Powered by Deep Web Technologies
Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Steam atmosphere drying exhaust steam recompression system  

DOE Patents (OSTI)

This invention relates to a heated steam atmosphere drying system comprising dryer in combination with an exhaust recompression system which is extremely energy efficient and eliminates dangers known to air dryers. The system uses superheated steam as the drying medium, which recirculates through the system where its heat of evaporation and heat of compression is recovered, thereby providing a constant source of heat to the drying chamber. The dryer has inlets whereby feedstock and superheated steam are fed therein. High heat transfer and drying rates are achieved by intimate contact of the superheated steam with the particles being dried. The dryer comprises a vessel which enables the feedstock and steam to enter and recirculate together. When the feedstock becomes dry it will exit the dryer with the steam and become separated from the steam through the use of a curvilinear louver separator (CLS). The CLS enables removal of fine and ultrafine particles from the dryer. Water vapor separated from the particles in the CLS as superheated steam, may then be recovered and recirculated as steam through the use of a compressor to either directly or indirectly heat the dryer, and a heat exchanger or a heater to directly provide heat to the dryer. This system not only provides a very efficient heat transfer system but results in a minimum carry-over of ultrafine particles thereby eliminating any explosive hazard. 17 figures.

Becker, F.E.; Smolensky, L.A.; Doyle, E.F.; DiBella, F.A.

1994-03-08T23:59:59.000Z

2

Steam atmosphere drying exhaust steam recompression system  

DOE Patents (OSTI)

This invention relates to a heated steam atmosphere drying system comprising dryer in combination with an exhaust recompression system which is extremely energy efficient and eliminates dangers known to air dryers. The system uses superheated steam as the drying medium, which recirculated through the system where its heat of evaporation and heat of compression is recovered, thereby providing a constant source of heat to the drying chamber. The dryer has inlets whereby feedstock and superheated steam are fed therein. High heat transfer and drying rates are achieved by intimate contact of the superheated steam with the particles being dried The dryer comprises a vessel which enables the feedstock and steam to enter recirculate together. When the feedstock becomes dry it will exit the dryer with the steam and become separated from the steam through the use of a curvilinear louver separator (CLS). The CLS enables removal of fine and ultrafine particles from the dryer. Water vapor separated from the particles in the CLS as superheated steam, may then be recovered and recirculated as steam through the use of a compressor to either directly or indirectly heat the dryer, and a heat exchanger or a heater to directly provide heat to the dryer. This system not only provides a very efficient heat transfer system but results in a minimum carry-over of ultrafine particles thereby eliminating any explosive hazard.

Becker, Frederick E. (Reading, MA); Smolensky, Leo A. (Concord, MA); Doyle, Edward F. (Dedham, MA); DiBella, Francis A. (Roslindale, MA)

1994-01-01T23:59:59.000Z

3

Steam atmosphere drying concepts using steam exhaust recompression  

SciTech Connect

In the US industrial drying accounts for approximately 1.5 quads of energy use per year. Annual industrial dryer expenditures are estimated to be in the $500 million range. Industrial drying is a significant energy and monetary expense. For the thermal drying processes in which water is removed via evaporation from the feedstock, attempts have been made to reduce the consumption of energy using exhaust waste heat recovery techniques, improved dryer designs, or even the deployment of advanced mechanical dewatering techniques. Despite these efforts, it is obvious that a large amount of thermal energy is often still lost if the latent heat of evaporation from the evaporated water cannot be recovered and/or in some way be utilized as direct heat input into the dryer. Tecogen Inc. is conducting research and development on an industrial drying concept. That utilizes a directly or indirectly superheated steam cycle atmosphere with exhaust steam recompression to recover the latent heat in the exhaust that would otherwise be lost. This approach has the potential to save 55 percent of the energy required by a conventional air dryer. Other advantages to the industrial dryer user include: A 35-percent reduction in the yearly cost per kg{sub evap} to dry wet feedstock, Reduced airborne emissions, Reduced dry dust fire/explosion risks, Hot product not exposed to oxygen thus, the product quality is enhanced, Constant rate drying in steam atmosphere, Reduced dryer size and cost, Reduced dryer heat losses due to lower dryer inlet temperatures. Tecogen has projected that the steam atmosphere drying system is most suitable as a replacement technology for state-of-the-art spray, flash, and fluidized bed drying systems. Such systems are utilized in the food and kindred products; rubber products; chemical and allied products; stone, clay, and glass; textiles; and pulp and paper industrial sectors.

DiBella, F.A. [TECOGEN, Inc., Waltham, MA (United States)

1992-08-01T23:59:59.000Z

4

Steam atmosphere drying concepts using steam exhaust recompression  

SciTech Connect

In the US industrial drying accounts for approximately 1.5 quads of energy use per year. Annual industrial dryer expenditures are estimated to be in the $500 million range. Industrial drying is a significant energy and monetary expense. For the thermal drying processes in which water is removed via evaporation from the feedstock, attempts have been made to reduce the consumption of energy using exhaust waste heat recovery techniques, improved dryer designs, or even the deployment of advanced mechanical dewatering techniques. Despite these efforts, it is obvious that a large amount of thermal energy is often still lost if the latent heat of evaporation from the evaporated water cannot be recovered and/or in some way be utilized as direct heat input into the dryer. Tecogen Inc. is conducting research and development on an industrial drying concept. That utilizes a directly or indirectly superheated steam cycle atmosphere with exhaust steam recompression to recover the latent heat in the exhaust that would otherwise be lost. This approach has the potential to save 55 percent of the energy required by a conventional air dryer. Other advantages to the industrial dryer user include: A 35-percent reduction in the yearly cost per kg[sub evap] to dry wet feedstock, Reduced airborne emissions, Reduced dry dust fire/explosion risks, Hot product not exposed to oxygen thus, the product quality is enhanced, Constant rate drying in steam atmosphere, Reduced dryer size and cost, Reduced dryer heat losses due to lower dryer inlet temperatures. Tecogen has projected that the steam atmosphere drying system is most suitable as a replacement technology for state-of-the-art spray, flash, and fluidized bed drying systems. Such systems are utilized in the food and kindred products; rubber products; chemical and allied products; stone, clay, and glass; textiles; and pulp and paper industrial sectors.

DiBella, F.A. (TECOGEN, Inc., Waltham, MA (United States))

1992-08-01T23:59:59.000Z

5

Experimental and analytical studies of hydrocarbon yields under dry-, steam-, and steam with propane-distillation  

E-Print Network (OSTI)

Recent experimental and simulation studies -conducted at the Department of Petroleum Engineering at Texas A&M University - confirm oil production is accelerated when propane is used as an additive during steam injection. To better understand this phenomenon, distillation experiments were performed using seven-component synthetic oil consisting of equal weights of the following alkanes: n-C5, n-C6, n-C7, n-C8, n-C9, nC10, and n-C15. For comparison purposes, three distillation processes were investigated: dry-, steam-, and steam-propane-distillation, the latter at a propane:steam mass ratio of 0.05. The injection rate of nitrogen during dry-and steam-distillation was the same as that of propane during steam-propane distillation, 0.025 g/min, with steam injection rate kept at 0.5 g/min. The distillation temperatures ranged from 115°C to 300°C and were increased in steps of 10°C. The cell was kept at each temperature plateau (cut) for 30 minutes. Distillation pressures ranged from 0 psig for dry distillation to 998 psig for steam-and steam-propane distillation. The temperature-pressure combination used represented 15°C superheated steam conditions. Distillate samples were collected at each cut, and the volume and weight of water and hydrocarbon measured. In addition, the composition of the hydrocarbon distillate was measured using a gas chromatograph. Main results of the study may be summarized as follows. First, the hydrocarbon yield at 125°C is highest with steam-propane distillation (74 wt%) compared to steam distillation (58 wt%), and lowest with dry distillation (36 wt%). This explains in part the oil production acceleration observed in steam-propane displacement experiments. Second, the final hydrocarbon yield at 300°C however is the same for the three distillation processes. This observation is in line with the fact that oil recoveries were very similar in steam- and steam-propane displacement experiments. Third, based on the yields of individual hydrocarbon components, steam-propane distillation lowers the apparent boiling points of the hydrocarbons significantly. This phenomenon may be the most fundamental effect of propane on hydrocarbon distillation, which results in a higher yield during steam-propane distillation and oil production acceleration during steam-propane displacement. Fourth, experimental K-values are higher in distillations with steam-propane for the components n-hexane, n-heptane, n-octane, and n-nonane. Fifth, vapor fugacity coefficients for each component are higher in distillations with steam-propane than with steam. Finally, Gibbs excess energy is overall lower in distillations with steam-propane than with steam. The experimental results clearly indicate the importance of distillation on oil recovery during steam-or steam-propane injection. The experimental procedure and method of analysis developed in this study (for synthetic oil) will be beneficial to future researchers in understanding the effect of propane as steam additive on actual crude oils.

Ramirez Garnica, Marco Antonio

2003-05-01T23:59:59.000Z

6

MEMORANDUM OWNER(S)  

Office of Legacy Management (LM)

OWNER(S) OWNER(S) -------- past : Lb-J ' 0-c @+a+~-~% current: -- ________________________ ------7--- -- Owner cantacted 0 yes 4t no; if yes, date contacted TYPE OF OPERATION ----------------- q Research & Development 0 Facility Type 0 Production scale testing 0 Manufacturing 0 Pilat Scale 0 Bench Scale Process i Theoretical Studies Sample & Analysis 0 Production 0 Di5posal/Storage TYPE OF CONTRACT ----_----------- 0 Prime q Subcontractor Cl Purchase Order 0 University 0 Research Organization 0 Government Spohscred Facility 0 Other --------------------- . 0 Other information (i.e., cost + fixed fee, unit price, time 84 material, e,tc:) ------- 'Canfract/Purchase Order # --. CONTRACTING PERIOD: r4J~--___-----___---_____________ ----- OWNERSHIP:

7

Experimental and analytical studies of hydrocarbon yields under dry-, steam-, and steam-with-propane distillation  

E-Print Network (OSTI)

Simulation study has shown oil production is accelerated when propane is used as an additive during steam injection. To better understand this phenomenon, distillation experiments were performed using San Ardo crude oil (12oAPI). For comparison purposes, three distillation processes were investigated: dry-, steam-, and steam-propanedistillation, the latter at the propane-to-steam mass ratio of 0.05 at steam injection rate 0.5 g/min. Two sets of the distillation experiments were carried out. In the first set of experiments, the distillation temperatures ranged from 115ºC to 300ºC. Distillation pressures ranged from 0 psig to 998 psig for steam- and steam-propane distillation. The temperature-pressure combination used represented 15ºC superheated steam conditions. In the second set of experiments, the distillation temperatures ranged from 220oC to 300oC at 260 psig. The temperature pressure combination used represented field conditions for crude oil. For both conditions, the cell was kept at each temperature plateau (cut) until no increase occurs in distillation yields. Distillation yields were collected at each cut, and the volume and weight of water and hydrocarbon measured. Based on these experiments, a thermodynamic modeling framework was developed that describes distillation effect and oil production for steam distillation experiments. The model is based on composition of crude oil, molecular weight of heavy fraction. The analytical model results are compared against the experimental data for synthetic crude and crude oil to verify the validity of the model. Main results of the study may be summarized as follows. The yields for steam distillation for saturated conditions of Tsat+15 o C and Psat is 10 % and with addition of 5% of propane to steam no significant increase occurs in distillation yields. The yields for steam distillation for field conditions of 260 psig and temperature range (220 ~300oC) is 18 % and with addition of 5% of propane to steam no significant increase in distillation yields. The results indicate that propane has minimal distillation effect on the heavy oil. This occurs possibly because of lesser amount of light fractions in the heavy oil that enhance the separation of components in the oil caused by the concentration gradient.

Jaiswal, Namit

2003-05-01T23:59:59.000Z

8

OWNER(S) Past:  

Office of Legacy Management (LM)

--------------__ --------------__ CITY: ' -* -I c.l.&&!,Ck -------------------------- OWNER(S) ------__ Past: Owner contacted q yes current: -------------------------- if yea, date contacted ------_---___ TYPE OF OPERATION --------~~_~----_ q Research & Development 0 Production scale testing 0 Pilot Scale 0 Bench Scale Process,. 0 Theoretical Studies 0 Sample & Analysis 0 Production 0 Disposal/Storage 0 Facility Type a Manufacturing (I University, 0 Research Organization 0 Government Sponsored Facility 0 Other ~~~--~~~---~~~------_ TYPE OF CONTRACT ---_---__------_ 0 Prinie 0 Subcantractbr 0 Purchase Order 0 Other information (i.e., cast + fixed fee, unit price, time b material, qtc) ----'w-- ~~--~~-~~~----~~----________ Contract/Purchase ' Order

9

SUBJECT: OWNER(S)  

Office of Legacy Management (LM)

HEHORANDUH HEHORANDUH ;;&; DC&b ------w--v SUBJECT: OWNER(S) -------- P1st a Owner contrctmd TYPE OF OPERATION ----------------- 0 Research I Development 0 Facility Type 0 Production scale testing 0 Pilot Scrlr 0 Bench Seal0 Procemm 0 Theoretical Studier 0 Sample & Anrlyri l 0 Production x Dimpomrl/Storrgr 0 Hmufrcturing 0 University 0 Rmsmarch Organization 0 Government Sponmored Facility 0 Other -II---------------- TYPE OF CONTRACT ----u---------- 0 d ime Subcontract& 0 Purchrre Order 0 Other information (i.e., comt -w-e--- Contrrct/Purchrsa Order 0 CONTRACTING PERIOD: ------------------ . OWNERSHIPa AEC/HED OWNED m---w LANDS 0 BUILDINSS 0 EQUIPMENT 0 ORE OR RAW HA-I-L 0 FINAL PRODUCT q WASTE & RESIDUE 0 AEC/HED LEASED ---w-w E 0 0

10

OWNER(S)  

Office of Legacy Management (LM)

l . . l . . ; * 3Tb'-j .I OWNER(S) rf yea, date contacted ___ TYPE OF OPERATION --~~----~---__--_ aResearch & Development q Facility Type 0 Production scale testing Et Pilot Scale q Hanufacturing 0 Bench Scale Process 0 University 0 Theoretical Studies 0 Research Organization Cl 0 Government Sponsored Facility Sample SC Analysis Cl Other --------__----___--_ 3 Production 1 Disposal/Storage TYPE OF CONTRACT --~_---__---____ m.p rime SC5 sLta4rM-J / Cl Subcqntractor 0 Purchase Order 0 Other information (i.e., cost + fixed fee, unit price? Contract/Purchase Order # ~~~ti~ --------------------_____________ AECf MED OWNED -_--_ LANDS BUILDINGS ' EQUIPMENT ORE OR RAW MATL [3 FINAL PRODUCT 0 WASTE & RESIDUE q GOVT OWNED ----- GOUT LEASED -----_ E

11

OWNER(S)  

Office of Legacy Management (LM)

_----- _----- past: %J +c - fl*+;o.rrq -____------------- Owner contacted 0 yes Curr@nt: ______ -----------L-----l- if yes, date contacted TYPE OF OPERATION Reeearch & Development 0 Facility Type 0 Production scale testing Cl Pilot Scale 0 Bench Scale Process 0 0 Research Organization Theoretical Studies 0 0 Government Sponsored Facility ~ ~*a;~a.a~~plysis 0 Other ~~~~~~~~------____--- 0 Production 0 DispdsalfStoraqe TYPE OF CONTRACT ---------------- 0 Prime 0 Subcontractor 0 Purchase Order 0 Other information (i.e., cost + fixed fee, unit price, time & mater!&, etc) ------- --------------------LA------ ~~------------~~~-~--------- Contract/Purchase Order # ~-----~-~~~~~~~--~~~_____________ CONTRACTING PERIOD: f?Ar! lts' d' ------------------ ___-_ +----a-

12

OWNER(S)  

Office of Legacy Management (LM)

------ - ------ - Past: ~~~-~~~-~~~~~~~~~~rrent: Owner contacted q yes tina;-. ____ c-lti&pJ-~ lf yes, date contacted -_---__---___ TYPE OF OPERATION -_-----_--_--____ q Research & Development 0 Production scale testing 0 Pilot Scale 0 Bench Scale Process : 'Theoretical Studier Sample & Analysis G Production 0 Disposal/Storage TYPE OF CONTRACT ~-~~~----~~----_ &, Facility Type q Manufacturing 0 University a Research Organizaticn a Other information (i.e., cost + fixed fee,, unit price, -_---- yryoi -37 J-1 4:~zL~~:~:q~&- ,-antract,purchase Order # ,L,U,-37-?\- ---------------------------- --------------------_____________ my~mx~~ai_~Gi~~~Q : _I 7 v 3 _ I 9 V-Y, ---_--_------------------------------ OWNERSHIP: AEC/MED AEC/MED GOUT GOUT

13

SiC Fiber Strengths after Oxidation in Wet and Dry Air, Steam, and ...  

Science Conference Proceedings (OSTI)

Abstract Scope, Data for SiC fiber strengths after oxidation in wet and dry air, steam, and low pO2 are reviewed. Oxidation and scale crystallization kinetics are  ...

14

Type A: Magma-heated, Dry Steam Resource | Open Energy Information  

Open Energy Info (EERE)

source source History View New Pages Recent Changes All Special Pages Semantic Search/Querying Get Involved Help Apps Datasets Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon » Type A: Magma-heated, Dry Steam Resource Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Type A: Magma-heated, Dry Steam Resource Dictionary.png Type A: Magma-heated, Dry Steam Resource: No definition has been provided for this term. Add a Definition Brophy Occurrence Models This classification scheme was developed by Brophy, as reported in Updating the Classification of Geothermal Resources.[1] Type A: Magma-heated, Dry Steam Resource Type B: Andesitic Volcanic Resource Type C: Caldera Resource Type D: Sedimentary-hosted, Volcanic-related Resource Type E: Extensional Tectonic, Fault-Controlled Resource

15

Steam Quality  

E-Print Network (OSTI)

"STEAM QUALITY has been generally defined as the amount of moisture/vapor (or lack thereof) contained within steam produced from some form of boiler. It has long been used as the standard term for the measurement of ""wet or dry"" steam and as a means of measuring enthalpy. Totally dry steam is said to be ""saturated"" steam. It is sometimes defined as the ""dryness faction"". The term in its historical denotation refers to a physical attribute of the steam. That attribute being ""what is the percentage water vapor content of the steam"" as compared to the amount of steam. Dry saturated steam is steam which carries no water vapor with it and is defined as having a quality of 1.00 (100%). Since water vapor is always present at the interface between the water level and the steam in a boiler, some water vapor will always tend to pass through the system with the steam. Hence, a continuing problem. If steam does carry water vapor past the separators it will tend to coalesce as a liquid, and in doing so it also will carry boiler chemicals with it."

Johnston, W.

1989-09-01T23:59:59.000Z

16

Geothermal Steam Power Plant | Open Energy Information  

Open Energy Info (EERE)

(Redirected from Dry Steam) (Redirected from Dry Steam) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home General List of Dry Steam Plants List of Flash Steam Plants Steam Power Plants Dry Steam Power Plants Simple Dry Steam Powerplant process description - DOE EERE 2012 Dry steam plants use hydrothermal fluids that are primarily steam. The steam travels directly to a turbine, which drives a generator that produces electricity. The steam eliminates the need to burn fossil fuels to run the turbine (also eliminating the need to transport and store fuels). These plants emit only excess steam and very minor amounts of gases.[1] Dry steam power plants systems were the first type of geothermal power generation plants built (they were first used at Lardarello in Italy in 1904). Steam technology is still effective today at currently in use at The

17

Combined cycle electric power plant having a control system which enables dry steam generator operation during gas turbine operation  

SciTech Connect

A control system for a combined cycle electric power plant is described. It contains: at least one gas turbine including an exit through which heated exhaust gases pass; means for generating steam coupled to said gas turbine exit for transferring heat from the exhaust gases to a fluid passing through the steam generator; a steam turbine coupled to the steam generator and driven by the steam supplied thereby; means for generating electric power by the driving power of the turbines; condenser means for receiving and converting the spent steam from the steam turbine into condensate; and steam generating means comprising a low pressure storage tank, a first heat exchange tube, a boiler feedwater pump for directing fluid from a low pressure storage tank through the first heat exchange tube, a main storage drum, a second heat exchange tube, and a high pressure recirculation pump for directing fluid from the main storage pump through the second heat exchange tube. The control system monitors the temperature of the exhaust gas turbine gases as directed to the steam generator and deactuates the steam turbine when a predetermined temperature is exceeded.

Martz, L.F.; Plotnick, R.J.

1974-08-08T23:59:59.000Z

18

Combined thermal storage pond and dry cooling tower waste heat rejection system for solar-thermal steam-electric power plants. Final report  

DOE Green Energy (OSTI)

The thermal performance and economics of the combined thermal storage pond and dry cooling tower waste heat rejection system concept for solar-thermal steam-electric plants have been evaluated. Based on the computer simulation of the operation of southwest-sited solar-thermal plants, it has been determined that the combined pond-tower concept has significant cost and performance advantages over conventional dry cooling systems. Use of a thermal storage pond as a component of the dry cooling system allows a significant reduction in the required dry cooling heat exchange capacity and the associated parasitic power consumption. Importantly, it has been concluded that the combined pond-tower dry cooling system concept can be employed to economically maintain steam condensing temperatures at levels normally achieved with conventional evaporative cooling systems. An evaluation of alternative thermal storage pond design concepts has revealed that a stratified vertical-flow cut-and-fill reservoir with conventional membrane lining and covering would yield the best overall system performance at the least cost.

Guyer, E.C.; Bourne, J.G.; Brownell, D.L.; Rose, R.M.

1979-02-28T23:59:59.000Z

19

TO: FILE MEMORANDUM SUBJECT: ALTERNATE OWNER(S)  

Office of Legacy Management (LM)

SUBJECT: SUBJECT: ALTERNATE OWNER(S) -__----- Owner csntacted r~ yes current: --------------------A----- if yes, date contacted TYPE OF OPERATION ------------_____ Research & Development 0 Facility Type 0 Production seal e testing 0 Pilot Scale 0 Bench Scale Process i Theoretical Studi es Sample & Analysis Producti on Di spas.31 /Storage a' Manufacturing q University 0 Research Organization 0 Government Sponsored Facility Cl Other ~~~~~~~----~~-------- 0 0 Prime q Other information (i.e., cast 0 Subcontractor 0 'Purchase Order + fixed fee, unit piice, pi time & material, gtc) ~~-----_------~~_-------~-~- .Contract./Purchaee Order # fi~k~ti;3 -----------_---------------- CONTRACTING PEXIOD: tit-k ------------------ would -------------------------------------

20

User_OrgOwner_Overview  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Organization Owner Overview Organization Owner Overview © 2011 SuccessFactors, Inc. - 1 - SuccessFactors Learning Confidential. All rights reserved. Job Aid: Organization Owner Overview Purpose The purpose of this job aid is to guide organization owners through the step-by-step process of available features within SuccessFactors Learning. The organization dashboard is a collection of charts and data tables that summarize learning data for your organizations and sub-organizations. Note: Depending on how permissions were configured in, access to the following features will vary for each organization. Task A. Organization Dashboard From the Home page, roll-over the Organization tab and select Dashboard from the list. 1 1 Succession Planner 7 Steps

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Geothermal Steam Power Plant | Open Energy Information  

Open Energy Info (EERE)

Jump to: navigation, search Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home General List of Dry Steam Plants List of Flash Steam Plants Steam Power Plants Dry Steam Power Plants Simple Dry Steam Powerplant process description - DOE EERE 2012 Dry steam plants use hydrothermal fluids that are primarily steam. The steam travels directly to a turbine, which drives a generator that produces electricity. The steam eliminates the need to burn fossil fuels to run the turbine (also eliminating the need to transport and store fuels). These plants emit only excess steam and very minor amounts of gases.[1] Dry steam power plants systems were the first type of geothermal power generation plants built (they were first used at Lardarello in Italy in 1904). Steam technology is still effective today at currently in use at The

22

Casablanca Carlos American Electric Power Transmission Owner  

E-Print Network (OSTI)

(Facilitator) Chantal PJM Interconnection Not Applicable Horstmann John Dayton Power & Light Company (The) Transmission Owner Issermoyer John PPL Electric Utilities Corp. dba PPL Utilities Transmission Owner

Pjm Interconnection Llc; Teleconference Webex Participants; Firstenergy Solutions; Corp Transmission Owner; Boltz Jeff; Firstenergy Solutions; Corp Transmission Owner; Fecho Thomas; Indiana Michigan; Power Company; Transmission Owner; Patten Kevin; Company Transmission Owner

2012-01-01T23:59:59.000Z

23

Owners of nuclear power plants  

Science Conference Proceedings (OSTI)

Commercial nuclear power plants in this country can be owned by a number of separate entities, each with varying ownership proportions. Each of these owners may, in turn, have a parent/subsidiary relationship to other companies. In addition, the operator of the plant may be a different entity as well. This report provides a compilation on the owners/operators for all commercial power reactors in the United States. While the utility industry is currently experiencing changes in organizational structure which may affect nuclear plant ownership, the data in this report is current as of July 1996. The report is divided into sections representing different aspects of nuclear plant ownership.

Hudson, C.R.; White, V.S.

1996-11-01T23:59:59.000Z

24

Steam in Distribution and Use: Steam Quality Redefined  

E-Print Network (OSTI)

Steam quality is an important measurement in steam generation. It's a measurement of steam to moisture ratio. In use, steam quality takes on a different meaning- steam which maximizes energy transfer. To do this, the steam must be clean, dry, of desired pressure and free of air and non-condensible gases. Objectives in these areas should be set and an action plan implemented. Typical objectives could be to specify steam pressure delivery of maximum pressure and to use steam at the lowest pressure possible. Steam velocity ranges and maximum system pressure drops should be set. Cleaning steam and protecting control devices is an important means of maintaining quality. Draining condensate and venting air and other gases preserves the steam quality at the point of use. Poor pressure control yields poor operation and efficiency. Dirty steam causes valve leaks and maintenance problems. Improper drainage and venting can cause premature corrosion and poor heat transfer.

Deacon, W. T.

1989-09-01T23:59:59.000Z

25

Steam in Distribution and Use: Steam Quality Redefined  

E-Print Network (OSTI)

"Steam quality is an important measurement in steam generation. It's a measurement of steam to moisture ratio. In use, steam quality takes on a different meaning - steam which maximizes energy transfer. To do this, the steam must be clean, dry, of desired pressure and free of air and non-condensable gases. Objectives in these areas should be set and an action plan implemented. Typical objectives could be to specify steam pressure delivery of maximum pressure and to use steam at the lowest pressure possible. Steam velocity ranges and maximum system pressure drops should be set. Cleaning steam and protecting control devices is an important means of maintaining quality. Draining condensate and venting air and other gases preserves the steam quality at the point of use. Poor pressure control yields poor operation and efficiency. Dirty steam causes valve leaks and maintenance problems. Improper drainage and venting can cause premature corrosion and poor heat transfer."

Deacon, W.

1989-09-01T23:59:59.000Z

26

Buildings Performance Database Helps Building Owners, Investors...  

NLE Websites -- All DOE Office Websites (Extended Search)

Buildings Performance Database Helps Building Owners, Investors Evaluate Energy Efficient Buildings Buildings Performance Database June 2013 A new database of building features and...

27

Property:Owners | Open Energy Information  

Open Energy Info (EERE)

Owners Owners Jump to: navigation, search Property Name Owners Property Type Page Description A unique list of owners of all power plants in the area. Automatically populated using ask query on Property: Owner of Category: Energy Generation Facility with property InGeothermalResourceArea set to the the variable vName of the Geothermal Resource Area Subproperties This property has the following 301 subproperties: A Abraham Hot Springs Geothermal Area Adak Geothermal Area Akun Strait Geothermal Area Akutan Fumaroles Geothermal Area Alum Geothermal Area Alvord Hot Springs Geothermal Area Arrowhead Hot Springs Geothermal Area Ashton Warm Springs Geothermal Area Astor Pass Geothermal Area Augusta Mountains Geothermal Area B Bailey Bay Hot Springs Geothermal Area Baker Hot Spring Geothermal Area

28

Steam Generator Reference Book, Revision 1: Volume 1  

Science Conference Proceedings (OSTI)

The Steam Generator Reference Book documents the state of the art in PWR steam generator technology, providing a comprehensive source for operators, owners, and designers of PWR nuclear power plants. The book summarizes pertinent steam generator operating issues and provides recommendations to improve operational efficiency. Information in the book represents 15 years of research and development activity over the course of several hundred research projects involving PWR steam generator issues.

1994-12-31T23:59:59.000Z

29

Definition: Generator Owner | Open Energy Information  

Open Energy Info (EERE)

Generator Owner Entity that owns and maintains generating units.1 References Glossary of Terms Used in Reliability Standards An LikeLike UnlikeLike You like this.Sign Up...

30

Flash Steam Power Plant | Open Energy Information  

Open Energy Info (EERE)

Flash Steam Power Plant Flash Steam Power Plant (Redirected from Flash Steam Power Plants) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Flash Steam Power Plants General List of Flash Steam Plants Flash Steam power plant process diagram - DOE EERE 2012 Flash steam plants are the most common type of geothermal power generation plants in operation in the world today. Fluid at temperatures greater than 360°F (182°C) is pumped under high pressure into a tank at the surface held at a much lower pressure, causing some of the fluid to rapidly vaporize, or "flash." The vapor then drives a turbine, which drives a generator. If any liquid remains in the tank, it can be flashed again in a second tank to extract even more energy.[1] Facility Name Owner Capacity (MW) Facility

31

JOBAID-ORGANZIATION OWNER OVERVIEW | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

OWNER OVERVIEW JOBAID-ORGANZIATION OWNER OVERVIEW The purpose of this job aid is to guide organization owners through the step-by-step process of available features within...

32

Energy Efficiency: Helping Home Owners and Businesses Understand...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficiency: Helping Home Owners and Businesses Understand Energy Usage Energy Efficiency: Helping Home Owners and Businesses Understand Energy Usage November 7, 2013 - 3:55pm...

33

Dry Granulation of Molten Blast Furnace Slag and Heat Recovery ...  

Science Conference Proceedings (OSTI)

Meeting the Materials Challenges to Enable Clean Coal Technologies ... Study on Drying Characteristics of Australian Brown Coal Using Superheated Steam.

34

Flash Steam Power Plant | Open Energy Information  

Open Energy Info (EERE)

Flash Steam Power Plant Flash Steam Power Plant Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Flash Steam Power Plants General List of Flash Steam Plants Flash Steam power plant process diagram - DOE EERE 2012 Flash steam plants are the most common type of geothermal power generation plants in operation in the world today. Fluid at temperatures greater than 360°F (182°C) is pumped under high pressure into a tank at the surface held at a much lower pressure, causing some of the fluid to rapidly vaporize, or "flash." The vapor then drives a turbine, which drives a generator. If any liquid remains in the tank, it can be flashed again in a second tank to extract even more energy.[1] Facility Name Owner Capacity (MW) Facility Type Commercial Online Date Geothermal Area

35

Steam compression with inner evaporative spray cooling: a case study  

Science Conference Proceedings (OSTI)

An adiabatic dry saturated steam compression process with inner evaporative spray cooling in screw compressors for steam heat pump systems is studied. Thermodynamic model and simulation of this variable-mass compression process are devised. Differential ... Keywords: inner evaporative spray cooling, screw compressors, simulation, steam compression, steam heat pumps, thermodynamic modelling, variable-mass compression, water injection

Jian Qui; Zhaolin Gu; Guoguang Cai

2004-12-01T23:59:59.000Z

36

FM12 & rus Steam - Steam Users' Forums  

U.S. Energy Information Administration (EIA)

STORE COMMUNITY ABOUT SUPPORT Steam Users' Forums > Steam Game Discussions > D - G > Football Manager series

37

Danish Wind Turbine Owners Association | Open Energy Information  

Open Energy Info (EERE)

Owners Association Owners Association Jump to: navigation, search Name Danish Wind Turbine Owners' Association Place Aarhus C, Denmark Zip DK-8000 Sector Wind energy Product Danish Wind Turbine Ownersâ€(tm) Association is a non-profit, independent association overseeing wind turbine ownersâ€(tm) mutual interests regarding the authorities, political decision-makers, utilities and wind turbine manufacturers. References Danish Wind Turbine Owners' Association[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Danish Wind Turbine Owners' Association is a company located in Aarhus C, Denmark . References ↑ "Danish Wind Turbine Owners' Association" Retrieved from "http://en.openei.org/w/index.php?title=Danish_Wind_Turbine_Owners_Association&oldid=344068

38

Waste heat steams ahead with injection technology  

Science Conference Proceedings (OSTI)

Owners of Commercial-Industrial-Institutional buildings whose thermal usage is too variable to implement cogeneration are looking to a gasturbine steam-injection technology, called the Cheng Cycle, to reduce their energy costs. The Cheng Cycle uses industrial components-a gas-turbine generating set, a waste-heat recovery steam generator and system controls-in a thermodynamically optimized mode. In the process, steam produced from waste heat can be used for space or process heating or to increase the electrical output of a gas turbine. The process was patented in 1974 by Dr. Dah Yu Cheng, of the University of Santa Clara, Santa Clara, Calif. When a plant's thermal needs fall because of production or temperature changes, unused steam is directed back to the turbine to increase electrical output. As thermal requirements rise, the process is reversed and needed steam is channeled to plant uses.

Shepherd, S.; Koloseus, C.

1985-03-01T23:59:59.000Z

39

Steam Pricing  

E-Print Network (OSTI)

Steam is used in many plants to furnish both heat and mechanical energy. It is typically produced in several fired boilers which may operate at different pressures and with different efficiencies. It is then distributed throughout the plant to the various users in steam distribution systems, each one operating at a different pressure and temperature. This paper examines various ways to cost steam and discusses the importance of proper costing. Specifically it addresses three types of steam costs; Marginal Costs, Project Evaluation Costs and Financial Costs.

Jones, K. C.

1986-06-01T23:59:59.000Z

40

Significant Silica Solubility in Geothermal Steam  

DOE Green Energy (OSTI)

Although it is widely believed that silica solubility in low pressure (5 to 10 bar) geothermal steam is negligible, when one takes into account steam flows exceeding 10 million tonnes a year--at Wairakei, for instance--it is found that the amount transmitted in the vapor has the potential to give significant deposits on turbine nozzles and blades. A 150 MWe power station, when based on flows from a hot water reservoir at (a) 250 C or (b) 315 C, and with separator pressures of 6 bar, is found to carry about 100 and 200 kg/year respectively in the steam phase. In the case of a similar sized station exploiting a dry steam reservoir such as The Geysers, equivalent silica flows are obtained, dissolved in steam and carried as dust--the latter as solid particles precipitating from the vapor en route from source to turbine, and not preexisting in the formations as is commonly considered. Choking or coating of subterranean rock near such dry steam wells due to exsolving silica, may be the principal cause of declining steam discharge under production. Silica from completely dry or superheated steam can also seal the cap and sides of steam reservoirs when expanding below the criticus temperature (236 C) in a way previously thought possible only by hot water or wet steam.

James, Russell

1986-01-21T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

TO: FILE GiR FROM: SUBJECT: I OWNER(S) Past: Current:  

Office of Legacy Management (LM)

3 749 3 749 '*,. .,;L ----.-. _ 5' . iMEMORANDUM TO: FILE GiR FROM: , SUBJECT: I OWNER(S) ------__ Past: ------------------_----~ Current: Owner contacted q yes qnnc; ~~-~~~---------~~--_______ if yes, date contacted 1 ! I TYPE OF OPERATION --~_--___~---_--_ $ Research b Development a Facility Type 1 I 0 Production scale testing 0 Pilot Scale Bench Scale Process Theoretical 'Studies 0 Sample & Analysis G Production E Disposal/Storage 0 Research 0 Uther --------------T------ I T'/PE OF CONTRACT -----------_____ 0 Prime I2 C! Subcontractor Other information (i.e.:, cost q Purchase Order + fixed fee, unit Arice, time 84 material, etr) i ------- 'I ----------------------i__--_ Contract/Purchase Qrdei. W -----------I--k---j----- ~PJKJbL-I @J OWNERSHIP:

42

Thomas Reddinger Director, Steam  

E-Print Network (OSTI)

(Distribution) Deborah Moorhead Office Coordinator III Martin Bower Steam Plant Operator Richard Redfield SteamThomas Reddinger Director, Steam Operations Steven Richards Assistant Manager of Maintenance Plant Operator Bohdan Sawa Steam Plant Operator Robert Tedesco Steam Plant Operator James Bradley

Raina, Ramesh

43

PP-82-3 The Joint Owners of the Highgate Interconnection Facilities...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3 The Joint Owners of the Highgate Interconnection Facilities PP-82-3 The Joint Owners of the Highgate Interconnection Facilities Presidential Permit authorizing The Joint Owners...

44

Property:Owner | Open Energy Information  

Open Energy Info (EERE)

property of type Page. property of type Page. Subproperties This property has the following 1 subproperty: G GRR/Section 4-FD-a - Exploration Permit BLM Pages using the property "Owner" Showing 25 pages using this property. (previous 25) (next 25) A AB Tehachapi Wind Farm + Coram Energy + AFCEE MMR Turbines + AFCEE + AG Land 1 + AG Land Energy LLC + AG Land 2 + AG Land Energy LLC + AG Land 3 + AG Land Energy LLC + AG Land 4 + AG Land Energy LLC + AG Land 5 + AG Land Energy LLC + AG Land 6 + AG Land Energy LLC + AVTEC + AVTEC + Aberdeen Biomass Facility + Sierra Pacific Industries + Adair Wind Farm I + Shafer Systems + Adair Wind Farm II + MidAmerican Energy + Aero Turbine + AeroTurbine Energy Company + Aeroman Repower Wind Farm + Coram Energy + Affinity Wind Farm + Affinity Wind LLC +

45

Steam purity in PWRs  

Science Conference Proceedings (OSTI)

Reports that 2 EPRI studies of PWRs prove that impure steam triggers decay of turbine metals. Reveals that EPRI is attempting to improve steam monitoring and analysis, which are key steps on the way to deciding the most cost-effective degree of steam purity, and to upgrade demineralizing systems, which can then reliably maintain that degree of purity. Points out that 90% of all cracks in turbine disks have occurred at the dry-to-wet transition zone, dubbed the Wilson line. Explains that because even very clean water contains traces of chemical impurities with concentrations in the parts-per-billion range, Crystal River-3's secondary loop was designed with even more purification capability; a deaerator to remove oxygen and prevent oxidation of system metals, and full-flow resin beds to demineralize 100% of the secondary-loop water from the condenser. Concludes that focusing attention on steam and water chemistry can ward off cracking and sludge problems caused by corrosion.

Hopkinson, J.; Passell, T.

1982-10-01T23:59:59.000Z

46

Steam Turbine Casing and Valve Body Repair Guidelines  

Science Conference Proceedings (OSTI)

Today’s flexible mode of operation can result in damage to heavy-section components, such as steam turbine and valve casings. Thus, owners and operators are often faced with repairing a critical component. This report is part of a set of documents that address the key areas in the asset management of steam turbine casings and valve bodies—nondestructive evaluation and damage detection, repair, and life ...

2013-12-14T23:59:59.000Z

47

Field Guide: Heat Recovery Steam Generator Tube Failure  

Science Conference Proceedings (OSTI)

In conventional and combined-cycle plants, boiler and heat recovery steam generator (HRSG) tube failures have been the main availability problem for as long as reliable statistics have been kept for each generating source. The three volumes of the Electric Power Research Institute (EPRI) report Boiler and Heat Recovery Steam Generator Tube Failures: Theory and Practice (1012757) present an in-depth description of the various HRSG and degradation mechanisms, providing plant owners and operators with the t...

2010-12-15T23:59:59.000Z

48

Realities of Chiller Plant Operation: Utility Impacts on Owner...  

NLE Websites -- All DOE Office Websites (Extended Search)

plant operating costs. The building owner, another engineering consultant, and the local utility representatives were confused by the rates and missed an opportunity to cut...

49

Rights and Duties of Mines and Mine Owners, General (Missouri)  

Energy.gov (U.S. Department of Energy (DOE))

This legislation addresses general operational guidelines for mine owners regarding public notices, fees, land and mineral ownership, requirements for mining in certain municipalities, and mining...

50

Visiting With Santa Fe Small Business Owners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Visiting With Santa Fe Small Business Owners Visiting With Santa Fe Small Business Owners Visiting With Santa Fe Small Business Owners May 10, 2012 - 9:02am Addthis Dot Harris Dot Harris The Honorable Dot Harris, Director, Office of Economic Impact and Diversity You've got to do your homework in order to contract with the federal government. Whether you are a large or small business owner, learning the ins and outs of government contracting takes dedication, perseverance, and taking advantage of opportunities to meet face-to-face with procurement experts and other businesses. That's where our Small Business Roundtables, Business Opportunity Sessions, conference booths, and Regional Small Business Summits come in. We want to meet directly with small business owners, managers, and staffers, to hear what you need to learn from us to make the contracting

51

Tips for Renters and Property Owners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips for Renters and Property Owners Tips for Renters and Property Owners Tips for Renters and Property Owners July 5, 2012 - 4:51pm Addthis Tips for Renters and Property Owners If you rent, or if you own a rental unit, you can use many of the tips throughout this guide to save money and energy. Renters You can reduce your utility bills by following the tips in these sections: Lighting Heating and Cooling (if you control the thermostat) Appliances Home Office and Home Electronics Windows Transportation Encourage your landlord to follow these tips as well. They'll save energy and money, improving your comfort and lowering your utility bills even more. Property Owners Nearly all of the information in this guide applies to rental units. The section on Your Home's Energy Use focuses on air leaks, insulation, heating

52

Steam-flooding  

SciTech Connect

Steam-flooding has become an established recovery technique within the last 20 years. This overview discusses its evolution, methods for selecting and designing steam-floods, constraints, and possible improvements. The term steam-flooding is used here in a general sense. The discussion includes steam soak (cyclic steam injection) and steam drive.

Matthews, C.S.

1983-03-01T23:59:59.000Z

53

Steam-channel-expanding steam form drive  

SciTech Connect

In a viscous oil reservoir in which the stratification of the rock permeability is insufficient to confine steam within the most permeable strata, oil can be produced by forming and expanding a steam channel through which steam is flowed and oil is produced. Steam is injected and fluid is produced at rates causing a steam channel to be extended between locations that are horizontally separated. A foam-forming mixture of steam, noncondensable gas and surfactant is then injected into the steam channel to provide foam and a relatively high pressure gradient within the channel, without plugging the channel. A flow of steam-containing fluid through the steam channel is continued in a manner such that the magnitudes of the pressure gradient, the rate of oil production, and the rate of steam channel expansion exceed those which could be provided by steam alone. 10 claims, 6 figures.

Dilgren, R.E.; Hirasaki, G.J.; Hill, H.J.; Whitten, D.G.

1978-05-02T23:59:59.000Z

54

CIBO's Energy Efficiency Handbook for Steam Power Systems  

E-Print Network (OSTI)

The Council of Industrial Boiler Owners (CIBO) has developed a handbook to help boiler operators get the best performance from their industrial steam systems. This energy efficiency handbook takes a comprehensive look at the boiler and steam system and addresses opportunities to improve performance every step of the way, including boiler maintenance, optimization, benchmarking, water treatment, and energy efficiency services. The handbook will include a checklist of items that operators should look for to improve their steam system's performance. This IETC paper will introduce the new CIBO handbook and describe its contents. The paper will also explain how the handbook is intended to be used.

Bessette, R. D.

1997-04-01T23:59:59.000Z

55

The steam generator changeout at Beznau-1  

Science Conference Proceedings (OSTI)

At the Beznau-1 nuclear power plant in Switzerland, the unit's two steam generators were replaced in the second quarter of 1993. The steam generator replacement portion of the outage - the period from when contractors were given access to the containment to when the steam generators were ready for hydrostatic pressure testing - was 44 days (April 12- May 26, 1993), shorter than the 46 days gained. Total length of the outage was 99 days (April 2 - July 9). Collective radiation dose received by project personnel was 110 person-rem, much less than the planned 250 person-rem. Project cost was about $50 million, including the new SGs and the replacement work, according to Nordostschweizerische Kraftwerke AG (NOK), plant owner and operator.

Not Available

1993-11-01T23:59:59.000Z

56

Microsoft Word - 2.9 Chemical Owners 0913.docx  

NLE Websites -- All DOE Office Websites (Extended Search)

Chemical Owners Chemical Owners AFRD Line Management personnel who authorize the use of chemicals in their group's work retain responsibility for ensuring that the chemicals are properly inventoried, labeled, stored, used, and disposed. They may choose to remain Chemical Owners as described in the LBNL Chemical Hygiene and Safety Plan and manage the chemicals themselves, or delegate chemical management tasks to appropriately trained AFRD or matrixed personnel who have knowledge of the chemicals' hazards, controls, and procedures for using and storing them safely. The chemical inventory for each AFRD work area must be maintained on the Chemical Management System. When chemical management tasks are delegated, the AFRD Line Management personnel must also

57

Drying of fiber webs  

DOE Patents (OSTI)

A process and an apparatus for high-intensity drying of fiber webs or sheets, such as newsprint, printing and writing papers, packaging paper, and paperboard or linerboard, as they are formed on a paper machine. The invention uses direct contact between the wet fiber web or sheet and various molten heat transfer fluids, such as liquified eutectic metal alloys, to impart heat at high rates over prolonged durations, in order to achieve ambient boiling of moisture contained within the web. The molten fluid contact process causes steam vapor to emanate from the web surface, without dilution by ambient air; and it is differentiated from the evaporative drying techniques of the prior industrial art, which depend on the uses of steam-heated cylinders to supply heat to the paper web surface, and ambient air to carry away moisture, which is evaporated from the web surface. Contact between the wet fiber web and the molten fluid can be accomplished either by submersing the web within a molten bath or by coating the surface of the web with the molten media. Because of the high interfacial surface tension between the molten media and the cellulose fiber comprising the paper web, the molten media does not appreciately stick to the paper after it is dried. Steam generated from the paper web is collected and condensed without dilution by ambient air to allow heat recovery at significantly higher temperature levels than attainable in evaporative dryers.

Warren, David W. (9253 Glenoaks Blvd., Sun Valley, CA 91352)

1997-01-01T23:59:59.000Z

58

Drying of fiber webs  

DOE Patents (OSTI)

A process and an apparatus are disclosed for high-intensity drying of fiber webs or sheets, such as newsprint, printing and writing papers, packaging paper, and paperboard or linerboard, as they are formed on a paper machine. The invention uses direct contact between the wet fiber web or sheet and various molten heat transfer fluids, such as liquefied eutectic metal alloys, to impart heat at high rates over prolonged durations, in order to achieve ambient boiling of moisture contained within the web. The molten fluid contact process causes steam vapor to emanate from the web surface, without dilution by ambient air; and it is differentiated from the evaporative drying techniques of the prior industrial art, which depend on the uses of steam-heated cylinders to supply heat to the paper web surface, and ambient air to carry away moisture, which is evaporated from the web surface. Contact between the wet fiber web and the molten fluid can be accomplished either by submersing the web within a molten bath or by coating the surface of the web with the molten media. Because of the high interfacial surface tension between the molten media and the cellulose fiber comprising the paper web, the molten media does not appreciatively stick to the paper after it is dried. Steam generated from the paper web is collected and condensed without dilution by ambient air to allow heat recovery at significantly higher temperature levels than attainable in evaporative dryers. 6 figs.

Warren, D.W.

1997-04-15T23:59:59.000Z

59

Thomas Reddinger Director, Steam  

E-Print Network (OSTI)

Supervisor (Distribution) Deborah Moorhead Office Coordinator III Martin Bower Steam Plant Operator RichardThomas Reddinger Director, Steam Operations Steven Richards Assistant Manager of Maintenance Redfield Steam Plant Operator SU Steam Station/Chilled Water Plant Bohdan Sawa Steam Plant Operator Robert

McConnell, Terry

60

Report on Biomass Drying Technology  

DOE Green Energy (OSTI)

Using dry fuel provides significant benefits to combustion boilers, mainly increased boiler efficiency, lower air emissions, and improved boiler operation. The three main choices for drying biomass are rotary dryers, flash dryers, and superheated steam dryers. Which dryer is chosen for a particular application depends very much on the material characteristics of the biomass, the opportunities for integrating the process and dryer, and the environmental controls needed or already available.

Amos, W. A.

1999-01-12T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Steam System Optimization  

E-Print Network (OSTI)

Most plant steam systems are complex systems. Usually the fuel required to produce the steam represents a major expense for manufacturing facilities. By properly operating and maintaining the steam system and making minor improvements, significant savings can be realized.

Aegerter, R. A.

1998-04-01T23:59:59.000Z

62

Secretaries Chu and Donovan to Host Conference Call on Home Owners...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Donovan to Host Conference Call on Home Owners Energy-Saving Improvements Program Secretaries Chu and Donovan to Host Conference Call on Home Owners Energy-Saving Improvements...

63

SteamMaster: Steam System Analysis Software  

E-Print Network (OSTI)

As director of Oregon's Industrial Assessment Center, I have encountered many industrial steam systems during plant visits. We analyze steam systems and make recommendations to improve system efficiency. In nearly 400 industrial assessments, we have recommended 210 steam system improvements, excluding heat recovery, that would save $1.5 million/year with a 0.4-year payback. 75% of those recommendations have been implemented for $1.1 million annual savings with 0.3-year payback. Recently I have developed a tool to facilitate the process. SteamMaster is based on an Excel spreadsheet with a Visual Basic interface to simplify system modeling and analysis. SteamMaster has many features and capabilities, including energy and cost savings calculations for five steam recommendations. This presentation will demonstrate SteamMaster software applied to one or more industrial steam systems. Software will be made available on a national web site at no cost.

Wheeler, G.

2003-05-01T23:59:59.000Z

64

Business Owners: Prepare a Business Recovery Plan | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

a Business Recovery Plan a Business Recovery Plan Business Owners: Prepare a Business Recovery Plan Business Owners: Prepare a Business Recovery Plan Smart business owners develop and test a written business recovery plan to support them through disasters and help them stay in operation. Planning ahead will help your company get back to business more quickly. Consider your risks-How might a disaster affect your business operations? What natural disasters are most likely where you operate? Identify your critical business functions-What resources and personnel will you need to restore or reproduce these functions during a recovery? Assign disaster response duties to your employees. Identify critical suppliers-Identify suppliers, providers, shippers, resources, and other businesses you typically interact with and

65

Energy Efficiency: Helping Home Owners and Businesses Understand Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Efficiency: Helping Home Owners and Businesses Understand Efficiency: Helping Home Owners and Businesses Understand Energy Usage Energy Efficiency: Helping Home Owners and Businesses Understand Energy Usage November 7, 2013 - 3:55pm Addthis Building 90, an 89,000-square foot office building at Berkeley Lab, served as the commercial setting for the miscellaneous and electronic loads (MELs) study. 460 meters were placed throughout the building to serve as a representative sample of a wide range of device types. | Photo courtesy of Berkeley Lab. Building 90, an 89,000-square foot office building at Berkeley Lab, served as the commercial setting for the miscellaneous and electronic loads (MELs) study. 460 meters were placed throughout the building to serve as a representative sample of a wide range of device types. | Photo courtesy of

66

Realities of Chiller Plant Operation: Utility Impacts on Owner Operating  

NLE Websites -- All DOE Office Websites (Extended Search)

Realities of Chiller Plant Operation: Utility Impacts on Owner Operating Realities of Chiller Plant Operation: Utility Impacts on Owner Operating Costs and Societal Environmental Issues Speaker(s): Don Aumann Date: March 21, 2000 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Satkartar K. Kinney Don Aumann, a Senior Consultant from BKi in Oakland, will present an overview of two projects he completed for the electric utility industry. The first, a case study evaluation of a hybrid chiller plant in Jefferson City, Missouri, demonstrates the importance of carefully evaluating the impact of utility rate structures on plant operating costs. The building owner, another engineering consultant, and the local utility representatives were confused by the rates and missed an opportunity to cut chiller-plant operating costs by about 20%, totaling $15,000 per year. In

67

Steam effect on NOx reduction over lean NOx trap Pt–BaO/Al2O3 ...  

Science Conference Proceedings (OSTI)

Compared to dry atmosphere, steam promoted NOx reduction; however, under ... stored NOx over Pt–BaO/Al2O3 suggest that steam causes NH3 formation over ...

68

Steam driven markets  

Science Conference Proceedings (OSTI)

The market for steam equipment has been relatively level. Looking ahead, manufacturers anticipate steady market growth worldwide. Steam equipment manufacturers share a similar view of the market for next few years - upward. The steady upward climb is being attributed to a number of factors that will benefit steam turbine and heat recovery steam generator (HRSG) makers.

Anderson, J.L.

1993-02-01T23:59:59.000Z

69

Method for improving the steam splits in a multiple steam injection process using multiple steam headers  

SciTech Connect

This patent describes a method for enhancing the uniformity of steam distribution in a multiple steam injection system comprising a steam generator, a primary steam header, at least one secondary steam header, a primary steam line connecting the generator to the primary header, at lease one secondary steam line connecting the primary header to the secondary steam header, and a plurality of tertiary steam lines connecting the secondary steam header to a plurality of stem injection wells. It comprises injecting a surfactant into the primary steam line, mixing the surfactant and steam in the primary steam line sufficiently so that the surfactant and the steam enter the primary steam header as a foam, and mixing the surfactant and steam in the secondary steam lines sufficiently so that the surfactant and the steam enter the secondary steam header as a foam.

Stowe, G.R.

1991-03-19T23:59:59.000Z

70

texas well owner network More than a million private water  

E-Print Network (OSTI)

texas well owner network More than a million private water wells in Texas provide water to citi and are at a greater risk for exposure to compromised water quality. The Texas Water Resources Institute along with the Texas AgriLife Extension Service's Department of Soil and Crop Sciences and Department of Biological

71

Maintainability Implemented by Third-Party Contractor for Public Owner  

E-Print Network (OSTI)

is implementation of a computerized maintenance management system CMMS . The CMMS is a tool used to establish maintenance strategy for systems Construction manager · Conduct construction practices that do not alter by NASA, the owner. The policy directive endorses a maintenance management pro- gram capable of developing

Sheridan, Jennifer

72

Steam Path Audits on Industrial Steam Turbines  

E-Print Network (OSTI)

The electric utility industry has benefitted from steam path audits on steam turbines for several years. Benefits include the ability to identify areas of performance degradation during a turbine outage. Repair priorities can then be set in accordance with quantitative results from the steam path audit. As a result of optimized repair decisions, turbine efficiency increases, emissions decrease, and maintenance expenses decrease. These benefits can be achieved by using a computer program Encotech, Inc. developed for the utility industry to perform steam path audits. With the increased emphasis on industrial turbine efficiency, and as a result of the experience with the Destec Operating Company, Encotech is adapting the computer program to respond to the needs of the industrial steam turbine community. This paper describes the results of using the STPE computer program to conduct a steam path audit at Destec Energy's Lyondell Cogeneration power plant.

Mitchell, D. R.

1992-04-01T23:59:59.000Z

73

High performance steam development  

SciTech Connect

DOE has launched a program to make a step change in power plant to 1500 F steam, since the highest possible performance gains can be achieved in a 1500 F steam system when using a topping turbine in a back pressure steam turbine for cogeneration. A 500-hour proof-of-concept steam generator test module was designed, fabricated, and successfully tested. It has four once-through steam generator circuits. The complete HPSS (high performance steam system) was tested above 1500 F and 1500 psig for over 102 hours at full power.

Duffy, T.; Schneider, P.

1995-12-31T23:59:59.000Z

74

Steam Generator Management Program: Steam Generator Progress Report  

Science Conference Proceedings (OSTI)

Since 1985, EPRI has published the Steam Generator Progress Report (SGPR), which provides historical information on worldwide steam generator activities.

2009-10-19T23:59:59.000Z

75

Business Owners: Respond to an Energy Emergency | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Respond to an Energy Emergency Respond to an Energy Emergency Business Owners: Respond to an Energy Emergency Business Owners: Respond to an Energy Emergency Ensure your building is safe to occupy-Initially allow only essential, critical-operations staff into restricted areas. Ask your local or State health department for guidance on determining the safety of your building. Decide whether to activate backup power-If your backup generator doesn't automatically turn on during a power outage, you'll have to determine when to activate backup systems. First determine whether power is likely to be restored within 24 hours. If not, you may want to activate those systems to protect your business assets. Learn more Contact your fuel supplier-If you rely on fuel supplies for your business, vehicles, generators, and other equipment, contact your fuel

76

Business Owners: Prepare for Fuel Shortages | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Fuel Shortages Fuel Shortages Business Owners: Prepare for Fuel Shortages Business Owners: Prepare for Fuel Shortages You may need fuel for vehicles, generators, and other equipment to continue operating your business during an emergency. During a shortage, local authorities and fuel suppliers will prioritize getting fuel to key assets such as emergency operations centers, hospitals, food supply dealers, water supply plants, and telecommunication networks. Plan ahead to help make sure you have adequate supplies. Review your fuel supply contracts-Arrange priority contacts with fuel suppliers, including an out-of-region supplier, and include language for providing fuel supplies during an emergency. Can your fuel suppliers operate with no power? Do they have gravity-fed systems? What if your fuel

77

Business Owners: Prepare for Utility Disruptions | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

for Utility Disruptions for Utility Disruptions Business Owners: Prepare for Utility Disruptions Business Owners: Prepare for Utility Disruptions Have a plan in place in case a natural disaster or other hazard knocks out your business's electricity or natural gas service. Identify energy utilities-The utilities that are absolutely necessary to running your business. How might a disaster impact the availability of those utilities? Determine backup options-Contact your utility companies to discuss potential backup options, such as portable generators to provide power. Learn how and when to turn off utilities-For example, if you turn off your natural gas, a professional technician must turn it back on. Learn more Consider using backup generators-Generators can power the most important aspects of your business in an emergency. This will involve:

78

River resort owners find LPG a power behind their success  

SciTech Connect

This paper reports on a restaurant and resort which runs entirely on LPG. It has two generators converted to LPG that supply the power for the complex. Energy supplied from the propane is used in the kitchens, to drive the water pump and provide electricity for lighting and other power needs, and to heat the swimming pool. Far more importantly for the owners has been the fuel cost savings of at least 60%.

1991-01-01T23:59:59.000Z

79

Downhole steam quality measurement  

SciTech Connect

An empirical method for the remote sensing of steam quality that can be easily adapted to downhole steam quality measurements by measuring the electrical properties of two-phase flow across electrode grids at low frequencies.

Lee, David O. (Albuquerque, NM); Montoya, Paul C. (Albuquerque, NM); Muir, James F. (Albuquerque, NM); Wayland, Jr., J. Robert (Albuquerque, NM)

1987-01-01T23:59:59.000Z

80

Steam Digest 2001  

SciTech Connect

Steam Digest 2001 chronicles BestPractices Program's contributions to the industrial trade press for 2001, and presents articles that cover technical, financial and managerial aspects of steam optimization.

2002-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Downhole steam quality measurement  

DOE Patents (OSTI)

The present invention relates to an empirical electrical method for remote sensing of steam quality utilizing flow-through grids which allow measurement of the electrical properties of a flowing two-phase mixture. The measurement of steam quality in the oil field is important to the efficient application of steam assisted recovery of oil. Because of the increased energy content in higher quality steam it is important to maintain the highest possible steam quality at the injection sandface. The effectiveness of a steaming operation without a measure of steam quality downhole close to the point of injection would be difficult to determine. Therefore, a need exists for the remote sensing of steam quality.

Lee, D.O.; Montoya, P.C.; Muir, J.F.; Wayland, J.R. Jr.

1985-06-19T23:59:59.000Z

82

Steam Champions in Manufacturing  

E-Print Network (OSTI)

Traditionally, industrial steam system management has focused on operations and maintenance. Competitive pressures, technology evolution, and increasingly complex regulations provide additional management challenges. The practice of operating a steam system demands the managerial expertise of a "Steam Champion," which will be described in this paper. Briefly, the steam champion is a facility professional who embodies the skills, leadership, and vision needed to maximize the effectiveness of a plant's steam system. Perhaps more importantly, the steam champion's definitive role is that of liaison between the manufacturer's boardroom and the plant floor. As such, the champion is able to translate the functional impacts of steam optimization into equivalent corporate rewards, such as increased profitability, reliability, workplace safety, and other benefits. The prerequisites for becoming a true steam champion will include engineering, business, and management skills.

Russell, C.

2001-05-01T23:59:59.000Z

83

Steam Digest 2001  

SciTech Connect

Steam Digest 2001 chronicles BestPractices Program's contributions to the industrial trade press for 2001, and presents articles that cover technical, financial and managerial aspects of steam optimization.

Not Available

2002-01-01T23:59:59.000Z

84

Steam Turbine Cogeneration  

E-Print Network (OSTI)

Steam turbines are widely used in most industrial facilities because steam is readily available and steam turbine is easy to operate and maintain. If designed properly, a steam turbine co-generation (producing heat and power simultaneously) system can increase energy efficiency, reduce air emissions and qualify the equipment for a Capital Cost tax Allowance. As a result, such a system benefits the stakeholders, the society and the environment. This paper describes briefly the types of steam turbine classified by their conditions of exhaust and review quickly the fundamentals related to steam and steam turbine. Then the authors will analyze a typical steam turbine co-generation system and give examples to illustrate the benefits of the System.

Quach, K.; Robb, A. G.

2008-01-01T23:59:59.000Z

85

Boiler and Heat Recovery Steam Generator Tube Failures: Theory and Practice  

Science Conference Proceedings (OSTI)

Boiler and heat recovery steam generator (HRSG) tube failures have been the primary availability problem for operators of conventional and combined cycle plants for as long as reliable statistics have been kept for each generating source. This book provides owners and operators with the technical basis to address tube failures and create permanent solutions.

2011-12-23T23:59:59.000Z

86

Generation Maintenance Application Center: Combustion Turbine Combined-Cycle Heat Recovery Steam Generator Maintenance Guide  

Science Conference Proceedings (OSTI)

This guide provides information to assist personnel involved with the maintenance of the heat recovery steam generator at a combustion gas turbine combined cycle facility, including good maintenance practices, preventive maintenance techniques and troubleshooting guidance. BackgroundCombustion turbine combined cycle (CTCC) facilities utilize various components that can be unique to this particular type of power plant. As such, owners and ...

2013-05-15T23:59:59.000Z

87

Steam Trap Application  

E-Print Network (OSTI)

The effective application of steam traps encompasses three primary areas which are the selection and sizing, the installation, and the monitoring of the steam trapping system. Proper application of steam traps will improve production rates, product quality, and reduce energy and maintenance costs.

Murphy, J. J.

1982-01-01T23:59:59.000Z

88

Steam System Optimization  

E-Print Network (OSTI)

Refinery and chemical plant steam systems are complex and the fuel required to produce the steam represents a major expense. The incremental cost for generating a 1,000 lb./hr. of steam is typically $45,000 - $60,000/year. Most plants have numerous low/

Aegerter, R.

2004-01-01T23:59:59.000Z

89

DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference...

90

Steam trap monitor  

DOE Patents (OSTI)

A steam trap monitor positioned downstream of a steam trap in a closed steam system includes a first sensor (a hot finger) for measuring the energy of condensate and a second sensor (a cold finger) for measuring the total energy of condensate and steam in the line. The hot finger includes one or more thermocouples for detecting condensate level and energy, while the cold finger contains a liquid with a lower boiling temperature than that of water. Vapor pressure from the liquid is used to do work such as displacing a piston or bellow in providing an indication of total energy (steam + condensate) of the system. Processing means coupled to and responsive to outputs from the hot and cold fingers subtracts the former from the latter to provide an indication of the presence of steam downstream from the trap indicating that the steam trap is malfunctioning. 2 figs.

Ryan, M.J.

1987-05-04T23:59:59.000Z

91

Steam turbine control  

SciTech Connect

In a power plant which includes a steam turbine with main control valves for admitting steam into the steam turbine and a steam bypass with bypass control valves for diverting steam around the steam turbine directly into a condenser, it is necessary to coordinate the operation of the respective valves so that the steam turbine can be started, brought up to speed, synchronized with a generator and then loaded as smoothly and efficiently as possible. The present invention provides for such operation and, in addition, allows for the transfer of power plant operation from the so-called turbine following mode to the boiler following mode through the use of the sliding pressure concept. The invention described is particularly applicable to combined cycle power plants.

Priluck, D.M.; Wagner, J.B.

1982-05-11T23:59:59.000Z

92

Steam And Condensate Diagnostic Expert System  

E-Print Network (OSTI)

This paper describes the outcome of a collaborative project to develop an operational expert system prototype that will help mill operators and engineers to troubleshoot and optimize the steam and condensate portion of paper machine dryer sections. The functionality of the prototype and results of mill validation tests are described. INTRODUCTION The purpose of this paper is to follow up on the status of a collaborative expert system (ES) development project presented at the 80th (1994) CPPA Technical Section Meeting. [1] The global objective of this one-year project was to apply the capabilities of expert systems to a paper machine, through the development of a practical operational prototype that assists operators to increase productivity and efficiency. Specifically, this Paper Drying Expert System (PDES) helps them to troubleshoot and optimize the steam and condensate (S&C) portion of the drying section of a paper machine. The project began in September 1993 and was completed in ...

Amyot Gowing Wylie; R. Amyot; J. Gowing; R. Wylie; R. Henzell; J. Futcher; J. Reinsborough; A. Coderre; P. Henzell; O. Vadas; Coulter Place

1995-01-01T23:59:59.000Z

93

Steam generator support system  

SciTech Connect

A support system for connection to an outer surface of a J-shaped steam generator for use with a nuclear reactor or other liquid metal cooled power source. The J-shaped steam generator is mounted with the bent portion at the bottom. An arrangement of elongated rod members provides both horizontal and vertical support for the steam generator. The rod members are interconnected to the steam generator assembly and a support structure in a manner which provides for thermal distortion of the steam generator without the transfer of bending moments to the support structure and in a like manner substantially minimizes forces being transferred between the support structure and the steam generator as a result of seismic disturbances.

Moldenhauer, James E. (Simi Valley, CA)

1987-01-01T23:59:59.000Z

94

Steam turbine plant  

SciTech Connect

A system for regulating the rate of closing of the turbine intake valve of a steam turbine plant is disclosed. A steam turbine is supplied from a steam generator through a turbine intake valve. A branch line conducts the steam to a bypass valve which is normally closed. In the event of conditions making it necessary to close the turbine intake valve rapidly, a regulator is provided to control the rate of closing of the turbine intake valve and the opening of the bypass valve so that the pressure conditions in the steam generator do not exceed the limits established by the manufacturer. Pressure measuring instruments are placed in the system to sense the pressure immediately upstream from the turbine intake valve and the bypass valve as well as the initial steam supply pressure. These pressure signals are transmitted to a computer which produces a control signal in accordance with predetermined conditions.

Skala, K.

1981-06-09T23:59:59.000Z

95

Steam generator support system  

DOE Patents (OSTI)

A support system for connection to an outer surface of a J-shaped steam generator for use with a nuclear reactor or other liquid metal cooled power source is disclosed. The J-shaped steam generator is mounted with the bent portion at the bottom. An arrangement of elongated rod members provides both horizontal and vertical support for the steam generator. The rod members are interconnected to the steam generator assembly and a support structure in a manner which provides for thermal distortion of the steam generator without the transfer of bending moments to the support structure and in a like manner substantially minimizes forces being transferred between the support structure and the steam generator as a result of seismic disturbances. 4 figs.

Moldenhauer, J.E.

1987-08-25T23:59:59.000Z

96

Flash Steam Recovery Project  

E-Print Network (OSTI)

One of the goals of Vulcan's cost reduction effort is to reduce energy consumption in production facilities through energy optimization. As part of this program, the chloromethanes production unit, which produces a wide variety of chlorinated organic compounds, was targeted for improvement. This unit uses a portion of the high-pressure steam available from the plant's cogeneration facility. Continuous expansions within the unit had exceeded the optimum design capacity of the unit's steam/condensate recovery system, resulting in condensate flash steam losses to the atmosphere. Using computer simulation models and pinch analysis techniques, the Operational Excellence Group (Six Sigma) was able to identify a project to recover the flash steam losses as a supplemental low-pressure steam supply. The project was designed and implemented at no capital cost using existing instrumentation and controls. On an annualized basis steam usage per ton of product fell by about three percent. Absolute savings were about 15,800 million Btu.

Bronhold, C. J.

2000-04-01T23:59:59.000Z

97

Steam Generator Management Program  

Science Conference Proceedings (OSTI)

The 24th EPRI Steam Generator NDE Workshop took place in San Diego, California, July 1113, 2005. It covered one full day and two half days of presentations. Attendees included representatives from domestic and overseas nuclear utilities, nuclear steam supply system (NSSS) vendors, nondestructive evaluation (NDE) service and equipment organizations, research laboratories, and regulatory bodies. This annual workshop serves as a forum for NDE specialists to gather and discuss current steam generator NDE iss...

2005-12-08T23:59:59.000Z

98

Downhole steam injector  

SciTech Connect

An improved downhole steam injector has an angled water orifice to swirl the water through the device for improved heat transfer before it is converted to steam. The injector also has a sloped diameter reduction in the steam chamber to throw water that collects along the side of the chamber during slant drilling into the flame for conversion to steam. In addition, the output of the flame chamber is beveled to reduce hot spots and increase efficiency, and the fuel-oxidant inputs are arranged to minimize coking.

Donaldson, A. Burl (Albuquerque, NM); Hoke, Donald E. (Albuquerque, NM)

1983-01-01T23:59:59.000Z

99

Steam Turbine Developments  

Science Conference Proceedings (OSTI)

...O. Jonas, Corrosion of Steam Turbines, Corrosion: Environments and Industries, Vol 13C, ASM Handbook, ASM International, 2006, p 469â??476...

100

Steam and Condensate Systems  

E-Print Network (OSTI)

In the late 60's and early 70's oil was plentiful and steam was relatively inexpensive. The switch to low sulphur fuel oil and the oil embargo suddenly changed the picture. The cost of steam rose from about $0.50 per 1,000# to $3.00 or more. Many see costs of $5.00 per 1,000# by 1980. These tremendous increases have caused steam systems, steam traps and condensate systems to become a major factor in overall plant efficiency and profit.

Yates, W.

1979-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Steam and Condensate Systems  

E-Print Network (OSTI)

In the late 60's and early 70's oil was plentiful and steam was relatively inexpensive. The switch to low sulphur fuel oil and the oil embargo suddenly changed the picture. The cost of steam rose from $0.50 per 1,000# to today's cost of $4.00 or more. Many see costs of $6.00/$7.00 in the near future. These tremendous increases have caused steam systems, steam traps and condensate systems to become a major factor in overall plant efficiency and profit.

Yates, W.

1980-01-01T23:59:59.000Z

102

Boiler steam engine with steam recovery and recompression  

SciTech Connect

A boiler type of steam engine is described which uses a conventional boiler with an external combustion chamber which heats water in a pressure chamber to produce steam. A mixing chamber is used to mix the steam from the boiler with recovered recompressed steam. Steam from the mixing chamber actuates a piston in a cylinder, thereafter the steam going to a reservoir in a heat exchanger where recovered steam is held and heated by exhaust gases from the combustion chamber. Recovered steam is then recompressed while being held saturated by a spray of water. Recovered steam from a steam accumulator is then used again in the mixing chamber. Thus, the steam is prevented from condensing and is recovered to be used again. The heat of the recovered steam is saved by this process.

Vincent, O.W.

1980-12-23T23:59:59.000Z

103

STEAM GENERATOR FOR NUCLEAR REACTOR  

DOE Patents (OSTI)

The steam generator described for use in reactor powergenerating systems employs a series of concentric tubes providing annular passage of steam and water and includes a unique arrangement for separating the steam from the water. (AEC)

Kinyon, B.W.; Whitman, G.D.

1963-07-16T23:59:59.000Z

104

Which idling reduction system is most economical for truck owners?  

NLE Websites -- All DOE Office Websites (Extended Search)

Which idling reduction system is Which idling reduction system is most economical for truck owners? Linda Gaines Center for Transportation Research Argonne National Laboratory Commercial Vehicle Engineering Congress and Exposition Rosemont, Il October 7-9, 2008 The price of diesel is high *Idling a Class 8 truck uses 0.6-1.2 gallons per hour *That can total over $50 a night! *So even without regulations, there's an incentive to reduce idling *Even if the price goes down more, idling reduction makes sense 2 Why do sleepers idle overnight? For services to resting driver and friend y Heating, ventilation, and air conditioning (HVAC) y Power for appliances 8TV, microwave, refrigerator, computer, hair drier To keep fuel and engine warm To mask out noises and smells Because other drivers do it

105

Steam generator designs  

SciTech Connect

A combined cycle is any one of combinations of gas turbines, steam generators or heat recovery equipment, and steam turbines assembled for the reduction in plant cost or improvement of cycle efficiency in the utility power generation process. The variety of combined cycles discussed for the possibilities for industrial applications include gas turbine plus unfired steam generator; gas turbine plus supplementary fired steam generator; gas turbine plus furnace-fired steam generator; and supercharged furnace-fired system generator plus gas turbine. These units are large enough to meet the demands for the utility applications and with the advent of economical coal gasification processes to provide clean fuel, the combined-cycle applications are solicited. (MCW)

Clayton, W.H.; Singer, J.G.

1973-07-01T23:59:59.000Z

106

Guide to Combined Heat and Power Systems for Boiler Owners and Operators  

Science Conference Proceedings (OSTI)

Combined heat and power (CHP) or cogeneration is the sequential production of two forms of useful energy from a single fuel source. In most CHP applications, chemical energy in fuel is converted to both mechanical and thermal energy. The mechanical energy is generally used to generate electricity, while the thermal energy or heat is used to produce steam, hot water, or hot air. Depending on the application, CHP is referred to by various names including Building Cooling, Heating, and Power (BCHP); Cooling, Heating, and Power for Buildings (CHPB); Combined Cooling, Heating, and Power (CCHP); Integrated Energy Systems (IES), or Distributed Energy Resources (DER). The principal technical advantage of a CHP system is its ability to extract more useful energy from fuel compared to traditional energy systems such as conventional power plants that only generate electricity and industrial boiler systems that only produce steam or hot water for process applications. By using fuel energy for both power and heat production, CHP systems can be very energy efficient and have the potential to produce electricity below the price charged by the local power provider. Another important incentive for applying cogeneration technology is to reduce or eliminate dependency on the electrical grid. For some industrial processes, the consequences of losing power for even a short period of time are unacceptable. The primary objective of the guide is to present information needed to evaluate the viability of cogeneration for new or existing industrial, commercial, and institutional (ICI) boiler installations and to make informed CHP equipment selection decisions. Information presented is meant to help boiler owners and operators understand the potential benefits derived from implementing a CHP project and recognize opportunities for successful application of cogeneration technology. Topics covered in the guide follow: (1) an overview of cogeneration technology with discussions about benefits of applying cogeneration technology and barriers to implementing cogeneration technology; (2) applicable federal regulations and permitting issues; (3) descriptions of prime movers commonly used in CHP applications, including discussions about design characteristics, heat-recovery options and equipment, fuels and emissions, efficiency, maintenance, availability, and capital cost; (4) electrical generators and electrical interconnection equipment; (5) cooling and dehumidification equipment; (6) thermodynamic cycle options and configurations; (7) steps for evaluating the technical and economic feasibility of applying cogeneration technology; and (8) information sources.

Oland, CB

2004-08-19T23:59:59.000Z

107

Streams of Steam The Steam Boiler Specification Case Study  

E-Print Network (OSTI)

Streams of Steam ­ The Steam Boiler Specification Case Study Manfred Broy, Franz Regensburger-tuned con- cepts of FOCUS by its application of the requirements specification of a steam boiler, see [Abr96-studies. In this context, applying FOCUS to the steam boiler case study ([Abr96]) led us to a couple of questions re- #12

Cengarle, María Victoria

108

Steam trap monitor  

DOE Patents (OSTI)

A steam trap monitor positioned downstream of a steam trap in a closed steam system includes a first sensor (the combination of a hot finger and thermocouple well) for measuring the energy of condensate and a second sensor (a cold finger) for measuring the total energy of condensate and steam in the line. The hot finger includes one or more thermocouples for detecting condensate level and energy, while the cold finger contains a liquid with a lower boiling temperature than that of water. Vapor pressure from the liquid is used to do work such as displacing a piston or bellows in providing an indication of total energy (steam+condensate) of the system. Processing means coupled to and responsive to outputs from the thermocouple well hot and cold fingers subtracts the condensate energy as measured by the hot finger and thermocouple well from the total energy as measured by the cold finger to provide an indication of the presence of steam downstream from the trap indicating that the steam trap is malfunctioning.

Ryan, Michael J. (Plainfield, IL)

1988-01-01T23:59:59.000Z

109

Steam generator replacement overview  

Science Conference Proceedings (OSTI)

Since nuclear power began to be widely used for commercial purposes in the 1960s, unit operators have experienced a variety of problems with major components. Although many of the problems have diminished considerably, those associated with pressurized water reactor (PWR) steam generators persist. Steam generator problems rank second, behind refueling outages, as the most significant contributor to lost electricity generation. As of December 31, 1995, 38 steam generators had been replaced in 13 of the 72 operating PWRs, and three units had been shut down prematurely, due primarily (or partially) to degradation of their steam generators: Portland General Electric`s Trojan unit, located in Prescott, OR, in 1992; Southern California Edison`s San Onofre 1, located in San Clemente, CA, in 1992; and Sacramento Municipal Utility District`s Rancho Seco unit in 1989. In the coming years, operators of PWRs in the US with degraded steam generators will have to decide whether to make annual repairs (with eventual derating likely), replace the generators or shut the plants down prematurely. To understand the issues and decisions utility managers face, this article examines problems encountered at steam generators over the past few decades and identifies some of the remedies that utility operators and the nuclear community have employed, including operational changes, maintenance, repairs and steam generator replacement.

Chernoff, H. [Science Applications International Corp., McLean, VA (United States); Wade, K.C. [USDOE Energy Information Administration, Washington, DC (United States)

1996-01-01T23:59:59.000Z

110

Waste Steam Recovery  

E-Print Network (OSTI)

An examination has been made of the recovery of waste steam by three techniques: direct heat exchange to process, mechanical compression, and thermocompression. Near atmospheric steam sources were considered, but the techniques developed are equally applicable to other sources of steam. The interaction of the recovery system with the plant's steam/power system has been included. Typical operating economics have been prepared. It was found that the profitability of most recovery schemes is generally dependent on the techniques used, the existing steam/power system, and the relative costs of steam and power. However, there will always be site-specific factors to consider. It is shown that direct heat exchange and thermocompression will always yield an energy profit when interacting with PRVs in the powerhouse. A set of typical comparisons between the three recovery techniques, interacting with various powerhouse and plant steam system configurations, is presented. A brief outline of the analysis techniques needed to prepare the comparison is also shown. Only operating costs are examined; capital costs are so size - and site-specific as to be impossible to generalize. The operating cost savings may be used to give an indication of investment potential.

Kleinfeld, J. M.

1979-01-01T23:59:59.000Z

111

Ukraine Steam Partnership  

SciTech Connect

The Ukraine Steam Partnership program is designed to implement energy efficiency improvements in industrial steam systems. These improvements are to be made by the private plants and local government departments responsible for generation and delivery of energy to end-users. One of the activities planned under this program was to provide a two-day training workshop on industrial steam systems focusing on energy efficiency issues related to the generation, distribution, and consumption of steam. The workshop was geared towards plant managers, who are not only technically oriented, but are also key decision makers in their respective companies. The Agency for Rational Energy Use and Ecology (ARENA-ECO), a non-governmental, not-for-profit organization founded to promote energy efficiency and environmental protection in Ukraine, in conjunction with the Alliance staff in Kiev sent out invitations to potential participants in all the regions of Ukraine. The purpose of this report is the describe the proceedings from the workshop and provide recommendations from the workshop's roundtable discussion. The workshop was broken down into two main areas: (1) Energy efficient boiler house steam generation; and Energy efficient steam distribution and consumption. The workshop also covered the following topics: (1) Ukrainian boilers; (2) Water treatment systems; (3) A profile of UKRESCO (Ukrainian Energy Services Company); (4) Turbine expanders and electricity generation; (5) Enterprise energy audit basics; and (6) Experience of steam use in Donetsk oblast.

Gurvinder Singh

2000-02-15T23:59:59.000Z

112

Steam deflector assembly for a steam injected gas turbine engine  

SciTech Connect

A steam injected gas turbine engine is described having a combustor, a casing for the combustor and an annular manifold comprising a part of the casing, the annular manifold having an exterior port formed therein and a plurality of holes formed in the manifold leading to the interior of the combustor, the improvement comprising a steam carrying line connected to the port and a steam deflector means for protecting the casing from direct impingement by the steam from the steam line and for distributing the steam about the annular manifold, the steam deflector means being mounted adjacent the port and within the manifold.

Holt, G.A. III.

1993-08-31T23:59:59.000Z

113

Steam generator tube failures  

SciTech Connect

A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

1996-04-01T23:59:59.000Z

114

Initial steam flow regulator for steam turbine start-up  

SciTech Connect

In a combined steam generator-turbine system, a drain type is provided in front of the stop valve to drain the first steam supply with the stop valve closed until the temperature of the valve and/or the temperature of the steam exceeds the temperature of saturation by a predetermined amount, and logic circuitry is provided to generate permissive signals which combine to allow successive admission of steam to the gland seal and to the steam turbine.

Martens, A.; Hobbs, M. M.

1985-12-31T23:59:59.000Z

115

Materials Performance in USC Steam  

DOE Green Energy (OSTI)

Materials Performance in USC Steam: (1) pressure effects on steam oxidation - unique capability coming on-line; (2) hydrogen evolution - hydrogen permeability apparatus to determine where hydrogen goes during steam oxidation; and (3) NETL materials development - steam oxidation resource for NETL developed materials.

G. R. Holcomb; J. Tylczak; G. H. Meier; N. M. Yanar

2011-09-07T23:59:59.000Z

116

DOE/NNSA Facility Management Contracts Facility Owner Contractor  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Facility Management Contracts Facility Management Contracts Facility Owner Contractor Award Date End Date Options/Award Term Ultimate Potential Expiration Date Contract FY Competed Parent Companies/ LLC Partners DOE Site Procurement Director DOE Contracting Officer SLAC National Accelerator Laboratory (SLAC) SC Stanford University DE-AC03-76SF00515 1/25/1981 9/30/2017 9/30/2017 M&O 1981 Stanford University Barbara Jackson 865-576-0976 Kyong H. Watson 650-926-5203 Pacific Northwest National Laboratory (PNNL) SC Battelle Memorial Institute DE-AC05-76RL01830 12/30/2002 9/30/2017 9/30/2017 M&O 1965 Battelle Memorial Institute Barbara Jackson 865-576-0976 Ryan Kilbury 509-372-4030 Brookhaven National Laboratory (BNL) SC Brookhaven Science Associates, LLC DE-AC02-98CH10886 1/5/1998 1/4/2015 1/4/2015 M&O 1998 Battelle Memorial Institute

117

DOE/NNSA Facility Management Contracts Facility Owner Contractor  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Facility Management Contracts Facility Management Contracts Facility Owner Contractor Award Date End Date Options/Award Term Ultimate Potential Expiration Date Contract FY Competed Parent Companies/ LLC Partners DOE Site Procurement Director DOE Contracting Officer SLAC National Accelerator Laboratory (SLAC) SC Stanford University DE-AC03-76SF00515 1/25/1981 9/30/2017 9/30/2017 M&O 1981 Stanford University Barbara Jackson 865-576-0976 Kyong H. Watson 650-926-5203 Pacific Northwest National Laboratory (PNNL) SC Battelle Memorial Institute DE-AC05-76RL01830 12/30/2002 9/30/2017 9/30/2017 M&O 1965 Battelle Memorial Institute Barbara Jackson 865-576-0976 Ryan Kilbury 509-372-4030 Brookhaven National Laboratory (BNL) SC Brookhaven Science Associates, LLC DE-AC02-98CH10886 1/5/1998 1/4/2015 1/4/2015 M&O 1998 Battelle Memorial Institute

118

Keywords Europe Home-owners Housing wealth Pensions Welfare  

E-Print Network (OSTI)

Abstract Notwithstanding current market volatility, there has been exceptional expansion in owner-occupied housing sectors and increases in house prices across European countries in recent decades. In the EU, individual wealth held in housing equity, especially among older people, has been considered a substantial reserve that could be tapped into to meet future pension needs as the ageing of the population becomes a greater stress on European welfare states. This paper seeks to take the notion of ‘property-based welfare’ further by examining, in principle at least, how home ownership may function as a pension across EU states. This firstly involves very approximate estimates of the types of, and rates of, income homeowners could hypothetically generate from their homes, including forms of income in kind. Secondly, criteria are identified to estimate how ‘adequate ’ such potential incomes are in relation to working incomes and in bringing retired households above poverty levels. Thirdly, different circumstances across EU member states with regard to existing housing and pension arrangements are examined. Broad national groupings appear evident, with housing income having least impact in older member states in central and northern Europe. The paper concludes that while the potential outcome of housing wealth is country specific, in many cases, greater dependency on home ownership in welfare provision, particularly if it is used as a substitute rather than a complement to existing arrangements, may have adverse consequences for many.

John Doling; Richard Ronald; J. Doling; R. Ronald; R. Ronald

2009-01-01T23:59:59.000Z

119

SUBJECT: Insights and Implications of Steam Generator Operating, Inspecting and Maintenance Experience  

E-Print Network (OSTI)

The steam generator tube failure event at Indian Point Unit 2 and the potential issues surrounding the in-situ pressure testing of selected tubes and test specimens at Arkansas Nuclear One Unit 2, prompted industry to evaluate its generic steam generator guidelines, plant experiences, and insights gained from the periodic steam generator program review visits conducted by the Institute of Nuclear Power Operations (INPO). The purpose of this letter is to share with the NRC staff the industry conclusions and actions taken. As the NRC staff is well aware, the operation, inspection, and maintenance of steam generators are a high industry priority. Given the critical role of the steam generator in providing safe, reliable, and economic power production, steam generator performance has received broad industry attention for years. Generic industry activities, managed by EPRI, have been underway continuously since 1978. NRC staff is familiar with those efforts based on past briefings on the activities of the EPRI Steam Generator Management Program (SGMP) and attendance at selected SGMP workshops. More recently, other industry support organizations, such as NEI, INPO, and NSSS Owners Groups, have played important roles as well. Industry data indicates continual improvement in steam generator performance since the initiation of these efforts.

David J. Modeen; Dr. Brian; W. Sheron

2000-01-01T23:59:59.000Z

120

Overheating in Hot Water- and Steam-Heated Multifamily Buildings  

Science Conference Proceedings (OSTI)

Apartment temperature data have been collected from the archives of companies that provide energy management systems (EMS) to multifamily buildings in the Northeast U.S. The data have been analyzed from more than 100 apartments in eighteen buildings where EMS systems were already installed to quantify the degree of overheating. This research attempts to answer the question, 'What is the magnitude of apartment overheating in multifamily buildings with central hot water or steam heat?' This report provides valuable information to researchers, utility program managers and building owners interested in controlling heating energy waste and improving resident comfort. Apartment temperature data were analyzed for deviation from a 70 degrees F desired setpoint and for variation by heating system type, apartment floor level and ambient conditions. The data shows that overheating is significant in these multifamily buildings with both hot water and steam heating systems.

Dentz, J.; Varshney, K.; Henderson, H.

2013-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

CYCLIC STEAM STIMULATION  

NLE Websites -- All DOE Office Websites (Extended Search)

CYCLIC STEAM STIMULATION ("Huff-and-Puff') (A well-stimulation method) This method is sometimes applied to heavy-oil reservoirs to boost recovery during the primary production...

122

Steam purity in PWRs  

Science Conference Proceedings (OSTI)

Impurities enter the secondary loop of the PWR through both makeup water from lake or well and cooling-water leaks in the condenser. These impurities can be carried to the steam generator, where they cause corrosion deposits to form. Corrosion products in steam are swept further through the system and become concentrated at the point in the low-pressure turbine where steam begins to condense. Several plants have effectively reduced impurities, and therefore corrosion, by installing a demineralizer for the makeup water, a resin-bed system to clean condensed steam from the condenser, and a deaerator to remove oxygen from the water and so lower the risk of system metal oxidation. 5 references, 1 figure.

Hopkinson, J.

1982-10-01T23:59:59.000Z

123

Economics of Steam Pressure Reduction  

E-Print Network (OSTI)

Economics of Steam Pressure Reduction is a technical paper that addresses the operating and economic advantages associated with the program to lower the steam operating pressure. Evaluation of a testing program will be discussed. The paper will address the following. 1. Factors that determine the feasibility of reducing the plant steam operating pressure. 2. The operating advantages and disadvantages associated with the decreased steam pressure. 3. The economics of steam pressure reduction. Appropriate visual aids will be utilized as part of the discussion.

Sylva, D. M.

1985-05-01T23:59:59.000Z

124

Evaluating Steam Trap Performance  

E-Print Network (OSTI)

Laboratory tests were conducted on several types of steam traps at Holston Defense Corporation in Kingsport, Tennessee. Data from these tests, which determined their relative efficiencies, were used in performing economic analyses to determine their equivalent uniform annual cost (EUAC). The comparison was made using a computer program written for the Apple II computer to evaluate overall steam trap economics. This program calculates the EUAC for any steam trap based on 12 input variables including capital, maintenance and steam costs, interest rate and trap life. After determinIng the EUAC, the program will perform sensitivity analyses on any of the twelve variables. (This computer program is available from the author.) This study shows that inverted bucket traps have lower EUAC's under more conditions than other types of traps. Also, this study shows that live steam loss is the heaviest contributor to the annual operating cost of any steam trap and that maintenance frequency and repair cost are also more important than a trap's first cost.

Fuller, N. Y.

1986-06-01T23:59:59.000Z

125

Measure Guideline: Steam System Balancing and Tuning for Multifamily Residential Buildings  

SciTech Connect

This report was written as a resource for professionals involved in multifamily audits, retrofit delivery, and program design, as well as for building owners and contractors. It is intended to serve as a guide for those looking to evaluate and improve the efficiency and operation of one-pipe steam heating systems. In centrally heated multifamily buildings with steam or hydronic systems, the cost of heat for tenants is typically absorbed into the owner's operating costs. Highly variable and rising energy costs have placed a heavy burden on landlords. In the absence of well-designed and relevant efficiency efforts, increased operating costs would be passed on to tenants who often cannot afford those increases. Misinvestment is a common problem with older heating systems -- multiple contractors may inadequately or inappropriately upgrade parts of systems and reduce system functionality and efficiency, or the system has not been properly maintained.

Choi, J.; Ludwig, P.; Brand, L.

2013-04-01T23:59:59.000Z

126

Personalized Face Verification System Using Owner-Specific Cluster-Dependent LDA-Subspace  

Science Conference Proceedings (OSTI)

In this paper, we propose an owner-specific cluster-dependent linear discriminant analysis (OSCD-LDA) method, and apply it to develop a personalized face verification system. Before the owner enrollment, our system first divides all the training face ...

Hsien-Chang Liu; Chan-Hung Su; Yueh-Hsuan Chiang; Yi-Ping Hung

2004-08-01T23:59:59.000Z

127

Flash drying protects standby plants  

Science Conference Proceedings (OSTI)

This article describes how special fast-drying technique provides effective corrosion protection for units that will be in standby for a short time. The Jacksonville Electric Authority (JEA) has developed a technique for rapidly drying out its boilers as an effective corrosion prevention measure, even for units which will be out of service for a short time. The JEA has several steam generating units that are not in continual service. These units, whether on standby or in extended cold storage, must be maintained if they are to operate reliably when they are needed. JEA uses dehumidification as the primary method to reduce corrosion in these standby units. Engineers at JEA believe it is better to reduce the amount of water retained in standby boilers than to add inhibiting chemicals to retained water for corrosion protection.

Mallard, R.E.

1996-08-01T23:59:59.000Z

128

DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NSTB Researchers Demonstrate R&D Successes to Asset Owners at NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference More than 150 energy sector leaders-including nearly 100 asset owners and operators-gathered at the 2009 EnergySec Annual Summit in Seattle, WA, on Sept. 23-24, where researchers from the Department of Energy's National SCADA Test Bed (NSTB) Program gave a four-hour demonstration and presentation of their Roadmap-related control systems security work. DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference More Documents & Publications DOE/OE National SCADA Test Bed Fiscal Year 2009 Work Plan Security is Not an Option DOE National SCADA Test Bed Program Multi-Year Plan

129

DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference October 1, 2009 - 1:26pm Addthis More than 150 energy sector leaders-including nearly 100 asset owners and operators-gathered at the 2009 EnergySec Annual Summit in Seattle, WA, on Sept. 23-24, where researchers from the Department of Energy's National SCADA Test Bed (NSTB) Program gave a four-hour demonstration and presentation of their Roadmap-related control systems security work. EnergySec is an information sharing forum with more than 230 utility members representing 75 energy companies across the nation. Its fifth annual conference drew asset owners, vendors, and government

130

Evaluation of Thermal-, Creep-, and Corrosion-Fatigue of Heat Recovery Steam Generator Pressure Parts  

Science Conference Proceedings (OSTI)

The worldwide fleet of combined cycle units with heat recovery steam generators (HRSG) has exhibited a disappointing track record with respect to reliability and availability in terms of fatigue HRSG tube failures (HTF) which are thermal transient driven. This report, which forms part of a series, will assist designer, owners, and operators with the technical basis to facilitate specifying, designing, and operating HRSG in a manner to minimize fatigue damage.

2006-03-31T23:59:59.000Z

131

Steam Heat: Winter Fountains in the City  

E-Print Network (OSTI)

Joan Brigham Steam Heat: Winter Fountains int h e City Steam is a phenomenon of the winter city. Iteven when the surging steam temporarily blinds them. When I

Brigham, Joan

1990-01-01T23:59:59.000Z

132

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network (OSTI)

DOE's BestPractices Steam End User Training Steam End User Training Steam Distribution Losses Module 1 June 29, 2010 Steam EndUser Training Steam Distribution System Losses Module Slide 1 Steam Distribution System Losses Module The steam distribution system typically consists of main steam

Oak Ridge National Laboratory

133

Method for improving the steam splits in a multiple steam injection process  

SciTech Connect

This patent describes a method for enhancing the uniformity of steam distribution in a multiple steam injection system comprising a steam generator, a steam header, a primary steam line connecting the generator to the header, and secondary steam lines connecting the header to steam injection wells. It comprises: injecting a surfactant into the primary steam line, and mixing the surfactant and steam sufficiently so that the surfactant and the steam enter the header as a foam.

Stowe, G.R. III.

1990-09-04T23:59:59.000Z

134

Steam Generator Management Program: Steam Generator Engineering Training Course 1  

Science Conference Proceedings (OSTI)

This technical update provides training material that was prepared for the first of three Steam Generator Engineer Training Program courses. The Steam Generator Engineer Training Program is a comprehensive training program of the Steam Generator Management Program. The content of this course is based on an industry-developed job analysis for a steam generator engineer. The job analysis resulted in eight high-level tasks; therefore, eight training modules will be developed over a three-year period beginni...

2009-03-25T23:59:59.000Z

135

Optical wet steam monitor  

DOE Patents (OSTI)

A wet steam monitor determines steam particle size by using laser doppler velocimeter (LDV) device to produce backscatter light. The backscatter light signal is processed with a spectrum analyzer to produce a visibility waveform in the frequency domain. The visibility waveform includes a primary peak and a plurality of sidebands. The bandwidth of at least the primary frequency peak is correlated to particle size by either visually comparing the bandwidth to those of known particle sizes, or by digitizing the waveform and comparing the waveforms electronically.

Maxey, Lonnie C. (Powell, TN); Simpson, Marc L. (Knoxville, TN)

1995-01-01T23:59:59.000Z

136

Optical wet steam monitor  

DOE Patents (OSTI)

A wet steam monitor determines steam particle size by using laser doppler velocimeter (LDV) device to produce backscatter light. The backscatter light signal is processed with a spectrum analyzer to produce a visibility waveform in the frequency domain. The visibility waveform includes a primary peak and a plurality of sidebands. The bandwidth of at least the primary frequency peak is correlated to particle size by either visually comparing the bandwidth to those of known particle sizes, or by digitizing the waveform and comparing the waveforms electronically. 4 figures.

Maxey, L.C.; Simpson, M.L.

1995-01-17T23:59:59.000Z

137

Letter of Intent: Commercial Real Estate Developer/Owner | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

Letter of Intent: Commercial Real Estate Developer/Owner Letter of Intent: Commercial Real Estate Developer/Owner Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources

138

Deaerators in Industrial Steam Systems  

SciTech Connect

This revised ITP tip sheet on deaerators in industrial steam systems provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

139

Inspect and Repair Steam Traps  

SciTech Connect

This revised ITP tip sheet on inspecting and repairing steam traps provide how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

140

Steam generator tube rupture study  

E-Print Network (OSTI)

This report describes our investigation of steam generator behavior during a postulated tube rupture accident. Our study was performed using the steam generator, thermal-hydraulic analysis code THERMIT-UTSG. The purpose ...

Free, Scott Thomas

1986-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Belgrade Lot Steam Plant Lot  

E-Print Network (OSTI)

2 2A 2A Belgrade Lot Steam Plant Lot Alfond Lot Satellite Lot North Gym Lot Corbett Lot Dunn Lot Oceanographic Operations 1 2 8 5 3 4 7 6 AMC Chadbourne Merrill Aubert Hannibal Hamlin Steam Plant Crosby

Thomas, Andrew

142

Belgrade Lot Steam Plant Lot  

E-Print Network (OSTI)

2 2A 2A Belgrade Lot Steam Plant Lot Alfond Lot Satellite Lot North Gym Lot Corbett Lot Dunn Lot Chadbourne Merrill Aubert Hannibal Hamlin Steam Plant Crosby Machine Tool Lab Children's Center Rogers N

Thomas, Andrew

143

Belgrade Lot Steam Plant Lot  

E-Print Network (OSTI)

2 2A 2A Belgrade Lot Steam Plant Lot Alfond Lot Satellite Lot North Gym Lot Gym Lot Corbett Lot Greenhouse Patch Oceanographic Operations 1 2 8 5 3 4 7 6 AMC Chadbourne Merrill Aubert Hannibal Hamlin Steam

Thomas, Andrew

144

Fuzzy control of steam turbines  

Science Conference Proceedings (OSTI)

Keywords: PID control, comparison of PID and fuzzy control, fuzzy logic control, robustness, speed control, steam turbine control

N. Kiupel; P. M. Frank; O. Bux

1994-05-01T23:59:59.000Z

145

Steam Turbine Performance Engineer's Guide  

Science Conference Proceedings (OSTI)

The Steam Turbine Performance Engineer's Guide is meant to present the steam turbine performance engineer with the expected and important functions and responsibilities necessary to succeed in this position that are not necessarily taught in college. The instructions and recommendations in this guide, when properly executed, will improve the effectiveness of steam turbine performance engineers, positively affecting both the performance and reliability of the steam turbines under their care.

2010-12-23T23:59:59.000Z

146

Options for Generating Steam Efficiently  

E-Print Network (OSTI)

This paper describes how plant engineers can efficiently generate steam when there are steam generators and Heat Recovery Steam Generators in their plant. The process consists of understanding the performance characteristics of the various equipment as a function of load and operating them close to the maximum efficiency point.

Ganapathy, V.

1996-04-01T23:59:59.000Z

147

Group Member Names: ________________________________________________ Scenario: You are the owner of a potato plant in Idaho. You have recently won a contract  

E-Print Network (OSTI)

: ________________________________________________ ________________________________________________ ________________________________________________ Scenario: You are the owner of a potato plant in Idaho. You have recently won a contract to supply Mc

Provancher, William

148

STEAM GENERATOR PRELIMINARY DESIGN  

SciTech Connect

A conceptual study on design of sodium-cooled reactor steam generators was conducted. Included is a detailed description of the preliminary design and analysis, based on the use of known materials and existing methods of fabrication. (See also APAE-41 Vols. I and III.) (J.R.D.)

1959-02-28T23:59:59.000Z

149

MOTION TO INTERVENE OF THE NEW YORK TRANSMISSION OWNERS PP-230-4 |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

MOTION TO INTERVENE OF THE NEW YORK TRANSMISSION OWNERS PP-230-4 MOTION TO INTERVENE OF THE NEW YORK TRANSMISSION OWNERS PP-230-4 MOTION TO INTERVENE OF THE NEW YORK TRANSMISSION OWNERS PP-230-4 Pursuant to Rules 212 and 214 of the Rules of Practice and Procedure, 18 C.F.R. §§ 385.212 and 385.214 (2010), Central Hudson Gas & Electric Corporation, Consolidated Edison Company of New York, Inc., Long Island Power Authority, New York Power Authority, New York State Electric & Gas Corporation, Niagara Mohawk Power Corporation d/b/a National Grid, Orange and Rockland Utilities, Inc., and Rochester Gas and Electric Corporation (referred to herein as the "New York Transmission Owners"), individually and collectively move to intervene in the above-captioned proceeding and request an opportunity to comment on International Transmission Company's d/b/a/ ITCTransmission

150

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network (OSTI)

demands, and cogeneration. The Steam Distribution System Losses module will cover steam leaks, steam traps Analysis ­ (SSAT) Fuel selection Steam demands Cogeneration Steam Distribution System Losses - (3EDOE's BestPractices Steam End User Training Steam End User Training Welcome Module - 1 8

Oak Ridge National Laboratory

151

Steam assisted gas turbine engine  

SciTech Connect

A gas turbine engine is disclosed which has an integral steam power system consisting of heat absorbing boilers which convert an unpressurized liquid into an expanded and heated steam by utilizing heat normally lost through component cooling systems and the exhaust system. Upon completion of the steam power cycle, the steam is condensed back to a liquid state through a condensing system located within the compressor and other functional components of the gas turbine engine. A system of high pressure air and friction seals restrict steam or liquid condensate within designed flow bounds. The gas turbine engine disclosed is designed to give improved fuel efficiency and economy for aircraft and land use applications.

Coronel, P.D.

1982-06-08T23:59:59.000Z

152

A comparison of noxious facilities` impacts for home owners versus renters  

Science Conference Proceedings (OSTI)

The siting of noxious facilities, such as hazardous waste facilities, is often vigorously opposed by local residents, and thus it is now common for local residents to be compensated for the presence of the facility. One technique that has been employed to implicitly value noxious facilities is the intercity hedonic approach, which examines the wage and land rent premia between cities that result from the presence of the facility. However, most of the focus has been on the behavior of home owners as opposed to renters. Since these two groups of residents vary on numerous dimensions such as marital status, age, sex, and personal mobility, it would not be surprising to find different marginal valuations of local site characteristics. The authors use 1980 Census data to derive separate estimates for owners and renters of the implicit value placed on eight different types of noxious facilities. They find that renters and owners differ in their response to noxious facilities, although the differences are not systematic. Furthermore, the differences between owners and renters are not primarily due to differential mobility or socio-demographic factors. Controlling those factors decreases the differences between renters` and owners` implicit valuations of noxious facilities by less than 10%. Unmeasured differences between the two groups, such as tastes, risk aversion, or commitment to the community, must account for the remaining difference in valuations. These findings suggest that policymakers should separately consider the responses of owners and renters when estimating noxious facility impacts.

Clark, D.E. [Marquette Univ., Milwaukee, WI (United States). Dept. of Economics]|[Argonne National Lab., IL (United States); Nieves, L.A. [Argonne National Lab., IL (United States)

1995-01-01T23:59:59.000Z

153

Dry Lake Wind Farm | Open Energy Information  

Open Energy Info (EERE)

Wind Farm Wind Farm Jump to: navigation, search Name Dry Lake Wind Farm Facility Dry Lake Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Owner Iberdrola Renewables Developer Iberdrola Renewables Energy Purchaser Iberdrola Renewables Location Navajo County AZ Coordinates 34.635651°, -110.357351° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":34.635651,"lon":-110.357351,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

154

Steam System Balancing and Tuning  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Steam System Balancing and Steam System Balancing and Tuning Building America Stakeholder Meeting Austin, TX Jayne Choi, Energy Analyst, CNT Energy March 2, 2012 PARR Current collaboration with GTI as a part of the PARR Building America team - Steam Systems Balancing and Tuning Study - Heating season 2011-2012 Background In Chicago, heating is the focus of residential energy use Of the 470,000 multifamily units in the Chicago region, at least 70,000 of those are steam heated Old steam systems invariably suffer from imbalance - Tenants must use supplemental heat or open their windows to cool their apartments during the heating season Buildings are often overheated Problem Statement (CNT Energy) Steam Heating Steam heat was the best option for buildings constructed between 1900 and 1930

155

ADVANCED STEAM GENERATORS  

SciTech Connect

Concerns about climate change have encouraged significant interest in concepts for ultra-low or ''zero''-emissions power generation systems. In some proposed concepts, nitrogen is removed from the combustion air and replaced with another diluent such as carbon dioxide or steam. In this way, formation of nitrogen oxides is prevented, and the exhaust stream can be separated into concentrated CO{sub 2} and steam or water streams. The concentrated CO{sub 2} stream could then serve as input to a CO{sub 2} sequestration process or utilized in some other way. Some of these concepts are illustrated in Figure 1. This project is an investigation of one approach to ''zero'' emission power generation. Oxy-fuel combustion is used with steam as diluent in a power cycle proposed by Clean Energy Systems, Inc. (CES) [1,2]. In oxy-fuel combustion, air separation is used to produce nearly pure oxygen for combustion. In this particular concept, the combustion temperatures are moderated by steam as a diluent. An advantage of this technique is that water in the product stream can be condensed with relative ease, leaving a pure CO{sub 2} stream suitable for sequestration. Because most of the atmospheric nitrogen has been separated from the oxidant, the potential to form any NOx pollutant is very small. Trace quantities of any minor pollutants species that do form are captured with the CO{sub 2} or can be readily removed from the condensate. The result is a nearly zero-emission power plant. A sketch of the turbine system proposed by CES is shown in Figure 2. NETL is working with CES to develop a reheat combustor for this application. The reheat combustion application is unusual even among oxy-fuel combustion applications. Most often, oxy-fuel combustion is carried out with the intent of producing very high temperatures for heat transfer to a product. In the reheat case, incoming steam is mixed with the oxygen and natural gas fuel to control the temperature of the output stream to about 1480 K. A potential concern is the possibility of quenching non-equilibrium levels of CO or unburned fuel in the mixing process. Inadequate residence times in the combustor and/or slow kinetics could possibly result in unacceptably high emissions. Thus, the reheat combustor design must balance the need for minimal excess oxygen with the need to oxidize the CO. This paper will describe the progress made to date in the design, fabrication, and simulation of a reheat combustor for an advanced steam generator system, and discuss planned experimental testing to be conducted in conjunction with NASA Glenn Research Center-Plumb Brook Station.

Richards, Geo. A.; Casleton, Kent H.; Lewis, Robie E.; Rogers, William A. (U.S. DOE National Energy Technology Laboratory); Woike, Mark R.; Willis; Brian P. (NASA Glenn Research Center)

2001-11-06T23:59:59.000Z

156

Crude oil steam distillation in steam flooding. Final report  

SciTech Connect

Steam distillation yields of sixteen crude oils from various parts of the United States have been determined at a saturated steam pressure of 200 psig. Study made to investigate the effect of steam pressure (200 to 500 psig) on steam distillation yields indicates that the maximum yields of a crude oil may be obtained at 200 psig. At a steam distillation correlation factor (V/sub w//V/sub oi/) of 15, the determined steam distillation yields range from 12 to 56% of initial oil volume for the sixteen crude oils with gravity ranging from 12 to 40/sup 0/API. Regression analysis of experimental steam distillation yields shows that the boiling temperature (simulated distillation temperature) at 20% simulated distillation yield can predict the steam distillation yields reasonably well: the standard error ranges from 2.8 to 3.5% (in yield) for V/sub w//V/sub oi/ < 5 and from 3.5 to 4.5% for V/sub w//V/sub oi/ > 5. The oil viscosity (cs) at 100/sup 0/F can predict the steam distillation yields with standard error from 3.1 to 4.3%. The API gravity can predict the steam distillation yields with standard error from 4.4 to 5.7%. Characterization factor is an unsatisfactory correlation independent variable for correlation purpose.

Wu, C.H.; Elder, R.B.

1980-08-01T23:59:59.000Z

157

dist_steam.pdf  

U.S. Energy Information Administration (EIA) Indexed Site

District Steam Usage Form District Steam Usage Form 1999 Commercial Buildings Energy Consumption Survey (CBECS) 1. Timely submission of this report is mandatory under Public Law 93-275, as amended. 2. This completed questionnaire is due by 3. Data reported on this questionnaire are for the entire building identified in the label to the right. 4. Data may be submitted directly on this questionnaire or in any other format, such as a computer-generated listing, which provides the same i nformation and is conve nient for y our company. a. You may submit a single report for the entire building, or if it i s easier, a separate report for each of several accounts in the building. These will then be aggregated by the survey contractor. b. If you are concerned about your individual account information, you may c

158

Water cooled steam jet  

DOE Patents (OSTI)

A water cooled steam jet for transferring fluid and preventing vapor lock, or vaporization of the fluid being transferred, has a venturi nozzle and a cooling jacket. The venturi nozzle produces a high velocity flow which creates a vacuum to draw fluid from a source of fluid. The venturi nozzle has a converging section connected to a source of steam, a diffuser section attached to an outlet and a throat portion disposed therebetween. The cooling jacket surrounds the venturi nozzle and a suction tube through which the fluid is being drawn into the venturi nozzle. Coolant flows through the cooling jacket. The cooling jacket dissipates heat generated by the venturi nozzle to prevent vapor lock.

Wagner, Jr., Edward P. (Idaho Falls, ID)

1999-01-01T23:59:59.000Z

159

Steam separator latch assembly  

SciTech Connect

A latch assembly removably joins a steam separator assembly to a support flange disposed at a top end of a tubular shroud in a nuclear reactor pressure vessel. The assembly includes an annular head having a central portion for supporting the steam separator assembly thereon, and an annular head flange extending around a perimeter thereof for supporting the head to the support flange. A plurality of latches are circumferentially spaced apart around the head flange with each latch having a top end, a latch hook at a bottom end thereof, and a pivot support disposed at an intermediate portion therebetween and pivotally joined to the head flange. The latches are pivoted about the pivot supports for selectively engaging and disengaging the latch hooks with the support flange for fixedly joining the head to the shroud or for allowing removal thereof.

Challberg, Roy C. (Livermore, CA); Kobsa, Irvin R. (San Jose, CA)

1994-01-01T23:59:59.000Z

160

Steam separator latch assembly  

DOE Patents (OSTI)

A latch assembly removably joins a steam separator assembly to a support flange disposed at a top end of a tubular shroud in a nuclear reactor pressure vessel. The assembly includes an annular head having a central portion for supporting the steam separator assembly thereon, and an annular head flange extending around a perimeter thereof for supporting the head to the support flange. A plurality of latches are circumferentially spaced apart around the head flange with each latch having a top end, a latch hook at a bottom end thereof, and a pivot support disposed at an intermediate portion therebetween and pivotally joined to the head flange. The latches are pivoted about the pivot supports for selectively engaging and disengaging the latch hooks with the support flange for fixedly joining the head to the shroud or for allowing removal thereof. 12 figures.

Challberg, R.C.; Kobsa, I.R.

1994-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Steam Condensation Induced Waterhammer  

E-Print Network (OSTI)

This is the type of waterhammer that kills people. It's initiating mechanism is much different than the image most engineers have of what causes waterhammer-- i.e. fast moving steam picking up a slug of condensate and hurling it downstream against an elbow or a valve. Condensation Induced Waterhammer can be 100 times more powerful than this type of waterhammer. Because it does not require flowing steam, it often occurs during relatively quiescent periods when operators least expect it. It's most often initiated by opening a valve, even a drain valve to remove condensate. The overpressure from an event can easily exceed 1000 psi. This is enough pressure to fracture a cast iron valve, blow out a steam gasket, or burst an accordion type expansion joint. And, in fact, failure of each of these components in separate condensation induced waterhammer accidents has resulted in operator fatalities. Operators and engineers need to understand this type of waterhammer so they can avoid procedures which can initiate it and designs which are susceptible to it.

Kirsner, W.

2000-04-01T23:59:59.000Z

162

Glossary Term - Dry Ice  

NLE Websites -- All DOE Office Websites (Extended Search)

Deuteron Previous Term (Deuteron) Glossary Main Index Next Term (Electron) Electron Dry Ice A block of dry ice sublimating on a table. Dry ice is the solid form of carbon dioxide...

163

Steam Generator Management Program: Alloy 800 Steam Generator Tubing Experience  

Science Conference Proceedings (OSTI)

Nuclear grade (NG) Alloy 800 has been used for steam generator tubing since 1972 in over 50 nuclear power plants worldwide. The operational performance of this alloy has been very good, although some degradation modes have recently been observed. This report describes worldwide operating experience for Alloy 800 steam generator tubing along with differences in tubing material, plant design, and operating conditions that can affect tube degradation. The various types of plants with Alloy 800 steam generat...

2012-06-26T23:59:59.000Z

164

Steam condensate leakage  

SciTech Connect

Argonne National Laboratory (ANL) is a multi-program research and development center owned by the United States Department of Energy and operated by the University of Chicago. The majority of the buildings on site use steam for heating and other purposes. Steam is generated from liquid water at the site`s central boiler house and distributed around the site by means of large pipes both above and below the ground. Steam comes into each building where it is converted to liquid condensate, giving off heat which can be used by the building. The condensate is then pumped back to the boiler house where it will be reheated to steam again. The process is continual but is not perfectly efficient. A substantial amount of condensate is being lost somewhere on site. The lost condensate has both economic and environmental significance. To compensate for lost condensate, makeup water must be added to the returned condensate at the boiler house. The water cost itself will become significant in the future when ANL begins purchasing Lake Michigan water. In addition to the water cost, there is also the cost of chemically treating the water to remove impurities, and there is the cost of energy required to heat the water, as it enters the boiler house 1000 F colder than the condensate return. It has been estimated that only approximately 60% of ANL`s steam is being returned as condensate, thus 40% is being wasted. This is quite costly to ANL and will become significantly more costly in the future when ANL begins purchasing water from Lake Michigan. This study locates where condensate loss is occurring and shows how much money would be saved by repairing the areas of loss. Shortly after completion of the study, one of the major areas of loss was repaired. This paper discusses the basis for the study, the areas where losses are occurring, the potential savings of repairing the losses, and a hypothesis as to where the unaccounted for loss is occurring.

Midlock, E.B.; Thuot, J.R.

1996-07-01T23:59:59.000Z

165

Steam Power Partnership: Improving Steam System Efficiency Through Marketplace Partnerships  

E-Print Network (OSTI)

The Alliance to Save Energy, a national nonprofit organization based in Washington DC, and the U.S. Department of Energy are working with energy efficiency suppliers to promote the comprehensive upgrade of industrial steam systems. Like EPA's Green Lights and DOE's Motor Challenge, the Steam Power Partnership program will encourage industrial energy consumers to retrofit their steam plants wherever profitable. The Alliance has organized a "Steam Team" of trade associations, consulting engineering firms, and energy efficiency companies to help develop this public- private initiative.

Jones, T.

1997-04-01T23:59:59.000Z

166

Steam generators, turbines, and condensers. Volume six  

SciTech Connect

Volume six covers steam generators (How steam is generated, steam generation in a PWR, vertical U-tube steam generators, once-through steam generators, how much steam do steam generators make.), turbines (basic turbine principles, impulse turbines, reaction turbines, turbine stages, turbine arrangements, turbine steam flow, steam admission to turbines, turbine seals and supports, turbine oil system, generators), and condensers (need for condensers, basic condenser principles, condenser arrangements, heat transfer in condensers, air removal from condensers, circulating water system, heat loss to the circulating water system, factors affecting condenser performance, condenser auxiliaries).

1986-01-01T23:59:59.000Z

167

Dry Lake II Wind Farm | Open Energy Information  

Open Energy Info (EERE)

Dry Lake II Wind Farm Dry Lake II Wind Farm Jump to: navigation, search Name Dry Lake II Wind Farm Facility Dry Lake II Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Owner Iberdrola Renewables Developer Iberdrola Renewables Energy Purchaser Salt River Project Location Northwest of Snowflake AZ Coordinates 34.635651°, -110.357351° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":34.635651,"lon":-110.357351,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

168

Air-cooled vacuum steam condenser  

SciTech Connect

This patent describes a steam powered system. It comprises: a turbine for converting steam energy into mechanical energy upon expansion of steam therein, a boiler for generating steam to be fed to the turbine, and a conduit arrangement coupling the boiler to the turbine and then recoupling the turbine exhaust to the boiler through steam condensing mechanisms.

Larinoff, M.W.

1990-02-27T23:59:59.000Z

169

Constant-Pressure Measurement of Steam-  

E-Print Network (OSTI)

SGP-TR-169 Constant-Pressure Measurement of Steam- Water Relative Permeability Peter A. O by measuring in-situ steam saturation more directly. Mobile steam mass fraction was established by separate steam and water inlets or by correlating with previous results. The measured steam-water relative

Stanford University

170

Steam pretreatment for coal liquefaction  

SciTech Connect

Steam pretreatment is the reaction of coal with steam at temperatures well below those usually used for solubilization. The objective of the proposed work is to test the application of steam pretreatment to coal liquefaction. This quarter, a 300 ml stirred autoclave for liquefaction tests were specified and ordered, procedures for extraction tests were reestablished, and the synthesis of four model compounds was completed. Two of these compounds remain to be purified.

Graff, R.A.; Balogh-Nair, V.

1990-01-01T23:59:59.000Z

171

Process for purifying geothermal steam  

DOE Patents (OSTI)

Steam containing hydrogen sulfide is purified and sulfur recovered by passing the steam through a reactor packed with activated carbon in the presence of a stoichiometric amount of oxygen which oxidizes the hydrogen sulfide to elemental sulfur which is adsorbed on the bed. The carbon can be recycled after the sulfur has been recovered by vacuum distillation, inert gas entrainment or solvent extraction. The process is suitable for the purification of steam from geothermal sources which may also contain other noncondensable gases.

Li, Charles T. (Richland, WA)

1980-01-01T23:59:59.000Z

172

Steam Pressure Reduction: Opportunities and Issues; A BestPractices Steam Technical Brief  

SciTech Connect

A BestPractices Technical Brief describing industrial steam generation systems and opportunities for reducing steam system operating pressure.

Not Available

2005-11-01T23:59:59.000Z

173

Degradation of Steam Generator Internals  

Science Conference Proceedings (OSTI)

Aug 1, 1999 ... Regulatory Perspective on Industry's Response to Generic Letter 97-06, " Degradation of Steam Generator Internals" by S. Coffin, M. Subudhi, ...

174

Downhole steam injector. [Patent application  

DOE Patents (OSTI)

An improved downhole steam injector has an angled water orifice to swirl the water through the device for improved heat transfer before it is converted to steam. The injector also has a sloped diameter reduction in the steam chamber to throw water that collects along the side of the chamber during slant drilling into the flame for conversion to steam. In addition, the output of the flame chamber is beveled to reduce hot spots and increase efficiency, and the fuel-oxidant inputs are arranged to minimize coking.

Donaldson, A.B.; Hoke, E.

1981-06-03T23:59:59.000Z

175

Step 8: Work with the building owner to complete the ENERGY STAR lifecycle  

NLE Websites -- All DOE Office Websites (Extended Search)

8: Work with the building owner to complete the ENERGY STAR 8: Work with the building owner to complete the ENERGY STAR lifecycle Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In this section Why you should design to earn the ENERGY STAR Follow EPA's step-by-step process Step 1: Assemble a team Step 2: Set an energy performance target Step 3: Evaluate your target using ENERGY STAR tools Step 4: Design to be energy efficient

176

Secretaries Chu and Donovan to Host Conference Call on Home Owners  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Donovan to Host Conference Call on Home Owners Donovan to Host Conference Call on Home Owners Energy-Saving Improvements Program Secretaries Chu and Donovan to Host Conference Call on Home Owners Energy-Saving Improvements Program April 20, 2011 - 12:00am Addthis WASHINGTON - Thursday, April 21st, U.S. Department of Energy Secretary Steven Chu and U.S. Housing and Urban Development Secretary Shaun Donovan will launch a new pilot program intended to offer homeowners low-cost financing to help make their homes more energy efficient. The Federal Housing Administration's (FHA) new PowerSaver Program will offer homeowners up to $25,000 to finance the installation of insulation, duct sealing, replacement doors and windows, HVAC systems, water heaters, solar panels, and geothermal systems. Donovan and Chu will speak with reporters following a tour of a local

177

A comparison of noxious facilities` impacts for home owners versus renters  

SciTech Connect

The siting of noxious facilities, such as hazardous waste facilities, is often vigorously opposed by local residents. As a result, one would expect people`s residential and employment choices to reflect a desire to avoid proximity to such facilities. Ibis behavior would in turn affect labor and housing prices. One technique that has been employed to implicitly value impacts of noxious facilities is the intercity hedonic approach, which examines the wage and land rent differentials among cities that result from environmental amenities and disamenities. However, most of the research focus has been on the behavioral response of home owners as opposed to renters. Since these two groups of residents vary on numerous dimensions such as marital status, age, sex, and personal mobility, it would not be surprising to find different marginal valuations of local site characteristics. We use 1980 Census data to derive separate estimates for owners and renters of the implicit value placed on eight different types of noxious facilities. Although the magnitude of the responses of renters and owners to noxious facilities and other environmental characteristics varies, the signs are generally consistent. The differences in values between owners and renters are not primarily due to differential mobility or sociodemographic factors. Controlling those factors decreases the differences between renters` and owners` implicit valuations by less than 10%. Unmeasured differences in characteristics between the two groups, such as tastes, risk aversion, or commitment to the community, must account for the remaining difference in valuations. These findings suggest that policymakers should separately consider the responses of owners and renters when estimating noxious facility impacts.

Clark, D.E. [Marquette Univ., Milwaukee, WI (United States). Dept. of Economics]|[Argonne National Lab., IL (United States); Nieves, L.A. [Argonne National Lab., IL (United States)

1996-09-01T23:59:59.000Z

178

Steam Generator Management Program: Assessment of Steam Generator Tube Plugs  

Science Conference Proceedings (OSTI)

EPRI Steam Generator Management Program guidelines require that utilities perform integrity assessments of all steam generator (SG) components, including tube plugs. SG inspection outages should specifically include monitoring of degradation in tube hardware such as plugs. This report provides guidance for utility engineers to use in determining tube plug inspection requirements, including scope, technique, and periodicity.BackgroundGenerally, utilities perform ...

2013-08-28T23:59:59.000Z

179

Turbocompressor downhole steam-generating system  

SciTech Connect

This patent describes a downhole steam-generating system comprising: an air compressor; a steam generating unit, including: a combustor for combusting fuel with the compressed air from the compressor producing combustor exhaust products; and steam conversion means, in indirect heat-exchange relationship with the combustor, for converting water which is fed into the steam-conversion means into steam; a turbine which is rotated by the combustor exhaust products and steam from the steam-generating unit, the rotational motion of the turbine is mechanically coupled to the air compressor to drive the air compressor; and control bypass means associated with the steam generating unit and turbine for regulating the relative amounts of the combustor exhaust product and steam delivered to the turbine from the steam generating unit. The air compressor and turbine form an integral turbocompressor unit. The turbocompressor unit, steam-generating unit and control bypass means are located downhole during operation of the steam-generating system.

Wagner, W.R.

1987-07-28T23:59:59.000Z

180

Benchmark the Fuel Cost of Steam Generation  

DOE Green Energy (OSTI)

BestPractices Steam tip sheet regarding ways to assess steam system efficiency. To determine the effective cost of steam, use a combined heat and power simulation model that includes all the significant effects.

Papar, R. [U.S. Department of Energy (US)

2000-12-04T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

High Efficiency Steam Electrolyzer  

SciTech Connect

A novel steam electrolyzer has been developed. In conventional electrolyzers, oxygen produced from electrolysis is usually released in the air stream. In their novel design, natural gas is used to replace air in order to reduce the chemical potential difference across the electrolyzer, thus minimizing the electrical consumption. The oxygen from the electrolysis is consumed in either a total oxidation or a partial oxidation reaction with natural gas. Experiments performed on single cells shown a voltage reduction as much as 1 V when compared to conventional electrolyzers. Using thin film materials and high performance cathode and anode, electrolysis could be done at temperatures as low as 700 C with electrolytic current as high as 1 A/cm{sup 2} at a voltage of 0.5 V only. The 700 C operating temperature is favorable to the total oxidation of natural gas while minimizing the need for steam that is otherwise necessary to avoid carbon deposition. A novel tubular electrolyzer stack has been developed. The system was designed to produce hydrogen at high pressures, taking advantage of the simplicity and high efficiency of the electrochemical compressors. A complete fabrication process was developed for making electrolyzer tubes with thin film coatings. A 100 W stack is being built.

Pham, A.Q.

2000-06-19T23:59:59.000Z

182

Cogeneration for industrial and mixed-use parks. Volume 3. A guide for park developers, owners, and tenants. Final report  

SciTech Connect

Using cogeneration in mixed-use and industrial parks can cut energy costs ad smooth out peak load demands - benefits for servicing utilities and park owners and tenants. The two handbooks developed by this project can help utilities identify existing or planned parks as potential cogeneration sites as well as help developers and park owners evaluate the advantages of cogeneration. The second handbook (volume 3) describes the benefits of cogeneration for park developers, owners, and tenants.

Schiller, S.R.; Minicucci, D.D.; Tamaro, R.F.

1986-05-01T23:59:59.000Z

183

Reduction in Unit Steam Production  

E-Print Network (OSTI)

In 2001 the company's Arch-Brandenburg facility faced increased steam costs due to high natural gas prices and decreased production due to shutdown of a process. The facility was challenged to reduce unit steam consumption to minimize the effects of thes

Gombos, R.

2004-01-01T23:59:59.000Z

184

Go Steam for Green Transportation  

Science Conference Proceedings (OSTI)

Railroads are very fuel-efficient in moving freight by land. The history of rail begins with steam power, moving to eventual dieselization. Some components, advantages and disadvantages of internal combustion engines (gasoline, diesel) and external combustion ... Keywords: diesel engine, steam engine, biocoal, biofuel, computer control, internal combustion, external combustion

Paul Fred Frenger

2013-04-01T23:59:59.000Z

185

Hartford Steam Co | Open Energy Information  

Open Energy Info (EERE)

Edit with form History Share this page on Facebook icon Twitter icon Hartford Steam Co Jump to: navigation, search Name Hartford Steam Co Place Connecticut Utility Id...

186

Combustion gas turbine/steam generator plant  

SciTech Connect

A fired steam generator is described that is interconnected with a gas turbine/steam generator plant having at least one gas turbine group followed by an exhaust-gas steam generator. The exhaust-gas steam generator has a preheater and an evaporator. The inlet of the preheater is connected to a feedwater distribution line which also feeds a preheater in the fired steam generator. The outlet of the preheater is connected to the evaporator of the fired steam generator. The evaporator outlet of the exhaust-gas steam generator is connected to the input of a superheater in the fired steam generator.

Aguet, E.

1975-11-18T23:59:59.000Z

187

Steam Basics: Use Available Data to Lower Steam System Cost  

E-Print Network (OSTI)

Industrial steam users recognize the need to reduce system cost in order to remain internationally competitive. Steam systems are a key utility that influence cost significantly, and represent a high value opportunity target. However, the quality of steam is often taken for granted, even overlooked at times. When the recent global recession challenged companies to remain profitable as a first priority, the result was that maintenance budgets were cut and long term cost reduction initiatives for steam systems set aside due to more pressing issues. One of the regrettable results of such actions is that knowledgeable personnel are re-assigned, retired, or released when necessary steam system cost reduction programs are eliminated. When the time arrives to refocus on long term cost reduction by improving the steam system, some programs may have to start from the beginning and a clear path forward may not be evident. New personnel are often tasked with steam improvements when the programs restart, and they may experience difficulty in determining the true key factors that can help reduce system cost. The urgency for lowering long term fuel use and reducing the cost of producing steam is near for each plant. Population growth and resultant global demand are inevitable, so the global economy will expand, production will increase, more fossil fuel energy will be needed, and that fuel will become scarce and more costly. Although fuel prices are low now, energy costs can be expected to trend significantly upward as global production and demand increase. Now is the time for plants to make certain that they can deliver high quality steam to process equipment at lowest system cost. There are three stages to help optimize plant steam for best performance at a low system cost; Phase 1: Manage the condensate discharge locations (where the steam traps & valves are located), Phase 2: Optimize steam-using equipment, and Phase 3: Optimize the entire steam system. This presentation will focus primarily on management of the condensate discharge locations (CDLs) and show sites how to use readily available data to more efficiently achieve goals; but will also provide insight into how the three stages interact to reduce system cost and improve process performance.

Risko, J. R.

2011-01-01T23:59:59.000Z

188

Evaluate deaerator steam requirements quickly  

Science Conference Proceedings (OSTI)

Steam plant engineers frequently have to perform energy balance calculations around the deaerator to estimate the steam required to preheat and deaerate the make-up water and condensate returns. This calculation involves solving two sets of equations, one for mass and the other for energy balance. Reference to steam tables is also necessary. However, with the help of this program written in BASIC, one can arrive at the make-up water and steam requirements quickly, without referring to steam tables. This paper shows the mass and energy balance equations for the deaerator. This paper gives the program listing. An number of condensate returns can be handled. An example illustrates the use of the program.

Ganapathy, V. (ABCO Industries, Inc., Abilene, TX (US))

1991-02-01T23:59:59.000Z

189

Further experimental studies of steam-propane injection to enhance recovery of Morichal oil  

E-Print Network (OSTI)

In 1998-1999, experimental research was conducted by Goite at Texas A&M University into steam-propane injection to enhance oil recovery from the Morichal field, Venezuela. Goite's results showed that, compared with steam injection alone, steam-propane injection accelerated oil production by as much as 23 % pore volume of steam injected (cold-water equivalent). The apparatus and procedure used in this study have been improved. Steam injection rate was kept constant at 5 cc/min (cold-water equivalent) for all runs. Four thermocouples were placed along the longitudinal axis of the cell to measure temperature profiles during injection. A new, more efficient method was developed to break emulsion in the produced sample. For four of the eight runs, consistent operating conditions were obtained by use of superheated steam, cell pressure of 50 psig, and identical insulation. Eight experimental runs were made in which the propane:steam mass ratios used were 0:100 (steam only), 1:100, 2.5:100, and 5:100. A run using 5:100 nitrogen: steam mass ratio was also made. The main findings of this research (derived from four runs with consistent operating conditions) are as follows. First, the propane:steam mass ratio of 5:100 accelerated the start and peak of oil production by 20 % and 13 % pore volume steam injected (cold-water equivalent), compared to steam injection alone. Second, oil recoveries for practical purposes are similar in all cases, 63 % - 70 % OOIP if average high and low values are taken. Third, the start of production is practically the same for 0:100 and 1:100 propane:steam ratio and for 5:100 nitrogen: steam ratio. In the latter case, the production peak is higher due to additional drive from nitrogen injection. Fourth, oil production acceleration in the 5:100 propane:steam case is probably caused by dry distillation in which light fractions of the oil partition into and are carried by the injected propane to lower the viscosity of the oil ahead of the steam front. Last, convective heat transfer at any of these low (5:100) ratios appears to be of secondary importance.

Ferguson,Mark Anthony

2000-01-01T23:59:59.000Z

190

ULTRA-SUPERCRITICAL STEAM CORROSION  

SciTech Connect

Efficiency increases in fossil energy boilers and steam turbines are being achieved by increasing the temperature and pressure at the turbine inlets well beyond the critical point of water. To allow these increases, advanced materials are needed that are able to withstand the higher temperatures and pressures in terms of strength, creep, and oxidation resistance. As part of a larger collaborative effort, the Albany Research Center (ARC) is examining the steam-side oxidation behavior for ultrasupercritical (USC) steam turbine applications. Initial tests are being done on six alloys identified as candidates for USC steam boiler applications: ferritic alloy SAVE12, austenitic alloy Super 304H, the high Cr-high Ni alloy HR6W, and the nickel-base superalloys Inconel 617, Haynes 230, and Inconel 740. Each of these alloys has very high strength for its alloy type. Three types of experiments are planned: cyclic oxidation in air plus steam at atmospheric pressure, thermogravimetric ana lysis (TGA) in steam at atmospheric pressure, and exposure tests in supercritical steam up to 650 C (1202 F) and 34.5 MPa (5000 psi). The atmospheric pressure tests, combined with supercritical exposures at 13.8, 20.7, 24.6, and 34.5 MPa (2000, 3000, 4000, and 5000 psi) should allow the determination of the effect of pressure on the oxidation process.

Holcomb, G.R.; Alman, D.E.; Bullard, S.B.; Covino, B.S., Jr.; Cramer, S.D.; Ziomek-Moroz, M.

2003-04-22T23:59:59.000Z

191

Steam reformer with catalytic combustor  

DOE Patents (OSTI)

A steam reformer is disclosed having an annular steam reforming catalyst bed formed by concentric cylinders and having a catalytic combustor located at the center of the innermost cylinder. Fuel is fed into the interior of the catalytic combustor and air is directed at the top of the combustor, creating a catalytic reaction which provides sufficient heat so as to maintain the catalytic reaction in the steam reforming catalyst bed. Alternatively, air is fed into the interior of the catalytic combustor and a fuel mixture is directed at the top. The catalytic combustor provides enhanced radiant and convective heat transfer to the reformer catalyst bed.

Voecks, Gerald E. (La Crescenta, CA)

1990-03-20T23:59:59.000Z

192

GCFR steam generator conceptual design  

SciTech Connect

The gas-cooled fast reactor (GCFR) steam generators are large once-through heat exchangers with helically coiled tube bundles. In the GCFR demonstration plant, hot helium from the reactor core is passed through these units to produce superheated steam, which is used by the turbine generators to produce electrical power. The paper describes the conceptual design of the steam generator. The major components and functions of the design are addressed. The topics discussed are the configuration, operating conditions, design criteria, and the design verification and support programs.

Holm, R.A.; Elliott, J.P.

1980-01-01T23:59:59.000Z

193

Hot Dry Rock - Summary  

SciTech Connect

Hot Dry Rock adds a new flexibility to the utilization of geothermal energy. Almost always the approach has been to limit that utilization to places where there is a natural source of water associated with a source of heat. Actually, the result was that steam was mined. Clearly there are much larger heat resources available which lack natural water to transport that energy to the surface. Also, as is found in hydrothermal fields being mined for steam, the water supply finally gets used up. There is a strong motive in the existing capital investment to revitalize those resources. Techniques for introducing, recovering and utilizing the water necessary to recover the heat from below the surface of the earth is the subject of this session. Implicit in that utilization is the ability to forecast with reasonable accuracy the busbar cost of that energy to the utility industry. The added element of supplying the water introduces costs which must be recovered while still supplying energy which is competitive. Hot Dry Rock technology can supply energy. That has been proved long since. The basic barrier to its use by the utility industry has been and remains proof to the financial interests that the long term cost is competitive enough to warrant investment in a technology that is new to utility on-grid operations. As the opening speaker for this session states, the test that is underway will ''simulate the operations of a commercial facility in some ways, but it will not show that energy from HDR can be produced at a variety of locations with different geological settings''. Further, the Fenton Hill system is a research facility not designed for commercial production purposes, but it can give indications of how the system must be changed to provide economic HDR operations. And so it is that we must look beyond the long term flow test, at the opportunities and challenges. Proving that the huge HDR resources can be accessed on a worldwide scale must involve the construction of additional sites, preferably to the specifications of the now Federal geothermal community. These facilities will have to be engineered to produce and market energy at competitive prices. At the same time, we must not rest on our technological laurels, though they be many. Design and operational techniques have been conceived which could lead to improved economics and operations for HDR. These must be pursued and where merit is found, vigorously pursued. Accelerated research and development ought to include revolutionary drilling techniques, reservoir interrogation, and system modeling to assure the competitiveness and geographical diversity of applications of HDR. Much of this work will be applicable to the geothermal industry in general. More advanced research ought to include such innovations as the utilization of other operating fluids. Supercritical carbon dioxide and the ammonia/water (Kalina) cycle have been mentioned. But even as the near and more distant outlook is examined, today's work was reported in the HDR session. The start-up operations for the current test series at the Fenton Hill HDR Pilot Plant were described. The surface plant is complete and initial operations have begun. While some minor modifications to the system have been required, nothing of consequence has been found to impede operations. Reliability, together with the flexibility and control required for a research system were shown in the system design, and demonstrated by the preliminary results of the plant operations and equipment performance. Fundamental to the overall success of the HDR energy resource utilization is the ability to optimize the pressure/flow impedance/time relationships as the reservoir is worked. Significant new insights are still being developed out of the data which will substantially affect the operational techniques applied to new systems. However, again, these will have to be proved to be general and not solely specific to the Fenton Hill site. Nevertheless, high efficiency use of the reservoir without unintended reservoir grow

Tennyson, George P. Jr.

1992-03-24T23:59:59.000Z

194

Steam Generator Management Program: Steam Generator Integrity Assessment Guidelines  

Science Conference Proceedings (OSTI)

This report provides guidance for evaluating the condition of steam generator (SG) tubes based on nondestructive examination (NDE) or in situ pressure testing. The integrity assessments are normally performed during a reactor refueling outage. Nuclear power plant licensees who follow the guidance in this report will have satisfied the requirements for degradation assessments, condition monitoring, and operational assessment as defined in the Nuclear Energy Institute (NEI) Steam Generator Program Guidelin...

2009-11-19T23:59:59.000Z

195

Wet-steam erosion of steam turbine disks and shafts  

SciTech Connect

A study of wet-steam erosion of the disks and the rotor bosses or housings of turbines in thermal and nuclear power plants shows that the rate of wear does not depend on the diagrammed degree of moisture, but is determined by moisture condensing on the surfaces of the diaphragms and steam inlet components. Renovating the diaphragm seals as an assembly with condensate removal provides a manifold reduction in the erosion.

Averkina, N. V. [JSC 'NPO TsKTI' (Russian Federation); Zheleznyak, I. V. [Leningradskaya AES branch of JSC 'Kontsern Rosenergoatom' (Russian Federation); Kachuriner, Yu. Ya.; Nosovitskii, I. A.; Orlik, V. G., E-mail: orlikvg@mail.ru [JSC 'NPO TsKTI' (Russian Federation); Shishkin, V. I. [Leningradskaya AES branch of JSC 'Kontsern Rosenergoatom' (Russian Federation)

2011-01-15T23:59:59.000Z

196

Steam Generator Management Program: Steam Generator Progress Report: Revision 18  

Science Conference Proceedings (OSTI)

BackgroundSince 1985, the Electric Power Research Institute (EPRI) has published the Steam Generator Progress Report (SGPR), which provides historical information on worldwide steam generator activities. This document was published once a year and distributed via hardcopy. Until 1998, the method of acquiring data for this report had been to issue annual survey forms to all PWR and pressurized heavy water reactor nuclear utilities worldwide. The information included in ...

2013-11-20T23:59:59.000Z

197

Steam Plant Conversion Eliminating Campus Coal Use  

E-Print Network (OSTI)

Steam Plant Conversion Eliminating Campus Coal Use at the Steam Plant #12;· Flagship campus region produce 14% of US coal (TN only 0.2%) Knoxville and the TN Valley #12;· UT is one of about 70 U.S. colleges and universities w/ steam plant that burns coal · Constructed in 1964, provides steam for

Dai, Pengcheng

198

Combined Heat and Power Plant Steam Turbine  

E-Print Network (OSTI)

waste heat) Gas Turbine University Substation High Pressure Natural Gas Campus Electric Load SouthernCombined Heat and Power Plant Steam Turbine Steam Turbine Chiller Campus Heat Load Steam (recovered Generator Heat Recovery Alternative Uses: 1. Campus heating load 2. Steam turbine chiller to campus cooling

Rose, Michael R.

199

Steam distillation effect and oil quality change during steam injection  

SciTech Connect

Steam distillation is an important mechanism which reduces residual oil saturation during steam injection. It may be the main recovery mechanism in steamflooding of light oil reservoirs. As light components are distilled the residual (initial) oil, the residuum becomes heavier. Mixing the distilled components with the initial oil results in a lighter produced oil. A general method has been developed to compute steam distillation yield and to quantify oil quality changes during steam injection. The quantitative results are specific because the California crude data bank was used. But general principles were followed and calculations were based on information extracted from the DOE crude oil assay data bank. It was found that steam distillation data from the literature can be correlated with the steam distillation yield obtained from the DOE crude oil assays. The common basis for comparison was the equivalent normal boiling point. Blending of distilled components with the initial oil results in API gravity changes similar to those observed in several laboratory and field operations.

Lim, K.T.; Ramey, H.J. Jr.; Brigham, W.E.

1992-01-01T23:59:59.000Z

200

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network (OSTI)

: Introduction, Steam Generation Efficiency Resource Utilization Analysis, and Steam Distribution System Losses Stack Losses Resource Utilization Analysis Steam Distribution System Losses Conclusion Quiz If youDOE's BestPractices Steam End User Training Steam End User Training Navigational Tutorial - 1 8

Oak Ridge National Laboratory

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network (OSTI)

horizontal runs of steam distribution piping from a common header. Steam distribution piping is insulatedDOE's BestPractices Steam End User Training Steam End User Training Introduction Module - 1 8/27/2010 Steam End User Training Introduction Module Slide 1 - Introduction Title Page Hello, and welcome

Oak Ridge National Laboratory

202

Steam turbine for geothermal power generation  

SciTech Connect

A steam turbine comprises a casing; turbine vanes rotatably set in the casing; a plurality of partition walls which extend along radial directions from the rotation center of the turbine vanes to define a plurality of steam valve chambers in the casing; steam supply pipes respectively connected to the corresponding steam valve chambers; and regulating valves which are fitted to the respective steam supply pipes to regulate respectively the flow rate of steam streams supplied to the respective steam valve chambers. At least one partition wall for dividing the interior space of the steam turbine into adjacent steam valve chambers is provided with at least one penetrating hole for causing the steam valve chambers to communicate with each other.

Tsujimura, K.; Hadano, Y.

1984-04-10T23:59:59.000Z

203

Simplify heat recovery steam generator evaluation  

SciTech Connect

Heat recovery steam generators (HRSGs) are widely used in process and power plants, refineries and in several cogeneration/combined cycle systems. They are usually designed for a set of gas and steam conditions but often operate under different parameters due to plant constraints, steam demand, different ambient conditions (which affect the gas flow and exhaust gas temperature in a gas turbine plant), etc. As a result, the gas and steam temperature profiles in the HRSG, steam production and the steam temperature differ from the design conditions, affecting the entire plant performance and economics. Also, consultants and process engineers who are involved in evaluating the performance of the steam system as a whole, often would like to simulate the performance of an HRSG under different gas flows, inlet gas temperature and analysis, steam pressure and feed water temperature to optimize the entire steam system and select proper auxiliaries such as steam turbines, condensers, deaerators, etc.

Ganapathy, V. (ABCO Industries, Abilene, TX (US))

1990-03-01T23:59:59.000Z

204

Steam Field | Open Energy Information  

Open Energy Info (EERE)

Field Field Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Sanyal Temperature Classification: Steam Field Dictionary.png Steam Field: No definition has been provided for this term. Add a Definition Sanyal Temp Classification This temperature scheme was developed by Sanyal in 2005 at the request of DOE and GEA, as reported in Classification of Geothermal Systems: A Possible Scheme. Extremely Low Temperature Very Low Temperature Low Temperature Moderate Temperature High Temperature Ultra High Temperature Steam Field Steam field reservoirs are special cases where the fluid is predominantly found in a gas phase between 230°C to 240°C. "This special class of resource needs to be recognized, its uniqueness being the remarkably consistent initial temperature and pressure

205

The Elimination of Steam Traps  

E-Print Network (OSTI)

How would you like to have a share of $154,000,000,000 a year? According to the Department of Energy that is roughly what was spent for creating steam in 1978. Steam generation accounts for fully one half of the industrial and commercial energy dollar. That figure could be reduced by 10-20% or more by the simple elimination of steam traps. Recent engineering developments show that steam traps can be eliminated. Documented results demonstrate that the retrofitting of existing facilities to alternative methods of condensate removal is simple and economically feasible, with paybacks of less than 12 months. Advantages obtained in the first year remain consistent for several years after conversion with virtual elimination of maintenance.

Dickman, F.

1985-05-01T23:59:59.000Z

206

Computer Optimization of Steam Production  

E-Print Network (OSTI)

As fuel costs continued to rise sharply during the 1970' s, the staff at Exxon's Benicia Refinery realized there was a growing economic incentive to optimize the production of high pressure steam. A significant percentage of the Refinery's total energy is consumed in generating high pressure steam. Recently, a computer program was implemented to optimize high pressure steam production. The first challenge in developing the program was to provide reliable analog and digital instrumentation allowing simultaneous analog header control along with effective digital steam flow control. Once appropriate instrumentation became available, the effort focused on identifying the best approach for developing the computer control program. After screening several alternatives, it became apparent that we were dealing with an allocation problem which could be effectively handled with a linear program. The control program has performed well since it was commissioned. It has experienced a service factor of greater than 95% while reducing energy consumption of the boilers by over 500 million Btu's per day.

Todd, C. H.

1982-01-01T23:59:59.000Z

207

The steam engine and industrialization  

E-Print Network (OSTI)

Simon Schaffer in York Rail Museum talks to the camera about the relationship between the steam engine and industrialization and whatsteam meant; a regular supply of moving power for workshops and factories....

Dugan, David

2004-08-17T23:59:59.000Z

208

Heat Recovery Steam Generator Simulation  

E-Print Network (OSTI)

The paper discusses the applications of Heat Recovery Steam Generator Simulation. Consultants, plant engineers and plant developers can evaluate the steam side performance of HRSGs and arrive at the optimum system which matches the needs of the process plant, cogeneration or combined cycle plant. There is no need to design the HRSG per se and hence simulation is a valuable tool for anyone interested in evaluating the HRSG performance even before it is designed. It can also save a lot of time for specification writers as they need not guess how the steam side performance will vary with different gas/steam parameters. A few examples are given to show how simulation methods can be applied to real life problems.

Ganapathy, V.

1993-03-01T23:59:59.000Z

209

Steam Generator Management Program: Flaw Handbook Calculator  

Science Conference Proceedings (OSTI)

The EPRI Steam Generator Management Program: Steam Generator Degradation Specific Flaw Handbook v1.0 defines burst pressure equations for steam generator tubes with various degradation morphologies, and the EPRI Steam Generator Management Program: Steam Generator Integrity Assessment Guidelines (1019038) describes a probabilistic evaluation process which can be used to account for key input parameter uncertainties. The Flaw Handbook Calculator software is an automated Microsoft Excelspreadsheet which cal...

2010-04-20T23:59:59.000Z

210

Steam turbine gland seal control system  

SciTech Connect

A high pressure steam turbine having a sealing gland where the turbine rotor penetrates the casing of the turbine. Under certain conditions the gland is sealed by an auxiliary steam supply, and under other conditions the gland is self sealed by turbine inlet steam. A control system is provided to modify the temperature of the auxiliary steam to be more compatible with the self sealing steam, so as to eliminate thermal shock to the turbine rotor.

Martin, H. F.

1985-09-17T23:59:59.000Z

211

Field Guide: Turbine Steam Path Damage  

Science Conference Proceedings (OSTI)

Steam path damage, particularly of blades, has long been recognized as a leading cause of steam turbine unavailability for large fossil fuel plants. Damage to steam path components by various mechanisms continues to result in significant economic impact domestically and internationally. Electric Power Research Institute (EPRI) Report TR-108943, Turbine Steam Path Damage: Theory and Practice, Volumes 1 and 2, was prepared to compile the most recent knowledge about turbine steam path damage: identifying th...

2011-12-12T23:59:59.000Z

212

Steam Generator Integrity Assessment Guidelines  

Science Conference Proceedings (OSTI)

This report provides guidance for evaluating the condition of steam generator (SG) tubes based on nondestructive examination (NDE) or in situ pressure testing. This integrity assessment is normally performed during a reactor refueling outage. Nuclear power plant licensees who follow this document's guidelines will have satisfied their requirements for condition monitoring and operational assessment as defined in the Nuclear Energy Institute (NEI) initiative, Steam Generator Program Guidelines, NEI 97-06.

2006-07-25T23:59:59.000Z

213

Facility Name Facility Name Facility FacilityType Owner Developer EnergyPurchaser  

Open Energy Info (EERE)

Name Facility Name Facility FacilityType Owner Developer EnergyPurchaser Name Facility Name Facility FacilityType Owner Developer EnergyPurchaser Place GeneratingCapacity NumberOfUnits CommercialOnlineDate WindTurbineManufacturer FacilityStatus Coordinates D Metals D Metals D Metals Definition Small Scale Wind Valley City OH MW Northern Power Systems In Service AB Tehachapi Wind Farm AB Tehachapi Wind Farm AB Tehachapi Definition Commercial Scale Wind Coram Energy AB Energy Southern California Edison Co Tehachapi CA MW Vestas In Service AFCEE MMR Turbines AFCEE MMR Turbines AFCEE MMR Turbines Definition Commercial Scale Wind AFCEE Air Force Center for Engineering and the Environment Distributed generation net metered Camp Edwards Sandwich MA MW GE Energy In Service AG Land AG Land AG Land Definition Community Wind AG Land Energy LLC

214

Solar PV Project Financing: Regulatory and Legislative Challenges for Third-Party PPA System Owners (Revised)  

NLE Websites -- All DOE Office Websites (Extended Search)

23 23 Revised February 2010 Solar PV Project Financing: Regulatory and Legislative Challenges for Third-Party PPA System Owners Katharine Kollins Duke University Bethany Speer and Karlynn Cory National Renewable Energy Laboratory National Renewable Energy Laboratory 1617 Cole Boulevard, Golden, Colorado 80401-3393 303-275-3000 * www.nrel.gov NREL is a national laboratory of the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Operated by the Alliance for Sustainable Energy, LLC Contract No. DE-AC36-08-GO28308 Technical Report NREL/TP-6A2-46723 Revised February 2010 Solar PV Project Financing: Regulatory and Legislative Challenges for Third-Party PPA System Owners Katharine Kollins Duke University Bethany Speer and Karlynn Cory

215

CDQ System Designing and Dual-Loop PID Tuning Method for Air Steam Temperature  

Science Conference Proceedings (OSTI)

In this paper, we mainly introduce the key technology of a steel plant's CDQ(Coke Dry Quenching) control system design based on PLC (Programmable LogicController). The CDQ control system is divided into five systems which are as follows: the coke loading, ... Keywords: CDQ system, steam temperature control, Dualloop PID Tuning, environment protecting

Gao Jian, Chen Xianqiao

2013-09-01T23:59:59.000Z

216

Development and Application of Advanced Models for Steam Hydrogasification: Process Design and Economic Evaluation  

E-Print Network (OSTI)

to make additional steam for the steam turbine cycle. Thein multi-pressure-level steam turbines to produce additionalthe superheated steam to the steam turbine cycle. The most

Lu, Xiaoming

2012-01-01T23:59:59.000Z

217

Dynamic underground stripping: steam and electric heating for in situ decontamination of soils and groundwater  

SciTech Connect

A dynamic underground stripping process removes localized underground volatile organic compounds from heterogeneous soils and rock in a relatively short time. This method uses steam injection and electrical resistance heating to heat the contaminated underground area to increase the vapor pressure of the contaminants, thus speeding the process of contaminant removal and making the removal more complete. The injected steam passes through the more permeable sediments, distilling the organic contaminants, which are pumped to the surface. Large electrical currents are also applied to the contaminated area, which heat the impermeable subsurface layers that the steam has not penetrated. The condensed and vaporized contaminants are withdrawn by liquid pumping and vacuum extraction. The steam injection and electrical heating steps are repeated as necessary. Geophysical imaging methods can be used to map the boundary between the hot, dry, contamination-free underground zone and the cool, damp surrounding areas to help monitor the dynamic stripping process.

Daily, William D. (Livermore, CA); Ramirez, Abelardo L. (Pleasanton, CA); Newmark, Robin L. (Pleasanton, CA); Udell, Kent (Berkeley, CA); Buetnner, Harley M. (Livermore, CA); Aines, Roger D. (Livermore, CA)

1995-01-01T23:59:59.000Z

218

Dynamic underground stripping: steam and electric heating for in situ decontamination of soils and groundwater  

DOE Patents (OSTI)

A dynamic underground stripping process removes localized underground volatile organic compounds from heterogeneous soils and rock in a relatively short time. This method uses steam injection and electrical resistance heating to heat the contaminated underground area to increase the vapor pressure of the contaminants, thus speeding the process of contaminant removal and making the removal more complete. The injected steam passes through the more permeable sediments, distilling the organic contaminants, which are pumped to the surface. Large electrical currents are also applied to the contaminated area, which heat the impermeable subsurface layers that the steam has not penetrated. The condensed and vaporized contaminants are withdrawn by liquid pumping and vacuum extraction. The steam injection and electrical heating steps are repeated as necessary. Geophysical imaging methods can be used to map the boundary between the hot, dry, contamination-free underground zone and the cool, damp surrounding areas to help monitor the dynamic stripping process. 4 figs.

Daily, W.D.; Ramirez, A.L.; Newmark, R.L.; Udell, K.; Buetnner, H.M.; Aines, R.D.

1995-09-12T23:59:59.000Z

219

Steam gasification of wood in the presence of catalysts  

SciTech Connect

Catalytic steam gasification of wood, including sawdust, chipped forest slash, and mill shavings, is being investigated. Results of laboratory, process development unit (PDU), and feasibility studies illustrate attractive processes for conversion of wood to methanol and a substitute natural gas (SNG). Recent laboratory studies developed a long-lived alloy catalyst for generation of a methanol synthesis gas by steam gasification of wood. Modification of the PDU for operation at 10 atm (150 psia) is nearly complete. The modified PDU will be operated at the elevated pressure to confirm yields and design parameters used in process feasibility studies. Feasibility studies were completed on wood-to-methane (SNG) and wood-to-methanol plants with capacities of 2000 and 200 oven dried tons (1800 and 180 metric t) per day using catalytic gasification. The results showed that generation of methanol on the large scale is economically viable today while SNG generation is competitive with future prices.

Mitchell, D.H.; Mudge, L.K.; Baker, E.G.

1981-01-01T23:59:59.000Z

220

Data Quality Evaluation of Hazardous Air Pollutants Measurements for the US Environmental Protection Agency's Electric Utility Steam Generating Units Information Collection Request  

Science Conference Proceedings (OSTI)

In December 2009, the U.S. Environmental Protection Agency (EPA) issued an Information Collection Request (ICR) to owners of fossil fuel-fired, electric steam generating units. Part III of the ICR required that almost 500 selected power plant stacks be tested for emissions of four groups of substances classified as hazardous air pollutants under the Clean Air Act: acid gases and hydrogen cyanide; metals; volatile and semivolatile organics; and polychlorinated dibenzodioxins, dibenzofurans, and polychlori...

2010-12-18T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

ProSteam- A Structured Approach to Steam System Improvement  

E-Print Network (OSTI)

Optimal operation of site utility systems is becoming an increasingly important part of any successful business strategy as environmental, legislative and commercial pressures grow. A reliable steam model allows a clear understanding of the system and of any operational constraints. It can also be used to determine the true cost of improvement projects, relating any changes in steam demand back to purchased utilities (fuel, power, and make-up water) at the site boundary. Example projects could include improved insulation, better condensate return, increased process integration, new steam turbines or even the installation of gas-turbine based cogeneration. This approach allows sites to develop a staged implementation plan for both operational and capital investment projects in the utility system. Steam system models can be taken one step further and linked to the site DCS data to provide real-time balances and improve the operation of the system, providing an inexpensive but very effective optimizer. Such a model ensures that the steam system is set in the optimum manner to react to current utility demands, emissions regulations, equipment availability, fuel and power costs, etc. This optimization approach typically reduces day-to-day utility system operating costs by between 1% and 5% at no capital cost.

Eastwood, A.

2002-04-01T23:59:59.000Z

222

DOE BestPractices Steam End User Training  

E-Print Network (OSTI)

DOE BestPractices Steam End User Training Guide Alternate Text Narratives and Graphic will discuss fuel selection, steam demands, and cogeneration. The Steam Distribution System Losses module

Oak Ridge National Laboratory

223

Use Steam Jet Ejectors or Thermocompressors to Reduce Venting of Low-Pressure Steam  

SciTech Connect

Industrial Technologies Program's BestPractices tip sheet on improving efficiency of industrial steam systems by recovery latent heat from low-pressure steam.

2005-09-01T23:59:59.000Z

224

Use Steam Jet Ejectors or Thermocompressors to Reduce Venting of Low-Pressure Steam  

SciTech Connect

Industrial Technologies Program's BestPractices tip sheet on improving efficiency of industrial steam systems by recovery latent heat from low-pressure steam.

Not Available

2005-09-01T23:59:59.000Z

225

Evaluation of UHT milk processed by direct steam injection and steam infusion technology.  

E-Print Network (OSTI)

??UHT direct steam injection and steam infusion are widely used; however there is no comparison of their impact on milk components. This study evaluates the… (more)

Malmgren, Bozena

2007-01-01T23:59:59.000Z

226

Change steam tapping to save energy  

SciTech Connect

Induction turbines are common in large plants. They use both high pressure (HP) and low pressure (LP) steam and exhaust into a surface condenser operating under vacuum. Induction turbines are especially useful since they use maximum available LP steam with a balanced amount of HP steam and thus, achieve the best overall thermodynamic efficiency. LP steam is generally available as flash steam for boiler blow down, exhausts from back pressure turbines, process waste-heat recovery, etc. Typically, an LP steam header is routed around the plant with several connections to receive and supply steam. Therefore, it is common to connect each steam user/supplier to the nearest point on the main header. The portion of the header where steam turbine exhausts are connected has superheated LP steam and the header portion which receives steam from waste heat recovery, boiler blow down, etc., has saturated LP steam. Some portion of the header has mixed steam. Thus, the temperature of LP steam in the header varies over its length.

Antony, S.M.; Joshi, G.C.

1987-07-01T23:59:59.000Z

227

Steam Pressure Reduction, Opportunities, and Issues  

Science Conference Proceedings (OSTI)

Steam pressure reduction has the potential to reduce fuel consumption for a minimum capital investment. When the pressure at the boiler is reduced, fuel and steam are saved as a result of changes in the high-pressure side of the steam system from the boiler through the condensate return system. In the boiler plant, losses from combustion, boiler blowdown, radiation, and steam venting from condensate receivers would be reduced by reducing steam pressure. Similarly, in the steam distribution system, losses from radiation, flash steam vented from condensate receivers, and component and steam trap leakage would also be reduced. There are potential problems associated with steam pressure reduction, however. These may include increased boiler carryover, boiler water circulation problems in watertube boilers, increased steam velocity in piping, loss of power in steam turbines, and issues with pressure reducing valves. This paper is based a Steam Technical Brief sponsored by the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy and Enbridge Gas Distribution, Inc. (5). An example illustrates the use of DOE BestPractices Steam System Assessment Tool to model changes in steam, fuel, electricity generation, and makeup water and to estimate resulting economic benefits.

Berry, Jan [ORNL; Griffin, Mr. Bob [Enbridge Gas Distribution, Inc.; Wright, Anthony L [ORNL

2006-01-01T23:59:59.000Z

228

CARBON DIOXIDE CAPTURE FROM FLUE GAS USING DRY REGENERABLE SORBENTS  

SciTech Connect

This report describes research conducted between April 1, 2004 and June 30, 2004 on the preparation and use of dry regenerable sorbents for removal of carbon dioxide from flue gas. Support materials and supported sorbents were prepared by spray drying. Sorbents consisting of 20 to 50% sodium carbonate on a ceramic support were prepared by spray drying in batches of approximately 300 grams. The supported sorbents exhibited greater carbon dioxide capture rates than unsupported calcined sodium bicarbonate in laboratory tests. Preliminary process design and cost estimation for a retrofit application suggested that costs of a dry regenerable sodium carbonate-based process could be lower than those of a monoethanolamine absorption system. In both cases, the greatest part of the process costs come from power plant output reductions due to parasitic consumption of steam for recovery of carbon dioxide from the capture medium.

David A. Green; Brian S. Turk; Jeffrey W. Portzer; Raghubir P. Gupta; William J. McMichael; Thomas Nelson

2004-07-01T23:59:59.000Z

229

Dry cooling tower operating experience in the LOFT reactor  

SciTech Connect

A dry cooling tower has been uniquely utilized to dissipate heat generated in a small experimental pressurized water nuclear reactor. Operational experience revealed that dry cooling towers can be intermittently operated with minimal wind susceptibility and water hammer occurrences by cooling potential steam sources after a reactor scram, by isolating idle tubes from the external atmosphere, and by operating at relatively high pressures. Operating experience has also revealed that tube freezing can be minimized by incorporating the proper heating and heat loss prevention features.

Hunter, J.A.

1980-01-01T23:59:59.000Z

230

Transporting Dry Ice  

NLE Websites -- All DOE Office Websites (Extended Search)

Requirements for Shipping Dry Ice IATA PI 904 Source: Reg of the Day from ERCweb 2006 Environmental Resource Center | 919-469-1585 | webmaster@ercweb.com http:...

231

Distribution of fluid phases within the steam zone in steam injection processes  

SciTech Connect

The saturation distribution of steam, water, and oil within the steam zone in a steam injection process at constant injection rates is examined. It is shown theoretically that for typical values of injection parameters the oil saturation in the steam zone rapidly reaches its residual value at steam zone conditions. This result, which corroborates previous experimental evidence, is a consequence of the relatively fast changes in phase saturations compared to the rate of the advance of the steam front. Explicit expressions for the steam saturation distribution are obtained. It is shown that the average steam saturation is a slightly decreasing function of time and approaches a limiting value which is a nearly constant fraction of the steam saturation at the injection point. This result provides theoretical justification for the often made assumption of constant average steam saturation in steam injection calculations.

Yortsos, Y.C.

1982-09-01T23:59:59.000Z

232

IMPROVEMENTS IN STEAM GENERATING PLANT AND AN IMPROVED METHOD OF GENERATING STEAM  

SciTech Connect

A steam generating plant, designed for heat transfer from a liquid metal (potassium, sodium, or their alloy) with reduced danger of explosion, is based on the fact that, if steam (especially superheated) rather than water contacts the liquid metal, the risk of explosion is much reduced. In this plant steam is superheated by heat transfer from liquid metal, the steam bsing generated by heat transfer between the superheated steam and water. Diagrams are given for the plant, which comprises a series of heat exchangers in which steam is superheated; part of the superheated steam is recycled to convert water into steam. Apart from the danger of a steam--liquid metal contact, the main danger is that the superheated steam might cool, coming to the saturated condition; this danger can be averted by setting up mceans for detecting low steam temperatures. (D.L.C.)

Zoller, R.E.

1960-09-01T23:59:59.000Z

233

NUCLEAR FLASH TYPE STEAM GENERATOR  

DOE Patents (OSTI)

A nuclear steam generating apparatus is designed so that steam may be generated from water heated directly by the nuclear heat source. The apparatus comprises a pair of pressure vessels mounted one within the other, the inner vessel containing a nuclear reactor heat source in the lower portion thereof to which water is pumped. A series of small ports are disposed in the upper portion of the inner vessel for jetting heated water under pressure outwardly into the atmosphere within the interior of the outer vessel, at which time part of the jetted water flashes into steam. The invention eliminates the necessity of any intermediate heat transfer medium and components ordinarily required for handling that medium. (AEC)

Johns, F.L.; Gronemeyer, E.C.; Dusbabek, M.R.

1962-09-01T23:59:59.000Z

234

Generating Steam by Waste Incineration  

E-Print Network (OSTI)

Combustible waste is a significant source of steam at the new John Deere Tractor Works assembly plant in Waterloo, Iowa. The incinerators, each rated to consume two tons of solid waste per hour, are expected to provide up to 100 percent of the full production process steam requirements. The waste incineration system consists of a wood dunnage shredder, two Skid-Steer Loaders for incinerator charging, two incinerators, and a wet ash conveyor. The equipment is housed in a building with floor space to accommodate loads of combustible waste delivered for incineration. Incombustible material is segregated at the source. A review of operational experience and the results of a study on actual steam production costs will be presented with the intent that others will be able to use the information to advance the state of the art of high volume controlled air waste incineration.

Williams, D. R.; Darrow, L. A.

1981-01-01T23:59:59.000Z

235

Fast fluidized bed steam generator  

DOE Patents (OSTI)

A steam generator in which a high-velocity, combustion-supporting gas is passed through a bed of particulate material to provide a fluidized bed having a dense-phase portion and an entrained-phase portion for the combustion of fuel material. A first set of heat transfer elements connected to a steam drum is vertically disposed above the dense-phase fluidized bed to form a first flow circuit for heat transfer fluid which is heated primarily by the entrained-phase fluidized bed. A second set of heat transfer elements connected to the steam drum and forming the wall structure of the furnace provides a second flow circuit for the heat transfer fluid, the lower portion of which is heated by the dense-phase fluidized bed and the upper portion by the entrained-phase fluidized bed.

Bryers, Richard W. (Flemington, NJ); Taylor, Thomas E. (Bergenfield, NJ)

1980-01-01T23:59:59.000Z

236

Optimized Control Of Steam Heating Coils  

E-Print Network (OSTI)

Steam has been widely used as the source of heating in commercial buildings and industries throughout the twentieth century. Even though contemporary designers have moved to hot water as the primary choice for heating, a large number of facilities still use steam for heating. Medical campuses with on-site steam generation and extensive distribution systems often serve a number of buildings designed prior to the mid-1980s. The steam is typically used for preheat as its high thermal content helps in heating the air faster and prevents coils from freezing in locations with extreme weather conditions during winter. The present work provides a comprehensive description of the various types of steam heating systems, steam coils, and valves to facilitate the engineer's understanding of these steam systems. A large percentage of the steam coils used in buildings are provided with medium pressure steam. Veterans Integrated Service Network and Army Medical Command Medical Facilities are examples which use medium pressure steam for heating. The current design manual for these medical facilities recommends steam at 30psig be provided to these coils. In certain cases although the steam heating coil is designed for a 5psig steam pressure, it is observed that higher pressure steam is supplied at the coil. A higher steam pressure may lead to excessive heating, system inefficiency due to increased heat loss, simultaneous heating and cooling, and increased maintenance cost. Field experiments were conducted to evaluate the effect of lowering steam pressure on the system performance. A 16% reduction in temperature rise across the coil was found when the steam pressure in the coil was reduced from 15psig to 5psig. The rise in temperature with lower pressure steam was sufficient to prevent coil freeze-up even in the most severe weather conditions. Additional benefits of reduced steam pressure are reduced flash steam losses (flash steam is vapor or secondary steam formed when hot condensate from the coil is discharged into a lower pressure area, i.e., the condensate return line) and radiation losses, increased flow of air through the coil thereby reducing air stratification and reduced energy losses in the event of actuator failure. The work also involved evaluating the existing control strategies for the steam heating system. New control strategies were developed and tested to address the short comings of existing sequences. Improved temperature control and occupant comfort; elimination of valve hunting and reduced energy consumption were benefits realized by implementing these measures.

Ali, Mir Muddassir

2011-12-01T23:59:59.000Z

237

DOE NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference NSTB Researchers Demonstrate R&D Successes to Asset Owners at EnergySec Conference October 1, 2009 More than 150 energy sector leaders-including nearly 100 asset owners and operators-gathered at the 2009 EnergySec Annual Summit in Seattle, WA, on Sept. 23-24, where researchers from the Department of Energy's National SCADA Test Bed (NSTB) Program gave a four-hour demonstration and presentation of their Roadmap-related control systems security work. EnergySec is an information sharing forum with more than 230 utility members representing 75 energy companies across the nation. Its fifth annual conference drew asset owners, vendors, and government representatives for presentations and discussions on NERC CIP standards, collaborative industry efforts

238

"Table HC3.2 Living Space Characteristics by Owner-Occupied Housing Units, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

2 Living Space Characteristics by Owner-Occupied Housing Units, 2005" 2 Living Space Characteristics by Owner-Occupied Housing Units, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ," Housing Units (millions) " ,,,"Single-Family Units",,"Apartments in Buildings With--" "Living Space Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Floorspace (Square Feet)" "Total Floorspace1" "Fewer than 500",3.2,1.1,"Q","Q","Q","Q",0.4 "500 to 999",23.8,7.2,3.5,0.3,0.3,0.9,2.2

239

"Table HC3.13 Lighting Usage Indicators by Owner-Occupied Housing Unit Zone, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

3 Lighting Usage Indicators by Owner-Occupied Housing Unit Zone, 2005" 3 Lighting Usage Indicators by Owner-Occupied Housing Unit Zone, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ,"U.S. Housing Units (millions" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Lighting Usage Indicators",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total U.S. Housing Units",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Indoor Lights Turned On During Summer" "Number of Lights Turned On" "Between 1 and 4 Hours per Day",91.8,65,54.3,3.3,1.5,1.6,4.4 "1.",28.6,17.9,14,0.9,0.6,0.7,1.7

240

"Table HC3.4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005" 4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ," Housing Units (millions)" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Space Heating Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Do Not Have Space Heating Equipment",1.2,0.6,0.3,"N","Q","Q","Q" "Have Main Space Heating Equipment",109.8,77.5,63.7,4.2,1.8,2.2,5.6

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

"Table HC3.8 Water Heating Characteristics by Owner-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

8 Water Heating Characteristics by Owner-Occupied Housing Unit, 2005" 8 Water Heating Characteristics by Owner-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ,"U.S. Housing Units (millions" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Water Heating Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Number of Water Heaters" "1.",106.3,74.5,60.9,4,1.8,2.2,5.5 "2 or More",3.7,3.3,3,"Q","Q","Q","Q" "Do Not Use Hot Water",1.1,0.3,"Q","Q","N","Q","Q"

242

"Table HC3.5 Space Heating Usage Indicators by Owner-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

5 Space Heating Usage Indicators by Owner-Occupied Housing Unit, 2005" 5 Space Heating Usage Indicators by Owner-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ," Housing Units (millions)" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Space Heating Usage Indicators",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total U.S. Housing Units",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Do Not Have Heating Equipment",1.2,0.6,0.3,"N","Q","Q","Q" "Have Space Heating Equipment",109.8,77.5,63.7,4.2,1.8,2.2,5.6

243

"Table HC3.7 Air-Conditioning Usage Indicators by Owner-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

7 Air-Conditioning Usage Indicators by Owner-Occupied Housing Unit, 2005" 7 Air-Conditioning Usage Indicators by Owner-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ,"U.S. Housing Units (millions)" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Air Conditioning Usage Indicators",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Do Not Have Cooling Equipment",17.8,11.3,9.3,0.6,"Q",0.4,0.9 "Have Cooling Equipment",93.3,66.8,54.7,3.6,1.7,1.9,4.8 "Use Cooling Equipment",91.4,65.8,54,3.6,1.7,1.9,4.7

244

"Table HC3.11 Home Electronics Characteristics by Owner-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

1 Home Electronics Characteristics by Owner-Occupied Housing Unit, 2005" 1 Home Electronics Characteristics by Owner-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ,"U.S. Housing Units (millions)" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Home Electronics Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Personal Computers" "Do Not Use a Personal Computer ",35.5,20.3,14.8,1.2,0.6,0.9,2.8 "Use a Personal Computer",75.6,57.8,49.2,2.9,1.2,1.4,3 "Number of Desktop PCs"

245

"Table HC3.9 Home Appliances Characteristics by Owner-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

HC3.9 Home Appliances Characteristics by Owner-Occupied Housing Unit, 2005" HC3.9 Home Appliances Characteristics by Owner-Occupied Housing Unit, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ,"U.S. Housing Units (millions" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Home Appliances Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total U.S.",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Cooking Appliances" "Conventional Ovens" "Use an Oven",109.6,77.3,63.4,4.1,1.8,2.3,5.6 "1.",103.3,71.9,58.6,3.9,1.6,2.2,5.5 "2 or More",6.2,5.4,4.8,"Q","Q","Q","Q"

246

"Table HC3.6 Air Conditioning Characteristics by Owner-Occupied Housing Units, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

6 Air Conditioning Characteristics by Owner-Occupied Housing Units, 2005" 6 Air Conditioning Characteristics by Owner-Occupied Housing Units, 2005" " Million U.S. Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ,"U.S. Housing Units (millions" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Air Conditioning Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Do Not Have Cooling Equipment",17.8,11.3,9.3,0.6,"Q",0.4,0.9 "Have Cooling Equipment",93.3,66.8,54.7,3.6,1.7,1.9,4.8 "Use Cooling Equipment",91.4,65.8,54,3.6,1.7,1.9,4.7

247

"Table HC3.1 Housing Unit Characteristics by Owner-Occupied Housing Unit, 2005"  

U.S. Energy Information Administration (EIA) Indexed Site

Housing Unit Characteristics by Owner-Occupied Housing Unit, 2005" Housing Unit Characteristics by Owner-Occupied Housing Unit, 2005" " Million Housing Units" ,," Owner-Occupied Housing Units (millions)","Type of Owner-Occupied Housing Unit" ,"U.S. Housing Units (millions" ,,,"Single-Family Units",,"Apartments in Buildings With--" "Housing Unit Characteristics",,,"Detached","Attached","2 to 4 Units","5 or More Units","Mobile Homes" "Total",111.1,78.1,64.1,4.2,1.8,2.3,5.7 "Census Region and Division" "Northeast",20.6,13.4,10.4,1.4,1,0.3,0.4 "New England",5.5,3.8,3.1,"Q",0.3,"Q","Q" "Middle Atlantic",15.1,9.6,7.3,1.3,0.6,"Q","Q"

248

Steam Boiler Control Specification Problem:  

E-Print Network (OSTI)

Our solution to the specification problem in the specification language TLA+ is based on a model of operation where several components proceed synchronously. Our first specification concerns a simplified controller and abstracts from many details given in the informal problem description. We successively add modules to build a model of the state of the steam boiler, detect failures, and model message transmission. We give a more detailed controller specification and prove that it refines the abstract controller. We also address the relationship between the physical state of the steam boiler and the model maintained by the controller and discuss the reliability of failure detection. Finally, we discuss the implementability of our specification.

Tla Solution Frank; Frank Le Ke; Stephan Merz

1996-01-01T23:59:59.000Z

249

Steam Generator Management Program: Dynamic Analysis of a Steam Generator: Part 2 – Stability Analysis of Representative Steam Gener ators  

Science Conference Proceedings (OSTI)

This report summarizes the results of a project that examined the effect of tube support plate blockage in recirculating steam generators on water level stability. This report builds upon Electric Power Research Institute (EPRI) report 1025134.BackgroundWater level oscillations in recirculating steam generators occur due to hydrodynamic instabilities in the natural circulation system. Utilities have reported water level oscillations in operating steam ...

2013-12-18T23:59:59.000Z

250

Community Resilience: Workshops on Private Sector and Property Owner Requirements for Recovery and Restoration from a Diasaster  

SciTech Connect

This report summarizes the results of a proejct sponsored by DTRA to 1) Assess the readiness of private-sector businesses, building owners, and service providers to restore property and recover operations in the aftermath of a wide-area dispersal of anthrax; and 2) Understand what private property owners and businesses "want and need" from federal, state, and local government to support recovery and restoration from such an incident.

Judd, Kathleen S.; Stein, Steven L.; Lesperance, Ann M.

2008-12-22T23:59:59.000Z

251

Benchmark the Fuel Cost of Steam Generation  

SciTech Connect

This revised ITP tip sheet on benchmarking the fuel cost of steam provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

2006-01-01T23:59:59.000Z

252

Steam-system upgrades | Open Energy Information  

Open Energy Info (EERE)

Linked Data Page Edit History Share this page on Facebook icon Twitter icon Steam-system upgrades Jump to: navigation, search TODO: Add description List of Steam-system...

253

Insulate Steam Distribution and Condensate Return Lines  

Science Conference Proceedings (OSTI)

This revised ITP tip sheet on insulating steam distribution and condensate return lines provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-01-01T23:59:59.000Z

254

What is needed for the steam revolution  

E-Print Network (OSTI)

In four sequences, standing beside a huge steam wheel, Simon Schaffer discusses some of the things that are needed for the development of the steam revolution. These include reliable cylinders (from gun manufacture), good boilers ( from brewing...

Dugan, David

2004-08-18T23:59:59.000Z

255

The steam engine and what it needs  

E-Print Network (OSTI)

Simon Schaffer explains that to produce an effective steam engine you do not just need specific inventions, such as the separate condenser of James Watt, but also skills from clockworking, distillation, metal working and so on. Then the steam power...

Dugan, David

2004-08-18T23:59:59.000Z

256

FEMP-FTA--Steam Trap Performance Assessment  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Steam Trap Function Steam Trap Function Steam traps are automatic valves used in every steam system to remove conden- sate, air, and other non-condensable gases while preventing or minimizing the passing of steam. If condensate is allowed to collect, it reduces the flow capacity of steam lines and the thermal capacity of heat transfer equipment. In addition, excess condensate can lead to "water hammer," with potentially destructive and dangerous results. Air that remains after system startup reduces steam pressure and temperature and may also reduce the thermal capacity of heat transfer equipment. Non-condensable gases, such as oxygen and carbon dioxide, cause corrosion. Steam that passes through the trap provides no heating ser- vice. This effectively reduces the heating capacity

257

Warm or Steaming Ground | Open Energy Information  

Open Energy Info (EERE)

Warm or Steaming Ground Warm or Steaming Ground Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Print PDF Warm or Steaming Ground Dictionary.png Warm or Steaming Ground: An area where geothermal heat is conducted to the earth's surface, warming the ground and sometimes causing steam to form when water is present. Other definitions:Wikipedia Reegle Modern Geothermal Features Typical list of modern geothermal features Hot Springs Fumaroles Warm or Steaming Ground Mudpots, Mud Pools, or Mud Volcanoes Geysers Blind Geothermal System Steam rising from the ground at Eldvorp, a 10 km row of craters, in Southwestern Iceland. http://www.visiticeland.com/SearchResults/Attraction/eldvorp Warm or steaming ground is often an indicator of a geothermal system beneath the surface. In some cases a geothermal system may not show any

258

Calibration of Instrumented Steam Separators to Determine Quality and Flow Distribution in an Operating Steam Generator  

Science Conference Proceedings (OSTI)

This study examined the feasibility of instrumenting steam separators on a steam generator as two-phase flowmeters to measure flow distributions and steam quality near the separator deck plate. Instrumented prototypical separators were tested in a laboratory under steam generator conditions, and test data correlations were developed. The usefulness of such data in the qualification of thermal-hydraulic computer codes was addressed.

1983-01-01T23:59:59.000Z

259

Identifying Steam Opportunity "Impact" Inputs for the Steam System Assessment Tool (SSAT)  

E-Print Network (OSTI)

The U.S. DOE BestPractices Steam "Steam System Assessment Tool" (SSAT) is a powerful tool for quantifying potential steam improvement opportunities in steam systems. However, all assessment tools are only as good as the validity of the modeling inputs.

Harrell, G.; Jendrucko, R.; Wright, A.

2004-01-01T23:59:59.000Z

260

Vapor generator steam drum spray head  

DOE Patents (OSTI)

A typical embodiment of the invention provides a combination feedwater and "cooldown" water spray head that is centrally disposed in the lower portion of a nuclear power plant steam drum. This structure not only discharges the feedwater in the hottest part of the steam drum, but also increases the time required for the feedwater to reach the steam drum shell, thereby further increasing the feedwater temperature before it contacts the shell surface, thus reducing thermal shock to the steam drum structure.

Fasnacht, Jr., Floyd A. (Massillon, OH)

1978-07-18T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Steam Generator Vibration and Wear Protection  

Science Conference Proceedings (OSTI)

This project developed and validated a steam generator flow-induced tube vibration and wear prediction methodology.

1998-03-27T23:59:59.000Z

262

Accelerated Weathering of Fluidized Bed Steam Reformation ...  

Science Conference Proceedings (OSTI)

Sep 16, 2007 ... Accelerated Weathering of Fluidized Bed Steam Reformation Material Under Hydraulically Unsaturated Conditions by E.M. Pierce ...

263

Temperature profiles determine HRSG steam production  

Science Conference Proceedings (OSTI)

This article examine how temperature profiles affect steam production in heat recovery steam generators(HRSG). A typical gas/steam temperature profile for a HRSG is shown. Heat balance equations for the superheater, evaporator, and the complete HRSG are given along with examples for calculating the HRSG temperature profiles after assuming the pinch and approach point temperatures.

Ganapathy, V.

1993-05-01T23:59:59.000Z

264

Capturing Energy Savings with Steam Traps  

E-Print Network (OSTI)

This paper will discuss the energy savings potential of steam traps and present the energy, economic, and environmental reason why an active steam trap maintenance program is good for the company's bottom line. Several case studies will be discussed to demonstrate the merits of steam trap technology.

Bockwinkel, R. G.; French, S. A.

1997-04-01T23:59:59.000Z

265

A LABORATORY INVESTIGATION OF STEAM ADSORPTION  

E-Print Network (OSTI)

A LABORATORY INVESTIGATION OF STEAM ADSORPTION IN GEOTHERMAL RESERVOIR ROCKS OF STANFORD UNIVERSITY, if any, liquid. Yet to satisfy material bal- ance constraints, another phase besides steam must be present. If steam adsorption occurring in significant amounts is not accounted for, the reserves

Stanford University

266

STEAM-WATER RELATIVE PERMEABILITY A DISSERTATION  

E-Print Network (OSTI)

STEAM-WATER RELATIVE PERMEABILITY A DISSERTATION SUBMITTED TO THE DEPARTMENT OF PETROLEUM Laboratory. iv #12;ABSTRACT Steam-water relative permeability curves are required for mathematical models of two-phase geothermal reservoirs. In this study, drainage steam- water relative permeabilities were

Stanford University

267

Steam electric plant factors, 1978. [48 states  

SciTech Connect

Fossil-fuel steam electric generation increased 5.8% in 1977 to 1,612.2 million MWh as compared to 1976. Thirty-four new fossil-fuel steam electric units and 7 new nuclear units became operational in 1977. Detailed data are reported for 748 plants, accounting for more than 99% of the total steam generation capacity, in the contiguous US.

1978-01-01T23:59:59.000Z

268

Materials Performance in USC Steam  

SciTech Connect

The proposed steam inlet temperature in the Advanced Ultra Supercritical (A-USC) steam turbine is high enough (760 °C) that traditional turbine casing and valve body materials such as ferritic/martensitic steels will not suffice due to temperature limitations of this class of materials. Cast versions of several traditionally wrought Ni-based superalloys were evaluated for use as casing or valve components for the next generation of industrial steam turbines. The full size castings are substantial: 2-5,000 kg each half and on the order of 100 cm thick. Experimental castings were quite a bit smaller, but section size was retained and cooling rate controlled to produce equivalent microstructures. A multi-step homogenization heat treatment was developed to better deploy the alloy constituents. The most successful of these cast alloys in terms of creep strength (Haynes 263, Haynes 282, and Nimonic 105) were subsequently evaluated by characterizing their microstructure as well as their steam oxidation resistance (at 760 and 800 °C).

G. R. Holcomb, P. Wang, P. D. Jablonski, and J. A. Hawk

2010-05-01T23:59:59.000Z

269

Solar PV Project Financing: Regulatory and Legislative Challenges for Third-Party PPA System Owners  

DOE Green Energy (OSTI)

Residential and commercial end users of electricity who want to generate electricity using on-site solar photovoltaic (PV) systems face challenging initial and O&M costs. The third-party ownership power purchase agreement (PPA) finance model addresses these and other challenges. It allows developers to build and own PV systems on customers? properties and sell power back to customers. However, third-party electricity sales commonly face five regulatory challenges. The first three challenges involve legislative or regulatory definitions of electric utilities, power generation equipment, and providers of electric services. These definitions may compel third-party owners of solar PV systems to comply with regulations that may be cost prohibitive. Third-party owners face an additional challenge if they may not net meter, a practice that provides significant financial incentive to owning solar PV systems. Finally, municipalities and cooperatives worry about the regulatory implications of allowing an entity to sell electricity within their service territories. This paper summarizes these challenges, when they occur, and how they have been addressed in five states. This paper also presents alternative to the third-party ownership PPA finance model, including solar leases, contractual intermediaries, standardized contract language, federal investment tax credits, clean renewable energy bonds, and waived monopoly powers.

Kollins, K.; Speer, B.; Cory, K.

2009-11-01T23:59:59.000Z

270

Table HC3.4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005  

U.S. Energy Information Administration (EIA) Indexed Site

.4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005 .4 Space Heating Characteristics by Owner-Occupied Housing Unit, 2005 Million U.S. Housing Units Total................................................................ 111.1 78.1 64.1 4.2 1.8 2.3 5.7 Do Not Have Space Heating Equipment....... 1.2 0.6 0.3 N Q Q Q Have Main Space Heating Equipment.......... 109.8 77.5 63.7 4.2 1.8 2.2 5.6 Use Main Space Heating Equipment............ 109.1 77.2 63.6 4.2 1.8 2.1 5.6 Have Equipment But Do Not Use It.............. 0.8 0.3 Q N Q Q Q Main Heating Fuel and Equipment Natural Gas.................................................. 58.2 41.8 35.3 2.8 1.2 1.0 1.6 Central Warm-Air Furnace........................ 44.7 34.8 29.7 2.3 0.7 0.6 1.4 For One Housing Unit........................... 42.9 34.3 29.5 2.3 0.6 0.6 1.4 For Two Housing Units..........................

271

Freeze drying method  

DOE Patents (OSTI)

The present invention provides methods and apparatus for freeze drying in which a solution, which can be a radioactive salt dissolved within an acid, is frozen into a solid on vertical plates provided within a freeze drying chamber. The solid is sublimated into vapor and condensed in a cold condenser positioned above the freeze drying chamber and connected thereto by a conduit. The vertical positioning of the cold condenser relative to the freeze dryer helps to help prevent substances such as radioactive materials separated from the solution from contaminating the cold condenser. Additionally, the system can be charged with an inert gas to produce a down rush of gas into the freeze drying chamber to also help prevent such substances from contaminating the cold condenser.

Coppa, Nicholas V. (Malvern, PA); Stewart, Paul (Youngstown, NY); Renzi, Ernesto (Youngstown, NY)

1999-01-01T23:59:59.000Z

272

Freeze drying apparatus  

Science Conference Proceedings (OSTI)

The present invention provides methods and apparatus for freeze drying in which a solution, which can be a radioactive salt dissolved within an acid, is frozen into a solid on vertical plates provided within a freeze drying chamber. The solid is sublimated into vapor and condensed in a cold condenser positioned above the freeze drying chamber and connected thereto by a conduit. The vertical positioning of the cold condenser relative to the freeze dryer helps to help prevent substances such as radioactive materials separated from the solution from contaminating the cold condenser. Additionally, the system can be charged with an inert gas to produce a down rush of gas into the freeze drying chamber to also help prevent such substances from contaminating the cold condenser.

Coppa, Nicholas V. (Malvern, PA); Stewart, Paul (Youngstown, NY); Renzi, Ernesto (Youngstown, NY)

2001-01-01T23:59:59.000Z

273

Steam cooling system for a gas turbine  

SciTech Connect

The steam cooling circuit for a gas turbine includes a bore tube assembly supplying steam to circumferentially spaced radial tubes coupled to supply elbows for transitioning the radial steam flow in an axial direction along steam supply tubes adjacent the rim of the rotor. The supply tubes supply steam to circumferentially spaced manifold segments located on the aft side of the 1-2 spacer for supplying steam to the buckets of the first and second stages. Spent return steam from these buckets flows to a plurality of circumferentially spaced return manifold segments disposed on the forward face of the 1-2 spacer. Crossover tubes couple the steam supply from the steam supply manifold segments through the 1-2 spacer to the buckets of the first stage. Crossover tubes through the 1-2 spacer also return steam from the buckets of the second stage to the return manifold segments. Axially extending return tubes convey spent cooling steam from the return manifold segments to radial tubes via return elbows.

Wilson, Ian David (Mauldin, SC); Barb, Kevin Joseph (Halfmoon, NY); Li, Ming Cheng (Cincinnati, OH); Hyde, Susan Marie (Schenectady, NY); Mashey, Thomas Charles (Coxsackie, NY); Wesorick, Ronald Richard (Albany, NY); Glynn, Christopher Charles (Hamilton, OH); Hemsworth, Martin C. (Cincinnati, OH)

2002-01-01T23:59:59.000Z

274

Air-cooled vacuum steam condenser  

SciTech Connect

This patent describes a steam powered system. It comprises: a turbine for converting steam energy into mechanical energy upon expansion of steam therein, a boiler for generating steam to be fed to the turbine, and a conduit arrangement coupling the boiler to the turbine and then recoupling the turbine exhaust to the boiler through steam condensing mechanisms. The condensing mechanisms including: a plurality of finned tubes through which the expanded exhaust steam flows and is condensed; a plurality of bundle from headers at the lower ends of the condensing tubes for receiving exhaust steam from the turbine; a plurality of bundle divided rear headers, one for each tube row in the bundle, at the higher ends of the condensing tubes for receiving non-condensible gases; and means in the rear and last headers to remove non-condensible gasses from the rear headers along their full length.

Larinoff, M.W.

1990-03-06T23:59:59.000Z

275

Hydrogen production by high-temperature steam gasification of biomass and coal  

Science Conference Proceedings (OSTI)

High-temperature steam gasification of paper, yellow pine woodchips, and Pittsburgh bituminous coal was investigated in a batch-type flow reactor at temperatures in the range of 700 to 1,200{sup o}C at two different ratios of steam to feedstock molar ratios. Hydrogen yield of 54.7% for paper, 60.2% for woodchips, and 57.8% for coal was achieved on a dry basis, with a steam flow rate of 6.3 g/min at steam temperature of 1,200{sup o}C. Yield of both the hydrogen and carbon monoxide increased while carbon dioxide and methane decreased with the increase in gasification temperature. A 10-fold reduction in tar residue was obtained at high-temperature steam gasification, compared to low temperatures. Steam and gasification temperature affects the composition of the syngas produced. Higher steam-to-feedstock molar ratio had negligible effect on the amount of hydrogen produced in the syngas in the fixed-batch type of reactor. Gasification temperature can be used to control the amounts of hydrogen or methane produced from the gasification process. This also provides mean to control the ratio of hydrogen to CO in the syngas, which can then be processed to produce liquid hydrocarbon fuel since the liquid fuel production requires an optimum ratio between hydrogen and CO. The syngas produced can be further processed to produce pure hydrogen. Biomass fuels are good source of renewable fuels to produce hydrogen or liquid fuels using controlled steam gasification.

Kriengsak, S.N.; Buczynski, R.; Gmurczyk, J.; Gupta, A.K. [University of Maryland, College Park, MD (United States). Dept. of Mechanical Engineering

2009-04-15T23:59:59.000Z

276

Adaptive temperature control system for the supply of steam to a steam turbine  

SciTech Connect

A combined-cycle steam turbine power generating plant is described including a heat recovery steam generator for outputting steam at an instantaneous temperature and pressure, and a steam turbine having rotor expanding steam therethrough from the steam generator; means providing a signal representative of the temperature of the rotor of the turbine; and means for controlling the generation of steam by the steam generator to control the temperature of steam in accordance with a predetermined temperature gradient, the combination of: function generator means responsive to a signal representative of steam turbine throttle pressure for providing a throttle pressure related steam limit temperature according to a constant enthalpy characteristic; bias means responsive to the rotor temperature representative signal for providing a bias signal in excess of the rotor temperature signal by a predetermined amount; means responsive to the larger of the limit temperature signal and the bias signal for controlling the generation of steam by the steam generator to control the temperature of steam to iteratively raise the temperature of the rotor in accordance with the constant enthalpy characteristic and the bias signal during soaking.

Martens, A.; Myers, G.A.

1986-05-20T23:59:59.000Z

277

High-Efficiency Steam Electrolyzer  

SciTech Connect

We are developing a novel high-efficiency, high-temperature steam electrolyzer. Although water or steam electrolysis is well known to be one of the cleanest ways to produce hydrogen, widespread utilization is hindered by high operational costs because of high electricity consumption. To decrease the electrical power input requirements in electrolysis, our approach uses natural gas as an anode depolarizer. This approach essentially replaces one unit of electricity with one equivalent-energy unit of natural gas at much lower cost. The direct use of natural gas on the electrolyzer enables very high system efficiency with respect to primary energy. Experiments performed on single cells have shown a voltage reduction as much as 1 V when compared to conventional electrolyzers. System efficiency has been estimated to be 50 to 80%, depending on the electrolytic current. A 200-W prototype unit is being developed.

Pham, A Q

2001-06-20T23:59:59.000Z

278

IMPROVEMENTS IN OR RELATING TO STEAM GENERATING PLANT  

SciTech Connect

A nuclear power plant is designed using a heavy-watermoderated, steam- cooled reactor. In this plant, feed water is heated by the moderator and reactor steam to form feed steam, which is then superheated by superheated reactor steam and expanded through a nozzle. The feed steam issuing from the nozzie has added to it the superheated reactor steam, and the resulting steam is compressed, heated further in the reactor, and part of it passed to the turbine. (D.L.C.)

Bauer, S.G.; Jubb, D.H.

1962-10-10T23:59:59.000Z

279

Combined gas turbine and steam turbine power plant  

SciTech Connect

A description is given of a power plant arrangement having a gas turbine, a heat recovery steam generator, a steam turbine and means for controlling steam flow from the heat recovery steam generator to the steam turbine. Steam conditions are maintained generally constant and variations in power plant loading are carried by the steam turbine while operating the gas turbine at a generally constant fuel flow.

Baker, J.M.; Clark, G.W.; Harper, D.M.; Tomlinson, L.O.

1978-04-04T23:59:59.000Z

280

Monitoring and Controlling Carryover in Heat Recovery Steam Generators  

Science Conference Proceedings (OSTI)

Optimization of the cycle chemistry in the steam generating system of combined-cycle/heat recovery steam generator (HRSG) plants is vital to ensuring the efficient and reliable operation of the equipment. Monitoring of steam purity and drum carryover are core parameters for HRSG chemistry programs. Carryover is any solid, liquid, or vaporous contaminant that leaves the HRSG steam drum along with the steam. Carryover might be the result of the limited separation of the steam/water mixture in the steam dru...

2010-10-27T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Lessons Learned From Implementation of Westinghouse Owners Group Risk-Informed Inservice Inspection Methodology for Piping  

SciTech Connect

Risk-informed inservice inspection (ISI) programs have been in use for over seven years as an alternative to current regulatory requirements in the development and implementation of ISI programs for nuclear plant piping systems. Programs using the Westinghouse Owners Group (WOG) (now known as the Pressurized Water Reactor Owners Group - PWROG) risk-informed ISI methodology have been developed and implemented within the U.S. and several other countries. Additionally, many plants have conducted or are in the process of conducting updates to their risk-informed ISI programs. In the development and implementation of these risk-informed ISI programs and the associated updates to those programs, the following important lessons learned have been identified and are addressed. Concepts such as 'loss of inventory', which are typically not modeled in a plant's probabilistic risk assessment (PRA) model for all systems. The importance of considering operator actions in the identification of consequences associated with a piping failure and the categorization of segments as high safety significant (HSS) or low safety significant (LSS). The impact that the above considerations have had on the large early release frequency (LERF) and categorization of segments as HSS or LSS. The importance of automation. Making the update process more efficient to reduce costs associated with maintaining the risk-informed ISI program. The insights gained are associated with many of the steps in the risk-informed ISI process including: development of the consequences associated with piping failures, categorization of segments, structural element selection and program updates. Many of these lessons learned have impacted the results of the risk-informed ISI programs and have impacted the updates to those programs. This paper summarizes the lessons learned and insights gained from the application of the WOG risk-informed ISI methodology in the U.S., Europe and Asia. (authors)

Stevenson, Paul R.; Haessler, Richard L. [Westinghouse Electric Company, LLC (United States); McNeill, Alex [Dominion Energy, Innsbrook Technical Center (United States); Pyne, Mark A. [Duke Energy (United States); West, Raymond A. [Dominion Nuclear Connecticut, Inc. - Dominion Generation (United States)

2006-07-01T23:59:59.000Z

282

Development and Application of Advanced Models for Steam Hydrogasification: Process Design and Economic Evaluation  

E-Print Network (OSTI)

in a Heat Recovery Steam Generator (HRSG) to make additionalAuxiliary Power Block Steam turbine generator using steam

Lu, Xiaoming

2012-01-01T23:59:59.000Z

283

Steam Turbine Materials and Corrosion  

Science Conference Proceedings (OSTI)

Ultra-supercritical (USC) power plants offer the promise of higher efficiencies and lower emissions. Current goals of the U.S. Department of Energy’s Advanced Power Systems Initiatives include coal generation at 60% efficiency, which would require steam temperatures of up to 760 °C. In prior years this project examined the steamside oxidation of alloys for use in high- and intermediate-pressure USC turbines. This steamside oxidation research is continuing and progress is presented, with emphasis on chromia evaporation.

Holcomb, G.H.; Hsu, D.H.

2008-07-01T23:59:59.000Z

284

Steam Turbine Materials and Corrosion  

E-Print Network (OSTI)

Ultra-supercritical (USC) power plants offer the promise of higher efficiencies and lower emissions. Current goals of the U.S. Department of Energy’s Advanced Power Systems Initiatives include coal generation at 60 % efficiency, which would require steam temperatures of up to 760 °C. In prior years this project examined the steamside oxidation of alloys for use in high- and intermediate-pressure USC turbines. This steamside oxidation research is continuing and progress is presented, with emphasis on chromia evaporation.

Gordon R. Holcomb; Derek Hsu

2007-01-01T23:59:59.000Z

285

Steam systems in industry: Energy use and energy efficiency improvement potentials  

E-Print Network (OSTI)

Repair Flash Steam Recovery/ Condensate Return Condensateflash steam. When a steam trap purges condensate from ais removed by a steam trap, which allows condensate to pass

Einstein, Dan; Worrell, Ernst; Khrushch, Marta

2001-01-01T23:59:59.000Z

286

Preliminary results of thermal igniter experiments in H/sub 2/-air-steam environments. [PWR; BWR  

DOE Green Energy (OSTI)

Thermal igniters (glow plugs), proposed by the Tennessee Valley Authority for intentional ignition of hydrogen in nuclear reactor containment, have been tested for functionability in mixtures of air, hydrogen, and steam. Test environments included 6% to 16% hydrogen concentrations in air, and 8%, 10%, and 12% hydrogen in mixtures with 30% and 40% steam fractions. All were conducted in a 10.6 ft/sup 3/ insulated pressure vessel. For all of these tests the glow plug successfully initiated combustion. Dry air/hydrogen tests exhibited a distinct tendency for complete combustion at hydrogen concentrations between 8% and 9%. Steam suppressed both peak pressures and completeness of combustion. No combustion could be initiated at or above a 50% steam fraction. Circulation of the mixture with a fan increased the completeness of combustion. The glow plug showed no evidence of performance degradation throughout the program.

Lowry, W.

1981-01-01T23:59:59.000Z

287

The economics of repowering steam turbines  

SciTech Connect

Repowering is defined as displacing steam presently generated in an existing fossil fuel fired boiler with a gas turbine-heat recovery steam generator (HRSG) system. The steam generated in the HRSG is expanded in the existing steam turbine generator. Repowering advantages include a significant increase in power output at an improved heat rate relative to the base value for the existing steam turbine cycle being repowered. In addition, the reduction in emissions can be advantageous in most locations. This paper discusses application and economic considerations associated with repowering. In addition, an illustration will show how repowering coal fired steam turbine systems may prove economic relative to retrofit scrubbers and/or low sulfur coal fuel substitution that may be part of the forthcoming acid rain legislation.

Kovacik, J.M.; Stoll, H.G. (General Electric Co., Schenectady, NY (United States))

1990-01-01T23:59:59.000Z

288

Steam System Optimization : A Case Study  

E-Print Network (OSTI)

The steam system optimization (generation, distribution, use and condensate return) offers a large opportunity for action to comply with the new levels of energy efficiency standards. Superior design and improved maintenance practices are the two main sources of savings in steam systems. Increased competition no longer permits an industry to survive with energy waste that could be eliminated. This paper highlights the study findings of the steam system in a plant from the Food industry. The steam system operates with an annual budget of $1.9 million. Normal steam demand ranges between 80,000 to 85,000 lb/hr. The steam system analysis identified energy savings worth $270,000 per year. The optimization measures were in two categories: • No cost/low cost optimizations that can be done through a better maintenance and improved operating condition • Major improvements that require a significant investment, and includes the modification of the process and major equipment.

Iordanova, N.; Venkatesan, V. V.; Calogero, M.

2002-04-01T23:59:59.000Z

289

Steam Management- The 3M Approach  

E-Print Network (OSTI)

As one of the world's leading manufacturers of innovative products, 3M is continually working to improve energy efficiency in offices, research centers, and production facilities. Steam system optimization is one of the keys to this process, beginning at the boiler room and continuing throughout the facility. Boiler selection, installation, and operation are carefully monitored to ensure that steam is produced as efficiently as possible. The program encourages 3M facilities to establish Steam Teams to monitor and maintain steam systems. These teams are in continual contact with corporate facilities specialists in order to readily resolve problems relating to distribution, piping, and trapping. Team goals include evaluating existing equipment installations to verify that their design is appropriate for today's needs, periodically evaluating steam traps for correct selection and correct operation, and regularly inspecting steam and condensate piping runs to ensure that they are functioning safely and correctly.

Renz, R. L.

2000-04-01T23:59:59.000Z

290

Energy Savings Through Steam Trap Management  

E-Print Network (OSTI)

Sustainability and energy management are broad topics which have become a common focus in industry. Recognizing the need for greater cost reduction and competitive advantage through sustainability, industry is putting forth resources to improve energy management controls. When the topic of energy management relates to steam trap management however, the focus becomes less clear and action less notable. The seemingly “low hanging” fruit of steam traps are not often tied to significant and sustainable energy management projects. Typically this holds true because of the failure of industry to put a value on the cost of steam and because of the lack of energy tracking from failed steam traps as part of best practice. The use of technology can help industry transform how steam systems are managed and sustainability in steam systems is achieved.

Gibbs, C.

2008-01-01T23:59:59.000Z

291

Use Steam Jet Ejectors or Thermocompressors to Reduce Venting of Low-Pressure Steam  

SciTech Connect

This revised ITP tip sheet on steam jet ejectors and thermocompressors provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

2006-01-01T23:59:59.000Z

292

Steam Challenge: Developing A New DOE Program to Help Industry be Steam Smart  

E-Print Network (OSTI)

Last year, the Alliance to Save Energy, the Department of Energy's Office of Industrial Technologies, and a cadre of private companies and associations formed an innovative "Steam Partnership" with the goal of developing a new, DOE technical assistance program on steam efficiency. In 1997, the Steam Partnership began to define the appropriate activities, tools, and services of a public-private program on steam. Modeled after the successful Motor Challenge program and the newly launched Compressed Air Challenge program, "Steam Challenge" will highlight the importance of steam system efficiency and provide information and technical assistance on technologies for today's industrial steam systems. This paper will introduce Steam Challenge, describe what has been accomplished over the last year, and describe the program's future goals and activities.

Jones, T.; Hart, F.

1998-04-01T23:59:59.000Z

293

Advances in steam turbine technology for power generation  

SciTech Connect

This book contains articles presented at the 1990 International Joint Power Generation Conference. It is organized under the following headings: Solid particle erosion in steam turbines, Steam turbine failure analysis, Steam turbine upgrades, steam turbine blading development, Boiler feed pumps and auxiliary steam turbine drives.

Bellanca, C.P. (Dayton Power and Light Company (US))

1990-01-01T23:59:59.000Z

294

Method of steam reforming methanol to hydrogen  

DOE Patents (OSTI)

The production of hydrogen by the catalyzed steam reforming of methanol is accomplished using a reformer of greatly reduced size and cost wherein a mixture of water and methanol is superheated to the gaseous state at temperatures of about 800.degree. to about 1,100.degree. F. and then fed to a reformer in direct contact with the catalyst bed contained therein, whereby the heat for the endothermic steam reforming reaction is derived directly from the superheated steam/methanol mixture.

Beshty, Bahjat S. (Lower Makefield, PA)

1990-01-01T23:59:59.000Z

295

Final Environmental Assessment for the Y-12 Steam Plant Life Extenstion Project - Steam Plant Replacement Subproject  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

93 93 Final Environmental Assessment for the Y-12 Steam Plant Life Extension Project - Steam Plant Replacement Subproject U.S. Department of Energy National Nuclear Security Administration August 2007 Final Y-12 Steam Plant Life Extension Project - Steam Plant Replacement Subproject - August 2007 i TABLE OF CONTENTS List of Acronyms and Abbreviations............................................................................................. vi Chemicals and Units of Measure ................................................................................................. ix Conversion Chart ......................................................................................................................... xi Metric Prefixes .............................................................................................................................xii

296

Industrial Heat Pumps for Steam and Fuel Savings: A BestPractices Steam Technical Brief  

SciTech Connect

The purpose of this Steam Techcial Brief is to introduce heat-pump technology and its applicaiton in industrial processes.

2003-06-01T23:59:59.000Z

297

Steam Generator Management Program: Steam Generator Engineering Training Course 2 Handbook  

Science Conference Proceedings (OSTI)

This Technical Update provides training material that was prepared for the second Steam Generator Engineering Training class. The Steam Generator Engineering Training is a comprehensive training program for steam generator program managers. The content of the training is based on an industry-developed job analysis for a steam generator engineer. The job analysis resulted in eight high-level tasks; consequently, eight training modules were planned to be developed over a three-year period beginning in 2008...

2010-04-26T23:59:59.000Z

298

Dry piston coal feeder  

SciTech Connect

This invention provides a solids feeder for feeding dry coal to a pressurized gasifier at elevated temperatures substantially without losing gas from the gasifier by providing a lock having a double-acting piston that feeds the coals into the gasifier, traps the gas from escaping, and expels the trapped gas back into the gasifier.

Hathaway, Thomas J. (Belle Meade, NJ); Bell, Jr., Harold S. (Madison, NJ)

1979-01-01T23:59:59.000Z

299

Save Energy Now in Your Steam Systems  

SciTech Connect

This DOE Industrial Technologies Program fact sheet describes how manufacturing plants can save energy and money by making energy efficiency improvements to their industrial steam systems.

2006-01-01T23:59:59.000Z

300

Major Corrosion Problems in Steam Turbines  

Science Conference Proceedings (OSTI)

...O. Jonas, Corrosion of Steam Turbines, Corrosion: Environments and Industries, Vol 13C, ASM Handbook, ASM International, 2006, p 469â??476...

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Efficiently generate steam from cogeneration plants  

SciTech Connect

As cogeneration gets more popular, some plants have two choices of equipment for generating steam. Plant engineers need to have a decision chart to split the duty efficiently between (oil-fired or gas-fired) steam generators (SGs) and heat recovery steam generators (HRSGs) using the exhaust from gas turbines. Underlying the dilemma is that the load-versus-efficiency characteristics of both types of equipment are different. When the limitations of each type of equipment and its capability are considered, analysis can come up with several selection possibilities. It is almost always more efficient to generate steam in an HRSG (designed for firing) as compared with conventional steam generators. However, other aspects, such as maintenance, availability of personnel, equipment limitations and operating costs, should also be considered before making a final decision. Loading each type of equipment differently also affects the overall efficiency or the fuel consumption. This article describes the performance aspects of representative steam generators and gas turbine HRSGs and suggests how plant engineers can generate steam efficiently. It also illustrates how to construct a decision chart for a typical installation. The equipment was picked arbitrarily to show the method. The natural gas fired steam generator has a maximum capacity of 100,000 lb/h, 400-psig saturated steam, and the gas-turbine-exhaust HRSG has the same capacity. It is designed for supplementary firing with natural gas.

Ganapathy, V. [ABCO Industries, Abilene, TX (United States)

1997-05-01T23:59:59.000Z

302

Steam System Improvement: A Case Study  

E-Print Network (OSTI)

The industrial sector consumes the largest share of the world's energy. The pulp and paper industry is one of the five most energy-intensive industries in the world. Therefore, optimum energy efficiency plays a pivotal role in the profitability of this sector. Also, energy cost accounts for a significant share in production cost in pulp and paper industries. This paper highlights the findings of a study done on the steam system of a paper mill (covering steam generation, steam distribution and steam usage) where steam generation accounts for 85% of the total energy used. Therefore, optimization of the steam system has the biggest energy saving potential. This paper mill produces 40,000 pounds of steam at 600 psig and distributes it to the paper-making process at various pressure levels. This New England paper mill spends approximately $1.9 million every year on its steam system. The study identified an opportunity to save the plant steam costs in the amount of 12%. Among the identified saving measures, there are some measures that can be done through better maintenance and improvement of operating conditions. The average payback period to implement the identified saving measures is 12 months. In addition to this, upon the implementation of the proposed measures, the paper mill can reduce its carbon emissions in the amount of 500 tons per year and thus, can help save the environment as well.

Leigh, N.; Venkatesan, V. V.

1999-05-01T23:59:59.000Z

303

Coreflood experimental study of steam displacement.  

E-Print Network (OSTI)

??The main objective of this study was to verify experimentally whether or not a Buckley-Leverett shock front exists when steam displaces oil in a porous… (more)

Cerutti, Andres Enrique

2012-01-01T23:59:59.000Z

304

The Bending of Wood With Steam.  

E-Print Network (OSTI)

??Based on experimentation with the steam bending of wood to curved shapes, this thesis describes my involvement with three basic aspects of the process. First… (more)

Cottey Jr., James H.

2008-01-01T23:59:59.000Z

305

Steam Reheat in Nuclear Power Plants.  

E-Print Network (OSTI)

??In this work, reheating steam from a commercial nuclear power plant is explored in order to increase efficiency and power output. A thermal source in… (more)

Marotta, Paul John

2012-01-01T23:59:59.000Z

306

Steam catalysis in CaO carbonation under low steam partial pressure  

Science Conference Proceedings (OSTI)

CaO was widely used to capture CO{sub 2} in direct hydrogen production process, where steam always existed simultaneously. The effect of steam on CaO carbonation performance under low steam partial pressure was investigated using a pressurized thermogravimetric apparatus. The experimental results revealed that steam improved CaO carbonation performance significantly no matter whether Ca(OH){sub 2} was produced or not. At 823 K and 0.5 MPa of steam partial pressure, effect of steam on CaO carbonation performance could not be attributed mainly to production of Ca(OH){sub 2} because the hydration rate of CaO was very slow. The main reason was steam catalysis in CaO carbonation. Enhancement of steam on CaO carbonation performance without Ca(OH){sub 2} production could not be attributed to improvement of steam on the physical property, but to catalytic effect of steam. Effects of CaO precursors, CO{sub 2} partial pressure, steam partial pressure, and temperature with steam addition on CaO carbonation performance were also investigated.

Yang, S.J.; Xiao, Y.H. [Chinese Academy of Science, Beijing (China)

2008-06-15T23:59:59.000Z

307

Comparative analysis of alternative means for removing noncondensable gases from flashed-steam geothermal power plants  

DOE Green Energy (OSTI)

This is a final report on a screening study to compare six methods of removing noncondensable gases from direct-use geothermal steam power plants. This report defines the study methodologies and compares the performance and economics of selected gas-removal systems. Recommendations are presented for follow-up investigations and implementation of some of the technologies discussed. The specific gas-removal methods include five vacuum system configurations using the conventional approach of evacuating gas/vapor mixtures from the power plant condenser system and a system for physical separation of steam and gases upstream of the power turbine. The study focused on flashed-steam applications, but the results apply equally well to flashed-steam and dry-steam geothermal power plant configurations. Two gas-removal options appear to offer profitable economic potential. The hybrid vacuum system configurations and the reboiler process yield positive net present value results over wide-ranging gas concentrations. The hybrid options look favorable for both low-temperature and high-temperature resource applications. The reboiler looks profitable for low-temperature resource applications for gas levels above about 20,000 parts per million by volume. A vacuum system configuration using a three-stage turbocompressor battery may be profitable for low-temperature resources, but results show that the hybrid system is more profitable. The biphase eductor alternative cannot be recommended for commercialization at this time.

Vorum, M.; Fitzler, E.

2000-06-20T23:59:59.000Z

308

Energy Input and Quality of Pellets Made from Steam-Exploded Douglas Fir (Pseudotsuga menziesii)  

SciTech Connect

Ground softwood Douglas fir (Pseudotsuga menziesii) was treated with pressurized saturated steam at 200-220 C (1.6-2.4 MPa) for 5-10 min in a sealed container. The contents of the container were released to the atmosphere for a sudden decompression. The steam-exploded wood particles were dried to 10% moisture content and pelletized in a single-piston-cylinder system. The pellets were characterized for their mechanical strength, chemical composition, and moisture sorption. The steamtreated wood required 12-81% more energy to compact into pellets than the untreated wood. Pellets made from steam-treated wood had a breaking strength 1.4-3.3 times the strength of pellets made from untreated wood. Steam-treated pellets had a reduced equilibrium moisture content of 2-4% and a reduced expansion after pelletization. There was a slight increase in the high heating value from 18.94 to 20.09 MJ/kg for the treated samples. Steam-treated pellets exhibited a higher lengthwise rigidity compared to untreated pellets.

Sokhansanj, Shahabaddine [ORNL; Bi, X.T. [University of British Columbia, Vancouver; Lim, C. Jim [University of British Columbia, Vancouver; Melin, Staffan [University of British Columbia, Vancouver

2011-01-01T23:59:59.000Z

309

Steam turbine materials and corrosion  

SciTech Connect

Ultra-supercritical (USC) power plants offer the promise of higher efficiencies and lower emissions. Current goals of the U.S. Department of Energy’s Advanced Power Systems Initiatives include power generation from coal at 60% efficiency, which would require steam temperatures of up to 760°C. This project examines the steamside oxidation of candidate alloys for use in USC systems, with emphasis placed on applications in high- and intermediate-pressure turbines. As part of this research a concern has arisen about the possibility of high chromia evaporation rates of protective scales in the turbine. A model to calculate chromia evaporation rates is presented.

Holcomb, G.R.; Alman, D.E.; Dogan, O.N.; Rawers, J.C.; Schrems, K.K.; Ziomek-Moroz, M.

2007-12-01T23:59:59.000Z

310

Foam Cleaning of Steam Turbines  

E-Print Network (OSTI)

The efficiency and power output of a steam turbine can be dramatically reduced when deposits form on the turbine blades. Disassembly and mechanical cleaning of the turbine is very time consuming and costly. Deposits can be removed from the turbine internals in situ by foaming an appropriate cleaning solution and injecting it through the turbine, dissolving the deposits and removing them from the system. Because disassembly of the turbine is not required, foam cleaning is a much faster and more cost-effective method of removing deposits. In recent years, HydroChem has removed copper deposits from over 130 Westinghouse and General Electric turbines nationwide using patented equipment.

Foster, C.; Curtis, G.; Horvath, J. W.

2000-04-01T23:59:59.000Z

311

Designing an ultrasupercritical steam turbine  

Science Conference Proceedings (OSTI)

Carbon emissions produced by the combustion of coal may be collected and stored in the future, but a better approach is to reduce the carbon produced through efficient combustion technologies. Increasing the efficiency of new plants using ultrasupercritical (USC) technology will net less carbon released per megawatt-hour using the world's abundant coal reserves while producing electricity at the lowest possible cost. The article shows how increasing the steam turbine operating conditions for a new USC project in the USA and quantify the potential CO{sub 2} reduction this advanced design makes possible. 7 figs., 3 tabs.

Klotz, H.; Davis, K.; Pickering, E. [Alstom (Germany)

2009-07-15T23:59:59.000Z

312

Table HC1-5a. Housing Unit Characteristics by Type of Owner-Occupied Housing Unit,  

U.S. Energy Information Administration (EIA) Indexed Site

5a. Housing Unit Characteristics by Type of Owner-Occupied Housing Unit, 5a. Housing Unit Characteristics by Type of Owner-Occupied Housing Unit, Million U.S. Households, 2001 Housing Unit Characteristics RSE Column Factor: Total Owner- Occupied Units Type of Owner-Occupied Housing Unit RSE Row Factors Single-Family Apartments in Buildings With Mobile Homes Two to Four Units Five or More Units 0.4 0.4 1.8 2.1 1.4 Total ............................................... 72.7 63.2 2.1 1.8 5.7 6.7 Census Region and Division Northeast ...................................... 13.0 10.8 1.1 0.5 0.6 11.4 New England .............................. 3.5 3.1 0.2 Q 0.1 16.9 Middle Atlantic ............................ 9.5 7.7 0.9 0.4 0.4 13.4 Midwest ......................................... 17.5 16.0 0.3 Q 1.0 10.3 East North Central ......................

313

47318 Federal Register / Vol. 77, No. 153 / Wednesday, August 8, 2012 / Rules and Regulations bluefin tuna landed by owners of  

E-Print Network (OSTI)

bluefin tuna landed by owners of vessels not permitted to do so under § 635.4, or purchase, receive, or transfer, or attempt to purchase, receive, or transfer Atlantic bluefin tuna without the appropriate valid Federal Atlantic tunas dealer permit issued under § 635.4. Purchase, receive, or transfer or attempt

314

The consumer's guide to earth sheltered housing: A step-by-step workbook for prospective owners  

SciTech Connect

Earth sheltered homes have captured the imagination of many homeowners seeking the cost and energy savings features they offer. This book provides the discussion of the advantages and disadvantages of such homes and includes illustrations showing interiors and exteriors with advise to owners on dealine with architects and contractors.

Rollwagen, M.

1985-01-01T23:59:59.000Z

315

Table HC7-5a. Home Office Equipment by Type of Owner-Occupied Housing Unit,  

U.S. Energy Information Administration (EIA) Indexed Site

5a. Home Office Equipment by Type of Owner-Occupied Housing Unit, 5a. Home Office Equipment by Type of Owner-Occupied Housing Unit, Million U.S. Households, 2001 Home Office Equipment RSE Column Factor: Total Owner- Occupied Units Type of Owner-Occupied Housing Unit RSE Row Factors Single-Family Apartments in Buildings With Mobile Home Two to Four Units Five or More Units 0.3 0.3 2.1 3.0 1.6 Total ............................................... 72.7 63.2 2.1 1.8 5.7 6.7 Households Using Office Equipment .......................... 67.5 59.0 2.0 1.7 4.8 7.0 Personal Computers 1 ................... 45.7 41.1 1.3 0.9 2.4 8.6 Number of Desktop PCs 1 .................................................. 34.1 30.5 1.0 0.7 1.9 9.7 2 or more .................................... 7.4 7.0 Q Q 0.2 18.4 Number of Laptop PCs 1 ..................................................

316

Transient Steam Flow in Porous Media - Theory and Experiment  

SciTech Connect

The adsorption of steam in porous media, leading to a delay in steam pressure breakthrough, has been incorporated into a revised model of steam flow in a porous medium.

Herkelrath, W.N.; Moench, A.F.

1980-12-16T23:59:59.000Z

317

Steam Plant Replaces Outdated Coal-Fired System | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Steam Plant Replaces Outdated Coal-Fired System Steam Plant Replaces Outdated Coal-Fired System September 1, 2012 - 12:00pm Addthis A new natural gas-fired steam plant will replace...

318

Computational Modeling of Combined Steam Pyrolysis and Hydrogasification of Ethanol  

E-Print Network (OSTI)

is fed to the steam methane reformer from which we getis fed into the steam methane reformer where it is convertedis produced in the steam methane reformer. Fischer-Tropsch

Singh, S; Park, C S; Norbeck, J N

2005-01-01T23:59:59.000Z

319

Computational Modeling of Combined Steam Pyrolysis and Hydrogasification of Ethanol  

E-Print Network (OSTI)

H. (1981). Reactivities of carbon to steam and hydrogen andreaction kinetics of steam gasification for a transportof coal gasification with steam and CO2. Fuel, 77(15), 17.

Singh, S; Park, C S; Norbeck, J N

2005-01-01T23:59:59.000Z

320

Safety Evaluation Report related to Hydrogen Control Owners Group assessment of Mark 3 containments  

DOE Green Energy (OSTI)

Title 10 of the Code of Federal Regulations (10 CFR), Section 50.44 Standards for Combustible Gas Control System in Light-Water-Cooled Power Reactors,'' requires that systems be provided to control hydrogen concentration in the containment atmosphere following an accident to ensure that containment integrity is maintained. The purpose of this report is to provide regulatory guidance to licensees with Mark III containments with regard to demonstrating compliance with 10 CFR 50.44, Section (c)(3)(vi) and (c)(3)(vii). In this report, the staff provides its evaluation of the generic methodology proposed by the Hydrogen Control Owners Group. This generic methodology is documented in Topical Report HGN-112-NP, Generic Hydrogen Control Information for BWR/6 Mark III Containments.'' In addition, the staff has recommended that the vulnerability to interruption of power to the hydrogen igniters be evaluated further on a plant-specific basis as part of the individual plant examination of the plants with Mark III containments. 10 figs., 1 tab.

Li, C.Y.; Kudrick, J.A.

1990-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Steam  

E-Print Network (OSTI)

stations ? Retail Access was established in MD in 2000 ? As part of deregulation, many state policymakers required that customers ’ rates be frozen – in most cases below the wholesale cost of power ? As rate freezes expired, rates increased to reflect market ratesThe Electric Utility Industry ? The electric utility industry consists of three functions needed to deliver power to customer loads:

Joan Kowal

2009-01-01T23:59:59.000Z

322

High-Efficiency Steam Electrolyzer  

SciTech Connect

We are developing a novel high-efficiency, high-temperature steam electrolyzer. Although water or steam electrolysis is well known to be one of the cleanest ways to produce hydrogen, widespread utilization is hindered by high operational costs because of high electricity consumption. To decrease the electrical power input requirements in electrolysis, our approach uses natural gas as an anode depolarizer. This approach essentially replaces one unit of electricity with one equivalent-energy unit of natural gas at much lower cost. The direct use of natural gas on the electrolyzer enables very high system efficiency with respect to primary energy. Experiments performed on single cells have shown a voltage reduction as much as 1 V when compared to conventional electrolyzers. System efficiency has been estimated to be 50 to 80%, depending on the electrolytic current density. During FY02, we have accomplished several major milestones, including the development of a metal-to-ceramic seal that withstands 150 psi differential, the fabrication of the electrolyzer tubes of up to 16 inches in length, the improvement of single tube performance and the demonstration of the first electrolyzer stack.

Pham, A Q; See, E; Lenz, D; Martin, P; Glass, R

2002-07-03T23:59:59.000Z

323

Drying radioactive wastewater salts using a thin film dryer  

SciTech Connect

This paper describes the operational experience in drying brines generated at a radioactive wastewater treatment facility. The brines are composed of aqueous ammonium sulfate/sodium sulfate and aqueous sodium nitrate/sodium sulfate, The brine feeds receive pretreatment to preclude dryer bridging and fouling. The dryer products are a distillate and a powder. The dryer is a vertical thin film type consisting of a steam heated cylinder with rotor. Maintenance on the dryer has been minimal. Although many operability problems have had to be overcome, dryer performance can now be said to be highly reliable.

Scully, D.E.

1998-03-19T23:59:59.000Z

324

Session: Hot Dry Rock  

DOE Green Energy (OSTI)

This session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of four presentations: ''Hot Dry Rock - Summary'' by George P. Tennyson, Jr.; ''HDR Opportunities and Challenges Beyond the Long Term Flow Test'' by David V. Duchane; ''Start-Up Operations at the Fenton Hill HDR Pilot Plant'' by Raymond F. Ponden; and ''Update on the Long-Term Flow Testing Program'' by Donald W. Brown.

Tennyson, George P. Jr.; Duchane, David V.; Ponden, Raymond F.; Brown, Donald W.

1992-01-01T23:59:59.000Z

325

Corrosion of Low Pressure Steam Turbine Components  

Science Conference Proceedings (OSTI)

Most outage hours for steam turbines are due to corrosion of low pressure (LP) blades and disks in the phase transition zone (PTZ). The development of an effective localized corrosion damage prediction technology is essential for the successful avoidance of unscheduled outages of steam

2000-11-28T23:59:59.000Z

326

Steam Conservation and Boiler Plant Efficiency Advancements  

E-Print Network (OSTI)

This paper examines several cost-effective steam conservation and boiler plant efficiency advancements that were implemented during a recently completed central steam boiler plant replacement project at a very large semiconductor manufacturing complex. The measures include: 1) Reheating of dehumidified cleanroom make-up air with heat extracted during precooling. 2) Preheating of deionization feedwater with refrigerant heat of condensation. 3) Preheating of boiler combustion air with heat extracted from boiler flue gas. 4) Preheating of boiler feedwater with heat extracted from gas turbine exhaust. 5) Variable speed operation of boiler feedwater pumps and forced-draft fans. 6) Preheating of boiler make-up water with heat extracted from boiler surface blow-down. The first two advancements (steam conservation measures) reduced the amount of steam produced by about 25% and saved about $1,010,000/yr by using recovered waste heat rather than steam-derived heat at selected heating loads. The last four advancements (boiler plant efficiency measures) reduced the unit cost of steam produced by about 13% and saved about $293,500/yr by reducing natural gas and electricity usage at the steam boiler plant. The combined result was a 35% reduction in annual steam costs (fuel and power).

Fiorino, D. P.

2000-04-01T23:59:59.000Z

327

LMR steam generator blowdown with RETRAN  

SciTech Connect

One of the transients being considered in the FSAR Chapter 15 analyses of anticipated LMR transients is the fast blowdown of a steam generator upon inadvertent actuation of the liquid metal/water reaction mitigation system. For the blowdown analysis, a stand-alone steam generator model for the IFR plant was constructed using RETRAN.

Wei, T.Y.C.

1985-01-01T23:59:59.000Z

328

Steam System Optimization: A Case Study  

E-Print Network (OSTI)

This paper highlights the study findings in a steam system in a plant from a multinational Petrochemical giant in an European country. The steam system operates with an annual budget of $8.9 million (local currency was converted to US Dollars). Normal steam demand ranges from 500,000 to 600,000 lbs/hr. 380,000 lbs/hr is imported from an outside power plant and 170,000 lbs/hr is internally generated as waste heat recovery. The steam system analysis identified energy savings worth of $2,400,000 per year. The optimization measures were in two categories: • no cost / low cost that can be done through better maintenance and improvement of operating conditions. • major improvement that requires a significant amount of investment, that includes the modification of process and major equipment. Though the findings are specific to a single site, the basics of steam system analysis are applicable to any steam system. A critical review on any steam system always identifies controllable wastes. Improvements in steam system efficiency equal reduced energy consumption and saved environment.

Iordanova, N.; Venkatesan, V. V.

2000-04-01T23:59:59.000Z

329

The Future of Steam: A Preliminary Discussion  

E-Print Network (OSTI)

Steam production represents a significant proportion of today's industrial energy demand. But the evolution of process technologies, as well as turbulence in energy markets, suggests that steam's role may be subject to change in the next decade. Questions as to the ways those changes will manifest are addressed by this paper. Specifically, the text presents an outline of parameters that (in the authors' opinions) will ultimately shape the dimensions of industrial steam use in the next 10 to 20 years. Technical, business, institutional, and labor developments are the forces in question. This paper provides a systematic review of these forces, and suggests how they may influence industrial asset purchasing decisions. The coming decade will witness opportunities for maintaining and growing steam markets, but there are also reasons to believe that steam will be supplanted by alternative technologies in certain industries and applications. Combined heat and power applications are the wildcard in this formula, since they may facilitate the replacement of some traditional steam applications. But at the same time, CHP may ensure that steam indirectly serves industry by powering generators that serve newer electric applications. The trends discussed in this paper suggest the components for an industrial steam policy agenda.

Russell, C.; Harrell, G.; Moore, J.; French, S.

2001-05-01T23:59:59.000Z

330

Pages that link to "Coyote Canyon Steam Plant Biomass Facility...  

Open Energy Info (EERE)

Share this page on Facebook icon Twitter icon Pages that link to "Coyote Canyon Steam Plant Biomass Facility" Coyote Canyon Steam Plant Biomass Facility Jump to:...

331

Steam Oxidation of New PVD Nano-Structured and Microstructured ...  

Science Conference Proceedings (OSTI)

Symposium, Properties, Processing, and Performance of Steels and Ni-Based Alloys for Advanced Steam Conditions. Presentation Title, Steam Oxidation of ...

332

Changes related to "Coyote Canyon Steam Plant Biomass Facility...  

Open Energy Info (EERE)

Share this page on Facebook icon Twitter icon Changes related to "Coyote Canyon Steam Plant Biomass Facility" Coyote Canyon Steam Plant Biomass Facility Jump to:...

333

Boiler Upgrades and Decentralizing Steam Systems Save Water and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Boiler Upgrades and Decentralizing Steam Systems Save Water and Energy at Naval Air Station Oceana Boiler Upgrades and Decentralizing Steam Systems Save Water and Energy at Naval...

334

Design with Constructal Theory: Steam Generators, Turbines and Heat Exchangers.  

E-Print Network (OSTI)

?? This dissertation shows that the architecture of steam generators, steam turbines and heat exchangers for power plants can be predicted on the basis of… (more)

Kim, Yong Sung

2010-01-01T23:59:59.000Z

335

Savannah River's Biomass Steam Plant Success with Clean and Renewable...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River's Biomass Steam Plant Success with Clean and Renewable Energy Savannah River's Biomass Steam Plant Success with Clean and Renewable Energy In order to meet the...

336

Savannah River's Biomass Steam Plant Success with Clean and Renewable...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

River's Biomass Steam Plant Success with Clean and Renewable Energy Savannah River's Biomass Steam Plant Success with Clean and Renewable Energy In order to meet the federal energy...

337

Hockey-stick steam generator for LMFBR  

SciTech Connect

This paper presents the criteria and evaluation leading to the selection of the Hockey Stick Steam Generator Concept and subsequent development of that concept for LMFBR application. The selection process and development of the Modular Steam Generator (MSG) is discussed, including the extensive test programs that culminated in the manufacture and test of a 35 MW(t) Steam Generator. The design of the CRBRP Steam Generator is described, emphasizing the current status and a review of the critical structural areas. CRBRP steam generator development tests are evaluated, with a discussion of test objectives and rating of the usefulness of test results to the CRBRP prototype design. Manufacturing experience and status of the CRBRP prototype and plant units is covered. The scaleup of the Hockey Stick concept to large commercial plant application is presented, with an evaluation of scaleup limitations, transient effects, and system design implications.

Hallinan, G.J.; Svedlund, P.E.

1981-01-01T23:59:59.000Z

338

Circumferential cracking of steam generator tubes  

SciTech Connect

On April 28, 1995, the U.S. Nuclear Regulatory Commission (NRC) issued Generic Letter (GL) 95-03, {open_quote}Circumferential Cracking of Steam Generator Tubes.{close_quote} GL 95-03 was issued to obtain information needed to verify licensee compliance with existing regulatory requirements regarding the integrity of steam generator tubes in domestic pressurized-water reactors (PWRs). This report briefly describes the design and function of domestic steam generators and summarizes the staff`s assessment of the responses to GL 95-03. The report concludes with several observations related to steam generator operating experience. This report is intended to be representative of significant operating experience pertaining to circumferential cracking of steam generator tubes from April 1995 through December 1996. Operating experience prior to April 1995 is discussed throughout the report, as necessary, for completeness.

Karwoski, K.J.

1997-04-01T23:59:59.000Z

339

HYDROGEN PRODUCTION FROM PHOTOLYSIS OF STEAM ADSORBED ONTO PLATINIZED SrTiO3  

E-Print Network (OSTI)

PRODUCTION FROM PHOTOLYSIS OF STEAM ADSORBED ONTO PLATINIZEDPRODUCTION FROM PHOTOLYSIS OF STEAM ADSORBED ONTO PLATINIZED

Carr, R.G.

2013-01-01T23:59:59.000Z

340

High Temperature Steam Corrosion of Cladding for Nuclear Applications: Experimental  

SciTech Connect

Stability of cladding materials under off-normal conditions is an important issue for the safe operation of light water nuclear reactors. Metals, ceramics, and metal/ceramic composites are being investigated as substitutes for traditional zirconium-based cladding. To support down-selection of these advanced materials and designs, a test apparatus was constructed to study the onset and evolution of cladding oxidation, and deformation behavior of cladding materials, under loss-of-coolant accident scenarios. Preliminary oxidation tests were conducted in dry oxygen and in saturated steam/air environments at 1000OC. Tube samples of Zr-702, Zr-702 reinforced with 1 ply of a ß-SiC CMC overbraid, and sintered a-SiC were tested. Samples were induction heated by coupling to a molybdenum susceptor inside the tubes. The deformation behavior of He-pressurized tubes of Zr-702 and SiC CMC-reinforced Zr-702, heated to rupture, was also examined.

McHugh, Kevin M; Garnier, John E; Sergey Rashkeev; Michael V. Glazoff; George W. Griffith; Shannong M. Bragg-Sitton

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Connecting Distributed Energy Resources to the Grid: Their Benefits to the DER Owner etc.  

SciTech Connect

The vision of the Distributed Energy Research Program (DER) program of the U.S. Department of Energy (DOE) is that the United States will have the cleanest and most efficient and reliable energy system in the world by maximizing the use of affordable distributed energy resources. Electricity consumers will be able to choose from a diverse number of efficient, cost-effective, and environmentally friendly distributed energy options and easily connect them into the nation's energy infrastructure while providing benefits to their owners and other stakeholders. The long-term goal of this vision is that DER will achieve a 20% share of new electric capacity additions in the United States by 2010, thereby helping to make the nation's electric power generation and delivery system more efficient, reliable, secure, clean, economical, and diverse in terms of fuel use (oil, natural gas, solar, hydroelectric, etc.) and prime mover resource (solar, wind, gas turbines, etc.). Near- and mid-term goals are to develop new technologies for implementing and operating DER and address barriers associated with DER usage and then to reduce costs and emissions and improve the efficiency and reliability of DER. Numerous strategies for meeting these goals have been developed into a research, development, and demonstration (RD&D) program that supports generation and delivery systems architecture, including modeling and simulation tools. The benefits associated with DER installations are often significant and numerous. They almost always provide tangible economic benefits, such as energy savings or transmission and distribution upgrade deferrals, as well as intangible benefits, such as power quality improvements that lengthen maintenance or repair intervals for power equipment. Also, the benefits routinely are dispersed among end users, utilities, and the public. For instance, an end user may use the DER to reduce their peak demand and save money due to lower demand charges. Reduced end user peak demand, in turn, may lower a distribution system peak load such that upgrades are deferred or avoided. This could benefit other consumers by providing them with higher reliability and power quality as well as avoiding their cost share of a distribution system upgrade. In this example, the costs of the DER may be born by the end user, but that user reaps only a share of the benefits. This report, the first product of a study to quantify the value of DER, documents initial project efforts to develop an assessment methodology. The focus of currently available site-specific DER assessment techniques are typically limited to two parties, the owner/user and the local utility. Rarely are the impacts on other stakeholders, including interconnected distribution utilities, transmission system operators, generating system operators, other local utility customers, local and regional industry and business, various levels of government, and the environment considered. The goal of this assessment is to quantify benefits and cost savings that accrue broadly across a region, recognizing that DER installations may have local, regional, or national benefits.

Poore, WP

2003-07-09T23:59:59.000Z

342

Lateral steam flow revealed by a pressure build-up test at the Matsukawa vapor-dominated geothermal field, Japan  

Science Conference Proceedings (OSTI)

Results and discussion of a pressure build-up test at the Matsukawa vapor-dominated geothermal field in north-east Japan are reported. Pressure build-up behavior of three dry steam wells was monitored at the wellhead in October 1986. The observed pressure gradient clearly shows the existence of a lateral steam flow from south-west to north-east in the reservoir. This result suggests that the vapor-dominated reservoir extends further south-west than it is currently being developed. These conclusions are supported by production records and chemical data.

Hanano, M. Sakagawa, Y. (Japan Metals and Chemicals Co. Ltd., 24-Ukai, Takizawa-mura, Iwate 020-01 (JP))

1990-01-01T23:59:59.000Z

343

Downward two-phase flow effects in heat-loss and pressure-drop modeling of steam injection wells  

SciTech Connect

Modelling of the pressure drop and heat loss in steam injection wells has undergone a gradual evolution since the heavy interest in enhanced oil recovery by steam injection in the mid-60's. After briefly reviewing the evolution of steam models this paper presents a model which advances the state-of-the-art of steam modelling. The main advance presented in this paper is modelling the effects of the various flow regimens that occur during steam injection. The paper describes the formulation of a two-phase downward vertical flow pressure drop model which is not limited by the ''no-slip'' homogeneous flow assumptions in most previously published models. By using different correlations for mist, bubble, and slug flow, improved pressure drop calculations result, which in turn improve temperature predictions. The paper describes how the model handles temperature predictions differently in the single and two-phase steam flow situations. The paper also describes special features in the model to account for layered soil properties, soil dry out, cyclic injection, coupling heat losses, and reflux boiling in wet annuli. Two examples problems are presented which illustrate some of these features.

Galate, J.W.; Mitchell, R.F.

1985-03-01T23:59:59.000Z

344

Steam Coal Import Costs - EIA  

Gasoline and Diesel Fuel Update (EIA)

Steam Coal Import Costs for Selected Countries Steam Coal Import Costs for Selected Countries U.S. Dollars per Metric Ton1 (Average Unit Value, CIF2) Country 2001 2002 2003 2004 2005 2006 2007 2008 2009 Belgium 46.96 39.34 39.76 66.29 70.83 70.95 82.81 150.58 NA Denmark 40.78 31.65 50.27 56.29 61.84 59.15 75.20 113.34 NA Finland 40.83 37.08 39.99 58.45 62.80 67.65 72.64 134.21 NA France 45.36 42.59 42.63 64.08 75.23 72.92 84.49 135.53 NA Germany 41.46 36.80 39.00 61.22 72.48 70.12 81.49 138.84 NA Ireland3 45.25 47.88 50.08 80.90 74.91 101.78 125.15 143.08 NA Italy 44.83 41.25 42.45 63.54 73.20 69.16 86.00 143.68 NA Japan 37.95 36.95 34.93 51.48 62.73 63.33 70.92 125.42 NA Netherlands 40.09 35.81 37.27 55.09 68.86 68.57 79.12 133.50 NA

345

Method of drying articles  

DOE Patents (OSTI)

A method of drying a green particulate article includes the steps of: (a) Providing a green article which includes a particulate material and a pore phase material, the pore phase material including a solvent; and (b) contacting the green article with a liquid desiccant for a period of time sufficient to remove at least a portion of the solvent from the green article, the pore phase material acting as a semipermeable barrier to allow the solvent to be sorbed into the liquid desiccant, the pore phase material substantially preventing the liquid desiccant from entering the pores. 3 figs.

Janney, M.A.; Kiggans, J.O. Jr.

1999-03-23T23:59:59.000Z

346

Method of drying articles  

DOE Patents (OSTI)

A method of drying a green particulate article includes the steps of: a. Providing a green article which includes a particulate material and a pore phase material, the pore phase material including a solvent; and b. contacting the green article with a liquid desiccant for a period of time sufficient to remove at least a portion of the solvent from the green article, the pore phase material acting as a semipermeable barrier to allow the solvent to be sorbed into the liquid desiccant, the pore phase material substantially preventing the liquid desiccant from entering the pores.

Janney, Mark A. (Knoxville, TN); Kiggans, Jr., James O. (Oak Ridge, TN)

1999-01-01T23:59:59.000Z

347

Session: Hot Dry Rock  

SciTech Connect

This session at the Geothermal Energy Program Review X: Geothermal Energy and the Utility Market consisted of four presentations: ''Hot Dry Rock - Summary'' by George P. Tennyson, Jr.; ''HDR Opportunities and Challenges Beyond the Long Term Flow Test'' by David V. Duchane; ''Start-Up Operations at the Fenton Hill HDR Pilot Plant'' by Raymond F. Ponden; and ''Update on the Long-Term Flow Testing Program'' by Donald W. Brown.

Tennyson, George P. Jr.; Duchane, David V.; Ponden, Raymond F.; Brown, Donald W.

1992-01-01T23:59:59.000Z

348

Improving steam turbine-gas turbine plants  

SciTech Connect

Leningrad Polytechnic Institute investigated the main characteristics of combined plants according to their structure, determined by very important parameters. The following parameters were selected: utilization factor (ratio of heat added to the steam-water working medium from the heat of the exhaust gases to the entire amount of heat added to the steam-water working medium) and fuel consumption factor (ratio of heat from fuel added to the steam-water working medium to the entire consumption of heat in the combined plant). It is concluded that steam turbine-gas turbine plants working at comparatively low gas temperatures (about 800/sup 0/C) must be constructed as plants of maximum capacity, i.e., with large steam flows. Gas turbine-steam turbine plants with high-temperature gas turbines operating at a high utilization factor (approaching binary plants) ensure a qualitative rise in efficiency and have high flexibility characteristics. They are the most promising power plants. A long-term plan for development of combined plants on the basis of standard steam turbine and gas turbine equipment, the production of which is planned in the USSR and in Comecon countries, is required. This plan must be closely connected with solution of the problem of using coals for gas turbine plants.

Kirillov, I.I.; Arsen' ev, L.V.; Khodak, E.A.; Romakhova, G.A.

1979-01-01T23:59:59.000Z

349

Solid fuel fired oil field steam generators  

Science Conference Proceedings (OSTI)

The increased shortages being experienced in the domestic crude oil supply have forced attention on the production of heavy crude oils from proven reserves to supplement requirements for petroleum products. Since most heavy crudes require heat to facilitate their extraction, oil field steam generators appear to represent a key component in any heavy crude oil production program. Typical oil field steam generator experience in California indicates that approx. one out of every 3 bbl of crude oil produced by steam stimulation must be consumed as fuel in the steam generators to produce the injection steam. The scarcity and price of crude oil makes it desirable to substitute more readily available and less expensive solid fuels for the crude oil which is presently serving as the primary steam generator fuel. Solid fuel firing capability also is of importance because of the substantial amounts of high heating value and low cost petroleum coke available from the processing of heavy crude oil and suitable for use as a steam generator fuel.

Young, W.W.

1982-01-01T23:59:59.000Z

350

"Greening" Industrial Steam Generation via On-demand Steam Systems  

E-Print Network (OSTI)

Both recent economic and environmental conditions in the U.S. have converged to bring about unprecedented attention to energy efficiency and sustainability in the country's industrial sector. Historically, energy costs in the U.S. have been low in comparison to global averages in some measure do to an extended tolerance for externalized costs related to environmental degradation. Consequently, awareness, innovation & implementation of technologies focused on energy efficiency and reduced environmental impact have not kept pace with other industrialized nations. The U.S. is confronted with looming tipping points with respect to energy supply and GHG emissions that represent very tangible constraints on future economic growth and quality of life. A recent 2008 article in Forbes Magazine highlights the top ten most energy efficient economies in the world. The U.S. is conspicuously absent from the list. The U.S. economy, with an estimated energy intensity of 9,000 Btu's/$GDP, is only half as energy efficient as Japan (holding the top spot on the list with an EI of 4,500 Btu's / US$ GDP). The U.S. Department of Energy has initiated the Save Energy Now program to address this by supporting reductions in U.S. industrial energy intensity by 25% by 2020. A recent 2005 survey conducted by Energy & Environmental Analysis, Inc. (EEA) for Oak Ridge National Laboratory indicates that the current U.S. inventory of commercial/industrial boilers stands at around 163,000 units and 2.7 million MMBtu/hr. total fuel input capacity. These boilers consume nearly 8,100 Tbtu per year, representing about 40% of all energy consumed in the commercial/industrial sectors. Moreover, this same survey indicates that 47% of all commercial/industrial boilers in the U.S. are 40+ years old while as many as 76% are 30+ years old. Boilers account for nearly half of commercial / industrial energy consumption and represent some of the most energy intensive systems comprising these sectors. Given the preponderance of aged, obsolete boiler technology currently in service in the U.S., it is critical to raise awareness and examine the role of emerging new technologies to address the energy and environmental challenges inherent with steam generation. In the same way that tank-less / instantaneous water heating systems are eschewing a new era in energy efficiency in the residential sector, compact modular on-demand steam generation systems are poised to support the same kind of transformation in the commercial / industrial sector. This paper will illustrate how emerging on-demand steam generation technologies will play a part in addressing the energy and environmental challenges facing the country's commercial/ industrial sectors and in doing so help to transform the U.S. economy.

Smith, J. P.

2010-01-01T23:59:59.000Z

351

STEPS TO ESTABLISH A REAL-TIME TRANSMISSION MONITORING SYSTEM FOR TRANSMISSION OWNERS AND OPERATORS WITHIN THE  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

STEPS TO ESTABLISH A REAL-TIME TRANSMISSION MONITORING STEPS TO ESTABLISH A REAL-TIME TRANSMISSION MONITORING SYSTEM FOR TRANSMISSION OWNERS AND OPERATORS WITHIN THE EASTERN AND WESTERN INTERCONNECTIONS A REPORT TO CONGRESS PURSUANT TO SECTION 1839 OF THE ENERGY POLICY ACT OF 2005 Prepared by United States Department of Energy & Federal Energy Regulatory Commission February 3, 2006 Report to Congress Joint Report by the Department of Energy and Federal Energy Regulatory Commission on Steps to Establish a Real-Time Transmission Monitoring System for Transmission Owners and Operators within the Eastern and Western Interconnections February 2006 Executive Summary In August 2003, an electrical outage in one state precipitated a cascading blackout across seven other states and as far north as a province in Canada, leaving more than 50 million

352

Impact of injection on reservoir performance in the NCPA steam field at The Geysers  

SciTech Connect

A managed injection program implemented by the NCPA in The Southeast Geysers reservoir continues to positively impact reservoir performance. Injection effects are determined by the application of geochemical and geophysical techniques to track the movement of injectate. This information, when integrated with reservoir pressure, flowrate, and thermodynamic data, is used to quantify the overall performance and efficiency of the injection program. Data analysis indicates that injected water is boiling near the injection wells, without deeper migration, and is recovered as superheated steam from nearby production wells. Injection derived steam (IDS) currently accounts for 25 to 35 percent of total production in the NCPA steamfield. Most importantly, 80 to 100% of the injectate is flashing and being recovered as steam. The amount of IDS has increased since 1988 due to both a change in injection strategy and a drying out of the reservoir. However, significant areas of the reservoir still remain relatively unaffected by injection because of the limited amount of injectate presently available. That the reservoir has been positively impacted in the injection areas is evidenced by a decrease in the rate of pressure decline from 1989 through 1992. Correspondingly, there has been a reduction in the rate of steam flow decline in the areas' production wells. Conversely, little evidence of reservoir cooling or thermal breakthrough is shown even in areas where IDS accounts for 80 percent or more of production. Finally, since injection water is a relatively low-gas source of steam, noncondensible gas concentrations have been reduced in some steam wells located within the injection dominated areas.

Enedy, S.L.; Smith, J.L.; Yarter, R.E.; Jones, S.M.; Cavote, P.E.

1993-01-28T23:59:59.000Z

353

EPRI steam-turbine-related research projects  

SciTech Connect

The current perspective is provided of EPRI-project activities that relate to steam turbine reliability. Compiling status information is a part of the planning effort for continuing projects on turbine rotor reliability, turbine chemistry monitoring and materials behavior, and for the proposed project related to cracking of shrunk-on discs in low pressure nuclear steam turbines. This document includes related work beyond the steam turbine itself to cover those research projects whose scope and results impact the efforts specific to the turbine.

Gelhaus, F.; Jaffee, R.; Kolar, M.; Poole, D.

1978-08-01T23:59:59.000Z

354

ORCENT2. Nuclear Steam Turbine Cycle Analysis  

SciTech Connect

ORCENT2 performs heat and mass balance calculations at valves-wide-open design conditions, maximum guaranteed rating conditions, and an approximation of part-load conditions for steam turbine cycles supplied with throttle steam, characteristic of contemporary light-water reactors. The program handles both condensing and back-pressure turbine exhaust arrangements. Turbine performance calculations are based on the General Electric Company method for 1800-rpm large steam turbine-generators operating with light-water-cooled nuclear reactors. Output includes all information normally shown on a turbine-cycle heat balance diagram.

Fuller, L.C. [Oak Ridge National Lab, TN (United States)

1979-07-01T23:59:59.000Z

355

Condensing Heat Exchangers Optimize Steam Boilers  

E-Print Network (OSTI)

The development of fluorocarbon resin covered tubes has advanced to the point where full scale marketing in connection with condensing heat exchangers has begun. Field installations show simple paybacks of one to one and a half years with resulting steam boiler fuel to steam efficiencies in excess of 90%. The studies and evaluations done to date indicate that units of this type will be cost effective in sizes ranging from 10,000 to 300,0000 steam per hour as long as cold makeup water is available for preheating with the waste flue gases.

Sullivan, B.; Sullivan, P. A.

1983-01-01T23:59:59.000Z

356

Solar Augmented Steam Cycles: 2010 Industry Update  

Science Conference Proceedings (OSTI)

Several studies were performed to evaluate a range of solar augmented steam cycle design options. All the designs use steam generated by a solar field in a conventional steam cycle, either offsetting some of the fuel required to generate power or boosting plant power output. The scope of the studies included a conceptual design modeling effort to evaluate a broad range of solar integration design options for biomass and natural gas combined-cycle (NGCC) power plants and two detailed case studies at NGCC ...

2010-12-23T23:59:59.000Z

357

Aerothermodynamics of low pressure steam turbines and condensers  

SciTech Connect

This book presents papers on steam turbines and steam condensers. Topics considered include the design of modern low pressure steam turbines, throughflow design methods, three-dimensional flow calculations, the calculation of wet steam stages, aerodynamic development of turbine blades, turbine performance measurement, turbine exhaust system design, and condensers for large turbines.

Moore, M.J.; Sieverding, C.H.

1987-01-01T23:59:59.000Z

358

Economic Analysis of "Steam-Shock" and "Pasteurization"  

E-Print Network (OSTI)

Economic Analysis of "Steam-Shock" and "Pasteurization" Processes for Oyster Shucking JOHN W. BROWN Introduction "Steam-shock" is an oyster shucking process that uses steam to relax the oyster's adductor muscle of the shucking process as in integral part of the operation of an existing oyster-shucking house. The term "steam

359

USE OF COAL DRYING TO REDUCE WATER CONSUMED IN PULVERIZED COAL POWER PLANTS  

SciTech Connect

This is the sixth Quarterly Report for this project. The background and technical justification for the project are described, including potential benefits of reducing fuel moisture, prior to firing in a pulverized coal boiler. Coal drying experiments were performed with a Powder River Basin coal to measure the effects of fluidization velocity and drying temperature on rate of drying in a batch drying process. Comparisons to computational results using the batch bed drying model show good agreement. Comparisons to drying results with North Dakota lignite at the same process conditions confirm the lignite dries slightly more rapidly than the PRB. Experiments were also carried out to determine the effects of inlet air humidity on drying rate. The specific humidity ranged from a value typical for air at temperatures near freezing to a value for 30 C air at 90 percent relative humidity. The experimental results show drying rate is strongly affected by inlet air humidity, with the rate decreasing with more humid inlet air. The temperature of the drying process also plays a strong role, with the negative impacts of high inlet moisture being less of a factor in a higher temperature drying process. Concepts for coal drying systems integrated into a power plant were developed. These make use of hot circulating cooling water from the condenser, steam extraction from the turbine cycle and thermal energy extracted from hot flue gas, in various combinations. Analyses are under way to calculate the effects of drying system design and process conditions on unit performance, emissions, and cooling tower makeup water.

Edward K. Levy; Nenad Sarunac; Wei Zhang

2004-07-01T23:59:59.000Z

360

EVALUATION OF KANIGEN, ELECTROLESS NICKEL PLATING FOR STEAM SIDE OF A SODIUM COMPONENT STEAM GENERATOR  

SciTech Connect

The evaluation of Kanigen electroless nickel plating for surfaces in contact with water and steam in a sodium-heated Type 316 stainless steel steam generator is reported. The purpose of the coating is to afford protection from stress corrosion cracking originating on the water-steam side of the unit. It is concluded that the Kanigen coating does not afford adequate protection for the service conditions. (D.L.C.)

1961-02-15T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Natural circulation steam generator model for optimal steam generator water level control  

SciTech Connect

Several authors have cited the control of steam generator water level as an important problem in the operation of pressurized water reactor plants. In this paper problems associated with steam generator water level control are identified, and advantages of modern estimation and control theory in dealing with these problems are discussed. A new state variable steam generator model and preliminary verification results using data from the loss of fluid test (LOFT) plant are also presented.

Feeley, J.J.

1979-06-01T23:59:59.000Z

362

Steam Generator Management Program: Proceedings of the 26th Steam Generator NDE Workshop  

Science Conference Proceedings (OSTI)

This year's Steam Generator nondestructive evaluation (NDE) Workshop took place in Big Sky, Montana, on July 1618, 2007, and included one full day and two half days of presentations. Attendees included representatives from domestic and international nuclear utilities, nuclear steam supply system (NSSS) vendors, NDE service and equipment organizations, research laboratories, and regulatory bodies. This annual workshop serves as a forum for NDE specialists to gather and discuss current steam generator NDE ...

2007-08-29T23:59:59.000Z

363

Steam Generator Management Program: Investigation of Steam Generator Secondary-Side Degradation  

Science Conference Proceedings (OSTI)

This document reviews and discusses age-related degradation that has occurred in the carbon steel internal components in the steam drums of Westinghouse steam generators (SGs), especially in original and early replacement SGs. The degradation is characterized by gradual thinning (loss of material) that is generally localized in the components as a result of exposure to high-velocity steam-water mixtures. Material loss from internal components has been noted during secondary-side visual inspections of ori...

2011-09-20T23:59:59.000Z

364

Steam Generator Management Program: Flaw Tolerance Evaluation of the Steam Generator Channel Head  

Science Conference Proceedings (OSTI)

 Indications have previously been reported in the steam generator divider plate at operating plants outside the United States. The function of the divider plate in most steam generators is to separate the cold and hot legs of the channel head as the primary water enters the steam generator so that the primary coolant flows up into the tubes. As such, the divider plate is not considered a primary pressure ...

2013-04-25T23:59:59.000Z

365

Steam Generator Management Program: Steam Generator In Situ Pressure Test Guidelines, Revision 4  

Science Conference Proceedings (OSTI)

Information in this document provides guidance for the performance of in situ pressure testing of steam generator tubes. In situ pressure testing refers to hydrostatic pressure tests performed on installed tubing in the field. Such testing is considered a direct means of evaluating tube structural and leakage integrity. In situ pressure testing can be used to support condition monitoring of steam generator tube integrity.This is a required document for a steam generator program developed ...

2012-10-02T23:59:59.000Z

366

IMPROVEMENTS IN OR RELATING TO STEAM GENERATING PLANT  

SciTech Connect

A steam generating plant for marine vessels includes a steam superheater (nuclear reactor, perhaps) from which steam is ducted to the point of use (heat exchanger, etc.). A steam generator receiving the condensed steam from the point of use uses steam from the superheater to evaporate the condensate. The superheated steam used in the evaporation is compressed by a turbo-compressor and directed into the superheater. The condensate evaporated in the generator is used to drive the turbo-compressor. (D.C.W.)

Kendon, M.H.

1963-07-03T23:59:59.000Z

367

IMPROVEMENTS IN AND RELATING TO STEAM CONDENSER INSTALLATIONS FOR STEAM TURBINE POWER PLANT  

SciTech Connect

A steam condenser arrangement for turbine power plants which have excess steam at times is described. A dump condenser with cooling water connections in parallel with steam turbine condensers receives surplus steam. Cooling water from the turbine condensers is mixed with coolant from the dump condenser so that a predetermined maximum temperature is not exceeded. The quantity of cooling water passing through the dump condenser is a proportion of the total circulating water requirements of the condenser installation, and the pressure drop across it is less than that across the main condensers. (T.R.H.)

1960-05-18T23:59:59.000Z

368

Extraction Steam Controls at EPLA-W  

E-Print Network (OSTI)

ExxonMobil's Baton Rouge site encompasses a world-scale refinery, chemical plant and third party power station. Historically, inflexible and unreliable control systems on two high-pressure, extracting/condensing steam turbines prevented the site from ful

Brinker, J. L.

2004-01-01T23:59:59.000Z

369

Reliability Assessment of North American Steam Turbines  

Science Conference Proceedings (OSTI)

This survey provides statistics related to the reliability and maintenance of fossil-fueled steam turbines in the continental United States. The analysis focuses primarily on active turbines larger than 200 MW.

2002-04-24T23:59:59.000Z

370

A small pelton turbine for steam turbocharger  

SciTech Connect

The use of exhaust gas turbocharger for internal combustion engines is usually accompanied by mechanical loss. This loss is due to the raise of exhaust gas back pressure with the increase of engine speed. This back pressure prevents the discharge of the exhaust gas from the engine and causes mechanical loss. To avoid this undesirable phenomenon, a Clausius-Rankine cycle is used. In this case the thermal energy in the exhaust gas is used to vaporise water in a steam generator. The generated steam expands in a steam turbocharger which supercharges the engine. A small Pelton steam turbine has been designed and fabricated. The expected output for this small turbine is 10 kW. A computer program has been prepared to estimate the values of optimum cycle parameters.

Rautenberg, M.; Abdelkader, M.; Malobabic, M.; Mobarak, A.

1984-08-01T23:59:59.000Z

371

Standard Steam Trust LLC | Open Energy Information  

Open Energy Info (EERE)

Steam Trust LLC Steam Trust LLC (Redirected from Standard Steam Trust) Jump to: navigation, search Name Standard Steam Trust LLC Place Denver, Colorado Sector Geothermal energy Product Subsidiary of Denver-based geothermal project developer, Terra Caliente. Coordinates 39.74001°, -104.992259° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":39.74001,"lon":-104.992259,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

372

Downhole steam generator at Kern River  

SciTech Connect

Testing of a prototype down-hole steam generator for use in enhanced oil recovery (EOR) operations has begun at a heavy oil reservoir in the Kern River oil field in California. Steam and combustion gases are directed into an 800-ft-deep reservoir through a standard surface steam delivery system, although the system is designed to function at depths to 4500 ft. Present steam injection techniques require one-third of the oil recovered to be used to fuel the injection system, and the boilers require scrubbers to control emissions to specifications. The down-hole system is expected to use only 2/3 as much fuel as the conventional systems and to have less impact on air quality.

Rintoul, B.

1980-05-01T23:59:59.000Z

373

Steam Turbine Hydraulic Control system Maintenance Guide  

Science Conference Proceedings (OSTI)

Steam turbine hydraulic control system maintenance problems have been a significant factor in plant power reductions, shutdowns, and lost generation. This guide provides recommendations to improve the reliability of the hydraulic components and fluid.

1996-12-31T23:59:59.000Z

374

Remote NDE Technology for Steam Turbines  

Science Conference Proceedings (OSTI)

Remote nondestructive evaluation technology (NDE) for steam turbines has potential for use as an alternative to inspections requiring extensive machine disassembly and for use during short-term outages, to provide an interim look at machine operability.

2002-11-21T23:59:59.000Z

375

Savings in Steam Systems (A Case Study)  

E-Print Network (OSTI)

Armstrong Service Inc. (ASI) conducted an engineered evaluation at an Ammonium Nitrate Manufacturing facility during the Fall of 1999. This plant manufactures Nitric Acid and high and low density Ammonia Nitrate. The purpose of this evaluation is to identify energy losses and system improvements in the steam and condensate systems. Steam system improvements focus on lowering the cost of steam, wherever possible, with paybacks of 3 years or less. Overall, this ASI evaluation identifies six (6) steam savings proposals with an average simple payback of 2.9 years. This evaluation also identifies one system deficiency that will lead to unnecessary expenditures if allowed to continue, but would help to increase production if the suggested improvement was implemented. The following report details the individual findings and outlines the corrections needed. The savings generated from these improvements will more than pay for themselves in short order.

DeBat, R.

2001-05-01T23:59:59.000Z

376

Consider Steam Turbine Drives for Rotating Equipment  

SciTech Connect

This revised ITP tip sheet on steam turbine drives for rotating equipment provides how-to advice for improving the system using low-cost, proven practices and technologies.

2006-01-01T23:59:59.000Z

377

Design of a heat recovery steam generator  

SciTech Connect

A gas turbine in the size range of 20,000 hp (14.9 MW) was retrofitted with a heat recovery steam generator (HRSG). The HRSG produces high pressure superheated steam for use in a steam turbine. Supplementary firing is used to more than double the steam production over the unfired case. Because of many unusual constraints, an innovative design of the HRSG was formulated. These design constraints included: a wide range of operating conditions was to be accommodated; very limited space in the existing plant; and a desire to limit the field construction work necessary in order to provide a short turnaround time. This paper discusses the design used to satisfy these conditions.

Logeais, D.R.

1984-06-01T23:59:59.000Z

378

The revolutionary impact of the steam engine  

E-Print Network (OSTI)

Sitting with a model of Stephenson’s Rocket, Simon Schaffer reflects on the steam revolution and how it changed the world in the nineteenth century in so many different ways....

Dugan, David

2004-08-18T23:59:59.000Z

379

How did the Rocket steam engine work?  

E-Print Network (OSTI)

Simon Schaffer talks to a museum curator at the York railway museum about the way in which steam engines worked and the imagination and technical ability of George Stephenson....

Dugan, David

2004-08-17T23:59:59.000Z

380

How solvent vapors can improve steam floods  

Science Conference Proceedings (OSTI)

Thermal recovery methods depend for their success on the viscosity reduction of heavy crude oils at high temperatures. The viscosity of a heavy oil can also be reduced if it is diluted with a low-viscosity solvent, such as one of the lighter hydrocarbons. It is not surprising that there has been considerable interest in combining the two methods. The process of injecting vaporized solvent with the steam for a gravity drainage type recovery is described here along with a description of the particular phase behavior of steam/solvent mixtures which is beneficial to the process. And computer simulations which compare steam-only and steam/solvent floods under Athabasca-type conditions are overviewed.

Vogel, J. [Vogel, (Jack), Seabrook, TX (United States)

1996-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Steam turbine upgrading: low-hanging fruit  

Science Conference Proceedings (OSTI)

The thermodynamic performance of the steam turbine, more than any other plant component, determines overall plant efficiency. Upgrading steam path components and using computerized design tools and manufacturing techniques to minimise internal leaks are two ways to give tired steam turbines a new lease on life. The article presents three case studies that illustrate how to do that. These are at Unit 1 of Dairyland's J.P. Madgett Station in Alma, WI, a coal-fired subcritical steam plant; the four units at AmerenUE's 600 MW coal-fired Labadie plant west of St. Louis; and Unit 3 of KeyPlan Corp's Northport Power Station on Long Island. 8 figs.

Peltier, R.

2006-04-15T23:59:59.000Z

382

Reservoir performance characterized in mature steam pattern  

Science Conference Proceedings (OSTI)

A detailed reservoir description provided new insight in an investigation of a ten-year-old steam flood. Mobil Oil Corporation conducted this study of the Pleistocene upper Tulare sands in South Belridge field, located in the San Joaquin basin, Kern County, California. The study area is on the gently dipping (6/degrees/) southwestern flank of the South Belridge anticline. Wireline logs from 19 wells in a 10-ac (660 ft x 660 ft) pattern were correlated in detail. Seven post-steam conventional cores (1523 ft) aided (1) the evaluation of vertical and lateral steam-sweep efficiency, (2) evaluation of reservoir and fluid changes due to steam, (3) influence of lithofacies in reservoir quality, and (4) provided insight to the three-dimensional reservoir flow-unit geometries.

Miller, D.D.; McPherson, J.G.; Covington, T.E.

1989-04-01T23:59:59.000Z

383

MISR -- Solar and steam for industry  

SciTech Connect

The goal of the MISR project is to assist industry in developing viable Solar Energy Systems which have high reliability and low cost because they do not require custom engineering and installation for each industrial site. The collector field, piping and steam generation equipment are pre-engineered to be suitable for a wide range of industrial steam applications. The approach of the MISR project is twofold: to develop line-focus industrial solar thermal energy systems which, like conventional packaged steam boilers, are based on the modular concept; and to install and operate a number (10 or less) of these systems at existing industrial plants, supplementing steam produced by conventional boilers. The project is briefly described.

1981-12-31T23:59:59.000Z

384

Greenville Steam Biomass Facility | Open Energy Information  

Open Energy Info (EERE)

Greenville Steam Biomass Facility Greenville Steam Biomass Facility Jump to: navigation, search Name Greenville Steam Biomass Facility Facility Greenville Steam Sector Biomass Location Piscataquis County, Maine Coordinates 45.7049857°, -69.3375071° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":45.7049857,"lon":-69.3375071,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

385

Specific features of geothermal steam turbine control and emergency system  

SciTech Connect

There are significant construction as well as operational differences between geothermal and conventional steam turbines. These result in specific features associated with geothermal steam turbine control and emergency system. Several aspects of geothermal steam turbine control have been considered. Some proposals of geothermal steam turbine control have been presented. Among others the following operation modes have been considered: Driving turbine, driving well, turbine power and well steam pressure coupled control.

Domachowski, Z.; Gutierrez, A.

1986-01-01T23:59:59.000Z

386

IMPROVEMENTS IN OR RELATING TO STEAM-OPERATED POWER PLANT  

SciTech Connect

A nuclear power plant is designed in which the reactor is steam-cooled and radioactivity is removed from the steam before entering the turbine. The plant has a steam circuit in which the steam from the reactor is passed through one flow path of a heat exchanger and then part of this steam is passed through contact washing equipment before being reheated in a second flow path of the heat exchanger and being led to the turbine. (D.L.C.)

Bauer, S.G.; Kendon, M.H.

1962-09-19T23:59:59.000Z

387

Procedural and administrative techniques to improve steam generator layup  

Science Conference Proceedings (OSTI)

A number of utilities have been working to improve layup techniques for steam generators; especially once-through steam generators. There are two main elements to successful layup of steam generators: (a) starting with and maintaining high-quality layup water and (b) minimizing the exposure of steam generator internals to air. Specific procedural and administrative techniques have been developed to ensure these two elements are achieved. These appear to be applicable to most steam generators.

Carrick, B.J.

1985-01-01T23:59:59.000Z

388

Apparatus and methods of reheating gas turbine cooling steam and high pressure steam turbine exhaust in a combined cycle power generating system  

DOE Patents (OSTI)

In a combined cycle system having a multi-pressure heat recovery steam generator, a gas turbine and steam turbine, steam for cooling gas turbine components is supplied from the intermediate pressure section of the heat recovery steam generator supplemented by a portion of the steam exhausting from the HP section of the steam turbine, steam from the gas turbine cooling cycle and the exhaust from the HP section of the steam turbine are combined for flow through a reheat section of the HRSG. The reheated steam is supplied to the IP section inlet of the steam turbine. Thus, where gas turbine cooling steam temperature is lower than optimum, a net improvement in performance is achieved by flowing the cooling steam exhausting from the gas turbine and the exhaust steam from the high pressure section of the steam turbine in series through the reheater of the HRSG for applying steam at optimum temperature to the IP section of the steam turbine.

Tomlinson, Leroy Omar (Niskayuna, NY); Smith, Raub Warfield (Ballston Lake, NY)

2002-01-01T23:59:59.000Z

389

Control system for fluid heated steam generator  

DOE Patents (OSTI)

A control system for controlling the location of the nucleate-boiling region in a fluid heated steam generator comprises means for measuring the temperature gradient (change in temperature per unit length) of the heating fluid along the steam generator; means for determining a control variable in accordance with a predetermined function of temperature gradients and for generating a control signal in response thereto; and means for adjusting the feedwater flow rate in accordance with the control signal.

Boland, James F. (Bonneville County, ID); Koenig, John F. (Idaho Falls, ID)

1985-01-01T23:59:59.000Z

390

Oxidation of advanced steam turbine alloys  

SciTech Connect

Advanced or ultra supercritical (USC) steam power plants offer the promise of higher efficiencies and lower emissions. Current goals of the U.S. Department of Energy’s Advanced Power Systems Initiatives include coal generation at 60% efficiency, which would require steam temperatures of up to 760°C. This research examines the steamside oxidation of advanced alloys for use in USC systems, with emphasis placed on alloys for high- and intermediate-pressure turbine sections.

Holcomb, G.R.; Covino, B.S., Jr.; Bullard, S.J.; Ziomek-Moroz, M.

2006-03-01T23:59:59.000Z

391

Control system for fluid heated steam generator  

DOE Patents (OSTI)

A control system for controlling the location of the nucleate-boiling region in a fluid heated steam generator comprises means for measuring the temperature gradient (change in temperature per unit length) of the heating fluid along the steam generator; means for determining a control variable in accordance with a predetermined function of temperature gradients and for generating a control signal in response thereto; and means for adjusting the feedwater flow rate in accordance with the control signal.

Boland, J.F.; Koenig, J.F.

1984-05-29T23:59:59.000Z

392

Heat Recovery Steam Generator Materials Selection Guideline  

Science Conference Proceedings (OSTI)

A considerable number of failures have occurred over the past decade in heat recovery steam generators (HRSGs). Many of these failures are attributed to poor design, improper operation, poor fabrication, or poor installation practices, but a number of them are attributed directly to improper material selection. In March 2004, the Electric Power Research Institute (EPRI) published the first heat recovery steam generator materials selection and repair guidelines (HRSG Material Selection and Repair Guidelin...

2010-12-19T23:59:59.000Z

393

Enhanced Chloride Monitoring for Steam Condensate Samples  

Science Conference Proceedings (OSTI)

The objective of this project was to develop to the proof-of-concept stage a system that enables the quantification of chloride (Cl) in turbine steam condensate samples. The chloride quantification system is intended to serve as an alternative to online chromatography for chloride concentration monitoring. The conceptual approach was to concentrate the ions in the steam condensate, by a predetermined factor, to a level that allowed accurate detection of chloride by ion selective electrodes (ISEs). The ab...

2012-01-31T23:59:59.000Z

394

Heat Recovery Steam Generator Cycle Chemistry Instrumentation  

Science Conference Proceedings (OSTI)

Effective monitoring of the purity of water and steam is an integral part of any productive cycle chemistry monitoring program. The Electric Power Research Institute's (EPRI's) heat recovery steam generator (HRSG) cycle chemistry guidelines identified a group of core monitoring parameters that are considered the minimum requirements. Meeting these requirements is part of EPRI's cycle chemistry benchmarking criteria for HRSGs. In addition to the core parameters, many chemistry parameters might need to be ...

2010-11-19T23:59:59.000Z

395

Steam System Improvement: A Case Study  

E-Print Network (OSTI)

Along with the shortage of conventional energy sources, efforts have been sought to use energy in a rational manner. Whereas the biggest energy consumption is in the industrial sector, various techniques to reduce energy have been searched. For industries, this will result in the reduction of production cost. In industry where steam is utilized, the steam production and distribution system consumes a significant portion of energy. Therefore, optimization of steam system is among the biggest energy saving potential in industry. The optimization measures can be categorized into two methods, i.e. (1) no cost/low cost that can be done through a better maintenance and improvement of operating conditions, and (2) major improvement that requires a significant amount of investment, that includes the modification of process and major equipment. Since energy saving is an endless effort, new levels of energy efficiency standards are being set year after year. Therefore, repeated studies should be made to identify energy saving potential. Modern instruments allow the energy specialists to conduct an in-depth survey to identify energy performance. This paper highlights the findings of the study in a steam generation and distribution system of a crude oil stabilization unit. With the annual budget of $8.3 million, the unit is handling about 600,000 barrels crude oil per day from an offshore platform. The study identified an opportunity of annual saving amounting to $1,115,300. Though the finding is specific to a single site, the basics of steam system analysis are applicable to any steam system. The steam system should be reviewed year after year to identify more energy wastes and to improve efficiency of steam system, thus reducing the energy cost. At the same time this will also help save the environment.

Venkatesan, V. V.; Leigh, N.

1998-04-01T23:59:59.000Z

396

Steam Turbine Electronic Overspeed Protection System  

Science Conference Proceedings (OSTI)

BackgroundThe risk of turbine-generator destructive overspeed can be mitigated by employing protection systems that act to rapidly isolate the steam supply in the event of separation from the grid. These systems are the final line of defense against overspeed, and they are deployed separately from the systems used to control turbine load and speed during synchronized operation. Most steam turbines in operation today were commissioned with a mechanical trip device that ...

2013-12-23T23:59:59.000Z

397

Design and Performance Aspects of Steam Generators  

E-Print Network (OSTI)

Packaged steam generators are widely used in process and power plants. They are also used as standby boilers in cogeneration/combined cycle plants. The general feeling among consultants, plant engineers and end users is that packaged steam generators are "standard" or "off-the-shelf items", that there exists a model number for a given steam capacity and one has to live with whatever performance is offered by the boiler vendor. Unfortunately, boiler suppliers also encourage specifying of steam generators based on standard, pre-packaged designs. A "standard" boiler has several limitations such as pre-determined furnace dimensions, tube length, surface area, tube spacings etc, which may or may not be the optimum choice for a given steam demand, particularly when today's emission levels have to be met. Also, operating costs, which form a significant portion of overall costs, are ignored by consultants when evaluating various designs for possible purchase. This paper highlights the importance of custom designing packaged steam generators and the resulting benefits from boiler performance viewpoint.

Ganapathy, V.

1994-04-01T23:59:59.000Z

398

An optical technique for characterizing the liquid phase of steam at the exhaust of an LP turbine  

SciTech Connect

Optical observation of velocity and size of water droplets in powerplant steam has several applications. These include the determination of steam wetness fraction, mass flow rate, and predicting erosion of turbine blades and pipe elbows. The major advantages of optical techniques are that they do not interfere with the flow or perturb the observation. This paper describes the measurement of the size and velocity of particles based on the observation and analysis of visibility patterns created by backscattered circularly polarized light. The size of latex particles in a dry nitrogen stream was measured in the laboratory. Visibility patterns of water droplets were observed in the low pressure turbine of Unit 6 of Alabama Power`s Gorgas Steam Plant.

Kercel, S.W.; Simpson, M.L. [Oak Ridge National Lab., TN (US); Azar, M. [Tennessee Technological Univ., Cookeville, TN (US); Young, M. [Alabama Power, Parrish, AL (US)

1993-06-01T23:59:59.000Z

399

Materials Performance in USC Steam  

SciTech Connect

Goals of the U.S. Department of Energy's Advanced Power Systems Initiatives include power generation from coal at 60% efficiency, which requires steam conditions of up to 760 C and 340 atm. Towards this end, further validation of a previously developed chromia evaporation model is shown by examining the reactive evaporation effects resulting from exposure of Haynes 230 and Haynes 282 to moist air environments as a function of flow rate and water content. These two alloys differ in Ti and Mn contents, which may form outer layers of TiO{sub 2} or Cr-Mn spinels. This would in theory decrease the evaporation of Cr{sub 2}O{sub 3} from the scale by decreasing the activity of chromia at the scale surface, and be somewhat self-correcting as chromia evaporation concentrates the Ti and Mn phases. The apparent approximate chromia activity was found for each condition and alloy that showed chromia evaporation kinetics. As expected, it was found that increasing the gas flow rate led to increased chromia evaporation and decreased chromia activity. However, increasing the water content in moist air increased the evaporation, but results were mixed with its effect on chromia activity.

Gordon R. Holcomb, NETL Joesph Tylczak, NETL Rongxiang (Rachel) Hu, NETL and URS Corp

2011-09-15T23:59:59.000Z

400

Materials Performance in USC Steam  

SciTech Connect

Goals of the U.S. Department of Energy’s Advanced Power Systems Initiatives include power generation from coal at 60% efficiency, which requires steam conditions of up to 760 °C and 340 atm. Towards this end, further validation of a previously developed chromia evaporation model is shown by examining the reactive evaporation effects resulting from exposure of Haynes 230 and Haynes 282 to moist air environments as a function of flow rate and water content. These two alloys differ in Ti and Mn contents, which may form outer layers of TiO{sub 2} or Cr-Mn spinels. This would in theory decrease the evaporation of Cr{sub 2}O{sub 3} from the scale by decreasing the activity of chromia at the scale surface, and be somewhat self-correcting as chromia evaporation concentrates the Ti and Mn phases. The apparent approximate chromia activity was found for each condition and alloy that showed chromia evaporation kinetics. As expected, it was found that increasing the gas flow rate led to increased chromia evaporation and decreased chromia activity. However, increasing the water content in moist air increased the evaporation, but results were mixed with its effect on chromia activity.

Gordon R. Holcomb, NETL

2011-09-15T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

System and method for individually testing valves in a steam turbine trip control system  

SciTech Connect

This patent describes a steam turbine power plant. It comprises: a steam generator; a steam turbine adapted to receive steam form the steam generator; a throttle valve for regulating the flow of the steam received by the steam turbine; and an electro-hydraulic trip control system for causing the throttle valve to close when a predetermined condition has been reached.

Hurley, J.D.

1992-07-28T23:59:59.000Z

402

GENERATION, TRANSPORT AND DEPOSITION OF TUNGSTEN-OXIDE AEROSOLS AT 1000 C IN FLOWING AIR-STEAM MIXTURES.  

SciTech Connect

Experiments were conducted to measure the rates of oxidation and vaporization of pure tungsten rods in flowing air, steam and air-steam mixtures in laminar flow. Also measured were the downstream transport of tungsten-oxide condensation aerosols and their region of deposition, including plateout in the superheated flow tube, rainout in the condenser and ambient discharge which was collected on an array of sub-micron aerosol filters. The nominal conditions of the tests, with the exception of the first two tests, were tungsten temperatures of 1000 C, gas mixture temperatures of 200 C and wall temperatures of 150 C to 200 C. It was observed that the tungsten oxidation rates were greatest in all air and least in all steam, generally decreasing non-linearly with increasing steam mole fraction. The tungsten oxidation rates in all air were more than five times greater than the tungsten oxidation rates in all steam. The tungsten vaporization rate was zero in all air and increased with increasing steam mole fraction. The vaporization rate became maximum at a steam mole fraction of 0.85 and decreased thereafter as the steam mole fraction was increased to unity. The tungsten-oxide was transported downstream as condensation aerosols, initially flowing upwards from the tungsten rod through an 18-inch long, one-inch diameter quartz tube, around a 3.5-inch radius, 90{sup o} bend and laterally through a 24-inch horizontal run. The entire length of the quartz glass flow path was heated by electrical resistance clamshell heaters whose temperatures were individually controlled and measured. The tungsten-oxide plateout in the quartz tube was collected, nearly all of which was deposited at the end of the heated zone near the entrance to the condenser which was cold. The tungsten-oxide which rained out in the condenser as the steam condensed was collected with the condensate and weighed after being dried. The aerosol smoke which escaped the condenser was collected on the sub-micron filter assemblies. There was no aerosol generation for the case of all air, so the plateout, condensate and smoke were all zero. For the case of all steam, there was very little plateout in the superheated regions (several percent) and the rest of the aerosol was collected in the condensate from the condenser. There was no smoke discharge into the filters. For the experiments with intermediate air-steam fractions, there was some aerosol plateout, considerable aerosol in the condensate and aerosol smoke discharged from the condenser with the escaping air.

GREENE,G.A.; FINFROCK,C.C.

2001-10-01T23:59:59.000Z

403

Energy from hot dry rock  

DOE Green Energy (OSTI)

The Hot Dry Rock Geothermal Energy Program is described. The system, operation, results, development program, environmental implications, resource, economics, and future plans are discussed. (MHR)

Hendron, R.H.

1979-01-01T23:59:59.000Z

404

Potential use of dry cooling in support of advanced energy generation systems  

SciTech Connect

Advanced energy technologies were investigated for filling the energy supply and demand gap, including fuel cells, thermionic converters, and fusion. Technologies that have the potential for supplying energy in the future are solar, geothermal, coal gasification and liquefaction, clean solid fuel from coal, and oil shale. Results are presented of an analysis of the advanced energy generation systems, the potential for using dry cooling, and the waste heat generation characteristics of the advanced technologies. The magnitude of the waste heat expected to be generated indicates the following percentages of total cooling requirements would be needed by advanced energy technologies: (a) 1% to 2% in 1985, (b) 17% to 40% in 2000, and (c) 24% to 76% in 2025. Dry cooling could be required for flashed steam and dry steam geothermal plants if balancing withdrawal and reinjection of the geothermal fluid becomes a requirement. Binary cycle geothermal plants and plants using the hot dry rocks geothermmal resource are even more likely to require dry cooling since these plants will need an outside source of water. Solar central tower plants have a high potential for the use of dry cooling since they are likely to be located in the Southwest where water availability problems are already apparent. The high water consumption associated with the projected synthetic fuel production levels indicates that dry cooling will be desirable, perhaps even mandatory, to achieve a high level of synthetic fuel production. In the year 2000, between 2.5 and 13 GW of electrical energy produced by advanced power generation systems may require dry cooling. In the year 2025, this requirement may increase to between 4.5 and 81 GW/sub e/.

Mayer, D.W.; Arnold, E.M.; Allemann, R.T.

1979-09-01T23:59:59.000Z

405

Steam Generator Management Program: Production of Steam Generator Tubing Flaws by Laboratory Autoclave Exposures  

Science Conference Proceedings (OSTI)

Qualification of a technique for the examination of steam generator tubing requires realistic flaws that are either pulled from service or produced in the laboratory. Due to the scarcity of pulled tube specimens, an effort was undertaken to produce realistic flaws in a laboratory environment. The ability to produce cracks in the laboratory was explored in doped steam, acidic, and caustic environments. These ...

2013-09-24T23:59:59.000Z

406

Boiler Efficiency vs. Steam Quality- The Challenge of Creating Quality Steam Using Existing Boiler Efficiencies  

E-Print Network (OSTI)

A boiler works under pressure and it is not possible to see what is happening inside of it. The terms "wet steam" and "carry over" are every day idioms in the steam industry, yet very few people have ever seen these phenomena and the actual water movement inside a boiler has remained highly speculative. This paper and support test video of actual boiler operations will illustrate the effects steam quality vs. boiler efficiency during different boiler and steam system demands. There are four different operating situations that effect the steam quality. Each of the following situation will be described in detail using visual aids and supporting literature: Case I: On/Off Feedwater Control: Wide swings in the water level of the boiler can result in unnecessary low water alarms and shut downs. Case II: Reduced Operating Pressure: By running a boiler at a lower pressure, the boiling action within the boiler becomes much more violent causing water to be carried over in to the steam system. Case III: A Demand of 15% over Capacity: Over loading a boiler will cause excessive amounts of water to be carried along with the steam into the system. Case IV: TDS Control: Without proper control of IDS within the boiler carry-over of water into the steam system will occur causing damage to equipment and/or waterhammer.

Hahn, G.

1998-04-01T23:59:59.000Z

407

DOE's BestPractices Steam End User Training Steam End User Training  

E-Print Network (OSTI)

steam systems - Measure boiler efficiency - Estimate the magnitude of specific boiler losses - Identify and prioritize areas of boiler efficiency improvement - Recognize the impacts of fuel selection Measurements] Boiler o Flue gas temperature o Flue gas oxygen content o Boiler fuel flow o Boiler steam

Oak Ridge National Laboratory

408

Development and Application of Advanced Models for Steam Hydrogasification: Process Design and Economic Evaluation  

E-Print Network (OSTI)

Recovery Steam Generator (HRSG) to make additional steam foras electricity through HRSG and steam cycle in the steamof FT liquids distribution HRSG CO 2 capture Heat exchanger

Lu, Xiaoming

2012-01-01T23:59:59.000Z

409

Heat Transfer Limitations in Hydrogen Production Via Steam Reformation: The Effect of Reactor Geometry  

E-Print Network (OSTI)

Ratio Parameters in Steam-Reforming Hydrogen productionan Insufficient Parameter in the Steam-Reforming Process,”Impurities on the Methanol Steam-Reforming Process for Fuel

Vernon, David R.; Davieau, David D.; Dudgeon, Bryce A.; Erickson, Paul A.

2006-01-01T23:59:59.000Z

410

A Better Steam Engine: Designing a Distributed Concentrating Solar Combined Heat and Power System  

E-Print Network (OSTI)

Figures A typical wet steam Rankine cycle on a temperature-A Better Steam Engine: Designing a Distributed Concentrating2011 Abstract A Better Steam Engine: Designing a Distributed

Norwood, Zachary Mills

2011-01-01T23:59:59.000Z

411

Steam systems in industry: Energy use and energy efficiency improvement potentials  

E-Print Network (OSTI)

Alesson, T. 1995. "All Steam Traps Are Not Equal."Capturing Energy Savings with Steam Traps. ” Proc. 1997V. 1994. "Understand Steam Generator Performance." Chemical

Einstein, Dan; Worrell, Ernst; Khrushch, Marta

2001-01-01T23:59:59.000Z

412

Combined gas turbine and steam turbine power station  

SciTech Connect

In order to operate a gas turbine and steam turbine plant with a high temperature at the inlet to the gas turbine plant, the parts located in the hot-gas stream of the gas turbine being steam-cooled, and the cooling steam, thereby raised to a higher temperature, being fed to the steam turbine for further expansion, it is proposed that the waste heat from the gas turbine be led through a two-pressure waste heat boiler, and that the steam, generated in this boiler, be slightly superheated in a cooling-steam superheater, and fed to the hollow inlet vanes and to the rotor blades, which are likewise hollow, the steam, strongly superheated during this cooling process, then being admixed to the steam coming from the intermediate superheater, and being fed to the low-pressure section of the steam turbine.

Mukherjee, D.

1984-01-10T23:59:59.000Z

413

POWER PLANT USING A STEAM-COOLED NUCLEAR REACTOR  

SciTech Connect

A method of providing efficient and economic means for obtaining reheat from nuclear heat is described. A steamcooled steam-moderated reactor produces high-pressure, high-temperature steam. A multi-stage steam turbine partially expands the high-pressure steam, which is then withdrawn and reheated, and then further expanded for producing useful power. The saturated steam is superheated by leading it through tubular passages provided in the fuel assemblies of a nuclear reactor, leading the useful part of the superheated steam into a steam turbine in which it expands to a predetermined intermediate pressure, leading the steam at that reduced pressure from the turbine back into the reactor where it is reheated by flowing through other tubular passages in the fuel assemblies, and returning the reheated steam to the turbine for further expansion. (M.C.G.)

Nettel, F.; Nakanishi, T.

1963-10-29T23:59:59.000Z

414

Best Management Practice: Boiler/Steam Systems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Best Management Practice: Boiler/Steam Systems Best Management Practice: Boiler/Steam Systems Best Management Practice: Boiler/Steam Systems October 7, 2013 - 3:17pm Addthis Boilers and steam generators are commonly used in large heating systems, institutional kitchens, or in facilities where large amounts of process steam are used. This equipment consumes varying amounts of water depending on system size, the amount of steam used, and the amount of condensate returned. Operation and Maintenance Options To maintain water efficiency in operations and maintenance, Federal agencies should: Develop and implement a routine inspection and maintenance program to check steam traps and steam lines for leaks. Repair leaks and replace faulty steam traps as soon as possible. Develop and implement a boiler tuning program to be completed a minimum of

415

US DOE Industrial Steam BestPractices Software Tools  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOW RESTRICTED For internal DOW RESTRICTED For internal use only US DOE Industrial Steam BestPractices Software Tools Riyaz Papar, PE, CEM Hudson Technologies Company Phone: (281) 298 0975 Email: rpapar@hudsontech.com - Agenda * Introduction * Steam System BP Tools Suite - SSST - SSAT - 3EPlus * Q & A 1 Steam System Management Objective: Minimize Steam Use, Energy Losses And Most Importantly STEAM COST!! Steam Market Assessment Takeaways * Fuel savings estimates - individual projects - ranged from 0.6 percent to 5.2 percent * Estimated payback periods generally very attractive - Ranged from 2 to 34 months - Most less than 2 years * Potential steam savings in target industries - over 12 percent of fuel use 2 Promising Areas To Achieve Steam Energy and Cost Savings? Use Steam System Scoping Tool (SSST) For

416

Method and apparatus for powering engine with exhaust generated steam  

SciTech Connect

An apparatus for installation in an automobile to generate steam with heat from the exhaust of an engine is provided. The steam is generated at a sufficient pressure for entry into the combustion chambers of the engine to increase the power output of the engine. The apparatus includes a water storage unit and a steam generator for generating steam with the water from the unit through transfer of heat from combusted gases in the exhaust system. The steam travels through steam inlet manifolds for entry into the combustion chambers. The entry is controlled by a cylinder injection timing valve assembly timed to the operation of the engine to enter the steam during the power stroke. A steam throttling control valve assembly is provided to throttle the steam input to the combustion chambers. A throttle proportioning control unit proportions the carburetor throttle and steam throttle assembly to the operator throttle input to provide the greatest efficiency in engine operation. The throttle proportioning control unit operates in response to the steam temperature and pressure within the steam generator. The apparatus may be adapted for use on an engine design for solely air fuel combustion with the cylinder adapter. A throttle linkage interchange unit may be provided to initiate operation of steam input only upon reaching a minimum engine temperature. An intake manifold vacuum control valve may be provided for selectively entering exhaust gases into the intake manifold of the engine to compensate for the vacuum variation due to the steam input to the combustion chamber.

Gill, P.A.

1983-10-18T23:59:59.000Z

417

The Steam System Scoping Tool: Benchmarking Your Steam Operations Through Best Practices  

E-Print Network (OSTI)

The U.S. Department of Energy Office of Industrial Technology (DOE-OIT) BestPractice efforts aim to assist U.S. industry in adopting near-term energy-efficient technologies and practices through voluntary technical-assistance programs on improved system efficiency. The BestPractices Steam effort, a part of the DOE-OIT effort, has developed a new tool that steam energy managers and operations personnel can use to assess their steam operations and improve their steam energy usage -the Steam System Scoping Tool. This paper describes how the tool was developed, how the tool works, and the status of efforts to improve the tool in the future.

Wright, A.; Hahn, G.

2001-05-01T23:59:59.000Z

418

Optimizing Steam & Condensate System: A Case Study  

E-Print Network (OSTI)

Optimization of Steam & Condensate systems in any process plant results in substantial reduction of purchased energy cost. During periods of natural gas price hikes, this would benefit the plant in controlling their fuel budget significantly, irrespective of the plant's size. This paper highlights the efforts taken by the management of a medium sized specialty chemicals plant in North East Louisiana. This site spent over $19 million in 2007 ($13.7 million for natural gas & $5.6 million for electricity). The site generates steam for its process operation from 3 gas fired boilers at 525-psig pressure. The steam is consumed at 5 process areas; Acid, Basics, Crystals, Derivatives & Hydrogen plants. All of the process areas recover condensate inside their area, utilize it partially, and drain the rest into the sewer. Boiler Feed Water (BFW) is supplied from the water treatment plant located at the Boiler House. The optimization study was conducted at this site, between Jul - Sep 2008, to identify opportunities to reduce the energy cost and to improve the steam system's reliability. The study identified 5 energy cost optimization opportunities that would result in a total cost savings of $1,181,000 annually. The initial estimates indicated that all the 5 projects recommended by the study would have simple payback periods of less than 2 years. This case study is a good example and motivation for all engineers and managers who are responsible for maintaining the efficiency and reliability of small and medium sized steam systems.

Venkatesan, V. V.; Norris, C.

2011-01-01T23:59:59.000Z

419

IMPROVEMENTS IN STEAM GENERATING AND SUPERHEATING PLANT AND AN IMPROVED METHOD OF PRODUCING LOW PRESSURE SUPERHEATED STEAM  

SciTech Connect

A steam supply arrangement is described which generates high-pressure steam and superheats steam from a low-pressure source. Inus, in operations cteam at 350 to 600 psi from a nuciear reactor is superheated in a heat exehanger anu later in gas-heated equipment to 1100 F and passed to a stage of a pluralstage steam turbine. When the reactor ls shut downs steam generated in the steam generator section may be passed directly to the gas-fired superheater. (T.R.H.)

1959-02-18T23:59:59.000Z

420

Ultra supercritical turbines--steam oxidation  

SciTech Connect

Ultra supercritical (USC) power plants offer the promise of higher efficiencies and lower emissions, which are goals of the U.S. Department of Energy?s Advanced Power Systems Initiatives. Most current coal power plants in the U.S. operate at a maximum steam temperature of 538?C. However, new supercritical plants worldwide are being brought into service with steam temperatures of up to 620?C. Current Advanced Power Systems goals include coal generation at 60% efficiency, which would require steam temperatures of up to 760?C. This research examines the steamside oxidation of advanced alloys for use in USC systems, with emphasis placed on alloys for high- and intermediate-pressure turbine sections. Initial results of this research are presented.

Holcomb, Gordon R.; Covino, Bernard S., Jr.; Bullard, Sophie J.; Cramer, Stephen D.; Ziomek-Moroz, Margaret; Alman, David E.

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Subsurface steam sampling in Geysers wells  

DOE Green Energy (OSTI)

A new downhole sampling tool has been built for use in steam wells at The Geysers geothermal reservoir. The tool condenses specimens into an initially evacuated vessel that is opened down hole at the direction of an on-board computer. The tool makes a temperature log of the well as it is deployed, and the pressure and temperature of collected specimens are monitored for diagnostic purposes. Initial tests were encouraging, and the Department of Energy has funded an expanded effort that includes data gathering needed to develop a three-dimensional model of The Geysers geochemical environment. Collected data will be useful for understanding the origins of hydrogen chloride and non-condensable gases in the steam, as well as tracking the effect of injection on the composition of produced steam. Interested parties are invited to observe the work and to join the program.

Lysne, P. [Lysne (Peter), Albuquerque, NM (United States); Koenig, B. [Unocal Geothermal and Power Operations Group, Santa Rose, CA (United States); Hirtz, P. [Thermochem, Inc., Santa Rosa, CA (United States); Normann, R.; Henfling, J. [Sandia National Labs., Albuquerque, NM (United States)

1997-01-01T23:59:59.000Z

422

Integrated vacuum absorption steam cycle gas separation  

Science Conference Proceedings (OSTI)

Methods and systems for separating a targeted gas from a gas stream emitted from a power plant. The gas stream is brought into contact with an absorption solution to preferentially absorb the targeted gas to be separated from the gas stream so that an absorbed gas is present within the absorption solution. This provides a gas-rich solution, which is introduced into a stripper. Low pressure exhaust steam from a low pressure steam turbine of the power plant is injected into the stripper with the gas-rich solution. The absorbed gas from the gas-rich solution is stripped in the stripper using the injected low pressure steam to provide a gas stream containing the targeted gas. The stripper is at or near vacuum. Water vapor in a gas stream from the stripper is condensed in a condenser operating at a pressure lower than the stripper to concentrate the targeted gas. Condensed water is separated from the concentrated targeted gas.

Chen, Shiaguo (Champaign, IL); Lu, Yonggi (Urbana, IL); Rostam-Abadi, Massoud (Champaign, IL)

2011-11-22T23:59:59.000Z

423

Steam generation in compound parabolic concentrator collectors  

SciTech Connect

This report describes the advantages of generating steam directly in a nonimaging compound parabolic concentrator (CPC) collector rather than using a heat-transfer fluid and a secondary heat exchanger. The predicted performance advantages from generating steam directly in CPC collectors are significant, and that performance has ben verified using a collector built and tested at Argonne National Laboratory. The collector and the method used to test its operation in a steam-generating mode are described. Test results are included for a 6.4-m/sup 2/ array of evacuated tube collectors with an advanced absorber coating, silver reflectors, and tubes oriented in a north-south configuration. Also described are the test methods and results for indoor testing for heat loss by the collectors and outdoor testing of their instantaneous optical efficiency.

Allen, J.W.; Schertz, W.W.; Wantroba, A.S.

1985-08-01T23:59:59.000Z

424

Drying of pulverized material with heated condensible vapor  

DOE Patents (OSTI)

Apparatus for drying pulverized material utilizes a high enthalpy condensable vapor such as steam for removing moisture from the individual particles of the pulverized material. The initially wet particulate material is tangentially delivered by a carrier vapor flow to an upper portion of a generally vertical cylindrical separation drum. The lateral wall of the separation drum is provided with a plurality of flow guides for directing the vapor tangentially therein in the direction of particulate material flow. Positioned concentrically within the separation drum and along the longitudinal axis thereof is a water-cooled condensation cylinder which is provided with a plurality of collection plates, or fines, on the outer lateral surface thereof. The cooled collection fines are aligned counter to the flow of the pulverized material and high enthalpy vapor mixture to maximize water vapor condensation thereon. The condensed liquid which includes moisture removed from the pulverized materials then flows downward along the outer surface of the coolant cylinder and is collected and removed. The particles travel in a shallow helix due to respective centrifugal and vertical acceleration forces applied thereto. The individual particles of the pulverized material are directed outwardly by the vortex flow where they contact the inner cylindrical surface of the separation drum and are then deposited at the bottom thereof for easy collection and removal. The pulverized material drying apparatus is particularly adapted for drying coal fines and facilitates the recovery of the pulverized coal. 2 figs.

Carlson, L.W.

1984-08-16T23:59:59.000Z

425

Utilization of geothermal heat in tropical fruit-drying process  

DOE Green Energy (OSTI)

The power plant utilizes only the steam portion of the HGP-A well production. There are approximately 50,000 pounds per hour of 360/sup 0/F water produced (approximately 10 million Btu per hour) and the water is currently not used and is considered a waste. This tremendous resource could very well be used in applications such as food processing, food dehydration and other industrial processing that requires low-grade heat. One of the applications is examined, namely the drying of tropical fruits particularly the papaya. The papaya was chosen for the obvious reason that it is the biggest crop of all fruits produced on the Big Island. A conceptual design of a pilot plant facility capable of processing 1000 pounds of raw papaya per day is included. This facility is designed to provide a geothermally heated dryer to dehydrate papayas or other tropical fruits available on an experimental basis to obtain data such as drying time, optimum drying temperature, etc.

Chen, B.H.; Lopez, L.P.; King, R.; Fujii, J.; Tanaka, M.

1982-10-01T23:59:59.000Z

426

Description and cost analysis of a deluge dry/wet cooling system.  

SciTech Connect

The use of combined dry/wet cooling systems for large base-load power plants offers the potential for significant water savings as compared to evaporatively cooled power plants and significant cost savings in comparison to dry cooled power plants. The results of a detailed engineering and cost study of one type of dry/wet cooling system are described. In the ''deluge'' dry/wet cooling method, a finned-tube heat exchanger is designed to operate in the dry mode up to a given ambient temperature. To avoid the degradation of performance for higher ambient temperatures, water (the delugeate) is distributed over a portion of the heat exchanger surface to enhance the cooling process by evaporation. The deluge system used in this study is termed the HOETERV system. The HOETERV deluge system uses a horizontal-tube, vertical-plate-finned heat exchanger. The delugeate is distributed at the top of the heat exchanger and is allowed to fall by gravity in a thin film on the face of the plate fin. Ammonia is used as the indirect heat transfer medium between the turbine exhaust steam and the ambient air. Steam is condensed by boiling ammonia in a condenser/reboiler. The ammonia is condensed in the heat exchanger by inducing airflow over the plate fins. Various design parameters of the cooling system have been studied to evaluate their impact on the optimum cooling system design and the power-plant/utility-system interface. Annual water availability was the most significant design parameter. Others included site meteorology, heat exchanger configuration and air flow, number and size of towers, fan system design, and turbine operation. It was concluded from this study that the HOETERV deluge system of dry/wet cooling, using ammonia as an intermediate heat transfer medium, offers the potential for significant cost savings compared with all-dry cooling, while achieving substantially reduced water consumption as compared to an evaporatively cooled power plant. (LCL)

Wiles, L.E.; Bamberger, J.A.; Braun, D.J.; Braun, D.J.; Faletti, D.W.; Willingham, C.E.

1978-06-01T23:59:59.000Z

427

Textile Drying Via Wood Gasification  

E-Print Network (OSTI)

This project was carried out to investigate the possibility of using wood gas as a direct replacement for natural gas in textile drying. The Georgia Tech updraft gasifier was used for the experimental program. During preliminary tests, the 1 million Btu/hr pilot plant produced clean burning gas which appeared viable for drying textiles. The gasifier was coupled to a modified textile drying oven and a series of tests were carried out to assess product degradation of white, colored, and chemically treated fabrics.

McGowan, T. F.; Jape, A. D.

1983-01-01T23:59:59.000Z

428

Dry Ice vs. Pipette Experiment Description  

E-Print Network (OSTI)

Dry Ice vs. Pipette Experiment Description Dry ice (solid) is put into the bulb of a pipette, plastic pipette 1 ice cube sized piece of dry ice Butter knife (or some object to break dry ice) Gloves (surgical gloves will not work, they must protect hands from dry ice) Safety glasses for demonstrator

429

Turbine Steam Path Damage: Theory and Practice  

Science Conference Proceedings (OSTI)

Historically, most treatises about steam turbines have concentrated on thermo-dynamics or design. In contrast, the primary focus of this book is on the problems that occur in the turbine steam path. Some of these problems have been long known to the industry, starting as early as A. Stodola's work at the turn of the century in which mechanisms such as solid particle erosion, corrosion and liquid droplet damage were recognized. What we have tried to do here is to provide, in a single, comprehensive refere...

1999-08-18T23:59:59.000Z

430

Spent fuel drying system test results (second dry-run)  

DOE Green Energy (OSTI)

The water-filled K-Basins in the Hanford 100 Area have been used to store N-Reactor spent nuclear fuel (SNF) since the 1970s. Because some leaks have been detected in the basins and some of the fuel is breached due to handling damage and corrosion, efforts are underway to remove the fuel elements from wet storage. An Integrated Process Strategy (IPS) has been developed to package, dry, transport, and store these metallic uranium fuel elements in an interim storage facility on the Hanford Site (WHC 1995). Information required to support the development of the drying processes, and the required safety analyses, is being obtained from characterization tests conducted on fuel elements removed from the K-Basins. A series of whole element drying tests (reported in separate documents, see Section 7.0) have been conducted by Pacific Northwest National Laboratory (PNNL) on several intact and damaged fuel elements recovered from both the K-East and K-West Basins. This report documents the results of the second dry-run test, which was conducted without a fuel element. With the concurrence of project management, the test protocol for this run, and subsequent drying test runs, was modified. These modifications were made to allow for improved data correlation with drying procedures proposed under the IPS. Details of these modifications are discussed in Section 3.0.

Klinger, G.S.; Oliver, B.M.; Abrefah, J.; Marschman, S.C.; MacFarlan, P.J.; Ritter, G.A.

1998-07-01T23:59:59.000Z

431

Lowest Pressure Steam Saves More BTU's Than You Think  

E-Print Network (OSTI)

Steam is the most common and economical way of transferring heat from one location to another. But most steam systems use the header pressure steam to do the job. The savings are substantially more than just the latent heat differences between the high and low steam pressures. The discussion below shows how the savings in using low pressure steam can be above 25%! The key to the savings is not in the heat exchanger equipment or the steam trap, but is back at the powerhouse - the sensible heat requirement of the boiler feed water. Chart III shows potential steam energy savings and will be useful in estimating the steam energy savings of high pressure processes.

Vallery, S. J.

1985-05-01T23:59:59.000Z

432

Use a Vent Condenser to Recover Flash Steam Energy (Revised)  

Science Conference Proceedings (OSTI)

This revised ITP tip sheet on vent condenser to recover flash steam energy provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2006-05-01T23:59:59.000Z

433

The essence of steam technology and its link to distillation  

E-Print Network (OSTI)

The essence of steam technology, as Simon Schaffer explains in Faraday’s laboratory, is to understand the behaviour of fire, water and steam. The role of glass in manipulating these is absolutely fundamental, as is the role of distilling....

Dugan, David

2004-08-17T23:59:59.000Z

434

Cheng Cycle Brings Flexibility to Steam Plant  

E-Print Network (OSTI)

In 1983 Frito-Lay embarked on building a new 160,000 sq. ft. manufacturing facility in Kern County California. Based upon an estimated steam load between 5,000 and 50,000 lb/hr and an electrical load of approximately 1500 KW, the Engineering Department examined several energy optimization systems for this site. It was determined that a modified gas turbine cogeneration system was the best overall option. This system is unique in that it injects superheated steam from the waste heat boiler back into the gas turbine. When steam is injected into the turbine combustor, electrical output increases due to the increased mass flow and specific heat of the steam/air mixture. Electrical output ranges from 3.5 KW without injection to a theoretical 6.0 KW at maximum injection. Despite the volatility of nuclear power in California, project risk was low because the implementation of nuclear power would increase retail rates whereas the avoidance of nuclear power would increase avoided costs (buyback rates). When Frito-Lay decided, in 1983, to build a new snack food plant in Kern County, Calif., its main concern was to minimize the plant's total energy costs. The company therefore evaluated the various cogeneration options available and, for each option, conducted an energy-cost analysis. However, plant performance was not to be sacrificed in order to reduce the overall energy costs. After technical and economic analysis had been completed, Frito-Lay chose a cogeneration system using the Cheng Cycle---a gas-turbine system using steam injection that allows for efficient thermal tracking and simultaneous electrical generation. The company began construction of the Kern County plant to produce corn, tortilla, and potato chips in October 1984. Preliminary operation began in April 1986. The plant encompasses 160,000 ft, and is located just outside the city of Bakersfield. Steam is used for space heating as well as process applications. Total steam demand is expected to vary between 5000 and 55,000 lb/hr, depending on production and seasonal variations. The electrical usage of the plant is anticipated to fall between 1000 and 2500 kW, again depending on plant operations. Current utility energy costs are on the order of 50¢/therm for natural gas and 9¢/kWh for electricity. Cogeneration technology involves the simultaneous production of thermal and electrical energy. In Frito-Lay's case, the cogeneration system supplies steam for plant process needs and generates electricity for plant consumption and sale to the local utility. The modified gas turbine used in the plant is a Cheng Cycle Series Seven, Figure 1. It is a product of International Power Technology (IPT) of Palo Alto, Calif., which has patented the steam injection and control systems. The system is unique in that it injects superheated steam from the waste heat boiler back into the gas turbine. This steam injection process increases the electrical output of the turbine and improves cycle performance compared to traditional gas turbine systems.

Keller, D. C.; Bynum, D.; Kosla, L.

1987-09-01T23:59:59.000Z

435

Closed cycle steam turbine system with liquid vortex pump  

SciTech Connect

A closed cycle steam generating system is described comprising a steam boiler, and a steam turbine includes a vacuum pump of the liquid vortex type for condensing the exhaust steam from the turbine, a feedwater pump being employed for returning the condensate to the boiler. The tank of the vortex pump is maintained filled with water and the pressure in the tank is regulated automatically to maintain a predetermined value thereof.

Brown, K.D.

1976-08-10T23:59:59.000Z

436

Productivity Improvement for Fossil Steam Power Plants, 2008  

Science Conference Proceedings (OSTI)

EPRI's Productivity Improvement Handbook for Fossil Steam Plants (1006315), now in its third edition, has included many descriptions of advanced techniques and products successfully applied and tested. Many of these have been described in the other EPRI publications: Productivity Improvement for Fossil Steam Power Plants 2005: 100 Hundred Case Studies (1012098), Productivity Improvement for Fossil Steam Power Plants, 2006, (1014598), and Productivity Improvement for Fossil Steam Power Plants, 2007 (10154...

2008-12-24T23:59:59.000Z

437

Materials for Ultra-Supercritical Steam Power Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

for Advanced Ultra-Supercritical for Advanced Ultra-Supercritical Steam Power Plants Background The first ultra-supercritical (USC) steam plants in the U.S. were designed, constructed, and operated in the late 1950s. The higher operating temperatures and pressures in USC plants were designed to increase the efficiency of steam plants. However, materials performance problems forced the reduction of steam temperatures in these plants, and discouraged further developmental efforts on low heat-rate units.

438

Productivity Improvement for Fossil Steam Power Plants, 2010  

Science Conference Proceedings (OSTI)

The Productivity Improvement Handbook for Fossil Steam Plants (1006315), now in its third edition, has included many descriptions of advanced techniques and products, successfully applied and tested. Many of these have been described in the 2005 publication Productivity Improvement for Fossil Steam Plants 2005: 100 Hundred Case Studies (1012098), Productivity Improvement for Fosiil Steam Power Plants 2006, (101459), Productivity Improvement for Fossil Steam Power Plants 2007 (1015445), Productivity Impro...

2011-01-31T23:59:59.000Z

439

NEWTON: Preventing Tire Dry Rot  

NLE Websites -- All DOE Office Websites (Extended Search)

Preventing Tire Dry Rot Preventing Tire Dry Rot Name: Millard Status: student Grade: 9-12 Location: MD Country: USA Date: Spring 2013 Question: My dad has a classic car, and because it gets driven very little each year, the tires dry rot before he can get much tread wear on them. What could be used to protect the tires from dry rot and cracking? Replies: Hi Millard, Thanks for the question. I would recommend keeping the car on blocks so that there is no weight on the tires. Additionally, I would recommend that no electrical equipment (motors, switches, and other things that spark) be used around the car. The sparks generate ozone and ozone can cause rubber items such as tires, belts, and hoses to crack. I hope this helps. Please let me know if you have more questions. Thanks Jeff Grell

440

DRI Companies | Open Energy Information  

Open Energy Info (EERE)

DRI Companies DRI Companies Jump to: navigation, search Name DRI Companies Place Irvine, California Zip 92614 Sector Solar Product US-based residential and commercial installer of turnkey solar systems, through subsidiary iDRI Energy. Coordinates 41.837752°, -79.268594° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.837752,"lon":-79.268594,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Abrasives for Dry Blast Cleaning  

Science Conference Proceedings (OSTI)

...The materials used in dry abrasive blast cleaning can be categorized as metallic grit, metallic shot, sand, glass, and miscellaneous. Hardness, density, size, and shape are important considerations in choosing an abrasive for a specific

442

Manganese and Ceria Sorbents for High Temperature Sulfur Removal from Biomass-Derived Syngas -- The Impact of Steam on Capacity and Sorption Mode  

Science Conference Proceedings (OSTI)

Syngas derived from biomass and coal gasification for fuel synthesis or electricity generation contains sulfur species that are detrimental to downstream catalysts or turbine operation. Sulfur removal in high temperature, high steam conditions has been known to be challenging, but experimental reports on methods to tackle the problem are not often reported. We have developed sorbents that can remove hydrogen sulfide from syngas at high temperature (700 C), both in dry and high steam conditions. The syngas composition chosen for our experiments is derived from statistical analysis of the gasification products of wood under a large variety of conditions. The two sorbents, Cu-ceria and manganese-based, were tested in a variety of conditions. In syngas containing steam, the capacity of the sorbents is much lower, and the impact of the sorbent in lowering H{sub 2}S levels is only evident in low space velocities. Spectroscopic characterization and thermodynamic consideration of the experimental results suggest that in syngas containing 45% steam, the removal of H{sub 2}S is primarily via surface chemisorptions. For the Cu-ceria sorbent, analysis of the amount of H{sub 2}S retained by the sorbent in dry syngas suggests both copper and ceria play a role in H{sub 2}S removal. For the manganese-based sorbent, in dry conditions, there is a solid state transformation of the sorbent, primarily into the sulfide form.

Cheah, S.; Parent, Y. O.; Jablonski, W. S.; Vinzant, T.; Olstad, J. L.

2012-07-01T23:59:59.000Z

443

Failure probabilities of steam generator tubes. Annual report  

SciTech Connect

BNL's efforts focused on the following specific items; the probabilities of failure for perfect steam generator tubes, the probabilities of failure for steam generator tubes containing long axisymmetrically thinned sections, and the probabilities of failure for steam generator tubes containing finite length (relatively short) axisymmetric wastages. (auth)

Reich, M.

1975-08-01T23:59:59.000Z

444

October 15, 2001 PRE-INSULATED UNDERGROUND PIPE FOR STEAM  

E-Print Network (OSTI)

SERVICE PART 1 ­ GENERAL 1.01 SUMMARY Underground steam and condensate distribution systems includingOctober 15, 2001 02558-1 PRE-INSULATED UNDERGROUND PIPE FOR STEAM AND CONDENSATE SERVICE CONSTRUCTION STANDARD SPECIFICATION SECTION 02558 PRE-INSULATED UNDERGROUND PIPE FOR STEAM AND CONDENSATE

445

Efficiency of Steam and Hot Water Heat Distribution Systems  

E-Print Network (OSTI)

Efficiency of Steam and Hot Water Heat Distribution Systems Gary Phetteplace September 1995- tion medium (steam or hot water) and temperature for heat distribution systems. The report discusses the efficiency of both steam and hot water heat distribution systems in more detail. The results of several field

446

An Object-Oriented Algebraic Steam-Boiler Control Specification  

E-Print Network (OSTI)

An Object-Oriented Algebraic Steam-Boiler Control Specification Peter Csaba ()lveczky, Poland Abstract. In this paper an object-oriented algebraic solution of the steam-boiler specification Introduction The steam-boiler control specification problem has been proposed as a challenge for different

Ã?lveczky, Peter Csaba

447

Project Recap Humanitarian Engineering Biodiesel Boiler System for Steam Generator  

E-Print Network (OSTI)

Project Recap Humanitarian Engineering ­ Biodiesel Boiler System for Steam Generator Currently 70 biodiesel boiler system to drive a steam engine generator. This system is to provide electricity the customer needs, a boiler fueled by biodiesel and outputting to a steam engine was decided upon. The system

Demirel, Melik C.

448

Steam boiler control speci cation problem: A TLA solution  

E-Print Network (OSTI)

Steam boiler control speci cation problem: A TLA solution Frank Le ke and Stephan Merz Institut fur of the state of the steam boiler, detect failures, and model message transmission. We give a more detailed between the physi- cal state of the steam boiler and the model maintained by the controller and discuss

Cengarle, María Victoria

449

Steam boiler control specification problem: A TLA solution  

E-Print Network (OSTI)

Steam boiler control specification problem: A TLA solution Frank Le�ke and Stephan Merz Institut f of the state of the steam boiler, detect failures, and model message transmission. We give a more detailed between the physi­ cal state of the steam boiler and the model maintained by the controller and discuss

Merz, Stephan

450

An Object-Oriented Algebraic Steam-Boiler Control Specification  

E-Print Network (OSTI)

An Object-Oriented Algebraic Steam-Boiler Control Specification.In this paper an object-oriented algebraic solution of the steam-boiler specification problem is presented computations cannot happen. 1 Introduction The steam-boiler control specification problem has been

Ã?lveczky, Peter Csaba

451

EXPERIMENTAL DETERMINATION OF STEAM WATER RELATIVE PERMEABILITY RELATIONS  

E-Print Network (OSTI)

EXPERIMENTAL DETERMINATION OF STEAM WATER RELATIVE PERMEABILITY RELATIONS A REPORT SUBMITTED;Abstract A set of relative permeability relations for simultaneous ow of steam and water in porous media with saturation and pressure measurements. These relations show that the relative permeability for steam phase

Stanford University

452

EXPERIMENTAL MEASUREMENT OF STEAM-WATER RELATIVE PERMEABILITY  

E-Print Network (OSTI)

EXPERIMENTAL MEASUREMENT OF STEAM-WATER RELATIVE PERMEABILITY A REPORT SUBMITTED TO THE DEPARTMENT calculations. X-ray computer tomography (CT) aided by measuring in-situ steam saturation more directly. The measured steam-water relative permeability curves assume a shape similar to those obtained by Corey (1954

Stanford University

453

COMPUTER SIMULATION OF SINGLE-WELL STEAM ASSISTED GRAVITY DRAINAGE  

E-Print Network (OSTI)

COMPUTER SIMULATION OF SINGLE-WELL STEAM ASSISTED GRAVITY DRAINAGE (SW-SAGD) TR 119 By Keith T of Sensitivity Analysis Cases 32 #12;v List of Figures Figure 1: Steam Assisted Gravity Drainage Concept: Recovery Factor vs. Time for All Cases (10 Years Production) 13 Figure 8: Cumulative Steam-Oil Ratio vs

454

Replace Pressure-Reducing Valves with Backpressure Turbogenerators (International Fact Sheet), Energy Tips-Steam, Steam Tip Sheet #20c  

SciTech Connect

This English/Chinese ITP steam tip sheet on replacing pressure-reducing valves provides how-to advice for improving industrial steam systems using low-cost, proven practices and technologies.

Not Available

2010-10-01T23:59:59.000Z

455

Steam Generator Management Program: Pressurized Water Reactor Steam Generator Examination Guidelines: Revision 7  

Science Conference Proceedings (OSTI)

This report provides requirements for examination plans and processes that are necessary to meet the performance criteria set forth in the Nuclear Energy Institute (NEI) 97-06, Steam Generator Program.

2007-10-10T23:59:59.000Z

456

Channels and sources used to gather equine-related information by college-age horse owners and enthusiasts  

E-Print Network (OSTI)

This thesis identifies the equine-related topics that are important to Texas college-age horse owners and enthusiasts and the channels/sources they use to get equine-related information. Little research has focused on this group to determine their information needs. Therefore, two focus groups were conducted in 2008 in Texas with college-age horse owners and enthusiasts to conduct a needs assessment. Participants were separated into competitive and recreational groups depending on their level of participation in the industry. They were asked what topics they consider important and what channels/sources they use to gain desired information. Training was the most mentioned topic overall, and the most mentioned by recreational participants. Alternative medical treatments was the most mentioned topic by competitive participants. Competitive participants reported a smaller number of topics as important, indicating that they have specialized information needs. Recreational participants emphasized broader, less specialized topics. Participants showed an interest in relevant and controversial topics affecting the equine industry. Participants also used a combination of channels/sources and competitive and recreational participants often placed importance on different channels/sources. Face-to-face communication was important to both groups. Magazines were important to competitive participants, while the Internet was important to recreational participants. Competitive participants doubted the trustworthiness of sources available through the Internet, but wanted more reliable sources to be made available in the future. Participants preferred to get information from industry specialist sources, such as trainers, veterinarians, other owners and enthusiasts, breed associations, and equine magazines. Participants’ perceptions of trustworthiness were affected by the source’s ability to demonstrate equine-specific knowledge and the source’s reputation and success among equine industry members. The results suggests that the influence of the Internet has altered the traditional models of communication in which source selection determines channel use. In this study, the participants’ Internet channel selection often determined their source use. The results also suggests that communicators wanting to reach this audience should target specific topics to competitive and recreational audiences, use a multi-channel approach, establish trustworthiness, and explore the changing role of the Internet in agricultural communication.

Sullivan, Erin Alene

2008-12-01T23:59:59.000Z

457

Analytical steam injection model for layered systems  

SciTech Connect

Screening, evaluation and optimization of the steam flooding process in homogeneous reservoirs can be performed by using simple analytical predictive models. In the absence of any analytical model for layered reservoirs, at present, only numerical simulators can be used. And these are expensive. In this study, an analytical model has been developed considering two isolated layers of differing permeabilities. The principle of equal flow potential is applied across the two layers. Gajdica`s (1990) single layer linear steam drive model is extended for the layered system. The formulation accounts for variation of heat loss area in the higher permeability layer, and the development of a hot liquid zone in the lower permeability layer. These calculations also account for effects of viscosity, density, fractional flow curves and pressure drops in the hot liquid zone. Steam injection rate variations in the layers are represented by time weighted average rates. For steam zone calculations, Yortsos and Gavalas`s (1981) upper bound method is used with a correction factor. The results of the model are compared with a numerical simulator. Comparable oil and water flow rates, and breakthrough times were achieved for 100 cp oil. Results with 10 cp and 1000 cp oils indicate the need to improve the formulation to properly handle differing oil viscosities.

Abdual-Razzaq; Brigham, W.E.; Castanier, L.M.

1993-08-01T23:59:59.000Z

458

Method of removing cesium from steam  

SciTech Connect

Method for removal of radioactive cesium from a hot vapor, such as high temperature steam, including the steps of passing input hot vapor containing radioactive cesium into a bed of silicate glass particles and chemically incorporating radioactive cesium in the silicate glass particles at a temperature of at least about 700.degree. F.

Carson, Jr., Neill J. (Clarendon Hills, IL); Noland, Robert A. (Oak Park, IL); Ruther, Westly E. (Skokie, IL)

1991-01-01T23:59:59.000Z

459

Workshop Proceedings: Pitting in Steam Generator Tubing  

Science Conference Proceedings (OSTI)

A two-day workshop focused on the probable causes of steam generator pitting at two nuclear plants and on whether pitting is a low-temperature or a high-temperature phenomenon. Participants also heard descriptions of various pit-resistant metals that are suitable for tube sleeving.

1984-10-01T23:59:59.000Z

460

Natural gas-assisted steam electrolyzer  

DOE Patents (OSTI)

An efficient method of producing hydrogen by high temperature steam electrolysis that will lower the electricity consumption to an estimated 65 percent lower than has been achievable with previous steam electrolyzer systems. This is accomplished with a natural gas-assisted steam electrolyzer, which significantly reduces the electricity consumption. Since this natural gas-assisted steam electrolyzer replaces one unit of electrical energy by one unit of energy content in natural gas at one-quarter the cost, the hydrogen production cost will be significantly reduced. Also, it is possible to vary the ratio between the electricity and the natural gas supplied to the system in response to fluctuations in relative prices for these two energy sources. In one approach an appropriate catalyst on the anode side of the electrolyzer will promote the partial oxidation of natural gas to CO and hydrogen, called Syn-Gas, and the CO can also be shifted to CO.sub.2 to give additional hydrogen. In another approach the natural gas is used in the anode side of the electrolyzer to burn out the oxygen resulting from electrolysis, thus reducing or eliminating the potential difference across the electrolyzer membrane.

Pham, Ai-Quoc (San Jose, CA); Wallman, P. Henrik (Berkeley, CA); Glass, Robert S. (Livermore, CA)

2000-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dry steam owner" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Fuel cell integrated with steam reformer  

DOE Patents (OSTI)

A H.sub.2 -air fuel cell integrated with a steam reformer is disclosed wherein a superheated water/methanol mixture is fed to a catalytic reformer to provide a continuous supply of hydrogen to the fuel cell, the gases exhausted from the anode of the fuel cell providing the thermal energy, via combustion, for superheating the water/methanol mixture.

Beshty, Bahjat S. (Lower Makefield, PA); Whelan, James A. (Bricktown, NJ)

1987-01-01T23:59:59.000Z

462

Gas turbine row #1 steam cooled vane  

DOE Patents (OSTI)

A design for a vane segment having a closed-loop steam cooling system is provided. The vane segment comprises an outer shroud, an inner shroud and an airfoil, each component having a target surface on the inside surface of its walls. A plurality of rectangular waffle structures are provided on the target surface to enhance heat transfer between each component and cooling steam. Channel systems are provided in the shrouds to improve the flow of steam through the shrouds. Insert legs located in cavities in the airfoil are also provided. Each insert leg comprises outer channels located on a perimeter of the leg, each outer channel having an outer wall and impingement holes on the outer wall for producing impingement jets of cooling steam to contact the airfoil's target surface. Each insert leg further comprises a plurality of substantially rectangular-shaped ribs located on the outer wall and a plurality of openings located between outer channels of the leg to minimize cross flow degradation.

Cunha, Frank J. (Longwood, FL)

2000-01-01T23:59:59.000Z

463

Guidelines for Maintaining Steam Turbine Lubrication Systems  

Science Conference Proceedings (OSTI)

Failures of steam turbine bearings and rotors cost the utility industry an estimated $150 million a year. A third of these failures involve contaminated lubricants or malfunctioning lubricant supply system components. This report, outlining a comprehensive surveillance program, presents guidelines for maintaining major elements in the turbine lubrication system.

1986-07-01T23:59:59.000Z

464

Low chemical concentrating steam generating cycle  

DOE Patents (OSTI)

A steam cycle for a nuclear power plant having two optional modes of operation. A once-through mode of operation uses direct feed of coolant water to an evaporator avoiding excessive chemical concentration buildup. A recirculation mode of operation uses a recirculation loop to direct a portion of flow from the evaporator back through the evaporator to effectively increase evaporator flow.

Mangus, James D. (Greensburg, PA)

1983-01-01T23:59:59.000Z

465

A SIMULATION OF THE EGCR STEAM GENERATOR  

SciTech Connect

An analog model of the EGCR steam generator was developed and operated on the ORNL analog computer as part of a program to simulate the operation and control of the EGCR reactor plant. Equilibrium operation and the transient response of the steam generator unit to system perturbations were studied. A simultaneous solution of the basic heat transfer equations representing the performance of the unit was obtained. The model was operated initially at steady- state conditions, and then perturbations were made to gas flow, gas inlet temperature, and steam throttle valve position. The response characteristics of the model during the transients were recorded. The steam generator gas outlet temperature showed a marked degree of insensitivity to changes in gas inlet temperature. The effect of gas flow changes on gas exit temperature was slightly more pronounced. The transient behavio-r of the unit was reasonable, and the model developed indicated satisfactory operation within the design range of 20 to l00% of full power. (auth)

Yarosh, M.M.; Ball, S.J.

1961-10-01T23:59:59.000Z

466

Proceedings: Steam Turbine Stress Corrosion Workshop  

Science Conference Proceedings (OSTI)

A recent survey of utilities commissioned by EPRI indicated that cracking of steam turbine disk rims by stress corrosion was a pervasive problem in both fossil and nuclear power plants. There is a clear need to document industry experience in this area so that guidelines can be provided to utilities on managing the problem.

1997-11-03T23:59:59.000Z

467

Task 1—Steam Oxidation (NETL-US)  

SciTech Connect

The proposed steam in let temperature in the Advanced Ultra Supercritical (A·USC) steam turbine is high enough (760°C) Ihat traditional turbine casing and valve body materials such as ferr;tic/manensitic steels will not suffice due to temperature lim itations of this class of materials. Cast versions of three traditionally wrought Ni-based superalloys (Haynes 263. Haynes 282, and Nimonic 105) were evaluated for use as casing or valve components for the next generation of industrial steam turbines. The full size castings are substantia l: 2-5,000 kg each half and on the order of 100 nun thick. Experimental castings were quite a bit smaller, but section size was retained and cooling rate controlled to produce equi valem microslruclUre •. A multi_step homogenization heat treatment was d~ve loped to better disperse the al loy constituents. These castings were subsequently evaluated by characterizing their microstructure as well as their steam oxidation resistance (al 760 and 800 "C).

G. R. Holcomb

2010-05-01T23:59:59.000Z

468

Compressor & Steam Turbine Efficiency Improvements & Revamping Opportunities  

E-Print Network (OSTI)

Fossil fuels remain the dominant source for primary energy production worldwide. In relation to this trend, energy consumption in turbomachinery has been increasing due to the scale up of both the machinery itself as well as the processing plants in which they operate. This energy growth requires high efficiency improvements for machine design and operation to minimize life cycle cost. This paper will focus on the mechanical drive steam turbines which power the main process equipment in the heart of the plant and introduce the history of efficiency improvements for compressors and steam turbines in the Petrochemical Industry. Since heat balance configurations affect the plant's steam consumption, the authors will explain several cases of heat balance configurations and applications / selections of steam turbines. According to the change in output demand, in some cases the original plants are modified by increasing capacity and consequently the turbines and compressors are revamped internally or replaced totally. The authors will introduce several case studies on revamping to increase efficiency and reliability as per the following cases: a) Replacement of High Pressure Section Internals b) Replacement of Low Pressure Section Internals c) Replacement of All Internals d) Internals and Casing Replacement e) Efficiency Recovery Technique Modification Finally, life cycle cost (LCC) evaluation and sensitivity due to turbomachinery performance are explained as a case study of a mega ethylene plant.

Hata, S.; Horiba, J.; Sicker, M.

2011-01-01T23:59:59.000Z

469

Steam Generator Management Program: Proceedings of the 25th Steam Generator NDE Workshop  

Science Conference Proceedings (OSTI)

This year8217s workshop took place in Marco Island, Florida, on July 24 26, 2006, and included one full-day and two half-days of presentations. Attendees included representatives from domestic and international nuclear utilities, nuclear steam supply system (NSSS) vendors, nondestructive evaluation (NDE) service and equipment organizations, research laboratories, and regulatory bodies. This annual workshop serves as a forum for NDE specialists to gather and discuss current steam generator NDE issues and ...

2006-11-21T23:59:59.000Z

470

Proceedings: Steam Generator Management Program 2012 Steam Generator Secondary Side Management Conference  

Science Conference Proceedings (OSTI)

This report contains the work presented at the EPRI Steam Generator Management Program (SGMP) 2012 Steam Generator Secondary Side Management Conference. Over eighty attendees, representing both domestic and international utilities, vendors, and academia, participated in the conference. It included twenty-one papers on current issues, research and utility experiences involving corrosion product generation and transport, deposit control and mitigation, deposit consolidation and removal, and short- and ...

2012-12-21T23:59:59.000Z

471

Steam Generator Management Program: PWR Steam Generator Top-of-Tubesheet Denting  

Science Conference Proceedings (OSTI)

Denting of steam generator tubing is the reduction in tube diameter due to the forces exerted by corrosion products on the outer diameter surfaces. This deformation can increase the risk of stress corrosion cracking due to the high stresses, strains, and cold work developed in the tube. Historically, denting at carbon steel tube support plate locations was a significant factor necessitating the early replacement of several steam generators. Currently, denting and stress corrosion cracking are being exper...

2012-06-06T23:59:59.000Z

472

Steam Generator Management Program: Effect of Eddy Current Noise on Sizing Steam Generator Tube Degradation  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute’s (EPRI’s) Steam Generator Management Program (SGMP) has developed procedures and tools to assist utility engineers in understanding the probability of detection (POD) in steam generator eddy current data in the presence of noise. Under some circumstances, eddy current noise can mask flaws that should be detected and assessed for tube integrity. This project focused on the ability to accurately size crack-like indications in the presence of eddy ...

2013-11-11T23:59:59.000Z

473

Steam Generator Management Program: Steam Generator Foreign Object Task Force Review Material  

Science Conference Proceedings (OSTI)

Foreign objects entering a steam generator (SG) can result in significant damage to tubing. Foreign objects have caused utilities to plug tubes, extend inspections, and, in some cases, shut down due to primary-to-secondary leakage.BackgroundTo gain a better understanding of the significance of the foreign object problem relative to SGs, the Electric Power Research Institute (EPRI) Steam Generator Management Program (SGMP) assembled a task force in 2005 made ...

2013-08-09T23:59:59.000Z

474

Steam Generator Management Program: Evaluation of Steam Generator Eddy Current Analysis Algorithms  

Science Conference Proceedings (OSTI)

As part of the U.S. Nuclear Regulatory Commissions (NRCs) International Steam Generator Tube Integrity Program, Argonne National Laboratory (ANL) evaluated algorithms for computer-aided analysis of rotating probe eddy current data. The algorithms were designed for both flaw detection and flaw sizing. Rotating probe data collected on the flawed tubes in the NRCs steam generator (SG) mockup were used to document performance of the algorithms for both detection and sizing. In the NRC program, the results of...

2011-06-30T23:59:59.000Z

475

Consider Steam Turbine Drives for Rotating Equipment: Office of Industrial Technologies (OIT) Steam Tip Fact Sheet No.21  

SciTech Connect

Steam turbines are well suited as prime movers for driving boiler feedwater pumps, forced or induced-draft fans, blowers, air compressors, and other rotating equipment. This service generally calls for a backpressure non-condensing steam turbine. The low-pressure steam turbine exhaust is available for feedwater heating, preheating of deaerator makeup water, and/or process requirements.

2002-01-01T23:59:59.000Z

476

Advanced high performance steam systems for industrial cogeneration: Final report  

SciTech Connect

Advanced steam conditions of 1500/sup 0/F and 1500 psig have been shown to offer a major positive economic impact and a dramatic improvement in cogeneration system performance. In a back pressure steam turbine system, electricity production increases by 80%, and the return on investment improves by 60%. For a 35% extraction turbine, the electricity production increases 28% and the return increases by 34%. Designs of a 1500/sup 0/F modular steam generator and two sizes of matching steam turbines have been completed. The steam generator module uses all Alloy 800 tubes except for two superheater rows of Inconel 617. Its design is based on current production Alloy 800 once-through steam generators currently being introduced into cogeneration combined cycles. A test loop is currently evaluating candidate steam generator tube materials and steam turbine materials at 1500/sup 0/F and 1500 psig. To date, 4000 hours of operation of this loop have been accumulated. The candidate metals after operation in 1500/sup 0/F and 1500 psig steam showed no surface distress. Trade-off studies have been completed on the high temperature steam turbine. Tangential, radial, and axial turbine configurations have been designed and evaluated. The stress analyses of the 1500/sup 0/F steam turbines show that the machine can be operated at 1500/sup 0/F and 1500 psig for over ten years without component replacement when using rotor hub cooling to maintain disk bore temperatures in the 900/sup 0/F range. When applied in back pressure steam, extraction steam, and combined cycle systems the ''1500/sup 0/F steam technology building blocks'' provide full coverage of industrial cogeneration from 4 MW to 25 MW in a single gas turbine and steam turbine installation. A twelve-inch diameter tangential flow turbine has also been designed which is optimum in the 1 to 3 MW power range.

Duffy, T.E.; Schneider, P.H.; Campbell, A.H.; Evensen, O.E.

1987-01-01T23:59:59.000Z

477

Comparative evaluation of surface and downhole steam-generation techniques  

Science Conference Proceedings (OSTI)

It has long been recognized that the application of heat to reservoirs containing high API gravity o