Powered by Deep Web Technologies
Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Steam atmosphere drying exhaust steam recompression system  

DOE Patents [OSTI]

This invention relates to a heated steam atmosphere drying system comprising dryer in combination with an exhaust recompression system which is extremely energy efficient and eliminates dangers known to air dryers. The system uses superheated steam as the drying medium, which recirculates through the system where its heat of evaporation and heat of compression is recovered, thereby providing a constant source of heat to the drying chamber. The dryer has inlets whereby feedstock and superheated steam are fed therein. High heat transfer and drying rates are achieved by intimate contact of the superheated steam with the particles being dried. The dryer comprises a vessel which enables the feedstock and steam to enter and recirculate together. When the feedstock becomes dry it will exit the dryer with the steam and become separated from the steam through the use of a curvilinear louver separator (CLS). The CLS enables removal of fine and ultrafine particles from the dryer. Water vapor separated from the particles in the CLS as superheated steam, may then be recovered and recirculated as steam through the use of a compressor to either directly or indirectly heat the dryer, and a heat exchanger or a heater to directly provide heat to the dryer. This system not only provides a very efficient heat transfer system but results in a minimum carry-over of ultrafine particles thereby eliminating any explosive hazard. 17 figures.

Becker, F.E.; Smolensky, L.A.; Doyle, E.F.; DiBella, F.A.

1994-03-08T23:59:59.000Z

2

Steam atmosphere drying exhaust steam recompression system  

DOE Patents [OSTI]

This invention relates to a heated steam atmosphere drying system comprising dryer in combination with an exhaust recompression system which is extremely energy efficient and eliminates dangers known to air dryers. The system uses superheated steam as the drying medium, which recirculated through the system where its heat of evaporation and heat of compression is recovered, thereby providing a constant source of heat to the drying chamber. The dryer has inlets whereby feedstock and superheated steam are fed therein. High heat transfer and drying rates are achieved by intimate contact of the superheated steam with the particles being dried The dryer comprises a vessel which enables the feedstock and steam to enter recirculate together. When the feedstock becomes dry it will exit the dryer with the steam and become separated from the steam through the use of a curvilinear louver separator (CLS). The CLS enables removal of fine and ultrafine particles from the dryer. Water vapor separated from the particles in the CLS as superheated steam, may then be recovered and recirculated as steam through the use of a compressor to either directly or indirectly heat the dryer, and a heat exchanger or a heater to directly provide heat to the dryer. This system not only provides a very efficient heat transfer system but results in a minimum carry-over of ultrafine particles thereby eliminating any explosive hazard.

Becker, Frederick E. (Reading, MA); Smolensky, Leo A. (Concord, MA); Doyle, Edward F. (Dedham, MA); DiBella, Francis A. (Roslindale, MA)

1994-01-01T23:59:59.000Z

3

Drum drying of black liquor using superheated steam impinging jets  

SciTech Connect (OSTI)

A novel drum dryer for black liquor utilizing multiple impinging jets of superheated steam was designed and built to evaluate the performance characteristics and effects of various operating parameters thereon. Appropriate ranges of parameters such as steam jet temperature and velocity were examined experimentally to quantify the optimal operating conditions for the formation of black liquor film on the drum surface as well as the drying kinetics.

Shiravi, A.H.; Mujumdar, A.S.; Kubes, G.J. [McGill Univ., Montreal, Quebec (Canada)

1997-05-01T23:59:59.000Z

4

Experimental and analytical studies of hydrocarbon yields under dry-, steam-, and steam-with-propane distillation  

E-Print Network [OSTI]

EXPERIMENTAL AND ANALYTICAL STUDIES OF HYDROCARBON YIELDS UNDER DRY-, STEAM-, AND STEAM-WITH- PROPANE DISTILLATION A Dissertation by NAMIT JAISWAL Submitted to the Office of Graduate Studies of Texas A&M University...-WITH- PROPANE-DISTILLATION A Dissertation by NAMIT JAISWAL Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY Approved...

Jaiswal, Namit

2007-09-17T23:59:59.000Z

5

Mathematical model of steam drying of wood chips and other hygroscopic porous media  

SciTech Connect (OSTI)

A model is presented that is focused on the drying kinetics of single wood chips as a function of time and external conditions, such as temperature, pressure and velocity of the superheated steam. A multiphase and 2-D approach was used to model the coupled transport of water, vapor, air and heat in anisotropic hygroscopic porous media. The model was verified by drying experiments where measurements of the average moisture content, center temperature and pressure in a single wood chip could be performed simultaneously. A comparison between the calculations and the measurements showed that the drying behavior was well predicted. The drying can be divided into three stages: a heat-up period when condensation on the surface initially increases the moisture content; a period of constant drying rate when the external heat transfer controls the drying rate; and a period of decreasing drying rate when the drying is controlled by internal mass transfer. Many interesting features of the drying could be assigned to the strong anisotropicity of wood, which makes a 2-D model necessary.

Fyhr, C.; Rasmuson, A. [Chalmers Univ. of Technology, Gothenburg (Sweden). Dept. of Chemical Engineering Design] [Chalmers Univ. of Technology, Gothenburg (Sweden). Dept. of Chemical Engineering Design

1996-09-01T23:59:59.000Z

6

Steam in Distribution and Use: Steam Quality Redefined  

E-Print Network [OSTI]

"Steam quality is an important measurement in steam generation. It's a measurement of steam to moisture ratio. In use, steam quality takes on a different meaning - steam which maximizes energy transfer. To do this, the steam must be clean, dry...

Deacon, W.

7

Steam in Distribution and Use: Steam Quality Redefined  

E-Print Network [OSTI]

Steam quality is an important measurement in steam generation. It's a measurement of steam to moisture ratio. In use, steam quality takes on a different meaning- steam which maximizes energy transfer. To do this, the steam must be clean, dry...

Deacon, W. T.

8

Steam Quality  

E-Print Network [OSTI]

"STEAM QUALITY has been generally defined as the amount of moisture/vapor (or lack thereof) contained within steam produced from some form of boiler. It has long been used as the standard term for the measurement of ""wet or dry"" steam and as a...

Johnston, W.

9

Steam Power Partnership: Improving Steam System Efficiency Through Marketplace Partnerships  

E-Print Network [OSTI]

to support the steam efficiency program. Today, the Steam Team includes, the North American Insulation Manufacturers Association (NAIMA), the American Gas Association (AGA), the Council of Industrial Boiler Owners (ClBO), Armstrong International... pinch technology, and high performance steam. ? Armstrong International - Three worldwide factory seminar facilities, 13 North American sales representative facilities, 4 international sales representative facilities, 8 co-sponsored facilities, 2...

Jones, T.

10

CIBO's Energy Efficiency Handbook for Steam Power Systems  

E-Print Network [OSTI]

The Council of Industrial Boiler Owners (CIBO) has developed a handbook to help boiler operators get the best performance from their industrial steam systems. This energy efficiency handbook takes a comprehensive look at the boiler and steam system...

Bessette, R. D.

11

Reduce Steam Trap Failures at Chambers Works  

E-Print Network [OSTI]

Ultrasonic Inspection At least 2 times per year Steam Trap Surveyor Submit reports to area management, energy team, and reliability engineers for each area every month Steam Trap Team Leader Control Plan ? Process Owner agrees...Reduce Steam Trap Failures at Chambers Works GB/BB Name: Cyndi Kouba Mentor/MBB: Andrew Degraff Team Members Michael Crowley(Site Energy Lead), (Charlie) Flanigan (Aramids-maintenance), Ben Snyder (Aramids-ATO), Michael Scruggs (Central...

Kouba, C.

12

Superheated steam power plant with steam to steam reheater. [LMFBR  

SciTech Connect (OSTI)

A desuperheater is disposed in a steam supply line supplying superheated steam to a shell and tube reheater.

Silvestri, G.J.

1981-06-23T23:59:59.000Z

13

Business Owners: Prepare for Utility Disruptions | Department...  

Broader source: Energy.gov (indexed) [DOE]

Utility Disruptions Business Owners: Prepare for Utility Disruptions Business Owners: Prepare for Utility Disruptions Have a plan in place in case a natural disaster or other...

14

Thomas Reddinger Director, Steam  

E-Print Network [OSTI]

Thomas Reddinger Director, Steam Operations Steven Richards Assistant Manager of Maintenance (Distribution) Deborah Moorhead Office Coordinator III Martin Bower Steam Plant Operator Richard Redfield Steam Plant Operator Bohdan Sawa Steam Plant Operator Robert Tedesco Steam Plant Operator James Bradley

Raina, Ramesh

15

Thomas Reddinger Director, Steam  

E-Print Network [OSTI]

Thomas Reddinger Director, Steam Operations Steven Richards Assistant Manager of Maintenance Bourdon Steam Plant Operator Vincent Massara Steam Plant Operator Cliff Lescenski Steam Plant Operator Robert Tedesco Steam Plant Operator James Bradley Equipment Maintenance Robert Earle Equipment

Mather, Patrick T.

16

Steam Pricing  

E-Print Network [OSTI]

as useable horsepower for pumps, compressors, etc. The turbines can be topping turbines which admit steam at a high pressure and exhaust it at a lower pressure, but a pressure which is still high enough to be used as a source of heat. Or, the turbines... can be condensing turbines which exhaust the steam at a pressure too low for the remaining heat to be useable. In this case the exhaust steam is normally condensed using cooling water, and the condensate is returned to the boiler house. Our plant...

Jones, K. C.

17

Owners of nuclear power plants  

SciTech Connect (OSTI)

Commercial nuclear power plants in this country can be owned by a number of separate entities, each with varying ownership proportions. Each of these owners may, in turn, have a parent/subsidiary relationship to other companies. In addition, the operator of the plant may be a different entity as well. This report provides a compilation on the owners/operators for all commercial power reactors in the United States. While the utility industry is currently experiencing changes in organizational structure which may affect nuclear plant ownership, the data in this report is current as of July 1996. The report is divided into sections representing different aspects of nuclear plant ownership.

Hudson, C.R.; White, V.S.

1996-11-01T23:59:59.000Z

18

Steam Turbine Cogeneration  

E-Print Network [OSTI]

Steam turbines are widely used in most industrial facilities because steam is readily available and steam turbine is easy to operate and maintain. If designed properly, a steam turbine co-generation (producing heat and power simultaneously) system...

Quach, K.; Robb, A. G.

2008-01-01T23:59:59.000Z

19

OWNER'S MANUAL IPS LED MONITOR  

E-Print Network [OSTI]

www.lg.com OWNER'S MANUAL IPS LED MONITOR (LED LCD MONITOR) 27EA83 27EA83R Please read the safety different licenses. Visit www.lg.com for more information on the license. VESA, VESA logo, Display Port of the Video Electronics Standards Association. The terms HDMI and HDMI High-Definition Multimedia Interface

Ott, Albrecht

20

Steam Path Audits on Industrial Steam Turbines  

E-Print Network [OSTI]

steam Path Audits on Industrial steam Turbines DOUGLAS R. MITCHELL. ENGINEER. ENCOTECH, INC., SCHENECTADY, NEW YORK ABSTRACT The electric utility industry has benefitted from steam path audits on steam turbines for several years. Benefits... not extend the turbine outage. To assure that all of the turbine audit data are available, the audit engineer must be at the turbine site the day the steam path is first exposed. A report of the opening audit findings is generated to describe the as...

Mitchell, D. R.

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Thomas Reddinger Director, Steam  

E-Print Network [OSTI]

Thomas Reddinger Director, Steam Operations Steven Richards Assistant Manager of Maintenance Supervisor (Distribution) Deborah Moorhead Office Coordinator III Martin Bower Steam Plant Operator Richard Redfield Steam Plant Operator SU Steam Station/Chilled Water Plant Bohdan Sawa Steam Plant Operator Robert

McConnell, Terry

22

Experience in the repair of steam generator auxiliary feedwater nozzle  

SciTech Connect (OSTI)

The auxiliary feedwater nozzle is quite often subjected to more thermal stress cycles and other loading mechanisms during their service life than the material was designed and fabricated for at the nozzle of the earlier steam generators in many nuclear plants. During plant operation, the auxiliary feedwater nozzle outlet is exposed to the hot steam from the generator side, while the auxiliary feedwater piping which contains subcooled water from the inlet often induces water hammer as a result of the steam-water mixing phenomena. The thermal cycles and the steam bubble collapse at the nozzle may cause cracking in the nozzle liner and interior surface of the nozzle, and subsequently results in structural damage to the steam generator. This presentation is intended to share the lessons learned from the evaluation of the nozzle condition and the subsequent modification and repair made to the auxiliary feedwater nozzle at the Palisades Nuclear Plant. Other nuclear plant owners may benefit from this experience.

Chao, K.K.N. [Consumers Power Co., Jackson, MI (United States)

1996-12-01T23:59:59.000Z

23

Steam System Optimization  

E-Print Network [OSTI]

flanges, control valves, steam turbines, manways, sections of piping, heads on vessels, etc. are uninsulated. If steam is in demand at the steam pressure level of the uninsulated piping and equipment, then the piping and equipment should be insulated... been developed, it is an excellent tool to identify the steam sources. Areas to first look for possible waste are steam turbines and steam let down stations. 161 ESL-IE-98-04-26 Proceedings from the Twentieth National Industrial Energy Technology...

Aegerter, R. A.

24

Steam and Condensate Systems  

E-Print Network [OSTI]

efficiency and profit. Some important factors to consider in steam and condensate systems are: 1) Proper steam pressure 2) Adequate sized steam lines 3) Adequate sized condensate return lines 4) Utilization of flash steam 5) Properly sized... ! can cause system inefficiency. i Adequate sized steam lines assure the process will be furnished with sufficiertt i quantities of steam at the proper pressure. Adequate sized condensate return lines are essential to overall efficiency. lhese...

Yates, W.

1979-01-01T23:59:59.000Z

25

SteamMaster: Steam System Analysis Software  

E-Print Network [OSTI]

STEAMMASTER: STEAM SYSTEM ANALYSIS SOFTW ARE Greg Wheeler Associate Professor Oregon State University Corvallis, OR 9733 I ABSTRACT As director of Oregon's ]ndustrial Assessment Center, [ have encountered many industrial steam systems during... plant visits. We analyze steam systems and make recommendations to improve system efficiency. [n nearly 400 industrial assessments, we have recommended 210 steam system improvements, excluding heat recovery, that would save $1.5 million/year with a...

Wheeler, G.

26

Corporate Law's Current-Owner Bias  

E-Print Network [OSTI]

Owner Bias in Corporate Governance Jesse Fried * Boalt Hallmy conclusion that corporate governance arrangements choseninterventions in corporate governance through the securities

Fried, Jesse M.

2005-01-01T23:59:59.000Z

27

Corporate Law's Current-Owner Bias  

E-Print Network [OSTI]

Owner Bias in Corporate Governance Jesse Fried * Boalt Hallmy conclusion that corporate governance arrangements choseninterventions in corporate governance through the securities

Fried, Jesse M.

2006-01-01T23:59:59.000Z

28

Drying of fiber webs  

DOE Patents [OSTI]

A process and an apparatus for high-intensity drying of fiber webs or sheets, such as newsprint, printing and writing papers, packaging paper, and paperboard or linerboard, as they are formed on a paper machine. The invention uses direct contact between the wet fiber web or sheet and various molten heat transfer fluids, such as liquified eutectic metal alloys, to impart heat at high rates over prolonged durations, in order to achieve ambient boiling of moisture contained within the web. The molten fluid contact process causes steam vapor to emanate from the web surface, without dilution by ambient air; and it is differentiated from the evaporative drying techniques of the prior industrial art, which depend on the uses of steam-heated cylinders to supply heat to the paper web surface, and ambient air to carry away moisture, which is evaporated from the web surface. Contact between the wet fiber web and the molten fluid can be accomplished either by submersing the web within a molten bath or by coating the surface of the web with the molten media. Because of the high interfacial surface tension between the molten media and the cellulose fiber comprising the paper web, the molten media does not appreciately stick to the paper after it is dried. Steam generated from the paper web is collected and condensed without dilution by ambient air to allow heat recovery at significantly higher temperature levels than attainable in evaporative dryers.

Warren, David W. (9253 Glenoaks Blvd., Sun Valley, CA 91352)

1997-01-01T23:59:59.000Z

29

Drying of fiber webs  

DOE Patents [OSTI]

A process and an apparatus are disclosed for high-intensity drying of fiber webs or sheets, such as newsprint, printing and writing papers, packaging paper, and paperboard or linerboard, as they are formed on a paper machine. The invention uses direct contact between the wet fiber web or sheet and various molten heat transfer fluids, such as liquefied eutectic metal alloys, to impart heat at high rates over prolonged durations, in order to achieve ambient boiling of moisture contained within the web. The molten fluid contact process causes steam vapor to emanate from the web surface, without dilution by ambient air; and it is differentiated from the evaporative drying techniques of the prior industrial art, which depend on the uses of steam-heated cylinders to supply heat to the paper web surface, and ambient air to carry away moisture, which is evaporated from the web surface. Contact between the wet fiber web and the molten fluid can be accomplished either by submersing the web within a molten bath or by coating the surface of the web with the molten media. Because of the high interfacial surface tension between the molten media and the cellulose fiber comprising the paper web, the molten media does not appreciatively stick to the paper after it is dried. Steam generated from the paper web is collected and condensed without dilution by ambient air to allow heat recovery at significantly higher temperature levels than attainable in evaporative dryers. 6 figs.

Warren, D.W.

1997-04-15T23:59:59.000Z

30

SAFETY MANUAL Fishermen, Captains, and Owners  

E-Print Network [OSTI]

I~o SAFETY MANUAL for Fishermen, Captains, and Owners of New England Fishing Vessels #12;UNITED--now and in the future. #12;SAFETY MANUAL for Fishermen, Captains, and Owners of New England Fishing Vessels Adapted for the fishing industry by John J. Murray Regional Safety Officer Bureau of Commercial Fisheries U.S. Fish

31

The B & W Owners` Group Generic License Renewal Program  

SciTech Connect (OSTI)

Since the late 1970s, the Babcock & Wilcox (B & W) Owners Group (BWOG) has sponsored significant activities that address technical, economic, and licensing issues to ensure that the B & W nuclear steam supply system (NSSS) power plants operate until the end of their current plant licensed life and to preserve the license renewal option. It should be no surprise that the BWOG decided in late 1992 to aggressively pursue a license renewal effort. This effort, the Generic License Renewal Program (GLRP), has over the past 18 months contributed significantly to the industry`s license renewal initiative. The GLRP was established as a project with a full-time management organization within the BWOG structure. Its primary objective was the development and demonstration of an integrated plant assessment (IPA) process that would meet the requirements of the License Renewal Rule, published by the US Nuclear Regulatory Commission (NRC) in December 1991. The BWOG consists of five utilities with plants of very similar design, operation, and age. The owners, along with technical support from B & W Nuclear Technologies, created a highly capable and effective team to address the elements of the license renewal rule. This paper presents the BWOG strategy from the beginning of the program, the accomplishments to date, and the current role of the BWOG GLRP.

Gill, R.L. Jr.

1994-12-31T23:59:59.000Z

32

Steam Oxidation of Advanced Steam Turbine Alloys  

SciTech Connect (OSTI)

Power generation from coal using ultra supercritical steam results in improved fuel efficiency and decreased greenhouse gas emissions. Results of ongoing research into the oxidation of candidate nickel-base alloys for ultra supercritical steam turbines are presented. Exposure conditions range from moist air at atmospheric pressure (650癈 to 800癈) to steam at 34.5 MPa (650癈 to 760癈). Parabolic scale growth coupled with internal oxidation and reactive evaporation of chromia are the primary corrosion mechanisms.

Holcomb, Gordon R.

2008-01-01T23:59:59.000Z

33

Business Owners: Respond to an Energy Emergency | Department...  

Broader source: Energy.gov (indexed) [DOE]

Respond to an Energy Emergency Business Owners: Respond to an Energy Emergency Business Owners: Respond to an Energy Emergency Ensure your building is safe to occupy-Initially...

34

Downhole steam quality measurement  

DOE Patents [OSTI]

The present invention relates to an empirical electrical method for remote sensing of steam quality utilizing flow-through grids which allow measurement of the electrical properties of a flowing two-phase mixture. The measurement of steam quality in the oil field is important to the efficient application of steam assisted recovery of oil. Because of the increased energy content in higher quality steam it is important to maintain the highest possible steam quality at the injection sandface. The effectiveness of a steaming operation without a measure of steam quality downhole close to the point of injection would be difficult to determine. Therefore, a need exists for the remote sensing of steam quality.

Lee, D.O.; Montoya, P.C.; Muir, J.F.; Wayland, J.R. Jr.

1985-06-19T23:59:59.000Z

35

Steam Digest 2001  

SciTech Connect (OSTI)

Steam Digest 2001 chronicles BestPractices Program's contributions to the industrial trade press for 2001, and presents articles that cover technical, financial and managerial aspects of steam optimization.

Not Available

2002-01-01T23:59:59.000Z

36

Steam and Condensate Systems  

E-Print Network [OSTI]

.00 or more. Many see costs of $6.00/$7.00 in the near future. These tremendous increases have caused steam systems, steam traps and condensate systems to become a major factor in overall plant efficiency and profit....

Yates, W.

1980-01-01T23:59:59.000Z

37

Waste Steam Recovery  

E-Print Network [OSTI]

applicable to other sources of steam. The interaction of the recovery system with the plant's steam/power system has been included. Typical operating economics have been prepared. It was found that the profitability of most recovery schemes is generally...

Kleinfeld, J. M.

1979-01-01T23:59:59.000Z

38

Flash Steam Recovery Project  

E-Print Network [OSTI]

organic compounds, was targeted for improvement. This unit uses a portion of the high-pressure steam available from the plant's cogeneration facility. Continuous expansions within the unit had exceeded the optimum design capacity of the unit's steam...

Bronhold, C. J.

39

Downhole steam quality measurement  

DOE Patents [OSTI]

An empirical method for the remote sensing of steam quality that can be easily adapted to downhole steam quality measurements by measuring the electrical properties of two-phase flow across electrode grids at low frequencies.

Lee, David O. (Albuquerque, NM); Montoya, Paul C. (Albuquerque, NM); Muir, James F. (Albuquerque, NM); Wayland, Jr., J. Robert (Albuquerque, NM)

1987-01-01T23:59:59.000Z

40

HP Steam Trap Monitoring  

E-Print Network [OSTI]

STEAM MONITORING HP Steam Trap Monitoring HP Steam Trap Monitoring ? 12-18 months payback! ? 3-5% permanent reduction in consumption ? LEED Pt.? Innovation in Operations EB O&M ? Saved clients over $1,000,000 Annual consumption... Steam Trap Monitoring ? Real-time monitoring for high-pressure critical traps (>15 PSIG) ? Average total system cost $25K - $50K ? Web-Based or Modbus/BMS Integration Basic Installation Wireless Signal Transmitter Receiver Repeater...

Pascone, S.

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Steam trap monitor  

DOE Patents [OSTI]

A steam trap monitor positioned downstream of a steam trap in a closed steam system includes a first sensor (a hot finger) for measuring the energy of condensate and a second sensor (a cold finger) for measuring the total energy of condensate and steam in the line. The hot finger includes one or more thermocouples for detecting condensate level and energy, while the cold finger contains a liquid with a lower boiling temperature than that of water. Vapor pressure from the liquid is used to do work such as displacing a piston or bellow in providing an indication of total energy (steam + condensate) of the system. Processing means coupled to and responsive to outputs from the hot and cold fingers subtracts the former from the latter to provide an indication of the presence of steam downstream from the trap indicating that the steam trap is malfunctioning. 2 figs.

Ryan, M.J.

1987-05-04T23:59:59.000Z

42

Geothermal steam quality testing  

SciTech Connect (OSTI)

Geothermal steam quality and purity have a significant effect on the operational efficiency and life of geothermal steam turbines and accessory equipment. Poor steam processing can result in scaled nozzles/blades, erosion, corrosion, reduced utilization efficiency, and early fatigue failures accelerated by stress corrosion cracking (SCC). Upsets formed by undetected slugs of liquid entering the turbine can cause catastrophic failure. The accurate monitoring and determination of geothermal steam quality/purity is intrinsically complex which often results in substantial errors. This paper will review steam quality and purity relationships, address some of the errors, complexities, calibration and focus on: thermodynamic techniques for evaluating and monitoring steam quality by use of the modified throttling calorimeters.

Jung, D.B. [Two-Phase Engineering & Research, Inc., Santa Rosa, CA (United States)

1995-12-31T23:59:59.000Z

43

Improving steam turbine efficiency  

SciTech Connect (OSTI)

This paper describes the condition of a significant number of fossil steam turbines operating in the United States and the maintenance practices used to improve their performance. Through the use of steam path audits conducted by the authors` company and by several utilities, a large data base of information on turbine heat rate, casing efficiency, and maintenance practices is available to help the power generation industry understand how different maintenance practices and steam path damage impact turbine performance. The data base reveals that turbine cycle heat rate is typically 5.23% poorer than design just prior to major outages. The degraded condition of steam turbines presents an opportunity for utilities to improve heat rate and reduce emissions without increasing fuel costs. The paper describes what losses typically contribute to the 5.23% heat rate degradation and how utilities can recover steam turbine performance through maintenance actions aimed at improving steam path efficiency.

Cioffi, D.H.; Mitchell, D.R.; Whitecar, S.C. [Encotech, Inc., Schenectady, NY (United States)

1995-06-01T23:59:59.000Z

44

Steam generator support system  

DOE Patents [OSTI]

A support system for connection to an outer surface of a J-shaped steam generator for use with a nuclear reactor or other liquid metal cooled power source is disclosed. The J-shaped steam generator is mounted with the bent portion at the bottom. An arrangement of elongated rod members provides both horizontal and vertical support for the steam generator. The rod members are interconnected to the steam generator assembly and a support structure in a manner which provides for thermal distortion of the steam generator without the transfer of bending moments to the support structure and in a like manner substantially minimizes forces being transferred between the support structure and the steam generator as a result of seismic disturbances. 4 figs.

Moldenhauer, J.E.

1987-08-25T23:59:59.000Z

45

Steam generator support system  

DOE Patents [OSTI]

A support system for connection to an outer surface of a J-shaped steam generator for use with a nuclear reactor or other liquid metal cooled power source. The J-shaped steam generator is mounted with the bent portion at the bottom. An arrangement of elongated rod members provides both horizontal and vertical support for the steam generator. The rod members are interconnected to the steam generator assembly and a support structure in a manner which provides for thermal distortion of the steam generator without the transfer of bending moments to the support structure and in a like manner substantially minimizes forces being transferred between the support structure and the steam generator as a result of seismic disturbances.

Moldenhauer, James E. (Simi Valley, CA)

1987-01-01T23:59:59.000Z

46

Predicting Steam Turbine Performance  

E-Print Network [OSTI]

," PREDICTING STEAM TURBINE PERFORMANCE James T. Harriz, EIT Waterland, Viar & Associates, Inc. Wilmington, Delaware ABSTRACT Tracking the performance of extraction, back pressure and condensing steam turbines is a crucial part... energy) and test data are presented. Techniques for deriving efficiency curves from each source are described. These techniques can be applied directly to any steam turbine reliability study effort. INTRODUCTION As the cost of energy resources...

Harriz, J. T.

47

Steam System Optimization  

E-Print Network [OSTI]

is being let down. Some projects are independent of the steam balance, such as eliminating high-pressure (HP) steam leaks, insulating HP steam piping, optimizing the boiler operation, and improving the performance of condensing turbines.... If dirty fuels are used, then soot blowing should be frequently performed and the economizers cleaned on a more frequent schedule. For sites with condensing turbines, the turbine blades and the surface condensers must remain clean to maintain...

Aegerter, R.

2004-01-01T23:59:59.000Z

48

Steam System Data Management  

E-Print Network [OSTI]

Steam System Data Management What Does It Include Safety In Motion Wal?Tech?Valve,?Inc. 251?438?2203 The Real Genius Behind Technology Is People ESL-IE-13-05-35 Proceedings of the Thrity-Fifth Industrial Energy Technology Conference New... ? Fabrication Training (Six Year Training) ? Welding Certifications ?Retired From Chevron After 25 Years ? Established A Steam System Program ? Planner For Routine Maintenance Work ? Planner For Steam System Improvements ? Wal-Tech Valve, Inc. ? Purchased...

Roberts, D.

2013-01-01T23:59:59.000Z

49

Steam reforming analyzed  

SciTech Connect (OSTI)

This paper reports that maximum steam reformer operation without excessive coking reactions requires careful control of thermodynamic and kinetic conditions. Regardless of the syngas-based feedstock composition, carbon formation problems can be avoided while increasing reformer CO or H{sub 2} production. Steam reforming technology is best understood via: Primary steam reformer developments, Kinetics of methane steam reforming, Simulation of an industrial steam/CO{sub 2} reformer, Example conditions (steam/CO{sub 2} reforming), Thermodynamic approach (minimum to steam ratio). Hydrogen and carbon monoxide are two of the most important building blocks in the chemical industry. Hydrogen is mainly used in ammonia and methanol synthesis and petroleum refining. Carbon monoxide is used to produce pains, plastics, foams, pesticides and insecticides, to name a few. Production of H{sub 2} and CO is usually carried out by the following processes: Steam reforming (primary and secondary) of hydrocarbons, Partial oxidation of hydrocarbons, Coal gasification. Coal gasification and partial oxidation do not use catalysts and depend on partial combustion of the feedstock to internally supply reaction heat. Secondary (autothermal) reforming is a type of steam reforming that also uses the heat of partial combustion but afterwards uses a catalyst of promote the production of hydrogen and CO.

Wagner, E.S. (KTI Corp., San Dimas, CA (US)); Froment, G.F. (Ghent Rijksuniversiteit (Belgium))

1992-07-01T23:59:59.000Z

50

Downhole steam injector  

DOE Patents [OSTI]

An improved downhole steam injector has an angled water orifice to swirl the water through the device for improved heat transfer before it is converted to steam. The injector also has a sloped diameter reduction in the steam chamber to throw water that collects along the side of the chamber during slant drilling into the flame for conversion to steam. In addition, the output of the flame chamber is beveled to reduce hot spots and increase efficiency, and the fuel-oxidant inputs are arranged to minimize coking.

Donaldson, A. Burl (Albuquerque, NM); Hoke, Donald E. (Albuquerque, NM)

1983-01-01T23:59:59.000Z

51

Tips For Residential Heating Oil Tank Owners  

E-Print Network [OSTI]

路 路 路 路 路 路 路 路 路 路 路 路 路 路 路 路 路 路 路 路 路 路 Tips For Residential Heating Oil Tank Owners Source: DEP Fact Sheet Residential heating oil tanks are used to store fuel for furnaces or boilers to heat homes. The tanks can either be aboveground tanks, normally located in basements or utility rooms

Maroncelli, Mark

52

Options for Generating Steam Efficiently  

E-Print Network [OSTI]

This paper describes how plant engineers can efficiently generate steam when there are steam generators and Heat Recovery Steam Generators in their plant. The process consists of understanding the performance characteristics of the various equipment...

Ganapathy, V.

53

Steam Trap Management  

E-Print Network [OSTI]

A medium-sized plant of a high technology company is reaping the benefits of a Pro-active Steam Trap Program provided by Yarway's TECH/SERV Division. Initial work began March '84 and the most recent steam trap feasibility study conducted in March...

Murphy, J. J.; Hirtner, H. H.

54

Streams of Steam The Steam Boiler Specification Case Study  

E-Print Network [OSTI]

Streams of Steam 颅 The Steam Boiler Specification Case Study Manfred Broy, Franz Regensburger-tuned con- cepts of FOCUS by its application of the requirements specification of a steam boiler, see [Abr96-studies. In this context, applying FOCUS to the steam boiler case study ([Abr96]) led us to a couple of questions re- #12

55

Ukraine Steam Partnership  

SciTech Connect (OSTI)

The Ukraine Steam Partnership program is designed to implement energy efficiency improvements in industrial steam systems. These improvements are to be made by the private plants and local government departments responsible for generation and delivery of energy to end-users. One of the activities planned under this program was to provide a two-day training workshop on industrial steam systems focusing on energy efficiency issues related to the generation, distribution, and consumption of steam. The workshop was geared towards plant managers, who are not only technically oriented, but are also key decision makers in their respective companies. The Agency for Rational Energy Use and Ecology (ARENA-ECO), a non-governmental, not-for-profit organization founded to promote energy efficiency and environmental protection in Ukraine, in conjunction with the Alliance staff in Kiev sent out invitations to potential participants in all the regions of Ukraine. The purpose of this report is the describe the proceedings from the workshop and provide recommendations from the workshop's roundtable discussion. The workshop was broken down into two main areas: (1) Energy efficient boiler house steam generation; and Energy efficient steam distribution and consumption. The workshop also covered the following topics: (1) Ukrainian boilers; (2) Water treatment systems; (3) A profile of UKRESCO (Ukrainian Energy Services Company); (4) Turbine expanders and electricity generation; (5) Enterprise energy audit basics; and (6) Experience of steam use in Donetsk oblast.

Gurvinder Singh

2000-02-15T23:59:59.000Z

56

Steam trap monitor  

DOE Patents [OSTI]

A steam trap monitor positioned downstream of a steam trap in a closed steam system includes a first sensor (the combination of a hot finger and thermocouple well) for measuring the energy of condensate and a second sensor (a cold finger) for measuring the total energy of condensate and steam in the line. The hot finger includes one or more thermocouples for detecting condensate level and energy, while the cold finger contains a liquid with a lower boiling temperature than that of water. Vapor pressure from the liquid is used to do work such as displacing a piston or bellows in providing an indication of total energy (steam+condensate) of the system. Processing means coupled to and responsive to outputs from the thermocouple well hot and cold fingers subtracts the condensate energy as measured by the hot finger and thermocouple well from the total energy as measured by the cold finger to provide an indication of the presence of steam downstream from the trap indicating that the steam trap is malfunctioning.

Ryan, Michael J. (Plainfield, IL)

1988-01-01T23:59:59.000Z

57

Steam generator tube failures  

SciTech Connect (OSTI)

A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

1996-04-01T23:59:59.000Z

58

Refurbishing steam turbines  

SciTech Connect (OSTI)

Power-plant operators are reducing maintenance costs of their aging steam turbines by using wire-arc spray coating and shot peening to prolong the service life of components, and by replacing outmoded bearings and seals with newer designs. Steam-turbine operators are pressed with the challenge of keeping their aging machines functioning in the face of wear problems that are exacerbated by the demand for higher efficiencies. These problems include intense thermal cycling during both start-up and shutdown, water particles in steam and solid particles in the air that pit smooth surfaces, and load changes that cause metal fatigue.

Valenti, M.

1997-12-01T23:59:59.000Z

59

Evaluating Steam Trap Performance  

E-Print Network [OSTI]

~LmT " TRIf' 1 TRIf' 2 Figure 2 It has become common practice for engineers to oversize steam traps and place more emphasis on first cost than on maintenance cost and operating 766 3 4 ESL-IE-86-06-126 Proceedings from the Eighth Annual Industrial...EVALUATING STEAM TRAP PERFORMANCE Noel Y Fuller, P.E. Holston Defense Corporation Kingsport, Tennessee ABSTRACT Laboratory tests were conducted on several types of steam traps at Holston Defense Corporation in Kingsport, Tennessee. Data...

Fuller, N. Y.

60

Governmental-Owner Power Imbalance and Privatization  

E-Print Network [OSTI]

fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY Approved by: Chair of Committee, Laszlo Tihanyi Committee Members, Michael Hitt Lorraine Eden Allan (Haipeng) Chen Head of Department, Murray Barrick August 2010... Major Subject: Management iii ABSTRACT Governmental-Owner Power Imbalance and Privatization. (August 2010) Kehan Xu, B.S., China Criminal Police College; M.B.A., University of Miami Chair of Advisory Committee: Dr. Laszlo Tihanyi...

Xu, Kehan

2011-10-21T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Materials Performance in USC Steam  

SciTech Connect (OSTI)

Materials Performance in USC Steam: (1) pressure effects on steam oxidation - unique capability coming on-line; (2) hydrogen evolution - hydrogen permeability apparatus to determine where hydrogen goes during steam oxidation; and (3) NETL materials development - steam oxidation resource for NETL developed materials.

G. R. Holcomb; J. Tylczak; G. H. Meier; N. M. Yanar

2011-09-07T23:59:59.000Z

62

Steam Champions in Manufacturing  

E-Print Network [OSTI]

into equivalent corporate rewards, such as increased profitability, reliability, workplace safety, and other benefits. The prerequisites for becoming a true steam champion will include engineering, business, and management skills....

Russell, C.

63

Hog Fuel Drying Using Vapour Recompression  

E-Print Network [OSTI]

A continuous hog fuel drying pilot plant based on the principle of mixing hog fuel with a hot oil (e.g., crude tall oil) as the heat transfer medium, and recirculating the suspension through a steam heated exchanger was designed, built...

Azarniouch, M. K.; MacEachen, I.

1984-01-01T23:59:59.000Z

64

Steam System Tool Suite Introduction Guide  

E-Print Network [OSTI]

Steam System Tool Suite Introduction Guide Alternate Text Narratives and Graphic.............................................................................................................................6 Modules Steam System Scoping Tool (SSST)........................................................................................8 Steam System Assessment Tool (SSAT

Oak Ridge National Laboratory

65

Property:Owner | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar PowerstoriesNrelPartnerType Jump to: navigation, searchRelatedTo Jump to:Owner

66

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network [OSTI]

DOE's BestPractices Steam End User Training Steam End User Training Steam Distribution Losses Module 1 June 29, 2010 Steam EndUser Training Steam Distribution System Losses Module Slide 1 pressure. #12;DOE's BestPractices Steam End User Training Steam End User Training Steam Distribution

Oak Ridge National Laboratory

67

Overheating in Hot Water- and Steam-Heated Multifamily Buildings  

SciTech Connect (OSTI)

Apartment temperature data have been collected from the archives of companies that provide energy management systems (EMS) to multifamily buildings in the Northeast U.S. The data have been analyzed from more than 100 apartments in eighteen buildings where EMS systems were already installed to quantify the degree of overheating. This research attempts to answer the question, 'What is the magnitude of apartment overheating in multifamily buildings with central hot water or steam heat?' This report provides valuable information to researchers, utility program managers and building owners interested in controlling heating energy waste and improving resident comfort. Apartment temperature data were analyzed for deviation from a 70 degrees F desired setpoint and for variation by heating system type, apartment floor level and ambient conditions. The data shows that overheating is significant in these multifamily buildings with both hot water and steam heating systems.

Dentz, J.; Varshney, K.; Henderson, H.

2013-10-01T23:59:59.000Z

68

Steam Basics: Use Available Data to Lower Steam System Cost  

E-Print Network [OSTI]

Industrial steam users recognize the need to reduce system cost in order to remain internationally competitive. Steam systems are a key utility that influence cost significantly, and represent a high value opportunity target. However, the quality...

Risko, J. R.

2011-01-01T23:59:59.000Z

69

Optical wet steam monitor  

DOE Patents [OSTI]

A wet steam monitor determines steam particle size by using laser doppler velocimeter (LDV) device to produce backscatter light. The backscatter light signal is processed with a spectrum analyzer to produce a visibility waveform in the frequency domain. The visibility waveform includes a primary peak and a plurality of sidebands. The bandwidth of at least the primary frequency peak is correlated to particle size by either visually comparing the bandwidth to those of known particle sizes, or by digitizing the waveform and comparing the waveforms electronically. 4 figures.

Maxey, L.C.; Simpson, M.L.

1995-01-17T23:59:59.000Z

70

Steam Condensation Induced Waterhammer  

E-Print Network [OSTI]

,200 foot steam line to begin wanning it up. He'd been energizing the G-line for 3 weeks now at the end ofthe asbestos worker's shift and had never had the system warm up this quickly. It usually took from 30 to 45 minutes. When the handwheel spun... at Fort Wainwright, Alaska, the G and H Lines ran underground in narrow utilidors 2 filled with pipe. Originally, the contractor had tried to abate the steam main with the lines energized. This proved to be near impossible for the workers. Utilidor...

Kirsner, W.

71

Optical wet steam monitor  

DOE Patents [OSTI]

A wet steam monitor determines steam particle size by using laser doppler velocimeter (LDV) device to produce backscatter light. The backscatter light signal is processed with a spectrum analyzer to produce a visibility waveform in the frequency domain. The visibility waveform includes a primary peak and a plurality of sidebands. The bandwidth of at least the primary frequency peak is correlated to particle size by either visually comparing the bandwidth to those of known particle sizes, or by digitizing the waveform and comparing the waveforms electronically.

Maxey, Lonnie C. (Powell, TN); Simpson, Marc L. (Knoxville, TN)

1995-01-01T23:59:59.000Z

72

Visiting With Santa Fe Small Business Owners | Department of...  

Broader source: Energy.gov (indexed) [DOE]

you are a large or small business owner, learning the ins and outs of government contracting takes dedication, perseverance, and taking advantage of opportunities to meet...

73

CYBERSECURITY FUNDAMENTALS FOR SMALL BUSINESS OWNERS Shirley Radack, Editor  

E-Print Network [OSTI]

CYBERSECURITY FUNDAMENTALS FOR SMALL BUSINESS OWNERS Shirley Radack, Editor Computer Security and Technology (NIST) recently issued a new guide that tailors basic information on cybersecurity to the specific

74

Rights and Duties of Mines and Mine Owners, General (Missouri)  

Broader source: Energy.gov [DOE]

This legislation addresses general operational guidelines for mine owners regarding public notices, fees, land and mineral ownership, requirements for mining in certain municipalities, and mining...

75

Steam System Improvements at a Manufacturing Plant  

E-Print Network [OSTI]

BWX Technologies, Naval Nuclear Fuel Division (NNFD) is a manufacturing company with a steam system consisting of two Babcock & Wilcox boilers and approximately 350 steam traps. The steam system is used to produce and distribute steam for space...

Compher, J.; Morcom, B.

76

Steam generator tube rupture study  

E-Print Network [OSTI]

This report describes our investigation of steam generator behavior during a postulated tube rupture accident. Our study was performed using the steam generator, thermal-hydraulic analysis code THERMIT-UTSG. The purpose ...

Free, Scott Thomas

1986-01-01T23:59:59.000Z

77

Heat Recovery Steam Generator Simulation  

E-Print Network [OSTI]

The paper discusses the applications of Heat Recovery Steam Generator Simulation. Consultants, plant engineers and plant developers can evaluate the steam side performance of HRSGs and arrive at the optimum system which matches the needs...

Ganapathy, V.

78

Deaerators in Industrial Steam Systems  

SciTech Connect (OSTI)

This revised ITP tip sheet on deaerators in industrial steam systems provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

79

Reduction in Unit Steam Production  

E-Print Network [OSTI]

In 2001 the company's Arch-Brandenburg facility faced increased steam costs due to high natural gas prices and decreased production due to shutdown of a process. The facility was challenged to reduce unit steam consumption to minimize the effects...

Gombos, R.

2004-01-01T23:59:59.000Z

80

Belgrade Lot Steam Plant Lot  

E-Print Network [OSTI]

2 2A 2A Belgrade Lot Steam Plant Lot Alfond Lot Satellite Lot North Gym Lot Corbett Lot Dunn Lot Chadbourne Merrill Aubert Hannibal Hamlin Steam Plant Crosby Machine Tool Lab Children's Center Rogers N

Thomas, Andrew

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Belgrade Lot Steam Plant Lot  

E-Print Network [OSTI]

2 2A 2A Belgrade Lot Steam Plant Lot Alfond Lot Satellite Lot North Gym Lot Corbett Lot Dunn Lot Hamlin Steam Plant Crosby Machine Tool Lab Children's Center Rogers N S Estabrooke Memorial Gym Stevens

Thomas, Andrew

82

Economics of Steam Pressure Reduction  

E-Print Network [OSTI]

Economics of Steam Pressure Reduction is a technical paper that addresses the operating and economic advantages associated with the program to lower the steam operating pressure. Evaluation of a testing program will be discussed. The paper...

Sylva, D. M.

83

Inspect and Repair Steam Traps  

SciTech Connect (OSTI)

This revised ITP tip sheet on inspecting and repairing steam traps provide how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

84

Belgrade Lot Steam Plant Lot  

E-Print Network [OSTI]

2 2A 2A Belgrade Lot Steam Plant Lot Alfond Lot Satellite Lot North Gym Lot Gym Lot Corbett Lot Greenhouse Patch Oceanographic Operations 1 2 8 5 3 4 7 6 AMC Chadbourne Merrill Aubert Hannibal Hamlin Steam

Thomas, Andrew

85

Belgrade Lot Steam Plant Lot  

E-Print Network [OSTI]

2 2A 2A Belgrade Lot Steam Plant Lot Alfond Lot Satellite Lot North Gym Lot Corbett Lot Dunn Lot Oceanographic Operations 1 2 8 5 3 4 7 6 AMC Chadbourne Merrill Aubert Hannibal Hamlin Steam Plant Crosby

Thomas, Andrew

86

Measure Guideline: Steam System Balancing and Tuning for Multifamily Residential Buildings  

SciTech Connect (OSTI)

This report was written as a resource for professionals involved in multifamily audits, retrofit delivery, and program design, as well as for building owners and contractors. It is intended to serve as a guide for those looking to evaluate and improve the efficiency and operation of one-pipe steam heating systems. In centrally heated multifamily buildings with steam or hydronic systems, the cost of heat for tenants is typically absorbed into the owner's operating costs. Highly variable and rising energy costs have placed a heavy burden on landlords. In the absence of well-designed and relevant efficiency efforts, increased operating costs would be passed on to tenants who often cannot afford those increases. Misinvestment is a common problem with older heating systems -- multiple contractors may inadequately or inappropriately upgrade parts of systems and reduce system functionality and efficiency, or the system has not been properly maintained.

Choi, J.; Ludwig, P.; Brand, L.

2013-04-01T23:59:59.000Z

87

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network [OSTI]

DOE's BestPractices Steam End User Training Steam End User Training Steam Generation Efficiency Module Efficiency Definition - 1 8/30/2010 Steam End-User Training Steam Generation Efficiency Module Efficiency Definition Section Slide 1 - Steam Generation Efficiency Module This module will discuss steam

Oak Ridge National Laboratory

88

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network [OSTI]

DOE's BestPractices Steam End User Training Steam End User Training Steam Generation Efficiency Module Shell Losses - 1 8/27/2010 Steam End-User Training Steam Generation Efficiency Module Shell Losses-Section: Shell Losses] Banner: DOE's BestPractices Steam End User Training Steam Generation Efficiency Efficiency

Oak Ridge National Laboratory

89

Steam separator latch assembly  

DOE Patents [OSTI]

A latch assembly removably joins a steam separator assembly to a support flange disposed at a top end of a tubular shroud in a nuclear reactor pressure vessel. The assembly includes an annular head having a central portion for supporting the steam separator assembly thereon, and an annular head flange extending around a perimeter thereof for supporting the head to the support flange. A plurality of latches are circumferentially spaced apart around the head flange with each latch having a top end, a latch hook at a bottom end thereof, and a pivot support disposed at an intermediate portion therebetween and pivotally joined to the head flange. The latches are pivoted about the pivot supports for selectively engaging and disengaging the latch hooks with the support flange for fixedly joining the head to the shroud or for allowing removal thereof. 12 figures.

Challberg, R.C.; Kobsa, I.R.

1994-02-01T23:59:59.000Z

90

Steam separator latch assembly  

DOE Patents [OSTI]

A latch assembly removably joins a steam separator assembly to a support flange disposed at a top end of a tubular shroud in a nuclear reactor pressure vessel. The assembly includes an annular head having a central portion for supporting the steam separator assembly thereon, and an annular head flange extending around a perimeter thereof for supporting the head to the support flange. A plurality of latches are circumferentially spaced apart around the head flange with each latch having a top end, a latch hook at a bottom end thereof, and a pivot support disposed at an intermediate portion therebetween and pivotally joined to the head flange. The latches are pivoted about the pivot supports for selectively engaging and disengaging the latch hooks with the support flange for fixedly joining the head to the shroud or for allowing removal thereof.

Challberg, Roy C. (Livermore, CA); Kobsa, Irvin R. (San Jose, CA)

1994-01-01T23:59:59.000Z

91

Water cooled steam jet  

DOE Patents [OSTI]

A water cooled steam jet for transferring fluid and preventing vapor lock, or vaporization of the fluid being transferred, has a venturi nozzle and a cooling jacket. The venturi nozzle produces a high velocity flow which creates a vacuum to draw fluid from a source of fluid. The venturi nozzle has a converging section connected to a source of steam, a diffuser section attached to an outlet and a throat portion disposed therebetween. The cooling jacket surrounds the venturi nozzle and a suction tube through which the fluid is being drawn into the venturi nozzle. Coolant flows through the cooling jacket. The cooling jacket dissipates heat generated by the venturi nozzle to prevent vapor lock.

Wagner, Jr., Edward P. (Idaho Falls, ID)

1999-01-01T23:59:59.000Z

92

"Table HC3.7 Air-Conditioning Usage Indicators by Owner-Occupied...  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air-Conditioning Usage Indicators by Owner-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing...

93

Guide to Combined Heat and Power Systems for Boiler Owners and...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Guide to Combined Heat and Power Systems for Boiler Owners and Operators, July 2004 Guide to Combined Heat and Power Systems for Boiler Owners and Operators, July 2004 Many owners...

94

Saving Money with Steam Leak and Steam Trap Surveys  

E-Print Network [OSTI]

-sonic equipment. o Having uncorrected steam leaks and faulty traps cost your businesses time and money as well as being environmentally unfriendly. SERVICES ? Air Leak Surveys ? Nitrogen Leak Surveys ?Gas Leak Survey (H2, O2, Natural Gas) ? Steam Leak... productivity ? Processing efficiency ?Provide recommendations for improvement ?Stop profit loss by conserving wasted energy Undetected Steam leaks ? Rob efficiency in manufacturing and processing ? Lose millions of dollars annually ? Add up to very costly...

Woodruff, D.

2010-01-01T23:59:59.000Z

95

Steam condensate leakage  

SciTech Connect (OSTI)

Argonne National Laboratory (ANL) is a multi-program research and development center owned by the United States Department of Energy and operated by the University of Chicago. The majority of the buildings on site use steam for heating and other purposes. Steam is generated from liquid water at the site`s central boiler house and distributed around the site by means of large pipes both above and below the ground. Steam comes into each building where it is converted to liquid condensate, giving off heat which can be used by the building. The condensate is then pumped back to the boiler house where it will be reheated to steam again. The process is continual but is not perfectly efficient. A substantial amount of condensate is being lost somewhere on site. The lost condensate has both economic and environmental significance. To compensate for lost condensate, makeup water must be added to the returned condensate at the boiler house. The water cost itself will become significant in the future when ANL begins purchasing Lake Michigan water. In addition to the water cost, there is also the cost of chemically treating the water to remove impurities, and there is the cost of energy required to heat the water, as it enters the boiler house 1000 F colder than the condensate return. It has been estimated that only approximately 60% of ANL`s steam is being returned as condensate, thus 40% is being wasted. This is quite costly to ANL and will become significantly more costly in the future when ANL begins purchasing water from Lake Michigan. This study locates where condensate loss is occurring and shows how much money would be saved by repairing the areas of loss. Shortly after completion of the study, one of the major areas of loss was repaired. This paper discusses the basis for the study, the areas where losses are occurring, the potential savings of repairing the losses, and a hypothesis as to where the unaccounted for loss is occurring.

Midlock, E.B.; Thuot, J.R.

1996-07-01T23:59:59.000Z

96

Drying Foods at Home Safely Drying Herbs  

E-Print Network [OSTI]

jars, freezer bags, and airtight plastic containers. Like other foods dried at home, dried herbs in an airtight container and store in a cool, dry, and dark place. Recommended containers include glass canning

97

Guide to Combined Heat and Power Systems for Boiler Owners and...  

Broader source: Energy.gov (indexed) [DOE]

Combined Heat and Power Systems for Boiler Owners and Operators Guide to Combined Heat and Power Systems for Boiler Owners and Operators This guide presents useful information for...

98

Use a Vent Condenser to Recover Flash Steam Energy: Office of Industrial Technologies (OIT) Steam Energy Tips Fact Sheet  

SciTech Connect (OSTI)

BestPractices Steam tip sheet about using a vent condenser to recover flash steam energy in steam systems.

DOE Office of Industrial Technologies

2001-05-11T23:59:59.000Z

99

Steam Cracker Furnace Energy Improvements  

E-Print Network [OSTI]

Channel, ~ 25 mi. east of Houston ? Includes 4 manufacturing sites, 2 technology/engineering offices ?Significant community involvement Baytown Refinery Page 4 Steam Cracking to Olefins ? Process 60+ years old; ExxonMobil one of pioneers... Steam Cracker Furnace Energy Improvements Tim Gandler Energy Coordinator Baytown Olefins Plant, Baytown Tx 2010 Industrial Energy Technology Conference May, 2010 Page 2 ? Baytown Complex ? Steam Cracking to Olefins ? Furnace overview...

Gandler, T.

100

Steam System Forecasting and Management  

E-Print Network [OSTI]

by manipulation of operating schedules to avoid steam balances that result in steam venting, off gas-flaring, excessive condensing on extraction/condensing turbines, and ineffective use of extraction turbines. For example, during the fourth quarter of 1981... minimum turndown levels. Several boilers would have oeen shut down; by-product fuel gas would have been flared; and surplus low level steam would have been vented to the atmosphere. Several scenarios were studied with SFC and evaluated based...

Mongrue, D. M.; Wittke, D. O.

1982-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Process for purifying geothermal steam  

DOE Patents [OSTI]

Steam containing hydrogen sulfide is purified and sulfur recovered by passing the steam through a reactor packed with activated carbon in the presence of a stoichiometric amount of oxygen which oxidizes the hydrogen sulfide to elemental sulfur which is adsorbed on the bed. The carbon can be recycled after the sulfur has been recovered by vacuum distillation, inert gas entrainment or solvent extraction. The process is suitable for the purification of steam from geothermal sources which may also contain other noncondensable gases.

Li, Charles T. (Richland, WA)

1980-01-01T23:59:59.000Z

102

Air-cooled vacuum steam condenser  

SciTech Connect (OSTI)

This patent describes a steam powered system. It comprises: a turbine for converting steam energy into mechanical energy upon expansion of steam therein, a boiler for generating steam to be fed to the turbine, and a conduit arrangement coupling the boiler to the turbine and then recoupling the turbine exhaust to the boiler through steam condensing mechanisms.

Larinoff, M.W.

1990-02-27T23:59:59.000Z

103

Constant-Pressure Measurement of Steam-  

E-Print Network [OSTI]

SGP-TR-169 Constant-Pressure Measurement of Steam- Water Relative Permeability Peter A. O by measuring in-situ steam saturation more directly. Mobile steam mass fraction was established by separate steam and water inlets or by correlating with previous results. The measured steam-water relative

Stanford University

104

Steam Pressure Reduction: Opportunities and Issues; A BestPractices Steam Technical Brief  

SciTech Connect (OSTI)

A BestPractices Technical Brief describing industrial steam generation systems and opportunities for reducing steam system operating pressure.

Not Available

2005-11-01T23:59:59.000Z

105

Owner/contractor work structure process with integrated alignment framework  

E-Print Network [OSTI]

capital program expenditures , and to improve operational efficiency. For their capital projects, owners want the highest quality project, as fast as possible, at the lowest possible cost, with no harm to workers or the environment. To accomplish this...

Sullivan, George Ray

1996-01-01T23:59:59.000Z

106

MAINE MULTIFAMILY BUILDING OWNERS TRUST IN EFFICIENCY | Department...  

Broader source: Energy.gov (indexed) [DOE]

MAINE MULTIFAMILY BUILDING OWNERS TRUST IN EFFICIENCY Nearly 70% of households in Maine rely on fuel oil as their primary energy source for home heating, more than any other state....

107

Owner's Guide to Understanding Methods and Terms of Performance Contracting  

E-Print Network [OSTI]

for Proposal (RFP); Negotiation. The method of selection can greatly effect the success of the project. Owners seeking to improve their facilities through Performance Contracting should carefully consider the impact of the contracting method they select as well...

McDaniel, W.; Weaver, K.; Lacy, P.

1998-01-01T23:59:59.000Z

108

Steam Trap Application  

E-Print Network [OSTI]

~ ~ [EMPERATURE ~ -Surface pyrometer may indicate fluctuation due to expected in termittent discharge. -Blow down strainer, -Look for other leaks 5 ~e~7;~~rP~;i;~h~d~~:cer ~ l/month most process ~ l/week critical process ~ and air heaters in winter... valves must be -Small leaks undetected condensate & steam arf being trap line size -Electrical safety-some discharged simultaneorsly -Added cost of test tee,valves devices -Some devices need cal~bration en nipples, etc_ -Infra red devices nee~ cali- Z...

Murphy, J. J.

1982-01-01T23:59:59.000Z

109

Experimental and analytical studies of hydrocarbon yields under dry-, steam-, and steam with propane-distillation  

E-Print Network [OSTI]

from Instituto Mexicano del Petr髄eo (IMP), Dr. Fernando Rodriguez de la Garza, and Dr. Jose Luis Sanchez Bujanos from Petr髄eos Mexicanos (PEMEX), and Lawyer Rolando Rueda de Leon from Diario de Mexico, for their help and valuable advice. I would...

Ramirez Garnica, Marco Antonio

2004-09-30T23:59:59.000Z

110

DOE's BestPractices Steam End-User Training Steam End User Training  

E-Print Network [OSTI]

DOE's BestPractices Steam End-User Training Steam End User Training Steam Generation Module Stack Losses 1 June 28, 2010 Steam EndUser Training Steam Generation Efficiency Module Stack Losses loss is almost always the largest boiler loss. [Slide Visual 颅 Stack Loss Title Page] Steam

Oak Ridge National Laboratory

111

Steam System Improvement: A Case Study  

E-Print Network [OSTI]

. For industries, this will result in the reduction of production cost. In industry where steam is utilized, the steam production and distribution system consumes a significant portion of energy. Therefore, optimization of steam system is among the biggest energy...

Venkatesan, V. V.; Leigh, N.

112

ProSteam- A Structured Approach to Steam System Improvement  

E-Print Network [OSTI]

of the steam system could, therefore, be: ? To calculate the real cost of steam under various operational scenarios ? To identify current energy losses ? To accurately evaluate project savings ? To forecast future steam demand versus production... Energy Technology Conference, Houston, TX, April 16-19, 2002 Optimised System eff:85% 77.4MW eff:85% O.OMW 98 Uh 352'C 66 lIh eff:80% 68 lIh Max 100 Vh 18 lIh 80 lIh 50 'c 40 lIh 0.50 MW Po e Re ulrement 5 ba Ollh -0.6 barg Max 20 Vh...

Eastwood, A.

113

ULTRA-SUPERCRITICAL STEAM CORROSION  

SciTech Connect (OSTI)

Efficiency increases in fossil energy boilers and steam turbines are being achieved by increasing the temperature and pressure at the turbine inlets well beyond the critical point of water. To allow these increases, advanced materials are needed that are able to withstand the higher temperatures and pressures in terms of strength, creep, and oxidation resistance. As part of a larger collaborative effort, the Albany Research Center (ARC) is examining the steam-side oxidation behavior for ultrasupercritical (USC) steam turbine applications. Initial tests are being done on six alloys identified as candidates for USC steam boiler applications: ferritic alloy SAVE12, austenitic alloy Super 304H, the high Cr-high Ni alloy HR6W, and the nickel-base superalloys Inconel 617, Haynes 230, and Inconel 740. Each of these alloys has very high strength for its alloy type. Three types of experiments are planned: cyclic oxidation in air plus steam at atmospheric pressure, thermogravimetric ana lysis (TGA) in steam at atmospheric pressure, and exposure tests in supercritical steam up to 650 C (1202 F) and 34.5 MPa (5000 psi). The atmospheric pressure tests, combined with supercritical exposures at 13.8, 20.7, 24.6, and 34.5 MPa (2000, 3000, 4000, and 5000 psi) should allow the determination of the effect of pressure on the oxidation process.

Holcomb, G.R.; Alman, D.E.; Bullard, S.B.; Covino, B.S., Jr.; Cramer, S.D.; Ziomek-Moroz, M.

2003-04-22T23:59:59.000Z

114

GCFR steam generator conceptual design  

SciTech Connect (OSTI)

The gas-cooled fast reactor (GCFR) steam generators are large once-through heat exchangers with helically coiled tube bundles. In the GCFR demonstration plant, hot helium from the reactor core is passed through these units to produce superheated steam, which is used by the turbine generators to produce electrical power. The paper describes the conceptual design of the steam generator. The major components and functions of the design are addressed. The topics discussed are the configuration, operating conditions, design criteria, and the design verification and support programs.

Holm, R.A.; Elliott, J.P.

1980-01-01T23:59:59.000Z

115

Steam reformer with catalytic combustor  

DOE Patents [OSTI]

A steam reformer is disclosed having an annular steam reforming catalyst bed formed by concentric cylinders and having a catalytic combustor located at the center of the innermost cylinder. Fuel is fed into the interior of the catalytic combustor and air is directed at the top of the combustor, creating a catalytic reaction which provides sufficient heat so as to maintain the catalytic reaction in the steam reforming catalyst bed. Alternatively, air is fed into the interior of the catalytic combustor and a fuel mixture is directed at the top. The catalytic combustor provides enhanced radiant and convective heat transfer to the reformer catalyst bed.

Voecks, Gerald E. (La Crescenta, CA)

1990-03-20T23:59:59.000Z

116

Wet-steam erosion of steam turbine disks and shafts  

SciTech Connect (OSTI)

A study of wet-steam erosion of the disks and the rotor bosses or housings of turbines in thermal and nuclear power plants shows that the rate of wear does not depend on the diagrammed degree of moisture, but is determined by moisture condensing on the surfaces of the diaphragms and steam inlet components. Renovating the diaphragm seals as an assembly with condensate removal provides a manifold reduction in the erosion.

Averkina, N. V. [JSC 'NPO TsKTI' (Russian Federation); Zheleznyak, I. V. [Leningradskaya AES branch of JSC 'Kontsern Rosenergoatom' (Russian Federation); Kachuriner, Yu. Ya.; Nosovitskii, I. A.; Orlik, V. G., E-mail: orlikvg@mail.ru [JSC 'NPO TsKTI' (Russian Federation); Shishkin, V. I. [Leningradskaya AES branch of JSC 'Kontsern Rosenergoatom' (Russian Federation)

2011-01-15T23:59:59.000Z

117

Operational control and maintenance integrity of typical and atypical coil tube steam generating systems  

SciTech Connect (OSTI)

Coil tube steam generators are low water volume to boiler horsepower (bhp) rating, rapid steaming units which occupy substantially less space per boiler horsepower than equivalent conventional tire tube and water tube boilers. These units can be retrofitted into existing steam systems with relative ease and are more efficient than the generators they replace. During the early 1970's they became a popular choice for steam generation in commercial, institutional and light to medium industrial applications. Although these boiler designs do not require skilled or certified operators, an appreciation for a number of the operational conditions that result in lower unscheduled maintenance, increased reliability and availability cycles would be beneficial to facility owners, managers, and operators. Conditions which afford lower operating and maintenance costs will be discussed from a practical point of view. An overview of boiler design and operation is also included. Pitfalls are provided for operational and idle conditions. Water treatment application, as well as steam system operations not conducive to maintaining long term system integrity; with resolutions, will be addressed.

Beardwood, E.S.

1999-07-01T23:59:59.000Z

118

Combined Heat and Power Plant Steam Turbine  

E-Print Network [OSTI]

Combined Heat and Power Plant Steam Turbine Steam Turbine Chiller Campus Heat Load Steam (recovered waste heat) Gas Turbine University Substation High Pressure Natural Gas Campus Electric Load Southern Generator Heat Recovery Alternative Uses: 1. Campus heating load 2. Steam turbine chiller to campus cooling

Rose, Michael R.

119

Steam Load Reduction Guidance Emergency Management Program  

E-Print Network [OSTI]

Steam Load Reduction Guidance Emergency Management Program v October 2014 Steam_Load_Reduction_Guidance_DSRDSR 1.0 PurposeandScope Utilities provides steam to the campus community for space heating, hot water in the steam distribution system or the Central Energy Plant, the preservation of building infrastructure

Pawlowski, Wojtek

120

Steam-Powered Sensing Chengjie Zhang  

E-Print Network [OSTI]

Steam-Powered Sensing Chengjie Zhang 1 Affan Syed 1,2 Young Cho 1 John Heidemann 1 chengjie blockages in steam pipelines of a production oilfield. First, we eliminate the high cost of bringing power in steam pipelines and full blockages in hot water pipelines. Finally, we evaluate our "steam

Heidemann, John

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Steam Plant Conversion Eliminating Campus Coal Use  

E-Print Network [OSTI]

Steam Plant Conversion Eliminating Campus Coal Use at the Steam Plant #12; Flagship campus region produce 14% of US coal (TN only 0.2%) Knoxville and the TN Valley #12; UT is one of about 70 U.S. colleges and universities w/ steam plant that burns coal Constructed in 1964, provides steam for

Dai, Pengcheng

122

The Steam System Scoping Tool: Benchmarking Your Steam Operations Through Best Practices  

E-Print Network [OSTI]

system efficiency. The BestPractices Steam effort, a part of the DOE-OIT effort, has developed a new tool that steam energy managers and operations personnel can use to assess their steam operations and improve their steam energy usage -the Steam System...

Wright, A.; Hahn, G.

123

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network [OSTI]

DOE's BestPractices Steam End User Training Steam End User Training Welcome Module - 1 8/27/2010 Steam End User Training Welcome Module Slide 1 颅 Steam End User Training Welcome to the Department of Energy's Industrial Technologies Program BestPractices Steam End-User Training. The Department of Energy

Oak Ridge National Laboratory

124

DOE's BestPractices Steam End User Training Steam EndUser Training  

E-Print Network [OSTI]

DOE's BestPractices Steam End User Training Steam EndUser Training Resource Utilization. These include fuel selection, steam enduse or demand management, and combined heat and power activities importance of investigating steam enduse components and reducing steam consumption or improving the energy

Oak Ridge National Laboratory

125

The steam engine and industrialization  

E-Print Network [OSTI]

Simon Schaffer in York Rail Museum talks to the camera about the relationship between the steam engine and industrialization and whatsteam meant; a regular supply of moving power for workshops and factories....

Dugan, David

2004-08-17T23:59:59.000Z

126

Foam Cleaning of Steam Turbines  

E-Print Network [OSTI]

The efficiency and power output of a steam turbine can be dramatically reduced when deposits form on the turbine blades. Disassembly and mechanical cleaning of the turbine is very time consuming and costly. Deposits can be removed from the turbine...

Foster, C.; Curtis, G.; Horvath, J. W.

127

The Elimination of Steam Traps  

E-Print Network [OSTI]

claims and misinformation gener ated by over thirty-six steam trap manufacturers in the United States alone. A PARTIAL LIST OF STEAM TRAP MANUFACTURERS AAF GESTRA ANDERSON HIROSS ARMSTRONG HOFFMAN BARNES &JONES HONEYWELL BRAUKMANN BESTOBELL... removal had been devised and these same methods, with minor variations, are employed today. The inverted bucket trap was in vented in 1910 by Otto Arner, a friend of Adam Armstrong. Armstrong began his business career by making bicycle spokes...

Dickman, F.

128

Capturing Energy Savings with Steam Traps  

E-Print Network [OSTI]

Capturing Energy Savings with Steam Traps Richard C; Bockwinkel General Manager Armstrong Service? A Division of Armstrong International, Inc. Orlando, Florida ABSTRACT This paper will discuss the energy savings potential of steam... Engineer Steam Traps Armstrong International, Inc. Three Rivers, Michigan basis. Finally, it's important to recognize that a steam trap program will reduce steam waste> which will reduce the amount of fuel burned> which will reduce pollutants...

Bockwinkel, R. G.; French, S. A.

129

Development and Application of Advanced Models for Steam Hydrogasification: Process Design and Economic Evaluation  

E-Print Network [OSTI]

to make additional steam for the steam turbine cycle. Thein multi-pressure-level steam turbines to produce additionalthe superheated steam to the steam turbine cycle. The most

Lu, Xiaoming

2012-01-01T23:59:59.000Z

130

Dynamic underground stripping: steam and electric heating for in situ decontamination of soils and groundwater  

DOE Patents [OSTI]

A dynamic underground stripping process removes localized underground volatile organic compounds from heterogeneous soils and rock in a relatively short time. This method uses steam injection and electrical resistance heating to heat the contaminated underground area to increase the vapor pressure of the contaminants, thus speeding the process of contaminant removal and making the removal more complete. The injected steam passes through the more permeable sediments, distilling the organic contaminants, which are pumped to the surface. Large electrical currents are also applied to the contaminated area, which heat the impermeable subsurface layers that the steam has not penetrated. The condensed and vaporized contaminants are withdrawn by liquid pumping and vacuum extraction. The steam injection and electrical heating steps are repeated as necessary. Geophysical imaging methods can be used to map the boundary between the hot, dry, contamination-free underground zone and the cool, damp surrounding areas to help monitor the dynamic stripping process. 4 figs.

Daily, W.D.; Ramirez, A.L.; Newmark, R.L.; Udell, K.; Buetnner, H.M.; Aines, R.D.

1995-09-12T23:59:59.000Z

131

Dynamic underground stripping: steam and electric heating for in situ decontamination of soils and groundwater  

DOE Patents [OSTI]

A dynamic underground stripping process removes localized underground volatile organic compounds from heterogeneous soils and rock in a relatively short time. This method uses steam injection and electrical resistance heating to heat the contaminated underground area to increase the vapor pressure of the contaminants, thus speeding the process of contaminant removal and making the removal more complete. The injected steam passes through the more permeable sediments, distilling the organic contaminants, which are pumped to the surface. Large electrical currents are also applied to the contaminated area, which heat the impermeable subsurface layers that the steam has not penetrated. The condensed and vaporized contaminants are withdrawn by liquid pumping and vacuum extraction. The steam injection and electrical heating steps are repeated as necessary. Geophysical imaging methods can be used to map the boundary between the hot, dry, contamination-free underground zone and the cool, damp surrounding areas to help monitor the dynamic stripping process.

Daily, William D. (Livermore, CA); Ramirez, Abelardo L. (Pleasanton, CA); Newmark, Robin L. (Pleasanton, CA); Udell, Kent (Berkeley, CA); Buetnner, Harley M. (Livermore, CA); Aines, Roger D. (Livermore, CA)

1995-01-01T23:59:59.000Z

132

Use Steam Jet Ejectors or Thermocompressors to Reduce Venting of Low-Pressure Steam  

SciTech Connect (OSTI)

Industrial Technologies Program's BestPractices tip sheet on improving efficiency of industrial steam systems by recovery latent heat from low-pressure steam.

Not Available

2005-09-01T23:59:59.000Z

133

Evaluation of steam path audits  

SciTech Connect (OSTI)

Tri-State Generation and Transmission association is the operating agent for the 1350 megawatt Craig Generating Station, located in northwestern Colorado. Tri-State has recently incorporated turbine steam path audits into their aggressive performance improvement program. The intent of the audits are to quantify and attain the most cost effective increase in turbine performance as a result of a major outage. Valuable information about performance losses in the turbine has been obtained from steam path audits conducted on the three Craig Units. However, accurate audit results often depend on the quality of measurements and the experience of the auditor. Without a second method to verify the results of a steam path audit, repairs might be performed on a non-cost effective basis, or significant performance degradations might be overlooked. In addition, an inaccurate audit may lead to erroneous expectations for performance improvements resulting from the maintenance performed during the outage.

Caudill, M.B. [Tri-State Generation and Transmission Association, Inc., Montrose, CO (United States); Griebenow, R.D. [SAIC, Huntersville, NC (United States)

1995-06-01T23:59:59.000Z

134

"Greening" Industrial Steam Generation via On-demand Steam Systems  

E-Print Network [OSTI]

boiler technology currently in service in the U.S., it is critical to raise awareness and examine the role of emerging new technologies to address the energy and environmental challenges inherent with steam generation. In the same way that tank...

Smith, J. P.

2010-01-01T23:59:59.000Z

135

Lowest Pressure Steam Saves More BTU's Than You Think  

E-Print Network [OSTI]

ABSTRACT Steam is the most transferring heat from But most steam systems LOWEST PRESSURE STEAM SAVES MORE BTU'S THAN YOU THINK Stafford J. Vallery Armstrong Machine Works Three Rivers, Michigan steam to do the process heating rather than...

Vallery, S. J.

136

Use Steam Jet Ejectors or Thermocompressors to Reduce Venting...  

Broader source: Energy.gov (indexed) [DOE]

Steam Jet Ejectors or Thermocompressors to Reduce Venting of Low-Pressure Steam Use Steam Jet Ejectors or Thermocompressors to Reduce Venting of Low-Pressure Steam This tip sheet...

137

DOE BestPractices Steam End User Training  

E-Print Network [OSTI]

DOE BestPractices Steam End User Training Guide Alternate Text Narratives and Graphic Descriptions June 29, 2010 #12;DOE BestPractices Steam End User Training Steam End User Training Table ................................................................................................................................................................................................ 8 Technical Modules Steam Generation Efficiency Efficiency Definition

Oak Ridge National Laboratory

138

The steam engine and what it needs  

E-Print Network [OSTI]

Simon Schaffer explains that to produce an effective steam engine you do not just need specific inventions, such as the separate condenser of James Watt, but also skills from clockworking, distillation, metal working and so on. Then the steam power...

Dugan, David

2004-08-18T23:59:59.000Z

139

The Future of Steam: A Preliminary Discussion  

E-Print Network [OSTI]

Steam production represents a significant proportion of today's industrial energy demand. But the evolution of process technologies, as well as turbulence in energy markets, suggests that steam's role may be subject to change in the next decade...

Russell, C.; Harrell, G.; Moore, J.; French, S.

140

Insulate Steam Distribution and Condensate Return Lines  

SciTech Connect (OSTI)

This revised ITP tip sheet on insulating steam distribution and condensate return lines provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Steam Conservation and Boiler Plant Efficiency Advancements  

E-Print Network [OSTI]

This paper examines several cost-effective steam conservation and boiler plant efficiency advancements that were implemented during a recently completed central steam boiler plant replacement project at a very large semiconductor manufacturing...

Fiorino, D. P.

142

Training: Steam Systems | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Steam Systems Training: Steam Systems April 16, 2014 - 6:31pm Addthis Learn about the diverse training sessions offered. The courses are taught by highly qualified instructors who...

143

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network [OSTI]

DOE's BestPractices Steam End User Training Steam End User Training Navigational Tutorial - 1 8/27/2010 Steam End User Training Navigational Tutorial Module Slide 1 颅 Introduction Hello, and welcome to the Steam End User Training. I would like to take a few minutes to show you how to navigate through

Oak Ridge National Laboratory

144

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network [OSTI]

DOE's BestPractices Steam End User Training Steam End User Training Introduction Module - 1 8/27/2010 Steam End User Training Introduction Module Slide 1 - Introduction Title Page Hello, and welcome to the Steam System End User training. In this training, we will investigate how to assess, evaluate

Oak Ridge National Laboratory

145

Optimisation of Fuel Usage and Steam Availability in the Power and Steam  

E-Print Network [OSTI]

Optimisation of Fuel Usage and Steam Availability in the Power and Steam Plant of a Paper Mill KEYWORDS: Model Predictive Control, Improved Efficiency, Optimisation, Power and Steam Supply System ABSTRACT This paper presents the results of a project aimed at minimising fuel usage while maximising steam

Cambridge, University of

146

Low pressure combustor for generating steam downhole  

SciTech Connect (OSTI)

A compact catalytic combustor for generating steam downhole in an oil reservoir has steam generating tubes that are attached to a metal catalyst support. The metal support comprises sheets of metal that are spaced apart and transverse to the tubes. Heat from combustion is generated on the metal sheets and is conducted to the steam generating tubes. The steam is injected into the oil reservoir. The combustion gas is vented to ground level.

Retallick, W.B.

1983-03-22T23:59:59.000Z

147

Best Management Practice #8: Steam Boiler Systems  

Broader source: Energy.gov [DOE]

Boilers and steam generators are commonly used in large heating systems, institutional kitchens, or in facilities where large amounts of process steam are used. This equipment consumes varying amounts of water depending on system size, the amount of steam used, and the amount of condensate returned.

148

Steam System Improvement: A Case Study  

E-Print Network [OSTI]

usage) where steam generation accounts for 85% of the total energy used. Therefore, optimization of the steam system has the biggest energy saving potential. This paper mill produces 40,000 pounds of steam at 600 psig and distributes it to the paper...

Leigh, N.; Venkatesan, V. V.

149

A LABORATORY INVESTIGATION OF STEAM ADSORPTION  

E-Print Network [OSTI]

A LABORATORY INVESTIGATION OF STEAM ADSORPTION IN GEOTHERMAL RESERVOIR ROCKS OF STANFORD UNIVERSITY, if any, liquid. Yet to satisfy material bal- ance constraints, another phase besides steam must be present. If steam adsorption occurring in significant amounts is not accounted for, the reserves

Stanford University

150

STEAM-WATER RELATIVE PERMEABILITY A DISSERTATION  

E-Print Network [OSTI]

STEAM-WATER RELATIVE PERMEABILITY A DISSERTATION SUBMITTED TO THE DEPARTMENT OF PETROLEUM Laboratory. iv #12;ABSTRACT Steam-water relative permeability curves are required for mathematical models of two-phase geothermal reservoirs. In this study, drainage steam- water relative permeabilities were

Stanford University

151

Steam Sterilization Cycles for Lab Applications  

E-Print Network [OSTI]

Steam Sterilization Cycles for Lab Applications Presented by Gary Butler STERIS Life Sciences August 2009 #12;Early Steam Sterilizers Koch Upright Sterilizer 路 First Pressurized Sterilizer 路 First OPERATING END (NO PRINTER) PRIMARY OPERATING END WITH PRINTER SAFETY VALVE CHAMBER PRESSURE GAUGE Steam

Farritor, Shane

152

Recover heat from steam reforming  

SciTech Connect (OSTI)

Steam reforming is one of the most important chemical processes--it is used in the manufacture of ammonia, hydrogen, methanol, and many chemicals made from hydrogen and carbon monoxide. Furthermore, many current trends will increase its importance. For example, methanol for addition to gasoline is likely to be produced by steam reforming. Because steam reforming occurs at high temperatures--typically 750 C--900 C--it generates a large amount of waste heat. Clearly, heat recovery is crucial to process economics. A typical 50,000 Nm[sup 3]/h hydrogen plant using natural gas feed has a radiant heat duty of about 50 MW. At a radiant efficiency of 50% and fuel cost of $3/GJ, this means that the reformer fires $9 million worth of fuel per year. Obviously, this amount of fuel justifies a close loot at ways to reduce costs. This article first provides a brief overview of steam reforming. It then outlines the available heat-recovery options and explains how to select the best method.

Fleshman, J.D. (Foster Wheeler USA Corp., Livingston, NJ (United States))

1993-10-01T23:59:59.000Z

153

Generating Steam by Waste Incineration  

E-Print Network [OSTI]

Combustible waste is a significant source of steam at the new John Deere Tractor Works assembly plant in Waterloo, Iowa. The incinerators, each rated to consume two tons of solid waste per hour, are expected to provide up to 100 percent of the full...

Williams, D. R.; Darrow, L. A.

1981-01-01T23:59:59.000Z

154

Materials Performance in USC Steam  

SciTech Connect (OSTI)

The proposed steam inlet temperature in the Advanced Ultra Supercritical (A-USC) steam turbine is high enough (760 癈) that traditional turbine casing and valve body materials such as ferritic/martensitic steels will not suffice due to temperature limitations of this class of materials. Cast versions of several traditionally wrought Ni-based superalloys were evaluated for use as casing or valve components for the next generation of industrial steam turbines. The full size castings are substantial: 2-5,000 kg each half and on the order of 100 cm thick. Experimental castings were quite a bit smaller, but section size was retained and cooling rate controlled to produce equivalent microstructures. A multi-step homogenization heat treatment was developed to better deploy the alloy constituents. The most successful of these cast alloys in terms of creep strength (Haynes 263, Haynes 282, and Nimonic 105) were subsequently evaluated by characterizing their microstructure as well as their steam oxidation resistance (at 760 and 800 癈).

G. R. Holcomb, P. Wang, P. D. Jablonski, and J. A. Hawk

2010-05-01T23:59:59.000Z

155

Plant View On Reducing Steam Trap Energy Loss  

E-Print Network [OSTI]

of the steam traps are passing excess steam. This is caused by neglect of aged steam traps which have worn out and misapplication of steam traps by oversizing or using the 'wrong' type trap. Elimination of steam wastes by an effective well engineered steam trap...

Vallery, S. J.

1982-01-01T23:59:59.000Z

156

Steam Pressure Reduction Opportunities and Issues  

E-Print Network [OSTI]

Parameter Baseline System (130 psig) (klb/h) % of Steam Produced Reduced Pressure (80 psig) (klb/h) % of Steam Produced Savings (klb/h) Steam generation 40.8 40.3 0.5 High pressure steam consumption 12.5 30.64 12.2 30.27 0.3 Low... the operating pressure is reached (3). The amount of fuel consumed is reduced while still meeting the required need for thermal energy. This fuel reduction can be estimated using the U.S. Department of Energy (DOE) BestPractices Steam System Assessment Tool...

Berry, J.; Griffin, B.; Wright, A. L.

2006-01-01T23:59:59.000Z

157

Steam cooling system for a gas turbine  

DOE Patents [OSTI]

The steam cooling circuit for a gas turbine includes a bore tube assembly supplying steam to circumferentially spaced radial tubes coupled to supply elbows for transitioning the radial steam flow in an axial direction along steam supply tubes adjacent the rim of the rotor. The supply tubes supply steam to circumferentially spaced manifold segments located on the aft side of the 1-2 spacer for supplying steam to the buckets of the first and second stages. Spent return steam from these buckets flows to a plurality of circumferentially spaced return manifold segments disposed on the forward face of the 1-2 spacer. Crossover tubes couple the steam supply from the steam supply manifold segments through the 1-2 spacer to the buckets of the first stage. Crossover tubes through the 1-2 spacer also return steam from the buckets of the second stage to the return manifold segments. Axially extending return tubes convey spent cooling steam from the return manifold segments to radial tubes via return elbows.

Wilson, Ian David (Mauldin, SC); Barb, Kevin Joseph (Halfmoon, NY); Li, Ming Cheng (Cincinnati, OH); Hyde, Susan Marie (Schenectady, NY); Mashey, Thomas Charles (Coxsackie, NY); Wesorick, Ronald Richard (Albany, NY); Glynn, Christopher Charles (Hamilton, OH); Hemsworth, Martin C. (Cincinnati, OH)

2002-01-01T23:59:59.000Z

158

Air-cooled vacuum steam condenser  

SciTech Connect (OSTI)

This patent describes a steam powered system. It comprises: a turbine for converting steam energy into mechanical energy upon expansion of steam therein, a boiler for generating steam to be fed to the turbine, and a conduit arrangement coupling the boiler to the turbine and then recoupling the turbine exhaust to the boiler through steam condensing mechanisms. The condensing mechanisms including: a plurality of finned tubes through which the expanded exhaust steam flows and is condensed; a plurality of bundle from headers at the lower ends of the condensing tubes for receiving exhaust steam from the turbine; a plurality of bundle divided rear headers, one for each tube row in the bundle, at the higher ends of the condensing tubes for receiving non-condensible gases; and means in the rear and last headers to remove non-condensible gasses from the rear headers along their full length.

Larinoff, M.W.

1990-03-06T23:59:59.000Z

159

Enhancing fire safety at Hydro plants with dry transformers  

SciTech Connect (OSTI)

Hydroelectric plant owners and engineers can use dry-type transformers to reduce fire hazards in auxiliary power systems. The decision to replace a liquid-immersed transformer with a dry-type product has a price: higher unit cost and a need to be more vigilant in detailing transformer specifications. But, whether the change affects only one failed transformer or is part of a plant rehabilitation project, the benefits in safety can be worth it. Voltages on hydroelectric plant auxiliary power systems can range from a 20 kV medium-voltage system to the normal 480-208/120 V low-voltage system. Dry transformers typically are used in such systems to reduce the fire hazard present with liquid-filled transformers. For a hydro plant owner or engineer seeking alternatives to liquid-filled transformers, there are two main kinds of dry-type transformers to consider: vacuum pressure impregnated (VPI) and cast coil epoxy resin. VPI transformers normally are manufactured in sizes up to 6,000 kVA with primary voltage ratings up to 20 kV. Cast coil transformers can be made in sizes from 75 to 10,000 kVA, with primary voltage ratings up to 34,500 V. Although the same transformer theory applies to dry transformers as to liquid-filled units, the cooling medium, air, required different temperature rise ratings, dielectric tests, and construction techniques to ensure reliability. Consequently, the factory and field tests for dry units are established by a separate set of American National Standards Institute (ANSI)/Institute of Electrical and Electronics Engineers (IEEE) standards. Cast coil transformers have several important advantages over VPI units.

Clemen, D.M. (Harza Engineering Company, Chicago, IL (United States))

1993-06-01T23:59:59.000Z

160

Guide to Combined Heat and Power Systems for Boiler Owners and Operators  

SciTech Connect (OSTI)

Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as conventional power plants that only generate electricity and industrial boiler systems that only produce steam or hot water for process applications. By using fuel energy for both power and heat production, CHP systems can be very energy efficient and have the potential to produce electricity below the price charged by the local power provider. Another important incentive for applying cogeneration technology is to reduce or eliminate dependency on the electrical grid. For some industrial processes, the consequences of losing power for even a short period of time are unacceptable. The primary objective of the guide is to present information needed to evaluate the viability of cogeneration for new or existing industrial, commercial, and institutional (ICI) boiler installations and to make informed CHP equipment selection decisions. Information presented is meant to help boiler owners and operators understand the potential benefits derived from implementing a CHP project and recognize opportunities for successful application of cogeneration technology. Topics covered in the guide follow: (1) an overview of cogeneration technology with discussions about benefits of applying cogeneration technology and barriers to implementing cogeneration technology; (2) applicable federal regulations and permitting issues; (3) descriptions of prime movers commonly used in CHP applications, including discussions about design characteristics, heat-recovery options and equipment, fuels and emissions, efficiency, maintenance, availability, and capital cost; (4) electrical generators and electrical interconnection equipment; (5) cooling and dehumidification equipment; (6) thermodynamic cycle options and configurations; (7) steps for evaluating the technical and economic feasibility of applying cogeneration technology; and (8) information sources.

Oland, CB

2004-08-19T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Hydrogen production by high-temperature steam gasification of biomass and coal  

SciTech Connect (OSTI)

High-temperature steam gasification of paper, yellow pine woodchips, and Pittsburgh bituminous coal was investigated in a batch-type flow reactor at temperatures in the range of 700 to 1,200{sup o}C at two different ratios of steam to feedstock molar ratios. Hydrogen yield of 54.7% for paper, 60.2% for woodchips, and 57.8% for coal was achieved on a dry basis, with a steam flow rate of 6.3 g/min at steam temperature of 1,200{sup o}C. Yield of both the hydrogen and carbon monoxide increased while carbon dioxide and methane decreased with the increase in gasification temperature. A 10-fold reduction in tar residue was obtained at high-temperature steam gasification, compared to low temperatures. Steam and gasification temperature affects the composition of the syngas produced. Higher steam-to-feedstock molar ratio had negligible effect on the amount of hydrogen produced in the syngas in the fixed-batch type of reactor. Gasification temperature can be used to control the amounts of hydrogen or methane produced from the gasification process. This also provides mean to control the ratio of hydrogen to CO in the syngas, which can then be processed to produce liquid hydrocarbon fuel since the liquid fuel production requires an optimum ratio between hydrogen and CO. The syngas produced can be further processed to produce pure hydrogen. Biomass fuels are good source of renewable fuels to produce hydrogen or liquid fuels using controlled steam gasification.

Kriengsak, S.N.; Buczynski, R.; Gmurczyk, J.; Gupta, A.K. [University of Maryland, College Park, MD (United States). Dept. of Mechanical Engineering

2009-04-15T23:59:59.000Z

162

Steam Turbine Materials and Corrosion  

SciTech Connect (OSTI)

Ultra-supercritical (USC) power plants offer the promise of higher efficiencies and lower emissions. Current goals of the U.S. Department of Energy抯 Advanced Power Systems Initiatives include coal generation at 60% efficiency, which would require steam temperatures of up to 760 癈. In prior years this project examined the steamside oxidation of alloys for use in high- and intermediate-pressure USC turbines. This steamside oxidation research is continuing and progress is presented, with emphasis on chromia evaporation.

Holcomb, G.H.; Hsu, D.H.

2008-07-01T23:59:59.000Z

163

Cooling Dry Cows  

E-Print Network [OSTI]

This publication discusses the effects of heat stress on dairy cows, methods of cooling cows, and research on the effects of cooling cows in the dry period....

Stokes, Sandra R.

2000-07-17T23:59:59.000Z

164

Cooking with Dried Potatoes  

E-Print Network [OSTI]

This fact sheet describes the nutritional value and safe storage of dried potatoes, a commodity food. It also offers food preparation ideas....

Anding, Jenna

2008-12-09T23:59:59.000Z

165

Use Steam Jet Ejectors or Thermocompressors to Reduce Venting of Low-Pressure Steam  

SciTech Connect (OSTI)

This revised ITP tip sheet on steam jet ejectors and thermocompressors provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

166

Identifying Steam Opportunity "Impact" Inputs for the Steam System Assessment Tool (SSAT)  

E-Print Network [OSTI]

IDENTIFYING STEAM OPPORTUNITY "IMPACT" INPUTS FOR THE STEAM SYSTEM ASSESSMENT TOOL (SSAT) Dr. Greg Harrell, University of Tennessee/Knoxville Dr. Richard Jendrucko, University of Tennessee/Knoxville Dr. Anthony Wright, Oak Ridge National...

Harrell, G.; Jendrucko, R.; Wright, A.

2004-01-01T23:59:59.000Z

167

The Steam System Assessment Tool (SSAT): Estimating Steam System Energy, Cost, and Emission Savings  

E-Print Network [OSTI]

The U. S. Department of Energy's (DOE) Industrial Technology Program BestPractices Steam effort is developing a number of software tools to assist industrial energy users to improve the efficiency of their steam system. A major new Best...

Wright, A.; Bealing, C.; Eastwood, A.; Tainsh, R.; Hahn, G.; Harrell, G.

168

Energy Savings Through Steam Trap Management  

E-Print Network [OSTI]

Energy Savings through Steam Trap Management Chris Gibbs, Account Manager, Armstrong International, Inc., Three Rivers, MI ESL-IE-08-05-08 Proceedings from theThirtieth Industrial Energy Technology Conference...-based steam trap management application developed by Armstrong International. The application calculates steam loss, fuel loss, dollar loss and CO 2 emission generation. The database allows for trend analysis, automatic energy report generation...

Gibbs, C.

2008-01-01T23:59:59.000Z

169

Electrical Cost Reduction Via Steam Turbine Cogeneration  

E-Print Network [OSTI]

ELECTRICAL COST REDUCTION VIA STEAM TURBINE COGENERATION LYNN B. DI TULLIO, P.E. Project Engineer Ewing Power Systems, Inc. South Deerfield, Mass. ABSTRACT Steam turbine cogeneration is a well established technology which is widely used... mature technology. Steam turbines and engines have been used by industry to cogen erate power since before there were electric utilities. While the technology for turbines, generators and controls has continued to develop there is very little about...

Ewing, T. S.; Di Tullio, L. B.

170

Steam reforming utilizing high activity catalyst  

SciTech Connect (OSTI)

High activity, sulfur tolerant steam reforming catalysts are described comprising rhodium or nickel supported on lanthanum stabilized alumina or magnesium promoted lanthanum stabilized alumina. The catalysts have improved activity over conventionally used catalysts in the presence of sulfur containing hydrocarbon fuel (such as No. 2 fuel oil) in a steam reforming environment. The material has particular utility in autothermal, tubular, cyclic and adiabatic steam reforming processes.

Setzer, H. J.

1985-03-05T23:59:59.000Z

171

Method of steam reforming methanol to hydrogen  

DOE Patents [OSTI]

The production of hydrogen by the catalyzed steam reforming of methanol is accomplished using a reformer of greatly reduced size and cost wherein a mixture of water and methanol is superheated to the gaseous state at temperatures of about 800.degree. to about 1,100.degree. F. and then fed to a reformer in direct contact with the catalyst bed contained therein, whereby the heat for the endothermic steam reforming reaction is derived directly from the superheated steam/methanol mixture.

Beshty, Bahjat S. (Lower Makefield, PA)

1990-01-01T23:59:59.000Z

172

World launch! Hot-Steam Aerostat  

E-Print Network [OSTI]

Info HeiDAS UH World launch! Hot-Steam Aerostat #12;"If you intend to view the land, if you plan Verne: "Fife weeks on a balloon". HeiDAS stands for Hei?DampfAeroStat (Hot-Steam AeroStat) and it refers to the first operable balloon ever that became buoyant by means of superheated steam. The performance of Hei

Berlin,Technische Universit盲t

173

Proceedings of design, repair, and refurbishment of steam turbines  

SciTech Connect (OSTI)

This book reports on the proceedings of design, repair and refurbishment of steam engines. Topics covered include: Advisor/Expert Systems for Steam Turbines; Moisture Effects on the Operating and Performance of Steam Turbines; Turbine Steam Path Development; Repair and Refurbishment of the Electric Generator Components; and Advanced Steam Turbine Designs.

Warnock, A.S. (Lehigh Univ., PA (United States))

1991-01-01T23:59:59.000Z

174

Industrial Heat Pumps for Steam and Fuel Savings: A BestPractices Steam Technical Brief  

SciTech Connect (OSTI)

The purpose of this Steam Techcial Brief is to introduce heat-pump technology and its applicaiton in industrial processes.

Not Available

2003-06-01T23:59:59.000Z

175

Efficiently generate steam from cogeneration plants  

SciTech Connect (OSTI)

As cogeneration gets more popular, some plants have two choices of equipment for generating steam. Plant engineers need to have a decision chart to split the duty efficiently between (oil-fired or gas-fired) steam generators (SGs) and heat recovery steam generators (HRSGs) using the exhaust from gas turbines. Underlying the dilemma is that the load-versus-efficiency characteristics of both types of equipment are different. When the limitations of each type of equipment and its capability are considered, analysis can come up with several selection possibilities. It is almost always more efficient to generate steam in an HRSG (designed for firing) as compared with conventional steam generators. However, other aspects, such as maintenance, availability of personnel, equipment limitations and operating costs, should also be considered before making a final decision. Loading each type of equipment differently also affects the overall efficiency or the fuel consumption. This article describes the performance aspects of representative steam generators and gas turbine HRSGs and suggests how plant engineers can generate steam efficiently. It also illustrates how to construct a decision chart for a typical installation. The equipment was picked arbitrarily to show the method. The natural gas fired steam generator has a maximum capacity of 100,000 lb/h, 400-psig saturated steam, and the gas-turbine-exhaust HRSG has the same capacity. It is designed for supplementary firing with natural gas.

Ganapathy, V. [ABCO Industries, Abilene, TX (United States)

1997-05-01T23:59:59.000Z

176

Covered Product Category: Commercial Steam Cookers  

Broader source: Energy.gov [DOE]

The Federal Energy Management Program (FEMP) provides acquisition guidance for commercial steam cookers, which are covered by the ENERGY STAR program.

177

Save Energy Now in Your Steam Systems  

SciTech Connect (OSTI)

This DOE Industrial Technologies Program fact sheet describes how manufacturing plants can save energy and money by making energy efficiency improvements to their industrial steam systems.

Not Available

2006-01-01T23:59:59.000Z

178

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network [OSTI]

DOE's BestPractices Steam End User Training Steam End User Training Conclusion Module 1 June 28, 2010 Steam EndUser Training Conclusion Module Slide 1 Conclusions Let's briefly examine the major items we have covered in this training. [Slide Visual 颅 Contents of Module Sections

Oak Ridge National Laboratory

179

Steam catalysis in CaO carbonation under low steam partial pressure  

SciTech Connect (OSTI)

CaO was widely used to capture CO{sub 2} in direct hydrogen production process, where steam always existed simultaneously. The effect of steam on CaO carbonation performance under low steam partial pressure was investigated using a pressurized thermogravimetric apparatus. The experimental results revealed that steam improved CaO carbonation performance significantly no matter whether Ca(OH){sub 2} was produced or not. At 823 K and 0.5 MPa of steam partial pressure, effect of steam on CaO carbonation performance could not be attributed mainly to production of Ca(OH){sub 2} because the hydration rate of CaO was very slow. The main reason was steam catalysis in CaO carbonation. Enhancement of steam on CaO carbonation performance without Ca(OH){sub 2} production could not be attributed to improvement of steam on the physical property, but to catalytic effect of steam. Effects of CaO precursors, CO{sub 2} partial pressure, steam partial pressure, and temperature with steam addition on CaO carbonation performance were also investigated.

Yang, S.J.; Xiao, Y.H. [Chinese Academy of Science, Beijing (China)

2008-06-15T23:59:59.000Z

180

Geismar TDI Plant Steam Optimization  

E-Print Network [OSTI]

BASF North America 7 ESL-IE-13-05-19 Proceedings of the Thrity-Fifth Industrial Energy Technology Conference New Orleans, LA. May 21-24, 2013 BASF?s strategic principles A conscientious commitment to our investors, customers, employees...Geismar TDI Plant Steam Optimization May 23rd, 2013 IET Conference Meredith Bailey, PDP Engineer BASF Corporation (734) 324-5047 meredith.bailey@basf.com ESL-IE-13-05-19 Proceedings of the Thrity-Fifth Industrial Energy Technology...

Baily, M.

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Designing an ultrasupercritical steam turbine  

SciTech Connect (OSTI)

Carbon emissions produced by the combustion of coal may be collected and stored in the future, but a better approach is to reduce the carbon produced through efficient combustion technologies. Increasing the efficiency of new plants using ultrasupercritical (USC) technology will net less carbon released per megawatt-hour using the world's abundant coal reserves while producing electricity at the lowest possible cost. The article shows how increasing the steam turbine operating conditions for a new USC project in the USA and quantify the potential CO{sub 2} reduction this advanced design makes possible. 7 figs., 3 tabs.

Klotz, H.; Davis, K.; Pickering, E. [Alstom (Germany)

2009-07-15T23:59:59.000Z

182

Steam Systems | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: AlternativeEnvironment,Institutes and1 Special Report: OAS-RA-14-01AwardsStateStatesAboutSteam

183

Steam Coal Import Costs - EIA  

Gasoline and Diesel Fuel Update (EIA)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines About U.S. NaturalA. Michael Schaal Director, Oil and10:InformationSteam Coal Import

184

Energy Input and Quality of Pellets Made from Steam-Exploded Douglas Fir (Pseudotsuga menziesii)  

SciTech Connect (OSTI)

Ground softwood Douglas fir (Pseudotsuga menziesii) was treated with pressurized saturated steam at 200-220 C (1.6-2.4 MPa) for 5-10 min in a sealed container. The contents of the container were released to the atmosphere for a sudden decompression. The steam-exploded wood particles were dried to 10% moisture content and pelletized in a single-piston-cylinder system. The pellets were characterized for their mechanical strength, chemical composition, and moisture sorption. The steamtreated wood required 12-81% more energy to compact into pellets than the untreated wood. Pellets made from steam-treated wood had a breaking strength 1.4-3.3 times the strength of pellets made from untreated wood. Steam-treated pellets had a reduced equilibrium moisture content of 2-4% and a reduced expansion after pelletization. There was a slight increase in the high heating value from 18.94 to 20.09 MJ/kg for the treated samples. Steam-treated pellets exhibited a higher lengthwise rigidity compared to untreated pellets.

Sokhansanj, Shahabaddine [ORNL; Bi, X.T. [University of British Columbia, Vancouver; Lim, C. Jim [University of British Columbia, Vancouver; Melin, Staffan [University of British Columbia, Vancouver

2011-01-01T23:59:59.000Z

185

Effective Steam Trap Selection/Maintenance - Its Payback  

E-Print Network [OSTI]

In oil refineries and petrochemical plants large number of steam traps are used to discharge condensate from steam mains, tracers and process equipment. Early efforts on steam traps focused almost exclusively on their selection and sizing...

Garcia, E.

1984-01-01T23:59:59.000Z

186

Preliminary Results from the Industrial Steam System Market Assessment  

E-Print Network [OSTI]

This paper discusses fuel use and potential energy savings in the steam systems of three steam intensive industries: pulp and paper, chemical manufacturing, and petroleum refining. To determine the energy consumption to generate steam...

McGrath, G. P.; Wright, A. L.

187

Steam turbine materials and corrosion  

SciTech Connect (OSTI)

Ultra supercritical (USC) power plants offer the promise of higher efficiencies and lower emissions. Current goals of the U.S. Department of Energy抯 Advanced Power Systems Initiatives include coal generation at 60% efficiency, which would require steam temperatures of up to 760癈. This research examines the steamside oxidation of alloys for use in USC systems, with emphasis placed on applications in high- and intermediate-pressure turbines. The list of alloys being examined is discussed, including the addition of new alloys to the study. These include alloy 625, selected because of its use as one of the two alloys used for turbine rotors, valves, casings, blading and bolts in the European AD700 full-scale demonstration plant (Scholven Unit F). The other alloy, alloy 617, is already one of the alloys currently being examined by this project. Other new alloys to the study are the three round robin alloys in the UK-US collaboration: alloys 740, TP347HFG, and T92. Progress on the project is presented on cyclic oxidation in 50% air 50% water vapor, furnace exposures in moist air, and thermogravimetric analysis in argon with oxygen saturated steam. An update on the progress towards obtaining an apparatus for high pressure exposures is given.

Holcomb, G.R.; Ziomek-Moroz, M.

2007-01-01T23:59:59.000Z

188

Energy Management - Using Steam Pressure Efficiently  

E-Print Network [OSTI]

Saturated steam contains heat in two different forms. Sensible heat and latent heat. Due to the nature of this vapor, the relative proportion of latent heat is higher at lower pressures compared to higher pressures. When steam is used for heating...

Jiandani, N.

1983-01-01T23:59:59.000Z

189

Steam System Optimization: A Case Study  

E-Print Network [OSTI]

This paper highlights the study findings in a steam system in a plant from a multinational Petrochemical giant in an European country. The steam system operates with an annual budget of $8.9 million (local currency was converted to US Dollars...

Iordanova, N.; Venkatesan, V. V.

190

Optimized Control Of Steam Heating Coils  

E-Print Network [OSTI]

............................................................................................... 7 2.4 Summary of Literature Review .................................................................... 8 2.5 Significance of the Study ............................................................................. 9 2.6 Limitations... .................................................................. 25 Figure 8: Integrated Face/Bypass Damper Arrangement (Owen, 2005)..................... 26 Figure 9: Schematic of Specimen AHU and its Steam Supply, Alexandria, LA ........ 32 Figure 10: Preheat Temperature Plot for Steam Pressure...

Ali, Mir Muddassir

2012-02-14T23:59:59.000Z

191

Email To Friend Steam Electricity Generator  

E-Print Network [OSTI]

. keymanengravables.com Steam Turbine Generator Info, Pictures And Deals For Steam turbine generator ediscountshopping can make electricity directly." Logan's process uses a microbial fuel cell to convert organic material - that consume the sugars and other organic material and release electrons. These electrons travel to the anode

192

Circumferential cracking of steam generator tubes  

SciTech Connect (OSTI)

On April 28, 1995, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 95-03, {open_quote}Circumferential Cracking of Steam Generator Tubes.{close_quote} GL 95-03 was issued to obtain information needed to verify licensee compliance with existing regulatory requirements regarding the integrity of steam generator tubes in domestic pressurized-water reactors (PWRs). This report briefly describes the design and function of domestic steam generators and summarizes the staff`s assessment of the responses to GL 95-03. The report concludes with several observations related to steam generator operating experience. This report is intended to be representative of significant operating experience pertaining to circumferential cracking of steam generator tubes from April 1995 through December 1996. Operating experience prior to April 1995 is discussed throughout the report, as necessary, for completeness.

Karwoski, K.J.

1997-04-01T23:59:59.000Z

193

DOEEA-1178 Assessment 300 Area Steam Plant Replacement, Hanford...  

Broader source: Energy.gov (indexed) [DOE]

facilities would not be achieved. 5.3.4 Upgrade Central Steam System Impacts from upgrading the central steam system would include a reduction in the operational costs...

194

Recent Progress on Steam Hydrogasification of Carbonaceous Matter...  

Broader source: Energy.gov (indexed) [DOE]

Recent Progress on Steam Hydrogasification of Carbonaceous Matter to Clean Synthetic Diesel Fuel Recent Progress on Steam Hydrogasification of Carbonaceous Matter to Clean...

195

Improving Steam System Performance: A Sourcebook for Industry...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Improving Steam System Performance: A Sourcebook for Industry, Second Edition Improving Steam System Performance: A Sourcebook for Industry, Second Edition This sourcebook is...

196

Dow Chemical Company: Assessment Leads to Steam System Energy...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Dow Chemical Company: Assessment Leads to Steam System Energy Savings in a Petrochemical Plant Dow Chemical Company: Assessment Leads to Steam System Energy Savings in a...

197

Steam System Efficiency Optimized After J.R. Simplot Fertilizer...  

Broader source: Energy.gov (indexed) [DOE]

Steam System Efficiency Optimized After J.R. Simplot Fertilizer Plant Receives Energy Assessment Steam System Efficiency Optimized After J.R. Simplot Fertilizer Plant Receives...

198

Comparative Investigation of Benzene Steam Reforming over Spinel...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Investigation of Benzene Steam Reforming over Spinel Supported Rh and Ir Catalysts. Comparative Investigation of Benzene Steam Reforming over Spinel Supported Rh and Ir Catalysts....

199

Freeze drying method  

SciTech Connect (OSTI)

The present invention provides methods and apparatus for freeze drying in which a solution, which can be a radioactive salt dissolved within an acid, is frozen into a solid on vertical plates provided within a freeze drying chamber. The solid is sublimated into vapor and condensed in a cold condenser positioned above the freeze drying chamber and connected thereto by a conduit. The vertical positioning of the cold condenser relative to the freeze dryer helps to help prevent substances such as radioactive materials separated from the solution from contaminating the cold condenser. Additionally, the system can be charged with an inert gas to produce a down rush of gas into the freeze drying chamber to also help prevent such substances from contaminating the cold condenser.

Coppa, Nicholas V. (Malvern, PA); Stewart, Paul (Youngstown, NY); Renzi, Ernesto (Youngstown, NY)

1999-01-01T23:59:59.000Z

200

Freeze drying apparatus  

SciTech Connect (OSTI)

The present invention provides methods and apparatus for freeze drying in which a solution, which can be a radioactive salt dissolved within an acid, is frozen into a solid on vertical plates provided within a freeze drying chamber. The solid is sublimated into vapor and condensed in a cold condenser positioned above the freeze drying chamber and connected thereto by a conduit. The vertical positioning of the cold condenser relative to the freeze dryer helps to help prevent substances such as radioactive materials separated from the solution from contaminating the cold condenser. Additionally, the system can be charged with an inert gas to produce a down rush of gas into the freeze drying chamber to also help prevent such substances from contaminating the cold condenser.

Coppa, Nicholas V. (Malvern, PA); Stewart, Paul (Youngstown, NY); Renzi, Ernesto (Youngstown, NY)

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Dry Process Electrode Fabrication  

Broader source: Energy.gov (indexed) [DOE]

250m of free standing dry process cathode at thickness >200 m thickness. + Validate cost model by running pilot coating line at >25 mmin. + Deliver 24 cells in A123 SOA EV...

202

Dry Process Electrode Fabrication  

Broader source: Energy.gov (indexed) [DOE]

free standing dry process cathode that retains 50% capacity at 1C rate. + Validate cost model by running pilot coating line. + Deliver 24 cells in SOA EV cell format....

203

Dry Process Electrode Fabrication  

Broader source: Energy.gov (indexed) [DOE]

free standing dry process cathode that retains 50% capacity at 1C rate. + Validate cost model by running pilot coating line. + Deliver 24 cells in SOA EV cell format. 3...

204

High Temperature Steam Corrosion of Cladding for Nuclear Applications: Experimental  

SciTech Connect (OSTI)

Stability of cladding materials under off-normal conditions is an important issue for the safe operation of light water nuclear reactors. Metals, ceramics, and metal/ceramic composites are being investigated as substitutes for traditional zirconium-based cladding. To support down-selection of these advanced materials and designs, a test apparatus was constructed to study the onset and evolution of cladding oxidation, and deformation behavior of cladding materials, under loss-of-coolant accident scenarios. Preliminary oxidation tests were conducted in dry oxygen and in saturated steam/air environments at 1000OC. Tube samples of Zr-702, Zr-702 reinforced with 1 ply of a -SiC CMC overbraid, and sintered a-SiC were tested. Samples were induction heated by coupling to a molybdenum susceptor inside the tubes. The deformation behavior of He-pressurized tubes of Zr-702 and SiC CMC-reinforced Zr-702, heated to rupture, was also examined.

McHugh, Kevin M; Garnier, John E; Sergey Rashkeev; Michael V. Glazoff; George W. Griffith; Shannong M. Bragg-Sitton

2013-01-01T23:59:59.000Z

205

MEMORANDUM OWNER(S)  

Office of Legacy Management (LM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofof EnergyYou$ EGcG ENERGYELIkNATIONHEALXH:LTS- ,.__.-.I TO:

206

OWNER(S)  

Office of Legacy Management (LM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofof EnergyYou$0.C. 20545 OCT 28 1% - :NEW; c3 Alexander941@*2,l .

207

OWNER(S)  

Office of Legacy Management (LM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofof EnergyYou$0.C. 20545 OCT 28 1% - :NEW; c3 Alexander941@*2,l

208

OWNER(S)  

Office of Legacy Management (LM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofof EnergyYou$0.C. 20545 OCT 28 1% - :NEW; c3

209

OWNER(S) Past:  

Office of Legacy Management (LM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofof EnergyYou$0.C. 20545 OCT 28 1% - :NEW; c3--------------__

210

SUBJECT: OWNER(S)  

Office of Legacy Management (LM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarlyEnergyDepartment ofDepartment ofof EnergyYou$0.C. 20545 OCT 28 1%AU62SIhBCL:HEHORANDUH ;;&;

211

Steam turbine upgrades: A utility based approach  

SciTech Connect (OSTI)

In the increasingly competitive power generation markets utilities must strive towards lower electricity generation costs, whilst relying on an aging steam turbine fleet. By the year 2000 more than 25% of the global steam turbine capacity will be older than 30 years. The heat rate of such units is generally considerably higher than that of equivalent new plant, and such equipment can be further disadvantaged by increased maintenance costs and forced outage rates. Over the past decade steam turbine conversion, modification, and upgrade packages have become an increasingly important part of the European steam turbine market. Furthermore, many utilities now realize that enhanced cost-effectiveness can often be obtained by moving away from the original equipment manufacturer (OEM), and the upgrading of other manufacturers' plant is now routine within the steam turbine industry. By working closely with customers, GE has developed a comprehensive range of steam turbine upgrade packages, including advanced design steampaths which can increase the performance of existing turbine installations to levels comparable with new plant. Such packages are tailor-made to the requirements of each customer, to ensure that the most cost-effective engineering solution is identified. This paper presents an overview of GE's state-of-the-art steam turbine technology, and continues to describe typical economic models for turbine upgrades.

Wakeley, G.R.

1998-07-01T23:59:59.000Z

212

Steam reforming utilizing iron oxide catalyst  

SciTech Connect (OSTI)

High activity steam reforming iron oxide catalysts are described. Such catalysts can be unsupported utilizing at least 90% by weight iron oxide and various modifiers (Ai/sub 2/O/sub 3/, K/sub 2/O, CaO, SiO/sub 2/) or unmodified and supported on such things as alumina, CaO impregnated alumina, and lanthanum stabilized alumina. When used in steam reformers such as autothermal and tubular steam reformers, these catalysts demonstrate much improved resistance to carbon plugging.

Setzer, H. T.; Bett, J. A. S.

1985-06-11T23:59:59.000Z

213

Economic Analysis of "Steam-Shock" and "Pasteurization"  

E-Print Network [OSTI]

Economic Analysis of "Steam-Shock" and "Pasteurization" Processes for Oyster Shucking JOHN W. BROWN Introduction "Steam-shock" is an oyster shucking process that uses steam to relax the oyster's adductor muscle of the shucking process as in integral part of the operation of an existing oyster-shucking house. The term "steam

214

The Enbridge "Steam Saver" Program: Steam Boiler Plant Efficiency-Update to Year End 2005  

E-Print Network [OSTI]

industrial sectors are represented. The automotive, pulp-and -paper, petrochemical and steel industries are particularly large energy and steam users. Food and beverage processors are also heavy steam consumers. The Enbridge franchise service area... summary of the results of the boiler plant audit program. This data excludes other programs such as steam trap surveys and insulation surveys to be presented later in this paper. In summary, 13.7% of the total fuel can be saved if all identified...

Griffin, B.; Johnson, D.

2006-01-01T23:59:59.000Z

215

The revolutionary impact of the steam engine  

E-Print Network [OSTI]

Sitting with a model of Stephenson抯 Rocket, Simon Schaffer reflects on the steam revolution and how it changed the world in the nineteenth century in so many different ways....

Dugan, David

2004-08-18T23:59:59.000Z

216

How did the Rocket steam engine work?  

E-Print Network [OSTI]

Simon Schaffer talks to a museum curator at the York railway museum about the way in which steam engines worked and the imagination and technical ability of George Stephenson....

Dugan, David

2004-08-17T23:59:59.000Z

217

Steam Management- The 3M Approach  

E-Print Network [OSTI]

As one of the world's leading manufacturers of innovative products, 3M is continually working to improve energy efficiency in offices, research centers, and production facilities. Steam system optimization is one of the keys to this process...

Renz, R. L.

218

Optimizing Steam & Condensate System: A Case Study  

E-Print Network [OSTI]

Optimization of Steam & Condensate systems in any process plant results in substantial reduction of purchased energy cost. During periods of natural gas price hikes, this would benefit the plant in controlling their fuel budget significantly...

Venkatesan, V. V.; Norris, C.

2011-01-01T23:59:59.000Z

219

Steam System Optimization : A Case Study  

E-Print Network [OSTI]

The steam system optimization (generation, distribution, use and condensate return) offers a large opportunity for action to comply with the new levels of energy efficiency standards. Superior design and improved maintenance practices are the two...

Iordanova, N.; Venkatesan, V. V.; Calogero, M.

220

Smokeless Control of Flare Steam Flow Rate  

E-Print Network [OSTI]

measurement of mass flow rate of flare gas, in spite of the hostile environment. Its use for initiating control of flare steam flow rate and the addition of molecular weight compensation, using specific gravity (relative density) measurement to achieve...

Agar, J.; Balls, B. W.

1979-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Cogeneration: An Industrial Steam and Power Option  

E-Print Network [OSTI]

Industrial facilities of all sizes have the ability to reduce and better control both power and steam costs with a cogeneration system. Unlike the larger systems that sell almost all of the cogenerated power to a regulated electric utility...

Orlando, J. A.; Stewart, M. M.; Roberts, J. R.

222

Compressor & Steam Turbine Efficiency Improvements & Revamping Opportunities  

E-Print Network [OSTI]

in which they operate. This energy growth requires high efficiency improvements for machine design and operation to minimize life cycle cost. This paper will focus on the mechanical drive steam turbines which power the main process equipment in the heart...

Hata, S.; Horiba, J.; Sicker, M.

2011-01-01T23:59:59.000Z

223

Extraction Steam Controls at EPLA-W  

E-Print Network [OSTI]

ExxonMobil's Baton Rouge site encompasses a world-scale refinery, chemical plant and third party power station. Historically, inflexible and unreliable control systems on two high-pressure, extracting/condensing steam turbines prevented the site...

Brinker, J. L.

2004-01-01T23:59:59.000Z

224

Solar steam generation by heat localization  

E-Print Network [OSTI]

Currently, steam generation using solar energy is based on heating bulk liquid to high temperatures. This approach requires either costly high optical concentrations leading to heat loss by the hot bulk liquid and heated ...

Ghasemi, Hadi

225

Steam turbine upgrading: low-hanging fruit  

SciTech Connect (OSTI)

The thermodynamic performance of the steam turbine, more than any other plant component, determines overall plant efficiency. Upgrading steam path components and using computerized design tools and manufacturing techniques to minimise internal leaks are two ways to give tired steam turbines a new lease on life. The article presents three case studies that illustrate how to do that. These are at Unit 1 of Dairyland's J.P. Madgett Station in Alma, WI, a coal-fired subcritical steam plant; the four units at AmerenUE's 600 MW coal-fired Labadie plant west of St. Louis; and Unit 3 of KeyPlan Corp's Northport Power Station on Long Island. 8 figs.

Peltier, R.

2006-04-15T23:59:59.000Z

226

Consider Steam Turbine Drives for Rotating Equipment  

SciTech Connect (OSTI)

This revised ITP tip sheet on steam turbine drives for rotating equipment provides how-to advice for improving the system using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

227

Savings in Steam Systems (A Case Study)  

E-Print Network [OSTI]

Savings in Steam Systems (A Case Study) Rich DeBat Steam Systems Engineer Armstrong Service, Inc. Three Rivers, MI ABSTRACT Armstrong Service Inc. (ASI) conducted an engineered evaluation at an Ammonium Nitrate Manufacturing facility during... existing burner system after refractory repair and continue with normal operation of the existing boiler. Annstrong Service cannot guarantee any aspect of this option. Option 2. Armstrong Service, Inc. proposes to evaluate, select and install a...

DeBat, R.

228

World Class Boilers and Steam Distribution System  

E-Print Network [OSTI]

WORLD CLASS BOILERS AND STEAM DISTRIBUTION SYSTEM Vernon P. Portell, Ph.D. Manager Armstrong Service, Inc. ABSTRACT categorizing, measuring, and comparing subjects which are of interest to us is the way we identify the "World class" is a... of information can also be obtained through an independent firm that provides third-party assessment of steam systems. One of these third parties, Armstrong Energy Certification, Inc., has used data gleaned from decades of industrial experience...

Portell, V. P.

229

Cheng Cycle Brings Flexibility to Steam Plant  

E-Print Network [OSTI]

. Based upon an estimated steam load between 5,000 and 50,000 Ibjhr and an electrical load of approximately 1500 KW, the Engineering Department examined several energy optimization systems for this site. It was determined that a modified gas turbine... within the borders allows exact tracking of desired electrical and thermal outputs. The Allison engine used in the Cheng Cycle system was selected for its proved performance and its ample surge margin which permits stable steam injection...

Keller, D. C.; Bynum, D.; Kosla, L.

230

Control system for fluid heated steam generator  

DOE Patents [OSTI]

A control system for controlling the location of the nucleate-boiling region in a fluid heated steam generator comprises means for measuring the temperature gradient (change in temperature per unit length) of the heating fluid along the steam generator; means for determining a control variable in accordance with a predetermined function of temperature gradients and for generating a control signal in response thereto; and means for adjusting the feedwater flow rate in accordance with the control signal.

Boland, J.F.; Koenig, J.F.

1984-05-29T23:59:59.000Z

231

Oxidation of advanced steam turbine alloys  

SciTech Connect (OSTI)

Advanced or ultra supercritical (USC) steam power plants offer the promise of higher efficiencies and lower emissions. Current goals of the U.S. Department of Energy抯 Advanced Power Systems Initiatives include coal generation at 60% efficiency, which would require steam temperatures of up to 760癈. This research examines the steamside oxidation of advanced alloys for use in USC systems, with emphasis placed on alloys for high- and intermediate-pressure turbine sections.

Holcomb, G.R.; Covino, B.S., Jr.; Bullard, S.J.; Ziomek-Moroz, M.

2006-03-01T23:59:59.000Z

232

ExxonMobile Beaumont Chemical Plant Steam Integration Project  

E-Print Network [OSTI]

? Conventional boilers ? Gas turbine generators/ heat recovery steam generators ? Waste heat recovery boilers ? Steam is distributed and consumed at multiple locations and at various levels ? Evolution across the site can lead to isolated steam imbalances 4... the chemical plant boundaries ? The Refinery had a need for this valuable energy resource. ? A project was conceived to install piping and control systems to export the excess medium pressure steam to the adjacent Refinery where the steam could be more...

Long, T.

233

Apparatus and methods of reheating gas turbine cooling steam and high pressure steam turbine exhaust in a combined cycle power generating system  

DOE Patents [OSTI]

In a combined cycle system having a multi-pressure heat recovery steam generator, a gas turbine and steam turbine, steam for cooling gas turbine components is supplied from the intermediate pressure section of the heat recovery steam generator supplemented by a portion of the steam exhausting from the HP section of the steam turbine, steam from the gas turbine cooling cycle and the exhaust from the HP section of the steam turbine are combined for flow through a reheat section of the HRSG. The reheated steam is supplied to the IP section inlet of the steam turbine. Thus, where gas turbine cooling steam temperature is lower than optimum, a net improvement in performance is achieved by flowing the cooling steam exhausting from the gas turbine and the exhaust steam from the high pressure section of the steam turbine in series through the reheater of the HRSG for applying steam at optimum temperature to the IP section of the steam turbine.

Tomlinson, Leroy Omar (Niskayuna, NY); Smith, Raub Warfield (Ballston Lake, NY)

2002-01-01T23:59:59.000Z

234

DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference  

Broader source: Energy.gov [DOE]

More than 150 energy sector leaders梚ncluding nearly 100 asset owners and operators梘athered at the 2009 EnergySec Annual Summit in Seattle, WA, on Sept. 23-24, where researchers from the...

235

An Internet survey of private pond owners and managers in Texas  

E-Print Network [OSTI]

pond owners got the information they used to deal with pond management problems. A secondary emphasis of the project was to examine the potential presented by the Internet for use in this type of information gathering and distribution for Texas...

Schonrock, April Elizabeth

2005-11-01T23:59:59.000Z

236

Texas State Offshore Dry Natural Gas Expected Future Production (Billion  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecemberSteamYear JanSeparation, Proved1 4.70 1967-2010Cubic Feet) Dry Natural

237

Hoe Creek No. 3 - First long-term underground coal gasification experiment with oxygen-steam injection  

SciTech Connect (OSTI)

The paper describes the first long-term underground coal gasification experiment with oxygen-steam injection. In the Hoe Creek No. 3 underground experiment, linkage paths were established between the injection and production wells by drilling a horizontal borehole between them near the bottom of the coal seam. The drilled linkage hole was enlarged by reverse burning, and then the forward gasification process was started - first with air injection for one week, then with oxygen-steam injection for the remainder of the experiment. During the oxygen-steam injection period, about 3900 tons of coal were gasified in 47 days, at an average rate of 83 tons per day. The heating value of the dry product gas averaged 218 Btu/scf, suitable for input to a processing plant for upgrading to pipeline quality, which is about 900 Btu/scf.

Not Available

1980-05-01T23:59:59.000Z

238

GENERATION, TRANSPORT AND DEPOSITION OF TUNGSTEN-OXIDE AEROSOLS AT 1000 C IN FLOWING AIR-STEAM MIXTURES.  

SciTech Connect (OSTI)

Experiments were conducted to measure the rates of oxidation and vaporization of pure tungsten rods in flowing air, steam and air-steam mixtures in laminar flow. Also measured were the downstream transport of tungsten-oxide condensation aerosols and their region of deposition, including plateout in the superheated flow tube, rainout in the condenser and ambient discharge which was collected on an array of sub-micron aerosol filters. The nominal conditions of the tests, with the exception of the first two tests, were tungsten temperatures of 1000 C, gas mixture temperatures of 200 C and wall temperatures of 150 C to 200 C. It was observed that the tungsten oxidation rates were greatest in all air and least in all steam, generally decreasing non-linearly with increasing steam mole fraction. The tungsten oxidation rates in all air were more than five times greater than the tungsten oxidation rates in all steam. The tungsten vaporization rate was zero in all air and increased with increasing steam mole fraction. The vaporization rate became maximum at a steam mole fraction of 0.85 and decreased thereafter as the steam mole fraction was increased to unity. The tungsten-oxide was transported downstream as condensation aerosols, initially flowing upwards from the tungsten rod through an 18-inch long, one-inch diameter quartz tube, around a 3.5-inch radius, 90{sup o} bend and laterally through a 24-inch horizontal run. The entire length of the quartz glass flow path was heated by electrical resistance clamshell heaters whose temperatures were individually controlled and measured. The tungsten-oxide plateout in the quartz tube was collected, nearly all of which was deposited at the end of the heated zone near the entrance to the condenser which was cold. The tungsten-oxide which rained out in the condenser as the steam condensed was collected with the condensate and weighed after being dried. The aerosol smoke which escaped the condenser was collected on the sub-micron filter assemblies. There was no aerosol generation for the case of all air, so the plateout, condensate and smoke were all zero. For the case of all steam, there was very little plateout in the superheated regions (several percent) and the rest of the aerosol was collected in the condensate from the condenser. There was no smoke discharge into the filters. For the experiments with intermediate air-steam fractions, there was some aerosol plateout, considerable aerosol in the condensate and aerosol smoke discharged from the condenser with the escaping air.

GREENE,G.A.; FINFROCK,C.C.

2001-10-01T23:59:59.000Z

239

A comparison of noxious facilities` impacts for home owners versus renters  

SciTech Connect (OSTI)

The siting of noxious facilities, such as hazardous waste facilities, is often vigorously opposed by local residents, and thus it is now common for local residents to be compensated for the presence of the facility. One technique that has been employed to implicitly value noxious facilities is the intercity hedonic approach, which examines the wage and land rent premia between cities that result from the presence of the facility. However, most of the focus has been on the behavior of home owners as opposed to renters. Since these two groups of residents vary on numerous dimensions such as marital status, age, sex, and personal mobility, it would not be surprising to find different marginal valuations of local site characteristics. The authors use 1980 Census data to derive separate estimates for owners and renters of the implicit value placed on eight different types of noxious facilities. They find that renters and owners differ in their response to noxious facilities, although the differences are not systematic. Furthermore, the differences between owners and renters are not primarily due to differential mobility or socio-demographic factors. Controlling those factors decreases the differences between renters` and owners` implicit valuations of noxious facilities by less than 10%. Unmeasured differences between the two groups, such as tastes, risk aversion, or commitment to the community, must account for the remaining difference in valuations. These findings suggest that policymakers should separately consider the responses of owners and renters when estimating noxious facility impacts.

Clark, D.E. [Marquette Univ., Milwaukee, WI (United States). Dept. of Economics]|[Argonne National Lab., IL (United States); Nieves, L.A. [Argonne National Lab., IL (United States)

1995-01-01T23:59:59.000Z

240

Boiler Efficiency vs. Steam Quality- The Challenge of Creating Quality Steam Using Existing Boiler Efficiencies  

E-Print Network [OSTI]

A boiler works under pressure and it is not possible to see what is happening inside of it. The terms "wet steam" and "carry over" are every day idioms in the steam industry, yet very few people have ever seen these phenomena and the actual water...

Hahn, G.

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Solving chemical and mechanical problems of PWR steam generators  

SciTech Connect (OSTI)

Steam generators in power plants, based on pressurized water reactors (PWRs), transfer heat from a primary coolant system (pressurized water) to a secondary coolant system. Primary coolant water is heated in the core and passes through the steam generator that transfers heat to the secondary coolant water to make steam. The steam then drives a turbine that turns an electric generator. Steam is condensed and returned to the steam generator as feedwater. Two types of PWR steam generators are in use: recirculating steam generators (RSGs) and once-through steam generators (OTSGs). Since most of the units are vertical, only vertical units are discussed in this article. Some vertical units have operated with a minimum of problems, while others have experienced a variety of corrosion and mechanically-induced problems that have caused unscheduled outages and expensive repairs.

Green, S.J.

1987-07-01T23:59:59.000Z

242

Visbreaking-enhanced thermal recovery method utilizing high temperature steam  

SciTech Connect (OSTI)

The displacement efficiency of a steam drive process is improved and steam override reduced by rapidly injecting a predetermined amount of high temperature steam via an injection well into the formation to visbreak a portion of the oil in the formation prior to a steam drive wherein steam is injected into the formation via the injection well to displace oil to a spaced-apart production well through which oil is recovered. The visbroken oil provides a more favorable transition of mobility ratio between the phases in the formation thereby reducing viscous fingering and increasing the displacement efficiency of the steam drive. In addition, after a predetermined amount of high temperature steam has been injected into the formation, the formation may be allowed to undergo a soak period prior to the steam drive. The high temperature steam injection and soaking steps may be sequentially repeated for a plurality of cycles.

Shu, W.R.

1984-06-26T23:59:59.000Z

243

Effects of aging and service wear on main steam isolation valves and valve operators  

SciTech Connect (OSTI)

In recent years main steam isolation valve (MSIV operating problems have resulted in significant operational transients (e.g., spurious reactor trips, steam generator dry out, excessive valve seat leakage), increased cost, and decreased plant availability. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data available through the Institute of Nuclear Power Operation`s Nuclear Plant Reliability Data System has been conducted for several types of MSIVs and valve operators for both boiling-water reactors and pressurized-water reactors. The focus of this review is on MSIV failures modes, actuator failure modes, consequences of failure on plant operations, method of failure detection, and major stressors affecting both valves and valve operators.

Clark, R.L. [Oak Ridge National Lab., TN (United States)

1996-03-01T23:59:59.000Z

244

A Better Steam Engine: Designing a Distributed Concentrating Solar Combined Heat and Power System  

E-Print Network [OSTI]

A Better Steam Engine: Designing a Distributed Concentrating2011 Abstract A Better Steam Engine: Designing a Distributedprovided for a steam Rankine cycle heat engine achieving 50%

Norwood, Zachary Mills

2011-01-01T23:59:59.000Z

245

Development of Steam Turbine Inlet Control Valve for Supercritical Pressure at Siemens Industrial Turbomachinery AB.  

E-Print Network [OSTI]

?? The development in the steam turbine business is heading for applications with much higher steam parameters since this enables a raised efficiency. Steam parameters (more)

Sors, Felix

2010-01-01T23:59:59.000Z

246

Energy Savings with Computerized Steam Trap Maintenance Program  

E-Print Network [OSTI]

by Armstrong International, Inc. Five other manufacturers each have about a 5% share of the tmp population, and about 5 more account for the remaining steam traps. 6,430 STEAM TRAPS COLl3Il~) FIGURE 3 - Steam trap population by application. 8,430 STEAM... standardized using the inverted bucket steam trap made by Armstrong International, Inc. "or equal", with approval, wherever applicable and sensible. I believe the inverted bucket steam trap is the best one for this. The selection of a good manufacturer...

Klidzejs, A. M.

247

Low VOC drying of lumber and wood panel products. Progress report No. 8  

SciTech Connect (OSTI)

This study was initiated by an Institute of Paper Science and Technology finding that heating softwood in a low-headspace environment removed much of the VOCs without removing the water. This offered the possibility of removing VOCs from wet wood, capturing them as a product, and then drying the VOC-depleted wood conventionally with little or no VOC controls. Two means of low-headspace heating were explored: steam and radiofrequency (RF). It was found in the previous year, that while both steam and RF were able to drive out VOCs, steam was impracticably slow for lumber. Hence the effect of RF or microwave on wood was the principal focus of the work reported here. Finally, in order to understand the mechanism of VOC release, the transport of the VOCs in wood was studied, together with the seasonal effects that influence VOC concentration in trees.

Su, W.; Yan, H.; Hooda, U.; Wild, M.P.; Banerjee, S. [Inst. of Paper Science and Technology, Atlanta, GA (United States)] [Inst. of Paper Science and Technology, Atlanta, GA (United States); Shmulsky, R.; Thompson, A.; Ingram, L.; Conners, T. [Mississippi State Univ., MS (United States)] [Mississippi State Univ., MS (United States)

1998-07-01T23:59:59.000Z

248

An evaluation of the benefits of combined steam and fireflooding as a recovery process for heavy oils  

SciTech Connect (OSTI)

Lack of oil mobility is a major problem with in situ combustion field projects, since the combustion front displaces oil into an essentially unheated reservoir. One way of ensuring oil mobility is to utilize steam injection during the early life of the process, and then switch to combustion when heated communication paths have been developed. The in situ combustion characteristics of cores from the Primrose reservoir of Northeastern Alberta were investigated in a comprehensive series of 22 combustion tube tests. The program was carried out in order to evaluate the effectiveness of fireflooding in both cores that had been preheated to the extent that the oil was mobile and in those which were steam-flooded prior to dry combustion. Both normal- and 95% oxygen-enriched air were evaluated. Wet combustion tests were performed utilizing both liquid water and steam injection. The effects of parameters such as pressure, oxygen enrichment and injection flux on the combustion characteristics were examined. This paper will discuss the results of this study, which show that steam co-injection is more effective at lowering the oxygen requirement than was combustion following steam. Additionally, the cores which were preheated exhibited similar oxygen requirements to those which were presteamed to a near-residual saturation.

Moore, R.G.; Laureshen, C.J.; Belgrave, J.D.M.; Ursenbach, M.G. [Univ. of Calgary, Alberta (Canada); Jha, K.N. [Dept. of Natural Resources Canada, Ottawa (Canada)

1995-02-01T23:59:59.000Z

249

Ultra supercritical turbines--steam oxidation  

SciTech Connect (OSTI)

Ultra supercritical (USC) power plants offer the promise of higher efficiencies and lower emissions, which are goals of the U.S. Department of Energy?s Advanced Power Systems Initiatives. Most current coal power plants in the U.S. operate at a maximum steam temperature of 538?C. However, new supercritical plants worldwide are being brought into service with steam temperatures of up to 620?C. Current Advanced Power Systems goals include coal generation at 60% efficiency, which would require steam temperatures of up to 760?C. This research examines the steamside oxidation of advanced alloys for use in USC systems, with emphasis placed on alloys for high- and intermediate-pressure turbine sections. Initial results of this research are presented.

Holcomb, Gordon R.; Covino, Bernard S., Jr.; Bullard, Sophie J.; Cramer, Stephen D.; Ziomek-Moroz, Margaret; Alman, David E.

2004-01-01T23:59:59.000Z

250

Integrated vacuum absorption steam cycle gas separation  

DOE Patents [OSTI]

Methods and systems for separating a targeted gas from a gas stream emitted from a power plant. The gas stream is brought into contact with an absorption solution to preferentially absorb the targeted gas to be separated from the gas stream so that an absorbed gas is present within the absorption solution. This provides a gas-rich solution, which is introduced into a stripper. Low pressure exhaust steam from a low pressure steam turbine of the power plant is injected into the stripper with the gas-rich solution. The absorbed gas from the gas-rich solution is stripped in the stripper using the injected low pressure steam to provide a gas stream containing the targeted gas. The stripper is at or near vacuum. Water vapor in a gas stream from the stripper is condensed in a condenser operating at a pressure lower than the stripper to concentrate the targeted gas. Condensed water is separated from the concentrated targeted gas.

Chen, Shiaguo (Champaign, IL); Lu, Yonggi (Urbana, IL); Rostam-Abadi, Massoud (Champaign, IL)

2011-11-22T23:59:59.000Z

251

Apparatus for removing micronized coal from steam  

SciTech Connect (OSTI)

Micronized coal is removed from coal-bearing steam by spraying stabilized petroleum oil into the steam and directing the resultant stream at a separation surface on which a coal-oil slurry is deposited and collected. Apparatus includes conduits which direct the resultant stream downward into a housing and normal to a surface on which the slurry is deposited by impact forces. In additional apparatus disclosed, the resultant stream is directed from a horizontal conduit circumferentially along the interior wall of a horizontally disposed cylindrical chamber at the top of the chamber and the coal-oil slurry deposited on the wall by centrifugal force is collected in a trough situated below a longitudinal slot at the bottom of the chamber. In both types of apparatus, after separation of the slurry the velocity of the steam is reduced to settle out remaining oil droplets and is then discharged to the atmosphere.

Vlnaty, J.

1981-12-15T23:59:59.000Z

252

Improved plant performance through evaporative steam condensing  

SciTech Connect (OSTI)

Combining an open cooling tower and a steam condenser into one common unit is a proven technology with many advantages in power generation application, including reduced first cost of equipment, reduced parasitic energy consumption, simplified design, reduced maintenance, and simplified water treatment, Performance of the steam turbine benefits from the direct approach to wet bulb temperature, and operating flexibility and reliability improve compared to a system with a cooling tower and surface condenser. System comparisons and case histories will be presented to substantiate improved systems economies.

Hutton, D.

1998-07-01T23:59:59.000Z

253

Steam Trap Maintenance as a Profit Center  

E-Print Network [OSTI]

the Eighteenth Industrial Energy Technology Conference, Houston, TX, April 17-18, 1996 EXCUSES Everybody thinks his or her steam trap maintenance is good. Surveysl have shown the following are the most popular excuses encountered when managers are confronted... for steam traps. 192 ESL-IE-96-04-28 Proceedings from the Eighteenth Industrial Energy Technology Conference, Houston, TX, April 17-18, 1996 5. Set up a trap maintenance program C. Prepare and present a report to that will: management on the results...

Bouchillon, J. L.

254

Energy & Environmental Benefits from Steam & Electricity Cogeneration  

E-Print Network [OSTI]

steam from two on-site powerhouses (one coal-fired and one natural gas-fired) and from gas-fired and waste heat boilers in its four hydrocarbon cracking plants. The challenge was to find a way to reduce costs and improve reliability of procuring and... the electricity required by TEX and sells excess power to wholesale customers in the region. It provides a large portion of TEX steam requirements, with sufficient reliability such that TEX decommissioned its coal-fired powerhouse and reduced operations...

Ratheal, R.

2004-01-01T23:59:59.000Z

255

23rd steam-station cost survey  

SciTech Connect (OSTI)

The results of the 23rd Steam Station Cost Survey covering the year 1982 are summarized. The major categories of the survey are as follows: general data; output data, 1982; fuel consumption, 1982; operation 1982 (mills/net kWh); investment ($/net kWh); energy cost, 1982 (mills/net kWh); and station performance, 1982. Thirty-one fossil-fuel steam plants and four nuclear stations were included in the survey. Fuel and operating cost increases are felt to be responsible for the moderate rise in total busbar-enery costs. 11 figures, 1 table.

Friedlander, G.D.; Going, M.C.

1983-11-01T23:59:59.000Z

256

E-Print Network 3.0 - advanced steam generators Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

THEORY AND IN PRACTICE. BY R... OF A HISTORY OF THE STEAM-EN- GINE, A MANUAL OF THE STEAM-ENGINE, A MANUAL OF STEAM-BOILERS, ETC., ETC., ETC... treatise on Steam-Boiler Explosions...

257

Energy Conservation Thru Steam Trap Surveys and Preventive Maintenance Programs  

E-Print Network [OSTI]

ENERGY CONSERVATION THRU STEAM TRAP SURVEYS AND PREVENTIVE MAINTENANCE PROGRAMS Terry Boynton, Armstrong, Three Rivers, Mich. Bob Dewhirst, Armstrong, New Braunfels, Texas. This paper will deal with steam trap surveys and preventive maintenance...

Boynton, T.; Dewhirst, B.

1980-01-01T23:59:59.000Z

258

Pafnuty Chebyshev, Steam Engines, and Polynomials by John Albert  

E-Print Network [OSTI]

Pafnuty Chebyshev, Steam Engines, and Polynomials by John Albert OU Mathfest, January 2009 1 professorship at age 61, but continued to work on mathematics right up to his death at age 73. 2. Steam Engines

Albert, John

259

Following Where the Steam Goes: Industry's Business Opportunity  

E-Print Network [OSTI]

Many associated benefits accrue from plant projects which comprehensively address steam systems. The DOE-Alliance to Save Energy Steam Challenge program was initiated shortly after last year's IETC on April 30, 1998 to promote awareness...

Jaber, D.; Jones, T.

260

Optimization of Steam Network in Tehran Oil Refinery  

E-Print Network [OSTI]

case study and its steam network is analyzed. At the first step, using STAR software, the steam network is simulated and then optimized, which determines the optimum conditions. In this regard, energy saving potential was identified and total operating...

Khodaie, H.; Nasr, M. R. J.

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

The Analysis and Development of Large Industrial Steam Systems  

E-Print Network [OSTI]

Chemicals, petroleum, pulp and paper, and many other industries depend heavily on extensive complex steam systems for thermal and mechanical energy delivery. Steam's versatility and desirable characteristics as both a heat transfer medium and a...

Waterland, A. F.

1980-01-01T23:59:59.000Z

262

Use a Vent Condenser to Recover Flash Steam Energy (Revised)  

SciTech Connect (OSTI)

This revised ITP tip sheet on vent condenser to recover flash steam energy provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-05-01T23:59:59.000Z

263

Case Study- Steam System Improvements at Dupont Automotive Marshall Laboratory  

E-Print Network [OSTI]

and implement small scale cogeneration. These recommendations included reducing the medium pressure steam distribution to low pressure, eliminating the medium pressure to low pressure reducing stations, installing a back pressure steam turbine generator...

Larkin, A.

264

Finding Benefits by Modeling and Optimizing Steam and Power Systems  

E-Print Network [OSTI]

A site-wide steam modeling and optimization program (Visual MESA) was implemented at the INEOS Chocolate Bayou site. This program optimizes steam production, compressor turbine extraction, pump operation (turbine/motor) operation, as well...

Jones, B.; Nelson, D.

2007-01-01T23:59:59.000Z

265

Steam Tracing...New Technologies for the 21st Century  

E-Print Network [OSTI]

For decades, steam tracing has been an accepted practice in the heating of piping, vessels, and equipment. This paper presents recent product innovations such as "burn-safe" and "energy efficient" steam tracing products. For the many applications...

Pitzer, R. K.; Barth, R. E.; Bonorden, C.

266

Method of drying articles  

DOE Patents [OSTI]

A method of drying a green particulate article includes the steps of: a. Providing a green article which includes a particulate material and a pore phase material, the pore phase material including a solvent; and b. contacting the green article with a liquid desiccant for a period of time sufficient to remove at least a portion of the solvent from the green article, the pore phase material acting as a semipermeable barrier to allow the solvent to be sorbed into the liquid desiccant, the pore phase material substantially preventing the liquid desiccant from entering the pores.

Janney, Mark A. (Knoxville, TN); Kiggans, Jr., James O. (Oak Ridge, TN)

1999-01-01T23:59:59.000Z

267

Method of drying articles  

DOE Patents [OSTI]

A method of drying a green particulate article includes the steps of: (a) Providing a green article which includes a particulate material and a pore phase material, the pore phase material including a solvent; and (b) contacting the green article with a liquid desiccant for a period of time sufficient to remove at least a portion of the solvent from the green article, the pore phase material acting as a semipermeable barrier to allow the solvent to be sorbed into the liquid desiccant, the pore phase material substantially preventing the liquid desiccant from entering the pores. 3 figs.

Janney, M.A.; Kiggans, J.O. Jr.

1999-03-23T23:59:59.000Z

268

Dry reforming of hydrocarbon feedstocks  

SciTech Connect (OSTI)

Developments in catalyst technology for the dry reforming of hydrocarbon feedstocks are reviewed for methane, higher hydrocarbons and alcohols. Thermodynamics, mechanisms and the kinetics of dry reforming are also reviewed. The literature on Ni catalysts, bi-metallic Ni catalysts and the role of promoters on Ni catalysts is critically evaluated. The use of noble and transitional metal catalysts for dry reforming is discussed. The application of solid oxide and metal carbide catalysts to dry reforming is also evaluated. Finally, various mechanisms for catalyst deactivation are assessed. This review also examines the various process related issues associated with dry reforming such as its application and heat optimization. Novel approaches such as supercritical dry reforming and microwave assisted dry reforming are briefly expanded upon.

Shah, Yatish T. [Norfolk State University; Gardner, Todd H. [U.S. DOE

2014-01-01T23:59:59.000Z

269

Best Management Practice #8: Boiler and Steam Systems  

Broader source: Energy.gov [DOE]

Boilers and steam generators are commonly used in large heating systems, institutional kitchens, or in facilities where large amounts of process steam are used. This equipment consumes varying amounts of water depending on system size, the amount of steam used, and the amount of condensate returned.

270

Project Recap Humanitarian Engineering Biodiesel Boiler System for Steam Generator  

E-Print Network [OSTI]

Project Recap Humanitarian Engineering 颅 Biodiesel Boiler System for Steam Generator Currently 70 biodiesel boiler system to drive a steam engine generator. This system is to provide electricity the customer needs, a boiler fueled by biodiesel and outputting to a steam engine was decided upon. The system

Demirel, Melik C.

271

Experience, Engagement and Social Interaction at a Steam Locomotive  

E-Print Network [OSTI]

of two interactive stations (figure 2) where visitors can add coal and water to the steam engine at station 1 and regulate the steam pressure in the engine at station 2, as well as a number of visualExperience, Engagement and Social Interaction at a Steam Locomotive Multimodal Interactive Museum

Hornecker, Eva

272

Steam Traps-The Oft Forgotten Energy Conservation Treasure  

E-Print Network [OSTI]

In these days of high technology, the steam trap is often treated as a commodity item, forgotten by many and respected by a relative few. Yet, in many facilities, widespread undetected failure of steam traps has wasted 5-15% of a plant's total steam...

Pychewicz, F. S.

273

Industrial Steam Power Cycles Final End-Use Classification  

E-Print Network [OSTI]

Final end uses of steam include two major classifications: those uses that condense the steam against heat transfer surfaces to provide heat to an item of process or service equipment; and those that require a mass flow of steam for stripping...

Waterland, A. F.

1983-01-01T23:59:59.000Z

274

Using HYTECH to Synthesize Control Parameters for a Steam Boiler ?;??  

E-Print Network [OSTI]

Using HYTECH to Synthesize Control Parameters for a Steam Boiler ?;?? Thomas A. Henzinger 1 Howard model a steam颅boiler control system using hybrid au颅 tomata. We provide two abstracted linear models constraints that guarantee the safety of the boiler. 1 Introduction A description of an industrial steam

Henzinger, Thomas A.

275

Steam boiler control speci cation problem: A TLA solution  

E-Print Network [OSTI]

Steam boiler control speci cation problem: A TLA solution Frank Le ke and Stephan Merz Institut fur of the state of the steam boiler, detect failures, and model message transmission. We give a more detailed between the physi- cal state of the steam boiler and the model maintained by the controller and discuss

276

COMPUTATION OF TWO-PHASE FLOW IN STEAM GENERATOR  

E-Print Network [OSTI]

COMPUTATION OF TWO-PHASE FLOW IN STEAM GENERATOR USING DOMAIN DECOMPOSITION AND LOCAL ZOOM METHODS Abstract We present ow simulations in the Steam Generator of a pressurized water nuclear reactor using coherence between the zoom and the full domain. Key words: Steam Generator, Zoom, Domain Decomposition

Paris-Sud XI, Universit茅 de

277

EXPERIMENTAL DETERMINATION OF STEAM WATER RELATIVE PERMEABILITY RELATIONS  

E-Print Network [OSTI]

EXPERIMENTAL DETERMINATION OF STEAM WATER RELATIVE PERMEABILITY RELATIONS A REPORT SUBMITTED;Abstract A set of relative permeability relations for simultaneous ow of steam and water in porous media with saturation and pressure measurements. These relations show that the relative permeability for steam phase

Stanford University

278

ORNL/TM-2001/263 Steam System Survey Guide  

E-Print Network [OSTI]

ORNL/TM-2001/263 Steam System Survey Guide Greg Harrell, Ph.D., P.E. #12;DOCUMENT AVAILABILITY Government or any agency thereof. #12;ORNL/TM-2001/263 STEAM SYSTEM SURVEY GUIDE Greg Harrell, Ph.D., P for the U.S. Department of Energy BestPractices Steam Program Prepared by OAK RIDGE NATIONAL LABORATORY Oak

Oak Ridge National Laboratory

279

EXPERIMENTAL MEASUREMENT OF STEAM-WATER RELATIVE PERMEABILITY  

E-Print Network [OSTI]

EXPERIMENTAL MEASUREMENT OF STEAM-WATER RELATIVE PERMEABILITY A REPORT SUBMITTED TO THE DEPARTMENT calculations. X-ray computer tomography (CT) aided by measuring in-situ steam saturation more directly. The measured steam-water relative permeability curves assume a shape similar to those obtained by Corey (1954

Stanford University

280

CHEM333: Experiment 4: Steam Distillation of Essential Oils;  

E-Print Network [OSTI]

CHEM颅333: Experiment 4: Steam Distillation of Essential Oils; Experiments A, C, D and below. Reading: For this experiment read Chapter 10. This week you will get to use steam distillation to isolate may wait until you come to lab to find out which spice you get. Steam distillation is not a common

Taber, Douglass

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Supported metal catalysts for alcohol/sugar alcohol steam reforming  

SciTech Connect (OSTI)

Despite extensive studies on hydrogen production via steam reforming of alcohols and sugar alcohols, catalysts typically suffer a variety of issues from poor hydrogen selectivity to rapid deactivation. Here, we summarize recent advances in fundamental understanding of functionality and structure of catalysts for alcohol/sugar alcohol steam reforming, and provide perspectives on further development required to design highly efficient steam reforming catalysts.

Davidson, Stephen; Zhang, He; Sun, Junming; Wang, Yong

2014-08-21T23:59:59.000Z

282

RELIABILITY OF SAMPLING INSPECTION SCHEMES APPLIED TO REPLACEMENT STEAM GENERATORS  

E-Print Network [OSTI]

RELIABILITY OF SAMPLING INSPECTION SCHEMES APPLIED TO REPLACEMENT STEAM GENERATORS Guy Roussel the size of the random sample of tubes to be inspected in replacement steam generators is revisited in this paper. A procedure to estimate the maximum number of defective tubes left in the steam generator after

Cizelj, Leon

283

An Object-Oriented Algebraic Steam-Boiler Control Specification  

E-Print Network [OSTI]

An Object-Oriented Algebraic Steam-Boiler Control Specification.In this paper an object-oriented algebraic solution of the steam-boiler specification problem is presented computations cannot happen. 1 Introduction The steam-boiler control specification problem has been

?lveczky, Peter Csaba

284

High Temperature Electrolysis of Steam and Carbon Dioxide  

E-Print Network [OSTI]

High Temperature Electrolysis of Steam and Carbon Dioxide S酶ren H酶jgaard Jensen+,#, Jens V. T. H酶gh + O2 #12;Electrolysis of steam at high temperature Interesting because 路 Improved thermodynamic of electrolysis of steam Picture taken from E. Erdle, J. Gross, V. Meyringer, "Solar thermal central receiver

285

Rapid Recolonisation of Agricultural Soil by Microarthropods After Steam Disinfestation  

E-Print Network [OSTI]

Rapid Recolonisation of Agricultural Soil by Microarthropods After Steam Disinfestation Stefano Fenoglio Paolo Gay Giorgio Malacarne Marco Cucco ABSTRACT. Steam disinfestation of soil is attracting. In this study, we assessed the effect of steam applica- tion on the microarthropod community, a fundamental

Cucco, Marco

286

An Object-Oriented Algebraic Steam-Boiler Control Specification  

E-Print Network [OSTI]

An Object-Oriented Algebraic Steam-Boiler Control Specification Peter Csaba ()lveczky, Poland Abstract. In this paper an object-oriented algebraic solution of the steam-boiler specification Introduction The steam-boiler control specification problem has been proposed as a challenge for different

?lveczky, Peter Csaba

287

Using HYTECH to Synthesize Control Parameters for a Steam Boiler? ??  

E-Print Network [OSTI]

Using HYTECH to Synthesize Control Parameters for a Steam Boiler? ?? Thomas A. Henzinger1 Howard model a steam-boiler control system using hybrid au- tomata. We provide two abstracted linear models that guarantee the safety of the boiler. 1 Introduction A description of an industrial steam boiler has been

Henzinger, Thomas A.

288

Numerical Simulation of a Natural Circulation Steam Generator  

E-Print Network [OSTI]

Numerical Simulation of a Natural Circulation Steam Generator W. Linzer \\Lambda , K. Ponweiser circulation steam generator. We focus on a model with a simple geometry consisting of two vertical pipes properties of water and steam. We present a numerical algorithm based on an explicit upwind discretization

Weinm眉ller, Ewa B.

289

Steam boiler control specification problem: A TLA solution  

E-Print Network [OSTI]

Steam boiler control specification problem: A TLA solution Frank Le?ke and Stephan Merz Institut f of the state of the steam boiler, detect failures, and model message transmission. We give a more detailed between the physi颅 cal state of the steam boiler and the model maintained by the controller and discuss

Merz, Stephan

290

Replace Pressure-Reducing Valves with Backpressure Turbogenerators (International Fact Sheet), Energy Tips-Steam, Steam Tip Sheet #20c  

SciTech Connect (OSTI)

This English/Chinese ITP steam tip sheet on replacing pressure-reducing valves provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2010-10-01T23:59:59.000Z

291

Steam Challenge: Developing A New DOE Program to Help Industry be Steam Smart  

E-Print Network [OSTI]

Last year, the Alliance to Save Energy, the Department of Energy's Office of Industrial Technologies, and a cadre of private companies and associations formed an innovative "Steam Partnership" with the goal of developing a new, DOE technical...

Jones, T.; Hart, F.

292

Improved Steam Assisted Gravity Drainage (SAGD) Performance with Solvent as Steam Additive  

E-Print Network [OSTI]

Steam Assisted Gravity Drainage (SAGD) is used widely as a thermal recovery technique in Canada to produce a very viscous bitumen formation. The main research objectives of this simulation and experimental study are to investigate oil recovery...

Li, Weiqiang

2011-02-22T23:59:59.000Z

293

Reducing emissions by addressing steam turbine inefficiencies  

SciTech Connect (OSTI)

This paper reports that inefficient steam turbines increase fossil plant emissions because additional fuel must be burned to meet the power output requirements. During a turbine outage, plant performance and maintenance staff make and prioritize repair decisions within tight time and budget constraints. This paper describes how Georgia Power identifies performance losses of degraded components in the steam path and determines their impact on heat rate. Turbine performance is assessed by a steam path audit program that Encotech has developed and make available to utilities. Georgia Power has conducted several operating tests that give good correlation with audit results. Georgia Power uses the audit information to make the most cost-effective repairs to maintain a low heat rate and to reduce emissions. The Clean Air Act presents electric utilities with the challenge of reducing emissions from fossil plants in the most cost-effective way possible. Meeting the stack emissions limitations often translates to large capital expenditures and increased cycle heat rate. One resource the electric utilities have to reduce the costly impact of compliance with the Clean Air Act is control over the efficiency of their steam turbines.

Harris, J.C. (Georgia Power Co., Atlanta, GA (United States)); Cioffi, D.H. (Encotech, Inc., Schenectady, NY (United States))

1992-01-01T23:59:59.000Z

294

Coreflood experimental study of steam displacement  

E-Print Network [OSTI]

The main objective of this study was to verify experimentally whether or not a Buckley-Leverett shock front exists when steam displaces oil in a porous medium, as assumed in the Aydelotte-Pope steamflood predictive model. Experiments were conducted...

Cerutti, Andres Enrique

1997-01-01T23:59:59.000Z

295

Design and Performance Aspects of Steam Generators  

E-Print Network [OSTI]

generators based on standard, pre-packaged designs. A "standard" boiler has several limitations such as pre-determined furnace dimensions, tube length, surface area, tube spacings etc, which may or may not be the optimum choice for a given steam demand...

Ganapathy, V.

296

Natural gas-assisted steam electrolyzer  

DOE Patents [OSTI]

An efficient method of producing hydrogen by high temperature steam electrolysis that will lower the electricity consumption to an estimated 65 percent lower than has been achievable with previous steam electrolyzer systems. This is accomplished with a natural gas-assisted steam electrolyzer, which significantly reduces the electricity consumption. Since this natural gas-assisted steam electrolyzer replaces one unit of electrical energy by one unit of energy content in natural gas at one-quarter the cost, the hydrogen production cost will be significantly reduced. Also, it is possible to vary the ratio between the electricity and the natural gas supplied to the system in response to fluctuations in relative prices for these two energy sources. In one approach an appropriate catalyst on the anode side of the electrolyzer will promote the partial oxidation of natural gas to CO and hydrogen, called Syn-Gas, and the CO can also be shifted to CO.sub.2 to give additional hydrogen. In another approach the natural gas is used in the anode side of the electrolyzer to burn out the oxygen resulting from electrolysis, thus reducing or eliminating the potential difference across the electrolyzer membrane.

Pham, Ai-Quoc (San Jose, CA); Wallman, P. Henrik (Berkeley, CA); Glass, Robert S. (Livermore, CA)

2000-01-01T23:59:59.000Z

297

Cash Flow Impacts of Industrial Steam Efficiency  

E-Print Network [OSTI]

is to overcome the perceptual barriers that preclude the approval of these initiatives. This article assumes that strong, financial justification is the key to the full realization of steam efficiency opportunities. That premise is followed by a step-wise review...

Russell, C.

298

Fuel cell integrated with steam reformer  

DOE Patents [OSTI]

A H.sub.2 -air fuel cell integrated with a steam reformer is disclosed wherein a superheated water/methanol mixture is fed to a catalytic reformer to provide a continuous supply of hydrogen to the fuel cell, the gases exhausted from the anode of the fuel cell providing the thermal energy, via combustion, for superheating the water/methanol mixture.

Beshty, Bahjat S. (Lower Makefield, PA); Whelan, James A. (Bricktown, NJ)

1987-01-01T23:59:59.000Z

299

Low chemical concentrating steam generating cycle  

DOE Patents [OSTI]

A steam cycle for a nuclear power plant having two optional modes of operation. A once-through mode of operation uses direct feed of coolant water to an evaporator avoiding excessive chemical concentration buildup. A recirculation mode of operation uses a recirculation loop to direct a portion of flow from the evaporator back through the evaporator to effectively increase evaporator flow.

Mangus, James D. (Greensburg, PA)

1983-01-01T23:59:59.000Z

300

Method of removing cesium from steam  

DOE Patents [OSTI]

Method for removal of radioactive cesium from a hot vapor, such as high temperature steam, including the steps of passing input hot vapor containing radioactive cesium into a bed of silicate glass particles and chemically incorporating radioactive cesium in the silicate glass particles at a temperature of at least about 700.degree. F.

Carson, Jr., Neill J. (Clarendon Hills, IL); Noland, Robert A. (Oak Park, IL); Ruther, Westly E. (Skokie, IL)

1991-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Task 1Steam Oxidation (NETL-US)  

SciTech Connect (OSTI)

The proposed steam in let temperature in the Advanced Ultra Supercritical (A稶SC) steam turbine is high enough (760癈) Ihat traditional turbine casing and valve body materials such as ferr;tic/manensitic steels will not suffice due to temperature lim itations of this class of materials. Cast versions of three traditionally wrought Ni-based superalloys (Haynes 263. Haynes 282, and Nimonic 105) were evaluated for use as casing or valve components for the next generation of industrial steam turbines. The full size castings are substantia l: 2-5,000 kg each half and on the order of 100 nun thick. Experimental castings were quite a bit smaller, but section size was retained and cooling rate controlled to produce equi valem microslruclUre . A multi_step homogenization heat treatment was d~ve loped to better disperse the al loy constituents. These castings were subsequently evaluated by characterizing their microstructure as well as their steam oxidation resistance (al 760 and 800 "C).

G. R. Holcomb

2010-05-01T23:59:59.000Z

302

Gas turbine row #1 steam cooled vane  

DOE Patents [OSTI]

A design for a vane segment having a closed-loop steam cooling system is provided. The vane segment comprises an outer shroud, an inner shroud and an airfoil, each component having a target surface on the inside surface of its walls. A plurality of rectangular waffle structures are provided on the target surface to enhance heat transfer between each component and cooling steam. Channel systems are provided in the shrouds to improve the flow of steam through the shrouds. Insert legs located in cavities in the airfoil are also provided. Each insert leg comprises outer channels located on a perimeter of the leg, each outer channel having an outer wall and impingement holes on the outer wall for producing impingement jets of cooling steam to contact the airfoil's target surface. Each insert leg further comprises a plurality of substantially rectangular-shaped ribs located on the outer wall and a plurality of openings located between outer channels of the leg to minimize cross flow degradation.

Cunha, Frank J. (Longwood, FL)

2000-01-01T23:59:59.000Z

303

Type A: Magma-heated, Dry Steam Resource | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:Seadov Pty LtdSteen,LtdInformationTulsa,TuscarawasFallon | OpenTyntek CorporationA:

304

DOE's BestPractices Steam End User Training Blowdown Losses 1  

E-Print Network [OSTI]

DOE's BestPractices Steam End User Training Blowdown Losses 1 June 28, 2010 Steam End User Training Steam Generation Module Steam EndUser Training Steam Generation Efficiency Module Blowdown affect on boiler efficiency. [Slide Visual 颅Blowdown Losses Title Page] Steam Generation Efficiency

Oak Ridge National Laboratory

305

REVIEW OF TRANSAMERICA DELAVAL INC. DIESEL GENERATOR OWNERS' GROUP ENGINE REQUALIFICATION PROGRAM  

SciTech Connect (OSTI)

In December 1983, 13 nuclear utilities that own TDI diesel generators formally established an Owners Group to address concerns regarding the reliability and operability of these engines. The Owners' Group program for engine requalification consisted of four major elements: 1) resolution of known problems with potentially generic implications, 2) a design review and quality revalidation (DR/QR) effort aimed at identifying and correcting potential problems with the important engine components, 3) expanded engine testing and inspection, and 4) enhanced engine maintenance and surveillance (M/S) to maintain the qualification of the diesel engines for the lifetime of the nuclear plants that they service. In providing technical support to NRC, the PNL project staff, assisted by a number of diesel engine consultants, focused on the four major elements of the Owners' Group engine requalification program, addressing both generic and plant-specific areas.

Berlinger, C. H.

1985-12-01T23:59:59.000Z

306

A comparison of noxious facilities` impacts for home owners versus renters  

SciTech Connect (OSTI)

The siting of noxious facilities, such as hazardous waste facilities, is often vigorously opposed by local residents. As a result, one would expect people`s residential and employment choices to reflect a desire to avoid proximity to such facilities. Ibis behavior would in turn affect labor and housing prices. One technique that has been employed to implicitly value impacts of noxious facilities is the intercity hedonic approach, which examines the wage and land rent differentials among cities that result from environmental amenities and disamenities. However, most of the research focus has been on the behavioral response of home owners as opposed to renters. Since these two groups of residents vary on numerous dimensions such as marital status, age, sex, and personal mobility, it would not be surprising to find different marginal valuations of local site characteristics. We use 1980 Census data to derive separate estimates for owners and renters of the implicit value placed on eight different types of noxious facilities. Although the magnitude of the responses of renters and owners to noxious facilities and other environmental characteristics varies, the signs are generally consistent. The differences in values between owners and renters are not primarily due to differential mobility or sociodemographic factors. Controlling those factors decreases the differences between renters` and owners` implicit valuations by less than 10%. Unmeasured differences in characteristics between the two groups, such as tastes, risk aversion, or commitment to the community, must account for the remaining difference in valuations. These findings suggest that policymakers should separately consider the responses of owners and renters when estimating noxious facility impacts.

Clark, D.E. [Marquette Univ., Milwaukee, WI (United States). Dept. of Economics]|[Argonne National Lab., IL (United States); Nieves, L.A. [Argonne National Lab., IL (United States)

1996-09-01T23:59:59.000Z

307

Steam gasification of carbon: Catalyst properties  

SciTech Connect (OSTI)

Coal gasification by steam is of critical importance in converting coal to gaseous products (CO, H[sub 2], CO[sub 2], CH[sub 4]) that can then be further converted to synthetic natural gas and higher hydrocarbon fuels. Alkali and alkaline earth metals (present as oxides) catalyze coal gasification reactions and cause them to occur at significantly lower temperatures. A more fundamental understanding of the mechanism of the steam gasification reaction and catalyst utilization may well lead to better production techniques, increased gasification rates, greater yields, and less waste. We are studying the gasification of carbon by steam in the presence of alkali and alkaline earth oxides, using carbonates as the starting materials. Carbon dioxide gasification (CO[sub 2] + C --> 2CO) has been studied in some detail recently, but much less has been done on the actual steam gasification reaction, which is the main thrust of our work. In particular, the form of the active catalyst compound during reaction is still questioned and the dependence of the concentration of active sites on reaction parameters is not known. Until recently, no measurements of active site concentrations during reaction had been made. We have recently used transient isotope tracing to determine active site concentration during CO[sub 2] gasification. We are investigating the mechanism and the concentration of active sites for steam gasification with transient isotopic tracing. For this technique, the reactant feed is switched from H[sub 2]0 to isotopically-labeled water at the same concentration and tow rate. We can then directly measure, at reaction the concentration of active catalytic sites, their kinetic rate constants, and the presence of more than one rate constant. This procedure allows us to obtain transient kinetic data without perturbing the steady-state surface reactions.

Falconer, J.L.

1993-01-10T23:59:59.000Z

308

A parametric study of steam injected gas turbine with steam injector  

SciTech Connect (OSTI)

The interest in the STIG concept has arisen from the fact that the application shows high flexibility in power output, and therefore can serve well as a peak load unit. A new addition to the STIG-cycle is proposed and investigated in this paper. The introduction of steam injectors at the injection point of the steam is proposed to lightly raise the pressure of the gas flow entering the expander. The injector reduces the thermodynamic irreversibilities associated with the throttling nature of injecting a high pressure steam into a lower pressure region. A thermodynamic study has been conducted on the STIG with steam injectors for power generation. Steam pressure and superheating temperature are the main parameters for the system. The impact and usefulness of supplementary firing before the HRSG has also been investigated. The results are compared with a STIG with throttling valves instead of injectors. The efficiency and power output proves to increase somewhat upon introducing the steam injectors. This modification can be of commercial interest since the injectors are of low installation cost and need virtually no maintenance.

Aagren, N.D.; Svedberg, G. [Royal Inst. of Technology, Stockholm (Sweden); Frutschi, H.U. [ABB Power Generation Ltd., Baden (Switzerland)

1994-12-31T23:59:59.000Z

309

Manganese and Ceria Sorbents for High Temperature Sulfur Removal from Biomass-Derived Syngas -- The Impact of Steam on Capacity and Sorption Mode  

SciTech Connect (OSTI)

Syngas derived from biomass and coal gasification for fuel synthesis or electricity generation contains sulfur species that are detrimental to downstream catalysts or turbine operation. Sulfur removal in high temperature, high steam conditions has been known to be challenging, but experimental reports on methods to tackle the problem are not often reported. We have developed sorbents that can remove hydrogen sulfide from syngas at high temperature (700 C), both in dry and high steam conditions. The syngas composition chosen for our experiments is derived from statistical analysis of the gasification products of wood under a large variety of conditions. The two sorbents, Cu-ceria and manganese-based, were tested in a variety of conditions. In syngas containing steam, the capacity of the sorbents is much lower, and the impact of the sorbent in lowering H{sub 2}S levels is only evident in low space velocities. Spectroscopic characterization and thermodynamic consideration of the experimental results suggest that in syngas containing 45% steam, the removal of H{sub 2}S is primarily via surface chemisorptions. For the Cu-ceria sorbent, analysis of the amount of H{sub 2}S retained by the sorbent in dry syngas suggests both copper and ceria play a role in H{sub 2}S removal. For the manganese-based sorbent, in dry conditions, there is a solid state transformation of the sorbent, primarily into the sulfide form.

Cheah, S.; Parent, Y. O.; Jablonski, W. S.; Vinzant, T.; Olstad, J. L.

2012-07-01T23:59:59.000Z

310

Consider Steam Turbine Drives for Rotating Equipment: Office of Industrial Technologies (OIT) Steam Tip Fact Sheet No.21  

SciTech Connect (OSTI)

Steam turbines are well suited as prime movers for driving boiler feedwater pumps, forced or induced-draft fans, blowers, air compressors, and other rotating equipment. This service generally calls for a backpressure non-condensing steam turbine. The low-pressure steam turbine exhaust is available for feedwater heating, preheating of deaerator makeup water, and/or process requirements.

Not Available

2002-01-01T23:59:59.000Z

311

Measurement of steam quality in two-phase critical flow  

E-Print Network [OSTI]

through a venturi for subczitical flow of steam-water 45 13 Steam quality as a function of vapor-phase Reynolds number for subczitical flow of steam-water 46 14 Steam quality as a function of Collins and Gacesa parameter for subcritical flow of steam... high degree of accuracy. He suggested that the following correlation may be used to calculate two-phase flow rates through orifices to within an error of 1. 5 percent 339 K 3 9 9' J 9 v v a v w f + [ 1. 26 (1-f ) K Y /K ] ~p p where V and L...

Sinclair, John William

2012-06-07T23:59:59.000Z

312

Thermochemically recuperated and steam cooled gas turbine system  

DOE Patents [OSTI]

A gas turbine system in which the expanded gas from the turbine section is used to generate the steam in a heat recovery steam generator and to heat a mixture of gaseous hydrocarbon fuel and the steam in a reformer. The reformer converts the hydrocarbon gas to hydrogen and carbon monoxide for combustion in a combustor. A portion of the steam from the heat recovery steam generator is used to cool components, such as the stationary vanes, in the turbine section, thereby superheating the steam. The superheated steam is mixed into the hydrocarbon gas upstream of the reformer, thereby eliminating the need to raise the temperature of the expanded gas discharged from the turbine section in order to achieve effective conversion of the hydrocarbon gas.

Viscovich, Paul W. (Longwood, FL); Bannister, Ronald L. (Winter Springs, FL)

1995-01-01T23:59:59.000Z

313

Thermochemically recuperated and steam cooled gas turbine system  

DOE Patents [OSTI]

A gas turbine system is described in which the expanded gas from the turbine section is used to generate the steam in a heat recovery steam generator and to heat a mixture of gaseous hydrocarbon fuel and the steam in a reformer. The reformer converts the hydrocarbon gas to hydrogen and carbon monoxide for combustion in a combustor. A portion of the steam from the heat recovery steam generator is used to cool components, such as the stationary vanes, in the turbine section, thereby superheating the steam. The superheated steam is mixed into the hydrocarbon gas upstream of the reformer, thereby eliminating the need to raise the temperature of the expanded gas discharged from the turbine section in order to achieve effective conversion of the hydrocarbon gas. 4 figs.

Viscovich, P.W.; Bannister, R.L.

1995-07-11T23:59:59.000Z

314

WORKING PAPER N 2013 11 The Grey Paradox: How Oil Owners Can Benefit  

E-Print Network [OSTI]

, Fossil Fuels, GlobalWarming, Non-renewable Resources, OPEC PARIS-JOURDAN SCIENCES ECONOMIQUES 48, BD, Fossil Fuels, Global Warming, Non-renewable Resources, OPEC. JEL Classication: H21, H23, Q31, Q38, Q41, Q of fossil-fuel owners de- pends on the characteristics of their fossil fuels (recoverable reserves

Paris-Sud XI, Universit茅 de

315

The Role of the Owners Rep for Energy Performance and Control  

E-Print Network [OSTI]

Many energy performance projects are unsuccessful due to a variety of confounding issues but most of them stem from the owner's lack of developing a solid team, a strong set of criteria for success, and a mechanism to ensure implementation success...

Bernstein, R.

2012-01-01T23:59:59.000Z

316

A unique program for horse business owners Tuesdays, February 5 -March 19 (seven weeks)  

E-Print Network [OSTI]

A unique program for horse business owners Tuesdays, February 5 - March 19 (seven weeks) 6:00pm 颅 9 budgeting plan by the end of the seven-week course. The course is offered by Dr. Carey Williams, Equine@njaes.rutgers.edu, 848-932-3229 $70.00 per person Dinner and Companion workbook included. Equine Business Planning Course

Goodman, Robert M.

317

Tour of Entergy's Nuclear Power Plant in River Bend Owner: Entergy Gulf States Inc.  

E-Print Network [OSTI]

Tour of Entergy's Nuclear Power Plant in River Bend Owner: Entergy Gulf States Inc. Reactor Type a nuclear power plant. Plant was Entergy, a Boiling Water Reactor (BWR) type. Built in the 80's, it has of the veteran plant workers. The presentation gave the nuclear plant engineering basics and built

Ervin, Elizabeth K.

318

AIM: A Home-Owner Usable Energy Calculator for Existing Residential Homes  

E-Print Network [OSTI]

An energy efficiency metric for residential homes was developed to provide home-owners, realtors and builders a method to rate the energy efficiency of an existing house. To accomplish this, a web-based calculator was developed, which is based...

Marshall, K.; Moss, M.; Malhotra, M.; Liu, B.; Culp, C.; Haberl, J.; Herbert, C.

319

Large steam turbine repair: A survey  

SciTech Connect (OSTI)

This report covers a survey taken to document the current state-of-the-art in repairs to large steam turbines. One objective was to provide information to assist utilities in making repair or replacement decisions. The survey revealed that a large number of repairs have been successfully repaired involving both mechanical and welding repair techniques. Repair techniques have been improving in recent years and are being used more frequently. No guidelines or codes exist for the repair of steam turbine components so each repair is primarily controlled by agreement between the utility, contractor and insurer. Types of repairs are reviewed in this report and in addition, the capabilities of various contractors who are currently active in providing repair service. 40 refs., 10 figs., 4 tabs.

Findlan, S.J.; Lube, B. (EPRI Nondestructive Evaluation Center, Charlotte, NC (United States))

1991-07-01T23:59:59.000Z

320

Steam turbine/generator NDE workshop  

SciTech Connect (OSTI)

On September 12--15, 1989, EPRI sponsored a workshop in Charlotte, North Carolina on steam turbine/generator rotating components. The approximate 185 attendees represented a broad spectrum of utilities, equipment manufactures, forging suppliers, service organizations, universities, insurance carriers, and consultants from the United States and abroad. Canada, England, Finland, France, Germany, Japan, Korea, Italy, Spain, and Sweden were represented at the workshop, and 81 of the attendees represented 44 domestic utilities. Nondestructive examination equipment demonstrations by 16 vendors and 2 utilities at the EPRI NDE Center complemented the technical presentation. In addition to 23 formal, technical presentations of prepared papers of specific topics, 8 tutorial presentations, plus various opening and closing remarks and addresses, were given at the workshop. Presentations were organized under the following general topics: bucket blades and/or attachment regions; retaining rings; wheels/disks; steam turbine/generator testing and evaluation; and tutorials. Each individual paper has been cataloged separately.

Nottingham, L.D.; Sabourin, P.F. (Jones (J.A.) Applied Research Co., Charlotte, NC (USA))

1990-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Artificial Intelligence Techniques for Steam Generator Modelling  

E-Print Network [OSTI]

This paper investigates the use of different Artificial Intelligence methods to predict the values of several continuous variables from a Steam Generator. The objective was to determine how the different artificial intelligence methods performed in making predictions on the given dataset. The artificial intelligence methods evaluated were Neural Networks, Support Vector Machines, and Adaptive Neuro-Fuzzy Inference Systems. The types of neural networks investigated were Multi-Layer Perceptions, and Radial Basis Function. Bayesian and committee techniques were applied to these neural networks. Each of the AI methods considered was simulated in Matlab. The results of the simulations showed that all the AI methods were capable of predicting the Steam Generator data reasonably accurately. However, the Adaptive Neuro-Fuzzy Inference system out performed the other methods in terms of accuracy and ease of implementation, while still achieving a fast execution time as well as a reasonable training time.

Wright, Sarah

2008-01-01T23:59:59.000Z

322

Propellant actuated nuclear reactor steam depressurization valve  

DOE Patents [OSTI]

A nuclear fission reactor combined with a propellant actuated depressurization and/or water injection valve is disclosed. The depressurization valve releases pressure from a water cooled, steam producing nuclear reactor when required to insure the safety of the reactor. Depressurization of the reactor pressure vessel enables gravity feeding of supplementary coolant water through the water injection valve to the reactor pressure vessel to prevent damage to the fuel core.

Ehrke, Alan C. (San Jose, CA); Knepp, John B. (San Jose, CA); Skoda, George I. (Santa Clara, CA)

1992-01-01T23:59:59.000Z

323

Materials Performance in USC Steam Portland  

SciTech Connect (OSTI)

Goals of the U.S. Department of Energy's Advanced Power Systems Initiatives include power generation from coal at 60% efficiency, which requires steam conditions of up to 760 C and 340 atm, co-called advanced ultrasupercritical (A-USC) steam conditions. A limitation to achieving the goal is a lack of cost-effective metallic materials that can perform at these temperatures and pressures. Some of the more important performance limitations are high-temperature creep strength, fire-side corrosion resistance, and steam-side oxidation resistance. Nickel-base superalloys are expected to be the materials best suited for steam boiler and turbine applications above about 675 C. Specific alloys of interest include Haynes 230 and 282, Inconel 617, 625 and 740, and Nimonic 263. Further validation of a previously developed chromia evaporation model is shown by examining the reactive evaporation effects resulting from exposure of Haynes 230 and Haynes 282 to moist air environments as a function of flow rate and water content. These two alloys differ in Ti and Mn contents, which may form outer layers of TiO{sub 2} or Cr-Mn spinels. This would in theory decrease the evaporation of Cr{sub 2}O{sub 3} from the scale by decreasing the activity of chromia at the scale surface, and be somewhat self-correcting as chromia evaporation concentrates the Ti and Mn phases. The apparent approximate chromia activity was found for each condition and alloy that showed chromia evaporation kinetics. As expected, it was found that increasing the gas flow rate led to increased chromia evaporation and decreased chromia activity. However, increasing the water content in moist air increased the evaporation, but results were mixed with its effect on chromia activity.

G.R. Holcomb; J. Tylczak; R. Hu

2011-04-26T23:59:59.000Z

324

Laser removal of sludge from steam generators  

DOE Patents [OSTI]

A method of removing unwanted chemical deposits known as sludge from the metal surfaces of steam generators with laser energy is provided. Laser energy of a certain power density, of a critical wavelength and frequency, is intermittently focused on the sludge deposits to vaporize them so that the surfaces are cleaned without affecting the metal surface (sludge substrate). Fiberoptic tubes are utilized for laser beam transmission and beam direction. Fiberoptics are also utilized to monitor laser operation and sludge removal.

Nachbar, Henry D. (Ballston Lake, NY)

1990-01-01T23:59:59.000Z

325

The Economics of Steam Electric Generation  

E-Print Network [OSTI]

by manufacturers, data available from past installations and recent installations. 7) Labor costs were based on labor rates in ~he Lansing, Michigan area. 8) Power plant labor and supervision costs were based on manning data supplied by the Board of Water...-service. No other figures, including labor, fuel cost, outside services and other costs have been escalated. 12) Operating costs were established, based on steam generation. Credit has been allotted to any program for the electric power generated during...

Ophaug, R. A.; Birget, C. D.

1980-01-01T23:59:59.000Z

326

Steam Generator Group Project. Annual report, 1982  

SciTech Connect (OSTI)

The Steam Generator Group Project (SGGP) is an NRC program joined by additional sponsors. The SGGP utilizes a steam generator removed from service at a nuclear plant (Surry 2) as a vehicle for research on a variety of safety and reliability issues. This report is an annual summary of progress of the program for 1982. Information is presented on the Steam Generator Examination Facility (SGEF), especially designed and constructed for this research. Loading of the generator into the SGEF is then discussed. The report then presents radiological field mapping results and personnel exposure monitoring. This is followed by information on field reduction achieved by channel head decontaminations. The report then presents results of a secondary side examination through shell penetrations placed prior to transport, confirming no change in generator condition due to transport. Decontamination of the channel head is discussed followed by plans for eddy current testing and removal of the plugs placed during service. Results of a preliminary profilometry examination are then provided.

Clark, R.A.; Lewis, M.

1984-02-01T23:59:59.000Z

327

Measuring non-condensable gases in steam  

SciTech Connect (OSTI)

In surgery, medical devices that are used should be sterilized. To obtain surface steam sterilization conditions, not only in the sterilizer chamber itself but also in the loads to be sterilized, the amount of non-condensable gases (NCGs), for instance air, should be very low. Even rather small fractions of NCGs (below 1%) seriously hamper steam penetration in porous materials or devices with hollow channels (e.g., endoscopes). A recently developed instrument which might detect the presence of residual NCGs in a reliable and reproducible way is the 3M{sup TM} Electronic Test System (ETS). In this paper, a physical model is presented that describes the behavior of this instrument. This model has been validated by experiments in which known fractions of NCGs were introduced in a sterilizer chamber in which an ETS was placed. Despite several approximations made in the model, a good agreement is found between the model predictions and the experimental results. The basic principle of the ETS, measuring the heat transfer by condensation on a cooled surface, permits a very sensitive detection of NCGs in harsh environments like water vapor at high temperatures and pressures. Our model may serve to develop adapted and optimized versions of this instrument for use outside the field of sterilization, e.g., in heat exchangers based on steam condensation.

Doornmalen, J. P. C. M. van; Kopinga, K., E-mail: k.kopinga@tue.nl [Department of Applied Physics, Eindhoven University of Technology, P.O. Box 513, 5600 MB Eindhoven (Netherlands)

2013-11-15T23:59:59.000Z

328

Steam generator operating experience, update for 1989--1990  

SciTech Connect (OSTI)

This report summarizes operational events and degradation mechanisms affecting pressurized water reactor steam generator integrity. It provides: results of 1989 and 1990 steam generator inspections; highlights prevalent problem areas; improvements that have been made in nondestructive testing methods; preventive measures; repair techniques; and replacement procedures. It describes the equipment of the three (3) major suppliers and discusses recent examinations of 76 plants. Major areas of concern are the steam generator degradation mechanisms that affect tube integrity or cause tube leakage and tube failure. These include; (1) intergranular attack (IGA); (2) intergranular stress corrosion cracking (IGSCC); (3) primary water stress corrosion cracking (PWSCC); (4) pitting; and (5) vibrational wear and fatigue. Also discussed are plugging, sleeving, heat treatment, peening, chemical cleaning, and steam generator replacements. The current status of regulatory instruments and inspection guidelines for ensuring the steam generator integrity, is discussed with the highlights of steam generator research. New potential safety issues such as circumferential cracking and tube plug cracking are also discussed.

Frank, L.

1991-12-01T23:59:59.000Z

329

Comments on US LMFBR steam generator base technology  

SciTech Connect (OSTI)

The development of steam generators for the LMFBR was recognized from the onset by the AEC, now DOE, as a difficult, challenging, and high-priority task. The highly reactive nature of sodium with water/steam requires that the sodium-water/steam boundaries of LMFBR steam generators possess a degree of leak-tightness reliability not normally attempted on a commercial scale. In addition, the LMFBR steam generator is subjected to high fluid temperatures and severe thermal transients. These requirements place great demand on materials, fabrication processes, and inspection methods; and even greater demands on the designer to provide steam generators that can meet these demanding requirements, be fabricated without unreasonable shop requirements, and tolerate off-normal effects.

Simmons, W.R.

1984-01-01T23:59:59.000Z

330

Review of High Temperature Water and Steam Cooled Reactor Concepts  

SciTech Connect (OSTI)

This review summarizes design concepts of supercritical-pressure water cooled reactors (SCR), nuclear superheaters and steam cooled fast reactors from 1950's to the present time. It includes water moderated supercritical steam cooled reactor, SCOTT-R and SC-PWR of Westinghouse, heavy water moderated light water cooled SCR of GE, SCLWR and SCFR of the University of Tokyo, B-500SKDI of Kurchatov Institute, CANDU -X of AECL, nuclear superheaters of GE, subcritical-pressure steam cooled FBR of KFK and B and W, Supercritical-pressure steam cooled FBR of B and W, subcritical-pressure steam cooled high converter by Edlund and Schultz and subcritical-pressure water-steam cooled FBR by Alekseev. This paper is prepared based on the previous review of SCR2000 symposium, and some author's comments are added. (author)

Oka, Yoshiaki [Nuclear Engineering Research Laboratory, The University of Tokyo, 3-1, Hongo 7-Chome, Bunkyo-ku (Japan)

2002-07-01T23:59:59.000Z

331

High-intensity drying processes: Impulse drying. Annual report  

SciTech Connect (OSTI)

Experiments were conducted on a sheet-fed pilot-scale shoe press to compare impulse drying and double-felted pressing. Both an IPST (Institute of Paper Science and Technology) ceramic coated and Beloit Type A press roll were evaluated for lienrboard sheet structures having a wide range of z-direction permeability. Purpose was to find ways of correcting sheet sticking problems observed in previous pilot-scale shoe press experiments. Results showed that impulse drying was superior to double felted pressing in both press dryness and in important paper physical properties. Impulse drying critical temperature was found to depend on specific surface of the heated layer of the sheet, thermal properties of the press roll surface, and choice of felt. Impulse drying of recycled and two-ply liner was demonstrated for both Southern Pile and Douglas fir-containing furnishes.

Orloff, D.I.; Phelan, P.M.

1993-12-01T23:59:59.000Z

332

The Engineered Approach to Energy and Maintenance Effective Steam Trapping  

E-Print Network [OSTI]

., Chemical Engineering 9/1/75. 4. Maintenance Engineering, May 1976. 5. "How Much Does Lost Steam Cost",Armstrong Machine works, Hydrocarbon Processing, p.129, Jan. 1976. 6. "Setter Steam Trapping Cuts Energy Waste", wesley Yates, Yarway Corp..., Georgia Tech Industrial Energy Extension Service, Chemical Engineering, 2/11/80. 10. ''Basic Facts & Enerqv Saving Tips" ,Lawrence R. O'Dell, Armstrong Machine Works, Heating/Piping/ Air Conditioning, May 1977. 11. Steam Trap Report - Energy Loss...

Krueger, R. G.; Wilt, G. W.

1980-01-01T23:59:59.000Z

333

An experimental and mathematical investigation of hydrocarbon steam distillation  

E-Print Network [OSTI]

of Committee) Dr. Pau B. Crawford (Member) r. William D. McCain Jr. r. A ber t T. Watson (Member) Dr. i l. iam D. on Gonten ead of Department) December 1984 ABSTRACT An Experimental and Mathematical Investigation of Hydrocarbon Steam Distillation... mechanism associated with steam flooding and in-situ combustion enhanced oil recovery projects. It also takes place in hydrocarbon recovery from deep volatile oil reservoirs. Nethods for predicting the recovery of hydrocarbons by steam distillation have...

Langhoff, John Allan

1984-01-01T23:59:59.000Z

334

Steam generator for liquid metal fast breeder reactor  

DOE Patents [OSTI]

Improvements in the design of internal components of J-shaped steam generators for liquid metal fast breeder reactors. Complex design improvements have been made to the internals of J-shaped steam generators which improvements are intended to reduce tube vibration, tube jamming, flow problems in the upper portion of the steam generator, manufacturing complexities in tube spacer attachments, thermal stripping potentials and difficulties in the weld fabrication of certain components.

Gillett, James E. (Greensburg, PA); Garner, Daniel C. (Murrysville, PA); Wineman, Arthur L. (Greensburg, PA); Robey, Robert M. (North Huntingdon, PA)

1985-01-01T23:59:59.000Z

335

Reliability Improvement Programs in Steam Distribution and Power Generation Systems  

E-Print Network [OSTI]

RELIABILITY IIIPROVEfWlT PROGRAMS IN STEAM DISTRIBUTION AND POVER GENERATION SYSTEItS Steve Petto Tech/Serv Corporation Blue Bell, PA Abstract This paper will present alternatives to costly corrective maintenance of the steam trap... In the reliability and efficiency of the system. Recent studies have shownt hat more than 40% of all In stalled steam traps and 20% of certain types of valves need some form of corrective action. The majority of all high backpressure problems In condensate return...

Petto, S.

336

Steam-Electric Power-Plant-Cooling Handbook  

SciTech Connect (OSTI)

The Steam-Electric Power Plant Cooling Handbook provides summary data on steam-electric power plant capacity, generation and number of plants for each cooling means, by Electric Regions, Water Resource Regions and National Electric Reliability Council Areas. Water consumption by once-through cooling, cooling ponds and wet evaporative towers is discussed and a methodology for computation of water consumption is provided for a typical steam-electric plant which uses a wet evaporative tower or cooling pond for cooling.

Sonnichsen, J.C.; Carlson, H.A.; Charles, P.D.; Jacobson, L.D.; Tadlock, L.A.

1982-02-01T23:59:59.000Z

337

g:\\fpdc\\contracts unit\\consultant selection and agreement forms\\consultant agreements\\owner consultant agreement final pdc.doc Page 1 of 24  

E-Print Network [OSTI]

\\owner consultant agreement final pdc.doc Page 1 of 24 MONTANA STATE UNIVERSITY PLANNING, DESIGN & CONSTRUCTION 6TH forms\\consultant agreements\\owner consultant agreement final pdc.doc Page 2 of 24 TABLE OF CONTENTS PART\\consultant selection and agreement forms\\consultant agreements\\owner consultant agreement final pdc.doc Page 3 of 24 1

Dyer, Bill

338

Carbon Dioxide Capture from Flue Gas Using Dry, Regenerable Sorbents  

SciTech Connect (OSTI)

This report describes research conducted between July 1, 2006 and September 30, 2006 on the use of dry regenerable sorbents for removal of carbon dioxide (CO{sub 2}) from coal combustion flue gas. Modifications to the integrated absorber/ sorbent regenerator/ sorbent cooler system were made to improve sorbent flow consistency and measurement reliability. Operation of the screw conveyor regenerator to achieve a sorbent temperature of at least 120 C at the regenerator outlet is necessary for satisfactory carbon dioxide capture efficiencies in succeeding absorption cycles. Carbon dioxide capture economics in new power plants can be improved by incorporating increased capacity boilers, efficient flue gas desulfurization systems and provisions for withdrawal of sorbent regeneration steam in the design.

David A. Green; Thomas O. Nelson; Brian S. Turk; Paul D. Box Raghubir P. Gupta

2006-09-30T23:59:59.000Z

339

Droplet Characterization in the Wake of Steam Turbine Cascades.  

E-Print Network [OSTI]

?? In low-pressure steam turbines, water droplet formation on the surfaces of stationary stator blades can lead to erosion on downstream turbine blades and other (more)

Plondke, Adam Charles

2012-01-01T23:59:59.000Z

340

Steam generator operating experience update, 1982-1983. [PWR  

SciTech Connect (OSTI)

This report is a continuation of earlier reports by the staff addressing pressurized water reactor steam generator operating experience. NUREG-0886, Steam Generator Tube Experience, published in February 1982 summarized experience in domestic and foreign plants through December 1981. This report summarizes steam generator operating experience in domestic plants for the years 1982 and 1983. Included are new problems encountered with secondary-side loose parts, sulfur-induced stress-assisted corrosion cracking, and flow-induced vibrational wear in the new preheater design steam generators. The status of Unresolved Safety Issues A3, A4, and A5 is also discussed.

Frank, L.

1984-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Steam System Opportunity Assessment for the Pulp and Paper, Chemical...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

System Opportunity Assessment for the Pulp and Paper, Chemical Manufacturing, and Petroleum Refining Industries Steam System Opportunity Assessment for the Pulp and Paper,...

342

Y-12 Steam Plant Project Received National Recognition for Project...  

National Nuclear Security Administration (NNSA)

Steam Plant Project Received National Recognition for Project Management Excellence | National Nuclear Security Administration Facebook Twitter Youtube Flickr RSS People Mission...

343

Recent Progress on Steam Hydrogasification of Carbonaceous Matter...  

Broader source: Energy.gov (indexed) [DOE]

Progress on Steam Hydrogasification of Carbonaceous Matter to Clean Synthetic Diesel Fuel Surinder P. Singh, Arun Raju, Chan Seung Park, Joe Norbeck University of California,...

344

Steam Plant Operator (2nd Shift) | Princeton Plasma Physics Lab  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Steam Plant Operator (2nd Shift) Department: Facilities Supervisor(s): Willam Gervasi Staff: L&S 5 Requisition Number: 1500061 Obtain the necessary skills and theoretical knowledge...

345

Fluidized Bed Steam Reforming of INEEL SBW Using THORsm Mineralizing Technology  

SciTech Connect (OSTI)

Sodium bearing waste (SBW) disposition is one of the U.S. Department of Energy (DOE) Idaho Operation Office抯 (NE-ID) and State of Idaho抯 top priorities at the Idaho National Engineering and Environmental Laboratory (INEEL). Many studies have resulted in the identification of five treatment alternatives that form a short list of perhaps the most appropriate technologies for the DOE to select from. The alternatives are (a) calcination with maximum achievable control technology (MACT) upgrade, (b) steam reforming, (c) cesium ion exchange (CsIX) with immobilization, (d) direct evaporation, and (e) vitrification. Each alternative has undergone some degree of applied technical development and preliminary process design over the past four years. DOE desired further experimental data, with regard to steam reforming technology, to make informed decisions concerning selection of treatment technology for SBW. Mineralizing steam reforming technology, offered by THOR Treatment Technologies, LLC would produce a denitrated, granular mineral waste form using a high-temperature fluidized bed process. A pilot scale demonstration of the technology was performed in a 15-cm-diameter reactor vessel September 27 through October 1, 2004. The pilot scale equipment is owned by the DOE, and located at the Science and Technology Applications Research (STAR) Center in Idaho Falls, ID. Flowsheet chemistry and operational parameters were defined through a collaborative effort involving Idaho National Engineering and Environmental Laboratory, Savannah River National Laboratory (SRNL), and THOR Treatment Technologies personnel. Personnel from Science Applications International Corporation, owners of the STAR Center, operated the pilot plant. The pilot scale test was terminated as planned after achieving a total of 100 hrs of cumulative/continuous processing operation. About 230 kg of SBW surrogate were processed that resulted in about 88 kg of solid product, a mass reduction of about 62%. The process achieved about a 90% turnover of the starting bed. Samples of mineralized solid product materials were analyzed for chemical/physical properties. Results of product performance testing conducted by SRNL will be reported separately by SRNL.

Arlin L. Olson; Nicholas R. Soelberg; Douglas W. Marshall; Gary L. Anderson

2004-12-01T23:59:59.000Z

346

Sustaining dry surfaces under water  

E-Print Network [OSTI]

Rough surfaces immersed under water remain practically dry if the liquid-solid contact is on roughness peaks, while the roughness valleys are filled with gas. Mechanisms that prevent water from invading the valleys are well studied. However, to remain practically dry under water, additional mechanisms need consideration. This is because trapped gas (e.g. air) in the roughness valleys can dissolve into the water pool, leading to invasion. Additionally, water vapor can also occupy the roughness valleys of immersed surfaces. If water vapor condenses, that too leads to invasion. These effects have not been investigated, and are critically important to maintain surfaces dry under water. In this work, we identify the critical roughness scale below which it is possible to sustain the vapor phase of water and/or trapped gases in roughness valleys - thus keeping the immersed surface dry. Theoretical predictions are consistent with molecular dynamics simulations and experiments.

Paul R. Jones; Xiuqing Hao; Eduardo R. Cruz-Chu; Konrad Rykaczewski; Krishanu Nandy; Thomas M. Schutzius; Kripa K. Varanasi; Constantine M. Megaridis; Jens H. Walther; Petros Koumoutsakos; Horacio D. Espinosa; Neelesh A. Patankar

2014-09-29T23:59:59.000Z

347

Steam Oxidation of Fossil Power Plant Materials: Collaborative Research to Enable Advanced Steam Power Cycles  

DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

Research into improved materials systems and associated manufacturing and reliability issues is a major part of initiatives to produce cleaner and cheaper energy systems in the UK and the USA. Under the auspices of a Memorandum of Understanding on Energy R&D, a work programme concerned with steam oxidation has been conducted. The focus was on the generation of definitive information regarding the oxidation behaviour in steam of current and developmental ferritic steels, austenitic steels, and nickelbased alloys required to enable advanced steam power cycles. The results were intended to provide a basis for quantifying the rate of metal loss expected under advanced steam cycle conditions, as well as understanding of the evolution of oxide scale morphologies with time and temperature to identify features that could influence scale exfoliation characteristics. This understanding and acquired data were used to develop and validate models of oxide growth and loss by exfoliation. This paper provides an overview of the activity and highlights a selection of the results coming from the programme.

A. T. Fry; I. G Wright; N. J Simms; B. McGhee; G. R. Holcomb

2013-11-19T23:59:59.000Z

348

Potential applications of microscopy for steam coal  

SciTech Connect (OSTI)

Optical microscopy has been an extremely useful tool for many industrial sectors in the past. This paper introduces some of the potential applications of using coal and fly ash carbon microscopy for the combustion process and steam coal industry. Coal and fly ash carbon microscopic classification criteria are described. Plant sample data are presented which demonstrate that these techniques can be useful for coal selection and for problem solving in the coal-fired power plant environment. Practical recommendations for further study are proposed.

DeVanney, K.F.; Clarkson, R.J.

1995-08-01T23:59:59.000Z

349

Baton Rouge Complex Steam Real Time Optimization  

E-Print Network [OSTI]

Baton Rouge Complex Steam Real Time Optimization IETC 2014 New Orleans, Louisiana Tope Iyun ExxonMobil Chemical Company May 22, 2014 ESL-IE-14-05-32 Proceedings of the Thrity-Sixth Industrial Energy Technology Conference New Orleans, LA. May 20... were generated by or on behalf of ExxonMobil Chemical Company. Legal Disclosures 2014 ExxonMobil. To the extent the user is entitled to disclose and distribute this document, the user may forward, distribute, and/or photocopy this copyrighted...

Iyun, T.

2014-01-01T23:59:59.000Z

350

Warm or Steaming Ground | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:Seadov PtyInformationSEDS data JumpWakullaWanxiang ElectricFacility | Openor Steaming

351

Desulfurization of lignite using steam and air  

E-Print Network [OSTI]

with nitrogen to remove oxygen and then the drums were sealed until needed for a run. This procedure was used to prevent weathering and loss of moisture from the coal. Prior to charging, t' he lignite was sized to minus 18 mesh. The larg- er particles...DESULFURIZATION OF LIGNITE USING STEAM AND AIR A Thesis by GLENN ALLEN CARTER, JR. Submitted to the Graduate College of Texas A&M University in partial fulfillment of the degree of MASTER OF SCIENCE August 1982 Major Subject: Chemical...

Carter, Glenn Allen

1982-01-01T23:59:59.000Z

352

The value of steam turbine upgrades  

SciTech Connect (OSTI)

Technological advances in mechanical and aerodynamic design of the turbine steam path are resulting in higher reliability and efficiency. A recent study conducted on a 390 MW pulverized coal-fired unit revealed just how much these new technological advancements can improve efficiency and output. The empirical study showed that the turbine upgrade raised high pressure (HP) turbine efficiency by 5%, intermediate pressure (IP) turbine efficiency by 4%, and low pressure (LP) turbine efficiency by 2.5%. In addition, the unit's highest achievable gross generation increased from 360 MW to 371 MW. 3 figs.

Potter, K.; Olear, D.; [General Physics Corp. (United States)

2005-11-01T23:59:59.000Z

353

Flash Steam Power Plant | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdfNotify98.pdf Jump to:Siting.pdfFiskdale,Five StarFlash Steam Power Plant

354

Flash Steam Power Plant | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublicIDAPowerPlantSitingConstruction.pdfNotify98.pdf Jump to:Siting.pdfFiskdale,Five StarFlash Steam Power

355

Apparatus and methods for supplying auxiliary steam in a combined cycle system  

DOE Patents [OSTI]

To provide auxiliary steam, a low pressure valve is opened in a combined cycle system to divert low pressure steam from the heat recovery steam generator to a header for supplying steam to a second combined cycle's steam turbine seals, sparging devices and cooling steam for the steam turbine if the steam turbine and gas turbine lie on a common shaft with the generator. Cooling steam is supplied the gas turbine in the combined cycle system from the high pressure steam turbine. Spent gas turbine cooling steam may augment the low pressure steam supplied to the header by opening a high pressure valve whereby high and low pressure steam flows are combined. An attemperator is used to reduce the temperature of the combined steam in response to auxiliary steam flows above a predetermined flow and a steam header temperature above a predetermined temperature. The auxiliary steam may be used to start additional combined cycle units or to provide a host unit with steam turbine cooling and sealing steam during full-speed no-load operation after a load rejection.

Gorman, William G. (Ballston Spa, NY); Carberg, William George (Ballston Spa, NY); Jones, Charles Michael (Ballston Lake, NY)

2002-01-01T23:59:59.000Z

356

Economics of high performance steam systems (HPSS) cogeneration: A handbook  

SciTech Connect (OSTI)

This guidebook aims to farther industry's knowledge of HPSS and their potential benefits. It is also intended to provide industrial end-users with a basis for judging the merits of HPSS under various site-specific conditions by outlining the economics of HPSS and conventional cogeneration systems compared to boilers under representative sets of industrial process conditions. Electric utility companies have experimented with steam pressures in the range of 5,000 psig and temperatures up to 1,200[degrees]F, but generally have remained with more conservative throttle conditions of 2,400 psig, 1,000[degrees]F to improve reliability. Most industrial applications have used steam throttle conditions below 900 psig and 900[degrees]F. Yet thermodynamic analysis shows that in a steam turbine generator, the amount of electricity generated per pound of steam increases as the inlet steam temperature and pressure are increased. Furthermore, the incremental electricity that is generated by raising the steam temperature and pressure is produced in a highly efficient manner. Efforts in this direction explain why, recently, some industrial projects have been built with steam turbine inlet turbine conditions of 1,500 psig and above. The HPSS concept goes one step further: It is based on a high-temperature steam generator capable of producing 1,500[degrees]F superheated steam and a high-speed steam turbine-generator. By utilizing the HPSS system as a topping'' system, high-pressure steam can be expanded from 1,500[degrees]F to the traditional temperatures used by industry.

Not Available

1992-06-01T23:59:59.000Z

357

Economics of high performance steam systems (HPSS) cogeneration: A handbook  

SciTech Connect (OSTI)

This guidebook aims to farther industry`s knowledge of HPSS and their potential benefits. It is also intended to provide industrial end-users with a basis for judging the merits of HPSS under various site-specific conditions by outlining the economics of HPSS and conventional cogeneration systems compared to boilers under representative sets of industrial process conditions. Electric utility companies have experimented with steam pressures in the range of 5,000 psig and temperatures up to 1,200{degrees}F, but generally have remained with more conservative throttle conditions of 2,400 psig, 1,000{degrees}F to improve reliability. Most industrial applications have used steam throttle conditions below 900 psig and 900{degrees}F. Yet thermodynamic analysis shows that in a steam turbine generator, the amount of electricity generated per pound of steam increases as the inlet steam temperature and pressure are increased. Furthermore, the incremental electricity that is generated by raising the steam temperature and pressure is produced in a highly efficient manner. Efforts in this direction explain why, recently, some industrial projects have been built with steam turbine inlet turbine conditions of 1,500 psig and above. The HPSS concept goes one step further: It is based on a high-temperature steam generator capable of producing 1,500{degrees}F superheated steam and a high-speed steam turbine-generator. By utilizing the HPSS system as a ``topping`` system, high-pressure steam can be expanded from 1,500{degrees}F to the traditional temperatures used by industry.

Not Available

1992-06-01T23:59:59.000Z

358

Development and Application of Advanced Models for Steam Hydrogasification: Process Design and Economic Evaluation  

E-Print Network [OSTI]

Power generation (MW) Gas turbine Steam turbine Total Naphtha DieselPower generation (MW) CERT-1 Gas turbine Steam turbine Total Naphtha DieselPower generation (MW) Gas turbine CERT-2 CERT-2B Steam turbine Total Naphtha Diesel

Lu, Xiaoming

2012-01-01T23:59:59.000Z

359

EVALUATION OF A SULFUR OXIDE CHEMICAL HEAT STORAGE PROCESS FOR A STEAM SOLAR ELECTRIC PLANT  

E-Print Network [OSTI]

Distillation column Steam turbine Condenser load. CalculatesHeat Trimmer Dist. Condenser Turbine Steam Leaks LP TurbineRH ll~ PRESSURE STEAM FLOW INTO CONDENSER *STC D12 PRE! SURE

Dayan, J.

2011-01-01T23:59:59.000Z

360

E-Print Network 3.0 - a-3 chemical steam Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

a large number of buildings are heated from a central source by conveying steam or hot water... of steam, such as the Con Edison Steam DH system in New York City and the ......

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

EVALUATION OF A SULFUR OXIDE CHEMICAL HEAT STORAGE PROCESS FOR A STEAM SOLAR ELECTRIC PLANT  

E-Print Network [OSTI]

IOUT *MEBP *STC(QAAN. R )-STEAM TURBINE CALC. ~ETFQMIN~5 ST~KJ/S) 1JC. /(GROSS STEAM TURBINE POWER PRODUCTION) STEA~ GENprogram then prints the steam turbine results. All flows in

Dayan, J.

2011-01-01T23:59:59.000Z

362

Experimental study of Morichal heavy oil recovery using combined steam and propane injection  

E-Print Network [OSTI]

with steam (for the purpose of increasing steam recovery efficiency) are being evaluated. An experimental study has been performed to investigate the effect of combined steam and propane injection on recovery of heavy oil from the Morichal field, Venezuela...

Goite Marcano, Jose Gregorio

1999-01-01T23:59:59.000Z

363

Steam vacuum cleaning. Innovative technology summary report  

SciTech Connect (OSTI)

The US Department of Energy (DOE) continually seeks safer and more cost-effective remediation technologies for use in the decontamination and decommissioning (D and D) of nuclear facilities. The baseline technology currently used for washing debris is a high-pressure water cleaning (HPWC) system. The system used at the FEMP is the Hotsy{reg_sign} Model 550B HPWC. Although the HPWC technology has functioned satisfactorily, improvements are being sought in areas related to reduced liquid waste volume, increased productivity, increased washing effectiveness, and decreased airborne contamination. An innovative technology that offers potential improvements in these areas is a steam vacuum cleaning (SVC) system that integrates high-pressure steam cleaning with a vacuum recovery sub-system that simultaneously collects dislodged contaminants thereby reducing airborne contamination. The SVC system selected for demonstration at the FEMP was the Kelly{trademark} Decontamination System shown. This report provides comparative performance and cost analyses between the Hotsy HPWC system and the Kelly Decontamination System. Both technologies were demonstrated at the FEMP site located at Fernald, Ohio from July 29, 1996 through August 15, 1996. The demonstrations were conducted at the FEMP Plant 1 as part of the LSTD project sponsored by the Deactivation and Decommissioning Focus Area (DDFA) of the US DOE`s Office of Science and Technology.

NONE

1999-05-01T23:59:59.000Z

364

Alternative technologies to steam-methane reforming  

SciTech Connect (OSTI)

Steam-methane reforming (SMR) has been the conventional route for hydrogen and carbon monoxide production from natural gas feedstocks. However, several alternative technologies are currently finding favor for an increasing number of applications. The competing technologies include: steam-methane reforming combined with oxygen secondary reforming (SMR/O2R); autothermal reforming (ATR); thermal partial oxidation (POX). Each of these alternative technologies uses oxygen as a feedstock. Accordingly, if low-cost oxygen is available, they can be an attractive alternate to SMR with natural gas feedstocks. These technologies are composed technically and economically. The following conclusions can be drawn: (1) the SMR/O2R, ATR and POX technologies can be attractive if low-cost oxygen is available; (2) for competing technologies, the H{sub 2}/CO product ratio is typically the most important process parameter; (3) for low methane slip, the SMR/O2R, ATR and POX technologies are favored; (4) for full CO{sub 2} recycle, POX is usually better than ATR; (5) relative to POX, the ATR is a nonlicensed technology that avoids third-party involvement; (6) economics of each technology are dependent on the conditions and requirements for each project and must be evaluated on a case-by-case basis.

Tindall, B.M.; Crews, M.A. [Howe-Baker Engineers, Inc., Tyler, TX (United States)

1995-11-01T23:59:59.000Z

365

STeam Injected Piston Engine Troels Hrding Pedersen Bjrn Kjellstrm  

E-Print Network [OSTI]

STIPE STeam Injected Piston Engine Troels H酶rding Pedersen Bj枚rn Kjellstr枚m Thomas Koch Erik Balck stempelmotor med dampindspr酶jtning". English title: "Steam injected piston engine, a feasibility study ......................................................................................12 Stationary engines for decentralised CHP or industrial CHP

366

Steam surface condenser tubes: Watch out for sneaky corrosion  

SciTech Connect (OSTI)

Using case histories, several of the most problematic corrosion mechanisms involving steam surface condenser tubes and the general chemistry behind them are discussed. They include steam-side and water-side corrosion. Examples of stress corrosion cracking and inlet-end erosion-corrosion also are given.

Buecker, B.; Loper, E.

2000-05-01T23:59:59.000Z

367

Steam distribution and energy delivery optimization using wireless sensors  

SciTech Connect (OSTI)

The Extreme Measurement Communications Center at Oak Ridge National Laboratory (ORNL) explores the deployment of a wireless sensor system with a real-time measurement-based energy efficiency optimization framework in the ORNL campus. With particular focus on the 12-mile long steam distribution network in our campus, we propose an integrated system-level approach to optimize the energy delivery within the steam distribution system. We address the goal of achieving significant energy-saving in steam lines by monitoring and acting on leaking steam valves/traps. Our approach leverages an integrated wireless sensor and real-time monitoring capabilities. We make assessments on the real-time status of the distribution system by mounting acoustic sensors on the steam pipes/traps/valves and observe the state measurements of these sensors. Our assessments are based on analysis of the wireless sensor measurements. We describe Fourier-spectrum based algorithms that interpret acoustic vibration sensor data to characterize flows and classify the steam system status. We are able to present the sensor readings, steam flow, steam trap status and the assessed alerts as an interactive overlay within a web-based Google Earth geographic platform that enables decision makers to take remedial action. We believe our demonstration serves as an instantiation of a platform that extends implementation to include newer modalities to manage water flow, sewage and energy consumption.

Olama, Mohammed M [ORNL; Allgood, Glenn O [ORNL; Kuruganti, Phani Teja [ORNL; Sukumar, Sreenivas R [ORNL; Djouadi, Seddik M [ORNL; Lake, Joe E [ORNL

2011-01-01T23:59:59.000Z

368

Community Resilience: Workshops on Private Sector and Property Owner Requirements for Recovery and Restoration from a Diasaster  

SciTech Connect (OSTI)

This report summarizes the results of a proejct sponsored by DTRA to 1) Assess the readiness of private-sector businesses, building owners, and service providers to restore property and recover operations in the aftermath of a wide-area dispersal of anthrax; and 2) Understand what private property owners and businesses "want and need" from federal, state, and local government to support recovery and restoration from such an incident.

Judd, Kathleen S.; Stein, Steven L.; Lesperance, Ann M.

2008-12-22T23:59:59.000Z

369

Issues in the selection of the LMFBR steam cycle  

SciTech Connect (OSTI)

Unlike the light-water reactor, the liquid-metal fast breeder reactor (LMFBR) allows the designer considerable latitude in the selection of the steam cycle. This latitude in selection has been exercised by both foreign and domestic designers, and thus, despite the fact that over 25 LMFBR's have been built or are under construction, a consensus steam cycle has not yet evolved. This paper discusses the LMFBR steam cycles of interest to the LMFBR designer, reviews which of these cycles have been employed to date, discusses steam-cycle selection factors, discusses why a consensus has not evolved, and finally, concludes that the LMFBR steam-cycle selection is primarily one of technical philosophy with several options available.

Buschman, H.W.; McConnell, R.J.

1983-01-01T23:59:59.000Z

370

Issues in the selection of the LMFBR steam cycle  

SciTech Connect (OSTI)

Unlike the light water reactor, the liquid metal fast breeder reactor (LMFBR) allows the designer considerable latitude in the selection of the steam cycle. This latitude in selection has been exercised by both foreign and domestic designers, and thus, despite the fact that over 25 LMFBR's have been built or are under construction, a consensus steam cycle has not yet evolved. This paper discusses the LMFBR steam cycles of interest to the LMFBR designer, reviews which of these cycles have been employed to date, discusses steam-cycle selection factors, discusses why a consensus has not evolved, and finally, concludes that the LMFBR steam-cycle selection is primarily one of technical philosophy with several options available.

Buschchman, H.W.; McConnell, R.J.

1983-08-01T23:59:59.000Z

371

Bullet trains and steam engines: Exogenous attention zips but endogenous attention chugs along  

E-Print Network [OSTI]

Bullet trains and steam engines: Exogenous attention zips but endogenous attention chugs along: Chakravarthi, R., & VanRullen, R. (2011). Bullet trains and steam engines: Exogenous attention zips

VanRullen, Rufin

372

Tools to Boost Steam System Efficiency, Software Tools for Industry, Industrial Technologies Program (ITP) (Fact Sheet)  

SciTech Connect (OSTI)

This fact sheet describes how the Industrial Technologies Program steam software tools can help industrial plants identify steam system improvements to save energy and money.

Not Available

2008-12-01T23:59:59.000Z

373

Steam oxidation and chromia evaporation in ultrasupercritical steam boilers and turbines  

SciTech Connect (OSTI)

The U.S. Department of Energy's goals include power generation from coal at 60% efficiency, which requires steam conditions of up to 760 {sup o}C and 340 atm, so-called ultrasupercritical conditions. Evaporation of protective chromia scales is a primary corrosion mechanism. A methodology to calculate Cr evaporation rates from chromia scales was developed and combined with Cr diffusion calculations within the alloy (with a constant flux of Cr leaving the alloy from evaporation) to predict Cr concentration profiles and to predict the time until breakaway oxidation. At the highest temperatures and pressures, the time until breakaway oxidation was quite short for the turbine blade, and of concern within the steam pipe and the higher temperature portions of the superheater tube. Alloy additions such as Ti may allow for a reduction in evaporation rate with time, mitigating the deleterious effects of chromia evaporation.

Holcomb, G.R. [US DOE, Albany, OR (United States)

2009-07-01T23:59:59.000Z

374

Steam Oxidation and Chromia Evaporation in Ultra-Supercritical Steam Boilers and Turbines  

SciTech Connect (OSTI)

U.S. Department of Energy抯 goals include power generation from coal at 60% efficiency, which requires steam conditions of up to 760 癈 and 340 atm, so-called ultra-supercritical (USC) conditions. Evaporation of protective chromia scales is expected to be a primary corrosion mechanism. A methodology to calculate Cr evaporation rates from chromia scales was developed and combined with Cr diffusion calculations within the alloy (with a constant flux of Cr leaving the alloy from evaporation) to predict Cr concentration profiles and to predict the time until breakaway oxidation. At the highest temperatures and pressures, the time until breakaway oxidation was predicted to be quite short for the turbine blade, and of concern within the steam pipe and the higher temperature portions of the superheater tube. Alloy additions such as Ti may allow for a reduction in evaporation rate with time, mitigating the deleterious effects of chromia evaporation.

Gordon H. Holcomb

2009-01-01T23:59:59.000Z

375

Industrial Steam System Process-Control Schemes: A BestPractices Steam Technical Brief  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensionalthe U.S.Indiana College ProvidesSteam Technical Brief

376

Achieve smokeless flaring -- Air or steam assist?  

SciTech Connect (OSTI)

Because of the technological advances made during the past several years, flare system design has become more important with respect to the economics of plant operation. There are many options available to the engineer during the initial design phase of a flare system for a chemical process industries (CPI) plant. An earlier CEP article covered the basics of flare design and how to choose and size the right equipment, such as stack height and diameter, tip design, pilots and pilots flame detectors, seals, and so on. One of the most important factors is how to achieve smokeless operation, which is accomplished by either steam-assisted or air-assisted elevated flare stack assemblies. This article compares the two approaches and outlines the advantages and disadvantages of each with respect to economics, practicality, and operability. Table 1 summarizes the data for a typical plant in the U.S. Gulf Coast area that will be used as the basis for comparing costs.

Chaudhuri, M.; Diefenderfer, J.J.

1995-06-01T23:59:59.000Z

377

Steam turbine path evaluation during maintenance  

SciTech Connect (OSTI)

The deterioration of a turbine (Steam & Gas) flow path affects the efficiency of the turbine. The most critical factors which affect the efficiency of turbines are: wearing out of the trailing edges of the blades by solid particle erosion, deposits, material loss due to corrosion (also sand blast) which increases the flow area, increases in blade surface roughness, etc. Wearing out of the seals caused by shaft vibrations or rapid start-up leads to significant leakage losses. Some of these effects can be estimated with some precision during operation of the turbine, but an exact evaluation can be carried out during a maintenance applying a special fluid flow analysis program. Such a program has been developed and then adapted to achieve this goal. During maintenance the complete geometry of the steam path is measured (blades lengths, widths, angles, clearances, etc.) in the condition encountered before any corrections. Then the similar measurement is undertaken after, for example, clearance corrections, blade replacements, cleaning of the blades, etc. Using the program first of all the design data is calculated. Then the actual data is fed into the program and compared to the design data. Thus the effect of the blade surface roughness, increased seal clearances, flow area increase, solid particle damage to the trailing edge and so on for each particular stage is calculated. The effect is expressed in [kW] as a deviation from the design points. This data can be helpful during online evaluation of the turbine performance. This evaluation helps the management of the plant in undertaking the correct decision concerning the date of the next major maintenance and replacement part procurement. Many turbines in the Mexican utility have been evaluated in such a manner. Some examples are presented.

Kubiak, J.; Angel, F. del; Carnero, A.; Campos, A. [Instituto de Investigaciones Electricas, Temixo, Morelos (Mexico)] [and others

1996-07-01T23:59:59.000Z

378

Method for cutting steam heat losses during cyclic steam injection of wells. Final report  

SciTech Connect (OSTI)

Heavy Oil is abundant in California. It is a very viscous fluid, which must be thinned in order to flow from wells at economical rates. The best method of oil viscosity reduction is by cyclic steam injection into the oil-containing rock formations. Making steam in conventional generators fueled with Natural Gas is, however, a costly process. The main objective of this Project is to reduce the cost of the required steam, per Barrel of Oil produced. This is made possible by a combination of Patented new technologies with several known methods. The best known method for increasing the production rate from oil wells is to use horizontal drainholes, which provide a much greater flow area from the oil zone into the well. A recent statistic based on 344 horizontal wells in 21 Canadian Oil fields containing Heavy Oil shows that these are, on the average six times more prolific than vertical wells. The cost of horizontal wells, however, is generally two to three times that of a vertical well, in the same field, so our second goal is to reduce the net cost of horizontal wells by connecting two of them to the same vertical casing, well head and pumping system. With such a well configuration, it is possible to get two horizontal wells for the price of about one and a half times the price of a single vertical well.

Gondouin, M.

1995-12-01T23:59:59.000Z

379

Simulation of a main steam line break with steam generator tube rupture using trace  

SciTech Connect (OSTI)

A simulation of the OECD/NEA ROSA-2 Project Test 5 was made with the thermal-hydraulic code TRACE5. Test 5 performed in the Large Scale Test Facility (LSTF) reproduced a Main Steam Line Break (MSLB) with a Steam Generator Tube Rupture (SGTR) in a Pressurized Water Reactor (PWR). The result of these simultaneous breaks is a depressurization in the secondary and primary system in loop B because both systems are connected through the SGTR. Good approximation was obtained between TRACE5 results and experimental data. TRACE5 reproduces qualitatively the phenomena that occur in this transient: primary pressure falls after the break, stagnation of the pressure after the opening of the relief valve of the intact steam generator, the pressure falls after the two openings of the PORV and the recovery of the liquid level in the pressurizer after each closure of the PORV. Furthermore, a sensitivity analysis has been performed to know the effect of varying the High Pressure Injection (HPI) flow rate in both loops on the system pressures evolution. (authors)

Gallardo, S.; Querol, A.; Verdu, G. [Departamento de Ingenieria Quimica Y Nuclear, Universitat Politecnica de Valencia, Camino de Vera s/n, 46022, Valencia (Spain)

2012-07-01T23:59:59.000Z

380

Method and apparatus for improving the performance of a steam driven power system by steam mixing  

DOE Patents [OSTI]

A method and apparatus for improving the efficiency and performance of a steam driven power plant wherein addition of steam handling equipment to an existing plant results in a surprising increase in plant performance. For Example, a gas turbine electrical generation system with heat recovery boiler may be installed along with a micro-jet high pressure and a low pressure mixer superheater. Depending upon plant characteristics, the existing moisture separator reheater (MSR) can be either augmented or done away with. The instant invention enables a reduction in T.sub.hot without a derating of the reactor unit, and improves efficiency of the plant's electrical conversion cycle. Coupled with this advantage is a possible extension of the plant's fuel cycle length due to an increased electrical conversion efficiency. The reduction in T.sub.hot further allows for a surprising extension of steam generator life. An additional advantage is the reduction in erosion/corrosion of secondary system components including turbine blades and diaphragms. The gas turbine generator used in the instant invention can also replace or augment existing peak or emergency power needs. Another benefit of the instant invention is the extension of plant life and the reduction of downtime due to refueling.

Tsiklauri, Georgi V. (Richland, WA); Durst, Bruce M. (Kennewick, WA); Prichard, Andrew W. (Richland, WA); Reid, Bruce D. (Pasco, WA); Burritt, James (Virginia Beach, VA)

1998-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Field measurement of solid particle erosion in utility steam turbines  

SciTech Connect (OSTI)

For the first time, extensive field testing has characterized solid particle erosion (SPE) in terms of size and frequency. This is particularly important because SPE damage to large steam turbine components can degrade plant efficiency, increasing operating costs by up to $3 million/yr per unit for a total of $150 million nationwide. The objective was to characterize under various operating conditions the level and distribution of magnetite particles in turbine steam and the resulting SPE. The project team developed a field test program to characterize the solid particles in turbine steam and measure the erosion resistance of various coatings. At Dayton Power Light, a 600-MW turbine generator unit with a coal-fired once-through supercritical boiler was fitted with two steam sampling systems, the first for isokinetic sampling and the second for erosion evaluation. The team took roughly 300 isokinetic steam samples from the main steam line during both startup and full-load operation. They condensed and filtered each steam sample, then determined the level and distribution of magnetite particles.

Duncan, D.; Vohr, J.H.; Shalvoy, R.S. (General Electric Co., Schenectady, NY (United States). Turbine Technology Dept.)

1992-01-01T23:59:59.000Z

382

Chemical tailoring of steam to remediate underground mixed waste contaminents  

DOE Patents [OSTI]

A method to simultaneously remediate mixed-waste underground contamination, such as organic liquids, metals, and radionuclides involves chemical tailoring of steam for underground injection. Gases or chemicals are injected into a high pressure steam flow being injected via one or more injection wells to contaminated soil located beyond a depth where excavation is possible. The injection of the steam with gases or chemicals mobilizes contaminants, such as metals and organics, as the steam pushes the waste through the ground toward an extraction well having subatmospheric pressure (vacuum). The steam and mobilized contaminants are drawn in a substantially horizontal direction to the extraction well and withdrawn to a treatment point above ground. The heat and boiling action of the front of the steam flow enhance the mobilizing effects of the chemical or gas additives. The method may also be utilized for immobilization of metals by using an additive in the steam which causes precipitation of the metals into clusters large enough to limit their future migration, while removing any organic contaminants.

Aines, Roger D. (Livermore, CA); Udell, Kent S. (Berkeley, CA); Bruton, Carol J. (Livermore, CA); Carrigan, Charles R. (Tracy, CA)

1999-01-01T23:59:59.000Z

383

U.S. Nominal Cost per Foot of Dry Wells Drilled (Dollars per Foot)  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecemberSteamYearTexas--StateWinterYear Jan Feb Mar Apr MayFeet)OilDry Wells

384

Texas - RRC District 10 Dry Natural Gas Expected Future Production (Billion  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecemberSteamYear Jan FebThousandProcessed (Million(MillionCubic Feet) Dry

385

Texas - RRC District 7B Dry Natural Gas Expected Future Production (Billion  

Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelines AboutDecemberSteamYear Jan FebThousandProcessedLeaseSeparation,Cubic Feet) Dry

386

The economic effects of elevated and depressed freeways on adjacent property owners  

E-Print Network [OSTI]

ABSTRACT The Economic EfFects of Elevated and Depressed Freeways on The Adjacent Property Owners. (May 1995) Floyd David Sentry, B. S. , Texas AkM University Chair of Advisory Committee: Dr. Daniel B. Fambro An econonuc assessment of a comnunity... 322, 095 283, 680 283, 680 260, 040 3, 327, 330 $5, 005, 770 Net Effect of Highway on Property Values $4, 275 139, 635 185, 310 262, 145 254, 800 271, 680 257, 840 3, 327, 330 $4, 703, 095 23 The resale of homes at all levels showed...

Scurry, Floyd David

1995-01-01T23:59:59.000Z

387

Newport News Business Owner Earns Award From Jefferson Lab | Jefferson Lab  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the Contributions andDataNationalNewport News Business Owner Earns Award From Jefferson

388

Extending the useful life of industrial steam turbines  

SciTech Connect (OSTI)

This paper reports that technology, uprating, and steam-path degradation reversal can extend the life and boost the efficiency of aging turbines. With the advent of modern machine tool technology, plus extensive R and D efforts, designers could apply improved bucket designs like the laminar flow design. Today's technology is represented by the Schlict design, which minimizes flow separations and boundary layer losses. Schlict buckets can be retrofitted in most designs as long as the diaphragm is also replaced. Adoption of steam-path design advance developed for new units and degradation reversal are the two areas of greatest opportunity in efficiency improvement of aging steam turbine-generators.

O'Connor, M.F.; Timmerman, D.C. (GE Power Generation, Schenectady, NY (US))

1990-05-01T23:59:59.000Z

389

Production and mitigation of acid chlorides in geothermal steam  

SciTech Connect (OSTI)

Measurements of the equilibrium distribution of relatively nonvolatile solutes between aqueous liquid and vapor phases have been made at temperatures to 350{degrees}C for HCl(aq) and chloride salts. These data are directly applicable to problems of corrosive-steam production in geothermal steam systems. Compositions of high-temperature brines which could produce steam having given concentrations of chlorides may be estimated at various boiling temperatures. Effects of mitigation methods (e.g., desuperheating) can be calculated based on liquid-vapor equilibrium constants and solute mass balances under vapor-saturation conditions.

Simonson, J.M.; Palmer, D.A.

1995-06-01T23:59:59.000Z

390

Compatibility of selected ceramics with steam-methane reformer environments  

SciTech Connect (OSTI)

Conventional steam reforming of methane to synthesis gas (CO and H{sub 2}) hasa conversion efficiency of about 85%. Replacement of metal tubes in the reformer with ceramic tubes offers the potential for operation at temperatures high enough to increase the efficiency to 98-99%. However, the two candidate ceramic materials being given strongest consideration, sintered alpha Si carbide and Si carbide particulate-strengthened alumina, have been shown to react with components of the reformer environment. Extent of degradation as a function of steam partial pressure and exposure time has been studied, and results suggest limits under which these structural ceramics can be used in advanced steam-methane reformers.

Keiser, J.R.; Howell, M. [Oak Ridge National Lab., TN (United States); Williams, J.J.; Rosenberg, R.A. [Stone and Webster Engineering Corp., Boston, MA (United States)

1996-04-01T23:59:59.000Z

391

DYNAMIC SIMULATION OF MONO-TUBE CAVITY RECEIVERS FOR DIRECT STEAM GENERATION  

E-Print Network [OSTI]

that includes a 4 cylinder steam engine coupled with a 3 phase generator. This paper describes ongoing research cavity receiver [2] mounted to the 500 m2 dish receiver supports, a modified steam engine coupled transports superheated steam via rotary joints to the ground and then to a 4 cylinder steam engine

392

"Hot Water" in Lassen Volcanic National Park--Fumaroles, Steaming Ground, and Boiling Mudpots  

E-Print Network [OSTI]

"Hot Water" in Lassen Volcanic National Park-- Fumaroles, Steaming Ground, and Boiling Mudpots U, ydrothermal (hot water) and steaming ground. These features are re- lated to active volcanism, the largest fumarole (steam and volcanic-gas vent) in the park. The temperature of the high-velocity steam

Torgersen, Christian

393

1. Introduction The efficiency of steam turbines can be improved by in-  

E-Print Network [OSTI]

1. Introduction The efficiency of steam turbines can be improved by in- creasing the maximum-efficiency power plant. 2. Turbines, Steam, Efficiency and Power Plant A power plant has a steam generator which the operating pressure is below about 22 MPa, in which case the steam is separated and passed on to the turbine

Cambridge, University of

394

Solar PV Project Financing: Regulatory and Legislative Challenges for Third-Party PPA System Owners  

SciTech Connect (OSTI)

Residential and commercial end users of electricity who want to generate electricity using on-site solar photovoltaic (PV) systems face challenging initial and O&M costs. The third-party ownership power purchase agreement (PPA) finance model addresses these and other challenges. It allows developers to build and own PV systems on customers? properties and sell power back to customers. However, third-party electricity sales commonly face five regulatory challenges. The first three challenges involve legislative or regulatory definitions of electric utilities, power generation equipment, and providers of electric services. These definitions may compel third-party owners of solar PV systems to comply with regulations that may be cost prohibitive. Third-party owners face an additional challenge if they may not net meter, a practice that provides significant financial incentive to owning solar PV systems. Finally, municipalities and cooperatives worry about the regulatory implications of allowing an entity to sell electricity within their service territories. This paper summarizes these challenges, when they occur, and how they have been addressed in five states. This paper also presents alternative to the third-party ownership PPA finance model, including solar leases, contractual intermediaries, standardized contract language, federal investment tax credits, clean renewable energy bonds, and waived monopoly powers.

Kollins, K.; Speer, B.; Cory, K.

2009-11-01T23:59:59.000Z

395

Rotating diffuser for pressure recovery in a steam cooling circuit of a gas turbine  

DOE Patents [OSTI]

The buckets of a gas turbine are steam-cooled via a bore tube assembly having concentric supply and spent cooling steam return passages rotating with the rotor. A diffuser is provided in the return passage to reduce the pressure drop. In a combined cycle system, the spent return cooling steam with reduced pressure drop is combined with reheat steam from a heat recovery steam generator for flow to the intermediate pressure turbine. The exhaust steam from the high pressure turbine of the combined cycle unit supplies cooling steam to the supply conduit of the gas turbine.

Eldrid, Sacheverel Q. (Saratoga Springs, NY); Salamah, Samir A. (Niskayuna, NY); DeStefano, Thomas Daniel (Ballston Lake, NY)

2002-01-01T23:59:59.000Z

396

Fluidized Bed Steam Reforming of Hanford LAW Using THORsm Mineralizing Technology  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) documented, in 2002, a plan for accelerating cleanup of the Hanford Site, located in southeastern Washington State, by at least 35 years. A key element of the plan was acceleration of the tank waste program and completion of ''tank waste treatment by 2028 by increasing the capacity of the planned Waste Treatment Plant (WTP) and using supplemental technologies for waste treatment and immobilization.'' The plan identified steam reforming technology as a candidate for supplemental treatment of as much as 70% of the low-activity waste (LAW). Mineralizing steam reforming technology, offered by THOR Treatment Technologies, LLC would produce a denitrated, granular mineral waste form using a high-temperature fluidized bed process. A pilot scale demonstration of the technology was completed in a 15-cm-diameter reactor vessel. The pilot scale facility was equipped with a highly efficient cyclone separator and heated sintered metal filters for particulate removal, a thermal oxidizer for reduced gas species and NOx destruction, and a packed activated carbon bed for residual volatile species capture. The pilot scale equipment is owned by the DOE, but located at the Science and Technology Applications Research (STAR) Center in Idaho Falls, ID. Pilot scale testing was performed August 25, 2004. Flowsheet chemistry and operational parameters were defined through a collaborative effort involving Idaho National Engineering and Environmental Laboratory, Savannah River National Laboratory (SRNL), and THOR Treatment Technologies personnel. Science Application International Corporation, owners of the STAR Center, personnel performed actual pilot scale operation. The pilot scale test achieved a total of 68.7 hrs of cumulative/continuous processing operation before termination in response to a bed de-fluidization condition. 178 kg of LAW surrogate were processed that resulted in 148 kg of solid product, a mass reduction of about 17%. The process achieved essentially complete bed turnover within approximately 40 hours. Samples of mineralized solid product materials were analyzed for chemical/physical properties. SRNL will report separately the results of product performance testing that were accomplished.

Olson, Arlin L.; Nicholas R Soelberg; Douglas W. Marshall; Gary L. Anderson

2004-11-01T23:59:59.000Z

397

Steam turbine restart temperature maintenance system and method  

SciTech Connect (OSTI)

A restart temperature maintenance system is described for a steam turbine system; the steam turbine system comprising a steam turbine, the turbine including a rotation shaft, an outer metal shell means. The restart temperature maintenance system consists of: (a) fastener means affixed to the outer surface of the shell means at predetermined positions; (b) air gap spacer means affixed to the outer surface of the shell means, the air gap spacer means substantially covering the shell means; (c) a plurality of electric heating blanket means of predetermined size and shape positioned in insulative relationship over the air gap spacer means and the heating blanket means maintained in predetermined position by the fastener means; (d) heat sensor means affixed to the outer metal shell means of the steam turbine in predetermined position; (e) power supply means for supplying power to the heating blanket means; (f) heat sensor monitor and controller means connected in circuit between the power supply means and the heat sensor means.

McClelland, T.R.

1986-04-29T23:59:59.000Z

398

Building America Expert Meeting: Multifamily Hydronic and Steam...  

Broader source: Energy.gov (indexed) [DOE]

was cost-effective controls and distribution retrofit options for hot water and steam space heating systems in multi-family buildings with the goals of reducing energy waste and...

399

Steam System Management Program Yields Fuel Savings for Refinery  

E-Print Network [OSTI]

The Phillips refinery at Borger, Texas, determined the need to develop a utility monitoring system. Shortly after this commitment was made, the refinery was introduced to a flowsheet modeling program that could be used to model and optimize steam...

Gaines, L. D.; Hagan, K. J.

1983-01-01T23:59:59.000Z

400

Clock mechanisms and their effects, leads into steam engine  

E-Print Network [OSTI]

In a clock-maker抯 shop, Simon Schaffer explains the great precision needed to make clocks, and the development of standardized parts. The feed-back mechanisms or governors are absolutely essential in the first stationary steam engines....

Dugan, David

2004-08-17T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

An Analysis of Steam Process Heater Condensate Drainage Options  

E-Print Network [OSTI]

The production and reliability performance of Steam Process Heaters can be significantly affected by the condensate drainage design that is employed. There are currently a variety of drainage options which can be confusing to a system designer who...

Risko, J. R.

402

Optimizing Steam and Condensate System: A Case Study  

E-Print Network [OSTI]

Optimization of Steam & Condensate systems in any process plant results in substantial reduction in purchased energy cost. During periods of natural gas price hikes, this would benefit the plant in controlling their fuel budget significantly...

Venkatesan, V. V.; Merritt, B.; Tully, R. C.

403

Steam generator operating experience: Update for 1984-1986  

SciTech Connect (OSTI)

This report summarizes operational events and degradation mechanisms affecting pressurized water reactor steam generator integrity, provides updated inspection results reported in 1984, 1985, and 1986, and highlights both prevalent problem areas and advances in improved equipment test practices, preventive measures, repair techniques, and replacement procedures. It describes equipment design features of the three major suppliers and discusses 68 plants in detail. Steam generator degradation mechanisms include intergranular stress corrosion cracking, primary water stress corrosion cracking, pitting, intergranular attack, and vibration wear that effects tube integrity and causes leakage. Plugging, sleeving heat treatment, peening, chemical cleaning, and steam generator replacements are described and regulatory instruments and inspection guidelines for nondestructive evaluations and girth weld cracking are discusses. The report concludes that although degradation mechanisms are generally understood, the elimination of unscheduled plant shutdowns and costly repairs resulting from leaking tubes has not been achieved. Highlights of steam generator research and unresolved safety issues are discussed. 21 refs., 8 tabs.

Frank, L.; Stokley, J.

1988-06-01T23:59:59.000Z

404

Use Low-Grade Waste Steam to Power Absorption Chillers  

SciTech Connect (OSTI)

This revised ITP tip sheet on waste steam to power absorption chillers provides how-to advice for improving the system using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

405

Hanford Low Activity Waste (LAW) Fluidized Bed Steam Reformer...  

Office of Environmental Management (EM)

Low Activity Waste (LAW) Fluidized Bed Steam Reformer (FBSR) Na-Al-Si (NAS) Waste Form Qualification C.M. Jantzen and E.M. Pierce November 18, 2010 2 Participating Organizations 3...

406

Thermohydraulic analysis of U-tube steam generators  

E-Print Network [OSTI]

Recent trends in plant safety analysis reveal a need for benchmark analytical representations of the steam generators to aid in the improvement of system codes and of fast codes for operator assistance. A model for such ...

da Silva, Hugo Cardoso

1984-01-01T23:59:59.000Z

407

C++ Implementation of IAPWS Water/Steam Properties  

SciTech Connect (OSTI)

For the calculations of water-involved systems, such as safety analysis of light water reactors, it is essential to provide accurate water properties. The International Association for the Properties of Water and Steam is an international non-profit association of national organizations concerned with the properties of water and steam. It provides internationally accepted formulations of water/steam properties for scientific and industrial applications. The purpose of this work is to provide a stand-alone software package in C++ programming language to provide accurate and efficient water/steam properties evaluation, based on the latest IAPWS releases. The discussion on related IAPWS releases, code implementations and verifications are provided in details.

Ling Zou; Haihua Zhao; Hongbin Zhang; Qiyue Lu

2014-02-01T23:59:59.000Z

408

Steam Turbines for Critical Applications and Emergency or Standby Drives  

E-Print Network [OSTI]

Steam turbines are frequently preferred over electric motors where operational continuity is important. This often imposes extreme premiums in operating cost. The parameters affecting relative economics are explored and a range of alternatives...

Waterland, A. F.

409

The Economics of Back-Pressure Steam Turbines  

E-Print Network [OSTI]

Recently, back-pressure steam turbines have become the focal point in many cogeneration applications. This is a result of the savings in operating costs associated with the generation of electrical or mechanical power coincident with the economical...

Wagner, J. R.; Choroszylow, E.

1982-01-01T23:59:59.000Z

410

Cycle Configurations for a PBMR Steam and Electricity Production Plant  

SciTech Connect (OSTI)

The Pebble Bed Modular Reactor (PBMR) is an advanced helium-cooled, graphite moderated High Temperature Gas-cooled Reactor (HTGR) that is capable of multiple missions. The petrochemical industry requires the use of high temperature steam and electricity for their processes. Currently coal or natural gas is utilised for the generation of high temperature steam and electricity, which under-utilises natural resources and in the process emits CO{sub 2} into the atmosphere. This paper provides an overview of the PBMR product development path and discusses how steam production forms part of the future possibilities of the PBMR technology. Suitable cycle configurations for both process steam and electricity generation as required by petrochemical plants are discussed. (authors)

Matzner, Dieter; Kriel, Willem; Correia, Michael; Greyvenstein, Renee [PBMR - Pty - Ltd, Lake Buena Vista Building, 1267 Gordon Hood Avenue, Centurion, PO Box 9396, Centurion 0046 (South Africa)

2006-07-01T23:59:59.000Z

411

Halophilic Archaea determined from geothermal steam vent aerosols  

E-Print Network [OSTI]

the leaching of salts and minerals through the highly porous volcanic rock, creating a chemically complex differentials to condense steam into gamma-irradiated polypropylene centrifuge tubes (Fig. 1B), collected up

Kelley, Scott

412

Steam bubble collapse, water hammer and piping network response  

E-Print Network [OSTI]

Work on steam bubble collapse, water hammer and piping network response was carried out in two closely related but distinct sections. Volume I of ,,is report details the experiments and analyses carried out in conjunction ...

Gruel, R.

413

Alloys for advanced steam turbines--Oxidation behavior  

SciTech Connect (OSTI)

Advanced or ultra supercritical (USC) steam power plants offer the promise of higher efficiencies and lower emissions. Current goals of the U.S. Department of Energy (DOE) include power generation from coal at 60% efficiency, which would require steam temperatures of up to 760癈. Current research on the oxidation of candidate materials for advanced steam turbines is presented with a focus on a methodology for estimating chromium evaporation rates from protective chromia scales. The high velocities and pressures of advanced steam turbines lead to evaporation predictions as high as 5 10-8 kg m-2s-1 of CrO2(OH)2(g) at 760癈 and 34.5 MPa. This is equivalent to 0.077 mm per year of solid Cr loss.

Holcomb, G.R.

2007-10-01T23:59:59.000Z

414

The Use of Electrochemical Techniques to Characterize Wet Steam Environments  

SciTech Connect (OSTI)

The composition of a steam phase in equilibrium with a water phase at high temperature is remarkably affected by the varying capabilities of the water phase constituents to partition into the steam. Ionic impurities (sodium, chloride, sulfate, etc.) tend to remain in the water phase, while weakly ionic or gaseous species (oxygen) partition into the steam. Analysis of the water phase can provide misleading results concerning the steam phase composition or environment. This paper describes efforts that were made to use novel electrochemical probes and sampling techniques to directly characterize a wet steam phase environment in equilibrium with high temperature water. Probes were designed to make electrochemical measurements in the thin film of water existing on exposed surfaces in steam over a water phase. Some of these probes were referenced against a conventional high temperature electrode located in the water phase. Others used two different materials (typically tungsten and platinum) to make measurements without a true reference electrode. The novel probes were also deployed in a steam space removed from the water phase. It was necessary to construct a reservoir and an external, air-cooled condenser to automatically keep the reservoir full of condensed steam. Conventional reference and working electrodes were placed in the water phase of the reservoir and the novel probes protruded into the vapor space above it. Finally, water phase probes (both reference and working electrodes) were added to the hot condensed steam in the external condenser. Since the condensing action collapsed the volatiles back into the water phase, these electrodes proved to be extremely sensitive at detecting oxygen, which is one of the species of highest concern in high temperature power systems. Although the novel steam phase probes provided encouraging initial results, the tendency for tungsten to completely corrode away in the steam phase limited their usefulness. However, the conventional water phase electrodes, installed both in the reservoir and in the external condensing coil, provided useful data showing the adverse impact of oxygen and carbon dioxide on the REDOX potential and high temperature pH, respectively.

Bruce W. Bussert; John A. Crowley; Kenneth J. Kimball; Brian J. Lashway

2003-04-30T23:59:59.000Z

415

Emissions control through dry scrubbing  

SciTech Connect (OSTI)

Concern with operating problems, and the desire for system simplicity, has resulted in the development of dry scrubbing systems for flue gas cleanup, and their acceptance by industry as an alternate to the conventional wet scrubbers. These dry scrubbing systems incorporate two commonly used pieces of equipment; spray dryers, which have been used for many years to manufacture everything from detergents to powdered milk, and a particulates removal device (either a fabric filter or an electrostatic precipitator). The first application of this technology to removal of sulfur oxides from high sulfur coal combustion gases occurred when Argonne National Laboratory installed a system in 1981 as the control device on its main coal-fired boiler. To date, this type of pollution control system has shown itself capable of meeting state emission standards and, in a special test run, of removing over 90% of the sulfur oxides produced from combustion of a coal with over 4% sulfur.

Farber, P.S.

1986-01-01T23:59:59.000Z

416

Estimate steam-turbine losses to justify maintenance funds  

SciTech Connect (OSTI)

A procedure to estimate steam-turbine losses is described. The estimates are based on analytical calculations and field inspections of turbines with known performance deterioration resulting from their environment, not their construction. They are, therefore, applicable to many types of steam turbines. Common causes of deterioration are the following: solid particle erosion, deposits, increased clearances, and peening or damage from foreign material. Performance losses due to these factors are analyzed. An example of application is given.

Not Available

1982-05-01T23:59:59.000Z

417

Steam Partnerships: Case Study of Improved Energy Efficiency  

E-Print Network [OSTI]

Steam Partnerships: Case Study of Improved Energy Efficiency Michael V. Calogero, P.E., CEM Robert E. Hess Novi Leigh Director, Northeast Operations Sr. Energy Systems Engineer Energy Systems Engineer Armstrong Service, Inc ABSTRACT Effective.... 1998-2001 operating data from client's laundry processing facility. 3. Turner, Wayne C., Energy Management Handbook, 2 nd edition, 1993. 4. Armstrong International, Inc., Steam Conservation Guidelines for Condensate Drainage, Handbook N-1 01, 1997...

Calogero, M. V.; Hess, R. E.; Leigh, N.

418

Method for increasing steam decomposition in a coal gasification process  

DOE Patents [OSTI]

The gasification of coal in the presence of steam and oxygen is significantly enhanced by introducing a thermochemical water-splitting agent such as sulfuric acid, into the gasifier for decomposing the steam to provide additional oxygen and hydrogen usable in the gasification process for the combustion of the coal and enrichment of the gaseous gasification products. The addition of the water-splitting agent into the gasifier also allows for the operation of the reactor at a lower temperature.

Wilson, Marvin W. (Fairview, WV)

1988-01-01T23:59:59.000Z

419

Turbine Steam Path Audits for Improved Performance and Profitability  

E-Print Network [OSTI]

TURBINE STEAM PATH AUDITS FOR IMPROVED PERFORMANCE AND PROFITABILITY PAUL E. BABSON, DIRECTOR, BUSINESS DEVELOPMENT, ENCOTECH, INC., SCHENECTADY, NEW YORK ABSTRACT This paper describes the use and value of conducting steam path audits... in turbines. Critical measurements and observations made during overhaul identify and quantify the effects of component degradations upon turbine performance as compared to design conditions. The information generated permits performance oriented repair...

Babson, P. E.

420

Why Condensing Steam Turbines are More Efficient than Gas Turbines  

E-Print Network [OSTI]

WHY CONDENSING STEAM TURBINES ARE MORE EFFICIENT THAN GAS TURBINES KENNETH E. NELSON Associate Energy Consultant Dow Chemical U.S.A. Plaquemine. Louisiana INTRODUCTION AND ABSTRACT Consider the following questions: 1. Which is bigger... statement. however, is relevant to value. GAS TURBINE CYCLE Figure :> shows the enthalpy analysis for a gas turbine cycle employing a heat recovery unit for steam generation. Air enters the compressor where it's boosted to about 190 psi and mixed...

Nelson, K. E.

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Method for increasing steam decomposition in a coal gasification process  

DOE Patents [OSTI]

The gasification of coal in the presence of steam and oxygen is significantly enhanced by introducing a thermochemical water- splitting agent such as sulfuric acid, into the gasifier for decomposing the steam to provide additional oxygen and hydrogen usable in the gasification process for the combustion of the coal and enrichment of the gaseous gasification products. The addition of the water-splitting agent into the gasifier also allows for the operation of the reactor at a lower temperature.

Wilson, M.W.

1987-03-23T23:59:59.000Z

422

Downhole steam generator having a downhole oxidant compressor  

DOE Patents [OSTI]

Am improved apparatus is described for the downhole injection of steam into boreholes, for tertiary oil recovery. It includes an oxidant supply, a fuel supply, an igniter, a water supply, an oxidant compressor, and a combustor assembly. The apparatus is designed for efficiency, preheating of the water, and cooling of the combustion chamber walls. The steam outlet to the borehole is provided with pressure-responsive doors for closing the outlet in response to flameout. (DLC)

Fox, R.L.

1981-01-07T23:59:59.000Z

423

Textile Drying Via Wood Gasification  

E-Print Network [OSTI]

TEXTILE DRYING VIA WOOD GASIFICATION Thomas F. ;McGowan, Anthony D. Jape Georgia Institute of Technology Atlanta, Georgia ABSTRACT This project was carried out to investigate the possibility of using wood gas as a direct replacement... for dryers. In addition to the experimental program described above, the DOE grant covered two other major areas. A survey of the textile industry was made to assess the market for gasification equip ment. The major findings were that a large amount...

McGowan, T. F.; Jape, A. D.

1983-01-01T23:59:59.000Z

424

A theoretical and numerical investigation of turbulent steam jets in BWR steam blowdown.  

SciTech Connect (OSTI)

The preliminary results of PHOENICS and RELAP5 show that the current numerical models are adequate in predicting steam flow and stratification patterns in the upper Drywell of a BWR containment subsequent to a blow-down event. However, additional modeling is required in order to study detailed local phenomena such as condensation with non-condensables, natural convection, and stratification effects. Analytically, the intermittence modified similarity solutions show great promise. Once {gamma} is accounted for, the jet's turbulent shear stress can be determined with excellent accuracy.

NguyenLe, Q.

1998-06-26T23:59:59.000Z

425

Industrial Steam System Heat-Transfer SolutionsL: A BestPractices Steam Technical Brief  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensionalthe U.S.Indiana College ProvidesSteam Technical Brief Industrial

426

Closed circuit steam cooled turbine shroud and method for steam cooling turbine shroud  

DOE Patents [OSTI]

A turbine shroud cooling cavity is partitioned to define a plurality of cooling chambers for sequentially receiving cooling steam and impingement cooling of the radially inner wall of the shoud. An impingement baffle is provided in each cooling chamber for receiving the cooling media from a cooling media inlet in the case of the first chamber or from the immediately upstream chamber in the case of the second through fourth chambers and includes a plurality of impingement holes for effecting the impingement cooling of the shroud inner wall.

Burdgick, Steven Sebastian (Schenectady, NY); Sexton, Brendan Francis (Simpsonville, SC); Kellock, Iain Robertson (Simpsonville, SC)

2002-01-01T23:59:59.000Z

427

The Ringhals 2 steam generator replacement  

SciTech Connect (OSTI)

Righals 2, located on the west coast of Sweden and operated by Vattenfall (Swedish State Power), is a Westinghouse 800-MW three-loop pressurized water reactor that started commercial operation in 1975. In 1983, a task force was assigned to make a study of the steam generator (SG) tube corrosion problems, mainly stress corrosion cracking in the tubesheet area, which caused between two and three unscheduled outages each year. The task force study concluded that replacement was clearly the best of the three alternatives considered. Late in 1984, a decision was made to replace the SG in the summer of 1989. It was also decided to take advantage of existing margins in the plant by increasing the heat transfer area of the new SG. A power increase of 9% would then be possible by fairly moderate modifications of the turbine plant. The SG replacement project was on time, below budget, and much below dose budget. As a consequence of the 9% uprating, the cost of the SG replacement will be recovered after 3 to 4 yr.

Looft, H.

1990-06-01T23:59:59.000Z

428

TWR Bench-Scale Steam Reforming Demonstration  

SciTech Connect (OSTI)

The Idaho Nuclear Technology and Engineering Center (INTEC) was home to nuclear fuel reprocessing activities for decades at the Idaho National Engineering and Environmental Laboratory. As a result of the reprocessing activities, INTEC has accumulated approximately one million gallons of acidic, radioactive, sodium-bearing waste (SBW). The purpose of this demonstration was to investigate a reforming technology, offered by ThermoChem Waste Remediation, LLC, (TWR) for treatment of SBW into a ''road ready'' waste form that would meet the waste acceptance criteria for the Waste Isolation Pilot Plant (WIPP). TWR is the licensee of Manufacturing Technology Conservation International (MTCI) steam-reforming technology in the field of radioactive waste treatment. A non-radioactive simulated SBW was used based on the known composition of waste tank WM-180 at INTEC. Rhenium was included as a non-radioactive surrogate for technetium. Data was collected to determine the nature and characteristics of the product, the operability of the technology, the composition of the off-gases, and the fate of key radionuclides (cesium and technetium) and volatile mercury compounds. The product contained a low fraction of elemental carbon residues in the cyclone and filter vessel catches. Mercury was quantitatively stripped from the product but cesium, rhenium (Tc surrogate), and the heavy metals were retained. Nitrate residues were about 400 ppm in the product and NOx destruction exceeded 86%. The demonstration was successful.

Marshall, D.W.; Soelberg, N.R.

2003-05-21T23:59:59.000Z

429

TWR Bench-Scale Steam Reforming Demonstration  

SciTech Connect (OSTI)

The Idaho Nuclear Technology and Engineering Center (INTEC) was home to nuclear fuel reprocessing activities for decades at the Idaho National Engineering and Environmental Laboratory. As a result of the reprocessing activities, INTEC has accumulated approximately one million gallons of acidic, radioactive, sodium-bearing waste (SBW). The purpose of this demonstration was to investigate a reforming technology, offered by ThermoChem Waste Remediation, LLC, (TWR) for treatment of SBW into a "road ready" waste form that would meet the waste acceptance criteria for the Waste Isolation Pilot Plant (WIPP). TWR is the licensee of Manufacturing Technology Conservation International (MTCI) steam-reforming technology in the field of radioactive waste treatment. A non-radioactive simulated SBW was used based on the known composition of waste tank WM-180 at INTEC. Rhenium was included as a non-radioactive surrogate for technetium. Data was collected to determine the nature and characteristics of the product, the operability of the technology, the composition of the off-gases, and the fate of key radionuclides (cesium and technetium) and volatile mercury compounds. The product contained a low fraction of elemental carbon residues in the cyclone and filter vessel catches. Mercury was quantitatively stripped from the product but cesium, rhenium (Tc surrogate), and the heavy metals were retained. Nitrate residues were about 400 ppm in the product and NOx destruction exceeded 86%. The demonstration was successful.

D. W. Marshall; N. R. Soelberg

2003-05-01T23:59:59.000Z

430

Sizing sliding gate valves for steam service  

SciTech Connect (OSTI)

Sliding gate valves have been used in thousands of applications during the past 40 yr. While steam control is a common application for these valves, thy are also used to control other gases and liquids. The sliding gate design provides straight-through flow, which minimizes turbulence, vibration, and noise. Seats are self-cleaning and self-lapping to provide a tight, long-lasting shutoff. A correctly sized valve is essential for accurate control. Valve size should be determined by service and system requirements, not by the size of the existing pipeline. Sizing a valve on the basis of pipeline size usually results in an oversized valve and poor control. Generally, regulator size is smaller than pipe size. Whenever complete information is known (inlet pressure, outlet pressure, or pressure drop, and required flow), determine the valve flow coefficient (C{sub v}) using the equations in ANSI/ISA S75.01 or a flow sizing chart. Tables of values for various types of valves are available from manufacturers. However, when complete system requirements are not known, valve oversizing is prevented by determining the design capacity of piping downstream from the valve. The valve should not be sized to pass more flow than the maximum amount the pipe can handle at a reasonable velocity. An example calculation is given.

Bollinger, R. [Jordan Value, Cincinnati, OH (United States)

1995-11-06T23:59:59.000Z

431

Steam generator operating experience, update for 1987--1988  

SciTech Connect (OSTI)

This report summarizes operational events and degradation mechanisms affecting pressurized water reactor steam generator integrity, provides results of 1987 and 1988 steam generator inspections, and highlights both prevalent problem areas and improvements that have been made in nondestructive testing methods, preventive measures, repair techniques, and replacement procedures. It describes the equipment of the three major suppliers and discusses recent examinations of 76 plants. Major areas of concern are the steam generator degradation mechanisms that affect tube integrity or cause tube leakage and tube failure. These include intergranular attack (IGA), intergranular stress corrosion cracking (IGSCC), primary water stress corrosion cracking (PWSCC), pitting, and vibrational wear and fatigue. Also discussed are plugging, sleeving, heat treatment, peening, chemical cleaning, and steam generator replacements, the current status of regulatory instruments and inspection guidelines for ensuring the steam generator integrity, and highlights of steam generator research and unresolved safety issues. The report concludes that cracking, both IGSCC on the tube outside diameter and PWSCC on the tube inside diameter, was the major cause of tube degradation during the 1987--1988 period. 24 refs., 8 tabs.

Frank, L.; Stokley, J.

1989-06-01T23:59:59.000Z

432

FLASH predictions of the MB-2 steam line break tests  

SciTech Connect (OSTI)

If a main steam line from a pressurized water reactor (PWR) steam generator were to rupture, the effect would be a depressurization of the secondary side and a consequential overcooling transient on the primary side. Analyses must accurately predict the effects of the rapid cooldown of the reactor vessel coolant on positive nuclear-kinetic reactivity feedback to the core plus thermal shock to the reactor vessel and other primary system components. Many early studies of the steam line break (SLB) transient made extremely conservative assumptions to maximize the primary to secondary heat transfer which in turn maximized the reactor vessel cooldown rate. Among the more significant of these assumptions was that flow from the break was pure steam and that the tube bundle remained covered until the secondary mass inventory was significantly reduced. The Model F commercial PWR steam generator testing performed in the Model Boiler No. 2 (MB-2) facility located at the Westinghouse Engineering Test Facility in Tampa, Florida provided data to better qualify the actual variation in these key parameters. A conclusion of this analysis is that the MB-2 steam line break data base is accurate and of sufficient detail to provide a valuable basis for making comparisons relative to code predictions. Results obtained using the FLASH transient safety analysis code were found to be in excellent agreement with the data.

Lincoln, F.W.; Coffield, R.D.; Johnson, E.G.

1992-12-31T23:59:59.000Z

433

Development, construction, and use of pneumometric tubes for measurement of steam flow in the steam lines of PVG-1000 at NPP  

SciTech Connect (OSTI)

A system for the direct measurement of steam flow in steam lines after a steam generator, which utilizes a special design of pneumometric tubes and a computing unit that accounts for variation in steam pressure, has been developed to improve the quality of water-level regulation in the steam generators of VVER-1000 power-generating units in the stationary and transitional modes. The advantage of the pneumometric tubes consists in their structural simplicity, high erosion resistance, and absence of irrevocable losses during measurement of steam flow. A similar measurement system is used at foreign NPP. The measurement system in question has been placed in experimental service at the No. 3 unit of the Balakovo NPP, and has demonstrated its worthiness. This measurement system can also be used to determine steam flow in the steam lines of NPP units with VVER-1000 and VVER-440 reactors, and PBMK-1000 power-generating units.

Gorbunov, Yu. S.; Ageev, A. G.; Vasil'eva, R. V.; Korol'kov, B. M. [FGUP 'Elektrogorsk Scientific-Research Center for NPP Safety' (Russian Federation)

2007-05-15T23:59:59.000Z

434

Compton Dry-Cask Imaging System  

ScienceCinema (OSTI)

The Compton-Dry Cask Imaging Scanner is a system that verifies and documents the presence of spent nuclear fuel rods in dry-cask storage and determines their isotopic composition without moving or opening the cask. For more information about this project, visit http://www.inl.gov/rd100/2011/compton-dry-cask-imaging-system/

None

2013-05-28T23:59:59.000Z

435

Compton Dry-Cask Imaging System  

SciTech Connect (OSTI)

The Compton-Dry Cask Imaging Scanner is a system that verifies and documents the presence of spent nuclear fuel rods in dry-cask storage and determines their isotopic composition without moving or opening the cask. For more information about this project, visit http://www.inl.gov/rd100/2011/compton-dry-cask-imaging-system/

None

2011-01-01T23:59:59.000Z

436

Clean Firetube Boiler Waterside Heat Transfer Surfaces, Energy Tips: STEAM, Steam Tip Sheet #7 (Fact Sheet)  

SciTech Connect (OSTI)

A steam energy tip sheet for the Advanced Manufacturing Office (AMO). The prevention of scale formation in firetube boilers can result in substantial energy savings. Scale deposits occur when calcium, magnesium, and silica, commonly found in most water supplies, react to form a continuous layer of material on the waterside of the boiler heat exchange tubes. Scale creates a problem because it typically possesses a thermal conductivity, an order of magnitude less than the corresponding value for bare steel. Even thin layers of scale serve as an effective insulator and retard heat transfer. The result is overheating of boiler tube metal, tube failures, and loss of energy efficiency. Fuel consumption may increase by up to 5% in firetube boilers because of scale. The boilers steam production may be reduced if the firing rate cannot be increased to compensate for the decrease in combustion efficiency. Energy losses as a function of scale thickness and composition are given. Any scale in a boiler is undesirable. The best way to deal with scale is not to let it form in the first place. Prevent scale formation by: (1) Pretreating of boiler makeup water (using water softeners, demineralizers, and reverse osmosis to remove scale-forming minerals); (2) Injecting chemicals into the boiler feedwater; and (3) Adopting proper boiler blowdown practices.

Not Available

2012-04-01T23:59:59.000Z

437

Reliable steam: To cogenerate or not to cogenerate?  

SciTech Connect (OSTI)

Leading industrial companies and institutions are forever seeking new and better ways to reduce their expenses, reduce waste, meet environmental standards, and, in general, improve their bottom-line. One approach to achieving all of these goals is a 100 year-old concept, cogeneration. Many industrial and institutional plants need thermal energy, generally as steam, for manufacturing processes and heating. They also need electric power for motors, lighting, compressed air and air conditioning. Traditionally, these fundamental needs are met separately. Steam is produced with industrial boilers and electricity is purchased from a local utility company. However, these needs can be met at the same time with cogeneration, using the same heat source. Cogeneration is the concurrent production of electrical power and thermal energy from the same heat source. Large steam users commonly take advantage of cogeneration by using high pressure steam with a back pressure turbine to generate electricity, and extract lower pressure steam from the turbine exhaust for their process needs. This approach reduces their electric utility bills while still providing thermal energy for industrial processes. The result is also a more efficient process that uses less total heat and discharges less smoke up the stack. Newer technologies are making cogeneration opportunities available to smaller-sized thermal plants, and electric utility deregulation opportunities are causing many CEOs to seriously consider cogeneration in their manufacturing plants. Whether steam is created through cogeneration or separate generation, many opportunities exist to improve productivity in the distribution system, operation, and maintenance. These opportunities are captured by taking a systems approach, which is promoted by programs such as the Department of Energy's Steam Challenge.

Jaber, D.; Jones, T.; D'Anna, L.; Vetterick, R.

1999-07-01T23:59:59.000Z

438

Dry Transfer Systems for Used Nuclear Fuel  

SciTech Connect (OSTI)

The potential need for a dry transfer system (DTS) to enable retrieval of used nuclear fuel (UNF) for inspection or repackaging will increase as the duration and quantity of fuel in dry storage increases. This report explores the uses for a DTS, identifies associated general functional requirements, and reviews existing and proposed systems that currently perform dry fuel transfers. The focus of this paper is on the need for a DTS to enable transfer of bare fuel assemblies. Dry transfer systems for UNF canisters are currently available and in use for transferring loaded canisters between the drying station and storage and transportation casks.

Brett W. Carlsen; Michaele BradyRaap

2012-05-01T23:59:59.000Z

439

Dry-cleaning of graphene  

SciTech Connect (OSTI)

Studies of the structural and electronic properties of graphene in its pristine state are hindered by hydrocarbon contamination on the surfaces. Also, in many applications, contamination reduces the performance of graphene. Contamination is introduced during sample preparation and is adsorbed also directly from air. Here, we report on the development of a simple dry-cleaning method for producing large atomically clean areas in free-standing graphene. The cleanness of graphene is proven using aberration-corrected high-resolution transmission electron microscopy and electron spectroscopy.

Algara-Siller, Gerardo [Central Facility for Electron Microscopy, Group of Electron Microscopy of Materials Science, Ulm University, Albert-Einstein-Allee 11, Ulm 89081 (Germany); Department of Chemistry, Technical University Ilmenau, Weimarer Strasse 25, Ilmenau 98693 (Germany); Lehtinen, Ossi; Kaiser, Ute, E-mail: ute.kaiser@uni-ulm.de [Central Facility for Electron Microscopy, Group of Electron Microscopy of Materials Science, Ulm University, Albert-Einstein-Allee 11, Ulm 89081 (Germany); Turchanin, Andrey [Faculty of Physics, University of Bielefeld, Universit鋞sstr. 25, Bielefeld 33615 (Germany)

2014-04-14T23:59:59.000Z

440

Microwave drying of ferric oxide pellets  

SciTech Connect (OSTI)

The application of microwave energy for the drying of ferric oxide pellets has been investigated and evaluated. It is shown that the microwave drying rates are much higher than those observed in the conventional process. Also there is some potential for improved quality of the product. As a stand-alone technology it is unlikely that microwave drying would be economical for pellets due to the low cost of conventional fuels. However, based on an understanding of the drying mechanisms in the conventional process and in the microwave process, it is shown that microwave-assisted drying offers considerable potential. In this hybrid process, the advantages of the two drying techniques are combined to provide an improved drying process.

Pickles, C.A.; Xia, D.K. [Queens` Univ., Kingston, Ontario (Canada). Dept. of Materials and Metallurgical Engineering

1997-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Dry melting of high albite  

SciTech Connect (OSTI)

The properties of albitic melts are central to thermodynamic models for synthetic and natural granitic liquids. The authors have analyzed published phase-equilibrium and thermodynamic data for the dry fusion of high albite to develop a more accurate equation for the Biggs free energy of this reaction to 30 kbar and 1,400 C. Strict criteria for reaction reversal were sued to evaluate the phase-equilibrium data, and the thermodynamic properties of solid and liquid albite were evaluated using the published uncertainties in the original measurements. Results suggest that neither available phase-equilibrium experiments nor thermodynamic data tightly constrain the location of the reaction. Experimental solidus temperatures at 1 atm range from 1,100 to 1,120 C. High-pressure experiments were not reversed completely and may have been affected by several sources of error, but the apparent inconsistencies among the results of the various experimentalists are eliminated when only half-reversal data are considered. Uncertainties in thermodynamic data yield large variations in permissible reaction slopes. Disparities between experimental and calculated melting curves are, therefore, largely attributable to these difficulties, and there is no fundamental disagreement between the available phase-equilibrium and thermodynamic data for the dry melting of albite. Consequently, complex speciation models for albitic melts, based on the assumption that these discrepancies represent a real characteristic of the system, are unjustified at this time.

Anovitz, L.M.: Blencoe, J.G.

1999-12-01T23:59:59.000Z

442

Hot Works Procedures and Protocols Last Updated: 2/14/2014 Owner: Safety and Risk Management Director Page 1 of 6  

E-Print Network [OSTI]

Hot Works Procedures and Protocols Last Updated: 2/14/2014 Owner: Safety and Risk Management will log in #12;Hot Works Procedures and Protocols Last Updated: 2/14/2014 Owner: Safety and Risk Director Page 1 of 6 INTRODUCTION The Office of Safety and Risk Management (SRM) has developed, implemented

Dyer, Bill

443

Advanced method for turbine steam path deterioration and performance analysis  

SciTech Connect (OSTI)

The deterioration of a Steam Path affects the efficiency of a turbine. The most critical factors which affect the efficiency of steam and gas turbines are: seals wearing out, deposits, corrosion which causes material losses, solid particle erosion which leads to severe blade trailing edge material losses and others. Computer programs for design analysis of steam and gas turbines were developed. The input data are the steam or gas parameters before and after the turbine, mass flow and the blade path geometry (length, width, diameter, metal angles and clearances). The program calculates steam and gas parameters and their deviation from the design data. The blade path deterioration changes the dimensions such as blade throat, and in extreme cases also the angles. Putting the actual geometry into the program, the deviations from the design points are calculated exactly. The deviations expressed in kW as losses per stage are determined and listed. The paper briefly describes the program algorithm, sensitivity to geometry measurement errors and overall exactitude. Also, examples from field evaluations of some turbines are presented and illustrated. These tools are very helpful to the management the power plants in undertaking a correct decision concerning the date of the next major maintenance and replacement part procurement. The data gathered can be utilized for a more precise performance diagnostic during operation of the turbine.

Kubiak, J.; Angel, F. del; Carnero, A.; Campos, A.; Urquiza, G.; Marino, C.; Villegas, M. [Inst. de Investigaciones Electricas, Temixco, Morelos (Mexico). Div. Sistemas Mecanicos

1996-12-31T23:59:59.000Z

444

Downhole steam generator with improved preheating, combustion and protection features  

DOE Patents [OSTI]

An apparatus for generation of steam in a borehole for penetration into an earth formation wherein feedback preheater means are provided for the fuel and water before entering the combustor assembly. First, combustion gases are conducted from the combustion chamber to locations in proximity to the water and fuel supplies. Secondly, both hot combustion gases and steam are conducted from the borehole back to the water and fuel supply. The water used for conversion to steam is passed in a countercurrent manner through a plurality of annular water flow channels surrounding the combustion chamber. In this manner, the water is preheated, and the combustion chamber is cooled simultaneously, thereby minimizing thermal stresses and deterioration of the walls of the combustion chamber. The water is injected through slotted inlets along the combustion chamber wall to provide an unstable boundary layer and stripping of the water from the wall for efficient steam generation. Pressure responsive doors are provided at the steam outlet of the combustor assembly. The outlet doors and fluid flow functions may be controlled by a diagnostic/control module. The module is positioned in the water flow channel to maintain a relatively constant, controlled temperature.

Fox, Ronald L. (Albuquerque, NM)

1983-01-01T23:59:59.000Z

445

Bore tube assembly for steam cooling a turbine rotor  

DOE Patents [OSTI]

An axial bore tube assembly for a turbine is provided to supply cooling steam to hot gas components of the turbine wheels and return the spent cooling steam. A pair of inner and outer tubes define a steam supply passage concentric about an inner return passage. The forward ends of the tubes communicate with an end cap assembly having sets of peripheral holes communicating with first and second sets of radial tubes whereby cooling steam from the concentric passage is supplied through the end cap holes to radial tubes for cooling the buckets and return steam from the buckets is provided through the second set of radial tubes through a second set of openings of the end cap into the coaxial return passage. A radial-to-axial flow transitioning device, including anti-swirling vanes is provided in the end cap. A strut ring adjacent the aft end of the bore tube assembly permits axial and radial thermal expansion of the inner tube relative to the outer tube.

DeStefano, Thomas Daniel (Ballston Lake, NY); Wilson, Ian David (Clifton Park, NY)

2002-01-01T23:59:59.000Z

446

Steam exit flow design for aft cavities of an airfoil  

DOE Patents [OSTI]

Turbine stator vane segments have inner and outer walls with vanes extending therebetween. The inner and outer walls have impingement plates. Steam flowing into the outer wall passes through the impingement plate for impingement cooling of the outer wall surface. The spent impingement steam flows into cavities of the vane having inserts for impingement cooling the walls of the vane. The steam passes into the inner wall and through the impingement plate for impingement cooling of the inner wall surface and for return through return cavities having inserts for impingement cooling of the vane surfaces. A skirt or flange structure is provided for shielding the steam cooling impingement holes adjacent the inner wall aerofoil fillet region of the nozzle from the steam flow exiting the aft nozzle cavities. Moreover, the gap between the flash rib boss and the cavity insert is controlled to minimize the flow of post impingement cooling media therebetween. This substantially confines outflow to that exiting via the return channels, thus furthermore minimizing flow in the vicinity of the aerofoil fillet region that may adversely affect impingement cooling thereof.

Storey, James Michael (Clifton Park, NY); Tesh, Stephen William (Simpsonville, SC)

2002-01-01T23:59:59.000Z

447

Multifaceted Value Profiles of Forest Owner Categories in South Sweden: The River Helge a Catchment as a Case Study  

E-Print Network [OSTI]

-industrial forest land owners and municipalities included all value categories, the forest companies focused on wood including non-timber forest products as well as ecological, social, and cultural dimensions at multiple goods (e.g., timber and fish) can readily be converted into market goods. In contrast, many

Vermont, University of

448

2009-2010 Special Projects Boellstorff: A Southern Region Well Owner Network to Safeguard Private Well and Aquifer Integrity  

E-Print Network [OSTI]

, improper well construction techniques, abandoned wells, improperly sited and functioning on-site wastewater treatment systems, and changes in land use. The aim of the proposed Southern Region Well Owner Network integrity. The SRWON will improve rural and rural-urban interface environmental management by providing

449

Group Member Names: ________________________________________________ Scenario: You are the owner of a potato plant in Idaho. You have recently won a contract  

E-Print Network [OSTI]

: ________________________________________________ ________________________________________________ ________________________________________________ Scenario: You are the owner of a potato plant in Idaho. You have recently won a contract to supply McDonald's with potatoes. McDonald's requires their suppliers to precut and freeze the potatoes before shipping to their distributing center. Your potato plant does not currently have a process for precutting and freezing potatoes

Provancher, William

450

Pet owners have the responsibility to care for the well being of their animals. Your ability to  

E-Print Network [OSTI]

Pet owners have the responsibility to care for the well being of their animals. Your ability to care for an animal can help determine what kind of animal you select as a pet. Out-of-Town Emergency Pamphlet, "Emergency Preparedness for Your Pets," 2003. Veterinarians in Your County or City Name

451

Empowering the Application Owner As the IT landscape evolves, two distinct roles are emerging in the enterprise: the provider  

E-Print Network [OSTI]

in the enterprise: the provider of IT services (usually the datacenter administrator) and the consumer of IT services (the application owner). Datacenter administrators build the infrastructure for their business on datacenter administrators are increasing, yet they must continue to meet their organization's commitment

Chaudhuri, Surajit

452

Effect of steam partial pressure on gasification rate and gas composition of product gas from catalytic steam gasification of HyperCoal  

SciTech Connect (OSTI)

HyperCoal was produced from coal by a solvent extraction method. The effect of the partial pressure of steam on the gasification rate and gas composition at temperatures of 600, 650, 700, and 750{sup o}C was examined. The gasification rate decreased with decreasing steam partial pressure. The reaction order with respect to steam partial pressure was between 0.2 and 0.5. The activation energy for the K{sub 2}CO{sub 3}-catalyzed HyperCoal gasification was independent of the steam partial pressure and was about 108 kJ/mol. The gas composition changed with steam partial pressure and H{sub 2} and CO{sub 2} decreased and CO increased with decreasing steam partial pressure. By changing the partial pressure of the steam, the H{sub 2}/CO ratio of the synthesis gas can be controlled. 18 refs., 7 figs., 2 tabs.

Atul Sharma; Ikuo Saito; Toshimasa Takanohashi [National Institute of Advanced Industrial Science and Technology, Ibaraki (Japan). Advanced Fuel Group

2009-09-15T23:59:59.000Z

453

Life assessment product catalog for boilers, steam pipes, and steam turbines  

SciTech Connect (OSTI)

Aging fossil power plants, escalating costs of new plant construction, and load growth rate uncertainties are motivating utilities to make the most effective use of critical components in existing power plants. To help meet this need, EPRI has refined existing methods and developed new methods of predicting the remaining life of key fossil plant components with greater accuracy and confidence. This report describes 16 EPRI products (guidelines, computer programs, and other tools) that apply these techniques to boiler tubes, boiler headers, steam lines, and turbine rotors, blades, and casings. Utility personnel, including plant engineers, maintenance supervisor, engineering department staff, plant operating staff, and performance engineers, can use these products to assess remaining component life, as well as to set cost-effective maintenance procedures, inspection schedules, and operating procedures.

Hoffman, S. (Hoffman (S.), Santa Clara, CA (United States))

1992-07-01T23:59:59.000Z

454

Warming systems prolong steam-turbine life, accelerate startup  

SciTech Connect (OSTI)

Cycling capability is one of the top challenges in the design, operation, and maintenance of today's powerplants. This article describes how permanent warming systems can be a powerful ally in meeting this challenge, particularly for aging steam turbines. The warming system is typically used to hold steam-turbine shell temperatures during short shutdowns (up to about three days), or to pre-warm shells after longer shut-downs. Permanent warming systems elevate metal temperature above 500 F, distinguishing them from heat tracing systems that operate at much lower temperatures for freeze protection or viscosity control. Permanent warming systems can reduced steam-turbine damage during both startup heating and off-line cooling, and can reduce plant startup time.

Swanekamp, R.

1994-08-01T23:59:59.000Z

455

Steam driven centrifugal pump for low cost boiler feed service  

SciTech Connect (OSTI)

This article describes a steam driven centrifugal pump for boiler feed-water and other high pressure water applications, which was awarded Top Honors in the special pumps category of the 1982 Chemical processing Vaaler competition, because the simple design with turbine, pump and controls combined in an integral unit provides high operating efficiency and reliable performance with minimal maintenance. Single source responsibility for all components when the pump may have to be serviced is another advantage. These features meet the requirements for boiler feed pumps that are critical to maintaining a consistent steam supply in a process plant where downtime can be extremely expensive. The annual cost to operate the pump for 8000 hours is about $100,000, if electricity costs 5 cents/kwh. These pumps can be run for about $30,000 on steam, if natural gas costs $4.00/mcf. Cost savings are $70,000 annually.

Not Available

1982-11-01T23:59:59.000Z

456

Method and apparatus for removing micronized coal from steam  

SciTech Connect (OSTI)

Micronized coal is removed from coal-bearing steam by spraying stabilized petroleum oil into the steam and directing the resultant stream at a separation surface on which a coal-oil slurry is deposited and collected. Apparatus includes conduits which direct the resultant stream downward into a housing and normal to a surface on which the slurry is deposited by impact forces. In additional apparatus disclosed, the resultant stream is directed from a horizontal conduit circumferentially along the interior wall of a horizontally disposed cylindrical chamber at the top of the chamber and the coal-oil slurry deposited on the wall by centrifugal force is collected in a trough situated below a longitudinal slot at the bottom of the chamber. In both types of apparatus, after separation of the slurry the velocity of the steam is reduced to settle out remaining oil droplets and is then discharged to the atmosphere.

Vlnaty, J.

1980-10-14T23:59:59.000Z

457

Industrialization and Urbanization: Did the Steam Engine Contribute to the Growth of Cities in the United States?  

E-Print Network [OSTI]

in the Century of the Steam Engine, Vol. 1. University Pressat Work: The Corliss Steam Engine in the Late-Nineteenth-and Adoption of the Steam Engine in American Manufacturing,

Kim, Sukkoo

2004-01-01T23:59:59.000Z

458

Energy Savings Accomplished by Replacing Steam Ejectors with Electric Driven Vacuum Pumps in Crude Distillation Vacuum Towers  

E-Print Network [OSTI]

The low cost of steam combined with the maintenance free operation of steam ejectors has assured their unquestioned use in providing the necessary vacuum for crude distillation vacuum towers. However, the cost of steam production has risen...

Nelson, R. E.

1982-01-01T23:59:59.000Z

459

A simplified model of decontamination by BWR steam suppression pools  

SciTech Connect (OSTI)

Phenomena that can decontaminate aerosol-laden gases sparging through steam suppression pools of boiling water reactors during reactor accidents are described. Uncertainties in aerosol properties, aerosol behavior within gas bubbles, and bubble behavior in plumes affect predictions of decontamination by steam suppression pools. Uncertainties in the boundary and initial conditions that are dictated by the progression of severe reactor accidents and that will affect predictions of decontamination by steam suppression pools are discussed. Ten parameters that characterize boundary and initial condition uncertainties, nine parameters that characterize aerosol property and behavior uncertainties, and eleven parameters that characterize uncertainties in the behavior of bubbles in steam suppression pools are identified. Ranges for the values of these parameters and subjective probability distributions for parametric values within the ranges are defined. These uncertain parameters are used in Monte Carlo uncertainty analyses to develop uncertainty distributions for the decontamination that can be achieved by steam suppression pools and the size distribution of aerosols that do emerge from such pools. A simplified model of decontamination by steam suppression pools is developed by correlating features of the uncertainty distributions for total decontamination factor, DF(total), mean size of emerging aerosol particles, d{sub p}, and the standard deviation of the emerging aerosol size distribution, {sigma}, with pool depth, H. Correlations of the median values of the uncertainty distributions are suggested as the best estimate of decontamination by suppression pools. Correlations of the 10 percentile and 90 percentile values of the uncertainty distributions characterize the uncertainty in the best estimates. 295 refs., 121 figs., 113 tabs.

Powers, D.A.

1997-05-01T23:59:59.000Z

460

Superalloys for ultra supercritical steam turbines--oxidation behavior  

SciTech Connect (OSTI)

Goals of the U.S. Department of Energy抯 Advanced Power Systems Initiatives include power generation from coal at 60% efficiency, which requires steam conditions of up to 760 癈 and 340 atm, so called ultra-supercritical (USC) steam conditions. One of the important materials performance considerations is steam-side oxidation resistance. Evaporation of protective chromia scales is expected to be a primary corrosion mechanism under USC conditions. A methodology to calculate Cr evaporation rates from chromia scales with cylindrical geometries was developed that allows for the effects of CrO2(OH)2 saturation within the gas phase. This approach was combined with Cr diffusion calculations within the alloy (with a constant flux of Cr leaving the alloy from evaporation) to predict Cr concentration profiles as a function of exposure time and to predict the time until the alloy surface concentration of Cr reaches zero. This time is a rough prediction of the time until breakaway oxidation. A hypothetical superheater tube, steam pipe, and high pressure turbine steam path was examined. At the highest temperatures and pressures, the time until breakaway oxidation was predicted to be quite short for the turbine blade, and of concern within the steam pipe and the higher temperature portions of the superheater tube. The predicted time until breakaway oxidation increases dramatically with decreases in temperature and total pressure. Possible mitigation techniques were discussed, including those used in solid oxide fuel cell metallic interconnects (lowering the activity of Cr in the oxide scale by adding Mn to the alloy), and thermal barrier coating use on high pressure turbine blades for both erosion and chromia evaporation protection.

Holcomb, G.R.

2008-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Hydrogen generation utilizing integrated CO2 removal with steam reforming  

DOE Patents [OSTI]

A steam reformer may comprise fluid inlet and outlet connections and have a substantially cylindrical geometry divided into reforming segments and reforming compartments extending longitudinally within the reformer, each being in fluid communication. With the fluid inlets and outlets. Further, methods for generating hydrogen may comprise steam reformation and material adsorption in one operation followed by regeneration of adsorbers in another operation. Cathode off-gas from a fuel cell may be used to regenerate and sweep the adsorbers, and the operations may cycle among a plurality of adsorption enhanced reformers to provide a continuous flow of hydrogen.

Duraiswamy, Kandaswamy; Chellappa, Anand S

2013-07-23T23:59:59.000Z

462

Effects of Reinsulating Underground Steam Pipes- A Case Study  

E-Print Network [OSTI]

-13, 1999 Figure 5. The pumping process on the street. FINDINGS Line Losses The following table shows the monthly average steam flow rates in pounds per hour for each of the meters since January 1997. For September and October 1998, electric power... of the 12" and 8" diameter piping. There are six steam vaults between the two-meter 167 ESL-IE-99-05-24 Proceedings from the Twenty-first National Industrial Energy Technology Conference, Houston, TX, May 12-13, 1999 -- ------ locations. These vaults...

Mentzer, T.

463

Recovery of bitumen from oil sand by steam with chemicals  

SciTech Connect (OSTI)

Recently, oil sand bitumen has become the center of attention as a possible oil energy substitute for the future. Until now, the development of oil sand has been performed by surface miing and conventional steam injection, these methods are limited in respect to resource recovery. A more effective method needs to be developed utilizing in situ recovery. In this study, a new attempt is made for the purpose of enhancing the recovery of bitumen from oil sand by adopting the method of injecting high pressure steam and chemicals such as solvents, surfactants, and others.

Yamazaki, T.

1988-01-01T23:59:59.000Z

464

Method to prevent/mitigate steam explosions in casting pits  

DOE Patents [OSTI]

Steam explosions can be prevented or mitigated during a metal casting process by the placement of a perforated flooring system in the casting pit. An upward flow of compressed gas through this perforated flooring system is introduced during the casting process to produce a buffer layer between any spilled molten metal and the cooling water in the reservoir. This buffer layer provides a hydrodynamic layer which acts to prevent or mitigate steam explosions resulting from hot, molten metal being spilled into or onto the cooling water.

Taleyarkhan, Rusi P. (Knoxville, TN)

1996-01-01T23:59:59.000Z

465

FLUIDIZABLE CATALYSTS FOR PRODUCING HYDROGEN BY STEAM REFORMING BIOMASS PYROLYSIS LIQUIDS  

E-Print Network [OSTI]

FLUIDIZABLE CATALYSTS FOR PRODUCING HYDROGEN BY STEAM REFORMING BIOMASS PYROLYSIS LIQUIDS Kimberly established that biomass pyrolysis oil could be steam-reformed to generate hydrogen using non pyrolysis oil could be almost stoichiometrically converted to hydrogen. However, process performance

466

CO2 Reduction through Optimization of Steam Network in Petroleum Refineries: Evaluation of New Scenario  

E-Print Network [OSTI]

Steam network of petroleum refinery is energy intensive, and consequently contribute significantly to the greenhouse gases emissions. A simple model for the estimation of CO2 emissions associated with operation of steam network as encountered...

Manesh, M. H. K; Khodaie, H.; Amidpour, M.

2008-01-01T23:59:59.000Z

467

Revitalization of a Steam Lab to Meet Energy Challenge and Strengthen Mechanical Engineering Education  

E-Print Network [OSTI]

An 'old' and 'obsolete' boiler system was revitalized and an enhanced Steam Lab was established based on that system. In this project, modifications and improvements were made to the facility, which contains a 150 BHP boiler, condenser, steam...

Kozman, T.; Simon, W. E.; Guidry, J.; Liu, Y.

2011-01-01T23:59:59.000Z

468

E-Print Network 3.0 - analyzing steam generator Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the early develop- ment of high-pressure steam... A History of the Growth of the Steam Engine (1883) Hero of Alexandria, who lived around 60 AD, con- ducted Source: Leveson,...

469

E-Print Network 3.0 - advanced steam temperatures Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

adiabatic process changes the temperature of the gas without heating it. 12;DC A steam engine and a Ferrari... water at the same temperature. Assume that water and steam,...

470

E-Print Network 3.0 - area steam plants Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Renewables 79 copyright Summary: Figure 1: 50 kW prototype solar power plant using Steam Engine Induction Generator Paraboloid dish... Modelling of a 400m2 steam based...

471

The Passenger Steamboat Phoenix: An Archaeological Study of Early Steam Propulsion in North America  

E-Print Network [OSTI]

The advent of steam contributed heavily to the economic transformation of early America, facilitating trade through the transportation of goods along the country抯 lakes, rivers, and canals. Serious experimentation with steam navigation began...

Schwarz, George 1977-

2012-08-31T23:59:59.000Z

472

Generating Electricity with your Steam System: Keys to Long Term Savings  

E-Print Network [OSTI]

The application of combined heat and power principals to existing plant steam systems can help produce electricity at more than twice efficiency of grid generated electricity. In this way, steam plant managers can realize substantial savings...

Bullock, B.; Downing, A.

2010-01-01T23:59:59.000Z

473

From Basic Control to Optimized Systems-Applying Digital Control Systems to Steam Boilers  

E-Print Network [OSTI]

This presentation examines the application of Distributed Digital Controls in order to review the application of this recent control technology towards Steam Boilers in a step-by-step manner. The main purpose of a steam generating boiler...

Hockenbury, W. D.

1982-01-01T23:59:59.000Z

474

Energy Comparison Vacuum Producing Equipment - Mechanical Vacuum Pumps vs. Steam Ejectors  

E-Print Network [OSTI]

vacuum on condensers, process reactors, or equipment and processes requiring subatmospheric conditions, has been to utilize steam ejectors. Due to the inherent operating inefficiency and wastefulness of the steam ejector, coupled with the rapidly...

Foisy, E. C.; Munkittrick, M. T.

1982-01-01T23:59:59.000Z

475

Flash High-Pressure Condensate to Regenerate Low-Pressure Steam  

SciTech Connect (OSTI)

This revised ITP tip sheet on regenerating low-pressure steam provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

476

EVALUATION OF A SULFUR OXIDE CHEMICAL HEAT STORAGE PROCESS FOR A STEAM SOLAR ELECTRIC PLANT  

E-Print Network [OSTI]

CHEMICAL HEAT STORAGE PROCESS FOR A STEAM SOLAR ELECTRICCHEMICAL HEAT STORAGE PROCESS FOR A STEAM SOLAR ELECTRICprocess Boeing solar receiver [5J Internal detail of Boeing solar receiver [5J . 2.4 Heat

Dayan, J.

2011-01-01T23:59:59.000Z

477

Catalytic roles of Co0 and Co2+ during steam reforming of ethanol...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

roles of Co0 and Co2+ during steam reforming of ethanol on CoMgO catalysts . Catalytic roles of Co0 and Co2+ during steam reforming of ethanol on CoMgO catalysts . Abstract:...

478

A Comparative Study between Co and Rh for Steam Reforming of...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

between Co and Rh for Steam Reforming of Ethanol. A Comparative Study between Co and Rh for Steam Reforming of Ethanol. Abstract: Rh and Co-based catalyst performance was compared...

479

Three dimensional effects in analysis of PWR steam line break accident  

E-Print Network [OSTI]

A steam line break accident is one of the possible severe abnormal transients in a pressurized water reactor. It is required to present an analysis of a steam line break accident in the Final Safety Analysis Report (FSAR) ...

Tsai, Chon-Kwo

480

Experimental investigation of over-expanded supersonic steam jet submerged in quiescent water  

SciTech Connect (OSTI)

This study was designed to determine the behaviour of an over-expanded supersonic steam jet in quiescent water. Only two shapes of steam plume were observed and an analytical model was constructed. The axial and radial temperature distributions were measured in the steam plume and in the surrounding water. The flow pattern and temperature distributions were influenced mainly by steam mass flux and water temperature. The results confirmed the occurrence of compression and expansion waves in the steam plume, and indicated that the temperature distributions reflected the steam plume shapes. The axial temperature distributions in the forepart of the steam plume were independent of water temperature. Empirical correlations were found that predicted the dimensionless axial and radial temperatures of the turbulent jet region. Moreover, prediction of the steam plume length by the dimensionless axial temperature showed good agreement with the experimental results. (author)

Wu, Xin-Zhuang; Yan, Jun-Jie; Li, Wen-Jun; Pan, Dong-Dong; Liu, Guang-Yao [State Key Laboratory of Multiphase Flow in Power Engineering, Xi'an Jiaotong University, Xi'an 710049 (China)

2010-01-15T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Use Vapor Recompression to Recover Low-Pressure Waste Steam (Revised0  

SciTech Connect (OSTI)

This revised ITP tip sheet on recovering low-pressure waste steam provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2008-03-01T23:59:59.000Z

482

Modelling of a Coil Steam Generator for Concentrated Solar Power Applications.  

E-Print Network [OSTI]

??The project investigates a new design for a CSP plant steam generation system, the Coil Steam Generator(CSG). This system allows faster start-ups and therefore higher (more)

PELAGOTTI, LEONARDO

2014-01-01T23:59:59.000Z

483

Experimental studies of steam-propane injection for the Duri intermediate crude oil  

E-Print Network [OSTI]

Laboratory experimental studies were carried out to better understand production mechanisms involved in steam-propane injection and to investigate effects of expected field pressure and temperature conditions on steam-propane injection...

Hendroyono, Arief

2003-01-01T23:59:59.000Z

484

FINAL REPORT: Transformational electrode drying process  

SciTech Connect (OSTI)

This report includes major findings and outlook from the transformational electrode drying project performance period from January 6, 2012 to August 1, 2012. Electrode drying before cell assembly is an operational bottleneck in battery manufacturing due to long drying times and batch processing. Water taken up during shipment and other manufacturing steps needs to be removed before final battery assembly. Conventional vacuum ovens are limited in drying speed due to a temperature threshold needed to avoid damaging polymer components in the composite electrode. Roll to roll operation and alternative treatments can increase the water desorption and removal rate without overheating and damaging other components in the composite electrode, thus considerably reducing drying time and energy use. The objective of this project was the development of an electrode drying procedure, and the demonstration of processes with no decrease in battery performance. The benchmark for all drying data was an 80癈 vacuum furnace treatment with a residence time of 18 22 hours. This report demonstrates an alternative roll to roll drying process with a 500-fold improvement in drying time down to 2 minutes and consumption of only 30% of the energy compared to vacuum furnace treatment.

Claus Daniel, C.; Wixom, M. (A123 Systems, Inc.)

2013-12-19T23:59:59.000Z

485

Cold vacuum drying system conceptual design report  

SciTech Connect (OSTI)

This document summarizes the activities involved in the removal of the SNF from the leaking basins and to place it in stable dry storage.

Bradshaw, F.W.

1996-05-01T23:59:59.000Z

486

Cold vacuum drying facility design requirements  

SciTech Connect (OSTI)

This document provides the detailed design requirements for the Spent Nuclear Fuel Project Cold Vacuum Drying Facility. Process, safety, and quality assurance requirements and interfaces are specified.

IRWIN, J.J.

1999-07-01T23:59:59.000Z

487

,"New York Dry Natural Gas Proved Reserves"  

U.S. Energy Information Administration (EIA) Indexed Site

Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","New York Dry Natural Gas Proved Reserves",10,"Annual",2013,"6301977" ,"Release Date:","124...

488

Using and Storing Nonfat Dry Milk Nonfat dry milk is convenient to store, easy to use and  

E-Print Network [OSTI]

in a cool, dry place. s Dry milk products are very sensitive to temperature and humidity. The area where your dry milk is stored should be kept as cool as possible. s Dry milk will absorb moisture and odorsUsing and Storing Nonfat Dry Milk Nonfat dry milk is convenient to store, easy to use

489

Exergy Analysis of the Steam Network in Tehran Oil Refinery and Evaluation with New Scenario  

E-Print Network [OSTI]

Exergy Analysis of the Steam Network in Tehran Oil Refinery and evaluation with New Scenario Hassan Khodaei JA Ramin Taheri seresht Reza Arghandeh Energy system Lab Chairman of the Board of Directors... oil refinery, Exergy Analysis, Steam Network, Retrofit, Optimization 1. INTRODUCTION Refinery steam network is considered as a unit that consumes energy greatly. The main objective of the network is to produce the steam, which is required...

Khodaei, H.; Taheri, R.; Arghandeh, R.

490

Energy Management of Steam Distribution Systems Through Energy Audits and Computerized Reporting Programs  

E-Print Network [OSTI]

ENERGY KANAGEKBNT OF STEAM DISTRIBUTION SYSTEMS THROUGH BNKRGY AUDITS AND COItPlTl'ERIZED REPORTING PROGRAtIS NORMAN J. RIVERS and HARTIN MANDZUK Armstrong Machine Works, Inc. Three Rivers, Michigan ABSTRACT This presentation will highlight... the economic losses associated with steam distribution systems and how to establish good energy management programs to reduce energy cost by 15 to 25 percent. Recognizing energy losses in steam systems involves I 1. Steam lost through defective valves...

Rivers, N.; Mandzuk, N.

491

Case Study: Lessons Learned From Converting Electric Chillers to Steam Chillers in a Electric Deregulated Market.  

E-Print Network [OSTI]

was that a flatter load profile due to steam cooling should allow better electric pricing from energy suppliers....

Wohl, J.

492

Water Vapor and Mechanical Work: A Comparison of Carnot and Steam Cycles OLIVIER PAULUIS  

E-Print Network [OSTI]

by the corresponding Carnot cycle. The Carnot and steam cycles can be combined into a mixed cycle that is forcedWater Vapor and Mechanical Work: A Comparison of Carnot and Steam Cycles OLIVIER PAULUIS Center in the atmosphere is discussed here by comparing two idealized heat engines: the Carnot cycle and the steam cycle

Pauluis, Olivier M.

493

Re ning Abstract Machine Speci cations of the Steam Boiler Control to Well Documented  

E-Print Network [OSTI]

Re ning Abstract Machine Speci cations of the Steam Boiler Control to Well Documented Executable the steam boiler control speci cation problem to il- lustrate how the evolving algebra approach to the speci, in June 1995, to control the Karlsruhe steam boiler simulator satisfactorily. The abstract machines

B枚rger, Egon

494

An Algebraic Speci cation of the Steam-Boiler Control System  

E-Print Network [OSTI]

An Algebraic Speci#12;cation of the Steam-Boiler Control System Michel Bidoit 1 , Claude Chevenier describe how to derive an algebraic speci#12;cation of the Steam-Boiler Control System starting from to specify the detection of the steam-boiler fail- ures. Finally we discuss validation and veri#12;cation

Bidoit, Michel

495

Combined Steam Reforming and Partial Oxidation of Methane to Synthesis Gas under Electrical Discharge  

E-Print Network [OSTI]

Combined Steam Reforming and Partial Oxidation of Methane to Synthesis Gas under Electrical production from simultaneous steam reforming and partial oxidation of methane using an ac corona discharge production has been steam reforming, shown in reaction 4. It is very useful to use low-cost materials

Mallinson, Richard

496

Towards model-based control of a steam Rankine process for engine waste heat recovery  

E-Print Network [OSTI]

Towards model-based control of a steam Rankine process for engine waste heat recovery Johan Peralez steam process for exhaust gas heat recovery from a spark-ignition engine, focusing in particular results on a steam process for SI engines, [3] on generic control issues and [4] which provides a comp

Paris-Sud XI, Universit茅 de

497

DIRECT STEAM GENERATION USING THE SG4 500m2 PARABOLOIDAL DISH CONCENTRATOR  

E-Print Network [OSTI]

conveyed the steam to our 50 kWe steam turbine; the new dish is oversized for the current engine, so someDIRECT STEAM GENERATION USING THE SG4 500m2 PARABOLOIDAL DISH CONCENTRATOR Greg Burgess 1 , Keith School of Engineering (RSE), Australian National University (ANU), Canberra, ACT, 0200, Australia, Phone

498

Steam BestPractice Resources and Tools: "Old" News is "New" News!  

E-Print Network [OSTI]

system efficiency. The Steam BestPractice effort, a part of the DOE-OIT effort, has identified and documented an extensive group of steam system resources and tools to assist steam system users to improve their systems. This paper describes the "new" news...

Wright, A.; Hart, F.; Russell, C.; Jaber, D.

499

Results From the Industrial Assessment Center (IAC) Steam Tool Benchmarking Support Project  

E-Print Network [OSTI]

developed is the "Steam System Scoping Tool." In the summer of 2001, six of the DOE Industrial Assessment Centers (IACs) completed a project to provide data on the usefulness of the Steam System Scoping Tool. These six IACs performed eighteen plant steam...

Wright, A. L.; Bassett, K.; Eckerlin, H.; Ganji, A.; Hengeveld, D.; Jendrucko, R.; Kosanovic, D.; Turner, W.

500

Enhanced Oil Recovery through Steam Assisted Gravity Drainage January 22, 2014  

E-Print Network [OSTI]

Enhanced Oil Recovery through Steam Assisted Gravity Drainage January 22, 2014 A Comparative Study Of Continuous And Cyclic Steam Injection With Trapping Of Oil Phase Muhammad Adil Javed Summary of Thesis Enhanced oil recovery (EOR) through steam-assisted gravity drainage (SAGD) has become an important in

Cirpka, Olaf Arie