Powered by Deep Web Technologies
Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Automation i Distributionsnät; Distribution automation.  

E-Print Network [OSTI]

?? As a part of Göteborg Energi’s work towards a smarter electric grid, the company has chosen to investigate the possibilities of automation in their… (more)

Mård, Mathias

2012-01-01T23:59:59.000Z

2

Definition: Automated Distribution Circuit Switches | Open Energy  

Open Energy Info (EERE)

Circuit Switches Circuit Switches Jump to: navigation, search Dictionary.png Automated Distribution Circuit Switches Distribution circuit switches that can be operated automatically in response to control signals from local sensors, distribution automation systems, or grid control systems. Such switches can be installed as automated devices or existing equipment can be retrofitted with controls and communications. The degree of automation depends on the controls and communications system implemented. These switches can be opened or closed to isolate portions of a distribution circuit that has experienced a short circuit (fault), or must be taken out of service for maintenance or other operations. When used in combination, these switches can reroute power from other substations or nearby distribution circuits.[1]

3

E-Print Network 3.0 - automated test equipment Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

test equipment Search Powered by Explorit Topic List Advanced Search Sample search results for: automated test equipment Page: << < 1 2 3 4 5 > >> 1 Junior QA Engineer Intern...

4

A DISTRIBUTED AUTOMATION SYSTEM FOR ELECTROPHYSICAL INSTALLATIONS  

E-Print Network [OSTI]

A DISTRIBUTED AUTOMATION SYSTEM FOR ELECTROPHYSICAL INSTALLATIONS V.R. Kozak Budker Institute There was designed a set of devices for automation systems of physical installations. On this basis approach. KEY WORDS Automation, systems, applications, CANBUS, embedded, controller. 1. Introduction Budker

Kozak, Victor R.

5

Distributed Automated Demand Response - Energy Innovation Portal  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transmission Find More Like This Return to Search Distributed Automated Demand Response Lawrence Livermore National Laboratory Contact LLNL About This Technology...

6

Defect Prevention and Detection in Software for Automated Test Equipment  

SciTech Connect (OSTI)

Software for automated test equipment can be tedious and monotonous making it just as error-prone as other software. Active defect prevention and detection are also important for test applications. Incomplete or unclear requirements, a cryptic syntax used for some test applications—especially script-based test sets, variability in syntax or structure, and changing requirements are among the problems encountered in one tester. Such problems are common to all software but can be particularly problematic in test equipment software intended to test another product. Each of these issues increases the probability of error injection during test application development. This report describes a test application development tool designed to address these issues and others for a particular piece of test equipment. By addressing these problems in the development environment, the tool has powerful built-in defect prevention and detection capabilities. Regular expressions are widely used in the development tool as a means of formally defining test equipment requirements for the test application and verifying conformance to those requirements. A novel means of using regular expressions to perform range checking was developed. A reduction in rework and increased productivity are the results. These capabilities are described along with lessons learned and their applicability to other test equipment software. The test application development tool, or “application builder”, is known as the PT3800 AM Creation, Revision and Archiving Tool (PACRAT).

E. Bean

2006-11-30T23:59:59.000Z

7

Definition: Distribution Automation Communications Network | Open Energy  

Open Energy Info (EERE)

Automation Communications Network Automation Communications Network Jump to: navigation, search Dictionary.png Distribution Automation Communications Network A communications network or networks designed to deliver control signals and information between distribution automation devices, and between these devices and utility grid control systems. These networks can utilize wired or wireless connections, and can be utility-owned or provided as services by a third party.[1] Related Terms distribution automation References ↑ https://www.smartgrid.gov/category/technology/distribution_automation_communications_network [[C LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ategory: Smart Grid Definitionssmart grid,smart grid, |Template:BASEPAGENAME]]smart grid,smart grid, Retrieved from

8

LABORATORY EQUIPMENT Most of the work at the Automation and Control Institute is done with the  

E-Print Network [OSTI]

15 4 LABORATORY EQUIPMENT Most of the work at the Automation and Control Institute is done with MetsoDNA open automation system. When testing more sophisticated control algorithms the process data

9

Distributed Intelligent Automated Demand Response (DIADR) Building  

Broader source: Energy.gov (indexed) [DOE]

Distributed Intelligent Automated Demand Distributed Intelligent Automated Demand Response (DIADR) Building Management System Distributed Intelligent Automated Demand Response (DIADR) Building Management System The U.S. Department of Energy (DOE) is currently conducting research into distributed intelligent-automated demand response (DIADR) building management systems. Project Description This project aims to develop a DIADR building management system with intelligent optimization and control algorithms for demand management, taking into account a multitude of factors affecting cost including: Comfort Heating, ventilating, and air conditioning (HVAC) Lighting Other building systems Climate Usage and occupancy patterns. The key challenge is to provide the demand response the ability to address more and more complex building systems that include a variety of loads,

10

Definition: Distribution Automation | Open Energy Information  

Open Energy Info (EERE)

Automation Automation Jump to: navigation, search Dictionary.png Distribution Automation DA is a family of technologies including sensors, processors, communication networks, and switches that can perform a number of distribution system functions depending on how they are implemented. Over the last 20 years, utilities have been applying DA to improve reliability, service quality and operational efficiency. More recently, DA is being applied to perform automatic switching, reactive power compensation coordination, or other feeder operations/control.[1] Related Terms sustainability, smart grid References ↑ https://www.smartgrid.gov/category/technology/distribution_automation [[Ca LikeLike UnlikeLike You and one other like this.One person likes this. Sign Up to see what your friends like.

11

DAVIC - Distributed Energy Automation via Implicit Communication  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DAVIC - Distributed Energy Automation via Implicit Communication DAVIC - Distributed Energy Automation via Implicit Communication Speaker(s): Peter Palensky Date: January 22, 2008 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Peng Xu The electricity grid is seen as a wide-area distributed process, determined by its sub-processes - in our case the loads and distributed generation. Network-based coordination needs to be done very carefully and properly timed to avoid instabilities. Luckily, every point of the grid has the same grid frequency and the same time. Integrating these two trivial things (implicit communication) into one consistent communication model might complement a low-quality (explicit) best-effort communication channel (e.g. Internet, GPRS) for real time applications. A simulation shall clarify how

12

Improving reuse of semiconductor equipment through benchmarking, standardization, and automation  

E-Print Network [OSTI]

The 6D program at Intel® Corporation was set up to improve operations around capital equipment reuse, primarily in their semiconductor manufacturing facilities. The company was faced with a number of challenges, including ...

Silber, Jacob B. (Jacob Bradley)

2006-01-01T23:59:59.000Z

13

A Distributed Facilities Automation System For IBM Buildings  

E-Print Network [OSTI]

protocol. This will allow the facility manager to take advantage of the expertise of ~any control system suppliers while retaining central control, override authority, and specialized manage ment functions. A distributed facilities automation system... protocol. This will allow the facility manager to take advantage of the expertise of ~any control system suppliers while retaining central control, override authority, and specialized manage ment functions. A distributed facilities automation system...

Houle, W. D. Sr.

14

Integrated, Automated Distributed Generation Technologies Demonstration  

SciTech Connect (OSTI)

The purpose of the NETL Project was to develop a diverse combination of distributed renewable generation technologies and controls and demonstrate how the renewable generation could help manage substation peak demand at the ATK Promontory plant site. The Promontory plant site is located in the northwestern Utah desert approximately 25 miles west of Brigham City, Utah. The plant encompasses 20,000 acres and has over 500 buildings. The ATK Promontory plant primarily manufactures solid propellant rocket motors for both commercial and government launch systems. The original project objectives focused on distributed generation; a 100 kW (kilowatt) wind turbine, a 100 kW new technology waste heat generation unit, a 500 kW energy storage system, and an intelligent system-wide automation system to monitor and control the renewable energy devices then release the stored energy during the peak demand time. The original goal was to reduce peak demand from the electrical utility company, Rocky Mountain Power (RMP), by 3.4%. For a period of time we also sought to integrate our energy storage requirements with a flywheel storage system (500 kW) proposed for the Promontory/RMP Substation. Ultimately the flywheel storage system could not meet our project timetable, so the storage requirement was switched to a battery storage system (300 kW.) A secondary objective was to design/install a bi-directional customer/utility gateway application for real-time visibility and communications between RMP, and ATK. This objective was not achieved because of technical issues with RMP, ATK Information Technology Department’s stringent requirements based on being a rocket motor manufacturing facility, and budget constraints. Of the original objectives, the following were achieved: • Installation of a 100 kW wind turbine. • Installation of a 300 kW battery storage system. • Integrated control system installed to offset electrical demand by releasing stored energy from renewable sources during peak hours of the day. Control system also monitors the wind turbine and battery storage system health, power output, and issues critical alarms. Of the original objectives, the following were not achieved: • 100 kW new technology waste heat generation unit. • Bi-directional customer/utility gateway for real time visibility and communications between RMP and ATK. • 3.4% reduction in peak demand. 1.7% reduction in peak demand was realized instead.

Jensen, Kevin

2014-09-30T23:59:59.000Z

15

A new highly automated sputter equipment for in situ investigation of deposition processes with synchrotron radiation  

SciTech Connect (OSTI)

HASE (Highly Automated Sputter Equipment) is a new mobile setup developed to investigate deposition processes with synchrotron radiation. HASE is based on an ultra-high vacuum sputter deposition chamber equipped with an in-vacuum sample pick-and-place robot. This enables a fast and reliable sample change without breaking the vacuum conditions and helps to save valuable measurement time, which is required for experiments at synchrotron sources like PETRA III at DESY. An advantageous arrangement of several sputter guns, mounted on a rotative flange, gives the possibility to sputter under different deposition angles or to sputter different materials on the same substrate. The chamber is also equipped with a modular sample stage, which allows for the integration of different sample environments, such as a sample heating and cooling device. The design of HASE is unique in the flexibility. The combination of several different sputtering methods like standard deposition, glancing angle deposition, and high pressure sputter deposition combined with heating and cooling possibil-ities of the sample, the large exit windows, and the degree of automation facilitate many different grazing incidence X-ray scattering experiments, such as grazing incidence small and wide angle X-ray scattering, in one setup. In this paper we describe in detail the design and the performance of the new equipment and present the installation of the HASE apparatus at the Micro and Nano focus X-ray Scattering beamline (MiNaXS) at PETRA III. Furthermore, we describe the measurement options and present some selected results. The HASE setup has been successfully commissioned and is now available for users.

Doehrmann, Ralph; Botta, Stephan; Buffet, Adeline; Santoro, Gonzalo; Schlage, Kai; Schwartzkopf, Matthias; Risch, Johannes F. H.; Mannweiler, Roman; Roth, Stephan V. [DESY, Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22607 Hamburg (Germany); Bommel, Sebastian [DESY, Deutsches Elektronen-Synchrotron, Notkestrasse 85, D-22607 Hamburg (Germany); Institut fuer Physik, Humboldt-Universitaet zu Berlin, Newtonstr. 15, D-12489 Berlin (Germany); Brunner, Simon; Metwalli, Ezzeldin; Mueller-Buschbaum, Peter [Lehrstuhl fuer Funktionelle Materialien, Physik-Department, Technische Universitaet Muenchen, James-Franck-Str. 1, D-85748 Garching (Germany)

2013-04-15T23:59:59.000Z

16

DA (Distribution Automation) (Smart Grid Project) | Open Energy Information  

Open Energy Info (EERE)

DA (Distribution Automation) (Smart Grid Project) DA (Distribution Automation) (Smart Grid Project) Jump to: navigation, search Project Name DA (Distribution Automation) Country Netherlands Coordinates 52.132633°, 5.291266° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":52.132633,"lon":5.291266,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

17

ETM (Distribution Network Automation on 10 kV cable line stations...  

Open Energy Info (EERE)

ETM (Distribution Network Automation on 10 kV cable line stations) (Smart Grid Project) Jump to: navigation, search Project Name ETM (Distribution Network Automation on 10 kV cable...

18

Distribution Effectiveness and Impacts on Equipment Sizing for Residential Thermal Distribution Systems  

E-Print Network [OSTI]

1 LBNL-43724 Distribution Effectiveness and Impacts on Equipment Sizing for Residential Thermal Distribution Systems Walker, I., Sherman, M., and Siegel, J. Environmental Energy Technologies Division Energy .................................................................................................................. 14 Figure 1. Simulations of Pulldowns from 3:00 p.m. on a Sacramento Design Day

19

Distribution capacitor automation that controls voltage and saves energy  

SciTech Connect (OSTI)

The Electric Distribution Business Line of Southern California Edison Company (SCE) has begun a program to improve the distribution system operations and electrical efficiency. The program, called the Distribution System Efficiency Enhancement Program (DSEEP), consists of five principal projects: Automated Switching, Circuit Lock-Out Alarming, Substation Monitoring and Control, Outage Management, and Distribution Capacitor Automation Project (DCAP). DCAP is the largest and most sophisticated of the projects being implemented. The project takes advantage of fine-tuning customer voltages for conservation voltage regulation (CVR) benefits as well as minimizes line losses by reducing unnecessary reactive power flow. DCAP can also help to increase transmission line and substation capacity by improving system power factor. The DCAP system takes advantage of the distributed processing capability of meters, capacitor controllers, radios, and substation processors. DCAP uses two-way packet radios and new electronic meters that read real-time customer voltages as well as energy consumption. The radios transmit customer meter voltage information and capacitor status to substation processors, where a control algorithm runs to determine which capacitors should be turned on or off. The objective of DCAP is to reduce over-all net energy transfer from the substation to the customer and meet system VAR requirements. SCE has tested the system on 66 circuit capacitors (including 3 substation capacitors) on 18 circuits served from two substations. The positive results of the DCAP demonstrations has led to an aggressive roll-out plan for system-wide implementation of automating over 7600 switched capacitors by year-end 1995.

Williams, B.R.

1994-12-31T23:59:59.000Z

20

Equipment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Facility: Building 382 Rev. 1, 02/11/00 Facility: Building 382 Rev. 1, 02/11/00 Training: (1) ESH114 Lockout/Tagout ASD125 APS LOTO ESH371 Electrical Safety - General ESH195 PPE ESH141 Hand and Power Tools (2) ESH707 Accelerator Worker ESH738 GERT (3) ESH196 Hazard Communication ESH376 or 456 Chemical Waste (4) ASDSF6 (5) ESH170 OSHA Lead Standard ESH196 Hazard Communication ESH195 PPE ESH141 Hand and Power Tools (6) ESH195 PPE ESH141 Hand and Power Tools (7) Informal OJT (8) Formal OJT Management Tools: (A) ANL-E ESH Manual SMART (B) APS-SAD APS-CO (C) Waste Handling Procedure Manual Equipment Hazards Engineered Controls Electrical Safety Training References Electrical Safety Procedures Mechanical Safety Training References Mechanical

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Powerline Communication System for Monitoring and Supervision of Feeder Equipments for MV Substation Automation  

E-Print Network [OSTI]

Substation Automation LiPing LU1,2 , GangYan LI1 , YeQiong SONG2 1 ­ School of Mechanical and Electronical With the deregulation of power market and for providing better services to electric consumers, the current substation into the substations by the utilities to integrate data from relays and Intelligent Electronic Devices (IEDs

Paris-Sud XI, Université de

22

Design Concepts for Power Distribution Equipment Serving Non-Linear Loads  

E-Print Network [OSTI]

This paper explores the effects of power system harmonics induced by non-sinusoidal loads on electrical distribution equipment. The first portion examines the harmonic phenomenon to more fully understand harmonic current behavior from an intuitive...

Massey, G. W.

23

Life cycle assessment of electricity transmission and distribution—part 2: transformers and substation equipment  

Science Journals Connector (OSTI)

The purpose of this paper is to characterize the environmental impacts of equipment used in power transmission and distribution. This study is divided in two parts, each addressing different main components of th...

Raquel Santos Jorge; Troy R. Hawkins…

2012-02-01T23:59:59.000Z

24

Process Development Automation:? An Evolutionary Approach  

Science Journals Connector (OSTI)

Process Development Automation:? An Evolutionary Approach ... In contrast, standard laboratory equipment already contains some automated capabilities but is normally unused in our automation strategies. ... What Can Be Automated? ...

Mike Pollard

2001-04-27T23:59:59.000Z

25

Scalable Distributed Automation System: Scalable Real-time Decentralized Volt/VAR Control  

SciTech Connect (OSTI)

GENI Project: Caltech is developing a distributed automation system that allows distributed generators—solar panels, wind farms, thermal co-generation systems—to effectively manage their own power. To date, the main stumbling block for distributed automation systems has been the inability to develop software that can handle more than 100,000 distributed generators and be implemented in real time. Caltech’s software could allow millions of generators to self-manage through local sensing, computation, and communication. Taken together, localized algorithms can support certain global objectives, such as maintaining the balance of energy supply and demand, regulating voltage and frequency, and minimizing cost. An automated, grid-wide power control system would ease the integration of renewable energy sources like solar power into the grid by quickly transmitting power when it is created, eliminating the energy loss associated with the lack of renewable energy storage capacity of the grid.

None

2012-03-01T23:59:59.000Z

26

Complete Automation of Future Grid for Optimal Real-Time Distribution of Renewables  

E-Print Network [OSTI]

Complete Automation of Future Grid for Optimal Real-Time Distribution of Renewables Kiyoshi integrates tie-set graph theory with an intelligent agent system, is presented to distribute renewable energy and renewable generation is highly variable and unpredictable. Simulation results on a one hundred-node network

Loudon, Catherine

27

A Fully Automated Fault-tolerant System for Distributed Video Processing and Off-site Replication  

E-Print Network [OSTI]

A Fully Automated Fault-tolerant System for Distributed Video Processing and Off-site Replication been a failure-prone tedious operation with an operator needed to babysit the processing and off-site, off-site replication, fault-tolerance, grid, educational research. 1. INTRODUCTION In different fields

Wisconsin at Madison, University of

28

Automated Analysis of Fault-Tolerance in Distributed Systems Scott D. Stoller y  

E-Print Network [OSTI]

Automated Analysis of Fault-Tolerance in Distributed Systems #3; Scott D. Stoller y Computer satisfy in speci#12;ed failure scenarios. Our analysis method is to compute, for each failure scenario for which the user speci#12;ed a fault-tolerance requirement, an MFG representing the system's communication

Schneider, Fred B.

29

Abstract--Implementation of Distribution Automation (DA) and Demand Side Management (DSM) intended to serve both  

E-Print Network [OSTI]

Abstract--Implementation of Distribution Automation (DA) and Demand Side Management (DSM) intended, requires a wide-area two-way communication system. DA and DSM devices (customer meters, switches, etc for both DA/DSM applications can be met. And a scheduling policy is proposed to provide the applications

Paris-Sud XI, Université de

30

Automated Distributed Implementation of Component-based Models with Priorities  

E-Print Network [OSTI]

School of Computer Science University of Waterloo 200 University Avenue West Waterloo, Canada, N2L3G1.4 [Computer-Communication Networks]: Distributed Systems[Distributed applications] ; D.1.3 [Programming the European Community's Seventh Framework Pro- gramme [FP7/2007-2013] under grant agreement no 248776 (PRO3D

Paris-Sud XI, Université de

31

Review of automated custody transfer equipment for large-volume gas flow measurement. Final report, August 1, 1987-February 28, 1988  

SciTech Connect (OSTI)

The influence of electronic automation on the accuracy of gas custody transfer measurements was investigated. The term Electronic Flow Measurement (EFM) denotes both electronic flow correctors (for positive displacement meters) and flow computers (for orifice plate measurements). Electronic devices have potential to be slightly more accurate than their mechanical counterparts. Electronic systems have the additional benefits of greater application flexibility, reduced flow corrector inventory, reduced maintenance and calibration requirements, and data storage and communication capability. The primary concerns with EFM equipment are compatibility between units made by different manufacturers and their ability to function under extreme environmental conditions.

Rush, W.F.; Tamosaitis, V.

1989-06-01T23:59:59.000Z

32

ETM (Distribution Network Automation on 10 kV cable line stations) (Smart  

Open Energy Info (EERE)

ETM (Distribution Network Automation on 10 kV cable line stations) (Smart ETM (Distribution Network Automation on 10 kV cable line stations) (Smart Grid Project) Jump to: navigation, search Project Name ETM (Distribution Network Automation on 10 kV cable line stations) Country Hungary Headquarters Location Budapest, Hungary Coordinates 47.498405°, 19.040758° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":47.498405,"lon":19.040758,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

33

Home Automation Using Elvin.  

E-Print Network [OSTI]

?? Home automation systems of today tend to be external solutions to an existing product that enable rather complex and expensive communications equipment to be… (more)

Malm, Anders

2005-01-01T23:59:59.000Z

34

Test Automation Test Automation  

E-Print Network [OSTI]

Test Automation Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2013 Mousavi: Test Automation #12;Test Automation Outline Test Automation Mousavi: Test Automation #12;Test Automation Why? Challenges of Manual Testing Test-case design: Choosing inputs

Mousavi, Mohammad

35

Architecting global automation systems over a distributed multi-agent infrastructure  

Science Journals Connector (OSTI)

In this work we present an agent-based architecture for Global Automation Systems. The architecture follows a layered abstract model that allows decoupling design responsibilities, promotes high cohesion within layers and clearly emphasizes the environment. ...

Franco Guidi-Polanco; Claudio Cubillos; Giuseppe Menga

2005-06-01T23:59:59.000Z

36

Coordination of a distribution level continuously controlled compensation device with existing substation equipment for long term VAR management  

SciTech Connect (OSTI)

The implementation of a continuously controlled reactive compensation device, such as an SVC or a static condenser'' (STATCON), in a distribution-level substation provides opportunities to improve power quality and reliability due to the speed of response of such a device. Further benefits can be gained by coordinating the reactive compensation device and its related controls with other substation voltage control equipment, such as load tap changing (LTC) transformers and mechanically-switched capacitors. The results presented in this paper illustrate the impact that a [+-] 12 Mvar STATCON can have on a 150 MW, 12.5 kV load bus, in the Commonwealth Edison power system. Three control concepts for various levels of integration of the substation STATCON, LTCs, and mechanically-switched capacitors are presented. With broader application of SVCs and STATCONs at distribution substations, various other control strategies may also evolve.

Paserba, J.J.; Leonard, D.J.; Miller, N.W. (GE Industrial and Power Systems, Schenectady, NY (United States). Power Systems Engineering Dept.); Lauby, M.G. (Electric Power Research Inst., Palo Alto, CA (United States)); Naumann, S.T. (Commonwealth Edison Co., Chicago, IL (United States)); Sener, F.P. (PHE Consulting, Brecksville, OH (United States))

1994-04-01T23:59:59.000Z

37

Hybrid Control Network Intrusion Detection Systems for Automated Power Distribution Systems  

E-Print Network [OSTI]

and improve the reliability of the distribution system [3].distribution topology for protection and to improve reliability.

Parvania, Masood; Koutsandria, Georgia; Muthukumar, Vishak; Peisert, Sean; McParland, Chuck; Scaglione, Anna

2014-01-01T23:59:59.000Z

38

Disciplined agility for process control & automation  

E-Print Network [OSTI]

Process automation vendors must consider agility as a basis to gain a competitive edge in innovation. Process Automation systems can impact the operating cost of manufacturing equipment, the safe control of large quantities ...

Tibazarwa, Augustine

2009-01-01T23:59:59.000Z

39

Substation automation gains momentum with modern options  

SciTech Connect (OSTI)

This paper discusses issues associated with utility substation automation. Monitoring equipment for monitoring power flow, quality, and harmonics for three substations simultaneously is described.

Beaty, W.

1996-12-01T23:59:59.000Z

40

Survivability models for the assessment of smart grid distribution automation network designs  

Science Journals Connector (OSTI)

Smart grids are fostering a paradigm shift in the realm of power distribution systems. Whereas traditionally different components of the power distribution system have been provided and analyzed by different teams through different lenses, smart grids ... Keywords: fault tolerance, smart grid, survivability, transient analysis

Alberto Avritzer; Sindhu Suresh; Daniel Sadoc Menasché; Rosa Maria Meri Leão; Edmundo de Souza e Silva; Morganna Carmem Diniz; Kishor Trivedi; Lucia Happe; Anne Koziolek

2013-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Reliability Improvements from the Application of Distribution Automation Technologies - Initial Results  

Broader source: Energy.gov (indexed) [DOE]

U.S. Department of Energy | December 2012 Table of Contents Executive Summary ................................................................................................................. ii 1. Introduction ..................................................................................................................... 1 1.1 Purpose and Scope ....................................................................................................... 1 1.2 Background on Electric Distribution Reliability ............................................................ 2 1.3 Organization of this Report .......................................................................................... 3 2. Overview of Systems, Devices, and Expected Benefits...................................................... 4

42

Automated Data Collection for Determining Statistical Distributions of Module Power Undergoing Potential-Induced Degradation: Preprint  

SciTech Connect (OSTI)

We propose a method for increasing the frequency of data collection and reducing the time and cost of accelerated lifetime testing of photovoltaic modules undergoing potential-induced degradation (PID). This consists of in-situ measurements of dark current-voltage curves of the modules at elevated stress temperature, their use to determine the maximum power at 25 degrees C standard test conditions (STC), and distribution statistics for determining degradation rates as a function of stress level. The semi-continuous data obtained by this method clearly show degradation curves of the maximum power, including an incubation phase, rates and extent of degradation, precise time to failure, and partial recovery. Stress tests were performed on crystalline silicon modules at 85% relative humidity and 60 degrees C, 72 degrees C, and 85 degrees C. Activation energy for the mean time to failure (1% relative) of 0.85 eV was determined and a mean time to failure of 8,000 h at 25 degrees C and 85% relative humidity is predicted. No clear trend in maximum degradation as a function of stress temperature was observed.

Hacke, P.; Spataru, S.

2014-08-01T23:59:59.000Z

43

Cleanroom Equipment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Conventional Machining Engis Lapping and Polishing Machine MET One particle Counter Sand Blaster Cabinet Flycutting Machine Lithography Equipment Mann 600 Pattern Generator Oriel...

44

Automated Surface Observing System: Standby Power Options  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Automated Automated Surface Observing System Standby Options Power Automated Surface Observing System (ASOS) General System Description * Self contained group of sensors and data gathering equipment that produces an automated weather observation * Weather observations support aviation, climate data, non government weather operations, public consumption, etc. * Initial deployment began in 1991 and continued through 1997 * Located at 884 sites nationwide, normally at airports * System has two distinct subsystems: Field installed equipment (DCP & Sensor Group) and an indoor processor (ACU) with peripherals * Separate facility power for DCP & Sensors and ACU 1 * measure and collect data * Located on the airport * back up group for 10 minutes * Currently pl

45

IEEE TRANS. AUTOM. CONTROL, SPECIAL ISSUE ON WIRELESS SENSOR AND ACTUATOR NETWORKS 1 Energy Optimized Topologies for Distributed  

E-Print Network [OSTI]

. We formulate the combinatorial optimization problem of selecting such a minimal energy tree that yield energy efficient bidirectional span- ning trees and establish associated bounds on the optimalIEEE TRANS. AUTOM. CONTROL, SPECIAL ISSUE ON WIRELESS SENSOR AND ACTUATOR NETWORKS 1 Energy

46

Automation Status  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

NREL Manufacturing R&D Workshop NREL Manufacturing R&D Workshop NREL H2/FC Manufacturing R&D Workshop Automation Status Garry Sperrick garry@sperkllc.com 585-259-0311 August 11, 2011 Automation Status NREL Manufacturing R&D Workshop Presentation Overview ƒ Brief Introduction ƒ DOE / NREL - Review & Discussion ƒ Automation Platforms ƒ Automation Processes ƒ Automation Considerations of the Manufacturer ƒ Manufacturer and the Supplier ƒ Three (3) Automation Programs Following these Guidelines ƒ Automotive Component Manufacturing ƒ Medical Manufacturing ƒ Membrane Electrode Assembly Manufacturing ƒ Hypothetical Fuel Cell Manufacturing Platforms August 11, 2011 Automation Status NREL Manufacturing R&D Workshop Professional Bio ƒ Automation Technician - Mobil Chemical

47

Home Automation  

E-Print Network [OSTI]

In this paper I briefly discuss the importance of home automation system. Going in to the details I briefly present a real time designed and implemented software and hardware oriented house automation research project, capable of automating house's electricity and providing a security system to detect the presence of unexpected behavior.

Ahmed, Zeeshan

2010-01-01T23:59:59.000Z

48

Test Automation Ant JUnit Test Automation  

E-Print Network [OSTI]

Test Automation Ant JUnit Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2012 Mousavi: Test Automation #12;Test Automation Ant JUnit Outline Test Automation Ant JUnit Mousavi: Test Automation #12;Test Automation Ant JUnit Why? Challenges of Manual Testing

Mousavi, Mohammad

49

Atlas Sodium Automated Batch Synthesis System  

E-Print Network [OSTI]

Atlas Sodium Automated Batch Synthesis System (Syrris) June 2013 #12;Introduction to the system · The Atlas Sodium system consists of an Atlas base equipped with a 400ºC hotplate, a stacking dry bath systemL) for automated addition and/or removal of solution. · The system is computer controlled by the Atlas software

Subramanian, Venkat

50

Energy Automation Systems Inc | Open Energy Information  

Open Energy Info (EERE)

Energy Automation Systems Inc Energy Automation Systems Inc Jump to: navigation, search Name Energy Automation Systems Inc. Place Hendersonville, Tennessee Zip 37075 Sector Buildings, Efficiency Product An energy efficiency consultancy firm focusing on analysis of energy consumption in buildings and providing improvments in the efficiency of the distribution system and equipment loads, similar to an ESCO. Coordinates 36.304861°, -86.620214° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":36.304861,"lon":-86.620214,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

51

Validity of automated x-ray photoelectron spectroscopy algorithm to determine the amount of substance and the depth distribution of atoms  

Science Journals Connector (OSTI)

The author reports a systematic study of the range of validity of a previously developed algorithm for automated x-ray photoelectron spectroscopy analysis which takes into account the variation in both peak intensity and the intensity in the background of inelastically scattered electrons. This test was done by first simulating spectra for the Au4d peak with gold atoms distributed in the form of a wide range of nanostructures which includes overlayers with varying thickness a 5?Å layer of atoms buried at varying depths and a substrate covered with an overlayer of varying thickness. Next the algorithm was applied to analyze these spectra. The algorithm determines the number of atoms within the outermost 3 ? of the surface. This amount of substance is denoted AOS 3 ? (where ?   is the electron inelastic mean free path). In general the determined AOS 3 ? is found to be accurate to within ?10–20% depending on the depth distribution of the atoms. The algorithm also determines a characteristic length L which was found to give unambiguous information on the depth distribution of the atoms for practically all studied cases. A set of rules for this parameter which relates the value of L to the depths where the atoms are distributed was tested and these rules were found to be generally valid with only a few exceptions. The results were found to be rather independent of the spectral energy range (from 20 to 40?eV below the peak energy) used in the analysis.

Sven Tougaard

2013-01-01T23:59:59.000Z

52

A post-occupancy monitored evaluation of the dimmable lighting, automated shading, and underfloor air distribution system in The New York Times Building  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

23E 23E A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building E.S. Lee, L.L. Fernandes, B. Coffey, A. McNeil, R. Clear Lawrence Berkeley National Laboratory T. Webster, F. Bauman, D. Dickerhoff, D. Heinzerling, T. Hoyt University of California Berkeley Windows and Envelope Materials Group Building Technology and Urban Systems Department Environmental Energy Technologies Division January 2013 ! 2 Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any warranty,

53

EQUIPMENT NEWS  

Science Journals Connector (OSTI)

...techniques with computer science technologies in data acquisition, data...the latest communications technologies for real-time data transport...environmental data via an Intranet/Internet connection. This...techniques with computer science technologies in distributing process...

54

DOE-STD-1044-93 CN-1; Guide to Good Practices for Equipment and...  

Office of Environmental Management (EM)

distribution and lighting panels C Emergency equipment (fire alarm stations, eye wash stations, etc.) C Equipment components (motors, valves, pumps, etc.) C Equipment...

55

Laboratory Equipment Donation Program - Equipment Applications  

Office of Scientific and Technical Information (OSTI)

Specific questions concerning equipment should be directed to the point of Specific questions concerning equipment should be directed to the point of contact responsible for the item(s) under consideration. This information is listed on the "Equipment Information" page, as well as on the grant award e-mail sent to the applicant. Step 1: Search and Apply for Equipment Note: If you know the Item Control Number of the equipment you need, you may go directly to the on-line application. Please follow these procedures to "Search Equipment" and apply for equipment using the LEDP Online Application: Select the "Search Equipment" menu link. Enter the type of equipment desired into the search box or choose the "Equipment List" link, which will allow you see a complete list of available equipment. Select the "Item Control Number" for the desired equipment. This

56

Highway Electrification And Automation  

E-Print Network [OSTI]

Electrification and Automation Technologies - RegionalHighway Electrification and Automation Steven E. Shladovertechnology of highway automation,” as well as its belief

Shladover, Steven E.

1992-01-01T23:59:59.000Z

57

Petri Net Based Research of Home Automation Communication Protocol  

Science Journals Connector (OSTI)

The popularity of home automation has been increasing greatly in recent years. ... distributed, uncertain or randomized protocol model) of home automation, many questions concerned. For instance, is ... net to de...

Guangxuan Chen; Yanhui Du; Panke Qin; Jin Du…

2013-01-01T23:59:59.000Z

58

Solar Automation Inc | Open Energy Information  

Open Energy Info (EERE)

Inc Inc Jump to: navigation, search Name Solar Automation Inc Place Albuquerque, New Mexico Zip NM 8110 Product Produces manufacturing equipment for PV cells. References Solar Automation Inc[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Solar Automation Inc is a company located in Albuquerque, New Mexico . References ↑ "Solar Automation Inc" Retrieved from "http://en.openei.org/w/index.php?title=Solar_Automation_Inc&oldid=351247" Categories: Clean Energy Organizations Companies Organizations Stubs What links here Related changes Special pages Printable version Permanent link Browse properties About us Disclaimers Energy blogs Linked Data Developer services

59

Automated Store Management For Drum Storage Facility  

SciTech Connect (OSTI)

This paper describes advanced system technology developed for a new Drum Storage Facility to be operated by Taiwan Power Company (TPC). A logistics management concept is applied for the storage of solid rad-wastes in terms of automated handling, transportation and storing as well as in terms of data management. The individual equipments, such as automated Bridge Cranes, Automatic Guided Vehicles and auxiliary systems are introduced in this paper and the store management process is outlined. The authors report furthermore on challenges during the design and engineering phase and review the project implementation from the equipment supplier's end. (authors)

Koller, W.; Lang, R. [Siempelkamp Nukleartechnik GmbH, Krefeld (Germany)

2008-07-01T23:59:59.000Z

60

User Electrical Equipment Inspections  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

User Electronic and Electrical Equipment Inspection Criteria In order to be in compliance with NEC, OSHA, and DOE regulations all electronic and electrical equipment at the APS...

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Operations and Maintenance for Major Equipment Types | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

for Major Equipment Types for Major Equipment Types Operations and Maintenance for Major Equipment Types October 7, 2013 - 9:53am Addthis Equipment lies at the heart of all operations and maintenance (O&M) activities. This equipment varies greatly across the Federal sector in age, size, type, model, condition, etc. No single resource covers all equipment in use by Federal agencies, and listing major equipment types is beyond the scope of this website. Instead, the Federal Energy Management Program (FEMP) outlines major equipment types within chapter 9 of the Federal Energy Management Programs's (FEMP) O&M Best Practices Guide. The FEMP O&M Best Practices Guide focuses on: Boilers Steam traps Chillers Cooling towers Energy management and building automation systems Air handling systems

62

Energy Sub-Metering Equipment and Applications  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Sub-Metering Equipment and Applications Energy Sub-Metering Equipment and Applications Speaker(s): Sim Gurewitz Date: July 24, 2008 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Paul Mathew This talk will address the following topics:Submetering basics: What is it? How does a submeter work?How to obtain a finer level of energy information within the buildingApplications: Who submeters and why?LEED NC/EB/CS and submetering / Energy & Atmosphere pointsSubmetering equipment: gas, electric, water, steam, CW Btu and HHW BtuHow to install equipment without scheduling an outageLoad Control option for automated load shedding and peak shavingWireless submeters and communication options / integration to EMS-BMCSAutomatic remote meter reading and cost allocation softwarePutting it all together into a metering SYSTEM: read from anywhere, IP

63

Commercial Equipment Testing Enforcement Policies  

Broader source: Energy.gov [DOE]

In an exercise of its enforcement discretion, under specific conditions, DOE will not perform assessment testing, verification testing, or enforcement testing on units of certain types of commercial equipment if the manufacturer distributes in commerce an otherwise identical unit that does not have that feature.

64

University of Delaware | CCEI Equipment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

CCEI Equipment Click column headings to sort Type Equipment Details Institution Type Equipment Details Institution: Lab Lab BACK TO TOP...

65

Automation Performance Index.  

E-Print Network [OSTI]

??Automation is intended to improve overall building performance. Building Automation Systems (BAS) are attractive and popular due to their promise of increased operational effectiveness. BAS… (more)

Makarechi, Shariar

2006-01-01T23:59:59.000Z

66

Views on Automation  

Science Journals Connector (OSTI)

Views on Automation ... Industrial managements, he feels, must allay workers' fears by showing how they can take pride in the greater accomplishment of automated plants. ...

1957-07-29T23:59:59.000Z

67

Computer aids for electronic equipment design — 21 years on  

Science Journals Connector (OSTI)

In 1968, Eric Wolfendale wrote an article entitled ‘Computer aids for electronic equipment design’ in the first issue of Computer-Aided Design. At the time Wolfendale led a team within Racal Research Ltd that was investigating the possibilities for automating aspects of the process of designing electronic equipment. In the intervening twenty years, Wolfendale's research team has transformed itself into a supplier of electronic design automation (EDA) systems, the Racal Redac Group. Reading Wolfendale's article now is an enlightening task, because it reveals that while substantial progress has been made in developing software to support EDA, the pioneers in the field had clearly identified most, if not all, of the major issues.

R. Barrett

1989-01-01T23:59:59.000Z

68

Agricultural Equipment | Open Energy Information  

Open Energy Info (EERE)

Equipment Incentives Retrieved from "http:en.openei.orgwindex.php?titleAgriculturalEquipment&oldid267143...

69

Mirle Automation Corporation | Open Energy Information  

Open Energy Info (EERE)

Mirle Automation Corporation Mirle Automation Corporation Jump to: navigation, search Name Mirle Automation Corporation Place Hsinchu, Taiwan Zip 30077 Sector Solar Product A Taiwan-based automation system integrators and related product manufacturers who have entered thin film solar cell manufacturing equipment business. Coordinates 24.69389°, 121.148064° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":24.69389,"lon":121.148064,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

70

Energy Audit Equipment  

E-Print Network [OSTI]

The tools (equipment) needed to perform an energy audit include those items which assist the auditor in measuring the energy used by equipment or lost in inefficiency. Each tool is designed for a specific measurement. They can be inexpensive simple...

Phillips, J.

2012-01-01T23:59:59.000Z

71

Automated Demand Response and Commissioning  

SciTech Connect (OSTI)

This paper describes the results from the second season of research to develop and evaluate the performance of new Automated Demand Response (Auto-DR) hardware and software technology in large facilities. Demand Response (DR) is a set of activities to reduce or shift electricity use to improve the electric grid reliability and manage electricity costs. Fully-Automated Demand Response does not involve human intervention, but is initiated at a home, building, or facility through receipt of an external communications signal. We refer to this as Auto-DR. The evaluation of the control and communications must be properly configured and pass through a set of test stages: Readiness, Approval, Price Client/Price Server Communication, Internet Gateway/Internet Relay Communication, Control of Equipment, and DR Shed Effectiveness. New commissioning tests are needed for such systems to improve connecting demand responsive building systems to the electric grid demand response systems.

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Bourassa, Norman

2005-04-01T23:59:59.000Z

72

Property Tax Assessment for Renewable Energy Equipment | Department of  

Broader source: Energy.gov (indexed) [DOE]

Property Tax Assessment for Renewable Energy Equipment Property Tax Assessment for Renewable Energy Equipment Property Tax Assessment for Renewable Energy Equipment < Back Eligibility Utility Savings Category Bioenergy Water Buying & Making Electricity Solar Wind Program Info State Arizona Program Type Property Tax Incentive Rebate Amount Renewable-energy equipment assessed at 20% of its depreciated cost Provider Arizona Department of Revenue Renewable energy equipment owned by utilities and other entities operating in Arizona is assessed at 20% of its depreciated cost for the purpose of determining property tax. "Renewable energy equipment" is defined as "electric generation facilities, electric transmission, electric distribution, gas distribution or combination gas and electric transmission

73

Laboratory Equipment Donation Program - Equipment List  

Office of Scientific and Technical Information (OSTI)

Equipment List Equipment List Already know the item control number? Submit Reset Item Control Number Equipment Name Date Entered Condition Picture 89022833290004 1300594 TLD DETECTOR 12/16/2013 Repairable N/A 89022833290005 1300595 PICOMETER 12/16/2013 Repairable N/A 89022833290008 1300598 READER 12/16/2013 Repairable N/A 89022833290010 1300600 DETECTOR VACUUM PUMP 12/16/2013 Repairable N/A 89022833290016 1300606 TLD READER 12/16/2013 Repairable N/A 89022833290018 1300608 READER 12/16/2013 Repairable N/A 89022833290019 1300609 ANALYZER WITH DETECTOR 12/16/2013 Repairable N/A 89022833180013 1300993 PRESSURE REGULATOR 12/04/2013 Repairable N/A 89022833180022 1301098 VACUUM GAUGE 12/04/2013 Repairable N/A 89022833180023 1301099 OSCILLOSCOPE 12/04/2013 Repairable N/A

74

Beyond Commissioning: The Role of Automation  

SciTech Connect (OSTI)

This article takes a brief look at the benefits of commissioning and describes a vision of the future where most of the objectives of commissioning will be accomplished automatically by capabilities built into the building systems themselves. Commissioning will become an activity that's performed continuously rather than periodically, and only repairs requiring replacement or overhaul of equipment will require manual intervention. The article then identifies some of the technologies that will be needed to realize this vision and ends with a call for all involved in the enterprise of building commissioning and automation to embrace and dedicate themselves to a future of automated commissioning.

Brambley, Michael R.; Katipamula, Srinivas

2005-02-01T23:59:59.000Z

75

Electric Vehicle Supply Equipment  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Procurement of Electric Vehicle Supply Equipment This Guidance provides a description of the types of requirements to be included in an employer's workplace charging request for...

76

Renewable Energy Equipment Exemption  

Broader source: Energy.gov [DOE]

Iowa allow a sales tax exemption for solar, wind, and hydroelectricity equipment. As of May 2013, the Iowa sales tax rate is 6%.

77

Maersk Line Equipment guide  

National Nuclear Security Administration (NNSA)

a total capacity of 85 cubic metres We offer various types of extra equipment: * Hanger beams which allow transport of garments on hangers without further packing * Lashing bars...

78

Home Automation System; Automation i hemmet.  

E-Print Network [OSTI]

?? This project revolves around creating a home automation system prototype with the main focus being the ability to lock/unlock a door through the internet.… (more)

Ruwaida,, Bassam

2013-01-01T23:59:59.000Z

79

Automation of organic elemental analysis  

Science Journals Connector (OSTI)

Automation of organic elemental analysis ... Describes the development and design of an apparatus for automated organic elemental analysis. ...

Velmer B. Fish

1969-01-01T23:59:59.000Z

80

Insulation of Electrical Equipment  

Science Journals Connector (OSTI)

... A VACATION 'school' on the insulation of electrical equipment was held in the Electrical Engineering Department of the Imperial College of ... the universities. The purpose of the course was to consider the factors which are limiting insulation design in the main classes of electrical equipment, and the general principles which should ...

1952-12-13T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Commercial equipment cost database  

SciTech Connect (OSTI)

This report, prepared for DOE, Office of Codes and Standards, as part of the Commercial Equipment Standards Program at Pacific Northwest Laboratory, specifically addresses the equipment cost estimates used to evaluate the economic impacts of revised standards. A database including commercial equipment list prices and estimated contractor costs was developed, and through statistical modeling, estimated contractor costs are related to equipment parameters including performance. These models are then used to evaluate cost estimates developed by the ASHRAE 90.1 Standing Standards Project Committee, which is in the process of developing a revised ASHRAE 90.1 standard. The database will also be used to support further evaluation of the manufacturer and consumer impacts of standards. Cost estimates developed from the database will serve as inputs to economic modeling tools, which will be used to estimate these impacts. Preliminary results suggest that list pricing is a suitable measure from which to estimate contractor costs for commercial equipment. Models developed from these cost estimates accurately predict estimated costs. The models also confirm the expected relationships between equipment characteristics and cost. Cost models were developed for gas-fired and electric water heaters, gas-fired packaged boilers, and warm air furnaces for indoor installation. Because of industry concerns about the use of the data, information was not available for the other categories of EPAct-covered equipment. These concerns must be addressed to extend the analysis to all EPAct equipment categories.

Freeman, S.L.

1995-01-01T23:59:59.000Z

82

Experimental Equipment | Stanford Synchrotron Radiation Lightsource  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Equipment Equipment SSRL plans the distribution of its limited equipment on the basis of the information supplied on the Beam Time Request Form and the User Support Requirements Form. Please make sure to state all of your needs. Standard X-Ray Station Equipment Standard equipment to be found on an x-ray station includes: (1 ea.) Small and large ionization chambers (1) Exit slits (1) X-Y sample positioner (3) Keithly 427 current-to-voltage amplifier TEK 2215 60 MHZ 2 channel scope Voltage-to-frequency converter (3 channels) (1) Fluke high voltage power supply (1) Kinetic Systems hex scaler (1) Kinetic Systems up-down presettable counter (1) Ortec real-time clock (2) Joerger stepping motor controller DSP Micro VAX or Kinetic Systems G.I./CAMAC crate controller (1) Standard Engineering Corporation CAMAC power supply

83

Automation in biological crystallization  

Science Journals Connector (OSTI)

Automation is the response to overcoming the crystallization bottleneck in biological crystallography. This review provides a summary of the current methods and technologies applied in automated platforms for the setup of initial and follow-up crystallization experiments.

Shaw Stewart, P.

2014-05-28T23:59:59.000Z

84

Digital Control for Automation  

Science Journals Connector (OSTI)

GREATER YIELDS OF BETTER QUALITY PRODUCTS at reduced costs: That's one way to look at automations goal. And among instruments for automation are data reduction systems (others: continuous process analyzers, computer elements, and control mechanisms). ...

1956-04-02T23:59:59.000Z

85

AUTOMATION: Hints from OCAW  

Science Journals Connector (OSTI)

AUTOMATION: Hints from OCAW ... Labor and management need more, not less, collective bargaining in automated industries, he told a Houston, Tex., meeting of the Petro Group of the South Texas Section of the American Institute of Chemical Engineers. ...

1969-06-30T23:59:59.000Z

86

Definition: Automated Islanding And Reconnection | Open Energy Information  

Open Energy Info (EERE)

Islanding And Reconnection Islanding And Reconnection Jump to: navigation, search Dictionary.png Automated Islanding And Reconnection Automated Islanding and Reconnection Automated islanding and reconnection is achieved by automated separation and subsequent reconnection (autonomous synchronization) of an independently operated portion of the T&D system (i.e., microgrid) from the interconnected electric grid. A microgrid is an integrated energy system consisting of interconnected loads and distributed energy resources which, as an integrated system, can operate in parallel with the grid or as an island.[1] View on Wikipedia Wikipedia Definition Islanding refers to the condition in which a distributed (DG) generator continues to power a location even though electrical grid power

87

Theorie des langages Automates finis  

E-Print Network [OSTI]

Th´eorie des langages Automates finis Elise Bonzon http://web.mi.parisdescartes.fr/ bonzon/ elise.bonzon@parisdescartes.fr 1 / 51 Th´eorie des langages #12;Automates finis Automates finis Introduction Formalisation Repr´erations sur les automates Automates finis et langages 2 / 51 Th´eorie des langages #12;Automates finis

Bonzon, Elise

88

Multiplex automated genome engineering  

DOE Patents [OSTI]

The present invention relates to automated methods of introducing multiple nucleic acid sequences into one or more target cells.

Church, George M; Wang, Harris H; Isaacs, Farren J

2013-10-29T23:59:59.000Z

89

Congress Likes Automation  

Science Journals Connector (OSTI)

Congress Likes Automation ... Industry is generally aware of its responsibilities to worker replaced by automation, Congressional group concludes after broad study ... No NEW LEGISLATION or legislative changes are required to keep pace with the impact of automation on the national economy, concludes Rep. Wright Patman (D.-Tex.). ...

1955-11-07T23:59:59.000Z

90

Joint Genome Institute's Automation Approach and History  

E-Print Network [OSTI]

Joint Genome Institute’s Automation Approach and Historythroughput environment; – automation does not necessarilyissues “Islands of Automation” – modular instruments with

Roberts, Simon

2006-01-01T23:59:59.000Z

91

Strategy Guideline: HVAC Equipment Sizing  

SciTech Connect (OSTI)

The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

Burdick, A.

2012-02-01T23:59:59.000Z

92

Definition: Automated Capacitors | Open Energy Information  

Open Energy Info (EERE)

Capacitors Capacitors Jump to: navigation, search Dictionary.png Automated Capacitors Capacitors can increase the voltage on a distribution circuit by providing reactive power (often referred to as volt-amperes-reactive or VArs). Capacitor banks are switched in discrete steps, either manually, or in response to the voltage at the location where they are connected; typically, distribution capacitor banks are switched in a single step. If the voltage falls too far below the set point, the capacitor is switched in to raise the voltage. If the voltage rises too high above the set point, the capacitor is switched out to lower the voltage. Automated capacitors can be switched in coordination with other voltage control devices with signals from local sensors, distribution automation systems, or grid

93

Requirements Specification for and Evaluation of an Automated Substation Monitoring System  

E-Print Network [OSTI]

, without to much disruption in power supply to the users, Equipment Condition Monitoring (ECM) has to beRequirements Specification for and Evaluation of an Automated Substation Monitoring System Mladen for the Automated Analysis Substation System (AASS) implemented at Texas A&M University, aimed at monitoring

94

An Automation System for Optimizing a Supply Chain Network Design under the Influence of Demand Uncertainty  

E-Print Network [OSTI]

Automation . . . . . . . . . . . . . . . . . . . . . . iii 3Automation . . . . . . . . . . . . . . . . . . . . . . 5Dashboard/Cockpit Automation . . . . . . . . . . . . .

Polany, Rany

2012-01-01T23:59:59.000Z

95

Medical and Home automation Sensor Networks for Senior Citizens Telehomecare  

E-Print Network [OSTI]

Medical and Home automation Sensor Networks for Senior Citizens Telehomecare Shahram Nourizadeh1, 2 Healthcare, Smart Home, Distributed health record, Actimetry, Fuzzy logic, Home automation I. INTRODUCTION.Deroussent}@medetic.com Abstract- This paper presents a home Tele-healthcare system for the senior citizens. The system uses home

Paris-Sud XI, Université de

96

Equipment Insulation | Open Energy Information  

Open Energy Info (EERE)

List of Equipment Insulation Incentives Retrieved from "http:en.openei.orgwindex.php?titleEquipmentInsulation&oldid267163" Category: Articles with outstanding TODO tasks...

97

NSLS Electrical Equipment Inspection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electrical Equipment Inspection Information Electrical Equipment Inspection Information A note to vendors visiting NSLS A note to users visiting NSLS Proteus Electrical Conformity Remediation Currently Certified Electrical Equipment Inspectors: First Line Contacts Email Extension Poshka, Dennis poshka@bnl.gov 2825 Alternate Contacts Boerner Jr, Albert aboerner@bnl.gov 5990 Buda, Scott buda@bnl.gov 3914 Caruso, Michael caruso@bnl.gov 4100 Chmiel, Robert chmiel@bnl.gov 8141 Church, Randolph church@bnl.gov 2736 Clay, Barret clay@bnl.gov 7284 D'Alsace, Roy dalsace@bnl.gov 3973 Danneil, Christopher cdanneil@bnl.gov 8609 Davila, Peter davila@bnl.gov 7625 De Toll, Peter detoll@bnl.gov 4100 Durfee, Douglas ddurfee@bnl.gov 7625 Fulkerson, Michael fulkerso@bnl.gov 5194 Gallagher, John jgallagher@bnl.gov 5770 Harder, David dharder@bnl.gov 4978

98

Scientist Equipment and Outline  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Outline and Equipment Outline and Equipment LIGHT AND COLOR Grade levels: can be adapted for grades 2-8. Length of time: 30-45 minues. Room preference: Double classroom or all-purpose room. Equipment is located in the Lederman Science Center. Talk to Susan Dahl to borrow this set. Spectrum tube power supply, gas tubes and diffraction grating glasses Light box with red, green, and blue translucent film Power chord, extension chord Large set of lenses Small concave and convex lenses Magnetic optics kit, includes a small laser Slinky Flashlight Clear plastic tub, powdered milk Water Radiometer Electromagnetic energy spectrum poster Set of red, green and blue flood lights Where does light come from? Use a boy and a girl to make a human demonstration of molecules and atoms. Have students rub their hands together and notice friction equals heat.

99

Equipment Operational Requirements  

SciTech Connect (OSTI)

The Iraq Department of Border Enforcement is rich in personnel, but poor in equipment. An effective border control system must include detection, discrimination, decision, tracking and interdiction, capture, identification, and disposition. An equipment solution that addresses only a part of this will not succeed, likewise equipment by itself is not the answer without considering the personnel and how they would employ the equipment. The solution should take advantage of the existing in-place system and address all of the critical functions. The solutions are envisioned as being implemented in a phased manner, where Solution 1 is followed by Solution 2 and eventually by Solution 3. This allows adequate time for training and gaining operational experience for successively more complex equipment. Detailed descriptions of the components follow the solution descriptions. Solution 1 - This solution is based on changes to CONOPs, and does not have a technology component. It consists of observers at the forts and annexes, forward patrols along the swamp edge, in depth patrols approximately 10 kilometers inland from the swamp, and checkpoints on major roads. Solution 2 - This solution adds a ground sensor array to the Solution 1 system. Solution 3 - This solution is based around installing a radar/video camera system on each fort. It employs the CONOPS from Solution 1, but uses minimal ground sensors deployed only in areas with poor radar/video camera coverage (such as canals and streams shielded by vegetation), or by roads covered by radar but outside the range of the radar associated cameras. This document provides broad operational requirements for major equipment components along with sufficient operational details to allow the technical community to identify potential hardware candidates. Continuing analysis will develop quantities required and more detailed tactics, techniques, and procedures.

Greenwalt, B; Henderer, B; Hibbard, W; Mercer, M

2009-06-11T23:59:59.000Z

100

CIMplementation™: Evaluating Manufacturing Automation  

E-Print Network [OSTI]

in the manufacturing organization if CIMplementation~* is to succeed. 1.0 INTRODUCTION There is much discussion today about Com puter Integrated Manufacturing (CIM). Automation tools like Computer Aided Design (CAD) systems, robots, automated material handling...~ Pressing the frontier of technology in one's own manufactur ing facility will not be without its pitfalls. Second, while automation engineers may be able to piece together the technological pieces of a CIM system, they cannot and do not evaluate...

Krakauer, J.

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

IPv6 Home Automation.  

E-Print Network [OSTI]

?? Home automation is the systematic controlling and monitoring of everyday home devices such as lighting, heating, window blinds and appliances (both white goods and… (more)

Hådén, Thor

2009-01-01T23:59:59.000Z

102

Vehicle highway automation.  

E-Print Network [OSTI]

??Vehicle Highway Automation has been studied for several years but a practical system has not been possible because of technology limitations. New advances in sensing… (more)

Challa, Dinesh Kumar

2009-01-01T23:59:59.000Z

103

Emergency Facilities and Equipment  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This volume clarifies requirements of DOE O 151.1 to ensure that emergency facilities and equipment are considered as part of emergency management program and that activities conducted at these emergency facilities are fully integrated. Canceled by DOE G 151.1-4.

1997-08-21T23:59:59.000Z

104

Equipment for ?-Radiography  

Science Journals Connector (OSTI)

... felt for a well-designed protective carrier and exposure unit for use with radium or radon. The announcement that Johnson Matthey and Co., Ltd., are manufacturing protective equipment ... will assist the industrial radiologist to take advantage of the improved supplies of radium and radon which are now available (Nature, June 4, 1949, p. 867). ...

1949-09-10T23:59:59.000Z

105

Laboratory automation-A case history  

Science Journals Connector (OSTI)

Laboratory automation-A case history ... This article describes an automated Raman spectrometer. ...

Bernard J. Bulkin; Edward H. Cole; Arthur Noguerola

1974-01-01T23:59:59.000Z

106

Automated Demand Response and Commissioning  

E-Print Network [OSTI]

Fully-Automated Demand Response Test in Large Facilities14in DR systems. Demand Response using HVAC in Commercialof Fully Automated Demand Response in Large Facilities”

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Bourassa, Norman

2005-01-01T23:59:59.000Z

107

Autonomic Product Development Process Automation.  

E-Print Network [OSTI]

??Market globalization and mass customization requirements are forcing companies towards automation of their product development processes. Many task-specific software solutions provide localized automation. Coordinating these… (more)

Daley, John E.

2007-01-01T23:59:59.000Z

108

E-Print Network 3.0 - automated fault extraction Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

with extracted... automation, fault diagnosis, asset management, as well as power system modeling and simulation. 12;... 1 F Voltage Sag Data Utilization for Distribution Fault...

109

Design, Simulation, and Analysis of Substation Automation Networks  

E-Print Network [OSTI]

on the Substation Automation Systems (SAS). Substations are nodes in the smart grid infrastructure that help the in transportation of power by connecting the transmission and distribution lines. The SAS applications are con figured to operate with minimal human...

Kembanur Natarajan, Elangovan

2012-07-16T23:59:59.000Z

110

Human-automation collaborative RRT for UAV mission path planning  

E-Print Network [OSTI]

Future envisioned Unmanned Aerial Vehicle (UAV) missions will be carried out in dynamic and complex environments. Human-automation collaboration will be required in order to distribute the increased mission workload that ...

Caves, Américo De Jesús (Caves Corral)

2010-01-01T23:59:59.000Z

111

Automation Creates New Managers  

Science Journals Connector (OSTI)

AUTOMATION will bring about new and broader patterns in the use of labor and creation of a large group of managers of a new type, says E. W. Engstrom, senior executive vice president of the Radio Corporation of America. With automation, there will no ...

1955-12-12T23:59:59.000Z

112

field_equipment.indd  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

EQUIPMENT INVENTORY EQUIPMENT INVENTORY Trucks * Five vac/pressure trucks, 60-90 bbl, up to 5 bpm at 5,000 lb. * Water/fi re truck, 110 bbl * Two dump trucks: 5-yard and 12-yard * Belly dump trailer * Chemical injection truck, 20 bbl capacity * Three crane trucks: 6,000 lb., 8,000 lb., and 30 ton * Klaeger swab truck * Rig-up truck with 21-foot poles, 30,000-lb. capacity * Winch truck, 40,000-lb. capacity * Two bucket trucks: 25-foot and 28-foot reach * Two welding trucks with Miller Trailblazer welder * Two Ditch Witches: 8" x 7' and 6" x 3" * International PayStar 5000 transport truck * Western Star transport truck Backhoes & Loaders * John Deere 410G backhoe * Cat 420 backhoe * Case 20W loader with 2-yard bucket * Bobcat skid loader with bucket, forks, post hole digger, and trencher attachments

113

Distribution:  

Office of Legacy Management (LM)

JAN26 19% JAN26 19% Distribution: OR00 Attn: h.H.M.Roth DFMusser ITMM MMMann INS JCRyan FIw(2) Hsixele SRGustavson, Document rocm Formal file i+a@mmm bav@ ~@esiaw*cp Suppl. file 'Br & Div rf's s/health (lic.only) UNITED STATES ATOMIC ENERGY COMMISSION SPECIAL NUCLEAB MATERIAL LICENSE pursuant to the Atomic Energy Act of 1954 and Title 10, Code of Federal Regulations, Chapter 1, P&t 70, "Special Nuclear Material Reg)llatiqm," a license is hereby issued a$hortztng the licensee to rekeive and possess the special nuclear material designated below; to use such special nuclear mat&ial for the purpose(s) and at the place(s) designated below; and to transfer such material to per&s authorized to receive it in accordance with the regula,tions in said Part.

114

Equipment Certification | Open Energy Information  

Open Energy Info (EERE)

Equipment Certification Equipment Certification Jump to: navigation, search Policies requiring renewable energy equipment to meet certain standards serve to protect consumers from buying inferior equipment. These requirements not only benefit consumers; they also protect the renewable energy industry by making it more difficult for substandard systems to reach the market. [1] Equipment Certification Incentives CSV (rows 1 - 19) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Canada Oil and Gas Operations Act (Canada) Environmental Regulations Equipment Certification Fees Generating Facility Rate-Making Generation Disclosure Industry Recruitment/Support Safety and Operational Guidelines Siting and Permitting Canada Commercial Construction Developer

115

Cognitive Engineering Automation and Human  

E-Print Network [OSTI]

· Home automation · Robotics · Unmanned vehicles (UAVs and UGVs) · Drug design/Molecular geneticsCognitive Engineering PSYC 530 Automation and Human Performance Raja Parasuraman #12;Overview Automation-Related Accidents Levels and Stages of Automation Information Acquisition and Analysis Decision

Parasuraman, Raja

116

Automation of Feynman Diagram Evaluation  

E-Print Network [OSTI]

A C-program DIANA (DIagram ANAlyser) for the automation of Feynman diagram evaluations is presented.

M. Tentyukov; J. Fleischer

1998-02-04T23:59:59.000Z

117

Role of Standard Demand Response Signals for Advanced Automated Aggregation  

SciTech Connect (OSTI)

Emerging standards such as OpenADR enable Demand Response (DR) Resources to interact directly with Utilities and Independent System Operators to allow their facility automation equipment to respond to a variety of DR signals ranging from day ahead to real time ancillary services. In addition, there are Aggregators in today’s markets who are capable of bringing together collections of aggregated DR assets and selling them to the grid as a single resource. However, in most cases these aggregated resources are not automated and when they are, they typically use proprietary technologies. There is a need for a framework for dealing with aggregated resources that supports the following requirements: • Allows demand-side resources to participate in multiple DR markets ranging from wholesale ancillary services to retail tariffs without being completely committed to a single entity like an Aggregator; • Allow aggregated groups of demand-side resources to be formed in an ad hoc fashion to address specific grid-side issues and support the optimization of the collective response of an aggregated group along a number of different dimensions. This is important in order to taylor the aggregated performance envelope to the needs to of the grid; • Allow aggregated groups to be formed in a hierarchical fashion so that each group can participate in variety of markets from wholesale ancillary services to distribution level retail tariffs. This paper explores the issues of aggregated groups of DR resources as described above especially within the context of emerging smart grid standards and the role they will play in both the management and interaction of various grid-side entities with those resources.

Lawrence Berkeley National Laboratory; Kiliccote, Sila

2011-11-18T23:59:59.000Z

118

Early Equipment Management  

E-Print Network [OSTI]

starting with the ones that could cause the most human harm. This is also an excellent time to discuss all the lockout/tagout points on the machine, determine how much safety training is necessary and if there are enough warning stickers. The idea... needed. One-point lessons should be completed on all inspection, lubrication, and lockout/tagout points. Equipment labels should be created at this time including lockout/tagout and predetermined set-points. The key to a successful EEM program...

Schlie, Michelle

2007-05-18T23:59:59.000Z

119

China production equipment sourcing strategy  

E-Print Network [OSTI]

This thesis recommends a China business and equipment strategy for the Controls Conveyor Robotics Welding (CCRW) group at General Motors. The current strategy is to use globally common equipment through predetermined global ...

Chouinard, Natalie, 1979-

2009-01-01T23:59:59.000Z

120

IAEA safeguards equipment  

Science Journals Connector (OSTI)

The International Atomic Energy Agency (IAEA) operates a large diversity of equipment to verify nuclear materials, contributing to the confirmation of the states' compliance with their respective nonproliferation obligations. The variety of physical and chemical properties of nuclear materials, as well as their storage environment, requires an arsenal of instruments. Additionally, the IAEA applies various containment and surveillance measures to maintain the continuity of knowledge on nuclear materials. The IAEA need ongoing equipment development to provide its inspectorate with the state-of-the-art tools for performing various safeguards activities. These activities include the measurement of declared nuclear material inventories and flows, the application of enhanced containment and surveillance measures and the search for the indicators of undeclared nuclear material and clandestine nuclear activities. The IAEA is facing increasing demands to perform remote verification of nuclear material flows utilising unattended monitoring systems. Additional analytical capabilities and effective non-destructive assay methods will be indispensable in the future for reinforcing the IAEA's ability to detect undeclared nuclear materials and activities.

M. Zendel

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Shielded cells transfer automation  

SciTech Connect (OSTI)

Nuclear waste from shielded cells is removed, packaged, and transferred manually in many nuclear facilities. Radiation exposure is absorbed by operators during these operations and limited only through procedural controls. Technological advances in automation using robotics have allowed a production waste removal operation to be automated to reduce radiation exposure. The robotic system bags waste containers out of glove box and transfers them to a shielded container. Operators control the system outside the system work area via television cameras. 9 figures.

Fisher, J J

1984-01-01T23:59:59.000Z

122

Automated Lattice Perturbation Theory  

SciTech Connect (OSTI)

I review recent developments in automated lattice perturbation theory. Starting with an overview of lattice perturbation theory, I focus on the three automation packages currently "on the market": HiPPy/HPsrc, Pastor and PhySyCAl. I highlight some recent applications of these methods, particularly in B physics. In the final section I briefly discuss the related, but distinct, approach of numerical stochastic perturbation theory.

Monahan, Christopher

2014-11-01T23:59:59.000Z

123

Home Network Technologies and Automating Demand Response  

E-Print Network [OSTI]

potential role of home automation networks in implementinghow existing and future home automation systems may providehome networks" and "home automation" are frequently used

McParland, Charles

2010-01-01T23:59:59.000Z

124

Development of Building Automation and Control Systems  

E-Print Network [OSTI]

A design flow for building automation and control systems,’’Development of Building Automation and Control Systems Yangdesign of the build- ing automation system (including the

Yang, Yang; Zhu, Qi; Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

125

Automated Demand Response Opportunities in Wastewater Treatment Facilities  

SciTech Connect (OSTI)

Wastewater treatment is an energy intensive process which, together with water treatment, comprises about three percent of U.S. annual energy use. Yet, since wastewater treatment facilities are often peripheral to major electricity-using industries, they are frequently an overlooked area for automated demand response opportunities. Demand response is a set of actions taken to reduce electric loads when contingencies, such as emergencies or congestion, occur that threaten supply-demand balance, and/or market conditions occur that raise electric supply costs. Demand response programs are designed to improve the reliability of the electric grid and to lower the use of electricity during peak times to reduce the total system costs. Open automated demand response is a set of continuous, open communication signals and systems provided over the Internet to allow facilities to automate their demand response activities without the need for manual actions. Automated demand response strategies can be implemented as an enhanced use of upgraded equipment and facility control strategies installed as energy efficiency measures. Conversely, installation of controls to support automated demand response may result in improved energy efficiency through real-time access to operational data. This paper argues that the implementation of energy efficiency opportunities in wastewater treatment facilities creates a base for achieving successful demand reductions. This paper characterizes energy use and the state of demand response readiness in wastewater treatment facilities and outlines automated demand response opportunities.

Thompson, Lisa; Song, Katherine; Lekov, Alex; McKane, Aimee

2008-11-19T23:59:59.000Z

126

Measured Peak Equipment Loads in Laboratories  

E-Print Network [OSTI]

of measured equipment load data for laboratories, designersmeasured peak equipment load data from 39 laboratory spacesmeasured equipment load data from various laboratory spaces

Mathew, Paul A.

2008-01-01T23:59:59.000Z

127

Electrical Equipment Inventory and Inspection Information  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Electrical Equipment Inventory and Inspection Information APS Non-NRTL Electrical Equipment Inventory Spreadsheet ANL Recognized Reputable Electrical Equipment Manufacturer List as...

128

Automated Fault Location In Smart Distribution Systems  

E-Print Network [OSTI]

measured at the power substation during a single phase to ground fault clearance [17] .............................................. 111 Figure 26 Analyzed signal using wavelet transform from phase B current during a fault [17..., but are not limited to, substation and feeder relay, intelligent controllers for capacitor bank switches or reclosers, Automatic Meter Reading (AMR) systems installed at the customer sites, power quality meters installed at strategic locations in the system, low...

Lotfifard, Saeed

2012-10-19T23:59:59.000Z

129

About Genco Energy Services Genco Energy Services has been servicing the rental equipment needs  

E-Print Network [OSTI]

and insurance costs; increased employee safety and productivity Industry Focus Rental equipment for oil and gas and natural gas production. Approximately 150 employees service hundreds of jobs at any given time by moving in more errors and lost productivity. The company needed to automate its asset management processes

Fisher, Kathleen

130

Honeywell Demonstrates Automated Demand Response Benefits for...  

Broader source: Energy.gov (indexed) [DOE]

Honeywell Demonstrates Automated Demand Response Benefits for Utility, Commercial, and Industrial Customers Honeywell Demonstrates Automated Demand Response Benefits for Utility,...

131

AUTOMATED CRITICAL PEAK PRICING FIELD TESTS  

E-Print Network [OSTI]

AUTOMATED CRITICAL PEAK PRICING FIELD TESTS: 2006 PROGRAM DESCRIPTION AND RESULTS APPENDICES.................................................................................... 5 B.2. DR Automation Server User Guide

132

Development of Building Automation and Control Systems  

E-Print Network [OSTI]

Johnson Controls, 70 in Automated Logic EIKON language, 42systems developed by Automated Logic. Similarly as shown in

Yang, Yang; Zhu, Qi; Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

133

Definition: Automated Voltage Regulators | Open Energy Information  

Open Energy Info (EERE)

Regulators Regulators Jump to: navigation, search Dictionary.png Automated Voltage Regulators Voltage regulators are transformers that can increase or decrease the voltage on a distribution circuit to help keep the voltage within a pre-determined band. Unlike capacitor banks, voltage regulators cannot adjust power factor. These devices typically monitor the voltage at the location where they are connected, and compare it to a programmed set point. If the voltage deviates too far from the set point, the voltage regulator can increase or decrease its output voltage by moving the tap on the secondary side up or down. An automated voltage regulator can operate with remote control signals, or in concert with other area voltage control devices, to help regulate distribution voltage in a coordinated fashion.

134

HIGHLY AUTOMATED MACROMOLECULAR  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AUTOMATED MACROMOLECULAR AUTOMATED MACROMOLECULAR CRYSTALLOGRAPHY BEAMLINE (AMX) Group Leader: Dieter Schneider Proposal Team: M. Allaire 1 , L. Berman 1 , M. Chance 2 , W. Hendrickson 3 , A. Héroux 1 , J. Jakoncic 1 , A. Orville 1 , H. Robinson 1 , D. Schneider 1 , W. Shi 2 , A. Soares 1 , V. Stojanoff 1 , R. Sweet 1 1 Brookhaven National Laboratory, 2 Case Western Reserve University, 3 Columbia University MISSION APPLICATIONS AND CAPABILITIES ADDITIONAL INFORMATION * AMX at NSLS-II will provide structural biologists with ready access to an advanced macromolecular crystallography (MX) beamline for the elucidation of structure and function of macromolecular complexes. * Its high flux, tunable energy, and natively small focal spot will make it a crystallographer's preferred beamline. * Its high degree of automation will provide a high throughput

135

Automation Status | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Automation Status Automation Status Presented at the NREL Hydrogen and Fuel Cell Manufacturing R&D Workshop in Washington, DC, August 11-12, 2011. mfg2011plenarysperrick.pdf More...

136

Automation on the laboratory bench  

Science Journals Connector (OSTI)

Automation on the laboratory bench ... In designing an automation kit the authors attempted to give chemistry a system which is versatile and easy to apply in taking over the boring and difficult task of controlling parameters manually. ...

M. Legrand; A. Foucard

1978-01-01T23:59:59.000Z

137

Information technology equipment cooling system  

SciTech Connect (OSTI)

According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

Schultz, Mark D.

2014-06-10T23:59:59.000Z

138

INL '@work' heavy equipment mechanic  

ScienceCinema (OSTI)

INL's Cad Christensen is a heavy equipment mechanic. For more information about INL careers, visit http://www.facebook.com/idahonationallaboratory.

Christensen, Cad

2013-05-28T23:59:59.000Z

139

Commercial Kitchen & Food Service Equipment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Commercial Commercial Industrial Lighting Energy Smart Grocer Program HVAC Program Shell Measures Commercial Kitchen & Food Service Equipment Plug Load New...

140

Commercial Cooking Equipment | Open Energy Information  

Open Energy Info (EERE)

Cooking Equipment Incentives Retrieved from "http:en.openei.orgwindex.php?titleCommercialCookingEquipment&oldid38063...

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Food Service Equipment | Open Energy Information  

Open Energy Info (EERE)

Service Equipment Incentives Retrieved from "http:en.openei.orgwindex.php?titleFoodServiceEquipment&oldid380620...

142

Automation: Congress' Next Probe  

Science Journals Connector (OSTI)

THE stage is being set for a Congressional investigation of the trend toward automation in industry. From all indications, this could become one of the hottest subjects in labor-management relations during the coming year.Formal hearings have been ...

1955-08-29T23:59:59.000Z

143

Automation of Capacity Bidding with an Aggregator Using Open Automated Demand Response  

E-Print Network [OSTI]

Protocol for Building Automation and Control  Networks.  Protocol for Building Automation and Control  Networks, Demand Response Automation Server  Demand Response Research 

Kiliccote, Sila

2011-01-01T23:59:59.000Z

144

Automation Trend Continues  

Science Journals Connector (OSTI)

IT is difficult to discern any brand new trends in chemical process equipment this year which were not evident a year ago. However, at National Chemical Exposition, David E. Pierce, Diamond Alkali Corp., in his Industrial and Engineering Chemistry Lecture,...

1954-11-01T23:59:59.000Z

145

Automated Proactive Techniques for Commissioning Air-Handling Units  

SciTech Connect (OSTI)

Many buildings today use sophisticated building automation systems (BASs) to manage a wide and varied range of building systems. Although the capabilities of the BASs seem to have increased over time, many buildings still are not properly commissioned, operated or maintained. Lack of or improper commissioning, the inability of the building operators to grasp the complex controls, and lack of proper maintenance leads to inefficient operations and reduced lifetimes of the equipment. If regularly scheduled manual maintenance or re-commissioning practices are adopted, they can be expensive and time consuming. Automated proactive commissioning and diagnostic technologies address two of the main barriers to commissioning: cost and schedules. Automated proactive continuous commissioning tools can reduce both the cost and time associated with commissioning, as well as enhance the persistence of commissioning fixes. In the long run, automation even offers the potential for automatically correcting problems by reconfiguring controls or changing control algorithms dynamically. This paper will discuss procedures and processes that can be used to automate and continuously commission the economizer operation and outdoor-air ventilation systems of an air-handling unit.

Katipamula, Srinivas (BATTELLE (PACIFIC NW LAB)); Brambley, Michael R. (BATTELLE (PACIFIC NW LAB)); Luskay, Larry (Portland Energy Conservation, Inc.)

2003-08-30T23:59:59.000Z

146

Definition: Automated Feeder And Line Switching | Open Energy Information  

Open Energy Info (EERE)

Definition Definition Edit with form History Facebook icon Twitter icon » Definition: Automated Feeder And Line Switching Jump to: navigation, search Dictionary.png Automated Feeder And Line Switching Automated feeder and line switching is realized through automatic isolation and reconfiguration of faulted segments of distribution feeders or transmission lines via sensors, controls, switches, and communications systems. These devices can operate autonomously in response to local events or in response to signals from a central control system.[1] Related Terms transmission lines, transmission line References ↑ SmartGrid.gov 'Description of Functions' An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Automated_Feeder_And_Line_Switching&oldid=480562"

147

TRANSPORT AND EMPLACEMENT EQUIPMENT DESCRIPTIONS  

SciTech Connect (OSTI)

The objective and the scope of this document are to list and briefly describe the major mobile equipment necessary for waste package (WP) Transport and Emplacement in the proposed subsurface nuclear waste repository at Yucca Mountain. Primary performance characteristics and some specialized design features of the equipment are explained and summarized in the individual subsections of this document. The Transport and Emplacement equipment described in this document consists of the following: (1) WP Transporter; (2) Reusable Rail Car; (3) Emplacement Gantry; (4) Gantry Carrier; and (5) Transport Locomotive.

NA

1997-09-29T23:59:59.000Z

148

Nanjing Sunec Wind Generator Equipment Factory | Open Energy Information  

Open Energy Info (EERE)

Sunec Wind Generator Equipment Factory Sunec Wind Generator Equipment Factory Jump to: navigation, search Name Nanjing Sunec Wind Generator Equipment Factory Place Nanjing, Jiangsu Province, China Zip 211100 Sector Wind energy Product A Chinese manufacturer for power supply, grid automation equipment and small-to-medium wind turbines, as well as a wind project developer. Coordinates 32.0485°, 118.778969° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":32.0485,"lon":118.778969,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

149

Automated gas chromatography  

DOE Patents [OSTI]

An apparatus and process for the continuous, near real-time monitoring of low-level concentrations of organic compounds in a liquid, and, more particularly, a water stream. A small liquid volume of flow from a liquid process stream containing organic compounds is diverted by an automated process to a heated vaporization capillary where the liquid volume is vaporized to a gas that flows to an automated gas chromatograph separation column to chromatographically separate the organic compounds. Organic compounds are detected and the information transmitted to a control system for use in process control. Concentrations of organic compounds less than one part per million are detected in less than one minute. 7 figs.

Mowry, C.D.; Blair, D.S.; Rodacy, P.J.; Reber, S.D.

1999-07-13T23:59:59.000Z

150

Laboratory Equipment Donation Program - Guidelines  

Office of Scientific and Technical Information (OSTI)

The United States Department of Energy, in accordance with its The United States Department of Energy, in accordance with its responsibility to encourage research and development in the energy area, awards grants of used energy-related laboratory equipment. Universities, colleges and other non-profit educational institutions of higher learning in the United States are eligible to apply for equipment to use in energy-oriented educational programs in the life, physical, and environmental sciences, and in engineering. The equipment listed in this database is available for grant; however, specific items may be recalled for DOE use and become unavailable through the program. Frequently Asked Questions Who is eligible to apply for equipment? Any non-profit, educational institution of higher learning, such as a middle school, high school, university, college, junior college, technical

151

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Single Package Vertical Air Conditioners and Heat Pumps Single Package Vertical Air Conditioners and Heat Pumps Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's energy conservation standards for single package vertical air conditioners and heat pumps as a separate equipment class since 2008. Before 2010, this equipment was regulated under the broader scope of commercial air conditioning and heating equipment. Single package vertical air conditioners and heat pumps are commercial air conditioning and heating equipment with its main components arranged in a vertical fashion. They are mainly used in modular classrooms, modular office buildings, telecom shelters, and hotels, and are typically installed on the outside of an exterior wall or in a closet against an exterior wall but inside the building.

152

LANSCE | Lujan Center | Ancillary Equipment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ancillary Equipment Ancillary Equipment For general questions, please contact the Lujan Center Sample Environments responsible: Victor Fanelli | vfanelli@lanl.gov | 505.667.8755 Sample and Equipment Shipping Instructions For questions regarding shipping procedures, contact Lujan Center Experiment Coordinator: Leilani Conradson | leilani@lanl.gov | 505.665.9505 Low Temperature Equipment Specifications Flight Path/Instrument Compatibility Responsible Displex closed-cycle refrigerators Tmin= 4 K to 12 K Tmax= 300 K to 340 K 11 - Asterix 04 - HIPPO 03 - HIPD 10 - LQD 02 - SMARTS Victor Fanelli vfanelli@lanl.gov Or particular instrument scientist Top loading closed-cycle refrigerator T = 10 K to 500 K option of in situ gas adsorption cell 07 - FDS Luke Daemon lld@lanl.gov Monika Hartl hartl@lanl.gov

153

Equipment Inventory | Sample Preparation Laboratories  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Resources Title Equipment Type Facility Laboratory Building Room Accumet Basic AB15 pH meter pH Meter SSRL BioChemMat Prep Lab 2 131 209 Agate Mortar & Pestle Sets Agilent 8453...

154

Earth-Fault Relay Equipment  

Science Journals Connector (OSTI)

... proving the reliability of the equipment. By Observing the operation of the relays at each substation with faults at selected points, the complete scheme can be put into operation with ...

1944-04-15T23:59:59.000Z

155

Bulk Hauling Equipment for CHG  

Broader source: Energy.gov (indexed) [DOE]

load of CHG Semitrailer Mass Trailer or ModuleChassis Module Mass Hydrogen Gas Mass CAPITAL EXPENDITURE FOR BULK HAULING EQUIPMENT For large consumption, total CapEx for...

156

Certified APS Electrical Equipment Inspectors  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

APS Designated Electrical Equipment Inspectors : Division Phone Page e-mail Jonathan Baldwin XSD 2-6977 4-6977 jbaldwin@aps.anl.gov Adam Brill ASD 2-9968 4-4559 abrill@aps.anl.gov...

157

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Direct Heating Equipment and Pool Heaters Active Mode Test Procedures Direct Heating Equipment and Pool Heaters Active Mode Test Procedures Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is proposing to amend the active mode test procedures for direct heating equipment and pool heaters. This rulemaking is mandated by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a notice of proposed rulemaking regarding active mode test procedures for direct heating equipment and pool heaters. 78 FR 63410 (October 24, 2013). The comment deadline is January 7, 2014. Public Meeting Information

158

Automated Job Hazards Analysis  

Broader source: Energy.gov [DOE]

AJHA Program - The Automated Job Hazard Analysis (AJHA) computer program is part of an enhanced work planning process employed at the Department of Energy's Hanford worksite. The AJHA system is routinely used to performed evaluations for medium and high risk work, and in the development of corrective maintenance work packages at the site. The tool is designed to ensure that workers are fully involved in identifying the hazards, requirements, and controls associated with tasks.

159

TJ Automation | Open Energy Information  

Open Energy Info (EERE)

TJ Automation TJ Automation Jump to: navigation, search Name TJ Automation Facility TJ Automation Sector Wind energy Facility Type Small Scale Wind Facility Status In Service Owner TJ Automation Energy Purchaser TJ Automation Location Archbold OH Coordinates 41.45823855°, -84.30666804° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.45823855,"lon":-84.30666804,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

160

Report blasts Patent Office automation  

Science Journals Connector (OSTI)

Report blasts Patent Office automation ... The Department of Commerce is moving quickly to implement a report highly critical of the Patent & Trademark Office's efforts to fully automate its patent search and retrieval operations. ... An Industry Review Panel found that the current automated patent system is over-designed and as a result needs a redundant communications network and redundant storage of all patent images at high resolution. ...

JANICE LONG

1988-05-30T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Honeywell Modular Automation System Acceptance Test Procedure  

SciTech Connect (OSTI)

The purpose of this Acceptance Test Procedure (ATP) is to verify the operability of the three new furnaces as controlled by the new Honeywell Modular Automation System (MAS). The Honeywell MAS is being installed in PFP to control the three thermal stabilization furnaces in glovebox HA-211. The ATP provides instructions for testing the configuration of the Honeywell MAS at the Plutonium Finishing Plant(PFP). The test will be a field test of the analog inputs, analog outputs, and software interlocks. The interlock test will check the digital input and outputs. Field equipment will not be connected forth is test. Simulated signals will be used to test thermocouple, limit switch, and vacuum pump inputs to the PLUMAS.

STUBBS, A.M.

1999-09-21T23:59:59.000Z

162

Manz Automation AG | Open Energy Information  

Open Energy Info (EERE)

AG AG Jump to: navigation, search Name Manz Automation AG Place Reutlingen, Baden-Württemberg, Germany Zip D-72768 Sector Solar Product German manufacturer of solar and LCD capital equipment. Coordinates 48.49159°, 9.21487° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":48.49159,"lon":9.21487,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

163

Virtual Machine in Automation Projects.  

E-Print Network [OSTI]

?? Virtual machine, as an engineering tool, has recently been introduced into automation projects in Tetra Pak Processing System AB. The goal of this paper… (more)

Xing, Xiaoyuan

2010-01-01T23:59:59.000Z

164

Permit for Charging Equipment Installation: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Compliance with the following permit will allow the installation and operation of electric vehicle charging equipment at a Compliance with the following permit will allow the installation and operation of electric vehicle charging equipment at a residence in the City, State jurisdiction. This permit addresses one of the following situations: Only an additional branch circuit would be added at the residence A hard-wired charging station would be installed at the residence. The attached requirements for wiring the charging station are taken directly out of the 2011 edition of the National Electrical Code (NEC) NFPA 70, Article 625 Electric Vehicle Charging System. This article does not provide all of the information necessary for the installation of electric vehicle charging equipment. Please refer to the current edition of the electrical code adopted by the local jurisdiction for additional installation requirements. Reference to the 2011 NEC may be

165

AUTOMATED ~.JELDING -RESEARCH NEEDS T. H. Eagar  

E-Print Network [OSTI]

) ) ..... . '. AUTOMATED ~.JELDING - RESEARCH NEEDS T. H. Eagar Department of Naterials Science and Engineering Nassachusetts Institute of Technology Cambridge, Hassachusetts 02139 Increased use of automated is necessary in order to develop reliable automated welding techniques. #12;Introduction During the past decade

Eagar, Thomas W.

166

Automation improves personal effectiveness while reducing drudgery  

Science Journals Connector (OSTI)

Automation improves personal effectiveness while reducing drudgery ... "The term automation ," says one Department of Labor official with undisguised feeling, "is a hopeless semantic jungle." ... One industry man defines automation very loosely as any way of doing things better with machines. ...

1966-03-14T23:59:59.000Z

167

Materials Selection Considerations for Thermal Process Equipment...  

Broader source: Energy.gov (indexed) [DOE]

Materials Selection Considerations for Thermal Process Equipment: A BestPractices Process Heating Technical Brief Materials Selection Considerations for Thermal Process Equipment:...

168

CRAD, Nuclear Facility Construction - Mechanical Equipment -...  

Office of Environmental Management (EM)

Nuclear Facility Construction - Mechanical Equipment - June 26, 2012 CRAD, Nuclear Facility Construction - Mechanical Equipment - June 26, 2012 June 26, 2012 Nuclear Facility...

169

Request an Inspection of User Electrical Equipment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Request for an Electrical Equipment Inspection All APS User electronic and electrical equipment must be inspected before use in an experiment. Please ask your beamline to make...

170

Summary of Construction Equipment Tests and Activities  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Equipment Tests A series of tests were conducted by the APS Construction Vibration Measurement Task Force using various pieces of construction equipment at the APCF...

171

Best Management Practice #11: Commercial Kitchen Equipment  

Broader source: Energy.gov [DOE]

Commercial kitchen equipment represents a large set of water users in the non-residential sector. Water efficiency for commercial kitchen equipment is especially important because high volume...

172

Northwest Open Automated Demand Response Technology Demonstration Project  

E-Print Network [OSTI]

Facility Technician) Automated Logic Corporation: Ivanembedded in the Target’s Automated Logic Corporation (ALC)

Kiliccote, Sila

2010-01-01T23:59:59.000Z

173

Automated fiber pigtailing machine  

DOE Patents [OSTI]

The Automated Fiber Pigtailing Machine (AFPM) aligns and attaches optical fibers to optoelectronic (OE) devices such as laser diodes, photodiodes, and waveguide devices without operator intervention. The so-called pigtailing process is completed with sub-micron accuracies in less than 3 minutes. The AFPM operates unattended for one hour, is modular in design and is compatible with a mass production manufacturing environment. This machine can be used to build components which are used in military aircraft navigation systems, computer systems, communications systems and in the construction of diagnostics and experimental systems. 26 figs.

Strand, O.T.; Lowry, M.E.

1999-01-05T23:59:59.000Z

174

Chapter 11 - Industrial Automation  

Science Journals Connector (OSTI)

The industrial systems of the future are complex systems composed of vast numbers of devices interacting with each other and with enterprise systems. Modern technologies such as web services, service-oriented architectures (SOAs), the cloud, etc. make it possible for sophisticated infrastructures to emerge in future factories. We take a closer look at key visionary aspects that are expected to be introduced in the industrial automation domain in the years to come, and the pivotal role of M2M and IoT. Additionally, we investigate the impact on the collaboration of machines among themselves and with enterprise systems and their services.

Jan Höller; Vlasios Tsiatsis; Catherine Mulligan; Stamatis Karnouskos; Stefan Avesand; David Boyle

2014-01-01T23:59:59.000Z

175

Automating dipole subtraction  

E-Print Network [OSTI]

We report on automating the Catani-Seymour dipole subtraction which is a general procedure to treat infrared divergences in real emission processes at next-to-leading order in QCD. The automatization rests on three essential steps: the creation of the dipole terms, the calculation of the color linked squared Born matrix elements, and the evaluation of different helicity amplitudes. The routines have been tested for a number of complex processes, such as the real emission process gg --> t anti-t ggg.

K. Hasegawa; S. Moch; P. Uwer

2008-07-23T23:59:59.000Z

176

PNNL: EDO - Facilities & Equipment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Facilities & Equipment Facilities & Equipment Facilities Equipment Decades of government investment on and around the Pacific Northwest National Laboratory campus has made PNNL a business-friendly resource for conducting a wide range of research. As a mission-focused organization, we are dedicated to teaming with government agencies, industry and academia to address what we believe are among the nation's most pressing needs in the areas of energy, environment, national security, and fundamental science. But behind these important missions is a wealth of supporting capabilities including incubator space, research laboratories, and user facilities that may be just what your business needs. We invite you to learn more about how we can work with businesses as well as what research laboratories and user facilities are available.

177

Installation and Commissioning Automated Demand Response Systems  

E-Print Network [OSTI]

their partnership in demand response automation research andand Techniques for Demand Response. LBNL Report 59975. Mayof Fully Automated Demand Response in Large Facilities.

Kiliccote, Sila; Global Energy Partners; Pacific Gas and Electric Company

2008-01-01T23:59:59.000Z

178

Home Network Technologies and Automating Demand Response  

E-Print Network [OSTI]

and Automating Demand Response Charles McParland, Lawrenceand Automating Demand Response Charles McParland, LBNLCommercial and Residential Demand Response Overview of the

McParland, Charles

2010-01-01T23:59:59.000Z

179

Automation in X-Ray Crystallography  

Science Journals Connector (OSTI)

Automation in X-Ray Crystallography ... But in the past few years, automation procedures have been applied to intrinsically superior experimental methods. ...

S.C. ABRAHAMS

1963-06-03T23:59:59.000Z

180

Understanding roi metrics for software test automation.  

E-Print Network [OSTI]

??Software test automation is widely accepted as an efficient software testing technique. However, automation has failed to deliver the expected productivity more often than not.… (more)

Jayachandran, Naveen

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Transportable automated ammonia sensor based on a pulsed thermoelectrically cooled  

E-Print Network [OSTI]

Transportable automated ammonia sensor based on a pulsed thermoelectrically cooled quantum single-frequency, thermoelectrically cooled, pulsed quantum-cascade laser with an embedded distributed absorption spectroscopy with a pulsed QC DFB laser was reported in Ref. 3, where wavelength modulation

182

Equipment  

Science Journals Connector (OSTI)

...circuit can be included which will return the system to its previous state when power has been restored after a power failure. (Panellit, Inc., Dept. 197) * AUXILIARY RECORKFR may be used with the manufacturer's infrared spectropho-tometers to provide...

JOSHUA STERN

1958-08-01T23:59:59.000Z

183

Equipment  

Science Journals Connector (OSTI)

...polarized d-c or a-c voltage, or insulation resistance. Range of voltage measurement...Milli-microsecond Time Interval measuring device. SPECIFICATIONS INPUT PULSE RANGE: 5 105v COUNT STORAGE...its use in any convenient location. (Thermal Dynamic Products Inc., Dept. 247...

JOSHUA STERN

1958-08-08T23:59:59.000Z

184

Opportunities for Automated Demand Response in Wastewater Treatment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Opportunities for Automated Demand Response in Wastewater Treatment Opportunities for Automated Demand Response in Wastewater Treatment Facilities in California - Southeast Water Pollution Control Plant Case Study Title Opportunities for Automated Demand Response in Wastewater Treatment Facilities in California - Southeast Water Pollution Control Plant Case Study Publication Type Report LBNL Report Number LBNL-6056E Year of Publication 2012 Authors Olsen, Daniel, Sasank Goli, David Faulkner, and Aimee T. McKane Date Published 12/2012 Publisher CEC/LBNL Keywords market sectors, technologies Abstract This report details a study into the demand response potential of a large wastewater treatment facility in San Francisco. Previous research had identified wastewater treatment facilities as good candidates for demand response and automated demand response, and this study was conducted to investigate facility attributes that are conducive to demand response or which hinder its implementation. One years' worth of operational data were collected from the facility's control system, submetered process equipment, utility electricity demand records, and governmental weather stations. These data were analyzed to determine factors which affected facility power demand and demand response capabilities.

185

Disposable and removable nucleic acid extraction and purification cartridges for automated flow-through systems  

DOE Patents [OSTI]

Removable cartridges are used on automated flow-through systems for the purpose of extracting and purifying genetic material from complex matrices. Different types of cartridges are paired with specific automated protocols to concentrate, extract, and purifying pathogenic or human genetic material. Their flow-through nature allows large quantities sample to be processed. Matrices may be filtered using size exclusion and/or affinity filters to concentrate the pathogen of interest. Lysed material is ultimately passed through a filter to remove the insoluble material before the soluble genetic material is delivered past a silica-like membrane that binds the genetic material, where it is washed, dried, and eluted. Cartridges are inserted into the housing areas of flow-through automated instruments, which are equipped with sensors to ensure proper placement and usage of the cartridges. Properly inserted cartridges create fluid- and air-tight seals with the flow lines of an automated instrument.

Regan, John Frederick

2014-09-09T23:59:59.000Z

186

Covered Product Category: Imaging Equipment  

Broader source: Energy.gov [DOE]

FEMP provides acquisition guidance and Federal efficiency requirements across a variety of product categories, including imaging equipment, which is covered by the ENERGY STAR® program. Federal laws and requirements mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law.

187

Equipment Certification Requirements | Open Energy Information  

Open Energy Info (EERE)

Equipment Certification Requirements Equipment Certification Requirements Jump to: navigation, search Policies requiring renewable energy equipment to meet certain standards serve to protect consumers from buying inferior equipment. These requirements not only benefit consumers; they also protect the renewable energy industry by making it more difficult for substandard systems to reach the market. [1] Contents 1 Equipment Certification Incentives 2 References Equipment Certification Incentives CSV (rows 1 - 19) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Canada Oil and Gas Operations Act (Canada) Environmental Regulations Equipment Certification Fees Generating Facility Rate-Making Generation Disclosure Industry Recruitment/Support Safety and Operational Guidelines

188

Laboratory Equipment & Supplies | Sample Preparation Laboratories  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Equipment & Supplies Equipment & Supplies John Bargar, SSRL Scientist Equipment is available to serve disciplines from biology to material science. All laboratories contain the following standard laboratory equipment: pH meters with standard buffers, analytical balances, microcentrifuges, vortex mixers, ultrasonic cleaning baths, magnetic stirrers, hot plates, and glassware. Most laboratories offer ice machines and cold rooms. Specialty storage areas for samples include a -80 freezer, argon and nitrogen glove boxes, radiation contamination areas, inert atmosphere chambers, and cold rooms. For specific information please see: Equipment Inventory Checkout Equipment & Supplies To view equipment inventory by laboratory, refer to the following pages: Biology Chemistry & Material Science Laboratory 1 Inventory

189

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Distribution Transformers Distribution Transformers Sign up for e-mail updates on regulations for this and other products A distribution transformer provides the final voltage transformation in the electric power distribution system by reducing the high voltage of electric current from a power line to a lower voltage for use in a building. The Department of Energy (DOE) has regulated the energy efficiency level of low-voltage dry-type distribution transformers since 2007, and liquid-immersed and medium-voltage dry-type distribution transformers since 2010. A distribution transformer designed and constructed to be mounted on a utility pole is referred to as a pole-mount transformer. A distribution transformer designed and constructed to be located at ground level or underground, mounted on a concrete pad, and locked in a steel case is referred to as a pad-mount transformer.

190

Home Network Technologies and Automating Demand Response  

SciTech Connect (OSTI)

Over the past several years, interest in large-scale control of peak energy demand and total consumption has increased. While motivated by a number of factors, this interest has primarily been spurred on the demand side by the increasing cost of energy and, on the supply side by the limited ability of utilities to build sufficient electricity generation capacity to meet unrestrained future demand. To address peak electricity use Demand Response (DR) systems are being proposed to motivate reductions in electricity use through the use of price incentives. DR systems are also be design to shift or curtail energy demand at critical times when the generation, transmission, and distribution systems (i.e. the 'grid') are threatened with instabilities. To be effectively deployed on a large-scale, these proposed DR systems need to be automated. Automation will require robust and efficient data communications infrastructures across geographically dispersed markets. The present availability of widespread Internet connectivity and inexpensive, reliable computing hardware combined with the growing confidence in the capabilities of distributed, application-level communications protocols suggests that now is the time for designing and deploying practical systems. Centralized computer systems that are capable of providing continuous signals to automate customers reduction of power demand, are known as Demand Response Automation Servers (DRAS). The deployment of prototype DRAS systems has already begun - with most initial deployments targeting large commercial and industrial (C & I) customers. An examination of the current overall energy consumption by economic sector shows that the C & I market is responsible for roughly half of all energy consumption in the US. On a per customer basis, large C & I customers clearly have the most to offer - and to gain - by participating in DR programs to reduce peak demand. And, by concentrating on a small number of relatively sophisticated energy consumers, it has been possible to improve the DR 'state of the art' with a manageable commitment of technical resources on both the utility and consumer side. Although numerous C & I DR applications of a DRAS infrastructure are still in either prototype or early production phases, these early attempts at automating DR have been notably successful for both utilities and C & I customers. Several factors have strongly contributed to this success and will be discussed below. These successes have motivated utilities and regulators to look closely at how DR programs can be expanded to encompass the remaining (roughly) half of the state's energy load - the light commercial and, in numerical terms, the more important residential customer market. This survey examines technical issues facing the implementation of automated DR in the residential environment. In particular, we will look at the potential role of home automation networks in implementing wide-scale DR systems that communicate directly to individual residences.

McParland, Charles

2009-12-01T23:59:59.000Z

191

Honeywell modular automation system acceptance test report  

SciTech Connect (OSTI)

This document provides the results of the Acceptance Test Procedure for the Honeywell Modular Automation System.

Cunningham, L.T., Westinghouse Hanford

1996-06-14T23:59:59.000Z

192

Automating the Selection of Fenestration Systems to Best Meet Daylighting  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Automating the Selection of Fenestration Systems to Best Meet Daylighting Automating the Selection of Fenestration Systems to Best Meet Daylighting Performance Goals Title Automating the Selection of Fenestration Systems to Best Meet Daylighting Performance Goals Publication Type Conference Paper LBNL Report Number LBNL-53003 Year of Publication 2003 Authors Fernandes, Luis L., and Konstantinos M. Papamichael Conference Name 2003 International Building Performance Simulation Association Conference Date Published 02/2003 Conference Location Eindhoven, Netherlands Call Number LBNL-53003 Abstract Traditional selection of fenestration systems follows a trial-and-error approach, i.e., iterative selection of fenestration systems and evaluation of their performance through the use of simulation tools and techniques. This paper is about the development of a new method, which inverts traditional practice, i.e., aims at automated selection of fenestration systems that best meet specific lighting performance goals. The new method is based on manipulation of matrices that represent the optical properties of fenestration systems, the propagation of light in interior spaces, and the outdoors luminous conditions. The method follows two steps: 1) the determination of the luminous flux distribution originating from the location of the fenestration that best meets the desired lighting performance goals and 2) the selection of the fenestration system that comes closer to producing the desired flux distribution from the outdoor daylight distribution.

193

Bulk Hauling Equipment for CHG  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

BULK HAULING EQUIPMENT FOR CHG BULK HAULING EQUIPMENT FOR CHG Don Baldwin Director of Product Development - Hexagon Lincoln HEXAGON LINCOLN TITAN(tm) Module System Compressed Hydrogen Gas * Capacity 250 bar - 616 kg 350 bar - 809 kg 540 bar - 1155 kg * Gross Vehicle Weight (with prime mover) 250 bar - 28 450 kg 350 bar - 30 820 kg 540 bar - 39 440 kg * Purchase Cost 250 bar - $510,000 350 bar - $633,750 540 bar - $1,100,000 Compressed Natural Gas * Capacity (250 bar at 15 C) - 7412 kg * GVW (With prime mover) - 35 250 kg * Purchase Cost (+/- 5%) - $510,000 HEXAGON LINCOLN TITAN(tm) V Magnum Trailer System Compressed Hydrogen Gas * Capacity 250 bar - 800 kg 350 bar - 1050 kg 540 bar - 1500 kg * Gross Vehicle Weight (with prime mover) 250 bar - 31 000 kg 350 bar - 34 200 kg 540 bar - 45 700 kg * Purchase Cost (+/-

194

BASIS Equipment | ORNL Neutron Sciences  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Equipment Equipment BASIS Schematic Schematic of the SNS Backscattering Spectrometer. Helium dewer cooling a sample Helium dewer cooling a sample (bird's eye view). The heart of the work in a typical experiment is setting up the sample in the desired environment. A typical neutron sample ranging from a millimeter to a few centimeters is placed in a specialized cylindrical can and sealed. For liquids, the backscattering instrument often uses an annular can, created by placing a smaller can within a larger can and inserting the liquid sample between the two cans. This picture shows a helium dewer cooling the environment encompassing the sample can, which has been lowered into the beam from the top of the scattering tank. Crystals Crystals. The backscattering spectrometer is defined by the reflection of specific

195

Football facility and equipment management  

Science Journals Connector (OSTI)

The paper investigates the subject of football facility and equipment management to present the key success factors and planning elements for consideration. The work is based on secondary data analysis and literature review, and the findings include both descriptive and prescriptive elements. The findings construct a theoretical basis for further development and provide football managers with explicit and practical advice on the subject. They further indicate that topics pertaining to football facility and equipment management are not and should not be viewed as independent tasks under a common umbrella. They are all part of a larger system with all aspects interrelated both at the planning and the operation stages. Moreover, they are found to be inextricably linked with the wider strategic and marketing processes and constitute a significant part of the value proposition of the club to its immediate customers, implicit customers, industry associates and wider society.

Nicos L. Kartakoullis; Alkis Thrassou; Demetris Vrontis; Thanos Kriemadis

2013-01-01T23:59:59.000Z

196

Used energy-related laboratory equipment grant program for institutions of higher learning. Eligible equipment catalog  

SciTech Connect (OSTI)

This is a listing of energy related equipment available through the Energy-Related Laboratory Equipment Grant Program which grants used equipment to institutions of higher education for energy-related research. Information included is an overview of the program, how to apply for a grant of equipment, eligibility requirements, types of equipment available, and the costs for the institution.

Not Available

1994-07-01T23:59:59.000Z

197

Distributed Intelligent Agents for Decision Making at Local Distributed  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Distributed Intelligent Agents for Decision Making at Local Distributed Distributed Intelligent Agents for Decision Making at Local Distributed Energy Resource (DER) Levels Speaker(s): David Cohen Date: June 3, 2005 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Peng Xu Our goals are to develop and commercialize a system of adaptive, intelligent software components which run at distributed locations (DER-level) on the energy network to improve the reliability, efficiency, and security of the U.S. electrical distribution network. We are developing GridAgents, an enabling software technology framework and platform using a distributed multi-agent systems approach for advanced communications and control capabilities (large- scale automated demand response, distribution automation control, and Microgrid control applications). For more

198

Method and apparatus for globally-accessible automated testing  

DOE Patents [OSTI]

A method and apparatus for sharing integrated testing services with a plurality of autonomous remote clients is disclosed. In the disclosed method, in response to an access request message, a process controller transmits an access enabling message to the remote client. The access enabling message includes instructions performable by a remote client to generate test equipment commands. A process controller interprets and transforms these commands into automated test instrument suite commands, which are provided to laboratory modules to perform the indicated tests. Test data results are then obtained and transmitted to the remote client.

Layne, Scott P. (Los Angeles, CA); Beugelsdijk, Tony J. (Los Alamos, NM)

1998-01-01T23:59:59.000Z

199

Automated Morphology Analysis of Nanoparticles  

E-Print Network [OSTI]

of this dissertation is to develop automated morphology analysis methods. Morphology analysis is comprised of three tasks: separate individual particles from an agglomerate of overlapping nano-objects (image segmentation); infer the particle's missing contours (shape...

Park, Chiwoo

2012-10-19T23:59:59.000Z

200

Aspects of automation mode confusion  

E-Print Network [OSTI]

Complex systems such as commercial aircraft are difficult for operators to manage. Designers, intending to simplify the interface between the operator and the system, have introduced automation to assist the operator. In ...

Wheeler, Paul H. (Paul Harrison)

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Technology modernization assessment flexible automation  

SciTech Connect (OSTI)

The objectives of this report are: to present technology assessment guidelines to be considered in conjunction with defense regulations before an automation project is developed to give examples showing how assessment guidelines may be applied to a current project to present several potential areas where automation might be applied successfully in the depot system. Depots perform primarily repair and remanufacturing operations, with limited small batch manufacturing runs. While certain activities (such as Management Information Systems and warehousing) are directly applicable to either environment, the majority of applications will require combining existing and emerging technologies in different ways, with the special needs of depot remanufacturing environment. Industry generally enjoys the ability to make revisions to its product lines seasonally, followed by batch runs of thousands or more. Depot batch runs are in the tens, at best the hundreds, of parts with a potential for large variation in product mix; reconfiguration may be required on a week-to-week basis. This need for a higher degree of flexibility suggests a higher level of operator interaction, and, in turn, control systems that go beyond the state of the art for less flexible automation and industry in general. This report investigates the benefits and barriers to automation and concludes that, while significant benefits do exist for automation, depots must be prepared to carefully investigate the technical feasibility of each opportunity and the life-cycle costs associated with implementation. Implementation is suggested in two ways: (1) develop an implementation plan for automation technologies based on results of small demonstration automation projects; (2) use phased implementation for both these and later stage automation projects to allow major technical and administrative risk issues to be addressed. 10 refs., 2 figs., 2 tabs. (JF)

Bennett, D.W.; Boyd, D.R.; Hansen, N.H.; Hansen, M.A.; Yount, J.A.

1990-12-01T23:59:59.000Z

202

The 'Problem' with Automation: Inappropriate Feedback and Interaction, not 'Over-Automation'  

Science Journals Connector (OSTI)

12 April 1990 research-article The 'Problem' with Automation: Inappropriate Feedback and Interaction, not 'Over-Automation' D. A. Norman As automation increasingly takes its place in industry, especially high risk industry...

1990-01-01T23:59:59.000Z

203

Type of automation failure: the effects on trust and reliance in automation.  

E-Print Network [OSTI]

??Past automation research has focused primarily on machine-related factors (e.g., automation reliability) and human-related factors (e.g., accountability). Other machine-related factors such as type of automation… (more)

Johnson, Jason D.

2004-01-01T23:59:59.000Z

204

Participation through Automation: Fully Automated Critical Peak Pricing in Commercial Buildings  

E-Print Network [OSTI]

Figure 2. Demand Response Automation Server and BuildingII system to notify the Automation Server of an up comingoccurs day-ahead). 2. The Automation Server posts two pieces

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

2006-01-01T23:59:59.000Z

205

Open Automated Demand Response for Small Commerical Buildings  

E-Print Network [OSTI]

of Fully Automated Demand  Response in Large Facilities.  Fully Automated Demand Response Tests in Large Facilities.  Open Automated  Demand Response Communication Standards: 

Dudley, June Han

2009-01-01T23:59:59.000Z

206

Scenarios for Consuming Standardized Automated Demand Response Signals  

E-Print Network [OSTI]

of Fully Automated Demand Response in Large Facilities.Fully Automated Demand Response Tests in Large Facilities.Interoperable Automated Demand Response Infrastructure.

Koch, Ed

2009-01-01T23:59:59.000Z

207

Automation World Features New White Paper on Wireless Security...  

Broader source: Energy.gov (indexed) [DOE]

Automation World Features New White Paper on Wireless Security Automation World Features New White Paper on Wireless Security The April 2009 issue of Automation World magazine...

208

Heating and Cooling System Support Equipment Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Heating and Cooling System Support Equipment Basics Heating and Cooling System Support Equipment Basics Heating and Cooling System Support Equipment Basics July 30, 2013 - 3:28pm Addthis Thermostats and ducts provide opportunities for saving energy. Dehumidifying heat pipes provide a way to help central air conditioners and heat pumps dehumidify air. Electric and gas meters allow users to track energy use. Thermostats Programmable thermostats can store and repeat multiple daily settings. Users can adjust the times heating or air-conditioning is activated according to a pre-set schedule. Visit the Energy Saver website for more information about thermostats and control systems in homes. Ducts Efficient and well-designed duct systems distribute air properly throughout a building, without leaking, to keep all rooms at a comfortable

209

Waste Heat Recovery from Industrial Process Heating Equipment -  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Waste Heat Recovery from Industrial Process Heating Equipment - Waste Heat Recovery from Industrial Process Heating Equipment - Cross-cutting Research and Development Priorities Speaker(s): Sachin Nimbalkar Date: January 17, 2013 - 11:00am Location: 90-2063 Seminar Host/Point of Contact: Aimee McKane Waste heat is generated from several industrial systems used in manufacturing. The waste heat sources are distributed throughout a plant. The largest source for most industries is exhaust / flue gases or heated air from heating systems. This includes the high temperature gases from burners in process heating, lower temperature gases from heat treat, dryers, and heaters, heat from heat exchangers, cooling liquids and gases etc. The previous studies and direct contact with the industry as well as equipment suppliers have shown that a large amount of waste heat is not

210

Automated Commissioning for Lower-cost, Widely Deployed Building Commissioning of the Future  

SciTech Connect (OSTI)

This chapter takes a brief look at the benefits of commissioning and describes a vision of the future where most of the objectives of commissioning will be accomplished automatically by capabilities built into the building systems themselves. Commissioning will become an activity that is performed continuously rather than periodically, and only repairs requiring replacement or overhaul of equipment will require manual intervention. This chapter then identifies some of the technologies that will be needed to realize this vision and ends with a call for all involved in the enterprise of building commissioning and automation to embrace and dedicate themselves to a future of automated commissioning.

Brambley, Michael R.; Katipamula, Srinivas

2011-08-16T23:59:59.000Z

211

Disciplined agility for process control & automation ; Disciplined agility for process control and automation .  

E-Print Network [OSTI]

??Process automation vendors must consider agility as a basis to gain a competitive edge in innovation. Process Automation systems can impact the operating cost of… (more)

Tibazarwa, Augustine

2009-01-01T23:59:59.000Z

212

Trust in automated systems the effect of automation level on trust calibration .  

E-Print Network [OSTI]

??Automated systems perform functions that were previously executed by a human. When using automation, the role of the human changes from operator to supervisor. For… (more)

Walliser, James C.

2011-01-01T23:59:59.000Z

213

Abatement of Air Pollution: Air Pollution Control Equipment and Monitoring Equipment Operation (Connecticut)  

Broader source: Energy.gov [DOE]

These regulations contain instructions for the operation and monitoring of air pollution control equipment, as well as comments on procedures in the event of equipment breakdown, failure, and...

214

Fire suppression and detection equipment  

SciTech Connect (OSTI)

Inspection and testing guidelines go beyond the 'Code of Federal Regulation'. Title 30 of the US Code of Federal Regulations (30 CFR) contains requirements and references to national standards for inspection, testing and maintenance of fire suppression and detection equipment for mine operators. However, federal requirements have not kept pace with national standards and best practices. The article lists National Fire Protection (NFPA) standards that are referenced by the US Mine Safety and Health Administration (MSHA) in 30 CFR. It then discusses other NFPA Standards excluded from 30 CFR and explains the NFPA standard development process. 2 refs., 3 tabs., 5 photos.

E.E. Bates [HSB Professional Loss Control, Lexington, KY (United States)

2006-01-15T23:59:59.000Z

215

Laboratory Equipment Donation Program - Application Process  

Office of Scientific and Technical Information (OSTI)

Equipment listings on the LEDP web site are obtained from the U.S. General Equipment listings on the LEDP web site are obtained from the U.S. General Services Administration (GSA) Energy Asset Disposal System (EADS). Once equipment is listed, EADS allows 30 days for grantees from eligible institutions to apply for it on the LEDP site. Equipment Condition Codes are found near the top of the "LEDP Equipment Information" page for each item. The condition of equipment is graded as follows: 1: Unused Good Condition 4: Used Good Condition 7: Repairable Requires Repairs X: Salvage Salvage S: Scrap Scrap Specific questions concerning equipment should be directed to the point of contact responsible for the item(s) under consideration. This information is listed on the "Equipment Information" page, as well as on the grant

216

INL Equipment to Aid Regional Response Team  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

INL Equipment to Aid Regional Response Team DOE-ID is transferring equipment to the Idaho Falls Police Department's Hazardous Materials Response Team for their use in responding to...

217

Operations and Maintenance for Major Equipment Types  

Broader source: Energy.gov [DOE]

Equipment lies at the heart of all operations and maintenance (O&M) activities. This equipment varies greatly across the Federal sector in age, size, type, model, condition, etc.

218

Dental CBCT equipment and performance issues  

Science Journals Connector (OSTI)

......time due to insufficient dose audit data. For dental CBCT equipment...there are no large-scale audits of equipment in clinical use...http://ec.europa.eu/energy/nuclear/radiation_protection...http://ec.europa.eu/energy/nuclear/radioprotection......

K. Horner; R. Jacobs; R. Schulze

2013-02-01T23:59:59.000Z

219

Consider Steam Turbine Drives for Rotating Equipment  

Broader source: Energy.gov [DOE]

This tip sheet outlines the benefits of steam turbine drives for rotating equipment as part of optimized steam systems.

220

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Low-Voltage Dry-Type Distribution Transformers Energy Conservation Standard Low-Voltage Dry-Type Distribution Transformers Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has completed a rulemaking to amend the current energy conservation standards for liquid-immersed, medium-voltage dry-type, and low-voltage dry-type distribution transformers. This activity is mandated by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule regarding amended energy efficiency standards for liquid-immersed, medium-voltage dry-type, and low-voltage dry-type distribution transformers. 78 FR 23335 (April 18, 2013). The distribution transformers final rule was the DOE's first "negotiated rulemaking," conducted under the Federal Advisory Committee Act and the Negotiated Rulemaking Act.

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Fact Sheet: Protecting Intelligent Distributed Power Grids Against Cyber Attacks  

Broader source: Energy.gov (indexed) [DOE]

Protecting Intelligent Distributed Protecting Intelligent Distributed Power Grids Against Cyber Attacks Development of a novel distributed and hierarchical security layer specific to intelligent grid design Intelligent power grids are interdependent energy management systems- encompassing generation, distribution, IT networks, and control systems-that use automated data analysis and demand response capabilities to increase system functionality, efficiency, and reliability. But increased interconnection and automation over a large geographical area requires a distributed and hierarchical approach to cyber security. This two-year project will develop three security components unique to intelligent power grids. The first is an automated

222

Proceedings: Tenth EPRI Substation Equipment Diagnostics Conference  

SciTech Connect (OSTI)

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The tenth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2002-06-01T23:59:59.000Z

223

Proceedings: Substation Equipment Diagnostics Conference IX  

SciTech Connect (OSTI)

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The ninth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2001-09-01T23:59:59.000Z

224

Proceedings: Substation Equipment Diagnostics Conference VIII  

SciTech Connect (OSTI)

Advanced monitoring and diagnostic sensors and systems are needed to provide reliable and accurate information for determining the condition of major transmission substation equipment. The eighth EPRI Substation Equipment Diagnostics Conference highlighted the work of researchers, universities, manufacturers, and utilities in producing advanced monitoring and diagnostic equipment for substations.

None

2000-06-01T23:59:59.000Z

225

Chapter 8 - Automation and Monitoring  

Science Journals Connector (OSTI)

This chapter begins with the topic of process automation which has the intent of making repetitive tasks more consistent, faster, and cheaper. As part of this discussion, we talk about how to determine if a process should be automated, how to document the process in preparation for automation, and how to perform the actual automation. A variety of scripting languages can be used to perform process automation and general best practices for scripting these processes is discussed as well as some thoughts on how to choose the right scripting language for the job. The second part of the chapter is all about monitoring of enterprise applications. Key performance indicators (KPIs) that give insight into the enterprise application’s performance over time as well as determining when to alert the enterprise applications administrator to potential problems within the application are discussed. Alerts are another important topic associated with enterprise application monitoring that is discussed including how to properly tune alerts through the selection of appropriate KPIs, retry counts, and retry intervals.

Jeremy Faircloth

2014-01-01T23:59:59.000Z

226

Event based Control for Distributed Systemsy  

E-Print Network [OSTI]

's wireless control systems Home automation Transportation networksHome automationIndustrial automation Home

Johansson, Karl Henrik

227

Solar Equipment Certification | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Equipment Certification Solar Equipment Certification Solar Equipment Certification < Back Eligibility Construction General Public/Consumer Savings Category Solar Buying & Making Electricity Heating & Cooling Water Heating Program Info State Florida Program Type Equipment Certification Provider Florida Solar Energy Center Under the Solar Energy Standards Act of 1976, the Florida Solar Energy Center (FSEC) is responsible for certifying all solar equipment sold in Florida. A manufacturer who wishes to have their solar equipment certified first contacts FSEC for an application and requests that FSEC test samples of the product at random. Equipment is then subjected to a series of tests in order to be approved or denied certification. Standards and applications procedures for specific technologies are available on the FSEC web site.

228

Laboratory Equipment Donation Program - Contact Us  

Office of Scientific and Technical Information (OSTI)

End of Year Reports End of Year Reports At the end of the first year of using LEDP grant equipment, the grantee must provide DOE with a report on the use of the equipment. If a grantee does not submit a report, the DOE OPMO who approved the grant application can pull the equipment back, or not allow that institution to apply for more equipment. The report should describe: Any new courses instituted as a result of the grant of the equipment; Existing courses which have been expanded as a result of the grant of the equipment; Research activities, e.g., thesis titles, journals articles, sponsored research, etc.; and Other ways the equipment has been used to enhance courses, e.g., experiments, demonstrations, etc. If your item control Number starts with Send your report to 890565

229

Automated Demand Response Opportunities in Wastewater Treatment Facilities  

E-Print Network [OSTI]

Interoperable Automated Demand Response Infrastructure,study of automated demand response in wastewater treatmentopportunities for demand response control strategies in

Thompson, Lisa

2008-01-01T23:59:59.000Z

230

Automation in image cytometry : continuous HCS and kinetic image cytometry  

E-Print Network [OSTI]

OF CALIFORNIA, SAN DIEGO Automation in Image Cytometry:xiv Abstract of Dissertation Automation in Image Cytometry:

Charlot, David J.

2012-01-01T23:59:59.000Z

231

Automation of Fluorous Solid-Phase Extraction for Parallel Synthesis  

Science Journals Connector (OSTI)

Automation of Fluorous Solid-Phase Extraction for Parallel Synthesis ... • Cartridge conditioning, sample loading, elution, and rinsing are automated. ...

Wei Zhang; Yimin Lu

2006-10-17T23:59:59.000Z

232

Open Automated Demand Response for Small Commerical Buildings  

E-Print Network [OSTI]

communications.    Automated Logic Model  Vendor  Load Type of the HVAC.   Automated Logic Model  Vendor  Load Type 

Dudley, June Han

2009-01-01T23:59:59.000Z

233

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Commercial and Industrial Pumps Commercial and Industrial Pumps Sign up for e-mail updates on regulations for this and other products Pumps are used in agriculture, oil and gas production, water and wastewater, manufacturing, mining, and commercial building systems. Currently there are no energy conservation standards for pumps. The Department of Energy (DOE) will conduct an analysis of the energy use, emissions, costs, and benefits associated with this equipment during the commercial and industrial pumps energy conservation standards rulemaking. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a notice of public meeting and availability of the framework document. 78 FR 7304 (Feb. 1, 2013). For more information, please see the rulemaking page.

234

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Commercial and Industrial Compressors Determination Commercial and Industrial Compressors Determination Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) proposes to determine that commercial and industrial compressors meet the criteria for covered equipment under Part A-1 of Title III of the Energy Policy and Conservation Act (EPCA), as amended. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a Proposed Coverage Determination concerning commercial and industrial compressors. 77 FR 76972 (Dec. 31, 2012). Public Meeting Information No public meeting is scheduled at this time. Submitting Public Comments The comment period is closed.

235

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Alternative Efficiency Determination Methods and Alternate Rating Methods Alternative Efficiency Determination Methods and Alternate Rating Methods Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) is proposing to revise and expand its existing regulations governing the use of alternative efficiency determination methods (AEDM) and alternate rating methods (ARM) for covered products as alternatives to testing for the purpose of certifying compliance. Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule revising its existing regulations governing the use of particular methods as alternatives to testing for commercial heating, ventilating, air conditioning, water heating, and refrigeration equipment. 78 FR 79579 (December 31, 2013).

236

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Illuminated Exit Signs Illuminated Exit Signs Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of illuminated exit signs since 2005. Illuminated exit signs are used to indicate exit doors in schools, hospitals, libraries, government buildings, and commercial buildings of all kinds, including offices, restaurants, stores, auditoriums, stadiums, and movie theatres. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates There are no recent updates for this equipment. Standards for Illuminated Exit Signs The following content summarizes the energy conservation standards for illuminated exit signs. The text is not an official reproduction of the Code of Federal Regulations and should not be used for legal research or citation.

237

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Commercial Warm Air Furnaces Commercial Warm Air Furnaces Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of commercial warm air furnaces since 1994. Commercial warm air furnaces are self-contained oil-fired or gas-fired furnaces that are designed to supply heated air through ducts to spaces that require it. Commercial warm air furnaces are industrial equipment and have a maximum rated input capacity of 225,000 British thermal units (Btu) an hour or more. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates DOE published a request for information regarding energy conservation standards for commercial warm air furnaces. 78 FR 25627 (May 2, 2013). For more information, please see the rulemaking webpage.

238

Appliance and Equipment Standards Program  

Broader source: Energy.gov [DOE]

The Building Technologies Office (BTO) implements minimum energy conservation standards for more than 50 categories of appliances and equipment. As a result of these standards, energy users saved about $55 billion on their utility bills in 2013. Since the beginning of 2009, 25 new or updated standards have been issued, which will help increase annual savings by more than 50 percent over the next decade. By 2030, cumulative operating cost savings from all standards in effect since 1987 will reach over $1.7 trillion, with a cumulative reduction of 6.8 billion tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of 1.4 billion automobiles. Products covered by standards represent about 90% of home energy use, 60% of commercial building use, and 29% of industrial energy us

239

An Analysis of Price Determination and Markups in the Air-Conditioning and Heating Equipment Industry  

SciTech Connect (OSTI)

In this report we calculate the change in final consumer prices due to minimum efficiency standards, focusing on a standard economic model of the air-conditioning and heating equipment (ACHE) wholesale industry. The model examines the relationship between the marginal cost to distribute and sell equipment and the final consumer price in this industry. The model predicts that the impact of a standard on the final consumer price is conditioned by its impact on marginal distribution costs. For example, if a standard raises the marginal cost to distribute and sell equipment a small amount, the model predicts that the standard will raise the final consumer price a small amount as well. Statistical analysis suggest that standards do not increase the amount of labor needed to distribute equipment the same employees needed to sell lower efficiency equipment can sell high efficiency equipment. Labor is a large component of the total marginal cost to distribute and sell air-conditioning and heating equipment. We infer from this that standards have a relatively small impact on ACHE marginal distribution and sale costs. Thus, our model predicts that a standard will have a relatively small impact on final ACHE consumer prices. Our statistical analysis of U.S. Census Bureau wholesale revenue tends to confirm this model prediction. Generalizing, we find that the ratio of manufacturer price to final consumer price prior to a standard tends to exceed the ratio of the change in manufacturer price to the change in final consumer price resulting from a standard. The appendix expands our analysis through a typical distribution chain for commercial and residential air-conditioning and heating equipment.

Dale, Larry; Millstein, Dev; Coughlin, Katie; Van Buskirk, Robert; Rosenquist, Gregory; Lekov, Alex; Bhuyan, Sanjib

2004-01-30T23:59:59.000Z

240

Process Control and Automation: The Bagrit Vision  

Science Journals Connector (OSTI)

Automation, broadly defined as the computer-assisted control of industrial processes, covers a wide spectrum of applications. Here we need to narrow the spectrum somewhat, so as to focus on the word automation as...

Emeritus Professor Simon Lavington

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Microcomputer Applications in Power System Substation Automation  

Science Journals Connector (OSTI)

The object of this chapter is to describe power system applications of microcomputers, particularly in the area of power substation automation.The major functions required in substation automation are reviewed an...

C. T. Nguyen; R. Grondin; A. St-Jacques…

1983-01-01T23:59:59.000Z

242

Home Automation with ZigBee  

Science Journals Connector (OSTI)

This article discusses a topic of home automation, also called domotics, and provides an ... advantages provided by ZigBee wireless networking standard for home automation solutions. ZigBee protocol implementatio...

Maxim Osipov

2008-01-01T23:59:59.000Z

243

Technical University of Denmark rsted DTU Automation  

E-Print Network [OSTI]

Technical University of Denmark �rsted · DTU Automation Project: SICAM - SIngle Conversion stage based SICAM using an LC-network Petar Ljusev, MSc., Ph.D. student, �rsted · DTU Automation e-mail: pl

244

Automated Operating Procedures for Transfer Limits  

E-Print Network [OSTI]

Automated Operating Procedures for Transfer Limits Final Project Report Power Systems Engineering · Illinois · Iowa State · Texas A&M · Washington State · Wisconsin Automated Operating Procedures

245

Automated Resoning in Modal Logics 0 (GENERAL PURPOSE) AUTOMATED REASONING IN MODAL LOGICS  

E-Print Network [OSTI]

Automated Resoning in Modal Logics 0 (GENERAL PURPOSE) AUTOMATED REASONING IN MODAL LOGICS BRANDEN FITELSON Department of Philosophy San Jos�e State University & Automated Reasoning Group.wisc.edu/fitelson BF @ AR @ MCS @ ANL & Philosophy @ SJSU May 16, 2002 Automated Resoning in Modal Logics 1

Fitelson, Branden

246

Automated Video-Based Fall Detection  

E-Print Network [OSTI]

home assistive monitoring uses technology such as sensors and cameras to aid live-alone aging persons, typically involving automation.

Edgcomb, Alex Daniel

2014-01-01T23:59:59.000Z

247

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Liquid-Immersed and Medium-Voltage Dry-type Distribution Transformers Energy Conservation Standard Liquid-Immersed and Medium-Voltage Dry-type Distribution Transformers Energy Conservation Standard Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has completed a rulemaking to amend the current energy conservation standards for liquid-immersed, medium voltage dry-type, and low-voltage dry-type distribution transformers. This activity is mandated by the Energy Policy and Conservation Act (EPCA). Recent Updates | Public Meeting Information | Submitting Public Comments | Milestones and Documents | Related Rulemakings | Statutory Authority | Contact Information Recent Updates DOE published a final rule regarding amended energy efficiency standards for liquid-immersed, medium-voltage dry-type, and low-voltage dry-type distribution transformers. 78 FR 23335 (April 18, 2013). The distribution transformers final rule was the DOE's first "negotiated rulemaking," conducted under the Federal Advisory Committee Act and the Negotiated Rulemaking Act.

248

Protecting Intelligent Distributed Power Grids Against Cyber Attacks - May  

Broader source: Energy.gov (indexed) [DOE]

Protecting Intelligent Distributed Power Grids Against Cyber Protecting Intelligent Distributed Power Grids Against Cyber Attacks - May 2008 Protecting Intelligent Distributed Power Grids Against Cyber Attacks - May 2008 Development of a novel distributed and hierarchical security layer specific to intelligent grid design will help protect intelligent distributed power grids from cyber attacks. Intelligent power grids are interdependent energy management systems-encompassing generation, distribution, IT networks, and control systems-that use automated data analysis and demand response capabilities to increase system functionality, efficiency, and reliability. But increased interconnection and automation over a large geographical area requires a distributed and hierarchical approach to cybersecurity. Protecting Intelligent Distributed Power Grids Again Cyber Attacks.pdf

249

Early Markets: Fuel Cells for Material Handling Equipment | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Material Handling Equipment Early Markets: Fuel Cells for Material Handling Equipment This fact sheet describes the use of hydrogen fuel cells to power material handling equipment...

250

Step 5b: Help Program Contractors Obtain the Necessary Equipment...  

Broader source: Energy.gov (indexed) [DOE]

b: Help Program Contractors Obtain the Necessary Equipment Step 5b: Help Program Contractors Obtain the Necessary Equipment In addition to equipment for installing energy...

251

Operations and Maintenance for Major Equipment Types | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Types Operations and Maintenance for Major Equipment Types Equipment lies at the heart of all operations and maintenance (O&M) activities. This equipment varies greatly...

252

Technical Report TRARP1695 Automated Reasoning Project  

E-Print Network [OSTI]

Technical Report TR­ARP­16­95 Automated Reasoning Project Research School of Information Sciences Heuerding Automated Institute for Applied Mathematics Reasoning Project and Computer Science ANU University that contains automated proof procedures based on modal Gentzen systems for numerous propositional (nonclassical

Goré, Rajeev

253

AUTOMATED CRITICAL PEAK PRICING FIELD TESTS  

E-Print Network [OSTI]

AUTOMATED CRITICAL PEAK PRICING FIELD TESTS: 2006 PROGRAM DESCRIPTION AND RESULTS) for development of the DR Automation Server System This project could not have been completed without extensive: Greg Watson and Mark Lott · C&C Building Automation: Mark Johnson and John Fiegel · Chabot Space

254

INTEGRATING AUTOMATION DESIGN INFORMATION WITH XML  

E-Print Network [OSTI]

INTEGRATING AUTOMATION DESIGN INFORMATION WITH XML Mika Viinikkala, Seppo Kuikka Institute of Automation and Control, Tampere University of Technology, P.O. Box 692, 33101 Tampere, Finland Email: mika.viinikkala@tut.fi, seppo.kuikka@tut.fi Keywords: Systems integration, XML, automation design Abstract: This paper presents

255

TAMPERE UNIVERSITY OF TECHNOLOGY DEPARTMENT OF AUTOMATION  

E-Print Network [OSTI]

TAMPERE UNIVERSITY OF TECHNOLOGY DEPARTMENT OF AUTOMATION An Intelligent Web Service for Operation 2004 Examiner: Prof. Seppo Kuikka #12;2 Abstract TAMPERE UNIVERSITY OF TECHNOLOGY Automation Degree Program Institute of Automation and Control Jaakkola, Veli-Pekka: An Intelligent Web Service for Operation

256

Automating Shallow Seismic Imaging  

SciTech Connect (OSTI)

This seven-year, shallow-seismic reflection research project had the aim of improving geophysical imaging of possible contaminant flow paths. Thousands of chemically contaminated sites exist in the United States, including at least 3,700 at Department of Energy (DOE) facilities. Imaging technologies such as shallow seismic reflection (SSR) and ground-penetrating radar (GPR) sometimes are capable of identifying geologic conditions that might indicate preferential contaminant-flow paths. Historically, SSR has been used very little at depths shallower than 30 m, and even more rarely at depths of 10 m or less. Conversely, GPR is rarely useful at depths greater than 10 m, especially in areas where clay or other electrically conductive materials are present near the surface. Efforts to image the cone of depression around a pumping well using seismic methods were only partially successful (for complete references of all research results, see the full Final Technical Report, DOE/ER/14826-F), but peripheral results included development of SSR methods for depths shallower than one meter, a depth range that had not been achieved before. Imaging at such shallow depths, however, requires geophone intervals of the order of 10 cm or less, which makes such surveys very expensive in terms of human time and effort. We also showed that SSR and GPR could be used in a complementary fashion to image the same volume of earth at very shallow depths. The primary research focus of the second three-year period of funding was to develop and demonstrate an automated method of conducting two-dimensional (2D) shallow-seismic surveys with the goal of saving time, effort, and money. Tests involving the second generation of the hydraulic geophone-planting device dubbed the ''Autojuggie'' showed that large numbers of geophones can be placed quickly and automatically and can acquire high-quality data, although not under rough topographic conditions. In some easy-access environments, this device could make SSR surveying considerably more efficient and less expensive, particularly when geophone intervals of 25 cm or less are required. The most recent research analyzed the difference in seismic response of the geophones with variable geophone spike length and geophones attached to various steel media. Experiments investigated the azimuthal dependence of the quality of data relative to the orientation of the rigidly attached geophones. Other experiments designed to test the hypothesis that the data are being amplified in much the same way that an organ pipe amplifies sound have so far proved inconclusive. Taken together, the positive results show that SSR imaging within a few meters of the earth's surface is possible if the geology is suitable, that SSR imaging can complement GPR imaging, and that SSR imaging could be made significantly more cost effective, at least in areas where the topography and the geology are favorable. Increased knowledge of the Earth's shallow subsurface through non-intrusive techniques is of potential benefit to management of DOE facilities. Among the most significant problems facing hydrologists today is the delineation of preferential permeability paths in sufficient detail to make a quantitative analysis possible. Aquifer systems dominated by fracture flow have a reputation of being particularly difficult to characterize and model. At chemically contaminated sites, including U.S. Department of Energy (DOE) facilities and others at Department of Defense (DOD) installations worldwide, establishing the spatial extent of the contamination, along with the fate of the contaminants and their transport-flow directions, is essential to the development of effective cleanup strategies. Detailed characterization of the shallow subsurface is important not only in environmental, groundwater, and geotechnical engineering applications, but also in neotectonics, mining geology, and the analysis of petroleum reservoir analogs. Near-surface seismology is in the vanguard of non-intrusive approaches to increase knowledge of the shallow subsurface; our

Steeples, Don W.

2004-12-09T23:59:59.000Z

257

Chapter 13 - Commercial Building Automation  

Science Journals Connector (OSTI)

A Building Automation System (BAS) is a computerized, intelligent system that controls and measures lighting, climate, security, and other mechanical and electrical systems in a building. The purpose of a BAS is typically to reduce energy and maintenance costs, as well as to increase control, comfort, reliability, and ease of use for maintenance staff and tenants.

Jan Höller; Vlasios Tsiatsis; Catherine Mulligan; Stamatis Karnouskos; Stefan Avesand; David Boyle

2014-01-01T23:59:59.000Z

258

Automated computation meets hot QCD  

E-Print Network [OSTI]

We give a short review on recent progress in the field of automated calculations in finite-temperature field theory, where integration-by-parts techniques have proven (almost) as useful as in the zero-temperature case. Furthermore, we provide one concrete example of an evaluation of a new three-loop master sum-integral that exhibits maximal divergence.

Ioan Ghisoiu; York Schroder

2012-10-19T23:59:59.000Z

259

ALMS: Automated logic mapping system  

Science Journals Connector (OSTI)

ALMS is a set of design automation computer programs which accepts as input a description of a logic design, specifications of modules (e.g., chips, cards, etc.) into which the blocks of the design are to be partitioned or mapped, and some constraints ...

R. L. Russo; P. K. Wolff, Sr.

1971-06-01T23:59:59.000Z

260

Better Buildings Alliance Equipment Performance Specifications  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

BBA Equipment Performance BBA Equipment Performance Specifications William Goetzler Navigant Consulting william.goetzler@navigant.com (781) 270 8351 April 4, 2013 Better Buildings Alliance BTO Program Review 2 | Building Technologies Office eere.energy.gov Project Overview The BBA Performance Specifications project provides information and tools to help BBA members and other commercial building owners/operators specify and purchase high efficiency equipment. - Ensures targeted technologies are of interest to end users and manufacturers

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Better Buildings Alliance Equipment Performance Specifications  

Broader source: Energy.gov (indexed) [DOE]

BBA Equipment Performance BBA Equipment Performance Specifications William Goetzler Navigant Consulting william.goetzler@navigant.com (781) 270 8351 April 4, 2013 Better Buildings Alliance BTO Program Review 2 | Building Technologies Office eere.energy.gov Project Overview The BBA Performance Specifications project provides information and tools to help BBA members and other commercial building owners/operators specify and purchase high efficiency equipment. - Ensures targeted technologies are of interest to end users and manufacturers

262

Sound quality descriptors for HVAC equipment from ARI Standards  

Science Journals Connector (OSTI)

The Air Conditioning and Refrigeration Institute (ARI) has several standards that provide methods to evaluate the sound quality of heating ventilating and air?conditioning (HVAC) equipment. These include Standard 270 Sound rating of outdoor unitary equipment Standard 350 Sound rating of non?ducted indoor air?conditioning equipment and Standard 1140P Procedures for evaluating sound quality of HVAC equipment. The preferred method in these standards is best described in Standard 1140P which uses one?third octave band sound power levels that are weighted to adjust for the sensitivity to frequency distribution and presence of tones and are then converted to a single number sound quality indicator. The tone adjustment is based on the projection of a given one?third octave band level relative to the average of the adjacent one?third octave bands. An alternate use of Zwicker method B to determine loudness and loudness level is also provided in ARI Standard 1140P. These standards provide a convenient method by which complex sounds for similar products may be compared.

2003-01-01T23:59:59.000Z

263

Solar Equipment Certification | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Solar Equipment Certification Solar Equipment Certification Solar Equipment Certification < Back Eligibility Commercial Construction Installer/Contractor Residential Savings Category Heating & Cooling Commercial Heating & Cooling Solar Heating Water Heating Program Info State Minnesota Program Type Equipment Certification Provider Minnesota Department of Commerce Minnesota law requires that all active solar space-heating and water-heating systems, sold, offered for sale, or installed on residential and commercial buildings in the state meet Solar Rating and Certification Corporation (SRCC) standards. Specifically, the rule references SRCC's "Operating Guidelines" pertaining to collector certification and system certification: OG-100 and OG-300, respectively. Local building officials

264

G129 S129 Equipment List Windbreaker  

E-Print Network [OSTI]

(optional) Water shoes (tevas or old tennis shoes) Gaitors (optional) COURSE EQUIPMENT*: Pocket or wrist operated) Bug Spray Deck of cards, musical instrument, Frisbee, etc (optional) * Textbooks should

Polly, David

265

PPP Equipment Corporation | Open Energy Information  

Open Energy Info (EERE)

Name: PPP Equipment Corporation Sector: Solar Product: PPP-E designs, produces and markets Chemical Vapor Deposition (CVD) reactors and converter systems producing high-purity...

266

Healthcare Energy: Spotlight on Medical Equipment  

Broader source: Energy.gov [DOE]

The Building Technologies Office conducted a healthcare energy end-use monitoring project for two sites. Read details about large medical imaging equipment energy results.

267

Best Management Practice #11: Commercial Kitchen Equipment |...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

savings. Water-using commercial kitchen equipment include pre-rinse spray valves, wash tanks and sinks, commercial dishwashers, food steamers, steam kettles, commercial ice...

268

Equips Nucleares SA | Open Energy Information  

Open Energy Info (EERE)

SA Place: Madrid, Spain Zip: 28006 Sector: Services Product: ENSA is a Spanish nuclear components and nuclear services supply company. References: Equips Nucleares, SA1...

269

MOV surge arresters: improved substation equipment protection  

SciTech Connect (OSTI)

The introduction of metal-oxide-varistor (MOV) surge arresters has added a new dimension to substation equipment protection. Through the optimal use of these arresters, it is possible to lower surge arrester ratings and thereby improve protective margins, resulting in a possible reduction of the insulation levels (BIL) of substation equipment. This reduction in BIL can lead to a significant reduction in the cost of substation equipment. General methods are delineated for selecting MOV surge arresters for substation protection and the resulting effect on substation equipment insulation levels.

Niebuhr, W.D.

1985-07-01T23:59:59.000Z

270

Reduce Radiation Losses from Heating Equipment  

Broader source: Energy.gov [DOE]

This tip sheet describes how to save process heating energy and costs by reducing expensive heat losses from industrial heating equipment, such as furnaces.

271

WEAR RESISTANT ALLOYS FOR COAL HANDLING EQUIPMENT  

E-Print Network [OSTI]

Proceedings of the Conference on Coal Feeding Systems, HeldWear Resistant Alloys for Coal Handling Equipment", proposalWear Resistant Alloys for Coal Handling Equi pment". The

Bhat, M.S.

2011-01-01T23:59:59.000Z

272

Computers, Electronics and Electrical Equipment (2010 MECS) ...  

Energy Savers [EERE]

Electronics and Electrical Equipment More Documents & Publications MECS 2006 - Computer, Electronics and Appliances Cement (2010 MECS) Glass and Glass Products (2010 MECS)...

273

Rockwell Automation - Owens Corning Teaming Profile  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rockwell Automation Owens Corning Rockwell Automation Owens Corning 1201 S. Second Street 247 York Road Milwaukee, WI 53204 Guelph, Ontario N1E 3G4 Business: Industrial Automation Business: Textile / Fiber Nigel Hitchings Frank Peel Marketing Manager Electrical Support Specialist Phone: 508-357-8404 Phone: 519-823-7208 Email: nehitchings@ra.rockwell.com Email: frank.peel@owenscorning.com Owens Corning partners with Rockwell Automation to retrofit fans with VFDs, saving $67,000 annually Project Scope Owens Corning and Rockwell Automation installed Variable Frequency Drives (VFDs) on one 125HP cooling fan and three 40HP recirculation fans at the Owens Corning Guelph Glass Plant. The VFDs were integrated with the existing Rockwell Automation programmable automation controller to collect

274

Facilities Automation and Energy Management  

E-Print Network [OSTI]

capabilities can help pinpoint the equipment performance level and variations. The arithmetic and logic capabilities can be used to generate sophisticated and interactive control strategies. The communications capabilities provide management information...

Jen, D. P.

1983-01-01T23:59:59.000Z

275

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Furnaces and Boilers Residential Furnaces and Boilers Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of residential furnaces and boilers since 1987. Residential furnaces and boilers include gas, electric, and oil-fired furnaces and boilers that are used to provide central heating to residential dwellings. Furnaces heat air and distribute the heated air through the house using ducts. Boilers heat water, providing either hot water or steam for heating. Steam is distributed via pipes to steam radiators, and hot water can either be distributed via baseboard radiators, radiant floor systems, or can heat air via a coil. The standards for residential furnaces and boilers implemented in 1992 will save approximately 3.9 quads of energy and result in approximately $46.2 billion in energy bill savings for products shipped from 1992-2021. The standard will avoid about 206 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 40.4 million automobiles.

276

Specimen coordinate automated measuring machine/fiducial automated measuring machine  

SciTech Connect (OSTI)

The Specimen coordinate Automated Measuring Machine (SCAMM) and the Fiducial Automated Measuring Machine (FAMM) is a computer controlled metrology system capable of measuring length, width, and thickness, and of locating fiducial marks. SCAMM and FAMM have many similarities in their designs, and they can be converted from one to the other without taking them out of the hot cell. Both have means for: supporting a plurality of samples and a standard; controlling the movement of the samples in the +/- X and Y directions; determining the coordinates of the sample; compensating for temperature effects; and verifying the accuracy of the measurements and repeating as necessary. SCAMM and FAMM are designed to be used in hot cells.

Hedglen, Robert E. (Bethel Park, PA); Jacket, Howard S. (Pittsburgh, PA); Schwartz, Allan I. (Turtle Creek, PA)

1991-01-01T23:59:59.000Z

277

Safeguarding Equipment and Protecting Employees from  

E-Print Network [OSTI]

Safeguarding Equipment and Protecting Employees from Amputations www.osha.gov Small Business Safety of Labor for Occupational Safety and Health #12;Safeguarding Equipment and Protecting Employees from Activities 9 Hazard Analysis 9 Controlling Amputation Hazards 9 Safeguarding Machinery 9 Primary Safeguarding

Colton, Jonathan S.

278

Electrical Equipment Inspection Program Electrical Safety  

E-Print Network [OSTI]

Electrical Equipment Inspection Program Electrical Safety SLAC-I-730-0A11A-001-R003 23 March 2005 Document Title: Electrical Equipment Inspection Program Original Publication Date: 19 January 2005 Revised Publication Date: 23 March 2005 (updated 29 November 2010) Department: Electrical Safety Document Number: SLAC

Wechsler, Risa H.

279

Office equipment energy use and trends  

SciTech Connect (OSTI)

Office information technologies are using an increasing amount of energy in commercial buildings. During recent forecasting hearings in California, the office equipment end use has been a major source of differences among forecasts of commercial sector energy use. Not only are there major differences in forecasted load growth resulting from the energy use of office equipment, but there are also differences in interpretations of historical and base-year estimates. Understanding office equipment energy use is particularly important because office equipment is widely believed to be the fastest growing electrical end use in the fastest growing sector. This report describes the development and application of a spreadsheet to estimate current and future energy use by office equipment. We define the term ``office equipment`` to mean information processing technologies used in buildings. The seven categories of office equipment relate to categories found in our analysis of utility surveys and industry sales reports. These seven categories of equipment are examined for eleven types of commercial buildings.

Piette, M.A.; Eto, J.H.; Harris, J.P.

1991-09-01T23:59:59.000Z

280

Office equipment energy use and trends  

SciTech Connect (OSTI)

Office information technologies are using an increasing amount of energy in commercial buildings. During recent forecasting hearings in California, the office equipment end use has been a major source of differences among forecasts of commercial sector energy use. Not only are there major differences in forecasted load growth resulting from the energy use of office equipment, but there are also differences in interpretations of historical and base-year estimates. Understanding office equipment energy use is particularly important because office equipment is widely believed to be the fastest growing electrical end use in the fastest growing sector. This report describes the development and application of a spreadsheet to estimate current and future energy use by office equipment. We define the term office equipment'' to mean information processing technologies used in buildings. The seven categories of office equipment relate to categories found in our analysis of utility surveys and industry sales reports. These seven categories of equipment are examined for eleven types of commercial buildings.

Piette, M.A.; Eto, J.H.; Harris, J.P.

1991-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Testing of complex IEC 61850 based substation automation systems  

Science Journals Connector (OSTI)

The integration of multifunctional intelligent substation devices (ISDs), in complex substation or power plant automation systems, requires the development of methods and tools for their testing that will ensure the correct operation of protection, control, monitoring, recording and metering functions, under normal and abnormal system conditions. The new IEC 61850 standard for communication networks and systems in substations allows the development of high-speed peer-to-peer communications based distributed applications, based on multicast of status changes or sampled analogue values. This paper details the requirements for the testing of complex substation automation systems. The testing methods need to correspond to the functional hierarchy of the substation automation system. Functional element testing, integration and system testing are discussed. Systems with Substation Bus only, and with both Process Bus and Substation Bus, are considered. A method for the testing of both types of system is proposed, based on a specific order of system components testing. Solutions for the testing of the individual components of the IEC 61850 based system, as well as for the testing of distributed applications, are described at the end of the paper.

Alexander Apostolov

2008-01-01T23:59:59.000Z

282

Definition: Equipment Health Sensor | Open Energy Information  

Open Energy Info (EERE)

Sensor Sensor Jump to: navigation, search Dictionary.png Equipment Health Sensor Monitoring devices that automatically measure and communicate equipment characteristics that are related to the 'health' and maintenance of the equipment. These characteristics can include, but are not limited to temperature, dissolved gas, and loading. These devices can also automatically generate alarm signals if the equipment characteristics reach critical or dangerous levels.[1] Related Terms sustainability References ↑ [www.smartgrid.gov/sites/default/files/pdfs/description_of_assets.pdf SmartGrid.gov 'Description of Assets'] An LikeLike UnlikeLike You like this.Sign Up to see what your friends like. inline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Health_Sensor&oldid=502526

283

Registration, Force Protection Equipment Demonstration - May 2009 |  

Broader source: Energy.gov (indexed) [DOE]

Registration, Force Protection Equipment Demonstration - May 2009 Registration, Force Protection Equipment Demonstration - May 2009 Registration, Force Protection Equipment Demonstration - May 2009 May 2009 Demonstrating commercially availale physical security/force protection soultions around the world The bombing of Khobar Towers in Saudi Arabia on 25 June 1996 revealed the need for continal vigilance and protection againist terrorist forces intent on harming US personnel and interests. The Chairman if the Joint Chiefs of Staff directed the Services to investigate COTS equipments solutions for physical security/force protection needs. The Office of the Under Secretary of Defense for Acquistion, Technology, and Logistics (OUSD {at&l}) tasked the Office of the US Army Product Manager, force Protection Systems (PM-FPS), to coordiante and facilitate a Force Protection Equipment

284

RMOTC - Field Information - Equipment and Facilities  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Equipment & Facilities Equipment & Facilities Motor Grader at RMOTC Notice: As of July 15th 2013, the Department of Energy announced the intent to sell Naval Petroleum Reserve Number 3 (NPR3). The sale of NPR-3 will also include the sale of all equipment and materials onsite. A decision has been made by the Department of Energy to complete testing at RMOTC by July 1st, 2014. RMOTC will complete testing in the coming year with the currently scheduled testing partners. For more information on the sale of NPR-3 and sale of RMOTC equipment and materials please join our mailing list here. RMOTC's test facility has its own line of workover, support, and heavy equipment available for partner use on site. RMOTC can also offer its partners workspace on site in its Customer Operations Center which has

285

Office Buildings - End-Use Equipment  

U.S. Energy Information Administration (EIA) Indexed Site

End-Use Equipment End-Use Equipment The types of space heating equipment used in office buildings were similar to those of the commercial buildings sector as a whole (Table 8 and Figure 5). Furnaces were most used followed by packaged heating systems. Individual space heaters were third-most used but were primarily used to supplement the building's main heating system. Boilers and district heat systems were more often used in larger buildings. Table 8. Types of Heating Equipment Used in Office Buildings, 2003 Number of Buildings (thousand) Total Floorspace (million square feet) All Buildings* All Office Buildings All Buildings* All Office Buildings All Buildings 4,645 824 64,783 12,208 All Buildings with Space Heating 3,982 802 60,028 11,929 Heating Equipment (more than one may apply)

286

CVD Equipment Corp | Open Energy Information  

Open Energy Info (EERE)

CVD Equipment Corp CVD Equipment Corp Jump to: navigation, search Name CVD Equipment Corp Place Ronkonkoma, New York Zip 11779 Sector Solar Product New York-based maker of chemical vapour deposition process equipment. This equipment is used in the manufacture of solar and semiconductor fabrication. Coordinates 40.81122°, -73.098744° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.81122,"lon":-73.098744,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

287

Definition: Disturbance Monitoring Equipment | Open Energy Information  

Open Energy Info (EERE)

Disturbance Monitoring Equipment Disturbance Monitoring Equipment Jump to: navigation, search Dictionary.png Disturbance Monitoring Equipment Devices capable of monitoring and recording system data pertaining to a Disturbance. Such devices include the following categories of recorders: Sequence of event recorders which record equipment response to the event., Fault recorders, which record actual waveform data replicating the system primary voltages and currents. This may include protective relays., Dynamic Disturbance Recorders (DDRs), which record incidents that portray power system behavior during dynamic events such as low-frequency (0.1 Hz - 3 Hz) oscillations and abnormal frequency or voltage excursions. Phasor Measurement Units and any other equipment that meets the functional requirements of DMEs may qualify as DMEs.[1]

288

Laboratory Equipment Donation Program - About Us  

Office of Scientific and Technical Information (OSTI)

About LEDP About LEDP The Laboratory Equipment Donation Program (LEDP), formerly the Energy-Related Laboratory Equipment (ERLE) Grant Program, was established by the United States Department of Energy (DOE) to grant surplus and available used energy-related laboratory equipment to universities and colleges in the United States for use in energy oriented educational programs. This grant program is sponsored by the Office of Workforce Development for Teachers and Scientists (WDTS). The listing of equipment available through LEDP is updated as new equipment is identified. It is available at no cost for a limited time and is granted on a first-received qualified application basis. Specific items may be recalled for DOE use and become unavailable through the program after the

289

Automatic monitoring of vibration welding equipment  

DOE Patents [OSTI]

A vibration welding system includes vibration welding equipment having a welding horn and anvil, a host device, a check station, and a robot. The robot moves the horn and anvil via an arm to the check station. Sensors, e.g., temperature sensors, are positioned with respect to the welding equipment. Additional sensors are positioned with respect to the check station, including a pressure-sensitive array. The host device, which monitors a condition of the welding equipment, measures signals via the sensors positioned with respect to the welding equipment when the horn is actively forming a weld. The robot moves the horn and anvil to the check station, activates the check station sensors at the check station, and determines a condition of the welding equipment by processing the received signals. Acoustic, force, temperature, displacement, amplitude, and/or attitude/gyroscopic sensors may be used.

Spicer, John Patrick; Chakraborty, Debejyo; Wincek, Michael Anthony; Wang, Hui; Abell, Jeffrey A; Bracey, Jennifer; Cai, Wayne W

2014-10-14T23:59:59.000Z

290

Universal null DTE (data terminal equipment)  

DOE Patents [OSTI]

A communication device in the form of data terminal equipment permits two data communication equipments, each having its own master clock and operating at substantially the same nominal clock rate, to communicate with each other in a multi-segment circuit configuration of a general communication network even when phase or frequency errors exist between the two clocks. Data transmitted between communication equipments of two segments of the communication network is buffered. A variable buffer fill circuit is provided to fill the buffer to a selectable extent prior to initiation of data output clocking. Selection switches are provided to select the degree of buffer preload. A dynamic buffer fill circuit may be incorporated for automatically selecting the buffer fill level as a function of the difference in clock frequencies of the two equipments. Controllable alarm circuitry is provided for selectively generating an underflow or an overflow alarm to one or both of the communicating equipments. 5 figs.

George, M.; Pierson, L.G.; Wilkins, M.E.

1987-11-09T23:59:59.000Z

291

Definition: Equipment Condition Monitor | Open Energy Information  

Open Energy Info (EERE)

Condition Monitor Condition Monitor Jump to: navigation, search Dictionary.png Equipment Condition Monitor A monitoring device that automatically measures and communicates equipment characteristics that are related to the "health" and maintenance of the equipment. These characteristics can include, but are not limited to temperature, dissolved gas, and loading. These devices can automatically generate alarm signals if conditions exceed preset thresholds.[1] Related Terms sustainability References ↑ https://www.smartgrid.gov/category/technology/equipment_condition_monitor [[C LikeLike UnlikeLike You like this.Sign Up to see what your friends like. ategory: Smart Grid Definitions|Template:BASEPAGENAME]] Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Condition_Monitor&oldid=502601"

292

Automated Export Control.PDF  

Broader source: Energy.gov (indexed) [DOE]

3 3 I N S P E C T I O N R E P O R T U.S. DEPARTMENT OF ENERGY OFFICE OF INSPECTOR GENERAL OFFICE OF INSPECTIONS INSPECTION OF THE DEPARTMENT OF ENERGY'S AUTOMATED EXPORT CONTROL SYSTEM DECEMBER 2001 U.S. DEPARTMENT OF ENERGY Washington, DC 20585 December 7, 2001 MEMORANDUM FOR THE SECRETARY FROM: Gregory H. Friedman /s/ Inspector General SUBJECT: INFORMATION: Report on "Inspection of the Department of Energy's Automated Export Control System" BACKGROUND The National Defense Authorization Act for Fiscal Year 2000 (NDAA for FY 2000) contained a provision that not later than March 30 of each year the President will submit to Congress, beginning in the year 2000 and ending in the year 2007, an annual report on the Government's policies and procedures with respect to the export of technologies and technical information with

293

Automated Transportation Management System (ATMS)  

Broader source: Energy.gov (indexed) [DOE]

Re evised June 2010 Re evised June 2010 Autom The Depa Transport an integra system al outbound air. Its ea 1989 DOE significant operationa commerce electronic rates, pre transporta users eva shipments opportunit logistics im ATMS is i radioactiv shipments System ATMS is a activities p packaging including materials. common s lading, fre * W * C S * A * H * E * * O 0 mated T artment of Ene tation Manage ated web-base lowing users freight shipm arly developm E Inspector G t opportunitie al efficiency t e. Today's sy cally prepare s pare shipping ation bills befo aluate carrier s, and use co ties for system mprovements ts capability t ve and other h s in a comple Modules a modular sys performed by g and transpo radioactive a . Its modules shipment info eight bills, rate System Web Applic Carrier Eval Selection Automated

294

Definition: Automated Voltage And Var Control | Open Energy Information  

Open Energy Info (EERE)

Voltage And Var Control Voltage And Var Control Jump to: navigation, search Dictionary.png Automated Voltage And Var Control Automated voltage and VAR control requires coordinated operation of reactive power resources such as capacitor banks, voltage regulators, transformer load-tap changers, and distributed generation (DG) with sensors, controls, and communications systems. These devices could operate autonomously in response to local events or in response to signals from a central control system.[1] View on Wikipedia Wikipedia Definition Also Known As Volt-VAR Control (VVC) Related Terms smart grid, Reactive Power References ↑ SmartGrid.gov 'Description of Functions' An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from

295

Convection automated logic oven control  

SciTech Connect (OSTI)

For the past few years, there has been a greater push to bring more automation to the cooling process. There have been attempts at automated cooking using a wide range of sensors and procedures, but with limited success. The authors have the answer to the automated cooking process; this patented technology is called Convection AutoLogic (CAL). The beauty of the technology is that it requires no extra hardware for the existing oven system. They use the existing temperature probe, whether it is an RTD, thermocouple, or thermistor. This means that the manufacturer does not have to be burdened with extra costs associated with automated cooking in comparison to standard ovens. The only change to the oven is the program in the central processing unit (CPU) on the board. As for its operation, when the user places the food into the oven, he or she is required to select a category (e.g., beef, poultry, or casseroles) and then simply press the start button. The CAL program then begins its cooking program. It first looks at the ambient oven temperature to see if it is a cold, warm, or hot start. CAL stores this data and then begins to look at the food`s thermal footprint. After CAL has properly detected this thermal footprint, it can calculate the time and temperature at which the food needs to be cooked. CAL then sets up these factors for the cooking stage of the program and, when the food has finished cooking, the oven is turned off automatically. The total time for this entire process is the same as the standard cooking time the user would normally set. The CAL program can also compensate for varying line voltages and detect when the oven door is opened. With all of these varying factors being monitored, CAL can produce a perfectly cooked item with minimal user input.

Boyer, M.A.; Eke, K.I. [Apollo U.S.A. Inc., Orlando, FL (United States)] [Apollo U.S.A. Inc., Orlando, FL (United States)

1998-03-01T23:59:59.000Z

296

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Showerheads Showerheads Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the water consumption level of showerheads since 1992. A showerhead is a perforated nozzle that distributes water over a large solid angle at point of use, generally overhead of the bather. They are used widely in residential and commercial settings. The current standard will save approximately 6 quads of energy and result in approximately $120 billion in energy bill savings for products shipped from 1994-2013. The standard will avoid about 329.2 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 64.5 million automobiles. The Standards and Test Procedures for this product are related to Rulemaking for Plumbing Products Test Procedure.

297

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Computer Room Air Conditioners Computer Room Air Conditioners Sign up for e-mail updates on regulations for this and other products The Department of Energy (DOE) has regulated the energy efficiency level of computer room air conditioners (CRACs) since 2012. A CRAC is a device that monitors and maintains the temperature, air distribution, and humidity in a network room or data center and is rated as a computer room air conditioner in accordance with 10 CFR 431.96. Recent Updates | Standards | Test Procedures | Waiver, Exception, and Exemption Information | Statutory Authority | Historical Information | Contact Information Recent Updates There are no recent updates for this product. Standards for Computer Room Air Conditioners The following content summarizes the energy conservation standards for CRACs. The text is not an official reproduction of the Code of Federal Regulations and should not be used for legal research or citation.

298

Integration of automation design information using XML technologies  

E-Print Network [OSTI]

Integration of automation design information using XML technologies Master of Science Thesis Mika UNIVERSITY OF TECHNOLOGY DEPARTMENT OF AUTOMATION #12;2 Abstract TAMPERE UNIVERSITY OF TECHNOLOGY Automation Degree Program Institute of Automation and Control Viinikkala, Mika: Integration of automation design

299

Mobile home automation: merging mobile value added services and home automation technologies  

Science Journals Connector (OSTI)

In this paper we study mobile home automation, a field that emerges from an integration of mobile application platforms and home automation technologies. We motivate our research and provide ... options of how he...

Goetz Botterweck; J. Felix Hampe…

2009-06-01T23:59:59.000Z

300

Appliances and Commercial Equipment Standards: Guidance  

Broader source: Energy.gov (indexed) [DOE]

Office Office HOME ABOUT ENERGY EFFICIENT TECHNOLOGIES RESIDENTIAL BUILDINGS COMMERCIAL BUILDINGS APPLIANCE & EQUIPMENT STANDARDS BUILDING ENERGY CODES EERE » Building Technologies Office » Appliances & Equipment Standards About Standards & Test Procedures Implementation, Certification & Enforcement Rulemakings & Notices Further Guidance ENERGY STAR® Guidance and Frequently Asked Questions This webpage is designed to provide guidance and answer Frequently Asked Questions (FAQs) on the U.S. Department of Energy's appliance standards program. Guidance types span all covered products and covered equipment and cover such topics as: definitions, scope of coverage, conservation standards, test procedures, certification, Compliance and Certification Management System (CCMS), and enforcement. This website offers users an

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Long Length Contaminated Equipment Maintenance Plan  

SciTech Connect (OSTI)

The purpose of this document is to provide the maintenance requirements of the Long Length Contaminated Equipment (LLCE) trailers and provide a basis for the maintenance frequencies selected. This document is applicable to the LLCE Receiver trailer and Transport trailer assembled by Mobilized Systems Inc. (MSI). Equipment used in conjunction with, or in support of, these trailers is not included. This document does not provide the maintenance requirements for checkout and startup of the equipment following the extended lay-up status which began in the mid 1990s. These requirements will be specified in other documentation.

ESVELT, C.A.

2000-02-01T23:59:59.000Z

302

Incidents of chemical reactions in cell equipment  

SciTech Connect (OSTI)

Strongly exothermic reactions can occur between equipment structural components and process gases under certain accident conditions in the diffusion enrichment cascades. This paper describes the conditions required for initiation of these reactions, and describes the range of such reactions experienced over nearly 50 years of equipment operation in the US uranium enrichment program. Factors are cited which can promote or limit the destructive extent of these reactions, and process operations are described which are designed to control the reactions to minimize equipment damage, downtime, and the possibility of material releases.

Baldwin, N.M.; Barlow, C.R. [Uranium Enrichment Organization, Oak Ridge, TN (United States)

1991-12-31T23:59:59.000Z

303

NAFTA opportunities: Electrical equipment and power generation  

SciTech Connect (OSTI)

The North American Free Trade Agreement (NAFTA) provides significant commercial opportunities in Mexico and Canada for the United States electric equipment and power generation industries, through increased goods and services exports to the Federal Electricity Commission (CFE) and through new U.S. investment in electricity generation facilities in Mexico. Canada and Mexico are the United States' two largest export markets for electrical equipment with exports of $1.53 billion and $1.51 billion, respectively, in 1992. Canadian and Mexican markets represent approximately 47 percent of total U.S. exports of electric equipment. The report presents an economic analysis of the section.

Not Available

1993-01-01T23:59:59.000Z

304

Beating the Heat! Automated Characterization of Piezoelectric Tubes for Starbugs  

E-Print Network [OSTI]

The Australian Astronomical Observatory has extensively prototyped a new robotic positioner to allow simultaneous positioning of optical fibers at the focal plane called 'Starbugs'. The Starbug devices each consist of two concentric piezoelectric tubes that 'walk' the optical fiber over the focal plane to accuracy of several microns. Ongoing research has led to the development of several Starbug prototypes, but lack of performance data has hampered further progress in the design of the Starbug positioners and the support equipment required to power and control them. Furthermore, Starbugs have been selected for the TAIPAN instrument, a prototype for MANIFEST on the GMT. A need now arises to measure and characterize 100's of piezoelectric tubes before full scale production of Starbugs for TAIPAN. The manual measurements of these piezoelectric tubes are a time consuming process taking several hours. Therefore, a versatile automated system is needed to measure and characterize these tubes in the laboratory before...

Piersiak, Rafal; Gilbert, James; Muller, Rolf

2014-01-01T23:59:59.000Z

305

Appliances and Commercial Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Central Air Conditioners and Heat Pumps Residential Central Air Conditioners and Heat Pumps Sign up for e-mail updates on regulations for this and other products Manufacturers have been required to comply with the Department of Energy's (DOE) energy conservation standards for residential central air conditioners and heat pumps since 1992. Residential central air conditioners and heat pumps are installed as part of a home's central heating and cooling system. They use ducts to distribute cooled or dehumidified air to more than one room. Residential central air conditioners and heat pumps include split system central air conditioners and heat pumps; single package central air conditioners, small-duct high-velocity products, and space constrained products. The standards mandatory in 1992 and 1993 will save approximately 2.9 quads of energy and result in approximately $29 billion in energy bill savings from 1993-2023. The standard will avoid about 160 million metric tons of carbon dioxide emissions, equivalent to the annual greenhouse gas emissions of about 31.4 million automobiles.

306

An Automated Raman Device for Gout Diagnosis  

Science Journals Connector (OSTI)

This study reports an automated Raman device to identify crystals in synovial aspirates from patients with gout symptoms. Combined with sample preparation, the device could diagnose...

Li, Bolan

307

Automated Logic Restructuring with aSPFDs  

Science Journals Connector (OSTI)

This chapter presents a comprehensive methodology to automate logic restructuring in combinational and sequential circuits. This technique algorithmically constructs the required transformation by utilizing a ...

Yu-Shen Yang; Subarna Sinha; Andreas Veneris…

2011-01-01T23:59:59.000Z

308

Automated Transportation Management System (ATMS) | Department...  

Office of Environmental Management (EM)

of Energy's (DOE's) Automated Transportation Management System is an integrated web-based logistics management system allowing users to manage inbound and outbound freight...

309

Recommendation 207 : Automate the Stewardship Verification Process...  

Office of Environmental Management (EM)

recommends exploring ways to automate the stewardship tracking process and establish a web-based solution for managing long-term stewardship information for the Oak Ridge...

310

Chapter 38, Design Automation for Microelectronics, Springer Handbook of Automation Deming Chen  

E-Print Network [OSTI]

Chapter 38, Design Automation for Microelectronics, Springer Handbook of Automation Deming Chen of hardware and software systems in the past several decades. CAD techniques are the key driving forces behind techniques. In this chapter we will introduce the fundamentals of design automation as an engineering field

Chen, Deming

311

Definition: Equipment Rating | Open Energy Information  

Open Energy Info (EERE)

Rating Rating Jump to: navigation, search Dictionary.png Equipment Rating The maximum and minimum voltage, current, frequency, real and reactive power flows on individual equipment under steady state, short-circuit and transient conditions, as permitted or assigned by the equipment owner.[1] Also Known As Standard current ratings Related Terms reactive power, smart grid References ↑ Glossary of Terms Used in Reliability Standards An i LikeLike UnlikeLike You like this.Sign Up to see what your friends like. nline Glossary Definition Retrieved from "http://en.openei.org/w/index.php?title=Definition:Equipment_Rating&oldid=502535" Categories: Definitions ISGAN Definitions What links here Related changes Special pages Printable version Permanent link Browse properties

312

Piedmont Natural Gas - Residential Equipment Efficiency Program |  

Broader source: Energy.gov (indexed) [DOE]

Piedmont Natural Gas - Residential Equipment Efficiency Program Piedmont Natural Gas - Residential Equipment Efficiency Program Piedmont Natural Gas - Residential Equipment Efficiency Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Heating Appliances & Electronics Water Heating Maximum Rebate 2 rebates per household Program Info State North Carolina Program Type Utility Rebate Program Rebate Amount High-Efficiency Furnace: $175 Tankless Water Heater: $150 Tank Water Heater: $50 Provider Gas Technology and Energy Services Piedmont Natural Gas offers rebates on high-efficiency natural gas tankless water heaters, tank water heaters and furnaces. Customers on the 101-Residential Service rate are eligible for these rebates. Rebates are only provided for qualifying natural gas equipment that is installed to

313

Laboratory Equipment Donation Program - Home Page  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

U.S. Department of Energy U.S. Department of Energy Laboratory Equipment Donation Program Home About LEDP FAQ Application Site Index Contact Us Administrative Login SEARCH: Go! view equipment list LEDP News Latest Equipment Added as of January 08, 2014: 1. DATA HANDLING SYSTEM 89514133530195 2. METER, VOLT 89514133530179 3. RECORDER, STRIP 89514133530184 4. RECORDER, STRIP 89514133530185 5. SCINTILLATOR STRIPS, 1.9 CM X 1.5 CM X 96 CM 89514133530188 Quick Links What type of equipment is available? Who is eligible to apply? How long will it take to find out if my application has been approved? Who is responsible for arranging and paying for shipping? RSS Get Widgets Bookmark and Share Get the tools you need to inspire innovation and creativity The United States Department of Energy (DOE), in accordance with its

314

HVAC Equipment Rebate Program | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

HVAC Equipment Rebate Program HVAC Equipment Rebate Program HVAC Equipment Rebate Program < Back Eligibility Agricultural Commercial Industrial Installer/Contractor Institutional Multi-Family Residential Nonprofit Schools Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Heat Pumps Maximum Rebate Rebates of greater than $5,000 require pre-approval Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Varies depending on technology and efficiency Provider Efficiency Vermont NOTE: Rebate reservations are required for all boiler and furnace projects. Efficiency Vermont offers rebates for commercial installations of high-efficiency HVAC equipment and controls. For businesses and purchases

315

Industrial Equipment Demand and Duty Factors  

E-Print Network [OSTI]

Demand and duty factors have been measured for selected equipment (air compressors, electric furnaces, injection molding machines, centrifugal loads, and others) in industrial plants. Demand factors for heavily loaded air compressors were near 100...

Dooley, E. S.; Heffington, W. M.

316

BCM 2 Equipment Inventory | Sample Preparation Laboratories  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

& Material Science Laboratory 2 Title Equipment Type Description Accumet Basic AB15 pH meter pH Meter pH meters with combination AgAgCl electrode and ATC probe. Corning 430 pH...

317

UNIVERSITY OF WASHINGTON ANNUAL EQUIPMENT TESTING AND  

E-Print Network [OSTI]

UNIVERSITY OF WASHINGTON ANNUAL EQUIPMENT TESTING AND MAINTENANCE SUMMARY DIVING SAFETY PROGRAM Date Tested Condition when received Intermediate Pressure Inhalation Resistance Exhalation Resistance Tested Make Serial Number Date Tested Results DEPTH GAUGE BUOYANCY COMPENSATOR Make Serial Number Date

Wilcock, William

318

Safety Topic: Rota/ng Equipment  

E-Print Network [OSTI]

Safety Topic: Rota/ng Equipment Jus/n Kleingartner #12;Safety protocols 2 #12;Safety protocols for opera/ng a lathe · Don'ts: ­ Do not wear gloves

Cohen, Robert E.

319

An Approach to Evaluating Equipment Efficiency Policies  

E-Print Network [OSTI]

AN APPROACH TO EVALUATING EQUIPMENT EFFICIENCY POLICIES Donald E. Newsom, Ph.D. and Allan R. Evans, Ph.D., P.E. Argonne National Laboratory, Argonne, Illinois ABSTRACT The National Energy Conservation Policy Act of 1978 authorized studies...

Newsom, D. E.; Evans, A. R.

1980-01-01T23:59:59.000Z

320

Cruising Equipment Company CECO | Open Energy Information  

Open Energy Info (EERE)

Cruising Equipment Company CECO Cruising Equipment Company CECO Jump to: navigation, search Name Cruising Equipment Company (CECO) Place Seattle, Washington Zip 98107 Product Maker of pollution control equipment - bought by Xantrex in 2000. Coordinates 47.60356°, -122.329439° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":47.60356,"lon":-122.329439,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Automating Logical Preservation for Small Institutions with Hoppla  

E-Print Network [OSTI]

Automating Logical Preservation for Small Institutions with Hoppla Stephan Strodl, Petar Petrov and outsources digital preservation expertise. This paper presents the automated logical preservation process of automating logical preservation by outsourcing expertise. 1 Introduction Digital information form essential

322

Computer optimization of earthmoving equipment arrays  

E-Print Network [OSTI]

higher degree of equipment specialization. Thus, the con- tractor attempts now to insure that individual segments of jobs are performed by the most economical means available to him. The choice of equipment to be used is difficult indeed... drawn carts. Next came use of the drag scraper followed by a wheel-mounted scraper which could dig, transport and dump its load. A major contribution to the earthmoving industry was the track-type tractor, which was developed in 1904. The potential...

Pate, Jep Earl

2012-06-07T23:59:59.000Z

323

List of Agricultural Equipment Incentives | Open Energy Information  

Open Energy Info (EERE)

Agricultural Equipment Incentives Agricultural Equipment Incentives Jump to: navigation, search The following contains the list of 90 Agricultural Equipment Incentives. CSV (rows 1 - 90) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active Agricultural Energy Efficiency Program (New York) State Rebate Program New York Agricultural Agricultural Equipment Boilers Chillers Custom/Others pending approval Dishwasher Furnaces Heat pumps Heat recovery Lighting Lighting Controls/Sensors Motor VFDs Motors Water Heaters Commercial Cooking Equipment Commercial Refrigeration Equipment Food Service Equipment Yes Agricultural Lighting and Equipment Rebate Program (Vermont) State Rebate Program Vermont Agricultural Agricultural Equipment Custom/Others pending approval Lighting

324

CRAD, Nuclear Facility Construction - Mechanical Equipment - June 26, 2012  

Broader source: Energy.gov (indexed) [DOE]

Nuclear Facility Construction - Mechanical Equipment - June Nuclear Facility Construction - Mechanical Equipment - June 26, 2012 CRAD, Nuclear Facility Construction - Mechanical Equipment - June 26, 2012 June 26, 2012 Nuclear Facility Construction - Mechanical Equipment Installation, (HSS CRAD 45-53, Rev. 0) The purpose of this criteria review and approach, this CRAD includes mechanical equipment installation, including connections of the equipment to installed piping systems, and attachments of the equipment to structures (concrete, structural steel, or embed plates). Mechanical equipment includes items such as pumps and motors, valves, tanks, glove boxes, heat exchangers, ion exchangers, service air system, fire pumps and tanks, and heating, ventilation, and air condition (HVAC) equipment such as fans, scrubbers and filters.

325

Alternative Fuels Data Center: Pollution Control Equipment Exemption  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Pollution Control Pollution Control Equipment Exemption to someone by E-mail Share Alternative Fuels Data Center: Pollution Control Equipment Exemption on Facebook Tweet about Alternative Fuels Data Center: Pollution Control Equipment Exemption on Twitter Bookmark Alternative Fuels Data Center: Pollution Control Equipment Exemption on Google Bookmark Alternative Fuels Data Center: Pollution Control Equipment Exemption on Delicious Rank Alternative Fuels Data Center: Pollution Control Equipment Exemption on Digg Find More places to share Alternative Fuels Data Center: Pollution Control Equipment Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Pollution Control Equipment Exemption Dedicated original equipment manufacturer natural gas vehicles and

326

Automated Critical Peak Pricing Field Tests: 2006 Pilot Program Description and Results  

E-Print Network [OSTI]

Target Hayward Software client Automated Logic TargetAntioch Automated Logic Target Bakersfield Software client

Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila

2007-01-01T23:59:59.000Z

327

Open Automated Demand Response Communications Specification (Version 1.0)  

E-Print Network [OSTI]

and Techniques for Demand Response. May 2007. LBNL-59975.to facilitate automating  demand response actions at the Interoperable Automated Demand Response Infrastructure,

Piette, Mary Ann

2009-01-01T23:59:59.000Z

328

Open Automated Demand Response Dynamic Pricing Technologies and Demonstration  

E-Print Network [OSTI]

Goodin. 2009. “Open Automated Demand Response Communicationsin Demand Response for Wholesale Ancillary Services. ” InOpen Automated Demand Response Demonstration Project. LBNL-

Ghatikar, Girish

2010-01-01T23:59:59.000Z

329

Home Automation : Smart home technology and template house design.  

E-Print Network [OSTI]

??In this thesis, home automation’s general knowledge, technology information and each component will be introduced to the reader in the first half of the whole… (more)

Zheng, Zeya

2013-01-01T23:59:59.000Z

330

V-205: IBM Tivoli System Automation for Multiplatforms Java Multiple...  

Broader source: Energy.gov (indexed) [DOE]

5: IBM Tivoli System Automation for Multiplatforms Java Multiple Vulnerabilities V-205: IBM Tivoli System Automation for Multiplatforms Java Multiple Vulnerabilities July 29, 2013...

331

U-047: Siemens Automation License Manager Bugs Let Remote Users...  

Broader source: Energy.gov (indexed) [DOE]

7: Siemens Automation License Manager Bugs Let Remote Users Deny Service or Execute Arbitrary Code U-047: Siemens Automation License Manager Bugs Let Remote Users Deny Service or...

332

Appropriate automation of rail signalling systems: a human factors study.  

E-Print Network [OSTI]

??This thesis examines the effect of automation in the rail signalling environment. The level of automation in a system can be described as ranging along… (more)

Balfe, Nora

2010-01-01T23:59:59.000Z

333

Automation of amperometric titrations with rotating platinum electrodes  

Science Journals Connector (OSTI)

Automation of amperometric titrations with rotating platinum electrodes ... A modification of an earlier described apparatus allows for the automation of amperometric titrations with rotating platinum electrodes. ...

Eugene D. Olsen; Roger D. Walton

1966-01-01T23:59:59.000Z

334

V-132: IBM Tivoli System Automation Application Manager Multiple...  

Energy Savers [EERE]

32: IBM Tivoli System Automation Application Manager Multiple Vulnerabilities V-132: IBM Tivoli System Automation Application Manager Multiple Vulnerabilities April 12, 2013 -...

335

ISA Approves Standard for Wireless Automation in Process Control...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

ISA Approves Standard for Wireless Automation in Process Control Applications ISA Approves Standard for Wireless Automation in Process Control Applications On September 9, the...

336

Small- and Medium-Size Building Automation and Control System...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Emerging...

337

Universal software packages to model the distributed-parameter systems  

Science Journals Connector (OSTI)

Consideration was given to the universal software packages for modeling objects and distributed-parameter systems obeying the partial differential equations. The packages may serve as important tools for industrial automation because the majority of ... Keywords: 07.05.Tp

E. E. Dudnikov

2009-01-01T23:59:59.000Z

338

Electricity Used by Office Equipment and Network Equipment in the U.S.: Detailed Report and Appendices  

E-Print Network [OSTI]

LBNL-45917 Electricity Used by Office Equipment and Network Equipment in the U.S.: Detailed Report..............................................................................................46 #12;#12;1 Electricity Used by Office Equipment and Network Equipment in the U.S. Kaoru Kawamoto and network equipment, there has been no recent study that estimates in detail how much electricity

339

Designing shipboard electrical distribution systems for optimal reliability.  

E-Print Network [OSTI]

??Analysis was performed to quantify and compare the reliability of several different notional shipboard DC distribution system topologies in serving their equipment loads. Further, the… (more)

Stevens, McKay Benjamin

2013-01-01T23:59:59.000Z

340

Demand Response and Open Automated Demand Response  

E-Print Network [OSTI]

LBNL-3047E Demand Response and Open Automated Demand Response Opportunities for Data Centers G described in this report was coordinated by the Demand Response Research Center and funded by the California. Demand Response and Open Automated Demand Response Opportunities for Data Centers. California Energy

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

PeopleSoft HR ECR Automation Process  

E-Print Network [OSTI]

PeopleSoft HR ECR Automation Process Short Term Disability with Pay May 2011 #12;Processing a Short Term Disability with Pay ECR Search Page To process a Short Term Disability using the automated ECR process, follow the menu navigation below: Home > Employee Change Request (ECR) > Use > ECR Create

Huang, Jianyu

342

PeopleSoft HR ECR Automation Process  

E-Print Network [OSTI]

PeopleSoft HR ECR Automation Process Revise Existing SWB May 2011 #12;Processing a Short Work Break Date Revision ECR Search Page To process a Short Work Break Date revision using the automated ECR process, follow the menu navigation below: Home > Employee Change Request (ECR) > Use > ECR Create

Huang, Jianyu

343

PeopleSoft HR ECR Automation Process  

E-Print Network [OSTI]

PeopleSoft HR ECR Automation Process Employee Work Hours Change (Temporary Basis) May 2012 #12 Documentation May, 2012 When the Originator is ready to create an Hours Change Request using the automated ECR the instructions below: - Home > Employee Change Request (ECR) > Use > ECR Create · If you know the Name or Eagle

Huang, Jianyu

344

PeopleSoft HR ECR Automation Process  

E-Print Network [OSTI]

PeopleSoft HR ECR Automation Process Long Term Disability May 2011 #12;Processing a Long Term Disability LTD ECR Search Page To process an LTD transaction using the automated ECR process, follow the menu navigation below: Home > Employee Change Request (ECR) > Use > ECR Create 2 · If you know the Name or Eagle

Huang, Jianyu

345

PeopleSoft HR ECR Automation Process  

E-Print Network [OSTI]

PeopleSoft HR ECR Automation Process Leave of Absence May 2012 #12;2 Table of Contents Create the Originator is ready to create a Leave of Absence using the automated ECR process, he/she will follow the menu navigation below to access the employee search page and then use the instructions below: - Home > Employee

Huang, Jianyu

346

Technical University of Denmark rsted DTU Automation  

E-Print Network [OSTI]

Technical University of Denmark �rsted · DTU Automation Project: SICAM - SIngle Conversion stage;Isolated PDM and PWM DC-AC SICAMs Petar Ljusev, MSc., Ph.D. student, �rsted · DTU Automation e-mail: pl

347

D Riso-R-429 Automated Uranium  

E-Print Network [OSTI]

routinely used analytical techniques for uranium determina- tions in geological samples, fissionCM i D Riso-R-429 Automated Uranium Analysis by Delayed-Neutron Counting H. Kunzendorf, L. Løvborg AUTOMATED URANIUM ANALYSIS BY DELAYED-NEUTRON COUNTING H. Kunzendorf, L. Løvborg and E.M. Christiansen

348

The role of the digital fault recorder in the automated substation  

SciTech Connect (OSTI)

This paper addresses the role of the digital fault recorder in the automated substation. The topics of the paper include distributed architecture, the substation LAN and reduced installation costs, multiple functions, improved substation intelligence, record generation and record merging, fault summaries, master station software, and future considerations.

Brandt, J.D. [Hathaway Corp., Littleton, CO (United States)

1996-10-01T23:59:59.000Z

349

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2  

E-Print Network [OSTI]

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2 3 4 Peng Xu, Philip Haves HVAC system (air handling units and air distribution systems). The models are used to predict of automatic documentation methods in the library. INTRODUCTION The increasing complexity of building HVAC

350

1982 analyses and reports: equipment availability report; component cause code report; and equipment availability report  

SciTech Connect (OSTI)

This equipment availability report (1973 to 1982, 1982) presents statistical information on the performance of the major types of generating units and their major component groups. (DLC)

Not Available

1982-01-01T23:59:59.000Z

351

Optimization of automation: I. Estimation method of cognitive automation rates reflecting the effects of automation on human operators in nuclear power plants  

Science Journals Connector (OSTI)

Abstract Since automation was introduced in various industrial fields, the concept of the automation rate has been used to indicate the inclusion proportion of automation among all work processes or facilities. Expressions of the inclusion proportion of automation are predictable, as is the ability to express the degree of the enhancement of human performance. However, many researchers have found that a high automation rate does not guarantee high performance. Therefore, to reflect the effects of automation on human performance, this paper proposes a new estimation method of the automation rate that considers the effects of automation on human operators in nuclear power plants (NPPs). Automation in \\{NPPs\\} can be divided into two types: system automation and cognitive automation. Some general descriptions and characteristics of each type of automation are provided, and the advantages of automation are investigated. The advantages of each type of automation are used as measures of the estimation method of the automation rate. One advantage was found to be a reduction in the number of tasks, and another was a reduction in human cognitive task loads. The system and the cognitive automation rate were proposed as quantitative measures by taking advantage of the aforementioned benefits. To quantify the required human cognitive task loads and thus suggest the cognitive automation rate, Conant’s information-theory-based model was applied. The validity of the suggested method, especially as regards the cognitive automation rate, was proven by conducting experiments. The result showed that a decreased rate of the operator working time was significantly related to the cognitive automation rate and that the calculation of the cognitive task load was useful as a measure of the cognitive automation rate.

Seung Min Lee; Jong Hyun Kim; Poong Hyun Seong

2014-01-01T23:59:59.000Z

352

Automation of hydroelectric power plants  

SciTech Connect (OSTI)

This paper describes how the author's company has been automating its hydroelectric generating plants. The early automations were achieved with a relay-type supervisory control system, relay logic, dc tachometer, and a pneumatic gate-position controller. While this system allowed the units to be started and stopped from a remote location, they were operated at an output that was preset by the pneumatic control at the generating site. The supervisory control system at the site provided such information as unit status, generator breaker status, and a binary coded decimal (BCD) value of the pond level. The generating units are started by energizing an on-site relay that sets the pneumatic gate controller to a preset value above the synchronous speed of the hydroelectric generator. The pneumatic controller then opens the water-wheel wicket gates to the preset startup position. As the hydroelectric generator starts to turn, the machine-mounted dc tachometer produces a voltage. At a dc voltage equivalent to synchronous speed, the generator main breaker closes, and a contact from the main breaker starts a field-delay timer. Within a few seconds, the field breaker closes. Once the cycle is complete, a relay changes the pneumatic setpoint to a preset operating point of about 8/10 wicket gate opening.

Grasser, H.S. (Consolidated Papers, Inc., Wisconsin Rapids, WI (US))

1990-03-01T23:59:59.000Z

353

Automation of Network-Based Scientific Workflows  

SciTech Connect (OSTI)

Comprehensive, end-to-end, data and workflow management solutions are needed to handle the increasing complexity of processes and data volumes associated with modern distributed scientific problem solving, such as ultra-scale simulations and high-throughput experiments. The key to the solution is an integrated network-based framework that is functional, dependable, fault-tolerant, and supports data and process provenance. Such a framework needs to make development and use of application workflows dramatically easier so that scientists' efforts can shift away from data management and utility software development to scientific research and discovery An integrated view of these activities is provided by the notion of scientific workflows - a series of structured activities and computations that arise in scientific problem-solving. An information technology framework that supports scientific workflows is the Ptolemy II based environment called Kepler. This paper discusses the issues associated with practical automation of scientific processes and workflows and illustrates this with workflows developed using the Kepler framework and tools.

Altintas, I. [University of California, La Jolla; Barreto, R. [Oak Ridge National Laboratory (ORNL); Blondin, J. M. [North Carolina State University; Cheng, Z. [North Carolina State University; Critchlow, T. [Lawrence Livermore National Laboratory (LLNL); Khan, A. [University of Utah; Klasky, Scott A [ORNL; Ligon, J. [North Carolina State University; Ludaescher, B. [University of California, Davis; Mouallem, P. A. [North Carolina State University; Parker, S. [University of Utah; Podhorszki, Norbert [University of California, Davis; Shoshani, A. [Lawrence Berkeley National Laboratory (LBNL); Silva, C. [University of Utah; Vouk, M. A. [North Carolina State University

2007-01-01T23:59:59.000Z

354

Substation automation -- a ``bottoms up`` approach  

SciTech Connect (OSTI)

The proliferation of multi-purpose intelligent electronic devices in substations brought the availability of abundant and often overlapping data at the substation. This data can be used for improving the operation and maintenance of the substations and the entire power system. The objective of substation automation is to use technology to gather, consolidate and utilize this data for increasing the efficiency of power system operation and maintenance. Often automation functions are developed and offered around the capabilities of the preferred hardware and software of the integrator. Emphasis is placed on hardware, software and communication protocols rather than need, methodology and application. This can result in over-automation with complex, expensive and ineffective systems, or under-automation that fails to achieve the user`s objectives. The objective is to select appropriate hardware, software and methodology to build the most cost effective system to get the desired results. This paper describes steps to ensure the successful implementation of substation automation.

Thomas, J. [General Electric, Malvern, PA (United States)

1996-10-01T23:59:59.000Z

355

Dynamic Whitelist Generation for Automated Response  

Broader source: Energy.gov (indexed) [DOE]

Methodology Methodology Results Dynamic Whitelist Generation for Automated Response Chris Strasburg, Josh Adams Ames Laboratory, US DOE cstras@ameslab.gov, jadams@ameslab.gov The Ames Laboratory, US DOE 1 Dynamic Whitelist Generation for Automated Response Introduction Methodology Results Outline 1 Introduction About Ames Laboratory Motivation 2 Methodology Data Classifiers Experiments 3 Results The Ames Laboratory, US DOE 2 Dynamic Whitelist Generation for Automated Response Introduction Methodology Results About Ames Laboratory Motivation Ames Physical Environment The Ames Laboratory, US DOE 3 Dynamic Whitelist Generation for Automated Response Introduction Methodology Results About Ames Laboratory Motivation Ames Network Environment The Ames Laboratory, US DOE 4 Dynamic Whitelist Generation for Automated Response Introduction Methodology Results About Ames

356

Impacts of Water Quality on Residential Water Heating Equipment  

SciTech Connect (OSTI)

Water heating is a ubiquitous energy use in all residential housing, accounting for 17.7% of residential energy use (EIA 2012). Today, there are many efficient water heating options available for every fuel type, from electric and gas to more unconventional fuel types like propane, solar, and fuel oil. Which water heating option is the best choice for a given household will depend on a number of factors, including average daily hot water use (total gallons per day), hot water draw patterns (close together or spread out), the hot water distribution system (compact or distributed), installation constraints (such as space, electrical service, or venting accommodations) and fuel-type availability and cost. While in general more efficient water heaters are more expensive than conventional water heating technologies, the savings in energy use and, thus, utility bills can recoup the additional upfront investment and make an efficient water heater a good investment over time in most situations, although the specific payback period for a given installation will vary widely. However, the expected lifetime of a water heater in a given installation can dramatically influence the cost effectiveness and savings potential of a water heater and should be considered, along with water use characteristics, fuel availability and cost, and specific home characteristics when selecting the optimum water heating equipment for a particular installation. This report provides recommendations for selecting and maintaining water heating equipment based on local water quality characteristics.

Widder, Sarah H.; Baechler, Michael C.

2013-11-01T23:59:59.000Z

357

Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Ethanol Production Ethanol Production Equipment Tax Exemption to someone by E-mail Share Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Facebook Tweet about Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Twitter Bookmark Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Google Bookmark Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Delicious Rank Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on Digg Find More places to share Alternative Fuels Data Center: Ethanol Production Equipment Tax Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Ethanol Production Equipment Tax Exemption

358

Novel Energy Conversion Equipment for Low Temperature Geothermal...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Novel Energy Conversion Equipment for Low Temperature Geothermal Resources Novel Energy Conversion Equipment for Low Temperature Geothermal Resources Project objective: Develop...

359

Microsoft Word - CX_McNaryEquipmentAcquisition.doc  

Broader source: Energy.gov (indexed) [DOE]

to purchase equipment owned by Umatilla Electric Cooperative (UEC) within BPA's McNary Substation. BPA already maintains all of UEC's equipment in the substation under an...

360

Dispensing Equipment Testing With Mid-Level Ethanol/Gasoline...  

Energy Savers [EERE]

Dispensing Equipment Testing With Mid-Level EthanolGasoline Test Fluid Dispensing Equipment Testing With Mid-Level EthanolGasoline Test Fluid The National Renewable Energy...

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Direct Liquid Cooling for Electronic Equipment  

E-Print Network [OSTI]

by  the  power  distribution  and  cooling  systems.  The  the  power   distribution  and  cooling  infrastructure  IT  power  consumed  along  with   the  cooling  required  

Coles, Henry

2014-01-01T23:59:59.000Z

362

NSLS Services | Repair & Equipment Services  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Repair & Equipment Services Repair & Equipment Services Cleaning Facility (BNL Central Shops) Solvent cleaning of vacuum parts and leak checking service is also available. Work is billed to each user via a BNL ILR. Contact the NSLS Building Manager to arrange for any of these services. Electronics Repair Limited repairs for electronic equipment are available from an outside contractor through the Control Room. Contact Control Room Supervisor Randy Church (x2550 or x2736, pager 5310). Shipping memos are filled out on the web, and pick ups are on Fridays. Come to the Control Room for assistance. The user should call the contractor on the day before scheduled pickups to alert the contractor of the pickup. Items to be repaired should be left in the Control Room with the completed shipping memo. Costs are charged to the

363

AUTOMATING GROUNDWATER SAMPLING AT HANFORD  

SciTech Connect (OSTI)

Until this past October, Fluor Hanford managed Hanford's integrated groundwater program for the U.S. Department of Energy (DOE). With the new contract awards at the Site, however, the CH2M HILL Plateau Remediation Company (CHPRC) has assumed responsibility for the groundwater-monitoring programs at the 586-square-mile reservation in southeastern Washington State. These programs are regulated by the Resource Conservation and Recovery Act (RCRA) and the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). The purpose of monitoring is to track existing groundwater contamination from past practices, as well as other potential contamination that might originate from RCRA treatment, storage, and disposal (TSD) facilities. An integral part of the groundwater-monitoring program involves taking samples of the groundwater and measuring the water levels in wells scattered across the site. More than 1,200 wells are sampled each year. Historically, field personnel or 'samplers' have been issued pre-printed forms that have information about the well(s) for a particular sampling evolution. This information is taken from the Hanford Well Information System (HWIS) and the Hanford Environmental Information System (HEIS)--official electronic databases. The samplers used these hardcopy forms to document the groundwater samples and well water-levels. After recording the entries in the field, the samplers turned the forms in at the end of the day and the collected information was posted onto a spreadsheet that was then printed and included in a log book. The log book was then used to make manual entries of the new information into the software application(s) for the HEIS and HWIS databases. This is a pilot project for automating this tedious process by providing an electronic tool for automating water-level measurements and groundwater field-sampling activities. The automation will eliminate the manual forms and associated data entry, improve the accuracy of the information recorded, and enhance the efficiency and sampling capacity of field personnel. The goal of the effort is to eliminate 100 percent of the manual input to the database(s) and replace the management of paperwork by the field and clerical personnel with an almost entirely electronic process. These activities will include the following: scheduling the activities of the field teams, electronically recording water-level measurements, electronically logging and filing Groundwater Sampling Reports (GSR), and transferring field forms into the site-wide Integrated Document Management System (IDMS).

CONNELL CW; HILDEBRAND RD; CONLEY SF; CUNNINGHAM DE

2009-01-16T23:59:59.000Z

364

dieSel/heAvy equipMent College of Rural and Community Development  

E-Print Network [OSTI]

and equipment overhauls. Students work on large truck fuel, electrical and air systems, diesel engines 907-455-2809 www.ctc.uaf.edu/programs/diesel/ certificate Minimum Requirements for Certificate: 36 credits The diesel and heavy equipment mechanics program offers the student training in the maintenance

Hartman, Chris

365

After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-Load Equipment  

E-Print Network [OSTI]

LBNL-53729 After-hours Power Status of Office Equipment and Inventory of Miscellaneous Plug-Load To download this paper and related data go to: http://enduse.lbl.gov/Projects/OffEqpt.html The work described.................................................................................................................................................5 Office Equipment Data Collection

366

Conceptual design report, CEBAF basic experimental equipment  

SciTech Connect (OSTI)

The Continuous Electron Beam Accelerator Facility (CEBAF) will be dedicated to basic research in Nuclear Physics using electrons and photons as projectiles. The accelerator configuration allows three nearly continuous beams to be delivered simultaneously in three experimental halls, which will be equipped with complementary sets of instruments: Hall A--two high resolution magnetic spectrometers; Hall B--a large acceptance magnetic spectrometer; Hall C--a high-momentum, moderate resolution, magnetic spectrometer and a variety of more dedicated instruments. This report contains a short description of the initial complement of experimental equipment to be installed in each of the three halls.

NONE

1990-04-13T23:59:59.000Z

367

Automated cleaning of electronic components  

SciTech Connect (OSTI)

Environmental and operator safety concerns are leading to the elimination of trichloroethylene and chlorofluorocarbon solvents in cleaning processes that remove rosin flux, organic and inorganic contamination, and particulates from electronic components. Present processes depend heavily on these solvents for manual spray cleaning of small components and subassemblies. Use of alternative solvent systems can lead to longer processing times and reduced quality. Automated spray cleaning can improve the quality of the cleaning process, thus enabling the productive use of environmentally conscious materials, while minimizing personnel exposure to hazardous materials. We describe the development of a prototype robotic system for cleaning electronic components in a spray cleaning workcell. An important feature of the prototype system is the capability to generate the robot paths and motions automatically from the CAD models of the part to be cleaned, and to embed cleaning process knowledge into the automatically programmed operations.

Drotning, W.; Meirans, L.; Wapman, W.; Hwang, Y.; Koenig, L.; Petterson, B.

1994-07-01T23:59:59.000Z

368

A SIP-based Home Automation Platform: an Experimental Study  

E-Print Network [OSTI]

A SIP-based Home Automation Platform: an Experimental Study Benjamin Bertran, Charles Consel INRIA the requirements of home automation; we present the resulting architecture of a home automation system; and, we to tackle the challenges of the home automation domain. In this paper we present an approach and a platform

Boyer, Edmond

369

Fueling Robot Automates Hydrogen Hose Reliability Testing (Fact Sheet)  

SciTech Connect (OSTI)

Automated robot mimics fueling action to test hydrogen hoses for durability in real-world conditions.

Harrison, K.

2014-01-01T23:59:59.000Z

370

Automated Data Quality Analysis Research and Development  

E-Print Network [OSTI]

DOCUMENTATION 4.0 FUTURE DIRECTIONS 5.0 SUMMARY 6.0 CODE 1 2 3 5 5 12 17 17 18 February 2002, Final Report Energy Systems Laboratory, Texas A&M University p. 5 1.0 INTRODUCTION The Automated Data Quality process development is an effort to automate the analysis.... Automation of the "lower-level" data quality checking will enabled a more refined review process. Figure 1. Energy Core Polling and Reloading Process Diagram February 2002, Final Report Energy Systems Laboratory, Texas A&M University p. 6 2.2 Definitions...

Sweeney, J., Jr.; Haberl, J. S.

2002-01-01T23:59:59.000Z

371

j5 DNA Assembly Design Automation Software  

Science Journals Connector (OSTI)

j5 DNA Assembly Design Automation Software ... Here, we report the development and deployment of a web-based software tool, j5, which automates the design of scar-less multipart DNA assembly protocols including SLIC, Gibson, CPEC, and Golden Gate. ... The key innovations of the j5 design process include cost optimization, leveraging DNA synthesis when cost-effective to do so, the enforcement of design specification rules, hierarchical assembly strategies to mitigate likely assembly errors, and the instruction of manual or automated construction of scar-less combinatorial DNA libraries. ...

Nathan J. Hillson; Rafael D. Rosengarten; Jay D. Keasling

2011-12-07T23:59:59.000Z

372

Modular design for increasing assembly automation  

Science Journals Connector (OSTI)

Abstract Modular design can address the need for a high number of product variants and further allow a higher degree of automation in the assembly line. A framework is developed for the simultaneous modular product design and the design of automated manufacturing system. Product designs are optimized for automation using Design Structure Matrix and Modular Function Deployment. Alternative production systems are designed and accessed based on the analysis of assembly steps hierarchically. The implementation of the framework on the design of a production system for furniture assembly, able to handle multiple variants with a large number of components, is demonstrated.

Konstantinos Salonitis

2014-01-01T23:59:59.000Z

373

AUTOMATION IN THE MEAT INDUSTRY | Slaughter Line Operation  

Science Journals Connector (OSTI)

Abstract The strongest incentives for the slaughter industry to adopt automation technology relate to the drive for improved productivity through reduced labor. Automation in the pig slaughter industry has mainly been adopted in regions with high labor costs such as Northern Europe. In New Zealand, the lamb slaughter industry has been progressive in developing and using automation to automate the slaughter process. Automation in beef slaughter is limited because of the complexity associated with handling of the biological variation. Barriers for slaughter line automation include the high cost and complexity associated with the development of slaughter automation technology, combined with limited market size.

J.U. Nielsen; N.T. Madsen; R. Clarke

2014-01-01T23:59:59.000Z

374

Declarative Automated Cloud Resource Orchestration  

E-Print Network [OSTI]

orchestration · Cloud resource orchestration constraint optimization problems 4 Provider operational] · Orchestration procedures Transactions · Either commit or abort Distributed communication and optimization

Plotkin, Joshua B.

375

Asset Management Equipment Disposal Form -Refrigerant Recovery  

E-Print Network [OSTI]

enters the waste stream with the charge intact (e.g., motor vehicle air conditioners, refrigeratorsAsset Management Equipment Disposal Form - Refrigerant Recovery Safe Disposal Requirements Under refrigeration, cold storage warehouse refrigeration, chillers, and industrial process refrigeration) has to have

Sin, Peter

376

WAMPANOAG WELLNESS EQUIPMENT LENDING BANK POLICIES & PROCEDURES  

E-Print Network [OSTI]

vacuums and steam cleaners, can be used to address immediate concerns, such as intense cleaning to remove to enable the Health Service to measure the environmental impact of the use of the equipment in the homes moisture levels or improve air quality. STEP TWO: RECOMMENDATIONS As noted, recommendations in the Home

377

Research equipment: Surface Acoustic Wave (SAW) devices  

E-Print Network [OSTI]

of the acoustic wave. More specifically, the equipment consists of: i. HP 4195A (10Hz-500MHz) ii. HP 8753ES (30kHz measurements on many SAW devices iii. Agilent E5061A (300kHz-1.5GHz) http Scientific Corp.): Atmospheric plasma etching, for surface cleaning, surface treatment and activation

Gizeli, Electra

378

Research equipment: Surface Acoustic Wave (SAW) devices  

E-Print Network [OSTI]

, the equipment consists of: i. HP 4195A (10Hz-500MHz) ii. HP 8753ES (30kHz-3GHz) with time-gating option. Agilent E5061A (300kHz-1.5GHz) Switch control Network Analyzer Quartz Crystal Microbalance-coating of various polymeric films. Expanded Plasma Cleaner & PlasmaFloTM (Harrick Scientific Corp.): Atmospheric

Gizeli, Electra

379

Processing Equipment 2" Davis-Standard Extruder  

E-Print Network [OSTI]

Processing Equipment 2" Davis-Standard Extruder Improved Melting Grooved Feeding Capabilities Multiple Pressure Ports Along the Barrel Screw Cooling Kit Rod Die With Valved Adapter Higher Throughputs L Ring 1'' General Purpose Screw 3 Air-Cooled Barrel Zones Gala Industries Underwater Micropelletizer

Bone, Gary

380

Standardized equipment labeling program for electrical utilities  

SciTech Connect (OSTI)

The purpose of this supporting document is to provide specific guidelines required for Electrical Utilities to implement and maintain a standard equipment and piping labeling program in accordance with WHC-SP-0708, Chapter 18, {open_quotes}Westinghouse Hanford Company Conduct of Operations Manual{close_quotes}. Specific guidelines include definition of program responsibilities.

Not Available

1994-07-19T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Original article Enzymatic equipment of Ascosphaera apis  

E-Print Network [OSTI]

Original article Enzymatic equipment of Ascosphaera apis and the development of infection — The process of infection of honey bee brood by the fungus Ascosphaera apis was ini- tiated the fungus pierces the cuticle. Ascosphaera apis / Apis mellifera / larval cuticle / penetration / infection

Paris-Sud XI, Université de

382

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY  

E-Print Network [OSTI]

PROJECT REPORT HVAC EQUIPMENT DEMOGRAPHICS AND CAPACITY ANALYSIS TOOLS APPLICABLE TO MULTI Commercial HVAC Design Process 12 5.0 Conclusion 18 6.0 References 19 TABLE OF CONTENTS SECTIONS #12;MULTI performance by collectively improving the enve- lope, lighting and HVAC systems. The primary goals of the UC

California at Davis, University of

383

Standard hydrogen monitoring system equipment installation instructions  

SciTech Connect (OSTI)

This document provides the technical specifications for the equipment fabrication, installation, and sitework construction for the Standard Hydrogen Monitoring System. The Standard Hydrogen Monitoring System is designed to remove gases from waste tank vapor space and exhaust headers for continual monitoring and remote sample analysis.

Schneider, T.C.

1996-09-27T23:59:59.000Z

384

Unidata Community Equipment Awards Cover Sheet Proposal Title  

E-Print Network [OSTI]

RAID array with 4 TB storage · Support equipment including a rack, rack console, uninterruptable power

385

STATE OF CALIFORNIA VERIFICATION OF HIGH EER EQUIPMENT  

E-Print Network [OSTI]

STATE OF CALIFORNIA VERIFICATION OF HIGH EER EQUIPMENT CEC-CF-4R-MECH-23 (Revised 08/09) CALIFORNIA of High EER Equipment (Page 1 of 2) Site Address: Enforcement Agency: Permit Number: Registration Number 2009 Verification of High EER Equipment Procedures for verification of High EER Equipment are described

386

STATE OF CALIFORNIA VERIFICATION OF HIGH EER EQUIPMENT  

E-Print Network [OSTI]

STATE OF CALIFORNIA VERIFICATION OF HIGH EER EQUIPMENT CEC-CF-6R-MECH-23-HERS (Revised 08/09) CALIFORNIA ENERGY COMMISSION INSTALLATION CERTIFICATE CF-6R-MECH-23-HERS Verification of High EER Equipment 2009 Verification of High EER Equipment Procedures for verification of High EER Equipment are described

387

New designs in reconstructing the mechanical equipment of hydroelectric stations  

Science Journals Connector (OSTI)

1. Reliable operation of mechanical equipment can be assured, provided timely conduction of repairs and reconstr...

S. V. Leeson

1996-03-01T23:59:59.000Z

388

Page 1 of 3 Policy: Fire Protection Equipment Policy  

E-Print Network [OSTI]

Page 1 of 3 Policy: Fire Protection Equipment Policy Responsible Party: Director, Safety and Risk The Office of Safety and Risk Management (SRM) has developed, and implemented the Fire Protection Equipment of Fire Protection Equipment throughout MSU to maintain its working order. Fire Protection Equipment

Dyer, Bill

389

Electrical Equipment Replacement: Energy Efficiency versus System Compatibility  

E-Print Network [OSTI]

upgrading electrical equipment to energy efficient models, including conductor sizing, overcurrent protective devices, grounding, and harmonics. The pages that follow provide guidance in the decision-making process when replacing electrical equipment... equipment. Several areas of compatibility must be addressed for equipment to work properly. Critical areas of concern are conductor sizing, overcurrent protection devices, grounding, and harmonics. Conductor Sizing Conductors are sized...

Massey, G. W.

2005-01-01T23:59:59.000Z

390

Building Technologies Office: About the Appliance and Equipment Standards  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

About the Appliance and About the Appliance and Equipment Standards Program to someone by E-mail Share Building Technologies Office: About the Appliance and Equipment Standards Program on Facebook Tweet about Building Technologies Office: About the Appliance and Equipment Standards Program on Twitter Bookmark Building Technologies Office: About the Appliance and Equipment Standards Program on Google Bookmark Building Technologies Office: About the Appliance and Equipment Standards Program on Delicious Rank Building Technologies Office: About the Appliance and Equipment Standards Program on Digg Find More places to share Building Technologies Office: About the Appliance and Equipment Standards Program on AddThis.com... About History & Impacts Statutory Authorities & Rules Regulatory Processes

391

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Regulation Exemption to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Regulation Exemption on AddThis.com...

392

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Requirements to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on AddThis.com... More in this section... Federal State Advanced Search

393

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Installation Requirements to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Installation Requirements on AddThis.com...

394

Training program requirements for remote equipment operators in nuclear facilities  

SciTech Connect (OSTI)

One of the most neglected areas in the engineering development of remotely operated equipment applications in nuclear environments is the planning of adequate training programs for the equipment operators. Remote equipment accidents cannot be prevented solely by engineered safety features on the equipment. As a result of the experiences in using remote equipment in the recovery effort at Three Mile Island Unit 2 (TMI-2), guidelines for the development of remote equipment operator training programs have been generated. The result is that a successful education and training program can create an environment favorable to the safe and effective implementation of a remote equipment program in a nuclear facility.

Palau, G.L.; Auclair, K.D.

1986-01-01T23:59:59.000Z

395

Alternative Fuels Data Center: Biodiesel Production and Blending Equipment  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Biodiesel Production Biodiesel Production and Blending Equipment Tax Credit to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on Google Bookmark Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on Delicious Rank Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on Digg Find More places to share Alternative Fuels Data Center: Biodiesel Production and Blending Equipment Tax Credit on AddThis.com... More in this section... Federal State

396

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Requirements to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Requirements on AddThis.com... More in this section... Federal State Advanced Search

397

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on Digg Find More places to share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - LADWP on AddThis.com... More in this section... Federal

398

Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Mandatory Electric Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards to someone by E-mail Share Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on Facebook Tweet about Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on Twitter Bookmark Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on Google Bookmark Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on Delicious Rank Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on Digg Find More places to share Alternative Fuels Data Center: Mandatory Electric Vehicle Supply Equipment (EVSE) Building Standards on

399

Level of Automation Effects on Situation Awareness and Functional Specificity in Automation Reliance.  

E-Print Network [OSTI]

??This thesis investigates the relationships between performance, workload, and situation awareness at varying levels of automation. The relationships observed in this study are compared to… (more)

Smith, Adam

2012-01-01T23:59:59.000Z

400

Distributed Energy Resources for Carbon Emissions Mitigation  

E-Print Network [OSTI]

solar electric and thermal equipment, and energy storage - collectively termed distributed energy resources (energy resources (DER) such as on-site fossil-fuel based combined heat and power (CHP), thermally- activated cooling, photovoltaics, solar

Firestone, Ryan; Marnay, Chris

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

LANL to certify automated influenza surveillance system  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

LANL to certify automated influenza surveillance system LANL to certify automated influenza surveillance system LANL to certify automated influenza surveillance system A compact automated system for surveillance and screening of potential pandemic strains of influenza and other deadly infectious diseases is a step closer to reality. January 31, 2011 Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy sources, to plasma physics and new materials. Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy

402

Automated visual inspection of rolled metal surfaces  

Science Journals Connector (OSTI)

A prototype for an automated visual on-line metal strip inspection system is described. The system is capable of both detecting and classifying surface defects in copper alloy strips, and it has been installed...

Timo Piironen; Olli Silven; Matti Pietikäinen…

1990-01-01T23:59:59.000Z

403

Automated intrusion recovery for web applications  

E-Print Network [OSTI]

In this dissertation, we develop recovery techniques for web applications and demonstrate that automated recovery from intrusions and user mistakes is practical as well as effective. Web applications play a critical role ...

Chandra, Ramesh, Ph. D. Massachusetts Institute of Technology

2013-01-01T23:59:59.000Z

404

Preface: Cognitive Engineering in Automated Systems Design  

E-Print Network [OSTI]

Preface: Cognitive Engineering in Automated Systems Design This special issue was motivated by an apparent paucity of research on applications of cognitive engineering principles in the design of complex systems including mainte- nance, manufacturing, and transportation systems. Cognitive engineering

Kaber, David B.

405

Honeywell modular automation system computer software documentation  

SciTech Connect (OSTI)

This document provides a Computer Software Docuemntation for a new Honeywell Modular Automation System (MAS) being installed in the Plutonium Finishing Plant (PFP). This system will be used to control new thermal stabilization furnaces in HA-21I.

Cunningham, L.T.

1997-01-20T23:59:59.000Z

406

ZigBee Smart Home Automation Systems  

Science Journals Connector (OSTI)

This chapter summarizes a completed UK government funded project, the indeedNET ZigBee home automation system, which heralds a milestone in the ... energy saving devices with the potential to help home owners and...

Shuang-Hua Yang

2014-01-01T23:59:59.000Z

407

Graphic update of automated logic diagrams  

Science Journals Connector (OSTI)

The Automated Logic Diagram, or ALD, is a well defined document prepared by engineers to specify the design of a machine. 1 The document is coded for computer input by highly trained transcription personnel. Changes or corrections ...

Richard J. Uhlik

1968-07-01T23:59:59.000Z

408

Design automation for microfluidics-based biochips  

Science Journals Connector (OSTI)

Advances in microfluidics technology offer exciting possibilities in the realm of enzymatic analysis, DNA analysis, proteomic analysis involving proteins and peptides, immunoassays, implantable drug delivery devices, and environmental toxicity monitoring. ... Keywords: Microfluidics, biochips, design automation

Krishnendu Chakrabarty; Jun Zeng

2005-10-01T23:59:59.000Z

409

Distributed Algorithms Distributed Transactions  

E-Print Network [OSTI]

Algorithms© Gero Mühl 8 Concurrency Control serial RC (ReCoverable) ACA (Avoiding Cascading Aborts) ST (StricDistributed Algorithms Distributed Transactions PD Dr.-Ing. Gero Mühl Kommunikations- und Betriebssysteme Fakultät für Elektrotechnik u. Informatik Technische Universität Berlin #12;Distributed Algorithms

Wichmann, Felix

410

Automating Logic Rectification by Approximate SPFDs  

Science Journals Connector (OSTI)

In the digital VLSI cycle, a netlist is often modified to correct design errors, perform small specification changes or implement incremental rewiring-based optimization operations. Most existing automated logic rectification tools use a small set of ... Keywords: SAT-based algorithm, approximate SPFD, digital VLSI cycle, design errors, incremental rewiring-based optimization operations, automated logic rectification tools, predefined logic transformations, memory/time explosion problem

Yu-Shen Yang; S. Sinha; A. Veneris; R. K. Brayton

2007-01-01T23:59:59.000Z

411

Analysis of Open Automated Demand Response Deployments in California and Guidelines to Transition to Industry Standards  

E-Print Network [OSTI]

to  Automated  Demand   Response  and  the  OpenADR  ®  Automated  Demand  Response  Program.   https://Data  for  Automated  Demand  Response  in  Commercial  

Ghatikar, Girish

2014-01-01T23:59:59.000Z

412

Open Automated Demand Response Technologies for Dynamic Pricing and Smart Grid  

E-Print Network [OSTI]

for Automated Demand Response in Commercial Buildings. ” In2010. “Open Automated Demand Response Dynamic Pricing2009. “Open Automated Demand Response Communications

Ghatikar, Girish

2010-01-01T23:59:59.000Z

413

Explorations of Space-Charge Limits in Parallel-Plate Diodes and Associated Techniques for Automation  

E-Print Network [OSTI]

and Associated Techniques for Automation by Benjamin Ragan-and Associated Techniques for Automation Copyright 2013 byand Associated Techniques for Automation by Benjamin Ragan-

Ragan-Kelley, Benjamin

2013-01-01T23:59:59.000Z

414

Demonstration of Datacenter Automation Software and Hardware (DASH) at the California Franchise Tax Board  

E-Print Network [OSTI]

of Datacenter Automation Software and Hardware (DASH) at theof Datacenter Automation Software and Hardware (DASH) at theprotocol for building automation and control networks. It is

Bell, Geoffrey C.

2010-01-01T23:59:59.000Z

415

Automation for on-line remote-control in-situ electron microscopy  

E-Print Network [OSTI]

Pfefferkorn Conference (1996) Automation for On-Line Remote-Pfefferkorn Conference (1996) Automation for On-Line Remote-by incorporating local automation of stage control and

1996-01-01T23:59:59.000Z

416

Automated Demand Response Technologies and Demonstration in New York City using OpenADR  

E-Print Network [OSTI]

EMCS Vendor and Product Automated Logic Control RemoteBuildings Integrator, Automated Logic Corporation’s WebCTRLIntegrator (EBI), Automated Logic Corporation’s WebCTRL® ,

Kim, Joyce Jihyun

2014-01-01T23:59:59.000Z

417

Electrical Metering Equipment and Sensors Appendix D -Electrical Metering Equipment and Sensors  

E-Print Network [OSTI]

Appendix D ­ Electrical Metering Equipment and Sensors #12;D.1 Appendix D - Electrical Metering schedules, and view system status from the convenience of a standard web-browser. D.2 Metering Data Logger

418

Sample Environment Equipment Categories - ORNL Neutron Sciences  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Home › Instruments › Sample Environment Home › Instruments › Sample Environment Sample Environment: Categories of Equipment All Ancillary Equipment Auto Changer Closed Cycle Refrigerators Closed Cycle Refrigerators - Bottom Loading Closed Cycle Refrigerators - Top Loading Furnaces Gas Handling Gas Panel High Pressure Systems Liquid Helium Cryostats Magnet Systems Other Special Environments Sample Cell Sample Stick Ultra Low Temperature Devices Sample Environment: by Beam Line All BL-11A-POWGEN BL-11B-MANDI BL-12-TOPAZ BL-13-Fundamental Neutron Physics Beam Line BL-14A-BL-14A BL-14B-HYSPEC BL-15-Neutron Spin Echo (NSE) BL-16B-VISION BL-17-SEQUOIA BL-18-ARCS BL-1A-TOF-USANS BL-1B-NOMAD BL-2-BASIS BL-3-SNAP BL-4A-Magnetism Reflectometer BL-4B-Liquids Reflectometer BL-5-Cold Neutron Chopper Spectrometer (CNCS) BL-6-EQ-SANS

419

Laboratory Equipment Donation Program - Guidelines/FAQ  

Office of Scientific and Technical Information (OSTI)

Frequently Asked Questions Frequently Asked Questions Who is eligible to apply for equipment? Due to budget constraints, the free shipping program for "high need schools" has been discontinued; and middle and high schools are no longer eligible to participate in the Laboratory Equipment Donation Program (LEDP) program. Participation in the LEDP is limited to accredited, post graduate, degree granting institutions including universities, colleges, junior colleges, technical institutes, museums, or hospitals, located in the U.S. and interested in establishing or upgrading energy-oriented educational programs in the life, physical, and environmental sciences and in engineering is eligible to apply. An energy-oriented program is defined as an academic research activity dealing primarily or entirely in

420

Process Equipment Cost Estimation, Final Report  

Office of Scientific and Technical Information (OSTI)

Process Equipment Cost Estimation Process Equipment Cost Estimation Final Report January 2002 H.P. Loh U.S. Department of Energy National Energy Technology Laboratory P.O. Box 10940, 626 Cochrans Mill Road Pittsburgh, PA 15236-0940 and P.O. Box 880, 3610 Collins Ferry Road Morgantown, WV 26507-0880 and Jennifer Lyons and Charles W. White, III EG&G Technical Services, Inc. 3604 Collins Ferry Road, Suite 200 Morgantown, WV 26505 DOE/NETL-2002/1169 ii Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus,

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Documentation Requirements for Pressurized Experiment Equipment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Documentation Requirements for Pressurized Experiment Apparatus Documentation Requirements for Pressurized Experiment Apparatus PSSC NOTE01 15-Jan-2013 When bringing a piece of apparatus to the APS for an experiment that will involve pressure, whether it is to be used on a beamline during a measurement or in a laboratory to prepare the sample prior to the experiment, the hazards associated with the equipment must be reviewed. To review the equipment and make any recommendations, a certain level of documentation must be provided by the experimenter. The length and depth of the documentation should be commensurate with the complexity of the system. 1. Description of apparatus a. Description of the assembly and operation of the system. b. State the maximum working pressure, working fluid (liquid or gas) used to

422

BCM 1 Equipment Inventory | Sample Preparation Laboratories  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

1 Equipment Inventory 1 Equipment Inventory « Biology Chemistry & Material Science Laboratory 1 Title Equipment Type Description Agilent 8453 UV-Vis Spectrophotometer Analytical Agilent 8453 UV-VIS diode-array spectrophotometer. Wavelength range 190-1100 nm with a 1 nm optical slit width. Disposable plastic cuvettes are available in the lab, and quartz cuvettes and microcuvettes are available on a check-out basis. Beckman GPKR Centrifuge Centrifuge Beckman GPKR refrigerated centrifuge with fixed angle rotor, 8000 rpm max speed, temperature range -10°C to 40°C, fits 50mL tubes. Corning 430 pH Meter pH Meter The Corning 430 pH meter is designed to handle laboratory applications from the most routine to the highly complex. Encased in spill-resistant housings and feature chemical-resistant, sealed keypad. Model 430 (pH range 0.00 to 14.00) is a basic, yet reliable meter providing accurate, efficient digital measurements. Offers simplified, four-button operation, automatic calibration and temperature compensation, % slope readout, self-diagnostics test on powerup and analog recorder output. Unique LCD shows pH, mV

423

Plant design: Integrating Plant and Equipment Models  

SciTech Connect (OSTI)

Like power plant engineers, process plant engineers must design generating units to operate efficiently, cleanly, and profitably despite fluctuating costs for raw materials and fuels. To do so, they increasingly create virtual plants to enable evaluation of design concepts without the expense of building pilot-scale or demonstration facilities. Existing computational models describe an entire plant either as a network of simplified equipment models or as a single, very detailed equipment model. The Advanced Process Engineering Co-Simulator (APECS) project (Figure 5) sponsored by the U.S. Department of Energy's National Energy Technology Laboratory (NETL) seeks to bridge the gap between models by integrating plant modeling and equipment modeling software. The goal of the effort is to provide greater insight into the performance of proposed plant designs. The software integration was done using the process-industry standard CAPE-OPEN (Computer Aided Process Engineering–Open), or CO interface. Several demonstration cases based on operating power plants confirm the viability of this co-simulation approach.

Sloan, David (Alstrom Power); Fiveland, Woody (Alstrom Power); Zitney, S.E.; Osawe, Maxwell (Ansys, Inc.)

2007-08-01T23:59:59.000Z

424

New Remote Method for Estimation of Contamination Levels of Reactor Equipment - 13175  

SciTech Connect (OSTI)

Projects for decommissioning of shutdown reactors and reactor facilities carried out in several countries, including Russia. In the National Research Centre 'Kurchatov Institute' decontamination and decommissioning of the research reactor MR (Material Testing Reactor) has been initiated. The research reactor MR has a long history and consists of nine loop facilities for experiments with different kinds of fuel. During the operation of main and auxiliary equipment of reactors it was subjected to strong radioactive contamination. The character of this contamination requires individual strategies for the decontamination work. This requires information about the character of the distribution of radioactive contamination of equipment in the premises. A detailed radiation survey of these premises using standard dosimetric equipment is almost impossible because of high levels of radiation and high-density of the equipment that does not allow identifying the most active fragments using standard tools of measurement. The problem can be solved using the method of remote measurements of distribution of radioactivity with help of the collimated gamma-ray detectors. For radiation surveys of the premises of loop installations remotely operated spectrometric collimated system was used [1, 2, 3]. As a result of the work, maps of the distribution of activity and dose rate for surveyed premises were plotted and superimposed on its photo. The new results of measurements in different areas of the reactor and at its loop installations, with emphasis on the radioactive survey of highly-contaminated samples, are presented. (authors)

Danilovich, Alexey; Ivanov, Oleg; Potapov, Victor; Semenov, Sergey; Semin, Ilya; Smirnov, Sergey; Stepanov, Vyacheslav; Volkovich, Anatoly [National Research Centre 'Kurchatov Institute', Moscow (Russian Federation)] [National Research Centre 'Kurchatov Institute', Moscow (Russian Federation)

2013-07-01T23:59:59.000Z

425

Mixed integer model for optimizing equipment scheduling and overburden transport in a surface coal mining operation  

SciTech Connect (OSTI)

The lack of available techniques prompted the development of a mixed integer model to optimize the scheduling of equipment and the distribution of overburden in a typical mountaintop removal operation. Using this format, a (0-1) integer model and transportation model were constructed to determine the optimal equipment schedule and optimal overburden distribution, respectively. To solve this mixed integer program, the model was partitioned into its binary and real-valued components. Each problem was successively solved and their values added to form estimates of the value of the mixed integer program. Optimal convergence was indicated when the difference between two successive estimates satisfied some pre-specific accuracy value. The performance of the mixed integer model was tested against actual field data to determine its practical applications. To provide the necessary input information, production data was obtained from a single seam, mountaintop removal operation located in the Appalachian coal field. As a means of analyzing the resultant equipment schedule, the total idle time was calculated for each machine type and each lift location. Also, the final overburden assignments were analyzed by determining the distribution of spoil material for various overburden removal productivities. Subsequent validation of the mixed integer model was conducted in two distinct areas. The first dealt with changes in algorithmic data and their effects on the optimality of the model. The second area concerned variations in problem structure, specifically those dealing with changes in problem size and other user-inputed values such as equipment productivities or required reclamation.

Goodman, G.V.R.

1987-01-01T23:59:59.000Z

426

Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Biodiesel Equipment Biodiesel Equipment and Fuel Tax Exemption to someone by E-mail Share Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on Facebook Tweet about Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on Twitter Bookmark Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on Google Bookmark Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on Delicious Rank Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on Digg Find More places to share Alternative Fuels Data Center: Biodiesel Equipment and Fuel Tax Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Biodiesel Equipment and Fuel Tax Exemption

427

Alternative Fuels Data Center: Installing New E85 Equipment  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Installing New E85 Installing New E85 Equipment to someone by E-mail Share Alternative Fuels Data Center: Installing New E85 Equipment on Facebook Tweet about Alternative Fuels Data Center: Installing New E85 Equipment on Twitter Bookmark Alternative Fuels Data Center: Installing New E85 Equipment on Google Bookmark Alternative Fuels Data Center: Installing New E85 Equipment on Delicious Rank Alternative Fuels Data Center: Installing New E85 Equipment on Digg Find More places to share Alternative Fuels Data Center: Installing New E85 Equipment on AddThis.com... More in this section... Ethanol Basics Benefits & Considerations Stations Locations Infrastructure Development Business Case Equipment Options Equipment Installation Codes, Standards, & Safety Vehicles Laws & Incentives

428

Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Blending Blending Equipment Tax Exemption to someone by E-mail Share Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on Facebook Tweet about Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on Twitter Bookmark Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on Google Bookmark Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on Delicious Rank Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on Digg Find More places to share Alternative Fuels Data Center: Biofuel Blending Equipment Tax Exemption on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Biofuel Blending Equipment Tax Exemption Qualified equipment used for storing and blending petroleum-based fuel with

429

High performance gamma measurements of equipment retrieved from Hanford high-level nuclear waste tanks  

SciTech Connect (OSTI)

The cleanup of high level defense nuclear waste at the Hanford site presents several progressive challenges. Among these is the removal and disposal of various components from buried active waste tanks to allow new equipment insertion or hazards mitigation. A unique automated retrieval system at the tank provides for retrieval, high pressure washing, inventory measurement, and containment for disposal. Key to the inventory measurement is a three detector HPGe high performance gamma spectroscopy system capable of recovering data at up to 90% saturation (200,000 counts per second). Data recovery is based on a unique embedded electronic pulser and specialized software to report the inventory. Each of the detectors have different shielding specified through Monte Carlo simulation with the MCNP program. This shielding provides performance over a dynamic range of eight orders of magnitude. System description, calibration issues and operational experiences are discussed.

Troyer, G.L.

1997-03-17T23:59:59.000Z

430

Direct Liquid Cooling for Electronic Equipment  

SciTech Connect (OSTI)

This report documents a demonstration of an electronic--equipment cooling system in the engineering prototype development stage that can be applied in data centers. The technology provides cooling by bringing a water--based cooling fluid into direct contact with high--heat--generating electronic components. This direct cooling system improves overall data center energy efficiency in three ways: High--heat--generating electronic components are more efficiently cooled directly using water, capturing a large portion of the total electronic equipment heat generated. This captured heat reduces the load on the less--efficient air--based data center room cooling systems. The combination contributes to the overall savings. The power consumption of the electronic equipment internal fans is significantly reduced when equipped with this cooling system. The temperature of the cooling water supplied to the direct cooling system can be much higher than that commonly provided by facility chilled water loops, and therefore can be produced with lower cooling infrastructure energy consumption and possibly compressor-free cooling. Providing opportunities for heat reuse is an additional benefit of this technology. The cooling system can be controlled to produce high return water temperatures while providing adequate component cooling. The demonstration was conducted in a data center located at Lawrence Berkeley National Laboratory in Berkeley, California. Thirty--eight servers equipped with the liquid cooling system and instrumented for energy measurements were placed in a single rack. Two unmodified servers of the same configuration, located in an adjacent rack, were used to provide a baseline. The demonstration characterized the fraction of heat removed by the direct cooling technology, quantified the energy savings for a number of cooling infrastructure scenarios, and provided information that could be used to investigate heat reuse opportunities. Thermal measurement data were used with data center energy use modeling software to estimate overall site energy use. These estimates show that an overall data center energy savings of approximately 20 percent can be expected if a center is retrofitted as specified in the models used. Increasing the portion of heat captured by this technology is an area suggested for further development.

Coles, Henry; Greenberg, Steve

2014-03-01T23:59:59.000Z

431

Automated diagnostics scoping study. Final report  

SciTech Connect (OSTI)

The objective of the Automated Diagnostics Scoping Study was to investigate the needs for diagnostics in building operation and to examine some of the current technologies in automated diagnostics that can address these needs. The study was conducted in two parts. In the needs analysis, the authors interviewed facility managers and engineers at five building sites. In the technology survey, they collected published information on automated diagnostic technologies in commercial and military applications as well as on technologies currently under research. The following describe key areas that the authors identify for the research, development, and deployment of automated diagnostic technologies: tools and techniques to aid diagnosis during building commissioning, especially those that address issues arising from integrating building systems and diagnosing multiple simultaneous faults; technologies to aid diagnosis for systems and components that are unmonitored or unalarmed; automated capabilities to assist cause-and-effect exploration during diagnosis; inexpensive, reliable sensors, especially those that expand the current range of sensory input; technologies that aid predictive diagnosis through trend analysis; integration of simulation and optimization tools with building automation systems to optimize control strategies and energy performance; integration of diagnostic, control, and preventive maintenance technologies. By relating existing technologies to perceived and actual needs, the authors reached some conclusions about the opportunities for automated diagnostics in building operation. Some of a building operator`s needs can be satisfied by off-the-shelf hardware and software. Other needs are not so easily satisfied, suggesting directions for future research. Their conclusions and suggestions are offered in the final section of this study.

Quadrel, R.W.; Lash, T.A.

1994-06-01T23:59:59.000Z

432

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE)  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Electric Vehicle Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) Rebate - Indiana Michigan Power on Digg Find More places to share Alternative Fuels Data Center: Electric

433

Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Highway Electric Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements to someone by E-mail Share Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Facebook Tweet about Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Twitter Bookmark Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Google Bookmark Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Delicious Rank Alternative Fuels Data Center: Highway Electric Vehicle Supply Equipment (EVSE) Installation Requirements on Digg Find More places to share Alternative Fuels Data Center: Highway

434

Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and  

Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

Vehicle Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations to someone by E-mail Share Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations on Facebook Tweet about Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations on Twitter Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations on Google Bookmark Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations on Delicious Rank Alternative Fuels Data Center: Electric Vehicle Supply Equipment (EVSE) and Battery Exchange Station Regulations on Digg Find More places to share Alternative Fuels Data Center: Electric

435

ISA Approves Standard for Wireless Automation in Process Control  

Broader source: Energy.gov (indexed) [DOE]

ISA Approves Standard for Wireless Automation in Process Control ISA Approves Standard for Wireless Automation in Process Control Applications ISA Approves Standard for Wireless Automation in Process Control Applications On September 9, the Standards and Practices Board of the International Society for Automation (ISA) approved the ISA-100.11a wireless standard, "Wireless Systems for Industrial Automation: Process Control and Related Applications," making it an official ISA standard. ISA Approves Standard for Wireless Automation in Process Control Applications More Documents & Publications DOE/OE National SCADA Test Bed Fiscal Year 2009 Work Plan Wireless System Considerations When Implementing NERC Critical Infrastructure Protection Standards Control Systems Security Standards: Accomplishments And Impacts

436

Automated Monitoring System for Waste Disposal Sites and Groundwater  

SciTech Connect (OSTI)

A proposal submitted to the U.S. Department of Energy (DOE), Office of Science and Technology, Accelerated Site Technology Deployment (ASTD) program to deploy an automated monitoring system for waste disposal sites and groundwater, herein referred to as the ''Automated Monitoring System,'' was funded in fiscal year (FY) 2002. This two-year project included three parts: (1) deployment of cellular telephone modems on existing dataloggers, (2) development of a data management system, and (3) development of Internet accessibility. The proposed concept was initially (in FY 2002) to deploy cellular telephone modems on existing dataloggers and partially develop the data management system at the Nevada Test Site (NTS). This initial effort included both Bechtel Nevada (BN) and the Desert Research Institute (DRI). The following year (FY 2003), cellular modems were to be similarly deployed at Sandia National Laboratories (SNL) and Los Alamos National Laboratory (LANL), and the early data management system developed at the NTS was to be brought to those locations for site-specific development and use. Also in FY 2003, additional site-specific development of the complete system was to be conducted at the NTS. To complete the project, certain data, depending on site-specific conditions or restrictions involving distribution of data, were to made available through the Internet via the DRI/Western Region Climate Center (WRCC) WEABASE platform. If the complete project had been implemented, the system schematic would have looked like the figure on the following page.

S. E. Rawlinson

2003-03-01T23:59:59.000Z

437

Open Automated Demand Response Communications in Demand Response for Wholesale Ancillary Services  

SciTech Connect (OSTI)

The Pacific Gas and Electric Company (PG&E) is conducting a pilot program to investigate the technical feasibility of bidding certain demand response (DR) resources into the California Independent System Operator's (CAISO) day-ahead market for ancillary services nonspinning reserve. Three facilities, a retail store, a local government office building, and a bakery, are recruited into the pilot program. For each facility, hourly demand, and load curtailment potential are forecasted two days ahead and submitted to the CAISO the day before the operation as an available resource. These DR resources are optimized against all other generation resources in the CAISO ancillary service. Each facility is equipped with four-second real time telemetry equipment to ensure resource accountability and visibility to CAISO operators. When CAISO requests DR resources, PG&E's OpenADR (Open Automated DR) communications infrastructure is utilized to deliver DR signals to the facilities energy management and control systems (EMCS). The pre-programmed DR strategies are triggered without a human in the loop. This paper describes the automated system architecture and the flow of information to trigger and monitor the performance of the DR events. We outline the DR strategies at each of the participating facilities. At one site a real time electric measurement feedback loop is implemented to assure the delivery of CAISO dispatched demand reductions. Finally, we present results from each of the facilities and discuss findings.

Kiliccote, Sila; Piette, Mary Ann; Ghatikar, Girish; Koch, Ed; Hennage, Dan; Hernandez, John; Chiu, Albert; Sezgen, Osman; Goodin, John

2009-11-06T23:59:59.000Z

438

Equipment design guidance document for flammable gas waste storage tank new equipment  

SciTech Connect (OSTI)

This document is intended to be used as guidance for design engineers who are involved in design of new equipment slated for use in Flammable Gas Waste Storage Tanks. The purpose of this document is to provide design guidance for all new equipment intended for application into those Hanford storage tanks in which flammable gas controls are required to be addressed as part of the equipment design. These design criteria are to be used as guidance. The design of each specific piece of new equipment shall be required, as a minimum to be reviewed by qualified Unreviewed Safety Question evaluators as an integral part of the final design approval. Further Safety Assessment may be also needed. This guidance is intended to be used in conjunction with the Operating Specifications Documents (OSDs) established for defining work controls in the waste storage tanks. The criteria set forth should be reviewed for applicability if the equipment will be required to operate in locations containing unacceptable concentrations of flammable gas.

Smet, D.B.

1996-04-11T23:59:59.000Z

439

n-Tiered Test Automation Architecture for Agile Software Systems  

Science Journals Connector (OSTI)

Abstract This paper introduces a multi-tiered test automation architecture to optimize test automation in an Agile software development environment while increasing both the test coverage and depth of each tier. Test Automation is the act of converting manual test cases into automated scripts that can be executed autonomously. In general, testing accounts for roughly 60% of the overall development budget and approximately 50% of that is attributed to regression testing. In recent years software organizations have begun migrating to Agile software development practices and automated testing in hopes of reducing the cost, lengthy regression cycles, and time to market. Traditionally, test automation is conducted on stable, non-changing applications. In an Agile environment where the code constantly changes, automated test cases become obsolete and must constantly be refactored in order to provide meaningful feedback about the system's quality. In most instances the cost of maintenance of automated test code completely overshadows the entire automation effort and negates any possible Return on Investment (RoI). An n-Tiered Test Automation Architecture seeks to retain the RoI by abstracting the automation project into separate distinct tiers; Presentation, Business, Data, and Services. These abstractions allow automated testing to continue providing feedback despite the constant revision of the system. A case study was conducted using this method and the observations showed that the automation architecture was resilient to change while increasing the test coverage, the depth of testing, and the overall quality of the application under test.

Patrick Day

2014-01-01T23:59:59.000Z

440

Emissions characteristics of modern oil heating equipment  

SciTech Connect (OSTI)

Over the last 10 years there have been some very interesting developments in oil heating. These include higher static pressure burners, air atomizing nozzles, low firing rate nozzles, low heat loss combustion chambers and condensing boilers and furnaces. The current data base on the emissions characteristics of oil-fired residential heating equipment is based primarily on data taken in the 1970's. The objective of the work described in this report is to evaluate the effects of recent developments in oil-fired equipment on emissions. Detailed emissions measurements have been made on a number of currently available residential oil burners and whole systems selected to represent recent development trends. Some additional data was taken with equipment which is in the prototype stage. These units are a prevaporizing burner and a retention head burner modified with an air atomizing nozzle. Measurements include No{sub x}, smoke numbers, CO, gas phase hydrocarbon emissions and particulate mass emission rates. Emissions of smoke, CO and hydrocarbons were found to be significantly greater under cyclic operation for all burners tested. Generally, particulate emission rates were found to be 3 to 4 times greater in cyclic operation than in steady state. Air atomized burners were found to be capable of operation at much lower excess air levels than pressure atomized burners without producing significant amounts of smoke. As burner performance is improved, either through air atomization or prevaporization of the fuel, there appears to be a general trend towards producing CO at lower smoke levels as excess air is decreased. The criteria of adjusting burners for trace smoke may need to be abandoned for advanced burners and replaced with an adjustment for specific excess air levels. 17 refs., 15 figs., 6 tabs.

Krajewski, R.; Celebi, Y.; Coughlan, R.; Butcher, T.; McDonald, R.J.

1990-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "distribution automation equipment" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Laboratory Equipment Donation Program - LEDP Widget Code  

Office of Scientific and Technical Information (OSTI)

Widget Inclusion Code Widget Inclusion Code Copy the code below and paste it to your website or blog: