National Library of Energy BETA

Sample records for dist no5 pinal

  1. Electrical Dist No5 Pinal Cnty | Open Energy Information

    Open Energy Info (EERE)

    Electrical Dist No5 Pinal Cnty Jump to: navigation, search Name: Electrical Dist No5 Pinal Cnty Place: Arizona Phone Number: (520) 466-7336 Website: www.caidd.com Outage Hotline:...

  2. Electrical Dist No2 Pinal Cnty | Open Energy Information

    Open Energy Info (EERE)

    No2 Pinal Cnty Jump to: navigation, search Name: Electrical Dist No2 Pinal Cnty Place: Arizona Phone Number: (800) 259-1306 Website: ed2.com Outage Hotline: 800-668-8079...

  3. Electrical Dist No3 Pinal Cnty | Open Energy Information

    Open Energy Info (EERE)

    No3 Pinal Cnty Jump to: navigation, search Name: Electrical Dist No3 Pinal Cnty Abbreviation: ED3 Place: Arizona Phone Number: (520) 424-9021 Website: www.ed3online.org Outage...

  4. Electrical Dist No6 Pinal Cnty | Open Energy Information

    Open Energy Info (EERE)

    No6 Pinal Cnty Jump to: navigation, search Name: Electrical Dist No6 Pinal Cnty Place: Arizona Phone Number: (480) 987-3461 Website: ed-6pinalcounty.com Outage Hotline: (480)...

  5. Electrical Dist No4 Pinal Cnty | Open Energy Information

    Open Energy Info (EERE)

    No4 Pinal Cnty Jump to: navigation, search Name: Electrical Dist No4 Pinal Cnty Place: Arizona Phone Number: (520) 466-7336 Website: www.caidd.com Outage Hotline: (520) 510-9311...

  6. Trinity Public Utilities Dist | Open Energy Information

    Open Energy Info (EERE)

    Public Utilities Dist Jump to: navigation, search Name: Trinity Public Utilities Dist Place: California Website: trinitypud.com Outage Hotline: (530) 623-5536 References: EIA Form...

  7. Hohokam Irr & Drain Dist | Open Energy Information

    Open Energy Info (EERE)

    Hohokam Irr & Drain Dist Jump to: navigation, search Name: Hohokam Irr & Drain Dist Place: Arizona Phone Number: (520) 723-7751 Website: hohokamthepowerofchoice.com Outage...

  8. Kings River Conservation Dist | Open Energy Information

    Open Energy Info (EERE)

    Kings River Conservation Dist Jump to: navigation, search Name: Kings River Conservation Dist Place: California Phone Number: 559-237-5567 Website: www.krcd.org Facebook: https:...

  9. Kennebunk Light & Power Dist | Open Energy Information

    Open Energy Info (EERE)

    Kennebunk Light & Power Dist Jump to: navigation, search Name: Kennebunk Light & Power Dist Place: Maine Phone Number: (207) 985-3311 weekdays 7am - 5pm Website: klpd.org...

  10. Roosevelt Public Power Dist | Open Energy Information

    Open Energy Info (EERE)

    Public Power Dist Place: Nebraska Phone Number: 308-635-2424 Website: rooseveltppd.com Facebook: https:www.facebook.compagesRoosevelt-Public-Power-District1389888067908873...

  11. Southwest Public Power Dist | Open Energy Information

    Open Energy Info (EERE)

    Public Power Dist Place: Nebraska Phone Number: (308)285-3295 Website: www.swppd.com Twitter: @SWPPD Facebook: https:www.facebook.comSWPPD Outage Hotline: (800)379-7977...

  12. Utilities Dist-Western IN REMC | Open Energy Information

    Open Energy Info (EERE)

    Utilities Dist-Western IN REMC Jump to: navigation, search Name: Utilities Dist-Western IN REMC Place: Indiana References: EIA Form EIA-861 Final Data File for 2010 - File1a1...

  13. Central Nebraska Pub P&I Dist | Open Energy Information

    Open Energy Info (EERE)

    Pub P&I Dist Jump to: navigation, search Name: Central Nebraska Pub P&I Dist Place: Nebraska Phone Number: 308.995.8601 Website: www.nppd.com Twitter: @nppdnews Facebook: https:...

  14. Van Buren Light & Power Dist | Open Energy Information

    Open Energy Info (EERE)

    Van Buren Light & Power Dist Jump to: navigation, search Name: Van Buren Light & Power Dist Place: Maine Phone Number: (207) 868-3321 Website: www.cmpco.comSuppliersAndPart Outage...

  15. Polk County Rural Pub Pwr Dist | Open Energy Information

    Open Energy Info (EERE)

    Polk County Rural Pub Pwr Dist Jump to: navigation, search Name: Polk County Rural Pub Pwr Dist Place: Nebraska Phone Number: (888) 242-5265 Website: www.pcrppd.com Outage...

  16. Maricopa County M W C Dist | Open Energy Information

    Open Energy Info (EERE)

    M W C Dist Jump to: navigation, search Name: Maricopa County M W C Dist 1 Place: Arizona References: EIA Form EIA-861 Final Data File for 2010 - File1a1 EIA Form 861 Data...

  17. Electrical Dist No7 Maricopa | Open Energy Information

    Open Energy Info (EERE)

    Electrical Dist No7 Maricopa Jump to: navigation, search Name: Electrical Dist No7 Maricopa Place: Arizona Phone Number: 623-935-6253 Outage Hotline: 623-935-6253 References: EIA...

  18. EM_newsletter_IssueNo5.indd

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Issue No. 5 * September 25, 2009 In This Issue  Idaho's IWTU Rises ....................1  ETEC Looks Back in Time ..........1  In Brief .........................................1  People ..........................................8 - IN BRIEF - continued on page 7 continued on page 5 continued on page 2 With the Bubble Off, Idaho Plant Rises Fast On a plateau in the central part of the U.S. Department of Energy's Idaho Site, hundreds of construction workers are swarming over the

  19. Wellton-Mohawk Irr & Drain Dist | Open Energy Information

    Open Energy Info (EERE)

    & Drain Dist Place: Arizona Phone Number: (928) 785-3351 Website: www.wmidd.orgpower.html Outage Hotline: (928) 785-3351 References: EIA Form EIA-861 Final Data File for 2010 -...

  20. Lessons Learned: Peer Exchange Calls -- No. 5 | Department of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    5 Lessons Learned: Peer Exchange Calls -- No. 5 Better Buildings Residential Network Lessons Learned: Peer Exchange Calls, No. 5. PDF icon Lessons Learned: Peer Exchange Calls -- ...

  1. McMullen Valley Water C&D Dist | Open Energy Information

    Open Energy Info (EERE)

    McMullen Valley Water C&D Dist Jump to: navigation, search Name: McMullen Valley Water C&D Dist Place: Arizona Phone Number: 99-928-859-3647 Website: www.harcuvarco.com Outage...

  2. Elec District No. 5 Maricopa C | Open Energy Information

    Open Energy Info (EERE)

    District No. 5 Maricopa C Jump to: navigation, search Name: Elec District No. 5 Maricopa C Place: Arizona Phone Number: (480) 610-8741 Outage Hotline: (480) 610-8741 References:...

  3. Overton Power District No 5 | Open Energy Information

    Open Energy Info (EERE)

    Overton Power District No 5 Jump to: navigation, search Name: Overton Power District No 5 Place: Nevada Phone Number: (702) 397-2512 Website: ebill.opd5.comoscp Twitter: @OPD5...

  4. Improvement of tap holes at Wakayama No. 5 blast furnace

    SciTech Connect (OSTI)

    Yamashita, M.; Kashiwada, M.; Shibuta, H.

    1995-12-01

    The service life of blast furnaces, as the result of various improvement measures, has been extended from the conventional 5 to 7 years to 15 to 20 years. Wakayama No. 5 blast furnace adopted SiC bricks. Though SiC brick excelled in strength and durability, it has raised problems such as tap hole inside temperature lowering attributable to its high thermal conductivity, insufficient mud burning and gas blow-out. Nevertheless, various countermeasures described within have been taken against such problems, and as the result it has now become possible to maintain tap holes in stable conditions.

  5. No. 5 blast furnace 1995 reline and upgrade

    SciTech Connect (OSTI)

    Kakascik, T.F. Jr.

    1996-12-31

    The 1995 reline of No. 5 Blast Furnace is an undertaking which has never been approached in previous relines of any blast furnace in the history of Wheeling Pittsburgh Steel Corporation. The scope of the project is such that it represents a radical departure from W.P.S.C.`s traditional methods of ironmaking. The reline of No. 5 Blast Furnace is one of the largest capital improvements performed at W.P.S.C. Blast Furnaces. The improvements made at one single time are taking a furnace from 1960`s technology into the 21st century. With this in mind, employee training was one of the largest parts of the project. Training for the automated stockhouse, castfloor, new skip drive, new instrumentation, new castfloor equipment, hydraulics and overall furnace operation were an absolute necessity. The reline has laid the ground work to give the Corporation an efficient, higher productive, modern Blast Furnace which will place W.P.S.C. in the world class category in ironmaking well into the 21st century.

  6. EA-325 Emera Energy Services Subsidary No. 5 LLC | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    5 Emera Energy Services Subsidary No. 5 LLC EA-325 Emera Energy Services Subsidary No. 5 LLC Order authorizing Emera Energy Services Subsidary No. 5 LLC to export electric energy to Canada PDF icon EA-325 Emera Energy Services Subsidary No. 5 LLC More Documents & Publications EA-323 Emera Energy Services Subsidary No. 3 LLC EA-321 Emera Energy Services Subsidary No. 1 LLC EA-322 Emera Energy Services Subsidary No. 2

  7. Altos Hornos de Mexico blast furnace No. 5 certification in ISO-9002 standard

    SciTech Connect (OSTI)

    Gamez, O.; Liceaga, F.; Arredondo, J.

    1997-12-31

    Altos Hornos de Mexico`s Blast Furnace No. 5, as a means to improve its product quality, sought and obtained the certification of its quality system based on the international standard ISO-9002. The certification was obtained under this quality standard in Dec. 1995 and has successfully been maintained after two continuance audits. For blast furnace No. 5 (BF5) the benefits are reflected by a reduction in the hot metal silicon content variability, a decrease in fuel consumption and a higher productivity. Benefits were also obtained in the working environment where the personnel became more highly motivated, procedures were carried out to completion and the quality records were filled correctly.

  8. Amped Up! Volume 1, No. 5: EERE Innovation on the Road Through Paris |

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Department of Energy 5: EERE Innovation on the Road Through Paris Amped Up! Volume 1, No. 5: EERE Innovation on the Road Through Paris Clean Energy Technologies: Wind Clean Energy Technologies: Wind Energy Department investments in new wind turbine technologies and performance are increasing America's reliance on wind power to provide safe, clean, domestic energy. Clean Energy Technologies: Solar Clean Energy Technologies: Solar Solar energy innovations at the Energy Department have

  9. AMERICAN ELECTRIC POWER'S CONESVILLE POWER PLANT UNIT NO.5 CO2 CAPTURE RETROFIT STUDY

    SciTech Connect (OSTI)

    Carl R. Bozzuto; Nsakala ya Nsakala; Gregory N. Liljedahl; Mark Palkes; John L. Marion

    2001-06-30

    ALSTOM Power Inc.'s Power Plant Laboratories (ALSTOM) has teamed with American Electric Power (AEP), ABB Lummus Global Inc. (ABB), the US Department of Energy National Energy Technology Laboratory (DOE NETL), and the Ohio Coal Development Office (OCDO) to conduct a comprehensive study evaluating the technical feasibility and economics of alternate CO{sub 2} capture and sequestration technologies applied to an existing US coal-fired electric generation power plant. The motivation for this study was to provide input to potential US electric utility actions concerning GHG emissions reduction. If the US decides to reduce CO{sub 2} emissions, action would need to be taken to address existing power plants. Although fuel switching from coal to natural gas may be one scenario, it will not necessarily be a sufficient measure and some form of CO{sub 2} capture for use or disposal may also be required. The output of this CO{sub 2} capture study will enhance the public's understanding of control options and influence decisions and actions by government, regulators, and power plant owners in considering the costs of reducing greenhouse gas CO{sub 2} emissions. The total work breakdown structure is encompassed within three major reports, namely: (1) Literature Survey, (2) AEP's Conesville Unit No.5 Retrofit Study, and (3) Bench-Scale Testing and CFD Evaluation. The report on the literature survey results was issued earlier by Bozzuto, et al. (2000). Reports entitled ''AEP's Conesville Unit No.5 Retrofit Study'' and ''Bench-Scale Testing and CFD Evaluation'' are provided as companion volumes, denoted Volumes I and II, respectively, of the final report. The work performed, results obtained, and conclusions and recommendations derived therefrom are summarized.

  10. DOE/EV-0005/29 ORNL-5734 Dist. Category UC-70 Contract No. W-7405-eng-26

    Office of Legacy Management (LM)

    9 ORNL-5734 Dist. Category UC-70 Contract No. W-7405-eng-26 Health and Safety Research Division RADIOLOGICAL SURVEY OF THE FORMER KELLEX RESEARCH FACILITY, JERSEY CITY, NEW JERSEY B. A. Berven W. D. Cottrell H. W. Dickson R. W. Doane W. A. Goldsmith F. F. Haywood W. M. Johnson M. T. Ryan W. H. Shinpaugh Worked performed as part of the Remedial Action Survey and Certification Activities Date Published: February 1982 OAK RIDGE NATIONAL LABORATORY operated by UNION'CARBIDE CORPORATION for the

  11. Cliffs Minerals, Inc. Eastern Gas Shales Project, Ohio No. 5 well - Lorain County. Phase II report. Preliminary laboratory results

    SciTech Connect (OSTI)

    1980-04-01

    The US Department of Energy is funding a research and development program entitled the Eastern Gas Shales Project designed to increase commercial production of natural gas in the eastern United States from Middle and Upper Devonian Shales. The program's objectives are as follows: (1) to evaluate recoverable reserves of gas contained in the shales; (2) to enhanced recovery technology for production from shale gas reservoirs; and (3) to stimulate interest among commercial gas suppliers in the concept of producing large quantities of gas from low-yield, shallow Devonian Shale wells. The EGSP-Ohio No. 5 well was cored under a cooperative cost-sharing agreement between the Department of Energy (METC) and Columbia Gas Transmission Corporation. Detailed characterization of the core was performed at the Eastern Gas Shale Project's Core Laboratory. At the well site, suites of wet and dry hole geophysical logs were run. Characterization work performed at the Laboratory included photographic logs, lithologic logs, fracture logs, measurements of core color variation, and stratigraphic interpretation of the cored intervals. In addition samples were tested for physical properties by Michigan Technological University. Physical properties data obtained were for: directional ultrasonic velocity; directional tensile strength; strength in point load; and trends of microfractures.

  12. dist_steam.pdf

    Gasoline and Diesel Fuel Update (EIA)

    (toll free) at 1-888-861-0464. For general information about the survey, visit our Web site at http:www.ei a.doe.govemeucbecs. 6. Please use the enclosed self-addre ssed, ...

  13. dist_hot_water.pdf

    Gasoline and Diesel Fuel Update (EIA)

    District Hot Water Usage Form 1999 Commercial Buildings Energy Consumption Survey (CBECS) ... District Hot Water Usage Was district hot water delivered to the building during the ...

  14. Pinal County, Arizona: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    Chuichu, Arizona Coolidge, Arizona Dudleyville, Arizona Eloy, Arizona Florence, Arizona Gold Camp, Arizona Hayden, Arizona Kearny, Arizona Mammoth, Arizona Maricopa, Arizona...

  15. Lessons Learned: Peer Exchange Calls-- No. 5

    Broader source: Energy.gov [DOE]

    Better Buildings Residential Network Peer Exchange Call Series: Guide for Benchmarking Residential Program Progress with Examples.

  16. Emerald People's Utility Dist | Open Energy Information

    Open Energy Info (EERE)

    Plant Yes Activity Generation Yes Activity Transmission Yes Activity Wholesale Marketing Yes Activity Retail Marketing Yes This article is a stub. You can help OpenEI by...

  17. Clatskanie Peoples Util Dist | Open Energy Information

    Open Energy Info (EERE)

    Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Activity Retail Marketing Yes This article is a stub. You can help OpenEI by...

  18. Cornhusker Public Power Dist | Open Energy Information

    Open Energy Info (EERE)

    Twitter: @cppd Facebook: https:www.facebook.comcornhuskerppd Outage Hotline: 1-800-955-2773 References: EIA Form EIA-861 Final Data File for 2010 - File1a1 Energy...

  19. Reedy Creek Improvement Dist | Open Energy Information

    Open Energy Info (EERE)

    Generation Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes This article is a stub. You can help OpenEI by expanding it. Utility...

  20. HEP-v2-for-dist

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Case S tudy: C on.nuing S tudies o f P lasma B ased Accelerators ( mp113) * PI: W. B. Mori (UCLA) * Presenter: F. S. Tsung (UCLA) Users: W. An, A. Davidson, V. K. Decyk, (UCLA), J. Vieira, L. Silva (IST), W. Lu (UCLA/ Tsinghua) F. S. Tsung, HEP Workshop HEP R equirements: Con.nuing S tudies o f P lasma B ased A ccelerators ( mp113) (PI: W . B . M ori, P resenter: F . S . T sung) An alternate scheme to accelerate particles using plasmas is the Plasma WakeField Accelerator (PWFA) concept where a

  1. Amped Up! Vol. 1, No. 5 September/October 2015

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    5 September/October 2015 A Message from Dave............................................ 3 COP 21 and the Road Through Paris ................. 4 Interview with Jonathan Elkind .......................... 5 Advancing Clean Energy Technologies ............ 6 Solar ........................................................................ 6 Wind ....................................................................... 7 Efficiency ............................................................... 8

  2. Federal Fleet Files, FEMP, Vol. 2, No. 5 - March 2010

    SciTech Connect (OSTI)

    2010-03-02

    March 2010 update from the FEMP Federal Fleet Program that outlines vehicle, alternative fuel, infrastructure, and management strategy updates to Federal agencies.

  3. Amped Up! - Volume 1, No. 5 Fall 2015

    SciTech Connect (OSTI)

    2015-10-01

    Amped Up! is a bimonthly newsletter that highlights the initiatives, events, and technologies in the Office of Energy Efficiency and Renewable Energy that influence change.

  4. Geothermal Progress Monitor report No. 5. Progress report, June 1981

    SciTech Connect (OSTI)

    Not Available

    1981-01-01

    Updated information is presented on activities and progress in the areas of electric power plants, direct heat applications, deep well drilling, leasing of federal lands, legislative and regulatory actions, research and development, and others. Special attention is given in this report to 1980 highlights, particularly in the areas of electric and direct heat uses, drilling, and the Federal lands leasing program. This report also includes a summary of the DOE FY 1982 geothermal budget request to Congress.

  5. QER Public Meeting No. 5 Written Comments of SMUD

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    SUMMARY SMUD is a political subdivision of the state of California formed pursuant to the Municipal Utility District Act (California Public Utility Code 811501 et seq.) to ...

  6. Northwest Rural Pub Pwr Dist | Open Energy Information

    Open Energy Info (EERE)

    Data Utility Id 13805 Utility Location Yes Ownership P NERC Location WECC NERC MRO Yes RTO SPP Yes Activity Distribution Yes This article is a stub. You can help OpenEI by...

  7. South Central Public Pwr Dist | Open Energy Information

    Open Energy Info (EERE)

    Data Utility Id 17548 Utility Location Yes Ownership P NERC Location MRO NERC MRO Yes RTO SPP Yes Activity Distribution Yes Activity Retail Marketing Yes This article is a stub....

  8. Seward County Rrl Pub Pwr Dist | Open Energy Information

    Open Energy Info (EERE)

    Data Utility Id 16954 Utility Location Yes Ownership P NERC Location SPP NERC SPP Yes RTO SPP Yes Activity Distribution Yes This article is a stub. You can help OpenEI by...

  9. North Central Public Pwr Dist | Open Energy Information

    Open Energy Info (EERE)

    Data Utility Id 13698 Utility Location Yes Ownership P NERC Location MRO NERC MRO Yes RTO SPP Yes Activity Distribution Yes This article is a stub. You can help OpenEI by...

  10. Lincoln County Power Dist No 1 | Open Energy Information

    Open Energy Info (EERE)

    Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Activity Retail Marketing Yes This article is a stub. You can help OpenEI by...

  11. Burt County Public Power Dist | Open Energy Information

    Open Energy Info (EERE)

    NERC Location MRO Activity Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes This article is a stub. You can help OpenEI by expanding it. Utility Rate...

  12. Clay Central Everly School Dist Wind Farm | Open Energy Information

    Open Energy Info (EERE)

    Everly School District Energy Purchaser Clay CentralEverly School District Location IA Coordinates 43.1392, -95.2644 Show Map Loading map... "minzoom":false,"mappingservi...

  13. East Bay Municipal Util Dist | Open Energy Information

    Open Energy Info (EERE)

    WECC NERC WECC Yes Operates Generating Plant Yes Activity Generation Yes Activity Wholesale Marketing Yes Alt Fuel Vehicle Yes Alt Fuel Vehicle2 Yes This article is a stub. You...

  14. Electrical Dist No8 Maricopa | Open Energy Information

    Open Energy Info (EERE)

    No8 Maricopa Place: Arizona Phone Number: (602) 254-5908 Website: ieda-az.orgMembers.html Outage Hotline: (602) 254-5908 References: EIA Form EIA-861 Final Data File for 2010 -...

  15. SBOT DIST OF COLUMBIA HEADQUARTERS PROCUREMENT POC Michael Raizen

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Construction 236220 Water and Sewer Line and Related ... Other Heavy and Civil Engineering Construction 237990 ... Deep Sea Freight Transportation 483111 Inland Water Freight ...

  16. EA-1972: Electric District 2 to Saguaro No. 2 Transmission Line...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2: Electric District 2 to Saguaro No. 2 Transmission Line Rebuild; Pinal County, Arizona EA-1972: Electric District 2 to Saguaro No. 2 Transmission Line Rebuild; Pinal County, ...

  17. Title list of documents made publicly available. Volume 17, No. 5

    SciTech Connect (OSTI)

    1995-07-01

    The Title List of Documents Made Publicly Available is a monthly publication. It contains descriptions of the information received and generated by the US Nuclear Regulatory Commission (NRC). This information includes (1) docketed material associated with civilian nuclear power plants and other uses of radioactive materials and (3) nondocketed material received and generated by NRC pertinent to its role as a regulatory agency. As used here, docketed does not refer to Court dockets; it refers to the system by which NRC maintains its regulatory records. This series of documents is indexed by a Personal Author Index, a Corporate Source Index, and a Report Number Index.

  18. Federal Fleet Files, FEMP, Vol. 2, No. 5 - March 2010 (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2010-03-01

    March 2010 update from the FEMP Federal Fleet Program that outlines vehicle, alternative fuel, infrastructure, and management strategy updates to Federal agencies.

  19. Glass Science tutorial lecture No. 5: Historical review of USDOE tank waste management

    SciTech Connect (OSTI)

    McDaniel, E.W.

    1995-02-01

    This is a two day course whose objective is to present an unbiased historical overview of the DOE tank waste activities. World events which impacted the US nuclear program (or vise versa) will be presented. Liquid, mostly tank waste, and sludge are the primary concerns of this course.

  20. Amped Up! Volume 1, No. 5: EERE Innovation on the Road Through Paris

    Broader source: Energy.gov [DOE]

    Amped Up! is a bimonthly newsletter that highlights the initiatives, events, and technologies in the Office of Energy Efficiency and Renewable Energy that influence change.

  1. 1,"Salt River Proj Ag I & P Dist",16572,1999,"Coronado","Silver...

    U.S. Energy Information Administration (EIA) Indexed Site

    ... Valley Authority",18642,1999,"Tap to Hamilton","(Section F)",161,"WF",1,0,"A4",1 774,"Tennessee Valley Authority",18642,1999,"Tap to Hamilton","(Section F)",161,"WP",8,0,"A4",1 ...

  2. Microsoft Word - CX-AlveyDistWoodPoles_FY13_WEB.docx

    Broader source: Energy.gov (indexed) [DOE]

    engineered organisms, synthetic biology, governmentally designated noxious weeds, or invasive species, unless the proposed activity would be contained or confined in a manner...

  3. Pyrolysis and gasification of coal at high temperatures. Quarterly progress report No. 5, September 15, 1988--December 15, 1988

    SciTech Connect (OSTI)

    Zygourakis, K.

    1988-12-31

    Coals of different ranks will be pyrolyzed in a microscope hot-stage reactor using inert and reacting atmospheres. The macropore structure of the produced chars will be characterized using video microscopy and digital image processing techniques to obtain pore size distributions. Comparative studies will quantify the effect of pyrolysis conditions (heating rates, final heat treatment temperatures, particle size and inert or reacting atmosphere) on the pore structure of the devolatilized chars. The devolatilized chars will be gasified in the regime of strong intraparticle diffusional limitations using O{sub 2}/N{sub 2} and O{sub 2}/H{sub 2}O/N{sub 2}2 mixtures. Constant temperature and programmed-temperature experiments in a TGA will be used for these studies. Additional gasification experiments performed in the hot-stage reactor will be videotaped and selected images will be analyzed to obtain quantitative data on particle shrinkage and fragmentation. Discrete mathematical models will be developed and validated using the experimental gasification data.

  4. Technology development for iron Fischer-Tropsch catalysis. Quarterly technical progress report No. 5, October 1, 1995--December 31, 1995

    SciTech Connect (OSTI)

    Davis, B.H.

    1996-01-19

    The objective of this research project is to develop the technology for the production of physically robust iron-based Fischer-Tropsch catalysts that have suitable activity, selectivity and stability to be used in the slurry phase synthesis reactor development. The catalysts that are developed shall be suitable for testing in the Advanced Fuels Development Facility at LaPorte, Texas, to produce either low- or high-alpha product distributions. Previous work by the offeror has produced a catalyst formulation that is 1.5 times as active as the ``standard-catalyst`` developed by German workers for slurry phase synthesis. The proposed work will optimize the catalyst composition and pretreatment operation for this low-alpha catalyst. In parallel, work will be conducted to design a high-alpha iron catalyst this is suitable for slurry phase synthesis. Studies will be conducted to define the chemical phases present at various stages of the pretreatment and synthesis stages and to define the course of these changes. The oxidation/reduction cycles that are anticipated to occur in large, commercial reactors will be studied at the laboratory scale. Catalyst performance will be determined for catalysts synthesized in this program for activity, selectivity and aging characteristics. The research is divided into four major topical areas: (a) catalyst preparation and characterization, (b) product characterization, (c) reactor operations, and (d) data assessment. Accomplishments to date are described.

  5. Co-firing high sulfur coal with refuse derived fuels. Technical progress report No. 5, [October--December 1995

    SciTech Connect (OSTI)

    Pan, Wei-Ping; Riley, J.T.; Lloyd, W.G.

    1995-11-30

    Studies involving the tubular furnace are in the process of identifying the ideal experimental coal-to-refuse derived fuel(RDF) ratio for use in the AFBC system. A series of experiments with this furnace has been performed to determine the possible chemical pathway for formation of chlorinated organic compounds during the combustion of various RDF sources. Phenol and chlorine appear to be likely reactants necessary for the formation of these compounds. The main goal of these experiment is to determine the exact experimental conditions for the formation of chlorinated organic compounds, as well as methods to inhibit their development. Work on the fluidized bed combustor has involved five combustion runs, in which a combustion efficiency of greater than 96% and with a consistent CO{sub 2} concentration of approximately 13% was obtained. Modifications responsible for these improvements include the addition of the underbed fuel feed system and revision of the flue gas sampling system. New methods of determining combustion efficiency and percentage of SO{sub 2} capture using TG techniques to analyze combustion products are being developed. The current outlook using this TGA/FTIR method is very promising, since previously obscured reactions are being studied. the analysis of combustion products is revealing a more complete picture of the combustion process within the AFBC system.

  6. Research on the HYLIFE liquid-first-wall concept for future laser-fusion reactors. Final report No. 5

    SciTech Connect (OSTI)

    Hoffman, M.A.

    1980-09-01

    It has been proposed to protect the structural walls of a future laser fusion reactor with a curtain or fluid-wall of liquid lithium jets. As part of the investigation of this concept, experiments have been performed on planar sheet water jets issuing vertically downward from slit nozzles. The nozzles were subjected to transverse forced harmonic excitation to simulate the vibrational environment of the laser fusion reactor, and experiments were run at both 1 atm and at lower ambient pressures. Linear temporal stability theory is shown to predict the onset of the unstable regime and the initial spatial growth rates quite well for the cases where the amplitudes of the nozzle vibration are not too large and the waveform is nearly sinusoidal. In addition, both the linear theory and a simplified trajectory theory are shown to predict the initial wave envelope amplitudes very well. For larger amplitude nozzle excitation, the waveform becomes highly nonlinear and non-sinusoidal and can resemble a sawtooth waveform in some cases; these latter experimental results can only be partially explained by existing theories at the present time.

  7. EA-1972: Electric District 2 to Saguaro No. 2 Transmission Line Rebuild;

    Energy Savers [EERE]

    Pinal County, Arizona | Department of Energy 2: Electric District 2 to Saguaro No. 2 Transmission Line Rebuild; Pinal County, Arizona EA-1972: Electric District 2 to Saguaro No. 2 Transmission Line Rebuild; Pinal County, Arizona SUMMARY Western Area Power Administration prepared an EA that assesses the potential environmental impacts of the proposed rebuild of a 35.6-mile transmission line that Western operates and maintains under an agreement with the Central Arizona Project. Additional

  8. EA-1972: Draft Environmental Assessment | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Draft Environmental Assessment EA-1972: Draft Environmental Assessment Electric District 2 to Saguaro No. 2 Transmission Line Rebuild, Pinal County, Arizona Western Area Power ...

  9. EA-1972: Final Environmental Assessment | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Final Environmental Assessment EA-1972: Final Environmental Assessment Electric District 2 to Saguaro No. 2 Transmission Line Rebuild, Pinal County, Arizona Western Area Power ...

  10. POC-scale testing of an advanced fine coal dewatering equipment/technique. Quarterly technical progress report No. 5, October--December, 1995

    SciTech Connect (OSTI)

    Groppo, J.G.; Parekh, B.K.

    1996-02-01

    Froth flotation technique is an effective and efficient process for recovering of ultra-fine (minus 74{mu}m) clean coal. Economical dewatering of an ultrafine clean coal product to a 20% level moisture will be an important step in successful implementation of the advanced cleaning processes. The main objective of the proposed program is to evaluate a novel surface modification technique, which utilizes the synergistic effect of metal ions-surfactant combination, for dewatering of ultra-fine clean coal on a proof-of-concept scale of 1 to 2 tph. The novel surface modification technique developed at the the University of Kentucky Center for Applied Energy Research will be evaluated using vacuum, centrifuge, and hyperbaric filtration equipment. Dewatering tests will be conducted using the fine clean coal froth produced by the column flotation units at the Powell Mountain Coal Company, Mayflower Preparation Plant in St. Charles, Virginia. The POC-scale studies will be conducted on two different types of clean coal, namely, high sulfur and low sulfur clean coal. Accomplishments for the past quarter are described.

  11. Improvement of storage, handling, and transportability of fine coal. Quarterly technical progress report No. 5, January 1, 1995--March 31, 1995

    SciTech Connect (OSTI)

    1996-08-21

    The Mulled Coal process was developed as a means of overcoming the adverse handling characteristics of wet fine coal without thermal drying. The process involves the addition of a low cost, harmless reagent to wet fine coal using off-the-shelf mixing equipment. Based on laboratory- and bench-scale testing, Mulled Coal can be stored, shipped, and burned without causing any of the plugging, pasting, carryback and freezing problems normally associated with wet coal. The objectives of this project are to demonstrate that: the Mulled Coal process, which has been proven to work on a wide range of wet fine coals at bench scale, will work equally well on a continuous basis, producing consistent quality at a convincing rate of production in a commercial coal preparation plant; the wet product from a fine coal cleaning circuit can be converted to a solid fuel form for ease of handling and cost savings in storage and rail car transportation; and a wet fine coal product thus converted to a solid fuel form, can be stored, shipped, and burned with conventional fuel handling, transportation, and combustion systems. During this reporting period, virtually all of the technical activities and progress was made in the areas of circuit installation and startup operations. Work in these activity areas are described.

  12. Synthesis of 6-Methyl-9-n-propyldibenzothiophene-4-ol. Quarterly technical progress report No. 5, July 28--October 28, 1991

    SciTech Connect (OSTI)

    Not Available

    1991-10-28

    The material presented here has been described to some extent in Status Reports 12, 13, and 14 and covers the progress toward the synthesis of the modified target molecules 9-isopropyl-4-methoxy-6-methyldibenzothiophene (13) and 9-isopropyl-6-methyldibenzothiophene-4-ol (14). It is divided into three parts: (a) Dehydrogenation experiments On tetrahydrodibenzothiophene 12. (b) methoxyl methyl cleavage of 13 to 14 using boron tribromide. (c) isolation and purification of methoxydibenzothiophene 13.

  13. Synthesis of oxygenate products for high volume fuels applications. Quarterly status report No. 5 for the period October through December 1995

    SciTech Connect (OSTI)

    Not Available

    1996-02-15

    A process variables study was carried out with crude DME as feed for the condensation with acetylene to C{sub 2} and higher alcohols. The addition of water to crude DME had a marked effect of promoting selectivity to ethanol, especially at the lower reaction temperatures tested. Experiments designed to reveal the effect of reactor flow rate and temperature demonstrated that lower rates and higher temperatures favored selectivity to propanol and butanol up to a maximum temperature of 460{degrees}C, beyond which selectivity diminished via decomposition reactions. Faster rates and lower temperatures favored selectivity to ethanol. Reactor conditions and feed compositions for optimum target alcohol selectivities have been identified. the overall objective of this project is to develop catalyst and process technology for evaluation as potential routes for the production of high volume fuel oxygenates.

  14. EO 12866 meeting materials from 2/8 - DOE Distrubtion Transformers...

    Office of Environmental Management (EM)

    PDF icon DOE Dist Trans NOPR ComEd Comments Apr 2012.pdf PDF icon DOE Dist Trans NOPR SA Com Ed Comments Jun 2012.pdf PDF icon DOE Dist Trans Prelim Analysis ComEd Comments ...

  15. CX-007141: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Electrical District 4 - Electrical District 5 - Structure ReplacementCX(s) Applied: B4.6Date: 09/01/2011Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  16. CX-007171: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Signal Tap SubstationCX(s) Applied: B4.6Date: 09/09/2010Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  17. CX-007169: Categorical Exclusion Determination

    Office of Energy Efficiency and Renewable Energy (EERE)

    Saguaro-Oracle Vegetation RemovalCX(s) Applied: B1.3Date: 04/07/2011Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  18. Agency's Work Having a Ripple Effect in Community | Department...

    Broader source: Energy.gov (indexed) [DOE]

    Reducing energy costs for families is a natural part of CAHRA's mission of fighting poverty in Pinal County. The agency is administering 2.1 million in Recovery Act funding to ...

  19. CX-004891: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Coolidge-Oracle (Structure Maintenance)CX(s) Applied: B1.3Date: 07/29/2010Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  20. CX-001516: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Energy Efficiency AuditsCX(s) Applied: A9, A11, B5.1Date: 03/31/2010Location(s): Pinal County, ArizonaOffice(s): Energy Efficiency and Renewable Energy, Golden Field Office

  1. CX-004889: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Casa Grande-Empire (Geological Boring)CX(s) Applied: B3.1Date: 08/19/2010Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  2. CX-004888: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Casa Grande-Empire (Double Circuit Upgrade)CX(s) Applied: B4.13Date: 09/15/2010Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  3. CX-007130: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Casa Grande-EmpireCX(s) Applied: B3.1Date: 09/14/2010Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  4. CX-007133: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Casa Grande-Saguaro Structure MaintenanceCX(s) Applied: B1.3Date: 12/16/2010Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  5. CX-004876: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Casa Grande-Empire (Double Circuit Upgrade)CX(s) Applied: B4.13Date: 09/15/2010Location(s): Pinal County, ArizonaOffice(s): Bonneville Power Administration

  6. CX-007132: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Casa Grande-Empire Double Circuit Upgrade AmendmentCX(s) Applied: B4.13Date: 04/28/2011Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  7. CX-007136: Categorical Exclusion Determination

    Office of Energy Efficiency and Renewable Energy (EERE)

    Coolidge-Oracle Pole ReplacementCX(s) Applied: B4.6Date: 11/13/2009Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  8. CX-007168: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Rodgers-Cooolidge Structure MaintenanceCX(s) Applied: B1.3Date: 08/26/2011Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  9. CX-007145: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Empire-Electrical District 5 Double Circuit Upgrade AmendmentCX(s) Applied: B1.3Date: 05/02/2011Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  10. CX-007144: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Empire-Electrical District 5 Double Circuit Upgrade AmendmentCX(s) Applied: B1.3Date: 04/28/2011Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  11. CX-007142: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Electrical District 5 - Saguaro Structure MaintenanceCX(s) Applied: B1.3Date: 02/09/2011Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  12. CX-007167: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Rogers-Coolidge Danger Tree RemovalCX(s) Applied: B1.3Date: 02/18/2010Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  13. Gold Camp, Arizona: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    Hide Map This article is a stub. You can help OpenEI by expanding it. Gold Camp is a census-designated place in Pinal County, Arizona.1 References US Census...

  14. Casa Grande, Arizona: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    Hide Map This article is a stub. You can help OpenEI by expanding it. Casa Grande is a city in Pinal County, Arizona. It falls under Arizona's 1st congressional...

  15. CX-007135: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Coolidge-Oracle Crossarm ReplacementCX(s) Applied: B1.3Date: 07/29/2010Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  16. CO_CODE","PLT_CODE","YEAR","MONTH","BLANK1","BOM_DIST","ORIG_ST","MINE_TYPE","BL

    U.S. Energy Information Administration (EIA) Indexed Site

    0,01,,,,,,07,48,,3,"NG",,4,0,218000,1034,0,0,279.5,,1 050010,3451,90,01,,,,,,07,48,,2,"FO5",,7,9,5000,148000,0.5,0.1,265.6,,1 050010,3452,90,01,,,,,,07,48,,3,"NG",,4,0,1062000,1037,0,0,279.5,,1 050010,3452,90,01,,,,,,07,48,,2,"FO5",,7,9,2900,148000,0.5,0.1,265.6,,1 050010,3453,90,01,,,,,,07,48,,2,"FO5",,7,9,13500,148000,0.5,0.1,265.6,,1 050010,3453,90,01,,,,,,07,48,,3,"NG",,4,0,2469000,1015,0,0,279.5,,1

  17. CO_CODE","PLT_CODE","YEAR","MONTH","BLANK1","BOM_DIST","ORIG_ST","MINE_TYPE","BL

    U.S. Energy Information Administration (EIA) Indexed Site

    1,91,01,,,,,,07,48,,3,"NG",,4,0,1000,1024,0,0,261.7,,1 050010,3452,91,01,,,,,,07,48,,3,"NG",,4,0,1532000,1030,0,0,261.7,,1 050010,3452,91,01,,,,,,07,48,,2,"FO2",,7,9,10000,138000,0.5,0.1,564,,1 050010,3452,91,01,,,,,,07,48,,2,"FO5",,7,9,7000,148000,0.5,0.1,510.8,,1 050010,3453,91,01,,,,,,07,48,,3,"NG",,4,0,2079000,1021,0,0,261.7,,1 050010,3454,91,01,,,,,,07,48,,3,"NG",,4,0,360000,1017,0,0,261.7,,1

  18. CO_CODE","PLT_CODE","YEAR","MONTH","BLANK1","BOM_DIST","ORIG_ST","MINE_TYPE","BL

    U.S. Energy Information Administration (EIA) Indexed Site

    2,92,01,,,,,,07,48,,3,"NG",,4,0,1887000,1041,0,0,260.2,,1 050010,3453,92,01,,,,,,07,48,,3,"NG",,4,0,1248000,1025,0,0,260.2,,1 050010,3453,92,01,,,,,,07,48,,2,"FO5",,7,9,23000,148000,0.5,0.1,290.7,,1 050010,3454,92,01,,,,,,07,48,,3,"NG",,4,0,798000,1021,0,0,260.2,,1 050010,3455,92,01,,,,,,07,48,,3,"NG",,4,0,22000,1012,0,0,260.2,,1 050010,3489,92,01,,,,,,07,48,,3,"NG",,4,0,123000,1025,0,0,260.2,,1

  19. CX-001118: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Emergency Wood Pole Replacement at 59 Structures Located Along the Coolidge-Oracle 115-Kilovolt Transmission LineCX(s) Applied: B4.6Date: 11/13/2009Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  20. CX-007140: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Vegetation Removal and Access Road Maintenance along the existing Electrical District 2-Saguaro #2 115-kV transmission lineCX(s) Applied: B1.3Date: 03/21/2011Location(s): Pinal County, ArizonaOffice(s): Western Area Power Administration-Desert Southwest Region

  1. Soyminas Biodiesel | Open Energy Information

    Open Energy Info (EERE)

    Soyminas Biodiesel Jump to: navigation, search Name: Soyminas Biodiesel Place: DIST. INDUSTRIAL, Brazil Zip: 37980-000 Product: Brazilian biodiesel producer located in Minas...

  2. OTTER3.3

    Energy Science and Technology Software Center (OSTI)

    000482UNIXW00 Automated deduction for first-order logic with equality http://www.mcs.anl.gov/AR/otter/dist33

  3. Will Power Company | Open Energy Information

    Open Energy Info (EERE)

    Place: Kullu Dist., Himachal Pradesh, India Sector: Hydro Product: Kullu-based small hydro project developer. References: Will Power Company1 This article is a stub. You can...

  4. Malana Power Company Ltd MPCL | Open Energy Information

    Open Energy Info (EERE)

    Kullu Dist., Himachal Pradesh, India Sector: Hydro Product: Kullu-based firm formed as a joint venture between SN Power and LNJ Bhilwara Group that owns hydroelectric project....

  5. R M Mohite Textiles Ltd | Open Energy Information

    Open Energy Info (EERE)

    Mohite Textiles Ltd Jump to: navigation, search Name: R. M. Mohite Textiles Ltd. Place: Dist. Kolhapur, Maharashtra, India Zip: 416 112 Sector: Hydro Product: Kolhapur based,...

  6. Notices

    Energy Savers [EERE]

    64 Federal Register / Vol. 78, No. 165 / Monday, August 26, 2013 / Notices where the pipeline route crosses the Gila River. A 2.2-mile segment of the Florence- Kelvin Highway, a Pinal County- maintained roadway, would require realignment as a result of constructing the facility. A 2.1-mile section of the road would be relocated north of its current alignment. The proposed facility would require the relocation of the San Carlos Irrigation Project power line which currently passes though the

  7. Microsoft Word - 13035181 13035182 DVP.docx

    Office of Legacy Management (LM)

    ... X San Juan River about 1500' below dist. Channel 1118 X Seep sump (423426) U, SO4, N as ... MIS-A-039 Chromium Gross Alpha Gross Beta Iron Lead Magnesium X X 5 SW-846 6010 LMM-01 ...

  8. TABLE15.CHP:Corel VENTURA

    Annual Energy Outlook [U.S. Energy Information Administration (EIA)]

    Dist. Commodity IV V Texas La. Texas Gulf Gulf N. La., New U.S. Inland Coast Coast Ark. Mexico Total Rocky Mt. West Coast Total January 1998 Natural Gas Liquids...

  9. Hope Solar | Open Energy Information

    Open Energy Info (EERE)

    Solar Jump to: navigation, search Name: Hope Solar Address: No.6-8 Hope Road Taihu Town Tongzhou Dist Place: Beijing, China Sector: Solar Product: Solar cells and power systems...

  10. Overview of the CPUC's California Solar Initiative and DG Programs

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    ...PUCenergyDistGen 2 DG and Renewables Policies and Programs DG Type Programs System-Side Generation or Utility-Side ... but built on related distributed generation rebate ...

  11. CX-007131: Categorical Exclusion Determination | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1: Categorical Exclusion Determination CX-007131: Categorical Exclusion Determination Casa Grande-Empire Double Circuit Upgrade and Structure Replacement CX(s) Applied: B1.3 Date: 03/08/2011 Location(s): Pinal County, Arizona Office(s): Western Area Power Administration-Desert Southwest Region Western proposes to replace structures and upgrade to a double circuit 230- kilovolt (kV) transmission line on its Casa Grande-Empire 115-kV transmission line, from Thornton Road to its Empire Substation,

  12. RECORD OF CATEGORICAL EXCLUSION DETERMINATION

    Energy Savers [EERE]

    geological boring near 9 structure locations along the existing ED2-ED5 230-kV transmission line located in Pinal County, Arizona RECORD OF CATEGORICAL EXCLUSION DETERMINATION A, Proposed Action: Western proposes to do geologic borings within our right-of-way near structures 21/5,22/5,23/6,25/4,26/5,27/6,28/5,29/5 & 30/4 along the existing ED2-ED5 230-kV transmission line. This project involves accessing each bore hole location with a auger/drill rig and light crew trucks, setting up the

  13. TABLE15.CHP:Corel VENTURA

    Gasoline and Diesel Fuel Update (EIA)

    5. Natural Gas Plant Net Production and Stocks of Petroleum Products by PAD and Refining PAD District I PAD District II Commodity East Appalachian Minn., Wis., Okla., Kans., Coast No. 1 Total Ind., Ill., Ky. N. Dak., S. Dak. Mo. Total Net Production Net Production Stocks Stocks Districts, (Thousand Barrels) PAD District III PAD Dist. PAD Dist. Commodity IV V Texas La. Texas Gulf Gulf N. La., New U.S. Inland Coast Coast Ark. Mexico Total Rocky Mt. West Coast Total January 1998 Natural Gas Liquids

  14. Environmental Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Dist. Category UC-l 1, 13 DE@ 010764 Health & Environmental Research Summary of Accomplishments Prepared by Office of Energy Research /U.S. Department of Energy Washington, D.C. 20585 Reprinted April 1984 Published by Technical Information Center/U.S. Department of Energy The purpose of this brief narrative is to foster an awareness of a publicly funded health and environmental research program chartered nearly forty years ago, of its contributions toward the national goal of safe and

  15. Visioning the 21st Century Electricity Industry: Outcomes and Strategies for America

    Energy Savers [EERE]

    Lauren Azar Senior Advisor to the Secretary U. S. Department of Energy 8 February 2012 Visioning the 21 st Century Electricity Industry: Strategies and Outcomes for America http://teeic.anl.gov/er/transmission/restech/dist/index.cfm We all have "visions," in one form or another: * Corporations call them strategic plans * RTOs ... transmission expansion plans or Order 1000 plans * State PUCs ... integrated resource plans * Employees ... career goals Artist: Paolo Frattesi Artist: Paolo

  16. PUBLIC ADMINISTRATION COLORADO GOLDEN FIELD OFFICE POC Karen Downs

    Energy Savers [EERE]

    PUBLIC ADMINISTRATION COLORADO GOLDEN FIELD OFFICE POC Karen Downs Telephone (720) 356-1269 Email karen.downs@go.doe.gov Police Protection 922120 Administration of Education Programs 923110 International Affairs 928120 DIST OF COLUMBIA HEADQUARTERS PROCUREMENT POC Michael Raizen Telephone (202) 287-1512 Email michael.raizen@hq.doe.gov Police Protection 922120 Administration of Education Programs 923110 Administration of Human Resource Programs (except Education, Public Health, and Veterans'

  17. Requested information regarding remote analytical capabilities

    SciTech Connect (OSTI)

    Steel, R.T.

    1991-09-01

    This document describes a new method for analysis of cyanide in radioactive waste samples from the Hanford Site. The new assay is designed to increase throughput of samples, reduce waste volumes and decrease radiation exposure to analysts. The system is based on the Lachat Micro-Dist{sup TM} microdistillation system. This document contains the reference and methods manual for this kit, and also the specific PNL lab procedures for using this kit. 6 refs., 20 figs. (MHB)

  18. EXHIBIT IV DOE/EV-0003/29 ORNL-5734

    Office of Legacy Management (LM)

    v EXHIBIT IV - DOE/EV-0003/29 ORNL-5734 Radiological Survey of the Former Kellex Research Facility, Jersey City, New Jersey 6. A. Berven H. W. Dickson W. A. Goldsmith W. M. Johnson W. D. Cottrell R. W. Doane F. F. Haywood M. T. Ryan W. H. Shinpaugh DOE/EV-0005/29 ORNL-5734 Dist. Category UC-70 Contract No. W-7405-eng-26 Health and Safety Research Division RADIOLOGICAL SURVEY OF THE FORMER KELLEX RESEARCH FACILITY, JERSEY CITY, NEW JERSEY B. A. Berven W. D. Cottrell H. W. Dickson R. W. Doane W.

  19. C:\My Documents\FORMS\DOE F 4200.40A.cdr

    Energy Savers [EERE]

    FINANCIAL ASSISTANCE ACTIONS DOE F 4200.40A (10-03) (All Other Editions Are Obsolete) U.S. DEPARTMENT OF ENERGY INDIVIDUAL PROCUREMENT ACTION REPORT (IPAR) 11. ZIP CODE 12. CONG DIST. 41. DESCRIPTION OF WORK 5. CONTRACTOR NAME 6. DIVISION 9. CITY 10. COUNTY See Handbook for the Preparation of the Individual Procurement Action Report 39. BUDGET FROM DATE 40. BUDGET TO DATE Original - Contract File Goldenrod - ADP Entry Printed with soy ink on recycled paper ADD/CHANGE/DELETE 1. AWARD BIN 2. MOD

  20. Accomplishnents

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Accomplishnents - of The Oak Ridge Nutiorull Lubomtoly I DOE/ER--0274 DE86 015376 prepared by U.S. Department of Energy Ofice of Energy Research Ofice of Program Analysis Washington, DC 20545 September 1986 DOE/ER-0274 Dist. Category UC-13 DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government Neither the United States Government nor any agency thereof, nor any of their employ- make any warranty, express or implied, or asumes any legal

  1. TPSL

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    TPSL TPSL Description The Cray Third Party Scientific Libraries (TPSL), is a collection of scientific libraries and solvers contaning: MUMPS ParMetis SuperLU, SuperLU_DIST Hypre Scotch Sundials Access The Cray TPSL module is available on the NERSC Cray systems, Cori and Edison. To use: module load cray-tpsl Using TPSL After loading the cray-tpsl module, the compiler wrappers (ftn, cc, CC) will automatically link with the all the included third party libraries. To find out which versions of each

  2. A Distributed Python HPC Framework: ODIN, PyTrilinos, & Seamless

    SciTech Connect (OSTI)

    Grant, Robert

    2015-11-23

    Under this grant, three significant software packages were developed or improved, all with the goal of improving the ease-of-use of HPC libraries. The first component is a Python package, named DistArray (originally named Odin), that provides a high-level interface to distributed array computing. This interface is based on the popular and widely used NumPy package and is integrated with the IPython project for enhanced interactive parallel distributed computing. The second Python package is the Distributed Array Protocol (DAP) that enables separate distributed array libraries to share arrays efficiently without copying or sending messages. If a distributed array library supports the DAP, it is then automatically able to communicate with any other library that also supports the protocol. This protocol allows DistArray to communicate with the Trilinos library via PyTrilinos, which was also enhanced during this project. A third package, PyTrilinos, was extended to support distributed structured arrays (in addition to the unstructured arrays of its original design), allow more flexible distributed arrays (i.e., the restriction to double precision data was lifted), and implement the DAP. DAP support includes both exporting the protocol so that external packages can use distributed Trilinos data structures, and importing the protocol so that PyTrilinos can work with distributed data from external packages.

  3. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

    National Nuclear Security Administration (NNSA)

    9 11. CONTRACT 10 CODE 1PAGE OF PAGES AMENDMENT OF SOLICITATIONMODIFICATION OF CONTRACT 1 I 25 2. AMENDMENTMODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITIONPURCHASE REQ . NO . 5 ...

  4. Fueling the Economy | Argonne National Laboratory

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    : Asphalt and road oil consumption, price, and expenditure estimates, 2014 State Asphalt and road oil a Consumption Prices Expenditures Thousand barrels Trillion Btu Dollars per million Btu Million dollars Alabama 2,484 16.5 15.69 258.6 Alaska 1,859 12.3 16.33 201.4 Arizona 2,454 16.3 14.69 239.1 Arkansas 1,884 12.5 15.29 191.2 California 8,646 57.4 15.97 916.3 Colorado 2,398 15.9 15.57 247.8 Connecticut 1,580 10.5 15.69 164.6 Delaware 424 2.8 15.89 44.7 Dist. of Col. 636 4.2 15.93 67.2 Florida

  5. Table Definitions, Sources, and Explanatory Notes

    Gasoline and Diesel Fuel Update (EIA)

    Residual Fuel Prices by Sales Type Definitions Key Terms Definition Gas Plant Operator Any ... Residual Fuel Oil A general classification for the heavier oils, known as No. 5 and No. 6 ...

  6. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

    National Nuclear Security Administration (NNSA)

    Page 1 of 4 PAGES 2. AMENDMENTMODIFICATION NO. M0538 3. EFFECTIVE DATE See Block 16C 4. REQUISITIONPURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE U.S. ...

  7. CX-010735: Categorical Exclusion Determination

    Broader source: Energy.gov [DOE]

    Grand Coulee-Bell No.5 Dead End Insulator Replacement Project CX(s) Applied: B1.3 Date: 07/19/2013 Location(s): Washington, Washington Offices(s): Bonneville Power Administration

  8. THURSDAY: Deputy Secretary of Energy to Visit Western Area Power Administration Transmission Substation

    Broader source: Energy.gov [DOE]

    Deputy Secretary of Energy Elizabeth Sherwood-Randall will visit the Western Area Power Administration for a ceremony at the Electrical District No. 5 Substation to view progress on the Electrical District 5-to-Palo Verde transmission project.

  9. Microsoft Word - M127 Word.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 3. EFFECTIVE DATE (MDY) See Block 16C 4. REQUISITIONPURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S....

  10. Microsoft Word - SF30_A007 _2_.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    7 3. EFFECTIVE DATE (MDY) See Block 16C 4. REQUISITIONPURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S....

  11. Jefferson Lab's Distributed Data Acquisition

    SciTech Connect (OSTI)

    Trent Allison; Thomas Powers

    2006-05-01

    Jefferson Lab's Continuous Electron Beam Accelerator Facility (CEBAF) occasionally experiences fast intermittent beam instabilities that are difficult to isolate and result in downtime. The Distributed Data Acquisition (Dist DAQ) system is being developed to detect and quickly locate such instabilities. It will consist of multiple Ethernet based data acquisition chassis distributed throughout the seven-eights of a mile CEBAF site. Each chassis will monitor various control system signals that are only available locally and/or monitored by systems with small bandwidths that cannot identify fast transients. The chassis will collect data at rates up to 40 Msps in circular buffers that can be frozen and unrolled after an event trigger. These triggers will be derived from signals such as periodic timers or accelerator faults and be distributed via a custom fiber optic event trigger network. This triggering scheme will allow all the data acquisition chassis to be triggered simultaneously and provide a snapshot of relevant CEBAF control signals. The data will then be automatically analyzed for frequency content and transients to determine if and where instabilities exist.

  12. Voluntary Reporting of Greenhouse Gases Program - Electricity...

    Gasoline and Diesel Fuel Update (EIA)

    Jet Fuel ( Jet A, JP-8) 70.88 kg CO2 MMBtu 9.57 kg CO2 gallon Kerosene 72.31 kg CO2 MMBtu 9.76 kg CO2 gallon Heavy Fuel Oil (No. 5, 6 fuel oil), bunker fuel 78.80 kg CO2 ...

  13. Lessons Learned: Peer Exchange Calls -- No. 4 | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    4 Lessons Learned: Peer Exchange Calls -- No. 4 Better Buildings Residential Network Lessons Learned: Peer Exchange Calls, No. 4. PDF icon Lessons Learned: Peer Exchange Calls -- No. 4 More Documents & Publications Better Buildings Residential Network: Lessons Learned: Peer Exchange Calls Lessons Learned: Peer Exchange Calls -- No. 5 Lessons Learned: Peer Exchange Calls -- No. 3

  14. Comparison of the Epson Expression 1680 flatbed and the Vidar VXR-16 Dosimetry PRO trade mark sign film scanners for use in IMRT dosimetry using Gafchromic and radiographic film

    SciTech Connect (OSTI)

    Wilcox, Ellen; Daskalov, George; Nedialkova, Lucy

    2007-01-15

    Intensity-modulated radiotherapy (IMRT) treatment plan verification is often done using Kodak EDR2 film and a Vidar Dosimetry PRO trade mark sign film digitizer. However, since many hospitals are moving towards a filmless environment, access to a film processor may not be available. Therefore, we have investigated a newly available Gafchromic[reg] EBT film for IMRT dosimetry. Planar IMRT dose distributions are delivered to both EBT and EDR2 film and scanned with the Vidar VXR-16 as well as an Epson Expression 1680 flatbed scanner. The measured dose distributions are then compared to those calculated with a Pinnacle treatment planning system. The IMRT treatments consisted of 7-9 6 MV beams for treatment of prostate, head and neck, and a few other sites. The films were analyzed using FilmQA trade mark sign (3cognition LLC) software. Comparisons between measured and calculated dose distributions are reported as dose difference (DD) (pixels within {+-}5%), distance to agreement (DTA) (3 mm), as well as gamma values ({gamma}) (dose={+-}3%, dist.=2 mm). Using EDR2 with the Vidar scanner is an established technique and agreement between calculated and measured dose distributions was better than 90% in all indices (DD, DTA, and {gamma}). However, agreement with calculations deteriorated reaching the lower 80% for EBT film scans with the Vidar scanner in logarithmic mode. The EBT Vidar scans obtained in linear mode showed an improved agreement to the upper 80% range, but artifacts were still observed across the scan. These artifacts were very distinct in all EBT scans and can be attributed to the way the film is transported through the scanner. In the Epson scanner both films are rigidly immobilized and the light source scans over the film. It was found that the Epson scanner performed equally well with both types of film giving agreement to better than 90% in all indices.

  15. Human jagged polypeptide, encoding nucleic acids and methods of use

    DOE Patents [OSTI]

    Li, Linheng; Hood, Leroy

    2000-01-01

    The present invention provides an isolated polypeptide exhibiting substantially the same amino acid sequence as JAGGED, or an active fragment thereof, provided that the polypeptide does not have the amino acid sequence of SEQ ID NO:5 or SEQ ID NO:6. The invention further provides an isolated nucleic acid molecule containing a nucleotide sequence encoding substantially the same amino acid sequence as JAGGED, or an active fragment thereof, provided that the nucleotide sequence does not encode the amino acid sequence of SEQ ID NO:5 or SEQ ID NO:6. Also provided herein is a method of inhibiting differentiation of hematopoietic progenitor cells by contacting the progenitor cells with an isolated JAGGED polypeptide, or active fragment thereof. The invention additionally provides a method of diagnosing Alagille Syndrome in an individual. The method consists of detecting an Alagille Syndrome disease-associated mutation linked to a JAGGED locus.

  16. Methods of diagnosing alagille syndrome

    DOE Patents [OSTI]

    Li, Linheng; Hood, Leroy; Krantz, Ian D.; Spinner, Nancy B.

    2004-03-09

    The present invention provides an isolated polypeptide exhibiting substantially the same amino acid sequence as JAGGED, or an active fragment thereof, provided that the polypeptide does not have the amino acid sequence of SEQ ID NO:5 or SEQ ID NO:6. The invention further provides an isolated nucleic acid molecule containing a nucleotide sequence encoding substantially the same amino acid sequence as JAGGED, or an active fragment thereof, provided that the nucleotide sequence does not encode the amino acid sequence of SEQ ID NO:5 or SEQ ID NO:6. Also provided herein is a method of inhibiting differentiation of hematopoietic progenitor cells by contacting the progenitor cells with an isolated JAGGED polypeptide, or active fragment thereof. The invention additionally provides a method of diagnosing Alagille Syndrome in an individual. The method consists of detecting an Alagille Syndrome disease-associated mutation linked to a JAGGED locus.

  17. Nondestructive assay (NDA) techniques and procedures

    SciTech Connect (OSTI)

    Not Available

    1994-05-01

    Report No. 4 is precursory to Report No. 5 {open_quotes}Determination of the Quantity and Locations of the Pu Currently Retained in the Cimarron Fuel Plant Systems{close_quotes} which will be presented upon completion of the decontamination of the Cimarron Plutonium Fuel Fabrication Facility. This report presents the Non-Destructive Assay (NDA) procedures which were developed and used by Sequoyah Fuels Corporation (successor to Kerr-McGee Nuclear Corporation) to measure equipment hold-up of plutonium materials for inventory purposes during operation of the plant. These procedures are also used to measure plutonium contamination on the equipment removed from the Material Balance Areas (MBA`s) during final decontamination. Report No. 5 will compare the measurements taken during this final decontamination period to previous inventory hold-up measurements, the date will be statistically analyzed, and a long-term assessment of the performance of the NDA equipment will be described.

  18. Short-Term Energy Outlook - U.S. Energy Information Administration (EIA)

    U.S. Energy Information Administration (EIA) Indexed Site

    2 : Energy Prices Either scripts and active content are not permitted to run or Adobe Flash Player version ${version_major}.${version_minor}.${version_revision} or greater is not installed. Get Adobe Flash Player a Average for all sulfur contents. b Average self-service cash price. c Includes fuel oils No. 4, No. 5, No. 6, and topped crude. - = no data available Notes: Prices are not adjusted for inflation. The approximate break between historical and forecast values is shown with estimates and

  19. C:\My Documents\FORMS\DOE F 4200.41.cdr

    Energy Savers [EERE]

    200.41 (10-03) (All Other Editions Are Obsolete) U.S. DEPARTMENT OF ENERGY INDIVIDUAL PROCUREMENT ACTION REPORT SUPPLEMENT FOR PROCUREMENT AND FINANCIAL ASSISTANCE 4. B&R NO. 5. DOLLARS 6. WORK FOR OTHERS FA See Handbook for the Preparation of the Individual Procurement Action Report Original - Contract File Goldenrod - ADP Entry Printed with soy ink on recycled paper ADD/CHANGE: 1. AWARD BIN 2. MOD NUMBER 3. KIND OF AWARD Change Delete Add

  20. CX-012215: Categorical Exclusion Determination | Department of Energy

    Office of Environmental Management (EM)

    215: Categorical Exclusion Determination CX-012215: Categorical Exclusion Determination Curecanti-Poncha 230-Kilovolt Transmission Line Vegetation Management Under the Uncompahgre/Com Task Letter No. 5-No Name Creek Project CX(s) Applied: B1.3 Date: 05/16/2014 Location(s): Colorado Offices(s): Western Area Power Administration-Rocky Mountain Region Western Area Power Administration (Western) proposes to fund right-of-way (ROW) and off-ROW vegetation restoration treatments along it's

  1. COMPNAME","COMPID","YEAR","PLANTNAME","KIND","CONSTRUC","INSTALLED","MAXCAP","NE

    U.S. Energy Information Administration (EIA) Indexed Site

    EQUIP","TOTCOST","COSTCAP","GROSSEXP","OPERENG","FUEL","COOLANTS","STEXP","STOTH","STTRANS","ELECEXP","MISCST","RENTS","MAINSUP","MAINSTRUC","MAINBOIL","MAINELEC","MAINMISC","TOTPROD","EXPKWH","UNITCL","QUANTCL","AVGHEATCL","ACDELCL","ACBURNCL","ACBTUCL","ACNETGENCL","ABTUNETGCL","UNITGAS","QUANTGAS","AVGHEATGAS","ACDELGAS","ACBURNGAS","ACBTUGAS","ACNETGNGAS","ABTUNETGAS","UNITOIL","QUANTOIL","AVGHEATOIL","ACDELOIL","ACBURNOIL","ACBTUOIL","ACNETGNOIL","ABTUNETOIL" "Tennessee Valley Authority",18642,1999,"Sequoyah","Nuclear","01/01/81",,2441160,2303000,8760,1008,1.8570502e+10,3184031,533636867,2488511062,3025331960,1239,33187938,21080862,86166618,4316783,11925073,0,0,13329621,28360769,0,16330987,1528775,8295886,3650336,7012139,201997849,11,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,"MillionBTU",189924066,0,0,0,0.43,0.04,10230 "Tennessee Valley Authority",18642,1999,"Watts Bar","Nuclear","01/01/96","1/1/1996",1269000,1200000,8208,728,8230350000,1953589,2108999339,4827648621,6938601549,5468,30551823,12179502,38261150,3963151,7056493,0,0,10400580,24553068,0,14243155,2328791,9244870,870737,990214,124091711,15,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,"MillionBTU",84467683,0,0,0,0.43,0.04,10260 "Tennessee Valley Authority",18642,1999,"Johnsonville","Gas Turbine","01/01/75","1/1/1975",1088000,1407000,8760,14,256798000,0,6064116,119609619,125673735,116,112893140,2747882,9870790,0,0,0,0,0,477926,0,2274,1326,0,475339,7436,13582973,53,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,"Gallons",24224936,139600,0,0.41,0.03,0,13170 "Tennessee Valley Authority",18642,1999,"Gallatin","Gas Turbine","01/01/75","1/1/1975",325200,431000,8760,8,176258000,0,3324533,63486109,66810642,205,80539157,665541,6810251,0,0,0,0,0,151587,0,1339166,1553,0,3922,4338,8976358,51,,0,0,0,0,0,0,0,"Mcf",2252179,1024,0,2.67,2.61,0,0,"Gallons",2063233,139100,0,0.37,0,0.03,14710 "Tennessee Valley Authority",18642,1999,"Browns Ferry","Nuclear","01/01/74","1/1/1977",3456000,2529000,8760,1085,1.771301e+10,890631,909522117,3830292072,4740704820,1372,47061477,58344025,102890781,3642332,11672365,0,0,16130309,26099224,0,5560106,0,25822517,1921329,0,252082988,14,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,"MillionBTU",186421503,0,0,0,0.53,0,10520 "Tennessee Valley Authority",18642,1999,"Cumberland","Steam","01/01/73","1/1/1973",2600000,2591000,8760,323,1.6530325e+10,1829568,103903145,1638681020,1744413733,671,63827428,5077791,197194700,0,86656,0,0,3945,13987241,0,1210473,1306476,16946838,4232440,841362,240887922,15,"Tons",6868849,10459,26.16,27.86,1.2,0.01,9746,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"Thomas H. Allen","Gas Turbine","01/01/71","1/1/1972",820300,622000,8760,9,264695000,0,3063638,102977658,106041296,129,1709273,879771,11709062,0,0,0,0,0,72128,0,301000,0,0,150309,2816,13115086,50,,0,0,0,0,0,0,0,"Mcf",3589538,1024,0,3.06,3.03,0,0,"Gallons",1173222,139500,0,0.55,0,0.03,14460 "Tennessee Valley Authority",18642,1999,"Colbert","Gas Turbine","01/01/72","1/1/1972",476000,420000,8760,7,326221000,0,2826177,64911682,67737859,142,3078759,1248563,12167389,0,0,0,0,0,69117,0,27275,0,0,74,2699,13515117,41,,0,0,0,0,0,0,0,"Mcf",3866688,1024,0,2.8,2.71,0,0,"Gallons",3619161,138400,0,0.35,0,0.03,13670 "Tennessee Valley Authority",18642,1999,"Bull Run","Steam","01/01/67","1/1/1967",950000,912000,8760,87,4389788000,2220883,35786684,300943172,338950739,357,21987402,2324904,50419615,0,2286709,0,0,1742,6906593,0,754423,481980,8505768,2788903,314448,74785085,17,"Tons",1593346,11895,28.85,30.74,1.24,0.01,9257,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"Thomas H. Allen","Steam","01/01/59","1/1/1959",990000,858000,8760,122,4102572000,142024,73025058,451231229,524398311,530,20254094,1206283,60294160,0,16,0,0,0,9854407,0,392524,824748,8011764,5402527,184253,86170682,21,"Tons",2039487,9680,25.5,29.45,1.39,0.01,10585,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"Watts Bar","Steam","01/01/42","1/1/1945",240000,0,8760,0,-1381000,11997,4933530,18578656,23524183,98,-6629,177,0,0,0,0,0,0,109802,0,908,5,0,0,0,110892,-80,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"Paradise","Steam","01/01/63","1/1/1970",2558200,2286000,8760,296,1.4181992e+10,8519495,115906466,1287447341,1411873302,552,57696636,6093708,168293657,0,752026,0,0,536,10779025,0,3529172,4127133,18094770,3094627,676700,215441354,15,"Tons",6332104,10413,21.43,26.2,1.14,0.01,10280,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"Gallatin","Steam","01/01/56","1/1/1959",1255200,992000,8760,131,7002818000,690082,44703289,427469961,472863332,377,5073325,1612720,80238724,0,1258244,0,0,73323,7350012,0,1803476,714460,6039653,3054984,792751,102938347,15,"Tons",3266195,9540,22.99,24.49,1.19,0.01,9651,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"John Sevier","Steam","01/01/55","1/1/1957",800000,748000,8760,129,5522165000,1570328,37309270,253176616,292056214,365,2993416,946133,70531483,0,3286201,0,0,0,4864155,0,569877,953882,3537596,666934,559907,85916168,16,"Tons",2120222,11710,32.44,33.21,1.3,0.01,9802,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"Kingston","Steam","01/01/54","1/1/1955",1700000,1583000,8760,275,1.0147089e+10,3475653,55125946,433125237,491726836,289,31839874,1201130,133624099,0,732904,0,0,671,15993919,0,2888077,697638,10886872,3114678,359796,169499784,17,"Tons",4038449,11134,31.75,32.96,1.34,0.01,9845,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"Colbert","Steam","01/01/55","1/1/1965",1350000,1283000,8760,222,6557785000,279029,50717782,608908796,659905607,489,12808186,3684548,92134159,0,115314,0,0,3096,11894009,0,1552144,1216679,16776178,4392373,150021,131918521,20,"Tons",2890398,10787,27.4,31.47,1.38,0.01,10066,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"Shawnee","Steam","01/01/53","1/1/1956",1750000,1368000,8760,264,8060005000,504507,64076435,534941906,599522848,343,20760203,5379072,113531307,0,6565666,0,0,278,7470171,0,2988378,2163530,11022440,5415043,396055,154931940,19,"Tons",3766896,10234,28.54,29.83,1.34,0.01,10474,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"Johnsonville","Steam","01/01/51","1/1/1959",1485200,1213000,8760,269,6638234000,87967,76839994,522564850,599492811,404,5328716,12443723,83697340,0,-481100,0,0,6321,6501533,0,2973740,1891947,6444598,2867797,430252,116776151,18,"Tons",2922958,11389,26.49,28.52,1.16,0.01,10912,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Tennessee Valley Authority",18642,1999,"Widows Creek","Steam","01/01/52","1/1/1965",1968760,1652000,8760,332,8498846000,855691,74795817,748521437,824172945,419,22653730,3695032,119092329,0,6555644,0,0,1697,9854746,0,1449646,2594983,13869309,4635675,4932791,166681852,20,"Tons",3858785,10808,28.8,30.16,1.27,0.01,10896,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"PALO VERDE 17.49%","n","01/01/86","01/01/88",666364,659000,8760,0,5317709000,1244457,281584974,735793972,1018623403,1529,6013000,4282694,25651422,2986065,4032493,0,0,2276671,26939892,0,5837013,1933729,6303817,3749209,2418208,86411213,16,,0,0,0,0,0,0,0,"BBTU",57406,0,0,440.13,0.44,0.01,10795,,0,0,0,0,0,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"San Tan","Combined Cy","01/01/74","01/01/75",414000,292000,4112,43,714062000,149179,2773141,65463525,68385845,165,-5000,380221,14107193,0,1594474,0,0,0,845877,0,332730,170816,0,7389209,249749,25070269,35,,0,0,0,0,0,0,0,"MCF",6579686,1017,2.12,2.12,2.08,0.02,9372,"BBL",291,485968,0,24.61,4.22,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"SOLAR PV1 & PV2","So1ar","01/01/98","01/01/98",216,100,3000,0,119493,0,0,1676818,1676818,7763,1852000,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"KYRENE","Steam","01/01/52","01/01/54",108000,106000,736,12,50072000,313326,2433283,15283485,18030094,167,726000,180057,1483303,0,338591,0,0,169009,304652,0,157896,27729,608781,344347,214929,3829294,76,,0,0,0,0,0,0,0,"MCF",651225,1016,2.16,2.16,2.12,0.03,13215,,0,0,0,0,0,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"KYRENE","Gas Turbine","01/01/71","01/01/73",226850,149000,290,0,18990000,0,0,16888448,16888448,74,0,114913,724438,0,85074,0,0,0,40298,0,64493,11249,0,291038,96634,1428137,75,,0,0,0,0,0,0,0,"MCF",281631,1017,2.09,2.09,2.06,0.04,15094,"BBL",60,488889,0,24.61,4.19,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"MOHAVE 10%","Steam","01/01/71","01/01/71",163620,158000,8715,0,996913000,42812,5046928,50920964,56010704,342,1221000,250561,13703464,0,389195,0,0,245787,1776796,-12611,497248,178489,1673455,685271,112185,19499840,20,"Tons",457815,10939,28.47,29.64,1.35,0.01,10093,"MCF",45107,1028,0,2.94,2.86,0,0,,0,0,0,0,0,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"CORONADO","Steam","01/01/79","01/01/80",821880,760000,8760,213,5039392000,8300198,158523884,696108809,862932891,1050,7523000,1228492,96325127,0,4607490,0,0,403466,4002498,10446,1754276,1703703,12035645,3902862,1238765,127212770,25,"Tons",2632698,9886,34.53,35.42,1.79,0.02,10357,,0,0,0,0,0,0,0,"BBL",24155,137315,24.21,26.79,4.65,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"CRAIG 29%","Steam","01/01/79","01/01/81",259414,248000,8760,0,2050747000,83589,52424794,181936864,234445247,904,680000,368849,22362014,0,1036824,0,0,425951,1689040,12271,323682,251566,1760910,701820,370069,29302996,14,"Coal",1040589,10060,22.56,21.42,1.06,0.01,10223,"MCF",28100,1000,0,2.49,2.49,0,0,,0,0,0,0,0,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"CROSS CUT","Steam","01/01/42","01/01/49",30000,3000,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,"MCF",0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"NAVAJO 21.7%","Steam","01/01/74","01/01/76",522857,488000,8760,539,3676183000,42866,27115117,246304509,273462492,523,5605000,1396220,45545213,0,1123640,0,0,257918,3750053,132023,667722,165042,7069421,2110905,434407,62652564,17,"Tons",1685726,10956,23.51,26.74,1.22,0.01,10061,,0,0,0,0,0,0,0,"BBL",8625,139078,22.75,28.63,4.9,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"NAVAJO 100%","Steam","01/01/74","01/01/76",2409480,2250000,8760,539,1.6020912e+10,197537,124954457,1135043822,1260195816,523,25829493,6236459,196347455,0,5554459,0,0,1293757,8406791,0,3306198,769371,29759456,10024854,2263428,263962228,16,"Tons",7339290,10979,23.5,26.63,1.21,0.01,10074,,0,0,0,0,0,0,0,"BBL",39756,139079,22.75,22.47,3.85,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"FOUR CORNERS 10%","Steam","01/01/69","01/01/70",163620,148000,8760,0,1176172000,11573,7334703,91939839,99286115,607,37000,105696,11684589,0,978340,0,0,90099,1040379,83795,135949,61864,1112429,291525,340786,15925451,14,"Tons",644302,8885,17.41,17.97,1.01,0.01,9757,"MCF",26430,1008,0,4.13,4.1,0,0,,0,0,0,0,0,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"HAYDEN 50%","Steam","01/01/76","01/01/76",137700,131000,6809,0,812423000,482702,13855905,64632670,78971277,574,16419000,157050,8427442,0,469402,0,0,101091,1360780,0,245277,92834,431566,123971,241674,11651087,14,"Tons",413486,10561,22.49,20.28,0.96,0.01,10759,,0,0,0,0,0,0,0,"BBL",1248,138870,26.63,32.67,5.6,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"AGUA FRIA","Steam","01/01/57","01/01/61",390472,407000,4062,62,888092000,139014,5833721,51714773,57687508,148,23000,345003,21091146,0,1032200,0,0,1186582,715713,0,741888,530777,2232219,897096,413430,29186054,33,,0,0,0,0,0,0,0,"MCF",9553025,1009,2.14,2.14,2.12,0.02,10859,"BBL",3,500000,0,24.61,4.1,0,0 "Salt River Proj Ag I & P Dist",16572,1999,"AGUA FRIA","Gas Turbine","01/01/74","01/01/75",222950,197000,451,0,42223000,0,299904,22692012,22991916,103,0,108584,1469697,0,233742,0,0,0,36481,0,284381,9332,0,296342,34359,2472918,59,,0,0,0,0,0,0,0,"MCF",617372,1007,2.12,0,2.1,0.03,14371,,0,0,0,0,0,0,0 "Alexandria City",298,1999,,"STEAM","01/01/56","01/01/74",171000,170000,5326,20,194429,0,0,0,0,0,0,708998,0,0,0,0,0,0,0,0,199997,14994,0,404462,0,1328451,6833,,0,0,0,0,0,0,0,"MCF",2346281,10,2.24,2.24,2.14,0.03,12.45,,0,0,0,0,0,0,0 "Ames City of",554,1999,,"STEAM","01/01/50",,102500,103000,8760,45,381623000,0,0,0,0,0,0,4120850,6152121,0,0,0,0,0,0,0,0,0,0,0,0,10272971,27,,239196,8800,25.72,25.72,1.46,0.02,11031,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Ames City of",554,1999,,"GAS TURBINE","01/01/72","1/1/1972",22000,18000,95,0,1007000,0,0,0,0,0,0,9422,53460,0,0,0,0,0,0,0,0,0,0,0,0,62882,62,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,99000,137300,0.54,0.54,3.93,0.05,13498 "Anaheim City of",590,1999,,"GAS TRUBINE","01/01/90","01/01/91",49270,45998,638,6,27719000,0,9226000,27237000,36463000,740,0,280835,699954,0,0,0,0,0,0,0,187223,0,0,0,1146979,2314991,84,,0,0,0,0,0,0,0,"MCF",258683,1009,2.76,2.76,2.74,25.7,9394,,0,0,0,0,0,0,0 "Anchorage City of",599,1999,"#1","4 Gas 2 Int","01/01/62","01/01/72",85000,33000,1010,14,9983618,80839,3457655,22418738,25957232,305,380194,55796,353989,0,0,0,0,809120,0,3922,67280,67353,0,442853,0,1800313,180,,0,0,0,0,0,0,0,273580,0,1000,1.38,1.38,1.38,0.03,19744,778,0,133500,33.82,33.82,6.03,0,0 "Anchorage City of",599,1999,"#2","3 Gas 1 Ste","01/01/75","01/01/84",243200,151000,19516,30,759258360,11240,8928538,75136820,84076598,346,5364843,257796,10642281,0,678572,0,0,1623991,233929,0,330573,231135,303990,1190866,118352,15611485,21,,0,0,0,0,0,0,0,7701758,0,1000,1.38,1.38,1.38,0.01,10144,570,0,133500,34.71,34.71,6.19,0,0 "Austin City of",1009,1999,"Downtown","Gas Turbine","01/01/54","01/01/54",5500,5000,0,0,493000,0,0,1065016,1065016,194,0,142,36663,0,0,0,0,7532,0,0,143,0,0,142049,0,186529,378,,0,0,0,0,0,0,0,"MCF",1347,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Austin City of",1009,1999,"Northeast","Steam","01/01/71","01/01/71",31500,31300,7566,24,120607160,70498,2376720,5711293,8158511,259,0,42490,2760067,0,395223,0,0,366434,798118,0,24135,51518,290200,20129,3652,4751966,39,"TON",58175,12000,39.8,39.48,1.64,0.02,12637,"MCF",125541,1020,2.75,2.75,2.7,0.03,12648,,0,0,0,0,0,0,0 "Austin City of",1009,1999,"Downtown","Steam","01/01/35","01/01/54",27500,22500,465,11,4508000,24099,1221355,5587700,6833154,248,0,31568,193351,0,41643,0,0,12652,492890,0,23781,136549,88433,55977,1897,1078741,239,,0,0,0,0,0,0,0,"MCF",70119,1020,2.75,2.75,2.7,0.04,15874,,0,0,0,0,0,0,0 "Austin City of",1015,1999,"DECKER TURBINES","GAS TURBINE","01/01/88","01/01/88",200000,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Austin City of",1015,1999,"DECKER SOLAR","SOLAR","01/01/86","01/01/86",300,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Austin City of",1015,1999,"DECKER","STEAM","01/01/70","01/01/77",726000,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Austin City of",1015,1999,"HOLLY","STEAM","01/01/60","01/01/74",558000,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Austin City of",1015,1999,"SEAHOLM","STEAM","01/01/51","01/01/55",120000,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Braintree Town of",2144,1999,"Potter II","Gas Turbine","01/01/77","01/01/77",97500,79500,1284,27,72929000,20271,3762859,18429374,22212504,228,132748,176565,2625145,0,1154442,0,0,0,0,0,158096,316309,488498,491410,262035,5672500,78,,0,0,0,0,0,0,0,"MCF",931167,1035,3.03,3.03,2.92,0.03,11631,"BBLS",14190,138809,15.72,15.72,2.7,0.03,10520 "Brownsville Public Utils Board",2409,1999,"SILAS RAY","STEAM GAS T","01/01/46","01/01/77",155000,197000,5256,29,206,528443,4499041,192117166,197144650,1272,0,205477,6239714,0,1311,0,0,155739,309455,0,74856,224382,203068,176038,1264465,8854505,42983034,,0,0,0,0,0,0,0,"MCF",2346974,1059,2.65,2.65,2.5,0.03,12048,,0,0,0,0,0,0,0 "Bryan City of",2439,1999,,"Gas Turbine","01/01/70","01/01/87",39,30,265,8,5177,0,0,0,0,0,0,0,311874,0,0,0,0,499578,0,0,0,0,0,216081,0,1027533,198480,,0,0,0,0,0,0,0,"Mcf",72688,1000,3.8,3.8,3.8,0.06,29839,"Bbl29839",639,128000,55.63,55.63,7.12,0.06,29839 "Bryan City of",2442,1999,"Bryan Municipal","STEAM, GAS","01/01/55","01/01/74",138000,115000,0,20,118273000,0,7590674,7546886,15137560,110,46427,76607,3529286,0,372623,0,0,606045,154868,9320,63805,20315,520977,159461,31344,5544651,47,,0,0,0,0,0,0,0,"MCF",1626575,1,2.25,2.25,2.21,0.03,14.05,,0,0,0,0,0,0,0 "Bryan City of",2442,1999,"Roland C. Dandy","STEAM","01/01/77","01/01/77",105000,106000,0,19,461142000,1183486,10201555,18752019,30137060,287,105283,76291,11510542,0,391030,0,0,512056,181517,12858,53081,31539,405327,91686,57727,13323654,29,,0,0,0,0,0,0,0,"MCF",5120070,1,2.24,2.24,2.21,0.02,11.36,,0,0,0,0,0,0,0 "Burlington City of",2548,1999,"Gas Turbine","Gas Turbine","01/01/71","01/01/71",25500,25000,106,1,2093500,13587,531143,3214616,3759346,147,17164,6073,130467,0,0,0,0,324,5442,16648,0,0,0,75762,0,234716,112,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,"BBL",6016,137674,20.61,21.69,3.75,0.06,16616 "Burlington City of",2548,1999,"Joseph C McNeil GenrЬ ","Steam","01/01/84","01/01/84",50,53,4305,48,183109400,278455,18147811,50484579,68910845,1378217,571376,140467,6439721,0,788415,0,0,291816,360657,0,131396,35661,553086,1325161,20193,10086573,55,"Wood-Tons",263762,4750,23.46,23.52,2.47,0.03,13742,"MCF",66041,1012124,2.82,2.82,2.78,0.24,86785,"BBL",2260,136430,20.13,21.19,3.7,0,71.02 "Cedar Falls City of",3203,1999,"Streeter Station","Steam","01/01/63","01/01/73",51500,50000,1650,23,38111600,281328,3758281,14375110,18414719,358,699506,97410,1113417,0,230220,0,0,102634,142771,0,90418,180725,588058,55402,9122,2610177,68,"Tons",19527,12429,38.79,36.49,1.47,0.02,14033.99,"MCF",49410,1000,2.75,2.75,2.75,0.04,14033.99,,0,0,0,0,0,0,0 "Cedar Falls City of",3203,1999,"Combustion Turbine","Combustion","01/01/68","01/01/68",25000,20000,193,0,2814300,70777,134588,3497629,3702994,148,3062,4978,122537,0,0,0,0,5713,0,0,6674,9708,0,32837,0,182447,65,,0,0,0,0,0,0,0,"MCF",50599,1000,2.42,2.42,2.42,0.04,17979.25,,0,0,0,0,0,0,0 "California Dept-Wtr Resources",3255,1999,"Reid Garner #4","Steam-coal","01/01/83","01/01/83",275000,250000,0,96,1597086000,319709000,0,0,319709000,1163,0,0,22054817,0,0,0,0,0,21659183,0,0,0,0,0,0,43714000,27,"Tons",672949,11858,0,13.11,1.31,0.01,11079,,0,0,0,0,0,0,0,"Barrels",7515,133622,0,25,4.55,0.05,11570 "California Dept-Wtr Resources",3255,1999,"BottleRock & S Geysep","Steam-Geoth","01/01/85","01/01/85",55000,0,0,0,0,10000,0,0,10000,0,0,0,0,0,0,0,0,0,553000,0,0,0,0,0,0,553000,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Chanute City of",3355,1999,"Plant #3","Internal Co","01/01/85","01/01/91",31915,39975,595,8,10378156,50000,612000,15500000,16162000,506,0,369525,245371,0,0,0,0,0,0,0,166666,0,0,136912,0,918474,89,"N/A",0,0,0,0,0,0,0,"MCF",78668,1000,2.66,2.66,2.66,0.02,0.02,"Barrels",3969,138000,26.57,26.57,0.08,0.01,0.01 "PUD No 1 of Clark County",3660,1999,"River Road CCCT","Gas Turbine","01/01/97","01/01/97",248000,258504,7058,21,1711891704,1053160,141767983,13187783,156008926,629,2319343,4203148,23066109,0,0,0,0,0,0,0,0,91900,0,0,0,27361157,16,,0,0,0,0,0,0,0,"MCF",11463,1060,2042,2012,1.9,0.01,7114,,0,0,0,0,0,0,0 "Clarksdale City of",3702,1999,,"Combine Cyc","01/01/71","01/01/71",25550,24000,2149,6,43507,0,0,4581109,4581109,179,0,10000,1053091,0,0,0,0,130000,80000,0,10000,0,12009,328580,0,1623680,37320,,0,0,0,0,0,0,0,"MCF",374997,1000,2.8,2.8,2.8,0.02,8.62,"BBL",70,142.5,23.14,23.14,3.86,0.05,13.99 "Clarksdale City of",3702,1999,,"Gas Turbine","01/01/65","01/01/65",11500,11500,754,6,12158,0,0,1445133,1445133,126,0,10000,478409,0,0,0,0,100000,50000,0,20000,0,0,226974,0,885383,72823,,0,0,0,0,0,0,0,"MCF",169662,1000,2.8,2.8,2.8,0.03,13.99,"BBL",115,142.5,23.14,23.14,3.86,0.07,20.18 "Coffeyville City o",3892,1999,"COFFEYVILLE","STEAM","01/01/01","01/01/73",56985,55900,4013,23,68578900,0,0,0,0,0,0,57285,2419645,0,0,0,0,0,1146750,0,0,0,8610,0,0,3632290,53,,0,0,0,0,0,0,0,"MMBTU",938070,1000,2.25,2.58,2.58,0.03,1368,,0,0,0,0,0,0,0 "Coldwater Board of Public Util",3915,1999,,"Steam","01/01/00","01/01/64",11125,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,68864,7301,41,105,51389,127700,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Coldwater Board of Public Util",3915,1999,,"Diesel","01/01/48","01/01/78",13250,45933,1719,6,7081208,0,0,0,0,0,0,40423,214682,0,0,0,0,37863,0,0,0,12739,0,71418,0,377125,53,,0,0,0,0,0,0,0,"Mcf",65604,9530000,2.84,0,0,0,0,"Barrels",1725,126000,17.7,0,0,0,0 "Colorado Springs City of",3989,1999,"Birdsall","Steam-Gas","01/01/53","01/01/57",62500,4500,1717,4,20716000,10761,2593301,11384249,13988311,224,0,67716,1180669,0,107787,0,0,227078,88988,0,31363,89311,290603,224308,38374,2346197,113,,0,0,0,0,0,0,0,"MCF",412714,806,2.83,2.83,3.52,0.06,16212,"GALLONS",22000,137420,0.11,0.11,0.81,0.01,16212 "Colorado Springs City of",3989,1999,"Drake","Steam-Gas","01/01/25","01/01/74",257300,256000,8760,106,1484262000,2725551,23014851,80547185,106287587,413,0,1059853,25816108,0,1094453,0,0,3228406,1184954,0,462905,237248,4111443,1735831,152472,39083673,26,"TONS",769313,10914,29.13,31.49,1.44,0.01,11585,"MCF",494125,808,2.73,2.73,3.38,0.03,11585,"BARRELS",0,0,0,0,0,0,0 "Colorado Springs City of",3989,1999,"Nixon","Steam-Gas","01/01/80","01/01/80",207000,214000,6081,81,1117841000,5059222,39785705,107090082,151935009,734,0,969721,11571054,0,779121,0,0,1343687,1057607,0,489855,218501,3309067,2974204,146609,22859426,20,"TONS",538337,10432,18.31,18.84,0.9,0,10120,,0,0,0,0,0,0,0,"BARRELS",13952,136738,24.87,24.87,4.33,0.04,10120 "Colorado Springs City of",3989,1999,"CTS","Gas","01/01/99","01/01/99",71660,73000,458,0,22292000,418573,123167,32084223,32625963,455,0,0,715385,0,0,0,0,0,0,0,0,0,0,26204,0,741589,33,,0,0,0,0,0,0,0,"MCF",291394,983,2.89,2.87,2.92,0.03,12852,,0,0,0,0,0,0,0 "Columbia City of",4045,1999,,"Steam/Gas T","01/01/10","01/01/70",86000,226000,8760,46,62152000,115894,3578025,15986526,19680445,229,5320808,43503,2133251,0,531664,0,0,967929,376491,0,170114,28005,512239,452108,0,5215304,84,"Tons",37319,13265,53.83,53.69,2.02,3.22,15930,"Mcf",34179,0,3.64,3.64,0,0,0,,0,0,0,0,0,0,0 "Columbus City of",4065,1999,"O'Shaughnessy",,,,5000,5000,0,1,5860000,0,0,0,0,0,0,0,0,0,0,0,0,49898,0,0,0,0,0,2864,0,52762,9,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Concord City of",4150,1999,,,,,0,0,0,0,545243,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Connecticut Mun Elec Engy Coop",4180,1999,"Millstone Unit 3","Nuclear (e)","01/01/86","01/01/86",1253100,1164700,7329,933,8277624400,0,20415627,29930688,50346315,40,0,324496,363329,24201,162455,0,0,48209,296706,13608,313554,74201,315415,228127,1354,2165655,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Dalton City of",4744,1999,"Wansley 1 & 2","Coal fired","01/01/76","01/01/78",22220,0,0,0,149590620,0,0,9113036,9113036,410,28304,29233,2186381,0,24950,0,0,15863,81536,0,42895,19710,138435,167350,13819,2720172,18,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Dalton City of",4744,1999,"Scherer 1 & 2","Coal fired","/ /","01/01/84",22680,0,0,0,144814966,0,0,13467749,13467749,594,50818,27106,2605498,0,25617,0,0,15303,77539,0,34949,22981,256897,16076,11927,3093893,21,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Denton City of",5063,1999,"SPENCER PLANT","STEAM","01/01/55","01/01/73",179000,259100,11980,36,305539695,0,0,0,0,0,0,233373,9138796,0,348227,0,0,468112,432003,0,71604,11794,211613,467529,210327,11593378,38,,0,0,0,0,0,0,0,"Mcf",3800668,1,2.24,2.24,2.24,2.99,12.43,"BBl",0,139.68,7.82,0,0,0,0 "Eugene City of",6022,1999,"Willamette","Steam","01/01/31","01/01/50",25000,0,0,0,0,0,0,1189332,1189332,48,0,0,260,0,1204,0,0,-975,0,0,0,0,0,5095,7459,13043,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Eugene City of",6022,1999,"Energy Center","Steam","01/01/76","01/01/76",51200,41000,0,0,192829000,1280,320371,7521672,7843323,153,0,13058,1366594,0,0,0,0,261785,0,0,0,94,0,127793,0,1769324,9,,0,0,0,0,0,0,0,,321587,0,2.51,0,0,0,2495.24,,0,0,0,0,0,0,0 "Farmington City of",6204,1999,"ANIMAS","STEAM-COMBI","01/01/55","01/01/94",32180,28000,7808,14,170805000,5968,1109574,25033191,26148733,813,0,70145,3611891,0,225548,0,0,460952,226694,0,122984,0,217797,1021413,38103,5995527,35,,0,0,0,0,0,0,0,"MCF",1668856,1013,2.13,2.13,2.1,0.02,9897,,0,0,0,0,0,0,0 "Farmington City of",6204,1999,"SAN JUAN","STEAM-COAL","/ /","/ /",4300042200,43000,7919,10,293222700,0,5471749,62874731,68346480,0,0,71242,5641682,0,114021,0,0,120758,93838,131,62021,34762,382623,77158,65298,6663534,23,"TONS",167448,9421,32.33,32.33,1.72,0.01,10774,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Fayetteville Public Works Comm",6235,1999,"Butler-Warner Gen PtP","Gas-Turbine","01/01/76","01/01/88",303400,276500,1134,33,0,749336,5123088,100277060,106149484,350,4108529,0,-6665,0,0,0,0,0,0,0,0,0,0,292639,-141172,144802,0,,0,0,0,0,0,0,0,"Mcf",1724674,1046,2.72,2.72,2.6,0.03,12249.5,"Barrels",4,138800,27.15,27.87,4.78,0.06,13375.25 "Fort Pierce Utilities Auth",6616,1999,"Steam","Steam","01/01/21","01/01/89",120011,0,0,0,0,0,0,0,0,0,0,564929,6990,0,231196,0,0,428922,138247,0,21508,56082,204594,1437831,87424,3177723,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0 "Freeport Village of Inc",6775,1999,"Power Plant #1","Internal Co",,"01/01/64",13190,0,0,9,2066120,5022,1113459,3036221,4154702,315,51721,42612,209909,0,0,0,0,518539,0,0,0,79604,0,0,0,850664,412,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,"Barrels",293755,138788,0.81,0.68,0.18,0.97,14.88 "Freeport Village of Inc",6775,1999,"Power Plant #2","Internal Co","1/1/1968","01/01/73",37390,57000,1,9,1277200,1827,3178208,8088951,11268986,301,0,52596,205053,0,0,0,0,634322,0,28573,0,101784,0,0,0,1022328,800,,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,"Barrels",319336,138788,0.86,0.64,0.13,0.16,9.2 "Fremont City of",6779,1999,"Wright","Steam","01/01/56","01/01/76",132700,83390,8760,47,336075,202231,5905920,42850719,48958870,369,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,0,,0,0,0,0,0,0,0,,0,0,0,0,0

  2. 1. CNTRAT IDCODE PAGE OF PGES AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1 PDF icon 1 More Documents & Publications Microsoft Word - GJPPGPracticesDraft.doc Updated Section H Greening Clauses DOE Purchase Card Policy

    CNTRAT IDCODE PAGE OF PGES AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1 OTATI OEPG FIP 5S 2, AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE (M/IJ/Y) 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 313 See Block 16C1 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy Office of River

  3. 1. CONTRACT ID CODE PAGE OF PAGES AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT I11 5

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Ap5,sval 2700042 1. CONTRACT ID CODE PAGE OF PAGES AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT I11 5 2. AMENDMENT/MOOIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO.5 PROJECT NO. (If applicable) A077 See 16C 06-08RL-14383.O1 1 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODEJ US. Department of Energy Same as item 6. Richland Operations Office DOE Contracting POC: Richard Stimmrrel P. 0. Box 550, MSIN A7-80 (509) 376-2882 Richland, WA 99352 8 NAME AND

  4. 1. CONTRACT ID CODE PAGE OF PAGES AMENDMENT OF SOLICITATIONIMODIFICATION OF CONTRACT I111 5

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AMENDMENT OF SOLICITATIONIMODIFICATION OF CONTRACT I111 5 2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applica ble) A078 See 16C 06-08RL14383.012 6. ISSUED BY CODE1 7. ADMINISTERED BY (If other than Item ) CODEJ U.S. Department of Energy Same as item 6. Richland Operations Office DOE Contracting POC: Richard Stimmel P. 0. Box 550, MSIN A7-80 (509) 376-2882 Richland, WA 99352 8. NAME AND ADDRESS OF CONTRACTOR (No. Street, county, Stale and

  5. 1. CONTRACT ID CODE PAGE OF PAGES AMENDMENT OF SOLICITATIONIMODIFICATION OF CONTRACT II11 5

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AMENDMENT OF SOLICITATIONIMODIFICATION OF CONTRACT II11 5 2. AMEN DMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REOUISITIONIPURCHASE REQ. NO. 5. PROJECT NO. (if applicable) A07 I ee 6C06-08RL143 83 .013 6.ISE YCDJ7. ADMINISTERED BY If lother than Item 6) CODEJ U.S. Department of Energy Same as item 6. Richland Operations Office DOE Contracting POC: Richard Stimmel P. 0. Box 550, MSTN A7-80 (509) 376-2882 Richland, WA 99352 _________ 8. NAME AND ADDRESS OF CONTRACTOR (No. Street, county, State and

  6. 1. CONTRACT ID CODE PAGE of: PAGES AMENDM ENT OF SOLICITATION/MODIFICATION OF CONTRACT I -1 5

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    of: PAGES AMENDM ENT OF SOLICITATION/MODIFICATION OF CONTRACT I -1 5 2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE (0/1T 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 286 See Block 16C 12EM0014771 6. ISSUED BY CODE 7. AD)MINISTERED BY (If otherrtianItm 6) CODE U.S. Department of Energy Office of River Protection P. 0. Box 450, MIS 116-60 Richland, WA 99352 8. NAME AND ADDRESS OF CONTRACTOR (No., street. county.. State and ZIP code) 9A. AMENDMENT OF SOLICITATION NO. Bechtel

  7. Passive magnetic bearing element with minimal power losses

    DOE Patents [OSTI]

    Post, R.F.

    1998-12-08

    Systems employing passive magnetic bearing elements having minimal power losses are provided. Improved stabilizing elements are shown, employing periodic magnet arrays and inductively loaded circuits, but with improved characteristics compared to the elements disclosed in US Patent No. 5,495,221 entitled ``Dynamically Stable Magnetic Suspension/Bearing System.`` The improvements relate to increasing the magnitude of the force derivative, while at the same time reducing the power dissipated during the normal operation of the bearing system, to provide a passive bearing system that has virtually no losses under equilibrium conditions, that is, when the supported system is not subject to any accelerations except those of gravity. 8 figs.

  8. Shape-influenced Magnetic Properties of CoO Nanoparticles (Journal Article)

    Office of Scientific and Technical Information (OSTI)

    | SciTech Connect Shape-influenced Magnetic Properties of CoO Nanoparticles Citation Details In-Document Search Title: Shape-influenced Magnetic Properties of CoO Nanoparticles Authors: Kundu, S ; Nelson, A J ; McCall, S K ; VanBuuren, A W ; Liang, H Publication Date: 2013-03-04 OSTI Identifier: 1104522 Report Number(s): LLNL-JRNL-625473 DOE Contract Number: W-7405-ENG-48 Resource Type: Journal Article Resource Relation: Journal Name: Journal of Nanoparticle Research, vol. 15, no. 5, March

  9. draft

    Energy Savers [EERE]

    3 (08-93) U.S. Department of Energy ORDER FOR SUPPLIES OR SERVICES ORDER FOR SUPPLIES OR SERVICES PAGE OF PAGES IMPORTANT: Mark all packages and papers with contract and/or order numbers. 1. DATE OF ORDER 2. CONTRACT NO. (if any) 3. ORDER NO. 4. REQUISITION/REFERENCE NO. 5. ISSUING OFFICE (Address correspondence to) BUYER NO. CODE 6. SHIP TO: (Consignee and address, ZIP Code) SHIP VIA: 7. TO CONTRACTOR (Name, address and ZIP Code) 8. TYPE OF ORDER 9 9 A. PURCHASE - Reference

  10. OMB Approval 2700-0042

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    5 2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) A029 See 16C 06RL14383.007 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy Richland Operations Office P. O. Box 550, MSIN A7-80 Richland, WA 99352 Same as item 6. 8. NAME AND ADDRESS OF CONTRACTOR (No. Street, county, State and ZIP: Code) ( ) 9A. AMENDMENT OF SOLICITATION NO. AdvanceMed Corp Computer Sciences Corp 9B. DATED (SEE ITEM 11)

  11. OMB Approval 2700-0042

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2 2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) A031 See 16C 06RL14383.M01 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy Richland Operations Office P. O. Box 550, MSIN A7-80 Richland, WA 99352 Same as item 6. 8. NAME AND ADDRESS OF CONTRACTOR (No. Street, county, State and ZIP: Code) ( ) 9A. AMENDMENT OF SOLICITATION NO. AdvanceMed Corp Computer Sciences Corp 9B. DATED (SEE ITEM 11)

  12. Microsoft Word - SF30 M080 _Final_.DOC

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    57 PAGE OF PAGES AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE 1 3 2. AMENDMENT/MODIFICATION NO. M080 3. EFFECTIVE DATE (M/D/Y) See Block 16C 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy Office of River Protection P. O. Box 450, MS H6-60 Richland, WA 99352 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP code) 9A. AMENDMENT OF SOLICITATION

  13. Microsoft Word - Final Report - Acquisition and Project Management

    Office of Environmental Management (EM)

    DOE F 4600.1# U.S. DEPARTMENT OF ENERGY (11/04) NOTICE OF FINANCIAL ASSISTANCE AWARD Under the authority of Public Law 1. PROJECT TITLE 2. INSTRUMENT TYPE GRANT COOPERATIVE AGREEMENT 4. INSTRUMENT NO. 5. AMENDMENT NO. 3. RECIPIENT (Name, address, zip code) 6. BUDGET PERIOD FROM: THRU: 7. PROJECT PERIOD FROM: THRU: 8. RECIPIENT PROJECT DIRECTOR (Name, phone and E-mail) 9. RECIPIENT BUSINESS OFFICER (Name, phone and E-mail) 10. TYPE OF AWARD NEW CONTINUATION RENEWAL REVISION INCREMENTAL FUNDING

  14. Research Highlight

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Retrieving Cloud Characteristics from Ground-Based Daytime Color All-Sky Images Submitter: Long, C. N., NOAA Global Monitoring Division/CIRES Area of Research: Cloud Distributions/Characterizations Working Group(s): Cloud Properties Journal Reference: Long, C. N., J. M. Sabburg, J. Calbo, and D. Pages, (2006): Retrieving Cloud Characteristics from Ground-based Daytime Color All-sky Images, JTech, 23, No. 5, 633–652. Long, C. N., J. M. Sabburg, J. Calbo, and D. Pages, (2006): Papers of Note:

  15. Approval/Variation Request Comment Sheet

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    EA15PC3041-3-0 Mar. 25, 2003 Rev. 0 Page 1 of 2 Approval/Variation Request Comment Sheet 1. Page of 2. G APPROVAL REQUEST 3. G VARIATION REQUEST 4. AR/VR No. 5. PO/Subcontract No. 6. Organization 7. Reviewer 8. Comment: 9. Disposition: Working Copy EA15PC3041-3-0 Mar. 25, 2003 Rev. 0 Page 2 of 2 Instructions for Filling Out Approval/Variation Request Comment Sheet Block 1. Technical Reviewer - Enter the total number of pages upon completion of the review. 2. Technical Reviewer - Check the

  16. APS storage ring vacuum chamber tests for dimensional stability after bakeout cycling while under vacuum

    SciTech Connect (OSTI)

    Wehrle, R.; Nielsen, R.

    1990-09-01

    Vacuum chamber sections No. 1 and No. 2 were used for these tests. Section No. 1, a short straight section, is representative in these tests of Sections No. 3 and No. 5 as well. Section No. 2 is the longer curved section used within the dipole bend magnets and is representative of the similar Section No. 4. The combination of Sections No. 1 and No. 2 joined by a connected bellows was mounted as presently planned for the final installation. This afforded an early testing of chamber positional stability after bakeout cycling. Tests of chamber dimensional stability were also made during vacuum cycling.

  17. Microsoft Word - M047 WEB PAGE.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    5 2. AMENDMENT/MODIFICATION NO. M047 3. EFFECTIVE DATE (M/D/Y) see block 16 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy Office of River Protection P. O. Box 450, MS H6-60 Richland, WA 99352 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP code) 9A. AMENDMENT OF SOLICITATION NO. Bechtel National, Inc. 2435 Stevens Center Place 9B. DATED (SEE ITEM 11) Richland, WA

  18. Microsoft Word - M051 SF 30.doc

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    M051 3. EFFECTIVE DATE (M/D/Y) See Block 16C 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy Office of River Protection P. O. Box 450, MS H6-60 Richland, WA 99352 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP code) 9A. AMENDMENT OF SOLICITATION NO. Bechtel National, Inc. 2435 Stevens Center Place 9B. DATED (SEE ITEM 11) Richland, WA 99352 10A. MODIFICATION OF

  19. Earth melter with rubble walls and method of use

    DOE Patents [OSTI]

    Chapman, Chris C.

    1998-01-01

    The present invention is an improvement to the earth melter described and claimed in U.S. Pat. No. 5,443,618. The improvement is the use of rubble for retaining walls. More specifically, the retaining walls rest on ground level and extend above ground level piling rubble around a melt zone. A portion of the melter may be below grade wherein sidewalls are formed by the relatively undisturbed native soil or rock, and the rubble may be used as a backfill liner for the below grade sidewalls.

  20. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

    National Nuclear Security Administration (NNSA)

    Page 1 of 4 PAGES 2. AMENDMENT/MODIFICATION NO. M0538 3. EFFECTIVE DATE See Block 16C 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE U.S. Department of Energy National Nuclear Security Administration Sandia Site Office (MS 0184) P.O. Box 5400 Albuquerque, NM 87185-5400 7. ADMINISTERED BY (If other than Item 6) CODE 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, state, ZIP Code) Sandia Corporation P. O. Box 5800 Albuquerque, NM 87185 9A. AMENDMENT OF

  1. 2D MODIFICATION OF A CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    14 3. EFFECTIVE DATE (M/D/Y) See Block 16C 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy Office of River Protection P. O. Box 450, MS H6-60 Richland, WA 99352 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP code) 9A. AMENDMENT OF SOLICITATION NO. Washington River Protection Solutions LLC P.O. Box 73 9B. DATED (SEE ITEM 11) 720 Park Blvd Boise, ID. 83729-0001 10A.

  2. 2D MODIFICATION OF A CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    17 2. AMENDMENT/MODIFICATION NO. A015 3. EFFECTIVE DATE (M/D/Y) 04/07/09 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy Office of River Protection P. O. Box 450, MS H6-60 Richland, WA 99352 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP code) 9A. AMENDMENT OF SOLICITATION NO. Washington River Protection Solutions LLC P.O. Box 73 9B. DATED (SEE ITEM 11) 720 Park Blvd

  3. 2D MODIFICATION OF A CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    3 3. EFFECTIVE DATE (M/D/Y) See Block 16C 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy Office of River Protection P. O. Box 450, MS H6-60 Richland, WA 99352 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP code) 9A. AMENDMENT OF SOLICITATION NO. Washington River Protection Solutions LLC P.O. Box 73 9B. DATED (SEE ITEM 11) 720 Park Blvd Boise, ID. 83729-0001 10A.

  4. DOE_Response_2008-02.pdf

    Office of Environmental Management (EM)

    F 4600.1# U.S. DEPARTMENT OF ENERGY (7/05) NOTICE OF FINANCIAL ASSISTANCE AWARD Under the authority of Public Law 1. PROJECT TITLE 2. INSTRUMENT TYPE GRANT COOPERATIVE AGREEMENT 4. INSTRUMENT NO. 5. AMENDMENT NO. 3. RECIPIENT (Name, address, zip code) 6. BUDGET PERIOD FROM: THRU: 7. PROJECT PERIOD FROM: THRU: 8. RECIPIENT PROJECT DIRECTOR (Name, phone and E-mail) 9. RECIPIENT BUSINESS OFFICER (Name, phone and E-mail) 10. TYPE OF AWARD NEW CONTINUATION RENEWAL REVISION INCREMENTAL FUNDING 11. DOE

  5. Passive magnetic bearing element with minimal power losses

    DOE Patents [OSTI]

    Post, Richard F.

    1998-01-01

    Systems employing passive magnetic bearing elements having minimal power losses are provided. Improved stabilizing elements are shown, employing periodic magnet arrays and inductively loaded circuits, but with improved characteristics compared to the elements disclosed in U.S. Patent No. 5,495,221 entitled "Dynamically Stable Magnetic Suspension/Bearing System." The improvements relate to increasing the magnitude of the force derivative, while at the same time reducing the power dissipated during the normal operation of the bearing system, to provide a passive bearing system that has virtually no losses under equilibrium conditions, that is, when the supported system is not subject to any accelerations except those of gravity.

  6. Part III - List of Documents, Exhibits, and Other Attachments

    National Nuclear Security Administration (NNSA)

    OF PAGES 1 2 2. AMENDMENT/MODIFICATION NO . 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable} 229 See Block 16C 6. ISSUED BY CODE 05003 7. ADMINISTERED BY {If other than Item 6) CODE 05003 NNSA/Los Alamos Site Office U. S . Department of Energy Los Alamos Site Office 3747 West Jemez Road Los Alamos NM 87544 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code) LOS ALAMOS NATIONAL SECURITY , LLC Attn: STEVE K. SHOOK P.O. BOX 1663, MS P222 LOS

  7. ________________________________________________________________

    National Nuclear Security Administration (NNSA)

    AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE 1 OF 1 PAGE 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 2. AMENDMENT/MODIFICATION NO. M051 See Block 16 C 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy National Nuclear Security Administration Manager, Los Alamos Site Office 3747 West Jemez Road Los Alamos, NM 87544 9A. AMENDMENT OF SOLICITATION NO. 9B. DATED (SEE ITEM 11) 8. NAME AND

  8. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

    National Nuclear Security Administration (NNSA)

    9 11. CONTRACT 10 CODE 1PAGE OF PAGES AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1 I 25 2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ . NO . 5 PROJECT NO. (If applicab/e) See Bl ock 1 6C 1 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE 105007 NNSA / Pantex Site Office 05007 NNSA/Pantex Site Office U.S. Department of Energy U.S. Department of Energy Nt SA/ Pantex S it e Offi ce NNSA/Pantex Site Office P.O. Box 30030 P . O . Box 30030

  9. AMENDMENT OF SOLICITATIONIMODIFICATION OF CONTRACT

    National Nuclear Security Administration (NNSA)

    PAGE OF PAGES AMENDMENT OF SOLICITATIONIMODIFICATION OF CONTRACT 1 I 2 2. AMENDMENTIMODIFICATION NO. 3. EFFECTIVE DATE 4 . REOUISITIONIPURCHASE REO NO . 5 PROJECT NO. (II applicable) 213 6. ISSUED BY CODE 07/ 01 / 2010 05008 7. ADMINISTERED BY (llolherlhan lIem 6) 1 CODE 105008 NNSA/ Oakridge Site Office U.S. Department of Energy NNSA / Y-12 Site Office P.O . Box 2050 Building 9704-2 Oak Ridge TN 37831 8. NAME AND ADDRESS OF CONTRACTOR (No .* streel. counly. Slale and ZIP Code) NNSA/Oakridge

  10. Block 14 entitled, Description of Amendment/Modification is continued as follows:

    National Nuclear Security Administration (NNSA)

    CONTRACT ID CODE PAGE OF PAGES 1 6 2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 001 1/26/2015 6. ISSUED BY CODE MOSD 7. ADMINISTERED BY (If other than Item 6) Code U.S. DEPARTMENT OF ENERGY NATIONAL NUCLEAR SECURITY ADMINISTRATION M&O CONTRACTING (NA-APM-131) PO BOX 5400, ALBUQUERQUE, NM 87185-5400 8. NAME AND ADDRESS OF CONTRACTOR (No. street, county, State and ZIP Code) (X) 9.A. AMENDMENT OF SOLICITATION NO. DE-SOL-0007749

  11. AMEN DMENT OF SOLICITATION/MODIFICATION OF CONTRACT r* CONTRACT ID CODE

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AME:NDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT 10 CODE PAGE 1 OF 224 PAGES 2. AMENDMENT/MODIFICATION NO. M202 3. EFFECTIVE DATE October 1, 2003 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.s. Department of Energy N.itional Nuclear Security Administration Sandia Site Office Mail Stop 0184 P.O. Box 5400 AlbuauerQue, NM 87185-5400 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, state, ZIP

  12. AMENDMENT OF SOLICITATION/MODIFICATION

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    OF CONTRACT 1.CNRTIDOEPAE1 FI G 4 2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE (MD Y) 4. REQUISITONPURC1-ASE REQ NO. 5. PROJECT NO. (ijappiceubc) 277 See Block 16C 6. ISSUED BY CODE 7. ADMINISTERED BY (If ther than Item 6) CODE U.S. Department of Energy Office of River Protection P. 0. Box 450, MIS 1-6-60 Richland, WA 99352 8. NAME AND ADDRESS OF CONTRACTOR (No. street, county, State and ZiI' code) 9A AMENDMENT OF SOLICITATION NO. Bechtel National, Inc. 9B. DATED 1 'SEE 171AM )) 2435 Stevens

  13. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    10 CODE \ PAGE OF PAGES 1 I 2 2. AMENDMENTIMODIFICATION NO. 3. EFFECTIVE DATE 4. REOUISITIONIPURCHASE REO. NO. \5. PROJECT NO. (If applicable) 330 See Block 16C 11SC007443 Item 11 6. ISSUED BY CODE 00518 7. ADMINISTERED BY (If other than Item 6) CODE \00518 Oak Ridge Oak Ridge U.S. Department of Energy U.S. Department of Energy P.O. Box 2001 P.O. Box 2001 Oak Ridge TN 37831 Oak Ridge TN 37831 8. NAME AND ADDRESS OF CONTRACTOR (No., street, COWlIy, Ststo and ZIP Corio) (X) 9A. AMENDMENT OF

  14. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    CONTRACT 10 CODE 1 PAGE OF PAGES 1 1 2 2. AMENDMENTIMODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. /5. PROJECT NO. (If applicable) 340 See Block 16C 12SC000849 Item 6 6. ISSUED BY CODE 00518 7. ADMINISTERED BY (If other than Item 6) CODE 100518 Oak Ridge Oak Ridge U.S. Department of Energy U.S. Department of Energy P.O. Box 2001 P.O. Box 2001 Oak Ridge TN 37831 Oak Ridge TN 37831 8. NAME AND ADDRESS OF CONTRACTOR (No., stroet, coooty, Stote /JIId ZIP Code) (x) 9A. AMENDMENT

  15. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    CONTRACT 10 CODE I PAGE OF PAGES 1 I 2 2. AMENDMENTIMODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. \5. PROJECT NO. (If applicable) 360 See Block 16C 12SC002265 6. ISSUED BY CODE 00518 7. ADMINISTERED BY (If other than Item 6) CODE 100518 Oak Ridge u.s. Department of Energy P.O. Box 2001 Oak Ridge TN 37831 8. NAME AND ADDRESS OF CONTRACTOR (No .* stfl)et. county, Slolo ond ZIP Codo) AK RIDGE ASSOCIATED UNIVERSITIES, o P o INC. .0. BOX 117 AK RIDGE TN 37830-6218 CODE

  16. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    12TATI OE AE O AE 2. AMEN DM ENT/MOD IF ICATION NO. 3. EFFECTIVE DAI E (A! DY) 4. REQUISITION/PURCHASE RE-Q. NO. 5. PROJECT NO. (If applicable) 035 See Block 16C IIEM002483 6. ISSUED BY CODE 7. ADMINISTERED BY (If oth/ir than Items 6) CODE U.S. Department of Energy Office of River Protection P. 0. Box 450, MS H6-60 Richland, WA 99352 8. NAME AND ADDRESS OF CONTRA( bR (No., street, countv, State and ZIP code) 9A. AMENDMENT OF SOLICITATION NO. Advanced Techniologies and Laboratories (ATE) D 9B.

  17. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    . CONTRACT ID CODEPAEOPGS 2. AMENDMENT/MODIFI CATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 046 See Block 16C 12EM000343 6 ISSUED BY CODE 00603 7. ADMINISTERED BY (If otherthan Item 6) CODE 100603 Office of River Protection Office of River Protection U.S. Depar7nent of Energy UJ.S. Department of Energy Office of River Protection Office of River Protection P.O. Box 450 P.O. Box 450 Richiand WA 99352 Richiand WA 99352 8. NAME AND ADDRESS OF

  18. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES 1 20 2. AMENDMENT/MODIFICATION NO. A001 3. EFFECTIVE DATE See Block 16C 4. REQUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy National Energy Technology Laboratory PO Box 880, 3610 Collins Ferry Road Morgantown, WV 26507-0880 Attn: Amanda Lopez 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State, and

  19. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1. 3OTATI OE AE O AE

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    3OTATI OE AE O AE 2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE (A't'VY) 4. REOUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 199 See Block 16C N/A 6. ISSUED BY CODE 7. ADMINISTERED BY (If other than Item 6) CODE U.S. Department of Energy Office of River Protection P. 0. Box 450, MS 1-6-60 Rich land, WA 99352 8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP code) 9A. AMENDMENT OF SOLICITATION NO. Bechtel National, Inc. D 98. DATED (SEE ITEM 11) 2435 Stevens

  20. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1.CNTAT ID CODE PAGE "OF PAGES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    CNTAT ID CODE PAGE "OF PAGES 1 11 3 2. AMEN DME NT/MO0D IFICATION NO. 3. EFFECTIVE DATE 4. REOUISITION/PURCHASE REQ, NO. 5. PROJECT NO. (if applicable) 6. SSED Y ODE00037. ADMINISTERED BY (If'other than Item 6) CODE 00603 Office of River Protection Office of River Protection U.S. Department of Energy U.S. Department of Energy Office of River Protection Office of River Protection P.O. Box 450 P.O. Box 450 Richiand WA 99352 MS: H16-60 ____________________________________Richland WA 99352 8

  1. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT 1.CONTRACT ID CODE PAGE OF PAGES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    CONTRACT ID CODE PAGE OF PAGES T 1 1 13 2 AMENDIMENT/MODIFICATION NO 3. EFFECTIVE DATE 4 -REGUISITION/PURCHASE RED. NO 5. PROJECT NO. (If epplicable) 032 04/14/2011 11EM002244 6 ISSUED BY CODE 00603 7 ADMINISTERED BY (Iftherthan temrt6) CODE J00603 Office of River Protection Office of River Protection U.S. Department of Energy U.S. Department of Energy Office of River Protection office of River Protection P.O. Box 450 P.O. Box 450 Richland WA 99352 Richland WA 99352 8 NAME AND ADDRESS OF

  2. AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT r' CONTRACT 10 CODE I

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    2 2. AMENDMENTIMODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE REO. NO. \5. PROJECT NO. (II applicable) 328 See Block 16C 11SC007443 Item 9 6. ISSUED BY CODE 00518 7. ADMINISTERED BY (II other than Item 6) CODE 100518 Oak Ridge Oak Ridge U.S. Department of Energy U.S. Department of Energy P.O. Box 2001 P.O. Box 2001 Oak Ridge TN 37831 Oak Ridge TN 37831 8. NAME AND ADDRESS OF CONTRACTOR (No .* street. county. Stato and ZIP Code} ~ 9A. AMENDMENT OF SOLICITATION NO. OAK RIDGE ASSOCIATED

  3. AMENDMENT OF SOLICITATIONIMODI FICATION OF CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    SOLICITATIONIMODI FICATION OF CONTRACT 1 OTATI OEP AE 2. AMENDMENT/MODIFICATION NO. 3. EFFECTIEDT 4. REOUISITION/PURCHASE REQ. NO. 5. PROJECT NO. (If applicable) 166 See Block 16C 6- ISSUED BY CODE 100603 7. ADMINISTERED BY If lother than Item 6) CODE 100603 Office of River Protection Office of River Protection U.S. Department of Energy U.S. Department of Energy Office of River Protection Office of River Protection P.O. Box 450 P.O. Box 450 Richland WA 99352 MS: H6-60 Richland WA 99352 B. NAME

  4. AMENDMENT OF SOLICITATIONIMODIFICATION OF CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    11. CONTRACT 10 CODE I PAGE OF PAGES 1 I 2 2. AMENDMENTIMODIFICATION NO. 3. EFFECTIVE DATE 4. REQUISITIONIPURCHASE REQ. NO. \5. PROJECT NO. (If applicable) 361 See Block 16C 12SC002265 6. ISSUED BY CODE 00518 7. ADMINISTERED BY (If other than Item 6) CODE 100518 Oak Ridge Oak Ridge U.S. Department of Energy U.S. Department of Energy P.O. Box 2001 P.O. Box 2001 Oak Ridge TN 37831 Oak Ridge TN 37831 8. NAME AND ADDRESS OF CONTRACTOR (No .* streat. county. Stata and ZIP Coda) ~ 9A AMENDMENT OF

  5. AMENDMENT OF SOLICITATIONIMODIFICATION OF CONTRACT

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    .CNRC 3DCDE PAGE OF PAGES 2. AMENDMENT/MODIFICATION NO. 3. EFFECTIVE DATE 4. REOUISITIONIPURCHASE RED. NO. 5. PROJECT NO. (If app/ice ble) 167 See Block 16C 6. ISSUED BY CODE 00603 7. ADMINISTERED BY If lother than Iteml 6) CODE 100603 Office of River Protection Office of River Protection U.S. Department of Energy U.S. Department of Energy Office of River Protection Office of River Protection P.O. Box 450 P.O. Box 450 Richlandi WA 99352 MS: H6-60 ____________________________________Richland WA

  6. AMENDMENT OF SOLICITATIONIMODIFICATION OF CONTRACT 1. CONTRACT ID CODE P AE

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    OF CONTRACT 1. CONTRACT ID CODE P AE 2. AMEN DMENT/MODIF ICATION NO. 3. EFFECTIVE DATE 4. REQUISITION/PURCHASE RED. NO. 5. PROJECT NO. (If applicable) 073 See Block 16C 12EM002951/12EM003004 6. ISSUED BY CODE 100603 7. ADMINISTERED BY (If other than Item 6) CODE 100603 Office of River Protection Office of River Protection U.S. Department of Energy U.S. Department of Energy Office of River Protection Office of River Protection P.O. Box 450 P.O. Box 450 Richland WA 99352 Richland WA 99352 8. NAME

  7. AMENDMENT OF SOLICITATIONIMODIFICATION OF CONTRACT I CONTRACT ID CODE PAGE OF PAGES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    I CONTRACT ID CODE PAGE OF PAGES 1 14 2. AMENDMENT/MODIFICATION NO. 3 EFFECTIVE DATE 4. REQUISITION/PURCHASE RED. NO 5. PRtOJECT NO. (if pplicable) 186 See Block 16CL 6. ISSUED BY CODE j 0603 7. ADMINISTERED BY (If other than Item 6) CODE 00603 office of River Protection Office of River Protection U.S. Department of Energy U.S. Department of Energy office of River Protection office of River Protection P.O. Box 450 P.O. Box 450 Richland WA 99352 MS: H6-60 Richland WA 99352 6. NAME AND ADDRESS OF

  8. AMENDMENT OF SOUCITATIONIMODIFICATION OF CONTRACT 1. CONTRACT ID CODE PAGE OF PAGES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    1. CONTRACT ID CODE PAGE OF PAGES II 11 9 2. AMEN DMENTIMODIFICATION NO. 3. EFFECTIVE DATE 4. REOUISITIONIPURCHASE REQ. NO. 5. PROJECT NO. (If elpicable) 169 See Block 16C 12EM0020631 6. ISSUED BY CODE 00603 7. ADMINISTERED BY (If otherthan Item 6) CODE 100603 Office of River Protection Office of River Protection U.S. Department of Energy U.S. Department of Energy Office of River Protection Office of River Protection P.O. Box 450 P.O. Box 450 Richland WA 99352 MS: H6-60

  9. B. Linzau, DNFSB R. G. Quirk, DNFSB A. B. Dunning, WRPS L. L. Eppler, WRPS

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Mr. Charles G. Spencer -3- MAR 0 1 2011, 11 1-AMD-054 cc w/attach: B. Linzau, DNFSB R. G. Quirk, DNFSB A. B. Dunning, WRPS L. L. Eppler, WRPS R. L. Garrett, WRPS L. J. Kripps, WRPS WRPS Correspondence Attachment to I I1-AMD-054 Amendment of SolicitationlModification of Contract 094 (Total Number of Pages, 3) AMENDMENT OF SOLICITATION/'MODIFICATION OF CONTRACT 1. CONTRACT ID CODEPAEOPGS 2. AM ENDM ENT/MODI F ICATION NO. 3. EFFECTIVE DATE 4. REOUISITION/PURCHASE REQ. NO. 5. PROJECT NO (If

  10. Solvent Refined Coal (SRC) process. Quarterly technical progress report, January 1979-March 1979

    SciTech Connect (OSTI)

    Not Available

    1980-02-01

    This report summarizes the progress of the Solvent Refined Coal (SRC) Project by the Pittsburg and Midway Coal Mining Co. for the Department of Energy for the period January 1, 1979 to March 31, 1979. Activities included the operation and modification of the Solvent Refined Coal Pilot Plant at Fort Lewis, Washington; the Process Development Unit P-99 at Harmarville, Pennsylvania; and research at Merriam Laboratory in Merriam, Kansas. The Pilot Plant processed Powhatan No. 5 Coal in the SRC-II mode of operation studying the effect of coal particle size and system temperature on coal slurry blending and the effect of carbon monoxide concentration in the reaction feed gas on process yields. January and February were spent completing installation of a fourth High Pressure Separator on Process Development Unit P-99 to better simulate operating conditions for the proposed Demonstration Plant. During March, one run was completed at P-99 feeding Pittsburgh Seam Coal from the Powhatan No. 5 Mine. Merriam investigations included a study of the effect of iron containing additives on SRC-I operation, the addition of carbon monoxide to the feed gas, utilization of a hydrogenated solvent (Cresap process solvent) in the SRC-I mode under both normal and short residence time operating conditions, and development of a simulated distillation technique to determine the entire boiling range distribution of product oils.

  11. Production of Illinois base compliance coal using enhanced gravity separation. Technical report, March 1, 1994--May 31, 1994

    SciTech Connect (OSTI)

    Paul, B.C.; Honaker, R.Q.

    1994-09-01

    It is well known that froth flotation is inefficient for treating fine coal fractions containing a significant portion of middling particles. On the other hand, gravity-based processes can effectively remove middling particles containing only a small amount of coal. Falcon Concentrators Inc. and Knelson Gold Concentrators Inc. have developed full-scale, enhanced gravity separators for the treatment of heavy minerals. This project is evaluating the potential of using these concentrators to treat Illinois Basin coal fines. During this reporting period, -28 mesh run-of-mine Illinois No. 5 and No. 6 coal samples were processed using a continuous Falcon concentrator having a 10-inch bowl diameter. For the Illinois No. 5 coal sample, the ash content was reduced in the 100 {times} 325 mesh size fraction from about 18% to 8% while achieving a high combustible recovery value of nearly 97%. In addition, the total sulfur content was substantially decreased from 2.6% to 1.7%. Similar results were obtained from the treatment of the Illinois No. 6 coal sample where ash rejections ranged from 40%-70% for a 28 {times} 325 mesh feed having 7% ash. Combustible recovery values from these tests were greater than 87% while treating mass feed rates between 1 to 2 tons/hour. A parametric study found that lower feed solids contents provided marginally lower product ash and total sulfur contents while feed rate and bowl speed appeared to have no significant effect over the range of values tested.

  12. Transportation energy strategy: Project {number_sign}5 of the Hawaii Energy Strategy Development Program

    SciTech Connect (OSTI)

    1995-08-01

    This study was prepared for the State Department of Business, Economic Development and Tourism (DBEDT) as part of the Hawaii Energy Strategy program. Authority and responsibility for energy planning activities, such as the Hawaii Energy Strategy, rests with the State Energy Resources Coordinator, who is the Director of DBEDT. Hawaii Energy Strategy Study No. 5, Transportation Energy Strategy Development, was prepared to: collect and synthesize information on the present and future use of energy in Hawaii`s transportation sector, examine the potential of energy conservation to affect future energy demand; analyze the possibility of satisfying a portion of the state`s future transportation energy demand through alternative fuels; and recommend a program targeting energy use in the state`s transportation sector to help achieve state goals. The analyses and conclusions of this report should be assessed in relation to the other Hawaii Energy Strategy Studies in developing a comprehensive state energy program. 56 figs., 87 tabs.

  13. Titanium addition practice, and maintenance for the hearths in AHMSA`s blast furnaces

    SciTech Connect (OSTI)

    Boone, A.G.; Jimenez, G.; Castillo, J.

    1997-12-31

    Altos Hornos de Mexico (AHMSA) is a steel company located in Northern Mexico, in the state of Coahuila. Currently there are three blast furnaces in operation and one more about to finish its general repair. This last one is to remain as a back-up unit. Because of blast furnace hearth wear outs AHMSA has developed some maintenance procedures. These procedures are based on titanium ore additions and hearth thermic control monitoring. There are also some other maintenance practices adopted to the working operations to assure that such operations detect and avoid in time hearth wear outs that place personnel and/or the unit in danger (due to hearth leaks). This paper describes titanium ore addition to No. 2 blast furnace during the final campaign and it also illustrates maintenance practices and continuous monitoring of temperature trends both of which were implemented at AHMSA`s No. 5 blast furnace.

  14. Carbon adsorption system protects LPG storage sphere

    SciTech Connect (OSTI)

    Gothenquist, C.A.; Rooker, K.M.

    1996-07-01

    Chevron U.S.A. Products Co. installed a carbon adsorption system to protect an LPG storage sphere at its refinery in Richmond, Calif. Vessel damage can result when amine contamination leads to emulsion formation and consequent amine carry-over, thus promoting wet-H{sub 2}S cracking. In Chevron`s No. 5 H{sub 2}S recovery plant, a mixture of butane and propane containing H{sub 2}S is contacted with diethanolamine (DEA) in a liquid-liquid absorber. The absorber is a countercurrent contactor with three packed beds. Because the sweetening system did not include a carbon adsorption unit for amine purification, contaminants were building up in the DEA. The contaminants comprised: treatment chemicals, hydrocarbons, foam inhibitors, and amine degradation products. The paper describes the solution to this problem.

  15. Combined passive magnetic bearing element and vibration damper

    DOE Patents [OSTI]

    Post, Richard F.

    2001-01-01

    A magnetic bearing system contains magnetic subsystems which act together to support a rotating element in a state of dynamic equilibrium and dampen transversely directed vibrations. Mechanical stabilizers are provided to hold the suspended system in equilibrium until its speed has exceeded a low critical speed where dynamic effects take over, permitting the achievement of a stable equilibrium for the rotating object. A state of stable equilibrium is achieved above a critical speed by use of a collection of passive elements using permanent magnets to provide their magnetomotive excitation. In a improvement over U.S. Pat. No. 5,495,221, a magnetic bearing element is combined with a vibration damping element to provide a single upper stationary dual-function element. The magnetic forces exerted by such an element, enhances levitation of the rotating object in equilibrium against external forces, such as the force of gravity or forces arising from accelerations, and suppresses the effects of unbalance or inhibits the onset of whirl-type rotor-dynamic instabilities. Concurrently, this equilibrium is made stable against displacement-dependent drag forces of the rotating object from its equilibrium position.

  16. Recovery efficiency test project, Phase 2 activity report. Volume 2, Final report

    SciTech Connect (OSTI)

    Overbey, W.K. Jr.; Salamy, S.P.; Locke, C.D.

    1989-02-01

    The Recovery Efficiency Test well project addressed a number of technical issues. The primary objective was to determine the increased efficiency of gas recovery of a long horizontal wellbore over that of a vertical wellbore and, more specifically, what improvements can be expected from inducing multiple hydraulic fractures from such a wellbore. This volume contains appendices for: (1) supporting material and procedures for ``data frac`` stimulation of zone 6 using nitrogen and nitrogen foam; (2) supporting material and procedures for stimulation no. 1 nitrogen gas frac on zone no. 1; (3) supporting material and procedures for stimulation no. 2 in zone no. 1 using liquid CO{sub 2}; (4) supporting material and procedures for frac no. 3 on zone no.1 using nitrogen foam and proppant; (5) supporting material and procedures for stimulation no. 4 in zones 2--3 and 4 using nitrogen foam and proppant; (6) supporting materials and procedures for stimulation no. 5 in zones 5 and 8; and (7) fracture diagnostics reports and supporting materials.

  17. Recovery efficiency test project, Phase 2 activity report

    SciTech Connect (OSTI)

    Overbey, W.K. Jr.; Salamy, S.P.; Locke, C.D.

    1989-02-01

    The Recovery Efficiency Test well project addressed a number of technical issues. The primary objective was to determine the increased efficiency of gas recovery of a long horizontal wellbore over that of a vertical wellbore and, more specifically, what improvements can be expected from inducing multiple hydraulic fractures from such a wellbore. This volume contains appendices for: (1) supporting material and procedures for data frac'' stimulation of zone 6 using nitrogen and nitrogen foam; (2) supporting material and procedures for stimulation no. 1 nitrogen gas frac on zone no. 1; (3) supporting material and procedures for stimulation no. 2 in zone no. 1 using liquid CO{sub 2}; (4) supporting material and procedures for frac no. 3 on zone no.1 using nitrogen foam and proppant; (5) supporting material and procedures for stimulation no. 4 in zones 2--3 and 4 using nitrogen foam and proppant; (6) supporting materials and procedures for stimulation no. 5 in zones 5 and 8; and (7) fracture diagnostics reports and supporting materials.

  18. Evaluation of exposure pathways to man from disposal of radioactive materials into sanitary sewer systems

    SciTech Connect (OSTI)

    Kennedy, W.E. Jr.; Parkhurst, M.A.; Aaberg, R.L.; Rhoads, K.C.; Hill, R.L.; Martin, J.B.

    1992-05-01

    In accordance with 10 CFR 20, the US Nuclear Regulatory Commission (NRC) regulates licensees` discharges of small quantities of radioactive materials into sanitary sewer systems. This generic study was initiated to examine the potential radiological hazard to the public resulting from exposure to radionuclides in sewage sludge during its treatment and disposal. Eleven scenarios were developed to characterize potential exposures to radioactive materials during sewer system operations and sewage sludge treatment and disposal activities and during the extended time frame following sewage sludge disposal. Two sets of deterministic dose calculations were performed; one to evaluate potential doses based on the radionuclides and quantities associated with documented case histories of sewer system contamination and a second, somewhat more conservative set, based on theoretical discharges at the maximum allowable levels for a more comprehensive list of 63 radionuclides. The results of the stochastic uncertainty and sensitivity analysis were also used to develop a collective dose estimate. The collective doses for the various radionuclides and scenarios range from 0.4 person-rem for {sup 137}Cs in Scenario No. 5 (sludge incinerator effluent) to 420 person-rem for {sup 137}Cs in Scenario No. 3 (sewage treatment plant liquid effluent). None of the 22 scenario/radionuclide combinations considered have collective doses greater than 1000 person-rem/yr. However, the total collective dose from these 22 combinations was found to be about 2100 person-rem.

  19. Development of automatic operation system for coke oven machines at Yawata Works of Nippon Steel Corporation

    SciTech Connect (OSTI)

    Matsunaga, Masao; Uematsu, Hiroshi; Nakagawa, Yoji; Ishiharaguchi, Yuji

    1995-12-01

    The coke plant is a working environment involving heavy dust emissions, high heat and demanding physical labor. The labor-saving operation of the coke plant is an essential issue from the standpoints of not only improvement in working environment, but also reduction in fixed cost by enhancement of labor productivity. Under these circumstances, Nippon Steel has implemented the automation of coke oven machines. The first automatic operation system for coke oven machinery entered service at Oita Works in 1992, followed by the second system at the No. 5 coke oven battery of the coke plant at Yawata Works. The Yawata automatic operation system is characterized by the installation of coke oven machinery to push as many as 140 ovens per day within a short cycle time, such as a preliminary ascension pipe cap opening car and cycle time simulator by the manned operation of the pusher, which is advantageous from the standpoint of investment efficiency, and by the monitoring of other oven machines by the pusher. These measures helped to reduce the manpower requirement to 2 persons per shift from 4 persons per shift. The system entered commercial operation in March, 1994 and has been smoothly working with an average total automatic rate of 97%. Results from the startup to recent operation of the system are reported below.

  20. Solvent Refined Coal (SRC) process. Quarterly technical progress report, April 1979-June 1979

    SciTech Connect (OSTI)

    Not Available

    1980-02-01

    This report summarizes the progress of the Solvent Refined Coal (SRC) Project for the period March 25, 1979, through June 24, 1979. SRC-I turnaround activities at the Fort Lewis Pilot Plant and several other problems delayed successful startup until April 11. Slurry was injected to the Lummus Deashing Unit for the first time April 12. After approximately eight days, slurry feed was diverted because of indications that solids were accumulating in the settler vessel. The Fort Lewis Pilot Plant was shut down from April 28 to May 12, 1979, while the Lummus Unit settler vessel was hydroblasted. Cleaning of the settler vessel was complete May 10. Modifications to the unit were nearly complete at the end of the reporting period. Slurry feed to the Lummus Unit was reestablished June 15. To date, continuous production of specification product at design rates has not been achieved. One material balance run, MBR 79-1, was completed using Kentucky No. 9/14 coal at proposed design conditions for the SRC-I Demonstration Plant. Process Development Unit P-99 was on-stream for all of the second quarter of 1979, with the exception of a two-week scheduled turn-around. Six different run conditions were tested feeding Pittsburgh Seam coal from the Powhatan No. 5 Mine.

  1. Controlling orbital-selective Kondo effects in a single molecule through coordination chemistry

    SciTech Connect (OSTI)

    Tsukahara, Noriyuki; Kawai, Maki; Takagi, Noriaki; Minamitani, Emi; Kim, Yousoo

    2014-08-07

    Iron(II) phthalocyanine (FePc) molecule causes novel Kondo effects derived from the unique electronic structure of multi-spins and multi-orbitals when attached to Au(111). Two unpaired electrons in the d{sub z}{sup 2} and the degenerate d? orbitals are screened stepwise, resulting in spin and spin+orbital Kondo effects, respectively. We investigated the impact on the Kondo effects of the coordination of CO and NO molecules to the Fe{sup 2+} ion as chemical stimuli by using scanning tunneling microscopy (STM) and density functional theory calculations. The impacts of the two diatomic molecules are different from each other as a result of the different electronic configurations. The coordination of CO converts the spin state from triplet to singlet, and then the Kondo effects completely disappear. In contrast, an unpaired electron survives in the molecular orbital composed of Fe d{sub z}{sup 2} and NO 5? and 2?* orbitals for the coordination of NO, causing a sharp Kondo resonance. The isotropic magnetic response of the peak indicates the origin is the spin Kondo effect. The diatomic molecules attached to the Fe{sup 2+} ion were easily detached by applying a pulsed voltage at the STM junction. These results demonstrate that the single molecule chemistry enables us to switch and control the spin and the many-body quantum states reversibly.

  2. Airborne gamma-ray spectrometer and magnetometer survey. Canyon City quadrangle (Oregon). Final report

    SciTech Connect (OSTI)

    Not Available

    1981-01-01

    Fourteen uranium anomalies meet the minimum statistical requirements as defined in Volume I. These anomalies are listed and are shown on the Uranium Anomaly Interpretation Map. Potassium (%K), equivalent Uranium (ppM eU), equivalent Thorium (eT), eU/eT, eU/K, eT/K, and Magnetic Pseudo Contour Maps are presented in Appendix E. Stacked Profiles showing geologic strip maps along each flight-line, together with sensor data, and ancillary data are presented in Appendix F. All maps and profiles were prepared on a scale of 1:250,000, but have been reduced to 1:500,000 for presentation in Volume II. Anomaly No. 1 is over mainly sedimentary rocks of undifferentitatd Paleozoic/Mesozoic age (MzPza). Anomaly No. 2 is over a fault contact between Strawberry volcanics (Ts), and volcanic rocks of the Clarno (Tc). Anomaly No. 3 is over an intensely faulted block of Strawberry volcanics (Ts). Anomaly No. 4 is over the contact area between Strawberry volcanic rocks (Ts) and a basalt plug of Tertiary age (Tbi). Anomaly No. 5 is over the contact area between volcanic rocks of the Clarno formation (Tc) and undivided sedimentary rocks of Jurassic/Triassic age. Part of the anomaly is over landslide debris (Q1). Anomalies No. 6 and No. 7 are over a fault contact between volcanic rocks of the Clarno formation (Tc) and undivided sedimentary rocks of Jurassic/Triassic age (JTru).

  3. Coal desulfurization by chlorinolysis: production and combustion-test evaluation of product coals. Final report

    SciTech Connect (OSTI)

    Kalvinskas, J.; Daly, D.

    1982-04-30

    Laboratory-scale screening tests were carried out on PSOC 276, Pittsburgh Coal from Harrison County, Ohio to establish chlorination and hydrodesulfurization conditions for the batch reactor production of chlorinolysis and chlorinolysis-hydrodesulfurized coals. In addition, three bituminous coals, Pittsburgh No. 8 from Greene County, PA, Illinois No. 6 from Jackson County, Illinois and Eagle No. 5 from Moffat County, Colorado were treated on the lab scale by the chlorinolysis process to provide 39 to 62% desulfurization. Two bituminous coals (PSOC 276, Pittsburgh Coal from Harrison County, Ohio and 282, Illinois No. 6 Coal from Jefferson County, Illinois) and one subbituminous coal (PSOC 230, Rosebud Coal fom Rosebud County, Montana) were then produced in 11 to 15 pound lots as chlorinolysis and hydrodesulfurized coals. The chlorinolysis coals had a desulfurization of 29 to 69%, reductions in volatiles (12 to 37%) and hydrogen (6 to 31%). Hydrodesulfurization provided a much greater desulfurization (56 to 86%), reductions in volatiles (77 to 84%) and hydrogen (56 to 64%). The three coals were combustion tested in the Penn State plane flame furance to determine ignition and burning characteristics. All three coals burned well to completion as: raw coals, chlorinolysis processed coals and hydrodesulfurized coals. The hydrodesulfurized coals experienced greater ignition delays and reduced burning rates than the other coals because of the reduced volatile content. It is thought that the increased open pore volume in the desulfurized-devolatilized coals compensates in part for the decreased volatiles effect on ignition and burning. 4 figures, 2 tables.

  4. Improved energy efficiency in a specialty paper mill

    SciTech Connect (OSTI)

    Smith, C.D. Jr.

    1986-06-01

    Energy costs at the James River KVP mill have increased sixfold since the 1973 oil embargo. The cost of energy now surpasses the cost of labor and is second only to that of pulp. Economic pressures thus provide a powerful incentive for efficient use of energy. The KVP mill is a nonintegrated mill that is capable of producing up to 450 tons/day of specialty papers. The mill is equipped with six paper machines, six parchment machines, three off-machine coaters, and related converting equipment. Energy is supplied by a central powerhouse that is equipped with: Two gas/oil-fired Combustion Engineering VU50 power boilers, each capable of producing 210,000 lb/h of 850-psig steam at 825/sup 0/F; One gas/oil-fired Riley water tube boiler capable of producing 150,000 lb/h of 220-psig steam at 525/sup 0/F; Two General Electric turbine generators. No. 5 condensing machine: throttle steam, 850 psig; high-pressure extraction, 220 psig; low-pressure extraction, 220 psig; low-pressure extraction, 38 psig; maximum generation, 9500 kW. No. 6 condensing machine: throttle steam, 850 psig; low-pressure extraction, 38 psig; maximum generation, 9500 kW.

  5. Development of a One-Equation Transition/Turbulence Model

    SciTech Connect (OSTI)

    EDWARDS,JACK R.; ROY,CHRISTOPHER J.; BLOTTNER,FREDERICK G.; HASSAN,HASSAN A.

    2000-09-26

    This paper reports on the development of a unified one-equation model for the prediction of transitional and turbulent flows. An eddy viscosity - transport equation for non-turbulent fluctuation growth based on that proposed by Warren and Hassan (Journal of Aircraft, Vol. 35, No. 5) is combined with the Spalart-Allmaras one-equation model for turbulent fluctuation growth. Blending of the two equations is accomplished through a multidimensional intermittence function based on the work of Dhawan and Narasimha (Journal of Fluid Mechanics, Vol. 3, No. 4). The model predicts both the onset and extent of transition. Low-speed test cases include transitional flow over a flat plate, a single element airfoil, and a multi-element airfoil in landing configuration. High-speed test cases include transitional Mach 3.5 flow over a 5{degree} cone and Mach 6 flow over a flared-cone configuration. Results are compared with experimental data, and the spatial accuracy of selected predictions is analyzed.

  6. Innovative Clean Coal Technology (ICCT): Demonstration of selective catalytic reduction (SCR) technology for the control of nitrogen oxide (NO{sub x}) emissions from high-sulfur coal-fired boilers. Technical progress report, third and fourth quarters 1994

    SciTech Connect (OSTI)

    1995-11-01

    The objective of this project is to demonstrate and evaluate commercially available selective catalytic reduction (SCR) catalysts from U.S., Japanese, and European catalyst suppliers on a high-sulfur U.S. Coal-fired boiler. SCR is a post-combustion nitrogen oxide (NO{sub x}) control technology that involves injecting ammonia into the flue gas generated from coal combustion in an electric utility boiler. The flue gas containing ammonia is then passed through a reactor that contains a specialized catalyst. In the presence of the catalyst, the ammonia reacts with NO{sub x} to form nitrogen and water vapor. Although SCR is widely practiced in Japan and European gas-, oil-, and low-sulfur coal-fired boilers, there are several technical uncertainties associated with applying SCR to U.S. coals. These uncertainties include: (1) potential catalyst deactivation due to poisoning by trace metal species present in U.S. coals that are not present in other fuels; (2) performance of the technology and effects on the balance-of-plant equipment in the presence of high amounts of SO{sub 2} and SO{sub 3}; performance of a wide variety of SCR catalyst compositions, geometries, and methods of manufacture under typical high-sulfur coal-fired utility operating conditions. These uncertainties are being explored by operating a series of small- scale SCR reactors and simultaneously exposing different SCR catalysts to flue gas derived from the combustion of high sulfur U.S. coal. The demonstration is being performed at Gulf Power Company`s Plant Crist Unit No. 5 (75 MW capacity) near Pensacola, Florida. The project is funded by the U.S. Department of Energy (DOE), Southern Company Services, Inc. (SCS on behalf of the entire Southern electric system), the Electric Power Research Institute (EPRI), and Ontario Hydro. SCS is the participant responsible for managing al aspects of this project. 1 ref., 69 figs., 45 tabs.

  7. Innovative Clean Coal Technology (ICCT). Technical progress report, second & third quarters, 1993, April 1993--June 1993, July 1993--September 1993

    SciTech Connect (OSTI)

    1995-09-01

    The objective of this project is to demonstrate and evaluate commercially available Selective Catalytic Reduction (SCR) catalysts from U.S., Japanese, and European catalyst suppliers on a high-sulfur U.S. coal-fired boiler. SCR is a post-combustion nitrogen oxide (NOx) control technology that involves injecting ammonia into the flue gas generated from coal combustion in an electric utility boiler. The flue gas containing ammonia is then passed through a reactor that contains a specialized catalyst. In the presence of the catalyst, the ammonia reacts with NOx to convert it to nitrogen and water vapor. Although SCR is widely practiced in Japan and Europe on gas-, oil-, and low-sulfur coal-fired boilers, there are several technical uncertainties associated with applying SCR to U.S. coals. These uncertainties include: (1) potential catalyst deactivation due to poisoning by trace metal species present in U.S. coals that are not present in other fuels; (2) performance of the technology and effects on the balance-of-plant equipment in the presence of high amounts of SO{sub 2} and SO{sub 3}; and (3) performance of a wide variety of SCR catalyst compositions, geometries and methods of manufacture under typical high-sulfur coal-fired utility operating conditions. These uncertainties are being explored by constructing and operating a series of small-scale SCR reactors and simultaneously exposing different SCR catalysts to flue gas derived from the combustion of high sulfur U.S. coal. The demonstration is being performed at Gulf Power Company`s Plant Crist Unit No. 5 (75 MW capacity) near Pensacola, Florida. The project is funded by the U.S. Department of Energy (DOE), Southern Company Services, Inc. (SCS on behalf of the entire Southern electric system), the Electric Power Research Institute (EPRI), and Ontario Hydro. SCS is the participant responsible for managing all aspects of this project.

  8. Monoterpene synthases from common sage (Salvia officinalis)

    DOE Patents [OSTI]

    Croteau, Rodney Bruce; Wise, Mitchell Lynn; Katahira, Eva Joy; Savage, Thomas Jonathan

    1999-01-01

    cDNAs encoding (+)-bornyl diphosphate synthase, 1,8-cineole synthase and (+)-sabinene synthase from common sage (Salvia officinalis) have been isolated and sequenced, and the corresponding amino acid sequences has been determined. Accordingly, isolated DNA sequences (SEQ ID No:1; SEQ ID No:3 and SEQ ID No:5) are provided which code for the expression of (+)-bornyl diphosphate synthase (SEQ ID No:2), 1,8-cineole synthase (SEQ ID No:4) and (+)-sabinene synthase SEQ ID No:6), respectively, from sage (Salvia officinalis). In other aspects, replicable recombinant cloning vehicles are provided which code for (+)-bornyl diphosphate synthase, 1,8-cineole synthase or (+)-sabinene synthase, or for a base sequence sufficiently complementary to at least a portion of (+)-bornyl diphosphate synthase, 1,8-cineole synthase or (+)-sabinene synthase DNA or RNA to enable hybridization therewith. In yet other aspects, modified host cells are provided that have been transformed, transfected, infected and/or injected with a recombinant cloning vehicle and/or DNA sequence encoding (+)-bornyl diphosphate synthase, 1,8-cineole synthase or (+)-sabinene synthase. Thus, systems and methods are provided for the recombinant expression of the aforementioned recombinant monoterpene synthases that may be used to facilitate their production, isolation and purification in significant amounts. Recombinant (+)-bornyl diphosphate synthase, 1,8-cineole synthase and (+)-sabinene synthase may be used to obtain expression or enhanced expression of (+)-bornyl diphosphate synthase, 1,8-cineole synthase and (+)-sabinene synthase in plants in order to enhance the production of monoterpenoids, or may be otherwise employed for the regulation or expression of (+)-bornyl diphosphate synthase, 1,8-cineole synthase and (+)-sabinene synthase, or the production of their products.

  9. Building, Testing, and Post Test Analysis of Durability Heat Pipe No.6

    SciTech Connect (OSTI)

    MOSS, TIMOTHY A.

    2002-03-01

    The Solar Thermal Program at Sandia supports work developing dish/Stirling systems to convert solar energy into electricity. Heat pipe technology is ideal for transferring the energy of concentrated sunlight from the parabolic dish concentrators to the Stirling engine heat tubes. Heat pipes can absorb the solar energy at non-uniform flux distributions and release this energy to the Stirling engine heater tubes at a very uniform flux distribution thus decoupling the design of the engine heater head from the solar absorber. The most important part of a heat pipe is the wick, which transports the sodium over the heated surface area. Bench scale heat pipes were designed and built to more economically, both in time and money, test different wicks and cleaning procedures. This report covers the building, testing, and post-test analysis of the sixth in a series of bench scale heat pipes. Durability heat pipe No.6 was built and tested to determine the effects of a high temperature bakeout, 950 C, on wick corrosion during long-term operation. Previous tests showed high levels of corrosion with low temperature bakeouts (650-700 C). Durability heat pipe No.5 had a high temperature bakeout and reflux cleaning and showed low levels of wick corrosion after long-term operation. After testing durability heat pipe No.6 for 5,003 hours at an operating temperature of 750 C, it showed low levels of wick corrosion. This test shows a high temperature bakeout alone will significantly reduce wick corrosion without the need for costly and time consuming reflux cleaning.

  10. Preliminary evaluation of resinite recovery from Illinois coal. [Quarterly] technical report, September 1--November 30, 1994

    SciTech Connect (OSTI)

    Crelling, J.C.

    1994-12-31

    Resinite is a naturally occurring substance found in coal and derived from original plant resins. It is ubiquitous in North American coals. It makes up one to four percent by volume of most Illinois coals. It has been commercially exploited in the western USA for use in adhesives, varnishes and thermal setting inks. The overall objective of this project is to compare the properties of the resinite contained in Illinois Basin coals to resinite being commercially exploited in the western United States, and to recover the resinite from Illinois coals by microbubble column floatation techniques. The significance of this study is that it has the potential to show the way to recover a valuable chemical, resinite, from coal using only physical processing techniques. The value of the resinite at $1.00/kg or $0.50/lb makes it about fifty times more valuable than steam coal. The removal of resinite from coal does not decrease the value of the remaining coal in any way. The unique aspects are that: (1) it is the first examination of the resinite recovery potential of Illinois coal, (2) it integrates the latest characterization techniques such as density Gradient centrifugation, microspectrofluorometry, and gas chromatography- mass spectrometry, and (3) it uses microbubble column flotation to determine the resinite recovery potential. During this quarter samples were obtained, information from both the databases of both the Illinois State Geological Survey (ISGS) and the Pennsylvania State University (PSU) was obtained and evaluated, and EBCSP samples from the Herrin No. 6, the Springfield No. 5 and the Colchester No. 2 seams were analyzed petrographically and the resinites in these samples were characterized by fluorescence spectral analysis.

  11. Preliminary evaluation of resinite recovery from Illinois coal. Technical report, December 1, 1994--February 28, 1995

    SciTech Connect (OSTI)

    Crelling, J.C.

    1995-12-31

    Resinite is a naturally occurring substance found in coal and derived from original plant resins. It is ubiquitous in North American coals. It makes up one to four percent by volume of most Illinois coals. It has been commercially exploited in the western USA for use in adhesives, varnishes and thermal setting inks. The overall objective of this project is to compare the properties of the resinite contained in Illinois Basin coals to resinite being commercially exploited in the western United States, and to recover the resinite from Illinois coals by microbubble column floatation techniques. This project is relevant to priority 1.4A identified in ICCI/RFP93-1. The significance of this study is that it has the potential to show the way to recover a valuable chemical, resinite, from coal using only physical processing techniques. The value of the resinite at $1.00/kg or $0.50/lb makes it about fifty times more valuable than steam coal. The removal of resinite from coal does not decrease the value of the remaining coal in any way. The unique aspects are that: (1) it is the first examination of the resinite recovery potential of Illinois coal, (2) it integrates the latest characterization techniques such as density gradient centrifugation, microspectrofluorometry, and gas chromatography-mass spectrometry, and (3) it uses microbubble column flotation to determine the resinite recovery potential. During this quarter samples were obtained, information from both the databases of both the Illinois State Geological Survey (ISGS) and the Pennsylvania State University (PSU) was obtained and evaluated, and IBCSP samples from the Herrin No. 6, the Springfield No. 5 and the Colchester No. 2 seams were analyzed petrographically and the resinites in these samples were characterized by fluorescence spectral analysis.

  12. Pilot-Scale Demonstration of Pefi's Oxygenated Transportation Fuels Production Technology

    SciTech Connect (OSTI)

    2005-05-01

    Coal-cleaning processes have been utilized to increase the heating value of coal by extracting ash-forming minerals in the coal. These processes involve the crushing or grinding of raw coal followed by physical separation processes, taking advantage of the density difference between carbonaceous particles and mineral particles. In addition to the desired increase in the heating value of coal, a significant reduction of the sulfur content of the coal fed to a combustion unit is effected by the removal of pyrite and other sulfides found in the mineral matter. WRI is assisting PulseWave to develop an alternate, more efficient method of liberating and separating the undesirable mineral matter from the carbonaceous matter in coal. The approach is based on PulseWave's patented resonance disintegration technology that reduces that particle size of materials by application of destructive resonance, shock waves, and vortex generating forces. Illinois No.5 coal, a Wyodak coal, and a Pittsburgh No.8 coal were processed using the resonance disintegration apparatus then subjected to conventional density separations. Initial microscopic results indicate that up to 90% of the pyrite could be liberated from the coal in the machine, but limitations in the density separations reduced overall effectiveness of contaminant removal. Approximately 30-80% of the pyritic sulfur and 30-50% of the mercury was removed from the coal. The three coals (both with and without the pyritic phase separated out) were tested in WRI's 250,000 Btu/hr Combustion Test Facility, designed to replicate a coal-fired utility boiler. The flue gases were characterized for elemental, particle bound, and total mercury in addition to sulfur. The results indicated that pre-combustion cleaning could reduce a large fraction of the mercury emissions.

  13. Fabrication of full-scale fiber-reinforced hot-gas filters by chemical vapor depostion. Final report, November 1, 1994 -- December 32, 1995

    SciTech Connect (OSTI)

    Smith, R.G.; Eaton, J.H.; Pysher, D.J.; Leitheiser, M.A.

    1996-01-01

    The overall goal of this contract and its extensions has been to develop a hot gas candle filter which is light weight, has a thin wall, resists mechanical and thermal shock, and is resistive to alkali attack. A ceramic fiber reinforced, ceramic matrix composite approach has been followed to fabricate this new candle filter. Past reports covered the first test results of two ceramic composite candle filters at the Westinghouse Science and Technology Center in March of 1993, subsequent improvements made in the filters construction and fabrication processing, and the testing of six improved full size, 60 mm diameter by 1575 mm length, filters that met or exceeded performance requirements set for them. Completion of the 172 hours of simulated PFBC testing and thermal transients plus maintaining less than 4 ppm clean side ash concentration provided a basis for moving to the next step of testing in the Tidd PFBCC Demonstration Project. In this contract extension 3M fabricated 110 filters to be used for tests in demonstration power plant facilities and other tests that become available. The filters were tested to meet all quality assurance specifications and inventoried for Oak Ridge National Laboratory, ORNL. The filters are being shipped to various industrial, university, and national laboratory test facilities as requested by ORNL. Ten ceramic composite filters were installed in December, 1994 in the Tidd PFBC Demonstration Project filter vessel for their test period No. 5. Five filters were installed in a top cluster and five in a bottom cluster. The filters were removed in May 1995 after operating for 1 1 1 0 hours in a temperature range of 760{degrees}C to 843{degrees}C, with 80% of the run above 815{degrees}C.

  14. The selective catalytic reduction of NOx over Ag/Al2O3 with isobutanol as the reductant

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Brookshear, Daniel William; Pihl, Josh A.; Toops, Todd J.; West, Brian H.; Prikhodko, Vitaly Y.

    2016-02-13

    Here, this study investigates the potential of isobutanol (iBuOH) as a reductant for the selective catalytic reduction (SCR) of NOx over 2 wt% Ag/Al2O3 between 150 and 550 °C and gas hourly space velocities (GHSV) between 10,000 and 35,000 h-1. The feed gas consists of 500 ppm NO, 5% H2O, 10% O2, and 375-1500 ppm iBuOH (C1:N ratios of 3-12); additionally, blends of 24 and 48% iBuOH in gasoline are evaluated. Over 90% NOx conversion is achieved between 300 and 400 C using pure iBuOH, including a 40% peak selectivity towards NH3 that could be utilized in a dual HC/NH3more » SCR configuration. The iBuOH/gasoline blends are only able to achieve greater than 90% NOx conversion when operated at a GHSV of 10,000 h-1 and employing a C1:N ratio of 12. Iso-butyraldehyde and NO2 appear to function as intermediates in the iBuOH-SCR mechanism, which mirrors the mechanism observed for EtOH-SCR. In general, the performance of iBuOH in the SCR of NOx over a Ag/Al2O3 catalyst is comparable with that of EtOH, although EtOH/gasoline blends display higher NOx reduction than iBuOH/gasoline blends. The key parameter in employing alcohols in SCR appears to be the C-OH:N ratio rather than the C1:N ratio.« less

  15. Nucleic and amino acid sequences relating to a novel transketolase, and methods for the expression thereof

    DOE Patents [OSTI]

    Croteau, Rodney Bruce; Wildung, Mark Raymond; Lange, Bernd Markus; McCaskill, David G.

    2001-01-01

    cDNAs encoding 1-deoxyxylulose-5-phosphate synthase from peppermint (Mentha piperita) have been isolated and sequenced, and the corresponding amino acid sequences have been determined. Accordingly, isolated DNA sequences (SEQ ID NO:3, SEQ ID NO:5, SEQ ID NO:7) are provided which code for the expression of 1-deoxyxylulose-5-phosphate synthase from plants. In another aspect the present invention provides for isolated, recombinant DXPS proteins, such as the proteins having the sequences set forth in SEQ ID NO:4, SEQ ID NO:6 and SEQ ID NO:8. In other aspects, replicable recombinant cloning vehicles are provided which code for plant 1-deoxyxylulose-5-phosphate synthases, or for a base sequence sufficiently complementary to at least a portion of 1-deoxyxylulose-5-phosphate synthase DNA or RNA to enable hybridization therewith. In yet other aspects, modified host cells are provided that have been transformed, transfected, infected and/or injected with a recombinant cloning vehicle and/or DNA sequence encoding a plant 1-deoxyxylulose-5-phosphate synthase. Thus, systems and methods are provided for the recombinant expression of the aforementioned recombinant 1-deoxyxylulose-5-phosphate synthase that may be used to facilitate its production, isolation and purification in significant amounts. Recombinant 1-deoxyxylulose-5-phosphate synthase may be used to obtain expression or enhanced expression of 1-deoxyxylulose-5-phosphate synthase in plants in order to enhance the production of 1-deoxyxylulose-5-phosphate, or its derivatives such as isopentenyl diphosphate (BP), or may be otherwise employed for the regulation or expression of 1-deoxyxylulose-5-phosphate synthase, or the production of its products.

  16. Final Technical Report for project "Factors Controlling In Situ Uranium and Technetium Bio-Reduction and Reoxidation at the NABIR Field Research Center"

    SciTech Connect (OSTI)

    Dr. Jonathan D. Istok , Oregon State University; Dr. Lee Krumholz, University of Oklahoma; Dr. James McKinley, Pacific Northwest National Laboratory; Dr. Baohua Gu, Oak Ridge National Laboratory

    2006-10-31

    The overall goal of this project was to better understand factors and processes controlling microbially-mediated reduction and reoxidation of U and Tc in the unconsolidated residuum overlying the Nolichucky shale at the Field Research Center (FRC) at Oak Ridge National Laboratory. Project activities were designed to test the following hypotheses: 1. The small rates of denitrification and U bio-reduction observed in laboratory incubations of sediments from FRC Area 1 at low pH (< 5) are due to the presence of high concentrations of toxic metals (especially Al and Ni). Rates of Tc reduction will also be small at low pH in the presence of high concentrations of toxic metals. 2. In situ rates of U and perhaps Tc bio-reduction can be increased by increasing system pH and thus precipitating toxic metals from solution. 3. In situ rates of U and Tc bio-reduction can be increased by the addition of humic substances, which complex toxic metals such as Al and Ni, buffer pH, and serve as electron shuttles to facilitate U and Tc reduction. 4. Microbially-reduced U and Tc are rapidly oxidized in the presence of high concentrations of NO3- and the denitrification intermediates NO2-, N2O, and NO. 5. An electron-donor-addition strategy (type and form of donor, with or without pH adjustment and with or without the co-addition of humic substances) can be devised to reduce U and Tc concentrations for an extended period of time in low pH groundwater in the presence of high concentrations of NO3-, Al, and Ni. This strategy operates by removing or complexing these components of FRC groundwater to allow the subsequent reduction of U(VI) and Tc(VII).

  17. Demonstration of the enrichment of medium quality gas from gob wells through interactive well operating practices. Final report, June--December, 1995

    SciTech Connect (OSTI)

    Blackburn, S.T.; Sanders, R.G.; Boyer, C.M. II; Lasseter, E.L.; Stevenson, J.W.; Mills, R.A.

    1995-12-01

    Methane released to the atmosphere during coal mining operations is believed to contribute to global warming and represents a waste of a valuable energy resource. Commercial production of pipeline-quality gob well methane through wells drilled from the surface into the area above the gob can, if properly implemented, be the most effective means of reducing mine methane emissions. However, much of the gas produced from gob wells is vented because the quality of the gas is highly variable and is often below current natural gas pipeline specifications. Prior to the initiation of field-testing required to further understand the operational criteria for upgrading gob well gas, a preliminary evaluation and assessment was performed. An assessment of the methane gas in-place and producible methane resource at the Jim Walter Resources, Inc. No. 4 and No. 5 Mines established a potential 15-year supply of 60 billion cubic feet of mien methane from gob wells, satisfying the resource criteria for the test site. To understand the effect of operating conditions on gob gas quality, gob wells producing pipeline quality (i.e., < 96% hydrocarbons) gas at this site will be operated over a wide range of suction pressures. Parameters to be determined will include absolute methane quantity and methane concentration produced through the gob wells; working face, tailgate and bleeder entry methane levels in the mine; and the effect on the economics of production of gob wells at various levels of methane quality. Following this, a field demonstration will be initiated at a mine where commercial gob gas production has not been attempted. The guidelines established during the first phase of the project will be used to design the production program. The economic feasibility of various utilization options will also be tested based upon the information gathered during the first phase. 41 refs., 41 figs., 12 tabs.

  18. Dialogs on the Yucca Mountain controversy. Special report No. 10

    SciTech Connect (OSTI)

    Schluter, C.M.; Szymanski, J.S.

    1993-08-01

    In an attempt to resolve the controversial issue of tectonic and hydrologic stability of the Yucca Mountain region, the National Academy of Sciences established a Panel on Coupled Hydrologic/Tectonic/HydrothermaI Systems. The Panel has recently released it`s findings in a report entitled Ground Water at Yucca Mountain: How High Can It Rise? The representation of data and the scientific validity of this report was the subject of comprehensive evaluations and reviews which has led to correspondence between Dr. Charles Archarnbeau and Dr. Frank Press, the President of the National Academy of Sciences. All such correspondence prior to April 9, 1993 is covered by TRAC Special Report No. 5, {open_quotes}Dialogs on the Yucca Mountain Controversy.{close_quotes} The present report represents a continuation of the dialog between Dr. Archambeau and Dr. Press; specifically the letter from Dr. Press to Dr. Archambeau dated April 9, 1993 and Archambeau`s response to Press, dated August 19, 1993. In addition to the correspondence between Press and Archambeau, a series of recent reports by other investigators, referred to in the correspondence from Archambeau, are included in this report and document new data and inferences of importance for resolution of the question of suitability of the Yucca Mountain site as a high level nuclear waste repository. These reports also demonstrate that other scientists, not previously associated with the government`s program at Yucca Mountain or the National Academy review of an aspect of that program, have arrived at conclusions that are different than those stated by the Academy review and DOE program scientists.

  19. Method for sequential injection of liquid samples for radioisotope separations

    DOE Patents [OSTI]

    Egorov, Oleg B.; Grate, Jay W.; Bray, Lane A.

    2000-01-01

    The present invention is a method of separating a short-lived daughter isotope from a longer lived parent isotope, with recovery of the parent isotope for further use. Using a system with a bi-directional pump and one or more valves, a solution of the parent isotope is processed to generate two separate solutions, one of which contains the daughter isotope, from which the parent has been removed with a high decontamination factor, and the other solution contains the recovered parent isotope. The process can be repeated on this solution of the parent isotope. The system with the fluid drive and one or more valves is controlled by a program on a microprocessor executing a series of steps to accomplish the operation. In one approach, the cow solution is passed through a separation medium that selectively retains the desired daughter isotope, while the parent isotope and the matrix pass through the medium. After washing this medium, the daughter is released from the separation medium using another solution. With the automated generator of the present invention, all solution handling steps necessary to perform a daughter/parent radionuclide separation, e.g. Bi-213 from Ac-225 "cow" solution, are performed in a consistent, enclosed, and remotely operated format. Operator exposure and spread of contamination are greatly minimized compared to the manual generator procedure described in U.S. patent application Ser. No. 08/789,973, now U.S. Pat. No. 5,749,042, herein incorporated by reference. Using 16 mCi of Ac-225 there was no detectable external contamination of the instrument components.

  20. Use of Biostratigraphy to Increase Production, Reduce Operating Costs and Risks and Reduce Environmental Concerns in Oil Well Drilling

    SciTech Connect (OSTI)

    Edward Marks

    2005-09-09

    In the Santa Maria Basin, Santa Barbara County, California, four wells were processed and examined to determine the age and environment parameters in the oil producing sections. From west to east, we examined Cabot No. 1 Ferrero-Hopkins,from 3917.7 m (12850 ft) to 4032 m (13225 ft); Sun No. 5 Blair, from 3412 m (11190 ft) to 3722.5 m (12210 ft); Triton No. 10 Blair, from 1552 m (5090 ft) to 1863 m (6110 ft); and OTEC No. 1 Boyne, from 2058 m (6750 ft) to 2528 m (8293 ft). Lithic reports with lithic charts were prepared and submitted on each well. These tested for Sisquoc Fm lithology to be found in the Santa Maria area. This was noted in the OTEC No. 1 Boyne interval studied. The wells also tested for Monterey Fm. lithology, which was noted in all four wells examined. Composite samples of those intervals [combined into 9.15 m (30 foot) intervals] were processed for paleontology. Although the samples were very refractory and siliceous, all but one (Sun 5 Blair) yielded index fossil specimens, and as Sun 5 Blair samples below 3686 m (12090 ft) were processed previously, we were able to make identifications that would aid this study. The intervals examined were of the Sisquoc Formation, the Low Resistivity and the High Resistivity sections of the Monterey Formation. The Lower Sisquoc and the top of the late Miocene were identified by six index fossils: Bolivina barbarana, Gyroidina soldanii rotundimargo, Bulimina montereyana, Prunopyle titan, Axoprunum angelinum and Glyphodiscus stellatus. The Low Resistivity Monterey Fm. was identified by eight index fossils, all of which died out at the top of the late Miocene, late Mohnian: Nonion goudkoffi, Brizalina girardensis, Cibicides illingi, Siphocampe nodosaria, Stephanogonia hanzawai, Uvigerina modeloensis, Buliminella brevior, Tytthodiscus sp.and the wide geographic ranging index pelagic fossil, Sphaeroidinellopsis subdehiscens. The High Resistivity Monterey Fm. was identified by eight index fossils, all of which died out at the top of the late Miocene, early Mohnian: Bolivina aff hughesi, Rotalia becki, Suggrunda californica, Virgulina grandis, Virgulina ticensis, Bulimina ecuadorana, Denticula lauta and Nonion medio-costatum. Please see Appendix B, Fig. 1, Neogene Zones, p. 91 and Appendix C, chart 5, p. 99 By the use of Stratigraphy, employing both Paleontology and Lithology, we can increase hydrocarbon production, reduce operating costs and risks by the identification of the productive sections, and reduce environmental concerns by drilling less dry holes needlessly.

  1. HYBRID SELECTIVE NON-CATALYTIC REDUCTION (SNCR)/SELECTIVE CATALYTIC REDUCTION (SCR) DEMONSTRATION FOR THE REMOVAL OF NOx FROM BOILER FLUE GASES

    SciTech Connect (OSTI)

    Jerry B. Urbas

    1999-05-01

    The U. S. Department of Energy (DOE), Electric Power Research Institute (EPRI), Pennsylvania Electric Energy Research Council, (PEERC), New York State Electric and Gas and GPU Generation, Inc. jointly funded a demonstration to determine the capabilities for Hybrid SNCR/SCR (Selective Non-Catalytic Reduction/Selective Catalytic Reduction) technology. The demonstration site was GPU Generation's Seward Unit No.5 (147MW) located in Seward Pennsylvania. The demonstration began in October of 1997 and ended in December 1998. DOE funding was provided through Grant No. DE-FG22-96PC96256 with T. J. Feeley as the Project Manager. EPRI funding was provided through agreements TC4599-001-26999 and TC4599-002-26999 with E. Hughes as the Project Manager. This project demonstrated the operation of the Hybrid SNCR/SCR NO{sub x} control process on a full-scale coal fired utility boiler. The hybrid technology was expected to provide a cost-effective method of reducing NO{sub x} while balancing capital and operation costs. An existing urea based SNCR system was modified with an expanded-duct catalyst to provide increased NO{sub x} reduction efficiency from the SNCR while producing increased ammonia slip levels to the catalyst. The catalyst was sized to reduce the ammonia slip to the air heaters to less than 2 ppm while providing equivalent NO{sub x} reductions. The project goals were to demonstrate hybrid technology is capable of achieving at least a 55% reduction in NO{sub x} emissions while maintaining less than 2ppm ammonia slip to the air heaters, maintain flyash marketability, verify the cost benefit and applicability of Hybrid post combustion technology, and reduce forced outages due to ammonium bisulfate (ABS) fouling of the air heaters. Early system limitations, due to gas temperature stratification, restricted the Hybrid NO{sub x} reduction capabilities to 48% with an ammonia slip of 6.1 mg/Nm{sup 3} (8 ppm) at the catalyst inlet. After resolving the stratification problem, the catalyst did not have sufficient activity in order to continue the planned test program. Arsenic poisoning was found to be the cause of premature catalyst deactivation.

  2. ADVANCED TURBINE SYSTEMS PROGRAM

    SciTech Connect (OSTI)

    Gregory Gaul

    2004-04-21

    Natural gas combustion turbines are rapidly becoming the primary technology of choice for generating electricity. At least half of the new generating capacity added in the US over the next twenty years will be combustion turbine systems. The Department of Energy has cosponsored with Siemens Westinghouse, a program to maintain the technology lead in gas turbine systems. The very ambitious eight year program was designed to demonstrate a highly efficient and commercially acceptable power plant, with the ability to fire a wide range of fuels. The main goal of the Advanced Turbine Systems (ATS) Program was to develop ultra-high efficiency, environmentally superior and cost effective competitive gas turbine systems for base load application in utility, independent power producer and industrial markets. Performance targets were focused on natural gas as a fuel and included: System efficiency that exceeds 60% (lower heating value basis); Less than 10 ppmv NO{sub x} emissions without the use of post combustion controls; Busbar electricity that are less than 10% of state of the art systems; Reliability-Availability-Maintainability (RAM) equivalent to current systems; Water consumption minimized to levels consistent with cost and efficiency goals; and Commercial systems by the year 2000. In a parallel effort, the program was to focus on adapting the ATS engine to coal-derived or biomass fuels. In Phase 1 of the ATS Program, preliminary investigators on different gas turbine cycles demonstrated that net plant LHV based efficiency greater than 60% was achievable. In Phase 2 the more promising cycles were evaluated in greater detail and the closed-loop steam-cooled combined cycle was selected for development because it offered the best solution with least risk for achieving the ATS Program goals for plant efficiency, emissions, cost of electricity and RAM. Phase 2 also involved conceptual ATS engine and plant design and technology developments in aerodynamics, sealing, combustion, cooling, materials, coatings and casting development. The market potential for the ATS gas turbine in the 2000-2014 timeframe was assessed for combined cycle, simple cycle and integrated gasification combined cycle, for three engine sizes. The total ATS market potential was forecasted to exceed 93 GW. Phase 3 and Phase 3 Extension involved further technology development, component testing and W501ATS engine detail design. The technology development efforts consisted of ultra low NO{sub x} combustion, catalytic combustion, sealing, heat transfer, advanced coating systems, advanced alloys, single crystal casting development and determining the effect of steam on turbine alloys. Included in this phase was full-load testing of the W501G engine at the McIntosh No. 5 site in Lakeland, Florida.

  3. RP-5 Renewable Energy Efficiency Project

    SciTech Connect (OSTI)

    Neil Clifton; Dave Wall; Jamal Zughbi

    2007-06-30

    This is the final technical report for the RP-5 Renewable Energy Efficiency Project (REEP). The report summarizes, in a comprehensive manner, all the work performed during the award period extending between July 12, 2002 and June 30, 2007. This report has been prepared in accordance with the Department of Energy (DOE) Guidelines and summarizes all of the activities that occurred during the award period. The RP-5 Renewable Energy Efficiency Project, under development by the Inland Empire Utilities Agency (IEUA), is comprised of a series of full-scale demonstration projects that will showcase innovative combinations of primary and secondary generation systems using methane gas derived from local processing of biosolids, dairy manure and other organic material. The goal of the project is to create renewable energy-based generation systems with energy efficiencies 65% or more. The project was constructed at the 15 MGD Regional Wastewater Treatment Plant No. 5 located in the City of Chino in California where the Agency has constructed its new energy-efficient (platinum-LEED rating) headquarters building. Technologies that were featured in the project include internal combustion engines (ICE), absorption chillers, treatment plant secondary effluent cooling systems, heat recovery systems, thermal energy storage (TES), Organic Rankine Cycle (ORC) secondary power generation system, the integration of a future fuel cell system, gas cleaning requirements, and other state-of-the-art design combinations. The RP-5 REEP biogas source is coming from three manure digesters which are located within the RP-5 Complex and are joined with the RP-5 REEP through gas conveyance pipelines. Food waste is being injected into the manure digesters for digester gas production enhancement. The RP-5 REEP clearly demonstrates the biogas production and power generation viability, specifically when dealing with renewable and variable heating value (Btu) fuel. The RP-5 REEP was challenged with meeting stringent utility, gas, power, and air quality rules and regulations. Coordination with the Southern California Gas Company (SCGC), Southern California Edison (SCE), and South Coast Air Quality Management District (SCAQMD) was continuous and extensive. The interconnecting agreement and the permit to construct and operate were major obstacles despite the early start and coordination with the utility companies and regulatory agencies. The RP-5 REEP is part of a unique RP-5 Complex approach where several facilities are tied and connected with each other; where energy and gas can be transferred from one facility to another (see attached RP-5 Complex Ultimate Energy Balance Diagram). The REEP also incorporated new technologies, such as TES and ORC, along with using heat recovery for the platinum-LEED headquarter buildings heating and cooling via efficient absorption chillers. Through the conceptual design phase, numerous innovative technologies were researched and evaluated, with the most proven and efficient selected to be part of the RP-5 REEP.

  4. DIRECT MEASUREMENT OF MERCURY REACTIONS IN COAL POWER PLANT PLUMES

    SciTech Connect (OSTI)

    Leonard Levin

    2006-06-01

    This project was awarded under U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) Program Solicitation DE-PS26-02NT41422 and specifically addresses Program Area of Interest: No.5--Environmental and Water Resources. The project team includes the Electric Power Research Institute (EPRI) as the contractor and the University of North Dakota Energy & Environmental Research Center (EERC) and Frontier Geosciences as subcontractors. Wisconsin Energies and its Pleasant Prairie Power Plant acted as host for the field-testing portion of the research. The project is aimed at clarifying the role, rates, and end results of chemical transformations that may occur to mercury that has been emitted from elevated stacks of coal-fired electric power plants. Mercury emitted from power plants emerges in either its elemental, divalent, or particulate-bound form. Deposition of the divalent form is more likely to occur closer to the source than that of the other two forms, due to its solubility in water. Thus, if chemical transformations occur in the stack emissions plume, measurements in the stack may mischaracterize the fate of the material. Initial field and pilot plant measurements have shown significant and rapid chemical reduction of divalent to elemental mercury may occur in these plumes. Mercury models currently assume that the chemical form of mercury occurring in stacks is the same as that which enters the free atmosphere, with no alteration occurring in the emissions plume. Recent data indicate otherwise, but need to be evaluated at full operating scale under field conditions. Prestbo and others have demonstrated the likelihood of significant mercury chemical reactions occurring in power plant plumes (Prestbo et al., 1999; MDNR-PPRP, 2000; EERC, 2001). This experiment will thus increase our understanding of mercury atmospheric chemistry, allowing informed decisions regarding source attribution. The experiment was carried out during the period August 22-September 5, 2003. The experimental site was the Pleasant Prairie Power Plant in Pleasant Prairie, Wisconsin, just west of Kenosha. The experiment involved using an aircraft to capture emissions and document chemistry changes in the plume. While using the airplane for sampling, supplemental fast-response sensors for NOx, connected to data loggers, were used to gauge entry and exit times and transect intervals through plume emissions material. The Frontier Geosciences Static Plume Dilution Chamber (SPDC) was employed simultaneously adjacent to the stack to correlate its findings with the aircraft sampling, as well as providing evaluation of the SPDC as a rapid, less costly sampler for mercury chemistry. A complementary stack plume method, the Dynamic Plume Dilution (DPD) was used in the latter portion of the experiment to measure mercury speciation to observe any mercury reduction reaction with respect to both the reaction time (5 to 30 seconds) and dilution ratio. In addition, stack sampling using the ''Ontario Hydro'' wet chemistry method and continuous mercury monitors (CMM) were used to establish the baseline chemistry in the stack. Comparisons among stack, SPDC, DPD and aircraft measurements allow establishment of whether significant chemical changes to mercury occur in the plume, and of the verisimilitude of the SPDC and DPD methods. This progress report summarizes activities during a period of results review from the stack/aircraft subcontractor, data analysis and synthesis, and preparation and presentation of preliminary results to technical and oversight meetings.

  5. Worksheet

    U.S. Energy Information Administration (EIA) Indexed Site

    UTILITY_ID","UTILITY_NAME","TRANSLINE_NO","TERMINAL_LOC_FROM","TERMINAL_LOC_TO","PERCENT_OWNED","LINE_LENGTH","LINE_TYPE","VOLTAGE_TYPE","VOLTAGE_OPERATING","VOLTAGE_DESIGN","CONDUCTOR_SIZE","CONDUCTOR_MAT_TYPE","CONDUCTOR_CONFIG","CIRCUIT_PERSTRUCT_PRES","CIRCUIT_PERSTRUCT_ULT","POLE_TOWER_TYPE","RATED_CAPACITY","LAND_LANDRIGHT_COSTS","POLE_TOWER_FIXTURE_COSTS","CONDUCTOR_DEVICE_COSTS","CONSTRUCTION_ETC_COSTS","TOTAL_LINE_COSTS","IN_SERVICE_DATE" 2003,1015,"Austin City of",1,"Northland","Magnesium Plant",100,4.11,"OH","AC",138,138,795,"ACSR Drake/ACSS Rail","Single",1,2,"Steel & Wood Poles",215,0,17500,8000,19500,45000,"application/vnd.ms-excel" 2003,1015,"Austin City of",2,"Grove","Met Center",100,3.1,"OH","AC",138,138,795,"ASCR Drake","Double",1,1,"Steel Pole",430,0,30000,10000,35000,75000,"application/vnd.ms-excel" 2003,1015,"Austin City of",3,"Dessau","Daffin Gin",100,6.01,"OH","AC",138,138,795,"ASCR Drake","Single",1,1,"Steel Pole",215,0,60000,15000,40000,115000,"application/vnd.ms-excel" 2003,1015,"Austin City of",4,"Burleson","AMD",100,2.2,"OH","AC",138,138,795,"ACR Drake","Double",2,2,"Steel Pole",430,0,75000,55000,120000,250000,"application/vnd.ms-excel" 2003,1015,"Austin City of",5,"Bergstrom","Kingsberry",100,4.2,"OH","AC",138,138,795,"ASCR Drake/AAAC","Single",1,2,"Steel & Wood Poles",215,0,75000,35000,340000,450000,"application/vnd.ms-excel" 2003,1015,"Austin City of",6,"Mcneil","Magnesium Plant",100,3.24,"OH","AC",138,138,795,"ACSR Drake","Double",1,2,"Steel Pole & Steel Tower",430,0,380000,76000,644000,1100000,"application/vnd.ms-excel" 2003,1015,"Austin City of",7,"Summit","Magnesium Plant",100,2.18,"OH","AC",138,138,795,"ACSR Drake","Double",1,2,"Steel Pole & Steel Tower",430,0,265000,125000,410000,800000,"application/vnd.ms-excel" 2003,1307,"Basin Electric Power Coop",1,"Rapid City","New Underwood",65,18.55,"OH","AC",230,230,1272,"ACSR","Single",1,1,"Single Pole, Steel",460,0,0,0,5300000,5300000,"application/vnd.ms-excel" 2003,1586,"Bentonville City of",1,"AEP/SWEPCO","City Substation F",100,1,"OH","AC",161,161,477,"ACSR","Single",1,1,"Wood and Steel Single Pole",199,18000,81522,28082,214516,342120,"application/vnd.ms-excel" 2003,2172,"Brazos Electric Power Coop",1,"Coppell","Lewisville",100,7.03,"OH","AC",138,138,1033,"ACSR","Double",1,1,"Concrete/Steel Single Pole",485,17577.55,2527717,537265.96,956475.39,4039035.9,"application/vnd.ms-excel" 2003,2172,"Brazos Electric Power Coop",2,"Boyd","Newark",100,1.8,"OH","AC",138,138,795,"ACSR","Single",2,2,"Concrete/Steel Single Pole",215,133929.08,538282.3,131112.75,246577.6,1049901.73,"application/vnd.ms-excel" 2003,2172,"Brazos Electric Power Coop",3,"Cedar Hill","Sardis",100,5.1,"OH","AC",138,138,795,"ACSR","Single",1,1,"Concrete Si ngle Ploe",215,24515.26,652910.22,246676.96,560582.43,1484684.87,"application/vnd.ms-excel" 2003,5580,"East Kentucky Power Coop Inc",1,"Jamestown Tap","Jamestown Tap",100,0.47,"OH","AC",161,161,556.5,"ACSR","Single",1,1,"Wood Single Pole",292,43326,160508,68789,0,272623,"application/vnd.ms-excel" 2003,5580,"East Kentucky Power Coop Inc",2,"Pulaski Co. Tap","Pulaski Co. Tap",100,5.88,"OH","AC",161,161,795,"ACSR","Single",1,1,"Wood H-Frame Structure",367,494183,1092462,468198,0,2054843,"application/vnd.ms-excel" 2003,7197,"Georgia Transmission Corp",1,"Shoal Creek","Spout Spring",100,10.83,"OH","AC",230,230,1351,"ACSR","Single",1,1,"Concrete, Single Pole & Steel",602,1277945,1685271,444690,6047603,9455509,"application/vnd.ms-excel" 2003,7197,"Georgia Transmission Corp",2,"Dresden","Yellowdirt",100,9.5,"OH","AC",230,230,795,"ACSR","Double",1,1,"Concrete, Single Pole",866,870826,772876,375515,3649376,5668593,"application/vnd.ms-excel" 2003,7197,"Georgia Transmission Corp",3,"East Moultrie","West Valdosta",100,38.46,"OH","AC",230,230,1622,"ACSR","Single",1,1,"Concrete, Single Pole",596,1191168,2829632,1476802,10279078,15776680,"application/vnd.ms-excel" 2003,7490,"Grand River Dam Authority",1,"Cowskin","Grove PSO",100,4.5,"OH","AC",138,138,795,"ACSR","Single/Twisted",1,1,"Wood Pole",223,287671,135402,156769,880890,1460732,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",1,"BASTROP","AUSTIN",100,0.32,"OH","AC",138,138,795,"ACSR","Single",1,1,"Wood Pole",,9155828,155817297,37044659,47228709,249246493,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",2,"BASTROP","AUSTROP",100,0.32,"OH","AC",138,138,795,"ACSR","Single",1,1,"Wood Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",3,"BASTROP","AUSTROP",100,0.32,"OH","AC",138,138,795,"ACSR","Single",1,1,"Wood Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",4,"BASTROP","AUSTROP",100,0.32,"OH","AC",138,138,795,"ACSR","Single",1,1,"Wood Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",5,"CANYON","SAN MARCOS/LOCKHART",100,0.31,"OH","AC",138,138,795,"ACSR","Single",1,1,"Wood Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",6,"CANYON","SAN MARCOS/LOCKHART",100,0.31,"OH","AC",138,138,795,"ACSR","Single",1,1,"Wood Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",7,"CANYON","SAN MARCOS/LOCKHART",100,0.31,"OH","AC",138,138,795,"ACSR","Single",1,1,"Wood Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",8,"CANYON","SAN MARCOS/LOCKHART",100,0.31,"OH","AC",138,138,795,"ACSR","Single",1,1,"Wood Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",9,"CANYON","SAN MARCOS/LOCKHART",100,0.31,"OH","AC",138,138,795,"ACSR","Single",1,1,"Wood Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",10,"CICO","HELOTES",100,4,"OH","AC",138,138,795,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",11,"CICO","HELOTES",100,4,"OH","AC",138,138,795,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",12,"CICO","HELOTES",100,4,"OH","AC",138,138,795,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",13,"CICO","HELOTES",100,4,"OH","AC",138,138,795,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",14,"CICO","HELOTES",100,4,"OH","AC",138,138,795,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",15,"CICO","HELOTES",100,4,"OH","AC",138,138,795,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",16,"LOCKHART","DUMP HILL",100,1.6,"OH","AC",138,138,795,"ACSR","Single",1,1,"Concrete Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",17,"HILL POWER STATION","NUECES BAY",100,17.3,"OH","AC",138,138,795,"ACSR","Double",1,1,"Wood Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",18,"NORTH OAK PARK","LON HILL",100,14.9,"OH","AC",138,138,795,"ACSR","Double",1,1,"Wood Pole",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",19,"STATE HIGHTWAY 80",,100,0.38,"OH","AC",138,138,211.5,"ACSR","Single",1,1,"Wood H-Frame Structure",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",20,"STATE HIGHWAY 80",,100,0.38,"OH","AC",138,138,211.5,"ACSR","Single",1,1,"Wood H-Frame Structure",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",21,"STERLING/MITCHELL LINE","TWINN BUTTES",100,135.08,"OH","AC",345,345,1590,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",22,"VERDE CREEK","KERRVILLE STADIUM",100,0.1,"OH","AC",138,138,336,"ACSR","Double",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",23,"VERDE CREEK","KERRVILLE STADIUM",100,0.1,"OH","AC",138,138,336,"ACSR","Double",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",24,"VERDE CREEK","KERRVILLE STADIUM",100,0.1,"OH","AC",138,138,336,"ACSR","Double",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",25,"VERDE CREEK","KERRVILLE STADIUM",100,0.1,"OH","AC",138,138,336,"ACSR","Double",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",26,"ZORN","MCCARTY LANE",100,4.2,"OH","AC",138,138,1433.6,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",27,"ZORN","MCCARTY LANE",100,4.2,"OH","AC",138,138,1433.6,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",28,"ZORN","MCCARTY LANE",100,4.2,"OH","AC",138,138,1433.6,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",29,"ZORN","MCCARTY LANE",100,4.2,"OH","AC",138,138,1433.6,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",30,"ZORN","MCCARTY LANE",100,4.2,"OH","AC",138,138,1433.6,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,11269,"Lower Colorado River Authority",31,"ZORN","MCCARTY LANE",100,4.2,"OH","AC",138,138,1433.6,"ACSR","Single",1,1,"Steel Tower",,0,0,0,0,0,"application/vnd.ms-excel" 2003,15143,"Platte River Power Authority",1,"Rawhide","Timberline West",100,31.63,"OH","AC",230,230,954,"ACSR","Single",2,2,"Steel/Tower & Pole",378,5553,1928767,2385430,251850,4571600,"application/vnd.ms-excel" 2003,15159,"Plymouth City of",1,"Mullet River Sub","Sub # 1",100,0.8,"OH","AC",138,138,336.4,"ACSR","SINGLE",1,1,"Steel Double Pole",33,0,0,0,1492139,1492139,"application/vnd.ms-excel" 2003,16534,"Sacramento Municipal Util Dist",1,"Natomas","Elverta",100,4.3,"OH","AC",230,230,954,"Aluminum","Single",1,1,"Steel Tower",316,0,0,0,0,0,"application/vnd.ms-excel" 2003,17543,"South Carolina Pub Serv Auth",1,"Rainey - Anderson (Duke) #1","Rainey - Anderson (Duke) #1",100,9.51,"OH","AC",230,230,1272,"ACSR","Double",2,2,"Steel / Tower",956,840152,1230361,1207282,22364,3300159,"application/vnd.ms-excel" 2003,17543,"South Carolina Pub Serv Auth",2,"Rainey - Anderson (Duke) #2","Rainey - Anderson (Duke) #2",100,9.51,"OH","AC",230,230,1272,"ACSR","Double",2,2,"Steel / Tower",956,840152,1230361,1207282,22364,3300159,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",1,"West Ringgold","Center Point",100,7.94,"OH","AC",115,230,954,"ASCR","Single",1,2,"Steel Tower",,2086252,5658529,1502763,3053959,12301503,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",2,"NE Johnson City--Erwin 161kV T","Jonesborough 161 kV SS",100,0.28,"OH","AC",161,161,954,"ASCR","Single",1,1,"Steel Tower",,11050,191917,894933,714987,1812887,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",3,"Elizabethton","Pandara-Shouns",100,15.12,"OH","AC",161,161,636,"ASCR","Single",1,1,"Steel Tower",,282232,1797686,537733,2057572,4675223,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",4,"Sullivan","Blountville",100,0.63,"OH","AC",161,161,1590,"ASCR","Single",2,2,"Steel Tower",,547521,1134556,788061,1224067,3694205,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",5,"Pin Hook","Structure E 104A (NES)",100,1.74,"OH","DC",161,161,2034.5,"ASCR","Single",1,2,"Steel Tower",,179775,881877,641976,270782,1974410,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",6,"Dug Gap 115 kV SS","Center Point 230 kV SS",100,4.49,"OH","AC",115,230,954,"ASCR","Single",2,2,"Steel Tower",,3939251,3451555,545558,1026021,8962385,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",7,"Chickamauga-Ridgedale","Hawthorne 161 kV SS",100,2.82,"OH","AC",161,161,1590,"ASCR","Single",2,2,"Steel Tower",,87206,533582,342640,584799,1548227,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",8,"Ft. Loudoun-Elza 161 kV TL","Spallation Neutron Source 161",100,3.92,"OH","AC",161,161,954,"ASCR","Single",1,1,"Steel Tower",,2972,639541,373150,469765,1485428,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",9,"Leake","Sebastapol SW STA 161 kV",100,0.77,"OH","AC",161,161,636,"ASCR","Single",2,2,"Steel Tower",,36158,236368,103374,167311,543211,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",10,"Sebasatpol 161 kV Switching St","Five Point 161 kV Substation",100,0.13,"OH","AC",161,230,954,"ASCR","Single",1,1,"Steel Tower",,917304,1772761,931352,1477668,5099085,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",11,"Structure 170A","Structure 174",100,0.73,"OH","AC",161,161,636,"ASCR","Single",1,1,"Steel Tower",,0,445863,79638,194574,720075,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",12,"Ramer-Hickory Valley 161 kV TL","Middleton 46 kV SS",100,6.81,"OH","AC",161,161,954,"ASCR","Single",1,1,"Steel Tower",,566805,1162854,447607,787813,2965079,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",13,"Lowndes-Miller","Valley View",100,0.46,"OH","AC",500,500,954,"ASCR","Triple",1,2,"Steel Tower",,0,688737,255237,341129,1285103,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",14,"Sweetwater 161 kV SS","Madisonville 161 kV SS",100,8.95,"OH","AC",161,161,954,"ASCR","Single",1,1,"Steel Tower",,1066219,1474937,466681,797814,3805651,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",15,"East Point 500 kV SS","Hanceville 161 kV TL",100,11.25,"OH","AC",161,161,1351.5,"ASCR","Single",1,2,"Steel Tower",,1416513,1442382,606534,1427424,4892853,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",16,"W Cookeville-Crossville 161 kV","W. Crossville SS",100,4.37,"OH","AC",161,161,954,"ASCR","Single",1,2,"Steel Tower",,267463,1112667,651963,964407,2996500,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",17,"East Shelbyville-Unionville","Deason 161 kV SS",100,5.09,"OH","AC",161,161,636,"ASCR","Single",1,1,"Steel Tower",,1071199,931797,430714,320721,2754431,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",18,"Kentucky Hydro","Barkley Hydro",100,2,"OH","AC",161,161,2034.5,"ACSR","Single",1,1,"Steel Tower",,2845,406947,90111,155401,655304,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",19,"MEC Sw Station","Trinity Substation",100,2.9,"OH","AC",161,161,954,"ACSS","Single",2,2,"Steel Tower",,0,604526,474640,608702,1687868,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",20,"Hickory Valley Selmer 161 kV T","North Selmer 161 kV SS",100,4.88,"OH","AC",161,161,636,"ASCR","Single",1,1,"Steel Tower",,357578,632244,368993,899046,2257861,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",21,"Trinity","Morgan Energy Center",100,2.98,"OH","AC",161,161,1590,"ASCR","Single",2,2,"Steel Tower",,7155,647789,386671,513831,1555446,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",22,"MEC","Finley",100,0.61,"OH","AC",161,161,954,"ASCR","Single",1,2,"Steel Tower",,9879,303540,156165,181613,651197,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",23,"Pickwick-South Jackson","Magic Valley",100,1.38,"OH","AC",161,161,954,"ASCR","Single",1,1,"Steel Pole",,78377,284367,113237,237716,713697,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",24,"Wolf Creek-Choctaw 500 kV TL","Reliant French Camp Gener Plt",100,0.11,"OH","AC",500,500,954,"ASCR","Triple",1,2,"Steel Tower",,0,863770,411493,891161,2166424,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",25,"Widows Creek Ft. Payne 161 kV","Flat Rock 161 kV SS",100,2.05,"OH","AC",161,161,397.5,"ASCR","Single",1,1,"Steel Tower",,130460,443384,182965,410228,1167037,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",26,"Volunteer-Cherokee HP 161 kV T","Oakland 161 kV SS",100,0.5,"OH","AC",161,161,1351,"ASCR","Single",1,2,"Steel Tower",,0,159020,71787,133784,364591,"application/vnd.ms-excel" 2003,18642,"Tennessee Valley Authority",27,"Cordell-Hull-Carthage 161 kV","South Carthage 161 kV SS",100,1.68,"OH","AC",161,161,636,"ASCR","Single",1,2,"Steel Tower",,0,209664,102390,256537,568591,"application/vnd.ms-excel" 2003,20447,"Western Farmers Elec Coop Inc",1,"Arco","Sprectrum",100,5.89,"OH","AC",138,138,336.4,"ACSR","Single",1,1,"Wood Pole",91,37547.56,399750.8,416067.16,0,853365.52,"application/vnd.ms-excel" 2003,20447,"Western Farmers Elec Coop Inc",2,"Hazel Dell Jct","Hazel Dell",100,3.12,"OH","AC",138,138,795,"ACSR","Single",1,1,"Wood Pole",158,72967.09,417464.37,285659.16,0,776090.62,"application/vnd.ms-excel" 2003,20447,"Western Farmers Elec Coop Inc",3,"Red River","Tenaska Kiowa Sw",100,75.75,"OH","AC",345,345,795,"ACSR","Single",1,1,"Combination Pole",158,0,0,0,47569327.23,47569327.23,"application/vnd.ms-excel" 2003,20447,"Western Farmers Elec Coop Inc",4,"Washita Sw","Blue Canyon",100,23.96,"OH","AC",138,138,1590,"ACSR","Single",1,1,"Wood Pole",239,0,0,0,5092171.22,5092171.22,"application/vnd.ms-excel" 2003,20447,"Western Farmers Elec Coop Inc",5,"Limestone Jct","Limestone",100,0.5,"OH","AC",138,138,336.4,"ACSR","Single",1,1,"Wood Pole",91,25673.08,159253.08,77468.07,0,262394.23,"application/vnd.ms-excel" 2003,20447,"Western Farmers Elec Coop Inc",6,"OGE Sunset Jct","Sunset Corner",100,0.15,"OH","AC",161,161,336.4,"ACSR","Singel",1,1,"Wood Pole",91,0,29315.87,35224.01,0,64539.88,"application/vnd.ms-excel" 2003,27000,"Western Area Power Admin",1,"Shiprock","Four Corners",100,8.2,"OH","AC",345,345,,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",2,"Coolidge","Sundance 1 and 2",100,9.8,"OH","AC",230,230,954,"ASCR",,2,2,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",3,"Structure 96/4","O/Banion 1",100,38,"OH","AC",230,230,,"ASCR",,2,2,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",4,"Mead","Market Place",100,12.9,"OH","AC",525,525,,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",5,"Bears Ears","Craig",100,1,"OH","AC",345,345,,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",6,"Glen Canyon Pumping Plant","Glen Canyon SW Yard",100,1,"OH","AC",345,345,,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",7,"Baker","Bowman",22.96,53.96,"OH","AC",230,230,954,"ASCR",,1,1,"Wood H",,0,0,0,0,0 2003,27000,"Western Area Power Admin",8,"Basin Tap #2","Washburn",100,2.23,"OH","AC",230,230,795,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",9,"Craig","Rifle",100,96,"OH","AC",230,230,1272,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",10,"Garrison","Basin Tap #1",100,20.97,"OH","AC",230,230,795,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",11,"Everta","Roseville",100,13.3,"OH","AC",230,230,,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",12,"Griffith","McConnico",100,8,"OH","AC",230,230,1272,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",13,"McConnico","Peacock",100,29.4,"OH","AC",230,230,795,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",14,"Liberty","Buckeye",100,6.7,"OH","AC",230,230,1272,"ASCR",,2,2,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",15,"Liberty","Parker",100,118.7,"OH","AC",230,230,1272,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",16,"Liberty","Estrella",100,10.8,"OH","AC",230,230,954,"ASCR",,2,2,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",17,"Liberty","Lone Batte",100,38.2,"OH","AC",230,230,954,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",18,"Lone Butte","Sundance",100,38.4,"OH","AC",230,230,954,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",19,"New Waddell","West Wing",100,10.1,"OH","AC",230,230,954,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",20,"South Point","Topock #1",100,6.46,"OH","AC",230,230,1590,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0 2003,27000,"Western Area Power Admin",21,"South Point","Topock #2",100,6.34,"OH","AC",230,230,1590,"ASCR",,1,1,"Steel Lattice",,0,0,0,0,0