1

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...  

Energy Savers [EERE]

Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models...

2

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner...  

Broader source: Energy.gov (indexed) [DOE]

Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards DOE Orders AeroSys to Halt Distribution of...

3

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Broader source: Energy.gov (indexed) [DOE]

Orders AeroSys to Halt Distribution of Inefficient Air Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models March 30, 2010 - 10:05am Addthis Today, the Department of Energy announced that it is requiring AeroSys, Inc. to stop distributing two product models - one air conditioner and one heat pump - that DOE testing found to consume more energy than allowed under federal efficiency standards. This is the latest step in the Department's investigation into whether AeroSys has been selling products in the U.S. that violate minimum appliance efficiency standards. This is the first time that the Department of Energy has told a company or manufacturer that it must halt the distribution of products that fail to

4

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Orders AeroSys to Halt Distribution of Inefficient Air Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models March 30, 2010 - 10:05am Addthis Today, the Department of Energy announced that it is requiring AeroSys, Inc. to stop distributing two product models - one air conditioner and one heat pump - that DOE testing found to consume more energy than allowed under federal efficiency standards. This is the latest step in the Department's investigation into whether AeroSys has been selling products in the U.S. that violate minimum appliance efficiency standards. This is the first time that the Department of Energy has told a company or manufacturer that it must halt the distribution of products that fail to

5

DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and  

Broader source: Energy.gov (indexed) [DOE]

Orders AeroSys to Halt Distribution of Inefficient Air Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards March 30, 2010 - 12:00am Addthis WASHINGTON, DC - Today, the Department of Energy announced that it is requiring AeroSys, Inc. to stop distributing two product models - one air conditioner and one heat pump - that DOE testing found to consume more energy than allowed under federal efficiency standards. This is the latest step in the Department's investigation into whether AeroSys has been selling products in the U.S. that violate minimum appliance efficiency standards. This is the first time that the Department of Energy has told a

6

AeroSys: Order (2011-SCE-1624) | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Order (2011-SCE-1624) Order (2011-SCE-1624) AeroSys: Order (2011-SCE-1624) December 20, 2013 DOE ordered AeroSys, Inc. (AeroSys) to pay a $100,000 civil penalty after finding AeroSys had (1) failed to certify that certain models of space-constrained central air conditioners and air conditioning heat pumps comply with the applicable energy conservation standards; and (2) manufactured and distributed in commerce in the U.S. units of noncompliant models of space-constrained central air conditioners and air conditioning heat pumps. The Order adopted a Compromise Agreement, which reflects settlement terms between DOE and AeroSys. AeroSys: Order (2011-SCE-1624) More Documents & Publications AeroSys: Proposed Penalty (2011-SCE-1624) AeroSys: Order (2010-CE-01/0201 and 2010-SE-0302)

7

AeroSys: Order (2010-CE-01/0201 and 2010-SE-0302) | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AeroSys: Order (2010-CE-01/0201 and 2010-SE-0302) AeroSys: Order (2010-CE-01/0201 and 2010-SE-0302) AeroSys: Order (2010-CE-01/0201 and 2010-SE-0302) July 1, 2010 DOE ordered AeroSys, Inc. to pay a $25,000 civil penalty after finding AeroSys had manufactured and distributed in commerce in the U.S. various models of air conditioners and air conditioning heat pumps that did not comport with the applicable energy conservation standards. In addition, AeroSys had distributed air conditioners and air conditioning heat pumps without submitting the required certification reports. The Order adopted a Compromise Agreement, which reflected settlement terms between DOE and AeroSys. AeroSys: Order (2010-CE-01/0201 and 2010-SE-0302) More Documents & Publications AeroSys: Noncompliance Determination (2010-CE-01/0201 and 2010-SE-0302)

8

AeroSys, Inc.  

Broader source: Energy.gov (indexed) [DOE]

AeroSys, Inc. AeroSys, Inc. (Central Air Conditioners) BEFORE THE U.S. DEPARTMENT OF ENERGY Washington, D.C. 20585 ) ) ) ) ) ) Case Numbers: 2010-CE-01/0201 201 0-SE-0302 NOTICE OF NONCOMPLIANCE DETERMINATION TEST DATA Pursuant to the July 1, 2010 Compromise Agreement and Adopting Order ("Agreement") between DOE and AeroSys, Inc. (AeroSys), two units of each of four models of split system, through-the-wall central air conditioning systems using R-22 refrigerant and manufactured by AeroSys were tested by Intertek in Cortland, New York, to determine compliance with applicable energy efficiency requirements. Under Section IV of the Agreement, if the results of the Intertek testing show a tested model does not meet energy efficiency requirements under

9

AeroSys: Proposed Penalty (2010-CE-01/0201) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

AeroSys: Proposed Penalty (2010-CE-01/0201) AeroSys: Proposed Penalty (2010-CE-01/0201) AeroSys: Proposed Penalty (2010-CE-01/0201) March 2, 2010 DOE alleged in a Notice of Proposed Civil Penalty that AeroSys, Inc. failed to certify residential central air conditioners and air conditioning heat pumps as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. AeroSys: Proposed Penalty (2010-CE-01/0201) More Documents & Publications AeroSys: Order (2010-CE-01/0201 and 2010-SE-0302)

10

AeroSys: Test Notice (2009) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Test Notice (2009) Test Notice (2009) AeroSys: Test Notice (2009) September 24, 2009 After examining AeroSys data, DOE concluded that the AeroSys data were insufficient to confirm whether Aerosys products comply with the applicable energy performance standards. DOE issued this test notice to AeroSys, Inc., requiring the company to provide sample units for laboratory testing to determine the compliance of various models of central air conditioners and air conditioning heat pumps with the applicable energy conservation standards. A cover letter describes the agency's actions to determine compliance prior to issuing the test notice. AeroSys: Test Notice More Documents & Publications AeroSys: Noncompliance Determination (2010-SE-0302) AeroSys: Noncompliance Determination (2010-SE-0302)

11

Department of Energy Subpoenas Compliance Data from AeroSys,...  

Energy Savers [EERE]

Inc. yesterday to obtain data necessary to determine whether certain AeroSys commercial air conditioners and heat pumps comply with relevant DOE energy efficiency standards. The...

12

AeroSys: Noncompliance Determination (2010-CE-01/0201 and 2010-SE-0302) |  

Broader source: Energy.gov (indexed) [DOE]

AeroSys: Noncompliance Determination (2010-CE-01/0201 and AeroSys: Noncompliance Determination (2010-CE-01/0201 and 2010-SE-0302) AeroSys: Noncompliance Determination (2010-CE-01/0201 and 2010-SE-0302) September 27, 2011 DOE issued a Notice of Noncompliance Determination to AeroSys, Inc. finding that basic models THDC-18S, THDC-18T, THDC-24S, and THDC-24T do not comport with the energy conservation standards. DOE determined the products were noncompliant based on DOE testing. AeroSys must immediately notify each person (or company) to whom AeroSys distributed the noncompliant products that the products do not meet Federal standards. In addition, AeroSys must provide to DOE documents and records showing the number of units AeroSys distributed and to whom. The manufacturer and/or private labeler of the product may be subject to civil penalties.

13

DOE Institutes Enforcement Action Against AeroSys, Inc. for Failure to Certify Air Conditioners and Heat Pumps  

Broader source: Energy.gov [DOE]

Washington, DC - The Department of Energys Office of General Counsel has issued a Notice of Proposed Civil Penalty to AeroSys, Inc. for failing to file certification reports or filing data that...

14

AeroSys: Noncompliance Determination (2010-SE-0302) | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Noncompliance Determination (2010-SE-0302) Noncompliance Determination (2010-SE-0302) AeroSys: Noncompliance Determination (2010-SE-0302) April 13, 2010 DOE issued a Notice of Noncompliance Determination to AeroSys, Inc. finding that basic model THDC-24SG does not comport with the energy conservation standards. DOE determined the product was noncompliant based on DOE testing. AeroSys must immediately notify each person (or company) to whom AeroSys distributed the noncompliant product that the product does not meet Federal standards. In addition, AeroSys must provide to DOE documents and records showing the number of units AeroSys distributed and to whom. The manufacturer and/or private labeler of the product may be subject to civil penalties. AeroSys: Noncompliance Determination (2010-SE-0302)

15

DOE Institutes Enforcement Action Against AeroSys, Inc. for Failure...  

Energy Savers [EERE]

provide DOE with information critical to determining that American consumers are buying products that deliver significant energy and cost savings in accord with DOE's...

16

Aerosys Agrees to Pay Civil Penalty and Submit Test Data in Settlement with  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Aerosys Agrees to Pay Civil Penalty and Submit Test Data in Aerosys Agrees to Pay Civil Penalty and Submit Test Data in Settlement with DOE Aerosys Agrees to Pay Civil Penalty and Submit Test Data in Settlement with DOE July 6, 2010 - 3:08pm Addthis WASHINGTON, DC - The Department of Energy announced today that AeroSys, Inc. has agreed to pay a civil penalty of $25,000 and take a number of other actions designed to ensure its future compliance with DOE's energy efficiency standards. Last fall, the Department subpoenaed AeroSys's data on the energy use of certain heat pumps and air conditioners and then issued a demand to test 6 air conditioner models and one heat pump. DOE testing revealed that one heat pump model and two air conditioner models consumed more energy than allowed under federal efficiency standards and required AeroSys to cease distribution of those models. DOE also issued

17

AeroSys: Noncompliance Determination (2010-SE-0302)  

Broader source: Energy.gov [DOE]

DOE issued a Notice of Noncompliance Determination to AeroSys, Inc. finding that basic models THHP-24T* and THDC-30T* do not comport with the energy conservation standards.

18

Department of Energy Announces Testing for AeroSys, Inc. Products to Ensure  

Broader source: Energy.gov (indexed) [DOE]

Testing for AeroSys, Inc. Products Testing for AeroSys, Inc. Products to Ensure Compliance with Appliance Standards Department of Energy Announces Testing for AeroSys, Inc. Products to Ensure Compliance with Appliance Standards September 24, 2009 - 12:00am Addthis Washington, DC - As part of its renewed efforts to ensure compliance with national energy efficiency appliance standards, the U.S. Department of Energy today issued a test notice requiring AeroSys, Inc. to provide sample air conditioners and heat pumps for laboratory testing by DOE. The test notice, issued under 10 CFR 430.70, requires AeroSys to make test samples of certain AeroSys-manufactured air conditioners and heat pumps available to DOE at its own expense. The Department will then determine whether these products comply with applicable DOE energy standards, which are

19

DOE Issues Notice of Proposed Rulemaking to Improve Energy Efficiency...  

Energy Savers [EERE]

DOE Institutes Enforcement Action Against AeroSys, Inc. for Failure to Certify Air Conditioners and Heat Pumps Department of Energy Announces Testing for AeroSys, Inc....

20

BY FAX AND CERTIFIED MAIL James A. Garrett President AeroSys, Inc.  

Broader source: Energy.gov (indexed) [DOE]

13, 2010 13, 2010 BY FAX AND CERTIFIED MAIL James A. Garrett President AeroSys, Inc. 929 Eldridge Drive Hagerstown, MD 21740 Dear Mr. Garrett: The attached notice advises you of test results stemming from the September 24, 2009 test notice issued by the United States Department of Energy (DOE) pursuant to 10 CFR § 430.70 regarding the performance of the remaining products manufactured by AeroSys, Inc. (AeroSys) that were selected for enforcement testing. The notice also advises you of your legal obligations. Violations of the applicable energy-efficiency standards may be subject to civil penalties. Separate from this notice, DOE may issue a notice of liability for such penalties as appropriate. As specified in the attached notice, DOE asks that AeroSys acknowledge receipt of this notice

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

AeroSys: Proposed Penalty (2011-SCE-1624) | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Proposed Penalty (2011-SCE-1624) Proposed Penalty (2011-SCE-1624) AeroSys: Proposed Penalty (2011-SCE-1624) September 30, 2013 DOE alleged in an Amended Notice of Proposed Civil Penalty (NPCP) that AeroSys, Inc. failed to certify various basic models of space-constrained central air conditioners and air conditioning heat pumps as compliant with the applicable energy conservation standards. DOE also alleged in the NPCP that AeroSys, Inc. manufactured and distributed in the U.S. noncompliant space-constrained central air conditioners and air conditioning heat pumps. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. Federal law subjects manufacturers and private labelers to civil penalties

22

AeroSys, Inc. Respondent BEFORE THE U.S. DEPARTMENT OF ENERGY  

Broader source: Energy.gov (indexed) [DOE]

Respondent Respondent BEFORE THE U.S. DEPARTMENT OF ENERGY WASHINGTON, D.C. 20585 ) ) ) ) ) ) ORDER Case Number: 20 l 1-SCE-1624 By authority of the Secretary, U.S. Department of Energy: I . In this Order, I adopt the attached Compromise Agreement entered into between the U.S. Department of Energy ("DOE») and AeroSys, Inc. {"Respondent"). The Compromise Agreement resolves the case initiated to pmsue a civil penalty for violations of DOE regulatory requirements at 10 C.F.R. §§ 429.12, 429.16, and 430.32(c). 2. The DOE and Respondent have negotiated the terms of the Compromise Agreement that resolves this matter. A copy of the Compromise Agreement is attached hereto and incorporated by reference. 3. After reviewing the terms of the Compromise Agreement and evaluating the facts

23

DOE Steps Lead to Significant Increase in Compliance with Energy...  

Office of Environmental Management (EM)

Department of Energy Subpoenas Compliance Data from AeroSys, Inc. DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards...

24

DOE Order on Quality Assurance  

Broader source: Energy.gov [DOE]

The purpose of this order is to ensure that Department of Energy (DOE), including National Nuclear Security Administration (NNSA), products and services meet or exceed customers requirements and...

25

DOE Order on Quality Assurance  

Broader source: Energy.gov (indexed) [DOE]

INITIATED BY: INITIATED BY: www.directives.doe.gov Office of Health, Safety and Security U.S. Department of Energy ORDER Washington, D.C. Approved: 4-25-2011 SUBJECT: QUALITY ASSURANCE 1. PURPOSE. a. To ensure that Department of Energy (DOE), including National Nuclear Security Administration (NNSA), products and services meet or exceed customers' requirements and expectations. b. To achieve quality for all work based upon the following principles: (1) All work, as defined in this Order, is conducted through an integrated and effective management system; (2) Management support for planning, organization, resources, direction, and control is essential to quality assurance (QA); (3) Performance and quality improvement require thorough, rigorous

26

Department of Energy Announces Testing for AeroSys, Inc. Products...  

Office of Environmental Management (EM)

energy efficiency appliance standards, the U.S. Department of Energy today issued a test notice requiring AeroSys, Inc. to provide sample air conditioners and heat pumps for...

27

DOE Order 482.1 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Order 482.1 DOE Order 482.1 DOE FACILITIES TECHNOLOGY PARTNERING PROGRAMS DOE Order 482.1 More Documents & Publications DOE Cooperative Research and Development Agreements DOE M...

28

Proposed Strategy to meet DOE Order 231  

Broader source: Energy.gov (indexed) [DOE]

Page 1 Page 1 Proposed Strategy to meet DOE Order 231.1B, Preparation of Annual Site Environmental Reports Background The U.S. Department of Energy Office (DOE) of Legacy Management (LM) was established in 2003 to manage the Department's post-closure responsibilities at sites under LM's care and ensure the future protection of human health and the environment at those sites. The histories of the legacy sites vary, as does the regulatory regime under which the sites are managed. Long- term surveillance plans (LTSPs) are prepared for the majority of the sites. These LTSPs, which are available to the public, include site descriptions, information about site history, nature and extent of contamination, institutional controls, closeout condition of the site, present and future

29

Order Module--DOE Order 422.1, CONDUCT OF OPERATIONS | Department...  

Energy Savers [EERE]

Order Module--DOE Order 422.1, CONDUCT OF OPERATIONS Order Module--DOE Order 422.1, CONDUCT OF OPERATIONS The general approach to implementing DOE O 422.1 is for contractors to...

30

DOE Order Self Study Modules - Getting Started  

Broader source: Energy.gov (indexed) [DOE]

Getting Started DOE Orders Self-Study Program Getting Started August 2011 1 U.S. DEPARTMENT OF ENERGY ORDERS SELF-STUDY PROGRAM GETTING STARTED This course was developed using the Criterion Referenced Instruction (CRI) method of training. That means the course contains only the information you need to perform your job. You will be shown the learning objectives at the beginning of the course. If you think you can demonstrate competency without additional instruction, you may complete the practice at any time. When you complete all of the practices successfully, you may ask the course manager for the criterion test. The familiar level requires that you understand and remember the material. The general level requires that you understand the applicability of the material. If you are unsure of the level of proficiency

31

DOE Order 435.1 - Performance Assessments and Waste Incidental...  

Office of Environmental Management (EM)

Performance Assessment DOE Order 435.1 Performance Assessments Savannah River Site West Valley Demonstration Project DOE Manual 435.1-1 Waste Incidental to Reprocessing...

32

Revision to DOE Order 435.1 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Program Management » Compliance » Revision to DOE Program Management » Compliance » Revision to DOE Order 435.1 Revision to DOE Order 435.1 The Office of Environmental Management has primary responsibility, within DOE, for DOE Order 435.1, the self-regulation of radioactive waste management. As part of this responsibility, EM has decided to update the Order to incorporate several changes to the regulatory process that have taken place over the last decade as well as streamline the Order to improve management of the waste. A comprehensive complex-wide review of DOE radioactive waste management activities associated with implementation of the requirements of DOE Order 435.1, Radioactive Waste Management, was conducted in 2010 in order to gather feedback on the effectiveness of the DOE Order 435.1 requirements (not to assess compliance with the

33

DOE Order Self Study Modules - DOE STD 1063, Facility Representatives  

Broader source: Energy.gov (indexed) [DOE]

63-2011 63-2011 FACILITY REPRESENTATIVES DOE-STD-1063-2011 Familiar Level August 2011 1 DOE-STD-1063-2011 FACILITY REPRESENTATIVES FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to answer the following questions: 1. What are the purpose and scope of DOE-STD-1063-2011? 2. What are the definitions of the terms listed in section 3 of DOE-STD-1063-2011? 3. What are the duties, responsibilities, and authorities of facility representatives (FRs) and other key personnel? 4. What are the requirements of the FR program? 5. What are the Department of Energy (DOE)-wide FR performance indicators (PIs)? 6. How are DOE-wide FR PIs calculated? 7. What are the FR program objectives that should be measured by an FR program

34

DOE Orders/Standards and Applicable CFRs/DEAR Crosswalk  

Broader source: Energy.gov (indexed) [DOE]

DOE Orders/Standards and Applicable CFRs/DEAR Crosswalk DOE Order Title Date Corresponding Standards Corresponding CFRs/DEAR Clauses DOE O 3790.1B Federal Employee Occupational Safety and Health Program 1/93 ½ DOE-STD-1138-2000 ½ DOE-STD-1120-98 ½ DOE O 4700.1 Project Management System 3/87 Chg 1 6/92 ½ DOE-STD-1073-93 ½ DOE-STD-1128-98 ½ DOE-STD-6003-96 ½ DOE-HDBK-3027-99 ½ 10 CFR 835 DOE O 5400.1 General Environmental Protection Program 11/88 Chg 1 6/90 ½ DOE-STD-1120-98 ½ DOE-STD-1136-2000 ½ DOE-STD-1146-2001 ½ DOE-STD-6003-96 ½ DOE O 5480.4 Environmental Protection, Safety, and Health, Protection Standards 5/84 Chg 4 1/93 ½ DOE-STD-1027-92 ½ DOE-STD-1128-98 ½ DOE-HDBK-1101-96 ½ DOE-STD-1098-99 ½ DOE-STD-1138-2000 ½ DOE-HDBK-6004-99 ½ DOE-HDBK-3012-96 ½ 10 CFR 835

35

LFRG DOE Order 435.1 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

LFRG DOE Order 435.1 LFRG DOE Order 435.1 LFRG DOE Order 435.1 Chapter 4 of the DOE Manual on Order 435.1, Low-level Waste Requirements, addresses the procedures whereby Department of Energy LLW Disposal Facilities will operated and maintained. Section P and Section Q describe the Performance Assessment and Composite Analysis documents that each DOE disposal facility will submit to the LFRG. To view the entire DOE Order, Manual, and Implementation Guidance documents, choose the link below to get to the main DOE Directives portal and follow the search requirements. DOE Directives, Regulations, and Standards Portal Note - For DOE O 435.1 Chg 1 (08-28-01), please use the above link and follow the search option to locate this document. P. Disposal. Low-level waste disposal facilities shall meet the following

36

Order Module--DOE O 433.1B, MAINTENANCE MANAGEMENT PROGRAM FOR DOE NUCLEAR FACILITIES  

Broader source: Energy.gov [DOE]

"The familiar level of this module is designed to summarize the basic information in DOE O 433.1B, Maintenance Management Program for DOE Nuclear Facilities. This Order canceled DOE O 433.1A. This...

37

Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING  

Broader source: Energy.gov (indexed) [DOE]

Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING NNSA) FEDERAL EMPLOYEES Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING NNSA) FEDERAL EMPLOYEES The familiar level of this module is divided into two sections. In the first section, we will discuss the objective, requirements, and the responsibilities assigned to the heads of field elements. In the second section, we will discuss the content of attachment 1, Functional Area Requirements. We have provided examples and a practice to help familiarize you with the material. The practice will also help prepare you for the criterion test. DOE Order Self Study Modules - DOE O 440.1B, Worker Protection Management for DOE (Including the National Nuclear Security Administration) Federal

38

Order Module--DOE O 433.1B, MAINTENANCE MANAGEMENT PROGRAM FOR DOE NUCLEAR  

Broader source: Energy.gov (indexed) [DOE]

33.1B, MAINTENANCE MANAGEMENT PROGRAM FOR DOE 33.1B, MAINTENANCE MANAGEMENT PROGRAM FOR DOE NUCLEAR FACILITIES Order Module--DOE O 433.1B, MAINTENANCE MANAGEMENT PROGRAM FOR DOE NUCLEAR FACILITIES "The familiar level of this module is designed to summarize the basic information in DOE O 433.1B, Maintenance Management Program for DOE Nuclear Facilities. This Order canceled DOE O 433.1A. This module is divided into three sections. Section one contains the objective, general requirements, and the responsibilities assigned to field element managers. Section two includes the requirements in attachment 2 of the Order, Maintenance Management Program Requirements for DOE Nuclear Facilities. Section three is a summary of the guidance provided in DOE G 433.1-1, Facility Maintenance Management Program Guide for Use with DOE O 433.1.The

39

DOE Orders Mirant Power Plant to Operate Under Limited Circumstances |  

Broader source: Energy.gov (indexed) [DOE]

DOE Orders Mirant Power Plant to Operate Under Limited DOE Orders Mirant Power Plant to Operate Under Limited Circumstances DOE Orders Mirant Power Plant to Operate Under Limited Circumstances December 20, 2005 - 11:44am Addthis DOE finds emergency; determines plant will help electric reliability WASHINGTON, D.C. - Secretary of Energy Samuel W. Bodman today issued an order requiring Mirant Corporation's Potomac River Generating Station in Alexandria, Virginia (Mirant) to immediately resume limited operation. The order will help provide electric reliability for Washington, D.C., and will do so at the lowest reasonable impact to the environment. "After weighing all of the information, I believe an emergency situation exists, and that issuance of this order is in the public interest. This order will provide the level of electricity reliability necessary to keep

40

DOE Order 440. 1 B: Worker Protection Program for DOE (Including NNSA)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

0. 1 B: Worker Protection Program for DOE (Including 0. 1 B: Worker Protection Program for DOE (Including NNSA) Federal Employees DOE Order 440. 1 B: Worker Protection Program for DOE (Including NNSA) Federal Employees Stakeholders: DOE and NNSA employees Scope: DOE Order 440.1 B establishes the framework for an effective worker protection program that will reduce or prevent injuries, illnesses, and accidental losses by providing Department of Energy, including National Nuclear Security Administration (NNSA), Federal workers with a safe and healthful workplace. Summary: Among the requirements of DOE Order 440.1 B, the Department must provide its employees, including NNSA, a number of protections relating to whistle blowing guidelines. The relevant section of requirements includes: 4. REQUIREMENTS. DOE elements must:

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Impact of DOE Orders on Waste Management Operation  

SciTech Connect (OSTI)

Department of Energy Orders are the internal documents which govern the management of all Department of Energy facilities and operations. DOE Orders are the vehicles by which Federal and state laws and regulations are applied to Department of Energy activities. A selected set of 22 Department of Energy Orders was reviewed to identify the applicability and impact of each Order on waste management operations at Los Alamos National Laboratory. Of the 22 Orders reviewed, five set forth requirements which have a high degree of impact on waste management activities. Eight Orders have a moderate degree of impact on waste management activities, and the remaining nine Orders have a low degree of impact.

Klein, R.B.; Jennrich, E.A.; Shuman, R.; Sandquist, G.M. (Rogers and Associates Engineering Corp., Salt Lake City, UT (United States)); Rutz, A.C.; Littleton, M.W.; McCauce, C.H. (Wastren, Inc., Idaho Falls, ID (United States))

1989-09-01T23:59:59.000Z

42

DOE Orders Mirant Power Plant to Operate Under Limited Circumstances |  

Broader source: Energy.gov (indexed) [DOE]

Orders Mirant Power Plant to Operate Under Limited Orders Mirant Power Plant to Operate Under Limited Circumstances DOE Orders Mirant Power Plant to Operate Under Limited Circumstances Docket No. EO-05-01. Order No. 202-05-3: Secretary of Energy Samuel W. Bodman today issued an order requiring Mirant Corporation's Potomac River Generating Station in Alexandria, Virginia (Mirant) to immediately resume limited operation. The order will help provide electric reliability for Washington, D.C., and will do so at the lowest reasonable impact to the environment. DOE Orders Mirant Power Plant to Operate Under Limited Circumstances More Documents & Publications Comments on Department of Energy's Emergency Order To Resume Limited Operation at Mirant's Potomac River Generating Station and Proposed Mirant Compliance Plan

43

DOE Awards Research and Systems Engineering Task Order | Department of  

Broader source: Energy.gov (indexed) [DOE]

Research and Systems Engineering Task Order Research and Systems Engineering Task Order DOE Awards Research and Systems Engineering Task Order March 28, 2013 - 12:00pm Addthis Media Contact Bill Taylor, 803-952-8564 Bill.Taylor@srs.gov Cincinnati - The U.S. Department of Energy (DOE) today awarded a task order to The MITRE Corporation, of McLean Virginia. MITRE will provide research and development in support of DOE's Office of Environmental Management. The task order has an approximate value of $5.9 million, with an 18-month performance period, with nine-month base period and a nine-month option. The MITRE Corporation is a not-for-profit organization chartered to work for the interest of the public. MITRE manages the Internal Revenue Service Federally Funded Research and Development Center (FFRDC) Master Indefinite

44

DOE Orders Mirant Power Plant to Operate Under Limited Circumstances |  

Broader source: Energy.gov (indexed) [DOE]

Orders Mirant Power Plant to Operate Under Limited Orders Mirant Power Plant to Operate Under Limited Circumstances DOE Orders Mirant Power Plant to Operate Under Limited Circumstances December 20, 2005 - 11:44am Addthis DOE finds emergency; determines plant will help electric reliability WASHINGTON, D.C. - Secretary of Energy Samuel W. Bodman today issued an order requiring Mirant Corporation's Potomac River Generating Station in Alexandria, Virginia (Mirant) to immediately resume limited operation. The order will help provide electric reliability for Washington, D.C., and will do so at the lowest reasonable impact to the environment. "After weighing all of the information, I believe an emergency situation exists, and that issuance of this order is in the public interest. This order will provide the level of electricity reliability necessary to keep

45

DOE Awards Task Order for Lexington Project Office Audit  

Broader source: Energy.gov [DOE]

Cincinnati - The U.S. Department of Energy (DOE) Office of Environmental Management today awarded a task order to KPMG LLP, of McLean, Virginia to perform audit services for the Portsmouth/Paducah Project Office in Lexington, Kentucky. The task order has an approximate value of $2.9 million over a two-year performance period.

46

Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING  

Broader source: Energy.gov (indexed) [DOE]

40.1B, WORKER PROTECTION PROGRAM FOR DOE 40.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING NNSA) FEDERAL EMPLOYEES Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING NNSA) FEDERAL EMPLOYEES The familiar level of this module is divided into two sections. In the first section, we will discuss the objective, requirements, and the responsibilities assigned to the heads of field elements. In the second section, we will discuss the content of attachment 1, Functional Area Requirements. We have provided examples and a practice to help familiarize you with the material. The practice will also help prepare you for the criterion test. DOE Order Self Study Modules - DOE O 440.1B, Worker Protection Management for DOE (Including the National Nuclear Security Administration) Federal Employees

47

Order Module--DOE STD-1098-2008, DOE STANDARD: RADIOLOGICAL CONTROL |  

Broader source: Energy.gov (indexed) [DOE]

STD-1098-2008, DOE STANDARD: RADIOLOGICAL CONTROL STD-1098-2008, DOE STANDARD: RADIOLOGICAL CONTROL Order Module--DOE STD-1098-2008, DOE STANDARD: RADIOLOGICAL CONTROL "The radiological control program discussed in DOE-STD-1098-2008 goes beyond the scope of, and includes more details than, the documented radiation protection program (RPP) required by 10 CFR 835, -Occupational Radiation Protection.‖ To ensure implementation of a comprehensive and coherent radiological control program that exceeds basic requirements and provides a substantial safety margin, DOE encourages its contractors to implement the provisions of DOE-STD-1098- 2008 to the extent appropriate to facility hazards and operations, consistent with DOE's integrated safety management program. Should any conflicts arise between the site-specific radiological control manual and the documented RPP, the

48

Order Module--DOE O 460.1C, PACKAGING AND TRANSPORTATION SAFETY, DOE O  

Broader source: Energy.gov (indexed) [DOE]

O 460.1C, PACKAGING AND TRANSPORTATION SAFETY, O 460.1C, PACKAGING AND TRANSPORTATION SAFETY, DOE O 460.2A, DEPARTMENTAL MATERIALS TRANSPORTATION AND PACKAGING MANAGEMENT Order Module--DOE O 460.1C, PACKAGING AND TRANSPORTATION SAFETY, DOE O 460.2A, DEPARTMENTAL MATERIALS TRANSPORTATION AND PACKAGING MANAGEMENT "The familiar level of this module is divided into two sections. The objectives and requirements of DOE O 460.1C and DOE O 460.2A will be discussed in the first and second sections, respectively. Several examples and practices throughout the module are provided to help familiarize you with the material. The practices will also help prepare you for the criterion test. Before continuing, you should obtain a copy of the Orders and implementation guides and manuals for this module. Copies of the Orders are available on the internet

49

Order Module--DOE Order 422.1, CONDUCT OF OPERATIONS | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

422.1, CONDUCT OF OPERATIONS 422.1, CONDUCT OF OPERATIONS Order Module--DOE Order 422.1, CONDUCT OF OPERATIONS The general approach to implementing DOE O 422.1 is for contractors to develop, for DOE line management approval, documentation demonstrating implementation of the requirements in the contractor requirements document (CRD). DOE line management means the Federal officials such as Secretarial Officers and heads of field elements responsible for DOE facilities and operations. It is necessary to provide a conduct of operations matrix, which is a list of CRD requirements, citing the specific documentation that implements each item, or providing justification for each item that is not implemented. DOE line management must determine which facilities, other than hazard category 1, 2, and 3 nuclear facilities, require implementation

50

Order Module--DOE Order 225.1B, ACCIDENT INVESTIGATIONS | Department of  

Broader source: Energy.gov (indexed) [DOE]

Order 225.1B, ACCIDENT INVESTIGATIONS Order 225.1B, ACCIDENT INVESTIGATIONS Order Module--DOE Order 225.1B, ACCIDENT INVESTIGATIONS DOE O 225.1B prescribes organizational responsibilities, authorities, and requirements for conducting investigations of certain accidents occurring at DOE sites, facilities, areas, operations, and activities. The purpose of the accident investigation is to understand and identify the causes that contributed to the accident so those deficiencies can be addressed and corrected. This, in turn, is intended to prevent recurrence and promote improved environmental protection and safety and health of DOE employees, contractors, and the public. Moreover, accident investigations are used to promote the values and concepts of a learning organization. The department's integrated safety management (ISM) feedback and improvement

51

American Indian Policy and Relevant DOE and Executive Orders | Department  

Broader source: Energy.gov (indexed) [DOE]

Tribal Programs » Tribal Programs » American Indian Policy and Relevant DOE and Executive Orders American Indian Policy and Relevant DOE and Executive Orders Over the course of American history, the Federal government's relationship with Indian Tribes has been defined and modified by treaties, executive orders, court decisions, specific legislation passed by Congress, and regulations. Important rights were guaranteed to Tribes by treaty, with many of these rights still enforceable today. Case law, over the years, has dealt with the status of Indian Tribes and their special relationship to the Federal government. Legislation, passed by Congress reflects the national Indian policy at the time of enactment. Current Federal Indian policy recognizes that Indian Tribes are an integral

52

Ordering Information | U.S. DOE Office of Science (SC)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Certified Certified Reference Materials (CRMs) » Ordering Information New Brunswick Laboratory (NBL) NBL Home About Programs Certified Reference Materials (CRMs) Prices and Certificates Ordering Information Training Categorical Exclusion Determinations News Contact Information New Brunswick Laboratory U.S. Department of Energy Building 350 9800 South Cass Avenue Argonne, IL 60439-4899 P: (630) 252-2442 (NBL) P: (630) 252-2767 (CRM sales) F: (630) 252-6256 E: usdoe.nbl@ch.doe.gov Certified Reference Materials (CRMs) Ordering Information Print Text Size: A A A RSS Feeds FeedbackShare Page Those CRMs that contain plutonium, enriched uranium, or U-233 are defined by 10 CFR 110, and are so noted in the catalog. These CRMs may be purchased domestically only under a valid DOE contractor or NRC license number.

53

Introduction to DOE Order 435.1 Low Level Radioactive Waste Disposal...  

Broader source: Energy.gov (indexed) [DOE]

Introduction to DOE Order 435.1 Low Level Radioactive Waste Disposal Requirements Introduction to DOE Order 435.1 Low Level Radioactive Waste Disposal Requirements Christine...

54

DOE Order Self Study Modules - DOE O 225.1B, Accident Investigation  

Broader source: Energy.gov (indexed) [DOE]

225.1B 225.1B ACCIDENT INVESTIGATIONS DOE O 225.1B Accident Investigations Familiar Level June 2011 1 June 2011 DOE ORDER O 225.1B ACCIDENT INVESTIGATIONS FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to: 1. State the purpose of implementing U.S. Department of Energy (DOE) O 225.1B. 2. Discuss the responsibilities of the heads of field elements for accident investigations. 3. Discuss the responsibilities of the appointing official in an accident investigation. 4. Discuss the responsibilities of the Accident Investigation Board Chairperson. 5. Discuss the criteria identified in appendix A of DOE O 225.1B. Note: If you think that you can complete the practice at the end of this level without

55

DOE Order Self Study Modules - DOE O 420.1B Facility Safety  

Broader source: Energy.gov (indexed) [DOE]

0.1B 0.1B FACILITY SAFETY NATIONAL NUCLEAR SECURITY ADMINISTRATION LEARNING AND CAREER DEVELOPMENT DEPARTMENT CHANGE NO: 2 DOE O 420.1B Level: Familiar Date: 12/1/08 1 DOE ORDER O 420.1B FACILITY SAFETY FAMILIAR LEVEL _________________________________________________________________________ OBJECTIVES Given the familiar level of this module and the listed resources, you will be able to perform the following: 1. State the purpose of implementing DOE O 420.1B. 2. State who is responsible for complying with the requirements of this Order. 3. State the general and design requirements for nuclear safety. 4. State the general programmatic requirements for an acceptable fire protection program. 5. State the fire protection design requirements for a comprehensive fire protection

56

"Order Module--DOE O 470.4B, SAFEGUARDS AND SECURITY PROGRAM, DOE O 471.6,  

Broader source: Energy.gov (indexed) [DOE]

"Order Module--DOE O 470.4B, SAFEGUARDS AND SECURITY PROGRAM, DOE O "Order Module--DOE O 470.4B, SAFEGUARDS AND SECURITY PROGRAM, DOE O 471.6, INFORMATION SECURITY, DOE O 473.3 "Order Module--DOE O 470.4B, SAFEGUARDS AND SECURITY PROGRAM, DOE O 471.6, INFORMATION SECURITY, DOE O 473.3 The familiar level of this module is divided into four sections. In the first section, we will discuss the DOE security programs and design basis threat included in DOE O 470.4B, Safeguards and Security Program. In the second section, we will discuss information security programs, including control of classified materials and the responsibilities of field elements and contractor employees in identifying classified information as covered in DOE O 471.6, Information Security. In section three, we will discuss the security programs to include security areas, intrusion detection, and

57

"Order Module--DOE O 470.4B, SAFEGUARDS AND SECURITY PROGRAM, DOE O 471.6,  

Broader source: Energy.gov (indexed) [DOE]

"Order Module--DOE O 470.4B, SAFEGUARDS AND SECURITY PROGRAM, DOE O "Order Module--DOE O 470.4B, SAFEGUARDS AND SECURITY PROGRAM, DOE O 471.6, INFORMATION SECURITY, DOE O 473.3 "Order Module--DOE O 470.4B, SAFEGUARDS AND SECURITY PROGRAM, DOE O 471.6, INFORMATION SECURITY, DOE O 473.3 The familiar level of this module is divided into four sections. In the first section, we will discuss the DOE security programs and design basis threat included in DOE O 470.4B, Safeguards and Security Program. In the second section, we will discuss information security programs, including control of classified materials and the responsibilities of field elements and contractor employees in identifying classified information as covered in DOE O 471.6, Information Security. In section three, we will discuss the security programs to include security areas, intrusion detection, and

58

Request that DOE rescind Order No. 202-05-03 and Order No. 202-06-01 |  

Broader source: Energy.gov (indexed) [DOE]

that DOE rescind Order No. 202-05-03 and Order No. that DOE rescind Order No. 202-05-03 and Order No. 202-06-01 Request that DOE rescind Order No. 202-05-03 and Order No. 202-06-01 Docket No. EO-05-01: On behalf of the City of Alexandria ("Alexandria"), and pursuant to Department of Energy ("DOE") Order No. 202-05-3 and Order No. 202-06-1, we respectfully request that the DOE immediately rescind its authorization for the operation of the Potomac River Generating Station ("PRGS") under the so-called Operating Plan "Option A". The PRGS is not operating pursuant to the operating configuration set out in "Option A" and its operation is in violation of Federal and Commonwealth of Virginia air quality standards. We also submit comments herein to reply to the Potomac

59

Policy Flash 2014-30 DOE Order 412.1a, Work Authorization System...  

Broader source: Energy.gov (indexed) [DOE]

0 DOE Order 412.1a, Work Authorization System Administrative Change Policy Flash 2014-30 DOE Order 412.1a, Work Authorization System Administrative Change Questions concerning this...

60

"Order Module--DOE O 442.1, DEPARTMENT OF ENERGY EMPLOYEE CONCERNS...  

Office of Environmental Management (EM)

"Order Module--DOE O 442.1, DEPARTMENT OF ENERGY EMPLOYEE CONCERNS PROGRAM "Order Module--DOE O 442.1, DEPARTMENT OF ENERGY EMPLOYEE CONCERNS PROGRAM The familiar level of this...

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

ORISE: The Value of Independence, a white paper on DOE Order...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Value of Independence ORISE white paper explains how DOE Order 458.1 brings independent verification to the forefront of D&D projects With the release of DOE Order 458.1 in...

62

Briefing, DOE Order 475.2B, Identifying Classified Information, What Derivative Classifiers Should Know  

Broader source: Energy.gov [DOE]

This briefing provides Derivative Classifiers with information regarding the changes to the DOE Order on Identifying Classified Information.

63

Order Module--DOE O 435.1 RADIOACTIVE WASTE MANAGEMENT | Department of  

Broader source: Energy.gov (indexed) [DOE]

35.1 RADIOACTIVE WASTE MANAGEMENT 35.1 RADIOACTIVE WASTE MANAGEMENT Order Module--DOE O 435.1 RADIOACTIVE WASTE MANAGEMENT DOE Order 5820.2A, Radioactive Waste Management, was issued by DOE in September 1988. As early as 1990, DOE began analyzing, assessing, and reviewing the process of implementing the Order. DOE revised the Order on radioactive waste management for several reasons: - After thorough technical reviews and analyses, DOE and the Defense Nuclear Facilities Safety Board concluded that DOE Order 5820.2A did not adequately address the Department's radioactive waste management and disposal practices. -There had been significant advances in radioactive waste management practices and changes in DOE since the Order was issued in 1988. - Risk-based and performance-based requirements were determined to be

64

Order Module--DOE O 435.1 RADIOACTIVE WASTE MANAGEMENT | Department of  

Broader source: Energy.gov (indexed) [DOE]

O 435.1 RADIOACTIVE WASTE MANAGEMENT O 435.1 RADIOACTIVE WASTE MANAGEMENT Order Module--DOE O 435.1 RADIOACTIVE WASTE MANAGEMENT DOE Order 5820.2A, Radioactive Waste Management, was issued by DOE in September 1988. As early as 1990, DOE began analyzing, assessing, and reviewing the process of implementing the Order. DOE revised the Order on radioactive waste management for several reasons: - After thorough technical reviews and analyses, DOE and the Defense Nuclear Facilities Safety Board concluded that DOE Order 5820.2A did not adequately address the Department's radioactive waste management and disposal practices. -There had been significant advances in radioactive waste management practices and changes in DOE since the Order was issued in 1988. - Risk-based and performance-based requirements were determined to be

65

DOE Order Self Study Modules - DOE O 452.1D, Nuclear Explosive and Weapon Surety Program and  

Broader source: Energy.gov (indexed) [DOE]

CONTINUING TRAINING SELF- CONTINUING TRAINING SELF- STUDY PROGRAM DOE O 452.1D NUCLEAR EXPLOSIVE AND WEAPON SURETY PROGRAM DOE O 452.2D NUCLEAR EXPLOSIVE SAFETY DOE O 452.1D and DOE O 452.2D Familiar Level June 2011 1 DOE O 452.1D NUCLEAR EXPLOSIVE AND WEAPON SURETY PROGRAM DOE O 452.2D NUCLEAR EXPLOSIVE SAFETY FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to answer the following questions: 1. What are the objectives of implementing U.S. Department of Energy (DOE) O 452.1D? 2. Define the following terms as they apply to this Order: Abnormal environment High explosive detonation 3. What are the objectives of implementing DOE O 452.2D? 4. What are the general requirements of DOE O 452.2D?

66

Enforcement Cases  

Broader source: Energy.gov (indexed) [DOE]

cases Office of the General Counsel 1000 cases Office of the General Counsel 1000 Independence Ave., SW Washington, DC, 20585 202-586-5281 en AeroSys: Order (2011-SCE-1624) http://energy.gov/gc/downloads/aerosys-order-2011-sce-1624 aerosys-order-2011-sce-1624" class="title-link">AeroSys: Order (2011-SCE-1624)

67

Order Module--DOE Order 225.1B, ACCIDENT INVESTIGATIONS  

Broader source: Energy.gov [DOE]

DOE O 225.1B prescribes organizational responsibilities, authorities, and requirements for conducting investigations of certain accidents occurring at DOE sites, facilities, areas, operations, and...

68

DOE Order Self Study Modules - DOE O 451.1B National Environmental Policy Act Compliance Program  

Broader source: Energy.gov (indexed) [DOE]

1.1B 1.1B NATIONAL ENVIRONMENTAL POLICY ACT COMPLIANCE PROGRAM ALBUQUERQUE OPERATIONS OFFICE Change No: 1 DOE O 451.1B Level: Familiar Date: 6/15/01 1 DOE O 451.1B NATIONAL ENVIRONMENTAL POLICY ACT (NEPA) COMPLIANCE PROGRAM FAMILIAR LEVEL _________________________________________________________________________ OBJECTIVES Given DOE O 451.1B, you will be able to do the following: 1. List the objectives of DOE O 451.1B, National Environmental Policy Act Compliance Program. 2. State the requirements for all DOE elements specified in this Order. 3. Explain why this Order does not contain any requirements for contractors. 4. List the responsibilities associated with this Order for these positions: § Secretarial Officer and head of field organization

69

Order Module--DOE O 420.1B, FACILITY SAFETY | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

DOE O 420.1B, FACILITY SAFETY DOE O 420.1B, FACILITY SAFETY Order Module--DOE O 420.1B, FACILITY SAFETY To ensure that new DOE hazard category 1, 2, and 3 nuclear facilities are designed and constructed in a manner that ensures adequate protection to the public, workers, and the environment from nuclear hazards. To ensure that major modifications to hazard category 1, 2, and 3 nuclear facilities comply with the design and construction requirements for new hazard category 1, 2, and 3 nuclear facilities. To ensure that new DOE nuclear reactors comply with the requirements of DOE O 420.1B and the design requirements of DOE O 5480.30, Nuclear Reactor Safety Design Criteria. DOE Order Self Study Modules - DOE O 420.1B Facility Safety More Documents & Publications Order Module--DOE O 420.2B, SAFETY OF ACCELERATOR FACILITIES

70

Frequently Asked Questions Regarding DOE Order 420.1C, Facility Safety  

Broader source: Energy.gov [DOE]

Frequently Asked Questions Regarding DOE Order 420.1C, Facility Safety, and its supporting directives, DOE?STD?1020?2012, Natural Phenomena Hazards Analysis and Design Criteria for DOE Facilities, and DOE?STD?1066?2012, Fire Protection

71

Order Module--DOE-HDBK-1203-97, GUIDE TO GOOD PRACTICES FOR TRAINING...  

Office of Environmental Management (EM)

STAFF AND MANAGERS, DOE-HDBK-1204-97, GUIDE TO GOOD PRACTICES FOR THE DEVELOPMENT OF TEST ITEMS,DOE-HDBK-1205-97, GUIDE TO GOOD PRACTICES FOR THE DESIGN, DEVELOPMENT Order...

72

Order Module--DOE-HDBK-1203-97, GUIDE TO GOOD PRACTICES FOR TRAINING OF  

Broader source: Energy.gov (indexed) [DOE]

Order Module--DOE-HDBK-1203-97, GUIDE TO GOOD PRACTICES FOR Order Module--DOE-HDBK-1203-97, GUIDE TO GOOD PRACTICES FOR TRAINING OF TECHNICAL STAFF AND MANAGERS, DOE-HDBK-1204-97, GUIDE TO GOOD PRACTICES FOR THE DEVELOPMENT OF TEST ITEMS,DOE-HDBK-1205-97, GUIDE TO GOOD PRACTICES FOR THE DESIGN, DEVELOPMENT Order Module--DOE-HDBK-1203-97, GUIDE TO GOOD PRACTICES FOR TRAINING OF TECHNICAL STAFF AND MANAGERS, DOE-HDBK-1204-97, GUIDE TO GOOD PRACTICES FOR THE DEVELOPMENT OF TEST ITEMS,DOE-HDBK-1205-97, GUIDE TO GOOD PRACTICES FOR THE DESIGN, DEVELOPMENT The familiar level of this module is divided into four sections. In the first section, the module will present DOE-HDBK-1203-97, Training Program for Technical Staff Personnel, which covers the different types of training available to technical staff personnel; section two, DOE-HDBK-1205-97,

73

DOE Order Self Study Modules - DOE O 422.1, Conduct of Operations  

Broader source: Energy.gov (indexed) [DOE]

422.1 422.1 CONDUCT OF OPERATIONS DOE O 422.1 Conduct of Operations Familiar Level June 2011 1 June 2011 DOE O 422.1 CONDUCT OF OPERATIONS FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to answer the following questions: 1. What is the purpose of DOE O 422.1, Conduct of Operations? 2. What are the typical methods of implementing DOE O 422.1 guidelines? 3. What are the specific requirements as described in attachment 2 of DOE O 422.1? 4. How do the DOE Technical Standards support the specific requirements in DOE O 422.1 Note: If you think that you can complete the practice at the end of this level without working through the instructional material and/or the examples, complete the practice

74

DOE Order Self Study Modules - DOE O 433.1B, Maintenance Management Program for DOE Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

3.1B 3.1B MAINTENANCE MANAGEMENT PROGRAM FOR DOE NUCLEAR FACILITIES DOE O 433.1B Familiar Level August 2011 1 DOE O 433.1B MAINTENANCE MANAGEMENT PROGRAM FOR DOE NUCLEAR FACILITIES FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources, you will be able to answer the following questions: 1. What is the objective of DOE O 433.1B, Maintenance Management Program for DOE Nuclear Facilities? 2. What is the purpose for quantitative indicators in maintenance management? 3. What are three types of environmental controls included in a maintenance shop? 4. What is the relationship between DOE G 433.1-1 and DOE O 433.1A? 5. What is the purpose for post-maintenance testing? 6. What is the objective of a good equipment maintenance history program?

75

Accelerator Facility Safety Implementation Guide for DOE Order 420.2C, Safety of Accelerator Facilities  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This is a guide to understanding and meeting the requirements of DOE Order 420.2C and shares lessons learned based on valuable experience within the community.

2013-08-30T23:59:59.000Z

76

Order Module--DOE O 231.1B, ENVIRONMENT, SAFETY, AND HEALTH REPORTING...  

Broader source: Energy.gov (indexed) [DOE]

and health issues as required by law, or regulations, or in support of United States political commitments to the International Atomic Energy Agency (IAEA). DOE Order Self Study...

77

Evaluation of the Cask Transportation Facility Modifications (CTFM) compliance to DOE order 6430.1A  

SciTech Connect (OSTI)

This report was prepared to evaluate the compliance of Cask Transportation Facility Modifications (CTFM) to DOE Order 6430.1A.

ARD, K.E.

1999-07-14T23:59:59.000Z

78

DOE Order Self Study Modules - DOE O 231.1A Environment, Safety, and Health Reporting  

Broader source: Energy.gov (indexed) [DOE]

231.1B 231.1B ENVIRONMENT, SAFETY, AND HEALTH REPORTING DOE O 231.1B Familiar Level August 2011 1 DOE O 231.B ENVIRONMENT, SAFETY, AND HEALTH REPORTING FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to answer the following questions: 1. What is the purpose of DOE O 231.1B? 2. Who must be provided limited access to OSHA Form No. 300? 3. What happens to accident records when the contract between DOE and one of its contractors is terminated? 4. Under what conditions must a work-related injury be reported to the Chief Health, Safety and Security Officer? 5. What is the purpose of the radiological source registry and tracking database? 6. Which DOE position is responsible to report total hours worked by DOE employees each

79

DOE Order Self Study Modules - DOE STD 1073-2003, Configuration Management  

Broader source: Energy.gov (indexed) [DOE]

73-2003 73-2003 CONFIGURATION MANAGEMENT DOE -STD-1073-2003 Familiar Level August 2011 1 DOE-STD-1073-2003 CONFIGURATION MANAGEMENT FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources, you will be able to answer the following questions: 1. What is the purpose of DOE-STD-1073-2003? 2. What are the objectives of configuration management? 3. To what type of DOE facility does DOE-STD-1073-2003 apply? 4. What is the first set of structures, systems, and components (SSCs) that must be included in a configuration management program? 5. What is a work control process? 6. What is the objective of change control? 7. What are three elements that a technical review is designed to verify? 8. What three elements should be included in a design basis review?

80

DOE Order 420.1B/1C Crosswalk Matrix  

Broader source: Energy.gov (indexed) [DOE]

20.1B/1C Crosswalk Matrix 20.1B/1C Crosswalk Matrix Page 1 of 90 February 26, 2013 Citation (420.1C) Original Requirement (O 420.1B, Chg 1, dated 4-19-10) Revised Requirement (O 420.1C, 12-04-2012) Comments 1. 1. OBJECTIVES. To establish facility and programmatic safety requirements for Department of Energy (DOE), including the National Nuclear Security Administration (NNSA), for- a. nuclear and explosives safety design criteria, b. fire protection, c. criticality safety, d. natural phenomena hazards (NPH) mitigation, and e. the System Engineer Program. 1. OBJECTIVE. To establish facility and programmatic safety requirements for the Department of Energy(DOE), including the National Nuclear Security Administration (NNSA), for: a. Nuclear safety design criteria;

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

DOE Awards Small Business Task Order for Technical Support to the Office of  

Broader source: Energy.gov (indexed) [DOE]

DOE Awards Small Business Task Order for Technical Support to the DOE Awards Small Business Task Order for Technical Support to the Office of Environmental Management DOE Awards Small Business Task Order for Technical Support to the Office of Environmental Management June 27, 2013 - 12:00pm Addthis Media Contact Lynette Chafin, 513-246-0461 Lynette.Chafin@emcbc.doe.gov Cincinnati - The Department of Energy (DOE) today awarded a task order for technical support services to TerranearPMC, LLC of Exton, Pennsylvania for support services to the DOE Office of Environmental Management. The Department will issue a time & materials task order with a two-year base period and a one-year option of performance period of three years issued from the master Indefinite Delivery/Indefinite Quantity (ID/IQ) contract with a not-to-exceed value of $2,497,805.40.

82

"Order Module--DOE O 442.1, DEPARTMENT OF ENERGY EMPLOYEE CONCERNS PROGRAM  

Broader source: Energy.gov (indexed) [DOE]

"Order Module--DOE O 442.1, DEPARTMENT OF ENERGY EMPLOYEE CONCERNS "Order Module--DOE O 442.1, DEPARTMENT OF ENERGY EMPLOYEE CONCERNS PROGRAM "Order Module--DOE O 442.1, DEPARTMENT OF ENERGY EMPLOYEE CONCERNS PROGRAM The familiar level of this module is divided into two sections. In the first section, we will discuss the objectives, requirements, responsibilities, and definitions that are contained in the Order. In the second section, we will discuss the Guide. There is only one level of instruction for this Order. You will not be required to complete a practice for this module. Before continuing, you should obtain a copy of DOE O 442.1, DOE Employee Concerns Program, and its companion guide. Copies of these documents are available on the Office of Management and Administration's Web site at http://www.directives.doe.gov or though the course manager. It is not

83

DOE Order Program and Project Management for the Acquisition...  

Office of Environmental Management (EM)

is to provide the Department of Energy's federal project directors (FPDs) with the knowledge, methodologies and tools needed to meet Order 413.3A's requirement that they plan,...

84

DOE Order Self Study Modules - DOE STD 1098-2008, Radiological Control  

Broader source: Energy.gov (indexed) [DOE]

STD-1098-2008 STD-1098-2008 DOE STANDARD: RADIOLOGICAL CONTROL DOE-STD-1098-2008 Familiar Level August 2011 1 DOE-STD-1098-2008 RADIOLOGICAL CONTROL FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to answer the following questions: 1. What is the purpose of DOE-STD-1098-2008? 2. To which DOE position is the authority and responsibility to establish a comprehensive and effective radiological control training program assigned? 3. What is the definition of the term -total effective dose?‖ 4. What is the definition of the term -lifetime control level?‖ 5. What are three trigger levels that require a formal radiological review of work activities?

85

DOE Order Self Study Modules - DOE O 442.1 Department of energy Employee Concerns Program  

Broader source: Energy.gov (indexed) [DOE]

2.1 2.1 DEPARTMENT OF ENERGY EMPLOYEE CONCERNS PROGRAM ALBUQUERQUE OPERATIONS OFFICE Change No: 0 DOE O 442.1 Level: Familiar Date: 6/15/01 1 DOE O 442.1 DOE EMPLOYEE CONCERNS PROGRAM FAMILIAR LEVEL _________________________________________________________________________ OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to perform the following: 1. State three examples of criteria that should be used to assess the significance of an employee's concern. 2. Describe three classifications of employee occupational safety and health concerns that are used for determining safety significance. 3. Discuss the objective of implementing DOE O 442.1, DOE Employee Concerns Program. 4. Discuss the four alternatives for processing concerns.

86

Department of Energy Technical Standards Program - Order DOE 1300.2A  

Broader source: Energy.gov (indexed) [DOE]

Washington, D.C. Washington, D.C. SUBJECT: DEPARTMENT OF ENERGY ORDER DOE 1300.2A 5-19-92 TECHNICAL STANDARDS PROGRAM 1. 2. 3. 4. 5. PURPOSE. This Order sets forth policy, assigns responsibility, and provides requirements for development and application of technical standards in Department of Energy (DOE) facilities, programs, and projects; provides for participation in non-Government standards bodies (NGSBS); for establishment of a DOE Technical Standards Program; and assigns the responsibility for the management of the DOE-wide program. The principle function of this Order is to establish a DOE-wide technical standards program. This includes: a. Ensuring the DOE-wide coordination of technical standards; b. Enhancing standards availability to all DOE elements; Sharing relevant standards information;

87

Order Module--DOE STD-1098-2008, DOE STANDARD: RADIOLOGICAL CONTROL  

Broader source: Energy.gov [DOE]

"The radiological control program discussed in DOE-STD-1098-2008 goes beyond the scope of, and includes more details than, the documented radiation protection program (RPP) required by 10 CFR 835, ...

88

DOE Awards Small Business Task Order for Technical Support to the Office of  

Broader source: Energy.gov (indexed) [DOE]

DOE Awards Small Business Task Order for Technical Support to the DOE Awards Small Business Task Order for Technical Support to the Office of Environmental Management DOE Awards Small Business Task Order for Technical Support to the Office of Environmental Management July 1, 2013 - 12:00pm Addthis Media Contact Bill Taylor, 803-952-8564 bill.taylor@srs.gov Cincinnati - The Department of Energy (DOE) today awarded a task order for technical support services to Boston Government Services, LLC of Lenoir City, Tennessee for support services to the DOE Office of Environmental Management. The time & materials task order will be issued from the master Indefinite Delivery/Indefinite Quantity (ID/IQ) contract with a $1 million value and a one-year period of performance. Boston Government Services, LLC is a small-disadvantaged business under the

89

Order Module--DOE O 420.2B, SAFETY OF ACCELERATOR FACILITIES | Department  

Broader source: Energy.gov (indexed) [DOE]

420.2B, SAFETY OF ACCELERATOR FACILITIES 420.2B, SAFETY OF ACCELERATOR FACILITIES Order Module--DOE O 420.2B, SAFETY OF ACCELERATOR FACILITIES This module will discuss the objectives and requirements associated with the Order and the contractor requirements document. We have provided an example to help familiarize you with the material. The example will also help prepare you for the practice at the end of this module and for the criterion test. Before continuing, you should obtain a copy of the Order at DOE Directives, Regulations, and Standards Portal Home Page or through the course manager. You may need to refer to these documents to complete the example, practice, and criterion test. DOE Order Self Study Modules - DOE O 420.1B Facility Safety More Documents & Publications Order Module--DOE O 420.1B, FACILITY SAFETY

90

DOE Order Self Study Modules - DOE O 151.1C Comprehensive Emergency Management System  

Broader source: Energy.gov (indexed) [DOE]

O 151.1C O 151.1C COMPREHENSIVE EMERGENCY MANAGEMENT SYSTEM NATIONAL NUCLEAR SECURITY ADMINISTRATION SERVICE CENTER Change No: 3 DOE O 151.1C Level: Familiar Date: 12/1/08 1 DOE O 151.1C COMPREHENSIVE EMERGENCY MANAGEMENT SYSTEM FAMILIAR LEVEL _________________________________________________________________________ OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to: 1. List the objectives of DOE O 151.1C, Comprehensive Emergency Management System (EMS); 2. Describe the responsibilities assigned to the following positions or groups for implementation and management of the EMS: Cognizant/field element managers Site/facility managers 3. State the purpose of a hazard survey; 4. List three phases of the planning process that should be addressed in an

91

DOE Order Self Study Modules - DOE O 435.1 Radioactive Waste Management  

Broader source: Energy.gov (indexed) [DOE]

5.1 5.1 RADIOACTIVE WASTE MANAGEMENT ALBUQUERQUE OPERATIONS OFFICE Change No: 0 DOE O 435.1 Level: Familiar Date: 6/15/01 1 DOE O 435.1 RADIOACTIVE WASTE MANAGEMENT FAMILIAR LEVEL _________________________________________________________________________ OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to 1. Discuss the purpose and scope of DOE O 435.1, Radioactive Waste Management. Note: If you think that you can complete the practice at the end of this level without working through the instructional material and/or the examples, complete the practice now. The course manager will check your work. You will need to complete the practice in this level successfully before taking the criterion test.

92

DOE Awards Task Order for Disposal of Los Alamos National Lab Waste |  

Broader source: Energy.gov (indexed) [DOE]

DOE Awards Task Order for Disposal of Los Alamos National Lab Waste DOE Awards Task Order for Disposal of Los Alamos National Lab Waste DOE Awards Task Order for Disposal of Los Alamos National Lab Waste November 13, 2013 - 12:00pm Addthis Media Contact Bill Taylor, 803-952-8564 bill.taylor@srs.gov Cincinnati - The Department of Energy (DOE) today awarded a task order in support of the Los Alamos National Laboratory Legacy Waste Project to Waste Control Specialists (WCS) of Andrews, Texas under the Environmental Management (EM) Low-Level and Mixed Low-Level Waste Disposal Indefinite Delivery/Indefinite Quantity (ID/IQ) Master Contract. This is a fixed-price task order based on pre-established rates with a $2,225,140 value and has a one-year performance period. The work to be performed under this task order includes the receipt and

93

"Order Module--DOE O 426.2, PERSONNEL SELECTION, TRAINING, QUALIFICATION,  

Broader source: Energy.gov (indexed) [DOE]

"Order Module--DOE O 426.2, PERSONNEL SELECTION, TRAINING, "Order Module--DOE O 426.2, PERSONNEL SELECTION, TRAINING, QUALIFICATION, AND CERTIFICATION REQUIREMENTS FOR DOE NUCLEAR FACILITIES "Order Module--DOE O 426.2, PERSONNEL SELECTION, TRAINING, QUALIFICATION, AND CERTIFICATION REQUIREMENTS FOR DOE NUCLEAR FACILITIES "To establish selection, training, qualification, and certification requirements for contractor personnel who can impact the safety basis through their involvement in the operation, maintenance, and technical support of hazard category 1, 2, and 3 nuclear facilities. The systematic approach to training as defined in the contractor requirements document (CRD) of DOE O 426.2 is designed to ensure that these personnel have the requisite knowledge, skills, and abilities to properly perform work in accordance

94

Order Module--DOE O 151.1C, COMPREHENSIVE EMERGENCY MANAGEMENT SYSTEM |  

Broader source: Energy.gov (indexed) [DOE]

151.1C, COMPREHENSIVE EMERGENCY MANAGEMENT 151.1C, COMPREHENSIVE EMERGENCY MANAGEMENT SYSTEM Order Module--DOE O 151.1C, COMPREHENSIVE EMERGENCY MANAGEMENT SYSTEM The familiar level of this module is designed to summarize the basic information in DOE O 151.1C, Comprehensive Emergency Management System. This module is divided into two sections. in the first section, we will discuss the objectives and responsibilities of DOE O 151.1C, Comprehensive Emergency Management System. In the second section, we will discuss the requirements included in chapters III through XI in the Order. The information provided will meet the relevant requirements in the following DOE Functional Area Qualification Standards: DOE-STD-1177-2004, Emergency Management DOE-STD-1151-2002, Facility Representative DOE-STD-1137-2007, Fire Protection Engineering

95

ORDER  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Approved: 6-27-2011 PROTECTION PROGRAM OPERATIONS U.S. DEPARTMENT OF ENERGY Office of Health, Safety and Security DOE O 473.3 DOE O 473.3 1 6-27-11 PROTECTION PROGRAM OPERATIONS 1. PURPOSE. This Order establishes requirements for the management and operation of the Department of Energy (DOE) Federal Protective Forces (FPF), Contractor Protective Forces (CPF), and the Physical Security of property and personnel under the cognizance of DOE. The order does this by combining into one Protection Program Operations (PPO) order the baseline requirements which were contained in the manuals for physical protection, CPF, and FPF. This Order establishes requirements for the physical protection of interests under DOE's purview ranging from facilities, buildings,

96

Microsoft Word - doe_mirant_order_sierraclub.doc  

Broader source: Energy.gov (indexed) [DOE]

February 20 February 20 th , 2006 Mr. Lawrence Mansueti Permitting, Siting, and Analysis Division Office of Electricity Delivery and Energy Reliability Department of Energy 1000 Independence Avenue, SW Washington, DC 20585-0119 Dear Mr. Mansueti, This letter is in response to the Department of Energy Emergency Order to Resume Limited Operation at the Potomac River Generating Station, Alexandria, VA, in Response to Electricity Reliability Concerns in Washington, DC. For over 50 years, and as indicated by Mirant's own recent modeling analysis, citizens in the city of Alexandria have been exposed to significant health risks, including concentrations of nitrogen oxides (NO x ), sulfur dioxide (SO 2 ), and particulate matter with aerodynamic diameter less than 10 microns (PM

97

Order Module--DOE O 430.1B, REAL PROPERTY ASSET MANAGEMENT | Department of  

Broader source: Energy.gov (indexed) [DOE]

30.1B, REAL PROPERTY ASSET MANAGEMENT 30.1B, REAL PROPERTY ASSET MANAGEMENT Order Module--DOE O 430.1B, REAL PROPERTY ASSET MANAGEMENT "The objective of DOE O 430.1B, Real Property Asset Management, is to establish a corporate, holistic, and performance-based approach to real property life-cycle asset management that links real property asset planning, programming, budgeting, and evaluation to program mission projections and performance outcomes. To accomplish the objective, this Order identifies requirements and establishes reporting mechanisms and responsibilities for real property asset management. This Order implements DOE P 580.1, Management Policy for Planning, Programming, Budgeting, Operation, Maintenance and Disposal of Real Property, dated 5/20/02. DOE Order Self Study Modules - DOE O 430.1B Real Property Asset Management

98

DOE Order Self Study Modules - DOE G 441.1-1C Radiation Protection Programs Guide  

Broader source: Energy.gov (indexed) [DOE]

41.1-1C 41.1-1C RADIATION PROTECTION PROGRAMS GUIDE NATIONAL NUCLEAR SECURITY ADMINISTRATION LEARNING AND CAREER DEVELOPMENT DEPARTMENT Change No: 1 DOE G 441.1-1C Level: Familiar Date: 12/1/08 1 DOE G 441.1-1C, RADIATION PROTECTION PROGRAMS GUIDE FAMILIAR LEVEL _________________________________________________________________________ OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to 1. Match radiation protection-related terms to their definitions; 2. Discuss the elements that should be taken into consideration to determine the likelihood of an individual receiving a dose in excess of a regulatory monitoring threshold; 3. Give three examples of criteria that should trigger a formal as-low-as-is-

99

DOE Order Self Study Modules - DOE O 430.1B Real Property Asset Management  

Broader source: Energy.gov (indexed) [DOE]

0.1B 0.1B REAL PROPERTY ASSET MANAGEMENT NATIONAL NUCLEAR SECURITY ADMINISTRATION SERVICE CENTER Change No: 1 DOE: O 430.1B Level: Familiar Date: 12/1/04 1 DOE O 430.1B REAL PROPERTY ASSET MANAGEMENT FAMILIAR LEVEL _________________________________________________________________________ OBJECTIVES Given the familiar level of this module and the resources, you will be able to perform the following: 1. State when a site is required to have and maintain a ten-year site plan (TYSP). What is needed when a TYSP is not required? 2. Discuss contractor requirements for real property asset planning. 3. Discuss the vehicles used to establish land-use planning and management. 4. Define the term "value engineering." 5. Discuss how repair costs associated with real property asset deficiencies are

100

Introduction to DOE Order 435.1 Low Level Radioactive Waste Disposal Requirements  

Broader source: Energy.gov [DOE]

Introduction to DOE Order 435.1 Low Level Radioactive Waste Disposal Requirements Christine Gelles*, U.S. Department of Energy ; Edward Regnier, U.S. Department of Energy; Andrew Wallo, U.S. Department of Energy Abstract: The Atomic Energy Act gives the U.S. Department of Energy (US DOE), the authority to regulate the management of radioactive waste generated by US DOE. This session will discuss DOE Order 435.1, which is protective of workers, public, and environment through specific requirements for the generation, treatment, storage, and disposal of US DOE radioactive waste. The Order is divided into four chapters: General Requirements, High-Level Waste, Transuranic Waste and Low-Level Waste. The requirements are consistent with existing promulgated Federal requirements but are specific to waste generated and disposed at US DOE facilities. A technical standard with requirements for documentation supporting the Disposal Authorization for a facility is also being prepared as well as a guide to accompany the Order. US DOE is in the process of updating the Order to maintain consistency with current practices and to increase efficiency in waste management. The draft Order will be available for public comment prior to being finalized.

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Order Module--DOE-STD-1063-2011, FACILITY REPRESENTATIVES | Department of  

Broader source: Energy.gov (indexed) [DOE]

DOE-STD-1063-2011, FACILITY REPRESENTATIVES DOE-STD-1063-2011, FACILITY REPRESENTATIVES Order Module--DOE-STD-1063-2011, FACILITY REPRESENTATIVES The familiar level of this module is divided into three sections. The first section addresses the purpose and scope of DOE-STD-1063-2011, the purpose of the FR program, and the duties, responsibilities, and authorities of FRs and other key personnel. In the second section, the requirements of the FR program are discussed. The third section covers the three appendices of this standard: FR performance indicators, an FR program assessment guide, and the process to determine FR staffing. We have provided examples and a practice to help familiarize you with the material. The practice will also help prepare you for the criterion test. DOE Order Self Study Modules - DOE STD 1063, Facility Representatives

102

Order Module--DOE O 452.1D, NUCLEAR EXPLOSIVE AND WEAPON SURETY PROGRAM,  

Broader source: Energy.gov (indexed) [DOE]

Order Module--DOE O 452.1D, NUCLEAR EXPLOSIVE AND WEAPON SURETY Order Module--DOE O 452.1D, NUCLEAR EXPLOSIVE AND WEAPON SURETY PROGRAM, DOE O 452.2D, NUCLEAR EXPLOSIVE SAFETY Order Module--DOE O 452.1D, NUCLEAR EXPLOSIVE AND WEAPON SURETY PROGRAM, DOE O 452.2D, NUCLEAR EXPLOSIVE SAFETY "To prevent accidents and inadvertent or unauthorized use of U.S. nuclear weapons and nuclear explosives. In conjunction with the Department of Defense (DoD), to protect the public health and safety by providing dual-agency judgment and responsibility for the safety, security, and use control (surety) of nuclear weapons. To establish nuclear explosive surety standards and nuclear weapon design surety requirements. To address surety vulnerabilities during all phases of the nuclear weapon life cycle and to upgrade surety during weapon stockpile refurbishments and/or new weapon

103

Order Module--DOE O 451.1B, NATIONAL ENVIRONMENTAL POLICY ACT COMPLIANCE  

Broader source: Energy.gov (indexed) [DOE]

51.1B, NATIONAL ENVIRONMENTAL POLICY ACT 51.1B, NATIONAL ENVIRONMENTAL POLICY ACT COMPLIANCE PROGRAM Order Module--DOE O 451.1B, NATIONAL ENVIRONMENTAL POLICY ACT COMPLIANCE PROGRAM DOE O 451.1B, National Environmental Policy Act Compliance Program, replaces DOE O 451.1A of the same name. DOE O 451.1B is ten pages long. Due to the concise nature of this Order, this module will be limited to one level. To complete this module and satisfy the requirements for qualification 1. Obtain a copy of DOEO 451.1B. A copy of this document is available on the Office of Management and Administration's Web site at http://www.directives.doe.gov or through the course manager. 2. Review the objectives, requirements, and responsibilities sections of the Order. 3. When you are ready, ask the course manager for the criterion test.

104

Order Module--DOE O 425.1D, VERIFICATION OF READINESS TO START UP OR  

Broader source: Energy.gov (indexed) [DOE]

DOE O 425.1D, VERIFICATION OF READINESS TO START UP DOE O 425.1D, VERIFICATION OF READINESS TO START UP OR RESTART NUCLEAR FACILITIES Order Module--DOE O 425.1D, VERIFICATION OF READINESS TO START UP OR RESTART NUCLEAR FACILITIES "The familiar level of this module is divided into three sections. In the first section we will discuss the purpose of DOE O 425.1D and the requirements for 1) determining the level of readiness review (RR), 2) determining the startup authorization authority (SAA), and 3) the startup notification report. In the second section we will discuss 1) the requirements applicable to DOE ORRs and DOE RAs, and 2) the core requirements. In the third section we will discuss the 1) requirements for DOE field element and headquarters line management oversight of the startup or restart process, 2) requirements for the records management program, and

105

Order Module--DOE G 450.4-1B, INTEGRATED SAFETY MANAGEMENT SYSTEM GUIDE |  

Broader source: Energy.gov (indexed) [DOE]

G 450.4-1B, INTEGRATED SAFETY MANAGEMENT SYSTEM G 450.4-1B, INTEGRATED SAFETY MANAGEMENT SYSTEM GUIDE Order Module--DOE G 450.4-1B, INTEGRATED SAFETY MANAGEMENT SYSTEM GUIDE This Guide has two purposes. One purpose is to assist DOE contractors in developing, describing, and implementing an ISMS to comply with DOE P 450.4, Safety Management system Policy; DOE P 450.5, Line Environment, Safety, and Health Oversight; DOE P 450.6, Secretarial Policy Statement Environment, Safety and Health; DOE P 411.1, Safety Management FRAM; and the following provisions of the DEAR: 48 CFR 970.5223-1, which requires integration of environment, safety, and health into work planning and execution; 48 CFR 970.5204-2, which deals with laws, regulations, and DOE directives; and 48 CFR 970.1100-1, which requires performance-based contracting.

106

Order Module--DOE O 458.1, RADIATION PROTECTION OF THE PUBLIC AND THE  

Broader source: Energy.gov (indexed) [DOE]

58.1, RADIATION PROTECTION OF THE PUBLIC AND 58.1, RADIATION PROTECTION OF THE PUBLIC AND THE ENVIRONMENT Order Module--DOE O 458.1, RADIATION PROTECTION OF THE PUBLIC AND THE ENVIRONMENT The familiar level of this module is divided into two sections. In the first section, we will discuss the objectives and definitions related to the Order. In the second section, we will discuss the requirements in section four of the Order and the responsibilities of the field element managers for compliance with DOE O 458.1. We have provided examples and practices throughout the module to help familiarize you with the material. The practice will also help prepare you for the criterion test. DOE Order Self Study Modules - DOE O 458.1, Radiation Protection of the Public and the Environment More Documents & Publications

107

Order Module--DOE O 420.2B, SAFETY OF ACCELERATOR FACILITIES...  

Energy Savers [EERE]

also help prepare you for the practice at the end of this module and for the criterion test. Before continuing, you should obtain a copy of the Order at DOE Directives,...

108

Impact of DOE Orders on Waste Management Operation. Volume 1: [Final report  

SciTech Connect (OSTI)

Department of Energy Orders are the internal documents which govern the management of all Department of Energy facilities and operations. DOE Orders are the vehicles by which Federal and state laws and regulations are applied to Department of Energy activities. A selected set of 22 Department of Energy Orders was reviewed to identify the applicability and impact of each Order on waste management operations at Los Alamos National Laboratory. Of the 22 Orders reviewed, five set forth requirements which have a high degree of impact on waste management activities. Eight Orders have a moderate degree of impact on waste management activities, and the remaining nine Orders have a low degree of impact.

Klein, R.B.; Jennrich, E.A.; Shuman, R.; Sandquist, G.M. [Rogers and Associates Engineering Corp., Salt Lake City, UT (United States); Rutz, A.C.; Littleton, M.W.; McCauce, C.H. [Wastren, Inc., Idaho Falls, ID (United States)

1989-09-01T23:59:59.000Z

109

Order Module--DOE O 231.1B, ENVIRONMENT, SAFETY, AND HEALTH REPORTING |  

Broader source: Energy.gov (indexed) [DOE]

O 231.1B, ENVIRONMENT, SAFETY, AND HEALTH O 231.1B, ENVIRONMENT, SAFETY, AND HEALTH REPORTING Order Module--DOE O 231.1B, ENVIRONMENT, SAFETY, AND HEALTH REPORTING To ensure the DOE receives timely and accurate information about events that have affected or could adversely affect the health, safety, and security of the public or workers, the environment, the operations of DOE facilities, or the credibility of the Department. This will be accomplished through timely collection, reporting, analysis, and dissemination of data pertaining to environment, safety, and health issues as required by law, or regulations, or in support of United States political commitments to the International Atomic Energy Agency (IAEA). DOE Order Self Study Modules - DOE O 231.1A Environment, Safety, and Health Reporting

110

DOE Order 144.1: Department of Energy American Indian Tribal Government Interactions and Policy (2009)  

Broader source: Energy.gov (indexed) [DOE]

www.directives.doe.gov Office of Intergovernmental and Tribal Affairs www.directives.doe.gov Office of Intergovernmental and Tribal Affairs U.S. Department of Energy ORDER Washington, D.C. Approved: 1-16-09 Admin Chg 1: 11-6-09 SUBJECT: DEPARTMENT OF ENERGY AMERICAN INDIAN TRIBAL GOVERNMENT INTERACTIONS AND POLICY 1. PURPOSE. This Order communicates Departmental, programmatic, and field responsibilities for interacting with American Indian Governments and transmits the Department of Energy's (DOE) American Indian and Alaska Native Tribal Government Policy (hereafter "Indian Policy") including its guiding principles, and transmits the Framework for Implementation of the Policy. 2. CANCELLATION. DOE O 1230.2, American Indian Tribal Government Policy, dated 4-8-92. Cancellation of a directive does not, by itself, modify or otherwise affect any

111

Order Module--DOE O 231.1B, ENVIRONMENT, SAFETY, AND HEALTH REPORTING |  

Broader source: Energy.gov (indexed) [DOE]

231.1B, ENVIRONMENT, SAFETY, AND HEALTH 231.1B, ENVIRONMENT, SAFETY, AND HEALTH REPORTING Order Module--DOE O 231.1B, ENVIRONMENT, SAFETY, AND HEALTH REPORTING To ensure the DOE receives timely and accurate information about events that have affected or could adversely affect the health, safety, and security of the public or workers, the environment, the operations of DOE facilities, or the credibility of the Department. This will be accomplished through timely collection, reporting, analysis, and dissemination of data pertaining to environment, safety, and health issues as required by law, or regulations, or in support of United States political commitments to the International Atomic Energy Agency (IAEA). DOE Order Self Study Modules - DOE O 231.1A Environment, Safety, and Health Reporting More Documents & Publications

112

DOE Order 458.1 Property Clearance Requirements and Factors Considered to Update Its Clearance Limits  

Broader source: Energy.gov [DOE]

DOE Order 458.1 Property Clearance Requirements and Factors Considered to Update Its Clearance Limits Carlos Corredor*, U.S. Department of Energy ;Gustavo Vasquez, U.S. Department of Energy; Derek Favret, U.S. Department of Energy This presentation will provide an explanation of the property clearance requirements contained in DOE O 458.1, including the methods to release or clear property: process knowledge and authorized limits. In addition, it will provide a special focus on the efforts to update the surface guidelines table in DOE directives. In planning to update its property clearance criteria DOE is considering many factors; such as their protectiveness, whether they are dose-based, consistency with voluntary consensus standards and national and international radiation protection recommendations, and consistency with DOE dose constraints. One option being considered is a hybrid approach using a national consensus standard for personal property and DOE derived values for real property.

113

DOE Order 144.1: Department of Energy American Indian Tribal Government  

Broader source: Energy.gov (indexed) [DOE]

Order 144.1: Department of Energy American Indian Tribal Order 144.1: Department of Energy American Indian Tribal Government Interactions and Policy (2009) DOE Order 144.1: Department of Energy American Indian Tribal Government Interactions and Policy (2009) Communicates Departmental, programmatic, and field responsibilities for interacting with American Indian Governments and transmits the Department of Energy's (DOE) American Indian and Alaska Native Tribal Government Policy. DOE Order 144.1 provides direction to all Departmental officials, staff, and contractors regarding fulfillment of trust obligations and other responsibilities arising from Departmental actions which may potentially impact American Indian and Alaska Native traditional, cultural, and religious values and practices; natural resources; treaty and other

114

Development of a process for releasing non-real property under order DOE 5400.5.  

SciTech Connect (OSTI)

It is the policy of the U.S. Department of Energy (DOE) to improve environmental quality and conserve natural and economic resources by, among other things, increasing the reuse and recycle of recoverable materials in order to minimize land disposal of wastes. Consistent with this policy, DOE's Office of Environmental Management believes it is important to pursue strategies for reusing and recycling the large and growing DOE inventory of recoverable non-real property. However, responsible pursuit of such strategies requires careful prior consideration of the available alternatives, given the radiological character of much of the non-real property to be released. Requirements applicable to considerations of this type are established by Order DOE 5400.5, Radiation Protection of the Public and the Environment. This article describes the development and content of a step-by-step process designed to provide confidence that radiological doses to the public from recycle or reuse of released non-real property containing residual radioactive material meet applicable regulatory standards, are as low as reasonably achievable, and meet the requirements in Order DOE 5400.5 for release of such material. The full process, described in the Draft Handbook for Controlling Release for Reuse or Recycle of Non-Real Property Containing Residual Radioactive Material (for interim use and comment), DOE-HDBK-xxxx-97 (June 1997), is available for viewing and downloading at http://www.em.doe.gov/recyc.

Warren, S.; Ranek, N. L.; Hensley, J.; Environmental Assessment; DOE

1998-01-01T23:59:59.000Z

115

ORDER  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Approved: 7-21-2011 SAFEGUARDS AND SECURITY PROGRAM U.S. DEPARTMENT OF ENERGY Office of Health, Safety and Security DOE O 470.4B DOE O 470.4B 1 7-21-11 SAFEGUARDS AND SECURITY PROGRAM 1. PURPOSE. To establish responsibilities for the U.S. Department of Energy (DOE) Safeguards and Security (S&S) Program, and to establish program planning and management requirements for the S&S Program. The requirements identified in this Order and its attachments and appendices are based on national policy promulgated in laws, regulations, Executive Orders, and national standards to prevent unacceptable adverse impacts on national security, the health and safety of DOE and contractor employees, the public, or the environment. 2. CANCELLATIONS. DOE O 470.4A, Safeguards and Security Program, dated 5-25-07;

116

DOE Order 344.1A, Parking at the Forrestal Facility  

Broader source: Energy.gov (indexed) [DOE]

344.1A 344.1A Approved: 11-2-01 Admin Chg 1: 11-19-04 This directive was reviewed and certified as current and necessary by Susan J. Grant, Director, Office of Management, Budget and Evaluation/Chief Financial Officer, 11-19-04. SUBJECT: PARKING 1. OBJECTIVES. To define policies and procedures governing the assignment, use, and management of parking spaces controlled by the Department of Energy (DOE) in the Forrestal Facility. 2. CANCELLATION. This Order cancels HQ O 344.1, Parking, dated 3-5-97. 3. APPLICABILITY. This Order applies to DOE Federal employees, including National Nuclear Security Administration (NNSA) Federal employees, parking at DOE Headquarters in the Forrestal Building. 4. REQUIREMENTS. a. General. It is the policy of DOE that its parking facility be operated in a manner

117

DOE Order Self Study Modules - 10 CFR 830 Safety Basis Documentation  

Broader source: Energy.gov (indexed) [DOE]

Orders Orders Self-Study Program Safety Basis Documentation 10 CFR 830, NUCLEAR SAFETY MANAGEMENT DOE G 421.1-2, IMPLEMENTATION GUIDE FOR USE IN DEVELOPING DOCUMENTED SAFETY ANALYSES TO MEET SUBPART B OF 10 CFR 830 DOE G 423.1.1, IMPLEMENTATION GUIDE FOR USE IN DEVELOPING TECHNICAL SAFETY REQUIREMENTS DOE G 424.1-1, IMPLEMENTATION GUIDE FOR USE IN ADDRESSING UNREVIEWED SAFETY QUESTION REQUIREMENTS DOE-STD-1104-96, REVIEW AND APPROVAL OF NUCLEAR FACILITY SAFETY BASIS DOCUMENTS (DOCUMENTED SAFETY ANALYSES AND TECHNICAL SAFETY REQUIREMENTS) NNSA SERVICE CENTER Change No: 0 Safety Basis Documents Level: Familiar Date: 10/15/03 1 SAFETY BASIS DOCUMENTS FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to:

118

DOE-STD-1034-93; Guide to Good Practices for Timely Orders to Operators  

Broader source: Energy.gov (indexed) [DOE]

4-93 4-93 March 1993 CHANGE NOTICE NO. 1 December 1998 DOE STANDARD GUIDE TO GOOD PRACTICES FOR TIMELY ORDERS TO OPERATORS U.S. Department of Energy AREA MISC Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced from the best available copy. Available to DOE and DOE contractors from ES&H Technical Information Services, U.S. Department of Energy, (800) 473-4375, fax: (301) 903-9823. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 605-6000. Change Notice No. 1 DOE-STD-1034-93 December 1998 Guide to Good Practices for Timely Orders to Operators Page / Section Change p. 10 / Section 4.3

119

DOE Awards Task Order Modification for Support Services to Office of  

Broader source: Energy.gov (indexed) [DOE]

Modification for Support Services to Office Modification for Support Services to Office of Environmental Management DOE Awards Task Order Modification for Support Services to Office of Environmental Management March 11, 2013 - 12:00pm Addthis Media Contact Lynette Chafin, 513-246-0461 Lynette.Chafin@emcbc.doe.gov Cincinnati - The Department of Energy (DOE) today awarded a modification to Task Order DE-DT0005235 to J.G. Management Systems, Inc. of Grand Junction, CO for administrative and program analytical support for the Office of Environmental Management. The task order was awarded under Indefinite Delivery/Indefinite Quantity (ID/IQ) Master Contract. The modification is valued at approximately $3.1M over three years including a one-year base period and two one-year option periods. J.G. Management Systems, Inc. is a small-disadvantaged business

120

Idaho CERCLA Disposal Facility Complex Compliance Demonstration for DOE Order 435.1  

SciTech Connect (OSTI)

This compliance demonstration document provides an analysis of the Idaho CERCLA Disposal Facility (ICDF) Complex compliance with DOE Order 435.1. The ICDF Complex includes the disposal facility (landfill), evaporation pond, administration facility, weigh scale, and various staging/storage areas. These facilities were designed and constructed to be compliant with DOE Order 435.1, Resource Conservation and Recovery act Subtitle C, and Toxic Substances Control Act polychlorinated biphenyl design and construction standards. The ICDF Complex is designated as the Idaho National Laboratory (INL) facility for the receipt, staging/storage, treatment, and disposal of INL Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) waste streams.

Simonds, J.

2007-11-06T23:59:59.000Z

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

ORDER  

Office of Legacy Management (LM)

3-2010 3-2010 SCIENTIFIC AND TECHNICAL INFORMATION MANAGEMENT U.S. DEPARTMENT OF ENERGY Office of Scientific and Technical Information DOE O 241.1B DOE O 241.1B 1 12-13-2010 SCIENTIFIC AND TECHNICAL INFORMATION MANAGEMENT 1. PURPOSE. The U.S. Department of Energy (DOE) produces scientific and technical information (STI) in the course of performing research and development (R&D) and other science and technology activities. The purpose of this directive is to ensure that STI is appropriately managed as part of the DOE mission to enable the advancement of scientific knowledge and technological innovation. Therefore, the objectives of this order are to: a. establish DOE requirements and responsibilities to ensure that Departmental STI

122

ORDER  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DOE O 475.2A Approved: 2-1-11 IDENTIFYING CLASSIFIED INFORMATION U.S. DEPARTMENT OF ENERGY Office of Health, Safety and Security DOE O 475.2A 1 2-1-11 IDENTIFYING CLASSIFIED INFORMATION 1. PURPOSE. To establish the program to identify information classified under the Atomic Energy Act [Restricted Data (RD), Formerly Restricted Data (FRD), and Transclassified Foreign Nuclear Information (TFNI)] or Executive Order (E.O.) 13526 [National Security Information (NSI)], so that it can be protected against unauthorized dissemination. 2. CANCELLATION. DOE O 475.2, Identifying Classified Information, dated 8-28-07, and DOE M 475.1-1B, Manual for Identifying Classified Information, dated 8-28-07. Cancellation of a directive does not, by itself, modify or otherwise affect any contractual

123

Order Module--DOE-STD-1104-2009, REVIEW AND APPROVAL OF NUCLEAR FACILITY  

Broader source: Energy.gov (indexed) [DOE]

DOE-STD-1104-2009, REVIEW AND APPROVAL OF NUCLEAR DOE-STD-1104-2009, REVIEW AND APPROVAL OF NUCLEAR FACILITY SAFETY BASIS AND SAFETY DESIGN BASIS DOCUMENTS Order Module--DOE-STD-1104-2009, REVIEW AND APPROVAL OF NUCLEAR FACILITY SAFETY BASIS AND SAFETY DESIGN BASIS DOCUMENTS The familiar level of this module is divided into two sections that are intended to provide only an overview of the material contained in DOE-STD-1104-2009, which should be consulted for complete information. The first section covers the introduction, applicability, and chapters 1 and 2. The second section covers chapters 3, 4, and 5. We have provided examples throughout the module to help familiarize you with the material. The examples will also help prepare you for the practice at the end of this module and for the criterion test.

124

DOE ESPC TASK ORDER REQUEST FOR PROPOSAL (TO RFP) TEMPLATE (11/20/08)  

Broader source: Energy.gov (indexed) [DOE]

DOE ESPC DOE ESPC TASK ORDER REQUEST FOR PROPOSAL (TO RFP) TEMPLATE (11/20/08) INSTRUCTIONS FOR USING THE TEMPLATE The TO RFP is used to communicate agency- or site-specific terms and conditions for the project to the ESCO. The DOE IDIQ contract permits such revision, per section C.1.3: C.1.3 Unless otherwise stated, all provisions that follow throughout the remaining sections of this master IDIQ contract may be revised within the overall scope of the contract, as necessary (based on the needs and regulations of the agency), in an agency TO Request for Proposals (RFP). The TO RFP becomes a part of the task order, along with the IDIQ and the ESCO's final proposal, and its provisions override those of the IDIQ. Contract sections in the template appear in plain arial font; instructions

125

Hazard Categorization and Accident Analysis Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

he purpose of this DOE Standard is to establish guidance for the preparation and review of hazard categorization and accident analyses techniques as required in DOE Order 5480.23, Nuclear Safety Analysis Reports.

1997-12-12T23:59:59.000Z

126

Order Module--DOE O 414.1D, QUALITY ASSURANCE | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

14.1D, QUALITY ASSURANCE 14.1D, QUALITY ASSURANCE Order Module--DOE O 414.1D, QUALITY ASSURANCE "To ensure that DOE, including NNSA, products and services meet or exceed customers' requirements and expectations. To achieve quality for all work based upon the following principles: All work, as defined in this Order, is conducted through an integrated and effective management system. Management support for planning, organization, resources, direction, and control is essential to quality assurance (QA). Performance and quality improvement require thorough, rigorous assessments and effective corrective actions. All personnel are responsible for achieving and maintaining quality. Risks and adverse mission impacts associated with work processes are minimized while maximizing reliability and performance of work products.

127

DOE ORDER 5480.14, PHASE I - INSTALLATION ASSESSMENT FOR THE BETTIS ATOMIC POWER LABORATORY  

Office of Legacy Management (LM)

DOE ORDER 5480.14, PHASE I - INSTALLATION ASSESSMENT FOR THE BETTIS ATOMIC POWER LABORATORY Prepared for the U.S. Department of Energy by Westinghouse Electric Corporation West Mifflin, Pennsylvania 15122-0079 i' Vendor Contract Number: DE-ACll-76PN00014 : IAELE OF CONTENTS I. Executive Summary ............................................. 2. Introduction .................................................. a. Background......;.........................................i b. Authority .......................................................... : ; c. Purpose I ........................................................ 3 d Scope..................................................~..! e: Methodology...............................................! ........

128

"Order Module--DOE-STD-3009-94, PREPARATION GUIDE FOR U.S. DEPARTMENT OF  

Broader source: Energy.gov (indexed) [DOE]

"Order Module--DOE-STD-3009-94, PREPARATION GUIDE FOR U.S. "Order Module--DOE-STD-3009-94, PREPARATION GUIDE FOR U.S. DEPARTMENT OF ENERGY NONREACTOR NUCLEAR FACILITY "Order Module--DOE-STD-3009-94, PREPARATION GUIDE FOR U.S. DEPARTMENT OF ENERGY NONREACTOR NUCLEAR FACILITY "The familiar level of this module is divided into three sections. The first section is an introduction to DOE-STD-3009-94. In the second section, we will introduce the 17 chapters of a documented safety analysis (DSA). The third section covers the evaluation guideline that appears in appendices 1-5 of the standard. We have provided several examples and practices throughout the module to help familiarize you with the material. The practice will also help prepare you for the criterion test." DOE Order Self Study Modules - DOE-STD-3009-94, Preparation Guide for U.S.

129

A New Class of Magnetic Materials with Novel Structural Order | U.S. DOE  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

A New Class of Magnetic Materials with Novel Structural Order A New Class of Magnetic Materials with Novel Structural Order Basic Energy Sciences (BES) BES Home About Research Facilities Science Highlights Benefits of BES Funding Opportunities Basic Energy Sciences Advisory Committee (BESAC) News & Resources Contact Information Basic Energy Sciences U.S. Department of Energy SC-22/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-3081 F: (301) 903-6594 E: sc.bes@science.doe.gov More Information » June 2013 A New Class of Magnetic Materials with Novel Structural Order The discovery of the first binary magnetic quasicrystals will enable the unraveling of the fundamental relationship between the structure and magnetism in aperiodic materials. Print Text Size: A A A Subscribe FeedbackShare Page

130

DOE Order 435.1 Performance Assessment Savannah River Site | Department of  

Broader source: Energy.gov (indexed) [DOE]

Order 435.1 Performance Assessment Savannah River Site Order 435.1 Performance Assessment Savannah River Site DOE Order 435.1 Performance Assessment Savannah River Site Performance Assessments (PA) are analyses conducted for low level radioactive waste disposal facilities (or appropriate CERCLA documentation for a low level radioactive waste disposal facility), and are critical in determining the nature and extent of the controls that need to be put in place at the facility being evaluated. There are specific requirements for the protection of the public, workers, and environment that are critical to maintaining safe and effective disposal of radioactive waste and the PA is a risk analysis of the potential hazards of disposing of low level radioactive waste. The review and approval of these evaluations is

131

DOE Order Self Study Modules - DOE O 426.2 Personnel Selection, Training, Qualification, and Certification Requirements for DOE Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

6.2 6.2 PERSONNEL SELECTION, TRAINING, QUALIFICATION, AND CERTIFICATION REQUIREMENTS FOR DOE NUCLEAR FACILITIES DOE O 426.2 Familiar Level June 2011 1 DOE O 426.2 PERSONNEL SELECTION, TRAINING, QUALIFICATION, AND CERTIFICATION REQUIREMENTS FOR DOE NUCLEAR FACILITIES FAMILIAR LEVEL ___________________________________________________________________________ OBJECTIVES Given the familiar level of this module and the resources, you will be able answer the following questions: 1. What is the purpose of DOE O 426.2, Personnel Selection, Training, Qualification, and Certification Requirements for DOE Nuclear Facilities? 2. What are the DOE field elements requirements associated with DOE O 426.2? 3. What are the general contractor requirements specified in the contractor requirements

132

Enforcement Action - EA-2003-05 - Consent Order Between US DOE and Flour Fernald  

Broader source: Energy.gov (indexed) [DOE]

18, 2003 18, 2003 Mr. Woodrow Jameson [ ] Fluor Fernald, Inc. P.O. Box 538704 Cincinnati, OH 45252-8704 EA-2003-05 Subject: Consent Order Incorporating Agreement between U.S. Department of Energy and Fluor Fernald, Inc. Dear Mr. Jameson: This letter refers to the Department of Energy's (DOE) evaluation of a recent investigation conducted by Fluor Fernald, Inc. (Fluor Fernald) into the facts and circumstances surrounding an unposted High Radiation Area adjacent to the small concrete building [ ] currently used for thermoluminescent dosimeter (TLD) irradiations. This unposted condition, present during irradiator operations, existed for over a year before discovery by DOE on March 27, 2003. Fluor Fernald reported the deficiency using the

133

Order Module--DOE O 151.1C, COMPREHENSIVE EMERGENCY MANAGEMENT...  

Office of Environmental Management (EM)

Management DOE-STD-1151-2002, Facility Representative DOE-STD-1137-2007, Fire Protection Engineering DOE-STD-1138-2007, Industrial Hygiene DOE-STD-1150-2002, Quality Assurance...

134

DOE-STD-1027-92; Hazard Categorization and Accident Analysis Techniques For Compliance With DOE Order 5480.23, Nuclear Safety Analysis Reports  

Broader source: Energy.gov (indexed) [DOE]

7-92 7-92 December 1992 CHANGE NOTICE NO.1 September 1997 DOE STANDARD HAZARD CATEGORIZATION AND ACCIDENT ANALYSIS TECHNIQUES FOR COMPLIANCE WITH DOE ORDER 5480.23, NUCLEAR SAFETY ANALYSIS REPORTS U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE98001283 Change Notice No. 1 DOE-STD-1027-92

135

DOE Awards Small Business Task Order for Technical Support to the Office of  

Broader source: Energy.gov (indexed) [DOE]

TerranearPMC, LLC of Exton, PA to provide TerranearPMC, LLC of Exton, PA to provide Spent Nuclear Fuel and Excess Nuclear Materials Disposition Planning technical support to the Office of Environmental Management. A time and materials task order will be issued from the master Indefinite Delivery/Indefinite Quantity (ID/IQ) contract with a $1 million value and a three-year period of performance. TerranearPMC, LLC is a small-disadvantaged business under the Small Business Administration's 8(a) Program. The work to be performed on the task order will include: Provide support in the identification and development of new technologies while working collaboratively with DOE's international partners; Provide specialized expertise in resolving technical challenges associated with challenging materials; Provide support for the development and review of National

136

Status Update for Implementing Best Available Technology per DOE Order 5400.5  

SciTech Connect (OSTI)

This report documents the Bechtel BWXT Idaho, LCC, operated facilities at the Idaho National Engineering and Environmental Laboratory that require the Best Available Technology selection process in accordance with Department of Energy Order 5400.5, Chapter II (3), Management and Control of Radioactive Materials in Liquid Discharges.1 This report differs from previous reports in that only those liquid waste streams and facilities requiring the Best Available Technology selection process will be evaluated in detail. In addition, this report will be submitted to the DOE-ID Field Office Manager for approval in accordance with DOE Order 5400.5, Chapter II, Section 3.b.(1). The report also identifies facilities addressed in last years report that do not require the Best Available Technology selection process to be completed. These facilities will not be addressed in future reports. This report reviews the following facilities: Auxiliary Reactor Area Idaho National Engineering and Environmental Laboratory Block Areas Central Facilities Area Idaho Nuclear Technology and Engineering Center Idaho Falls Facilities Power Burst Facility Radioactive Waste Management Complex Test Area North Test Reactor Area. Three facilities (Central Facilities Area Sewage Treatment Plant, Idaho Nuclear Technology and Engineering Center Percolation Ponds and Test Area North/Technical Support Facility Disposal Pond) at the Idaho National Engineering and Environmental Laboratory required documentation of the Best Available Technology selection process. The Idaho Nuclear Technology and Engineering Center Percolation Ponds and Test Area North/Technical Support Facility Disposal Pond discharge wastewater that may contain process-derived radionuclides to a soil column with average radionuclide concentrations below drinking water MCLs. At the request of the Department of Energy Idaho Operations Office, Bechtel BWXT Idaho, LLC has included the 73.5acre Central Facilities Area Sewage Treatment Plant land application site in Section 4 (Facilities Requiring BAT) of this report to ensure the requirements of DOE Order 5400.5, Chapter II, Section 3 are met. The Central Facilities Area Sewage Treatment Plant effluent may contain process-derived radionuclides. However, the average concentrations of these radionuclides are below MCLs.According to DOE guidance, If the liquid waste stream is below MCLs, this indicates that the goals of the Best Available Technology selection process are being met and the liquid waste stream is considered clean water. However, it is necessary to document this through the Best Available Technology selection process.

Lewis, Michael George

2001-09-01T23:59:59.000Z

137

DOE Order Self Study Modules - DOE O 440.1B, Worker Protection Management for DOE (Including the National Nuclear Security Administration) Federal Employees  

Broader source: Energy.gov (indexed) [DOE]

0.1B 0.1B WORKER PROTECTION PROGRAM FOR DOE (INCLUDING THE NATIONAL NUCLEAR SECURITY ADMINISTRATION) FEDERAL EMPLOYEES DOE O 440.1B Familiar Level June 2011 1 DOE O 440.1B WORKER PROTECTION MANAGEMENT FOR DOE (INCLUDING THE NATIONAL NUCLEAR SECURITY ADMINISTRATION) FEDERAL EMPLOYEES FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to answer the following questions: 1. What are the objectives of DOE O 440.1B? 2. What are the requirements that DOE elements must meet according to DOE O 440.1B? 3. What is the hazard prevention/abatement process that must be implemented according to DOE O 440.1B? 4. What are three responsibilities assigned by DOE O 440.1B for heads of field elements?

138

DOE Order Self Study Modules - DOE O 460.1C Packaging and Transportation Safety and DOE O 460.2A Departmental Materials Transportation and Packaging Management  

Broader source: Energy.gov (indexed) [DOE]

60.1C 60.1C PACKAGING AND TRANSPORTATION SAFETY DOE O 460.2A DEPARTMENTAL MATERIALS TRANSPORTATION AND PACKAGING MANAGEMENT DOE O 460.1C and 460.2A Familiar Level June 2011 1 DOE O 460.1C PACKAGING AND TRANSPORTATION SAFETY DOE O 460.2A DEPARTMENTAL MATERIALS TRANSPORTATION AND PACKAGING MANAGEMENT FAMILIAR LEVEL _________________________________________________________________________ OBJECTIVES Given the familiar level of this module and the resources, you will be able to perform the following: 1. What are the objectives of U.S. Department of Energy (DOE) O 460.1C? 2. What is the DOE/National Nuclear Security Administration (NNSA) exemption process in DOE O 460.1C? 3. What are the onsite safety requirements specified by DOE O 460.1C? 4. What are the objectives of DOE O 460.2A?

139

Idaho CERCLA Disposal Facility Complex Compliance Demonstration for DOE Order 435.1  

SciTech Connect (OSTI)

This compliance demonstration document provides an analysis of the Idaho CERCLA Disposal Facility (ICDF) Complex compliance with DOE Order 435.1. The ICDF Complex includes the disposal facility (landfill), evaporation pond, admin facility, weigh scale, decon building, treatment systems, and various staging/storage areas. These facilities were designed and are being constructed to be compliant with DOE Order 435.1, Resource Conservation and Recovery Act Subtitle C, and Toxic Substances Control Act polychlorinated biphenyl design and construction standards. The ICDF Complex is designated as the central Idaho National Laboratory (INL) facilityyy for the receipt, staging/storage, treatment, and disposal of INL Comprehensive Environmental Response, Compensation and Liability Act (CERCLA) waste streams. This compliance demonstration document discusses the conceptual site model for the ICDF Complex area. Within this conceptual site model, the selection of the area for the ICDF Complex is discussed. Also, the subsurface stratigraphy in the ICDF Complex area is discussed along with the existing contamination beneath the ICDF Complex area. The designs for the various ICDF Complex facilities are also included in this compliance demonstration document. These design discussions are a summary of the design as presented in the Remedial Design/Construction Work Plans for the ICDF landfill and evaporation pond and the Staging, Storage, Sizing, and Treatment Facility. Each of the major facilities or systems is described including the design criteria.

J. Simonds

2006-09-01T23:59:59.000Z

140

Status Update for Implementing Best Available Technology per DOE Order 5400.5 (2003)  

SciTech Connect (OSTI)

This report identifies discharges of liquid waste streams that require documentation of the best available technology selection process at Bechtel BWXT Idaho, LLC, operated facilities at the Idaho National Engineering and Environmental Laboratory. The best available technology selection process is conducted according to Department of Energy Order 5400.5, Chapter II (3), Management and Control of Radioactive Materials in Liquid Discharges and Phaseout of Soil Columns and Department of Energy guidance. This report evaluates only those liquid waste streams and facilities where the best available technology selection process was determined to apply. Two facilities (Idaho Nuclear Technology and Engineering Center New Percolation Ponds and Test Area North/Technical Support Facility Sewage Treatment Plant Disposal Pond) at the Idaho National Engineering and Environmental Laboratory required documentation of the best available technology selection process. These two facilities required documentation of the best available technology selection process because they discharge wastewater that may contain process-derived radionuclides to a soil column even though the average radioactivity levels are typically below drinking water maximum contaminant levels. At the request of the Department of Energy Idaho Operations Office, the 73.5-acre Central Facilities Area Sewage Treatment Plant land application site is included in this report to ensure the requirements of DOE Order 5400.5, Chapter II, Section 3 are met. The Central Facilities Area Sewage Treatment Plant effluent contains process-derived radionuclides from radioactive tracers used in certain analytical procedures. The radioactivity levels of these radionuclides are below maximum contaminant levels. The Department of Energy Idaho Operations Office will submit this report to their field office manager for approval according to DOE Order 5400.5, Chapter II, Section 3.b.(1).

Michael Lewis

2004-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

DOE Order Self Study Modules - DOE O 458.1, Radiation Protection of the Public and the Environment  

Broader source: Energy.gov (indexed) [DOE]

58.1 58.1 RADIATION PROTECTION OF THE PUBLIC AND THE ENVIRONMENT DOE O 458.1 Familiar Level August 2011 1 DOE O 458.1 RADIATION PROTECTION OF THE PUBLIC AND THE ENVIRONMENT FAMILIAR LEVEL OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to answer the following questions: 1. What are the objectives of DOE O 458.1? 2. What are the definitions for the following terms?  Residual radioactive material  Public dose  ALARA  Soil column ( in the context of radiation protection of the environment) 3. What are three basic considerations that should be observed in an ALARA process for DOE radioactive activities? 4. What are four elements that must be included in dose evaluations to demonstrate

142

Order Module--DOE G 450.4-1B, INTEGRATED SAFETY MANAGEMENT SYSTEM GUIDE  

Broader source: Energy.gov [DOE]

This Guide has two purposes. One purpose is to assist DOE contractors in developing, describing, and implementing an ISMS to comply with DOE P 450.4, Safety Management system Policy; DOE P 450.5,...

143

Enforcement Cases | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Enforcement Cases Enforcement Cases Enforcement Cases RSS December 20, 2013 AeroSys: Order (2011-SCE-1624) DOE ordered AeroSys, Inc. (AeroSys) to pay a $100,000 civil penalty after finding AeroSys had (1) failed to certify that certain models of space-constrained central air conditioners and air conditioning heat pumps comply with the applicable energy conservation standards; and (2) manufactured and distributed in commerce in the U.S. units of noncompliant models of space-constrained central air conditioners and air conditioning heat pumps. November 15, 2013 Sylvane: Order (2013-CE-36005) DOE ordered Sylvane, Inc. to pay a $4,000 civil penalty after finding Sylvane had failed to certify that certain models of dehumidifiers comply with the applicable energy conservation standards.

144

ORDER  

Broader source: Energy.gov (indexed) [DOE]

PP&L EnergyPlus Company PP&L EnergyPlus Company Order No. EA-210 I. BACKGROUND Exports of electricity from the United States to a foreign country are regulated and require authorization under section 202(e) of the Federal Power Act (FPA) (16 U.S.C. §824a(e)). On May 4, 1999, PP&L EnergyPlus Company (PP&L EnergyPlus) applied to the Office of Fossil Energy (FE) of the Department of Energy (DOE) for authorization to transmit electric energy to Canada as a power marketer. PP&L EnergyPlus, a limited liability company based in Pennsylvania, does not own or control any electric generating or transmission facilities, nor does it have a franchised service area. PP&L EnergyPlus proposes to purchase surplus electric energy from electric utilities and other suppliers within the United States and to export this energy on its own behalf to Canada.

145

DOE Order Self Study Modules - DOE O 425.1D, Verification of Readiness to Startup or Restart Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

5.1D 5.1D VERIFICATION OF READINESS TO START UP OR RESTART NUCLEAR FACILITIES DOE O 425.1D Familiar Level June 2011 1 DOE O 425.1D VERIFICATION OF READINESS TO START UP OR RESTART NUCLEAR FACILITIES FAMILIAR LEVEL _________________________________________________________________________ OBJECTIVES Given the familiar level of this module and the resources, you will be able to perform the following: 1. What is the purpose of DOE O 425.1D, Verification of Readiness to Startup or Restart Nuclear Facilities? 2. What are the requirements for determining the level of readiness review [operational readiness reviews (ORRs) and readiness assessments (RAs)]? 3. What are the requirements for determining the startup authorization authority? 4. What are the requirements for startup notification reports?

146

Status Update for Implementing Best Available Technology per DOE Order 5400.5  

SciTech Connect (OSTI)

This report identifies discharges of liquid waste streams that require documentation of the best available technology selection process at Bechtel BWXT Idaho, LLC, operated facilities at the Idaho National Engineering and Environmental Laboratory. The best available technology selection process is conducted according to Department of Energy Order 5400.5, Chapter II (3), ''Management and Control of Radioactive Materials in Liquid Discharges and Phaseout of Soil Columns'' and Department of Energy guidance. This report evaluates only those liquid waste streams and facilities where the best available technology selection process was determined to be applicable. In addition, the Department of Energy Idaho Operations Office will submit this report to their field office manager for approval according to DOE Order 5400.5, Chapter II, Section 3.b.(1). According to Department of Energy guidance, ''If the liquid waste stream is below maximum contaminant levels, then the goals of the best available technology selection process are being met and the liquid waste stream is considered 'clean water.' However, it is necessary to document this through the best available technology selection process.'' Because liquid waste streams below drinking water maximum contaminant levels are already considered ''clean water,'' additional treatment technologies are considered unnecessary and unjustifiable on a cost-benefit basis and are not addressed in this report. Two facilities (Idaho Nuclear Technology and Engineering Center New Percolation Ponds and Test Area North/Technical Support Facility Disposal Pond) at the Idaho National Engineering and Environmental Laboratory required documentation of the best available technology selection process (Section 4). These two facilities required documentation of the best available technology selection process because they discharge wastewater that may contain process-derived radionuclides to a soil column even though the average radioactivity levels are typically below drinking water maximum contaminant levels. At the request of the Department of Energy Idaho Operations Office, the 73.5-acre Central Facilities Area Sewage Treatment Plant land application site is included in Section 4 of this report to ensure the requirements of DOE Order 5400.5, Chapter II, Section 3 are met. The Central Facilities Area Sewage Treatment Plant effluent contains process-derived radionuclides from radioactive tracers used in certain analytical procedures. The radioactivity levels of these radionuclides are below maximum contaminant levels.

Michael G. Lewis

2003-09-01T23:59:59.000Z

147

Status Update for Implementing Best Available Technology per DOE Order 5400.5 - September 2002  

SciTech Connect (OSTI)

This report identifies discharges of liquid waste streams that require documentation of the Best Available Technology selection process at Bechtel BWXT Idaho, LLC, operated facilities at the Idaho National Engineering and Environmental Laboratory. The Best Available Technology selection process is conducted according to Department of Energy Order 5400.5, Chapter II (3),Management and Control of Radioactive Materials in Liquid Discharges and Phaseout of Soil Columns and Department of Energy guidance. Only those liquid waste streams and facilities requiring the Best Available Technology selection process are evaluated in further detail. In addition, this report will be submitted to the Department of Energy Idaho Operations Office Field Office manager for approval according to DOE Order 5400.5, Chapter II, Section 3.b.(1). Two facilities (Idaho Nuclear Technology and Engineering Center existing Percolation Ponds and Test Area North/Technical Support Facility Disposal Pond) at the Idaho National Engineering and Environmental Laboratory required documentation of the Best Available Technology selection process (Section 4). These two facilities required documentation of the Best Available Technology selection process because they discharge wastewater that may contain process-derived radionuclides to a soil column even though the average radioactivity levels are typically below drinking water maximum contaminant levels. At the request of the Department of Energy Idaho Operations Office, the 73.5-acre Central Facilities Area Sewage Treatment Plant land application site is included in Section 4 of this report to ensure the requirements of DOE Order 5400.5, Chapter II, Section 3 are met. The Central Facilities Area Sewage Treatment Plant effluent contains process-derived radionuclides from radioactive tracers used in certain analytical procedures. The radioactivity levels of these radionuclides are below maximum contaminant levels. According to Department of Energy guidance, If the liquid waste stream is below maximum contaminant levels, then the goals of the Best Available Technology selection process are being met and the liquid waste stream is considered clean water. However, it is necessary to document this through the Best Available Technology selection process. Because liquid waste streams below maximum contaminant levels are already considered clean water, additional treatment technologies are considered unnecessary and are not addressed in this report.

Lewis, Michael George

2002-09-01T23:59:59.000Z

148

Report on inspection of compliance with DOE Order 2030.4B at the Savannah River Site  

SciTech Connect (OSTI)

The purpose of this inspection was to evaluate contractor compliance at the Savannah River Site (SRS) with Department of Energy (DOE) Order 2030.4B, {open_quotes}Reporting Fraud, Waste, And Abuse To The Office Of Inspector General.{close_quotes} The specific objective was to determine if the SRS management and operating (M&O) contractors were complying with the requirements in Paragraph 6.c. of DOE Order 2030.4B. These requirements are: (1) annual notification to employees of their duty to report allegations of fraud, waste, abuse, corruption, or mismanagement; (2) display and publish the DOE Office of Inspector General (OIG) Hotline telephone number in common areas of buildings; (3) display and publish the DOE OIG Hotline number in telephone books and newsletters; and (4) notify the OIG cases referred to other law enforcement entities.

NONE

1997-03-01T23:59:59.000Z

149

DOE Order 442.1 A: Department of Energy Employee Concerns Program...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

referred to other offices or programs and tracked by the ECP until they are resolved (referral of a concern); (c) transferred to another DOE or contractor organization with...

150

Designation Order 00-01.00A to Susan F. Beard - DOE Directives...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Susan F. Beard is hereby designated the Department of Energy's (DOE) Designated Agency Ethics Official, as that title and its responsibilities are described in 5 CFR Part 2638,...

151

Order Module--DOE O 414.1D, QUALITY ASSURANCE  

Broader source: Energy.gov [DOE]

"To ensure that DOE, including NNSA, products and services meet or exceed customers requirements and expectations.To achieve quality for all work based upon the following principles:

152

All General Counsel Reports | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

2, 2010 2, 2010 NBP RFI: Communications Requirements- Comments of Avista Corporation Comments of Avista Corporation on Implementing the National Broadband Plan by Studying the Communications Requirements of Electric Utilities to Inform Federal Smart Grid Policy July 1, 2010 AeroSys: Order (2010-CE-01/0201 and 2010-SE-0302) DOE ordered AeroSys, Inc. to pay a $25,000 civil penalty after finding AeroSys had manufactured and distributed in commerce in the U.S. various models of air conditioners and air conditioning heat pumps that did not comport with the applicable energy conservation standards. In addition, AeroSys had distributed air conditioners and air conditioning heat pumps without submitting the required certification reports. June 30, 2010 Class Patent Waiver W(C)2010-007

153

All General Counsel Reports | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

All General Counsel Reports All General Counsel Reports All General Counsel Reports RSS January 9, 2014 DETERMINATION OF EXCEPTIONAL CIRCUMSTANCES UNDER THE BAYH-DOLE ACT FOR ENERGY EFFICIENCY, RENEWABLE ENERGY, AND ADVANCED ENERGY TECHNOLOGIES Under the Bayh-Dole Act, 35 U.S.C. §§ 200-12 ("Bayh-Dole"), Federal agencies may determine that "exceptional circumstances" exist such that a modification in the patent rights disposition provided under the Act would better promote its objectives. December 20, 2013 AeroSys: Order (2011-SCE-1624) DOE ordered AeroSys, Inc. (AeroSys) to pay a $100,000 civil penalty after finding AeroSys had (1) failed to certify that certain models of space-constrained central air conditioners and air conditioning heat pumps comply with the applicable energy conservation standards; and (2)

154

ORDER  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

6-2010 6-2010 PACKAGING AND TRANSPORTATION FOR OFFSITE SHIPMENT OF MATERIALS OF NATIONAL SECURITY INTEREST NATIONAL NUCLEAR SECURITY ADMINISTRATION Office of Defense Programs DOE O 461.1B DOE O 461.1B 1 12-16-2010 PACKAGING AND TRANSPORTATION FOR OFFSITE SHIPMENT OF MATERIALS OF NATIONAL SECURITY INTEREST 1. PURPOSE. The Department of Energy (DOE) has broad authority under the Atomic Energy Act of 1954, as amended (AEA), to regulate all aspects of activities involving radioactive materials that are undertaken by DOE or on its behalf, including the transportation of radioactive materials. DOE exercises this authority to regulate certain DOE shipments, such as shipments of materials of national security interest undertaken by governmental employees or shipments involving special circumstances. The National

155

DOE Order 458.1 Property Clearance Requirements and Factors Considered...  

Office of Environmental Management (EM)

contained in DOE O 458.1, including the methods to release or clear property: process knowledge and authorized limits. In addition, it will provide a special focus on the efforts...

156

Order Module--DOE O 430.1B, REAL PROPERTY ASSET MANAGEMENT  

Broader source: Energy.gov [DOE]

"The objective of DOE O 430.1B, Real Property Asset Management, is to establish a corporate, holistic, and performance-based approach to real property life-cycle asset management that links real...

157

Policy Flash 2014-30 DOE Order 412.1a, Work Authorization System Administrative Change  

Broader source: Energy.gov [DOE]

Questions concerning this policy flash should be directed to Mike Dombrowski, of the Office of Acquisition and Project Management Policy at 202-287-1828 or at michael.dombrowski@hq.doe.gov.

158

Order Module--DOE O 420.1B, FACILITY SAFETY  

Broader source: Energy.gov [DOE]

To ensure that new DOE hazard category 1, 2, and 3 nuclear facilities are designed and constructed in a manner that ensures adequate protection to the public, workers, and the environment from...

159

Guidance document for revision of DOE Order 5820.2A, Radioactive Waste Technical Support Program. Revision 1  

SciTech Connect (OSTI)

This document provides guidance for the revision of DOE Order 5820.2A, ``Radioactive Waste Management.`` Technical Working Groups have been established and are responsible for writing the revised order. The Technical Working Groups will use this document as a reference for polices and procedures that have been established for the revision process. The overall intent of this guidance is to outline how the order will be revised and how the revision process will be managed. In addition, this document outlines technical issues considered for inclusion by a Department of Energy Steering Committee.

Kudera, D.E.; McMurtrey, C.D.; Meagher, B.G.

1993-04-01T23:59:59.000Z

160

Does  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Does Does the cellulose-binding module move on the cellulose surface? Yu-San Liu Æ Yining Zeng Æ Yonghua Luo Æ Qi Xu Æ Michael E. Himmel Æ Steve J. Smith Æ Shi-You Ding Received: 26 November 2008 / Accepted: 11 May 2009 / Published online: 19 June 2009 Ó Springer Science+Business Media B.V. 2009 Abstract Exoglucanases are key enzymes required for the efficient hydrolysis of crystalline cellulose. It has been proposed that exoglucanases hydrolyze cellulose chains in a processive manner to produce primarily cellobiose. Usually, two functional modules are involved in the processive mechanism: a catalytic module and a carbohydrate-binding module (CBM). In this report, single molecule tracking techniques were used to analyze the molecular motion of CBMs labeled with quantum dots (QDs) and bound to cellulose crystals. By tracking the single QD, we observed that the family 2 CBM from

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Pending Long-Term Applications to Export LNG to Non-FTA Countries - Listed in Order DOE Will Commence Processing  

Broader source: Energy.gov (indexed) [DOE]

Long-Term Applications to Export LNG to Non-FTA Countries - Listed in Order DOE Will Commence Processing Long-Term Applications to Export LNG to Non-FTA Countries - Listed in Order DOE Will Commence Processing Order to Be Processed Company DOE/FE Docket No. Date DOE Application Filed FERC Pre-Filing Docket No. Date Applicant Received FERC Approval to Begin Pre-Filing Process 1 Freeport LNG Expansion, L.P. and FLNG Liquefaction, LLC 10-161-LNG 12/17/2010 PF11-2 1/5/2011 2 Lake Charles Exports, LLC 11-59-LNG 5/6/2011 PF12-8 4/6/2012 3 Dominion Cove Point LNG, LP 11-128-LNG 10/3/2011 PF12-16 6/26/2012 4 Freeport LNG Expansion, L.P. and FLNG Liquefaction, LLC 11-161-LNG 12/19/2011 PF11-2 1/5/2011 5 Cameron LNG, LLC 11-162-LNG 12/21/2011 PF12-13 5/9/2012 6 Jordan Cove Energy Project, L.P. 12-32-LNG 3/23/2012 PF12-7 3/6/2012 7 LNG Development Company, LLC (d/b/a Oregon LNG) 12-77-LNG 7/16/2012 PF12-18

162

DOE  

Gasoline and Diesel Fuel Update (EIA)

DOE DOE /E/A- 0202( 83//Q J Sh or t-T er m En er gy O ut lo ok a to m Quar terly Proje ction s Febru ary 1983 Ene rgy Info rma tion Adm inist ratio n Was hing ton, D.C. t rt jrt .or t lor t lor t .lor t- ior t- ior t <.o rt ort . m .er m -Te rm -Te rm -Te rm -Te rm -Te rm -Te rm -Te rm -Te rm -Te rm -Te rm -Te rm -Te rm -T erm -T erm -T erm Nrm ue rgy En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y En erg y ^n erg y Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Ou tlo ok Sh ort -T erm 1 Sh ort -T erm Sh ort -T erm Sh ort -T erm Sh ort -T erm Sh ort -T erm Sh ort -T erm Sh ort -T erm Sh ort -T erm Sh ort -T erm Sh ort -T erm Sh ort -T erm

163

DOE Awards Task Order for Disposal of Los Alamos National Laboratory...  

Energy Savers [EERE]

DeliveryIndefinite Quantity (IDIQ) Master Contract. The award is a firm, fixed-price task order, based on pre-established rates with a 1.29 million value and has a...

164

DOE Celebrates 20-Year Anniversary of Executive Order 12898 on Environmental Justice  

Broader source: Energy.gov [DOE]

February 11, 2014, marked the 20-year anniversary of Executive Order (EO) 12898, Federal Actions To Address Environmental Justice in Minority Populations and Low-Income Populations. EO 12898...

165

Order Module--DOE O 458.1, RADIATION PROTECTION OF THE PUBLIC AND THE ENVIRONMENT  

Broader source: Energy.gov [DOE]

The familiar level of this module is divided into two sections. In the first section, we will discuss the objectives and definitions related to the Order. In the second section, we will discuss the...

166

ORDER  

Office of Legacy Management (LM)

Act Restricted Data (RD), Formerly Restricted Data (FRD), and Transclassified Foreign Nuclear Information (TFNI) or Executive Order (E.O.) 13526 National Security Information...

167

Microsoft Word - Comments on Alexandria Mirant Plant-DOE order to re-open-final.doc  

Broader source: Energy.gov (indexed) [DOE]

P.O. Box 11138 Takoma Park, MD 20912 P.O. Box 11138 Takoma Park, MD 20912 (301) 891-6726 info@chesapeakeclimate.org March 22, 2006 Mr. Lawrence Mansueti Permitting, Siting, and Analysis Division Office of Electricity Delivery and Energy Reliability Department of Energy 1000 Independence Avenue, SW Washington, DC 20585-0119 Re: Comments on Emergency Order to Resume Limited Operation at the Potomac River Generating Station, Alexandria, VA. Dear Mr. Mansueti, This letter is in response to the Department of Energy Emergency Order ("Emergency Order") to Resume Limited Operation at the Potomac River Generating Station, Alexandria, VA, in response to electricity reliability concerns in Washington, DC. The Chesapeake Climate Action Network (CCAN) is the first regional, non-profit organization to work solely on decreasing the

168

BEFORE THE U.S. DEPARTMENT OF ENERGY WASHINGTON, D.C.  

Broader source: Energy.gov (indexed) [DOE]

AeroSys, Inc., AeroSys, Inc., Case Number: 2010-CE-01 /0201 and 2010-SE-0302 Respondent ORDER By the General Counsel, U.S. Department of Energy: 1. In this Order, I adopt the attached Compromise Agreement entered into between the U.S. Department of Energy ("DOE") and AeroSys, Inc. ("Respondent"). The Compromise Agreement resolves two cases. DOE case number 2010-CE-01 /0201 pursued a civil penalty for violations of the compliance certification requirements at 10 C.F.R. § 430.62. In DOE case number 2010-SE-0302, DOE determined that Respondent had distributed in commerce in the United States central air conditioners and central air conditioning heat pumps that did not meet the applicable minimum efficiency standards found at 10 C.F.R. § 430.32 2. The DOE and Respondent have negotiated the terms of the Compromise

169

DOE Order Self Study Modules - DOE HDBK 1203, 1204, 1205, 1206: Guides to Good Practices for Training, Tests, and On-the-Job Training  

Broader source: Energy.gov (indexed) [DOE]

HDBK-1203-97 HDBK-1203-97 GUIDE TO GOOD PRACTICES FOR TRAINING OF TECHNICAL STAFF AND MANAGERS DOE-HDBK-1204-97 GUIDE TO GOOD PRACTICES FOR THE DEVELOPMENT OF TEST ITEMS DOE-HDBK-1205-97 GUIDE TO GOOD PRACTICES FOR THE DESIGN, DEVELOPMENT, AND IMPLEMENTATION OF EXAMINATIONS DOE-HDBK-1206-98 GUIDE TO GOOD PRACTICES FOR ON-THE-JOB TRAINING DOE-HDBK-1203-97, 1204-97, 1205-97, and 1206-98 Familiar Level August 2011 1 DOE-HDBK-1203-97, GUIDE TO GOOD PRACTICES FOR TRAINING OF TECHNICAL STAFF AND MANAGERS; DOE-HDBK-1204-97, GUIDE TO GOOD PRACTICES FOR THE DEVELOPMENT OF TEST ITEMS; DOE-HDBK-1205-97, GUIDE TO GOOD PRACTICES FOR THE DESIGN, DEVELOPMENT, AND IMPLEMENTATION OF EXAMINATIONS; AND DOE-HDBK-1206-98, GUIDE TO GOOD PRACTICES FOR ON-THE-JOB TRAINING FAMILIAR LEVEL

170

Order Module--DOE O 460.1C, PACKAGING AND TRANSPORTATION SAFETY, DOE O 460.2A, DEPARTMENTAL MATERIALS TRANSPORTATION AND PACKAGING MANAGEMENT  

Broader source: Energy.gov [DOE]

"The familiar level of this module is divided into two sections. The objectives and requirements of DOE O 460.1C and DOE O 460.2A will be discussed in the first and second sections, respectively....

171

Energy Economy | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

April 1, 2010 April 1, 2010 Wisconsin LED Plant Benefits from Recovery Act "It's a win for everyone: the environment, the cities, buildings, for us," says Gianna O'Keefe, marketing manager for Ruud Lighting, which is producing LED lights that emit more light, have a longer life and provide anywhere from 50 to 70 percent in energy savings. March 30, 2010 DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Today, the Department of Energy announced that it is requiring AeroSys, Inc. to stop distributing two product models - one air conditioner and one heat pump - that DOE testing found to consume more energy than allowed under federal efficiency standards. This is the latest step in the Department's investigation into whether AeroSys has been selling products

172

DOE Order Self Study Modules - DOE-STD-3009-94, Preparation Guide for U.S. Department of Energy Nonreactor Nuclear Facilities Documented Safety Analyses  

Broader source: Energy.gov (indexed) [DOE]

3009-94 3009-94 PREPARATION GUIDE FOR U.S. DEPARTMENT OF ENERGY NONREACTOR NUCLEAR FACILITY DOCUMENTED SAFETY ANALYSES DOE-STD-3009-94 Familiar Level June 2011 1 DOE-STD-3009-94 PREPARATION GUIDE FOR U.S. DEPARTMENT OF ENERGY NONREACTOR NUCLEAR FACILITY DOCUMENTED SAFETY ANALYSES FAMILIAR LEVEL _______________________________________________________________________________ OBJECTIVES Given the familiar level of this module and the resources listed below, you will be able to answer the following questions: 1. What are five general requirements for contractors who are responsible for a hazard category 1, 2, or 3 nuclear facility, as related to establishing a safety basis? 2. What actions must a contractor take when it is made aware of a potential inadequacy of

173

Page not found | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

51 - 3360 of 26,777 results. 51 - 3360 of 26,777 results. Download Tennessee Recovery Act State Memo http://energy.gov/downloads/tennessee-recovery-act-state-memo Download CX-001544: Categorical Exclusion Determination Recovery Act: Demonstrating the Commercial Feasibility of Geopressured-Geothermal Power Development at the Sweet Lake Field, Cameron Parish, Louisiana CX(s) Applied: B3.1, A9 Date: 04/01/2010 Location(s): Cameron Parish, Louisiana Office(s): Energy Efficiency and Renewable Energy, Golden Field Office http://energy.gov/nepa/downloads/cx-001544-categorical-exclusion-determination Download AeroSys: Order (2010-CE-01/0201 and 2010-SE-0302) DOE ordered AeroSys, Inc. to pay a $25,000 civil penalty after finding AeroSys had manufactured and distributed in commerce in the U.S. various

174

Report on Inspection of Compliance With DOE Order 2030.4B at the Savannah River Site, INS-9702  

Broader source: Energy.gov (indexed) [DOE]

Department of Energy Headquarters Gopher Department of Energy Headquarters Gopher gopher,hr.doe.gov Depart of Energy Headquarters Anonymous FTP vm 1.hqadmin.doe.gov U.S. Department of Energy Human Resources and Administration Home Page http://www.hr.doe.gov/ig Your comments would be appreciated and can be provided on the Customer Response Form attached to the report. This report can be obtained from the U.S. Department of Energy Office of Scientific and Technical Information P.O. Box 62 Oak Ridge, Tennessee 37831

175

Order Module--DOE O 425.1D, VERIFICATION OF READINESS TO START UP OR RESTART NUCLEAR FACILITIES  

Broader source: Energy.gov [DOE]

"The familiar level of this module is divided into three sections. In the first section we will discuss the purpose of DOE O 425.1D and the requirements for 1) determining the level of readiness...

176

"Order Module--DOE-STD-3009-94, PREPARATION GUIDE FOR U.S. DEPARTMENT OF ENERGY NONREACTOR NUCLEAR FACILITY  

Broader source: Energy.gov [DOE]

"The familiar level of this module is divided into three sections. The first section is an introduction to DOE-STD-3009-94. In the second section, we will introduce the 17 chapters of a documented...

177

Review of the Pantex Site Office's Compliance with DOE Order 425.1D, Verification of Readiness to Start Up or Restart Nuclear Facilities, June 2012  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Pantex Site Office's Compliance with Pantex Site Office's Compliance with DOE Order 425.1D, Verification of Readiness to Start Up or Restart Nuclear Facilities June 2012 Office of Safety and Emergency Management Evaluations Office of Enforcement and Oversight Office of Health, Safety and Security U.S. Department of Energy i Table of Contents 1 1.0 Purpose .................................................................................................................................................. 1 2.0 Introduction ........................................................................................................................................... 1 3.0 Assessment Methodologies and Approach ........................................................................................... 1

178

Review of the Pantex Site Office's Compliance with DOE Order 425.1D, Verification of Readiness to Start Up or Restart Nuclear Facilities, June 2012  

Broader source: Energy.gov (indexed) [DOE]

Pantex Site Office's Compliance with Pantex Site Office's Compliance with DOE Order 425.1D, Verification of Readiness to Start Up or Restart Nuclear Facilities June 2012 Office of Safety and Emergency Management Evaluations Office of Enforcement and Oversight Office of Health, Safety and Security U.S. Department of Energy i Table of Contents 1 1.0 Purpose .................................................................................................................................................. 1 2.0 Introduction ........................................................................................................................................... 1 3.0 Assessment Methodologies and Approach ........................................................................................... 1

179

DOE-FLEX: DOE's Telework Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The order establishes the requirements and responsibilities for the Departments telework program. Cancels DOE N 314.1.

2013-02-11T23:59:59.000Z

180

DOE Order 350.3  

Broader source: Energy.gov [DOE]

LABOR STANDARDS COMPLIANCE, CONTRACTOR LABOR RELATIONS, AND CONTRACTOR WORKFORCE RESTRUCTURING PROGRAMS

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Order Module--SAFETY SOFTWARE GUIDE FOR USE WITH 10 CFR 830, SUBPART A, QUALITY ASSURANCE REQUIREMENTS, AND DOE O 414.1C, QUALITY ASSURANCE  

Broader source: Energy.gov [DOE]

According to DOE-STD-1146-2007, General Technical Base Qualification Standard, this module was to summarize the quality assurance information found in attachments 3, 4, and 5, of DOE O 414.1C,...

182

DOE HANDBOOK  

Broader source: Energy.gov (indexed) [DOE]

Handbook on Overseas Assignments Handbook on Overseas Assignments United States Department of Energy Office of Human Capital Management July 2013 2 Introduction This handbook covers all types of Federal employment overseas, including details, both within DOE as well as to other agencies; transfers to approved international organizations; assignments to permanent DOE positions; cost-free experts; and personal services agreements (PSAs). This handbook contains information, guidance, sample service agreements, and related documentation that are to be used to implement the following directives: a. Executive Order 11552, Providing for Details and Transfers of Federal Employees to International Organizations at http://www.archives.gov/federal-register/codification/executive-order/11552.html;

183

Order Module--DOE-STD-1104-2009, REVIEW AND APPROVAL OF NUCLEAR FACILITY SAFETY BASIS AND SAFETY DESIGN BASIS DOCUMENTS  

Broader source: Energy.gov [DOE]

The familiar level of this module is divided into two sections that are intended to provide only an overview of the material contained in DOE-STD-1104-2009, which should be consulted for complete...

184

DOE G 414  

Energy Savers [EERE]

Policy, Order, Notice, or Manual. U.S. DEPARTMENT OF ENERGY Washington, D.C. NOT MEASUREMENT SENSITIVE DOE G 414.1-4 i (and ii) 6-17-05 FOREWORD This Department of Energy (DOE)...

185

DOE/ID-Number  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

work order DOE Department of Energy EMC electromagnetic compatibility EMI electromagnetic interference EPRI Electric Power Research Institute eWP electronic work package HVAC...

186

DOE/ID-Number  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

procedures CBWO computer-based work order CCV correct component verification CNS Catawba Nuclear Station DOE Department of Energy HVAC heating, venting, and air conditioning I&C...

187

DOE Corporate Operating Experience Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order institutes a DOE wide program for the management of operating experience to prevent adverse operating incidents and facilitate the sharing of good work practices among DOE sites. Cancels DOE O 210.2.

2011-04-08T23:59:59.000Z

188

Summary of the Special Analysis of Savannah River Depleted Uranium Trioxide Demonstrating the Before and After Impacts on the DOE Order 435.1 Performance Objective and the Peak Dose  

SciTech Connect (OSTI)

This report summarizes the special analysis (SA) of the Savannah River Depleted Uranium Trioxide waste stream (SVRSURANIUM03, Revision 1) demonstrating the before and after impacts of the waste stream to the DOE Order 435.1 performance objective at the disposal facility, and the peak dose. The Nevada Division of Environmental Protection (NDEP) requested this SA and asked the Nevada Site Office (NSO) to run the SA deterministically and assume that all the model conditions remain the same regardless of the length of time to the peak dose. Although the NDEP accepts that DOE Order 435.1 requires a compliance period of 1,000 years, it also requested to know what year, if any, the specific DOE performance objectives will be exceeded. Given the NDEPs requested model conditions, the SA demonstrates the Rn-222 peak dose will occur in about 2 million years and will exceed the performance objective in about 6,000 years. The 0.25 mSv y-1 all-pathway performance objective was not exceeded for the resident scenario after reaching the 4 million year peak dose.

Shott, G.J.

2011-01-15T23:59:59.000Z

189

DOE Policies | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

DOE Policies DOE Policies DOE Policies Cyber Security DOE O 205.1B Department of Energy Cyber Security Management (Approved May 16, 2011) Information Management Planning DOE Guide to IT Capital Planning and Investment, September 2010 (pdf) DOE IRM Strategic Plan, FY 2009 - 2011 (pdf) DOE N 203.1, Software Quality Assurance (pdf) DOE G 242.1-1, Forms Management Guide (pdf) DOE O 203.1 Limited Personal Use of Government Office Equipment Including Information Technology (pdf) Information Management Program Order, DOE O 200.1A (pdf) (Access to this document is restricted to DOE employees only) Records Management DOE Directive, O 243.1, Records Management Program (pdf) DOE Directive, O 243.2, Vital Records (pdf) DOE Directive, O 200.2, Information Collection Management Program

190

DECISION AND ORDER  

Broader source: Energy.gov (indexed) [DOE]

, 2004 , 2004 DECISION AND ORDER OF THE DEPARTMENT OF ENERGY Decision of the Director Name of Petitioner: Charles L. Evans Date of Filing: May 17, 2004 Case Number: TBU-0026 Charles Evans, a former employee of Fluor Hanford Inc. (Fluor), a Department of Energy (DOE) contractor, appeals the DOE Richland Operations Office=s (Richland) dismissal of the whistleblower complaint he filed against Fluor under 10 C.F.R. Part 708, the DOE Contractor Employee Protection Program. I. BACKGROUND A. The DOE=s Contractor Employee Protection Program The DOE=s Contractor Employee Protection Program was established to safeguard Apublic and employee health and safety; ensur[e] compliance with applicable laws, rules, and regulations; and prevent[] fraud, mismanagement, waste and abuse@ at DOE=s government-owned, contractor-operated facilities. 57 Fed. Reg.

191

DOE O 420 Briefing Slides  

Broader source: Energy.gov (indexed) [DOE]

Order (O) 420.1C Order (O) 420.1C Facility Safety Changes to DOE O 420 1C and Changes to DOE O 420.1C and Expectations for Effective Implementation Pranab Guha, HS-31 Office of Nuclear Safety Basis & Facility Design February y 2013 1 Objectives Objectives  Obtain feedback and/or address issues or concerns concerns  Understand the history of DOE O 420.1  Understand the drivers for changes in DOE O Understand the drivers for changes in DOE O 420.1C  Understand the major differences between Understand the major differences between DOE O 420.1B and DOE O 420.1C  Understand DOE exp pectation for effective implementation 2 History of DOE Order 420 1 History of DOE Order 420.1  DOE Order 420.1 issued in October 1995 and combined the following DOE Orders:  DOE Order 6430.1A, General Design Criteria

192

DOE Corporate Operating Experience Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order establishes a DOE wide program for management of operating experience to prevent adverse operating incidents and to expand the sharing of good work practices among DOE sites. Canceled by DOE O 210.2A. Does not cancel other directives.

2006-06-12T23:59:59.000Z

193

Order Module--DOE-HDBK-1203-97, GUIDE TO GOOD PRACTICES FOR TRAINING OF TECHNICAL STAFF AND MANAGERS, DOE-HDBK-1204-97, GUIDE TO GOOD PRACTICES FOR THE DEVELOPMENT OF TEST ITEMS,DOE-HDBK-1205-97, GUIDE TO GOOD PRACTICES FOR THE DESIGN, DEVELOPMENT  

Broader source: Energy.gov [DOE]

The familiar level of this module is divided into four sections. In the first section, the module will present DOE-HDBK-1203-97, Training Program for Technical Staff Personnel, which covers the...

194

Technical Standards,DOE Standards and Corresponding Directives...  

Energy Savers [EERE]

More Documents & Publications Technical Standards, DOE Orders and Applicable CFRsDEAR Crosswalk - February 2, 2002 DOE-STD-1037-93 All Active DOE Technical Standards Document...

195

CRADA Order Revision  

Broader source: Energy.gov (indexed) [DOE]

CRADA Order Revision CRADA Order Revision Linda Field Patent Counsel Department of Energy Goal CRADA Order DOE O 483.1 CRADA Manual DOE M 483.1-1 CRADA Order DOE O XXXX.X Departmental Directive Program Types of Directives Policies Regulations Orders Notices Manuals Guides Technical Standards Departmental Directive Program Directives Life Cycle Development Coordination Implementation Review (Certification) Development Phase *Orders are uploaded to RevCom for review and comment by all affected parties *60 days to develop draft & submit to MA-90 *Solicits input from stakeholders ( incl. field, contractors, and/or program counsel) Coordination Phase *MA-90 parses directive & sets due dates for review & comment *HQ Directives Points of Contact (DPCs) *Have 45 days to submit official comments on behalf of their

196

DOE Cooperative Research and Development Agreements  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The order establishes policy, requirements, and responsibilities for the oversight, management, and administration of Cooperative Research and Development Agreement (CRADA) activities at DOE facilities. Cancels DOE O 483.1 Admin Chg 1 and DOE M 483.1-1.

2013-11-06T23:59:59.000Z

197

DOE G 414  

Broader source: Energy.gov (indexed) [DOE]

INITIATED BY: INITIATED BY: http://www.directives.doe.gov Office of Environment, Safety and Health DOE G 414.1-4 Approved 6-17-05 Certified 11-3-10 SAFETY SOFTWARE GUIDE for USE with 10 CFR 830 Subpart A, Quality Assurance Requirements, and DOE O 414.1C, Quality Assurance [This Guide describes suggested nonmandatory approaches for meeting requirements. Guides are not requirements documents and are not construed as requirements in any audit or appraisal for compliance with the parent Policy, Order, Notice, or Manual.] U.S. DEPARTMENT OF ENERGY Washington, D.C. NOT MEASUREMENT SENSITIVE DOE G 414.1-4 i (and ii) 6-17-05 FOREWORD This Department of Energy (DOE) Guide is approved by the Office of Environment, Safety and Health and is available for use by all DOE and National Nuclear Security Administration

198

DOE G 414  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

http://www.directives.doe.gov Office of Environment, Safety and Health DOE G 414.1-4 Approved 6-17-05 Certified 11-3-10 SAFETY SOFTWARE GUIDE for USE with 10 CFR 830 Subpart A, Quality Assurance Requirements, and DOE O 414.1C, Quality Assurance [This Guide describes suggested nonmandatory approaches for meeting requirements. Guides are not requirements documents and are not construed as requirements in any audit or appraisal for compliance with the parent Policy, Order, Notice, or Manual.] U.S. DEPARTMENT OF ENERGY Washington, D.C. NOT MEASUREMENT SENSITIVE DOE G 414.1-4 i (and ii) 6-17-05 FOREWORD This Department of Energy (DOE) Guide is approved by the Office of Environment, Safety and Health and is available for use by all DOE and National Nuclear Security Administration

199

Administrative Compliance Order HWB-14-21 Waste Isolation Pilot...  

Office of Environmental Management (EM)

issues this Administrative Compliance Order ("Order") to the United States Department of Energy ("DOE"), and Nuclear Waste Partnership, LLC ("NWP"; collectively, with DOE, the...

200

DOE Online  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Fermilab's Science Adventures! Fermilab's Science Adventures! DOE Online K-12 Instructional Resources ed.fnal.gov/doe/ The U.S. Department of Energy is committed to helping educate our nation's next generation of scientists. The following resources help teachers integrate the Internet into K-12 classroom instruction. DOE Labs General Instructional Units Online Resources Lesson Plans General References DOE Laboratory and Facility Education Home Pages (www-ed.fnal.gov/doe/doe_labs.html) Direct links for 27 education Websites at DOE national laboratories and facilities. Online Catalog (www-ed.fnal.gov/trc/library) Fermilab's Teacher Resource Center collection of 10,000+ PreK-12 instructional materials in science, mathematics and technology. Materials include tradebooks, curriculum materials, educational

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

DOE PAGES  

Office of Scientific and Technical Information (OSTI)

a useful reference. Find out more Do you have questions about DOE PAGESBeta content, procedures, or policies? More information is available at OSTI's Public Access Policy page and...

202

DOE News  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DEPARTMENT OF ENERGY SMALL BUSINESS SYMPOSIUM TO LINK LOCAL COMPANIES WITH HANFORD CONTRACTING OPPORTUNITIES RICHLAND, Wash. - The U.S. Department of Energy (DOE) at the Hanford...

203

DOE-STD-1030-96 | Department of Energy  

Energy Savers [EERE]

for, Lockouts and Tagouts, Chapter IX of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities DOE-STD-1030-95, DOE Standard Guide...

204

DOE-STD-1034-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

for, Timely Orders to Operators, Chapter XV of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. DOE-STD-1034-93, Guide to Good...

205

DOE Standards and Corresponding Directives Crosswalk  

Broader source: Energy.gov (indexed) [DOE]

DOE Standards and Corresponding Directives Crosswalk DOE Standard Title Date DOE Order(s) Referenced Does DOE Order Reference Standard(s) DOE-TSL-1-99 Department of Energy Standards Index 5/99 ½ None ½ N/A. DOE-TSL-2-98 Directory of Points of Contact for the DOE Technical Standards Program 1/88 ½ None ½ N/A. DOE-TSL-4-99 Directory of DOE and Contractor Personnel Involved in Non- Government Standards Activities 5/99 ½ None ½ N/A. DOE-STD-0100T-93 Licensed Reactor Nuclear Safety Criteria Applicable to DOE Reactors 11/93 ½ DOE O 5480.6 ½ Order has been cancelled by N 251.4. DOE-STD-101-92 Compilation of Nuclear Safety Criteria for Potential Application to DOE Nonreactor Nuclear Facilities 3/92 ½ DOE O 5480.5 ½ Order has been cancelled by N 1321.140. DOE-HDBK-1001-96

206

International Refrigeration: Order (2012-CE-1510) | Department...  

Broader source: Energy.gov (indexed) [DOE]

Refrigeration: Order (2012-CE-1510) July 20, 2012 DOE ordered International Refrigeration Products to pay an 8,000 civil penalty after finding International Refrigeration had...

207

DOE017-0153  

Broader source: Energy.gov (indexed) [DOE]

5525 5525 DOE017-0153 ,-.or/ N"( - ./,'-'S MaryBeth Zimmerman 02/14/2001 11:08AM / -- T ' ,44 L - ( _w _1_'- _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - .I f . J To: Kenneth Friedman/EE/DOE@DOE, Peggy Podolak/EE/DOE@DOE, Linda Silverman/EE/DOE@DOE, Ed Wall/EE/DOE@DOE, David RodgerslEE/DOE@DOE, Jerry DionlEE/DOE@DOE, Gail McKinley/EE/DOE@DOE. Lawrence MansuetifEE/DOE@DOE cc: John Sullivan/EE/DOE@DOE. Darrell Beschen/EEIDOE@DOE, Michael York/EE/DOE@DOE, Buddy GarlandlEEIDOE@DOE, Nancy Jefferv/EEIDOE@DOE, Joel Rubin/EE/DOE@DOE. Sam Baldwin/EE/DOE@DOE, IEE-ADAS Subject: FW: NEP Draft outline Directions on NEP Assessment paper. Please read all of this very carefully before proceeding: Product Schedule: * Inputs due from sectors to Planning: COB on Thursday (sorry) o Due from EERE to Policy Office: noon on Friday

208

DOE PAGES  

Office of Scientific and Technical Information (OSTI)

States Government purposes. (End of Notice) Ref. DEAR970.5227-2 Rights in data-technology transfer DOE-funded authors are free to publish in journals of their choice, including...

209

DOE Approved Technical Standards | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

DOE Technical Standards Program » DOE DOE Technical Standards Program » DOE Approved Technical Standards DOE Approved Technical Standards Document ID Filter Document ID sort ascending Title Date DOE-STD-7501-99 The DOE Corporate Lessons Learned Programs Superseding DOE-STD-7501-95 Including Change Notice No. 1 (September 1997) This technical standard provides management expectations and a framework for the DOE Corporate Lessons Learned Program. The framework is intended to support development and implementation of a DOE-wide lessons learned infrastructure 01/20/2000 DOE-STD-6005-01 Industrial Hygiene Practices This standard recommends industrial hygiene practices to support components of the Worker Protection Program required by Department of Energy (DOE) Order 440.1A, “Worker Protection Management for DOE Federal and Contractor Employees. 04/30/2001

210

DOE-TSPP-9, Maintenance of DOE Technical Standards - July 1, 2009 |  

Broader source: Energy.gov (indexed) [DOE]

DOE-TSPP-9, Maintenance of DOE Technical Standards - July 1, 2009 DOE-TSPP-9, Maintenance of DOE Technical Standards - July 1, 2009 DOE-TSPP-9, Maintenance of DOE Technical Standards - July 1, 2009 Technical Standards Program Procedures (TSPP) - August 26, 2009 This procedure provides guidance for the routine maintenance of DOE Technical Standards. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as "DOE Components") working to the latest revision of DOE Order 252.1, "Technical Standards Program." DOE-TSPP-9, Maintenance of DOE Technical Standards - July 1, 2009 More Documents & Publications DOE-TSPP-9, Maintenance of DOE Technical Standards - August 1, 2000 MAINTENANCE OF DOE TECHNICAL STANDARDS

211

DOE-TSPP-9, Maintenance of DOE Technical Standards - August 1, 2000 |  

Broader source: Energy.gov (indexed) [DOE]

DOE-TSPP-9, Maintenance of DOE Technical Standards - August 1, 2000 DOE-TSPP-9, Maintenance of DOE Technical Standards - August 1, 2000 DOE-TSPP-9, Maintenance of DOE Technical Standards - August 1, 2000 Technical Standards Program Procedures (TSPP) This procedure provides guidance for the routine maintenance of DOE Technical Standards. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as "DOE Components") working to the latest revision of DOE Order 252.1, "Technical Standards Program." DOE-TSPP-9, Maintenance of DOE Technical Standards - August 1, 2000 More Documents & Publications DOE-TSPP-9, Maintenance of DOE Technical Standards - July 1, 2009 MAINTENANCE OF DOE TECHNICAL STANDARDS

212

DOE-STD-3022-98; DOE Standard DOE HEPA Filter Test Program  

Broader source: Energy.gov (indexed) [DOE]

22-98 22-98 May 1998 Superseding DOE NE F 3-42 January 1987 DOE STANDARD DOE HEPA FILTER TEST PROGRAM U.S. Department of Energy FSC 4460 Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 605-6000. Order No. DE98001294 DOE-STD-3022-98 iii FOREWORD 1. This Department of Energy (DOE) Standard is approved for use by all DOE components and contractors.

213

DOE-STD-1077-94  

Broader source: Energy.gov [DOE]

Training Accreditation Program Standard: Requirements and Guidelines Canceled | Supercedes DOE-STD-0101T, TAP-1, and DOE-STD-0103T, TAP-3 The purpose of this Standard is to provide requirements, information, and guidance for the effective implementation of the DOE Training Accreditation Program established by DOE Order 5480.18B, Nuclear Facility Training Accreditation Program.

214

DOE-STD-1027-92  

Broader source: Energy.gov [DOE]

Hazard Categorization and Accident Analysis Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports Change Notice No. 1 (September 1997) The purpose of this DOE Standard is to establish guidance for the preparation and review of hazard categorization and accident analyses techniques as required in DOE Order 5480.23, Nuclear Safety Analysis Reports.

215

Four Central Air Conditioners Determined Noncompliant With Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Four Central Air Conditioners Determined Noncompliant With Energy Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard Four Central Air Conditioners Determined Noncompliant With Energy Efficiency Standard October 3, 2011 - 9:21am Addthis The U.S. Department of Energy's Office of Enforcement issued a Notice of Noncompliance Determination (Notice) on September 27, 2011, to AeroSys, Inc. (AeroSys) regarding four models of central (through-the-wall) air conditioners that fail to meet Federal energy efficiency requirements. DOE tests revealed that AeroSys through-the-wall air conditioner models THDC-18S, THDC-18T, THDC-24S, and THDC-24T do not meet the minimum energy efficiency requirements set forth in DOE regulations. The Notice provides that AeroSys must inform those to whom it has sold the models that they do

216

Maintenance Management Program for DOE Nuclear Facilities  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To define the program for the management of cost-effective maintenance of Department of Energy (DOE) nuclear facilities. Guidance for compliance with this Order is contained in DOE G 433.1-1, Nuclear Facility Maintenance Management Program Guide for use with DOE O 433.1, which references Federal regulations, DOE directives, and industry best practices using a graded approach to clarify requirements and guidance for maintaining DOE-owned Government property. (Cancels DOE 4330.4B, Chapter II, Maintenance Management Program, dated 2-10-94.) Cancels DOE 4330.4B (in part). Canceled by DOE O 433.1A.

2001-06-01T23:59:59.000Z

217

Lumiram Electric: Order (2010-CE-1014) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Lumiram Electric: Order (2010-CE-1014) Lumiram Electric: Order (2010-CE-1014) November 23, 2010 DOE issued an Order and entered into a Compromise Agreement with Lumiram Electric...

218

INTERPRETATION REGARDING THE APPLICATION OF DOE TECHNICAL STANDARD...  

Broader source: Energy.gov (indexed) [DOE]

THE APPLICATION OF DOE TECHNICAL STANDARD 1027-92, HAZARD CATEGORIZATION AND ACCIDENT ANALYSIS TECHNIQUES FOR COMPLIANCE WITH DOE ORDER 5480.23, NUCLEAR SAFETY ANALYSIS REPORTS,...

219

DOE-HDBK-1208-2012 | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

of the DOE "core analytical techniques" for conducting a DOE Federal-, or contractor-led Accident Investigation or an OSR in order to prevent accidents. The analysis techniques...

220

DOE-STD-1031-92 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

direction for, Communications, Chapter IV of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. The practices in this guide should...

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

DOE-STD-1042-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

for, "Control Area Activities," Chapter III of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities."Control Area Activities" is an...

222

DOE-STD-1037-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Chemistry and Unique Processes, Chapter XIII of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. The practices in this guide should...

223

DOE-STD-1041-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

and Operating Practices," Chapter II of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. "Shift Routines and Operating...

224

Complexity: Order contra Chaos  

E-Print Network [OSTI]

Complexity: Order contra Chaos James P. Crutchfield Physics Department University of California. Philosophical consequences of deterministic chaos are noted. Appearing in Handbook of Metaphysics and Ontology's behaviour is symbolically specified in its entirety. How does unpredictability arise in such a situation

Crutchfield, Jim

225

RPAM & Energy Order Requirements  

Broader source: Energy.gov (indexed) [DOE]

430.1C, Real Property Asset Management 430.1C, Real Property Asset Management and DOE O 430.2B, Departmental Energy, Renewable Energy and Transportation Management Requirements, Overlap & Differences Office of Engineering and Construction Management September 2009 2 10/27/2009 Energy Order & RPAM Order Requirements DOE O 430.1C - RPAM DOE O 430.2B ENERGY ORDER Energy Efficiency Water Consumption Utility Metering ESPCs & USPCs Personnel - Energy Training Environmental Management System (EMS) Real Property Performance Indicators Sustainable Buildings Facilities Information Management System (FIMS) Personnel - Certified Realty Specialists Ten Year Site Plans Sustainable & Integrated Design TEAM Executable Plans High Performance Building Plan OVERLAP Real Property

226

DOE Report  

Broader source: Energy.gov (indexed) [DOE]

2 2 Environmental Assessment for the Multipurpose Haul Road Within the Idaho National Laboratory Site August 2010 DOE/EA-1772 Environmental Assessment for the Multipurpose Haul Road Within the Idaho National Laboratory Site August 2010 CONTENTS ACRONYMS.............................................................................................................................................. vii GLOSSARY ................................................................................................................................................ ix 1. PURPOSE AND NEED ..................................................................................................................... 1 1.1 Background ...........................................................................................................................

227

DOE Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

772 772 Environmental Assessment for the Multipurpose Haul Road Within the Idaho National Laboratory Site August 2010 DOE/EA-1772 Environmental Assessment for the Multipurpose Haul Road Within the Idaho National Laboratory Site August 2010 CONTENTS ACRONYMS.............................................................................................................................................. vii GLOSSARY ................................................................................................................................................ ix 1. PURPOSE AND NEED ..................................................................................................................... 1 1.1 Background ...........................................................................................................................

228

order form  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Customer Order Form Customer Order Form Fermilab Education Office - Customer Order Form PO BOX 500, MS 777, Batavia, IL 60510 * ph. 630-840-8258 * fax 630-840-2500 * avarry@fnal.gov Date: This order be: SHIPPED PICKED UP? Bill to: Ship to: Contact/Institution name: Email: Phone: Fax: Payment method (please circle): Visa/MasterCard - Check - Purchase Order  Visa/MasterCard # P.O. # Exp Date: Quantity Ordered Item Name Item Description (color, size, etc.) Price Each Total Amount  For purchases over $200 only *IL residents ONLY: Add 7.5% sales tax to your order.

229

DOE Retro Analysis Plan  

Broader source: Energy.gov (indexed) [DOE]

Retro Analysis Plan Retro Analysis Plan August 2, 2011 Page 1 August 2, 2011 Daniel Cohen, Esq. Office of General Counsel U.S. Department of Energy 1000 Independence Avenue, SW Washington, DC 20585 Re: Preliminary Plan for Retrospective Analysis Dear Mr. Cohen: These comments are submitted by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) in response to the U.S. Department of Energy's (DOE) notice appearing in the July 11, 2011 Federal Register requesting comments on the Preliminary Plan for Retrospective Analysis of Existing Rules. We are encouraged by DOE's efforts to implement Executive Order 13563. We appreciate the actions already taken by DOE to address our concerns regarding the Final Rule on Certification, Compliance, and Enforcement Regulations for Consumer Products and Commercial and

230

Consent Order, Battelle Energy Alliance- NCO-2014-02  

Broader source: Energy.gov [DOE]

Nuclear Safety Enforcement Consent Order issued to Battelle Energy Alliance for deficiencies associated with multiple core misload events at DOEs Idaho National Laboratory.

231

DOE-TSPP-6-2013, Approving and Issuing DOE Technical Standards | Department  

Broader source: Energy.gov (indexed) [DOE]

6-2013, Approving and Issuing DOE Technical Standards 6-2013, Approving and Issuing DOE Technical Standards DOE-TSPP-6-2013, Approving and Issuing DOE Technical Standards Technical Standards Program Procedures (TSPP) - September 16, 2013 This procedure provides guidance for approving and issuing the Department of Energy (DOE) Technical Standards. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as Technical Standards Program (TSP) participants) working to the latest revision of DOE Order (O) 252.1A, Technical Standards Program. DOE-TSPP-6-2013, Approving and Issuing DOE Technical Standards More Documents & Publications DOE-TSPP-7-2013, Maintaining DOE Technical Standards DOE-TSPP-6, Coordination of DOE Technical Standards - July 1, 2009

232

DOE-TSPP-8, Approving and Issuing DOE Technical Standards - August 1, 2000  

Broader source: Energy.gov (indexed) [DOE]

TSPP-8, Approving and Issuing DOE Technical Standards - August TSPP-8, Approving and Issuing DOE Technical Standards - August 1, 2000 DOE-TSPP-8, Approving and Issuing DOE Technical Standards - August 1, 2000 Technical Standards Program Procedures (TSPP) This procedure provides guidance for approving and issuing DOE Technical Standards. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as "DOE Components") working to the latest revision of DOE Order 252.1, "Technical Standards Program." DOE-TSPP-8, Approving and Issuing DOE Technical Standards - August 1, 2000 More Documents & Publications APPROVING AND ISSUING DOE TECHNICAL STANDARDS DOE-TSPP-8, Approving and Issuing DOE Technical Standards - July 1, 2009

233

DOE O 482.1  

Broader source: Energy.gov (indexed) [DOE]

Department of Energy ORDER Department of Energy ORDER Washington, D.C. Approved: 01-12-01 Sunset Review: 01-12-03 Expires: 01-12-05 SUBJECT: DOE FACILITIES TECHNOLOGY PARTNERING PROGRAMS 1. OBJECTIVES. a. To establish Department of Energy (DOE) policy, consistent with the terms of the facility contract or delegation of authority, to- (1) facilitate the efficient and expeditious development, transfer, and exploitation of Federally owned or originated technology to non-DOE entities for the public benefit and to enhance the accomplishment of DOE missions; (2) leverage DOE resources, through its programs and facilities, through partnering; and (3) ensure fairness of opportunity, protect the national security, promote the economic interests of the United States, prevent inappropriate competition with

234

Curtis: Order (2015-CE-14021)  

Broader source: Energy.gov [DOE]

DOE ordered Curtis International, Ltd. to pay a $5,800 civil penalty after finding Curtis had failed to certify that refrigerator-freezer basic model FR9211 complies with the applicable energy conservation standards.

235

LG: Order (2015-CE-14022)  

Broader source: Energy.gov [DOE]

DOE ordered LG Electronics USA, Inc. to pay a $8,000 civil penalty after finding LG had failed to certify that various refrigerator-freezer basic models comply with the applicable energy conservation standards.

236

Legacy: Order (2015-CE-14025)  

Broader source: Energy.gov [DOE]

DOE ordered The Legacy Companies to pay a $8,000 civil penalty after finding Legacy had failed to certify that refrigerator Maxx-Ice brand basic model MCR3U complies with the applicable energy conservation standards.

237

Trastar: Order (2013-CE-49003)  

Broader source: Energy.gov [DOE]

DOE ordered Trastar Inc. to pay a $8,000 civil penalty after finding Trastar had failed to certify that certain basic models of traffic signal modules and pedestrian modules comply with the applicable energy conservation standards.

238

Keystone: Order (2013-CE-2601)  

Broader source: Energy.gov [DOE]

DOE ordered Keystone Technologies, LLC to pay a $8,000 civil penalty after finding Keystone had failed to certify that certain models of fluorescent lamp ballasts comply with the applicable energy conservation standards.

239

Trojan: Order (2011-CE-2704)  

Broader source: Energy.gov [DOE]

DOE ordered Trojan, Inc. to pay a $6,000 civil penalty after finding Trojan had failed to certify that certain models of incandescent reflector lamps comply with the applicable energy conservation standards.

240

Electrolux: Order (2014-CE-23015)  

Broader source: Energy.gov [DOE]

DOE ordered Electrolux North America, Inc. to pay a $16,000 civil penalty after finding Electrolux had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Whirlpool: Order (2014-CE-21010)  

Broader source: Energy.gov [DOE]

DOE ordered Whirlpool Corporation to pay a $8,000 civil penalty after finding Whirlpool had failed to certify that certain models of residential clothes dryers comply with the applicable energy conservation standards.

242

Dacor: Order (2014-CE-23010)  

Broader source: Energy.gov [DOE]

DOE ordered Dacor to pay a $8,000 civil penalty after finding Dacor had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

243

Northland: Order (2014-CE-23002)  

Broader source: Energy.gov [DOE]

DOE ordered Northland Corporation d/b/a AGA Marvel to pay a $16,000 civil penalty after finding Northland had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

244

CRAD, Feedback and Continuous Improvement - DOE Headquarters...  

Energy Savers [EERE]

2, quality assurance requirements (as stated in 10 Code of Federal Regulations (CFR) 830, Subpart A, DOE Order 414.1 C, Quality Assurance, or other applicable...

245

Personnel Security - DOE Directives, Delegations, and Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

472.2 Chg 1, Personnel Security by Mark Pekrul Functional areas: Personnel Security, Security, Human Capital The order establishes requirements that will enable DOE to operate a...

246

DOE-STD-1038-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

for, Operations Turnover, Chapter XII of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. DOE-STD-1038-93, Guide to Good...

247

DOE-STD-1044-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

and Piping Labeling," Chapter XVIII of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. DOE-STD-1044-93 CN-1, Guide to Good...

248

DOE-STD-1039-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

of Equipment and System Status, Chapter VIII of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. DOE-STD-1039-93, Guide to Good...

249

DOE-STD-1032-92 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Organization and Administration, Chapter I of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. DOE-STD-1032-92 Change Notice 1,...

250

DOE-STD-1043-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

for, Operator Aid Postings, Chapter XVII of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. DOE-STD-1043-93 CN-1, Guide to Good...

251

DOE-STD-1035-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

direction for, Logkeeping, Chapter XI of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. DOE-STD-1035-93, Guide to Good...

252

Environmental Protection, Safety, and Health Protection Program for DOE Operations  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Order establishes the Environmental Protection, Safety. and Health Protection Program for Department of Energy (DOE) operations. Cancels DOE 5480.1, dated 5-5-1980, its chapters are not canceled. Canceled by DOE O 5480.1B

1981-08-13T23:59:59.000Z

253

DOE News  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

as the Vit Plant, will ultimately treat the waste in order to prepare it for safe, long-term storage. The Department has added the video to a page on its website dedicated to...

254

DOE O 483.1  

Broader source: Energy.gov (indexed) [DOE]

Department of Energy Department of Energy ORDER Washington, D.C. Approved: 01-12-01 Sunset Review: 01-12-03 Expiration: 01-12-05 SUBJECT: DOE COOPERATIVE RESEARCH AND DEVELOPMENT AGREEMENTS 1. OBJECTIVES. a. To establish Department of Energy (DOE) policy, requirements, and responsibilities for the oversight, management, and administration of Cooperative Research and Development Agreement (CRADA) activities at DOE facilities. b. Through the use of CRADAs, consistent with the terms of the facility contract or delegation of authority, DOE and its facilities will- (1) facilitate the efficient and expeditious development, transfer, and exploitation of Federally owned or originated technology to non-DOE entities for the public benefit and to enhance the accomplishment of DOE missions;

255

DOE F 5631.25  

Broader source: Energy.gov (indexed) [DOE]

5 5 (07/2012) All Other Editions Are Obsolete U.S. DEPARTMENT OF ENERGY FILE TRANSFER RECORD THE FOLLOWING PERSONNEL SECURITY FILE(S) IS/ARE TRANSMITTED AS INDICATED: NAME (LAST, FIRST, MIDDLE) DOE NUMBER RECEIVING OFFICE SYMBOL REVIEW AND RETURN RETAIN PRIVACY ACT STATEMENT - Collection of the information requested is authorized by Department of Energy (DOE) Order 472.2, "Personnel Security." The information placed on this form is used to officially transmit DOE Personnel Security Files (PSFs) among DOE Cognizant Personnel Security Offices and authorized officials. Copies of this document may be maintained in PSFs and personnel security administrative files as necessary. Access to DOE PSFs is permitted as stipulated in DOE O

256

Paperclips Etc. Special Order Form  

Broader source: Energy.gov (indexed) [DOE]

PSS-02.2 (March 7, 2011) Replaces PSS-02.1 PSS-02.2 (March 7, 2011) Replaces PSS-02.1 PAPERCLIPS Etc. SPECIAL Orders Form This form is used to order supplies that are not readily available in the DOE HQ self-service supply stores or for items that require approval by Office Management. All supplies ordered MUST be used for Official Government Business only. Requestor's Name: ___________________________________________________ Date: __________________ Phone Number: __________________ DOE ID Badge No.: ________________________________________ Catalog Name: ______________________________________________________ Org Code: ______________ Item Number Page # Item Description Quantity Store Use Only ALL printed names (legible), signatures and dates are required before your Special order is processed.

257

LLNS Beryllium Consent Order Fact Sheet  

Broader source: Energy.gov (indexed) [DOE]

- LLNS Beryllium Consent Order - LLNS Beryllium Consent Order SUMMARY OF CONSENT ORDER In November 2010, the U.S. Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) issued a consent order to Lawrence Livermore National Security, LLC (LLNS) for deficiencies related to LLNS's implementation of DOE's Chronic Beryllium Disease Prevention Program (CBDPP) regulation at Lawrence Livermore National Laboratory. The consent order requires LLNS to implement corrective actions that will ensure LLNS meets DOE requirements for assessing and controlling beryllium hazards and minimizes potential worker exposures to legacy beryllium hazards in Laboratory buildings. Under the terms of the consent order, LLNS agrees to implement corrective actions that address the

258

DOE-STD-1029-92 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Guide for Technical Procedures More Documents & Publications Microsoft Word - Policy Flash 2010-73 Attachment 5 Order Module--DOE Order 422.1, CONDUCT OF OPERATIONS DOE-STD-1068-94...

259

DOE-TSPP-10, Conversion of DOE Technical Standards to Non-Government  

Broader source: Energy.gov (indexed) [DOE]

DOE-TSPP-10, Conversion of DOE Technical Standards to DOE-TSPP-10, Conversion of DOE Technical Standards to Non-Government Standards - August 1, 2000 DOE-TSPP-10, Conversion of DOE Technical Standards to Non-Government Standards - August 1, 2000 Technical Standards Program Procedures (TSPP) This procedure provides guidance on the conversion of DOE Technical Standards to Voluntary Consensus Standards (VCSs), also referred to as non-Government standards. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as "DOE Components") working to the requirements of the latest revision of DOE Order 252.1, "Technical Standards Program." DOE-TSPP-10, Conversion of DOE Technical Standards to Non-Government

260

DOE-TSPP-2-2013, Initiating DOE Technical Standards | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

2-2013, Initiating DOE Technical Standards 2-2013, Initiating DOE Technical Standards DOE-TSPP-2-2013, Initiating DOE Technical Standards Technical Standards Program Procedures (TSPP) - September 16, 2013 This procedure provides guidance on how to establish and justify the need for a Department of Energy (DOE) Technical Standard and register a DOE Technical Standard Project. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as Technical Standards Program (TSP) participants) working to DOE Order (O) 252.1A, Technical Standards Program. DOE-TSPP-2-2013, Initiating DOE Technical Standards More Documents & Publications DOE-TSPP-8-2013, Converting DOE Technical Standards to Voluntary Consensus

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

DOE Onboarding  

Broader source: Energy.gov (indexed) [DOE]

One-Year Passport to Success One-Year Passport to Success What is On-boarding? Orientation On-boarding  Transactional focus and goals  Less than one week  Executed by HR Office  Address new employee needs  Completed paperwork  Strategic focus and goals  Starts before first day through first year  Supervisor & Senior Leadership involvement  Integrate multiple offices, functions and individuals  Address employee needs  Maximizes employee engagement and retention 2 On-boarding Program Goals 3  Build and sustain high-performance culture by accelerating time for new employee to become productive  Create learning opportunities that allow new employees to successfully integrate into their new DOE organization  Provide employees with the tools and resources to

262

DOE 11  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DOE A ward N o.: D E--NT0005665 Final T echnical R eport (October 2 008 - S eptember 2 012) Source c haracterization a nd t emporal variation o f m ethane s eepage f rom thermokarst l akes o n t he A laska N orth S lope in r esponse t o A rctic c limate c hange Submitted b y: University o f A laska Fairbanks, A K 9 9775 Prepared for: United S tates D epartment o f E nergy National E nergy T echnology L aboratory May 29 th 2013 Office of Fossil Energy 2 DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any

263

DOE Pulse  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

go! go! home about archives subscribe Profile Dr. Isaac Gamwo (left) works with Dr. Ward Burgess (right) at the National Energy Technology Laboratory. Photo Credit: NETL. The practical application of an elite researcher's life: Isaac K. Gamwo For a man whose expertise includes reactive multiphase fluid dynamics, complex fluid properties, and chemical looping combustion processes, Dr. Isaac Gamwo is surprisingly easy to comprehend. "The research we do in this lab is not confined to the world of academia," he notes, "it has tangible impacts on the way we produce energy." As senior research chemical engineer at DOE's National Energy Technology Laboratory (NETL), Dr. Gamwo is currently focused on complex fluid properties at high temperatures and pressures. His recent work includes

264

DOE Code:  

Broader source: Energy.gov (indexed) [DOE]

we1rbox installatiOn we1rbox installatiOn ____:....;...=.~;;....:..;=-+- DOE Code: - - !- Project Lead: Wes R1esland NEPA COMPLIANCE SURVEY J 3-24-10 1 Date: Project Information 1. Project Overview What are tne enwonmental mpacts? Contractor~~ _ _ _ _ ] 11 The purpose of this project is to prepare a pad for a 90 ton crane to get 1nto positiOn and ng up so we can 1 set our new weir box into position We will widen the existing road around 20 feet at the north end and taper our fill to about5 feet at the south end for a total of about 200 feeL and budd a near level pad for them tong up the crane on We will use the d1rt from the hill irnrnedJateiy north of the work to oe done 2. 3 4 What*s the legal location? What IS the durabon of the prOJed?

265

DOE F  

Broader source: Energy.gov (indexed) [DOE]

420.2 420.2 All Other Editions Are Obsolete OMB Burden Disclosure Statement Public reporting burden for this collection of information is estimated to average 30 minutes per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Records Management Division, IM-11 GTN, Paperwork Reduction Project (1910-1000), U.S. Department of Energy, 1000 Independence Avenue, S.W., Washington, DC 20585; and to the Office of Management and Budget (OMB), Paperwork Reduction Project (1910-1000), Washington, DC 20503. U.S. Department of Energy Personal Property Loan Agreement DOE-PMR 109-1.5103 1. CONTROL

266

DOE executes a diverse portfolio of capital asset projects supporting...  

Broader source: Energy.gov (indexed) [DOE]

impacting the project must be endorsed by the project's Acquisition Executive per DOE Order 413.3B (the Order). Selecting an appropriate acquisition strategy, establishing a...

267

Active DOE Technical Standards  

Broader source: Energy.gov (indexed) [DOE]

Active DOE Technical Standards Active DOE Technical Standards Document Number Document Title Responsible SLM DOE-HDBK-1001-96 DOE-HDBK-1002-96 DOE-HDBK-1003-96 DOE-HDBK-1010-92 DOE-HDBK-1011/1-92 DOE-HDBK-1011/2-92 DOE-HDBK-1011/3-92 DOE-HDBK-1011/4-92 DOE-HDBK-1012/1-92 DOE-HDBK-1012/2-92 DOE-HDBK-1012/3-92 DOE-HDBK-1013/1-92 DOE-HDBK-1013/2-92 DOE-HDBK-1014/1-92 DOE-HDBK-1014/2-92 DOE-HDBK-1015/1-93

268

DOE-HDBK-1092-98; DOE Handbook Electrical Safety  

Broader source: Energy.gov (indexed) [DOE]

092-98 092-98 January 1998 DOE HANDBOOK ELECTRICAL SAFETY U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE98001290 DOE-HDBK-1092-98 DOE-HDBK-1092-98 CONTENTS 1.0 INTRODUCTION 2.0 GENERAL REQUIREMENTS 3.0 ELECTRICAL PREVENTIVE MAINTENANCE 4.0 GROUNDING 5.0 SPECIAL OCCUPANCIES 6.0 REQUIREMENTS FOR SPECIFIC EQUIPMENT

269

Interlocutory Order  

Broader source: Energy.gov (indexed) [DOE]

8, 2011 8, 2011 DEPARTMENT OF ENERGY OFFICE OF HEARINGS AND APPEALS Motion to Dismiss Initial Agency Decision Names of Petitioner: Eugene N. Kilmer Los Alamos National Security, LLC Dates of Filings: March 1, 2010 March 24, 2011 Case Numbers: TBH-0111 TBZ-0111 This Decision will consider a Motion to Dismiss filed by Los Alamos National Security, LLC (LANS), the Management and Operating Contractor for the Department of Energy's (DOE) Los Alamos National Laboratory (LANL), in connection with the pending Complaint of Retaliation filed by Eugene N. Kilmer against LANS under the DOE's Contractor Employee Protection Program and its governing regulations set forth at 10 C.F.R. Part 708. The Office of Hearings and Appeals (OHA) assigned the hearing component of Kilmer's Part 708 Complaint proceeding, Case No. TBH-0111,

270

DOE-TSPP-6, Coordination of DOE Technical Standards - July 1, 2009 |  

Broader source: Energy.gov (indexed) [DOE]

DOE-TSPP-6, Coordination of DOE Technical Standards - July 1, 2009 DOE-TSPP-6, Coordination of DOE Technical Standards - July 1, 2009 DOE-TSPP-6, Coordination of DOE Technical Standards - July 1, 2009 Technical Standards Program Procedures (TSPP) - August 26, 2009 This procedure provides guidance on the formal coordination of DOE Technical Standards in the DOE Technical Standards Program (TSP). The purpose of coordination of draft technical standards is to solicit and receive comments from interested persons and organizations in order to improve and correct technical standards. DOE Technical Standards are coordinated through the electronic RevCom for TSP process. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, integrating contractors, and laboratories (hereafter referred to collectively as "DOE

271

DOE O 534.1B  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Departmental Elements Departmental Elements Office of Chief Financial Officer DOE O 534.1B U.S. Department of Energy ORDER Washington, D.C. Approved: 01-06-03 SUBJECT: ACCOUNTING 1. OBJECTIVE. To prescribe the requirements and responsibilities for the accounting and financial management of the Department of Energy (DOE). 2. CANCELLATION. DOE O 534.1A, Accounting, dated 7-5-01. Cancellation of an Order does not, by itself, modify or otherwise affect any contractual obligation to comply with such an Order. Canceled Orders incorporated by reference in a contract remain in effect until the contract is modified to delete the reference to the requirements in the canceled Orders. 3. APPLICABILITY. a. DOE Elements. To ensure sound financial management and overall consistency in exercising the financial management statutory authorities that vest in the

272

Order Module--NNSA OCCUPATIONAL RADIATION PROTECTION | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Order Module--NNSA OCCUPATIONAL RADIATION PROTECTION Order Module--NNSA OCCUPATIONAL RADIATION PROTECTION Order Module--NNSA OCCUPATIONAL RADIATION PROTECTION The familiar level of this module is designed to provide the basic information to meet the requirements that are related to 10 CFR 835, "Occupational Radiation Protection," in the following DOE Functional Area Qualification Standards: DOE-STD-1177-2004, Emergency Management DOE-STD-1151-2002, Facility Representative DOE-STD-1146-2007, General Technical Base DOE-STD-1138-2007, Industrial Hygiene DOE-STD-1183-2007, Nuclear Safety Specialist DOE-STD-1174-2003, Radiation Protection DOE-STD-1175-2006, Senior Technical Safety Manager DOE-STD-1178-2004, Technical Program Manager DOE-STD-1155-2002, Transportation and Traffic Management DOE Order Self Study Modules - 10 CFR 835 Occupational Radiation Protection

273

DOE-STD-0100T; DOE Standard Licensed Reactor Nuclear Safety Criteria Applicable to DOE Reactors  

Broader source: Energy.gov (indexed) [DOE]

00T 00T November 1993 Superseding DOE/NE-0100T April 1991 DOE STANDARD LICENSED REACTOR NUCLEAR SAFETY CRITERIA APPLICABLE TO DOE REACTORS U.S. Department of Energy Washington, D.C. 20585 AREA SAFT DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly frorn the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE94005221 CONTENTS

274

FirstOrder CarnegieMellon  

E-Print Network [OSTI]

the order of universal quantifiers does not change the meaning: (Ax)(Ay)P(x,y) is logically equivalent of universals and existentials does change meaning: -- Everyone likes someone: (Ax)(Ey)likes(x,y) -- SomeoneFirst­Order Logic (FOL) aka. predicate calculus Tuomas Sandholm CarnegieMellon University Computer

Sandholm, Tuomas W.

275

EXECUTIVE ORDER 13514  

Broader source: Energy.gov (indexed) [DOE]

ORDER 13514 ORDER 13514 FEDERAL LEADERSHIP IN ENVIRONMENTAL, ENERGY AND ECONOMIC PERFORMANCE FAR and DEAR Implementation and User Aids. 1 Notice a Pattern * Third President in a Row to do this! * Clinton had 5 Greening Orders starting with 13101. * Bush trumped him by putting it all in one, i.e., EO 13423, [Did you know? Congress made this permanent by placing it in a continuing resolution!]. * Obama trumped him by adding Green House Gases and Plug In Hybrids in EO 13514. 2 FAR Case 2010-001 Sustainable Acquisition - What's New * A new 23.002 is established aimed directly at DOE. It repeats E.O. 13423, Section 3(e) requirement that contracts for Contractor operation of a Government facility must contain a clause requiring the Contractor to comply with E.O. 13423 to

276

Laws DOE Administers | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Laws DOE Administers Laws DOE Administers Laws DOE Administers The Department of Energy's (DOE) overarching mission is to advance the national, economic, and energy security of the United States; to promote scientific and technological innovation in support of that mission; and to ensure the environmental cleanup of the national nuclear weapons complex. Laws passed by Congress and signed by the President both define DOE's authorities and set forth DOE's responsibilities. Additionally, a number of Executive Orders issued by the President play a central role in guiding DOE's activities. In the space below, we have provided links to key statutes and executive orders which affect the Department of Energy. For every law, we provide a link to the United States Code (U.S.C.) , which is the codification by

277

DOE-TSPP-5, Development of a New DOE Technical Standard - July 1, 2009 |  

Broader source: Energy.gov (indexed) [DOE]

5, Development of a New DOE Technical Standard - July 1, 5, Development of a New DOE Technical Standard - July 1, 2009 DOE-TSPP-5, Development of a New DOE Technical Standard - July 1, 2009 Technical Standards Program Procedures (TSPP) - August 26, 2009 This procedure provides guidance for developing DOE Technical Standards. NOTE: Development of a Voluntary Consensus Standard (VCS) for DOE's use will follow the rules of the standards developing organization (SDO). The DOE representative to the standards-writing activity represents the Department's interests during VCS development. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as "DOE Components") working to the latest revision of DOE Order 252.1, "Technical Standards Program."

278

DOE-TSPP-9-2013, DOE Technical Standards Program Topical Committees |  

Broader source: Energy.gov (indexed) [DOE]

9-2013, DOE Technical Standards Program Topical Committees 9-2013, DOE Technical Standards Program Topical Committees DOE-TSPP-9-2013, DOE Technical Standards Program Topical Committees Technical Standards Program Procedures (TSPP) - September 16, 2013 This procedure describes how topical committees are organized and recognized under the Technical Standards Program. This procedure applies to all Department of Energy (DOE) Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as TSP participants) working to the latest revision of DOE Order (O) 252.1A, Technical Standards Program. DOE-TSPP-9-2013, DOE Technical Standards Program Topical Committees More Documents & Publications TECHNICAL STANDARDS PROGRAM TOPICAL COMMITTEES DOE-TSPP-8-2013, Converting DOE Technical Standards to Voluntary Consensus

279

DOE-STD-1091-96; DOE Standard Firearms Safety  

Broader source: Energy.gov (indexed) [DOE]

1-96 1-96 February 1996 DOE STANDARD FIREARMS SAFETY U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE96009493 DOE-STD-1091-96 iii CONTENTS PARAGRAPH PAGE Foreword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

280

DOE-STD-1027-92 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

DOE-STD-1027-92 DOE-STD-1027-92 DOE-STD-1027-92 December 12, 1997 Hazard Categorization and Accident Analysis Techniques for Compliance with DOE Order 5480.23, Nuclear Safety Analysis Reports Change Notice No. 1 (September 1997) The purpose of this DOE Standard is to establish guidance for the preparation and review of hazard categorization and accident analyses techniques as required in DOE Order 5480.23, Nuclear Safety Analysis Reports. DOE-STD-1027-92, Hazard Categorization and Accident Analysis Techniques For Compliance With DOE Order 5480.23, Nuclear Safety Analysis Reports More Documents & Publications NSTP 2002-2 Methodology for Final Hazard Categorization for Nuclear Facilities from Category 3 to Radiological (11/13/02). DOE-EM-STD-5502-94 INTERPRETATION REGARDING THE APPLICATION OF DOE TECHNICAL STANDARD 1027-92,

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

DOE-TSPP-6, Coordination of DOE Technical Standards - July 2004 |  

Broader source: Energy.gov (indexed) [DOE]

2004 2004 DOE-TSPP-6, Coordination of DOE Technical Standards - July 2004 Technical Standards Program Procedures (TSPP) - July 26, 2004 This procedure provides guidance on the formal coordination of DOE Technical Standards in the DOE Technical Standards Program (TSP). The purpose of coordination of draft technical standards is to solicit and receive comments from interested persons and organizations in order to improve and correct technical standards. DOE Technical Standards are coordinated through the electronic RevCom for TSP process. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, integrating contractors, and laboratories (hereafter referred to collectively as "DOE Components") working to the latest revision of DOE Order 252.1, "Technical

282

DOE Awards Support Service Contract  

Broader source: Energy.gov [DOE]

Cincinnati - The U.S. Department of Energy (DOE) today announced the award of a Firm-Fixed-Price task order off the Mixed Low-Level Waste (MLLW) Treatment Indefinite Delivery/Indefinite Quantity (ID/IQ) contract with Perma-Fix Environmental Services, LLC of Oakridge, TN.

283

News Archive | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

March 30, 2010 March 30, 2010 DOE Does Not Oppose Petitions to Intervene in Yucca Mountain NRC Proceeding The U.S. Department of Energy yesterday filed with the Nuclear Regulatory Commission a response to Petitions to Intervene filed by several parties seeking to oppose the Department's motion to withdraw its license application for a nuclear waste repository at Yucca Mountain. DOE said it is confident that its motion to withdraw the application is lawful, but that it believes the petitioning parties should be allowed to present their views to the NRC. March 30, 2010 DOE Orders AeroSys to Halt Distribution of Inefficient Air Conditioner and Heat Pump Models Shown to Violate Minimum Efficiency Standards WASHINGTON, DC - Today, the Department of Energy announced that it is

284

Page not found | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

71 - 14780 of 26,764 results. 71 - 14780 of 26,764 results. Article DOE Requires Manufacturers to Halt Sales of Heat Pumps and Air Conditioners Violating Minimum Appliance Standards Today, the Department of Energy announced that three manufacturers -- Aspen Manufacturing, Inc., Summit Manufacturing, and Advanced Distributor Products -- must stop distributing 61 heat pump... http://energy.gov/gc/articles/doe-requires-manufacturers-halt-sales-heat-pumps-and-air-conditioners-violating-minimum Article Aerosys Agrees to Pay Civil Penalty and Submit Test Data in Settlement with DOE WASHINGTON, DC - The Department of Energy announced today that AeroSys, Inc. has agreed to pay a civil penalty of $25,000 and take a number of other actions designed to ensure its future compliance... http://energy.gov/gc/articles/aerosys-agrees-pay-civil-penalty-and-submit-test-data-settlement-doe

285

LWX-0014 Supplemental Order  

Broader source: Energy.gov (indexed) [DOE]

4 4 DECISION AND ORDER OF THE DEPARTMENT OF ENERGY Supplemental Order Name of Petitioner: Ronald A. Sorri Date of Filing: September 26, 1994 Case Number: LWX-0014 This Decision supplements an Initial Agency Decision, dated December 16, 1993, issued by the undersigned Hearing Officer of the Office of Hearings and Appeals (OHA) of the Department of Energy in a case involving a "whistleblower" complaint filed by Ronald A. Sorri (Sorri) under the Department of Energy's Contractor Employee Protection Program, 10 C.F.R. Part 708. See Ronald A. Sorri, 23 DOE & 87,503 (1993) (Sorri). In the December 16 Decision, I found that Sorri had proven by a preponderance of the evidence that he engaged in activities protected under Part 708 and that these activities were a contributing

286

DOE-TSPP-4-2013, Developing DOE Technical Standards | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

-2013, Developing DOE Technical Standards -2013, Developing DOE Technical Standards DOE-TSPP-4-2013, Developing DOE Technical Standards Technical Standards Program Procedures (TSPP) - September 16, 2013 This procedure provides guidance for developing the Department of Energy (DOE) Technical Standards. NOTE: Development of a Voluntary Consensus Standard (VCS) for DOE's use will follow the rules of the Standards Developing Organization (SDO). The DOE representative to the standards-writing activity represents the Department's interests during VCS development. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as Technical Standards Program (TSP) participants) working to the latest revision of DOE Order (O) 252.1A, Technical Standards

287

DOE-TSPP-5, Development of a New DOE Technical Standard - August 1, 2000 |  

Broader source: Energy.gov (indexed) [DOE]

, Development of a New DOE Technical Standard - August 1, , Development of a New DOE Technical Standard - August 1, 2000 DOE-TSPP-5, Development of a New DOE Technical Standard - August 1, 2000 Technical Standards Program Procedures (TSPP) This procedure provides guidance for developing DOE Technical Standards. NOTE: Development of a Voluntary Consensus Standard (VCS) for DOE's use will follow the rules of the standards developing organization (SDO). The DOErepresentative to the standards-writing activity represents the Department's interests during VCS development. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as "DOE Components") working to the latest revision of DOE Order 252.1, "Technical Standards Program."

288

DOE-TSPP-8-2013, Converting DOE Technical Standards to Voluntary Consensus  

Broader source: Energy.gov (indexed) [DOE]

-2013, Converting DOE Technical Standards to Voluntary -2013, Converting DOE Technical Standards to Voluntary Consensus Standards DOE-TSPP-8-2013, Converting DOE Technical Standards to Voluntary Consensus Standards Technical Standards Program Procedures (TSPP) - September 16, 2013 This procedure provides guidance on the conversion of DOE Technical Standards to Voluntary Consensus Standards (VCSs). This procedure applies to all Department of Energy (DOE) Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as Technical Standards Program (TSP) participants) working to the requirements of the latest revision of DOE Order (O) 252.1A, Technical Standards Program. DOE-TSPP-8-2013, Converting DOE Technical Standards to Voluntary Consensus Standards

289

DOE-TSPP-5, Development of a New DOE Technical Standard - August 1, 2000 |  

Broader source: Energy.gov (indexed) [DOE]

TSPP-5, Development of a New DOE Technical Standard - August 1, TSPP-5, Development of a New DOE Technical Standard - August 1, 2000 DOE-TSPP-5, Development of a New DOE Technical Standard - August 1, 2000 Technical Standards Program Procedures (TSPP) This procedure provides guidance for developing DOE Technical Standards. NOTE: Development of a Voluntary Consensus Standard (VCS) for DOE's use will follow the rules of the standards developing organization (SDO). The DOErepresentative to the standards-writing activity represents the Department's interests during VCS development. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as "DOE Components") working to the latest revision of DOE Order 252.1, "Technical Standards Program."

290

Guide to good practices for timely orders to operators  

SciTech Connect (OSTI)

This Guide to Good Practices is written to enhance understanding of, and provide direction for, Timely Orders to Operators, Chapter XV of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. The practices in this guide should be considered when planning or reviewing Timely Orders to Operators programs. Contractors are advised to adopt procedures that meet the intent of DOE Order 5480.19. Timely Orders to Operators is an element of an effective Conduct of Operations program. The complexity and array of activities performed in DOE facilities dictate the necessity for timely orders to operators to promote safe and efficient operations.

NONE

1998-12-01T23:59:59.000Z

291

DOE-STD-1063-97; DOE Standard Establishing and Maintaining a Facility Representative Program at DOE Facilities  

Broader source: Energy.gov (indexed) [DOE]

3-97 3-97 October 1997 Supersedes DOE-STD-1063-93 DOE STANDARD ESTABLISHING AND MAINTAINING A FACILITY REPRESENTATIVE PROGRAM AT DOE FACILITIES U.S. Department of Energy AREA FACR Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE98001286 DOE-STD-1063-97 iii FOREWORD 1. This Department of Energy standard is approved for use by all DOE Components.

292

About / FAQ | DOE PAGES  

Office of Scientific and Technical Information (OSTI)

transition to a full release. DOE PAGESBeta represents DOE's response to the February 2013 Office of Science and Technology Policy memorandum that called on federal agencies to...

293

Maintenance Management Program for DOE Nuclear Facilities  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order defines the safety management program required by 10 CFR 830.204(b)(5) for maintenance and the reliable performance of Structures, Systems and Components (SSCs) that are part of the safety basis required by 10 CFR 830.202.1 at hazard category 1, 2 and 3 Department of Energy (DOE) nuclear facilities. Cancels DOE O 433.1. Canceled by DOE O 433.1B.

2007-02-13T23:59:59.000Z

294

Maintenance Management Program for DOE Nuclear Facilities  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The order defines the safety management program required by 10 CFR 830.204(b)(5) for maintenance and the reliable performance of structures, systems and components that are part of the safety basis required by 10 CFR 830.202 at hazard category 1, 2 and 3 DOE nuclear facilities. Cancels DOE O 433.1A. Admin Chg 1, dated 3-12-2013, cancels DOE O 433.1B.

2010-04-21T23:59:59.000Z

295

Notice of Intent to Revise DOE O 457.1, Nuclear Counterterrorism  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

Intent is to revise DOE O 457.1 and include the content of DOE M 457.1-1 as appendices to the revised order.

2013-02-07T23:59:59.000Z

296

To: Joel Rubin/EE/DOE@DOE  

Broader source: Energy.gov (indexed) [DOE]

'J| 'J| MaryBeth Zinmerman 0212212001 10:37 AM ',U To: Joel Rubin/EE/DOE@DOE cc: Nancy Jeffery/EE/DOE@DOE Subject: Old Chpt 2, new Chap 3 Can you work on answering the editor's questions on this? Forwarded by MaryBeth Zimmenman/EE/DOE on 22/2001 10:36 AM "'"- . . Michael York 02/21/2001 01:13 PM To: commcoll@aol.com cc: MaryBeth Zimmerman/EE/DOE@DOE Subject: Chapter 2 Joan, attached is the first chapter to edit. We will be sending you the next chapter as soon as it is available. If you have any questions, please call me at (202) 586-5669. Thanks! Michael York Chapter 2_Energy Impacts_2.16.01.d 22894 DOE024-0300 JOEL RUBIN 02/22/2001 03:00 PM To: Marybeth Zimmerman cc: Nancy Jeffery, Darrell Beschen/EE/DOE@DOE, Michael York Subject Chapter 2 Updates MBZ - This draft incorporates (in blue ink) updates based upon the comments from Joan. Ive deleted Joan's

297

Sanyo Electric: Order (2010-CE-1210) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Sanyo Electric: Order (2010-CE-1210) Sanyo Electric: Order (2010-CE-1210) October 13, 2010 DOE issued an Order and entered into a Compromise Agreement with Sanyo E&E Corp. after...

298

POLICY GUIDANCE MEMORANDUM #33- Requirements for DOE Delegated Examining Procedures  

Broader source: Energy.gov [DOE]

The purpose of this guidance is to establish the Department of Energys (DOEs) Delegated Examining policy and procedures in order to ensure an effective competitive examining program that supports...

299

DOE-HDBK-1046-2008 | Department of Energy  

Office of Environmental Management (EM)

DOE-HDBK-1046-2008 DOE-HDBK-1046-2008 August 21, 2008 Temporary Emergency Exposure Limits for Chemicals: Methods and Practice This order, and its Guides issued in 2007, reference...

300

DOE-STD-1040-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

for, Control of On-Shift Training, Chapter V of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. "Control of On-Shift Training" is...

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Midea: Order (2013-SE-1505)  

Broader source: Energy.gov [DOE]

DOE ordered GD Midea Air-Conditioning Equipment Co. Ltd. to pay a $416,800 civil penalty after finding Midea had manufactured and distributed in commerce in the U.S. atleast 14,968 units of basic model MWJ1-08ERN1-BI8, a noncompliant room air conditioner.

302

Versonel: Order (2014-CE-21009)  

Broader source: Energy.gov [DOE]

DOE ordered Smart Surplus, Inc. d/b/a Versonel to pay a $8,000 civil penalty after finding Versonel had failed to certify that certain models of refrigerators and residential clothes dryers comply with the applicable energy conservation standards.

303

Bigwall: Order (2014-SE-15006)  

Broader source: Energy.gov [DOE]

DOE ordered Bigwall Enterprises, Inc. to abide by the terms of the Notice of Noncompliance Determination, issued on February 11, 2014, after finding Bigwall Enterprises, Inc. had privately labeled and distributed in commerce in the U.S. at least 600 units of PerfectAire brand room air conditioner model PACH8000.

304

LG: Order (2014-SE-15011)  

Broader source: Energy.gov [DOE]

DOE ordered LG Electronics USA, Inc. to pay a $1,479,860 civil penalty after finding LG had manufactured and distributed in commerce in the U.S. at least 7,438 units of basic model LT143CNR, a noncompliant room air conditioner.

305

News & Updates - DOE Directives, Delegations, and Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Cancellation of Directives Document Actions NEW - DOE O 422.1 Admin Chg 2, Conduct of Operations by Diane Johnson The objective of this Order is to define the requirements for...

306

DOE-STD-1128-98; Changes to DOE-STD-1128-98, "Guide for Occupational Radiological Protection in Plutonium Facilities"  

Broader source: Energy.gov (indexed) [DOE]

Changes to DOE-STD-1128-98, "Guide for Occupational Radiological Protection in Plutonium Changes to DOE-STD-1128-98, "Guide for Occupational Radiological Protection in Plutonium Facilities Section/Page Change Cover Change "Metric" to "Not Measurement Sensitive". Throughout the document Change "the DOE Radiological Control Manual (RCM)" to "the DOE standard DOE- STD-1098-99, Radiological Control (RCS)". Change "RCM" to "RCS". Replace (DOE, 1993c) with (DOE, 1998a). Replace (DOE, 19941) with (DOE, 1999b). Delete reference to DOE Order 5700C, Quality Assurance. Replace ANSI N13.6-1989 (ANSI, 1996) with ANSI/HPS N13.6 (ANSI, 1999a). Change "ANSI N323-1993 (ANSI, 1993)" to "ANSI N323a (ANSI, 1997b)". Change "DOE Order 420.1 (DOE, 1995c)" to "Order 420.1A (DOE, 2002a)".

307

DOE Awards Management and Operating Contract for DOE's Strategic...  

Energy Savers [EERE]

DOE Awards Management and Operating Contract for DOE's Strategic Petroleum Reserve DOE Awards Management and Operating Contract for DOE's Strategic Petroleum Reserve September 18,...

308

Page not found | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

81 - 27590 of 29,416 results. 81 - 27590 of 29,416 results. Download AeroSys: Noncompliance Determination (2010-CE-01/0201 and 2010-SE-0302) DOE issued a Notice of Noncompliance Determination to AeroSys, Inc. finding that basic models THDC-18S, THDC-18T, THDC-24S, and THDC-24T do not comport with the energy conservation standards. http://energy.gov/gc/downloads/aerosys-noncompliance-determination-2010-ce-010201-and-2010-se-0302 Download Watermark: Noncompliance Determination (2011-SW-2908) DOE issued a Notice of Noncompliance Determination to Watermark Designs, Ltd. finding that model SH-FAL-90, a showerhead, does not comport with the water conservation standards. http://energy.gov/gc/downloads/watermark-noncompliance-determination-2011-sw-2908 Download Felix Storch: Noncompliance Determination (2011-SE-1420)

309

DOE Lessons Learned  

Broader source: Energy.gov [DOE]

DOE Lessons Learned Information Services Catches the Eye of Corporations and Educational Institutions

310

DOE Approved Technical Standards  

Broader source: Energy.gov [DOE]

The DOE Technical Standards Program promotes the use of voluntary consensus standards at DOE, manages and facilitates DOE's efforts to develop and maintain necessary technical standards, and communicates information on technical standards activities to people who develop or use technical standards in DOE.

311

DOE International Energy Advisors  

Broader source: Energy.gov [DOE]

DOEs Office of Electricity Delivery and Energy Reliability's (OE) Infrastructure Security and Energy Restoration Division (ISER) has coordinated and executed interagency support agreements with five of the geographic Combatant Commands to assign a DOE representative a DOE Energy Advisor to each of their headquarters.

312

DOE-FLEX: DOE's Telework Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The directive establishes the requirements and responsibilities for the Departments telework program. Canceled by DOE O 314.1.

2011-07-05T23:59:59.000Z

313

Approved DOE Technical Standards  

Broader source: Energy.gov (indexed) [DOE]

approved-doe-technical-standards Forrestal Building approved-doe-technical-standards Forrestal Building 1000 Independence Avenue, SW Washington, DC 205851.800.dial.DOE en DOE-STD-1150-2013 http://energy.gov/hss/downloads/doe-std-1150-2013 doe-std-1150-2013" class="title-link">DOE-STD-1150-2013

314

DOE-TSPP-10, Conversion of DOE Technical Standards to Non-Government  

Broader source: Energy.gov (indexed) [DOE]

July 1, 2009 July 1, 2009 DOE-TSPP-10, Conversion of DOE Technical Standards to Non-Government Standards - July 1, 2009 Technical Standards Program Procedures (TSPP) - August 26, 2009 This procedure provides guidance on the conversion of DOE Technical Standards to Voluntary Consensus Standards (VCSs), also referred to as non-Government standards. This procedure applies to all DOE Headquarters and field organizations, management and operating contractors, and laboratories (hereafter referred to collectively as "DOE Components") working to the requirements of the latest revision of DOE Order 252.1, "Technical Standards Program." DOE-TSPP-10, Conversion of DOE Technical Standards to Non-Government Standards - July 1, 2009 More Documents & Publications

315

DOE-HDBK-1078-94; DOE Handbook Training Program Handbook: A Systematic Approach to Training  

Broader source: Energy.gov (indexed) [DOE]

MEASUREMENT MEASUREMENT SENSITIVE DOE-HDBK-1078-94 August 1994 Supercedes DOE-STD-0102T, TAP-2 DOE HANDBOOK TRAINING PROGRAM HANDBOOK: A SYSTEMATIC APPROACH TO TRAINING U.S. Department of Energy FSC 6910 Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615)576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703)487-4650. Order No. DE94018722 DOE-HDBK-1078-94 iii FOREWORD This Department of Energy (DOE) Handbook, DOE-HDBK-1078-94, Training Program

316

Consent Order, Battelle Memorial Institute WCO-2014-01  

Broader source: Energy.gov [DOE]

Worker Safety and Health Enforcement Consent Order issued to Battelle Memorial Institute for deficiencies associated with the Chronic Beryllium Disease Prevention Program at DOEs Pacific Northwest National Laboratory.

317

DOE-STD-1021-93  

Broader source: Energy.gov [DOE]

Natural Phenomena Hazards Performance Categorization Guidelines for Structures, Systems, and Components Replaced by DOE-STD-1020-2012 | Change Notice No. 1 (January 1996) | Reaffirmed with Errata (April 2002) The purpose of this standard is as follows: (a) To provide, for the purpose of Natural Phenomena Hazard (NPH) design and evaluation, criteria for selecting performance categories (PCs) of structures, systems, and components (SSCs) in accordance with the requirements specified in DOE Order 420.1 (Reference 10) and the NPH Guide to DOE O 420.1 (DOE G 420.1-2) (Reference 11).

318

DOE-STD-1020-2012  

Broader source: Energy.gov [DOE]

Natural Phenomena Hazards Analysis and Design Criteria for Department of Energy Facilities Supersedes DOE-STD-1020-2002 This Department of Energy (DOE) Standard (STD)-1020-2012, Natural Phenomena Hazards Analysis and Design Criteria for DOE Facilities, provides criteria and guidance for the analysis and design of facility structures, systems, and components (SSCs) that are necessary to implement the requirements of DOE Order (O) 420.1C, Facility Safety, and to ensure that the SSCs will be able to effectively perform their intended safety functions under the effects of natural phenomena hazards (NPHs).

319

DOE Standard: Fire protection design criteria  

SciTech Connect (OSTI)

The development of this Standard reflects the fact that national consensus standards and other design criteria do not comprehensively or, in some cases, adequately address fire protection issues at DOE facilities. This Standard provides supplemental fire protection guidance applicable to the design and construction of DOE facilities and site features (such as water distribution systems) that are also provided for fire protection. It is intended to be used in conjunction with the applicable building code, National Fire Protection Association (NFPA) Codes and Standards, and any other applicable DOE construction criteria. This Standard replaces certain mandatory fire protection requirements that were formerly in DOE 5480.7A, ``Fire Protection``, and DOE 6430.1A, ``General Design Criteria``. It also contains the fire protection guidelines from two (now canceled) draft standards: ``Glove Box Fire Protection`` and ``Filter Plenum Fire Protection``. (Note: This Standard does not supersede the requirements of DOE 5480.7A and DOE 6430.1A where these DOE Orders are currently applicable under existing contracts.) This Standard, along with the criteria delineated in Section 3, constitutes the basic criteria for satisfying DOE fire and life safety objectives for the design and construction or renovation of DOE facilities.

Not Available

1999-07-01T23:59:59.000Z

320

Administrative Order, June 13, 2000 Summary  

Broader source: Energy.gov (indexed) [DOE]

Administrative Order No. 00NWPKW-1251 Administrative Order No. 00NWPKW-1251 State Washington Agreement Type Administrative Order Legal Driver(s) RCRA Scope Summary Resolve Ecology's October 12, 1999 finding that DOE failed to complete Major TPA Milestone M-32 with respect to Double-Shell Tank (DST) integrity assessments Parties DOE; CH2M Hill Hanford Group; State of Washington Department of Ecology Date 6/13/2000 SCOPE * Require DOE and CH2M Hill Hanford Group to comply with the Revised Code of Washington, HWMA, Washington Administrative Code, the Dangerous Waste Regulations, and by reference, the CFR by taking actions which are described in this Order. * Resolve Ecology's October 12, 1999 finding that DOE failed to complete Major TPA Milestone M-32 with respect to Double-Shell Tank (DST) integrity assessments.

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Cal Flame: Order (2015-CE-14015)  

Broader source: Energy.gov [DOE]

DOE ordered Cal Flame to pay a $8,000 civil penalty after finding Cal Flame had failed to certify that refrigerator basic model BBQ09849P-H complies with the applicable energy conservation standards.

322

Bull Outdoor Products: Order (2015-CE-14014)  

Broader source: Energy.gov [DOE]

DOE ordered Bull Outdoor Products, Inc. to pay a $8,000 civil penalty after finding Bull had failed to certify that refrigerator basic model BC-130 complies with the applicable energy conservation standards.

323

Mackle Company: Order (2010-SE-0106)  

Broader source: Energy.gov [DOE]

DOE ordered Mackle Company, Inc. to pay a $27,200 civil penalty after finding the company had failed to certify that a variety of refrigerators, refrigerator-freezers, and freezers comply with the applicable energy conservation standards.

324

Minka-Aire: Order (2014-CE-32018)  

Broader source: Energy.gov [DOE]

DOE ordered Minka Lighting Inc. to pay a $8,000 civil penalty after finding Minka had failed to certify that certain models of ceiling fans comply with the applicable energy conservation standards.

325

Cospolich Refrigerator: Order (2013-CE-5314)  

Broader source: Energy.gov [DOE]

DOE ordered Cospolich Refrigerator Co, Inc. to pay a $8,000 civil penalty after finding Cospolich Refrigerator had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

326

Refrigerator Manufacturers: Order (2013-CE-5341)  

Broader source: Energy.gov [DOE]

DOE ordered Refrigerator Manufacturers, LLC to pay a $8,000 civil penalty after finding Refrigerator Manufacturers had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

327

International Refrigeration: Order (2012-CE-1510)  

Broader source: Energy.gov [DOE]

DOE ordered International Refrigeration Products to pay an $8,000 civil penalty after finding International Refrigeration had failed to certify that certain room air conditioners comply with the applicable energy conservation standard.

328

Jandy Pool Products: Order (2010-CE-1111)  

Broader source: Energy.gov [DOE]

DOE ordered Jandy Pool Products, Inc. to pay a $10,000 civil penalty after finding Jandy Pool Products had failed to certify that certain models of pool heaters comply with the applicable energy conservation standards.

329

Anthony International: Order (2013-CE-5357)  

Broader source: Energy.gov [DOE]

DOE ordered Anthony International to pay a $8,000 civil penalty after finding Anthony International had failed to certify that any basic models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

330

Polar King: Order (2013-CE-5328)  

Broader source: Energy.gov [DOE]

DOE ordered Polar King International Inc. to pay a $8,000 civil penalty after finding Polar King had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

331

Euro Chef USA: Order (2014-CE-23004)  

Broader source: Energy.gov [DOE]

DOE ordered Euro Chef USA Inc. to pay a $8,000 civil penalty after finding Euro Chef USA had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

332

Danby Products: Order (2012-CE-1415)  

Broader source: Energy.gov [DOE]

DOE ordered Danby Products to pay a $9,900 civil penalty after finding Danby had failed to certify that certain models of refrigerators and freezers comply with the applicable energy conservation standard.

333

Barclay Products: Order (2013-CW-3005)  

Broader source: Energy.gov [DOE]

DOE ordered Barclay Products, Ltd. to pay a $8,000 civil penalty after finding Barclay Products had failed to certify that certain models of water closets comply with the applicable water conservation standards.

334

Minibar North America: Order (2014-CE-14010)  

Broader source: Energy.gov [DOE]

DOE ordered Minibar North America, Inc. to pay a $8,000 civil penalty after finding Minibar had failed to certify that certain models of refrigerators comply with the applicable energy conservation standards.

335

Commercial Cooler: Order (2013-CE-5343)  

Broader source: Energy.gov [DOE]

DOE ordered Commercial Cooler, Inc. to pay a $8,000 civil penalty after finding Commercial Cooler had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

336

Southeast Cooler: Order (2013-CE-5331)  

Broader source: Energy.gov [DOE]

DOE ordered Southeast Cooler Corp. to pay a $8,000 civil penalty after finding Southeast Cooler had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

337

Golden Cooler: Order (2013-CE-5345)  

Broader source: Energy.gov [DOE]

DOE ordered Golden Cooler to pay a $8,000 civil penalty after finding Golden Cooler had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

338

Custom Coolers: Order (2013-CE-5315)  

Broader source: Energy.gov [DOE]

DOE ordered Custom Coolers, LLC to pay a $8,000 civil penalty after finding Custom Coolers had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

339

Topstar International: Order (2011-CE-2703)  

Broader source: Energy.gov [DOE]

DOE ordered Topstar International, Inc. to pay a $6,000 civil penalty after finding Topstar International had failed to certify that certain models of incandescent reflector lamps comply with the applicable energy conservation standards.

340

EiKO: Order (2011-CE-2702)  

Broader source: Energy.gov [DOE]

DOE ordered EiKO Ltd. - North America to pay a $6,000 civil penalty after finding EiKO had failed to certify that certain models of incandescent reflector lamps comply with the applicable energy conservation standards.

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Duro Corporation: Order (2014-CE-23009)  

Broader source: Energy.gov [DOE]

DOE ordered Duro Corporation to pay a $8,000 civil penalty after finding Duro Corporation had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

342

National Comfort Products: Order (2014-SE-16014)  

Broader source: Energy.gov [DOE]

DOE ordered National Comfort Products to pay a $16,000 civil penalty after finding National Comfort Products had failed to certify that certain models of central air conditioners and heat pumps comply with the applicable energy conservation standards.

343

Fisher & Paykel: Order (2014-CE-23012)  

Broader source: Energy.gov [DOE]

DOE ordered Fisher & Paykel Appliances, Inc. to pay a $8,000 civil penalty after finding Fisher & Paykel had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

344

Viking Range: Order (2014-CE-23014)  

Broader source: Energy.gov [DOE]

DOE ordered Viking Range, LLC to pay a $8,000 civil penalty after finding Viking Range had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

345

American Range: Order (2014-CE-23006)  

Broader source: Energy.gov [DOE]

DOE ordered American Range Corporation to pay a $8,000 civil penalty after finding American Range had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

346

Peerless-Premier: Order (2014-CE-23007)  

Broader source: Energy.gov [DOE]

DOE ordered Peerless-Premier Appliance Co. to pay a $8,000 civil penalty after finding Peerless-Premier had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

347

Nostalgia Products: Order (2014-CE-14017)  

Broader source: Energy.gov [DOE]

DOE ordered Nostalgia Products Group, LLC to pay a $8,000 civil penalty after finding Nostalgia Products had failed to certify that certain models of refrigerators and refrigerator-freezers comply with the applicable energy conservation standards.

348

Purcell-Murray: Order (2014-CE-23019)  

Broader source: Energy.gov [DOE]

DOE ordered Purcell-Murray Company, Inc. to pay a $8,000 civil penalty after finding Purcell-Murray had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

349

Distinctive Appliances: Order (2014-CE-23020)  

Broader source: Energy.gov [DOE]

DOE ordered Distinctive Appliances Distributing, Inc. to pay a $8,000 civil penalty after finding Distinctive Appliances had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

350

BSH Home Appliances: Order (2014-CE-23013)  

Broader source: Energy.gov [DOE]

DOE ordered BSH Home Appliances Corporation to pay a $12,000 civil penalty after finding BSH Home Appliances had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

351

Capital Cooking: Order (2014-CE-23008)  

Broader source: Energy.gov [DOE]

DOE ordered Capital Cooking Equipment, Inc. to pay a $8,000 civil penalty after finding Capital Cooking had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

352

MC Appliance: Order (2014-CE-20002)  

Broader source: Energy.gov [DOE]

DOE ordered MC Appliance Corporation to pay a $16,000 civil penalty after finding MC Appliance had failed to certify that certain models of residential clothes washers and residential clothes dryers comply with the applicable energy conservation standards.

353

Prizer-Painter: Order (2014-CE-23005)  

Broader source: Energy.gov [DOE]

DOE ordered Prizer-Painter Stove Works, Inc. to pay a $8,000 civil penalty after finding Prizer-Painter had failed to certify that certain models of cooking products comply with the applicable energy conservation standards.

354

Fagor America: Order (2013-CEW-19001)  

Broader source: Energy.gov [DOE]

DOE ordered Fagor America, Inc. to pay a $13,000 civil penalty after finding Fagor America had failed to certify that certain models of residential refrigerator-freezers and dishwashers comply with the applicable energy and water conservation standards.

355

American Valve: Order (2010-CW-1411)  

Broader source: Energy.gov [DOE]

DOE ordered American Valve, Inc. to pay a $5,000 civil penalty after finding American Valve had failed to certify that certain showerhead models comply with the applicable water conservation standards.

356

Hisense USA: Order (2010-CE-1211)  

Broader source: Energy.gov [DOE]

DOE issued an Order after entering into a Compromise Agreement with Hisense USA Corp. after finding Hisense USA had failed to certify that certain models of residential refrigerators, refrigerator-freezers, and freezers comply with the applicable energy conservation standards.

357

DOE-STD-1107-97; DOE Standard Knowledge, Skills, and Abilities For Key Radiation Protection Positions at DOE Facilities  

Broader source: Energy.gov (indexed) [DOE]

STANDARD STANDARD KNOWLEDGE, SKILLS, AND ABILITIES FOR KEY RADIATION PROTECTION POSITIONS AT DOE FACILITIES U.S. Department of Energy FSC 6910 Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. DOE-STD-1107-97 January 1997 Reaffirmed June 2005 This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE97003656 Reaffirmation with Errata DOE-HDBK-1107-97 Knowledge, Skills, and Abilities for Key Radiation Protection Positions at DOE

358

DOE-STD-1065-94; DOE Standard Guideline to Good Practices For Postmaintenance Testing at DOE Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

65-94 65-94 June 1994 DOE STANDARD GUIDELINE TO GOOD PRACTICES FOR POSTMAINTENANCE TESTING AT DOE NUCLEAR FACILITIES U.S. Department of Energy AREA MNTY Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE94014953 DOE-STD-1065-94 FOREWORD The purpose of the Guide to Good Practices for Postm aintenance T esting at DOE Nuclear Facilities is to provide contractor maintenance

359

DOE-STD-1068-94; DOE Standard Guideline to Good Practices For Maintenance History at DOE Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

8-94 8-94 June 1994 DOE STANDARD GUIDELINE TO GOOD PRACTICES FOR MAINTENANCE HISTORY AT DOE NUCLEAR FACILITIES U.S. Department of Energy AREA MNTY Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE94014950 DOE-STD-1068-94 FOREW ORD The purpose of the Guideline to Good Practices for Maintenance History at DOE Nuclear Facilities is to provide contractor maintenance organizations with information

360

DOE-STD-1055-93; DOE Standard Guideline to Good Practices For Maintenance Management Involvement at DOE Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

NOT MEASUREMENT NOT MEASUREMENT SENSITIVE SENSITIVE DOE-STD-1055-93 March 1993 DOE STANDARD GUIDELINE TO GOOD PRACTICES FOR MAINTENANCE MANAGEMENT INVOLVEMENT AT DOE NUCLEAR FACILITIES U.S. Department of Energy AREA MNTY Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831. Available to the public from the National Technical Information Service, U.S. Department of Commerce, 5285 Port Royal Rd., Springfield, VA 22161. Order No. DE93013953 DOE-STD-1055-93 FOREWORD The purpose of the Guideline to Good Practices for M

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

DOE-STD-1064-94; DOE Standard Guideline to Good Practices For Seasonal Facility Preservation at DOE Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

64-94 64-94 June 1994 DOE STANDARD GUIDELINE TO GOOD PRACTICES FOR SEASONAL FACILITY PRESERVATION AT DOE NUCLEAR FACILITIES U.S. Department of Energy Washington, D.C. 20585 AREA MNTY DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield VA 22161; (703) 487-4650. Order No. DE94014954 DOE-STD-1064-94 FOREWORD The Guideline to Good Practices for Seasonal Facility Preservation at DOE Nuclear Facilities provides contractor maintenance organizations with information

362

Consent Order 2005-01  

Broader source: Energy.gov [DOE]

The Department of Energy (DOE) has reviewed Bechtel Hanford, Inc.s (Bechtel Hanford) investigation and supporting documentation associated with two events occurring at the 618-2 Burial Ground in December 2004. These events resulted in significant personnel uptakes to two individuals. Bechtel Hanford reported these events using the Noncompliance Tracking System (NTS) on January 26, 2005, (NTS-RL-BHIREMACT- 2005-0001, Hazard Identification and Personnel Exposure at 618-2 Historical Burial Site). By letter dated May 24, 2005, Bechtel Hanford requested DOE consideration for a Consent Order (in lieu of an Enforcement Action) with respect to the two events.

363

Nuclear Explosive and Weapon Surety Program - DOE Directives...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Order provides requirements and responsibilities to prevent unintendedunauthorized detonation and deliberate unauthorized use of nuclear explosives. Cancels DOE O 452.1B....

364

Nuclear Explosive and Weapon Surety Program - DOE Directives...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Order provides requirements and responsibilities to prevent unintendedunauthorized detonation and deliberate unauthorized use of nuclear explosives. Cancels DOE O 452.1. Canceled...

365

Nuclear Explosive and Weapon Surety Program - DOE Directives...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Order provides requirements and responsibilities to prevent unintendedunauthorized detonation and deliberate unauthorized use of nuclear explosives. Cancels DOE O 452.1A....

366

DOE-STD-1073-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Management Implementation, 101398 CRAD, Engineering - Office of River Protection K Basin Sludge Waste System Order Module--DOE-STD-1073-2003, CONFIGURATION MANAGEMENT...

367

Microsoft Word - DOE News Release - Energy Department Selects...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Contractor for Paducah Gaseous Diffusion Plant LEXINGTON, Ky. - The U.S. Department of Energy (DOE) today awarded a Task Order under the Nationwide Environmental Management ID...

368

News Archive | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

October 13, 2009 October 13, 2009 Department of Energy Announces Steps to Strengthen Enforcement of Energy Efficiency Standards Steps will help ensure that manufacturers have a level playing field September 24, 2009 Department of Energy Announces Testing for AeroSys, Inc. Products to Ensure Compliance with Appliance Standards Washington, DC - As part of its renewed efforts to ensure compliance with national energy efficiency appliance standards, the U.S. Department of Energy today issued a test notice requiring AeroSys, Inc. July 24, 2009 Department of Energy Subpoenas Compliance Data from AeroSys, Inc. DOE General Counsel Announces Renewed Focus on Enforcing Efficiency Standards March 18, 2009 DOE General Counsel Nomination Announcement WASHINGTON, DC - Today, President Barack Obama announced his intent to

369

DOE Laboratory Accreditation Program  

Broader source: Energy.gov [DOE]

Administered by the HSS Office of Corporate Safety Programs, the DOE Laboratory Accreditation Program (DOELAP) is responsible for implementing performance standards for DOE contractor external dosimetry and radiobioassay programs through periodic performance testing and on-site program assessments.

370

Approved DOE Technical Standards  

Office of Environmental Management (EM)

ehss908241 Approved DOE Technical Standards en DOE-STD-3009-2014 http:energy.govehssdownloadsdoe-std-3009-2014

371

2012 DOE Sustainability Awards  

Broader source: Energy.gov [DOE]

In 2012, DOE Sustainability Awards recognized 20 teams and individuals representing DOE national laboratories for their outstanding sustainability contributions, including accomplishments in managing pollution, waste, energy, water, and vehicle fleets.

372

Completed DOE Technical Standards  

Broader source: Energy.gov (indexed) [DOE]

Completed) Completed) Project Number Title Document ID SLM / ORG Author / Phone / Email Status / Review Date P1020-2002REV National Phenomena hazards Design and Evaluation Criteria for DOE Facilities DOE-STD-1020-2012 James O'Brien (HS-30) P1066-1999REV Fire Protection and Emergency Services Program and Design Criteria (revision to DOE-STD-1066-99) DOE-STD-1066-2012 James O'Brien (HS-30)

373

Extension of DOE Directives  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Notice extends the following directives until 2/16/04: DOE N 205.2, Foreign National Access to DOE Cyber Systems, and DOE N 205.3, Password Generation, Protection, and Use, dated 11/23/99-7/1/00.

2003-02-24T23:59:59.000Z

374

EFCOG / DOE Electrical Safety  

E-Print Network [OSTI]

of electrical hazards used in the DOE Electrical Safety Handbook and laboratory programs. Thus, portionsEFCOG / DOE Electrical Safety Improvement Project Project Area 4 ­Performance Measurement personnel. This tool is also intended to assist DOE organizations in determining and classifying ORPS

375

DOE HANDBOOK ELECTRICAL SAFETY  

E-Print Network [OSTI]

DOE HANDBOOK ELECTRICAL SAFETY U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. DOE-HDBK-1092 and others guidance for the "Analyze the Hazard" step of DOE's Integrated Safety Management (ISM

376

Object-Parallel Infrastructure for Implementing First-Order Methods ...  

E-Print Network [OSTI]

Jan 22, 2015 ... By first-order algorithms, we mean methods whose ..... However, such compilers do not presently exist, nor even does an active, accepted...

2015-01-22T23:59:59.000Z

377

DOE Science Showcase - Cool roofs, cool research, at DOE | OSTI, US Dept of  

Office of Scientific and Technical Information (OSTI)

Cool roofs, cool research, at DOE Cool roofs, cool research, at DOE Science Accelerator returns cool roof documents from 6 DOE Databases Executive Order on Sustainability Secretary Chu Announces Steps to Implement One Cool Roof Cool Roofs Lead to Cooler Cities Guidelines for Selecting Cool Roofs DOE Cool Roof Calculator Visit the Science Showcase homepage. OSTI Homepage Mobile Gallery Subscribe to RSS OSTI Blog Get Widgets Get Alert Services OSTI Facebook OSTI Twitter OSTI Google+ Bookmark and Share (Link will open in a new window) Go to Videos Loading... Stop news scroll Most Visited Adopt-A-Doc DOE Data Explorer DOE Green Energy DOepatents DOE R&D Accomplishments .EDUconnections Energy Science and Technology Software Center E-print Network National Library of Energy OSTIblog Science.gov Science Accelerator

378

NEW - DOE O 422.1 Admin Chg 2, Conduct of Operations - DOE Directives...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

NEW - DOE O 422.1 Admin Chg 2, Conduct of Operations by Diane Johnson The objective of this Order is to define the requirements for establishing and implementing Conduct of...

379

American Power: Order (2010-CE-0911) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Power: Order (2010-CE-0911) Power: Order (2010-CE-0911) American Power: Order (2010-CE-0911) October 5, 2010 DOE issued an Order and entered into a Compromise Agreement with American Power Solutions, Inc. American Power had not certified compliance with the energy conservation standards for a general service flurorescent lamp it advertised on its website as manufactured by American Power. American Power notified DOE that it does not manufacture, import, or private label this model, but instead purchases it from GE and MaxLite. The Order adopted a Compromise Agreement, which reflected settlement terms between DOE and American Power. American Power: Order (2010-CE-0911) More Documents & Publications Westinghouse Lighting: Order (2010-CE-09/1001) Philips: Order (2012-SE-2605) Simkar: Order (2012-SE-5408)

380

DOE-STD-1107-97 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

7-97 7-97 DOE-STD-1107-97 November 08,2007 DOE-STD-1107-97: Knowledge, Skills, and Abilities for Key Radiation Protection Positions at DOE Facilities Change Notice No. 1 (November 2007) This document provides detailed qualification criteria for contractor key radiation protection personnel. Although federal key radiation protection positions are also identified in Table 1, qualification standards for federal positions are provided in DOE O 360.1B, October 2001 and the DOE Technical Qualifications Program. DOE-STD-1107-97: Knowledge, Skills, and Abilities for Key Radiation Protection Positions at DOE Facilities More Documents & Publications DOE-STD-1107-97 Technical Standards, DOE Orders and Applicable CFRs/DEAR Crosswalk - February 2, 2002 Technical Standards,DOE Standards and Corresponding Directives Crosswalk -

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

DOE-TSL-2-2002 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

2-2002 2-2002 DOE-TSL-2-2002 September 24, 2002 Directory of Points of Contact for the DOE Technical Standards Program Replaced by DOE-TSL-2-2006 | Supersedes DOE-TSL-2-98 (January 1998) This TSL supplements DOE manuals, directives, orders, and standards. It provides basic and fundamental information for DOE Component personnel involved in identifying standardization documents. It also provides listings of points of contact within DOE and identifies links to points of contact within the Department of Defense (DoD) for coordination of standardization activities. DOE-TSL-2-2002, Directory of Points of Contact for the DOE Technical Standards Program More Documents & Publications Technical Standards, Newsletter-June 1997 DOE-TSL-1-2002 Diversity Employment and Recruitment Sources

382

Electrolux: Order (2012-CE-1901)  

Broader source: Energy.gov (indexed) [DOE]

Electrolux North America, Electrolux North America, Respondent Issued: July 27, 2012 ) ) ) ) ) ORDER Case Number: 2012-CE-1901 By the General Counsel, U.S. Department of Energy: 1. In this Order, I adopt the attached Compromise Agreement entered into between the U.S. Department of Energy ("DOE") and Electrolux North America ("Respondent"). The Compromise Agreement resolves the case initiated to pursue a civil penalty for violations of the compliance certification requirements located at 10 C.F.R. § 429.12. 2. DOE and Respondent have negotiated the terms of the Compromise Agreement that resolves this matter. A copy of the Compromise Agreement is attached hereto and incorporated by reference. 3. After reviewing the terms of the Compromise Agreement and evaluating the facts

383

Sunpentown: Order (2012-CE-1505)  

Broader source: Energy.gov (indexed) [DOE]

BEFORETHE BEFORETHE U.S. DEPARTMENT OF ENERGY WASHINGTON, D.C. 20585 In the Matter of: Sunpcntown International Inc. Respondent Issued: August 2, 2012 ) ) ) ) ) ) ORDER Case Number: 2012-CE-1505 By the General Counsel, U.S. Department of Energy: I. In this Order, I adopt the attached Compromise Agreement entered into between the U.S. Department of Energy ("DOE") and Sunpentown Intemational Inc. ("Respondent"). The Compromise Agreement resolves the case initiated to pursue a civil penalty for violations of the compliance certification requirements located at 10 C.P.R. § 429.12. 2. The DOE and Respondent have negotiated the terms of the Compromise Agreement that resolve this matter. A copy of the Compromise Agreement is attached hereto and

384

DOE ISM CHAMPIONS  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

9/27/12 9/27/12 DOE ISM CHAMPIONS Organization Points of Contact Phone E-mail DOE ISM Co- Champion (HSS) Pat Worthington (301) 903-5926 pat.worthington@hq.doe.gov DOE ISM Co- Champion (EM) Ray Corey (509) 376-0108 ray_j_corey@rl.gov Ames Cindy Baebler (630) 252-1563 cynthia.baebler@ch.doe.gov Argonne Joanna M. Livengood (630) 252-2366 joanna.livengood@ch.doe.gov Brookhaven Bob Desmarais (631) 344-5434 rdesmarais@bnl.gov CBFO Josef A. Sobieraj (575) 234-7499 Josef.sobieraj@wipp.ws CDNS Don F. Nichols (202) 586-8216 don.nichols@nnsa.doe.gov Chicago Justin Zamirowski (630) 252-2248 justin.zamirowski@ch.doe.gov CNS-Energy Chip Lagdon (301) 903-4218 (202) 586-0799 chip.lagdon@hq.doe.gov EE Gary Staffo (202) 586-9577 gary.staffo@ee.doe.gov EM James A. Hutton (202) 586-0975 james.hutton@em.doe.gov

385

DOE Patents Database - FAQ's  

Office of Scientific and Technical Information (OSTI)

Frequently Asked Questions Frequently Asked Questions Why was this database developed and by whom? How is this collection different than the one at the United States Patent and Trademark Office? What are the criteria for including patent records in this collection? How do you determine these patents were sponsored by DOE? How many patents are in this collection? Does the collection include all of DOE's patents? Does this collection include the full text for each patent? What time frame is covered by DOepatents? How often is this collection and Web site updated? Does the U.S. Government have exclusive rights to these inventions? What is OSTI? Where can I find information about doing business with DOE? How can I find additional information on the patenting process? Where can I find patents that are not related to DOE?

386

DOE Information Center  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DOE Information Center DOE Information Center The U.S. Department of Energy (DOE) Information Center provides citizens a consolidated facility to obtain information and records related to the DOE's various programs in Oak Ridge and abroad. Employees at the DOE Information Center are available to assist with your requests and searches from 8:00 a.m. to 5:00 p.m. (EST), Monday through Friday, except for federal holidays. Requests Documents can be requested in person or by telephone, email, or fax. Reproduction Please allow DOE Information Center staff adequate time to reproduce documents. Some material requires special handling, security reviews, etc. Delivery Unless special arrangements have been made with DOE Information Center staff, documents should be picked up during normal business hours.

387

DOE Announces Publication of Three Reports by the DOE Electricity...  

Office of Environmental Management (EM)

Publication of Three Reports by the DOE Electricity Advisory Committee DOE Announces Publication of Three Reports by the DOE Electricity Advisory Committee January 15, 2009 -...

388

DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy...  

Broader source: Energy.gov (indexed) [DOE]

Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements March 16, 2010 - 4:28pm...

389

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) | Department of  

Broader source: Energy.gov (indexed) [DOE]

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) April 25, 2013 DOE ordered Duracold Refrigeration Manufacturing Company, LLC to pay a $8,000 civil penalty after finding Duracold Refrigeration Manufacturing had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards. The Order adopted a Compromise Agreement, which reflected settlement terms between DOE and Duracold Refrigeration Manufacturing. Duracold Refrigeration Manufacturing: Order (2013-CE-5342) More Documents & Publications Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) North Star Refrigerator: Order (2013-CE-5355) Schott Gemtron: Order (2013-CE-5358

390

DOE-STD-1072-94; DOE Standard Guideline to Good Practices for Facility Condition Inspections at DOE Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

2-94 2-94 June 1994 DOE STANDARD GUIDELINE TO GOOD PRACTICES FOR FACILITY CONDITION INSPECTIONS AT DOE NUCLEAR FACILITIES U.S. Department of Energy Washington, D.C. 20585 AREA MNTY DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE94014948 DOE-STD-1072-94 iii FOREWORD The purpose of the Guideline to Good Practices for Facility Condition Inspections

391

DOE-STD-1067; DOE Standard Guideline to Good Practices for Maintenance Facilities, Equipment, and Tools at DOE Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

7-94 7-94 June 1994 DOE STANDARD GUIDELINE TO GOOD PRACTICES FOR MAINTENANCE FACILITIES, EQUIPMENT, AND TOOLS AT DOE NUCLEAR FACILITIES U.S. Department of Energy AREA MNTY Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703)487-4650. Order No. DE94014952 DOE-STD-1067-94 FOREW ORD The Guideline to Good Practices for Maintenance Facilities, Equipment, and Tools at

392

DOE Order Self Study Modules - DOE G 450.4-1B Integrated Safety...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

and implemented. Controls may include site or facility commitments, such as conduct of operations and maintenance programs; worker safety programs; specified safety systems; or...

393

DOE Order Self Study Modules - DOE O 414.1D Quality Assurance...  

Office of Environmental Management (EM)

the core sampling truck, it was discovered that wiring from the portable 37.5 KVA transformer to the power supply leads coming from the transformer were improperly connected. It...

394

American Power: Order (2010-CE-0911) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

American Power: Order (2010-CE-0911) American Power: Order (2010-CE-0911) American Power: Order (2010-CE-0911) October 5, 2010 DOE issued an Order and entered into a Compromise Agreement with American Power Solutions, Inc. American Power had not certified compliance with the energy conservation standards for a general service flurorescent lamp it advertised on its website as manufactured by American Power. American Power notified DOE that it does not manufacture, import, or private label this model, but instead purchases it from GE and MaxLite. The Order adopted a Compromise Agreement, which reflected settlement terms between DOE and American Power. American Power: Order (2010-CE-0911) More Documents & Publications Westinghouse Lighting: Order (2010-CE-09/1001) Maxlite: Order (2010-CE-2701)

395

DOE-HDBK-1139/2-02  

Broader source: Energy.gov [DOE]

Chemical Manager Replaced by DOE-HDBK-1139/2-2006 Volume 2 presents a description of the chemical management practices as individually developed at several Department of Energy (DOE) facilities. These are formatted according to the order presented in Volume 1 of the Handbook, published by the Chemical Safety Topical Committee (CSTC) in November 2000. Electronic inventory tracking, automated Material Safety Data Sheet (MSDS) systems, and Hazard Communication training are common among all Sites.

396

Maintenance Management Program for DOE Nuclear Facilities  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The order defines the safety management program required by 10 CFR 830.204(b)(5) for maintenance and the reliable performance of structures, systems and components that are part of the safety basis required by 10 CFR 830.202 at hazard category 1, 2 and 3 DOE nuclear facilities. Admin Chg 1, dated 3-12-2013. Cancels DOE O 433.1A.

2010-04-21T23:59:59.000Z

397

Surveillance Guide - OPS 9.15 Timely Orders to Operators  

Broader source: Energy.gov (indexed) [DOE]

TIMELY ORDERS TO OPERATORS TIMELY ORDERS TO OPERATORS 1.0 Objective The objective of this surveillance is to evaluate the facility program and practices for timely orders to operators. This surveillance provides a basis for evaluating the effectiveness of the contractor's timely orders to operators program and for establishing compliance with DOE requirements. 2.0 References 2.1 DOE 5480.19, Conduct of Operations Requirements for DOE Facilities 2.2 DOE-STD-1034-93, Guide to Good Practices for Timely Orders to Operators 3.0 Requirements Implemented This surveillance is conducted to implement the requirements of DOE 5480.19, Attachment I, Chapter XV. 4.0 Surveillance Activities The Facility Representative reviews the facility index and file of orders to operators and observes operator activities to evaluate

398

DOE O 442.1A  

Broader source: Energy.gov (indexed) [DOE]

442.1A 442.1A 6-6-01 THIS PAGE IS TO REMAIN WITH DOE O 442.1A THIS PAGE TRANSMITS AN ADMINISTRATIVE CHANGE TO DOE O 442.1, DEPARTMENT OF ENERGY EMPLOYEE CONCERNS PROGRAM, DATED 2-1-99. THIS PAGE ALSO CANCELS DOE O 442.1 AND REISSUES IT AS DOE O 442.1A, DEPARTMENT OF ENERGY EMPLOYEE CONCERNS PROGRAM, DATED 6-6-01. THE ADMINISTRATIVE CHANGE THAT OCCURRED WAS TO BRING THIS DIRECTIVE INTO COMPLIANCE WITH THE NATIONAL NUCLEAR SECURITY ADMINISTRATION. Distribution: Initiated By: All Departmental Elements Office Economic Impact and Diversity Office of Employee Concerns DOE O 442.1A Approved: 6-6-01 U.S. Department of Energy ORDER Washington, D.C. SUBJECT: DEPARTMENT OF ENERGY EMPLOYEE CONCERNS PROGRAM 1. OBJECTIVE. As a service to all Departmental Elements, the following will be to establish a

399

DOE-STD-1136-2000  

Broader source: Energy.gov [DOE]

Guide of Good Practices for Occupational Radiological Protection in Uranium Facilities Change Notice 1 (October 2001) | Change Notice 2 (March 2001) | Change Notice 3 (December 2001) This Technical Standard (TS) provides operational guidance, practical lessons learned and experience gained, guides to good practice, and reference information on the safe handling of uranium. The TS provides information to assist uranium facilities in complying with Title 10 of the Code of Federal Regulations (CFR), Part 835, Occupational Radiation Protection (10 CFR 835) (DOE 1998a). This TS supplements the DOE G 441.1 series of Guides, DOE Orders, and DOE-STD-1098-99, Radiological Control (RCS) (DOE 1999a) and has as its sole purpose the protection of workers and the public from the hazards that are inherent in uranium storage, processing, and handling.

400

Subject: DOE PERSONAL PROPERTY FOREIGN TRANSACTIONS  

Broader source: Energy.gov (indexed) [DOE]

DOE PERSONAL PROPERTY FOREIGN TRANSACTIONS DOE PERSONAL PROPERTY FOREIGN TRANSACTIONS (Title Transfer, Loan, and Abandonment) References: Atomic Energy Act Sections 161g and 161j., Title 42 of the United States Code (U.S.C.) sections 2201g, and 22201j 42 U.S.C 16312 (Public Law 109-58, title IX, section 972, Aug. 8, 2005, 119 Stat. 899), 41 Code of Federal Regulations (CFR) 102-36.380-395, Federal Management Regulation (FMR) DOE Order 580.1, Department of Energy Personal Property Program 4.c(3) DOE Guide 580.1-1, Department of Energy Personal Property Management Guide Chapter 11.8 When is this Acquisition Letter (AL) Effective? This AL is effective immediately upon issuance. When Does This AL Expire? This AL remains in effect until superseded, or canceled. Guidance in this Acquisition Letter shall

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

DOE O 412.1  

Broader source: Energy.gov (indexed) [DOE]

All Departmental Elements Office of Field Management U.S. Department of Energy ORDER Washington, D.C. SUBJECT: WORK AUTHORIZATION SYSTEM 1. OBJECTIVES. To establish a work authorization and control process for work performed by designated management and operating (M&O), management and integrating (M&I), environmental restoration management contracts (ERMC) and other contracts determined by the Procurement Executive (hereafter referred to as M&O contractors). 2. CANCELLATION. DOE 5700.7C, WORK AUTHORIZATION SYSTEM, dated 5-18- 92. Cancellation of a directive does not, by itself, modify or otherwise affect any contractual obligation to comply with such a directive. Canceled directives that are incorporated by reference in a contract remain in effect until the contract is modified to

402

BEFORE THE. U.S. DEPARTMENT OF ENERGY  

Broader source: Energy.gov (indexed) [DOE]

THE. THE. U.S. DEPARTMENT OF ENERGY Washington, D.C. 20585 In the Matter of: AeroSys, Inc. Case Number: 201 l-SCE-1624 (central air conditioners and heat pumps) ) ) ) ) ) ) AMENDED NOTICE OF PROPOSED CIVIL PENALTY Date issued: September 30, 2013 Number of alleged violations: Maximum possible assessment: Proposed civil penalty: Summary 7,032 violations $ 1,406,400 $ 1,145,600 On February 15, 2013, the Office of the General Counsel of the U.S. Department of Energy ("DOE") issued a Notice of Proposed Civil Penalty alleging that AeroSys, Inc. ("AeroSys") had violated the Energy Policy and Conservation Act ("EPCA"), 42 U.S.C. § 6291 et seq., and 10 C.F.R. Parts 429 and 430. After further consideration of all of the evidence collected during

403

The politics of representation and the social order : in the War on Terror  

E-Print Network [OSTI]

and Meaning Meaning and knowledge systems are critical to social order, but what exactly is knowledge, how does

Chang, Gordon C.

2008-01-01T23:59:59.000Z

404

DOE Science Showcase - Featured Climate Change Research from DOE Databases  

Office of Scientific and Technical Information (OSTI)

Featured Climate Change Research from DOE Databases Featured Climate Change Research from DOE Databases Search Results from DOE Databases View research documents, citations, accomplishments, patents, and projects related to climate change, one of the primary scientific challenges addressed through the Incite Program. Climate Change Information Bridge Energy Citations Database DOE R&D Accomplishments Database DOE Data Explorer Climate Modeling Information Bridge Energy Citations Database DOE R&D Accomplishments Database DOE Data Explorer Ocean Turbulence and Climate Information Bridge Energy Citations Database DOE Accomplishments Database DOE Data Explorer Cloud Simulation and Models Information Bridge Energy Citations Database DOE Accomplishments Database DOE Data Explorer Global Warming Information Bridge Energy Citations Database

405

DOE Responses to DOE Challenge Home (formerly Builders Challenge...  

Broader source: Energy.gov (indexed) [DOE]

Energy. doeresponseschallengehomecomments.pdf More Documents & Publications Version Tracking Document for DOE Challenge Homes, National Program Requirements (Rev. 03) DOE...

406

JGI - DOE Mission Relevance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

User Programs User Programs Project Management Office Community Science Program Emerging Technologies Opportunity Program Technology Development Pilot Program Genomic Encyc. of Bacteria and Archaea MyJGI: Information for Collaborators DOE Mission Relevance CSP | Overview | How to Propose a Project | Review Process | DOE Relevance Proposal Schedule | FAQ The Department of Energy Joint Genome Institute (DOE JGI) is managed by the Department of Energy's Office of Biological and Environmental Research (OBER) to produce high-throughput DNA sequencing and analysis in support of its missions in alternative energy, global carbon cycling, and biogeochemistry. These areas mirror DOE and national priorities to develop abundant sources of clean energy, to control greenhouse gas accumulation in

407

DOE Public Reading Room  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

environmental and waste management, and site-specific concerns. The INL Research Library provides access to information, staffing, and research assistance for the DOE Reading...

408

DOE Explosives Safety Manual  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Manual describes DOE's explosives safety requirements applicable to operations involving the development, testing, handling, and processing of explosives or assemblies containing explosives.

1996-03-29T23:59:59.000Z

409

Energy Innovations DOE Meeting  

Broader source: Energy.gov [DOE]

Leo Breton, representing Energy Innovations of Washington, DC, a small company engaged in improving the energy efficiency of appliances, automobiles, and HVAC systems, requested a meeting with DOE...

410

DOE MENTOR-PROTG  

Energy Savers [EERE]

provided. * Equipping small businesses and minority institutions of higher with the knowledge, skills and capabilities needed to successfully compete for DOE prime contracts. *...

411

DOE General Competencies  

Broader source: Energy.gov [DOE]

The DOE General Competencies are the personal and professional attributes that are critical to successful performance. A competency model is a collection of competencies that together define...

412

the DOE ISMS Review  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

* Corrective action management * Environmental management * Commercial grade dedication * Conduct of operations "This ISMS review by DOE goes beyond ensuring that we have a...

413

DOE Corporate Overview - 2012  

Broader source: Energy.gov (indexed) [DOE]

U.S. Department of Energy, 2012 Section One, page 1 U.S. Department of Energy, 2012 Section One, page 1 SECTION ONE INTRODUCTION TO THE DEPARTMENT OF ENERGY EXECUTIVE SUMMARY Welcome to the Department of Energy. This book provides an overview of the Department of Energy (DOE). The opening sections describe the mission areas, organizational structure and upcoming critical issues of the Department, followed by brief descriptions of DOE's goals and programs. Later sections provide overviews of the Department's budget, staffing, contract management, project management, Congressional jurisdiction, Government Accountability Office (GAO) and DOE's Inspector General (IG) oversight and DOE high-visibility

414

Word Order Variables in Patzun Kaqchikel  

E-Print Network [OSTI]

with the previous analysis of word orders in (Patzicia) Kaqchikel by Broadwell (2000).2 In Patzun Kaqchikel, in intransitive clauses, either SV word order or VS word order is possible in statements and questions. (1) a. ri n...-tzih n-anin3 def poss.1sg-dog inc.3sA-run My dog runs. SV+statement Does my dog run? SV+question b. n-anin ri n-tzih inc.3s...

Kim, Sok-Ju

2011-10-03T23:59:59.000Z

415

CRAD, Feedback and Continuous Improvement - DOE Headquarters - December 4,  

Broader source: Energy.gov (indexed) [DOE]

CRAD, Feedback and Continuous Improvement - DOE Headquarters - CRAD, Feedback and Continuous Improvement - DOE Headquarters - December 4, 2007 CRAD, Feedback and Continuous Improvement - DOE Headquarters - December 4, 2007 December 4, 2007 Feedback and Continuous Improvement Inspection Criteria and Approach - DOE Headquarters (HSS CRAD 64-22) The Department of Energy (DOE) Headquarters line management has established and implemented effective oversight processes that evaluate the adequacy and effectiveness of field element assurance systems and DOE oversight processes. DOE Headquarters assurance system programs and processes are in accordance with the policy and key elements outlined in DOE Policy 226.1, Department of Energy Oversight Policy; DOE Order 226. 1A, Implementation of Department of Energy Oversight Policy, Attachment 2, quality assurance

416

DOE-TSL-2-2002 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

2-2002 2-2002 DOE-TSL-2-2002 September 24, 2002 Directory of Points of Contact for the DOE Technical Standards Program Replaced by DOE-TSL-2-2006 | Supersedes DOE-TSL-2-98 (January 1998) This TSL supplements DOE manuals, directives, orders, and standards. It provides basic and fundamental information for DOE Component personnel involved in identifying standardization documents. It also provides listings of points of contact within DOE and identifies links to points of contact within the Department of Defense (DoD) for coordination of standardization activities. DOE-TSL-2-2002, Directory of Points of Contact for the DOE Technical Standards Program More Documents & Publications Technical Standards Newsletter - August 2006 Technical Standards Newsletter- April 2008

417

DOE-STD-1030-95; DOE Standard Guide to Good Practices For Lockouts and Tagouts  

Broader source: Energy.gov (indexed) [DOE]

1030-96 1030-96 May 1996 Supercedes DOE-STD-1030-92 DOE STANDARD GUIDE TO GOOD PRACTICES FOR LOCKOUTS AND TAGOUTS U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE96009465 DOE-STD-1030-96 iii FOREWORD The purpose of this Guide to Good Practices is to provide Department of Energy (DOE) contractors with information that can be used to validate and/or modify existing programs

418

DOE-STD-1075-94; DOE Standard Guide for Operational Configuration Management Program  

Broader source: Energy.gov (indexed) [DOE]

5-94 5-94 July 1994 DOE STANDARD STANDARD FOR DEVELOPING AND ISSUING DOE SAFETY GUIDES AND IMPLEMENTATION GUIDES U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE94018438 DOE-STD-1075-94 iii FOREWORD 1. This Department of Energy (DOE) standard was prepared by the Office of Environment, Safety and Health with the assistance of James E. Konklin of

419

DOE-STD-1077-94; DOE Standard Training Accreditation Program Standard: Requirements and Guidelines  

Broader source: Energy.gov (indexed) [DOE]

7-94 7-94 August 1994 Supercedes DOE-STD-0101T, TAP-1, and DOE-STD-0103T, TAP-3 DOE STANDARD TRAINING ACCREDITATION PROGRAM STANDARD: REQUIREMENTS AND GUIDELINES U.S. Department of Energy Washington, D.C. 20585 FSC 6910 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE94018723 DOE-STD-1077-94 FOREWORD The Training Accreditation Program was established by the Department of Energy

420

DOE-STD-1070-94; DOE Standard Guidelines for Evalation of Nuclear Facility Training Programs  

Broader source: Energy.gov (indexed) [DOE]

DOE-STD-1070-94 June 1994 DOE STANDARD GUIDELINES FOR EVALUATION OF NUCLEAR FACILITY TRAINING PROGRAMS U.S. Department of Energy FSC-6910 Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615)576-8401. Available to the public from the U. S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA. 22161; (703)487-4650. Order No. DE94015536 DOE-STD-1070-94 iii FOREWORD The Department of Energy (DOE) Guidelines for Evaluation of Nuclear Facility Training

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

2012 DOE Strategic Sustainability Performance Plan | Department...  

Broader source: Energy.gov (indexed) [DOE]

DOE Strategic Sustainability Performance Plan 2012 DOE Strategic Sustainability Performance Plan The 2012 DOE Strategic Sustainability Performance Plan embodies DOE's...

422

DOE standard: Radiological control  

SciTech Connect (OSTI)

The Department of Energy (DOE) has developed this Standard to assist line managers in meeting their responsibilities for implementing occupational radiological control programs. DOE has established regulatory requirements for occupational radiation protection in Title 10 of the Code of Federal Regulations, Part 835 (10 CFR 835), ``Occupational Radiation Protection``. Failure to comply with these requirements may lead to appropriate enforcement actions as authorized under the Price Anderson Act Amendments (PAAA). While this Standard does not establish requirements, it does restate, paraphrase, or cite many (but not all) of the requirements of 10 CFR 835 and related documents (e.g., occupational safety and health, hazardous materials transportation, and environmental protection standards). Because of the wide range of activities undertaken by DOE and the varying requirements affecting these activities, DOE does not believe that it would be practical or useful to identify and reproduce the entire range of health and safety requirements in this Standard and therefore has not done so. In all cases, DOE cautions the user to review any underlying regulatory and contractual requirements and the primary guidance documents in their original context to ensure that the site program is adequate to ensure continuing compliance with the applicable requirements. To assist its operating entities in achieving and maintaining compliance with the requirements of 10 CFR 835, DOE has established its primary regulatory guidance in the DOE G 441.1 series of Guides. This Standard supplements the DOE G 441.1 series of Guides and serves as a secondary source of guidance for achieving compliance with 10 CFR 835.

Not Available

1999-07-01T23:59:59.000Z

423

DOE Radiation Records Contacts List  

Broader source: Energy.gov [DOE]

DOE radiation records contact list for individuals to obtain records of occupational exposure directly from a DOE site.

424

DOE Explosives Safety Manual  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Manual describes the Departments explosive safety requirements applicable to operations involving the development, testing, handling, and processing of explosives or assemblies containing explosives. Cancels DOE M 440.1-1. Canceled by DOE O 440.1B Chg 1.

2006-01-09T23:59:59.000Z

425

DOE/ID-Number  

Broader source: Energy.gov (indexed) [DOE]

54 54 Draft Environmental Assessment for the Resumption of Transient Testing of Nuclear Fuels and Materials Draft November 2013 DOE/EA-1954 Draft Environmental Assessment for the Resumption of Transient Testing of Nuclear Fuels and Materials Draft November 2013 U.S. Department of Energy DOE Idaho Operations Office ii CONTENTS LIST OF FIGURES ..................................................................................................................... iii LIST OF TABLES....................................................................................................................... iv ACRONYMS .............................................................................................................................. v

426

Notice of Intent to Develop DOE O 470.5, Integrating Existing Technical Security Program Requirements  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This memorandum provides justification for the development of one integrated and consolidated set of requirements for the Department of Energy (DOE) Technical Security Program (TSP). This Order will combine the existing necessary requirements from DOE Manual (M) 205.1-3, Telecommunications Security Manual, dated 4-17-2006 and DOE M 470.4-4A chg.1, Information Security Manual, dated 10-12-2010; Section D -Technical Surveillance Countermeasures, into a single DOE Order defining the DOE TSP.

2013-08-21T23:59:59.000Z

427

Order Module--NNSA Orders Self-Study Program Safety Basis Documentation |  

Broader source: Energy.gov (indexed) [DOE]

NNSA Orders Self-Study Program Safety Basis NNSA Orders Self-Study Program Safety Basis Documentation Order Module--NNSA Orders Self-Study Program Safety Basis Documentation The familiar level of this module is divided into five sections. In the first section, we will discuss the regulation. In the second, third, and fourth sections, we will discuss the U. Department of Energy (DOE) guides for documented safety analyses (DSAs), technical safety requirements (TSRs), and unreviewed safety questions (USQs). Section 5 discusses the DOE standard related to DSAs and TSRs. We have provided several examples and practices throughout the module to help familiarize you with the material. The practices will also help prepare you for the criterion test. DOE Order Self Study Modules - 10 CFR 830 Safety Basis Documentation

428

DOE CORPORATE REPORTING  

Broader source: Energy.gov (indexed) [DOE]

7/23/2010 7/23/2010 1 DEPARTMENT OF ENERGY (DOE) CORPORATE REPORTING To ensure projects are effectively managed and delivering on the goals of the American Recovery and Reinvestment Act (Recovery Act), DOE will collect data on project management and execution, risk management, job creation, and key project milestones, in addition to what is required by Section 1512 of the Recovery Act. In most cases, monthly data will be used internally for managerial purposes only, but where DOE does intend to publicize monthly data, it will clearly indicate it to be "preliminary/informal and subject to change." Recipients are required to provide DOE information on, but not limited to, the following issues:

429

DOE Patents Database - Widget  

Office of Scientific and Technical Information (OSTI)

Get the DOepatents Widget... Get the DOepatents Widget... Download the DOepatents widget to find DOE patent data, read news about DOE inventions, and browse the most-viewed patents. You may download and install this widget using the html inclusion code. Get the DOepatents widget and many other great free widgets at Widgetbox! Not seeing a widget? (More info) Widget Features Search: Find patent information resulting from DOE-sponsored research and development (R&D) dating from the 1940s to today. Most Viewed: Browse the most frequently viewed patent records. News: Read about highlighted DOE inventions and inventors. Featured: View recently issued patents and patents owned exclusively by DOE. Contact: Send comments or questions about this collection. XML: Link directly to the DOepatents XML data service, with help and

430

DOE Grids Service Transition  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DOE Grids Service Transition DOE Grids Service Transition Services Overview ECS Audio/Video Conferencing Fasterdata IPv6 Network Network Performance Tools (perfSONAR) ESnet OID Registry PGP Key Service Virtual Circuits (OSCARS) DOE Grids Service Transition Contact Us Technical Assistance: 1 800-33-ESnet (Inside the US) 1 800-333-7638 (Inside the US) 1 510-486-7600 (Globally) 1 510-486-7607 (Globally) Report Network Problems: trouble@es.net Provide Web Site Feedback: info@es.net DOE Grids Service Transition Background ESnet has decided to transition support and management for the certificate services provided by the DOE Grids public key infrastructure (PKI) to the Open Sciences Grid (OSG). OSG and ESnet provide service to many of the same user communities, and have long been collaborators in the areas of identity

431

DOE Patents Database - About  

Office of Scientific and Technical Information (OSTI)

About DOepatents About DOepatents DOepatents, developed by the U.S. Department of Energy (DOE) Office of Scientific and Technical Information (OSTI), is a searchable database of patent information resulting from DOE-sponsored research and development (R&D). Included here are patents that DOE sponsored through a variety of funding mechanisms, including grants, contracts, or cooperative agreements. Comprehensive coverage of DOE patent information is one way to demonstrate the Department's contribution to scientific progress in the physical sciences and other disciplines. Publicly available patent information from DOE R&D, historic and current, is presented here, excluding patent applications. DOepatents consists of bibliographic records, with full text where available, either via a PDF file or an HTML link to the record at the

432

DOE Energy Innovation Hubs  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Research » DOE Energy Research » DOE Energy Innovation Hubs Basic Energy Sciences (BES) BES Home About Research Materials Sciences & Engineering (MSE) Chemical Sciences, Geosciences, and Biosciences (CSGB) Accelerator and Detector Research Research Conduct Policies DOE Energy Innovation Hubs Energy Frontier Research Centers National Nanotechnology Initiative (NNI) Facilities Science Highlights Benefits of BES Funding Opportunities Basic Energy Sciences Advisory Committee (BESAC) News & Resources Contact Information Basic Energy Sciences U.S. Department of Energy SC-22/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-3081 F: (301) 903-6594 E: sc.bes@science.doe.gov More Information » Research DOE Energy Innovation Hubs Print Text Size: A A A RSS Feeds

433

DOE-2 basics  

SciTech Connect (OSTI)

DOE-2 provides the building design and research communities with an up-to-date, unbiased, well-documented public-domain computer program for building energy analysis. DOE-2 predicts the hourly energy use and energy cost of a building given hourly weather information and a description of the building and its HVAC equipment and utility rate structure. DOE-2 is a portable FORTRAN program that can be used on a large variety of computers, including PC's. Using DOE-2, designers can determine the choice of building parameters that improve energy efficiency while maintaining thermal comfort. The purpose of DOE-2 is to aid in the analysis of energy usage in buildings; it is not intended to be the sole source of information relied upon for the design of buildings. The judgment and experience of the architect/engineer still remain the most important elements of building design.

Not Available

1991-08-01T23:59:59.000Z

434

DOE-2 basics  

SciTech Connect (OSTI)

DOE-2 provides the building design and research communities with an up-to-date, unbiased, well-documented public-domain computer program for building energy analysis. DOE-2 predicts the hourly energy use and energy cost of a building given hourly weather information and a description of the building and its HVAC equipment and utility rate structure. DOE-2 is a portable FORTRAN program that can be used on a large variety of computers, including PC`s. Using DOE-2, designers can determine the choice of building parameters that improve energy efficiency while maintaining thermal comfort. The purpose of DOE-2 is to aid in the analysis of energy usage in buildings; it is not intended to be the sole source of information relied upon for the design of buildings. The judgment and experience of the architect/engineer still remain the most important elements of building design.

Not Available

1991-08-01T23:59:59.000Z

435

DOE-STD-1041-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

1-93 1-93 DOE-STD-1041-93 January 11, 1999 Guide to Good Practices for Shift Routines and Operating Practices Change Notice No. 1 (December 1998) | Reaffirmed 2001 This Guide to Good Practices is written to enhance understanding of, and provide direction for, "Shift Routines and Operating Practices," Chapter II of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. "Shift Routines and Operating Practices" is an element of an effective Conduct of Operations program. DOE-STD-1041-93, Guide to Good Practices for Shift Routines and Operating Practices More Documents & Publications Order Module--DOE Order 422.1, CONDUCT OF OPERATIONS OPS 9.2 Shift Routines and Operating Practices 8/24/98 DOE-STD-1038-93

436

DOE-STD-1041-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

1-93 1-93 DOE-STD-1041-93 January 11, 1999 Guide to Good Practices for Shift Routines and Operating Practices Change Notice No. 1 (December 1998) | Reaffirmed 2001 This Guide to Good Practices is written to enhance understanding of, and provide direction for, "Shift Routines and Operating Practices," Chapter II of Department of Energy (DOE) Order 5480.19, Conduct of Operations Requirements for DOE Facilities. "Shift Routines and Operating Practices" is an element of an effective Conduct of Operations program. DOE-STD-1041-93, Guide to Good Practices for Shift Routines and Operating Practices More Documents & Publications OPS 9.2 Shift Routines and Operating Practices 8/24/98 Order Module--DOE Order 422.1, CONDUCT OF OPERATIONS DOE-STD-1038-93

437

DOE Technical Standards Archived Collection | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

sort ascending Title Date sort ascending Title Date DOE-TSL-4-99 Directory of DOE and Contractor Personnel Involved in Non-Government Standards Activities; Directory of DOE and Contractor Personnel Involved in Non-Government Standards Activities Superseding DOE-TSL-4-98 May 1998 The body of this document contains a listing of DOE employees and DOE contractors who have submitted form DOE F 1300.2, Record of Non-Government Standards Activity, which is attached to the end of this document. 05/21/1999 DOE-TSL-2-2002 Directory of Points of Contact for the DOE Technical Standards Program Replaced by DOE-TSL-2-2006 | Supersedes DOE-TSL-2-98 (January 1998) This TSL supplements DOE manuals, directives, orders, and standards. It provides basic and fundamental information for DOE Component personnel involved in identifying standardization documents. It also provides listings of points of contact within DOE and identifies links to points of contact within the Department of Defense (DoD) for coordination of standardization activities. 09/24/2002

438

DOE ORP Contracting Officer Representatives - Hanford Site  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DOE ORP Contracting Officer Representatives DOE - ORP ContractsProcurements ORP Contracts & Procurements Home DOE-ORP Contract Management Plans DOE-ORP Prime Contracts DOE-ORP...

439

DOE - ORP Contracts/Procurements - Hanford Site  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Procurements Home DOE-ORP Contract Management Plans DOE-ORP Prime Contracts DOE-ORP Contracting Officers DOE ORP Contracting Officer Representatives DOE ORP Purchase Card Buyers...

440

DOE G 200  

Broader source: Energy.gov (indexed) [DOE]

G 200.1-1A G 200.1-1A Department of Energy (DOE) Systems Engineering Methodology Version 3 The DOE Systems Development Lifecycle (SDLC) for Information Technology Investments September 2002 U. S. DEPARTMENT OF ENERGY Office of the Chief Information Officer Date: September 2002 Page Rev Date: i TITLE PAGE Document Name: Department of Energy Systems Engineering Methodology (SEM) The DOE Systems Development Lifecycle (SDLC) for Information Technology Investments Publication Date: Original March 1996; Revised November 1997 Version 2 March 1999 Version 3 September 2002 Approval: ___________________________________ Karen Evans, Chief Information Officer ___________________________________ Brenda Coblentz, Program Manager, Software Quality & Systems Engineering

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

DOE Site List  

Office of Environmental Management (EM)

Links Links Central Internet Database CID Photo Banner DOE Site List Site Geo Site Code State Operations Office1 DOE Programs Generating Streams at Site DOE Programs Managing Facilities Associated Data2 Acid/Pueblo Canyons ACPC NM Oak Ridge Waste/Media, Facilities Airport Substation CA Western Area Power Administration Facilities Akron Hill Communication Site CO Western Area Power Administration Facilities Akron Substation CO Western Area Power Administration Facilities AL Complex NM Albuquerque DP Facilities Alba Craft ALCL OH Oak Ridge Facilities Albany Research Center AMRC OR Oak Ridge Facilities Alcova Switchyard WY Western Area Power Administration Facilities Aliquippa Forge ALFO PA Oak Ridge Facilities

442

DOE Distribution Workshop Attendees  

Broader source: Energy.gov (indexed) [DOE]

1 Laurie Actman Deputy Director EEB Hub Chris Ainscough Senior Engineer National renewable Energy Joe Allen Director of Government Relations Caterpillar / Solar Turbines Robert Anders Mr. U.S. Department of Energy - EERE David Anderson Technology Development Manager Department of Energy Sam Baldwin Chief Science Officer EERE/DOE Thomas Baldwin Conv Renewables Group Lead Idaho National Venkat Banunarayanan Grid Integration & Solar Forecasting Department of Energy - SunShot Vincent Battaglia Deputy Department Head ESDR LBNL Gil Bindewald General Engineer US DOE/Office of Electricity Delivery & Energy Reliability Anjan Bose Grid Tech Team Lead DOE/Office of Electricity Delivery and Energy Reliability Ralph Braccio

443

DOE Average Results  

Broader source: Energy.gov (indexed) [DOE]

DOE DOE Average Results FY 12 DOE Target FY 12 Customer Perspective: Customer Satisfaction: -Timeliness 92 88 -Quality 94 92 Effective Service Partnership: -Extent of Customer Satisfaction with the responsiveness, etc. 90 92 Internal Business Perspective: Acquisition Excellence: -Extent to which internal quality control systems are effective 90 88 Most Effective Use of Contracting Approaches to Maximize Efficiency and Cost Effectiveness: Use of Competition: -% of total $'s obligated on competitive acquisitions >$3000 (Agency Level Only) 94 85 -% of acquisition actions competed for actions > $3000 (Agency Level Only) 65 68 Performance Based Acquisition: - % PBA actions relative to total eligible new acquisition actions (applicable to new actions > $25K) 82

444

Radiological Protection for DOE Activities  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

Establishes radiological protection program requirements that, combined with 10 CFR 835 and its associated implementation guidance, form the basis for a comprehensive program for protection of individuals from the hazards of ionizing radiation in controlled areas. Extended by DOE N 441.3. Cancels DOE 5480.11, DOE 5480.15, DOE N 5400.13, DOE N 5480.11; please note: the DOE radiological control manual (DOE/EH-0256T)

1995-09-29T23:59:59.000Z

445

DOE Standard 1020 - Natural Phenomena Hazard analysis and Design Criteria  

Broader source: Energy.gov (indexed) [DOE]

DOE Standard 1020 - Natural Phenomena Hazard analysis and Design DOE Standard 1020 - Natural Phenomena Hazard analysis and Design Criteria for DOE Facilities DOE Standard 1020 - Natural Phenomena Hazard analysis and Design Criteria for DOE Facilities Department of Energy (DOE) Standard (STD)-1020-2012, Natural Phenomena Hazards Analysis and Design Criteria for DOE Facilities, provides criteria and guidance for the analysis and design of facility structures, systems, and components (SSCs) that are necessary to implement the requirements of DOE Order (O) 420.1C, Facility Safety, and to ensure that the SSCs will be able to effectively perform their intended safety functions under the effects of natural phenomena hazards (NPHs). This Standard also provides criteria and guidance for the use of industry building codes and voluntary

446

Exceptions to DOE Rules and Regulations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Exceptions to DOE Rules and Regulations Exceptions to DOE Rules and Regulations Exceptions to DOE Rules and Regulations The Department of Energy (DOE) issues test procedures and regulations covering a number of products, but does provide for exceptions to these rules under certain circumstances. Any person, as defined by 10 CFR 1003.2, can apply to the DOE for an exception from a rule, regulation, or DOE action having the effect of a rule, as provided for in section 504 of 42 U.S.C. 7194 and codified in 10 CFR 1003 subpart B. The DOE Office of Hearings and Appeals (OHA) is responsible for issuing an order either granting or denying the application, in whole or in part, based upon a showing of serious hardship, gross inequity or unfair distribution of burdens, after considering the application and other

447

DOE-STD-3007-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

93 93 DOE-STD-3007-93 September 17, 1998 Guidelines for Preparing Criticality Safety Evaluations at Department of Energy Non-Reactor Nuclear Facilities Replaced by DOE-STD-3007-2007 | CHANGE NOTICE NO. 1 (September 1998) Contained in this document are guidelines that should be followed when preparing Criticality Safety Evaluations that will be used to demonstrate the safety of operations performed at Department of Energy (DOE) Non-Reactor Nuclear Facilities. DOE-STD-3007-93, Guidelines for Preparing Criticality Safety Evaluations at Department of Energy Non-Reactor Nuclear Facilities; Replaced by DOE-STD-3007-2007 More Documents & Publications DOE-STD-1134-99 DOE-STD-1135-99 Technical Standards, DOE Orders and Applicable CFRs/DEAR Crosswalk - February 2, 2002

448

DOE O 481.1A  

Broader source: Energy.gov (indexed) [DOE]

All Departmental Elements Office of Management and Administration U.S. Department of Energy ORDER Washington, D.C. Approved: 01-03-01 Sunset Review: 01-03-03 Expires: 01-03-05 SUBJECT: WORK FOR OTHERS (NON-DEPARTMENT OF ENERGY FUNDED WORK) 1. OBJECTIVES. Work for Others (WFO) is the performance of work for non-Department of Energy (DOE) entities by DOE/National Nuclear Security Administration (NNSA) and/or their respective contractor personnel or the use of DOE/NNSA facilities that is not directly funded by DOE appropriations. WFO has the following objectives. a. To provide assistance to other Federal agencies and non-Federal entities in accomplishing goals that may otherwise be unattainable and to avoid the possible duplication of effort at Federal facilities.

449

DOE Removes Brookhaven Contractor  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DOE Removes DOE Removes Brookhaven Contractor Peña sends a message to DOE facilities nationwide INSIDE 2 Accelerator Rx 4 FermiKids 6 Spring at Fermilab Photos courtesy of Brookhaven National Laboratory by Judy Jackson, Office of Public Affairs Secretary of Energy Federico Peña announced on Thursday, May 1, that the Department of Energy would immediately terminate the current management contract with Associated Universities, Inc. at Brookhaven National Laboratory in Upton, New York. Peña said that he made the decision after receiving the results of a laboratory safety management review conducted by the independent oversight arm of DOE's Office of Environment, Safety and Health. In addition, the Secretary said he found unacceptable "the continued on page 8 Volume 20 Friday, May 16, 1997

450

DOE/EA-1807  

Broader source: Energy.gov (indexed) [DOE]

7 7 FINAL ENVIRONMENTAL ASSESSMENT FOR HEARTLAND COMMUNITY COLLEGE WIND ENERGY PROJECT NORMAL, MCLEAN COUNTY, ILLINOIS U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Golden Field Office DECEMBER 2010 DOE/EA 1807 FINAL ENVIRONMENTAL ASSESSMENT FOR HEARTLAND COMMUNITY COLLEGE WIND ENERGY PROJECT NORMAL, MCLEAN COUNTY, ILLINOIS U.S. Department of Energy Office of Energy Efficiency and Renewable Energy Golden Field Office DECEMBER 2010 DOE/EA 1807 iii December 2010 C OV E R S HE E T R E SPONSI B L E A G E NC Y : U.S. Department of Energy (DOE) T I T L E : Final Environmental Assessment for Heartland Community College Wind Energy Project, Normal, McLean County, Illinois (DOE/EA 1807). C ONT A C T : For additional copies or more information on this Environmental Assessment

451

DOE 2014 Biomass Conference  

Broader source: Energy.gov [DOE]

Breakout Session 1CFostering Technology Adoption I: Building the Market for Renewables with High Octane Fuels DOE 2014 Biomass Conference Jim Williams, Senior Manager, American Petroleum Institute

452

DOE/ID-Number  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

www.inl.gov Prepared for the U.S. Department of Energy Office of Nuclear Energy Under DOE Idaho Operations Office Contract DE-AC07-05ID14517 ii EXECUTIVE SUMMARY The U.S....

453

DOE Reg. Burden RFI  

Broader source: Energy.gov (indexed) [DOE]

January 4, 2012 January 4, 2012 Page 1 January 4, 2012 Daniel Cohen, Esq. Office of General Counsel U.S. Department of Energy 1000 Independence Avenue, SW Washington, DC 20585 Re: Regulatory Burden RFI Dear Mr. Cohen: These comments are submitted by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) in response to the U.S. Department of Energy's (DOE) notice in the December 5, 2011 Federal Register requesting information to assist DOE in reviewing existing regulations and in making its regulatory program more effective and less burdensome. AHRI had submitted comments on March 21, 2011 in response to the previous Request for Information (RFI) issued by DOE in February of 2011. We appreciate DOE's commitment to maintaining a plan for regular, periodic review of its existing regulations and reporting

454

DOE Robotics Project  

SciTech Connect (OSTI)

This document provide the bimonthly progress reports on the Department of Energy (DOE) Robotics Project by the University of Michigan. Reports are provided for the time periods of December 90/January 91 through June 91/July 91. (FI)

Not Available

1991-01-01T23:59:59.000Z

455

DOE Corporate FEOSH  

Broader source: Energy.gov [DOE]

The Department of Energy (DOE) Federal Employee Occupational Safety and Health (FEOSH) Program web site is the connection to current safety and health news and issues: Departmental special emphasis initiatives, upcoming activities, resources, contacts, and much, much more.

456

DOE-STD-1196-2011  

Broader source: Energy.gov [DOE]

Concentration Technical Standard This standard supports the implementation of Department of Energy (DOE) Order 458.1, Radiation Protection of the Public and the Environment. It also establishes the numerical values of DCSs in a manner reflecting the current state of knowledge and practice in radiation protection

457

Order Module--RADIATION PROTECTION PROGRAMS GUIDE | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

RADIATION PROTECTION PROGRAMS GUIDE RADIATION PROTECTION PROGRAMS GUIDE Order Module--RADIATION PROTECTION PROGRAMS GUIDE The familiar level of this module is designed to provide the basic information related to DOE G 441.1-1C, Radiation Protection Programs Guide, as required in DOE-STD-1174-2003, Radiation Protection Functional Area Qualification Standard, December 2003. Completion of this module also meets certain requirements associated with the DOE Facility Representative Program and the DOE Intern Program. The information contained in this module addresses specific requirements and as such does not include the entire text of the source document. Before continuing, you should obtain a copy of the Order. Copies of the DOE Directives are available at http://www.directives.doe.gov/ or through the course manager. In March

458

Microsoft Word - S05979_DOE-LM_Executable Plan2009-Final_Rev 2changes accepted_.doc  

Broader source: Energy.gov (indexed) [DOE]

Order 430.2B Order 430.2B Executable Plan for LM (DOE FEMP Final) December 2009 LMS/S05979 This page intentionally left blank Signature for Site DOE Order 430.2B Executable Plan for LM (DOE FEMP Final) Office Concurrence This page intentionally left blank U.S. Department of Energy DOE Order 430.2B Executable Plan for LM (DOE FEMP Draft) December 2009 Doc. No. S05979 Page i Contents 1.0 Executive Summary ............................................................................................................ 1 2.0 DOE Order 430.2B Goal Summary Progress ..................................................................... 2 3.0 Energy Intensity ..................................................................................................................

459

DOE-STD-1083-95; DOE Standard Requesting and Granting Exemptions to Nuclear Safety Rules  

Broader source: Energy.gov (indexed) [DOE]

3-95 3-95 February 1995 DOE STANDARD REQUESTING AND GRANTING EXEMPTIONS TO NUCLEAR SAFETY RULES U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE95007451 DOE-STD-1083-95 iii FOREWORD 1. This Department of Energy (DOE) standard has been prepared by the Office of Environment, Safety and Health with the assistance of Hank George of Synergy Consultants and

460

DOE-EM-STD-5502-94; DOE Limited Standard Hazard Baseline Documentation  

Broader source: Energy.gov (indexed) [DOE]

NOT MEASUREMENT SENSITIVE DOE-EM-STD-5502-94 August 1994 DOE LIMITED STANDARD HAZARD BASELINE DOCUMENTATION U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE94016623 DOE-EM-STD-5502-94

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

DOE-STD-3014-96; DOE Standard Accident Analysis For Aircraft Crash Into Hazardous Facilities  

Broader source: Energy.gov (indexed) [DOE]

DOE STANDARD DOE STANDARD October 1 996 Reaffirmation May 2006 ACCIDENT CRASH INTO ANALYSIS HAZARDOUS FACILITIES U.S. Department of Energy Washington, DC 20585 AREA SAFT DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. FOR AIRCRAFT This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE97000162 DOE-STD-3014-96 iii TABLE OF CONTENTS PARAGRAPH PAGE FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

462

DOE-HDBK-1081-94; DOE Handbook Primer on Spontanious Heating and Pyrophoricity  

Broader source: Energy.gov (indexed) [DOE]

DOE-HDBK-1081-94 December 1994 DOE HANDBOOK PRIMER ON SPONTANEOUS HEATING AND PYROPHORICITY U.S. Department of Energy FSC-6910 Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information. P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161. (703) 487-4650 Order No. DE95003576 DOE-HDBK-1081-94 SPONTANEOUS HEATING AND PYROPHORICITY Rev. 0 Pyrophoricity FOREWORD The Primer on Spontaneous Heating and Pyrophoricity is approved for use by all

463

DOE-HDBK-1074-95; DOE Handbook Alternative Systematic Approaches to Training  

Broader source: Energy.gov (indexed) [DOE]

DOE-HDBK-1074-95 January 1995 DOE HANDBOOK ALTERNATIVE SYSTEMATIC APPROACHES TO TRAINING U.S. Department of Energy FSC-6910 Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE95006851 DOE-HDBK-1074-95 TABLE OF CONTENTS PARAGRAPH PAGE FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i SCOPE . . . . .

464

DOE-EM-STD-5505-96; DOE Limited Standard Operations Assessments  

Broader source: Energy.gov (indexed) [DOE]

EM-STD-5505-96 EM-STD-5505-96 May 1996 DOE LIMITED STANDARD OPERATIONS ASSESSMENTS U.S. Department of Energy AREA OPER Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 487-4650. Order No. DE96009462 DOE-EM-STD-5505-96 iii FOREWORD 1. This Department of Energy limited standard is approved for use by all DOE-EM field components. 2. Beneficial comments (recommendations, additions, deletions) and any pertinent data that

465

Implementation Guide for Use with DOE O 450.1, Environmental Protection Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Guide provides background information, an overview of the integration process and guidance relating to the preliminary steps that DOE sites should undertake in order to meet the requirements of DOE O 450.1. Canceled by DOE N 251.96. Cancels DOE G 450.1-1.

2005-10-24T23:59:59.000Z

466

Accelerator Facility Safety Implementation Guide for DOE O 420.2B, Safety of Accelerator Facilities  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This document is an aid to understanding and meeting the requirements of DOE O 420.2B, Safety of Accelerator Facilities, dated 7/23/04. It does not impose requirements beyond those stated in that Order or any other DOE Order. No cancellation.

2005-07-01T23:59:59.000Z

467

DOE Policy on Decommissioning DOE Facilities Under CERCLA | Department of  

Broader source: Energy.gov (indexed) [DOE]

DOE Policy on Decommissioning DOE Facilities Under DOE Policy on Decommissioning DOE Facilities Under CERCLA DOE Policy on Decommissioning DOE Facilities Under CERCLA In May 1995, the Department of Energy (DOE) issued a policy in collaboration with the Environmental Protection Agency (EPA) for decommissioning surplus DOE facilities consistent with the requirements of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). This policy ensures protection of the environment, worker health and public health, provides opportunities for stakeholder involvement, and achieves risk reduction without unnecessary delay. Consistent with the jointly issued "Guidance on Accelerating CERCLA Environmental Restoration at Federal Facilities" (August 22, 1994), this decommissioning policy encourages streamlined decision-making. This

468

Political Activity at DOE Facilities and by DOE Contractors ...  

Broader source: Energy.gov (indexed) [DOE]

and by DOE Contractors The Policy Flash from October 5, 2011, serves to remind Contracting Officers of restrictions on political activity by DOE contractors at the Department...

469

Quality Assurance Management System Guide for Use with 10 CFR 830.120 and DOE O 414.1  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

DOE Elements and DOE contractors should consult this Guide in order to develop and implement effective management systems that are consistent with the Department's quality expectations and that support the Safety Management System Policy, DOE P 450.4. Canceled by DOE G 414.1-2A. Does not cancel other directives.

1999-06-17T23:59:59.000Z

470

DOE Directives | Department of Energy  

Office of Environmental Management (EM)

DOE G 414.1-2B Admin Change 1, Quality Assurance Program Guide DOE O 221.1A, Reporting Fraud, Waste and Abuse to the Office of the Inspector General DOE O 232.2, Occurrence...

471

DOE Ex Parte Communication Memorandum  

Broader source: Energy.gov [DOE]

On Thursday March 20th, energy efficiency experts held a teleconference call withtrepresentatives of the US Department of Energy (DOE) to discuss DOEs proposed determination for computer systems.

472

Worker Protection Management for DOE Federal and Contractor Employees |  

Broader source: Energy.gov (indexed) [DOE]

Services » Program Management » Safety » Worker Protection Services » Program Management » Safety » Worker Protection Management for DOE Federal and Contractor Employees Worker Protection Management for DOE Federal and Contractor Employees This Order establishes the framework for an effective worker protection program that will reduce or prevent injuries, illnesses and accidental losses by providing DOE Federal and contractor workers with a safe and healthful workplace. Worker Protection Management for DOE Federal and Contractor Employees More Documents & Publications CRAD, Machine Shop Safe Operations Assessment Plan Order Module--DOE O 440.1B, WORKER PROTECTION PROGRAM FOR DOE (INCLUDING NNSA) FEDERAL EMPLOYEES Audit Report: IG-0404 Waste Management Nuclear Materials & Waste Tank Waste and Waste Processing

473

links | netl.doe.gov  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Engines U. S. DEPARTMENT OF ENERGY INFORMATION SOURCES Department of Energy (DOE) Clean Coal Technology Compendium DOE Labs Energy Efficiency and Renewable Energy Network (EREN)...

474

GE_Order_and_Compromise_Agreement.pdf  

Broader source: Energy.gov (indexed) [DOE]

GE Appliances, a Division of GE Appliances, a Division of General Electric Company, Respondent ) ) ) ) ) ) ORDER By the General Counsel, U.S. Department of Energy: Case Number: 2012-SE-1403 1. In this Order, I adopt the attached Compromise Agreement entered into between the U.S. Department of Energy ("DOE") and GE Appliances, a Division of General Electric Company ("Respondent"). The Compromise Agreement resolves the case initiated after DOE was informed, based on test results made available as a result of verification testing by the Association of Home Appliance Manufacturers ("AHAM"), that aGE refrigerator basic model may not meet the energy conservation standard set forth in 10 C.F.R. § 430.32(a). 2. DOE and Respondent have negotiated the terms of the Compromise Agreement that

475

DOE Exascale Initiative  

Broader source: Energy.gov (indexed) [DOE]

DOE Exascale Initiative Dimitri Kusnezov, Senior Advisor to the Secretary, US DOE Steve Binkley, Senior Advisor, Office of Science, US DOE Bill Harrod, Office of Science/ASCR Bob Meisner, Defense Programs/ASC Briefing to the Secretary of Energy Advisory Board, September 13, 2013 The Department of Energy is planning for a major computer and computational science initiative anchored in our mission challenges. We use the term 'exascale' to capture the successful transition to the next era of computing in the 2020 timeframe. Change is coming in many ways, not just technology. For instance: World we were in World we are going to Processing/ Processing expensive/ Processing free/ Memory: memory free memory expensive Ecosystem US micro-electronics Globalization of supply chain

476

DOE Roadmap: Chapter 2  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

2. Narratives and Records Series Descriptions 2. Narratives and Records Series Descriptions Introduction This chapter contains two kinds of information. The first consists of brief narrative histories that discuss the involvement of the Department of Energy (DOE) and its predecessor agencies with human radiation experiments. These histories cover agency headquarters elements and the various field sites that had significant involvement in experiment activities. The second category of information is series descriptions for groups of original records that are pertinent to either individual experiments or to the organizational context in which they took place. Since many of these records still reside at DOE sites, series descriptions are appended to the narrative for each facility. Where records are not in the custody of DOE, they are listed under their custodial organization (such as the National Archives).

477

DOE/EIS-0380  

Broader source: Energy.gov (indexed) [DOE]

1 1 FISCAL YEAR 2011 MITIGATION ACTION PLAN ANNUAL REPORT FOR THE 2008 LOS ALAMOS NATIONAL LABORATORY SITE-WIDE ENVIRONMENTAL IMPACT STATEMENT APRIL 2012 LOS ALAMOS SITE OFFICE 3747 West Jemez Road, MS A-316 Los Alamos, New Mexico 87545 DISCLAIMER: This document was prepared by Los Alamos National Security, LLC (LANS) in their role as management and operations (M&O) contractor for the Los Alamos National Laboratory, under contract to DOE/NNSA (Contract Number DE-AC52-06NA25396). DOE/NNSA LASO has reviewed this document for content and accuracy. The National Environmental Policy Act (NEPA) Compliance Officer for DOE/NNSA LASO concurs with this document. LA-UR-11-06159 Approved for public release; distribution is unlimited.

478

DOE Hydrogen Program Overview  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Fuel Cells and Fuel Cells Mark Paster U.S. Department of Energy Hydrogen, Fuel Cells and Infrastructure Program January, 2005 A Bold New Approach is Required 0 4 8 12 16 20 24 28 32 1970 1980 1990 2000 2010 2020 2030 2040 2050 Petroleum (MMB/Day Oil Equivalent) Actual Projection U.S. Oil Production EIA 2003 Base Case Extended Oil Consumption With Average Fuel Efficiency Automobile & Light Truck Oil Use U.S. Transportation Oil Consumption U.S. Refinery Capacity Source: DOE/EIA, International Petroleum Statistics Reports, April 1999; DOE/EIA 0520, International Energy Annual 1997, DOE/EIA0219(97), February 1999. 0 20 40 60 80 100 Rest of World OPEC US Percentage of Total Consumption Production Reserves 2% 12% 26% 7% 41% 77% 67% 47% 21% World Oil Reserves are Consolidating in OPEC Nations 0 10 20 30 40 50 60 70 80

479

DOE NEPA Compliance Officers  

Broader source: Energy.gov (indexed) [DOE]

NEPA Compliance Officers NEPA Compliance Officers NEPA Compliance Officers are listed first for Program Offices, then Power Marketing Administrations, then Field Offices. Please send updates to yardena.mansoor@hq.doe.gov Oct 04, 2013 Forrestal (FORS) Addresses: Germantown (GTN) Addresses: 1000 Independence Ave SW 1000 Independence Ave SW Washington, DC 20585 Washington, DC 20585-1290 . Use for U.S. Postal Service mail. 19901 Germantown Road Germantown, MD 20874-1290 Use for EXPRESS DELIVERY (e.g. Federal Express, UPS). NAME, OFFICE, E-MAIL FAX ADDRESS PHONE william.bierbower@hq.doe.gov Advanced Research Projects Agency-Energy 202-287-6585 FORS AR-1 20585 ARPA-E William Bierbower lori.gray@go.doe.gov Energy Efficiency and Renewable Energy, Golden Field Office 720-356-1568 720-356-1350 Department of Energy

480

DOE F 284  

Broader source: Energy.gov (indexed) [DOE]

DOE-284 DOE-284 (10-88) MANDATORY DATA COLLECTION AUTHORIZED BY Public Laws 83-703, 93-438 Previous editions are obsolete. OMB CONTROL NO. 1910-1800 Public Reporting Notice Disclosure on Back NUCLEAR MATERIAL TRANSFER REPORT NUCLEAR MATERIAL ON TRANSFER SHIPPING DATE MATERIAL HAS BEEN VERIFIED AS FOLLOWS (CHECH ONE): DATE RECEIVED FROM (RIS) PIECE COUNT OTHER: SHIPPER'S WEIGHTS AND NUCLEAR MATERIAL CONTENTS ARE ACCEPTED PENDING FINAL VERIFICATION MEASUREMENTS AND COMPLETION OF DOE/NRC FORM 741 CONTAINER COUNT BY (ACCOUNTABILITY REPRESENTATIVE) (See instructions for provisions regarding confidentiality.) GROSS WEIGHT CHECK TO (RIS) NO. U.S. DEPARTMENT OF ENERGY 18. U.S.C., SECTION 1001, ACT OF JUNE 25, 1948; 62 STAT. 749, MAKES IT A CRIMINAL OFFENSE TO MAKE A WILLFULLY FALSE STATEMENT OR REPRESENTATION TO ANY DEPARTMENT

Note: This page contains sample records for the topic "doe orders aerosys" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

DOE | OpenEI  

Open Energy Info (EERE)

DOE DOE Dataset Summary Description Source EERE Date Released September 27th, 2010 (4 years ago) Date Updated September 27th, 2010 (4 years ago) Keywords buildings commercial buildings DOE energy use Data application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon New construction (xlsx, 277.8 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon Post-1980 construction (in or after 1980) (xlsx, 277.9 KiB) application/vnd.openxmlformats-officedocument.spreadsheetml.sheet icon Pre-1980 construction (xlsx, 253 KiB) Quality Metrics Level of Review Some Review Comment Temporal and Spatial Coverage Frequency Time Period License License Open Data Commons Public Domain Dedication and Licence (PDDL) Comment Rate this dataset Usefulness of the metadata

482

GREENING DOE HEADQUARTERS  

Broader source: Energy.gov (indexed) [DOE]

- - a,- p^A CU ^ ^JL\ CC6p^ w b A GREENING DOE HEADQUARTERS Office of Management, November 2008 The DOE Headquarters Forrestal and Germantown buildings have award-winning energy conservation and environmental quality programs focused on making our buildings as green as possible and, enabling them to serve as showcases for the entire Department. Both the Forrestal and the Germantown facilities have earned EPA's Energy Star designation, ranking them among the nation's top buildings in terms of energy performance. Of all the buildings in the U.S. only approximately 4000 have earned this distinction. In addition, the Forrestal Building is one of only two Federal Energy Star Buildings in Washington DC. DOE Headquarters achieved these designations after years of effort by the facility managers and staffs to incorporate energy

483

Maxlite: Order (2010-CE-2701) | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Maxlite: Order (2010-CE-2701) Maxlite: Order (2010-CE-2701) Maxlite: Order (2010-CE-2701) In the Matter of Maxlite, SK America, Inc. (general service flourescent lamps), DOE Case Number 2010-CE-2701, Adopting Order and Compromise Agreement. Order adopting accompanying Compromise Agreement. DOE found that Maxlite failed to submit compliance certifications for its products under 10 C.F.R. Section 430.62, and here assesses a civil penalty of $5,000 (if paid within 30 days) or of $10,000 (if paid between 31-60 days). Maxlite promises to certify all products sold in the US within 60 days, and agrees to a penalty of $150 per product per day over that deadline. In exchange, DOE will accept the penalty payment, issue the adopting order, and cease enforcement action. Maxlite: Order (2010-CE-2701)

484

R-Cold: Order (2013-CE-5354)  

Broader source: Energy.gov [DOE]

DOE ordered R-Cold, Inc. to pay a $8,000 civil penalty after finding R-Cold had failed to certify that any basic models of walk-in cooler or freezer components comply with the applicable energy conservation standards.

485

North Star Refrigerator: Order (2013-CE-5355)  

Broader source: Energy.gov [DOE]

DOE ordered North Star Refrigerator Co., Inc. to pay a $8,000 civil penalty after finding North Star Refrigerator had failed to certify that any basic models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

486

Lutron Electronics: Order (2012-SE-3796)  

Broader source: Energy.gov [DOE]

DOE ordered Lutron Electronics Co., Inc. to pay a $13,000 civil penalty after finding Lutron Electronics had manufactured and distributed in commerce in the U.S. at least 79,000 units of various basic models, noncompliant Class A external power supplies.

487

Thermo Products: Order (2011-SE-1603)  

Broader source: Energy.gov [DOE]

DOE ordered Thermo Products, LLC, to pay a $6,000 civil penalty after finding Thermo Products had failed to conduct the required testing to certify that certain models of central air conditioning heat pumps comply with the applicable energy conservation standard.

488

American Cooler Technologies: Order (2013-CE-5305)  

Broader source: Energy.gov [DOE]

DOE ordered American Cooler Technologies to pay a $8,000 civil penalty after finding American Cooler Technologies had failed to certify that certain models of walk-in coolers or freezers (WICF) components comply with the applicable energy conservation standards.

489

Heat Controller: Order (2014-SE-15004)  

Broader source: Energy.gov [DOE]

DOE ordered Heat Controller, Inc. to abide by the terms of a February 11, 2014 Notice of Noncompliance Determination, after finding Heat Controller had privately labeled and distributed in commerce in the U.S. at least 7,314 noncompliant units of Comfort-Aire branded room air conditioner models CGREG-81H and REG-81J.

490

Kingspan Insulated Panels: Order (2013-CE-5353)  

Broader source: Energy.gov [DOE]

DOE ordered Kingspan Insulated Panels, Inc. to pay a $8,000 civil penalty after finding Kingspan Insulated Panels had failed to certify that any basic models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

491

Parsons Infrastructure & Technology Group, Inc., Consent Order | Department  

Broader source: Energy.gov (indexed) [DOE]

Parsons Infrastructure & Technology Group, Inc., Consent Order Parsons Infrastructure & Technology Group, Inc., Consent Order Parsons Infrastructure & Technology Group, Inc., Consent Order "The Office of Health, Safety and Security's Office of Enforcement has completed its investigation into the facts and circumstances associated with construction deficiencies at the Salt Waste Processing Facility (SWPF) located at the U.S. Department of Energy (DOE) Savannah River Site. The investigation addressed specific areas of potential noncompliance with DOE nuclear safety requirements established in 10 C.F.R. Part 830, Nuclear Safety Management." Consent Order, Parsons Infrastructure & Technology Group, Inc. - NCO-2010-02 More Documents & Publications Consent Order, Parsons Infrastructure & Technology Group, Inc. -

492

Implementing Executive Order 13423  

Broader source: Energy.gov [DOE]

Guide describes the instructions on the requirements and how fleets should implement the Executive Order 13423.

493

Mirant Reply to Comments re Special Environmental Analysis, DOE/SEA-04  

Broader source: Energy.gov (indexed) [DOE]

Reply to Comments re Special Environmental Analysis, Reply to Comments re Special Environmental Analysis, DOE/SEA-04 Potomac River Generating Station Mirant Reply to Comments re Special Environmental Analysis, DOE/SEA-04 Potomac River Generating Station Docket No. EO-05-01: On behalf of Mirant Potomac River LLC ("Mirant"), we respectfully request the opportunity to respond to certain written comments received by the Department of Energy in connection with the Department's Special Environmental Analysis dated November 2006 (DOE/SEA-04, the "SEA")) regarding DOE Order 202-05-03 ("DOE Order"), as extended by DOE Order 202-06-2 and DOE Order 202-06-2A, concerning the operations of the Potomac River Generating Station (the "Plant"). Mirant Reply to Comments re Special Environmental Analysis, DOE/SEA-04

494

DOE Directives | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

DOE Directives DOE Directives DOE Directives Directives are the Department of Energy's primary means to communicate and institutionalize directives and policies and to establish requirements, responsibilities, and procedures for Departmental elements and contractors. DOE O 413.3A - Program and Project Management for the Acquisition of Capital Assets DOE G 413.3-1 - Managing Design and Construction Using Systems Engineering for Use with DOE O 413.3A DOE G 413.3-2 - Quality Assurance Guide for Project Management DOE G 413.3-3 - Safeguards and Security for Program and Project Management DOE G 413.3-8 - Environmental Management (EM) Cleanup Projects DOE G 413.3-9 - U.S. Department of Energy Project Review Guide for Capital Asset Projects DOE G 413.3-10 - Earned Value Management System (EVMS)

495

DOE Home Offices & Facilities About DOE Press Room q Highlights  

E-Print Network [OSTI]

SEARCH DOE Home Offices & Facilities About DOE Press Room q Highlights q Press Releases q DOE strategies and biotechnologies for cleaning up groundwater at DOE and at industry sites." The contamination've provided a comprehensive picture that has led to fundamental changes in how scientists evaluate

Lovley, Derek

496

DOE-STD-1021-93 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

1-93 1-93 DOE-STD-1021-93 April 08, 2002 Natural Phenomena Hazards Performance Categorization Guidelines for Structures, Systems, and Components Replaced by DOE-STD-1020-2012 | Change Notice No. 1 (January 1996) | Reaffirmed with Errata (April 2002) The purpose of this standard is as follows: (a) To provide, for the purpose of Natural Phenomena Hazard (NPH) design and evaluation, criteria for selecting performance categories (PCs) of structures, systems, and components (SSCs) in accordance with the requirements specified in DOE Order 420.1 (Reference 10) and the NPH Guide to DOE O 420.1 (DOE G 420.1-2) (Reference 11). DOE-STD-1021-93, Natural Phenomena Hazards Performance Categorization Guidelines for Structures, Systems, and Components, Replaced by DOE-STD-1020-2012

497

Code of Federal Regulations Procedural Rules for DOE Nuclear Activities  

Broader source: Energy.gov (indexed) [DOE]

Code of Federal Regulations Procedural Rules for DOE Nuclear Code of Federal Regulations Procedural Rules for DOE Nuclear Activities Part II Code of Federal Regulations Procedural Rules for DOE Nuclear Activities Part II The Department of Energy (DOE) is issuing procedural rules to be used in applying its substantive regulations and orders relating to nuclear safety. These procedural rules are intended to be an essential part of the framework through which DOE deals with its contractors, subcontractors, and suppliers to ensure its nuclear facilities are operated in a manner that protects public and worker safety and the environment. In particular, this part sets forth the procedures to implement the provisions of the Price- Anderson Amendments Act of 1988 (PAAA) which subjects DOE contractors to potential civil and criminal penalties for violations of DOE rules,

498

FAQS Job Task Analyses - DOE AVIATION MANAGER (AvM)  

Broader source: Energy.gov (indexed) [DOE]

MANAGER (AvM) - JOB TASK ANALYSIS MANAGER (AvM) - JOB TASK ANALYSIS Job Analysis Worksheet for Tasks DOE AVIATION MANAGER Task Source Importance Frequency A Establishes goals for the field aviation program based on the anticipated requirements as applicable to DOE/NNSA, the field element, and other DOE/NNSA organizations that may require aviation services. DOE O 440.2C, chng 1 5 1 B Implements DOE/NNSA aviation management and safety policy and establishes the field element's standards for the aviation program that will ensure an effective, safe, secure and cost-efficient operation in accordance with this Order. DOE O 440.2C, chng 1 5 2 C Develops the organization's Aviation Implementation Documents (AID) and annually reviews the AID to ensure that it is current. DOE O 440.2C, chng 1 5 1

499

DOE-DP-STD-3016-99 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

DP-STD-3016-99 DP-STD-3016-99 DOE-DP-STD-3016-99 February 26, 1999 DOE-DP-STD-3016-99: Limited Standard; Hazard Analysis Reports for Nuclear Explosive Operations Replaced by DOE-NA-3016-2006 This technical standard applies to the conduct of hazard analyses and preparation of hazard analysis reports (HARs) for nuclear explosive operations (NEOs) conducted by the Department of Energy (DOE). This standard addresses operation-specific HARs and their interface with facility safety basis documents (Safety Analysis Reports [SARs] or other DOE-approved safety basis documents). DOE-DP-STD-3016-99, Limited Standard; Hazard Analysis Reports for Nuclear Explosive Operations More Documents & Publications Technical Standards, DOE Orders and Applicable CFRs/DEAR Crosswalk - February 2, 2002

500

DOE-HDBK-1204-97 | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

4-97 4-97 DOE-HDBK-1204-97 July 26, 2005 Guide to Good Practices for the Development of Test Items Supersedes DOE-STD-1009-92 (July 1992) While the methodology used in developing test items can vary significantly, to ensure quality examinations, test items should be developed systematically. Test design and development is discussed in the DOE Guide to Good Practices for Design, Development, and Implementation of Examinations. DOE-HDBK-1204-97, Guide to Good Practices for the Development of Test Items More Documents & Publications Order Module--DOE-HDBK-1203-97, GUIDE TO GOOD PRACTICES FOR TRAINING OF TECHNICAL STAFF AND MANAGERS, DOE-HDBK-1204-97, GUIDE TO GOOD PRACTICES FOR THE DEVELOPMENT OF TEST ITEMS,DOE-HDBK-1205-97, GUIDE TO GOOD PRACTICES FOR THE DESIGN, DEVELOPMENT