Sample records for distributed systems integration

  1. Distributed Energy Systems Integration Group (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2009-10-01T23:59:59.000Z

    Factsheet developed to describe the activites of the Distributed Energy Systems Integration Group within NREL's Electricity, Resources, and Buildings Systems Integration center.

  2. Development of an Integrated Distribution Management System

    SciTech Connect (OSTI)

    Schatz, Joe E.

    2010-10-20T23:59:59.000Z

    This final report details the components, functionality, costs, schedule and benefits of developing an Integrated Distribution Management System (IDMS) for power distribution system operation. The Distribution Automation (DA) and Supervisory Control and Data Acquisition (SCADA) systems used by electric power companies to manage the distribution of electric power to retail energy consumers are vital components of the Nation’s critical infrastructure. Providing electricity is an essential public service and a disruption in that service, if not quickly restored, could threaten the public safety and the Nation’s economic security. Our Nation’s economic prosperity and quality of life have long depended on the essential services that utilities provide; therefore, it is necessary to ensure that electric utilities are able to conduct their operations safely and efficiently. A fully integrated technology of applications is needed to link various remote sensing, communications and control devices with other information tools that help guide Power Distribution Operations personnel. A fully implemented IDMS will provide this, a seamlessly integrated set of applications to raise electric system operating intelligence. IDMS will enhance DA and SCADA through integration of applications such as Geographic Information Systems, Outage Management Systems, Switching Management and Analysis, Operator Training Simulator, and other Advanced Applications, including unbalanced load flow and fault isolation/service restoration. These apps are capable of utilizing and obtaining information from appropriately installed DER, and by integrating disparate systems, the Distribution Operators will benefit from advanced capabilities when analyzing, controlling and operating the electric system.

  3. Integrated Distribution Management System for Alabama Principal Investigator

    SciTech Connect (OSTI)

    Schatz, Joe

    2013-03-31T23:59:59.000Z

    Southern Company Services, under contract with the Department of Energy, along with Alabama Power, Alstom Grid (formerly AREVA T&D) and others moved the work product developed in the first phase of the Integrated Distribution Management System (IDMS) from “Proof of Concept” to true deployment through the activity described in this Final Report. This Project – Integrated Distribution Management Systems in Alabama – advanced earlier developed proof of concept activities into actual implementation and furthermore completed additional requirements to fully realize the benefits of an IDMS. These tasks include development and implementation of a Distribution System based Model that enables data access and enterprise application integration.

  4. Concept of SPDS integrated into Distributed Computer System (DCS)

    SciTech Connect (OSTI)

    Anikanov, S. S. [Westinghouse LLC, 4350 Northern Pike, Monroeville, PA 15146 (United States)

    2006-07-01T23:59:59.000Z

    Implementation of the Safety Parameter Display System (SPDS) during the NPP modernization activities or for the new plant imposes certain requirements on the system design. In many cases, such SPDS system functionality is integrated into the non-safety part of the Distributed Computer System (DCS). The SPDS becomes organically embedded into the major I and C hardware and application software. However, from the licensing perspective, SPDS shall be designed as a functional entity which satisfies industry standards and as such imposes requirements to the other plant MMI systems. 'Other MMI systems' that are used to support the operating staff during normal, abnormal and emergency plant conditions include Main Control Room Workstations, Shared Wall Panel Display (WPD), and other information systems. The SPDS resources, used to address the system requirements, also include the Emergency Response Facilities (TSC, Emergency on-site Facilities, and Emergency off-site Facilities). (authors)

  5. Integration of HVAC System Design with Simplified Duct Distribution...

    Energy Savers [EERE]

    about this Top Innovation. See an example of this Top Innovation in action. Find more case studies of Building America projects across the country that integrate HVAC system...

  6. Robust control strategy for PV system integration in distribution systems M.J. Hossain a,

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Robust control strategy for PV system integration in distribution systems M.J. Hossain a, , T t s " Robust control provides flexible photovoltaic (PV) accommodations. " A robust PV control can significantly enhance the penetration level. " The change in volatile PV generations is considered

  7. Integrating Bulk-Data Transfer into the Aurora Distributed Shared Data System

    E-Print Network [OSTI]

    Lu, Paul

    Integrating Bulk-Data Transfer into the Aurora Distributed Shared Data System Paul Lu Dept version, with corrections to JPDC proofs 1 #12;Running Head: Integrating Bulk-Data Transfer into Aurora-1071 Web: http://www.cs.ualberta.ca/~paullu/ Abstract The Aurora distributed shared data system implements

  8. THE INTEGRATION AND CONTROL OF MULTIFUNCTIONAL STATIONARY PV-BATTERY SYSTEMS IN SMART DISTRIBUTION GRID

    E-Print Network [OSTI]

    Berning, Torsten

    ) in presence of photovoltaic (PV) panel on the view of techno economic optimal sizing taking the considerationTHE INTEGRATION AND CONTROL OF MULTIFUNCTIONAL STATIONARY PV-BATTERY SYSTEMS IN SMART DISTRIBUTION stationary battery energy storage systems (BESS) in the public low-voltage distribution grid in order

  9. System Integration of Distributed Power for Complete Building Systems: Phase 1 Report

    SciTech Connect (OSTI)

    Kramer, R.

    2003-12-01T23:59:59.000Z

    This report describes NiSource Energy Technologies Inc.'s base year of a planned 3-year effort to advance distributed power development, deployment, and integration. Its long-term goal is to design ways to extend distributed generation into the physical design and controls of buildings. NET worked to meet this goal through advances in the implementation and control of CHP systems in end-user environments and a further understanding of electric interconnection and siting issues. Important results from the first year were a survey of the state of the art of interconnection issues associated with distributed generation, a survey of the local zoning requirements for the NiSource service territory, and the acquisition of data about the operation, reliability, interconnection, and performance of CHP systems and components of two test sites.

  10. Distributed Integral Action: Stability Analysis and Frequency Control of Power Systems

    E-Print Network [OSTI]

    Johansson, Karl Henrik

    propose a fully decentralized frequency control algorithm for electrical power systems. We model the powerDistributed Integral Action: Stability Analysis and Frequency Control of Power Systems Martin frequency control of electrical power systems. We show that the proposed algorithm can attenuate step

  11. Operation and Control of Distribution Systems with high level integration of Renewable Generation units

    E-Print Network [OSTI]

    Bak-Jensen, Birgitte

    models Probabilistic methodologies are being applied to power system analysis since 70' [9] becauseOperation and Control of Distribution Systems with high level integration of Renewable Generation. Diagonal 649 Pavelló A, 08028 Barcelona, Spain Summary Traditional power systems have a hierarchical

  12. Integration of HVAC System Design with Simplified Duct Distribution -

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking of BlytheDepartmentEnergy Integrated EnergyIntegratedAdaptingBuilding

  13. Sandia National Laboratories: Distribution Grid Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Distribution Grid Integration ECIS-Princeton Power Systems, Inc.: Demand Response Inverter On March 19, 2013, in DETL, Distribution Grid Integration, Energy, Energy Surety,...

  14. The integration of renewable energy sources into electric power distribution systems. Volume 1: National assessment

    SciTech Connect (OSTI)

    Barnes, P.R.; Van Dyke, J.W. [Oak Ridge National Lab., TN (United States); Tesche, F.M. [6714 Norway Road, Dallas, TX (United States); Zaininger, H.W. [Zaininger Engineering Co., San Jose, CA (United States)

    1994-06-01T23:59:59.000Z

    Renewable energy technologies such as photovoltaic, solar thermal electricity, and wind turbine power are environmentally beneficial sources of electric power generation. The integration of renewable energy sources into electric power distribution systems can provide additional economic benefits because of a reduction in the losses associated with transmission and distribution lines. Benefits associated with the deferment of transmission and distribution investment may also be possible for cases where there is a high correlation between peak circuit load and renewable energy electric generation, such as photovoltaic systems in the Southwest. Case studies were conducted with actual power distribution system data for seven electric utilities with the participation of those utilities. Integrating renewable energy systems into electric power distribution systems increased the value of the benefits by about 20 to 55% above central station benefits in the national regional assessment. In the case studies presented in Vol. II, the range was larger: from a few percent to near 80% for a case where costly investments were deferred. In general, additional savings of at least 10 to 20% can be expected by integrating at the distribution level. Wind energy systems were found to be economical in good wind resource regions, whereas photovoltaic systems costs are presently a factor of 2.5 too expensive under the most favorable conditions.

  15. NiSource Energy Technologies Inc.: System Integration of Distributed Power for Complete Building Systems

    SciTech Connect (OSTI)

    Not Available

    2003-10-01T23:59:59.000Z

    Summarizes NiSource Energy Technologies' work under contract to DOE's Distribution and Interconnection R&D. Includes studying distributed generation interconnection issues and CHP system performance.

  16. NREL: Energy Systems Integration Facility - Fuel Distribution Buses

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | NationalWebmaster ToStaffCapabilitiesFuel

  17. NREL: Energy Systems Integration Facility - Thermal Distribution Bus

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit |Infrastructure The foundation ofThermal

  18. Systems Integration | ornl.gov

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Systems Integration SHARE Systems Integration The Distributed Energy Communications and Controls (DECC) Laboratory offers a unique test bed for testing distributed energy...

  19. The integration of renewable energy sources into electric power distribution systems. Volume 2, Utility case assessments

    SciTech Connect (OSTI)

    Zaininger, H.W.; Ellis, P.R.; Schaefer, J.C. [Zaininger Engineering Co., San Jose, CA (United States)

    1994-06-01T23:59:59.000Z

    Electric utility distribution system impacts associated with the integration of renewable energy sources such as photovoltaics (PV) and wind turbines (WT) are considered in this project. The impacts are expected to vary from site to site according to the following characteristics: (1) The local solar insolation and/or wind characteristics; (2) renewable energy source penetration level; (3) whether battery or other energy storage systems are applied; and (4) local utility distribution design standards and planning practices. Small, distributed renewable energy sources are connected to the utility distribution system like other, similar kW- and MW-scale equipment and loads. Residential applications are expected to be connected to single-phase 120/240-V secondaries. Larger kw-scale applications may be connected to three-phase secondaries, and larger hundred-kW and MW-scale applications, such as MW-scale windfarms or PV plants, may be connected to electric utility primary systems via customer-owned primary and secondary collection systems. Small, distributed renewable energy sources installed on utility distribution systems will also produce nonsite-specific utility generation system benefits such as energy and capacity displacement benefits, in addition to the local site-specific distribution system benefits. Although generation system benefits are not site-specific, they are utility-specific, and they vary significantly among utilities in different regions. In addition, transmission system benefits, environmental benefits and other benefits may apply. These benefits also vary significantly among utilities and regions. Seven utility case studies considering PV, WT, and battery storage were conducted to identify a range of potential renewable energy source distribution system applications.

  20. Integrated Computing, Communication, and Distributed Control of Deregulated Electric Power Systems

    SciTech Connect (OSTI)

    Bajura, Richard; Feliachi, Ali

    2008-09-24T23:59:59.000Z

    Restructuring of the electricity market has affected all aspects of the power industry from generation to transmission, distribution, and consumption. Transmission circuits, in particular, are stressed often exceeding their stability limits because of the difficulty in building new transmission lines due to environmental concerns and financial risk. Deregulation has resulted in the need for tighter control strategies to maintain reliability even in the event of considerable structural changes, such as loss of a large generating unit or a transmission line, and changes in loading conditions due to the continuously varying power consumption. Our research efforts under the DOE EPSCoR Grant focused on Integrated Computing, Communication and Distributed Control of Deregulated Electric Power Systems. This research is applicable to operating and controlling modern electric energy systems. The controls developed by APERC provide for a more efficient, economical, reliable, and secure operation of these systems. Under this program, we developed distributed control algorithms suitable for large-scale geographically dispersed power systems and also economic tools to evaluate their effectiveness and impact on power markets. Progress was made in the development of distributed intelligent control agents for reliable and automated operation of integrated electric power systems. The methodologies employed combine information technology, control and communication, agent technology, and power systems engineering in the development of intelligent control agents for reliable and automated operation of integrated electric power systems. In the event of scheduled load changes or unforeseen disturbances, the power system is expected to minimize the effects and costs of disturbances and to maintain critical infrastructure operational.

  1. Integrating Renewable Energy into the Transmission and Distribution System of the U. S. Virgin Islands

    SciTech Connect (OSTI)

    Burman, K.; Olis, D.; Gevorgian, V.; Warren, A.; Butt, R.; Lilienthal, P.; Glassmire, J.

    2011-09-01T23:59:59.000Z

    This report focuses on the economic and technical feasibility of integrating renewable energy technologies into the U.S. Virgin Islands transmission and distribution systems. The report includes three main areas of analysis: 1) the economics of deploying utility-scale renewable energy technologies on St. Thomas/St. John and St. Croix; 2) potential sites for installing roof- and ground-mount PV systems and wind turbines and the impact renewable generation will have on the electrical subtransmission and distribution infrastructure, and 3) the feasibility of a 100- to 200-megawatt power interconnection of the Puerto Rico Electric Power Authority (PREPA), Virgin Islands Water and Power Authority (WAPA), and British Virgin Islands (BVI) grids via a submarine cable system.

  2. Integrating Renewable Energy into the Transmission and Distribution...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Integrating Renewable Energy into the Transmission and Distribution System of the U.S. Virgin Islands Integrating Renewable Energy into the Transmission and Distribution System of...

  3. Sandia National Laboratories: Distribution Grid Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Second Annual Electric Power Research InstituteSandia Photovoltaic Systems Symposium On April 15, 2014, in Concentrating Solar Power, Distribution Grid Integration, Energy,...

  4. The Development of a Smart Distribution Grid Testbed for Integrated Information Management Systems

    SciTech Connect (OSTI)

    Lu, Ning; Du, Pengwei; Paulson, Patrick R.; Greitzer, Frank L.; Guo, Xinxin; Hadley, Mark D.

    2011-07-28T23:59:59.000Z

    This paper presents a smart distribution grid testbed to test or compare designs of integrated information management systems (I2MSs). An I2MS extracts and synthesizes information from a wide range of data sources to detect abnormal system behaviors, identify possible causes, assess the system status, and provide grid operators with response suggestions. The objective of the testbed is to provide a modeling environment with sufficient data sources for the I2MS design. The testbed includes five information layers and a physical layer; it generates multi-layer chronological data based on actual measurement playbacks or simulated data sets produced by the physical layer. The testbed models random hardware failures, human errors, extreme weather events, and deliberate tampering attempts to allow users to evaluate the performance of different I2MS designs. Initial results of I2MS performance tests showed that the testbed created a close-to-real-world environment that allowed key performance metrics of the I2MS to be evaluated.

  5. Integrated Transmission and Distribution Control

    SciTech Connect (OSTI)

    Kalsi, Karanjit; Fuller, Jason C.; Tuffner, Francis K.; Lian, Jianming; Zhang, Wei; Marinovici, Laurentiu D.; Fisher, Andrew R.; Chassin, Forrest S.; Hauer, Matthew L.

    2013-01-16T23:59:59.000Z

    Distributed, generation, demand response, distributed storage, smart appliances, electric vehicles and renewable energy resources are expected to play a key part in the transformation of the American power system. Control, coordination and compensation of these smart grid assets are inherently interlinked. Advanced control strategies to warrant large-scale penetration of distributed smart grid assets do not currently exist. While many of the smart grid technologies proposed involve assets being deployed at the distribution level, most of the significant benefits accrue at the transmission level. The development of advanced smart grid simulation tools, such as GridLAB-D, has led to a dramatic improvement in the models of smart grid assets available for design and evaluation of smart grid technology. However, one of the main challenges to quantifying the benefits of smart grid assets at the transmission level is the lack of tools and framework for integrating transmission and distribution technologies into a single simulation environment. Furthermore, given the size and complexity of the distribution system, it is crucial to be able to represent the behavior of distributed smart grid assets using reduced-order controllable models and to analyze their impacts on the bulk power system in terms of stability and reliability. The objectives of the project were to: • Develop a simulation environment for integrating transmission and distribution control, • Construct reduced-order controllable models for smart grid assets at the distribution level, • Design and validate closed-loop control strategies for distributed smart grid assets, and • Demonstrate impact of integrating thousands of smart grid assets under closed-loop control demand response strategies on the transmission system. More specifically, GridLAB-D, a distribution system tool, and PowerWorld, a transmission planning tool, are integrated into a single simulation environment. The integrated environment allows the load flow interactions between the bulk power system and end-use loads to be explicitly modeled. Power system interactions are modeled down to time intervals as short as 1-second. Another practical issue is that the size and complexity of typical distribution systems makes direct integration with transmission models computationally intractable. Hence, the focus of the next main task is to develop reduced-order controllable models for some of the smart grid assets. In particular, HVAC units, which are a type of Thermostatically Controlled Loads (TCLs), are considered. The reduced-order modeling approach can be extended to other smart grid assets, like water heaters, PVs and PHEVs. Closed-loop control strategies are designed for a population of HVAC units under realistic conditions. The proposed load controller is fully responsive and achieves the control objective without sacrificing the end-use performance. Finally, using the T&D simulation platform, the benefits to the bulk power system are demonstrated by controlling smart grid assets under different demand response closed-loop control strategies.

  6. INTEGRATION OF ADAPTIVE FILE ASSIGNMENT INTO DISTRIBUTED SAFETY-CRITICAL SYSTEMS

    E-Print Network [OSTI]

    Wedde, Horst F.

    . In safety-critical systems (such as nuclear power plants, autonomous cooperation of robots in Outer Space-Critical / Safety-critical Systems, Functional/ Operational Integration 1. INTRODUCTION Safety-critical systems that are typically unpredictable, a very high amount of adaptability of system functions is demanded. safety

  7. GridBank: A Grid Accounting Services Architecture (GASA) for Distributed Systems Sharing and Integration

    E-Print Network [OSTI]

    Buyya, Rajkumar

    GridBank: A Grid Accounting Services Architecture (GASA) for Distributed Systems Sharing Australia Nedlands, Western Australia, 6009 barmouta@csse.uwa.edu.au Rajkumar Buyya Grid Computing and Distributed Systems (GRIDS) Lab Dept. of Computer Science and Software Engineering The University of Melbourne

  8. Distribution Integrity Management Plant (DIMP)

    SciTech Connect (OSTI)

    Gonzales, Jerome F. [Los Alamos National Laboratory

    2012-05-07T23:59:59.000Z

    This document is the distribution integrity management plan (Plan) for the Los Alamos National Laboratory (LANL) Natural Gas Distribution System. This Plan meets the requirements of 49 CFR Part 192, Subpart P Distribution Integrity Management Programs (DIMP) for the LANL Natural Gas Distribution System. This Plan was developed by reviewing records and interviewing LANL personnel. The records consist of the design, construction, operation and maintenance for the LANL Natural Gas Distribution System. The records system for the LANL Natural Gas Distribution System is limited, so the majority of information is based on the judgment of LANL employees; the maintenance crew, the Corrosion Specialist and the Utilities and Infrastructure (UI) Civil Team Leader. The records used in this report are: Pipeline and Hazardous Materials Safety Administration (PHMSA) 7100.1-1, Report of Main and Service Line Inspection, Natural Gas Leak Survey, Gas Leak Response Report, Gas Leak and Repair Report, and Pipe-to-Soil Recordings. The specific elements of knowledge of the infrastructure used to evaluate each threat and prioritize risks are listed in Sections 6 and 7, Threat Evaluation and Risk Prioritization respectively. This Plan addresses additional information needed and a method for gaining that data over time through normal activities. The processes used for the initial assessment of Threat Evaluation and Risk Prioritization are the methods found in the Simple, Handy Risk-based Integrity Management Plan (SHRIMP{trademark}) software package developed by the American Pipeline and Gas Agency (APGA) Security and Integrity Foundation (SIF). SHRIMP{trademark} uses an index model developed by the consultants and advisors of the SIF. Threat assessment is performed using questions developed by the Gas Piping Technology Company (GPTC) as modified and added to by the SHRIMP{trademark} advisors. This Plan is required to be reviewed every 5 years to be continually refined and improved. Records for all piping system installed after the effective date of this Plan will be captured and retained in the UI records documentation system. Primary Utility Asbuilts are maintained by Utilities Mapping (UMAP) and additional records are maintained on the N drive. Engineering Change Notices (ECNs) are stored on the N drive under configuration management and kept up by Utilities and Infrastructure Division Office (UI-DO). Records include, at a minimum, the location where new piping and appurtenances are installed and the material of which they are constructed.

  9. Abstract Microgrids are a new concept for future energy dis-tribution systems that enable renewable energy integration and

    E-Print Network [OSTI]

    Collins, Emmanuel

    1 Abstract ­ Microgrids are a new concept for future energy dis- tribution systems that enable renewable energy integration and improved energy management capability. Microgrids consist of multiple power quality and power distribution reliability, microgrids need to operate in both grid

  10. NREL: Energy Systems Integration - Energy Systems Integration...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Printable Version Energy Systems Integration Facility Newsroom The Energy Systems Integration Facility (ESIF) will be one of the only megawatt-scale test facilities in the United...

  11. Automated Energy Distribution and Reliability System: Validation Integration - Results of Future Architecture Implementation

    SciTech Connect (OSTI)

    Buche, D. L.

    2008-06-01T23:59:59.000Z

    This report describes Northern Indiana Public Service Co. project efforts to develop an automated energy distribution and reliability system. The purpose of this project was to implement a database-driven GIS solution that would manage all of the company's gas, electric, and landbase objects. This report is second in a series of reports detailing this effort.

  12. Distributed Integrated Scheduling in Automated Manufacturing Systems with Transient Machine Failures

    E-Print Network [OSTI]

    Wedde, Horst F.

    as for a larger variety of products. At the same time better adaptability of transportation planning, electronic negotiations 1. Introduction Distributed Computer Control for Just-in- Time Production and production flows. The Just-in-Time method has not yet been used in computer-controlled manufacturing systems

  13. Assessing business models arising from the integration of distributed energy systems in the Chilean electric power system

    E-Print Network [OSTI]

    Le Dantec, Jorge I. (Jorge Ignacio)

    2014-01-01T23:59:59.000Z

    Electric power systems are more than just networks of generation, transmission and distribution assets. They are socio-technical systems, involving regulation, markets and technology availability. Presently, the dynamic ...

  14. Addressing System Integration Issues Required for the Developmente of Distributed Wind-Hydrogen Energy Systems: Final Report

    SciTech Connect (OSTI)

    Mann, M.D; Salehfar, H.; Harrison, K.W.; Dale, N.; Biaku, C.; Peters, A.J.; Hernandez-Pacheco: E.

    2008-04-01T23:59:59.000Z

    Wind generated electricity is a variable resource. Hydrogen can be generated as an energy storage media, but is costly. Advancements in power electronics and system integration are needed to make a viable system. Therefore, the long-term goal of the efforts at the University of North Dakota is to merge wind energy, hydrogen production, and fuel cells to bring emission-free and reliable power to commercial viability. The primary goals include 1) expand system models as a tool to investigate integration and control issues, 2) examine long-term effects of wind-electrolysis performance from a systematic perspective, and 3) collaborate with NREL and industrial partners to design, integrate, and quantify system improvements by implementing a single power electronics package to interface wild AC to PEM stack DC requirements. This report summarizes the accomplishments made during this project.

  15. Sandia National Laboratories: Distribution Grid Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Distribution Grid Integration Recent Sandia Secure, Scalable Microgrid Advanced Controls Research Accomplishments On March 3, 2015, in Capabilities, Distribution Grid Integration,...

  16. 384 JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, VOL. 19, NO. 2, APRIL 2010 Monolithically Integrated Gas Distribution

    E-Print Network [OSTI]

    Wilamowski, Bogdan Maciej

    and are particularly useful for vehicle power, distributed generation, and portable electronic devices [1]. Fuel cells]. In this context, polymer-electrolyte-membrane (PEM) fuel cells [7] and direct methanol fuel cells [8], [9] have Gas Distribution Chamber for Silicon MEMS Fuel Cells Antonio Luque, Senior Member, IEEE, José M

  17. Optimal Design of Grid-Connected PEV Charging Systems With Integrated Distributed Resources

    E-Print Network [OSTI]

    Perreault, David J.

    The penetration of plug-in electric vehicles and renewable distributed generation is expected to increase over the next few decades. Large scale unregulated deployment of either technology can have a detrimental impact on ...

  18. Thermal Control & System Integration

    Broader source: Energy.gov [DOE]

    The thermal control and system integration activity focuses on issues such as the integration of motor and power control technologies and the development of advanced thermal control technologies....

  19. High Efficiency Integrated Space Conditioning, Water Heating and Air Distribution System for HUD-Code Manufactured Housing

    SciTech Connect (OSTI)

    Henry DeLima; Joe Akin; Joseph Pietsch

    2008-09-14T23:59:59.000Z

    Recognizing the need for new space conditioning and water heating systems for manufactured housing, DeLima Associates assembled a team to develop a space conditioning system that would enhance comfort conditions while also reducing energy usage at the systems level. The product, Comboflair® was defined as a result of a needs analysis of project sponsors and industry stakeholders. An integrated system would be developed that would combine a packaged airconditioning system with a small-duct, high-velocity air distribution system. In its basic configuration, the source for space heating would be a gas water heater. The complete system would be installed at the manufactured home factory and would require no site installation work at the homesite as is now required with conventional split-system air conditioners. Several prototypes were fabricated and tested before a field test unit was completed in October 2005. The Comboflair® system, complete with ductwork, was installed in a 1,984 square feet, double-wide manufactured home built by Palm Harbor Homes in Austin, TX. After the home was transported and installed at a Palm Harbor dealer lot in Austin, TX, a data acquisition system was installed for remote data collection. Over 60 parameters were continuously monitored and measurements were transmitted to a remote site every 15 minutes for performance analysis. The Comboflair® system was field tested from February 2006 until April 2007. The cooling system performed in accordance with the design specifications. The heating system initially could not provide the needed capacity at peak heating conditions until the water heater was replaced with a higher capacity standard water heater. All system comfort goals were then met. As a result of field testing, we have identified improvements to be made to specific components for incorporation into production models. The Comboflair® system will be manufactured by Unico, Inc. at their new production facility in St. Louis, MO. The product will be initially launched in the hot-humid climates of the southern U.S.

  20. Sandia National Laboratories: Distribution Grid Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Energy Supply Transformation Needed On February 20, 2013, in DETL, Distribution Grid Integration, Energy, Energy Assurance, Energy Surety, Grid Integration, Infrastructure...

  1. Sandia National Laboratories: Distribution Grid Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Its Phase 1 Operational Demonstration in Late January On April 5, 2013, in Distribution Grid Integration, Energy Assurance, Energy Assurance, Energy Surety, Grid Integration,...

  2. Smart Grid Demos Provide Guidance on Integrating DER and RES into the Distribution System with Consideration of Transmission Impacts, Market Signals, and Technologies

    SciTech Connect (OSTI)

    Kueck, John D [ORNL] [ORNL; Hamilton, Stephanie [Electric Power Research Institute (EPRI)] [Electric Power Research Institute (EPRI); Smith, Merrill [U.S. Department of Energy] [U.S. Department of Energy

    2010-01-01T23:59:59.000Z

    This paper describes the overall process for developing a planning criteria and deployment strategy for technology applications under the US Department of Energy (USDOE) and Electric Power Research Institute (EPRI) Smart Grid programs. These activities described provide an understanding of each demonstration and how they individually and as group further industry knowledge of Distributed Energy Resources (DER) and Renewable Energy Sources (RES) impact the grid and how the distribution grid can interact with DER and RES in smart ways. Both USDOE through its Renewable and Distributed Systems Integration (RDSI) and EPRI via its Smart Grid Demonstration Program both assess how DER and RES can be integrated and operated to lower the carbon footprint.

  3. Systems integration for global sustainability

    E-Print Network [OSTI]

    2015-01-01T23:59:59.000Z

    Le, A. Z. Khan, Improving integration for integrated coastal347 ISSUE 6225 Systems integration for global sustainabilitySUSTAINABILITY Systems integration for global sustainability

  4. Integrated Ice Storage/Sprinkler HVAC System Sharply Cuts Energy Costs and Air-Distribution First Costs

    E-Print Network [OSTI]

    Meckler, G.

    1986-01-01T23:59:59.000Z

    Integrated ice thermal storage/sprinkler HVAC systems developed and applied by the author in several commercial applications shift a major portion of electric utility demand to cheaper off-peak hours, while also reducing significantly the first cost...

  5. Microfluidic Systems Integrated Microfluidic Systems**

    E-Print Network [OSTI]

    Ismagilov, Rustem F.

    Microfluidic Systems Integrated Microfluidic Systems** Rustem F. Ismagilov* Keywords: analytical methods · enzymes · microfluidics · microreactors · protein structures Microfluidic systems use networks of channels thinner than a human hair to manipulate nanoliter volumes of re- agents. The goal of microfluidics

  6. Globally Integrated Power and Clock Distribution Network

    E-Print Network [OSTI]

    Friedman, Eby G.

    Globally Integrated Power and Clock Distribution Network Renatas Jakushokas and Eby G. Friedman and clock distribution networks are fundamentally different in terms of signal frequency and current flow signals may be integrated to eliminate the on-chip global clock distribution network. This combined

  7. Integration of Demand Side Management, Distributed Generation...

    Open Energy Info (EERE)

    integration of energy efficiency, distributed generation, renewable energy resources and energy storage technologies, both locally and globally, to maximize the value of the...

  8. Sandia National Laboratories: Distributed Grid Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Distributed Grid Integration Federal Electric Regulatory Commission Revised Its Small Generator Interconnection Procedure and Small Generator Interconnection Agreement On March 4,...

  9. Distributed Theorem Proving for Distributed Hybrid Systems

    E-Print Network [OSTI]

    Platzer, André

    system with a varying number of arbitrarily many cars. 1 Introduction Hybrid systems with joint discrete a multi-agent system, e.g., distributed car control systems. Such systems form distributed hybrid systemsDistributed Theorem Proving for Distributed Hybrid Systems David W. Renshaw, Sarah M. Loos

  10. Introduction to Distributed Systems

    E-Print Network [OSTI]

    Pous, Damien

    1 Introduction to Distributed Systems Fabienne Boyer, LIG, fabienne.boyer@inria.fr Sources: Cours d'Olivier Gruber, Sacha Krakowiak, Sara Bouchenak, UJF Fabienne Boyer, Distributed Programming 2 Objectives Study conceptual and practical aspects of distributed systems l Client-server model l Distributed protocols l

  11. Systems Integration (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2011-10-01T23:59:59.000Z

    The Systems Integration (SI) subprogram works closely with industry, universities, and the national laboratories to overcome technical barriers to the large-scale deployment of solar technologies. To support these goals, the subprogram invests primarily in four areas: grid integration, technology validation, solar resource assessment, and balance of system development.

  12. FRIB cryogenic distribution system

    SciTech Connect (OSTI)

    Ganni, V.; Dixon, K.; Laverdure, N.; Knudsen, P.; Arenius, D. [Thomas Jefferson National Accelerator Facility (JLab), Newport News, VA 23606 (United States); Barrios, M.; Jones, S.; Johnson, M.; Casagrande, F. [Facility for Rare Isotope Beams (FRIB), Michigan State University, East Lansing, MI 48824 (United States)

    2014-01-29T23:59:59.000Z

    The Michigan State University Facility for Rare Isotope Beams (MSU-FRIB) helium distribution system has been revised to include bayonet/warm valve type disconnects between each cryomodule and the transfer line distribution system, similar to the Thomas Jefferson National Accelerator Facility (JLab) and the Spallation Neutron Source (SNS) cryogenic distribution systems. The heat loads at various temperature levels and some of the features in the design of the distribution system are outlined. The present status, the plans for fabrication, and the procurement approach for the helium distribution system are also included.

  13. FRIB cryogenic distribution system

    SciTech Connect (OSTI)

    Ganni, Venkatarao [JLAB; Dixon, Kelly D. [JLAB; Laverdure, Nathaniel A. [JLAB; Knudsen, Peter N. [JLAB; Arenius, Dana M. [JLAB; Barrios, Matthew N. [Michigan State; Jones, S. [Michigan State; Johnson, M. [Michigan State; Casagrande, Fabio [Michigan State

    2014-01-01T23:59:59.000Z

    The Michigan State University Facility for Rare Isotope Beams (MSU-FRIB) helium distribution system has been revised to include bayonet/warm valve type disconnects between each cryomodule and the transfer line distribution system, similar to the Thomas Jefferson National Accelerator Facility (JLab) and the Spallation Neutron Source (SNS) cryogenic distribution systems. The heat loads at various temperature levels and some of the features in the design of the distribution system are outlined. The present status, the plans for fabrication, and the procurement approach for the helium distribution system are also included.

  14. SOLAR PROGRAM: SYSTEMS INTEGRATION

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2010 2. Current Request for Information (RFI) 3. Questions 4 | Systems Integration eere.energy.gov Summary of 1W Workshop Date: August 11th and 12th, 2010 Attendees: 86 total;...

  15. Power Systems Integration Laboratory (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2011-10-01T23:59:59.000Z

    This fact sheet describes the purpose, lab specifications, applications scenarios, and information on how to partner with NREL's Power Systems Integration Laboratory at the Energy Systems Integration Facility. At NREL's Power Systems Integration Laboratory in the Energy Systems Integration Facility (ESIF), research focuses on developing and testing large-scale distributed energy systems for grid-connected, stand-alone, and microgrid applications. The laboratory can accommodate large power system components such as inverters for photovoltaic (PV) and wind systems, diesel and natural gas generators, battery packs, microgrid interconnection switchgear, and vehicles. Closely coupled with the research electrical distribution bus at the ESIF, the Power Systems Integration Laboratory will offer power testing capability of megawatt-scale DC and AC power systems, as well as advanced hardware-in-the-loop and model-in-the-loop simulation capabilities. Thermal heating and cooling loops and fuel also allow testing of combined heating/cooling and power systems (CHP).

  16. Integrated, Automated Distributed Generation Technologies Demonstration

    SciTech Connect (OSTI)

    Jensen, Kevin

    2014-09-30T23:59:59.000Z

    The purpose of the NETL Project was to develop a diverse combination of distributed renewable generation technologies and controls and demonstrate how the renewable generation could help manage substation peak demand at the ATK Promontory plant site. The Promontory plant site is located in the northwestern Utah desert approximately 25 miles west of Brigham City, Utah. The plant encompasses 20,000 acres and has over 500 buildings. The ATK Promontory plant primarily manufactures solid propellant rocket motors for both commercial and government launch systems. The original project objectives focused on distributed generation; a 100 kW (kilowatt) wind turbine, a 100 kW new technology waste heat generation unit, a 500 kW energy storage system, and an intelligent system-wide automation system to monitor and control the renewable energy devices then release the stored energy during the peak demand time. The original goal was to reduce peak demand from the electrical utility company, Rocky Mountain Power (RMP), by 3.4%. For a period of time we also sought to integrate our energy storage requirements with a flywheel storage system (500 kW) proposed for the Promontory/RMP Substation. Ultimately the flywheel storage system could not meet our project timetable, so the storage requirement was switched to a battery storage system (300 kW.) A secondary objective was to design/install a bi-directional customer/utility gateway application for real-time visibility and communications between RMP, and ATK. This objective was not achieved because of technical issues with RMP, ATK Information Technology Department’s stringent requirements based on being a rocket motor manufacturing facility, and budget constraints. Of the original objectives, the following were achieved: • Installation of a 100 kW wind turbine. • Installation of a 300 kW battery storage system. • Integrated control system installed to offset electrical demand by releasing stored energy from renewable sources during peak hours of the day. Control system also monitors the wind turbine and battery storage system health, power output, and issues critical alarms. Of the original objectives, the following were not achieved: • 100 kW new technology waste heat generation unit. • Bi-directional customer/utility gateway for real time visibility and communications between RMP and ATK. • 3.4% reduction in peak demand. 1.7% reduction in peak demand was realized instead.

  17. Advanced Integrated Traction System

    SciTech Connect (OSTI)

    Greg Smith; Charles Gough

    2011-08-31T23:59:59.000Z

    The United States Department of Energy elaborates the compelling need for a commercialized competitively priced electric traction drive system to proliferate the acceptance of HEVs, PHEVs, and FCVs in the market. The desired end result is a technically and commercially verified integrated ETS (Electric Traction System) product design that can be manufactured and distributed through a broad network of competitive suppliers to all auto manufacturers. The objectives of this FCVT program are to develop advanced technologies for an integrated ETS capable of 55kW peak power for 18 seconds and 30kW of continuous power. Additionally, to accommodate a variety of automotive platforms the ETS design should be scalable to 120kW peak power for 18 seconds and 65kW of continuous power. The ETS (exclusive of the DC/DC Converter) is to cost no more than $660 (55kW at $12/kW) to produce in quantities of 100,000 units per year, should have a total weight less than 46kg, and have a volume less than 16 liters. The cost target for the optional Bi-Directional DC/DC Converter is $375. The goal is to achieve these targets with the use of engine coolant at a nominal temperature of 105C. The system efficiency should exceed 90% at 20% of rated torque over 10% to 100% of maximum speed. The nominal operating system voltage is to be 325V, with consideration for higher voltages. This project investigated a wide range of technologies, including ETS topologies, components, and interconnects. Each technology and its validity for automotive use were verified and then these technologies were integrated into a high temperature ETS design that would support a wide variety of applications (fuel cell, hybrids, electrics, and plug-ins). This ETS met all the DOE 2010 objectives of cost, weight, volume and efficiency, and the specific power and power density 2015 objectives. Additionally a bi-directional converter was developed that provides charging and electric power take-off which is the first step towards enabling a smart-grid application. GM under this work assessed 29 technologies; investigated 36 configurations/types power electronics and electric machines, filed 41 invention disclosures; and ensured technology compatibility with vehicle production. Besides the development of a high temperature ETS the development of industrial suppliers took place because of this project. Suppliers of industrial power electronic components are numerous, but there are few that have traction drive knowledge. This makes it difficult to achieve component reliability, durability, and cost requirements necessary of high volume automotive production. The commercialization of electric traction systems for automotive industry requires a strong diverse supplier base. Developing this supplier base is dependent on a close working relationship between the OEM and supplier so that appropriate component requirements can be developed. GM has worked closely with suppliers to develop components for electric traction systems. Components that have been the focus of this project are power modules, capacitors, heavy copper boards, current sensors, and gate drive and controller chip sets. Working with suppliers, detailed component specifications have been developed. Current, voltage, and operation environment during the vehicle drive cycle were evaluated to develop higher resolution/accurate component specifications.

  18. Integration in superspace using distribution theory

    E-Print Network [OSTI]

    K. Coulembier; H. De Bie; F. Sommen

    2009-09-14T23:59:59.000Z

    In this paper, a new class of Cauchy integral formulae in superspace is obtained, using formal expansions of distributions. This allows to solve five open problems in the study of harmonic and Clifford analysis in superspace.

  19. Sandia Energy - Distribution Grid Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiation Protection245C Unlimited ReleaseWelcomeLongEnergy StorageB.

  20. Sandia Energy - Distribution Grid Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiation Protection245C Unlimited ReleaseWelcomeLongEnergy StorageB.DETL Permalink

  1. Enhancing the Smart Grid: Integrating Clean Distributed and Renewable...

    Energy Savers [EERE]

    Enhancing the Smart Grid: Integrating Clean Distributed and Renewable Generation Enhancing the Smart Grid: Integrating Clean Distributed and Renewable Generation Imagine a grid...

  2. Cooling water distribution system

    DOE Patents [OSTI]

    Orr, Richard (Pittsburgh, PA)

    1994-01-01T23:59:59.000Z

    A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using an interconnected series of radial guide elements, a plurality of circumferential collector elements and collector boxes to collect and feed the cooling water into distribution channels extending along the curved surface of the steel containment vessel. The cooling water is uniformly distributed over the curved surface by a plurality of weirs in the distribution channels.

  3. Sandia Energy - Distribution Grid Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Scienceand RequirementsCoatings Initiated at PNNL's SequimReactors ToDecisionDistribution Grid

  4. Integrated Distribution Planning Concept Paper

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville PowerCherries 82981-1cnHigh SchoolIn Other NewsSpin andInterim Data Changes in the2011Distribution

  5. Modular Integrated Energy Systems

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    Building 3147 Oak Ridge, TN 37831 April 27, 2006 Prepared by: Honeywell Laboratories 3660 Technology Drive Honeywell #12;Modular Integrated Energy Systems Task 5 Prototype Development Reference Design Documentation: Steve Gabel, Program Manager (612) 951-7555 Honeywell Laboratories 3660 Technology Drive Minneapolis

  6. Modular Integrated Energy Systems

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    Building 3147 Oak Ridge, TN 37831 July 22, 2005 Prepared by: Honeywell Laboratories 3660 Technology Drive­April 2005 Honeywell #12;Modular Integrated Energy Systems Task 6 Field Monitoring Interim Report Period Oak Ridge, TN 37831 Prepared by: Steve Gabel, Program Manager (612) 951-7555 Honeywell Laboratories

  7. Modular Integrated Energy Systems

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    Building 3147 Oak Ridge, TN 37831 March 24, 2005 Prepared by: Honeywell Laboratories 3660 Technology Drive­December 2004 Honeywell #12;Modular Integrated Energy Systems Task 6 Field Monitoring Interim Report Period Oak Ridge, TN 37831 Prepared by: Steve Gabel, Program Manager (612) 951-7555 Honeywell Laboratories

  8. Modular Integrated Energy Systems

    E-Print Network [OSTI]

    Oak Ridge National Laboratory

    Honeywell Modular Integrated Energy Systems Task 6 Field Monitoring Interim Report Period Covered 3147 Oak Ridge, TN 37831 Prepared by: Honeywell Laboratories 3660 Technology Drive Minneapolis, MN 3147 Oak Ridge, TN 37831 Prepared by: Steve Gabel, Program Manager (612) 951-7555 Honeywell

  9. integration division Human Systems

    E-Print Network [OSTI]

    integration division Human Systems Eye-Movement Metrics: Non-Intrusive Quantitative Tools for Monitoring Human Visual Performance Objective Approach Impact A reliable quantitative yet non-intrusive methodologies that provide quantitative yet non-intrusive measures of human visual performance for use

  10. Lectures on integrable Hamiltonian systems

    E-Print Network [OSTI]

    G. Sardanashvily

    2013-03-21T23:59:59.000Z

    We consider integrable Hamiltonian systems in a general setting of invariant submanifolds which need not be compact. For instance, this is the case a global Kepler system, non-autonomous integrable Hamiltonian systems and integrable systems with time-dependent parameters.

  11. Integration of Distributed Energy The CERTS MicroGrid Concept

    E-Print Network [OSTI]

    Resources The MicroGrid Concept Appendices Prepared for Transmission Reliability Program Office of PowerIntegration of Distributed Energy Resources The CERTS MicroGrid Concept CALIFORNIA ENERGY;Preface The U.S. Electricity Grid Today The U.S. electric power system is in the midst of a fundamental

  12. NREL: Energy Systems Integration Facility - Systems Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit |Infrastructure The foundation of

  13. Twisted symmetries and integrable systems

    E-Print Network [OSTI]

    G. Cicogna; G. Gaeta

    2010-02-07T23:59:59.000Z

    Symmetry properties are at the basis of integrability. In recent years, it appeared that so called "twisted symmetries" are as effective as standard symmetries in many respects (integrating ODEs, finding special solutions to PDEs). Here we discuss how twisted symmetries can be used to detect integrability of Lagrangian systems which are not integrable via standard symmetries.

  14. Power Systems Integration Laboratory (Fact Sheet), NREL (National...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from fundamental research to applications engineering. Partners at the ESIF's Power Systems Integration Laboratory may include: * Manufacturers of distributed generation and...

  15. Distributed Optimization System

    DOE Patents [OSTI]

    Hurtado, John E. (Albuquerque, NM); Dohrmann, Clark R. (Albuquerque, NM); Robinett, III, Rush D. (Tijeras, NM)

    2004-11-30T23:59:59.000Z

    A search system and method for controlling multiple agents to optimize an objective using distributed sensing and cooperative control. The search agent can be one or more physical agents, such as a robot, and can be software agents for searching cyberspace. The objective can be: chemical sources, temperature sources, radiation sources, light sources, evaders, trespassers, explosive sources, time dependent sources, time independent sources, function surfaces, maximization points, minimization points, and optimal control of a system such as a communication system, an economy, a crane, and a multi-processor computer.

  16. Integrated Renewable Energy and Energy Storage Systems

    E-Print Network [OSTI]

    Integrated Renewable Energy and Energy Storage Systems Prepared for the U.S. Department of Energy and Energy Storage Systems TABLE OF CONTENTS 1 Office of Electricity Delivery and Energy Reliability Under Award No. DE-FC-06NT42847 Hawai`i Distributed

  17. Integrated Retail & Wholesale Power System Operation

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    Integrated Retail & Wholesale Power System Operation with Smart-Grid Functionality PIs: Dionysios Retail/Wholesale Power System Operation with Smart-Grid Functionality Project PIs: Dionysios Aliprantis (open-source release): AMES Wholesale Power Market Testbed (ISU) + GridLAB-D distribution platform (DOE

  18. On the integration of the Curriculum Initiative on Parallel and Distributed Computing in the Spanish university system

    E-Print Network [OSTI]

    Giménez, Domingo

    University of La Laguna, University of Murcia, University of Granada, Polytechnic University of Valencia Laguna Par Conc+Par Systems Program. First semester Second semester Third semester Fourth semester Fifth represent to what extent each topic is treated in common courses. Green means it is a core topic, yellow

  19. High-efficiency grid-connected photovoltaic module integrated converter system with high-speed communication interfaces for small-scale distribution power generation

    SciTech Connect (OSTI)

    Choi, Woo-Young; Lai, Jih-Sheng (Jason) [Future Energy Electronics Center, Department of Electrical and Computer Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA (United States)

    2010-04-15T23:59:59.000Z

    This paper presents a high-efficiency grid-connected photovoltaic (PV) module integrated converter (MIC) system with reduced PV current variation. The proposed PV MIC system consists of a high-efficiency step-up DC-DC converter and a single-phase full-bridge DC-AC inverter. An active-clamping flyback converter with a voltage-doubler rectifier is proposed for the step-up DC-DC converter. The proposed step-up DC-DC converter reduces the switching losses by eliminating the reverse-recovery current of the output rectifying diodes. To reduce the PV current variation introduced by the grid-connected inverter, a PV current variation reduction method is also suggested. The suggested PV current variation reduction method reduces the PV current variation without any additional components. Moreover, for centralized power control of distributed PV MIC systems, a PV power control scheme with both a central control level and a local control level is presented. The central PV power control level controls the whole power production by sending out reference power signals to each individual PV MIC system. The proposed step-up DC-DC converter achieves a high-efficiency of 97.5% at 260 W output power to generate the DC-link voltage of 350 V from the PV voltage of 36.1 V. The PV MIC system including the DC-DC converter and the DC-AC inverter achieves a high-efficiency of 95% with the PV current ripple less than 3% variation of the rated PV current. (author)

  20. Distributed computing systems programme

    SciTech Connect (OSTI)

    Duce, D.

    1984-01-01T23:59:59.000Z

    Publication of this volume coincides with the completion of the U.K. Science and Engineering Research Council's coordinated programme of research in Distributed Computing Systems (DCS) which ran from 1977 to 1984. The volume is based on presentations made at the programme's final conference. The first chapter explains the origins and history of DCS and gives an overview of the programme and its achievements. The remaining sixteen chapters review particular research themes (including imperative and declarative languages, and performance modelling), and describe particular research projects in technical areas including local area networks, design, development and analysis of concurrent systems, parallel algorithm design, functional programming and non-von Neumann computer architectures.

  1. a constructive heuristic for the integrated inventory-distribution ...

    E-Print Network [OSTI]

    T. F. Abdelmaguid

    2008-01-12T23:59:59.000Z

    Jan 12, 2008 ... Abstract: We study the integrated inventory distribution problem which is concerned with multiperiod inventory holding, backlogging, and ...

  2. Quality monitored distributed voting system

    DOE Patents [OSTI]

    Skogmo, D.

    1997-03-18T23:59:59.000Z

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system. 6 figs.

  3. Quality monitored distributed voting system

    DOE Patents [OSTI]

    Skogmo, David (Albuquerque, NM)

    1997-01-01T23:59:59.000Z

    A quality monitoring system can detect certain system faults and fraud attempts in a distributed voting system. The system uses decoy voters to cast predetermined check ballots. Absent check ballots can indicate system faults. Altered check ballots can indicate attempts at counterfeiting votes. The system can also cast check ballots at predetermined times to provide another check on the distributed voting system.

  4. Sensor Networks for Monitoring and Control of Water Distribution Systems

    E-Print Network [OSTI]

    Whittle, Andrew

    Water distribution systems present a significant challenge for structural monitoring. They comprise a complex network of pipelines buried underground that are relatively inaccessible. Maintaining the integrity of these ...

  5. Integrated Transportation System Design Optimization

    E-Print Network [OSTI]

    Integrated Transportation System Design Optimization by Christine Taylor B.S. Cornell University by . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Professor Jaime Peraire Chairman, Department Graduate Committee #12;2 #12;Integrated Transportation System Abstract Traditionally, the design of a transportation system has focused on either the vehicle design

  6. National Renewable Energy Laboratory's Energy Systems Integration...

    Energy Savers [EERE]

    National Renewable Energy Laboratory's Energy Systems Integration Facility Overview National Renewable Energy Laboratory's Energy Systems Integration Facility Overview This...

  7. Onsite Wastewater Treatment Systems: Spray Distribution System

    E-Print Network [OSTI]

    Lesikar, Bruce J.

    2008-10-23T23:59:59.000Z

    Spray distribution systems for wastewater are much like lawn sprinkler systems, in that they spray treated wastewater over the surface of a yard. This publication explains how spray distribution systems work, what their design requirements are...

  8. Distributed road assessment system

    DOE Patents [OSTI]

    Beer, N. Reginald; Paglieroni, David W

    2014-03-25T23:59:59.000Z

    A system that detects damage on or below the surface of a paved structure or pavement is provided. A distributed road assessment system includes road assessment pods and a road assessment server. Each road assessment pod includes a ground-penetrating radar antenna array and a detection system that detects road damage from the return signals as the vehicle on which the pod is mounted travels down a road. Each road assessment pod transmits to the road assessment server occurrence information describing each occurrence of road damage that is newly detected on a current scan of a road. The road assessment server maintains a road damage database of occurrence information describing the previously detected occurrences of road damage. After the road assessment server receives occurrence information for newly detected occurrences of road damage for a portion of a road, the road assessment server determines which newly detected occurrences correspond to which previously detected occurrences of road damage.

  9. Advanced Integrated Electric Traction System

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Integrated Electric Traction System Greg S. Smith Email: gregory.3.smith@gm.com Phone: (310) 257-3812 Organization: General Motors Team members: Ames Laboratory Arnold Magnetics...

  10. Integrated system checkout report

    SciTech Connect (OSTI)

    Not Available

    1991-08-14T23:59:59.000Z

    The planning and preparation phase of the Integrated Systems Checkout Program (ISCP) was conducted from October 1989 to July 1991. A copy of the ISCP, DOE-WIPP 90--002, is included in this report as an appendix. The final phase of the Checkout was conducted from July 10, 1991, to July 23, 1991. This phase exercised all the procedures and equipment required to receive, emplace, and retrieve contact handled transuranium (CH TRU) waste filled dry bins. In addition, abnormal events were introduced to simulate various equipment failures, loose surface radioactive contamination events, and personnel injury. This report provides a detailed summary of each days activities during this period. Qualification of personnel to safely conduct the tasks identified in the procedures and the abnormal events were verified by observers familiar with the Bin-Scale CH TRU Waste Test requirements. These observers were members of the staffs of Westinghouse WID Engineering, QA, Training, Health Physics, Safety, and SNL. Observers representing a number of DOE departments, the state of new Mexico, and the Defense Nuclear Facilities Safety Board observed those Checkout activities conducted during the period from July 17, 1991, to July 23, 1991. Observer comments described in this report are those obtained from the staff member observers. 1 figs., 1 tab.

  11. Standard Data Exchanges for Distribution System Management

    SciTech Connect (OSTI)

    Thomas E. McDermott

    2007-10-05T23:59:59.000Z

    Databases and software tools for electric power distribution systems have not been integrated, and this leads to extra costs and restrictions imposed on utilities and other stakeholders. For example, distributed resource integration studies and modern grid technology assessments are more difficult and costly. New vendors face high market entry barriers, because it’s necessary to interface with large and customized data systems at each potential utility customer. This project promotes data and software tool integration, through a set of data translators based on a common object model. The data translators are delivered as open-source software, using appropriate Web software technologies. The parties who benefit include electric utilities (and their ratepayers), researchers at government laboratories and universities, small software companies wishing to enter the electric utility market, and parties wishing to interconnect distributed generation to a utility system.

  12. Noncommutative integrable systems and quasideterminants

    SciTech Connect (OSTI)

    Hamanaka, Masashi [Department of Mathematics, Nagoya University, Chikusa-ku, Nagoya, 464-8602 (Japan)

    2010-03-08T23:59:59.000Z

    We discuss extension of soliton theories and integrable systems into noncommutative spaces. In the framework of noncommutative integrable hierarchy, we give infinite conserved quantities and exact soliton solutions for many noncommutative integrable equations, which are represented in terms of Strachan's products and quasi-determinants, respectively. We also present a relation to an noncommutative anti-self-dual Yang-Mills equation, and make comments on how 'integrability' should be considered in noncommutative spaces.

  13. Energy Systems Integration Facility Overview

    SciTech Connect (OSTI)

    Arvizu, Dan; Chistensen, Dana; Hannegan, Bryan; Garret, Bobi; Kroposki, Ben; Symko-Davies, Martha; Post, David; Hammond, Steve; Kutscher, Chuck; Wipke, Keith

    2014-02-28T23:59:59.000Z

    The U.S. Department of Energy's Energy Systems Integration Facility (ESIF) is located at the National Renewable Energy Laboratory is the right tool, at the right time... a first-of-its-kind facility that addresses the challenges of large-scale integration of clean energy technologies into the energy systems that power the nation.

  14. Energy Systems Integration Facility Overview

    ScienceCinema (OSTI)

    Arvizu, Dan; Chistensen, Dana; Hannegan, Bryan; Garret, Bobi; Kroposki, Ben; Symko-Davies, Martha; Post, David; Hammond, Steve; Kutscher, Chuck; Wipke, Keith

    2014-06-10T23:59:59.000Z

    The U.S. Department of Energy's Energy Systems Integration Facility (ESIF) is located at the National Renewable Energy Laboratory is the right tool, at the right time... a first-of-its-kind facility that addresses the challenges of large-scale integration of clean energy technologies into the energy systems that power the nation.

  15. Energy Systems Integration Laboratory (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2011-10-01T23:59:59.000Z

    This fact sheet describes the purpose, lab specifications, applications scenarios, and information on how to partner with NREL's Energy Systems Integration Laboratory at the Energy Systems Integration Facility. The Energy Systems Integration Laboratory at NREL's Energy Systems Integration Facility (ESIF) provides a flexible, renewable-ready platform for research, development, and testing of state-of-the-art hydrogen-based and other energy storage systems. The main focus of the laboratory is assessment of the technical readiness, performance characterization, and research to help industry move these systems towards optimal renewable-based production and efficient utilization of hydrogen. Research conducted in the Energy Systems Integration Laboratory will advance engineering knowledge and market deployment of hydrogen technologies to support a growing need for versatile distributed electricity generation, applications in microgrids, energy storage for renewables integration, and home and station-based hydrogen vehicle fueling. Research activities are targeted to improve the technical readiness of the following: (1) Low and high temperature electrolyzers, reformers and fuel cells; (2) Mechanical and electrochemical compression systems; (3) Hydrogen storage; (4) Hydrogen vehicle refueling; and (5) Internal combustion or turbine technology for electricity production. Examples of experiments include: (1) Close- and direct-coupling of renewable energy sources (PV and wind) to electrolyzers; (2) Performance and efficiency validation of electrolyzers, fuel cells, and compressors; (3) Reliability and durability tracking and prediction; (4) Equipment modeling and validation testing; (5) Internal combustion or turbine technology for electricity production; and (6) Safety and code compliance.

  16. INTEGRATING PHOTOVOLTAIC SYSTEMS

    E-Print Network [OSTI]

    Delaware, University of

    for Energy and Environmental Policy University of Delaware February 2006 #12;INTEGRATING PHOTOVOLTAIC Delmarva Power Delaware Energy Office University of Delaware Center for Energy and Environmental Policy..................................................................................................... 5 3.3.1 Delaware's Solar Resource

  17. Electric Grid State Estimators for Distribution Systems with Microgrids

    E-Print Network [OSTI]

    Gupta, Vijay

    46556 Emails: {jhuang6,vgupta2,huang}@nd.edu Abstract--In the development of smart grid, state] into the distribution systems of the power grid. Such integration complicates the operation of distribution systemsElectric Grid State Estimators for Distribution Systems with Microgrids Jing Huang, Vijay Gupta

  18. Shipboard condition based maintenance and integrated power system initiatives

    E-Print Network [OSTI]

    Barber, Darrin E. (Darrin Eugene)

    2011-01-01T23:59:59.000Z

    With the U.S. Navy's continued focus on developing and implementing a robust integrated power system aboard future combatants, there has been an ever increasing effort to guarantee an electrical distribution system that ...

  19. Architectural Concerns in Distributed and Mobile Collaborative Systems

    E-Print Network [OSTI]

    Dustdar, Schahram

    Architectural Concerns in Distributed and Mobile Collaborative Systems Schahram Dustdar Harald Gall Distributed Systems Group, Vienna University of Technology Argentinierstrasse 8/184-1 A-1040 Wien, Austria to integrate Workflow Management Systems (WfMS), Groupware Systems, and Busi- ness Process Modeling Systems

  20. Grid integrated distributed PV (GridPV).

    SciTech Connect (OSTI)

    Reno, Matthew J.; Coogan, Kyle [Georgia Institute of Technology, Atlanta, GA

    2013-08-01T23:59:59.000Z

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functions are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in the OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function in the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  1. Integrated Safety Management System Manual

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2006-11-01T23:59:59.000Z

    This manual provides requirements and guidance for DOE and contractors to ensure development and implementation of an effective Integrated Safety Management system that is periodically reviewed and continuously improved. Canceled by DOE O 450.2.

  2. Advancing Energy Systems through Integration

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Oil 30 ever-greenenergy.com Ever-Green Energy Integrated Energy System Questions? Ken Smith, President and CEO ken.smith@ever-greenenergy.com www.districtenergy.com...

  3. Distributed expert systems for nuclear reactor control

    SciTech Connect (OSTI)

    Otaduy, P.J.

    1992-12-01T23:59:59.000Z

    A network of distributed expert systems is the heart of a prototype supervisory control architecture developed at the Oak Ridge National Laboratory (ORNL) for an advanced multimodular reactor. Eight expert systems encode knowledge on signal acquisition, diagnostics, safeguards, and control strategies in a hybrid rule-based, multiprocessing and object-oriented distributed computing environment. An interactive simulation of a power block consisting of three reactors and one turbine provides a realistic, testbed for performance analysis of the integrated control system in real-time. Implementation details and representative reactor transients are discussed.

  4. Distributed expert systems for nuclear reactor control

    SciTech Connect (OSTI)

    Otaduy, P.J.

    1992-01-01T23:59:59.000Z

    A network of distributed expert systems is the heart of a prototype supervisory control architecture developed at the Oak Ridge National Laboratory (ORNL) for an advanced multimodular reactor. Eight expert systems encode knowledge on signal acquisition, diagnostics, safeguards, and control strategies in a hybrid rule-based, multiprocessing and object-oriented distributed computing environment. An interactive simulation of a power block consisting of three reactors and one turbine provides a realistic, testbed for performance analysis of the integrated control system in real-time. Implementation details and representative reactor transients are discussed.

  5. Optimal Solar PV Arrays Integration for Distributed Generation

    SciTech Connect (OSTI)

    Omitaomu, Olufemi A [ORNL; Li, Xueping [University of Tennessee, Knoxville (UTK)

    2012-01-01T23:59:59.000Z

    Solar photovoltaic (PV) systems hold great potential for distributed energy generation by installing PV panels on rooftops of residential and commercial buildings. Yet challenges arise along with the variability and non-dispatchability of the PV systems that affect the stability of the grid and the economics of the PV system. This paper investigates the integration of PV arrays for distributed generation applications by identifying a combination of buildings that will maximize solar energy output and minimize system variability. Particularly, we propose mean-variance optimization models to choose suitable rooftops for PV integration based on Markowitz mean-variance portfolio selection model. We further introduce quantity and cardinality constraints to result in a mixed integer quadratic programming problem. Case studies based on real data are presented. An efficient frontier is obtained for sample data that allows decision makers to choose a desired solar energy generation level with a comfortable variability tolerance level. Sensitivity analysis is conducted to show the tradeoffs between solar PV energy generation potential and variability.

  6. A prototype Distributed Audit System

    SciTech Connect (OSTI)

    Banning, D.L. [Sparta, Inc., El Segundo, CA (United States)

    1993-08-01T23:59:59.000Z

    Security auditing systems are used to detect and assess unauthorized or abusive system usage. Historically, security audits were confined to a single computer system. Recent work examines ways of extending auditing to include heterogeneous groups of computers (distributed system). This paper describes the design and prototype development of a Distributed Audit System (DAS) which was developed with funding received from Lawrence Livermore Laboratory and through the Master`s thesis effort performed by the author at California State University, Long Beach. The DAS is intended to provide collection, transfer, and control of audit data on distributed, heterogeneous hosts.

  7. Integrated Building Management System (IBMS)

    SciTech Connect (OSTI)

    Anita Lewis

    2012-07-01T23:59:59.000Z

    This project provides a combination of software and services that more easily and cost-effectively help to achieve optimized building performance and energy efficiency. Featuring an open-platform, cloud- hosted application suite and an intuitive user experience, this solution simplifies a traditionally very complex process by collecting data from disparate building systems and creating a single, integrated view of building and system performance. The Fault Detection and Diagnostics algorithms developed within the IBMS have been designed and tested as an integrated component of the control algorithms running the equipment being monitored. The algorithms identify the normal control behaviors of the equipment without interfering with the equipment control sequences. The algorithms also work without interfering with any cooperative control sequences operating between different pieces of equipment or building systems. In this manner the FDD algorithms create an integrated building management system.

  8. TREATMENT SYSTEMS AN INTEGRATED APPROACH

    E-Print Network [OSTI]

    Heal, Kate

    for on-site management and treatment of effluent and solid waste 3. Provide for surface water attenuationECOLOGICAL TREATMENT SYSTEMS AN INTEGRATED APPROACH TO THE TREATMENT OF WASTE AND WASTE WATER biological removal efficiencies in excess of 95% Treatment system averages 92% reduction in suspended solids

  9. INTEGRATED CONTROL OF NEXT GENERATION POWER SYSTEM

    SciTech Connect (OSTI)

    None

    2010-02-28T23:59:59.000Z

    Control methodologies provide the necessary data acquisition, analysis and corrective actions needed to maintain the state of an electric power system within acceptable operating limits. These methods are primarily software-based algorithms that are nonfunctional unless properly integrated with system data and the appropriate control devices. Components of the control of power systems today include protective relays, supervisory control and data acquisition (SCADA), distribution automation (DA), feeder automation, software agents, sensors, control devices and communications. Necessary corrective actions are still accomplished using large electromechanical devices such as vacuum, oil and gas-insulated breakers, capacitor banks, regulators, transformer tap changers, reclosers, generators, and more recently FACTS (flexible AC transmission system) devices. The recent evolution of multi-agent system (MAS) technologies has been reviewed and effort made to integrate MAS into next generation power systems. A MAS can be defined as ��a loosely-coupled network of problem solvers that work together to solve problems that are beyond their individual capabilities��. These problem solvers, often called agents, are autonomous and may be heterogeneous in nature. This project has shown that a MAS has significant advantages over a single, monolithic, centralized problem solver for next generation power systems. Various communication media are being used in the electric power system today, including copper, optical fiber and power line carrier (PLC) as well as wireless technologies. These technologies have enabled the deployment of substation automation (SA) at many facilities. Recently, carrier and wireless technologies have been developed and demonstrated on a pilot basis. Hence, efforts have been made by this project to penetrate these communication technologies as an infrastructure for next generation power systems. This project has thus pursued efforts to use specific MAS methods as well as pertinent communications protocols to imbed and assess such technologies in a real electric power distribution system, specifically the Circuit of the Future (CoF) developed by Southern California Edison (SCE). By modeling the behavior and communication for the components of a MAS, the operation and control of the power distribution circuit have been enhanced. The use of MAS to model and integrate a power distribution circuit offers a significantly different approach to the design of next generation power systems. For example, ways to control a power distribution circuit that includes a micro-grid while considering the impacts of thermal constraints, and integrating voltage control and renewable energy sources on the main power system have been pursued. Both computer simulations and laboratory testbeds have been used to demonstrate such technologies in electric power distribution systems. An economic assessment of MAS in electric power systems was also performed during this project. A report on the economic feasibility of MAS for electric power systems was prepared, and particularly discusses the feasibility of incorporating MAS in transmission and distribution (T&D) systems. Also, the commercial viability of deploying MAS in T&D systems has been assessed by developing an initial case study using utility input to estimate the benefits of deploying MAS. In summary, the MAS approach, which had previously been investigated with good success by APERC for naval shipboard applications, has now been applied with promising results for enhancing an electric power distribution circuit, such as the Circuit of the Future developed by Southern California Edison. The results for next generation power systems include better ability to reconfigure circuits, improve protection and enhance reliability.

  10. Submodule Integrated Distributed Maximum Power Point Tracking for Solar Photovoltaic Applications

    E-Print Network [OSTI]

    Pilawa-Podgurski, Robert C. N.

    This paper explores the benefits of distributed power electronics in solar photovoltaic applications through the use of submodule integrated maximum power point trackers (MPPT). We propose a system architecture that provides ...

  11. Utility Wind Integration Group Distributed Wind/Solar Interconnection Workshop

    Broader source: Energy.gov [DOE]

    This two-day workshop will answer your questions about interconnecting wind and solar plants and other distributed generation applications to electric distribution systems while providing insight...

  12. Tools for Continuously Evaluating Distributed System Qualities James H. Hill

    E-Print Network [OSTI]

    Schmidt, Douglas C.

    throughout the software lifecycle [9]. For ex- ample, test-driven development and continuous integration, and security) for distributed systems has historically occurred late in the software lifecycle. As a result the software lifecycle. Keywords. agile techniques, continuous system inte- gration, distributed systems

  13. Integrated Solar Thermochemical Reaction System

    Broader source: Energy.gov [DOE]

    This fact sheet describes an integrated solar thermochemical reaction system project awarded under the DOE's 2012 SunShot Concentrating Solar Power R&D award program. The team, led by the Pacific Northwest National Laboratory, is working to develop and demonstrate a high-performance solar thermochemical reaction system in an end-to-end demonstration that produces electricity. A highly efficient solar thermochemical reaction system would allow for 24-hour operation without the need for storage technology, and reductions in total system costs while providing a relatively low-risk deployment option for CSP systems.

  14. ESIF 2014 (Energy Systems Integration Facility) (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2015-01-01T23:59:59.000Z

    This report covers research highlights and achievements for the Energy Systems Integration Facility in 2014.

  15. Power Electronic Thermal System Performance and Integration ...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    -- Washington D.C. ape13bennion.pdf More Documents & Publications Power Electronic Thermal System Performance and Integration Integrated Power Module Cooling Vehicle...

  16. Distributed Energy Resources for Carbon Emissions Mitigation

    E-Print Network [OSTI]

    Firestone, Ryan; Marnay, Chris

    2008-01-01T23:59:59.000Z

    and Energy Reliability, Distribution System Integrationand Energy Reliability, Distribution System Integration

  17. Impact of SolarSmart Subdivisions on SMUD's Distribution System

    SciTech Connect (OSTI)

    McNutt, P.; Hambrick, J.; Keesee, M.; Brown, D.

    2009-07-01T23:59:59.000Z

    This study analyzes the distribution impacts of high penetrations of grid-integrated renewable energy systems, specifically photovoltaic (PV) equipped SolarSmart Homes found in the Anatolia III Residential Community.

  18. Constructing Reliable Distributed Communication Systems with CORBA

    E-Print Network [OSTI]

    Schmidt, Douglas C.

    Constructing Reliable Distributed Communication Systems with CORBA Silvano Maffeis Douglas C model to support reliable data- and process- oriented distributed systems that communicate through syn distributed object computing systems with CORBA. First, we examine the question of whether reliable applica

  19. Integrated nonthermal treatment system study

    SciTech Connect (OSTI)

    Biagi, C.; Bahar, D.; Teheranian, B.; Vetromile, J. [Morrison Knudsen Corp. (United States); Quapp, W.J. [Nuclear Metals (United States); Bechtold, T.; Brown, B.; Schwinkendorf, W. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States); Swartz, G. [Swartz and Associates (United States)

    1997-01-01T23:59:59.000Z

    This report presents the results of a study of nonthermal treatment technologies. The study consisted of a systematic assessment of five nonthermal treatment alternatives. The treatment alternatives consist of widely varying technologies for safely destroying the hazardous organic components, reducing the volume, and preparing for final disposal of the contact-handled mixed low-level waste (MLLW) currently stored in the US Department of Energy complex. The alternatives considered were innovative nonthermal treatments for organic liquids and sludges, process residue, soil and debris. Vacuum desorption or various washing approaches are considered for treatment of soil, residue and debris. Organic destruction methods include mediated electrochemical oxidation, catalytic wet oxidation, and acid digestion. Other methods studied included stabilization technologies and mercury separation of treatment residues. This study is a companion to the integrated thermal treatment study which examined 19 alternatives for thermal treatment of MLLW waste. The quantities and physical and chemical compositions of the input waste are based on the inventory database developed by the US Department of Energy. The Integrated Nonthermal Treatment Systems (INTS) systems were evaluated using the same waste input (2,927 pounds per hour) as the Integrated Thermal Treatment Systems (ITTS). 48 refs., 68 figs., 37 tabs.

  20. Sandia Energy » Distribution Grid Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's PossibleRadiationImplementingnpitche Home About npitche This author hasSandia Student Wins Best

  1. Integrating Biomedical Text Mining Services into a Distributed Workflow Environment

    E-Print Network [OSTI]

    Gaizauskas, Rob

    the workflow. While many scientific workflows primarily involve operations on struc- tured or numerical dataIntegrating Biomedical Text Mining Services into a Distributed Workflow Environment Rob Gaizauskas they are distributed, i.e., where some of the data or processing resources are remote from the scientist initiating

  2. Integration of Storage Devices into Power Systems

    E-Print Network [OSTI]

    Integration of Storage Devices into Power Systems with Renewable Energy Sources Final Project System #12;Integration of Storage Devices into Power Systems with Renewable Energy Sources Final Project report for the Power Systems Engineering Research Center (PSERC) research project titled "Integration

  3. Integrated Deployment and the Energy Systems Integration Facility: Workshop Proceedings

    SciTech Connect (OSTI)

    Kroposki, B.; Werner, M.; Spikes, A.; Komomua, C.

    2013-01-01T23:59:59.000Z

    This report summarizes the workshop entitled: Integrated Deployment and the Energy Systems Integration Facility. In anticipation of the opening of the ESIF, NREL held the workshop August 21-23, 2012 and invited participants from utilities, government, industry, and academia to discuss renewable integration challenges and discover new ways to meet them by taking advantage of the ESIF's capabilities.

  4. Measuring Advances in HVAC Distribution System Design

    E-Print Network [OSTI]

    Franconi, E.

    2011-01-01T23:59:59.000Z

    Gabel and Andresen, HVAC Secondary Toolkil. Atlanta: ASHRAE,P_02 Measuring Advances in HVAC Distribution System Designdesign and operation of the HVAC thermal distribution system

  5. Building America Webinar: Ductless Hydronic Distribution Systems...

    Energy Savers [EERE]

    Building America Webinar: Ductless Hydronic Distribution Systems Building America Webinar: Ductless Hydronic Distribution Systems This webinar was presented by research team...

  6. Air distribution effectiveness with stratified air distribution systems

    E-Print Network [OSTI]

    Chen, Qingyan "Yan"

    1 Air distribution effectiveness with stratified air distribution systems Kisup Lee* Zheng Jiang, Ph.D Qingyan Chen, Ph.D. Student Member ASHRAE Fellow ASHRAE ABSTRACT Stratified air distribution systems such as Traditional Displacement Ventilation (TDV) and Under- Floor Air Distribution (UFAD

  7. Distributed Power Electronics for PV Systems (Presentation)

    SciTech Connect (OSTI)

    Deline, C.

    2011-12-01T23:59:59.000Z

    An overview of the benefits and applications of microinverters and DC power optimizers in residential systems. Some conclusions from this report are: (1) The impact of shade is greater than just the area of shade; (2) Additional mismatch losses include panel orientation, panel distribution, inverter voltage window, soiling; (3) Per-module devices can help increase performance, 4-12% or more depending on the system; (4) Value-added benefits (safety, monitoring, reduced design constraints) are helping their adoption; and (5) The residential market is growing rapidly. Efficiency increases, cost reductions are improving market acceptance. Panel integration will further reduce price and installation cost. Reliability remains an unknown.

  8. Integration

    E-Print Network [OSTI]

    Koschorke, Albrecht; Musanovic, Emina

    2013-01-01T23:59:59.000Z

    Integration By Albrecht Koschorkeby Emina Musanovic [Integration (from Lat. integrare, “toa social unity. Social integration is distinct from systemic

  9. Cost estimation of human systems integration

    E-Print Network [OSTI]

    Liu, Kevin K. (Kevin Kaitan), 1986-

    2010-01-01T23:59:59.000Z

    Human Systems Integration (HSI) is the interdisciplinary technical and management processes for integrating human considerations within and across all system elements. The goal of this research is to develop a better ...

  10. Integrating Renewable Energy Systems in Buildings (Presentation)

    SciTech Connect (OSTI)

    Hayter, S. J.

    2011-08-01T23:59:59.000Z

    This presentation on integrating renewable energy systems into building was presented at the August, 2011 ASHRAE Region IX CRC meetings.

  11. Integrated risk information system (IRIS)

    SciTech Connect (OSTI)

    Tuxen, L. [Environmental Protection Agency, Washington, DC (United States)

    1990-12-31T23:59:59.000Z

    The Integrated Risk Information System (IRIS) is an electronic information system developed by the US Environmental Protection Agency (EPA) containing information related to health risk assessment. IRIS is the Agency`s primary vehicle for communication of chronic health hazard information that represents Agency consensus following comprehensive review by intra-Agency work groups. The original purpose for developing IRIS was to provide guidance to EPA personnel in making risk management decisions. This original purpose for developing IRIS was to guidance to EPA personnel in making risk management decisions. This role has expanded and evolved with wider access and use of the system. IRIS contains chemical-specific information in summary format for approximately 500 chemicals. IRIS is available to the general public on the National Library of Medicine`s Toxicology Data Network (TOXNET) and on diskettes through the National Technical Information Service (NTIS).

  12. Enhanced distributed energy resource system

    DOE Patents [OSTI]

    Atcitty, Stanley (Albuquerque, NM); Clark, Nancy H. (Corrales, NM); Boyes, John D. (Albuquerque, NM); Ranade, Satishkumar J. (Las Cruces, NM)

    2007-07-03T23:59:59.000Z

    A power transmission system including a direct current power source electrically connected to a conversion device for converting direct current into alternating current, a conversion device connected to a power distribution system through a junction, an energy storage device capable of producing direct current connected to a converter, where the converter, such as an insulated gate bipolar transistor, converts direct current from an energy storage device into alternating current and supplies the current to the junction and subsequently to the power distribution system. A microprocessor controller, connected to a sampling and feedback module and the converter, determines when the current load is higher than a set threshold value, requiring triggering of the converter to supply supplemental current to the power transmission system.

  13. Distributed vs. Centralized Power Systems Frequency Control

    E-Print Network [OSTI]

    Dimarogonas, Dimos

    Distributed vs. Centralized Power Systems Frequency Control Martin Andreasson12 , Dimos V control of electrical power systems. We propose a distributed controller which retains the reference class of large- scale systems are electrical power systems, which employ automatic generation control

  14. Integrated system for seismic evaluations

    SciTech Connect (OSTI)

    Xu, J.; Philippacopoulos, A.J.; Miller, C.A.; Costantino, C.J.; Graves, H.

    1989-01-01T23:59:59.000Z

    This paper describes the various features of the Seismic Module of the CARES system (Computer Analysis for Rapid Evaluation of Structures). This system was developed by Brookhaven National Laboratory (BNL) for the US Nuclear Regulatory Commission to perform rapid evaluations of structural behavior and capability of nuclear power plant facilities. The CARES is structured in a modular format. Each module performs a specific type of analysis i.e., static or dynamic, linear or nonlinear, etc. This paper describes the features of the Seismic Module in particular. The development of the Seismic Module of the CARES system is based on an approach which incorporates all major aspects of seismic analysis currently employed by the industry into an integrated system that allows for carrying out interactively computations of structural response to seismic motions. The code operates on a PC computer system and has multi-graphics capabilities. It has been designed with user friendly features and it allows for interactive manipulation of various analysis phases during the seismic design process. The capabilities of the seismic module include (a) generation of artificial time histories compatible with given design ground response spectra, (b) development of Power Spectral Density (PSD) functions associated with the seismic input, (c) deconvolution analysis using vertically propagating shear waves through a given soil profile, and (d) development of in-structure response spectra or corresponding PSD's. It should be pointed out that these types of analyses can also be performed individually by using available computer codes such as FLUSH, SAP, etc. The uniqueness of the CARES, however, lies on its ability to perform all required phases of the seismic analysis in an integrated manner. 5 refs., 6 figs.

  15. Integrated Vehicle Thermal Management Systems (VTMS) Analysis...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Systems (VTMS) AnalysisModeling Integrated Vehicle Thermal Management Systems (VTMS) AnalysisModeling 2009 DOE Hydrogen Program and Vehicle Technologies Program Annual Merit...

  16. Integrated control system and method

    DOE Patents [OSTI]

    Wang, Paul Sai Keat; Baldwin, Darryl; Kim, Myoungjin

    2013-10-29T23:59:59.000Z

    An integrated control system for use with an engine connected to a generator providing electrical power to a switchgear is disclosed. The engine receives gas produced by a gasifier. The control system includes an electronic controller associated with the gasifier, engine, generator, and switchgear. A gas flow sensor monitors a gas flow from the gasifier to the engine through an engine gas control valve and provides a gas flow signal to the electronic controller. A gas oversupply sensor monitors a gas oversupply from the gasifier and provides an oversupply signal indicative of gas not provided to the engine. A power output sensor monitors a power output of the switchgear and provide a power output signal. The electronic controller changes gas production of the gasifier and the power output rating of the switchgear based on the gas flow signal, the oversupply signal, and the power output signal.

  17. Dynamic Interactions of PV units in Low Volatge Distribution Systems

    E-Print Network [OSTI]

    Pota, Himanshu Roy

    Dynamic Interactions of PV units in Low Volatge Distribution Systems M. J. Hossain, J. Lu Griffith. Abstract--Photovoltaic (PV) units along with other distributed energy resources (DERs) are located close, robust control, stability. I. Introduction The integration level of PV units in low and medium voltage

  18. Distribution Grid Integration | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't Your Destiny:Revised Finding of No53197E T ADRAFTJanuary 2004 | DepartmentJanuaryVersionSystems

  19. Hot Water Distribution System Model Enhancements

    SciTech Connect (OSTI)

    Hoeschele, M.; Weitzel, E.

    2012-11-01T23:59:59.000Z

    This project involves enhancement of the HWSIM distribution system model to more accurately model pipe heat transfer. Recent laboratory testing efforts have indicated that the modeling of radiant heat transfer effects is needed to accurately characterize piping heat loss. An analytical methodology for integrating radiant heat transfer was implemented with HWSIM. Laboratory test data collected in another project was then used to validate the model for a variety of uninsulated and insulated pipe cases (copper, PEX, and CPVC). Results appear favorable, with typical deviations from lab results less than 8%.

  20. Non-Integrability of a weakly integrable Hamiltonian system

    E-Print Network [OSTI]

    Giuseppe Pucacco; Kjell Rosquist

    2003-08-29T23:59:59.000Z

    The geometric approach to mechanics based on the Jacobi metric allows to easily construct natural mechanical systems which are integrable (actually separable) at a fixed value of the energy. The aim of the present paper is to investigate the dynamics of a simple prototype system outside the zero-energy hypersurface. We find that the general situation is that in which integrability is not preserved at arbitrary values of the energy. The structure of the Hamiltonian in the separating coordinates at zero energy allows a perturbation treatment of this system at energies slightly different from zero, by which we obtain an analytical proof of non-integrability.

  1. A reliability assessment methodology for distribution systems with distributed generation

    E-Print Network [OSTI]

    Duttagupta, Suchismita Sujaya

    2006-08-16T23:59:59.000Z

    Reliability assessment is of primary importance in designing and planning distribution systems that operate in an economic manner with minimal interruption of customer loads. With the advances in renewable energy sources, Distributed Generation (DG...

  2. A Completely Integrated Approach to Developing, Implementing, Evaluating Distributed Active

    E-Print Network [OSTI]

    Wedde, Horst F.

    -critical systems, (such as nuclear power plants, distributed cooperation of autonomous robots in Outer Space a distributed testbed for database application systems in safety-critical real-time environments. Given that safety/ reliability requirements and real- time constraints are in conflict there cannot be a closed form

  3. Communication Systems for Grid Integration of Renewable Energy Resources

    E-Print Network [OSTI]

    Yu, F Richard; Xiao, Weidong; Choudhury, Paul

    2011-01-01T23:59:59.000Z

    There is growing interest in renewable energy around the world. Since most renewable sources are intermittent in nature, it is a challenging task to integrate renewable energy resources into the power grid infrastructure. In this grid integration, communication systems are crucial technologies, which enable the accommodation of distributed renewable energy generation and play extremely important role in monitoring, operating, and protecting both renewable energy generators and power systems. In this paper, we review some communication technologies available for grid integration of renewable energy resources. Then, we present the communication systems used in a real renewable energy project, Bear Mountain Wind Farm (BMW) in British Columbia, Canada. In addition, we present the communication systems used in Photovoltaic Power Systems (PPS). Finally, we outline some research challenges and possible solutions about the communication systems for grid integration of renewable energy resources.

  4. Integrating software architectures for distributed simulations and simulation analysis communities.

    SciTech Connect (OSTI)

    Goldsby, Michael E.; Fellig, Daniel; Linebarger, John Michael; Moore, Patrick Curtis; Sa, Timothy J.; Hawley, Marilyn F.

    2005-10-01T23:59:59.000Z

    The one-year Software Architecture LDRD (No.79819) was a cross-site effort between Sandia California and Sandia New Mexico. The purpose of this research was to further develop and demonstrate integrating software architecture frameworks for distributed simulation and distributed collaboration in the homeland security domain. The integrated frameworks were initially developed through the Weapons of Mass Destruction Decision Analysis Center (WMD-DAC), sited at SNL/CA, and the National Infrastructure Simulation & Analysis Center (NISAC), sited at SNL/NM. The primary deliverable was a demonstration of both a federation of distributed simulations and a federation of distributed collaborative simulation analysis communities in the context of the same integrated scenario, which was the release of smallpox in San Diego, California. To our knowledge this was the first time such a combination of federations under a single scenario has ever been demonstrated. A secondary deliverable was the creation of the standalone GroupMeld{trademark} collaboration client, which uses the GroupMeld{trademark} synchronous collaboration framework. In addition, a small pilot experiment that used both integrating frameworks allowed a greater range of crisis management options to be performed and evaluated than would have been possible without the use of the frameworks.

  5. Creating an Order in Distributed Digital Libraries by Integrating

    E-Print Network [OSTI]

    Rauber,Andreas

    Creating an Order in Distributed Digital Libraries by Integrating Independent Self­Organizing Maps/188, A--1040 Wien, Austria fandi, dieterg@ifs.tuwien.ac.at Abstract Digital document libraries information. In this paper we describe an approach for organizing dis­ tributed digital libraries based

  6. Distribution System Voltage Regulation by Distributed Energy Resources

    SciTech Connect (OSTI)

    Ceylan, Oguzhan [ORNL; Liu, Guodong [ORNL; Xu, Yan [ORNL; Tomsovic, Kevin [University of Tennessee, Knoxville (UTK)

    2014-01-01T23:59:59.000Z

    This paper proposes a control method to regulate voltages in 3 phase unbalanced electrical distribution systems. A constrained optimization problem to minimize voltage deviations and maximize distributed energy resource (DER) active power output is solved by harmony search algorithm. IEEE 13 Bus Distribution Test System was modified to test three different cases: a) only voltage regulator controlled system b) only DER controlled system and c) both voltage regulator and DER controlled system. The simulation results show that systems with both voltage regulators and DER control provide better voltage profile.

  7. Impact of Utility-Scale Distributed Wind on Transmission-Level System Operations

    SciTech Connect (OSTI)

    Brancucci Martinez-Anido, C.; Hodge, B. M.

    2014-09-01T23:59:59.000Z

    This report presents a new renewable integration study that aims to assess the potential for adding distributed wind to the current power system with minimal or no upgrades to the distribution or transmission electricity systems. It investigates the impacts of integrating large amounts of utility-scale distributed wind power on bulk system operations by performing a case study on the power system of the Independent System Operator-New England (ISO-NE).

  8. System/Building Tech Integration | Clean Energy | ORNL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SystemBuilding Integration SHARE System Building Technologies Integration The buildings industry encompasses numerous designers, builders, construction materials and components...

  9. Integration of Nontraditional Isotopic Systems Into Reaction...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Water-Rock Interaction, and Impacts of Water Chemistry on Reservoir Sustainability Integration of Nontraditional Isotopic Systems Into Reaction-Transport Models of EGS For...

  10. NREL: Energy Systems Integration Home Page

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Systems Integration News to learn what's happening in ESI at NREL and beyond. Photo of solar panels with the words 'Redefining What's Possible for Renewable Energy: Grid...

  11. Sandia National Laboratories: Energy Systems Integration Facility

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Energy Systems Integration Facility Widespread Hydrogen Fueling Infrastructure Is the Goal of H2FIRST Project On June 4, 2014, in Capabilities, Center for Infrastructure Research...

  12. Integrated Chemical Geothermometry System for Geothermal Exploration

    Broader source: Energy.gov [DOE]

    DOE Geothermal Peer Review 2010 - Presentation. Develop practical and reliable system to predict geothermal reservoir temperatures from integrated chemical analyses of spring and well fluids.

  13. Workshop: Systems Integration Vision Challenges and Opportunities...

    Broader source: Energy.gov (indexed) [DOE]

    after achieving the SunShot Initiative's cost targets for solar energy, successful systems integration will remain as the key barrier to enable significantly higher levels of...

  14. FUSION IGNITION RESEARCH EXPERIMENT SYSTEM INTEGRATION *

    E-Print Network [OSTI]

    FUSION IGNITION RESEARCH EXPERIMENT SYSTEM INTEGRATION * T. Brown Princeton Plasma Physics-- This paper describes the current status of the FIRE configuration and the integration of the major subsystem vessel integrates cooling and shielding in a shape that maximizes shielding of ex-vessel components

  15. FUSION IGNITION RESEARCH EXPERIMENT SYSTEM INTEGRATION *

    E-Print Network [OSTI]

    FUSION IGNITION RESEARCH EXPERIMENT SYSTEM INTEGRATION * T. Brown Princeton Plasma Physics of the FIRE configuration and the integration of the major subsystem components. FIRE has a major by a thermal enclosure. The double wall vacuum vessel integrates cooling and shielding in a shape

  16. Integrated Project Management System description

    SciTech Connect (OSTI)

    NONE

    1994-09-01T23:59:59.000Z

    The Integrated Program Management System (IPMS) Description is a ``working`` document that describes the work processes of the Uranium Mill Tailings Remedial Action Project Office (UMTRA) and IPMS Group. This document has undergone many revisions since the UMTRA Project began; this revision not only updates the work processes but more clearly explains the relationships between the Project Office, contractors, and other participants. The work process flow style has been revised to better describe Project work and the relationships of participants. For each work process, more background and guidance on ``why`` and ``what is expected`` is given. For example, a description of activity data sheets has been added in the work organization and the Project performance and reporting processes, as well as additional detail about the federal budget process and funding management and improved flow charts and explanations of cost and schedule management. A chapter has been added describing the Cost Reduction/Productivity Improvement Program. The Change Control Board (CCB) procedures (Appendix A) have been updated. Project critical issues meeting (PCIM) procedures have been added as Appendix B. Budget risk assessment meeting procedures have been added as Appendix C. These appendices are written to act as stand-alone documentation for each process. As the procedures are improved and updated, the documentation can be updated separately.

  17. Reliable Distributed Computing for Decision Support Systems

    E-Print Network [OSTI]

    Bargiela, Andrzej

    Reliable Distributed Computing for Decision Support Systems Taha Osman, Andrzej Bargiela Department of application tasks on the currently avail- able computing nodes. Distributed Systems Reliability Due decision-support systems such as water distribution net- works, involving hundreds or even thousands

  18. Integration of Distributed Energy The CERTS MicroGrid Concept

    E-Print Network [OSTI]

    the California Energy Commission passed upon the accuracy or adequacy of the information in this report. #12 Foundation's Power Systems Engineering Research Center, and Sandia National Laboratories. #12;LBNL-50829 Systems Integration Program Public Interest Energy Research California Energy Commission Prepared

  19. Implementation Guide for Integrating Environmental Management Systems into Integrated Safety Management Systems

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2004-08-20T23:59:59.000Z

    This Guide provides guidance to assist DOE sites in identifying those missing environmental management systems elements and integrating them into the site's integrated safety management system. Canceled by DOE N 251.96.

  20. Power-Supply-Network Design in 3D Integrated Systems

    E-Print Network [OSTI]

    Lim, Sung Kyu

    Power-Supply-Network Design in 3D Integrated Systems Michael B. Healy and Sung Kyu Lim School power-supply noise in a layout- level 3D design prototype, and the impact of possible 3D-specific changes to the power-supply network design and topology. Our results show that distributing power-supply

  1. Integrated Planning for Water and Energy Systems

    E-Print Network [OSTI]

    Keller, Arturo A.

    of water in a specific location. #12;Water Extraction & Conveyance Water Treatment End-Use AgriculturalIntegrated Planning for Water and Energy Systems Integrated Planning for Water and Energy Systems Wilkinson, Ph.D. Director, Water Policy Program Bren School of Environmental Science and Management

  2. Advanced Integrated Systems Technology Development

    E-Print Network [OSTI]

    2013-01-01T23:59:59.000Z

    prototype personal comfort system devices, (5) a buildingprototype personal comfort system devices, (5) a buildingparts. Each personal comfort system device creates normal

  3. NREL: Energy Systems Integration - Solectria

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid Integration NREL is spearheading engineering

  4. NREL: Energy Systems Integration - Webmaster

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid Integration NREL is spearheading engineeringWebmaster Please

  5. Distributed Termination Detection for Dynamic Systems

    E-Print Network [OSTI]

    Dhamdhere, Dhananjay Madhav

    Distributed Termination Detection for Dynamic Systems D. M. Dhamdhere \\Lambda Sridhar R. Iyer E for detecting the termination of a dis­ tributed computation is presented. The algorithm does not require global are provided. Keywords Distributed algorithms, Distributed computation, Distributed termination, Dynamic

  6. Integrated transportation system design optimization

    E-Print Network [OSTI]

    Taylor, Christine P. (Christine Pia), 1979-

    2007-01-01T23:59:59.000Z

    Traditionally, the design of a transportation system has focused on either the vehicle design or the network flow, assuming the other as given. However, to define a system level architecture for a transportation system, ...

  7. Photovoltaic Systems Interconnected onto Network Distribution Systems--Success Stories

    SciTech Connect (OSTI)

    Coddington, M.; Kroposki, B.; Basso, T.; Lynn, K.; Sammon, D.; Vaziri, M.; Yohn, T.

    2009-04-01T23:59:59.000Z

    This report examines six case studies of photovoltaic systems integrated into secondary network systems in four major U.S. Solar America cities.

  8. Integrated Energy System Dispatch Optimization

    E-Print Network [OSTI]

    Firestone, Ryan; Stadler, Michael; Marnay, Chris

    2006-01-01T23:59:59.000Z

    Energy System Dispatch Optimization Ryan Firestone, MichaelEnergy System Dispatch Optimization Ryan Firestone - Studentthe real-time dispatch optimization problem for a generic

  9. AGIS: Evolution of Distributed Computing Information system for ATLAS

    E-Print Network [OSTI]

    Anisenkov, Alexey; The ATLAS collaboration; Alandes Pradillo, Maria; Karavakis, Edward

    2015-01-01T23:59:59.000Z

    The variety of the ATLAS Computing Infrastructure requires a central information system to define the topology of computing resources and to store the different parameters and configuration data which are needed by the various ATLAS software components. The ATLAS Grid Information System is the system designed to integrate configuration and status information about resources, services and topology of the computing infrastructure used by ATLAS Distributed Computing applications and services.

  10. NREL: Sustainable NREL - Energy Systems Integration Facility

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid Integration NRELCost of6DataEnergy Systems Integration

  11. Runtime Monitoring of Distributed Systems Adrian Francalanza

    E-Print Network [OSTI]

    Pace, Gordon J.

    As systems become more complex, monolithic architec- tures are becoming less common, and distributed-based and service-oriented systems readily fit in the above architecture, as do systems adhering to the Enterpris

  12. Runtime Monitoring of Distributed Systems Adrian Francalanza

    E-Print Network [OSTI]

    Francalanza, Adrian

    As systems become more complex, monolithic architec- tures are becoming less common, and distributed-based and service-oriented systems readily fit in the above architecture, as do systems adhering to the Enterprise

  13. A reliability assessment methodology for distribution systems with distributed generation 

    E-Print Network [OSTI]

    Duttagupta, Suchismita Sujaya

    2006-08-16T23:59:59.000Z

    Reliability assessment is of primary importance in designing and planning distribution systems that operate in an economic manner with minimal interruption of customer loads. With the advances in renewable energy sources, ...

  14. Photovoltaic Systems Interconnected onto Secondary Network Distribution Systems – Success Stories

    Broader source: Energy.gov [DOE]

    This report examines six case studies of photovoltaic (PV) systems integrated into secondary network systems. The six PV systems were chosen for evaluation because they are interconnected to secondary network systems located in four major Solar America Cities.

  15. Abstract--The issue of controlled and reliable integration of distributed energy resources into microgrids and large power

    E-Print Network [OSTI]

    Cańizares, Claudio A.

    resources (DER), many of them based on renewable energies, have experimented an unprecedented growth of the renewable energy sources, and its integration into power systems. One of the main technical issues1 Abstract-- The issue of controlled and reliable integration of distributed energy resources

  16. Systems Integration | ornl.gov

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over Our InstagramStructureProposed Action(InsertAbout the

  17. WATER DISTRIBUTION SYSTEM OPERATION: APPLICATION OF

    E-Print Network [OSTI]

    Mays, Larry W.

    CHAPTER 5 WATER DISTRIBUTION SYSTEM OPERATION: APPLICATION OF SIMULATED ANNEALING Fred E. Goldman Arizona State University, Tempe, Arizona 5.1 INTRODUCTION The operation of water distribution systems affects the water quality in these systems. EPA regulations require that water quality be maintained

  18. Prognostics for the Maintenance of Distributed Systems

    E-Print Network [OSTI]

    Pencolé, Yannick

    but also higher level function prognosis. I. INTRODUCTION In the classical case, preventive maintenance of preventive maintenance for complex systems. In this sense, a distributed system can be split down into a setPrognostics for the Maintenance of Distributed Systems Pauline Ribot, Yannick Pencol´e and Michel

  19. Low jitter RF distribution system

    DOE Patents [OSTI]

    Wilcox, Russell; Doolittle, Lawrence; Huang, Gang

    2012-09-18T23:59:59.000Z

    A timing signal distribution system includes an optical frequency stabilized laser signal amplitude modulated at an rf frequency. A transmitter box transmits a first portion of the laser signal and receive a modified optical signal, and outputs a second portion of the laser signal and a portion of the modified optical signal. A first optical fiber carries the first laser signal portion and the modified optical signal, and a second optical fiber carries the second portion of the laser signal and the returned modified optical signal. A receiver box receives the first laser signal portion, shifts the frequency of the first laser signal portion outputs the modified optical signal, and outputs an electrical signal on the basis of the laser signal. A detector at the end of the second optical fiber outputs a signal based on the modified optical signal. An optical delay sensing circuit outputs a data signal based on the detected modified optical signal. An rf phase detect and correct signal circuit outputs a signal corresponding to a phase stabilized rf signal based on the data signal and the frequency received from the receiver box.

  20. Integrated Brush Management Systems for Texas

    E-Print Network [OSTI]

    Hanselka, C. Wayne; Hamilton, Wayne T.; Rector, Barron S.

    2001-01-04T23:59:59.000Z

    Integrated Brush Management Systems (IBMS) involve careful analysis of range resources and ranch goals in order to develop solutions to brush problems. Successful use of IBMS should result in improved management processes and greater profitability...

  1. ITP Industrial Distributed Energy: Integrated Energy Systems...

    Broader source: Energy.gov (indexed) [DOE]

    increase the total market potential. To date, most IES is concentrated in education and health care buildings. The education sector includes universities, which have long used...

  2. Renewable and Distributed Systems Integration Peer Review

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn April 23, 2014, an OHASeptember 2010InJanuaryGeothermalRenewableSolar ThermalAn RPS is4

  3. Integrating GIS with Distributed Applications Using Dynamic Data-Sharing Mechanisms

    SciTech Connect (OSTI)

    Burnett, Robert A. (BATTELLE (PACIFIC NW LAB)); Tzemos, Spyridon (BATTELLE (PACIFIC NW LAB)); Stoops, LaMar R. (BATTELLE (PACIFIC NW LAB))

    2002-08-21T23:59:59.000Z

    Effective integration of a stand-alone GIS (e.g., ArcView 3.x) into a complex distributed software application requires an efficient, reliable mechanism for passing data and function requests to and from the GIS component. This paper describes the use of dynamic data-sharing and inter-process communication mechanisms to integrate GIS capability into a multi-jurisdictional distributed emergency management information system. These mechanisms include dynamic layer updates from spatial and attribute information shared via a distributed relational database across multiple sites; storage of private and shared ViewMarks to facilitate consistent GIS views; and asynchronous inter-process communication using function queuing and a data sharing library.

  4. Vehicle Systems Integration Laboratory Accelerates Powertrain Development

    SciTech Connect (OSTI)

    None

    2014-04-15T23:59:59.000Z

    ORNL's Vehicle Systems Integration (VSI) Laboratory accelerates the pace of powertrain development by performing prototype research and characterization of advanced systems and hardware components. The VSI Lab is capable of accommodating a range of platforms from advanced light-duty vehicles to hybridized Class 8 powertrains with the goals of improving overall system efficiency and reducing emissions.

  5. Vehicle Systems Integration Laboratory Accelerates Powertrain Development

    ScienceCinema (OSTI)

    None

    2014-06-25T23:59:59.000Z

    ORNL's Vehicle Systems Integration (VSI) Laboratory accelerates the pace of powertrain development by performing prototype research and characterization of advanced systems and hardware components. The VSI Lab is capable of accommodating a range of platforms from advanced light-duty vehicles to hybridized Class 8 powertrains with the goals of improving overall system efficiency and reducing emissions.

  6. Building a Smarter Distribution System in Pennsylvania

    Office of Environmental Management (EM)

    Development of an advanced distribution management system (DMS) software is at the heart of the project. The DMS monitors and controls all of the smart devices being installed...

  7. Coal Integrated Gasification Fuel Cell System Study

    SciTech Connect (OSTI)

    Chellappa Balan; Debashis Dey; Sukru-Alper Eker; Max Peter; Pavel Sokolov; Greg Wotzak

    2004-01-31T23:59:59.000Z

    This study analyzes the performance and economics of power generation systems based on Solid Oxide Fuel Cell (SOFC) technology and fueled by gasified coal. System concepts that integrate a coal gasifier with a SOFC, a gas turbine, and a steam turbine were developed and analyzed for plant sizes in excess of 200 MW. Two alternative integration configurations were selected with projected system efficiency of over 53% on a HHV basis, or about 10 percentage points higher than that of the state-of-the-art Integrated Gasification Combined Cycle (IGCC) systems. The initial cost of both selected configurations was found to be comparable with the IGCC system costs at approximately $1700/kW. An absorption-based CO2 isolation scheme was developed, and its penalty on the system performance and cost was estimated to be less approximately 2.7% and $370/kW. Technology gaps and required engineering development efforts were identified and evaluated.

  8. innovati nInterconnection Standards Guide Integration of Distributed

    E-Print Network [OSTI]

    the United States, energy circles are buzzing about the promise of the smart grid--the digital electric power), the concept is exciting, but it isn't new. Researchers here have been laying the foundation for the smart grid and storage sources (or"distributed resources,"a key aspect of the smart grid) into the electric power system

  9. Energy Systems Integration: A Convergence of Ideas

    SciTech Connect (OSTI)

    Kroposki, B.; Garrett, B.; MacMillan, S.; Rice, B.; Komomua, C.; O'Malley, M.; Zimmerle, D.

    2012-07-01T23:59:59.000Z

    Energy systems integration (ESI) enables the effective analysis, design, and control of these interactions and interdependencies along technical, economic, regulatory, and social dimensions. By focusing on the optimization of energy from all systems, across all pathways, and at all scales, we can better understand and make use of the co-benefits that result to increase reliability and performance, reduce cost, and minimize environmental impacts. This white paper discusses systems integration and the research in new control architectures that are optimized at smaller scales but can be aggregated to optimize energy systems at any scale and would allow replicable energy solutions across boundaries of existing and new energy pathways.

  10. NREL: Energy Systems Integration - Wyle

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Wyle Photo of a glass cube containing power electronics equipment in a laboratory Prototype CUBE system at the ESIF PSIL. Photo by Dennis Schroeder, NREL Under a research agreement...

  11. Systems Integration | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data CenterEnergyGlossaryProgramRussiaSpaceNewsSustainableSystemsSystems

  12. Lighting system with heat distribution face plate

    DOE Patents [OSTI]

    Arik, Mehmet; Weaver, Stanton Earl; Stecher, Thomas Elliot; Kuenzler, Glenn Howard; Wolfe, Jr., Charles Franklin; Li, Ri

    2013-09-10T23:59:59.000Z

    Lighting systems having a light source and a thermal management system are provided. The thermal management system includes synthetic jet devices, a heat sink and a heat distribution face plate. The synthetic jet devices are arranged in parallel to one and other and are configured to actively cool the lighting system. The heat distribution face plate is configured to radially transfer heat from the light source into the ambient air.

  13. Hybrid solar lighting distribution systems and components

    DOE Patents [OSTI]

    Muhs, Jeffrey D. (Lenoir City, TN); Earl, Dennis D. (Knoxville, TN); Beshears, David L. (Knoxville, TN); Maxey, Lonnie C. (Powell, TN); Jordan, John K. (Oak Ridge, TN); Lind, Randall F. (Lenoir City, TN)

    2011-07-05T23:59:59.000Z

    A hybrid solar lighting distribution system and components having at least one hybrid solar concentrator, at least one fiber receiver, at least one hybrid luminaire, and a light distribution system operably connected to each hybrid solar concentrator and each hybrid luminaire. A controller operates all components.

  14. VAXclusters: A Closely-Coupled Distributed System

    E-Print Network [OSTI]

    Anderson, Richard

    of VAX computers that operate as a single system. To achieve performance in a multicomputer environment designed. The software is a distributed version of the VAX/VMS operating system that uses a distributed efficient, for example, capable of sending and receiving 3000 messages per second on a VAX-11

  15. Coal Integrated Gasification Fuel Cell System Study

    SciTech Connect (OSTI)

    Gregory Wotzak; Chellappa Balan; Faress Rahman; Nguyen Minh

    2003-08-01T23:59:59.000Z

    The pre-baseline configuration for an Integrated Gasification Fuel Cell (IGFC) system has been developed. This case uses current gasification, clean-up, gas turbine, and bottoming cycle technologies together with projected large planar Solid Oxide Fuel Cell (SOFC) technology. This pre-baseline case will be used as a basis for identifying the critical factors impacting system performance and the major technical challenges in implementing such systems. Top-level system requirements were used as the criteria to evaluate and down select alternative sub-systems. The top choice subsystems were subsequently integrated to form the pre-baseline case. The down-selected pre-baseline case includes a British Gas Lurgi (BGL) gasification and cleanup sub-system integrated with a GE Power Systems 6FA+e gas turbine and the Hybrid Power Generation Systems planar Solid Oxide Fuel Cell (SOFC) sub-system. The overall efficiency of this system is estimated to be 43.0%. The system efficiency of the pre-baseline system provides a benchmark level for further optimization efforts in this program.

  16. Integrated Safety Management System as the Basis for Work Planning...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Integrated Safety Management System as the Basis for Work Planning and Control for Research and Development Integrated Safety Management System as the Basis for Work Planning and...

  17. FOA for the Demonstration of an Integrated Biorefinery System...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Demonstration of an Integrated Biorefinery System: Abengoa Bioenergy Biomass of Kansas, LLC FOA for the Demonstration of an Integrated Biorefinery System: Blue Fire Ethanol, Inc...

  18. FOA for the Demonstration of an Integrated Biorefinery System...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Blue Fire Ethanol, Inc. FOA for the Demonstration of an Integrated Biorefinery System: Blue Fire Ethanol, Inc. FOA for the Demonstration of an Integrated Biorefinery System: Blue...

  19. Analytical Tool Development for Aftertreatment Sub-Systems Integration...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Tool Development for Aftertreatment Sub-Systems Integration Analytical Tool Development for Aftertreatment Sub-Systems Integration 2003 DEER Conference Presentation: Detroit Diesel...

  20. Integrated Solar Thermochemical Reaction System for High Efficiency...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Integrated Solar Thermochemical Reaction System for High Efficiency Production of Electricity Integrated Solar Thermochemical Reaction System for High Efficiency Production of...

  1. 2014 SunShot Initiative Systems Integration Subprogram Overview...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Systems Integration Subprogram Overview 2014 SunShot Initiative Systems Integration Subprogram Overview These slides correspond to a presentation given by SunShot Initiative...

  2. WATER DATA MANAGEMENT SYSTEMS INTEGRATIONS WITH MODELS

    E-Print Network [OSTI]

    Rhode Island, University of

    Acquisition (SCADA) system that can control operations in treatment plants, as well as continuously check and SCADA interfaces for even more integrated analyses, which is important since many suppliers are implementing SCADA systems. However, only about thirty-five (35) percent of the suppliers have a functioning

  3. PV Integration by Building Energy Management System

    E-Print Network [OSTI]

    Boyer, Edmond

    stands for any variable that could be PV, grid power, or load power if calculation is valid for allPV Integration by Building Energy Management System Rim.Missaouią, Ghaith.Warkozeką, Seddik. BachaLab.grenoble-inp.fr Abstract- This paper focuses on Energy Management System (EMS) applied to the residential sector. The EMS

  4. An integrated mobile system for port security

    SciTech Connect (OSTI)

    Cester, D. [Dipartimento di Fisica, Universita di Padova, Via F. Marzolo 8, Padova I-35131 (Italy); Fabris, D. [INFN Sezione di Padova, Via F. Marzolo 8, Padova I-35131 (Italy); Lunardon, M.; Moretto, S. [Dipartimento di Fisica, Universita di Padova, Via F. Marzolo 8, Padova I-35131 (Italy); Nebbia, G. [INFN Sezione di Padova, Via F. Marzolo 8, Padova I-35131 (Italy); Pesente, S.; Stevanato, L.; Viesti, G. [Dipartimento di Fisica, Universita di Padova, Via F. Marzolo 8, Padova I-35131 (Italy); Neri, F.; Petrucci, S.; Selmi, S.; Tintori, C. [CAEN S.p.A., Via Vetraia 11, I-55049, Viareggio LU (Italy)

    2011-07-01T23:59:59.000Z

    An integrated mobile system for port security is presented. The system is designed to perform active investigations, by using the tagged neutron inspection technique, of suspect dangerous materials as well as passive measurements of neutrons and gamma rays to search and identify radioactive and special nuclear materials. (authors)

  5. A Formal Model of Provenance in Distributed Systems

    E-Print Network [OSTI]

    Francalanza, Adrian

    A Formal Model of Provenance in Distributed Systems Issam Souilah2 Adrian Francalanza1 Vladimiro;Motivation Trust In a Distributed System #12;Motivation Trust In a Distributed System Distribution inherent parallelism. #12;Motivation Trust In a Distributed System Distribution inherent parallelism. Distribution

  6. NREL: Transportation Research - Systems Analysis and Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid IntegrationReportTransmissionResearchNews NRELSuccessSystems

  7. Index for the Evaluation of Distributed Generation Impacts on Distribution System Luis F. Ochoa (1,2)

    E-Print Network [OSTI]

    Harrison, Gareth

    decisions that lead to the best management of the system, regarding both technical and economical aspects. Various studies have demonstrated that integration of DG in distribution networks may create technical in voltage control processes, diminish or increase losses, etc. In fact, all our knowledge about distribution

  8. Bringing Big Systems to Small Schools: Distributed Systems for Undergraduates

    E-Print Network [OSTI]

    Albrecht, Jeannie

    Bringing Big Systems to Small Schools: Distributed Systems for Undergraduates Jeannie R. Albrecht Williams College Williamstown, MA 01267 jeannie@cs.williams.edu ABSTRACT Distributed applications have, especially at small colleges, do not offer courses that focus on the design and implementation of distributed

  9. A Tree-based Forward Digest Protocol to Verify Data Integrity in Distributed Media Streaming

    E-Print Network [OSTI]

    Xu, Dongyan

    1 A Tree-based Forward Digest Protocol to Verify Data Integrity in Distributed Media Streaming a Tree-based Forward Digest Protocol (TFDP) to verify data integrity in distributed media streaming the effectiveness of TFDP. Keywords: Data integrity, message digest, and media streaming. I. INTRODUCTION Consider

  10. Measuring Advances in HVAC Distribution System Design

    SciTech Connect (OSTI)

    Franconi, E.

    1998-05-01T23:59:59.000Z

    Substantial commercial building energy savings have been achieved by improving the performance of the HV AC distribution system. The energy savings result from distribution system design improvements, advanced control capabilities, and use of variable-speed motors. Yet, much of the commercial building stock remains equipped with inefficient systems. Contributing to this is the absence of a definition for distribution system efficiency as well as the analysis methods for quantifying performance. This research investigates the application of performance indices to assess design advancements in commercial building thermal distribution systems. The index definitions are based on a first and second law of thermodynamics analysis of the system. The second law or availability analysis enables the determination of the true efficiency of the system. Availability analysis is a convenient way to make system efficiency comparisons since performance is evaluated relative to an ideal process. A TRNSYS simulation model is developed to analyze the performance of two distribution system types, a constant air volume system and a variable air volume system, that serve one floor of a large office building. Performance indices are calculated using the simulation results to compare the performance of the two systems types in several locations. Changes in index values are compared to changes in plant energy, costs, and carbon emissions to explore the ability of the indices to estimate these quantities.

  11. Northwest Habitat Institute Integrated Habitat and Biodiversity Information SystemIntegrated Habitat and Biodiversity Information System

    E-Print Network [OSTI]

    on Geospatial Information Technologies at the National Academy of Sciences; Lead for the Spatial ApplicationNorthwest Habitat Institute Integrated Habitat and Biodiversity Information SystemIntegrated Habitat and Biodiversity Information System (IBIS) for the Columbia River Basin(IBIS) for the Columbia

  12. Vitrification Facility integrated system performance testing report

    SciTech Connect (OSTI)

    Elliott, D.

    1997-05-01T23:59:59.000Z

    This report provides a summary of component and system performance testing associated with the Vitrification Facility (VF) following construction turnover. The VF at the West Valley Demonstration Project (WVDP) was designed to convert stored radioactive waste into a stable glass form for eventual disposal in a federal repository. Following an initial Functional and Checkout Testing of Systems (FACTS) Program and subsequent conversion of test stand equipment into the final VF, a testing program was executed to demonstrate successful performance of the components, subsystems, and systems that make up the vitrification process. Systems were started up and brought on line as construction was completed, until integrated system operation could be demonstrated to produce borosilicate glass using nonradioactive waste simulant. Integrated system testing and operation culminated with a successful Operational Readiness Review (ORR) and Department of Energy (DOE) approval to initiate vitrification of high-level waste (HLW) on June 19, 1996. Performance and integrated operational test runs conducted during the test program provided a means for critical examination, observation, and evaluation of the vitrification system. Test data taken for each Test Instruction Procedure (TIP) was used to evaluate component performance against system design and acceptance criteria, while test observations were used to correct, modify, or improve system operation. This process was critical in establishing operating conditions for the entire vitrification process.

  13. REAL-TIME ACTIVE PIPELINE INTEGRITY DETECTION (RAPID) SYSTEM FOR CORROSION DETECTION AND QUANTIFICATION

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    alone there are over 2 million miles of natural gas transmission and distribution pipeline providing 24REAL-TIME ACTIVE PIPELINE INTEGRITY DETECTION (RAPID) SYSTEM FOR CORROSION DETECTION detection Acellent has developed a Real-time Active Pipeline Integrity Detection (RAPID) system. The RAPID

  14. Distributed embedded computing systems are special-purpose computer systems designed for particular applications and set up in a networked or distributed manner. A

    E-Print Network [OSTI]

    Bhattacharyya, Shuvra S.

    for such a distributed system setup is the domain of wireless sensor network (WSN) applications. In this thesis, studies-specific WSN system with compact size and low power features. This system design is the result of an integrated proposed design techniques. This thesis also presents a system-level synthesis methodology for finding

  15. Short-Term Load Forecasting Error Distributions and Implications for Renewable Integration Studies: Preprint

    SciTech Connect (OSTI)

    Hodge, B. M.; Lew, D.; Milligan, M.

    2013-01-01T23:59:59.000Z

    Load forecasting in the day-ahead timescale is a critical aspect of power system operations that is used in the unit commitment process. It is also an important factor in renewable energy integration studies, where the combination of load and wind or solar forecasting techniques create the net load uncertainty that must be managed by the economic dispatch process or with suitable reserves. An understanding of that load forecasting errors that may be expected in this process can lead to better decisions about the amount of reserves necessary to compensate errors. In this work, we performed a statistical analysis of the day-ahead (and two-day-ahead) load forecasting errors observed in two independent system operators for a one-year period. Comparisons were made with the normal distribution commonly assumed in power system operation simulations used for renewable power integration studies. Further analysis identified time periods when the load is more likely to be under- or overforecast.

  16. Software communications integrated into refinery system

    SciTech Connect (OSTI)

    Goodpaster, R.; Kennedy, J.P.

    1989-01-16T23:59:59.000Z

    Ashland Oil Co. is integrating software communications, using real-time data, into the computerized information system at its Catlettsburg, Ky., refinery. The Ashland real-time information system (Artis) was designed to improve timeliness and accuracy of yield accounting to the refinery, and to standardize software communications between applications. With the system, real-time data are collected in a central data server and used to feed normal data reconciliation software for validation. This part of the system has been successfully implemented. Standardization of software communications is still under design, but most of the communication paths have been defined because a highly evolved information system already exists at the refinery. And efforts are under way to integrate information from the process to optimization.

  17. System integration test plan for HANDI 2000 business management system

    SciTech Connect (OSTI)

    Wilson, D.

    1998-08-24T23:59:59.000Z

    This document presents the system integration test plan for the Commercial-Off-The-Shelf, PassPort and PeopleSoft software, and custom software created to work with the COTS products. The PP software is an integrated application for AP, Contract Management, Inventory Management, Purchasing and Material Safety Data Sheet. The PS software is an integrated application for Project Costing, General Ledger, Human Resources/Training, Payroll, and Base Benefits.

  18. A Unified and Integrated Energy Management System for HVAC Spaces and Power House 

    E-Print Network [OSTI]

    Kaya, A.; Debban, G. D.

    1988-01-01T23:59:59.000Z

    This paper describes a totally integrated energy management system throughout the plant and facilities. The equipment involves: the power plant (boilers, cogeneration turbines, chillers); HVAC of buildings; air handling and other distribution...

  19. Avoiding Distribution System Upgrade Costs Using Distributed Generation

    SciTech Connect (OSTI)

    Schienbein, Lawrence A.; Balducci, Patrick J.; Nguyen, Tony B.; Brown, Daryl R.; DeSteese, John G.; Speer, Gregory A.

    2004-01-20T23:59:59.000Z

    PNNL, in cooperation with three utilities, developed a database and methodology to analyze and characterize the avoided costs of Distributed Generation (DG) deployment as an alternative to traditional distribution system investment. After applying a number of screening criteria to the initial set of 307 cases, eighteen were selected for detailed analysis. Alternative DG investment scenarios were developed for these cases to permit capital, operation, maintenance, and fuel costs to be identified and incorporated into the analysis. The “customer-owned” backup power generator option was also investigated. The results of the analysis of the 18 cases show that none yielded cost savings under the alternative DG scenarios. However, the DG alternative systems were configured using very restrictive assumptions concerning reliability, peak rating, engine types and acceptable fuel. In particular it was assumed that the DG alternative in each case must meet the reliability required of conventional distribution systems (99.91% reliability). The analysis was further constrained by a requirement that each substation meet the demands placed upon it by a one in three weather occurrence. To determine if, by relaxing these requirements, the DG alternative might be more viable, one project was re-examined. The 99.91% reliability factor was still assumed for normal operating conditions but redundancy required to maintain reliability was relaxed for the relatively few hours every three years where extreme weather caused load to exceed present substation capacity. This resulted in the deferment of capital investment until later years and reduced the number of engines required for the project. The cost of both the conventional and DG alternative also dropped because the centralized power generation, variable O&M, and DG fuels costs were calculated based on present load requirements in combination with long-term forecasts of load growth, as opposed to load requirements plus a buffer based on predictions of extraordinary weather conditions. Application of the relaxed set of assumptions reduced the total cost of the DG alternative by roughly 57 percent from $7.0 million to $3.0 million. The reduction, however, did not change the overall result of the analysis, as the cost of the conventional distribution system upgrade alternative remained lower at $1.7 million. This paper also explores the feasibility of using a system of backup generators to defer investment in distribution system infrastructure. Rather than expanding substation capacity at substations experiencing slow load growth rates, PNNL considered a scenario where diesel generators were installed on location at customers participating in a program designed to offer additional power security and reliability to the customer and connection to the grid. The backup generators, in turn, could be used to meet peak demand for a limited number of hours each year, thus deferring distribution system investment. Data from an existing program at one of the three participating utilities was used to quantify the costs associated with the backup generator scenario. The results of the “customer owned” backup power generator analysis showed that in all cases the nominal cost of the DG scenario is more than the nominal cost of the base-case conventional distribution system upgrade scenario. However, in two of the cases the total present value costs of the alternative backup generator scenarios were between 15 and 22% less than those for the conventional scenarios. Overall, the results of the study offer considerable encouragement that the use of DG systems can defer conventional distribution system upgrades under the right conditions and when the DG configurations are intelligently designed. Using existing customer-owned DG to defer distribution system upgrades appears to be an immediate commercially-viable opportunity.

  20. Grid Integrated Distributed PV (GridPV) Version 2.

    SciTech Connect (OSTI)

    Reno, Matthew J.; Coogan, Kyle

    2014-12-01T23:59:59.000Z

    This manual provides the documentation of the MATLAB toolbox of functions for using OpenDSS to simulate the impact of solar energy on the distribution system. The majority of the functio ns are useful for interfacing OpenDSS and MATLAB, and they are of generic use for commanding OpenDSS from MATLAB and retrieving information from simulations. A set of functions is also included for modeling PV plant output and setting up the PV plant in th e OpenDSS simulation. The toolbox contains functions for modeling the OpenDSS distribution feeder on satellite images with GPS coordinates. Finally, example simulations functions are included to show potential uses of the toolbox functions. Each function i n the toolbox is documented with the function use syntax, full description, function input list, function output list, example use, and example output.

  1. Improving Mission Execution by Integrating our Management Systems

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2011-10-03T23:59:59.000Z

    Request for analysis and preliminary set of alternatives for the integration of management systems within DOE.

  2. Optimal Real-time Dispatch for Integrated Energy Systems

    E-Print Network [OSTI]

    Firestone, Ryan Michael

    2007-01-01T23:59:59.000Z

    Hybrid Optimization Model for Electric Renewables heating, ventilation, and air conditioning integrated energy system

  3. Transmission and Grid Integration: Electricity, Resources, & Building Systems Integration (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2009-09-01T23:59:59.000Z

    Factsheet developed to describe the activites of the Transmission and Grid Integration Group within NREL's Electricity, Resources, and Buildings Systems Integration center.

  4. Convex Models of Distribution System Reconfiguration

    E-Print Network [OSTI]

    Taylor, Joshua A.

    We derive new mixed-integer quadratic, quadratically constrained, and second-order cone programming models of distribution system reconfiguration, which are to date the first formulations of the ac problem that have convex, ...

  5. PhD Recent Graduates with background in Distributed Systems. Virtualization, Distributed Systems, Application Servers or Operating Systems

    E-Print Network [OSTI]

    Plotkin, Joshua B.

    and maintenance support of the project. * Work closely with internal SAP associates, external partnersPhD Recent Graduates with background in Distributed Systems. Virtualization, Distributed Systems, Application Servers or Operating Systems Global Business Incubator Location ­ Palo Alto PURPOSE

  6. A Distributed Building Evacuation System

    E-Print Network [OSTI]

    Qumsiyeh, Dany M.

    2008-07-14T23:59:59.000Z

    This thesis investigates the feasibility of a smart building evacuation system, capable of guiding occupants along safe paths to exits and responding to changing threats. Inspired by developments in amorphous computing, ...

  7. An Integrated Low Level Heat Recovery System

    E-Print Network [OSTI]

    Sierra, A. V., Jr.

    1981-01-01T23:59:59.000Z

    A large amount of low level thermal energy is lost to air or water in a typical petroleum refinery. This paper discusses a complex integrated low level heat recovery system that is being engineered for installation in a large petroleum refinery...

  8. Energy Systems Integration A Convergence of Ideas

    E-Print Network [OSTI]

    Energy Systems Integration A Convergence of Ideas July 2012 Ben Kroposki, Bobi Garrett, Stuart Macmillan, Brent Rice, and Connie Komomua National Renewable Energy Laboratory Mark O'Malley University of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy

  9. Remote Laboratory Towards an integrated training system

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Remote Laboratory Towards an integrated training system Arnaud LELEVE, Hcene BENMOHAMED, Patrick.Meyer@ictt.ec-lyon.fr Abstract ­ Remote laboratories are essential to e-learning platforms in scientific and technical with the aim of giving means to instructors to build generic remote laboratory environments, homogeneously melt

  10. Establishing and Sustaining System Integrity via Root of Trust Installation

    E-Print Network [OSTI]

    McDaniel, Patrick Drew

    integrity. The TPM-based integrity measurement approaches are effective for measuring well-known, staticEstablishing and Sustaining System Integrity via Root of Trust Installation Abstract Integrity the management of a system's integrity, we propose a Root of Trust Installation (ROTI) as a foundation for high

  11. Integrative Genomics and Computational Systems Medicine

    SciTech Connect (OSTI)

    McDermott, Jason E.; Huang, Yufei; Zhang, Bing; Xu, Hua; Zhao, Zhongming

    2014-01-01T23:59:59.000Z

    The exponential growth in generation of large amounts of genomic data from biological samples has driven the emerging field of systems medicine. This field is promising because it improves our understanding of disease processes at the systems level. However, the field is still in its young stage. There exists a great need for novel computational methods and approaches to effectively utilize and integrate various omics data.

  12. Strategy Guideline: Compact Air Distribution Systems

    SciTech Connect (OSTI)

    Burdick, A.

    2013-06-01T23:59:59.000Z

    This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

  13. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect (OSTI)

    Faress Rahman; Nguyen Minh

    2004-01-04T23:59:59.000Z

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the July 2003 to December 2003 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a micro-turbine. In addition, an activity included in this program focuses on the development of an integrated coal gasification fuel cell system concept based on planar SOFC technology. Also, another activity included in this program focuses on the development of SOFC scale up strategies.

  14. Integration of distributed energy resources. The CERTS Microgrid Concept

    SciTech Connect (OSTI)

    Lasseter, Robert; Akhil, Abbas; Marnay, Chris; Stephens, John; Dagle, Jeff; Guttromsom, Ross; Meliopoulous, A. Sakis; Yinger, Robert; Eto, Joe

    2002-04-01T23:59:59.000Z

    Evolutionary changes in the regulatory and operational climate of traditional electric utilities and the emergence of smaller generating systems such as microturbines have opened new opportunities for on-site power generation by electricity users. In this context, distributed energy resources (DER)--small power generators typically located at users' sites where the energy (both electric and thermal) they generate is used--have emerged as a promising option to meet growing customer needs for electric power with an emphasis on reliability and power quality. The portfolio of DER includes generators, energy storage, load control, and, for certain classes of systems, advanced power electronic interfaces between the generators and the bulk power provider. This white paper proposes that the significant potential of smaller DER to meet customers' and utilities' needs can be best captured by organizing these resources into MicroGrids.

  15. Quantization of classical integrable systems. Part I: quasi-integrable quantum systems

    E-Print Network [OSTI]

    M. Marino; N. N. Nekhoroshev

    2010-01-26T23:59:59.000Z

    We propose in this work a concept of integrability for quantum systems, which corresponds to the concept of noncommutative integrability for systems in classical mechanics. We determine a condition for quantum operators which can be a suitable replacement for the condition of functional independence for functions on the classical phase space. This condition is based on the properties of the main parts of the operators with respect to the momenta. We are led in this way to the definition of what we call a "quasi-integrable quantum system". This concept will be further developed in a series of following papers.

  16. Integrated Security System | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the.pdfBreaking of BlytheDepartmentEnergy Integrated EnergyIntegrated Security System

  17. Implementation Guide for Integrating Pollution Prevention into Environmental Management Systems

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2005-05-27T23:59:59.000Z

    This Guide suggests approaches to integrating pollution prevention into Integrated Safety Management/Environmental Management Systems. Canceled by DOE N 251.82.

  18. Integrating Renewable Energy into the Transmission and Distribution...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    generation DOE U.S. Department of Energy DPR Dynamic Power Resource DS distributed storage DSM demand side management D-SMES distributed superconducting magnetic energy...

  19. Integrated Energy Systems (IES) for Buildings: A Market Assessment

    SciTech Connect (OSTI)

    LeMar, P.

    2002-10-29T23:59:59.000Z

    Integrated Energy Systems (IES) combine on-site power or distributed generation technologies with thermally activated technologies to provide cooling, heating, humidity control, energy storage and/or other process functions using thermal energy normally wasted in the production of electricity/power. IES produce electricity and byproduct thermal energy onsite, with the potential of converting 80 percent or more of the fuel into useable energy. IES have the potential to offer the nation the benefits of unprecedented energy efficiency gains, consumer choice and energy security. It may also dramatically reduce industrial and commercial building sector carbon and air pollutant emissions and increase source energy efficiency. Applications of distributed energy and Combined heat and power (CHP) in ''Commercial and Institutional Buildings'' have, however, been historically limited due to insufficient use of byproduct thermal energy, particularly during summer months when heating is at a minimum. In recent years, custom engineered systems have evolved incorporating potentially high-value services from Thermally Activated Technologies (TAT) like cooling and humidity control. Such TAT equipment can be integrated into a CHP system to utilize the byproduct heat output effectively to provide absorption cooling or desiccant humidity control for the building during these summer months. IES can therefore expand the potential thermal energy services and thereby extend the conventional CHP market into building sector applications that could not be economically served by CHP alone. Now more than ever, these combined cooling, heating and humidity control systems (IES) can potentially decrease carbon and air pollutant emissions, while improving source energy efficiency in the buildings sector. Even with these improvements over conventional CHP systems, IES face significant technological and economic hurdles. Of crucial importance to the success of IES is the ability to treat the heating, ventilation, air conditioning, water heating, lighting, and power systems loads as parts of an integrated system, serving the majority of these loads either directly or indirectly from the CHP output. The CHP Technology Roadmaps (Buildings and Industry) have focused research and development on a comprehensive integration approach: component integration, equipment integration, packaged and modular system development, system integration with the grid, and system integration with building and process loads. This marked change in technology research and development has led to the creation of a new acronym to better reflect the nature of development in this important area of energy efficiency: Integrated Energy Systems (IES). Throughout this report, the terms ''CHP'' and ''IES'' will sometimes be used interchangeably, with CHP generally reserved for the electricity and heat generating technology subsystem portion of an IES. The focus of this study is to examine the potential for IES in buildings when the system perspective is taken, and the IES is employed as a dynamic system, not just as conventional CHP. This effort is designed to determine market potential by analyzing IES performance on an hour-by-hour basis, examining the full range of building types, their loads and timing, and assessing how these loads can be technically and economically met by IES.

  20. Integrated monitoring and surveillance system demonstration project

    SciTech Connect (OSTI)

    Aumeier, S.E.; Walters, G. [Argonne National Lab., Idaho Falls, ID (United States); Kotter, D.; Walrath, W.M.; Zamecnik, R.J. [Lockheed-Martin Idaho Technologies Company, Idaho Falls, ID (United States)

    1997-07-01T23:59:59.000Z

    We present a summary of efforts associated with the installation of an integrated system for the surveillance and monitoring of stabilized plutonium metals and oxides in long-term storage. The product of this effort will include a Pu storage requirements document, baseline integrated monitoring and surveillance system (IMSS) prototype and test bed that will be installed in the Fuel Manufacturing Facility (FMF) nuclear material vault at Argonne National Laboratory - West (ANL-W), and a Pu tracking database including data analysis capabilities. The prototype will be based on a minimal set of vault and package monitoring requirements as derived from applicable DOE documentation and guidelines, detailed in the requirements document, including DOE-STD-3013-96. The use of standardized requirements will aid individual sites in the selection of sensors that best suit their needs while the prototype IMSS, located at ANL-W, will be used as a test bed to compare and contrast sensor performance against a baseline integrated system (the IMSS), demonstrate system capabilities, evaluate potential technology gaps, and test new hardware and software designs using various storage configurations. With efforts currently underway to repackage and store a substantial quantity of plutonium and plutonium-bearing material within the DOE complex, this is an opportune time to undertake such a project. 4 refs.

  1. Virtualizing Operating Systems for Seamless Distributed Environments

    E-Print Network [OSTI]

    Dasgupta, Partha

    Virtualizing Operating Systems for Seamless Distributed Environments 1 Tom Boyd and Partha Dasgupta of the "Computing Communities" project, a joint effort between Arizona State University and New York University. Abstract Applications and operating systems can be augmented with extra functionality by injecting

  2. A Distributed System for Cooperative MIMO Transmissions

    E-Print Network [OSTI]

    Kalyanaraman, Shivkumar

    a distributed system for facilitating cooperative MIMO transmissions in networks without multiple antenna diversity can be leveraged at the network, link or physical layers to provide energy efficient transmissions for reliable low-power transmissions. The rest of this paper is organized as follows: the proposed system

  3. Comprehensive Diagnosis of Complex Electrical Power Distribution Systems

    E-Print Network [OSTI]

    Daigle, Matthew

    Comprehensive Diagnosis of Complex Electrical Power Distribution Systems Indranil Roychoudhury Abstract: Electrical power distribution systems are composed of heterogeneous components, which include and discrete faults in electrical power distribution systems that include dc and ac components. We use a hybrid

  4. On-Site Wastewater Treatment Systems: Spray Distribution

    E-Print Network [OSTI]

    Lesikar, Bruce J.

    1999-09-06T23:59:59.000Z

    A spray distribution system is very similar to a lawn irrigation system. Spray heads are used to distribute treated wastewater to the surface of the yard. This publication explains the advantages and disadvantages of spray distribution systems...

  5. System specification for the integrated monitoring and surveillance system

    SciTech Connect (OSTI)

    NONE

    1997-09-01T23:59:59.000Z

    This System Specification establishes the requirements for the Plutonium Focus Area (PFA) Integrated Monitoring and Surveillance System (IMSS). In this document, ``Integrated Monitoring and Surveillance System`` is used to describe the concept of integrated sensors, computers, personnel, and systems that perform the functions of sensing conditions, acquiring data, monitoring environmental safety and health, controlling and accounting for materials, monitoring material stability, monitoring container integrity, transferring data, and analyzing, reporting, and storing data. This concept encompasses systems (e.g. sensors, personnel, databases, etc.) that are already in place at the sites but may require modifications or additions to meet all identified surveillance requirements. The purpose of this System Specification is to provide Department of Energy (DOE) sites that store plutonium materials with a consolidation of all known requirements for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides. This compilation may be used (1) as a baseline for surveillance system design specifications where 3013 packages of stabilized plutonium metals and oxides will be stored and monitored; (2) as a checklist for evaluating existing surveillance systems to ensure that all requirements are met for the storage and surveillance of 3013 packages of stabilized plutonium metals and oxides; and (3) as a baseline for preparing procurement specifications tailored for site specific storage and surveillance of 3013 packages of stabilized plutonium metals and oxides.

  6. Distributed Storage Systems for Data Intensive Computing

    SciTech Connect (OSTI)

    Vazhkudai, Sudharshan S [ORNL; Butt, Ali R [Virginia Polytechnic Institute and State University (Virginia Tech); Ma, Xiaosong [ORNL

    2012-01-01T23:59:59.000Z

    In this chapter, the authors present an overview of the utility of distributed storage systems in supporting modern applications that are increasingly becoming data intensive. Their coverage of distributed storage systems is based on the requirements imposed by data intensive computing and not a mere summary of storage systems. To this end, they delve into several aspects of supporting data-intensive analysis, such as data staging, offloading, checkpointing, and end-user access to terabytes of data, and illustrate the use of novel techniques and methodologies for realizing distributed storage systems therein. The data deluge from scientific experiments, observations, and simulations is affecting all of the aforementioned day-to-day operations in data-intensive computing. Modern distributed storage systems employ techniques that can help improve application performance, alleviate I/O bandwidth bottleneck, mask failures, and improve data availability. They present key guiding principles involved in the construction of such storage systems, associated tradeoffs, design, and architecture, all with an eye toward addressing challenges of data-intensive scientific applications. They highlight the concepts involved using several case studies of state-of-the-art storage systems that are currently available in the data-intensive computing landscape.

  7. Energy optimization of water distribution system

    SciTech Connect (OSTI)

    Not Available

    1993-02-01T23:59:59.000Z

    In order to analyze pump operating scenarios for the system with the computer model, information on existing pumping equipment and the distribution system was collected. The information includes the following: component description and design criteria for line booster stations, booster stations with reservoirs, and high lift pumps at the water treatment plants; daily operations data for 1988; annual reports from fiscal year 1987/1988 to fiscal year 1991/1992; and a 1985 calibrated KYPIPE computer model of DWSD`s water distribution system which included input data for the maximum hour and average day demands on the system for that year. This information has been used to produce the inventory database of the system and will be used to develop the computer program to analyze the system.

  8. Vol 2, Integrated Safety Management System Guide

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1999-05-27T23:59:59.000Z

    This Department of Energy (DOE) Integrated Safety Management System (ISMS) Guide is approved for use by the Office of Environment, Safety and Health (EH) and is available for use by all DOE components and their contractors. This Guide is a consensus document coordinated by EH and prepared under the direction of the DOE Safety Management Implementation Team (SMIT). Canceled by DOE G 450.4-1B.

  9. Query Answering in Data Integration Systems

    E-Print Network [OSTI]

    Salloum, Mariam

    2011-01-01T23:59:59.000Z

    the AbeBooks.com data collection. Data Integration Systemquery plans for data integration. In Data Engineering, 2002.Recursive query plans for data integration. Journal of Logic

  10. Transforming our Nation's Energy System, Energy Systems Integration Facility (ESIF)

    SciTech Connect (OSTI)

    Not Available

    2011-08-01T23:59:59.000Z

    The Energy Systems Integration Facility (ESIF) on the campus of the U.S. Department of Energy's National Renewable Energy Laboratory (NREL) will soon be the nation's first facility that can conduct integrated megawatt-scale testing of the components and strategies needed in order to safely move clean energy technologies onto the electrical grid 'in-flight' at the speed and scale required to meet national goals.

  11. Energy Efficient HVAC System for Distributed Cooling/Heating...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Efficient HVAC System for Distributed CoolingHeating with Thermoelectric Devices Energy Efficient HVAC System for Distributed CoolingHeating with Thermoelectric Devices 2012 DOE...

  12. Distributed/Stationary Fuel Cell Systems | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    DistributedStationary Fuel Cell Systems DistributedStationary Fuel Cell Systems Photo of stationary fuel cell The Department of Energy (DOE) is developing high-efficiency fuel...

  13. Energy Systems Integration | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJump to:Emminol JumpEnergy System Integration(SmithSystems

  14. Distributed Timing and Triggering Control System

    SciTech Connect (OSTI)

    Bowen, T., Huerta, J. A.

    2012-08-01T23:59:59.000Z

    This document is a slide show type presentation regarding the need and realization of a new control system for work at the Nevada National Security Site. Commercial products that met the need are identified, both hardware and software. Particular emphasis is on the Integrated Signal Programmer.

  15. NREL Leads Energy Systems Integration, Continuum Magazine: Issue 4 (Book)

    SciTech Connect (OSTI)

    Not Available

    2013-04-01T23:59:59.000Z

    Continuum Magazine showcases NREL's latest and most impactful clean energy innovations. This issue, 'NREL Leads Energy Systems Integration' explores the discipline of energy systems integration, in particular the role of the laboratory's new, one-of-a-kind Energy System Integration Facility. NREL scientists, engineers, and analysts deeply understand the fundamental science and technologies underpinning major energy producing and consuming systems, as well as the transmission infrastructure and communications and data networks required to integrate energy systems at all scales.

  16. NREL: Energy Systems Integration Facility - Integrated Deployment Workshop

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid Integration NREL is spearheadingIntegrated Deployment Workshop

  17. 1 Smart Distribution: Coupled Microgrids

    E-Print Network [OSTI]

    R. H. Lasseter

    Abstract-- The distribution system provides major opportunities for smart grid concepts. One way to approach distribution system problems is to rethinking our distribution system to include the integration of high levels of distributed energy resources, using microgrid concepts. Basic objectives

  18. Enhanced integrated nonthermal treatment system study

    SciTech Connect (OSTI)

    Biagi, C.; Schwinkendorf, B.; Teheranian, B.

    1997-02-01T23:59:59.000Z

    The purpose of the Enhanced Nonthermal Treatment Systems (ENTS) study is to evaluate alternative configurations of one of the five systems evaluated in the Integrated Nonthermal Treatment Systems (INTS) study. Five alternative configurations are evaluated. Each is designed to enhance the final waste form performance by replacing grout with improved stabilization technologies, or to improve system performance by improving the destruction efficiency for organic contaminants. AU enhanced systems are alternative configurations of System NT-5, which has the following characteristics: Nonthermal System NT-5: (1) catalytic wet oxidation (CWO) to treat organic material including organic liquids, sludges, and soft (or combustible) debris, (2) thermal desorption of inorganic sludge and process residue, (3) washing of soil and inorganic debris with treatment by CWO of removed organic material, (4) metal decontamination by abrasive blasting, (5) stabilization of treated sludge, soil, debris, and untreated debris with entrained contamination in grout, and (6) stabilization of inorganic sludge, salts and secondary waste in polymer. System NT-5 was chosen because it was designed to treat combustible debris thereby minimizing the final waste form volume, and because it uses grout for primary stabilization. The enhanced nonthermal systems were studied to determine the cost and performance impact of replacing grout (a commonly used stabilization agent in the DOE complex) with improved waste stabilization methods such as vitrification and polymer.

  19. LVT: A Layered Verification Technique for Distributed Computing Systems

    E-Print Network [OSTI]

    Olsson, Ron

    LVT: A Layered Verification Technique for Distributed Computing Systems Cui Zhang ? , Brian R of distributed computing systems with multiple component layers. Each lower layer in such a system provides languages as interfaces of systems, LVT treats each layer in a distributed computing system as a distributed

  20. Integration of distributed energy resources. The CERTS Microgrid Concept

    E-Print Network [OSTI]

    2002-01-01T23:59:59.000Z

    of Distributed Energy Resources - The C E R T S M i c r o Gof Distributed Energy Resources - The C E R T S M i c r o Gof Distributed Energy Resources - The C E R T S M i c r o G

  1. Research in Energy Systems Integration at the National Renewable Energy Laboratory

    E-Print Network [OSTI]

    Research in Energy Systems Integration at the National Renewable Energy Laboratory Speaker: Dr, renewable energy, and distributed energy resources. These efforts have started new industries Renewable Energy Laboratory in Golden, CO, where he leads a group that performs research in distributed

  2. Advanced Communication and Control for Distributed Energy Resource Integration: Phase 2 Scientific Report

    SciTech Connect (OSTI)

    BPL Global

    2008-09-30T23:59:59.000Z

    The objective of this research project is to demonstrate sensing, communication, information and control technologies to achieve a seamless integration of multivendor distributed energy resource (DER) units at aggregation levels that meet individual user requirements for facility operations (residential, commercial, industrial, manufacturing, etc.) and further serve as resource options for electric and natural gas utilities. The fully demonstrated DER aggregation system with embodiment of communication and control technologies will lead to real-time, interactive, customer-managed service networks to achieve greater customer value. Work on this Advanced Communication and Control Project (ACCP) consists of a two-phase approach for an integrated demonstration of communication and control technologies to achieve a seamless integration of DER units to reach progressive levels of aggregated power output. Phase I involved design and proof-of-design, and Phase II involves real-world demonstration of the Phase I design architecture. The scope of work for Phase II of this ACCP involves demonstrating the Phase I design architecture in large scale real-world settings while integrating with the operations of one or more electricity supplier feeder lines. The communication and control architectures for integrated demonstration shall encompass combinations of software and hardware components, including: sensors, data acquisition and communication systems, remote monitoring systems, metering (interval revenue, real-time), local and wide area networks, Web-based systems, smart controls, energy management/information systems with control and automation of building energy loads, and demand-response management with integration of real-time market pricing. For Phase II, BPL Global shall demonstrate the Phase I design for integrating and controlling the operation of more than 10 DER units, dispersed at various locations in one or more Independent System Operator (ISO) Control Areas, at an aggregated scale of more than 1 MW, to provide grid support. Actual performance data with respect to each specified function above is to be collected during the Phase II field demonstration. At a minimum, the Phase II demonstration shall span one year of field operations. The demonstration performance will need to be validated by the target customer(s) for acceptance and subsequent implementation. An ISO must be involved in demonstration planning and execution. As part of the Phase II work, BPL Global shall develop a roadmap to commercialization that identifies and quantifies the potential markets for the integrated, aggregated DER systems and for the communication and control technologies demonstrated in Phase I. In addition, the roadmap must identify strategies and actions, as well as the regional and national markets where the aggregated DER systems with communication and control solutions will be introduced, along with a timeline projected for introduction into each identified market. In Phase I of this project, we developed a proof-of-concept ACCP system and architecture and began to test its functionality at real-world sites. These sites had just over 10 MW of DERs and allowed us to identify what needed to be done to commercialize this concept. As a result, we started Phase II by looking at our existing platform and identified its strengths and weaknesses as well as how it would need to evolve for commercialization. During this process, we worked with different stakeholders in the market including: Independent System Operators, DER owners and operators, and electric utility companies to fully understand the issues from all of the different perspectives. Once we had an understanding of the commercialized ACCP system, we began to document and prepare detailed designs of the different system components. The components of the system with the most significant design improvements were: the on-site remote terminal unit, the communication technology between the remote site and the data center, and the scalability and reliability of the data center application.

  3. High temperature hot water distribution system study

    SciTech Connect (OSTI)

    NONE

    1996-12-01T23:59:59.000Z

    The existing High Temperature Hot Water (HTHW) Distribution System has been plagued with design and construction deficiencies since startup of the HTHW system, in October 1988. In October 1989, after one year of service, these deficiencies were outlined in a technical evaluation. The deficiencies included flooded manholes, sump pumps not hooked up, leaking valves, contaminated HTHW water, and no cathodic protection system. This feasibility study of the High Temperature Hot Water (HTHW) Distribution System was performed under Contract No. DACA0l-94-D-0033, Delivery Order 0013, Modification 1, issued to EMC Engineers, Inc. (EMC), by the Norfolk District Corps of Engineers, on 25 April 1996. The purpose of this study was to determine the existing conditions of the High Temperature Hot Water Distribution System, manholes, and areas of containment system degradation. The study focused on two areas of concern, as follows: * Determine existing conditions and areas of containment system degradation (leaks) in the underground carrier pipes and protective conduit. * Document the condition of underground steel and concrete manholes. To document the leaks, a site survey was performed, using state-of-the-art infrared leak detection equipment and tracer gas leak detection equipment. To document the condition of the manholes, color photographs were taken of the insides of 125 manholes, and notes were made on the condition of these manholes.

  4. Vortex Hydro Energy (TRL 5 6 System) - Advanced Integration of...

    Broader source: Energy.gov (indexed) [DOE]

    Vortex Hydro Energy (TRL 5 6 System) - Advanced Integration of Power Take-Off in VIVACE Vortex Hydro Energy (TRL 5 6 System) - Advanced Integration of Power Take-Off in VIVACE...

  5. SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION

    SciTech Connect (OSTI)

    Kurt Montgomery; Nguyen Minh

    2003-08-01T23:59:59.000Z

    This report summarizes the work performed by Honeywell during the October 2001 to December 2001 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. The conceptual and demonstration system designs were proposed and analyzed, and these systems have been modeled in Aspen Plus. Work has also started on the assembly of dynamic component models and the development of the top-level controls requirements for the system. SOFC stacks have been fabricated and performance mapping initiated.

  6. Systems Integration: Solar Energy Technologies Program (SETP) (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2009-10-01T23:59:59.000Z

    Fact sheet summarizing the goals and activities of the DOE Solar Energy Technologies Program efforts within its systems integration subprogram.

  7. ModelBased Information Integration in a Neuroscience Mediator System

    E-Print Network [OSTI]

    Ludäscher, Bertram

    Model­Based Information Integration in a Neuroscience Mediator System Bertram Lud¨ascher ? Amarnath

  8. Energy Systems Integration Laboratory (Fact Sheet), NREL (National...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    from fundamental research to applications engineering. Partners at the ESIF's Energy Systems Integration Laboratory may include: * Hydrogen equipment manufacturers * Automobile...

  9. Centralized and Distributed Generated Power Systems -A Comparison Approach

    E-Print Network [OSTI]

    White Paper Power Systems Engineering Research Center Empowering Minds to Engineer the Future ElectricCentralized and Distributed Generated Power Systems - A Comparison Approach Future Grid Initiative Energy System #12;Centralized and Distributed Generated Power Systems - A Comparison Approach Prepared

  10. Distributed Power Control in Wireless Communication Systems

    E-Print Network [OSTI]

    Chronopoulos, Anthony T.

    Distributed Power Control in Wireless Communication Systems S. Jagannathan A. T. Chronopoulos, S layered structure in that we jointly address the issue of transmitted power levels in point to point commu the transmitter power at a given node increases not only the operating life of the bat- tery but also the overall

  11. Analysis of system wide distortion in an integrated power system utilizing a high voltage DC bus and silicon carbide power devices

    E-Print Network [OSTI]

    Fallier, William F. (William Frederick)

    2007-01-01T23:59:59.000Z

    This research investigates the distortion on the electrical distribution system for a high voltage DC Integrated Power System (IPS). The analysis was concentrated on the power supplied to a propulsion motor driven by an ...

  12. FURTHER ADVANCES IN THE INTEGRATED STRUCTURAL OPTIMIZATION SYSTEM (ISOS)

    E-Print Network [OSTI]

    Papalambros, Panos

    FURTHER ADVANCES IN THE INTEGRATED STRUCTURAL OPTIMIZATION SYSTEM (ISOS) Mehran Chirehdast *,Hae in implementing an Integrated Structural Optimization System (ISOS), introduced in our earlier publications, the Integrated Structural Optimization System (ISOS). Our previous publications [5, 7, 81 bear witness to our

  13. Energy Systems Integration | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJump to:Emminol JumpEnergy System Integration(Smith 2001)Energy

  14. Energy Systems Integration | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJump to:Emminol JumpEnergy System Integration(Smith

  15. Sandia National Laboratories: Integrated Military Systems

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of ScienceandMesa del Sol HomeFacebook Twitter YouTube Flickr RSS Top DefenseIntegrated Military Systems

  16. Systems Engineering and Integration | Department of Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over Our InstagramStructureProposed Action(InsertAbout the GeothermalSystems

  17. Carbon and Water Resource Management for Water Distribution Systems

    E-Print Network [OSTI]

    Hendrickson, Thomas Peter

    2013-01-01T23:59:59.000Z

    Reliability Corporation Polyethylene Polyvinyl chloride Society of Environmental Toxicology and Chemistry Water Distribution System

  18. FOA for the Demonstration of an Integrated Biorefinery System...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Biorefinery System: POET Project Liberty, LLC FOA for the Demonstration of an Integrated Biorefinery System: Blue Fire Ethanol, Inc. Abengoa Bioenergy Biomass of Kansas, LLC...

  19. K West integrated water treatment system subproject safety analysis document

    SciTech Connect (OSTI)

    SEMMENS, L.S.

    1999-02-24T23:59:59.000Z

    This Accident Analysis evaluates unmitigated accident scenarios, and identifies Safety Significant and Safety Class structures, systems, and components for the K West Integrated Water Treatment System.

  20. RAY AND WAVE OPTICS OF INTEGRABLE AND STOCHASTIC SYSTEMS

    E-Print Network [OSTI]

    McDonald, S.W.

    2010-01-01T23:59:59.000Z

    18-22, 1979 RAY AND WAVE OPTICS OF INTEGRABLE AND STOCHASTICof the geometrical optics (ray Hamiltonian) system derivedthe classical (geometrical optics) system (1) and the state6

  1. Laser spark distribution and ignition system

    DOE Patents [OSTI]

    Woodruff, Steven (Morgantown, WV); McIntyre, Dustin L. (Morgantown, WV)

    2008-09-02T23:59:59.000Z

    A laser spark distribution and ignition system that reduces the high power optical requirements for use in a laser ignition and distribution system allowing for the use of optical fibers for delivering the low peak energy pumping pulses to a laser amplifier or laser oscillator. An optical distributor distributes and delivers optical pumping energy from an optical pumping source to multiple combustion chambers incorporating laser oscillators or laser amplifiers for inducing a laser spark within a combustion chamber. The optical distributor preferably includes a single rotating mirror or lens which deflects the optical pumping energy from the axis of rotation and into a plurality of distinct optical fibers each connected to a respective laser media or amplifier coupled to an associated combustion chamber. The laser spark generators preferably produce a high peak power laser spark, from a single low power pulse. The laser spark distribution and ignition system has application in natural gas fueled reciprocating engines, turbine combustors, explosives and laser induced breakdown spectroscopy diagnostic sensors.

  2. Distributed parallel messaging for multiprocessor systems

    DOE Patents [OSTI]

    Chen, Dong; Heidelberger, Philip; Salapura, Valentina; Senger, Robert M; Steinmacher-Burrow, Burhard; Sugawara, Yutaka

    2013-06-04T23:59:59.000Z

    A method and apparatus for distributed parallel messaging in a parallel computing system. The apparatus includes, at each node of a multiprocessor network, multiple injection messaging engine units and reception messaging engine units, each implementing a DMA engine and each supporting both multiple packet injection into and multiple reception from a network, in parallel. The reception side of the messaging unit (MU) includes a switch interface enabling writing of data of a packet received from the network to the memory system. The transmission side of the messaging unit, includes switch interface for reading from the memory system when injecting packets into the network.

  3. A new magnetic field integral measurement system

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    measurements. b. Second field integral (horizontal and vertical) measurements. c. Multipole components of first field integral measurements. 2. Translation Coil a. Multipole...

  4. Building integrated photovoltaic systems analysis: Preliminary report

    SciTech Connect (OSTI)

    none,

    1993-08-01T23:59:59.000Z

    The National Renewable Energy Laboratory (NREL) has estimated that the deployment of photovoltaics (PV) in the commercial buildings sector has the potential to contribute as much as 40 gigawatts peak electrical generation capacity and displace up to 1.1 quads of primary fuel use. A significant portion of this potential exists for smaller buildings under 25,000 square feet (2,300 square meters) in size or two stories or less, providing a strong cross over potential for residential applications as well. To begin to achieve this potential, research is needed to define the appropriate match of PV systems to energy end-uses in the commercial building sector. This report presents preliminary findings for a technical assessment of several alternative paths to integrate PV with building energy systems.

  5. INTEGRATED ENERGY EFFICIENT WINDOW-WALL SYSTEMS

    SciTech Connect (OSTI)

    Michael Arney, Ph.D.

    2002-12-31T23:59:59.000Z

    The building industry faces the challenge of reducing energy use while simultaneously improving construction methods and marketability. This paper describes the first phase of a project to address these concerns by designing an Integrated Window Wall System (IWWS) that can be commercialized. This work builds on previous research conducted during the 1990's by Lawrence Berkeley national Laboratories (LBNL). During this phase, the objective was to identify appropriate technologies, problems and issues and develop a number of design concepts. Four design concepts were developed into prototypes and preliminary energy analyses were conducted Three of these concepts (the foam wall, steel wall, and stiffened plate designs) showed particular potential for meeting the project objectives and will be continued into a second phase where one or two of the systems will be brought closer to commercialization.

  6. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect (OSTI)

    Nguyen Minh

    2002-03-31T23:59:59.000Z

    This report summarizes the work performed by Honeywell during the January 2002 to March 2002 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. For this reporting period the following activities have been carried out: {lg_bullet} Conceptual system design trade studies were performed {lg_bullet} System-level performance model was created {lg_bullet} Dynamic control models are being developed {lg_bullet} Mechanical properties of candidate heat exchanger materials were investigated {lg_bullet} SOFC performance mapping as a function of flow rate and pressure was completed

  7. Integrated radwaste treatment system. Final report

    SciTech Connect (OSTI)

    Baker, M.N.; Houston, H.M.

    1997-10-01T23:59:59.000Z

    In May 1988, the West Valley Demonstration Project (WVDP) began pretreating liquid high-level radioactive waste (HLW). This HLW was produced during spent nuclear fuel reprocessing operations that took place at the Western New York Nuclear Service Center from 1966 to 1972. Original reprocessing operations used plutonium/uranium extraction (PUREX) and thorium extraction (THOREX) processes to recover usable isotopes from spent nuclear fuel. The PUREX process produced a nitric acid-based waste stream, which was neutralized by adding sodium hydroxide to it. About two million liters of alkaline liquid HLW produced from PUREX neutralization were stored in an underground carbon steel tank identified as Tank 8D-2. The THOREX process, which was used to reprocess one core of mixed uranium-thorium fuel, resulted in about 31,000 liters of acidic waste. This acidic HLW was stored in an underground stainless steel tank identified as Tank 8D-4. Pretreatment of the HLW was carried out using the Integrated Radwaste Treatment System (IRTS), from May 1988 until May 1995. This system was designed to decontaminate the liquid HLW, remove salts from it, and encapsulate the resulting waste into a cement waste form that achieved US Nuclear Regulatory Commission (NRC) criteria for low-level waste (LLW) storage and disposal. A thorough discussion of IRTS operations, including all systems, subsystems, and components, is presented in US Department of Energy (DOE) Topical Report (DOE/NE/44139-68), Integrated Radwaste Treatment System Lessons Learned from 2 1/2 Years of Operation. This document also presents a detailed discussion of lessons learned during the first 2 1/2 years of IRTS operation. This report provides a general discussion of all phases of IRTS operation, and presents additional lessons learned during seven years of IRTS operation.

  8. The Chain-Length Distribution in Subcritical Systems

    SciTech Connect (OSTI)

    Steven Douglas Nolen

    2000-06-01T23:59:59.000Z

    The individual fission chains that appear in any neutron multiplying system provide a means, via neutron noise analysis, to unlock a wealth of information regarding the nature of the system. This work begins by determining the probability density distributions for fission chain lengths in zero-dimensional systems over a range of prompt neutron multiplication constant (K) values. This section is followed by showing how the integral representation of the chain-length distribution can be used to obtain an estimate of the system's subcritical prompt multiplication (MP). The lifetime of the chains is then used to provide a basis for determining whether a neutron noise analysis will be successful in assessing the neutron multiplication constant, k, of the system in the presence of a strong intrinsic source. A Monte Carlo transport code, MC++, is used to model the evolution of the individual fission chains and to determine how they are influenced by spatial effects. The dissertation concludes by demonstrating how experimental validation of certain global system parameters by neutron noise analysis may be precluded in situations in which the system K is relatively low and in which realistic detector efficiencies are simulated.

  9. Integrity and access control in untrusted content distribution networks

    E-Print Network [OSTI]

    Fu, Kevin E. (Kevin Edward), 1976-

    2005-01-01T23:59:59.000Z

    A content distribution network (CDN) makes a publisher's content highly available to readers through replication on remote computers. Content stored on untrusted servers is susceptible to attack, but a reader should have ...

  10. A system for distributed intrusion detection

    SciTech Connect (OSTI)

    Snapp, S.R.; Brentano, J.; Dias, G.V.; Goan, T.L.; Heberlein, L.T.; Ho, Che-Lin; Levitt, K.N.; Mukherjee, B. (California Univ., Davis, CA (USA). Div. of Computer Science); Grance, T. (Air Force Cryptologic Support Center, San Antonio, TX (USA)); Mansur, D.L.; Pon, K.L. (Lawrence Livermore National Lab., CA (USA)); Smaha, S.E. (Haystack Labs., Inc., Austin, TX (USA))

    1991-01-01T23:59:59.000Z

    The study of providing security in computer networks is a rapidly growing area of interest because the network is the medium over which most attacks or intrusions on computer systems are launched. One approach to solving this problem is the intrusion-detection concept, whose basic premise is that not only abandoning the existing and huge infrastructure of possibly-insecure computer and network systems is impossible, but also replacing them by totally-secure systems may not be feasible or cost effective. Previous work on intrusion-detection systems were performed on stand-alone hosts and on a broadcast local area network (LAN) environment. The focus of our present research is to extend our network intrusion-detection concept from the LAN environment to arbitarily wider areas with the network topology being arbitrary as well. The generalized distributed environment is heterogeneous, i.e., the network nodes can be hosts or servers from different vendors, or some of them could be LAN managers, like our previous work, a network security monitor (NSM), as well. The proposed architecture for this distributed intrusion-detection system consists of the following components: a host manager in each host; a LAN manager for monitoring each LAN in the system; and a central manager which is placed at a single secure location and which receives reports from various host and LAN managers to process these reports, correlate them, and detect intrusions. 11 refs., 2 figs.

  11. Symplectic numerical integration of Hamiltonian systems

    SciTech Connect (OSTI)

    Scovel, C.

    1989-09-11T23:59:59.000Z

    This paper describes some general techniques available for symplectic or Lie-Poisson integration and illustrate the results with some numerical computations. In this spirit, I also discuss reversible integration, equivariant integration, integration of volume preserving flows, and symplectic cellular automata. My intention is not to be exhaustive but to give a representative review. 76 refs., 5 figs.

  12. On-Site Wastewater Treatment Systems: Subsurface Drip Distribution

    E-Print Network [OSTI]

    Lesikar, Bruce J.

    1999-09-06T23:59:59.000Z

    A subsurface drip system distributes wastewater to the lawn through a system of tubing installed below the ground. This publication explains the advantages and disadvantages of subsurface drip distribution systems, as well as estimated costs...

  13. Integration of Feedstock Assembly System and Cellulosic Ethanol Conversion Models to Analyze Bioenergy System Performance

    SciTech Connect (OSTI)

    Jared M. Abodeely; Douglas S. McCorkle; Kenneth M. Bryden; David J. Muth; Daniel Wendt; Kevin Kenney

    2010-09-01T23:59:59.000Z

    Research barriers continue to exist in all phases of the emerging cellulosic ethanol biorefining industry. These barriers include the identification and development of a sustainable and abundant biomass feedstock, the assembly of viable assembly systems formatting the feedstock and moving it from the field (e.g., the forest) to the biorefinery, and improving conversion technologies. Each of these phases of cellulosic ethanol production are fundamentally connected, but computational tools used to support and inform analysis within each phase remain largely disparate. This paper discusses the integration of a feedstock assembly system modeling toolkit and an Aspen Plus® conversion process model. Many important biomass feedstock characteristics, such as composition, moisture, particle size and distribution, ash content, etc. are impacted and most effectively managed within the assembly system, but generally come at an economic cost. This integration of the assembly system and the conversion process modeling tools will facilitate a seamless investigation of the assembly system conversion process interface. Through the integrated framework, the user can design the assembly system for a particular biorefinery by specifying location, feedstock, equipment, and unit operation specifications. The assembly system modeling toolkit then provides economic valuation, and detailed biomass feedstock composition and formatting information. This data is seamlessly and dynamically used to run the Aspen Plus® conversion process model. The model can then be used to investigate the design of systems for cellulosic ethanol production from field to final product.

  14. Management of a large distributed control system development project

    SciTech Connect (OSTI)

    Gurd, D. P. (David P.)

    2002-01-01T23:59:59.000Z

    Building an accelerator at six geographically dispersed sites is quite mad, but politically expedient. The Spallation Neutron Source (SNS), currently under construction in Oak Ridge, Tennessee, combines a pulsed 1 Gev H{sup -} superconducting linac with a compressor ring to deliver 2 MW of beam power to a liquid mercury target for neutron production [1]. Accelerator components, target and experimental (neutron-scattering) instruments are being developed collaboratively by Lawrence Berkeley (Ion Source and Front End), Los Alamos (Linac), Thomas Jefferson (Cryosystems), Brookhaven (Compressor Ring), Oak Ridge (Target and Conventional Facilities) and Argonne (Neutron Scattering Instruments) National Laboratories. Similarly, a team distributed among all of the participating laboratories is developing the EPICS-based control system. this paper discusses the management model and strategies being used to address the unusual issues of organization, communication, standardization, integration and hand-off inherent in this widely-distributed project.

  15. Economic development through biomass system integration. Volumes 2--4

    SciTech Connect (OSTI)

    DeLong, M.M.

    1995-10-01T23:59:59.000Z

    Report documents a feasibility study for an integrated biomass power system, where an energy crop (alfalfa) is the feedstock for a processing plant and a power plant (integrated gasification combined cycle) in a way that benefits the facility owners.

  16. Systems Integration and the Department of Energy's Hydrogen Program: Preprint

    SciTech Connect (OSTI)

    Duffy, M. A.

    2007-03-01T23:59:59.000Z

    This paper discusses how the Systems Integration Office assists the Department of Energy's Hydrogen Program by using an integrated baseline approach to identify, define, and analyze requirements and tasks to achieve program goals.

  17. Integrated optical switching using titanium nitride micro electromechanical systems

    E-Print Network [OSTI]

    Takahashi, Satoshi, Ph. D. Massachusetts Institute of Technology

    2006-01-01T23:59:59.000Z

    This thesis reports an integrated optical wavelength specific switching device for applications in optical integrated circuits (OICs) based on micro electromechanical systems (MEMS). The device consists of a ring resonator ...

  18. Whole-building systems integration laboratory survey

    SciTech Connect (OSTI)

    Crawley, D.B. (American Consulting Engineers Council, Washington, DC (USA). Research and Management Foundation)

    1989-09-01T23:59:59.000Z

    This report was prepared for the Pacific Northwest Laboratory as a subcontracted activity by the Research Management Foundation of the American Consulting Engineers Council. The objective of the survey reported herein was to independently assess the need for a Building System Integration Laboratory from the viewpoint of academicians in the field of building science. The subcontractor-developed questionnaire was sent to 200 professors of architecture and engineering at US universities. In view of this diverse population, the 10% rate of return on the questionnaire was considered acceptable. Although the responses probably do not reflect an unbiased summary of the collective perceptions of the original population surveyed, they do provide a valid insight into the interests and concerns of the academic community with respect to building sciences issues.

  19. Non-Poissonian level spacing statistics of classically integrable quantum systems based on the Berry-Robnik approach

    E-Print Network [OSTI]

    H. Makino; S. Tasaki

    2004-03-26T23:59:59.000Z

    Along the line of thoughts of Berry and Robnik\\cite{[1]}, we investigated the gap distribution function of systems with infinitely many independent components, and discussed the level-spacing distribution of classically integrable quantum systems. The level spacing distribution is classified into three cases: Case 1: Poissonian if $\\bar{\\mu}(+\\infty)=0$, Case 2: Poissonian for large $S$, but possibly not for small $S$ if $0statistically independent, non-Poisson level spacing distributions are possible.

  20. SOLID OXIDE FUEL CELL HYBRID SYSTEM FOR DISTRIBUTED POWER GENERATION

    SciTech Connect (OSTI)

    Unknown

    2002-03-01T23:59:59.000Z

    This report summarizes the work performed by Honeywell during the July 2001 to September 2001 reporting period under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL) entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. The main objective of this project is to develop and demonstrate the feasibility of a highly efficient hybrid system integrating a planar Solid Oxide Fuel Cell (SOFC) and a turbogenerator. An internal program kickoff was held at Honeywell in Torrance, CA. The program structure was outlined and the overall technical approach for the program was presented to the team members. Detail program schedules were developed and detailed objectives were defined. Initial work has begun on the system design and pressurized SOFC operation.

  1. INTEGRATED VERTICAL AND OVERHEAD DECONTAMINATION (IVOD) SYSTEM

    SciTech Connect (OSTI)

    M.A. Ebadian, Ph.D.

    2001-01-01T23:59:59.000Z

    The deactivation and decommissioning of 1200 buildings within the U.S. Department of Energy-Office of Environmental Management complex will require the disposition of a large quantity of contaminated concrete and metal surfaces. It has been estimated that 23 million cubic meters of concrete and over 600,000 tons of metal will need disposition. The disposition of such large quantities of material presents difficulties in the area of decontamination and characterization. The final disposition of this large amount of material will take time and money as well as risk to the D&D work force. A single automated system that would decontaminate and characterize surfaces in one step would not only reduce the schedule and decrease cost during D&D operations but would also protect the D&D workers from unnecessary exposures to contaminated surfaces. This report summarizes the activities performed during FY00 and describes the planned activities for FY01. Accomplishments for FY00 include the following: Development and field-testing of characterization system; Completion of Title III design of deployment platform and decontamination unit; In-house testing of deployment platform and decontamination unit; Completion of system integration design; Identification of deployment site; and Completion of test plan document for deployment of IVOD at Rancho Seco nuclear power facility.

  2. AN INTEGRATED BIOLOGICAL CONTROL SYSTEM AT HANFORD

    SciTech Connect (OSTI)

    JOHNSON AR; CAUDILL JG; GIDDINGS RF; RODRIGUEZ JM; ROOS RC; WILDE JW

    2010-02-11T23:59:59.000Z

    In 1999 an integrated biological control system was instituted at the U.S. Department of Energy's Hanford Site. Successes and changes to the program needed to be communicated to a large and diverse mix of organizations and individuals. Efforts at communication are directed toward the following: Hanford Contractors (Liquid or Tank Waste, Solid Waste, Environmental Restoration, Science and Technology, Site Infrastructure), General Hanford Employees, and Hanford Advisory Board (Native American Tribes, Environmental Groups, Local Citizens, Washington State and Oregon State regulatory agencies). Communication was done through direct interface meetings, individual communication, where appropriate, and broadly sharing program reports. The objectives of the communication efforts was to have the program well coordinated with Hanford contractors, and to have the program understood well enough that all stakeholders would have confidence in the work performed by the program to reduce or elimated spread of radioactive contamination by biotic vectors. Communication of successes and changes to an integrated biological control system instituted in 1999 at the Department of Energy's Hanford Site have required regular interfaces with not only a diverse group of Hanford contractors (i.e., those responsible for liquid or tank waste, solid wastes, environmental restoration, science and technology, and site infrastructure), and general Hanford employees, but also with a consortium of designated stake holders organized as the Hanford Advisory Board (i.e., Native American tribes, various environmental groups, local citizens, Washington state and Oregon regulatory agencies, etc.). Direct interface meetings, individual communication where appropriate, and transparency of the biological control program were the methods and outcome of this effort.

  3. Thermal Systems Group; Electricity, Resources, & Building Systems Integration (ERBSI) (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2009-11-01T23:59:59.000Z

    Factsheet developed to describe the activites of the Thermal Systems Group within NREL's Electricity, Resources, and Buildings Systems Integration center.

  4. The design of a distributed image processing and dissemination system

    SciTech Connect (OSTI)

    Rafferty, P.; Hower, L.

    1990-01-01T23:59:59.000Z

    The design and implementation of a distributed image processing and dissemination system was undertaken and accomplished as part of a prototype communication and intelligence (CI) system, the contingency support system (CSS), which is intended to support contingency operations of the Tactical Air Command. The system consists of six (6) Sun 3/180C workstations with integrated ITEX image processors and three (3) 3/50 diskless workstations located at four (4) system nodes (INEL, base, and mobiles). All 3/180C workstations are capable of image system server functions where as the 3/50s are image system clients only. Distribution is accomplished via both local and wide area networks using standard Defense Data Network (DDN) protocols (i.e., TCP/IP, et al.) and Defense Satellite Communication Systems (DSCS) compatible SHF Transportable Satellite Earth Terminals (TSET). Image applications utilize Sun's Remote Procedure Call (RPC) to facilitate the image system client and server relationships. The system provides functions to acquire, display, annotate, process, transfer, and manage images via an icon, panel, and menu oriented Sunview{trademark} based user interface. Image spatial resolution is 512 {times} 480 with 8-bits/pixel black and white and 12/24 bits/pixel color depending on system configuration. Compression is used during various image display and transmission functions to reduce the dynamic range of image data of 12/6/3/2 bits/pixel depending on the application. Image acquisition is accomplished in real-time or near-real-time by special purpose Itex image hardware. As a result all image displays are highly interactive with attention given to subsecond response time. 3 refs., 7 figs.

  5. Integrated Ceramic Membrane System for Hydrogen Production

    SciTech Connect (OSTI)

    Schwartz, Joseph; Lim, Hankwon; Drnevich, Raymond

    2010-08-05T23:59:59.000Z

    Phase I was a technoeconomic feasibility study that defined the process scheme for the integrated ceramic membrane system for hydrogen production and determined the plan for Phase II. The hydrogen production system is comprised of an oxygen transport membrane (OTM) and a hydrogen transport membrane (HTM). Two process options were evaluated: 1) Integrated OTM-HTM reactor – in this configuration, the HTM was a ceramic proton conductor operating at temperatures up to 900°C, and 2) Sequential OTM and HTM reactors – in this configuration, the HTM was assumed to be a Pd alloy operating at less than 600°C. The analysis suggested that there are no technical issues related to either system that cannot be managed. The process with the sequential reactors was found to be more efficient, less expensive, and more likely to be commercialized in a shorter time than the single reactor. Therefore, Phase II focused on the sequential reactor system, specifically, the second stage, or the HTM portion. Work on the OTM portion was conducted in a separate program. Phase IIA began in February 2003. Candidate substrate materials and alloys were identified and porous ceramic tubes were produced and coated with Pd. Much effort was made to develop porous substrates with reasonable pore sizes suitable for Pd alloy coating. The second generation of tubes showed some improvement in pore size control, but this was not enough to get a viable membrane. Further improvements were made to the porous ceramic tube manufacturing process. When a support tube was successfully coated, the membrane was tested to determine the hydrogen flux. The results from all these tests were used to update the technoeconomic analysis from Phase I to confirm that the sequential membrane reactor system can potentially be a low-cost hydrogen supply option when using an existing membrane on a larger scale. Phase IIB began in October 2004 and focused on demonstrating an integrated HTM/water gas shift (WGS) reactor to increase CO conversion and produce more hydrogen than a standard water gas shift reactor would. Substantial improvements in substrate and membrane performance were achieved in another DOE project (DE-FC26-07NT43054). These improved membranes were used for testing in a water gas shift environment in this program. The amount of net H2 generated (defined as the difference of hydrogen produced and fed) was greater than would be produced at equilibrium using conventional water gas shift reactors up to 75 psig because of the shift in equilibrium caused by continuous hydrogen removal. However, methanation happened at higher pressures, 100 and 125 psig, and resulted in less net H2 generated than would be expected by equilibrium conversion alone. An effort to avoid methanation by testing in more oxidizing conditions (by increasing CO2/CO ratio in a feed gas) was successful and net H2 generated was higher (40-60%) than a conventional reactor at equilibrium at all pressures tested (up to 125 psig). A model was developed to predict reactor performance in both cases with and without methanation. The required membrane area depends on conditions, but the required membrane area is about 10 ft2 to produce about 2000 scfh of hydrogen. The maximum amount of hydrogen that can be produced in a membrane reactor decreased significantly due to methanation from about 2600 scfh to about 2400 scfh. Therefore, it is critical to eliminate methanation to fully benefit from the use of a membrane in the reaction. Other modeling work showed that operating a membrane reactor at higher temperature provides an opportunity to make the reactor smaller and potentially provides a significant capital cost savings compared to a shift reactor/PSA combination.

  6. Distribution System Analysis Tools for Studying High Penetration of PV

    E-Print Network [OSTI]

    Distribution System Analysis Tools for Studying High Penetration of PV with Grid Support Features Electric Energy System #12;#12;Distribution System Analysis Tools for Studying High Penetration of PV project titled "Distribution System Analysis Tools for Studying High Penetration of PV with Grid Support

  7. Guest Editorial: Special Issue on Reliable Distributed Systems

    E-Print Network [OSTI]

    Firenze, Universitŕ degli Studi di

    Guest Editorial: Special Issue on Reliable Distributed Systems Shambhu J. Upadhyaya, Senior Member, designers, and implementers of distributed systems, with emphasis on system properties such as reliability with the 19th IEEE Symposium on Reliable Distributed Systems held at Nuernberg, Germany, 2000, but the topics

  8. Integrated Chemical Geothermometry System for Geothermal Exploration

    Broader source: Energy.gov (indexed) [DOE]

    interpretations) * Reduce exploration and development costs Innovation * Numerical optimization of multicomponent chemical geothermometry at multiple locations * Integration with...

  9. A Queueing Based Scheduling Approach to Plug-In Electric Vehicle Dispatch in Distribution Systems

    E-Print Network [OSTI]

    Li, Qiao; Ilic, Marija D

    2012-01-01T23:59:59.000Z

    Large-scale integration of plug-in electric vehicles (PEV) in power systems can cause severe issues to the existing distribution system, such as branch congestions and significant voltage drops. As a consequence, smart charging strategies are crucial for the secure and reliable operation of the power system. This paper tries to achieve high penetration level of PEVs with the existing distribution system infrastructure by proposing a smart charging algorithm that can optimally utilize the distribution system capacity. Specifically, the paper proposes a max-weight PEV dispatch algorithm to control the PEV charging rates, subject to power system physical limits. The proposed max-weight PEV dispatch algorithm is proved to be throughput optimal under very mild assumptions on the stochastic dynamics in the system. This suggests that the costly distribution system infrastructure upgrade can be avoided, or failing that, at least successfully deferred. The proposed PEV dispatch algorithm is particularly attractive in ...

  10. An Architectural Approach for Integrated Network and Systems Management

    E-Print Network [OSTI]

    Boutaba, Raouf

    An Architectural Approach for Integrated Network and Systems Management Raouf Boutaba 1 and Simon. The constant growth in quantity and quality of networked systems and the thereby arising problems concerning introduce an architecture for the integrated management of all resources in a networked system, i

  11. Interconnecting PV on New York City's Secondary Network Distribution System

    SciTech Connect (OSTI)

    Anderson, K.; Coddington, M.; Burman, K.; Hayter, S.; Kroposki, B.; Watson, A.

    2009-12-01T23:59:59.000Z

    This study describes technical assistance provided by NREL to help New York City and Con Edison improve the interconnection of distributed PV systems on a secondary network distribution system.

  12. Modeling of Distributed Systems by Concurrent Regular Expressions

    E-Print Network [OSTI]

    Garg, Vijay

    Modeling of Distributed Systems by Concurrent Regular Expressions Vijay K. Garg Department of Electrical and Computer Engineering, University of Texas, Austin, TX 78712 We propose an algebraic model called concurrent regular expressions for modeling and anal- ysis of distributed systems

  13. Modeling of Distributed Systems by Concurrent Regular Expressions

    E-Print Network [OSTI]

    Garg, Vijay

    Modeling of Distributed Systems by Concurrent Regular Expressions Vijay K. Garg Department of Electrical and Computer Engineering, University of Texas, Austin, TX 78712 We propose an algebraic model called concurrent regular expressions for modeling and anal­ ysis of distributed systems

  14. Strategies and Decision Support Systems for Integrating Variable...

    Open Energy Info (EERE)

    Strategies and Decision Support Systems for Integrating Variable Energy Resources in Control Centers for Reliable Grid Operations: Global Best Practices, Examples of Excellence and...

  15. Integrated Energy Systems Multi-Media Webcast: Three CHP Sites...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Multi-Media Webcast: Three CHP Sites Yield Important Lessons Learned, September 2005 Integrated Energy Systems Multi-Media Webcast: Three CHP Sites Yield Important Lessons Learned,...

  16. Race to Zero 2015 Systems Integration Excellence Award Winners...

    Energy Savers [EERE]

    the 2015 Systems Integration Excellence Award winner presentations. Habitat for Humanity Net Zero Energy Home - Redbird Red Team Illinois State University, Normal, IL H4: Heritage...

  17. Hardware Assistance for Trustworthy Systems through 3-D Integration

    E-Print Network [OSTI]

    California at Santa Barbara, University of

    Hardware Assistance for Trustworthy Systems through 3-D Integration Jonathan Valamehr , Mohit a separate control plane, stacked using 3- D integration, that allows for the function and economics computation plane by at- taching an optional control plane using 3-D integration. In a developed example we

  18. Distributed fiber optic moisture intrusion sensing system

    DOE Patents [OSTI]

    Weiss, Jonathan D. (Albuquerque, NM)

    2003-06-24T23:59:59.000Z

    Method and system for monitoring and identifying moisture intrusion in soil such as is contained in landfills housing radioactive and/or hazardous waste. The invention utilizes the principle that moist or wet soil has a higher thermal conductance than dry soil. The invention employs optical time delay reflectometry in connection with a distributed temperature sensing system together with heating means in order to identify discrete areas within a volume of soil wherein temperature is lower. According to the invention an optical element and, optionally, a heating element may be included in a cable or other similar structure and arranged in a serpentine fashion within a volume of soil to achieve efficient temperature detection across a large area or three dimensional volume of soil. Remediation, moisture countermeasures, or other responsive action may then be coordinated based on the assumption that cooler regions within a soil volume may signal moisture intrusion where those regions are located.

  19. Sandia National Laboratories: photovoltaic systems integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Photovoltaic Regional Test Center (RTC). The RTC will enable research on integrating solar panels into the statewide smart grid and help reduce the cost of solar power. The...

  20. Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation

    SciTech Connect (OSTI)

    David Deangelis; Rich Depuy; Debashis Dey; Georgia Karvountzi; Nguyen Minh; Max Peter; Faress Rahman; Pavel Sokolov; Deliang Yang

    2004-09-30T23:59:59.000Z

    This report summarizes the work performed by Hybrid Power Generation Systems, LLC (HPGS) during the April to October 2004 reporting period in Task 2.3 (SOFC Scaleup for Hybrid and Fuel Cell Systems) under Cooperative Agreement DE-FC26-01NT40779 for the U. S. Department of Energy, National Energy Technology Laboratory (DOE/NETL), entitled ''Solid Oxide Fuel Cell Hybrid System for Distributed Power Generation''. This study analyzes the performance and economics of power generation systems for central power generation application based on Solid Oxide Fuel Cell (SOFC) technology and fueled by natural gas. The main objective of this task is to develop credible scale up strategies for large solid oxide fuel cell-gas turbine systems. System concepts that integrate a SOFC with a gas turbine were developed and analyzed for plant sizes in excess of 20 MW. A 25 MW plant configuration was selected with projected system efficiency of over 65% and a factory cost of under $400/kW. The plant design is modular and can be scaled to both higher and lower plant power ratings. Technology gaps and required engineering development efforts were identified and evaluated.

  1. Opis: Reliable Distributed Systems in OCaml Pierre-Evariste Dagand

    E-Print Network [OSTI]

    Kuncak, Viktor

    Opis: Reliable Distributed Systems in OCaml Pierre-´Evariste Dagand ENS Cachan-Bretagne, France languages provide an excellent vehicle for developing and debugging distributed systems. We present Opis, a functional-reactive approach for de- veloping distributed systems in Objective Caml. An Opis protocol

  2. Distributed Power Delivery for Energy Efficient and Low Power Systems

    E-Print Network [OSTI]

    Friedman, Eby G.

    Distributed Power Delivery for Energy Efficient and Low Power Systems Selc¸uk K¨ose Department throughout a power distribution system. Due to the parasitic impedances of the power distribution networks current to the load circuits [3]. The complexity of the high performance power delivery systems has

  3. Control and regulation of modern distribution system, ForskEL...

    Open Energy Info (EERE)

    system, ForskEL (Smart Grid Project) Jump to: navigation, search Project Name Control and regulation of modern distribution system, ForskEL Country Denmark Coordinates...

  4. 6.824 Distributed Computer Systems, Fall 2002

    E-Print Network [OSTI]

    Morris, Robert Tappan

    Abstractions and implementation techniques for design of distributed systems; server design, network programming, naming, storage systems, security, and fault tolerance. Readings from current literature. 6 Engineering ...

  5. Best Management Practice #3: Distribution System Audits, Leak...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Leaks in distribution systems are caused by a number of factors, including pipe corrosion, high system pressure, construction disturbances, frost damage, damaged joints, and...

  6. SOFC combined cycle systems for distributed generation

    SciTech Connect (OSTI)

    Brown, R.A.

    1997-05-01T23:59:59.000Z

    The final phase of the tubular SOFC development program will focus on the development and demonstration of pressurized solid oxide fuel cell (PSOFC)/gas turbine (GT) combined cycle power systems for distributed power applications. The commercial PSOFC/GT product line will cover the power range 200 kWe to 50 MWe, and the electrical efficiency for these systems will range from 60 to 75% (net AC/LHV CH4), the highest of any known fossil fueled power generation technology. The first demonstration of a pressurized solid oxide fuel cell/gas turbine combined cycle will be a proof-of-concept 250 kWe PSOFC/MTG power system consisting of a single 200 kWe PSOFC module and a 50 kWe microturbine generator (MTG). The second demonstration of this combined cycle will be 1.3 MWe fully packaged, commercial prototype PSOFC/GT power system consisting of two 500 kWe PSOFC modules and a 300 kWe gas turbine.

  7. Cathode power distribution system and method of using the same for power distribution

    DOE Patents [OSTI]

    Williamson, Mark A; Wiedmeyer, Stanley G; Koehl, Eugene R; Bailey, James L; Willit, James L; Barnes, Laurel A; Blaskovitz, Robert J

    2014-11-11T23:59:59.000Z

    Embodiments include a cathode power distribution system and/or method of using the same for power distribution. The cathode power distribution system includes a plurality of cathode assemblies. Each cathode assembly of the plurality of cathode assemblies includes a plurality of cathode rods. The system also includes a plurality of bus bars configured to distribute current to each of the plurality of cathode assemblies. The plurality of bus bars include a first bus bar configured to distribute the current to first ends of the plurality of cathode assemblies and a second bus bar configured to distribute the current to second ends of the plurality of cathode assemblies.

  8. Physical Effects of Distributed PV Generation on California's Distribution System

    E-Print Network [OSTI]

    Cohen, Michael A

    2015-01-01T23:59:59.000Z

    Deployment of high-penetration photovoltaic (PV) power is expected to have a range of effects -- both positive and negative -- on the distribution grid. The magnitude of these effects may vary greatly depending upon feeder topology, climate, PV penetration level, and other factors. In this paper we present a simulation study of eight representative distribution feeders in three California climates at PV penetration levels up to 100\\%, supported by a unique database of distributed PV generation data that enables us to capture the impact of PV variability on feeder voltage and voltage regulating equipment. When comparing the influence of feeder location (i.e. climate) versus feeder type on outcomes, we find that location more strongly influences the incidence of reverse power flow, reductions in peak loading and the presence of voltage excursions. On the other hand, we find that feeder characteristics more strongly influence the magnitude of loss reduction and changes in voltage regulator operations. We find th...

  9. Solar Energy Grid Integration Systems -- Energy Storage (SEGIS-ES).

    SciTech Connect (OSTI)

    Hanley, Charles J.; Ton, Dan T. (U.S. Department of Energy, Washington, D.C.); Boyes, John D.; Peek, Georgianne Huff

    2008-07-01T23:59:59.000Z

    This paper describes the concept for augmenting the SEGIS Program (an industry-led effort to greatly enhance the utility of distributed PV systems) with energy storage in residential and small commercial applications (SEGIS-ES). The goal of SEGIS-ES is to develop electrical energy storage components and systems specifically designed and optimized for grid-tied PV applications. This report describes the scope of the proposed SEGIS-ES Program and why it will be necessary to integrate energy storage with PV systems as PV-generated energy becomes more prevalent on the nation's utility grid. It also discusses the applications for which energy storage is most suited and for which it will provide the greatest economic and operational benefits to customers and utilities. Included is a detailed summary of the various storage technologies available, comparisons of their relative costs and development status, and a summary of key R&D needs for PV-storage systems. The report concludes with highlights of areas where further PV-specific R&D is needed and offers recommendations about how to proceed with their development.

  10. Integrated Retail and Wholesale Power System Operation with Smart-Grid Functionality

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    1 Integrated Retail and Wholesale Power System Operation with Smart-Grid Functionality Dionysios of retail and wholesale power markets operating over transmission and distribution networks with smart-grid functionality. This test bed seams together two existing test beds, the AMES Wholesale Power Market Test Bed

  11. An Integrated Air Handling Unit System for Large Commercial Buildings

    E-Print Network [OSTI]

    Song, L.; Liu, M.

    2001-01-01T23:59:59.000Z

    This paper presents an integrated air handling unit system (OAHU) for large commercial buildings. The system introduces outside air into the interior section and circulates the return air to the exterior section. Detailed analytical models...

  12. Geometric numerical integration of nonholonomic systems and optimal control problems

    E-Print Network [OSTI]

    M. de Leon; D. Martin de Diego; A. Santamaria Merino

    2002-12-02T23:59:59.000Z

    A geometric derivation of numerical integrators for nonholonomic systems and optimal control problems is obtained. It is based in the classical technique of generating functions adapted to the special features of nonholonomic systems and optimal control problems.

  13. Systems Engineering Integrating Project Management, Science, Engineering, and

    E-Print Network [OSTI]

    Mojzsis, Stephen J.

    Systems Engineering Integrating Project Management, Science, Engineering, and Mission Operations Systems Engineering Experience LASP is a full-cycle space institute, combining all aspects of space exploration through our expertise in science, engineering, mission operations, data analysis, and education

  14. Systems Engineering Integrating Project Management, Science, Engineering, and

    E-Print Network [OSTI]

    Mojzsis, Stephen J.

    Systems Engineering Integrating Project Management, Science, Engineering, and Mission Operations Systems Engineering Experience LASP is a full-cycle space research institute, combining all aspects of space exploration through our expertise in science, engineering, mission operations, data analysis

  15. Detection of contamination of municipal water distribution systems

    DOE Patents [OSTI]

    Cooper, John F. (Oakland, CA)

    2012-01-17T23:59:59.000Z

    A system for the detection of contaminates of a fluid in a conduit. The conduit is part of a fluid distribution system. A chemical or biological sensor array is connected to the conduit. The sensor array produces an acoustic signal burst in the fluid upon detection of contaminates in the fluid. A supervisory control system connected to the fluid and operatively connected to the fluid distribution system signals the fluid distribution system upon detection of contaminates in the fluid.

  16. Integrating Renewables and CHP into the UK Electricity System

    E-Print Network [OSTI]

    Watson, Andrew

    Integrating Renewables and CHP into the UK Electricity System Xueguang Wu, Nick Jenkins, Goran Report 13 #12;1 Integrating Renewables and CHP into the UK Electricity System Tyndall Centre Technical and Regional CHP Projections to 2010 ...............................................18 2.5 Scenarios

  17. A Deep Web Data Integration System for Job , Ling yanyan

    E-Print Network [OSTI]

    A Deep Web Data Integration System for Job Search Liu wei 1, Li xian 1 , Ling yanyan 1 , Zhang build a deep web data integration system that supports unified access for users to multiple job web interfaces. We call this kind of web data "Deep Web", the online databases "Web database", and the form

  18. Energy Efficiency of Distributed Environmental Control Systems

    SciTech Connect (OSTI)

    Khalifa, H. Ezzat; Isik, Can; Dannenhoffer, John F. III

    2011-02-23T23:59:59.000Z

    In this report, we present an analytical evaluation of the potential of occupant-regulated distributed environmental control systems (DECS) to enhance individual occupant thermal comfort in an office building with no increase, and possibly even a decrease in annual energy consumption. To this end we developed and applied several analytical models that allowed us to optimize comfort and energy consumption in partitioned office buildings equipped with either conventional central HVAC systems or occupant-regulated DECS. Our approach involved the following interrelated components: 1. Development of a simplified lumped-parameter thermal circuit model to compute the annual energy consumption. This was necessitated by the need to perform tens of thousands of optimization calculations involving different US climatic regions, and different occupant thermal preferences of a population of ~50 office occupants. Yearly transient simulations using TRNSYS, a time-dependent building energy modeling program, were run to determine the robustness of the simplified approach against time-dependent simulations. The simplified model predicts yearly energy consumption within approximately 0.6% of an equivalent transient simulation. Simulations of building energy usage were run for a wide variety of climatic regions and control scenarios, including traditional “one-size-fits-all” (OSFA) control; providing a uniform temperature to the entire building, and occupant-selected “have-it-your-way” (HIYW) control with a thermostat at each workstation. The thermal model shows that, un-optimized, DECS would lead to an increase in building energy consumption between 3-16% compared to the conventional approach depending on the climate regional and personal preferences of building occupants. Variations in building shape had little impact in the relative energy usage. 2. Development of a gradient-based optimization method to minimize energy consumption of DECS while keeping each occupant’s thermal dissatisfaction below a given threshold. The DECS energy usage was calculated using the simplified thermal model. OSFA control; providing a uniform temperature to the entire building, and occupant-selected HIYW control with a thermostat at each workstation were implemented for 3 cities representing 3 different climatic regions and control scenarios. It is shown that optimization allows DECS to deliver a higher level of individual and population thermal comfort while achieving annual energy savings between 14 and 26% compared to OSFA. The optimization model also allowed us to study the influence of the partitions’ thermal resistance and the variability of internal loads at each office. These influences didn’t make significant changes in the optimized energy consumption relative to OSFA. The results show that it is possible to provide thermal comfort for each occupant while saving energy compared to OSFA Furthermore, to simplify the implementation of this approach, a fuzzy logic system has been developed to generalize the overall optimization strategy. Its performance was almost as good as the gradient system. The fuzzy system provided thermal comfort to each occupant and saved energy compared to OSFA. The energy savings of the fuzzy system were not as high as for the gradient-optimized system, but the fuzzy system avoided complete connectivity, and the optimization did not have to be repeated for each population. 3. We employed a detailed CFD model of adjacent occupied cubicles to extend the thermal-circuit model in three significant ways: (a) relax the “office wall” requirement by allowing energy to flow between zones via advection as well as conduction, (b) improve the comfort model to account both for radiation as well as convection heat transfer, and (c) support ventilation systems in which the temperature is stratified, such as in underfloor air distribution systems. Initially, three-dimensional CFD simulations of several cubicle configurations, with an adjoining corridor, were performed both to understand the advection between cubicles and the

  19. Clock distribution system for digital computers

    DOE Patents [OSTI]

    Wyman, Robert H. (Brentwood, CA); Loomis, Jr., Herschel H. (Davis, CA)

    1981-01-01T23:59:59.000Z

    Apparatus for eliminating, in each clock distribution amplifier of a clock distribution system, sequential pulse catch-up error due to one pulse "overtaking" a prior clock pulse. The apparatus includes timing means to produce a periodic electromagnetic signal with a fundamental frequency having a fundamental frequency component V'.sub.01 (t); an array of N signal characteristic detector means, with detector means No. 1 receiving the timing means signal and producing a change-of-state signal V.sub.1 (t) in response to receipt of a signal above a predetermined threshold; N substantially identical filter means, one filter means being operatively associated with each detector means, for receiving the change-of-state signal V.sub.n (t) and producing a modified change-of-state signal V'.sub.n (t) (n=1, . . . , N) having a fundamental frequency component that is substantially proportional to V'.sub.01 (t-.theta..sub.n (t) with a cumulative phase shift .theta..sub.n (t) having a time derivative that may be made uniformly and arbitrarily small; and with the detector means n+1 (1.ltoreq.n

  20. Method and system of integrating information from multiple sources

    DOE Patents [OSTI]

    Alford, Francine A. (Livermore, CA); Brinkerhoff, David L. (Antioch, CA)

    2006-08-15T23:59:59.000Z

    A system and method of integrating information from multiple sources in a document centric application system. A plurality of application systems are connected through an object request broker to a central repository. The information may then be posted on a webpage. An example of an implementation of the method and system is an online procurement system.

  1. Vol 1, Integrated Safety Management System Guide,

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1997-11-26T23:59:59.000Z

    This Guide provides guidance for addressing the requirements of DOE P 450.4 and DEAR integrated SMS clauses promulgated in 48 CFR 970.5204-2, 48 CFR 970.5204-78, and 48 CFR 970.1001.

  2. Vol 2, Integrated Safety Management System Guide

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    1997-12-26T23:59:59.000Z

    This Guide provides guidance for addressing the requirements of DOE P 450.4 and DEAR integrated SMS clauses promulgated in 48 CFR 970.5204-2, 48 CFR 970.5204-78, and 48 CFR 970.1001.

  3. Update on DOE Integrated Energy Systems Projects

    E-Print Network [OSTI]

    Williams, T. E., Jr.

    1984-01-01T23:59:59.000Z

    energy audit support to small and medium sized manufacturing plants, technology transfer support in conjunction with industrial sector companies and trade associations, funding and direction of the Energy Integrated Farm program, administration...

  4. Integrated Energy and Greenhouse Gas Management System

    E-Print Network [OSTI]

    Spates, C. N.

    2010-01-01T23:59:59.000Z

    With Climate Change legislation on the horizon, the need to integrate energy reduction initiatives with greenhouse gas reduction efforts is critical to manufactures competitiveness and financial strength going forward. MPC has developed...

  5. Integrated Energy and Greenhouse Gas Management System 

    E-Print Network [OSTI]

    Spates, C. N.

    2010-01-01T23:59:59.000Z

    With Climate Change legislation on the horizon, the need to integrate energy reduction initiatives with greenhouse gas reduction efforts is critical to manufactures competitiveness and financial strength going forward. MPC ...

  6. Modeling for System Integration Studies (Presentation)

    SciTech Connect (OSTI)

    Orwig, K. D.

    2012-05-01T23:59:59.000Z

    This presentation describes some the data requirements needed for grid integration modeling and provides real-world examples of such data and its format. Renewable energy integration studies evaluate the operational impacts of variable generation. Transmission planning studies investigate where new transmission is needed to transfer energy from generation sources to load centers. Both use time-synchronized wind and solar energy production and load as inputs. Both examine high renewable energy penetration scenarios in the future.

  7. NREL: Energy Systems Integration - Research Highlights

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid Integration NREL is spearheading engineering innovations

  8. NREL: Energy Systems Integration - Research and Development

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid Integration NREL is spearheading engineering innovationsand

  9. NREL: Energy Systems Integration - Working with Us

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid Integration NREL is spearheading engineeringWebmaster

  10. STATE OF CALIFORNIA DISTRIBUTED ENERGY STORAGE DX AC SYSTEMES ACCEPTANCE

    E-Print Network [OSTI]

    STATE OF CALIFORNIA DISTRIBUTED ENERGY STORAGE DX AC SYSTEMES ACCEPTANCE CEC-MECH-14A (Revised 08/09) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF ACCEPTANCE MECH-14A NA7.5.13 Distributed Energy Storage DX AC DISTRIBUTED ENERGY STORAGE DX AC SYSTEMES ACCEPTANCE CEC-MECH-14A (Revised 08/09) CALIFORNIA ENERGY COMMISSION

  11. System Designs for Adaptive, Distributed Network Monitoring and Control

    E-Print Network [OSTI]

    Baras, John S.

    1 System Designs for Adaptive, Distributed Network Monitoring and Control H. Li, S. Yang, H. Xi.umd.edu Abstract We present system designs for adaptive, distributed network monitoring and control. The ideas are to distribute some processing intelligence to network elements, and to design a dynamic interface

  12. Reliability of Heterogeneous Distributed Computing Systems in the Presence

    E-Print Network [OSTI]

    Hayat, Majeed M.

    Reliability of Heterogeneous Distributed Computing Systems in the Presence of Correlated Failures of distributed-computing systems (DCSs) has been widely studied under the assumption that computing elements (CEs of correlated failures are also investigated. Index Terms--Distributed computing, load balancing, reliability

  13. Performance of Integrated Systems of Automated Roller Shade Systems and Daylight Responsive Dimming Systems

    SciTech Connect (OSTI)

    Park, Byoung-Chul; Choi, An-Seop; Jeong, Jae-Weon; Lee, Eleanor S.

    2010-07-08T23:59:59.000Z

    Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane illuminance according to roller shade height and sky conditions for improvement of the system accuracy. In this study, the performance of the integrated systems with two improved closed-loop proportional control algorithms was compared with that of the current (modified) closed-loop proportional control algorithm. In the results, the average maintenance percentage and the average discrepancies of the target illuminance, as well as the average time under 90percent of target illuminance for the integrated systems significantly improved in comparison with the current closed-loop proportional control algorithm for daylight responsive dimming systems as a single system.

  14. Submitted to The First World Congress on Integrated Design and Process Technology Integrated Production Systems for

    E-Print Network [OSTI]

    Foss, Bjarne A.

    and petrochemical plants, oil-processing plants including re neries, pulp and paper plants, metallurgical plantsSubmitted to The First World Congress on Integrated Design and Process Technology Integrated Production Systems for The Process Industries yBjarne A. Foss 1, zRoger Klev, zMorten Levin, xKristian Lien y

  15. Integrating Solar PV in Utility System Operations

    SciTech Connect (OSTI)

    Mills, A.; Botterud, A.; Wu, J.; Zhou, Z.; Hodge, B-M.; Heany, M.

    2013-10-31T23:59:59.000Z

    This study develops a systematic framework for estimating the increase in operating costs due to uncertainty and variability in renewable resources, uses the framework to quantify the integration costs associated with sub-hourly solar power variability and uncertainty, and shows how changes in system operations may affect these costs. Toward this end, we present a statistical method for estimating the required balancing reserves to maintain system reliability along with a model for commitment and dispatch of the portfolio of thermal and renewable resources at different stages of system operations. We estimate the costs of sub-hourly solar variability, short-term forecast errors, and day-ahead (DA) forecast errors as the difference in production costs between a case with “realistic” PV (i.e., subhourly solar variability and uncertainty are fully included in the modeling) and a case with “well behaved” PV (i.e., PV is assumed to have no sub-hourly variability and can be perfectly forecasted). In addition, we highlight current practices that allow utilities to compensate for the issues encountered at the sub-hourly time frame with increased levels of PV penetration. In this analysis we use the analytical framework to simulate utility operations with increasing deployment of PV in a case study of Arizona Public Service Company (APS), a utility in the southwestern United States. In our analysis, we focus on three processes that are important in understanding the management of PV variability and uncertainty in power system operations. First, we represent the decisions made the day before the operating day through a DA commitment model that relies on imperfect DA forecasts of load and wind as well as PV generation. Second, we represent the decisions made by schedulers in the operating day through hour-ahead (HA) scheduling. Peaking units can be committed or decommitted in the HA schedules and online units can be redispatched using forecasts that are improved relative to DA forecasts, but still imperfect. Finally, we represent decisions within the operating hour by schedulers and transmission system operators as real-time (RT) balancing. We simulate the DA and HA scheduling processes with a detailed unit-commitment (UC) and economic dispatch (ED) optimization model. This model creates a least-cost dispatch and commitment plan for the conventional generating units using forecasts and reserve requirements as inputs. We consider only the generation units and load of the utility in this analysis; we do not consider opportunities to trade power with neighboring utilities. We also do not consider provision of reserves from renewables or from demand-side options. We estimate dynamic reserve requirements in order to meet reliability requirements in the RT operations, considering the uncertainty and variability in load, solar PV, and wind resources. Balancing reserve requirements are based on the 2.5th and 97.5th percentile of 1-min deviations from the HA schedule in a previous year. We then simulate RT deployment of balancing reserves using a separate minute-by-minute simulation of deviations from the HA schedules in the operating year. In the simulations we assume that balancing reserves can be fully deployed in 10 min. The minute-by-minute deviations account for HA forecasting errors and the actual variability of the load, wind, and solar generation. Using these minute-by-minute deviations and deployment of balancing reserves, we evaluate the impact of PV on system reliability through the calculation of the standard reliability metric called Control Performance Standard 2 (CPS2). Broadly speaking, the CPS2 score measures the percentage of 10-min periods in which a balancing area is able to balance supply and demand within a specific threshold. Compliance with the North American Electric Reliability Corporation (NERC) reliability standards requires that the CPS2 score must exceed 90% (i.e., the balancing area must maintain adequate balance for 90% of the 10-min periods). The combination of representing DA forecast errors in the

  16. 1 | P a g e Implementing an Integrated Distributed Model in Finance

    E-Print Network [OSTI]

    Ollivier-Gooch, Carl

    1 | P a g e Implementing an Integrated Distributed Model in Finance There are significant changes taking place, effective today, across the University's Finance function. These changes reflect some key opportunities for our finance professionals through mentoring, talent development, career laddering, mobility

  17. AN INTEGRATED TEST ENVIRONMENT FOR DISTRIBUTED APPLICATIONS HueyDer Chu and John E Dobson

    E-Print Network [OSTI]

    Newcastle upon Tyne, University of

    1 AN INTEGRATED TEST ENVIRONMENT FOR DISTRIBUTED APPLICATIONS Huey­Der Chu and John E Dobson Centre ABSTRACT Software testing is an essential component in achieving software quality. However, it is a very, manual testing is unpopular and often inconsistently executed. Therefore, a powerful environment

  18. Integration of Renewables Via Demand Management: Highly Dispatchable and Distributed Demand Response for the Integration of Distributed Generation

    SciTech Connect (OSTI)

    None

    2012-02-11T23:59:59.000Z

    GENI Project: AutoGrid, in conjunction with Lawrence Berkeley National Laboratory and Columbia University, will design and demonstrate automated control software that helps manage real-time demand for energy across the electric grid. Known as the Demand Response Optimization and Management System - Real-Time (DROMS-RT), the software will enable personalized price signal to be sent to millions of customers in extremely short timeframes—incentivizing them to alter their electricity use in response to grid conditions. This will help grid operators better manage unpredictable demand and supply fluctuations in short time-scales —making the power generation process more efficient and cost effective for both suppliers and consumers. DROMS-RT is expected to provide a 90% reduction in the cost of operating demand response and dynamic pricing Projects in the U.S.

  19. NREL: Energy Systems Integration Facility - Visualization of Electric Power

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid Integration NREL is spearheadingIntegrated DeploymentSystem

  20. Integrated Simulation Development and Decision Support Tool-Set for Utility Market and Distributed Solar Power Generation

    SciTech Connect (OSTI)

    Daye, Tony [Green Power Labs

    2013-09-30T23:59:59.000Z

    This project will enable utilities to develop long-term strategic plans that integrate high levels of renewable energy generation, and to better plan power system operations under high renewable penetration. The program developed forecast data streams for decision support and effective integration of centralized and distributed solar power generation in utility operations. This toolset focused on real time simulation of distributed power generation within utility grids with the emphasis on potential applications in day ahead (market) and real time (reliability) utility operations. The project team developed and demonstrated methodologies for quantifying the impact of distributed solar generation on core utility operations, identified protocols for internal data communication requirements, and worked with utility personnel to adapt the new distributed generation (DG) forecasts seamlessly within existing Load and Generation procedures through a sophisticated DMS. This project supported the objectives of the SunShot Initiative and SUNRISE by enabling core utility operations to enhance their simulation capability to analyze and prepare for the impacts of high penetrations of solar on the power grid. The impact of high penetration solar PV on utility operations is not only limited to control centers, but across many core operations. Benefits of an enhanced DMS using state-of-the-art solar forecast data were demonstrated within this project and have had an immediate direct operational cost savings for Energy Marketing for Day Ahead generation commitments, Real Time Operations, Load Forecasting (at an aggregate system level for Day Ahead), Demand Response, Long term Planning (asset management), Distribution Operations, and core ancillary services as required for balancing and reliability. This provided power system operators with the necessary tools and processes to operate the grid in a reliable manner under high renewable penetration.

  1. Integrated Baseline System (IBS). Version 1.03, System Management Guide

    SciTech Connect (OSTI)

    Williams, J.R. [Pacific Northwest Lab., Richland, WA (United States); Bailey, S. [Innovative Emergency Management, Inc., Baton Rouge, LA (United States); Bower, J.C. [Bower Software Services, Kennewick, Washington (United States)

    1993-01-01T23:59:59.000Z

    This IBS System Management Guide explains how to install or upgrade the Integrated Baseline System (IBS) software package. The IBS is an emergency management planning and analysis tool that was developed under the direction of the Federal Emergency Management Agency (FEMA). This guide includes detailed instructions for installing the IBS software package on a Digital Equipment Corporation (DEC) VAX computer from the IBS distribution tapes. The installation instructions include procedures for both first-time installations and upgrades to existing IBS installations. To ensure that the system manager has the background necessary for successful installation of the IBS package, this guide also includes information on IBS computer requirements, software organization, and the generation of IBS distribution tapes. When special utility programs are used during IBS installation and setups, this guide refers you to the IBS Utilities Guide for specific instructions. This guide also refers you to the IBS Data Management Guide for detailed descriptions of some IBS data files and structures. Any special requirements for installation are not documented here but should be included in a set of installation notes that come with the distribution tapes.

  2. Scalable Distributed Automation System: Scalable Real-time Decentralized Volt/VAR Control

    SciTech Connect (OSTI)

    None

    2012-03-01T23:59:59.000Z

    GENI Project: Caltech is developing a distributed automation system that allows distributed generators—solar panels, wind farms, thermal co-generation systems—to effectively manage their own power. To date, the main stumbling block for distributed automation systems has been the inability to develop software that can handle more than 100,000 distributed generators and be implemented in real time. Caltech’s software could allow millions of generators to self-manage through local sensing, computation, and communication. Taken together, localized algorithms can support certain global objectives, such as maintaining the balance of energy supply and demand, regulating voltage and frequency, and minimizing cost. An automated, grid-wide power control system would ease the integration of renewable energy sources like solar power into the grid by quickly transmitting power when it is created, eliminating the energy loss associated with the lack of renewable energy storage capacity of the grid.

  3. A Distributed Elderly healthcare System S. Nourizadeh1,2

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    of building smart home by integrating telemedicine and home automation systems. 1 INTRODUCTION. These technologies have a key role in the development of a telehealth system and smart homes. Healthcare integrated smart home allows the tenants and their family members to benefit from a safe home environment

  4. Dynamically Quantifying and Improving the Reliability of Distributed Storage Systems

    E-Print Network [OSTI]

    Bianchini, Ricardo

    Dynamically Quantifying and Improving the Reliability of Distributed Storage Systems Rekha Bachwani-scale storage systems can be significantly improved by using bet- ter reliability metrics and more efficient on a distributed storage system based on erasure codes. We find that MinI improves relia- bility significantly

  5. Maximizing Service Reliability in Distributed Computing Systems with Random Node

    E-Print Network [OSTI]

    Hayat, Majeed M.

    Maximizing Service Reliability in Distributed Computing Systems with Random Node Failures: Theory Member, IEEE Abstract--In distributed computing systems (DCSs) where server nodes can fail permanently with nonzero probability, the system performance can be assessed by means of the service reliability, defined

  6. Water Heaters and Hot Water Distribution Systems

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01T23:59:59.000Z

    Transportation Water Heaters and Hot Water DistributionLaboratory). 2008. Water Heaters and Hot Water Distributionfor instantaneous gas water heaters; and pressure loss

  7. RELIABILITY PLANNING IN DISTRIBUTED ELECTRIC ENERGY SYSTEMS

    E-Print Network [OSTI]

    Kahn, E.

    2011-01-01T23:59:59.000Z

    and deal only with solar cogeneration units that are assumedand Distributed. cogeneration). These provide just underparameters. as conventional cogeneration units. technologies

  8. Integrated Hybrid-Simulation of Electric Power and Communications Systems

    SciTech Connect (OSTI)

    Nutaro, James J [ORNL; Kuruganti, Phani Teja [ORNL; Miller, Laurie E [ORNL; Mullen, Sara [ORNL; Shankar, Mallikarjun [ORNL

    2007-01-01T23:59:59.000Z

    The modern power grid is strongly integrated with its communication network. While a power system primarily consists of elements that are modeled by continuous equations, a communication system has discrete event dynamics. We model the integrated operation of these two systems with a hybrid modeling and simulation technique. Systematically combining continuous and discrete event system models is necessary for correctly simulating critical system behaviors. This paper discusses an approach based on the discrete event system specification (DEVS) that characterizes the interaction of the two systems formally to preserve simulation correctness. We demonstrate the implementation of our integrated hybrid simulation technique with detailed generator and network models in a wide-area cooperative automatic load-control scenario.

  9. NREL: Energy Systems Integration Facility - Research Electrical

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit |

  10. Laser spark distribution and ignition system - Energy Innovation...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    power pulse. The laser spark distribution and ignition system has application in natural gas fueled reciprocating engines, turbine combustors, explosives and laser induced...

  11. Carbon and Water Resource Management for Water Distribution Systems

    E-Print Network [OSTI]

    Hendrickson, Thomas Peter

    2013-01-01T23:59:59.000Z

    23 4.5 Water-Energy SustainabilityWater Distribution System Water-energy Sustainability ToolWastewater-energy Sustainability Tool v   Acknowledgements

  12. Global integrated drought monitoring and prediction system

    E-Print Network [OSTI]

    Kimball, Sarah

    for a global drought early warning system1 . Drought effects are incremental and happen over a long period food to avoid food crises requires advanced drought early warning and prediction systems. In particular for International Development (USAID) Famine Early Warning System Network (FEWS Net)11 , United States Drought

  13. Integrated approaches to the optimal design of multiscale systems

    E-Print Network [OSTI]

    Lovelady, Eva Marie

    2009-05-15T23:59:59.000Z

    This work is aimed at development of systematic approaches to the design of multiscale systems. Specifically four problems are addressed: environmental impact assessment (EIA) of new and retrofitted industrial processes, integration of process...

  14. Departmental Integrated Safety Management System (9-23-10)

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2010-09-23T23:59:59.000Z

    This directive will convert and consolidate DOE M 450.4-1, Integrated Safety Management System Manual and DOE M 411.1-1C, Safety Management Functions, Responsibilities, and Authorities Manual into a single Order.

  15. An Energy Preserving Time Integration Method for Gyric Systems...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Preserving Time Integration Method for Gyric Systems: Development of the Offshore Wind Energy Simulation Toolkit Brian C. Owens Texas A&M University brianowens@tamu.edu John E....

  16. IntegromeDB: an integrated system and biological search engine

    E-Print Network [OSTI]

    Baitaluk, Michael; Kozhenkov, Sergey; Dubinina, Yulia; Ponomarenko, Julia

    2012-01-01T23:59:59.000Z

    Wright A: Searching the Deep Web. CACM 2008, 51(10):14-15.a semantic, graph based, ‘deep web’ data integration systemIntegromeDB to tap into the Deep Web, the portion of the web

  17. Integrated Energy Systems (IES) for Buildings: A Market Assessment...

    Open Energy Info (EERE)

    topics related to ESI Prospects for Nuclear Power(Davis 2012) A Framework for the Optimization of Integrated Energy Systems(Jain and Alleyne 2012) more Group members (12)...

  18. Novel turbomachinery concepts for highly integrated airframe/propulsion systems

    E-Print Network [OSTI]

    Shah, Parthiv N

    2007-01-01T23:59:59.000Z

    Two novel turbomachinery concepts are presented as enablers to advanced flight missions requiring integrated airframe/propulsion systems. The first concept is motivated by thermal management challenges in low-to-high Mach ...

  19. Integral reactor system and method for fuel cells

    DOE Patents [OSTI]

    Fernandes, Neil Edward; Brown, Michael S; Cheekatamarla, Praveen; Deng, Thomas; Dimitrakopoulos, James; Litka, Anthony F

    2013-11-19T23:59:59.000Z

    A reactor system is integrated internally within an anode-side cavity of a fuel cell. The reactor system is configured to convert hydrocarbons to smaller species while mitigating the lower production of solid carbon. The reactor system may incorporate one or more of a pre-reforming section, an anode exhaust gas recirculation device, and a reforming section.

  20. GSpace: Tailorable Data Distribution in Shared Data Space Systems

    E-Print Network [OSTI]

    Mousavi, Mohammad

    GSpace: Tailorable Data Distribution in Shared Data Space Systems Giovanni Russello1, Michel. The shared data space model has proven to be an effective paradigm for building distributed applications. However, building an efficient distributed implementation remains a challenge. A plethora of different

  1. NREL: Energy Systems Integration Facility - October 2011 Energy Systems

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What's Possible for Renewable Energy: Grid Integration NREL is spearheadingIntegrated Deployment

  2. NREL: Energy Systems Integration Facility - Awards

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | NationalWebmaster ToStaff

  3. NREL: Energy Systems Integration Facility - Capabilities

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | NationalWebmaster ToStaffCapabilities The Energy

  4. NREL: Energy Systems Integration Facility - Contact Us

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | NationalWebmaster ToStaffCapabilities The

  5. NREL: Energy Systems Integration Facility - Facility Design

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | NationalWebmaster ToStaffCapabilities TheFacility

  6. NREL: Energy Systems Integration Facility - Research Infrastructure

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit |Infrastructure The foundation of the Energy

  7. NREL: Energy Systems Integration Facility - Research Themes

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit |Infrastructure The foundation of the EnergyThemes

  8. NREL: Energy Systems Integration Facility - Specialized Laboratories

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit |Infrastructure The foundation of the

  9. NREL: Energy Systems Integration Home Page

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit |Infrastructure The foundation ofThermalPhoto of a

  10. NREL: Innovation Impact - Energy Systems Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit |Infrastructure The foundationBioenergy Menu

  11. Updating Interconnection Screens for PV System Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrinceton PlasmaAfternoon TalksDigitalRevisionof Energy |Michael

  12. Vehicle Systems Integration Laboratory | Clean Energy | ORNL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level:Energy: Grid Integration Redefining What'sis Taking Over OurThe Iron SpinPrincetonUsing Maps1 - USAF Wind Power ProgramDeslippe,N AVehicle

  13. Integrating Solar PV in Utility System Operations

    E-Print Network [OSTI]

    Mills, A.

    2014-01-01T23:59:59.000Z

    Laboratory National Renewable Energy Laboratory Universityof Energy Efficiency and Renewable Energy (Solar EnergySystem Operations Table 27. Renewable Curtailment in the BR

  14. Updating Interconnection Screens for PV System Integration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Abraham Ellis, Roger Hill Sandia National Laboratories Tom Key, Kristen Nicole, Jeff Smith Electric Power Research Institute Updating Interconnection Screens for PV System...

  15. Integrating Environmental, Safety, and Quality Management System...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    registrationvalidation of management systems is desirableUT-Battelle registrations ISO 9001 for isotope development process ISO 14001 for all UT-Battelle activities OHSAS...

  16. Review of the integrated thermal and nonthermal treatment system studies

    SciTech Connect (OSTI)

    NONE

    1996-08-01T23:59:59.000Z

    This report contains a review and evaluation of three systems analysis studies performed by LITCO on integrated thermal treatment systems and integrated nonthermal treatment systems for the remediation of mixed low-level waste stored throughout the US Department of Energy weapons complex. The review was performed by an independent team of nine researchers from the Energy and Environmental Research Center, Science Applications International Corporation, the Waste Policy Institute, and Virginia Tech. The three studies reviewed were as follows: Integrated Thermal Treatment System Study, Phase 1--issued July 1994; Integrated Thermal Treatment System Study, Phase 2--issued February 1996; and Integrated Nonthermal Treatment System Study--drafted March 1996. The purpose of this review was to (1) determine whether the assumptions of the studies were adequate to produce an unbiased review of both thermal and nonthermal systems, (2) to identify the critical areas of the studies that would benefit from further investigation, and (3) to develop a standard template that could be used in future studies to assure a sound application of systems engineering.

  17. Integrated Nuclear-Renewable Energy Systems: Foundational Workshop Report

    SciTech Connect (OSTI)

    Shannon Bragg-Sitton; Richard Boardman; John Collins; Mark Ruth; Owen Zinaman; Charles Forsberg

    2014-08-01T23:59:59.000Z

    The U.S. Department of Energy (DOE) recognizes the need to transform the energy infrastructure of the U.S. and elsewhere to systems that can drastically reduce environmental impacts in an efficient and economically viable manner while utilizing both hydrocarbon resources and clean energy generation sources. Thus, DOE is supporting research and development that could lead to more efficient utilization of clean energy generation sources, including renewable and nuclear options. A concept being advanced by the DOE Offices of Nuclear Energy (NE) and Energy Efficiency and Renewable Energy (EERE) is tighter coupling of nuclear and renewable energy sources in a manner that produces new energy currency for the combined electricity grid, industrial manufacturing, and the transportation energy sectors. This integration concept has been referred to as a “hybrid system” that is capable of providing the right type of energy, at the right time, in the right place. At the direction of DOE-NE and DOE-EERE leadership, project leads at Idaho National Laboratory (INL), National Renewable Energy Laboratory (NREL) and Massachusetts Institute of Technology (MIT) have identified and engaged stakeholders in discussing integrated energy systems that would optimize renewable and nuclear energy integration on a region-by-region basis. Subsequent work will entail conduct of technical, economic, environmental and socio-political evaluations of the leading integrated system options based on a set of criteria established with stakeholder input. The Foundational Workshop for Integrated Nuclear – Renewable Energy Systems was organized around the following objectives: 1. Identify and refine priority region-specific opportunities for integrated nuclear-renewable energy systems in the U.S.; 2. Select Figures of Merit (FOM) to rank and prioritize candidate systems; 3. Discuss enabling technology development needs; 4. Identify analysis requirements, capabilities and gaps to estimate FOM for integrated system options; 5. Identify experimental needs to develop and demonstrate nuclear-renewable energy systems.

  18. Integrating externally developed systems for SNS Linac cooling and vacuum.

    SciTech Connect (OSTI)

    Marroquin, P. S. (Pilar S.)

    2001-01-01T23:59:59.000Z

    External contractors are developing the local cooling and vacuum control systems for the Spallation Neutron Source (SNS) linac. Soon these systems will be integrated into the facility-wide controls system. Allen-Bradley Logix5000 series programmable controllers, populated with appropriate input/output modules, were selected as the local controllers. These controllers will be interfaced to the facility-wide control system via VME systems with PowerPC processors running the Wind River VxWorks operating system and Experimental Physics and Industrial Control System (EPICS) front-end controller software. This paper describes the interface and integration issues driven by project, cooling system and vacuum system requirements and hardware selections.

  19. Integrable and superintegrable Hamiltonian systems with four dimensional real Lie algebras as symmetry of the systems

    E-Print Network [OSTI]

    J. Abedi-Fardad; A. Rezaei-Aghdam; Gh. Haghighatdoost

    2014-05-26T23:59:59.000Z

    We construct integrable and superintegrable Hamiltonian systems using the realizations of four dimensional real Lie algebras as a symmetry of the system with the phase space R4 and R6. Furthermore, we construct some integrable and superintegrable Hamiltonian systems for which the symmetry Lie group is also the phase space of the system.

  20. Integrated intelligent systems in advanced reactor control rooms

    SciTech Connect (OSTI)

    Beckmeyer, R.R.

    1989-01-01T23:59:59.000Z

    An intelligent, reactor control room, information system is designed to be an integral part of an advanced control room and will assist the reactor operator's decision making process by continuously monitoring the current plant state and providing recommended operator actions to improve that state. This intelligent system is an integral part of, as well as an extension to, the plant protection and control systems. This paper describes the interaction of several functional components (intelligent information data display, technical specifications monitoring, and dynamic procedures) of the overall system and the artificial intelligence laboratory environment assembled for testing the prototype. 10 refs., 5 figs.

  1. Enhanced Recovery Utilizing Variable Frequency Drives and a Distributed Power System

    SciTech Connect (OSTI)

    Randy Peden; Sanjiv Shah

    2005-07-26T23:59:59.000Z

    This report describes complete results of the project entitled ''Enhanced Recovery Utilizing Variable Frequency Drives and a Distributed Power System''. This demonstration project was initiated in July 2003 and completed in March 2005. The objective of the project was to develop an integrated power production/variable frequency drive system that could easily be deployed in the oil field that would increase production and decrease operating costs. This report describes all the activities occurred and documents results of the demonstration.

  2. Numerical Analysis of a Cold Air Distribution System

    E-Print Network [OSTI]

    Zhu, L.; Li, R.; Yuan, D.

    2006-01-01T23:59:59.000Z

    Cold air distribution systems may reduce the operating energy consumption of air-conditioned air supply system and improve the outside air volume percentages and indoor air quality. However, indoor temperature patterns and velocity field are easily...

  3. Review of the integrated thermal and nonthermal treatment system studies

    SciTech Connect (OSTI)

    Durrani, H.A.; Schmidt, L.J.; Erickson, T.A.; Sondreal, E.A.; Erjavec, J.; Steadman, E.N.; Fabrycky, W.J.; Wilson, J.S.; Musich, M.A.

    1996-07-01T23:59:59.000Z

    This report analyzes three systems engineering (SE) studies performed on integrated thermal treatment systems (ITTSs) and integrated nonthermal treatment systems (INTSs) for the remediation of mixed low-level waste (MLLW) stored throughout the US Department of Energy (DOE) weapons complex. The review was performed by an independent team of nine researchers from the Energy and Environmental Research Center (EERC), Science Applications International Corporation (SAIC), the Waste Policy Institute (WPI), and Virginia Tech (VT). The three studies reviewed were as follows: Integrated Thermal Treatment System Study, Phase 1--issued July 1994; Integrated Thermal Treatment System Study, Phase 2--issued February 1996; and Integrated Nonthermal Treatment System Study--drafted March 1996. The purpose of this review was to (1) determine whether the assumptions taken in the studies might bias the resulting economic evaluations of both thermal and nonthermal systems, (2) identify the critical areas of the studies that would benefit from further investigation, and (3) develop a standard template that could be used in future studies to produce sound SE applications.

  4. Analysis Model for Domestic Hot Water Distribution Systems: Preprint

    SciTech Connect (OSTI)

    Maguire, J.; Krarti, M.; Fang, X.

    2011-11-01T23:59:59.000Z

    A thermal model was developed to estimate the energy losses from prototypical domestic hot water (DHW) distribution systems for homes. The developed model, using the TRNSYS simulation software, allows researchers and designers to better evaluate the performance of hot water distribution systems in homes. Modeling results were compared with past experimental study results and showed good agreement.

  5. THE DEVELOPMENT OF DISTRI-bution systems poses new challenges

    E-Print Network [OSTI]

    Dixon, Juan

    are covered in a separate article. The six articles in this issue review the past, present, and the future level to respond to new energy challenges and the restruc- tured environment. The need for a change in the distribution systems of the 21st century. The Past Toward the end of the 19th century, dc distribution systems

  6. On Correlated Availability in Internet-Distributed Systems Derrick Kondo

    E-Print Network [OSTI]

    Boyer, Edmond

    On Correlated Availability in Internet-Distributed Systems Derrick Kondo INRIA, France dkondo measure and characterize the time dynamics of availability in a large-scale Internet- distributed system with over 110,000 hosts. Our char- acterization focuses on identifying patterns of corre- lated availability

  7. Integrated systems analysis of the PIUS reactor

    SciTech Connect (OSTI)

    Fullwood, F.; Kroeger, P.; Higgins, J. [Brookhaven National Lab., Upton, NY (United States)] [and others

    1993-11-01T23:59:59.000Z

    Results are presented of a systems failure analysis of the PIUS plant systems that are used during normal reactor operation and postulated accidents. This study was performed to provide the NRC with an understanding of the behavior of the plant. The study applied two diverse failure identification methods, Failure Modes Effects & Criticality Analysis (FMECA) and Hazards & Operability (HAZOP) to the plant systems, supported by several deterministic analyses. Conventional PRA methods were also used along with a scheme for classifying events by initiator frequency and combinations of failures. Principal results of this study are: (a) an extensive listing of potential event sequences, grouped in categories that can be used by the NRC, (b) identification of support systems that are important to safety, and (c) identification of key operator actions.

  8. Sustainability. Systems integration for global sustainability.

    E-Print Network [OSTI]

    2015-01-01T23:59:59.000Z

    study of the energy-water nexus. Sustainability 2, 945–962 (sustainability studies have fo- cused on flows of real material and energysustainability have been place- based even if they look at coupled systems [for example, the energy-

  9. Integrated computational system for portable retinal imaging

    E-Print Network [OSTI]

    Boggess, Jason (Jason Robert)

    2012-01-01T23:59:59.000Z

    This thesis introduces a system to improve image quality obtained from a low-light CMOS camera-specifically designed to image the surface of the retina. The retinal tissue, as well as having various diseases of its own, ...

  10. PhotoVoltaic distributed generation for Lanai power grid real-time simulation and control integration scenario.

    SciTech Connect (OSTI)

    Robinett, Rush D., III; Kukolich, Keith (Opal RT Technologies, Montreal, Quebec, Canada); Wilson, David Gerald; Schenkman, Benjamin L.

    2010-06-01T23:59:59.000Z

    This paper discusses the modeling, analysis, and testing in a real-time simulation environment of the Lanai power grid system for the integration and control of PhotoVoltaic (PV) distributed generation. The Lanai Island in Hawaii is part of the Hawaii Clean Energy Initiative (HCEI) to transition to 30% renewable green energy penetration by 2030. In Lanai the primary loads come from two Castle and Cook Resorts, in addition to residential needs. The total peak load profile is 12470 V, 5.5 MW. Currently there are several diesel generators that meet these loading requirements. As part of the HCEI, Lanai has initially installed 1.2 MW of PV generation. The goal of this study has been to evaluate the impact of the PV with respect to the conventional carbon-based diesel generation in real time simulation. For intermittent PV distributed generation, the overall stability and transient responses are investigated. A simple Lanai 'like' model has been developed in the Matlab/Simulink environment (see Fig. 1) and to accommodate real-time simulation of the hybrid power grid system the Opal-RT Technologies RT-Lab environment is used. The diesel generators have been modelled using the SimPowerSystems toolbox swing equations and a custom Simulink module has been developed for the High level PV generation. All of the loads have been characterized primarily as distribution lines with series resistive load banks with one VAR load bank. Three-phase faults are implemented for each bus. Both conventional and advanced control architectures will be used to evaluate the integration of the PV onto the current power grid system. The baseline numerical results include the stable performance of the power grid during varying cloud cover (PV generation ramping up/down) scenarios. The importance of assessing the real-time scenario is included.

  11. Genalogical approaches to ethical implications of informational assimilative integrated discovery systems (AIDS) in business

    SciTech Connect (OSTI)

    Pharhizgar, K.D.; Lunce, S.E. [Texas A & M International Univ., Lardeo, TX (United States)

    1994-12-31T23:59:59.000Z

    Development of knowledge-based technological acquisition techniques and customers` information profiles are known as assimilative integrated discovery systems (AIDS) in modern organizations. These systems have access through processing to both deep and broad domains of information in modern societies. Through these systems organizations and individuals can predict future trend probabilities and events concerning their customers. AIDSs are new techniques which produce new information which informants can use without the help of the knowledge sources because of the existence of highly sophisticated computerized networks. This paper has analyzed the danger and side effects of misuse of information through the illegal, unethical and immoral access to the data-base in an integrated and assimilative information system as described above. Cognivistic mapping, pragmatistic informational design gathering, and holistic classifiable and distributive techniques are potentially abusive systems whose outputs can be easily misused by businesses when researching the firm`s customers.

  12. Systems Integration Competitive Awards | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33Frequently AskedEnergyIssues DOE'sSummaryDepartment of SustainXBetterProjectsSystemsSystems

  13. Performance and Economic Analysis of Distributed Power Electronics in Photovoltaic Systems

    SciTech Connect (OSTI)

    Deline, C.; Marion, B.; Granata, J.; Gonzalez, S.

    2011-01-01T23:59:59.000Z

    Distributed electronics like micro-inverters and DC-DC converters can help recover mismatch and shading losses in photovoltaic (PV) systems. Under partially shaded conditions, the use of distributed electronics can recover between 15-40% of annual performance loss or more, depending on the system configuration and type of device used. Additional value-added features may also increase the benefit of using per-panel distributed electronics, including increased safety, reduced system design constraints and added monitoring and diagnostics. The economics of these devices will also become more favorable as production volume increases, and integration within the solar panel?s junction box reduces part count and installation time. Some potential liabilities of per-panel devices include increased PV system cost, additional points of failure, and an insertion loss that may or may not offset performance gains under particular mismatch conditions.

  14. Integrated Hydrogen Production, Purification and Compression System

    E-Print Network [OSTI]

    -system complexity. · Increase efficiency by: ­ directly producing high-purity hydrogen using high temperature, H2 in hot water or hot air. 100 50 Step 2: Hot fluid heats the alloy causing the hydrogen to be released Hydride Alloy 2 Hydride Alloy 3 Hydride Alloy 4 Hot Fluid Cold Fluid Metal Hydride Hydrogen Compressor

  15. Integrated photoelectrochemical cell and system having a liquid electrolyte

    DOE Patents [OSTI]

    Deng, Xunming (Sylvania, OH); Xu, Liwei (Sylvania, OH)

    2010-07-06T23:59:59.000Z

    An integrated photoelectrochemical (PEC) cell generates hydrogen and oxygen from water while being illuminated with radiation. The PEC cell employs a liquid electrolyte, a multi-junction photovoltaic electrode, and a thin ion-exchange membrane. A PEC system and a method of making such PEC cell and PEC system are also disclosed.

  16. Web Service Access Management for Integration with Agent Systems

    E-Print Network [OSTI]

    Web Service Access Management for Integration with Agent Systems B.J. Overeinder, P.D. Verkaik, from the perspective of agent systems (and not as is gen- erally the case by web service providers). Mediating between web service requests from (virtual) organizations of agents, the web ser- vice gateway

  17. Information Security and Computer Systems: An Integrated Approach

    E-Print Network [OSTI]

    Holliday, Mark A.

    Information Security and Computer Systems: An Integrated Approach Mark A. Holliday Dept curriculum we are developing an Information Security option. Our approach highlights the many topics in information security that build upon concepts the students will already have seen in their computer systems

  18. FULLY INTEGRATED ONE PHASE LIQUID COOLING SYSTEM FOR ORGANIC BOARDS

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    FULLY INTEGRATED ONE PHASE LIQUID COOLING SYSTEM FOR ORGANIC BOARDS D. May1 , B. Wunderle1 , F approach: A liquid cooling system has to be cus- tomised to its application. Further, it requires many dis in designing liquid cooling solu- tions are performance, reliability and price. To that end a one-phase liquid

  19. (UR-16) Integrated Framework for Lifecycle Infrastructure Management Systems

    E-Print Network [OSTI]

    Hammad, Amin

    1 (UR-16) Integrated Framework for Lifecycle Infrastructure Management Systems Cheng Zhang1 Elaheh throughout the lifecycle of an infrastructure system, such as a bridge, including construction, inspection only limited support for representing and visualizing this information. Using a 4D product model

  20. GPS System Integration and Field Approaches in Precision Farming

    E-Print Network [OSTI]

    Calgary, University of

    GPS System Integration and Field Approaches in Precision Farming G. LACHAPELLE. M. E. CANNON. and H Alberta using differential GPS (DGPS I combined with crop yield monitors and electromagnetic fEM) ground collection, and data organization using a geographic information system (GE). Several field tests were

  1. Minimizing Energy Consumption in a Water Distribution System: A Systems Modeling Approach

    E-Print Network [OSTI]

    Johnston, John

    2011-08-08T23:59:59.000Z

    In a water distribution system from groundwater supply, the bulk of energy consumption is expended at pump stations. These pumps pressurize the water and transport it from the aquifer to the distribution system and to elevated storage tanks. Each...

  2. Integrated Demand Controlled Ventilation for Single Duct VAV System with Conference Rooms 

    E-Print Network [OSTI]

    Yu, Y.; Liu, M.; Cho, Y.; Xu, K.

    2007-01-01T23:59:59.000Z

    INTEGRATED DEMAND CONTROLLED VENTILATION FOR SINGLE DUCT VAV SYSTEM WITH CONFERENCE ROOMS Yuebin Yu Mingsheng Liu YoungHum Cho Ke Xu Graduate Student Professor of Architectural Engineering, PhD, PE Graduate.... The total OA intake of IDCV is obtained with the occupancy time ratio considered. The real time distribution of the occupancy and un-occupancy doesn’t much influence the overall calculation. With the amount of OA intake and the local BIN data...

  3. A DISTRIBUTED AUTOMATION SYSTEM FOR ELECTROPHYSICAL INSTALLATIONS

    E-Print Network [OSTI]

    Kozak, Victor R.

    on CAMAC devices. Growing requirements to functions, parameters and reliability of automation components and distributing panels between terminal equipment and control devices implemented in CAMAC standard. For avoiding this problem there was decided to implement new devices as embedded devices into end equipment. We assumed

  4. Economic development through biomass system integration: Volume 1

    SciTech Connect (OSTI)

    DeLong, M.M. [Northern States Power Co., Minneapolis, MN (United States)

    1995-10-01T23:59:59.000Z

    This report documents a feasibility study for an integrated biomass power system, where an energy crop (alfalfa) is the feedstock for a processing plant and a power plant (integrated gasification combined cycle) in a way that benefits the facility owners. Chapters describe alfalfa basics, production risks, production economics, transportation and storage, processing, products, market analysis, business analysis, environmental impact, and policy issues. 69 figs., 63 tabs.

  5. Hybrid Control Network Intrusion Detection Systems for Automated Power Distribution Systems

    E-Print Network [OSTI]

    Parvania, Masood; Koutsandria, Georgia; Muthukumar, Vishak; Peisert, Sean; McParland, Chuck; Scaglione, Anna

    2014-01-01T23:59:59.000Z

    Security protocols against cyber attacks in the distributioncyber security weak- ness and system fragility of power distribution

  6. TIME INTEGRATED MEASUREMENTS OF THE ACTIVITY-WEIGHTED SIZE DISTRIBUTION OF RADON PROGENY by

    E-Print Network [OSTI]

    William C. Tetley P. E; Daniel R. Westcott; Bruce A. Cununings

    The dose to the lung is dependent on the size distribution as well as the concentration of radon progeny. The principal indicator of particle size is the diffusion coefficient. The diffusion coefficient of radon progeny is the most important parameter in determining whether the particle will deposit its alpha energy in the tracheobronchial region of the respiratory tract. Due to the importance of the size distribution of progeny when characterizing health effects, a detector was developed that exploits the difference in diffusion coefficients to provide integrated measurements of the activity-weighted size distribution. Several radon chamber tests were performed in which the diffusion coefficient and unattached fraction of radon progeny were varied by the use of trace gasses and aerosol particles. The technical feasibility of this new detector design was demonstrated in all cases.

  7. Notice of Intent to Issue Funding Opportunity for Integrated PV and Energy Storage Systems

    Broader source: Energy.gov [DOE]

    As solar power plants proliferate, the variability and uncertainty of the solar resource poses challenges for integrating PV with electric power systems at both the distribution and bulk system levels. In response to these challenges, the U.S. Department of Energy Office of Energy Efficiency and Renewable Energy (EERE) has issued a notice of intent (NOI) to release the SunShot Sustainable and Holistic IntegratioN of Energy storage and Solar (SHINES) funding opportunity. SHINES will enable the holistic design, development, and widespread sustainable deployment of low-cost, flexible, and reliable energy storage solutions, and will strive to successfully integrate these solutions into PV power plants. SHINES projects can also focus on demand response and load management to achieve target metrics.

  8. Distributed Energy System Validation, Commissioning and

    E-Print Network [OSTI]

    ................................................................................................................... 4 2.2 Sunny Boy PV Inverter System................................................................................ 9 3.1 PV System to Sunny Boy Inverter............................................................................ 9 3.2 Sunny Boy Inverter to PV Sub

  9. An analysis of distributed solar fuel systems

    E-Print Network [OSTI]

    Thomas, Alex, S.M. Massachusetts Institute of Technology

    2012-01-01T23:59:59.000Z

    While solar fuel systems offer tremendous potential to address global clean energy needs, most existing analyses have focused on the feasibility of large centralized systems and applications. Not much research exists on ...

  10. World Class Boilers and Steam Distribution System

    E-Print Network [OSTI]

    Portell, V. P.

    “World class” is a term used to describe steam systems that rank in the top 20% of their industry based on quantitative system performance data and energy management for the facility. The rating is determined through a proceduralized assessment...

  11. Digital I and C system upgrade integration technique

    SciTech Connect (OSTI)

    Huang, H. W. [Inst. of Nuclear Energy Research (INER), No. 1000, Wenhua Road, Chiaan Village, Longtan Township, Taoyuan County, 32546, Taiwan (China); Shih, C. [Inst. of Nuclear Engineering and Science, National Tsing Hua Univ., 101, Sec. 2, Kuang Fu Rd, Hsinchu, Taiwan (China); Wang, J. R. [Inst. of Nuclear Energy Research (INER), No. 1000, Wenhua Road, Chiaan Village, Longtan Township, Taoyuan County, 32546, Taiwan (China); Huang, K. C. [Inst. of Nuclear Engineering and Science, National Tsing Hua Univ., 101, Sec. 2, Kuang Fu Rd, Hsinchu, Taiwan (China)

    2012-07-01T23:59:59.000Z

    This work developed an integration technique for digital I and C system upgrade, the utility can replace the I and C systems step by step systematically by this method. Inst. of Nuclear Energy Research (INER) developed a digital Instrumentation and Control (I and C) replacement integration technique on the basis of requirement of the three existing nuclear power plants (NPPs), which are Chin-Shan (CS) NPP, Kuo-Sheng (KS) NPP, and Maanshan (MS) NPP, in Taiwan, and also developed the related Critical Digital Review (CDR) Procedure. The digital I and C replacement integration technique includes: (I) Establishment of Nuclear Power Plant Digital Replacement Integration Guideline, (2) Preliminary Investigation on I and C System Digitalization, (3) Evaluation on I and C System Digitalization, and (4) Establishment of I and C System Digitalization Architectures. These works can be a reference for performing I and C system digital replacement integration of the three existing NPPs of Taiwan Power Company (TPC). A CDR is the review for a critical system digital I and C replacement. The major reference of this procedure is EPRI TR- 1011710 (2005) 'Handbook for Evaluating Critical Digital Equipment and Systems' which was published by the Electric Power Research Inst. (EPRI). With this document, INER developed a TPC-specific CDR procedure. Currently, CDR becomes one of the policies for digital I and C replacement in TPC. The contents of this CDR procedure include: Scope, Responsibility, Operation Procedure, Operation Flow Chart, CDR review items. The CDR review items include the comparison of the design change, Software Verification and Validation (SVandV), Failure Mode and Effects Analysis (FMEA), Evaluation of Diversity and Defense-in-depth (D3), Evaluation of Watchdog Timer, Evaluation of Electromagnetic Compatibility (EMC), Evaluation of Grounding for System/Component, Seismic Evaluation, Witness and Inspection, Lessons Learnt from the Digital I and C Failure Events. A solid review can assure the quality of the digital I and C system replacement. (authors)

  12. This paper appeared in the Proceedings of the 18th International Conference on Parallel and Distributed Computing Systems, September 12-14, 2005.

    E-Print Network [OSTI]

    Qin, Xiao

    , security control manager, security-aware scheduling, real-time applications, distributed systems. 1 by the system if the task's minimal security requirements cannot be met. This process is essential because and Distributed Computing Systems, September 12-14, 2005. Towards a Security Service Integration Framework

  13. APT Blanket System Model Based on Initial Conceptual Design - Integrated 1D TRAC System Model

    SciTech Connect (OSTI)

    Hamm, L.L.

    1998-10-07T23:59:59.000Z

    This report documents the approaches taken in establishing a 1-dimensional integrated blanket system model using the TRAC code, developed by Los Alamos National Laboratory.

  14. Process modeling for the Integrated Nonthermal Treatment System (INTS) study

    SciTech Connect (OSTI)

    Brown, B.W.

    1997-04-01T23:59:59.000Z

    This report describes the process modeling done in support of the Integrated Nonthermal Treatment System (INTS) study. This study was performed to supplement the Integrated Thermal Treatment System (ITTS) study and comprises five conceptual treatment systems that treat DOE contract-handled mixed low-level wastes (MLLW) at temperatures of less than 350{degrees}F. ASPEN PLUS, a chemical process simulator, was used to model the systems. Nonthermal treatment systems were developed as part of the INTS study and include sufficient processing steps to treat the entire inventory of MLLW. The final result of the modeling is a process flowsheet with a detailed mass and energy balance. In contrast to the ITTS study, which modeled only the main treatment system, the INTS study modeled each of the various processing steps with ASPEN PLUS, release 9.1-1. Trace constituents, such as radionuclides and minor pollutant species, were not included in the calculations.

  15. Updating Interconnection Screens for PV System Integration

    SciTech Connect (OSTI)

    Coddington, M.; Mather, B.; Kroposki, B.; Lynn, K.; Razon, A.; Ellis, A.; Hill, R.; Key, T.; Nicole, K.; Smith, J.

    2012-02-01T23:59:59.000Z

    This white paper evaluates the origins and usefulness of the capacity penetration screen, offer short-term solutions which could effectively allow fast-track interconnection to many PV system applications, and considers longer-term solutions for increasing PV deployment levels in a safe and reliable manner while reducing or eliminating the emphasis on the penetration screen. Short-term and longer-term alternatives approaches are offered as examples; however, specific modifications to screening procedures should be discussed with stakeholders and must ultimately be adopted by state and federal regulatory bodies.

  16. Energy Systems Integration | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489 No revision|LLC Place: Ketchum,SPARQLFailed to loadEnergySystems

  17. Energy Systems Integration | OpenEI Community

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489 No revision|LLC Place: Ketchum,SPARQLFailed toEnergy Systems

  18. Calculation of beam paths in optical systems containing inhomogeneous isotropic media with cylindrical distribution of the refractive index

    SciTech Connect (OSTI)

    Grammatin, A.P.; Degen, A.B.; Katranova, N.A. [Vavilov State Optical Institute, St. Petersburg (Russian Federation)

    1995-06-01T23:59:59.000Z

    A system of differential equations convenient for numerical computer integrating is proposed to calculate beam paths, elementary astigmatic beams, and the optical path in isotropic media with cylindrical distribution of the refractive index. A method for selecting the step of this integration is proposed. This technique is implemented in the program package for computers of the VAX series meant for the computer-aided design of optical systems. 4 refs.

  19. Co-simulation of innovative integrated HVAC systems in buildings

    SciTech Connect (OSTI)

    Trcka, Marija; Hensena, Jan L.M.; Wetter, Michael

    2010-06-21T23:59:59.000Z

    Integrated performance simulation of buildings HVAC systems can help in reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation, as an integrated approach to simulation. This article elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in the here described co-simulation prototype. The prototype is validated with the results obtained from the traditional simulation approach. It is further used in a proof-of-concept case study to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling time step.

  20. Modeling and Verification of Distributed Generation and Voltage Regulation Equipment for Unbalanced Distribution Power Systems; Annual Subcontract Report, June 2007

    SciTech Connect (OSTI)

    Davis, M. W.; Broadwater, R.; Hambrick, J.

    2007-07-01T23:59:59.000Z

    This report summarizes the development of models for distributed generation and distribution circuit voltage regulation equipment for unbalanced power systems and their verification through actual field measurements.

  1. NREL: Electric Infrastructure Systems Research - Distributed Energy

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | NationalWebmaster To contactK-12 Students

  2. Integrating Security and Systems Engineering: Towards the Modelling of Secure Information Systems

    E-Print Network [OSTI]

    Integrating Security and Systems Engineering: Towards the Modelling of Secure Information Systems for information systems. Traditionally, security is considered after the definition of the system. However the health sector to military. As the use of Information Systems arises, the demand to secure those systems

  3. NREL: Energy Systems Integration Facility - About the Energy Systems

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOE Office of Science (SC)Integrated CodesTransparency Visit | NationalWebmaster ToStaff WebmasterIntegration

  4. A computer system for access to distributed genome mapping data

    SciTech Connect (OSTI)

    Marr, T.G.

    1992-02-05T23:59:59.000Z

    Development of a computer system for access to distributed genome mapping data is continuing. This effort is to develop software which accesses multiple databases and retrieves data which contain information useful for accelerating mapping human chromosomes. For example, the molecular sequence databases (GenBank, EMBL Data Library, PIR, SwissProt) which contain data required for the development of oligonucleotides for probing DNA as well as for extracting data for primer pair development for PCR-based methods. It is also to develop software which qualitatively integrates the following mapping data: (1) markers regionally localized using cytogenetic methods, (2) polymorphic markers ordered by genetic linkage analysis, (3) clones ordered by various finger-printing'' methods, (4) fragments ordered by long-range restriction mapping, (5) single genomic fragments or clones that have STSs assigned to them, (6) nucleotide sequences, (7) the associated metadata such as the submitting investigator's name, location, etc; the source organism; the chromosome the element is from; the chromosomal location is whatever detail is available.

  5. Concurrency control in heterogeneous distributed database systems

    E-Print Network [OSTI]

    Rahman, Md. Rezaur

    1992-01-01T23:59:59.000Z

    APPROACHES IN HDDBS . III. A Approaches Requiring Local DBMS Modihcations 17 19 III. B Approaches Without Local DBMS Modifications 22 IV A NEW APPROACH TO HDDBS CONCURRENCY CONTROL 30 IV. A The Concurrency Control Scheme 30 CIIA PTER Page IV. B... related to Database Systems in general which will be used consistently throughout this thesis. A Database system (DBS) consists of a set of dutiibiises (DB) which contain the data of interest and software, the database msnageinent system (DBMS), which...

  6. Laser Spark Distribution and Ignition System

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    laser spark from a single low power pulse. The system has ap- plications in natural gas fueled reciprocating engines, turbine combustors, explosives, and laser induced...

  7. Seismic Fragility of the LANL Fire Water Distribution System

    SciTech Connect (OSTI)

    Greg Mertz

    2007-03-30T23:59:59.000Z

    The purpose of this report is to present the results of a site-wide system fragility assessment. This assessment focuses solely on the performance of the water distribution systems that supply Chemical and Metallurgy Research (CMR), Weapons Engineering and Tritium Facility (WETF), Radioactive Liquid Waste Treatment Facility (RLWTF), Waste Characterization, Reduction, Repackaging Facility (WCRRF), and Transuranic Waste Inspectable Storage Project (TWISP). The analysis methodology is based on the American Lifelines Alliance seismic fragility formulations for water systems. System fragilities are convolved with the 1995 LANL seismic hazards to develop failure frequencies. Acceptance is determined by comparing the failure frequencies to the DOE-1020 Performance Goals. This study concludes that: (1) If a significant number of existing isolation valves in the water distribution system are closed to dedicate the entire water system to fighting fires in specific nuclear facilities; (2) Then, the water distribution systems for WETF, RLWTF, WCRRF, and TWISP meet the PC-2 performance goal and the water distribution system for CMR is capable of surviving a 0.06g earthquake. A parametric study of the WETF water distribution system demonstrates that: (1) If a significant number of valves in the water distribution system are NOT closed to dedicate the entire water system to fighting fires in WETF; (2) Then, the water distribution system for WETF has an annual probability of failure on the order of 4 x 10{sup -3} that does not meet the PC-2 performance goal. Similar conclusions are expected for CMR, RLWTF, WCRRF, and TWISP. It is important to note that some of the assumptions made in deriving the results should be verified by personnel in the safety-basis office and may need to be incorporated in technical surveillance requirements in the existing authorization basis documentation if credit for availability of fire protection water is taken at the PC-2 level earthquake levels. Assumptions are presented in Section 2.2 of this report.

  8. Attack Detection and Identification in Cyber-Physical Systems -- Part II: Centralized and Distributed Monitor Design

    E-Print Network [OSTI]

    Pasqualetti, Fabio; Bullo, Francesco

    2012-01-01T23:59:59.000Z

    Cyber-physical systems integrate computation, communication, and physical capabilities to interact with the physical world and humans. Besides failures of components, cyber-physical systems are prone to malicious attacks so that specific analysis tools and monitoring mechanisms need to be developed to enforce system security and reliability. This paper builds upon the results presented in our companion paper [1] and proposes centralized and distributed monitors for attack detection and identification. First, we design optimal centralized attack detection and identification monitors. Optimality refers to the ability of detecting (respectively identifying) every detectable (respectively identifiable) attack. Second, we design an optimal distributed attack detection filter based upon a waveform relaxation technique. Third, we show that the attack identification problem is computationally hard, and we design a sub-optimal distributed attack identification procedure with performance guarantees. Finally, we illustr...

  9. THE DISTRIBUTED SPACECRAFT ATTITUDE CONTROL SYSTEM SIMULATOR

    E-Print Network [OSTI]

    Hall, Christopher D.

    compensation of an under-actuated system and coupled attitude control and energy storage techniques. Formation. INTRODUCTION Complex space systems are often both high-visibility and high-risk. However, programs that might@vt.edu 1 #12;custom hardware and software we have developed. The body of the paper presents information

  10. Integrated hydrocarbon reforming system and controls

    DOE Patents [OSTI]

    Clawson, Lawrence G.; Dorson, Matthew H.; Mitchell, William L.; Nowicki, Brian J.; Thijssen, Johannes; Davis, Robert; Papile, Christopher; Rumsey, Jennifer W.; Longo, Nathan; Cross, III, James C.; Rizzo, Vincent; Kleeburg, Gunther; Rindone, Michael; Block, Stephen G.; Sun, Maria; Morriseau, Brian D.; Hagan, Mark R.; Bowers, Brian

    2003-11-04T23:59:59.000Z

    A hydrocarbon reformer system including a first reactor configured to generate hydrogen-rich reformate by carrying out at least one of a non-catalytic thermal partial oxidation, a catalytic partial oxidation, a steam reforming, and any combinations thereof, a second reactor in fluid communication with the first reactor to receive the hydrogen-rich reformate, and having a catalyst for promoting a water gas shift reaction in the hydrogen-rich reformate, and a heat exchanger having a first mass of two-phase water therein and configured to exchange heat between the two-phase water and the hydrogen-rich reformate in the second reactor, the heat exchanger being in fluid communication with the first reactor so as to supply steam to the first reactor as a reactant is disclosed. The disclosed reformer includes an auxiliary reactor configured to generate heated water/steam and being in fluid communication with the heat exchanger of the second reactor to supply the heated water/steam to the heat exchanger.

  11. Review of the integrated thermal and nonthermal treatment system studies

    SciTech Connect (OSTI)

    NONE

    1996-10-01T23:59:59.000Z

    This report contains a review and evaluation of three systems analysis studies performed by LITCO on integrated thermal treatment systems and integrated nonthermal treatment systems for the remediation of mixed low-level waste stored throughout the US Department of Energy weapons complex. The review was performed by an independent team of nine researchers from the Energy and Environmental Research Center, Science Applications International Corporation, the Waste Policy Institute, and Virginia Tech. The purpose of this review was to (1) determine whether the assumptions of the studies were adequate to produce an unbiased review of both thermal and nonthermal systems, (2) to identify the critical areas of the studies that would benefit from further investigation, and (3) to develop a standard template that could be used in future studies to assure a sound application of systems engineering.

  12. Ductless Hydronic Distribution Systems | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011AT&T,Office of Policy,Policy ActDetroit7471Site-WideonDuctless Hydronic Distribution

  13. Distributed Generation Systems Inc | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489 No revision| Open Energy Information At1986)Distributed

  14. A Smart Energy System: Distributed Resource Management, Control and Optimization

    E-Print Network [OSTI]

    Beigl, Michael

    A Smart Energy System: Distributed Resource Management, Control and Optimization Yong Ding, Student of distributed energy resource and consumption management, which proposes to design a networked and embedded platform for realizing a dynamic energy mix and optimizing the energy consumption dy- namically. Based

  15. NREL: Distributed Grid Integration - Energy System Basics Video Series

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Saleshttp://www.fnal.gov/directorate/nalcal/nalcal02_07_05_files/nalcal.gifNREL NRELChemicalIndustryIssue

  16. Integrating Renewable Energy into the Transmission and Distribution System

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(FactDepartment of EnergyIndustry Research U.S.Biomaterials | Departmentof the

  17. On the Equivalence of Distributed Systems with Queries and Communication

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    On the Equivalence of Distributed Systems with Queries and Communication Serge Abiteboul INRIA, such as evaluate some query. We study the equivalence of such systems. We model a dis- tributed system such as sending, receiving and querying data. As our model is quite general, the equivalence problem turns out

  18. Princeton Power Systems (TRL 5 6 Component)- Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

    Broader source: Energy.gov [DOE]

    Princeton Power Systems (TRL 5 6 Component) - Marine High-Voltage Power Conditioning and Transmission System with Integrated Energy Storage

  19. Power-Demand Routing in massive geo-distributed systems

    E-Print Network [OSTI]

    Qureshi, Asfandyar

    2010-01-01T23:59:59.000Z

    There is an increasing trend toward massive, geographically distributed systems. The largest Internet companies operate hundreds of thousands of servers in multiple geographic locations, and are growing at a fast clip. A ...

  20. A Calculus for Access Control in Distributed Systems 

    E-Print Network [OSTI]

    Abadi, Martin; Burrows, Michael; Lampson, Butler; Plotkin, Gordon

    1993-01-01T23:59:59.000Z

    We study some of the concepts, protocols, and algorithms for access control in distributed systems, from a logical perspective. We account for how a principal may come to believe that another principal is making a request, ...

  1. RELIABILITY PLANNING IN DISTRIBUTED ELECTRIC ENERGY SYSTEMS

    E-Print Network [OSTI]

    Kahn, E.

    2011-01-01T23:59:59.000Z

    Problems and Research Needs, EPRI EL-377-SR, February 1977.Electric Utility Systems, EPRI, EM-336, November, 1976. 24.of Large Generating Units EPRI WS-77-50, February 1978.

  2. Voices of Experience | Advanced Distribution Management Systems...

    Office of Environmental Management (EM)

    systems and a move from reactive to predictive models increases the need for electrical engineering knowledge and IT skills in the operations center as well as in the fi eld. It...

  3. World Class Boilers and Steam Distribution System 

    E-Print Network [OSTI]

    Portell, V. P.

    2002-01-01T23:59:59.000Z

    environmental impacts are mitigated. Successful upgrading and maintenance of the energy system requires management support. This may necessitate changes in current practices, technical upgrades to equipment, additional personnel, or other resources. Managers...

  4. System team composition for a complex system to enable integration and attribute management

    E-Print Network [OSTI]

    Krishnaswami, Ram, 1966-

    2004-01-01T23:59:59.000Z

    The automatic transmission is a very complex system in a modern automobile with several hundred components performing mechanical, hydraulic and electronic functions. System integration and attribute management are key ...

  5. An integrated modeling framework for infrastructure system-of-systems simulation

    E-Print Network [OSTI]

    de Weck, Olivier L.

    Design of future hard infrastructure must consider emergent behaviors from cross-system interdependencies. Understanding these interdependencies is challenging due to high levels of integration in high-performance systems ...

  6. Advanced Inverter Technology for High Penetration Levels of PV Generation in Distribution Systems

    SciTech Connect (OSTI)

    Schauder, C.

    2014-03-01T23:59:59.000Z

    This subcontract report was completed under the auspices of the NREL/SCE High-Penetration Photovoltaic (PV) Integration Project, which is co-funded by the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE) and the California Solar Initiative (CSI) Research, Development, Demonstration, and Deployment (RD&D) program funded by the California Public Utility Commission (CPUC) and managed by Itron. This project is focused on modeling, quantifying, and mitigating the impacts of large utility-scale PV systems (generally 1-5 MW in size) that are interconnected to the distribution system. This report discusses the concerns utilities have when interconnecting large PV systems that interconnect using PV inverters (a specific application of frequency converters). Additionally, a number of capabilities of PV inverters are described that could be implemented to mitigate the distribution system-level impacts of high-penetration PV integration. Finally, the main issues that need to be addressed to ease the interconnection of large PV systems to the distribution system are presented.

  7. Distributed Sensor Coordination for Advanced Energy Systems

    SciTech Connect (OSTI)

    Tumer, Kagan

    2013-07-31T23:59:59.000Z

    The ability to collect key system level information is critical to the safe, efficient and reli- able operation of advanced energy systems. With recent advances in sensor development, it is now possible to push some level of decision making directly to computationally sophisticated sensors, rather than wait for data to arrive to a massive centralized location before a decision is made. This type of approach relies on networked sensors (called “agents” from here on) to actively collect and process data, and provide key control deci- sions to significantly improve both the quality/relevance of the collected data and the as- sociating decision making. The technological bottlenecks for such sensor networks stem from a lack of mathematics and algorithms to manage the systems, rather than difficulties associated with building and deploying them. Indeed, traditional sensor coordination strategies do not provide adequate solutions for this problem. Passive data collection methods (e.g., large sensor webs) can scale to large systems, but are generally not suited to highly dynamic environments, such as ad- vanced energy systems, where crucial decisions may need to be reached quickly and lo- cally. Approaches based on local decisions on the other hand cannot guarantee that each agent performing its task (maximize an agent objective) will lead to good network wide solution (maximize a network objective) without invoking cumbersome coordination rou- tines. There is currently a lack of algorithms that will enable self-organization and blend the efficiency of local decision making with the system level guarantees of global decision making, particularly when the systems operate in dynamic and stochastic environments. In this work we addressed this critical gap and provided a comprehensive solution to the problem of sensor coordination to ensure the safe, reliable, and robust operation of advanced energy systems. The differentiating aspect of the proposed work is in shift- ing the focus towards “what to observe” rather than “how to observe” in large sensor networks, allowing the agents to actively determine both the structure of the network and the relevance of the information they are seeking to collect. In addition to providing an implicit coordination mechanism, this approach allows the system to be reconfigured in response to changing needs (e.g., sudden external events requiring new responses) or changing sensor network characteristics (e.g., sudden changes to plant condition). Outcome Summary: All milestones associated with this project have been completed. In particular, private sensor objective functions were developed which are aligned with the global objective function, sensor effectiveness has been improved by using “sensor teams,” system efficiency has been improved by 30% using difference evaluation func- tions, we have demonstrated system reconfigurability for 20% changes in system con- ditions, we have demonstrated extreme scalability of our proposed algorithm, we have demonstrated that sensor networks can overcome disruptions of up to 20% in network conditions, and have demonstrated system reconfigurability to 20% changes in system conditions in hardware-based simulations. This final report summarizes how each of these milestones was achieved, and gives insight into future research possibilities past the work which has been completed. The following publications support these milestones [6, 8, 9, 10, 16, 18, 19].

  8. Abstract--The reliability and quality of power distribution systems are usually affected by many different distribution faults.

    E-Print Network [OSTI]

    Chow, Mo-Yuen

    1 Abstract--The reliability and quality of power distribution systems are usually affected by many and to provide a more effective fault restoration system. Index Terms-- power distribution systems, statistical analysis, tree-caused distribution faults. I. INTRODUCTION OWER systems play a very important role in our

  9. Correspondence between classical dynamics and energy level spacing distribution in the transition billiard systems

    E-Print Network [OSTI]

    Soo-Young Lee; Sunghwan Rim; Eui-Soon Yim; C. H. Lee

    1998-09-05T23:59:59.000Z

    The Robnik billiard is investigated in detail both classically and quantally in the transition range from integrable to almost chaotic system. We find out that a remarkable correspondence between characteristic features of classical dynamics, especially topological structure of integrable regions in the Poincar\\'{e} surface of section, and the statistics of energy level spacings appears with a system parameter $\\lambda$ being varied. It is shown that the variance of the level spacing distribution changes its behavior at every particular values of $\\lambda$ in such a way that classical dynamics changes its topological structure in the Poincar\\'{e} surface of section, while the skewness and the excess of the level spacings seem to be closely relevant to the interface structure between integrable region and chaotic sea rather than inner structure of intergrable regoin.

  10. Systems and methods for an integrated electrical sub-system powered by wind energy

    DOE Patents [OSTI]

    Liu, Yan (Ballston Lake, NY); Garces, Luis Jose (Niskayuna, NY)

    2008-06-24T23:59:59.000Z

    Various embodiments relate to systems and methods related to an integrated electrically-powered sub-system and wind power system including a wind power source, an electrically-powered sub-system coupled to and at least partially powered by the wind power source, the electrically-powered sub-system being coupled to the wind power source through power converters, and a supervisory controller coupled to the wind power source and the electrically-powered sub-system to monitor and manage the integrated electrically-powered sub-system and wind power system.

  11. Overview of Space Business Space & Integrated Defense Systems

    E-Print Network [OSTI]

    Overview of Space Business Space & Integrated Defense Systems Mitsubishi Corporation August 26 in Rio de Janeiro and Belo Horizonte #12;MC's Space Business Involved with aerospace business more than 40 years, covering civil/commercial space business, defense related space business and defense

  12. Managing Abnormal Operation through Process Integration and Cogeneration Systems

    E-Print Network [OSTI]

    Kamrava, Serveh

    2014-08-05T23:59:59.000Z

    & Webster Company, Linde company method. *“Part of this chapter is reprinted with permission from “Managing abnormal operation through process integration and cogeneration systems” by Serveh... (75% for ethane to 28% for hydrogenated gasoline). In Linde method ethylene and propylene is produced from ethane to naphta hydrocarbons by thermal cracking method. Ethylene efficiency is different for different feedstock. For gasoline, naphta...

  13. Drishti: An Integrated Navigation System for Visually Impaired and Disabled

    E-Print Network [OSTI]

    Helal, Abdelsalam

    Drishti: An Integrated Navigation System for Visually Impaired and Disabled This research was supported by Microsoft Research under grant number 4514203-12. Abdelsalam (Sumi) Helal Computer sedwin@cise.ufl.edu Balaji Ramachandran Geomatics Program, Civil Engineering, University of Florida

  14. An Environmental Monitoring System with Integrated Wired and Wireless Sensors

    E-Print Network [OSTI]

    Huang, Yan

    environmental monitoring cyber infrastruc- ture that features (1) soil moisture monitoring with flexible spatial Environmental Observatory (TEO) infrastructure [9] for long-term operation. The new WSN-based soil moistureAn Environmental Monitoring System with Integrated Wired and Wireless Sensors Jue Yang, Chengyang

  15. Integration of Real-Time Data Into Building Automation Systems

    SciTech Connect (OSTI)

    Mark J. Stunder; Perry Sebastian; Brenda A. Chube; Michael D. Koontz

    2003-04-16T23:59:59.000Z

    The project goal was to investigate the possibility of using predictive real-time information from the Internet as an input to building management system algorithms. The objectives were to identify the types of information most valuable to commercial and residential building owners, managers, and system designers. To comprehensively investigate and document currently available electronic real-time information suitable for use in building management systems. Verify the reliability of the information and recommend accreditation methods for data and providers. Assess methodologies to automatically retrieve and utilize the information. Characterize equipment required to implement automated integration. Demonstrate the feasibility and benefits of using the information in building management systems. Identify evolutionary control strategies.

  16. Integral collector storage system with heat exchange apparatus

    DOE Patents [OSTI]

    Rhodes, Richard O.

    2004-04-20T23:59:59.000Z

    The present invention relates to an integral solar energy collector storage systems. Generally, an integral collector storage system includes a tank system, a plurality of heat exchange tubes with at least some of the heat exchange tubes arranged within the tank system, a first glazing layer positioned over the tank system and a base plate positioned under the tank system. In one aspect of the invention, the tank system, the first glazing layer an the base plate each include protrusions and a clip is provided to hold the layers together. In another aspect of the invention, the first glazing layer and the base plate are ribbed to provide structural support. This arrangement is particularly useful when these components are formed from plastic. In yet another aspect of the invention, the tank system has a plurality of interconnected tank chambers formed from tubes. In this aspect, a supply header pipe and a fluid return header pipe are provided at a first end of the tank system. The heat exchange tubes have inlets coupled to the supply header pipe and outlets coupled to the return header pipe. With this arrangement, the heat exchange tubes may be inserted into the tank chambers from the first end of the tank system.

  17. Parallel and Distributed Systems Speaker: Dick Epema

    E-Print Network [OSTI]

    Kuzmanov, Georgi

    systems Online Social Netw. #12;3 M.Sc. Thesis Projects: The Supervision · We help you excel, without is international · We often organize the top international conferences in our field #12;4 M.Sc. Thesis Projects concepts and show that they work · For examples of previous MSc projects see the theses on the PDS website

  18. CSE 513: Distributed Systems (Fault-tolerance)

    E-Print Network [OSTI]

    Cao, Guohong

    fails to operate correctly, nothing catastrophic happens; e.g., in nuclear power plans at all servers in the same order. 8 The Two-Army Problem · Without failure, agreement is trivial, but agreement in faulty systems is much harder. ­ Agreement is needed in electing a coordinator, deciding

  19. 1998 interim 242-A Evaporator tank system integrity assessment report

    SciTech Connect (OSTI)

    Jensen, C.E.

    1998-07-02T23:59:59.000Z

    This Integrity Assessment Report (IAR) is prepared by Fluor Daniel Northwest (FDNW) under contract to Lockheed-Martin Hanford Company (LMHC) for Waste Management Hanford (WMH), the 242-A Evaporator (facility) operations contractor for Fluor Daniel Hanford, and the US Department of Energy, the system owner. The contract specifies that FDNW perform an interim (5 year) integrity assessment of the facility and prepare a written IAR in accordance with Washington Administrative Code (WAC) 173-303-640. The WAC 173-303 defines a treatment, storage, or disposal (TSD) facility tank system as the ``dangerous waste storage or treatment tank and its ancillary equipment and containment.`` This integrity assessment evaluates the two tank systems at the facility: the evaporator vessel, C-A-1 (also called the vapor-liquid separator), and the condensate collection tank, TK-C-100. This IAR evaluates the 242-A facility tank systems up to, but not including, the last valve or flanged connection inside the facility perimeter. The initial integrity assessment performed on the facility evaluated certain subsystems not directly in contact with dangerous waste, such as the steam condensate and used raw water subsystems, to provide technical information. These subsystems were not evaluated in this IAR. The last major upgrade to the facility was project B-534. The facility modifications, as a result of project B-534, were evaluated in the 1993 facility interim integrity assessment. Since that time, the following upgrades have occurred in the facility: installation of a process condensate recycle system, and installation of a package steam boiler to provide steam for the facility. The package boiler is not within the scope of the facility TSD.

  20. Integration Schemes for Dissipative Particle Dynamics Simulations: From Softly Interacting Systems Towards Hybrid Models

    E-Print Network [OSTI]

    Ilpo Vattulainen; Mikko Karttunen; Gerhard Besold; J. M. Polson

    2002-11-15T23:59:59.000Z

    We examine the performance of various commonly used integration schemes in dissipative particle dynamics simulations. We consider this issue using three different model systems, which characterize a variety of different conditions often studied in simulations. Specifically we clarify the performance of integration schemes in hybrid models, which combine microscopic and meso-scale descriptions of different particles using both soft and hard interactions. We find that in all three model systems many commonly used integrators may give rise to surprisingly pronounced artifacts in physical observables such as the radial distribution function, the compressibility, and the tracer diffusion coefficient. The artifacts are found to be strongest in systems, where interparticle interactions are soft and predominated by random and dissipative forces, while in systems governed by conservative interactions the artifacts are weaker. Our results suggest that the quality of any integration scheme employed is crucial in all cases where the role of random and dissipative forces is important, including hybrid models where the solvent is described in terms of soft potentials.

  1. Impact of Distributed Wind on Bulk Power System Operations in ISO-NE: Preprint

    SciTech Connect (OSTI)

    Brancucci Martinez-Anido, C.; Hodge, B. M.; Palchak, D.; Miettinen, J.

    2014-09-01T23:59:59.000Z

    The work presented in this paper aims to study the impact of a range of penetration levels of distributed wind on the operation of the electric power system at the transmission level. This paper presents a case study on the power system in Independent System Operator New England. It is analyzed using PLEXOS, a commercial power system simulation tool. The results show that increasing the integration of distributed wind reduces total variable electricity generation costs, coal- and gas-fired electricity generation, electricity imports, and CO2 emissions, and increases wind curtailment. The variability and uncertainty of wind power also increases the start-up and shutdown costs and ramping of most conventional power plants.

  2. DOE-RL Integrated Safety Management System Description

    SciTech Connect (OSTI)

    SHOOP, D.S.

    2000-09-01T23:59:59.000Z

    The purpose of this Integrated Safety Management System Description (ISMSD) is to describe the U.S. Department of Energy (DOE), Richland Operations Office (RL) ISMS as implemented through the RL Integrated Management System (RIMS). This ISMSD does not impose additional requirements but rather provides an overview describing how various parts of the ISMS fit together. Specific requirements for each of the core functions and guiding principles are established in other implementing processes, procedures, and program descriptions that comprise RIMS. RL is organized to conduct work through operating contracts; therefore, it is extremely difficult to provide an adequate ISMS description that only addresses RL functions. Of necessity, this ISMSD contains some information on contractor processes and procedures which then require RL approval or oversight. This ISMSD does not purport to contain a full description of the contractors' ISM System Descriptions.

  3. Greater than the Sum of its Parts; Electricity, Resources, & Building Systems Integration (ERBSI) (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2009-11-01T23:59:59.000Z

    NREL's Electricity, Resources, and Building Systems Integration Center brings together a diverse group of experts performing grid integration and optimization R&D activities.

  4. Verification and validation guidelines for high integrity systems. Volume 1

    SciTech Connect (OSTI)

    Hecht, H.; Hecht, M.; Dinsmore, G.; Hecht, S.; Tang, D. [SoHaR, Inc., Beverly Hills, CA (United States)

    1995-03-01T23:59:59.000Z

    High integrity systems include all protective (safety and mitigation) systems for nuclear power plants, and also systems for which comparable reliability requirements exist in other fields, such as in the process industries, in air traffic control, and in patient monitoring and other medical systems. Verification aims at determining that each stage in the software development completely and correctly implements requirements that were established in a preceding phase, while validation determines that the overall performance of a computer system completely and correctly meets system requirements. Volume I of the report reviews existing classifications for high integrity systems and for the types of errors that may be encountered, and makes recommendations for verification and validation procedures, based on assumptions about the environment in which these procedures will be conducted. The final chapter of Volume I deals with a framework for standards in this field. Volume II contains appendices dealing with specific methodologies for system classification, for dependability evaluation, and for two software tools that can automate otherwise very labor intensive verification and validation activities.

  5. An Agent-Based Test Bed for the Integrated Study of Retail and Wholesale Power System Operations

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    An Agent-Based Test Bed for the Integrated Study of Retail and Wholesale Power System Operations D study of retail and wholesale power markets operating over transmission and distribution networks with smart-grid functionality. The test bed will seam together two existing test beds, the AMES Wholesale

  6. Utilizing Electric Vehicles to Assist Integration of Large Penetrations of Distributed Photovoltaic Generation Capacity

    SciTech Connect (OSTI)

    Tuffner, Francis K.; Chassin, Forrest S.; Kintner-Meyer, Michael CW; Gowri, Krishnan

    2012-11-30T23:59:59.000Z

    Executive Summary Introduction and Motivation This analysis provides the first insights into the leveraging potential of distributed photovoltaic (PV) technologies on rooftop and electric vehicle (EV) charging. Either of the two technologies by themselves - at some high penetrations – may cause some voltage control challenges or overloading problems, respectively. But when combined, there – at least intuitively – could be synergistic effects, whereby one technology mitigates the negative impacts of the other. High penetration of EV charging may overload existing distribution system components, most prominently the secondary transformer. If PV technology is installed at residential premises or anywhere downstream of the secondary transformer, it will provide another electricity source thus, relieving the loading on the transformers. Another synergetic or mitigating effect could be envisioned when high PV penetration reverts the power flow upward in the distribution system (from the homes upstream into the distribution system). Protection schemes may then no longer work and voltage violation (exceeding the voltage upper limited of the ANSI voltage range) may occur. In this particular situation, EV charging could absorb the electricity from the PV, such that the reversal of power flow can be reduced or alleviated. Given these potential mutual synergistic behaviors of PV and EV technologies, this project attempted to quantify the benefits of combining the two technologies. Furthermore, of interest was how advanced EV control strategies may influence the outcome of the synergy between EV charging and distributed PV installations. Particularly, Californian utility companies with high penetration of the distributed PV technology, who have experienced voltage control problems, are interested how intelligent EV charging could support or affect the voltage control

  7. On the Equivalence of Distributed Systems with Queries and Communication$

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    On the Equivalence of Distributed Systems with Queries and Communication$ Serge Abiteboula , Balder a common goal, such as eval- uating some query. We study the equivalence of such systems. We model for performing tasks such as sending, receiving and querying data. As our model is quite general, the equivalence

  8. Literature Review on Underfloor Air Distribution (UFAD) Systems

    E-Print Network [OSTI]

    Im, P.; Cho, S.; Haberl, J. S.

    2006-01-10T23:59:59.000Z

    ) ..................................................... 6 3.5. Task Ventilation Systems ................................................................................. 7 3.6. Recommendations from Experiences.............................................................. 8 IV. SUMMARY... transactions and journal papers are main sources about the UFAD systems. (More than 100 papers found) Elsevier Literature Search Engine: Keyword: Displacement Ventilation (26 papers found) Keyword: UnderFloor Air Distribution (2 papers found) Center...

  9. Towards a Discipline of Geospatial Distributed Event Based Systems

    E-Print Network [OSTI]

    Heaton, Thomas H.

    Towards a Discipline of Geospatial Distributed Event Based Systems Annie Liu Computer Science, Caltech 1200 E California Blvd Pasadena, CA 91125, USA mani@cms.caltech.edu ABSTRACT A geospatial system is one in which the state space in- cludes one, two or three-dimensional space and time. A geospatial

  10. Century Electric Distribution System Operations Lorenzo Kristov,1

    E-Print Network [OSTI]

    Low, Steven H.

    May 2014 1 21st Century Electric Distribution System Operations Lorenzo Kristov,1 California Independent System Operator Paul De Martini, Caltech Resnick Institute Introduction The electric industry has to provide similar functions for their area of responsibility. Many states also opened retail electricity

  11. Optimal Dispatch of Photovoltaic Inverters in Residential Distribution Systems

    E-Print Network [OSTI]

    Giannakis, Georgios

    method for determining the active- and reactive-power set points for PV inverters in residential systems and ensuring voltage regulation. Binary PV-inverter selection variables and nonlinear power-flow relations--Distribution networks, inverter control, optimal power flow (OPF), photovoltaic (PV) systems, sparsity, voltage

  12. STOCHASTIC CONTROL FOR DISTRIBUTED SYSTEMS WITH APPLICATIONS TO WIRELESS

    E-Print Network [OSTI]

    Huang, Minyi

    communication systems, power control is important at the user level in order to minimize energy requirements, a class of stochastic control problems is for- mulated which includes a fading channel model and a powerSTOCHASTIC CONTROL FOR DISTRIBUTED SYSTEMS WITH APPLICATIONS TO WIRELESS COMMUNICATIONS Minyi Huang

  13. Fuzzy logic based operated device identification in power distribution systems

    E-Print Network [OSTI]

    Manivannan, Karthick Muthu

    2002-01-01T23:59:59.000Z

    by the po~er lines and the other components of distribution systems make them vulnerable to various factors like weather, disturbances caused by animals or human activity, overloading of the system and the aging of or defect in, the components...

  14. Transmission integral analysis of Mössbauer spectra displaying hyperfine parameter distributions with arbitrary profile

    SciTech Connect (OSTI)

    Klencsár, Zoltán, E-mail: z.klencsar@mosswinn.hu [Pitvar u. 11., Budapest 1141 (Hungary)

    2014-10-27T23:59:59.000Z

    Accurate quantitative analysis of Mössbauer spectra displaying thickness effects requires the consideration of the so-called transmission integral when modeling the spectral shape. Whereas this is straightforward when the correct model for the decomposition of the absorber's nuclear resonance absorption cross-section into individual components is a priori known, in the absence of such knowledge and notably in the presence of hyperfine parameter distributions with an unknown profile, the so-called model-independent evaluation methods could be used to fit the spectra. However, the methods available for this purpose were developed for the analysis of spectra for which the thin absorber approximation is valid, and thus they do not take the sample thickness and related effects into account. Consequently, in order to use them for spectra displaying thickness effects, their usage needs to be generalized by combining them with transmission integral fitting. A new algorithm realizing such a generalized version of the Hesse-Rübartsch model-independent evaluation method was developed recently as an integral part of the MossWinn program. In the present work, the working principle of the newly developed algorithm is described in details along with examples illustrating the capabilities of the method for the case of {sup 57}Fe Mössbauer spectroscopy.

  15. Power Systems Engineering Research Center Integration of Storage Devices into Power Systems

    E-Print Network [OSTI]

    Van Veen, Barry D.

    of storage technology have led to wider deployment of storage technologies. In this project we developed energy sources into a power system while improving overall system reliability. Storage also hasPower Systems Engineering Research Center Integration of Storage Devices into Power Systems

  16. HIGH PERFORMANCE INTEGRATION OF DATA PARALLEL FILE SYSTEMS AND COMPUTING

    E-Print Network [OSTI]

    Ph.D. research, he guided me into the research field of distributed systems; his insightful advice of working with him, I learned how to become a professional researcher. I would like to thank my entire for their professional guidance, generous support, and valuable suggestions that were given throughout this research work

  17. A Systems Integration Approach To Lighting Control Systems

    E-Print Network [OSTI]

    Lynch, S.; Renner, R. A.

    2000-01-01T23:59:59.000Z

    Today, the lighting industry is experiencing renewed development and implementation of advanced technologies. One of the most striking advances is the implementation of system solutions in lighting control. This approach promises to contribute...

  18. Modeling Framework and Validation of a Smart Grid and Demand Response System for Wind Power Integration

    SciTech Connect (OSTI)

    Broeer, Torsten; Fuller, Jason C.; Tuffner, Francis K.; Chassin, David P.; Djilali, Ned

    2014-01-31T23:59:59.000Z

    Electricity generation from wind power and other renewable energy sources is increasing, and their variability introduces new challenges to the power system. The emergence of smart grid technologies in recent years has seen a paradigm shift in redefining the electrical system of the future, in which controlled response of the demand side is used to balance fluctuations and intermittencies from the generation side. This paper presents a modeling framework for an integrated electricity system where loads become an additional resource. The agent-based model represents a smart grid power system integrating generators, transmission, distribution, loads and market. The model incorporates generator and load controllers, allowing suppliers and demanders to bid into a Real-Time Pricing (RTP) electricity market. The modeling framework is applied to represent a physical demonstration project conducted on the Olympic Peninsula, Washington, USA, and validation simulations are performed using actual dynamic data. Wind power is then introduced into the power generation mix illustrating the potential of demand response to mitigate the impact of wind power variability, primarily through thermostatically controlled loads. The results also indicate that effective implementation of Demand Response (DR) to assist integration of variable renewable energy resources requires a diversity of loads to ensure functionality of the overall system.

  19. Low-Cost Hydrogen-from-Ethanol: A Distributed Production System...

    Broader source: Energy.gov (indexed) [DOE]

    Low-Cost Hydrogen-from-Ethanol: A Distributed Production System (Presentation) Low-Cost Hydrogen-from-Ethanol: A Distributed Production System (Presentation) Presented at the 2007...

  20. The Integrated Waste Tracking System - A Flexible Waste Management Tool

    SciTech Connect (OSTI)

    Anderson, Robert Stephen

    2001-02-01T23:59:59.000Z

    The US Department of Energy (DOE) Idaho National Engineering and Environmental Laboratory (INEEL) has fully embraced a flexible, computer-based tool to help increase waste management efficiency and integrate multiple operational functions from waste generation through waste disposition while reducing cost. The Integrated Waste Tracking System (IWTS)provides comprehensive information management for containerized waste during generation,storage, treatment, transport, and disposal. The IWTS provides all information necessary for facilities to properly manage and demonstrate regulatory compliance. As a platformindependent, client-server and Web-based inventory and compliance system, the IWTS has proven to be a successful tracking, characterization, compliance, and reporting tool that meets the needs of both operations and management while providing a high level of management flexibility.