Variable Speed Fan Retrofits for Computer Room Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

Variable-Speed Fan Retrofits for Computer-Room Air Conditioners Prepared for the U.S. Department of Energy Federal Energy Management Program Technology Case Study Bulletin By...

2

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Variable-Speed Fan Variable-Speed Fan Retrofits for Computer-Room Air Conditioners Prepared for the U.S. Department of Energy Federal Energy Management Program Technology Case Study Bulletin By Lawrence Berkeley National Laboratory Steve Greenberg September 2013 2 Contacts Steve Greenberg Lawrence Berkeley National Laboratory One Cyclotron Road, 90R3111 Berkeley, California 94720 (510) 486-6971 segreenberg@lbl.gov For more information on FEMP, please contact: Will Lintner, P.E., CEM Federal Energy Management Program U.S. Department of Energy 1000 Independence Ave. S.W. Washington, D. C. 20585-0121 (202) 586-3120 william.lintner@ee.doe.gov 3 Acknowledgements EPRI: Dennis Symanski, Brian Fortenbery Synapsense: Garret Smith, Patricia Nealon Vigilent: Corinne Vita

3

Demonstration of Intelligent Control and Fan Improvements in Computer Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Demonstration of Intelligent Control and Fan Improvements in Computer Room Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers Title Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers Publication Type Report Refereed Designation Unknown LBNL Report Number LBNL-6007E Year of Publication 2012 Authors Coles, Henry C., Steve E. Greenberg, and Corrine Vita Document Number LBNL-6007E Date Published 12/2012 Publisher Lawrence Berkeley National Laboratory City Berkeley, CA Keywords air distribution, building technology and urban systems department, computer room air handler, crah control, data center, data center crah, ec fan, ecm, ecm fan, fan speed control, high tech and industrial systems group, plug fan, variable frequency drive, vfd, wireless control Abstract

4

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

you need to mount the air conditioner at the narrow end of a long room, then look for a fan control known as "Power Thrust" or "Super Thrust" that sends the cooled air farther...

5

Room Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

of Superefficient Room Air Conditioners year month keywords appliance energy efficiency energy efficiency incentives Market Transformation standards url https isswprod lbl gov...

6

Supply Fan Control for Constant Air Volume Air Handling Units  

E-Print Network (OSTI)

Since terminal boxes do not have a modulation damper in constant volume (CV) air handling unit (AHU) systems, zone reheat coils have to be modulated to maintain the space temperature with constant supply airflow. This conventional control sequence causes a significant amount of reheat and constant fan power under partial load conditions. Variable Frequency Drives (VFDs) can be installed on these constant air volume systems. The fan speed can be modulated based on the maximum zone load. This paper present the procedure to control the supply fan speed and analyzes the thermal performance and major fan energy and thermal energy savings without expensive VAV retrofit through the actual system operation.

Cho, Y.; Wang, G.; Liu, M.

2007-01-01T23:59:59.000Z

7

Fans for Cooling | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fans for Cooling Fans for Cooling Fans for Cooling May 30, 2012 - 7:46pm Addthis Ceiling fans circulate air in a room to help keep occupants cool. | Photo courtesy of ©iStockphoto/jimkruger Ceiling fans circulate air in a room to help keep occupants cool. | Photo courtesy of ©iStockphoto/jimkruger What does this mean for me? You may be able to keep your home cool with energy-efficient and well-placed fans. Fans are less expensive to operate than air conditioners. Circulating fans include ceiling fans, table fans, floor fans, and fans mounted to poles or walls. These fans create a wind chill effect that will make you more comfortable in your home, even if it's also cooled by natural ventilation or air conditioning. Ceiling Fans Ceiling fans are considered the most effective of these types of fans,

8

Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration  

E-Print Network (OSTI)

Using Mechanical Ventilation Exhaust Fans Air-to-Air Heatexpected from exhaust fan A-I Infiltration contribution toIndoor Air Quality -- Exhaust Fan Mitigation" Final Report

Grimsrud, David T.

2009-01-01T23:59:59.000Z

9

Choosing the right boiler air fans at Weston 4  

SciTech Connect

When it came to choosing the three 'big' boiler air fans - forced draft, induced draft and primary air, the decision revolved around efficiency. The decision making process for fan selection for the Western 4 supercritical coal-fired plant is described in this article. 3 photos.

Spring, N.

2009-04-15T23:59:59.000Z

10

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Room Air Conditioners July 1, 2012 - 5:35pm Addthis A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. What does this mean for me? Room air conditioners are less expensive and disruptive to install than central air conditioning systems. Room air conditioners can be a cost-effective alternative to central air conditioning systems. How does it work? Room air conditioners work by cooling one part of your home. Room or window air conditioners cool rooms rather than the entire home or business. If they provide cooling only where they're needed, room air conditioners are less expensive to operate than central units, even though

11

Enabling Energy-Efficient Approaches to Thermal Comfort Using Room Air Motion  

E-Print Network (OSTI)

that almost all the configuration with fan (except the twovelocity level 3 oscillating-fan configurations) performedto the configuration without fan. Air Quality Acceptance

Pasut, Wilmer; Arens, Edward; Zhang, Hui; Kaam, Soazig; Zhai, Yongchao

2013-01-01T23:59:59.000Z

12

Characterization of air recirculation in multiple fan ventilation systems.  

E-Print Network (OSTI)

??Booster fans, large underground fans, can increase the volumetric efficiency of ventilation systems by helping to balance the pressure and quantity distribution throughout a mine, (more)

Wempen, Jessica Michelle

2012-01-01T23:59:59.000Z

13

Perimeter fan performance in forced draught air-cooled steam condensers.  

E-Print Network (OSTI)

??ENGLISH ABSTRACT: Axial flow fan arrays form part of air-cooled steam condensers in direct drycooled power plants. This dissertation investigates the performance of axial flow (more)

Van der Spuy, Sybrand Johannes

2011-01-01T23:59:59.000Z

14

Room air monitor for radioactive aerosols  

DOE Patents (OSTI)

A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-pre The U.S. Government has rights in this invention pursuant to Contract No. DE-AC04-76DP03533 between the Department of Energy and Rockwell International Corporation.

Balmer, David K. (Broomfield, CO); Tyree, William H. (Boulder, CO)

1989-04-11T23:59:59.000Z

15

Room air monitor for radioactive aerosols  

DOE Patents (OSTI)

A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-preamplifier combination. 2 figs.

Balmer, D.K.; Tyree, W.H.

1987-03-23T23:59:59.000Z

16

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and unnecessary expense. Set the fan speed on high, except on very humid days. When humidity is high, set the fan speed on low for more comfort. The low speed on humid days will...

17

Performance Analysis of Dual-Fan, Dual-Duct Constant Volume Air-Handling Units  

E-Print Network (OSTI)

Dual-fan, dual-duct air-handling units introduce outside air directly into the cooling duct and use two variable speed devices to independently maintain the static pressure of the hot and the cold air ducts. Analytical models have been developed to compare fan power and thermal energy consumption of dualfan, dual-duct constant volume air-handling units with single-fan, dual-duct constant volume airhandling units. This study shows that the dual-fan, dual-duct system uses less fan power and less thermal energy during winter, and uses more thermal energy during summer. Thermal energy performance can be significantly improved if the thermal energy penalty can be decreased or eliminated.

Joo, I. S.; Liu, M.

2001-01-01T23:59:59.000Z

18

Federal Energy Management Program: Covered Product Category: Room Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioners to someone by E-mail Room Air Conditioners to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Google Bookmark Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Delicious Rank Federal Energy Management Program: Covered Product Category: Room Air Conditioners on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Room Air Conditioners on AddThis.com... Energy-Efficient Products Federal Requirements Covered Product Categories Product Designation Process

19

Evaluation of Energy-Efficiency Standards for Room Air Conditioners...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy-Efficiency Standards for Room Air Conditioners in the US Title Evaluation of Energy-Efficiency Standards for Room Air Conditioners in the US Publication Type Journal Article...

20

EVALUATION OF TRANSITIONS FOR TESTING AGRICULTURAL VENTILATION FANS WITH THE FAN ASSESSMENT NUMERATION SYSTEM (FANS).  

E-Print Network (OSTI)

??The Fan Assessment Numeration System (FANS) is an improved air velocity traverse method for measuring in situ fan performance. The FANS has been widely used, (more)

Lopes, Igor Moreira

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Enabling Energy-Efficient Approaches to Thermal Comfort Using Room Air Motion  

E-Print Network (OSTI)

Energy Efficiency, Thermal Comfort with Air MotionEnergy Efficiency, Thermal Comfort with Air Motion No-fan 2Energy Efficiency, Thermal Comfort with Air Motion

Pasut, Wilmer; Arens, Edward; Zhang, Hui; Kaam, Soazig; Zhai, Yongchao

2013-01-01T23:59:59.000Z

22

Variable Speed Fan Retrofits for Computer Room Air Conditioners  

Energy.gov (U.S. Department of Energy (DOE))

Case study describes various concepts for more cost-effective cooling solutions in data centers, while keeping in mind that the reliability of computing systems and their respective cooling systems is always a key criterion.

23

Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration  

E-Print Network (OSTI)

Fans Air-to-Air Heat Exchangers. . . . . . . . . . . . . . .expected from heat exchangers Ventilation expected fromventilation supplied by heat exchanger and exhaust flow. .

Grimsrud, David T.

2009-01-01T23:59:59.000Z

24

Tritium Room Air Monitor Operating Experience Review  

SciTech Connect

Monitoring the breathing air in tritium facility rooms for airborne tritium is a radiological safety requirement and a best practice for personnel safety. Besides audible alarms for room evacuation, these monitors often send signals for process shutdown, ventilation isolation, and cleanup system actuation to mitigate releases and prevent tritium spread to the environment. Therefore, these monitors are important not only to personnel safety but also to public safety and environmental protection. This paper presents an operating experience review of tritium monitor performance on demand during small (1 mCi to 1 Ci) operational releases, and intentional airborne inroom tritium release tests. The tritium tests provide monitor operation data to allow calculation of a statistical estimate for the reliability of monitors annunciating in actual tritium gas airborne release situations. The data show a failure to operate rate of 3.5E-06/monitor-hr with an upper bound of 4.7E-06, a failure to alarm on demand rate of 1.4E-02/demand with an upper bound of 4.4E-02, and a spurious alarm rate of 0.1 to 0.2/monitor-yr.

L. C. Cadwallader; B. J. Denny

2008-09-01T23:59:59.000Z

25

Building Energy Software Tools Directory: Room Air Conditioner Cost  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioner Cost Estimator Room Air Conditioner Cost Estimator Screen capture of Room Air Conditioner Cost Estimator The cost estimator compares high-efficiency room air conditioners to standard equipment in terms of life cycle cost. It provides an alternative to complicated building simulation models, while offering more precision than simplified estimating tools that are commonly available. The cost estimator assists decision-making regarding the purchase or replacement of room air conditioning equipment, by estimating a product�s lifetime energy cost savings at various efficiency levels. Screen Shots Keywords air conditioner, life-cycle cost, energy performance, residential buildings, energy savings Validation/Testing Internal reviews at Pacific Northwest National Laboratory.

26

ENERGY STAR Qualified Room Air Conditioners | Data.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Room Air Conditioners Room Air Conditioners Consumer Data Apps Challenges Resources About Blogs Let's Talk Feedback Consumer You are here Data.gov » Communities » Consumer » Data ENERGY STAR Qualified Room Air Conditioners Dataset Summary Description Room Air Conditioners that have earned the ENERGY STAR are more efficient than standard models. ENERGY STAR is the trusted symbol for energy efficiency helping consumers save money and protect the environment through energy-efficient products and practices. More information on ENERGY STAR is available at www.energystar.gov. Tags {"Room Air Conditioners","Energy Star",products,"energy efficiency",efficient,"greenhouse gas emissions",climate,utility,utilities,household,savings,labels,partners,certification}

27

Monitoring radioactive xenon gas in room air using activated charcoal  

SciTech Connect

A method for monitoring room air for radioactive xenon gas is described. It uses activated charcoal vials, a vacuum source and a well-type scintillation counter. The method may be adapted for detection and identification of any radioactive gas excluding those with ultra-short half-lives. Sampling room air during xenon-133 ({sup 133}Xe) ventilation lung studies was performed using this technique. The results show that low concentrations of {sup 133}Xe in room air can be reliably detected and that staff exposure to {sup 133}Xe at this institution was within ICRP recommendations.

Langford, J.; Thompson, G. (Princess Margaret Hospital for Children, Perth (Australia) Sir Charles Gairdner Hospital, Perth (Australia))

1990-03-01T23:59:59.000Z

28

Covered Product Category: Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Covered Product Category: Room Air Conditioners October 7, 2013 - 10:40am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

29

Covered Product Category: Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Covered Product Category: Room Air Conditioners October 7, 2013 - 10:40am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including room air conditioners, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

30

Five ENERGY STAR Room Air Conditioners Fail Testing  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy's Office of Enforcement announced today that DOE testing has identified five Friedrich room air conditioners that do not meet the ENERGY STAR Programs energy...

31

Improving Control of a Dual-Duct Single-Fan Variable Air Volume Systems  

E-Print Network (OSTI)

This paper discusses improved control strategies for dual-duct single-fan variable air volume (VAV) systems. Common control strategy for supply air volume modulation is evaluated, and an improved air volume control strategy that maintains separate cold and hot air duct static pressure set points is presented. The paper also explores the interactions between the cold and hot deck temperatures and duct static pressures, and discusses the impact of non-ideal deck temperature settings on duct static pressures and overall system energy consumption. To compensate the negative impact of non-ideal cold and hot deck temperature set points, the authors propose using real-time duct static pressure readings as feedback signals to fine-tune the deck temperature set points. These new control schemes can reduce simultaneous cooling and heating while reducing fan power consumption.

Wei, G.; Martinez, J.; Minihan, T.; Brundidge, T.; Claridge, D. E.; Turner, W. D.

2003-01-01T23:59:59.000Z

32

Guidelines for Induced Flue Gas Recirculation: Volume 1: Reducing Air/Gas System Resistance and Enhancing Fan Capacity  

Science Conference Proceedings (OSTI)

This document guides users through a logical sequence, or "road map," of activities and decisions for optimizing solutions for fans, ducts, and related equipment in fossil plant combustion air and gas systems.

1999-12-13T23:59:59.000Z

33

List of Room Air Conditioners Incentives | Open Energy Information  

Open Energy Info (EERE)

Conditioners Incentives Conditioners Incentives Jump to: navigation, search The following contains the list of 112 Room Air Conditioners Incentives. CSV (rows 1 - 112) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility Nonprofit Schools State Government Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Room Air Conditioners Yes Alexandria Light and Power - Residential Energy Efficiency Rebate Program (Minnesota) Utility Rebate Program Minnesota Residential Central Air conditioners

34

Room Air Conditioning Energy Efficiency and Demand Response Potential  

Science Conference Proceedings (OSTI)

Room or window air conditioners are a common appliance in parts of the United States residential sector for providing summertime cooling. The technology is based on the same vapor compression cycle common in central air conditioning and refrigeration applications, but with all system components in one enclosure, which is generally small and comparatively inexpensive. The systems are simple and modular enough to be installed by the homeowner, and can be installed in windows without major modification, or ...

2011-06-30T23:59:59.000Z

35

Energy Savings in Buildings Using Air Movement and Allowing Floating Temperature in Rooms  

E-Print Network (OSTI)

The purpose of the research study was to determine if building loads could be reduced by using an intelligent controller rather than a thermostatic controller to operate heating and air conditioning equipment. In order to switch the equipment on and off at the proper times, the intelligent controller calculated temperature limits using a mathematical procedure that determined the percentage of people who would be comfortable in rooms of the building. Simulations showed the annual cost savings from intelligent controllers ranged from 6 to 37 percent for residences and from 6 to 29 percent for the offices. An ancillary study showed that a ceiling fan provided comfort in a 112 square foot floor area to 85 F and in a 200 to 250 square foot area to 82 F.

Spain, S.

1985-01-01T23:59:59.000Z

36

List of Whole House Fans Incentives | Open Energy Information  

Open Energy Info (EERE)

Whole House Fans Incentives Whole House Fans Incentives Jump to: navigation, search The following contains the list of 26 Whole House Fans Incentives. CSV (rows 1 - 26) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Alliant Energy Interstate Power and Light (Gas and Electric) - Farm Equipment Energy Efficiency Incentives (Iowa) Utility Rebate Program Iowa Agricultural Agricultural Equipment Ceiling Fan Clothes Washers Custom/Others pending approval Dishwasher Doors Heat recovery Lighting Motor VFDs Motors Refrigerators Water Heaters Windows Whole House Fans Room Air Conditioners Ground Source Heat Pumps Yes Alliant Energy Interstate Power and Light - Farm Equipment Energy Efficiency Incentives (Minnesota) Utility Rebate Program Minnesota Agricultural Agricultural Equipment

37

Energy Consumption Estimation for Room Air-conditioners Using Room Temperature Simulation with One-Minute Intervals  

E-Print Network (OSTI)

For the purpose of developing optimized control algorithm for room air-conditioners to ensure their energy efficiency, a short time interval (i.e., one minute) simulation of building thermal performance is necessary because the sampling time interval for room air-conditioner control is one minute in general. This paper studies the short-time interval room air temperature simulation method using the response factor method. Using the simulated room air temperature, an air-conditioner's running time can be known so that its energy consumption can be estimated accurately. In order to verify the simulation accuracy, an actual room equipped with a gas-engine heat pump (GHP) air-conditioning system is studied by both simulation and measurement. The cooling amount produced by the GHP is calculated using measured refrigerant pressure and temperature at condenser and evaporator respectively. The Root Mean Square Error (RMSE) between measured cooling amount and simulated cooling load is 18.9 percent of the average measured value. The profile of simulated room air temperature in both air-conditioned daytime and nighttime without air-conditioning can match the measured room air temperature. With respect to the estimated energy consumption, the profile of simulated energy consumption can match the measured data. The simulation accuracy of room air temperature and energy consumption during the air-conditioner start-up period is not good and needs to be improved in future research. But in general, the verification shows that this energy consumption simulation method is acceptable for evaluating the energy performance of a room air-conditioner, and can also be a useful tool for commissioning room air-conditioners.

Wang, F.; Yoshida, H.; Matsumoto, K.

2006-01-01T23:59:59.000Z

38

Development of a High Efficiency Ceiling Fan  

E-Print Network (OSTI)

The potential of ceiling fans to improve comfort during the cooling season is well documented (Rohles et al.. 1983; Fairey et al.. 1986). There are at least two cases: In the first where air conditioning is unavailable, adding ceiling fans may significantly improve building comfort and health although actually increasing energy use. However, the more common circumstance is where ceiling fans are used with the objective of providing a higher cooling system thermostat set point with acceptable comfort. Fans can also potentially avoid the use of air conditioning during "swing" seasons. Although studies commonly suggest a 2-6OF increase in the thermostat set point, data from 386 surveyed Central Florida households suggests that although fans are used an average of 13.4 hours per day, no statistically valid difference can be observed in thermostat settings between households using fans and those without them (James et al., 1996). Part of this may be due to the lack of sufficiently wide air distribution coverage within rooms (Rohles et al, 1983; Sonne and Parker, 1998). Studies touting potential cooling savings of up to 40% have usually been sponsored by fan manufacturers (eg. A.D. Little, 1981). These often make unrealistic assumptions such as presuming that occupants are within four feet of a fan with only one fan in use and a 6F elevation of the thermostat setting. An environmental chamber study by Consumer Reports showed that the long-reported de-stratification benefits when heating are largely unsubstantiated (Consumer Reports. 1993). Thus. benefits from ceiling fans are only to reduce cooling needs and this is completely contingent on sufficient changes in interior comfort to warrant raising of the cooling thermostat. Two other factors must be taken into account in assessing the benefits of fans: their actual energy use and the added internal heat gains produced by the fans during operation. The measured electrical demand of ceiling fans varies between 5 and 115 Watts depending on model and speed selection. A power demand of 40 W at medium speed is probably typical (Chandra, 1985). Thus, a fan used for six months of the year would use 175 kwh. With 4.3 ceiling fans in an average Florida home, this amounts to about 800 kwh of fan energy consumption --about 5% of total electricity use. Also, all of the energy use of fans is eventually converted to heat within the home which must eventually be removed by ventilation air or the cooling system.

Parker, D. S.; Callahan, M. P.; Sonne, J. K.; Su, G. H.; Hibbs, B. D.

2000-01-01T23:59:59.000Z

39

INFLUENCE OF FAN OPERATION ON FAN ASSESSMENT NUMERATION SYSTEM (FANS) TEST RESULTS.  

E-Print Network (OSTI)

??The use of velocity traverses to measure in-situ air flow rate of ventilation fans can be subject to significant errors. The Fan Assessment Numeration System (more)

Morello, Gabriela Munhoz

2011-01-01T23:59:59.000Z

40

Optimized Fan Control In Variable Air Volume HVAC Systems Using Static Pressure Resets: Strategy Selection and Savings Analysis  

E-Print Network (OSTI)

The potential of static pressure reset (SPR) control to save fan energy in variable air volume HVAC systems has been well documented. Current research has focused on the creation of reset strategies depending on specific system features. As the commissioning process has begun to require the prediction of savings, knowledge of the extent to which various SPR control strategies impact fan energy has become increasingly important. This research aims to document existing SPR control strategies and utilize building data and simulation to estimate fan energy use. A comprehensive review of the literature pertaining to SPR control was performed and the results were organized into a top-down flow chart tool. Based on the type of feedback available from a particular system, or lack thereof, this tool will facilitate the selection of a SPR control strategy. A field experiment was conducted on a single duct variable air volume system with fixed discharge air temperature and static pressure setpoints. Finally, an air-side model of the experimental system was created using detailed building design information and calibrated using field measurements. This model was used to estimate the fan energy required to supply the trended airflow data using fixed static pressure (FSP) and SPR control based on zone demand, system demand, and outside air temperature. While utilizing trend data from November 1, 2008 to February 12, 2009, the FSP control of the experimental system was used as the baseline for ranking the energy savings potential of nine different forms of duct static pressure control. The highest savings (73-74%) were achieved using zonal demand based SPR control. System demand based SPR control yielded savings ranging from 59 to 76%, which increased when the duct sensor was positioned near the fan discharge and under similar zone load conditions. The outside air temperature based SPR control yielded savings of 65% since the experimental system supplied primarily perimeter zones. Finally, increasing the FSP setpoint from 2 to 3 inWG increased fan energy by 45%, while decreasing the setpoint from 2 to 1 inWG decreased fan energy by 41%.

Kimla, John

2009-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Research on Thermal Properties in a Phase Change Wallboard Room Based on Air Conditioning Cold Storage  

E-Print Network (OSTI)

After comparing the thermal performance parameters of an ordinary wall room to a phase change wall (PCW) room, we learn that phase change wallboard affects the fluctuation of temperature in air-conditioning room in the summer. We built a PCW room and an ordinary wall room, which are cooled by an air-conditioner. We used differential scanning calorimetry (DSC) to test the temperature field and heat flow fluctuation in these rooms. Through analyzing the data tested, we found that the mean temperature of PCW is lower than that of ordinary wall room by 1 to 2?, and PCW can lower the heat flow by 4.6W/m2. Combining phase change material with the building envelope can lower the indoor temperature, make the room thermally comfortable, and cut down the turn-on-and-off frequency of the air-conditioner and the primary investment and operating costs. It alleviates the urgent need for electricity.

Feng, G.; Li, W.; Chen, X.

2006-01-01T23:59:59.000Z

42

Turning on the Fan and Turning off the A/C | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Turning on the Fan and Turning off the A/C Turning on the Fan and Turning off the A/C Turning on the Fan and Turning off the A/C September 20, 2010 - 3:00pm Addthis As part of some recent money- and energy-savings improvements I've been making to my home, a couple of weeks ago I installed a ceiling fan in my main living room. Chris Stewart Senior Communicator at DOE's National Renewable Energy Laboratory As part of some recent money- and energy-savings improvements I've been making to my home, a couple of weeks ago I installed a ceiling fan in my main living room. Part of my research led me to understand how ceiling fans are considered the most effective fans compared among table fans, floor fans, and fans mounted to poles or walls because they effectively circulate the air in a room to create a draft throughout the room.

43

Turning on the Fan and Turning off the A/C | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Turning on the Fan and Turning off the A/C Turning on the Fan and Turning off the A/C Turning on the Fan and Turning off the A/C September 20, 2010 - 3:00pm Addthis As part of some recent money- and energy-savings improvements I've been making to my home, a couple of weeks ago I installed a ceiling fan in my main living room. Chris Stewart Senior Communicator at DOE's National Renewable Energy Laboratory As part of some recent money- and energy-savings improvements I've been making to my home, a couple of weeks ago I installed a ceiling fan in my main living room. Part of my research led me to understand how ceiling fans are considered the most effective fans compared among table fans, floor fans, and fans mounted to poles or walls because they effectively circulate the air in a room to create a draft throughout the room.

44

Smart Fan Modules And System  

DOE Patents (OSTI)

A fan module including: two or more individual fans, each fan having an air movement means and a motor engaged with the air movement means for accelerating air entering each of the two or more individual fans; a temperature sensor for sensing a temperature associated with the two or more fans and for outputting a first signal corresponding to the temperature; rotational speed sensor for outputting a second signal corresponding to a rotational speed of each of the two or more fans; and a processor for receiving the first and second signals and controlling the two or more individual fans based on the first and second signals. A fan module including: two or more individual fans, each fan having an air movement means and a motor engaged with the air movement means for accelerating air entering each of the two or more individual fans; a temperature sensor for sensing a temperature associated with the two or more fans and for outputting a first signal corresponding to the temperature; rotational speed sensor for outputting a second signal corresponding to a rotational speed of each of the two or more fans; and a processor for receiving the first and second signals and controlling the two or more individual fans based on the first and second signals.

Cipolla, Thomas M. (Katonah, NY); Kaufman, Richard I. (Somers, NY); Mok, Lawrence S. (Brewster, NY)

2003-07-15T23:59:59.000Z

45

Effect of room air recirculation delay on the decay rate of tracer gas  

NLE Websites -- All DOE Office Websites (Extended Search)

Effect of room air recirculation delay on the decay rate of tracer gas Effect of room air recirculation delay on the decay rate of tracer gas Title Effect of room air recirculation delay on the decay rate of tracer gas Publication Type Conference Proceedings Year of Publication 2004 Authors Kristoffersen, Astrid H., Ashok J. Gadgil, and David M. Lorenzetti Conference Name 9th International Conference on Air Distribution in Rooms - RoomVent 2004, Pagination pp 6 Date Published September 5-8, 2 Conference Location Coimbra, Portugal Abstract Tracer gas measurements are commonly used to estimate the fresh air exchange rate in a room or building. Published tracer decay methods account for fresh air supply, infiltration, and leaks in ductwork. However, the time delay associated with a ventilation system recirculating tracer back to the room also affects the decay rate. We present an analytical study of tracer gas decay in a well-mixed, mechanically-ventilated room with recirculation. The analysis shows that failing to account for delays can lead to under- or over-estimates of the fresh air supply, depending on whether the decay rate calculation includes the duct volume

46

Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power and Thermal Energy - Part I: Theoretical Model and Simulation  

E-Print Network (OSTI)

As for a variable air volume (VAV) system, the air duct static pressure is a typical control variable maintained by modulating supply fan speed. The static pressure equals to the summation of the duct pressure loss downstream of the sensor to the terminal box and box inlet static pressure. Typically, the air duct static pressure is set as a constant set point based on the system design information and sensor location. However, under partial load conditions, the terminal box dampers have to be closed more since either required airflow is less than the design airflow which directly leads to much less pressure loss. Thus the static pressure set point should be reset lower in order to reduce fan power, avoid noise at terminal box dampers and box damper malfunction due to excessive pressure. Different static pressure reset schedules are reviewed and compared, considering the influence of outside air temperature on the building load, availability of the VAV box damper positions, the airflow ratio based static pressure reset has also applicable advantages over the existing constant static pressure set point and two typical reset methods. This paper present the theoretical models to express the impacts of static pressure reset on fan airflow, fan head, air leakage, fan power and thermal energy for both pressure independent and pressure dependent boxes. The impacts are also demonstrated using the parametric analysis and numerical results to show the benefits of the static pressure reset including reducing fan power, cooling energy and heating energy.

Liu, M.; Feng, J.; Wang, Z.; Wu, L.; Zheng, K.; Pang, W.

2007-01-01T23:59:59.000Z

47

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners Title Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners Publication Type Report LBNL Report Number LBNL-63204 Year of Publication 2007 Authors McNeil, Michael A., and Maithili Iyer Date Published 03/2007 Keywords India Air Conditioner Efficiency Standards Abstract The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency.

48

Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration  

E-Print Network (OSTI)

operation at low fan speeds (LBL design) and operation --continuously design in the heat exchangers exhaust fans onDesign The basic objective of this project, to study the effects of exhaust fan

Grimsrud, David T.

2009-01-01T23:59:59.000Z

49

Laser sheet light flow visualization for evaluating room air flowsfrom Registers  

SciTech Connect

Forced air heating and cooling systems and whole house ventilation systems deliver air to individual rooms in a house via supply registers located on walls ceilings or floors; and occasionally less straightforward locations like toe-kicks below cabinets. Ideally, the air velocity out of the registers combined with the turbulence of the flow, vectoring of air by register vanes and geometry of register placement combine to mix the supply air within the room. A particular issue that has been raised recently is the performance of multiple capacity and air flow HVAC systems. These systems vary the air flow rate through the distribution system depending on the system load, or if operating in a ventilation rather than a space conditioning mode. These systems have been developed to maximize equipment efficiency, however, the high efficiency ratings do not include any room mixing effects. At lower air flow rates, there is the possibility that room air will be poorly mixed, leading to thermal stratification and reduced comfort for occupants. This can lead to increased energy use as the occupants adjust the thermostat settings to compensate and parts of the conditioned space have higher envelope temperature differences than for the well mixed case. In addition, lack of comfort can be a barrier to market acceptance of these higher efficiency systems To investigate the effect on room mixing of reduced air flow rates requires the measurement of mixing of supply air with room air throughout the space to be conditioned. This is a particularly difficult exercise if we want to determine the transient performance of the space conditioning system. Full scale experiments can be done in special test chambers, but the spatial resolution required to fully examine the mixing problem is usually limited by the sheer number of thermal sensors required. Current full-scale laboratory testing is therefore severely limited in its resolution. As an alternative, we used a water-filled scale model of a room in which whole-field supply air mixing maps of two vertical planes were measured using a Planar Laser-Induced Fluorescence (PLIF) measurement technique. Water marked with fluorescent dye was used to simulate the supply airflow; and the resulting concentrations within the water filled model show how the supply air mixes with the room air and are an analog for temperature (for thermal loads) or fresh air (for ventilation). In addition to performing experiments over a range of flow rates, we also changed register locations and examined the effects for both heating and cooling operation by changing the water density (simulating air density changes due to temperature changes) using dissolved salt.

Walker, Iain S.; Claret, Valerie; Smith, Brian

2006-04-01T23:59:59.000Z

50

The Influence of Operating Modes, Room Temperature Set Point and Curtain Styles on Energy Consumption of Room Air Conditioner  

E-Print Network (OSTI)

A field investigation was carried out in an office building of Changsha city in winter and summer, the influence of different running modes, curtain styles and room temperature set point on energy consumption of room air conditioner (RAC) was studied. The results show that: In summer automatic speed mode consumes the least refrigerating energy in different running modes, compared with low speed and high speed modes, it can conserve energy for 27.3% and 15.8%, respectively. In the same running mode, setting outer curtain can conserve energy for 40.9% and 20.4% compared with no curtain and inner curtain states, respectively. In winter high speed mode is the most efficient for saving energy which can decrease 40.3% and 30.9% compared with low speed and automatic speed modes. In the same running mode, setting inner curtain state makes the least heating energy consumption in cloudy day, about 10.8% and 2.7% less than no curtain and outer curtain states. However, it is not obvious when the day is fine. The heating energy consumption decreases as room temperature set point falls, compared with the energy consumption at 20.5 C and 19.5 C, it is decreases for 34.1% and17.0 % at 18.5 C, respectively. All the results will be the reference of environment design and control for air conditioning room.

Yu, J.; Yang, C.; Guo, R.; Wu, D.; Chen, H.

2006-01-01T23:59:59.000Z

51

DOE-HDBK-1169-2003; DOE Handbook Nuclear Air Cleaning Handbook  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

area and incorporating, as a minimum, a HEPA filter and a fan. Nuclear Air Cleaning Handbook U.S. Department of Energy G-2 Clean Room-An occupied room designed to maintain a...

52

Numerical method for computing nonlinear, time dependent, buoyant circulation of air in rooms  

Science Conference Proceedings (OSTI)

A method is described which solves the dynamic equations for air circulation at Grashof numbers that are in the range of environmental temperatures of rooms. Previous two-dimensional computation techniques were limited to G ? 105 ...

J. E. Fromm

1971-05-01T23:59:59.000Z

53

How Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? How Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? September 23, 2010 - 7:30am Addthis On Monday, Chris told you about his new ceiling fan and how it's changed the way he cools his home. In warm weather, ceiling fans cool people (not rooms) by producing a wind-chill effect-which is why you should turn off fans when you leave the room. A ceiling fan allows you to raise the thermostat setting about 4°F with no reduction in comfort. Ceiling fans don't just cool in the summer; you can also reverse the direction in the winter to provide an updraft and force warm air down into the room. How has a ceiling fan affected the way you heat and cool your home? Each Thursday, you have the chance to share your thoughts on a question

54

How Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? How Has a Ceiling Fan Affected the Way You Heat and Cool Your Home? September 23, 2010 - 7:30am Addthis On Monday, Chris told you about his new ceiling fan and how it's changed the way he cools his home. In warm weather, ceiling fans cool people (not rooms) by producing a wind-chill effect-which is why you should turn off fans when you leave the room. A ceiling fan allows you to raise the thermostat setting about 4°F with no reduction in comfort. Ceiling fans don't just cool in the summer; you can also reverse the direction in the winter to provide an updraft and force warm air down into the room. How has a ceiling fan affected the way you heat and cool your home? Each Thursday, you have the chance to share your thoughts on a question

55

Effect of room air recirculation delay on the decay rate of tracer gas  

NLE Websites -- All DOE Office Websites (Extended Search)

Effect of room air recirculation delay on the decay rate of tracer gas Effect of room air recirculation delay on the decay rate of tracer gas concentration Title Effect of room air recirculation delay on the decay rate of tracer gas concentration Publication Type Journal Article Year of Publication 2007 Authors Lorenzetti, David M., Astrid H. Kristoffersen, and Ashok J. Gadgil Journal Indoor Air Pagination 7 Keywords recirculating ventilation, tracer decay rate Abstract Tracer gas measurements are used to estimate the flow rate of fresh air into a room or building. These methods commonly account for the decay of tracer gas concentration as the result of ventilation air supply and infiltration, using a well-mixed model of the space. Some researchers also have considered the effect of leakage in the ventilation ductwork. This paper considers the effect of recirculation through ventilation ducts on the calculated fresh air supply rate. Transport delay in the ducts can significantly alter the time evolution of tracer concentration, and hence alter the estimated air change rate.

56

THE CONSTRUCTION AND OPERATION OF EXPERIMENTAL ROOMS FOR THE STUDY OF AIR-BORNE INFECTION*  

E-Print Network (OSTI)

In order to carry out adequately controlled studies on the effects of temperature and humidity on the behavior of bacteria and viruses suspended in the air under various experimental conditions, it became necessary to have available enclosed spaces in which any desired atmospheric state could be produced and maintained. The use of conventional methods of air conditioning is unsuitable for this purpose because all of these depend upon exchange of the air inside the experimental space with conditioned air. Hence, two identical air-tight, glass-walled rooms 8 feet X 10 feet and 8 feet high were built each within a separate air-conditioned shell which can be kept constantly at any temperature and relative humidity likely to be encountered in spaces occupied by human beings. Rapid circulation of the conditioned air over all surfaces of the inner room provides a sufficiently high rate of heat transfer to insure constant temperature conditions within that space. The relative humidity of the inner room can be maintained at the same level as the air of the outer shell or can be increased by the introduction of steam. Two rooms provide much greater

O. H. Robertson; Theodore T. Puck, Ph.D.; Henry Wise

1946-01-01T23:59:59.000Z

57

Parametric System Curves: Correlations Between Fan Pressure Rise and Flow for Large Commercial Buildings  

E-Print Network (OSTI)

Filter Pressure Loss Model for Fan Energy Calculation in Air2010. Selecting Efficient Fans. ASHRAE Journal, Vol. 52,Equipment: Chapter 20 Fans. Atlanta, GA: American Society

Sherman, Max

2010-01-01T23:59:59.000Z

58

Impacts of Static Pressure Reset on VAV System Air Leakage, Fan Power and Thermal Energy - Part 2: Case Demonstration for a Typical Climate System  

E-Print Network (OSTI)

In Part 1 of this paper, the theoretical models, integrating the fan airflow, fan head, air leakage factors, are developed to analyze the impacts of the static pressure reset on both pressure dependent and pressure independent terminal boxes. In this part, a simulated air handling unit (AHU) system in Omaha NE is used to demonstrate the energy savings performance in one typical climate year. This AHU system has a static pressure reset system and two constant static pressure systems, one having pressure dependent terminal boxes and one having pressure independent terminal boxes. These simulated systems were compared mainly on the basis of fan power energy consumption and thermal energy consumption in totally a year. The example presents a good agreement with the theoretical model and simulation results. It was also shown that static pressure reset provides a promising and challenging way for the energy performance in VAV system.

Liu, M.; Zheng, K.; Wu, L.; Wang, Z.; Johnson, C.

2007-01-01T23:59:59.000Z

59

Analysis of Energy Saving in a Clean Room Air-conditioning System  

E-Print Network (OSTI)

To address the issue of the substantial energy cost and operating cost of an all-return air system for a clean room, we changed the former system to a 2nd return air system. With the newest building energy simulation program, Energy Plus, we simulated and compared the summer energy consuming conditions of the two systems. Results prove the superiority of the 2nd return air system, and the validity of the simulation. Also, the air system energy performance in summer was illustrated with typical meteorological hour-to-hour data.

Liu, S.; Liu, J.; Pei, J.; Wang, M.

2006-01-01T23:59:59.000Z

60

Rui Fan  

NLE Websites -- All DOE Office Websites (Extended Search)

Rui Fan Rui Fan 1 Cyclotron Road MS 90-4000 Berkeley CA 94720 Office Location: 90-2087 (510) 486-6305 RFan@lbl.gov Vision & Mission Organization Awards Fellowship Staff Services...

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Save Energy with Axial Fans  

E-Print Network (OSTI)

There are several ways to save energy in wet cooling towers and air cooled heat exchangers using axial fans. This paper will discuss ways to improve fan system efficiency in wet and dry towers both during the design phase and after installation by specifying energy efficient equipment. Variable pitch fan versus fixed pitch fan operation is discussed in terms of energy savings and means of control. The areas of interest to wet cooling tower users would be the influence on fan diameter and operating point on horsepower, how and when are velocity recovery stacks effective, the effect of varying fan speed to improve efficiency, and tip clearance effects. The areas of interest to dry tower (air cooled heat exchanger) users would be the effect of inlet losses, approach velocity losses, and losses due to air recirculation.

Monroe, R. C.

1981-01-01T23:59:59.000Z

62

Ceiling Fan and Ceiling Fan Light Kit use in the U.S. Results of a Survey on Amazon Mechanical Turk  

E-Print Network (OSTI)

air conditioning .31 3.7 Impact of ceiling fans on air conditioningowners increased the air conditioning thermostat temperature

Kantner, Colleen L.S.

2013-01-01T23:59:59.000Z

63

Room Temperature Control During Season Switchover with Single Duct Variable Air Volume System Without Reheat  

E-Print Network (OSTI)

The Langford A building houses the College of Architecture on TAMU campus. There are ten singleduct variable air volume (VAV) air-handling units (AHUs) without reheat serving the building. The local pneumatic thermostats modulate the dampers of VAV boxes to maintain room temperature at their setpoints. The thermostat action is switched from direct acting (DA) to reverse acting (RA) when the season changes from fall to winter and vice versa from winter to spring, based on the out side air temperature, when season changes. This results in various parts of the building ether too cold or too hot during the season change. This paper presents that the thermostat action will be switched according to cooling loads or discharge air temperature, instead of outside air temperature. For the interior zone, thermostat action does not need to be switched at all. The comfort is improved and savings is achieved by the new control scheme. Because some air-handling units (AHUs) serve both interior and exterior zones, this system never worked as intended. The system must be modified to have zone reheat and the AHUs discharge air temperature is set below dew point for humidity control.

Liu, C.; Deng, S.; Claridge, D. E.; Turner, W. D.; Bruner, H.

2003-01-01T23:59:59.000Z

64

THE WORLD'S Biggest Fan Collection  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

WORLD'S Biggest Fan Collection WORLD'S Biggest Fan Collection If you only know the Big Ass Fan Company as the preeminent designer and manufacturer of high volume, low speed fans for factories and cows, it's time you get to know us better. While we continue to lead the way in industrial and agricultural air movement, we've also refined these designs to bring the same innovation and benefits of our famous fans to circulate an ocean of air in sound-sensitive commercial spaces and homes. And when our customers said they wanted something for smaller spaces, we listened - and we think you'll like the results. We've got you covered - ceiling to floor, wall to door! Features  New patented airfoil system uses 10 Powerfoil airfoils, winglets and patent-pending AirFence(tm) technology to increase

65

MULTI - TRACER CONTROL ROOM AIR INLEAKAGE PROTOCOL AND SIMULATED PRIMARY AND EXTENDED MULTI - ZONE RESULTS.  

SciTech Connect

The perfluorocarbon tracer (PFT) technology can be applied simultaneously to the wide range in zonal flowrates (from tens of cfms in some Control Rooms to almost 1,000,000 cfm in Turbine Buildings), to achieve the necessary uniform tagging for subsequent determination of the desired air inleakage and outleakage from all zones surrounding a plant's Control Room (CR). New types of PFT sources (Mega sources) were devised and tested to handle the unusually large flowrates in a number of HVAC zones in power stations. A review of the plans of a particular nuclear power plant and subsequent simulations of the tagging and sampling results confirm that the technology can provide the necessary concentration measurement data to allow the important ventilation pathways involving the Control Room and its air flow communications with all adjacent zones to be quantitatively determined with minimal uncertainty. Depending on need, a simple single or 3-zone scheme (involving the Control Room alone or along with the Aux. Bldg. and Turbine Bldg.) or a more complex test involving up to 7 zones simultaneously can be accommodated with the current revisions to the technology; to test all the possible flow pathways, several different combinations of up to 7 zones would need to be run. The potential exists that for an appropriate investment, in about 2 years, it would be possible to completely evaluate an entire power plant in a single extended multizone test with up to 12 to 13 separate HVAC zones. With multiple samplers in the Control Room near each of the contiguous zones, not only will the prevalent inleakage or outleakage zones be documented, but the particular location of the pathway's room of ingress can be identified. The suggested protocol is to perform a 3-zone test involving the Control Room, Aux. Bldg., and Turbine Bldg. to (1) verify CR total inleakage and (2) proportion that inleakage to distinguish that from the other 2 major buildings and any remaining untagged locations. These results would then direct the next subsequent tests. Final results would point to where mitigation steps should be initiated. Protocols for repeat testing as well as long term continual testing are suggested.

DIETZ,R.N.

2002-01-01T23:59:59.000Z

66

MECHANICAL DRAFT FANS FOR THE MODERN INCINERATOR  

E-Print Network (OSTI)

design and modiftcation. Spe cial blading and fan construction for use under corrosive conditions this will be kept fairly constant by air or water cooling during noral op eration. Since the fan will be designed. Volume control on a single inlet fan can be accomplished with a variable inlet #12;vane, designed

Columbia University

67

Commissioning Tools for Heating/Cooling System in Residence - Verification of Floor Heating System and Room Air Conditioning System Performance  

E-Print Network (OSTI)

Tools of evaluating the performance of floor heating and room air conditioner are examined as a commissioning tool. Simple method is needed to check these performance while in use by residents, because evaluation currently requires significant time and effort. Therefore, this paper proposes a) two methods of evaluating the floor heating efficiency from the room / crawl space temperature and the energy consumption and b) method of evaluating COP of the room air conditioner from the data measured at the external unit. Case studies in which these tools were applied to actual residences are presented to demonstrate their effectiveness.

Miura, H.; Hokoi, S.; Iwamae, A.; Umeno, T.; Kondo, S.

2004-01-01T23:59:59.000Z

68

Fan Dai  

NLE Websites -- All DOE Office Websites (Extended Search)

Fan Dai Fan Dai China Energy Group Lawrence Berkeley National Laboratory 1 Cyclotron Road MS 90R2002 Berkeley CA 94720 Office Location: 90-2117S (510) 486-4000 FDai@lbl.gov Fan Dai is a Ph.D. Candidate in Environmental Policy at the College of Environmental Science and Forestry, State University of New York, and a LL.M. Candidate at Berkeley School of Law, University of California. Fan's research during her stay in LBNL's China Energy Group focuses on Energy Efficiency Governance, U.S.-China Clean Energy Partnership, the Carbon Cap-and-Trade Program in California and what China can learn from California's program. Prior to LBNL, she interned at the China National Center for Climate Change Strategy and International Cooperation (NCSC), China Youth Action Climate Network (CYCAN), and China State Forestry

69

FANS - Control  

Science Conference Proceedings (OSTI)

... If set to H+ and a magnet controller is connected, you are ... Typically motors 3, 4, 5, and 6 are fixed for FANS operation A fixed motor will not be ...

70

ZHAOSHENG FAN  

NLE Websites -- All DOE Office Websites (Extended Search)

ZHAOSHENG FAN Biosciences Division, Argonne National Laboratory, Argonne, IL 60439 Phone: (630) 252-1566; email: zfan@anl.gov EDUCATION Ph.D., Soil Physics, 2007, North Dakota...

71

Museum Fan Downloads  

NLE Websites -- All DOE Office Websites (Extended Search)

Museum Fan Downloads Participate with us Participate Share your Stories Museum Fan Downloads invisible utility element Museum Fan Downloads Help the Bradbury Science Museum by...

72

The effect of fan and heat sink design on heat removal from microprocessor chips.  

E-Print Network (OSTI)

??Air flow and heat removal characteristics for fan/heat sink designs used to cool Pentium class processors were analyzed. Five designs were tested for fan speed, (more)

Baltrip, Kedra G

2012-01-01T23:59:59.000Z

73

Cooling with a Whole House Fan | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Cooling with a Whole House Fan Cooling with a Whole House Fan Cooling with a Whole House Fan May 30, 2012 - 6:54pm Addthis Whole house fan installed as part of a home retrofit project in California. | Photo courtesy of Lieko Earle, NREL. Whole house fan installed as part of a home retrofit project in California. | Photo courtesy of Lieko Earle, NREL. What does this mean for me? A whole-house fan may be sufficient to cool your house, at least for part of the year. In many climates, a whole-house fan can save you money and maintain comfort during the cooling season. How does it work? A whole-house fan works by pulling air in through windows and exhausting it through the attic and roof. Whole house cooling using a whole house fan can substitute for an air conditioner most of the year in most climates. Whole house fans combined

74

Development of In-Situ Fan Curve Measurement with One Airflow Measurement  

E-Print Network (OSTI)

Fan airflow is the key parameter for air volume tracking control in variable air volume systems. One of the airflow measurement methods is to determine airflow using the fan speed, fan head, and fan curve. Both fan speed and fan head can be measured accurately. Therefore, the accuracy of the fan airflow depends on the accuracy of the fan curve. An experimental method has been developed to determine the in-situ fan curve with only one airflow measurement. This paper presents the theoretical background, experimental procedures, and verification results.

Liu, G.; Joo, I. S.; Song, L.; Liu, M.

2003-01-01T23:59:59.000Z

75

Airflow Simulation and Energy Analysis in Ventilated Room with a New Type of Air Conditioning  

E-Print Network (OSTI)

Airflow simulation in one ventilated room with radiant heating and natural ventilation has been carried out. Three cases are compared: the closed room, the room with full openings, and the room with small openings. The radiator heating room with small openings is recommended. The airflow and thermal comfort are discussed for the last case. It is suitable for two kinds of civil buildings, housing buildings and office buildings, which take up the largest part of all functional buildings.

Liu, D.; Tang, G.; Zhao, F.

2006-01-01T23:59:59.000Z

76

An Innovative Method for Dynamic Characterization of Fan Filter Unit Operation.  

E-Print Network (OSTI)

that is affected by fan-wheel design, air-path and size,by- 4-ft) fan filter units with various design, operation,differential the design and control schemes of fan filter

Xu, Tengfang

2006-01-01T23:59:59.000Z

77

Toward green systems for cleanrooms: Energy efficient fan-filter units  

E-Print Network (OSTI)

M. and F. Tsau. 2002. Fan-Filter Unit (FFU) Test Procedures.Laboratory Methods of Testing Fans for Rating, Air MovementTest Procedure For Fan-Filter Units (not published). [6] Xu,

Jeng, Ming-Shan; Xu, Tengfang; Lan, Chao-Ho

2004-01-01T23:59:59.000Z

78

Laboratory evaluation of fan/filter units' aerodynamic and energy performance  

E-Print Network (OSTI)

Jeng, M.S. , F. Tsau. 2002. Fan-Filter Unit (FFU) TestLaboratory Methods of Testing Fans for Rating, Air MovementTest Procedure For Fan-Filter Units (not published). Xu,

Xu, Tengfang; Jeng, Ming-Shan

2004-01-01T23:59:59.000Z

79

Effect of building airtightness and fan size on the performance of mechanical ventilation systems in new U.S. houses: a critique of ASHRAE standard 62.2-2003  

E-Print Network (OSTI)

Determining Air Leakage Rate by Fan Pressurization. Americanof Building Envelopes by the Fan Pressurization Method.Dominated by Strong Exhaust Fan. ASHRAE Transactions. Vol

Roberson, J.

2004-01-01T23:59:59.000Z

80

Techno-Economic Analysis of Indian Draft Standard Levels for RoomAir Conditioners  

SciTech Connect

The Indian Bureau of Energy Efficiency (BEE) finalized its first set of efficiency standards and labels for room air conditioners in July of 2006. These regulations followed soon after the publication of levels for frost-free refrigerators in the same year. As in the case of refrigerators, the air conditioner program introduces Minimum Efficiency Performance Standards (MEPS) and comparative labels simultaneously, with levels for one to five stars. Also like the refrigerator program, BEE defined several successive program phases of increasing stringency. In support of BEE's refrigerator program, Lawrence Berkeley National Laboratory (LBNL) produced an analysis of national impacts of standards in collaboration with the Collaborative Labeling and Standards Program (CLASP). That analysis drew on LBNL's experience with standards programs in the United States, as well as many other countries. Subsequently, as part of the process for setting optimal levels for air conditioner regulations, CLASP commissioned LBNL to provide support to BEE in the form of a techno-economic evaluation of air conditioner efficiency technologies. This report describes the methodology and results of this techno-economic evaluation. The analysis consists of three components: (1) Cost effectiveness to consumers of efficiency technologies relative to current baseline. (2) Impacts on the current market from efficiency regulations. (3) National energy and financial impacts. The analysis relied on detailed and up-to-date technical data made available by BEE and industry representatives. Technical parameters were used in conjunction with knowledge about air conditioner use patterns in the residential and commercial sectors, and prevailing marginal electricity prices, in order to give an estimate of per-unit financial impacts. In addition, the overall impact of the program was evaluated by combining unit savings with market forecasts in order to yield national impacts. LBNL presented preliminary results of these analyses in May 2006, at a meeting of BEEs Technical Committee for Air Conditioners. This meeting was attended by a wide array of stakeholder, including industry representatives, engineers and consumer advocates. Comments made by stakeholders at this meeting are incorporated into the final analysis presented in this report. The current analysis begins with the Rating Plan drafted by BEE in 2006, along with an evaluation of the market baseline according to test data submitted by manufacturers. MEPS, label rating levels, and baseline efficiencies are presented in Section 2. First, we compare Indian MEPS with current standards in other countries, and assess their relative stringency. Baseline efficiencies are then used to estimate the fraction of models likely to remain on the market at each phase of the program, and the impact on market-weighted efficiency levels. Section 3 deals with cost-effectiveness of higher efficiency design options. The cost-benefit analysis is grounded in technical parameters provided by industry representatives in India. This data allows for an assessment of financial costs and benefits to consumers as a result of the standards and labeling program. A Life-Cycle Cost (LCC) calculation is used to evaluate the impacts of the program at the unit level, thus providing some insight into the appropriateness of the levels chosen, and additional opportunities for further ratcheting. In addition to LCC, we also calculate payback periods, cost of conserved energy (CCE), and return on investment (ROI). Finally, Section 4 covers national impacts. This is an extension of unit level estimates in the two previous sections. Extrapolation to the national level depends on a forecast of air conditioner purchases (shipments), which we describe here. Following the cost-benefit analysis, we construct several efficiency scenarios including the BEE plan, but also considering further potential for efficiency improvement. These are combined with shipments through a stock accounting model in order to forecast air conditioner energy consumption

McNeil, Michael A.; Iyer, Maithili

2007-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

will result in rising sales prices. VRF Air Conditioner Themain users of VRF air conditioners are commercial usersand large-scale households, and VRF air conditioners usually

Zhou, Nan

2010-01-01T23:59:59.000Z

82

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

Refrigeration and Air Conditioning Industry Association Junein the context of the air conditioning industry, the profileand improvement of the air conditioning industry and the

Zhou, Nan

2010-01-01T23:59:59.000Z

83

List of Ceiling Fan Incentives | Open Energy Information  

Open Energy Info (EERE)

Fan Incentives Fan Incentives Jump to: navigation, search The following contains the list of 99 Ceiling Fan Incentives. CSV (rows 1 - 99) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio (Electric) - Residential Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Residential Building Insulation Ceiling Fan Central Air conditioners Custom/Others pending approval Duct/Air sealing Heat pumps Lighting Motors Programmable Thermostats Windows Yes AEP Ohio (Gas) - Residential Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Residential Building Insulation Ceiling Fan Central Air conditioners Custom/Others pending approval Dehumidifiers Duct/Air sealing Heat pumps Lighting Motors Programmable Thermostats

84

How the Number and Placement of Sensors Controlling Room Air Distribution Systems Affect Energy Use and Comfort  

E-Print Network (OSTI)

This study assesses the impact of sensor number and placement on the energy needed to condition a typical office using several likely variants of an underfloor air distribution system (UFAD). The study uses an empirical-based room stratification model developed from full-scale tests of UFAD systems. Annual energy consumption is calculated for an interior zone using outside air temperature bin data. The comfort criteria are taken from ASHRAE standard 55-92. The simulations indicate that there are benefits derived from using more than one temperature sensor to control conditions in the occupied zone of a room. Among these are: 1. By adjusting both supply air temperature and volume to maintain the maximum allowable thermal gradient in the occupied (lower) part of the room, an optimal supply air condition can reduce energy use (relative to the best arrangement of a single sensor) while maintaining comfort; 2. Discomfort caused by stratification can be detected by having one of the sensors located at foot level; 3. For the simulated UFAD interior zone of a typical office building in Sacramento, an overall energy saving of 8%/24% (VAV/CAV respectively) can be achieved when two sensors as opposed to one are used to control room conditions.

Wang, D.; Arens, E.; Webster, T.; Shi, M.

2002-01-01T23:59:59.000Z

85

Fuzzy expert system design for operating room air-condition control systems  

Science Conference Proceedings (OSTI)

In this study, a controlled fuzzy expert system (FES) was designed to provide the conditions necessary for operating rooms. For this purpose, existing operating rooms have been studied to see if there are more useful, reliable and comfortable ones. How ... Keywords: Adaptive fuzzy control, Expert systems, Fuzzy control systems, Operating room control

Nazmi Etik; Novruz Allahverdi; Ibrahim Unal Sert; Ismail Saritas

2009-08-01T23:59:59.000Z

86

An Initial Study on Applying Active Noise Control to an Insulated Box Fan Used in Ventilation System Applications.  

E-Print Network (OSTI)

??In many different applications and buildings fans are used to remove unwanted and used air. These fans often generate broadband and tonal noise. Commonly, passive (more)

Larsson, Martin; Johansson, Sven; Muddala, S.M.; Gafar, A.E.; Hkansson, Lars; Tarkka, Juhani

2009-01-01T23:59:59.000Z

87

Fan Mei | BNL  

NLE Websites -- All DOE Office Websites (Extended Search)

Fan Mei Postdoctoral Research Associate Fan is currently working as a postdoctoral research associate with Jian Wang, investigating aerosol microphysical properties in three recent...

88

High Efficiency Fans and High Efficiency Electrical Motors  

E-Print Network (OSTI)

Replacing nominal efficient electrical motors with premium efficiency can save on electrical power costs in cotton gins. Connected horsepower load on industrial air fans is approximately 60% of the total horsepower in a typical cotton gin. By replacing old inefficient centrifugal fans with new higher efficiency fans, additional power savings can be achieved.

Breedlove, C. W.

1989-09-01T23:59:59.000Z

89

Upgrading of the Air-conditioning of the Computer Room in the Computer Centre for the LHC era  

E-Print Network (OSTI)

Built in the beginning of 1970's, the Computer Centre air-conditioning and cooling systems were designed to be modular and easily adaptable to the unpredictable future needs of computing. The infrastructure of LHC-computing that will be housed in the existing Computer Room with its five Computing farms and over 11000 PC's increases the requirements of cooling and air-conditioning power to a new level. The nominal thermal loads from the equipment rise from the current design maximum of 1MW to estimated maximum of 2MW in the future. This paper presents calculations and proposes solutions to meet the new nominal requirements. The air-conditioning system must also be able to cope with a situation of power cut in the main supply. A calculation of the temperature evolution during the power cut and a justified operation strategy for this scenario is also presented.

Lindroos, J

2001-01-01T23:59:59.000Z

90

The Lillehammer Submarine Fan Complex.  

E-Print Network (OSTI)

??Abstract The Lillehammer Submarine Fan Complex is a mixed mud/sand rich turbidite fan system. The fan complex was deposited in the Neoproterozoic Hedmark rift basin (more)

Skaten, Maren Kristin Mllerup

2006-01-01T23:59:59.000Z

91

Ceiling Fan | Open Energy Information  

Open Energy Info (EERE)

Ceiling Fan Jump to: navigation, search TODO: Add description List of Ceiling Fan Incentives Retrieved from "http:en.openei.orgwindex.php?titleCeilingFan&oldid267151"...

92

Enabling Energy-Efficient Approaches to Thermal Comfort Using Room Air Motion  

E-Print Network (OSTI)

uc/item/4488d1b8 Energy Efficiency, Thermal Comfort with Airuc/item/4488d1b8 Energy Efficiency, Thermal Comfort with Airuc/item/4488d1b8 Energy Efficiency, Thermal Comfort with Air

Pasut, Wilmer; Arens, Edward; Zhang, Hui; Kaam, Soazig; Zhai, Yongchao

2013-01-01T23:59:59.000Z

93

Nien-fan Zhang  

Science Conference Proceedings (OSTI)

Nien-fan Zhang. Technical Areas of Research and Consulting: Statistical process control Time series analysis and forecasting. Awards: ...

2012-07-16T23:59:59.000Z

94

Investigation of air supply conditions in the room of a B11type gas appliance  

Science Conference Proceedings (OSTI)

In Hungary, the prevalently used "B11" type gas appliances equipped with atmospheric burner and they have a draught hood beyond the outlet of the appliance. For the appropriate adjustment of the gas boiler to the conditions of the building, ... Keywords: CFD method, air supply, chimney, design requirements, gas appliances, numerical modelling

Lajos Barna; Rbert Goda

2007-05-01T23:59:59.000Z

95

Fan Energy Savings Decisions  

E-Print Network (OSTI)

Axial fans are used for thousands of industrial applications consuming millions of kilowatts daily. The decision that saves dollars is to either automatically change fan speed or change blade pitch to save up to 50 percent of consumed power over a fixed pitch, constant speed fan. A discussion of the merits of each type is presented with actual test results.

Monroe, R. C.

1985-05-01T23:59:59.000Z

96

Research on the Integration Characteristics of Cooling Energy Recovery from Room Exhausting Cool Air in Summer  

E-Print Network (OSTI)

Currently, the design and construction of buildings and building energy systems are far from reasonable. The requirement and consumption of primary energy resources is aggravated, the use of building energy is free and wasteful, and pollution of the earth's atmosphere from building energy consumption is also aggravated. Therefore, the research and applications of energy efficiency and environmentally benign building energy systems are very important and urgent. Until now, much work on building energy conservation methods, measures and evaluations have been done by people in many countries. Some theoretical achievements have been already put into practice, but most of them put undue emphasis on some parts of the whole system. The complete idea of building energy conservation by integrating the building energy systems has not been put forward, and unequivocal guidance and a complete evaluation index and theoretical system for building energy consumption and its impact on the environment have not been formed. In this paper, we make further suggestions for improvement, and present some new concepts such as building energy flow, building mass flow, couple recovering of building discharge energy, integrated system of building energy , factor of building energy integration I, and effect factor on atmospheric environment of building energy F. The positive effects of these new concepts and methods on traditional approaches are also predicted. Theoretical research on an energy recovery unit that recovers cooling energy from indoor exhausting cool air in summer has been done in this paper, and demonstrates great advantages of its integration characteristics of building thermal systems.

Zhang, W.; Wu, J.; Wei, Y.

2006-01-01T23:59:59.000Z

97

Record of Communication Concerning Ceiling Fan and Ceiling Fan...  

NLE Websites -- All DOE Office Websites (Extended Search)

Record of Communication Concerning Ceiling Fan and Ceiling Fan Light Kit Framework Document-Docket No. EERE-2012-BT-STD-0045 Record of Communication Concerning Ceiling Fan and...

98

Microsoft Word - Control_and_Fan_Improvements_in_CRAHs.doc  

NLE Websites -- All DOE Office Websites (Extended Search)

07E 07E Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers Henry Coles and Steve Greenberg, Lawrence Berkeley National Laboratory Corinne Vita, Vigilent Environmental Energy Technologies Division November 2012 DISCLAIMER This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe

99

Fan-speed-aware scheduling of data intensive jobs  

Science Conference Proceedings (OSTI)

As server processor power densities increase, the cost of air cooling also grows resulting from higher fan speeds. Our measurements show that vibrations induced by fans in high-end servers and its rack neighbors cause a dramatic drop in hard disk bandwidth, ... Keywords: cooling, disk i/o, energy, thermal, vibration

Christine S. Chan; Yanqin Jin; Yen-Kuan Wu; Kenny Gross; Kalyan Vaidyanathan; Tajana `imuni Rosing

2012-07-01T23:59:59.000Z

100

Design and Specification Guidelines for Large Draft Fans and Systems  

Science Conference Proceedings (OSTI)

Design shortcomings in draft fans and related air-gas systems can cause fan failure and costly outages of large fossil fuel power plants. These guidelines will help engineers and manufacturers achieve a better understanding of the design features needed to minimize such failures.

1983-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Condition Monitoring of Fans With Rolling Element Bearings  

Science Conference Proceedings (OSTI)

Data on high-frequency vibration caused by the impacts of bearing pits and spalls can help utilities schedule equipment maintenance. One data collection technique, developed through long-term monitoring of combustion air axial fans at the Pennsylvania Electric Company Homer City station, helps plant personnel anticipate failures of draft fan antifriction bearings by several months.

1988-03-22T23:59:59.000Z

102

Interaction of Plutonium with Diverse Materials in Moist Air and Nitrogen-Argon Atmospheres at Room Temperature  

DOE Green Energy (OSTI)

Chemical and radiolytic interactions of weapons-grade plutonium with metallic, inorganic, and hydrogenous materials in atmospheres containing moist air-argon mixtures have been characterized at room temperature from pressure-volume-temperature and mass spectrometric measurements of the gas phase. A reaction sequence controlled by kinetics and gas-phase composition is defined by correlating observed and known reaction rates. In all cases, O{sub 2} is eliminated first by the water-catalyzed Pu + O{sub 2} reaction and H{sub 2}O is then consumed by the Pu + H{sub 2}O reaction, producing a gas mixture of N{sub 2}, argon, and H{sub 2}. Hydrogen formed by the reaction of water and concurrent radiolysis of hydrogenous materials either reacts to form PuH{sub 2} or accumulates in the system. Accumulation of H{sub 2} is correlated with the presence of hydrogenous materials in liquid and volatile forms that are readily distributed over the plutonium surface. Areal rates of radiolytic H{sub 2} generation are determined and applied in showing that modest extents of H{sub 2} production are expected for hydrogenous solids if the contact area with plutonium is limited. The unpredictable nature of complex chemical systems is demonstrated by occurrence of the chloride-catalyzed Pu + H{sub 2}O reaction in some tests and hydride-catalyzed nitriding in another.

John M. Haschke; Raymond J. Martinez; Robert E. Pruner II; Barbara Martinez; Thomas H. Allen

2001-04-01T23:59:59.000Z

103

Acceptance test procedure MICON software exhaust fan control modifications  

Science Conference Proceedings (OSTI)

This acceptance test verifies the MICON program changes for the new automatic transfer switch ATS-2 alarms, the Closed Loop Cooling isolator status, the CB-3 position alarm, and the alarms for the new emergency fan damper backup air compressor.

SILVAN, G.R.

1999-05-21T23:59:59.000Z

104

Energy Efficient Single Stack Exhaust Fan Systems (E3S3F)  

E-Print Network (OSTI)

This paper first investigates the fan energy performance of a constant air volume exhaust system. Two single stack energy efficient exhaust fan systems (E3S3F) are presented. The E3S3F-I has the static pressure sensor located at the inlet of the exhaust fan. It has been found to consume up to 15% less fan power than conventional constant air volume exhaust systems. The E3S3F-II uses a variable speed device to maintain the static pressure at the entrance of the stack. It consumes up to 60% less fan power than conventional constant volume exhaust systems.

Wang, G.; Liu, M.

2001-01-01T23:59:59.000Z

105

FLIGHT CONTROL DESIGN OF TANDEM DUCTED FAN AIRCRAFT USING REDUNDANT CONTROL EFFECTORS.  

E-Print Network (OSTI)

??Controllability and stability of ducted fan air vehicles is a challenging problem due to their complex nonlinear aerodynamics and dynamic behavior. At the same time, (more)

Ozdemir, Gurbuz

2010-01-01T23:59:59.000Z

106

Fan-less long range alpha detector  

DOE Patents (OSTI)

A fan-less long range alpha detector which operates by using an electrical field between a signal plane and the surface or substance to be monitored for air ions created by collisions with alpha radiation. Without a fan, the detector can operate without the possibility of spreading dust and potential contamination into the atmosphere. A guard plane between the signal plane and the electrically conductive enclosure and maintained at the same voltage as the signal plane, reduces leakage currents. The detector can easily monitor soil, or other solid or liquid surfaces.

MacArthur, Duncan W. (Los Alamos, NM); Bounds, John A. (Los Alamos, NM)

1994-01-01T23:59:59.000Z

107

Fan-less long range alpha detector  

DOE Patents (OSTI)

A fan-less long range alpha detector is disclosed which operates by using an electrical field between a signal plane and the surface or substance to be monitored for air ions created by collisions with alpha radiation. Without a fan, the detector can operate without the possibility of spreading dust and potential contamination into the atmosphere. A guard plane between the signal plane and the electrically conductive enclosure and maintained at the same voltage as the signal plane, reduces leakage currents. The detector can easily monitor soil, or other solid or liquid surfaces. 2 figures.

MacArthur, D.W.; Bounds, J.A.

1994-05-10T23:59:59.000Z

108

Fan Repair Guideline  

Science Conference Proceedings (OSTI)

The successful repair of a fan component is affected by a number of different factors. These include correctly assessing the root cause of failure, determining the best repair option, implementation of proper repair procedures, and compliance with applicable codes and standards. However, in many situations the proper solution is not clearly evident. The purpose of this document is to provide guidance in the area of induced draft / forced draft fan repair. Specifically, this document deals with the repair...

2002-08-15T23:59:59.000Z

109

Evaluation of the cooling fan efficiency index.  

E-Print Network (OSTI)

Evaluation of the Cooling Fan Efficiency indexfor a desk fan anda computer fan Stefano Schiavon 1,2,* , M. Sc. PhD

Schiavon, Stefano; Melikov, Arsen

2009-01-01T23:59:59.000Z

110

Best Practice for Energy Efficient Cleanrooms: Fan-FilterUnits  

Science Conference Proceedings (OSTI)

The HVAC systems in cleanrooms may use 50 percent or more of the total cleanroom energy use. Fan energy use accounts for a significant portion (e.g., over 50%) of the HVAC energy use in cleanrooms such as ISO Classes 3, 4, or 5. Three types of air-handling systems for recirculating airflows are commonly used in cleanrooms: (1) fan-tower systems with pressurized plenum, (2) ducted HEPA systems with distributed-fans, and (3) systems with fan-filter units. Because energy efficiency of the recirculation systems could vary significantly from system type to system type, optimizing aerodynamic performance in air recirculation systems appears to be a useful approach to improve energy efficiency in cleanrooms. Providing optimal airflows through careful planning, design and operation, including air change rate, airflow uniformity, and airflow speed, is important for controlling particle contamination in cleanrooms. In practice, the use of fan-filter units (FFUs) in the air-handling system is becoming more and more popular because of this type of system may offer a number of advantages. Often modular and portable than traditional recirculation airflow systems, FFUs are easier to install, and can be easily controlled and monitored to maintain filtration performance. Energy efficiency of air handling systems using fan-filter units can, however, be lower than their counterparts and may vary significantly from system to system because of the difference in energy performance, airflow paths, and the operating conditions of FFUs.

Xu, Tengfang

2005-06-15T23:59:59.000Z

111

Avoiding 100 new power plants by increasing efficiency of room air conditioners in India: opportunities and challenges  

SciTech Connect

Electricity demand for room ACs is growing very rapidly in emerging economies such as India. We estimate the electricity demand from room ACs in 2030 in India considering factors such as weather and income growth using market data on penetration of ACs in different income classes and climatic regions. We discuss the status of the current standards, labels, and incentive programs to improve the efficiency of room ACs in these markets and assess the potential for further large improvements in efficiency and find that efficiency can be improved by over 40% cost effectively. The total potential energy savings from Room AC efficiency improvement in India using the best available technology will reach over 118 TWh in 2030; potential peak demand saving is found to be 60 GW by 2030. This is equivalent to avoiding 120 new coal fired power plants of 500 MW each. We discuss policy options to complement, expand and improve the ongoing programs to capture this large potential.

Phadke, Amol; Abhyankar, Nikit; Shah, Nihar; [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

2013-10-15T23:59:59.000Z

112

Introduction of a Cooling Fan Efficiency Index  

E-Print Network (OSTI)

with four cooling fans of different designs available on thedesign, installation, and use, the performance of cooling fans

Schiavon, Stefano; Melikov, Arsen

2009-01-01T23:59:59.000Z

113

Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre  

E-Print Network (OSTI)

Proposal for the award of a contract for the design, supply, installation and commissioning of a Heating, Ventilation and Air-Conditioning (HVAC) system for the computer room of the CERN Control Centre

2012-01-01T23:59:59.000Z

114

Performance Assessment of Photovoltaic Attic Ventilator Fans  

E-Print Network (OSTI)

Controlling summer attic heat gain is important to reducing air conditioning energy use in homes in hot-humid climates. Both heat transfer through ceilings and t attic duct systems can make up a large part of peak cooling demand, Attic ventilation has long been identified as a method to abate such heat gains. We present test results from using the photovoltaic (PV) attic ventilator fans in a test home to assess impact on attic and cooling energy performance.

Parker, D. S.; Sherwin, J. R.

2000-01-01T23:59:59.000Z

115

HVAC Fans and Dampers Maintenance Guide  

Science Conference Proceedings (OSTI)

Heating, ventilation, and air conditioning (HVAC) systems serve an important function in nuclear power plants because these systems are responsible for maintaining many environmental conditions throughout the facility. Failure of these components can induce undesirable radiological conditions and stressful working conditions, and can compromise the life of qualified equipment. Some HVAC fan and damper failures are preventable by monitoring operating parameters and performing recommended maintenance activ...

1999-08-26T23:59:59.000Z

116

Mass and fans in attached sunspaces  

DOE Green Energy (OSTI)

The effect of thermal storage mass on the performance of an attached sunspace is investigated for a particular design in Boston. Mass in the sunspace and in the adjoining building are compared. Performance is evaluated in terms of temperature conditions in the sunspace and delivery of useful solar heat to the adjoining building. The dependence of the results on the manner of heat delivery is studied. Both natural convection and fan-forced air flow are included.

Jones, R.W.; McFarland, R.D.; Lazarus, G.S.

1982-01-01T23:59:59.000Z

117

Fan System Effects: How Fan Ductwork Design Impacts Overall System Efficiency and What the Approach Should be for Optimization  

E-Print Network (OSTI)

"In order to establish the aerodynamic performance characteristics of a custom fan or even a line of fans, the accepted practice of the industry is to carry out testing on a scale model in a laboratory to develop its fan performance curve. Then by applying affinity laws in conjunction with very specific rules that address scaling issues, the performance characteristics of geometrically similar fans can be predicted. These affinity laws (frequently referred to as fan laws) also allow the performance of fans operating at different speeds or handling gases at different density values to be accurately predicted. However, it is often found that even fans with well defined and pedigreed performance curves are unable to meet their performance expectations once they are installed on the systems for which they have been sold. This is primarily due to the adverse aerodynamic impact of the inlet or outlet connections on the performance capacity of the fan and thus on the overall system efficiency. The general term for design conditions at inlets or outlets of fans that cause deficient aerodynamic performance is system effects. The characteristics of fan system effects are that they reduce fan capacity and are both velocity and geometry dependent. On the inlet side of a fan, this generally characterizes itself by a flow pattern that is highly non?uniform. On the discharge side, the high and low velocity flow streams leaving the fan may simply be prevented from redeveloping a uniform flow profile and normal static pressure conversion before encountering a disturbance. The term can also apply to system elements such as silencers, elbows and transitions. For these components, the actual pressure drop across them may be significantly higher than their calculated or rated values if the velocity profile of the entering flow is skewed or non?uniform. For either case (fan connection or system component), the result is that additional power will be required to address the flow rate required by the system. In many instances, system designers are simply unfamiliar with the importance of understanding system effects as it pertains to new fan selections and the attendant power requirements. At a minimum, a reasonable approach for new fan projects should be to establish the theoretical system effect of connection designs by using a recognized document such as Air Movement and Control Association Publication 201. The objective should be to first minimize their impact through appropriate connection design modifications in conjunction with potential fan inlet and outlet re?orientation. Once the system effects are minimized, the residual value should be applied to the fan performance specification in order to ensure that the fan is selected for the required aerodynamic capacity. For system components, an approach that has proved to be of significant value is to predict the flow pattern using computation fluid dynamics (CFD) modelling tools and in this process, the design can be tweaked until the designer finds the overall pressure drops of a system are minimized to the greatest practical extent. Similarly, CFD can be used to predict the flow profile at a fan inlet to ensure that it is as uniform as practically possible. This paper reviews the concept of system effects from the perspective of fan power requirements and provides a methodology for approaching system design from the perspective of optimizing fan energy use while achieving the required system capacity."

Martin, V.

2009-05-01T23:59:59.000Z

118

Induced draft fan innovation for heat recovery steam generators  

SciTech Connect

A first of its kind, induced draft (ID) heat recovery steam generators (HRSG) have been in service at a cogeneration facility since 1991. A preliminary engineering study considered a forced draft (FD) fan to supply combustion air to the HRSG duct burners (when the combustion turbine (CT) is out of service) as a traditional design; however, the study indicated that the FD fan may require the HRSG duct burner to be shut off following a CT trip and re-ignited after the FD fan was in service. Although the induced draft HRSG design cost more than the FD fan design, the induced draft design has improved the cogeneration facility's steam generation reliability by enabling the HRSG to remain in service following a CT trip. This paper briefly summarizes the preliminary engineering study that supported the decision to select the ID fan design. The paper also discusses the control system that operates the fresh-air louvers, duct burners, HRSG, and ID fan during a CT trip. Startup and operating experiences are presented that demonstrate the effectiveness of the design. Lessons learned are also summarized for input into future induced draft HRSG designs.

Beasley, O.W.; Hutchins, E.C. (Oklahoma Gas and Electric Co., Oklahoma City, OK (United States)); Predick, P.R.; Vavrek, J.M. (Sargent and Lundy, Chicago, IL (United States))

1994-04-01T23:59:59.000Z

119

Correlation of turbulent burning velocities of ethanol-air, measured in a fan-stirred bomb up to 1.2 MPa  

SciTech Connect

The turbulent burning velocity is defined by the mass rate of burning and this also requires that the associated flame surface area should be defined. Previous measurements of the radial distribution of the mean reaction progress variable in turbulent explosion flames provide a basis for definitions of such surface areas for turbulent burning velocities. These inter-relationships. in general, are different from those for burner flames. Burning velocities are presented for a spherical flame surface, at which the mass of unburned gas inside it is equal to the mass of burned gas outside it. These can readily be transformed to burning velocities based on other surfaces. The measurements of the turbulent burning velocities presented are the mean from five different explosions, all under the same conditions. These cover a wide range of equivalence ratios, pressures and rms turbulent velocities for ethanol-air mixtures. Two techniques are employed, one based on measurements of high speed schlieren images, the other on pressure transducer measurements. There is good agreement between turbulent burning velocities measured by the two techniques. All the measurement are generalised in plots of burning velocity normalised by the effective unburned gas rms velocity as a function of the Karlovitz stretch factor for different strain rate Markstein numbers. For a given value of this stretch factor a decrease in Markstein number increases the normalised burning velocity. Comparisons are made with the findings of other workers. (author)

Bradley, D.; Lawes, M.; Mansour, M.S. [School of Mechanical Engineering, University of Leeds (United Kingdom)

2011-01-15T23:59:59.000Z

120

Introduction of a Cooling Fan Efficiency Index  

E-Print Network (OSTI)

C F Cooling Effect (?t eq ) C F Fan Power, W (P f ) Cooling-Fan Efficiency (CFE) C/W F/Wand B. Jones. 1983. Ceiling fans as extenders of the summer

Schiavon, Stefano; Melikov, Arsen

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Cooling Tower Energy Conservation Through Hydraulic Fan Drives  

E-Print Network (OSTI)

Many companies offer gearboxes, shafts, and couplings for cooling tower fan drives, with little or no innovation. These companies have traditionally been purchased with an emphasis on cost and not "Return on Investment!" In the past, when energy conservation or "Return on Investment" was emphasized, the only alternative was to add an expensive frequency inverter for variable speed control. This meant expensive rewiring, placing additional controls in an already crowded control room, or constructing a special building for them. However, with H.E.M.'s patented Hydraulic Fan Drive, one receives variable speed control and more efficiency for approximately the price of a mechanical drive. The new, more efficient Hydraulic Drive allows for a variable speed control and the ability to sense water temperature to control fan speed.

Dickerson, J.

1991-06-01T23:59:59.000Z

122

Predicting of fan speed for energy saving in HVAC system based on adaptive network based fuzzy inference system  

Science Conference Proceedings (OSTI)

In this paper, a HVAC (heating, ventilating and air-conditioning) system has two different zones was designed and fan motor speed to minimize energy consumption of the HVAC system was controlled by a conventional (proportional-integral-derivative) PID ... Keywords: ANFIS, Air flow control, Energy saving, Fan motor speed predicting, HVAC system, PID control, Temperature control

Servet Soyguder; Hasan Alli

2009-05-01T23:59:59.000Z

123

The Internet World of Fan Fiction.  

E-Print Network (OSTI)

??Fan fiction, the most popular creative outlet for fans, allows the amateur writer an opportunity to be published and receive immediate feedback from peers. As (more)

Herzing, Melissa Jean

2008-01-01T23:59:59.000Z

124

Measured Natural Cooling Enhancement of a While House Fan  

E-Print Network (OSTI)

An experimental study was carried out in the summer of 1991 to investigate the natural cooling potential of use of a whole house fan in Central Florida's hot and humid climate. The residential building, in Cocoa Beach, FL, is typical of much of the existing housing stock in Florida: a concrete block structure with R-11 ceiling insulation. The building was ventilated with all windows open during the three month summer test period (June- August). Air temperatures and relative humidity inside the home interior along with exterior meteorological conditions (insolation, wind speed, air temperature, relative humidity) were scanned every five seconds with integrated averages recorded on a multi-channel data logger every 15- minutes. The house was naturally ventilated during the first half of summer. After a significant period of pre-retrofit summer data had been collected characterizing the building's thermal response, a 24" whole house fan was installed. The house was then force ventilated during evening hours for the remainder of the summer to establish potential of whole-house fans to improve interior comfort conditions. The electrical consumption of the fan was measured at both available fan speeds. Measurements revealed that the building interior was 3 - 6F cooler during the evening hours after the whole house fan was operated. However, data also showed that nighttime humidity levels rose: relative humidity increased from 74% to 83% during the nighttime period where fan-powered ventilation was used. Using the data results, an analysis was performed using Orlando, Florida TMY data to see how limits to whole house ventilation based on humidity and temperature conditions would affect the potential of such a cooling strategy.

Parker, D. S.

1994-01-01T23:59:59.000Z

125

Acceptance test report MICON software exhaust fan control modifications  

Science Conference Proceedings (OSTI)

This report documents the results the acceptance test HNF-4108 which verifies the MICON program changes for the new automatic transfer switch ATS-2 alarms, the Closed Loop Cooling isolator status, the CB-3 position alarm, the alarms for the new emergency fan damper backup air compressor, and the generator sequencer logic.

SILVAN, G.R.

1999-05-20T23:59:59.000Z

126

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network (OSTI)

CA. CEC(2008b). ResidentialAlternativeCalculationStandardforAirHandlersinResidentialSpaceConditioningofStandardsOptionsforResidentialAirHandlerFans.

Walker, Iain S.

2010-01-01T23:59:59.000Z

127

List of Compressed air Incentives | Open Energy Information  

Open Energy Info (EERE)

Energy Efficiency Incentive Program (Texas) Local Grant Program Texas Commercial Ceiling Fan Central Air conditioners Chillers Comprehensive MeasuresWhole Building Compressed air...

128

COOLING FAN AND SYSTEM PERFORMANCE AND EFFICIENCY IMPROVEMENTS  

Science Conference Proceedings (OSTI)

Upcoming emissions regulations (Tiers 3, 4a and 4b) are imposing significantly higher heat loads on the cooling system than lesser regulated machines. This work was a suite of tasks aimed at reducing the parasitic losses of the cooling system, or improving the design process through six distinct tasks: 1. Develop an axial fan that will provide more airflow, with less input power and less noise. The initial plan was to use Genetic Algorithms to do an automated fan design, incorporating forward sweep for low noise. First and second generation concepts could not meet either performance or sound goals. An experienced turbomachinery designer, using a specialized CFD analysis program has taken over the design and has been able to demonstrate a 5% flow improvement (vs 10% goal) and 10% efficiency improvement (vs 10% goal) using blade twist only. 2. Fan shroud developments, using an 'aeroshroud' concept developed at Michigan State University. Performance testing at Michigan State University showed the design is capable of meeting the goal of a 10% increase in flow, but over a very narrow operating range of fan performance. The goal of 10% increase in fan efficiency was not met. Fan noise was reduced from 0 to 2dB, vs. a goal of 5dB at constant airflow. The narrow range of fan operating conditions affected by the aeroshroud makes this concept unattractive for further development at this time 3. Improved axial fan system modeling is needed to accommodate the numbers of cooling systems to be redesigned to meet lower emissions requirements. A CFD fan system modeling guide has been completed and transferred to design engineers. Current, uncontrolled modeling practices produce flow estimates in some cases within 5% of measured values, and in some cases within 25% of measured values. The techniques in the modeling guide reduced variability to the goal of + 5% for the case under study. 4. Demonstrate the performance and design versatility of a high performance fan. A 'swept blade mixed flow' fan was rapid prototyped from cast aluminum for a performance demonstration on a small construction machine. The fan was mounted directly in place of the conventional fan (relatively close to the engine). The goal was to provide equal airflow at constant fan speed, with 75% of the input power and 5 dB quieter than the conventional fan. The result was a significant loss in flow with the prototype due to its sensitivity to downstream blockage. This sensitivity to downstream blockage affects flow, efficiency, and noise all negatively, and further development was terminated. 5. Develop a high efficiency variable speed fan drive to replace existing slipping clutch style fan drives. The goal for this task was to provide a continuously variable speed fan drive with an efficiency of 95%+ at max speed, and losses no greater than at max speed as the fan speed would vary throughout its entire speed range. The process developed to quantify the fuel savings potential of a variable speed fan drive has produced a simple tool to predict the fuel savings of a variable speed drive, and has sparked significant interest in the use of variable speed fan drive for Tier 3 emissions compliant machines. The proposed dual ratio slipping clutch variable speed fan drive can provide a more efficient system than a conventional single ratio slipping clutch fan drive, but could not meet the established performance goals of this task, so this task was halted in a gate review prior to the start of detailed design. 6. Develop a cooling system air filtration device to allow the use of automotive style high performance heat exchangers currently in off road machines. The goal of this task was to provide a radiator air filtration system that could allow high fin density, louvered radiators to operate in a find dust application with the same resistance to fouling as a current production off-road radiator design. Initial sensitivity testing demonstrated that fan speed has a significant impact on the fouling of radiator cores due to fine dusts, so machines equipped with continuously variabl

Ronald Dupree

2005-07-31T23:59:59.000Z

129

Performance of ECM controlled VAV fan powered terminal units  

E-Print Network (OSTI)

Empirical performance models of fan airflow, primary airflow and power consumption were developed for series and parallel variable air volume fan powered terminal units. An experimental setup and test procedure were created to test the terminal units at typical design pressures and airflows. Each terminal unit observed in this study used an 8 in (20.3 cm) primary air inlet. Two fan motor control methods were considered. The primary control of interest was the electronically commutated motor (ECM) controller. Data collected were compared with previous research regarding silicon rectified control (SCR) units. Generalized models were developed for both series and parallel terminal units. Coefficients for performance models were then compared with comparable SCR controlled units. Non-linear statistical modeling was performed using SPSS software (2008). In addition to airflow and power consumption modeling, power quality was also quantified. Relationships between real power (watts) and apparent power (VA) were presented as well as harmonic frequencies and total harmonic distortion. Power quality was recorded for each ECM controlled terminal unit tested. Additional tests were also made to SCR controlled terminal units used in previous research (Furr 2006). The airflow and power consumption performance models had an R2 equal to 0.990 or greater for every terminal unit tested. An air leakage model was employed to account for leakage in the parallel designed VAV terminal units when the internal fan was turned off. For the leakage model, both ECM and SCR controlled units achieved an R2 greater than or equal to 0.918.

Cramlet, Andrew Charles

2008-08-01T23:59:59.000Z

130

Structure, optical, and electrical properties of indium tin oxide thin films prepared by sputtering at room temperature and annealed in air or nitrogen  

Science Conference Proceedings (OSTI)

Indium tin oxide (ITO) thin films have been grown onto soda-lime glass substrates by sputtering at room temperature with various oxygen to argon partial pressure ratios. After deposition, the samples have been annealed at temperatures ranging from 100 to 500 degree sign C in nitrogen or in air. The structure, optical, and electrical characteristics of the ITO coatings have been analyzed as a function of the deposition and the annealing parameters by x-ray diffraction, spectrophotometry, and Hall effect measurements. It has been found that the as-grown amorphous layers crystallize in the cubic structure by heating above 200 degree sign C. Simultaneously, the visible optical transmittance increases and the electrical resistance decreases, in proportions that depend mainly on the sputtering conditions. The lowest resistivity values have been obtained by annealing at 400 degree sign C in nitrogen, where the highest carrier concentrations are achieved, related to oxygen vacancy creation. Some relationships between the analyzed properties have been established, showing the dependence of the cubic lattice distortion and the infrared optical characteristics on the carrier concentration.

Guillen, C.; Herrero, J. [Departamento de Energia, CIEMAT, Avda Complutense 22, 28040 Madrid (Spain)

2007-04-01T23:59:59.000Z

131

title Potential Global Benefits of Improved Ceiling Fan Energy...  

NLE Websites -- All DOE Office Websites (Extended Search)

Fan Energy Efficiency year month keywords bottom up Ceiling fan Celing Fans efficiency energy efficiency Financial incentives Market Transformation residential Standards and...

132

Development and Analysis of Desiccant Enhanced Evaporative Air...  

NLE Websites -- All DOE Office Websites (Extended Search)

NREL National Renewable Energy Laboratory OA outdoor air P amb ambient pressure (psi) P fan fan power (kW) v PP polypropylene Q cooling total cooling (kW or Btuh) Q latent latent...

133

Cold Air Distribution in Office Buildings: Technology Assessment for California  

E-Print Network (OSTI)

in DOE-2, an oversized cooling tower with two-speed fans iscooling, and dry cooling towers to provide 55"F supply air.for the compressors and cooling tower fans exceed that of

Bauman, F.S.

2008-01-01T23:59:59.000Z

134

Cold air distribution in office buildings: technology assessment for califonia  

E-Print Network (OSTI)

in DOE-2, an oversized cooling tower with two-speed fans iscooling, and dry cooling towers to provide 55F supply air.for the compressorsand cooling tower fans exceeds that of

Bauman, Fred; Borgers, T.; LaBerge, P.; Gadgil, A.

1993-01-01T23:59:59.000Z

135

Experimental Evaluation of Installed Cooking Exhaust Fan Performance  

NLE Websites -- All DOE Office Websites (Extended Search)

Experimental Evaluation of Installed Cooking Exhaust Fan Performance Experimental Evaluation of Installed Cooking Exhaust Fan Performance Title Experimental Evaluation of Installed Cooking Exhaust Fan Performance Publication Type Report LBNL Report Number LBNL-4183E Year of Publication 2010 Authors Singer, Brett C., William W. Delp, and Michael G. Apte Publisher Lawrence Berkeley National Laboratory City Berkeley Keywords airflow & pollutant transport group, cooktop, energy analysis and environmental impacts department, gas burners, indoor air quality, indoor environment department, kitchen, nitrogen dioxide, oven, pollutant emissions, range hood, residential, source control, task ventilation, technology, sustainability and impact assessment group Abstract The installed performance of cooking exhaust fans was evaluated through residential field experiments conducted on a sample of 15 devices varying in design and other characteristics. The sample included two rear downdraft systems, two under-cabinet microwave over range (MOR) units, three different installations of an under-cabinet model with grease screens across the bottom and no capture hood, two devices with grease screens covering the bottom of a large capture hood (one under-cabinet, one wall-mount chimney), four under-cabinet open hoods, and two open hoods with chimney mounts over islands. Performance assessment included measurement of airflow and sound levels across fan settings and experiments to quantify the contemporaneous capture efficiency for the exhaust generated by natural gas cooking burners. Capture efficiency is defined as the fraction of generated pollutants that are removed through the exhaust and thus not available for inhalation of household occupants. Capture efficiency (CE) was assessed for various configurations of burner use (e.g. single front, single back, combination of one front and one back, oven) and fan speed setting. Measured airflow rates were substantially lower than the levels noted in product literature for many of the units. This shortfall was observed for several units costing in excess of $1000. Capture efficiency varied widely (from <5% to roughly 100%) across devices and across conditions for some devices. As expected, higher capture efficiencies were achieved with higher fan settings and the associated higher air flow rates. In most cases, capture efficiencies were substantially higher for rear burners than for front burners. The best and most consistent performance was observed for open hoods that covered all cooktop burners and operated at higher airflow rates. The lowest capture efficiencies were measured when a front burner was used with a rear backdraft system or with lowest fan setting for above the range systems that do not cover the front burners.

136

Ceiling Fan and Ceiling Fan Light Kit use in the U.S. Results of a Survey on Amazon Mechanical Turk  

E-Print Network (OSTI)

Ceiling Fan and Ceiling Fan Light Kit use in the U.S. Ceiling Fan and Ceiling Fan Light Kit use in the U.S. fans and ceiling fan light kits in the United States (

Kantner, Colleen L.S.

2013-01-01T23:59:59.000Z

137

Sound maintenance practices protect fan investments  

Science Conference Proceedings (OSTI)

Since underground coal miners depend on axial fans, lack of maintenance could prove costly. A number of pre-emptive actions that can help keep fans running at optimal performance can also be taken. 2 photos.

Bauer, M.

2009-11-15T23:59:59.000Z

138

Engine having hydraulic and fan drive systems using a single high pressure pump  

DOE Patents (OSTI)

An engine comprises a hydraulic system attached to an engine housing that includes a high pressure pump and a hydraulic fluid flowing through at least one passageway. A fan drive system is also attached to the engine housing and includes a hydraulic motor and a fan which can move air over the engine. The hydraulic motor includes an inlet fluidly connected to the at least one passageway.

Bartley, Bradley E. (Manito, IL); Blass, James R. (Bloomington, IL); Gibson, Dennis H. (Chillicothe, IL)

2000-01-01T23:59:59.000Z

139

Solar Buildings: Transpired Air Collectors  

DOE Green Energy (OSTI)

Transpired air collectors preheat building ventilation air by using the building's ventilation fan to draw fresh air through the system. The intake air is heated as it passes through the perforated absorber plate and up the plenum between the absorber and the south wall of the building. Reduced heating costs will pay for the systems in 3--12 years.

NONE

1998-11-24T23:59:59.000Z

140

Experimental Evaluation of Installed Cooking Exhaust Fan Performance  

SciTech Connect

The installed performance of cooking exhaust fans was evaluated through residential field experiments conducted on a sample of 15 devices varying in design and other characteristics. The sample included two rear downdraft systems, two under-cabinet microwave over range (MOR) units, three different installations of an under-cabinet model with grease screens across the bottom and no capture hood, two devices with grease screens covering the bottom of a large capture hood (one under-cabinet, one wall-mount chimney), four under-cabinet open hoods, and two open hoods with chimney mounts over islands. Performance assessment included measurement of airflow and sound levels across fan settings and experiments to quantify the contemporaneous capture efficiency for the exhaust generated by natural gas cooking burners.Capture efficiency is defined as the fraction of generated pollutants that are removed through the exhaust and thus not available for inhalation of household occupants. Capture efficiency (CE) was assessed for various configurations of burner use (e.g., single front, single back, combination of one front and one back, oven) and fan speed setting. Measured airflow rates were substantially lower than the levels noted in product literature for many of the units. This shortfall was observed for several units costing in excess of $1000. Capture efficiency varied widely (from<5percent to roughly 100percent) across devices and across conditions for some devices. As expected, higher capture efficiencies were achieved with higher fan settings and the associated higher air flow rates. In most cases, capture efficiencies were substantially higher for rear burners than for front burners. The best and most consistent performance was observed for open hoods that covered all cooktop burners and operated at higher airflow rates. The lowest capture efficiencies were measured when a front burner was used with a rear backdraft system or with lowest fan setting for above the range systems that do not cover the front burners.

Singer, Brett C.; Delp, William W.; Apte, Michael G.

2010-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Predictions of thermal comfort and pollutant distributions for a thermostatically-controlled, air-conditioned, partitioned room: Numerical results and enhanced graphical presentation  

SciTech Connect

An index of local thermal comfort and pollutant distributions have been computed with the TEMPEST computer code, in a transient simulation of an air-conditioned enclosure with an incomplete partition. This complex three-dimensional air conditioning problem included forced ventilation through inlet veins, flow through a partition, remote return air vents, and infiltration source, a pollutant source, and a thermostatically controlled air conditioning system. Five forced ventilation schemes that varied in vent areas and face velocities were simulated. Thermal comfort was modeled as a three-dimensional scalar field dependent on the fluid velocity and temperature fields; where humidity activity levels, and clothing were considered constants. Pollutants transport was incorporated through an additional constituent diffusion equation. Six distinct graphic techniques for the visualization of the three-dimensional data fields of air velocity, temperature, and comfort index were tested. 4 refs., 7 figs., 1 tab.

White, M.D.; Eyler, L.L.

1989-05-01T23:59:59.000Z

142

Knowing fans, knowing music : an exploration of fan interaction on Twitter  

E-Print Network (OSTI)

know many local Ritter fans yet 26 She responded about aI see you're a Buffy fanare you also a Browncoat? : )The term Browncoats refers to fans of the short-lived sci-fi

McCollum, Nick

2011-01-01T23:59:59.000Z

143

Submitting Organization Hongyou Fan Sandia National Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

&24; 2007 R&D 100 Award Entry Form &24; Submitting Organization Hongyou Fan Sandia National Laboratories Advanced Materials Laboratory 1001 University Boulevard SE Albuquerque, NM...

144

Active Noise Control of a Radial Fan.  

E-Print Network (OSTI)

??This thesis work aims at investigating the use of an active noise control (ANC) system on a radial fan. This was done by studying the (more)

Murthy, Muddala

2009-01-01T23:59:59.000Z

145

Portable oven air circulator  

DOE Patents (OSTI)

A portable air circulating apparatus for use in cooking ovens which is used to create air currents in the oven which transfer heat to cooking foodstuffs to promote more rapid and more uniform cooking or baking, the apparatus including a motor, fan blade and housing of metallic materials selected from a class of heat resistant materials.

Jorgensen, Jorgen A. (Bloomington, MN); Nygren, Donald W. (Minneapolis, MN)

1983-01-01T23:59:59.000Z

146

Advanced Energy-Efficient Filtration: Fan Filter Unit  

E-Print Network (OSTI)

Efficient Fan- Filter Units, Proceedings of SEMI TechnicalFor Evaluating Fan-Filter Unit Performance Applications inPerformance of Fan-Filter Units, Version 1.2 (2004, public

Xu, Tengfang

2005-01-01T23:59:59.000Z

147

Advanced Energy-Efficient Filtration: Fan Filter Unit  

E-Print Network (OSTI)

Cleanrooms: Energy Efficient Fan- Filter Units, ProceedingsStandard Method For Evaluating Fan-Filter Unit Performance Energy Performance of Fan-Filter Units, Version 1.2 (2004,

Xu, Tengfang

2005-01-01T23:59:59.000Z

148

Best Practice for Energy Efficient Cleanrooms: Fan-Filter Units  

E-Print Network (OSTI)

control F iltra ti on ? Fan Efficiency ? Right Sizing ?Energy Performance of Fan-Filte r Units, Version 1.3 (2005),RP36.1 (Draft). Testing Fan-Filter Units. Draft Recommended

Xu, Tengfang

2005-01-01T23:59:59.000Z

149

The Effect of Inlet Flow Profile Distortion on Fan Performance  

Science Conference Proceedings (OSTI)

Performance tests on fans for utility and industrial applications are based on codes that expect a relatively uniform velocity profile at the fan inlet. Unfortunately, when fans scaled up from the ideal model fans are installed in actual utility and industrial applications, non-uniform or distorted flow patterns often occur at the inlet of the fan. This project sought to determine and, if possible, quantify the effect on fan performance of distorted inlet flow profiles. A second goal was to determine whe...

2010-02-22T23:59:59.000Z

150

Operation and Maintenance Guidelines for Draft Fans  

Science Conference Proceedings (OSTI)

The reliability, efficiency, and safety of draft fans in fossil fuel power plants depend on effective operating and maintenance practices. These guidelines systematically present state-of-the-art techniques that utility personnel can use in operation, maintenance, troubleshooting, inspection, and weld repair of major fan components and auxiliary systems.

1999-05-13T23:59:59.000Z

151

Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles  

E-Print Network (OSTI)

Most air handling units (AHUs) in commercial buildings have an air economizer cycle for free cooling under certain outside air conditions. During the economizer cycle, the outside air and return air dampers are modulated to seek mixing air temperature at supply air temperature setpoint. Mechanical cooling is always required when outside air temperature is higher than the supply air temperature setpoint. Generally the supply air temperature setpoint is set at 55F for space humidity control. Actually the dehumidification is not necessary when outside air dew point is less than 55F. Meanwhile the space may have less cooling load due to envelope heat loss and/or occupant schedule. These provide an opportunity to use higher supply air temperature to reduce or eliminate mechanical cooling and terminal box reheat. On the other hand the higher supply air temperature will require higher air flow as well as higher fan power. Therefore the supply air temperature has to be optimized to minimize the combined energy for fan, cooling and heating energy. In this paper a simple energy consumption model is established for AHU systems during the economizer and then a optimal supply air temperature control is developed to minimize the total cost of the mechanical cooling and the fan motor power. This paper presents AHU system energy modeling, supply air temperature optimization, and simulated energy savings.

Xu, K.; Liu, M.; Wang, G.; Wang, Z.

2007-01-01T23:59:59.000Z

152

Redesign of ceiling fan - adapted to the Scandinavian market.  

E-Print Network (OSTI)

?? The master degree thesis project, at Halmstad University, was made in cooperation with Hunter Fan, one of the leading fan companies on the American (more)

Eliasson, Anna

2007-01-01T23:59:59.000Z

153

Potential Global Benefits of Improved Ceiling Fan Energy Efficiency  

NLE Websites -- All DOE Office Websites (Extended Search)

Global Benefits of Improved Ceiling Fan Energy Efficiency Title Potential Global Benefits of Improved Ceiling Fan Energy Efficiency Publication Type Report LBNL Report Number...

154

Fan-fold shielded electrical leads  

DOE Patents (OSTI)

Disclosed are fan-folded electrical leads made from copper cladded Kapton, for example, with the copper cladding on one side serving as a ground plane and the copper cladding on the other side being etched to form the leads. The Kapton is fan folded with the leads located at the bottom of the fan-folds. Electrical connections are made by partially opening the folds of the fan and soldering, for example, the connections directly to the ground plane and/or the lead. The fan folded arrangement produces a number of advantages, such as electrically shielding the leads from the environment, is totally non-magnetic, and has a very low thermal conductivity, while being easy to fabricate. 3 figs.

Rohatgi, R.R.; Cowan, T.E.

1996-06-11T23:59:59.000Z

155

Fan-fold shielded electrical leads  

DOE Patents (OSTI)

Fan-folded electrical leads made from copper cladded Kapton, for example, with the copper cladding on one side serving as a ground plane and the copper cladding on the other side being etched to form the leads. The Kapton is fan folded with the leads located at the bottom of the fan-folds. Electrical connections are made by partially opening the folds of the fan and soldering, for example, the connections directly to the ground plane and/or the lead. The fan folded arrangement produces a number of advantages, such as electrically shielding the leads from the environment, is totally non-magnetic, and has a very low thermal conductivity, while being easy to fabricate.

Rohatgi, Rajeev R. (Mountain View, CA); Cowan, Thomas E. (Livermore, CA)

1996-01-01T23:59:59.000Z

156

State-of-the-Art in Residential and Small Commercial Air HandlerPerformance  

SciTech Connect

Although furnaces, air conditioners, and heat pumps have become significantly more efficient over the last couple of decades, residential air handlers have typical efficiencies of only 10% to 15% due to poor electric motor and aerodynamic performance. These low efficiencies indicate that there is significant room for improvement of air handler fans. The other 85-90% of the electricity used by air handlers is manifested as heat. This extra heat reduces air conditioning cooling and dehumidification performance and effectively acts as fuel switching for fossil fueled furnaces. For electric furnaces, this heat substitutes directly for the electric resistance heating elements. For heat pumps, this heat substitutes for compressor-based high COP heating and effectively reduces the COP of the heat pump. Using a combination of field observations and engineering judgment they can assemble a list of the problems that lead to low air handler efficiency and potential solutions to these problems, as shown. None of the problems require exotic or complex solutions and there are no technological barriers to adopting them. Some of the solutions are simple equipment swaps (using better electric motors), others require changes to the way the components are built (tighter tolerances) and other relate to HVAC equipment design (not putting large fans in small cabinets).

Walker, Iain S.

2005-03-01T23:59:59.000Z

157

Parametric System Curves: Correlations Between Fan Pressure Rise and Flow for Large Commercial Buildings  

SciTech Connect

A substantial fraction of HVAC energy use in large commercial buildings is due to fan operation. Fan energy use depends in part on the relationship between system pressure drop and flow through the fan, which is commonly called a "system curve." As a step toward enabling better selections of air-handling system components and analyses of common energy efficiency measures such as duct static pressure reset and duct leakage sealing, this paper shows that a simple four-parameter physical model can be used to define system curves. Our model depends on the square of the fan flow, as is commonly considered. It also includes terms that account for linear-like flow resistances such as filters and coils, and for supply duct leakage when damper positions are fixed or are changed independently of static pressure or fan flow. Only two parameters are needed for systems with variable-position supply dampers (e.g., VAV box dampers modulating to control flow). For these systems, reducing or eliminating supply duct leakage does not change the system curve. The parametric system curve may be most useful when applied to field data. Non-linear techniques could be used to fit the curve to fan pressure rise and flow measurements over a range of operating conditions. During design, when measurements are unavailable, one could use duct design calculation tools instead to determine the coefficients.

Sherman, Max; Wray, Craig

2010-05-19T23:59:59.000Z

158

Review of air flow measurement techniques  

SciTech Connect

Airflow measurement techniques are necessary to determine the most basic of indoor air quality questions: ''Is there enough fresh air to provide a healthy environment for the occupants of the building?'' This paper outlines airflow measurement techniques, but it does not make recommendations for techniques that should be used. The airflows that will be discussed are those within a room or zone, those between rooms or zones, such as through doorways (open or closed) or passive vents, those between the building and outdoors, and those through mechanical air distribution systems. Techniques that are highlighted include particle streak velocimetry, hot wire anemometry, fan pressurization (measuring flow at a given pressure), tracer gas, acoustic methods for leak size determination, the Delta Q test to determine duct leakage flows, and flow hood measurements. Because tracer gas techniques are widely used to measure airflow, this topic is broken down into sections as follows: decay, pulse injection, constant injection, constant concentration, passive sampling, and single and multiple gas measurements for multiple zones.

McWilliams, Jennifer

2002-12-01T23:59:59.000Z

159

Experimental Evaluation of Installed Cooking Exhaust Fan Performance  

Science Conference Proceedings (OSTI)

The installed performance of cooking exhaust fans was evaluated through residential field experiments conducted on a sample of 15 devices varying in design and other characteristics. The sample included two rear downdraft systems, two under-cabinet microwave over range (MOR) units, three different installations of an under-cabinet model with grease screens across the bottom and no capture hood, two devices with grease screens covering the bottom of a large capture hood (one under-cabinet, one wall-mount chimney), four under-cabinet open hoods, and two open hoods with chimney mounts over islands. Performance assessment included measurement of airflow and sound levels across fan settings and experiments to quantify the contemporaneous capture efficiency for the exhaust generated by natural gas cooking burners.Capture efficiency is defined as the fraction of generated pollutants that are removed through the exhaust and thus not available for inhalation of household occupants. Capture efficiency (CE) was assessed for various configurations of burner use (e.g., single front, single back, combination of one front and one back, oven) and fan speed setting. Measured airflow rates were substantially lower than the levels noted in product literature for many of the units. This shortfall was observed for several units costing in excess of $1000. Capture efficiency varied widely (fromfan settings and the associated higher air flow rates. In most cases, capture efficiencies were substantially higher for rear burners than for front burners. The best and most consistent performance was observed for open hoods that covered all cooktop burners and operated at higher airflow rates. The lowest capture efficiencies were measured when a front burner was used with a rear backdraft system or with lowest fan setting for above the range systems that do not cover the front burners.

Singer, Brett C.; Delp, William W.; Apte, Michael G.

2010-11-01T23:59:59.000Z

160

Power Reduction Scheme of Fans in a Blade System by Considering the Imbalance of CPU Temperatures  

Science Conference Proceedings (OSTI)

In order to develop a data center power efficiency index, we built a test bed of a data center and measured power components and environmental variables in some detail, including the power consumption and temperature of each node, rack and air conditioning ... Keywords: Data center, Power consumption, Power efficiency, CPU temperature, Fan speed

Yuetsu Kodama; Satoshi Itoh; Toshiyuki Shimizu; Satoshi Sekiguchi; Hiroshi Nakamura; Naohiko Mori

2010-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Ceiling Fan and Ceiling Fan Light Kit use in the U.S. Results of a Survey on Amazon Mechanical Turk  

E-Print Network (OSTI)

Intellect, LLC (2011). Ceiling fan consumer survey data fromconsumption from ceiling fans. 5 References Amazon.com. (January/February 2001). Ceiling fans: Fulfilling the energy

Kantner, Colleen L.S.

2013-01-01T23:59:59.000Z

162

Modeling of Electronically Commutated Motor Controlled Fan-powered Terminal Units  

E-Print Network (OSTI)

Empirical models of airflow and power consumption were developed for series and parallel variable air volume fan powered terminal units (FPTUs). An experimental setup and test procedure were developed to test the terminal units over typical operating ranges. The terminal units in this study used either an 8 in. (20.32 cm) or a 12 in. (30.48 cm) primary air inlet. All terminal units utilized electronically commutated motor (ECM) controllers. Data collected were compared against previous data collected for silicon controlled rectifier (SCR) units. Generalized models were developed for both series and parallel units, and compared against models developed for SCR units. In addition to the performance modeling, power factor and power quality data were also collected for each terminal unit. The power quality analysis included recording and analyzing harmonic distortion for current, voltage, and power up to the 25th harmonic. The total harmonic distortion (THD) was also recorded and presented. For the series terminal units, models were developed for fan airflow, fan power, and primary airflow. The models for fan airflow all had R2 values above 0.987. The models for fan power all had R2 values above 0.968. The models for primary airflow all had R2 values above 0.895. For the parallel terminal units, models were developed for leakage, fan airflow, fan power, and primary airflow. All of the leakage models had R2 values above 0.826. All of the fan airflow models had R2 values above 0.955. All of the fan power models had R2 values above 0.922. All of the primary airflow models had R2 values above 0.872. The real power THD was below 1.5 percent for both series and parallel FPTUs. The current THD ranged from 84 percent to 172 percent for series FPTUs and from 83 percent to 183 percent for parallel FPTUs. The voltage THD was below 1.4 percent for both series and parallel FPTUs. The performance models developed will help improve the accuracy of building energy simulation programs for heating, ventilation, and air conditioning (HVAC) systems utilizing ECM controlled FPTUs. Increasing the accuracy of these simulations will allow HVAC system designers to better optimize their designs for specific building types in a wide variety of climates.

Edmondson, Jacob Lee

2009-12-01T23:59:59.000Z

163

Integrated Ice Storage/Sprinkler HVAC System Sharply Cuts Energy Costs and Air-Distribution First Costs  

E-Print Network (OSTI)

Integrated ice thermal storage/sprinkler HVAC systems developed and applied by the author in several commercial applications shift a major portion of electric utility demand to cheaper off-peak hours, while also reducing significantly the first cost of distribution ductwork. Savings of up to 80% in primary duct and air handler costs (compared to a traditional all-air HVAC system) partially offset the first cost of ice storage equipment, which in turn permits a 50% reduction in utility energy costs for air conditioning in some facilities. The basic ice storage/sprinkler HVAC system is described as well as optional subsystems, such as cogeneration, that are cost-effective under certain conditions. The system's design parameters, psychrometric process, and thermodynamic characteristics are presented and two installations are described, a 223,000-sq ft shopping center and a 150,000-sq ft, two-story retail store. Reductions in the size and first cost of primary air-handling equipment and ductwork are achieved by distributing a small quantity (0.1 to 0.2 cfm/sq ft) of very dry, 40F primary air. All dehumidification is handled by the ice-chilled primary air, which is distributed in variable, volume, determined by the space dehumidification requirement, to fan-coil induction terminal units. The primary air is mixed with fan-induced room air in the terminals prior to distribution to the space at a constant volume. The fan-induction terminals contain cooling coils connected to the integrated sprinkler system, which circulates chilled water from the central plant through the coils when additional sensible cooling is required. This chilled water is at a thermodynamically efficient elevated temperature (58-68F), since it handles sensible cooling load only.

Meckler, G.

1986-01-01T23:59:59.000Z

164

Technical support document: Energy efficiency standards for consumer products: Room air conditioners, water heaters, direct heating equipment, mobile home furnaces, kitchen ranges and ovens, pool heaters, fluorescent lamp ballasts and television sets. Volume 1, Methodology  

SciTech Connect

The Energy Policy and Conservation Act (P.L. 94-163), as amended, establishes energy conservation standards for 12 of the 13 types of consumer products specifically covered by the Act. The legislation requires the Department of Energy (DOE) to consider new or amended standards for these and other types of products at specified times. DOE is currently considering amending standards for seven types of products: water heaters, direct heating equipment, mobile home furnaces, pool heaters, room air conditioners, kitchen ranges and ovens (including microwave ovens), and fluorescent light ballasts and is considering establishing standards for television sets. This Technical Support Document presents the methodology, data, and results from the analysis of the energy and economic impacts of the proposed standards. This volume presents a general description of the analytic approach, including the structure of the major models.

Not Available

1993-11-01T23:59:59.000Z

165

Fan System Assessment - End User Training | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fan System Assessment - End User Training Fan System Assessment - End User Training Fan System Assessment - End User Training December 18, 2013 7:30AM to 4:30PM EST Boise, Idaho Optimizing industrial fan systems can take on many forms, but any fan optimization project must meet the needs of the process. This self-paced workshop highlights the benefits of fan system optimization and examines fan system performance characteristics and practical issues concerning measurement data. The session introduces the FSAT software. This powerful analysis software helps you quantify the potential benefits of configuring fan systems for optimal performance, calculate the amount of energy use by your fan system, and estimate fan system efficiency. Learn how the software works, what data is required for FSAT, and how to interpret assessment

166

Laugh out loud in real life : women's humor and fan identity; Women's humor and fan identity.  

E-Print Network (OSTI)

??The emerging field of fan studies has, until recently, been defined only by the research that has taken place within it. Almost universally, this research (more)

Klink, Madeline LeNore

2010-01-01T23:59:59.000Z

167

Fanning the Flames of Romance: An Exploration of Fan Fiction and the Romance Novel.  

E-Print Network (OSTI)

??Fan fiction and romance novels constitute two bodies of romantic literature being produced for and by women within dramatically different environments. The purpose of this (more)

Morrissey, Katherine

168

Evaluation of the cooling fan efficiency index.  

E-Print Network (OSTI)

between the cooling effect (measured with a thermal manikin)output is the body cooling effect [5]. Thermal manikins withThermal manikins can be used to measure the fan cooling

Schiavon, Stefano; Melikov, Arsen

2009-01-01T23:59:59.000Z

169

Advanced Manufacturing Office: Training: Fan Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

the tool and presents the basics-and the benefits-of using it to target opportunities for energy savings in your plant. Fan System Assessment - self-paced workshop Availability:...

170

The effects of roof reflectance on air temperatures surrounding...  

NLE Websites -- All DOE Office Websites (Extended Search)

the heating of condenser inlet air by the roof, and to assess the effects of condenser fan operation on the potential recirculation of hot discharge air from the condenser. The...

171

Modeling of ECM Controlled Series Fan-powered VAV Terminal Units  

E-Print Network (OSTI)

Semi-empirical models for series fan-powered variable air volume terminal units (FPTUs) were developed based on models of the primary, plenum, fan airflow and the fan power consumption. The experimental setups and test procedures were developed respectively for primary, plenum and fan airflow to test each component of the FPTUs at typical design pressures and airflows. Two sizes of the terminal units from three manufacturers were used in this study. All of the FPTUs were equipped with electronically commutated motors (ECM). Data provided by the models were compared against the data from previous experiments to prove the models validity. Regression modeling was performed by using SigmaStat. The model of primary airflow had an R2 above 0.948 for all the terminal units evaluated while the plenum airflow model had an R2 above 0.99. For all the terminal units, the R2 of the fan airflow model was ranged from 0.973 to 0.998. Except for one fan, the fan power consumption model was able to characterize the power performance and had an R2 above 0.986. By combining the airflow and power models, the model for series FPTU was developed. Verification was made to prove the FPTU models validity by comparing the measured and predicted data of airflow and power consumption. Correction factors were used in the primary airflow model to compensate for the difference caused by large measurement errors and the system effects. The predicted values were consistent with measurements and no offset was needed in the primary airflow model. Generally, the newly established model was able to describe the airflow performance as well as power consumption of series FPTUs without adding complexity.

Yin, Peng

2010-08-01T23:59:59.000Z

172

Ventilation Controller for Improved Indoor Air Quality  

Iain Walker and colleagues at Berkeley Lab have developed a dynamic control system for whole-house ventilation fans that provides maximal air quality while reducing by 18-44% the energy spent on ventilation. The system, the Residential Integrated ...

173

An Innovative Method for Dynamic Characterization of Fan Filter Unit Operation.  

E-Print Network (OSTI)

Filtration: Fan filter units. Final Report, LawrencePerformance of Fan Filter Units, Version 1.3. BerkeleyEfficient Fan filter units, Proceedings of Semiconductor

Xu, Tengfang

2006-01-01T23:59:59.000Z

174

Uranium-series comminution ages of continental sediments: Case study of a Pleistocene alluvial fan  

E-Print Network (OSTI)

of a stream-dominated alluvial fan, San Joaquin valley,on Quaternary fluvial fans, San Joaquin Basin, California,M. , (Eds), Alluvial Fans: Geomorphology, Sedimentology,

Lee, Victoria E.

2010-01-01T23:59:59.000Z

175

An Innovative Method for Dynamic Characterization of Fan Filter Unit Operation.  

E-Print Network (OSTI)

Laboratory Methods of Testing Fans for Rating. ASHRAE. 1987.Efficient Filtration: Fan filter units. Final Report,Energy Performance of Fan Filter Units, Version 1.3.

Xu, Tengfang

2006-01-01T23:59:59.000Z

176

Coarse-clastic turbidite sedimentation : the neoproterozoic Imsdalen submarine fan complex, Hedmark Basin, South Norway.  

E-Print Network (OSTI)

??The Imsdalen Submarine Fan Complex is a gravel and coarse sand dominated turbidite fan system. The fan complex was deposited in the Neoproterozoic Hedmark rift (more)

Stalsberg, Martin

2004-01-01T23:59:59.000Z

177

Matchstick: a room-to-room thermal model for predicting indoor temperature from wireless sensor data  

Science Conference Proceedings (OSTI)

In this paper we present a room-to-room thermal model used to accurately predict temperatures in residential buildings. We evaluate the accuracy of this model with ground truth data from four occupied family homes (two in the UK and two in the US). The ... Keywords: forced air, home automation, prediction, radiators, thermal modelling, underfloor heating

Carl Ellis; Mike Hazas; James Scott

2013-04-01T23:59:59.000Z

178

Fan blade development. Final report Sep 81-Sep 82  

SciTech Connect

The objective of this program was to develop an improved fan blade that could be utilized in place of the current steel fan blade on the Pedal Ventilator Kit (PVK). The goals of the program were to reduce both the unit cost and weight of the fan while maintaining its effectiveness and reliability. A value analysis study was conducted on the fan blade to determine material/design revisions that offered potential manufacturing economies. Based on the conclusions of the study, two designs were chosen for fabrication. The two fan designs were constructed and tested. As a result of the performance testing, one fan blade emerged as the optimum design. Fifteen fan blades of the optimum design were constructed for FEMA inspection and distribution. Preliminary specifications were generated for the fan blade assembly. in addition, production cost estimates based on a procurement of 100,000 units were formulated for FEMA budgetary purposes.

Buday, J.M.

1982-09-01T23:59:59.000Z

179

Laboratory evaluation of fan/filter units' aerodynamic and energy performance  

E-Print Network (OSTI)

such as motor types, fan wheels, design, and orientations ofventilation system design, testing of fans and ventilation

Xu, Tengfang; Jeng, Ming-Shan

2004-01-01T23:59:59.000Z

180

Fan Blade Fracture in a Welded Assembly - Programmaster.org  

Science Conference Proceedings (OSTI)

About this Abstract. Meeting, Materials Science & Technology 2013. Symposium, Failure Analysis and Prevention. Presentation Title, Fan Blade Fracture in a...

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

SRO : single room occupancy  

E-Print Network (OSTI)

During August of 1996, I stayed in a series of SRO hotels in New York City leaving a book and diary behind when I checked out of each room. The books that were left in the rooms differ from one room to the other but all ...

Shimada, Taketo

1997-01-01T23:59:59.000Z

182

HEPA Filter Differential Pressure Fan Interlock System Functional Requirements and Technical Design Criteria  

SciTech Connect

Double-shell tanks (DSTs) and Double Contained Receiver Tanks (DCRTs) are actively ventilated, along with certain single-shell tanks (SSTs) and other RPP facilities. The exhaust air stream on a typical primary ventilation system is drawn through two stages of high-efficiency particulate air (HEPA) filtration to ensure confinement of airborne radioactive materials. Active ventilation exhaust stacks require a stack CAM interlock to detect releases from postulated accidents, and to shut down the exhaust fan when high radiation levels are detected in the stack airstream. The stack CAM interlock is credited as a mitigating control to stop continued unfiltered radiological and toxicological discharges from the stack, which may result from an accident involving failure of a HEPA filter. This document defines the initial technical design baseline for a HEPA filter AP fan interlock system.

TUCK, J.A.

2000-05-11T23:59:59.000Z

183

TR-034 Geomorphology March 2006 Coastal fan destabilization  

E-Print Network (OSTI)

the watershed boundary). 3.0 STUDY DESIGN AND METHODS To evaluate fans from a broad range of coastal conditionsTR-034 Geomorphology March 2006 Coastal fan destabilization and forest management by T.H. Millard Columbia V9L 1V2 Citation: Millard, T.H., D.J. Wilford and M.E. Oden. 2006. Coastal fan destabilization

184

Recent Sediments of the Monterey Deep-Sea Fan  

E-Print Network (OSTI)

T Or THE MONTEREV DEEP SEA FAN PLAlE Conpl1.d and ren1our.dO F THE MONTEREY DEEP- SEA FAN by P a t Wilde Berkeley,of segmented alluvial fans in w e s t e r n F r e s n o

Wilde, Pat

1965-01-01T23:59:59.000Z

185

Introduction of a Cooling Fan Efficiency Index  

E-Print Network (OSTI)

Refrigerating and Air-Conditioning Engineers, Inc. (Refrigerating and Air-Conditioning Engineers, Inc. (Refrigerating and Air-Conditioning Engineers, Inc. (

Schiavon, Stefano; Melikov, Arsen

2009-01-01T23:59:59.000Z

186

Data Linking with Ontology Alignment Zhengjie Fan  

E-Print Network (OSTI)

Data Linking with Ontology Alignment Zhengjie Fan INRIA & LIG 655, avenue de l'Europe, Montbonnot data on the web, so that users can share information semantically. Then, linking isolated data sets to to be compared, so that it enhances the accuracy of the linking process. I propose a data linking method

187

Lattice congruences, fans and Hopf algebras  

Science Conference Proceedings (OSTI)

We give a unified explanation of the geometric and algebraic properties of two well-known maps, one from permutations to triangulations, and another from permutations to subsets. Furthermore we give a broad generalization of the maps. Specifically for ... Keywords: Malvenuto-Reutenauer Hopf algebra, coexter group, fan poset, hyperplane arrangement, pattern avoidance, permutohedron, poset of regions, weak order

Nathan Reading

2005-05-01T23:59:59.000Z

188

Economizer Applications in Dual-Duct Air-Handling Units  

E-Print Network (OSTI)

This paper provides analytical tools and engineering methods to evaluate the feasibility of the economizer for dual-duct air-handling units. The results show that the economizer decreases cooling energy consumption without heating energy penalties for dual-fan, dual-duct air-handling units. The economizer has significant heating energy penalties for single-fan, dual-duct air-handling units. The penalties are higher than the cooling energy savings when the cold airflow is less than the hot airflow. Detailed engineering analyses are required to evaluate the feasibility of the economizer for single-fan, dual-duct systems.

Joo, I.; Liu, M.

2002-01-01T23:59:59.000Z

189

Forced air fireplace furnace  

Science Conference Proceedings (OSTI)

The design of heating system for buildings including a fireplace with an open front hearth for burning firewood, a chimney extending from the upper portion of the hearth, a metal firebox being open in the front and closed on the sides and back, a plenum chamber within and surrounding the sides and back of the metal firebox and the chimney lower portion, a horizontal heat distribution chamber positioned in the building attic and communicating at one end with the plenum chamber is described. An air distribution duct connects to the other end of the air distributing chamber, the duct extending to discharge heated air to a place in the building remote from the fireplace. A fan is placed in the horizontal air distributing chamber, and a return air duct extends from selected place in the building and communicates with the plenum chamber lower portion so that the fan draws air through the return air duct, through the plenum chamber around the firebox where the air is heated, through the horizontal distribution chamber, and out through the distribution duct for circulation of the heated air within the building.

Bruce, R.W.; Gorman, R.E.

1980-10-28T23:59:59.000Z

190

Design, testing and two-dimensional flow modeling of a multiple-disk fan  

Science Conference Proceedings (OSTI)

A multiple-disk Tesla type fan has been designed, tested and analyzed two-dimensionally using the conservation of angular momentum principle. Experimental results showed that such multiple-disk fans exhibited exceptionally low performance characteristics, which could be attributed to the low viscosity, tangential nature of the flow, and large mechanical energy losses at both suction and discharge sections that are comparable to the total input power. By means of theoretical analysis, local and overall shearing stresses on the disk surfaces have been determined based on tangential and radial velocity distributions of the air flow of different volume flow rates at prescribed disk spaces and rotational speeds. Then the total power transmitted by rotating disks to air flow, and the power acquired by the air flow in the gap due to transfer of angular momentum have been obtained by numerically integrating shearing stresses over the disk surfaces. Using the measured shaft and hydraulic powers, these quantities were utilized to evaluate mechanical energy losses associated with the suction and discharge sections of the fan. (author)

Engin, Tahsin; Oezdemir, Mustafa; Cesmeci, Sevki [Department of Mechanical Engineering, The University of Sakarya, Esentepe Campus, 54187 Sakarya (Turkey)

2009-11-15T23:59:59.000Z

191

Improving air handler efficiency in houses  

SciTech Connect

Although furnaces, air conditioners and heat pumps have become significantly more efficient over the last couple of decades, residential air handlers have typical efficiencies of only 10% to 15% due to poor electric motor performance and aerodynamically poor fans and fan housings. Substantial increases in performance could be obtained through improved air handler design and construction. A prototype residential air handler intended to address these issues has recently been developed. The prototype and a standard production fan were tested in a full-scale duct system and test chamber at LBNL specifically designed for testing heating, ventilation, and air conditioning systems. The laboratory tests compared efficiency, total airflow, sensitivity to duct system flow resistance, and the effects of installation in a smaller cabinet. The test results showed that the prototype air handler had about twice the efficiency of the standard air handler (averaged over a wide range of operating conditions) and was less sensitive to duct system flow resistance changes. The performance of both air handlers was significantly reduced by reducing the clearance between the air handler and cabinet it was placed in. These test results showed that in addition to the large scope for performance improvement, air handler fans need to be tested in the cabinets they operate in.

Walker, Iain S.

2004-05-01T23:59:59.000Z

192

Analysing International Sports Fan Motivations and Constraints: The Case of Japanese International Sports Fan Tourists and Rugby World Cup Fan Tourists.  

E-Print Network (OSTI)

??The scale of professional sports leagues and mega sports events has expanded recently. Many sports fans travel to foreign countries to watch international events featuring (more)

Nishio, Tatsuru

2013-01-01T23:59:59.000Z

193

Radiative Heating Errors in Naturally Ventilated Air Temperature Measurements Made from Buoys*  

Science Conference Proceedings (OSTI)

Solar radiative heating errors in buoy-mounted, naturally ventilated air temperature sensors are examined. Data from sensors with multiplate radiation shields and collocated, fan-aspirated air temperature sensors from three buoy deployments ...

Steven P. Anderson; Mark F. Baumgartner

1998-02-01T23:59:59.000Z

194

Determining Critical Pressure and Duct Leakage in VAV Air-Handling...  

NLE Websites -- All DOE Office Websites (Extended Search)

for moving air in buildings use a significant amount of energy. It is well known that fan energy use in variable-air-volume (VAV) systems can be reduced by resetting the supply...

195

Public Reading Room  

Office of Legacy Management (LM)

has established a Public Reading Room at 955 has established a Public Reading Room at 955 Mound Road, Miamisburg, Ohio, which contains documents and information related to Mound as required under Section 117(d) of SARA. Copies of key Mound records, including the CERCLA Administrative Record and Information Repository, are kept in the Public Reading Room. The Administrative Record and Information Repository for Mound are updated as new documents are created and an index of documents in the complete collections accompanies each update. The Public Reading Room also contains reference items consisting of technical documents, news clippings, videotapes, journal articles, annual reports, and environmental restoration and decontamination and decommissioning decisional documents. Stakeholders are

196

Sorption of organic gases in residential rooms  

NLE Websites -- All DOE Office Websites (Extended Search)

residential rooms residential rooms Title Sorption of organic gases in residential rooms Publication Type Journal Article LBNL Report Number LBNL-59303 Year of Publication 2007 Authors Singer, Brett C., Alfred T. Hodgson, Toshifumi Hotchi, Katherine Y. Ming, Richard G. Sextro, Emily E. Wood, and Nancy J. Brown Journal Atmospheric Environment Volume 41 Start Page Chapter Pagination 3251-3265 Keywords adsorption, hazardous air pollutants, nerve agents, sink effect, volatile organic compounds Abstract Experiments were conducted to characterize organic gas sorption in residential rooms studied ''as-is'' with furnishings and material surfaces unaltered and in a furnished chamber designed to simulate a residential room. Results are presented for 10 rooms (five bedrooms, two bathrooms, a home office, and two multi-function spaces) and the chamber. Exposed materials were characterized and areas quantified. A mixture of volatile organic compounds (VOCs) was rapidly volatilized within each room as it was closed and sealed for a 5-h Adsorb phase; this was followed by 30-min Flush and 2-h closed-room Desorb phases. Included were alkane, aromatic, and oxygenated VOCs representing a range of ambient and indoor air pollutants. Three organophosphorus compounds served as surrogates for Sarin-like nerve agents. Measured gas-phase concentrations were fit to three variations of a mathematical model that considers sorption occurring at a surface sink and potentially a second, embedded sink. The 3-parameter sink-diffusion model provided acceptable fits for most compounds and the 4-parameter two-sink model provided acceptable fits for the others. Initial adsorption rates and sorptive partitioning increased with decreasing vapor pressure for the alkanes, aromatics and oxygenated VOCs. Best-fit sorption parameters obtained from experimental data from the chamber produced best-fit sorption parameters similar to those obtained from the residential rooms

197

Nonlinear fan instability of electromagnetic waves  

Science Conference Proceedings (OSTI)

This paper studies the linear and nonlinear stages of the fan instability, considering electromagnetic waves of the whistler frequency range interacting resonantly with energetic electron fluxes in magnetized plasmas. The main attention is paid to determine the wave-particle interaction processes that can lead to the excitation of intense electromagnetic waves by nonequilibrium particle distributions involving suprathermal tails, and to explain under what conditions and through what mechanisms they can occur, develop, and saturate. This paper presents and discusses two main processes: (i) the linear fan instability and (ii) the nonlinear process of dynamical resonance merging, which can significantly amplify the energy carried by linearly destabilized waves after they saturate due to particle trapping. This study consists of (i) determining analytically and numerically, for parameters typical of space and laboratory plasmas, the linear growth rates of whistlers excited by suprathermal particle fluxes through the fan instability, as well as the corresponding thresholds and the physical conditions at which the instability can appear, (ii) building a theoretical self-consistent 3D model and a related numerical code for describing the nonlinear evolution of the wave-particle system, and (iii) performing numerical simulations to reveal and characterize the nonlinear amplification process at work, its conditions of development, and its consequences, notably in terms of electromagnetic wave radiation. The simulations show that when the waves have reached sufficient energy levels owing to the linear fan instability, they saturate by trapping particles and due to the complex dynamics of these particles in the electromagnetic fields, the resonant velocities' domains of the waves overlap and merge, meanwhile a strong increase of the wave energy occurs.

Krafft, C. [Laboratoire de Physique des Plasmas, Ecole Polytechnique, 91128 Palaiseau Cedex (France) and University Paris Sud, 91405 Orsay Cedex (France); Volokitin, A. [Space Research Institute (IKI), 117997, 84/32 Profsoyuznaya Str., Moscow (Russian Federation)

2010-10-15T23:59:59.000Z

198

Use of fan rig data for the understanding and prediction of fan broadband noise and noise changes due to a variable area nozzle.  

E-Print Network (OSTI)

??This thesis presents the results of the research component of this EngD, entitled Use of fan rig data for the understanding and prediction of fan (more)

Deane, Eugene Pio

2009-01-01T23:59:59.000Z

199

Demolishing Searle's Chinese Room  

E-Print Network (OSTI)

Searle's Chinese Room argument is refuted by showing that he has actually given two different versions of the room, which fail for different reasons. Hence, Searle does not achieve his stated goal of showing ``that a system could have input and output capabilities that duplicated those of a native Chinese speaker and still not understand Chinese''.

Wolfram Schmied

2004-03-08T23:59:59.000Z

200

An Aerodynamic Design Technique For Optimizing Fan Blade Spacing  

E-Print Network (OSTI)

INTRODUCTION Aerodynamic shape optimization involves designing the most efficient shapes of bodies that move through fluids. An optimization algorithm perturbs the shape of an airfoil until it finds the shape which best exhibits a given design objective. For an inverse design technique, this objective is a prescribed aerodynamic distribution, usually the surface pressure distribution. Liebeck pressure distributions [1], for example, have been demonstrated to generate airfoils with high lift to drag ratios. When designing fans, consideration must be given not only to the shape of the fan blades, but also to the distance separating the fan blades. This spacing is defined by the pitch/chord ratio t/l, where the pitch, t, is the distance between fan blades, and the chord, l, is the length of each fan blade. In this work, an inverse algorithm is developed, then used to design fan blade shapes and to find the optimal blade spacing.

T. Rogalsky; R.W. Derksen; Rt N; Rt N; S. Kocabiyik

1999-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Effect of baselevel change on floodplain and fan sediment storage and ephemeral tributary channel morphology, Navarro River, California  

E-Print Network (OSTI)

CHANGE ON FLOODPLAIN AND FAN SEDIMENT STORAGE AND EPHEMERALaffects floodplain and fan sediment storage and smalllowered baselevel on floodplain and fan sediment storage and

Florsheim, Joan L; Mount, Jeffrey F.; Rutten, Luke T.

2000-01-01T23:59:59.000Z

202

Stratigraphic evolution and characteristics of lobes : a high-resolution study of Fan 3, Tanqua Karoo, South Africa.  

E-Print Network (OSTI)

??Fan 3 is one of four basin-floor fans that form part of the Tanqua Karoo Fan Complex in South Africa. It can be subdivided into (more)

Neethling, J. M.

2009-01-01T23:59:59.000Z

203

Active control of fan noise and vortex shedding.  

E-Print Network (OSTI)

??[Truncated abstract] The subject of fan noise generating mechanisms and its control has been studied intensively over the past few decades as a result of (more)

Wong, Yee-Jun

2004-01-01T23:59:59.000Z

204

Optimization of Active Noise Control for Small Axial Cooling Fans.  

E-Print Network (OSTI)

??Previous work has shown that active noise control is a feasible solution to attenuate tonal noise radiated by small axial cooling fans, such as those (more)

Monson, Brian B 1979-

2006-01-01T23:59:59.000Z

205

Characteristics of Residential Housing Units by Ceiling Fans, 2001  

U.S. Energy Information Administration (EIA)

A reporting of the number of housing units using ceiling fans in U.S. households as reported in the 2001 Residential Energy Consumption Survey

206

Water-side Economizer for Non-Fan Cooling Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

changes to the commercial provisions of the 2012 IECC: Water-side Economizer for Non-Fan Cooling Systems R Hart Pacific Northwest National Laboratory January 2013 Proposal...

207

Table 1. Household Characteristics by Ceiling Fans, 2001  

U.S. Energy Information Administration (EIA)

A reporting of the number of housing units using ceiling fans in U.S. households as reported in the 2001 Residential Energy Consumption Survey

208

Improving air handler efficiency in residential HVAC applications  

SciTech Connect

In continuing the development of energy efficiency standards, consideration has turned to air handlers used for heating and air conditioning of consumer residences. These air handlers have typical efficiencies of about 10% to 15% due to poor electric motor performance and aerodynamically poor fans and fan housings. This study was undertaken to examine some of these performance issues, under carefully controlled laboratory conditions, to support potential regulatory changes. In addition, this study examined the performance of a prototype air handler fan assembly that offers the potential for substantial increases in performance. This prototype and a standard production fan were tested in a full-scale duct system and test chamber at LBNL which was specifically designed for testing heating, ventilation, and air conditioning systems. The laboratory tests compared efficiency, total airflow, sensitivity to duct system flow resistance, and the effects of installation in a smaller cabinet. The test results showed that, averaged over a wide range of operating conditions, the prototype air handler had about twice the efficiency of the standard air handler and was less sensitive to duct system flow resistance changes. The performance of both air handlers was significantly reduced by reducing the space between the air handler and the cabinet it was installed in. Therefore any fan rating needs to be performed using the actual cabinet it will be used in.

Walker, Iain S.; Mingee, Michael D.; Brenner, Douglas E.

2003-08-01T23:59:59.000Z

209

SRNL - News Room  

NLE Websites -- All DOE Office Websites (Extended Search)

& Development Projects in the "Press Room" at www.doe.gov for further details.) Expected funding for the SRNL project is estimated at approximately one-half million dollars a year...

210

Cooling Tower Fan Motor Power Optimization Study  

Science Conference Proceedings (OSTI)

Cooling towers are in use at more than 200 major electric generating plants in the United States, representing approximately 800 units and a total of more than 210,000 MW. The auxiliary power consumed by cooling tower fan motors can significantly reduce the net power output of steam-cycle power plants. Cooling tower specifications are established by the economic and operational requirements of maximum unit load and the most demanding environmental conditions expected in the towers locale. Since power pl...

2011-11-16T23:59:59.000Z

211

Standard Methods of Characterizing Performance of Fan Filter Units, Version 3.0  

E-Print Network (OSTI)

power input to operate the FFU at certain airflow conditions, including fan motor, controller, and transformerpower supply to the fan motor, speed control and display device, transformer,power demand shall include fan motor, speed control and display device, transformer,

Xu, Tengfang

2007-01-01T23:59:59.000Z

212

An Innovative Method for Dynamic Characterization of Fan Filter Unit Operation.  

E-Print Network (OSTI)

power for fan motor, controller, and accessories such as transformerpower demand shall include fan motor, speed control and display device, transformer,power demand shall include the fan, frequency drive motor, speed control device, transformer

Xu, Tengfang

2006-01-01T23:59:59.000Z

213

Development of a Fan-Filter Unit Test Standard, Laboratory Validations, and its Applications across Industries  

E-Print Network (OSTI)

Energy Performance of Fan-Filter Units, Version 1.3 (2005).Energy Performance of Fan-Filter Units, Version 2.0 (2006).Evaluation of Fan-filter Units Aerodynamic and Energy

Xu, Tengfang

2008-01-01T23:59:59.000Z

214

Development of a Fan-Filter Unit Test Standard, Laboratory Validations, and its Applications across Industries  

E-Print Network (OSTI)

Energy Performance of Fan-Filter Units, Version 1.3 (2005).Energy Performance of Fan-Filter Units, Version 2.0 (2006).Laboratory Evaluation of Fan-filter Units Aerodynamic and

Xu, Tengfang

2008-01-01T23:59:59.000Z

215

Standard Methods of Characterizing Performance of Fan Filter Units, Version 3.0  

E-Print Network (OSTI)

Efficient Filtration: Fan-filter Units. Final Report,Xu. 2007. The Development of Fan Filter Unit with Flow Rate2007. Performance of Large Fan Filter Units for Cleanroom

Xu, Tengfang

2007-01-01T23:59:59.000Z

216

Starring Madhuri as Durga: The Madhuri Dixit Temple and Performative Fan-Bhakti of Pappu Sardar  

E-Print Network (OSTI)

Devotion and Defiance in Fan Activity. In Ravi Vasudevan,Temple and Performative Fan-Bhakti of Pappu Sardar / 415Temple and Performative Fan-Bhakti of Pappu Sardar Shalini

Kakar, Shalini

2009-01-01T23:59:59.000Z

217

Control system for heat exchangers fans in a refrigeration system  

Science Conference Proceedings (OSTI)

The paper presents a method for controlling evaporator and condenser fans in a refrigeration system. The refrigeration system includes a refrigerant circuit defined by a compressor, a condenser, a throttling device, and an evaporator. The system includes ... Keywords: controlling, fan, refrigeration system, variable frequency drive unit

Cristian Iosifescu; Valeriu Damian; C?lin Ciufudean

2010-05-01T23:59:59.000Z

218

Fan Foundation Systems--Analysis and Design Guidelines  

Science Conference Proceedings (OSTI)

Dynamic analysis is the most effective tool for determining the root causes of excessive fan vibration. This study demonstrated the importance of using such analysis in conjunction with a "total systems" approach that considers how the properties of all major fan system components, including foundation, piles, and soil conditions, contribute to vibration.

1986-08-19T23:59:59.000Z

219

DOE Solar Decathlon: Press Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Bios Press Releases Photos Videos Education Sponsors Volunteers History FAQs Contacts Solar Decathlon Press Room The U.S. Department of Energy Solar Decathlon press room provides...

220

Feedback Applications in Active Noise Control for Small Axial Cooling Fans.  

E-Print Network (OSTI)

??Feedback active noise control (ANC) has been applied as a means of attenuating broadband noise from a small axial cooling fan. Such fans are used (more)

Green, Matthew J 1978-

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Aerodynamic Experiments on a Ducted Fan in Hover and Edgewise Flight.  

E-Print Network (OSTI)

??Ducted fans and ducted rotors have been integrated into a wide range of aerospace vehicles, including manned and unmanned systems. Ducted fans offer many potential (more)

Myers, Leighton

2009-01-01T23:59:59.000Z

222

Exact solutions to combinatorial optimizations and the traveling baseball fan problem.  

E-Print Network (OSTI)

?? The traveling baseball fan problem is an extension of the classic traveling salesman problem, in which a sports fan wishes to travel to the (more)

Terrell, Neal D.

2013-01-01T23:59:59.000Z

223

Il fenomeno dei fan nel mercato della musica. Analisi netnografica dei seguaci italiani di Bruce Springsteen.  

E-Print Network (OSTI)

??Lo studio ha ad oggetto la comunit dei fan italiani di Bruce Springsteen. Dopo aver analizzato la letteratura e descritto il fenomeno dei fan e (more)

Gallo, Sara

2007-01-01T23:59:59.000Z

224

Costs and benefits of energy efficiency improvements in ceiling fans  

SciTech Connect

Ceiling fans contribute significantly to residential electricity consumption, especially in developing countries with warm climates. The paper provides analysis of costs and benefits of several options to improve the efficiency of ceiling fans to assess the global potential for electricity savings and green house gas (GHG) emission reductions. Ceiling fan efficiency can be cost-effectively improved by at least 50% using commercially available technology. If these efficiency improvements are implemented in all ceiling fans sold by 2020, 70 terawatt hours per year could be saved and 25 million metric tons of carbon dioxide equivalent (CO2-e) emissions per year could be avoided, globally. We assess how policies and programs such as standards, labels, and financial incentives can be used to accelerate the adoption of efficient ceiling fans in order to realize potential savings.

Shah, Nihar; Sathaye, Nakul; Phadke, Amol; Letschert, Virginie [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division] [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technology Division

2013-10-15T23:59:59.000Z

225

Method for fabricating fan-fold shielded electrical leads  

DOE Patents (OSTI)

Fan-folded electrical leads made from copper cladded Kapton, for example, with the copper cladding on one side serving as a ground plane and the copper cladding on the other side being etched to form the leads. The Kapton is fan folded with the leads located at the bottom of the fan-folds. Electrical connections are made by partially opening the folds of the fan and soldering, for example, the connections directly to the ground plane and/or the lead. The fan folded arrangement produces a number of advantages, such as electrically shielding the leads from the environment, is totally non-magnetic, and has a very low thermal conductivity, while being easy to fabricate.

Rohatgi, Rajeev R. (Mountain View, CA); Cowan, Thomas E. (Livermore, CA)

1994-01-01T23:59:59.000Z

226

Method for fabricating fan-fold shielded electrical leads  

DOE Patents (OSTI)

Fan-folded electrical leads made from copper cladded Kapton, for example, with the copper cladding on one side serving as a ground plane and the copper cladding on the other side being etched to form the leads. The Kapton is fan folded with the leads located at the bottom of the fan-folds. Electrical connections are made by partially opening the folds of the fan and soldering, for example, the connections directly to the ground plane and/or the lead. The fan folded arrangement produces a number of advantages, such as electrically shielding the leads from the environment, is totally non-magnetic, and has a very low thermal conductivity, while being easy to fabricate. 3 figures.

Rohatgi, R.R.; Cowan, T.E.

1994-12-27T23:59:59.000Z

227

Review: The Dragon & The Elephant: Agricultural and Rural Reforms in China and India edited by Ashok Gulati and Shenggen Fan  

E-Print Network (OSTI)

Ashok Gulati and Shenggen Fan (Eds. ) Reviewed by VarinderIndia Gulati, Ashok and Fan, Shenggen (Eds. ). The Dragon &

Jain, Varinder

2008-01-01T23:59:59.000Z

228

Variable Speed Drive Volumetric Tracking (VSDVT) for Airflow Control in Variable Air Volume (VAV) Systems  

E-Print Network (OSTI)

An airflow control method has been developed for variable air volume (VAV) systems. This airflow control method is named VSD volumetric tracking (VSDVT) since both the supply and return airflows are determined using signals of the variable speed drives (VSD) instead of the flow stations. Its performance is studied and compared with the fan tracking (FT) method using model simulations. The VSDVT maintains a constant building pressure and the required outside airflow under all load conditions, reduces the annual return air fan energy by up to 50%, and the annual supply air fan energy by up to 30%. This paper presents the VSDVT method, the system models, and the simulation results.

Liu, M.

2002-01-01T23:59:59.000Z

229

The Fan Observatory Bench Optical Spectrograph (FOBOS)  

E-Print Network (OSTI)

The Fan Observatory Bench Optical Spectrograph (FOBOS) is intended for single-object optical spectroscopy at moderate resolution (R~1500-3000) using a fiber-fed, bench-mounted design to maintain stability. Whenever possible, the instrument uses off-the-shelf components to maintain a modest cost. FOBOS supports Galactic astronomy projects that require consistently well-measured (~5 km/sec) radial velocities for large numbers of broadly distributed and relatively bright (Vdesign was optimized for use in the range 470-670 nm. Test data indicate that the instrument is stable and capable of measuring radial velocities with precision better than 3 km/sec at a resolution of R~1500 with minimal calibration overhead.

Jeffrey D. Crane; Steven R. Majewski; Richard J. Patterson; Michael F. Skrutskie; Elena Y. Adams; Peter M. Frinchaboy

2005-02-23T23:59:59.000Z

230

Submitting Organization Hongyou Fan Sandia National Laboratories  

NLE Websites -- All DOE Office Websites (Extended Search)

 2007 R&D 100 Award Entry Form  Submitting Organization Hongyou Fan Sandia National Laboratories Advanced Materials Laboratory 1001 University Boulevard SE Albuquerque, NM 87106, USA 505-272-7128 (phone) 505-272-7336 (fax) hfan@sandia.gov AFFIRMATION: I affirm that all information submitted as a part of, or supplemental to, this entry is a fair and accurate represen- tation of this product. Submitter's signature_______________________________ Earl Stromberg Lockheed Martin Aeronautics Mail Zone 2893 PO Box 748 Fort Worth, TX 76101, USA 817-763-7376 (phone) 817-762-6911 (fax) Earl.W.Stromberg@lmco.com Self-Assembling Process for Fabricating Tailored Thin Films This simple, economical nanotechnology coating process enables the development of nanoparticle thin films

231

Particle trajectories and acceleration during 3D fan reconnection  

E-Print Network (OSTI)

Context. The primary energy release in solar flares is almost certainly due to magnetic reconnection, making this a strong candidate as a mechanism for particle acceleration. While particle acceleration in 2D geometries has been widely studied, investigations in 3D are a recent development. Two main classes of reconnection regimes at a 3D magnetic null point have been identified: fan and spine reconnection Aims. Here we investigate particle trajectories and acceleration during reconnection at a 3D null point, using a test particle numerical code, and compare the efficiency of the fan and spine regimes in generating an energetic particle population. Methods. We calculated the time evolution of the energy spectra. We discuss the geometry of particle escape from the two configurations and characterise the trapped and escaped populations. Results. We find that fan reconnection is less efficent than spine reconnection in providing seed particles to the region of strong electric field where acceleration is possible. The establishment of a steady-state spectrum requires approximately double the time in fan reconnection. The steady-state energy spectrum at intermediate energies (protons 1 keV to 0.1 MeV) is comparable in the fan and spine regimes. While in spine reconnection particle escape takes place in two symmetric jets along the spine, in fan reconnection no jets are produced and particles escape in the fan plane, in a ribbon-like structure.

S. Dalla; P. K. Browning

2008-11-07T23:59:59.000Z

232

Electronic Reading Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Electronic Reading Room - making information about the Freedom of Information Act (FOIA) and Privacy Act process accessible to the public electronically. Electronic Reading Room - making information about the Freedom of Information Act (FOIA) and Privacy Act process accessible to the public electronically. Major Information Systems - Final Opinions - [5 USC 552 (a)(2)](A) final opinions, including concurring and dissenting opinions, as well as orders, made in the adjudication of cases within the Office of Hearings and Appeals Statements of Policy and Interpretation and Administrative Staff Manuals and Instructions - [5 USC 552 (a)(2)](B) those statements of policy and interpretation which have been adopted by the agency and are not published in the Federal Register - Directives, DOE Orders, Headquarters Orders, Secretarial Notices, Technical Standards, Forms, Delegations, Electronic Library Public Reading Facilities - making information available for public inspection and copying

233

Reading Room Locations  

NLE Websites -- All DOE Office Websites (Extended Search)

FOIA Offices and Reading Rooms FOIA Offices and Reading Rooms FOIA Office Locations Our FOIA Officers are located at various sites throughout the DOE complex, each with responsibility for records located at or under the jurisdiction of the site. We recommend that you send your request directly to that specific site. This will shorten the processing time. However, if you do not know which location has responsive records, you may either call the Headquarters FOIA office at (202) 586-5955 to determine the appropriate office, or mail the request to the Headquarters FOIA office. Other records are publicly available in the facilities listed below: Headquarters U.S. Department of Energy FOIA/Privacy Act Group 1000 Independence Avenue, SW Washington, D.C. 20585 Phone: 202-586-5955 Fax: 202-586-0575

234

Moving air for comfort  

E-Print Network (OSTI)

to facilitate the design layout of fans in accordance withCeiling fans in open office space Figure 7 Design office inapproximately 30-70 W/fan. In the design, they were assumed

Arens, Edward; Turner, Stephen; Zhang, Hui; Paliaga, Gwelen

2009-01-01T23:59:59.000Z

235

Valance heating/cooling system attains largest application in 1,000-room hotel  

SciTech Connect

Room temperatures in the 1,000 guest rooms of Chicago's Hyatt Regency Hotel are controlled by a valance heating and cooling system that functions by means of radiation and convection. The valances are mounted below the ceiling and consists of finned tubes and a drain tube contained within a wall-mounted enclosure. The finned tubes and drain are connected to a riser system, that is connected to a hot and cold water supply. The economics of the system is discussed and with no fans, motors, or blowers to run, energy is conserved. (MCW)

1976-08-01T23:59:59.000Z

236

Searching optimal shapes for blades of a fan  

E-Print Network (OSTI)

A nonlinear differential equation about optimal shapes for blades of a fan. A boundary value differential problem from engineering, geometrical or physical bonds. A relation between linear profiles and constant speed along the side under flow.

Gianluca Argentini

2008-03-26T23:59:59.000Z

237

Sinewave parameter estimation using the fast fan-chirp transform  

E-Print Network (OSTI)

Sinewave analysis/synthesis has long been an important tool for audio analysis, modification and synthesis. The recently introduced fan-chirp Transform (FChT) [2,3] has been shown to improve the fidelity of sinewave parameter ...

Dunn, Robert B.

238

Developing a Standard Test Method for Characterizing Fan-filter...  

NLE Websites -- All DOE Office Websites (Extended Search)

Developing a Standard Test Method for Characterizing Fan-filter Units Used in Industries Speaker(s): Tim Xu Date: July 21, 2008 - 12:00pm Location: 90-3122 Seminar HostPoint of...

239

Use of VFDs on Asphalt Plant Induced Draft Fans  

E-Print Network (OSTI)

Studies of 10 asphalt plants in the Intermountain Region have identified average ID fan energy savings of 68% by controlling airflow using Variable Frequency Drives (VFDs) on the fan motors in place of damper control (inlet or outlet). Average paybacks were 3-5 years before utility incentives. In the 10 plants evaluated, the ID fans accounted for as much as 30% of the total plant electrical consumption. In the majority of these plants the outlet dampers were typically 50%-60% closed. Fan motors ranged from 200 Hp to 500 Hp. With approximately 3,600 existing asphalt plants in operation across the United States, a large opportunity for retrofits exists. Working with manufacturers and owners, a new standard can be established for installing VFDs on all plants.

Anderson, G. R.; Case, P. L.; Lowery, J.

2005-01-01T23:59:59.000Z

240

Crossover distributions at the edge of the rarefaction fan  

E-Print Network (OSTI)

We consider the weakly asymmetric limit of simple exclusion process with drift to the left, starting from step Bernoulli initial data with $\\rho_-fan. We study the fluctuations of the process observed along slopes in the fan, which are given by the Hopf--Cole solution of the Kardar-Parisi-Zhang (KPZ) equation, with appropriate initial data. For slopes strictly inside the fan, the initial data is a Dirac delta function and the one point distribution functions have been computed in [Comm. Pure Appl. Math. 64 (2011) 466-537] and [Nuclear Phys. B 834 (2010) 523-542]. At the edge of the rarefaction fan, the initial data is one-sided Brownian. We obtain a new family of crossover distributions giving the exact one-point distributions of this process, which converge, as $T\

Ivan Corwin; Jeremy Quastel

2010-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

A Tip Driven Fan Based on SERAPHIM Technology  

SciTech Connect

SERAPHIM technology appears capable of efficiently driving a tip driven fan. If the motor is powered using an inverter and resonant circuit, the size and weight could be considerably below that of a comparable rotary electric motor.

MARDER, BARRY M.

2002-01-01T23:59:59.000Z

242

Property:Building/SPElectrtyUsePercCirculationFans | Open Energy  

Open Energy Info (EERE)

SPElectrtyUsePercCirculationFans SPElectrtyUsePercCirculationFans Jump to: navigation, search This is a property of type String. Circulation fans Pages using the property "Building/SPElectrtyUsePercCirculationFans" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 18.6715328229 + Sweden Building 05K0002 + 0.0 + Sweden Building 05K0003 + 3.84924044288 + Sweden Building 05K0004 + 13.5679722118 + Sweden Building 05K0005 + 10.115947775 + Sweden Building 05K0006 + 10.4348038368 + Sweden Building 05K0007 + 3.09034005771 + Sweden Building 05K0008 + 1.5024342653 + Sweden Building 05K0009 + 13.4365662073 + Sweden Building 05K0010 + 0.0 + Sweden Building 05K0011 + 2.75323793817 + Sweden Building 05K0012 + 15.8993705073 + Sweden Building 05K0013 + 1.11354848212 +

243

Property:Building/SPElectrtyUsePercFans | Open Energy Information  

Open Energy Info (EERE)

SPElectrtyUsePercFans SPElectrtyUsePercFans Jump to: navigation, search This is a property of type String. Fans Pages using the property "Building/SPElectrtyUsePercFans" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 7.29539104961 + Sweden Building 05K0002 + 16.7673965927 + Sweden Building 05K0003 + 27.9131959869 + Sweden Building 05K0004 + 12.2479817873 + Sweden Building 05K0005 + 29.1925346224 + Sweden Building 05K0006 + 15.8653423601 + Sweden Building 05K0007 + 12.809449974 + Sweden Building 05K0008 + 22.2979541594 + Sweden Building 05K0009 + 22.7088540206 + Sweden Building 05K0010 + 13.3738132017 + Sweden Building 05K0011 + 25.1040933765 + Sweden Building 05K0012 + 22.6542018423 + Sweden Building 05K0013 + 24.3166483485 +

244

Designing Axial Flow Fan for Flow and Noise  

E-Print Network (OSTI)

A comprehensive finite element methodology is developed to predict the compressible flow performance of a non-symmetric 7-blade axial flow fan, and to quantify the source strength and sound pressure levels at any location in the system. The acoustic and flow performances of the fan are predicted simultaneously using a computational aero-acoustic technique combining transient flow analysis and noise propagation. The calculated sound power levels compare favorably with the measured sound power data per AMCA 300-96 code.

Subrata Roy; Phillip Cho; Fred Pri; International Off-highway

1999-01-01T23:59:59.000Z

245

Common Air Conditioner Problems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

246

Common Air Conditioner Problems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

247

Record of Communication Concerning Ceiling Fan and Ceiling Fan Light Kit Framework DocumentDocket No. EERE-2012-BT-STD-0045  

Energy.gov (U.S. Department of Energy (DOE))

This memo provides an overview of communications made to DOE staff on the subject of possible changes to standards and test procedures for ceiling fans and ceiling fan light kits.

248

Introduction of a Cooling Fan Efficiency Index  

E-Print Network (OSTI)

of the cooling effect measured with the thermal manikin andThe mea- sured cooling effect with the thermal manikin isby a thermal manikin to quantify the cooling effects of air

Schiavon, Stefano; Melikov, Arsen

2009-01-01T23:59:59.000Z

249

Tertiary Containment in a Multi-Room Tritium Facility  

SciTech Connect

An experimental system to provide tertiary containment at Mound has been upgraded to support a new multi-room tritium handling facility. This system is used to remove tritium from room air in the event of primary (process) and secondary (glovebox) containment failure. The upgraded system includes a faster response time, piping and valves that are more leaktight, and a new control panel that better indicates the system status and operating conditions.

Kent, L. R.

1985-04-01T23:59:59.000Z

250

Performance Optimization of a Fan System- Overcoming Impacts of Modified Design Criteria Due to Regulatory Requirements and Changed Operating Conditions  

E-Print Network (OSTI)

The Louisiana Pacific mill in Tomahawk Wisconsin manufactures oriented-strand board. Several large induced-draft fans and combustion-air blowers were operating inefficiently at this mill. This case study highlights a systems approach that was applied to address fan inefficiency. Energy savings from optimizing the system are estimated to be 338 kW, nearly half of the original measured input power of 678 kW. The project is currently being implemented and will have a payback period of less than 8 months. The opportunities here are typical of opportunities thought to exist in most industrial plants. In this case, process needs changed due to environmental regulations and change of location, but the system did not, leading to low overall system efficiency.

Wroblewski, R. G.; Preis, F.; Smith, R.

1997-04-01T23:59:59.000Z

251

Modelling the architecture of distal sand-rich lobe deposits : an example from Fan 2, Skoorsteenberg Formation, Tanqua Karoo, South Africa.  

E-Print Network (OSTI)

??Fan 2, one of five submarine fan systems of the Tanqua fan complex in the south-western Karoo Basin, South Africa, is subdivided into Lower, Middle (more)

Steyn, Rochelle

2009-01-01T23:59:59.000Z

252

Air-Source Heat Pump Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Source Heat Pump Basics Air-Source Heat Pump Basics Air-Source Heat Pump Basics August 19, 2013 - 11:03am Addthis Air-source heat pumps transfer heat between the inside of a building and the outside air. How Air-Source Heat Pumps Work This diagram of a split-system heat pump heating cycle shows refrigerant circulating through a closed loop that passes through the wall of a house. Inside the house the refrigerant winds through indoor coils, with a fan blowing across them, and outside the house is another fan and another set of coils, the outdoor coils. A compressor is between the coils on one half of the loop, and an expansion valve is between the coils on the other half. The diagram is explained in the caption. In heating mode, an air-source heat pump evaporates a refrigerant in the outdoor coil; as the liquid evaporates it pulls

253

Media Room | National Nuclear Security Administration  

NLE Websites -- All DOE Office Websites (Extended Search)

Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog The National Nuclear Security Administration Media Room Home > Media Room Media Room NNSA's Office of...

254

Photo of the Week: Fan-tastic | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fan-tastic Fan-tastic Photo of the Week: Fan-tastic August 17, 2012 - 10:30am Addthis In Jonesboro, Arkansas, a Nordex USA employee stands between utility-scale components that will eventually make up a completed wind turbine. Under the Recovery Act, Nordex USA received a tax credit to assist in the creation of the Jonesboro manufacturing facility, which opened in October 2010. | Photo courtesy of Nordex USA. In Jonesboro, Arkansas, a Nordex USA employee stands between utility-scale components that will eventually make up a completed wind turbine. Under the Recovery Act, Nordex USA received a tax credit to assist in the creation of the Jonesboro manufacturing facility, which opened in October 2010. | Photo courtesy of Nordex USA. Sarah Gerrity Sarah Gerrity Multimedia Editor, Office of Public Affairs

255

Field testing of component-level model-based fault detection methods for mixing boxes and VAV fan systems  

E-Print Network (OSTI)

precluded testing the fan based on design data. Since thisStatic Pressure (inWg) fan CFM SF-SP SF-SP-Design-Sim time (supply fan pressure rise) SF- DP SF-DP-Design-simulated D.

Xu, Peng; Haves, Philip

2002-01-01T23:59:59.000Z

256

Field testing of component-level model-based fault detection methods for mixing boxes and VAV fan systems  

E-Print Network (OSTI)

measurement of airflow rate. Supply fan speed (0-1) SA S.A.Supply Fan test S.B.Fan pressure rise calibration SF-DP-Simulated Pressure

Xu, Peng; Haves, Philip

2002-01-01T23:59:59.000Z

257

Blue fan palm distribution and seed removal patterns in three desert oases of northern Baja California, Mexico  

E-Print Network (OSTI)

DOI 10.1007/s11258-009-9682-4 Blue fan palm distribution anddistribution patterns of the blue fan palm, Brahea armata,i) the levels of blue fan palm seed removal by vertebrates

Wehncke, Elisabet V.; Lpez-Medelln, Xavier; Ezcurra, Exequiel

2010-01-01T23:59:59.000Z

258

Tips: Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Air Conditioners Tips: Air Conditioners Tips: Air Conditioners June 24, 2013 - 6:31pm Addthis Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Buying a bigger room air conditioner won't necessarily make you feel more comfortable during the hot summer months. In fact, a room air conditioner that's too big for the area it is supposed to cool will perform less efficiently and less effectively than a smaller, properly sized unit. The reason: an oversized unit will cool the room(s) to the thermostat set-point before proper dehumidification occurs, making the area feel "clammy"

259

Tips: Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Air Conditioners Tips: Air Conditioners Tips: Air Conditioners June 24, 2013 - 6:31pm Addthis Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Buying a bigger room air conditioner won't necessarily make you feel more comfortable during the hot summer months. In fact, a room air conditioner that's too big for the area it is supposed to cool will perform less efficiently and less effectively than a smaller, properly sized unit. The reason: an oversized unit will cool the room(s) to the thermostat set-point before proper dehumidification occurs, making the area feel "clammy"

260

Income Tax Deduction for Solar-Powered Roof Vents or Fans (Indiana...  

Open Energy Info (EERE)

1232012 References DSIRE1 Summary Indiana allows taxpayers to take a deduction on solar-powered roof fans (or vent, also sometimes called an attic fan) installed in a home...

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Income Tax Deduction for Solar-Powered Roof Vents or Fans  

Energy.gov (U.S. Department of Energy (DOE))

Indiana allows taxpayers to take a deduction on solar-powered roof fans (or vent, also sometimes called an attic fan) installed in a home that the taxpayer owns or leases. The deduction is for 50%...

262

Laugh out loud in real life : women's humor and fan identity  

E-Print Network (OSTI)

The emerging field of fan studies has, until recently, been defined only by the research that has taken place within it. Almost universally, this research focuses on self-identified fans. However, scholars are beginning ...

Klink, Madeline LeNore

2010-01-01T23:59:59.000Z

263

Experimental investigation of a six inch diameter, four inch span cross-flow fan .  

E-Print Network (OSTI)

??Investigations into the use of a cross-flow fan as a potential source of propulsion and lift have arisen due to the cross-flow fan's geometry, light (more)

Ulvin, Jessica M.

2008-01-01T23:59:59.000Z

264

Improve the Energy Efficiency of Fan Systems, Software Tools for Industry, Industrial Technologies Program (ITP) (Fact Sheet)  

Science Conference Proceedings (OSTI)

This fact sheet describes how the Industrial Technologies Program Fan System Assessment Tool (FSAT) can help quantify energy consumption and savings opportunities in industrial fan systems.

Not Available

2008-12-01T23:59:59.000Z

265

Improving air handler efficiency in houses  

E-Print Network (OSTI)

of different blade design and fan to housing clearances forimprovements, such as fan blade and cabinet design are hardequipment design (not putting large fans in small cabinets).

Walker, Iain S.

2004-01-01T23:59:59.000Z

266

China Energy Efficiency Round Robin Testing Results for Room  

E-Print Network (OSTI)

LBNL-3502E China Energy Efficiency Round Robin Testing Results for Room Air Conditioners Nan Zhou Round Robin Testing Results and Analysis by China National Institute of Standardization..................................................................................................................... 1 I.1.1 China's Energy Constraint Problem and the Need to Improve the Energy Efficiency of Energy

267

A satisfiability algorithm for constant depth boolean circuits with unbounded fan-in gates  

E-Print Network (OSTI)

Boolean Circuits with Unbounded Fan-In Gates A dissertationAC 0 by allowing unbounded fan-in M OD m 1 , . . . , M OD mSince each gate in ? has fan-in at most k and ? has depth D

Matthews, William Grant

2011-01-01T23:59:59.000Z

268

Fan Aerodynamic Performance Guarantees: Do Your Policies, Procedures and Penalties Provide Adequate Certainty?  

E-Print Network (OSTI)

With few exceptions, fan vendors do not provide a written guarantee regarding aerodynamic performance. Some fan vendors even go so far as to state in their terms and conditions of sale that fan performance is not guaranteed unless it is specifically reque

Kaufman, S. G.; Martin, V.; Falk, M. A.

2004-01-01T23:59:59.000Z

269

The Forming of AISI 409 sheets for fan blade manufacturing  

SciTech Connect

The necessity of adapting the standardized fan models to conditions of higher temperature has emerged due to the growth of concern referring to the consequences of the gas expelling after the Mont Blanc tunnel accident in Italy and France, where even though, with 100 fans in operation, 41 people died. The objective of this work is to present an alternative to the market standard fans considering a new technology in constructing blades. This new technology introduces the use of the stainless steel AISI 409 due to its good to temperatures of gas exhaust from tunnels in fire situation. The innovation is centered in the process of a deep drawing of metallic sheets in order to keep the ideal aerodynamic superficies for the fan ideal performance. Through the impression of circles on the sheet plane it is shown, experimentally, that, during the pressing process, the more deformed regions on the sheet plane of the blade can not reach the deformation limits of the utilized sheet material.

Foroni, F. D.; Menezes, M. A.; Moreira Filho, L. A. [ITA - Aeronautic Technological Institute, IEM, Praca Mal. Eduardo Gomes, 50 - Vila das Acacias - S. J. Campos, Brasil - CEP 1228-900 (Brazil)

2007-04-07T23:59:59.000Z

270

Air-Source Heat Pump Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Source Heat Pump Basics Source Heat Pump Basics Air-Source Heat Pump Basics August 19, 2013 - 11:03am Addthis Air-source heat pumps transfer heat between the inside of a building and the outside air. How Air-Source Heat Pumps Work This diagram of a split-system heat pump heating cycle shows refrigerant circulating through a closed loop that passes through the wall of a house. Inside the house the refrigerant winds through indoor coils, with a fan blowing across them, and outside the house is another fan and another set of coils, the outdoor coils. A compressor is between the coils on one half of the loop, and an expansion valve is between the coils on the other half. The diagram is explained in the caption. In heating mode, an air-source heat pump evaporates a refrigerant in the outdoor coil; as the liquid evaporates it pulls

271

Efficiency of a liquid desiccant dehumidification system regenerated by using solar collectors/regenerators with photovoltaic fans  

Science Conference Proceedings (OSTI)

A hybrid solar dehumidification air-conditioning system was used to study the absorption of water vapor from moist air by contacting the air with aqueous solutions that contained from 90 to 94% triethylene glycol (TEG). For the packings of 2-inch polypropylene Jaeger Tri-Packs, which have a surface-to-volume ratio of 157 m{sup 2}/m{sup 3} (48 ft{sup 2}/ft{sup 3}), the efficiency of dehumidification can reach 93.3%. The environmental air was introduced into the dehumidifier cocurrently flowing with the liquid desiccant, and the liquid desiccant was sprayed on the top of the packing material. The air-to-liquid mass flow ratio was controlled in a range of 0.46 to 1.36. As the moisture was absorbed from air by the TEG solution, the solution was diluted. The regeneration of the solution was carried out in 20-piece (38.8 m{sup 2}) basin-type solar collectors/regenerators whose regeneration coefficients of performance are above 0.2. Air generated by photovoltaic fans was blown into the solar collectors/regenerators and carried away the water vapor from the evaporation of the aqueous desiccant solution. On the basis of the experimental results, the system performance is acceptable for most applications.

Tsair-Wang Chung; Wei-Yih Wu; Wen-Jih Yan; Ching-Lin Huang [Industrial Technology Research Institute, Taiwan (China)

1995-04-01T23:59:59.000Z

272

Hypercomputation in the Chinese Room  

Science Conference Proceedings (OSTI)

I rehearse a number of objections to John Searle's famous Chinese room argument. One is the 'hypercomputational objection' (Copeland 2002a). Hypercomputation is the computation of functions that cannot be computed in the sense of Turing (1936); the term ...

B. Jack Copeland

2002-10-01T23:59:59.000Z

273

Nuclear reactor control room construction  

DOE Patents (OSTI)

A control room for a nuclear plant is disclosed. In the control room, objects labelled 12, 20, 22, 26, 30 in the drawing are no less than four inches from walls labelled 10.2. A ceiling contains cooling fins that extend downwards toward the floor from metal plates. A concrete slab is poured over the plates. Studs are welded to the plates and are encased in the concrete. 6 figures.

Lamuro, R.C.; Orr, R.

1993-11-16T23:59:59.000Z

274

Development of a Laboratory Verified Single-Duct VAV System Model with Fan Powered Terminal Units Optimized Using Computational Fluid Dynamics  

E-Print Network (OSTI)

Single Duct Variable Air Volume (SDVAV) systems use series and parallel Fan Powered Terminal Units to control the air flow in conditioned spaces. This research developed a laboratory verified model of SDVAV systems that used series and parallel fan terminal units where the fan speeds were controlled by either Silicon Controlled Rectifiers (SCR) or Electronically Commutated Motors (ECM) motors. As part of the research, the model was used to compare the performance of the systems and to predict the harmonics generated by ECM systems. All research objectives were achieved. The CFD model, which was verified with laboratory measurements, showed the potential to identify opportunities for improvement in the design of the FPTU and accurately predicted the static pressure drop as air passed through the unit over the full operating range of the FPTU. Computational fluid dynamics (CFD) models of typical a FPTU were developed and used to investigate opportunities for optimizing the design of FPTUs. The CFD model identified key parameters required to conduct numerical simulations of FPTU and some of the internal components used to manufacture the units. One key internal component was a porous baffle used to enhance mixing when primary air and induced air entered the mixing chamber. The CFD analysis showed that a pressure-drop based on face velocity model could be used to accurately predict the performance of the FPTU. The SDVAV simulation results showed that parallel FPTUs used less energy overall than series systems that used SCR motors as long as primary air leakage was not considered. Simulation results also showed that series ECM FPTUs used about the same amount of energy, within 3 percent, of parallel FPTU even when leakage was not considered. A leakage rate of 10 percent was enough to reduce the performance of the parallel FPTU to the level of the series SCR system and the series ECM FPTUs outperformed the parallel FPTUs at all weather locations used in the study.

Davis, Michael A.

2010-08-01T23:59:59.000Z

275

Extinction Studies of Hydrofluorocarons in Methane/Air and ...  

Science Conference Proceedings (OSTI)

... is a major fire threat in shipboard flammable liquid storage rooms (FLSRs). ... agent volume concentration in air for methane and propane fuels ...

2011-10-13T23:59:59.000Z

276

Air-cleaning apparatus  

SciTech Connect

An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces.

Howard, A.G.

1981-08-18T23:59:59.000Z

277

Generator Fan/Blower Design, Inspection, and Maintenance  

Science Conference Proceedings (OSTI)

Turbo-generator rotor cooling fans and blowers are highly stressed components of a generator rotor. As such, their failures can result in expensive damages and extended outages. This best practices document provides guidelines that help plant managers understand potential failure mechanisms and their root causes, anticipate issues before failures occur, and prepare inspection and contingency plans.The guidelines are applicable to both nuclear and fossil turbo-generator rotors. Both axial ...

2012-12-13T23:59:59.000Z

278

University of Colorado Indoor Air Quality Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Image Courtesy of Ohio Image Courtesy of Ohio State University INDOOR AIR QUALITY Design Goals Design Goals Design Goals Design Goals Integrate technologically and economically innovative, low-energy strategies Minimize occupant distraction User-friendly controls Minimize pollutant sources Bio Bio Bio Bio- - - -S S S S ( ( ( (h h h h) ) ) ) ip ip ip ip indoor air quality features indoor air quality features indoor air quality features indoor air quality features Mechanical Systems Energy Recovery Ventilator Exhaust Fans Heating And Cooling Systems Passive Ventilation Low VOC materials Each of these features is described in more detail below. Mechanical Systems Energy Recovery Ventilator Knowing that our home has a tight envelope, due to our Bio-SIP construction, we needed to use mechanical ventilation to ensure suitable indoor air

279

Study on Energy Saving of the Interlayer Ventilation Walla Used in Clean Operation Rooms  

E-Print Network (OSTI)

Recovery energy of the exhaust in air conditioning is very important to clean operating rooms. In disinfected operating rooms, we often use completely fresh air conditioning system in order to maintain cleanliness. All the return air of the air conditioning must be discharged. For recovering the exhaust energy, whole heat exchangers are used, and they may bring cross-infection in clean operating rooms. Cross-infection would negatively affect cleanness. This paper puts forward an air layer inside of a building's external wall that acts as a passageway for air conditioning exhaust, and also providing a place for the thermal exchange of the air conditioning exhaust. This kind of envelope is named an interlayer ventilation wall. There are two advantages. First, it will recover and reutilize the energy that the air conditioning exhaust takes, avoid cross-infection between the fresh air and the exhaust. Second, it will lower the energy loss of the heat exchange through the envelope. The energy saving effect will be very significant in clean operating rooms.

Feng, J.; Lian, Z.; Hou, Z.

2006-01-01T23:59:59.000Z

280

Control of Computer Room Air Conditioning using IT Equipment Sensors  

E-Print Network (OSTI)

Information and Communications Technology (ICT) managementof Information and Communications Technology Management andInformation and Communications Technology IPMI: Intelligent

Bell, Geoffrey C.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Control of Computer Room Air Conditioning using IT Equipment  

E-Print Network (OSTI)

....................................................................................................................13 Glossary

282

Reading Room | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Freedom of Information Act » Reading Freedom of Information Act » Reading Room Reading Room Welcome to the Freedom of Information Act (FOIA) Electronic Reading Room for the Department of Energy at Headquarters. The FOIA requires certain kinds of documents to be made available to the public for inspection and copying. This is a requirement for agencies of the executive branch of the federal government. The documents that are required to be made available by the FOIA are: Final Opinions [5 USC 552 (a)(2)](A) final opinions, including concurring and dissenting opinions, as well as orders, made in the adjudication of cases. Office of Hearings and Appeal - FOIA Appeals Initial agency determinations in response to FOIA and Privacy Act requests may be appealed to the Office of Hearings and Appeals (OHA). Decisions of

283

Reading Room | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reading Reading Room Reading Room Welcome to the Freedom of Information Act (FOIA) Electronic Reading Room for the Department of Energy at Headquarters. The FOIA requires certain kinds of documents to be made available to the public for inspection and copying. This is a requirement for agencies of the executive branch of the federal government. The documents that are required to be made available by the FOIA are: Final Opinions [5 USC 552 (a)(2)](A) final opinions, including concurring and dissenting opinions, as well as orders, made in the adjudication of cases. Office of Hearings and Appeal - FOIA Appeals Initial agency determinations in response to FOIA and Privacy Act requests may be appealed to the Office of Hearings and Appeals (OHA). Decisions of the OHA constitute the agency's final determinations on requests made under

284

Room temperature terahertz polariton emitter  

SciTech Connect

Terahertz (THz) range electroluminescence from intersubband polariton states is observed in the ultra strong coupling regime, where the interaction energy between the collective excitation of a dense electron gas and a photonic mode is a significant portion of the uncoupled excitation energy. The polariton's increased emission efficiency along with a parabolic electron confinement potential allows operation up to room temperature in a nonresonant pumping scheme. This observation of room temperature electroluminescence of an intersubband device in the THz range is a promising proof of concept for more powerful THz sources.

Geiser, Markus; Scalari, Giacomo; Castellano, Fabrizio; Beck, Mattias; Faist, Jerome [Institute for Quantum Electronics, ETH Zurich, Wolfgang-Pauli-Strasse 16, 8093 Zurich (Switzerland)

2012-10-01T23:59:59.000Z

285

Room ventilation and its influence on the performance of fume cupboards: A parametric numerical study  

Science Conference Proceedings (OSTI)

The three-dimensional turbulent flow in a typical chemical laboratory containing two fume cupboards and furniture is investigated numerically in order to obtain detailed information needed for the improved design of ventilating systems for such rooms. The flow inside the two fume cupboards is simulated simultaneously with the room flow, and its dependence on the flow structure in the room is shown. The flow inside the cupboards and in the vicinity of their sash openings has been found to be essentially three-dimensional. Several room parameters are varied, and a quantitative evaluation of their influence on the flow, the comfort characteristics, and the ventilation efficiency is given. Additional ceiling-mounted openings, which extract room air outside the fume cupboards, can affect the capture efficiency of the cupboards, as well as the quality of the air in the room. It has been found also that small changes in the position of the radial inlet ceiling-mounted diffuser can influence the air quality of the room and at the same time the draught risk. These effects are shown for a given room arrangement. To accommodate the complex geometry, the elliptical nature of the mathematical problem, and the use of a turbulence model, a multigrid acceleration method with 245,000 control volumes is used, allowing CPU times on a workstation to become acceptable.

Denev, J.A.; Durst, F.; Mohr, B. [Friedrich Alexander Univ. Erlangen-Nuernberg, Erlangen (Germany)] [Friedrich Alexander Univ. Erlangen-Nuernberg, Erlangen (Germany)

1997-02-01T23:59:59.000Z

286

Savings in electric cooling energy by the use of a whole-house fan. Final report  

Science Conference Proceedings (OSTI)

Hour-by-hour cooling performances of a typical ranch house, with and without the use of a whole-house fan, were compared for the climate conditions throughout the contiguous United States. The comparative analyses were made by the use of NBSWHF, a modified version of NBSLD, to simulate the complex thermal coupling of whole-house-fan ventilated attic space. The calculations were performed for two operational modes: a cyclic fan mode and a stepwise continuous mode.

Kusuda, T.; Bean, J.W.

1981-05-01T23:59:59.000Z

287

SLAC National Accelerator Laboratory - Meeting Rooms  

NLE Websites -- All DOE Office Websites (Extended Search)

41 144D 3117 30-C Blue Room (20) 41 207 2868 30-C Castle Craigs Conference Room 280B 241 2804 29-D Cedar Room (15) 48 101 3485 30-B CEF Conference Room 35 4A 3534 27-E Controls...

288

Parametric System Curves: Correlations Between Fan Pressure Rise and Flow for Large Commercial Buildings  

E-Print Network (OSTI)

distribution, duct design, system curve, fans, leakage iiifan pressure rise and flow measurements over a range of operating conditions. During design,

Sherman, Max

2010-01-01T23:59:59.000Z

289

Toward green systems for cleanrooms: Energy efficient fan-filter units  

E-Print Network (OSTI)

filter unit (FFU), energy efficiency, green system, electricToward Green Systems for Cleanrooms: Energy Efficient Fan-energy efficient models; Market transformation toward green

Jeng, Ming-Shan; Xu, Tengfang; Lan, Chao-Ho

2004-01-01T23:59:59.000Z

290

NIST Test Fans the Flames for High-Rise Fire Safety  

Science Conference Proceedings (OSTI)

... Once the fires were under way, a variety of ventilation tests were conducted. For example, in one test, a large fan was placed at the front door to ...

2012-12-17T23:59:59.000Z

291

Toward green systems for cleanrooms: Energy efficient fan-filter units  

E-Print Network (OSTI)

Toward Green Systems for Cleanrooms: Energy Efficient Fan-FFU), energy efficiency, green system, electric power use,are challenges and benefits in green designs that integrate

Jeng, Ming-Shan; Xu, Tengfang; Lan, Chao-Ho

2004-01-01T23:59:59.000Z

292

Fallout fans: Negotiations over text integrity in the age of the active audience.  

E-Print Network (OSTI)

??This study investigated how fans and producers of media texts negotiate text integrity, which is defined as an ideal about the validity, wholeness, and truth (more)

Milner, Ryan M.

2008-01-01T23:59:59.000Z

293

DISCRETE-FREQUENCY AND BROADBAND NOISE RADIATION FROM DIESEL ENGINE COOLING FANS.  

E-Print Network (OSTI)

??This effort focuses on measuring and predicting the discrete-frequency and broadband noise radiated by diesel engine cooling fans. Unsteady forces developed by the interaction of (more)

Kim, Geon-Seok

2007-01-01T23:59:59.000Z

294

A Real Reflection of How I Write: Young Adult Female Authors Seizing Agency Through Fan Fiction.  

E-Print Network (OSTI)

??This research project examines ""fan fiction"" (stories based upon existing texts such as movies, books, and video games) written by a young adult female and (more)

Coleman, Susanna

2008-01-01T23:59:59.000Z

295

Failure of a Fan Hub Blade Made of an A713 Al-Zn Alloy  

Science Conference Proceedings (OSTI)

About this Abstract. Meeting, Materials Science & Technology 2012. Symposium, Failure Analysis and Prevention. Presentation Title, Failure of a Fan Hub Blade...

296

Topography based fan control for heavy trucks; Topografibaserad kylflktstyrning fr tunga fordon.  

E-Print Network (OSTI)

?? This thesis is a study of how cooling fan control can be improved by using road topography information. Two such controllers are presented, one (more)

Lerede, Niclas

2009-01-01T23:59:59.000Z

297

Error Sensor Placement for Active Control of an Axial Cooling Fan.  

E-Print Network (OSTI)

??Recent experimental achievements in active noise control (ANC) for cooling fans have used near-field error sensors whose locations are determined according to a theoretical condition (more)

Shafer, Benjamin M 1979-

2007-01-01T23:59:59.000Z

298

DUCTED FAN INLET/EXIT AND ROTOR TIP FLOWIMPROVEMENTS FOR VERTICAL LIFT SYSTEMS.  

E-Print Network (OSTI)

??Ducted fan based vertical lift systems are excellent candidates to be in the group of the next generation vertical lift vehicles, with many potential applications (more)

Akturk, Ali

2010-01-01T23:59:59.000Z

299

Investigation of performance improvements including application of inlet guide vanes to a cross-flow fan .  

E-Print Network (OSTI)

??The inherent characteristics of a cross-flow fan allowing for easy thrust vectoring as well as potential airfoil boundary layer control make it an attractive propulsive (more)

Cordero, Samuel F.

2009-01-01T23:59:59.000Z

300

Arbitrary surface flank milling of fan, compressor, and impeller blades  

SciTech Connect

It is generally conceived that a blade surface is flank millable if it can be closely approximated by a ruled surface; otherwise the slow machining process of point milling has to be employed. However, the authors have now demonstrated that the ruled surface criterion for flank milling is neither necessary nor sufficient. Furthermore, many complex arbitrary surfaces typical of the blades in fans, axial compressors, and centrifugal impellers in aviation gas turbines are actually closely flank millable and can be rendered exactly flank millable with one or more passes per surface often without sacrificing, indeed usually with gain, in performance.

Wu, C.Y. [Pratt and Whitney Canada Incorporated, Longueuil, Quebec, (Canada). Design Engineering

1995-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Impact of the Energy Efficiency Labeling and Standards Program on Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Impact of the Energy Efficiency Labeling and Standards Program on Room Impact of the Energy Efficiency Labeling and Standards Program on Room Air-conditioner in Korea Speaker(s): Jun-Young Choi Date: January 31, 2006 - 12:00pm Location: Bldg. 90 There is a significant amount of trade in energy-using equipment all over the world. A study of trade in air conditioners, refrigerators, electric motors and lighting products found that air-conditioner trade all among all economies was worth about US$35 billion in 2003. Window/wall air conditioners represented about 40% of the value of trade, and other types (split system and ducted types) about 60%. Air conditioner is the one of most energy-consuming equipments in residential sector, which reaches to include air conditioner in MEPS and energy labeling program in many economies. Much of this trade is affected in some way by minimum energy

302

Air Quality  

NLE Websites -- All DOE Office Websites (Extended Search)

Environment Feature Stories Public Reading Room: Environmental Documents, Reports LANL Home Phonebook Calendar Video Community, Environment Environmental Stewardship ...

303

Alliant Energy Interstate Power and Light (Gas and Electric)...  

Open Energy Info (EERE)

Water Heaters, Windows, Whole House Fans, Room Air Conditioners, Geothermal Heat Pumps, LED Lighting, Heat Pump Water Heaters Active Incentive Yes Implementing Sector Utility...

304

Efficient Living Energy Grant (Illinois) | Open Energy Information  

Open Energy Info (EERE)

Motor VFDs, Programmable Thermostats, Refrigerators, Water Heaters, Whole House Fans, LED Exit Signs, Vending Machine Controls, Room Air Conditioners, Geothermal Heat Pumps, LED...

305

Publications  

NLE Websites -- All DOE Office Websites (Extended Search)

Henry C., Steve E. Greenberg, and Corrine Vita. Demonstration of Intelligent Control and Fan Improvements in Computer Room Air Handlers. Berkeley, CA: Lawrence Berkeley National...

306

Standby power use: How big is the problem? What policies and technical solutions can address it?  

E-Print Network (OSTI)

as clothes washers, dishwashers, and room air conditioners.clothes washers, dishwashers, microwaves, ceiling fans withthe end of 2003. The dishwasher test procedure has already

2002-01-01T23:59:59.000Z

307

Perfluorocarbon tracer method for air-infiltration measurements  

DOE Patents (OSTI)

A method of measuring air infiltration rates suitable for use in rooms of homes and buildings comprises the steps of emitting perfluorocarbons in the room to be measured, sampling the air containing the emitted perfluorocarbons over a period of time, and analyzing the samples at a laboratory or other facility.

Dietz, R.N.

1982-09-23T23:59:59.000Z

308

CHANGES IN SANDSTONE DISTRIBUTIONS BETWEEN THE UPPER, MIDDLE, AND LOWER FAN IN THE ARKANSAS JACKFORK GROUP  

E-Print Network (OSTI)

This study is a statistical analysis of the sandstone distribution within the Arkansas Jackfork Group which is a passive margin fan complex. Passive margin fan systems are typically associated with long fluvial transport, fed by deltas, wide shelf, efficient basin transport, that result in a bypassing system. Passive margin fans are generally fine-grained, mud rich, and well sorted. These fans can be separated into three units (upper, middle, and lower fan) based on their location within the fan and how the sediments are deposited. Five outcrops from the Arkansas Jackfork Group have been chosen for this study and each were divided into different facies dependent on sandstone percentages in certain bed sets. The amount of sandstone for each facies was calculated and a statistical approximation for each outcrop was determined. Sandstone distribution curves were made for each outcrop to show a graphic representation of how the sandstone is dispersed. After analyzing different upper, middle, and lower fan outcrops, it is clear there is an obvious change in the sandstone percentage and distribution. The upper fan deposit has an overall sandstone percentage of approximately 77.5% and is deposited in beds that are mainly amalgamated; 10-30m thick. Sandstone is deposited moderately even and is quite concentrated throughout the exposure. The middle fan outcrops contain approximately 72.6% sandstone and show similar patterns, except that the amalgamated sandstone beds are not as thick, 5-15m and contain more shale in between layers. As expected the lower fan outcrop is completely different in both sandstone percentage and distribution. The lower fan has approximately 65.4% sandstone. The distribution of sandstone is more concentrated in each of the individual units, or systems, but the overall complex has two systems separated by a massive marine shale bed, 33.5 m, that contains virtually no sand.

Mack, Clayton P.

2009-05-01T23:59:59.000Z

309

DOE Solar Decathlon: Press Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Press Room Press Room The U.S. Department of Energy Solar Decathlon is an award-winning program that challenges collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive. The winner of the competition is the team that best blends affordability, consumer appeal, and design excellence with optimal energy production and maximum efficiency. The first Solar Decathlon was held in 2002; the competition has since occurred every two years in 2005, 2007, 2009, and 2011. The last event was held at the National Mall's West Potomac Park in Washington, D.C., Sept. 23-Oct. 2, 2011. Solar Decathlon 2013 takes place Oct. 3-13, 2013, at Orange County Great Park in Irvine, California. Open to the public free of charge, the Solar Decathlon gives visitors the

310

News Room | Argonne National Laboratory  

NLE Websites -- All DOE Office Websites (Extended Search)

News Room News Room In a 3D structure of the protein, the binding site is shown in pink, representing a potential drug target. The green molecule shows binding of an antibiotic to the protein. Click to enlarge. Image courtesy of Wladek Minor. Newly ID'd protein provides target for antibiotic-resistant hospital bacterium Full Story » Researchers have made inroads into tackling a bacterium that plagues hospitals and is highly resistant to most antibiotics. Andrey Elagin (left), postdoctoral scholar at the Enrico Fermi Institute at the University of Chicago, and Matthew Wetstein, the Grainger Postdoctoral Fellow at the Enrico Fermi Institute at the University of Chicago, adjust the optics in the Large Area Picosecond Photodetector testing facility. The facility uses extremely short laser pulses to precisely measure the time resolution of the photodetectors. Click to enlarge.

311

Forecasting Uncertain Hotel Room Demand  

E-Print Network (OSTI)

Economic systems are characterized by increasing uncertainty in their dynamics. This increasing uncertainty is likely to incur bad decisions that can be costly in financial terms. This makes forecasting of uncertain economic variables an instrumental activity in any organization. This paper takes the hotel industry as a practical application of forecasting using the Holt-Winters method. The problem here is to forecast the uncertain demand for rooms at a hotel for each arrival day. Forecasting is part of hotel revenue management system whose objective is to maximize the revenue by making decisions regarding when to make rooms available for customers and at what price. The forecast approach discussed in this paper is based on quantitative models and does not incorporate management expertise. Even though, forecast results are found to be satisfactory for certain days, this is not the case for other arrival days. It is believed that human judgment is important when dealing with ...

Mihir Rajopadhye Mounir; Mounir Ben Ghaliay; Paul P. Wang; Timothy Baker; Craig V. Eister

2001-01-01T23:59:59.000Z

312

NETL: NewsRoom - Multimedia  

NLE Websites -- All DOE Office Websites (Extended Search)

NewsRoom NewsRoom Multimedia Now you can download videos to your computer by right clicking the "download" link and selecting the "Save target as" option. It is suggested that mac users use this link. Carbon Cycle Animation Carbon Cycle Animation - 2012 Animation that depicts the carbon cycle as it relates to nature, land use, and energy production. Movie Icon Windows Media Video (WMV-5.7MB) [ view | download ] Earth Day Animation Earth Day Animation - 2011 A compilation of three Earth Day animations that demonstrate being green around your home, office, and community Movie Icon Windows Media Video (WMV-16MB) [ view | download ] Interview with Anthony Cugini Interview with Anthony Cugini - 2011 Interview at the International Pittsburgh Coal Conference with Dr. Cugini regarding Carbon Capture Utilization and Storage technologies.

313

Classified Reading Room Instructions/Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

Classified Reading Room Instructions/Guidelines Classified Reading Room Instructions/Guidelines * Reading Room Points of Contact: Milesha Grier, (202) 586-8210, milesha.gier@nnsa.doe.gov Reading Room Location: DOE Forrestal Building, 1000 Independence Ave., Washington, D.C. Room 4A-045, 4 th Floor, "A" Corridor, Behind Glass Doors, dial 6-8210 Reading Room Availability: By Appointment - Reading Room will be available until RFP Closes except (12/5/11 thru 12/16/11, December 23, January 2, 2012 and January 16, 2012). Reading Room Hours: Morning, 9:00 a.m. - 11:30 a.m.; and Afternoon 1:00 p.m. - 3:30 p.m. Reading Room Will Accommodate: Up to 5-6 people * All personnel must: a. submit a formal Intent to Bid IAW Section L of the RFP, via email to: SEB1@doeal.gov

314

Airvest's Breath of Fresh Air  

NLE Websites -- All DOE Office Websites (Extended Search)

7 7 The Cutting Edge: Airvest's Breath of Fresh Air Spray booths are a common sight in the industrial sector. Designed to remove pollutants during industrial processes such as spray painting or welding, a booth is a rectangular enclosure open on one side where the worker stands, and equipped on the opposite wall with a fan and filter arrangement to suck away the dirty air. The full-size mannequin in these photographs simulates a worker in a spray booth facing the exhaust filters. In experiments designed by LBL researcher Ashok Gadgil, smoke was released in front of the mannequin to simulate the spraying of paint in the booth. The photo on the left shows the spray booth during standard operation. The smoke-representing a pollutant-is entrained in the eddy that forms in

315

Media Room | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Media Room | National Nuclear Security Administration Media Room | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog The National Nuclear Security Administration Media Room Home > Media Room Media Room NNSA's Office of Congressional, Intergovernmental, and Public Affairs regularly updates the web site with current press releases, newsletters,

316

Novel room temperature ferromagnetic semiconductors  

SciTech Connect

Today's information world, bits of data are processed by semiconductor chips, and stored in the magnetic disk drives. But tomorrow's information technology may see magnetism (spin) and semiconductivity (charge) combined in one 'spintronic' device that exploits both charge and 'spin' to carry data (the best of two worlds). Spintronic devices such as spin valve transistors, spin light emitting diodes, non-volatile memory, logic devices, optical isolators and ultra-fast optical switches are some of the areas of interest for introducing the ferromagnetic properties at room temperature in a semiconductor to make it multifunctional. The potential advantages of such spintronic devices will be higher speed, greater efficiency, and better stability at a reduced power consumption. This Thesis contains two main topics: In-depth understanding of magnetism in Mn doped ZnO, and our search and identification of at least six new above room temperature ferromagnetic semiconductors. Both complex doped ZnO based new materials, as well as a number of nonoxides like phosphides, and sulfides suitably doped with Mn or Cu are shown to give rise to ferromagnetism above room temperature. Some of the highlights of this work are discovery of room temperature ferromagnetism in: (1) ZnO:Mn (paper in Nature Materials, Oct issue, 2003); (2) ZnO doped with Cu (containing no magnetic elements in it); (3) GaP doped with Cu (again containing no magnetic elements in it); (4) Enhancement of Magnetization by Cu co-doping in ZnO:Mn; (5) CdS doped with Mn, and a few others not reported in this thesis. We discuss in detail the first observation of ferromagnetism above room temperature in the form of powder, bulk pellets, in 2-3 mu-m thick transparent pulsed laser deposited films of the Mn (<4 at. percent) doped ZnO. High-resolution transmission electron microscopy (HRTEM) and electron energy loss spectroscopy (EELS) spectra recorded from 2 to 200nm areas showed homogeneous distribution of Mn substituting for Zn a 2+ state in the ZnO lattice. Ferromagnetic Resonance (FMR) technique is used to confirm the existence of ferromagnetic ordering at temperatures as high as 425K. The ab initio calculations were found to be consistent with the observation of ferromagnetism arising from fully polarized Mn 2+ state. The key to observed room temperature ferromagnetism in this system is the low temperature processing, which prevents formation of clusters, secondary phases and the host ZnO from becoming n-type. The electronic structure of the same Mn doped ZnO thin films studied using XAS, XES and RIXS, revealed a strong hybridization between Mn 3d and O 2p states, which is an important characteristic of a Dilute magnetic Semiconductor (DMS). It is shown that the various processing conditions like sintering temperature, dopant concentration and the properties of precursors used for making of DMS have a great influence on the final properties. Use of various experimental techniques to verify the physical properties, and to understand the mechanism involved to give rise to ferromagnetism is presented. Methods to improve the magnetic moment in Mn doped ZnO are also described. New promising DMS materials (such as Cu doped ZnO are explored). The demonstrated new capability to fabricate powder, pellets, and thin films of room temperature ferromagnetic semiconductors thus makes possible the realization of a wide range of complex elements for a variety of new multifunctional phenomena related to Spintronic devices as well as magneto-optic components.

Gupta, Amita

2004-11-01T23:59:59.000Z

317

Inlet swirl distortion effects on the generation and propagation of fan rotor shock noise  

E-Print Network (OSTI)

A body-force-based fan model for the prediction of multiple-pure-tone noise generation is developed in this thesis. The model eliminates the need for a full-wheel, three-dimensional unsteady RANS simulation of the fan blade ...

Defoe, Jeff (Jeffrey James)

2011-01-01T23:59:59.000Z

318

Ensure cogen steam supply with fresh-air-fired HRSGs  

Science Conference Proceedings (OSTI)

Heat-recovery steam generators (HRSG) are used to capture thermal energy from the exhaust of gas turbines (GT), thus increasing a plant's overall efficiency. Where additional steaming capacity--above what can be recovered from the GT exhaust--is required, supplementary-fired duct or register burners can be installed. Because gas-turbine exhaust contains a relatively high level of excess air, no additional ambient combustion air is required in most cases; only fuel is needed. This article describes fresh-air-fired HRSGs which are similar to supplementary-fired units, but employ forced- or induced-draft (FD or ID) fans to rapidly convert to fully fired operation in the absence of hot exhaust during GT outages. Thus, fresh-air firing (FAF) is typically employed only at industrial plants where steam needs are more critical than electric-power generation requirements. In most plants using FAF, the GT is isolated using a damper or slide gate during fully fired HRSG operation. In virtually all applications, an FD fan is engaged automatically when a significant drop in exhaust flow is sensed, permitting the conversion to FAF with little or no interruption to the steam supply. However, one plant in Oklahoma employs an ID air fan, which operates even during GT operation, ensuring very rapid, reliable changeover to the FAF mode.

Froemming, J.; Hjalmarson, L.; Houshmand, M.

1993-08-01T23:59:59.000Z

319

Simulation of energy performance of underfloor air distribution (UFAD) systems  

E-Print Network (OSTI)

3. Impact of supply fan design static pressure for UFADdifferences in supply fan design static pressure. Pressuresterminal units. Supply fan design power increases by 32.8

2009-01-01T23:59:59.000Z

320

Improving air handler efficiency in residential HVAC applications  

E-Print Network (OSTI)

of different blade design and fan to housing clearances forimprovements, such as fan blade and cabinet design are hardaerodynamic fan blade and housing design? To investigate

Walker, Iain S.; Mingee, Michael D.; Brenner, Douglas E.

2003-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Impact-resistant boron/aluminum composites for large fan blades  

SciTech Connect

Blade-like specimens were subjected to static ballistic impact testing to determine their relative FOD impact resistance levels. It was determined that a plus or minus 15 deg layup exhibited good impact resistance. The design of a large solid boron/aluminum fan blade was conducted based on the FOD test results. The CF6 fan blade was used as a baseline for these design studies. The solid boron/aluminum fan blade design was used to fabricate two blades. This effort enabled the assessment of the scale up of existing blade manufacturing details for the fabrication of a large B/Al fan blade. Existing CF6 fan blade tooling was modified for use in fabricating these blades.

Oller, T.L.; Salemme, C.T.; Bowden, J.H.; Doble, G.S.; Melnyk, P.

1977-12-01T23:59:59.000Z

322

A passive margin-type submarine fan complex, Permian Ecca Group, South Africa  

Science Conference Proceedings (OSTI)

A submarine fan complex, comprising five arenaceous fan systems separated by basinal shale units, occurs in the southwestern part of the intracratonic Karoo basin in South Africa. Although basin development is related to a subduction zone bordering the palaeo-Pacific ocean to the south of Gondwanaland and the evolution of the Cape Fold Belt, the entire Lower Permian Ecca Group basin-fill succession reflects depositional characteristics of a passive-margin setting. The submarine fan complex, 250 m thick, originated from sediments supplied by Mississippi-type deltas dominating the Ecca coastline. The fine grain-size and low sand/shale ratio of the submarine fan and deltaic deposits reflect the maturity of the ancient river systems. Outcrops of the fan complex are well exposed and cover an area of 650 km{sup 2}. The strata are not affected by folding, and deep erosion allows three-dimensional viewing of mid-fan to outer-fan deposits. Features of interest include stacked lobe deposits displayed along 2.5 km of a 60 m high cliff section, and a transverse cliff section through channel-fill deposits 500 m wide. Paleocurrent directions reveal that each sequence had its own main source area located to the northwest and south of its present geographic location. The cyclic nature of the fan complex is attributed to relative sea-level changes; deposition took place on the basin floor in water depths that do not exceed 500 m. Shoaling of the basin to wave base depths is reflected in the pro-delta and delta front deposits overlying the uppermost fan sequence. Major factors in controlling direction of fan progradation were delta switching and basin floor topography.

Wickens, H.D. (SOEKOR-Pty. Ltd., Parow (South Africa)); Bouma, A.H. (Louisiana State Univ., Baton Rouge (United States))

1991-03-01T23:59:59.000Z

323

Energy Integration Visualization Room (Fact Sheet)  

SciTech Connect

This two-page fact sheet describes the new Energy Integration Visualization Room in the ESIF and talks about some of the capabilities and unique visualization features of the the room.

Not Available

2012-08-01T23:59:59.000Z

324

The room noise criteria (RNC) metric.  

Science Conference Proceedings (OSTI)

The recent ANSI S12.2:2008 room noise criteria contains both a survey and an engineering method to specify room noise criteria. The methods use A?weighting and extended NC

2009-01-01T23:59:59.000Z

325

Tips: Air Ducts | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Ducts Air Ducts Tips: Air Ducts June 24, 2013 - 7:23pm Addthis Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Your air ducts are one of the most important systems in your home, and if the ducts are poorly sealed or insulated they are likely contributing to higher energy bills. Your home's duct system is a branching network of tubes in the walls, floors, and ceilings; it carries the air from your home's furnace and central air conditioner to each room. Ducts are made of sheet metal, fiberglass, or other materials.

326

Room temperature nano- and microstructure photon detectors  

Science Conference Proceedings (OSTI)

The development of room temperature infrared (IR) detectors for wavelengths beyond NIR will open up many applications that are currently limited due to cooling requirements. Three approaches are discussed, which show promise for room temperature IR detection. ... Keywords: Infrared, PbS quantum dot, Room temperature detector, Split-off band, Tunneling quantum dot

A. G. U. Perera; P. V. V. Jayaweera; G. Ariyawansa; S. G. Matsik; K. Tennakone; M. Buchanan; H. C. Liu; X. H. Su; P. Bhattacharya

2009-03-01T23:59:59.000Z

327

FOIA Reading Room - privacy act  

NLE Websites -- All DOE Office Websites (Extended Search)

Reading Room - pricacy act Reading Room - pricacy act CH Frequently Requested Documents Under FOIA Administrative Electronic FOIA Form Privacy Act Advisory (Microsoft Word(tm) document) DOE-CH Government Purchase Card Cardholders: December 2012 CH Organizational Chart: Current Version Policies and Procedures - Office of Science (including Chicago Office) Office of Hearings and Appeals Decisions Department of Justice Cases and Legal Documents Department of Energy Directives DOE Office of Inspector General Reports Responses Under FOIA FY10 Management and Operating Contracts "FY2012 Laboratory Performance Report Cards" The following management and operating prime contracts under the jurisdiction of DOE-CH have been renewed and posted for your convenience. Modifications that change, delete, or add language to any portion of these contracts (referred to as "M" Mods) will be posted as expeditiously as possible after execution. It is at the discretion of the Contractors whether or not they include modifications that change the amount obligated by the Government. Ames Laboratory - Contract No. No.DE-AC02-07CH11358

328

HVAC Radial Air Bearing Heat Exchangers Research Project | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Radial Air Bearing Heat Exchangers Radial Air Bearing Heat Exchangers Research Project HVAC Radial Air Bearing Heat Exchangers Research Project The U.S. Department of Energy is currently conducting research into heating, ventilation, and air conditioning (HVAC) radial air bearing heat exchangers. Rotary air bearing heat exchanger technology simultaneously solves four long standing problems of conventional "fan-plus-finned-heat-sink" heat exchangers. Project Description This project seeks to design, fabricate, and test successive generations of prototype radial air bearing heat exchanger devices based on lessons learned and further insights into device optimization, computational fluid dynamic studies for parametric optimization and determination of scaling laws, and laboratory measurement of flow field and heat transfer

329

Fan-shaped and toric textures of mesomorphic oxadiazoles  

E-Print Network (OSTI)

When a family of non symmetrical heterocycled compounds is investigated, a variety of mesophases can be observed with rather different features. Here we report the behaviour of seven different members among a family of such materials, that consists of mesomorphic oxadiazole compounds. In two of these compounds, the optical microscope investigation shows very interesting behaviours. In their smectic phases, fan-shaped and toric textures, sometimes with periodic instability, are observed. Moreover, the nematic phase displays a texture transition. Texture transitions have been previously observed only inside the nematic phase of some compounds belonging to the families of the oxybenzoic and cyclohexane acids. In these two oxadiazole compounds we can observe what we define as a "toric nematic phase", heating the samples from the smectic phase. The toric nematic texture disappears as the sample is further heated, changing into a smooth texture.

A. Sparavigna; A. Mello; B. Montrucchio

2007-04-11T23:59:59.000Z

330

Reading Room | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Reading Room | National Nuclear Security Administration Reading Room | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog The National Nuclear Security Administration Reading Room Home > About Us > Our Operations > Acquisition and Project Management > Major Contract Solicitations > Environmental Program Services Contract > Reading Room

331

Heating remote rooms in passive solar buildings  

DOE Green Energy (OSTI)

Remote rooms can be effectively heated by convection through a connecting doorway. A simple steady-state equation is developed for design purposes. Validation of a dynamic model is achieved using data obtained over a 13-day period. Dynamic effects are investigated using a simulation analysis for three different cases of driving temperature; the effect is to reduce the temperature difference between the driving room and the remote room compared to the steady-state model. For large temperature swings in the driving room a strategy which uses the intervening door in a diode mode is effective. The importance of heat-storing mass in the remote room is investigated.

Balcomb, J.D.

1981-01-01T23:59:59.000Z

332

Better Unitary Equipment Air-Handlers for Efficiency and Humidity Control  

E-Print Network (OSTI)

Regulatory requirements drive unitary equipment design. For residential equipment, SEER reflects performance at moderate temperatures, and is largely independent of high temperature efficiency and high latent heat removal capability. The test procedure gives too little credit for advanced air handlers that reduce air conditioning load and facilitate adaptive humidity control through automatic fan speed adjustment. DC permanent magnet variable speed motors have much lower market share than less efficient permanent split capacitor designs: changing saves 15% - 25% at high fan speed, and at least 50% at lower speeds (high latent cooling). Humidistats allow dynamic humidity control by reducing air flow, cooling the evaporator. Following market transformation to increase market share, federal equipment stanards should be augmented to include specific air handler air flow efficiency levels, such as 0.2 watts/cfm at size-dependent static pressures. We estimate that customer payback will be less than three years in a mature market.

Sachs, H. M.

2002-01-01T23:59:59.000Z

333

Matchstick: A Room-to-Room Thermal Model for Predicting Indoor Temperature from Wireless Sensor Data  

E-Print Network (OSTI)

Matchstick: A Room-to-Room Thermal Model for Predicting Indoor Temperature from Wireless Sensor present a room-to-room thermal model used to accurately predict temperatures in residential buildings. We that our model can predict future indoor temperature trends with a 90th percentile aggregate error between

Hazas, Mike

334

Public Reading Room: Environmental Documents, Reports  

NLE Websites -- All DOE Office Websites (Extended Search)

Public Reading Room: Environmental Documents, Reports Public Reading Room: Environmental Documents, Reports Public Reading Room: Environmental Documents, Reports Environmental documents and reports are available online. Hard copies are available at the Laboratory's Public Reading Room in Pojoaque, New Mexico. Contact Environmental Communication & Public Involvement P.O. Box 1663 MS M996 Los Alamos, NM 87545 (505) 667-0216 Email Public Reading Room: Environmental Documents, Reports Online Annual Environmental Report Electronic Public Reading Room (EPRR) Plans, Procedures A listing of procedures available in the EPRR Hard copy Public Reading Room 94 Cities of Gold Road Pojoaque, NM Vie Screen reader users: click here for plain HTML Go to Google Maps Home 94 cities of gold Road, Pojoaque, NM Loading... Map Sat Ter Did you mean a different:

335

Feasibility Study: Ductless Hydronic Distribution Systems with Fan Coil Delivery  

SciTech Connect

The primary objectives of this study are to estimate potential energy savings relative to conventional ducted air distribution, and to identify equipment requirements, costs, and barriers with a focus on ductless hydronic delivery systems that utilize water-to-air terminal units in each zone. Results indicate that annual heating and cooling energy use can be reduced by up to 27% assuming replacement of the conventional 13 SEER heat pump and coil with a similarly rated air-to-water heat pump.

Springer, D.; Dakin, B.; Backman, C.

2012-07-01T23:59:59.000Z

336

Sorption of organic gases in a furnished room  

NLE Websites -- All DOE Office Websites (Extended Search)

a furnished room a furnished room Title Sorption of organic gases in a furnished room Publication Type Journal Article LBNL Report Number LBNL-53943 Year of Publication 2004 Authors Singer, Brett C., Kenneth L. Revzan, Toshifumi Hotchi, Alfred T. Hodgson, and Nancy J. Brown Journal Atmospheric Environment Volume 38 Start Page Chapter Issue 16 Pagination 2483-2494 Abstract We present experimental data and semi-empirical models describing the sorption of organic gases in a simulated indoor residential environment. Two replicate experiments were conducted with 20 volatile organic compounds (VOCs) in a 50-m3 room finished with painted wallboard, carpet and cushion, draperies and furnishings. The VOCs span a wide volatility range and include ten Hazardous Air Pollutants. VOCs were introduced to the static chamber as a pulse and their gas-phase concentrations were measured during a net adsorption period and a subsequent net desorption period. Three sorption models were fit to the measured concentrations for each compound to determine the simplest formulation needed to adequately describe the observed behavior. Sorption parameter values were determined by fitting the models to adsorption period data then checked by comparing measured and predicted behavior during desorption. The adequacy of each model was evaluated using a goodness of fit parameter calculated for each period. Results indicate that sorption usually does not greatly affect indoor concentrations of methyl-tert-butyl ether, 2-butanone, isoprene and benzene. In contrast, sorption appears to be a relevant indoor process for many of the VOCs studied, including C8-C10 aromatic hydrocarbons (HC), terpenes, and pyridine. These compounds sorbed at rates close to typical residential air change rates and exhibited substantial sorptive partitioning at equilibrium. Polycyclic aromatic HCs, aromatic alcohols, ethenylpyridine and nicotine initially adsorbed to surfaces at rates of 1.5 to >6 h-1 and partitioned 95 to >99% in the sorbed phase at equilibrium

337

NEPA Reading Room | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Reading Room | National Nuclear Security Administration Reading Room | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog NEPA Reading Room Home > About Us > Our Operations > NNSA Office of General Counsel > National Environmental Policy Act (NEPA) > NEPA Reading Room NEPA Reading Room Welcome to the National Nuclear Security Administration's NEPA Reading

338

Property:Building/SPBreakdownOfElctrcityUseKwhM2Fans | Open Energy  

Open Energy Info (EERE)

Fans Fans Jump to: navigation, search This is a property of type String. Fans Pages using the property "Building/SPBreakdownOfElctrcityUseKwhM2Fans" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 5.21311928139 + Sweden Building 05K0002 + 18.5995610535 + Sweden Building 05K0003 + 20.3514016294 + Sweden Building 05K0004 + 8.08671679198 + Sweden Building 05K0005 + 16.0166245259 + Sweden Building 05K0006 + 10.358795651 + Sweden Building 05K0007 + 8.3953561818 + Sweden Building 05K0008 + 9.28527472527 + Sweden Building 05K0009 + 12.8398873749 + Sweden Building 05K0010 + 20.0966982674 + Sweden Building 05K0011 + 6.90408963585 + Sweden Building 05K0012 + 8.60719192175 + Sweden Building 05K0013 + 16.7539365907 +

339

Property:Building/SPBreakdownOfElctrcityUseKwhM2CirculationFans | Open  

Open Energy Info (EERE)

CirculationFans CirculationFans Jump to: navigation, search This is a property of type String. Circulation fans Pages using the property "Building/SPBreakdownOfElctrcityUseKwhM2CirculationFans" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 13.3422495258 + Sweden Building 05K0002 + 0.0 + Sweden Building 05K0003 + 2.80646609789 + Sweden Building 05K0004 + 8.95823904901 + Sweden Building 05K0005 + 5.55016340076 + Sweden Building 05K0006 + 6.81308969891 + Sweden Building 05K0007 + 2.02541916787 + Sweden Building 05K0008 + 0.625641025641 + Sweden Building 05K0009 + 7.59721281624 + Sweden Building 05K0010 + 0.0 + Sweden Building 05K0011 + 0.757191316527 + Sweden Building 05K0012 + 6.04077487892 + Sweden Building 05K0013 + 0.767224182906 +

340

Dehumidification Performance of Unitary Rooftop Air Conditioning Systems: K-Mart Demonstration  

Science Conference Proceedings (OSTI)

Applying various HVAC options--including heat pipe heat exchangers, reduced airflow, low temperature air, and modified fan operation--reduced the average relative humidity of a K-Mart store on the Mississippi coast during the hot humid summer season to below 50 percent. This demonstration will help utilities recommend the best practices for their retail customers.

1996-07-26T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Validation and Application of the Room Model of the Modelica Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Validation and Application of the Room Model of the Modelica Buildings Validation and Application of the Room Model of the Modelica Buildings Library Title Validation and Application of the Room Model of the Modelica Buildings Library Publication Type Conference Proceedings LBNL Report Number LBNL-5932E Year of Publication 2012 Authors Nouidui, Thierry Stephane, Kaustubh Phalak, Wangda Zuo, and Michael Wetter Conference Name Proc. of the 9th International Modelica Conference Date Published 09/2012 Conference Location Munich, Germany Abstract The Modelica Buildings library contains a package with a model for a thermal zone that computes heat transfer through the building envelope and within a room. It considers various heat transfer phenomena of a room, including conduction, convection, short-wave and long-wave radiation. The first part of this paper describes the physical phenomena considered in the room model. The second part validates the room model by using a standard test suite provided by the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). The third part focuses on an application where the room model is used for simulation-based controls of a window shading device to reduce building energy consumption.

342

Air Quality  

NLE Websites -- All DOE Office Websites (Extended Search)

What We Monitor & Why » What We Monitor & Why » Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data monitoring for particulate matter An air monitoring field team member tests one of LANL's tapered element oscillating microbalance samplers, which collects real-time particulate matter data. Contact Environmental Communication & Public Involvement P.O. Box 1663 MS M996 Los Alamos, NM 87545 (505) 667-0216 Email LANL monitors air quality 24 hours a day, 365 days a year. Why we monitor air LANL monitors many different pathways in order to assess their impact on workers, the public, animals, and plants. We monitor the air around the Laboratory to ensure our operations are not affecting the air of nearby

343

Quiet Computing with BSD: Fan control with sysctl hw.sensors.  

E-Print Network (OSTI)

We will discuss the topic of fan control and introduce sysctl-based interfacing with the fancontrolling capabilities of microprocessor system hardware monitors on OpenBSD. The discussed prototype implementation reduces the noise and power-consumption characteristics in fans of personal computers, especially of those PCs that are designed from off-the-shelf components. We further argue that our prototype is easier, robuster and more intuitive to use compared to solutions available elsewhere. 1.

Constantine A. Murenin; Raouf Boutaba

2010-01-01T23:59:59.000Z

344

Root-Cause Failure Analysis: Fossil-Fired Power Plant Draft Fans  

Science Conference Proceedings (OSTI)

This report describes the collection and analysis of fan-related outage data for 61 large fossil fuel steam power plants. The outage causes are ranked in terms of their impact on production, and a systematic search for generic root causes is described. Recommendations are made for short-term corrective measures and for longer-term research efforts to significantly improve fan system reliability.

1983-07-01T23:59:59.000Z

345

Application of Adjustable Speed Drives to Induced Draft Fans at NSP-SHERCO Power Plant  

Science Conference Proceedings (OSTI)

Induced draft (ID) fans on power boilers control the flow of flue gasses from the boiler to the atmosphere-and their smooth operation is essential to the efficient operation of any generating station. Adjustable speed drive (ASD) control of an electric motor ID fan can provide significant energy savings while increasing the accuracy and precision of boiler draft and fuel gas flow regulation. This study quantified the energy savings and identified other benefits of applying ASDs to four existing electric-...

1999-10-19T23:59:59.000Z

346

Generation of fan-states of radiation field in a cavity  

E-Print Network (OSTI)

A scheme of generating recently introduced fan-states | \\alpha, 2k>_F (\\alpha is complex, k=1,2,3,...) is proposed basing on a \\Lambda-type atom-cavity field interaction. We show that with suitable atomic preparations and measurements a passage of a sequence of N atoms through a cavity may transform an initial field coherent state | \\alpha> to a fan-state | \\alpha, 2k>_F with k=2^{N-2}.

Nguyen Ba An; Truong Minh Duc

2001-11-30T23:59:59.000Z

347

Rating of Mixed Split Residential Air Conditioners  

E-Print Network (OSTI)

A methodology is presented for rating the performance of mixed, split residential air conditioners. The method accounts for the impact on system performance of the indoor evaporator, expansion device and fan; three major components that are likely to be substituted for the matched components in a mixed system. The method allows calculation of capacity at 95F rating point and seasonal energy efficiency ratio, SEER, without performing laboratory test of the complete system. Limitations of the procedure, present work, and anticipated improvements are also discussed.

Domanski, P. A.

1988-01-01T23:59:59.000Z

348

Data for Room Fire Model Comparisons  

Science Conference Proceedings (OSTI)

... of the burn room; and, possibly, a load platform. ... by the use of the oxygen consumption principle ... be used to estimate the rate of energy production of ...

2004-10-05T23:59:59.000Z

349

NEPA Reading Room | National Nuclear Security Administration  

NLE Websites -- All DOE Office Websites (Extended Search)

NEPA Reading Room | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing...

350

NEPA Reading Room | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Reading Room | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our...

351

Cold air distribution in office buildings: Technology assessment for California  

DOE Green Energy (OSTI)

This paper presents the results of a study to assess the current state of practice, and energy and operating cost implications of cold air distribution in California, and to identify the key research needs for the continued development of this technology in new commercial buildings in the state. Whole-building energy simulations were made to compare the energy performance of a prototypical office building in three California climates using conventional and cold air distribution, with and without ice storage, to show the impacts of load shifting, energy use, and utility costs for three typical utility rate structures. The merits of economizers and fan-powered mixing boxes were also studied when used in conjunction with cold air delivery. A survey was conducted to assess the perceived strengths and limitations of this technology, perceived barriers to its widespread use, and user experience. The survey was based on interviews with consulting engineers, equipment manufacturers, researchers, utility representatives, and other users of cold air distribution technology. Selected findings from the industry survey are also discussed. Cold air distribution (CoAD) is found to always reduce fan energy use in comparison to conventional 55[degrees]F (13[degrees]C) air distribution systems, when conditioned air is delivered directly to the space (no fan-powered mixing boxes). Total building energy use for ice storage/CoAD systems was always higher than a well-designed conventional system, but significantly lower than a commonly-installed packaged system. When a favorable utility rate structure was applied, the load-shifting benefits of ice storage/CoAD systems produced the lowest annual operating costs of all system-plant configurations studied.

Bauman, F.S.; LaBege, P. (California Univ., Berkeley, CA (United States). Center for Environmental Design Research); Borgers, T. (Humboldt State Univ., Arcata, CA (United States). Dept. of Chemistry); Gadgil, A.J. (Lawrence Berkeley Lab., CA (United States))

1992-06-01T23:59:59.000Z

352

Applicability of fan spray nozzles to stripping insoluble gases from viscous liquids  

SciTech Connect

Fan spray nozzle stripping appears to be a practical technique for separating dilute volatile solutes from nonvolatile solvents. In particular this technique can be used to strip molecular tritium and tritium fluoride at extremely small concentration (in the parts per million range) from molten salts used as blanket materials in a fusion reactor. Under adjusted operating conditions of the fan spray as it leaves the nozzle, a high percentage of the theoretically maximum achievable stripping would take place from the expanding sheet of the fan spray as it leaves the nozzle and before it breaks up. Although the only available experimental data are for aqueous solutions, a new theoretical analysis of the fan spray sheet demonstrates the applicability of this technique to nonaqueous liquids. The equation derived from this analysis relates the theoretically achievable mass transfer efficiency to the properties of the liquid flowing through the fan spray nozzle and to the operating conditions of the nozzle. Any fluid with viscosity higher than or equal to that of water would be expected to follow this equation as long as a fan-shaped sheet is formed under the operating conditions of the nozzle.

Tseng, H.H.; Johnson, E.F.

1983-08-01T23:59:59.000Z

353

The noise power spectrum in CT with direct fan beam reconstruction  

Science Conference Proceedings (OSTI)

The noise power spectrum (NPS) is a useful metric for understanding the noise content in images. To examine some unique properties of the NPS of fan beam CT, the authors derived an analytical expression for the NPS of fan beam CT and validated it with computer simulations. The nonstationary noise behavior of fan beam CT was examined by analyzing local regions and the entire field-of-view (FOV). This was performed for cases with uniform as well as nonuniform noise across the detector cells and across views. The simulated NPS from the entire FOV and local regions showed good agreement with the analytically derived NPS. The analysis shows that whereas the NPS of a large FOV in parallel beam CT (using a ramp filter) is proportional to frequency, the NPS with direct fan beam FBP reconstruction shows a high frequency roll off. Even in small regions, the fan beam NPS can show a sharp transition (discontinuity) at high frequencies. These effects are due to the variable magnification and therefore are more pronounced as the fan angle increases. For cases with nonuniform noise, the NPS can show the directional dependence and additional effects.

Baek, Jongduk; Pelc, Norbert J. [Department of Radiology, Stanford University, Stanford, California 94305 (United States); Department of Radiology, Stanford University, Stanford, California 94305 (United States); Department of Electrical Engineering, Stanford University, Stanford, California 94305 (United States) and Department of Bioengineering, Stanford University, Stanford, California 94305 (United States)

2010-05-15T23:59:59.000Z

354

Channel complex architecture of fine-grained submarine fans at the base-of-slope  

Science Conference Proceedings (OSTI)

The fan-valley or upper fan channel connects the submarine canyon on the outer shelf-upper slope to the basin proper. It is an erosionally-formed channel that is a conduit for sediment transported to the basin. The valley may widen where it enters the base-of-slope area. Most of the density flows are much smaller than the initial flow and therefore will not occupy the entire width of the upper fan channel. Smaller individual channels will be constructed resulting in a massive fill comprised of amalgamated sandstones. Sand-rich levees and overbank deposits flank each channel. Channel switching may take place toward locations with a slightly steeper gradient. These switches most likely result from irregular flow successions and different flow sizes. Erosion between successive channels is common, removing part of the channel fill and levee-overbank deposits. This results in a disorderly distribution of low-permeability barriers creating local obstruction to connectivity. A study of the sedimentological architecture of the updip mid-fan channel complex was conducted on cliff sections of the Permian Tanqua Karoo subbasin in South Africa, and in Big Rock Quarry in North Little Rock, Arkansas. Seismic records of the base-of-slope of the Mississippi Fan show a widening pattern, and of the Bryant Canyon Fan Complex south of the Sigsbee Escarpment the channel complexity. Integration of seismic data in outcrop observations improves our understanding of the complexity of many good reservoir sands, typically overlain by slope shales.

Bouma, A.H. [Louisiana State Univ., Baton Rouge, LA (United States); Gwang, H. [Kunsan National Univ. (Korea, Democratic People`s Republic of); Van Antwerepen, O. [Univ. of Port Elizabeth (South Africa)] [and others

1995-10-01T23:59:59.000Z

355

Ga Air Compressor, Ga Air Compressor Products, Ga Air ...  

U.S. Energy Information Administration (EIA)

Ga Air Compressor, You Can Buy Various High Quality Ga Air Compressor Products from Global Ga Air Compressor Suppliers and Ga Air Compressor ...

356

Limit processes for TASEP with shocks and rarefaction fans  

E-Print Network (OSTI)

We consider the totally asymmetric simple exclusion process (TASEP) with two-sided Bernoulli initial condition, i.e., with left density rho_- and right density rho_+. We consider the associated height function, whose discrete gradient is given by the particle occurrences. Macroscopically one has a deterministic limit shape with a shock or a rarefaction fan depending on the values of rho_{+/-}. We characterize the large time scaling limit of the fluctuations as a function of the densities rho_{+/-} and of the different macroscopic regions. Moreover, using a slow decorrelation phenomena, the results are extended from fixed time to the whole space-time, except along the some directions (the characteristic solutions of the related Burgers equation) where the problem is still open. On the way to proving the results for TASEP, we obtain the limit processes for the fluctuations in a class of corner growth processes with external sources, of equivalently for the last passage time in a directed percolation model with two-sided boundary conditions. Additionally, we provide analogous results for eigenvalues of perturbed complex Wishart (sample covariance) matrices.

Ivan Corwin; Patrik L. Ferrari; Sandrine Pch

2010-02-18T23:59:59.000Z

357

Determining Critical Pressure and Duct Leakage in VAV Air-Handling Units  

NLE Websites -- All DOE Office Websites (Extended Search)

Determining Critical Pressure and Duct Leakage in VAV Air-Handling Units Determining Critical Pressure and Duct Leakage in VAV Air-Handling Units Speaker(s): Clifford Federspiel Date: December 3, 2003 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Nance Matson Fans for moving air in buildings use a significant amount of energy. It is well known that fan energy use in variable-air-volume (VAV) systems can be reduced by resetting the supply duct pressure. The standard way to reset duct pressure is by controlling the most-open terminal damper to a nearly open position. Most systems can't measure terminal damper positions, so pressures are either not reset at all or use ad hoc resetting strategies that are configured sub-optimally. In this seminar I will describe a new method of determining the critical supply duct pressure for VAV systems.

358

The Live Room: transducing resonant architectures  

Science Conference Proceedings (OSTI)

The Live Room was a temporary site-specific installation presented in building N51, room 117 on the MIT campus on 7 May 1998 and concluded on 10 June 1998. Using small acoustic-intensifying equipment which mounted directly to the structure of ...

Mark Bain

2003-08-01T23:59:59.000Z

359

A study towards applying thermal inertia for energy conservation in rooms  

Science Conference Proceedings (OSTI)

We are in an age where people are paying increasing attention to energy conservation around the world. The heating and air-conditioning systems of buildings introduce one of the largest chunks of energy expenses. In this article, we make a key observation ... Keywords: Thermal inertia, energy conservation, room management, wireless sensor networks

Yi Yuan; Dawei Pan; Dan Wang; Xiaohua Xu; Yu Peng; Xiyuan Peng; Peng-Jun Wan

2013-11-01T23:59:59.000Z

360

DOE-ID FOIA Reading Room  

NLE Websites -- All DOE Office Websites (Extended Search)

Reading Room Reading Room READING ROOM Eectronic Freedom of Information Act, E-FOIA RECORDS UNDER THE E-FOIA The Electronic Freedom of Information Act Amendments of 1996 addresses the issues and procedural aspects of FOIA administration. The amendment: defines the term "record" as including "any information that would be an agency record subject to the requirements of the FOIA when maintained by an agency in any format, including an electronic format; addresses the form or format in which a requested record is disclosed providing the record is readily reproducible by the agency in the requestor's desired form or format; directs Federal agencies to maintain both conventional reading rooms and electronic reading rooms to meet FOIA responsibilities.

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Los Alamos test-room results  

DOE Green Energy (OSTI)

Fourteen Los Alamos test rooms have been operated for several years; this paper covers operation during the winters of 1980-81 and 1981-82. Extensive data have been taken and computer analyzed to determine performance parameters such as efficiency, solar savings fraction, and comfort index. The rooms are directly comparable because each has the same net coefficient and solar collection area and thus the same load collector ratio. Configurations include direct gain, unvented Trombe walls, water walls, phase change walls, and two sunspace geometries. Strategies for reducing heat loss include selective surfaces, two brands of superglazing windows, a heat pipe system, and convection-suppression baffles. Significant differences in both backup heat and comfort are observed among the various rooms. The results are useful, not only for direct room-to-room comparisons, but also to provide data for validation of computer simulation programs.

McFarland, R.D.; Balcomb, J.D.

1982-01-01T23:59:59.000Z

362

Ductless Mini-Split Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners August 9, 2012 - 4:05pm Addthis A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. What does this mean for me? A ductless mini-split air conditioner is easier to install than a central air conditioning system. A ductless mini-split air conditioner provides zoned air conditioning without ducting. A ductless mini-split air conditioner is relatively easy to install and does not provide an entry point for intruders as some room air conditioners do. Ductless, mini split-system air-conditioners (mini splits) have numerous

363

Ductless Mini-Split Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners August 9, 2012 - 4:05pm Addthis A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. What does this mean for me? A ductless mini-split air conditioner is easier to install than a central air conditioning system. A ductless mini-split air conditioner provides zoned air conditioning without ducting. A ductless mini-split air conditioner is relatively easy to install and does not provide an entry point for intruders as some room air conditioners do. Ductless, mini split-system air-conditioners (mini splits) have numerous

364

Capture and Use of Coal Mine Ventilation Air Methane  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., in conjunction with MEGTEC Systems, Inc., and the U.S. Department of Energy with the U.S. Environmental Protection Agency, designed, built, and operated a commercial-size thermal flow reversal reactor (TFRR) to evaluate its suitability to oxidize coal mine ventilation air methane (VAM). Coal mining, and particularly coal mine ventilation air, is a major source of anthropogenic methane emissions, a greenhouse gas. Ventilation air volumes are large and the concentration of methane in the ventilation air is low; thus making it difficult to use or abate these emissions. This test program was conducted with simulated coal mine VAM in advance of deploying the technology on active coal mine ventilation fans. The demonstration project team installed and operated a 30,000 cfm MEGTEC VOCSIDIZER oxidation system on an inactive coal mine in West Liberty, WV. The performance of the unit was monitored and evaluated during months of unmanned operation at mostly constant conditions. The operating and maintenance history and how it impacts the implementation of the technology on mine fans were investigated. Emission tests showed very low levels of all criteria pollutants at the stack. Parametric studies showed that the equipment can successfully operate at the design specification limits. The results verified the ability of the TFRR to oxidize {ge}95% of the low and variable concentration of methane in the ventilation air. This technology provides new opportunities to reduce greenhouse gas emissions by the reduction of methane emissions from coal mine ventilation air. A large commercial-size installation (180,000 cfm) on a single typical mine ventilation bleeder fan would reduce methane emissions by 11,000 to 22,100 short tons per year (the equivalent of 183,000 to 366,000 metric tonnes carbon dioxide).

Deborah Kosmack

2008-10-31T23:59:59.000Z

365

Hot Air Stratification of Ceiling Air Supply in a Large Space Building  

E-Print Network (OSTI)

The effects of different states of air supply and airflow patterns on temperature gradient distribution are calculated and analyzed with the help of FFSV3.0 software, using the LB models and LES and RANS methods. An experimental study with upper supply and upper return air flow was performed in normal airflow room. The results were compared with numerical simulation results and were found to agree well. Information on delaminating laws, and measurements of the relationship of delaminating heights and air supply temperature and velocity is also presented. According to the simulation results, a formula that avoids hot air delaminating in ceiling air supply is derived, which can guide engineering design.

Wang, H.; Wang, Z.; Liu, C.

2006-01-01T23:59:59.000Z

366

Characteristics of some submarine fan channels, Permian Ecca Group, South Africa  

Science Conference Proceedings (OSTI)

The vary well exposed submarine fan complex in the southwestern part of the Karoo basin permits close examination of channel-fills and in places their associated overbank deposits. The complex comprises five arenaceous fan systems some of which attain 60 m in thickness. The fans are vertically stacked and separated by basinal shale deposits; each system with its own direction of growth. The association of channelized sandstone bodies and thin-bedded sandstone and shale packages in an updip position from predominantly stacked lobe deposits suggest preservation of middle fan settings. A 500 m wide, 20 m thick channel-fill consisting massive amalgamated sandstone beds occupying the channel thalweg occurs in a setting dominated by thin-bedded, ripple-laminated sandstone and shale. Gradual thinning of the channel-fill beds toward the channel edges, lack of internal lateral accretion, and a high width to depth ratio suggests a low sinuous to straight channel. The channel-fill is capped by an abandonment facies characterized by ripple-laminated sandstone and shale. Stacked, laterally offset channel-fill deposits with highly erosional contacts and typical well-bedded overbank deposits form channel-overbank complexes and characterize the mid-fan region of the uppermost fan system. Palaeocurrent directions and gradual diminishing of bed-thickness away from the generally massively bedded, amalgamated channel-fill sandstones confirm a simultaneous channel/overbank origin for these deposits. Levee morphology has not been recognized. Both examples of channel-fills cited reveal part of the complexity of the channelized portions of submarine fans and hence the implications thereof in exploring for hydrocarbon reservoirs.

Bouma, A.H. (Louisiana State Univ., Baton Rouge (United States)); Dev Wickens, H. (Soekor, Parow (South Africa))

1991-03-01T23:59:59.000Z

367

The Effect of Alternate Defrost Strategies on the Reverse-Cycle Defrost of an Air-Source Heat Pump  

E-Print Network (OSTI)

The effect of alternate defrost strategies on the transient performance of the air-source heat pump during the reverse-cycle defrost was investigated. Tests of a base-case heat pump configuration and defrost strategy were completed to provide a basis for performance evaluations of the alternate defrost strategies. The compressor and indoor coil fan operated continuously in the base-case defrost strategy, and the outdoor coil fan was stopped. Alternate defrost strategies utilized variations in fan and compressor operation during and after the defrost. Pre-starting of the outdoor coil fan prior to termination of the reverse-cycle defrost reduced pressure spikes commonly seen at defrost termination in the base-case defrost strategy. A strategy in which the compressor was stopped and the outdoor coil was allowed to drain of melted frost during the last three minutes of the defrost improved overall cyclic performance. Strategies which involved stopping of the indoor fan during defrost or delaying the start of the outdoor fan following defrost termination had a negative impact on defrost performance. A final strategy involved down-sizing of the heat pump compressor from 3.0 tons (36,000 btu/hr) capacity to 2.5 tons capacity. This alternate configuration had a comparable overall performance with the base-case while having a reduced frequency of required defrost periods.

Schliesing, J. S.

1988-08-01T23:59:59.000Z

368

LETTER REPORT INDEPENDENT VERIFICATION OF THE HIGH FLUX BEAM REACTOR DECOMMISSIONING PROJECT FAN HOUSE, BUILDING 704 BNL  

Science Conference Proceedings (OSTI)

5098-LR-01-0 -LETTER REPORT INDEPENDENT VERIFICATION OF THE HIGH FLUX BEAM REACTOR DECOMMISSIONING PROJECT FAN HOUSE, BUILDING 704 BROOKHAVEN NATIONAL LABORATORY

P.C. Weaver

2010-10-22T23:59:59.000Z

369

Caratterizzazione del rumore generato dal fan di motori aeronautici e Metodo inverso per la ricostruzione della sorgente.  

E-Print Network (OSTI)

??Il seguente lavoro tratta una procedura per la ricostruzione della sorgente acustica del fan di un motore turbofan per uso aeronautico mediante metodo inverso. Tale (more)

BIANCHI, FRANCESCO

2009-01-01T23:59:59.000Z

370

Microwave remote sensing of ionized air.  

SciTech Connect

We present observations of microwave scattering from ambient room air ionized with a negative ion generator. The frequency dependence of the radar cross section of ionized air was measured from 26.5 to 40 GHz (Ka-band) in a bistatic mode with an Agilent PNA-X series (model N5245A) vector network analyzer. A detailed calibration scheme is provided to minimize the effect of the stray background field and system frequency response on the target reflection. The feasibility of detecting the microwave reflection from ionized air portends many potential applications such as remote sensing of atmospheric ionization and remote detection of radioactive ionization of air.

Liao, S.; Gopalsami, N.; Heifetz, A.; Elmer, T.; Fiflis, P.; Koehl, E. R.; Chien, H. T.; Raptis, A. C. (Nuclear Engineering Division)

2011-07-01T23:59:59.000Z

371

REVIEW OF AIR FLOW MEASUREMENT TECHNIQUES  

Office of Scientific and Technical Information (OSTI)

9747 9747 Review of Airflow Measurement Techniques Jennifer McWilliams Energy Performance of Buildings Group Environmental Energy Technologies Division Lawrence Berkeley National Laboratory Berkeley, CA 94720 December 1, 2002 Abstract Airflow measurement techniques are necessary to determine the most basic of indoor air quality questions: "Is there enough fresh air to provide a healthy environment for the occupants of the building?" This paper outlines airflow measurement techniques, but it does not make recommendations for techniques that should be used. The airflows that will be discussed are those within a room or zone, those between rooms or zones, such as through doorways (open or closed) or passive vents, those between the building and

372

Stay Cool for Less Money with a Ceiling Fan | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Stay Cool for Less Money with a Ceiling Fan Stay Cool for Less Money with a Ceiling Fan Stay Cool for Less Money with a Ceiling Fan May 12, 2009 - 5:00am Addthis Allison Casey Senior Communicator, NREL After a few late snowstorms here in Colorado, I am more than ready to turn off the heat and enjoy some warm spring weather. We haven't had any heat waves here yet, but many of you have already been trying to stay cool; our friends in Washington, D.C. were sweltering (by comparison) in 90+°F weather just a couple short weeks ago! Whether you're still anticipating snow or have broken out the sandals and tank tops, you may be starting to think about keeping your summer cooling costs down. One easy way to keep cool while saving money is using a ceiling fan. Did you know that a ceiling fan could allow you to raise the thermostat

373

Transactions of the ASAE Vol. 45(5): xxxxxx E 2002 American Society of Agricultural Engineers ISSN 00012351 1  

E-Print Network (OSTI)

.6 m/s and 4.1 mm/s, respectively, based on the designed fan performance (Keener et al., 1999 composting in windrows. All exhaust fans in the HRHB are located in the lower story. Fresh air is drawn in greenhouses, animal buildings, and human rooms (Lee and Short, 2000; Fan, 1995; Quinn and Baker, 1997; Jackson

Michel Jr., Frederick C.

374

Design of the CTX diagnostics screen room  

DOE Green Energy (OSTI)

The design of a shielded enclosure (or screen room) to house data acquisition equipment in an area in which substantial, time varying magnetic fields are present and capable of producing significant interference is described.

Chandler, G.I. II

1981-01-01T23:59:59.000Z

375

NREL Provides Guidance to Improve Air Mixing and Thermal Comfort in Homes (Fact Sheet)  

DOE Green Energy (OSTI)

NREL research determines optimal HVAC system design for proper air mixing and thermal comfort in homes. As U.S. homes become more energy efficient, heating, ventilation, and cooling (HVAC) systems will be downsized, and the air flow volumes required to meet heating and cooling loads may be too small to maintain uniform room air mixing-which can affect thermal comfort. Researchers at the National Renewable Energy Laboratory (NREL) evaluated the performance of high sidewall air supply inlets and confirmed that these systems can achieve good air mixing and provide suitable comfort levels for occupants. Using computational fluid dynamics modeling, NREL scientists tested the performance of high sidewall supply air jets over a wide range of parameters including supply air temperature, air velocity, and inlet size. This technique uses the model output to determine how well the supply air mixes with the room air. Thermal comfort is evaluated by monitoring air temperature and velocity in more than 600,000 control volumes that make up the occupied zone of a single room. The room has an acceptable comfort level when more than 70% of the control volumes meet the comfort criteria on both air temperature and velocity. The study shows that high sidewall supply air jets achieve uniform mixing in a room, which is essential for providing acceptable comfort levels. The study also provides information required to optimize overall space conditioning system design in both heating and cooling modes.

Not Available

2012-02-01T23:59:59.000Z

376

A Comparative Study for the Air Distribution System of a Cleanroom with  

NLE Websites -- All DOE Office Websites (Extended Search)

A Comparative Study for the Air Distribution System of a Cleanroom with A Comparative Study for the Air Distribution System of a Cleanroom with High Cooling Load and Airborne Molecular Sources Speaker(s): Shih-Cheng Hu Date: June 20, 2008 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Tim Xu With rapid change of production line in Taiwan IT Industries; increased productivity/flexibility in the same cleanroom space is required urgently. We have systematically compared two cleanroom ventilation systems i.e. conventional and ceiling return system. The wall return system has fixed location of Fan filter unit (FFU), return air shaft/wall and dry coiling coil. The ceiling return system with a specially designed Fan Filter Dry Coil Unit (FFDCU) installed just above a production tool with high heat/particle sources. For a wall return system, reduced flexibility and

377

State-of-the-Art in Residential and Small Commercial Air Handler Performance  

E-Print Network (OSTI)

with PSC motors. New fan designs The prototype testingshowing different blade design and fan to housing clearancesequipment design (not putting large fans in small cabinets).

Walker, Iain S.

2005-01-01T23:59:59.000Z

378

PCS Nitrogen: Combustion Fan System Optimization Improves Performance and Saves Energy at a Chemical Plant  

Science Conference Proceedings (OSTI)

This U.S. Department of Energy Industrial Technologies Program case study describes how, in 2003, PCS Nitrogen, Inc., improved the efficiency of the combustion fan on a boiler at the company's chemical fertilizer plant in Augusta, Georgia. The project saved $420,000 and 76,400 million British thermal units (MBtu) per year. In addition, maintenance needs declined, because there is now less stress on the fan motor and bearings and less boiler feed water usage. This project was so successful that the company has implemented more efficiency improvements that should result in energy cost savings of nearly $1 million per year.

Not Available

2005-01-01T23:59:59.000Z

379

Software Support during a Control Room Upgrade  

SciTech Connect

In 2004, after 14 years of accelerator operations and commissioning, Jefferson Lab renovated its main control room. Changes in technology and lessons learned during those 14 years drove the control room redesign in a new direction, one that optimizes workflow and makes critical information and controls available to everyone in the control room. Fundamental changes in a variety of software applications were required to facilitate the new operating paradigm. A critical component of the new control room design is a large-format video wall that is used to make a variety of operating information available to everyone in the room. Analog devices such as oscilloscopes and function generators are now displayed on the video wall through two crosspoint switchers: one for analog signals and another for video signals. A new software GUI replaces manual configuration of the oscilloscopes and function generators and helps automate setup. Monitoring screens, customized for the video wall, now make important operating information visible to everyone, not just a single operator. New alarm handler software gives any operator, on any workstation, access to all alarm handler functionality, and multiple users can now contribute to a single electronic logbook entry. To further support the shift to distributed access and control, many applications have been redesigned to run on servers instead of on individual workstations.

Michele Joyce; Michael Spata; Thomas Oren; Anthony Cuffe; Theo McGuckin; Isadoro Carlino; C. Higgins; Harry Fanning; Matthew Bickley; Brian Bevins

2005-09-21T23:59:59.000Z

380

Study of the effects of ambient conditions upon the performance of fan powdered, infrared, natural gas burners. Quarterly technical progress report, January 1, 1996--March 31, 1996  

DOE Green Energy (OSTI)

The objective of this investigation is to characterize the operation of fan powered infrared burner (PER) at various gas compositions and ambient conditions and develop design guidelines for appliances containing PER burners for satisfactory performance. During this past quarter, a porous radiant burner testing facility consisting of a commercial deep-fat fryer, an FTIR based spectral radiance measurement system, a set of flue gas analysis components, and a fuel gas mixing station was constructed. The measurement capabilities of the system were tested using methane and the test results were found to be consistent with the literature. Various gas mixtures were tested. Results indicated that the stability limits of the burner and emissions vary with fuel gas composition and air/fuel ratio. However, the maximum radiant efficiency of the burner remained constant. Results obtained from this study can be useful to develop optimum design guidelines for PER burner manufacturers.

Bai, T.; Yeboah, Y.D.; Sampath, R.

1996-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Method of remotely constructing a room  

DOE Patents (OSTI)

The testing of nuclear devices of high explosive yield has required that cavities of relatively large size be provided at considerable distances below the surface of the earth for the pre-detonation emplacement of the device. The construction of an essentially watertight chamber or room in the cavity is generally required for the actual emplacement of the device. A method is described of constructing such a room deep within the earth by personnel at the surface. A dual wall bladder of a watertight, pliable fabric material is lowered down a shaft into a selected position. The bladder is filled with a concrete grout while a heavy fluid having essentially the same density as the grout is maintained on both sides of the bladder, to facilitate complete deployment of the bladder by the grout to form a room of desired configuration. (10 claims)

Michie, J.D.; De Hart, R.C.

1971-10-05T23:59:59.000Z

382

Carbon War Room | Open Energy Information  

Open Energy Info (EERE)

War Room War Room Jump to: navigation, search Name Carbon War Room Place Washington, DC Number of employees 1-10 Website http://www.carbonwarroom.com/ Coordinates 38.8951118°, -77.0363658° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.8951118,"lon":-77.0363658,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

383

A New Control Room for SLAC Accelerators  

SciTech Connect

We are planning to construct a new control room at SLAC to unify and improve the operation of the LCLS, SPEAR3, and FACET accelerator facilities, and to provide the space and flexibility needed to support the LCLS-II and proposed new test beam facilities. The existing control rooms for the linac and SPEAR3 have been upgraded in various ways over the last decade, but their basic features have remained unchanged. We propose to build a larger modern Accelerator Control Room (ACR) in the new Research Support Building (RSB) which is currently under construction at SLAC. Shifting the center of control for the accelerator facilities entails both technical and administrative challenges. In this paper, we describe the history, concept, and status of this project.

Erickson, Roger; Guerra, E.; Stanek, M.; Hoover, Z.Van; Warren, J.; /SLAC

2012-06-04T23:59:59.000Z

384

TRANSIENT ACCIDENT ANALYSIS OF THE GLOVEBOX SYSTEM IN A LARGE PROCESS ROOM  

DOE Green Energy (OSTI)

Local transient hydrogen concentrations were evaluated inside a large process room when the hydrogen gas was released by three postulated accident scenarios associated with the process tank leakage and fire leading to a loss of gas confinement. The three cases considered in this work were fire in a room, loss of confinement from a process tank, and loss of confinement coupled with fire event. Based on these accident scenarios in a large and unventilated process room, the modeling calculations of the hydrogen migration were performed to estimate local transient concentrations of hydrogen due to the sudden leakage and release from a glovebox system associated with the process tank. The modeling domain represented the major features of the process room including the principal release or leakage source of gas storage system. The model was benchmarked against the literature results for key phenomena such as natural convection, turbulent behavior, gas mixing due to jet entrainment, and radiation cooling because these phenomena are closely related to the gas driving mechanisms within a large air space of the process room. The modeling results showed that at the corner of the process room, the gas concentrations migrated by the Case 2 and Case 3 scenarios reached the set-point value of high activity alarm in about 13 seconds, while the Case 1 scenario takes about 90 seconds to reach the concentration. The modeling results were used to estimate transient radioactive gas migrations in an enclosed process room installed with high activity alarm monitor when the postulated leakage scenarios are initiated without room ventilation.

Lee, S

2008-01-11T23:59:59.000Z

385

Study on Water-Cooled Solar Semiconductor Air Conditioner  

Science Conference Proceedings (OSTI)

Water-cooled solar semiconductor air conditioner was designed. Relevant calculation was made to determine the room's cooling load, which export the solar panels and battery capacity, followed by selection of CNC matcher. Development work also involves ... Keywords: solar energy, peltier effect, semiconductor air conditioner

Dong Zhi-Ming; Chang Ji-Bin; Xiang Li-Juan; Zhou Xue-Bin

2012-04-01T23:59:59.000Z

386

Software Verification and Validation Test Report for the HEPA filter Differential Pressure Fan Interlock System  

Science Conference Proceedings (OSTI)

The HEPA Filter Differential Pressure Fan Interlock System PLC ladder logic software was tested using a Software Verification and Validation (V&V) Test Plan as required by the ''Computer Software Quality Assurance Requirements''. The purpose of his document is to report on the results of the software qualification.

ERMI, A.M.

2000-09-05T23:59:59.000Z

387

Automated Aspect Recommendation through Clustering-Based Fan-in Analysis  

Science Conference Proceedings (OSTI)

Identifying code implementing a crosscutting concern (CCC) automatically can benefit the maintainability and evolvability of the application. Although many approaches have been proposed to identify potential aspects, a lot of manual work is typically ... Keywords: ranking metric, automated aspect recommendation, clustering-based fan-in analysis, crosscutting concern, refactorable aspects, aspect mining, method clusters, lexical based clustering

Danfeng Zhang; Yao Guo; Xiangqun Chen

2008-09-01T23:59:59.000Z

388

Imbalance of CPU temperatures in a blade system and its impact for power consumption of fans  

Science Conference Proceedings (OSTI)

We are now developing a new metric of data center power efficiency to fairly evaluate the contribution of each improvement for power efficiency. In order to develop it, we built a testbed of a data center and measured power consumption of each components ... Keywords: CPU temperature, Data center, Fan speed, Power consumption, Power efficiency

Yuetsu Kodama; Satoshi Itoh; Toshiyuki Shimizu; Satoshi Sekiguchi; Hiroshi Nakamura; Naohiko Mori

2013-03-01T23:59:59.000Z

389

Experimental Modal Analysis on a Rotating Fan Using Tracking-CSLDV  

Science Conference Proceedings (OSTI)

Continuous Scan Laser Doppler Vibrometry (CSLDV) modifies the traditional mode of operation of a vibrometer by sweeping the laser measurement point continuously over the structure while measuring, enabling one to measure spatially detailed mode shapes quickly and minimizing the inconsistencies that can arise if the structure or test conditions change with time. When a periodic scan path is employed, one can decompose the measurement into the response that would have been measured at each point traversed by the laser and obtain the structure's mode shapes and natural frequencies using conventional modal analysis software. In this paper, continuous-scan vibrometry is performed on a rotating fan, using computer controlled mirrors to track the rotating fan blades while simultaneously sweeping the measurement point over the blades. This has the potential to circumvent the difficulty of attaching contact sensors such as strain gauges, which might modify the structure and invalidate the results. In this work, impact excitation was used to excite a 3-blade fan rotating at various speeds, and the blades were scanned with a cloverleaf pattern that captured the bending of all three blades simultaneously. Some specialized signal processing is helpful in minimizing the effect of rotation frequency harmonics in the measurements, and specific scan strategies are needed to avoid those frequencies, both of these issues are discussed in the paper. While noise in the laser vibrometer does pose some difficulty, the results show that several modes could be extracted and that the tracking-CSLDV results agree with measurements obtained from the parked fan.

Gasparoni, Andrea; Castellini, Paolo; Tomasini, Enrico P. [Dipartimento di Meccanica, Universita Politecnica delle Marche, Via Brecce Bianche, 60131 Ancona (Italy); Allen, Matthew S.; Yang Shifei; Sracic, Michael W. [Department of Engineering Physics, University of Wisconsin-Madison, 535 Engineering Research Building, 1500 Engineering Drive, Madison, WI 53706 (United States)

2010-05-28T23:59:59.000Z

390

Evaluation of ASD Systems for Electric Arc Furnace and Argon Oxygen Decarburization Refiner Baghouse Fans  

Science Conference Proceedings (OSTI)

An adjustable speed drive (ASD) offers opportunities to operate dust collection fans in a more energy efficient manner. This report focuses on the system requirements and provides a method for successfully applying ASDs to dust extraction baghouse systems in a steel melting and refining application in order to realize full energy savings and operational improvements.

1998-01-23T23:59:59.000Z

391

Engineering Task Plan for Hepa Filter Differential Pressure (DP) Fan Interlock Upgrades  

SciTech Connect

This document provides a plan for installation of Differential Pressure (DP) fan interlocks on the primary ventilation systems in selected Tank Farm facilities. This plan contains the engineering tasks required for installation and is summarized by the Acceptance for Beneficial Use list. Individuals responsible for each task are identified and scheduled accordingly.

SIMONS, S.R.

2000-05-19T23:59:59.000Z

392

Fan to parallel beam conversion in CAT by rubber sheet transformation  

SciTech Connect

A technique for converting fan-beam projections to parallel-beam projections for use in computed tomography is presented. The problem is approached by use of a rubber sheet transformation. Since the data is discretized, an interpolation step is necessary. For densely sampled data this approach appears satisfactory and a significant reduction in photon noise is observable in computer simulations.

Wecksung, G.W.; Kruger, R.P.; Morris, R.A.

1979-01-01T23:59:59.000Z

393

Effect of a Radiant Panel Cooling System on Indoor Air Quality of a Conditioned Space  

E-Print Network (OSTI)

This paper discusses the effect of a radiant cooling panel system on an indoor air quality (IAQ) of a conditioned space. In this study, ceiling radiant cooling panel, mechanical ventilation with fan coil unit (FCU) and 100% fresh air are used. Temperature sensors are located at different locations inside the conditioned space in order to sense dry bulb temperatures, relative humidity to compare it with standard ASHRAE comfort values. The present investigation indicates that the radiant cooling system not only improves the indoor air quality but also reduces the building energy consumption in the conditioned space.

Mohamed, E.; Abdalla, K. N.

2010-01-01T23:59:59.000Z

394

Cold Air Distribution in Office Buildings: Technology Assessment for California  

E-Print Network (OSTI)

3) for different fan-powered mixing box designs and controloperating fan-powered mixing boxes in all of their designs.design, while still satisfying the building's cooling load. Consequently, fans and

Bauman, F.S.

2008-01-01T23:59:59.000Z

395

Reduce Air Infiltration in Furnaces (English/Chinese) (Fact Sheet)  

Science Conference Proceedings (OSTI)

Chinese translation of the Reduce Air Infiltration in Furnaces fact sheet. Provides suggestions on how to improve furnace energy efficiency. Fuel-fired furnaces discharge combustion products through a stack or a chimney. Hot furnace gases are less dense and more buoyant than ambient air, so they rise, creating a differential pressure between the top and the bottom of the furnace. This differential, known as thermal head, is the source of a natural draft or negative pressure in furnaces and boilers. A well-designed furnace (or boiler) is built to avoid air leakage into the furnace or leakage of flue gases from the furnace to the ambient. However, with time, most furnaces develop cracks or openings around doors, joints, and hearth seals. These openings (leaks) usually appear small compared with the overall dimensions of the furnace, so they are often ignored. The negative pressure created by the natural draft (or use of an induced-draft fan) in a furnace draws cold air through the openings (leaks) and into the furnace. The cold air becomes heated to the furnace exhaust gas temperature and then exits through the flue system, wasting valuable fuel. It might also cause excessive oxidation of metals or other materials in the furnaces. The heat loss due to cold air leakage resulting from the natural draft can be estimated if you know four major parameters: (1) The furnace or flue gas temperature; (2) The vertical distance H between the opening (leak) and the point where the exhaust gases leave the furnace and its flue system (if the leak is along a vertical surface, H will be an average value); (3) The area of the leak, in square inches; and (4) The amount of operating time the furnace spends at negative pressure. Secondary parameters that affect the amount of air leakage include these: (1) The furnace firing rate; (2) The flue gas velocity through the stack or the stack cross-section area; (3) The burner operating conditions (e.g., excess air, combustion air temperature, and so on). For furnaces or boilers using an induced-draft (ID) fan, the furnace negative pressure depends on the fan performance and frictional losses between the fan inlet and the point of air leakage. In most cases, it would be necessary to measure or estimate negative pressure at the opening. The amount of air leakage, the heat lost in flue gases, and their effects on increased furnace or boiler fuel consumption can be calculated by using the equations and graphs given in Industrial Furnaces (see W. Trinks et al., below). Note that the actual heat input required to compensate for the heat loss in flue gases due to air leakage would be greater than the heat contained in the air leakage because of the effect of available heat in the furnace. For a high-temperature furnace that is not maintained properly, the fuel consumption increase due to air leakage can be as high as 10% of the fuel input.

Not Available

2011-10-01T23:59:59.000Z

396

Thermostat response and room temperature control  

Science Conference Proceedings (OSTI)

This article examines the impact to thermal comfort of the operation of the room thermostat. The topics of the article include types of thermostat response, reset response, proportional response, digital systems, system response, verification of building temperatures, thermal comfort analysis, and productivity costs of implementing mandated setpoints.

Int-Hout, D. (Carrier Corp., Syracuse, NY (United States))

1994-01-01T23:59:59.000Z

397

Texas Union Pizza Order Form ROOM RESERVED ______________________________________________________  

E-Print Network (OSTI)

#12;#12;Texas Union Pizza Order Form ROOM RESERVED: ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ ________________________________________________________________________________________________ Pick-up All orders are to be picked up at the Texas Union Hospitality Center desk in the south end West with the Texas Union Policies and Procedures. I understand that I will be held responsible for any debts incurred

Texas at Austin, University of

398

Advanced nuclear plant control room complex  

DOE Patents (OSTI)

An advanced control room complex for a nuclear power plant, including a discrete indicator and alarm system (72) which is nuclear qualified for rapid response to changes in plant parameters and a component control system (64) which together provide a discrete monitoring and control capability at a panel (14-22, 26, 28) in the control room (10). A separate data processing system (70), which need not be nuclear qualified, provides integrated and overview information to the control room and to each panel, through CRTs (84) and a large, overhead integrated process status overview board (24). The discrete indicator and alarm system (72) and the data processing system (70) receive inputs from common plant sensors and validate the sensor outputs to arrive at a representative value of the parameter for use by the operator during both normal and accident conditions, thereby avoiding the need for him to assimilate data from each sensor individually. The integrated process status board (24) is at the apex of an information hierarchy that extends through four levels and provides access at each panel to the full display hierarchy. The control room panels are preferably of a modular construction, permitting the definition of inputs and outputs, the man machine interface, and the plant specific algorithms, to proceed in parallel with the fabrication of the panels, the installation of the equipment and the generic testing thereof.

Scarola, Kenneth (Windsor, CT); Jamison, David S. (Windsor, CT); Manazir, Richard M. (North Canton, CT); Rescorl, Robert L. (Vernon, CT); Harmon, Daryl L. (Enfield, CT)

1993-01-01T23:59:59.000Z

399

Operating Room Pooling and Parallel Surgery Processing Under Uncertainty  

Science Conference Proceedings (OSTI)

Operating room (OR) scheduling is an important operational problem for most hospitals. In this study, we present a novel two-stage stochastic mixed-integer programming model to minimize total expected operating cost given that scheduling decisions are ... Keywords: multiple operating rooms, operating room pooling, operating room scheduling, parallel surgery processing, two-stage stochastic mixed-integer programs

Sakine Batun; Brian T. Denton; Todd R. Huschka; Andrew J. Schaefer

2011-04-01T23:59:59.000Z

400

Thermal decay in underfloor air distribution (UFAD) systems: Fundamentals and influence on system performance  

E-Print Network (OSTI)

supply temperature AHU fan design static pressure AHU fanshown in Table 1, AHU fan design static pressure for series

Lee, Kwang Ho; Schiavon, Stefano; Bauman, Fred; Webster, Tom

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Evaluation of Indoor Air Quality Parameters and Airborne Fungal Spore Concentrations by Season and Type of HVAC System in a School Building.  

E-Print Network (OSTI)

??An indoor air quality survey has been conducted in a school building. Samples were collected inone room in each wing and each level on a (more)

McLeod, Jeffrey D.

2008-01-01T23:59:59.000Z

402

Air Resources: Prevention and Control of Air Contamination and Air  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Resources: Prevention and Control of Air Contamination and Air Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) < Back Eligibility Agricultural Fuel Distributor Industrial Institutional Investor-Owned Utility Local Government Multi-Family Residential Municipal/Public Utility Nonprofit Rural Electric Cooperative Schools State/Provincial Govt Transportation Tribal Government Utility Program Info State New York Program Type Environmental Regulations Provider NY Department of Environmental Conservation These regulations establish emissions limits and permitting and operational

403

Analysis of U.S. residential air leakage database  

SciTech Connect

The air leakage of a building envelope can be determined from fan pressurization measurements with a blower door. More than 70,000 air leakage measurements have been compiled into a database. In addition to air leakage, the database includes other important characteristics of the dwellings tested, such as floor area, year built, and location. There are also data for some houses on the presence of heating ducts, and floor/basement construction type. The purpose of this work is to identify house characteristics that can be used to predict air leakage. We found that the distribution of leakage normalized with floor area of the house is roughly lognormal. Year built and floor area are the two most significant factors to consider when predicting air leakage: older and smaller houses tend to have higher normalized leakage areas compared to newer and larger ones. Results from multiple linear regression of normalized leakage with respect to these two factors are presented for three types of houses: low-income, energy-efficient, and conventional. We demonstrate a method of using the regression model in conjunction with housing characteristics published by the US Census Bureau to derive a distribution that describes the air leakage of the single-family detached housing stock. Comparison of our estimates with published datasets of air exchange rates suggests that the regression model generates accurate estimates of air leakage distribution.

Chan, Wanyu R.; Price, Phillip N.; Sohn, Michael D.; Gadgil, Ashok J.

2003-07-01T23:59:59.000Z

404

2001: An Airspace Odyssey SUMMARY PROCEEDINGS OF THE 2001 AIRPORT NOISE SYMPOSIUM AND AIRPORT AIR QUALITY SYMPOSIUM  

E-Print Network (OSTI)

the use of advanced fan blade design and low noise fan exitreduce compressor fan noise, and the design of the nacelle

Gosling, Geoffrey D.

2001-01-01T23:59:59.000Z

405

Priority coding for control room alarms  

SciTech Connect

Indicating the priority of a spatially fixed, activated alarm tile on an alarm tile array by a shape coding at the tile, and preferably using the same shape coding wherever the same alarm condition is indicated elsewhere in the control room. The status of an alarm tile can change automatically or by operator acknowledgement, but tones and/or flashing cues continue to provide status information to the operator.

Scarola, Kenneth (Windsor, CT); Jamison, David S. (Windsor, CT); Manazir, Richard M. (North Canton, CT); Rescorl, Robert L. (Vernon, CT); Harmon, Daryl L. (Enfield, CT)

1994-01-01T23:59:59.000Z

406

Memorandum Memorializing Ex Parte Communication, DOE impending determination of coverage for commercial and industrial fans, blowers, and fume hoods.  

Energy.gov (U.S. Department of Energy (DOE))

The meeting was requested by AMCA International to introduce the associations leadership, standards, and experience in developing fan standards to DOE; to learn more about the DOE process for...

407

Science on Saturday attracts science fans of all ages | Princeton Plasma  

NLE Websites -- All DOE Office Websites (Extended Search)

Science on Saturday attracts science fans of all ages Science on Saturday attracts science fans of all ages By Jeanne Jackson DeVoe January 28, 2013 Tweet Widget Facebook Like Google Plus One Joshua E. G. Peek, a Hubble Fellow at Columbia University's Department of Astronomy and son of PPPL physicist and former director Robert Goldston, discusses "Outer Space!" (Photo by Elle Starkman/PPPL Office of Communications) Joshua E. G. Peek, a Hubble Fellow at Columbia University's Department of Astronomy and son of PPPL physicist and former director Robert Goldston, discusses "Outer Space!" Gallery: High school senior Varuni Bewtra comes to the lectures to learn about possible careers in science. (Photo by Photo by Jeanne Jackson DeVoe/PPPL Office of Communications) High school senior Varuni Bewtra comes to the lectures to learn about

408

Architectural characteristics of fine-grained submarine fans: A model applicable to the Gulf of Mexico  

Science Conference Proceedings (OSTI)

Submarine fan deposits in the Gulf of Mexico, modern and ancient, fall in the category of fine-grained, low overall sand/shale ratio basin-floor fans. Models published over the years that have been applied to both exploration and production are based on sand-rich fans, most of which were deposited in active margin settings. These models should not be used for the Gulf of Mexico or any other deep water system with similar basinal settings. Observations from the excellent outcrops of the Permian Tanqua Karoo in southwestern South Africa, together with information from the modern Mississippi Fan, and the Jackfork turbidites in Arkansas, enable the construction of a model that addresses the architecture of both the macro and meso-scale depositional features of fine-grained turbidite systems. At the entrance to the basin floor the conduit, carved out across the slope, may start to widen. Most of the density flows moving through do not necessarily occupy the conduit`s entire width. The result is a complex of laterally and vertically stacked channel fills and associated levee-overbank deposits with a good degree of connectivity. The channel fills are mostly massive, whereas the levee deposits are low-contrast, low-resistivity thin-bedded sandstones and shales with high permeability. Such sandstones can be potentially very productive. The channels gradually become smaller and as their influence on directing the heads of turbidity currents decreases, oblong sheet sands are deposited, each having a very large width to thickness ratio and a high sand/shale ratio. The vertical stacking patterns within these sheet sands commonly display lateral offset of individual beds or groups of beds, and therefore form a distinct reservoir type with varying internal fluid-flow characteristics.

Bouma, A.H.; Coleman, J.H. [Louisiana State Univ., Baton Rouge, LA (United States); DeV Wickens, H. [and others

1995-10-01T23:59:59.000Z

409

Standard practice for examination of fiberglass reinforced plastic fan blades using acoustic emission  

E-Print Network (OSTI)

1.1 This practice provides guidelines for acoustic emission (AE) examinations of fiberglass reinforced plastic (FRP) fan blades of the type used in industrial cooling towers and heat exchangers. 1.2 This practice uses simulated service loading to determine structural integrity. 1.3 This practice will detect sources of acoustic emission in areas of sensor coverage that are stressed during the course of the examination. 1.4 This practice applies to examinations of new and in-service fan blades. 1.5 This practice is limited to fan blades of FRP construction, with length (hub centerline to tip) of less than 3 m [10 ft], and with fiberglass content greater than 15 % by weight. 1.6 AE measurements are used to detect emission sources. Other nondestructive examination (NDE) methods may be used to evaluate the significance of AE sources. Procedures for other NDE methods are beyond the scope of this practice. 1.7 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as sta...

American Society for Testing and Materials. Philadelphia

2010-01-01T23:59:59.000Z

410

Random fan-out state induced by site-random interlayer couplings  

Science Conference Proceedings (OSTI)

We study the low-temperature properties of a classical Heisenberg model with site-random interlayer couplings on the cubic lattice. This model is introduced as a simplified effective model of Sr(Fe{sub 1-x}Mn{sub x})O{sub 2}, which was recently synthesized. In this material, when x=0.3, ({pi}{pi}{pi}) and ({pi}{pi}0) mixed ordering is observed by neutron diffraction measurements. Using Monte Carlo simulations, we find an exotic bulk spin structure that explains the experimentally obtained results. We name this spin structure the ''random fan-out state.'' The mean-field calculations provide an intuitive understanding of this phase being induced by the site-random interlayer couplings. Since Rietveld analysis assuming the random fan-out state agrees well with the neutron diffraction pattern of Sr(Fe{sub 0.7}Mn{sub 0.3})O{sub 2}, we conclude that the random fan-out state is reasonable for the spin-ordering pattern of Sr(Fe{sub 0.7}Mn{sub 0.3})O{sub 2} at the low-temperature phase.

Tamura, Ryo; Kawashima, Naoki; Yamamoto, Takafumi; Tassel, Cedric; Kageyama, Hiroshi [Institute for Solid State Physics, University of Tokyo, 5-1-5 Kashiwa-no-ha, Kashiwa, Chiba 277-8581 (Japan); Department of Energy and Hydrocarbon Chemistry, Graduate School of Engineering, Kyoto University, Nishikyouku, Kyoto 615-8510 (Japan)

2011-12-01T23:59:59.000Z

411

Air Distribution Systems and Cross-Infection Risk in the Hospital Sector  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Distribution Systems and Cross-Infection Risk in the Hospital Sector Air Distribution Systems and Cross-Infection Risk in the Hospital Sector Speaker(s): Peter V. Nielsen Date: November 28, 2012 - 12:00pm Location: 90-4133 Seminar Host/Point of Contact: Rongxin Yin We protect ourselves from airborne cross-infection in the indoor environment by supplying fresh air to the room by natural or mechanical ventilation. The air is distributed in the room according to different principles as e.g. mixing ventilation, downward ventilation, displacement ventilation, etc. A large amount of air is supplied to the room to ensure dilution of airborne infection. The talk discusses both the macroenvironment and the microenvironment. The macroenvironment is the conditions created by the air distribution system, and the microenvironment is the conditions created by the local flow around persons in combination

412

Economic Recovery of Oil Trapped at Fan Margins Using Hig Angle Wells Multiple Hydraulic Fractures  

Science Conference Proceedings (OSTI)

The Yowlumne field is a giant field in the southern San Joaquin basin, Kern County, California. It is a deep (13,000 ft) waterflood operation that produces from the Miocene- aged Stevens Sand. The reservoir is interpreted as a layered, fan-shaped, prograding turbidite complex containing several lobe-shaped sand bodies that represent distinct flow units. A high ultimate recovery factor is expected, yet significant quantities of undrained oil remain at the fan margins. The fan margins are not economic to develop using vertical wells because of thinning pay, deteriorating rock quality, and depth. This project attempts to demonstrate the effectiveness of exploiting the northeast distal fan margin through the use of a high- angle well completed with multiple hydraulic- fracture treatments. A high-angle well offers greater pay exposure than can be achieved with a vertical well. Hydraulic-fracture treatments will establish vertical communication between thin interbedded layers and the wellbore. The equivalent production rate and reserves of three vertical wells are anticipated at a cost of approximately two vertical wells. The near-horizontal well penetrated the Yowlumne sand; a Stevens sand equivalent, in the distal fan margin in the northeast area of the field. The well was drilled in a predominately westerly direction towards the interior of the field, in the direction of improving rock quality. Drilling and completion operations proved to be very challenging, leading to a number of adjustments to original plans. Hole conditions resulted in obtaining less core material than desired and setting intermediate casing 1200 ft too high. The 7 in. production liner stuck 1000 ft off bottom, requiring a 5 in. liner to be run the rest of the way. The cement job on the 5 in. liner resulted in a very poor bond, which precluded one of three hydraulic fracture treatments originally planned for the well. Openhole logs confirmed most expectations going into the project about basic rock properties: the formation was shaly with low porosities, and water saturations were in line with expectations, including the presence of some intervals swept out by the waterflood. High water saturations at the bottom of the well eliminated one of the originally planned hydraulic fracture treatments. Although porosities proved to be low, they were more uniform across the formation than expected. Permeabilities of the various intervals continue to be evaluated, but appear to be better than expected from the porosity log model derived in Budget Period One. The well was perforated in all pay sections behind the 5 in. liner. Production rates and phases agree nicely with log calculations, fractional flow calculations, and an analytical technique used to predict the rate performance of the well.

Laue, M.L.

1997-11-21T23:59:59.000Z

413

High-amplitude reflection packets (HARPs) of the Mississippi Fan, Gulf of Mexico  

E-Print Network (OSTI)

Examination of seismic data from the deep-water Gulf of Mexico reveals the presence of High-Amplitude Reflection Packets (HARPs). An analog study conducted by the Ocean Drilling Program Leg 155 identified and described Amazon Fan HARPs as a stacked, relatively unconfined series of graded turbidites overlain by a channel-levee. HARP seismic facies thin laterally and onlap antecedent bathymetry (preexisting submarine topography). HARP areal extent is controlled by antecedent bathymetry and turbidity flow sediment volumes. Mississippi Fan HARP deposition can be described by three depositional models: the "avulsion" model, the "fill and spill" model, and the "transition" model. The "avulsion" depositional model, developed by Flood et al. (1991), describes avulsion of submarine channel-levees by turbidity flows. Subsequent turbidity flows exit the channel-levee at the avulsion point and are deposited as unchannelized HARPs. The "fill and spill" model, developed by Satterfield and Behrens (1990), describes turbidite deposition in the Gulf of Mexico salt province. Initial stages of the "fill and spill" model accurately describe the seismic geometries of HARPs confined by adjacent salt structures. The "transition" model was developed in this study to describe the Gulf of Mexico HARP seismic geometries seen in the transition zone from the salt province to the abyssal plain. The HARPs described by the "transition" model contain an upslope segment confined by salt structures and a downslope segment confined by antecedent bathymetry. Utilizing seismic data from the Gulf of Mexico and core and well-log data from the Amazon Fan, this study has determined that HARPs and related channel-levees have hydrocarbon play potential. HARP sheet sands, internal HARP channel fill, overlying channel-levee fill, and overbank levee sands are potential reservoir units. Detrital carbonate and hemipelagic shale source rocks are in place in the deep-water Gulf of Mexico. In addition, structurally derived migration pathways combine with percolation as potential migration processes. This study integrates identification and description of HARP seismic facies relationships, current and newly developed depositional models, interpretation of stratigraphic controls, HARP internal reservoir architecture, and determination of HARP hydrocarbon potential in order to predict HARP deposition in the Mississippi Fan and other mud-rich fans worldwide.

Francis, Jason Michael

2000-01-01T23:59:59.000Z

414

Release of DRAFT RFP Headquarters Reading Room Instructions/Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

Release of DRAFT RFP Release of DRAFT RFP Headquarters Reading Room Instructions/Guidelines 1. Reading Room Points of Contact: 7/21 - 8/8, Mike Baehre, (202) 586-6575 8/9 - Close of Draft RFP, John Bernier, (202) 586-6416 Reading Room Availability: By Appointment - Reading Room will be available until DRAFT RFP Closes. Reading Room Hours: Morning, 9:00 a.m. - 11:30 a.m.; and Afternoon 1:00 p.m. - 3:30 p.m. Reading Room Will Accommodate: Up to 5-6 people 2. All personnel must: a. Sign-in b. Identify their Company or Firm they work for or are affiliated c. Indicate if they have a "Q" clearance 3. Personnel must stay in the Reading Room to view documents. The "A" corridor is inside a classified area and all visitors to the Reading Room must be escorted at all times.

415

Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration  

E-Print Network (OSTI)

terrain class (1-5)[dflt=3J";TCL 'Input terrain class atsite. IF TCL=0 THEN TCL=3 INPUT "Are you going to use wind data froM the

Grimsrud, David T.

2009-01-01T23:59:59.000Z

416

Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration  

E-Print Network (OSTI)

unvented combustion was Wood combustion present in housescombustion engines are a major source of the outdoor concentrations observed while wood,

Grimsrud, David T.

2009-01-01T23:59:59.000Z

417

Field Study of Exhaust Fans for Mitigating Indoor Air Quality Problems: Final Report to Bonneville Power Administration  

E-Print Network (OSTI)

to mount the passive samplers in a house. designed describedhouses screened for study List of Figures A.l A.2 A.3 A.4 PassivePassive Sampler Sampler Girman/Allen Girman/Allen Wednesday 16 November Test house (

Grimsrud, David T.

2009-01-01T23:59:59.000Z

418

Sorption of organic gases in a furnished room  

SciTech Connect

We present experimental data and semi-empirical models describing the sorption of organic gases in a simulated indoor residential environment. Two replicate experiments were conducted with 20 volatile organic compounds (VOCs) in a 50-m{sup 3} room finished with painted wallboard, carpet and cushion, draperies and furnishings. The VOCs span a wide volatility range and include ten Hazardous Air Pollutants. VOCs were introduced to the static chamber as a pulse and their gas-phase concentrations were measured during a net adsorption period and a subsequent net desorption period. Three sorption models were fit to the measured concentrations for each compound to determine the simplest formulation needed to adequately describe the observed behavior. Sorption parameter values were determined by fitting the models to adsorption period data then checked by comparing measured and predicted behavior during desorption. The adequacy of each model was evaluated using a goodness of fit parameter calculated for each period. Results indicate that sorption usually does not greatly affect indoor concentrations of methyl-tert-butyl ether, 2-butanone, isoprene and benzene. In contrast, sorption appears to be a relevant indoor process for many of the VOCs studied, including C{sub 8}-C{sub 10} aromatic hydrocarbons (HC), terpenes, and pyridine. These compounds sorbed at rates close to typical residential air change rates and exhibited substantial sorptive partitioning at equilibrium. Polycyclic aromatic HCs, aromatic alcohols, ethenylpyridine and nicotine initially adsorbed to surfaces at rates of 1.5 to >6 h{sup -1} and partitioned 95 to >99% in the sorbed phase at equilibrium.

Singer, Brett C.; Revzan, Kenneth L.; Hotchi, Toshifumi; Hodgson, Alfred T.; Brown, Nancy J.

2003-11-30T23:59:59.000Z

419

Vehicle cabin cooling system for capturing and exhausting heated boundary layer air from inner surfaces of solar heated windows  

DOE Patents (OSTI)

The cabin cooling system includes a cooling duct positioned proximate and above upper edges of one or more windows of a vehicle to exhaust hot air as the air is heated by inner surfaces of the windows and forms thin boundary layers of heated air adjacent the heated windows. The cabin cooling system includes at least one fan to draw the hot air into the cooling duct at a flow rate that captures the hot air in the boundary layer without capturing a significant portion of the cooler cabin interior air and to discharge the hot air at a point outside the vehicle cabin, such as the vehicle trunk. In a preferred embodiment, the cooling duct has a cross-sectional area that gradually increases from a distal point to a proximal point to the fan inlet to develop a substantially uniform pressure drop along the length of the cooling duct. Correspondingly, this cross-sectional configuration develops a uniform suction pressure and uniform flow rate at the upper edge of the window to capture the hot air in the boundary layer adjacent each window.

Farrington, Robert B. (Golden, CO); Anderson, Ren (Broomfield, CO)

2001-01-01T23:59:59.000Z

420

Pre-validation of nuclear power plant control room design  

Science Conference Proceedings (OSTI)

Evaluation of the design of complex automation and control room systems is an essential phase in the design process in the nuclear field. For example, in order to meet the nuclear regulatory requirements, the new control room systems have to be evaluated ... Keywords: concept of operations, control room, pre-validation, verification & validation

Jari Laarni; Paula Savioja; Hannu Karvonen; Leena Norros

2011-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Innovative Systems for Solar Air Conditioning of Buildings  

E-Print Network (OSTI)

Solar air conditioning is an attractive technology to achieve comfortable room conditions, especially in hot and sunny climates. In particular air conditioning systems based on sorption technologies offer several advantages as they can be designed for a high efficient utilization of solar thermal energy. To show the today's and near future potential innovative solar cooling and air conditioning systems are discussed which are well adapted to the utilization of solar energy. The system performance of each air conditioning system is evaluated under Abu Dhabi design conditions.

Kessling, W.; Peltzer, M.

2004-01-01T23:59:59.000Z

422

Air Pollution (Illinois)  

Energy.gov (U.S. Department of Energy (DOE))

This article states regulations for monitoring air pollution, methods for permit applications, emission limitations for pollutants and air quality standards.

423

Active Noise Control of a Two-Fan Exhaust-Mounted Array Using Near-Field Control Sources and Error Sensors.  

E-Print Network (OSTI)

??Multiple fans are sometimes used in an array configuration to cool various types of electronic equipment. In addition to adding another noise source, using two (more)

Rust, Ryan Leonard 1982-

2010-01-01T23:59:59.000Z

424

Reason and reaction: The dual route of decision making process on social media usage: The case of hospitality brand fan pages.  

E-Print Network (OSTI)

??A new phenomenon on Facebook, resulting from social media revolution, is the emergence of numerous Facebook fan pages. This form of online brand community is (more)

Manthiou, Aikaterini

2012-01-01T23:59:59.000Z

425

Solar assisted heat pump on air collectors: A simulation tool  

Science Conference Proceedings (OSTI)

The heating system of the bioclimatic building of the Greek National Centre for Renewable Energy Sources (CRES) comprises two heating plants: the first one includes an air source heat pump, Solar Air Collectors (SACs) and a heat distribution system (comprising a fan coil unit network); the second one is, mainly, a geothermal heat pump unit to cover the ground floor thermal needs. The SAC configuration as well as the fraction of the building heating load covered by the heating plant are assessed in two operation modes; the direct (hot air from the collectors is supplied directly to the heated space) and the indirect mode (warm air from the SAC or its mixture with ambient air is not supplied directly to the heated space but indirectly into the evaporator of the air source heat pump). The technique of the indirect mode of heating aims at maximizing the efficiency of the SAC, saving electrical power consumed by the compressor of the heat pump, and therefore, at optimizing the coefficient of performance (COP) of the heat pump due to the increased intake of ambient thermal energy by means of the SAC. Results are given for three research objectives: assessment of the heat pump efficiency whether in direct or indirect heating mode; Assessment of the overall heating plant efficiency on a daily or hourly basis; Assessment of the credibility of the suggested simulation model TSAGAIR by comparing its results with the TRNSYS ones. (author)

Karagiorgas, Michalis; Galatis, Kostas; Tsagouri, Manolis [Department of Mechanical Engineering Educators, ASPETE, N. Iraklio, GR 14121 (Greece); Tsoutsos, Theocharis [Environmental Engineering Dept., Technical University of Crete, Technical University Campus, GR 73100, Chania (Greece); Botzios-Valaskakis, Aristotelis [Centre for Renewable Energy Sources (CRES), 19th km Marathon Ave., GR 19001, Pikermi (Greece)

2010-01-15T23:59:59.000Z

426

NETL: NewsRoom - LabNotes  

NLE Websites -- All DOE Office Websites (Extended Search)

LabNotes LabNotes NewsRoom LabNotes January 2014 Chemical Looping 101: The Basics NETL's Chemical Looping Research Facilities Oxygen Carriers in Chemical Looping Combustion Chemical Looping Modeling and Simulation Research at NETL December 2013 Foamed Cement Can Seal Tricky Oil and Gas Wells November 2013 High-Performance Rechargeable Batteries May Help Keep the Lights On Rocks Demystified in Geomechanical Properties Lab October 2013 NETL's Morgantown Supercomputer Sets a High Bar for Energy Efficiency September 2013 NETL's Energy Data Exchange (EDX): Providing Access to Quality Energy Data Sorbents Capturing CO2 Will Make Power Plants Cleaner August 2013 Collaborative Technology Demonstrates Potential in Diabetes Testing Quantifying Uncertainty in Computer Model Predictions

427

Absorber Materials at Room and Cryogenic Temperatures  

Science Conference Proceedings (OSTI)

We recently reported on investigations of RF absorber materials at cryogenic temperatures conducted at Jefferson Laboratory (JLab). The work was initiated to find a replacement material for the 2 Kelvin low power waveguide Higher Order Mode (HOM) absorbers employed within the original cavity cryomodules of the Continuous Electron Beam Accelerator Facility (CEBAF). This effort eventually led to suitable candidates as reported in this paper. Furthermore, though constrained by small funds for labor and resources, we have analyzed a variety of lossy ceramic materials, several of which could be usable as HOM absorbers for both normal conducting and superconducting RF structures, e.g. as loads in cavity waveguides and beam tubes either at room or cryogenic temperatures and, depending on cooling measures, low to high operational power levels.

F. Marhauser, T.S. Elliott, A.T. Wu, E.P. Chojnacki, E. Savrun

2011-09-01T23:59:59.000Z

428

Strategy for the Operation of Cooling Towers with variable Speed Fans  

E-Print Network (OSTI)

Within the SPS Cooling Water Project at CERN aimed at the reduction of water consumption, this primary open cooling loop will be closed and all the primary cooling circuit components will be upgraded to the new required duty and brought to the necessary safety and operability standards. In particular the tower fans will be fitted with variable frequency drives to replace the existing two speed motors. This paper presents a study to optimize the operation of SPS cooling towers taking into account outdoor conditions (wet and dry bulb temperatures) and the entirety of the primary circuit in which they will operate.

Iigo-Golfn, J

2001-01-01T23:59:59.000Z

429

Busemann functions and the speed of a second class particle in the rarefaction fan  

E-Print Network (OSTI)

In this paper we will show how the results found in Cator and Pimentel 2009, about the Busemann functions in last-passage percolation, can be used to calculate the asymptotic distribution of the speed of a single second class particle starting from an arbitrary deterministic configuration which has a rarefaction fan, in either the totally asymetric exclusion process, or the Hammersley interacting particle process. The method will be to use the well known last-passage percolation description of the exclusion process and of the Hammersley process, and then the well known connection between second class particles and competition interfaces.

Eric Cator; Leandro P. R. Pimentel

2010-08-10T23:59:59.000Z

430

SMALL OIL BURNER CONCEPTS BASED ON LOW PRESSURE AIR ATOMIZATION  

DOE Green Energy (OSTI)

The development of several novel oil burner applications based on low pressure air atomization is described. The atomizer used is a prefilming, airblast nozzle of the type commonly used in gas turbine combustion. The air pressure used can be as low as 1,300 Pa and such pressure can be easily achieved with a fan. Advantages over conventional, pressure-atomized nozzles include ability to operate at low input rates without very small passages and much lower fuel pressure requirements. The development of three specific applications is presented. The first two are domestic heating burners covering a capacity range 10 to 26 kW. The third application presented involves the use of this burner in an oil-fired thermophotovoltaic power generator system. Here the design firing rate is 2.9 kW and the system produces 500 watts of electric power.

BUTCHER,T.; CELEBI,Y.; WEI,G.; KAMATH,B.

2000-03-16T23:59:59.000Z

431

Pressure Regain Strategies for Existing Air Distribution Systems  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Pressure Regain Strategies for Pressure Regain Strategies for Existing Air Distribution Systems Arlan Burdick IBACOS, Inc. Pressure Regain Strategies for Existing Air Distribution Systems Problem Statement Thermal enclosure upgrades can reduce peak loads by 50%. If the furnace is right-sized for this new peak load and the ducts are not modified or replaced, the resulting airflows at the supply registers will be significantly reduced. -Will the outlets meet industry standards for performance? - Should they be replaced to achieve good room air mixing? - Should the end of the duct be modified to improve airflow characteristics? Pressure Regain Strategies for Existing Air Distribution Systems Expected Results We expect to find a cost-effective solution to gaining proper airflow to a room without completely replacing

432

SCE - Residential Energy Efficiency Rebate Program | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Freezer Recycling: 35 Electric Water Heater: 30 Room Air Conditioner: 20 Whole House Fan: 50 Evaporative Cooler: 300 Summer AC Cycling: 100-200 Pool Pump and Motor: 200...

433

Air Leakage of Furnaces and Air Handlers  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Leakage of Furnaces and Air Handlers Air Leakage of Furnaces and Air Handlers Title Air Leakage of Furnaces and Air Handlers Publication Type Journal Article LBNL Report Number LBNL-5553E Year of Publication 2010 Authors Walker, Iain S., Mile Lubliner, Darryl J. Dickerhoff, and William W. Delp Journal 2010 ACEEE Summer Study on Energy Efficiency in Buildings The Climate for efficiency is now Date Published 08/2010 Abstract In recent years, great strides have been made in reducing air leakage in residential and to a lesser extent small commercial forced air duct systems. Several authorities have introduced low leakage limits for thermal distribution systems; for example, the State of California Energy Code for Buildings gives credit for systems that leak less than 6% of the total air flow at 25 Pa.

434

FANS - Principle  

Science Conference Proceedings (OSTI)

... detecting all scattered neutrons with energy Ef energies, with moderate ... which changes to optimize intensity during the ...

435

FANS - Overview  

Science Conference Proceedings (OSTI)

... Pyrolytic Graphite [PG(002)], Without small shield: 2.5 meV ? E ? 25.0 meV With small shield: 3.7 meV ? E ? 45.0 meV. ...

436

Prediction of Air Mixing From High Sidewall Diffusers in Cooling Mode: Preprint  

Science Conference Proceedings (OSTI)

Computational fluid dynamics modeling was used to evaluate the performance of high sidewall air supply in cooling mode. The research focused on the design, placement, and operation of air supply diffusers located high on a sidewall and return grilles located near the floor on the same sidewall. Parameters of the study are the supply velocity, supply temperature, diffuser dimensions and room dimensions. Thermal loads characteristic of high performance homes were applied at the walls and room temperature was controlled via a thermostat. The results are intended to provide information to guide the selection of high sidewall supply diffusers to provide proper room mixing for cooling of high performance homes.

Ridouane, E. H.; Gawlik, K.

2011-02-01T23:59:59.000Z

437

Metal-Air Batteries  

Science Conference Proceedings (OSTI)

Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

2011-08-01T23:59:59.000Z

438

Influence of provenance on detrital and diagenetic mineralogy of small tertiary fans in southwestern Montana  

SciTech Connect

In the North Boulder River basin in southwestern Montana, alluvial fans of the Renova (Oligocene-Miocene) and the Sixmile Creek (Miocene) Formations were deposited on the flanks of north-south-trending uplifts that also supplied the detritus. The Elkhorn Mountain volcanics (78 m.y.) overlying the Boulder batholith make up the western highlands, a small patch of Precambrian Belt Group rocks occur in the southwest and Paleozoic siliciclastic and carbonate rocks forming the eastern margin. The fan sediments thus allow adequate control for studying the influence of source rocks on detrital and diagenetic mineralogy. Modal analysis of 6228 grains in 31 thin sections shows a decrease of VRF away from the igneous sources (37% to 1% in a north-south transect; 37% to 7% in a west-east transect) along with an increase in quartz (8% to 24% and 3% to 13%) and plagioclase (2% to 16% and 2% to 10%); orthoclase abundance is low except in the southwest. Volcanic ash and glass shards are found in the younger sediments in the northern part of the basin. Their data show a positive correlation between the abundance of orthoclase and kaolinite (north-south transect); between SRF and carbonate cement (west-east transect) and between glass shards and smectite (both north-south and west-east transects). They infer that the diagenetic mineralogy of these sands was controlled essentially by the detrital particles, which were strongly controlled by source rocks in this area.

Olson, J.; Basu, A.

1987-05-01T23:59:59.000Z

439

Correlation efficiency as a tool to establish depositional subenvironments in submarine fans  

Science Conference Proceedings (OSTI)

Depositional units in submarine fan systems commonly are too large to be entirely or sufficiently exposed in an outcrop to properly identify. Channel fills can be massive, bedded, or any combination thereof. The layering can be horizontal or inclined. Typical bedded series can be thick or thin bedded, or a combination with or without a certain cyclicity. Occurrence of sedimentary structures is not yet a decisive interpretation characteristic. At the present, the Lower Permian Skoorsteenberg Formation of the Southwest Karoo in South Africa may be the best example of long, nontilted, outcrops where entire subenvironments can be observed. Using that knowledge, outcrop information from several areas, and ideas from the literature, we attempted correlations in two spillways in the Jackfork Group in Arkansas. A layer-by-layer correlation failed, even after small layer package could be established using an occasional thick shale break, a major slump, or a very thick massive sandstone layer for dividing both sides of the spillway. A [open quotes]semi-logarithmic[close quotes] display of measured thickness provides patterns of variations in layer thickness that normally are sufficiently typical to use as a correlation tool between both sides. This is not a foolproof system and one should consider additional parameters, such as location within the entire fan system. However, the degree of correlatibility helps identify or suggest depositional environments.

Bouma, A.H.; Cook, T.W. (Louisiana State Univ., Baton Rouge, LA (United States)); Devries, M.B. (Exxon Exploration Company, Houston, TX (United States))

1993-09-01T23:59:59.000Z

440

Electrorecovery of actinides at room temperature  

Science Conference Proceedings (OSTI)

There are a large number of purification and processing operations involving actinide species that rely on high-temperature molten salts as the solvent medium. One such application is the electrorefining of impure actinide metals to provide high purity material for subsequent applications. There are some drawbacks to the electrodeposition of actinides in molten salts including relatively low yields, lack of accurate potential control, maintaining efficiency in a highly corrosive environment, and failed runs. With these issues in mind we have been investigating the electrodeposition of actinide metals, mainly uranium, from room temperature ionic liquids (RTILs) and relatively high-boiling organic solvents. The RTILs we have focused on are comprised of 1,3-dialkylimidazolium or quaternary ammonium cations and mainly the {sup -}N(SO{sub 2}CF{sub 3}){sub 2} anion [bis(trif1uoromethylsulfonyl)imide {equivalent_to} {sup -}NTf{sub 2}]. These materials represent a class of solvents that possess great potential for use in applications employing electrochemical procedures. In order to ascertain the feasibility of using RTILs for bulk electrodeposition of actinide metals our research team has been exploring the electron transfer behavior of simple coordination complexes of uranium dissolved in the RTIL solutions. More recently we have begun some fundamental electrochemical studies on the behavior of uranium and plutonium complexes in the organic solvents N-methylpyrrolidone (NMP) and dimethylsulfoxide (DMSO). Our most recent results concerning electrodeposition will be presented in this account. The electrochemical behavior of U(IV) and U(III) species in RTILs and the relatively low vapor pressure solvents NMP and DMSO is described. These studies have been ongoing in our laboratory to uncover conditions that will lead to the successful bulk electrodeposition of actinide metals at a working electrode surface at room temperature or slightly elevated temperatures. The RTILs we have focused on thus far are based on 1,3-dialkylimidazolium or quaternary ammonium cations and {sup -}N(SO{sub 2}CF{sub 3}){sub 2} anions. Our results from XPS studies of e1ectrooxidized uranium metal surfaces indicate that uranium metal reacts with the anion from the RTIL, most likely through an initial f1uoride abstraction, forming decomposition products that inhibit the bulk electrodeposition of uranium metal. Similar results were found when the organic solvents were used with TBA[B(C{sub 6}F{sub 5}){sub 4}] as the supporting electrolyte, although the voltammetric data of uranium ions in these solutions is more encouraging in relation to electrodeposition of uranium metal. Preliminary results on the voltammetric behavior and bulk electrodeposition of plutonium species are also presented.

Stoll, Michael E [Los Alamos National Laboratory; Oldham, Warren J [Los Alamos National Laboratory; Costa, David A [Los Alamos National Laboratory

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Carbon promoted water electrolysis to produce hydrogen at room temperature.  

E-Print Network (OSTI)

??The objective of the work was to conduct water electrolysis at room temperature with reduced energy costs for hydrogen production. The electrochemical gasification of carbons (more)

Ranganathan, Sukanya.

2007-01-01T23:59:59.000Z

442

Building Energy Software Tools Directory: Cold Room Calc  

NLE Websites -- All DOE Office Websites (Extended Search)

skills helpful but not required. Users More than 200 around the world. Audience Cold room design engineers, refrigeration equipment suppliers and contractors, owners of...

443

Effect of building airtightness and fan size on the performance of mechanical ventilation systems in new U.S. houses: a critique of ASHRAE standard 62.2-2003  

E-Print Network (OSTI)

as sizing a fan to deliver the design ventilation rate (fans and natural infiltration, in order to properly designfans should be as small as necessary to deliver the effective design

Roberson, J.

2004-01-01T23:59:59.000Z

444

A holistic investigation of complexity sources in nuclear power plant control rooms  

E-Print Network (OSTI)

The nuclear power community in the United States is moving to modernize aging power plant control rooms as well as develop control rooms for new reactors. New generation control rooms, along with modernized control rooms, ...

Sasangohar, Farzan

2011-01-01T23:59:59.000Z

445

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

the current cost of production of 3.5 Rs per kWh. It isthe average cost of production to be 3.50 Rs. per kWh, or $the cost of production significantly at 4.80 Rs. per kWh. As

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

446

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

National Energy Consumption conditioner. National Energy Consumption When regulationsThe total energy consumption (NEC) of the national stock of

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

447

Technical and economic analysis of energy efficiency of Chinese room air conditioners  

E-Print Network (OSTI)

the impact on national energy consumption by adoption of thecase forecast of national energy consumption assumes thatcase forecast of national energy consumption assumes the

Fridley, David G.; Rosenquist, Gregory; Jiang, Lin; Li, Aixian; Xin, Dingguo; Cheng, Jianhong

2001-01-01T23:59:59.000Z

448

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

noted that reform of electricity tariff structures is a longin the residential electricity tariff structures. Each ofcosts, and prevailing electricity tariffs may have changed.

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

449

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

average. Rates collected by most State Electricity Boards inState Electricity Boards and Electricity Departments 2002- Discount Rates

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

450

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

because of the higher electricity rates, higher hours ofin use patterns and electricity rates between commercial andUEC), marginal electricity rates, and discount rates.

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

451

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

Electricity Prices Residential electricity rates are muchrates in India. Residential electricity rates are subsidizedand electricity rates between commercial and residential

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

452

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

L ABORATORY China Energy Efficiency Round Robin TestingNeed to Improve the Energy Efficiency of Energy Consumingfor Implementing the China Energy Efficiency Label System (

Zhou, Nan

2010-01-01T23:59:59.000Z

453

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

where the static pressure (ESP) is measured. The length oftaps used to measure the ESP may be in the same duct or inand the measurement of the ESP is performed in 4 points at

Zhou, Nan

2010-01-01T23:59:59.000Z

454

Effects of room furnishings and air speed on particle deposition rates indoors  

E-Print Network (OSTI)

^ of the National Nuclear Security Administration under U.S.of the National Nuclear Security Administration under U.S.

Thatcher, Tracy L.; Lai, Alvin C.K.; Moreno-Jackson, Rosa; Sextro, Richard G.; Nazaroff, William W.

2002-01-01T23:59:59.000Z

455

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

Table 5 Cost-Effectiveness of Energy Efficiency Commercial6 Cost-Effectiveness of Energy Efficiency ResidentialTable 5 Cost-Effectiveness of Energy Efficiency Commercial

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

456

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

labeling program (Energy Guide). In order to ensure thethe yellow label titled Energy Guide and has clearly sti-

Zhou, Nan

2010-01-01T23:59:59.000Z

457

Techno-Economic Analysis of Indian Draft Standard Levels for Room Air Conditioners  

E-Print Network (OSTI)

costs is adequately compensated by lower electricity bills.Electricity bill savings are in turn dependent on the hoursmargin, residential electricity bills do not cover utility

McNeil, Michael A.; Iyer, Maithili

2008-01-01T23:59:59.000Z

458

China Energy Efficiency Round Robin Testing Results for Room Air Conditioners  

E-Print Network (OSTI)

the market trend is increasingly towards energy efficiency.trend of trans- formation to an energy-efficient products market.

Zhou, Nan

2010-01-01T23:59:59.000Z

459

Feasibility of air capture  

E-Print Network (OSTI)

Capturing CO2 from air, referred to as Air Capture, is being proposed as a viable climate change mitigation technology. The two major benefits of air capture, reported in literature, are that it allows us to reduce the ...

Ranjan, Manya

2010-01-01T23:59:59.000Z

460

Analysis of the Window Side Thermal Environment Formed by Air Barrier Technique in Winter Conditions and Its Economy  

E-Print Network (OSTI)

The air barrier technique applies airflow through a window fan to decrease the heat load of a window surface and avoid dewfall in winter and decrease heat radiation from the window surface in summer. This paper uses numerical simulation to predict the energy-saving potential and thermal comfort of the air barrier technique used in office buildings. It also analyzes the surface temperature of the window by using the simulation software Airpak. According to the results, we can obtain the key control strategy of this technology. It can be found that the air barrier technique, instead of the heating-supply around outside-zone for office building, can avoid dewfall in winter and decrease the cold radiation, which has a great effect on thermal environment around the window. Characteristics such as outer air temperature, indoor load, thermal characteristics of structure, and air-supply parameters through window fans are analyzed in detail to measure their effects on energy consumption, window side environment and PMV values. The paper provides theoretical reference and technical guidance for applying air barrier technology correctly, improving the window side environment and reducing energy consumption.

Huang, C.; Jia, Y.; Liu, L.; Wang, X.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Primary zone air proportioner  

SciTech Connect

An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

Cleary, Edward N. G. (San Diego, CA)

1982-10-12T23:59:59.000Z

462

Air Pollution Control (Indiana)  

Energy.gov (U.S. Department of Energy (DOE))

This legislation establishes the Department of Environmental Management and the Air Pollution Control Board, which are tasked with the prevention, abatement, and control of air pollution by all...

463

Evaluation of Air Mixing and Thermal Comfort From High Sidewall Supply Air Jets  

SciTech Connect

Uniform mixing of conditioned air with room air is an essential factor for providing comfort in homes. The higher the supply flow rates the easier to reach good mixing in the space. In high performance homes, however, the flow rates required to meet the small remaining thermal loads are not large enough to maintain uniform mixing in the space. The objective of this study is to resolve this issue and maintain uniform temperatures within future homes. We used computational fluid dynamics modeling to evaluate the performance of high sidewall air supply for residential applications in heating and cooling modes. Parameters of the study are the supply velocity, supply temperature, diffuser dimensions, and room dimensions. Laboratory experiments supported the study of thermal mixing in heating mode; we used the results to develop a correlation to predict high sidewall diffuser performance. For cooling mode, numerical analysis is presented. The results provide information to guide the selection of high sidewall supply diffusers to maintain proper room mixing for heating and cooling of high performance homes. It is proven that these systems can achieve good mixing and provide acceptable comfort levels. Recommendations are given on the operating conditions to guarantee occupant comfort.

Ridouane, E. H.

2011-09-01T23:59:59.000Z

464

up to air  

NLE Websites -- All DOE Office Websites (Extended Search)

to room temperature, Turn blower heaters off Open and lock the breaker to the heat system Close GN2 purge valve Diconnect and plug GN2...

465

VELOCITY MEASUREMENTS FOR A SOLAR ACTIVE REGION FAN LOOP FROM HINODE/EIS OBSERVATIONS  

Science Conference Proceedings (OSTI)

The velocity pattern of a fan loop structure within a solar active region over the temperature range 0.15-1.5 MK is derived using data from the EUV Imaging Spectrometer (EIS) on board the Hinode satellite. The loop is aligned toward the observer's line of sight and shows downflows (redshifts) of around 15 km s{sup -1} up to a temperature of 0.8 MK, but for temperatures of 1.0 MK and above the measured velocity shifts are consistent with no net flow. This velocity result applies over a projected spatial distance of 9 Mm and demonstrates that the cooler, redshifted plasma is physically disconnected from the hotter, stationary plasma. A scenario in which the fan loops consist of at least two groups of 'strands'-one cooler and downflowing, the other hotter and stationary-is suggested. The cooler strands may represent a later evolutionary stage of the hotter strands. A density diagnostic of Mg VII was used to show that the electron density at around 0.8 MK falls from 3.2 Multiplication-Sign 10{sup 9} cm{sup -3} at the loop base, to 5.0 Multiplication-Sign 10{sup 8} cm{sup -3} at a projected height of 15 Mm. A filling factor of 0.2 is found at temperatures close to the formation temperature of Mg VII (0.8 MK), confirming that the cooler, downflowing plasma occupies only a fraction of the apparent loop volume. The fan loop is rooted within a so-called outflow region that displays low intensity and blueshifts of up to 25 km s{sup -1} in Fe XII {lambda}195.12 (formed at 1.5 MK), in contrast to the loop's redshifts of 15 km s{sup -1} at 0.8 MK. A new technique for obtaining an absolute wavelength calibration for the EIS instrument is presented and an instrumental effect, possibly related to a distorted point-spread function, that affects velocity measurements is identified.

Young, P. R. [College of Science, George Mason University, 4400 University Drive, Fairfax, VA 22030 (United States); O'Dwyer, B.; Mason, H. E. [Department of Applied Mathematics and Theoretical Physics, University of Cambridge, Wilberforce Road, Cambridge, CB3 0WA (United Kingdom)

2012-01-01T23:59:59.000Z

466

A high-resolution 2-DH numerical scheme for process-based modeling of 3-D turbidite fan stratigraphy  

Science Conference Proceedings (OSTI)

A generic three-dimensional process-based model is presented, aimed at simulation of the construction of turbidite fan stratigraphy by low-density turbidity current events. It combines theoretical formulations on density flow and sediment transport of ... Keywords: MacCormack scheme, Operator splitting, Shock-capturing technique, Stratigraphic modeling, Turbidite reservoirs, Turbidity currents

Remco M. Groenenberg; Kees Sloff; Gert Jan Weltje

2009-08-01T23:59:59.000Z

467

Study of the Effects of Ambient Conditions Upon the Performance of Fan Powered, Infrared Natural Gas Burners  

SciTech Connect

The objective of this investigation was to characterize the operation of a fan-powered, infrared burner (IR burner) at various gas compositions and ambient conditions, develop numerical model to simulate the burner performances, and provide design guidelines for appliances containing PIR burners for satisfactory performance.

Clark Atlanta University

2002-12-02T23:59:59.000Z

468

Towards a syntactic signature for domain models: proposed descriptive metrics for visualizing the entity fan-out frequency distribution  

Science Conference Proceedings (OSTI)

The main objective of this paper is to find a minimal set of measures that allow the immediate, intuitive characterisation and visualization of the syntactic structure of models covering a particular application domain. The measures are validated ... Keywords: case measures, enterprise models, entity fan-out distribution, metrics, model analysis, model complexity, modelling

Jean-Paul van Belle

2002-09-01T23:59:59.000Z

469

Simulation of a mannequin's thermal plume in a small room  

Science Conference Proceedings (OSTI)

Simulation results are presented for the buoyancy-driven flow in a small room containing a seated mannequin that is maintained at a constant temperature. The study was motivated, in part, by a published experimental study of the thermal plume around ... Keywords: Heated mannequin, Lattice Boltzmann method, Particle trajectories, Small room, Thermal plume

Xinli Jia; John B. Mclaughlin; Jos Derksen; Goodarz Ahmadi

2013-01-01T23:59:59.000Z

470

Physical Education Building Building Room Material Amount Percentage Priority Action  

E-Print Network (OSTI)

Physical Education Building Building Room Material Amount Percentage Priority Action Phys Ed Level Mechanical Insulation 250 LF 70.00 P6 Manage Phys Ed Level 1 East PE1H2 Pipe Fitting Mud 6 each 85.00 P5 #12;Building Room Material Amount Percentage Priority Action Phys Ed Level 2 West PE200 Pipe Fitting

Seldin, Jonathan P.

471

Service Building 4 Building Room Material Amount Percentage Priority Action  

E-Print Network (OSTI)

Service Building 4 Building Room Material Amount Percentage Priority Action Service Building 4 S160 65 sqft 15.00 P5 Manage S1J74 Friday, February 18, 2011 Page 1 of 2 #12;Building Room Material Amount Manage Mechanical Insulation 100 LF 55.00 P5 Manage Service Buliding 4 S16H6A Gypsum Wallboard Joint

Seldin, Jonathan P.

472

Laboratory evaluation of fan/filter units' aerodynamic and energy performance  

SciTech Connect

The paper discusses the benefits of having a consistent testing method to characterize aerodynamic and energy performance of FFUs. It presents evaluation methods of laboratory-measured performance of ten relatively new, 1220 mm x 610 mm (or 4 ft x 2 ft) fan-filter units (FFUs), and includes results of a set of relevant metrics such as energy performance indices (EPI) based upon the sample FFUs tested. This paper concludes that there are variations in FFUs' performance, and that using a consistent testing and evaluation method can generate compatible and comparable FFU performance information. The paper also suggests that benefits and opportunities exist for our method of testing FFU energy performance to be integrated in future recommended practices.

Xu, Tengfang; Jeng, Ming-Shan

2004-07-27T23:59:59.000Z

473

Sand-rich submarine fans, Mio-Pliocene of Santa Monica Basin, offshore California: Untapped exploration targets  

Science Conference Proceedings (OSTI)

Santa Monica Basin lies directly west of Los Angeles Basin, one of the world's most prolific oil provinces. Published literature suggests that Santa Monica Basin was starved of coarse clastics during the late Miocene through Pliocene. However, seismic sequence stratigraphy indicates that deposition of sand-rich fans alternated with mixed-load systems throughout the Delmontian and Repettian stages. Seismic sequences and facies are calibrated to seismic and well data from Beta Oil Field, in San Pedro Basin to the south. Eustasy evidently played a dominant role in controlling sedimentation. Variations in tan lithology, thickness, and basinward extent correspond to worldwide changes in sea level. Regional erosion surfaces apparently signify drops in sea level. Overlying thick seismic packages display hummocky to chaotic seismic facies separated by high- to low-amplitude continuous reflections. These configurations are interpreted as inner- to mid-fan channels separated by overbank deposits in sand-rich lowstand fans. High-amplitude basinwide reflections bound the tops of the sand-rich intervals, and likely represent condensed sections formed during sea-level rises. Thin seismic intervals above the condensed sections display downlap, and are interpreted as interbedded sandstones and shales of prograding highstand fans. Sediment input to Santa Monica Basin, based on seismic-facies and isochron patterns, was predominantly from the (present-day) north, with subordinate input from the east. High-amplitude eustatic variations dominated deposition and sequence development even in this tectonically active basin Previously unidentified sand-rich fans are present, and have not been drilled.

May, J.A.; McMillen, K.J.

1996-01-01T23:59:59.000Z

474

Anaheim Public Utilities - Residential Home Efficiency Rebate Program |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Home Efficiency Rebate Residential Home Efficiency Rebate Program Anaheim Public Utilities - Residential Home Efficiency Rebate Program < Back Eligibility Low-Income Residential Multi-Family Residential Residential Savings Category Heating & Cooling Cooling Commercial Heating & Cooling Appliances & Electronics Home Weatherization Commercial Weatherization Sealing Your Home Ventilation Manufacturing Commercial Lighting Lighting Windows, Doors, & Skylights Maximum Rebate Air Duct Repair: $300 Ceiling Fan: 3 fans Program Info State California Program Type Utility Rebate Program Rebate Amount Refrigerator: $50 Refrigerator Recycling: $50 Dishwasher: $50 Room A/C: $50 Central A/C: $100/ton High Performance windows: $1/sq ft Air Duct Repair: 50% of repair cost Ceiling Fan: $20 Whole House Fan: $100

475

Review articles Outbreaks associated to large open air festivals,  

E-Print Network (OSTI)

In the minds of many, large scale open air festivals have become associated with spring and summer, attracting many people, and in the case of music festivals, thousands of music fans. These festivals share the usual health risks associated with large mass gatherings, including transmission of communicable diseases and risk of outbreaks. Large scale open air festivals have however specific characteristics, including outdoor settings, on-site housing and food supply and the generally young age of the participants. Outbreaks at large scale open air festivals have been caused by Cryptosporium parvum, Campylobacter spp., Escherichia coli, Salmonella enterica, Shigella sonnei, Staphylococcus aureus, hepatitis A virus, influenza virus, measles virus, mumps virus and norovirus. Faecal-oral and respiratory transmissions of pathogens result from non-compliance with hygiene rules, inadequate sanitation and insufficient vaccination coverage. Sexual transmission of infectious diseases may also occur and is likely to be underestimated and underreported. Enhanced surveillance during and after festivals is essential. Preventive measures such as immunisations of participants and advice on-site and via social networks should be considered to reduce outbreaks at these large scale open air festivals.

unknown authors

2012-01-01T23:59:59.000Z

476

Air-Source Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

the wall of a house. Inside the house the refrigerant winds through indoor coils, with a fan blowing across them, and outside the house is another fan and another set of coils, the...

477

Brig. Gen. Dawkins honored at Air Force promotion ceremony | National  

NLE Websites -- All DOE Office Websites (Extended Search)

Dawkins honored at Air Force promotion ceremony | National Dawkins honored at Air Force promotion ceremony | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Brig. Gen. Dawkins honored at Air Force ... Brig. Gen. Dawkins honored at Air Force promotion ceremony Posted By Office of Public Affairs Brig. Gen. Dawkins honored at Air Force promotion ceremony

478

Energy Basics: Solar Air Heating  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

EERE: Energy Basics Solar Air Heating Solar air heating systems use air as the working fluid for absorbing and transferring solar energy. Solar air collectors (devices to heat air...

479

Quantitative room-temperature mineralization of airborne formaldehyde using  

NLE Websites -- All DOE Office Websites (Extended Search)

Quantitative room-temperature mineralization of airborne formaldehyde using Quantitative room-temperature mineralization of airborne formaldehyde using manganese oxide catalysts Title Quantitative room-temperature mineralization of airborne formaldehyde using manganese oxide catalysts Publication Type Journal Article Year of Publication 2011 Authors Sidheswaran, Meera A., Hugo Destaillats, Douglas P. Sullivan, Joern Larsen, and William J. Fisk Journal Applied Catalysis B - Environmental Issue 107 Pagination 34-41 Date Published 2011 Keywords commercial building ventilation & indoor environmental quality group, commercial building ventilation and indoor environmental quality group, energy analysis and environmental impacts department, indoor environment department, indoor environment group DOI 10.1016/j.apcatb.2011.06.032 Attachment Size

480

How much sense do room occupancy sensor controls make  

SciTech Connect

Hotel operators are faced with a confusing array of both remote and local guest room energy control devices. A wide variety of decentralized electronic room controllers, each with its own control logic and vendor claims are in competition with remote front desk microprocessor controls which are essentially ''blind'' to actual occupancy. This paper is a review of the characteristics of various controllers, their behaviour with different in-room environmental equipment, and guest reactions to the potpourri of available devices.

Becker, H.P.

1986-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "fans room air" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Use of seawater for air conditioning at Waikiki Convention Center. Master's thesis  

SciTech Connect

A large part of operating costs of a hotel in Hawaii is the cost of energy for air conditioning. Buildings can be constructed to use energy more efficiently by using many methods, however, some of these methods conflict with other concerns, aesthetics for example. Thus the process of designing and building an energy efficient hotel often involves trade-offs between energy efficiency and other objectives. The method proposed herein to reduce energy costs is to introduce seawater, pumped from the deep ocean at a temperature of approximately six degrees celsius, directly to heat exchangers which cool the chilled water circulating in the building air conditioning system. The energy required to run the system would be reduced to only the cost of the seawater pumps, the fans and controls. The savings would be in the operating costs of the seawater pumps versus the cost to the compressors of a conventional air conditioning system.

Williams, M.

1994-01-01T23:59:59.000Z

482

DOE-HDBK-1169-2003; DOE Handbook Nuclear Air Cleaning Handbook  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5-1 5-1 CHAPTER 5 EXTERNAL COMPONENTS 5.1 Introduction External components of an air cleaning system include fans, ductwork, dampers, louvers, stacks, instruments, and other miscellaneous accessories that are associated with the movement, control, conveying, and monitoring of the air or gas flow. This chapter contains information on the design, fabrication, materials, and codes and standards requirements/considerations for air cleaning system external components for nuclear facilities. Additional information can be found in Chapters 2 and 4, as well as ASME Code AG-1. 1 Use of AG-1 requirements is mandatory for Safety Class and Safety Significant Systems and can be used as guidance for lower systems. 5.2 Ductwork This section will address the functional design, mechanical design, materials, coatings, supports, acoustic

483

Isokinetic air sampler  

DOE Patents (OSTI)

An isokinetic air sampler includes a filter, a holder for the filter, an air pump for drawing air through the filter at a fixed, predetermined rate, an inlet assembly for the sampler having an inlet opening therein of a size such that isokinetic air sampling is obtained at a particular wind speed, a closure for the inlet opening and means for simultaneously opening the closure and turning on the air pump when the wind speed is such that isokinetic air sampling is obtained. A system incorporating a plurality of such samplers provided with air pumps set to draw air through the filter at the same fixed, predetermined rate and having different inlet opening sizes for use at different wind speeds is included within the ambit of the present invention as is a method of sampling air to measure airborne concentrations of particulate pollutants as a function of wind speed.

Sehmel, George A. (Richland, WA)

1979-01-01T23:59:59.000Z

484

Assessment of Indoor Air Quality Benefits and Energy Costs of Mechanical Ventilation  

Science Conference Proceedings (OSTI)

Intake of chemical air pollutants in residences represents an important and substantial health hazard. Sealing homes to reduce air infiltration can save space conditioning energy, but can also increase indoor pollutant concentrations. Mechanical ventilation ensures a minimum amount of outdoor airflow that helps reduce concentrations of indoor emitted pollutants while requiring some energy for fan(s) and thermal conditioning of the added airflow. This work demonstrates a physics based, data driven modeling framework for comparing the costs and benefits of whole-house mechanical ventilation and applied the framework to new California homes. The results indicate that, on a population basis, the health benefits from reduced exposure to indoor pollutants in New California homes are worth the energy costs of adding mechanical ventilation as specified by ASHRAE Standard 62.2.This study determines the health burden for a subset of pollutants in indoor air and the costs and benefits of ASHRAE's mechanical ventilation standard (62.2) for new California homes. Results indicate that, on a population basis, the health benefits of new home mechanical ventilation justify the energy costs.

Logue, J.M.; Price, P.N.; Sherman, M.H.; Singer, B.C.

2011-07-01T23:59:59.000Z

485

WIPP Reaches Milestone „ First Disposal Room Filled  

NLE Websites -- All DOE Office Websites (Extended Search)

WIPP Reaches Milestone - First Disposal Room Filled CARLSBAD, N.M., September 4, 2001 - The U.S. Department of Energy's (DOE) Carlsbad Field Office today announced that Room 7 of Panel 1 at the Waste Isolation Pilot Plant (WIPP), the first underground room used for disposal operations, has been filled to capacity with transuranic waste. The milestone was reached at about 3:30 p.m. on August 24, as Waste Handling personnel emplaced a shipment of waste from the Idaho National Engineering and Environmental Laboratory. On August 25, Underground Operations personnel completed installation of a chain link mesh barrier and cloth drape across the entrance to the room to officially declare the area "closed." The first shipment of waste, which came

486

Dorm Room Idea Now Revolutionizing Energy | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Dorm Room Idea Now Revolutionizing Energy Dorm Room Idea Now Revolutionizing Energy Dorm Room Idea Now Revolutionizing Energy April 16, 2010 - 11:07am Addthis Joshua DeLung What does this project do? Princeton Power Systems is currently installing a 200-kW solar array and advanced battery system on company grounds to provide clean power to its building and to showcase advancements in renewable energy technology to businesses, municipalities and utilities that may be curious about renewable energy projects. While many college students might spend their time playing Ultimate Frisbee or enjoying the nightlife, Darren Hammell and several other Princeton University classmates transformed an idea fostered in a dorm room into one of the fastest-growing businesses in the energy industry, creating jobs and

487

Virtual Reading Room prior to 2000 | National Nuclear Security  

National Nuclear Security Administration (NNSA)

prior to 2000 | National Nuclear Security prior to 2000 | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Virtual Reading Room prior to 2000 Home > About Us > Our Operations > NNSA Office of General Counsel > Freedom of Information Act (FOIA) > Virtual Reading Room prior to 2000 Virtual Reading Room prior to 2000 Printer-friendly version Printer-friendly version