  1. High Efficiency Room Air Conditioner

    SciTech Connect (OSTI)

    Bansal, Pradeep

    2015-01-01

    This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.

  2. Building Pressure Control in VAV System with Relief Air Fan 

    E-Print Network [OSTI]

    Pang, X.; Liu, M.; Zheng, B.

    2005-01-01

    Building Pressure Control in VAV Systems with Relief Air Fan Xiufeng Pang, Mingsheng Liu, PhD, P.E., Bin Zheng University of Nebraska, Lincoln—ESL 1110 So. 67 th St, Omaha, NE, 68182 Abstract Building pressure control is critical... to energy conservation and indoor air quality by preventing excessive infiltration or exfiltration. In the supply and the return/relief fan Air Handling Unit (AHU) system, better space pressurization can be achieved when return/relief fan operates...

  3. Model-Based Commissioning for Filters in Room Air Conditioners 

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Kitagawa, H.; Matsumoto, K.; Goto, K.

    2004-01-01

    This paper proposes a model that can estimate filter resistance. Two sorts of value are used as inputs to estimate filter resistance. One is the power consumed by the fan in the indoor unit and the other is the thermal performance. For the room air...

  4. Choosing the right boiler air fans at Weston 4

    SciTech Connect (OSTI)

    Spring, N.

    2009-04-15

    When it came to choosing the three 'big' boiler air fans - forced draft, induced draft and primary air, the decision revolved around efficiency. The decision making process for fan selection for the Western 4 supercritical coal-fired plant is described in this article. 3 photos.

  5. Room Air Conditioners | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Room Air Conditioners Room Air Conditioners July 1, 2012 - 5:35pm Addthis A room air conditioner is one solution to cooling part of a house. | Photo courtesy of iStockphoto...

  6. Computer Room Fresh Air Cooling 

    E-Print Network [OSTI]

    Wenger, J. D.

    1985-01-01

    payback and must not compromise re1 iabil i ty. POSS IB ILITIES FOR REDUCING ENERGY CONSUMPTION To offer reduced energy consumption during periods of 1 ow wbi ent temperature, computer room air handlers can be fitted with economizer coils to precool... the air using fluid from a sensible, or for lower fluid temperatures, an evaporative heat rejector (Figure 1). As the ambient temperature rises close to the required supply air temperature, operation of the economizer coil is limited...

  7. Control of Computer Room Air Conditioning using IT Equipment Sensors

    E-Print Network [OSTI]

    Bell, Geoffrey C.

    2010-01-01

    Control of Computer Room Air Conditioning using IT EquipmentControl of Computer Room Air Conditioning using IT equipmentcontrol computer room air conditioning. The data provided

  8. Supply Fan Control for Constant Air Volume Air Handling Units 

    E-Print Network [OSTI]

    Cho, Y.; Wang, G.; Liu, M.

    2007-01-01

    Since terminal boxes do not have a modulation damper in constant volume (CV) air handling unit (AHU) systems, zone reheat coils have to be modulated to maintain the space temperature with constant supply airflow. This conventional control sequence...

  9. Room air monitor for radioactive aerosols

    DOE Patents [OSTI]

    Balmer, David K. (Broomfield, CO); Tyree, William H. (Boulder, CO)

    1989-04-11

    A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-pre The U.S. Government has rights in this invention pursuant to Contract No. DE-AC04-76DP03533 between the Department of Energy and Rockwell International Corporation.

  10. Room air monitor for radioactive aerosols

    DOE Patents [OSTI]

    Balmer, D.K.; Tyree, W.H.

    1987-03-23

    A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-preamplifier combination. 2 figs.

  11. Room Air Conditioners | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Financing Tool FitsProject DevelopsforReportingResourcesDepartmentDepartment ofRoom Air

  12. Development of models for series and parallel fan variable air volume terminal units 

    E-Print Network [OSTI]

    Furr, James C., Jr

    2007-09-17

    Empirical models of airflow output and power consumption were developed for series and parallel fan powered variable air volume terminal units at typical design pressure conditions. A testing procedure and experimental setup were developed to test...

  13. Variable Speed Fan Retrofits for Computer Room Air Conditioners...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    NSIDC Data Center: Energy Reduction Strategies Energy Efficiency Opportunities in Federal High Performance Computing Data Centers Wireless Sensors Improve Data Center Efficiency...

  14. Variable Speed Fan Retrofits for Computer Room Air Conditioners

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on DeliciousMathematics And Statistics » USAJobs Search USAJobs SearchWater-SavingofCode |DepartmentVampire

  15. Variable Speed Fan Retrofits for Computer Room Air Conditioners |

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann Jackson About1996HowFOAShowing YouNeedofDepartmentVOICES of Experience955

  16. Performance Analysis of Dual-Fan, Dual-Duct Constant Volume Air-Handling Units 

    E-Print Network [OSTI]

    Joo, I. S.; Liu, M.

    2001-01-01

    Dual-fan, dual-duct air-handling units introduce outside air directly into the cooling duct and use two variable speed devices to independently maintain the static pressure of the hot and the cold air ducts. Analytical models have been developed...

  17. New Whole-House Solutions Case Study: Evaluating Through-Wall Air Transfer Fans, Pittsburgh, Pennsylvania

    SciTech Connect (OSTI)

    2014-10-01

    In this project, Building America team IBACOS performed field testing in a new construction unoccupied test house in Pittsburgh, Pennsylvania, to evaluate heating, ventilating, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. The team evaluated a market-available through-wall air transfer fan system that provides air to the bedrooms.The relative ability of this system was considered with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability.

  18. Prediction of Room Air Diffusion for Reduced Diffuser Flow Rates 

    E-Print Network [OSTI]

    Gangisetti, Kavita

    2011-02-22

    are compared against the measured data. Other important parameters such as diffuser jet inlet angle and radiation effect are also considered on the benchmark case to validate the results and to recommend the best fit parameters for room air simulations...

  19. Building America Case Study: Evaluating Through-Wall Air Transfer Fans, Pittsburgh, Pennsylvania (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-10-01

    In this project, Building America team IBACOS performed field testing in a new construction unoccupied test house in Pittsburgh, Pennsylvania to evaluate heating, ventilating, and air conditioning (HVAC) distribution systems during heating, cooling, and midseason conditions. Four air-based HVAC distribution systems were assessed:-a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, a system with transfer fans to the bedrooms, and a system with no ductwork to the bedrooms. The relative ability of each system was considered with respect to relevant Air Conditioning Contractors of America and ASHRAE standards for house temperature uniformity and stability, respectively.

  20. Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis 

    E-Print Network [OSTI]

    Kimla, John

    2010-07-14

    The potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has focused on the creation of reset strategies depending on specific ...

  1. Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power and Thermal Energy - Part 2: Case Demonstration for a Typical Climate System 

    E-Print Network [OSTI]

    Liu, M.; Zheng, K.; Wu, L.; Wang, Z.; Johnson, C.

    2007-01-01

    In Part 1 of this paper, the theoretical models, integrating the fan airflow, fan head, air leakage factors, are developed to analyze the impacts of the static pressure reset on both pressure dependent and pressure independent terminal boxes...

  2. Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power and Thermal Energy - Part I: Theoretical Model and Simulation 

    E-Print Network [OSTI]

    Liu, M.; Feng, J.; Wang, Z.; Wu, L.; Zheng, K.; Pang, W.

    2007-01-01

    pressure reset has also applicable advantages over the existing constant static pressure set point and two typical reset methods. This paper present the theoretical models to express the impacts of static pressure reset on fan airflow, fan head, air leakage...

  3. Inferring Air Pollution by Sniffing Social Media Shike Mei, Han Li, Jing Fan, Xiaojin Zhu and Charles R. Dyer

    E-Print Network [OSTI]

    Dyer, Charles R.

    Inferring Air Pollution by Sniffing Social Media Shike Mei, Han Li, Jing Fan, Xiaojin Zhu issue of air pollution in China and elsewhere in the world is to monitor it. While more physical prediction performance of our approach. I. INTRODUCTION Air pollution is a significant issue in China

  4. Inferring Air Pollution by Sniffing Social Media Shike Mei, Han Li, Jing Fan, Xiaojin Zhu and Charles R. Dyer

    E-Print Network [OSTI]

    Zhu, Xiaojin "Jerry"

    Inferring Air Pollution by Sniffing Social Media Shike Mei, Han Li, Jing Fan, Xiaojin Zhu issue of air pollution in China and elsewhere in the world is to monitor it. While more physical monitoring stations are built, current coverage is limited to large cities with most other places under

  5. Energy performance of air distribution systems part II: room air stratification full scale testing

    E-Print Network [OSTI]

    Webster, Tom; Lukaschek, Wolfgang; Dickeroff, Darryl; Bauman, Fred

    2007-01-01

    the DDR to exceed its rated airflow. Energy Performance ofEnergy Performance of UFAD Systems Part II: Room Air Stratification Full Scale Testing Airflow cfm/sf m³/(sm²) DDR

  6. Distribution and Room Air Mixing Risks to Retrofitted Homes

    SciTech Connect (OSTI)

    Burdick, A.

    2014-12-01

    ?Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

  7. Impact of Environmental Factors on Efficacy of Upper-Room Air

    E-Print Network [OSTI]

    Pace, Norman

    Impact of Environmental Factors on Efficacy of Upper-Room Air Ultraviolet Germicidal Irradiation of an upper-room air ultravioletgermicidalirradiation(UVGI)system for inactivating airborne bacteria, which was skewed to one side compared to being evenly dispersed, and the room air temperature was stratified from

  8. Covered Product Category: Room Air Conditioners | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum Based| Department of Energy Whole-Home Gas Tankless Water HeatersRoom Air

  9. List of Room Air Conditioners Incentives | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIXsource History ViewInformationWindsCompressedList of RefuelingRoom Air Conditioners

  10. ISSUANCE 2015-06-09: Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information

    Office of Energy Efficiency and Renewable Energy (EERE)

    Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information

  11. Smart Fan Modules And System

    DOE Patents [OSTI]

    Cipolla, Thomas M. (Katonah, NY); Kaufman, Richard I. (Somers, NY); Mok, Lawrence S. (Brewster, NY)

    2003-07-15

    A fan module including: two or more individual fans, each fan having an air movement means and a motor engaged with the air movement means for accelerating air entering each of the two or more individual fans; a temperature sensor for sensing a temperature associated with the two or more fans and for outputting a first signal corresponding to the temperature; rotational speed sensor for outputting a second signal corresponding to a rotational speed of each of the two or more fans; and a processor for receiving the first and second signals and controlling the two or more individual fans based on the first and second signals. A fan module including: two or more individual fans, each fan having an air movement means and a motor engaged with the air movement means for accelerating air entering each of the two or more individual fans; a temperature sensor for sensing a temperature associated with the two or more fans and for outputting a first signal corresponding to the temperature; rotational speed sensor for outputting a second signal corresponding to a rotational speed of each of the two or more fans; and a processor for receiving the first and second signals and controlling the two or more individual fans based on the first and second signals.

  12. Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals 

    E-Print Network [OSTI]

    Wang, F.; Yoshida, H.; Matsumoto, K.

    2006-01-01

    time can be known so that its energy consumption can be estimated accurately. In order to verify the simulation accuracy, an actual room equipped with a gas-engine heat pump (GHP) air-conditioning system is studied by both simulation and measurement...

  13. NUMERICAL SIMULATIONS OF AIR FLOW AND HEAT TRANSFER VIA PDES Fei Cao, Luz Angelica Caudillo-Mata, Natalia Iwanski, Yong Li, Kamran Sadiq,

    E-Print Network [OSTI]

    by the air conditioning units (ACUs) with large scale fans into the plenum thereby pressurizing it of the air conditioning units; these are meant to extract (hot) air out of the room. Thus, equipment like

  14. Laser Sheet Light Flow Visualization For Evaluating Room Air Flows From

    E-Print Network [OSTI]

    LBNL-56483 Laser Sheet Light Flow Visualization For Evaluating Room Air Flows From Registers Iain S using a Planar Laser-Induced Fluorescence (PLIF) measurement technique. Water marked with fluorescent

  15. Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-02-01

    Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems - a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms - were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

  16. Analysis of Energy Saving in a Clean Room Air-conditioning System 

    E-Print Network [OSTI]

    Liu, S.; Liu, J.; Pei, J.; Wang, M.

    2006-01-01

    To address the issue of the substantial energy cost and operating cost of an all-return air system for a clean room, we changed the former system to a 2nd return air system. With the newest building energy simulation program, Energy Plus, we...

  17. Existing Whole-House Solutions Case Study: Passive Room-to-Room Air Transfer, Fresno, California

    SciTech Connect (OSTI)

    D. Stecher and A. Poershke

    2014-02-01

    In this project, IBACOS, a U.S. Department of Energy Building America team, assessed a strategy for providing conditioned air to bedrooms when the bedroom doors are closed and measured potential thermal discomfort that occupants may experience when this strategy is used. Builders can use this information to discuss space conditioning options for low-load houses with their clients to determine acceptable comfort levels for occupants in these cost-optimized, energy-efficient houses.

  18. Covered Product Category: Room Air Conditioners | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p aDepartmentEnergyEvery Thanksgiving, we hearfreezers, aroom air

  19. Ceiling Fan and Ceiling Fan Light Kit use in the U.S. Results of a Survey on Amazon Mechanical Turk

    E-Print Network [OSTI]

    Kantner, Colleen L.S.

    2013-01-01

    air conditioning .31   3.7   Impact of ceiling fans on air conditioningowners increased the air conditioning thermostat temperature

  20. Sniffing by a silkworm moth: Wing fanning enhances air penetration through and pheromone interception by antennae

    E-Print Network [OSTI]

    Loudon, Catherine; Koehl, M. A. R.

    2000-10-01

    Many organisms increase the air or water flow adjacent to olfactory surfaces when exposed to appropriate chemical stimuli; such 'sniffing' samples fluid from a specific region and can increase the rate of interception of odorant molecules. We used...

  1. Development of In-Situ Fan Curve Measurement with One Airflow Measurement 

    E-Print Network [OSTI]

    Liu, G.; Joo, I. S.; Song, L.; Liu, M.

    2003-01-01

    Fan airflow is the key parameter for air volume tracking control in variable air volume systems. One of the airflow measurement methods is to determine airflow using the fan speed, fan head, and fan curve. Both fan speed and fan head can be measured...

  2. A STUDY OF COMPUTATIONAL FLUID DYNAMICS APPLIED TO ROOM AIR FLOW

    E-Print Network [OSTI]

    for supplying me a copy of his three-dimensional, laminar, constant density fluid flow computer program, whichi A STUDY OF COMPUTATIONAL FLUID DYNAMICS APPLIED TO ROOM AIR FLOW By JAMES W. WEATHERS Bachelor of the requirements for the Degree of MASTER OF SCIENCE May, 1992 #12;ii A STUDY OF COMPUTATIONAL FLUID DYNAMICS

  3. ISSUANCE 2015-07-17: Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information, Extension of the Public Comment Period

    Office of Energy Efficiency and Renewable Energy (EERE)

    Energy Conservation Program: Energy Conservation Standards for Room Air Conditioners; Request for Information, Extension of the Public Comment Period

  4. Improving Best Air Conditioner Efficiency by 20-30% through a High Efficiency Fan and Diffuser Stage Coupled with an Evaporative Condenser Pre-Cooler

    SciTech Connect (OSTI)

    Parker, Danny S; Sherwin, John R; Raustad, Richard

    2014-04-10

    The Florida Solar Energy Center (FSEC) conducted a research project to improve the best residential air conditioner condenser technology currently available on the market by retrofitting a commercially-available unit with both a high efficiency fan system and an evaporative pre-cooler. The objective was to integrate these two concepts to achieve an ultra-efficient residential air conditioner design. The project produced a working prototype that was 30% more efficient compared to the best currently-available technologies; the peak the energy efficiency ratio (EER) was improved by 41%. Efficiency at the Air-Conditioning and Refrigeration Institute (ARI) standard B-condition which is used to estimate seasonal energy efficiency ratio (SEER), was raised from a nominal 21 Btu/Wh to 32 Btu/Wh.

  5. A FULL SCALE ROOM FOR THE EXPERIMENTAL STUDY OF INTERIOR BUILDING CONVECTIVE HEAT TRANSFER

    E-Print Network [OSTI]

    heated panel system mounted on the inside of the cells. ASHRAE Standard 51 was employed for volumetric air flow measurement. A water source heat pump provided chilled water to a fan-coil unit which in turn on volumetric air flow measurement and an overall room heat balance. Analysis was directed at results from

  6. Indoor Chemical Exposures: Humans' Non-respiratory Interactions with Room Air

    ScienceCinema (OSTI)

    Charles Weschler

    2010-09-01

    March 18, 2010 Berkeley Lab Environmental Energy Technology Division distinguished lecture: The marked difference in pollutant concentrations between an occupied and un-occupied room are only partially explained by human bio-effluents. Humans alter levels of ozone and related oxidants such as nitrate and hydroxyl radicals in the rooms they inhabit; in effect, they change the oxidative capacity of room air. Ozone-initiated reactions on exposed skin, hair and clothing generate products, including potentially irritating chemicals whose concentrations are much higher in the occupant's breathing zone than in the core of the room. Charles J. Weschler is a Professor at the School of Public Health, the Department of Environmental and Occupational Medicine and the Environmental and Occupational Health Sciences Institute (EOHSI) at the University of Medicine and Dentistry of New Jersey (UMDNJ)/Robert Wood Johnson Medical School & Rutgers University (New Jersey). He is also a Visiting Professor at the International Centre for Indoor Environment and Energy, Technical University of Denmark (DTU, Lyngby, Denmark).

  7. Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance 

    E-Print Network [OSTI]

    Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

    2004-01-01

    Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time...

  8. An Innovative Method for Dynamic Characterization of Fan FilterUnit Operation.

    SciTech Connect (OSTI)

    Xu, Tengfang

    2006-12-21

    Fan filter units (FFU) are widely used to deliver re-circulated air while providing filtration control of particle concentration in controlled environments such as cleanrooms, minienvironments, and operating rooms in hospitals. The objective of this paper is to document an innovative method for characterizing operation and control of an individual fan filter unit within its operable conditions. Built upon the draft laboratory method previously published [1] , this paper presents an updated method including a testing procedure to characterize dynamic operation of fan filter units, i.e., steady-state operation conditions determined by varied control schemes, airflow rates, and pressure differential across the units. The parameters for dynamic characterization include total electric power demand, total pressure efficiency, airflow rate, pressure differential across fan filter units, and airflow uniformity.

  9. Time-resolved LII signals from aggregates of soot particles levitated in room temperature air

    E-Print Network [OSTI]

    Mitrani, James M

    2015-01-01

    We observed and modeled time-resolved laser-induced incandescence (LII) signals from soot aggregates. Time-resolved LII signals were observed from research-grade soot particles, levitated in room temperature air. We were able to measure sizes and structural properties of our soot particles ex situ, and use those measurements as input parameters when modeling the observed LII signals. We showed that at low laser fluences, aggregation significantly influences LII signals by reducing conductive cooling to the ambient air. At moderate laser fluences, laser-induced disintegration of aggregates occurs, so the effects of aggregation on LII signals are negligible. These results can be applied to extend LII for monitoring formation of soot and nanoparticle aggregates.

  10. Airflow Simulation and Energy Analysis in Ventilated Room with a New Type of Air Conditioning 

    E-Print Network [OSTI]

    Liu, D.; Tang, G.; Zhao, F.

    2006-01-01

    Airflow simulation in one ventilated room with radiant heating and natural ventilation has been carried out. Three cases are compared: the closed room, the room with full openings, and the room with small openings. The ...

  11. Modeling of ECM Controlled Series Fan-powered VAV Terminal Units 

    E-Print Network [OSTI]

    Yin, Peng

    2011-10-21

    Semi-empirical models for series fan-powered variable air volume terminal units (FPTUs) were developed based on models of the primary, plenum, fan airflow and the fan power consumption. The experimental setups and test procedures were developed...

  12. Potential Global Benefits of Improved Ceiling Fan Energy Efficiency

    E-Print Network [OSTI]

    Sathaye, Nakul

    2014-01-01

    using genetic algorithm. Energy for Sustainable Development,induced by a room ceiling- fan. Energy and Buildings, 43(8),G. , 2010. Estimating Technical Energy Saving Potential from

  13. The Dwyer Series 640 air velocity transmitter is ideal for a wide range of HVAC measurement and control applications, particularly

    E-Print Network [OSTI]

    Berns, Hans-Gerd

    measurements, supply and exhaust fan tracking, industrial hygiene and clean-room systems, air pollution studiesThe Dwyer Series 640 air velocity transmitter is ideal for a wide range of HVAC measurement for use in reasonably clean and dry air streams, appli- cations include multi-point air velocity

  14. Performance of ECM controlled VAV fan powered terminal units 

    E-Print Network [OSTI]

    Cramlet, Andrew Charles

    2009-05-15

    Empirical performance models of fan airflow, primary airflow and power consumption were developed for series and parallel variable air volume fan powered terminal units. An experimental setup and test procedure were created to test the terminal...

  15. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01

    integrated with an air conditioner unit and air/water heatan air conditioner unit and air/water heat exchanger Source:system and a standard air/water heat exchanger. Figure A-

  16. International Program House Room Inventory (Double Room 101)

    E-Print Network [OSTI]

    Chen, Sheng-Wei

    Insect Killer 1,710 11 Trash Can 100 12 Air Conditioning 80,000 13 Fan 2,500 Tenant Signature : Sign Lighting 500 9 Insect Killer 1,710 10 Trash Can*2 100*2 11 Air Conditioning 80,000 12 Fan 2,500 Tenant Trash Can*2 100*2 12 Air Conditioning 80,000 13 Fan 2,500 Tenant Signature : Sign in Date Sign out Date

  17. Room air stratification in combined chilled ceiling and displacement ventilation systems.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01

    Environments. Proceedings of Indoor Air 2005: 10 thInternational Conference on Indoor Air Quality and Climate,displacement ventilation hybrid air conditioning system-

  18. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01

    the energy efficiency of air conditioning products isbetween the energy efficiency of air conditioning productsthe air conditioning testing facilities of energy efficiency

  19. Development of a High Efficiency Ceiling Fan 

    E-Print Network [OSTI]

    Parker, D. S.; Callahan, M. P.; Sonne, J. K.; Su, G. H.; Hibbs, B. D.

    2000-01-01

    The potential of ceiling fans to improve comfort during the cooling season is well documented (Rohles et al.. 1983; Fairey et al.. 1986). There are at least two cases: In the first where air conditioning is unavailable, adding ceiling fans may...

  20. Save Energy with Axial Fans 

    E-Print Network [OSTI]

    Monroe, R. C.

    1981-01-01

    point on horsepower, how and when are velocity recovery stacks effective, the effect of varying fan speed to improve efficiency, and tip clearance effects. The areas of interest to dry tower (air cooled heat exchanger) users would be the effect of inlet...

  1. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01

    shows that most foreign energy efficien- cy standards arethe measurement of the energy efficien- cies of air/air airshare consists of energy- efficient electric motor products.

  2. Fans for Cooling | Department of Energy

    Energy Savers [EERE]

    4F with no reduction in comfort. In temperate climates, or during moderately hot weather, ceiling fans may allow you to avoid using your air conditioner altogether. Install a...

  3. High Efficiency Fans and High Efficiency Electrical Motors 

    E-Print Network [OSTI]

    Breedlove, C. W.

    1989-01-01

    operates from 800 hours to 1500 hours per year or 15% of the year. Sixty percent of the connected horsepower is operating pneumatic air fans. These pneumatic fans transport the seed cotton, cotton lint, cottonseed and cotton trash throughout... efficiency will be consistent and ongoing. Since pneumat cs use 60% of the total power consumed in a cotton gin it seemed the most likely pace to improve efficiency. Each fan's sys em was redesigned and engineered. Not on y were old inefficient fans...

  4. Room air stratification in combined chilled ceiling and displacement ventilation systems.

    E-Print Network [OSTI]

    Schiavon, Stefano; Bauman, Fred; Tully, Brad; Rimmer, Julian

    2012-01-01

    does not affect thermal stratification in the room but theythermal comfort model suggest that greater stratificationthermal discomfort due to draft and excessive temperature stratification (

  5. Performance Assessment of Photovoltaic Attic Ventilator Fans

    Broader source: Energy.gov [DOE]

    A case study of photovoltaic attic ventilator fans was conducted on an occupied single family home in Central Florida. Two fans were installed at mid-summer in an instrumented home where attic air temperature, meteorological conditions and space cooling electric power were measured. The home already had an attic radiant barrier, but still experienced attic air temperatures in excess of 130oF.

  6. Research on Thermal Properties in a Phase Change Wallboard Room Based on Air Conditioning Cold Storage 

    E-Print Network [OSTI]

    Feng, G.; Li, W.; Chen, X.

    2006-01-01

    is lower than that of ordinary wall room by 1 to 2?, and PCW can lower the heat flow by 4.6W/m2. Combining phase change material with the building envelope can lower the indoor temperature, make the room thermally comfortable, and cut down the turn...

  7. Synchronous and Cogged Fan Belt Performance Assessment

    SciTech Connect (OSTI)

    Cutler, D.; Dean, J.; Acosta, J.

    2014-02-01

    The GSA Regional GPG Team commissioned the National Renewable Energy Laboratory (NREL) to perform monitoring of cogged V-belts and synchronous belts on both a constant volume and a variable air volume fan at the Byron G. Rodgers Federal Building and U.S. Courthouse in Denver, Colorado. These motor/fan combinations were tested with their original, standard V-belts (appropriately tensioned by an operation and maintenance professional) to obtain a baseline for standard operation. They were then switched to the cogged V-belts, and finally to synchronous belts. The power consumption by the motor was normalized for both fan speed and air density changes. This was necessary to ensure that the power readings were not influenced by a change in rotational fan speed or by the power required to push denser air. Finally, energy savings and operation and maintenance savings were compiled into an economic life-cycle cost analysis of the different belt options.

  8. Room Temperature Control During Season Switchover with Single Duct Variable Air Volume System Without Reheat 

    E-Print Network [OSTI]

    Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H.

    2003-01-01

    The Langford “A” building houses the College of Architecture on TAMU campus. There are ten singleduct variable air volume (VAV) air-handling units (AHUs) without reheat serving the building. The local pneumatic thermostats modulate the dampers...

  9. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01

    use, the water-side economizer and the air-side economizer.The air-side economizer takes advantage of the cool outdoorair is cool enough to provide total cooling. The water-side economizer

  10. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01

    86 Figure A-4: (a) Physical DEVap concept; (b)Illustration of DEVap air conditioningcontrolled ventilation DEVap Desiccant-enhanced evaporative

  11. Jianguo Fan

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformationJesse Bergkamp Graduate student Subtask 4 project: "Synthesis

  12. Development of a Fan-Filter Unit Test Standard, Laboratory Validations, and its Applications across Industries

    E-Print Network [OSTI]

    Xu, Tengfang

    2008-01-01

    Fan Filter Units for Cleanroom Applications. ” Building andFeedback Control in a Cleanroom. ” Building and Environment.energy costs dictate cleanroom design. CleanRooms, February

  13. Initial proof-of-principle for near room temperature Xe and Kr separation from air with MOFs

    SciTech Connect (OSTI)

    Thallapally, Praveen K.; Strachan, Denis M.

    2012-06-06

    Materials were developed and tested in support of the U.S. Department of Energy, Office of Nuclear Energy, Fuel Cycle Technology Separations and Waste Forms Campaign. Specifically, materials are being developed for the removal of Xenon and krypton from gaseous products of nuclear fuel reprocessing unit operations. During FY 2012, Three Metal organic framework (MOF) structures were investigated in greater detail for the removal and storage of Xe and Kr from air at room temperature. Our breakthrough measurements on Nickel based MOF could capture and separate parts per million levels of Xe from Air (40 ppm Kr, 78% N2, 21% O2, 0.9% Ar, 0.03% CO2). Similarly, the selectivity can be changed from Xe > Kr to Xe < Kr simply by changing the temperature in another MOF. Also for the first time we estimated the cost of the metal organic frameworks in bulk.

  14. Energy Savings in Buildings Using Air Movement and Allowing Floating Temperature in Rooms 

    E-Print Network [OSTI]

    Spain, S.

    1985-01-01

    The purpose of the research study was to determine if building loads could be reduced by using an intelligent controller rather than a thermostatic controller to operate heating and air conditioning equipment. In order to switch the equipment...

  15. Metal-air cell comprising an electrolyte with a room temperature ionic liquid and hygroscopic additive

    DOE Patents [OSTI]

    Friesen, Cody A.; Krishnan, Ramkumar; Tang, Toni; Wolfe, Derek

    2014-08-19

    An electrochemical cell comprising an electrolyte comprising water and a hydrophobic ionic liquid comprising positive ions and negative ions. The electrochemical cell also includes an air electrode configured to absorb and reduce oxygen. A hydrophilic or hygroscopic additive modulates the hydrophobicity of the ionic liquid to maintain a concentration of the water in the electrolyte is between 0.001 mol % and 25 mol %.

  16. Splashing phenomena of room temperature liquid metal droplet striking on the pool of the same liquid under ambient air environment

    E-Print Network [OSTI]

    Haiyan Li; Shengfu Mei; Lei Wang; Yunxia Gao; Jing Liu

    2013-09-04

    In this article, the fluid dynamics of room temperature liquid metal (RTLM) droplet impacting onto a pool of the same liquid in ambient air was investigated. A series of experiments were conducted in order to disclose the influence of the oxidation effect on the impact dynamics. The droplet shape and impact phenomenology were recorded with the aid of a high-speed digital camera. The impact energy stored in the splash structures was estimated via a theoretical model and several morphological parameters obtained from instantaneous images of the splash. It was observed that the droplet shape and the splashing morphology of RTLM were drastically different from those of water, so was the impact dynamics between room temperature LM pool and high temperature LM pool. The energy analysis disclosed that the height of the jet is highly sensitive to the viscosity of the fluid, which is subjected to the oxidation effect and temperature effect simultaneously, and thus perfectly explained the phenomena. These basic findings are important for the application of RTLM in a series of newly emerging technologies such as liquid metal based spray cooling, ink-jet printed electronics, interface material painting and coating, metallurgy, and 3D packages, etc.

  17. Record of Communication Concerning Ceiling Fan and Ceiling Fan...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Record of Communication Concerning Ceiling Fan and Ceiling Fan Light Kit Framework Document-Docket No. EERE-2012-BT-STD-0045 Record of Communication Concerning Ceiling Fan and...

  18. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    SciTech Connect (OSTI)

    Zhou, Nan; Fridley, David; Zheng, Nina; Pierrot, Andre

    2010-06-07

    In recent years China's energy consumption has increased rapidly. The problem of high energy consumption intensity and low energy utilization efficiency is serious, and the contradiction between economic development and energy and environmental resources has become increasingly acute, making energy conservation and consumption reduction an important society-wide concern. At the same time, global climate change has and will continue to have profound impacts on human survival and development, and is another major challenge to all countries. In order to accelerate China's energy conservation and emission reduction work, the National Leading Group to Address Climate Change, Energy Conservation and Emission Reduction was founded with Premier Wen Jiabao as the head, and the 'Comprehensive Work Program of Energy Conservation and Emission Reduction' and 'China's National Program of Addressing Climate Change' were issued, under which China's energy conservation and emission reduction work has been fully deployed. Efforts to promote energy efficiency have been further strengthened in all levels of government, and various policies and measures have progressively been issued and implemented. In addition, based on China's experience with implementing energy-saving priority strategies over the past 20+ years, our government established a goal of a 20% decrease in energy consumption per unit GDP in the 'Eleventh Five-year Development Plan'. Furthermore, in November 2009, in order to support global greenhouse gas emission reduction activities and promote China's low carbon economic development, the government established a further 40-50% reduction in energy consumption per unit GDP by 2020 compared to the year 2005. Improving energy utilization efficiency by scientific and technological progress will undoubtedly play an important role in achieving the above stated objectives. The improvement of energy efficiency of energy consuming products has always been an important component of all countries energy strategies. As we all know, a very large amount of total energy consumption is due to energy consuming products and equipment, which account for about 50% of China's total energy consumption. However, the current average energy utilization efficiency of this sector is only about 60%, 10 percent lower than the international advanced level. Therefore, China's energy consuming products and equipment sector holds great energy-saving potential. On the other hand, the energy supplied to these products is mainly from fossil fuel combustion, a major source of greenhouse gas (GHG) emissions. Therefore, improving the energy efficiency and augmenting the market share of market-dominant energy consuming products is of significant importance to achieving China's energy saving and emission reduction target and is an effective means to deal with energy and environmental constraints and climate change issues. Main energy consuming products generally include widely-used home appliances, industrial equipment, office equipment, transportation vehicles, etc. China is one of the major manufacturers and exporters of energy end-using products such as air-conditioners, refrigerators, televisions, etc. Their overall energy efficiency is comparatively low and the products are poorly designed, leading to great energy-saving potential. For example, electricity consumption of air conditioners accounts for about 20% of China's total electricity consumption and 40% of the summer electricity peak load in large and medium cities. However, less than 5% of units sold in the domestic market in 2009 reached the standard's highly efficient level of grade 2 above. The electricity consumption of electric motors and their related drive systems accounts for about 60% of China's total electricity consumption; however, less than 2% of the domestic market share consists of energy-efficient electric motor products. Promoting the energy efficiency and market shares of main energy-consuming products has become an important determinant of achieving energy conservation and emission reduc

  19. New Energy Efficiency Standards for Furnace Fans to Reduce Carbon...

    Office of Environmental Management (EM)

    by at least 3 billion metric tons in total by 2030, equal to more than a year's carbon pollution from the entire U.S. electricity system. Furnace fans are used to circulate air...

  20. Interaction of Plutonium with Diverse Materials in Moist Air and Nitrogen-Argon Atmospheres at Room Temperature

    SciTech Connect (OSTI)

    John M. Haschke; Raymond J. Martinez; Robert E. Pruner II; Barbara Martinez; Thomas H. Allen

    2001-04-01

    Chemical and radiolytic interactions of weapons-grade plutonium with metallic, inorganic, and hydrogenous materials in atmospheres containing moist air-argon mixtures have been characterized at room temperature from pressure-volume-temperature and mass spectrometric measurements of the gas phase. A reaction sequence controlled by kinetics and gas-phase composition is defined by correlating observed and known reaction rates. In all cases, O{sub 2} is eliminated first by the water-catalyzed Pu + O{sub 2} reaction and H{sub 2}O is then consumed by the Pu + H{sub 2}O reaction, producing a gas mixture of N{sub 2}, argon, and H{sub 2}. Hydrogen formed by the reaction of water and concurrent radiolysis of hydrogenous materials either reacts to form PuH{sub 2} or accumulates in the system. Accumulation of H{sub 2} is correlated with the presence of hydrogenous materials in liquid and volatile forms that are readily distributed over the plutonium surface. Areal rates of radiolytic H{sub 2} generation are determined and applied in showing that modest extents of H{sub 2} production are expected for hydrogenous solids if the contact area with plutonium is limited. The unpredictable nature of complex chemical systems is demonstrated by occurrence of the chloride-catalyzed Pu + H{sub 2}O reaction in some tests and hydride-catalyzed nitriding in another.

  1. Fan-less long range alpha detector

    DOE Patents [OSTI]

    MacArthur, D.W.; Bounds, J.A.

    1994-05-10

    A fan-less long range alpha detector is disclosed which operates by using an electrical field between a signal plane and the surface or substance to be monitored for air ions created by collisions with alpha radiation. Without a fan, the detector can operate without the possibility of spreading dust and potential contamination into the atmosphere. A guard plane between the signal plane and the electrically conductive enclosure and maintained at the same voltage as the signal plane, reduces leakage currents. The detector can easily monitor soil, or other solid or liquid surfaces. 2 figures.

  2. Best Practice for Energy Efficient Cleanrooms: Fan-FilterUnits

    SciTech Connect (OSTI)

    Xu, Tengfang

    2005-06-15

    The HVAC systems in cleanrooms may use 50 percent or more of the total cleanroom energy use. Fan energy use accounts for a significant portion (e.g., over 50%) of the HVAC energy use in cleanrooms such as ISO Classes 3, 4, or 5. Three types of air-handling systems for recirculating airflows are commonly used in cleanrooms: (1) fan-tower systems with pressurized plenum, (2) ducted HEPA systems with distributed-fans, and (3) systems with fan-filter units. Because energy efficiency of the recirculation systems could vary significantly from system type to system type, optimizing aerodynamic performance in air recirculation systems appears to be a useful approach to improve energy efficiency in cleanrooms. Providing optimal airflows through careful planning, design and operation, including air change rate, airflow uniformity, and airflow speed, is important for controlling particle contamination in cleanrooms. In practice, the use of fan-filter units (FFUs) in the air-handling system is becoming more and more popular because of this type of system may offer a number of advantages. Often modular and portable than traditional recirculation airflow systems, FFUs are easier to install, and can be easily controlled and monitored to maintain filtration performance. Energy efficiency of air handling systems using fan-filter units can, however, be lower than their counterparts and may vary significantly from system to system because of the difference in energy performance, airflow paths, and the operating conditions of FFUs.

  3. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    E-Print Network [OSTI]

    Phadke, Amol

    2014-01-01

    Current and future electricity demand from Room ACs andof ACs to the Peak Electricity Demand In this section, weseasonal variation in electricity demand in both sectors,

  4. Modeling of Electronically Commutated Motor Controlled Fan-powered Terminal Units 

    E-Print Network [OSTI]

    Edmondson, Jacob Lee

    2011-02-22

    : Dr. Dennis O?Neal Empirical models of airflow and power consumption were developed for series and parallel variable air volume fan powered terminal units (FPTUs). An experimental setup and test procedure were developed to test the terminal... (THD) was also recorded and presented. For the series terminal units, models were developed for fan airflow, fan power, and primary airflow. The models for fan airflow all had R2 values above 0.987. The iv models for fan power all had R2 values...

  5. Performance Optimization of a Fan System- Overcoming Impacts of Modified Design Criteria Due to Regulatory Requirements and Changed Operating Conditions 

    E-Print Network [OSTI]

    Wroblewski, R. G.; Preis, F.; Smith, R.

    1997-01-01

    by fully opening the fan inlet box damper as well as reduce the fan speed by replacing the belt drive. 94 ESL-IE-97-04-16 Proceedings from the Nineteenth Industrial Energy Technology Conference, Houston, TX, April 23-24, 1997 E-Tube ID Fan The E... to improve process efficiency. Combustion Air Fan Replace inlet ducts. Install a flow-grid metering device. Replace the outlet damper with a variable inlet vane control. Reduce the fan speed by changing the belt drive. Dryer ID Fan Open inlet box...

  6. Fan System Assessment Tool Introduction

    Broader source: Energy.gov [DOE]

    This presentation provides an introduction to the Fan System Assessment Tool (FSAT). With FSAT, users can calculate the amount of energy used by their fan system; determine system efficiency; and quantify the savings potential of an upgraded system.

  7. Avoiding 100 New Power Plants by Increasing Efficiency of Room Air Conditioners in India: Opportunities and Challenges

    SciTech Connect (OSTI)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar

    2014-06-19

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40percent cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  8. Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges

    SciTech Connect (OSTI)

    Phadke, Amol; Abhyankar, Nikit; Shah, Nihar

    2013-10-15

    Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

  9. An Evaluation of Improper Refrigerant Charge on the Performance of a Split System Air Conditioner with a Thermal Expansion Valve 

    E-Print Network [OSTI]

    Farzad, M.; O'Neal, D. L.

    1989-01-01

    and was exhausted by the unit fan back into the room through the outdoor coil. PSYCHROMETRIC ROOMS The psychrometric rooms could simulate all testing conditions required for air conditioning and heat pump performance testing. Dew point and room temperatures could..., Including Heat Pumps (1979)[7]. The entering dry bulb temperature for the outdoor coil for steady state and cyclic tests was 82? +/-0.3 F DB and 20% relative humidity. The steady state tests were repeated for outdoor temperatures of 90?, 95?, and 100?F...

  10. Importance of the Return Air Opening to Degree of Turbulence in a I-Grade Clean Operating Room 

    E-Print Network [OSTI]

    Cheng, S.

    2006-01-01

    In this paper, a high Reynold K-etwo equation model has been used. The range of return air openings that can be used has been induced by numerical simulation to influence the return air opening and degree of turbulence in an I-Grade clean operating...

  11. Performance of VAV Parallel Fan Powered Terminal Units: Experimental Results and Models 

    E-Print Network [OSTI]

    Furr, J.; O'Neal, D.; Davis, M.; Bryant, J.; Cramlet, A.

    2008-01-01

    to develop empirical models of airflow, power, and leakage of both parallel and series fan power terminal units. These models are suitable for use in annual energy use models of variable air volume systems in commer- cial buildings. This paper provides a... was the development of empirical models of power and airflow output for parallel and series fan powered terminal units at typical operating pres- sures. An experimental setup was developed and used to test fan powered terminal units from three manufacturers...

  12. Fan System Assessment- End User Training

    Office of Energy Efficiency and Renewable Energy (EERE)

    Optimizing industrial fan systems can take on many forms, but any fan optimization project must meet the needs of the process. This self-paced workshop highlights the benefits of fan system...

  13. Promising Technology: Variable-Air-Volume Ventilation System

    Broader source: Energy.gov [DOE]

    Variable-air-volume (VAV) ventilation saves energy compared to a constant-air-volume (CAV) ventilation system, mainly by reducing energy consumption associated with fans.

  14. How the Number and Placement of Sensors Controlling Room Air Distribution Systems Affect Energy Use and Comfort 

    E-Print Network [OSTI]

    Wang, D.; Arens, E.; Webster, T.; Shi, M.

    2002-01-01

    model are diffuser design ratio (DDR) and load volume ratio (LVR); dependent variables are temperature gradient in the occupied zone (the region from 4 to 67 in. from the floor), and the difference between the average occupied zone and supply air... temperatures. For swirl diffusers, the regression model can be written as follows: DDRLVR 231 - (1) DDR2 + (2) where ftTTT 5-=delta saTTT -=delta - 5 and V , LVR is proportional to the ratio of load and zone supply airflow...

  15. Performance of VAV Fan Powered Terminal Units: Experimental Results and Models for Parallel Units 

    E-Print Network [OSTI]

    Furr, J.; O'Neal, D.; Davis, M.; Bryant, J.; Cramlet, A.

    2008-01-01

    Empirical models of airflow output, power consumption, and primary airflow were developed for parallel fan powered variable air volume terminal units at typical operating pres- sures. Both 8 in. (203 mm) and 12 in. (304 mm) primary air inlet terminal units... from three manufacturers were evaluated. Generalized models were developed from the experimental data with coefficients varying by size and manufacturer. Fan power and airflow data were collected at down- stream static pressures over a range from 0...

  16. Energy Efficient Single Stack Exhaust Fan Systems (E3S3F) 

    E-Print Network [OSTI]

    Wang, G.; Liu, M.

    2001-01-01

    exhaust airflow. 1 Patent application pending Stack height is a critical issue in preventing local toxic air contamination. Design rules and criteria have been developed based on recent research.... Therefore, most exhaust systems are designed as constant volume systems with exit velocity of 3,000 fpm. A constant speed fan is typically used. When the airflow from the fume hood is less than the design volume, a make-up air damper at the inlet of the fan...

  17. Performance of VAV Fan Powered Terminal Units: Experimental Results and Models for Series Units 

    E-Print Network [OSTI]

    Furr, J.; O'Neal, D.; Davis, M.; Bryant, J.; Cramlet, A.

    2008-01-01

    Empirical models of airflow output and power consump- tion were developed for series fan powered variable air volume terminal units at typical operating pressures. Terminal units with 8 in. (203 mm) and 12 in. (304 mm) primary air inlets from three different... manufacturers were evaluated. Generalized models were developed from the experimental data with coef- ficients varying by size and manufacturer. Fan power and airflow data were collected at downstream static pressures of 0.25 w.g. (63 Pa). Upstream static...

  18. Indoor Air Quality Observations in Public Schools 

    E-Print Network [OSTI]

    McClure, J. D.; Estes, J. M.

    1990-01-01

    pressurize the crawl space. Sane of the llnderfloor fans were not opera* (failed) an3 this results in mist ~OQI: air flawing into the building through the apenFngs in the pip* chases anl aperative underfloor fan ducts. Turn off the underfloar fans, sedl...

  19. Development of a Laboratory Verified Single-Duct VAV System Model with Fan Powered Terminal Units Optimized Using Computational Fluid Dynamics 

    E-Print Network [OSTI]

    Davis, Michael A.

    2011-10-21

    Single Duct Variable Air Volume (SDVAV) systems use series and parallel Fan Powered Terminal Units to control the air flow in conditioned spaces. This research developed a laboratory verified model of SDVAV systems that ...

  20. Double Ducted Fan (DDF) as a Novel Ducted Fan Inlet Lip Separation Control Device

    E-Print Network [OSTI]

    Camci, Cengiz

    Double Ducted Fan (DDF) as a Novel Ducted Fan Inlet Lip Separation Control Device Ali Akturk computational study of a novel ducted fan inlet flow conditioning concept that will significantly improve the performance and controllability of VTOL UAVs and many other ducted fan based systems. The new concept

  1. Engine having hydraulic and fan drive systems using a single high pressure pump

    DOE Patents [OSTI]

    Bartley, Bradley E. (Manito, IL); Blass, James R. (Bloomington, IL); Gibson, Dennis H. (Chillicothe, IL)

    2000-01-01

    An engine comprises a hydraulic system attached to an engine housing that includes a high pressure pump and a hydraulic fluid flowing through at least one passageway. A fan drive system is also attached to the engine housing and includes a hydraulic motor and a fan which can move air over the engine. The hydraulic motor includes an inlet fluidly connected to the at least one passageway.

  2. Study on Energy Saving of the Interlayer Ventilation Walla Used in Clean Operation Rooms 

    E-Print Network [OSTI]

    Feng, J.; Lian, Z.; Hou, Z.

    2006-01-01

    Recovery energy of the exhaust in air conditioning is very important to clean operating rooms. In disinfected operating rooms, we often use completely fresh air conditioning system in order to maintain cleanliness. All the return air of the air...

  3. Air-bridged photonic crystal slabs at visible and near-infrared wavelengths K. B. Crozier,1 Virginie Lousse,2,3 Onur Kilic,3 Sora Kim,3 Shanhui Fan,3 and Olav Solgaard3

    E-Print Network [OSTI]

    Air-bridged photonic crystal slabs at visible and near-infrared wavelengths K. B. Crozier,1 manuscript received 15 February 2006; published 30 March 2006 Air-bridged photonic crystal slabs of the transmission spectra of air-bridged photonic crystal slabs with free space illumination using collimated

  4. Fresh air indoors

    SciTech Connect (OSTI)

    Kull, K.

    1988-09-01

    This article describes and compares ventilation systems for the control of indoor air pollution in residential housing. These include: local exhaust fans, whole-house fans, central exhaust with wall ports, and heat-recovery central ventilation (HRV). HRV's have a higher initial cost than the other systems but they are the only ones that save energy. Homeowners are given guidelines for choosing the system best suited for their homes in terms of efficiency and payback period.

  5. Sandia Energy - Hongyou Fan Chosen for Prestigious Lecture on Creating

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II)Geothermal Energy & DrillingNanomaterials Hongyou Fan Chosen for

  6. Fan Systems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12, 2015Executive Order14, 20111,FYDepartment of5 November 2015Fan

  7. Advanced low noise cooling fans

    SciTech Connect (OSTI)

    Spek, H.F. van der; Nelissen, P.J.M.

    1995-02-01

    The results from an intensive research program show that it is possible to reduce the sound power level of cooling fans by 15 dB(A) by altering blade cord width and swept leading and trailing edge lines. Combination with the reduction of the pressure drop can result in a step of 20 dB(A) and a reduction with 25 percent of the absorbed power. Testing was conducted in accordance with recognized international measuring standards and the results will be presented, including consequences for cooling tower and condenser design.

  8. Ceiling Fan | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION JEnvironmentalBowerbank,CammackFLIR Jump to:RAPIDCavallo Energy JumpCeiling Fan Jump to:

  9. Parametric System Curves: Correlations Between Fan Pressure Rise and Flow for Large Commercial Buildings

    SciTech Connect (OSTI)

    Sherman, Max; Wray, Craig

    2010-05-19

    A substantial fraction of HVAC energy use in large commercial buildings is due to fan operation. Fan energy use depends in part on the relationship between system pressure drop and flow through the fan, which is commonly called a "system curve." As a step toward enabling better selections of air-handling system components and analyses of common energy efficiency measures such as duct static pressure reset and duct leakage sealing, this paper shows that a simple four-parameter physical model can be used to define system curves. Our model depends on the square of the fan flow, as is commonly considered. It also includes terms that account for linear-like flow resistances such as filters and coils, and for supply duct leakage when damper positions are fixed or are changed independently of static pressure or fan flow. Only two parameters are needed for systems with variable-position supply dampers (e.g., VAV box dampers modulating to control flow). For these systems, reducing or eliminating supply duct leakage does not change the system curve. The parametric system curve may be most useful when applied to field data. Non-linear techniques could be used to fit the curve to fan pressure rise and flow measurements over a range of operating conditions. During design, when measurements are unavailable, one could use duct design calculation tools instead to determine the coefficients.

  10. News Room

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefieldSulfateSciTechtail.Theory ofDid you notHeatMaRIEdioxideUser Work Featured onNews ReleasesRoom

  11. Cooling with a Whole House Fan | Department of Energy

    Office of Environmental Management (EM)

    circulating fans provide acceptable summer comfort for many families, even in hot weather. In addition to whole house fans, the ducts of your central heating and cooling...

  12. A COMPUTATIONAL AND EXPERIMENTAL ANALYSIS OF A DUCTED FAN USED IN VTOL UAV SYSTEMS

    E-Print Network [OSTI]

    Camci, Cengiz

    diameter ducted fan. They have concentrated on the performance of ducted fan VTOL vehicles in crosswind

  13. Fan-fold shielded electrical leads

    DOE Patents [OSTI]

    Rohatgi, R.R.; Cowan, T.E.

    1996-06-11

    Disclosed are fan-folded electrical leads made from copper cladded Kapton, for example, with the copper cladding on one side serving as a ground plane and the copper cladding on the other side being etched to form the leads. The Kapton is fan folded with the leads located at the bottom of the fan-folds. Electrical connections are made by partially opening the folds of the fan and soldering, for example, the connections directly to the ground plane and/or the lead. The fan folded arrangement produces a number of advantages, such as electrically shielding the leads from the environment, is totally non-magnetic, and has a very low thermal conductivity, while being easy to fabricate. 3 figs.

  14. Fan-fold shielded electrical leads

    DOE Patents [OSTI]

    Rohatgi, Rajeev R. (Mountain View, CA); Cowan, Thomas E. (Livermore, CA)

    1996-01-01

    Fan-folded electrical leads made from copper cladded Kapton, for example, with the copper cladding on one side serving as a ground plane and the copper cladding on the other side being etched to form the leads. The Kapton is fan folded with the leads located at the bottom of the fan-folds. Electrical connections are made by partially opening the folds of the fan and soldering, for example, the connections directly to the ground plane and/or the lead. The fan folded arrangement produces a number of advantages, such as electrically shielding the leads from the environment, is totally non-magnetic, and has a very low thermal conductivity, while being easy to fabricate.

  15. Asymmetrical-fan tranmission CT on SPECT to derive {mu}-maps for attenuation correction

    SciTech Connect (OSTI)

    Loncaric, S.; Huang, G.; Ni, B. [Rush-Presbyterian-St. Luke`s Medical Center, Chicago, IL (United States)] [and others

    1994-05-01

    For proper attenuation correction of SPECT images, an appropriate {mu}-map properly registered with each imaging slices is needed. Among the many techniques for {mu}-map derivation, simultaneous or sequential fan-beam transmission CT (TCT), on the same SPECT system with the same acquisition settings, have advantages of being practical while ensuring registration. However, the problems are: (1) limited FOV for thoracic imaging, projection would be truncated with a typical size detector, (2) lack of room for placing the transmission source in many SPECT systems. We have developed a new sampling scheme to solve the problems mentioned above. This scheme uses an asymmetrical-fan geometry (AFG), which samples only half of the field, the other half would be sampled after an 180{degrees} detector rotation. This technique completes the minimum sampling requirement in a 360{degrees} detector rotation and yields a relatively large FOV defined by the outside edge of the sampling fan. We have confirmed the feasibility of the AFG sampling on a 3-head SPECT system to provide a large FOV for TCT of most patient. The TCT sampling scheme is achieved with an asymmetrical-fan collimator. We have developed the required new reconstruction algorithms and derived excellent reconstructed images of phantoms and human subjects. We propose to have this technique implemented in a short and fast transmission scan in a multi-head SPECT system, after emission imaging, because the detectors have to be pulled out to make room for the transmission source. The imaging field can even exceed the full field size of the detector. MS would be possible when an obtuse sampling fan is formed by shifting the source outward further, provided the central FOV is properly covered with a supplementary sampling scheme, e.g., using another TCT with a fan-beam collimator on another one of the detectors.

  16. Waveguides in inverted opal photonic Virginie Lousse 1,2 and Shanhui Fan 1

    E-Print Network [OSTI]

    Fan, Shanhui

    Waveguides in inverted opal photonic crystals Virginie Lousse 1,2 and Shanhui Fan 1 1 Ginzton phenomena are investigated in an inverted opal photonic crystal made of interpenetrating air spheres, coated, and simulations," Phys. Rev. E 71, 026,605 (2005). 12. V.N. Astratov, et al, "Optical spectroscopy of opal

  17. Economizer Applications in Dual-Duct Air-Handling Units 

    E-Print Network [OSTI]

    Joo, I.; Liu, M.

    2002-01-01

    for dual-fan, dual-duct air-handling units. The economizer has significant heating energy penalties for single-fan, dual-duct air-handling units. The penalties are higher than the cooling energy savings when the cold airflow is less than the hot airflow...

  18. 96 ASHRAE Transactions: Research Current duct design methods for variable air volume

    E-Print Network [OSTI]

    -round electrical energy cost of the fan. The initial cost of the fan is not included. The calculation procedure to determine duct sizes, overall system pressure drop, and fan energy cost. However, in VAV systems for effective, energy-efficient, and comfortable heating, ventilat- ing, and air-conditioning (HVAC) systems

  19. Multiple current peaks in room-temperature atmospheric pressure homogenous dielectric barrier discharge plasma excited by high-voltage tunable nanosecond pulse in air

    SciTech Connect (OSTI)

    Yang, De-Zheng; Wang, Wen-Chun; Zhang, Shuai; Tang, Kai; Liu, Zhi-jie; Wang, Sen

    2013-05-13

    Room temperature homogenous dielectric barrier discharge plasma with high instantaneous energy efficiency is acquired by using nanosecond pulse voltage with 20-200 ns tunable pulse width. Increasing the voltage pulse width can lead to the generation of regular and stable multiple current peaks in each discharge sequence. When the voltage pulse width is 200 ns, more than 5 organized current peaks can be observed under 26 kV peak voltage. Investigation also shows that the organized multiple current peaks only appear in homogenous discharge mode. When the discharge is filament mode, organized multiple current peaks are replaced by chaotic filament current peaks.

  20. Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology

    SciTech Connect (OSTI)

    Not Available

    1993-11-01

    The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

  1. GROUP STUDY ROOMS GROUP STUDY ROOMS

    E-Print Network [OSTI]

    Young, R. Michael

    STAFF AREA LEVEL 2 LOBBY bookBot GROUP STUDY ROOMS GROUP STUDY ROOMS GROUPSTUDYROOMS RAIN GARDEN LIBRARY TECHNOLOGY AND MEDIA SPACES GROUP STUDY EVENT AND MEETING SPACES STAFF ONLY STAIRS INSTITUTES AND UNIVERSITY CENTERS #12;GROUP STUDY ROOMS MAKER SPACE LEARNING COMMONS LOCKERS LOCKERS LOCKERS TEACHING

  2. Cooling efficiency of a brushless direct current stand fan

    E-Print Network [OSTI]

    Yang, Bin; Schiavon, Stefano; Sekhar, Chandra; Cheong, David; Tham, Kwok Wai; Nazaroff, William W

    2015-01-01

    3.1.2. Cooling Fan Efficiency (CFE) index Fig. 5 displaysH, Zhai Y. Enabling energy-efficient approaches to thermalIntroduction of a cooling-fan efficiency index. HVAC&R Res [

  3. Cooling efficiency of a brushless direct current stand fan

    E-Print Network [OSTI]

    Yang, Bin; Schiavon, Stefano; Sekhar, Chandra; Cheong, David; Tham, Kwok Wai; Nazaroff, William W

    2015-01-01

    eq (°C) Front Side Fig. 4. Cooling effect comparison betweenmanikin distance. 3.1.2. Cooling Fan Efficiency (CFE) indexdevices [41-42]. Local cooling for front and side fan-

  4. Healthcare Energy: Spotlight on Fans and Pumps | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Fans and Pumps Healthcare Energy: Spotlight on Fans and Pumps Chilled water pumps at a central plant. Image by Warren Gretz, NREL06196 Chilled water pumps at a central plant....

  5. Ultra-short nacelles for low fan pressure ratio propulsors

    E-Print Network [OSTI]

    Peters, Andreas, Ph. D. Massachusetts Institute of Technology

    2014-01-01

    This thesis addresses the uncharted inlet and nacelle design space for low pressure ratio fans for advanced aeroengines. A key feature in low fan pressure ratio (FPR) propulsors with short inlets and nacelles is the increased ...

  6. Solar Decathlon 2015: Energy.gov Fan Favorite Poll Results |...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Solar Decathlon 2015: Energy.gov Fan Favorite Poll Results Solar Decathlon 2015: Energy.gov Fan Favorite Poll Results October 22, 2015 - 10:10am Addthis West Virginia University...

  7. DOE Publishes Request for Information for Ceiling Fans

    Broader source: Energy.gov [DOE]

    The Department of Energy has published a request for information regarding energy conservation standards for ceiling fans.

  8. Introduction of a Cooling Fan Efficiency Index

    E-Print Network [OSTI]

    Schiavon, Stefano; Melikov, Arsen

    2009-01-01

    Refrigerating and Air-Conditioning Engineers, Inc. (Refrigerating and Air-Conditioning Engineers, Inc. (Refrigerating and Air-Conditioning Engineers, Inc. (

  9. DOUBLE DUCTED FAN (DDF) Cengiz Camci and Ali Akturk

    E-Print Network [OSTI]

    Camci, Cengiz

    DOUBLE DUCTED FAN (DDF) By Cengiz Camci and Ali Akturk A technology description document a novel ducted fan inlet flow conditioning concept that will significantly improve the performance" and many other ducted fan based systems. The new concept that will significantly reduce the inlet lip

  10. Adjustable Speed- A Tool for Saving Energy Losses in Pumps, Fans, Fans, Blowers and Compressors 

    E-Print Network [OSTI]

    Hickok, H. N.

    1985-01-01

    Petroleum and chemical plants of today are effectively cutting energy losses in their plants thermally, electrically, and mechanically in their process equipment. In rotating process equipment such as pumps, fans, compressors, and blowers, much...

  11. Design, testing and two-dimensional flow modeling of a multiple-disk fan

    SciTech Connect (OSTI)

    Engin, Tahsin; Oezdemir, Mustafa; Cesmeci, Sevki [Department of Mechanical Engineering, The University of Sakarya, Esentepe Campus, 54187 Sakarya (Turkey)

    2009-11-15

    A multiple-disk Tesla type fan has been designed, tested and analyzed two-dimensionally using the conservation of angular momentum principle. Experimental results showed that such multiple-disk fans exhibited exceptionally low performance characteristics, which could be attributed to the low viscosity, tangential nature of the flow, and large mechanical energy losses at both suction and discharge sections that are comparable to the total input power. By means of theoretical analysis, local and overall shearing stresses on the disk surfaces have been determined based on tangential and radial velocity distributions of the air flow of different volume flow rates at prescribed disk spaces and rotational speeds. Then the total power transmitted by rotating disks to air flow, and the power acquired by the air flow in the gap due to transfer of angular momentum have been obtained by numerically integrating shearing stresses over the disk surfaces. Using the measured shaft and hydraulic powers, these quantities were utilized to evaluate mechanical energy losses associated with the suction and discharge sections of the fan. (author)

  12. Better Unitary Equipment Air-Handlers for Efficiency and Humidity Control 

    E-Print Network [OSTI]

    Sachs, H. M.

    2002-01-01

    procedure gives too little credit for advanced air handlers that reduce air conditioning load and facilitate adaptive humidity control through automatic fan speed adjustment. DC permanent magnet variable speed motors have much lower market share than less...

  13. Room Air Conditioners | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onRAPID/Geothermal/Exploration/ColoradoRemsenburg-Speonk, NewMichigan: EnergyRocklinRohm and HaasRomoland,Rooks

  14. Room Air Conditioners | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann Jackson About1996HowFOA Applicantof YearsRevolving Loan Fundsand

  15. Room Air Conditioners | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankADVANCED MANUFACTURINGEnergy BillsNo. 195 -Rob Roberts About Us Rob Roberts -Ronald E.

  16. Room Air Conditioners | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirley Ann JacksonDepartment ofOffice|inWestMay 13, 2015 TheTechnologies-2015 UpdateremovetoC.RodneyA

  17. Air Exchange Rates in New Energy-Efficient Manufactured Housing 

    E-Print Network [OSTI]

    Hadley, D. L.; Bailey, S. A.

    1990-01-01

    manufactured homes. A standard door fan pressurization technique was used to estimate shell leakiness, and a passive perfluorocarbon tracer technique was used to estimate overall air exchange rates. A measurement of the designated whole-house exhaust system...

  18. Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles 

    E-Print Network [OSTI]

    Xu, K.; Liu, M.; Wang, G.; Wang, Z.

    2007-01-01

    energy for fan, cooling and heating energy. In this paper a simple energy consumption model is established for AHU systems during the economizer and then a optimal supply air temperature control is developed to minimize the total cost of the mechanical...

  19. Qualification of Fan Generated Duct Rumble Noise: Part 1: Test Facility(RP 1219) 

    E-Print Network [OSTI]

    Kading, J.; Mann, A.; Pate, M.B.

    2008-01-01

    :4. The transition was enclosed in a 53” by 93” by 3’ tall box constructed from MDF and lined with 2” duct board fiber- glass. The box was designed to isolate the transition duct from break in noise from the fan room. The fiberglass insulation on the inside... (MDF) shell that was mounted on a 2x4 structure. The interior consisted of three layers. The first was fiberglass board 2’x 4’ x 2”, these boards were cut to be stacked and fill in between the MDF and the duct lining insu- lation. The second layer...

  20. Fan System Assessment Tool | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12, 2015Executive Order14, 20111,FYDepartment of5 November 2015Fan System

  1. Underfloor air distribution: thermal stratification

    E-Print Network [OSTI]

    Webster, T.; Bauman, Fred; Reese, J.

    2002-01-01

    Air Distribution: Thermal Stratification By Tom Webster, Pthermal bypassing of convective loads that occurs above the stratificationthermal plumes that develop over heat sources in the room. A stratification

  2. DOE Publishes Final Rule for Residential Furnace Fan Test Procedure...

    Broader source: Energy.gov (indexed) [DOE]

    (DOE) has published a final rule regarding test procedures for residential furnace fans. 79 FR 500 (January 3, 2014). Find more information on the rulemaking, including milestones,...

  3. Energy Conservation Standards for Ceiling Fan Light Kits Notice...

    Office of Environmental Management (EM)

    for Ceiling Fan Light Kits; Notice of Proposed Rulemaking 2014-05-16 Issuance: Test Procedures for Integrated Light-Emitting Diode Lamps; Supplemental Notice of Proposed Rulemaking...

  4. Case Study: The Effective Use of an Extensive Logical rule Based Data Analytics Approach in Establishing Root Cause of Performance Issues in Widespread Deployments of Unitary Space Air Conditioning Units 

    E-Print Network [OSTI]

    Brady, N.

    2013-01-01

    Today a significant percentage of office spaces are air conditioned using widely deployed unitary systems, either Fan Coil Units (FCU) or Variable Air Volume (VAV) boxes, to achieve high degrees of air conditioned zonal control. However establishing...

  5. Fans for Cooling | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuelsof Energy Services » Program ManagementAct4FacilityFact SheetFall andFans

  6. Air Quality

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room News Publications Traditional KnowledgeAgenda Agenda NERSC UserAgustin Mihi andAir Leaks inAir

  7. Experimental optimization of cooling-tower-fan control based on field data. Master's thesis

    SciTech Connect (OSTI)

    Herman, D.L.

    1991-04-01

    Energy costs continue to play an important role in the decision-making process for building design and operation. Since the chiller, cooling tower fans, and associated pumps consume the largest fraction of energy in a heating, ventilating, and air-conditioning (HVAC) system, the control of these components is of major importance in determining building energy use. A significant control parameter for the chilled water system is the minimum entering condenser water set point temperature at which the cooling tower fans are cycled on and off, several studies have attempted to determine the optimum value for this minimum set point temperature, but direct measurements are not available to validate these studies. The purpose of this study was to experimentally determine the optimum minimum entering condenser water set point temperature from field data based on minimum energy consumption and to validate a chilled water system analytical model previously developed in earlier work. The total chiller system electrical consumption (chiller and cooling tower fan energy) was measured for four entering condensor water set point temperatures (70, 75, 80, and 85 deg F). The field results were compared to results obtained using an analytical model previously developed in a thesis entitled Optimized Design of a Commercial Building Chiller/Cooling Tower System, written by Joyce.

  8. Experimental Evaluation of Installed Cooking Exhaust Fan Performance

    E-Print Network [OSTI]

    Singer, Brett C.

    2011-01-01

    and  results  for  B6.   Exp Burners RR LF LR RR LF RR RF RFHigh High High Fan (cfm) Burner Fire Btu/hr A- 50 Fan/Plumeand  results  for  D1.   Exp Burners RR LR LF RF RF LR LR RF

  9. Heuristics for Balancing Turbine Fans Samir V. Amiouny

    E-Print Network [OSTI]

    Bartholdi III, John J.

    Reiger, 1986. In some cases, such as in the constructionof hydraulic, steam or gas turbines, fan blades to counteract the residual un- balance. For gas and steam turbines, this is necessary not only when the engineHeuristics for Balancing Turbine Fans Samir V. Amiouny John J. Bartholdi, III John H. Vande Vate

  10. An Innovative Method for Dynamic Characterization of Fan Filter Unit Operation.

    E-Print Network [OSTI]

    Xu, Tengfang

    2006-01-01

    large fan-filter units for cleanroom applications. BuildingFeedback Control in a Cleanroom. ” Building and Environment.Fan filter unit (FFU), cleanroom, energy efficiency, airflow

  11. Lessons learned in modeling Underfloor Air Distribution system

    E-Print Network [OSTI]

    Lee, Kwang Ho; Schiavon, Stefano; Webster, Tom; Bauman, Fred; Feng, Jingjuan; Hoyt, Tyler

    2011-01-01

    room air stratification and thermal comfort. INTRODUCTIONsuch as thermal decay and room air stratification, properlystratification and its implications on energy performance; 5) implications of system design and operation on thermal

  12. Method for fabricating fan-fold shielded electrical leads

    DOE Patents [OSTI]

    Rohatgi, R.R.; Cowan, T.E.

    1994-12-27

    Fan-folded electrical leads made from copper cladded Kapton, for example, with the copper cladding on one side serving as a ground plane and the copper cladding on the other side being etched to form the leads. The Kapton is fan folded with the leads located at the bottom of the fan-folds. Electrical connections are made by partially opening the folds of the fan and soldering, for example, the connections directly to the ground plane and/or the lead. The fan folded arrangement produces a number of advantages, such as electrically shielding the leads from the environment, is totally non-magnetic, and has a very low thermal conductivity, while being easy to fabricate. 3 figures.

  13. Costs and benefits of energy efficiency improvements in ceiling fans

    SciTech Connect (OSTI)

    Shah, Nihar; Sathaye, Nakul; Phadke, Amol; Letschert, Virginie

    2013-10-15

    Ceiling fans contribute significantly to residential electricity consumption, especially in developing countries with warm climates. The paper provides analysis of costs and benefits of several options to improve the efficiency of ceiling fans to assess the global potential for electricity savings and green house gas (GHG) emission reductions. Ceiling fan efficiency can be cost-effectively improved by at least 50% using commercially available technology. If these efficiency improvements are implemented in all ceiling fans sold by 2020, 70 terawatt hours per year could be saved and 25 million metric tons of carbon dioxide equivalent (CO2-e) emissions per year could be avoided, globally. We assess how policies and programs such as standards, labels, and financial incentives can be used to accelerate the adoption of efficient ceiling fans in order to realize potential savings.

  14. Method for fabricating fan-fold shielded electrical leads

    DOE Patents [OSTI]

    Rohatgi, Rajeev R. (Mountain View, CA); Cowan, Thomas E. (Livermore, CA)

    1994-01-01

    Fan-folded electrical leads made from copper cladded Kapton, for example, with the copper cladding on one side serving as a ground plane and the copper cladding on the other side being etched to form the leads. The Kapton is fan folded with the leads located at the bottom of the fan-folds. Electrical connections are made by partially opening the folds of the fan and soldering, for example, the connections directly to the ground plane and/or the lead. The fan folded arrangement produces a number of advantages, such as electrically shielding the leads from the environment, is totally non-magnetic, and has a very low thermal conductivity, while being easy to fabricate.

  15. Bioenergy 2015 Press Room

    Broader source: Energy.gov [DOE]

    This U.S. Department of Energy Bioenergy 2015 online press room provides contacts, information, and resources to members of the media who cover Bioenergy 2015 conference-related news.

  16. Air-Side Energy Use Calculations for Four HVAC Systems: Dual Duct Constant Volume (DDCAV), Dual Duct Variable Volume (DDVAV), Constant Volume with Reheat (CAVRH), Variable Volume with Reheat (VAVRH), Four Pipe Fan Coil Unit (FC), Four Pipe Induction Unit (FI), and Single Zone (SZ) Systems, Revised June 2002 

    E-Print Network [OSTI]

    Haberl, J. S.; Bou-Saada, T. E.; Saman, N. F.

    2001-01-01

    This report contains engineering calculations for seven (7) air-side, heating, ventilating and air conditioning systems (HVAC) systems, including: dual duct constant volume (DDCAV), dual duct variable volume (DDVAV), ...

  17. Cooling Tower Energy Conservation Through Hydraulic Fan Drives 

    E-Print Network [OSTI]

    Dickerson, J.

    1991-01-01

    Many companies offer gearboxes, shafts, and couplings for cooling tower fan drives, with little or no innovation. These companies have traditionally been purchased with an emphasis on cost and not "Return on Investment!" In the past, when energy...

  18. Evolution of high-redshift quasars Xiaohui Fan

    E-Print Network [OSTI]

    Colorado at Boulder, University of

    Evolution of high-redshift quasars Xiaohui Fan Steward Observatory, The University of Arizona redshift quasars, including the evolution of quasar density and luminosity function, the evolution. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 666 3. Evolution of quasar density and luminosity function at high

  19. Cooling with a Whole House Fan | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    families, even in hot weather. In addition to whole house fans, the ducts of your central heating and cooling system can be modified to provide whole house cooling. How Whole House...

  20. Modeling and ecodesigning crossflow ventilation fans with Mathematica

    E-Print Network [OSTI]

    Argentini, Gianluca

    2010-01-01

    The efficiency of a simple model of crossflow fan is maximized when the geometry depends on a design parameter. The flow field is numerically computed using a Galerkin method for solving a Poisson partial differential equation.

  1. Exploring Maximum Humidity Control and Energy Conservation Opportunities with Single Duct Single Zone Air-Handling Units 

    E-Print Network [OSTI]

    Zhou, J.; Wei, G.; Turner, W. D.; Deng, S.; Claridge, D.

    2006-01-01

    the outside air. However, it also involves major ductwork changes. 2.3 Variable speed control of supply airflow A variable speed drive (VFD) saves fan power by slowing down the fan speed and delivering less supply air to the conditioned space during... by adjusting the supply fan speed. However, if the space cooling load drops below the point where the supply airflow reaches the minimum flow required for proper ventilation, the supply air temperature has to be raised to keep the space temperature from...

  2. Improved Air Volume Control Logic for VAV Systems 

    E-Print Network [OSTI]

    Wei, G.; Claridge, D. E.; Sakuri, Y.; M. Liu

    2000-01-01

    In a VAV (variable air volume) system, the set point of the static pressure (usually measured at 213 downstream of the main supply air duct) is maintained by modulating the fan speed or inlet guide vane position. The set point of the static pressure...

  3. Development of a Fan-Filter Unit Test Standard, LaboratoryValidations, and its Applications across Industries

    SciTech Connect (OSTI)

    Xu, Tengfang

    2006-10-20

    Lawrence Berkeley National Laboratory (LBNL) is now finalizing the Phase 2 Research and Demonstration Project on characterizing 2-foot x 4-foot (61-cm x 122-cm) fan-filter units in the market using the first-ever standard laboratory test method developed at LBNL.[1][2][3] Fan-filter units deliver re-circulated air and provide particle filtration control for clean environments. Much of the energy in cleanrooms (and minienvironments) is consumed by 2-foot x 4-foot (61-cm x 122-cm) or 4-foot x 4-foot (122-cm x 122-cm) fan-filter units that are typically located in the ceiling (25-100% coverage) of cleanroom controlled environments. Thanks to funding support by the California Energy Commission's Industrial Program of the Public Interest Energy Research (PIER) Program, and significant participation from manufacturers and users of fan-filter units from around the world, LBNL has developed and performed a series of standard laboratory tests and reporting on a variety of 2-foot x 4-foot (61-cm x 122-cm) fan-filter units (FFUs). Standard laboratory testing reports have been completed and reported back to anonymous individual participants in this project. To date, such reports on standard testing of FFU performance have provided rigorous and useful data for suppliers and end users to better understand, and more importantly, to quantitatively characterize performance of FFU products under a variety of operating conditions.[1] In the course of the project, the standard laboratory method previously developed at LBNL has been under continuous evaluation and update.[2][3] Based upon the updated standard, it becomes feasible for users and suppliers to characterize and evaluate energy performance of FFUs in a consistent way.

  4. FREH CONFERENCE ROOMS Scheduling Requirements

    E-Print Network [OSTI]

    Pittendrigh, Barry

    1/12/2015 FREH CONFERENCE ROOMS Scheduling Requirements: The 1st or 2nd Floor Operations Clerk it in the location or the body of the room reservation. Schedule ALL conference rooms and/or equipment needs ONLY" dumpster outside by the loading dock. Please CANCEL the conference room reservation

  5. Air Leakage and Air Transfer Between Garage and Living Space

    SciTech Connect (OSTI)

    Rudd, Armin

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed.

  6. Air pollution study of Laredo Customs Station 

    E-Print Network [OSTI]

    Welling, Vidyadhar Yeshwant

    1972-01-01

    was found between these results. This gives credence to the results obtained on the proposed ventilation system. The report discusses in length various vent1lation systems and their effects. It proposes the installation of an east-to-west forced air... CONCLUSIONS AND RECOMMENDATIONS. REFERENCES. ' VITA. Page V1 13 21 33 49 77 83 85 LIST OF TABLES Table l Comparative Sampling Results. 2 Fan Effect. 3 Existing Forced Air System Effect Page 39 45 4 Velocity Distribution Outside and Inside...

  7. Tips: Air Ducts | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    tubes in the walls, floors, and ceilings; it carries the air from your home's furnace and central air conditioner to each room. Ducts are made of sheet metal, fiberglass, or other...

  8. Submitting Organization Hongyou Fan Sandia National Laboratories

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation ofAlbuquerque|SensitiveAprilPhotonStructureStudentsSubmitting Batch  2007

  9. Cooling Effects of Fans | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room News PublicationsAuditsClusterInformationContract Management Princeton16,558.1CoolDesignWhy Do

  10. Performance Assessment of Photovoltaic Attic Ventilator Fans 

    E-Print Network [OSTI]

    Parker, D. S.; Sherwin, J. R.

    2000-01-01

    Controlling summer attic heat gain is important to reducing air conditioning energy use in homes in hot-humid climates. Both heat transfer through ceilings and t attic duct systems can make up a large part of peak cooling demand, Attic ventilation...

  11. Blue fan palm distribution and seed removal patterns in three desert oases of northern Baja California, Mexico

    E-Print Network [OSTI]

    Wehncke, Elisabet V.; López-Medellín, Xavier; Ezcurra, Exequiel

    2010-01-01

    DOI 10.1007/s11258-009-9682-4 Blue fan palm distribution anddistribution patterns of the blue fan palm, Brahea armata,evaluating (i) the levels of blue fan palm seed removal by

  12. Air Leakage and Air Transfer Between Garage and Living Space

    SciTech Connect (OSTI)

    Rudd, A.

    2014-09-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  13. Performance and Stability Analysis of a Shrouded-Fan UAV

    E-Print Network [OSTI]

    de Divitiis, Nicola

    2009-01-01

    This paper deals with the estimation of the performance and stability for a shrouded-fan unmanned rotorcraft whose mission profile also prescribes the flight in ground effect. The not so simple estimation of the aerodynamic coefficients and of the thrust in the various situations makes the performance calculation and the stability analysis difficult tasks. This is due to the strong interaction between the fan flow and shroud that causes quite different flow structures about the airframe depending on flight conditions. A further difficulty is related to the ground effect which produces substantial modifications in the rotor thrust and aerodynamic coefficients. To evaluate performance and stability, two models have been developed. One determines the aerodynamic coefficients of the shroud, whereas the other one calculates thrust and moment of the rotors system. Both models take into account the mutual interference between fan flow and fuselage and ground effect. Performance and stability are then discussed with ...

  14. Numerical Analysis of Heat and Moisture Transfer in Underground Air-conditioning Systems 

    E-Print Network [OSTI]

    Wang, Q.; Miao, X.; Cheng, B.; Fan, L.

    2006-01-01

    In view of the influence of humidity of room air on room heat load, indoor environment and building energy consumption in underground intermittent air-conditioning systems, numerical simulation was used to dynamically analyze the coupling condition...

  15. NATURAL CONVECTION IN ROOM GEOMETRIES

    SciTech Connect (OSTI)

    Gadgil, A.; Bauman, Fred; Kammerud, R.; Ruberg, K.

    1980-06-01

    Computer programs have been developed to numerically simulate natural convection in room geometries in two and three dimensions. The programs have been validated using published data from the literature, results from a full-scale experiment performed at Massachusetts Institute of Technology, and results from a small-scale experiment reported here. One of the computer programs has been used to study the influence of natural convection on the thermal performance of a single thermal zone in a direct-gain passive solar building. The results indicate that the building heating loads calculated by standard building energy analysis methods may be in error by as much as 50% as a result of their use of common assumptions regarding the convection processes which occur in an enclosure. It is also found that the convective heat transfer coefficients between the air and the enclosure surfaces can be substantially different from the values assumed in the standard building energy analysis methods, and can exhibit significant variations across a given surface.

  16. Advanced Energy-Efficient Filtration: Fan Filter Unit

    SciTech Connect (OSTI)

    Xu, Tengfang

    2005-10-01

    The objective of this project is to provide assistance in development of a standard test procedure for fan-filter units, which are gaining popularity for use in California cleanrooms. In particular, LBNL carried out collaboration with various stakeholders in the industry and took a lead in developing a draft standard method for testing the energy performance of fan-filter units, and provided assistance to California public utility companies by testing the draft method in PG&E's testing facility. Through testing more units in the future with a robust standard method, baseline performance information can be developed for use in possible energy incentive programs.

  17. Amateur experts: International fan labor in Swedish independent music

    E-Print Network [OSTI]

    Baym, Nancy K.; Burnett, Robert

    2009-09-01

    , and comprehensibility of Swedish indie are buttressed by many others fans’ minimalist practices. Amateur Experts -- 4 Together, these fans serve as expert filters as they sift, sort, label, translate, rate and annotate a large, disorganized, and geographically... one’: It’s A Trap.” The site receives as many as 4,000 daily hits and as many as 30,000 unique visitors a month, many from within Scandinavia. Says Roig: No one else does what I do or even comes close, so I seem to have positioned myself as a vital...

  18. DOE Publishes Notice of Proposed Rulemaking for Residential Furnace Fans Energy Conservation Standards

    Broader source: Energy.gov [DOE]

    The Department of Energy has published a notice of proposed rulemaking regarding energy conservation standards for residential furnace fans.

  19. Flexibility of Commercial Building HVAC Fan as Ancillary Service for Smart Grid

    E-Print Network [OSTI]

    Maasoumy, Mehdi

    2013-01-01

    Efficient Building Control Systems, Smart Grid and AircraftCommercial Building HVAC Fan as Ancillary Service for Smart

  20. Modeling, Control, and Flight Testing of a Small Ducted Fan Aircraft

    E-Print Network [OSTI]

    Johnson, Eric N.

    1 Modeling, Control, and Flight Testing of a Small Ducted Fan Aircraft Eric N. Johnson* and Michael A. Turbe Georgia Institute of Technology, Atlanta, GA, 30332 Small ducted fan autonomous vehicles for the GTSpy, a small ducted fan autonomous vehicle based on the Micro Autonomous Systems' Helispy

  1. Fan Aerodynamic Performance Guarantees: Do Your Policies, Procedures and Penalties Provide Adequate Certainty? 

    E-Print Network [OSTI]

    Kaufman, S. G.; Martin, V.; Falk, M. A.

    2004-01-01

    With few exceptions, fan vendors do not provide a written guarantee regarding aerodynamic performance. Some fan vendors even go so far as to state in their terms and conditions of sale that fan performance is not guaranteed unless it is specifically...

  2. Cellular Responses in Sea Fan Corals: Granular Amoebocytes React to Pathogen and Climate Stressors

    E-Print Network [OSTI]

    Harvell, Catherine Drew

    Cellular Responses in Sea Fan Corals: Granular Amoebocytes React to Pathogen and Climate Stressors amoebocyte responses indicate that sea fan corals use cellular defenses to combat fungal infection SF, Peters EC, Harvell CD (2008) Cellular Responses in Sea Fan Corals: Granular Amoebocytes React

  3. CEBAF Control Room Renovation

    SciTech Connect (OSTI)

    Michael Spata; Anthony Cuffe; Thomas Oren

    2005-03-22

    The Machine Control Center (MCC) at Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) was constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on work-flow processes and ergonomic attributes. The renovation was performed in two phases during the summer of 2004, with one phase occurring during machine operations and the latter, more extensive phase, occurring during our semi-annual shutdown period. The new facility takes advantage of advances in display technology, analog and video signal management, server technology, ergonomic workspace design, lighting engineering, acoustic ceilings and raised flooring solutions to provide a marked improvement in the overall environment of machine operations.

  4. CEBAF Control Room Renovation

    SciTech Connect (OSTI)

    Michael Spata; Thomas Oren

    2005-05-01

    The Machine Control Center at Jefferson Lab's Continuous Electron Beam Accelerator Facility was initially constructed in the early 1990s and based on proven technology of that era. Through our experience over the last 15 years and in our planning for the facilities 12 GeV upgrade we reevaluated the control room environment to capitalize on emerging visualization and display technologies and improve on workflow processes and ergonomic attributes. This effort also sets the foundation for the redevelopment of the accelerator's control system to deliver high reliability performance with improvements in beam specifications management and information flow. The complete renovation was performed over a three-week period with no interruption to beam operations. We present the results of this effort.

  5. A Snapshot of Public Web Services Jianchun Fan & Subbarao Kambhampati

    E-Print Network [OSTI]

    Kambhampati, Subbarao

    A Snapshot of Public Web Services Jianchun Fan & Subbarao Kambhampati Department of Computer}@asu.edu Abstract Web Service Technology has been developing rapidly as it provides a flexible application-to-application interaction mechanism. Several ongoing research efforts focus on various aspects of web service technology

  6. Amazon Fan biomarker evidence against the Pleistocene rainforest refuge hypothesis?

    E-Print Network [OSTI]

    Jones, Peter JS

    Drilling Program Leg 155 Site 942 on the Amazon Fan is an ideal location for monitoring palaeoclimatic is constrained between À31% and À34%, which is well within the isotopic range occupied by C3 vegetation in the Amazon Basin. This paper provides another test of one of these theories, namely the `Pleistocene tropical

  7. Measured Natural Cooling Enhancement of a While House Fan 

    E-Print Network [OSTI]

    Parker, D. S.

    1994-01-01

    An experimental study was carried out in the summer of 1991 to investigate the natural cooling potential of use of a whole house fan in Central Florida's hot and humid climate. The residential building, in Cocoa Beach, FL, is typical of much...

  8. Cosmogenic 10 Cl geochronology of offset alluvial fans

    E-Print Network [OSTI]

    Frankel, Kurt L.

    Cosmogenic 10 Be and 36 Cl geochronology of offset alluvial fans along the northern Death Valley the first geochronologically determined slip rate for the NDVFZ. Our study focuses on the Red Wall Canyon Pleistocene. In situ terrestrial cosmogenic 10 Be and 36 Cl geochronology was used to date the Red Wall Canyon

  9. Fan System Effects: How Fan Ductwork Design Impacts Overall System Efficiency and What the Approach Should be for Optimization 

    E-Print Network [OSTI]

    Martin, V.

    2009-01-01

    expectations once they are installed on the systems for which they have been sold. This is primarily due to the adverse aerodynamic impact of the inlet or outlet connections on the performance capacity of the fan and thus on the overall system efficiency...

  10. 133AMAZON FAN MASS-TRANSPORT AND AVULSION DEPOSITS REVIEW OF THE TIMING AND CAUSES OF THE AMAZON-FAN MASS TRANSPORT

    E-Print Network [OSTI]

    Jones, Peter JS

    of sequence stratigraphy, namely that changes in sea level control basin sedimentation and the emplacement: Amazon Fan, avulsion, slope failure, Pleistocene, sequence stratigraphy External Controls on Deep

  11. Modeling the Air Flow in the 3410 Building Filtered Exhaust Stack System

    SciTech Connect (OSTI)

    Recknagle, Kurtis P.; Barnett, J. M.; Suffield, Sarah R.

    2013-01-23

    Additional ventilation capacity has been designed for the 3410 Building filtered exhaust stack system. The updated system will increase the number of fans from two to three and will include ductwork to incorporate the new fan into the existing stack. Stack operations will involve running various two-fan combinations at any given time. The air monitoring system of the existing two-fan stack was previously found to be in compliance with the ANSI/HPS N13.1-1999 standard, however it is not known if the modified (three-fan) system will comply. Subsequently, a full-scale three-dimensional (3-D) computational fluid dynamics (CFD) model of the modified stack system has been created to examine the sampling location for compliance with the standard. The CFD modeling results show good agreement with testing data collected from the existing 3410 Building stack and suggest that velocity uniformity and flow angles will remain well within acceptance criteria when the third fan and associated ductwork is installed. This includes two-fan flow rates up to 31,840 cfm for any of the two-fan combinations. For simulation cases in which tracer gas and particles are introduced in the main duct, the model predicts that both particle and tracer gas coefficients of variance (COVs) may be larger than the acceptable 20 percent criterion of the ANSI/HPS N13.1-1999 standard for each of the two-fan, 31,840 cfm combinations. Simulations in which the tracers are introduced near the fans result in improved, though marginally acceptable, COV values for the tracers. Due to the remaining uncertainty that the stack will qualify with the addition of the third fan and high flow rates, a stationary air blender from Blender Products, Inc. is considered for inclusion in the stack system. A model of the air blender has been developed and incorporated into the CFD model. Simulation results from the CFD model that includes the air blender show striking improvements in tracer gas mixing and tracer particle dispersion. The results of these simulations suggest the air blender should be included in the stack system to ensure qualification of the stack.

  12. Effect of a Radiant Panel Cooling System on Indoor Air Quality of a Conditioned Space 

    E-Print Network [OSTI]

    Mohamed, E.; Abdalla, K. N.

    2010-01-01

    This paper discusses the effect of a radiant cooling panel system on an indoor air quality (IAQ) of a conditioned space. In this study, ceiling radiant cooling panel, mechanical ventilation with fan coil unit (FCU) and 100% fresh air are used...

  13. Rating of Mixed Split Residential Air Conditioners 

    E-Print Network [OSTI]

    Domanski, P. A.

    1988-01-01

    require that manufac- turers derive cooling ratings for unitary systems by testing a sample of sufficient size to meet certain specified statistical confidence levels. For split unitary systems comprising an outdoor unit and an indoor coil assembly...(95), SEER, and recommended indoor volumetric flow rate of air, are publicly available. The procedure also assumee that the matched indoor section is available for inspection and evaluation of the indoor coil capacity and the indoor fan power...

  14. Air Pollution, ATS555 Colorado State University

    E-Print Network [OSTI]

    Collett Jr., Jeffrey L.

    Air Pollution, ATS555 Colorado State University Fall 2014 Mondays and Wednesdays @ 4:00 ­ 5:30 Room://ramct.colostate.edu/) Textbooks: Air Pollution: Its Origin and Control, 3rd Edition, by Wark, Warner and Davis, Addison Wesley. Specific objectives include: 1. Develop an understanding of types and sources of air pollution. 2. Examine

  15. LAB 3 Cleanroom Fan and Filters Analysis for the Supports

    SciTech Connect (OSTI)

    Cease, H.; /Fermilab

    1998-05-08

    A 1400 lb blower fan and a 2700 lb filter box are to be supported at Lab 3. The support structure is a framework that suspends from the building wall to the cleanroom and to a washroom. The framework is made of welded 4-inch x 8-inch x 1/4-inch rectangular A36 steel tube. Welds are to be standard prequalified welds as by AISC. The main support frame is approximately 7-feet off the floor and welded onto the top of 10 columns. A deflection and stress study was performed on the planned structure. A scaled plan view is given in drawing 3823.113-MD-358764. The heaviest loaded beams were labeled with a letter designation and were studied for beam deflections and stresses. The 4-inch x 8-inch rectangular tube was also used for the substructure for the fan and filter mounts and to support a temporary floor grating during maintenance.

  16. Evaluation of Retrofit Variable-Speed Furnace Fan Motors

    SciTech Connect (OSTI)

    Aldrich, R.; Williamson, J.

    2014-01-01

    In conjunction with the New York State Energy Research and Development Authority (NYSERDA) and Proctor Engineering Group, Ltd. (PEG), the Consortium for Advanced Residential Buildings (CARB) has evaluated the Concept 3 (tm) replacement motors for residential furnaces. These brushless, permanent magnet (BPM) motors can use much less electricity than their PSC (permanent split capacitor) predecessors. This evaluation focuses on existing homes in the heating-dominated climate of upstate New York with the goals of characterizing field performance and cost-effectiveness. The results of this study are intended to be useful to home performance contractors, HVAC contractors, and home efficiency program stakeholders. The project includes eight homes in and near Syracuse, NY. Tests and monitoring was performed both before and after fan motors were replaced. Average fan power reductions were approximately 126 Watts during heating and 220 Watts during cooling operation. Over the course of entire heating and cooling seasons, these translated into average electric energy savings of 163 kWh. Average cost savings were $20 per year. Homes where the fan was used outside of heating and cooling mode saved an additional $42 per year on average. Results indicate that BPM replacement motors will be most cost-effective in HVAC systems with longer run times and relatively low duct static pressures. More dramatic savings are possible if occupants use the fan-only setting when there is no thermal load. There are millions of cold-climate, U.S. homes that meet these criteria, but the savings in most homes tested in this study were modest.

  17. Fan System Assessment Tool Introduction | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12, 2015Executive Order14, 20111,FYDepartment of5 November 2015 PURPOSEFactFan

  18. Low-Flow Liquid Desiccant Air Conditioning: General Guidance and Site Considerations

    SciTech Connect (OSTI)

    Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.

    2014-09-01

    Dehumidification or latent cooling in buildings is an area of growing interest that has been identified as needing more research and improved technologies for higher performance. Heating, ventilating, and air-conditioning (HVAC) systems typically expend excessive energy by using overcool-and-reheat strategies to dehumidify buildings. These systems first overcool ventilation air to remove moisture and then reheat the air to meet comfort requirements. Another common strategy incorporates solid desiccant rotors that remove moisture from the air more efficiently; however, these systems increase fan energy consumption because of the high airside pressure drop of solid desiccant rotors and can add heat of absorption to the ventilation air. Alternatively, liquid desiccant air-conditioning (LDAC) technology provides an innovative dehumidification solution that: (1) eliminates the need for overcooling and reheating from traditional cooling systems; and (2) avoids the increased fan energy and air heating from solid desiccant rotor systems.

  19. Innovative Systems for Solar Air Conditioning of Buildings 

    E-Print Network [OSTI]

    Kessling, W.; Peltzer, M.

    2004-01-01

    Solar air conditioning is an attractive technology to achieve comfortable room conditions, especially in hot and sunny climates. In particular air conditioning systems based on sorption technologies offer several advantages as they can be designed...

  20. Building America Technology Solutions for New and Existing Homes: Air Leakage and Air Transfer Between Garage and Living Space

    Office of Energy Efficiency and Renewable Energy (EERE)

    In this project, Building Science Corporation worked with production home builder K. Hovnanian to conduct testing at a single-family home in Waldorf, Maryland, constructed in accordance with the 2009 International Residential Code. The team used automated fan pressurization and pressure monitoring techniques to conduct a series of 25 tests to measure the garage and house air leakage and pressure relationships and the garage-to-house air leakage.

  1. The 'Room within a Room' Concept for Monitored Warhead Dismantlement

    SciTech Connect (OSTI)

    Tanner, Jennifer E.; Benz, Jacob M.; White, Helen; McOmish, Sarah; Allen, Keir; Tolk, Keith; Weeks, George E.

    2014-12-01

    Over the past 10 years, US and UK experts have engaged in a technical collaboration with the aim of improving scientific and technological abilities in support of potential future nuclear arms control and non-proliferation agreements. In 2011 a monitored dismantlement exercise provided an opportunity to develop and test potential monitoring technologies and approaches. The exercise followed a simulated nuclear object through a dismantlement process and looked to explore, with a level of realism, issues surrounding device and material monitoring, chain of custody, authentication and certification of equipment, data management and managed access. This paper focuses on the development and deployment of the ‘room-within-a-room’ system, which was designed to maintain chain of custody during disassembly operations. A key challenge for any verification regime operating within a nuclear weapon complex is to provide the monitoring party with the opportunity to gather sufficient evidence, whilst protecting sensitive or proliferative information held by the host. The requirement to address both monitoring and host party concerns led to a dual function design which: • Created a controlled boundary around the disassembly process area which could provide evidence of unauthorised diversion activities. • Shielded sensitive disassembly operations from monitoring party observation. The deployed room-within-a-room was an integrated system which combined a number of chain of custody technologies (i.e. cameras, tamper indicating panels and enclosures, seals, unique identifiers and radiation portals) and supporting deployment procedures. This paper discusses the bounding aims and constraints identified by the monitoring and host parties with respect to the disassembly phase, the design of the room-within-a-room system, lessons learned during deployment, conclusions and potential areas of future work. Overall it was agreed that the room-within-a-room approach was effective but the individual technologies used to create the system deployed during this exercise required further development.

  2. Pump and Fan Technology Characterization and R&D Assessment ...

    Office of Environmental Management (EM)

    Standard for Small, Large, and Very Large Air-Cooled Commercial Package Air Conditioning and Heating Equipment; Notice of Proposed Rulemaking and Public Meeting Motor...

  3. Reading Room | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Energy Public Reading Room 1166 Athens Tech Road Elberton, GA 30635-6711 Contact: Joel Seymour Phone: 706-213-3800 Fax: 706-213-3884 Email: joels@sepa.doe.gov Strategic Petroleum...

  4. Nuclear reactor control room construction

    DOE Patents [OSTI]

    Lamuro, Robert C. (Pittsburgh, PA); Orr, Richard (Pittsburgh, PA)

    1993-01-01

    A control room 10 for a nuclear plant is disclosed. In the control room, objects 12, 20, 22, 26, 30 are no less than four inches from walls 10.2. A ceiling 32 contains cooling fins 35 that extend downwards toward the floor from metal plates 34. A concrete slab 33 is poured over the plates. Studs 36 are welded to the plates and are encased in the concrete.

  5. Nuclear reactor control room construction

    DOE Patents [OSTI]

    Lamuro, R.C.; Orr, R.

    1993-11-16

    A control room for a nuclear plant is disclosed. In the control room, objects labelled 12, 20, 22, 26, 30 in the drawing are no less than four inches from walls labelled 10.2. A ceiling contains cooling fins that extend downwards toward the floor from metal plates. A concrete slab is poured over the plates. Studs are welded to the plates and are encased in the concrete. 6 figures.

  6. Standard Methods of Characterizing Performance of Fan Filter Units, Version 3.0

    E-Print Network [OSTI]

    Xu, Tengfang

    2007-01-01

    Feedback Control in a Cleanroom. ” Building and Environment.Fan Filter Units for Cleanroom Applications. ” Building andused in the filter and cleanroom industry, and provides

  7. 2015-03-26 Issuance: Fans and Blowers ASRAC Working Group; Notice...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Register publication controls. This document is being made available through the Internet solely as a means to facilitate the public's access to this document. ASRAC Fans and...

  8. Alliant Energy Interstate Power and Light (Gas and Electric)...

    Broader source: Energy.gov (indexed) [DOE]

    Replacement: 50 Dishwasher Replacement: 20 Freezer: 25 Room Air Conditioner: 25 Water Heater: 50 Electric Heat Pump Water Heaters: 100 Circulating Fans: 25 - 75...

  9. Residential Energy Efficiency Rebates (Offered by 5 Utilities)

    Broader source: Energy.gov [DOE]

     For residential customers, rebates are available for ENERGY STAR ceiling fans, clothes washers, decorative light strings, dehumidifiers, dishwashers, refrigerators, room air conditioners, and he...

  10. Development of a room air conditioner design model 

    E-Print Network [OSTI]

    Penson, Steven Brad

    1988-01-01

    AND RECOMMENDATIONS. Page . 12 . 12 . 20 . 33 . 38 . 48 . 50 . 56 Conclusions. Recommendations. REFERENCES APPENDIX A . 57 . 57 . 59 . 61 VITA . 66 LZST OP TABLES Table Page 2. 1 Major output parameters from the ORNL model 3. 1 Effect of tube.... Efficiency improvements are evaluated with the aid of a computer model. The model chosen for this analysis was the Oak Ridge National Laboratory (ORNL) heat pump model [5] . The ORNL Heat Pump Design Model is a FORTRAN computer program developed...

  11. An Analysis of Efficiency Improvements in Room Air Conditioner 

    E-Print Network [OSTI]

    O'Neal, D. L.; Penson, S. B.

    1988-01-01

    for an Energy-Efficient Economy Washington, DC ABSTRACT Reliable monitoring and measurement of the energy savings resulting from the installation of combined heat and power (CHP) systems and power recovered from waste energy (recycled energy) projects... is becoming increasingly important. As a growing number of states and now the federal government look to mandatory energy efficiency portfolio programs such as an Energy Efficiency Resource Standard (EERS), CHP and waste heat recovery stands to play a...

  12. Columbia University Hazardous Waste Room Inspection Report

    E-Print Network [OSTI]

    Jia, Songtao

    Storage Area Hazardous Waste Room Inspection Report Location: Bldg. Room: Date: Inspected ByColumbia University Hazardous Waste Room Inspection Report Flammable Storage Area Lack Pack always closed while holding hazardous wastes? Comment: 12. Are containers labeled? Date

  13. Perfluorocarbon tracer method for air-infiltration measurements

    DOE Patents [OSTI]

    Dietz, R.N.

    1982-09-23

    A method of measuring air infiltration rates suitable for use in rooms of homes and buildings comprises the steps of emitting perfluorocarbons in the room to be measured, sampling the air containing the emitted perfluorocarbons over a period of time, and analyzing the samples at a laboratory or other facility.

  14. A prototype fan-beam optical CT scanner for 3D dosimetry

    SciTech Connect (OSTI)

    Campbell, Warren G.; Rudko, D. A.; Braam, Nicolas A.; Jirasek, Andrew [University of Victoria, Victoria, British Columbia V8P 5C2 (Canada); Wells, Derek M. [British Columbia Cancer Agency, Vancouver Island Centre, Victoria, British Columbia V8R 6V5 (Canada)

    2013-06-15

    Purpose: The objective of this work is to introduce a prototype fan-beam optical computed tomography scanner for three-dimensional (3D) radiation dosimetry. Methods: Two techniques of fan-beam creation were evaluated: a helium-neon laser (HeNe, {lambda} = 543 nm) with line-generating lens, and a laser diode module (LDM, {lambda} = 635 nm) with line-creating head module. Two physical collimator designs were assessed: a single-slot collimator and a multihole collimator. Optimal collimator depth was determined by observing the signal of a single photodiode with varying collimator depths. A method of extending the dynamic range of the system is presented. Two sample types were used for evaluations: nondosimetric absorbent solutions and irradiated polymer gel dosimeters, each housed in 1 liter cylindrical plastic flasks. Imaging protocol investigations were performed to address ring artefacts and image noise. Two image artefact removal techniques were performed in sinogram space. Collimator efficacy was evaluated by imaging highly opaque samples of scatter-based and absorption-based solutions. A noise-based flask registration technique was developed. Two protocols for gel manufacture were examined. Results: The LDM proved advantageous over the HeNe laser due to its reduced noise. Also, the LDM uses a wavelength more suitable for the PRESAGE{sup TM} dosimeter. Collimator depth of 1.5 cm was found to be an optimal balance between scatter rejection, signal strength, and manufacture ease. The multihole collimator is capable of maintaining accurate scatter-rejection to high levels of opacity with scatter-based solutions (T < 0.015%). Imaging protocol investigations support the need for preirradiation and postirradiation scanning to reduce reflection-based ring artefacts and to accommodate flask imperfections and gel inhomogeneities. Artefact removal techniques in sinogram space eliminate streaking artefacts and reduce ring artefacts of up to {approx}40% in magnitude. The flask registration technique was shown to achieve submillimetre and subdegree placement accuracy. Dosimetry protocol investigations emphasize the need to allow gel dosimeters to cool gradually and to be scanned while at room temperature. Preliminary tests show that considerable noise reduction can be achieved with sinogram filtering and by binning image pixels into more clinically relevant grid sizes. Conclusions: This paper describes a new optical CT scanner for 3D radiation dosimetry. Tests demonstrate that it is capable of imaging both absorption-based and scatter-based samples of high opacities. Imaging protocol and gel dosimeter manufacture techniques have been adapted to produce optimal reconstruction results. These optimal results will require suitable filtering and binning techniques for noise reduction purposes.

  15. Hillery-type squeezing in fan-states

    E-Print Network [OSTI]

    Minh Duc Truong; Ba An Nguyen

    2004-03-29

    We study the Hillery-type, i.e. $N$-th power, amplitude squeezing in the fan-state $| \\xi ;2k,f>_{F}$ characterized by $\\xi \\in \\mathcal{C}$, $k=1,2,3,...$ and $f$ a nonlinear operator-valued function. We show that for a given $k$ there exists a critical $\\xi_c$ such that for $0<|\\xi|\\leq|\\xi_c|$ squeezing occurs simultaneously in $2k$ directions for the powers $N$ which are a multiple of $2k$. This result does not depend on the concrete form of $f$, i.e. it holds true for both $f\\equiv 1$ and $f\

  16. Shanghai Fan Qie Trading Ltd | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page| Open Energy Information Serbia-Enhancing Capacity for Low EmissionTianhong Silicon MaterialNew MaterialEco EnergyFan

  17. Room Temperature Dispenser Photocathode Using Elemental Cesium

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Room Temperature Dispenser Photocathode Using Elemental Cesium Room Temperature Dispenser Photocathode Using Elemental Cesium Los Alamos National Laboratory (LANL) researchers have...

  18. Integrated Ice Storage/Sprinkler HVAC System Sharply Cuts Energy Costs and Air-Distribution First Costs 

    E-Print Network [OSTI]

    Meckler, G.

    1986-01-01

    by distributing a small quantity (0.1 to 0.2 cfm/sq ft) of very dry, 40°F primary air. All dehumidification is handled by the ice-chilled primary air, which is distributed in variable, volume, determined by the space dehumidification requirement, to fan-coil...

  19. HUMANITIES CONFERENCE ROOMS A. Protocol for the Divisional-Assigned Conference Rooms

    E-Print Network [OSTI]

    California at Santa Cruz, University of

    HUMANITIES CONFERENCE ROOMS A. Protocol for the Divisional-Assigned Conference Rooms B. Policies & Procedures Governing Humanities Conference Rooms C. Room Descriptions D. Detailed Reservation Instructions and Form A. Protocol for the Divisional-Assigned Conference Rooms: Humanities 1: Rooms 202, 210, 402, 408

  20. Compressed Air Load Reduction Approaches and Innovations 

    E-Print Network [OSTI]

    D'Antonio, M.; Epstein, G.; Moray, S.; Schmidt, C.

    2005-01-01

    milling machine air gun 3/8 Plastic 105 3.8 Quick connect at air gun 00-836 Tool Room Sharp milling machine regulator 3/8 Rubber 105 1.3 Brass coupling-outlet of regulator 00-837 Wax Dept Assembly line- hose to air gun 1/4 Plastic 65... 1.6 Leak in air hose (taped up at leak) 00-838 Wax Dept Assembly line regulator 1/2 Copper 45 1.1 Regulator at 10' height, undertimined fitting 00-839 Wax Dept Solubles area air gun 1/2 Rubber 45 1.6 Brass coupling into air gun 45...

  1. News Room | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefieldSulfateSciTechtail.Theory ofDid you notHeatMaRIEdioxideUser Work Featured onNews ReleasesRoomNews Room

  2. Evaluation of Retrofit Variable-Speed Furnace Fan Motors

    SciTech Connect (OSTI)

    Aldrich, R.; Williamson, J.

    2014-01-01

    In conjunction with the New York State Energy Research and Development Authority (NYSERDA) and Proctor Engineering Group, Ltd. (PEG), the Consortium for Advanced Residential Buildings (CARB) has evaluated the Concept 3™ replacement motors for residential furnaces. These brushless, permanent magnet (BPM) motors can use much less electricity than their PSC (permanent split capacitor) predecessors. This evaluation focuses on existing homes in the heating-dominated climate of upstate New York with the goals of characterizing field performance and cost effectiveness. The project includes eight homes in and near Syracuse, NY. Tests and monitoring was performed both before and after fan motors were replaced. Results indicate that BPM replacement motors will be most cost effective in HVAC systems with longer run times and relatively low duct static pressures. More dramatic savings are possible if occupants use the fan-only setting when there is no thermal load. There are millions of cold-climate, U.S. homes that meet these criteria, but the savings in most homes tested in this study were modest.

  3. Cost effective combined axial fan and throttling valve control of ventilation rate

    E-Print Network [OSTI]

    Sengun, Mehmet Haluk

    Cost effective combined axial fan and throttling valve control of ventilation rate C.J. Taylor 1 P. In partic- ular, it develops a unique fan and throttling valve control system for a 22m3 test chamber, the throttling valve is employed to restrict airflow at the outlet, so generating a higher static pressure differ

  4. Inlet swirl distortion effects on the generation and propagation of fan rotor shock noise

    E-Print Network [OSTI]

    Defoe, Jeff (Jeffrey James)

    2011-01-01

    A body-force-based fan model for the prediction of multiple-pure-tone noise generation is developed in this thesis. The model eliminates the need for a full-wheel, three-dimensional unsteady RANS simulation of the fan blade ...

  5. University of Nevada Las Vegas Arduino Project Report: Fan Speed Control as a Function of Thermistor

    E-Print Network [OSTI]

    Kachroo, Pushkin

    University of Nevada Las Vegas Arduino Project Report: Fan Speed Control as a Function, and an arduino board. The arduino board is programmed to read the analog input, the thermistor, and respond by the arduino that will decrease the speed of the fan. Furthermore, if the temperature goes up, the resistance

  6. Seafloor-precipitated carbonate fans in the Neoproterozoic Rainstorm Member, Johnnie Formation, Death Valley Region, USA

    E-Print Network [OSTI]

    Fischer, Woodward

    Seafloor-precipitated carbonate fans in the Neoproterozoic Rainstorm Member, Johnnie Formation Member of the Johnnie Formation, Death Valley, USA. The fans formed in a mixed carbonate of inhibitors to carbonate nucleation (perhaps Fe2+ under anoxic conditions) likely fostered precipitation

  7. A new development in microcomputer software for mine ventilation planning involving the installation of fans

    SciTech Connect (OSTI)

    O'Leary, M.S.J.; McPherson, M.J.

    1989-01-01

    This paper introduces a computer simulation that extends the use of microcomputer systems for mine ventilation planning. The program was developed as part of an ongoing study to produce a simulation model that would determine the optimum duties of a main fan and a booster fan without requiring the trial-and-error runs that are necessary with currently available programs. To use the new program, the user specifies the location of one main fan and one booster fan, and the minimum required airflows in any number of working places. The computer determines the fan duties that maintains the required airflows at the lowest operating costs without causing undesired recirculation. The methodology of the program and an example showing how it can be applied are presented.

  8. Statistic inversion of multi-zone transition probability models for aquifer characterization in alluvial fans

    E-Print Network [OSTI]

    Zhu, Lin; Gong, Huili; Gable, Carl; Teatini, Pietro

    2015-01-01

    Understanding the heterogeneity arising from the complex architecture of sedimentary sequences in alluvial fans is challenging. This paper develops a statistical inverse framework in a multi-zone transition probability approach for characterizing the heterogeneity in alluvial fans. An analytical solution of the transition probability matrix is used to define the statistical relationships among different hydrofacies and their mean lengths, integral scales, and volumetric proportions. A statistical inversion is conducted to identify the multi-zone transition probability models and estimate the optimal statistical parameters using the modified Gauss-Newton-Levenberg-Marquardt method. The Jacobian matrix is computed by the sensitivity equation method, which results in an accurate inverse solution with quantification of parameter uncertainty. We use the Chaobai River alluvial fan in the Beijing Plain, China, as an example for elucidating the methodology of alluvial fan characterization. The alluvial fan is divided...

  9. Library Reserved Room Policy All Meeting Spaces

    E-Print Network [OSTI]

    McConnell, Terry

    to the walls or doors of the room or Library public areas without explicit permission from the Library. AllLibrary Reserved Room Policy All Meeting Spaces Room reservation To make a reservation for any Library meeting space, complete the room reservation form at http://library

  10. Fans For Greenhouses1 D. E. Buffington, R. A. Bucklin, R. W. Henley and D. B. McConnell2

    E-Print Network [OSTI]

    Hill, Jeffrey E.

    AE12 Fans For Greenhouses1 D. E. Buffington, R. A. Bucklin, R. W. Henley and D. B. McConnell2 1 drying applications. The propeller fan is the most common fan used for ventilation in greenhouses For Greenhouses In equatio

  11. Improving Control of a Dual-Duct Single-Fan Variable Air Volume Systems 

    E-Print Network [OSTI]

    Wei, G.; Martinez, J.; Minihan, T.; Brundidge, T.; Claridge, D. E.; Turner, W. D.

    2003-01-01

    pressure) can be used to fine-tune the deck temperature set points, therefore compensating for any non-ideal deck temperature reset schedules as a result of either modeling limitation/error or sensor faults. Resetting the deck temperatures...

  12. Feasibility Study: Ductless Hydronic Distribution Systems with Fan Coil Delivery

    SciTech Connect (OSTI)

    Springer, D.; Dakin, B.; Backman, C.

    2012-07-01

    The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers with a focus on ductless hydronic delivery systems that utilize water-to-air terminal units in each zone. Results indicate that annual heating and cooling energy use can be reduced by up to 27% assuming replacement of the conventional 13 SEER heat pump and coil with a similarly rated air-to-water heat pump.

  13. Direct-Expansion Air-Conditioning System Performance in Low Humidity Applications: A Case Study 

    E-Print Network [OSTI]

    Khattar, M. K.; Keebaugh, D.

    1987-01-01

    . Historic energy-use data and field-measured performance data are analyzed. The importance of certain design and operating parameters such as indoor airflow quantity, cooling coil apparatus dew-point temperature and the air-handling unit's fan operating...

  14. INFLUENCE OF DESIGN AND OPERATING CONDITIONS ON UNDERFLOOR AIR DISTRIBUTION (UFAD) SYSTEM PERFORMANCE

    E-Print Network [OSTI]

    2012-01-01

    with thermal decay and stratification. The development ofUFAD systems, room air stratification and thermal decay (Leeno thermal decay) UF – Increased stratification + common

  15. AirUCI Summer Training Workshop in Environmental

    E-Print Network [OSTI]

    Nizkorodov, Sergey

    of Catalytic Converters to Reduce Air Pollution NOx PC Lab: Air PSE (Problem Solving Environment) PSE PC Lab - Ability of catalytic converters to reduce air pollution - Laser­Induced Breakdown Spectroscopy (LIBS to 10 am: Room Rowland Hall 390 · Lecture by Prof. Sergey Nizkorodov - The use of light in analytical

  16. The Live Room : transducing resonant architectures

    E-Print Network [OSTI]

    Bain, Mark, 1966-

    1998-01-01

    The Live Room is a temporary site specific installation presented in building N 51, room 117 on the MIT campus on May 7, 1998 and concluded on June 10, 1998. Using small acoustic intensifying equipment which mount directly ...

  17. Energy Integration Visualization Room (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2012-08-01

    This two-page fact sheet describes the new Energy Integration Visualization Room in the ESIF and talks about some of the capabilities and unique visualization features of the the room.

  18. fan blades Karr, O.F.; Brooks, J.B.; Seay, E. 20 FOSSIL-FUELED...

    Office of Scientific and Technical Information (OSTI)

    draft fan blades Karr, O.F.; Brooks, J.B.; Seay, E. 20 FOSSIL-FUELED POWER PLANTS; 32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION; 42 ENGINEERING NOT INCLUDED IN OTHER...

  19. Shut Down Fans, Save $1/4 Million/Yr and Increase Airflow? 

    E-Print Network [OSTI]

    Martin, V.; Ohrt, H.

    1998-01-01

    In 1994, the fume collection system for the Desulphurization Station at Dofasco Inc., Hamilton, Ontario was studied for energy and maintenance optimization. The existing system consisted of two 600 hp fans on a wet scrubber system for two collection...

  20. Flexibility of Commercial Building HVAC Fan as Ancillary Service for Smart Grid

    E-Print Network [OSTI]

    Maasoumy, Mehdi

    2013-01-01

    controlled loads for ancillary services,” in Proc. PSCC,P. Barooah, and S. Meyn, “Ancillary service for the grid viaBuilding HVAC Fan as Ancillary Service for Smart Grid Mehdi

  1. Income Tax Deduction for Solar-Powered Roof Vents or Fans

    Broader source: Energy.gov [DOE]

    The taxpayer must provide proof of the taxpayer’s costs for installation of a solar powered roof vent or fan and a list of the persons or corporations that supplied labor or materials for the solar...

  2. Nanostructured photon management for high performance solar cells Jia Zhu, Zongfu Yu, Shanhui Fan, Yi Cui *

    E-Print Network [OSTI]

    Cui, Yi

    research efforts for renewable energy technologies. Solar cells, which harvest energy directly fromNanostructured photon management for high performance solar cells Jia Zhu, Zongfu Yu, Shanhui FanCullough Building 343, Stanford, CA 94305, USA Contents 1. Introduction

  3. Performance characteristics of a low pressure cyclone for axial-flow fan exhausts 

    E-Print Network [OSTI]

    Simpson, Shay Lynn

    1996-01-01

    on axial-flow fan exhausts to significantly reduce particulate emissions. Average emission concentrations, cut-point diameters, PMIO emission concentrations, and fractional efficiencies from this cyclone operating at different cyclone inlet velocities...

  4. Fan System Optimization Improves Production and Saves Energy at Ash Grove Cement Plant

    SciTech Connect (OSTI)

    2002-05-01

    This case study describes an optimization project implemented on a fan system at Ash Grove Cement Company, which led to annual energy and maintenance savings of $16,000 and 175,000 kilowatt-hours (kWh).

  5. Group Study Room Policy and Reservation Form

    E-Print Network [OSTI]

    Reynolds, Albert C.

    a maximum of eight (8) members. · The Group Study Room is not intended for use by scheduled classes. GroupGroup Study Room Policy and Reservation Form Please read the entire policy document below before going to the link at the end to make your reservation for the Group Study Room. Overview Mc

  6. Building Automation and Controls Systems: Integrated Room Control for Personalized Comfort and Increased ROI 

    E-Print Network [OSTI]

    Gill, D.

    2014-01-01

    Configurations ? Summary ESL-IC-14-09-05 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Room Control – System Fundamentals ? HVAC ? Terminal units ? Temperature and air flow control..., September 14-17, 2014 The Solution? ESL-IC-14-09-05 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Smart Room Control ? End-to-end system for the control of HVAC room terminal...

  7. Interpreting Soap Operas and Creating Community: Inside a Computer-Mediated Fan Culture

    E-Print Network [OSTI]

    Baym, Nancy K.

    1993-11-01

    document contains the author’s accepted manuscript. For the publisher’s version, see the link in the header of this document.] Interpreting Soap Operas and Creating Community: Inside a Computer–Mediated Fan Culture Nancy K. Baym Visiting.... K. (1993). Interpreting Soap Operas and Creating Community: Inside a Computer-Mediated Fan Culture. Journal of Folklore Research, Vol. 30(2/3), 143-176. Baym, N. K. (1993). Interpreting Soap Operas and Creating Community: Inside a Computer...

  8. Generation of fan-states of radiation field in a cavity

    E-Print Network [OSTI]

    Nguyen Ba An; Truong Minh Duc

    2001-11-30

    A scheme of generating recently introduced fan-states | \\alpha, 2k>_F (\\alpha is complex, k=1,2,3,...) is proposed basing on a \\Lambda-type atom-cavity field interaction. We show that with suitable atomic preparations and measurements a passage of a sequence of N atoms through a cavity may transform an initial field coherent state | \\alpha> to a fan-state | \\alpha, 2k>_F with k=2^{N-2}.

  9. Influence of Air Conditioner Operation on Electricity Use and Peak Demand 

    E-Print Network [OSTI]

    McGarity, A. E.; Feuermann, D.; Kempton, W.; Norford, L. K.

    1987-01-01

    Electricity demand due to occupant controlled room air conditioners in a large mater-metered apartment building is analyzed. Hourly data on the electric demand of the building and of individual air conditioners are used in analyses of annual...

  10. Analysis of Cold Air Distribution System in an Office Building by the Numerical Simulation Method 

    E-Print Network [OSTI]

    Jian, Y.; Li, D.; Xu, H.; Ma, X.

    2006-01-01

    Numerical simulation is carried out in this paper to calculate indoor air patterns, which include angles of inlet direction and induced ratios in a typical official room. According to the simulation results, the indoor air distribution and indoor...

  11. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    SciTech Connect (OSTI)

    Rudd, A.; Bergey, D.

    2014-02-01

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  12. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    SciTech Connect (OSTI)

    Rudd, Armin; Bergey, Daniel

    2014-02-01

    In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  13. Heating remote rooms in passive solar buildings

    SciTech Connect (OSTI)

    Balcomb, J.D.

    1981-01-01

    Remote rooms can be effectively heated by convection through a connecting doorway. A simple steady-state equation is developed for design purposes. Validation of a dynamic model is achieved using data obtained over a 13-day period. Dynamic effects are investigated using a simulation analysis for three different cases of driving temperature; the effect is to reduce the temperature difference between the driving room and the remote room compared to the steady-state model. For large temperature swings in the driving room a strategy which uses the intervening door in a diode mode is effective. The importance of heat-storing mass in the remote room is investigated.

  14. ENVIRONMENTAL ROOMS & WALK-IN FREEZERS SAFE WORK PRACTICES Uses: Environmental rooms are designed to control

    E-Print Network [OSTI]

    Jia, Songtao

    ENVIRONMENTAL ROOMS & WALK-IN FREEZERS ­ SAFE WORK PRACTICES Uses: Environmental rooms are designed chemistry and biology. Ventilation: Environmental rooms typically have a closed circulation system, which. Therefore, the contained atmosphere of an environmental room poses considerable safety concerns. A hazardous

  15. Energy performance of air distribution systems part II: room air stratification full scale testing

    E-Print Network [OSTI]

    Webster, Tom; Lukaschek, Wolfgang; Dickeroff, Darryl; Bauman, Fred

    2007-01-01

    Load components and solar) one at a time to determine impactto calibrate the solar gain term for one and two bank solarour testing to one setpoint, two solar load conditions with

  16. Energy performance of air distribution systems part II: room air stratification full scale testing

    E-Print Network [OSTI]

    Webster, Tom; Lukaschek, Wolfgang; Dickeroff, Darryl; Bauman, Fred

    2007-01-01

    Diffuser Design Ratio (DDR) – This refers to the ratio ofdiffusers to maintain the same DDR). In some chart legendsnumber of diffusers, airflow, DDR and extraction rate. The

  17. Energy performance of air distribution systems part II: room air stratification full scale testing

    E-Print Network [OSTI]

    Webster, Tom; Lukaschek, Wolfgang; Dickeroff, Darryl; Bauman, Fred

    2007-01-01

    and M. Shi, 2002. “Thermal Stratification Performance ofthermal plume is different than for internal loads, the stratificationstratification performance of UFAD systems under cooling operation is based on the interaction between warm thermal

  18. Air Leaks in Unexpected Places | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    National Renewable Energy Laboratory What does this mean for me? Don't waste money heating a room with air leaks, learn how to identify and seal them up tight One of the...

  19. Heat transfer pathways in underfloor air distribution (UFAD) systems

    E-Print Network [OSTI]

    Bauman, F.; Jin, H.; Webster, T.

    2006-01-01

    is little radiative heat transfer and little impact on thereturn air extrac- tion and heat transfer to the plenum. ItUFAD is often used and heat transfer out of the room through

  20. Compressed Air System Analysis and Retrofit for Energy Savings 

    E-Print Network [OSTI]

    Harding, C.; Nutter, D.

    2014-01-01

    . Therefore, high quality compressed air is a key component of that objective. The compressed air used in the manufacturing process at this facility is held to ISO (International Organization for Standardization) class 2 air quality standards.... The compressor room contained two wet storage tanks, with a total capacity of 1,800 gallons. A heated desiccant dryer with associated filters was also located in the compressor room. Dry air was sent into the plant to a 2,000 gallon dry storage tank, which...

  1. Air-to-air turbocharged air cooling versus air-to-water turbocharged air cooling

    SciTech Connect (OSTI)

    Moranne, J.-P.; Lukas, J.J.

    1984-01-01

    In Europe, turbocharged air in diesel engines used in on-road vehicles is cooled only by air. It is expected that by 1990, ten to twelve percent of European heavy trucks with diesel engines will cool turbocharged air by water. Air-to-air turbocharges air cooling is reviewed and the evolution of air-to-water turbocharged air cooling presented before the two systems are compared.

  2. Analysis of the Window Side Thermal Environment Formed by Air Barrier Technique in Winter Conditions and Its Economy 

    E-Print Network [OSTI]

    Huang, C.; Jia, Y.; Liu, L.; Wang, X.

    2006-01-01

    The air barrier technique applies airflow through a window fan to decrease the heat load of a window surface and avoid dewfall in winter and decrease heat radiation from the window surface in summer. This paper uses numerical simulation to predict...

  3. Thermal Inertia: Towards An Energy Conservation Room Management System (Technical report)

    E-Print Network [OSTI]

    Wang, Dan

    increasing attention to energy conservation around the world. The heating and air-conditioning systems, many studies are working on energy efficiency for data centers [16][17][19], a top energy consumerThermal Inertia: Towards An Energy Conservation Room Management System (Technical report) Yi Yuan

  4. Underfloor vs. overhead: a comparative analysis of air distribution systems using the EnergyPlus simulation software

    E-Print Network [OSTI]

    Daly, A.

    2006-01-01

    be able to address thermal stratification inside HVAC zones.Room Air Stratification Modeling Thermal plumes areof temperature stratification on thermal comfort in the

  5. List of Whole House Fans Incentives | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIXsource History ViewInformationWindsCompressedList of RefuelingRoomListListList of

  6. New Energy Efficiency Standards for Furnace Fans to Reduce Carbon

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformationJessework usesofPublications TheScience4.21ReviewsEarlyALSresearch40Pollution,

  7. C. CINDY FAN SELECTED MEDIA INTERVIEWS AND CONTRIBUTIONS

    E-Print Network [OSTI]

    /08/30/153513_1_1_1_1_1_1.htm 2011 "University to the World," special radio show on China Radio International, featuring UCLA on Tavis Smiley show "China ­ Roundtable" (first aired July 15, 2011) http://www.pbs.org/wnet/tavissmiley/interviews/china-%E2%80%93-roundtable/ Companion commentary to the Tavis Smiley show (July 15): "The China Stories You

  8. A partial linguistic analysis of the dialectal poetry of Rudyard Kipling: a study of Barrack-Room Ballads. 

    E-Print Network [OSTI]

    Van Pelt, Louis Jay

    1968-01-01

    indicated, 12 Table II B "Fuzzy Wuzzy" ~tOh hh fhh ft 1 f h f ~A arent inconsistencies jlelsj $wej ('ead of( fe o-j (A J fwasn' tJ [f Ef] ome an' jyour) 'ackin' ? 1 adnrt ? 1 'air 'ended ? 1 appy 'ardly 'asn't ? 2 ' ave 'ayrick ? 1... None 'e - 17 'ead ]coffin-j fan[ Ibenighted) (WeI [would] ferne of[ then jgyberj 'ceded ? -1 'ealthy ? 1 'eathen ? 2 'eld 'elp 'em 'ere's ? 5 'ills im ls (an') 'ocked 13 Orthographic portrayal of aphesis (Knocked usj 'oiler ? 1...

  9. Building America Case Study: Air Leakage and Air Transfer Between Garage and Living Space, Waldorf, Maryland (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2014-11-01

    This research project focused on evaluation of air transfer between the garage and living space in a single-family detached home constructed by a production homebuilder in compliance with the 2009 International Residential Code and the 2009 International Energy Conservation Code. The project gathered important information about the performance of whole-building ventilation systems and garage ventilation systems as they relate to minimizing flow of contaminated air from garage to living space. A series of 25 multi-point fan pressurization tests and additional zone pressure diagnostic testing characterized the garage and house air leakage, the garage-to-house air leakage, and garage and house pressure relationships to each other and to outdoors using automated fan pressurization and pressure monitoring techniques. While the relative characteristics of this house may not represent the entire population of new construction configurations and air tightness levels (house and garage) throughout the country, the technical approach was conservative and should reasonably extend the usefulness of the results to a large spectrum of house configurations from this set of parametric tests in this one house. Based on the results of this testing, the two-step garage-to-house air leakage test protocol described above is recommended where whole-house exhaust ventilation is employed. For houses employing whole-house supply ventilation (positive pressure) or balanced ventilation (same pressure effect as the Baseline condition), adherence to the EPA Indoor airPLUS house-to-garage air sealing requirements should be sufficient to expect little to no garage-to-house air transfer.

  10. SCHOOL OF DENTISTRY TELEPHONE DIRECTORY Administration Phone Room Human Resources Phone Room

    E-Print Network [OSTI]

    Minnesota, University of

    SCHOOL OF DENTISTRY TELEPHONE DIRECTORY Administration Phone Room Human Resources Phone Room Leon Employee Administrative Support 5-5751 15-136 Janet Campanaro Administrative Support, PASS 5-6950 15

  11. Minimizing Mould Growth in Cold Rooms Why does mould growth occur in Cold Rooms?

    E-Print Network [OSTI]

    Chan, Hue Sun

    , textiles, or other porous materials inside the cold room. Styrofoam is okay. Store files in plastic bins

  12. Los Alamos test-room results

    SciTech Connect (OSTI)

    McFarland, R.D.; Balcomb, J.D.

    1982-01-01

    Fourteen Los Alamos test rooms have been operated for several years; this paper covers operation during the winters of 1980-81 and 1981-82. Extensive data have been taken and computer analyzed to determine performance parameters such as efficiency, solar savings fraction, and comfort index. The rooms are directly comparable because each has the same net coefficient and solar collection area and thus the same load collector ratio. Configurations include direct gain, unvented Trombe walls, water walls, phase change walls, and two sunspace geometries. Strategies for reducing heat loss include selective surfaces, two brands of superglazing windows, a heat pipe system, and convection-suppression baffles. Significant differences in both backup heat and comfort are observed among the various rooms. The results are useful, not only for direct room-to-room comparisons, but also to provide data for validation of computer simulation programs.

  13. Portable solar heater

    SciTech Connect (OSTI)

    Kilar, L.J.

    1981-08-18

    A portable solar heater combines a self-contained hot air and heat storage system having a collector area with adjustable reflectors in a unit that can be moved from room to room as needed. The heater has fans for circulation of the solar heater air and provides both direct and indirect heat transfer to the ambient room air.

  14. ISSUANCE 2015-08-21: Energy Efficiency Program for Commercial and Industrial Equipment: Notice of Open Meetings for the Fans and Blowers Working Group

    Broader source: Energy.gov [DOE]

    Energy Efficiency Program for Commercial and Industrial Equipment: Notice of Open Meetings for the Fans and Blowers Working Group

  15. Integrated Technology Air Cleaners (ITAC): Design and Evaluation

    SciTech Connect (OSTI)

    Fisk, William J.; Cohn, Sebastian; Destaillats, Hugo; Henzel, Victor; Sidheswaran, Meera; Sullivan, Douglas P.

    2013-09-13

    The primary objective of this project was to design, build, and test an air cleaner for residential use with the potential to substantially improve indoor air quality, or maintain indoor air quality unchanged, when outdoor air ventilation rates are reduced to save energy. Two air cleaners were designed and fabricated. The design targets for airflow rate, fan power, and projected cost were met. In short term laboratory studies, both units performed as expected; however, during field studies in homes, the formaldehyde removal performance of the air cleaners was much lower than expected. In subsequent laboratory studies, incomplete decomposition of some indoor air volatile organic compounds, with formaldehyde as a product of partial decomposition of volatile organic compounds, was confirmed as the explanation for the poor formaldehyde removal performance in the field studies. The amount of formaldehyde produced per unit of decomposition of other volatile organic compounds was substantially diminished by increasing the amount of catalyst on the filter and also by decreasing the air velocity. Together, these two measures reduced formaldehyde production, per unit destruction of other volatile organic compounds, by a factor of four, while increasing the removal efficiency of volatile organic compounds by a factor of 1.4. A company with a southern California office is conducting studies in conjunction with Lawrence Berkeley National Laboratory, with the goal of incorporating the ITAC catalytic air cleaning technology in their future commercial products.

  16. TAILINGS FANS AND VALLEY-SPUR CUTOFFS 869 Copyright 2004 John Wiley & Sons, Ltd. Earth Surf. Process. Landforms 29, 869882 (2004)

    E-Print Network [OSTI]

    James, L. Allan

    2004-01-01

    of natural earthfill dam spillway not prone to catastrophic failures. Tailing fans, valley-spur cutoffs Superfund cleanup site to remove mercury. Some large tailings fans dammed main channels resulting in lakesTAILINGS FANS AND VALLEY-SPUR CUTOFFS 869 Copyright © 2004 John Wiley & Sons, Ltd. Earth Surf

  17. DOE-ID FOIA Reading Room

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformation Current HAB Packet HanfordDOE Project TapsofofDoubleReading Room READING ROOM

  18. Air Distribution and Microenvironment Evaluation of a Desktop Task Conditioning System 

    E-Print Network [OSTI]

    Zheng, G.

    2006-01-01

    equation model and two equation model. At present, k-? model is mostly adopted in indoor airflow[4]. Researches[5-6] obtained reliable results from applying k-? model in numerical simulation of three dimensional airflow field of air conditioning... of the task conditioning system. Key words: task air conditioning; numerical simulation; airflow; HDG; VDG; microenvironment 1. INTRODUCTION Total-volume ventilation and air conditioning of rooms are most used at present. Rooms are used...

  19. Reduce Air Infiltration in Furnaces (English/Chinese) (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2011-10-01

    Chinese translation of the Reduce Air Infiltration in Furnaces fact sheet. Provides suggestions on how to improve furnace energy efficiency. Fuel-fired furnaces discharge combustion products through a stack or a chimney. Hot furnace gases are less dense and more buoyant than ambient air, so they rise, creating a differential pressure between the top and the bottom of the furnace. This differential, known as thermal head, is the source of a natural draft or negative pressure in furnaces and boilers. A well-designed furnace (or boiler) is built to avoid air leakage into the furnace or leakage of flue gases from the furnace to the ambient. However, with time, most furnaces develop cracks or openings around doors, joints, and hearth seals. These openings (leaks) usually appear small compared with the overall dimensions of the furnace, so they are often ignored. The negative pressure created by the natural draft (or use of an induced-draft fan) in a furnace draws cold air through the openings (leaks) and into the furnace. The cold air becomes heated to the furnace exhaust gas temperature and then exits through the flue system, wasting valuable fuel. It might also cause excessive oxidation of metals or other materials in the furnaces. The heat loss due to cold air leakage resulting from the natural draft can be estimated if you know four major parameters: (1) The furnace or flue gas temperature; (2) The vertical distance H between the opening (leak) and the point where the exhaust gases leave the furnace and its flue system (if the leak is along a vertical surface, H will be an average value); (3) The area of the leak, in square inches; and (4) The amount of operating time the furnace spends at negative pressure. Secondary parameters that affect the amount of air leakage include these: (1) The furnace firing rate; (2) The flue gas velocity through the stack or the stack cross-section area; (3) The burner operating conditions (e.g., excess air, combustion air temperature, and so on). For furnaces or boilers using an induced-draft (ID) fan, the furnace negative pressure depends on the fan performance and frictional losses between the fan inlet and the point of air leakage. In most cases, it would be necessary to measure or estimate negative pressure at the opening. The amount of air leakage, the heat lost in flue gases, and their effects on increased furnace or boiler fuel consumption can be calculated by using the equations and graphs given in Industrial Furnaces (see W. Trinks et al., below). Note that the actual heat input required to compensate for the heat loss in flue gases due to air leakage would be greater than the heat contained in the air leakage because of the effect of available heat in the furnace. For a high-temperature furnace that is not maintained properly, the fuel consumption increase due to air leakage can be as high as 10% of the fuel input.

  20. Varying-Coefficient Functional Linear Yichao Wu , Jianqing Fan and Hans-Georg Muller

    E-Print Network [OSTI]

    Müller, Hans-Georg

    Varying-Coefficient Functional Linear Regression Yichao Wu , Jianqing Fan and Hans-Georg M¨uller NCSU, Princeton University, and UC-Davis Abstract: Functional linear regression analysis aims to model arguments of the regression parameter function. This extension of the functional linear regression model

  1. Voxels on Fire Ye Zhao Xiaoming Wei Zhe Fan Arie Kaufman Hong Qin

    E-Print Network [OSTI]

    Qin, Hong

    Voxels on Fire Ye Zhao Xiaoming Wei Zhe Fan Arie Kaufman Hong Qin Center for Visual Computing a method for the animation of fire propagation and the burning consumption of objects represented as volumetric data sets. Our method uses a volumetric fire propagation model based on an enhanced distance field

  2. The Spacing of Ceiling Fans for Human Comfort in Warm Temperature Conditions 

    E-Print Network [OSTI]

    Spain, S.

    1987-01-01

    FOR HUMAN COMFORT IN WARM TEMPERATURE CONDITIONS Syd Spain, Ph.D. Research Specialist CRS Sirrine, Inc. Houston, Tx ABSTRACT Airspeed tests of a commerci a1 1 y popular 52 in. ceiling fan operating at a low speed of 155 fpm provided sufficient...

  3. Energy Conservation Program for Consumer Products: Test Procedures for Residential Furnaces Fans; Correction

    Broader source: Energy.gov [DOE]

    On January 3, 2014 the U.S. Department of Energy (DOE) published a final rule in the Federal Register that established the test procedure for residential furnace fans. Due to drafting errors, that document inadvertently removed necessary incorporation by reference material in the Code of Federal Regulations (CFR). This final rule rectifies this error by once again adding the removed material.

  4. CHANGES IN SANDSTONE DISTRIBUTIONS BETWEEN THE UPPER, MIDDLE, AND LOWER FAN IN THE ARKANSAS JACKFORK GROUP 

    E-Print Network [OSTI]

    Mack, Clayton P.

    2010-07-14

    outcrops, it is clear there is an obvious change in the sandstone percentage and distribution. The upper fan deposit has an overall sandstone percentage of approximately 77.5% and is deposited in beds that are mainly amalgamated; 10-30m thick. Sandstone...

  5. High-amplitude reflection packets (HARPs) of the Mississippi Fan, Gulf of Mexico 

    E-Print Network [OSTI]

    Francis, Jason Michael

    2000-01-01

    Examination of seismic data from the deep-water Gulf of Mexico reveals the presence of High-Amplitude Reflection Packets (HARPs). An analog study conducted by the Ocean Drilling Program Leg 155 identified and described Amazon Fan HARPs as a stacked...

  6. The Spurious Path Problem in Abstraction Gaojian Fan and Robert C. Holte

    E-Print Network [OSTI]

    Holte, Robert

    The Spurious Path Problem in Abstraction Gaojian Fan and Robert C. Holte University of Alberta, Edmonton, Alberta, Canada {gaojian, rholte}@ualberta.ca Abstract Abstraction is a powerful technique. We provide syntactical conditions under which our method can re- move state-independent spurious

  7. NATURAL HAZARDS ON ALLUVIAL FANS: THE VENEZUELA DEBRIS FLOW AND FLASH FLOOD DISASTER

    E-Print Network [OSTI]

    Eaton, L. Scott

    NATURAL HAZARDS ON ALLUVIAL FANS: THE VENEZUELA DEBRIS FLOW AND FLASH FLOOD DISASTER In December Venezuela. Rainfall on December 2-3 totaled 200 millimeters (8 inches) and was followed by a major storm, Denver, Colorado, Naples, Italy, and Vargas, Venezuela. In time scales spanning thousands of years

  8. Virtual Prototyping Examples for Automotive Industries Fan Dai, Wolfgang Felger, Thomas Fruhauf,

    E-Print Network [OSTI]

    Zachmann, Gabriel

    Virtual Prototyping Examples for Automotive Industries Fan Dai, Wolfgang Felger, Thomas Fr­ ical prototypes. In the automotive industries, CAD and CAE systems are widely used. This provides a good basis for virtual prototyping. This vision is therefore extremely interesting for automotive in

  9. Challenges and Prospects of Nanopillar-Based Solar Cells Zhiyong Fan1,2,3

    E-Print Network [OSTI]

    Javey, Ali

    ], and solar energy into electricity [20 33]. In this review article, we summarize the continuous progress own advantages and disadvantages. The device structures utilizing radial NPL junctions (i.e., coreChallenges and Prospects of Nanopillar-Based Solar Cells Zhiyong Fan1,2,3 , Daniel J. Ruebusch1

  10. 2008-601-00 ISRP FAN 1 Upper Lemhi River Acquisition 1 Narrative Preamble

    E-Print Network [OSTI]

    ­ Acquisition 2 Upper Salmon and historically a major spawning and rearing tributary for Snake River spring/summer-run tributary streams to the Lemhi River to benefit all life stages of Snake River spring/summer-run Chinook2008-601-00 ISRP FAN 1 Upper Lemhi River ­ Acquisition 1 Narrative Preamble: The Columbia Basin

  11. The Advanced Photon Source main control room

    SciTech Connect (OSTI)

    Pasky, S.

    1998-07-01

    The Advanced Photon Source at Argonne National Laboratory is a third-generation light source built in the 1990s. Like the machine itself, the Main Control Room (MCR) employs design concepts based on today`s requirements. The discussion will center on ideas used in the design of the MCR, the comfort of personnel using the design, and safety concerns integrated into the control room layout.

  12. Proposal of room-temperature diamond maser

    E-Print Network [OSTI]

    Liang Jin; Matthias Pfänder; Nabeel Aslam; Sen Yang; Jörg Wrachtrup; Ren-Bao Liu

    2015-09-25

    Lasers have revolutionized optical science and technology, but their microwave counterpart, maser, has not realized its great potential due to its demanding work conditions (high-vacuum for gas maser and liquid-helium temperature for solid-state maser). Room-temperature solid-state maser is highly desirable, but under such conditions the lifetimes of emitters (usually electron spins) are usually too short (~ns) for population inversion. The only room-temperature solid-state maser is based on a pentacene-doped p-terphenyl crystal, which has long spin lifetime (~0.1 ms). This maser, however, operates only in the pulse mode and the material is unstable. Here we propose room-temperature maser based on nitrogen-vacancy (NV) centres in diamond, which feature long spin lifetimes at room temperature (~10 ms), high optical pump efficiency, and material stability. We demonstrate that under readily accessible conditions, room-temperature diamond maser is feasible. Room-temperature diamond maser may facilitate a broad range of microwave technologies.

  13. VENDOR CONFERENCE ROOM REQUEST FORM Only One Event Per Form

    E-Print Network [OSTI]

    Brent, Roger

    VENDOR CONFERENCE ROOM REQUEST FORM Only One Event Per Form CONTACT INFORMATION Contact Name Signature ______________________________________________ (Required) REQUESTED CONFERENCE ROOM Date request for a conference room is not confirmed until you receive a confirmation from Meeting & Event

  14. Training Room Equipment Instructions Projector and TV Display

    E-Print Network [OSTI]

    Crawford, T. Daniel

    Training Room Equipment Instructions Projector and TV Display The control panel on the wall are connected to a training room computer and room is equipped with a keyboard, mouse and clicker. Connect USB

  15. The Influence of Operating Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner 

    E-Print Network [OSTI]

    Yu, J.; Yang, C.; Guo, R.; Wu, D.; Chen, H.

    2006-01-01

    mode, setting outer curtain can conserve energy for 40.9% and 20.4% compared with no curtain and inner curtain states, respectively. In winter high speed mode is the most efficient for saving energy which can decrease 40.3% and 30.9% compared with low...

  16. Theoretical Study of a Novel Control Method of VAV Air-conditioning System Based on MATLAB 

    E-Print Network [OSTI]

    Shi, Z.; Hu, S.; Wang, G.; Li, A.

    2006-01-01

    The main purpose of this study is to put forward a novel nonlinear feedback control strategy on controlling indoor air temperature by variable air volume. A dynamic model of a typical room for a VAV air-conditioning system is established...

  17. Tool Improves Electricity Demand Predictions to Make More Room...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Tool Improves Electricity Demand Predictions to Make More Room for Renewables Tool Improves Electricity Demand Predictions to Make More Room for Renewables October 3, 2011 -...

  18. Environmental effect on room-temperature ductility of isothermally forged TiAl-base alloys

    SciTech Connect (OSTI)

    Nakamura, Morihiko; Hashimoto, Kenki (National Research Inst. for Metals, Tokyo (Japan)); Itoh, Naoyuki (Nippon Steel Corp., Chiba (Japan)); Tsujimoto, Tokuzo (Ibaraki Univ. (Japan). Faculty of Engineering); Suzuki, Toshiyuki (Kougakuin Univ., Tokyo (Japan))

    1994-02-01

    Isothermally forged TiAl-base alloy (Al-rich, Mn-containing, and Cr-containing TiAl) were heat-treated in various conditions, and equiaxed grain structures consisting of [gamma] and [alpha][sub 2] or [beta] phases were obtained. The heat-treated alloys were tensile tested in vacuum and air at room temperature, and the environmental effect on tensile elongation was studied. The ductility of the alloys consisting of equiaxed [gamma] grains and a large amount of [alpha][sub 2] grains was not largely affecting by laboratory air, and a decrease in the amount of [alpha][sub 2] grains resulted in a large reduction of ductility in air. The [beta] phase in the Cr-containing alloy improved the ductility in vacuum, but it resulted in a large reduction of ductility in air.

  19. High efficiency novel window air conditioner

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Bansal, Pradeep

    2015-07-24

    This paper presents the technical development of a high efficiency window air conditioner. In order to achieve higher energy efficiency ratio (EER), the original capacity of the R410A unit was downgraded by replacing the original compressor with a lower capacity but higher EER compressor, while all heat exchangers and the chassis from the original unit were retained. The other subsequent major modifications included – the AC fan motor being replaced with a brushless high efficiency electronically commuted motor (ECM) motor, the capillary tube being replaced with a needle valve to better control the refrigerant flow and refrigerant set points, andmore »R410A being replaced with drop-in environmentally friendly binary mixture of R32 (85% molar concentration)/R125 (15% molar concentration). All these modifications resulted in significant EER enhancement of the modified unit.« less

  20. High efficiency novel window air conditioner

    SciTech Connect (OSTI)

    Bansal, Pradeep

    2015-07-24

    This paper presents the technical development of a high efficiency window air conditioner. In order to achieve higher energy efficiency ratio (EER), the original capacity of the R410A unit was downgraded by replacing the original compressor with a lower capacity but higher EER compressor, while all heat exchangers and the chassis from the original unit were retained. The other subsequent major modifications included – the AC fan motor being replaced with a brushless high efficiency electronically commuted motor (ECM) motor, the capillary tube being replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and R410A being replaced with drop-in environmentally friendly binary mixture of R32 (85% molar concentration)/R125 (15% molar concentration). All these modifications resulted in significant EER enhancement of the modified unit.

  1. Ferromagnetism at room temperature in Cr-doped anodic titanium dioxide nanotubes

    SciTech Connect (OSTI)

    Liao, Yulong E-mail: hwzhang@uestc.edu.cn; Zhang, Huaiwu E-mail: hwzhang@uestc.edu.cn; Li, Jie; Yu, Guoliang; Zhong, Zhiyong; Bai, Feiming; Jia, Lijun; Zhang, Shihong; Zhong, Peng

    2014-05-07

    This study reports the room-temperature ferromagnetism in Cr-doped TiO{sub 2} nanotubes (NTs) synthesized via the electrochemical method followed by a novel Cr-doping process. Scanning electron microscopy and transmission electron microscopy showed that the TiO{sub 2} NTs were highly ordered with length up to 26 ?m, outer diameter about 110 nm, and inner diameter about 100 nm. X-ray diffraction results indicated there were no magnetic contaminations of metallic Cr clusters or any other phases except anatase TiO{sub 2}. The Cr-doped TiO{sub 2} NTs were further annealed in oxygen, air and argon, and room-temperature ferromagnetism was observed in all Cr-doped samples. Moreover, saturation magnetizations and coercivities of the Cr-doped under various annealing atmosphere were further analyzed, and results indicate that oxygen content played a critical role in the room-temperature ferromagnetism.

  2. inAir: Measuring and Visualizing Indoor Air Quality Sunyoung Kim & Eric Paulos

    E-Print Network [OSTI]

    Paulos, Eric

    , long-term exposure to such chemicals can cause significant chronic health problems like asthma to the development of chronic respiratory diseases such as asthma, heart disease, and lung cancer. Complicating quality and are often causes of Figure 1. inAir located in a living room. dizziness, nausea, allergic

  3. Film Cooling with Forward and Backward Injection for Cylindrical and Fan-shaped Holes Using PSP Measurement Technique 

    E-Print Network [OSTI]

    Chen, Andrew F

    2013-11-08

    effectiveness distributions were obtained using the steady state pressure sensitive paint (PSP) technique. Four common film-hole geometries with forward injection were used in this study: simple angled cylindrical holes and fan-shaped holes, and compound angled...

  4. Control room habitability system review models

    SciTech Connect (OSTI)

    Gilpin, H. )

    1990-12-01

    This report provides a method of calculating control room operator doses from postulated reactor accidents and chemical spills as part of the resolution of TMI Action Plan III.D.3.4. The computer codes contained in this report use source concentrations calculated by either TACT5, FPFP, or EXTRAN, and transport them via user-defined flow rates to the control room envelope. The codes compute doses to six organs from up to 150 radionuclides (or 1 toxic chemical) for time steps as short as one second. Supporting codes written in Clipper assist in data entry and manipulation, and graphically display the results of the FORTRAN calculations. 7 refs., 22 figs.

  5. NEPA Reading Room | National Nuclear Security Administration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformationJessework usesof Energy Moving Forward tocomponentStatementsReading Room

  6. Economic Recovery of Oil Trapped at Fan Margins Using High Angle Wells and Multiple Hydraulic Fractures

    SciTech Connect (OSTI)

    Mike L. Laue

    1997-05-30

    The distal fan margin in the northeast portion of the Yowlumne field contains significant reserves but is not economical to develop using vertical wells. Numerous interbedded shales and deteriorating rock properties limit producibility. In addition, extreme depths (13,000 ft) present a challenging environment for hydraulic fracturing and artificial lift. Lastly, a mature waterflood increases risk because of the uncertainty with size and location of flood fronts. This project attempts to demonstrate the effectiveness of exploiting the distal fan margin of this slope-basin clastic reservoir through the use of a high-angle well completed with multiple hydraulic-fracture treatments. The combination of a high-angle (or horizontal) well and hydraulic fracturing will allow greater pay exposure than can be achieved with conventional vertical wells while maintaining vertical communication between thin interbedded layers and the wellbore. The equivalent production rate and reserves of three vertical wells are anticipated at one-half to two-thirds the cost.

  7. A hydrogeological evaluation of alluvial fans in northern Big Bend National Park, Texas, using geophysical methods 

    E-Print Network [OSTI]

    Archer, Jerry Alan

    1982-01-01

    additional ground-water resources. One major aspect of the 5 yr investigation is to study the hydrogeologic role of the extensive alluvial deposits. This portion of the project is aimed at determining alluvial fan morphol- ogy and bedrock topography.... Seismic Investigation Previous Work The seismic refraction technique has been used extensively in ground-water exploration, particularly when the hydrogeologic situation consists of unconsolidated sands and gravel overlying WELL IO, 4a, '2 3 ~b 4 5...

  8. A fundamentally new approach to air-cooled heat exchangers.

    SciTech Connect (OSTI)

    Koplow, Jeffrey P.

    2010-01-01

    We describe breakthrough results obtained in a feasibility study of a fundamentally new architecture for air-cooled heat exchangers. A longstanding but largely unrealized opportunity in energy efficiency concerns the performance of air-cooled heat exchangers used in air conditioners, heat pumps, and refrigeration equipment. In the case of residential air conditioners, for example, the typical performance of the air cooled heat exchangers used for condensers and evaporators is at best marginal from the standpoint the of achieving maximum the possible coefficient of performance (COP). If by some means it were possible to reduce the thermal resistance of these heat exchangers to a negligible level, a typical energy savings of order 30% could be immediately realized. It has long been known that a several-fold increase in heat exchanger size, in conjunction with the use of much higher volumetric flow rates, provides a straight-forward path to this goal but is not practical from the standpoint of real world applications. The tension in the market place between the need for energy efficiency and logistical considerations such as equipment size, cost and operating noise has resulted in a compromise that is far from ideal. This is the reason that a typical residential air conditioner exhibits significant sensitivity to reductions in fan speed and/or fouling of the heat exchanger surface. The prevailing wisdom is that little can be done to improve this situation; the 'fan-plus-finned-heat-sink' heat exchanger architecture used throughout the energy sector represents an extremely mature technology for which there is little opportunity for further optimization. But the fact remains that conventional fan-plus-finned-heat-sink technology simply doesn't work that well. Their primary physical limitation to performance (i.e. low thermal resistance) is the boundary layer of motionless air that adheres to and envelops all surfaces of the heat exchanger. Within this boundary layer region, diffusive transport is the dominant mechanism for heat transfer. The resulting thermal bottleneck largely determines the thermal resistance of the heat exchanger. No one has yet devised a practical solution to the boundary layer problem. Another longstanding problem is inevitable fouling of the heat exchanger surface over time by particulate matter and other airborne contaminants. This problem is especially important in residential air conditioner systems where often little or no preventative maintenance is practiced. The heat sink fouling problem also remains unsolved. The third major problem (alluded to earlier) concerns inadequate airflow to heat exchanger resulting from restrictions on fan noise. The air-cooled heat exchanger described here solves all of the above three problems simultaneously. The 'Air Bearing Heat Exchanger' provides a several-fold reduction in boundary layer thickness, intrinsic immunity to heat sink fouling, and drastic reductions in noise. It is also very practical from the standpoint of cost, complexity, ruggedness, etc. Successful development of this technology is also expected to have far reaching impact in the IT sector from the standpointpoint of solving the 'Thermal Brick Wall' problem (which currently limits CPU clocks speeds to {approx}3 GHz), and increasing concern about the the electrical power consumption of our nation's information technology infrastructure.

  9. Vehicle cabin cooling system for capturing and exhausting heated boundary layer air from inner surfaces of solar heated windows

    DOE Patents [OSTI]

    Farrington, Robert B. (Golden, CO); Anderson, Ren (Broomfield, CO)

    2001-01-01

    The cabin cooling system includes a cooling duct positioned proximate and above upper edges of one or more windows of a vehicle to exhaust hot air as the air is heated by inner surfaces of the windows and forms thin boundary layers of heated air adjacent the heated windows. The cabin cooling system includes at least one fan to draw the hot air into the cooling duct at a flow rate that captures the hot air in the boundary layer without capturing a significant portion of the cooler cabin interior air and to discharge the hot air at a point outside the vehicle cabin, such as the vehicle trunk. In a preferred embodiment, the cooling duct has a cross-sectional area that gradually increases from a distal point to a proximal point to the fan inlet to develop a substantially uniform pressure drop along the length of the cooling duct. Correspondingly, this cross-sectional configuration develops a uniform suction pressure and uniform flow rate at the upper edge of the window to capture the hot air in the boundary layer adjacent each window.

  10. Austin Building Conference Rooms Original Implementation: June 10, 1986

    E-Print Network [OSTI]

    Hung, I-Kuai

    Austin Building Conference Rooms Original Implementation: June 10, 1986 Last Revision: January 28 buildings, facilities, equipment, and grounds, hereafter referred to as facilities, under the control to Room 305 and Room 307 in the Austin Building. These conference rooms will be primarily for the use

  11. Determining the Right Air Quality for Your Compressed Air System...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Applications Plant Air Air tools, general plant air Instrument Air Laboratories, paint spraying, powder coating, climate control Process Air Food and pharmaceutical process...

  12. Biology Advising Office Building 44, Room 135

    E-Print Network [OSTI]

    Clayton, Dale H.

    Biology Advising Office Building 44, Room 135 Mailing Address: Biology Advising Office, University of Utah, 257 South 1400 East, Salt Lake City, Utah 84112-0840 http://www.biology.utah.edu/undergraduate/advising.php Email: advising@biology.utah.edu Phone: (801) 581-6244 Fax: (801) 581-8571 Denise M. Brenis, Director

  13. Prof. Sergiu Hart Feldman Building, room 216

    E-Print Network [OSTI]

    Hart, Sergiu

    Prof. Sergiu Hart Feldman Building, room 216 phone: 026584135 email: hart@huji.ac.il web page: http://www.ma.huji.ac.il/hart GAME THEORY BOOKS English 1. Neuman, J. von and O. Solan, and S. Zamir, Game Theory, Cambridge University Press, 2013. 12. Aumann, R. J. and S. Hart

  14. Advanced nuclear plant control room complex

    DOE Patents [OSTI]

    Scarola, Kenneth (Windsor, CT); Jamison, David S. (Windsor, CT); Manazir, Richard M. (North Canton, CT); Rescorl, Robert L. (Vernon, CT); Harmon, Daryl L. (Enfield, CT)

    1993-01-01

    An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

  15. Math Placement Office Mathematics room 108

    E-Print Network [OSTI]

    Fatkullin, Ibrahim

    Math Placement Office Mathematics room 108 TEL (520) 621-6892 FAX (520) 621-8322 www.math.arizona.edu/placement placement@math.arizona.edu INSTRUCTIONS FOR COURSE EQUIVALENCY VERIFICATION FOR MATH TRANSFER COURSES, the Math Department will determine if a transferred Mathematics course has a UA equivalent

  16. Economic Recovery of Oil Trapped at Fan Margins Using Hig Angle Wells Multiple Hydraulic Fractures

    SciTech Connect (OSTI)

    Laue, M.L.

    1997-11-21

    The Yowlumne field is a giant field in the southern San Joaquin basin, Kern County, California. It is a deep (13,000 ft) waterflood operation that produces from the Miocene- aged Stevens Sand. The reservoir is interpreted as a layered, fan-shaped, prograding turbidite complex containing several lobe-shaped sand bodies that represent distinct flow units. A high ultimate recovery factor is expected, yet significant quantities of undrained oil remain at the fan margins. The fan margins are not economic to develop using vertical wells because of thinning pay, deteriorating rock quality, and depth. This project attempts to demonstrate the effectiveness of exploiting the northeast distal fan margin through the use of a high- angle well completed with multiple hydraulic- fracture treatments. A high-angle well offers greater pay exposure than can be achieved with a vertical well. Hydraulic-fracture treatments will establish vertical communication between thin interbedded layers and the wellbore. The equivalent production rate and reserves of three vertical wells are anticipated at a cost of approximately two vertical wells. The near-horizontal well penetrated the Yowlumne sand; a Stevens sand equivalent, in the distal fan margin in the northeast area of the field. The well was drilled in a predominately westerly direction towards the interior of the field, in the direction of improving rock quality. Drilling and completion operations proved to be very challenging, leading to a number of adjustments to original plans. Hole conditions resulted in obtaining less core material than desired and setting intermediate casing 1200 ft too high. The 7 in. production liner stuck 1000 ft off bottom, requiring a 5 in. liner to be run the rest of the way. The cement job on the 5 in. liner resulted in a very poor bond, which precluded one of three hydraulic fracture treatments originally planned for the well. Openhole logs confirmed most expectations going into the project about basic rock properties: the formation was shaly with low porosities, and water saturations were in line with expectations, including the presence of some intervals swept out by the waterflood. High water saturations at the bottom of the well eliminated one of the originally planned hydraulic fracture treatments. Although porosities proved to be low, they were more uniform across the formation than expected. Permeabilities of the various intervals continue to be evaluated, but appear to be better than expected from the porosity log model derived in Budget Period One. The well was perforated in all pay sections behind the 5 in. liner. Production rates and phases agree nicely with log calculations, fractional flow calculations, and an analytical technique used to predict the rate performance of the well.

  17. Building 13 Conference Room Policy Building 13 conference rooms are available for use by the members of the MIT

    E-Print Network [OSTI]

    Kastner, Marc A.

    Building 13 Conference Room Policy Building 13 conference rooms are available for Materials Science and Engineering. Reservations for building 13 conference rooms and keys, if needed, are made through the following building 13 offices: 1. von Hippel Room (13-2137) ­ CMSE headquarters staff

  18. Ventilation Air Preconditioning Systems 

    E-Print Network [OSTI]

    Khattar, M.; Brandemuehl, M. J.

    1996-01-01

    Increased outside ventilation air requirements demand special attention to how that air will be conditioned. In winter, the incoming air may need preheating; in summer. the mixed air may be too humid for effective dehumidification. Part...

  19. Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration

    E-Print Network [OSTI]

    Grimsrud, David T.

    2009-01-01

    to mount the passive samplers in a house. designed describedhouses screened for study List of Figures A.l A.2 A.3 A.4 PassivePassive Sampler Sampler Girman/Allen Girman/Allen Wednesday 16 November Test house (

  20. Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration

    E-Print Network [OSTI]

    Grimsrud, David T.

    2009-01-01

    sponsored by Bonneville Power Administration under ContractReport prepared for Bonneville Power Administration, #85544.Report to Bonneville Power Administration D.T. Grimsrud,

  1. Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration

    E-Print Network [OSTI]

    Grimsrud, David T.

    2009-01-01

    by Bonneville Power Administration under Contract No. DE-for Bonneville Power Administration, #85544. Jardinier, P. (to Bonneville Power Administration D.T. Grimsrud, September

  2. Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration

    E-Print Network [OSTI]

    Grimsrud, David T.

    2009-01-01

    Version of Infiltration Calculation Training Course Study A-Quality Study, the effects of house tightening infiltrationfield studies begin to demonstrate the low infiltration

  3. Optimal Terminal Box Control for Single Duct Air-Handling Units 

    E-Print Network [OSTI]

    Cho, Y.; Vondal, J.; Wang, G.; Liu, M.

    2006-01-01

    Terminal boxes maintain room temperature by modulating supply air temperature and airflow in building HVAC systems. Terminal boxes with conventional control sequences often supply inadequate airflow to a conditioned space, resulting in occupant...

  4. Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems

    E-Print Network [OSTI]

    Wetter, Michael

    2010-01-01

    Austria, September 2006. Modelica As- sociation and Arsenalsystems. The ?exibility of Modelica has been T room in [° C]lss. AirConditioning - a Modelica li- o brary for dynamic

  5. Air Quality

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 OutreachProductswsicloudwsiclouddenDVA N C E D B L O O D S TA I N P A T T E R N AManaged bynuevo sistemaAir

  6. What Problems can be Encountered when Efficiency Upgrades are Made to Fans and what Should the Approach be to Address Those Problems 

    E-Print Network [OSTI]

    Martin, V.

    2015-01-01

    : What Problems May be encountered? What Approach Best Addresses Them? Presented by Vern Martin, P.Eng. FLOWCARE Engineering Inc. IETC 2015 June 2 - 4 New Orleans, LA ESL-IE-15-06-39 Proceedings of the Thrity-Seventh Industrial Energy Technology... Conference New Orleans, LA. June 2-4, 2015 Site performance testing to rigorous standards is required to establish fan efficiency. Causes of Poor Fan Efficiency Issues to investigate: • Was the fan efficiency overstated? • Was there a better choice...

  7. Energy Efficiency Indicators Methodology Booklet

    E-Print Network [OSTI]

    Sathaye, Jayant

    2010-01-01

    source) District heating Wood Biogas Charcoal Stove/ RoomHeating Television Refrigerator Freezer Washing Machine Air-Conditioner Fan Tubular fluorescent Compact fluorescent Halogen Kerosene lamp Wood Stove Biogas

  8. Air Movers of the Eighties 

    E-Print Network [OSTI]

    Miller, G.

    1985-01-01

    Expensive fan wrecks and down time occurs when couplings break or gearboxes self-destruct. A viable alternative eliminates shaft, coupling, and gearbox moving motor to ground level, driving a hydraulic pump transmitting fluid under pressure. A...

  9. Strategy for the Operation of Cooling Towers with variable Speed Fans

    E-Print Network [OSTI]

    Iñigo-Golfín, J

    2001-01-01

    Within the SPS Cooling Water Project at CERN aimed at the reduction of water consumption, this primary open cooling loop will be closed and all the primary cooling circuit components will be upgraded to the new required duty and brought to the necessary safety and operability standards. In particular the tower fans will be fitted with variable frequency drives to replace the existing two speed motors. This paper presents a study to optimize the operation of SPS cooling towers taking into account outdoor conditions (wet and dry bulb temperatures) and the entirety of the primary circuit in which they will operate.

  10. 2015-03-26 Issuance: Fans and Blowers ASRAC Working Group; Notice of Intent

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t y A s s iof1 of 8 2 of 8of| Department of Energy Fans

  11. DEPARTMENT OF MECHANICAL ENGINEERING Room and Projector Booking Procedures

    E-Print Network [OSTI]

    Haykin, Simon

    DEPARTMENT OF MECHANICAL ENGINEERING Room and Projector Booking Procedures September 1, 2011 Due within the Department of Mechanical Engineering. General: The Department of Mechanical Engineering has. Mechanical Engineering faculty, staff, and graduate students may book the rooms directly by visiting

  12. Metal-Air Batteries

    SciTech Connect (OSTI)

    Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

    2011-08-01

    Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

  13. TA1 Room Layout with Newport Laser

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservationBio-Inspired Solar Fuel Production 1:PhysicsSyndicated Contentwo major

  14. News Room | Princeton Plasma Physics Lab

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefieldSulfateSciTechtail.Theory ofDid you notHeatMaRIEdioxideUser Work Featured onNews ReleasesRoomNews

  15. Electronic FOIA Reading Room - Hanford Site

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room NewsInformation Current HABFES Science NetworkMediatorElectrocatalystsElectron-StateFreedom

  16. Room Temperature Dispenser Photocathode Using Elemental Cesium

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power AdministrationRobust, High-Throughput Analysis of Protein Structures PrintRooftop DiagnosticianRoom Temperature

  17. Reading Room | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of NaturalDukeWakefield Municipal GasAdministration Medal01 Sandia4)9 Federal Register / Vol. 76,EXAMPLE 4Reading Room |

  18. Evaluation of Station Post Porcelain Insulators with Room Temperature

    E-Print Network [OSTI]

    Evaluation of Station Post Porcelain Insulators with Room Temperature Vulcanized (RTV) Silicone to Engineer the Future Electric Energy System #12;Evaluation of Station Post Porcelain Insulators with Room and analysis of porcelain post insulators that were coated with a room temperature vulcanized (RTV) silicone

  19. Air temperature thresholds for indoor comfort and perceived air quality

    E-Print Network [OSTI]

    Zhang, Hui; Edward, Arens; Pasut, Wilmer

    2012-01-01

    in the Netherlands, Indoor Air 2, 127 – 136. BuildingPaliaga, G. (2009) Moving air for comfort. ASHRAE Journal,ventilation system on perceived air quality, Indoor Air

  20. Observations of supra-arcade fans: instabilities at the head of reconnection jets

    SciTech Connect (OSTI)

    Innes, D. E.; Guo, L.-J.; Schmit, D.; Bhattacharjee, A.; Huang, Y.-M.

    2014-11-20

    Supra-arcade fans are bright, irregular regions of emission that develop during eruptive flares above flare arcades. The underlying flare arcades are thought to be a consequence of magnetic reconnection along a current sheet in the corona. At the same time, theory predicts plasma jets from the reconnection sites which are extremely difficult to observe directly because of their low densities. It has been suggested that the dark supra-arcade downflows (SADs) seen falling through supra-arcade fans may be low-density jet plasma. The head of a low-density jet directed toward higher-density plasma would be Rayleigh-Taylor unstable, and lead to the development of rapidly growing low- and high-density fingers along the interface. Using Solar Dynamics Observatory/Atmospheric Imaging Assembly 131 Å images, we show details of SADs seen from three different orientations with respect to the flare arcade and current sheet, and highlight features that have been previously unexplained, such as the splitting of SADs at their heads, but are a natural consequence of instabilities above the arcade. Comparison with three-dimensional magnetohydrodynamic simulations suggests that SADs are the result of secondary instabilities of the Rayleigh-Taylor type in the exhaust of reconnection jets.

  1. Web-based Support Systems for Sustainable Communities W.N. Liu J.T. Yao L. Fan Y.Y. Yao X.D. Yang

    E-Print Network [OSTI]

    Yao, JingTao

    present an architecture of Web-based support systems for sustainable communities. The architectureWeb-based Support Systems for Sustainable Communities W.N. Liu J.T. Yao L. Fan Y.Y. Yao X.D. Yang,fan,yyao,yang}@cs.uregina.ca ABSTRACT This paper studies Web-based support systems for sustain- able communities. A sustainable

  2. Cu-Cu direct bonding achieved by surface method at room temperature

    SciTech Connect (OSTI)

    Utsumi, Jun [Advanced Technology Research Center, Mitsubishi Heavy Industries, Ltd., 1-8-1 Sachiura, Kanazawa-ku, Yokohama 236-8515 (Japan); Ichiyanagi, Yuko, E-mail: yuko@ynu.ac.jp [Department of Physics, Graduate School of Engineering, Yokohama National University, Tokiwadai, Hodogaya, Yokohama 240-8501 (Japan)

    2014-02-20

    The metal bonding is a key technology in the processes for the microelectromechanical systems (MEMS) devices and the semiconductor devices to improve functionality and higher density integration. Strong adhesion between surfaces at the atomic level is crucial; however, it is difficult to achieve close bonding in such a system. Cu films were deposited on Si substrates by vacuum deposition, and then, two Cu films were bonded directly by means of surface activated bonding (SAB) at room temperature. The two Cu films, with the surface roughness Ra about 1.3nm, were bonded by using SAB at room temperature, however, the bonding strength was very weak in this method. In order to improve the bonding strength between the Cu films, samples were annealed at low temperatures, between 323 and 473 K, in air. As the result, the Cu-Cu bonding strength was 10 times higher than that of the original samples without annealing.

  3. Moving air for comfort

    E-Print Network [OSTI]

    Arens, Edward; Turner, Stephen; Zhang, Hui; Paliaga, Gwelen

    2009-01-01

    Brager, L. Zagreus. 2007, “Air movement preferences observed709-731. 9. Toftum, J. 2004. “Air movement – good or bad? ”Indoor Air 14, pp 40-45. 10. Gong, N. , K. Tham, A. Melikov,

  4. Feasibility of air capture

    E-Print Network [OSTI]

    Ranjan, Manya

    2010-01-01

    Capturing CO2 from air, referred to as Air Capture, is being proposed as a viable climate change mitigation technology. The two major benefits of air capture, reported in literature, are that it allows us to reduce the ...

  5. Stress, performance, and control room operations

    SciTech Connect (OSTI)

    Fontaine, C.W.

    1990-01-01

    The notion of control room operator performance being detrimentally affected by stress has long been the focus of considerable conjecture. It is important to gain a better understanding of the validity of this concern for the development of effective severe-accident management approaches. This paper illustrates the undeniable negative impact of stress on a wide variety of tasks. A computer-controlled simulated work environment was designed in which both male and female operators were closely monitored during the course of the study for both stress level (using the excretion of the urine catecholamines epinephrine and norepinephrine as an index) and job performance. The experimental parameters employed by the study when coupled with the subsequent statistical analyses of the results allow one to make some rather striking comments with respect to how a given operator might respond to a situation that he or she perceives to be psychologically stressful (whether the stress be externally or internally generated). The findings of this study clearly indicated that stress does impact operator performance on tasks similar in nature to those conducted by control room operators and hence should be seriously considered in the development of severe-accident management strategies.

  6. AirUCI Summer Institute 2011 Schedule Monday, June 27

    E-Print Network [OSTI]

    Nizkorodov, Sergey

    / mouthwash measured by FTIR - Ability of catalytic converters to reduce air pollution - Laser. Sergey Nizkorodov - The use of light in analytical chemistry - Absorption of light and Beer's Law (p. 30 Wednesday, June 29 9 am to 11 am: Room Rowland Hall 390 · Lecture by Prof. Barbara Finlayson­Pitts - Light

  7. Primary zone air proportioner

    DOE Patents [OSTI]

    Cleary, Edward N. G. (San Diego, CA)

    1982-10-12

    An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

  8. Biological Air Emissions Control

    Office of Energy Efficiency and Renewable Energy (EERE)

    Air quality standards are becoming more stringent for the U.S. wood products industry. Emissions of volatile organic compounds (VOCs) and hazardous air pollutants (HAPs) (including methanol,...

  9. Chapter 21 Air Quality

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    are in the PortlandVancouver metro area where there are more industrial sources of air pollution and higher levels of traffic congestion that create more air emissions....

  10. y 1000km of high resolution sleeve-gun array transects on the North Sza Fan, located at tbe mouth orwegian Channel, reveal three domina tyles of sedimentation within a thick

    E-Print Network [OSTI]

    y 1000km of high resolution sleeve-gun array transects on the North Sza Fan, located at tbe mouth the lution data across the fan other than conventional he seismic source was an arra nstruments 40 in3 sleeve-guns along the fan axis. These data were shot with the same sleeve-gun array but recorded digitally via a 144

  11. Absorber Materials at Room and Cryogenic Temperatures

    SciTech Connect (OSTI)

    F. Marhauser, T.S. Elliott, A.T. Wu, E.P. Chojnacki, E. Savrun

    2011-09-01

    We recently reported on investigations of RF absorber materials at cryogenic temperatures conducted at Jefferson Laboratory (JLab). The work was initiated to find a replacement material for the 2 Kelvin low power waveguide Higher Order Mode (HOM) absorbers employed within the original cavity cryomodules of the Continuous Electron Beam Accelerator Facility (CEBAF). This effort eventually led to suitable candidates as reported in this paper. Furthermore, though constrained by small funds for labor and resources, we have analyzed a variety of lossy ceramic materials, several of which could be usable as HOM absorbers for both normal conducting and superconducting RF structures, e.g. as loads in cavity waveguides and beam tubes either at room or cryogenic temperatures and, depending on cooling measures, low to high operational power levels.

  12. Influence of Fault and Optimization of PID Parameters in Building Air-Conditioning System 

    E-Print Network [OSTI]

    Kuniyoshi, K.; Akashi, Y.; Sumiyoshi, D.; Song, Y.

    2005-01-01

    [s] APPROPRIATE 1 30 FAULT 20 30 Table 2. PID Parameters Of VWV 2-way Valve For Experiment Figure 5. Experiment Results 0 5 10 15 20 25 (a)Outside & room temp. Te m p. [d eg .C ] 10 20 30 40 500 60 Elapsed time[min] Room... opening deg.(fault case) 10 20 30 40 50 60 Elapsed time[min] 30 35 40 (c)Supply air temp. Te m p. [d eg .C ] 0 Supply air temp.(appropriate case) Supply air temp.(fault case) 10 20 30 40 50 60 Elapsed time[min] 0 20 40 60 80 100 (d...

  13. Robustness analysis of an air heating plant and control law by using polynomial chaos

    SciTech Connect (OSTI)

    Colón, Diego; Ferreira, Murillo A. S.; Bueno, Átila M.; Balthazar, José M.; Rosa, Suélia S. R. F. de

    2014-12-10

    This paper presents a robustness analysis of an air heating plant with a multivariable closed-loop control law by using the polynomial chaos methodology (MPC). The plant consists of a PVC tube with a fan in the air input (that forces the air through the tube) and a mass flux sensor in the output. A heating resistance warms the air as it flows inside the tube, and a thermo-couple sensor measures the air temperature. The plant has thus two inputs (the fan's rotation intensity and heat generated by the resistance, both measured in percent of the maximum value) and two outputs (air temperature and air mass flux, also in percent of the maximal value). The mathematical model is obtained by System Identification techniques. The mass flux sensor, which is nonlinear, is linearized and the delays in the transfer functions are properly approximated by non-minimum phase transfer functions. The resulting model is transformed to a state-space model, which is used for control design purposes. The multivariable robust control design techniques used is the LQG/LTR, and the controllers are validated in simulation software and in the real plant. Finally, the MPC is applied by considering some of the system's parameters as random variables (one at a time, and the system's stochastic differential equations are solved by expanding the solution (a stochastic process) in an orthogonal basis of polynomial functions of the basic random variables. This method transforms the stochastic equations in a set of deterministic differential equations, which can be solved by traditional numerical methods (That is the MPC). Statistical data for the system (like expected values and variances) are then calculated. The effects of randomness in the parameters are evaluated in the open-loop and closed-loop pole's positions.

  14. Clean Room Orientation Notes: Overview and General Safety Completion of Clean Room Orientation allows you to gain access to the clean room to

    E-Print Network [OSTI]

    New Mexico, University of

    and its equipment. 1. Cleanroom Policies a. Only people who have completed clean room orientation Bryant, phone: 272-7671 Cleanroom Manager: Beth Fuchs, phone: 272-7844 Cleanroom Technical Staff: Karen allowed to resume working in the clean room. i. Users may regain cleanroom access sooner by performing

  15. Study of the Effects of Ambient Conditions Upon the Performance of Fan Powered, Infrared Natural Gas Burners

    SciTech Connect (OSTI)

    Clark Atlanta University

    2002-12-02

    The objective of this investigation was to characterize the operation of a fan-powered, infrared burner (IR burner) at various gas compositions and ambient conditions, develop numerical model to simulate the burner performances, and provide design guidelines for appliances containing PIR burners for satisfactory performance.

  16. Gas-surface scattering with multiple collisions in the physisorption potential well Guoqing Fan and J. R. Manson

    E-Print Network [OSTI]

    Manson, Joseph R.

    Gas-surface scattering with multiple collisions in the physisorption potential well Guoqing Fan The problem of gas-surface collisions is developed in terms of a theoretical formalism that allows calcula gas distributions are considered, a monoenergetic incident beam and an equilibrium gas appropriate

  17. Stimulated Emission from a Single Excited Atom in a Waveguide Eden Rephaeli1,* and Shanhui Fan2,

    E-Print Network [OSTI]

    Fan, Shanhui

    Stimulated Emission from a Single Excited Atom in a Waveguide Eden Rephaeli1,* and Shanhui Fan2, 1; published 3 April 2012) We study stimulated emission from an excited two-level atom coupled to a waveguide by the atom, plays a very important role in stimulated emission. Additionally, the temporal duration

  18. PScout: Analyzing the Android Permission Specification Kathy Wain Yee Au, Yi Fan Zhou, Zhen Huang and David Lie

    E-Print Network [OSTI]

    Lie, David

    PScout: Analyzing the Android Permission Specification Kathy Wain Yee Au, Yi Fan Zhou, Zhen Huang and implementation. In this paper, we perform an analysis of the permission system of the Android smartphone OS in an attempt to begin answering some of these questions. Be- cause the documentation of Android's permission

  19. Air Pollution Spring 2010

    E-Print Network [OSTI]

    Pierce, Jeffrey

    ATS 555 Air Pollution Spring 2010 T Th 11:00 ­ 12:15, NESB 101 Instructor: Prof. Sonia Kreidenweis an understanding of types and sources of air pollution. 2. Examine concentrations of air pollutants and their effects on health and welfare. Review regulations governing air pollution. 3. Examine the meteorological

  20. Cromer Cycle Air Conditioner

    Office of Energy Efficiency and Renewable Energy (EERE)

    New Air Conditioning System Uses Desiccant to Transfer Moisture and Increase Efficiency and Capacity

  1. Laboratory evaluation of fan/filter units' aerodynamic and energy performance

    SciTech Connect (OSTI)

    Xu, Tengfang; Jeng, Ming-Shan

    2004-07-27

    The paper discusses the benefits of having a consistent testing method to characterize aerodynamic and energy performance of FFUs. It presents evaluation methods of laboratory-measured performance of ten relatively new, 1220 mm x 610 mm (or 4 ft x 2 ft) fan-filter units (FFUs), and includes results of a set of relevant metrics such as energy performance indices (EPI) based upon the sample FFUs tested. This paper concludes that there are variations in FFUs' performance, and that using a consistent testing and evaluation method can generate compatible and comparable FFU performance information. The paper also suggests that benefits and opportunities exist for our method of testing FFU energy performance to be integrated in future recommended practices.

  2. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01

    leakage than when the hose is removed with refrigerant in gas phase or if a quick con- nect/disconnect sealing valve

  3. Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners

    E-Print Network [OSTI]

    McNeil, Michael A.; Iyer, Maithili

    2008-01-01

    because of the higher electricity rates, higher hours ofin use patterns and electricity rates between commercial andUEC), marginal electricity rates, and discount rates.

  4. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01

    accessed on 11th February 2011. IEA 4E M&B, 2010 “4E Mappingusing CO2 as working fluid, IEA Heat Pump Center Newsletter,Source: Catalog searches, IEA 4E M&B 2010, Baillargeon, 2011

  5. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01

    L ABORATORY China Energy Efficiency Round Robin TestingNeed to Improve the Energy Efficiency of Energy Consumingfor Implementing the China Energy Efficiency Label System (

  6. Research on the Integration Characteristics of Cooling Energy Recovery from Room Exhausting Cool Air in Summer 

    E-Print Network [OSTI]

    Zhang, W.; Wu, J.; Wei, Y.

    2006-01-01

    energy integration I, and effect factor on atmospheric environment of building energy F. The positive effects of these new concepts and methods on traditional approaches are also predicted. Theoretical research on an energy recovery unit that recovers...

  7. Cooling the Planet: Opportunities for Deployment of Superefficient Room Air Conditioners

    E-Print Network [OSTI]

    Shah, Nihar

    2014-01-01

    utility company issues a demand response message in the formsystem receives the demand response message through aas an effective demand response program that achieves

  8. China Energy Efficiency Round Robin Testing Results for Room Air Conditioners

    E-Print Network [OSTI]

    Zhou, Nan

    2010-01-01

    Values of the Energy Efficiency and Energy Efficiency Gradesavin g standards and energy efficiency rat- ings. Energymanufacturers, and energy efficiency testing laboratories

  9. Five ENERGY STAR Room Air Conditioners Fail Testing | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum12, 2015Executive Order14,EnergyFinancingWIPP |DepartmentOpening

  10. Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature? 

    E-Print Network [OSTI]

    Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

    2002-01-01

    The supply air temperature set point for a singleduct constant air volume air handling unit (AHU) system is often reset based on either return air temperature or outside air temperature in order to reduce simultaneous cooling and heating energy...

  11. Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation

    SciTech Connect (OSTI)

    Logue, J.M.; Price, P.N.; Sherman, M.H.; Singer, B.C.

    2011-07-01

    Intake of chemical air pollutants in residences represents an important and substantial health hazard. Sealing homes to reduce air infiltration can save space conditioning energy, but can also increase indoor pollutant concentrations. Mechanical ventilation ensures a minimum amount of outdoor airflow that helps reduce concentrations of indoor emitted pollutants while requiring some energy for fan(s) and thermal conditioning of the added airflow. This work demonstrates a physics based, data driven modeling framework for comparing the costs and benefits of whole-house mechanical ventilation and applied the framework to new California homes. The results indicate that, on a population basis, the health benefits from reduced exposure to indoor pollutants in New California homes are worth the energy costs of adding mechanical ventilation as specified by ASHRAE Standard 62.2.This study determines the health burden for a subset of pollutants in indoor air and the costs and benefits of ASHRAE's mechanical ventilation standard (62.2) for new California homes. Results indicate that, on a population basis, the health benefits of new home mechanical ventilation justify the energy costs.

  12. Control of outdoor air source water heating using variable-speed heat pump

    SciTech Connect (OSTI)

    Dudley, K.F.; Paige, L.E.; Dunshee, K.B.; Voorhis, R.J.

    1991-10-01

    This patent describes a process of controlling an integrated heat pump system of the type. It comprises a variable speed compressor having a discharge port and a suction port; a water heater exchanger coupled to the discharge port of the compressor for heating water by transfer of heat from a compressed heat exchange fluid; an outdoor evaporator heat exchanger having an outdoor fan and a coil receiving the heat exchange fluid from the water heat exchanger and coupled also to the suction port of the compressor, for drawing heat from the outdoor air which heat is transferred to the water in the water heat exchanger; a controller having output channels to control an outdoor fan and the speed of the variable speed compressor and inputs respectively coupled to a water heater setpoint adjustment means, an outdoor air temperature sensor for sensing the outdoor temperature of the outdoor air; and a water temperature sensor for sensing the temperature of the water heated by the water heat exchanger; the process comprising the steps of sensing the outdoor temperature T{sub o}.

  13. A holistic investigation of complexity sources in nuclear power plant control rooms

    E-Print Network [OSTI]

    Sasangohar, Farzan

    2011-01-01

    The nuclear power community in the United States is moving to modernize aging power plant control rooms as well as develop control rooms for new reactors. New generation control rooms, along with modernized control rooms, ...

  14. MA 341 Course Outline Instructor: Andrew Toms Room 720 ...

    E-Print Network [OSTI]

    2011-01-07

    Room 720, Mathematical Sciences Building e-mail: atoms@purdue.edu ... Grading Scheme (subject to change until Jan. 12, as grading hours are not yet known) ...

  15. A Feasibility Study: Ductless Hydronic Distribution Systems with Fan Coil Delivery

    SciTech Connect (OSTI)

    D. Springer, B. Dakin, and C. Backman

    2012-07-01

    The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers with a focus on ductless hydronic delivery systems that utilize water-to-air terminal units in each zone. Results indicate that annual heating and cooling energy use can be reduced by up to 27% assuming replacement of the conventional 13 SEER heat pump and coil with a similarly rated air-to-water heat pump.

  16. B-Target Room Tunnel Redesigned

    SciTech Connect (OSTI)

    Esfandiari, Reza; /San Jose State U. /SLAC

    2010-08-25

    Several groups at SLAC National Accelerator Laboratory are currently working on a RF Modulator prototype for a future linear collider known as the International Linear Collider (ILC). The ILC runs using about a 1000 Klystrons which create high power carrier waves for the particle acceleration. Klystrons receive their electrical input power from modulators. In order to move beyond the prototype phase, the laboratory might expand its ground base further down a tunnel located at the End Station B (ESB) in order to house four new Klystron Modulator Test Stations. This area is known as the B-Target Room Tunnel, and the task was to redesign the tunnel layout for the upcoming changes. The project first began by collecting substantial amount of information about the prototyped project, the tunnel and the researchers feedback of what they would like to see in the upcoming design. Subsequent to numerous planning and presentations, one particular design was. Calculations for this design were then performed for the most complex aspects of the project. Based on the results of the calculations, specific sample beams, welds, bolts and materials were chosen for the possible future construction.

  17. Investigation of room ventilation for improved operation of a downdraft table

    E-Print Network [OSTI]

    Jayaraman, B.; Kristoffersen, A.; Finlayson, E.; Gadgil, A.

    2004-01-01

    Investigation of Room Ventilation for Improved Operation ofInvestigation of Room Ventilation for Improved Operation of

  18. Room Plans for Fall of 2015 March 21, 2015

    E-Print Network [OSTI]

    kitchens, laundry facilities, air conditioning, etc. (All things that our new residence hall will have.) We

  19. Air Traffic Operations | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home Room News Publications Traditional KnowledgeAgenda Agenda NERSC UserAgustin Mihi andAir Leaks»

  20. Alternative Air Conditioning Technologies: Underfloor Air Distribution (UFAD)

    E-Print Network [OSTI]

    Webster, Tom

    2004-01-01

    Refrigerating, and Air-Conditioning Engineers, Inc, 1992.Refrigerating, and Air-Conditioning Engineers, Inc. , 1992.Refrigerating, and Air-Conditioning Engineers, Inc. , 1990.

  1. NOISE AND ROOM ACOUSTICS DISTORTED SPEECH RECOGNITION BY HMM COMPOSITION

    E-Print Network [OSTI]

    Takiguchi, Tetsuya

    NOISE AND ROOM ACOUSTICS DISTORTED SPEECH RECOGNITION BY HMM COMPOSITION Satoshi NAKAMURA, Tetsuya method of an additive noise to that of the convolutional room acoustics distortion. The HMM composition, 2)Composition of distorted speech and noise HMMs in linear spectral domain. The speaker dependent

  2. Exploring former interaction qualities for tomorrow's control room design

    E-Print Network [OSTI]

    Reiterer, Harald

    .g. in power plants or industrial production plants. One essential task in operating control rooms consists by virtual control elements that are operated through desktop computers. However this kind of interaction between power and reality as stated by Jacob et al. (2008): While digitization gave control rooms more

  3. Online Housing Application, Room Selection & Dining Plan Instructions

    E-Print Network [OSTI]

    Cantlon, Jessica F.

    1 Online Housing Application, Room Selection & Dining Plan Instructions 2014-15 Table of Contents Financial Clearance 3 On Campus Housing Requirements 4 Selecting Alone 4 Selecting as a Group 4 Mutual Requests 4 Lottery Days and Times 4 Kinds of Housing 5 On-line Application Process 6 Room Selection Process

  4. General Air Permits (Louisiana)

    Broader source: Energy.gov [DOE]

    Any source, including a temporary source, which emits or has the potential to emit any air contaminant requires an air permit. Facilities with potential emissions less than 5 tons per year of any...

  5. Gravid Mosquito Trap P462 -Trap The ChemTica GMT operates on 4 size D cell batteries. A photo-activated switch turns on the fan

    E-Print Network [OSTI]

    Ishida, Yuko

    batteries. A photo-activated switch turns on the fan at dusk. Manual shutoff is required at dawn to prevent at dawn to prevent loss of trapped mosquitoes. Power is supplied by four D cell batteries. The upper case

  6. Clean Air Bill 

    E-Print Network [OSTI]

    Her Majesty's Stationary Office

    1955-01-01

    The object of this Bill is to implement the principal recommendations in the Report of the Committee on Air Pollution

  7. on man, nature & air pollution

    E-Print Network [OSTI]

    Finlayson-Pitts, Barbara J

    2008-01-01

    on man, nature & air pollution About three decades ago, itand episodes of air pollution the following summer. Wetthe increase in air pollution. This hypothesis generated

  8. Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers

    SciTech Connect (OSTI)

    Coles, Henry C.; Han, Taewon; Price, Phillip N.; Gadgil, Ashok J.; Tschudi, William F.

    2011-07-17

    There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: closed and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percent age of the recirculation air is make-up air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both closed and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups: (1) Outside - coupons sheltered, located near or at the supply air inlet, but located before any filtering, (2) Supply - starting just after initial air filtering continuing inside the plenums and ducts feeding the data center rooms, and (3) Inside located inside the data center rooms near the IT equipment. Each coupon was exposed for thirty days and then sent to a laboratory for a corrosion rate measurement analysis. The goal of this research was to investigate whether gaseous contamination is a concern for U.S. data center operators as it relates to the reliability of IT equipment. More specifically, should there be an increased concern if outside air for IT equipment cooling is used To begin to answer this question limited exploratory measurements of corrosion rates in operating data centers in various locations were undertaken. This study sought to answer the following questions: (1) What is the precision of the measurements (2) What are the approximate statistical distributions of copper and silver corrosion rates in the sampled data centers(3) To what extent are copper and silver corrosion measurements related (4) What is the relationship of corrosion rate measurements between outside-air cooled data centers compared to closed data centers (5) How do corrosivity measurements relate to IT equipment failure rates The data from our limited sample size suggests that most United States data center operators should not be concerned with environmental gaseous contamination causing high IT equipment failure rates even when using outside-air cooling. The research team recommends additional basic research on how environmental conditions, specifically gaseous contamination, affect electronic equipment reliability.

  9. Final Report Independent Verification Survey of the High Flux Beam Reactor, Building 802 Fan House Brookhaven National Laboratory Upton, New York

    SciTech Connect (OSTI)

    Harpeneau, Evan M.

    2011-06-24

    On May 9, 2011, ORISE conducted verification survey activities including scans, sampling, and the collection of smears of the remaining soils and off-gas pipe associated with the 802 Fan House within the HFBR (High Flux Beam Reactor) Complex at BNL. ORISE is of the opinion, based on independent scan and sample results obtained during verification activities at the HFBR 802 Fan House, that the FSS (final status survey) unit meets the applicable site cleanup objectives established for as left radiological conditions.

  10. Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference

    E-Print Network [OSTI]

    Wechsler, Risa H.

    Air Quality: Air Pollutants, SLAC Emissions Sources, and Regulatory Reference Department: Chemical permit regulations are designed to track, record, and control air pollutants belonging to several on chemical classifications. This reference outlines major categories of air pollutants found at SLAC

  11. Geomorphology and morphometric characteristics of alluvial fans, Guadalupe Mountains National Park and adjacent areas, west Texas and New Mexico 

    E-Print Network [OSTI]

    Given, Jeffrey Lyle

    2004-09-30

    , near the Last Glacial Maximum (LGM), that pluvial Lake King (to be discussed in section 2.6) occupied Salt Basin- Crow Flats (Wilkins and Currey, 1997). The late Pleistocene was characterized by a final period of minor uplift that displaced... of the Guadalupe Mountains Region... 20 7 Fault map of the Guadalupe and Brokeoff Mountains ............................ 21 8 Alluvial fans and bajada in Salt Basin-Crow Flats.................................. 22 9 Photograph of a drainage...

  12. Design and Operation of Fan-Coil Units in Using River Water as Chilled Water 

    E-Print Network [OSTI]

    Jiang, A.; Chen, H.; Ma, W.; Zhu, H.

    2006-01-01

    and the properties of indoor-air, and so on. Especially, the temperature of inlet-water can not only make a strong impact on the capacity of the energy afforded by FCUs, but also affect the economic capability of the whole air-conditioning system directly.... As a rule, the designers of A/C systems pay more attention to the design of the inlet-water temperature of FCUs, and many correlative criteria have been established. Generally, considering the economic benefit of an air-conditioning system wholly...

  13. Air to Air Communication Protocol Arjan Durresi1

    E-Print Network [OSTI]

    Jain, Raj

    1 Air to Air Communication Protocol Arjan Durresi1 , Vamsi Paruchuri1 , Leonard Barolli2 and Raj. Louis, MO 63130, USA 314-935-4963, jain@cse.wustl.edu Abstract--We present Air to Air Communication (AAC........................................................2 3. AIR TO AIR COMMUNICATION..............................3 4. SIMULATIONS

  14. Characterization of dynamic change of Fan-delta reservoir properties in water-drive development

    SciTech Connect (OSTI)

    Wu Shenghe; Xiong Qihua; Liu Yuhong

    1997-08-01

    Fan-delta reservoir in Huzhuangji oil field of east China, is a typical highly heterogeneous reservoir. The oil field has been developed by water-drive for 10 years, but the oil recovery is less than 12%, and water cut is over 90%, resulting from high heterogeneity and serious dynamic change of reservoir properties. This paper aims at the study of dynamic change of reservoir properties in water-drive development. Through quantitative imaging analysis and mercury injection analysis of cores from inspection wells, the dynamic change of reservoir pore structure in water-drive development was studied. The results show that the {open_quotes}large pore channels{close_quotes} develop in distributary channel sandstone and become larger in water-drive development, resulting in more serious pore heterogeneity. Through reservoir sensitivity experiments, the rock-fluid reaction in water-drive development is studied. The results show the permeability of some distal bar sandstone and deserted channel sandstone becomes lower due to swelling of I/S clay minerals in pore throats. OD the other hand, the permeability of distributary channel and mouth bar sandstone become larger because the authigenic Koalinites in pore throats are flushed away with the increase of flow rate of injection water. Well-logging analysis of flooded reservoirs are used to study the dynamic change of reservoir properties in various flow units. The distribution of remaining oil is closely related to the types and distribution of flow units.

  15. Toward green systems for cleanrooms: Energy efficient fan-filter units

    SciTech Connect (OSTI)

    Jeng, Ming-Shan; Xu, Tengfang; Lan, Chao-Ho

    2004-07-12

    The paper presents results of laboratory-measured performance of fan-filter units (FFUs) used for cleanrooms. A total of twenty FFUs collected from the market were tested, including thirteen 1220 mm x 610 mm (or 4 ft x 2 ft) units and seven 1220 mm x 1220 mm (or 4 ft x 4 ft) units. The paper concludes that there are wide variations in FFUs energy performance, and that there are opportunities in improving energy efficiency and lowering operating costs of FFUs. Furthermore, the paper suggests the benefits of having a uniform method for testing and reporting FFU performance. Such a testing method and recommended practice guideline is under development, with heavy input from FFU suppliers, users, and independent institutions that include Lawrence Berkeley National Laboratory (LBNL), Industrial Technology Research Institute (ITRI), and Institute of Environmental Sciences and Technology (IEST). An integrated approach with the participation from designers, suppliers, users, and utility companies can help to identify energy-efficient FFUs that are required for many cleanroom applications.

  16. Oil and Gas Air Heaters 

    E-Print Network [OSTI]

    Kou, G.; Wang, H.; Zhou, J.

    2006-01-01

    Most conventional air heaters adopt indirect heat transfer, which uses combustion gases to indirectly heat fresh air by heating surfaces to generate hot air used for material drying and dehumidification. We call them indirect air heaters. However...

  17. ORIGINAL ARTICLE Ambient Air Pollution

    E-Print Network [OSTI]

    Mulholland, James A.

    ORIGINAL ARTICLE Ambient Air Pollution and Cardiovascular Emergency Department Visits Kristi Busico ambient air pollutants and cardiovascular disease (CVD), the roles of the physicochemical components the relation between ambient air pollution and cardiovascular conditions using ambient air quality data

  18. Air Cooling for High Temperature Power Electronics (Presentation)

    SciTech Connect (OSTI)

    Waye, S.; Musselman, M.; King, C.

    2014-09-01

    Current emphasis on developing high-temperature power electronics, including wide-bandgap materials such as silicon carbide and gallium nitride, increases the opportunity for a completely air-cooled inverter at higher powers. This removes the liquid cooling system for the inverter, saving weight and volume on the liquid-to-air heat exchanger, coolant lines, pumps, and coolant, replacing them with just a fan and air supply ducting. We investigate the potential for an air-cooled heat exchanger from a component and systems-level approach to meet specific power and power density targets. A proposed baseline air-cooled heat exchanger design that does not meet those targets was optimized using a parametric computational fluid dynamics analysis, examining the effects of heat exchanger geometry and device location, fixing the device heat dissipation and maximum junction temperature. The CFD results were extrapolated to a full inverter, including casing, capacitor, bus bar, gate driver, and control board component weights and volumes. Surrogate ducting was tested to understand the pressure drop and subsequent system parasitic load. Geometries that met targets with acceptable loads on the system were down-selected for experimentation. Nine baseline configuration modules dissipated the target heat dissipation, but fell below specific power and power density targets. Six optimized configuration modules dissipated the target heat load, exceeding the specific power and power density targets. By maintaining the same 175 degrees C maximum junction temperature, an optimized heat exchanger design and higher device heat fluxes allowed a reduction in the number of modules required, increasing specific power and power density while still maintaining the inverter power.

  19. Magnetic Refrigeration Technology for High Efficiency Air Conditioning

    SciTech Connect (OSTI)

    Boeder, A; Zimm, C

    2006-09-30

    Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

  20. Experimental investigation and modeling of a direct-coupled PV/T air collector

    SciTech Connect (OSTI)

    Shahsavar, A.; Ameri, M.

    2010-11-15

    Photovoltaic/thermal (PV/T) systems refer to the integration of photovoltaic and solar thermal technologies into one single system, in that both useful heat energy and electricity are produced. The impetus of this paper is to model a direct-coupled PV/T air collector which is designed, built, and tested at a geographic location of Kerman, Iran. In this system, a thin aluminum sheet suspended at the middle of air channel is used to increase the heat exchange surface and consequently improve heat extraction from PV panels. This PV/T system is tested in natural convection and forced convection (with two, four and eight fans operating) and its unsteady results are presented in with and without glass cover cases. A theoretical model is developed and validated against experimental data, where good agreement between the measured values and those calculated by the simulation model were achieved. Comparisons are made between electrical performance of the different modes of operation, and it is concluded that there is an optimum number of fans for achieving maximum electrical efficiency. Also, results show that setting glass cover on photovoltaic panels leads to an increase in thermal efficiency and decrease in electrical efficiency of the system. (author)

  1. High-throughput liquid-absorption air-sampling apparatus and methods

    DOE Patents [OSTI]

    Zaromb, Solomon (95706 William Dr., Hinsdale, IL 60521)

    2000-01-01

    A portable high-throughput liquid-absorption air sampler [PHTLAAS] has an asymmetric air inlet through which air is drawn upward by a small and light-weight centrifugal fan driven by a direct current motor that can be powered by a battery. The air inlet is so configured as to impart both rotational and downward components of motion to the sampled air near said inlet. The PHTLAAS comprises a glass tube of relatively small size through which air passes at a high rate in a swirling, highly turbulent motion, which facilitates rapid transfer of vapors and particulates to a liquid film covering the inner walls of the tube. The pressure drop through the glass tube is <10 cm of water, usually <5 cm of water. The sampler's collection efficiency is usually >20% for vapors or airborne particulates in the 2-3.mu. range and >50% for particles larger than 4.mu.. In conjunction with various analyzers, the PHTLAAS can serve to monitor a variety of hazardous or illicit airborne substances, such as lead-containing particulates, tritiated water vapor, biological aerosols, or traces of concealed drugs or explosives.

  2. Determining the Right Air Quality for Your Compressed Air System - Compressed Air Tip Sheet #5

    SciTech Connect (OSTI)

    2004-08-01

    BestPractices Program tip sheet discussing how to determine the right air quality for compressed air systems.

  3. Financial Aid and Student Records Student Wing, Room 119

    E-Print Network [OSTI]

    Suzuki, Masatsugu

    Financial Aid and Student Records Student Wing, Room 119 PO Box 6000 Binghamton, New York 13902 or spring semester. · Any student wishing to drop all summer or winter classes is not required to complete

  4. Modeling control room crews for accident sequence analysis

    E-Print Network [OSTI]

    Huang, Y. (Yuhao)

    1991-01-01

    This report describes a systems-based operating crew model designed to simulate the behavior of an nuclear power plant control room crew during an accident scenario. This model can lead to an improved treatment of potential ...

  5. Control and Room Temperature Optimization of Energy Efficient Buildings

    SciTech Connect (OSTI)

    Djouadi, Seddik M; Kuruganti, Phani Teja

    2012-01-01

    The building sector consumes a large part of the energy used in the United States and is responsible for nearly 40% of greenhouse gas emissions. It is therefore economically and environmentally important to reduce the building energy consumption to realize massive energy savings. In this paper, a method to control room temperature in buildings is proposed. The approach is based on a distributed parameter model represented by a three dimensional (3D) heat equation in a room with heater/cooler located at ceiling. The latter is resolved using finite element methods, and results in a model for room temperature with thousands of states. The latter is not amenable to control design. A reduced order model of only few states is then derived using Proper Orthogonal Decomposition (POD). A Linear Quadratic Regulator (LQR) is computed based on the reduced model, and applied to the full order model to control room temperature.

  6. International Symposium on Air Breathing Engines, 8th, Cincinnati, OH, June 14-19, 1987, Proceedings

    SciTech Connect (OSTI)

    Billig, F.S.

    1987-01-01

    The present conference on air-breathing aircraft engine technology considers topics in inlet design, radial-flow turbomachinery, fuel injection and combustion systems, axial flow compressor design and performance, ramjet configurations, turbine flow phenomena, engine control and service life, fluid flow-related problems, engine diagnostic methods, propfan design, combustor performance and pollutant chemistry, combustion dynamics, and engine system analysis. Attention is given to thrust-vectoring systems, supersonic missile air intakes, three-dimensional centrifugal compressors, airblast atomizers, secondary flows in axial flow compressors, axial compressor blade tip clearance flows, hydrogen scramjets with sidewall injection, the performance of a variable-geometry turbine, advanced tip clearance control systems, rotary jet mixing, fan blade aeroelastic behavior, flow dynamics in combustion processes, and the technology of low cost turbomachinery.

  7. Energy savings and economics of advanced control strategies for packaged air conditioners with gas heat

    SciTech Connect (OSTI)

    Wang, Weimin; Katipamula, Srinivas; Huang, Yunzhi; Brambley, Michael R.

    2013-10-01

    This paper presents an evaluation of the potential energy savings from adding advanced control to existing packaged air conditioners. Advanced control options include air-side economizer, multi-speed fan control, demand control ventilation and staged cooling. The energy and cost savings from the different control strategies individually and in combination are estimated using the EnergyPlus detailed energy simulation program for four building types, namely, a small office building, a stand-alone retail building, a strip mall building and a supermarket building. For each of the four building types, the simulation was run for 16 locations covering all 15 climate zones in the U.S. The maximum installed cost of a replacement controller that provides acceptable payback periods to owners is estimated.

  8. Using a Research Simulator for Validating Control Room Modernization Concepts

    SciTech Connect (OSTI)

    Ronald L. Boring; Vivek Agarwal; Julius J. Persensky; Jeffrey C. Joe

    2012-05-01

    The Light Water Reactor Sustainability Program is a research, development, and deployment program sponsored by the United States Department of Energy. The program is operated in close collaboration with industry research and development programs to provide the technical foundations for licensing and managing the long-term, safe, and economical operation of nuclear power plants that are currently in operation. Advanced instrumentation and control (I&C) technologies are needed to support the continued safe and reliable production of power from nuclear energy systems during sustained periods of operation up to and beyond their expected licensed lifetime. This requires that new capabilities to achieve process control be developed and eventually implemented in existing nuclear control rooms. It also requires that approaches be developed and proven to achieve sustainability of I&C systems throughout the period of extended operation. Idaho National Laboratory (INL) is working closely with nuclear utilities to develop technologies and solutions to help ensure the safe life extension of current reactors. One of the main areas of focus is control room modernization. Current analog control rooms are growing obsolete, and it is difficult for utilities to maintain them. Using its reconfigurable control room simulator adapted from a training simulator, INL serves as a neutral test bed for implementing new control room system technologies and assisting in control room modernization efforts across.

  9. Indoor Air Quality

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    In Focus For decades, teams of Berkeley Lab scientists have investigated the ways that indoor air quality affects human health-from cognitive ability to personal comfort...

  10. Personal continuous air monitor

    DOE Patents [OSTI]

    Morgan, Ronald G. (Los Alamos, NM); Salazar, Samuel A. (Albuquerque, NM)

    2000-01-01

    A personal continuous air monitor capable of giving immediate warning of the presence of radioactivity has a filter/detector head to be worn in the breathing zone of a user, containing a filter mounted adjacent to radiation detectors, and a preamplifier. The filter/detector head is connected to a belt pack to be worn at the waist or on the back of a user. The belt pack contains a signal processor, batteries, a multichannel analyzer, a logic circuit, and an alarm. An air pump also is provided in the belt pack for pulling air through the filter/detector head by way of an air tube.

  11. Operando NMR and XRD study of chemically synthesized LiCx oxidation in a dry room environment

    SciTech Connect (OSTI)

    Sacci, Robert L [ORNL; Gill, Lance W [ORNL; Hagaman, Edward {Ed} W [ORNL; Dudney, Nancy J [ORNL

    2015-01-01

    We test the stability of pre-lithiated graphite anodes for Li-ion batteries in a dry room battery processing room. The reaction between LiCx and laboratory air was followed using operando NMR and x-ray diffraction as these methods are sensitive to change in Li stoichiometry in graphite. There is minimal reactivity between LiC6 and N2, CO2 or O2; however, LiC6 reacts with moisture to form lithium (hydr)oxide. The reaction rate follows zero-order kinetics with respects to intercalated lithium suggesting that lithium transport through the graphite is fast. The reaction mechanism occurs by sequential formation of higher stages LiC12, then LiC18, and then LiC24 as the hydrolysis proceeds to the formation of LixOHy and graphite end products. Slowing down the formation rate of the LixOHy passivation layer stabilizes of the higher stages.

  12. Control Room operations: an investigation of the task of the operator in a Colliery Control Room. Final report

    SciTech Connect (OSTI)

    Simpson, G.C.; Best, C.F.; Ferguson, C.A.; Graveling, R.A.; Nicholl, A.G.M.

    1982-09-01

    A detailed study of the ergonomics aspects of four representative Colliery Control Rooms was carried out. Numerous ergonomics limitations, many common to each of the control rooms studied, were identified particularly in relation to workspace dimensions, console layout and lighting. In order to overcome these limitations in future designs, a report detailing the Ergonomics Principles of Colliery Control Room design and Layout was prepared on the basis of the information obtained. Task analysis carried out during the studies revealed that control room operators could have a direct effect on production and that ergonomics aspects were involved in these situations. Indications of potential ergonomics problems in the wider sphere of job design were also identified particularly in relation to information handling.

  13. Issuance 2014-11-21:Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Ceiling Fans: Availability of the Preliminary Technical Support Document, Notice of Comment Period Extension

    Broader source: Energy.gov [DOE]

    Energy Efficiency Program for Consumer Products: Energy Conservation Standards for Ceiling Fans: Availability of the Preliminary Technical Support Document, Notice of Comment Period Extension

  14. Leads Tactical Air Control Party (TACP) and Air Support

    E-Print Network [OSTI]

    Stuart, Steven J.

    Air LiAison officer Leads Tactical Air Control Party (TACP) and Air Support Operations Center (ASOC) operations. Provides Command and Control, and Execution of Air, Space, and Cyber power. Primary advisor and advocate to the Ground Force Commander ensuring effective Air, Space, and Cyber power integration with US

  15. Appendix F. Air Permits Appendix F. Air Permits F-3

    E-Print Network [OSTI]

    Pennycook, Steve

    Appendix F. Air Permits #12;#12;Appendix F. Air Permits F-3 Table F.1. Air Permits at the Y-12 Chemical Process Operation 01-0020-21 554701 Air Bearing Operation 01-0020-05 554701 Special Processing Purification Facility #12;Oak Ridge Reservation F-4 Appendix F. Air Permits Table F.2. Oak Ridge National

  16. Appendix E. Air Permits Appendix E. Air Permits E-3

    E-Print Network [OSTI]

    Pennycook, Steve

    Appendix E. Air Permits #12;#12;Appendix E. Air Permits E-3 Table E.1. Air permits at the Y-12 Chemical Process Operation 01-0020-21 554701 Air Bearing Operation 01-0020-05 554701 Special Processing Operation 01-0020-68 554701 Disassembly and Storage Operation #12;Oak Ridge Reservation E-4 Appendix E. Air

  17. Space Utilization 1:44PM Average Weekly Utilization for Sections Only by Room Type and Size with Primetime

    E-Print Network [OSTI]

    Oviedo, Néstor J.

    Space Utilization 1:44PM 5/22/2015 Average Weekly Utilization for Sections Only by Room Type and Size with Primetime Dates: 1/20/2015 - 5/8/2015 # of Rooms Room Hrs. Room Hr. Util.Room Type - Capacity Prime Room Hrs. Prime Room Hr. Util Prime Ratio Hours in Standard week: 70.00 hoursTerm Weeks: 16

  18. Space Utilization 8:39AM Average Weekly Utilization for Sections Only by Room Type and Size with Primetime

    E-Print Network [OSTI]

    Oviedo, Néstor J.

    Space Utilization 8:39AM 12/4/2014 Average Weekly Utilization for Sections Only by Room Type and Size with Primetime Dates: 8/28/2014 - 12/12/2014 # of Rooms Room Hrs. Room Hr. Util.Room Type - Capacity Prime Room Hrs. Prime Room Hr. Util Prime Ratio Hours in Standard week: 70.00 hoursTerm Weeks: 16

  19. Energy Efficiency in Small Server Rooms: Field Surveys and Findings

    SciTech Connect (OSTI)

    Cheung, Iris; Greenberg, Steve; Mahdavi, Roozbeh; Brown, Richard; Tschudi, William

    2014-08-11

    Fifty-seven percent of US servers are housed in server closets, server rooms, and localized data centers, in what are commonly referred to as small server rooms, which comprise 99percent of all server spaces in the US. While many mid-tier and enterprise-class data centers are owned by large corporations that consider energy efficiency a goal to minimize business operating costs, small server rooms typically are not similarly motivated. They are characterized by decentralized ownership and management and come in many configurations, which creates a unique set of efficiency challenges. To develop energy efficiency strategies for these spaces, we surveyed 30 small server rooms across eight institutions, and selected four of them for detailed assessments. The four rooms had Power Usage Effectiveness (PUE) values ranging from 1.5 to 2.1. Energy saving opportunities ranged from no- to low-cost measures such as raising cooling set points and better airflow management, to more involved but cost-effective measures including server consolidation and virtualization, and dedicated cooling with economizers. We found that inefficiencies mainly resulted from organizational rather than technical issues. Because of the inherent space and resource limitations, the most effective measure is to operate servers through energy-efficient cloud-based services or well-managed larger data centers, rather than server rooms. Backup power requirement, and IT and cooling efficiency should be evaluated to minimize energy waste in the server space. Utility programs are instrumental in raising awareness and spreading technical knowledge on server operation, and the implementation of energy efficiency measures in small server rooms.

  20. History of Air Conditioning

    Office of Energy Efficiency and Renewable Energy (EERE)

    We take it for granted but what would life be like without the air conditioner? Once considered a luxury, this invention is now an essential, allowing us to cool everything from homes, businesses, businesses, data centers, laboratories and other buildings vital to our daily lives. Explore this timeline to learn some of the key dates in the history of air conditioning.

  1. Recirculating electric air filter

    DOE Patents [OSTI]

    Bergman, W.

    1985-01-09

    An electric air filter cartridge has a cylindrical inner high voltage electrode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  2. Compressed Air System Optimization 

    E-Print Network [OSTI]

    Aegerter, R.

    1999-01-01

    Several years ago I went to a gas station and noticed that my car's tires were low on air. I saw the gas station had an air compressor, but it cost a quarter to use the compressor. I paid my quarter and used the compressor. I realized...

  3. Recirculating electric air filter

    DOE Patents [OSTI]

    Bergman, Werner (Pleasanton, CA)

    1986-01-01

    An electric air filter cartridge has a cylindrical inner high voltage eleode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

  4. Passive Room-to-Room Air Transfer, Fresno, California (Fact Sheet), Building America Case Study: Whole-House Solutions for Existing Homes, Building Technologies Office (BTO)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankADVANCED MANUFACTURINGEnergy Bills andOrder 422.1, CONDUCT P -Particle ReceiverEnergy PasadenaPassive

  5. Solar panel driven air purging apparatus for motor vehicles

    SciTech Connect (OSTI)

    Bobier, J.A.; Brown, G.E.

    1992-02-18

    This patent describes improvement in a motor vehicle having an enclosable cabin an internal combustion engine, a battery, an ignition switch having an on position for enabling the internal combustion engine and an off position, an electric motor coupled in driving relationship with an air circulating fan for circulating air through the cabin. The improvement comprises: a solar panel mounted upon the vehicle having a panel output exhibiting variable voltage levels including a peak voltage level and substantially constant current; a power transfer regulator for transferring power form the panel to the motor when enabled, including: energy storage means connectable across the panel output and chargeable by the current to variable charge levels; solid-state switch means connected in energy transfer relationship with the energy storage means and actuable between conducting and non-conducting states when the power transfer regulator is enabled; inductor means connected with the solid-state switch means and connectable with the electric motor for conveying current thereto from the panel and the energy storage means when the solid-state switch means is in the conducting state.

  6. EMISSIONS TO AIR OPERATIONAL PROCEDURE

    E-Print Network [OSTI]

    Harman, Neal.A.

    PURPOSE: To minimise emissions and discharges to air from boilers, fume cupboards, air conditioning Act 1993. SCOPE: All air-conditioning and refrigeration equipment METHOD: Air-conditioning or fluorinated greenhouse gases (air conditioning units, refrigeration units etc.) 2. Several approved

  7. Low-Flow Liquid Desiccant Air-Conditioning: Demonstrated Performance and Cost Implications

    SciTech Connect (OSTI)

    Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.; Lowenstein, A.

    2014-09-01

    Cooling loads must be dramatically reduced when designing net-zero energy buildings or other highly efficient facilities. Advances in this area have focused primarily on reducing a building's sensible cooling loads by improving the envelope, integrating properly sized daylighting systems, adding exterior solar shading devices, and reducing internal heat gains. As sensible loads decrease, however, latent loads remain relatively constant, and thus become a greater fraction of the overall cooling requirement in highly efficient building designs, particularly in humid climates. This shift toward latent cooling is a challenge for heating, ventilation, and air-conditioning (HVAC) systems. Traditional systems typically dehumidify by first overcooling air below the dew-point temperature and then reheating it to an appropriate supply temperature, which requires an excessive amount of energy. Another dehumidification strategy incorporates solid desiccant rotors that remove water from air more efficiently; however, these systems are large and increase fan energy consumption due to the increased airside pressure drop of solid desiccant rotors. A third dehumidification strategy involves high flow liquid desiccant systems. These systems require a high maintenance separator to protect the air distribution system from corrosive desiccant droplet carryover and so are more commonly used in industrial applications and rarely in commercial buildings. Both solid desiccant systems and most high-flow liquid desiccant systems (if not internally cooled) add sensible energy which must later be removed to the air stream during dehumidification, through the release of sensible heat during the sorption process.

  8. Air Resources: Prevention and Control of Air Contamination and...

    Broader source: Energy.gov (indexed) [DOE]

    limits and permitting and operational requirements for facilities that may contribute to air emissions. General air quality standards and standards for specific contaminants are...

  9. Abatement of Air Pollution: Prohibition of Air Pollution (Connecticut...

    Broader source: Energy.gov (indexed) [DOE]

    All air pollution not otherwise covered by these regulations is prohibited. Stationary sources which cause air pollution must be operated in accordance with all applicable...

  10. Abatement of Air Pollution: Hazardous Air Pollutants (Connecticut...

    Broader source: Energy.gov (indexed) [DOE]

    allowable stack concentrations and hazard limiting values for the emission of hazardous air pollutants. The regulations also discuss sampling procedures for hazardous air...

  11. Air Pollution Control Regulations: No. 7 - Emission of Air Contaminant...

    Broader source: Energy.gov (indexed) [DOE]

    with the enjoyment of life and property. The criteria for determining compliance is listed in the regulations, and is based on other air pollution and ambient air standards...

  12. Air ejector augmented compressed air energy storage system

    DOE Patents [OSTI]

    Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

    1980-01-01

    Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

  13. Renewables and air quality

    SciTech Connect (OSTI)

    Wooley, D.R.

    2000-08-01

    The US heavy reliance on fossil fuels is a central obstacle to improving air quality and preventing catastrophic climate change. To solve this problem will require a combination of financial incentives and market rules that strongly encourage development of renewable energy resources to meet electric power demand. One promising policy option is to allow renewable energy resources to directly participate in air pollution emission trading mechanisms. Currently, the clean air benefits of renewable energy generally go unrecognized by regulators, under-appreciated by consumers and uncompensated by markets. Renewable energy is a key clean air alternative to conventional electricity generation, and the development of renewables could be stimulated by changes to the Clean Air Act's emissions trading programs. As Congress revisits clean air issues over the next several years, renewable energy representatives could push for statutory changes that reward the renewable energy industry for the air quality benefits it provides. By also becoming involved in key US Environmental Protection Agency (EPA) and state rule-making cases, the renewables industry could influence the structure of emissions trading programs and strengthen one of the most persuasive arguments for wind, solar and biomass energy development.

  14. Health Hazards in Indoor Air

    E-Print Network [OSTI]

    Logue, Jennifer M.

    2012-01-01

    Health Hazards in Indoor Air. In Proceedings of the 2010for VOCs from post-1990 indoor air concentration studies inUnion project on indoor air pollutants. Allergy, 2008. 63(

  15. Texas Clean Air Act (Texas)

    Broader source: Energy.gov [DOE]

    This Act is designed to safeguard the state's air resources from pollution by requiring the control and abatement of air pollution and emissions of air contaminants, consistent with the protection...

  16. Integrated intelligent systems in advanced reactor control rooms

    SciTech Connect (OSTI)

    Beckmeyer, R.R.

    1989-01-01

    An intelligent, reactor control room, information system is designed to be an integral part of an advanced control room and will assist the reactor operator's decision making process by continuously monitoring the current plant state and providing recommended operator actions to improve that state. This intelligent system is an integral part of, as well as an extension to, the plant protection and control systems. This paper describes the interaction of several functional components (intelligent information data display, technical specifications monitoring, and dynamic procedures) of the overall system and the artificial intelligence laboratory environment assembled for testing the prototype. 10 refs., 5 figs.

  17. Air heating system

    DOE Patents [OSTI]

    Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

    1983-03-01

    A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

  18. Study on Influencing Factors of Night Ventilation in Office Rooms 

    E-Print Network [OSTI]

    Wang, Z.; Sun, X.

    2006-01-01

    in Harbin are simulated and analyzed. The results show that the inlet velocity and area can influence the effects of night ventilation. When the inlet velocity is 2.5m/s, both indoor air temperature and air velocity meet ASHRAE standard 55-2004. Indoor...

  19. FANNING OUT OF THE SOLAR f-MODE IN THE PRESENCE OF NON-UNIFORM MAGNETIC FIELDS?

    SciTech Connect (OSTI)

    Singh, Nishant K.; Brandenburg, Axel [Nordita, KTH Royal Institute of Technology and Stockholm University, Roslagstullsbacken 23, SE-10691 Stockholm (Sweden); Rheinhardt, Matthias, E-mail: nishant@nordita.org [Physics Department, Gustaf Hällströmin katu 2a, PO Box 64, FI-00014 University of Helsinki, Helsinki (Finland)

    2014-11-01

    We show that in the presence of a magnetic field that is varying harmonically in space, the fundamental mode, or f-mode, in a stratified layer is altered in such a way that it fans out in the diagnostic k? diagram, with mode power also within the fan. In our simulations, the surface is defined by a temperature and density jump in a piecewise isothermal layer. Unlike our previous work (Singh et al. 2014), where a uniform magnetic field was considered, here we employ a non-uniform magnetic field together with hydromagnetic turbulence at length scales much smaller than those of the magnetic field. The expansion of the f-mode is stronger for fields confined to the layer below the surface. In some of those cases, the k? diagram also reveals a new class of low-frequency vertical stripes at multiples of twice the horizontal wavenumber of the background magnetic field. We argue that the study of the f-mode expansion might be a new and sensitive tool to determine subsurface magnetic fields with azimuthal or other horizontal periodicity.

  20. Compressed Air Systems

    Broader source: Energy.gov [DOE]

    There are incentives for variable frequency drive screw compressors (10-40 HP), air receivers/tanks for load/no-load compressors, cycling refrigerated dryers (up to 200 CFM capacity), no-loss...

  1. Air conditioning system

    DOE Patents [OSTI]

    Lowenstein, Andrew; Miller, Jeffrey; Gruendeman, Peter; DaSilva, Michael

    2005-02-01

    An air conditioner comprises a plurality of plates arranged in a successively stacked configuration with portions thereof having a spaced apart arrangement, and defining between successive adjacent pairs of plates at the spaced apart portions a first and second series of discrete alternating passages wherein a first air stream is passed through the first series of passages and a second air stream is passed through the second series of passages; and said stacked configuration of plates forming integrally therewith a liquid delivery means for delivering from a source a sufficient quantity of a liquid to the inside surfaces of the first series of fluid passages in a manner which provides a continuous flow of the liquid from a first end to a second end of the plurality of plates while in contact with the first air stream.

  2. Guide to Air Sealing

    SciTech Connect (OSTI)

    2011-02-01

    Air sealing is one of the most cost-effective ways to improve the comfort and energy efficiency of your home. Hire a certified professional contractor for best results.

  3. Air bag restraint device

    DOE Patents [OSTI]

    Marts, D.J.; Richardson, J.G.

    1995-10-17

    A rear-seat air bag restraint device is disclosed that prevents an individual, or individuals, from continuing violent actions while being transported in a patrol vehicle`s rear seat without requiring immediate physical contact by the law enforcement officer. The air bag is activated by a control switch in the front seat and inflates to independently restrict the amount of physical activity occurring in the rear seat of the vehicle while allowing the officer to safely stop the vehicle. The air bag can also provide the officer additional time to get backup personnel to aid him if the situation warrants it. The bag is inflated and maintains a constant pressure by an air pump. 8 figs.

  4. Retrofit Air Preheat Economics 

    E-Print Network [OSTI]

    Goolsbee, J. A.

    1981-01-01

    Retrofit air preheat systems are the most reliable and efficient means to effect significant energy conservation for large existing industrial furnaces. Units can be quickly installed without a lengthy shutdown, and the furnace efficiency can...

  5. Combustion Air Control 

    E-Print Network [OSTI]

    Hughart, C. L.

    1979-01-01

    to 100%. If the air and fuel controls are on automatic but the flue gas oxygen content cannot be lowered to 4% oxygen without the boiler smoking, burner problems may be suspected. The trouble may be traced to dirty or improperly assembled oil guns..., combustion air distribution problems, vaporizing steam control problems, oil viscosity, or flow control problems. It is very important to have all oil guns operating properly before proceeding with a combustion test. The minimum stack gas oxygen level you...

  6. MBG Room Request Instructions: Outlook Web App 1 | P a g e

    E-Print Network [OSTI]

    Pawlowski, Wojtek

    MBG Room Request Instructions: Outlook Web App 1 | P a g e Rooms*: biotech180 biotech202 biotech271 biotech302 biotech371 biotech371 biotech402 biotech471 Equipment: mbg3dproj mbglaptopmac mbglaptoppd a space between biotech and the room number when entering the information as outlined below. #12;MBG Room

  7. Physics 619: Fields II Fall 2014 Room: ARC-212

    E-Print Network [OSTI]

    Gustafsson, Torgny

    Physics 619: Fields II Fall 2014 Room: ARC-212 Time: Monday, Thursday 10:20-11:40 AM Instructor: Sergei Lukyanov office: Serin E364 tel: (848) 445-9060 (office) e-mail: sergei@physics.rutgers.edu (the to the published version) can be found at http://web.physics.ucsb.edu/ mark/ms-qft-DRAFT.pdf Homework

  8. Authorized Investigator's Laboratory Survey Record Room Diagram and Survey Instruments

    E-Print Network [OSTI]

    Sniadecki, Nathan J.

    . 4) All records must be available for inspection and kept for 3 calendar years. Survey InstrumentsAuthorized Investigator's Laboratory Survey Record Room Diagram and Survey Instruments u Instrument Code * Model # Serial # Type Action Level Instrument action level is twice the bkg count

  9. Information Foraging in Nuclear Power Plant Control Rooms

    SciTech Connect (OSTI)

    R.L. Boring

    2011-09-01

    nformation foraging theory articulates the role of the human as an 'informavore' that seeks information and follows optimal foraging strategies (i.e., the 'information scent') to find meaningful information. This paper briefly reviews the findings from information foraging theory outside the nuclear domain and then discusses the types of information foraging strategies operators employ for normal and off-normal operations in the control room. For example, operators may employ a predatory 'wolf' strategy of hunting for information in the face of a plant upset. However, during routine operations, the operators may employ a trapping 'spider' strategy of waiting for relevant indicators to appear. This delineation corresponds to information pull and push strategies, respectively. No studies have been conducted to determine explicitly the characteristics of a control room interface that is optimized for both push and pull information foraging strategies, nor has there been empirical work to validate operator performance when transitioning between push and pull strategies. This paper explores examples of control room operators as wolves vs. spiders and con- cludes by proposing a set of research questions to investigate information foraging in control room settings.

  10. HOW OFTEN SHOULD YOU CLEAN YOUR ROOM? KIMBALL MARTIN

    E-Print Network [OSTI]

    Martin, Kimball

    . INTRODUCTION Suppose you have n objects in your room which are totally ordered. For simplicity, let us say a logarithmic cost still seems like a good model for this process.) The theory of searching (and sorting will wind up as an unsorted pile on your desk. Then when you search for a book, you essentially have to go

  11. Numerical modelling and analysis of a room temperature magnetic

    E-Print Network [OSTI]

    and analysis of a room temperature magnetic refrigeration system Department: Fuel Cells and Solid State are separated by channels of a heat transfer fluid. The time-dependent model solves the momentum and continuity equations of the flow of the heat transfer fluid and the coupled energy equations of the heat transfer

  12. Blended Interaction as an Approach for Holistic Control Room Design

    E-Print Network [OSTI]

    Reiterer, Harald

    ranging from energy production to traffic control. Copyright is held by the author/owner(s). CHI'13, April or industrial production plants. In today's control rooms operators mainly interact with these processes via of Konstanz 78464 Konstanz, Germany Simon.Butscher@uni-konstanz.de Jens Müller Human-Computer Interaction

  13. A CONVECTIVE HEAT TRANSFER MODEL FOR SIMULATION OF ROOMS WITH

    E-Print Network [OSTI]

    Quest Information and Learning Company 300 North Zeeb Road P.O. Box 1346 Ann Arbor, MI 48106-1346 by ProQuest Information and Learning Company. #12;II A CONVECTIVE HEAT TRANSFER MODEL FOR SIMULATION OF ROOMS. Seeing him grow gave me a new level of energy and hope. Without a doubt, my family members have been

  14. inAir: Sharing Indoor Air Quality Measurements and Visualizations

    E-Print Network [OSTI]

    Mankoff, Jennifer

    evidence has indicated that indoor air pollution within homes and other buildings can be worse than the outdoor air pollution in even the largest and most industrialized cities. For example, the California Air Resources Board estimates that indoor air pollutant levels are 25-62% greater than outside levels [4

  15. inAir: Sharing Indoor Air Quality Measurements and Visualizations

    E-Print Network [OSTI]

    Paulos, Eric

    the outdoor air pollution in even the largest and most industrialized cities. For example, the California Air evidence has indicated that indoor air pollution within homes and other buildings can be worse than Resources Board estimates that indoor air pollutant levels are 25-62% greater than outside levels [4

  16. Nuclear power plant control room operator control and monitoring tasks

    SciTech Connect (OSTI)

    Bovell, C.R.; Beck, M.G. [Concord Associates, Inc., Knoxville, TN (United States); Carter, R.J. [Oak Ridge National Labs., TN (United States)

    1998-07-01

    Oak Ridge National Laboratory is conducting a research project the purpose of which is to develop the technical bases for regulatory review criteria for use in evaluating the safety implications of human factors associated with the use of artificial intelligence and expert systems, and with advanced instrumentation and control (I and C) systems in nuclear power plants (NPP). This report documents the results from Task 8 of that project. The primary objectives of the task was to identify the scope and type of control and monitoring tasks now performed by control-room operators. Another purpose was to address the types of controls and safety systems needed to operate the nuclear plant. The final objective of Task 8 was to identify and categorize the type of information and displays/indicators required to monitor the performance of the control and safety systems. This report also discusses state-of-the-art controls and advanced display devices which will be available for use in control-room retrofits and in control room of future plants. The fundamental types of control and monitoring tasks currently conducted by operators can be divided into four classifications: function monitoring tasks, control manipulation tasks, fault diagnostic tasks, and administrative tasks. There are three general types of controls used in today`s NPPs, switches, pushbuttons, and analog controllers. Plant I and C systems include components to achieve a number of safety-related functions: measuring critical plant parameters, controlling critical plant parameters within safety limits, and automatically actuating protective devices if safe limits are exceeded. The types of information monitored by the control-room operators consist of the following parameters: pressure, fluid flow and level, neutron flux, temperature, component status, water chemistry, electrical, and process and area radiation. The basic types of monitoring devices common to nearly all NPP control rooms include: analog meters, graphic recorders, digital displays and counters, light indicators, visual and audio alarms, and cathode-ray tubes.

  17. PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED INTO A DWELLING

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    PERFORMANCE EVALUATION OF AN AIR-TO-AIR HEAT PUMP COUPLED WITH TEMPERATE AIR-SOURCES INTEGRATED.peuportier@mines-paristech.fr, Tel.: +33 1 40 51 91 51 ABSTRACT An inverter-driven air-to-air heat pump model has been developped capacity air-to-air heat pump coupled with temperate air sources (crawlspace, attic, sunspace, heat

  18. air traffic the polytechnic school

    E-Print Network [OSTI]

    air traffic management the polytechnic school innovation.asu.edu #12;undergraduate degree program B.S., air traffic management Our undergraduate air traffic management program offers students exceptional training and state-of-the-art air traffic control simulators to enhance and reinforce classroom study. You

  19. Building America Case Study: Evaluating Through-Wall Air Transfer Fans, Pittsburgh, Pennsylvania (Fact Sheet), Whole-House Solutions for New Homes, Energy Efficiency & Renewable Energy (EERE)

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum Based Fuels ResearchofDerivativeCold Climate Foundation WallConway

  20. 2014-10-27 Issuance: Test Procedure for Ceiling Fan Light Kits; Notice of

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t y A s s iof1 of 8 2 of 8 3 of 8AirResidential

  1. Measurement of Turbulent Flame Speeds of Hydrogen and Natural Gas Blends (C1-C5 Alkanes) using a Newly Developed Fan-Stirred Vessel 

    E-Print Network [OSTI]

    Ravi, Sankaranarayana

    2014-05-06

    A fan-stirred flame speed vessel was developed at Texas A&M University to conduct turbulent combustion studies. Four high-speed impellers were installed in a central-symmetric pattern at the central circumference of an existing cylindrical laminar...

  2. Fan and Pad Greenhouse Evaporative Cooling Systems1 R. A. Bucklin, J. D. Leary, D. B. McConnell, and E. G. Wilkerson2

    E-Print Network [OSTI]

    Hill, Jeffrey E.

    CIR1135 Fan and Pad Greenhouse Evaporative Cooling Systems1 R. A. Bucklin, J. D. Leary, D. B. Mc systems. Such high temperatures reduce crop quality and worker productivity. Evaporative cooling temperatures are important when dealing with evaporative cooling systems ­ dry bulb temperature and wet bulb

  3. Groundwater Reactive Transport Models, 2012, 141-159 141 Fan Zhang, Gour-Tsyh (George) Yeh, Jack C. Parker and Xiaonan Shi (Eds)

    E-Print Network [OSTI]

    Mills, Richard

    Groundwater Reactive Transport Models, 2012, 141-159 141 Fan Zhang, Gour-Tsyh (George) Yeh, Jack C--simulating groundwater flow and solute transport, with basic chemical reactions such as aqueous complexing, mineral systems [1]. Although these simplified groundwater models are still in wide use, advances in subsurface

  4. Tunable Fresnel lens using nanoscale polymer-dispersed liquid crystals Hongwen Ren, Yun-Hsing Fan, and Shin-Tson Wua)

    E-Print Network [OSTI]

    Wu, Shin-Tson

    Tunable Fresnel lens using nanoscale polymer-dispersed liquid crystals Hongwen Ren, Yun-Hsing Fan May 2003; accepted 27 June 2003 An electrically tunable Fresnel zone plate lens is demonstrated using by voltage. The major advantages of such a Fresnel lens are simple fabrication, large aperture size

  5. Design for an inexpensive but effective cochlear implant BLAKES.WILSON,STEPHENREBSCHER,FAN-GANGZENG,ROBERTV.SHANNON,GERALDE.LOEB,DEWEYT.LAWSON,and

    E-Print Network [OSTI]

    Meng, Ellis

    monopolar electrodes. All implanted components are passive, reducing to a minimum the complexity(Rebscher),the University of California at San Francisco;the House Ear Institute (Zeng and Shannon);and the Bio Symposiumon Cochlear Implants and Linguistics,Zhengzhou,China,Oct.25-28, 1993. Reprintrequests:Fan-GangZeng,PhD,House

  6. Compressed air energy storage system

    DOE Patents [OSTI]

    Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

    1981-01-01

    An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

  7. A computerized main control room for NPP: Development and investigation

    SciTech Connect (OSTI)

    Anokhin, A. N.; Marshall, E. C.; Rakitin, I. D.; Slonimsky, V. M.

    2006-07-01

    An ergonomics assessment of the control room at Leningrad Nuclear Power Plant has been undertaken as part of an international project funded by the EU TACIS program. The project was focused on the upgrading of the existing control facilities and the installation of a validation facility to evaluate candidate refurbishment proposals before their implementation at the plant. The ergonomics methodology applied in the investigation was wide ranging and included an analysis of reported events, extensive task analysis (including novel techniques) and validation studies using experienced operators. The paper addresses the potential difficulties for the human operator associated with fully computerized interfaces and shows how the validation facility and the outcomes from ergonomics assessment will be used to minimise any adverse impact on performance that may be caused by proposed control room changes. (authors)

  8. Room-temperature magnetoelectric multiferroic thin films and applications thereof

    DOE Patents [OSTI]

    Katiyar, Ram S; Kuman, Ashok; Scott, James F.

    2014-08-12

    The invention provides a novel class of room-temperature, single-phase, magnetoelectric multiferroic (PbFe.sub.0.67W.sub.0.33O.sub.3).sub.x (PbZr.sub.0.53Ti.sub.0.47O.sub.3).sub.1-x (0.2.ltoreq.x.ltoreq.0.8) (PFW.sub.x-PZT.sub.1-x) thin films that exhibit high dielectric constants, high polarization, weak saturation magnetization, broad dielectric temperature peak, high-frequency dispersion, low dielectric loss and low leakage current. These properties render them to be suitable candidates for room-temperature multiferroic devices. Methods of preparation are also provided.

  9. Optimal Outside Air Control for Air Handling Units with Humidity Control 

    E-Print Network [OSTI]

    Wang, G.; Liu, M.

    2006-01-01

    Most air handling units (AHUs) in commercial buildings have the (air) economizer cycle to use outside air for free cooling under certain outside air conditions. Ideally the economizer cycle is enabled if outside air enthalpy is less than return air...

  10. Portable air monitoring laboratories

    SciTech Connect (OSTI)

    Ehntholt, D.J.; Beltis, K.J.; McCullough, J.E.; Valentine, J.R. [Arthur D. Little, Inc., Cambridge, MA (United States)

    1995-12-31

    Arthur D. Little, Inc. was contracted by the US Army to design, fabricate, test and deliver a series of portable air monitoring laboratories which could be used to detect trace levels of toxic chemicals on board cargo ships. The labs were designed to be completely self-sufficient, containing all supplies necessary for a 75-day mission, and to operate under rugged conditions. They were used to monitor for parts-per-billion concentrations of chemical agents in air and to provide information equivalent to high quality fixed laboratory analyses. The mission was successfully completed; independent design awards were received for the laboratories, and they were subsequently diverted to other uses.

  11. Room-temperature Formation of Hollow Cu2O Nanoparticles

    SciTech Connect (OSTI)

    Hung, Ling-I; Tsung, Chia-Kuang; Huang, Wenyu; Yang, Peidong

    2010-01-18

    Monodisperse Cu and Cu2O nanoparticles (NPs) are synthesized using tetradecylphosphonic acid as a capping agent. Dispersing the NPs in chloroform and hexane at room temperature results in the formation of hollow Cu2O NPs and Cu@Cu2O core/shell NPs, respectively. The monodisperse Cu2O NPs are used to fabricate hybrid solar cells with efficiency of 0.14percent under AM 1.5 and 1 Sun illumination.

  12. Dorm Room Idea Now Revolutionizing Energy | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum Based| Department8,Department of2 Federal Register / Vol.DollarDorm Room Idea

  13. Decoherence-Assisted Single Electron Trapping at Room Temperature

    E-Print Network [OSTI]

    Halawany, Ahmed El

    2011-01-01

    We consider the problem of single-electron tunneling through a nanowire (NW) made of a semiconductor quantum dot heterostructure at room temperature. We show that by applying a bias voltage across five quantum dots (QDs) and a gate voltage to the central QD to tune it in and out of resonance with respect to the other QDs it is possible to take advantage of a subtle combination of resonant tunneling, Coulomb blockade, Pauli exclusion principle, and decoherence effects to trap a single electron inside the central QD at room temperature. For calculating the decoherence-assisted quantum dynamics through the NW, we make use of a generalized master equation based on a Hamiltonian describing the tunneling of the electron among the QDs in the tight-binding approximation. We demonstrate that the decoherence, which is in the pico-second regime, is essential to trap the electron in the central QD with probability of 70% in 1 ps at room temperature. Our results can be used for future high-temperature single-photon source...

  14. Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York)

    Broader source: Energy.gov [DOE]

    These regulations establish emissions limits and permitting and operational requirements for facilities that may contribute to air emissions. General air quality standards and standards for...

  15. Air Charter Services

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity of Natural GasAdjustmentsShirleyEnergyTher i n c i p a l De p u t y A sCOLONYDepartment of Energy with7:00AM EST9 Room2

  16. FRAMEWORK AND APPLICATION FOR MODELING CONTROL ROOM CREW PERFORMANCE AT NUCLEAR POWER PLANTS

    SciTech Connect (OSTI)

    Ronald L Boring; David I Gertman; Tuan Q Tran; Brian F Gore

    2008-09-01

    This paper summarizes an emerging project regarding the utilization of high-fidelity MIDAS simulations for visualizing and modeling control room crew performance at nuclear power plants. The key envisioned uses for MIDAS-based control room simulations are: (i) the estimation of human error associated with advanced control room equipment and configurations, (ii) the investigative determination of contributory cognitive factors for risk significant scenarios involving control room operating crews, and (iii) the certification of reduced staffing levels in advanced control rooms. It is proposed that MIDAS serves as a key component for the effective modeling of cognition, elements of situation awareness, and risk associated with human performance in next generation control rooms.

  17. Advantages of enhanced synchronous motors in heating, refrigerating, and air conditioning applications

    SciTech Connect (OSTI)

    Morash, R.T. [Precise Power Corp., Bradenton, FL (United States)

    1998-12-31

    A new synchronous motor is a high-efficiency AC machine that has a low starting current. It may be used for conventional loads and also to start high inertia loads, delivering a constant torque during starting. Acceleration to synchronous speed can be allowed to take several minutes, if necessary, because the low starting current precludes excessive heating in the motor. Some of these motors are constructed with integral high inertia rotors that act as flywheels. These synchronous motors can ride through power sags and interruptions up to 30 seconds or more while still delivering useful load to pumps, fans, blowers, and compressors. The motors also restart instantly and resynchronize when utility power recovers. The motor can be useful in many heating, ventilating, and air-conditioning (HVAC) applications including those where machines and processes might otherwise be forced to shut down during momentary power interruptions.

  18. Canned Air in China

    E-Print Network [OSTI]

    Hacker, Randi

    2013-10-23

    Broadcast Transcript: Not that long ago, coal smoke made the air here in Beijing so caustic that your nasal passages were seared with each breath. Those were the good old days: Car ownership was limited to government officials and the rest...

  19. Zach Harmon Air Chemistry

    E-Print Network [OSTI]

    Toohey, Darin W.

    in the Troposphere Summary of Problem/Impact United States dependency on foreign oil and increased energy consumptionZach Harmon 810907207 Air Chemistry Natural Gas Production Impacts on levels of ozone administration to encourage fast growth to reduce dependency of foreign oil and be energy independent. It

  20. Compressed Air 101: Getting Compressed Air to Work 

    E-Print Network [OSTI]

    Burke, J. J.; Bessey, E. G.

    2003-01-01

    "Air compressors are a significant industrial energy user. Based on a survey (conducted by Oregon State University and the Bonneville Power Administration) of energy audit reports from 125 plants, air compressors account for roughly 10% of total...

  1. Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont)

    Broader source: Energy.gov [DOE]

    The ambient air quality standards are based on the national ambient air quality standards. The Vermont standards are classified as primary and secondary standards and judged adequate to protect...

  2. Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics 

    E-Print Network [OSTI]

    Graham, E. L.

    1980-01-01

    Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

  3. 3-50 A classroom is to be air-conditioned using window air-conditioning units. The cooling load is due to people, lights, and heat transfer through the walls and the windows. The number of 5-kW window air

    E-Print Network [OSTI]

    Bahrami, Majid

    3-19 3-50 A classroom is to be air-conditioned using window air-conditioning units. The cooling.17 3-51 The lighting energy consumption of a storage room is to be reduced by installing motion sensors lamps)(60 W/lamp )(3285 hours/year) = 4730 kWh/year Cost Savings = (Energy Savings)(Unit cost of energy

  4. The investigation of exhaust powered, automotive air cycle air conditioning 

    E-Print Network [OSTI]

    Holley, James Andrew

    1978-01-01

    TEE INVESTIGATION OF EXHAUST POWERED, AUTOMOTIVE AIR CYCLE AIR CONDITIONING A Thesis James Andrew Holley Submitted to the Graduate College of Texas ASM University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE... August 1978 Major SubJect: Mechanical Engineering THE INVESTIGATION OF EXHAUST POWERED, AUTOMOTIVE AIR CYCLE AIR CONDITIONING A Thesis hy James Andrew Holley Approved as to style and content by: Chairman of Committee) (Head of Departm nt) Memb e...

  5. Energy and air quality implications of passive stack ventilation in residential buildings

    SciTech Connect (OSTI)

    Mortensen, Dorthe Kragsig; Walker, Iain S.; Sherman, Max

    2011-01-01

    Ventilation requires energy to transport and condition the incoming air. The energy consumption for ventilation in residential buildings depends on the ventilation rate required to maintain an acceptable indoor air quality. Historically, U.S. residential buildings relied on natural infiltration to provide sufficient ventilation, but as homes get tighter, designed ventilation systems are more frequently required particularly for new energy efficient homes and retrofitted homes. ASHRAE Standard 62.2 is used to specify the minimum ventilation rate required in residential buildings and compliance is normally achieved with fully mechanical whole-house systems; however, alternative methods may be used to provide the required ventilation when their air quality equivalency has been proven. One appealing method is the use of passive stack ventilation systems. They have been used for centuries to ventilate buildings and are often used in ventilation regulations in other countries. Passive stacks are appealing because they require no fans or electrical supply (which could lead to lower cost) and do not require maintenance (thus being more robust and reliable). The downside to passive stacks is that there is little control of ventilation air flow rates because they rely on stack and wind effects that depend on local time-varying weather. In this study we looked at how passive stacks might be used in different California climates and investigated control methods that can be used to optimize indoor air quality and energy use. The results showed that passive stacks can be used to provide acceptable indoor air quality per ASHRAE 62.2 with the potential to save energy provided that they are sized appropriately and flow controllers are used to limit over-ventilation.

  6. Performance Evaluation of Radiant Cooling System Integrated with Air System under Different Operational Strategies

    SciTech Connect (OSTI)

    Khare, Vaibhav [Malaviya National Institute of Technology (MNIT), Jaipur, India; Khan, Yasin [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    The paper describes a parametric study developed to estimate the energy savings potential of a radiant cooling system installed in a commercial building in India. The study is based on numerical modeling of a radiant cooling system installed in an Information Technology (IT) office building sited in the composite climate of Hyderabad. To evaluate thermal performance and energy consumption, simulations were carried out using the ANSYS FLUENT and EnergyPlus softwares, respectively. The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption of a building using a conventional all-air system to determine the proportional energy savings. For proper handling of the latent load, a dedicated outside air system (DOAS) was used as an alternative to Fan Coil Unit (FCU). A comparison of energy consumption calculated that the radiant system was 17.5 % more efficient than a conventional all-air system and that a 30% savings was achieved by using a DOAS system compared with a conventional system. Computational Fluid Dynamics (CFD) simulation was performed to evaluate indoor air quality and thermal comfort. It was found that a radiant system offers more uniform temperatures, as well as a better mean air temperature range, than a conventional system. To further enhance the energy savings in the radiant system, different operational strategies were analyzed based on thermal analysis using EnergyPlus. The energy savings achieved in this parametric run were more than 10% compared with a conventional all-air system.

  7. Environmental Pollution Air Pollution Dispersion Practical Air Pollution Dispersion

    E-Print Network [OSTI]

    Moncrieff, John B.

    Environmental Pollution Air Pollution Dispersion 1 of 5 Practical ­ Air Pollution Dispersion in the lectures how such models can be used to explain observed concentrations of air pollutants in an area and to test `what-if' scenarios for pollution control and reduction. You will use the Gaussian Plume Model

  8. Social Media: Air Quality #SummerSafety

    E-Print Network [OSTI]

    than adults to the health effects caused by air pollution. http://cdc.gov/air/air_health.htm #SummerSafety Twitter: Children and teens may be more sensitive than adults to air pollution. http://cdc.gov/air/air Social Media: Air Quality #SummerSafety Please help the NWS spread these important safety

  9. Environmental continuous air monitor for ambient transuranic particulates

    SciTech Connect (OSTI)

    Rodgers, J.C.; Moore, M.E. [Los Alamos National Lab., NM (United States)

    1995-12-31

    We have constructed a working prototype of an environmental continuous air monitor (ECAM) for outdoor applications. The ECAM device is designed to continuously monitor the presence of transuranic contaminant aerosol below a size of 10 mm aerodynamic diameter. In remote operation, the ECAM can transmit radiological and meteorological data to a central processing location, where we have implemented geographical mapping and GPS capabilities into an integrated software package. The Canberra Alpha Sentry Monitor, a commercially available continuous air monitor (CAM) for indoor room applications, was used as the basic building block for the prototype. We increased the sample air flow to 4 cubic feet per minute (CFM) compared to the design air flow rate of 2 CFM. We also added a spread-spectrum radio data link between the CAM RS-232 serial port and a distant radio receiver that enables remote monitoring. In order to avoid collecting the large diameter particle fraction containing most of the inert mass that causes sample burial and alpha spectrum degradation, a Model 254 PM10 size-fractionating Wet from Graseby-Andersen was fitted to the Alpha Sentry Monitor. We removed the top cover of the CAM unit, and routed openings in the top surface of the CAM inlet. This allows air to flow into the inlet, down a collection tube, and then vertically into the CAM without the elbow and horizontal transition piece of the present in-line adapter. The air flows through a 47 mm filter, and the transuranic contamination is counted by a solid state alpha radiation detector, which is placed at a distance of 5 mm above the filter. The increased air flow significantly improves CAM alarm sensitivity and response time to an estimated level of 3.8x10-12 mCi/ml for an integration period 30 minutes. At the same time, the fractionating inlet removes a substantial amount of inert dust and thus enables extended monitoring without frequent maintenance.

  10. Crews Make First Entry into McCluskey Room for Final Cleanup at Hanford Site

    Office of Energy Efficiency and Renewable Energy (EERE)

    RICHLAND, Wash. – Workers are cleaning up one of the most hazardous rooms at the Hanford site: the “McCluskey Room,” named after a worker who was injured there in a Cold War accident.

  11. Optimization of Air Conditioning Cycling 

    E-Print Network [OSTI]

    Seshadri, Swarooph

    2012-10-19

    Systems based on the vapor compression cycle are the most widely used in a variety of air conditioning applications. Despite the vast growth of modern control systems in the field of air conditioning systems, industry standard control is still...

  12. Tennessee Air Quality Act (Tennessee)

    Broader source: Energy.gov [DOE]

    The Tennessee Air Quality Act (AQA) delegates the power to maintain air quality in the State to the Department of Environment and Conservation. Under the Department of the Environment and...

  13. Louisiana Air Control Law (Louisiana)

    Broader source: Energy.gov [DOE]

    This law states regulations for air quality control and states the powers and duties of the secretary of environmental quality. It provides information about permits and licenses, air quality...

  14. Fundamentals of Compressed Air Systems

    Office of Energy Efficiency and Renewable Energy (EERE)

    Find out how a compressed air system works and the benefits of optimal compressed air system performance. This initial class demonstrates how to compute the current cost of your plant's compressed...

  15. Quantitative room-temperature mineralization of airborne formaldehyde using manganese oxide catalysts

    E-Print Network [OSTI]

    Sidheswaran, Meera A.

    2012-01-01

    temperature thermo-catalytic oxidation reactor. Proceedingsarea. Room temperature catalytic oxidation of airborneand their catalytic activity for formaldehyde oxidation.

  16. Air Pollution & Health in Rapidly Developing Countries

    E-Print Network [OSTI]

    Bucher, Scott

    2005-01-01

    Review: Air Pollution & Health in Rapidly DevelopingFrank Murray (Eds. ). Air Pollution & Health in Rapidlyand researchers alike, Air Pollution & Health provides a

  17. Radionuclide Air Emission Report for 2011

    E-Print Network [OSTI]

    Wahl, Linnea

    2012-01-01

    LBNL-470E-20Ì1 Radionuclide Air Emission Report for Preparedfor Estimating Fugitive Air Emissions of Radionuclides fromStandards for Hazardous Air Pollutants (Radionuclides),

  18. COMBUSTION-GENERATED INDOOR AIR POLLUTION

    E-Print Network [OSTI]

    Hollowell, C.D.

    2011-01-01

    The Japanese Union of Air Pollution Prevention Associations,The Status of Indoor Air Pollution Research 1976, GeometAnnual Meeting of the Air Pollution Control Association,

  19. COMBUSTION-GENERATED INDOOR AIR POLLUTION

    E-Print Network [OSTI]

    Hollowell, C.D.

    2011-01-01

    Ext. 6782 Combustion -Generated Indoor Air Pollution Craigcontrol of air pollution from indoor combustion sources. Ifocused on combustion-generated indoor air pollution, namely

  20. Air Observe System

    E-Print Network [OSTI]

    Alexander Bolonkin

    2007-01-10

    This manuscript contains a description and basic principles for observing inaccessible areas using low cost, easily deployed equipment. The basic premise is to suspend a tiny video camera at an altitude of 10 - 200 meters over the area to be surveyed. The TV camera supports at altitude by wind or balloon. The technical challenges regard the means by which the camera is suspended. Such a system may be used by military or police forces or by civil authorities for rescue missions or assessment of natural disasters. The method may be further developed for military applications by integrating the surveillance task with deployment of munitions. Key words: air observer, air suspended system, low altitude video observer.