Powered by Deep Web Technologies
Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

DPF Performance with Biodiesel Blends  

Broader source: Energy.gov (indexed) [DOE]

DPF Performance with Biodiesel Blends Aaron Williams, Bob McCormick, Bob Hayes, John Ireland National Renewable Energy Laboratory Howard L. Fang Cummins, Inc. Diesel Engine...

2

DPF 2004 Morgan Wascko  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation Proposed Newcatalyst phases onOrganizationElectronic Reading2Q)38232DOJTuning for Intel ®DPF

3

Effects of Diesel Exhaust Emissions on Soot Oxidation and DPF...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Diesel Exhaust Emissions on Soot Oxidation and DPF Regeneration Effects of Diesel Exhaust Emissions on Soot Oxidation and DPF Regeneration DPF regeneration experiments verified the...

4

Biofuels Impact on DPF Durability  

Broader source: Energy.gov (indexed) [DOE]

Biofuels Impact on DPF Durability Michael J. Lance, Todd J. Toops, Andrew A. Wereszczak, John M.E. Storey, Dane F. Wilson, Bruce G. Bunting, Samuel A. Lewis Sr., and Andrea...

5

Development of Advanced Diesel Particulate Filtration (DPF) Systems  

Broader source: Energy.gov (indexed) [DOE]

a real-time DPF controlmanagement system that can measure the instantaneous mass of soot deposits in a DPF, control DPF regeneration, and provide OBD signals for DPF operation. 3...

6

Electrical diesel particulate filter (DPF) regeneration  

DOE Patents [OSTI]

An exhaust system that processes exhaust generated by an engine includes a diesel particulate filter (DPF) that is disposed downstream of the engine and that filters particulates from the exhaust. An electrical heater is disposed upstream of the DPF and selectively heats the exhaust to initiate combustion of the particulates within the exhaust as it passes therethrough. Heat generated by combustion of the particulates induces combustion of particulates within the DPF.

Gonze, Eugene V; Ament, Frank

2013-12-31T23:59:59.000Z

7

SCR & DPF RETROFITS FOR MOBILE DIESEL ENGINES  

Broader source: Energy.gov (indexed) [DOE]

SCR & DPF RETROFITS FOR MOBILE DIESEL ENGINES Thierry Leprince & Phil Roberts Extengine Transport Systems, LLC 1370 South Acacia Avenue Fullerton, CA - 92831 www.extengine.com...

8

Diesel Particulate Filtration (DPF) Technology: Success stories...  

Broader source: Energy.gov (indexed) [DOE]

Diesel Particulate Filtration (DPF) Technology: Success stories at the High Temperature Materials Laboratory (HTML) User Program Dr. Amit Shyam, ORNL Sponsored by U.S. Department...

9

Diesel Particulate Filtration (DPF) Technology: Success stories...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Success stories at the High Temperature Materials Laboratory (HTML) User Program Diesel Particulate Filtration (DPF) Technology: Success stories at the High Temperature...

10

Electrically heated DPF start-up strategy  

DOE Patents [OSTI]

An exhaust system that processes exhaust generated by an engine has a diesel particulate filter (DPF) that is disposed downstream of the engine and that filters particulates in the exhaust. An electrical heater is disposed upstream of the DPF and selectively heats the exhaust to initiate combustion of the particulates. Heat generated by combustion of particulates in the heater induces combustion of particulates within the DPF. A control module selectively enables current flow to the electrical heater for an initial period of a DPF regeneration cycle, and limits exhaust flow while the electrical heater is heating to a predetermined soot combustion temperature.

Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

2012-04-10T23:59:59.000Z

11

TH.D. STUDENT PROFILES 2006 Entering Class  

E-Print Network [OSTI]

TH.D. STUDENT PROFILES 2006 Entering Class Jeff Conklin-Miller Primary Concentration: Theology ecclesiology, drawing on insights of John Howard Yoder, Rowan Williams, and the Wesleyan tradition. Tommy

Reif, John H.

12

Microwave Regenerated DPF for Auxiliary Power Units and Diesel...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Microwave Regenerated DPF for Auxiliary Power Units and Diesel Hybrid Vehicles Microwave Regenerated DPF for Auxiliary Power Units and Diesel Hybrid Vehicles Microwave regeneration...

13

Development of Advanced Diesel Particulate Filtration (DPF) Systems  

Broader source: Energy.gov (indexed) [DOE]

Foster) - Honda Motor in Japan Complimentary Part Supply - Iljin Electric Co. (DPF heating systems for regeneration) 18 - - Summary Experimental setup for DPF filtration...

14

Development of Advanced Diesel Particulate Filtration (DPF) Systems...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Filters Development of Advanced Diesel Particulate Filtration (DPF) Systems Development of Advanced Diesel Particulate Filtration (DPF) Systems (ANLCorningCaterpillar CRADA)...

15

Development of Advanced Diesel Particulate Filtration (DPF) Systems...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

of Advanced Diesel Particulate Filtration (DPF) Systems (ANLCorningCaterpillar CRADA) Development of Advanced Diesel Particulate Filtration (DPF) Systems Development of...

16

Development of Advanced Diesel Particulate Filtration (DPF) Systems...  

Broader source: Energy.gov (indexed) [DOE]

Particulate Filtration (DPF) Systems Development of Advanced Diesel Particulate Filtration (DPF) Systems (ANLCorningCaterpillar CRADA) Development of Advanced Particulate Filters...

17

Value Analysis of Alternative Diesel Particulate Filter (DPF...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Value Analysis of Alternative Diesel Particulate Filter (DPF) Substrates for Future Diesel Aftertreatment Systems Value Analysis of Alternative Diesel Particulate Filter (DPF)...

18

CFD Analysis of Particle Deposition During DPF Filtration Processes...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Processes CFD Analysis of Particle Deposition During DPF Filtration Processes A 3-D DPF model is developed to predict thermo-physical properties during filtration processes and to...

19

A Revealing Look Inside Passive and Active DPF Regeneration:...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

A Revealing Look Inside Passive and Active DPF Regeneration: In-Situ Optical Analysis of Ash Formation and Transport A Revealing Look Inside Passive and Active DPF Regeneration:...

20

Single Wall Diesel Particulate Filter (DPF) Filtration Efficiency...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Single Wall Diesel Particulate Filter (DPF) Filtration Efficiency Studies Using Laboratory Generated Particles. Single Wall Diesel Particulate Filter (DPF) Filtration Efficiency...

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

DPF2011 1 August 12, 2011  

E-Print Network [OSTI]

irradiation and annealing (biased/no radiation) decrease in optical power is modest annealing in progress "will recover most lost optical power irradiation annealing #12;DPF2011 K.K. Gan 11 Radiation/pions irradiation Results on VCSEL with protons/pions irradiation Summary K.K. Gan #12;K.K. Gan DPF2011 3

Gan, K. K.

22

Neutrino Physics at DPF 2013  

E-Print Network [OSTI]

The field of neutrino physics was covered at DPF 2013 in 32 talks, including three on theoretical advances and the remainder on experiments that spanned at least 17 different detectors. This summary of those talks cannot do justice to the wealth of information presented, but will provide links to other material where possible. There were allso two plenary session contributions on neutrino physics at this meeting: the current status of what we know about neutrino (oscillation) physics was outlined by Huber, and the next steps in long baseline oscillation expeirments were described by Fleming. This article covers a subset of the topics discussed at the meeting, with emphasis given to those talks that showed data or new results.

Deborah A. Harris

2013-10-25T23:59:59.000Z

23

Fuel-Borne Catalyst Assisted DPF regeneration on a Renault truck...  

Broader source: Energy.gov (indexed) [DOE]

Catalyst + ExoClean(tm) DPF with Eolys(tm) FBC -assisted DPF Regeneration Exhaust architecture: SCR (inlet EURO4) ExoClean(tm) DPF (outlet) SCR SCR Exoclean Exoclean (tm) (tm) 1...

24

Development of Advanced Diesel Particulate Filtration (DPF) Systems  

Broader source: Energy.gov (indexed) [DOE]

ILJIN Electric Co., Korea IBIDEN, Japan Relevance and Objectives Existing DPF systems still need to improve filtrationregeneration efficiencies and pressure drops. ...

25

Combination and Integration of DPF-SCR Aftertreatment Technologies  

Broader source: Energy.gov (indexed) [DOE]

control systems Probe interaction of DPF-SCR couples to better understand the optimization of the coupled units Determine system limitations, define basic requirements for...

26

Development of Advanced Diesel Particulate Filtration (DPF) Systems...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

(ANLCorningCaterpillar CRADA) Development of Advanced Diesel Particulate Filtration (DPF) Systems (ANLCorningCaterpillar CRADA) ace22lee.pdf More Documents & Publications...

27

Experimental Studies for DPF and SCR Model, Control System, and...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting ace028johnson2012o.pdf More Documents & Publications Experimental Studies for DPF and SCR Model,...

28

Experimental Studies for DPF and SCR Model, Control System, and...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

and Vehicle Technologies Program Annual Merit Review and Peer Evaluation ace028johnson2011o.pdf More Documents & Publications Experimental Studies for DPF and SCR Model,...

29

A Revealing Look Inside Passive and Active DPF Regeneration...  

Broader source: Energy.gov (indexed) [DOE]

A Revealing Look Inside Passive and Active DPF Regeneration: In-Situ Optical Analysis of Ash Formation and Transport A Consortium to Optimize Lubricant and Diesel Engines for...

30

Application Experience with a Combined SCR and DPF Technology...  

Broader source: Energy.gov (indexed) [DOE]

SCR and DPF Technology for Heavy Duty Diesel Retrofit Ray Conway, Senior Applications Engineer Sougato Chatterjee, Jon Caserta, Ajay Joshi Location: P23 SCRT System NOx...

31

Combination & Integration of DPF-SCR Aftertreatment Technologies...  

Broader source: Energy.gov (indexed) [DOE]

the feasibility of integrating SCR and DPF technologies for the next generation of emission control systems for on-road heavy-truck application deer11rappe.pdf More Documents &...

32

Experimental Studies for DPF and SCR Model, Control System, and...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Merit Review and Peer Evaluation Meeting, June 7-11, 2010 -- Washington D.C. ace028johnson2010o.pdf More Documents & Publications Experimental Studies for DPF and SCR Model,...

33

Low Emissions Potential of EGR-SCR-DPF and Advanced Fuel Formulation...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Emissions Potential of EGR-SCR-DPF and Advanced Fuel Formulation - A Progress Report Low Emissions Potential of EGR-SCR-DPF and Advanced Fuel Formulation - A Progress Report 2003...

34

A Novel Approach in Determining Oil Dilution Level on a DPF Equipped...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

A Novel Approach in Determining Oil Dilution Level on a DPF Equipped Vehicle as a Result of Regeneration A Novel Approach in Determining Oil Dilution Level on a DPF Equipped...

35

Diesel particulate filter (DPF) regeneration by electrical heating of resistive coatings  

DOE Patents [OSTI]

An exhaust system that processes exhaust generated by an engine includes a diesel particulate filter (DPF) that is disposed downstream of the engine and that filters particulates from the exhaust. An electrical heater is integrally formed in an upstream end of the DPF and selectively heats the exhaust to initiate combustion of the particulates within the exhaust as it passes therethrough. Heat generated by combustion of the particulates induces combustion of particulates within the DPF.

Williamson, Weldon S. (Malibu, CA); Gonze, Eugene V. (Pinckney, MI)

2008-12-30T23:59:59.000Z

36

Control System For Cryogenic THD Layering At The National Ignition Facility  

SciTech Connect (OSTI)

The National Ignition Facility (NIF) is the world largest and most energetic laser system for Inertial Confinement Fusion (ICF). In 2010, NIF began ignition experiments using cryogenically cooled targets containing layers of the tritium-hydrogen-deuterium (THD) fuel. The 75 {micro}m thick layer is formed inside of the 2 mm target capsule at temperatures of approximately 18 K. The ICF target designs require sub-micron smoothness of the THD ice layers. Formation of such layers is still an active research area, requiring a flexible control system capable of executing the evolving layering protocols. This task is performed by the Cryogenic Target Subsystem (CTS) of the NIF Integrated Computer Control System (ICCS). The CTS provides cryogenic temperature control with the 1 mK resolution required for beta-layering and for the thermal gradient fill of the capsule. The CTS also includes a 3-axis x-ray radiography engine for phase contrast imaging of the ice layers inside of the plastic and beryllium capsules. In addition to automatic control engines, CTS is integrated with the Matlab interactive programming environment to allow flexibility in experimental layering protocols. The CTS Layering Matlab Toolbox provides the tools for layer image analysis, system characterization and cryogenic control. The CTS Layering Report tool generates qualification metrics of the layers, such as concentricity of the layer and roughness of the growth boundary grooves. The CTS activities are automatically coordinated with other NIF controls in the carefully orchestrated NIF Shot Sequence.

Fedorov, M; Blubaugh, J; Edwards, O; Mauvais, M; Sanchez, R; Wilson, B

2011-03-18T23:59:59.000Z

37

Fuel Efficient Diesel Particulate Filter (DPF) Modeling and Development  

SciTech Connect (OSTI)

The project described in this report seeks to promote effective diesel particulate filter technology with minimum fuel penalty by enhancing fundamental understanding of filtration mechanisms through targeted experiments and computer simulations. The overall backpressure of a filtration system depends upon complex interactions of particulate matter and ash with the microscopic pores in filter media. Better characterization of these phenomena is essential for exhaust system optimization. The acicular mullite (ACM) diesel particulate filter substrate is under continuing development by Dow Automotive. ACM is made up of long mullite crystals which intersect to form filter wall framework and protrude from the wall surface into the DPF channels. ACM filters have been demonstrated to effectively remove diesel exhaust particles while maintaining relatively low backpressure. Modeling approaches developed for more conventional ceramic filter materials, such as silicon carbide and cordierite, have been difficult to apply to ACM because of properties arising from its unique microstructure. Penetration of soot into the high-porosity region of projecting crystal structures leads to a somewhat extended depth filtration mode, but with less dramatic increases in pressure drop than are normally observed during depth filtration in cordierite or silicon carbide filters. Another consequence is greater contact between the soot and solid surfaces, which may enhance the action of some catalyst coatings in filter regeneration. The projecting crystals appear to provide a two-fold benefit for maintaining low backpressures during filter loading: they help prevent soot from being forced into the throats of pores in the lower porosity region of the filter wall, and they also tend to support the forming filter cake, resulting in lower average cake density and higher permeability. Other simulations suggest that soot deposits may also tend to form at the tips of projecting crystals due to the axial velocity component of exhaust moving down the filter inlet channel. Soot mass collected in this way would have a smaller impact on backpressure than soot forced into the flow restrictions deeper in the porous wall structure. This project has focused on the development of computational, analytical, and experimental techniques that are generally applicable to a wide variety of exhaust aftertreatment technologies. By helping to develop improved fundamental understanding pore-scale phenomena affecting filtration, soot oxidation, and NOX abatement, this cooperative research and development agreement (CRADA) has also assisted Dow Automotive in continuing development and commercialization of the ACM filter substrate. Over the course of this research project, ACM filters were successfully deployed on the Audi R10 TDI racecar which won the 24 Hours of LeMans endurance race in 2006, 2007, and 2008; and the 12 Hours of Sebring endurance race in 2006 and 2007. It would not have been possible for the R10 to compete in these traditionally gasoline-dominated events without reliable and effective exhaust particulate filtration. These successes demonstrated not only the performance of automotive diesel engines, but the efficacy of DPF technology as it was being deployed around the world to meet new emissions standards on consumer vehicles. During the course of this CRADA project, Dow Automotive commercialized their ACM DPF technology under the AERIFYTM DPF brand.

Stewart, Mark L.; Gallant, Thomas R.; Kim, Do Heui; Maupin, Gary D.; Zelenyuk, Alla

2010-08-01T23:59:59.000Z

38

Urea SCR and DPF System for Diesel Sport Utility Vehicle Meeting...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

SCR and DPF System for Diesel Sport Utility Vehicle Meeting Tier II Bin 5 DOE and Ford Motor Company Advanced CIDI Emission Control System Development Program (DE-FC26-01NT41103)...

39

Urea SCR and DPF System for Diesel Sport Utility Vehicle Meeting...  

Broader source: Energy.gov (indexed) [DOE]

DOE and Ford Motor Company Advanced CIDI Emission Control System Development Program (DE-FC26-01NT41103) Urea SCR and DPF System for Diesel Sport Utility Vehicle Meeting Tier II...

40

APBF-DEC NOx Adsorber/DPF Project: SUV/Pick-Up Platform  

Broader source: Energy.gov (indexed) [DOE]

Status Principal Investigators: Cynthia Webb Phillip Weber DEER August 25, 2003 APBF-DEC NOx AdsorberDPF Project: SUVPick-Up Platform Program Goals Objectives Light-Duty SUV ...

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

A Novel Three-Phase Rectifier with Reduced THD Gregory Ivensky and Sam Ben-Yaakov  

E-Print Network [OSTI]

- directional switches (such as BJT, MOSFET, IGBT or GTO) and 24 diodes that are switched at low frequency processes within the rectifier bridges proceed instantly. Voltage waveforms of the bridges are presented

42

Impact of Biodiesel Impurities on the Performance and Durability of DOC, DPF and SCR Technologies: Preprint  

SciTech Connect (OSTI)

An accelerated durability test method determined the potential impact of biodiesel ash impurities, including engine testing with multiple diesel particulate filter substrate types, as well as diesel oxidation catalyst and selective catalyst reduction catalysts. The results showed no significant degradation in the thermo-mechanical properties of a DPF after exposure to 150,000-mile equivalent biodiesel ash and thermal aging. However, exposure to 435,000-mile equivalent aging resulted in a 69% decrease in thermal shock resistance. A decrease in DOC activity was seen after exposure to 150,000-mile equivalent aging, resulting in higher hydrocarbon slip and a reduction in NO2 formation. The SCR catalyst experienced a slight loss in activity after exposure to 435,000-mile equivalent aging. The SCR catalyst, placed downstream of the DPF and exposed to B20 exhaust suffered a 5% reduction in overall NOx conversion activity over the HDDT test cycle. It is estimated that the additional ash from 150,000 miles of biodiesel use would also result in a moderate increases in exhaust backpressure for a DPF. The results of this study suggest that long-term operation with B20 at the current specification limits for alkali and alkaline earth metal impurities will adversely impact the performance of DOC, DPF and SCR systems.

Williams, A.; McCormick, R.; Luecke, J.; Brezny, R.; Geisselmann, A.; Voss, K.; Hallstrom, K.; Leustek, M.; Parsons, J.; Abi-Akar, H.

2011-04-01T23:59:59.000Z

43

Individual and synergistic effects of lubricant additive (Ca, Mg, Zn) combinations on ash characteristics and DPF performance  

E-Print Network [OSTI]

Diesel particulate filters (DPF) are devices that trap hazardous particulate matter from diesel engine exhaust in order to meet increasingly strict particle emissions regulations. Diesel exhaust particulates mainly include ...

Chiou, Casey (Casey Jianzhi)

2013-01-01T23:59:59.000Z

44

K.K. Gan DPF/JPS06 1 Bandwidths of Micro Twisted-Pair Cables  

E-Print Network [OSTI]

/fall time after irradiation? What is optical power after irradiation? What current is needed for annealing during irradiation SLHC AOC 71 MRad 0.0 0.3 0.6 0.9 1.2 1.5 1.8 0 100 200 300 400 Time (Hours) DataOpticalPK.K. Gan DPF/JPS06 1 Bandwidths of Micro Twisted-Pair Cables and Fusion Spliced SIMM-GRIN Fibers

Gan, K. K.

45

Impact of Biodiesel Impurities on the Performance and Durability of DOC, DPF and SCR Technologies  

SciTech Connect (OSTI)

It is estimated that operating continuously on a B20 fuel containing the current allowable ASTM specification limits for metal impurities in biodiesel could result in a doubling of ash exposure relative to lube-oil derived ash. The purpose of this study was to determine if a fuel containing metals at the ASTM limits could cause adverse impacts on the performance and durability of diesel emission control systems. An accelerated durability test method was developed to determine the potential impact of these biodiesel impurities. The test program included engine testing with multiple DPF substrate types as well as DOC and SCR catalysts. The results showed no significant degradation in the thermo-mechanical properties of cordierite, aluminum titanate, or silicon carbide DPFs after exposure to 150,000 mile equivalent biodiesel ash and thermal aging. However, exposure of a cordierite DPF to 435,000 mile equivalent aging resulted in a 69% decrease in the thermal shock resistance parameter. It is estimated that the additional ash from 150,000 miles of biodiesel use would also result in a moderate increases in exhaust backpressure for a DPF. A decrease in DOC activity was seen after exposure to 150,000 mile equivalent aging, resulting in higher HC slip and a reduction in NO{sub 2} formation. The metal-zeolite SCR catalyst experienced a slight loss in activity after exposure to 435,000 mile equivalent aging. This catalyst, placed downstream of the DPF, showed a 5% reduction in overall NOx conversion activity over the HDDT test cycle.

Williams, A.; McCormick, R.; Luecke, J.; Brezny, R.; Geisselmann, A.; Voss, K.; Hallstrom, K.; Leustek, M.; Parsons, J.; Abi-Akar, H.

2011-06-01T23:59:59.000Z

46

Molecular cloning and sequence of the thdF gene involved in the thiophene and furan oxidation by Escherichia coli  

SciTech Connect (OSTI)

Since sulfur dioxide emission from burning high sulfur coals is a major contributor to acid rain, it is important to develop bacteria which are capable of efficiently removing the sulfur from coal before combustion. Inorganic sulfur can be removed from coal by certain strains of Thiobacillus or Sulfolobus; however the organic sulfur remains intransigent. Since high sulfur Illinois coals typically contain 60% to 70% of their sulfur in the form of the heterocyclic thiophene ring we have started to investigate the biodegradation of derivatives of thiophene and the corresponding oxygen heterocycle, furan. Our previous work resulted in the isolation of a triple mutant, NAR30, capable of oxidizing a range of furan and thiophene derivatives. However, NAR30 does not completely degrade thiophenes or furans and its oxidation of these compounds is slow and inefficient. We decided to clone the thd genes both in order to increase the efficiency of degradation and to investigate the nature of the reactions involved. 37 refs., 4 figs., 3 tabs.

Alam, K.Y.; Clark, D.P.

1990-01-01T23:59:59.000Z

47

APBF-DEC NOx Adsorber/DPF Project: SUV/Pick-Up Platform | Department of  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartment of Energy 601 High IntegrityEnergy NOx Adsorber/DPF Project:

48

Emissions From Various Biodiesel Sources Compared to a Range of Diesel Fuels in DPF Equipped Diesel Engines  

SciTech Connect (OSTI)

The purpose of this study was to measure the impact of various sources of petroleum-based and bio-based diesel fuels on regulated emissions and fuel economy in diesel particulate filter (DPF) equipped diesel engines. Two model year 2008 diesel engines were tested with nine fuels including a certification ultra-low sulfur diesel (ULSD), local ULSD, high aromatic ULSD, low aromatic ULSD, and twenty percent blends of biodiesel derived from algae, camelina, soy, tallow, and yellow grease. Regulated emissions were measured over the heavy duty diesel transient test cycle. Measurements were also made of DPF-out particle size distribution and total particle count from a 13-mode steady state test using a fast mobility particle sizer. Test engines were a 2008 Cummins ISB and a 2008 International Maxx Force 10, both equipped with actively regenerated DPFs. Fuel consumption was roughly 2% greater over the transient test cycle for the B20 blends versus certification ULSD in both engines, consistent with the slightly lower energy content of biodiesel. Unlike studies conducted on older model engines, these engines equipped with diesel oxidation catalysts and DPFs showed small or no measurable fuel effect on the tailpipe emissions of total hydrocarbons (THC), carbon monoxide (CO) and particulate matter (PM). No differences in particle size distribution or total particle count were seen in a comparison of certification ULSD and B20 soy, with the exception of engine idling conditions where B20 produced a small reduction in the number of nucleation mode particles. In the Cummins engine, B20 prepared from algae, camelina, soy, and tallow resulted in an approximately 2.5% increase in nitrogen oxides (NO{sub x}) compared to the base fuel. The International engine demonstrated a higher degree of variability for NO{sub x} emissions, and fuel effects could not be resolved (p > 0.05). The group of petroleum diesel test fuels produced a range of NO{sub x} emissions very similar to that caused by blending of biodiesel. Test cycles where an active regeneration of the DPF occurred resulted in a nearly threefold increase in NO{sub x} emissions and a 15% increase in fuel consumption. The full quantification of DPF regeneration events further complicates the accurate calculation of fuel impacts on emissions and fuel consumption.

Williams, A.; Burton, J.; Christensen, E.; McCormick, R. L.; Tester, J.

2011-01-01T23:59:59.000Z

49

PERFORMANCE AND DURABILITY OF THE PSA PEUGEOT CITROEN'S DPF SYSTEM ON A TAXI FLEET IN THE PARIS AREA  

SciTech Connect (OSTI)

The use of Diesel engines has strongly increased during the last years and now represents 40% of the sales in Europe and up to 50% of the number of cars in circulation for some countries. This success is linked not only to the economical aspect of the use of such vehicles, but also to the recent technological improvements of these engines. The new technical solutions (high pressure direct injection, turbocharger) have indeed allowed the increase of these engine performances while decreasing their fuel consumption, pollutant emissions and noise level. From an environment point of view, Diesel engines are nevertheless penalized by their particulates and NOx emissions. The study and the treatment of the particulate, highly criticized for their potential impact on health, are the subject of numerous works of characterizations and developments. PSA Peugeot Citroen has recently (2000) launched its particulate filter technology on several types of vehicles (500,000 vehicles with DPF have been sold today). In order to evaluate the durability of this technology over a long period of time, a study program has been set-up by ADEME (French Environmental Agency), IFP Powertrain, PSA Peugeot Citroen and Taxis G7 (a Parisian taxis Company). The objective is to study the evolution of five taxis and their after-treatment system performances over 80,000km mileage--which corresponds to the recommended mileage before the first DPF maintenance--in hard urban driving conditions, as well over 120,000km, after the DPF maintenance and remanufacturing. More specifically, the following evaluations are being performed at regular intervals (around 20,000km): regulated gaseous pollutant emissions on NEDC cycle, particulate emissions and unregulated pollutant emissions. The results obtained until now have not shown any degradation of the particulate filter efficiency (more than 90%). This paper presents the methodology set-up, and the explanation of the first results obtained. Indeed, a more specific study has shown that most of the aerosols, measured with SMPS are composed of liquid fractions, mainly sulfates due to the sulphur coming from the fuel but also from the lubricant. The impact of sulfates stored on the catalyst surface during low temperature running phases and removed during high temperature running phases has been also outlined.

COROLLER, P; PLASSAT, G

2003-08-24T23:59:59.000Z

50

PROCEEDINGS OF THE 1983 DPF WORKSHOP ON COLLIDER DETECTORS: PRESENT CAPABILITIES AND FUTURE POSSIBILITIES, FEB. 28 - MARCH 4, 1983.  

SciTech Connect (OSTI)

It is useful before beginning our work here to restate briefly the purpose of this workshop in the light of the present circumstances of elementary particle physics in the U.S. The goal of our field is easily stated in a general way: it is to reach higher center of mass energies and higher luminosities while employing more sensitive and more versatile event detectors, all in order to probe more deeply into the physics of elementary particles. The obstacles to achieving this goal are equally apparent. Escalating costs of construction and operation of our facilities limit alternatives and force us to make hard choices among those alternatives. The necessity to be highly selective in the choice of facilities, in conjunction with the need for increased manpower concentrations to build accelerators and mount experiments, leads to complex social problems within the science. As the frontier is removed ever further, serious technical difficulties and limitations arise. Finally, competition, much of which is usually healthy, now manifests itself with greater intensity on a regional basis within our country and also on an international scale. In the far ({ge}20 yr) future, collaboration on physics facilities by two or more of the major economic entities of the world will possibly be forthcoming. In the near future, we are left to bypass or overcome these obstacles on a regional scale as best we can. The choices we face are in part indicated in the list of planned and contemplated accelerators shown in Table I. The facilities indicated with an asterisk pose immediate questions: (1) Do we need them all and what should be their precise properties? (2) How are the ones we choose to be realized? (3) What is the nature of the detectors to exploit those facilities? (4) How do we respond to the challenge of higher luminosity as well as higher energy in those colliders? The decision-making process in this country and elsewhere depends on the answers to these technical questions. Those relating to the accelerators have been and continue to be addressed in many workshops and studies. For example, a workshop organized by M. Tigner will begin to study the means of achieving a very high energy (10 TeV x 10 TeV) hadron collider; this is scheduled at the end of March at Cornell University. If it seems desirable, continuity in the form of subsequent workshops on technical questions relating to accelerator facilities might be provided by the Division of Particles and Fields (DPF) of the American Physical Society, as it is doing here for collider detectors. The workshop we are about to begin is intended to address questions (3) and (4) above. It is an attempt to look at those questions from a broad point of view by assembling a wide spectrum of experts from universities and national and international laboratories. It is planned to make the proceedings of the workshop available to the 1983 Woods Hole Sub-Panel of HEPAP which is charged with the responsibility for recommendations concerning the choices that face the U.S. program. This is the main reason that we are meeting at the present time. In this connection, it is worth emphasizing that the DPF is an organization of roughly 3000 physicists from universities and national laboratories. It is an independent organization not affiliated with any laboratory or government agency. Most important, it is not a decision-making body or a lobbying group. Its aim is to provide neutral arenas for scholarly discussion of the salient issues of our area of science, e.g., the DPF Summer Study on Particle Physics and Facilities in Snowmass, Colorado, in the summer of 1982. For this reason it concentrates on technical questions such as those of this Workshop.

Loken Ed, S.C.; Nemethy Ed, P.

1983-04-01T23:59:59.000Z

51

High Voltage Safety Act  

Broader source: Energy.gov [DOE]

The purpose of the High Voltage Safety Act is to prevent injury to persons and property and interruptions of utility service resulting from accidental or inadvertent contact with high-voltage...

52

Automatic voltage imbalance detector  

DOE Patents [OSTI]

A device for indicating and preventing damage to voltage cells such as galvanic cells and fuel cells connected in series by detecting sequential voltages and comparing these voltages to adjacent voltage cells. The device is implemented by using operational amplifiers and switching circuitry is provided by transistors. The device can be utilized in battery powered electric vehicles to prevent galvanic cell damage and also in series connected fuel cells to prevent fuel cell damage.

Bobbett, Ronald E. (Los Alamos, NM); McCormick, J. Byron (Los Alamos, NM); Kerwin, William J. (Tucson, AZ)

1984-01-01T23:59:59.000Z

53

Optical voltage reference  

DOE Patents [OSTI]

An optical voltage reference for providing an alternative to a battery source is described. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function. 2 figures.

Rankin, R.; Kotter, D.

1994-04-26T23:59:59.000Z

54

Voltage Control Technical Conference  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Intro Voltage Control Conference - BPA Active Power Control in Wind Parks - Siemens Interconnection Criteria for Frequency Response Requirements - NERC Model Validation...

55

Voltage verification unit  

DOE Patents [OSTI]

A voltage verification unit and method for determining the absence of potentially dangerous potentials within a power supply enclosure without Mode 2 work is disclosed. With this device and method, a qualified worker, following a relatively simple protocol that involves a function test (hot, cold, hot) of the voltage verification unit before Lock Out/Tag Out and, and once the Lock Out/Tag Out is completed, testing or "trying" by simply reading a display on the voltage verification unit can be accomplished without exposure of the operator to the interior of the voltage supply enclosure. According to a preferred embodiment, the voltage verification unit includes test leads to allow diagnostics with other meters, without the necessity of accessing potentially dangerous bus bars or the like.

Martin, Edward J. (Virginia Beach, VA)

2008-01-15T23:59:59.000Z

56

Voltage balanced multilevel voltage source converter system  

DOE Patents [OSTI]

A voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

57

Voltage balanced multilevel voltage source converter system  

DOE Patents [OSTI]

Disclosed is a voltage balanced multilevel converter for high power AC applications such as adjustable speed motor drives and back-to-back DC intertie of adjacent power systems. This converter provides a multilevel rectifier, a multilevel inverter, and a DC link between the rectifier and the inverter allowing voltage balancing between each of the voltage levels within the multilevel converter. The rectifier is equipped with at least one phase leg and a source input node for each of the phases. The rectifier is further equipped with a plurality of rectifier DC output nodes. The inverter is equipped with at least one phase leg and a load output node for each of the phases. The inverter is further equipped with a plurality of inverter DC input nodes. The DC link is equipped with a plurality of rectifier charging means and a plurality of inverter discharging means. The plurality of rectifier charging means are connected in series with one of the rectifier charging means disposed between and connected in an operable relationship with each adjacent pair of rectifier DC output nodes. The plurality of inverter discharging means are connected in series with one of the inverter discharging means disposed between and connected in an operable relationship with each adjacent pair of inverter DC input nodes. Each of said rectifier DC output nodes are individually electrically connected to the respective inverter DC input nodes. By this means, each of the rectifier DC output nodes and each of the inverter DC input nodes are voltage balanced by the respective charging and discharging of the rectifier charging means and the inverter discharging means. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-07-01T23:59:59.000Z

58

High voltage DC power supply  

DOE Patents [OSTI]

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

Droege, T.F.

1989-12-19T23:59:59.000Z

59

High voltage DC power supply  

DOE Patents [OSTI]

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

Droege, Thomas F. (Batavia, IL)

1989-01-01T23:59:59.000Z

60

ABBGroup-1-High voltage lab  

E-Print Network [OSTI]

oscillations are due to travelling waves in the heating volume. #12;©ABBGroup-9- 3-Sep-07 2. High voltage phase interrupts the injected current, it is stressed by the transient recovery voltage (TRV) oscillating©ABBGroup-1- 3-Sep-07 High voltage lab Research on high voltage gas circuit breakers Nils P. Basse

Basse, Nils Plesner

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

DPF heater attachment mechanisms  

DOE Patents [OSTI]

An exhaust filter system includes a particulate filter (PF) that is disposed downstream from an engine. The PF filters particulates within an exhaust from the engine. A heating element heats particulate matter in the PF. A fastener limits expansion movement of the heating element relative to the PF.

Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

2011-04-26T23:59:59.000Z

62

Electron launching voltage monitor  

DOE Patents [OSTI]

An electron launching voltage monitor measures MITL voltage using a relationship between anode electric field and electron current launched from a cathode-mounted perturbation. An electron launching probe extends through and is spaced from the edge of an opening in a first MITL conductor, one end of the launching probe being in the gap between the MITL conductor, the other end being adjacent a first side of the first conductor away from the second conductor. A housing surrounds the launching probe and electrically connects the first side of the first conductor to the other end of the launching probe. A detector detects the current passing through the housing to the launching probe, the detected current being representative of the voltage between the conductors. 5 figs.

Mendel, C.W.; Savage, M.E.

1992-03-17T23:59:59.000Z

63

Voltage controlled current source  

DOE Patents [OSTI]

A seven decade, voltage controlled current source is described for use in testing intermediate range nuclear instruments that covers the entire test current range of from 10 picoamperes to 100 microamperes. High accuracy is obtained throughout the entire seven decades of output current with circuitry that includes a coordinated switching scheme responsive to the input signal from a hybrid computer to control the input voltage to an antilog amplifier, and to selectively connect a resistance to the antilog amplifier output to provide a continuous output current source as a function of a preset range of input voltage. An operator controlled switch provides current adjustment for operation in either a real-time simulation test mode or a time response test mode.

Casne, Gregory M. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

64

High voltage pulse conditioning  

DOE Patents [OSTI]

Apparatus for conditioning high voltage pulses from particle accelerators in order to shorten the rise times of the pulses. Flashover switches in the cathode stalk of the transmission line hold off conduction for a determinable period of time, reflecting the early portion of the pulses. Diodes upstream of the switches divert energy into the magnetic and electrostatic storage of the capacitance and inductance inherent to the transmission line until the switches close.

Springfield, Ray M. (Sante Fe, NM); Wheat, Jr., Robert M. (Los Alamos, NM)

1990-01-01T23:59:59.000Z

65

Charge-pump voltage converter  

DOE Patents [OSTI]

A charge-pump voltage converter for converting a low voltage provided by a low-voltage source to a higher voltage. Charge is inductively generated on a transfer rotor electrode during its transit past an inductor stator electrode and subsequently transferred by the rotating rotor to a collector stator electrode for storage or use. Repetition of the charge transfer process leads to a build-up of voltage on a charge-receiving device. Connection of multiple charge-pump voltage converters in series can generate higher voltages, and connection of multiple charge-pump voltage converters in parallel can generate higher currents. Microelectromechanical (MEMS) embodiments of this invention provide a small and compact high-voltage (several hundred V) voltage source starting with a few-V initial voltage source. The microscale size of many embodiments of this invention make it ideally suited for MEMS- and other micro-applications where integration of the voltage or charge source in a small package is highly desirable.

Brainard, John P. (Albuquerque, NM); Christenson, Todd R. (Albuquerque, NM)

2009-11-03T23:59:59.000Z

66

INTEGRATED GHz VOLTAGE CONTROLLED OSCILLATORS  

E-Print Network [OSTI]

INTEGRATED GHz VOLTAGE CONTROLLED OSCILLATORS Peter Kinget Bell Labs - Lucent Technologies Murray Hill, NJ (USA) Abstract The voltage controlled oscillator (VCO) is a critical sub. We focus on the de- sign of a critical sub-block: the voltage controlled oscillator (VCO). We review

Kinget, Peter

67

Ignition distributor voltage generator  

SciTech Connect (OSTI)

This patent describes a voltage pulse generator and ignition distributor comprising, a base, a shaft rotatably supported by the base, a distributor cap supported by the base having a center electrode and circumferentially spaced outer electrodes. The pulse generator and ignition distribution also include a first rotor driven by the shaft formed of electrical insulating material having electrically conductive means connected to the center terminal and a portion that rotates past the outer electrodes. The portion of the electrically conductive means that rotates past the outer electrodes is spaced from the outer electrodes to form a gap therebetween. A voltage pulse generator comprises a second rotor driven by the shaft, at least one permanent magnet and an annular pickup coil supported by the base. The pickup coil has inner turns and outer turns, the beginning turn of the inner turns connected to a first lead and the last turn of the outer turns connected to a second lead, the outer turns enclosing the inner turns. The pickup coil also has a circuit connected directly between the second lead and ground which is operative to provide a direct conductive path to ground for high frequency energy capacitively coupled to the outer turns from the gap discharge between the electrically conductive means of the first rotor and an outer electrode, the outer turns forming a grounded shield for the inner turns.

Boyer, J.A.

1986-11-04T23:59:59.000Z

68

Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect (OSTI)

An update is given on the work of the PV Quality Assurance Task Force; Group 3: studying the effects of humidity, temperature, and voltage bias.

Wohlgemuth, J.

2012-03-01T23:59:59.000Z

69

Modeling gated neutron images of THD capsules  

SciTech Connect (OSTI)

Time gating a neutron detector 28m from a NIF implosion can produce images at different energies. The brighter image near 14 MeV reflects the size and symmetry of the capsule 'hot spot'. Scattered neutrons, {approx}9.5-13 MeV, reflect the size and symmetry of colder, denser fuel, but with only {approx}1-7% of the neutrons. The gated detector records both the scattered neutron image, and, to a good approximation, an attenuated copy of the primary image left by scintillator decay. By modeling the imaging system the energy band for the scattered neutron image (10-12 MeV) can be chosen, trading off the decayed primary image and the decrease of scattered image brightness with energy. Modeling light decay from EJ399, BC422, BCF99-55, Xylene, DPAC-30, and Liquid A leads to a preference from BCF99-55 for the first NIF detector, but DPAC 30 and Liquid A would be preferred if incorporated into a system. Measurement of the delayed light from the NIF scintillator using implosions at the Omega laser shows BCF99-55 to be a good choice for down-scattered imaging at 28m.

Wilson, Douglas Carl [Los Alamos National Laboratory; Grim, Gary P [Los Alamos National Laboratory; Tregillis, Ian L [Los Alamos National Laboratory; Wilke, Mark D [Los Alamos National Laboratory; Morgan, George L [Los Alamos National Laboratory; Loomis, Eric N [Los Alamos National Laboratory; Wilde, Carl H [Los Alamos National Laboratory; Oertel, John A [Los Alamos National Laboratory; Fatherley, Valerie E [Los Alamos National Laboratory; Clark, David D [Los Alamos National Laboratory; Schmitt, Mark J [Los Alamos National Laboratory; Merrill, Frank E [Los Alamos National Laboratory; Wang, Tai - Sen F [Los Alamos National Laboratory; Danly, Christopher R [Los Alamos National Laboratory; Batha, Steven H [Los Alamos National Laboratory; Patel, M [LLNL; Sepke, S [LLNL; Hatarik, R [LLNL; Fittinghoff, D [LLNL; Bower, D [LLNL; Marinak, M [LLNL; Munro, D [LLNL; Moran, M [LLNL; Hilko, R [NSTEC; Frank, M [LLNL; Buckles, R [NSTEC

2010-01-01T23:59:59.000Z

70

Transient voltage oscillations in coils  

SciTech Connect (OSTI)

Magnet coils may be excited into internal voltage oscillations by transient voltages. Such oscillations may electrically stress the magnet's dielectric components to many times its normal stress. This may precipitate a dielectric failure, and the attendant prolonged loss of service and costly repair work. Therefore, it is important to know the natural frequencies of oscillations of a magnet during the design stage, and to determine whether the expected switching transient voltages can excite the magnet into high-voltage internal oscillations. The series capacitance of a winding significantly affects its natural frequencies. However, the series capacitance is difficult to calculate, because it may comprise complex capacitance network, consisting of intra- and inter-coil turn-to-turn capacitances of the coil sections. A method of calculating the series capacitance of a winding is proposed. This method is rigorous but simple to execute. The time-varying transient voltages along the winding are also calculated.

Chowdhuri, P.

1985-01-01T23:59:59.000Z

71

Low voltage nonprimary explosive detonator  

DOE Patents [OSTI]

A low voltage, electrically actuated, nonprimary explosive detonator is disclosed wherein said detonation is achieved by means of an explosive train in which a deflagration-to-detonation transition is made to occur. The explosive train is confined within a cylindrical body and positioned adjacent to low voltage ignition means have electrical leads extending outwardly from the cylindrical confining body. Application of a low voltage current to the electrical leads ignites a self-sustained deflagration in a donor portion of the explosive train which then is made to undergo a transition to detonation further down the train.

Dinegar, Robert H. (Los Alamos, NM); Kirkham, John (Newbury, GB2)

1982-01-01T23:59:59.000Z

72

Voltage tunable microwave ferrite resonator  

E-Print Network [OSTI]

A novel method of implementing a tunable resonator using an applied voltage is presented. Stress is used to tune a microstrip resonator fabricated on a polycrystalline ferrite substrate. The stress was applied either ...

Oates, Daniel E.

73

Saving Megawatts with Voltage Optimization  

E-Print Network [OSTI]

that had been installed at several electric utility distribution substations in the U.S. and Canada. These systems, being operated in Conservation Voltage Regulation mode, have provided significant energy conservation where they have been installed...

Wilson, T.; Bell, D.

2010-01-01T23:59:59.000Z

74

Voltage, energy and power in electric circuits  

E-Print Network [OSTI]

Voltage, energy and power in electric circuits Science teaching unit #12;Disclaimer The Department-2008DVD-EN Voltage, energy and power in electric circuits #12;#12;© Crown copyright 2008 1The National Strategies | Secondary Voltage, energy and power in electric circuits 00094-2008DVD-EN Contents Voltage

Berzins, M.

75

Ancillary service details: Voltage control  

SciTech Connect (OSTI)

Voltage control is accomplished by managing reactive power on an alternating-current power system. Reactive power can be produced and absorbed by both generation and transmission equipment. Reactive-power devices differ substantially in the magnitude and speed of response and in their capital costs. System operators, transmission owners, generators, customers, power marketers, and government regulators need to pay close attention to voltage control as they restructure the U.S. electricity industry. Voltage control can affect reliability and commerce in three ways: (1) Voltages must be maintained within an acceptable range for both customer and power-system equipment to function properly. (2) The movement of reactive power consumes transmission resources, which limits the ability to move real power and worsens congestion. (3) The movement of reactive power results in real-power losses. When generators are required to supply excessive amounts of reactive power, their real-power production must be curtailed. These opportunity costs are not currently compensated for in most regions. Current tariffs are based on embedded costs. These embedded-cost tariffs average about $0.51/MWh, equivalent to $1.5 billion annually for the United States as a whole. Although this cost is low when compared with the cost of energy, it still aggregates to a significant amount of money. This report takes a basic look at why the power system requires reactive power (an appendix explains the fundamentals of real and reactive power). The report then examines the various types of generation and transmission resources used to supply reactive power and to control voltage. Finally it discusses how these resources are deployed and paid for in several reliability regions around the country. As the U.S. electricity industry is restructured, the generation, transmission, and system-control equipment and functions that maintain voltages within the appropriate ranges are being deintegrated.

Kirby, B.; Hirst, E.

1997-12-01T23:59:59.000Z

76

Modulated voltage metastable ionization detector  

SciTech Connect (OSTI)

Metastable ionization detectors used for chromatographic analysis usually employa fixed high voltage for the ionization potential. For this reason, the operating range is limited to about three orders of magnitude. By use of the technique disclosed in the instant invention, operating ranges of about nine orders of magnitude are obtained. The output current from a metastable ionization detector (MID) is applied to a modulation voltage circuit. An adjustment is made to balance out the background current, and an output current, above background, is applied to an input of a strip chart recorder. For low level concentrations, i.e., low detected output current, the ionization potential will be at a maximum and the metastable ionization detector will operate at its most sensitive level. When the detected current from the metastable ionization detector increases above a predetermined threshold level, a voltage control circuit is activated which turns on a high voltage transistor which acts to reduce the ionization potential. The ionization potential applied to the metastable ionization detector is then varied so as to maintain the detected signal level constant. The variation in ionization potential is now related to the concentration fo the constituent and a representative amplitude is applied to another input of said strip chart recorder.

Carle, G. C.; Humphry, D. E.; Kojiro, D. R.

1985-08-27T23:59:59.000Z

77

Biofuels Impact on DPF Durability  

Broader source: Energy.gov (indexed) [DOE]

materials with acids found in biodiesel exhaust condensate. - Measured elastic and fracture properties of SiC and cordierite materials using FEA-based flexure testing. * FY12 -...

78

High voltage photovoltaic power converter  

DOE Patents [OSTI]

An array of independently connected photovoltaic cells on a semi-insulating substrate contains reflective coatings between the cells to enhance efficiency. A uniform, flat top laser beam profile is illuminated upon the array to produce electrical current having high voltage. An essentially wireless system includes a laser energy source being fed through optic fiber and cast upon the photovoltaic cell array to prevent stray electrical signals prior to use of the current from the array. Direct bandgap, single crystal semiconductor materials, such as GaAs, are commonly used in the array. Useful applications of the system include locations where high voltages are provided to confined spaces such as in explosive detonation, accelerators, photo cathodes and medical appliances.

Haigh, Ronald E. (Arvada, CO); Wojtczuk, Steve (Cambridge, MA); Jacobson, Gerard F. (Livermore, CA); Hagans, Karla G. (Livermore, CA)

2001-01-01T23:59:59.000Z

79

Onset voltage of corona on coated conductors  

SciTech Connect (OSTI)

This paper is aimed for investigating the effect of surface coating on the positive and negative onset voltages of corona from stressed conductor as a pre-requisite for onset-voltage calculation. The electric field is accurately calculated by the charge simulation technique. The calculated onset voltages agreed satisfactorily with those measured experimentally for bare conductors. The effect of coating-layer thickness and permittivity as well as conductor radius and height on the onset-voltage values is discussed.

Abdel-Salam, M. [Assiut Univ. (Egypt). Electrical Engineering Dept.; Abo-Shal, Y. [SCECO-East, Dammam (Saudi Arabia). Electrical Engineering Div.

1995-12-31T23:59:59.000Z

80

Low power, scalable multichannel high voltage controller  

DOE Patents [OSTI]

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

2006-03-14T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Low power, scalable multichannel high voltage controller  

DOE Patents [OSTI]

A low voltage control circuit is provided for individually controlling high voltage power provided over bus lines to a multitude of interconnected loads. An example of a load is a drive for capillary channels in a microfluidic system. Control is distributed from a central high voltage circuit, rather than using a number of large expensive central high voltage circuits to enable reducing circuit size and cost. Voltage is distributed to each individual load and controlled using a number of high voltage controller channel switches connected to high voltage bus lines. The channel switches each include complementary pull up and pull down photo isolator relays with photo isolator switching controlled from the central high voltage circuit to provide a desired bus line voltage. Switching of the photo isolator relays is further controlled in each channel switch using feedback from a resistor divider circuit to maintain the bus voltage swing within desired limits. Current sensing is provided using a switched resistive load in each channel switch, with switching of the resistive loads controlled from the central high voltage circuit.

Stamps, James Frederick (Livermore, CA); Crocker, Robert Ward (Fremont, CA); Yee, Daniel Dadwa (Dublin, CA); Dils, David Wright (Fort Worth, TX)

2008-03-25T23:59:59.000Z

82

Dynamic Voltage Regulation Using Distributed Energy Resources  

SciTech Connect (OSTI)

Many distributed energy resources (DE) are near load centres and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide ancillary services such as voltage regulation, nonactive power compensation, and power factor correction. A synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Voltage control schemes of the inverter and the synchronous condenser are developed. The experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously, while the dynamic response of the inverter is faster than the synchronous condenser; and that integrated voltage regulation (multiple DE perform voltage regulation) can increase the voltage regulation capability, increase the lifetime of the equipment, and reduce the capital and operation costs.

Xu, Yan [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL

2007-01-01T23:59:59.000Z

83

Voltage Vehicles | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:Seadov PtyInformationSEDS data Jump to: navigation, search ToolVoith HydroVoltage

84

Wind Power Plant Voltage Stability Evaluation: Preprint  

SciTech Connect (OSTI)

Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

Muljadi, E.; Zhang, Y. C.

2014-09-01T23:59:59.000Z

85

High voltage load resistor array  

DOE Patents [OSTI]

A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

Lehmann, Monty Ray (Smithfield, VA)

2005-01-18T23:59:59.000Z

86

Group 3: Humidity, Temperature, and Voltage (Presentation)  

SciTech Connect (OSTI)

Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-05-01T23:59:59.000Z

87

High Voltage Electrolyte for Lithium Batteries  

Broader source: Energy.gov (indexed) [DOE]

battery using high voltage high energy cathode materials to enable large-scale, cost competitive production of the next generation of electric-drive vehicles. To...

88

Capturing power at higher voltages from arrays of microbial fuel cells without voltage reversal  

E-Print Network [OSTI]

is too low to be used directly for many practical applications. For example, a single light emitting diode (LED) requires a minimum voltage of 2 V.2 Thus, effective methods of boosting MFC voltages

89

The Constant Voltage Transformer (CVT) for Mitigating Effects of Voltage Sags on Industrial Equipment  

E-Print Network [OSTI]

) an increase in loads that use power electronics in some type of power conversion configuration [1][2]. This paper presents applications of the constant-voltage transformer (CVT) for mitigating the effects of electric service voltage sags on industrial...

Ferraro, R. J.; Osborne, R.; Stephens, R.

90

Voltage Collapse SimulationVoltage Collapse Simulation (Eastern Interconnection(Eastern Interconnection  

E-Print Network [OSTI]

PSERC Voltage Collapse SimulationVoltage Collapse Simulation (Eastern Interconnection(Eastern Interconnection Scenario)Scenario) Simulation Prepared by Dennis J. RaySimulation Prepared by Dennis J. Ray Interconnection based on a series of generator and line outages. An actual voltage collapse may not occur due

91

DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION  

E-Print Network [OSTI]

1 DESIGN AND IMPLEMENTATION OF A FUZZY LOGIC-BASED VOLTAGE CONTROLLER FOR VOLTAGE REGULATION In this paper the design and implementation of a fuzzy logic-based controller is described for regulating the output voltage of a synchronous generator. An automated fuzzy logic-based control strategy is presented

LaMeres, Brock J.

92

Optimal Power Flow Incorporating Voltage Collapse Constraints  

E-Print Network [OSTI]

Optimal Power Flow Incorporating Voltage Collapse Constraints William Rosehart Claudio Ca on the current operating con- ditions is presented. Second, an Optimal Power Flow formulation that incorporates: Voltage Collapse, Optimal Power Flow, Bifur- cations. I. Introduction As open-access market principles

Cañizares, Claudio A.

93

Voltage regulation in linear induction accelerators  

DOE Patents [OSTI]

Improvement in voltage regulation in a Linear Induction Accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance.

Parsons, William M. (Santa Fe, NM)

1992-01-01T23:59:59.000Z

94

Voltage regulation in linear induction accelerators  

DOE Patents [OSTI]

Improvement in voltage regulation in a linear induction accelerator wherein a varistor, such as a metal oxide varistor, is placed in parallel with the beam accelerating cavity and the magnetic core is disclosed. The non-linear properties of the varistor result in a more stable voltage across the beam accelerating cavity than with a conventional compensating resistance. 4 figs.

Parsons, W.M.

1992-12-29T23:59:59.000Z

95

Non-contact current and voltage sensor  

SciTech Connect (OSTI)

A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

Carpenter, Gary D; El-Essawy, Wael; Ferreira, Alexandre Peixoto; Keller, Thomas Walter; Rubio, Juan C; Schappert, Michael A

2014-03-25T23:59:59.000Z

96

Flexible method for monitoring fuel cell voltage  

DOE Patents [OSTI]

A method for equalizing the measured voltage of each cluster in a fuel cell stack wherein at least one of the clusters has a different number of cells than the identical number of cells in the remaining clusters by creating a pseudo voltage for the different cell numbered cluster. The average cell voltage of the all of the cells in the fuel cell stack is calculated and multiplied by a constant equal to the difference in the number of cells in the identical cell clusters and the number of cells in the different numbered cell cluster. The resultant product is added to the actual voltage measured across the different numbered cell cluster to create a pseudo voltage which is equivalent in cell number to the number of cells in the other identical numbered cell clusters.

Mowery, Kenneth D. (Noblesville, IN); Ripley, Eugene V. (Russiaville, IN)

2002-01-01T23:59:59.000Z

97

Wide-range voltage modulation  

SciTech Connect (OSTI)

The Superconducting Super Collider`s Medium Energy Booster Abort (MEBA) kicker modulator will supply a current pulse to the abort magnets which deflect the proton beam from the MEB ring into a designated beam stop. The abort kicker will be used extensively during testing of the Low Energy Booster (LEB) and the MEB rings. When the Collider is in full operation, the MEBA kicker modulator will abort the MEB beam in the event of a malfunction during the filling process. The modulator must generate a 14-{mu}s wide pulse with a rise time of less than 1 {mu}s, including the delay and jitter times. It must also be able to deliver a current pulse to the magnet proportional to the beam energy at any time during ramp-up of the accelerator. Tracking the beam energy, which increases from 12 GeV at injection to 200 GeV at extraction, requires the modulator to operate over a wide range of voltages (4 kV to 80 kV). A vacuum spark gap and a thyratron have been chosen for test and evaluation as candidate switches for the abort modulator. Modulator design, switching time delay, jitter and pre-fire data are presented.

Rust, K.R.; Wilson, J.M.

1992-06-01T23:59:59.000Z

98

PH-315 A. La Rosa VOLTAGE-CONTROLLED OSCILLATOR  

E-Print Network [OSTI]

PH-315 A. La Rosa VOLTAGE-CONTROLLED OSCILLATOR 1. PURPOSE: An integrator and a Schmitt Trigger voltage; hence its name "voltage-controlled oscillator." 2. VOLTAGE-CONTROLLED OSCILLATOR Figure 1 shows voltage. An unusual feature of the circuit is its operation using a single positive supply.1 #12;- + 50k V

99

Electro-optical voltage sensor head  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID)

1998-01-01T23:59:59.000Z

100

Researchers map atomic movements that trigger voltage fade in...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

map atomic movements that trigger voltage fade in high-energy-density batteries January 22, 2015 Voltage and capacity curves from an LMR-NMC high-energy cathode show voltage fade...

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Modular high voltage power supply for chemical analysis  

DOE Patents [OSTI]

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2008-07-15T23:59:59.000Z

102

Modular high voltage power supply for chemical analysis  

SciTech Connect (OSTI)

A high voltage power supply for use in a system such as a microfluidics system, uses a DC-DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC-DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2010-05-04T23:59:59.000Z

103

Modular high voltage power supply for chemical analysis  

DOE Patents [OSTI]

A high voltage power supply for use in a system such as a microfluidics system, uses a DC--DC converter in parallel with a voltage-controlled resistor. A feedback circuit provides a control signal for the DC--DC converter and voltage-controlled resistor so as to regulate the output voltage of the high voltage power supply, as well as, to sink or source current from the high voltage supply.

Stamps, James F. (Livermore, CA); Yee, Daniel D. (Dublin, CA)

2007-01-09T23:59:59.000Z

104

Electro-optic high voltage sensor  

DOE Patents [OSTI]

A small sized electro-optic voltage sensor capable of accurate measurement of high voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation. A polarization beam displacer separates the input beam into two beams with orthogonal linear polarizations and causes one linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels effect elliptically polarizes the beam as it travels through the crystal. A reflector redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization. The system may include a detector for converting the output beams into electrical signals and a signal processor for determining the voltage based on an analysis of the output beams.

Davidson, James R.; Seifert, Gary D.

2003-09-16T23:59:59.000Z

105

Voltage Management of Networks with Distributed Generation.   

E-Print Network [OSTI]

At present there is much debate about the impacts and benefits of increasing the amount of generation connected to the low voltage areas of the electricity distribution network. The UK government is under political ...

O'Donnell, James

2008-01-01T23:59:59.000Z

106

Low voltage arc formation in railguns  

DOE Patents [OSTI]

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, R.S.

1985-08-05T23:59:59.000Z

107

Low voltage arc formation in railguns  

DOE Patents [OSTI]

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile. 2 figs.

Hawke, R.S.

1987-11-17T23:59:59.000Z

108

Low voltage arc formation in railguns  

DOE Patents [OSTI]

A low voltage plasma arc is first established across the rails behind the projectile by switching a low voltage high current source across the rails to establish a plasma arc by vaporizing a fuse mounted on the back of the projectile, maintaining the voltage across the rails below the railgun breakdown voltage to prevent arc formation ahead of the projectile. After the plasma arc has been formed behind the projectile a discriminator switches the full energy bank across the rails to accelerate the projectile. A gas gun injector may be utilized to inject a projectile into the breech of a railgun. The invention permits the use of a gas gun or gun powder injector and an evacuated barrel without the risk of spurious arc formation in front of the projectile.

Hawke, Ronald S. (Livermore, CA)

1987-01-01T23:59:59.000Z

109

Group 3: Humidity, Temperature, and Voltage  

Broader source: Energy.gov [DOE]

This PowerPoint presentation, focused on humidity, temperature and voltage testing, was originally presented by John Wohlgemuth at the NREL 2013 PV Module Reliability Workshop on Feb. 26-27, 2013 in Denver, CO. It summarizes the activities of a working group chartered to develop accelerated stress tests that can be used as comparative predictors of module life versus stresses associated with humidity, temperature and voltage.

110

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2013 DOE...

111

Addressing the Voltage Fade Issue with Lithium-Manganese-Rich...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials Addressing the Voltage Fade Issue with Lithium-Manganese-Rich Oxide Cathode Materials 2012 DOE Hydrogen and...

112

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2012 DOE Hydrogen and Fuel Cells Program and...

113

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid...  

Broader source: Energy.gov (indexed) [DOE]

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...

114

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles...  

Broader source: Energy.gov (indexed) [DOE]

High-Voltage Solid Polymer Batteries for Electric Drive Vehicles High-Voltage Solid Polymer Batteries for Electric Drive Vehicles 2013 DOE Hydrogen and Fuel Cells Program and...

115

High voltage overhead long transmission line design and fault analysis.  

E-Print Network [OSTI]

??The goal of this project is to design a reliable high voltage overhead long transmission line that satisfies specific design criteria including voltage regulation, efficiency,… (more)

Elzain, Mohamed Ali

2011-01-01T23:59:59.000Z

116

Distribution System Voltage Performance Analysis for High-Penetration Photovoltaics  

SciTech Connect (OSTI)

This report examines the performance of commonly used distribution voltage regulation methods under reverse power flow.

Liu, E.; Bebic, J.

2008-02-01T23:59:59.000Z

117

A Charge Pump that Generates Negative High Voltage with Variable Voltage , Eugene Ivanova,  

E-Print Network [OSTI]

A Charge Pump that Generates Negative High Voltage with Variable Voltage Gain Jun Zhaob, , Eugene, Massachusetts 02115, U.S.A. Abstract A cross-coupled structure based charge pump that generates negative high. The proposed negative charge pump is designed to deliver 40 uA with a wide supply range from 2.5V to 5.5V using

Ayers, Joseph

118

Distributed Voltage and Current Control of Multi-Terminal High-Voltage Direct  

E-Print Network [OSTI]

}@kth.se.) Abstract: High-voltage direct current (HVDC) is a commonly used technology for long-distance power for multi-terminal HVDC (MTDC) systems is proposed. Under certain conditions on the controller gains factor behind long-distance power transmission. High-voltage direct current (HVDC) is a commonly used

Dimarogonas, Dimos

119

Electronic circuit for measuring series connected electrochemical cell voltages  

DOE Patents [OSTI]

An electronic circuit for measuring voltage signals in an energy storage device is disclosed. The electronic circuit includes a plurality of energy storage cells forming the energy storage device. A voltage divider circuit is connected to at least one of the energy storage cells. A current regulating circuit is provided for regulating the current through the voltage divider circuit. A voltage measurement node is associated with the voltage divider circuit for producing a voltage signal which is proportional to the voltage across the energy storage cell.

Ashtiani, Cyrus N. (West Bloomfield, MI); Stuart, Thomas A. (Toledo, OH)

2000-01-01T23:59:59.000Z

120

Experimental validation of a high voltage pulse measurement method.  

SciTech Connect (OSTI)

This report describes X-cut lithium niobate's (LiNbO3) utilization for voltage sensing by monitoring the acoustic wave propagation changes through LiNbO3 resulting from applied voltage. Direct current (DC), alternating current (AC) and pulsed voltage signals were applied to the crystal. Voltage induced shift in acoustic wave propagation time scaled quadratically for DC and AC voltages and linearly for pulsed voltages. The measured values ranged from 10 - 273 ps and 189 ps - 2 ns for DC and non-DC voltages, respectively. Data suggests LiNbO3 has a frequency sensitive response to voltage. If voltage source error is eliminated through physical modeling from the uncertainty budget, the sensor's U95 estimated combined uncertainty could decrease to ~0.025% for DC, AC, and pulsed voltage measurements.

Cular, Stefan; Patel, Nishant Bhupendra; Branch, Darren W.

2013-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Compact high voltage solid state switch  

DOE Patents [OSTI]

A compact, solid state, high voltage switch capable of high conduction current with a high rate of current risetime (high di/dt) that can be used to replace thyratrons in existing and new applications. The switch has multiple thyristors packaged in a single enclosure. Each thyristor has its own gate drive circuit that circuit obtains its energy from the energy that is being switched in the main circuit. The gate drives are triggered with a low voltage, low current pulse isolated by a small inexpensive transformer. The gate circuits can also be triggered with an optical signal, eliminating the trigger transformer altogether. This approach makes it easier to connect many thyristors in series to obtain the hold off voltages of greater than 80 kV.

Glidden, Steven C.

2003-09-23T23:59:59.000Z

122

SiGe BiCMOS Topologies for Low-Voltage Millimeter-Wave Voltage Controlled Oscillators and Frequency Dividers  

E-Print Network [OSTI]

SiGe BiCMOS Topologies for Low-Voltage Millimeter-Wave Voltage Controlled Oscillators and Frequency-mail: tod@eecg.toronto.edu Abstract -- BiCMOS topologies for mm-wave voltage- controlled oscillators operation for mm-wave applications. II. BICMOS VOLTAGE-CONTROLLED OSCILLATOR The Colpitts topology

Voinigescu, Sorin Petre

123

Physical simulation study of dynamic voltage instability  

SciTech Connect (OSTI)

This paper presents a physical simulation of the dynamic behavior of voltage instability in an interconnected multimachine environment. The dynamic evolving process leading to eventual voltage collapse, the scenario of the progressive reactive support reduction resulting from the MXL protection relays, the OLTC operation, and the effect of switched-in capacitor banks are examined using physical facilities in the laboratory. The physical simulation results are also compared with digital simulation results. This physical investigation provides a reliable foundation for the effective development of assessment approaches and countermeasures.

Tso, S.K.; Zhu, T.X. [Univ. of Hong Kong (Hong Kong); Zeng, Q.Y. [Electric Power Research Inst., Beijing (China); Lo, K.L. [Univ. of Strathclyde, Glasgow (United Kingdom). Dept. of Electrical and Electrical Engineering

1995-12-31T23:59:59.000Z

124

Electro-optic voltage sensor for sensing voltage in an E-field  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Idaho Falls, ID); Renak, Todd W. (Idaho Falls, ID)

1999-01-01T23:59:59.000Z

125

Electro-optic voltage sensor for sensing voltage in an E-field  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages is disclosed. The system employs a transmitter, a sensor disposed adjacent to but out of direct electrical contact with a conductor on which the voltage is to be measured, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor where the beam undergoes the Pockels electro-optic effect. The electro-optic effect causes phase shifting in the beam, which is in turn converted to a pair of independent beams, from which the voltage of a system based on its E-field is determined when the two beams are normalized by the signal processor. The sensor converts the beam by splitting the beam in accordance with the axes of the beam`s polarization state (an ellipse whose ellipticity varies between -1 and +1 in proportion to voltage) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured. 18 figs.

Woods, G.K.; Renak, T.W.

1999-04-06T23:59:59.000Z

126

Group 3: Humidity, Temperature and Voltage (Presentation)  

SciTech Connect (OSTI)

This is a summary of the work of Group 3 of the International PV QA Task Force. Group 3 is chartered to develop accelerated stress tests that can be used as comparative predictors of module lifetime versus stresses associated with humidity, temperature and voltage.

Wohlgemuth, J.

2013-09-01T23:59:59.000Z

127

Voltage control on a train system  

DOE Patents [OSTI]

The present invention provides methods for preventing low train voltages and managing interference, thereby improving the efficiency, reliability, and passenger comfort associated with commuter trains. An algorithm implementing neural network technology is used to predict low voltages before they occur. Once voltages are predicted, then multiple trains can be controlled to prevent low voltage events. Further, algorithms for managing inference are presented in the present invention. Different types of interference problems are addressed in the present invention such as "Interference During Acceleration", "Interference Near Station Stops", and "Interference During Delay Recovery." Managing such interference avoids unnecessary brake/acceleration cycles during acceleration, immediately before station stops, and after substantial delays. Algorithms are demonstrated to avoid oscillatory brake/acceleration cycles due to interference and to smooth the trajectories of closely following trains. This is achieved by maintaining sufficient following distances to avoid unnecessary braking/accelerating. These methods generate smooth train trajectories, making for a more comfortable ride, and improve train motor reliability by avoiding unnecessary mode-changes between propulsion and braking. These algorithms can also have a favorable impact on traction power system requirements and energy consumption.

Gordon, Susanna P.; Evans, John A.

2004-01-20T23:59:59.000Z

128

Electro-optic high voltage sensor  

DOE Patents [OSTI]

A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal having at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

Davidson, James R. (Idaho Falls, ID); Seifert, Gary D. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

129

Distribution System Voltage Regulation by Distributed Energy Resources  

SciTech Connect (OSTI)

This paper proposes a control method to regulate voltages in 3 phase unbalanced electrical distribution systems. A constrained optimization problem to minimize voltage deviations and maximize distributed energy resource (DER) active power output is solved by harmony search algorithm. IEEE 13 Bus Distribution Test System was modified to test three different cases: a) only voltage regulator controlled system b) only DER controlled system and c) both voltage regulator and DER controlled system. The simulation results show that systems with both voltage regulators and DER control provide better voltage profile.

Ceylan, Oguzhan [ORNL; Liu, Guodong [ORNL; Xu, Yan [ORNL; Tomsovic, Kevin [University of Tennessee, Knoxville (UTK)

2014-01-01T23:59:59.000Z

130

Multilevel Cascade H-bridge Inverter DC Voltage Estimation Through Output Voltage Sensing  

E-Print Network [OSTI]

system as the inverter power supply may vary. For example, interface of solar panels or fuel cell. The output voltage is then processed by a DSP unit that uses the signals that command the switches

Tolbert, Leon M.

131

Electrical system architecture having high voltage bus  

DOE Patents [OSTI]

An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

2011-03-22T23:59:59.000Z

132

Reactive Support and Voltage Control Service: Key Issues and Challenges  

E-Print Network [OSTI]

reactive support and voltage control services. Keywords ­ Competitive Electricity Markets, Reactive PowerReactive Support and Voltage Control Service: Key Issues and Challenges George Gross^, Paolo Marannino° and Gianfranco Chicco* ^ Department of Electrical and Computer Engineering, University

Gross, George

133

Low Voltage White Phosphorescent OLED Achievements  

Broader source: Energy.gov [DOE]

Universal Display Corporation (UDC) and its research partners at Princeton University and the University of Southern California have succeeded in developing a white phosphorescent OLED (PHOLED™) that achieved a record efficiency of 20 lumens per watt. This achievement is the result of the team's collaborative efforts to increase the efficiency of PHOLED lighting by focusing on two critical factors: lowering the drive voltages and increasing the amount of light extracted.

134

High Voltage Electrolyte for Lithium Batteries  

Broader source: Energy.gov (indexed) [DOE]

5.0E-04 1.0E-03 2 2.2 2.4 2.6 2.8 Voltage (V) dQdV (AhV) 1 st Charge 1.2M LiPF 6 ECEMC 37 1 st Charge 1.0M LiPF 6 TMS1NM3 55 with 2% and 4% VC 1 st Charge 1.0M LiPF 6 TMS...

135

Electro-optic voltage sensor head  

DOE Patents [OSTI]

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers.

Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Woods, Gregory K. (Cornelius, OR)

1999-01-01T23:59:59.000Z

136

Electro-optic voltage sensor head  

DOE Patents [OSTI]

The invention is an electro-optic voltage sensor head designed for integration with existing types of high voltage transmission and distribution apparatus. The sensor head contains a transducer, which comprises a transducing material in which the Pockels electro-optic effect is observed. In the practice of the invention at least one beam of electromagnetic radiation is routed into the transducing material of the transducer in the sensor head. The beam undergoes an electro-optic effect in the sensor head when the transducing material is subjected to an E-field. The electro-optic effect is observed as a differential phase a shift, also called differential phase modulation, of the beam components in orthogonal planes of the electromagnetic radiation. In the preferred embodiment the beam is routed through the transducer along an initial axis and then reflected by a retro-reflector back substantially parallel to the initial axis, making a double pass through the transducer for increased measurement sensitivity. The preferred embodiment of the sensor head also includes a polarization state rotator and at least one beam splitter for orienting the beam along major and minor axes and for splitting the beam components into two signals which are independent converse amplitude-modulated signals carrying E-field magnitude and hence voltage information from the sensor head by way of optic fibers. 6 figs.

Crawford, T.M.; Davidson, J.R.; Woods, G.K.

1999-08-17T23:59:59.000Z

137

Electrostatically screened, voltage-controlled electrostatic chuck  

DOE Patents [OSTI]

Employing an electrostatically screened, voltage-controlled electrostatic chuck particularly suited for holding wafers and masks in sub-atmospheric operations will significantly reduce the likelihood of contaminant deposition on the substrates. The electrostatic chuck includes (1) an insulator block having a outer perimeter and a planar surface adapted to support the substrate and comprising at least one electrode (typically a pair of electrodes that are embedded in the insulator block), (2) a source of voltage that is connected to the at least one electrode, (3) a support base to which the insulator block is attached, and (4) a primary electrostatic shield ring member that is positioned around the outer perimeter of the insulator block. The electrostatic chuck permits control of the voltage of the lithographic substrate; in addition, it provides electrostatic shielding of the stray electric fields issuing from the sides of the electrostatic chuck. The shielding effectively prevents electric fields from wrapping around to the upper or front surface of the substrate, thereby eliminating electrostatic particle deposition.

Klebanoff, Leonard Elliott (San Ramon, CA)

2001-01-01T23:59:59.000Z

138

Analysis and design of an electronic voltage ratchet  

E-Print Network [OSTI]

and decay. Impulse voltages are produced through the discharging of 0, capacitor into a shaping network consisting of resistors and a. capacitor as is shown in Figure 2. 9. The operation of the impulse generator is as follows. Capacitor Ci is charged from... voltage shaping network. as possible in order to reduce oscillations in the wavefront and wavetail portions of the impulse voltage [1). The impulse voltage generator requires a, highly charged capacitor or bank of capacitors. Capacitors may be charged...

Menendez, Jorge Carlos

2012-06-07T23:59:59.000Z

139

Selective compensation of voltage harmonics in grid-connected microgrids  

E-Print Network [OSTI]

1 Selective compensation of voltage harmonics in grid-connected microgrids Mehdi Savaghebia , Juan is proposed for selective compensation of main voltage harmonics in a grid- connected microgrid. The aim level. Keywords Distributed Generator (DG); microgrid; grid-connected; voltage harmonics compensation. 1

Vasquez, Juan Carlos

140

Structural Optimization of High Voltage Transmission Line Towers considering  

E-Print Network [OSTI]

Structural Optimization of High Voltage Transmission Line Towers considering Continuum and Discrete/or to common designs largely repeated (e.g. automotive compo- nents), and high voltage transmission towers can than conventional designs of high voltage transmission line towers. The optimization model proposed

Colominas, Ignasi

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

LM2907LM2917FrequencytoVoltageConverter February 1995  

E-Print Network [OSTI]

TL H 7942 LM2907LM2917FrequencytoVoltageConverter February 1995 LM2907 LM2917 Frequency to Voltage Converter General Description The LM2907 LM2917 series are monolithic frequency to voltage converters doubling for low ripple full input protection in two versions (LM2907-8 LM2917-8) and its output swings

Wedeward, Kevin

142

Characterized ideal LC circuit Charge, current and voltage vary sinusoidally  

E-Print Network [OSTI]

resistance to LC circuit Oscillations become damped Charge, current and voltage still vary sinusoidally Oscillations Draw phasors for voltages of R, C and L at same time t Orient VR, VL, & VC phasors relativeReview Characterized ideal LC circuit Charge, current and voltage vary sinusoidally Added

Bertulani, Carlos A. - Department of Physics and Astronomy, Texas A&M University

143

Accurately measuring current-voltage characteristics of tunnel diodes  

E-Print Network [OSTI]

of the bias voltage range of oscillations in the I–V curve.and the bias voltage range of oscillation in the I–V curve.or to know the exact voltage range of oscillation in the I–V

Bao, Mingqiang; Wang, Kang L

2006-01-01T23:59:59.000Z

144

DCS1800/WCDMA ADAPTIVE VOLTAGE-CONTROLLED OSCILLATOR  

E-Print Network [OSTI]

DCS1800/WCDMA ADAPTIVE VOLTAGE-CONTROLLED OSCILLATOR Aleksandar Tasiü, Wouter A. Serdijn and John R, an adaptive 2G/3G voltage-controlled oscillator (VCO) is described in this paper. For the DCS1800 operation with this reasoning, an adaptive 2G/3G voltage- controlled oscillator, meant for a dual-standard adaptive front

Serdijn, Wouter A.

145

System for increasing corona inception voltage of insulating oils  

DOE Patents [OSTI]

The Corona Inception Voltage of insulating oils is increased by repetitive cycles of prestressing the oil with a voltage greater than the corona inception voltage, and either simultaneously or serially removing byproducts of corona by evacuation and heating the oil. 5 figs.

Rohwein, G.J.

1998-05-19T23:59:59.000Z

146

Combination & Integration of DPF-SCR Aftertreatment  

Broader source: Energy.gov (indexed) [DOE]

for HDD to provide a pathway to the next generation of emissions control systems CRADA with PACCAR, working closely with DAF Trucks Highly evolving field of work (mostly...

147

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided into high voltage  

E-Print Network [OSTI]

Voltage-dependent calcium channels and currents in native neurons and other cells have been divided than one subtype of channel. A new subfamily of voltage-dependent calcium channel á1 subunit genes. 1999), having four domains, each with a voltage sensor and a pore-forming P loop. However

Dolphin, Annette C.

148

A new space vector PWM control strategy for high performance converters  

E-Print Network [OSTI]

high quality output voltage. DC to AC inverter system with proposed modulator achieves DC link voltage ripple immunity and maintain low Total Harmonic Distortion (THD) specification across the terminals of a nonlinear load....

Xie, Bin

1993-01-01T23:59:59.000Z

149

Method of Controlling Corona Effects and Breakdown Voltage of Small Air Gaps Stressed by Impulse Voltages  

E-Print Network [OSTI]

This paper investigates the influence of a resistor on the dielectric behavior of an air gap. The resistor is connected in series with the air gap and the latter is stressed by impulse voltage. Air gap arrangements of different geometry with either the rod or the plate grounded are stressed with impulse voltages of both positive and negative polarity. The resistor is connected in series with the air gap in the return circuit connecting the gap with the impulse generator. The method followed involves the investigation of the graphs of the charging time concerning the air gaps capacitances, in connection to the value of the resistor, the geometry of the gap, the effect of grounding and the polarity effect. It is determined that the charging time of the air gap increases, as the value of the resistor increases. It is also determined that the peak voltage value of the fully charged air gap decreases as the value of the resistor increases. The results of the mathematical and simulation analysis are compared with the results of the oscillograms taken from experimental work. In addition and consequently to the above results it is concluded from the experimental work that the in series connection of the resistor in the circuit has significant influence on corona pulses (partial discharges) occurring in the gap and on the breakdown voltage of the gap. A new method of controlling the corona effects and consequently the breakdown voltage of small air gaps stressed by impulse voltage of short duration in connection to the ground effect and the polarity effect has arisen. Furthermore through mathematical analysis of the charging graphs obtained from simulation and experimental oscillograms there was a calculation of the values of the capacitance of the air gaps in relation to their geometry and the results were compared to the values calculated with mathematical analysis.

Athanasios Maglaras; Trifon Kousiouris; Frangiskos Topalis; Dimitrios Katsaros; Leandros A. Maglaras; Konstantina Giannakopoulou

2014-10-15T23:59:59.000Z

150

Transient recovery voltage considerations in the application of medium voltage circuit breakers  

SciTech Connect (OSTI)

Medium Voltage Circuit Breakers can fail to interrupt 3-phase fault currents when power systems have Transient Recovery Voltage (TRV) characteristics which exceed the rating of the circuit breaker. This paper examines the application of 13.8kV generation and load switchgear for an oil refinery in which circuit parameters as originally designed would have exceeded the 13.8kV circuit breakers TRV ratings had corrective measures not been taken. This paper illustrates this case and discusses the basis of TRV, how TRV is assessed, and alternative actions taken to bring circuits to within the 13.8 kV circuit breaker ratings.

Swindler, D.L.; Schwartz, P.; Hamer, P.S.; Lambert, S.R.

1995-12-31T23:59:59.000Z

151

Safe epoxy encapsulant for high voltage magnetics  

SciTech Connect (OSTI)

This paper describes the use of Formula 456, an aliphatic amine cured epoxy for impregnating coils and high voltage transformers. Sandia has evaluated a number of MDA-free epoxy encapsulants which relied on either anhydride or other aromatic amine curing agents. The use of aliphatic amine curing agents was more recently evaluated and has resulted in the definition of Formula 456 resin. Methylene dianiline (MDA) has been used for more than 20 years as the curing agent for various epoxy formulations throughout the Department of Energy and much of industry. Sandia National Laboratories began the process of replacing MDA with other formulations because of regulations imposed by OSHA on the use of MDA. OSHA has regulated MDA because it is a suspect carcinogen. Typically the elimination of OSHA-regulated materials provides a rare opportunity to qualify new formulations in a range of demanding applications. It was important to take full advantage of that opportunity, although the associated materials qualification effort was costly. Small high voltage transformers are one of those demanding applications. The successful implementation of the new formulation for high reliability transformers will be described. The test results that demonstrate the parts are qualified for use in DOE weapon systems will be presented.

Sanchez, R.O.; Archer, W.E.

1998-01-01T23:59:59.000Z

152

Design and applications of a flicker voltage generator  

SciTech Connect (OSTI)

In this paper, a 200W flicker voltage generator is made by using microcomputers and linear amplification circuits. The modulation amplitudes and frequencies based on the UIE {Delta}V{sub 10} evaluation can be arbitrarily assigned by software with high accuracy. The flicker voltage signals measured at the customer side also can be re-generated. Some applications, such as evaluating the effects of flicker voltage on incandescent and compact fluorescent lamps (CFLs), are also made. From experimental tests by use of the flicker voltage generator, the properties of some compact fluorescent lamps and incandescent lamps are compared. Those properties describe the relation between input voltage variation and output flux of lamps, such that there is direct description of influences of flicker voltages on lamps.

Chang, W.N.; Wu, C.J. [National Taiwan Inst. of Tech., Peitow-Taipei (Taiwan, Province of China). Dept. of Electrical Engineering

1995-12-31T23:59:59.000Z

153

Sequential circuit design for radiation hardened multiple voltage integrated circuits  

DOE Patents [OSTI]

The present invention includes a radiation hardened sequential circuit, such as a bistable circuit, flip-flop or other suitable design that presents substantial immunity to ionizing radiation while simultaneously maintaining a low operating voltage. In one embodiment, the circuit includes a plurality of logic elements that operate on relatively low voltage, and a master and slave latches each having storage elements that operate on a relatively high voltage.

Clark, Lawrence T. (Phoenix, AZ); McIver, III, John K. (Albuquerque, NM)

2009-11-24T23:59:59.000Z

154

Voltage controlled MESFET pulse shape generator  

SciTech Connect (OSTI)

A programmable pulse shape generator capable of producing pulse shapes for Nova and Beamlet has been designed and simulated using the circuit code SPICE. The design utilizes power MESFETS, which are commonly used in microwave amplifiers. The pulse shape is varied by setting a bias voltage on each in a chain of MESFETS with a 200 ps temporal resolution. The electrical pulse then drives an integrated electro-optic modulator similar to what is on Beamlet. Pulse shapes 22 and 25, used on Nova, have been generated by this design. There is no fundamental barrier to making such a pulse generator for use on the National Ignition Facility. In fact, the longer time scales on the NIF pulse will ease the high speed requirements of the pulse shape generator allowing the use of less expensive components. The next step will be to build a prototype circuit for initial testing on Beamlet and Nova.

Burkhart, S.C.

1994-10-26T23:59:59.000Z

155

Method for voltage-gated protein fractionation  

DOE Patents [OSTI]

We report unique findings on the voltage dependence of protein exclusion from the pores of nanoporous polymer exclusion membranes. The pores are small enough that proteins are excluded from passage with low applied electric fields, but increasing the field enables proteins to pass through. The requisite field necessary for a change in exclusion is protein-specific with a correlation to protein size. The field-dependence of exclusion is important to consider for preconcentration applications. The ability to selectively gate proteins at exclusion membranes is also a promising means for manipulating and characterizing proteins. We show that field-gated exclusion can be used to selectively remove proteins from a mixture, or to selectively trap protein at one exclusion membrane in a series.

Hatch, Anson (Tracy, CA); Singh, Anup K. (Danville, CA)

2012-04-24T23:59:59.000Z

156

Electrochemical Characterization of Voltage Fade in LMR-NMC cells  

Broader source: Energy.gov (indexed) [DOE]

the extent of Voltage Fade December 2012 * Establish baseline data on standard materials to facilitate comparison of various datasets March 2013 * Obtain data to determine...

157

High Temperature, High Voltage Fully Integrated Gate Driver Circuit  

Broader source: Energy.gov (indexed) [DOE]

driver circuit, 5-V on- chip voltage regulator, short-circuit protection, undervoltage lockout, bootstrap capacitor, dead time controller and temperature sensor * 0.8-micron,...

158

Vehicle Technologies Office Merit Review 2014: Voltage Fade,...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Voltage Fade, an ABR Deep Dive Project: Status and Outcomes Presentation given by Argonne National Laboratory at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle...

159

Nanoscale Morphological and Chemical Changes of High Voltage...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Nanoscale Morphological and Chemical Changes of High Voltage Lithium-Manganese Rich NMC Composite Cathodes with Cycling Friday, August 29, 2014 Renewable energy is critical for the...

160

active capacitive voltage: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Khoman 5 Discrete Steps in the Capacitance-Voltage Characteristics of GaInNGaN Light Emitting Diode Structures Materials Science Websites Summary: Discrete Steps in the...

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

High Voltage Electrolytes for Li-ion Batteries  

Broader source: Energy.gov (indexed) [DOE]

or otherwise restricted information High Voltage Electrolytes for Li-ion Batteries Vehicle Technologies Program 2 Overview * Start: Sep 2008 * End: Sep 2011 * 20 %...

162

Electrochemical Characterization of Voltage Fade in LMR-NMC cells...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Electrochemical Characterization of Voltage Fade in LMR-NMC cells 2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer...

163

Triple voltage dc-to-dc converter and method  

DOE Patents [OSTI]

A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

Su, Gui-Jia (Knoxville, TN)

2008-08-05T23:59:59.000Z

164

Local Dynamic Reactive Power for Correction of System Voltage Problems  

SciTech Connect (OSTI)

Distribution systems are experiencing outages due to a phenomenon known as local voltage collapse. Local voltage collapse is occurring in part because modern air conditioner compressor motors are much more susceptible to stalling during a voltage dip than older motors. These motors can stall in less than 3 cycles (.05s) when a fault, such as on the sub-transmission system, causes voltage to sag to 70 to 60%. The reasons for this susceptibility are discussed in the report. During the local voltage collapse, voltages are depressed for a period of perhaps one or two minutes. There is a concern that these local events are interacting together over larger areas and may present a challenge to system reliability. An effective method of preventing local voltage collapse is the use of voltage regulation from Distributed Energy Resources (DER) that can supply or absorb reactive power. DER, when properly controlled, can provide a rapid correction to voltage dips and prevent motor stall. This report discusses the phenomenon and causes of local voltage collapse as well as the control methodology we have developed to counter voltage sag. The problem is growing because of the use of low inertia, high efficiency air conditioner (A/C) compressor motors and because the use of electric A/C is growing in use and becoming a larger percentage of system load. A method for local dynamic voltage regulation is discussed which uses reactive power injection or absorption from local DER. This method is independent, rapid, and will not interfere with conventional utility system voltage control. The results of simulations of this method are provided. The method has also been tested at the ORNL s Distributed Energy Communications and Control (DECC) Laboratory using our research inverter and synchronous condenser. These systems at the DECC Lab are interconnected to an actual distribution system, the ORNL distribution system, which is fed from TVA s 161kV sub-transmission backbone. The test results are also provided and discussed. The simulations and testing show that local voltage control from DER can prevent local voltage collapse. The results also show that the control can be provided so quickly, within 0.5 seconds, that is does not interfere with conventional utility methods.

Kueck, John D [ORNL; Rizy, D Tom [ORNL; Li, Fangxing [ORNL; Xu, Yan [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Adhikari, Sarina [ORNL; Irminger, Philip [ORNL

2008-12-01T23:59:59.000Z

165

Measurement of high voltage using Rutherford backscattering spectrometry  

E-Print Network [OSTI]

A novel variation of Rutherford Backscattering Spectrometry (RBS) has been utilized to measure a high voltage collected on an aluminum target by Direct Energy Conversion. The maximum high voltage on the target was measured to be 97.5 kV +/- 2 k...

Abrego, Celestino Pete

2007-04-25T23:59:59.000Z

166

A LOW-VOLTAGE TEMPERATURE-STABLE MICROMECHANICAL PIEZOELECTRIC OSCILLATOR  

E-Print Network [OSTI]

A LOW-VOLTAGE TEMPERATURE-STABLE MICROMECHANICAL PIEZOELECTRIC OSCILLATOR Reza Abdolvand, Hossein polarization voltages (5-20V) for operation, which complicates the design of the oscillator circuit in today reference oscillator that utilizes a temperature-stable thin- film piezoelectric-on-silicon resonator

Ayazi, Farrokh

167

REFINED RFP LOOP VOLTAGE CALCULATION J.C. Sprott  

E-Print Network [OSTI]

is the stored magnetic energy, Up is the plasma energy, and 'E is the global energy confinement time, which-of-merit for RFP devices is the loop voltage. Low loop voltage implies high plasma temperature and long energy is smallest if the loop is as close to the outside of the shell and as far from the primary windings

Sprott, Julien Clinton

168

LOW VOLTAGE ANALOG CIRCUITS USING STANDARD CMOS TECHNOLOGY  

E-Print Network [OSTI]

LOW VOLTAGE ANALOG CIRCUITS USING STANDARD CMOS TECHNOLOGY Phillip E. Allen, Benjamin J. Blalock, and Gabriel A. Rincon School of Electrical and Computer Engineering Georgia Institute of Technology Atlanta supply voltages in CMOS integrated circuits. As the channel lengths of CMOS technology decrease

Rincon-Mora, Gabriel A.

169

Power Grid Voltage Integrity Verification Department of ECE  

E-Print Network [OSTI]

Power Grid Voltage Integrity Verification Maha Nizam Department of ECE University of Toronto devgan@magma-da.com ABSTRACT Full-chip verification requires one to check if the power grid is safe, i.e., if the voltage drop on the grid does not exceed a cer- tain threshold. The traditional simulation-based solution

Najm, Farid N.

170

Living and Working Safely Around High-Voltage Power Lines.  

SciTech Connect (OSTI)

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

United States. Bonneville Power Administration.

2001-06-01T23:59:59.000Z

171

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage put under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1996-01-01T23:59:59.000Z

172

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 figs.

Shimer, D.W.; Lange, A.C.

1996-10-15T23:59:59.000Z

173

Spark-safe low-voltage detonator  

DOE Patents [OSTI]

A column of explosive in a low-voltage detonator which makes it spark-safe ncludes an organic secondary explosive charge of HMX in the form of a thin pad disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to an electrical ignition device at one end of the bore. The pad of secondary charge has an axial thickness within the range of twenty to thirty percent of its diameter. The explosive column also includes a first explosive charge of CP disposed in the housing bore in the ignition region of the explosive column next to the secondary charge pad on a side opposite from the ignition device. The first CP charge is loaded under sufficient pressure, 25 to 40 kpsi, to provide mechanical confinement of the pad of secondary charge and physical coupling thereof with the ignition device. The explosive column further includes a second explosive charge of CP disposed in the housing bore in a transition region of the explosive column next to the first CP charge on a side opposite from the pad of secondary charge. The second CP charge is loaded under sufficient pressure, about 10 kpsi, to allow occurrence of DDT. The first explosive CP charge has an axial thickness within the range of twenty to thirty percent of its diameter, whereas the second explosive CP charge contains a series of increments (nominally 4) each of which has an axial thickness-to-diameter ratio of one to two.

Lieberman, Morton L. (Albuquerque, NM)

1989-01-01T23:59:59.000Z

174

Bonfire-safe low-voltage detonator  

DOE Patents [OSTI]

A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half.

Lieberman, Morton L. (Albuquerque, NM)

1990-01-01T23:59:59.000Z

175

Bonfire-safe low-voltage detonator  

DOE Patents [OSTI]

A column of explosive in a low-voltage detonator which makes it bonfire-safe includes a first layer of an explosive charge of CP, or a primary explosive, and a second layer of a secondary organic explosive charge, such as PETN, which has a degradation temperature lower than the autoignition temperature of the CP or primary explosives. The first layer is composed of a pair of increments disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to and in contact with an electrical ignition device at one end of the bore. The second layer is composed of a plurality of increments disposed in the housing bore in a transition region of the explosive column next to and in contact with the first layer on a side opposite from the ignition device. The first layer is loaded under a sufficient high pressure, 25 to 40 kpsi, to achieve ignition, whereas the second layer is loaded under a sufficient low pressure, about 10 kpsi, to allow occurrence of DDT. Each increment of the first and second layers has an axial length-to-diameter ratio of one-half. 2 figs.

Lieberman, M.L.

1988-07-01T23:59:59.000Z

176

High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

Shimer, D.W.; Lange, A.C.

1995-05-23T23:59:59.000Z

177

High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents [OSTI]

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1995-01-01T23:59:59.000Z

178

Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis  

E-Print Network [OSTI]

Panel Session: Optimization Techniques in Voltage Collapse Analysis," IEEE PES Summer Meeting, San Diego, July 14, 1998. Applications of Optimization to Voltage Collapse Analysis Claudio A. Ca|Thispaper describesseveralapplica- tions of optimization for voltage stability analysis VSA of power systems. Voltage stability prob

Cañizares, Claudio A.

179

Spark-safe low-voltage detonator  

DOE Patents [OSTI]

A column of explosive in a low-voltage detonator which makes it spark-safe includes an organic secondary explosive charge of HMX in the form of a thin pad disposed in a bore of a housing of the detonator in an ignition region of the explosive column and adjacent to an electrical ignition device at one end of the bore. The pad of secondary charge has an axial thickness within the range of twenty to thirty percent of its diameter. The explosive column also includes a first explosive charge of CP disposed in the housing bore in the ignition region of the explosive column next to the secondary charge pad on a side opposite from the ignition device. The first CP charge is loaded under sufficient pressure, 25 to 40 kpsi, to provide mechanical confinement of the pad of secondary charge and physical coupling thereof with the ignition device. The explosive column further includes a second explosive charge of CP disposed in the housing bore in a transition region of the explosive column next to the first CP charge on a side opposite from the pad of secondary charge. The second CP charge is loaded under sufficient pressure, about 10 kpsi, to allow occurrence of DDT. The first explosive CP charge has an axial thickness within the range of twenty to thirty percent of its diameter, whereas the second explosive CP charge contains a series of increments (nominally 4), each of which has an axial thickness-to-diameter ratio of one to two. 2 figs.

Lieberman, M.L.

1988-07-01T23:59:59.000Z

180

Electro-optic voltage sensor with Multiple Beam Splitting  

DOE Patents [OSTI]

A miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID)

2000-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Electro-optic voltage sensor with beam splitting  

DOE Patents [OSTI]

The invention is a miniature electro-optic voltage sensor system capable of accurate operation at high voltages without use of the dedicated voltage dividing hardware typically found in the prior art. The invention achieves voltage measurement without significant error contributions from neighboring conductors or environmental perturbations. The invention employs a transmitter, a sensor, a detector, and a signal processor. The transmitter produces a beam of electromagnetic radiation which is routed into the sensor. Within the sensor the beam undergoes the Pockels electro-optic effect. The electro-optic effect produces a modulation of the beam's polarization, which is in turn converted to a pair of independent conversely-amplitude-modulated signals, from which the voltage of the E-field is determined by the signal processor. The use of converse AM signals enables the signal processor to better distinguish signal from noise. The sensor converts the beam by splitting the beam in accordance with the axes of the beam's polarization state (an ellipse) into at least two AM signals. These AM signals are fed into a signal processor and processed to determine the voltage between a ground conductor and the conductor on which voltage is being measured.

Woods, Gregory K. (Cornelius, OR); Renak, Todd W. (Idaho Falls, ID); Davidson, James R. (Idaho Falls, ID); Crawford, Thomas M. (Idaho Falls, ID)

2002-01-01T23:59:59.000Z

182

Optically triggered high voltage switch network and method for switching a high voltage  

DOE Patents [OSTI]

An optically triggered solid state switch and method for switching a high voltage electrical current. A plurality of solid state switches (350) are connected in series for controlling electrical current flow between a compensation capacitor (112) and ground in a reactive power compensator (50, 50') that monitors the voltage and current flowing through each of three distribution lines (52a, 52b and 52c), which are supplying three-phase power to one or more inductive loads. An optical transmitter (100) controlled by the reactive power compensation system produces light pulses that are conveyed over optical fibers (102) to a switch driver (110') that includes a plurality of series connected optical triger circuits (288). Each of the optical trigger circuits controls a pair of the solid state switches and includes a plurality of series connected resistors (294, 326, 330, and 334) that equalize or balance the potential across the plurality of trigger circuits. The trigger circuits are connected to one of the distribution lines through a trigger capacitor (340). In each switch driver, the light signals activate a phototransistor (300) so that an electrical current flows from one of the energy reservoir capacitors through a pulse transformer (306) in the trigger circuit, producing gate signals that turn on the pair of serially connected solid state switches (350).

El-Sharkawi, Mohamed A. (Renton, WA); Andexler, George (Everett, WA); Silberkleit, Lee I. (Mountlake Terrace, WA)

1993-01-19T23:59:59.000Z

183

A capacitor-less low drop-out voltage regulator with fast transient response  

E-Print Network [OSTI]

. Most systems incorporate several voltage regulators which supply various subsystems and provide isolation among such subsystems. Low dropout (LDO) voltage regulators are generally used to supply low voltage, low noise analog circuitry. Each LDO...

Milliken, Robert Jon

2006-04-12T23:59:59.000Z

184

A Comparison of High-Voltage Switches  

SciTech Connect (OSTI)

This report summarizes our work on high-voltage switches during the past few years. With joint funding from the Department of Energy (DOE) and the Department of Defense (DOD), we tested a wide variety of switches to a common standard. This approach permitted meaningful comparisons between disparate switches. Most switches were purchased from commercial sources, though some were experimental devices. For the purposes of this report, we divided the switches into three generic types (gas, vacuum, and semiconductor) and selected data that best illustrates important strengths and weaknesses of each switch type. Test techniques that indicate the state of health of the switches are emphasized. For example, a good indicator of residual gas in a vacuum switch is the systematic variation of the switching delay in response to changes in temperature and/or operating conditions. We believe that the presentation of this kind of information will help engineers to select and to test switches for their particular applications. Our work was limited to switches capable of driving slappers. Also known as exploding-foil initiators, slappers are detonators that initiate a secondary explosive by direct impact with a small piece of matter moving at the detonation velocity (several thousands of meters per second). A slapper is desirable for enhanced safety (no primary explosive), but it also places extra demands on the capacitor-discharge circuit to deliver a fast-rising current pulse (greater than 10 A/ns) of several thousand amperes. The required energy is substantially less than one joule; but this energy is delivered in less than one microsecond, taking the peak power into the megawatt regime. In our study, the switches operated in the 1 kV to 3 kV range and were physically small, roughly 1 cm{sup 3} or less. Although a fuze functions only once in actual use, multiple-shot capability is important for production testing and for research work. For this reason, we restricted this report to multiple-shot switches. Furthermore, our work included only switches with submicrosecond timing precision, thereby excluding mechanical switches.

Chu, K.W.; Scott, G.L.

1999-02-01T23:59:59.000Z

185

Multilevel cascade voltage source inverter with seperate DC sources  

DOE Patents [OSTI]

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

Peng, Fang Zheng (Oak Ridge, TN); Lai, Jih-Sheng (Knoxville, TN)

1997-01-01T23:59:59.000Z

186

Multilevel cascade voltage source inverter with separate DC sources  

DOE Patents [OSTI]

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations. 15 figs.

Peng, F.Z.; Lai, J.S.

1997-06-24T23:59:59.000Z

187

Unravelling the Performance Degradation Mechanisms in High-voltage...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Unravelling the Performance Degradation Mechanisms in High-voltage Lithium-ion Battery Composite Oxide Electrodes Apr 11 2014 02:00 PM - 03:00 PM Debasish Mohanty, ORNL, Oak Ridge...

188

Stability issues in IC Low Drop Out voltage regulators  

E-Print Network [OSTI]

Performance issues of IC Low Drop Out (LDO) voltage regulators, with specific reference to stability, are discussed in this thesis. Evaluation of existing frequency compensation schemes and their performances across operating loads is presented...

Chava, Krishna Chaitanya

2002-01-01T23:59:59.000Z

189

Operation of buck regulator with ultra-low input voltage  

E-Print Network [OSTI]

Based on the LTC3621 and LTC3624, the designed buck regulator proposed in this thesis aims to lower the allowed input voltage and increase efficiency compared to the original part without making significant changes to ...

Harris, Cory Angelo

2014-01-01T23:59:59.000Z

190

Voltage Dependent Charge Storage Modes and Capacity in Subnanometer Pores  

SciTech Connect (OSTI)

Using molecular dynamics simulations, we show that charge storage in subnanometer pores follows a distinct voltage-dependent behavior. Specifically, at lower voltages, charge storage is achieved by swapping co-ions in the pore with counterions in the bulk electrolyte. As voltage increases, further charge storage is due mainly to the removal of co-ions from the pore, leading to a capacitance increase. The capacitance eventually reaches a maximum when all co-ions are expelled from the pore. At even higher electrode voltages, additional charge storage is realized by counterion insertion into the pore, accompanied by a reduction of capacitance. The molecular mechanisms of these observations are elucidated and provide useful insight for optimizing energy storage based on supercapacitors.

Qiao, Rui [Clemson University; Meunier, V. [Rensselaer Polytechnic Institute (RPI); Huang, Jingsong [ORNL; Wu, Peng [ORNL; Sumpter, Bobby G [ORNL

2012-01-01T23:59:59.000Z

191

An Adaptive Voltage Control Algorithm with Multiple Distributed Energy  

SciTech Connect (OSTI)

Distributed energy resources (DE) with power electronics (PE) interfaces with the right control are capable of providing reactive power related ancillary services. Voltage regulation in particular has drawn much attention. In this paper the challenges to control multiple DEs to regulate the local voltage in distribution systems is addressed and a decentralized adaptive voltage control method is proposed. The simulation results in different system conditions show that this adaptive voltage control method is capable of satisfying the fast response speed requirement without causing oscillation or instability of the system. Since this method has high tolerance to the shortage of the system parameters and can be widely adaptive to the variable operation situations of the power systems, it is very suited for the utility application.

Li, Huijuan [University of Tennessee, Knoxville (UTK); Li, Fangxing [ORNL; Adhikari, Sarina [ORNL; Xu, Yan [ORNL; Rizy, D Tom [ORNL; Kueck, John D [ORNL

2009-01-01T23:59:59.000Z

192

Modeling the operating voltage of liquid metal battery cells  

E-Print Network [OSTI]

A one-dimensional, integrative model of the voltage during liquid metal battery operation has been developed to enhance the understanding of performance at the cell level. Two liquid metal batteries were studied: Mg-Sb for ...

Newhouse, Jocelyn Marie

2014-01-01T23:59:59.000Z

193

Multilevel cascade voltage source inverter with seperate DC sources  

DOE Patents [OSTI]

A multilevel cascade voltage source inverter having separate DC sources is described herein. This inverter is applicable to high voltage, high power applications such as flexible AC transmission systems (FACTS) including static VAR generation (SVG), power line conditioning, series compensation, phase shifting and voltage balancing and fuel cell and photovoltaic utility interface systems. The M-level inverter consists of at least one phase wherein each phase has a plurality of full bridge inverters equipped with an independent DC source. This inverter develops a near sinusoidal approximation voltage waveform with only one switching per cycle as the number of levels, M, is increased. The inverter may have either single-phase or multi-phase embodiments connected in either wye or delta configurations.

Peng, Fang Zheng (Knoxville, TN); Lai, Jih-Sheng (Blacksburg, VA)

2002-01-01T23:59:59.000Z

194

High frequency AC power converter for low voltage circuits  

E-Print Network [OSTI]

This thesis presents a novel AC power delivery architecture that is suitable for VHF frequency (50-100MHz) polyphase AC/DC power conversion in low voltage integrated circuits. A complete AC power delivery architecture was ...

Salazar, Nathaniel Jay Tobias

2012-01-01T23:59:59.000Z

195

Planar LTCC transformers for high voltage flyback converters: Part II.  

SciTech Connect (OSTI)

This paper is a continuation of the work presented in SAND2007-2591 'Planar LTCC Transformers for High Voltage Flyback Converters'. The designs in that SAND report were all based on a ferrite tape/dielectric paste system originally developed by NASCENTechnoloy, Inc, who collaborated in the design and manufacturing of the planar LTCC flyback converters. The output/volume requirements were targeted to DoD application for hard target/mini fuzing at around 1500 V for reasonable primary peak currents. High voltages could be obtained but with considerable higher current. Work had begun on higher voltage systems and is where this report begins. Limits in material properties and processing capabilities show that the state-of-the-art has limited our practical output voltage from such a small part volume. In other words, the technology is currently limited within the allowable funding and interest.

Schofield, Daryl (NASCENTechnology, Inc., Watertown, SD); Schare, Joshua M., Ph.D.; Slama, George (NASCENTechnology, Inc., Watertown, SD); Abel, David (NASCENTechnology, Inc., Watertown, SD)

2009-02-01T23:59:59.000Z

196

Secondary Control for Voltage Unbalance Compensation in an Islanded Microgrid  

E-Print Network [OSTI]

coupling (PCC). Unbalance compensation is achieved by proper control of distributed generators (DGs unbalance. Keywords-distributed generation; microgrid; secondary control; voltage unbalance compensation I. INTRODUCTION Distributed Generators (DGs) may be connected individually to the utility grid or be integrated

Vasquez, Juan Carlos

197

IMPACT OF DYNAMIC VOLTAGE SCALING (DVS) ON CIRCUIT OPTIMIZATION  

E-Print Network [OSTI]

Circuit designers perform optimization procedures targeting speed and power during the design of a circuit. Gate sizing can be applied to optimize for speed, while Dual-VT and Dynamic Voltage Scaling (DVS) can be applied to optimize for leakage...

Esquit Hernandez, Carlos A.

2010-01-16T23:59:59.000Z

198

Design & Fabrication of a High-Voltage Photovoltaic Cell  

SciTech Connect (OSTI)

Silicon photovoltaic (PV) cells are alternative energy sources that are important in sustainable power generation. Currently, applications of PV cells are limited by the low output voltage and somewhat low efficiency of such devices. In light of this fact, this project investigates the possibility of fabricating high-voltage PV cells on float-zone silicon wafers having output voltages ranging from 50 V to 2000 V. Three designs with different geometries of diffusion layers were simulated and compared in terms of metal coverage, recombination, built-in potential, and conduction current density. One design was then chosen and optimized to be implemented in the final device design. The results of the simulation serve as a feasibility test for the design concept and provide supportive evidence of the effectiveness of silicon PV cells as high-voltage power supplies.

Felder, Jennifer; /North Carolina State U. /SLAC

2012-09-05T23:59:59.000Z

199

High-voltage air-core pulse transformers  

SciTech Connect (OSTI)

General types of air core pulse transformers designed for high voltage pulse generation and energy transfer applications are discussed with special emphasis on pulse charging systems which operate up to the multi-megavolt range. The design, operation, dielectric materials, and performance are described. It is concluded that high voltage air core pulse transformers are best suited to applications outside the normal ranges of conventional magnetic core transformers. In general these include charge transfer at high power levels and fast pulse generation with comparatively low energy. When properly designed and constructed, they are capable of delivering high energy transfer efficiency and have demonstrated superior high voltage endurance. The principal disadvantage of high voltage air core transformers is that they are not generally available from commercial sources. Consequently, the potential user must become thoroughly familiar with all aspects of design, fabrication and system application before he can produce a high performance transformer system. (LCL)

Rohwein, G. J.

1981-01-01T23:59:59.000Z

200

Time varying voltage combustion control and diagnostics sensor  

DOE Patents [OSTI]

A time-varying voltage is applied to an electrode, or a pair of electrodes, of a sensor installed in a fuel nozzle disposed adjacent the combustion zone of a continuous combustion system, such as of the gas turbine engine type. The time-varying voltage induces a time-varying current in the flame which is measured and used to determine flame capacitance using AC electrical circuit analysis. Flame capacitance is used to accurately determine the position of the flame from the sensor and the fuel/air ratio. The fuel and/or air flow rate (s) is/are then adjusted to provide reduced flame instability problems such as flashback, combustion dynamics and lean blowout, as well as reduced emissions. The time-varying voltage may be an alternating voltage and the time-varying current may be an alternating current.

Chorpening, Benjamin T. (Morgantown, WV); Thornton, Jimmy D. (Morgantown, WV); Huckaby, E. David (Morgantown, WV); Fincham, William (Fairmont, WV)

2011-04-19T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Sinusoidal voltage controlled oscillators using operational transconductance amplifiers  

E-Print Network [OSTI]

SINUSOIDAI. VOLTAGE CONTROLLED OSCILLATORS I. SING OPERATIONAL TRANSCONDUCTANCE AMPLIFIERS A Thesis JAVIFB . IOAQUIN HOYI. K I'ASSANO Suhndtted to the Graduate College ol' 'I'exes A8cM University in partial fulfillment of the requirement... for the degree of MASTER OF SCIENCE May 1985 Major Subject: Electrical Engineering SINUSOIDAL VOLTAGE CONTROLLED OSCILLATORS USING OPERATIONAI, TRANSCONDUCTANCE AMPLIFIERS A Thesis by JAVIER JOAQUIN HOYLE PASSANO Approved as to style and content by: o...

Hoyle Passano, Javier Joaquin

1985-01-01T23:59:59.000Z

202

Image-line voltage controlled oscillators and grating antennas  

E-Print Network [OSTI]

IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Submitted to the Office of Graduate Studies of Texas ABM University in partial fulfillment of the requirements for the degree of MASTER... OF SCIENCE May 1991 Major Subject: Electrical Engineering IMAGE-LINE VOLTAGE CONTROLLED OSCILLATORS AND GRATING ANTENNAS A Thesis by ALEXANDER MacDONALD KIRK Approved as to style and content by: Kai Chang (Chair of Committee) Robert D. Nevels...

Kirk, Alexander MacDonald

1991-01-01T23:59:59.000Z

203

Design issues for high voltage converters for ion engines  

SciTech Connect (OSTI)

A design strategy is presented for a power converter for a high voltage ion engine for a spacecraft application. Various design issues such as appropriate topologies and control methods are considered. In this particular instance it was determined that a full bridge converter with phase shift gating and voltage mode control provided an efficient system with a minimum of electromagnetic interference. This system can be implemented in a straightforward manner, and it is relatively easy to protect from faults at the output.

King, R.J.; Stuart, T.A. [Univ. of Toledo, OH (United States)

1995-12-31T23:59:59.000Z

204

LM111/LM211/LM311 Voltage Comparator  

E-Print Network [OSTI]

LM111/LM211/LM311 Voltage Comparator 1.0 General Description The LM111, LM211 and LM311 are voltage comparators that have input currents nearly a thousand times lower than devices like the LM106 or LM710A. Both the inputs and the outputs of the LM111, LM211 or the LM311 can be isolated from system ground

Lanterman, Aaron

205

Measuring Helical FCG Voltage with an Electric Field Antenna  

SciTech Connect (OSTI)

A method of measuring the voltage produced by a helical explosive flux compression generator using a remote electric field antenna is described in detail. The diagnostic has been successfully implemented on several experiments. Measured data from the diagnostic compare favorably with voltages predicted using the code CAGEN, validating our predictive modeling tools. The measured data is important to understanding generator performance, and is measured with a low-risk, minimally intrusive approach.

White, A D; Anderson, R A; Javedani, J B; Reisman, D B; Goerz, D A; Ferriera, A J; Speer, R D

2011-08-01T23:59:59.000Z

206

Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells  

DOE Patents [OSTI]

Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl[sub 2] and SO[sub 2]Cl[sub 2] electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl[sub 2] and Li/SO[sub 2]Cl[sub 2] batteries.

Delnick, F.M.

1993-04-13T23:59:59.000Z

207

Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells  

DOE Patents [OSTI]

Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl.sub.2 and SO.sub.2 Cl.sub.2 electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl.sub.2 and Li/SO.sub.2 Cl.sub.2 batteries.

Delnick, Frank M. (Albuquerque, NM)

1993-01-01T23:59:59.000Z

208

Centralized wind power plant voltage control with optimal power flow algorithm.  

E-Print Network [OSTI]

??This thesis presents a method of controlling the reactive power injected into a medium-voltage collection system by multiple wind turbine generators such that the voltage… (more)

Kline, Jared Andrew

2011-01-01T23:59:59.000Z

209

High voltage electrical amplifier having a short rise time  

DOE Patents [OSTI]

A circuit, comprising an amplifier and a transformer is disclosed that produces a high power pulse having a fast response time, and that responds to a digital control signal applied through a digital-to-analog converter. The present invention is suitable for driving a component such as an electro-optic modulator with a voltage in the kilovolt range. The circuit is stable at high frequencies and during pulse transients, and its impedance matching circuit matches the load impedance with the output impedance. The preferred embodiment comprises an input stage compatible with high-speed semiconductor components for amplifying the voltage of the input control signal, a buffer for isolating the input stage from the output stage; and a plurality of current amplifiers connected to the buffer. Each current amplifier is connected to a field effect transistor (FET), which switches a high voltage power supply to a transformer which then provides an output terminal for driving a load. The transformer comprises a plurality of transmission lines connected to the FETs and the load. The transformer changes the impedance and voltage of the output. The preferred embodiment also comprises a low voltage power supply for biasing the FETs at or near an operational voltage.

Christie, David J. (Pleasanton, CA); Dallum, Gregory E. (Livermore, CA)

1991-01-01T23:59:59.000Z

210

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360{degree}/n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load. 7 figs.

Shimer, D.W.; Lange, A.C.

1997-03-11T23:59:59.000Z

211

E-beam high voltage switching power supply  

DOE Patents [OSTI]

A high power, solid state power supply is described for producing a controllable, constant high voltage output under varying and arcing loads suitable for powering an electron beam gun or other ion source. The present power supply is most useful for outputs in a range of about 100-400 kW or more. The power supply is comprised of a plurality of discrete switching type dc-dc converter modules, each comprising a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, and an output rectifier for producing a dc voltage at the output of each module. The inputs to the converter modules are fed from a common dc rectifier/filter and are linked together in parallel through decoupling networks to suppress high frequency input interactions. The outputs of the converter modules are linked together in series and connected to the input of the transmission line to the load through a decoupling and line matching network. The dc-dc converter modules are phase activated such that for n modules, each module is activated equally 360.degree./n out of phase with respect to a successive module. The phased activation of the converter modules, combined with the square current waveforms out of the step up transformers, allows the power supply to operate with greatly reduced output capacitance values which minimizes the stored energy available for discharge into an electron beam gun or the like during arcing. The present power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle using simulated voltage feedback signals and voltage feedback loops. Circuitry is also provided for sensing incipient arc currents reflected at the output of the power supply and for simultaneously decoupling the power supply circuitry from the arcing load.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1997-01-01T23:59:59.000Z

212

Voltage control in pulsed system by predict-ahead control  

DOE Patents [OSTI]

A method and apparatus for predict-ahead pulse-to-pulse voltage control in a pulsed power supply system is disclosed. A DC power supply network is coupled to a resonant charging network via a first switch. The resonant charging network is coupled at a node to a storage capacitor. An output load is coupled to the storage capacitor via a second switch. A de-Q-ing network is coupled to the resonant charging network via a third switch. The trigger for the third switch is a derived function of the initial voltage of the power supply network, the initial voltage of the storage capacitor, and the present voltage of the storage capacitor. A first trigger closes the first switch and charges the capacitor. The third trigger is asserted according to the derived function to close the third switch. When the third switch is closed, the first switch opens and voltage on the node is regulated. The second trigger may be thereafter asserted to discharge the capacitor into the output load. 4 figs.

Payne, A.N.; Watson, J.A.; Sampayan, S.E.

1994-09-13T23:59:59.000Z

213

DATE04 SPECIAL SECTION Overhead-conscious voltage selection for dynamic  

E-Print Network [OSTI]

combination with dynamic voltage scaling indispensable for energy-efficient designs in the foreseeable future

Marchal, Loris

214

Requirements for a Standard Test to Rate the Durability of PV Modules at System Voltage (Presentation)  

SciTech Connect (OSTI)

Degradation modes in photovoltaic modules under system bias voltage stress are described and classified.

Hacke, P.; Terwilliger, K.; Glick, S.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-02-01T23:59:59.000Z

215

Concept of Quasi-Capacitive Tapping of Bipolar Voltage-Controlled Oscillators  

E-Print Network [OSTI]

Concept of Quasi-Capacitive Tapping of Bipolar Voltage-Controlled Oscillators Aleksandar Tasic the active part of the oscillator and the LC-tank, as proposed in this paper, the voltage swing over the tank of high- performance bipolar voltage-controlled oscillators (VCO's). As the voltage-controlled oscillators

Serdijn, Wouter A.

216

Neurocomputing 69 (2006) 10621065 Dependence of the spike-triggered average voltage on  

E-Print Network [OSTI]

.V. All rights reserved. Keywords: Spike-triggered voltage; h-current; Damped voltage oscillations 1 oscillations. The model comprises a variable v for the membrane voltage, with time-scale tv and a secondNeurocomputing 69 (2006) 1062­1065 Dependence of the spike-triggered average voltage on membrane

Gerstner, Wulfram

2006-01-01T23:59:59.000Z

217

Radio-Frequency Interference (RFI) From Extra-High-Voltage (EHV) Transmission Lines  

E-Print Network [OSTI]

-current (HVAC) transmission lines; high-voltage direct-current (HVDC) transmission lines will be addressed

Ellingson, Steven W.

218

High voltage stability performance of a gamma ray detection device  

SciTech Connect (OSTI)

An industrial grade digital radiation survey meter device is currently being developed at Malaysian Nuclear Agency. This device used a cylindrical type Geiger Mueller (GM) which acts as a detector. GM detector operates at relatively high direct current voltages depend on the type of GM tube. This thin/thick walled cylindrical type of GM tube operates at 450-650 volts range. Proper value and stability performance of high voltage are important parameters to ensure that this device give a reliable radiation dose measurement. This paper will present an assessment of the stability and performance of the high voltage supply for radiation detector. The assessment is performed using System Identification tools box in MATLAB and mathematical statistics.

Abdullah, Nor Arymaswati; Lombigit, Lojius; Rahman, Nur Aira Abd [Technical Support Division, Malaysian Nuclear Agency, 43000 Kajang, Selangor (Malaysia)

2014-02-12T23:59:59.000Z

219

Voltage Impacts of Utility-Scale Distributed Wind  

SciTech Connect (OSTI)

Although most utility-scale wind turbines in the United States are added at the transmission level in large wind power plants, distributed wind power offers an alternative that could increase the overall wind power penetration without the need for additional transmission. This report examines the distribution feeder-level voltage issues that can arise when adding utility-scale wind turbines to the distribution system. Four of the Pacific Northwest National Laboratory taxonomy feeders were examined in detail to study the voltage issues associated with adding wind turbines at different distances from the sub-station. General rules relating feeder resistance up to the point of turbine interconnection to the expected maximum voltage change levels were developed. Additional analysis examined line and transformer overvoltage conditions.

Allen, A.

2014-09-01T23:59:59.000Z

220

A study of temperature compensating circuits for voltage references which use negative temperature coefficient zener diodes  

E-Print Network [OSTI]

Character- istics in Breakdown Region . 13 3f. 1N 751 Zener Diode Voltage vs Current Character- istics in Breakdown Region . 14 3g, lN752 Zener Diode Voltage vs Current Character- istics in Breakdown Region 15 4a. 1N746 Zener Diode Ambient Temperature... vs Voltage Characteristics in Breakdown Region. . . . . . . . . . 16 4b. IN747 Zener Diode Ambient Temperature vs Voltage Characteristics in Breakdown Region. . . . . . . . . . 17 4c. 1N748 Zener Diode Ambient Temperature vs Voltage...

Coleman, Spencer Delano

1961-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Reduction of interference on substation low voltage wiring  

SciTech Connect (OSTI)

This paper describes test results and mitigation methods of electromagnetic interference (EMI) on control and low voltage circuits in substations caused by air disconnect switch operation. The tests are focused on a comparison between unshielded and shielded circuits from capacitively coupled voltage transformers (CCVT) and other equipment circuits in the vicinity. New test data are presented comparing unshielded and shielded cables and transient currents on all connections to the CCVT including the pedestal and ground strap. The paper gives a practical and understandable explanation of the causes of EMI in substations and how shielded cable and parallel ground conductors reduce interference. Design guidelines are listed in the Conclusion.

Gavazza, R.J. [Pacific Gas and Electric Co., San Francisco, CA (United States)] [Pacific Gas and Electric Co., San Francisco, CA (United States); Wiggins, C.M. [Carl M. Wiggins and Associates, Friendswood, TX (United States)] [Carl M. Wiggins and Associates, Friendswood, TX (United States)

1996-07-01T23:59:59.000Z

222

Experimental characterization of faults on low-voltage systems  

E-Print Network [OSTI]

arcing ground faults '10'. The first scheme is very similar to the Ground Sensor Protection scheme described in i8j. The second scheme employs the fact that the voltage waveshape at the 1'suit point is flat topped. Harmonic analysis shows that... value when an arcing fault takes place. Continued presence of a, relatively high third- harmonic component in the bus voltage is a definite sign that there is an arcing fault in the system, Kusko and Peeran recommended the use of a, third harmonic...

Ahmed, Jubayer

1992-01-01T23:59:59.000Z

223

Conditions for Capacitor Voltage Regulation in a Five-Level Cascade Multilevel Inverter: Application to Voltage-Boost in a PM Drive  

E-Print Network [OSTI]

Conditions for Capacitor Voltage Regulation in a Five-Level Cascade Multilevel Inverter Abstract-- A cascade multilevel inverter is a power electronic device built to synthesize a desired AC voltage from several levels of DC voltages. Such inverters have been the subject of research in the last

Tolbert, Leon M.

224

Chapter 24: Alternating-Current Circuits 2. The voltage in the European wall socket oscillates between the positive and negative peak voltages, resulting in an rms  

E-Print Network [OSTI]

1 Chapter 24: Alternating-Current Circuits 2. The voltage in the European wall socket oscillates 240 V 340 VV V 6. A light bulb dissipates power as the voltage oscillates across its filament.0 V 1.32 A 15.2 V I X 13. An oscillating voltage drives an alternating current through a capacitor

Kioussis, Nicholas

225

Voltage Sequence Control Based High-Current Rectifier System  

E-Print Network [OSTI]

of transformer. A passive filter is added at the primary side to achieve power factor improvement over the range of output voltage. This scheme is optimized to determine optimum turns ratio of the transformer and optimum not enforce unity power factor operation and guidelines provided by harmonic standards such as IEEE-519

Paderborn, Universität

226

Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids  

E-Print Network [OSTI]

Hierarchical Control Scheme for Voltage Unbalance Compensation in Islanded Microgrids Mehdi@et.aau.dk Abstract-- The concept of microgrid hierarchical control is presented, recently. In this paper, a hierarchical scheme which includes primary and secondary control levels is proposed for islanded microgrids

Vasquez, Juan Carlos

227

ORIGINAL ARTICLES Induced Transmembrane Voltage and Its Correlation  

E-Print Network [OSTI]

to investigate the correlation between DWm and molecular transport through an elec- troporated membrane to a voltage (electric potential difference) caused by a system of ion pumps and channels in the membrane, or electropermea- bilization, and permits transmembrane transport of mole- cules for which an intact membrane

Ljubljana, University of

228

Topical Review Voltage Dependence of the Na/K Pump  

E-Print Network [OSTI]

or ``ion well'' hy- pothesis. There are only two ways that net transport can be voltage dependent. Either of the external Na+ and K+ bind- ing sites within the membrane field. This access channel or ``ion well produced by applying a blocking Key words: Na,K-ATPase -- Membrane potential -- Access channel -- Ion well

Gadsby, David

229

Current isolating epitaxial buffer layers for high voltage photodiode array  

DOE Patents [OSTI]

An array of photodiodes in series on a common semi-insulating substrate has a non-conductive buffer layer between the photodiodes and the semi-insulating substrate. The buffer layer reduces current injection leakage between the photodiodes of the array and allows optical energy to be converted to high voltage electrical energy.

Morse, Jeffrey D. (Martinez, CA); Cooper, Gregory A. (Pleasant Hill, CA)

2002-01-01T23:59:59.000Z

230

Ultra LowVoltage Delay Locked Loop Using Carbon Nanotubes  

E-Print Network [OSTI]

Ultra LowVoltage Delay Locked Loop Using Carbon Nanotubes J.S. Ajit Northeastern University Dept, MA 02115 E-mail: ybk@ece.neu.edu AbstractCarbon Nanotube FET technology is investigated for both the shrinking process to continue, and for the development of novel architectures, is the carbon

Ayers, Joseph

231

Memory Power Management via Dynamic Voltage/Frequency Scaling  

E-Print Network [OSTI]

years. In the data center environment, thermal management and power budgeting have become significant transitions [10, 23], or scal- ing active server power proportionally to load [2]. In this paper, we focusMemory Power Management via Dynamic Voltage/Frequency Scaling Howard David, Chris Fallin§, Eugene

McGaughey, Alan

232

Memory Power Management via Dynamic Voltage/Frequency Scaling  

E-Print Network [OSTI]

years. In the data center environment, thermal management and power budgeting have become significant sleep transitions [10, 23], or scal- ing active server power proportionally to load [2]. In this paperMemory Power Management via Dynamic Voltage/Frequency Scaling Howard David, Chris Fallin§, Eugene

Mutlu, Onur

233

The Matrix Converter Drive Performance Under Abnormal Input Voltage Conditions  

E-Print Network [OSTI]

that generates variable magnitude variable frequency output voltage from the ac utility line. It has high power conversion device, the disturbances at the ac utility grid (line) side are immediately reflected to the load and large capacitor associated with it, there is no stored energy in the MC. As a result, the utility line

Hava, Ahmet

234

Power flow analysis for DC voltage droop controlled DC microgrids  

E-Print Network [OSTI]

loss, such as photovoltaic panels, batteries, fuel cells, LEDs, and electronic loads, DC microgrids sharing and secondary voltage regulation can now be analytically studied, and specialized optimization of the DC microgrid, in term of systematic analysis, protection coordination design, network optimization

Chaudhary, Sanjay

235

Way to reduce arc voltage losses in hybrid thermionic converters  

SciTech Connect (OSTI)

Experimental results are reported concerning the output and emission characteristics of the arc and hybrid regimes in a plane-parallel thermionic converter with Pt--Zr--O electrode pair. It is shown that arc voltage losses can be reduced to values below those obtainable in ordinary arc thermionic converters.

Tskhakaya, V.K.; Yarygin, V.I.

1982-03-01T23:59:59.000Z

236

Field Optimization of Three Dimensional High Voltage C. Trinitis  

E-Print Network [OSTI]

Field Optimization of Three Dimensional High Voltage Equipment C. Trinitis Lehrstuhl f The goal of finding an optimal electric field strength distribution for arbitrary three di­ mensional­ cal optimization algorithm. The package ob­ tained from these three components is then able

Stamatakis, Alexandros

237

High Voltage DC Transmission 1.0 Introduction  

E-Print Network [OSTI]

1 High Voltage DC Transmission 1.0 Introduction HVDC has been applied in electric power systems for many years now. Figure 1 illustrates worldwide many of the HVDC applications [1]. Fig. 1 ABB provides a webpage which summarizes HVDC projects by type and capacity or by commissioning year [2]. Wikipedia [3

McCalley, James D.

238

High Voltage DC Transmission 2 1.0 Introduction  

E-Print Network [OSTI]

1 High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires on use of switching devices collectively referred to in the HVDC community as valves. Valves may be non. Fig. 1 There have been three types of devices for implementing HVDC converter circuits: mercury

McCalley, James D.

239

Smart Grid Voltage Sag Detection using Instantaneous Features Extraction  

E-Print Network [OSTI]

Smart Grid Voltage Sag Detection using Instantaneous Features Extraction Yassine Amirat, Mohamed Benbouzid, Tianzhen Wang and Sylvie Turri Abstract--Smart grids have initiated a radical reappraisal, and effective use of the network are indexed as the most important keys for smart grid expansion and deployment

Boyer, Edmond

240

Low Beam Voltage, 10 MW, L-Band Cluster Klystron  

SciTech Connect (OSTI)

Conceptual design of a multi-beam klystron (MBK) for possible ILC and Project X applications is presented. The chief distinction between this MBK design and existing 10-MW MBK's is the low operating voltage of 60 kV. There are at least four compelling reasons that justify development at this time of a low-voltage MBK, namely (1) no pulse transformer; (2) no oil tank for high-voltage components and for the tube socket; (3) no high-voltage cables; and (4) modulator would be a compact 60-kV IGBT switching circuit. The proposed klystron consists of four clusters containing six beams each. The tube has common input and output cavities for all 24 beams, and individual gain cavities for each cluster. A closely related optional configuration, also for a 10 MW tube, would involve four totally independent cavity clusters with four independent input cavities and four 2.5 MW output ports, all within a common magnetic circuit. This option has appeal because the output waveguides would not require a controlled atmosphere, and because it would be easier to achieve phase and amplitude stability as required in individual SC accelerator cavities.

Teryaev, V.; /Novosibirsk, IYF; Yakovlev, V.P.; /Fermilab; Kazakov, S.; /KEK, Tsukuba; Hirshfield, J.L.; /Yale U. /Omega-P, New Haven

2009-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Addition and subtraction of spin pumping voltages in magnetic hybrid structures  

SciTech Connect (OSTI)

We report an investigation of the spin pumping voltage generated in bilayers of ferromagnetic/normal metal in which the ferromagnetic layer is yttrium iron garnet or Permalloy and the normal-metal layer is Pt or Ta. We also investigated a special case in which the voltage is detected in single layer of Permalloy under ferromagnetic resonance condition. It is shown that the spin pumping voltage generated in metallic bilayers have contributions from both layers and the resulting voltage depends on the relative signs of charge currents generated by the inverse spin Hall effect. For instance, the spin pumping voltage generated in Ta has the same sign as the one generate in single layer of Permalloy, but contrary to the voltage generated in Pt. When the voltage is measured in shunted metallic bilayers, the resulting voltage can be a sum or a subtraction of the voltages generated in both layers.

Azevedo, A., E-mail: aac@df.ufpe.br; Alves Santos, O.; Cunha, R. O.; Rezende, S. M. [Departamento de Física, Universidade Federal de Pernambuco, 50670-901 Recife, PE (Brazil); Rodríguez-Suárez, R. [Facultad de Física, Pontificia Universidad Católica de Chile, Casilla 306, Santiago (Chile)

2014-04-14T23:59:59.000Z

242

Optimal Distributed Voltage Regulation in Power Distribution Networks  

E-Print Network [OSTI]

In this paper, we address the problem of voltage regulation in power distribution networks with deep-penetration of distributed energy resources (DERs), e.g., renewable-based generation, and storage-capable loads such as plug-in hybrid electric vehicles. We cast the problem as an optimization program, where the objective is to minimize the losses in the network subject to constraints on bus voltage magnitudes, limits on active and reactive power injections, transmission line thermal limits and losses. We provide sufficient conditions under which the optimization problem can be solved via its convex relaxation. Using data from existing networks, we show that the conditions are expected to be satisfied by most networks. We also provide an efficient distributed algorithm to solve the problem. The algorithm is asynchronous, with a communication topology that is the same as the electrical network topology. We illustrate the algorithm's performance in the IEEE 34-bus and the 123-bus feeder test systems.

Lam, Albert Y S; Dominguez-Garcia, Alejandro; Tse, David

2012-01-01T23:59:59.000Z

243

Analysis of Solar Cell Quality Using Voltage Metrics: Preprint  

SciTech Connect (OSTI)

The highest efficiency solar cells provide both excellent voltage and current. Of these, the open-circuit voltage (Voc) is more frequently viewed as an indicator of the material quality. However, since the Voc also depends on the band gap of the material, the difference between the band gap and the Voc is a better metric for comparing material quality of unlike materials. To take this one step further, since Voc also depends on the shape of the absorption edge, we propose to use the ultimate metric: the difference between the measured Voc and the Voc calculated from the external quantum efficiency using a detailed balance approach. This metric is less sensitive to changes in cell design and definition of band gap. The paper defines how to implement this metric and demonstrates how it can be useful in tracking improvements in Voc, especially as Voc approaches its theoretical maximum.

Toberer, E. S.; Tamboli, A. C.; Steiner, M.; Kurtz, S.

2012-06-01T23:59:59.000Z

244

Evaluation of Conservation Voltage Reduction (CVR) on a National Level  

SciTech Connect (OSTI)

Conservation Voltage Reduction (CVR) is a reduction of energy consumption resulting from a reduction of feeder voltage. While there have been numerous CVR systems deployed in North America there has been little substantive analytic analysis of the effect; the majority of the published results are based on empirical field measurements. Since these results are based on empirical measurements it is difficult to extrapolate how this technology will behave on the various types of distribution feeders found throughout the nation. This report has utilized the Taxonomy of Prototypical feeder developed under the Modern Grid Initiative (MGI), now the Modern Grid Strategy (MGS), in order to estimate the benefits of CVR on multiple distribution feeder types. This information will then be used to determine an estimate of the national benefits of a wide scale deployment of CVR.

Schneider, Kevin P.; Fuller, Jason C.; Tuffner, Francis K.; Singh, Ruchi

2010-09-29T23:59:59.000Z

245

Dynamic photorefractivity guided by single-pulse voltage  

SciTech Connect (OSTI)

The dynamic photorefractivity in a cell with photoconducting orienting layers, filled with a nematic liquid crystal (LC) 6CHBT and a mixture of anthraquinone dyes AD1 and AD2, has been investigated. The single-pulse mode, in which the polarity and amplitude of a dc electric field applied to an LC cell are switched for a fixed time interval, has been used. The scheme of dynamic self-diffraction of low-power laser beams was used in the experiment. The dependences of the width and intensity of diffraction pulses on the bias and switching voltages have been investigated. It is established that the width and intensity of the diffraction pulse arising after initial voltage recovery depends also on the switching pulse width. At the optimal width of the control pulse, the diffraction efficiency increases by two orders of magnitude.

Agashkov, A. V., E-mail: agashkov@inel.bas.net.by; Kovalev, A. A. [National Academy of Sciences of Belarus, Institute of Electronics (Belarus); Parka, J. [Military University of Technology, Institute of Applied Physics (Poland)

2008-03-15T23:59:59.000Z

246

Interline photovoltaic (I-PV) power plants for voltage unbalance compensation  

E-Print Network [OSTI]

This paper proposes a stationary-frame control method for voltage unbalance compensation using Interline Photovoltaic (I-PV) power system. I-PV power systems are controlled to compensate voltage unbalance autonomously. The ...

Moawwad, Ahmed

247

A low-voltage zero-crossing-based delta-sigma analog-to-digital converter  

E-Print Network [OSTI]

A zero-crossing-based (ZCB) switched-capacitor technique is presented for operation under low power supply voltages without gate boosting. Voltage ramp generators maintain common-mode level at each integrator output. ...

Guyton, Matthew C. (Matthew Christopher)

2010-01-01T23:59:59.000Z

248

E-Print Network 3.0 - applied voltages ii Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

dc-link voltage error is applied to the fun... --In this paper, a new hybrid active power filter topology is presented. A higher-voltage, low-switching fre... - quency...

249

E-Print Network 3.0 - ac voltage standard Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

"volts, AC"), the "secondary" voltage is roughly 6 VAC. We shall use the "Universal Transformer... :" conversion of AC to DC You can use a diode to convert the AC voltage of the...

250

Low Voltage Reversible Electrowetting Exploiting Lubricated Polymer Honeycomb Substrates  

E-Print Network [OSTI]

Low-voltage electrowetting-on-dielectric scheme realized with lubricated honeycomb polymer surfaces is reported. Polycarbonate honeycomb reliefs manufactured with the breath-figures self-assembly were impregnated with silicone and castor oils. The onset of the reversible electrowetting for silicone oil impregnated substrates occurred at 35 V, whereas for castor oil impregnated ones it took place at 80 V. The semi-quantitative analysis of electrowetting of impregnated surfaces is proposed.

Edward Bormashenko; Roman Pogreb; Yelena Bormashenko; Roman Grynyov; Oleg Gendelman

2014-06-16T23:59:59.000Z

251

Advanced Gate Drive for the SNS High Voltage Converter Modulator  

SciTech Connect (OSTI)

SLAC National Accelerator Laboratory is developing a next generation H-bridge switch plate [1], a critical component of the SNS High Voltage Converter Modulator [2]. As part of that effort, a new IGBT gate driver has been developed. The drivers are an integral part of the switch plate, which are essential to ensuring fault-tolerant, high-performance operation of the modulator. The redesigned driver improves upon the existing gate drive in several ways. The new gate driver has improved fault detection and suppression capabilities; suppression of shoot-through and over-voltage conditions, monitoring of dI/dt and Vce(sat) for fast over-current detection and suppression, and redundant power isolation are some of the added features. In addition, triggering insertion delay is reduced by a factor of four compared to the existing driver. This paper details the design and performance of the new IGBT gate driver. A simplified schematic and description of the construction are included. The operation of the fast over-current detection circuits, active IGBT over-voltage protection circuit, shoot-through prevention circuitry, and control power isolation breakdown detection circuit are discussed.

Nguyen, M.N.; Burkhart, C.; Kemp, M.A.; /SLAC; Anderson, D.E.; /Oak Ridge

2009-05-07T23:59:59.000Z

252

Linear inductive voltage adders (IVA) for advanced hydrodynamic radiography  

SciTech Connect (OSTI)

The electron beam which drifts through the multiple cavities of conventional induction linacs (LIA) is replaced in an IVA by a cylindrical metal conductor which extends along the entire length of the device and effectuates the addition of the accelerator cavity voltages. In the approach to radiography, the linear inductive voltage adder drives a magnetically immersed electron diode with a millimeter diameter cathode electrode and a planar anode/bremsstrahlung converter. Both anode and cathode electrodes are immersed in a strong (15--50 T) solenoidal magnetic field. The electron beam cross section is approximately of the same size as the cathode needle and generates a similar size, very intense x-ray beam when it strikes the anode converter. An IVA driven diode can produce electron beams of equal size and energy as a LIA but with much higher currents (40--50 kA versus 4--5 kA), simpler hardware and thus lower cost. The authors present here first experimental validations of the technology utilizing HERMES 3 and SABRE IVA accelerators. The electron beam voltage and current were respectively of the order of 10 MV and 40 kA. X-ray doses of up to 1 kR {at} 1 m and spot sizes as small as 1.7 mm (at 200 R doses) were measured.

Mazarakis, M.G.; Boyes, J.D.; Johnson, D.L. [and others

1998-09-01T23:59:59.000Z

253

The vertical voltage termination technique characterizations of single die multiple 600V power  

E-Print Network [OSTI]

The vertical voltage termination technique ­ characterizations of single die multiple 600V power.grenoble-inp.fr Abstract-- Deep trench terminations are commonly known as a technique to achieve ideal breakdown voltages for high voltage devices. This paper presents the use of deep trench terminations as an original concept

Paris-Sud XI, Université de

254

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power Filter Applications  

E-Print Network [OSTI]

Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power voltage-source inverters connected in series (known as cascaded hybrid asymmetric multilevel inverter scheme is developed to allow the operation of the inverter modules at different voltages and switching

Catholic University of Chile (Universidad CatĂłlica de Chile)

255

Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines  

E-Print Network [OSTI]

Low-Voltage Ride-Through Techniques for DFIG-Based Wind Turbines: State-of-the-Art Review deals with low-voltage ride-through (LVRT) capability of wind turbines (WTs) and in particular those as to index some emerging solutions. Index Terms--Wind turbine, doubly-fed induction generator, low voltage

Paris-Sud XI, Université de

256

Re-Dispatching Generation to Increase Power System Security Margin and Support Low Voltage Bus  

E-Print Network [OSTI]

Re-Dispatching Generation to Increase Power System Security Margin and Support Low Voltage Bus by re-dispatching generator outputs, using a normal vector found at a voltage collapse boundary or a low voltage boundary (LVB). This method uses the normal vector as an indicator to change the generation

257

Parameter Variation Analysis for Voltage Controlled Oscillators in Phase-Locked Loops  

E-Print Network [OSTI]

Parameter Variation Analysis for Voltage Controlled Oscillators in Phase-Locked Loops Igor Vytyaz), the oscillation frequency of a voltage-controlled oscillator (VCO) is specified by the reference frequency on the oscillation frequency as the PLL adjusts the control voltage to keep the frequency unchanged. More importantly

Moon, Un-Ku

258

1. ABSTRACT A 1.4-GHz LC voltage-controlled oscillator has  

E-Print Network [OSTI]

1. ABSTRACT A 1.4-GHz LC voltage-controlled oscillator has been implemented in a MOSIS 0.5-µm CMOS integrated, low noise, low power voltage-controlled oscillator (VCO). For higher quality receivers, an LC the overall phase noise. In this paper, we present such an LC voltage-controlled oscillator fabricated through

Lee, Thomas H.

259

EFFECTS OF SUBSTRATE ON PHASE-NOISE OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS  

E-Print Network [OSTI]

EFFECTS OF SUBSTRATE ON PHASE-NOISE OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS Aleksandar Tasic predict a dramatically different performance of the oscillators, being different phase-noise, voltage of quasi-tapped bipolar voltage-controlled oscillators [2], phase- noise being of most interest. Contrary

Serdijn, Wouter A.

260

Fast Optimization of Nano-CMOS Voltage-Controlled Oscillator using Polynomial Regression and Genetic Algorithm  

E-Print Network [OSTI]

Fast Optimization of Nano-CMOS Voltage-Controlled Oscillator using Polynomial Regression in a current-starved 50nm voltage-controlled oscillator (VCO). Accurate polynomial-regression based models have-CMOS), Voltage-Controlled Oscillator (VCO). 1. Introduction Digital design exploration and optimization is highly

Mohanty, Saraju P.

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

CONCEPT OF FREQUENCY-TRANSCONDUCTANCE TUNING OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS  

E-Print Network [OSTI]

CONCEPT OF FREQUENCY-TRANSCONDUCTANCE TUNING OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS Aleksandar-transconductance tuning, introduced in this paper, offers the possibility for voltage-controlled oscillators to trade-tank, the loop-gain, the voltage swing and the phase-noise of the oscillator are changed as well

Serdijn, Wouter A.

262

Understanding Pound-Drever-Hall locking using voltage controlled radio-frequency oscillators: An undergraduate experiment  

E-Print Network [OSTI]

Understanding Pound-Drever-Hall locking using voltage controlled radio-frequency oscillators. The three main pieces of equipment are a commercial voltage controlled oscillator, a resonating cavity of the voltage controlled oscillator. The cavity resonance is then observed by scanning the frequency

Le Roy, Robert J.

263

Milligram-Scale High-Voltage Power Electronics for Piezoelectric Microrobots  

E-Print Network [OSTI]

, the generation of high voltages for HMF actu- ators requires voltage conversion circuits with step-up ratios to the voltage step-up functionality, the power electronics circuitry must generate a time-varying signal ranging from 50 to 100. While there are a number of circuit topologies with high step-up ratios, many

Wood, Robert

264

Application-Directed Voltage Scaling Johan Pouwelse, Koen Langendoen, and Henk Sips  

E-Print Network [OSTI]

--Clock (and voltage) scheduling is an important tech- nique to reduce the energy consumption of processors that sup- port voltage scaling. It is difficult, however, to achieve good re- sults using only statistics to the scheduler control- ling the clock speed and processor voltage. This paper describes our Energy Priority

Pouwelse, Johan

265

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares in the  

E-Print Network [OSTI]

An Approximate Dynamic Programming Algorithm for the Allocation of High-Voltage Transformer Spares high-voltage transformer spares throughout the electric grid to mitigate the risk of random transformer-voltage transformers are an integral part of the electric transmission system. A catas- trophic transformer failure

Powell, Warren B.

266

Voltage-Sensitivity of Motoneuron NMDA Receptor Channels Is Modulated by Serotonin in the Neonatal Rat Spinal Cord  

E-Print Network [OSTI]

isolated in tetrodotoxin, induces nonlinear membrane behavior that results in voltage oscillations which generate rhythmic voltage oscillations in the presence of NMDA and synaptic blockade (with tetrodotoxin application induces neither voltage oscillations (in synaptically isolated motoneurons) nor locomotor network

Manitoba, University of

267

Strategies for Voltage Control and Transient Stability Assessment  

SciTech Connect (OSTI)

As wind generation grows, its influence on power system performance will becoming increasingly noticeable. Wind generation di#11;ffers from traditional forms of generation in numerous ways though, motivating the need to reconsider the usual approaches to power system assessment and performance enhancement. The project has investigated the impact of wind generation on transient stability and voltage control, identifying and addressing issues at three distinct levels of the power system: 1) at the device level, the physical characteristics of wind turbine generators (WTGs) are quite unlike those of synchronous machines, 2) at the wind-farm level, the provision of reactive support is achieved through coordination of numerous dissimilar devices, rather than straightforward generator control, and 3) from a systems perspective, the location of wind-farms on the sub-transmission network, coupled with the variability inherent in their power output, can cause complex voltage control issues. The project has sought to develop a thorough understanding of the dynamic behaviour of type-3 WTGs, and in particular the WECC generic model. The behaviour of such models is governed by interactions between the continuous dynamics of state variables and discrete events associated with limits. It was shown that these interactions can be quite complex, and may lead to switching deadlock that prevents continuation of the trajectory. Switching hysteresis was proposed for eliminating deadlock situations. Various type-3 WTG models include control blocks that duplicate integrators. It was shown that this leads to non-uniqueness in the conditions governing steady-state, and may result in pre- and post-disturbance equilibria not coinciding. It also gives rise to a zero eigenvalue in the linearized WTG model. In order to eliminate the anomalous behaviour revealed through this investigation, WECC has now released a new generic model for type-3 WTGs. Wind-farms typically incorporate a variety of voltage control equipment including tapchanging transformers, switched capacitors, SVCs, STATCOMs and the WTGs themselves. The project has considered the coordinated control of this equipment, and has addressed a range of issues that arise in wind-farm operation. The #12;first concerns the ability of WTGs to meet reactive power requirements when voltage saturation in the collector network restricts the reactive power availability of individual generators. Secondly, dynamic interactions between voltage regulating devices have been investigated. It was found that under certain realistic conditions, tap-changing transformers may exhibit instability. In order to meet cost, maintenance, fault tolerance and other requirements, it is desirable for voltage control equipment to be treated as an integrated system rather than as independent devices. The resulting high-level scheduling of wind-farm reactive support has been investigated. In addressing this control problem, several forms of future information were considered, including exact future knowledge and stochastic predictions. Deterministic and Stochastic Dynamic Programming techniques were used in the development of control algorithms. The results demonstrated that while exact future knowledge is very useful, simple prediction methods yield little bene#12;fit. The integration of inherently variable wind generation into weak grids, particularly subtransmission networks that are characterized by low X=R ratios, aff#11;ects bus voltages, regulating devices and line flows. The meshed structure of these networks adds to the complexity, especially when wind generation is distributed across multiple nodes. A range of techniques have been considered for analyzing the impact of wind variability on weak grids. Sensitivity analysis, based on the power-flow Jacobian, was used to highlight sections of a system that are most severely a#11;ffected by wind-power variations. A continuation power flow was used to determine parameter changes that reduce the impact of wind-power variability. It was also used to explore interactions betw

Hiskens, Ian A.

2013-09-25T23:59:59.000Z

268

Voltage sensor with fiber Fabry-Perot interferometer  

E-Print Network [OSTI]

with smaller strain constants, a larger voltage must be applied to get a 2x round trip phase shift. Hence, a longer FFPI is needed to get higher resolution. 16 A plate type PZT was selected because it's more convenient to attach to a thermo-electric cooler... in electron-beam evaporation system, they can be spliced to uncoated fibers, which also have cleaved end surfaces. The basic configuration for this Siecor Model M 67 fusion splicer is shown in fig. 12. A electric arc is initiated between the electrodes...

Wann, Been-Huey

1992-01-01T23:59:59.000Z

269

Outdoor PV Module Degradation of Current-Voltage Parameters: Preprint  

SciTech Connect (OSTI)

Photovoltaic (PV) module degradation rate analysis quantifies the loss of PV power output over time and is useful for estimating the impact of degradation on the cost of energy. An understanding of the degradation of all current-voltage (I-V) parameters helps to determine the cause of the degradation and also gives useful information for the design of the system. This study reports on data collected from 12 distinct mono- and poly-crystalline modules deployed at the National Renewable Energy Laboratory (NREL) in Golden, Colorado. Most modules investigated showed < 0.5%/year decrease in maximum power due to short-circuit current decline.

Smith, R. M.; Jordan, D. C.; Kurtz, S. R.

2012-04-01T23:59:59.000Z

270

Light-weight DC to very high voltage DC converter  

DOE Patents [OSTI]

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

1998-01-01T23:59:59.000Z

271

Light-weight DC to very high voltage DC converter  

DOE Patents [OSTI]

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

Druce, R.L.; Kirbie, H.C.; Newton, M.A.

1998-06-30T23:59:59.000Z

272

Light-induced voltage alteration for integrated circuit analysis  

DOE Patents [OSTI]

An apparatus and method are described for analyzing an integrated circuit (IC). The invention uses a focused light beam that is scanned over a surface of the IC to generate a light-induced voltage alteration (LIVA) signal for analysis of the IC. The LIVA signal may be used to generate an image of the IC showing the location of any defects in the IC; and it may be further used to image and control the logic states of the IC. The invention has uses for IC failure analysis, for the development of ICs, for production-line inspection of ICs, and for qualification of ICs. 18 figs.

Cole, E.I. Jr.; Soden, J.M.

1995-07-04T23:59:59.000Z

273

Methods, systems and apparatus for controlling third harmonic voltage when operating a multi-space machine in an overmodulation region  

SciTech Connect (OSTI)

Methods, system and apparatus are provided for controlling third harmonic voltages when operating a multi-phase machine in an overmodulation region. The multi-phase machine can be, for example, a five-phase machine in a vector controlled motor drive system that includes a five-phase PWM controlled inverter module that drives the five-phase machine. Techniques for overmodulating a reference voltage vector are provided. For example, when the reference voltage vector is determined to be within the overmodulation region, an angle of the reference voltage vector can be modified to generate a reference voltage overmodulation control angle, and a magnitude of the reference voltage vector can be modified, based on the reference voltage overmodulation control angle, to generate a modified magnitude of the reference voltage vector. By modifying the reference voltage vector, voltage command signals that control a five-phase inverter module can be optimized to increase output voltages generated by the five-phase inverter module.

Perisic, Milun; Kinoshita, Michael H; Ranson, Ray M; Gallegos-Lopez, Gabriel

2014-06-03T23:59:59.000Z

274

Commercialization of Medium Voltage HTS Triax TM Cable Systems  

SciTech Connect (OSTI)

The original project scope that was established in 2007 aimed to install a 1,700 meter (1.1 mile) medium voltage HTS Triax{TM} cable system into the utility grid in New Orleans, LA. In 2010, however, the utility partner withdrew from the project, so the 1,700 meter cable installation was cancelled and the scope of work was reduced. The work then concentrated on the specific barriers to commercialization of HTS cable technology. The modified scope included long-length HTS cable design and testing, high voltage factory test development, optimized cooling system development, and HTS cable life-cycle analysis. In 2012, Southwire again analyzed the market for HTS cables and deemed the near term market acceptance to be low. The scope of work was further reduced to the completion of tasks already started and to testing of the existing HTS cable system in Columbus, OH. The work completed under the project included: • Long-length cable modeling and analysis • HTS wire evaluation and testing • Cable testing for AC losses • Optimized cooling system design • Life cycle testing of the HTS cable in Columbus, OH • Project management. The 200 meter long HTS Triax{TM} cable in Columbus, OH was incorporated into the project under the initial scope changes as a test bed for life cycle testing as well as the site for an optimized HTS cable cooling system. The Columbus cable utilizes the HTS TriaxTM design, so it provided an economical tool for these of the project tasks.

Knoll, David

2012-12-31T23:59:59.000Z

275

Bi-directional power control system for voltage converter  

DOE Patents [OSTI]

A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals. 10 figs.

Garrigan, N.R.; King, R.D.; Schwartz, J.E.

1999-05-11T23:59:59.000Z

276

Bi-directional power control system for voltage converter  

DOE Patents [OSTI]

A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

Garrigan, Neil Richard (Niskayuna, NY); King, Robert Dean (Schenectady, NY); Schwartz, James Edward (Slingerlands, NY)

1999-01-01T23:59:59.000Z

277

Performance and durability of PSA Peugeot Citroen's DPF System...  

Broader source: Energy.gov (indexed) [DOE]

Fleet in the Paris Area 2 Objectives Methodology of the program Regulated exhaust emissions Accumulation phase Regeneration phase Non-regulated exhaust emissions Gaseous...

278

Combination and Integration of DPF-SCR Aftertreatment Technologies  

Broader source: Energy.gov (indexed) [DOE]

INTEGRATION OVERVIEW Start - Oct 2008 Finish - Oct 2012 37% complete Barriers addressed Heavy truck thermal efficiency Aftertreatment cost Combined NOx and PM emissions * Total...

279

Recent Charmonium Results from BES (Talk Presented at DPF99)  

E-Print Network [OSTI]

Recent results obtained from the BES psi(2S) data are summarized, including the measurement of the branching ratio of the J/psi to leptons, B(J/psi -> l^+ l^-) = 5.87 +/- 0.04 +/- 0.09, many psi(2S) and chi_c branching ratios, information on the rho-pi puzzle, and measurements of the mass of the chi_c0, m(chi_c0) = 3414.1 +/- 0.6 +/- 0.8 MeV, and the eta_c, m(eta_c) = 2975.8 +/- 3.9 +/- 1.2 MeV.

F. A. Harris

1999-03-17T23:59:59.000Z

280

The Sensitivity of DPF Performance to the Spatial Distribution...  

Broader source: Energy.gov (indexed) [DOE]

Distribution of Ash Generated from Six Lubricant Formulations Presenter: Yujun Wang Advisor: Dr. Victor W. Wong October 18, 2012 Massachusetts Institute of Technology Sloan...

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Status of APBF-DEC NOx Adsorber/DPF Projects  

Broader source: Energy.gov (indexed) [DOE]

is Managed and Directed by Technical Committees DOE, EPA, additive companies, automobile manufacturers, engine manufacturers, energy companies, emission control mfrs.,...

282

Unraveling DPF Degradation using Chemical Tracers and Opportunities...  

Broader source: Energy.gov (indexed) [DOE]

Ash Sources Lubricant additives (Zn, Ca, Mg, S, P) Engine wear, corrosion, trace metals in fuels Source: K. Aravelli Courtesy: E. Senzer After only 33,000...

283

Development of Advanced Diesel Particulate Filtration (DPF) Systems...  

Broader source: Energy.gov (indexed) [DOE]

May 20, 2009 DOE Annual Merit Review & Peer Evaluation Meeting PI: Kyeong Lee (Postdoc: Seung Yang) Argonne National Laboratory DOE Project Managers: Kenneth Howden & Gurpreet...

284

Combination & Integration of DPF-SCR Aftertreatment Technologies  

Broader source: Energy.gov (indexed) [DOE]

for HDD to provide a pathway to the next generation of emissions control systems CRADA with PACCAR, working intimately with PTC and DAF Trucks N.V. Evolving field of work...

285

Experimental Studies for DPF and SCR Model, Control System, and...  

Broader source: Energy.gov (indexed) [DOE]

System, and OBD Development for Engines Using Diesel and Biodiesel Fuels John H. Johnson, P.I. Gordon G. Parker, Co-P.I. & Presenter Michigan Technological University 11 May...

286

Experimental Studies for DPF and SCR Model, Control System, and...  

Broader source: Energy.gov (indexed) [DOE]

System, and OBD Development for Engines Using Diesel and Biodiesel Fuels John H. Johnson, P.I. Gordon G. Parker, Co-P.I. & Presenter Jeffrey D. Naber, Co-PI Michigan...

287

Experimental Studies for DPF and SCR Model, Control System, and...  

Broader source: Energy.gov (indexed) [DOE]

System, and OBD Development for Engines Using Diesel and Biodiesel Fuels John H. Johnson, P.I. Gordon G. Parker, Co-P.I. & Presenter Michigan Technological University 9 June...

288

Towards Fuel-Efficient DPF Systems: Understanding the Soot Oxidation...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

2005deeryezerets.pdf More Documents & Publications Burning Modes and Oxidation Rates of Soot: Relevance to Diesel Particulate Traps Soot Nanostructure: Definition,...

289

Key Parameters Affecting DPF Performance Degradation and Impact...  

Broader source: Energy.gov (indexed) [DOE]

K K Potential to improve ash packing Additive Chemistry Impact on Ash Properties Lubricant matrix all formulated to 1% sulfated ash, except...

290

Key Parameters Affecting DPF Performance Degradation and Impact...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

More Documents & Publications Characteristics and Effects of Lubricant Additive Chemistry and Exhaust Conditions on Diesel Particulate Filter Service Life and Vehicle Fuel...

291

Unraveling DPF Degradation using Chemical Tracers and Opportunities...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

stability, and accuracy while incorporating single-cell structures and simple electronics into low-cost designs deer10sappok.pdf More Documents & Publications Key...

292

Combination & Integration of DPF-SCR Aftertreatment Technologies |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTieCelebrate Earth Codes and StandardsColleenActionDepartment of

293

Combination and Integration of DPF-SCR Aftertreatment Technologies |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTieCelebrate Earth Codes and StandardsColleenActionDepartmentDepartment

294

Combination and Integration of DPF-SCR Aftertreatment Technologies |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTieCelebrate Earth Codes and

295

Combination and Integration of DPF-SCR Aftertreatment Technologies |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTieCelebrate Earth Codes andDepartment of Energy 0 DOE Vehicle

296

Towards Fuel-Efficient DPF Systems: Understanding the Soot Oxidation  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of EnergyThe EnergyDepartment7 th ,Top Value AddedTotal EnergyProcess |

297

Key Parameters Affecting DPF Performance Degradation and Impact on Lifetime  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensionalthe10 DOEWashington, DC 20585on253.16582104)Key Issues Key

298

Diesel Particulate Filtration (DPF) Technology: Success stories at the High  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat Pump Models |Conduct, Parent CompanyaUSAMPRelatedEnergyEnergy

299

Development of Advanced Diesel Particulate Filtration (DPF) Systems |  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector General Office of Audit Services AuditTransatlantic RelationsDepartment ofEfficiency |

300

DPF Performance with Biodiesel Blends | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat Pump Models | Department1 Prepared by: U.S.-"Hydrated EGR" Fuel

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

DPF for a Tractor Auxiliary Power Unit | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat Pump Models | Department1 Prepared by: U.S.-"Hydrated EGR" Fuelfor a

302

Development of Advanced Diesel Particulate Filtration (DPF) Systems  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat Pump Models |Conduct, Parent Companya new high capacityofTechnology |4Efficiency

303

Development of Advanced Diesel Particulate Filtration (DPF) Systems |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat Pump Models |Conduct, Parent Companya new high capacityofTechnology

304

Development of Advanced Diesel Particulate Filtration (DPF) Systems |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat Pump Models |Conduct, Parent Companya new high capacityofTechnologyDepartment

305

Single Channel DPF Experiments to Investigate Soot Cake Structures |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage » SearchEnergyDepartment ofCombustuion | Department of Energy Lars

306

Emissions from the European Light Duty Diesel Vehicle During DPF  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE: ECMConstructionApplications |Applicationsa Suezmax

307

RYPOS - An Actively Regenerated DPF that Demonstrates Significant NO2  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l L dDepartment ofList? | DepartmentEnergySECTION A-B,Tools=Reduction

308

CFD Analysis of Particle Deposition During DPF Filtration Processes |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 <Ones | DepartmentCEEComponents |

309

Biofuels Impact on DPF Durability | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: ScopeDepartment1, 2011 (BETO) Projectdried2 DOE Hydrogen and

310

Biofuels Impact on DPF Durability | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: ScopeDepartment1, 2011 (BETO) Projectdried2 DOE Hydrogen and1

311

Microwave Regenerated DPF for Auxiliary Power Units and Diesel Hybrid  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l L d F S i DOE TribaltheMy name isProcurementEnergyWorkshop:Vehicles

312

Single Wall Diesel Particulate Filter (DPF) Filtration Efficiency Studies  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administrationcontroller systemsBi (2)Sharing Smart GridShiftMethodSimwYpes(tm) and47-000Single

313

Unraveling DPF Degradation using Chemical Tracers and Opportunities for  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of EnergyTheTwo New12.'6/0.2 ...... 13:27 FAX 301O R

314

Value Analysis of Alternative Diesel Particulate Filter (DPF) Substrates  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of EnergyTheTwoVulnerabilities | Department of|VTA,an Integrated April

315

Vehicle Evaluation of Downsized Dow ACM DPF | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of EnergyTheTwoVulnerabilities | DepartmentReactive Barrierof

316

Verifying TRU Passive DPF Cold Ambient Performance | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of| Department of Energy Ventilation System to

317

Value Analysis of Alternative Diesel Particulate Filter (DPF...  

Broader source: Energy.gov (indexed) [DOE]

PGM usage * Downsize the aftertreatment system * Integration of aftertreatment * Emission regulation * Improved efficiency * Reduce light-off time * Improved catalyst...

318

Over Voltage in a Multi-sectioned Solenoid during a Quenching  

SciTech Connect (OSTI)

Accurate analysis of over voltage in the superconducting solenoid during a quench is one of the bases for quench protection system design. Classical quench simulation methods can only give rough estimation of the over voltage within a magnet coil. In this paper, for multi-sectioned superconducting solenoid, based on the classical assumption of ellipsoidal normal zone, three-dimension al temperature results are mapped to the one-dimension of the wire, the temperature distribution along the wire and the resistances of each turn are obtained. The coil is treated as circuit comprised of turn resistances, turn self and mutual inductances. The turn resistive voltage, turn inductive voltage, and turn resultant voltage along the wire are calculated. As a result, maximum internal voltages, the layer-to-layer voltages and the turn-to-turn voltages are better estimated. Utilizing this method, the over voltage of a small solenoid and a large solenoid during quenching have been studied. The result shows that this method can well improve the over voltage estimate, especially when the coil is larger.

Guo, Xinglong; Wang, Li; Pan, Heng; Wu, Hong; Liu, Xiaokun; Chen, Anbin; Green, M.A.; Xu, F.Y.

2009-06-21T23:59:59.000Z

319

Control of Analyte Electrolysis in Electrospray Ionization Mass Spectrometry Using Repetitively Pulsed High Voltage  

SciTech Connect (OSTI)

Analyte electrolysis using a repetitively pulsed high voltage ion source was investigated and compared to that using a regular, continuously operating direct current high voltage ion source in electrospray ionization mass spectrometry. The extent of analyte electrolysis was explored as a function of the length and frequency of the high voltage pulse using the model compound reserpine in positive ion mode. Using +5 kV as the maximum high voltage amplitude, reserpine was oxidized to its 2, 4, 6 and 8-electron oxidation products when direct current high voltage was employed. In contrast, when using a pulsed high voltage, oxidation of reserpine was eliminated by employing the appropriate high voltage pulse length and frequency. This effect was caused by inefficient mass transport of the analyte to the electrode surface during the duration of the high voltage pulse and the subsequent relaxation of the emitter electrode/ electrolyte interface during the time period when the high voltage was turned off. This mode of ESI source operation allows for analyte electrolysis to be quickly and simply switched on or off electronically via a change in voltage pulse variables.

Kertesz, Vilmos [ORNL; Van Berkel, Gary J [ORNL

2011-01-01T23:59:59.000Z

320

Experiment and Simulation of Dynamic Voltage Regulation in Multiple Distributed Energy Resources Systems  

SciTech Connect (OSTI)

Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a microturbine with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction between the DEs is studied. The simulation results show the relationship between the voltages in the system and the reactive power required for the voltage regulation. Also, integrated voltage regulation (multiple DEs performing voltage regulation) can increase the voltage regulation capability of DEs and reduce the capital and operating costs.

Xu, Yan [ORNL; Li, Fangxing [ORNL; Kueck, John D [ORNL; Rizy, D Tom [ORNL

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

DECENTRALIZED CONTROL ARCHITECTURE FOR COUPLING MICROGRIDS INTO DISTRIBUTION NETWORKS 1 Task 1: Coupling Low-Voltage Microgrids into  

E-Print Network [OSTI]

DECENTRALIZED CONTROL ARCHITECTURE FOR COUPLING MICROGRIDS INTO DISTRIBUTION NETWORKS 1 Task 1: Coupling Low-Voltage Microgrids into Mid-Voltage Distribution Systems Zhao Wang, Student Member, IEEE-voltage (LV) microgrids. At the same time, reactive power is dispatched coordinatively so that voltage

Lemmon, Michael

322

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators  

E-Print Network [OSTI]

LM139/LM239/LM339/LM2901/LM3302 Low Power Low Offset Voltage Quad Comparators General Description The LM139 series consists of four independent precision voltage comparators with an offset voltage clock timers; multivibrators and high voltage digital logic gates. The LM139 series was designed

Lanterman, Aaron

323

Pulsed voltage electrospray ion source and method for preventing analyte electrolysis  

DOE Patents [OSTI]

An electrospray ion source and method of operation includes the application of pulsed voltage to prevent electrolysis of analytes with a low electrochemical potential. The electrospray ion source can include an emitter, a counter electrode, and a power supply. The emitter can include a liquid conduit, a primary working electrode having a liquid contacting surface, and a spray tip, where the liquid conduit and the working electrode are in liquid communication. The counter electrode can be proximate to, but separated from, the spray tip. The power system can supply voltage to the working electrode in the form of a pulse wave, where the pulse wave oscillates between at least an energized voltage and a relaxation voltage. The relaxation duration of the relaxation voltage can range from 1 millisecond to 35 milliseconds. The pulse duration of the energized voltage can be less than 1 millisecond and the frequency of the pulse wave can range from 30 to 800 Hz.

Kertesz, Vilmos (Knoxville, TN); Van Berkel, Gary (Clinton, TN)

2011-12-27T23:59:59.000Z

324

Bright and fast voltage reporters across the visible spectrum via electrochromic FRET (eFRET)  

E-Print Network [OSTI]

We present a palette of brightly fluorescent genetically encoded voltage indicators (GEVIs) with excitation and emission peaks spanning the visible spectrum, sensitivities from 6 - 10% Delta F/F per 100 mV, and half-maximal response times from 1 - 7 ms. A fluorescent protein is fused to an Archaerhodopsin-derived voltage sensor. Voltage-induced shifts in the absorption spectrum of the rhodopsin lead to voltage-dependent nonradiative quenching of the appended fluorescent protein. Through a library screen, we identified linkers and fluorescent protein combinations which reported neuronal action potentials in cultured rat hippocampal neurons with a single-trial signal-to-noise ratio from 6.6 to 11.6 in a 1 kHz imaging bandwidth at modest illumination intensity. The freedom to choose a voltage indicator from an array of colors facilitates multicolor voltage imaging, as well as combination with other optical reporters and optogenetic actuators.

Zou, Peng; Douglass, Adam D; Hochbaum, Daniel R; Brinks, Daan; Werley, Christopher A; Harrison, D Jed; Campbell, Robert E; Cohen, Adam E

2014-01-01T23:59:59.000Z

325

Nanowire-based ternary transistor by threshold-voltage manipulation  

SciTech Connect (OSTI)

We report on a ternary device consisting of two nanowire channels that have different threshold voltage (V{sub th}) values and show that three current stages can be produced. A microscale laser-beam shot was utilized to selectively anneal the nanowire channel area to be processed, and the amount of V{sub th} shift could be controlled by adjusting the laser wavelength. Microscale laser annealing process could control V{sub th} of the individual nanowire transistors while maintaining the other parameters the constant, such as the subthreshold slope, on–off current ratio, and mobility. This result could provide a potential for highly integrated and high-speed ternary circuits.

Han, Junebeom; Lim, Taekyung; Bong, Jihye; Seo, Keumyoung; Ju, Sanghyun, E-mail: shju@kgu.ac.kr [Department of Physics, Kyonggi University, Suwon, Gyeonggi-Do 443-760 (Korea, Republic of); Kim, Sunkook [Department of Electronics and Radio Engineering, Kyung Hee University, Yongin, Gyeonggi-Do 446-701 (Korea, Republic of)

2014-04-07T23:59:59.000Z

326

Probabilistic Vulnerability Assessment Based on Power Flow and Voltage Distribution  

SciTech Connect (OSTI)

Risk assessment of large scale power systems has been an important problem in power system reliability study. Probabilistic technique provides a powerful tool to solve the task. In this paper, we present the results of a study on probabilistic vulnerability assessment on WECC system. Cumulant based expansion method is applied to obtain the probabilistic distribution function (PDF) and cumulative distribution function (CDF) of power flows on transmission lines and voltage. Overall risk index based on the system vulnerability analysis is calculated using the WECC system. The simulation results based on WECC system is used to demonstrate the effectiveness of the method. The methodology can be applied to the risk analysis on large scale power systems.

Ma, Jian; Huang, Zhenyu; Wong, Pak C.; Ferryman, Thomas A.

2010-04-30T23:59:59.000Z

327

Voltage flicker prediction for two simultaneously operated ac arc furnaces  

SciTech Connect (OSTI)

An EMTP-based arc furnace model was developed for evaluation of flicker concerns associated with supplying a large integrated steel mill as they go from one to two furnace operation and as system changes are implemented that will affect the short circuit capacity at the 230 kV power supply substation. The model includes a dynamic arc representation which is designed to be characteristic of the initial portions of the melt cycle when the arc characteristics are the most variable (worst flicker conditions). The flicker calculations are verified using previous measurements with one furnace operation. Flicker simulations were then performed to evaluate a variety of different possible system strengths with both one and two furnaces in operation. The primary flicker measure used for this study is the unweighted rms value of the fluctuation envelope, expressed as a percentage of the rms line-to-ground voltage magnitude.

Tang, L. [ABB Power T and D Co., Inc., Raleigh, NC (United States)] [ABB Power T and D Co., Inc., Raleigh, NC (United States); Kolluri, S. [Entergy Services, New Orleans, LA (United States)] [Entergy Services, New Orleans, LA (United States); McGranaghan, M.F. [Electrotek Concepts, Inc., Knoxville, TN (United States)] [Electrotek Concepts, Inc., Knoxville, TN (United States)

1997-04-01T23:59:59.000Z

328

Voltage spike detection in high field superconducting accelerator magnets  

SciTech Connect (OSTI)

A measurement system for the detection of small magnetic flux changes in superconducting magnets, which are due to either mechanical motion of the conductor or flux jump, has been developed at Fermilab. These flux changes are detected as small amplitude, short duration voltage spikes, which are {approx}15mV in magnitude and lasts for {approx}30 {micro}sec. The detection system combines an analog circuit for the signal conditioning of two coil segments and a fast data acquisition system for digitizing the results, performing threshold detection, and storing the resultant data. The design of the spike detection system along with the modeling results and noise analysis will be presented. Data from tests of high field Nb{sub 3}Sn magnets at currents up to {approx}20KA will also be shown.

Orris, D.F.; Carcagno, R.; Feher, S.; Makulski, A.; Pischalnikov, Y.M.; /Fermilab

2004-12-01T23:59:59.000Z

329

Effect of high-voltage nanosecond pulses on complex plasmas  

SciTech Connect (OSTI)

Influence of high-voltage (1-11 kV) pulses of nanosecond (20 ns) duration on microparticles levitating in a rf plasma is studied. It is shown that the pulses produce significant influence on the plasma, causing perturbations with the relaxation time of the order of 10{sup -4} s. This time is sufficient for the microparticle to acquire significant kinetic energy. Application of repetitive pulses leads to the vertical oscillations of the microparticles. Clusters, consisting of small number of microparticles, exhibit parametric instabilities of horizontal modes under the effect of repetitive pulses. It was shown that the parametric instability is caused by the vertical oscillations of the microparticles in the nonuniform environment of the sheath.

Pustylnik, M. Y.; Ivlev, A. V.; Thomas, H. M.; Morfill, G. E. [Max-Planck-Institut fuer Extraterrestrische Physik, Giessenbachstrasse, 85741 Garching (Germany); Vasilyak, L. M.; Vetchinin, S. P.; Polyakov, D. N.; Fortov, V. E. [Joint Institute for High Temperatures, Russian Academy of Sciences, Izhorskaya 13/19, 125412 Moscow (Russian Federation)

2009-11-15T23:59:59.000Z

330

High-speed, sub-pull-in voltage MEMS switching.  

SciTech Connect (OSTI)

We have proposed and demonstrated MEMS switching devices that take advantage of the dynamic behavior of the MEMS devices to provide lower voltage actuation and higher switching speeds. We have explored the theory behind these switching techniques and have demonstrated these techniques in a range of devices including MEMS micromirror devices and in-plane parallel plate MEMS switches. In both devices we have demonstrated switching speeds under one microsecond which has essentially been a firm limit in MEMS switching. We also developed low-loss silicon waveguide technology and the ability to incorporate high-permittivity dielectric materials with MEMS. The successful development of these technologies have generated a number of new projects and have increased both the MEMS switching and optics capabilities of Sandia National Laboratories.

Spahn, Olga Blum; Brewer, Steven; Olsson, Roy H.; Bogart, Gregory R.; Luck, David L.; Watts, Michael R.; Shaw, Michael J.; Nielson, Gregory N.; Resnick, Paul James; Tigges, Christopher P.; Grossetete, Grant David

2008-01-01T23:59:59.000Z

331

High-voltage atmospheric breakdown across intervening rutile dielectrics.  

SciTech Connect (OSTI)

This report documents work conducted in FY13 on electrical discharge experiments performed to develop predictive computational models of the fundamental processes of surface breakdown in the vicinity of high-permittivity material interfaces. Further, experiments were conducted to determine if free carrier electrons could be excited into the conduction band thus lowering the effective breakdown voltage when UV photons (4.66 eV) from a high energy pulsed laser were incident on the rutile sample. This report documents the numerical approach, the experimental setup, and summarizes the data and simulations. Lastly, it describes the path forward and challenges that must be overcome in order to improve future experiments for characterizing the breakdown behavior for rutile.

Williamson, Kenneth Martin; Simpson, Sean; Coats, Rebecca Sue; Jorgenson, Roy Eberhardt; Hjalmarson, Harold Paul; Pasik, Michael Francis

2013-09-01T23:59:59.000Z

332

System and method for floating-substrate passive voltage contrast  

DOE Patents [OSTI]

A passive voltage contrast (PVC) system and method are disclosed for analyzing ICs to locate defects and failure mechanisms. During analysis a device side of a semiconductor die containing the IC is maintained in an electrically-floating condition without any ground electrical connection while a charged particle beam is scanned over the device side. Secondary particle emission from the device side of the IC is detected to form an image of device features, including electrical vias connected to transistor gates or to other structures in the IC. A difference in image contrast allows the defects or failure mechanisms be pinpointed. Varying the scan rate can, in some instances, produce an image reversal to facilitate precisely locating the defects or failure mechanisms in the IC. The system and method are useful for failure analysis of ICs formed on substrates (e.g. bulk semiconductor substrates and SOI substrates) and other types of structures.

Jenkins, Mark W. (Albuquerque, NM); Cole, Jr., Edward I. (Albuquerque, NM); Tangyunyong, Paiboon (Albuquerque, NM); Soden, Jerry M. (Placitas, NM); Walraven, Jeremy A. (Albuquerque, NM); Pimentel, Alejandro A. (Albuquerque, NM)

2009-04-28T23:59:59.000Z

333

Summary of multiterminal high-voltage direct current transmission technology  

SciTech Connect (OSTI)

This report summarizes the present state of multiterminal (MT) high-voltage direct current (HVDC) power transmission. The purpose is to reassess the need for HVDC circuit breakers and to identify needed research for MT HVDC. The fundamentals of this technology are presented, and previous research and development is reviewed. Although no MT HVDC systems have yet been built, many concepts have been proposed. Some require a dc breaker, and others do not. Both options have advantages and disadvantages for various applications, so the selection will depend on the proposed application. Research is needed to define operating characteristics of various MT HVDC systems. In some applications, dc breakers will be useful, so research into HVDC interruption should continue. Also, dc fault detection and control algorithms for MT systems should be studied.

Biggs, R.B.; Jewell, W.T.

1984-05-01T23:59:59.000Z

334

Sacramento Area Voltage Support Final Environmental Impact Statement  

SciTech Connect (OSTI)

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the National Environmental Policy Act (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: (1) Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; (2) Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and (3) Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2003-09-19T23:59:59.000Z

335

Sacramento Area Voltage Support Draft Environmental Impact Statement  

SciTech Connect (OSTI)

The Western Area Power Administration's Central Valley Project transmission system forms an integral part of the interconnected Sacramento area transmission grid. Western is contractually responsible to oversee that the system is operated in accordance with strict reliability standards. Growth in the greater Sacramento, California area and power imported from generation outside the region, have increased the demand on the interconnected electric transmission system, leading to transmission system overloads and reducing the reliability and security of the area power system. Western has prepared this Sacramento Area Voltage Support (SVS) Draft Environmental Impact Statement (EIS) in compliance with Federal laws, regulations and guidelines, principally the ''National Environmental Policy Act'' (NEPA). This Draft EIS evaluates the potential environmental effects of physical improvements to the area's power system. Enhancements are needed to improve system reliability and provide voltage support for the Sacramento area. The results of public scoping meetings, workshops, meetings with agencies, and earlier studies by Western and area utilities helped to develop a range of alternatives for analysis. The Proposed Action involves: Constructing a new double-circuit, 230-kV transmission line paralleling the existing double-circuit, 230-kV line from the O'Banion Substation to the Elverta Substation; Realigning a portion of the existing Cottonwood-Roseville single-circuit, 230-kV transmission line north of Elverta Substation; and Reconductoring the existing double-circuit, 230-kV transmission line from the Elverta Substation to the Tracy Substation. Public Hearings on the Draft EIS will be held between December 9-12, 2002. Comments on this Draft EIS are encouraged and should be sent to Ms. Loreen McMahon (above). Comments must be received by December 30, 2002.

N /A

2002-11-15T23:59:59.000Z

336

A new technique to reject dc-link voltage ripple in PWM inverters  

E-Print Network [OSTI]

to acknowledge the support of my husband and parents. TA. BLE OF CONTENTS CHAPTER I INTRODUCTION Page I. l Inverter Power Supplies 1. 2 Output Voltage Control 1. 2. 1 Control Of Voltage Supplied To The Inverter I. 2. 2 Control Of Voltage Within... and output of Stage 3 78 34 Exact solution of the switching angle trajectories for harmonic elimination with voltage control (M). 85 CHAPTER I INTRODUCTION Finding ways to control the flow of electricity has been a. goal of inventors and scientists...

Shireen, Wajiha

1990-01-01T23:59:59.000Z

337

The design of an A-C voltage regulator using a Wein Bridge detector  

E-Print Network [OSTI]

equipment, which in turn demands a mox'e closely regulated power supply. In satisfying these demands there have been many kinds of voltage regulators designed, constructed, and needs A voltage regulator oonsists essentially of two pax'ts, the "detectox...-V, 424-8, 470 3, 499-503 1950 4. Patchett, G. N. , "The Theory of Nonlinear Bridge Circuit Applied to Voltage Stabilizers, " J. I . E. E . , Vol. 93, Pt. III, p. 18 (1948). 5. Choudbury, J. K. t Das Gupta, S. C. , and Sen, P. C, , "An A-C Voltage...

Brown, Richard True

2012-06-07T23:59:59.000Z

338

High voltage bus and auxiliary heater control system for an electric or hybrid vehicle  

DOE Patents [OSTI]

A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

Murty, Balarama Vempaty (West Bloomfield, MI)

2000-01-01T23:59:59.000Z

339

February 2008 Rev 21 1/49 Very low drop voltage regulators with inhibit  

E-Print Network [OSTI]

. In the three terminal configuration the device has the same electrical performance, but is fixed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4 Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Figure 4. Dropout voltage vs output current

Berns, Hans-Gerd

340

Integration of offshore wind farms through High Voltage Direct Current networks.  

E-Print Network [OSTI]

??The integration of offshore wind farms through Multi Terminal DC (MTDC) networks into the GB network was investigated. The ability of Voltage Source Converter (VSC)… (more)

Livermore, Luke

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Solid State NMR Studies and Local Structure of Voltage Fade Materials  

Broader source: Energy.gov (indexed) [DOE]

with the Voltage Fade Team Michael Slater, Jason Croy, Kevin Gallagher, Christopher Johnson, Yang Ren DOE Vehicle Technologies Program Annual Merit Review Arlington, VA May 13 -...

342

Consideration of 34. 5 KV as an in-plant voltage for a large industrial user  

SciTech Connect (OSTI)

Traditionally, the in-plant distribution voltage for a large refinery or petrochemical complex has been 13.8 kV. Selection of this voltage level was dictated primarily by economic factors, simply because in most cases the magnitude of the loads or the lengths of the feeders did not produce sufficient savings to compensate for the costlier higher voltage switchgear. This paper presents some engineering and cost considerations for distribution at 34.5 kV and attempts to show that this voltage level is both economically and technically feasible for large electrical systems.

Niculescu, T.D.; Regan, R.R.

1983-09-01T23:59:59.000Z

343

E-Print Network 3.0 - active load voltage Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Page: << < 1 2 3 4 5 > >> 41 Performance Analysis of a Hybrid Asymmetric Multilevel Inverter for High Voltage Active Power Filter Applications Summary: Performance Analysis of a...

344

Theory and practice of dynamic voltage/frequency scaling in the high performance computing environment.  

E-Print Network [OSTI]

?? This dissertation provides a comprehensive overview of the theory and practice of Dynamic Voltage/Frequency Scaling (DVFS) in the High Performance Computing (HPC) environment. We… (more)

Rountree, Barry Louis

2010-01-01T23:59:59.000Z

345

Electric Field Calculations on Dry-Type Medium Voltage Current Transformers.  

E-Print Network [OSTI]

??This research presents potential and electric field calculations on medium voltage (MV) epoxy insulated outdoor current transformers (CTs) using a numeri-cal calculation approach. Two designs… (more)

Lakshmichand Jain, Sandeep Kumar

2012-01-01T23:59:59.000Z

346

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage...  

Broader source: Energy.gov (indexed) [DOE]

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage Princeton Power Systems (TRL 5 6...

347

A LOW POWER SCHEDULING SCHEME WITH RESOURCES OPERATING AT MULTIPLE VOLTAGES  

E-Print Network [OSTI]

A LOW POWER SCHEDULING SCHEME WITH RESOURCES OPERATING AT MULTIPLE VOLTAGES Ali Manzak and Chaitali Tempe, AZ 85287­5706 istanbul@asu.edu, chaitali@asu.edu ABSTRACT This paper presents a new resource the resources operate at multi­ ple voltages. The scheduling scheme is list based. In each control cycle

Kambhampati, Subbarao

348

Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power System  

E-Print Network [OSTI]

Importance of the Equlibrium Node in Preventing the Voltage Collapse Occurs in the Wind Power collapse will occurs in a wind power system is discussed next. The method of power flow calculation is the specific analysis of a given simplified wind power system. Keywords--voltage collapse; Newton

Lavaei, Javad

349

Voltage Control of Distribution Networks with Distributed Generation using Reactive Power  

E-Print Network [OSTI]

Voltage Control of Distribution Networks with Distributed Generation using Reactive Power to control voltage of distribution networks with DG using reactive power compensation approach. In this paper profile within the specified limits, it is essential to regulate the reactive power of the compensators

Pota, Himanshu Roy

350

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal Dutta  

E-Print Network [OSTI]

Meter Any Wire, Anywhere by Virtualizing the Voltage Channel Thomas Schmid, David Culler, Prabal}@eecs.umich.edu culler@cs.berkeley.edu Abstract AC power meters require both voltage and current to be sampled physical proximity and fed into a single power metering de- vice. In this paper, we explore the viability

Dutta, Prabal

351

Mitigation of Voltage and Current Harmonics in Grid-Connected Microgrids  

E-Print Network [OSTI]

Mitigation of Voltage and Current Harmonics in Grid-Connected Microgrids Mehdi Savaghebi1 , Josep M-connected microgrids. Two modes of compensation are considered, i.e. voltage and current compensation modes-electronic interface converter to the utility grid or microgrid. Microgrid is a local grid consisting of DGs, energy

Vasquez, Juan Carlos

352

Wind Farm Reactive Support and Voltage Control Daniel F. Opila Abdi M. Zeynu Ian A. Hiskens  

E-Print Network [OSTI]

Wind Farm Reactive Support and Voltage Control Daniel F. Opila Abdi M. Zeynu Ian A. Hiskens Abstract--Wind farms typically contain a variety of voltage control equipment including tap or wind farm; it is desirable to treat all the equipment as an integrated system rather than independent

Hiskens, Ian A.

353

Supply Voltage Degradation Aware Analytical Placement Andrew B. Kahng Bao Liu Qinke Wang  

E-Print Network [OSTI]

% performance degradation, and the effect is super-linear [22]. Therefore, power/ground Work partially supported along a supply cur- rent path, and (2) adding large decoupling capacitors close to supply voltage supply voltage drop). For high frequency de- signs, a number of decoupling capacitors need to be added

Liu, Bao

354

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents [OSTI]

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components.

Duckworth, Douglas C. (Knoxville, TN); Marcus, R. Kenneth (Clemson, SC); Donohue, David L. (Vienna, AT); Lewis, Trousdale A. (Oak Ridge, TN)

1994-01-01T23:59:59.000Z

355

Radio-frequency powered glow discharge device and method with high voltage interface  

DOE Patents [OSTI]

A high voltage accelerating potential, which is supplied by a high voltage direct current power supply, is applied to the electrically conducting interior wall of an RF powered glow discharge cell. The RF power supply desirably is electrically grounded, and the conductor carrying the RF power to the sample held by the probe is desirably shielded completely excepting only the conductor's terminal point of contact with the sample. The high voltage DC accelerating potential is not supplied to the sample. A high voltage capacitance is electrically connected in series between the sample on the one hand and the RF power supply and an impedance matching network on the other hand. The high voltage capacitance isolates the high DC voltage from the RF electronics, while the RF potential is passed across the high voltage capacitance to the plasma. An inductor protects at least the RF power supply, and desirably the impedance matching network as well, from a short that might occur across the high voltage capacitance. The discharge cell and the probe which holds the sample are configured and disposed to prevent the probe's components, which are maintained at ground potential, from bridging between the relatively low vacuum region in communication with the glow discharge maintained within the cell on the one hand, and the relatively high vacuum region surrounding the probe and cell on the other hand. The probe and cell also are configured and disposed to prevent the probe's components from electrically shorting the cell's components. 11 figures.

Duckworth, D.C.; Marcus, R.K.; Donohue, D.L.; Lewis, T.A.

1994-06-28T23:59:59.000Z

356

LM386 Low Voltage Audio Power Amplifier Literature Number: SNAS545A  

E-Print Network [OSTI]

LM386 LM386 Low Voltage Audio Power Amplifier Literature Number: SNAS545A #12;LM386 Low Voltage Audio Power Amplifier General Description The LM386 is a power amplifier designed for use in low volt, making the LM386 ideal for battery operation. Features n Battery operation n Minimum external parts n

Ravikumar, B.

357

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators  

E-Print Network [OSTI]

LM193/LM293/LM393/LM2903 Low Power Low Offset Voltage Dual Comparators General Description The LM clock timers; multivibrators and high voltage digital logic gates. The LM193 series was designed to directly interface with TTL and CMOS. When operated from both plus and minus power supplies, the LM193

Lanterman, Aaron

358

Journal of Power Sources 167 (2007) 1117 Voltage reversal during microbial fuel cell stack operation  

E-Print Network [OSTI]

Journal of Power Sources 167 (2007) 11­17 Voltage reversal during microbial fuel cell stack February 2007; accepted 9 February 2007 Available online 20 February 2007 Abstract Microbial fuel cells Elsevier B.V. All rights reserved. Keywords: Microbial fuel cell; Voltage reversal; Stack; Direct electron

2007-01-01T23:59:59.000Z

359

A New Bifurcation Analysis for Power System Dynamic Voltage Stability Studies  

E-Print Network [OSTI]

a specific system configuration and the operation condition. For a power system, the typical state variables are the time dependent generator voltages (For different generator models, the variables of generator voltages as the variables of the exciter, speed governor and so on; sometimes the dynamics of the load behavior will also

360

Impact of High Wind Penetration on the Voltage Profile of Distribution Systems  

E-Print Network [OSTI]

of wind generator the voltage of the system may become lower than acceptable voltage level due and wind generator is presented. Simulation results are given in Section III which shows the impact of high--In this paper, simulation results showing the effect of lower and higher penetration of distributed wind

Pota, Himanshu Roy

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Energy Aware Dynamic Voltage and Frequency Selection for Real-Time Systems with Energy Harvesting  

E-Print Network [OSTI]

Energy Aware Dynamic Voltage and Frequency Selection for Real-Time Systems with Energy Harvesting}@binghamton.edu Abstract In this paper, an energy aware dynamic voltage and frequency selection (EA-DVFS) algorithm energy and the harvested energy in a future duration. Specifically, if the system has sufficient energy

Qiu, Qinru

362

A static voltage-current characteristic for the low current DC arc  

E-Print Network [OSTI]

in the literature. Evaluated using the F-statistic, the best model, with a standard error of less than 3V , was a voltage source, opposed to the system voltage, dependent only on arc length. Current only influenced arc lifetime. Varc=l3v+l68v/inch*arc length...

Moores, Gregory Lee

1998-01-01T23:59:59.000Z

363

A theoretical study of the incandescent filament lamp performance under voltage flicker  

SciTech Connect (OSTI)

Incandescent filament lamp flicker, produced by voltage fluctuation, is a power quality problem that caused engineering concern since the onset of electrical illumination technology. The flicker phenomenon was analyzed and explained in early studies. Standards dealing with acceptable flicker levels are well known, nevertheless, today the discussion about flicker continues to be a top priority topic due to the fact that steady-state and transient voltage waveform distortion is a growing problem in low and medium voltage systems. In many situations voltage flicker is caused by subharmonics and interharmonics of voltage. Cycloconverters, welders and arc furnaces, eccentrically operating tools and integral cycle controlled power equipment are notorious for producing voltage flicker. The goal of this paper is to provide solid mathematical basis for the analytical modeling of incandescent filament lamp flicker when the voltage is nonsinusoidal. A mathematical model that enables the evaluation of the luminous flux modulation caused by noninteger harmonics (subharmonics and interharmonics) is presented. Three situations are detailed: square-wave voltage modulation, sinusoidal modulation and the case of noninteger harmonics with nearly contiguous frequencies.

Peretto, L. [Univ. of Bologna (Italy)] [Univ. of Bologna (Italy); Emanuel, A.E. [Worcester Polytechnic Inst., MA (United States)] [Worcester Polytechnic Inst., MA (United States)

1997-01-01T23:59:59.000Z

364

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions  

E-Print Network [OSTI]

Chapter 19. High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 19-1 High Voltage Insulation, Diagnostics and Energetic Electron and Photon Beam Interactions 1. DC Properties of Modern Filled Epoxy Insulation Academic and Research Staff Dr. Chathan Cooke Sponsor

365

VOLTAGE COLLAPSE AND TRANSIENT ENERGY FUNCTION ANALYSES OF AC/DC SYSTEMS  

E-Print Network [OSTI]

for power system dynamic models, including a third order representation of high voltage direct current (HVDC power limits, HVDC firing angle limits and voltage dependent current order limits (VDCOL) are shown the derivation of individual component Lyapunov functions for simplified models of HVDC links connected

Cañizares, Claudio A.

366

DECENTRALIZED VOLTAGE CONTROL TO MINIMIZE DISTRIBUTION LOSSES IN AN ISLANDED MICROGRID  

E-Print Network [OSTI]

power sources and energy storage systems such as batteries requires new power and voltage control-time voltage control algorithm that minimizes power losses for a microgrid supported by inverter based Microgrids can bring electricity power to rural communities or isolated military forward operation bases

Peng, Huei

367

A Smart Grid Voltage Sag Detector using an EEMD-Based Approach  

E-Print Network [OSTI]

A Smart Grid Voltage Sag Detector using an EEMD-Based Approach Yassine Amirat, Member, IEEE and Mohamed Benbouzid, Senior Member, IEEE Abstract--Smart grids have become a focal point in renewable energy detection in smart grids. Index Terms--Smart grid, voltage sag detection, power quality (PQ), ensemble

Paris-Sud XI, Université de

368

An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context  

E-Print Network [OSTI]

An Ensemble Empirical Mode Decomposition Approach for Voltage Sag Detection in a Smart Grid Context Yassine Amirat1,2 , Mohamed Benbouzid2 , Tianzhen Wang3 and Sylvie Turri2 Abstract­Smart grids have become, using the instantaneous power for voltage sags detection in smart grids. Copyright © 2013 Praise Worthy

Brest, Université de

369

Evaluation of Insulation Systems for the Optimal Design of High Voltage Pulse Transformers  

E-Print Network [OSTI]

This paper presents a study for the design of the insulation systems of high voltage pulse transformer based on experimental tests and numerical simulations. Data of high voltage tests on solid and liquid insulation materials are presented and discussed. The understanding of each part of the insulation is supported by electrostatic fields simulations.

Sylvain, Candolfi; Davide, Aguglia; Philippe, Viarouge; Jürgen, Biela; Jerome, Cros

2015-01-01T23:59:59.000Z

370

A New Thermal-Conscious System-Level Methodology for Energy-Efficient Processor Voltage Selection  

E-Print Network [OSTI]

A New Thermal-Conscious System-Level Methodology for Energy-Efficient Processor Voltage Selection a thermal-conscious system-level methodology to make energy-efficient voltage selection (VS) for nanometer), thermal resistance, are integrated and considered in our system models, and their impacts on energy

Wang, Yu

371

Switch contact device for interrupting high current, high voltage, AC and DC circuits  

DOE Patents [OSTI]

A high voltage switch contact structure capable of interrupting high voltage, high current AC and DC circuits. The contact structure confines the arc created when contacts open to the thin area between two insulating surfaces in intimate contact. This forces the arc into the shape of a thin sheet which loses heat energy far more rapidly than an arc column having a circular cross-section. These high heat losses require a dramatic increase in the voltage required to maintain the arc, thus extinguishing it when the required voltage exceeds the available voltage. The arc extinguishing process with this invention is not dependent on the occurrence of a current zero crossing and, consequently, is capable of rapidly interrupting both AC and DC circuits. The contact structure achieves its high performance without the use of sulfur hexafluoride.

Via, Lester C.; Witherspoon, F. Douglas; Ryan, John M.

2005-01-04T23:59:59.000Z

372

Low Voltage High Precision Spatial Light ModulatorsFinal Report  

SciTech Connect (OSTI)

The goal of this project was to make LLNL a leader in Spatial Light Modulators (SLMs) by developing the technology that will be needed by the next generation of SLMs. We would use new lower voltage actuators and bond those actuators directly to controlling circuitry to break the fundamental limitations that constrain current SLM technology. This three-year project was underfunded in the first year and not funded in the second year. With the funding that was available, we produced actuators and designs for the controlling circuitry that would have been integrated in the second year. Spatial light modulators (SLMs) are arrays of tiny movable mirrors that modulate the wave-fronts of light. SLMs can correct aberrations in incoming light for adaptive optics or modulate light for beam control, optical communication and particle manipulation. MicroElectroMechanical Systems (MEMS) is a technology that utilizes the microfabrication tools developed by the semiconductor industry to fabricate a wide variety of tiny machines. The first generation of MEMS SLMs have improved the functionality of SLMs while drastically reducing per pixel cost making arrays on the order of 1000 pixels readily available. These MEMS SLMs however are limited by the nature of their designs to be very difficult to scale above 1000 pixels and have very limited positioning accuracy. By co-locating the MEMS mirrors with CMOS electronics, we will increase the scalability and positioning accuracy. To do this we will have to make substantial advances in SLM actuator design, and fabrication.

Papavasiliou, A P

2005-02-09T23:59:59.000Z

373

High voltage power supply with modular series resonant inverters  

DOE Patents [OSTI]

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360.degree./n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit.

Dreifuerst, Gary R. (Livermore, CA); Merritt, Bernard T. (Livermore, CA)

1995-01-01T23:59:59.000Z

374

High voltage power supply with modular series resonant inverters  

DOE Patents [OSTI]

A relatively small and compact high voltage, high current power supply for a laser utilizes a plurality of modules containing series resonant half bridge inverters. A pair of reverse conducting thyristors are incorporated in each series resonant inverter module such that the series resonant inverter modules are sequentially activated in phases 360{degree}/n apart, where n=number of modules for n>2. Selective activation of the modules allows precise output control reducing ripple and improving efficiency. Each series resonant half bridge inverter module includes a transformer which has a cooling manifold for actively circulating a coolant such as water, to cool the transformer core as well as selected circuit elements. Conductors connecting and forming various circuit components comprise hollow, electrically conductive tubes such as copper. Coolant circulates through the tubes to remove heat. The conductive tubes act as electrically conductive lines for connecting various components of the power supply. Where it is desired to make electrical isolation breaks, tubes comprised of insulating material such as nylon are used to provide insulation and continue the fluid circuit. 11 figs.

Dreifuerst, G.R.; Merritt, B.T.

1995-07-18T23:59:59.000Z

375

An Annotated Bibliography of High-Voltage Direct-Current Transmission and Flexible AC Transmission (FACTS) Devices, 1991-1993.  

SciTech Connect (OSTI)

References are contained for HVDC systems, converter stations and components, overhead transmission lines, cable transmission, system design and operations, simulation of high voltage direct current systems, high-voltage direct current installations, and flexible AC transmission system (FACTS).

Litzenberger, Wayne; Lava, Val

1994-08-01T23:59:59.000Z

376

Princeton Power Systems (TRL 5 6 Component)- Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage  

Broader source: Energy.gov [DOE]

Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

377

Source of Sustained Voltage Difference between the Xylem of a Potted Ficus benjamina Tree and Its Soil  

E-Print Network [OSTI]

It has long been known that there is a sustained electrical potential (voltage) difference between the xylem of many plants

Mershin, Andreas

378

High-voltage crowbar protection for the large CDF axial drift chamber  

SciTech Connect (OSTI)

The Central Outer Tracker (COT) is a big cylindrical drift chamber that provides charged particle tracking for the Collider Detector at Fermilab experiment. To protect the COT, the large stored energy in the high voltage system needs to be removed quickly when a problem is sensed. For the high voltage switch, a special-order silicon-controlled-rectifier was chosen over more readily available integrated gate bipolar transistors because of layout and reliability questions. The considerations concerning the high voltage switch, the prototype performance, and the experience of more than two years of running are described.

Binkley, M.; Mukherjee, A.; Stuermer, W.; Wagner, R.L.; /Fermilab

2004-01-01T23:59:59.000Z

379

Characteristics of probe current harmonics based on various applied voltage waveforms in low temperature plasmas  

SciTech Connect (OSTI)

The characteristics of probe currents induced by applying various probe voltage waveforms, such as sinusoidal, sawtooth, square, and triangular, were investigated at a floating potential. It was found that the measured probe currents have many harmonics depending on the voltage waveforms. This was mainly due to the nonlinearity of the sheath in the plasma and was analyzed using the fast Fourier transform and a circuit model. By applying a triangular voltage waveform to a probe, plasma parameters such as electron temperature and plasma density could be obtained and compared to those of a single Langmuir probe and a floating harmonic method.

Kim, Young-Do; Kim, Yu-Sin; Lee, Hyo-Chang; Bang, Jin-Young; Chung, Chin-Wook [Department of Electrical Engineering, Hanyang University, 17 Heangdang-dong, Seongdong-gu, Seoul 133-791 (Korea, Republic of)

2011-03-15T23:59:59.000Z

380

High Power, High Voltage FETs in Linear Applications: A User's Perspective  

SciTech Connect (OSTI)

The specifications of the current crop of highpower, high-voltage field-effect transistors (FETs) can lure a designer into employing them in high-voltage DC equipment. Devices with extremely low on-resistance and very high power ratings are available from several manufacturers. However, our experience shows that high-voltage, linear operation of these devices at near-continuous duty can present difficult reliability challenges at stress levels well-below their published specifications. This paper chronicles the design evolution of a 600 volt, 8 ampere shunt regulator for use with megawatt-class radio transmitters, and presents a final design that has met its reliability criteria.

N. Greenough, E. Fredd, S. DePasquale

2009-09-21T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

PAPER ACCEPTED TO IEEE TRANSACTIONS ON POWER SYSTEMS, Nov. 2008 1 Reactive Power and Voltage Control in Distribution  

E-Print Network [OSTI]

PAPER ACCEPTED TO IEEE TRANSACTIONS ON POWER SYSTEMS, Nov. 2008 1 Reactive Power and Voltage) problem associated with reactive power and voltage control in distribution systems to minimize daily--Distribution systems, reactive power control, voltage control, optimal switching operations, mixed integer nonlinear

Cañizares, Claudio A.

382

Control of current and voltage oscillations in a short dc discharge making use of external auxiliary electrode  

E-Print Network [OSTI]

Control of current and voltage oscillations in a short dc discharge making use of external://rsi.aip.org/about/rights_and_permissions #12;REVIEW OF SCIENTIFIC INSTRUMENTS 83, 103502 (2012) Control of current and voltage oscillations October 2012) A dc discharge with a hot cathode is subject to current and voltage plasma oscillations

Kaganovich, Igor

383

SP 23.6: A 1.8GHz CMOS Voltage-Controlled Oscillator BehzadRazavi  

E-Print Network [OSTI]

SP 23.6: A 1.8GHz CMOS Voltage-Controlled Oscillator BehzadRazavi University of California, Los that limit the tuning range of monolithic LC voltage-controlled oscillators (VCOs), especially at low supply voltages, and introduces circuit techniques that alle- viate this problem. Incorporating such techniques

Razavi, Behzad

384

>300GHz Fixed-Frequency and Voltage-Controlled Fundamental Oscillators in an InP DHBT Process  

E-Print Network [OSTI]

>300GHz Fixed-Frequency and Voltage-Controlled Fundamental Oscillators in an InP DHBT Process, 93106, USA Abstract -- We report fundamental fixed-frequency and voltage-controlled oscillators bandwidth. Index Terms -- Millimeter-wave oscillators, voltage-controlled oscillators, MMIC oscillators. I

Rodwell, Mark J. W.

385

The role of linear and voltage-dependent ionic currents in the generation of slow wave oscillations  

E-Print Network [OSTI]

The role of linear and voltage-dependent ionic currents in the generation of slow wave oscillations voltages, re- spectively. Oscillations are created by inward currents driving the cell away from rest voltages and one outward current that repolarizes the cell. Such currents have traditionally been assumed

Bose, Amitabha

386

Effect of Trapping on the Critical Voltage for Degradation in GaN High Electron Mobility Transistors  

E-Print Network [OSTI]

conditions, UV illumination decreases the critical voltage for the onset of degradation in gate current in Ga traps in the fresh state. Keywords­ GaN HEMTs, critical voltage, degradation, UV illuminationEffect of Trapping on the Critical Voltage for Degradation in GaN High Electron Mobility

del Alamo, JesĂşs A.

387

Offset voltage of Schottky-collector silicon-on-glass vertical PNP's G. Lorito, L. K. Nanver and N. Nenadovi  

E-Print Network [OSTI]

Offset voltage of Schottky-collector silicon-on-glass vertical PNP's G. Lorito, L. K. Nanver and N and investigated with respect to the influence of the collector design on the offset voltage. With Schottky collector contacts the offset voltage can be made both very low (

Technische Universiteit Delft

388

Experiment for measurements of the gas breakdown statistics by ramp voltage pulses  

SciTech Connect (OSTI)

In the first part of this article the electronic automatic system for the measurements of dynamic breakdown voltages U{sub b} with linearly rising (ramp) pulses is presented. It generates the sequence of ramp pulses with subvoltage level U{sub sub}{approx_equal}0 during the relaxation time {tau} of the tube, and the ramp pulses start from the static breakdown voltage U{sub s}, thus enabling the correct study of electrical breakdowns and relaxation in gases. In the second part the measurements in argon with and without a voltage during the off period of the pulse are analyzed. The influence of the subvoltage on the mean value of the breakdown voltage U{sub b} as a function of the rise rate k, on the statistical U{sub b} distributions and on the afterglow kinetics is also discussed.

Markovic, V. Lj.; Stamenkovic, S. N.; Gocic, S. R.; Petrovic, Z. Lj. [Department of Physics, University of Nis, P.O. Box 224, 18001 Nis (Serbia and Montenegro); Institute of Physics, P.O. Box 68, 11080 Belgrade (Serbia and Montenegro)

2006-09-15T23:59:59.000Z

389

Analysis of asset health : an approach to monitoring and diagnostics for medium voltage circuit breakers  

E-Print Network [OSTI]

The Medium Voltage Electric Industry is a very conservative and risk adverse sector that has undergone very little change in the past 30 years when compared to other technologically dependent activities; this reality is ...

Corona, Erick (Erick Gustavo)

2013-01-01T23:59:59.000Z

390

A SCR SWITCHED CAPACITOR VOLTAGE REGULATOR FOR 150 kV NEUTRAL BEAM POWER SUPPLY  

E-Print Network [OSTI]

et a1. , "150-kV, 80-A Solid State Power Supply for Neutral100% solid state and provides 1% regulation at power levelssolid state high voltage re- gulator. The block diagram of the power

Milnes, K.A.

2011-01-01T23:59:59.000Z

391

E-Print Network 3.0 - affects voltage-gated calcium Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

, 1115-1118 3 Dolphin, A.C. (2003) b subunits of voltage-gated calcium channels. J. Bioenerg. Biomembr... . 35, 599-620 4 Van Petegem, F. et al. (2004) Structure of a complex...

392

Vehicle Technologies Office Merit Review 2014: High-Voltage Solid Polymer Batteries for Electric Drive Vehicles  

Broader source: Energy.gov [DOE]

Presentation given by Seeo, Inc. at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high-voltage solid polymer...

393

Voltage, Stability and Diffusion Barrier Differences between Sodium-ion and Lithium-ion Intercalation Materials  

E-Print Network [OSTI]

To evaluate the potential of Na-ion batteries, we contrast in this work the difference between Na-ion and Li-ion based intercalation chemistries in terms of three key battery properties—voltage, phase stability and diffusion ...

Ong, Shyue Ping

394

Spin-torque diode radio-frequency detector with voltage tuned resonance  

SciTech Connect (OSTI)

We report on a voltage-tunable radio-frequency (RF) detector based on a magnetic tunnel junction (MTJ). The spin-torque diode effect is used to excite and/or detect RF oscillations in the magnetic free layer of the MTJ. In order to reduce the overall in-plane magnetic anisotropy of the free layer, we take advantage of the perpendicular magnetic anisotropy at the interface between ferromagnetic and insulating layers. The applied bias voltage is shown to have a significant influence on the magnetic anisotropy, and thus on the resonance frequency of the device. This influence also depends on the voltage polarity. The obtained results are accounted for in terms of the interplay of spin-transfer-torque and voltage-controlled magnetic anisotropy effects.

Skowro?ski, Witold, E-mail: skowron@agh.edu.pl; Frankowski, Marek; Stobiecki, Tomasz [AGH University of Science and Technology, Department of Electronics, Al. Mickiewicza 30, 30-059 Kraków (Poland); Wrona, Jerzy [AGH University of Science and Technology, Department of Electronics, Al. Mickiewicza 30, 30-059 Kraków (Poland); Singulus Technologies, Kahl am Main 63796 (Germany); Ogrodnik, Piotr [Faculty of Physics, Warsaw University of Technology, ul. Koszykowa 75, 00-662 Warsaw (Poland); AGH University of Science and Technology, Department of Electronics, Al. Mickiewicza 30, 30-059 Kraków (Poland); Barna?, Józef [Faculty of Physics, Adam Mickiewicz University, ul. Umultowska 85, 61-614 Pozna? (Poland); Institute of Molecular Physics, Polish Academy of Sciences, Smoluchowskiego 17, 60-179 Pozna? (Poland)

2014-08-18T23:59:59.000Z

395

Current mode integrators and their applications in low-voltage high frequency CMOS signal processing  

E-Print Network [OSTI]

Low voltage CMOS fully differential integrators for high frequency continuous-time filters using current-mode techniques are presented.. Current mode techniques are employed to avoid the use of the floating differential pair, in order to achieve...

Smith, Sterling Lane

1993-01-01T23:59:59.000Z

396

Source of stray voltage and effect on cow health and performance  

SciTech Connect (OSTI)

In dairy cows, two distinct and important aspects of the interrelationship between stray voltage problems on the farm and dairy cow productivity can be identified. One is behavioral modification that increases in intensity when currents associated with neutral-to-earth voltages above .7 V find a pathway through the cow. The other is immediate endocrine response. Results of research are less clear on the current necessary for the latter to occur; it may require 8 mA or more. This implies, depending on the pathway and the cow's pathway resistance, that voltage difference between two cow contact points must exceed 3 V. Resistance of different cow pathways range from 350 to 1700 OMEGA. Milk production is more likely to be affected adversely when cows are subjected to shock patterns both intermittent and irregular. This paper identifies various sources of stray voltage problems and discusses appropriate procedures for correction.

Appleman, R.D.; Gustafson, R.J.

1985-01-01T23:59:59.000Z

397

Harmonic control of multiple-stator induction machines for voltage regulation  

E-Print Network [OSTI]

Small, one to a few horsepower, three-phase induction machines with three sets of electrically-isolated, magnetically-coupled stator winding circuits are described. A voltage inverter is developed and used to drive one set ...

Holloway, Jack Wade, 1980-

2004-01-01T23:59:59.000Z

398

Inverter Load Rejection Over-Voltage Testing: SolarCity CRADA...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Inverter Load Rejection Over-Voltage Testing SolarCity CRADA Task 1a Final Report A. Nelson, A. Hoke, and S. Chakraborty National Renewable Energy Laboratory J. Chebahtah, T. Wang,...

399

Coordination of Voltage and Frequency Feedback in Load-Frequency Control Capability of Wind Turbine  

E-Print Network [OSTI]

Coordination of Voltage and Frequency Feedback in Load-Frequency Control Capability of Wind Turbine-Frequency Control (LFC) is gradually shifted to Variable Speed Wind Turbines (VSWTs). In order to equip VSWT

Silva, Filipe Faria Da

400

High-Efficiency Multiple-Output DC-DC Conversion for Low-Voltage Systems  

E-Print Network [OSTI]

This versatile power converter controller provides dual outputs at a fixed switching frequency and can regulate either output voltage or target system delay (using an external -- filter). In the voltage regulation mode, the output voltage is monitored with an analog--digital (A/D) converter, and the feedback compensation network is implemented digitally. The generation of the pulsewidth modulation (PWM) signal is done with a hybrid delay line/counter approach, which saves power and area relative to previous implementations. Power devices are included on chip to create the two independently regulated output PWM signals. The key features of this design are its low-power dissipation, reconfigurability, use of either delay or voltage feedback, and multiple outputs.

Abram P. Dancy; Rajeevan Amirtharajah; Anantha P. Chandrakasan

2000-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Manufacturing challenges of optical current and voltage sensors for utility applications  

SciTech Connect (OSTI)

Measurement of voltages and currents in power transmission and distribution systems are critical to the electric utility industry for both revenue metering and reliability. Nonconventional instrument transformers based on intensity modulation of optical signals have been reported in the literature for more than 20 years. Recently described devices using passive bulk optical sensor elements include the Electro-Optic Voltage Transducer (EOVT) and Magneto-Optic Current Transducer (MOCT). These technologies offer substantial advantages over conventional instrument transformers in accuracy, optical isolation bandwidth, environmental compatibility, weight and size. This paper describes design and manufacturing issues associated with the EOVT and the Optical Metering Unit (OMU) recently introduced by ABB with field installation results presented for prototype units in the 345 kV and 420 kV voltage classes. The OMU incorporates an EOVT and MOCT to monitor the voltage and current on power transmission lines using a single free-standing device.

Yakymyshyn, C.P. [Montana State Univ., Bozeman, MT (United States). Dept. of Electrical and Computer Engineering; Brubaker, M.A. [Los Alamos National Lab., NM (United States); Johnston, P.M. [Johnston (Paul M.), Raleigh, NC (United States); Reinbold, C. [ABB High Voltage Switchgear, Greensburg, PA (United States)

1997-12-01T23:59:59.000Z

402

Analysis of three-phase rectifiers with constant-voltage loads  

E-Print Network [OSTI]

This work presents a quantitative analysis of the operating characteristics of three-phase diode bridge rectifiers with AC-side reactance and constant-voltage loads. We focus on the case where the AC-side currents vary ...

Caliskan, Vahe

403

A multilevel energy buffer and voltage modulator for grid-interfaced micro-inverters  

E-Print Network [OSTI]

Micro-inverters operating into the single-phase grid from solar photovoltaic (PV) panels or other low-voltage sources must buffer the twice-line-frequency variations between the energy sourced by the PV panel and that ...

Chen, Minjie

404

A Multilevel Energy Buffer and Voltage Modulator for Grid-Interfaced Microinverters  

E-Print Network [OSTI]

Microinverters operating into the single-phase grid from solar photovoltaic (PV) panels or other low-voltage sources must buffer the twice-line-frequency variations between the energy sourced by the PV panel and that ...

Chen, Minjie

405

Arc voltage distribution skewness as an indicator of electrode gap during vacuum arc remelting  

DOE Patents [OSTI]

The electrode gap of a VAR is monitored by determining the skewness of a distribution of gap voltage measurements. A decrease in skewness indicates an increase in gap and may be used to control the gap.

Williamson, Rodney L. (Albuquerque, NM); Zanner, Frank J. (Sandia Park, NM); Grose, Stephen M. (Glenwood, WV)

1998-01-01T23:59:59.000Z

406

Arc voltage distribution skewness as an indicator of electrode gap during vacuum arc remelting  

DOE Patents [OSTI]

The electrode gap of a VAR is monitored by determining the skewness of a distribution of gap voltage measurements. A decrease in skewness indicates an increase in gap and may be used to control the gap. 4 figs.

Williamson, R.L.; Zanner, F.J.; Grose, S.M.

1998-01-13T23:59:59.000Z

407

State-of-the-Art Fuel Cell Voltage Durability Status: Spring 2013 Composite Data Products  

SciTech Connect (OSTI)

This presentation from the U.S. Department of Energy's National Renewable Energy Laboratory includes composite data products (CDPs) produced in 2013 for state-of-the-art fuel cell voltage durability status.

Kurtz, J.; Sprik, S.; Saur, G.; Peters, M.; Post, M.; Ainscough, C.

2013-05-01T23:59:59.000Z

408

Hybrid integrated active antennas, voltage-controlled oscillators and switchable & tunable CPW-slotline filters  

E-Print Network [OSTI]

HYBRID INTEGRATED ACTIVE ANTENNAS, VOLTAGE-CONTROLLED OSCILLATORS AND SWITCHABLE & TUNABLE CPW-SLOTLINE FILTERS A Thesis by JULIO ANGEL NAVARRO Submitted to the Office of Graduate Studies of Texas ARM University in partial fulfillment... of the requirements for the degree of MASTER OF SCIENCE December 1990 Major Subject: Electrical Engineering HYBRID INTEGRATED ACTIVE ANTENNAS, VOLTAGE-CONTROLLED OSCILLATORS AND SWITCHABLE 2 TUNABLE CPW-SLOTLINE FILTERS A Thesis by JULIO ANGEL NAVARRO...

Navarro, Julio A

1990-01-01T23:59:59.000Z

409

Non-transposed, three phase transmission lines: a study of their effect on load voltages.  

E-Print Network [OSTI]

TRANSMISSION LINES A S'PJDY OF THEIR EFFECT ON LOAD VOLTAGES A Thesis By Robert Dean Chenoweth August 1951 NON-TRANSPOSED~ THREE PHASE TRANSMISSION LINES A STUDY OF THEIR EFFECT ON LOAD VOLTAGES A Thesis Submitted to the Faculty of the Agricultural... all large blocks of alternating current power are transmitted from the generating station to the load by means of three phase transmission lines. With present day equipment this method is economical and when ~ properly designed gives very...

Chenoweth, Robert Dean

1951-01-01T23:59:59.000Z

410

System Voltage Potential-Induced Degradation Mechanisms in PV Modules and Methods for Test  

SciTech Connect (OSTI)

Over the past decade, degradation and power loss have been observed in PV modules resulting from the stress exerted by system voltage bias. This is due in part to qualification tests and standards that do not adequately evaluate for the durability of modules to the long-term effects of high voltage bias experienced in fielded arrays. High voltage can lead to module degradation by multiple mechanisms. The extent of the voltage bias degradation is linked to the leakage current or culombs passed from the silicon active layer through the encapsulant and glass to the grounded module frame, which can be experimentally determined; however, competing processes make the effect non-linear and history-dependent. Appropriate testing methods and stress levels are described that demonstrate module durability to system voltage potential-induced degradation (PID) mechanisms. This information, along with outdoor testing that is in progress, is used to estimate the acceleration factors needed to evaluate the durability of modules to system voltage stress. Na-rich precipitates are observed on the cell surface after stressing the module to induce PID in damp heat with negative bias applied to the active layer.

Hacke, P.; Terwilliger, K.; Smith, R.; Glick, S.; Pankow, J.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-01-01T23:59:59.000Z

411

System Voltage Potential-Induced Degradation Mechanisms in PV Modules and Methods for Test: Preprint  

SciTech Connect (OSTI)

Over the past decade, degradation and power loss have been observed in PV modules resulting from the stress exerted by system voltage bias. This is due in part to qualification tests and standards that do not adequately evaluate for the durability of modules to the long-term effects of high voltage bias experienced in fielded arrays. High voltage can lead to module degradation by multiple mechanisms. The extent of the voltage bias degradation is linked to the leakage current or coulombs passed from the silicon active layer through the encapsulant and glass to the grounded module frame, which can be experimentally determined; however, competing processes make the effect non-linear and history-dependent. Appropriate testing methods and stress levels are described that demonstrate module durability to system voltage potential-induced degradation (PID) mechanisms. This information, along with outdoor testing that is in progress, is used to estimate the acceleration factors needed to evaluate the durability of modules to system voltage stress. Na-rich precipitates are observed on the cell surface after stressing the module to induce PID in damp heat with negative bias applied to the active layer.

Hacke, P.; Terwilliger, K.; Smith, R.; Glick, S.; Pankow, J.; Kempe, M.; Kurtz, S.; Bennett, I.; Kloos, M.

2011-07-01T23:59:59.000Z

412

The design, construction, and operation of long-distance high-voltage electricity transmission technologies.  

SciTech Connect (OSTI)

This report focuses on transmission lines, which operate at voltages of 115 kV and higher. Currently, the highest voltage lines comprising the North American power grid are at 765 kV. The grid is the network of transmission lines that interconnect most large power plants on the North American continent. One transmission line at this high voltage was built near Chicago as part of the interconnection for three large nuclear power plants southwest of the city. Lines at this voltage also serve markets in New York and New England, also very high demand regions. The large power transfers along the West Coast are generally at 230 or 500 kV. Just as there are practical limits to centralization of power production, there are practical limits to increasing line voltage. As voltage increases, the height of the supporting towers, the size of the insulators, the distance between conductors on a tower, and even the width of the right-of-way (ROW) required increase. These design features safely isolate the electric power, which has an increasing tendency to arc to ground as the voltage (or electrical potential) increases. In addition, very high voltages (345 kV and above) are subject to corona losses. These losses are a result of ionization of the atmosphere, and can amount to several megawatts of wasted power. Furthermore, they are a local nuisance to radio transmission and can produce a noticeable hum. Centralized power production has advantages of economies of scale and special resource availability (for instance, hydro resources), but centralized power requires long-distance transfers of power both to reach customers and to provide interconnections for reliability. Long distances are most economically served at high voltages, which require large-scale equipment and impose a substantial footprint on the corridors through which power passes. The most visible components of the transmission system are the conductors that provide paths for the power and the towers that keep these conductors at a safe distance from each other and from the ground and the natural and built environment. Common elements that are generally less visible (or at least more easily overlooked) include the maintained ROW along the path of the towers, access roads needed for maintenance, and staging areas used for initial construction that may be restored after construction is complete. Also visible but less common elements along the corridor may include switching stations or substations, where lines of similar or different voltages meet to transfer power.

Molburg, J. C.; Kavicky, J. A.; Picel, K. C.

2008-03-03T23:59:59.000Z

413

Using Distributed Energy Resources to Supply Reactive Power for Dynamic Voltage Regulation  

SciTech Connect (OSTI)

Abstract Distributed energy (DE) resources are power sources located near load centers and equipped with power electronics converters to interface with the grid, therefore it is feasible for DE to provide reactive power (along with active power) locally for dynamic voltage regulation. In this paper, a synchronous condenser and a DE source with an inverter interface are implemented in parallel in a distribution system to regulate the local voltage. Developed voltage control schemes for the inverter and the synchronous condenser are presented. Experimental results show that both the inverter and the synchronous condenser can regulate the local voltage instantaneously although the dynamic response of the inverter is much faster than the synchronous condenser. In a system with multiple DEs performing local voltage regulation, the interaction of multiple DE at different locations under different load levels may have an impact to the control parameter setting for each individual DE control system. Future research is needed to find out the interaction of DEs to identify the optimal control parameter settings with the consideration of many factors such as system configuration, load variation, and so on

Xu, Yan [ORNL; Li, Fangxing [ORNL; Li, Huijuan [University of Tennessee, Knoxville (UTK); Rizy, D Tom [ORNL; Kueck, John D [ORNL

2008-01-01T23:59:59.000Z

414

An expert system for voltage control in a power system network  

SciTech Connect (OSTI)

This paper presents a prototype of an expert system for alleviation of voltage violations in the day-to-day operation of large power networks. Voltage control for varying load and generation conditions can be achieved by co-ordinated control of switchable shunt VAR compensating (SVC) devices and On load transformer taps (OLTC), while generator excitations are used in dynamic control of voltage profile. This paper deals with the development of an expert system for voltage corrections for base case and contingency conditions using switchable shunt reactive compensation and transformer tap settings. The performance of the expert system is compared with the conventional optimization technique of voltage control and concurrent results have been obtained. The proposed expert system has been tested with simulated conditions of a few practical power systems. Results obtained for a 24 bus EHV Indian power network have been included for illustration purpose. The expert system is found to be suitable for on-line application in Energy Control Center as the solution is obtained very fast.

Bansilal; Thukaram, D.; Parthasarathy, K. [Indian Inst. of Science, Bangalore (India). Dept. of Electrical Engineering

1995-12-31T23:59:59.000Z

415

A combined compensation method for the output voltage of an insulated core transformer power supply  

SciTech Connect (OSTI)

An insulated core transformer (ICT) power supply is an ideal high-voltage generator for irradiation accelerators with energy lower than 3 MeV. However, there is a significant problem that the structure of the segmented cores leads to an increase in the leakage flux and voltage differences between rectifier disks. A high level of consistency in the output of the disks helps to achieve a compact structure by improving the utilization of both the rectifier components and the insulation distances, and consequently increase the output voltage of the power supply. The output voltages of the disks which are far away from the primary coils need to be improved to reduce their inhomogeneity. In this study, by investigating and comparing the existing compensation methods, a new combined compensation method is proposed, which increases the turns on the secondary coils and employs parallel capacitors to improve the consistency of the disks, while covering the entire operating range of the power supply. This method turns out to be both feasible and effective during the development of an ICT power supply. The non-uniformity of the output voltages of the disks is less than 3.5% from no-load to full-load, and the power supply reaches an output specification of 350 kV/60 mA.

Yang, L.; Yang, J., E-mail: jyang@mail.hust.edu.cn; Liu, K. F.; Qin, B.; Chen, D. Z. [State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology, Wuhan 430074 (China)

2014-06-15T23:59:59.000Z

416

Design, conditioning, and performance of a high voltage, high brightness dc photoelectron gun with variable gap  

SciTech Connect (OSTI)

A new high voltage photoemission gun has been constructed at Cornell University which features a segmented insulator and a movable anode, allowing the cathode-anode gap to be adjusted. In this work, we describe the gun's overall mechanical and high voltage design, the surface preparation of components, as well as the clean construction methods. We present high voltage conditioning data using a 50 mm cathode-anode gap, in which the conditioning voltage exceeds 500 kV, as well as at smaller gaps. Finally, we present simulated emittance results obtained from a genetic optimization scheme using voltage values based on the conditioning data. These results indicate that for charges up to 100 pC, a 30 mm gap at 400 kV has equal or smaller 100% emittance than a 50 mm gap at 450 kV, and also a smaller core emittance, when placed as the source for the Cornell energy recovery linac photoinjector with bunch length constrained to be <3 ps rms. For 100 pC up to 0.5 nC charges, the 50 mm gap has larger core emittance than the 30 mm gap, but conversely smaller 100% emittance.

Maxson, Jared; Bazarov, Ivan; Dunham, Bruce; Dobbins, John; Liu, Xianghong; Smolenski, Karl [Cornell Laboratory for Accelerator-Based Sciences and Education, Cornell University, Ithaca, New York 14853 (United States)

2014-09-15T23:59:59.000Z

417

Fiber-optic voltage sensor with cladded fiber and evanescent wave variation detection  

DOE Patents [OSTI]

A fiber optic voltage sensor is described which includes a source of light, a reference fiber for receiving a known percentage of the light and an electrostrictive element having terminals across which is applied, a voltage to be measured. The electrostrictive element is responsive to the applied voltage to assume an altered physical state. A measuring fiber also receives a known percentage of light from the light source and is secured about the electrostrictive element. The measuring fiber is provided with a cladding and exhibits an evanescent wave in the cladding. The measuring fiber has a known length which is altered when the electrostrictive element assumes its altered physical state. A differential sensor is provided which senses the intensity of light in both the reference fiber and the measuring fiber and provides an output indicative of the difference between the intensities. 3 figs.

Wood, C.B.

1992-12-15T23:59:59.000Z

418

Testing of High Voltage Surge Protection Devices for Use in Liquid Argon TPC Detectors  

E-Print Network [OSTI]

In this paper we demonstrate the capability of high voltage varistors and gas discharge tube arrestors for use as surge protection devices in liquid argon time projection chamber detectors. The insulating and clamping behavior of each type of device is characterized in air (room temperature), and liquid argon (90~K), and their robustness under high voltage and high energy surges in cryogenic conditions is verified. The protection of vulnerable components in liquid argon during a 150 kV high voltage discharge is also demonstrated. Each device is tested for argon contamination and light emission effects, and both are constrained to levels where no significant impact upon liquid argon time projection chamber functionality is expected. Both devices investigated are shown to be suitable for HV surge protection applications in cryogenic detectors.

J. Asaadi; J. M. Conrad; S. Gollapinni; B. J. P. Jones; H. Jostlein; J. M. St. John; T. Strauss; S. Wolbers; J. Zennamo

2014-06-23T23:59:59.000Z

419

Optimizing performance per watt on GPUs in High Performance Computing: temperature, frequency and voltage effects  

E-Print Network [OSTI]

The magnitude of the real-time digital signal processing challenge attached to large radio astronomical antenna arrays motivates use of high performance computing (HPC) systems. The need for high power efficiency (performance per watt) at remote observatory sites parallels that in HPC broadly, where efficiency is an emerging critical metric. We investigate how the performance per watt of graphics processing units (GPUs) is affected by temperature, core clock frequency and voltage. Our results highlight how the underlying physical processes that govern transistor operation affect power efficiency. In particular, we show experimentally that GPU power consumption grows non-linearly with both temperature and supply voltage, as predicted by physical transistor models. We show lowering GPU supply voltage and increasing clock frequency while maintaining a low die temperature increases the power efficiency of an NVIDIA K20 GPU by up to 37-48% over default settings when running xGPU, a compute-bound code used in radio...

Price, D C; Barsdell, B R; Babich, R; Greenhill, L J

2014-01-01T23:59:59.000Z

420

Multilevel-Dc-Bus Inverter For Providing Sinusoidal And Pwm Electrical Machine Voltages  

DOE Patents [OSTI]

A circuit for controlling an ac machine comprises a full bridge network of commutation switches which are connected to supply current for a corresponding voltage phase to the stator windings, a plurality of diodes, each in parallel connection to a respective one of the commutation switches, a plurality of dc source connections providing a multi-level dc bus for the full bridge network of commutation switches to produce sinusoidal voltages or PWM signals, and a controller connected for control of said dc source connections and said full bridge network of commutation switches to output substantially sinusoidal voltages to the stator windings. With the invention, the number of semiconductor switches is reduced to m+3 for a multi-level dc bus having m levels. A method of machine control is also disclosed.

Su, Gui-Jia [Knoxville, TN

2005-11-29T23:59:59.000Z

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Design and validation of a high-voltage levitation circuit for electrostatic accelerometers  

SciTech Connect (OSTI)

A simple high-voltage circuit with a voltage range of 0 to 900 V and an open-loop bandwidth of 11 kHz is realized by using an operational amplifier and a MOSFET combination. The circuit is used for the levitation of a test mass of 71 g, suspended below the top-electrodes with a gap distance of 57 ?m, so that the performance of an electrostatic accelerometer can be tested on the ground. The translation noise of the accelerometer, limited by seismic noise, is about 4 × 10{sup ?8} m/s{sup 2}/Hz{sup 1/2} at 0.1 Hz, while the high-voltage coupling noise is one-order of magnitude lower.

Li, G.; Wu, S. C.; Zhou, Z. B.; Bai, Y. Z.; Hu, M.; Luo, J. [MOE Key Laboratory of Fundamental Physical Quantities Measurements, School of Physics, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China)] [MOE Key Laboratory of Fundamental Physical Quantities Measurements, School of Physics, Huazhong University of Science and Technology, Wuhan, Hubei 430074 (China)

2013-12-15T23:59:59.000Z

422

Interconnected High-Voltage Pulsed-Power Converters System Design for H? Ion Sources  

E-Print Network [OSTI]

This paper presents the design and experimental validations of a system of three new high-voltage (HV) pulsedpower converters for the H? sources. The system requires three pulsed voltages (50, 40, and 25 kV to ground) at 2-Hz repetition rate, for 700 ?s of usable flat-top. The solution presents ripplefree output voltages and minimal stored energy to protect the ion source from the consequences of arc events. Experimental results on the final full-scale prototype are presented. In case of short-circuit events, the maximal energy delivered to the source is in the Joule range. HV flat-top stability of 1% is experimentally achieved with a simple Proportional-Integral- Derivative regulation and preliminary tuned H? source (e.g., radio frequency control, gas injection, and so forth). The system is running since more than a year with no power converter failures and damage to the source.

Aguglia, D

2014-01-01T23:59:59.000Z

423

Partial discharge measurements on a high voltage direct current mass impregnated paper cable  

SciTech Connect (OSTI)

Partial discharge measurement has been a good tool for the quality assurance of cables under alternating voltage. With the growing interest in High Voltage Direct Current cables it seems therefore logical to extend this technique for use at direct voltage. The paper describes this technique as used on a HVDC cable with mass impregnated paper. The different phases of operation (no load, full load, cooling phase, etc.) are characterized by a different discharge behavior. Special attention is given to the dangerous cooling phase. Models have been developed which can explain the discharge patterns that were measured. This paper gives an insight in the electrical behavior of a HVDC cable with mass impregnated paper insulation.

Jeroense, M.J.P. [NKF KABEL B.V., Delft (Netherlands); Kreuger, F.H. [Delft Univ. of Technology (Netherlands)

1996-12-31T23:59:59.000Z

424

Nobody but You: Sensor Selection for Voltage Regulation in Smart Grid  

E-Print Network [OSTI]

The increasing availability of distributed energy resources (DERs) and sensors in smart grid, as well as overlaying communication network, provides substantial potential benefits for improving the power system's reliability. In this paper, the problem of sensor selection is studied for the MAC layer design of wireless sensor networks for regulating the voltages in smart grid. The framework of hybrid dynamical system is proposed, using Kalman filter for voltage state estimation and LQR feedback control for voltage adjustment. The approach to obtain the optimal sensor selection sequence is studied. A sub- optimal sequence is obtained by applying the sliding window algorithm. Simulation results show that the proposed sensor selection strategy achieves a 40% performance gain over the baseline algorithm of the round-robin sensor polling.

Mao, Rukun

2011-01-01T23:59:59.000Z

425

Static reactive power compensators for high-voltage power systems. Final report  

SciTech Connect (OSTI)

A study conducted to summarize the role of static reactive power compensators for high voltage power system applications is described. This information should be useful to the utility system planning engineer in applying static var systems (SVS) to high voltage as (HVAC) systems. The static var system is defined as a form of reactive power compensator. The general need for reactive power compensation in HVAC systems is discussed, and the static var system is compared to other devices utilized to provide reactive power compensation. Examples are presented of applying SVS for specific functions, such as the prevention of voltage collapse. The operating principles of commercially available SVS's are discussed in detail. The perormance and active power loss characteristics of SVS types are compared.

Not Available

1981-04-01T23:59:59.000Z

426

Unidirectional anisotropy in the spin pumping voltage in yttrium iron garnet/platinum bilayers  

SciTech Connect (OSTI)

Detailed measurements of the dc voltage generated in a thin Pt layer deposited on films of yttrium iron garnet (YIG) have been carried out to study the spin pumping effect produced by magnetostatic (MS) modes excited by a microwave field. In relatively thick YIG films the modes are far apart so that one can identify clearly the spin pumping voltage in V{sub SP} produced by each MS mode. We have discovered that when the sputter deposition of the thin Pt layer is made on the YIG film magnetized by a static magnetic field, V{sub SP} exhibits a strong unidirectional anisotropy.

Vilela-Leao, L. H.; Salvador, C.; Azevedo, A.; Rezende, S. M.

2011-09-05T23:59:59.000Z

427

Observation of pressure stimulated voltages in rocks using an electric potential sensor  

SciTech Connect (OSTI)

Recent interest in the electrical activity in rock and the use of electric field transients as candidates for earthquake precursors has led to studies of pressure stimulated currents in laboratory samples. In this paper, an electric field sensor is used to measure directly the voltages associated with these currents. Stress was applied as uniaxial compression to marble and granite at an approximately constant rate. In contrast with the small pressure stimulated currents previously measured, large voltage signals are reported. Polarity reversal of the signal was observed immediately before fracture for the marble, in agreement with previous pressure stimulated current studies.

Aydin, A.; Prance, R. J.; Prance, H.; Harland, C. J. [Centre for Physical Electronics and Quantum Technology, School of Engineering and Design, University of Sussex, Brighton BN1 9QT (United Kingdom)

2009-09-21T23:59:59.000Z

428

Method and apparatus for remote tube crevice detection by current and voltage probe resistance measurement  

DOE Patents [OSTI]

A method and apparatus for determining the extent of contact between an electrically conducting tube and an electrically conductive tubesheet surrounding the tube, based upon the electrical resistance of the tube and tubesheet. A constant current source is applied to the interior of the electrically conducting tube by probes and a voltmeter is connected between other probes to measure the voltage at the point of current injection, which is inversely proportional to the amount of contact between the tube and tubesheet. Namely, the higher the voltage measured by the voltmeter, the less contact between the tube and tubesheet. 4 figs.

Kikta, T.J.; Mitchell, R.D.

1992-11-24T23:59:59.000Z

429

High voltage capability electrical coils insulated with materials containing SF.sub.6 gas  

DOE Patents [OSTI]

A coil is made having a plurality of layers of adjacent metal conductor windings subject to voltage stress, where the windings have insulation therebetween containing a small number of minute disposed throughout its cross-section, where the voids are voids filled with SF.sub.6 gas to substitute for air or other gaseous materials in from about 60% to about 95% of the cross-sectional void volume in the insulation, thus incorporating an amount of SF.sub.6 gas in the cross-section of the insulation effective to substantially increase corona inception voltages.

Lanoue, Thomas J. (Muncie, IN); Zeise, Clarence L. (Penn Township, Allegheny County, PA); Wagenaar, Loren (Muncie, IN); Westervelt, Dean C. (Acme, PA)

1988-01-01T23:59:59.000Z

430

Improving Cooling System Immunity Supply Voltage Sags in Petroleum and Chemical Industries  

E-Print Network [OSTI]

links in automated processes. During a common voltage sag, the coils in these devices may de-energize long enough to cause the contacts to open and connected equipment to shut down. Recognizing this Achilles' heel of the process industry, some... not interfere with emergency-stop operations because it supports only the coil of a contactor or relay and allows the coil to de-energize when the voltage is removed. It is small and can be easily installed next to a relay, contactor, or motor starter...

Dorr, D. S.

431

Modeling and Verification of Distributed Generation and Voltage Regulation Equipment for Unbalanced Distribution Power Systems; Annual Subcontract Report, June 2007  

SciTech Connect (OSTI)

This report summarizes the development of models for distributed generation and distribution circuit voltage regulation equipment for unbalanced power systems and their verification through actual field measurements.

Davis, M. W.; Broadwater, R.; Hambrick, J.

2007-07-01T23:59:59.000Z

432

Impacts of Large-Scale Wind Generators Penetration on the Voltage Stability of Power Systems  

E-Print Network [OSTI]

development of wind energy tech- nology and the current world-wide status of grid-connected as well as standImpacts of Large-Scale Wind Generators Penetration on the Voltage Stability of Power Systems M. J systems and their dynamic behaviours to identify critical issues that limit the large-scale integration

Pota, Himanshu Roy

433

Intelligent Voltage and Reactive Power Control of Mini-Hydro Power Stations for Maximisation of Real  

E-Print Network [OSTI]

1 Intelligent Voltage and Reactive Power Control of Mini-Hydro Power Stations for Maximisation Control (APFC) modes. The ability to export active and reactive power from mini-hydro power generators electrical power generation from renewable resources. Additionally, the potential early retiral of central

Harrison, Gareth

434

Effect of Detailed Power System Models in Traditional and Voltage Stability Constrained  

E-Print Network [OSTI]

problems to improve the accuracy of the results. It is shown in [2] that reactive power limits play], [9], [10], it is demonstrated that reactive power limits play a significant role in voltage collapse of power systems. Therefore, particular attention is placed here to the modeling of reactive power limits

Cañizares, Claudio A.

435

Capacitor Voltage Control in a Cascaded Multilevel Inverter as a Static Var Generator  

E-Print Network [OSTI]

1 Capacitor Voltage Control in a Cascaded Multilevel Inverter as a Static Var Generator M. Li, J. N for a cascaded multilevel inverter to be used for static var compensation. Index Terms-- Multilevel Inverter, Static Var Generator (SVG), Cascade inverter. I. INTRODUCTION Multilevel inverters have gained much

Tolbert, Leon M.

436

Multi-objective Optimal Power Flows to Evaluate Voltage Security Costs in Power Networks  

E-Print Network [OSTI]

1 Multi-objective Optimal Power Flows to Evaluate Voltage Security Costs in Power Networks William Abstract-- In this paper, new optimal power flow (OPF) tech- niques are proposed based on multi- dard power flow models. The results obtained using the proposed mixed OPFs are compared and analyzed

Cañizares, Claudio A.

437

Low-voltage, low-power circuits for data communication systems  

E-Print Network [OSTI]

transconductance amplifier (OTA) based on transistors operating in triode region is used to achieve a large linear signal swing with low-voltage supplies. A common-mode (CM) control circuit that combines common-mode feedback (CMFB), common-mode feedforward (CMFF...

Chen, Mingdeng

2005-02-17T23:59:59.000Z

438

Organic thin film devices with stabilized threshold voltage and mobility, and method for preparing the devices  

DOE Patents [OSTI]

Organic thin film devices that included an organic thin film subjected to a selected dose of a selected energy of ions exhibited a stabilized mobility (.mu.) and threshold voltage (VT), a decrease in contact resistance R.sub.C, and an extended operational lifetime that did not degrade after 2000 hours of operation in the air.

Nastasi, Michael Anthony; Wang, Yongqiang; Fraboni, Beatrice; Cosseddu, Piero; Bonfiglio, Annalisa

2013-06-11T23:59:59.000Z

439

Energy Harvesting by Sweeping Voltage-Escalated Charging of a Reconfigurable Supercapacitor Array  

E-Print Network [OSTI]

Energy Harvesting by Sweeping Voltage-Escalated Charging of a Reconfigurable Supercapacitor Array charge pump to perform maximum power-transfer track- ing (MPTT) while charging a reservoir supercapacitor. The supercapacitors in the RSA can be dynamically configured for series or parallel topologies by means of a switch

Shinozuka, Masanobu

440

Comparison of the Different Circuits Used for Balancing the Voltage of Supercapacitors  

E-Print Network [OSTI]

1 Comparison of the Different Circuits Used for Balancing the Voltage of Supercapacitors: Studying Performance and Lifetime of Supercapacitors Yasser Diab, Pascal Venet, Gerard Rojat CEGELY UMR-CNRS 5005@cegely.univ-lyon1.fr Abstract--The main disadvantage of using supercapacitors in the field of energy storage systems

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Effects of applied voltages and dissolved oxygen on sustained power generation by microbial fuel cells  

E-Print Network [OSTI]

Effects of applied voltages and dissolved oxygen on sustained power generation by microbial fuel), Faculty of Advanced Technology, University of Glamorgan, Pontypridd RCT CF37 1DL, UK Oxygen intrusion chamber MFCs at the end of a cycle when the substrate is depleted. A slight increase in dissolved oxygen

442

Voltage Stability and Power Quality Issues of Wind Farm with Series Compensation  

E-Print Network [OSTI]

is replaced by a large wind power plant which can have adverse effects on the stability and dynamic natureVoltage Stability and Power Quality Issues of Wind Farm with Series Compensation T. F. Orchi in DIgSILENT PowerFactory environment. From the simulation results, it is found that using a SC with wind

Pota, Himanshu Roy

443

Reactive power management of distribution networks with wind generation for improving voltage stability  

E-Print Network [OSTI]

-loadability Reactive power margin Wind turbine a b s t r a c t This paper proposes static and dynamic VAR planningReactive power management of distribution networks with wind generation for improving voltage February 2013 Available online Keywords: Composite load Distributed generation D-STATCOM Q

Pota, Himanshu Roy

444

Electrical detection of spin pumping: dc voltage generated by ferromagnetic resonance at ferromagnet/nonmagnet contact  

E-Print Network [OSTI]

Electrical detection of spin pumping: dc voltage generated by ferromagnetic resonance We describe electrical detection of spin pumping in metallic nanostructures. In the spin pumping effect, a precessing ferromagnet attached to a normal metal acts as a pump of spin-polarized current

van der Wal, Caspar H.

445

Voltage-gated Ion Channels and Gating Modifier Toxins William A. Catterall,* Sandrine Cestle,  

E-Print Network [OSTI]

;2 Abstract Voltage-gated sodium, calcium, and potassium channels generate electrical signals required and a pore loop. Their pores are formed by the S5/S6 segments and the pore loop between them and are gated and participate in calcium signaling pathways in nonexcitable cells. Because of their importance in many aspects

Paris-Sud XI, Université de

446

HYBRID CONTROL OF DISTRIBUTED GENERATORS CONNECTED TO WEAK RURAL NETWORKS TO MITIGATE VOLTAGE VARIATION  

E-Print Network [OSTI]

thermal power plants will increase the total and proportion of capacity of Distributed Generation (DG@iee.org; Robin.Wallace@ed.ac.uk ABSTRACT Distributed generators are normally operated in automatic power factor-constrained bi- directional power flow may cause unacceptable voltage fluctuations that would cause generator

Harrison, Gareth

447

Amorphous silicon/polyaniline heterojunction solar cells: Fermi levels and open-circuit voltages  

E-Print Network [OSTI]

these open-circuit voltages are lower than for the best a-Si:H cells utilizing nanocrystalline Si or a reports on conducting polymer/ amorphous silicon (a-Si:H) structures [1­4] and conduct- ing polymer/crystalline silicon (c-Si) structures [5,6]. In this paper, we report our research on polyaniline (PANI)/a-Si:H

Schiff, Eric A.

448

Voltage grid support of DFIG wind turbines during grid faults Anca D. Hansen1  

E-Print Network [OSTI]

Voltage grid support of DFIG wind turbines during grid faults Anca D. Hansen1 , Gabriele Michalke2) wind turbines address primarily the design of DFIG wind turbine control with special focus on power strategy for DFIG wind turbines, which enhances the fault ride-through capability of DFIG wind turbines

449

Quadratic voltage profiles in lead acid cells during slow, steady processes  

E-Print Network [OSTI]

It is standard lore that the voltage profile varies linearly in space within the electrolyte of a lead acid cell under slow, steady discharge. However, this hypothesis has never been put to the test. A recent theory predicts a uniform, non...

Haaser, Robert Anthony

1999-01-01T23:59:59.000Z

450

Dual Low Voltage IC Based High and Low Side Yan Yin, Regan Zane  

E-Print Network [OSTI]

drivers are required in most switching power converters to provide on/off control of both ground referenced and floating switches. The drivers are required to provide sufficient current to the gates to meet and low-side gate drivers; dual low voltage ICs; capacitive coupling; charge pump I. INTRODUCTION High

451

The powerful high-voltage glow discharge electron gun and power unit on its base  

SciTech Connect (OSTI)

The technical and operational characteristics and features of powerful electron gun with cold cathodes on the basis of high-voltage glow discharge (HGD) are submitted. The systems, ensuring their work are described. Some results of operation and applications of these non-traditional electron guns are presented.

Chernov, V.A. [All-Russian Electrotechnical Institute, Moscow (Russian Federation)

1994-12-31T23:59:59.000Z

452

Voltage control of magnetic anisotropy in Fe films with quantum well states  

E-Print Network [OSTI]

The influence of a gate voltage on magnetic anisotropy is investigated in a thin Fe film epitaxially grown on a Ag(1,1,10) substrate and covered by MgO. Oscillations in step-induced magnetic anisotropy due to quantum well ...

Bauer, Uwe

453

CONCEPT OF PHASE-NOISE TUNING OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS  

E-Print Network [OSTI]

CONCEPT OF PHASE-NOISE TUNING OF BIPOLAR VOLTAGE-CONTROLLED OSCILLATORS Aleksandar Tasic and Wouter 9423 Fax: +31 (0)15 278 5922 E-mail: a.tasic|w.a.serdijn@its.tudelft.nl ABSTRACT So far, oscillators. As the communication channel is often subject to changes, the conditions under which the oscillator operates should

Serdijn, Wouter A.

454

Method for improving voltage regulation of batteries, particularly Li/FeS/sub 2/ thermal batteries  

DOE Patents [OSTI]

Batteries are improved, especially with respect to voltage regulation properties, by employing as anode and cathode compositions, those which fall in a thermodynamically invariant region of the metallurgical phase diagram of the combination of the constituent components. The invention is especially useful in the Li/FeS/sub 2/ system.

Godshall, N.A.

1986-06-10T23:59:59.000Z

455

Price Discovery in Dynamic Power Markets with Low-Voltage Distribution-Network Participants  

E-Print Network [OSTI]

-distribution network locational marginal prices; power flow; reactive power compensation; voltage control; distributed application to Electric Power [2, 3] dynamic Locational-Marginal-Price (LMP) based Wholesale Power Markets to clear markets and discover dynamic Locational Marginal Prices (LMPs) that promoted more efficient

Caramanis, Michael

456

Ca2 -dependent activation of Cl currents in Xenopus oocytes is modulated by voltage  

E-Print Network [OSTI]

Ca2 -dependent activation of Cl currents in Xenopus oocytes is modulated by voltage NICK CALLAMARAS, University of California Irvine, Irvine, California 92697-4550 Callamaras, Nick, and Ian Parker. Ca2 278: C667­C675, 2000.-- Ca2 -activated Cl currents (ICl,Ca) were examined using fluorescence confocal

Parker, Ian

457

PEV-Based Combined Frequency and Voltage Regulation for Smart Grid  

E-Print Network [OSTI]

by either adjusting supply or changing demand. While various demand side management programs have used benefit both users and utilities. Index Terms--Smart grid, plug-in electric vehicles, demand side management, reactive power compensation, ancillary ser- vices, frequency regulation, voltage regulation

Huang, Jianwei

458

Nonlinear DSTATCOM controller design for distribution network with distributed generation to enhance voltage stability  

E-Print Network [OSTI]

Nonlinear DSTATCOM controller design for distribution network with distributed generation Accepted 19 June 2013 Keywords: Distributed generation Distribution network DSATACOM Partial feedback linearization Voltage control a b s t r a c t This paper presents a nonlinear controller design for a DSTATCOM

Pota, Himanshu Roy

459

Mitigating Voltage Fade in Cathode Materials by Improving the Atomic Level Uniformity of Elemental Distribution  

SciTech Connect (OSTI)

Li-rich and Mn-rich (LMR) layered structured materials are very promising cathodes for high-energy lithium-ion batteries. However, their fundamental structure and voltage fading mechanisms are far from being well understood. Here we report the first evidence on the reduced voltage and energy fade of LMR cathode by improving the atomic level spatial distribution of the chemical species. LMR cathode (Li[Li0.2Ni0.2M0.6]O2) prepared by co-precipitation and sol-gel methods are dominated by R-3m phase and show significant Ni-segregation at the surface of the particles. They exhibit large voltage-fade and fast capacity degradation. In contrast, LMR cathode prepared by hydrothermal assisted method is dominated by C2/m phase and minimal Ni-segregation. It also demonstrates much smaller voltage-fade and excellent capacity retention. The fundamental correlation between the atomic level spatial distribution of the chemical species and the functional stability of the materials found in this work also guide the design of other functional materials with enhanced stabilities.

Zheng, Jianming; Gu, Meng; Genc, Arda; Xiao, Jie; Xu, Pinghong; Chen, Xilin; Zhu, Zihua; Zhao, Wenbo; Pullan, Lee; Wang, Chong M.; Zhang, Jiguang

2014-04-07T23:59:59.000Z

460

AN OPEN-CIRCUIT-VOLTAGE MODEL OF LITHIUM-ION BATTERIES FOR EFFECTIVE INCREMENTAL CAPACITY ANALYSIS  

E-Print Network [OSTI]

AN OPEN-CIRCUIT-VOLTAGE MODEL OF LITHIUM-ION BATTERIES FOR EFFECTIVE INCREMENTAL CAPACITY ANALYSIS electrochemical properties and aging status. INTRODUCTION With the widespread use of lithium-ion batteries the com- plex battery physical behavior during the lithium-ion intercalac- tion/deintercalation process

Peng, Huei

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Voltage control of emerging distribution systems with induction motor loads using robust LQG approach  

E-Print Network [OSTI]

, electricity is mainly produced by large generation plants, generally located near the primary energy sources has significant performance to improve the voltage profile of the distributed generation system & Sons, Ltd. key words: distributed generation; eigenvalue; H1 norm; induction motor; linear quadratic

Pota, Himanshu Roy

462

Gate Voltage Control of Oxygen Diffusion on Graphene Dr. Jorge O. Sofo  

E-Print Network [OSTI]

Gate Voltage Control of Oxygen Diffusion on Graphene Dr. Jorge O. Sofo Associate Professor conductivity (twice that of diamond). Due to Carbon's affinity for tetrahedral bonding, its surface is amenable atoms. Our research focuses on the attachment and diffusion of different atomic species to the surface

Bjřrnstad, Ottar Nordal

463

Currents' Physical Components (CPC) In Circuits with Nonsinusoidal Voltages and Currents  

E-Print Network [OSTI]

and transformer turn ratio is 1:1, the active power at the supply terminals is P = 115.1 kW, while the apparentCurrents' Physical Components (CPC) In Circuits with Nonsinusoidal Voltages and Currents Part 2 state of discussions on power phenomena, power definitions and compensation in three-phase three

Czarnecki, Leszek S.

464

An Energy-Efficient Scheduling Algorithm Using Dynamic Voltage Scaling for Parallel Applications on Clusters  

E-Print Network [OSTI]

1 An Energy-Efficient Scheduling Algorithm Using Dynamic Voltage Scaling for Parallel Applications clusters. In this paper, we propose an energy-efficient scheduling algorithm (TDVAS) using the dynamic in clusters is to make use of cutting- edge energy-efficient processors. This is because processors

Qin, Xiao

465

Electrical voltages and resistances measured to inspect metallic cased wells and pipelines  

DOE Patents [OSTI]

A cased well in the earth is electrically energized with A.C. current. Voltages are measured from three voltage measurement electrodes in electrical contact with the interior of the casing while the casing is electrically energized. In a measurement mode, A.C. current is conducted from a first current carrying electrode within the cased well to a remote second current carrying electrode located on the surface of the earth. In a calibration mode, current is passed from the first current carrying electrode to a third current carrying electrode located vertically at a different position within the cased well, where the three voltage measurement electrodes are located vertically in between the first and third current carrying electrodes. Voltages along the casing and resistances along the casing are measured to determine wall thickness and the location of any casing collars present so as to electrically inspect the casing. Similar methods are employed to energize a pipeline to measure the wall thickness of the pipeline and the location of pipe joints to electrically inspect the pipeline.

Vail, III, William Banning (Bothell, WA); Momii, Steven Thomas (Seattle, WA)

2001-01-01T23:59:59.000Z

466

Reducing the color shift of a multidomain vertical alignment liquid crystal display using dual threshold voltages  

E-Print Network [OSTI]

threshold voltages Ruibo Lu and Shin-Tson Wua College of Optics and Photonics, University of Central Florida region. As a result, the final gamma curve is a superposition of two different-shaped gamma curves coupled method and two thin-film-transistor TFT method, have been pro- posed to improve the gamma curve

Wu, Shin-Tson

467

Effects of Magnesium on Inactivation of the Voltage-gated Calcium Current in  

E-Print Network [OSTI]

Effects of Magnesium on Inactivation of the Voltage-gated Calcium Current in Cardiac Myocytes H-dependent inactivation can be modulated by changes in cytoplasmic Mg~+. INTRODUCTION Magnesium is an important constituent of the intracellular milieu. Despite the importance of magnesium as an essential cofactor

468

Role of bias voltage and tunneling current in the perpendicular displacements of freestanding graphene via scanning  

E-Print Network [OSTI]

graphene via scanning tunneling microscopy Peng Xu, Steven D. Barber, Matthew L. Ackerman, James Kevin measurements of freestanding graphene as a function of applied bias voltage and tunneling current setpoint, the graphene approaches the STM tip, while, on the other hand, when the tunneling current is increased

Thibado, Paul M.

469

Classification : Original Article VOLTAGE-GATED SODIUM CHANNELS POTENTIATE THE INVASIVE  

E-Print Network [OSTI]

- gated sodium channels in non-small-cell lung cancer cell lines. Functional voltage-gated sodium channels cancerous cell lines H23, H460 and Calu-1 possess functional sodium channels while normal and weakly metastatic cell lines do not. While all the cell lines expressed mRNA for numerous sodium channel isoforms

Boyer, Edmond

470

Resistance and current-voltage characteristics of individual superconducting NbSe2 nanowires  

SciTech Connect (OSTI)

Resistance and current-voltage characteristics of individual superconducting NbSe{sub 2} nanowires are investigated. In the current-voltage curves, a stairlike structure is observed, indicating the possible formation of phase-slip centers. A close examination of the current-voltage characteristic in a selected high quality NbSe{sub 2} nanowire with a diameter of 75 nm reveals that the characteristic voltages in the stairlike structure follow the BCS-like temperature dependence of superconducting gaps vanishing at T{sub C}. While the phase-slip center mechanism remains to be a plausible explanation of the observed features, an alternative model involving multigap Josephson tunneling is proposed to account for the BCS-like temperature dependence. From the BCS fits, two distinct superconducting gaps are extracted. Moreover, the critical current of the 75 nm nanowire at low temperatures as well as near T{sub C} can also be described by the Ambegaokar-Baratoff relation for multigap Josephson junctions. Our data suggest the possible observation of multiband superconductivity in NbSe{sub 2} and are in good agreement with the predictions of recent band structure and Fermi surface calculations on NbSe{sub 2}.

Zhou, Zhixian [ORNL; Jin, Rongying [ORNL; Eres, Gyula [ORNL; Mandrus, David [ORNL; Barzykin, Victor [University of Tennessee, Knoxville (UTK); Schlottmann, P. [Florida State University; Hor, Y.S. [Argonne National Laboratory (ANL); Xiao, X.L. [Argonne National Laboratory (ANL); Mitchell, J. F. [Argonne National Laboratory (ANL)

2007-01-01T23:59:59.000Z

471

An earth-isolated optically coupled wideband high voltage probe powered by ambient light  

E-Print Network [OSTI]

(2012) Optimized working conditions for a thermoelectric generator as a topping cycle for gas turbines J (2012) Feasibility study in application of forging waste heat on absorption cooling system J. Renewable-emitting diode that converts high voltage into an amplitude-modulated optical signal, which is then conveyed

Bellan, Paul M.

472

Clustering-Based Simultaneous Task and Voltage Scheduling for NoC Systems  

E-Print Network [OSTI]

-efficiency improvement. In this work, we propose a simultaneous task and voltage scheduling algorithm for energy minimization in NoC based designs. The energy-latency tradeoff is handled by Lagrangian relaxation. The core algorithm is a clustering based approach which...

Yang, Yu

2011-08-08T23:59:59.000Z

473

Realizing high-voltage thin film lateral bipolar transistors on SOI with a collector-tub  

E-Print Network [OSTI]

Realizing high-voltage thin film lateral bipolar transistors on SOI with a collector-tub Sukhendu-dimensional device simulation to examine the effect of a collector tub on the collector breakdown of the SOI based BJTs. This method involves creating a collector tub by etching the buried oxide followed by an n

Kumar, M. Jagadesh

474

RASRAFMEK-dependent oxidative cell death involving voltage-dependent anion channels  

E-Print Network [OSTI]

LETTERS RAS­RAF­MEK-dependent oxidative cell death involving voltage-dependent anion channels J. Fridman1 , Adam J. Wolpaw1 , Inese Smukste1 , John M. Peltier3 , J. Jay Boniface3 , Richard Smith that discriminate between the genetic makeup of normal cells and tumour cells are valuable for treating and under

Stockwell, Brent R.

475

Electrical voltages and resistances measured to inspect metallic cased wells and pipelines  

DOE Patents [OSTI]

A cased well in the earth is electrically energized with A.C. current. Voltages are measured from three voltage measurement electrodes in electrical contact with the interior of the casing while the casing is electrically energized. In a measurement mode, A.C. current is conducted from a first current carrying electrode within the cased well to a remote second current carrying electrode located on the surface of the earth. In a calibration mode, current is passed from the first current carrying electrode to a third current carrying electrode located vertically at a different position within the cased well, where the three voltage measurement electrodes are located vertically in between the first and third current carrying electrodes. Voltages along the casing and resistances along the casing are measured to determine wall thickness and the location of any casing collars present so as to electrically inspect the casing. Similar methods are employed to energize a pipeline to measure the wall thickness of the pipeline and the location of pipe joints to electrically inspect the pipeline.

Vail, III, William Banning (Bothell, WA); Momii, Steven Thomas (Seattle, WA)

2000-01-01T23:59:59.000Z

476

Voltage and frequency control of islanded microgrids: a plug-and-play approach  

E-Print Network [OSTI]

of Distributed Generation Units (DGUs). Local controllers regulate voltage and frequency at the Point of Common-sufficient microgrids composed by several Distributed Generation Units (DGUs) and designed to operate safely, ImGs bring distributed generation sources close to loads and allow power to be delivered to rural

Ferrari-Trecate, Giancarlo

477

Secondary Voltage Unbalance Compensation for Three-Phase Four-Wire Islanded Microgrids  

E-Print Network [OSTI]

as a cluster of distributed resources (DRs), i.e. distributed generation (DG), distributed storage (DSSecondary Voltage Unbalance Compensation for Three-Phase Four-Wire Islanded Microgrids Fen Tang four-wire islanded microgrid systems. It is implemented in the secondary control level of the microgrid

Vasquez, Juan Carlos

478

Small-Signal Modeling of a Three-Phase Isolated Inverter with Both Voltage and  

E-Print Network [OSTI]

with the introduction of modern power generating units such as wind and solar power plants. As these new energy sourcesSmall-Signal Modeling of a Three-Phase Isolated Inverter with Both Voltage and Frequency Droop Rolla, Missouri 65409 Abstract-- In conventional power system operation, droop control methods are used

Kimball, Jonathan W.

479

Durham University, School of Engineering, Low Voltage Micro-generation Laboratory  

E-Print Network [OSTI]

. The system can control the micro- source and ESU inverter interfaces in order to regulate active power flow for organisations looking to carry out the following types of work: · Testing new designs of low voltage power. Reactive power flow into and out of the energy storage system may also be controlled, Figure 4. Finally

Wirosoetisno, Djoko

480

BATTERY AWARE TASK SCHEDULING FOR A SYSTEM-ON-A-CHIP USING VOLTAGE/CLOCK SCALING  

E-Print Network [OSTI]

is closest to the [12]; however we use Li-Ion based battery model of [13] to guide the schedul- ing processBATTERY AWARE TASK SCHEDULING FOR A SYSTEM-ON-A-CHIP USING VOLTAGE/CLOCK SCALING Princey Chowdhury Engineering Tempe AZ 85287 ABSTRACT Battery lifetime is a critical parameter in the operation of mobile

Kambhampati, Subbarao

Note: This page contains sample records for the topic "dpf voltage thd" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Low voltage blue-phase liquid crystal displays Linghui Rao,1  

E-Print Network [OSTI]

Low voltage blue-phase liquid crystal displays Linghui Rao,1 Zhibing Ge,1 Shin-Tson Wu,1,a of the emerging blue-phase liquid crystal displays BP-LCDs . Simulation results indicate that the generated-effect-induced isotropic-to-anisotropic transition in blue-phase liquid crystal BPLC 1­6 has potential to become next

Wu, Shin-Tson

482

Method for reducing fuel cell output voltage to permit low power operation  

DOE Patents [OSTI]

Fuel cell performance is degraded by recycling a portion of the cathode exhaust through the cells and, if necessary, also reducing the total air flow to the cells for the purpose of permitting operation below a power level which would otherwise result in excessive voltage.

Reiser, Carl A. (Glastonbury, CT); Landau, Michael B. (West Hartford, CT)

1980-01-01T23:59:59.000Z

483

Impact of Cyber Attacks on Transient Stability of Smart Grids with Voltage Support Devices  

E-Print Network [OSTI]

Impact of Cyber Attacks on Transient Stability of Smart Grids with Voltage Support Devices Bo Chen--Cyber security is becoming a major concern of smart grids, as the functionality of a smart grid is highly on smart grids. This paper discusses several types of cyber attacks. Then, it presents results of studies

Kundur, Deepa

484

Voltage Stability Analysis With Optimum Size and Location Based Synchronous Machine DG  

E-Print Network [OSTI]

scenar- ios for the worldwide energy supply in the future. In Australia CO2 emission from energy is much for loss reduction of the system. This paper also investigates the steady-state and dynamic voltage profile profile of the distribution system. Index Terms--Power loss reduction, distributed generation, optimum

Pota, Himanshu Roy

485

Voltage sensing systems and methods for passive compensation of temperature related intrinsic phase shift  

DOE Patents [OSTI]

A small sized electro-optic voltage sensor capable of accurate measurement of high levels of voltages without contact with a conductor or voltage source is provided. When placed in the presence of an electric field, the sensor receives an input beam of electromagnetic radiation into the sensor. A polarization beam displacer serves as a filter to separate the input beam into two beams with orthogonal linear polarizations. The beam displacer is oriented in such a way as to rotate the linearly polarized beams such that they enter a Pockels crystal at a preferred angle of 45 degrees. The beam displacer is therefore capable of causing a linearly polarized beam to impinge a crystal at a desired angle independent of temperature. The Pockels electro-optic effect induces a differential phase shift on the major and minor axes of the input beam as it travels through the Pockels crystal, which causes the input beam to be elliptically polarized. A reflecting prism redirects the beam back through the crystal and the beam displacer. On the return path, the polarization beam displacer separates the elliptically polarized beam into two output beams of orthogonal linear polarization representing the major and minor axes. In crystals that introduce a phase differential attributable to temperature, a compensating crystal is provided to cancel the effect of temperature on the phase differential of the input beam. The system may include a detector for converting the output beams into electrical signals, and a signal processor for determining the voltage based on an analysis of the output beams. The output beams are amplitude modulated by the frequency of the electric field and the amplitude of the output beams is proportional to the magnitude of the electric field, which is related to the voltage being measured.

Davidson, James R. (Idaho Falls, ID); Lassahn, Gordon D. (Idaho Falls, ID)

2001-01-01T23:59:59.000Z

486

IEEE TRANSACTIONS ON SMART GRID, VOL. 5, NO. 4, JULY 2014 1621 Realizing Unified Microgrid Voltage Profile and  

E-Print Network [OSTI]

IEEE TRANSACTIONS ON SMART GRID, VOL. 5, NO. 4, JULY 2014 1621 Realizing Unified Microgrid Voltage the information received locally from the neighboring nodes in the microgrid, and the critical nodes without DG the microgrid to have a unified voltage profile, and incorporating the subgradient method facilitates its

Qu, Zhihua

487

Voltage-and calcium-dependent gating of TMEM16A/Ano1 chloride channels are physically  

E-Print Network [OSTI]

Voltage- and calcium-dependent gating of TMEM16A/Ano1 chloride channels are physically coupled by the first intracellular loop Qinghuan Xiaoa , Kuai Yua , Patricia Perez-Cornejob , Yuanyuan Cuia , Jorge in the first intracellular loop that is crucial for both Ca2+ and voltage sensing. Deleting 448EAVK

488

Dominant-Negative Synthesis Suppression of Voltage-Gated Calcium Channel Cav2.2 Induced by Truncated Constructs  

E-Print Network [OSTI]

Dominant-Negative Synthesis Suppression of Voltage-Gated Calcium Channel Cav2.2 Induced, United Kingdom Voltage-gated calcium channel 1 subunits consist of four domains (I­IV), each with six by the cytoplasmic I-II loop of Cav2.2. It requires transmembrane seg- ments, because the isolated Cav2.2 N terminus

Dolphin, Annette C.

489

LM231A/LM231/LM331A/LM331 Precision Voltage-to-Frequency Converters  

E-Print Network [OSTI]

LM231A/LM231/LM331A/LM331 Precision Voltage-to-Frequency Converters General Description The LM231/LM331 family of voltage-to-frequency converters are ideally suited for use in simple low, the LM231A/LM331A attain a new high level of accuracy versus temperature which could only be at- tained

Lanterman, Aaron

490

Parasitic Aware Process Variation Tolerant Voltage Controlled Oscillator (VCO) Design Dhruva Ghai Saraju P. Mohanty Elias Kougianos  

E-Print Network [OSTI]

Parasitic Aware Process Variation Tolerant Voltage Controlled Oscillator (VCO) Design Dhruva Ghai that may be ap- plied to nanoscale circuits to ensure better yield. A current- starved voltage controlled oscillator (VCO) is treated as a case study and to the best of the authors' knowledge, this is the first VCO

Mohanty, Saraju P.

491

Strain-optic voltage monitor wherein strain causes a change in the optical absorption of a crystalline material  

DOE Patents [OSTI]

A voltage monitor which uses the shift in absorption edge of crystalline material to measure strain resulting from electric field-induced deformation of piezoelectric or electrostrictive material, providing a simple and accurate means for measuring voltage applied either by direct contact with the crystalline material or by subjecting the material to an electric field. 6 figs.

Weiss, J.D.

1997-01-14T23:59:59.000Z

492

Prebreakdown in low voltage varistors and its relation with deep levels P. Gaucher, R. L. Perrier and J. P. Ganne  

E-Print Network [OSTI]

. Low voltage varistors are zinc oxide based ceramic devices performing protection against electrical and is related to the presence of deep levels in the forbidden gap of the zinc oxide. These levels are studied823 Prebreakdown in low voltage varistors and its relation with deep levels P. Gaucher, R. L

Paris-Sud XI, Université de

493

Using Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage  

E-Print Network [OSTI]

Using Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage Excitation J DIELECTRIC LOSSES TO DE-ICE POWER TRANSMISSION LINES . . . 1 Using Dielectric Losses to De-Ice Power Transmission Lines with 100 kHz High-Voltage Excitation Joshua D. McCurdy, Charles R. Sullivan and Victor F

494

Marine High Voltage Power Conditioning and Transmission System with Integrated Storage DE-EE0003640 Final Report  

SciTech Connect (OSTI)

Design, Development, and test of the three-port power converter for marine hydrokinetic power transmission. Converter provides ports for AC/DC conversion of hydrokinetic power, battery storage, and a low voltage to high voltage DC port for HVDC transmission to shore. The report covers the design, development, implementation, and testing of a prototype built by PPS.

Frank Hoffmann, PhD; Aspinall, Rik

2012-12-10T23:59:59.000Z

495

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 53, NO. 2, APRIL 2006 477 Voltage-Source Active Power Filter Based on  

E-Print Network [OSTI]

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 53, NO. 2, APRIL 2006 477 Voltage-Source Active MODERN power electronics have contributed a great deal to the development of new powerful applications in line currents, which ends up distorting the voltage waveforms. Some power electronics applications

Catholic University of Chile (Universidad CatĂłlica de Chile)

496

A Thermally-Aware Methodology for Design-Specific Optimization of Supply and Threshold Voltages in Nanometer Scale ICs  

E-Print Network [OSTI]

411 A Thermally-Aware Methodology for Design-Specific Optimization of Supply and Threshold Voltages and associated thermal effects have strong impact on the packaging, cooling costs, and reliability for deep submicron technologies [2-5]. For power-constrained applications, lowering supply voltage (Vdd) offers

497

Abrupt Decline in the Open-Circuit Voltage of Direct Methanol Fuel Cells at Critical Oxygen Feed Rate  

E-Print Network [OSTI]

Abrupt Decline in the Open-Circuit Voltage of Direct Methanol Fuel Cells at Critical Oxygen Feed and Technology, Clear Water Bay, Kowloon, Hong Kong, China The open-circuit voltage OCV of a direct methanol fuel cell DMFC was measured by varying the cathode oxygen flow rate OFR while keeping the methanol

Zhao, Tianshou

498

Boosting the voltage of a salinity-gradient-power electrochemical cell by means of complex-forming solutions  

E-Print Network [OSTI]

the diaphragm constitutes a waste of free energy, which impairs the voltage generation of the concentration cell-based light-emitting electrochemical cells J. Appl. Phys. 116, 104504 (2014); 10.1063/1.4895060 Decoupled luminance decay and voltage drift in polymer light-emitting electrochemical cells: Forward bias vs. reverse

Carati, Andrea

499

Strain-optic voltage monitor wherein strain causes a change in the optical absorption of a crystalline material  

DOE Patents [OSTI]

A voltage monitor which uses the shift in absorption edge of crystalline material to measure strain resulting from electric field-induced deformation of piezoelectric or electrostrictive material, providing a simple and accurate means for measuring voltage applied either by direct contact with the crystalline material or by subjecting the material to an electric field.

Weiss, Jonathan D. (Albuquerque, NM)

1997-01-01T23:59:59.000Z

500

Investigation of channel width-dependent threshold voltage variation in a-InGaZnO thin-film transistors  

SciTech Connect (OSTI)

This Letter investigates abnormal channel width-dependent threshold voltage variation in amorphous indium-gallium-zinc-oxide (a-IGZO) thin-film transistors. Unlike drain-induced source barrier lowering effect, threshold voltage increases with increasing drain voltage. Furthermore, the wider the channel, the larger the threshold voltage observed. Because of the surrounding oxide and other thermal insulating material and the low thermal conductivity of the IGZO layer, the self-heating effect will be pronounced in wider channel devices and those with a larger operating drain bias. To further clarify the physical mechanism, fast IV measurement is utilized to demonstrate the self-heating induced anomalous channel width-dependent threshold voltage variation.

Liu, Kuan-Hsien; Chou, Wu-Ching [Department of Electrophysics, National Chiao Tung University, Hsinchu, Taiwan (China); Chang, Ting-Chang, E-mail: tcchang@mail.phys.nsysu.edu.tw [Department of Physics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Advanced Optoelectronics Technology Center, National Cheng Kung University, Taiwan (China); Wu, Ming-Siou; Hung, Yi-Syuan; Sze, Simon M. [Department of Electronics Engineering, National Chiao Tung University, Hsinchu, Taiwan (China); Hung, Pei-Hua; Chu, Ann-Kuo [Department of Photonics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Hsieh, Tien-Yu [Department of Physics, National Sun Yat-Sen University, Kaohsiung 804, Taiwan (China); Yeh, Bo-Liang [Advanced Display Technology Research Center, AU Optronics, No. 1, Li-Hsin Rd. 2, Hsinchu Science Park, Hsinchu 30078, Taiwan (China)

2014-03-31T23:59:59.000Z