials Science In this article, an introduction is presented about the energy harvesting technologies that have potential. This is a potential technology for converting mechanical movement energy (such as body movement, muscle stretching

Wang, Zhong L.

30

Submitting PDSF Jobs  

NLE Websites -- All DOE Office Websites (Extended Search)

Submitting PDSF Jobs Submitting PDSF Jobs Submitting PDSF Jobs Univa Grid Engine (UGE) is the batch system used at PDSF. This is a fork of the Sun Grid Engine (SGE). PDSF batch jobs have a 1 day wallclock limit. If your job attempts to run beyond the wallclock limit UGE will kill it. The total number of jobs (running, pending or otherwise) for all users is limited to 30,000 and the number of jobs a single user can have at any one time is limited to 5000. Since PDSF is a shared facility any jobs that are detrimental to the overall performance of the batch system are subject to being deleted at the discretion of the PDSF staff. If this happens, you will be notified and asked to adjust your workflow as necessary. If you are planning to submit thousands of short jobs concurrently consider

31

10 Questions for a Senior Scientist: Michael Wang | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Senior Scientist: Michael Wang Senior Scientist: Michael Wang 10 Questions for a Senior Scientist: Michael Wang July 21, 2011 - 4:33pm Addthis Senior Scientist Michael Wang uses his favorite tool at Argonne -- the GREET tool he helped develop. | Courtesy of Argonne Senior Scientist Michael Wang uses his favorite tool at Argonne -- the GREET tool he helped develop. | Courtesy of Argonne Niketa Kumar Niketa Kumar Public Affairs Specialist, Office of Public Affairs Our research efforts help us understand the technology trends, their potential and the hurdles for some technologies to get into the marketplace. Michael Wang, Senior Scientist At Argonne National Laboratory's Center for Transportation Research (CTR), Dr. Wang's work spans a wide range -- from transportation fuels to advanced vehicles technologies. His team also developed GREET (Greenhouse gases,

32

Cermet Filters  

INLs cermet filter is self-cleaning and reduces pollutant emissions, e.g. NOx in vehicles, which can be harmful in heavier duty diesel trucks. This filter lasts far longer compared to other filters because it is self-cleaning, which avoids plugging.

33

Fermilab | Tune IT Up | Submit a Question  

NLE Websites -- All DOE Office Websites (Extended Search)

Submit a Question To submit questions about cyber security at Fermilab, please complete the form below. Name: Email: Question: submit...

34

Granular filter  

SciTech Connect

The invention described and claimed in this application relates to granular filters and, more particularly, to continuously regenerate granular filters operatable at high temperature and pressure which are particularly suited for cleaning gas used to operate a gas turbine. The filter is of relatively small size and by nature of its operation couples high filtering efficiency with maximum practicable protection to downstream equipment from ash from combustion of the solid fuel and from small particle of the filtering medium entrained in the flowing gas, which would case deposit buildup and erosion to the turbine blades.

Lear, D.E. Jr; Schmid, A.H.; Wigton, H.F.H.

1977-07-12T23:59:59.000Z

35

ARM - Submitting Proposals : Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

govField CampaignsSubmitting Proposals : Guidelines govField CampaignsSubmitting Proposals : Guidelines Schedule and Availability Preproposals now open for AMF and AAF Preproposals due 1 Feb Invited full proposals due 1 May AAF available Dec 2015 AMF1 available Apr 2016 AMF2 available early 2017 AMF3 available for guest instrumentation or intensive operational periods Forms Propose a Campaign Form Instrument Support Request (ISR) Form (Word, 89KB) Documentation Steps to Send Campaign Data to ARM Data Archive Field Campaign Guidelines (PDF, 1.1MB) Submitting Proposals : Guidelines Proposals are welcome from all members of the scientific community for conducting field campaigns and scientific research using the ARM Climate Research Facility sites at the Southern Great Plains (SGP), North Slope of Alaska (NSA), Tropical Western Pacific (TWP), one of the ARM Mobile

36

Filtering apparatus  

DOE Patents (OSTI)

A vertical vessel having a lower inlet and an upper outlet enclosure separated by a main horizontal tube sheet. The inlet enclosure receives the flue gas from a boiler of a power system and the outlet enclosure supplies cleaned gas to the turbines. The inlet enclosure contains a plurality of particulate-removing clusters, each having a plurality of filter units. Each filter unit includes a filter clean-gas chamber defined by a plate and a perforated auxiliary tube sheet with filter tubes suspended from each tube sheet and a tube connected to each chamber for passing cleaned gas to the outlet enclosure. The clusters are suspended from the main tube sheet with their filter units extending vertically and the filter tubes passing through the tube sheet and opening in the outlet enclosure. The flue gas is circulated about the outside surfaces of the filter tubes and the particulate is absorbed in the pores of the filter tubes. Pulses to clean the filter tubes are passed through their inner holes through tubes free of bends which are aligned with the tubes that pass the clean gas.

Haldipur, Gaurang B. (Monroeville, PA); Dilmore, William J. (Murrysville, PA)

1992-01-01T23:59:59.000Z

37

Filtering apparatus  

DOE Patents (OSTI)

A vertical vessel is described having a lower inlet and an upper outlet enclosure separated by a main horizontal tube sheet. The inlet enclosure receives the flue gas from a boiler of a power system and the outlet enclosure supplies cleaned gas to the turbines. The inlet enclosure contains a plurality of particulate-removing clusters, each having a plurality of filter units. Each filter unit includes a filter clean-gas chamber defined by a plate and a perforated auxiliary tube sheet with filter tubes suspended from each tube sheet and a tube connected to each chamber for passing cleaned gas to the outlet enclosure. The clusters are suspended from the main tube sheet with their filter units extending vertically and the filter tubes passing through the tube sheet and opening in the outlet enclosure. The flue gas is circulated about the outside surfaces of the filter tubes and the particulate is absorbed in the pores of the filter tubes. Pulses to clean the filter tubes are passed through their inner holes through tubes free of bends which are aligned with the tubes that pass the clean gas. 18 figs.

Haldipur, G.B.; Dilmore, W.J.

1992-09-01T23:59:59.000Z

38

FINAL Submitted to NREL  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Submitted to NREL Submitted to NREL 10-21-11 City of Naperville Case Study 1 An example of an automated switch used in Naperville's distribution automation systems. At the Forefront of the Smart Grid: Empowering Consumers in Naperville, Illinois Naperville, Illinois, is a suburban community located outside of Chicago. Typical in many ways, Naperville is the fifth largest city in Illnois and an active, engaged citizenry that is environmentally conscious and technically savvy. In fact, the National Renewable Energy Laboratory's recent assessment of leading utility green power programs ranks Naperville as No. 5 in the nation in percentage of customer participation. 1 Additionally, about one-quarter of Naperville's electricity customers pay their

39

Submitting Batch Jobs on Franklin  

NLE Websites -- All DOE Office Websites (Extended Search)

Submitting Batch Jobs Submitting Batch Jobs Debug Jobs Short jobs requesting less than 30 minutes and requiring 512 nodes (2,048 cores) or fewer can run in the debug queue. From...

40

Ethernet filter  

DOE Patents (OSTI)

This invention is comprised of an apparatus and method that prevents access to unauthorized data in a local area network, such as Ethernet, in which information is transmitted from a transceiver to at least one workstation. Encoded data packets transmitted from the transceiver are filtered by splitting the packet into two signals. One signal contains the data that was transmitted, while the other signal contains tainted data. The filter determines whether a workstation is authorized to access the data, and then delivers either the tainted data to unauthorized workstations, or the data that was transmitted to authorized workstations.

Charney, E.J.; Tanzella, A.J.; Wujcik, J.G.

1990-11-09T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

George Srajer and Jin Wang Elected Fellows of the American Physical...  

NLE Websites -- All DOE Office Websites (Extended Search)

in 1984 and a Ph. D. from Ohio State University in 1994. After postdoctoral studies at Exxon, he started at Argonne as an Assistant Physicist in 1997. Wang's development of...

42

Submitting Batch Jobs on Carver  

NLE Websites -- All DOE Office Websites (Extended Search)

Submitting Batch Jobs Submitting Batch Jobs Submitting Batch Jobs Overview A batch job is the most common way users run production applications on NERSC machines. Carver's batch system is based on the PBS model, implemented with the Moab scheduler and Torque resource manager. Typically, the user submits a batch script to the batch system. This script specifies, at the very least, how many nodes and cores the job will use, how long the job will run, and the name of the application to run. The job will advance in the queue until it has reached the top. At this point, Torque will allocate the requested number of nodes to the batch job. The batch script itself will execute on the "head node" (sometimes known as the "MOM" node). See Queues and Policies for details of batch queues, limits,

43

Submitted Work & Work in Preparation - CECM  

E-Print Network (OSTI)

May 23, 2001 ... Submitted Work & Work in Preparation. I. G. Lisle and G. J. Reid, Symmetry Classification Using Invariant Moving Frames, to be submitted.

44

Submitting Batch Jobs on Franklin  

NLE Websites -- All DOE Office Websites (Extended Search)

Submitting Batch Jobs Submitting Batch Jobs Submitting Batch Jobs Debug Jobs Short jobs requesting less than 30 minutes and requiring 512 nodes (2,048 cores) or fewer can run in the debug queue. From 5am-6pm Pacific Time, 256 nodes are reserved for debugging and interactive use. See also, running Interactive Jobs. Sample Batch Scripts The following batch script requests 8 cores on 2 nodes with a 10 minute wall clock limit in the debug queue. Torque directive lines tell the batch system how to run a job and begin with #PBS. #PBS -q debug #PBS -l mppwidth=8 #PBS -l walltime=00:10:00 #PBS -j eo #PBS -V cd $PBS_O_WORKDIR aprun -n 8 ./a.out Here is another example requesting 8 processors using 4 nodes with only 2 cores per node: #PBS -q debug #PBS -l mppwidth=8 #PBS -l mppnppn=2 #PBS -l walltime=00:10:00

45

Hepa filter dissolution process  

DOE Patents (OSTI)

A process for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal.

Brewer, Ken N. (Arco, ID); Murphy, James A. (Idaho Falls, ID)

1994-01-01T23:59:59.000Z

46

HEPA filter dissolution process  

DOE Patents (OSTI)

A process is described for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal. 4 figures.

Brewer, K.N.; Murphy, J.A.

1994-02-22T23:59:59.000Z

47

Recirculating electric air filter  

DOE Patents (OSTI)

An electric air filter cartridge has a cylindrical inner high voltage eleode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

Bergman, Werner (Pleasanton, CA)

1986-01-01T23:59:59.000Z

48

HEPA filter dissolution process  

DOE Patents (OSTI)

This invention is comprised of a process for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal.

Brewer, K.N.; Murphy, J.A.

1992-12-31T23:59:59.000Z

49

Security Analysis of Lightweight Authentication Protocol from WISTP 2013 Wang Shao-HuiP  

E-Print Network (OSTI)

Security Analysis of Lightweight Authentication Protocol from WISTP 2013 Wang Shao-HuiP 1,2,3) P Key Laboratory for Wireless Sensor Networks, Nanjing 210003, China) P 3) P( Network and Data Security Frequency Identification (RFID) is security and privacy. Many RFID authentication protocols have been

International Association for Cryptologic Research (IACR)

50

Wind climatology of Schiphol Andrew Stepek, Xueli Wang and Dirk Wolters  

E-Print Network (OSTI)

Wind climatology of Schiphol Andrew Stepek, Xueli Wang and Dirk Wolters De Bilt, May 2012 #12;2 Contents Summary 2 Introduction 3 Data 3 Hourly wind measurements 3 Yearly averages of wind speed measurements 4 Quality and sources of error 6 Method 7 Trends in wind speed 7 Definition of cross and tail wind

Haak, Hein

51

Combustion stabilization using serpentine plasma actuators Chin-Cheng Wang and Subrata Roya)  

E-Print Network (OSTI)

Combustion stabilization using serpentine plasma actuators Chin-Cheng Wang and Subrata Roya 2011) This letter presents a numerical model for combustion stabilization with plasma actuators of Physics. [doi:10.1063/1.3615292] The topic of plasma assisted combustion (PAC) has been investigated

Roy, Subrata

52

Dr. Yeqiao (Y.Q.) Wang Professor in Terrestrial Remote Sensing  

E-Print Network (OSTI)

1 Dr. Yeqiao (Y.Q.) Wang Professor in Terrestrial Remote Sensing Department of Natural Resources://www.ltrs.uri.edu ________________________________________________________________________ Research Interests My research interests and teaching responsibilities are in terrestrial remote sensing. M.Sc., Natural Resources Management & Engineering: Univ. of Connecticut, 1992. M.Sc., Remote Sensing

Wang, Y.Q. "Yeqiao"

53

The Solar Wind in the Outer Heliosphere at Solar John D. Richardson and Chi Wang  

E-Print Network (OSTI)

The Solar Wind in the Outer Heliosphere at Solar Maximum John D. Richardson and Chi Wang Center solar wind observations in the outer heliosphere, concentrating on the recent data near solar maximum. The speed and temperature tend to be lower at solar maximum, due to the lack of coronal holes. The near

Richardson, John

54

Thin-film Lithium Niobate Contour-mode Resonators Renyuan Wang and Sunil A. Bhave  

E-Print Network (OSTI)

Thin-film Lithium Niobate Contour-mode Resonators Renyuan Wang and Sunil A. Bhave School Micro Devices, Inc. Greensboro, North Carolina, USA Abstract--This paper presents Lithium Niobate (LN this platform, we demonstrate, on a black Y136 cut Lithium Niobate thin-film, one-port high-order width

Afshari, Ehsan

55

MLWFA: A Multilingual Weather Forecast Text Generation Tianfang YAO Dongmo ZHANG Qian WANG  

E-Print Network (OSTI)

MLWFA: A Multilingual Weather Forecast Text Generation System1 Tianfang YAO Dongmo ZHANG Qian WANG generation; Weather forecast generation system Abstract In this demonstration, we present a system for multilingual text generation in the weather forecast domain. Multilingual Weather Forecast Assistant (MLWFA

Wu, Dekai

56

Quantum Teleportation in Quantum Dots System Hefeng Wang and Sabre Kais  

E-Print Network (OSTI)

Quantum Teleportation in Quantum Dots System Hefeng Wang and Sabre Kais Department of Chemistry of quantum teleportation protocol based on one-dimensional quantum dots system. Three quantum dots with three electrons are used to perform teleportation, the unknown qubit is encoded using one electron spin on quantum

Kais, Sabre

57

Quantum teleportation in one-dimensional quantum dots system Hefeng Wang, Sabre Kais *  

E-Print Network (OSTI)

Quantum teleportation in one-dimensional quantum dots system Hefeng Wang, Sabre Kais * Department of quantum teleportation protocol based on one-dimensional quantum dots system. Three quantum dots with three electrons are used to perform teleportation, the unknown qubit is encoded using one electron spin on quantum

Kais, Sabre

58

Physical Aging of Arsenic Trisulfide Thick Films and Bulk Materials Rong-Ping Wang,w  

E-Print Network (OSTI)

Physical Aging of Arsenic Trisulfide Thick Films and Bulk Materials Rong-Ping Wang,w Andrei Rode referred to as a physical aging phenomenon.7,8 To avoid the changes in physical properties caused by physical aging, a material with completely saturated aging should be used in chalcogenide-based devices

Chen, Ying

59

ARRANGEMENT FOR REPLACING FILTERS  

DOE Patents (OSTI)

An improved filtered air exhaust system which may be continually operated during the replacement of the filters without the escape of unfiltered air is described. This is accomplished by hermetically sealing the box like filter containers in a rectangular tunnel with neoprene covered sponge rubber sealing rings coated with a silicone impregnated pneumatic grease. The tunnel through which the filters are pushed is normal to the exhaust air duct. A number of unused filters are in line behind the filters in use, and are moved by a hydraulic ram so that a fresh filter is positioned in the air duct. The used filter is pushed into a waiting receptacle and is suitably disposed. This device permits a rapid and safe replacement of a radiation contaminated filter without interruption to the normal flow of exhaust air.

Blomgren, R.A.; Bohlin, N.J.C.

1957-08-27T23:59:59.000Z

60

Rigid porous filter  

DOE Patents (OSTI)

The present invention involves a porous rigid filter including a plurality of concentric filtration elements having internal flow passages and forming external flow passages there between. The present invention also involves a pressure vessel containing the filter for the removal of particulates from high pressure particulate containing gases, and further involves a method for using the filter to remove such particulates. The present filter has the advantage of requiring fewer filter elements due to the high surface area-to-volume ratio provided by the filter, requires a reduced pressure vessel size, and exhibits enhanced mechanical design properties, improved cleaning properties, configuration options, modularity and ease of fabrication.

Chiang, Ta-Kuan (Morgantown, WV); Straub, Douglas L. (Morgantown, WV); Dennis, Richard A. (Morgantown, WV)

2000-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Filter type gas sampler with filter consolidation  

DOE Patents (OSTI)

Disclosed is an apparatus for automatically consolidating a filter or, more specifically, an apparatus for drawing a volume of gas through a plurality of sections of a filter, whereafter the sections are subsequently combined for the purpose of simultaneously interrogating the sections to detect the presence of a contaminant.

Miley, Harry S. (219 Rockwood Dr., Richland, WA 99352); Thompson, Robert C. (5313 Phoebe La., West Richland, WA 99352); Hubbard, Charles W. (1900 Stevens, Apt. 526, Richland, WA 99352); Perkins, Richard W. (1413 Sunset, Richland, WA 99352)

1997-01-01T23:59:59.000Z

62

HEPA Filter Vulnerability Assessment  

SciTech Connect

This assessment of High Efficiency Particulate Air (HEPA) filter vulnerability was requested by the USDOE Office of River Protection (ORP) to satisfy a DOE-HQ directive to evaluate the effect of filter degradation on the facility authorization basis assumptions. Within the scope of this assessment are ventilation system HEPA filters that are classified as Safety-Class (SC) or Safety-Significant (SS) components that perform an accident mitigation function. The objective of the assessment is to verify whether HEPA filters that perform a safety function during an accident are likely to perform as intended to limit release of hazardous or radioactive materials, considering factors that could degrade the filters. Filter degradation factors considered include aging, wetting of filters, exposure to high temperature, exposure to corrosive or reactive chemicals, and exposure to radiation. Screening and evaluation criteria were developed by a site-wide group of HVAC engineers and HEPA filter experts from published empirical data. For River Protection Project (RPP) filters, the only degradation factor that exceeded the screening threshold was for filter aging. Subsequent evaluation of the effect of filter aging on the filter strength was conducted, and the results were compared with required performance to meet the conditions assumed in the RPP Authorization Basis (AB). It was found that the reduction in filter strength due to aging does not affect the filter performance requirements as specified in the AB. A portion of the HEPA filter vulnerability assessment is being conducted by the ORP and is not part of the scope of this study. The ORP is conducting an assessment of the existing policies and programs relating to maintenance, testing, and change-out of HEPA filters used for SC/SS service. This document presents the results of a HEPA filter vulnerability assessment conducted for the River protection project as requested by the DOE Office of River Protection.

GUSTAVSON, R.D.

2000-05-11T23:59:59.000Z

63

Cordierite silicon nitride filters  

SciTech Connect

The objective of this project was to develop a silicon nitride based crossflow filter. This report summarizes the findings and results of the project. The project was phased with Phase I consisting of filter material development and crossflow filter design. Phase II involved filter manufacturing, filter testing under simulated conditions and reporting the results. In Phase I, Cordierite Silicon Nitride (CSN) was developed and tested for permeability and strength. Target values for each of these parameters were established early in the program. The values were met by the material development effort in Phase I. The crossflow filter design effort proceeded by developing a macroscopic design based on required surface area and estimated stresses. Then the thermal and pressure stresses were estimated using finite element analysis. In Phase II of this program, the filter manufacturing technique was developed, and the manufactured filters were tested. The technique developed involved press-bonding extruded tiles to form a filter, producing a monolithic filter after sintering. Filters manufactured using this technique were tested at Acurex and at the Westinghouse Science and Technology Center. The filters did not delaminate during testing and operated and high collection efficiency and good cleanability. Further development in areas of sintering and filter design is recommended.

Sawyer, J.; Buchan, B. (Acurex Environmental Corp., Mountain View, CA (United States)); Duiven, R.; Berger, M. (Aerotherm Corp., Mountain View, CA (United States)); Cleveland, J.; Ferri, J. (GTE Products Corp., Towanda, PA (United States))

1992-02-01T23:59:59.000Z

64

Microsoft Word - AHEdoeprogressreportfinalreview093009submitted  

NLE Websites -- All DOE Office Websites (Extended Search)

Use Use of Air2Air TM Technology to Recover Fresh-Water from the Normal Evaporative Cooling Loss at Coal-Based Thermoelectric Power Plants Final Report Project Dates: 7/31/06 - 9/30/09 September 30, 2009 For DOE Funding Opportunity - Advanced Technologies and Concepts to Minimize Freshwater Use in Coal-Based Thermoelectric Power Plants Funding Opportunity Number: DE-PS26-05NT42411 Instrument Number: DEFC2605NT42725 CFDA Number: 81.089 Fossil Energy Research and Development Submitting Organiazation: SPX Cooling Technologies 7401 West 129 th Street Overland Park, KS 66213 Principal Author/Investigator: Ken Mortensen Phone: 913-664-7723 Fax: 913-664-7871 E-mail: ken.mortensen@spx.com II DISCLAIMER "This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof,

65

Attacking the Kad Network Peng Wang, James Tyra, Eric Chan-Tin, Tyson Malchow, Denis Foo Kune,  

E-Print Network (OSTI)

Attacking the Kad Network Peng Wang, James Tyra, Eric Chan-Tin, Tyson Malchow, Denis Foo Kune 55455 {pwang,tyra,dchantin,malchow,foo,hopper,kyd}@cs.umn.edu ABSTRACT The Kad network

Kim, Dae-Shik

66

Wang OIS glossary package for reformatting documents telecommunicated to the OIS system  

SciTech Connect

Documents that are composed on a computer and then transmitted by telecommunications into a Wang Office Information System (OIS) word processing system need to be reformatted and cleaned up before they can be used properly as word processing documents suitable for further revisions or additions. This report describes a group of glossary entries created for the Wang OIS which simplifies the job of cleaning up telecommunicated documents. This glossary is a semi-automated process designed to eliminate most of the tedious work needed to be performed in removing extra spaces and returns, adjusting formats, moving material, repagination, using tabs or indents, and similar problems. The report briefly discusses the problems, describes the glossary approach to solving them, and gives instructions for actually using the glossary entries.

Markow, S.R.

1983-12-09T23:59:59.000Z

67

Submitting Organization Hongyou Fan Sandia National Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

&24; 2007 R&D 100 Award Entry Form &24; Submitting Organization Hongyou Fan Sandia National Laboratories Advanced Materials Laboratory 1001 University Boulevard SE Albuquerque, NM...

68

Contactor/filter improvements  

DOE Patents (OSTI)

A contactor/filter arrangement for removing particulate contaminants from a gaseous stream is described. The filter includes a housing having a substantially vertically oriented granular material retention member with upstream and downstream faces, a substantially vertically oriented microporous gas filter element, wherein the retention member and the filter element are spaced apart to provide a zone for the passage of granular material therethrough. A gaseous stream containing particulate contaminants passes through the gas inlet means as well as through the upstream face of the granular material retention member, passing through the retention member, the body of granular material, the microporous gas filter element, exiting out of the gas outlet means. A cover screen isolates the filter element from contact with the moving granular bed. In one embodiment, the granular material is comprised of porous alumina impregnated with CuO, with the cover screen cleaned by the action of the moving granular material as well as by backflow pressure pulses. 6 figs.

Stelman, D.

1988-06-30T23:59:59.000Z

69

Linear phase compressive filter  

DOE Patents (OSTI)

A phase linear filter for soliton suppression is in the form of a laddered series of stages of non-commensurate low pass filters with each low pass filter having a series coupled inductance (L) and a reverse biased, voltage dependent varactor diode, to ground which acts as a variable capacitance (C). L and C values are set to levels which correspond to a linear or conventional phase linear filter. Inductance is mapped directly from that of an equivalent nonlinear transmission line and capacitance is mapped from the linear case using a large signal equivalent of a nonlinear transmission line.

McEwan, Thomas E. (Livermore, CA)

1995-01-01T23:59:59.000Z

70

Filter holder and gasket assembly for candle or tube filters  

DOE Patents (OSTI)

A filter holder and gasket assembly for holding a candle filter element within a hot gas cleanup system pressure vessel. The filter holder and gasket assembly includes a filter housing, an annular spacer ring securely attached within the filter housing, a gasket sock, a top gasket, a middle gasket and a cast nut.

Lippert, Thomas Edwin (Murrysville, PA); Alvin, Mary Anne (Pittsburgh, PA); Bruck, Gerald Joseph (Murrysville, PA); Smeltzer, Eugene E. (Export, PA)

1999-03-02T23:59:59.000Z

71

Sub-micron filter  

DOE Patents (OSTI)

Aluminum hydroxide fibers approximately 2 nanometers in diameter and with surface areas ranging from 200 to 650 m.sup.2/g have been found to be highly electropositive. When dispersed in water they are able to attach to and retain electronegative particles. When combined into a composite filter with other fibers or particles they can filter bacteria and nano size particulates such as viruses and colloidal particles at high flux through the filter. Such filters can be used for purification and sterilization of water, biological, medical and pharmaceutical fluids, and as a collector/concentrator for detection and assay of microbes and viruses. The alumina fibers are also capable of filtering sub-micron inorganic and metallic particles to produce ultra pure water. The fibers are suitable as a substrate for growth of cells. Macromolecules such as proteins may be separated from each other based on their electronegative charges.

Tepper, Frederick (Sanford, FL); Kaledin, Leonid (Port Orange, FL)

2009-10-13T23:59:59.000Z

72

Sintered composite filter  

DOE Patents (OSTI)

A particulate filter medium formed of a sintered composite of 0.5 micron diameter quartz fibers and 2 micron diameter stainless steel fibers is described. Preferred composition is about 40 vol.% quartz and about 60 vol.% stainless steel fibers. The media is sintered at about 1100/sup 0/C to bond the stainless steel fibers into a cage network which holds the quartz fibers. High filter efficiency and low flow resistance are provided by the smaller quartz fibers. High strength is provided by the stainless steel fibers. The resulting media has a high efficiency and low pressure drop similar to the standard HEPA media, with tensile strength at least four times greater, and a maximum operating temperature of about 550/sup 0/C. The invention also includes methods to form the composite media and a HEPA filter utilizing the composite media. The filter media can be used to filter particles in both liquids and gases.

Bergman, W.

1986-05-02T23:59:59.000Z

73

Property:Date Submitted | Open Energy Information  

Open Energy Info (EERE)

Date Submitted Date Submitted Jump to: navigation, search Property Name Date Submitted Property Type String Pages using the property "Date Submitted" Showing 25 pages using this property. (previous 25) (next 25) M MHK Technologies/14 MW OTECPOWER + 45:22.0 + MHK Technologies/Aegir Dynamo + 47:39.7 + MHK Technologies/AirWEC + 3/2/2013 + MHK Technologies/Anaconda bulge tube drives turbine + 35:14.3 + MHK Technologies/AquaBuoy + 9/2/2010 + MHK Technologies/Aquanator + 9/28/2010 + MHK Technologies/Aquantis + 47:31.6 + MHK Technologies/Archimedes Wave Swing + 9/28/2010 + MHK Technologies/Atlantis AN 150 + 6/18/2012 + MHK Technologies/Atlantis AR 1000 + 6/18/2012 + MHK Technologies/Atlantis AS 400 + 6/18/2012 + MHK Technologies/Atlantisstrom + 51:25.6 + MHK Technologies/BOLT Lifesaver + 04:16.3 +

74

FORMS AND INSTRUCTIONS FOR SUBMITTING ELECTRIC  

E-Print Network (OSTI)

CALIFORNIA ENERGY COMMISSION FORMS AND INSTRUCTIONS FOR SUBMITTING ELECTRIC TRANSMISSION Instructions for Electric Transmission Forms ............................................................. 6 Electric transmission, transmission corridor, data request. #12;1 Background The California Energy

75

Ceramic fiber reinforced filter  

DOE Patents (OSTI)

A filter for removing particulate matter from high temperature flowing fluids, and in particular gases, that is reinforced with ceramic fibers. The filter has a ceramic base fiber material in the form of a fabric, felt, paper of the like, with the refractory fibers thereof coated with a thin layer of a protective and bonding refractory applied by chemical vapor deposition techniques. This coating causes each fiber to be physically joined to adjoining fibers so as to prevent movement of the fibers during use and to increase the strength and toughness of the composite filter. Further, the coating can be selected to minimize any reactions between the constituents of the fluids and the fibers. A description is given of the formation of a composite filter using a felt preform of commercial silicon carbide fibers together with the coating of these fibers with pure silicon carbide. Filter efficiency approaching 100% has been demonstrated with these filters. The fiber base material is alternately made from aluminosilicate fibers, zirconia fibers and alumina fibers. Coating with Al.sub.2 O.sub.3 is also described. Advanced configurations for the composite filter are suggested.

Stinton, David P. (Knoxville, TN); McLaughlin, Jerry C. (Oak Ridge, TN); Lowden, Richard A. (Powell, TN)

1991-01-01T23:59:59.000Z

76

Zhihui Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

Laboratory, Berkeley, CA (2012-present) 1. Investigate thermal stability of silicon anode in Li-ion battery 2. Application of stabilized lithium metal powder (SLMP) in anode...

77

Shi Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

Division at Lawrence National Berkeley Laboratory. Her study focuses on distributed and renewable energy resources and software design. She works as part of the Distributed...

78

Yungang Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

the unknown distribution F, using repeated sampling of the obtained single set of data. Bootstrapping can be implemented by 10 constructing a number of resamples of the...

79

Duo Wang  

NLE Websites -- All DOE Office Websites (Extended Search)

"Duct systems in large commercial buildings: physical characterization, air leakage and heat conduction gains." Energy and Buildings 32, no. 1 (2000): 109-119. Download: PDF...

80

Wang Shi  

NLE Websites -- All DOE Office Websites (Extended Search)

developer in the world. China Vanke was founded in 1988 and listed on the Shenzhen Stock Exchange in 1991 as the second listed company in China. In 2012, Vanke developed...

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Improved methods for calculating thermodynamic properties of magnetic systems using Wang-Landau density of states  

SciTech Connect

The Wang-Landau method [F. Wang and D. P. Landau, Phys. Rev. E 64, 056101 (2001)] is an efficient way to calculate the density of states (DOS) for magnetic systems, and the DOS can then be used to rapidly calculate the thermodynamic properties of the system. A technique is presented that uses the DOS for a simple Hamiltonian to create a stratified sample of configurations which are then used calculate a warped DOS for more realistic Hamiltonians. This technique is validated for classical models of bcc Fe with exchange interactions of increasing range, but its real value is using the DOS for a model Hamiltonian calculated on a workstation to select the stratified set of configurations whose energies can then be calculated for a density-functional Hamiltonian. The result is an efficient first-principles calculation of thermodynamic properties such as the specific heat and magnetic susceptibility. Another technique uses the sample configurations to calculate the parameters of a model exchange interaction using a least-squares approach. The thermodynamic properties can be subsequently evaluated using traditional Monte Carlo techniques for the model exchange interaction. Finally, a technique that uses the configurations to train a neural network to estimate the configuration energy is also discussed. This technique could potentially be useful in identifying the configurations most important in calculating the warped DOS. VC2011 American Institute of Physics. [doi:10.1063/1.3565413

Brown, Greg [ORNL; Rusanu, Aurelian [ORNL; Daene, Markus W [ORNL; Nicholson, Don M [ORNL; Eisenbach, Markus [ORNL; Fidler, Jane L [ORNL

2011-01-01T23:59:59.000Z

82

Microhydropower Conveyance and Filters  

Energy.gov (U.S. Department of Energy (DOE))

Before water enters the turbine or waterwheel of a microhydropower system, it is funneled through a series of components that control its flow and filter out debris. These components include the...

83

PARS II Process Document- Submitting & Processing Email as Offical...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

PARS II Process Document- Submitting & Processing Email as Offical Project Action Approval Document PARS II Process Document- Submitting & Processing Email as Offical Project...

84

Video Tutorial for Submitting a 2014 ERCAP Request available  

NLE Websites -- All DOE Office Websites (Extended Search)

Video Tutorial for Submitting a 2014 ERCAP Request available Video Tutorial for Submitting a 2014 ERCAP Request available September 17, 2013 (0 Comments) Rushing to meet the...

85

Filters for cathodic arc plasmas  

DOE Patents (OSTI)

Cathodic arc plasmas are contaminated with macroparticles. A variety of magnetic plasma filters has been used with various success in removing the macroparticles from the plasma. An open-architecture, bent solenoid filter, with additional field coils at the filter entrance and exit, improves macroparticle filtering. In particular, a double-bent filter that is twisted out of plane forms a very compact and efficient filter. The coil turns further have a flat cross-section to promote macroparticle reflection out of the filter volume. An output conditioning system formed of an expander coil, a straightener coil, and a homogenizer, may be used with the magnetic filter for expanding the filtered plasma beam to cover a larger area of the target. A cathodic arc plasma deposition system using this filter can be used for the deposition of ultrathin amorphous hard carbon (a-C) films for the magnetic storage industry.

Anders, Andre (Albany, CA); MacGill, Robert A. (Richmond, CA); Bilek, Marcela M. M. (Engadine, AU); Brown, Ian G. (Berkeley, CA)

2002-01-01T23:59:59.000Z

86

Remotely serviced filter and housing  

DOE Patents (OSTI)

A filter system for a hot cell comprises a housing adapted for input of air or other gas to be filtered, flow of the air through a filter element, and exit of filtered air. The housing is tapered at the top to make it easy to insert a filter cartridge holds the filter element while the air or other gas is passed through the filter element. Captive bolts in trunnion nuts are readily operated by electromechanical manipulators operating power wrenches to secure and release the filter cartridge. The filter cartridge is adapted to make it easy to change a filter element by using a master-slave manipulator at a shielded window station. 6 figs.

Ross, M.J.; Zaladonis, L.A.

1987-07-22T23:59:59.000Z

87

Web-based Mathematics Education: MeML Design and Implementation Paul S. Wang Yi Zhou Xiao Zou  

E-Print Network (OSTI)

Web-based Mathematics Education: MeML Design and Implementation Paul S. Wang Yi Zhou Xiao Zou 44242, USA Kent, OH 44242, USA pwang@cs.kent.edu yizhou@cs.kent.edu xzou@cs.kent.edu Abstract The Web-based Mathematics Education framework (WME) aims to create a Web for mathematics education. WME empowers mathematics

Selinger, Robin L. Blumberg

88

Integral Input-to-State Stability of the Drive-Train of a Wind Turbine Chen Wang and George Weiss  

E-Print Network (OSTI)

generating units based on a doubly-fed induction generator (DFIG), as shown in Figure 1, have been widely of the equations of a DFIG in the stator- flux reference frame shows that the electrical torque is C. Wang; #12; # $ Fig. 1. Control of a grid-connected wind-driven DFIG with back-to-back converters

Sontag, Eduardo

89

Third-order gas-liquid phase transition and the nature of Andrews critical Tian Ma and Shouhong Wang  

E-Print Network (OSTI)

Third-order gas-liquid phase transition and the nature of Andrews critical point Tian Ma-order gas-liquid phase transition and the nature of Andrews critical point Tian Ma1 and Shouhong Wang2 1 is to study the nature of the Andrews critical point in the gas-liquid transition in a physical

Wang, Shouhong

90

Correlated solar wind speed, density, and magnetic field changes at J. D. Richardson and C. Wang1  

E-Print Network (OSTI)

., in press, 2003. Wang, C., and J. D. Richardson, Energy partition between solar wind protons and pickup ionsCorrelated solar wind speed, density, and magnetic field changes at Voyager 2 J. D. Richardson December 2003. [1] The character of the solar wind plasma data observed by Voyager 2 recently changed

Richardson, John

91

Versatile High-Fidelity Photovoltaic Module Emulation Woojoo Lee, Younghyun Kim, Yanzhi Wang, Naehyuck Chang, Massoud Pedram,  

E-Print Network (OSTI)

}@elpl.snu.ac.kr, shhan@konkuk.ac.kr ABSTRACT Photovoltaic (PV) cells are promising endurable renewable power sourcesVersatile High-Fidelity Photovoltaic Module Emulation System Woojoo Lee, Younghyun Kim, Yanzhi Wang. The proposed PV module emulation system includes a pilot PV cell, temperature sensors, an accelerometer

Pedram, Massoud

92

Ming Jiang and Ge Wang: Recent Advances in Iterative Algorithms Page 1 of 13 Development of Iterative Algorithms for Image  

E-Print Network (OSTI)

of Radiology University of Iowa Iowa City, IA 52242, USA ge-wang@ieee.org http on the initial guesses, and so on. In addition, heuristic arguments are given for the SART and EM algorithms of Radiology University of Iowa 200 Hawkins Drive Iowa City, Iowa 52242, USA (P) (319) 356-8376 (F) (319) 356

Jiang, Ming

93

Book Review published by Analysis, 1997: Reflection Electron Microscopy and Spectroscopy for Surface Analysis, By Zhong Lin Wang  

E-Print Network (OSTI)

Book Review published by Analysis, 1997: Reflection Electron Microscopy and Spectroscopy for Surface Analysis, By Zhong Lin Wang Professor John F. Watts University of Surrey The book describes, but the author is considerate enough to define them all in the early pages of his book. The dust-cover notes

Wang, Zhong L.

94

An Introduction to Fuel Cells and Related Transport Phenomena Matthew M. Mench, Chao-Yang Wang and Stefan T. Thynell  

E-Print Network (OSTI)

be dried by hot inlet flow, ideally saturated near the middle of the cell, and experiencing flooding near1 An Introduction to Fuel Cells and Related Transport Phenomena Matthew M. Mench, Chao-Yang Wang of fuel cell systems for primary or auxiliary power for stationary, portable, and automotive systems has

Wang, Chao-Yang

95

ESS 2012 Peer Review - New Generation Aqueous Base Redox Flow Battery Component Development - Wei Wang, PNNL  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Generation Aqueous Base Redox Flow Generation Aqueous Base Redox Flow Battery Component Development Wei Wang, Qingtao Luo, Xiaoliang Wei, Bin Li, Zimin Nie, Baowei Chen, Yuyan Shao, Vijayakumar Murugesan, Amy Chen, Gordon, Xia, Liyu Li, Gary Z. Yang, Vincent Sprenkle Pacific Northwest National Laboratory 902 Battelle Boulevard P. O. Box 999 Richland, WA 99352, USA DOE Stationary Energy Storage Program Review, Washington, DC Sept. 26-28, 2012 Dr. Imre Gyuk 1 2 Review of previous work 2.5M, ~30Wh/L, -5~50 o C Mixed-acid VRB Double Energy Density Extend temperature window Charge Discharge Charge Discharge Charge Discharge Catholyte: VO 2+ + Cl - + H 2 O - e VO 2 Cl + 2H + ε co =1.0 V Anolyte: V 3+ + e V 2+ ε ao =-0.25 Overall: VO 2+ + Cl

96

High Efficiency Particulate Air Filters  

NLE Websites -- All DOE Office Websites (Extended Search)

High Efficiency Particulate Air (HEPA) Filters High Efficiency Particulate Air (HEPA) Filters Home Standards DOE Workshops Nuclear Air Cleaning Conference Proceedings Qualified Filter List News Items Related Sites HEPA Related Lessons Learned Contact Us HSS Logo High Efficiency Particulate Air Filters The HEPA Filter web site provides a forum for informing and reporting department-wide activities related to filtration and ventilation issues with special reference to the High Efficiency Particulate Air (HEPA) Filters' use, inspection, and testing. This site contains essentials of DOE HEPA filter test program, procedures, requirements and quality assurance aspects applicable to HEPA filters used in DOE facilities. This site contains information about the DOE-accepted Filter Test Facility and its management, operation and quality assuranceprogram.

97

Filter assembly for metallic and intermetallic tube filters  

Science Conference Proceedings (OSTI)

A filter assembly (60) for holding a filter element (28) within a hot gas cleanup system pressure vessel is provided, containing: a filter housing (62), said filter housing having a certain axial length and having a peripheral sidewall, said sidewall defining an interior chamber (66); a one piece, all metal, fail-safe/regenerator device (68) within the interior chamber (66) of the filter housing (62) and/or extending beyond the axial length of the filter housing, said device containing an outward extending radial flange (71) within the filter housing for seating an essential seal (70), the device also having heat transfer media (72) disposed inside and screens (80) for particulate removal; one compliant gasket (70) positioned next to and above the outward extending radial flange of the fail-safe/regenerator device; and a porous metallic corrosion resistant superalloy type filter element body welded at the bottom of the metal fail-safe/regenerator device.

Alvin, Mary Anne (113 Lehr Ave., Pittsburgh, PA 15223); Lippert, Thomas E. (3205 Cambridge Rd., Murrysville, PA 15668); Bruck, Gerald J. (4469 Sardis Rd., Murrysville, PA 15668); Smeltzer, Eugene E. (R.D. 7, Box 267-I, Italy Rd., Export, PA 15632-9621)

2001-01-01T23:59:59.000Z

98

Ozone decomposing filter  

DOE Patents (OSTI)

In an improved ozone decomposing air filter carbon fibers are held together with a carbonized binder in a perforated structure. The structure is made by combining rayon fibers with gelatin, forming the mixture in a mold, freeze-drying, and vacuum baking.

Simandl, Ronald F. (Farragut, TN); Brown, John D. (Harriman, TN); Whinnery, Jr., LeRoy L. (Dublin, CA)

1999-01-01T23:59:59.000Z

99

Diffusion and Numerical Filters  

Science Conference Proceedings (OSTI)

Applications of low-pass filters or implicit diffusion are found to be extremely beneficial in a simple model problem that contains an oven-ordered advection scheme based on a symmetric stencil. In contrast, the effects are negative when either ...

William H. Raymond

1994-04-01T23:59:59.000Z

100

Ceramic HEPA Filter Program  

SciTech Connect

Potential benefits of ceramic filters in nuclear facilities: (1) Short term benefit for DOE, NRC, and industry - (a) CalPoly HTTU provides unique testing capability to answer questions for DOE - High temperature testing of materials, components, filter, (b) Several DNFSB correspondences and presentations by DNFSB members have highlighted the need for HEPA filter R and D - DNFSB Recommendation 2009-2 highlighted a nuclear facility response to an evaluation basis earthquake followed by a fire (aka shake-n-bake) and CalPoly has capability for a shake-n-bake test; (2) Intermediate term benefit for DOE and industry - (a) Filtration for specialty applications, e.g., explosive applications at Nevada, (b) Spin-off technologies applicable to other commercial industries; and (3) Long term benefit for DOE, NRC, and industry - (a) Across industry, strong desire for better performance filter, (b) Engineering solution to safety problem will improve facility safety and decrease dependence on associated support systems, (c) Large potential life-cycle cost savings, and (d) Facilitates development and deployment of LLNL process innovations to allow continuous ventilation system operation during a fire.

Mitchell, M A; Bergman, W; Haslam, J; Brown, E P; Sawyer, S; Beaulieu, R; Althouse, P; Meike, A

2012-04-30T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Particle Filtering in Geophysical Systems  

Science Conference Proceedings (OSTI)

The application of particle filters in geophysical systems is reviewed. Some background on Bayesian filtering is provided, and the existing methods are discussed. The emphasis is on the methodology, and not so much on the applications themselves. ...

Peter Jan van Leeuwen

2009-12-01T23:59:59.000Z

102

Strategic Plan Submitted to the Secretary  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4 Volume 1, Number 3 4 Volume 1, Number 3 In This Issue * Executive Order Update * $1 Million for Manhattan Project Preservation * 2004 DOE Cultural Resources Forum * ES&H Cultural Resources Update * FPO Site Visits * Oppenheimer and the Manhattan Project Event * Museum Notes * Save America's Treasures * Featured Photo: Oak Ridge, 1949 Strategic Plan Submitted to the Secretary The strategic plan for history and heritage resources that Secretary Abraham directed the Federal Preservation Officer to prepare has been submitted and is under review. Following the December 2, 2003, briefing at which the Secretary directed preparation of a plan to make recommendations for the full range of the Department's history and heritage resources, FPO Skip Gosling and Deputy FPO Terry Fehner put together a small planning

103

Submitting Organization Hongyou Fan Sandia National Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

 2007 R&D 100 Award Entry Form  Submitting Organization Hongyou Fan Sandia National Laboratories Advanced Materials Laboratory 1001 University Boulevard SE Albuquerque, NM 87106, USA 505-272-7128 (phone) 505-272-7336 (fax) hfan@sandia.gov AFFIRMATION: I affirm that all information submitted as a part of, or supplemental to, this entry is a fair and accurate represen- tation of this product. Submitter's signature_______________________________ Earl Stromberg Lockheed Martin Aeronautics Mail Zone 2893 PO Box 748 Fort Worth, TX 76101, USA 817-763-7376 (phone) 817-762-6911 (fax) Earl.W.Stromberg@lmco.com Self-Assembling Process for Fabricating Tailored Thin Films This simple, economical nanotechnology coating process enables the development of nanoparticle thin films

104

Quick-change filter cartridge  

DOE Patents (OSTI)

A quick-change filter cartridge. In sampling systems for measurement of airborne materials, a filter element is introduced into the sampled airstream such that the aerosol constituents are removed and deposited on the filter. Fragile sampling media often require support in order to prevent rupture during sampling, and careful mounting and sealing to prevent misalignment, tearing, or creasing which would allow the sampled air to bypass the filter. Additionally, handling of filter elements may introduce cross-contamination or exposure of operators to toxic materials. Moreover, it is desirable to enable the preloading of filter media into quick-change cartridges in clean laboratory environments, thereby simplifying and expediting the filter-changing process in the field. The quick-change filter cartridge of the present invention permits the application of a variety of filter media in many types of instruments and may also be used in automated systems. The cartridge includes a base through which a vacuum can be applied to draw air through the filter medium which is located on a porous filter support and held there by means of a cap which forms an airtight seal with the base. The base is also adapted for receiving absorbing media so that both particulates and gas-phase samples may be trapped for investigation, the latter downstream of the aerosol filter.

Rodgers, John C. (Santa Fe, NM); McFarland, Andrew R. (College Station, TX); Ortiz, Carlos A. (Bryan, TX)

1995-01-01T23:59:59.000Z

105

WIPP - How to submit a FOIA request  

NLE Websites -- All DOE Office Websites (Extended Search)

How to submit a Freedom of Information Act (FOIA) request FOIA requests to the U.S. Department of Energy Carlsbad Field Office (CBFO) may be submitted by request form, letter, fax, or e-mail. You may contact CBFO at the following address: George W. Hellstrom Freedom of Information Act/Privacy Act Public Liaison U.S. Department of Energy Carlsbad Field Office P.O. Box 3090 4021 National Parks Highway Carlsbad, New Mexico 88221-3090 foialiaison@ FOIA requests may be mailed or faxed to (505) 234-7025, e-mailed to the Freedom of Information Act /Privacy Act Public Liaison, or submitted electronically using the FOIA Request form. Clearly mark the envelope, fax, or e-mail "Freedom of Information Act request." Describe the records you are requesting as completely and accurately as possible, and provide your name, address, and telephone number. A telephone call between the requester and the FOIA contact person may be necessary to clarify a request and expedite processing time.

106

Filtered cathodic arc source  

DOE Patents (OSTI)

Disclosed is a continuous, cathodic arc ion source coupled to a macro-particle filter capable of separation or elimination of macro-particles from the ion flux produced by cathodic arc discharge. The ion source employs an axial magnetic field on a cathode (target) having tapered sides to confine the arc, thereby providing high target material utilization. A bent magnetic field is used to guide the metal ions from the target to the part to be coated. The macro-particle filter consists of two straight solenoids, end to end, but placed at 45{degrees} to one another, which prevents line-of-sight from the arc spot on the target to the parts to be coated, yet provides a path for ions and electrons to flow, and includes a series of baffles for trapping the macro-particles.

Falabella, S.; Sanders, D.M.

1992-12-31T23:59:59.000Z

107

Filtered cathodic arc source  

DOE Patents (OSTI)

A continuous, cathodic arc ion source coupled to a macro-particle filter capable of separation or elimination of macro-particles from the ion flux produced by cathodic arc discharge is described. The ion source employs an axial magnetic field on a cathode (target) having tapered sides to confine the arc, thereby providing high target material utilization. A bent magnetic field is used to guide the metal ions from the target to the part to be coated. The macro-particle filter consists of two straight solenoids, end to end, but placed at 45[degree] to one another, which prevents line-of-sight from the arc spot on the target to the parts to be coated, yet provides a path for ions and electrons to flow, and includes a series of baffles for trapping the macro-particles. 3 figures.

Falabella, S.; Sanders, D.M.

1994-01-18T23:59:59.000Z

108

Regenerable particulate filter  

DOE Patents (OSTI)

A method of making a three-dimensional lattice structure, such as a filter used to remove particulates from a gas stream, where the physical lattice structure is designed utilizing software simulation from pre-defined mass transfer and flow characteristics and the designed lattice structure is fabricated using a free-form fabrication manufacturing technique, where the periodic lattice structure is comprised of individual geometric elements.

Stuecker, John N. (Albuquerque, NM); Cesarano, III, Joseph (Albuquerque, NM); Miller, James E. (Albuquerque, NM)

2009-05-05T23:59:59.000Z

109

1.5 References Batzle, M. and Wang, Z., 1992, Seismic properties of pore fluids: Geophysics, Vol.  

E-Print Network (OSTI)

. 57, No. 11, p. 1396-1408. Batzle, M.L., Han, D., Wang, W., Wu, X., Ge, H., and Zhao, H., 1997, Fluid, USA, 348 pp. Chen, C.T., Chen, L.S., and Millero, F.J., 1978, Speed of sound in NaCl, MgCl2, Na2SO4-685. Hales, A.L., and Roberts, J.L., 1974, The Zoeppritz amplitude equations: more errors: Bulletin

110

Siphon filter assessment for Northern Ghana  

E-Print Network (OSTI)

The siphon filter is a household water filter developed by the Basic Water Needs Foundation based on the design of ceramic candle filters. The siphon filter is marketed under brand names CrystalPur and Tulip and is sold ...

Ziff, Sara Elizabeth

2009-01-01T23:59:59.000Z

111

Manuscript to be submitted to Atmos. Environ.  

NLE Websites -- All DOE Office Websites (Extended Search)

Secondary pollutants from ozone Secondary pollutants from ozone reactions with ventilation filters and degradation of filter media additives H. Destaillats, W. Chen, M.G. Apte, N. Li, M. Spears, J. Almosni, G. Brunner, J. Zhang, W.J. Fisk Environmental Energy Technologies Division March 2011 Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process

112

DOE Warns Manufacturers Who Submitted Incomplete Certification Reports |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Warns Manufacturers Who Submitted Incomplete Certification Warns Manufacturers Who Submitted Incomplete Certification Reports DOE Warns Manufacturers Who Submitted Incomplete Certification Reports February 2, 2010 - 1:53pm Addthis Washington, DC - The Department of Energy's Office of General Counsel has sent warning letters to 9 manufacturers or trade associations that submitted incomplete energy-efficiency test data to comply with DOE's energy-efficiency standards. This data was submitted during the 30-day grace period that ran from December 9, 2009, to January 8, 2010. Data for about 600,000 products was submitted. In this case, however, the data was incomplete. In light of the apparent attempt to comply with Department's regulations, the warning letters simply identify various substantive deficiencies in the data submitted, demand their expeditious

113

Coated x-ray filters  

DOE Patents (OSTI)

A radiation filter for filtering radiation beams of wavelengths within a preselected range of wavelengths comprises a radiation transmissive substrate and an attenuating layer deposited on the substrate. The attenuating layer may be deposited by a sputtering process or a vacuum process. Beryllium may be used as the radiation transmissive substrate. In addition, a second radiation filter comprises an attenuating layer interposed between a pair of radiation transmissive layers.

Steinmeyer, Peter A. (Farmington, NM)

1992-11-24T23:59:59.000Z

114

Coated x-ray filters  

DOE Patents (OSTI)

A radiation filter for filtering radiation beams of wavelengths within a preselected range of wavelengths comprises a radiation transmissive substrate and an attenuating layer deposited on the substrate. The attenuating layer may be deposited by a sputtering process or a vacuum process. Beryllium may be used as the radiation transmissive substrate. In addition, a second radiation filter comprises an attenuating layer interposed between a pair of radiation transmissive layers. 4 figs.

Steinmeyer, P.A.

1991-02-07T23:59:59.000Z

115

Specific filter designs for PFBC  

SciTech Connect

Bubbling bed PFBC technology is currently being demonstrated at commercial scale. Economic and performance improvements in these first generation type PFBC plants can be realized with the application of hot gas particulate filters. Both the secondary cyclone(s) and stack gas ESP(s) could be eliminated saving costs and providing lower system pressure losses. The cleaner gas (basically ash free) provided with the hot gas filter, also permits a wider selection of gas turbines with potentially higher performance. For these bubbling bed PFBC applications, the hot gas filter must operate at temperatures of 1580{degree}F and system pressures of 175 psia (conditions typical of the Tidd PFBC plant). Inlet dust loadings to the filter are estimated to be about 500 to 1000 ppm with mass mean particle diameters ranging from 1.5 to 3 {mu}m. For commercial applications typical of the 70 MW{sub e} Tidd PFBC demonstration unit, the filter must treat up to 56,600 acfm of gas flow. Scaleup of this design to about 320 MW{sub e} would require filtering over 160,000 acfm gas flow. For these commercial scale systems, multiple filter vessels are required. Thus, the filter design should be modular for scaling. An alternative to the bubbling bed PFBC is the circulating bed concept. In this process the hot gas filter will in general be exposed to higher operating temperatures (1650{degree}F) and significantly higher (factor of 10 or more) particle loading.

Lippert, T.E.; Bruck, G.J.; Newby, R.A.; Smeltzer, E.E.

1993-09-01T23:59:59.000Z

116

Explaining Collaborative Filtering Recommendations  

E-Print Network (OSTI)

Automated collaborative filtering (ACF) systems predict a person's affinity for items or information by connecting that person's recorded interests with the recorded interests of a community of people and sharing ratings between likeminded persons. However, current recommender systems are black boxes, providing no transparency into the working of the recommendation. Explanations provide that transparency, exposing the reasoning and data behind a recommendation. In this paper, we address explanation interfaces for ACF systems -- how they should be implemented and why they should be implemented. To explore how, we present a model for explanations based on the user's conceptual model of the recommendation process. We then present experimental results demonstrating what components of an explanation are the most compelling. To address why, we present experimental evidence that shows that providing explanations can improve the acceptance of ACF systems. We also describe some initial explor...

Jonathan Herlocker Joseph; Joseph A. Konstan; John Riedl

2000-01-01T23:59:59.000Z

117

Update on Novel Filter Development  

Science Conference Proceedings (OSTI)

Fabric filters (FFs) are highly effective particulate control devices installed at U.S. power plants to meet federal and state particulate emission requirements. This report describes FF operation at two coal-fired power plants, emphasizing tests of novel filter bag materials that may improve FF performance.

2009-02-26T23:59:59.000Z

118

PARS II Process Document SUBMITTING AND PROCESSING EMAIL AS OFFICIAL...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

PARS II Process Document SUBMITTING AND PROCESSING EMAIL AS OFFICIAL PROJECT ACTION APPROVAL DOCUMENTATION PURPOSE The purpose of this document is to describe the process and...

119

WebSubmit: Web-based Applications with Tcl  

Science Conference Proceedings (OSTI)

WebSubmit: Web-based Applications with Tcl ... The software is implemented as a collection of Tcl CGI scripts and a large body of Tcl support code. ...

120

Procedures for Submitting Documents for Posting on the DOE NEPA...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

for Submitting Documents for Posting on the DOE NEPA Website The Electronic DOE NEPA document archive is the only centralized electronic collection of DOE NEPA documents....

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Kansas City Plant submits productivity savings under share-in...  

NLE Websites -- All DOE Office Websites (Extended Search)

Kansas City Plant submits productivity savings under share-in-savings program | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation...

122

Advanced Vehicle Testing Activity: Oil Bypass Filter  

NLE Websites -- All DOE Office Websites (Extended Search)

Oil Bypass Filter to someone by E-mail Share Advanced Vehicle Testing Activity: Oil Bypass Filter on Facebook Tweet about Advanced Vehicle Testing Activity: Oil Bypass Filter on...

123

Flexible packet filtering: providing a rich toolbox  

Science Conference Proceedings (OSTI)

The BSD/OS IPFW packet filtering system is a well engineered, flexible kernel framework for filtering (accepting, rejecting, logging, or modifying) IP packets. IPFW uses the well understood, widely available Berkeley Packet Filter (BPF) system as the ...

Kurt J. Lidl; Deborah G. Lidl; Paul R. Borman

2002-02-01T23:59:59.000Z

124

Ground Clutter Canceling with a Regression Filter  

Science Conference Proceedings (OSTI)

This paper explores ground clutter filtering with a class of cancelers that use regression. Regression filters perform this task in a simple manner, resulting in similar or better performance than the fifth-order elliptic filter implemented in ...

Sebastin M. Torres; Dusan S. Zrnic

1999-10-01T23:59:59.000Z

125

Performance of ceramic membrane filters  

SciTech Connect

CeraMem Corp.`s ceramic-membrane coated, dead-end ceramic filters offer a promising alternative to ceramic candle filters providing long-term operational and reliability issues are resolved: regenerability of filter passages by back pulse cleaning, tolerance to alkali-containing combustion gas and thermal/chemical aging. ANL is responsible for analytical modeling of filtration and pulse cleaning operations, flow-through testing, and prediction of filter response to thermal cycling under realistic service conditions. A test apparatus was built to expose ceramic filter specimens to chemical environments simulating operation of pressurized fluidized bed and integrated gasification combined cycle plants. Four long-duration tests have been conducted in which 100-cpsi channel filters were exposed to ash collected downstream of the cyclone separator at the PFBC plant at Tidd. Results are discussed. Focus has now shifted to exposing the advanced candle filter specimens to reducing gas environments containing NaCl, H{sub 2}S, H{sub 2}O, and gasification ash.

Ahluwalia, R.K.; Im, K.H.; Geyer, H.K. [Argonne National Lab., IL (United States); Shelleman, D.L.; Tressler, R.E. [Pennsylvania State Univ., University Park, PA (United States)

1996-08-01T23:59:59.000Z

126

Advanced Vehicle Testing Activity: Oil Bypass Filter  

NLE Websites -- All DOE Office Websites (Extended Search)

Oil Bypass Filter The Idaho National Laboratory (INL) is evaluating oil bypass filter technology for the U.S. Department of Energy's (DOE's) Vehicle Technologies Office. Eight...

127

Status of granular bed filter development program  

SciTech Connect

The objective of this project was to design and develop moving bed granular filters and ceramic candle filters for particulate control from combined cycle systems. Results are described.

Wilson, K.B.; Haas, J.C.; Prudhomme, J.

1995-11-01T23:59:59.000Z

128

White Papers Submitted to the Technology Innovation Program  

E-Print Network (OSTI)

White Papers Submitted to the Technology Innovation Program interested parties to submit white papers describing an area of critical national need and how those needs-risk, high-reward R&D. White papers could discuss any area of critical national need of interest

Magee, Joseph W.

129

Efficient filtering of composite events  

Science Conference Proceedings (OSTI)

Event Notification Services (ENS) are used in various applications such as remote monitoring and control, stock tickers, traffic control, or facility management. The performance issues of the filtering of primitive events has been widely studied. However, ...

Annika Hinze

2003-07-01T23:59:59.000Z

130

Ensemble Filtering for Nonlinear Dynamics  

Science Conference Proceedings (OSTI)

A method for data assimilation currently being developed is the ensemble Kalman filter. This method evolves the statistics of the system by computing an empirical ensemble of sample realizations and incorporates measurements by a linear ...

Sangil Kim; Gregory L. Eyink; Juan M. Restrepo; Francis J. Alexander; Gregory Johnson

2003-11-01T23:59:59.000Z

131

Kalman FilterBased CMORPH  

Science Conference Proceedings (OSTI)

A Kalman filter (KF)-based Climate Prediction Center (CPC) morphing technique (CMORPH) algorithm is developed to integrate the passive microwave (PMW) precipitation estimates from low-Earth-orbit (LEO) satellites and infrared (IR) observations ...

Robert J. Joyce; Pingping Xie

2011-12-01T23:59:59.000Z

132

The Filtering of Meteorological Fields  

Science Conference Proceedings (OSTI)

A generalization of the popular Shapiro filters is described which allows the suppression of a broader band of frequencies near the sampling limit corresponding to two-grid-length waves. Applications to high-order finite difference models are ...

R. James Purser

1987-12-01T23:59:59.000Z

133

How to Submit a FOIA Request | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

to Submit a FOIA Request | National Nuclear Security Administration to Submit a FOIA Request | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > About Us > Our Operations > NNSA Office of General Counsel > Freedom of Information Act (FOIA) > How to Submit a FOIA Request How to Submit a FOIA Request FOIA requests to the NNSA/Office of the General Counsel may be submitted in

134

National Electric Transmission Congestion Study 2012 - How to Submit  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

National Electric Transmission Congestion Study 2012 - How to National Electric Transmission Congestion Study 2012 - How to Submit Comments National Electric Transmission Congestion Study 2012 - How to Submit Comments You may submit written comments to Congestionstudy2012@hq.doe.gov or by mail to: Office of Electricity Delivery and Energy Reliability, OE-20 U.S. Department of Energy 1000 Independence Avenue SW. Washington, DC 20585 The Department intends to use only data that is publicly available for this study. Accordingly, please do not submit information that you believe is or should be protected from public disclosure. DOE is responsible for the final determination concerning disclosure or nondisclosure of information submitted to DOE and for treating it in accordance with the DOE's Freedom of Information regulations (10 CFR 1004.11). All comments received by DOE

135

Submitting Environmental Impact Statements | Compliance and Enforcement | US EPA  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Submitting Environmental Impact Statements | Compliance and Enforcement | US EPA Submitting Environmental Impact Statements | Compliance and Enforcement | US EPA Jump to main content. National Environmental Policy Act (NEPA) Recent Additions | Contact Us Search: All EPA Compliance and Enforcement q You are here: EPA Home q Compliance and Enforcement q National Environmental Policy Act (NEPA) q Submitting Environmental Impact Statements Submitting Environmental Impact Statements q Amended EIS Filing System Guidelines (January 2011) q Where to Submit (or "File") an EIS q Filing an EIS--Draft, Final and Supplemental q EIS Filing Procedure for Continuity of Operations Plan (COOP) Events q Notice in the Federal Register q Time Periods Amended EIS Filing System Guidelines (January 2011)

136

Nitrogen atom energy distributions in a hollowcathode planar sputtering magnetron Zhehui Wang a , Samuel A. Cohen, D. N. Ruzic b , and M. J. Goeckner c  

E-Print Network (OSTI)

1 Nitrogen atom energy distributions in a hollow­cathode planar sputtering magnetron Zhehui Wang.O. Box 451, Princeton, NJ 08543 May 31, 1999 Abstract Energy distributions of N atoms in a hollow, University of Illinois c Varian Associates, Inc. #12; 2 atom energy distributions for atomic ions

137

Spatial distributions of tree species in a subtropical forest of China Lin Li, Zhongliang Huang, Wanhui Ye, Honglin Cao, Shiguang Wei, Zhigao Wang, Juyu Lian,  

E-Print Network (OSTI)

Spatial distributions of tree species in a subtropical forest of China Lin Li, Zhongliang Huang. Li, Z. Huang (huangzl@scib.ac.cn), W. Ye, H. Cao, S. Wei, Z. Wang and J. Lian, South China Botanical Garden, Chinese Academy of Science, Guangzhou, PR China. LL and SW also at: Guilin Univ. of Electronic

He, Fangliang

138

VHF Free-Free Beam High-Q Micromechanical Resonators Kun Wang, Yinglei Yu, Ark-Chew Wong, and Clark T.-C. Nguyen  

E-Print Network (OSTI)

VHF Free-Free Beam High-Q Micromechanical Resonators Kun Wang, Yinglei Yu, Ark-Chew Wong, and Clark Science University of Michigan Ann Arbor, Michigan 48109-2122 ABSTRACT Free-free beam, flexural and their associated losses are virtually eliminated from the design. Using this approach, free-free beam µmechanical

Nguyen, Clark T.-C.

139

Hydrogen From Bio-Derived LiquidsHydrogen From BioHydrogen From Bio--Derived LiquidsDerived Liquids Dave King, Yong Wang, PNNL  

E-Print Network (OSTI)

Dave King, Yong Wang, PNNL BILIWIG Meeting Laurel, Maryland November 6, 2007 #12;Innovation / Overview Brian James) #12;10/25/07: PNNL Complex with 8:1 Steam/Eth molar ratio and 75% PSA Recovery and 400C WGS

140

Designing Optimal Spectral Filters for Inverse Problems  

Science Conference Proceedings (OSTI)

Spectral filtering suppresses the amplification of errors when computing solutions to ill-posed inverse problems; however, selecting good regularization parameters is often expensive. In many applications, data are available from calibration experiments. ... Keywords: Bayes risk, Bayesian risk, Tikhonov, Wiener filter, empirical risk, filtering, ill-posed problem, image deblurring, machine learning, optimal design, optimal filtering, regularization, singular value decomposition, stochastic programming

Julianne Chung; Matthias Chung; Dianne P. O'Leary

2011-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Water washable stainless steel HEPA filter  

DOE Patents (OSTI)

The invention is a high efficiency particulate (HEPA) filter apparatus and system, and method for assaying particulates. The HEPA filter provides for capture of 99.99% or greater of particulates from a gas stream, with collection of particulates on the surface of the filter media. The invention provides a filter system that can be cleaned and regenerated in situ.

Phillips, Terrance D. (617 Chestnut Ct., Aiken, SC 29803)

2001-01-01T23:59:59.000Z

142

ESS 2012 Peer Review - Low Cost and Highly Selective Composite Membrane for Redox Flow Batteries - Fei Wang, EIC Laboratories  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Low Cost and Highly Selective Composite Membrane for Redox Flow Batteries Low Cost and Highly Selective Composite Membrane for Redox Flow Batteries Fei Wang, Dharmasena Peramunage, James M. Sylvia, and Monsy M. Jocob EIC Laboratories, Inc. 111 Downey Street, Norwood, MA 02062. www.eiclabs.com Identification of the Problem and Technical Approach Redox flow batteries (RFB) hold great promise for large scale electrochemical energy storage. A critical component of RFB is the membrane which separates anode and cathode compartments. The current state-of-the-art membrane, NAFION is too expensive, lacks selectivity, permitting leakage between anode and cathode electrolyte compartments. EIC is developing a novel bilayer, interpenetrating network membrane. Thin Nafion layer for anode side protection providing oxidative stability. The bulk part of the membrane consists of a block

143

Active dc filter for HVDC systems  

SciTech Connect

This article is a case history of the installation of active dc filters for high-performance, low-cost harmonics filtering at the Lindome converter station in the Konti-Skan 2 HVDC transmission link between Denmark and Sweden. The topics of the article include harmonics, interference, and filters, Lindome active dc filter, active dc filter design, digital signal processor, control scheme, protection and fault monitoring, and future applications.

Zhang, W. (Royal Inst. of Tech., Stockholm (Sweden)); Asplund, G.

1994-01-01T23:59:59.000Z

144

Filter systems for IGCC applications  

SciTech Connect

The objectives of this program were to identify metallic filter medium to be utilized in the Integrated Gasification Combined Cycle process (IGCC). In IGCC processes utilizing high efficiency desulfurizing technology, the traditional corrosion attack, sulfidation, is minimized so that metallic filters are viable alternatives over ceramic filters. Tampa Electric Company`s Polk Power Station is being developed to demonstrate Integrated Gasification Combined Cycle technology. The Pall Gas Solid Separation (GSS) System is a self cleaning filtration system designed to remove virtually all particulate matter from gas streams. The heart of the system is the filter medium used to collect the particles on the filter surface. The medium`s filtration efficiency, uniformity, permeability, voids volume, and surface characteristics are all important to establishing a permeable permanent cake. In-house laboratory blowback tests, using representative full scale system particulate, were used to confirm the medium selection for this project. Test elements constructed from six alloys were supplied for exposure tests: PSS 310SC (modified 310S alloy); PSS 310SC heat treated; PSS 310SC-high Cr; PSS 310SC-high Cr heat treated; PSS Hastelloy X; and PSS Hastelloy X heat treated.

Bevan, S.; Gieger, R.; Sobel, N.; Johnson, D.

1995-11-01T23:59:59.000Z

145

Radiant zone heated particulate filter  

DOE Patents (OSTI)

A system includes a particulate matter (PM) filter including an upstream end for receiving exhaust gas and a downstream end. A radiant zoned heater includes N zones, where N is an integer greater than one, wherein each of the N zones includes M sub-zones, where M is an integer greater than or equal to one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones, restricts exhaust gas flow in a portion of the PM filter that corresponds to the selected one of the N zones, and deactivates non-selected ones of the N zones.

Gonze, Eugene V [Pinckney, MI

2011-12-27T23:59:59.000Z

146

Westinghouse advanced particle filter system  

SciTech Connect

Integrated Gasification Combined Cycles (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) are being developed and demonstrated for commercial, power generation application. Hot gas particulate filters are key components for the successful implementation of IGCC and PFBC in power generation gas turbine cycles. The objective of this work is to develop and qualify through analysis and testing a practical hot gas ceramic barrier filter system that meets the performance and operational requirements of PFBC and IGCC systems. This paper updates the assessment of the Westinghouse hot gas filter design based on ongoing testing and analysis. Results are summarized from recent computational fluid dynamics modeling of the plenum flow during back pulse, analysis of candle stressing under cleaning and process transient conditions and testing and analysis to evaluate potential flow induced candle vibration.

Lippert, T.E.; Bruck, G.J.; Sanjana, Z.N.; Newby, R.A.

1994-10-01T23:59:59.000Z

147

Submit a Buy American Complaint | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Action Center » Submit a Buy American Complaint Action Center » Submit a Buy American Complaint Submit a Buy American Complaint Buy American Resources Section 1605 of the American Recovery and Reinvestment Act of 2009 sets forth the Buy American requirements for recipients of Recovery Act financial assistance, including EECBG recipients. If you have reason to believe that a vendor or grant recipient is violating the Buy American Requirements of the Recovery Act, which apply to iron, steel, or manufactured goods in a public works project funded by DOE, please provide the information that you have in support of that belief to BuyAmericanComplaints@hq.doe.gov. EERE Buy American Guidance Report an Appliance Regulation Violation Report Fraud to the IG Submit a Buy American Complaint FAQs Related to the Recovery Act

148

Robust Ensemble Filtering and Its Relation to Covariance Inflation in the Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

A robust ensemble filtering scheme based on the H? filtering theory is proposed. The optimal H? filter is derived by minimizing the supremum (or maximum) of a predefined cost function, a criterion different from the minimum variance used in the ...

Xiaodong Luo; Ibrahim Hoteit

2011-12-01T23:59:59.000Z

149

Particle Kalman Filtering: A Nonlinear Bayesian Framework for Ensemble Kalman Filters  

Science Conference Proceedings (OSTI)

This paper investigates an approximation scheme of the optimal nonlinear Bayesian filter based on the Gaussian mixture representation of the state probability distribution function. The resulting filter is similar to the particle filter, but is ...

Ibrahim Hoteit; Xiaodong Luo; Dinh-Tuan Pham

2012-02-01T23:59:59.000Z

150

Measurements of filter-cake properties  

SciTech Connect

The Pressurized Fluidized-Bed Combustion (PFBC) and Integrated Gasification Combined Cycle (IGCC) programs of the U.S. Department of Energy require filtration, at temperatures from about 600 to 900 {degrees}C, of fine particles of coal ash, char, or spent and unreacted sorbent from hot-gas streams. Achieving acceptable filter lifetimes requires solutions to or avoidance of, such problems as incomplete filter cleaning, re-entrainment (i.e., re-filtration) of particles from filter cleaning, and bridging of filter cake between adjacent filters. These and other potential problems may arise from the materials properties of filter cakes, from the filter-bank design, and from the mechanisms of filter cleaning. Avoiding re-entrainment requires that some bonding and agglomeration of particles occur in the cakes (so that the agglomerates from filter cleaning are too large to be re-entrained), but excessive agglomeration can produce poor cleaning or bridging. For both PFBC and IGCC applications, we can form filter cakes at process temperatures, gas compositions, and gas flow rates, and measure the gas-phase permeabilities, porosities, tensile strengths, and deformation coefficients of these filter cakes to determine their dependencies on temperature, reaction time, gas composition, particle compositions, and particle size distributions. Filter-cake shear strengths and flow factors can be measured for powders ``as received,`` for filter cakes that we have heated to process temperatures, or for powders heated in reactive gases to simulate gas-solid reactions in process filter cakes.

Smith, D.H.; Grimm, U.; Haddad, G.J.

1996-12-31T23:59:59.000Z

151

A rigid porous filter and filtration method  

DOE Patents (OSTI)

The present invention involves a porous rigid filter comprising a plurality of concentric filtration elements having internal flow passages and forming external flow passages there between. The present invention also involves a pressure vessel containing the filter for the removal of particulate from high pressure particulate containing gases, and further involves a method for using the filter to remove such particulate. The present filter has the advantage of requiring fewer filter elements due to the high surface area- to-volume ratio provided by the filter, requires a reduced pressure vessel size, and exhibits enhanced mechanical design properties, improved cleaning properties, configuration options, modularity and ease of fabrication.

Chiang, Ta-Kuan; Straub, Douglas, Straub L.; Dennis, Richard A.

1998-12-01T23:59:59.000Z

152

Image separation using particle filters  

Science Conference Proceedings (OSTI)

In this work, we will analyze the problem of source separation in the case of superpositions of different source images, which need to be extracted from a set of noisy observations. This problem occurs, for example, in the field of astrophysics, where ... Keywords: Bayesian source separation, Image separation, Non-stationary noise, Particle filtering, Sequential Monte Carlo

Mauro Costagli; Ercan Engin Kuruo?lu

2007-09-01T23:59:59.000Z

153

Dependable filtering: Philosophy and realizations  

Science Conference Proceedings (OSTI)

Digital content production and distribution has radically changed our business models. An unprecedented volume of supply is now on offer, whetted by the demand of millions of users from all over the world. Since users cannot be expected to browse through ... Keywords: Collaborative filtering, Sybil attack, link analysis, profile injection, social networks

Matteo Dell'Amico; Licia Capra

2010-12-01T23:59:59.000Z

154

ADVANCED HOT GAS FILTER DEVELOPMENT  

SciTech Connect

This report describes the fabrication and testing of continuous fiber ceramic composite (CFCC) based hot gas filters. The fabrication approach utilized a modified filament winding method that combined both continuous and chopped fibers into a novel microstructure. The work was divided into five primary tasks. In the first task, a preliminary set of compositions was fabricated in the form of open end tubes and characterized. The results of this task were used to identify the most promising compositions for sub-scale filter element fabrication and testing. In addition to laboratory measurements of permeability and strength, exposure testing in a coal combustion environment was performed to asses the thermo-chemical stability of the CFCC materials. Four candidate compositions were fabricated into sub-scale filter elements with integral flange and a closed end. Following the 250 hour exposure test in a circulating fluid bed combustor, the retained strength ranged from 70 t 145 percent of the as-fabricated strength. The post-test samples exhibited non-catastrophic failure behavior in contrast to the brittle failure exhibited by monolithic materials. Filter fabrication development continued in a filter improvement and cost reduction task that resulted in an improved fiber architecture, the production of a net shape flange, and an improved low cost bond. These modifications were incorporated into the process and used to fabricate 50 full-sized filter elements for testing in demonstration facilities in Karhula, Finland and at the Power Systems Development Facility (PSDF) in Wilsonville, AL. After 581 hours of testing in the Karhula facility, the elements retained approximately 87 percent of their as-fabricated strength. In addition, mechanical response testing at Virginia Tech provided a further demonstration of the high level of strain tolerance of the vacuum wound filter elements. Additional testing in the M. W. Kellogg unit at the PSDF has accumulated over 1800 hours of coal firing at temperatures of 760 C including a severe thermal upset that resulted in the failure of several monolithic oxide elements. No failures of any kind have been reported for the MTI CFCC elements in either of these test campaigns. Additional testing is planned at the M. W. Kellogg unit and Foster Wheeler unit at the PSDF over the next year in order to qualify for consideration for the Lakeland PCFB. Process scale-up issues have been identified and manufacturing plans are being evaluated to meet the needs of future demand.

RICHARD A. WAGNER

1998-09-04T23:59:59.000Z

155

Cordierite silicon nitride filters. Final report  

SciTech Connect

The objective of this project was to develop a silicon nitride based crossflow filter. This report summarizes the findings and results of the project. The project was phased with Phase I consisting of filter material development and crossflow filter design. Phase II involved filter manufacturing, filter testing under simulated conditions and reporting the results. In Phase I, Cordierite Silicon Nitride (CSN) was developed and tested for permeability and strength. Target values for each of these parameters were established early in the program. The values were met by the material development effort in Phase I. The crossflow filter design effort proceeded by developing a macroscopic design based on required surface area and estimated stresses. Then the thermal and pressure stresses were estimated using finite element analysis. In Phase II of this program, the filter manufacturing technique was developed, and the manufactured filters were tested. The technique developed involved press-bonding extruded tiles to form a filter, producing a monolithic filter after sintering. Filters manufactured using this technique were tested at Acurex and at the Westinghouse Science and Technology Center. The filters did not delaminate during testing and operated and high collection efficiency and good cleanability. Further development in areas of sintering and filter design is recommended.

Sawyer, J.; Buchan, B. [Acurex Environmental Corp., Mountain View, CA (United States); Duiven, R.; Berger, M. [Aerotherm Corp., Mountain View, CA (United States); Cleveland, J.; Ferri, J. [GTE Products Corp., Towanda, PA (United States)

1992-02-01T23:59:59.000Z

156

Koch Filter and DOW Teaming Profile  

NLE Websites -- All DOE Office Websites (Extended Search)

Koch Filter Corporation Dow Chemical Koch Filter Corporation Dow Chemical 4411-A Darien Street 2301 Brazosport Boulevard Houston, TX 77028 Freeport, TX 77541 Business: HVAC Filter Manufacturer Business: Chemical Manufacturer Bob Sheppard John Theile Regional Sales Manager Reliability Engineer Phone: 713-672-6550 Phone: 979-238-1894 Email: bobs@kochfilter.com Email: jptheile@dow.com Koch Filter saves Dow $156,000 by improving air flow to turbines Project Scope Koch Filter Corporation evaluated the turbine operation at a Dow Chemical facility. They determined that the gas turbine's air intake system was undersized and pre-filters had an initial resistance that was too high, causing the turbine to be "starved" for air. Koch replaced these filters with a better filter that

157

A Review of Recursive and Implicit Filters  

Science Conference Proceedings (OSTI)

Low- and high-pass traditional recursive and implicit filters are reviewed. Some similarities and differences between these two forms are illustrated. The use of recursive filters in signal processing is contrasted with the needs in meteorology. ...

William H. Raymond; Arthur Garder

1991-02-01T23:59:59.000Z

158

Filters for High Rate Pulse Processing  

E-Print Network (OSTI)

We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform, and second, orthogonality constraints are imposed on the filters, to reduce the filtering procedure's sensitivity to unknown baseline height and pulse tails. We analyze the proposed filters, predicting energy resolution under several scenarios, and apply the filters to high-rate pulse data from gamma-rays measured by a transition-edge-sensor microcalorimeter.

B. K. Alpert; R. D. Horansky; D. A. Bennett; W. B. Doriese; J. W. Fowler; A. S. Hoover; M. W. Rabin; J. N. Ullom

2012-12-07T23:59:59.000Z

159

Obstacles to High-Dimensional Particle Filtering  

Science Conference Proceedings (OSTI)

Particle filters are ensemble-based assimilation schemes that, unlike the ensemble Kalman filter, employ a fully nonlinear and non-Gaussian analysis step to compute the probability distribution function (pdf) of a systems state conditioned on a ...

Chris Snyder; Thomas Bengtsson; Peter Bickel; Jeff Anderson

2008-12-01T23:59:59.000Z

160

A Filter Algorithm for Nonlinear Semidefinite Programming  

E-Print Network (OSTI)

SSDP using a merit function (called Han penalty function) and a line search strategy. Motivated by ... functions with penalty terms which adjustment can be problematic. The filter ..... Otherwise, when (?(xk), f(xk)) is entered to the filter, either at...

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Diesel exhaust filter uses steel wool  

SciTech Connect

Researchers are experimenting with a diesel exhaust filter which can use either steel wool or wire mesh as the filter medium. By using alumina coated metal wool as the filter matrix, submicron-sized particulate emissions may be recovered. The particulate trapping efficiency of this kind of filter depends on the amount of alumina applied to it, and its physical dimensions. Surface area, which is a function of all of these, correlates well with trapping efficiency.

Not Available

1982-04-01T23:59:59.000Z

162

ELECTROSTATICALLY ENHANCED BARRIER FILTER COLLECTION  

SciTech Connect

This work was performed through the University of North Dakota (UND) Chemical Engineering Department with assistance from UND's Energy & Environmental Research Center. This research was undertaken in response to the U.S. Department of Energy Federal Technology Center Program Solicitation No. DE-PS26-99FT40479, Support of Advanced Coal Research at U.S. Universities and Colleges. Specifically, this research was in support of the UCR Core Program and addressees Topic 1, Improved Hot-Gas Contaminant and Particulate Removal Techniques, introducing an advanced design for particulate removal. Integrated gasification combined cycle (IGCC) offers the potential for very high efficiency and clean electric generation. In IGCC, the product gas from the gasifier needs to be cleaned of particulate matter to avoid erosion and high-temperature corrosion difficulties arising with the turbine blades. Current methods involve cooling the gases to {approx}100 C to condense alkalis and remove sulfur and particulates using conventional scrubber technology. This ''cool'' gas is then directed to a turbine for electric generation. While IGCC has the potential to reach efficiencies of over 50%, the current need to cool the product gas for cleaning prior to firing it in a turbine is keeping IGCC from reaching its full potential. The objective of the current project was to develop a highly reliable particulate collector system that can meet the most stringent turbine requirements and emission standards, can operate at temperatures above 1500 F, is applicable for use with all U.S. coals, is compatible with various sorbent injection schemes for sulfur and alkali control, can be integrated into a variety of configurations for both pressurized gasification and combustion, increases allowable face velocity to reduce filter system capital cost, and is cost-competitive with existing technologies. The collector being developed is a new concept in particulate control called electrostatically enhanced barrier filter collection (EBFC). This concept combines electrostatic precipitation (ESP) with candle filters in a single unit. Similar technology has been recently proven on a commercial scale for atmospheric applications, but needed to be tested at high temperatures and pressures. The synergy obtained by combining the two control technologies into a single system should actually reduce filter system capital and operating costs and make the system more reliable. More specifically, the ESP is expected to significantly reduce candle filter load and also to limit ash reintrainment, allowing for full recovery of baseline pressure drop during backpulsing of the filters.

John Erjavec; Michael D. Mann; Ryan Z. Knutson; Michael L. Swanson; Michael E. Collings

2003-06-01T23:59:59.000Z

163

Cluster ensembles in collaborative filtering recommendation  

Science Conference Proceedings (OSTI)

Recommender systems, which recommend items of information that are likely to be of interest to the users, and filter out less favored data items, have been developed. Collaborative filtering is a widely used recommendation technique. It is based on the ... Keywords: Cluster ensembles, Collaborative filtering, Recommender systems, Self-organizing maps, k-Means

Chih-Fong Tsai; Chihli Hung

2012-04-01T23:59:59.000Z

164

Sensitivity filtering from a continuum mechanics perspective  

Science Conference Proceedings (OSTI)

In topology optimization filtering is a popular approach for preventing numerical instabilities. This short note shows that the well-known sensitivity filtering technique, that prevents checkerboards and ensures mesh-independent designs in density-based ... Keywords: Filtering, Regularization, Topology optimization

Ole Sigmund; Kurt Maute

2012-10-01T23:59:59.000Z

165

DOE Marks Milestone in Submitting Yucca Mountain License Application |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Marks Milestone in Submitting Yucca Mountain License Marks Milestone in Submitting Yucca Mountain License Application DOE Marks Milestone in Submitting Yucca Mountain License Application June 3, 2008 - 12:51pm Addthis WASHINGTON, DC - The U.S. Department of Energy (DOE) today announced submittal of a license application (LA) to the U.S. Nuclear Regulatory Commission (NRC) seeking authorization to construct America's first repository for spent nuclear fuel and high-level radioactive waste at Yucca Mountain, Nevada. The 8,600 page application describes DOE's plan to safely isolate spent nuclear fuel and high-level radioactive waste in tunnels deep underground at Yucca Mountain, a remote ridge on federally controlled land in the Mojave Desert 90 miles northwest of Las Vegas. Currently, the waste is stored at 121 temporary locations in 39 states

166

Nonlinear image filtering within IDP++  

Science Conference Proceedings (OSTI)

IDP++, image and data processing in C++, is a set of a signal processing libraries written in C++. It is a multi-dimension (up to four dimensions), multi-data type (implemented through templates) signal processing extension to C++. IDP++ takes advantage of the object-oriented compiler technology to provide ``information hiding.`` Users need only know C, not C++. Signals or data sets are treated like any other variable with a defined set of operators and functions. We here some examples of the nonlinear filter library within IDP++. Specifically, the results of MIN, MAX median, {alpha}-trimmed mean, and edge-trimmed mean filters as applied to a real aperture radar (RR) and synthetic aperture radar (SAR) data set.

Lehman, S.K.; Wieting, M.G.; Brase, J.M.

1995-02-09T23:59:59.000Z

167

Filter for a drill string  

DOE Patents (OSTI)

A filter for a drill string comprises a perforated receptacle having an open end and a perforated end and first and second mounting surfaces are adjacent the open end. A transmission element is disposed within each of the first and second mounting surfaces. A capacitor may modify electrical characteristics of an LC circuit that comprises the transmission elements. The respective transmission elements are in communication with each other and with a transmission network integrated into the drill string. The transmission elements may be inductive couplers, direct electrical contacts, or optical couplers. In some embodiments of the present invention, the filter comprises an electronic component. The electronic component may be selected from the group consisting of a sensor, a router, a power source, a clock source, a repeater, and an amplifier.

Hall, David R. (Provo, UT); Pixton, David S. (Lehi, UT); Briscoe, Michael (Lehi, UT); McPherson, James (Sandy, UT)

2007-12-04T23:59:59.000Z

168

Westinghouse Advanced Particle Filter System  

SciTech Connect

Integrated Gasification Combined Cycles (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) are being developed and demonstrated for commercial, power generation application. Hot gas particulate filters are key components for the successful implementation of IGCC and PFBC in power generation gas turbine cycles. The objective of this work is to develop and qualify through analysis and testing a practical hot gas ceramic barrier filter system that meets the performance and operational requirements of PFBC and IGCC systems. This paper reports on the development and status of testing of the Westinghouse Advanced Hot Gas Particle Filter (W-APF) including: W-APF integrated operation with the American Electric Power, 70 MW PFBC clean coal facility--approximately 6000 test hours completed; approximately 2500 hours of testing at the Hans Ahlstrom 10 MW PCFB facility located in Karhula, Finland; over 700 hours of operation at the Foster Wheeler 2 MW 2nd generation PFBC facility located in Livingston, New Jersey; status of Westinghouse HGF supply for the DOE Southern Company Services Power System Development Facility (PSDF) located in Wilsonville, Alabama; the status of the Westinghouse development and testing of HGF`s for Biomass Power Generation; and the status of the design and supply of the HGF unit for the 95 MW Pinon Pine IGCC Clean Coal Demonstration.

Lippert, T.E.; Bruck, G.J.; Sanjana, Z.N.; Newby, R.A.; Bachovchin, D.M. [Westinghouse Electric Corp., Pittsburgh, PA (United States). Science and Technology Center

1996-12-31T23:59:59.000Z

169

A SINGLE-PARAMETER ADAPTIVE COMB FILTER  

E-Print Network (OSTI)

The study is concerned with a single-parameter adaptive comb filter (ACF), a multi-notch filter with periodically located nulls. The filter is suggested to retrieve a waveform modeled by superposition of harmonics, in particular, periodic non-sinusoidal signal. Using trigonometric constraints between the signal fundamental frequency and over tones results in a non-linear estimation problem. In the present study, the parameter adjustment relies on the extended Kalman filter scheme. Particularly, the 2, 3 and 4 notch ACF are derived and tested under different conditions. Given a multi-tone scenario, the ACF significantly outperforms common adaptive multi-notch filter.

Single-Parameter Adaptive Comb; Naum G. Chernoguz

2001-01-01T23:59:59.000Z

170

Filter for isotopic alteration of mercury vapor  

DOE Green Energy (OSTI)

A filter for enriching the .sup.196 Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The .sup.196 Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter.

Grossman, Mark W. (Belmont, MA); George, William A. (Gloucestor, MA)

1989-01-01T23:59:59.000Z

171

Filter for isotopic alteration of mercury vapor  

DOE Patents (OSTI)

A filter is described for enriching the [sup 196]Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The [sup 196]Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is, less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter. 9 figs.

Grossman, M.W.; George, W.A.

1989-06-13T23:59:59.000Z

172

Ceramic fiber ceramic matrix filter development  

SciTech Connect

The objectives of this project were to develop a novel type of candle filter based on a ceramic fiber-ceramic matrix composite material, and to extend the development to full-size, 60-mm OD by 1-meter-long candle filters. The goal is to develop a ceramic filter suitable for use in a variety of fossil energy system environments such as integrated coal gasification combined cycles (IGCC), pressurized fluidized-bed combustion (PFBC), and other advanced coal combustion environments. Further, the ceramic fiber ceramic matrix composite filter, hereinafter referred to as the ceramic composite filter, was to be inherently crack resistant, a property not found in conventional monolithic ceramic candle filters, such as those fabricated from clay-bonded silicon carbide. Finally, the adequacy of the filters in the fossil energy system environments is to be proven through simulated and in-plant tests.

Judkins, R.R.; Stinton, D.P. [Oak Ridge National Lab., TN (United States); Smith, R.G.; Fischer, E.M. [3M Company, St. Paul, MN (United States)

1994-09-01T23:59:59.000Z

173

Method and apparatus for filtering gas with a moving granular filter bed  

DOE Patents (OSTI)

A method and apparatus for filtering gas (58) with a moving granular filter bed (48) involves moving a mass of particulate filter material (48) downwardly through a filter compartment (35); tangentially introducing gas into the compartment (54) to move in a cyclonic path downwardly around the moving filter material (48); diverting the cyclonic path (58) to a vertical path (62) to cause the gas to directly interface with the particulate filter material (48); thence causing the gas to move upwardly through the filter material (48) through a screened partition (24, 32) into a static upper compartment (22) of a filter compartment for exodus (56) of the gas which has passed through the particulate filter material (48).

Brown, Robert C. (Ames, IA); Wistrom, Corey (Ames, IA); Smeenk, Jerod L. (Ames, IA)

2007-12-18T23:59:59.000Z

174

ADVANCED HOT GAS FILTER DEVELOPMENT  

SciTech Connect

Iron aluminide hot gas filters have been developed using powder metallurgy techniques to form seamless cylinders. Three alloys were short-term corrosion tested in simulated IGCC atmospheres with temperatures between 925 F and 1200 F with hydrogen sulfide concentrations ranging from 783 ppm{sub v} to 78,300 ppm{sub v}. Long-term testing was conducted for 1500 hours at 925 F with 78,300 ppm{sub v}. The FAS and FAL alloys were found to be corrosion resistant in the simulated environments. The FAS alloy has been commercialized.

Matthew R. June; John L. Hurley; Mark W. Johnson

1999-04-01T23:59:59.000Z

175

Two Wien Filter Spin Flipper  

SciTech Connect

A new 4pi spin manipulator composed of two Wien filters oriented orthogonally and separated by two solenoids has been installed at the CEBAF/Jefferson Lab photoinjector. The new spin manipulator is used to precisely set the electron spin direction at an experiment in any direction (in or out of plane of the accelerator) and provides the means to reverse, or flip, the helicity of the electron beam on a daily basis. This reversal is being employed to suppress systematic false asymmetries that can jeopardize challenging parity violation experiments that strive to measure increasingly small physics asymmetries [*,**,***]. The spin manipulator is part of the ultra-high vacuum polarized electron source beam line and has been successfully operated with 100keV and 130keV electron beam at high current (>100 microAmps). A unique feature of the device is that spin-flipping requires only the polarity of one solenoid magnet be changed. Performance characteristics of the Two Wien Filter Spin Flipper will be summarized.

Grames, J M; Benesch, J F; Clark, J; Hansknecht, J; Kazimi, R; Machie, D; Poelker, M; Stutzman, M L; Suleiman, R

2011-03-01T23:59:59.000Z

176

Widget:RRSectionFilter | Open Energy Information  

Open Energy Info (EERE)

RRSectionFilter RRSectionFilter Jump to: navigation, search This widget creates a filter tool, which will allow the user to filter the content displayed on the screen by RR Section region. It has been designed for use explicitly with the Geothermal Regulatory Roadmap home page. It is not designed for any other use. Parameters No paramteres Dependancies The Geothermal Regulatory Roadmap Sections page. Usage This Widget assumes the existence of HTML elements created by the Geothermal Regulatory Roadmap Sections page, and is called by that page using the following code: {{#Widget:RRSectionFilter}} Example For an example of this widget in use, please visit the page referenced above. (GRR/Sections) Retrieved from "http://en.openei.org/w/index.php?title=Widget:RRSectionFilter&oldid=65912

177

FILTER COMPONENT ASSESSMENT--CERAMIC CANDLES--  

SciTech Connect

Efforts at Siemens Westinghouse Power Corporation (SWPC) have been focused on development of hot gas filter systems as an enabling technology for advanced coal and biomass-based gas turbine power generation applications. SWPC has been actively involved in the development of advanced filter materials and component configuration, has participated in numerous surveillance programs characterizing the material properties and microstructure of field tested filter elements, and has undertaken extended, accelerated filter life testing programs. This report summarizes the results of SWPC's filter component assessment efforts, identifying the performance and stability of porous monolithic, fiber reinforced, and filament wound ceramic hot gas candle filters, potentially for {ge}3 years of viable pressurized fluidized-bed combustion (PFBC) service operating life.

M.A. Alvin

2004-04-23T23:59:59.000Z

178

Diesel particulate filter with zoned resistive heater  

Science Conference Proceedings (OSTI)

A diesel particulate filter assembly comprises a diesel particulate filter (DPF) and a heater assembly. The DPF filters a particulate from exhaust produced by an engine. The heater assembly has a first metallic layer that is applied to the DPF, a resistive layer that is applied to the first metallic layer, and a second metallic layer that is applied to the resistive layer. The second metallic layer is etched to form a plurality of zones.

Gonze, Eugene V [Pinckney, MI

2011-03-08T23:59:59.000Z

179

DC side filters for multiterminal HVDC systems  

SciTech Connect

Multiterminal HVDC systems present challenges in the specification and design of suitable dc side filtering. This document examines the existing experience and addresses the particular technical problems posed by multiterminal systems. The filtering requirements of small taps are discussed, as is the potential use of active filters. Aspects of calculation and design are considered and recommendations made to guide the planners and designers of future multiterminal schemes.

Shore, N.L.; Adamson, K.; Bard, P. [and others

1996-10-01T23:59:59.000Z

180

Zone heated diesel particulate filter electrical connection  

DOE Patents (OSTI)

An electrical connection system for a particulate filter is provided. The system includes: a particulate filter (PF) disposed within an outer shell wherein the PF is segmented into a plurality of heating zones; an outer mat disposed between the particulate filter and the outer shell; an electrical connector coupled to the outer shell of the PF; and a plurality of printed circuit connections that extend along the outer surface of the PF from the electrical connector to the plurality of heating zones.

Gonze, Eugene V. (Pinckney, MI); Paratore, Jr., Michael J. (Howell, MI)

2010-03-30T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Nuclear Filter Technology | Open Energy Information  

Open Energy Info (EERE)

located in Golden, CO. References Retrieved from "http:en.openei.orgwindex.php?titleNuclearFilterTechnology&oldid379255" Categories: Clean Energy Organizations Companies...

182

Microhydropower Conveyance and Filters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

it is funneled through a series of components that control its flow and filter out debris. These components include the headrace, forebay, and water conveyance (or channel,...

183

Indestructible Ultra-filtration: Ceramic HEPA Filters  

High Efficiency Particulate Air (HEPA) filters are widely used commercial products to remove airborne particulates from a gas stream in a gas process ...

184

Latest Filter Developments Increasing Existing Aluminium Smelter ...  

Science Conference Proceedings (OSTI)

Abstract Scope, With increasing electricity costs and falling metal commodity ... and the latest extension of Ad?Flow filter designs for even greater filtration...

185

Continuous air monitor filter changeout apparatus  

DOE Patents (OSTI)

An apparatus and corresponding method for automatically changing out a filter cartridge in a continuous air monitor. The apparatus includes: a first container sized to hold filter cartridge replacements; a second container sized to hold used filter cartridges; a transport insert connectively attached to the first and second containers; a shuttle block, sized to hold the filter cartridges that is located within the transport insert; a transport driver mechanism means used to supply a motive force to move the shuttle block within the transport insert; and, a control means for operating the transport driver mechanism.

Rodgers, John C. (Santa Fe, NM)

2008-07-15T23:59:59.000Z

186

Categorical Exclusion Determination Form It Submit by E-_  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

It Submit by E-_ It Submit by E-_ I'llail - ] Proposed Action Title: (0672- 1610) Eaton Corporation - Highly Efficient, Nea r-Isothermal Liquid-Piston Compressor fo r Low Cost At-Home Natural Gas Refueli ng Program or Field Office: Advanced Research Projects Agency - Energy LocationCs) CCity/County/State): Southfield, MI ; Eden Prairie, MN; Minneapolis, MN; and Milwaukee, WI Proposed Action Description: Funding will support efforts to develop a highly efficient, near isothermal liquid piston compressor for low cost, at-home natu ral gas refueling Proposed work will consist of: (1) develop and optimize a concept compressor design to achieve established performance and cost targets; (2) characterize and verify the expected performance for the compressor design; and (3) develop a compressor system prototype to test proof of

187

BESC Submits 32 Gene Disclosures for Patents | ORNL  

NLE Websites -- All DOE Office Websites (Extended Search)

News Careers Work with ORNL About ORNL Visiting ORNL Events and Conferences Highlights Success Stories Contact Us Index Home | ORNL | Highlights SHARE BESC submits 32 gene disclosures for future patents July 01, 2012 Plant geneticist Wellington Muchero examines phenotypic traits of Populus transgenic lines grown in a greenhouse. The Bioenergy Science Center (BESC) at Oak Ridge National Laboratory (ORNL) is preparing invention disclosures for 32 different genes that can help improve the yield of ethanol from cellulosic biomass. These genes or their variants function to overcome recalcitrance-difficulty in breaking down cellulosic biomass to release sugars. Several members of ORNL's Biosciences Division are submitting disclosures: 16 genes by Wellington Muchero, 10 genes by Udaya Kalluri, and

188

Page 1 of 4 Creating and Submitting a Key Request  

E-Print Network (OSTI)

of employees. Enter search criteria in the search fields available and select the down red arrow to filter the terms. #12;Page 3 of 4 13. On the Key Request Form - Room List windowpane, select Add New. 14 use the Select Drawing button after entering the building and floor to display the floor plan

Howitt, Ivan

189

Instructions for Submitting Documents to OpenNet  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Submitting Documents to OpenNet Submitting Documents to OpenNet Requesting an account to submit documents to OpenNet If you plan to load documents to OpenNet, you must have an OpenNet Logon Name and Password. If you don't already have one, go to the OpenNet web site at: http://www.osti.gov/opennet. 1. Click on the LOGIN link on the top right. 2. Read the information and check the "I agree..." box. 3. Click on the "Request data submission access..." link at the bottom of the page. 4. Fill out the form. One of the required fields is the Site Input Code field. This field provides a drop down list of DOE Sites. All users with the same Site Input Code can edit all the records for that site. If your Site Code is not in the list or you need a site code more specific to your office than those listed,

190

Transmit Matched Filter And Transmit Wiener Filter For The Downlink Of FDD DS-CDMA Systems  

E-Print Network (OSTI)

We present space-time transmit filters for FDD DS-CDMA systems based on partial channel state information, i. e. we do not take into account the channel coefficients. Although the FDD transmit zero-forcing filter seems to be the most intuitive approach, we focus on the FDD transmit matched filter and the FDD transmit Wiener filter. Similarly to the respective receive filters and TDD transmit filters, the FDD matched filter maximizes the desired signal portion at the receiver and is optimum for low signal-to-noise-ratio scenarios, whereas the FDD transmit Wiener filter takes into account the noise power at the receiver and is therefore able to find an optimum trade-off between signal maximization and interference suppression. Additionally, we show that the FDD transmit matched filter is a type of Eigenbeamforming. The simulation results reveal the excellent performance of the two FDD transmit filters. The FDD transmit Wiener filter even outperforms the TDD transmit matched filter for high signalto -noise-ratio which is based on the instantaneous channel properties.

M. Joham; K. Kusume; W. Utschick; J. A. Nossek

2002-01-01T23:59:59.000Z

191

Active imaging system with Faraday filter  

DOE Patents (OSTI)

An active imaging system has a low to medium powered laser transmitter and receiver wherein the receiver includes a Faraday filter with an ultranarrow optical bandpass and a bare (nonintensified) CCD camera. The laser is locked in the vicinity of the passband of the Faraday filter. The system has high sensitivity to the laser illumination while eliminating solar background.

Snyder, J.J.

1993-04-13T23:59:59.000Z

192

A random map implementation of implicit filters  

Science Conference Proceedings (OSTI)

Implicit particle filters for data assimilation generate high-probability samples by representing each particle location as a separate function of a common reference variable. This representation requires that a certain underdetermined equation be solved ... Keywords: Data assimilation, Implicit sampling, Particle filters, Sequential Monte Carlo

Matthias Morzfeld; Xuemin Tu; Ethan Atkins; Alexandre J. Chorin

2012-02-01T23:59:59.000Z

193

Gaussian mixture CPHD filter with gating technique  

Science Conference Proceedings (OSTI)

Cardinalized probability hypothesis density (CPHD) filter provides more accurate estimates of target number than the probability hypothesis density (PHD) filter, and hence, also of the states of targets. This additional capability comes at the price ... Keywords: Finite sets statistics, Gating, Gaussian mixture, Probability hypothesis density, Target tracking

Hongjian Zhang; Zhongliang Jing; Shiqiang Hu

2009-08-01T23:59:59.000Z

194

Mayday: Distributed Filtering for Internet Services  

E-Print Network (OSTI)

Mayday is an architecture that combines overlay networks with lightweight packet filtering to defend against denial of service attacks. The overlay nodes perform client authentication and protocol verification, and then relay the requests to a protected server. The server is protected from outside attack by simple packet filtering rules that can be efficiently deployed even in backbone routers. Mayday generalizes

David G. Andersen

2003-01-01T23:59:59.000Z

195

A ZVS cycloconverter based series active filter  

Science Conference Proceedings (OSTI)

A new zero voltage switching (ZVS) series active filter (SAF) is proposed. The circuit includes a phase shift based PWM full-bridge inverter. A cycloconverter is used to control the polarity of output voltage pulses of mentioned inverter. Combination ... Keywords: series active filter, zero voltage switching

M. Tarafdar Haque; M. Sabahi

2006-03-01T23:59:59.000Z

196

Condensate Filter Demineralizer Performance Improvement Program  

Science Conference Proceedings (OSTI)

Upgrading condensate filter demineralizer (CFD) performance poses a complex, challenging utility task. This report summarizes the major factors that impact CFD performance and defines a comprehensive improvement program. In specific, the report discusses hardware, filter media, and operating practices, describing each area in terms of the underlying technology, approach to optimization, and utility experience.

1997-07-21T23:59:59.000Z

197

Clean Cities: Submitting Project Ideas for the Clean Cities National Parks  

NLE Websites -- All DOE Office Websites (Extended Search)

Submitting Project Ideas for the Clean Submitting Project Ideas for the Clean Cities National Parks Initiative to someone by E-mail Share Clean Cities: Submitting Project Ideas for the Clean Cities National Parks Initiative on Facebook Tweet about Clean Cities: Submitting Project Ideas for the Clean Cities National Parks Initiative on Twitter Bookmark Clean Cities: Submitting Project Ideas for the Clean Cities National Parks Initiative on Google Bookmark Clean Cities: Submitting Project Ideas for the Clean Cities National Parks Initiative on Delicious Rank Clean Cities: Submitting Project Ideas for the Clean Cities National Parks Initiative on Digg Find More places to share Clean Cities: Submitting Project Ideas for the Clean Cities National Parks Initiative on AddThis.com... Goals & Accomplishments

198

Automatic tuning for linearly tunable filter  

E-Print Network (OSTI)

A new tuning scheme for linearly tunable high-Q filters is proposed. The tuning method is based on using the phase information for both frequency and Q factor tuning. There is no need to find out the relationship between a filter's passband magnitude and Q. A gm-C biquadratic filter is designed to demonstrate the proposed tuning circuitry. The project includes a phase locked loop (PLL) based frequency tuning loop, reference clock generator, and differential difference amplifier (DDA) for dealing with frequency and Q factor tuning loop and linearly tunable second order gm-C bandpass filter. Simulation results for a 10 MHz prototype filter using AMI 0.5?m process is presented. The chip testing results show that the automatic frequency tuning error is 2.5% for the 10 MHz case.

Huang, Sung-Ling

2003-05-01T23:59:59.000Z

199

Thermovoltaic semiconductor device including a plasma filter  

DOE Patents (OSTI)

A thermovoltaic energy conversion device and related method for converting thermal energy into an electrical potential. An interference filter is provided on a semiconductor thermovoltaic cell to pre-filter black body radiation. The semiconductor thermovoltaic cell includes a P/N junction supported on a substrate which converts incident thermal energy below the semiconductor junction band gap into electrical potential. The semiconductor substrate is doped to provide a plasma filter which reflects back energy having a wavelength which is above the band gap and which is ineffectively filtered by the interference filter, through the P/N junction to the source of radiation thereby avoiding parasitic absorption of the unusable portion of the thermal radiation energy.

Baldasaro, Paul F. (Clifton Park, NY)

1999-01-01T23:59:59.000Z

200

NUCLEAR RADIATION DOSIMETER USING COMPOSITE FILTER AND A SINGLE ELEMENT FILTER  

DOE Patents (OSTI)

A nuclear radiation dosimeter is described that uses, in combination, a composite filter and a single element filter. The composite filter contains a plurality of comminuted metals having K-edges evenly distributed over the energy range of interest and the quantity of each of the metals is selected to result in filtering in an amount inversely proportional to the sensitivity of the film in the range over l00 kev. A copper filter is used that has a thickness to contribute the necessary additional correction in the interval between 40 and 100 kev. (AEC)

Storm, E.; Shlaer, S.

1964-04-21T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Microwave-Regenerated Diesel Exhaust Particulate Filter  

Science Conference Proceedings (OSTI)

Development of a microwave-regenerated particulate filter system has evolved from bench scale work to actual diesel engine experimentation. The filter system was initially evaluated on a stationary mounted 1.2-L diesel engine and was able to remove a significant amount of carbon particles from the exhaust. The ability of the microwave energy to regenerate or clean the filter was also demonstrated on this engine under idle conditions. Based on the 1.2-L experiments, improvements to the filter design and materials were implemented and the system was re-evaluated on a vehicle equipped with a 7.3-L diesel engine. The 7.3-L engine was selected to achieve heavy filter loading in a relatively short period of time. The purpose of these experiments was to evaluate filter-loading capacity, power requirements for regeneration, and filter regeneration efficiency. A more detailed evaluation of the filter was performed on a stationary mounted 1.9-L diesel engine. The effect of exhaust flow rate, loading, transients, and regeneration on filter efficiency was evaluated with this setup. In addition, gaseous exhaust emissions were investigated with and without an oxidation catalyst on the filter cartridge during loading and regeneration. (SAE Paper SAE-2001-01-0903 2001 SAE International. This paper is published on this website with permission from SAE International. As a user of this website, you are permitted to view this paper on-line, download this pdf file and print one copy of this paper at no cost for your use only. The downloaded pdf file and printout of this SAE paper may not be copied, distributed or forwarded to others or for the use of others.)

Nixdorf, Richard D. (Industrial Ceramic Solution, LLC); Green, Johney Boyd; Story, John M.; Wagner, Robert M. (Oak Ridge National Laboratory)

2001-03-05T23:59:59.000Z

202

Final Report: Fan Filter Unit Project  

NLE Websites -- All DOE Office Websites (Extended Search)

61684 61684 Demonstration of Advanced Filtration Technologies: Developing Energy-rebate Criteria through Performing Standard Laboratory Tests and Statistical Analyses Final Report (LBNL- 61684) To California Energy Commission 2007 Tengfang Xu and Duo Wang 2 Disclaimer This document was prepared as an account of work sponsored by the United States Government and California Energy Commission. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor California Energy Commission, nor The Regents of the University of California, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or

203

Xiaohua (Joshua) Wang resume  

NLE Websites -- All DOE Office Websites (Extended Search)

New Jersey Institute of Technology; Newark, New Jersey, 2002 MS, Fluid Mechanics, Tsinghua University; Beijing, China, 1996 BS, Engineering Mechanics, Tsinghua...

204

Pu WangReference  

E-Print Network (OSTI)

[1] O. Dousse and P. Thiran, Connectivity vs capacity in dense ad- hoc networks, Proc. INFOCOM 2004. [2] P. Gupta and P. R. Kumar, Critical power for asymptotic connectivity in

Pu Wang Reference; O. Dousse; P. Mannersalo; P. Thiran; O. Hggstrm; Y. Peres; J. Steif; Dynamic Percolation; Pu Wang

2007-01-01T23:59:59.000Z

205

Jian Wang | BNL  

NLE Websites -- All DOE Office Websites (Extended Search)

focuses on the processes that control the properties and evolutions of atmospheric aerosols and the interactions between aerosols and clouds. The main topics are: (1) the...

206

Potential for Hepa filter damage from water spray systems in filter plenums  

SciTech Connect

The water spray systems in high efficiency particulate air (HEPA) filter plenums that are used in nearly all Department of Energy (DOE) facilities for protection against fire was designed under the assumption that the HEPA filters would not be damaged by the water sprays. The most likely scenario for filter damage involves filter plugging by the water spray, followed by the fan blowing out the filter medium. A number of controlled laboratory tests that were previously conducted in the late 1980s are reviewed in this paper to provide a technical basis for the potential HEPA filter damage by the water spray system in HEPA filter plenums. In addition to the laboratory tests, the scenario for HEPA filter damage during fires has also occurred in the field. Afire in a four-stage, HEPA filter plenum at Rocky Flats in 1980 caused the first three stages of HEPA filters to blow out of their housing and the fourth stage to severely bow. Details of this recently declassified fire are presented in this paper. Although these previous findings suggest serious potential problems exist with the current water spray system in filter plenum , additional studies are required to confirm unequivocally that DOE`s critical facilities are at risk.

Bergman, W.; Fretthold, J.K.; Slawsld, J.W.

1997-01-01T23:59:59.000Z

207

Advanced Energy-Efficient Filtration: Fan Filter Unit  

E-Print Network (OSTI)

Efficient Fan- Filter Units, Proceedings of SEMI TechnicalFor Evaluating Fan-Filter Unit Performance Applications inPerformance of Fan-Filter Units, Version 1.2 (2004, public

Xu, Tengfang

2005-01-01T23:59:59.000Z

208

Advanced Energy-Efficient Filtration: Fan Filter Unit  

E-Print Network (OSTI)

Cleanrooms: Energy Efficient Fan- Filter Units, ProceedingsStandard Method For Evaluating Fan-Filter Unit Performance Energy Performance of Fan-Filter Units, Version 1.2 (2004,

Xu, Tengfang

2005-01-01T23:59:59.000Z

209

A Unification of Ensemble Square Root Kalman Filters  

Science Conference Proceedings (OSTI)

In recent years, several ensemble-based Kalman filter algorithms have been developed that have been classified as ensemble square root Kalman filters. Parallel to this development, the singular evolutive interpolated Kalman (SEIK) filter has ...

Lars Nerger; Tijana Janji?; Jens Schrter; Wolfgang Hiller

2012-07-01T23:59:59.000Z

210

The DolphChebyshev Window: A Simple Optimal Filter  

Science Conference Proceedings (OSTI)

Analyzed data for numerical prediction can be effectively initialized by means of a digital filter. Computation time is reduced by using an optimal filter. The construction of optimal filters involves the solution of a nonlinear minimization ...

Peter Lynch

1997-04-01T23:59:59.000Z

211

Automating data aggregation for collaborative filtering in Ruby on Rails  

E-Print Network (OSTI)

Collaborative filtering and information filtering are tried and proven methods of utilizing aggregated data about a website's users to provide catered content. Passive filters are one subset of such algorithms that utilize ...

Malconian, Daniel R

2008-01-01T23:59:59.000Z

212

TESTING OF THE DUAL ROTARY FILTER SYSTEM  

SciTech Connect

The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek rotary microfilter (RMF) units to determine the behavior of a multiple filter system. Both units were successfully controlled by a control scheme written in DELTA-V architecture by Savannah River Remediation (SRR) Process Control Engineering personnel. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The installation configuration originally proposed by the Small Colum Ion Exchange (SCIX) project of independent filter and motor mountings may be susceptible to vibration. Significant stiffening of the filter and motor mounts was required to minimize the vibration. Alignment of the motor to the filter was a challenge in this test configuration. The deployment configuration must be easy to manipulate and allow for fine adjustment. An analysis of the vibration signature of the test system identified critical speeds. Whether it corresponds to the resonance frequency of a rotor radial vibration mode that was excited by rotor unbalance is uncertain based upon the measurements. A relative motion series should be completed on the filter with the final shaft configuration to determine if the resonances exist in the final filter design. The instrumentation selected for deployment, including the concentrate discharge control valve and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual RMF system. The one area of concern with the instrumentation was the condition resulting when the filtrate flow meter operated with less than three gpm. This low flow was at the lower range of performance for the flow meter. This should not be an issue in deployment where the desired flow rate will be within the normal operating range of the meter. Testing demonstrated that the use of a flexible line for the filtrate discharge is highly desired at the outlet of the rotary union to transition to the system piping. Isolating the vibration from the rotary union will significantly improve the lifetime of the seals. Methods to monitor and isolate individual filters should be considered during deployment. The ability to diagnose issues and isolate individual filters would allow isolation prior to failure. Thus, filters may be cleaned or repaired instead of requiring complete replacement if the condition were to continue unnoticed. Isolating the filtrate line of each filter during startup will minimize the premature buildup of solids on the filter disks. Several tests have shown that the method of filter startup can improve performance lifetime of the filters. The installation must factor in an air inlet for the draining of a filter that does not involve a reverse flow through the filter disks. The reverse flow may cause deformation of the disks or may damage other components of the filters themselves.

Herman, D.; Fowley, M.; Stefanko, D.

2011-08-29T23:59:59.000Z

213

Multiple stage multiple filter hydrate store  

DOE Patents (OSTI)

An improved hydrate store for a metal halogen battery system is disclosed which employs a multiple stage, multiple filter means for separating the halogen hydrate from the liquid used in forming the hydrate. The filter means is constructed in the form of three separate sections which combine to substantially cover the interior surface of the store container. Exit conduit means is provided in association with the filter means for transmitting liquid passing through the filter means to a hydrate former subsystem. The hydrate former subsystem combines the halogen gas generated during the charging of the battery system with the liquid to form the hydrate in association with the store. Relief valve means is interposed in the exit conduit means for controlling the operation of the separate sections of the filter means, such that the liquid flow through the exit conduit means from each of the separate sections is controlled in a predetermined sequence. The three separate sections of the filter means operate in three discrete stages to provide a substantially uniform liquid flow to the hydrate former subsystem during the charging of the battery system. The separation of the liquid from the hydrate causes an increase in the density of the hydrate by concentrating the hydrate along the filter means. 7 figs.

Bjorkman, H.K. Jr.

1983-05-31T23:59:59.000Z

214

Moving Granular Bed Filter Development Program  

SciTech Connect

The granular bed filter was developed through low pressure, high temperature (1600{degrees}F) testing in the late 1970`s and early 1980`s`. Collection efficiencies over 99% were obtained. In 1988, high pressure, high temperature testing was completed at New York University, Westbury, N.Y., utilizing a coal-fired pressurized, fluidized bed combustor. High particulate removal efficiencies were confirmed as it was shown that both New Source Performance Standards and turbine tolerance limits could be met. The early scale-up work of the granular bed filter indicated potential limitations due to size, cost, and mechanical complexity. These limitations were addressed in the present program by utilizing the information gained from the filter development up through the NYU test program to reassess the commercial approach. Two studies were chosen for developing conceptual designs and cost estimates of the commercial sized filters. One is the economic study of the 250 MWe, second generation pressurized fluidized bed combustion plant defined by Foster Wheeler. This plant originally included cross-flow filters for hot gas cleanup. The other plant under study is a 100 MWe, airblown KRW gasifier. A cross-flow inter was utilized for gas stream cleanup in this study also. Granular bed and ceramic candle filters were substituted for the cross-flow filters in both these plants, and the resulting cost of electricity (COE) is compared.

Wilson, K.B.; Haas, J.C.; Eshelman, M.B.

1992-11-01T23:59:59.000Z

215

Moving Granular Bed Filter Development Program  

SciTech Connect

The granular bed filter was developed through low pressure, high temperature (1600[degrees]F) testing in the late 1970's and early 1980's'. Collection efficiencies over 99% were obtained. In 1988, high pressure, high temperature testing was completed at New York University, Westbury, N.Y., utilizing a coal-fired pressurized, fluidized bed combustor. High particulate removal efficiencies were confirmed as it was shown that both New Source Performance Standards and turbine tolerance limits could be met. The early scale-up work of the granular bed filter indicated potential limitations due to size, cost, and mechanical complexity. These limitations were addressed in the present program by utilizing the information gained from the filter development up through the NYU test program to reassess the commercial approach. Two studies were chosen for developing conceptual designs and cost estimates of the commercial sized filters. One is the economic study of the 250 MWe, second generation pressurized fluidized bed combustion plant defined by Foster Wheeler. This plant originally included cross-flow filters for hot gas cleanup. The other plant under study is a 100 MWe, airblown KRW gasifier. A cross-flow inter was utilized for gas stream cleanup in this study also. Granular bed and ceramic candle filters were substituted for the cross-flow filters in both these plants, and the resulting cost of electricity (COE) is compared.

Wilson, K.B.; Haas, J.C.; Eshelman, M.B.

1992-01-01T23:59:59.000Z

216

Oil Bypass Filter Technology Evaluation - Fourth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

ABSTRACT This fourth Oil Bypass Filter Technology Evaluation report details the ongoing fleet evaluation of an oil bypass filter technology by the Idaho National Engineering and...

217

The Investigation of Minor Element Additions on Oxide Filtering and ...  

Science Conference Proceedings (OSTI)

USA. Summary. Effects of minor element additions on filtering were studied ... demand. An understanding of the phenomena involved in the filtering process.

218

U-252: Barracuda Web Filter Input Validation Flaws Permit Cross...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2: Barracuda Web Filter Input Validation Flaws Permit Cross-Site Scripting Attacks U-252: Barracuda Web Filter Input Validation Flaws Permit Cross-Site Scripting Attacks September...

219

Performance evaluation of diesel particulate filters on heavy duty vehicles.  

E-Print Network (OSTI)

??Diesel particulate filters, or DPFs, are exhaust aftertreatment devices used to reduce exhaust emissions from diesel powered vehicles. Typical designs have a wall flow filter (more)

Rosepiler, Stephen G.

2003-01-01T23:59:59.000Z

220

Filter:Incentives by Efficiency or Renewable | Open Energy Information  

Open Energy Info (EERE)

Efficiency or Renewable Jump to: navigation, search This filter covers the property IncentiveEnergyCat. Retrieved from "http:en.openei.orgwindex.php?titleFilter:Incentivesby...

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Electro-optical tunable birefringent filter  

DOE Patents (OSTI)

An electrically tunable Lyot type filter is a Lyot that include one or more filter elements. Each filter element may have a planar, solid crystal comprised of a material that exhibits birefringence and is electro-optically active. Transparent electrodes may be coated on each face of the crystal. An input linear light polarizer may be located on one side of the crystal and oriented at 45 degrees to the optical axis of the birefringent crystal. An output linear light polarizer may be located on the other side of the crystal and oriented at -45 degrees with respect to the optical axis of the birefringent crystal. When an electric voltage is applied between the electrodes, the retardation of the crystal changes and so does the spectral transmission of the optical filter.

Levinton, Fred M. (Princeton, NJ)

2012-01-31T23:59:59.000Z

222

A filter model for mobile processes  

Science Conference Proceedings (OSTI)

This paper presents a filter model for ?-calculus and shows its full abstraction with respect to a may operational semantics. The model is introduced in the form of a type assignment system. Types are related by a preorder that mimics ...

Ferruccio Damiani; Mariangiola Dezani-Ciancaglini; Paola Giannini

1999-02-01T23:59:59.000Z

223

An improved visualization of diesel particulate filter/  

E-Print Network (OSTI)

The prevalence of diesel particulate filters (DPF) is increasing as emissions standards worldwide evolve to match current technologies. Since the first application of DPFs in the 1980's, PM trapping effectiveness has ...

Boehm, Kevin (Kevin W.)

2011-01-01T23:59:59.000Z

224

Advanced filters and components for power applications  

E-Print Network (OSTI)

The objective of this thesis is to improve the high frequency performance of components and filters by better compensating the parasitic effects of practical components. The main application for this improvement is in ...

Neugebauer, Timothy Carl, 1975-

2004-01-01T23:59:59.000Z

225

Filtering Turbulent Sparsely Observed Geophysical Flows  

Science Conference Proceedings (OSTI)

Filtering sparsely turbulent signals from nature is a central problem of contemporary data assimilation. Here, sparsely observed turbulent signals from nature are generated by solutions of two-layer quasigeostrophic models with turbulent cascades ...

John Harlim; Andrew J. Majda

2010-04-01T23:59:59.000Z

226

Optimal Filtering of AC Output Anemometers  

Science Conference Proceedings (OSTI)

The output of pulsed and AC output anemometers suffer from discretization noise when such anemometers are sampled at fast rates (>1 Hz). This paper describes the construction of an optimal filter designed to reduce this noise. By comparing the ...

J. C. Barnard; L. L. Wendell; V. R. Morris

1998-12-01T23:59:59.000Z

227

Dissipative Cryogenic Filters with Zero DC Resistance  

SciTech Connect

The authors designed, implemented and tested cryogenic RF filters with zero DC resistance, based on wires with a superconducting core inside a resistive sheath. The superconducting core allows low frequency currents to pass with negligible dissipation. Signals above the cutoff frequency are dissipated in the resistive part due to their small skin depth. The filters consist of twisted wire pairs shielded with copper tape. Above approximately 1 GHz, the attenuation is exponential in {radical}{omega}, as typical for skin depth based RF filters. By using additional capacitors of 10 nF per line, an attenuation of at least 45 dB above 10 MHz can be obtained. Thus, one single filter stage kept at mixing chamber temperature in a dilution refrigerator is sufficient to attenuate room temperature black body radiation to levels corresponding to 10 mK above about 10 MHz.

Bluhm, Hendrik; Moler, Kathryn A.; /Stanford U., Appl. Phys. Dept

2008-04-22T23:59:59.000Z

228

Maximum Likelihood Ensemble Filter: Theoretical Aspects  

Science Conference Proceedings (OSTI)

A new ensemble-based data assimilation method, named the maximum likelihood ensemble filter (MLEF), is presented. The analysis solution maximizes the likelihood of the posterior probability distribution, obtained by minimization of a cost ...

Milija Zupanski

2005-06-01T23:59:59.000Z

229

GLOBAL CONVERGENCE OF SLANTING FILTER METHODS FOR ...  

E-Print Network (OSTI)

After the iteration is completed, this entry will become permanent in the filter only if the iteration doe not produce a decrease in fo. In particular, note that if h(x()...

230

Plasma Mass Filters For Nuclear Waste Reprocessing  

SciTech Connect

Practical disposal of nuclear waste requires high-throughput separation techniques. The most dangerous part of nuclear waste is the fission product, which contains the most active and mobile radioisotopes and produces most of the heat. We suggest that the fission products could be separated as a group from nuclear waste using plasma mass filters. Plasmabased processes are well suited to separating nuclear waste, because mass rather than chemical properties are used for separation. A single plasma stage can replace several stages of chemical separation, producing separate streams of bulk elements, fission products, and actinoids. The plasma mass filters may have lower cost and produce less auxiliary waste than chemical processing plants. Three rotating plasma configurations are considered that act as mass filters: the plasma centrifuge, the Ohkawa filter, and the asymmetric centrifugal trap.

Abraham J. Fetterman and Nathaniel J. Fisch

2011-05-26T23:59:59.000Z

231

Analysis Scheme in the Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

This paper discusses an important issue related to the implementation and interpretation of the analysis scheme in the ensemble Kalman filter. It is shown that the observations must be treated as random variables at the analysis steps. That is, ...

Gerrit Burgers; Peter Jan van Leeuwen; Geir Evensen

1998-06-01T23:59:59.000Z

232

Mayday: distributed filtering for internet services  

Science Conference Proceedings (OSTI)

Mayday is an architecture that combines overlay networks with lightweight packet filtering to defend against denial of service attacks. The overlay nodes perform client authentication and protocol verification, and then relay the requests to a protected ...

David G. Andersen

2003-03-01T23:59:59.000Z

233

Fail Save Shut Off Valve for Filtering Systems Employing Candle Filters  

NLE Websites -- All DOE Office Websites (Extended Search)

Fail Save Shut Off Fail Save Shut Off Valve for Filtering Systems Employing Candle Filters Opportunity The Department of Energy's National Energy Technology Laboratory (NETL) is seeking licensing partners interested in implementing United States Patent Number 6,981,516 entitled "Fail save shut off valve for filtering systems employing candle filters." Disclosed in this patent is a novel fail save shut off valve system that allows fluid flow during normal operational conditions, but prevents the flow of fluids in the event of system failure upstream that causes over- pressurization. It is particularly well suited for use in conjunction with hot gas filtering systems, which utilize ceramic candle filters. Used in such a hot gas system, the fail save valve stops the flow

234

Publications  

NLE Websites -- All DOE Office Websites (Extended Search)

Wang Lan Clear All Filters 2011 Price, Lynn K., Ali Hasanbeigi, Nan Zhou, Arvind Thekdi, and Wang Lan. Increasing Energy Efficiency and Reducing Emissions from China's Cement...

235

Active imaging system with Faraday filter  

DOE Patents (OSTI)

This invention is comprised of an active imaging system which has a low to medium powered laser transmitter and a receiver wherein the receiver includes a Faraday filter with an ultranarrow optical bandpass and a bare (nonintensified) CCD camera. The laser is locked in the vicinity of the passband of the Faraday filter. The system has high sensitivity to the laser illumination wile eliminating solar background.

Snyder, J.J.

1992-12-31T23:59:59.000Z

236

Electrical diesel particulate filter (DPF) regeneration  

SciTech Connect

An exhaust system that processes exhaust generated by an engine includes a diesel particulate filter (DPF) that is disposed downstream of the engine and that filters particulates from the exhaust. An electrical heater is disposed upstream of the DPF and selectively heats the exhaust to initiate combustion of the particulates within the exhaust as it passes therethrough. Heat generated by combustion of the particulates induces combustion of particulates within the DPF.

Gonze, Eugene V; Ament, Frank

2013-12-31T23:59:59.000Z

237

Pulse-Jet Fabric Filter Guidelines  

Science Conference Proceedings (OSTI)

Power plants need to reduce stack emissions of mercury, filterable particulate matter (FPM), and acid gases to comply with the Mercury and Air Toxics Standards (MATS) issued by the U.S. Environmental Protection Agency (EPA) on February 16, 2012. The MATS standard requires that total stack FPM be maintained at < 0.03 lb/MMBtu. As particulate emission regulations become more stringent, the use of baghouses (also known as fabric filters) for particulate control on coal-fired boilers in the ...

2012-12-13T23:59:59.000Z

238

In-place HEPA filter penetration test  

SciTech Connect

We have demonstrated the feasibility of conducting penetration tests on high efficiency particulate air (HEPA) filters as installed in nuclear ventilation systems. The in-place penetration test, which is designed to yield equivalent penetration measurements as the standard DOP efficiency test, is based on measuring the aerosol penetration of the filter installation as a function of particle size using a portable laser particle counter. This in-place penetration test is compared to the current in-place leak test using light scattering photometers for single HEPA filter installations and for HEPA filter plenums using the shroud method. Test results show the in-place penetration test is more sensitive than the in-place leak test, has a similar operating procedure, but takes longer to conduct. Additional tests are required to confirm that the in-place penetration test yields identical results as the standard dioctyl phthalate (DOP) penetration test for HEPA filters with controlled leaks in the filter and gasket and duct by-pass leaks. Further development of the procedure is also required to reduce the test time before the in- place penetration test is practical.

Bergman, W.; Wilson, kK.; Elliott, J.; Bettencourt, B.; Slawski, J.W.

1997-01-01T23:59:59.000Z

239

Submitted to: Submitted by:  

E-Print Network (OSTI)

In preparing this report, we received support and assistance from many individuals. We would first like to thank the individuals involved with collecting and processing the survey data on which this report is based: Martha Kovac, who directed the survey, her assistant Betsy Santos, and the many other staff who assisted in developing the survey instrument and conducting the survey interviews; John Hall, who led the sampling and weight development, and his assistant Yuhong Zheng. We also thank several individuals at the Santa Clara Family Health Plan (SCFHP) for their ongoing and thoughtful assistance with the data collection process: John Pawlyshyn and Karen Gregory, who provided the administrative data files on which the survey sample is based and offered ongoing consultation on these files; Mayra Koenig, who, along with her phone center staff, conducted initial calls to families selected for the survey; and Janie Tyre and Pat Posey, who provided information on a range of issues related to the Healthy Kids program and our data collection efforts. We also thank outreach staff at the SCFHP, the Health Trust and the Santa Clara Valley Health and Hospital System (SCVHHS), along with staff at the Services, Immigration Rights, and Education Network (SIREN) in Santa Clara County, for providing information about the study to the community. Finally, we thank the pair of skilled programmers who assisted us with the analysis of the survey and administrative data files:

Christopher Trenholm; Embry M. Howell; Dana Hughes; Sean Orzol; The David; Lucile Packard Foundation; Christopher Trenholm Acknowledgments

2005-01-01T23:59:59.000Z

240

Organization Name Date Submitted File Name ACEEE Steve Nadel  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Submitted File Name ACEEE Steve Nadel 4/15/2011 ACEEE 4.15.2011 Alameda-Contra Coasta Transit District Chris Peeples 4/15/2011 Alameda-Contra Coasta Transit District 4.15.2011 American Academy of Arts and Sciences Robert W. Fri and Leslie C. Berlowitz 4/15/2011 American Academy of Arts and Science 4.15.2011 American Electric Power Michael L. Weinstein 4/15/2011 AEP 4.15.2011 American Gas Association, American Gas Foundation, American Public Gas Association, American Public Gas Association Research Foundation, Interstate Natural Gas Association of America, and the INGAA Foundation, Inc. Andrew K. Soto 4/15/2011 American Gas Association 4.15.2011 American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc. Mark Ames 4/14/2011 American Society of Heating, Refrigerating and Air-Conditioning

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Cermet Filters To Reduce Diesel Engine Emissions  

DOE Green Energy (OSTI)

Pollution from diesel engines is a significant part of our nation's air-quality problem. Even under the more stringent standards for heavy-duty engines set to take effect in 2004, these engines will continue to emit large amounts of nitrogen oxides and particulate matter, both of which affect public health. To address this problem, the Idaho National Engineering and Environmental Laboratory (INEEL) invented a self-cleaning, high temperature, cermet filter that reduces heavy-duty diesel engine emissions. The main advantage of the INEEL cermet filter, compared to current technology, is its ability to destroy carbon particles and NOx in diesel engine exhaust. As a result, this technology is expected to improve our nation's environmental quality by meeting the need for heavy-duty diesel engine emissions control. This paper describes the cermet filter technology and the initial research and development effort.Diesel engines currently emit soot and NOx that pollute our air. It is expected that the U.S. Environmental Protection Agency (EPA) will begin tightening the regulatory requirements to control these emissions. The INEEL's self-cleaning, high temperature cermet filter provides a technology to clean heavy-duty diesel engine emissions. Under high engine exhaust temperatures, the cermet filter simultaneously removes carbon particles and NOx from the exhaust gas. The cermet filter is made from inexpensive starting materials, via net shape bulk forming and a single-step combustion synthesis process, and can be brazed to existing structures. It is self-cleaning, lightweight, mechanically strong, thermal shock resistant, and has a high melting temperature, high heat capacity, and controllable thermal expansion coefficient. The filter's porosity is controlled to provide high removal efficiency for carbon particulate. It can be made catalytic to oxidize CO, H2, and hydrocarbons, and reduce NOx. When activated by engine exhaust, the filter produces NH3 and light hydrocarbon gases that can effectively destroy the NOx in the exhaust. The following sections describe cermet filter technology and properties of the INEEL filter.

Kong, Peter

2001-08-05T23:59:59.000Z

242

A noise rejection deadbeat control technique for active power filter  

Science Conference Proceedings (OSTI)

Compared with power filter, active power filter has a lot of advantages and it is an efficient technique to eliminate or limit the harmonic pollution in power system. However, the control of active power filter is very complex, and the control of current ... Keywords: active power filter, current control technique, deadbeat control, noise rejection, periodic noise, resetting integrator, sampling noise

Li-Dan Zhou; Mansoor Mansoor; Qian Ai; Da Xie; Chen Chen

2005-10-01T23:59:59.000Z

243

Electrically heated particulate matter filter with recessed inlet end plugs  

DOE Patents (OSTI)

A particulate matter (PM) filter includes filter walls having inlet ends and outlet ends. First adjacent pairs of the filter walls define inlet channels. Second adjacent pairs of the filter walls define outlet channels. Outlet end plugs are arranged in the inlet channels adjacent to the output ends. Inlet end plugs arranged in the outlet channels spaced from the inlet ends.

Gonze, Eugene V. (Pinckney, MI); Ament, Frank (Troy, MI)

2012-02-21T23:59:59.000Z

244

The State of the Art in Text Filtering  

Science Conference Proceedings (OSTI)

This paper develops a conceptual framework for text filtering practice and research, and reviews present practice in the field. Text filtering is an information seeking process in which documents are selected from a dynamic text stream to satisfy ... Keywords: Selective Dissemination of Information, collaborative, content-based, current awareness, information filtering, recommender systems., social filtering, text retrieval

Douglas W. Oard

1997-03-01T23:59:59.000Z

245

Proceedings: Indoor Air 2005 OZONE REMOVAL BY RESIDENTIAL HVAC FILTERS  

E-Print Network (OSTI)

Proceedings: Indoor Air 2005 2366 OZONE REMOVAL BY RESIDENTIAL HVAC FILTERS P Zhao1,2 , JA Siegel1, Austin, Texas 78758, USA ABSTRACT HVAC filters have a significant influence on indoor air quality% for Filter #2 at a face velocity of 0.81 cm/s. The potential for HVAC filters to affect ozone concentrations

Siegel, Jeffrey

246

Restoration of audio documents by means of extended Kalman filter  

Science Conference Proceedings (OSTI)

We present some results on audio restoration obtained with an algorithm that solves the problems of broadband noise filtering, signal parameters tracking, and impulsive noise removal by using the Extended Kalman Filter (EKF) theory. We show that, to ... Keywords: Kalman filtering, audio restoration, audio signal processing, extended Kalman filter (EKF), identification of time-varying autoregressive processes

Sergio Canazza; Giovanni De Poli; Gian Antonio Mian

2010-08-01T23:59:59.000Z

247

Method of and apparatus for testing the integrity of filters  

DOE Patents (OSTI)

A method of and apparatus are disclosed for testing the integrity of individual filters or filter stages of a multistage filtering system including a diffuser permanently mounted upstream and/or downstream of the filter stage to be tested for generating pressure differentials to create sufficient turbulence for uniformly dispersing trace agent particles within the airstream upstream and downstream of such filter stage. Samples of the particle concentration are taken upstream and downstream of the filter stage for comparison to determine the extent of particle leakage past the filter stage. 5 figs.

Herman, R.L.

1985-05-07T23:59:59.000Z

248

Method of and apparatus for testing the integrity of filters  

DOE Patents (OSTI)

A method of and apparatus for testing the integrity of individual filters or filter stages of a multistage filtering system including a diffuser permanently mounted upstream and/or downstream of the filter stage to be tested for generating pressure differentials to create sufficient turbulence for uniformly dispersing trace agent particles within the airstream upstream and downstream of such filter stage. Samples of the particle concentration are taken upstream and downstream of the filter stage for comparison to determine the extent of particle leakage past the filter stage.

Herman, Raymond L. (Richland, WA)

1985-01-01T23:59:59.000Z

249

Methods of and apparatus for testing the integrity of filters  

DOE Patents (OSTI)

A method of and apparatus for testing the integrity of individual filters or filter stages of a multistage filtering system including a diffuser permanently mounted upstream and/or downstream of the filter stage to be tested for generating pressure differentials to create sufficient turbulence for uniformly dispersing trace agent particles within the airstram upstream and downstream of such filter stage. Samples of the particel concentration are taken upstream and downstream of the filter stage for comparison to determine the extent of particle leakage past the filter stage.

Herman, R.L.

1984-01-01T23:59:59.000Z

250

A Simple Candle Filter Safeguard Device  

SciTech Connect

In order to reach the highest possible efficiencies in a coal-fired turbine-based power system, the turbine should be directly fired with the products of coal utilization. Two main designs employ these turbines: those based on pressurized fluidized-bed combustors (PFBCs) and those based on integrated gasification combined cycles (IGCCs). In both designs, the suspended particulates, or dust, must be cleaned from the gas before it enters the turbine to prevent fouling and erosion of the blades. To produce the cleanest gas, barrier filters are being developed and are in commercial use. Barrier filters are composed of porous, high-temperature materials that allow the hot gas to pass but collect the dust on the surface. The three main configurations are candle, cross-flow, and tube. Both candle and tube filters have been tested extensively. They are primarily composed of coarsely porous ceramic that serves as a structural support, overlain with a thin, microporous ceramic layer o n the dirty gas side that serves as the primary filter surface. They are highly efficient at removing particulate matter from the gas stream and, because of their ceramic construction, are resistant to gas and ash corrosion. However, ceramics are brittle, and individual elements can fail, allowing the particulates to pass through the hole left by the filter element and erode the turbine. Because of the possibility of occasional filter breakage, safeguard devices (SGDs) must be employed to prevent the dust streaming through broken filters from reaching the turbine. The Energy & Environmental Research Center (EERC) safeguard device is composed of three main parts: the ceramic substrate, the adhesive coating, and the safeguard device housing. This report describes the development and laboratory testing of each of those parts as well as the bench-scale performance of both types of complete SGDs.

Hurley, J.P.; Henderson, A.K.; Swanson, M.L.

2002-09-18T23:59:59.000Z

251

Advances in Filter Miniaturization and Design/Analysis of RF MEMS Tunable Filters  

E-Print Network (OSTI)

The main purpose of this dissertation was to address key issues in the design and analysis of RF/microwave filters for wireless applications. Since RF/microwave filters are one of the bulkiest parts of communication systems, their miniaturization is one of the most important technological challenges for the development of compact transceivers. In this work, novel miniaturization techniques were investigated for single-band, dual-band, ultra-wideband and tunable bandpass filters. In single-band filters, the use of cross-shaped fractals in half-mode substrate-integrated-waveguide bandpass filters resulted in a 37 percent size reduction. A compact bandpass filter that occupies an area of 0.315 mm2 is implemented in 90-nm CMOS technology for 20 GHz applications. For dual-band filters, using half-mode substrate-integrated-waveguides resulted in a filter that is six times smaller than its full-mode counterpart. For ultra-wideband filters, using slow-wave capacitively-loaded coplanar-waveguides resulted in a filter with improved stopband performance and frequency notch, while being 25 percent smaller in size. A major part of this work also dealt with the concept of 'hybrid' RF MEMS tunable filters where packaged, off-the-shelf RF MEMS switches were used to implement high-performance tunable filters using substrate-integrated-waveguide technology. These 'hybrid' filters are very easily fabricated compared to current state-of-the-art RF MEMS tunable filters because they do not require a clean-room facility. Both the full-mode and half-mode substrate-integrated waveguide tunable filters reported in this work have the best Q-factors (93 - 132 and 75 - 140, respectively) compared to any 'hybrid' RF MEMS tunable filter reported in current literature. Also, the half-mode substrate-integrated waveguide tunable filter is 2.5 times smaller than its full-mode counterpart while having similar performance. This dissertation also presented detailed analytical and simulation-based studies of nonlinear noise phenomena induced by Brownian motion in all-pole RF MEMS tunable filters. Two independent mathematical methods are proposed to calculate phase noise in RF MEMS tunable filters: (1) pole-perturbation approach, and (2) admittance-approach. These methods are compared to each other and to harmonic balance noise simulations using the CAD-model of the RF MEMS switch. To account for the switch nonlinearity in the mathematical methods, a nonlinear nodal analysis technique for tunable filters is also presented. In summary, it is shown that output signal-to-noise ratio degradation due to Brownian motion is maximum for low fractional bandwidth, high order and high quality factor RF MEMS tunable filters. Finally, a self-sustained microwave platform to detect the dielectric constant of organic liquids is presented in this dissertation. The main idea is to use a voltage- controlled negative-resistance oscillator whose frequency of oscillation varies according to the organic liquid under test. To make the system self-sustained, the oscillator is embedded in a frequency synthesizer system, which is then digitally interfaced to a computer for calculation of dielectric constant. Such a system has potential uses in a variety of applications in medicine, agriculture and pharmaceuticals.

Sekar, Vikram

2011-08-01T23:59:59.000Z

252

Carbon fiber composite molecular sieve electrically regenerable air filter media  

DOE Patents (OSTI)

An electrically regenerable gas filter system includes a carbon fiber composite molecular sieve (CFCMS) filter medium. After a separate medium-efficiency pre-filter removes particulate from the supply airstream, the CFCMS filter sorbs gaseous air pollutants before the air is recirculated to the space. When saturated, the CFCMS media is regenerated utilizing a low-voltage current that is caused to pass through the filter medium.

Wilson, Kirk A. (Knoxville, TN); Burchell, Timothy D. (Oak Ridge, TN); Judkins, Roddie R. (Knoxville, TN)

1998-01-01T23:59:59.000Z

253

Hydrocarbon-enhanced particulate filter regeneration via microwave ignition  

DOE Patents (OSTI)

A regeneration method for a particulate filter includes estimating a quantity of particulate matter trapped within the particulate filter, comparing the quantity of particulate matter to a predetermined quantity, heating at least a portion of the particulate filter to a combustion temperature of the particulate matter, and introducing hydrocarbon fuel to the particulate filter. The hydrocarbon fuel facilitates combustion of the particulate matter to regenerate the particulate filter.

Gonze, Eugene V. (Pinckney, MI); Brown, David B. (Brighton, MI)

2010-02-02T23:59:59.000Z

254

Removable, hermetically-sealing, filter attachment system for hostile environments  

DOE Patents (OSTI)

A removable and reusable filter attachment system. A filter medium is fixed o, and surrounded by, a filter frame having a coaxial, longitudinally extending, annular rim. The rim engages an annular groove which surrounds the opening of a filter housing. The annular groove contains a fusible material and a heating mechanism for melting the fusible material. Upon resolidifying, the fusible material forms a hermetic bond with the rim and groove. Remelting allows detachment and replacement of the filter frame.

Mayfield, Glenn L. (Richland, WA)

1983-01-01T23:59:59.000Z

255

A Statistical Investigation of the Sensitivity of Ensemble-Based Kalman Filters to Covariance Filtering  

Science Conference Proceedings (OSTI)

This paper investigates the effects of spatial filtering on the ensemble-based estimate of the background error covariance matrix in an ensemble-based Kalman filter (EnKF). In particular, a novel kernel smoothing method with variable bandwidth is ...

Mikyoung Jun; Istvan Szunyogh; Marc G. Genton; Fuqing Zhang; Craig H. Bishop

2011-09-01T23:59:59.000Z

256

Performance Analysis of DS Signal Code Acquisition Using the Matched Filter and the Median Filter  

Science Conference Proceedings (OSTI)

The theoretical analysis and simulation of the performance of a matched filter code acquisition structure with a median filter as the aiding device to cancel CW jamming in the AWGN channel is described. Both coherent and noncoherent structures are ... Keywords: interference cancellation, synchronization

J. Iinatti; P. Leppnen

1998-09-01T23:59:59.000Z

257

Submit Your Home Energy Efficiency Questions Now for Earth Day Google+  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Submit Your Home Energy Efficiency Questions Now for Earth Day Submit Your Home Energy Efficiency Questions Now for Earth Day Google+ Hangout Submit Your Home Energy Efficiency Questions Now for Earth Day Google+ Hangout April 2, 2013 - 10:40am Addthis Submit a video question now for our Earth Day Google+ Hangout on home energy efficiency. | Graphic courtesy of Sarah Gerrity, Energy Department. Submit a video question now for our Earth Day Google+ Hangout on home energy efficiency. | Graphic courtesy of Sarah Gerrity, Energy Department. Rebecca Matulka Rebecca Matulka Digital Communications Specialist, Office of Public Affairs How can I participate? Submit a video question in advance. All you need to do is create a 30-second video, upload it to YouTube before April 16 and tag it with #askEnergy. Email your questions to newmedia@hq.doe.gov.

258

Development of Self-destructing Filter Cake  

E-Print Network (OSTI)

The main goal of drilling a horizontal well is to enhance productivity or injectory by placing a long distance drain-hole within the pay-zone. Poor drilling fluid design results in difficulties such as poor hole cleaning, excessive torque or drag, wellbore instability, stuck drill string, loss of circulation, subsurface pressure control, poor cement jobs, and difficulties associated with running electric logs and formation damage can result. Neither of the conventional chemical cleaning methods can overcome problems for filter-cake removal in long horizontal and maximum reservoir contact wells because of limitations such as the complex geometry of wells, non-uniform chemical distribution, low contact between cleaning fluids/filter cake, and high chemical reaction rate, especially at high temperatures. This study describes a novel self-destructing drilling fluid system. Filter cakes are formed from a formula of drilling fluid that have a mixture of solid acid precursor and particulate solid acid-reactive materials. Then in the presence of water, the solid acid precursor (polylactic acid) hydrolyzes and dissolves, generating acids that then dissolve the solid acid-reactive materials (calcite). It effectively stimulates the horizontal section right after drilling and eliminates acidizing, resulting in significant cost savings, and improves filter-cake removal, thus enhancing the performance of the treated wells. A series of experiments have been run in the lab to determine the efficiency of this new system. Properties of this drilling fluid are measured. Experiments on solid acid particle size showed that the best size-distribution of solid acid precursor and solid reactive material to make a self-destructing filter cake is fine particles of calcium carbonate used as weighting material with 150 microns polylactic acid as solid acid precursor. By comparison of the results of the experiments at different temperatures, 230 degrees F has been chosen as the best temperature for running experiments. The self-destructing drilling fluid systems need enough time for the solid acid to be hydrolyzed and therefore remove the filter cake. After 20 hours of contact with the water as the only cleaning solution, about 80 percent of the filter cake was removed. Calcite is found to be the dominant compound in the sample of remained filter cake, which was proved by x-ray diffraction tests. Secondary electron microscopy (SEM) results show the morphology of the remained filter cake sample and confirm the crystalline area of calcite.

Rostami, Ameneh

2010-08-01T23:59:59.000Z

259

DEVELOPMENT OF METALLIC HOT GAS FILTERS  

SciTech Connect

Successful development of metallic filters with high temperature oxidation/corrosion resistance for fly ash capture is a key to enabling advanced coal combustion and power generation technologies. Compared to ceramic filters, metallic filters can offer increased resistance to impact and thermal fatigue, greatly improving filter reliability. A beneficial metallic filter structure, composed of a thin-wall (0.5mm) tube with uniform porosity (about 30%), is being developed using a unique spherical powder processing and partial sintering approach, combined with porous sheet rolling and resistance welding. Alloy choices based on modified superalloys, e.g., Ni-16Cr-4.5Al-3Fe (wt.%), are being tested in porous and bulk samples for oxide (typically alumina) scale stability in simulated oxidizing/sulfidizing atmospheres found in PFBC and IGCC systems at temperatures up to 850 C. Recent ''hanging o-ring'' exposure tests in actual combustion systems at a collaborating DOE site (EERC) have been initiated to study the combined corrosive effects from particulate deposits and hot exhaust gases. New studies are exploring the correlation between sintered microstructure, tensile strength, and permeability of porous sheet samples.

Anderson, I.E.; Gleeson, B.; Terpstra, R.L.

2003-04-23T23:59:59.000Z

260

Technical Basis for Averaging C-14 Filters, Interim Report: Carbon-14 Source Term Analysis for Encapsulated Filter Waste Forms  

Science Conference Proceedings (OSTI)

The number of power plants implementing submicron-size cartridge filters has increased with the incentive of radiation dose reduction. However, utilities are experiencing difficulty disposing of these filters due to significant increases in (14)C concentrations. This study provides an important technical basis for concentration averaging of encapsulated filters with the grouting of filter waste. The concentration averaging with grouting will save costs in disposal of Greater than Class C filters and will...

2000-11-07T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Hot gas filter and system assembly  

DOE Patents (OSTI)

A filter element for separating fine dirty particles from a hot gas. The filter element comprises a first porous wall and a second porous wall. Each porous wall has an outer surface and an inner surface. The first and second porous walls being coupled together thereby forming a substantially closed figure and open at one end. The open end is formed to be coupled to a hot gas clean up system support structure. The first and second porous walls define a channel beginning at the open end and terminate at the closed end through which a filtered clean gas can flow through and out into the clean gas side of a hot gas clean up system.

Lippert, Thomas Edwin (Murrysville, PA); Palmer, Kathryn Miles (Monroeville, PA); Bruck, Gerald Joseph (Murrysville, PA); Alvin, Mary Anne (Pittsburgh, PA); Smeltzer, Eugene E. (Export, PA); Bachovchin, Dennis Michael (Murrysville, PA)

1999-01-01T23:59:59.000Z

262

METAL MEDIA FILTERS, AG-1 SECTION FI  

Science Conference Proceedings (OSTI)

One application of metal media filters is in various nuclear air cleaning processes including applications for protecting workers, the public and the environment from hazardous and radioactive particles. To support this application the development of the ASME AG-1 FI Standard on Metal Media has been under way for more than ten years. Development of the proposed section has required resolving several difficult issues associated with operating conditions (media velocity, pressure drop, etc.), qualification testing, and quality acceptance testing. Performance characteristics of metal media are dramatically different than the glass fiber media with respect to parameters like differential pressures, operating temperatures, media strength, etc. These differences make existing data for a glass fiber media inadequate for qualifying a metal media filter for AG-1. In the past much work has been conducted on metal media filters at facilities such as Lawrence Livermore National Laboratory (LLNL) and Savannah River National Laboratory (SRNL) to qualify the media as High Efficiency Particulate Air (HEPA) Filters. Particle retention testing has been conducted at Oak Ridge Filter Test Facility and at Air Techniques International (ATI) to prove that the metal media meets or exceeds the 99.97% particle retention required for a HEPA Filter. Even with his testing, data was lacking to complete an AG-1 FI Standard on metal media. With funding secured by Mississippi State University (MSU) from National Nuclear Security Administration (NNSA), a research test stand is being designed and fabricated at MSU's Institute for Clean Energy Technology (ICET) Facility to obtain qualification data on metal media. This in turn will support required data needed for the FI Standard. The paper will discuss in detail how the test stand at MSU will obtain the necessary data to complete the FI Standard.

Adamson, D.

2012-05-23T23:59:59.000Z

263

Secondary Pollutants from Ozone Reaction with Ventilation Filters and Degradation of Filter Media Additives  

SciTech Connect

Prior research suggests that chemical processes taking place on the surface of particle filters employed in buildings may lead to the formation of harmful secondary byproducts. We investigated ozone reactions with fiberglass, polyester, cotton/polyester and polyolefin filter media, as well as hydrolysis of filter media additives. Studies were carried out on unused media, and on filters that were installed for 3 months in buildings at two different locations in the San Francisco Bay Area. Specimens from each filter media were exposed to {approx}150 ppbv ozone in a flow tube under a constant flow of dry or humidified air (50percent RH). Ozone breakthrough was recorded for each sample over periods of {approx}1000 min; the ozone uptake rate was calculated for an initial transient period and for steady-state conditions. While ozone uptake was observed in all cases, we did not observe significant differences in the uptake rate and capacity for the various types of filter media tested. Most experiments were performed at an airflow rate of 1.3 L/min (face velocity = 0.013 m/s), and a few tests were also run at higher rates (8 to 10 L/min). Formaldehyde and acetaldehyde, two oxidation byproducts, were quantified downstream of each sample. Those aldehydes (m/z 31 and 45) and other volatile byproducts (m/z 57, 59, 61 and 101) were also detected in real-time using Proton-Transfer Reaction - Mass Spectrometry (PTR-MS). Low-ppbv byproduct emissions were consistently higher under humidified air than under dry conditions, and were higher when the filters were loaded with particles, as compared with unused filters. No significant differences were observed when ozone reacted over various types of filter media. Fiberglass filters heavily coated with impaction oil (tackifier) showed higher formaldehyde emissions than other samples. Those emissions were particularly high in the case of used filters, and were observed even in the absence of ozone, suggesting that hydrolysis of additives, rather than ozonolysis, is the main formaldehyde source in those filters. Emission rates of formaldehyde and acetaldehyde were not found to be large enough to substantially increase indoor concentrations in typical building scenarios. Nevertheless, ozone reactions on HVAC filters cannot be ignored as a source of low levels of indoor irritants.

Destaillats, Hugo; Chen, Wenhao; Apte, Michael; Li, Nuan; Spears, Michael; Almosni, Jrmie; Brunner, Gregory; Zhang, Jianshun (Jensen); Fisk, William J.

2011-05-01T23:59:59.000Z

264

Electrically heated particulate filter using catalyst striping  

DOE Patents (OSTI)

An exhaust system that processes exhaust generated by an engine is provided. The system generally includes a particulate filter (PF) that filters particulates from the exhaust wherein an upstream end of the PF receives exhaust from the engine. A grid of electrically resistive material is applied to an exterior upstream surface of the PF and selectively heats exhaust passing through the grid to initiate combustion of particulates within the PF. A catalyst coating is applied to the PF that increases a temperature of the combustion of the particulates within the PF.

Gonze, Eugene V; Paratore, Jr., Michael J; Ament, Frank

2013-07-16T23:59:59.000Z

265

Electrically heated particulate filter enhanced ignition strategy  

DOE Patents (OSTI)

An exhaust system that processes exhaust generated by an engine is provided. The system generally includes a particulate filter (PF) that filters particulates from the exhaust wherein an upstream end of the PF receives exhaust from the engine. A grid of electrically resistive material is applied to an exterior upstream surface of the PF and selectively heats exhaust passing through the grid to initiate combustion of particulates within the PF. A catalyst coating applied to at least one of the PF and the grid. A control module estimates a temperature of the grid and controls the engine to produce a desired exhaust product to increase the temperature of the grid.

Gonze, Eugene V; Paratore, Jr., Michael J

2012-10-23T23:59:59.000Z

266

Electrically heated particulate filter with reduced stress  

DOE Patents (OSTI)

A system comprises a particulate matter (PM) filter comprising an inlet for receiving exhaust gas. A zoned heater is arranged in the inlet and comprises a resistive heater comprising N zones, where N is an integer greater than one. Each of the N zones comprises M sub-zones, where M is an integer greater than one. A control module selectively activates one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates others of the N zones.

Gonze, Eugene V.

2013-03-05T23:59:59.000Z

267

Parallel Implementation of an Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

Since mid-February 2013, the ensemble Kalman filter (EnKF) in operation at the Canadian Meteorological Centre uses a 600 300 global horizontal grid and 74 vertical levels. This yields more than 5 107 model coordinates. The EnKF has 192 members ...

P. L. Houtekamer; Bin He; Herschel L. Mitchell

268

Architectural implications of spatial thermal filtering  

Science Conference Proceedings (OSTI)

Process technology scaling, lagging supply voltage scaling, and the resulting exponential increase in power density, have made temperature a first-class design constraint in today's microprocessors. Prior work has shown that the silicon substrate acts ... Keywords: Aspect ratio, Granularity, Many-core, Spatial filtering, Temperature, Thermal management

Karthik Sankaranarayanan; Brett H. Meyer; Wei Huang; Robert Ribando; Hossein Haj-Hariri; Mircea R. Stan; Kevin Skadron

2013-01-01T23:59:59.000Z

269

Commercial Internet filters: Perils and opportunities  

Science Conference Proceedings (OSTI)

Organizations are becoming increasingly aware of Internet abuse in the workplace. Such abuse results in loss of workers' productivity, network congestion, security risks, and legal liabilities. To address this problem, organizations have started to adopt ... Keywords: Internet abuse, Internet filters, Text classification, Text mining

Chen-Huei Chou; Atish P. Sinha; Huimin Zhao

2010-03-01T23:59:59.000Z

270

Automatic image segmentation optimized by bilateral filtering  

Science Conference Proceedings (OSTI)

The object-based methodology is one of the most commonly used strategies for processing high spatial resolution images. A prerequisite to object-based image analysis is image segmentation, which is normally defined as the subdivision of an image into ... Keywords: bilateral filter, image segmentation, self-calibrating framework

Javier Sanchez; Estibaliz Martinez; Agueda Arquero; Diego Renza

2010-11-01T23:59:59.000Z

271

Filter type rotor for multistation photometer  

DOE Patents (OSTI)

A filter type rotor for a multistation photometer is provided. The rotor design combines the principle of cross-flow filtration with centrifugal sedimentation so that these occur simultaneously as a first stage of processing for suspension type fluids in an analytical type instrument. The rotor is particularly useful in whole-blood analysis.

Shumate, II, Starling E. (Knoxville, TN)

1977-07-12T23:59:59.000Z

272

Outbound SPIT filter with optimal performance guarantees  

Science Conference Proceedings (OSTI)

This paper presents a formal framework for identifying and filtering SPIT calls (SPam in Internet Telephony) in an outbound scenario with provable optimal performance. In so doing, our work is largely different from related previous work: our goal is ... Keywords: Internet telephony, SPAM, Security, Sequential probability ratio test

Tobias Jung, Sylvain Martin, Mohamed Nassar, Damien Ernst, Guy Leduc

2013-05-01T23:59:59.000Z

273

Preemptive Forecasts Using an Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

An ensemble Kalman filter (EnKF) estimates the error statistics of a model forecast using an ensemble of model forecasts. One use of an EnKF is data assimilation, resulting in the creation of an increment to the first-guess field at the ...

Brian J. Etherton

2007-10-01T23:59:59.000Z

274

Design of Sparse Filters for Channel Shortening  

Science Conference Proceedings (OSTI)

Channel shortening equalizers are used in acoustics to reduce reverberation, in error control decoding to reduce complexity, and in communication receivers to reduce inter-symbol interference. The cascade of a channel and channel shortening equalizer ... Keywords: Channel shortening, Discrete multi-tone modulation, Reverberant channels, Sparse filters, Time-domain equalizers

Aditya Chopra; Brian Lawrence Evans

2012-03-01T23:59:59.000Z

275

QUANTUM STOCHASTIC CALCULUS AND QUANTUM NONLINEAR FILTERING  

E-Print Network (OSTI)

QUANTUM STOCHASTIC CALCULUS AND QUANTUM NONLINEAR FILTERING V. P. BELAVKIN Abstract. A ?­algebraic inde...nite structure of quantum stochastic (QS) cal- culus is introduced and a continuity property...nitely dimensional nuclear space. The class of nondemolition output QS processes in quantum open systems

Belavkin, Viacheslav P.

276

Submitted to Solar Energy (Nov. 2011) Complete article Accepted version (v1, Jul. 2012)  

E-Print Network (OSTI)

Submitted to Solar Energy (Nov. 2011) Complete article Accepted version (v1, Jul. 2012) 1 THE SG2-00725987,version1-16Oct2012 Author manuscript, published in "Solar Energy 88, 10 (2012) Pages 3072-3083" DOI : 10.1016/j.solener.2012.07.018 #12;Submitted to Solar Energy (Nov. 2011) Complete article

277

How to Submit a Privacy Act Request | U.S. DOE Office of Science (SC)  

NLE Websites -- All DOE Office Websites (Extended Search)

How to Submit a Privacy Act Request How to Submit a Privacy Act Request Integrated Support Center (ISC) ISC Home About Services Freedom of Information Act (FOIA) Privacy Act Compilation of Systems of Records Energy Employees Occupational Illness Compensation Program Act (EEOICPA) How to Submit a Privacy Act Request Privacy Act Request Form .pdf file (99KB) Reference Links Categorical Exclusion Determinations Contact Information Integrated Support Center Roxanne Purucker U.S. Department of Energy 9800 S. Cass Avenue Argonne, IL 60439 P: (630) 252-2110 Larry Kelly U.S. Department of Energy 200 Administration Road Oak Ridge, TN 37830 P: (865) 576-0885 Privacy Act How to Submit a Privacy Act Request Print Text Size: A A A RSS Feeds FeedbackShare Page Related Links Privacy Act Request Form .pdf file (99KB) You may request your own Privacy Act records by submitting a request in

278

EIS-0396: Notice of Extension of Time to Submit Scoping Comments |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Extension of Time to Submit Scoping Comments Extension of Time to Submit Scoping Comments EIS-0396: Notice of Extension of Time to Submit Scoping Comments Global Nuclear Energy Partnership In response to public requests, the Department of Energy (DOE) announces an extension of time to submit comments on the proposed scope, alternatives, and environmental issues to be analyzed in the Programmatic Environmental Impact Statement for the Global Nuclear Energy Partnership (GNEP PEIS). Notice of Extension of Time to Submit Scoping Comments on the Programmatic Environmental Impact Statement for the Global Nuclear Energy Partnership, DOE/EIS-0396 (April 2007) 72 FR 15871 More Documents & Publications EIS-0359: DOE Notice of Availability of the Draft Supplement Analysis EIS-0360: DOE Notice of Availability of the Draft Supplement Analysis

279

Studying Altocumulus Plus Virga with Ground-based Active and Passive Remote Sensors Zhien Wang1, Kenneth Sassen2, David Whiteman3, and Belay Demoz3 1University of Maryland, Baltimore County, Catonsville, MD 21228 2University of Alaska, Fairbanks, Alaska 99775 3NASA Goddard Space Flight Center, Greenbelt, MD 20771 E-mail: zhien@agnes.gsfc.nasa.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Seasonal and Interannual Variations of Boundary-layer Mixed-phase Seasonal and Interannual Variations of Boundary-layer Mixed-phase Cloud Properties Observed at the ARCF NSA site Zhien Wang, Ming Zhao, and Min Deng University of Wyoming , Laramie, Wyoming, 82071, zwang@uwyo.edu References Curry, J. et al., 1996: Overview of Arctic cloud and radiation characteristics. J. Climate., 9, 1731-1764. Wang, Z. and K. Sassen, 2002: Cirrus cloud microphysical property retrieval using lidar and radar measurements, I: algorithm description and comparison with in situ data. J. Appl. Meteor., 41, 218-229. Wang, Z., K. Sassen, D. Whiteman, and B. Demoz, 2004: Studying altocumulus plus virga with ground-based active and passive remote sensors. J. Appl. Meteor.,43, 449-460. Wang, Z., 2007: Refined Two-channel Microwave Radiometer Liquid Water Path Retrieval at Cold Regions by Using Multiple-sensor Measurements. IEEE Geoscience and Remote

280

The RAW Filter: An Improvement to the RobertAsselin Filter in Semi-Implicit Integrations  

Science Conference Proceedings (OSTI)

Errors caused by discrete time stepping may be an important component of total model error in contemporary atmospheric and oceanic simulations. To reduce time-stepping errors in leapfrog integrations, the RobertAsselinWilliams (RAW) filter was ...

Paul D. Williams

2011-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Pulse-Jet Fabric Filter Guidelines: Volume 3, Utility Pulse-Jet Fabric Filters -- Case Studies  

Science Conference Proceedings (OSTI)

Power plants need to reduce stack emissions of mercury, filterable particulate matter (FPM), and acid gases to comply with the Mercury and Air Toxics Standards (MATS) issued by the U.S. Environmental Protection Agency (EPA) on February 16, 2012. The MATS standard requires that total stack FPM be maintained at < 0.03 lb/MMBtu. As particulate emission regulations become more stringent, the use of baghouses (also known as fabric filters) for particulate control on coal-fired boilers in the ...

2012-12-31T23:59:59.000Z

282

Laboratory measurement of secondary pollutant yields from ozone reaction with HVAC filters.  

E-Print Network (OSTI)

from Ozone Reaction with HVAC Filters Hugo Destaillats,from Ozone Reaction with HVAC Filters Hugo Destaillatsfrom Ozone Reaction with HVAC Filters Hugo Destaillats

Destaillats, Hugo

2012-01-01T23:59:59.000Z

283

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials  

E-Print Network (OSTI)

VOCs emitted by reactions of HVAC filters with ozone usingChemistry and Emissions on HVAC Filter Materials HugoChemistry and Emissions on HVAC Filter Materials Authors:

Destaillats, Hugo

2010-01-01T23:59:59.000Z

284

An Innovative Method for Dynamic Characterization of Fan Filter Unit Operation.  

E-Print Network (OSTI)

Filtration: Fan filter units. Final Report, LawrencePerformance of Fan Filter Units, Version 1.3. BerkeleyEfficient Fan filter units, Proceedings of Semiconductor

Xu, Tengfang

2006-01-01T23:59:59.000Z

285

Coupled-magnetic filters with adaptive inductance cancellation  

E-Print Network (OSTI)

Conventional filter circuits suffer from a number of limitations, including performance degradation due to capacitor parasitic inductance and the size and cost of magnetic elements. Coupled-magnetic filters have been ...

Lymar, Daria S

2005-01-01T23:59:59.000Z

286

Scalable Implementations of Ensemble Filter Algorithms for Data Assimilation  

Science Conference Proceedings (OSTI)

A variant of a least squares ensemble (Kalman) filter that is suitable for implementation on parallel architectures is presented. This parallel ensemble filter produces results that are identical to those from sequential algorithms already ...

Jeffrey L. Anderson; Nancy Collins

2007-08-01T23:59:59.000Z

287

A Non-Gaussian Ensemble Filter Update for Data Assimilation  

Science Conference Proceedings (OSTI)

A deterministic square root ensemble Kalman filter and a stochastic perturbed observation ensemble Kalman filter are used for data assimilation in both linear and nonlinear single variable dynamical systems. For the linear system, the ...

Jeffrey L. Anderson

2010-11-01T23:59:59.000Z

288

Parallel Implementation of a Kalman Filter for Constituent Data Assimilation  

Science Conference Proceedings (OSTI)

A Kalman filter for the assimilation of long-lived atmospheric chemical constituents was developed for two-dimensional transport models on isentropic surfaces over the globe. Since the Kalman filter calculates the error covariances of the ...

P. M. Lyster; S. E. Cohn; R. Mnard; L-P. Chang; S-J. Lin; R. G. Olsen

1997-07-01T23:59:59.000Z

289

Detection of Forced Climate Signals. Part 1: Filter Theory  

Science Conference Proceedings (OSTI)

This paper considers the construction of a linear smoothing filter for estimation of the forced part of a change in a climatological field such as the surface temperature. The filter is optimal in the sense that it suppresses the natural ...

Gerald R. North; Kwang-Y. Kim; Samuel S. P. Shen; James W. Hardin

1995-03-01T23:59:59.000Z

290

A Spatial Filter for Use in Finite Area Calculations  

Science Conference Proceedings (OSTI)

A multidimensional filter which selectively removes 2?x and 2?y noise is introduced. The filter is designed to be effective in finite area models with nonperiodic horizontal boundary conditions. An economical splitting technique, requiring an ...

William H. Raymond; Arthur Garder

1988-01-01T23:59:59.000Z

291

Integrated optical filters using Bragg gratings and resonators  

E-Print Network (OSTI)

This thesis provides an in-depth study of optical filters made using integrated Bragg gratings and Bragg resonators. Various topologies for making add/drop filters using integrated gratings are outlined. Each class of ...

Khan, Mohammad Jalal

2002-01-01T23:59:59.000Z

292

A New Method for Time Series Filtering near Endpoints  

Science Conference Proceedings (OSTI)

Time series filtering (e.g., smoothing) can be done in the spectral domain without loss of endpoints. However, filtering is commonly performed in the time domain using convolutions, resulting in lost points near the series endpoints. Multiple ...

Anthony Arguez; Peng Yu; James J. OBrien

2008-04-01T23:59:59.000Z

293

Practical gammatone-like filters for auditory processing  

Science Conference Proceedings (OSTI)

This paper deals with continuous-time filter transfer functions that resemble tuning curves at particular set of places on the basilar membrane of the biological cochlea and that are suitable for practical VLSI implementations. The resulting filters ...

2007-10-01T23:59:59.000Z

294

Extended versus Ensemble Kalman Filtering for Land Data Assimilation  

Science Conference Proceedings (OSTI)

The performance of the extended Kalman filter (EKF) and the ensemble Kalman filter (EnKF) are assessed for soil moisture estimation. In a twin experiment for the southeastern United States synthetic observations of near-surface soil moisture are ...

Rolf H. Reichle; Jeffrey P. Walker; Randal D. Koster; Paul R. Houser

2002-12-01T23:59:59.000Z

295

The discrete Kalman filtering approach for seismic signals deconvolution  

SciTech Connect

Seismic signals are a convolution of reflectivity and seismic wavelet. One of the most important stages in seismic data processing is deconvolution process; the process of deconvolution is inverse filters based on Wiener filter theory. This theory is limited by certain modelling assumptions, which may not always valid. The discrete form of the Kalman filter is then used to generate an estimate of the reflectivity function. The main advantage of Kalman filtering is capability of technique to handling continually time varying models and has high resolution capabilities. In this work, we use discrete Kalman filter that it was combined with primitive deconvolution. Filtering process works on reflectivity function, hence the work flow of filtering is started with primitive deconvolution using inverse of wavelet. The seismic signals then are obtained by convoluting of filtered reflectivity function with energy waveform which is referred to as the seismic wavelet. The higher frequency of wavelet gives smaller wave length, the graphs of these results are presented.

Kurniadi, Rizal; Nurhandoko, Bagus Endar B. [Departement of Physics Intitut Teknologi Bandung, Jl. Ganesha 10 Bandung (Indonesia)

2012-06-20T23:59:59.000Z

296

Preparation of Metal Filter Element for Fail Safety in IGCC Filter Unit  

SciTech Connect

Metal filter elements as the fail safety filter are fabricated by the methods using cold isostatic pressure (compress method) and binder (binder method) to form the filter element and tested in a experimental and bench units. The fail safety filter on the filtration system is mounted additionally in order to intercept the particle leak when the main filter element is broken. So it should have two contrary functions of a high permeability and being plugged easily. The filter element having high porosity and high plugging property was fabricated by the bind method. It has the porosity more than 50%, showed very small pressure drop less than 10mmH2O at the face velocity of 0.15m/s, and plugged within 5 minutes with the inhibition of the particle leak larger than 4 {micro}m. The test result of corrosion tendency in IGCC gas stream at 500 C shows SUS310L material is very reasonable among SUS310, SUS316, Inconel 600, and Hastelloy X.

Choi, J-H.; Ahn, I-S.; Bak, Y-C.; Bae, S-Y.; Ha, S-J.; Jang, H-J.

2002-09-18T23:59:59.000Z

297

Results from tests of DuPont crossflow filter  

SciTech Connect

Crossflow filtration will be used to filter radioactive waste slurry as part of the Late Wash Process.

Steimke, J.L.

2000-05-05T23:59:59.000Z

298

Independent component analysis based filtering for penumbral imaging  

Science Conference Proceedings (OSTI)

We propose a filtering based on independent component analysis (ICA) for Poisson noise reduction. In the proposed filtering, the image is first transformed to ICA domain and then the noise components are removed by a soft thresholding (shrinkage). The proposed filter, which is used as a preprocessing of the reconstruction, has been successfully applied to penumbral imaging. Both simulation results and experimental results show that the reconstructed image is dramatically improved in comparison to that without the noise-removing filters.

Chen Yenwei; Han Xianhua; Nozaki, Shinya [College of Information Science and Engineering, Ritsumeikan University, Shiga 525-8577 (Japan); Institute of Computational Science and Engineering, Ocean University of China, Shandong (China); Faculty of Engineering, University of the Ryukyus, Okinawa 903-0213 (Japan); Okinawa National College of Technology, Okinawa (Japan)

2004-10-01T23:59:59.000Z

299

Electrically heated particulate filter propagation support methods and systems  

Science Conference Proceedings (OSTI)

A control system that controls regeneration of a particulate filter is provided. The system generally includes a regeneration module that controls current to the particulate filter to initiate combustion of particulate matter in the particulate filter. A propagation module estimates a propagation status of the combustion of the particulate matter based on a combustion temperature. A temperature adjustment module controls the combustion temperature by selectively increasing a temperature of exhaust that passes through the particulate filter.

Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

2011-06-07T23:59:59.000Z

300

Microstrip filters for measurement and control of superconducting qubits  

E-Print Network (OSTI)

Careful filtering is necessary for observations of quantum phenomena in superconducting circuits at low temperatures. Measurements of coherence between quantum states requires extensive filtering to protect against noise coupled from room temperature electronics. We demonstrate distributed transmission line filters which cut off exponentially at GHz frequencies and can be anchored at the base temperature of a dilution refrigerator. The compact design makes them suitable to filter many different bias lines in the same setup, necessary for the control and measurement of superconducting qubits.

Longobardi, Luigi; Patel, Vijay; Chen, Wei; Lukens, James E

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

A mutual information extension to the matched filter  

Science Conference Proceedings (OSTI)

Matched filters are the optimal linear filters for signal detection under linear channel and white noise conditions. Their optimality is guaranteed in the additive white Gaussian noise channel due to the sufficiency of second-order statistics. In this ... Keywords: matched filter, mutual information, nonlinear distortion, signal detection

Deniz Erdogmus; Rati Agrawal; Jose C. Principe

2005-05-01T23:59:59.000Z

302

Kalman-type positioning filters with floor plan information  

Science Conference Proceedings (OSTI)

A family of Kalman-type filters that estimate the user's position indoors, using range measurements and floor plan data, is presented. The floor plan information is formulated as a set of linear constraints and is used to truncate the Gaussian posterior ... Keywords: Kalman filter, floor plan, inequality constraints, nonlinear filtering, positioning

Tommi Perl; Simo Ali-Lytty

2008-11-01T23:59:59.000Z

303

INEEL HEPA Filter Leach System: A Mixed Waste Solution  

SciTech Connect

Calciner operations and the fuel dissolution process at the Idaho National Engineering and Environmental Laboratory have generated many mixed waste high-efficiency particulate air (HEPA) filters. The HEPA Filter Leach System located at the Idaho Nuclear Technology and Engineering Center lowers radiation contamination levels and reduces cadmium, chromium, and mercury concentrations on spent HEPA filter media to below disposal limits set by the Resource Conservation and Recovery Act (RCRA). The treated HEPA filters are disposed as low-level radioactive waste. The technical basis for the existing system was established and optimized in initial studies using simulants in 1992. The treatment concept was validated for EPA approval in 1994 by leaching six New Waste Calcining Facility spent HEPA filters. Post-leach filter media sampling results for all six filters showed that both hazardous and radiological constituent levels were reduced so the filters could be disposed of as low-level radioactive waste. Since the validation tests the HEPA Filter Leach System has processed 78 filters in 1997 and 1998. The Idaho National Engineering and Environmental Laboratory HEPA Filter Leach System is the only mixed waste HEPA treatment system in the DOE complex. This process is of interest to many of the other DOE facilities and commercial companies that have generated mixed waste HEPA filters but currently do not have a treatment option available.

Argyle, Mark Don; Demmer, Ricky Lynn; Archibald, Kip Ernest; Brewer, Ken Neal; Pierson, Kenneth Alan; Shackelford, Kimberlee Rene; Kline, Kelli Suzanne

1999-03-01T23:59:59.000Z

304

INEEL HEPA Filter Leach System: A Mixed Waste Solution  

SciTech Connect

Calciner operations and the fuel dissolution process at the Idaho National Engineering and Environmental Laboratory have generated many mixed waste high-efficiency particulate air (HEPA)filters. The HEPA Filter Leach System located at the Idaho Nuclear Technology and Engineering Center lowers radiation contamination levels and reduces cadmium, chromium, and mercury concentrations on spent HEPA filter media to below disposal limits set by the Resource Conservation and Recovery Act (RCRA). The treated HEPA filters are disposed as low-level radioactive waste. The technical basis for the existing system was established and optimized in initial studies using simulants in 1992. The treatment concept was validated for EPA approval in 1994 by leaching six New Waste Calcining Facility spent HEPA filters. Post-leach filter media sampling results for all six filters showed that both hazardous and radiological constituent levels were reduced so the filters could be disposed of as low-level radioactive waste. Since the validation tests the HEPA Filter Leach System has processed 78 filters in 1997 and 1998. The Idaho National Engineering and Environmental Laboratory HEPA Filter Leach System is the only mixed waste HEPA treatment system in the DOE complex. This process is of interest to many of the other DOE facilities and commercial companies that have generated mixed waste HEPA filters but currently do not have a treatment option available.

K. Archibald; K. Brewer; K. Kline; K. Pierson; K. Shackelford; M. Argyle; R. Demmer

1999-02-01T23:59:59.000Z

305

A unified method for optimizing linear image restoration filters  

Science Conference Proceedings (OSTI)

Image restoration from degraded images lies at the foundation of image processing, pattern recognition, and computer vision, so it has been extensively studied. A large number of image restoration filters have been devised so far. It is known that a ... Keywords: denoising, image restoration, linear filter, moving-average filter, subspace information criterion (SIC)

Masashi Sugiyama; Hidemitsu Ogawa

2002-11-01T23:59:59.000Z

306

An early decision algorithm to accelerate web content filtering  

Science Conference Proceedings (OSTI)

Real-time content analysis can be a bottleneck in Web filtering This work presents a simple, but effective early decision algorithm to accelerate the filtering process by examining only part of the Web content The algorithm can make the filtering decision, ...

Po-Ching Lin; Ming-Dao Liu; Ying-Dar Lin; Yuan-Cheng Lai

2006-01-01T23:59:59.000Z

307

Atmospheric Environment 41 (2007) 31513160 Ozone removal by HVAC filters  

E-Print Network (OSTI)

Atmospheric Environment 41 (2007) 3151­3160 Ozone removal by HVAC filters P. Zhao, J.A. Siegel?, R May 2006; accepted 14 June 2006 Abstract Residential and commercial HVAC filters that have been loaded of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial

Siegel, Jeffrey

308

Electrically heated particulate filter preparation methods and systems  

SciTech Connect

A control system that controls regeneration of a particulate filter is provided. The system generally includes a fuel control module that controls injection of fuel into exhaust that passes through the particulate filter. A regeneration module controls current to the particulate filter to initiate regeneration after the fuel has been injected into the exhaust.

Gonze, Eugene V [Pinckney, MI

2012-01-31T23:59:59.000Z

309

Reduced-rank adaptive filtering using Krylov subspace  

Science Conference Proceedings (OSTI)

A unified view of several recently introduced reduced-rank adaptive filters is presented. As all considered methods use Krylov subspace for rank reduction, the approach taken in this work is inspired from Krylov subspace methods for iterative solutions ... Keywords: Krylov subspace methods, adaptive filters, array processing, multiuser detection, reduced-rank adaptive filters

Sergue Burykh; Karim Abed-Meraim

2002-01-01T23:59:59.000Z

310

Adaptive filtering with bandwidth constraints in the feedback path  

Science Conference Proceedings (OSTI)

This paper introduces a new, adaptive-filter-based controller that shows advantageous properties from the viewpoint of its communication requirement. The algorithm is called signed-error filtered-x LMS (SE-FxLMS). Its novelty is characterized by the ... Keywords: Adaptive filter based controller, FxLMS algorithm, Networked control systems, Signed-error algorithm, Wireless control

Gyrgy Orosz; Lszl Sujbert; Gbor Pceli

2012-01-01T23:59:59.000Z

311

Fracture behavior of advanced ceramic hot gas filters: Final report  

SciTech Connect

This report presents the results of mechanical/microstructural evaluation, thermal shock/fatigue testing, and stress analyses of advanced hot-gas filters obtained from different manufacturers. These filters were fabricated from both monolithic ceramics and composites. The composite filters, made of both oxide and nonoxide materials, were in both as-fabricated and exposed conditions, whereas the monolithic filters were made only of nonoxide materials. Mechanical property measurement of composite filters included diametral compression testing with O-ring specimens and burst-testing of short filter segments with rubber plugs. In-situ strength of fibers in the composite filters was evaluated by microscopic technique. Thermal shock/fatigue resistance was estimated by measuring the strengths of filter specimens before and after thermal cycling from an air environment at elevated temperatures to a room temperature oil bath. Filter performance during mechanical and thermal shock/fatigue loadings was correlated with microstructural observations. Micromechanical models were developed to derive properties of composite filter constituents on the basis of measured mechanical properties of the filters. Subsequently, these properties were used to analytically predict the performance of composite filters during thermal shock loading.

Singh, J.P.; Majumdar, S.; Sutaria, M.; Bielke, W. [Argonne National Lab., IL (United States). Energy Technology Div.

1997-03-01T23:59:59.000Z

312

Optimizing performance of ceramic pot filters in Northern Ghana and modeling flow through paraboloid-shaped filters/  

E-Print Network (OSTI)

This work aimed to inform the design of ceramic pot filters to be manufactured by the organization Pure Home Water (PHW) in Northern Ghana, and to model the flow through an innovative paraboloid-shaped ceramic pot filter. ...

Miller, Travis Reed

2010-01-01T23:59:59.000Z

313

Oil Bypass filter technology evaluation final report  

NLE Websites -- All DOE Office Websites (Extended Search)

6-01355 6-01355 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Final Report TECHNICAL REPORT Larry Zirker James Francfort Jordan Fielding March 2006 Idaho National Laboratory Operated by Battelle Energy Alliance INL/EXT-06-01355 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Final Report Larry Zirker James Francfort Jordan Fielding March 2006 Idaho National Laboratory Transportation Technology Department Idaho Falls, Idaho 83415 Prepared for the U.S. Department of Energy Assistant Secretary for Energy Efficiency and Renewable Energy Under DOE Idaho Operations Office Contract DE-AC07-05ID14517

314

Fast adaptive elliptical filtering using box splines  

E-Print Network (OSTI)

We demonstrate that it is possible to filter an image with an elliptic window of varying size, elongation and orientation with a fixed computational cost per pixel. Our method involves the application of a suitable global pre-integrator followed by a pointwise-adaptive localization mesh. We present the basic theory for the 1D case using a B-spline formalism and then appropriately extend it to 2D using radially-uniform box splines. The size and ellipticity of these radially-uniform box splines is adaptively controlled. Moreover, they converge to Gaussians as the order increases. Finally, we present a fast and practical directional filtering algorithm that has the capability of adapting to the local image features.

Chaudhury, Kunal Narayan; Unser, Michael

2009-01-01T23:59:59.000Z

315

Overlap zoned electrically heated particulate filter  

DOE Patents (OSTI)

A system includes a particulate matter (PM) filter that includes an upstream end for receiving exhaust gas and a downstream end. A zoned heater is arranged spaced from the upstream end and comprises N zones, where N is an integer greater than one, wherein each of the N zones comprises M sub-zones, where M is an integer greater than or equal to one, and wherein the N zones and the M sub-zones are arranged in P layers, where P is an integer greater than one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates non-selected ones of the N zones.

Gonze, Eugene V [Pinckney, MI; Chapman, Mark R [Brighton, MI

2011-07-19T23:59:59.000Z

316

Spam filtering using Kolmogorov complexity analysis  

Science Conference Proceedings (OSTI)

One of the most irrelevant side effects of e-commerce technology is the development of spamming as an e-marketing technique. Spam e-mails (or unsolicited commercial e-mails) induce a burden for everybody having an electronic mailbox: detecting and ... Keywords: Kolmogorov complexity, anti-spam techniques, clustering, compression, e-marketing, information content, k-nearest neighbours, spam filtering, spamming, unsolicited e-mails

G. Richard; A. Doncescu

2008-05-01T23:59:59.000Z

317

Alpha migration through air filters: A numerical simulation  

Science Conference Proceedings (OSTI)

This theoretical study investigates the migration of alpha-emitting particles through high-efficiency particulate air (HEPA) filters. As part of the study, a review of previous research relating to the alpha-migration phenomena was conducted. As a result of the literature review, a numerical model was developed to simulate the migration of alpha-emitting radionuclide aerosols through HEPA filters. This model predicts the filter performance with regard to particle penetration. It can be used to better estimate the penetration of alpha radioactive species through filter systems for environmental concerns, to aid in the use of current filter systems, and to design new filter systems. It is obvious from the review of the literature that evidence exists of migration of alpha radionuclide species through high-efficiency filter media. The theories suggest that nanometer-size particles can eventually penetrate fibrous filters because of gradual movement through the filter matrix. It is conjectured that this movement may be induced by energies caused by the alpha recoil from the decay process by thermal energies. It is further hypothesized that such nanometer-size particles, containing radionuclide species can be formed from larger particles already captured within the filter. The penetration of such small particles through high-efficiency filter media is so low that experimental corroboration of these mechanisms by penetration measurements is difficult at best. A number of items were identified that affect the migration of alpha-emitting particles through a filter. These include the size distribution of aerosol particles entering the filter, the size distribution of fragment particles produced by alpha recoil, the penetration of the challenge aerosols and fragment particles, the velocity through the filter, the radionuclide specific activity, the alpha recoil energy, and the surface-binding energies between the particle and the filter matrix.

Biermann, A.H.; da Roza, R.A.; Chang, Yun.

1991-12-11T23:59:59.000Z

318

Compact cyclone filter train for radiological and hazardous environments  

DOE Patents (OSTI)

A compact cyclone filter train is disclosed for the removal of hazardous and radiological particles from a gaseous fluid medium. This filter train permits a small cyclone separator to be used in a very small space envelope due to the arrangement of the filter housing adjacent to the separator with the cyclone separator and the filters mounted on a plate. The entire unit will have a hoist connection at the center of gravity so that the entire unit including the separator, the filters, and the base can be lifted and repositioned as desired. 3 figs.

Bench, T.R.

1998-04-28T23:59:59.000Z

319

Preparing to Submit a License Application for Yucca Mountain  

Science Conference Proceedings (OSTI)

In 1982, the U.S. Congress passed the Nuclear Waste Policy Act, a Federal law that established U.S. policy for the permanent disposal of spent nuclear fuel and high-level radioactive waste. Congress amended the Act in 1987, directing the Department of Energy to study only Yucca Mountain, Nevada as the site for a permanent geologic repository. As the law mandated, the Department evaluated Yucca Mountain to determine its suitability as the site for a permanent geologic repository. Decades of scientific studies demonstrated that Yucca Mountain would protect workers, the public, and the environment during the time that a repository would be operating and for tens of thousands of years after closure of the repository. A repository at this remote site would also: preserve the quality of the environment; allow the environmental cleanup of Cold War weapons facilities; provide the nation with additional protection from acts of terrorism; and support a sound energy policy. Throughout the scientific evaluation of Yucca Mountain, there has been no evidence to disqualify Yucca Mountain as a suitable site for the permanent disposal of spent nuclear fuel and high-level radioactive waste. Upon completion of site characterization, the Secretary of Energy considered the results and concluded that a repository at Yucca Mountain would perform in a manner that protects public health and safety. The Secretary recommended the site to the President in February 2002; the President agreed and recommended to Congress that the site be approved. The Governor of Nevada submitted a notice of disapproval, and both houses of Congress acted to override the disapproval. In July 2002, the President's approval allowed the Department to begin the process of submittal of a license application for Yucca Mountain as the site for the nation's first repository for spent nuclear fuel and high-level radioactive waste. Yucca Mountain is located on federal land in Nye County in southern Nevada, an arid region of the United States, approximately 100 miles (160 kilometers) northwest of Las Vegas (Figure 1). The location is remote from population centers, and there are no permanent residents within approximately 14 miles (23 km) of the site. Overall, Nye County has a population density of about two persons per square mile (two persons per 2.5 square km); in the vicinity of Yucca Mountain, it is significantly less. Yucca Mountain is a series of north-south-trending ridges extending approximately 25 miles (40 km), and consists of successive layers of fine-grained volcanic tuffs, millions of years old, underlain by older carbonate rocks. The alternating layers of welded and nonwelded volcanic tuffs have differing hydrologic properties that significantly impact the manner in which water moves through the mountain. The repository horizon will be in welded tuff located in the unsaturated zone, more than 1,000 feet (300 meters) above the water table in the present-day climate, and is expected to remain well above the water table during wetter future climate conditions. Future meteorology and climatology at Yucca Mountain are important elements in understanding the amount of water available to potentially interact with the waste.

W.J. Arthur; M.D. Voegele

2005-03-14T23:59:59.000Z

320

Guenter Tulip Filter Retrieval Experience: Predictors of Successful Retrieval  

Science Conference Proceedings (OSTI)

We report our experience with Guenter Tulip filter placement indications, retrievals, and procedural problems, with emphasis on alternative retrieval techniques. We have identified 92 consecutive patients in whom a Guenter Tulip filter was placed and filter removal attempted. We recorded patient demographic information, filter placement and retrieval indications, procedures, standard and nonstandard filter retrieval techniques, complications, and clinical outcomes. The mean time to retrieval for those who experienced filter strut penetration was statistically significant [F(1,90) = 8.55, p = 0.004]. Filter strut(s) IVC penetration and successful retrieval were found to be statistically significant (p = 0.043). The filter hook-IVC relationship correlated with successful retrieval. A modified guidewire loop technique was applied in 8 of 10 cases where the hook appeared to penetrate the IVC wall and could not be engaged with a loop snare catheter, providing additional technical success in 6 of 8 (75%). Therefore, the total filter retrieval success increased from 88 to 95%. In conclusion, the Guenter Tulip filter has high successful retrieval rates with low rates of complication. Additional maneuvers such as a guidewire loop method can be used to improve retrieval success rates when the filter hook is endothelialized.

Turba, Ulku Cenk, E-mail: uct5d@virginia.edu; Arslan, Bulent, E-mail: ba6e@virginia.edu; Meuse, Michael, E-mail: mm5tz@virginia.edu; Sabri, Saher, E-mail: ss2bp@virginia.ed [University of Virginia, Health System Foundation, Department of Radiology (United States); Macik, Barbara Gail, E-mail: bgm3s@virginia.ed [University of Virginia, Health System Foundation, Department of Internal Medicine/Hematology (United States); Hagspiel, Klaus D., E-mail: kdh2n@virginia.edu; Matsumoto, Alan H., E-mail: ahm4d@virginia.edu; Angle, John F., E-mail: jfa3h@virginia.ed [University of Virginia, Health System Foundation, Department of Radiology (United States)

2010-08-15T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Method of recovering hazardous waste from phenolic resin filters  

DOE Patents (OSTI)

A method has been found for treating phenolic resin filter, whereby the filter is solubilized within the filter cartridge housing so the filter material can be removed from the cartridge housing in a remote manner. The invention consists of contacting the filter within the housing with an aqueous solution of about 8 to 12M nitric acid, at a temperature from about 110 to 190{degree}F, maintaining the contact for a period of time sufficient to solubilize the phenolic material within the housing, and removing the solubilized phenolic material from the housing, thereby removing the filter cartridge from the housing. Any hazardous or other waste material can then be separated from the filter material by chemical or other means.

Meikrantz, D.H.; Bourne, G.L.; McFee, J.N.; Burdge, B.G.; McConnell, J.W. Jr.

1990-12-31T23:59:59.000Z

322

Kansas City Plant submits productivity savings under share-in-savings  

NLE Websites -- All DOE Office Websites (Extended Search)

Kansas City Plant submits productivity savings under share-in-savings Kansas City Plant submits productivity savings under share-in-savings program | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Kansas City Plant submits productivity savings under ... Kansas City Plant submits productivity savings under share-in-savings program Posted By Gayle Fisher

323

Department of Energy Submits $23.6 Billion Spending Plan to Congress for  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Department of Energy Submits $23.6 Billion Spending Plan to Department of Energy Submits $23.6 Billion Spending Plan to Congress for FY'07 Department of Energy Submits $23.6 Billion Spending Plan to Congress for FY'07 March 16, 2007 - 10:55am Addthis WASHINGTON, DC - U.S. Department of Energy (DOE) today submitted the Department's $23.598 billion spending plan to Congress for Fiscal Year (FY) 2007, a $45 million (0.2%) increase over the FY'07 request, as a result of the FY'07 Continuing Resolution. The spending plan will allow DOE to continue making marked progress in achieving President Bush's goal of bringing more clean energy sources to market to help cut dependence on fossil fuels, increasing our energy and economic security and boosting competitiveness. The Continuing Resolution, signed by President Bush on

324

Preparing and Submitting a Phase I Letter of Intent | U.S. DOE Office of  

Office of Science (SC) Website

and Submitting a Phase I Letter of Intent and Submitting a Phase I Letter of Intent Small Business Innovation Research (SBIR) and Small Business Technology Transfer (STTR) SBIR/STTR Home About Funding Opportunity Announcements (FOAs) Applicant and Awardee Resources Preparing and Submitting a Phase I Letter of Intent Preparing a DOE SBIR/STTR Phase I Grant Application Useful Documents for Awardees Commercialization Assistance Other Resources Awards SBIR/STTR Highlights Reporting Fraud Contact Information Small Business Innovation Research and Small Business Technology Transfer U.S. Department of Energy SC-29/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-5707 F: (301) 903-5488 E: sbir-sttr@science.doe.gov More Information » Applicant and Awardee Resources Preparing and Submitting a Phase I Letter of Intent

325

Submitting a Proposal to DOE | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Submitting a Proposal to DOE Submitting a Proposal to DOE Visiting Faculty Program (VFP) VFP Home Eligibility Benefits Participant Obligations How to Apply Selecting a Host DOE Laboratory Developing a Research Proposal Recommender Information Student Participants Submitting a Proposal to DOE Application Selection Process and Notification Key Dates Frequently Asked Questions Contact WDTS Home How to Apply Submitting a Proposal to DOE Print Text Size: A A A RSS Feeds FeedbackShare Page Through direct collaboration with research staff at DOE host laboratories, the VFP program provides an opportunity for faculty to help create innovative new capabilities and make discoveries germane to DOE science missions. Through the experience, visiting faculty members also develop integrated skills that translate to programs at their home institutions,

326

Attachment to Policy Flash on New Procedures for Submitting Clause or Template Changes  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

on New Procedures for Submitting Clause or Template on New Procedures for Submitting Clause or Template Changes The following are the new procedures for submitting requests to add new clauses or templates or to change existing clauses and templates (including local clauses and templates) in STRIPES: Note that we are not specifying a specific number of days for any step in the process until we have some statistics on how long this new process will take. ∗ Site Points of Contact (SPOCs) and Contract and Financial Assistance Policy Division (CFAPD) staff are the only individuals who can submit a request for a clause or template addition or revision to the STRIPES functional team. Requests from other than the SPOCs will not be reviewed. ∗ The new forms developed for the requests for clause and template additions or revisions

327

How to Submit a FOIA Request | U.S. DOE Office of Science (SC)  

NLE Websites -- All DOE Office Websites (Extended Search)

How to Submit a FOIA Request How to Submit a FOIA Request Integrated Support Center (ISC) ISC Home About Services Freedom of Information Act (FOIA) Privacy Act Advisory Exemptions How to Submit a FOIA Request FOIA Request Form Fee Waiver and Reduction Criteria Electronic Reading Room ISC Conventional Reading Rooms Reference Links Privacy Act Categorical Exclusion Determinations Contact Information Integrated Support Center Roxanne Purucker U.S. Department of Energy 9800 S. Cass Avenue Argonne, IL 60439 P: (630) 252-2110 Larry Kelly U.S. Department of Energy 200 Administration Road Oak Ridge, TN 37830 P: (865) 576-0885 Freedom of Information Act (FOIA) How to Submit a FOIA Request Print Text Size: A A A RSS Feeds FeedbackShare Page Related Links Electronic FOIA Request Form Office of Science Integrated Support Center (ISC)

328

Medical Information Technology trative skills of scheduling appointments, interacting with patients, submitting patient insurance claims using  

E-Print Network (OSTI)

Medical Information Technology - - trative skills of scheduling appointments, interacting with patients, submitting patient insurance claims using current coding procedures, and maintaining medical Description: Medical Information Technology Associate of Applied Science Medical Administrative Assisting

Crone, Elizabeth

329

Edge preserving orientation adaptive filtering P. Bakker, L.J. van Vliet, P.W. Verbeek  

E-Print Network (OSTI)

Edge preserving orientation adaptive filtering P. Bakker, L.J. van Vliet, P.W. Verbeek Pattern for combining orientation adaptive filtering and edge preserving filtering. The filter adapts to the local orientation and avoids filter- ing across borders. The local orientation for steering the filter

van Vliet, Lucas J.

330

Fail Save Shut Off Valve for Filtering Systems Employing Candle Filters  

DOE Patents (OSTI)

The invention relates to an apparatus that acts as a fail save shut off valve. More specifically, the invention relates to a fail save shut off valve that allows fluid flow during normal operational conditions, but prevents the flow of fluids in the event of system failure upstream that causes over-pressurization. The present invention is particularly well suited for use in conjunction with hot gas filtering systems, which utilize ceramic candle filters. Used in such a hot gas system the present invention stops the flow of hot gas and prevents any particulate laden gas from entering the clean side of the system.

VanOsdol, John

2006-01-03T23:59:59.000Z

331

N Reactor filter system fission-product retention assessment  

Science Conference Proceedings (OSTI)

Data for the N Reactor High-Efficiency Particulate Air (HEPA) filter and charcoal filter systems have been evaluated to determine appropriate filter efficiencies for elemental iodine, methyl iodide, hydrogen iodide, and particulates. The data supports the following filter efficiencies: particulates - 99.95%, elemental iodine - 99%, methyl iodide - 70%, and hydrogen iodide - 99%. The HEPA filter and charcoal filter system, loading capacities have been determined for both radionuclide and non-radioactive aerosols. The results demonstrated that the capacity of the N Reactor confinement filtration system is more than adequate to retain both radionuclide and non-radioactive aerosols postulated to be released during accident situations without overloading. In addition, potential filter failure due to unacceptable heat loads from collected radionuclides was evaluated. The results show that with an acceptable air flow through the filter system (greater than 850 ft/sup 3//min), the heat load on the filters from deposited radionuclides will not lead to filter failure. 30 refs., 8 figs., 13 tabs.

Muhlstein, L.D.; Jeppson, D.W.; McCormack, J.D.

1988-06-01T23:59:59.000Z

332

Advanced Techniques for Removal of Retrievable Inferior Vena Cava Filters  

Science Conference Proceedings (OSTI)

Inferior vena cava (IVC) filters have proven valuable for the prevention of primary or recurrent pulmonary embolism in selected patients with or at high risk for venous thromboembolic disease. Their use has become commonplace, and the numbers implanted increase annually. During the last 3 years, in the United States, the percentage of annually placed optional filters, i.e., filters than can remain as permanent filters or potentially be retrieved, has consistently exceeded that of permanent filters. In parallel, the complications of long- or short-term filtration have become increasingly evident to physicians, regulatory agencies, and the public. Most filter removals are uneventful, with a high degree of success. When routine filter-retrieval techniques prove unsuccessful, progressively more advanced tools and skill sets must be used to enhance filter-retrieval success. These techniques should be used with caution to avoid damage to the filter or cava during IVC retrieval. This review describes the complex techniques for filter retrieval, including use of additional snares, guidewires, angioplasty balloons, and mechanical and thermal approaches as well as illustrates their specific application.

Iliescu, Bogdan; Haskal, Ziv J., E-mail: ziv2@mac.com [University of Maryland School of Medicine, Division of Vascular and Interventional Radiology (United States)

2012-08-15T23:59:59.000Z

333

Qualifications of Candle Filters for Combined Cycle Combustion Applications  

Science Conference Proceedings (OSTI)

The direct firing of coal produces particulate matter that has to be removed for environmental and process reasons. In order to increase the current advanced coal combustion processes, under the U.S. Department of Energy's auspices, Siemens Westinghouse Power Corporation (SWPC) has developed ceramic candle filters that can operate at high temperatures. The Coal Research Center of Southern Illinois University (SIUC), in collaboration with SWPC, developed a program for long-term filter testing at the SIUC Steam Plant followed by experiments using a single-filter reactor unit. The objectives of this program funded by the U.S. Department of Energy were to identify and demonstrate the stability of porous candle filter elements for use in high temperature atmospheric fluidized-bed combustion (AFBC) process applications. These verifications were accomplished through extended time slipstream testing of a candle filter array under AFBC conditions using SIUC's existing AFBC boiler. Temperature, mass flow rate, and differential pressure across the filter array were monitored for a duration of 45 days. After test exposure at SIUC, the filter elements were characterized using Scanning Electron Microscopy and BET surface area analyses. In addition, a single-filter reactor was built and utilized to study long term filter operation, the permeability exhibited by a filter element before and after the slipstream test, and the thermal shock resilience of a used filter by observing differential pressure changes upon rapid heating and cooling of the filter. The data acquired during the slipstream test and the post-test evaluations demonstrated the suitability of filter elements in advanced power generation applications.

Tomasz Wiltowski

2008-08-31T23:59:59.000Z

334

Low pass filter for plasma discharge  

DOE Patents (OSTI)

An isolator is disposed between a plasma reactor and its electrical energy source in order to isolate the reactor from the electrical energy source. The isolator operates as a filter to attenuate the transmission of harmonics of a fundamental frequency of the electrical energy source generated by the reactor from interacting with the energy source. By preventing harmonic interaction with the energy source, plasma conditions can be readily reproduced independent of the electrical characteristics of the electrical energy source and/or its associated coupling network.

Miller, Paul A. (Albuquerque, NM)

1994-01-01T23:59:59.000Z

335

Hybrid quadrupole mass filter/quadrupole ion trap/time-of-flight-mass spectrometer for infrared multiple photon dissociation spectroscopy of mass-selected ions  

Science Conference Proceedings (OSTI)

We present a laboratory-constructed mass spectrometer optimized for recording infrared multiple photon dissociation (IRMPD) spectra of mass-selected ions using a benchtop tunable infrared optical parametric oscillator/amplifier (OPO/A). The instrument is equipped with two ionization sources, an electrospray ionization source, as well as an electron ionization source for troubleshooting. This hybrid mass spectrometer is composed of a quadrupole mass filter for mass selection, a reduced pressure ({approx}10{sup -5} Torr) quadrupole ion trap (QIT) for OPO irradiation, and a reflectron time-of-flight drift tube for detecting the remaining precursor and photofragment ions. A helium gas pulse is introduced into the QIT to temporarily increase the pressure and hence enhance the trapping efficiency of axially injected ions. After a brief pump-down delay, the compact ion cloud is subjected to the focused output from the continuous wave OPO. In a recent study, we implemented this setup in the study of protonated tryptophan, TrpH{sup +}, as well as collision-induced dissociation products of this protonated amino acid [W. K. Mino, Jr., K. Gulyuz, D. Wang, C. N. Stedwell, and N. C. Polfer, J. Phys. Chem. Lett. 2, 299 (2011)]. Here, we give a more detailed account on the figures of merit of such IRMPD experiments. The appreciable photodissociation yields in these measurements demonstrate that IRMPD spectroscopy of covalently bound ions can be routinely carried out using benchtop OPO setups.

Gulyuz, Kerim; Stedwell, Corey N.; Wang Da; Polfer, Nick C. [Department of Chemistry, University of Florida, P.O. Box 117200, Gainesville, Florida 32611 (United States)

2011-05-15T23:59:59.000Z

336

MMTF: THE MARYLAND-MAGELLAN TUNABLE FILTER  

Science Conference Proceedings (OSTI)

This paper describes the Maryland-Magellan Tunable Filter (MMTF) on the Magellan-Baade 6.5 m telescope. MMTF is based on a 150 mm clear aperture Fabry-Perot (FP) etalon that operates in low orders and provides transmission bandpass and central wavelength adjustable from {approx}5 A to {approx}15 A and from {approx}5000 A to over {approx}9200 A, respectively. It is installed in the Inamori Magellan Areal Camera and Spectrograph and delivers an image quality of {approx}0.''5 over a field of view of 27' in diameter (monochromatic over {approx}10'). This versatile and easy-to-operate instrument has been used over the past three years for a wide variety of projects. This paper first reviews the basic principles of FP tunable filters, and then provides a detailed description of the hardware and software associated with MMTF and the techniques developed to observe with this instrument and reduce the data. The main lessons learned in the course of the commissioning and implementation of MMTF are highlighted next, before concluding with a brief outlook on the future of MMTF and of similar facilities which are soon coming on line.

Veilleux, S.; Weiner, B. J.; Rupke, D. S. N. [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States)], E-mail: veilleux@astro.umd.edu, E-mail: bjw@as.arizona.edu, E-mail: drupke@ifa.hawaii.edu (and others)

2010-01-15T23:59:59.000Z

337

Filter system cost comparison for IGCC and PFBC power systems  

SciTech Connect

A cost comparison was conducted between the filter systems for two advanced coal-based power plants. The results from this study are presented. The filter system is based on a Westinghouse advanced particulate filter concept, which is designed to operate with ceramic candle filters. The Foster Wheeler second-generation 453 MWe (net) pressurized fluidized-bed combustor (PFBC) and the KRW 458 MWe (net) integrated gasification combined cycle (IGCC) power plants are used for the comparison. The comparison presents the general differences of the two power plants and the process-related filtration conditions for PFBC and IGCC systems. The results present the conceptual designs for the PFBC and IGCC filter systems as well as a cost summary comparison. The cost summary comparison includes the total plant cost, the fixed operating and maintenance cost, the variable operating and maintenance cost, and the effect on the cost of electricity (COE) for the two filter systems.

Dennis, R.A.; McDaniel, H.M.; Buchanan, T. [and others

1995-12-01T23:59:59.000Z

338

Method of producing monolithic ceramic cross-flow filter  

DOE Patents (OSTI)

Ceramic filter of various configuration have been used to filter particulates from hot gases exhausted from coal-fired systems. Prior ceramic cross-flow filters have been favored over other types, but those previously horn have been assemblies of parts somehow fastened together and consequently subject often to distortion or delamination on exposure hot gas in normal use. The present new monolithic, seamless, cross-flow ceramic filters, being of one-piece construction, are not prone to such failure. Further, these new products are made by novel casting process which involves the key steps of demolding the ceramic filter green body so that none of the fragile inner walls of the filter is cracked or broken.

Larsen, David A. (Clifton Park, NY); Bacchi, David P. (Schenectady, NY); Connors, Timothy F. (Watervliet, NY); Collins, III, Edwin L. (Albany, NY)

1998-01-01T23:59:59.000Z

339

Method of producing monolithic ceramic cross-flow filter  

DOE Patents (OSTI)

Ceramic filter of various configuration have been used to filter particulates from hot gases exhausted from coal-fired systems. Prior ceramic cross-flow filters have been favored over other types, but those previously have been assemblies of parts somehow fastened together and consequently subject often to distortion or delamination on exposure hot gas in normal use. The present new monolithic, seamless, cross-flow ceramic filters, being of one-piece construction, are not prone to such failure. Further, these new products are made by a novel casting process which involves the key steps of demolding the ceramic filter green body so that none of the fragile inner walls of the filter is cracked or broken. 2 figs.

Larsen, D.A.; Bacchi, D.P.; Connors, T.F.; Collins, E.L. III

1998-02-10T23:59:59.000Z

340

Printed Circuit Board Metal Powder Filters for Low Electron Temperatures  

E-Print Network (OSTI)

We report the characterisation of printed circuit boards (PCB) metal powder filters and their influence on the effective electron temperature which is as low as 22 mK for a quantum dot in a silicon MOSFET structure in a dilution refrigerator. We investigate the attenuation behaviour (10 MHz- 20 GHz) of filter made of four metal powders with a grain size below 50 um. The room-temperature attenuation of a stainless steel powder filter is more than 80 dB at frequencies above 1.5 GHz. In all metal powder filters the attenuation increases with temperature. Compared to classical powder filters, the design presented here is much less laborious to fabricate and specifically the copper powder PCB-filters deliver an equal or even better performance than their classical counterparts.

Filipp Mueller; Raymond N. Schouten; Matthias Brauns; Tian Gang; Wee Han Lim; Nai Shyan Lai; Andrew S. Dzurak; Wilfred G. van der Wiel; Floris A. Zwanenburg

2013-04-11T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Evaluation of a Cyclone and Hot Gas Filter System  

NLE Websites -- All DOE Office Websites (Extended Search)

a Cyclone and a Cyclone and Hot Gas Filter System Description The Wabash River Coal Gasification Plant uses an oxygen-blown E-Gas gasifier technology, owned by ConocoPhillips, which produces fuel gas containing significant amounts of fine particulates. Currently, particulates are cleaned from the fuel gas with metal candle filters. These filters require two costly plant shut-downs per year for cleaning or replacement. During the U.S Department of Energy-supported project

342

Investigation of Alternative Waste Forms for GTCC 14C Filters  

Science Conference Proceedings (OSTI)

This report demonstrates that both cement and vinyl ester-styrene (VES) are viable engineering solutions for the immobilization of Greater than Class C (GTCC) 14C filters. The number of power plants installing submicron-size cartridge filters has increased with the incentive of radiation dose reduction. However, utilities are experiencing difficulty disposing of these filters due to significant increases in 14C concentrations. By implementing the concentration averaging recommendations of this study, nuc...

2001-11-15T23:59:59.000Z

343

Advanced Vehicle Testing Activity: Oil Bypass Filter Testing...  

NLE Websites -- All DOE Office Websites (Extended Search)

Testing Reports to someone by E-mail Share Advanced Vehicle Testing Activity: Oil Bypass Filter Testing Reports on Facebook Tweet about Advanced Vehicle Testing Activity: Oil...

344

Ash reduction system using electrically heated particulate matter filter  

DOE Patents (OSTI)

A control system for reducing ash comprises a temperature estimator module that estimates a temperature of an electrically heated particulate matter (PM) filter. A temperature and position estimator module estimates a position and temperature of an oxidation wave within the electrically heated PM filter. An ash reduction control module adjusts at least one of exhaust flow, fuel and oxygen levels in the electrically heated PM filter to adjust a position of the oxidation wave within the electrically heated PM filter based on the oxidation wave temperature and position.

Gonze, Eugene V [Pinckney, MI; Paratore, Jr., Michael J; He, Yongsheng [Sterling Heights, MI

2011-08-16T23:59:59.000Z

345

Integrated filters for the on-chip silicon photonics platform.  

E-Print Network (OSTI)

??We investigate the properties of integrated dielectric filters for the purposes of on-chip routing of photons. We started with the use of high quality factor (more)

Frank, Ian Ward

2013-01-01T23:59:59.000Z

346

Oil Bypass Filter Technology Evaluation - Second Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-03-00620 U.S. Department of Energy FreedomCAR & Vehicle Technologies Oil Bypass Filter Technology Evaluation Second Quarterly Report January - March 2003 Larry Zirker...

347

Oil Bypass Filter Technology Evaluation - Fifth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-04-01618 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Fifth Quarterly Report October - December 2003...

348

Oil Bypass Filter Technology Evaluation - Eighth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-04-02486 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Eighth Quarterly Report July-September 2004...

349

Demonstrated Petroleum Reduction Using Oil Bypass Filter Technology...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy FreedomCAR & Vehicle Technologies Program Demonstrated Petroleum Reduction Using Oil Bypass Filter Technology on Heavy and Light Vehicles James Francfort (PI) Timothy...

350

Oil Bypass Filter Technology Performance Evaluation - First Quarterly...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-03-00129 U.S. Department of Energy FreedomCAR & Vehicle Technologies Oil Bypass Filter Technology Performance Evaluation First Quarterly Report Larry Zirker James...

351

Oil Bypass Filter Technology Evaluation - Sixth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-04-02004 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Sixth Quarterly Report January - March 2004...

352

Advanced Vehicle Testing Activity: Oil Bypass Filter Specifications...  

NLE Websites -- All DOE Office Websites (Extended Search)

and Test Procedures to someone by E-mail Share Advanced Vehicle Testing Activity: Oil Bypass Filter Specifications and Test Procedures on Facebook Tweet about Advanced...

353

Compact cyclone filter train for radiological and hazardous environments  

DOE Patents (OSTI)

A compact cyclone filter train for the removal of hazardous and radiologi particles from a gaseous fluid medium which permits a small cyclone separator to be used in a very small space envelope due to the arrangement of the filter housing adjacent to the separator with the cyclone separator and the filters mounted on a plate. The entire unit will have a hoist connection at the center of gravity so that the entire unit including the separator, the filters, and the base can be lifted and repositioned as desired.

Bench, Thomas R. (Pittsburgh, PA)

1998-01-01T23:59:59.000Z

354

Gates/filters in Flow Cytometry Data Visualization  

E-Print Network (OSTI)

The flowViz package provides tools for visualization of flow cytometry data. This document describes the support for visualizing gates (a.k.a. filters). 1

unknown authors

2010-01-01T23:59:59.000Z

355

Gates/filters in Flow Cytometry Data Visualization  

E-Print Network (OSTI)

The flowViz package provides tools for visualization of flow cytometry data. This document describes the support for visualizing gates (a.k.a. filters). 1

unknown authors

2012-01-01T23:59:59.000Z

356

A Training Program for Filter-Search Mine Detection Dogs  

E-Print Network (OSTI)

comparative Psychology A Training Program for Filter-Searchbehind and results of a training program designed to produceunderlying the training program were: (1) minimise

Fjellanger, R.; Andersen, E. K.; McLean, Ian. G.

2002-01-01T23:59:59.000Z

357

Cermet Materials, Self-Cleaning Cermet Filters, Apparatus and ...  

Another option permits an external heating element to be used to heat the cermet filter during use. ... Building Energy Efficiency; ... Solar Thermal; Startup America;

358

Evaluation of Alternative Filter Media for the Rotary Microfilter  

SciTech Connect

The Savannah River Site is currently developing and testing several processes to treat high level radioactive liquid waste. Each of these processes has a solid-liquid separation process that limits its throughput. Savannah River National Laboratory researchers identified and tested the rotary microfilter as a technology to increase solid-liquid separation throughput. The authors believe the rotary microfilter throughput can be improved by using a better filter membrane. Previous testing showed that asymmetric filters composed of a ceramic membrane on top of a stainless steel support produced higher filter flux than 100% stainless steel symmetric filters in crossflow filter tests. Savannah River National Laboratory and Oak Ridge National Laboratory are working together to develop asymmetric ceramic ? stainless steel composite filters and asymmetric 100% stainless steel filters to improve the throughput of the rotary microfilter. The Oak Ridge National Laboratory Inorganic Membrane Group fabricated samples of alternative filter membranes. In addition, Savannah River National Laboratory obtained samples of filter membranes from Pall, Porvair, and SpinTek. They tested these samples in a static test cell with feed slurries containing monosodium titanate and simulated sludge.

Poirier, M. R.; Herman, D. T.; Bhave, R.

2011-11-09T23:59:59.000Z

359

Parameters Impacting Crossflow Filter Performance of Hanford Tank ...  

Parameters Impacting Crossflow Filter Performance of Hanford Tank Waste Simulants Reid Peterson Justin Billings, Carolyn Burns, Richard Daniel, Phil Schonewill, Rick ...

360

Compact cyclone filter train for radiological and hazardous environments  

DOE Patents (OSTI)

A compact cyclone filter train is described for the removal of hazardous and radiological particles from a gaseous fluid medium which permits a small cyclone separator to be used in a very small space envelope due to the arrangement of the filter housing adjacent to the separator with the cyclone separators and the filters mounted on a plate. The entire unit will have a hoist connection at the center of gravity so that the entire unit including the separator, the filters, and the base can be lifted and repositioned as desired.

Bench, T.R.

1996-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Biodiesel Effects on Diesel Particle Filter Performance: Milestone Report  

DOE Green Energy (OSTI)

Research results on the performance of biodiesel and biodiesel blends with ultra-low sulfur diesel (ULSD) and a diesel particle filter (DPF).

Williams, A.; McCormick, R. L.; Hayes, R.; Ireland, J.

2006-03-01T23:59:59.000Z

362

Performance analysis of Non Linear Filtering Algorithms for underwater images  

E-Print Network (OSTI)

Image filtering algorithms are applied on images to remove the different types of noise that are either present in the image during capturing or injected in to the image during transmission. Underwater images when captured usually have Gaussian noise, speckle noise and salt and pepper noise. In this work, five different image filtering algorithms are compared for the three different noise types. The performances of the filters are compared using the Peak Signal to Noise Ratio (PSNR) and Mean Square Error (MSE). The modified spatial median filter gives desirable results in terms of the above two parameters for the three different noise. Forty underwater images are taken for study.

Padmavathi, Dr G; Kumar, Mr M Muthu; Thakur, Suresh Kumar

2009-01-01T23:59:59.000Z

363

Effect of Biodiesel Blends on Diesel Particulate Filter Performance  

DOE Green Energy (OSTI)

Presents results of tests of ultra-low sulfur diesel blended with soy-biodiesel at 5 percent using a Cummins ISB engine with a diesel particulate filter.

Williams, A.; McCormick, R. L.; Hayes, R. R.; Ireland, J.; Fang, H. L.

2006-11-01T23:59:59.000Z

364

Applications of moving granular-bed filters to advanced systems  

SciTech Connect

The contract is arranged as a base contract with three options. The objective of the base contract is to develop conceptual design(s) of moving granular bed filter and ceramic candle filter technology for control of particles from integrated gasification combined cycle (IGCC) systems, pressurized fluidized-bed combustors (PFBC), and direct coal fueled turbine (DCFT) environments. The conceptual design(s) of these filter technologies are compared, primarily from an economic perspective. The granular bed filter was developed through low pressure, high temperature (1600{degree}F) testing in the late 1970`s and early 1980`s. Collection efficiencies over 99% were obtained. In 1988, high pressure, high temperature testing was completed at New York University, Westbury, N.Y., utilizing a two advanced power generating plants were chosen for developing conceptual designs and cost estimates of the commercial sized filters. One is the 450 MWe, second generation pressurized fluidized bed combustion plant defined by Foster Wheeler. This plant originally included cross-flow filters for hot gas cleanup. The other plant under study is a 100 MWe, KRW air blown gasifier. A cross-flow filter was utilized for gas stream cleanup in this study also. Granular bed and ceramic candle filters were substituted for the cross-flow filters in both these plants, and the resulting costs were compared.

Wilson, K.W.; Haas, J.C.; Eshelman, M.B.

1993-09-01T23:59:59.000Z

365

DEVELOPMENT OF AN ADHESIVE CANDLE FILTER SAFEGUARD DEVICE  

SciTech Connect

In order to reach the highest possible efficiencies in a coal-fired turbine-based power system, the turbine should be directly fired with the products of coal conversion. Two main types of systems employ these turbines: those based on pressurized fluidized-bed combustors and those based on integrated gasification combined cycles. In both systems, suspended particulates must be cleaned from the gas stream before it enters the turbine so as to prevent fouling and erosion of the turbine blades. To produce the cleanest gas, barrier filters are being developed and are in use in several facilities. Barrier filters are composed of porous, high-temperature materials that allow the hot gas to pass but collect the particulates on the surface. The three main configurations of the barrier filters are candle, cross-flow, and tube filters. Both candle and tube filters have been tested extensively. They are composed of coarsely porous ceramic that serves as a structural support, overlain with a thin, microporous ceramic layer on the dirty gas side that serves as the primary filter surface. They are highly efficient at removing particulate matter from the gas stream and, because of their ceramic construction, are resistant to gas and ash corrosion. However, ceramics are brittle and individual elements can fail, allowing particulates to pass through the hole left by the filter element and erode the turbine. Preventing all failure of individual ceramic filter elements is not possible at the present state of development of the technology. Therefore, safeguard devices (SGDs) must be employed to prevent the particulates streaming through occasional broken filters from reaching the turbine. However, the SGD must allow for the free passage of gas when it is not activated. Upon breaking of a filter, the SGD must either mechanically close or quickly plug with filter dust to prevent additional dust from reaching the turbine. Production of a dependable rapidly closing autonomous mechanical device at high temperatures in a dusty gas stream is difficult because of problems with materials corrosion, dust leakage, and detection of filter failure. Therefore, the Energy & Environmental Research Center is using its knowledge of the factors that make filter dust sticky at gas filtration temperatures to make a simple and inexpensive SGD that employs an adhesive yet thermodynamically stable coating on a highly porous ceramic substrate. The SGDs are placed on top of individual candle filters at the filtered gas exit. Upon failure of the filter, the dirty gas flows through the SGD where the adhesive surface rapidly and permanently traps dust particles, causing the device to plug and prevent the dust from reaching the turbine.

John P. Hurley; Ann K. Henderson; Jan W. Nowok; Michael L. Swanson

2002-01-01T23:59:59.000Z

366

Integrated electric alternators/active filters  

E-Print Network (OSTI)

In response to energy crisis and power quality concerns, three different methodologies to integrate the concept of active filtering into the alternators are proposed. Wind energy, due to its free availability and its clean and renewable character, ranks as the most promising renewable energy resource that could play a key role in solving the worldwide energy crisis. An Integrated Doubly-fed Electric Alternator/Active filter (IDEA) for wind energy conversion systems is proposed. The proposed IDEA is capable of simultaneous capturing maximum power of wind energy and improving power quality, which are achieved by canceling the most significant and troublesome harmonics of the utility grid and power factor correction and reactive power compensation in the grid. The back-to-back current regulated power converters are employed to excite the rotor of IDEA. The control strategy of rotor-side power converter is based on position sensoreless field oriented control method with higher power density. Analysis and experimental results are presented to demonstrate the effectiveness of the proposed IDEA. In next step, an integrated synchronous machine/active filter is discussed. The proposed technology is essentially a rotating synchronous machine with suitable modification to its field excitation circuit to allow dc and ac excitations. It is shown that by controlling the ac excitation, the 5th and 7th harmonics currents of the utility are compensated. The proposed method is cost effective because it can be applied to existing standby generators in commercial and industrial plants with minimal modification to the excitation circuits. To boost the gain of harmonic compensatory, an advanced electric machine is proposed. An Asymmetric Airgap Concentrated Winding Synchronous Machine (AACWSM) with ac and dc excitation was designed and employed. It is shown that the AACWSM with its unique design, in addition to power generation capability, could be used to compensate the most dominant current harmonics of the utility. The proposed AACWSM can compensate for the 5th and 7th harmonics currents in the grid by controlling the ac field excitation. In addition, the 11th and 13th harmonics currents are also significantly reduced. This system can be used at medium and low voltages for generation or motoring mode of operation.

Abolhassani, Mehdi Towliat

2005-05-01T23:59:59.000Z

367

System Effects of High Efficiency Filters in Homes  

NLE Websites -- All DOE Office Websites (Extended Search)

System Effects of High Efficiency Filters in Homes System Effects of High Efficiency Filters in Homes Title System Effects of High Efficiency Filters in Homes Publication Type Conference Paper LBNL Report Number LBNL-6144E Year of Publication 2013 Authors Walker, Iain S., Darryl J. Dickerhoff, David Faulkner, and William J. N. Turner Conference Name ASHRAE Annual Conference Date Published 03/2013 Abstract Occupant concern about indoor air quality (IAQ) issues has led to the increased use of more effective air filters in residential heating and cooling systems. A drawback of improved filtration is that better filters tend to have more flow resistance. This can lead to lower system airflows that reduce heat exchanger efficiency, increase duct pressure that leads to increased air leakage for ducts and, in some case s, increased blower power consumption. There is currently little knowledge on the magnitude of these effects. In this study, the performance of ten central forced air systems was monitored for a year. The systems used either a Permanent Split Capacitor (PSC) or a Brushless Permanent Magnet (BPM) blower. Each system was operated with a range of filter efficiencies ranging from MERV 6 (the lowest currently permitted in ASHRAE Standard 62.2) up to MERV 16. Measurements were recorded every ten seconds for blower power, filter pressure drop, supply and return plenum pressures together with plenum and indoor temperatures. These detailed continuous measurements allowed observation of filter loading effects as well as the initial change in system performance when filters were swapped. The results of the field measurements were used in simulations to examine more general system performance effects for a wider range of climates. The field tests showed that system static pressures were highly influenced by filter selection, filter loading rates varied more from house to house than by MERV rating and overall were quite low in many of the homes. PSC motors showed reduced power and airflow as the filters loaded, but BPM motors attempted to maintain a constant airflow and increased their power to do so. The combined field test and simulation results from this study indicate that for MERV 10-13 filters the effects on energy use are small (5%) and usability. In systems using low MERV filters that are already close to blower performance limits the addition of a MERV 16 filter pushed the blowers to their performance limits.

368

Development of a Pulp Process Treating Contaminated HEPA Filters (III)  

SciTech Connect

The Pulp Process (PP) Treatment option was conceived as a replacement for the current Filter Leaching System (FLS). The FLS has operated at the Idaho Nuclear Technology and Engineering Center of the Idaho National Engineering and Environmental Laboratory since 1995 to treat radioactive, mixed waste HEPA filters. In recent years, the FLS has exhibited difficulty in removing mercury from the HEPA filters as the concentration of mercury in the spent HEPA filters has increased. The FLS leaches and washes the whole filter without any preparation or modification. The filter media and the trapped calcine particles are confined in a heavy filter housing that contributes to poor mixing zones around the edges of the filter, low media permeability, channeling of the liquid through cracks and tears in the filter media, and liquid retention between leach and rinse cycles. In the PP, the filter media and the trapped calcine particles are separated from the filter housing and treated as a pulp, taking advantage of improved contact with the leach solution that cannot be achieved when the media is still in the HEPA filter housing. In addition to removing the mercury more effectively, the PP generates less volume of liquid waste, requires a shorter leach cycle time, and possesses the versatility for treating filters of different sizes. A series of tests have been performed in the laboratory to demonstrate the advantages of the PP concept. These tests compare the PP with the FLS under controlled conditions that simulate the current operating parameters. A prior study using blended feed, a mixture of shredded clean HEPA filter media and non-radioactive calcine particles, indicated that the PP would significantly increases the calcine dissolution percentages. In this study, hazardous-metal contaminated HEPA filter media was studied. The results of side-by-side tests indicated that the PP increased the mercury removal percentage by 80% and might be a solution to the mercury removal problem encountered by the current FLS. A patent application has been filed for the PP and the patent is pending. In order to validate the PP and collect information for engineering design and economical feasibility studies, pilot plant scale tests are planned.

Hu, J. S.; Ramer, J.; Argyle, M. D.; Demmer, R. L.

2002-02-28T23:59:59.000Z

369

Venous Thromboembolism After Removal of Retrievable Inferior Vena Cava Filters  

SciTech Connect

The purpose of this study was to examine the incidence of new or recurrent venous thromboembolism (VTE) after retrieval of inferior vena cava (IVC) filters and risk factors associated with such recurrence. Between March 2001 and September 2008, at our institution, implanted retrievable vena cava filters were retrieved in 76 patients. The incidence of new or recurrent VTE after retrieval was reviewed and numerous variables were analyzed to assess risk factors for redevelopment of VTE after filter retrieval. In 5 (6.6%) of the 76 patients, redevelopment or worsening of VTE was seen after retrieval of the filter. Three patients (4.0%) had recurrent deep venous thrombosis (DVT) in the lower extremities and 2 (2.6%) had development of pulmonary embolism, resulting in death. Although there was no significant difference in the incidence of new or recurrent VTE related to any risk factor investigated, a tendency for development of VTE after filter retrieval was higher in patients in whom DVT in the lower extremities had been so severe during filter implantation that interventional radiological therapies in addition to traditional anticoagulation therapies were required (40% in patients with recurrent VTE vs. 23% in those without VTE; p = 0.5866 according to Fisher's exact probability test) and in patients in whom DVT remained at the time of filter retrieval (60% in patients with recurrent VTE vs. 37% in those without VTE; p = 0.3637). In conclusion, new or recurrent VTE was rare after retrieval of IVC filters but was most likely to occur in patients who had severe DVT during filter implantation and/or in patients with a DVT that remained at the time of filter retrieval. We must point out that the fatality rate from PE after filter removal was high (2.6%).

Yamagami, Takuji, E-mail: yamagami@koto.kpu-m.ac.jp; Tanaka, Osamu; Yoshimatsu, Rika; Miura, Hiroshi; Nishimura, Tsunehiko [Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Department of Radiology (Japan)

2010-02-15T23:59:59.000Z

370

Electromagnetic interference filter for automotive electrical systems  

DOE Patents (OSTI)

A filter for an automotive electrical system includes a substrate having first and second conductive members. First and second input terminals are mounted to the substrate. The first input terminal is electrically connected to the first conductive member, and the second input terminal is electrically connected to the second conductive member. A plurality of capacitors are mounted to the substrate. Each of the capacitors is electrically connected to at least one of the first and second conductive members. First and second power connectors are mounted to the substrate. The first power connector is electrically connected to the first conductive member, and the second power connector is electrically connected to the second conductive member. A common mode choke is coupled to the substrate and arranged such that the common mode choke extends around at least a portion of the substrate and the first and second conductive members.

Herron, Nicholas Hayden; Carlson, Douglas S; Tang, David; Korich, Mark D

2013-07-02T23:59:59.000Z

371

Tunable high-q superconducting notch filter  

DOE Patents (OSTI)

A superconducting notch filter is made of three substrates disposed in a cryogenic environment. A superconducting material is disposed on one substrate in a pattern of a circle and an annular ring connected together. The second substrate has a corresponding pattern to form a parallel plate capacitor and the second substrate has the circle and annular ring connected by a superconducting spiral that forms an inductor. The third substrate has a superconducting spiral that is placed parallel to the first superconducting spiral to form a transformer. Relative motion of the first substrate with respect to the second is effected from outside the cryogenic environment to vary the capacitance and hence the frequency of the resonant circuit formed by the superconducting devices.

Pang, C.S.; Falco, C.M.; Kampwirth, R.T.; Schuller, I.K.

1979-11-29T23:59:59.000Z

372

Information filtering via biased heat conduction  

E-Print Network (OSTI)

Heat conduction process has recently found its application in personalized recommendation [T. Zhou \\emph{et al.}, PNAS 107, 4511 (2010)], which is of high diversity but low accuracy. By decreasing the temperatures of small-degree objects, we present an improved algorithm, called biased heat conduction (BHC), which could simultaneously enhance the accuracy and diversity. Extensive experimental analyses demonstrate that the accuracy on MovieLens, Netflix and Delicious datasets could be improved by 43.5%, 55.4% and 19.2% compared with the standard heat conduction algorithm, and the diversity is also increased or approximately unchanged. Further statistical analyses suggest that the present algorithm could simultaneously identify users' mainstream and special tastes, resulting in better performance than the standard heat conduction algorithm. This work provides a creditable way for highly efficient information filtering.

Liu, Jian-Guo; Guo, Qiang

2011-01-01T23:59:59.000Z

373

Development of the Nested Fiber Filter  

SciTech Connect

Battelle, has tested the Nested Fiber Filter (NFF) as a particulate control device for high temperature, high-pressure (HTHP) applications. Battelle funded initial bench-scale tests which were the basis for patents and a concept applying the NFF. Subsequent parametric tests in a 6-inch diameter reactor established excellent particulate capture performance, > 99 percent, for conditions up to 1600 F and 6 atmospheres. Effective cleaning/regeneration of the NFF was achieved in the 6-inch scale with acoustic and mechanical vibration. A pulse combustor was tested in an integrated NFF arrangement because of compatibility with the HTBP conditions. This arrangement provided the basis for larger scale tests under the subject contract. A 6-ft[sup 2] test module was designed and installed with an existing fluidized bed combustor for additional development and testing.

Litt, R.D.; Conkle, H.N.; Raghavan, J.K.

1992-01-01T23:59:59.000Z

374

Submit Your Ideas for the NY Energy Data Jam | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Submit Your Ideas for the NY Energy Data Jam Submit Your Ideas for the NY Energy Data Jam Submit Your Ideas for the NY Energy Data Jam June 19, 2013 - 11:03am Q&A What idea would you present at the Data Jam? Join the Conversation Addthis Applications powered by open energy data were on display at the Energy Datapalooza in June 2012. | Photo by Sarah Gerrity, Energy Department. Applications powered by open energy data were on display at the Energy Datapalooza in June 2012. | Photo by Sarah Gerrity, Energy Department. Alex Cohen Alex Cohen Senior Digital Information Strategist How can I participate? Even if you cannot attend in person, we still want you to participate. Help us by starting the conversation. Email us at newmedia@hq.doe.gov and tell us your idea. Tweet questions to @ENERGY with the hashtag #EnergyJam.

375

Suggested Format for Submitting Frequency Data Requests to the Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Suggested Format for Submitting Frequency Data Requests to the Department of Energy Suggested Format for Submitting Frequency Data Requests to the Department of Energy This document provides a suggested format for 1710 - 1755 MHz wireless industry licensees to submit their data requests to the Department of Energy (DOE). Wireless licensees may use alternate formats, but should ensure that they indicate which DOE frequency assignments are being addressed by identifying the National Telecommunications and Information Administration (NTIA) Government Master File (GMS) Agency Serial Number. This is a unique identifier for each frequency assignment and will be in the format "DOE xxxxxx" where the "x's" will be numbers. XYZ Wireless Company requests the release of technical performance data related to the

376

Submitting the Report Deliverable via E-Link | Scientific and Technical  

Office of Scientific and Technical Information (OSTI)

Basics » DOE Reporting Requirements Basics » DOE Reporting Requirements Submitting the Report Deliverable via E-Link Print page Print page Email page Email page DOE Financial Assistance Recipients and Non-Major Site/Facility Management Contractor should use the AN 241.3 to submit scientific/technical reports electronically. No username or password is needed to submit the AN 241.3 or report deliverable. DOE awardees complete the web form AN 241.3 with just a few required pieces of information as indicated on the form in red font preceded by an asterisk. Instructions are linked at the top of the AN 241.3 and also at the data field level for each field. Set the browser to accept all cookies before starting the submission process. Be sure to input the DOE contract number accurately. Do not enter

377

Top U.S. Nuclear Official Commends Industry for Submitting 3rd Combined  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Top U.S. Nuclear Official Commends Industry for Submitting 3rd Top U.S. Nuclear Official Commends Industry for Submitting 3rd Combined Construction & Operating License Application to the NRC Top U.S. Nuclear Official Commends Industry for Submitting 3rd Combined Construction & Operating License Application to the NRC November 28, 2007 - 4:45pm Addthis RICHMOND, VA - The U.S. Department of Energy (DOE) Assistant Secretary for Nuclear Energy Dennis Spurgeon today commended Dominion North Anna, LLC (Dominion) for submission of a combined Construction and Operating License (COL) application to the Nuclear Regulatory Commission (NRC) for construction of a new nuclear power plant in the United States. Dominion's application seeks approval to build and operate one General Electric-Hitachi Economic Simplified Boiling Water Reactor (ESBWR) at its

378

Aerosys Agrees to Pay Civil Penalty and Submit Test Data in Settlement with  

NLE Websites -- All DOE Office Websites (Extended Search)

Aerosys Agrees to Pay Civil Penalty and Submit Test Data in Aerosys Agrees to Pay Civil Penalty and Submit Test Data in Settlement with DOE Aerosys Agrees to Pay Civil Penalty and Submit Test Data in Settlement with DOE July 6, 2010 - 3:08pm Addthis WASHINGTON, DC - The Department of Energy announced today that AeroSys, Inc. has agreed to pay a civil penalty of $25,000 and take a number of other actions designed to ensure its future compliance with DOE's energy efficiency standards. Last fall, the Department subpoenaed AeroSys's data on the energy use of certain heat pumps and air conditioners and then issued a demand to test 6 air conditioner models and one heat pump. DOE testing revealed that one heat pump model and two air conditioner models consumed more energy than allowed under federal efficiency standards and required AeroSys to cease distribution of those models. DOE also issued

379

ARM - Procedure for Submitting Science and Research Products to the Data  

NLE Websites -- All DOE Office Websites (Extended Search)

DocumentationProcedure for Submitting Science and Research DocumentationProcedure for Submitting Science and Research Products to the Data Archive Policies, Plans, Descriptions Data Documentation Home Data Sharing and Distribution Policy Data Management and Documentation Plan Data Product Registration and Submission Reading netCDF and HDF Data Files Time in ARM netCDF Data Files Data Archive Documentation ARM Archive's Catalog of Data Streams (Updated monthly) Access to Historical ARM Data More on Understanding and Finding ARM Data Data Quality Problem Reporting Procedure for Submitting Science and Research Products to the Data Archive The Principal Investigator (PI) establishes contact with an ARM Translator to describe the data product. The Translator collects enough information to describe the PI Product within the Translator group; thereby resulting in assignment of the

380

Submit Your Ideas for the NY Energy Data Jam | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Submit Your Ideas for the NY Energy Data Jam Submit Your Ideas for the NY Energy Data Jam Submit Your Ideas for the NY Energy Data Jam June 19, 2013 - 11:03am Q&A What idea would you present at the Data Jam? Join the Conversation Addthis Applications powered by open energy data were on display at the Energy Datapalooza in June 2012. | Photo by Sarah Gerrity, Energy Department. Applications powered by open energy data were on display at the Energy Datapalooza in June 2012. | Photo by Sarah Gerrity, Energy Department. Alex Cohen Alex Cohen Senior Digital Information Strategist How can I participate? Even if you cannot attend in person, we still want you to participate. Help us by starting the conversation. Email us at newmedia@hq.doe.gov and tell us your idea. Tweet questions to @ENERGY with the hashtag #EnergyJam.

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

How to Submit a Request for a PARS II Account | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

How to Submit a Request for a PARS II Account How to Submit a Request for a PARS II Account How to Submit a Request for a PARS II Account The account access process for PARS II relies on the Department of Energy's MIS Application Gateway system to verify the requestor's identity and to approve his/her request for access to a specific DOE Headquarters application, such as PARS II. Once approved by the MIS Application Gateway, the PARS II Help Desk Administrator will assign a new PARS II account to the requestor. Please follow the steps listed below to apply for a PARS II account. 1. If the federal employee or contractor does not already have an account with the Department of Energy's MIS Application Gateway, then the requestor must apply for an account and be approved by a local federal sponsor. To

382

EVALUATION OF ALTERNATIVE FILTER MEDIA FOR THE ROTARY MICROFILTER  

SciTech Connect

SRS is currently developing and testing several processes to treat high level radioactive liquid waste. These processes include the Integrated Salt Disposition Process (ISDP), the Salt Waste Processing Facility (SWPF), and the Small Column Ion Exchange Process (SCIX). Each of these processes has a solid-liquid separation process that limits its throughput. SRNL researchers identified and tested the rotary microfilter as a technology to increase solid-liquid separation throughput. The testing showed significant improvement in filter flux with the rotary microfilter over the baseline crossflow filter (i.e., 2.5-6.5X during scoping tests, as much as 10X in actual waste tests, and approximately 3X in pilot-scale tests). SRNL received funding from DOE EM-21, and subsequently DOE EM-31 to develop the rotary microfilter for high level radioactive service. The work has included upgrading the rotary microfilter for radioactive service, testing with simulated SRS waste streams, and testing it with simulated Hanford waste streams. While the filtration rate is better than that obtained during testing of crossflow filters, the authors believe the rotary microfilter throughput can be improved by using a better filter membrane. The rotary microfilter membrane is made of stainless steel (Pall PMM050). Previous testing, funded by DOE EM-21, showed that asymmetric filters composed of a ceramic membrane on top of a stainless steel support produced higher filter flux than 100% stainless steel symmetric filters in crossflow filter tests. In that testing, the Pall Accusep and Graver filters produced 13-21% larger filter flux than the baseline 0.1 {micro}m Mott filter. While the improvement in flux is not as dramatic as the improvement of the rotary filter over a crossflow filter, a 13-21% increase could reduce the lifetime of a 30 year process by 4-6 years, with significant cost savings. Subsequent rotary filter testing showed the Pall PMM050 stainless steel filter membrane produced higher flux than the Mott filter media in bench-scale and pilot-scale testing. The Accusep and Graver filter media were not evaluated in that testing, because they are not available as flat sheets. The Accusep filter was developed at ORNL and licensed to Pall Corporation. This filter has a stainless steel support structure with a zirconium oxide ceramic membrane. The pore size is 0.1 {micro}m absolute. The Graver filter has a stainless steel support structure with a titanium dioxide ceramic membrane. The pore size is 0.07 {micro}m absolute. SRNL and ORNL are working together to develop filter media similar to the Accusep and Graver media, and to test them in a bench-scale filtration apparatus to attempt to improve the throughput of the rotary microfilter. This report describes the effort.

Poirier, M.; Herman, D.; Bhave, R.

2011-09-13T23:59:59.000Z

383

Comparison of stochastic filtering methods for 3D tracking  

Science Conference Proceedings (OSTI)

In the recent years, the 3D visual research has gained momentum with publications appearing for all aspects of 3D including visual tracking. This paper presents a review of the literature published for 3D visual tracking over the past five years. The ... Keywords: 3D tracking, Articulated object tracking, Condensation algorithm, Kalman filter, Motion cue, Particle filter

Yasir Salih; Aamir Saeed Malik

2011-10-01T23:59:59.000Z

384

A recurrent fuzzy filter for the analysis of lung sounds  

Science Conference Proceedings (OSTI)

This paper presents a recurrent fuzzy-neural filter for real-time separation of discontinuous adventitious sounds from vesicular sounds. The filter uses two dynamic neuron-based fuzzy neural networks to perform the task of separation. The networks are ... Keywords: Discontinuous adventitious sounds, Dynamic neurons, Orthogonal least squares, Recurrent fuzzy-neural modeling, TSK fuzzy rules, Vesicular sounds

Paris A. Mastorocostas

2006-02-01T23:59:59.000Z

385

Ceramic filters for removal of particulates from hot gas streams  

Science Conference Proceedings (OSTI)

The primary goal is to demonstrate the performance of a new ceramic filter in removing particulate matter from hot gas streams produced in advanced coal conversion processes. The specific objectives are threefold: (1) Development of full size ceramic filters suitable for hot gas filtration; (2) Demonstration of ceramic filters in long term (ca. 1000 hrs) field trials; and (3) Development of full-scale hot gas filter system designs and costs. To date, field tests of the ceramic filter for particulate removal have been conducted at seven sites on a variety of gas streams and under a variety of test conditions. In general, the following performance characteristics have been observed: 1. Filtration face velocity (equivalent to an ``air to cloth ratio``) for flue gas tests is comparable to that for pulse jet bags operating at the same pressure drop. In hot gas tests, flow-pressure drop characteristics have been observed to be comparable to those for other ceramic filters. 2. Complete regeneration by a simple backpulse technique is achieved; i.e., no increase in clean filter resistance over repetitive cycles is observed. 3. No plugging of the filter passageways by badly caking particulates is observed. 4. Essentially complete particulate removal, including submicron particulate matter, is achieved.

Goldsmith, R.L.

1992-11-01T23:59:59.000Z

386

Ceramic filters for removal of particulates from hot gas streams  

Science Conference Proceedings (OSTI)

The primary goal is to demonstrate the performance of a new ceramic filter in removing particulate matter from hot gas streams produced in advanced coal conversion processes. The specific objectives are threefold: (1) Development of full size ceramic filters suitable for hot gas filtration; (2) Demonstration of ceramic filters in long term (ca. 1000 hrs) field trials; and (3) Development of full-scale hot gas filter system designs and costs. To date, field tests of the ceramic filter for particulate removal have been conducted at seven sites on a variety of gas streams and under a variety of test conditions. In general, the following performance characteristics have been observed: 1. Filtration face velocity (equivalent to an air to cloth ratio'') for flue gas tests is comparable to that for pulse jet bags operating at the same pressure drop. In hot gas tests, flow-pressure drop characteristics have been observed to be comparable to those for other ceramic filters. 2. Complete regeneration by a simple backpulse technique is achieved; i.e., no increase in clean filter resistance over repetitive cycles is observed. 3. No plugging of the filter passageways by badly caking particulates is observed. 4. Essentially complete particulate removal, including submicron particulate matter, is achieved.

Goldsmith, R.L.

1992-01-01T23:59:59.000Z

387

Autopoiesis, the immune system, and adaptive information filtering  

Science Conference Proceedings (OSTI)

Adaptive information filtering is a challenging and fascinating problem. It requires the adaptation of a representation of a user's multiple interests to various changes in them. We tackle this dynamic problem with Nootropia, a model inspired by the ... Keywords: Adaptive information filtering, Autopoiesis, Immune-inspired

Nikolaos Nanas; Anne Roeck

2009-06-01T23:59:59.000Z

388

Controlling access to the Internet: The role of filtering  

Science Conference Proceedings (OSTI)

Controlling access to the Internet by means of filtering software has become a growth industry in the U.S. and elsewhere. Its use has increased as the mandatory response to the current plagues of society, namely, pornography, violence, hate, and ... Keywords: Internet, United States, ethics, filters, free speech, laws, libraries

R. S. Rosenberg

2001-05-01T23:59:59.000Z

389

Biomass Control in Waste Air Biotrickling Filters by Protozoan Predation  

E-Print Network (OSTI)

Biomass Control in Waste Air Biotrickling Filters by Protozoan Predation Huub H. J. Cox, Marc A as a means of biomass control. Wet biomass for- mation in 23.6-L reactors over a 77-day period was reduced in the biotrickling filter enriched with protozoa. The lower rate of biomass accumulation after the addi- tion

390

Real-time personalized sports video filtering and summarization  

Science Conference Proceedings (OSTI)

We demonstrate a real-time fully automated software system for filtering important events in sports video. Events represent occurrences of actions or state changes in video content. In the current prototype, we demonstrate detection of pitching in baseball ... Keywords: MPEG-7, event detection, indexing, summarization, video filtering

Di Zhong; Raj Kumar; Shih-Fu Chang

2001-10-01T23:59:59.000Z

391

Trust network-based filtering of aggregated claims  

Science Conference Proceedings (OSTI)

On the semantic web, assertions may be aggregated from many sources, those aggregations filtered, reasoned over, aggregated with other aggregators, displayed, scraped, extracted, recombined, and otherwise processed without significant human oversight. ... Keywords: aggregated claims, assertions, information filtering, knowledge bases, ontologies, semantic web, social networks, source reputation, trust networks, trust rating, trustworthiness

Jennifer Golbeck; Bijan Parsia

2006-01-01T23:59:59.000Z

392

Difficult OptEase Filter Retrievals After Prolonged Indwelling Times  

SciTech Connect

PurposeThe OptEase vena cave filter (Cordis, Piscataway, NJ) is commercially available as a retrievable or permanent filter with short recommended indwelling time, presumably due to extensive contact of the filter side struts with the inferior vena cava wall and subsequent neointimal hyperplasia leading to incorporation. Our purpose was to evaluate OptEase filter retrievals with a long indwelling time period that required unconventional retrieval techniques.Materials and MethodsWe retrospectively reviewed patients who underwent OptEase filter retrieval with long undwelling times requiring additional maneuvers for retrieval. Techniques used included rigid endobronchial forceps dissection and wire-through-loop snare. Each patient underwent postretrieval venogram to evaluate for possible complications. In addition, patients had clinical follow-up 2 weeks after the retrieval procedure.ResultsThere were three patients (2 women, 1 man; average age 64 years) who underwent OptEase filter retrieval. The mean indwelling time was 6.4 months. The indwelling filters were successfully retrieved. There were no complications. Postprocedural follow-up showed no clinical pathology.ConclusionUnconventional techniques aided in the retrieval of OptEase filters with long indwelling times.

Van Ha, Thuong G., E-mail: tgvanha@radiology.bsd.uchicago.edu; Kang, Lisa; Lorenz, Jonathan; Zangan, Steven; Navuluri, Rakesh; Straus, Christopher; Funaki, Brian [University of Chicago, Section of Interventional Radiology, Department of Radiology (United States)

2013-08-01T23:59:59.000Z

393

Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor -Global  

E-Print Network (OSTI)

PENNSTATE Department of Mechanical Engineering Spring 2012 HVAC Filter Sensor - Global Overview The purpose of this project is to develop a heating, ventilation, and air conditioning (HVAC) monitoring a residential, forced flow, multi-zone HVAC filter needs to be replaced, and then alerts the users

Demirel, Melik C.

394

Parallelized sigma-point Kalman filtering for structural dynamics  

Science Conference Proceedings (OSTI)

In this paper, the sigma-point Kalman filter (S-PKF) is adopted to track the state of composite structures undergoing impact-induced delamination. Estimates provided by the S-PKF are obtained through a set of sigma-points, which independently evolve ... Keywords: Composite delamination, Interface models, Kalman filter, Nonlinear dynamics, Sigma-point (unscented) transformation

Saeed Eftekhar Azam; Aldo Ghisi; Stefano Mariani

2012-02-01T23:59:59.000Z

395

Understanding the efficacy of deployed internet source address validation filtering  

Science Conference Proceedings (OSTI)

IP source address forgery, or "spoofing," is a long-recognized consequence of the Internet's lack of packet-level authenticity. Despite historical precedent and filtering and tracing efforts, attackers continue to utilize spoofing for anonymity, indirection, ... Keywords: filtering, ip spoofing, source address validation

Robert Beverly; Arthur Berger; Young Hyun; k claffy

2009-11-01T23:59:59.000Z

396

Electrostatic precipitators vs. fabric filters: A symposium and debate  

SciTech Connect

Nine papers were presented at the Electrostatic Precipitators vs. Fabric Filters: A Symposium and Debate held March 22, 1994 at the Sheraton Crystal City Hotel in Arlington, Virginia. The Symposium was intended to take a frank look at the comparative advantages of electrostatic precipitators and fabric filters. A separate abstract was prepared for each paper for inclusion in the Energy Science and Technology Database.

1994-12-31T23:59:59.000Z

397

A Collaborative Filtering Algorithm Based on Global and Domain Authorities  

Science Conference Proceedings (OSTI)

Collaborative filtering has been very successful in both applications and researches. In real situation, different users may have different influences on other users' decisions. Those authoritative users usually play more important roles. But few existing ... Keywords: Collaboration Filtering, Domain Authority, Global Authority

Li Zhou; Yong Zhang; Chun-Xiao Xing

2008-12-01T23:59:59.000Z

398

A unified optimization framework for equalization filter synthesis  

Science Conference Proceedings (OSTI)

We present a novel method for jointly optimizing FIR filters for pre-equalization, decision feedback equalization, and near-end crosstalk cancellation. The unified optimization problem is a linear program, and we describe sparse matrix techniques for ... Keywords: crosstalk, equalizing filters, linear programming, optimal synthesis

Jihong Ren; Mark Greenstreet

2005-06-01T23:59:59.000Z

399

A polyphase filter for GPUs and multi-core processors  

Science Conference Proceedings (OSTI)

Software radio telescopes are a new development in radio astronomy. Rather than using expensive dishes, they form distributed sensor networks of tens of thousands of simple receivers. Signals are processed in software instead of custom-built hardware, ... Keywords: CUDA, FIR filter, LOFAR, MicroGrid, OpenCL, digital signal processing, polyphase filter, radio astronomy

Karel van der Veldt; Rob van Nieuwpoort; Ana Lucia Varbanescu; Chris Jesshope

2012-06-01T23:59:59.000Z

400

A Sequential Ensemble Kalman Filter for Atmospheric Data Assimilation  

Science Conference Proceedings (OSTI)

An ensemble Kalman filter may be considered for the 4D assimilation of atmospheric data. In this paper, an efficient implementation of the analysis step of the filter is proposed. It employs a Schur (elementwise) product of the covariances of the ...

P. L. Houtekamer; Herschel L. Mitchell

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Absolute Glovebox Ventilation Filtration System with Unique Filter Replacement Feature  

SciTech Connect

A glovebox ventilation system was designed for a new plutonium-238 processing facility that provided 1) downdraft ventilation, 2) a leak tight seal around the High Efficiency Particulate Air (HEPA) filters, and 3) a method for changing the filters internally without risk of contaminating the laboratory.

Freeman, S. S.; Slusher, W. A.

1975-12-31T23:59:59.000Z

402

Weighted median filters with sigma-delta modulation encoding  

Science Conference Proceedings (OSTI)

Digital decimation filters play a fundamental role in oversampled sigma-delta A/D decoders. In this paper, we first show that weighted median (WM) filtering of a demodulated sequence (at the Nyquist rate) can be implemented concurrently in the A/D decoder. ...

G.R. Arce; N.A. Grabowski; N.C. Gallagher

2000-02-01T23:59:59.000Z

403

BES_NERSC_Wang.ppt  

NLE Websites -- All DOE Office Websites (Extended Search)

A
DFT
nanostructure
calcula0on
 A
DFT
nanostructure
calcula0on
 case
study
 Lin-Wang
Wang
 Lawrence
Berkeley
Na0onal
Lab
 For BES/NERSC large scale simulation workshop A summary of mp304 NERSC account  Allocated and used computer time in 2009: ~ 1 M hours  Total number of users: ~ 7 active users  Main codes used: VASP, LAMMP, Petot, Escan, LS3DF  Number of topics (number of published papers): ~ 15  Number of processors for typical jobs: 16 to 1000, sometimes 10,000  Duration of the jobs: 20 minutes, to several hours, to a few days  The main considerations which determine the jobs we run: the physics problem, queue time and computer time.  Other facilities: no group cluster, INCITE project at NCCS and ALCF (but not discussed here).

404

Wang et al 2011.pdf  

NLE Websites -- All DOE Office Websites (Extended Search)

SV, Pavlostathis SG, Rozzi A, Sanders WTM, Siegrist H, Vavilin VA (2001) The IWA Anaerobic Digestion Model No. 1 (ADM1). IWA Publishing, London, U.K. Burrell PC,...

405

Chih-Ming (Jack) Wang  

Science Conference Proceedings (OSTI)

... of polarization dependent loss of fiber ... nm for combined photodiode/rf power sensor transfer ... Statistical analysis of network analyzer measurements ...

2010-10-04T23:59:59.000Z

406

Jianhui Wang | Argonne National Laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

- Energy Systems. His research interests include power system operations and control; optimization; smart grid; renewable integration; energy economics and policy;...

407

Cascaded warped-FIR and FIR filter structure for loudspeaker equalization with low computational cost requirements  

Science Conference Proceedings (OSTI)

This paper proposes an improved filter structure and methodology for the equalization of loudspeakers and other audio systems. It employs a cascaded structure of a finite impulse response (FIR) filter and a warped-FIR filter in order to obtain the best ... Keywords: FIR filters, Loudspeaker equalization, Low computational cost, Warped filters

Germn Ramos; Jos J. Lpez; Basilio Pueo

2009-05-01T23:59:59.000Z

408

DEVELOPMENT OF A CANDLE FILTER FAILURE SAFEGUARD DEVICE  

SciTech Connect

The full-flow mechanical safeguard device (FFMSGD) has been developed under contract to the National Energy Technology Laboratory (NETL) to address problems with the reliability of ceramic candle filter elements installed on high-temperature, high-pressure (HTHP) Hot Gas Cleanup (HGCU) filters. Although systems candle filters are expected to perform satisfactorily when in good operating condition, the failure of even a single filter element can increase the filter system outlet dust loading enough to potentially damage gas turbine blades, contaminate other downstream processes, and limit the availability of the power system. Filter failure safeguard devices that are installed on each individual candle filter element are envisioned as a guarantee of a candle filter system's ability to withstand some number of element failures and continue operation without these negative consequences. The intention of the FFMSGD is to provide this guarantee without incurring any significant pressure drop penalty or constraining the filter system's reverse-pulse cleaning procedures. The FFMSGD provides a clear flow path for filtered and reverse-flow cleaning gases when its filter element is intact, and activates to provide a positive mechanical seal against gas flow in either direction when its filter element breaks or fails. This activation is induced by the increase in the flow rate of gas through the device in event of filter failure. The FFMSGD is designed to be easily removed and reconditioned when the filter system is taken off line for routine maintenance. This report is intended to be issued with a companion appendix. As instructed in Section J.12 of Contract No. DE-AC26-99FT40678, all the restricted, proprietary, and patentable information (not yet disclosed through the patent application process) related to the FFMSGD and its evaluation under this contract has been included only in the appendix. This Final Report, which is available to the public, contains background information and general descriptions of the operating principles of the FFMSGD. This report also describes the results of various evaluations of the device at room temperature and in HTHP environments. This Final Report also includes discussions of commercialization issues. For clarity and completeness, all of the information contained in this Final Report has also been included in the appendix.

Todd R. Snyder

2002-03-29T23:59:59.000Z

409

Secondary pollutants from ozone reactions with ventilation filters and  

NLE Websites -- All DOE Office Websites (Extended Search)

Secondary pollutants from ozone reactions with ventilation filters and Secondary pollutants from ozone reactions with ventilation filters and degradation of filter media additives Title Secondary pollutants from ozone reactions with ventilation filters and degradation of filter media additives Publication Type Journal Article Year of Publication 2011 Authors Destaillats, Hugo, Wenhao Chen, Michael G. Apte, Nuan Li, Michael Spears, Jérémie Almosni, Gregory Brunner, Jianshun(Jensen) Zhang, and William J. Fisk Journal Atmospheric Environment Volume 45 Start Page 3561 Issue 21 Pagination 3561-3568 Keywords commercial building ventilation & indoor environmental quality group, commercial building ventilation and indoor environmental quality group, energy analysis and environmental impacts department, indoor environment department, indoor environment group

410

Development of ceramic composite hot-gas filters  

SciTech Connect

A novel type of hot-gas filter based on a ceramic fiber-reinforced ceramic matrix was developed and extended to fullsize, 60-mm OD by 1.5-meter-long, candle filters. A commercially viable process for producing the filters was developed, and the filters are undergoing testing and demonstration throughout the world for applications in pressurized fluidized-bed combustion (PFBC) and integrated gasification combined cycle (IGCC) plants. Development activities at Oak Ridge National Laboratory (ORNL) and at the 3M Company, and testing at the Westinghouse Science and Technology Center (STC) are presented. Demonstration tests at the Tidd PFBC are underway. Issues identified during the testing and demonstration phases of the development are discussed. Resolution of the issues and the status of commercialization of the filters are described.

Judkins, R.R.; Stinton, D.P. [Oak Ridge National Lab., TN (United States); Smith, R.G.; Fischer, E.M.; Eaton, J.H.; Weaver, B.L.; Kahnke, J.L.; Pysher, D.J. [3M Co., St. Paul, MN (United States)

1995-04-01T23:59:59.000Z

411

A thermovoltaic semiconductor device including a plasma filter  

DOE Patents (OSTI)

A thermovoltaic energy conversion device and related method for converting thermal energy into an electrical potential are disclosed. An interference filter is provided on a semiconductor thermovoltaic cell to pre-filter black body radiation. The semiconductor thermovoltaic cell includes a P/N junction supported on a substrate which converts incident thermal energy below the semiconductor junction band gap into electrical potential. The semiconductor substrate is doped to provide a plasma filter which reflects back energy having a wavelength which is above the band gap and which is ineffectively filtered by the interference filter, through the P/N junction to the source of radiation thereby avoiding parasitic absorption of the unusable portion of the thermal radiation energy.

Baldasaro, Paul F.

1997-12-01T23:59:59.000Z

412

Polarization-independent optical wavelength filter for channel dropping applications  

DOE Patents (OSTI)

The polarization dependence of optical wavelength filters is eliminated by using waveguide directional couplers. Material birefringence is used to compensate for the waveguide (electromagnetic) birefringence which is the original cause of the polarization dependence. Material birefringence is introduced in a controllable fashion by replacing bulk waveguide layers by finely layered composites, such as multiple quantum wells using III-V semiconductor materials. The filter has use in wavelength-division-multiplexed fiber optic communication systems. This filter has broad application for wavelength-tunable receivers in fiber optic communication links, which may be used for telecommunications, optical computer interconnect links, or fiber optic sensor systems. Since multiple-wavelength systems are increasingly being used for all of these applications, the filter is useable whenever a rapidly tunable, wavelength-filtering receiver is required.

Deri, Robert J. (Pleasanton, CA); Patterson, Frank (Livermore, CA)

1996-01-01T23:59:59.000Z

413

Filtering with Marked Point Process Observations via Poisson Chaos Expansion  

SciTech Connect

We study a general filtering problem with marked point process observations. The motivation comes from modeling financial ultra-high frequency data. First, we rigorously derive the unnormalized filtering equation with marked point process observations under mild assumptions, especially relaxing the bounded condition of stochastic intensity. Then, we derive the Poisson chaos expansion for the unnormalized filter. Based on the chaos expansion, we establish the uniqueness of solutions of the unnormalized filtering equation. Moreover, we derive the Poisson chaos expansion for the unnormalized filter density under additional conditions. To explore the computational advantage, we further construct a new consistent recursive numerical scheme based on the truncation of the chaos density expansion for a simple case. The new algorithm divides the computations into those containing solely system coefficients and those including the observations, and assign the former off-line.

Sun Wei, E-mail: wsun@mathstat.concordia.ca [Concordia University, Department of Mathematics and Statistics (Canada); Zeng Yong, E-mail: zengy@umkc.edu [University of Missouri at Kansas City, Department of Mathematics and Statistics (United States); Zhang Shu, E-mail: zhangshuisme@hotmail.com [Concordia University, Department of Mathematics and Statistics (Canada)

2013-06-15T23:59:59.000Z

414

NETL: Gasification - Long-Term Candle Filter Tests  

NLE Websites -- All DOE Office Websites (Extended Search)

Long-Term Candle Filter Tests Long-Term Candle Filter Tests National Carbon Capture Center at the Power Systems Development Facility Southern Company Services, Inc. Project Number: NT0000749 Project Description The National Carbon Capture Center advancement of hot gas filtration technology provides the design for optimal, long-term evaluation of material performance for particulate control device (PCD) filter elements. Testing is performed using the commercially available Siemens PCD, due to its demonstrated excellent collection efficiency during normal operation. The PCD, located downstream of the primary gas cooler, houses up to 91 candle-type filter elements. They're currently used in the development of candle filters that can efficiently remove particulates at varying temperatures, using low-cost materials and innovative design.

415

Polarization-independent optical wavelength filter for channel dropping applications  

DOE Patents (OSTI)

The polarization dependence of optical wavelength filters is eliminated by using waveguide directional couplers. Material birefringence is used to compensate for the waveguide (electromagnetic) birefringence which is the original cause of the polarization dependence. Material birefringence is introduced in a controllable fashion by replacing bulk waveguide layers by finely layered composites, such as multiple quantum wells using III-V semiconductor materials. The filter has use in wavelength-division multiplexed fiber optic communication systems. This filter has broad application for wavelength-tunable receivers in fiber optic communication links, which may be used for telecommunications, optical computer interconnect links, or fiber optic sensor systems. Since multiple-wavelength systems are increasingly being used for all of these applications, the filter is useable whenever a rapidly tunable, wavelength-filtering receiver is required. 14 figs.

Deri, R.J.; Patterson, F.

1996-05-07T23:59:59.000Z

416

METAL FILTERS FOR PRESSURIZED FLUID BED COMBUSTION (PFBC) APPLICATIONS  

SciTech Connect

Advanced coal and biomass-based gas turbine power generation technologies (IGCC, PFBC, PCFBC, and Hipps) are currently under development and demonstration. Efforts at the Siemens Westinghouse Power Corporation (SWPC) have been focused on the development and demonstration of hot gas filter systems as an enabling technology for power generation. As part of the demonstration effort, SWPC has been actively involved in the development of advanced filter materials and component configuration, has participated in numerous surveillance programs characterizing the material properties and microstructure of field-tested filter elements, and has undertaken extended, accelerated filter life testing programs. This report reviews SWPC's material and component assessment efforts, identifying the performance, stability, and life of porous commercial metal, advanced alloy, and intermetallic filters under simulated, pressurized fluidized-bed combustion (PFBC) conditions.

M.A. Alvin

2004-01-02T23:59:59.000Z

417

Development of ceramic composite hot-gas filters  

SciTech Connect

A novel type of hot-gas filter based on a ceramic fiber-reinforced ceramic matrix was developed and extended to full-size, 60-mm OD by 1.5-m-long, candle filters. A commercially viable process for producing the filters was developed, and the filters are undergoing testing and demonstration throughout the world for applications in pressurized fluidized-bed combustion (PFBC) and integrated gasification combined cycle (IGCC) plants. Development activities at Oak Ridge National Laboratory (ORNL) and at the 3M Company, and testing at the Westinghouse Science and Technology Center (STC) are presented. Demonstration tests at the Tidd PFBC are in progress. Issues identified during the testing and demonstration phases of the development are discussed. Resolution of the issues identified during testing and the status of commercialization of the filters are described.

Judkins, R.R.; Stinton, D.P. [Oak Ridge National Lab., TN (United States); Smith, R.G.; Fischer, E.M.; Eaton, J.H.; Weaver, B.L.; Kahnke, J.L.; Pysher, D.J. [3M Co., St. Paul, MN (United States)

1996-07-01T23:59:59.000Z

418

Physics of a magnetic filter for negative ion sources. I. Collisional transport across the filter in an ideal, 1D filter  

Science Conference Proceedings (OSTI)

Magnetic filters are used in negative ion sources for neutral beam injection in fusion devices to reduce the electron temperature in the extraction region in order to limit negative ion destruction by fast electrons. The drop in electron temperature through the filter is due to the enhanced residence time and collisional energy losses of electrons trapped in the magnetic field. The mechanisms controlling particle and energy transport through the magnetic filter in negative ion sources of the ITER type are still not clear and the aim of this paper is to clarify and quantify these mechanisms. A particle-in-cell Monte Carlo simulation is used to revisit and analyze the role and operation of the magnetic filter in an 'ideal' one-dimensional configuration and to study the stability of the one-dimensional solution in a two-dimensional configuration with periodic boundary conditions. The roles of collisions and instabilities on electron transport through the filter are discussed. The influence of a more realistic geometry on electron transport through the filter is analyzed in the companion paper [Boeuf et al., Phys. Plasmas 19, 113510 (2012)].

Boeuf, J. P.; Chaudhury, B.; Garrigues, L. [LAboratoire PLAsma et Conversion d'Energie (LAPLACE), Universite de Toulouse, Bt. 3R2, 118 Route de Narbonne, F-31062 Toulouse Cedex 9 (France)

2012-11-15T23:59:59.000Z

419

Optease Vena Cava Filter Optimal Indwelling Time and Retrievability  

SciTech Connect

The purpose of this study was to assess the indwelling time and retrievability of the Optease IVC filter. Between 2002 and 2009, a total of 811 Optease filters were inserted: 382 for prophylaxis in multitrauma patients and 429 for patients with venous thromboembolic (VTE) disease. In 139 patients [97 men and 42 women; mean age, 36 (range, 17-82) years], filter retrieval was attempted. They were divided into two groups to compare change in retrieval policy during the years: group A, 60 patients with filter retrievals performed before December 31 2006; and group B, 79 patients with filter retrievals from January 2007 to October 2009. A total of 128 filters were successfully removed (57 in group A, and 71 in group B). The mean filter indwelling time in the study group was 25 (range, 3-122) days. In group A the mean indwelling time was 18 (range, 7-55) days and in group B 31 days (range, 8-122). There were 11 retrieval failures: 4 for inability to engage the filter hook and 7 for inability to sheathe the filter due to intimal overgrowth. The mean indwelling time of group A retrieval failures was 16 (range, 15-18) days and in group B 54 (range, 17-122) days. Mean fluoroscopy time for successful retrieval was 3.5 (range, 1-16.6) min and for retrieval failures 25.2 (range, 7.2-62) min. Attempts to retrieve the Optease filter can be performed up to 60 days, but more failures will be encountered with this approach.

Rimon, Uri, E-mail: rimonu@sheba.health.gov.il; Bensaid, Paul, E-mail: paulbensaid@hotmail.com; Golan, Gil, E-mail: gilgolan201@gmail.com; Garniek, Alexander, E-mail: garniek@gmail.com; Khaitovich, Boris, E-mail: borislena@012.net.il [Chaim Sheba Medical Center (Affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv), Department of Diagnostic Imaging (Israel); Dotan, Zohar, E-mail: Zohar.Dotan@sheba.health.gov.il [Chaim Sheba Medical Center (Affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv), Department of Urology (Israel); Konen, Eli, E-mail: Eli.Konen@sheba.health.gov.il [Chaim Sheba Medical Center (Affiliated to the Sackler School of Medicine, Tel-Aviv University, Tel-Aviv), Department of Diagnostic Imaging (Israel)

2011-06-15T23:59:59.000Z

420

Development of NDE methods for hot gas filters.  

SciTech Connect

Ceramic hot gas candle filters are currently under development for hot gas particulate cleanup in advanced coal-based power systems. The ceramic materials for these filters include nonoxide monolithic, nonoxide-fiber-reinforced composites, and nonoxide reticulated foam. A concern is the lack of reliable data on which to base decisions for reusing or replacing hot gas filters during plant shutdowns. The work in this project is aimed at developing nondestructive evaluation (FIDE) technology to allow detection, and determination of extent, of life-limiting characteristics such as thermal fatigue, oxidation, damage from ash bridging such as localized cracking, damage from local burning, and elongation at elevated temperature. Although in-situ NDE methods are desirable in order to avoid disassembly of the candle filter vessels, the current vessel designs, the presence of filter cakes and possible ash bridging, and the state of NDE technology prevent this. Candle filter producers use a variety of NDE methods to ensure as-produced quality. While impact acoustic resonance offers initial promise for examining new as-produced filters and for detecting damage in some monolithic filters when removed from service, it presents difficulties in data interpretation, it lacks localization capability, and its applicability to composites has yet to be demonstrated. Additional NDE technologies being developed and evaluated in this program and whose applicability to both monolithics and composites has been demonstrated include (a) full-scale thermal imaging for analyzing thermal property variations; (b) fret, high-spatial-resolution X-ray imaging for detecting density variations and dimensional changes; (c) air-coupled ultrasonic methods for determining through-thickness compositional variations; and (d) acoustic emission technology with mechanical loading for detecting localized bulk damage. New and exposed clay-bonded SiC filters and CVI-SiC composite filters have been tested with these additional NDE methods.

Deemer, C.; Ellingson, W. A.; Koehl, E. R.; Lee, H.; Spohnholtz, T.; Sun, J. G.

1999-07-21T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

A Comparison of Hybrid Ensemble Transform Kalman FilterOptimum Interpolation and Ensemble Square Root Filter Analysis Schemes  

Science Conference Proceedings (OSTI)

A hybrid ensemble transform Kalman filter (ETKF)optimum interpolation (OI) analysis scheme is described and compared with an ensemble square root filter (EnSRF) analysis scheme. A two-layer primitive equation model was used under perfect-model ...

Xuguang Wang; Thomas M. Hamill; Jeffrey S. Whitaker; Craig H. Bishop

2007-03-01T23:59:59.000Z

422

TESTING OF THE SECOND GENERATION SPINTEK ROTARY FILTER -11357  

SciTech Connect

The SpinTek rotary microfilter has been developed under the Department of Energy (DOE) Office of Environmental Management (EM) for the purpose of deployment in radioactive service in the DOE complex. The unit that was fabricated and tested is the second generation of the filter that incorporates recommended improvements from previous testing. The completion of this test satisfied a key milestone for the EM technology development program and technology readiness for deployment by Savannah River Remediation in the Small Column Ion Exchange and Sludge Washing processes at the Savannah River Site (SRS). The Savannah River National Laboratory (SRNL) contracted SpinTek Filtration to fabricate a full scale 25 disk rotary filter and perform a 1000 hour endurance test with a simulated SRS sludge. Over 1500 hours of operation have been completed with the filter. SpinTek Filtration fabricated a prototypic 25 disk rotary filter including updates to manufacturing tolerances, an updated design to the rotary joint, improved cooling to the bottom journal, decreases in disk and filter shaft hydraulic resistances. The filter disks were fabricated with 0.5 {micro} pore size, sintered-metal filter media manufactured by Pall Corporation (M050). After fabrication was complete, the filter passed acceptance tests demonstrating rejection of solids and clean water flux with a 50% improvement over the previous filters. Once the acceptance test was complete, a 1000 hour endurance test was initiated simulating a sludge washing process. The test used a simulated SRS Sludge Batch 6 recipe. The insoluble solids started at 5 wt% and were raised to 10 and 15 wt% insoluble solids to simulate the concentration of a large volume tank. The filter system was automated and set up for 24 hour unattended operation. To facilitate this, process control logic was written to operate the filter. During the development it was demonstrated that the method of starting and stopping the filter can affect the build up of filter cake on the disks and therefore the performance of the filter. The filter performed well with the simulant. Very little drop in production was noticed between the 5 and 10 wt% insoluble solids feed. Increasing to 15 wt% had a more pronounced impact due to the rheology of the feed. Acid cleaning was used to clean the filter disks in-situ and restore filtration rate to almost 90% of the initial clean disk rate. Eighty liters of 0.2 M nitric acid in conjunction with water rinses were used to clean the filter in less than 2 hours. Filter testing was completed after 1000 hours of operation were performed on the final filter assembly configuration. The total run time for the testing was over 1500 hours. At the end of the test, the sludge washing was performed successfully from approximately 5.6 M to less than 1 M sodium.

Herman, D.; Poirier, M.; Fowley, M.; Keefer, M.; Huff, T.

2011-02-02T23:59:59.000Z

423

Instructions for Submitting Document to OpenNet | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Instructions for Submitting Document to OpenNet Instructions for Submitting Document to OpenNet Instructions for Submitting Document to OpenNet Requesting an account to submit documents to OpenNet If you plan to load documents to OpenNet, you must have an OpenNet Logon Name and Password. If you don't already have one, go to the OpenNet web site at: http://www.osti.gov/opennet. Click on the LOGIN link on the top right. Read the information and check the "I agree..." box. Click on the "Request data submission access..." link at the bottom of the page. Fill out the form. One of the required fields is the Site Input Code field. This field provides a drop down list of DOE Sites. All users with the same Site Input Code can edit all the records for that site. If your Site Code is not in the list or you need a site code more specific to your office than those

424

Scientometric analysis of papers submitted to the third international nanotechnology forum (Moscow, 2010)  

Science Conference Proceedings (OSTI)

This is a brief information and analytical survey of the papers that were submitted to the Third International Nanotechnology Forum that was held in Moscow on November 1---3, 2010. Scientometric data on the participants, their origins by region and research ... Keywords: Nanotechnology Forum, Nobel Prize winners, RUSNANO, education, graphene, nanomaterials, nanoobjects, nanophysics, nanostructure, scientometrics

N. M. Builova; A. I. Osipov

2011-02-01T23:59:59.000Z

425

Oil Independence: Achievable National Goal or Empty Slogan? Submitted May 25, 2007  

E-Print Network (OSTI)

07--1693 Oil Independence: Achievable National Goal or Empty Slogan? Submitted May 25, 2007 Word-488-2413; email: singhm@anl.gov #12;Greene, Leiby, Patterson, Plotkin and Singh 1 ABSTRACT Oil independence has. A rigorous, measurable definition is proposed: to reduce the costs of oil dependence to less than 1% of GDP

426

Computational Modeling and the Experimental Plasma Research Program A White Paper Submitted to the FESAC Subcommittee  

E-Print Network (OSTI)

Computational Modeling and the Experimental Plasma Research Program A White Paper Submitted of the fusion energy program. The experimental plasma research (EPR) program is well positioned to make major in fusion development and promote scientific discovery. Experimental plasma research projects explore

427

Agent Tcl: A exible and secure mobile-agent Submitted to the Faculty  

E-Print Network (OSTI)

Agent Tcl: A exible and secure mobile-agent system A Thesis Submitted to the Faculty in partial ful malicious machines), and insulating the agent against network and machine failures. Agent Tcl is a mobile-agent system under development at Dartmouth College that has evolved from a Tcl-only system into a multiple

428

Agent Tcl: A flexible and secure mobileagent Submitted to the Faculty  

E-Print Network (OSTI)

Agent Tcl: A flexible and secure mobile­agent system A Thesis Submitted to the Faculty in partial malicious machines), and insulating the agent against network and machine failures. Agent Tcl is a mobile­agent system under development at Dartmouth College that has evolved from a Tcl­only system into a multiple

429

SOM ARRA Grant Activity Proposals Submitted as of 7-15-2010 Project Costs*  

E-Print Network (OSTI)

SOM ARRA Grant Activity Proposals Submitted as of 7-15-2010 Project Costs* Total # of Proposals 1,264 Total Project Costs $1,093,036,719 Total Direct Costs $803,739,425 Total Indirects $290,408,131 Awards Received as of 2-11-2011 Project Costs* Year 1 Costs Total # of Awards 333 Total Project Costs $186

Bushman, Frederic

430

An introduction to ios programming: from getting the sdk to submitting your first app, 1 edition  

Science Conference Proceedings (OSTI)

Learn the steps necessary for building your first iOS app. With this introductory video course, experienced iOS developer Alasdair Allan walks you through the entire process, from downloading the developer tools to submitting your finished app to Apple's ...

Allan Alasdair

2011-05-01T23:59:59.000Z

431

Submitted 08-13-09: Energy Policy Putting Renewables and Energy Efficiency To Work  

E-Print Network (OSTI)

energy usage due to other effects such as conservation or behavior changes. The supply of low carbon1 Submitted 08-13-09: Energy Policy Putting Renewables and Energy Efficiency To Work: How Many Jobs Can The Clean Energy Industry Generate in the U.S.? Max Wei,* Shana Patadia,** Daniel M. Kammen

Kammen, Daniel M.

432

Scientometric analysis of papers submitted to the second international nanotechnology forum (Moscow, 2009)  

Science Conference Proceedings (OSTI)

This is a brief information and analytical survey of the papers submitted to the Second International Nanotechnology Forum held in Moscow in October 2009. Scientometric data on the participants, their origins by regions and research centers, as well ... Keywords: Nanotechnology Forum, ROSNANO, education, nanomaterials nanometrology, nanoobjects, nanophysics, scientometrics

N. M. Builova; A. I. Osipov

2010-04-01T23:59:59.000Z

433

Carbon Dioxide Footprint of the Northwest Power System Comments submitted by Grant County Public Utility District  

E-Print Network (OSTI)

Carbon Dioxide Footprint of the Northwest Power System Comments submitted by Grant County Public paper: Carbon Dioxide Footprint of the Northwest Power System, dated September 13, 2007. The Grant done a very thorough job of assessing the current and future carbon dioxide footprints of the Northwest

434

Design and manufacture of a low-cost mechanism for compacting used oil filters  

E-Print Network (OSTI)

Used automotive oil filter disposal is a real and increasing problem in the United States. With over 450 million oil filters sold each year, and 80% of used filters thrown into landfills, this waste represents a significant ...

Kosoglow, Richard D

2008-01-01T23:59:59.000Z

435

Adaptive Sampling with the Ensemble Transform Kalman Filter. Part I: Theoretical Aspects  

Science Conference Proceedings (OSTI)

A suboptimal Kalman filter called the ensemble transform Kalman filter (ET KF) is introduced. Like other Kalman filters, it provides a framework for assimilating observations and also for estimating the effect of observations on forecast error ...

Craig H. Bishop; Brian J. Etherton; Sharanya J. Majumdar

2001-03-01T23:59:59.000Z

436

Design of fuel efficient brick kiln for ceramic water filter firing in Ghana  

E-Print Network (OSTI)

Ceramic water filters are currently produced in Ghana in order to provide a household solution to contaminated water. These filters, locally branded with the name Kosim filter by originating from Potters for Peace-Nicaragua, ...

Adjorlolo, Eric (Eric James Kofi)

2007-01-01T23:59:59.000Z

437

Development of a Fan-Filter Unit Test Standard, Laboratory Validations, and its Applications across Industries  

E-Print Network (OSTI)

Energy Performance of Fan-Filter Units, Version 1.3 (2005).Energy Performance of Fan-Filter Units, Version 2.0 (2006).Evaluation of Fan-filter Units Aerodynamic and Energy

Xu, Tengfang

2008-01-01T23:59:59.000Z

438

Development of a Fan-Filter Unit Test Standard, Laboratory Validations, and its Applications across Industries  

E-Print Network (OSTI)

Energy Performance of Fan-Filter Units, Version 1.3 (2005).Energy Performance of Fan-Filter Units, Version 2.0 (2006).Laboratory Evaluation of Fan-filter Units Aerodynamic and

Xu, Tengfang

2008-01-01T23:59:59.000Z

439

Standard Methods of Characterizing Performance of Fan Filter Units, Version 3.0  

E-Print Network (OSTI)

Efficient Filtration: Fan-filter Units. Final Report,Xu. 2007. The Development of Fan Filter Unit with Flow Rate2007. Performance of Large Fan Filter Units for Cleanroom

Xu, Tengfang

2007-01-01T23:59:59.000Z

440

Tests to determine effect of humidity on high-efficiency filters when installed horizontally  

SciTech Connect

The object of tests is to determine effect of high-humidity air on the physical characteristics of filter media and separators when the filter is mounted in the horizontal position. Usual installation is with the filter mounted vertically.

Palmer, J.H.

1960-10-04T23:59:59.000Z

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Improved Spatial Filter for high power Lasers  

DOE Patents (OSTI)

A new pinhole architecture incorporates features intended to reduce the rate of plasma generation in a spatial filter for high-energy laser pulse beams. An elongated pinhole aperture is provided in an apertured body for rejecting off-axis rays of the laser pulse beam. The internal surface of the elongated aperture has a diameter which progressively tapers from a larger entrance cross-sectional area at an inlet to a smaller output cross-sectional area at an outlet. The tapered internal surface causes off-axis rays to be refracted in a low density plasma layer that forms on the internal surface or specularly reflected at grazing incidence from the internal surface. Off-axis rays of the high-energy pulse beam are rejected by this design. The external surface of the apertured body adjacent to the larger entrance cross-sectional area at the inlet to the elongated aperture is angled obliquely with respect to the to direction of the path of the high-energy laser pulse beam to backscatter off-axis rays away from the high-energy pulse beam. The aperture is formed as a truncated cone or alternatively with a tapered square cross-section. The internal surface of the aperture is coated with an ablative material, preferably high-density material which can be deposited with an exploding wire.

Estabrook, Kent G.; Celliers, Peter M.; Murray, James E.; DaSilva, Luiz; MacGowan, Brian J.; Rubenchik, Alexander M.; Manes, Kenneth R.; Drake, Robert P.; Afeyan, Bedros

1998-06-01T23:59:59.000Z

442

Westinghouse standleg moving granular bed filter development program  

SciTech Connect

Advanced, coal-based, power plants, such as IGCC and Advanced-PFBC, are currently nearing commercial demonstration. These power plant technologies require hot gas filtration as part of their gas cleaning trains. Ceramic barrier filters are the major filter candidates being developed for these hot gas cleaning applications. While ceramic barrier filters achieve high levels of particle removal, there are concerns for their reliability and operability. An alternative hot gas filtration technology is the moving granular bed filter. These systems are at a lower state of development than ceramic barrier filters, and their effectiveness as filters is still in question. Their apparent attributes, result from their much less severe mechanical design and materials constraints, and the potential for more reliable, failure-free particle removal operation. The standleg moving granular-bed filter (SMGBF) system, is a compact unit that uses cocurrent gas-pellet contacting in an arrangement that greatly simplifies and enhances the distribution of dirty, process gas to the moving bed and allows effective disengagement of clean gas from the moving bed. This paper describes the equipment and process test results.

Newby, R.A.; Yang, W.C.; Smeltzer, E.E.; Lippert, T.E.

1994-10-01T23:59:59.000Z

443

Task 3.13 - Hot-Gas Filter Testing  

Science Conference Proceedings (OSTI)

The objectives of the hot-gas cleanup (HGC) work on the transport reactor demonstration unit (TRDU) located at the Energy and Environmental Research Center (EERC) is to demonstrate acceptable performance of hot-gas filter elements in a pilot-scale system prior to long-term demonstration tests. The primary focus of the experimental effort in the 3-year project is the testing of hot-gas filter element performance (particulate collection efficiency, filter pressure differential, filter cleanability, and durability) as a fiction of temperature and filter face velocity during short-term operation (100-200 hours). The filter vessel is used in combination with the TRDU to evaluate the performance of selected hot-gas filter elements under gasification operating conditions. This work directly supports the power systems development facility (PSDF) utilizing the M.W. Kellogg transport reactor located at Wilsonville, Alabama (1) and, indirectly, the Foster Wheeler advanced pressurized fluid-bed combustor, also located at Wilsonville (2).

Michael L. Swanson

1998-01-01T23:59:59.000Z

444

Moving granular-bed filter development program. Topical report  

Science Conference Proceedings (OSTI)

Advanced, coal-based, power plants, such as IGCC and Advanced-PFBC, are currently nearing commercial demonstration. These power plant technologies require hot gas filtration as part of their gas cleaning trains. Ceramic barrier filters are the major filter candidates being developed for these hot gas cleaning applications. While ceramic barrier filters achieve high levels of particle removal, concerns exist for their reliability and operability in these applications. An alternative hot gas filtration technology is the moving granular bed filter. An advanced, moving granular bed filter has been conceived, and early development activities performed by the Westinghouse Electric Corporation, Science and Technology Center. This document reports on the Base Contract tasks performed to resolve the barrier technical issues for this technology. The concept, the Standleg Moving Granular Bed Filter (SMGBF) has a concurrent downward, gas and bed media flow configuration that results in simplified features and improved scaleup feasibility compared to alternative designs. Two modes of bed media operation were assessed in the program: once-through using pelletized power plant waste as bed media, and recycle of bed media via standleg and pneumatic transport techniques. Cold Model testing; high-temperature, high-pressure testing; and pelletization testing using advanced power plant wastes, have been conducted in the program. A commercial, economic assessment of the SMGBF technology was performed for IGCC and Advanced-PFBC applications. The evaluation shows that the barrier technical issues can be resolved, and that the technology is potentially competitive with ceramic barrier filters.

Newby, R.A.; Yang, W.C.; Smeltzer, E.E.; Lippert, T.E.

1994-04-01T23:59:59.000Z

445

Moving granular-bed filter development program topical report  

SciTech Connect

The Westinghouse Science Technology Center has proposed a novel moving granular-bed filter concept, the Standleg Moving Granular-Bed Filter (S-MGBF) system, that overcomes the inherent deficiencies of the current state-of-the-art moving granular-bed filter technology. The S-MGBF system combines two unique features that make it highly effective for use in advanced coal-fueled power plants. First, the S-MGBF system applies pelletization technology to generate filter pellets from the power plant solid waste materials, and uses these pellets as a once-through'' filtering media to eliminate the need for costly, complex, and large filter media recycling equipment. This pelletizing step also generates a more environmentally acceptable solid waste product and provides the potential to incorporate gas-phase contaminant sorbents into the filtering media. Secondly, the S-MGBF system passes these pellets and the flyash laden power plant gas through a highly compact S-MGBF that uses cocurrent gas-pellet contacting in an arrangement that greatly simplifies and enhances the distribution of dirty gas to the moving bed and the disengagement of clean gas from the moving bed.

Newby, R.A.; Dilmore, W.J.; Fellers, A.W.; Gasparovic, A.C.; Kittle, W.F.; Lippert, T.E.; Smeltzer, E.E.; Yang, W.C.

1991-10-17T23:59:59.000Z

446

Adjunctive Inferior Vena Cava Filter Placement for Acute Pulmonary Embolism  

SciTech Connect

Inferior vena cava (IVC) filters are sometimes placed as an adjunct to full anticoagulation in patients with significant pulmonary embolism (PE). We aimed to determine the prevalence of adjunctive IVC filter placement in individuals diagnosed with PE, as well as the effect of adjunctive filter placement on mortality in patients with right heart strain associated with PE. This was a retrospective study of patients with acute PE treated with full anticoagulation admitted to a single academic medical center. Information abstracted from patient charts included presence or absence of right heart strain and of deep-vein thrombosis, and whether or not an IVC filter was placed. The endpoint was in-hospital mortality. Over 2.75 years, we found that 248 patients were diagnosed with acute PE, with an in-hospital mortality rate of 4.4%. The prevalence of adjunctive IVC filter placement was 13.3% (33 of 248), and the prevalence of documented right heart strain was 27.0% (67 of 248). In-hospital mortality was 10.2% in the non-filter-treated group (5 of 49), whereas there were no deaths in the filter-treated group (0 of 18); however, the difference was not statistically significant (P = 0.37). Both the presence of deep-vein thrombosis and of right heart strain increased the likelihood that an adjunctive IVC filter was placed (P < 0.0001 and P < 0.001, respectively). At our institution, patients were treated with IVC filters in addition to anticoagulation in 13.3% of cases of acute PE. Prospective studies or large clinical registries should be conducted to clarify whether this practice improves outcomes.

Jha, V. M., E-mail: vjha@mfa.gwu.ed [George Washington University Medical Center, Division of Pulmonary and Critical Care Medicine, Department of Medicine (United States); Lee-Llacer, J. [George Washington University Medical Center, Department of Anesthesiology and Critical Care Medicine (United States); Williams, J.; Ubaissi, H.; Gutierrez, G. [George Washington University Medical Center, Division of Pulmonary and Critical Care Medicine, Department of Medicine (United States)

2010-08-15T23:59:59.000Z

447

Submitted by:  

E-Print Network (OSTI)

This report was prepared as an account of work sponsored by the California Air Resource Board. The statements and conclusions in this report are those of the contractor and not necessarily those of California Air Resources Board. The mention of commercial products, their source, or their use in connection with material reported herein is not to be construed as actual or implied endorsement of such products.

Mr. Bob Okamoto; Dr. Thomas; D. Durbin; Dr. J. Wayne Miller; Ms. S. Michelle Jiang

2010-01-01T23:59:59.000Z

448

Submitting Organization:  

E-Print Network (OSTI)

i ii The focus of this project is to develop a new large-volume application for selfcementing coal combustion products, namely in situ stabilization of gravel roads using self-cementing CCPs. Within the reduced scope of the project, the emphasis was placed on assessing the engineering properties of two recycled materials and a natural aggregate. Laboratory experiments were conducted in which a road surface gravel (RSG), a recycled pavement material (RPM), a natural crushed aggregate (Class 5 base) were tested to determine the California bearing ratio (CBR), resilient modulus (Mr), and unconfined compressive strength (UCS). The recycled materials were blended with two fly ash contents (10 and 15%) and three curing times (7, 28, and 56 d). A Class C fly ash with 0.7 % loss on ignition was used. Resilient modulus and unconfined compression strength tests were also conducted after 5 cycles of freezing and thawing to asses the impact of freeze-thaw cycling. Unstabilized RSG and RPM had CBRs greater than that of Class 5 base, but all

Wilfung Martono; Board Regents; University Of Wisconsin-madison

2008-01-01T23:59:59.000Z

449

Submitted to:  

E-Print Network (OSTI)

felt it would be easier for you to view the color photograph copy, in case this information was relevant to your review. We are asking you to send back the original after you copy it. You can keep the original for at least a month if necessary, and then return it. We are having a copy made for Philip Ramsey at JPG. Please be warned that the Agency has not completed it's review of the document. We have not included the Executive Summary Chapter 1, or Chapter 5 the Recommendations portion, because these are enforcement sensitive at this time. We would be happy to discuss with you or Phil what are recomiendations might be on some of the areas. We are currently working on the review of the USATHEMA Workplan, and will send comments to Phil when they are organized. We also will send you a copy of Region V's Quality Assurance Protocols that must be met for compliance with a RCRA Facility Investigation. I hope the information will be useful to you. If you have any questions regarding this matter, please contact me at (312) 886-6146. or Hak Cho at

Abraham Chen Ph. D; King Ave; Carol Ann Wi Tt-smi Th; Phil Ramsey Jpg

1992-01-01T23:59:59.000Z

450

Submitted by  

E-Print Network (OSTI)

This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. Final Report DE-FC26-06NT42724 The overall objective of the present work was to develop technologies to reduce freshwater consumption in a cooling tower of coal-based power plant so that one could significantly reduce the need of make-up water. The specific goal was to develop a scale

Young I Cho; Er A. Fridman

2009-01-01T23:59:59.000Z

451

Submitting Organizations:  

E-Print Network (OSTI)

This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the The objective of the project is to apply a unique ice thermal storage (ITS) technology to cooling the intake air to gas turbines used for power generation. In Phase I, the work includes theoretical analysis, computer simulation, engineering design and cost evaluation of this novel ITS technology. The study includes two typical gas turbines (an industrial and an aeroderivative type gas

Guy Weismantel; Doe Award; No. De-fg-nt

2004-01-01T23:59:59.000Z

452

SUBMITTED BY  

E-Print Network (OSTI)

i TABLE OF CONTENTS Disclaimer.iv Acknowledgement..v Table of abbreviations.vi Table of cases..vii

Dr. Sanjay; Kumar Pandey; Meghna Chandra

2013-01-01T23:59:59.000Z

453

Submitting Comments  

Science Conference Proceedings (OSTI)

... Mr. Public pulls up a copy of the cross sectional view of the battery. He explans the drawbacks of thinner partitions with regard to battery life. ...

454

Electrically heated particulate filter with zoned exhaust flow control  

SciTech Connect

A system includes a particulate matter (PM) filter that includes X zones. An electrical heater includes Y heater segments that are associated with respective ones of the X zones. The electrical heater is arranged upstream from and proximate with the PM filter. A valve assembly includes Z sections that are associated with respective ones of the X zones. A control module adjusts flow through each of the Z sections during regeneration of the PM filter via control of the valve assembly. X, Y and Z are integers.

Gonze, Eugene V [Pinckney, MI

2012-06-26T23:59:59.000Z

455

85-GAL DRUM AND NUCFIL-007LS FILTERS  

DOE Green Energy (OSTI)

{sm_bullet} 55-gallon drums were overpacked into 85-gallon drums {sm_bullet} ANucFiI-007LS long-stem filter was installed- NucFiI certified the use of NucFiI-007LS filters in 8S-gallon drums as DOT 7AType A - Wood wedges were used during the tests to center and . stabilize the inner 55-gallon drums {sm_bullet} During inspection, afew filters were found to be loose, canted, and/or with RTV seals broken - No contamination or loss of container integrity {sm_bullet} Discovered in November 2008 U.

JB WOODBURY

2009-06-30T23:59:59.000Z

456

An Innovative Method for Dynamic Characterization of Fan Filter Unit Operation.  

E-Print Network (OSTI)

Laboratory Methods of Testing Fans for Rating. ASHRAE. 1987.Efficient Filtration: Fan filter units. Final Report,Energy Performance of Fan Filter Units, Version 1.3.

Xu, Tengfang

2006-01-01T23:59:59.000Z

457

Low-complexity adaptive filtering algorithms based on the minimum L [infinity]-norm method.  

E-Print Network (OSTI)

??The complexity of an adaptive filtering algorithm is proportional to the tap length of the filter and hence, may become computationally prohibitive for applications requiring (more)

Tandon, Abhishek

2004-01-01T23:59:59.000Z

458

When do I need to submit a White Paper, Letter Of Intent or pre-Proposal through DSR?  

E-Print Network (OSTI)

When do I need to submit a White Paper, Letter Of Intent or pre-Proposal through DSR? · Sponsor requires only a white paper/letter of intent. · No budget is being submitted. · No authorized signature. · Sponsor requires white paper/letter of intent be signed by an Authorized Official. · No budget is being

Jawitz, James W.

459

Motor Pool Guidelines for Geosciences A completed Motor Pool Request form must be submitted to Denise for  

E-Print Network (OSTI)

Motor Pool Guidelines for Geosciences · A completed Motor Pool Request form must be submitted on the Geosciences website under the forms link. http://www.geo.arizona.edu/pdf/motor_pool_request.pdf · If the trip be submitted with the Motor Pool Request. · A list of passengers and drivers is for all motor pool travel (this

Holliday, Vance T.

460

Microhydropower Conveyance and Filter Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conveyance and Filter Basics Conveyance and Filter Basics Microhydropower Conveyance and Filter Basics August 16, 2013 - 3:53pm Addthis Before water enters the turbine or waterwheel of a microhydropower system, it is funneled through a series of components that control its flow and filter out debris. These components include the headrace, forebay, and water conveyance (or channel, pipeline, or penstock). The headrace is a waterway that runs parallel to the water source. A headrace is sometimes necessary for hydropower systems when insufficient head, or vertical drop, is provided and is usually constructed of cement or masonry. The headrace leads to the forebay, which also is made of concrete or masonry. It functions as a settling pond for large debris that would otherwise flow into the system and damage the turbine.

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Sequential State and Variance Estimation within the Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

Kalman filter methods for real-time assimilation of observations and dynamical systems typically assume knowledge of the system parameters. However, relatively little work has been done on extending state estimation procedures to include ...

Jonathan R. Stroud; Thomas Bengtsson

2007-09-01T23:59:59.000Z

462

State Estimation Using a Reduced-Order Kalman Filter  

Science Conference Proceedings (OSTI)

Minimizing forecast error requires accurately specifying the initial state from which the forecast is made by optimally using available observing resources to obtain the most accurate possible analysis. The Kalman filter accomplishes this for a ...

Brian F. Farrell; Petros J. Ioannou

2001-12-01T23:59:59.000Z

463

A Pre-filter Enabling Fast Frontal Face Detection  

Science Conference Proceedings (OSTI)

We present a novel pre-filtering technique that identifies probable frontal illuminated face regions in colour images regardless of translation, orientation, and scale. The face candidate regions are normalised and provide the basis for face verification ...

Stephen C. Y. Chan; Paul H. Lewis

1999-06-01T23:59:59.000Z

464

The Diffusion Kernel Filter Applied to Lagrangian Data Assimilation  

Science Conference Proceedings (OSTI)

The diffusion kernel filter is a sequential particle-method approach to data assimilation of time series data and evolutionary models. The method is applicable to nonlinear/non-Gaussian problems. Within branches of prediction it parameterizes ...

Paul Krause; Juan M. Restrepo

2009-12-01T23:59:59.000Z

465

Filtering Integration Schemes Based on the Laplace and Z Transforms  

Science Conference Proceedings (OSTI)

A filtering integration scheme based on a modification of the inversion integral for the Laplace transform (LT) is developed and implemented in a barotropic limited-area model. The LT scheme is compared to a conventional scheme and shown to ...

Peter Lynch

1991-03-01T23:59:59.000Z

466

A Hierarchy of Nonlinear Filtered ModelsNumerical Solutions  

Science Conference Proceedings (OSTI)

Five filtered models, including two that are intermediate between the balanced and the primitive equations, are studied using actual weather data. The iterative method of solution works well in most cases. The two more general models are solved ...

Trond Iversen; Thor Erik Nordeng

1984-10-01T23:59:59.000Z

467

Operational Validation of the MOPITT Instrument Optical Filters  

Science Conference Proceedings (OSTI)

Optical bandpass filters in the Measurements of Pollution in the Troposphere (MOPITT) satellite remote sensing instrument selectivity limit the throughput radiance to absorptive spectral bands associated with the satellite-observed trace gases CO ...

M. N. Deeter; G. L. Francis; D. P. Edwards; J. C. Gille; E. McKernan; James R. Drummond

2002-11-01T23:59:59.000Z

468

A Hybrid Ensemble Kalman Filter3D Variational Analysis Scheme  

Science Conference Proceedings (OSTI)

A hybrid ensemble Kalman filterthree-dimensional variational (3DVAR) analysis scheme is demonstrated using a quasigeostrophic model under perfect-model assumptions. Four networks with differing observational densities are tested, including one ...

Thomas M. Hamill; Chris Snyder

2000-08-01T23:59:59.000Z

469

Oil Bypass Filter Technology Evaluation - Tenth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INLEXT-05-00381 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Tenth Quarterly Report January-March 2005 TECHNICAL...

470

Oil Bypass Filter Technology Evaluation - Third Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-03-00974 U.S. Department of Energy FreedomCAR & Vehicle Technologies Oil Bypass Filter Technology Evaluation Third Quarterly Report April-June 2003 Larry Zirker James...

471

Oil Bypass Filter Technology Evaluation - Ninth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INLEXT-05-00040 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Ninth Quarterly Report October-December 2004 TECHNICAL...

472

VECTOR MEDIAN-RATIONALHYBRID FILTERS FOR MULTICHANNELIMAGE Lazhar Khriji  

E-Print Network (OSTI)

thevectorrationaloperator(VRF)(Theoutputisthe result of vector rational operation taking into account three sub/outputrelation, and hence the name "vectorrational filters" (VRF's)[3]. There are several advantage to the use

Gabbouj, Moncef

473

Improved Collaborative Filtering Aviv Nisgav and Boaz Patt-Shamir  

E-Print Network (OSTI)

resilience in the presence of many users with esoteric taste. 1 Introduction The collaborative filtering (or is that reconstructing "esoteric" preferences (preferences that are held by only few users) may require considerably more

Lynch, Nancy

474

An Improved Filter Technique for Ice Nucleus Measurements  

Science Conference Proceedings (OSTI)

No satisfactory standard field method has been established for the measurement of ice nucleus concentrations, although the filter technique is a promising candidate if the tendency for ice nucleus concentrations to decrease as the sample volume ...

Chi-Fan Shih; Takeshi Ohtake

1985-09-01T23:59:59.000Z

475

Observation Quality Control with a Robust Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

Current ensemble-based Kalman filter (EnKF) algorithms are not robust to gross observation errors caused by technical or human errors during the data collection process. In this paper, the authors consider two types of gross observational errors, ...

Soojin Roh; Marc G. Genton; Mikyoung Jun; Istvan Szunyogh; Ibrahim Hoteit

2013-12-01T23:59:59.000Z

476

Kalman Filter and Analog Schemes to Postprocess Numerical Weather Predictions  

Science Conference Proceedings (OSTI)

Two new postprocessing methods are proposed to reduce numerical weather predictions systematic and random errors. The first method consists of running a postprocessing algorithm inspired by the Kalman filter (KF) through an ordered set of analog ...

Luca Delle Monache; Thomas Nipen; Yubao Liu; Gregory Roux; Roland Stull

2011-11-01T23:59:59.000Z

477

Vertical Covariance Localization for Satellite Radiances in Ensemble Kalman Filters  

Science Conference Proceedings (OSTI)

A widely used observation space covariance localization method is shown to adversely affect satellite radiance assimilation in ensemble Kalman filters (EnKFs) when compared to model space covariance localization. The two principal problems are ...

William F. Campbell; Craig H. Bishop; Daniel Hodyss

2010-01-01T23:59:59.000Z

478

Event dissemination via group-aware stream filtering  

Science Conference Proceedings (OSTI)

We consider a distributed system that disseminates high-volume event streams to many simultaneous monitoring applications over a low-bandwidth network. For bandwidth efficiency, we propose a group-aware stream filtering approach, used together with multicasting, ...

Ming Li; David Kotz

2008-07-01T23:59:59.000Z

479

The trilateral filter for high contrast images and meshes  

Science Conference Proceedings (OSTI)

We present a new, single-pass nonlinear filter for edge-preserving smoothing and visual detail removal for N dimensional signals in computer graphics, image processing and computer vision applications. Built from two modified forms of Tomasi and ...

Prasun Choudhury; Jack Tumblin

2005-07-01T23:59:59.000Z

480

Higher Resolution in an Operational Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

Recently, the computing facilities available to the Meteorological Service of Canada were significantly upgraded. This provided an opportunity to improve the resolution of the global Ensemble Kalman Filter (EnKF) and the medium-range Global ...

P. L. Houtekamer; Xingxiu Deng; Herschel L. Mitchell; Seung-Jong Baek; Normand Gagnon

Note: This page contains sample records for the topic "filters submitted wang" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Boundary Conditions for Limited-Area Ensemble Kalman Filters  

Science Conference Proceedings (OSTI)

One aspect of implementing a limited-area ensemble Kalman filter (EnKF) involves the specification of a suitable ensemble of lateral boundary conditions. Two classes of methods to populate a boundary condition ensemble are proposed. In the first ...

Ryan D. Torn; Gregory J. Hakim; Chris Snyder

2006-09-01T23:59:59.000Z

482

Empirical Localization of Observation Impact in Ensemble Kalman Filters  

Science Conference Proceedings (OSTI)

Localization is a method for reducing the impact of sampling errors in ensemble Kalman filters. Here, the regression coefficient, or gain, relating ensemble increments for observed quantity y to increments for state variable x is multiplied by a ...

Jeffrey Anderson; Lili Lei

483

Ground Clutter Filtering Dual-Polarized, Staggered PRT Sequences  

Science Conference Proceedings (OSTI)

A procedure to filter the ground clutter from a dual-polarized, staggered pulse repetition time (PRT) sequence and recover the complex spectral coefficients of the weather signal is presented. While magnitude spectra are sufficient for estimation ...

M. Sachidananda; Dusan S. Zrnic

2006-08-01T23:59:59.000Z

484

Error Covariance Modeling in the GMAO Ocean Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

In practical applications of the ensemble Kalman filter (EnKF) for ocean data assimilation, the computational burden and memory limitations usually require a trade-off between ensemble size and model resolution. This is certainly true for the ...

Christian L. Keppenne; Michele M. Rienecker; Jossy P. Jacob; Robin Kovach

2008-08-01T23:59:59.000Z

485

Assimilating Vortex Position with an Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

Observations of hurricane position, which in practice might be available from satellite or radar imagery, can be easily assimilated with an ensemble Kalman filter (EnKF) given an operator that computes the position of the vortex in the background ...

Yongsheng Chen; Chris Snyder

2007-05-01T23:59:59.000Z

486

Observation Quality Control with a Robust Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

Current ensemble-based Kalman filter (EnKF) algorithms are not robust to gross observation errors caused by technical or human errors during the data collection process. In this paper, we consider two types of gross observational errors, additive ...

Soojin Roh; Marc G. Genton; Mikyoung Jun; Istvan Szunyogh; Ibrahim Hoteit

487

Low-Pass Filters to Suppress Inertial and Tidal Frequencies  

Science Conference Proceedings (OSTI)

A systematic way is given to design digital filters which allow clear separation of signals with periods of a few days from noise of higher frequency, particularly tidal and inertial. Several examples are given which pass little high-frequency ...

Rory O. R. Y. Thompson

1983-06-01T23:59:59.000Z

488

Best Practice for Energy Efficient Cleanrooms: Fan-Filter Units  

E-Print Network (OSTI)

control F iltra ti on ? Fan Efficiency ? Right Sizing ?Energy Performance of Fan-Filte r Units, Version 1.3 (2005),RP36.1 (Draft). Testing Fan-Filter Units. Draft Recommended

Xu, Tengfang

2005-01-01T23:59:59.000Z

489

Developing a Standard Test Method for Characterizing Fan-filter...  

NLE Websites -- All DOE Office Websites (Extended Search)

Developing a Standard Test Method for Characterizing Fan-filter Units Used in Industries Speaker(s): Tim Xu Date: July 21, 2008 - 12:00pm Location: 90-3122 Seminar HostPoint of...

490

An Ensemble Adjustment Kalman Filter for Data Assimilation  

Science Conference Proceedings (OSTI)

A theory for estimating the probability distribution of the state of a model given a set of observations exists. This nonlinear filtering theory unifies the data assimilation and ensemble generation problem that have been key foci of prediction ...

Jeffrey L. Anderson

2001-12-01T23:59:59.000Z

491

Chip-Scale Quadrupole Mass Filters for Portable Mass Spectrometry  

E-Print Network (OSTI)

We report the design, fabrication, and characterization of a new class of chip-scale quadrupole mass filter (QMF). The devices are completely batch fabricated using a wafer-scale process that integrates the quadrupole ...

Cheung, Kerry

492

Particle filtering with Lagrangian data in a point vortex model  

E-Print Network (OSTI)

Particle filtering is a technique used for state estimation from noisy measurements. In fluid dynamics, a popular problem called Lagrangian data assimilation (LaDA) uses Lagrangian measurements in the form of tracer positions ...

Mitra, Subhadeep

2012-01-01T23:59:59.000Z

493

Factor estimation using MCMC-based Kalman filter methods  

Science Conference Proceedings (OSTI)

An exact MCMC-based solution for the Kalman filter with Markov switching and GARCH components is proposed. To motivate the solution, an international equity market model incorporating common Markovian regimes and GARCH residuals in a persistent factor ...

Sarantis Tsiaplias

2008-12-01T23:59:59.000Z

494

Kalman filtering of IMU sensor for robot balance control  

E-Print Network (OSTI)

This study explores the use of Kalman filtering of measurements from an inertial measurement unit (IMU) to provide information on the orientation of a robot for balance control. A test bed was created to characterize the ...

Angelosanto, Gina (Gina C.)

2008-01-01T23:59:59.000Z

495

Fluid mechanics of membrane-coated ceramic filters  

SciTech Connect

Analytical models are formulated for evaluating the fluid mechanics of membrane-coated, dead-end ceramic filters. The models are applicable to forward flow as in the filtration mode and reverse flow as in the back-pulse cleaning mode. General criteria are derived to size the filter passages from considerations of Darcy pressure drop, friction pressure drop, and the dynamic head. These criteria together with Reynolds numbers are shown to provide measures of nonuniformities in face velocity and pressure that develop in the filter passages for atmospheric and high-pressure applications. A methodology is presented for optimizing the venturi geometry from the standpoint of minimizing pulse gas usage and controlling the thermal load imposed on the filter assembly.

Ahluwalia, R.K.; Geyer, H.K. [Argonne National Lab., IL (United States). Technology Development Div.

1996-07-01T23:59:59.000Z

496

2010 EPRI-Southern Company Services Fabric Filter Workshop Proceedings  

Science Conference Proceedings (OSTI)

The use of fabric filters (also called baghouses) on coal-fired boilers in power plants has increased significantly in the past several years due to increasingly stringent particulate matter emissions limits. These limits have become even more challenging in light of the proposed maximum achievable control technology (MACT) ruling for air toxics by the U.S. Environmental Protection Agency on March 16, 2011. The proposed MACT ruling will require control of both filterable and condensable particulate matte...

2011-04-28T23:59:59.000Z

497

FIESTA II a software tool for electronic filter design  

E-Print Network (OSTI)

This thesis describes a software program, FIESTA II, for the design of electronic filters. It is an expanded version of the FIESTA program written at Texas A&M University in 1989. It is a complete tool for both approximation and synthesis of many types of analog filters. One goal of this research was to design a generalized program for filter design that would be easy to use, powerful, and most of all, expandable. Most filter design programs are very limited in their scope, only performing basic approximations and supporting the most conventional of filter implementations. Plus, they offer virtually no way for the user to expand the program to perform more sophisticated filter design. Additionally, it is hoped that FIESTA II, with its special modular and generic design, will serve as a basis for future work in automatic analog circuit synthesis. The research began with the porting of the original FIESTA from Apollo workstation to generic ANSI-C/UNIX format. Then, the code was reorganized and an industry-standard X-Windows graphical user interface was added. Next, several new and advanced features were added, such as quasi-elliptic magnitude approximation, optimized s-z transformations, leapfrog topology, additional implementations (passive RLC, active-RC, switched-capacitor, MOSFET-C), and user-defined synthesis structures. Experimental results, some of which are included here, prove that FIESTA II is an effective filter design tool. It contains many features which are unique to programs for filter design. In conclusion, FIESTA 11 provides a convincing case for the feasibility of automatic design of analog circuits.

Kenzle, Wilfred Vance