Sample records for district port code

  1. The Potential for Biomass District Energy Production in Port Graham, Alaska

    SciTech Connect (OSTI)

    Charles Sink, Chugachmiut; Keeryanne Leroux, EERC

    2008-05-08T23:59:59.000Z

    This project was a collaboration between The Energy & Environmental Research Center (EERC) and Chugachmiut – A Tribal organization Serving the Chugach Native People of Alaska and funded by the U.S. Department of Energy (DOE) Tribal Energy Program. It was conducted to determine the economic and technical feasibility for implementing a biomass energy system to service the Chugachmiut community of Port Graham, Alaska. The Port Graham tribe has been investigating opportunities to reduce energy costs and reliance on energy imports and support subsistence. The dramatic rise in the prices of petroleum fuels have been a hardship to the village of Port Graham, located on the Kenai Peninsula of Alaska. The Port Graham Village Council views the forest timber surrounding the village and the established salmon industry as potential resources for providing biomass energy power to the facilities in their community. Benefits of implementing a biomass fuel include reduced energy costs, energy independence, economic development, and environmental improvement. Fish oil–diesel blended fuel and indoor wood boilers are the most economical and technically viable options for biomass energy in the village of Port Graham. Sufficient regional biomass resources allow up to 50% in annual heating savings to the user, displacing up to 70% current diesel imports, with a simple payback of less than 3 years for an estimated capital investment under $300,000. Distributive energy options are also economically viable and would displace all imported diesel, albeit offering less savings potential and requiring greater capital. These include a large-scale wood combustion system to provide heat to the entire village, a wood gasification system for cogeneration of heat and power, and moderate outdoor wood furnaces providing heat to 3–4 homes or community buildings per furnace. Coordination of biomass procurement and delivery, ensuring resource reliability and technology acceptance, and arbitrating equipment maintenance mitigation for the remote village are challenges to a biomass energy system in Port Graham that can be addressed through comprehensive planning prior to implementation.

  2. Grid porting of Bhabha scattering code through a master-worker scheme

    E-Print Network [OSTI]

    Alejandro Lorca; Jose Luis Vazquez-Poletti; Eduardo Huedo; Ignacio M. Llorente

    2009-04-01T23:59:59.000Z

    A program calculating Bhabha scattering at high energy colliders is considered for porting to the EGEE Grid infrastructure. The program code, which is a result of the aITALC project, is ported by using a master-worker operating scheme. The job submission, execution and monitoring are implemented using the GridWay metascheduler. The unattended execution of jobs turned out to be complete and rather efficient, even when pre-knowledge of the grid is absent. While the batch of jobs remains organized at the user's side, the actual computation was carried out within the phenogrid virtual organization. The scientific results support the use of the small angle Bhabha scattering for the luminosity measurements of the International Linear Collider project.

  3. Building Energy Code for the District of Columbia

    Broader source: Energy.gov [DOE]

    The DC Energy Conservation Code is updated regularly as national codes are revised or if a change is proposed by local code enforcement officials, industry, design professionals, or other...

  4. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    ","ALASKA",5,260,"CANADA",2,0,0,,,,,," " "applicationvnd.ms-excel","AMMEX INC ",1,130,"Motor Gas, Conventional, Other",3802,"PORT HURON, MI","MICHIGAN",2,260,"CANADA",6,0,0,,,,,,"...

  5. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    GL",3310,"SWEETGRASS, MT","MONTANA",4,260,"CANADA",8,0,0,,,,, 39113,"AMMEX INC ",2,130,"MOTOR GAS, CONVENTIONAL, OTHER",3802,"PORT HURON, MI","MICHIGAN",2,260,"CANADA",12,0,0,,,,,...

  6. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    ","ALASKA",5,260,"CANADA",2,0,0,,,,,," " "applicationvnd.ms-excel","AMMEX INC ",1,130,"Motor Gas, Conventional, Other",3802,"PORT HURON, MI","MICHIGAN",2,260,"CANADA",5,0,0,,,,,,"...

  7. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    Oil",3604,"INTER. FALLS,MN","MINNESOTA",2,260,"CANADA",117,4.06,20.9,"MERCURIA ENERGY TRADING ",4966,"GREEN PORT","TX","TEXAS",3 "applicationvnd.ms-excel","MICHIGAN...

  8. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    Oil",3604,"INTER. FALLS,MN","MINNESOTA",2,260,"CANADA",164,4.06,20.9,"MERCURIA ENERGY TRADING ",4966,"GREEN PORT","TX","TEXAS",3 "applicationvnd.ms-excel","MICHIGAN...

  9. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    ",3,025,"Crude Oil",3402,"NOYES, MN","MINNESOTA",2,260,"CANADA",62,3.86,21.6,"MERCURIA ENERGY TRADING ",4966,"GREEN PORT","TX","TEXAS",3 "applicationvnd.ms-excel","MERCURIA...

  10. Thermal Conductivity of SiC/Si Composites – Porting PNNL EMTA Code for Fusion Analyses

    SciTech Connect (OSTI)

    Henager, Charles H.; Nguyen, Ba Nghiep

    2013-04-19T23:59:59.000Z

    An existing modeling method, the EMTA (Eshelby-Mori-Tanaka approach) modeling approach [1], is applied to the study of SiC/SiC 2D woven composites for fusion reactor applications for the first time, to the best of our knowledge, with excellent results. We compare EMTA model results to existing thermal conductivity data for these materials and suggest that in the future this approach can be beneficial by providing us with tools to further optimize these composite materials for fusion energy applications since the EMTA method and code can address both thermal and mechanical properties with the same framework.

  11. District Coordinators District 1--Serving Baraga, Dickinson, Gogebic, Houghton, Iron, Keweenaw, Marquette, Menominee, Ontonagon

    E-Print Network [OSTI]

    , Tuscola Joseph Bixler MSU Extension District 10, 200 Grand River Ave., Suite 102, Port Huron, MI 48060 e

  12. Intake port

    DOE Patents [OSTI]

    Mendler, Edward Charles

    2005-02-01T23:59:59.000Z

    The volumetric efficiency and power of internal combustion engines is improved with an intake port having an intake nozzle, a venturi, and a surge chamber. The venturi is located almost halfway upstream the intake port between the intake valves and the intake plenum enabling the venturi throat diameter to be exceptionally small for providing an exceptionally high ram velocity and an exceptionally long and in turn high efficiency diffuser flowing into the surge chamber. The intake port includes an exceptionally large surge chamber volume for blow down of the intake air into the working cylinder of the engine.

  13. Groundwater Conservation Districts (Texas)

    Broader source: Energy.gov [DOE]

    Groundwater Conservation Districts, as created following procedures described in Water Code 36, are designed to provide for the conservation, preservation, protection, recharging, and prevention of...

  14. Texas Port eyes phased construction

    SciTech Connect (OSTI)

    Not Available

    1980-01-21T23:59:59.000Z

    The Texas Deepwater Port Authority might be built piecemeal since only seven companies have made nonbinding expressions to supply throughput of 550,000 bbl/day for the port. The Port Authority needs commitments for 1.4 million bbl/day from shippers before it could sell bonds to finance the $843 million construction cost of the originally planned 2.5 million bbl/day facility. The Louisiana Offshore Oil Port Inc. (LOOP) project will be finished during the first quarter of 1981, rather than during the originally scheduled fourth quarter of 1980, due to the greater than expected time required for drilling and leaching of salt domes for crude storage. Environmental concerns engendered by the Burmah Agate fire for the Pelican Terminal Corporation near Galveston, Texas. The Nueces County Navigation District Deeport project in the Corpus Christi area, which calls for the dredging of an 80 ft deep, 10 mi long approach channel as well as docking and turning basins, is being delayed out of concern that the dredging spoils would damage wetlands.

  15. Remote USB Ports

    E-Print Network [OSTI]

    Roshan, Rakesh

    2013-10-01T23:59:59.000Z

    or actuator placed in fields can be accessed by a system remotely and securely. In this thesis, we propose a remote USB port, which is an abstraction of a USB port. In the USB core driver of the server machine, with the hub information, port status of all...

  16. Susanville District Heating District Heating Low Temperature...

    Open Energy Info (EERE)

    Susanville District Heating District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Susanville District Heating District Heating Low Temperature...

  17. Porting the NAS-NPB Conjugate Gradient

    E-Print Network [OSTI]

    Crawford, T. Daniel

    .kr/Center_for_Manycore_Programming/SNU_NPB_Suite.html NPB Benchmarks #12;! "A conjugate gradient method is used to compute an approximation to the smallestPorting the NAS-NPB Conjugate Gradient Benchmark to CUDA NVIDIA Corporation #12;Outline ! Overview coding methodologies and architectures. ! Suite of benchmarks: ! Integer Sort ! Conjugate Gradient ! CFD

  18. Port Arthur LNG

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Port Arthur LNG March 20, 2015 Submitted electronically to fersas(a)hq.doe.eov Ms. Larine A. Moore Docket Room Manager FE-34 U.S. Department of Energy P.O. Box 44375 Washington, DC...

  19. Ports, Boats and Automobiles

    E-Print Network [OSTI]

    Hall, Peter V.

    2003-01-01T23:59:59.000Z

    PORTS, BOATS, AND AUTOMOBILES B Y P E T E R V. H A L L A C Cships designed to carry automobiles. Less visible though areAlthough major automobile importers ostensibly do the same

  20. Porting salinas to the windows platform.

    SciTech Connect (OSTI)

    Reese, Garth M.; Wilson, Christopher Riley

    2006-06-01T23:59:59.000Z

    The ASC program has enabled significant development of high end engineering applications on massively parallel machines. There is a great benefit in providing these applications on the desktop of the analysts and designers, at least insofar as the small models may be run on these platforms, thus providing a tool set that spans the application needs. This effort documents the work of porting Salinas to the WINDOWS{trademark} platform. Selection of the tools required to compile, link, test and run Salinas in this environment is discussed. Significant problems encountered along the way are listed along with an estimation of the overall cost of the port. This report may serve as a baseline for streamlining further porting activities with other ASC codes.

  1. Groundwater Conservation Districts: Success Stories

    E-Print Network [OSTI]

    Porter, Dana; Persyn, Russell A.; Enciso, Juan

    1999-09-06T23:59:59.000Z

    these limited resources is increasing, so our aquifers must be conserved and protected for the benefit of the state?s economy, our natural ecosystems, and our quality of life. The Texas Water Code, Chapter 36, calls for the creation of Groundwater Conservation... groundwater reservoirs or their subdivisions.? In Texas, local deci- sion making through Groundwater Conservation Districts has been the rule and not the exception. In fact, Groundwater Conservation Districts are the state?s preferred method of groundwater...

  2. DECONTAMINATION OF DREDGED MATERIAL FROM PORT OF NY/NJ DECONTAMINATION OF DREDGED MATERIAL FROM THE PORT OF

    E-Print Network [OSTI]

    Brookhaven National Laboratory

    District, CENAN-PL-ES, 26 Federal Plaza, New York, NY 10278-0090 4 Department of Environmental and Energy THE PORT OF NEW YORK AND NEW JERSEY 1 K. W. Jones, 2 E. A. Stern, 3 K. R. Donato, 4 N. L. Clesceri 1 - Region 2 - DEPP-PBPB, 290 Broadway, New York, NY 10007-1866 3 US Army Corps of Engineers - New York

  3. Water Control and Improvement Districts (Texas)

    Broader source: Energy.gov [DOE]

    The Texas Commission on Environmental Quality is authorized to review and establish local water districts throughout the state of Texas. The Water Code gives the Commission the right of...

  4. Regional Districts (Texas)

    Broader source: Energy.gov [DOE]

    Adjacent Water Control and Improvement Districts and Municipal Utility Districts can opt to form a Regional District to oversee water issues. Such districts may be created:(1) to purchase, own,...

  5. Multi-port valve

    DOE Patents [OSTI]

    Lewin, Keith F. (Calverton, NY)

    1997-04-15T23:59:59.000Z

    A multi-port valve for regulating, as a function of ambient air having varying wind velocity and wind direction in an open-field control area, the distribution of a fluid, particularly carbon dioxide (CO.sub.2) gas, in a fluid distribution system so that the control area remains generally at an elevated fluid concentration or level of said fluid. The multi-port valve generally includes a multi-port housing having a plurality of outlets therethrough disposed in a first pattern of outlets and at least one second pattern of outlets, and a movable plate having a plurality of apertures extending therethrough disposed in a first pattern of apertures and at least one second pattern of apertures. The first pattern of apertures being alignable with the first pattern of outlets and the at least one second pattern of apertures being alignable with the second pattern of outlets. The first pattern of apertures has a predetermined orientation with the at least one second pattern of apertures. For an open-field control area subject to ambient wind having a low velocity from any direction, the movable plate is positioned to equally distribute the supply of fluid in a fluid distribution system to the open-field control area. For an open-field control area subject to ambient wind having a high velocity from a given direction, the movable plate is positioned to generally distribute a supply of fluid in a fluid distribution system to that portion of the open-field control area located upwind.

  6. Multi-port valve

    DOE Patents [OSTI]

    Lewin, K.F.

    1997-04-15T23:59:59.000Z

    A multi-port valve is described for regulating, as a function of ambient air having varying wind velocity and wind direction in an open-field control area, the distribution of a fluid, particularly carbon dioxide (CO{sub 2}) gas, in a fluid distribution system so that the control area remains generally at an elevated fluid concentration or level of said fluid. The multi-port valve generally includes a multi-port housing having a plurality of outlets there through disposed in a first pattern of outlets and at least one second pattern of outlets, and a movable plate having a plurality of apertures extending there through disposed in a first pattern of apertures and at least one second pattern of apertures. The first pattern of apertures being alignable with the first pattern of outlets and the at least one second pattern of apertures being alignable with the second pattern of outlets. The first pattern of apertures has a predetermined orientation with the at least one second pattern of apertures. For an open-field control area subject to ambient wind having a low velocity from any direction, the movable plate is positioned to equally distribute the supply of fluid in a fluid distribution system to the open-field control area. For an open-field control area subject to ambient wind having a high velocity from a given direction, the movable plate is positioned to generally distribute a supply of fluid in a fluid distribution system to that portion of the open-field control area located upwind. 7 figs.

  7. Elko County School District District Heating Low Temperature...

    Open Energy Info (EERE)

    Elko County School District District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Elko County School District District Heating Low Temperature...

  8. San Bernardino District Heating District Heating Low Temperature...

    Open Energy Info (EERE)

    San Bernardino District Heating District Heating Low Temperature Geothermal Facility Facility San Bernardino District Heating Sector Geothermal energy Type District Heating...

  9. Warm Springs Water District District Heating Low Temperature...

    Open Energy Info (EERE)

    Water District District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Warm Springs Water District District Heating Low Temperature Geothermal...

  10. Philip District Heating District Heating Low Temperature Geothermal...

    Open Energy Info (EERE)

    Philip District Heating District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Philip District Heating District Heating Low Temperature Geothermal...

  11. Boise City Geothermal District Heating District Heating Low Temperatur...

    Open Energy Info (EERE)

    Boise City Geothermal District Heating District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Boise City Geothermal District Heating District Heating...

  12. Pagosa Springs District Heating District Heating Low Temperature...

    Open Energy Info (EERE)

    Pagosa Springs District Heating District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Pagosa Springs District Heating District Heating Low...

  13. Midland District Heating District Heating Low Temperature Geothermal...

    Open Energy Info (EERE)

    Midland District Heating District Heating Low Temperature Geothermal Facility Facility Midland District Heating Sector Geothermal energy Type District Heating Location Midland,...

  14. Kethcum District Heating District Heating Low Temperature Geothermal...

    Open Energy Info (EERE)

    Kethcum District Heating District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Kethcum District Heating District Heating Low Temperature Geothermal...

  15. DistrictHeating Nuevasaladecalderasydistribucin

    E-Print Network [OSTI]

    Fraguela, Basilio B.

    DistrictHeating Nuevasaladecalderasydistribución decaloreneláreauniversitariade AZapateira Jesús, difusión. DISTRICT HEATING O CALEFACCIÓN DE BARRIO #12;MATERIALIZACIÓN INTEGRACIÓN VISUAL DE ELEMENTOS rendimiento global de la instalación. - Contabilización de pérdidas en tuberías de distribución. #12;DISTRICT

  16. Conservation Districts (South Dakota)

    Broader source: Energy.gov [DOE]

    A Conservation District can be established by petition of registered voters within the territory proposed for organization into the district, with the approval of the State Conservation Commission....

  17. Natural Resources Districts (Nebraska)

    Broader source: Energy.gov [DOE]

    This statute establishes Natural Resources District, encompassing all of the area of the state, to conserve, protect, develop, and manage Nebraska's natural resources. These districts replace and...

  18. Evaluation of Dredged Material Proposed for Ocean Disposal from Port Chester, New York

    SciTech Connect (OSTI)

    Barrows, E.S.; Mayhew, H.L.; Word, J.Q.; Tokos, J.J.S. [Battelle Marine Sciences Laboratory, Sequim, WA (United States)

    1996-08-01T23:59:59.000Z

    Port Chester was one of seven waterways that the US Army Corps of Engineers-New York District requested the Battelle Marine Sciences Laboratory to sample and evaluate for dredging and disposal in March 1994. Tests and analyses were conducted on Port Chester sediment core samples. Because the Port Chester area is located on the border between New York and southeast Connecticut, its dredged material may also be considered for disposal at the Central Long Island Sound Disposal Site. The sediment evaluation consisted of bulk sediment chemical analyses, chemical analyses of site water and dredged material elutriate preparations, water-column and benthic acute toxicity tests, and bioaccumulation studies. Individual sediment core samples collected from Port Chester were analyzed for grain size, moisture content, and total organic carbon. In addition, sediment was analyzed for bulk density, specific gravity, metals, chlorinated pesticides, polychlorinated biphenyl congers, polynuclear aromatic hydrocarbons and 1,4-dichlorobenzene.

  19. Corpus Christi oil port eyed

    SciTech Connect (OSTI)

    Powers, M.B.

    1993-07-05T23:59:59.000Z

    The Port of Corpus Christi, Texas, with the support of several oil companies and the blessing of the US Coast Guard, plans to build a $600-million deepwater harbor to accommodate supertankers. The proposed port, Safeharbor, is touted as an environmentally sound solution to current risks associated with off-loading crude oil from very large tankers at shore ports. In a system called lightering, crude now is transferred from supertankers in deep water to smaller vessels that can negotiate shallow channels. While smaller tankers need only 45 ft of water, supertankers need 80 ft. Corpus Christi has the advantage of being closer to deep water than other Gulf ports, but nevertheless, half the proposed project's cost, $300 million, would be for dredging a 10-mile channel to deep water.

  20. Port security and information technology

    E-Print Network [OSTI]

    Petrakakos, Nikolaos Harilaos

    2005-01-01T23:59:59.000Z

    The terrorist attacks of September 11th 2001 on New York and Washington DC shed light on the many security shortcomings that sea ports and the entire import and export process face. A primary source of these problems is ...

  1. The Enviro-Port concept 

    E-Print Network [OSTI]

    McNutt, William Carl

    1977-01-01T23:59:59.000Z

    . . . . . . 82 Enviro-Port Si te Sel ection I"patri x . . . . . . . 92 LIST OF F IGURES Oil Spills by County, January 1973- November 1974 . Causes of Spills by Incident and Volume . quantity of Oil SpiIled by Cause- January 1973 - November 1974... and controlled by design in the initial Enviro-Port concept. These five specific types of pollution are oil discharges, hazardous material discharges, industrial wastes, non-point source wastes, and ship wastes. Oil Discharges and Accidenta] Spills According...

  2. Economic Improvement Districts (Indiana)

    Broader source: Energy.gov [DOE]

    A legislative body may adopt an ordinance establishing an economic improvement district and an Economic Improvement Board to manage development in a respective district. The Board can choose to...

  3. INLAND PORT TRANSPORTATION EVALUATION GUIDE

    E-Print Network [OSTI]

    Texas at Austin, University of

    INLAND PORT TRANSPORTATION EVALUATION GUIDE by Robert Harrison, Center for Transportation Research Transportation Institute, The Texas A&M University System; and Jolanda Prozzi, Center for Transportation Research, The University of Texas at Austin CENTER FOR TRANSPORTATION RESEARCH Bureau of Engineering Research

  4. Municipal Utility Districts (Texas)

    Broader source: Energy.gov [DOE]

    Municipal Utility Districts, regulated by the Texas Commission on Environmental Quality, may be created for the following purposes: (1) the control, storage, preservation, and distribution of its...

  5. Tri-Cities Research District A place to do business and thrive

    E-Print Network [OSTI]

    Northwest National Laboratory (PNNL), the Port of Benton, and other economic development partners have of land surrounding the PNNL campus » Currently home to 80+ tenants that employ more than 8,000 people-mail: Gary.Spanner@pnnl.gov http://www.pnnl.gov/edo/opportunities/research_ district.stm November 2012 PNNL

  6. Kurucz's codes under GNU-Linux

    E-Print Network [OSTI]

    L. Sbordone

    2005-09-13T23:59:59.000Z

    We report on the latest version of our GNU-Linux port of the ATLAS - SYNTHE - WIDTH suite of codes for the stellar atmosphere modeling. The latest version (8.1 at the time of the workshop) of the Intel Fortran Compiler allowed for a significantly better backward compatibility with the VMS version of the code, thus allowing us to remove almost all the modifications we initially introduced in order to compile the code under IFC. We now provide ported versions both of ATLAS 9 (the ODF version of ATLAS) and ATLAS 12 (the opacity sampling version). A comprehensive website has been created to host the ported codes, along with a growing body of documentation and resources. Also, three mailing lists have been created at the university of Ljubljana in order to cover general usage, code development and ATLAS-related announcements.

  7. The Enviro-Port concept

    E-Print Network [OSTI]

    McNutt, William Carl

    1977-01-01T23:59:59.000Z

    of Advisory Committee: Dr. Roy W. Harm, Jr. Basic information on the environmental aspects and problems of por'. -industrial complexes is reviewed and discussed. This informati on is based on first a review of selected case studies of existing Texas po. ts... of these systems are causing them to be viewed as an alternative to be considered in the future of Texas and the rest of the Nation. Thesis Objectives The thesis objective is to develop the Enviro-Port concept. This concept will include expanded environmental...

  8. ports | National Nuclear Security Administration

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilAElectronic Input Options Gary L. HirschOccurrencei-rapter | ¡ ¢ £ports |

  9. City of Klamath Falls District Heating District Heating Low Temperatur...

    Open Energy Info (EERE)

    Geothermal Facility Jump to: navigation, search Name City of Klamath Falls District Heating District Heating Low Temperature Geothermal Facility Facility City of Klamath Falls...

  10. Measuring the capacity of a port system : a case study on a Southeast Asian port

    E-Print Network [OSTI]

    Salminen, Jason Bryan

    2013-01-01T23:59:59.000Z

    As economies develop and trade routes change, investment in port infrastructure is essential to maintain the necessary capacity for an efficiently functioning port system and to meet expected demand for all types of cargo. ...

  11. Economic Development Project Districts (Indiana)

    Broader source: Energy.gov [DOE]

    Redevelopment commissions may petition legislative bodies to designate economic development project districts in cities with populations between 80,500 and 500,000. Such districts may be...

  12. Entry/Exit Port testing, test report

    SciTech Connect (OSTI)

    Winkelman, R.H.

    1993-05-01T23:59:59.000Z

    The Waste Receiving and Processing Module I (WRAP-1) facility must have the ability to allow 55-gallon drums to enter and exit glovebox enclosures. An Entry/Exit Port (Appendix 1, Figure 1), designed by United Engineers and Constructors (UE&C), is one method chosen for drum transfer. The Entry/Exit Port is to be used for entry of 55-gallon drums into both process entry gloveboxes, exit of 55-gallon drum waste pucks from the low-level waste (LLW) glovebox, and loadout of waste from the restricted waste management glovebox. The Entry/Exit Port relies on capture velocity air flow and a neoprene seal to provide alpha confinement when the Port is in the open and closed positions, respectively. Since the glovebox is in a slight vacuum, air flow is directed into the glovebox through the space between the overpack drum and glovebox floor. The air flow is to direct any airborne contamination into the glovebox. A neoprene seal is used to seal the Port door to the glovebox floor, thus maintaining confinement in the closed position. Entry/Exit Port testing took place February 17, 1993, through April 14, 1993, in the 305 building of Westinghouse Hanford Company. Testing was performed in accordance with the Entry/Exit Port Testing Test Plan, document number WHC-SD-WO26-TP-005. A prototype Entry/Exit Port built at the Hanford Site was tested using fluorescent paint pigment and smoke candles as simulant contaminants. This test report is an interim test report. Further developmental testing is required to test modifications made to the Port as the original design of the Port did not provide complete confinement during all stages of operation.

  13. Updated January 2014 District Coordinators

    E-Print Network [OSTI]

    , Lapeer, Sanilac, St. Clair, Tuscola Joseph Bixler MSU Extension District 10, 200 Grand River Ave., Suite

  14. Rotary sequencing valve with flexible port plate

    DOE Patents [OSTI]

    Wagner, Glenn Paul

    2005-05-10T23:59:59.000Z

    Rotary sequencing valve comprising a rotor having a rotor face rotatable about an axis perpendicular to the rotor face, wherein the rotor face has a plurality of openings, one or more of which are disposed at a selected radial distance from the axis, and wherein the rotor includes at least one passage connecting at least one pair of the plurality of openings. The valve includes a flexible port plate having a first side and a second side, wherein the first side faces the rotor and engages the rotor such that the flexible port plate can be rotated coaxially by the rotor and can move axially with respect to the rotor, wherein the flexible port plate has a plurality of ports between the first and second sides, which ports are aligned with the openings in the rotor face. The valve also includes a stator having a stator face disposed coaxially with the rotor and the flexible port plate, wherein the second side of the flexible port plate is in sealable, slidable rotary contact with the stator face, wherein the stator face has a plurality of openings, some of which are disposed at the selected radial distance from the axis, and wherein the plurality of openings extend as passages through the stator. The valve may be used in pressure or temperature swing adsorption systems.

  15. Multi-port valve assembly

    DOE Patents [OSTI]

    Guggenheim, S. Frederic (Teaneck, NJ)

    1986-01-01T23:59:59.000Z

    A multi-port fluid valve apparatus is used to control the flow of fluids through a plurality of valves and includes a web, which preferably is a stainless steel endless belt. The belt has an aperture therethrough and is progressed, under motor drive and control, so that its aperture is moved from one valve mechanism to another. Each of the valve mechanisms comprises a pair of valve blocks which are held in fluid-tight relationship against the belt. Each valve block consists of a block having a bore through which the fluid flows, a first seal surrounding the bore and a second seal surrounding the first seal, with the distance between the first and second seals being greater than the size of the belt aperture. In order to open a valve, the motor progresses the belt aperture to where it is aligned with the two bores of a pair of valve blocks, such alignment permitting a flow of the fluid through the valve. The valve is closed by movement of the belt aperture and its replacement, within the pair of valve blocks, by a solid portion of the belt.

  16. The probate inventories of Port Royal, Jamaica

    E-Print Network [OSTI]

    Thornton, Diana Vida

    1992-01-01T23:59:59.000Z

    THE PROBATE INVENTORIES OF PORT ROYAL, JAMAICA A Thesis by DIANA VIDA THORNTON Submitted to the Office of Graduate Studies of Texas A8cM University in partial fulfillment of the requirements for the degree of MASTER OF ARTS December 1992... Major Subject: Anthropology THE PROBATE INVENTORIES OF PORT ROYAL, JAMAICA A Thesis by DIANA VIDA THORNTON Approved as to style and content by: D. L. Hamilton, Anthropology (Chair of Committee) Kevrn Crisman, Anthropology (Member) James M...

  17. MODELING AND VERIFICATION OF AN ATM PORT CONTROLLER IN VIS

    E-Print Network [OSTI]

    Tahar, Sofiène

    MODELING AND VERIFICATION OF AN ATM PORT CONTROLLER IN VIS Jianping Lu and Sofiène Tahar Dept port controller using model checking. The ATM port controller is part of the Cambridge Fairisle ATM on the model checking of the ATM port controller using the VIS tool from UC Berkeley. To this end, we

  18. RADISSON RESORT AT THE PORT HAS SELF-ASSESSED ITS

    E-Print Network [OSTI]

    Jawitz, James W.

    PROGRAMS RADISSON RESORT AT THE PORT #12;BATTERY RECYCLING AND DISPOSAL PROGRAM RADISSON RESORT AT THE PORT #12;KITCHEN COOKING OIL RECYCLING PROGRAM RADISSON RESORT AT THE PORT #12;USES GROUNDWATER FOR COOLING ELECTRONICALLY RADISSON RESORT AT THE PORT #12;PENS AND NOTEPADS PRODUCED FROM RECYCLED MATERIALS RADISSON RESORT

  19. Cost-Effectiveness of ASHRAE Standard 90.1-2010 for the District of Columbia

    SciTech Connect (OSTI)

    Hart, Philip R.; Rosenberg, Michael I.; Xie, YuLong; Zhang, Jian; Richman, Eric E.; Elliott, Douglas B.; Loper, Susan A.; Myer, Michael

    2013-11-29T23:59:59.000Z

    Moving to the ANSI/ASHRAE/IES Standard 90.1-2010 version from the Base Code (90.1-2007) is cost-effective for all building types and climate zones in the District of Columbia.

  20. Forestry Policies (District of Columbia)

    Broader source: Energy.gov [DOE]

    Forest policy and guidelines in Washington D.C. are focused on urban forestry, and are managed by the District Department of Transportation's Urban Forestry Administration. In 2010 The District...

  1. Water Resource Districts (North Dakota)

    Broader source: Energy.gov [DOE]

    Water Resource Districts are created throughout the state of North Dakota to manage, conserve, protect, develop, and control water resources. Each District will be governed by a Water Resource...

  2. Local Water Quality Districts (Montana)

    Broader source: Energy.gov [DOE]

    This statute provides for the creation of local water quality districts to prevent and mitigate ground and surface water contamination. Each local water quality district may develop and implement a...

  3. Code Description Code Description

    E-Print Network [OSTI]

    Leave* 5127 Officials 5217 Faculty Sick Leave Payment 5124 Personal Service Contracts 5211 Research Services Contracts Scholarships & Fellowships Faculty Fringe Contract Services #12;Banner Account Code

  4. District Wide Geothermal Heating Conversion Blaine County School...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    District Wide Geothermal Heating Conversion Blaine County School District District Wide Geothermal Heating Conversion Blaine County School District This project will impact the...

  5. International District Energy Association

    Broader source: Energy.gov [DOE]

    Since its formation in 1909, the International District Energy Association (IDEA) has served as a principal industry advocate and management resource for owners, operators, developers, and suppliers of district heating and cooling systems in cities, campuses, bases, and healthcare facilities. Today, with over 1,400 members in 26 countries, IDEA continues to organize high-quality technical conferences that inform, connect, and advance the industry toward higher energy efficiency and lower carbon emissions through innovation and investment in scalable sustainable solutions. With the support of DOE, IDEA performs industry research and market analysis to foster high impact projects and help transform the U.S. energy industry. IDEA was an active participant in the original Vision and Roadmap process and has continued to partner with DOE on combined heat and power (CHP) efforts across the country.

  6. Port Royal, Jamaica, and the slave trade

    E-Print Network [OSTI]

    Johnson, David A

    2000-01-01T23:59:59.000Z

    of the eighteenth century in the Florida Keys, Henrietta Marie had just quit Port Royal after off-loading her human cargo. The artifact collection of shackles, ship's equipment and trade goods represents the trappings of the maritime slave trade. Particularly...

  7. An integrated mobile system for port security

    SciTech Connect (OSTI)

    Cester, D. [Dipartimento di Fisica, Universita di Padova, Via F. Marzolo 8, Padova I-35131 (Italy); Fabris, D. [INFN Sezione di Padova, Via F. Marzolo 8, Padova I-35131 (Italy); Lunardon, M.; Moretto, S. [Dipartimento di Fisica, Universita di Padova, Via F. Marzolo 8, Padova I-35131 (Italy); Nebbia, G. [INFN Sezione di Padova, Via F. Marzolo 8, Padova I-35131 (Italy); Pesente, S.; Stevanato, L.; Viesti, G. [Dipartimento di Fisica, Universita di Padova, Via F. Marzolo 8, Padova I-35131 (Italy); Neri, F.; Petrucci, S.; Selmi, S.; Tintori, C. [CAEN S.p.A., Via Vetraia 11, I-55049, Viareggio LU (Italy)

    2011-07-01T23:59:59.000Z

    An integrated mobile system for port security is presented. The system is designed to perform active investigations, by using the tagged neutron inspection technique, of suspect dangerous materials as well as passive measurements of neutrons and gamma rays to search and identify radioactive and special nuclear materials. (authors)

  8. Terminals and Ports Jan C. Willems

    E-Print Network [OSTI]

    Terminals and Ports Jan C. Willems ESAT, K.U. Leuven, B-3001 Leuven, Belgium Email: Jan. An electrical circuit is a device that interacts with its environment through wires, called terminals. On each terminal, there are two interaction variables, a potential and a current. Interconnection of circuits

  9. FITCH RATES PORT OF MORROW (OR) TRANSMISSION FACILITIES REV BONDS...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    FITCH RATES PORT OF MORROW (OR) TRANSMISSION FACILITIES REV BONDS 'AA'; OUTLOOK STABLE Fitch Ratings-Austin-24 November 2014: Fitch Ratings assigns 'AA' ratings to the Port of...

  10. 1District health services research: 2011 District health

    E-Print Network [OSTI]

    Geldenhuys, Jaco

    meDicine anD Primary care, faculty of meDicine anD HealtH sciences, stellenboscH university #12RoDUctIon...................................................................................................................................... clInIcal famIly meDIcIne anD DIstRIct health caRe systems1District health services research: 2011 District health services research: 2011Division of family

  11. Inland Navigation Districts and Florida Inland Navigation District Law (Florida)

    Broader source: Energy.gov [DOE]

    The first part of this legislation establishes Inland Navigation Districts, which are authorized to plan for and manage the development of inland waterways, and to maintain public navigation...

  12. Soil Conservation Districts Law (Iowa)

    Broader source: Energy.gov [DOE]

    This legislation establishes a soil and water conservation division within the Iowa Department of Agriculture, as well as local soil and water conservation districts. The regulations accompanying...

  13. UNITED STATES DISTRICT COURT EASTERN DISTRICT OF MICHIGAN

    E-Print Network [OSTI]

    Shyy, Wei

    UNITED STATES DISTRICT COURT EASTERN DISTRICT OF MICHIGAN SOUTHERN DIVISION COALITION TO DEFEND PARTY, Plaintiffs, v. JENNIFER GRANHOLM, in her official capacity as Governor of the State of Michigan, the REGENTS OF THE UNIVERSITY OF MICHIGAN, the BOARD OF TRUSTEES OF MICHIGAN STATE UNIVERSITY, the BOARD

  14. Drainage, Sanitation, and Public Facilities Districts (Virginia)

    Broader source: Energy.gov [DOE]

    This legislation provides for the establishment of sanitary, sanitation, drainage, and public facilities districts in Virginia. Designated districts are public bodies, and have the authority to...

  15. Litchfield Correctional Center District Heating Low Temperature...

    Open Energy Info (EERE)

    Correctional Center District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Litchfield Correctional Center District Heating Low Temperature Geothermal...

  16. District Energy Technologies | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Energy Technologies District Energy Technologies District energy systems produce steam, hot water, or chilled water at a central plant. Then they pipe the energy to...

  17. Spinal codes

    E-Print Network [OSTI]

    Perry, Jonathan, S.M. Massachusetts Institute of Technology

    2012-01-01T23:59:59.000Z

    Spinal codes are a new class of rateless codes that enable wireless networks to cope with time-varying channel conditions in a natural way, without requiring any explicit bit rate selection. The key idea in the code is the ...

  18. Need for port development legislation. [In support of S. 865

    SciTech Connect (OSTI)

    Joseph, M.R.

    1983-06-27T23:59:59.000Z

    The author gives testimony in support of Senate Bill S.865. US ports are a weak link in the mine-to-market chain as evidenced by the long wait to load coal for overseas customers. This weakness cost us lost revenue of over $1 billion in 1980 and 1981. Therefore the US needs legislation to upgrade ports and harbors to meet the global demand for US coal. Discussion is presented under the headings. Trends in Coal Use and Trade; the US share of the World Coal Market; Port Capacity and the Need for Deep Draft Channels in the US; the Customer Countries; the Competing Countries; the Trend Towards Larger Vessels; Legislation Proposals to Improve Coastal Ports; and National Coal Association Supports S.865 with Modifications. Appendices include data on future coal trade, port capacity, channel depth, ocean transport and shipping cost, and channel improvements at US ports. 21 tables. (DMC)

  19. Great Lakes ports coal handling capacity and export coal potential

    SciTech Connect (OSTI)

    Ames, A.H. Jr.

    1981-02-01T23:59:59.000Z

    This study was developed to determine the competitive position of the Great Lakes Region coal-loading ports in relation to other US coastal ranges. Due to the congestion at some US Atlantic coastal ports US coal producers have indicated a need for alternative export routes, including the Great Lakes-St. Lawrence Seaway System. The study assesses the regions coal handling capacity and price competitiveness along with the opportunity for increased US flag vessel service. A number of appendices are included showing major coal producers, railroad marketing representatives, US vessel operators, and port handling capacities and throughput. A rate analysis is provided including coal price at the mine, rail rate to port, port handling charges, water transportation rates to western Europe, Great Lakes route versus the US Atlantic Coast ports.

  20. Operational analysis of the Port City Stockyards

    E-Print Network [OSTI]

    Smith, Houston Edward

    1957-01-01T23:59:59.000Z

    of bwperst Port Citp StocdcPsrgst first fall weak cash montb, 195185000 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ 000 ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ ~ P~ of lkveshoeh ~ed bF tppes of bwPersc bP speoies, Perh Citp She~st first AU. weeh sash mentbt... ~ ~ ' ~ I 0 0 f ~ ~ ~ II ~ ~ 1 4 1 ~ ' f 0 e BsliverP aQey at nev trask cattle doehs+. ~ ~ . ~ i. . . . ~ . Inkivsring settle bp Ssyrsss elle@ flu new ~ settle doohs to co~0 ~ ~ I ~ 0 ~ 11 tl ~ 1 ~ ~ ~ ~ ~ 0 ~ ~ ~ ~ ~ ~ ~ ~ ~ VeighLng esXKI'at seals Coo...

  1. Compressor ported shroud for foil bearing cooling

    DOE Patents [OSTI]

    Elpern, David G. (Los Angeles, CA); McCabe, Niall (Torrance, CA); Gee, Mark (South Pasadena, CA)

    2011-08-02T23:59:59.000Z

    A compressor ported shroud takes compressed air from the shroud of the compressor before it is completely compressed and delivers it to foil bearings. The compressed air has a lower pressure and temperature than compressed outlet air. The lower temperature of the air means that less air needs to be bled off from the compressor to cool the foil bearings. This increases the overall system efficiency due to the reduced mass flow requirements of the lower temperature air. By taking the air at a lower pressure, less work is lost compressing the bearing cooling air.

  2. Vapor port and groundwater sampling well

    DOE Patents [OSTI]

    Hubbell, J.M.; Wylie, A.H.

    1996-01-09T23:59:59.000Z

    A method and apparatus have been developed for combining groundwater monitoring wells with unsaturated-zone vapor sampling ports. The apparatus allows concurrent monitoring of both the unsaturated and the saturated zone from the same well at contaminated areas. The innovative well design allows for concurrent sampling of groundwater and volatile organic compounds (VOCs) in the vadose (unsaturated) zone from a single well, saving considerable time and money. The sample tubes are banded to the outer well casing during installation of the well casing. 10 figs.

  3. Vapor port and groundwater sampling well

    DOE Patents [OSTI]

    Hubbell, Joel M. (Idaho Falls, ID); Wylie, Allan H. (Idaho Falls, ID)

    1996-01-01T23:59:59.000Z

    A method and apparatus has been developed for combining groundwater monitoring wells with unsaturated-zone vapor sampling ports. The apparatus allows concurrent monitoring of both the unsaturated and the saturated zone from the same well at contaminated areas. The innovative well design allows for concurrent sampling of groundwater and volatile organic compounds (VOCs) in the vadose (unsaturated) zone from a single well, saving considerable time and money. The sample tubes are banded to the outer well casing during installation of the well casing.

  4. Alcator C-Mod Port Space

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625govInstrumentstdmadapInactiveVisiting the TWP TWP RelatedCellulase C. bescii CelA, adefaultRuns for CY 2015 Port

  5. Microsoft BPA proposal extends Port Townsend Paper contract nine...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    is adopted. BPA is proposing to amend Port Townsend Paper Company's existing power purchase contract extending the term of the contract until September 2022,...

  6. Strategic Surveillance System Design for Ports and Waterways

    E-Print Network [OSTI]

    Cimren, Elif I.

    2010-07-14T23:59:59.000Z

    linear integer programming model to prescribe a strategic surveillance system design (SSD) for ports or waterways, to devise branch-and-price decomposition (B...

  7. Missouri School District Charges Up

    Broader source: Energy.gov [DOE]

    Missouri's Lee's Summit R-7 school district's distribution fleet was tired. Many of the vehicles had racked up more than 300,000 miles and made frequent trips to the shop to repair the 20 plus-year-old parts.

  8. UNIVERSITY OF THE DISTRICT OF

    E-Print Network [OSTI]

    District of Columbia, University of the

    UNIVERSITY OF THE DISTRICT OF COLUMBIA 1 Removal of Eutrophic Nutrients from Wastewater-Supplemented Digester Elutriate in the Fermentor 2. The Effect of Differential- Heating of Digester Elutriate on its

  9. Groundwater Conservation Districts: Success Stories 

    E-Print Network [OSTI]

    Porter, Dana; Persyn, Russell A.; Enciso, Juan

    1999-09-06T23:59:59.000Z

    Demand for water is increasing, so our aquifers must be conserved and protected. The Groundwater Conservation Districts in Texas are carrying out a number of successful programs in the areas of education and public awareness, technical assistance...

  10. Workplace Charging Challenge Partner: Township High School District...

    Broader source: Energy.gov (indexed) [DOE]

    School District 214 Workplace charging helps Township High School District 214's sustainability program by reducing its employees' carbon footprint in the community. The District...

  11. Central Vein Dilatation Prior to Concomitant Port Implantation

    SciTech Connect (OSTI)

    Krombach, Gabriele A., E-mail: krombach@rad.rwth-aachen.de; Plumhans, Cedric; Goerg, Fabian; Guenther, Rolf W. [University of Technology (RWTH) Aachen, Department of Diagnostic Radiology, University Hospital (Germany)

    2010-04-15T23:59:59.000Z

    Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker and occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.

  12. Hydrogen fuel cells could power ships at port

    SciTech Connect (OSTI)

    Pratt, Joe

    2013-06-27T23:59:59.000Z

    Sandia National Laboratories researcher Joe Pratt conducted a study on the use of hydrogen fuel cells to power docked ships at major ports. He found the potential environmental and cost benefits to be substantial. Here, he discusses the study and explains how hydrogen fuel cells can provide efficient, pollution-free energy to ships at port.

  13. Modeling Laser Treatment of Port Wine Stains With a

    E-Print Network [OSTI]

    Barton, Jennifer K.

    Modeling Laser Treatment of Port Wine Stains With a Computer-Reconstructed Biopsy T. Joshua Pfefer, The Netherlands Background and Objective: The efficacy of laser treatment of port wine stains (PWS) has been shown- length of 585 nm. Results: Energy deposition rate in the blood vessels was primar- ily a function

  14. Hydrogen fuel cells could power ships at port

    ScienceCinema (OSTI)

    Pratt, Joe

    2013-11-22T23:59:59.000Z

    Sandia National Laboratories researcher Joe Pratt conducted a study on the use of hydrogen fuel cells to power docked ships at major ports. He found the potential environmental and cost benefits to be substantial. Here, he discusses the study and explains how hydrogen fuel cells can provide efficient, pollution-free energy to ships at port.

  15. The state-of-the-art port of entry workshop

    SciTech Connect (OSTI)

    Godfrey, B.

    1995-05-01T23:59:59.000Z

    The increased demand for freight movements through international ports of entry and the signing of the North American Free Trade Agreement (NAFTA) have increased freight traffic at border ports of entry. The State-of-the-Art Port of Entry Workshop initiated a dialogue among technologists and stakeholders to explore the potential uses of technology at border crossings and to set development priorities. International ports of entry are both information and labor intensive, and there are many promising technologies that could be used to provide timely information and optimize inspection resources. Participants universally held that integration of technologies and operations is critical to improving port services. A series of Next Steps was developed to address stakeholder issues and national priorities, such as the National Transportation Policy and National Drug Policy. This report documents the views of the various stakeholders and technologists present at the workshop and outlines future directions of study.

  16. Port of Galveston Solar Energy Project

    SciTech Connect (OSTI)

    Falcioni, Diane [Project Director, Port of Galveston; Cuclis, Alex [Project Manager, Houston Advanced Research Center; Freundlich, Alex [Principal Investigator, University of Houston

    2014-03-31T23:59:59.000Z

    This study on the performance characteristics of existing solar technologies in a maritime environment was funded by an award given to The Port of Galveston (POG) from the U.S. Department of Energy (DOE). The study includes research performed by The Center for Advanced Materials at the University of Houston (UH). The UH researchers examined how solar cell efficiencies and life spans can be improved by examining the performance of a variety of antireflective (AR) coatings mounted on the top of one of the POG’s Cruise Terminals. Supplemental supporting research was performed at the UH laboratories. An educational Kiosk was constructed with a 55” display screen providing information about solar energy, the research work UH performed at POG and real time data from the solar panels located on the roof of the Cruise Terminal. The Houston Advanced Research Center (HARC) managed the project.

  17. Modern hot water district heating

    SciTech Connect (OSTI)

    Karnitz, M.A.; Barnes, M.H.; Kadrmas, C.; Nyman, H.O.

    1984-06-01T23:59:59.000Z

    The history of district heating in Europe is drastically different from that in the United States. The development of district heating in northern and eastern Europe started in the early 1950s. Hot water rather than steam was used as the transport medium and the systems have proven to be more economical. Recently, the northern European concept has been introduced into two US cities - St. Paul and Willmar, Minnesota. The hot water project in St. Paul started construction and operation in the summer and fall of 1983, respectively. The entire first phase of the St. Paul project will take two summers to construct and will connect approximately 80 buildings for a total of 150 MW(t). The system spans the entire St. Paul business district and includes privately owned offices and retail buildings, city and county government buildings, hospitals, the state Capitol complex, and several industrial customers. The City of Willmar, Minnesota, replaced an old steam system with a modern hot water system in the summer of 1982. The first phase of the hot water system was constructed in the central business district. The system serves a peak thermal load of about 10 MW(t) and includes about 12,000 ft of network. The Willmar system completed the second stage of development in the fall of 1983. These two new systems demonstrate the benefits of the low-temperature hot water district heating technology. The systems are economical to build, have high reliability, and have low maintenance and operating cost.

  18. Different tiers of government in port governance: some general remarks on the institutional geography of ports in Europe and Canada

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    , monitoring, management and public finance in order to understand the diversity of the public sector presence by the public sector to joint management by the maritime and port industry and various levels of the public and Safety Reserarch, France ABSTRACT For the last thirty years, port governance has been marked by a new

  19. Microsoft Word - Port Townsend Amendment DRAFT 5.2.12.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    an agreement to provide service to Port Townsend's Old Corrugated Container (OCC) recycle plant. The Parties also recognize that Port Townsend is working with Jefferson County...

  20. Evaluating Water Transfers in Irrigation Districts

    E-Print Network [OSTI]

    Ghimire, Narishwar

    2013-04-11T23:59:59.000Z

    The participation of irrigation districts (IDs) in surface water transfers from agriculture-to-municipal uses is studied by examining IDs’ economic and political behavior, comparing their performance with non-districts (non-IDs), and analyzing...

  1. University of the District of Columbia District of Columbia Drinking Water Blind Taste

    E-Print Network [OSTI]

    District of Columbia, University of the

    University of the District of Columbia District of Columbia Drinking Water Blind Taste Testing for Nutrition, Diet and Health Cooperative Extension Service University of the District of Columbia Dawanna University of the District of Columbia Date: May 2005 Prepared for the DC Water Resources Research Institute

  2. UNITED STATES DISTRICT COURT FOR THE DISTRICT OF COLUMBIA

    E-Print Network [OSTI]

    ___________________________________ ) THE HUMANE SOCIETY OF THE ) UNITED STATES, et al., ) ) Plaintiffs, ) ) v. ) Civil Action No. 05-1392 (ESH amendments be vacated; it is Case 1:05-cv-01392-ESH Document 29 Filed 05/26/2006 Page 1 of 2 #12;FURTHER/ ELLEN SEGAL HUVELLE United States District Judge Date: May 26, 2006 Case 1:05-cv-01392-ESH Document 29

  3. Vacant District Chair Positions (as of 1/28/2014)

    E-Print Network [OSTI]

    Cohen, Ronald C.

    , Lassen, Plumas Counties District 15 ­ Yuba & Sutter Counties District 16 ­ Tri-County Area (includes Red: NORTHERN CALIFORNIA District 10/11 ­ Siskiyou County, Humboldt & Eureka Counties District 13 ­ Modoc Bluff in Tehama County) REGION 2: SACRAMENTO & NORTH SIERRAS District 21 ­ El Dorado County District 23

  4. Pewter and pewterers from Port Royal, Jamaica: flatware before 1692

    E-Print Network [OSTI]

    Gotelipe-Miller, Shirley

    1990-01-01T23:59:59.000Z

    Figure 2: The INA/TAMU Archaeological Excavations at Port Royal Figure 3: Detail of ar i e a la Mod by William Hogarth Figure 4: Der Kandelgiesser (The Pewterer) by P. Abraham Figure 5: Scrap Pewter Recovered from INA/TAMU Excavations Figure 6: Array... Land Holdings in Port Royal Table 3: Childermas Family Tree Table fn Benning Land Holdings in Port Royal Table 5: Benning Family Tree Table 6: Benning Family Timeline Table 7: Comparison of Probate Inventories Table 8: Comparison of Prices derived...

  5. Pewter and pewterers from Port Royal, Jamaica: flatware before 1692 

    E-Print Network [OSTI]

    Gotelipe-Miller, Shirley

    1990-01-01T23:59:59.000Z

    Figure 2: The INA/TAMU Archaeological Excavations at Port Royal Figure 3: Detail of ar i e a la Mod by William Hogarth Figure 4: Der Kandelgiesser (The Pewterer) by P. Abraham Figure 5: Scrap Pewter Recovered from INA/TAMU Excavations Figure 6: Array... Land Holdings in Port Royal Table 3: Childermas Family Tree Table fn Benning Land Holdings in Port Royal Table 5: Benning Family Tree Table 6: Benning Family Timeline Table 7: Comparison of Probate Inventories Table 8: Comparison of Prices derived...

  6. Glove port retrofit assembly and method of replacing components

    DOE Patents [OSTI]

    Giesen, Isaac M; Cournoyer, Michael E; Rael, David G

    2014-11-18T23:59:59.000Z

    What is disclosed is a system for retrofitting a sealed enclosure for performing work therein having an outer enclosure assembly configured to be clamped to the outer annular face of a port ring and form a sealed engagement with the outer annular surface of the port ring, a change assembly having an inner ring and an access element wherein the inner ring has a first annular cylinder body that is sized to be slidably received by the port ring and the access element is configured to be sealably and slidably positioned within the first annular cylinder body of the inner ring.

  7. Code constructions and code families for nonbinary quantum stabilizer code

    E-Print Network [OSTI]

    Ketkar, Avanti Ulhas

    2005-11-01T23:59:59.000Z

    Stabilizer codes form a special class of quantum error correcting codes. Nonbinary quantum stabilizer codes are studied in this thesis. A lot of work on binary quantum stabilizer codes has been done. Nonbinary stabilizer codes have received much...

  8. Groundwater and geothermal: urban district heating applications

    SciTech Connect (OSTI)

    Mounts, R.; Frazier, A.; Wood, E.; Pyles, O.

    1982-01-01T23:59:59.000Z

    This report describes how several cities use groundwater and geothermal energy in district heating systems. It begins with groundwater, introducing the basic technology and techniques of development, and describing two case studies of cities with groundwater-based district heating systems. The second half of the report consists of three case studies of cities with district heating systems using higher temperature geothermal resources.

  9. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT_CODE","PORT_CITY

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells,1Stocks Nov-14 Dec-14Table 4.April 25, 20137a. SpacePrice

  10. Holographic codes

    E-Print Network [OSTI]

    Latorre, Jose I

    2015-01-01T23:59:59.000Z

    There exists a remarkable four-qutrit state that carries absolute maximal entanglement in all its partitions. Employing this state, we construct a tensor network that delivers a holographic many body state, the H-code, where the physical properties of the boundary determine those of the bulk. This H-code is made of an even superposition of states whose relative Hamming distances are exponentially large with the size of the boundary. This property makes H-codes natural states for a quantum memory. H-codes exist on tori of definite sizes and get classified in three different sectors characterized by the sum of their qutrits on cycles wrapped through the boundaries of the system. We construct a parent Hamiltonian for the H-code which is highly non local and finally we compute the topological entanglement entropy of the H-code.

  11. Holographic codes

    E-Print Network [OSTI]

    Jose I. Latorre; German Sierra

    2015-02-23T23:59:59.000Z

    There exists a remarkable four-qutrit state that carries absolute maximal entanglement in all its partitions. Employing this state, we construct a tensor network that delivers a holographic many body state, the H-code, where the physical properties of the boundary determine those of the bulk. This H-code is made of an even superposition of states whose relative Hamming distances are exponentially large with the size of the boundary. This property makes H-codes natural states for a quantum memory. H-codes exist on tori of definite sizes and get classified in three different sectors characterized by the sum of their qutrits on cycles wrapped through the boundaries of the system. We construct a parent Hamiltonian for the H-code which is highly non local and finally we compute the topological entanglement entropy of the H-code.

  12. Self-regulating fuel staging port for turbine combustor

    DOE Patents [OSTI]

    Van Nieuwenhuizen, William F.; Fox, Timothy A.; Williams, Steven

    2014-07-08T23:59:59.000Z

    A port (60) for axially staging fuel and air into a combustion gas flow path 28 of a turbine combustor (10A). A port enclosure (63) forms an air path through a combustor wall (30). Fuel injectors (64) in the enclosure provide convergent fuel streams (72) that oppose each other, thus converting velocity pressure to static pressure. This forms a flow stagnation zone (74) that acts as a valve on airflow (40, 41) through the port, in which the air outflow (41) is inversely proportion to the fuel flow (25). The fuel flow rate is controlled (65) in proportion to engine load. At high loads, more fuel and less air flow through the port, making more air available to the premixing assemblies (36).

  13. ,"Port of Morgan, MT Natural Gas Pipeline Imports From Canada...

    U.S. Energy Information Administration (EIA) Indexed Site

    Imports From Canada (MMcf)" ,"Click worksheet name or tab at bottom for data" ,"Worksheet Name","Description"," Of Series","Frequency","Latest Data for" ,"Data 1","Port of Morgan,...

  14. Analysis of the hollowware pewter from Port Royal, Jamaica

    E-Print Network [OSTI]

    Winslow, Debra Lynn

    2000-01-01T23:59:59.000Z

    Over the past forty years an enormous collection of pewter artifacts has been recovered from the various archaeological excavations at Port Royal, Jamaica, both on land and underwater (Link 1960; Marx 1971; Priddy 1975; Hamilton 1984, 1985, 1987...

  15. Port Angeles Public Works and Utilities- Solar Energy Loan Program

    Broader source: Energy.gov [DOE]

    The City of Port Angeles Public Works and Utilities offers a low-interest loan to its residential and commercial customers for certain renewable energy projects. The loan is available for...

  16. Natural thorium isotopes in marine sediment core off Labuan port

    SciTech Connect (OSTI)

    Hafidz, B. Y.; Asnor, A. S.; Terence, R. C.; Mohamed, C. A. R. [School of Environmental and Natural Resource Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia 43600, Bangi, Selangor (Malaysia)

    2014-02-12T23:59:59.000Z

    Sediment core was collected from Labuan port and analyzed to determine the radioactivity of thorium (Th) isotopes. The objectives of this study are to determine the possible sources of Th isotopes at Labuan port and estimates the sedimentation rate based on {sup 228}Th/{sup 232}Th model. The results suggest the {sup 230}Th and {sup 232}Th might be originated from terrestrial sedimentary rock while {sup 228}Th originated by authigenic origin. High ratio value of {sup 230}Th/{sup 232}Th detected at the top surface sediment indicates the increasing of {sup 230}Th at the recent years which might be contributed from the anthropogenic sources. The sedimentation rate of core sediment from Labuan Port was successfully estimated by using {sup 228}Th/{sup 232}Th model. The result show high sedimentation rate with 4.67 cm/year indicates rapid deposition occurred at this study area due to the high physical activity at the Labuan port. By assume the constant sedimentation rate at this area; we estimated the age of 142 cm core sediment obtained from Labuan port is 32 years started from 1981 to 2012. This chronology will be used in forthcoming research to investigate the historical profile of anthropogenic activities affecting the Labuan port.

  17. High Performance “Reach” Codes

    E-Print Network [OSTI]

    Edelson, J.

    2011-01-01T23:59:59.000Z

    Jim Edelson New Buildings Institute A Growing Role for Codes and Stretch Codes in Utility Programs Clean Air Through Energy Efficiency November 9, 2011 ESL-KT-11-11-39 CATEE 2011, Dallas, Texas, Nov. 7 ? 9, 2011 New Buildings Institute ESL..., Nov. 7 ? 9, 2011 ?31? Flavors of Codes ? Building Codes Construction Codes Energy Codes Stretch or Reach Energy Codes Above-code programs Green or Sustainability Codes Model Codes ?Existing Building? Codes Outcome-Based Codes ESL-KT-11...

  18. CURRICULUM CODE: 611 & 613 MINOR CODE 061 DEGREE CODE: 31

    E-Print Network [OSTI]

    Qiu, Weigang

    CURRICULUM CODE: 611 & 613 MINOR CODE 061 DEGREE CODE: 31 DAAF 12/09 Hunter College of the City Stamp THIS AUDIT IS NOT OFFICIAL UNTIL APPROVED BY THE OFFICE OF THE REGISTRAR DEGREE AUDIT UNIT Student Specialization Section #12;CURRICULUM CODE: 611 & 613 MINOR CODE 061 DEGREE CODE: 31 DAAF 12/09 *****A SEPARATE

  19. CURRICULUM CODE_611 & 613 MINOR CODE 062 DEGREE CODE _31_

    E-Print Network [OSTI]

    Qiu, Weigang

    CURRICULUM CODE_611 & 613 MINOR CODE 062 DEGREE CODE _31_ 1/24/2006 Hunter College of the City-mail address Department Stamp THIS AUDIT IS NOT OFFICIAL UNTIL APPROVED BY THE OFFICE OF THE REGISTRAR, DEGREE Section Only For January 2010 Graduate #12;CURRICULUM CODE_611 & 613 MINOR CODE 062 DEGREE CODE _31_ 1

  20. Groundbreaking High-Performance Building Districts

    E-Print Network [OSTI]

    Jordan, J.

    2014-01-01T23:59:59.000Z

    organizations and governments Business stakeholders 2030 Districts are business models for urban sustainability through collaboration, leveraged financing, and shared resources. ESL-KT-14-11-28 CATEE 2014: Clean Air Through Efficiency Conference, Dallas.... ? Understand the basics functions of a 2030 District. ? Recognize that the 2030 District process will produce a healthier and more productive building. ? Be able to apply the available resources. ? Be able to utilize the resources to produce more efficient...

  1. White Bear Lake Conservation District (Minnesota)

    Broader source: Energy.gov [DOE]

    This statute establishes the White Bear Lake Conservation District, which has the authority to set water and land use regulations for the area around White Bear Lake.

  2. Regional Districts, Commissions, and Authorities (South Carolina)

    Broader source: Energy.gov [DOE]

    This legislation establishes a number of regional districts, commissions, and authorities with the power to implement regulations and development plans for protected park and recreational areas.

  3. Berkeley County School District Rodney Thompson

    E-Print Network [OSTI]

    Kasman, Alex

    Berkeley County School District Rodney Thompson Chief Administrative Officer TO: Institutions of Higher Learning FROM: Rodney Thompson, Chief Administrative Officer Through: Dr. Anthony Parker

  4. Lassen Municipal Utility District- PV Rebate Program

    Broader source: Energy.gov [DOE]

    Lassen Municipal Utility District (LMUD) is providing incentives for its customers to purchase solar electric photovoltaic (PV) systems. Rebate levels will decrease annually over the life of the...

  5. District Heating with Renewable Energy Webinar

    Broader source: Energy.gov [DOE]

    This no cost Community Renewable Energy Success Stories webinar on "District Heating with Renewable Energy" presented by the Energy Department will feature two presentations. The first will discuss...

  6. Empire District Electric- Residential Energy Efficiency Rebate

    Broader source: Energy.gov [DOE]

    The Empire District Electric Company offers rebates for customers who construct highly efficient homes and purchase efficient central air conditioners. Eligible customers include residential...

  7. Community Renewable Energy Success Stories Webinar: District...

    Broader source: Energy.gov (indexed) [DOE]

    District Heating with Renewable Energy," originally presented on November 20, 2012. Operator: The broadcast is now starting. All attendees are in listen-only mode. Sarah Busche:...

  8. Business Energy Rebate Program (District of Columbia)

    Broader source: Energy.gov [DOE]

    The District of Columbia's Sustainable Energy Utility (SEU) administers the Business Energy Rebate Program. Rebates are available to businesses and institutions for the installation of energy...

  9. assist district health: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... clInIcal famIly meDIcIne anD DIstRIct health caRe systems1District health services research: 2011 District health services...

  10. akonolinga health district: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ... clInIcal famIly meDIcIne anD DIstRIct health caRe systems1District health services research: 2011 District health services...

  11. Speech coding

    SciTech Connect (OSTI)

    Ravishankar, C., Hughes Network Systems, Germantown, MD

    1998-05-08T23:59:59.000Z

    Speech is the predominant means of communication between human beings and since the invention of the telephone by Alexander Graham Bell in 1876, speech services have remained to be the core service in almost all telecommunication systems. Original analog methods of telephony had the disadvantage of speech signal getting corrupted by noise, cross-talk and distortion Long haul transmissions which use repeaters to compensate for the loss in signal strength on transmission links also increase the associated noise and distortion. On the other hand digital transmission is relatively immune to noise, cross-talk and distortion primarily because of the capability to faithfully regenerate digital signal at each repeater purely based on a binary decision. Hence end-to-end performance of the digital link essentially becomes independent of the length and operating frequency bands of the link Hence from a transmission point of view digital transmission has been the preferred approach due to its higher immunity to noise. The need to carry digital speech became extremely important from a service provision point of view as well. Modem requirements have introduced the need for robust, flexible and secure services that can carry a multitude of signal types (such as voice, data and video) without a fundamental change in infrastructure. Such a requirement could not have been easily met without the advent of digital transmission systems, thereby requiring speech to be coded digitally. The term Speech Coding is often referred to techniques that represent or code speech signals either directly as a waveform or as a set of parameters by analyzing the speech signal. In either case, the codes are transmitted to the distant end where speech is reconstructed or synthesized using the received set of codes. A more generic term that is applicable to these techniques that is often interchangeably used with speech coding is the term voice coding. This term is more generic in the sense that the coding techniques are equally applicable to any voice signal whether or not it carries any intelligible information, as the term speech implies. Other terms that are commonly used are speech compression and voice compression since the fundamental idea behind speech coding is to reduce (compress) the transmission rate (or equivalently the bandwidth) And/or reduce storage requirements In this document the terms speech and voice shall be used interchangeably.

  12. Special Improvement Districts for Redevelopment of Blighted Areas (Indiana)

    Broader source: Energy.gov [DOE]

    Local redevelopment commissions may designate special improvement districts to aid local public improvements and provide special benefits to district property owners.

  13. New Mexico State University District Heating Low Temperature...

    Open Energy Info (EERE)

    New Mexico State University District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name New Mexico State University District Heating Low Temperature...

  14. State-Ocean City Beach Erosion Control District (Maryland)

    Broader source: Energy.gov [DOE]

    A Beach Erosion Control District constitutes part of the Ocean City shoreline. Land clearing, construction activity, or the construction or placement of permanent structures within the district is...

  15. Oregon Institute of Technology District Heating Low Temperature...

    Open Energy Info (EERE)

    District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Oregon Institute of Technology District Heating Low Temperature Geothermal Facility Facility...

  16. Fort Boise Veteran's Hospital District Heating Low Temperature...

    Open Energy Info (EERE)

    Veteran's Hospital District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Fort Boise Veteran's Hospital District Heating Low Temperature Geothermal...

  17. Modesto Irrigation District- Commercial Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Modesto Irrigation District’s Commercial Power Saver Rebate Program offers incentives to commercial, industrial, and agricultural customers for the purchase and installation of qualifying energy...

  18. Modesto Irrigation District- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Modesto Irrigation District’s Home Rebate Program offers residential customers cash rebates for the purchase and installation of qualifying energy efficient products installed in existing homes....

  19. Sustainable Energy Utility- Residential Energy Efficiency Program (District of Columbia)

    Broader source: Energy.gov [DOE]

    The District of Columbia Sustainable Energy Utility currently offers the Residential Energy Efficiency Program. The program provides financial incentives to District residents who install energy-...

  20. Okaloosa Gas District Smart Grid RFI: Addressing Policy and Logistical...

    Energy Savers [EERE]

    Okaloosa Gas District Smart Grid RFI: Addressing Policy and Logistical Challenges to Smart Grid Implementation Okaloosa Gas District Smart Grid RFI: Addressing Policy and...

  1. amansie west district: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from prosecution, school districts run the substantial risk of extremely negative media publicity when... Smith, Richard Kimball 2005-08-29 18 Rangitikei District Visitor...

  2. EIS-0511: Aguirre Offshore GasPort Project, Puerto Rico

    Broader source: Energy.gov [DOE]

    FERC prepared an EIS with 10 cooperating agencies, including DOE, for the proposed Aguirre Offshore GasPort Project. The proposal would include construction and operation of a marine LNG-receiving facility about 1 mile outside of Jobos Bay, near the towns of Salinas and Guayama, Puerto Rico, and a 4-mile subsea pipeline connecting to the Aguirre Plant in Salinas.

  3. Four-port gas separation membrane module assembly

    DOE Patents [OSTI]

    Wynn, Nicholas P. (Redwood City, CA); Fulton, Donald A. (Fairfield, CA); Lokhandwala, Kaaeid A. (Fremont, CA); Kaschemekat, Jurgen (Campbell, CA)

    2010-07-20T23:59:59.000Z

    A gas-separation membrane assembly, and a gas-separation process using the assembly. The assembly incorporates multiple gas-separation membranes in an array within a single vessel or housing, and is equipped with two permeate ports, enabling permeate gas to be withdrawn from both ends of the membrane module permeate pipes.

  4. Finally Underway: Implementation of the Port Hope Area Initiative - 13151

    SciTech Connect (OSTI)

    Fahey, Christine A. [Atomic Energy of Canada Ltd, Port Hope, ON (Canada)] [Atomic Energy of Canada Ltd, Port Hope, ON (Canada); Palmeter, Tim [Public Works and Government Services Canada, Port Hope, ON (Canada)] [Public Works and Government Services Canada, Port Hope, ON (Canada); Blanchette, Marcia [Natural Resources Canada, Ottawa, ON (Canada)] [Natural Resources Canada, Ottawa, ON (Canada)

    2013-07-01T23:59:59.000Z

    Two distinct yet closely related waste remediation projects are finally underway in Canada under the Port Hope Area Initiative (PHAI) which aims to clean up 1.7 million cubic metres (m{sup 3}) of low-level radioactive waste (LLRW) arising from 60 years of uranium and radium operations. Under the PHAI, the Port Hope Project and the smaller Port Granby Project will result in the consolidation of the LLRW within two highly engineered, above-ground mounds, to be constructed within the municipalities of Port Hope and Clarington. These projects will fulfill the federal government commitment to the safe, long-term management of the LLRW, as set out in the legal agreement signed by the government and the host municipalities in 2001. The federal authorization to commence PHAI Remediation and Construction Phase 2 was received in late 2011 and several enabling infrastructure construction and radiological survey contracts were awarded in 2012. The contracts to remediate the waste sites and construct the new engineered mounds will be tendered in 2013. At the end of Phase 2, environmental risks will be substantially mitigated, land development restrictions lifted, and an honourable legacy left for future generations. (authors)

  5. Fuel Consumption and NOx Trade-offs on a Port-Fuel-Injected SI...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Consumption and NOx Trade-offs on a Port-Fuel-Injected SI Gasoline Engine Equipped with a Lean-NOx Trap Fuel Consumption and NOx Trade-offs on a Port-Fuel-Injected SI Gasoline...

  6. V-078: WordPress Bugs Permit Cross-Site Scripting and Port Scanning...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    8: WordPress Bugs Permit Cross-Site Scripting and Port Scanning Attacks V-078: WordPress Bugs Permit Cross-Site Scripting and Port Scanning Attacks January 28, 2013 - 12:32am...

  7. Port Arthur LNG, (LLC)- FE Dkt.No. 15-96-LNG

    Broader source: Energy.gov [DOE]

    The Office of Fossil Energy gives notice of receipt of an Application filed March 20, 2015, by Port Arthur LNG, (LLC) (Port Arthur LNG), seeking a long-term multi-contract authorization to export...

  8. Microsoft Word - PortTownsend IP Contract 10_08_09.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    09 DRAFT 09PB-XXXXX12106, Port Townsend 2 RECITALS BPA will sell and Port Townsend will purchase an amount of Industrial Firm Power under this Agreement. BPA has functionally...

  9. V-021: Cisco IronPort Web / Email Security Appliance Sophos Anti...

    Broader source: Energy.gov (indexed) [DOE]

    1: Cisco IronPort Web Email Security Appliance Sophos Anti-Virus Multiple Vulnerabilities V-021: Cisco IronPort Web Email Security Appliance Sophos Anti-Virus Multiple...

  10. Seismic Risk Assessment of Port Facilities Ung Jin Na, Samit Ray Chaudhuri

    E-Print Network [OSTI]

    Shinozuka, Masanobu

    Seismic Risk Assessment of Port Facilities Ung Jin Na, Samit Ray Chaudhuri Faculty Advisor : Prof Estimation Methodology Applications (in progress) Port of Long Beach · Seismic Risk Assessment, Decision & Vertical movement, Settlement of Apron Seismic Vulnerability - quay Wall

  11. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    SSOR-TX","TX","TEXAS",3 "applicationvnd.ms-excel","ASTRA OIL CO LLC ",2,138,"All Other Motor Gas Blending Components",1001,"NEW YORK, NY","NEW YORK",1,940,"VENEZUELA",51,0,0,"KIND...

  12. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    MN","MINNESOTA",2,260,"CANADA",11,0,0,,,,, 37652,"AMERADA HESS CORP ",1,152,"MOTOR GAS, OTHER FINISHED",1601,"CHARLESTON, SC","SOUTH CAROLINA",1,150,"ARGENTINA",234,0,0,...

  13. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    HESS CORP ","SEWAREN","NJ","NEW JERSEY",1 38383,"AMERADA HESS CORP ",105,138,"MOTOR GAS BLENDING COMPONENTS, ALL OTHER",1004,"PERTH AMBOY, NJ","NEW JERSEY",1,670,"NIGERIA...

  14. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    NA",4,260,"CANADA",19,0,0,,,,,," " "applicationvnd.ms-excel","ANDERES OIL INC ",1,130,"Motor Gas, Conventional, Other",3102,"KETCHIKAN, AK","ALASKA",5,260,"CANADA",2,0,0,,,,,," "...

  15. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    PENNSYLVANIA",1,078,"VIRGIN ISLANDS, U.S.",51,0,0,,,,, 34365,"AMERADA HESS CORP",1,152,"MOTOR GAS, OTHER FINISHED",1801,"TAMPA, FL","FLORIDA",1,078,"VIRGIN ISLANDS,...

  16. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    HURON, MI","MICHIGAN",2,260,"CANADA",10,0,0,,,,,," " 41305,"ANDERES OIL INC ",1,130,"Motor Gas, Conventional, Other",3102,"KETCHIKAN, AK","ALASKA",5,260,"CANADA",8,0,0,,,,,," "...

  17. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    FL, NY","NEW YORK",1,260,"CANADA",2,0,0,,,,, 38748,"AMERICAN AGIP CO INC ",3,130,"MOTOR GAS, CONVENTIONAL, OTHER",1003,"NEWARK, NJ","NEW JERSEY",1,480,"ITALY",65,0,0,,,,,...

  18. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    FL","FLORIDA",1,940,"VENEZUELA",322,2.6,0,,,,, 35826,"AECTRA REFG & MKTG",2,152,"MOTOR GAS, OTHER FINISHED",1803,"JACKSONVILLE, FL","FLORIDA",1,940,"VENEZUELA",220,0,0,,,,,...

  19. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    MI","MICHIGAN",2,260,"CANADA",34,0,0,,,,, 34000,"AMERADA HESS CORP",1,152,"MOTOR GAS, OTHER FINISHED",5203,"PT EVERGLADE, FL","FLORIDA",1,078,"VIRGIN ISLANDS,...

  20. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    MN","MINNESOTA",2,260,"CANADA",3,0,0,,,,, 39478,"ALPAC MARKETING SERV ",1,130,"MOTOR GAS, CONVENTIONAL, OTHER",5301,"HOUSTON, TX","TEXAS",3,190,"BELGIUM",32,0,0,,,,,...

  1. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    Other Motor Gas Blending Components",1003,"NEWARK, NJ","NEW JERSEY",1,685,"NORWAY",41,0,0,"KINDER MORGAN ",408,"CARTERET","NJ","NEW JERSEY",1 "application...

  2. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    Other Motor Gas Blending Components",1003,"NEWARK, NJ","NEW JERSEY",1,685,"NORWAY",50,0,0,"IMTT ",438,"BAYONNE","NJ","NEW JERSEY",1 "applicationvnd.ms-excel","ATLANTIC...

  3. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    BANK PLC ",2,025,"Crude Oil",3201,"HONOLUPEARL, HA","HAWAII",5,150,"ARGENTINA",995,0.19,24.2,"HAWAII INDEPENDENT ENERGY ",363,"KAPOLEI","HI","HAWAII",5...

  4. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    5,510,"Residual Fuel, Over 1.00% Sulfur",1003,"NEWARK, NJ","NEW JERSEY",1,220,"BRAZIL",11,3.41,0,,,,,," " "applicationvnd.ms-excel","AEGEAN BUNKERING USA LLC ",11,510,"Residual...

  5. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    AEGEAN BUNKERING USA LLC ",1,510,"Residual Fuel, Over 1.00% Sulfur",1601,"CHARLESTON, SC","SOUTH CAROLINA",1,260,"CANADA",38,4.11,0,,,,,," " "applicationvnd.ms-excel","AEGEAN...

  6. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    4,510,"Residual Fuel, Over 1.00% Sulfur",1003,"NEWARK, NJ","NEW JERSEY",1,260,"CANADA",100,2.19,0,,,,,," " "applicationvnd.ms-excel","AEGEAN BUNKERING USA LLC ",3,510,"Residual...

  7. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    1,510,"Residual Fuel, Over 1.00% Sulfur",1401,"NORFOLK, VA","VIRGINIA",1,220,"BRAZIL",15,3.45,0,,,,,," " "applicationvnd.ms-excel","AEGEAN BUNKERING USA LLC ",2,510,"Residual...

  8. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    AEGEAN BUNKERING USA LLC ",1,510,"Residual Fuel, Over 1.00% Sulfur",1003,"NEWARK, NJ","NEW JERSEY",1,260,"CANADA",70,5.13,0,,,,,," " "applicationvnd.ms-excel","AEGEAN BUNKERING...

  9. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    " "applicationvnd.ms-excel","AEGEAN BUNKERING USA LLC ",2,510,"Residual Fuel, Over 1.00% Sulfur",1003,"NEWARK, NJ","NEW JERSEY",1,260,"CANADA",93,2.63,0,,,,,," "...

  10. RPT_PERIOD","R_S_NAME","LINE_NUM","PROD_CODE","PROD_NAME","PORT...

    U.S. Energy Information Administration (EIA) Indexed Site

    201,"SPRAGUE ENERGY CORP",1,461,"DIST, < 0.05% SUL (DOM.)",0131,"PORTSMOUTH, NH","NH",100,260,"CANADA",114,0,0 0201,"SPRAGUE ENERGY CORP",2,461,"DIST, < 0.05% SUL...

  11. Air Pollution Impacts of Shifting San Pedro Bay Ports Freight from Truck to Rail in Southern California

    E-Print Network [OSTI]

    You, Soyoung Iris; Lee, Gunwoo; Ritchie, Stephen G.; Saphores, Jean-Daniel; Sangkapichai, Mana; Ayala, Roberto

    2010-01-01T23:59:59.000Z

    Lower Reduced Port truck emissions (1) Additional LocomotiveNet Change = Reduced Port truck emissions – Added Locomotivetrucks. In particular, truck emission reduction strategies

  12. Optimizing Port of Entry Inspection Securing our ports and harbors is a major component of protecting our homeland. The

    E-Print Network [OSTI]

    , such as chemical or biological agents, or nuclear devices requires high vigilance. Even a small event at a major, document screening is the least expensive; physical methods, such as gamma ray detection, are more for intercepting illicit materials and weapons entering US ports. The algorithms we seek aim at finding inspection

  13. Decontamination of Dredged Material from The Port of New York and New Jersey

    E-Print Network [OSTI]

    Brookhaven National Laboratory

    Decontamination of Dredged Material from The Port of New York and New Jersey .K.W. Jones Brookhaven copyrightcoveringthispaper. #12;Decontamination of Dredged Material from The Port of New York and New Jersey K. W. Jones the dredging operations required for the efficient operation of the Port. Decontamination and beneficial reuse

  14. Towards Automatically Estimating Porting Effort Between Web Service APIs Hiranya Jayathilaka, Chandra Krintz, Rich Wolski

    E-Print Network [OSTI]

    Bigelow, Stephen

    Towards Automatically Estimating Porting Effort Between Web Service APIs Hiranya Jayathilaka for a programmer to port an application from one web API to another, i.e. "porting effort". Our approach defines approach using both randomly generated and real-world web APIs and show that our metric can correctly

  15. Building Energy Code

    Broader source: Energy.gov [DOE]

    The Bureau of Construction Codes is responsible for the administration of the State Construction Code Act (1972 PA 230), also known as the Uniform Construction Code.

  16. Analysis of solar radiation data for Port Harcourt, Nigeria

    SciTech Connect (OSTI)

    Kuye, A. (Univ. of Port Harcourt (Nigeria)); Jagtap, S.S. (International Inst. of Tropical Agriculture, Ibadan (Nigeria))

    1992-08-01T23:59:59.000Z

    The data on global irradiation incident on a horizontal surface in Port Harcourt during the 13-year period 1977-1989 are analyzed and shown to vary with the climatic changes of the year. The range of variation is found to be greatest in August. Based on the calculated average monthly clearness index values only five seasonal patterns are identified for Port Harcourt. The percentage of days with duration of sunshine less than 1.5 h is 28.3% while that greater than 9 h is 4.3%. The Angstrom type of regression model relating total global irradiation to sunshine duration has been found to be reasonably adequate only if long-term average monthly values are used.

  17. Applied Solutions Webinar: Insights Into District Energy

    Office of Energy Efficiency and Renewable Energy (EERE)

    Local governments and their communities that inhabit dense locations can take advantage of district heating and/or cooling systems as a way to increase energy efficiency and reliability while...

  18. Soil and Water Conservation Districts (South Carolina)

    Broader source: Energy.gov [DOE]

    Soil and Water Conservation Districts are local governmental subdivisions of the state of South Carolina, established to provide for land and water conservation and prevent erosion in the state....

  19. Garrison Diversion Conservancy District (North Dakota)

    Broader source: Energy.gov [DOE]

    The Garrison Conservancy District is a state agency established to provide for land irrigation, to establish and restore depleted lakes and stabilize stream flows, and to make waters available for...

  20. Major Source Permits (District of Columbia)

    Broader source: Energy.gov [DOE]

    The District reviews designs for new pollution sources and design modifications for existing sources. Permits are issued to allow sources to emit limited and specified amounts of pollution as...

  1. Merced Irrigation District- PV Buydown Program

    Broader source: Energy.gov [DOE]

    Merced Irrigation District (MID) offers its residential, commercial and non-profit customers a rebate for installing solar electric photovoltaic (PV) systems on their homes and offices. The rebate...

  2. Modesto Irrigation District- Photovoltaic Rebate Program

    Broader source: Energy.gov [DOE]

    Modesto Irrigation District offers a photovoltaic rebate program for all of their electric customers. The peak output capacity of a system must be 1 kW or greater to participate. Systems up to 30...

  3. Solidere : the battle for Beirut's Central District

    E-Print Network [OSTI]

    Mango, Tamam, 1981-

    2004-01-01T23:59:59.000Z

    The Beirut Central District was destroyed during the Lebanese Civil War which extended from 1975 to 1990. Unable to reconstruct the center itself, the Lebanese government turned to a private Real Estate Holding Company ...

  4. Western Lake Superior Sanitary District (Minnesota)

    Broader source: Energy.gov [DOE]

    A sanitary board is established to deal with long-term serious problems relating to water pollution and solid waste disposal in the area. The district can set regulations regarding garbage...

  5. Recreational Lake and Water Quality Districts (Iowa)

    Broader source: Energy.gov [DOE]

    Territory contiguous to a recreational lake may be incorporated into a recreational lake and water quality district if such action is conducive to the public health, comfort, convenience, water...

  6. Industrial Revenue Bond Program (District of Columbia)

    Broader source: Energy.gov [DOE]

    The District provides below market bond financing to lower the costs of borrowing for qualified capital construction and renovation projects. The program is available to non-profits, institutions,...

  7. Underground Storage Tank Management (District of Columbia)

    Broader source: Energy.gov [DOE]

    The  installation, upgrade and operation of any petroleum UST (>110 gallons) or hazardous substance UST System, including heating oil tanks over 1,100 gallons capacity in the District requires a...

  8. District of Columbia Recovery Act State Memo

    Broader source: Energy.gov [DOE]

    The American Recovery & Reinvestment Act (ARRA) is making a meaningful down payment on the nation’s energy and environmental future. The Recovery Act investments in the District of Columbia...

  9. Two-port microwave calibration at millikelvin temperatures

    SciTech Connect (OSTI)

    Ranzani, Leonardo; Spietz, Lafe; Aumentado, Jose [National Institute of Standards and Technology, Boulder, Colorado 80305 (United States); Popovic, Zoya [University of Colorado at Boulder, Boulder, Colorado 80309 (United States)

    2013-03-15T23:59:59.000Z

    In this work we introduce a system for 2-port microwave calibration at millikelvin temperatures operating at the coldest stage of a dilution refrigerator by use of an adapted thru-reflect-line algorithm. We show that this can be an effective tool for characterizing common 50 {Omega} microwave components with better than 0.1 dB accuracy at temperatures that are relevant to many current experiments in superconducting quantum information.

  10. Generalized concatenated quantum codes

    E-Print Network [OSTI]

    Grassl, Markus

    We discuss the concept of generalized concatenated quantum codes. This generalized concatenation method provides a systematical way for constructing good quantum codes, both stabilizer codes and nonadditive codes. Using ...

  11. Concatenated Conjugate Codes

    E-Print Network [OSTI]

    Mitsuru Hamada

    2006-10-31T23:59:59.000Z

    A conjugate code pair is defined as a pair of linear codes either of which contains the dual of the other. A conjugate code pair represents the essential structure of the corresponding Calderbank-Shor-Steane (CSS) quantum code. It is known that conjugate code pairs are applicable to (quantum) cryptography. We give a construction method for efficiently decodable conjugate code pairs.

  12. The Regulation of District Energy Systems Peter Ostergaard, Smart Planning for Communities

    E-Print Network [OSTI]

    Pedersen, Tom

    The Regulation of District Energy Systems Peter Ostergaard, Smart Planning for Communities ...................................................................................... 6 4. District Energy Systems ­ BCUC-Regulated.....................................................................11 5. District Energy Systems ­ Local Government Regulated

  13. CURRICULUM CODE 308 DEGREE CODE _40

    E-Print Network [OSTI]

    Qiu, Weigang

    CURRICULUM CODE 308 DEGREE CODE _40 Hunter College of the City University of New York - Office Print) E-mail address OES Stamp THIS AUDIT IS NOT OFFICIAL UNTIL APPROVED BY THE OFFICE OF THE REGISTRAR Specialization Section #12;CURRICULUM CODE_308_ DEGREE CODE _40__ Course Prefix & Number Course Title Credits

  14. Western US steam coal exports to the Pacific Basin: port and marine task group. [Data on 26 possible Western USA ports and terminal facilities

    SciTech Connect (OSTI)

    Not Available

    1981-11-01T23:59:59.000Z

    Volume 5 sets forth considerations and options in developing coal ports on the West Coast of the US. It includes information on the size, configuration, and ownership of the present and planned world bulk vessel fleet, as well as factors affecting the cost and efficiency of sealift transportation alternatives - including Panamax and VLCCs. The report also covers capacity and timing of development for receiving ports, synthesized from research and discussions with industry and government officials in Japan, South Korea, and the Republic of China. The physical and environmental aspects of announced plans to expand West Coast port capacity, capital and operating costs, and lead times for port expansion are also covered. The report includes marine charts and serial photographs of the 26 planned West Coast port sites.

  15. The Status of USITER Diagnostic Port Plug Neutronics Analysis Using Attila

    SciTech Connect (OSTI)

    Feder, Russell [1; Youssef, Mahamoud [2; Klabacha, Jonathan [1

    2013-11-01T23:59:59.000Z

    USITER is one of seven partner domestic agencies (DA) contributing components to the ITER project. Four diagnostic port plug packages (two equatorial ports and two upper ports) will be engineered and fabricated by Princeton Plasma Physics Lab (PPPL). Diagnostic port plugs as illustrated in Fig. 1 are large primarily stainless steel structures that serve several roles on ITER. The port plugs are the primary vacuum seal and tritium confinement barriers for the vessel. The port plugs also house several plasma diagnostic systems and other machine service equipment. Finally, each port plug must shield high energy neutrons and gamma photons from escaping and creating radiological problems in maintenance areas behind the port plugs. The optimization of the balance between adequate shielding and the need for high performance, high throughput diagnostics systems is the focus of this paper. Neutronics calculations are also needed for assessing nuclear heating and nuclear damage in the port plug and diagnostic components. Attila, the commercially available discrete-ordinates software package, is used for all diagnostic port plug neutronics analysis studies at PPPL.

  16. Soft-Tissue-Anchored Transcutaneous Port for Long-Term Percutaneous Transhepatic Biliary Drainage

    SciTech Connect (OSTI)

    Nyman, Rickard, E-mail: rickard.nyman@akademiska.se; Ekloef, Hampus; Eriksson, Lars-Gunnar [University Hospital, Department of Diagnostic Radiology (Sweden); Karlsson, Britt-Marie; Rasmussen, Ib [University Hospital, Department of Surgery (Sweden); Lundgren, Dan; Thomsen, Peter [Goeteborg University, Biomaterials/Cell Biology (Sweden)

    2005-01-15T23:59:59.000Z

    Purpose. A transcutaneous port (T-port) has been developed allowing easy exchange of a catheter, which was fixed inside the device, using the Seldinger technique. The objective of the study was to test the T-port in patients who had percutaneous transhepatic biliary drainage (PTBD). Methods. The T-port, made of titanium, was implanted using local anesthesia in 11 patients (mean age 65 years, range 52-85 years) with biliary duct obstruction (7 malignant and 4 benign strictures). The subcutaneous part of the T-port consisted of a flange with several perforations allowing ingrowth of connective tissue. The T-port allowed catheter sizes of 10 and 12 Fr. Results. All wounds healed uneventfully and were followed by a stable period without signs of pronounced inflammation or infection. It was easy to open the port and to exchange the drainage tube. The patient's quality of life was considerably improved even though several patients had problems with repeated bile leakage due to frequent recurrent obstructions of the tubes. The ports were implanted for a mean time of 9 months (range 2-21 months). Histologic examination in four cases showed that the port was well integrated into the soft tissue. Tilting of the T-port in two cases led to perforation of the skin by the subcutaneous part of the ports, which were removed after 7 and 8 months. Conclusion. The T-port served as an excellent external access to the biliary ducts. The drainage tubes were well fixed within the ports. The quality of life of the patients was considerably improved. Together with improved aesthetic appearance they found it easier to conduct normal daily activities and personal care. However, the problem of recurrent catheter obstruction remained unsolved.

  17. Homological stabilizer codes

    SciTech Connect (OSTI)

    Anderson, Jonas T., E-mail: jonastyleranderson@gmail.com

    2013-03-15T23:59:59.000Z

    In this paper we define homological stabilizer codes on qubits which encompass codes such as Kitaev's toric code and the topological color codes. These codes are defined solely by the graphs they reside on. This feature allows us to use properties of topological graph theory to determine the graphs which are suitable as homological stabilizer codes. We then show that all toric codes are equivalent to homological stabilizer codes on 4-valent graphs. We show that the topological color codes and toric codes correspond to two distinct classes of graphs. We define the notion of label set equivalencies and show that under a small set of constraints the only homological stabilizer codes without local logical operators are equivalent to Kitaev's toric code or to the topological color codes. - Highlights: Black-Right-Pointing-Pointer We show that Kitaev's toric codes are equivalent to homological stabilizer codes on 4-valent graphs. Black-Right-Pointing-Pointer We show that toric codes and color codes correspond to homological stabilizer codes on distinct graphs. Black-Right-Pointing-Pointer We find and classify all 2D homological stabilizer codes. Black-Right-Pointing-Pointer We find optimal codes among the homological stabilizer codes.

  18. Synergistic air port corrosion in kraft recovery boilers

    SciTech Connect (OSTI)

    Holcomb, Gordon R.

    2001-08-01T23:59:59.000Z

    Localized hot corrosion can occur on the cold-side of air-ports in Kraft recovery boilers. Depending on the basicity of the molten salt, either acidic or basic fluxing takes place, with a solubility minima at the transition between the two reactions. For stainless steel, if the basicity of the fused salt is between the iron and chromium oxide solubility minima, then a synergistic effect can occur that leads to rapid corrosion. The products of one reaction are the reactants of the other, which eliminates the need for rate-controlling diffusion. This effect can explain why stainless steel is attacked more readily than carbon steel.

  19. Port Moller Hot Springs Geothermal Area | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation,Pillar Group BV Jump to: navigation, searchPocatelloIII WindPort Moller Hot

  20. Port Salerno, Florida: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to: navigation,Pillar Group BV Jump to: navigation, searchPocatelloIII WindPort Moller

  1. Harwich Port, Massachusetts: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are8COaBulkTransmissionSitingProcess.pdfGetec AG| OpenInformationHartsville, New York: Energy ResourcesCenter,Port,

  2. RockPort Capital Partners (Massachusetts) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to:Ezfeedflag JumpID-f < RAPID‎ |Rippey Jump to: navigation,RockPort Capital Partners

  3. Dennis Port, Massachusetts: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOE Facility DatabaseMichigan: Energy ResourcesDenair,Dennis Port, Massachusetts:

  4. RockPort Capital Partners (California) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro Industries Pvt Ltd Jump to: navigation,MazeOhio:Ohio: Energy Jump to:RockPort Capital Partners

  5. Half-Product Codes

    E-Print Network [OSTI]

    Emmadi, Santosh Kumar

    2014-12-11T23:59:59.000Z

    A class of codes, half-product codes, derived from product codes, is characterized. These codes have the implementation advantages of product codes and possess a special structural property which leads them to have larger (at least 3/2 times more...

  6. Port Angeles Public Works and Utilities- Commercial and Industrial Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Port Angeles Public Works and Utilities provides incentives for business customers to increase the energy efficiency of eligible facilities. Rebates are offered for a variety of improvements...

  7. All-optical routing of single photons with multiple input and output ports by interferences

    E-Print Network [OSTI]

    Wei-Bin Yan; Bao Liu; Ling Zhou; Heng Fan

    2014-09-23T23:59:59.000Z

    We propose a waveguide-cavity coupled system to achieve the routing of photons by the phases of other photons. Our router has four input ports and four output ports. The transport of the coherent-state photons injected through any input port can be controlled by the phases of the coherent-state photons injected through other input ports. This control can be achieved when the mean numbers of the routed and control photons are small enough and require no additional control fields. Therefore, the all-optical routing of photons can be achieved at the single-photon level.

  8. Effect of Proposed Port User Fees on Export Grain Flow Patterns.

    E-Print Network [OSTI]

    Viscencio-Brambila, Hector; Fuller, Stephen W.

    1987-01-01T23:59:59.000Z

    and the resulting user fee is proj ected to redirect nearly 160 million bushels of corn and soybeans from this port area. This grain is redirected to Mississippi River ports which are projected to increase export volume by 248 million bushels. A portion..., and North Atlantic port areas. The Mississippi River port area is the most impor tant grain outlet in the nation, accounting for up to 40 percent of U.S. agriculture's grain exports. Depend ing on the user fee scenario analyzed, increases in export...

  9. Collective private urban renewal in New Bedford's historic district

    E-Print Network [OSTI]

    Bullard, John K. (John Kilburn)

    1974-01-01T23:59:59.000Z

    This thesis examines the waterfront historic district in New Bedford, Massachusetts. It is, hopefully, the beginning of a process of collective private renewal that may lead the revival of the district as a vital element ...

  10. Alaska Gateway School District Adopts Combined Heat and Power...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Alaska Gateway School District Adopts Combined Heat and Power Alaska Gateway School District Adopts Combined Heat and Power May 7, 2013 - 12:00am Addthis In Tok, Alaska, the...

  11. District Courts as Patent Laboratories Jeanne C. Fromer*

    E-Print Network [OSTI]

    Loudon, Catherine

    307 District Courts as Patent Laboratories Jeanne C. Fromer* Introduction .....................................................................................................................307 I. The Federal Circuit's Supervisory Role in Patent Law..........................................308 II. District Courts as the Federal Circuit's Patent Laboratories..............................311

  12. Cogeneration Personal Property Tax Credit (District of Columbia)

    Broader source: Energy.gov [DOE]

    The District of Columbia Council created a personal property tax exemption for solar energy systems and cogeneration systems within the District by enacting B19-0749 in December of 2012.

  13. List of codes Language abbreviation codes

    E-Print Network [OSTI]

    Portugal MT Malta GR Greece SE Sweden TR Turkey Country codes for the ERASMUS Institutional Identification codes A Austria IR L Ireland BG Bulgaria LV Latvia B Belgium IS Iceland CY Cyprus MT Malta D Germany L

  14. Generalized Concatenation for Quantum Codes

    E-Print Network [OSTI]

    Grassl, Markus

    We show how good quantum error-correcting codes can be constructed using generalized concatenation. The inner codes are quantum codes, the outer codes can be linear or nonlinear classical codes. Many new good codes are ...

  15. Energy Department Works with Sacramento Municipal Utility District...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    About Us Initiatives & Projects Energy Transition Initiative Energy Department Works with Sacramento Municipal Utility District on Renewable Electricity Generation and...

  16. Quantum convolutional stabilizer codes

    E-Print Network [OSTI]

    Chinthamani, Neelima

    2004-09-30T23:59:59.000Z

    Quantum error correction codes were introduced as a means to protect quantum information from decoherance and operational errors. Based on their approach to error control, error correcting codes can be divided into two different classes: block codes...

  17. Guam- Building Energy Code

    Broader source: Energy.gov [DOE]

    NOTE: In September 2012, The Guam Building Code Council adopted the draft [http://www.guamenergy.com/outreach-education/guam-tropical-energy-code/ Guam Tropical Energy Code]. It must be adopted by...

  18. Building Energy Code

    Broader source: Energy.gov [DOE]

    In 2009 S.B. 1182 created the Oklahoma Uniform Building Code Commission. The 11-member Commission was given the power to conduct rulemaking processes to adopt new building codes. The codes adopted...

  19. St. Paul -West Bank District Heating-to-Cooling Conversion Plan Check the date your building's cooling system is scheduled to be on.

    E-Print Network [OSTI]

    Webb, Peter

    's cooling system is scheduled to be on. Status Color Code: On In Progress Not started Building Name BuildingSt. Paul - West Bank District Heating-to-Cooling Conversion Plan Check the date your building # Date Central Cooling On Status Date Window A/C Units installed Status 19th ave ramp 217 N/A N/A N/A 21

  20. Health Sciences District Heating-to-Cooling Conversion Plan Check the date your building's cooling system is scheduled to be on.

    E-Print Network [OSTI]

    Webb, Peter

    system is scheduled to be on. Status Color Code: On In Progress Not started *** - Typically between May 1Health Sciences District Heating-to-Cooling Conversion Plan Check the date your building's cooling-15, as requested. Building Name Building # Date Central Cooling On Status Date Window A/C Units installed Status

  1. East Bank District Heating-to-Cooling Conversion Plan Check the date your building's cooling system is scheduled to be on.

    E-Print Network [OSTI]

    Webb, Peter

    East Bank District Heating-to-Cooling Conversion Plan Check the date your building's cooling system is scheduled to be on. Status Color Code: On In Progress Not started Building Name Building # Date Central Cooling On Status Date Window A/C Units installed Status 1425 University Ave. 127 1901 University Ave SE

  2. A comparison of management and leadership skills critical to the principalship as perceived by superintendents in selected independent school districts in Texas

    E-Print Network [OSTI]

    White, Katherine Alia

    2006-04-12T23:59:59.000Z

    by gender and size of district. An e-mail was sent to each superintendent with a web address and an access code. A response rate of 66% was obtained for a sample size of 290 superintendents. The survey contained items on management and leadership skills from...

  3. Accessibility and historic districts: design concepts and economic feasibility study for the downtown historic district of Bryan, Texas

    E-Print Network [OSTI]

    Shamanna, Jayashree B

    1994-01-01T23:59:59.000Z

    This study explores the application of the Americans with Disabilities Act (ADA) to historic districts, and design concepts are proposed to bring the district as a whole into compliance with the ADA. Past studies have dealt with accessibility...

  4. What is District Energy and How Does it Work? District Energy (DE) systems use hot water or

    E-Print Network [OSTI]

    wood used to supply a small district heating plant. The heating plant can be configured to use woody rapeseed oil is used. The district heating grid has a length of 3.3 miles, and the heat delivery is around

  5. New Forestry Commission District Office The new Forestry Commission

    E-Print Network [OSTI]

    New Forestry Commission District Office The new Forestry Commission District office at Smithton in construction The Forestry Commission's District office at Smithton in Inverness, Scotland, covers the national fuel heating system has proved effective during the winter of 2009/10, one of the harshest in 40 years

  6. CONTROL OF SUPPLY TEMPERATURE IN DISTRICT HEATING SYSTEMS

    E-Print Network [OSTI]

    CONTROL OF SUPPLY TEMPERATURE IN DISTRICT HEATING SYSTEMS T.S. Nielsen, H. Madsen Informatics the supply temperature in district heating systems using stochastic modelling, prediction and control at Roskilde Varmeforsyning. The results obtained for the Roskilde district heating utility are evaluated

  7. Predictive control of supply temperature in district heating systems

    E-Print Network [OSTI]

    Predictive control of supply temperature in district heating systems Torben Skov Nielsen Henrik This report considers a new concept for controlling the supply temperature in district heating systems using stochastic modelling, prediction and control. A district heating systems is a di#30;cult system to control

  8. First university owned district heating system using biomass heat

    E-Print Network [OSTI]

    Northern British Columbia, University of

    Highlights · First university owned district heating system using biomass heat · Capacity: 15 MMBtu Main Campus District Heating Performance · Avoided: 3500 tonnes of CO2 · Particulate: less than 10 mg District Heating Goals To displace 85% of natural gas used for core campus heating. Fuel Bunker Sawmill

  9. Codeword Stabilized Quantum Codes

    E-Print Network [OSTI]

    Andrew Cross; Graeme Smith; John A. Smolin; Bei Zeng

    2007-09-27T23:59:59.000Z

    We present a unifying approach to quantum error correcting code design that encompasses additive (stabilizer) codes, as well as all known examples of nonadditive codes with good parameters. We use this framework to generate new codes with superior parameters to any previously known. In particular, we find ((10,18,3)) and ((10,20,3)) codes. We also show how to construct encoding circuits for all codes within our framework.

  10. Generalized Concatenated Quantum Codes

    E-Print Network [OSTI]

    Markus Grassl; Peter Shor; Graeme Smith; John Smolin; Bei Zeng

    2009-01-09T23:59:59.000Z

    We introduce the concept of generalized concatenated quantum codes. This generalized concatenation method provides a systematical way for constructing good quantum codes, both stabilizer codes and nonadditive codes. Using this method, we construct families of new single-error-correcting nonadditive quantum codes, in both binary and nonbinary cases, which not only outperform any stabilizer codes for finite block length, but also asymptotically achieve the quantum Hamming bound for large block length.

  11. Encoding Subsystem Codes

    E-Print Network [OSTI]

    Pradeep Kiran Sarvepalli; Andreas Klappenecker

    2008-06-30T23:59:59.000Z

    In this paper we investigate the encoding of operator quantum error correcting codes i.e. subsystem codes. We show that encoding of subsystem codes can be reduced to encoding of a related stabilizer code making it possible to use all the known results on encoding of stabilizer codes. Along the way we also show how Clifford codes can be encoded. We also show that gauge qubits can be exploited to reduce the encoding complexity.

  12. On optimal constacyclic codes

    E-Print Network [OSTI]

    Giuliano G. La Guardia

    2013-11-11T23:59:59.000Z

    In this paper we investigate the class of constacyclic codes, which is a natural generalization of the class of cyclic and negacyclic codes. This class of codes is interesting in the sense that it contains codes with good or even optimal parameters. In this light, we propose constructions of families of classical block and convolutional maximum-distance-separable (MDS) constacyclic codes, as well as families of asymmetric quantum MDS codes derived from (classical-block) constacyclic codes. These results are mainly derived from the investigation of suitable properties on cyclotomic cosets of these corresponding codes.

  13. Building Energy Code

    Broader source: Energy.gov [DOE]

    The West Virginia State Fire Commission is responsible for adopting and promulgating statewide construction codes. These codes may be voluntarily adopted at the local level. Local jurisdictions...

  14. An Overview of the Operational Characteristics of Selected Irrigation Districts in the Texas Lower Rio Grande Valley: Brownsville Irrigation District

    E-Print Network [OSTI]

    Stubbs, Megan J.; Rister, M. Edward; Sturdivant, Allen W.; Lacewell, Ronald D.

    TR-274 August 2004 An Overview of the Operational Characteristics of Selected Irrigation Districts in the Texas Lower Rio Grande Valley: Brownsville Irrigation District Megan J. Stubbs M. Edward Rister Allen W... Grande Valley: Brownsville Irrigation District Megan J. Stubbs M. Edward Rister Allen W. Sturdivant Ronald D. Lacewell Texas Water Resources Institute Texas A&M University System This research was financially supported...

  15. Calculation of Ramp Response of Lossy Transmission Lines Using Two-port Network Functions

    E-Print Network [OSTI]

    Pedram, Massoud

    1 Calculation of Ramp Response of Lossy Transmission Lines Using Two-port Network Functions Payam-port representation of the transmission line and accounts for the output resistance of the driver and the line response of lossy transmission line which expands the reciprocal of transfer function of the system

  16. Adopted Version 1 Georgia Tech's "BuzzPort" Portal Usage Policy

    E-Print Network [OSTI]

    Li, Mo

    Adopted Version 1 Georgia Tech's "BuzzPort" Portal Usage Policy v. 7.1 1.0 PURPOSE This Policy are highly valued and sensitive Institute resources. This Policy establishes an acceptable usage framework.0 SCOPE This Policy applies to all authorized BuzzPort usage from any location at all times

  17. Welcome to the Port of Duluth-Superior Duluth-Superior

    E-Print Network [OSTI]

    Minnesota, University of

    of capacity for a tandem pick #12;REpower Systems #12;1st Rail Move of Wind Turbine Components via Port to Chile #12;Seamless Transport Blades to Brazil #12;WIND TURBINE COMPONENT SHIPMENTS 2005 ­ 34,080 Freight at Port of Ust-Luga in Russia #12;Super Sacks of Ceramic Proppant for Hydraulic Fracturing headed to North

  18. Biomass cogeneration, Port Townsend, Washington Study by Honors 220c, Energy & Environment,

    E-Print Network [OSTI]

    Biomass cogeneration, Port Townsend, Washington Study by Honors 220c, Energy & Environment, Humans Townsend Biomass Power Plant When considering the slash sources that will be used to fuel the Port Townsend from the current 84,000 dry tons to 184,000 dry tons with the new biomass plant addition (Wise, 2012

  19. The Port Hamiltonian approach to modeling and control of Continuous Stirred Tank Reactors

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    The Port Hamiltonian approach to modeling and control of Continuous Stirred Tank Reactors H. Hoang, Thermodynamics, IDA-PBC control, Chemical reactors. 1 Introduction Port Hamiltonian framework has been pseudo Hamiltonian formula- tion of Continuous Stirred Tank Reactor model in which takes place some

  20. Integrating World Cities into Production Networks: The Case of Port Cities

    E-Print Network [OSTI]

    Boyer, Edmond

    -GVC-GPN and WCN) provide different but complementary analyses of the globalization of the economy. Few studies of the global economy. In this contribution to the special issue, we argue that port cities are an excellentIntegrating World Cities into Production Networks: The Case of Port Cities Published in: Global

  1. Monovalve with integrated fuel injector and port control valve, and engine using same

    DOE Patents [OSTI]

    Milam, David M. (Metamora, IL)

    2002-01-01T23:59:59.000Z

    Each cylinder of an internal combustion engine includes a combined gas exchange valve and fuel injector with a port control valve. The port control valve operates to open either an intake passage or an exhaust passage. The operation of the combined device is controlled by a pair of electrical actuators. The device is hydraulically actuated.

  2. Optical Monte Carlo modeling of a true port wine stain anatomy

    E-Print Network [OSTI]

    Barton, Jennifer K.

    of accommodating an arbitrarily complex geometry was used to determine the energy deposition in a true port wineOptical Monte Carlo modeling of a true port wine stain anatomy Jennifer Kehlet Barton, T. Joshua nm. At both wavelengths, the greatest energy deposition occurred in the superficial blood vessels

  3. Computational model to evaluate port wine stain depth profiling using pulsed photothermal radiometry

    E-Print Network [OSTI]

    Choi, Bernard

    Computational model to evaluate port wine stain depth profiling using pulsed photothermal-thermal model to evaluate the use of pulsed photothermal radiometry (PPTR) for depth profiling of port wine the desired effect. A diagnostic measurement of the distribution of laser energy deposition and ensuing

  4. Numerical modeling of spray cooling-assisted dermatologic laser surgery for treatment of port wine stains

    E-Print Network [OSTI]

    Aguilar, Guillermo

    Numerical modeling of spray cooling-assisted dermatologic laser surgery for treatment of port wine to the epidermis during dermatologic laser surgery (DLS) for removal of port wine stain (PWS) birthmarks heat (J/kg/K) c speed of light in i (m/s) D optical diffusion coefficient (m) Ea activation energy

  5. Port of Houston Intermodal Grain Transfer System and Market Area, 1976 - 1977. 

    E-Print Network [OSTI]

    Fuller, Stephen W.; Paggi, Mechel S.

    1978-01-01T23:59:59.000Z

    Railroads ................................................. 4 Trucks .................................................. 7 Ships ................................................... 7 Grain Elevators ........................................... 10 Port... of the receipts were from Oklahoma. lowa, raska, and Kansas shipped 15, 1 1, and 10 percent of e Port's respective grain and soybean inflow. Texas ranked first as an originator of grain sorghum (59%) and second as a source of wheat (3 1%) and soybeans (35...

  6. Port-Hamiltonian systems: network modeling and control of nonlinear physical systems

    E-Print Network [OSTI]

    Schaft, Arjan van der

    Port-Hamiltonian systems: network modeling and control of nonlinear physical systems A.J. van der systems (multi-body systems, electrical circuits, electromechanical systems, ..) naturally leads to a geometrically defined class of systems, called port-Hamiltonian systems. These are Hamiltonian systems defined

  7. Complete three photon Hong-Ou-Mandel interference at a three port device

    E-Print Network [OSTI]

    S. Mährlein; J. von Zanthier; G. S. Agarwal

    2015-03-19T23:59:59.000Z

    We report the possibility of completely destructive interference of three indistinguishable photons on a three port device providing a generalisation of the well known Hong-Ou-Mandel interference of two indistinguishable photons on a two port device. Our analysis is based on the underlying mathematical framework of SU(3) transformations rather than SU(2) transformations. We show the completely destructive three photon interference for a large range of parameters of the three port device. As each output port can deliver zero to three photons the device generates higher dimensional entanglement. In particular, different forms of entangled states of qudits can be generated depending again on the device parameters. Our system is different from a symmetric three port beam splitter which does not exhibit a three photon Hong-Ou-Mandel interference.

  8. Review of the independent risk assessment of the proposed Cabrillo liquified natural gas deepwater port project.

    SciTech Connect (OSTI)

    Gritzo, Louis Alan; Hightower, Marion Michael; Covan, John Morgan; Luketa-Hanlin, Anay Josephine

    2006-01-01T23:59:59.000Z

    In March 2005, the United States Coast Guard requested that Sandia National Laboratories provide a technical review and evaluation of the appropriateness and completeness of models, assumptions, analyses, and risk management options presented in the Cabrillo Port LNG Deepwater Port Independent Risk Assessment-Revision 1 (Cabrillo Port IRA). The goal of Sandia's technical evaluation of the Cabrillo Port IRA was to assist the Coast Guard in ensuring that the hazards to the public and property from a potential LNG spill during transfer, storage, and regasification operations were appropriately evaluated and estimated. Sandia was asked to review and evaluate the Cabrillo Port IRA results relative to the risk and safety analysis framework developed in the recent Sandia report, ''Guidance on Risk Analysis and Safety Implications of a Large Liquefied Natural Gas (LNG) Spill over Water''. That report provides a framework for assessing hazards and identifying approaches to minimize the consequences to people and property from an LNG spill over water. This report summarizes the results of the Sandia review of the Cabrillo Port IRA and supporting analyses. Based on our initial review, additional threat and hazard analyses, consequence modeling, and process safety considerations were suggested. The additional analyses recommended were conducted by the Cabrillo Port IRA authors in cooperation with Sandia and a technical review panel composed of representatives from the Coast Guard and the California State Lands Commission. The results from the additional analyses improved the understanding and confidence in the potential hazards and consequences to people and property from the proposed Cabrillo Port LNG Deepwater Port Project. The results of the Sandia review, the additional analyses and evaluations conducted, and the resolutions of suggested changes for inclusion in a final Cabrillo Port IRA are summarized in this report.

  9. An analytic-deliberative process for the selection and deployment of radiation detection systems for shipping ports and border crossings

    E-Print Network [OSTI]

    Shattan, Michael B

    2008-01-01T23:59:59.000Z

    Combating the threat of nuclear smuggling through shipping ports and border crossings has been recognized as a national priority in defending the US against nuclear terrorism. In light of the SAFE Port act of 2006, the ...

  10. Effect of fuel properties on the first cycle fuel delivery in a Port Fuel Injected Spark Ignition Engine

    E-Print Network [OSTI]

    Lang, Kevin R., 1980-

    2004-01-01T23:59:59.000Z

    Achieving robust combustion while also yielding low hydrocarbon (HC) emissions is difficult for the first cycle of cranking during the cold start of a Port Fuel Injected (PFI) Spark Ignition (SI) engine. Cold intake port ...

  11. Assessing the Environmental and Health Impacts of Port-Related Freight Movement in a Major Urban Transportation Corridor

    E-Print Network [OSTI]

    2010-01-01T23:59:59.000Z

    NO X for port trucks, line-haul, and railyards for winterhaul movements. Compared to PM and NO X emission from port truckshaul distance and speed of locomotives are used. After estimating emissions for both trains and drayage trucks

  12. Generalized Concatenation for Quantum Codes

    E-Print Network [OSTI]

    Markus Grassl; Peter W. Shor; Bei Zeng

    2009-05-04T23:59:59.000Z

    We show how good quantum error-correcting codes can be constructed using generalized concatenation. The inner codes are quantum codes, the outer codes can be linear or nonlinear classical codes. Many new good codes are found, including both stabilizer codes as well as so-called nonadditive codes.

  13. Report to Congress on Server and Data Center Energy Efficiency: Public Law 109-431: Appendices

    E-Print Network [OSTI]

    Brown, Richard; Alliance to Save Energy; ICF Incorporated; ERG Incorporated; U.S. Environmental Protection Agency

    2008-01-01T23:59:59.000Z

    school districts, ports, libraries, hospitals, and health districts which provides free energy audits.

  14. Graph concatenation for quantum codes

    E-Print Network [OSTI]

    Beigi, Salman

    Graphs are closely related to quantum error-correcting codes: every stabilizer code is locally equivalent to a graph code and every codeword stabilized code can be described by a graph and a classical code. For the ...

  15. Energy shaping of port-Hamiltonian systems by using alternate passive Aneesh Venkatraman and Arjan van der Schaft

    E-Print Network [OSTI]

    Schaft, Arjan van der

    Energy shaping of port-Hamiltonian systems by using alternate passive outputs Aneesh Venkatraman the energy in a desired manner. I. INTRODUCTION Port-Hamiltonian models [1] encompass a very large class storage elements and are characterized by a set of energy-storing elements, resistive ports and external

  16. CONCATENATED CODES BASED ON MULTIDIMENSIONAL PARITY-CHECK CODES AND TURBO CODES

    E-Print Network [OSTI]

    Wong, Tan F.

    CONCATENATED CODES BASED ON MULTIDIMENSIONAL PARITY-CHECK CODES AND TURBO CODES John M. Shea, Florida Abstract--Turbo-codes provide communications near capac- ity when very large interleavers (and parity-check code can be used as an outer code with a turbo code as an inner code in a serial

  17. Impact of access port diameter on the long reach manipulator design

    SciTech Connect (OSTI)

    Stoughton, R.S.

    1994-04-01T23:59:59.000Z

    Many of the single shell storage tanks (SSTs) on the Hanford site appear to have central 42-in. risers which could be used as access ports for the Long Reach Manipulator (LRM). However, about half of the tanks are known to not have a central 42-in. riser and it has recently been discovered that of the tanks whose drawings indicate central 42-in. risers, the majority have been plugged, sealed, or taper down to a much smaller diameter at ground level. Thus, it can be assumed that a central access port for the LRM will have to be made. There are many issues involved in determining the best diameter for this access port such as radiation exposure, contamination prevention, and availability of remote excavation technology. This report analyzes the relationship between the access port diameter and the performance characteristics of the LRM. Previous work has assumed that the mast diameter would be 80% of the access port diameter. In this report, the maximum mast diameter will be varied rather than the access port diameter, leaving the issue of the required clearance between the mast and the access port open.

  18. Complications of Transfemoral Removal of Percutaneous Transfemorally Implanted Port-Catheter Systems

    SciTech Connect (OSTI)

    Yahiro, Yoshiyuki; Toyota, Naoyuki, E-mail: naotoyo@hiroshima-u.ac.jp; Kakizawa, Hideaki; Hieda, Masashi; Hirai, Nobuhiko; Naito, Akira; Ito, Katsuhide [Programs for Applied Biomedicine, Graduate School of Biomedical Science, Hiroshima University, Department of Radiology, Division of Medical Intelligence and Informatics (Japan)

    2006-10-15T23:59:59.000Z

    Our purpose is to evaluate the feasibility and safety of the withdrawal procedure of percutaneous transfemorally implanted port-catheter systems. Thirty-seven patients (17.7%) underwent the withdrawal procedure of this port-catheter system among 209 patients. The reasons for withdrawal were as follows: termination of intra-arterial chemotherapy (n = 7), obstruction of hepatic artery (n = 5), port infection (n = 4), catheter infection (n = 4), catheter obstruction (n = 4), lower-limb palsy and pain (n = 2), exposure of the port due to skin defect (n = 2), patient's desire (n = 2), side effect of chemotherapy (n = 1), no effectiveness of chemotherapy (n = 1), hematoma at the puncture site (n = 1), duodenum perforation by the catheter (n = 1), intermittent claudication due to severe stenosis of right common iliac artery (n = 1), dissection of common hepatic artery (n = 1), and broken catheter (n = 1). In thirty-four of the 37 cases, the port-catheter system was successfully withdrawn without any complications. Clinical success rate was 91.9%. Complications occurred in three cases (8.1%), which were a pseudoaneurysm, thromboembolism of the right common iliac artery, and continuous bleeding from the subcutaneous pocket where the port system was placed for 1 month. In 15 cases, correction of the catheter tip or exchange for dislocation of the tip had to be done without withdrawal. It is not rare to withdraw port-catheter systems in cases of infection or hematoma around the system. Although withdrawal of a percutaneous transfemorally implanted port-catheter system is a relatively safe procedure, the port-catheter system should not be removed unless absolutely indicated.

  19. Joint Source-Channel Coding via Turbo Codes

    E-Print Network [OSTI]

    Alajaji, Fady

    Joint Source-Channel Coding via Turbo Codes by Guang-Chong Zhu A dissertation submitted coding. One of the most exciting break- throughs in channel coding is the invention of Turbo codes, whose- tigate three joint source-channel coding issues in the context of Turbo codes. In the #12;rst part

  20. Texas Legislative and Irrigation Districts of the Rio Grande River Basin: A Map Series 

    E-Print Network [OSTI]

    Leigh, Eric; Fipps, G.

    2008-01-01T23:59:59.000Z

    Improvement District No.3 HCWID3 La Feria Irrigation District-Cameron County No.3 La Feria Santa Cruz Irrigation District No.15 Santa Cruz Santa Maria Irrigation District-Cameron County No.4 Santa Maria United Irrigation District of Hidalgo County United....6 34,913 Hidalgo County Municipal Utility District No.1 1,120 Hidalgo County Water Improvement District No.3 9,753 La Feria Irrigation District-Cameron County No.3 75,626 Santa Cruz Irrigation District No.15 75,080 Santa Maria Irrigation...

  1. Texas Legislative and Irrigation Districts of the Rio Grande River Basin: A Map Series

    E-Print Network [OSTI]

    Leigh, Eric; Fipps, G.

    Improvement District No.3 HCWID3 La Feria Irrigation District-Cameron County No.3 La Feria Santa Cruz Irrigation District No.15 Santa Cruz Santa Maria Irrigation District-Cameron County No.4 Santa Maria United Irrigation District of Hidalgo County United....6 34,913 Hidalgo County Municipal Utility District No.1 1,120 Hidalgo County Water Improvement District No.3 9,753 La Feria Irrigation District-Cameron County No.3 75,626 Santa Cruz Irrigation District No.15 75,080 Santa Maria Irrigation...

  2. Unfolding the color code

    E-Print Network [OSTI]

    Aleksander Kubica; Beni Yoshida; Fernando Pastawski

    2015-03-06T23:59:59.000Z

    The topological color code and the toric code are two leading candidates for realizing fault-tolerant quantum computation. Here we show that the color code on a $d$-dimensional closed manifold is equivalent to multiple decoupled copies of the $d$-dimensional toric code up to local unitary transformations and adding or removing ancilla qubits. Our result not only generalizes the proven equivalence for $d=2$, but also provides an explicit recipe of how to decouple independent components of the color code, highlighting the importance of colorability in the construction of the code. Moreover, for the $d$-dimensional color code with $d+1$ boundaries of $d+1$ distinct colors, we find that the code is equivalent to multiple copies of the $d$-dimensional toric code which are attached along a $(d-1)$-dimensional boundary. In particular, for $d=2$, we show that the (triangular) color code with boundaries is equivalent to the (folded) toric code with boundaries. We also find that the $d$-dimensional toric code admits logical non-Pauli gates from the $d$-th level of the Clifford hierarchy, and thus saturates the bound by Bravyi and K\\"{o}nig. In particular, we show that the $d$-qubit control-$Z$ logical gate can be fault-tolerantly implemented on the stack of $d$ copies of the toric code by a local unitary transformation.

  3. List decoding of subspace codes and rank-metric codes

    E-Print Network [OSTI]

    Mahdavifar, Hessam

    2012-01-01T23:59:59.000Z

    2.2.2 Koetter-Kschischang Codes . . . . . . . . . . . .of Subspace Codes . . . . . . . . . . . . . . 2.3.1 OverviewList-decodable Codes of Arbitrary Dimension . . . . . . .

  4. Building Energy Code

    Broader source: Energy.gov [DOE]

    ''Much of the information presented in this summary is drawn from the U.S. Department of Energy’s (DOE) Building Energy Codes Program and the Building Codes Assistance Project (BCAP). For more...

  5. Model Building Energy Code

    Broader source: Energy.gov [DOE]

    ''Much of the information presented in this summary is drawn from the U.S. Department of Energy’s (DOE) Building Energy Codes Program and the Building Codes Assistance Project (BCAP). For more...

  6. Compiling Codes on Euclid

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Compiling Codes Compiling Codes Overview Open Mpi is the the only MPI library available on Euclid. This implementation of MPI-2 is described at Open MPI: Open Source High...

  7. Coding AuthentiCity

    E-Print Network [OSTI]

    Mercier, Rachel Havens

    2008-01-01T23:59:59.000Z

    This thesis analyzes the impact of form-based codes, focusing on two research questions: (1) What is the underlying motivation for adopting a form-based code? (2) What motivations have the most significant impact on ...

  8. Introduction to Algebraic Codes

    E-Print Network [OSTI]

    for health care. These self-correcting codes that occur in nature might be better than all of. our coding theory based on algebra or algebraic geometry. It is a myth

  9. Building Energy Code

    Broader source: Energy.gov [DOE]

    Note: Much of the information presented in this summary is drawn from the U.S. Department of Energy’s (DOE) Building Energy Codes Program and the Building Codes Assistance Project (BCAP). For more...

  10. Building Energy Code

    Broader source: Energy.gov [DOE]

    ''Note: Much of the information presented in this summary is drawn from the U.S. Department of Energy’s (DOE) Building Energy Codes Program and the Building Codes Assistance Project (BCAP). For...

  11. Cellulases and coding sequences

    DOE Patents [OSTI]

    Li, Xin-Liang (Athens, GA); Ljungdahl, Lars G. (Athens, GA); Chen, Huizhong (Lawrenceville, GA)

    2001-02-20T23:59:59.000Z

    The present invention provides three fungal cellulases, their coding sequences, recombinant DNA molecules comprising the cellulase coding sequences, recombinant host cells and methods for producing same. The present cellulases are from Orpinomyces PC-2.

  12. Building Energy Code

    Broader source: Energy.gov [DOE]

    The New Jersey Uniform Construction Code Act provides that model codes and standards publications shall not be adopted more frequently than once every three years. However, a revision or amendment...

  13. Building Energy Code

    Broader source: Energy.gov [DOE]

    All residential and commercial structures are required to comply with the state’s energy code. The 2009 New Mexico Energy Conservation Code (NMECC), effective June 2013, is based on 2009...

  14. Building Energy Code

    Broader source: Energy.gov [DOE]

    Prior to 1997, South Carolina's local governments adopted and enforced the building codes. In 1997, the law required statewide use of the most up-to-date building codes, which then required the...

  15. Coding for Cooperative Communications

    E-Print Network [OSTI]

    Uppal, Momin Ayub

    2011-10-21T23:59:59.000Z

    of SWCNSQ based CF relaying as a performance benchmark, we will present a practical code design using low-density parity-check (LDPC) codes for error protection at the source, and nested scalar quantization plus irregular repeat-accumulate (IRA) codes... develop and design practical coding strategies which perform very close to the infor- mation theoretic limits. The cooperative communication channels we consider are: (a) The Gaussian re- lay channel, (b) the quasi-static fading relay channel, (c...

  16. Central Lincoln People's Utility District- Renewable Energy Incentive Program

    Broader source: Energy.gov [DOE]

    Central Lincoln People's Utility District provides financial incentives for its commercial and residential customers to install photovoltaic (PV), solar water heating, wind, and hydro electric...

  17. Empire District Electric- Commercial and Industrial Efficiency Rebates

    Broader source: Energy.gov [DOE]

    Empire District Electric Company offers rebates to certain commercial and industrial customers for the installation of energy efficiency equipment. Prescriptive rebates for lighting, air...

  18. Cedarville School District Retrofit of Heating and Cooling Systems...

    Open Energy Info (EERE)

    Jump to: navigation, search Last modified on July 22, 2011. Project Title Cedarville School District Retrofit of Heating and Cooling Systems with Geothermal Heat Pumps and Ground...

  19. Microsoft PowerPoint - Vicksburg District Federal Power Projects...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Federal Power Projects Vicksburg District Federal Power Projects Blakely Mountain Hydro DeGray Hydro DeGray Hydro Narrows Hydro Blakely Mountain Rewind Unit 1 ll Rotor...

  20. New York State Capital District Regional Middle School Science...

    Office of Science (SC) Website

    New York State Capital District Regional Middle School Science Bowl National Science Bowl (NSB) NSB Home About High School Middle School Middle School Students Middle School...

  1. BUSINESS SENSITIVE 1 Tri-Cities Research District

    E-Print Network [OSTI]

    BUSINESS SENSITIVE 1 Tri-Cities Research District Speaker Series: Advancing Research Parks from National Developers · Strategies for Pro-active Outreach Marketing #12;BUSINESS SENSITIVE 5

  2. Geothermal: Sponsored by OSTI -- Berlin, Maryland district heating...

    Office of Scientific and Technical Information (OSTI)

    Berlin, Maryland district heating assessment project Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us HomeBasic Search About Publications Advanced...

  3. Charles County- Agricultural Preservation Districts- Renewable Generation Allowed

    Broader source: Energy.gov [DOE]

    Charles County provides that producing energy "from solar, wind, biomass, and farm waste and residue crops" is a permitted agricultural use in areas zoned as Agricultural Preservation Districts.

  4. Central Lincoln People's Utility District- Residential Energy Efficiency Rebate Programs

    Broader source: Energy.gov [DOE]

    Central Lincoln People's Municipal Utility District (CLPUD) offers a variety of energy efficiency programs for residential customers to save energy in eligible homes. Rebates are available for...

  5. Central Lincoln People's Utility District- Renewable Energy Incentive Program (Oregon)

    Broader source: Energy.gov [DOE]

    Central Lincoln People's Utility District provides financial incentives for its commercial and residential customers to install photovoltaic (PV), solar water heating, wind, and hydro electric...

  6. Omaha Public Power District- Commercial Energy Efficiency Rebate Programs

    Broader source: Energy.gov [DOE]

    Omaha Public Power District (OPPD) offers incentives for commercial and industrial customers to install energy-efficient heat pumps and replace/retrofit existing lighting systems. The Commercial...

  7. Nebraska Public Power District- Commercial Energy Efficiency Rebate Programs

    Broader source: Energy.gov [DOE]

    Nebraska Public Power District offers multiple rebates for commercial and industrial customers to save energy in eligible facilities. Rebates are available for energy efficient lighting, HVAC...

  8. Lassen Municipal Utility District- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Lassen Municipal Utility District (LMUD) offers an incentive for residential customers who purchase and install efficient lighting, HVAC equipment and ENERGY STAR rated appliances for eligible...

  9. Empire District Electric- Residential Energy Efficiency Rebate Program (Arkansas)

    Broader source: Energy.gov [DOE]

    Empire District Electric Company (EDEC) offers rebates to residential customers for energy audits, weatherization measures, central air conditioning systems, and energy efficient home appliances....

  10. Omaha Public Power District- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Omaha Public Power District (OPPD) offers energy credit refunds to its residential customers for installing high-efficiency heat pumps through the Energy Conservation Program. Newly constructed...

  11. Modesto Irrigation District- New Home Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Modesto Irrigation District's MPower New Home Program provides incentives to builders and homeowners for designing and building energy-efficient homes. Eligible homes must meet the guidelines for...

  12. Turlock Irrigation District- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Turlock Irrigation District (TID) offers a residential rebate program for customers who install energy-efficient equipment in their homes. Eligible equipment includes

  13. Vera Irrigation District #15- Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Vera Irrigation District #15 offers rebates to electric customers who improve energy efficiency. Rebates are available for water heaters, windows, heat pumps, clothes washer, duct sealing and...

  14. area purulia district: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Downtown Revitalization Industrial Park Improvements Housing and Disaster Recovery Brownfield Redevelopment and identifies the changing needs of the District's communities and...

  15. area surguja district: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Downtown Revitalization Industrial Park Improvements Housing and Disaster Recovery Brownfield Redevelopment and identifies the changing needs of the District's communities and...

  16. area ganjam district: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Downtown Revitalization Industrial Park Improvements Housing and Disaster Recovery Brownfield Redevelopment and identifies the changing needs of the District's communities and...

  17. area dharmapuri district: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Downtown Revitalization Industrial Park Improvements Housing and Disaster Recovery Brownfield Redevelopment and identifies the changing needs of the District's communities and...

  18. Truckee Donner Public Utility District- Energy Conservation Rebate Program

    Broader source: Energy.gov [DOE]

    Truckee Donner Public Utility District (TDPUD) offers incentives for customers to improve the energy efficiency of homes and businesses. Participants must be a TDPUD electric customer (and water...

  19. Magnetic Modeling Of The Phlegraean Volcanic District With Extension...

    Open Energy Info (EERE)

    Archipelago, Italy Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article: Magnetic Modeling Of The Phlegraean Volcanic District With Extension To The...

  20. Pepco and PJM Interconnection Comments on District of Columbia...

    Energy Savers [EERE]

    Pepco and PJM Interconnection Comments on District of Columbia Public Service Commission, Docket No. EO-05-01 Comments and Answer to Requests for Rehearing Pepco and PJM...

  1. Homological Product Codes

    E-Print Network [OSTI]

    Sergey Bravyi; Matthew B. Hastings

    2013-11-04T23:59:59.000Z

    Quantum codes with low-weight stabilizers known as LDPC codes have been actively studied recently due to their simple syndrome readout circuits and potential applications in fault-tolerant quantum computing. However, all families of quantum LDPC codes known to this date suffer from a poor distance scaling limited by the square-root of the code length. This is in a sharp contrast with the classical case where good families of LDPC codes are known that combine constant encoding rate and linear distance. Here we propose the first family of good quantum codes with low-weight stabilizers. The new codes have a constant encoding rate, linear distance, and stabilizers acting on at most $\\sqrt{n}$ qubits, where $n$ is the code length. For comparison, all previously known families of good quantum codes have stabilizers of linear weight. Our proof combines two techniques: randomized constructions of good quantum codes and the homological product operation from algebraic topology. We conjecture that similar methods can produce good stabilizer codes with stabilizer weight $n^a$ for any $a>0$. Finally, we apply the homological product to construct new small codes with low-weight stabilizers.

  2. Port Angeles Public Works and Utilities- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Port Angeles Public Works and Utilities offers a rebate program to encourage residential customers to increase the energy efficiency of their homes. The rebates apply to qualifying installations in...

  3. The Effects Of Port Security Compliance On The Competitiveness Of European Union Maritime Industry Firms

    E-Print Network [OSTI]

    Stone, Jonathan Taylor

    2013-02-12T23:59:59.000Z

    ABSTRACT The Effects Of Port Security Compliance On The Competitiveness Of European Union Maritime Industry Firms. (May 2013) Jonathan Stone Department of Maritime Administration Texas A&M University Research Advisor: Dr. Joan Mileski Department...

  4. Microsoft Word - CX-PortAngeles-Sappho-AR-FY13_WEB.doc

    Broader source: Energy.gov (indexed) [DOE]

    3 REPLY TO ATTN OF: KEP-4 SUBJECT: Environmental Clearance Memorandum Rick Ross Project Manager - TELF-TPP-3 Proposed Action: Access road maintenance on the Port Angeles-Sappho No....

  5. Service identification in TCP/IP : well-known versus random port numbers

    E-Print Network [OSTI]

    Masiello, Elizabeth

    2005-01-01T23:59:59.000Z

    The sixteen-bit well-known port number is often overlooked as a network identifier in Internet communications. Its purpose at the most fundamental level is only to demultiplex flows of traffic. Several unintended uses of ...

  6. A visualization study of mixture preparation mechanisms for port fuel injected spark ignition engines

    E-Print Network [OSTI]

    Costanzo, Vincent S. (Vincent Stanley), 1979-

    2004-01-01T23:59:59.000Z

    An experimental study was carried out that examined qualitatively the mixture preparation process in port fuel injected spark ignition engines. The primary variables in this study were intake valve lift, intake valve timing, ...

  7. Understanding Perception Through Neural 'Codes'

    E-Print Network [OSTI]

    Freeman, Walter J III

    2011-01-01T23:59:59.000Z

    Perception Through Neural ‘Codes’. In: Special Issue on “Perception Through Neural ‘Codes’. In: Special Issue on “Perception Through Neural ‘Codes’. In: Special Issue on “

  8. Programmable two-port polarization independent electro-optically tunable wavelength filter in lithium niobate

    E-Print Network [OSTI]

    Ping, Yang

    2009-05-15T23:59:59.000Z

    PROGRAMMABLE TWO-PORT POLARIZATION INDEPENDENT ELECTRO-OPTICALLY TUNABLE WAVELENGTH FILTER IN LITHIUM NIOBATE A Dissertation by YANG PING Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment... of the requirements for the degree of DOCTOR OF PHILOSOPHY December 2006 Major Subject: Electrical Engineering PROGRAMMABLE TWO-PORT POLARIZATION INDEPENDENT ELECTRO-OPTICALLY TUNABLE WAVELENGTH FILTER IN LITHIUM NIOBATE A Dissertation by YANG...

  9. Cool Trends in District Energy: A Survey of Thermal Energy Storage...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    in District Energy: A Survey of Thermal Energy Storage Use in District Energy Utility Applications, June 2005 Cool Trends in District Energy: A Survey of Thermal Energy Storage Use...

  10. Real-Time Water Quality Management in the Grassland Water District

    E-Print Network [OSTI]

    2004-01-01T23:59:59.000Z

    Grassland Water District. Solar Panel with 12-volt batteryWater District. Power Solar Panel with 12-volt batteryWater District. Power Solar Panel with 12-volt battery

  11. Removal of Historic Low-Level Radioactive Sediment from the Port Hope Harbour - 13314

    SciTech Connect (OSTI)

    Kolberg, Mark [Baird and Associates, 1267 Cornwall Rd., Suite 100, Oakville ON, L6J7T5 (Canada)] [Baird and Associates, 1267 Cornwall Rd., Suite 100, Oakville ON, L6J7T5 (Canada); Case, Glenn [Atomic Energy of Canada Limited, Port Hope, ON (Canada)] [Atomic Energy of Canada Limited, Port Hope, ON (Canada); Ferguson Jones, Andrea [MMM Group Limited, Thornhill, ON (Canada)] [MMM Group Limited, Thornhill, ON (Canada)

    2013-07-01T23:59:59.000Z

    At the Port Hope Harbour, located on the north shore of Lake Ontario, the presence of low-level radioactive sediment, resulting from a former radium and uranium refinery that operated alongside the Harbour, currently limits redevelopment and revitalization opportunities. These waste materials contain radium-226, uranium, arsenic and other contaminants. Several other on-land locations within the community of Port Hope are also affected by the low-level radioactive waste management practices of the past. The Port Hope Project is a community initiated undertaking that will result in the consolidation of an estimated 1.2 million cubic metres of the low-level radioactive waste from the various sites in Port Hope into a new engineered above ground long-term waste management facility. The remediation of the estimated 120,000 m{sup 3} of contaminated sediments from the Port Hope Harbour is one of the more challenging components of the Port Hope Project. Following a thorough review of various options, the proposed method of contaminated sediment removal is by dredging. The sediment from the dredge will then be pumped as a sediment-water slurry mixture into geo-synthetic containment tubes for dewatering. Due to the hard substrate below the contaminated sediment, the challenge has been to set performance standards in terms of low residual surface concentrations that are attainable in an operationally efficient manner. (authors)

  12. SEDIMENT DECONTAMINATION WITH BENEFICIAL USE FOR THE PORT OF NEW YORK AND NEW JERSEY.

    SciTech Connect (OSTI)

    STERN,E.A.; JONES,K.W.; DOUGLAS,W.S.; FENG,H.; CLESCERI,N.L.; LODGE,J.L.

    2002-05-01T23:59:59.000Z

    Effective operation of the multi-state Port ofNew York/New Jersey (Port), which contributes $20 billion to the regional economy and generates nearly 250,000 jobs, is dependent on yearly navigational dredging of several million m{sup 3} of sediment for channel maintenance and deepening. Further dredging is required for remediation of environmentally sensitive areas. However, more stringent ocean placement testing regulations in the Port region have necessitated a search for other means of handling the most contaminated dredged materials. Here, we describe a dredged material decontamination program for the Port aimed at the creation of sediment decontamination facilities that produce a beneficial use product to obviate the need for ocean placement. These facilities, to be a viable component of an overall dredged material management plan, must be environmentally balanced and economically feasible with the predictable ability to process large volumes of dredged materials with rapid turn-around. Our program recognizes that the responsible management of contaminated dredged materials is a complex problem that requires the effective application and coordination of a variety of cross-cutting skills to make decontamination facilities a reality. Participants do not come from a single agency, but are ad hoc teams of scientists, engineers, regulators, port authorities and operators, technology development firms, federal/state/local governments, business interests and community groups, among others, who are brought together by the need to solve the complex problem of managing dredged material in the Port region.

  13. Stakeholder identification of advanced technology opportunities at international ports of entry

    SciTech Connect (OSTI)

    Parker, S.K. [Sandia National Labs., Albuquerque, NM (United States). Energy Policy and Planning Dept.; Icerman, L. [Icerman and Associates, Santa Fe, NM (United States)

    1997-01-01T23:59:59.000Z

    As part of the Advanced Technologies for International and Intermodal Ports of Entry (ATIPE) Project, a diverse group of stakeholders was engaged to help identify problems experienced at inland international border crossings, particularly those at the US-Mexican border. The fundamental issue at international ports of entry is reducing transit time through the required documentation and inspection processes. Examples of other issues or problems, typically manifested as time delays at border crossings, repeatedly mentioned by stakeholders include: (1) lack of document standardization; (2) failure to standardize inspection processes; (3) inadequate information and communications systems; (4) manual fee and tariff collection; (5) inconsistency of processes and procedures; and (6) suboptimal cooperation among governmental agencies. Most of these issues can be addressed to some extent by the development of advanced technologies with the objective of allowing ports of entry to become more efficient while being more effective. Three categories of technologies were unambiguously of high priority to port of entry stakeholders: (1) automated documentation; (2) systems integration; and (3) vehicle and cargo tracking. Together, these technologies represent many of the technical components necessary for pre-clearance of freight approaching international ports of entry. Integration of vehicle and cargo tracking systems with port of entry information and communications systems, as well as existing industry legacy systems, should further enable border crossings to be accomplished consistently with optimal processing times.

  14. Venous Access Ports: Indications, Implantation Technique, Follow-Up, and Complications

    SciTech Connect (OSTI)

    Walser, Eric M., E-mail: walser.eric@mayo.edu [Mayo Clinic, Department of Radiology (United States)

    2012-08-15T23:59:59.000Z

    The subcutaneous venous access device (SVAD or 'port') is a critical component in the care of patients with chronic disease. The modern SVAD provides reliable access for blood withdrawal and medication administration with minimal disruption to a patient's lifestyle. Because of improved materials and catheter technology, today's ports are lighter and stronger and capable of high-pressure injections of contrast for cross-sectional imaging. The majority of SVAD placement occurs in interventional radiology departments due to their ability to provide this service at lower costs, lower, complication rates, and greater volumes. Port-insertion techniques vary depending on the operator, but all consist of catheter placement in the central venous circulation followed by subcutaneous pocket creation and port attachment to the catheter with fixation and closure of the pocket. Venous access challenges occasionally occur in patients with central vein occlusions, necessitating catheterization of collateral veins or port placement in alternate locations. Complications of SVADs include those associated with the procedure as well as short- (<30 days) and long-term problems. Procedural and early complications are quite rare due to the near-universal use of real-time ultrasound guidance for vein puncture, but they can include hematoma, catheter malposition, arrhythmias, and pneumothorax. Late problems include both thrombotic complications (native venous or port-catheter thrombosis) and infections (tunnel or pocket infections or catheter-associated bloodstream infections). Most guidelines suggest that 0.3 infections/1000 catheter days is an appropriate upper threshold for the insertion of SVADs.

  15. Questions about Groundwater Conservation Districts in Texas

    E-Print Network [OSTI]

    Lesikar, Bruce J.; Silvy, Valeen

    2008-09-22T23:59:59.000Z

    activities with export fees? 25 What is the minimum usage rate before fees are charged? 25 Who pays if a GCD is voted in, but the financing is not approved? 25 Who pays for the GCD organizational expenses? 25 Are directors paid for their position? 25... sold and exported beyond district boundaries? 27 Can a GCD prevent a city from moving water from a rural area to an urban area? 27 Can the GCD impose a fee for water exportation? 29 GCD alternatives 29 What happens if we don?t form a GCD? 29 Can we...

  16. District Energy Technologies | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you0andEnergyGlobal Nuclearof aDepartment-ofBenefitsDistrict Energy

  17. Empire District Electric Co | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand JumpConceptual Model,DOEHazel Crest,Energy InformationEmily, Minnesota:Emmons LakeEmpire District

  18. Vera Irrigation District | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty Edit withTianlin BaxinUmwelt ManagementVera Irrigation District Jump to: navigation,

  19. Shortened Turbo Codes

    E-Print Network [OSTI]

    David J.C. MacKay

    Simple arguments suggest that shortened codes must have distance properties equal to or better than those of their parent codes, and that they should be equally practical to decode. This relationship holds true in the case of low density generator codes and low density parity check codes. We investigate the properties of shortened turbo codes. I. Motivation for Shortening In our previous work on codes based on very sparse matrices we have observed that while codes with a low density generator matrix [1] are asymptotically bad, codes with a low density parity check matrix [2] are asymptotically good [3, 4, 5]. One way of viewing the relationship between low density generator matrix codes and low density parity check matrix codes is that one obtains a low density parity check matrix by taking the M \\Theta N parity check matrix [P IM ] of a (N; K) low density generator matrix code and chopping off its right-most M columns (where M = N \\Gamma K), to yield an M \\Theta K matrix [P], which...

  20. Preliminary survey report: control technology for brake lining at Northwest Local School District, Cincinnati, Ohio

    SciTech Connect (OSTI)

    Cooper, T.C.; McGlothlin, J.D.; Godbey, F.W.; Sheehy, J.W.; O'Brien, D.M.

    1986-05-01T23:59:59.000Z

    A walk-through survey of control technology for reducing asbestos exposure during maintenance and repair of vehicular brakes was conducted at Northwest Local School District, Cincinnati, Ohio in January, 1986. The primary method for controlling and collecting dust during brake servicing was a wet-washing technique and good work practices, ensuring that exposure to hazardous physical or chemical agents was reduced or eliminated. Also available was an enclosed-type brake assembly cleaner designed to be connected to the shop air and a vacuum system. The brake assembly cleaner did not have a viewing port to examine the area being cleaned. The operator had to remove the unit to inspect the cleaned area potentially exposing himself to any dust remaining on the brake shoes or hub. The unit itself was a potential dust source as it was designed to fit 16-inch wheels and did not form a tight seal on the smaller 15-inch wheels of the newer buses. The authors conclude that the wet wash technique is an excellent method for controlling asbestos emissions during brake maintenance. The vacuum brake-assembly cleaner is inadequate and potentially hazardous. An in-depth survey of the wet technique is recommended.

  1. Assessment of Ports for Offshore Wind Development in the United States

    SciTech Connect (OSTI)

    Elkinton, Chris [DNV GL] [DNV GL; Blatiak, Alicia; Ameen, Hafsa

    2014-03-21T23:59:59.000Z

    As offshore wind energy develops in the United States, port facilities will become strategic hubs in the offshore wind farm supply chain because all plant and transport logistics must transit through these facilities. Therefore, these facilities must provide suitable infrastructure to meet the specific requirements of the offshore wind industry. As a result, it is crucial that federal and state policy-makers and port authorities take effective action to position ports in the offshore wind value chain to take best advantage of their economic potential. The U.S. Department of Energy tasked the independent consultancy GL Garrad Hassan (GL GH) with carrying out a review of the current capability of U.S. ports to support offshore wind project development and an assessment of the challenges and opportunities related to upgrading this capability to support the growth of as many as 54 gigawatts of offshore wind installed in U.S. waters by 2030. The GL GH report and the open-access web-based Ports Assessment Tool resulting from this study will aid decision-makers in making informed decisions regarding the choice of ports for specific offshore projects, and the types of investments that would be required to make individual port facilities suitable to serve offshore wind manufacturing, installation and/or operations. The offshore wind industry in the United States is still in its infancy and this study finds that additional port facilities capable of supporting offshore wind projects are needed to meet the anticipated project build-out by 2030; however, no significant barriers exist to prevent the development of such facilities. Furthermore, significant port capabilities are in place today with purpose-build port infrastructure currently being built. While there are currently no offshore wind farms operating in the United States, much of the infrastructure critical to the success of such projects does exist, albeit in the service of other industries. This conclusion is based on GL GH’s review of U.S. ports infrastructure and its readiness to support the development of proposed offshore wind projects in U.S. waters. Specific examples of facility costs and benefits are provided for five coastal regions (North Atlantic, South Atlantic, Gulf of Mexico, Great Lakes, and Pacific) around the country. GL GH began this study by identifying the logistical requirements of offshore wind ports to service offshore wind. This review was based on lessons learned through industry practice in Northern Europe. A web-based port readiness assessment tool was developed to allow a capability gap analysis to be conducted on existing port facilities based on the identified requirements. Cost models were added to the assessment tool, which allowed GL GH to estimate the total upgrade cost to a port over the period 2014-2030 based on a set of regional project build-out scenarios. Port fee information was gathered from each port allowing an estimate of the potential revenue to the port under this same set of scenarios. The comparison of these revenue and improvement cost figures provides an initial indication of the level of offshore wind port readiness. To facilitate a more in-depth infrastructure analysis, six ports from different geographic regions, with varied levels of interest and preparedness towards offshore wind, were evaluated by modeling a range of installation strategies and port use types to identify gaps in capability and potential opportunities for economic development. Commonalities, trends, and specific examples from these case studies are presented and provide a summary of the current state of offshore wind port readiness in the U.S. and also illustrate the direction some ports have chosen to take to prepare for offshore wind projects. For example, the land area required for wind turbine and foundation manufacturing is substantial, particularly due to the large size of offshore wind components. Also, the necessary bearing capacities of the quayside and storage area are typically greater for offshore wind components than for more conventiona

  2. E-Print Network 3.0 - ascites-a district general Sample Search...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Final report Summary: 1 Danish Energy Authority Final report Kaliningrad Regional District Heating Network 2004 - 2006... 2006 12;Kaliningrad District Heating Network Project 2004...

  3. E-Print Network 3.0 - aarhus police district Sample Search Results

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    dis- Summary: developed by LOGSTOR, Danfoss Redan and DTU will provide district heating to 12 new townhouses in Aarhus... . District heating will remain eco- nomically...

  4. San Joaquin Valley Unified Air Pollution Control District

    E-Print Network [OSTI]

    #12;San Joaquin Valley Unified Air Pollution Control District Best Available Control Technology.4.2 #12;San Joaquin Valley Air Pollution Control Distri RECEIVED ~ 2 ED ECEIVED www.valleyalr.org SJVAPCD-2370·(661)326-6900"FAX(661)326-6985 #12;San Joaquin Valley Unified Air Pollution Control District TITLE V MODIFICATION

  5. Livelihood Assets Atlas Mountainous Districts of NWFP (Pakistan)

    E-Print Network [OSTI]

    Richner, Heinz

    Livelihood Assets Atlas Mountainous Districts of NWFP (Pakistan) April 2009 SDPISustainable Mountainous Districts of NWFP (Pakistan) Abid Qaiyum Suleri, Babar Shahbaz, Sahab Haq Rana Nazir Mehmood and Gulbaz Ali Khan Sustainable Development Policy Institute 20 Hill Road, F-6/3, Islamabad - Pakistan www

  6. Peaks of Otter Soil and Water Conservation District

    E-Print Network [OSTI]

    Liskiewicz, Maciej

    leadership and education to sustain and utilize Bedford's natural resources in a manner that will enhancePeaks of Otter Soil and Water Conservation District Annual Report FY 2014 1071ATurnpikeRd.Bedford,VA24523 "The Peaks of Otter Soil and Water Con- servation District, with its partners, will provide

  7. California Energy Commission "Our District now has a heightened

    E-Print Network [OSTI]

    Program provided an energy audit that identified ways to improve the HVAC controls and further cut annualLOW INTEREST RATE LOANS AVAILABLE NOW! California Energy Commission "Our District now has a heightened awareness of energy savings and related cost savings." Steve Jorgensen District Superintendent

  8. QER- Comment of Lake Charles Harbor & Terminal District

    Broader source: Energy.gov [DOE]

    Good Afternoon, Please find the Lake Charles Harbor and Terminal District’s comments on Infrastructure Constraints in re: the QER Investigation hearing scheduled for Bismarck, ND on August 8, 2014. Please include these comments in the public record of the hearing. Thank you.

  9. Introduction THE YERINGTON DISTRICT, Nevada, contains porphyry Cu(Mo),

    E-Print Network [OSTI]

    Barton, Mark D.

    55 Introduction THE YERINGTON DISTRICT, Nevada, contains porphyry Cu(Mo), Cu skarn, Fe oxide with the Jurassic Yerington batholith, which serves as either host rock or as source for heat and ma- terials of the Yerington Porphyry Copper District: Magmatic to Nonmagmatic Sources of Hydrothermal Fluids, Their Flow Paths

  10. Judicial District Attorney's Office in conjunction with Community Partners

    E-Print Network [OSTI]

    fraud prevention, intervention, and victim support. 1st Judicial District - District Attorney Fraud Line, mail theft, dumpster diving and e-mail "phishing." 2. It's a good idea to carry your Social Security member, a financial advisor, or someone with your Power of Attorney who is paying your bills and managing

  11. Wrought iron hand tools in Port Royal, Jamaica: a study based upon a collection of the tools recovered from archaeological excavations and on tools listed in the probate inventories of colonial Port Royal, c. 1692

    E-Print Network [OSTI]

    Franklin, Marianne

    1992-01-01T23:59:59.000Z

    WROUGHT IRON HAND TOOLS IN PORT ROYAL, JAMAICA: A STUDY BASED UPON A COLLECTION OF THE TOOLS RECOVERED FROM ARCHAEOLOGICAL EXCAVATIONS AND ON TOOLS LISTED IN THE PROBATE INVENTORIES OF COLONIAL PORT ROYAL, c. 1692 A Thesis by MARIANNE... BASED UPON A COLLECTION OF THE TOOLS RECOVERED FROM ARCHAEOLOGICAL EXCAVATIONS AND ON TOOLS LISTED IN THE PROBATE INVENTORIES OF COLONIAL PORT ROYAL, c. 1692 A Thesis by MARIANNE FRANKLIN Approved as to style and content by: nny L. Hamilton...

  12. Mechanical code comparator

    DOE Patents [OSTI]

    Peter, Frank J. (Albuquerque, NM); Dalton, Larry J. (Bernalillo, NM); Plummer, David W. (Albuquerque, NM)

    2002-01-01T23:59:59.000Z

    A new class of mechanical code comparators is described which have broad potential for application in safety, surety, and security applications. These devices can be implemented as micro-scale electromechanical systems that isolate a secure or otherwise controlled device until an access code is entered. This access code is converted into a series of mechanical inputs to the mechanical code comparator, which compares the access code to a pre-input combination, entered previously into the mechanical code comparator by an operator at the system security control point. These devices provide extremely high levels of robust security. Being totally mechanical in operation, an access control system properly based on such devices cannot be circumvented by software attack alone.

  13. Banner Index Codes The Index code is a data-entry shortcut for the Fund code, Org code, and Program code in Banner

    E-Print Network [OSTI]

    Banner Index Codes The Index code is a data-entry shortcut for the Fund code, Org code, and Program code in Banner Finance (FO-P's). Implementation of the Index has greatly decreased data entry coding ­ Account (object) - Program (FOAP) code numbers on any of your accounting forms (Contracts, Purchase Orders

  14. Sandia National Laboratories: Codes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Codes Solar Thermochemical Hydrogen Production On June 13, 2014, in SNL maintains the equipment, experts, and partnerships required to develop technology for solar thermochemical...

  15. Tokamak Systems Code

    SciTech Connect (OSTI)

    Reid, R.L.; Barrett, R.J.; Brown, T.G.; Gorker, G.E.; Hooper, R.J.; Kalsi, S.S.; Metzler, D.H.; Peng, Y.K.M.; Roth, K.E.; Spampinato, P.T.

    1985-03-01T23:59:59.000Z

    The FEDC Tokamak Systems Code calculates tokamak performance, cost, and configuration as a function of plasma engineering parameters. This version of the code models experimental tokamaks. It does not currently consider tokamak configurations that generate electrical power or incorporate breeding blankets. The code has a modular (or subroutine) structure to allow independent modeling for each major tokamak component or system. A primary benefit of modularization is that a component module may be updated without disturbing the remainder of the systems code as long as the imput to or output from the module remains unchanged.

  16. Graph Concatenation for Quantum Codes

    E-Print Network [OSTI]

    Salman Beigi; Isaac Chuang; Markus Grassl; Peter Shor; Bei Zeng

    2010-02-03T23:59:59.000Z

    Graphs are closely related to quantum error-correcting codes: every stabilizer code is locally equivalent to a graph code, and every codeword stabilized code can be described by a graph and a classical code. For the construction of good quantum codes of relatively large block length, concatenated quantum codes and their generalizations play an important role. We develop a systematic method for constructing concatenated quantum codes based on "graph concatenation", where graphs representing the inner and outer codes are concatenated via a simple graph operation called "generalized local complementation." Our method applies to both binary and non-binary concatenated quantum codes as well as their generalizations.

  17. DECONTAMINATION OF DREDGED MATERIAL FROM THE PORT OF NEW YORK AND NEW JERSEY.

    SciTech Connect (OSTI)

    JONES,K.W.; STERN,E.A.; DONATO,K.R.; CLESCERI,N.L.

    1999-06-01T23:59:59.000Z

    The Port of New York and New Jersey ranks first in the United States in volume of petroleum products handled each year. In addition, many refineries are in operation on the New Jersey side of the Port. These activities have led to the discharge of significant amounts of petroleum hydrocarbons into the waters of the New York/New Jersey region. Intense industrial and commercial activities have also brought about major inputs of other organic and inorganic contaminants as would be expected in an industrialized, heavily populated urban port. Sediments that then are contaminated are a major problem for the region since they can no longer be disposed of by the traditional method of ocean disposal following the dredging operations required for the efficient operation of the Port. Decontamination and beneficial reuse of the dredged materials is one component of a comprehensive dredged material management plan being developed by the US Army Corps of Engineers. A demonstration decontamination project extending from bench- to field-scale operations is now in progress in the Port, and its current status and relevance for other regions is summarized.

  18. DECONTAMINATION OF DREDGED MATERIAL FROM THE PORT OF NEW YORK AND NEW JERSEY

    SciTech Connect (OSTI)

    JONES,K.W.; STERN,E.A.; DONATO,K.R.; CLESCERI,N.L.

    1999-06-01T23:59:59.000Z

    The Port of New York and New Jersey ranks first in the US in volume of petroleum products handled each year. In addition, many refineries are in operation on the New Jersey side of the Port. These activities have led to the discharge of significant amounts of petroleum hydrocarbons into the waters of the New York/New Jersey region. Intense industrial and commercial activities have also brought about major inputs of other organic and inorganic contaminants as would be expected in an industrialized, heavily populated urban port. Sediments that then are contaminated are a major problem for the region since they can no longer be disposed of by the traditional method of ocean disposal following the dredging operations required for the efficient operation of the Port. Decontamination and beneficial reuse of the dredged materials is one component of a comprehensive dredged material management plan being developed by the US Army Corps of Engineers. A demonstration decontamination project extending from bench- to field-scale operations is now in progress in the Port, and its current status and relevance for other regions is summarized.

  19. Qatargas exporting LNG from Qatar`s new Ras Laffan Port

    SciTech Connect (OSTI)

    NONE

    1997-02-24T23:59:59.000Z

    When the 135,000 cu m LNG carrier Al Zubarah departed Ras Laffan Port in December, Qatar entered a new era of commerce that will both boost the emirate`s economic development and influence energy trade around the world. The event capped more than a decade of planning, design, and construction of Ras Laffan Port--the world`s newest and largest LNG exporting facility. During the 1980s, the focus in Qatar was on exploration and development of North field, which holds the world`s largest reserves of nonassociated natural gas. In the 1990s, efforts concentrated on establishing a direct production and export link between North field, the new multi-billion-dollar Qatar Liquefied Gas Co. (Qatargas) gas liquefaction plant at Ras Laffan, and LNG export facilities at the 8.5 sq km Ras Laffan Port. Markets of the Far East will be first to be served by LNG from Ras Laffan Port. Two 25-year LNG supply contracts have been signed with buyers in Japan and South Korea, and negotiations are under way with potential customers from China, Taiwan, and Thailand. The paper describes the port, its operations, and export projects.

  20. Oil and gas field code master list 1994

    SciTech Connect (OSTI)

    Not Available

    1995-01-01T23:59:59.000Z

    This is the thirteenth annual edition of the Energy Information Administration`s (EIA) Oil and Gas Field Code Master List. It reflects data collected through October 1994 and provides standardized field name spellings and codes for all identified oil and/or gas fields in the United States. The master field name spellings and codes are to be used by respondents when filing the following Department of Energy (DOE) forms: Form EIA-23, {open_quotes}Annual Survey of Domestic Oil and Gas Reserves,{close_quotes} filed by oil and gas well operators (field codes are required from larger operators only); Forms FERC 8 and EIA-191, {open_quotes}Underground Gas Storage Report,{close_quotes} filed by natural gas producers and distributors who operate underground natural gas storage facilities. Other Federal and State government agencies, as well as industry, use the EIA Oil and Gas Field Code Master List as the standard for field identification. A machine-readable version of the Oil and Gas Field Code Master List is available from the National Technical Information Service, 5285 Port Royal Road, Springfield, Virginia 22161, (703) 487-4650. In order for the Master List to be useful, it must be accurate and remain current. To accomplish this, EIA constantly reviews and revises this list. The EIA welcomes all comments, corrections, and additions to the Master List. All such information should be given to the EIA Field Code Coordinator at (214) 953-1858. EIA gratefully acknowledges the assistance provides by numerous State organizations and trade associations in verifying the existence of fields and their official nomenclature.

  1. The study of an optimum method for inlet port performance in a D.I. diesel engine

    SciTech Connect (OSTI)

    Qi, G.; Zhou, J.; Liu, Z.; Chen, J. [Dalian Univ. of Technology (China)

    1995-12-31T23:59:59.000Z

    A new concept of synthetic performance coefficient of inlet port in D.I. diesel engines has been proposed from a viewpoint of efficiency of energy conversion in this paper. It makes the performance of various kinds of inlet ports in D.I. diesel engines compared with each other. Based on the regression analysis of the experimental results, it is found that the synthetic performance coefficient of inlet port has a close linear relation to the engine performance, and it can be used as a criterion to optimize the design of inlet port in D.I. diesel engines.

  2. Expansion of Urban Area in Irrigation Districts of the Rio Grande River Basin, 1996 - 2006: A Map Series 

    E-Print Network [OSTI]

    Leigh, Eric; Barroso, M.; Fipps, G.

    2009-01-01T23:59:59.000Z

    ?County?Water?Control?&?Improvement?District?No.1? Maverick? Presidio?County?Water?Improvement?District?No.1? Presidio? Santa?Cruz?Irrigation?District?No.15? Santa?Cruz? Santa?Maria?Irrigation?District?Cameron?County?No.4? Santa?Maria? United?Irrigation?District?of?Hidalgo?County? United? Valley...?County?Water?Control?&?Improvement?District?No.1? 134,900? Presidio?County?Water?Improvement?District?No.1? 2,780? Santa?Cruz?Irrigation?District?No.15? 75,080? Santa?Maria?Irrigation?District?Cameron?County?No.4? 10,183? United?Irrigation?District?of?Hidalgo?County? 57,374? Valley...

  3. Expansion of Urban Area in Irrigation Districts of the Rio Grande River Basin, 1996 - 2006: A Map Series

    E-Print Network [OSTI]

    Leigh, Eric; Barroso, M.; Fipps, G.

    ?County?Water?Control?&?Improvement?District?No.1? Maverick? Presidio?County?Water?Improvement?District?No.1? Presidio? Santa?Cruz?Irrigation?District?No.15? Santa?Cruz? Santa?Maria?Irrigation?District?Cameron?County?No.4? Santa?Maria? United?Irrigation?District?of?Hidalgo?County? United? Valley...?County?Water?Control?&?Improvement?District?No.1? 134,900? Presidio?County?Water?Improvement?District?No.1? 2,780? Santa?Cruz?Irrigation?District?No.15? 75,080? Santa?Maria?Irrigation?District?Cameron?County?No.4? 10,183? United?Irrigation?District?of?Hidalgo?County? 57,374? Valley...

  4. Reed-Muller Codes: Spherically-Punctured Codes and Decoding Algorithms

    E-Print Network [OSTI]

    Kapralova, Olga

    2013-01-01T23:59:59.000Z

    Linear codes . . . . . . . . . . . . . . . . . . . . . . .3.3 Code parameters . . . . . . . . . . . . . .of linear codes . . . . . . . . . . . . 1.5 Reed-Muller

  5. Actions Speak Louder than Words: A Case Study of a School District's Commitment to Equity

    E-Print Network [OSTI]

    Warren, Rachelle LeAnn

    2014-07-31T23:59:59.000Z

    What happens when a school district commits to equity? The focus on the school district is driven by the use of a framework that defined the school district as an institutional actor in reform efforts. Accordingly, the school district plays a...

  6. The Importance of a Small Rural School District to the Community

    E-Print Network [OSTI]

    Reynolds, Richard

    2013-01-07T23:59:59.000Z

    the sustainability issues associated with this school district and its importance to the community. Key stakeholders in the community and school district were interviewed to help develop a thick description of this district’s position in the community. Surveys were...

  7. Monovalve with integrated fuel injector and port control valve, and engine using same

    DOE Patents [OSTI]

    Milam, David M. (Metamora, IL)

    2001-11-06T23:59:59.000Z

    An engine includes an engine casing that defines a hollow piston cavity separated from an exhaust passage and an intake passage by a valve seat. A gas exchange valve member is positioned adjacent the valve seat and is moveable between an open position and a closed position. The gas exchange valve member also defines an opening that opens into the hollow piston cavity. A needle valve member is positioned in the gas exchange valve member adjacent a nozzle outlet and is moveable between an inject position and a blocked position. A port control valve member, which has a hydraulic surface, is mounted around the gas exchange valve member and moveable between an intake position and an exhaust position. A pilot valve is moveable between a first position at which the port control hydraulic surface is exposed to a source of high pressure fluid, and a second position at which the port control hydraulic surface is exposed to a source of low pressure fluid.

  8. Universal space-time codes from demultiplexed trellis codes

    E-Print Network [OSTI]

    Kose, Cenk; Wesel, R D

    2006-01-01T23:59:59.000Z

    and A. R. Calderbank, “Space-time codes for high data ratePerformance criteria and code construction,” IEEE Trans.of space–time trellis codes,” IEEE Trans. Commun. , vol. 51,

  9. Relation Between Surface Codes and Hypermap-Homology Quantum Codes

    E-Print Network [OSTI]

    Pradeep Sarvepalli

    2014-03-14T23:59:59.000Z

    Recently, a new class of quantum codes based on hypermaps were proposed. These codes are obtained from embeddings of hypergraphs as opposed to surface codes which are obtained from the embeddings of graphs. It is natural to compare these two classes of codes and their relation to each other. In this context two related questions are addressed in this paper: Can the parameters of hypermap-homology codes be superior to those of surface codes and what is precisely the relation between these two classes of quantum codes? We show that a canonical hypermap code is identical to a surface code while a noncanonical hypermap code can be transformed to a surface code by CNOT gates alone. Our approach is constructive; we construct the related surface code and the transformation involving CNOT gates.

  10. Electromagnetic Analysis For The Design Of ITER Diagnostic Port Plugs During Plasma Disruptions

    SciTech Connect (OSTI)

    Zhai, Y

    2014-03-03T23:59:59.000Z

    ITER diagnostic port plugs perform many functions including structural support of diagnostic systems under high electromagnetic loads while allowing for diagnostic access to plasma. The design of diagnotic equatorial port plugs (EPP) are largely driven by electromagnetic loads and associate response of EPP structure during plasma disruptions and VDEs. This paper summarizes results of transient electromagnetic analysis using Opera 3d in support of the design activities for ITER diagnostic EPP. A complete distribution of disruption loads on the Diagnostic First Walls (DFWs). Diagnostic Shield Modules (DSMs) and the EPP structure, as well as impact on the system design integration due to electrical contact among various EPP structural components are discussed.

  11. A frictional model of a two-port unbounded ocean basin

    E-Print Network [OSTI]

    Wert, Richard Thomas

    1968-01-01T23:59:59.000Z

    A FRICTIONAL MODEL OF A TWO-PORT UNBOUNDED OCEAN BASIN A Thesis by RICHARD T. WERT Submitted to the Graduate College of the Texas AE M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE May 1968 Major... Subject: Physical Oceanography A FRICTIONAL MODEL OF A TWO-PORT UNBOUNDED OCEAN BASIN A Thesis by RICHARD T. WERT Approved as to style and content by: (Chairxnan of Coxnxnittee) (Head of the Departxnent) (M her) (Mexnber) May 1968 A Frictional...

  12. Report number codes

    SciTech Connect (OSTI)

    Nelson, R.N. (ed.)

    1985-05-01T23:59:59.000Z

    This publication lists all report number codes processed by the Office of Scientific and Technical Information. The report codes are substantially based on the American National Standards Institute, Standard Technical Report Number (STRN)-Format and Creation Z39.23-1983. The Standard Technical Report Number (STRN) provides one of the primary methods of identifying a specific technical report. The STRN consists of two parts: The report code and the sequential number. The report code identifies the issuing organization, a specific program, or a type of document. The sequential number, which is assigned in sequence by each report issuing entity, is not included in this publication. Part I of this compilation is alphabetized by report codes followed by issuing installations. Part II lists the issuing organization followed by the assigned report code(s). In both Parts I and II, the names of issuing organizations appear for the most part in the form used at the time the reports were issued. However, for some of the more prolific installations which have had name changes, all entries have been merged under the current name.

  13. Empire District Electric- Low Income New Homes Program

    Broader source: Energy.gov [DOE]

    Empire District Electric offers rebates for the utilization of energy efficient measures and appliances in new, low-income homes. Rebates are available for several types of building insulation,...

  14. Qualifying RPS State Export Markets (District of Columbia)

    Broader source: Energy.gov [DOE]

    This entry lists the states with Renewable Portfolio Standard (RPS) policies that accept generation located in District of Columbia as eligible sources towards their RPS targets or goals. For...

  15. U.S. geothermal district heating : barriers and enablers

    E-Print Network [OSTI]

    Thorsteinsson, Hildigunnur H

    2008-01-01T23:59:59.000Z

    Geothermal district heating experience in the U.S. is reviewed and evaluated to explore the potential impact of utilizing this frequently undervalued renewable energy resource for space and hot water heating. Although the ...

  16. EA-0923: Winnett School District Boiler Replacement Project, Winnett, Montana

    Broader source: Energy.gov [DOE]

    This EA evaluates the environmental impacts of the proposal to replace the Winnett School District complex's existing oil-fired heating system with a new coal-fired heating system with funds...

  17. Financing Energy Upgrades for K-12 School Districts

    Broader source: Energy.gov [DOE]

    U.S. Department of Energy (DOE) Technical Assistance Program (TAP) presentation at a TAP webinar held on April 11, 2013 and dealing with how to finance energy efficiency upgrades for K-12 school districts.

  18. Boulder Valley School District (Colorado) Power Purchase Agreement...

    Broader source: Energy.gov (indexed) [DOE]

    Boulder Valley School District completed a power purchase agreement to install 1.4 MW of solar PV that are expected to reduce electricity bills in 14 schools by about 10% over the...

  19. NEZ PERCE SOIL AND WATER CONSERVATION DISTRICT CULDESAC, IDAHO 83524

    E-Print Network [OSTI]

    of Culdesac, McGregor Company, and the Idaho Soil Conservation Commission. In addition, the District has of the wetland and sod bio-logs that are installed our projects. This results in more on-the-ground projects

  20. A Geothermal District-Heating System and Alternative Energy Research...

    Open Energy Info (EERE)

    District-Heating System and Alternative Energy Research Park on the NM Tech Campus Geothermal Project Jump to: navigation, search Last modified on July 22, 2011. Project Title A...

  1. November 20, 2012 Webinar: District Heating with Renewable Energy

    Office of Energy Efficiency and Renewable Energy (EERE)

    This webinar was held November 20, 2012, and provided information on Indiana's Ball State University geothermal heat pump system, and a hot-water district heating system in St. Paul, Minnesota....

  2. Empire District Electric- Commercial and Industrial Energy Efficiency Rebates

    Broader source: Energy.gov [DOE]

    The Empire District Electric Company offers a Commercial/Industrial Prescriptive Rebate Program to its non-residential customers in Arkansas who purchase certain high-efficiency equipment for...

  3. An Integrated Pest Management survey of Texas school districts

    E-Print Network [OSTI]

    Shodrock, Damon Leon

    1994-01-01T23:59:59.000Z

    Texas school district personnel were surveyed using a mailed questionnaire to determine the status of Integrated Pest Management (IPM) programs and the efficacy of conventional pest control practices. Of the 517 survey participants, 12.4% had...

  4. The role of the district office in instructional practice reform

    E-Print Network [OSTI]

    Rizzi, Karen Schultz

    2008-01-01T23:59:59.000Z

    to 8,113 students. In 2005-06, 7,436 of the 8,113 studentsinterview, June 2007) In 2005-06, the district office hiredEvaluation forms, Schmoker, 2005-06). Nevertheless, a few

  5. army engineer district: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Prepared for the U.S. Army Corps of Engineers, Portland District, Environmental Management and Restoration Websites Summary: PNNL-22788 Final Prepared for the U.S. Army Corps...

  6. army engineers district: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Prepared for the U.S. Army Corps of Engineers, Portland District, Environmental Management and Restoration Websites Summary: PNNL-22788 Final Prepared for the U.S. Army Corps...

  7. 11.422 Business Improvement Districts, Spring 2003

    E-Print Network [OSTI]

    Hoyt, Lorlene M.

    Focuses on the role of the business improvement district (BID) as a popular and contemporary tool for urban revitalization. Explores BID origins, theoretical underpinnings, enabling legislation, and organizational issues. ...

  8. Power Districts: Acquisition of Right-of-Way (Nebraska)

    Broader source: Energy.gov [DOE]

    This statute describes procedures for power districts (utilities, corporations, or municipalities that engage in the generation or transmission of electricity) to obtain a right-of-way for the...

  9. Southern Power District- Residential Energy Efficiency Rebate Programs

    Broader source: Energy.gov [DOE]

    Southern Power District (SPD) offers rebates for the purchase and installation of efficient air source heat pumps, geothermal heat pumps, attic insulation, and HVAC tune-ups. Contractors who...

  10. Nebraska Public Power District- Residential Energy Efficiency Rebate Programs

    Broader source: Energy.gov [DOE]

    The Nebraska Public Power District offers rebates to homeowners who purchase energy efficient heat pumps, upgrade their insulation, and/or have their cooling system tuned-up. The High Efficiency...

  11. Motion to Intervene and Comments of Public Utility District No...

    Broader source: Energy.gov (indexed) [DOE]

    A motion to intervene and comments from Public Utility District No. 1 (Pend Oreille County, Washington) on PP 99-1 Notice of Intent to Amend Presidential Permit, where DOE proposes...

  12. Thermodynamic Analysis of Combined Cycle District Heating System

    E-Print Network [OSTI]

    Suresh, S.; Gopalakrishnan, H.; Kosanovic, D.

    2011-01-01T23:59:59.000Z

    This paper presents a thermodynamic analysis of the University of Massachusetts' Combined Heat and Power (CHP) District Heating System. Energy and exergy analyses are performed based on the first and second laws of thermodynamics for power...

  13. Local Power Empowers: CHP and District Energy (Text Version)...

    Broader source: Energy.gov (indexed) [DOE]

    assistance program overview then we're gonna define CHPs. We're also gonna define district cooling and heating. We're then going to look at some of the technologies...

  14. Property Assessed Clean Energy Financing (District of Columbia)

    Broader source: Energy.gov [DOE]

    The District of Columbia offers a commercial Property Assessed Clean Energy (PACE) program. In order to receive financing through the commercial PACE program, applicants must first have an energy...

  15. Lake Improvement District Law and County Lake Improvement Program (Minnesota)

    Broader source: Energy.gov [DOE]

    Lake Improvement Districts may be established by county boards in order to “improve the quality of water in lakes; provide for reasonable assurance of water quantity in lakes, where feasible and...

  16. Quantum stabilizer codes and beyond

    E-Print Network [OSTI]

    Pradeep Kiran Sarvepalli

    2008-10-14T23:59:59.000Z

    The importance of quantum error correction in paving the way to build a practical quantum computer is no longer in doubt. This dissertation makes a threefold contribution to the mathematical theory of quantum error-correcting codes. Firstly, it extends the framework of an important class of quantum codes -- nonbinary stabilizer codes. It clarifies the connections of stabilizer codes to classical codes over quadratic extension fields, provides many new constructions of quantum codes, and develops further the theory of optimal quantum codes and punctured quantum codes. Secondly, it contributes to the theory of operator quantum error correcting codes also called as subsystem codes. These codes are expected to have efficient error recovery schemes than stabilizer codes. This dissertation develops a framework for study and analysis of subsystem codes using character theoretic methods. In particular, this work establishes a close link between subsystem codes and classical codes showing that the subsystem codes can be constructed from arbitrary classical codes. Thirdly, it seeks to exploit the knowledge of noise to design efficient quantum codes and considers more realistic channels than the commonly studied depolarizing channel. It gives systematic constructions of asymmetric quantum stabilizer codes that exploit the asymmetry of errors in certain quantum channels.

  17. Rateless Codes for AVC Models

    E-Print Network [OSTI]

    Sarwate, A D; Gastpar, M

    2010-01-01T23:59:59.000Z

    2004. [7] M. Luby, “LT codes,” in Proc. 43rd Ann. IEEE Symp.8] A. Shokrollahi, “Fountain codes,” in Proc. 41st AllertonChannel capacities for list codes,” J. Appl. Probabil. ,

  18. Unequal Error Protection Turbo Codes

    E-Print Network [OSTI]

    Henkel, Werner

    Unequal Error Protection Turbo Codes Diploma Thesis Neele von Deetzen Arbeitsbereich Nachrichtentechnik School of Engineering and Science Bremen, February 28th, 2005 #12;Unequal Error Protection Turbo Convolutional Codes / Turbo Codes 18 3.1 Structure

  19. Oxford Area Community School District (Michigan) Bonds Case Study

    Broader source: Energy.gov [DOE]

    Michigan’s Oxford Area Community School District entered into an energy savings performance contract and issued limited tax general obligation bonds to fund the up-front costs of almost $3 million of energy-related improvements. Case study is excerpted from Financing Energy Upgrades for K-12 School Districts: A Guide to Tapping into Funding for Energy Efficiency and Renewable Energy Improvements. Author: Merrian Borgeson and Mark Zimring

  20. Williamson County School District (Tennessee) Bonds Case Study

    Broader source: Energy.gov [DOE]

    Williamson County School District entered into an energy savings performance contract with an energy services company and completed a $5.7 million lease-purchase agreement to fund a range of energy-related improvements across 27 school facilities. Case study is excerpted from Financing Energy Upgrades for K-12 School Districts: A Guide to Tapping into Funding for Energy Efficiency and Renewable Energy Improvements. Author: Merrian Borgeson and Mark Zimring

  1. Buying, Selling and Exporting Groundwater: Implications for Groundwater Conservation Districts

    E-Print Network [OSTI]

    Kaiser, Ronald; Lesikar, Bruce A.; Silvey, Valeen

    given at the Groundwater Conservation District Seminar Series on May 28, 2003, at the Texas A&M University George Bush Presidential Conference Center. Summaries of the following presentations are presented in this report: The Status of Groundwater Sales... in a Sales/ Lease Agreement, by Sandra Burns. Regulation of Exportation of Underground Water, by Doug Caroom. Roberts County Transportation Permits, by C.E. Williams. Export Fees: A Groundwater District Limits and Uses, by Jace Houston. The report also...

  2. 1992 National census for district heating, cooling and cogeneration

    SciTech Connect (OSTI)

    Not Available

    1993-07-01T23:59:59.000Z

    District energy systems are a major part of the energy use and delivery infrastructure of the United States. With nearly 6,000 operating systems currently in place, district energy represents approximately 800 billion BTU per hour of installed thermal production capacity, and provides over 1.1 quadrillion BTU of energy annually -- about 1.3% of all energy used in the US each year. Delivered through more that 20,000 miles of pipe, this energy is used to heat and cool almost 12 billion square feet of enclosed space in buildings that serve a diverse range of office, education, health care, military, industrial and residential needs. This Census is intended to provide a better understanding of the character and extent of district heating, cooling and cogeneration in the United States. It defines a district energy system as: Any system that provides thermal energy (steam, hot water, or chilled water) for space heating, space cooling, or process uses from a central plant, and that distributes the energy to two or more buildings through a network of pipes. If electricity is produced, the system is a cogenerating facility. The Census was conducted through surveys administered to the memberships of eleven national associations and agencies that collectively represent the great majority of the nation`s district energy system operators. Responses received from these surveys account for about 11% of all district systems in the United States. Data in this report is organized and presented within six user sectors selected to illustrate the significance of district energy in institutional, community and utility settings. Projections estimate the full extent of district energy systems in each sector.

  3. Douglas County School District (Nevada) Bonds Case Study

    Broader source: Energy.gov [DOE]

    Douglas County School District faced a challenging combination of aging equipment and buildings (most over 37 years old), rising energy costs, and limited access to taxpayer funds due to the fiscally-conservative makeup of the region’s voters.. Case study is excerpted from Financing Energy Upgrades for K-12 School Districts: A Guide to Tapping into Funding for Energy Efficiency and Renewable Energy Improvements. Author: Merrian Borgeson and Mark Zimring

  4. Simulation of Eye-Diagrams on Lossy Transmission Lines using Extracted Data from 1-port TDR Measurements

    E-Print Network [OSTI]

    Swaminathan, Madhavan

    Simulation of Eye-Diagrams on Lossy Transmission Lines using Extracted Data from 1-port TDR of transmission lines were measured from 1- port TDR measurements. Using the extracted data, eye- diagrams of lossy transmission lines were simulated based on a non-physical RLGC model. Conventional W element

  5. Lasers in Surgery and Medicine 39:118127 (2007) Laser Surgery of Port Wine Stains Using Local Vaccum

    E-Print Network [OSTI]

    Aguilar, Guillermo

    Lasers in Surgery and Medicine 39:118­127 (2007) Laser Surgery of Port Wine Stains Using Local Vaccum Pressure: Changes in Calculated Energy Deposition (Part II) Walfre Franco, PhD,1,2 * Michael port wine stain (PWS) laser treatment. Study Design/ Materials and Methods: Mathematical models

  6. Quantum Error Correcting Subsystem Codes From Two Classical Linear Codes

    E-Print Network [OSTI]

    Dave Bacon; Andrea Casaccino

    2006-10-17T23:59:59.000Z

    The essential insight of quantum error correction was that quantum information can be protected by suitably encoding this quantum information across multiple independently erred quantum systems. Recently it was realized that, since the most general method for encoding quantum information is to encode it into a subsystem, there exists a novel form of quantum error correction beyond the traditional quantum error correcting subspace codes. These new quantum error correcting subsystem codes differ from subspace codes in that their quantum correcting routines can be considerably simpler than related subspace codes. Here we present a class of quantum error correcting subsystem codes constructed from two classical linear codes. These codes are the subsystem versions of the quantum error correcting subspace codes which are generalizations of Shor's original quantum error correcting subspace codes. For every Shor-type code, the codes we present give a considerable savings in the number of stabilizer measurements needed in their error recovery routines.

  7. An Overview of Operational Characteristics of Selected Irrigation Districts in the Texas Lower Rio Grande Valley: Hidalgo County Irrigation District No. 2 (San Juan)

    E-Print Network [OSTI]

    Stubbs, Megan J.; Rister, M. Edward; Sturdivant, Allen W.; Lacewell, Ronald D.

    to both urban communities and agriculture (which includes most of the irrigation districts in the Lower Rio Grande Valley) brings forth more questions related to how each of these systems operate. Individual or groupings of irrigation districts..., infrastructure, adoptive rate of technology, etc. can vary significantly across irrigation districts. So, to completely understand and appreciate the collective Lower Rio Grande Valley irrigation district system, one must understand the idiosyncrasies...

  8. No Code: Null Programs

    E-Print Network [OSTI]

    Montfort, Nick

    2014-06-05T23:59:59.000Z

    To continue the productive discussion of uninscribed artworks in Craig Dworkin’s No Medium, this report discusses, in detail, those computer programs that have no code, and are thus empty or null. Several specific examples ...

  9. Climate Code Foundation

    E-Print Network [OSTI]

    Barnes, Nick; Jones, David

    2011-07-05T23:59:59.000Z

    Climate Code Foundation - who are we? A non-profit organisation founded in August 2010; our goal is to promote the public understanding of climate science, by increasing the visibility and clarity of the software used in climate science...

  10. Building Energy Code

    Broader source: Energy.gov [DOE]

    Authority for adopting the state energy codes was previously vested in the Energy Security Office of the Department of Commerce (originally the Department of Public Services). In 1999-2000, the...

  11. Quantum error control codes

    E-Print Network [OSTI]

    Abdelhamid Awad Aly Ahmed, Sala

    2008-10-10T23:59:59.000Z

    QUANTUM ERROR CONTROL CODES A Dissertation by SALAH ABDELHAMID AWAD ALY AHMED Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY May 2008 Major... Subject: Computer Science QUANTUM ERROR CONTROL CODES A Dissertation by SALAH ABDELHAMID AWAD ALY AHMED Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of DOCTOR OF PHILOSOPHY...

  12. Geodatabase of the South Texas Uranium District

    E-Print Network [OSTI]

    Mark Beaman; William Wade Mcgee

    Uranium and its associated trace elements and radionuclides are ubiquitous in the South Texas Tertiary environment. Surface mining of this resource from the 1960s through the early 1980s at over sixty locations has left an extensive anthropological footprint (Fig. 1) in the lower Nueces and San Antonio river basins. Reclamation of mining initiated after 1975 has been under the regulatory authority of the Railroad Commission of Texas (RCT). However, mines that were active before the Texas Surface Mining Act of 1975 was enacted, and never reclaimed, are now considered abandoned. The Abandoned Mine Land Section of the RCT is currently reclaiming these pre-regulation uranium mines with funding from the federal government. The RCT monitors the overall effectiveness of this process through post-reclamation radiation and vegetative cover surveys, water quality testing, slope stability and erosion control monitoring. Presently a number of graduate and postgraduate students are completing research on the watershed and reservoir distribution of trace elements and radionuclides downstream of the South Texas Uranium District. The question remains as to whether the elevated levels of uranium, its associated trace elements and radiation levels in the South Texas environment are due to mining

  13. Tushino - 3 district heating project/Moscow

    SciTech Connect (OSTI)

    Mayer, H.W.

    1995-09-01T23:59:59.000Z

    The contract for supply and installation of Honeywell control equipment at the district heating plant in Moscow suburb of Tushino was signed between the Mayor of Moscow and Honeywell in December 1991. Total contract value is US$3 million. The aim is to demonstrate on a pilot project the potential energy savings and improved pleat safety which can be achieved by means of electronic control of latest design. The Honeywell contract basically covers modernization of instrumentation and control of the gas fired heating plant, comprising water preparation and 4 boilers, of 100 Gcal/h each, i.e., 400 Gcal/h total. The plant is feeding the hot water network which has 60 heat exchanger stations connected. The heat exchangers (thermal rating between 2 to 10 Gcal/h each) supply hot water mainly to residential building blocks for apartment heating and domestic hot water. Honeywell`s responsibility covers engineering, supply of TDC 3000 micro-processor based control system for the boilers and DeltaNet Excel control for the Heat Exchangers. The contract also includes installation and start-up of the total control system.

  14. Maintaining Access to America's Intermodal Ports/Technologies for Decontamination of Dredged

    E-Print Network [OSTI]

    Brookhaven National Laboratory

    Maintaining Access to America's Intermodal Ports/Technologies for Decontamination of Dredged will be the control and treatment of contaminated sediments dredged from our nation's waterways. More than 306 million cubic meters (m 3 ) (400 million cubic yards [cy]) of sediments are dredged annually from U.S. waterways

  15. BOCA RATON DANIA BEACH DAVIE FORT LAUDERDALE HARBOR BRANCH JUPITER PORT ST. LUCIE Educational Plant Survey

    E-Print Network [OSTI]

    Fernandez, Eduardo

    BOCA RATON DANIA BEACH DAVIE FORT LAUDERDALE HARBOR BRANCH JUPITER PORT ST. LUCIE Educational Plant Survey 2011/2012 ­ 2016/2017 Approved by FAU BOT on June 15, 2011 #12;EDUCATIONAL PLANT SURVEY Florida ...................................................................................................................... ii Educational Plant Survey Team

  16. Centrality and vulnerability in liner shipping networks: revisiting the Northeast Asian port hierarchy

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    . While the possible reasons explaining such imbalances are explored in more detail elsewhere [1], a brief and intermediacy were recognized as the two major facets behind the emergence of hub ports [7], while the concept seaports with inland logistics hubs, but also with offshore hubs, in a context of vertical integration

  17. Recent territorial changes in the port of La Plata, Buenos Aires. Argentina Prof. Lic. Fabricio Gliemmo

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Recent territorial changes in the port of La Plata, Buenos Aires. Argentina Prof. Lic. Fabricio Gliemmo Members of the TAG team. "Lugar Innov@" - UNLP Universidad Nacional de La Plata. Argentina Av.7 Nº 776 ­ 1900 La Plata, Argentina geo_fabricio@hotmail.com + (54) 221-4895394 ENTI Salerno 2009

  18. Boundary port Hamiltonian control of a class of nanotweezers Hector Ramirez and Yann Le Gorrec

    E-Print Network [OSTI]

    Boyer, Edmond

    and control of a class of nan- otweezers used for DNA-manipulation. The Nanotweezer may be modelled. A boundary controlled-port Hamiltonian model for the ensemble and an exponentially stabilizing controller for the modelling, control and simula- tion of a class of nanotweezers. Indeed, this framework is particularly

  19. Multi-port DC-DC Power Converter for Renewable Energy Application 

    E-Print Network [OSTI]

    Chou, Hung-Ming

    2010-01-16T23:59:59.000Z

    . . . . . . . . . . . . . 4 1. For Wind Power . . . . . . . . . . . . . . . . . . . . . 4 2. For Solar Photovoltaics . . . . . . . . . . . . . . . . . 6 3. For Fuel Cell . . . . . . . . . . . . . . . . . . . . . . . 7 4. On Energy Storage... . . . . . . . . . . . . . . . . . . . . 7 C. Concept of Hybrid Distributed Generation System . . . . . 8 D. Benefits of Multi-port Converter . . . . . . . . . . . . . . . 9 E. Previous Research Work . . . . . . . . . . . . . . . . . . . 12 F. Research Objective...

  20. Quel futur pour Huitzilac, municipio rural aux portes de Mexico. Entre contraintes urbaines et environnementales.

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    p. 1 Quel futur pour Huitzilac, municipio rural aux portes de Mexico. Entre contraintes urbaines et un municipio mexicain entre Mexico et Cuernavaca, dans l'Etat de Morelos. Très rural, ses principaux sur la chasse dite Ley Forestal y de Caza et sur le Plan Nacional de Desarrollo3 1983-88 pour la

  1. EULERIANLAGRANGIAN LOCALIZED ADJOINT METHODS FOR TRANS PORT OF NUCLEARWASTE CONTAMINATION IN POROUS MEDIA

    E-Print Network [OSTI]

    Ewing, Richard E.

    EULERIAN­LAGRANGIAN LOCALIZED ADJOINT METHODS FOR TRANS­ PORT OF NUCLEAR­WASTE CONTAMINATION­ creasingly threatened by organic, inorganic, and radioactive pollutants as well as high­level nuclear waste developed for use by the Nuclear Regulatory Commission to analyze deep geologic nuclear waste disposal

  2. Fusion Engineering and Design 43 (1998) 7592 The ITER port limiter design

    E-Print Network [OSTI]

    Raffray, A. René

    with those in the associated cooling water system. Installation in the ports allows the limiter position to be adjusted from outside the cryostat and greatly simplifies the remote handling tasks required coolant mass flow (cooling only where necessary). No access holes or large gaps due to the possi- bility

  3. Lessons Learned Using the Insertable Robotic Effector Platform (IREP) for Single Port Access Surgery

    E-Print Network [OSTI]

    Simaan, Nabil

    ]. Design requirements included the coverage of a workspace of at least 50 mm in each Cartesian directionLessons Learned Using the Insertable Robotic Effector Platform (IREP) for Single Port Access towards achieving this goal, our team has developed the Insertable Robotic Effector Platform (IREP

  4. Second Line of Defense, Megaports Initiative, Operational Testing and Evaluation Plan, Port of Lazaro Cardenas, Mexico

    SciTech Connect (OSTI)

    Hughes, Jamie D.

    2012-05-30T23:59:59.000Z

    The purpose of the Operational Testing and Evaluation (OT&E) phases of the project is to prepare for turnover of the Megaports System supplied by U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA)—located at the Export Lanes of the Port of Lazaro Cardenas, Mexico—to the Government of Mexico (GOM).

  5. Computer Control of a Syngas Complex at LaPorte, Texas

    E-Print Network [OSTI]

    Chatterjee, N.

    1981-01-01T23:59:59.000Z

    Air Products and Chemicals has successfully implemented a mini-computer monitoring and control system at its LaPorte Syngas Complex as an integral part of its energy management strategy. The production complex consists of two separate plants at La...

  6. Cost-efficient monitoring of water quality in district heating systems This article examines the monitoring strategy for water quality in a large Danish district

    E-Print Network [OSTI]

    Cost-efficient monitoring of water quality in district heating systems This article examines the monitoring strategy for water quality in a large Danish district heating system ­ and makes a proposal for a technical and economic improvement. Monitoring of water quality in district heating systems is necessary

  7. Alternatives to deep-draft port dredging for US coal export development: a preliminary assessment. [72 references

    SciTech Connect (OSTI)

    Bertram, K.M.

    1982-03-01T23:59:59.000Z

    This report compares deep-draft port dredging with alternative methods for increasing US coal export capacity. Five basic types of alternatives to port dredging are discussed: (1) coarse-coal pipelines, (2) coal slurry pipelines, (3) vessel-to-ship loading, (4) barge-carrying ships, and (5) extra-wide-beam coal ships. Because more than one approach is investigated for these alternatives, a total of 12 options are discussed. After describing the factors exerting growing pressure on the United States to improve its seaport coal-exporting capabilities, the current status of port dredging is presented. Funding, approval process, implementation time, and physical capability considerations are analyzed; significant uncertainties are found to exist about the financial and time requirements for port dredging. The 12 alternatives to port dredging are next described and compared on the basis of (1) financial considerations, (2) implementation-time requirements, and (3) environmental and technological constraints. At least two-thirds of the approximately 180 million tons of planned expansion by the year 2000 of coal-export capacity is based on the assumption of port dredging taking place. Therefore, it appears that port dredging alone could enable US ports to handle the coal export volumes projected for the year 2000. Dredging is also concluded to improve port efficiency and reduce general transportation costs the most. However, the uncertainties about the financing, the environmental concerns, and the time requirements for deep-draft dredging throw considerable doubt upon its viability as a single means of needed port capacity expansion. It is concluded that all of the alternatives except the barge-carrying-vessel systems would be good supplementary systems.

  8. Design of the Long-term Waste Management Facility for Historic LLRW Port Hope Project - 13322

    SciTech Connect (OSTI)

    Campbell, Don; Barton, David [Conestoga-Rovers and Associates, 651 Colby Drive, Waterloo, Ontario N2V 1C2 (Canada)] [Conestoga-Rovers and Associates, 651 Colby Drive, Waterloo, Ontario N2V 1C2 (Canada); Case, Glenn [Atomic Energy of Canada Limited, 115 Toronto Road, Port Hope, Ontario L1A 3S4 (Canada)] [Atomic Energy of Canada Limited, 115 Toronto Road, Port Hope, Ontario L1A 3S4 (Canada)

    2013-07-01T23:59:59.000Z

    The Municipality of Port Hope is located on the northern shores of Lake Ontario approximately 100 km east of Toronto, Ontario, Canada. Starting in the 1930's, radium and later uranium processing by Eldorado Gold Mines Limited (subsequently Eldorado Nuclear Limited) (Eldorado) at their refinery in Port Hope resulted in the generation of process residues and wastes that were disposed of indiscriminately throughout the Municipality until about the mid-1950's. These process residues contained radium (Ra- 226), uranium, arsenic and other contaminants. Between 1944 and 1988, Eldorado was a Federal Crown Corporation, and as such, the Canadian Federal Government has assumed responsibility for the clean-up and long-term management of the historic waste produced by Eldorado during this period. The Port Hope Project involves the construction and development of a new long-term waste management facility (LTWMF), and the remediation and transfer of the historic wastes located within the Municipality of Port Hope to the new LTWMF. The new LTWMF will consist of an engineered above-ground containment mound designed to contain and isolate the wastes from the surrounding environment for the next several hundred years. The design of the engineered containment mound consists of a primary and secondary composite base liner system and composite final cover system, made up of both natural materials (e.g., compacted clay, granular materials) and synthetic materials (e.g., geo-synthetic clay liner, geo-membrane, geo-textiles). The engineered containment mound will cover an area of approximately 13 hectares and will contain the estimated 1.2 million cubic metres of waste that will be generated from the remedial activities within Port Hope. The LTWMF will also include infrastructure and support facilities such as access roads, administrative offices, laboratory, equipment and personnel decontamination facilities, waste water treatment plant and other ancillary facilities. Preliminary construction activities for the Port Hope LTWMF commenced in 2012 and are scheduled to continue over the next few years. The first cell of the engineered containment mound is scheduled to be constructed in 2015 with waste placement into the Port Hope LTWMF anticipated over the following seven year period. (authors)

  9. Nested Quantum Error Correction Codes

    E-Print Network [OSTI]

    Zhuo Wang; Kai Sun; Hen Fan; Vlatko Vedral

    2009-09-28T23:59:59.000Z

    The theory of quantum error correction was established more than a decade ago as the primary tool for fighting decoherence in quantum information processing. Although great progress has already been made in this field, limited methods are available in constructing new quantum error correction codes from old codes. Here we exhibit a simple and general method to construct new quantum error correction codes by nesting certain quantum codes together. The problem of finding long quantum error correction codes is reduced to that of searching several short length quantum codes with certain properties. Our method works for all length and all distance codes, and is quite efficient to construct optimal or near optimal codes. Two main known methods in constructing new codes from old codes in quantum error-correction theory, the concatenating and pasting, can be understood in the framework of nested quantum error correction codes.

  10. Accumulate-Repeat-Accumulate Codes: Systematic Codes Achieving the Binary

    E-Print Network [OSTI]

    Sason, Igal

    Accumulate-Repeat-Accumulate Codes: Systematic Codes Achieving the Binary Erasure Channel Capacity@ee.technion.ac.il Abstract The paper introduces ensembles of accumulate-repeat-accumulate (ARA) codes which asymp- totically by the first capacity-achieving ensembles of ir- regular repeat-accumulate (IRA) codes with bounded complexity

  11. Code: A Lightweight and Flexible Mobile Code Toolkit

    E-Print Network [OSTI]

    Picco, Gian Pietro

    evaluation of mobile code technology does not exist yet, some studies already evidenced that the powerful of client­server and mobile code in reducing the network traffic generated by management. The theoretical¯Code: A Lightweight and Flexible Mobile Code Toolkit Gian Pietro Picco Dip. Automatica e

  12. Co-sponsored second quarter progress review conference on district heating

    SciTech Connect (OSTI)

    None

    1980-01-01T23:59:59.000Z

    A summary of the progress review conference on district heating and cooling systems is presented. The agenda and lists of speakers and attendees are presented. A history of district heating and some present needs and future policies are given and an excerpt from the National District Heating Program Strategy (DOE, March 1980) is included. Following the presentation, District Heating and Cooling Systems Program, by Alan M. Rubin, a fact sheet on DOE's Integrated Community Energy Systems Program and information from an oral presentation, District Heating and Cooling Systems for Communities Through Power Plant Retrofit Distribution Network, are given. The Second Quarterly Oral Report to the US DOE on the District Heating and Cooling Project in Detroit; the executive summary of the Piqua, Ohio District Heating and Cooling Demonstration Project; the Second Quarterly Report of the Moorehead, Minnesota District Heating Project; and the report from the Moorehead, Minnesota mayor on the Hot Water District Heating Project are presented.

  13. MHD Generation Code

    E-Print Network [OSTI]

    Frutos-Alfaro, Francisco

    2015-01-01T23:59:59.000Z

    A program to generate codes in Fortran and C of the full Magnetohydrodynamic equations is shown. The program used the free computer algebra system software REDUCE. This software has a package called EXCALC, which is an exterior calculus program. The advantage of this program is that it can be modified to include another complex metric or spacetime. The output of this program is modified by means of a LINUX script which creates a new REDUCE program to manipulate the MHD equations to obtain a code that can be used as a seed for a MHD code for numerical applications. As an example, we present part of output of our programs for Cartesian coordinates and how to do the discretization.

  14. Updated Users' Guide for RSAP -- A Code for Display and Manipulation of Neutron Cross Section Data and SAMMY Fit Results

    SciTech Connect (OSTI)

    Sayer, R.O.

    2003-07-29T23:59:59.000Z

    RSAP [1] is a computer code for display and manipulation of neutron cross section data and selected SAMMY output. SAMMY [2] is a multilevel R-matrix code for fitting neutron time-of-flight cross-section data using Bayes' method. This users' guide provides documentation for the recently updated RSAP code (version 6). The code has been ported to the Linux platform, and several new features have been added, including the capability to read cross section data from ASCII pointwise ENDF files as well as double-precision PLT output from SAMMY. A number of bugs have been found and corrected, and the input formats have been improved. Input items are parsed so that items may be separated by spaces or commas.

  15. Cyclic simplex coded OTDR SNR enhancement of coded optical time domain reflectometry using cyclic simplex codes

    E-Print Network [OSTI]

    Park, Namkyoo

    Cyclic simplex coded OTDR SNR enhancement of coded optical time domain reflectometry using cyclic simplex codes *, , , e-mail : nkpark@plaza.snu.ac.kr Abstract: We propose and experimentally demonstrate the performance improvement of a coded optical time domain reflectometry using cyclic simplex

  16. Extended quantum color coding

    SciTech Connect (OSTI)

    Hayashi, A.; Hashimoto, T.; Horibe, M. [Department of Applied Physics, Fukui University, Fukui 910-8507 (Japan)

    2005-01-01T23:59:59.000Z

    The quantum color coding scheme proposed by Korff and Kempe [e-print quant-ph/0405086] is easily extended so that the color coding quantum system is allowed to be entangled with an extra auxiliary quantum system. It is shown that in the extended scheme we need only {approx}2{radical}(N) quantum colors to order N objects in large N limit, whereas {approx}N/e quantum colors are required in the original nonextended version. The maximum success probability has asymptotics expressed by the Tracy-Widom distribution of the largest eigenvalue of a random Gaussian unitary ensemble (GUE) matrix.

  17. CONCEPT computer code

    SciTech Connect (OSTI)

    Delene, J.

    1984-01-01T23:59:59.000Z

    CONCEPT is a computer code that will provide conceptual capital investment cost estimates for nuclear and coal-fired power plants. The code can develop an estimate for construction at any point in time. Any unit size within the range of about 400 to 1300 MW electric may be selected. Any of 23 reference site locations across the United States and Canada may be selected. PWR, BWR, and coal-fired plants burning high-sulfur and low-sulfur coal can be estimated. Multiple-unit plants can be estimated. Costs due to escalation/inflation and interest during construction are calculated.

  18. A study of monogenetic trematodes from marine fishes of Port Aransas, Texas, with a general review of the group

    E-Print Network [OSTI]

    Koratha, Kannenkeri John

    1953-01-01T23:59:59.000Z

    and thanks are extended to Dr. Gordon Gunter of supplying transoortation facilities to visit the f1sh markets To others, like the several sports and commercial the Institute of Mar1ne Sc1ence, Port Arsnsas, for the use of the laboratory facilities... in Port Aransas and is ideally situated for Marine Biological work. The summer months attract several hundreds of sports fishermen to Port Aransas from all over the country. There are also several fish markets with land ing places for fishing boats...

  19. Coding for Transmission Coding for Compression Bonus Section CMPSCI 240: Reasoning about Uncertainty

    E-Print Network [OSTI]

    McGregor, Andrew

    Coding for Transmission Coding for Compression Bonus Section CMPSCI 240: Reasoning about: April 29, 2014 #12;Coding for Transmission Coding for Compression Bonus Section Information Theory. #12;Coding for Transmission Coding for Compression Bonus Section Encoding Messages with Redundancy

  20. Course Code: Course Title

    E-Print Network [OSTI]

    Painter, Kevin

    - Frameworks; Decision Making Development life-cycle of a software system Bi-directional influence between-Critical Systems; Technology & Society. Brave New Worlds - Co-operative Computing; eLife. Learning OutcomesCourse Code: F29PD Course Title: Professional Development Course Co-ordinator: Sandy Jean

  1. The Woodland Carbon Code

    E-Print Network [OSTI]

    The Woodland Carbon Code While society must continue to make every effort to reduce greenhouse gas a role by removing carbon dioxide from the atmosphere. The potential of woodlands to soak up carbon to help compensate for their carbon emissions. But before investing in such projects, people want to know

  2. Chaotic Turbo Codes

    E-Print Network [OSTI]

    S. Adrian Barbulescu; Andrew Guidi; Steven S. Pietrobon

    This paper describes a new class of codes, chaotic turbo codes. They were born from a symbiosis between a chaotical digital encoder and a turbo code. This paper investigates the most important properties of both chaotic digital encoders and turbo encoders in order to understand how the two complement each other. A Chaotic Turbo Encoder is then described and initial results will be presented. I. INTRODUCTION A chaotic digital encoder was defined for the first time in [1] as a non--linear digital filter with finite precision (8 bits) which behaves in a quasi--chaotic fashion, both with zero and nonzero input sequences. A simple chaotic encoder is shown in Figure 1 [1]. D Y k X k LCIRC D Figure 1: Chaotic Digital Encoder Mapper L L L L L L 1 The main features of chaotic digital encoders that are used in this paper are: # The system is digital which makes possible its integration with a turbo code. # The output of a chaotic digital encoder with arbitrary inputs has a broad...

  3. Second Line of Defense Megaports Initiative Sustainment Plan - Port Klang Malaysia

    SciTech Connect (OSTI)

    King, Curtis A.

    2009-09-29T23:59:59.000Z

    To reduce the risk of illicit trafficking of special nuclear and other radiological materials, the Megaports Initiative installs radiation detection systems at international seaports. Port Klang, Malaysia, is one such seaport identified by the Megaports Initiative as a key area to install equipment to accomplish the mission of preventing the acquisition and smuggling of materials that could be used to create weapons of mass destruction or radiological dispersal devices. Sustainability is a critical factor of all components of the Megaports Initiative. The sustainability plan is developed to assist the partner country in securing the technical, financial, and policy commitments required to develop and implement a country-specific strategy. A robust sustainability plan will define the long-term relationship between the U.S. Department of Energy and the Government of Malaysia as well as promote the ongoing proficient radiation detection system operations at Port Klang, Malaysia.

  4. Solid waste workers and livelihood strategies in Greater Port-au-Prince, Haiti

    SciTech Connect (OSTI)

    Noel, Claudel, E-mail: claudelnoel@gmail.co [University of the West Indies, Institute for Sustainable Development, Environmental Management Unit, 13 Gibraltar Camp Way, Mona Campus, Kingston (Jamaica)

    2010-06-15T23:59:59.000Z

    The solid waste management industry in Haiti is comprised of a formal and an informal sector. Many basic activities in the solid waste management sector are being carried out within the context of profound poverty, which exposes the failure of the socioeconomic and political system to provide sufficient job opportunities for the urban population. This paper examines the involvement of workers in the solid waste management industry in Greater Port-au-Prince and the implications for livelihood strategies. The findings revealed that the Greater Port-au-Prince solid waste management system is very inclusive with respect to age, while highly segregated with regard to gender. In terms of earning capacity, the results showed that workers hired by the State agencies were the most economically vulnerable group as more than 50% of them fell below the official nominal minimum wage. This paper calls for better salary scales and work compensation for the solid waste workers.

  5. Soil Erosion and Sediment Control Act, Soil and Water Conservation District, and Council on Soil and Water Conservation Regulations (Connecticut)

    Broader source: Energy.gov [DOE]

    These regulations establish Soil and Water Conservation Districts throughout the State of Connecticut. Each district has its own Board of Directors; membership and election procedures are defined...

  6. Well blowout rates in California Oil and Gas District 4--Update and Trends

    E-Print Network [OSTI]

    Benson, Sally M.

    2010-01-01T23:59:59.000Z

    geologic assessment of oil and gas in the San Joaquin BasinRates in California Oil and Gas District 4 – Update andoccurring in California Oil and Gas District 4 during the

  7. E-Print Network 3.0 - angetu district southeastern Sample Search...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Florida USA Summary: -3201 Doubling the Energy Advantage of Waste-to-Energy: District Heating in the Northeast U.S. Priscilla Ulloa... In District Heating (DH), a large number...

  8. RELATING TO LOCAL GOVERNMENT; ENACTING THE RENEWABLE ENERGY FINANCING DISTRICT ACT; AUTHORIZING MUNICIPALITIES AND

    E-Print Network [OSTI]

    Kammen, Daniel M.

    TO LOCAL GOVERNMENT; ENACTING THE RENEWABLE ENERGY FINANCING DISTRICT ACT; AUTHORIZING MUNICIPALITIES to encourage the development of distributed generation renewable energy sources and the installation. the creation and administration of renewable energy financing districts to facilitate the development

  9. District Superintendent and School Board President Perceptions Regarding Leadership Characteristics for Superintendents of Texas Schools

    E-Print Network [OSTI]

    Groholski, Kenneth L.

    2010-07-14T23:59:59.000Z

    presidents of Texas public schools. The population was superintendents and school board presidents from Texas Public Schools. The population was divided into large school districts (>10,000 students) and small school districts (students). Data...

  10. The Energy Resource Center: On-Site Technical Assistance and Training Programs for Texas School Districts

    E-Print Network [OSTI]

    Roberts, M.; Sanders, M.

    1988-01-01T23:59:59.000Z

    Created by the 68th Session of the Texas Legislature, the Energy Resource Center for Texas Schools (ERC) is the primary source of facility management services for Texas School districts. The purpose of the ERC is to assist school districts...

  11. Geographic information system (GIS) and simulation model for management of irrigation districts

    E-Print Network [OSTI]

    Nazarov, Azimjon S.

    2000-01-01T23:59:59.000Z

    IDMM (Irrigation District Management Model), a user friendly, GIS based, menu driven personal computer software program, was developed as a planning and management tool for improved water use and crop growth production in irrigation districts...

  12. City of Allentown assessment of a district heating system

    SciTech Connect (OSTI)

    Oliker, I.; Tamayne, T.

    1982-09-01T23:59:59.000Z

    The energy sources selected to accommodate the heat load consist of five 10 MWt units at the high temperature hot water generating station, ten 10 MWt units at the high temperature hot water generating station, and two 25 MWe (37.5 MWt) cogenerating fluidized bed combustion units at the incinerator site. The service area selected consists of the downtown commercial district. Total peak heat load for the forty seven block commercial district and twenty two industrial customers is estimated to be 187 MWt. The following aspects are covered: transmission and distribution piping systems, development strategy, capital costs and construction schedule, operation, economics, environmental analysis, and community impact.

  13. Port of Houston Intermodal Grain Transfer System and Market Area, 1976 - 1977.

    E-Print Network [OSTI]

    Fuller, Stephen W.; Paggi, Mechel S.

    1978-01-01T23:59:59.000Z

    to 41 feet. This implies that these vessels grain at the Port of Houston. Practical experience has were not able to be fully loaded. Bulk carriers and tank- shown that up to a point, the larger the ship employed in the transport of bulk cargoes... AND SHIPMENT PATTERNS ............... 12 MODES OF TRANSPORTATION ON GRAIN AND SOYBEAN RECEIPTS ..................................... 14 FOREIGN DESTl NATIONS ..................................... 14 CARGO SIZES BY DESTINATION AND COMMODITY .......... 14...

  14. Erasure Techniques in MRD codes

    E-Print Network [OSTI]

    W. B. Vasantha Kandasamy; Florentin Smarandache; R. Sujatha; R. S. Raja Durai

    2012-05-03T23:59:59.000Z

    This book is organized into six chapters. The first chapter introduces the basic algebraic structures essential to make this book a self contained one. Algebraic linear codes and their basic properties are discussed in chapter two. In chapter three the authors study the basic properties of erasure decoding in maximum rank distance codes. Some decoding techniques about MRD codes are described and discussed in chapter four of this book. Rank distance codes with complementary duals and MRD codes with complementary duals are introduced and their applications are discussed. Chapter five introduces the notion of integer rank distance codes. The final chapter introduces some concatenation techniques.

  15. Community Renewable Energy Success Stories Webinar: District Heating with Renewable Energy (text version)

    Office of Energy Efficiency and Renewable Energy (EERE)

    Below is the text version of the webinar titled "District Heating with Renewable Energy," originally presented on November 20, 2012.

  16. Well blowout rates in California Oil and Gas District 4--Update and Trends

    E-Print Network [OSTI]

    Benson, Sally M.

    2010-01-01T23:59:59.000Z

    Oil and Gas District 4 from 1991 to 2005: implications for geological storage of carbon dioxide, Environmental Geology ,

  17. 1993-1994 Final technical report for establishing the SECME Model in the District of Columbia

    SciTech Connect (OSTI)

    Vickers, R.G.

    1995-12-31T23:59:59.000Z

    This is the final report for a program to establish the SECME Model in the District of Columbia. This program has seen the development of a partnership between the District of Columbia Public Schools, the University of the District of Columbia, the Department of Energy, and SECME. This partnership has demonstrated positive achievement in mathematics and science education and learning in students within the District of Columbia.

  18. Well blowout rates in California Oil and Gas District 4--Update and Trends

    E-Print Network [OSTI]

    Benson, Sally M.

    2010-01-01T23:59:59.000Z

    developed for CO2- enhanced oil recovery, SPE Paper 112924 ,oil production in the District was via thermally enhanced recovery.

  19. Partnering for environmental restoration: The Port Hope Harbour Remedial Action Plan (RAP)

    SciTech Connect (OSTI)

    Weston, S.M.C. [Environment Canada, Toronto, Ontario (Canada)

    1995-12-31T23:59:59.000Z

    A Remedial Action Plan (RAP) is being developed for Port Hope Harbour, one of 43 Areas of Concern (AOCs) identified by the International Joint Commission (IJC). The RAP, when implemented, will lead to the restoration and protection of desirable water conditions in Port Hope Harbour. The environmental concern associated with the harbor can be best viewed as a historical contaminated sediment problem. Approximately 90,000 m{sup 3} of sediment located in Port Hope Harbour`s turning basin and west slip are contaminated by uranium and thorium series radionuclides, heavy metals, and PCBs. There are several groups contributing to the development of the RAP. All of these groups have the common goal of developing an environmentally sound plan that reflects the views of the community. Strategic partnerships have been established that recognize the need to integrate and coordinate the efforts of all agencies, stakeholders, and the community. The objective is to develop an environmentally sound remediation plan through an efficient and effective management framework.

  20. Money for deeper US coal ports: needed or just more pork barrel

    SciTech Connect (OSTI)

    Madison, C.

    1981-02-07T23:59:59.000Z

    The US must improve its port facilities before the coal industry can become a major world exporter. The coal and rail industries plan to improve coal-handling facilities at ports on the East, Gulf, and West Coasts, but dredging to allow coal carriers must be done by the Corps of Engineers under Congressional authorization. This process could take up to 20 years to resolve bureaucratic and cost barriers. Although coal exports could improve the balance-of-payments deficit, the Federal government does not want to subsidize port facilities on the basis of future market projections. A task force study estimates a European market of 189 million tons of steam coal in 1990 and 90 million tons for the Far East. The study recommends dredging to keep US coal competitive and to meet the energy needs of US allies. An effort to speed up authorizing legislation allows the Corps to prepare a single environmental impact statement and feasibility study for several projects rather than follow the multi-step procedure for each. The new Senate leadership may prefer omnibus legislation that alters water policy and protects the budget. (DCK)

  1. REDUCED-COMPLEXITY DECODING FOR CONCATENATED CODES BASED ON RECTANGULAR PARITY-CHECK CODES AND TURBO CODES

    E-Print Network [OSTI]

    Wong, Tan F.

    AND TURBO CODES John M. Shea and Tan F. Wong University of Florida Department of Electrical and Computer-check code (RPCC) with a turbo code. These concatenated codes are referred to as RPCC+turbo codes. RPCC+turbo codes have been shown to significantly outperform turbo codes in several scenarios [1],[2]. One

  2. Reducing cold start hydrocarbon emissions from port fuel injected spark ignition engines with improved management of hardware & controls

    E-Print Network [OSTI]

    Lang, Kevin R., 1980-

    2006-01-01T23:59:59.000Z

    An experimental study was performed to investigate strategies for reducing cold start hydrocarbon (HC) emissions from port fuel injected (PFI) spark ignition (SI) engines with better use of existing hardware and control ...

  3. Imagen Ponce : public and private interests in the design of a free zone within the Port of Ponce, Puerto Rico

    E-Print Network [OSTI]

    Ferre, Hermann

    1989-01-01T23:59:59.000Z

    This thesis explores the physical and spatial requirements that would allow a free trade zone to operate efficiently within the Port of Ponce. The form of this economic enterprise is seen as an integration of the industrial ...

  4. Proceedings of the US Hydrographic Conference, Tampa, FL, 25-28 Apr 2011 THE PORT OF NORFOLK PROJECT

    E-Print Network [OSTI]

    New Hampshire, University of

    Proceedings of the US Hydrographic Conference, Tampa, FL, 25-28 Apr 2011 1 THE PORT OF NORFOLK;Proceedings of the US Hydrographic Conference, Tampa, FL, 25-28 Apr 2011 2 Background Creating raster

  5. A Functional Regression Approach for Prediction in a District-Heating System

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    A Functional Regression Approach for Prediction in a District-Heating System Aldo Goia Dipartimento in a district heating sys- tem. Our dataset consists of four separated periods, with 198 days each period and 24 load forecasting, district heat- ing system Introduction Among the activities of support

  6. Solar heat storages in district heating Klaus Ellehauge Thomas Engberg Pedersen

    E-Print Network [OSTI]

    References 45 Appendix 1 Danish companies 48 #12;6/50 Solar heat storages in district heating networksJuly 2007 . #12;#12;Solar heat storages in district heating networks July 2007 Klaus Ellehauge 97 22 11 tep@cowi.dk www.cowi.com #12;#12;Solar heat storages in district heating networks 5

  7. Technical Report -DTU -Informatics and Mathematical Modeling (May 31, 2007) Temperature Prediction in District

    E-Print Network [OSTI]

    Prediction in District Heating Systems with cFIR models Pierre Pinson , Torben S. Nielsen, Henrik Aa. Nielsen, Lyngby, Denmark Abstract Current methodologies for the optimal operation of district heating systems regularization. Results are given for the test case of the Roskilde district heating system, over a period

  8. Skyscrapers and District Heating, an inter-related History 1876-1933.

    E-Print Network [OSTI]

    Boyer, Edmond

    Skyscrapers and District Heating, an inter-related History 1876-1933. Introduction: The aim, and an equally new urban infrastructure, district heating, both of witch were born in the north-east United example in Europe of skyscrapers and district heating planned together, at Villeurbanne near Lyons

  9. School of Architecture, Design and the Built Environment Delta T optimisation of district heating network

    E-Print Network [OSTI]

    Evans, Paul

    School of Architecture, Design and the Built Environment Delta T optimisation of district heating of any network. Most existing district heating systems work at small (10-15 C) delta T. Although for the conventional and optimised design of the district heating network. The network operation will be simulated

  10. Coded modulation with Low Density Parity Check codes

    E-Print Network [OSTI]

    Narayanaswami, Ravi

    2001-01-01T23:59:59.000Z

    This thesis proposes the design of Low Density Parity Check (LDPC) codes for cases where coded modulation is used. We design these codes by extending the idea of Density Evolution (DE) that has been introduced as a powerful tool to analyze LDPC...

  11. Generating Code for High-Level Operations through Code Composition

    E-Print Network [OSTI]

    Generating Code for High-Level Operations through Code Composition James M. Stichnoth August 1997 of the authors and should not be interpreted as necessarily representing the official policies or endorsements: Compilers, code generation, parallelism, communication generation #12;Abstract A traditional compiler

  12. Multiclass learning with simplex coding

    E-Print Network [OSTI]

    Mroueh, Youssef

    In this paper we discuss a novel framework for multiclass learning, defined by a suitable coding/decoding strategy, namely the simplex coding, that allows us to generalize to multiple classes a relaxation approach commonly ...

  13. Distributed control of coded networks

    E-Print Network [OSTI]

    Zhao, Fang, Ph. D. Massachusetts Institute of Technology

    2010-01-01T23:59:59.000Z

    The introduction of network coding has the potential to revolutionize the way people operate networks. For the benefits of network coding to be realized, distributed solutions are needed for various network problems. In ...

  14. Nevada Energy Code for Buildings

    Broader source: Energy.gov [DOE]

    ''Much of the information presented in this summary is drawn from the U.S. Department of Energy’s (DOE) Building Energy Codes Program and the Building Codes Assistance Project (BCAP). For more...

  15. Confocal coded aperture imaging

    DOE Patents [OSTI]

    Tobin, Jr., Kenneth William (Harriman, TN); Thomas, Jr., Clarence E. (Knoxville, TN)

    2001-01-01T23:59:59.000Z

    A method for imaging a target volume comprises the steps of: radiating a small bandwidth of energy toward the target volume; focusing the small bandwidth of energy into a beam; moving the target volume through a plurality of positions within the focused beam; collecting a beam of energy scattered from the target volume with a non-diffractive confocal coded aperture; generating a shadow image of said aperture from every point source of radiation in the target volume; and, reconstructing the shadow image into a 3-dimensional image of the every point source by mathematically correlating the shadow image with a digital or analog version of the coded aperture. The method can comprise the step of collecting the beam of energy scattered from the target volume with a Fresnel zone plate.

  16. Remediation of Centre Pier, Port Hope, Ontario: Historical, Logistical, Regulatory and Technical Challenges - 13118

    SciTech Connect (OSTI)

    Ferguson Jones, Andrea [MMM Group Limited, 100 Commerce Valley Drive West, Thornhill, Ontario, L3T 0A1 (Canada)] [MMM Group Limited, 100 Commerce Valley Drive West, Thornhill, Ontario, L3T 0A1 (Canada); Case, Glenn [Atomic Energy of Canada Limited, 115 Toronto Road, Port Hope, Ontario, L1A 3S4 (Canada)] [Atomic Energy of Canada Limited, 115 Toronto Road, Port Hope, Ontario, L1A 3S4 (Canada); Lawrence, Dave [Public Works and Government Services Canada, 115 Toronto Road, Port Hope, Ontario, L1A 3S4 (Canada)] [Public Works and Government Services Canada, 115 Toronto Road, Port Hope, Ontario, L1A 3S4 (Canada)

    2013-07-01T23:59:59.000Z

    Centre Pier is a 3.9 ha property owned by the Commissioners of the Port Hope Harbour in the Municipality of Port Hope, Ontario, Canada. It is centrally located on the Port Hope waterfront and is bounded on the west by the Port Hope Harbour, on the east by the Ganaraska River, on the south by Lake Ontario, and on the north by a railway corridor. The property is currently leased by the Commissioners of the Port Hope Harbour to the Cameco Corporation which owns the four onsite building that are used as warehouse space for their uranium conversion facility located on the western side of the Harbour. Remediation of this site forms part of the Port Hope Project being undertaken by Atomic Energy of Canada Limited (AECL) and Public Works and Government Services Canada (PWGSC) as part of the Port Hope Area Initiative (PHAI). Soil impacts include radiological, metals and petroleum hydrocarbons resulting from long term historical industrial use. Radiological impacts in soil extend across most of the site primarily within the upper metre of fill. Metals-contaminated soil is present across the entire site in the underlying fill material. The metals-contaminated fill extends to a maximum depth of 2.0 m below grade at the north end of the site which is underlain by peat. However, the metals-contaminated soil could extend to the top of the bedrock on the remainder of the site. Based on the elevation of the bedrock in the adjacent river and Harbour Basin, the metals-contaminated soil may extend to a depth of 5.6 m or 6.5 m below existing grade. Petroleum-contaminated soil is present on the southeast side of the site, where a storage tank farm was previously located. Challenges include: - The complex history of the site both relating to site use and Pier construction. Pier development began in the 1800's and was undertaken by many different entities. Modifications and repairs were made over the years resulting in several different types of Pier walls and fill that must be considered during remediation. A wide variety of industrial activity on the Pier including extensive foundry operations as well as the industrial nature of the fill used to construct the Pier has resulted in extensive contamination distribution. The Pier structure will require reinforcement to permit both the remediation of the Pier and the adjacent Harbour and remediation techniques will need to be well suited to minimize disruption of wall structures as well as being able to deal with fill ranging from ash to boulders. - Multiple stakeholders are responsible for building demolition, remediation of radiological impacts, remediation of industrial impacts and the use of the site as a staging area for Harbour sediment remediation. The successful remediation of the Centre Pier will require careful negotiation and planning for the various remediation activities noted above. - The depth of contamination on the Pier would result in the complete removal of the Pier if all contamination were to be excavated. Therefore, a Risk Assessment will be conducted to determine the appropriate means for in situ risk management for materials to be left in place below a proposed depth of 1.5 m below current grade. With the concurrence of the property owners and Provincial regulators, the Risk Assessment will be undertaken in accordance with the Provincial requirements that will ensure adequate protection of the environment and future users of the site. - The end use of the Pier has yet to be confirmed by the Municipality. (authors)

  17. A CONTINUOUS TRANSFORMATION USEFUL FOR DISTRICTING W. R. Tobler

    E-Print Network [OSTI]

    Tobler, Waldo

    so that areas with many people would appear large, and areas with few people would appear small could stretch a geographical map so that areas containing many people would appear large, and areas equal numbers of people. Drawing on such maps should simplify the process of creating district

  18. ENVIRONMENTAL ASSESSMENT/REGULATORY IMPACT REVIEW PROPOSAL TO CREATE DISTRICTS

    E-Print Network [OSTI]

    FINAL ENVIRONMENTAL ASSESSMENT/REGULATORY IMPACT REVIEW FOR THE PROPOSAL TO CREATE DISTRICTS WITHIN. . . . . . . . . . . . . . . . . 2 1.2.1Environmental Assessment. . . . . . . . . . . . . . 2 1.2.2Regulatory Impact Review . . . . . . . . . . . . . . . . . . . . . . . . . 3 2.0 ENVIRONMENTAL AND BIOLOGICAL IMPACTS . . . . . . . . . . . . . 4 2.1 Atka Mackerel Biology

  19. CALIFORNIA ENERGY COMMISSION SPECIAL DISTRICTS HOSPITALS & PUBLIC CARE COLLEGES & UNIVERSITIES

    E-Print Network [OSTI]

    Whether you are building a new facility, renovating an existing one, or want to reduce your energy billsCALIFORNIA ENERGY COMMISSION SPECIAL DISTRICTS HOSPITALS & PUBLIC CARE COLLEGES & UNIVERSITIES F O 2004 www.energy.ca.gov/efficiency/partnership Call (916) 654-4147 #12;The Energy Partnership Program

  20. Changing times, changing places: AIDS orphans in Kisumu District, Kenya

    E-Print Network [OSTI]

    Richner, Heinz

    Changing times, changing places: AIDS orphans in Kisumu District, Kenya Prevalence of AIDS orphans in Kenya (2.6 million) had been orphaned by AIDS. In 1999, 46,732 children (17 years old care. Although Kenya has clear policies on prevention and management of HIV, it lacks a policy

  1. RESOLUTION NO. 2011-82 ADOPTING MODESTO IRRIGATION DISTRICT'S RENEWABLE

    E-Print Network [OSTI]

    RESOLUTION NO. 2011-82 ADOPTING MODESTO IRRIGATION DISTRICT'S RENEWABLE ENERGY RESOURCES Standard (RPS) in an effort to meet 20 percent ofits retail energy sales with renewable resources by 2017 for consideration by the Board of Directors, attached hereto as Attachment A, Renewable Energy Resources Enforcement

  2. Energy Efficient Design Concept for Mesquite Independent School District

    E-Print Network [OSTI]

    Maxwell, C. L.

    1988-01-01T23:59:59.000Z

    Mesquite is a suburb located on the east side of Dallas with a population of approximately 110,000. The school district covers over 60 square miles with a student population of 22,500. The 32 schools consist of 23 elementary, 5 middle and 4 high...

  3. DC WRRC Report. No. 36 DISTRICT OF COLUMBIA

    E-Print Network [OSTI]

    District of Columbia, University of the

    Quality II-7 Patuxent River Basin II-10 Potomac Estuary II-12 CHAPTER III - LEGAL AND INSTITUTIONAL the District is prepared to deal with these issues. The study begins with a description of the Potomac River Problems I-12 CHAPTER II - THE POTOMAC RIVER BASIN Tributaries II-1 Precipitation and Runoff II-3 Water

  4. Comparing the Effects of Mutualism and Competition on Industrial Districts

    E-Print Network [OSTI]

    Hoyle, Rebecca B.

    stations. The diversity of industries situated in the region include food processing industries, oil refining, chemical and bio-chemical produc- tion facilities, as well as heavy industrial facilitiesComparing the Effects of Mutualism and Competition on Industrial Districts Christopher J.K. Knighta

  5. MELCOR computer code manuals

    SciTech Connect (OSTI)

    Summers, R.M.; Cole, R.K. Jr.; Smith, R.C.; Stuart, D.S.; Thompson, S.L. [Sandia National Labs., Albuquerque, NM (United States); Hodge, S.A.; Hyman, C.R.; Sanders, R.L. [Oak Ridge National Lab., TN (United States)

    1995-03-01T23:59:59.000Z

    MELCOR is a fully integrated, engineering-level computer code that models the progression of severe accidents in light water reactor nuclear power plants. MELCOR is being developed at Sandia National Laboratories for the U.S. Nuclear Regulatory Commission as a second-generation plant risk assessment tool and the successor to the Source Term Code Package. A broad spectrum of severe accident phenomena in both boiling and pressurized water reactors is treated in MELCOR in a unified framework. These include: thermal-hydraulic response in the reactor coolant system, reactor cavity, containment, and confinement buildings; core heatup, degradation, and relocation; core-concrete attack; hydrogen production, transport, and combustion; fission product release and transport; and the impact of engineered safety features on thermal-hydraulic and radionuclide behavior. Current uses of MELCOR include estimation of severe accident source terms and their sensitivities and uncertainties in a variety of applications. This publication of the MELCOR computer code manuals corresponds to MELCOR 1.8.3, released to users in August, 1994. Volume 1 contains a primer that describes MELCOR`s phenomenological scope, organization (by package), and documentation. The remainder of Volume 1 contains the MELCOR Users Guides, which provide the input instructions and guidelines for each package. Volume 2 contains the MELCOR Reference Manuals, which describe the phenomenological models that have been implemented in each package.

  6. Travel Codes Traveler Is Employee

    E-Print Network [OSTI]

    Arnold, Jonathan

    Travel Codes Traveler Is Employee: 64100-Domestic Travel 64150-Mileage 64200-International Travel Supplies & Expense Codes 71410-Office Supplies 71430-Lab/Research Supplies (dollar value of each item less Charges Equipment Codes 84320-Equipment (non-computer & peripherals) with a cost of $5,000.00 or more per

  7. Rotationally invariant multilevel block codes

    E-Print Network [OSTI]

    Kulandaivelu, Anita

    1993-01-01T23:59:59.000Z

    The objective of this thesis is to evaluate the performance of block codes that are designed to be rotationally invariant, in a multilevel coding scheme, over a channel modelled to be white gaussian noise. Also, the use of non-binary codes...

  8. Design of proximity detecting codes

    E-Print Network [OSTI]

    Perisetty, Srinivas

    1997-01-01T23:59:59.000Z

    delay insensitive, codes like unordered codes have been proposed. Although these codes are delay insensitive, the receiver still has to wait for all the 1s in the transmitted data to be received before sending an acknowledge signal to the sender. A new...

  9. Code for Hydrogen Hydrogen Pipeline

    E-Print Network [OSTI]

    #12;2 Code for Hydrogen Pipelines Hydrogen Pipeline Working Group Workshop Augusta, Georgia August development · Charge from BPTCS to B31 Standards Committee for Hydrogen Piping/Pipeline code development · B31.12 Status & Structure · Hydrogen Pipeline issues · Research Needs · Where Do We Go From Here? #12;4 Code

  10. Energy Codes and Standards: Facilities

    SciTech Connect (OSTI)

    Bartlett, Rosemarie; Halverson, Mark A.; Shankle, Diana L.

    2007-01-01T23:59:59.000Z

    Energy codes and standards play a vital role in the marketplace by setting minimum requirements for energy-efficient design and construction. They outline uniform requirements for new buildings as well as additions and renovations. This article covers basic knowledge of codes and standards; development processes of each; adoption, implementation, and enforcement of energy codes and standards; and voluntary energy efficiency programs.

  11. PERFORMANCE EVALUATION OF TURBO CODES

    E-Print Network [OSTI]

    Alajaji, Fady

    PERFORMANCE EVALUATION OF TURBO CODES by Guangchong Zhu A project submitted to the Department named ``Turbo codes'' which claims an extraordinary performance with reasonable decoding complexity. In this project, we begin with a study on the structure and principle of Turbo codes. We then investigate

  12. Southeast Energy Efficiency Alliance's Building Energy Codes...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Southeast Energy Efficiency Alliance's Building Energy Codes Project Southeast Energy Efficiency Alliance's Building Energy Codes Project Building Codes Project for the 2013...

  13. 2013 Reporting Unit Codes | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    2013 Reporting Unit Codes 2013 Reporting Unit Codes CFC Reporting Unit Codes 2013.pdf More Documents & Publications EA-0372: Final Environmental Assessment Alignment: Achieving...

  14. Error Floors of LDPC Codes and Related Topics

    E-Print Network [OSTI]

    Butler, Brian K.

    Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2.2 LDPC Codes . . . . . . . .2.1 Binary Linear Block Codes . . . . . . .

  15. Report to Congress on Server and Data Center Energy Efficiency: Public Law 109-431: Appendices

    E-Print Network [OSTI]

    Brown, Richard; Alliance to Save Energy; ICF Incorporated; ERG Incorporated; U.S. Environmental Protection Agency

    2008-01-01T23:59:59.000Z

    and universities, cities and towns, counties, school districts, ports, libraries, hospitals, and health districts which provides free energy audits.

  16. Port City

    E-Print Network [OSTI]

    Garcia, Angel Noe

    2012-01-01T23:59:59.000Z

    a ticket slipped beneath the wiper blade, already wrinkledon the cold of early morning, wiper blades cut through mist.

  17. T ID CODE I

    National Nuclear Security Administration (NNSA)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA Approved:AdministrationAnalysisDarby Dietrich5 | NUMBER 1 | MARCHT ID CODE I

  18. Coding for Transmission Coding for Compression Bonus Section CMPSCI 240: Reasoning about Uncertainty

    E-Print Network [OSTI]

    McGregor, Andrew

    Coding for Transmission Coding for Compression Bonus Section CMPSCI 240: Reasoning about 1, 2013 #12;Coding for Transmission Coding for Compression Bonus Section Information Theory Encoding for Transmission Coding for Compression Bonus Section Encoding Messages with Redundancy: Error Correcting Suppose

  19. Experiences in the Performance Analysis and Optimization of a Deterministic Radiation Transport Code on the Cray SV1

    SciTech Connect (OSTI)

    Peter Cebull

    2004-05-01T23:59:59.000Z

    The Attila radiation transport code, which solves the Boltzmann neutron transport equation on three-dimensional unstructured tetrahedral meshes, was ported to a Cray SV1. Cray's performance analysis tools pointed to two subroutines that together accounted for 80%-90% of the total CPU time. Source code modifications were performed to enable vectorization of the most significant loops, to correct unfavorable strides through memory, and to replace a conjugate gradient solver subroutine with a call to the Cray Scientific Library. These optimizations resulted in a speedup of 7.79 for the INEEL's largest ATR model. Parallel scalability of the OpenMP version of the code is also discussed, and timing results are given for other non-vector platforms.

  20. Underwater survey and excavation at the ancient port of Gravisca, Italy

    E-Print Network [OSTI]

    Shuey, Elizabeth Bostwick

    1978-01-01T23:59:59.000Z

    and endless energy cnd enthusiasm throughout the long weeks of diving or waiting out siroc- co storms. I am also grateful to the Ameri. can Institute of Nautical Archaeology for its support. My sincere appreciation goes also to the many individuals who con... development, the Tuscan coast of Italy (FIC. 1) presents as much of a challenge today to archaeologists interpreting port remains as it did to the earliest seafarers who sought shelter for their ships. In contrast to the bay-studded Aegean so con- 1 duclve...

  1. U-126: Cisco Adaptive Security Appliances Port Forwarder ActiveX Control Buffer Overflow Vulnerability

    Broader source: Energy.gov [DOE]

    A vulnerability was reported in Cisco ASA. A remote user can cause arbitrary code to be executed on the target user's system.

  2. Quantum serial turbo-codes

    E-Print Network [OSTI]

    David Poulin; Jean-Pierre Tillich; Harold Ollivier

    2009-06-10T23:59:59.000Z

    We present a theory of quantum serial turbo-codes, describe their iterative decoding algorithm, and study their performances numerically on a depolarization channel. Our construction offers several advantages over quantum LDPC codes. First, the Tanner graph used for decoding is free of 4-cycles that deteriorate the performances of iterative decoding. Secondly, the iterative decoder makes explicit use of the code's degeneracy. Finally, there is complete freedom in the code design in terms of length, rate, memory size, and interleaver choice. We define a quantum analogue of a state diagram that provides an efficient way to verify the properties of a quantum convolutional code, and in particular its recursiveness and the presence of catastrophic error propagation. We prove that all recursive quantum convolutional encoder have catastrophic error propagation. In our constructions, the convolutional codes have thus been chosen to be non-catastrophic and non-recursive. While the resulting families of turbo-codes have bounded minimum distance, from a pragmatic point of view the effective minimum distances of the codes that we have simulated are large enough not to degrade the iterative decoding performance up to reasonable word error rates and block sizes. With well chosen constituent convolutional codes, we observe an important reduction of the word error rate as the code length increases.

  3. Conjugate Codes and Applications to Cryptography

    E-Print Network [OSTI]

    Mitsuru Hamada

    2006-10-23T23:59:59.000Z

    A conjugate code pair is defined as a pair of linear codes such that one contains the dual of the other. The conjugate code pair represents the essential structure of the corresponding Calderbank-Shor-Steane (CSS) quantum code. It is argued that conjugate code pairs are applicable to quantum cryptography in order to motivate studies on conjugate code pairs.

  4. Turbo and LDPC Codes: Implementation, Simulation,

    E-Print Network [OSTI]

    Valenti, Matthew C.

    1 Turbo and LDPC Codes: Implementation, Simulation, and Standardization June 7, 2006 Matthew/7/2006 Turbo and LDPC Codes 2/133 Tutorial Overview Channel capacity Convolutional codes ­ the MAP algorithm Turbo codes ­ Standard binary turbo codes: UMTS and cdma2000 ­ Duobinary CRSC turbo codes: DVB

  5. Espace mtis, espace dtruit, espace exemplaire : District Six, Cape Town

    E-Print Network [OSTI]

    Boyer, Edmond

    a laissé une profonde empreinte à tous les niveaux (politique, social, culturel, foncier, 1Adresse actuelle population noire est soumise à un arsenal législatif déterminant lieu de résidence, droits fonciers, durée du enjeu de mémoire. Le cas de District Six permet d'éclairer la façon dont cette nouvelle nation s

  6. Changes in airborne lead particulate in Port Pirie, South Australia, 1986-1996

    SciTech Connect (OSTI)

    Esterman, A.J.; Maynard, E.J. [South Australian Health Commission, Adelaide, South Australia (Australia). Environmental Health Branch] [South Australian Health Commission, Adelaide, South Australia (Australia). Environmental Health Branch

    1998-11-01T23:59:59.000Z

    Port Pirie is 230 km north of Adelaide, the capital of South Australia. The major industry in the city is a lead smelter owned by Pasminco. Fume, dust, and fugitive emissions from the smelter have been deposited in and around Port Pirie over the past 100 years. The results presented in this paper are from an air monitoring station situated at the southeast entrance of the smelter, approximately 600 m from the blast furnace. Measurements include total suspended particulate (TSP) and total suspended particulate lead (TSPL) reported as concentrations ({micro}g/m{sup 3}). Data are available from 1986 to 1996 and consist of 548 measurements. Analysis of geometric mean concentration levels by wind direction showed that while for TSP there was little relationship with wind direction, TSPL increased substantially as the wind came from the direction of the smelter. An analysis of geometric mean concentration levels by wind speed showed that TSP was significantly correlated with wind speed for all wind sectors apart from winds coming from the smelter production area.

  7. Clark County- Energy Conservation Code

    Broader source: Energy.gov [DOE]

    In September 2010, Clark County adopted Ordinance 3897, implementing the Southern Nevada version of the 2009 International Energy Conservation Code for both residential and commercial buildings...

  8. Nonbinary Codeword Stabilized Quantum Codes

    E-Print Network [OSTI]

    Xie Chen; Bei Zeng; Isaac L. Chuang

    2008-08-22T23:59:59.000Z

    The codeword stabilized (CWS) quantum codes formalism presents a unifying approach to both additive and nonadditive quantum error-correcting codes (arXiv:0708.1021 [quant-ph]), but only for binary states. Here we generalize the CWS framework to the nonbinary case (of both prime and nonprime dimension) and map the search for nonbinary quantum codes to a corresponding search problem for classical nonbinary codes with specific error patterns. We show that while the additivity properties of nonbinary CWS codes are similar to the binary case, the structural properties of the nonbinary codes differ substantially from the binary case, even for prime dimensions. In particular, we identify specific structure patterns of stabilizer groups, based on which efficient constructions might be possible for codes that encode more dimensions than any stabilizer codes of the same length and distance; similar methods cannot be applied in the binary case. Understanding of these structural properties can help prune the search space and facilitate the identification of good nonbinary CWS codes.

  9. Marin County- Solar Access Code

    Broader source: Energy.gov [DOE]

    Marin County's Energy Conservation Code is designed to assure new subdivisions provide for future passive or natural heating or cooling opportunities in the subdivision to the extent feasible. ...

  10. Quantum Quasi-Cyclic LDPC Codes

    E-Print Network [OSTI]

    Manabu Hagiwara; Hideki Imai

    2010-08-28T23:59:59.000Z

    In this paper, a construction of a pair of "regular" quasi-cyclic LDPC codes as ingredient codes for a quantum error-correcting code is proposed. That is, we find quantum regular LDPC codes with various weight distributions. Furthermore our proposed codes have lots of variations for length, code rate. These codes are obtained by a descrete mathematical characterization for model matrices of quasi-cyclic LDPC codes. Our proposed codes achieve a bounded distance decoding (BDD) bound, or known as VG bound, and achieve a lower bound of the code length.

  11. Super Special Codes using Super Matrices

    E-Print Network [OSTI]

    W. B. Vasantha Kandasamy; Florentin Smarandache; K. Ilanthenral

    2010-06-30T23:59:59.000Z

    The new classes of super special codes are constructed in this book using the specially constructed super special vector spaces. These codes mainly use the super matrices. These codes can be realized as a special type of concatenated codes. This book has four chapters. In chapter one basic properties of codes and super matrices are given. A new type of super special vector space is constructed in chapter two of this book. Three new classes of super special codes namely, super special row code, super special column code and super special codes are introduced in chapter three. Applications of these codes are given in the final chapter.

  12. On the logical operators of quantum codes

    E-Print Network [OSTI]

    Mark M. Wilde

    2009-03-30T23:59:59.000Z

    I show how applying a symplectic Gram-Schmidt orthogonalization to the normalizer of a quantum code gives a different way of determining the code's logical operators. This approach may be more natural in the setting where we produce a quantum code from classical codes because the generator matrices of the classical codes form the normalizer of the resulting quantum code. This technique is particularly useful in determining the logical operators of an entanglement-assisted code produced from two classical binary codes or from one classical quaternary code. Finally, this approach gives additional formulas for computing the amount of entanglement that an entanglement-assisted code requires.

  13. Non-Residential Energy Code National and Regional Codes

    E-Print Network [OSTI]

    Non-Residential Energy Code Comparison National and Regional Codes David Baylon Mike Kennedy #12 2003 · ASHRAE 90.1 2001 & addenda · E-Benchmark Guidelines (NBI) #12;Approach · Comparison of the State;Approach (cont.) · Provisions compared ­ Lighting power ­ Lighting controls ­ Mechanical systems ­ Building

  14. Building and Facility Codes Code Building Location Bldg # Coordinates

    E-Print Network [OSTI]

    Russell, Lynn

    Building and Facility Codes Code Building Location Bldg # Coordinates APM Applied Physics & Mathematics Building Muir 249 F7 ASANT Asante Hall Eleanor Roosevelt 446 F5 BIO Biology Building Muir 259 F7 BIRCH Birch Aquarium SIO 2300 S-D7 BONN Bonner Hall Revelle 131 G8 BSB Biomedical Sciences Building

  15. Space time coded code division multiplexing on SC140 DSP

    E-Print Network [OSTI]

    Menon, Murali P

    2001-01-01T23:59:59.000Z

    The aim of this research is to design a high data rate wireless communication system for multi-path fading channels. Code-division multiplexing is proposed as a modulation scheme for a space-time coded multiple antenna system that would guarantee...

  16. Subclavian Vein Versus Arm Vein for Totally Implantable Central Venous Port for Patients with Head and Neck Cancer: A Retrospective Comparative Analysis

    SciTech Connect (OSTI)

    Akahane, Akio, E-mail: a.akahane@gmail.com; Sone, Miyuki; Ehara, Shigeru; Kato, Kenichi; Tanaka, Ryoichi; Nakasato, Tatsuhiko [Iwate Medical University School of Medicine, Department of Radiology (Japan)

    2011-12-15T23:59:59.000Z

    Purpose: This study was designed to compare central venous ports (CVP) from two different routes of venous access-the subclavian vein and arm vein-in terms of safety for patients with head and neck cancer (HNC). Methods: Patients with HNC who underwent image-guided implantations of CVPs were retrospectively evaluated. All CVPs were implanted under local anesthesia. Primary outcome measurements were rates and types of adverse events (AEs). Secondary outcomes included technical success and rate and reason of CVP removal. Results: A total of 162 patients (subclavian port group, 47; arm port group, 115) were included in this study. Technical success was achieved in all patients. The median follow-up period was 94 (range, 1-891) days. Two patients in the subclavian port group experienced periprocedural complications. Postprocedural AEs were observed in 8.5 and 22.6% of the subclavian port and arm port group patients, respectively (P = 0.044). Phlebitis and system occlusions were observed only in the arm port group. The rate of infection was not significantly different between the two groups. The CVP was removed in 34 and 39.1% of the subclavian port and arm port patients, respectively. Conclusions: Both subclavian and arm CVPs are feasible in patients with HNC. AEs were more frequent in the arm port group; thus, the arm port is not recommended as the first choice for patients with HNC. However, further experience is needed to improve the placement technique and the maintenance of CVPs and a prospective analysis is warranted.

  17. System and method for filling a plurality of isolated vehicle fluid circuits through a common fluid fill port

    SciTech Connect (OSTI)

    Sullivan, Scott C; Fansler, Douglas

    2014-10-14T23:59:59.000Z

    A vehicle having multiple isolated fluid circuits configured to be filled through a common fill port includes a first fluid circuit disposed within the vehicle, the first fluid circuit having a first fill port, a second fluid circuit disposed within the vehicle, and a conduit defining a fluid passageway between the first fluid circuit and second fluid circuit, the conduit including a valve. The valve is configured such that the first and second fluid circuits are fluidly coupled via the passageway when the valve is open, and are fluidly isolated when the valve is closed.

  18. Second Line of Defense, Port of Buenos Aires and Exolgan Container Terminal Operational Testing and Evaluation Plan, Buenos Aires, Argentina

    SciTech Connect (OSTI)

    Roberts, Bryan W.

    2012-08-23T23:59:59.000Z

    The Office of the Second Line of Defense (SLD) Megaports project team for Argentina will conduct operational testing and evaluation (OT&E) at Exolgan Container Terminal at the Port of Dock Sud from July 16-20, 2012; and at the Port of Buenos Aires from September 3-7, 2012. SLD is installing radiation detection equipment to screen export, import, and transshipment containers at these locations. The purpose of OT&E is to validate and baseline an operable system that meets the SLD mission and to ensure the system continues to perform as expected in an operational environment with Argentina Customs effectively adjudicating alarms.

  19. Weight Distribution of a Class of Binary Linear Block Codes Formed from RCPC Codes

    E-Print Network [OSTI]

    Shen, Yushi Dr.; Cosman, Pamela C; Milstein, Laurence B

    2006-01-01T23:59:59.000Z

    formed from convolutional codes,” IEEE Trans. Commun. , vol.terminated convolutional codes,” IEEE Trans. Inform. Theory,decoding of linear block codes and related soft- decision

  20. Introduction Space Time Codes Space Time Coding with Feedback New Thoughts Summary Space-Time Coding for Multi-Antenna

    E-Print Network [OSTI]

    Veeravalli, Venugopal

    Introduction Space Time Codes Space Time Coding with Feedback New Thoughts Summary Space 2007 #12;Introduction Space Time Codes Space Time Coding with Feedback New Thoughts Summary MIMO: Diversity vs Multiplexing Multiplexing Diversity Pictures taken from lectures notes on Space Time Coding