1

Direct versus Facility Centric Load Control for Automated Demand Response  

SciTech Connect (OSTI)

Direct load control (DLC) refers to the scenario where third party entities outside the home or facility are responsible for deciding how and when specific customer loads will be controlled in response to Demand Response (DR) events on the electric grid. Examples of third parties responsible for performing DLC may be Utilities, Independent System Operators (ISO), Aggregators, or third party control companies. DLC can be contrasted with facility centric load control (FCLC) where the decisions for how loads are controlled are made entirely within the facility or enterprise control systems. In FCLC the facility owner has more freedom of choice in how to respond to DR events on the grid. Both approaches are in use today in automation of DR and both will continue to be used in future market segments including industrial, commercial and residential facilities. This paper will present a framework which can be used to differentiate between DLC and FCLC based upon where decisions are made on how specific loads are controlled in response to DR events. This differentiation is then used to compare and contrast the differences between DLC and FCLC to identify the impact each has on:(1)Utility/ISO and third party systems for managing demand response, (2)Facility systems for implementing load control, (3)Communications networks for interacting with the facility and (4)Facility operators and managers. Finally a survey of some of the existing DR related specifications and communications standards is given and their applicability to DLC or FCLC. In general FCLC adds more cost and responsibilities to the facilities whereas DLC represents higher costs and complexity for the Utility/ISO. This difference is primarily due to where the DR Logic is implemented and the consequences that creates. DLC may be more certain than FCLC because it is more predictable - however as more loads have the capability to respond to DR signals, people may prefer to have their own control of end-use loads and FCLC systems. Research is needed to understand the predictability of FCLC which is related to the perceived value of the DR from the facility manager or home owner's perspective.

Koch, Ed; Piette, Mary Ann

2009-11-06T23:59:59.000Z

2

Residential Air Conditioner Direct Load Control "Energy Partners Program"  

E-Print Network [OSTI]

RESIDENTIAL AIR CONDITIONER DIRECT LOAD CONTROL "ENERGY PARTNERS PROGRAMn John D. Cook Supervisor Houston ABSTRACT Demand side management programs like Energy Partners can provide an effective peak reducing capability which within a.... In this partnership the customer allows HLfP to install a I switch on his/her air conditioner or heat pump and i periodically cycle the unit off during the hottest summer 1 days. In return the customer benefits by receiving an incentive payment, as well...

Cook, J. D.

1994-01-01T23:59:59.000Z

3

Transferability of results from direct load-control (DLC) experiments. Final report  

SciTech Connect (OSTI)

The ability to use test data from another utility to estimate whether a proposed direct load-control program would be cost-effective could save a utility millions of dollars in experimentation costs. Though more work is necessary, this model represents a beginning for the reliable transfer of aggregate site-level data. A computer disk, ''Direct Load Control Impact Assessment Model,'' is included.

Babcock, W.H.; Eckel, J.W.

1986-05-01T23:59:59.000Z

4

Direct versus Facility Centric Load Control for Automated Demand Response  

E-Print Network [OSTI]

Keywords: Demand response, automation, commercial buildings,Demand Response and Energy Efficiency in Commercial Buildings,Building Control Strategies and Techniques for Demand Response.

Piette, Mary Ann

2010-01-01T23:59:59.000Z

5

Deemed Savings Estimates for Legacy Air Conditioning and WaterHeating Direct Load Control Programs in PJM Region  

SciTech Connect (OSTI)

During 2005 and 2006, the PJM Interconnection (PJM) Load Analysis Subcommittee (LAS) examined ways to reduce the costs and improve the effectiveness of its existing measurement and verification (M&V) protocols for Direct Load Control (DLC) programs. The current M&V protocol requires that a PURPA-compliant Load Research study be conducted every five years for each Load-Serving Entity (LSE). The current M&V protocol is expensive to implement and administer particularly for mature load control programs, some of which are marginally cost-effective. There was growing evidence that some LSEs were mothballing or dropping their DLC programs in lieu of incurring the expense associated with the M&V. This project had several objectives: (1) examine the potential for developing deemed savings estimates acceptable to PJM for legacy air conditioning and water heating DLC programs, and (2) explore the development of a collaborative, regional, consensus-based approach for conducting monitoring and verification of load reductions for emerging load management technologies for customers that do not have interval metering capability.

Goldman, Charles

2007-03-01T23:59:59.000Z

6

MODELING AND CONTROL OF THERMOSTATICALLY CONTROLLED LOADS  

E-Print Network [OSTI]

controlled loads (TCLs) has demonstrated that such load following is feasible, but analyt- ical models) is well matched to the role of load following. Re- search into the behavior of TCLs began with the work was then employed in a minimum variance control law to demonstrate the load following capability of a population

Hiskens, Ian A.

7

Building load control and optimization  

E-Print Network [OSTI]

Researchers and practitioners have proposed a variety of solutions to reduce electricity consumption and curtail peak demand. This research focuses on load control by improving the operations in existing building HVAC ...

Xing, Hai-Yun Helen, 1976-

2004-01-01T23:59:59.000Z

8

Modeling and control of thermostatically controlled loads  

SciTech Connect (OSTI)

As the penetration of intermittent energy sources grows substantially, loads will be required to play an increasingly important role in compensating the fast time-scale fluctuations in generated power. Recent numerical modeling of thermostatically controlled loads (TCLs) has demonstrated that such load following is feasible, but analytical models that satisfactorily quantify the aggregate power consumption of a group of TCLs are desired to enable controller design. We develop such a model for the aggregate power response of a homogeneous population of TCLs to uniform variation of all TCL setpoints. A linearized model of the response is derived, and a linear quadratic regulator (LQR) has been designed. Using the TCL setpoint as the control input, the LQR enables aggregate power to track reference signals that exhibit step, ramp and sinusoidal variations. Although much of the work assumes a homogeneous population of TCLs with deterministic dynamics, we also propose a method for probing the dynamics of systems where load characteristics are not well known.

Backhaus, Scott N [Los Alamos National Laboratory; Sinitsyn, Nikolai [Los Alamos National Laboratory; Kundu, S. [UNIV OF MICHIGAN; Hiskens, I. [UNIV OF MICHIGAN

2011-01-04T23:59:59.000Z

9

From Packet to Power Switching: Digital Direct Load Scheduling  

E-Print Network [OSTI]

At present, the power grid has tight control over its dispatchable generation capacity but a very coarse control on the demand. Energy consumers are shielded from making price-aware decisions, which degrades the efficiency of the market. This state of affairs tends to favor fossil fuel generation over renewable sources. Because of the technological difficulties of storing electric energy, the quest for mechanisms that would make the demand for electricity controllable on a day-to-day basis is gaining prominence. The goal of this paper is to provide one such mechanisms, which we call Digital Direct Load Scheduling (DDLS). DDLS is a direct load control mechanism in which we unbundle individual requests for energy and digitize them so that they can be automatically scheduled in a cellular architecture. Specifically, rather than storing energy or interrupting the job of appliances, we choose to hold requests for energy in queues and optimize the service time of individual appliances belonging to a broad class whi...

Alizadeh, Mahnoosh; Thomas, Robert J

2012-01-01T23:59:59.000Z

10

Load-follow control simulation with optimization  

SciTech Connect (OSTI)

For the simulation of load-follow control operation of pressurized water reactors (PWRs), the system model needs to describe both primary and secondary system behaviors, because the load-change signal in the secondary system delivers a change in the primary system through the thermal-hydraulic interactions in the steam generator. In this study, the characteristics of load-follow control for a PWR were investigated using a one-dimensional core model combined with a simplified nuclear steam supply system model using optimization. The overall system model includes one-dimensional core neutronics with all the space-dependent feedback effects, Xe-I dynamics, core thermal balances, primary loop thermal balances, and steam generator dynamic responses to turbine load changes. The final system equations were manipulated for the lumped parameter representations by using the model expansion technique for the core model.

Yim, Man-Sung; Christenson, J.M.

1989-01-01T23:59:59.000Z

11

UTILITY-SCALE SOLAR LOAD CONTROL Richard Perez, ASRC  

E-Print Network [OSTI]

UPEX-02 UTILITY-SCALE SOLAR LOAD CONTROL Richard Perez, ASRC Christy Herig, NREL Ruth Mac Dougall output signals. Utility-scale SLC: when considering an entire utility or a distribution system be impractical to implement. There exists, however, an effective utility- scale SLC implementation via direct

Perez, Richard R.

12

PO. 254 Control of Power Train Loads  

E-Print Network [OSTI]

Abstract summary Variable loads along the power train are the primary cause attributed to the failure of gears, bearings, and other mechanical components. The concept of anticipatory control applied to a wind power train is presented. This new approach to power train load management is based on the data reflecting the current status of the power train. The model driving the optimization of the power train loads considers four different objectives, including minimization of the torque variability and power maximization. A software tool for power train load management is presented. This new approach to power train load control is based on the data reflecting the current status of the power train. Such data is collected by a typical SCADA system. The model driving the optimization of the power train loads considers four different objectives, including minimization of the torque variability and power maximization. Details of the model that is applicable to different turbines are presented Objectives Goal: Transform a wind a farm into a wind power plant Example objectives: ? Minimization of the torque ramp rate ? Maximization of the power produced ? Maximization of the power quality Modify the shape of the power curve Methods Data mining/Knowledge discovery

Andrew Kusiak

13

Incremental cooling load determination for passive direct gain heating systems  

SciTech Connect (OSTI)

This paper examines the applicability of the National Association of Home Builders (NAHB) full load compressor hour method for predicting the cooling load increase in a residence, attributable to direct gain passive heating systems. The NAHB method predictions are compared with the results of 200 hour-by-hour simulations using BLAST and the two methods show reasonable agreement. The degree of agreement and the limitations of the NAHB method are discussed.

Sullivan, P.W.; Mahone, D.; Fuller, W.; Gruber, J.; Kammerud, R.; Place, W.; Andersson, B.

1981-05-01T23:59:59.000Z

14

Active load control techniques for wind turbines.  

SciTech Connect (OSTI)

This report provides an overview on the current state of wind turbine control and introduces a number of active techniques that could be potentially used for control of wind turbine blades. The focus is on research regarding active flow control (AFC) as it applies to wind turbine performance and loads. The techniques and concepts described here are often described as 'smart structures' or 'smart rotor control'. This field is rapidly growing and there are numerous concepts currently being investigated around the world; some concepts already are focused on the wind energy industry and others are intended for use in other fields, but have the potential for wind turbine control. An AFC system can be broken into three categories: controls and sensors, actuators and devices, and the flow phenomena. This report focuses on the research involved with the actuators and devices and the generated flow phenomena caused by each device.

van Dam, C.P. (University of California, Davis, CA); Berg, Dale E.; Johnson, Scott J. (University of California, Davis, CA)

2008-07-01T23:59:59.000Z

15

Generalized solar load ratio correlation for direct gain buildings  

SciTech Connect (OSTI)

A generalized solar load ratio correlation has been developed for direct gain buildings by generating relationships between the correlation parameters and two fundamental design parameters. The first design parameter is the steady state conductance of the solar aperture, U/sub c/. The second is the effective heat capacity of the solar zone, EHC.

Wray, W.O.; Best, E.D.

1986-01-01T23:59:59.000Z

16

Coupling Wind Generation with Controllable Load and Storage  

E-Print Network [OSTI]

Coupling Wind Generation with Controllable Load and Storage: A Time-Series Application of the Super Electric Energy System #12;Coupling Wind Generation with Controllable Load and Storage: A Time Wind Generation with Controllable Load and Storage: A Time-Series Application of the SuperOPF." (PSERC

17

Parasitic load control system for exhaust temperature control  

DOE Patents [OSTI]

A parasitic load control system is provided. The system may include an exhaust producing engine and a fuel pumping mechanism configured to pressurize fuel in a pressure chamber. The system may also include an injection valve configured to cause fuel pressure to build within the pressure chamber when in a first position and allow injection of fuel from the pressure chamber into one or more combustion chambers of the engine when in a second position. The system may further include a controller configured to independently regulate the pressure in the pressure chamber and the injection of fuel into the one or more combustion chambers, to increase a load on the fuel pumping mechanism, increasing parasitic load on the engine, thereby increasing a temperature of the exhaust produced by the engine.

Strauser, Aaron D. (Washington, IL); Coleman, Gerald N. (Peterborough, GB); Coldren, Dana R. (Fairbury, IL)

2009-04-28T23:59:59.000Z

18

Frequency Control Of Micro Hydro Power Plant Using Electronic Load Controller  

E-Print Network [OSTI]

Water turbines, like petrol or diesel engines, will vary in speed as load is applied or relieved. Although not such a great problem with machinery which uses direct shaft power, this speed variation will seriously affect both frequency and voltage output from a generator. Traditionally, complex hydraulic or mechanical speed governors altered flow as the load varied, but more recently an electronic load controller (ELC) has been developed which has increased the simplicity and reliability of modern micro-hydro sets. An ELC is a solid-state electronic device designed to regulate output power of a micro-hydropower system and maintaining a near-constant load on the turbine generates stable voltage and frequency. In this paper an ELC constantly senses and regulates the generated frequency. The frequency is directly proportional to the speed of the turbine.

unknown authors

19

Speed And Power Control Of An Engine By Modulation Of The Load Torque  

DOE Patents [OSTI]

A system and method of speed and power control for an engine in which speed and power of the engine is controlled by modulation of the load torque. The load torque is manipulated in order to cause engine speed, and hence power to be changed. To accomplish such control, the load torque undergoes a temporary excursion in the opposite direction of the desired speed and power change. The engine and the driven equipment will accelerate or decelerate accordingly as the load torque is decreased or increased, relative to the essentially fixed or constant engine torque. As the engine accelerates or decelerates, its power increases or decreases in proportion.

Ziph, Benjamin (Ann Arbor, MI); Strodtman, Scott (Ypsilanti, MI); Rose, Thomas K (Chelsea, MI)

1999-01-26T23:59:59.000Z

20

Combining daylighting, personal controls, and load shedding offers  

E-Print Network [OSTI]

Combining daylighting, personal controls, and load shedding offers enormous potential for reducing lighting system to respond to available daylight and demand response control · Allows building occupants--Consider the improved cost-effectiveness of wireless dimming to promote daylighting controls and load- shedding

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Load controller and method to enhance effective capacity of a photovoltaic power supply using a dynamically determined expected peak loading  

DOE Patents [OSTI]

A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply.

Perez, Richard

2005-05-03T23:59:59.000Z

22

Colloidal Micromotors: Controlled Directed Motion  

E-Print Network [OSTI]

Here we demonstrate a synthetic micro-engine, based on long-range controlled movement of colloidal particles, which is induced by a local catalytic reaction. The directed motion at long timescales was achieved by placing specially designed magnetic capped colloids in a hydrogen peroxide solution at weak magnetic fields. The control of the motion of the particles was provided by changes of the concentration of the solution and by varying the strength of the applied magnetic field. Such synthetic objects can then be used not only to understand the fundamental driving processes but also be employed as small motors in biological environments, for example, for the transportation of molecules in a controllable way.

Baraban, Larysa; Makarov, Denys; Leiderer, Paul; Erbe, Artur

2008-01-01T23:59:59.000Z

23

Colloidal Micromotors: Controlled Directed Motion  

E-Print Network [OSTI]

Here we demonstrate a synthetic micro-engine, based on long-range controlled movement of colloidal particles, which is induced by a local catalytic reaction. The directed motion at long timescales was achieved by placing specially designed magnetic capped colloids in a hydrogen peroxide solution at weak magnetic fields. The control of the motion of the particles was provided by changes of the concentration of the solution and by varying the strength of the applied magnetic field. Such synthetic objects can then be used not only to understand the fundamental driving processes but also be employed as small motors in biological environments, for example, for the transportation of molecules in a controllable way.

Larysa Baraban; Christian Kreidler; Denys Makarov; Paul Leiderer; Artur Erbe

2008-07-10T23:59:59.000Z

24

THERMAL LOADING OF A DIRECT DRIVE TARGET IN  

E-Print Network [OSTI]

optics. A background gas, such as Xe, could reduce the damage on the wall from ion and heat loading fusion micro explosion (~ 10 Hz), ions and heat loads threaten to damage the reactor wall and driver. · The thermal loading of a target (radiation from the chamber wall and convection from the protective gas) may

Raffray, A. René

25

Energy Storage for Use in Load Frequency Control  

E-Print Network [OSTI]

Certain energy storage technologies are well-suited to the high-frequency, high-cycling operation which is required in provision of load frequency control (LFC). To limit the total stored energy capacity required while ...

Leitermann, Olivia

26

Automatic load follow control system for PWR plants  

SciTech Connect (OSTI)

In Japan, load follow operation (daily load follow, automatic frequency control (AFC) operation, and governor free (GF) operation) of nuclear plants will be required in the near future to control grid frequency, as the ratio of nuclear plant electrical production to total grid production will increase. The AFC operation regulated power by demand from the central load dispatcher to control mainly the fringe component of the grid frequency fluctuation, and GF operation regulates power by turbine revolution or grid frequency to control mainly the cyclic component of grid frequency fluctuation. This paper deals with the automatic power distribution control system, which is important to load follow operation and possibly will be applied to pressurized water reactor (PWR) nuclear plants. The reactor control systems noted below are conventional design with some improvements for AFC/GF operation, so that the reactor operates the turbine as before: (1) rod control system (reactor power control); (2) pressurizer pressure control system; (3) pressurizer level control system; and (4) steam generator level control system.

Nakakura, H.; Ishiguro, A.

1987-01-01T23:59:59.000Z

27

Load controller and method to enhance effective capacity of a photovotaic power supply using a dynamically determined expected peak loading  

DOE Patents [OSTI]

A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The expected peak loading of the variable load can be dynamically determined within a defined time interval with reference to variations in the variable load.

Perez, Richard (Delmar, NY)

2003-04-01T23:59:59.000Z

28

Optimal control theory for xenon spatial oscillations in load follow of a nuclear reactor  

SciTech Connect (OSTI)

A simple core control model has been developed for the control of xenon spatial oscillations in load-following operations of a current design commercial nuclear pressurized water reactor. The model has been formulated as a linear - quadratic - tracking problem in the context of moderm optimal control theory and the resulting two-point boundary value problem (TPBVP) has been solved directly by the techniques of initial value methods.

Cho, N.Z.

1980-01-01T23:59:59.000Z

29

Load frequency control of interconnected power systems with system constraints  

E-Print Network [OSTI]

Responses D. Generating Unit Characteristics E. The State Variable Representation of the Dynamic F. LFC System Data . 1. Power System Data 2. Controller Gains 3. The Reheat-turbine Prime-Mover Data Model . 6 7 8 10 11 12 15 15 18 23 23 25... 56 25 LFC system response with VSS control. Area 1 fails to respond for a load change of APnr ? 0, 01 p. u. 57 26 LFC system response with conventional controL Area 1 fails to respond for the same load disturbance as in Fig. 26. . . 58 27...

Choudhury, Md Ershadul H

1993-01-01T23:59:59.000Z

30

Reducing Power Load Fluctuations on Ships Using Power Redistribution Control  

E-Print Network [OSTI]

controller is demonstrated through simulation studies on a supply vessel power plant, using the SIMULINK plant with electric propulsion, the power generation will con- sist of multiple engines, whereReducing Power Load Fluctuations on Ships Using Power Redistribution Control Damir Radan,1 Asgeir J

Johansen, Tor Arne

31

Pilot plant used to develop load and pressure controller  

SciTech Connect (OSTI)

Viewed from the perspective of the power-generation mixture in Japan, nuclear power plants will continue to be operated to meet the base load. Meanwhile, integrated coal gasification combined cycle (IGCC) power plants will be required to serve as thermal power plants to cover the middle load, as is the case with conventional thermal power plants. In terms of operational performance, therefore, IGCC power plants will need to have a capability of following a wide range of load demand at high speed. For this purpose, a load and pressure controller was developed and tested during the operational research on a 200 tons/day entrained flow IGCC pilot plant at the Nakoso Power Station by the Engineering Research Association for IGCC Power Systems (IGC Association). This article reports on the development of the load and pressure controller and the results of the control test carried out to check the load follow capability of the pilot plant, while touching upon the simulation study also being conducted.

Nagata, Kazue; Yamada, Toshihiro; Hiza, Tomoyuki

1997-02-01T23:59:59.000Z

32

Turbine blade damping device with controlled loading  

SciTech Connect (OSTI)

A damping structure for a turbomachine rotor. The damping structure including an elongated snubber element including a first snubber end rigidly attached to a first blade and extending toward an adjacent second blade, and an opposite second snubber end positioned adjacent to a cooperating surface associated with the second blade. The snubber element has a centerline extending radially inwardly in a direction from the first blade toward the second blade along at least a portion of the snubber element between the first and second snubber ends. Rotational movement of the rotor effects relative movement between the second snubber end and the cooperating surface to position the second snubber end in frictional engagement with the cooperating surface with a predetermined damping force determined by a centrifugal force on the snubber element.

Marra, John J

2013-09-24T23:59:59.000Z

33

Designing and Testing Controls to Mitigate Tower Dynamic Loads in the Controls Advanced Research Turbine: Preprint  

SciTech Connect (OSTI)

This report describes NREL's efforts to design, implement, and test advanced controls for maximizing energy extraction and reducing structural dynamic loads in wind turbines.

Wright, A. D.; Fingersh, L. J.; Stol, K. A.

2007-01-01T23:59:59.000Z

34

Selecting a Control Strategy for Plug and Process Loads  

SciTech Connect (OSTI)

Plug and Process Loads (PPLs) are building loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and typically do not provide comfort to the building occupants. PPLs in commercial buildings account for almost 5% of U.S. primary energy consumption. On an individual building level, they account for approximately 25% of the total electrical load in a minimally code-compliant commercial building, and can exceed 50% in an ultra-high efficiency building such as the National Renewable Energy Laboratory's (NREL) Research Support Facility (RSF) (Lobato et al. 2010). Minimizing these loads is a primary challenge in the design and operation of an energy-efficient building. A complex array of technologies that measure and manage PPLs has emerged in the marketplace. Some fall short of manufacturer performance claims, however. NREL has been actively engaged in developing an evaluation and selection process for PPLs control, and is using this process to evaluate a range of technologies for active PPLs management that will cap RSF plug loads. Using a control strategy to match plug load use to users' required job functions is a huge untapped potential for energy savings.

Lobato, C.; Sheppy, M.; Brackney, L.; Pless, S.; Torcellini, P.

2012-09-01T23:59:59.000Z

35

Engine combustion control at low loads via fuel reactivity stratification  

DOE Patents [OSTI]

A compression ignition (diesel) engine uses two or more fuel charges during a combustion cycle, with the fuel charges having two or more reactivities (e.g., different cetane numbers), in order to control the timing and duration of combustion. By appropriately choosing the reactivities of the charges, their relative amounts, and their timing, combustion can be tailored to achieve optimal power output (and thus fuel efficiency), at controlled temperatures (and thus controlled NOx), and with controlled equivalence ratios (and thus controlled soot). At low load and no load (idling) conditions, the aforementioned results are attained by restricting airflow to the combustion chamber during the intake stroke (as by throttling the incoming air at or prior to the combustion chamber's intake port) so that the cylinder air pressure is below ambient pressure at the start of the compression stroke.

Reitz, Rolf Deneys; Hanson, Reed M; Splitter, Derek A; Kokjohn, Sage L

2014-10-07T23:59:59.000Z

36

A Generalized Battery Model of a Collection of Thermostatically Controlled Loads for Providing Ancillary Service  

E-Print Network [OSTI]

. Residential Thermostatically Controlled Loads (TCLs) such as air conditioner, heat pump, water heater, and re

Sanandaji, Borhan M.

37

{Control of Residential Load Management Networks Using Real Time Pricing  

E-Print Network [OSTI]

loads to deliver load following and regulation, withproducts like load following and spinning reserve.following of constant power references. Chapter 7 Implications of Load

Burke, William Jerome

2010-01-01T23:59:59.000Z

38

Load-follow operation with the MSHIM control system  

SciTech Connect (OSTI)

As part of Westinghouse Electric Corporation's ongoing efforts to improve plant daily load-follow capability, a system has been developed that promises a significant enhancement of current load-maneuvering capabilities, while simultaneously reducing the burden on operators and plant systems. This concept, the mechanical shim (MSHIM), control system utilizes two independently operable groups of control banks for essentially simultaneous control of reactivity and axial power distribution. This system has been developed with the goal of supporting either of two operational modes. One mode is designed to maximize spinning reserve (MAXSR) capacity (return to full-power capability). The other mode minimizes boric (MINB) acid changes, hence effluent production, during the power maneuver. The features of the two control modes are summarized.

Morita, T.; Carlsen, B.W.; Kutz, J.P.

1988-01-01T23:59:59.000Z

39

Engineering to Control Noise, Loading, and Optimal Operating Points  

SciTech Connect (OSTI)

Successful engineering of low-energy nuclear systems requires control of noise, loading, and optimum operating point (OOP) manifolds. The latter result from the biphasic system response of low-energy nuclear reaction (LENR)/cold fusion systems, and their ash production rate, to input electrical power. Knowledge of the optimal operating point manifold can improve the reproducibility and efficacy of these systems in several ways. Improved control of noise, loading, and peak production rates is available through the study, and use, of OOP manifolds. Engineering of systems toward the OOP-manifold drive-point peak may, with inclusion of geometric factors, permit more accurate uniform determinations of the calibrated activity of these materials/systems.

Mitchell R. Swartz

2000-11-12T23:59:59.000Z

40

Extension of load follow capability of a PWR reactor by optimal control  

SciTech Connect (OSTI)

The problem of extending that part of the fuel life cycle during which a reactor is capable of sustaining load-follow operation is formulated as an optimal control problem. A two-node model representation of pressurized water reactor dynamics is used, leading to a set of non-linear ordinary differential equations. Differential Dynamic Programming is used to solve directly the resulting nonlinear optimization problem and obtain the trajectories of soluble boron concentration and control rod insertion. Results of computations performed for a reference reactor are presented, showing how the optimal control policy stretches the capability of the reactor to follow an average daily load curve towards the end of the fuel life cycle.

Winokur, M.; Tepper, L.

1984-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Systems and methods for providing power to a load based upon a control strategy  

DOE Patents [OSTI]

Systems and methods are provided for an electrical system. The electrical system includes a load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage from the voltage source through the interface and to provide a voltage and current to the load. Wherein, when the controller is in a constant voltage mode, the controller provides a constant voltage to the load, when the controller is in a constant current mode, the controller provides a constant current to the load, and when the controller is in a constant power mode, the controller provides a constant power to the load.

Perisic, Milun; Kajouke, Lateef A; Ransom, Ray M

2013-12-24T23:59:59.000Z

42

Numerical modeling of effect of polyurea on response of steel plates to impulsive loads in direct pressure-pulse experiments  

E-Print Network [OSTI]

Numerical modeling of effect of polyurea on response of steel plates to impulsive loads in direct is studied, focusing on the effects of the relative position of polyurea with respect to the loading plates subjected to uniform blast loads and compared their predictions with experimental results. Bahei

Nemat-Nasser, Sia

43

Load controller and method to enhance effective capacity of a photovoltaic power supply  

DOE Patents [OSTI]

A load controller and method are provided for maximizing effective capacity of a non-controllable, renewable power supply coupled to a variable electrical load also coupled to a conventional power grid. Effective capacity is enhanced by monitoring power output of the renewable supply and loading, and comparing the loading against the power output and a load adjustment threshold determined from an expected peak loading. A value for a load adjustment parameter is calculated by subtracting the renewable supply output and the load adjustment parameter from the current load. This value is then employed to control the variable load in an amount proportional to the value of the load control parameter when the parameter is within a predefined range. By so controlling the load, the effective capacity of the non-controllable, renewable power supply is increased without any attempt at operational feedback control of the renewable supply. The renewable supply may comprise, for example, a photovoltaic power supply or a wind-based power supply.

Perez, Richard (Delmar, NY)

2000-01-01T23:59:59.000Z

44

Direct versus Facility Centric Load Control for Automated Demand Response  

E-Print Network [OSTI]

applications. Mary Ann Piette is a Staff Scientist atResponse Ed Koch, Akuacom Mary Ann Piette, Lawrence BerkeleyCA 94903 ed@akuacom.com Mary Ann Piette Lawrence Berkeley

Piette, Mary Ann

2010-01-01T23:59:59.000Z

45

Direct versus Facility Centric Load Control for Automated Demand Response  

E-Print Network [OSTI]

Interoperable Automated Demand Response Infrastructure.and Techniques for Demand Response. LBNL Report 59975. Mayand Communications for Demand Response and Energy Efficiency

Piette, Mary Ann

2010-01-01T23:59:59.000Z

46

Controlling entanglement by direct quantum feedback  

E-Print Network [OSTI]

We discuss the generation of entanglement between electronic states of two atoms in a cavity using direct quantum feedback schemes. We compare the effects of different control Hamiltonians and detection processes in the performance of entanglement production and show that the quantum-jump-based feedback proposed by us in Phys. Rev. A {\\bf 76} 010301(R) (2007) can protect highly entangled states against decoherence. We provide analytical results that explain the robustness of jump feedback, and also analyse the perspectives of experimental implementation by scrutinising the effects of imperfections and approximations in our model.

A. R. R. Carvalho; A. J. S. Reid; J. J. Hope

2008-07-07T23:59:59.000Z

47

Development and Validation of Aggregated Models for Thermostatic Controlled Loads with Demand Response  

SciTech Connect (OSTI)

Demand response is playing an increasingly important role in smart grid research and technologies being examined in recently undertaken demonstration projects. The behavior of load as it is affected by various load control strategies is important to understanding the degree to which different classes of end-use load can contribute to demand response programs at various times. This paper focuses on developing aggregated control models for a population of thermostatically controlled loads. The effects of demand response on the load population dynamics are investigated.

Kalsi, Karanjit; Elizondo, Marcelo A.; Fuller, Jason C.; Lu, Shuai; Chassin, David P.

2012-01-04T23:59:59.000Z

48

Aggregate Model for Heterogeneous Thermostatically Controlled Loads with Demand Response  

SciTech Connect (OSTI)

Due to the potentially large number of Distributed Energy Resources (DERs) demand response, distributed generation, distributed storage - that are expected to be deployed, it is impractical to use detailed models of these resources when integrated with the transmission system. Being able to accurately estimate the fast transients caused by demand response is especially important to analyze the stability of the system under different demand response strategies. On the other hand, a less complex model is more amenable to design feedback control strategies for the population of devices to provide ancillary services. The main contribution of this paper is to develop aggregated models for a heterogeneous population of Thermostatic Controlled Loads (TCLs) to accurately capture their collective behavior under demand response and other time varying effects of the system. The aggregated model efficiently includes statistical information of the population and accounts for a second order effect necessary to accurately capture the collective dynamic behavior. The developed aggregated models are validated against simulations of thousands of detailed building models using GridLAB-D (an open source distribution simulation software) under both steady state and severe dynamic conditions caused due to temperature set point changes.

Zhang, Wei; Kalsi, Karanjit; Fuller, Jason C.; Elizondo, Marcelo A.; Chassin, David P.

2012-07-22T23:59:59.000Z

49

Photovoltaic power converter system with a controller configured to actively compensate load harmonics  

DOE Patents [OSTI]

Photovoltaic power converter system including a controller configured to reduce load harmonics is provided. The system comprises a photovoltaic array and an inverter electrically coupled to the array to generate an output current for energizing a load connected to the inverter and to a mains grid supply voltage. The system further comprises a controller including a first circuit coupled to receive a load current to measure a harmonic current in the load current. The controller includes a second circuit to generate a fundamental reference drawn by the load. The controller further includes a third circuit for combining the measured harmonic current and the fundamental reference to generate a command output signal for generating the output current for energizing the load connected to the inverter. The photovoltaic system may be configured to compensate harmonic currents that may be drawn by the load.

de Rooij, Michael Andrew (Clifton Park, NY); Steigerwald, Robert Louis (Burnt Hills, NY); Delgado, Eladio Clemente (Burnt Hills, NY)

2008-12-16T23:59:59.000Z

50

An MILP Formulation for Load-Side Demand Control Zhonghui Luo, Ratnesh Kumar*  

E-Print Network [OSTI]

Demand control systems can be divided functionally into supply-side and load-side control/management systems. Supply-side demand management systems, implemented by the utilities, choose between maintainingAn MILP Formulation for Load-Side Demand Control Zhonghui Luo, Ratnesh Kumar* , Joseph Sottile

Kumar, Ratnesh

51

Load Alleviation through Adaptive Trailing Edge Control Surfaces: ADAPWING Overview  

E-Print Network [OSTI]

to investigate the potential of using adaptive trailing edge geometry on wind turbine blades as load alleviation field experienced by wind turbine blades is turbulent which causes fluctuating loads during nor- mal for the wind turbine industry if the alleviation systems do not add considerable extra cost. Recent work has

52

Aggregated Modeling of Thermostatic Loads in Demand Response: A Systems and Control Perspective  

SciTech Connect (OSTI)

Demand response is playing an increasingly important role in smart grid research and technologies being examined in recently undertaken demonstration projects. The behavior of load as it is affected by various load control strategies is important to understanding the degree to which different classes of end-use load can contribute to demand response programs at various times. This paper focuses on developing aggregated models for a homogeneous population of thermostatically controlled loads. The different types of loads considered in this paper include, but are not limited to, water heaters and HVAC units. The effects of demand response and user over-ride on the load population dynamics are investigated. The controllability of the developed lumped models is validated which forms the basis for designing different control strategies.

Kalsi, Karanjit; Chassin, Forrest S.; Chassin, David P.

2011-12-12T23:59:59.000Z

53

Characterization of Engine Control Authority on HCCI Combustion as the High Load Limit is Approached  

SciTech Connect (OSTI)

While the potential emissions and efficiency benefits of homogeneous charge compression ignition (HCCI) combustion are well known, realizing the potentials on a production intent engine presents numerous challenges. In this study we focus on characterizing the authority of the available engine controls as the high load limit of HCCI combustion is approached. The experimental work is performed on a boosted single-cylinder research engine equipped with direct injection (DI) fueling, cooled external exhaust gas recirculation (EGR), and a hydraulic valve actuation (HVA) valve train to enable the negative valve overlap (NVO) breathing strategy. Valve lift and duration are held constant while phasing is varied in an effort to make the results as relevant as possible to production intent cam-based variable valve actuation (VVA) systems on multi-cylinder engines. Results presented include engine loads from 350 to 650 kPa IMEPnet and manifold pressure from 98 to 190 kPaa at 2000 rpm. It is found that in order to increase engine load to 650 kPa IMEPnet, it is necessary to increase manifold pressure and external EGR while reducing the NVO duration. Both NVO duration and fuel injection timing are effective means of controlling combustion phasing, with NVO duration being a coarse control and fuel injection timing being a fine control. NOX emissions are low throughout the study, with emissions below 0.1 g/kW-h at all boosted HCCI conditions, while good combustion efficiency is maintained (>96.5%). Net indicated thermal efficiency increases with load up to 600 kPa IMEPnet, where a peak efficiency of 41% is achieved. Results of independent parametric investigations are presented on the effect of external EGR, intake effect of manifold pressure, and the effect of NVO duration. It is found that increasing EGR at a constant manifold pressure and increasing manifold pressure at a constant EGR rate both have the effect of retarding combustion phasing. It is also found that combustion phasing becomes increasingly sensitive to NVO duration as engine load increases. Finally, comparisons are made between three commonly used noise metrics (AVL noise meter, ringing intensity (RI), and maximum pressure rise rate (MPRR)). It is found that compared to the AVL noise meter, RI significantly underestimates combustion noise under boosted conditions.

Szybist, James P [ORNL] [ORNL; Edwards, Kevin Dean [ORNL] [ORNL; Foster, Matthew [Delphi] [Delphi; Confer, Keith [Delphi] [Delphi; Moore, Wayne [Delphi] [Delphi

2013-01-01T23:59:59.000Z

54

A Study of the Pre-Programmed Thermostat Timer as a Load Control Device  

E-Print Network [OSTI]

. The purpose of this research was to determine if a pre-programs3 thmstat timing device can operate similarly to a dispatcher controlled load managanent device to rehce peak generation dmds without adversely affecting energy kwh) sales. SCOPE: The scope... of this research is: (1) to detennine if the device can be used as a viable means of load reduction, (2) to determine the parameters for equiprent and programing for more extensive research involving dispatcher control of dis- tribution load, and (3...

Wallace, M. L.; Thedford, M.

1985-01-01T23:59:59.000Z

55

Abstract--This paper formulates and develops a peak demand control tool for electric systems within the framework of direct  

E-Print Network [OSTI]

techniques. Index Terms--Demand Side Management, direct load control, peak demand control, genetic algorithms in order to evaluate the suitability of the decision chosen. The Demand Side Management (DSM) plans attempt for central air conditioning systems in commercial buildings, hence allowing a measured control of peak demand

Catholic University of Chile (Universidad Católica de Chile)

56

Abstract--This paper formulates and develops a peak demand control tool for electric systems within the framework of direct  

E-Print Network [OSTI]

techniques. Index Terms--Demand Side Management, direct load control, peak demand control, genetic algorithms in order to evaluate the suitability of the decision chosen. Demand Side Management (DSM) plans attempt for central air conditioning systems in commercial buildings, hence allowing a measured control of peak demand

Catholic University of Chile (Universidad Católica de Chile)

57

Coordination of Voltage and Frequency Feedback in Load-Frequency Control Capability of Wind Turbine  

E-Print Network [OSTI]

Coordination of Voltage and Frequency Feedback in Load-Frequency Control Capability of Wind Turbine-Frequency Control (LFC) is gradually shifted to Variable Speed Wind Turbines (VSWTs). In order to equip VSWT

Silva, Filipe Faria Da

58

Effects of Biodiesel and Engine Load on Some Emission Characteristics of a Direct Injection Diesel Engine  

E-Print Network [OSTI]

In this research, experiments were conducted on a 4-cylinder direct-injection diesel engine using biodiesel as an alternative fuel and their blends to investigate the emission characteristics of the engine under four engine loads (25%, 40%, 65 % and 80%) at an engine speed of 1800 rev/min. A test was applied in which an engine was fueled with diesel and four different blends of diesel/ biodiesel (B20, B40, B60 and B80) made from waste frying oil and the results were analyzed. The use of biodiesel resulted in lower emissions of hydrocarbon (HC) and CO and increased emissions

Alireza Shirneshan; Morteza Almassi; Barat Ghobadian; Ali Mohammad Borghei; Gholam Hassan Najafi

2012-01-01T23:59:59.000Z

59

Adaptive load control of microgrids with non-dispatchable generation  

E-Print Network [OSTI]

Intelligent appliances have a great potential to provide energy storage and load shedding for power grids. Microgrids are simulated with high levels of wind energy penetration. Frequency-adaptive intelligent appliances are ...

Brokish, Kevin Martin

2009-01-01T23:59:59.000Z

60

Evaluation of fossil plants versus hydro plants for load frequency control  

SciTech Connect (OSTI)

The economics of using hydroplants with Francis turbines or fossil plants for load frequency control are evaluated. Using data from the TVA Gallatin steam plant and the TVA Cherokee, Wilson, and Fontana hydroplants, a cost comparison of different modes of operation for load frequency control was performed considering two plants at a time. The results showed that when the fossil plant was used for load frequency control instead of a hydro plant a lower system generation cost was incurred. Dynamic responses of fossil and hydro units, improved controls for fossil plants, and maneuvering costs of the Gallatin plant are also considered.

Broadwater, R.P.; Johnson, R.L.; Duckett, F.E.; Boston, W.T.

1985-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Systems and methods for providing power to a load based upon a control strategy  

DOE Patents [OSTI]

Systems and methods are provided for an electrical system. The electrical system, for example, includes a first load, an interface configured to receive a voltage from a voltage source, and a controller configured to receive the voltage through the interface and to provide a voltage and current to the first load. The controller may be further configured to, receive information on a second load electrically connected to the voltage source, determine an amount of reactive current to return to the voltage source such that a current drawn by the electrical system and the second load from the voltage source is substantially real, and provide the determined reactive current to the voltage source.

Perisic, Milun; Lawrence, Christopher P; Ransom, Ray M; Kajouke, Lateef A

2014-11-04T23:59:59.000Z

62

Load-following control of an IGCC plant with CO2 capture  

SciTech Connect (OSTI)

In this paper, a decentralized control strategy is considered for load-following control of an integrated gasification combined cycle (IGCC) plant with CO2 capture without flaring the syngas. The control strategy considered is gas turbine (GT) lead with gasifier follow. In this strategy, the GT controls the power load by manipulating its firing rate while the slurry feed flow to the gasifier is manipulated to control the syngas pressure at the GT inlet. However, the syngas pressure control is an integrating process with significant timedelay. In this work, a modified proportional-integral-derivative (PID) control is considered for syngas pressure control given that conventional PID controllers show poor control performance for integrating processes with large time delays. The conventional PID control is augmented with an internal feedback loop. The P-controller used in this internal loop converts the integrating process to an open-loop stable process. The resulting secondorder plus time delay model uses a PID controller where the tuning parameters are found by minimizing the integral time-weighted absolute error (ITAE) for disturbance rejection. A plant model with single integrator and time delay is identified by a P-control method. When a ramp change is introduced in the set-point of the load controller, the performance of both the load and pressure controllers with the modified PID control strategy is found to be superior to that using a traditional PID controller. Key

Bhattacharyya, D.; Turton, R.; Zitney, S.

2011-01-01T23:59:59.000Z

63

LQG control of horizontal wind turbines for blades and tower loads alleviation  

E-Print Network [OSTI]

LQG control of horizontal wind turbines for blades and tower loads alleviation A. Pintea*, N of power produced by two bladed horizontal variable speed wind turbines. The proposed controller ensures oscillations and with the tower bending tendency. Keywords: LQG control, Wind turbines, Multi-objective control

Paris-Sud XI, Université de

64

Session: Loads and control (BT4.1) Track: Technical  

E-Print Network [OSTI]

, which is one of the few fully instrumented towers reaching above the height of the largest wind turbines the same results. The investigations have shown that the response on the wind turbines are deferring up of Kaimal when estimating the coherences for larger scales and thereby the loads on the tower. The paper

65

Advanced Wind Turbine Controls Reduce Loads (Fact Sheet)  

SciTech Connect (OSTI)

NREL's National Wind Technology Center provides the world's only dedicated turbine controls testing platforms.

Not Available

2012-03-01T23:59:59.000Z

66

Optimal Industrial Load Control in Smart Grid: A Case Study for Oil Refineries  

E-Print Network [OSTI]

Optimal Industrial Load Control in Smart Grid: A Case Study for Oil Refineries Armen Gholian, Hamed units finish their operations. Considering an oil refinery industry as an example, we not only identify Terms­Demand response, load management, manufactur- ing industries, oil refineries, optimal scheduling

Mohsenian-Rad, Hamed

67

Fuel Governor Augmented Control of Recompression HCCI Combustion During Large Load Transients  

E-Print Network [OSTI]

Fuel Governor Augmented Control of Recompression HCCI Combustion During Large Load Transients Shyam desired com- bustion phasing for a homogeneous charge compression ignition (HCCI) engine during large load strategy that can track combustion phasing in a recompression homogeneous charge compression ignition (HCCI

Stefanopoulou, Anna

68

Mitigation of Fatigue Loads Using Individual Pitch Control of Wind Turbines Based on FAST  

E-Print Network [OSTI]

Mitigation of Fatigue Loads Using Individual Pitch Control of Wind Turbines Based on FAST Yunqian University, China jiz@seu.edu.cn Abstract-With the increase of wind turbine dimension and capacity, the wind turbine structures are subjected to prominent loads and fatigue which would reduce the lifetime of wind

Chen, Zhe

69

Aggregated Modeling and Control of Air Conditioning Loads for Demand Response  

E-Print Network [OSTI]

1 Aggregated Modeling and Control of Air Conditioning Loads for Demand Response Wei Zhang, Member, IEEE Abstract--Demand response is playing an increasingly impor- tant role in the efficient loads is especially important to evaluate the effec- tiveness of various demand response strategies

Zhang, Wei

70

Real-Time Deferrable Load Control: Handling the Uncertainties of Renewable Generation  

E-Print Network [OSTI]

@caltech.edu Steven H. Low California Inst. of Tech. slow@caltech.edu ABSTRACT Real-time demand response is potential loads, including electric vehicles and smart appliances, will participate in demand response smart grid, deferrable load control, demand response 1. INTRODUCTION Real-time demand response seeks

Low, Steven H.

71

Methods and apparatus for rotor load control in wind turbines  

DOE Patents [OSTI]

A wind turbine having a rotor, at least one rotor blade, and a plurality of generators, of which a first generator is configured to provide power to an electric grid and a second generator is configured to provide power to the wind turbine during times of grid loss. The wind turbine is configured to utilize power provided by the second generator to reduce loads on the wind turbine during times of grid loss.

Moroz, Emilian Mieczyslaw

2006-08-22T23:59:59.000Z

72

NREL Reduces Climate Control Loads in Electric Vehicles (Fact Sheet)  

SciTech Connect (OSTI)

NREL demonstrates that zonal climate control can reduce air conditioning power and improve range while maintaining driver thermal sensation.

Not Available

2014-08-01T23:59:59.000Z

73

Power System Dynamics as Primal-Dual Algorithm for Optimal Load Control  

E-Print Network [OSTI]

in the Proceedings of the 3rd IEEE International Conference on Smart Grid Communica- tions, Tainan City, Taiwan- based load control does not require communication to a centralized grid operator, and is thus suitable for

Low, Steven H.

74

Benefits of Industrial Boiler Control and Economic Load Allocation at AMOCO Chemicals, Decatur, Alabama  

E-Print Network [OSTI]

The objective of this paper is to provide an overview of the economic benefits realized by Amoco's Decatur plant from the utilization of Honeywell's Industrial Boiler Control solution and Turbo Economic Load Allocation packages on an integrated four...

Winter, J.

75

Gain-scheduled controller design for load-following in static space nuclear power systems  

E-Print Network [OSTI]

of variations in the fuel temperature reactivity feedback coeficient on the load-following capabilities of the SNPS. Robustness analysis results of the gain-scheduled compensator demonstrate that the proposed control concept exhibits a significant degree...

Onbasioglu, Fetiye Ozlem

1993-01-01T23:59:59.000Z

76

OPERATOR PERFORMANCE IN LONG DURATION, LOW TASK LOAD CONTROL OPERATIONS  

E-Print Network [OSTI]

and conducted. Overall, 36 participants operated a digital nuclear power plant control workstation simulation In the United States, a major effort is underway to modernize existing nuclear power plants and their control rooms, as well as design new, advanced nuclear power plants. Current control rooms for nuclear power

Cummings, Mary "Missy"

77

Load follow-up control of a pressurized water reactor power plant by using an approximate noninteractive control  

SciTech Connect (OSTI)

The present paper describes an attempt to apply an approximate noninteractive control to the load-following operation of the nuclear steam supply (NSS) system of a pressurized water reactor power plant. A control strategy is proposed for maximizing the unique merit of the noninteractive control in advancing the operational performance of the NSS system. An noninteractive load follow-up control system is designed based on the idea of approximate model-following. The authors make the design method more flexible and widely applicable to more general control problems by introducing some modifications. Digital simulations and graphical studies based on the Bode-diagram demonstrate the effectiveness of the noninteractive load follow-up control as well as the applicability of the proposed design method.

Tsuji, M.; Ogawa, Y.

1986-08-01T23:59:59.000Z

78

Project Controls - DOE Directives, Delegations, and Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

description of project controls and the role the cost estimation package plays. g4301-1chp14.pdf -- PDF Document, 6 KB Writer: John Makepeace Subjects: Administration Management...

79

Demand Response-Enabled Model Predictive HVAC Load Control in Buildings using Real-Time Electricity Pricing.  

E-Print Network [OSTI]

??A practical cost and energy efficient model predictive control (MPC) strategy is proposed for HVAC load control under dynamic real-time electricity pricing. The MPC strategy (more)

Avci, Mesut

2013-01-01T23:59:59.000Z

80

active load control: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

for nuclear power and conducted. Overall, 36 participants operated a digital nuclear power plant control workstation simulation Cummings, Mary "Missy" 47 Real-Time Deferrable...

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Aggregate Flexibility of Thermostatically Controlled Loads He Haoa, Borhan M. Sanandajib, Kameshwar Poollac, and Tyrone L. Vincentd  

E-Print Network [OSTI]

(TCLs) such as air conditioners, heat pumps, water heaters, and refrigera- to&E, aggregate residential air conditioners for peak load shaving and emergency load management [6]. Because services such as frequency regulation or load-following. Residential Thermostatically Controlled Loads

Sanandaji, Borhan M.

82

High load limits of the controlled autoignition engine  

E-Print Network [OSTI]

The controlled autoignition (CAI) engine is an engine concept that features very low soot and NOx emissions while achieving diesel-like efficiency. The CAI combustion process is characterized by a fast, volumetric burn of ...

Wildman, Craig B. E. (Craig Bradley Edward), 1987-

2009-01-01T23:59:59.000Z

83

Fuel Effects on Combustion and Emissions of a Direct-Inection Diesel Engine Operating at Moderate to High Engine Speed and Load  

SciTech Connect (OSTI)

It is advantageous to increase the specific power output of diesel engines and to operate them at higher load for a greater portion of a driving cycle to achieve better thermal efficiency and thus reduce vehicle fuel consumption. Such operation is limited by excessive smoke formation at retarded injection timing and high rates of cylinder pressure rise at more advanced timing. Given this window of operation, it is desired to understand the influence of fuel properties such that optimum combustion performance and emissions can be retained over the range of fuels commonly available in the marketplace. It has been shown in previous studies that varying cetane number (CN) of diesel fuel has little effect on ignition delay at high engine load due to the domination of high cylinder temperature on ignition kinetics. The work here experimentally confirms that finding but also shows that emissions and combustion performance vary according to fuel reactivity. Data are examined from a direct-injection single cylinder research engine for eight common diesel fuels including soy-based biodiesel blends at two high load operating points with no exhaust gas recirculation (EGR) and at a moderate load with four levels of EGR. It is shown in the work that at high engine load where combustion is controlled by mixing processes, CN and other fuel properties have little effect on engine performance, although lower CN fuels produce a small increase in noise, smoke and CO emissions. Biodiesel blends increase NOX emissions and decreases CO and smoke emissions at high load, but otherwise have little effect on performance. At moderate load, higher CN fuels are more tolerant to EGR due to their better chemical reactivity at retarded injection timing, but all fuels produce comparable thermal efficiency at advanced combustion phasing regardless of EGR. In contrast to the high load conditions, there was no increase in NOX emissions for biodiesel at the moderate load condition. It is concluded that although higher CN does not significantly alter ignition delay at moderate to high loads it has a dominant influence on the acceptable injection timing range. Apart from CN effects, fuel oxygen content plays an independent role in reducing some emissions. It is therefore recommended that compensation for fuel ignitability and oxygen content be included in combustion control strategies to optimize emissions and performance of future diesel engines.

Szybist, James P [ORNL; Szymkowicz, Patrick G. [General Motors Corporation; Northrop, William F [General Motors Corporation

2012-01-01T23:59:59.000Z

84

Method of nuclear reactor control using a variable temperature load dependent set point  

SciTech Connect (OSTI)

A method and apparatus for controlling a nuclear reactor in response to a variable average reactor coolant temperature set point is disclosed. The set point is dependent upon percent of full power load demand. A manually-actuated ''droop mode'' of control is provided whereby the reactor coolant temperature is allowed to drop below the set point temperature a predetermined amount wherein the control is switched from reactor control rods exclusively to feedwater flow.

Kelly, J.J.; Rambo, G.E.

1982-04-27T23:59:59.000Z

85

Journal of Energy and Power Engineering 5 (2011) 554-561 Load Torque Compensator for Model Predictive Direct  

E-Print Network [OSTI]

Predictive Direct Current Control in High Power PMSM Drive Systems M. Preindl1, 2 and E. Schaltz2 1. Power Magnet Synchronous Machine (PMSM), it contains an inner current i.e. torque control loop and an outer for Model Predictive Direct Current Control in High Power PMSM Drive Systems 555 Fig. 1 Block diagram

Schaltz, Erik

86

New Directions in Measurement for Software Quality Control  

E-Print Network [OSTI]

of statistical data. In total this provides a framework for quality control in software engineering that is freed1 New Directions in Measurement for Software Quality Control Paul Krause, Bernd Freimut and Witold Suryn Abstract--Assessing and controlling software quality is still an immature discipline. One

Suryn, Witold

87

Refinements and Tests of an Advanced Controller to Mitigate Fatigue Loads in the Controls Advanced Research Turbine: Preprint  

SciTech Connect (OSTI)

Wind turbines are complex, nonlinear, dynamic systems forced by aerodynamic, gravitational, centrifugal, and gyroscopic loads. The aerodynamics of wind turbines are nonlinear, unsteady, and complex. Turbine rotors are subjected to a complicated 3-D turbulent wind inflow field, with imbedded coherent vortices that drive fatigue loads and reduce lifetime. Design of control algorithms for wind turbines must account for multiple control objectives. Future large multi-megawatt turbines must be designed with lighter weight structures, using active controls to mitigate fatigue loads, while maximizing energy capture. Active damping should be added to these dynamic structures to maintain stability for operation in a complex environment. At the National Renewable Energy Laboratory (NREL), we have designed, implemented, and tested advanced controls to maximize energy extraction and reduce structural dynamic loads. These control designs are based on linear models of the turbine that are generated by specialized modeling software. In this paper, we present field test results of an advanced control algorithm to mitigate blade, tower, and drivetrain loads in Region 3.

Wright, A.; Fleming, P.

2010-12-01T23:59:59.000Z

88

Methods and apparatus for controlling respective load currents of multiple series-connected loads  

DOE Patents [OSTI]

A lighting apparatus (100) includes one or more first LEDs (202) for generating a first spectrum of radiation (503), and one or more second LEDs (204) for generating a second different spectrum radiation (505). The first and second LEDs are electrically connected in series between a first node (516A) and a second node (516B), between which a series current (550) flows with the application of an operating voltage (516) across the nodes. A controllable current path (518) is connected in parallel with one or both of the first and second LEDs so as to at least partially divert the series current, such that a first current (552) through the first LED(s) and a second current (554) through the second LED(s) are different. Such current diversion techniques may be employed to compensate for shifts in color or color temperature of generated light during thermal transients, due to different temperature-dependent current-to-flux relationships for different types of LEDs.

Datta, Michael; Lys, Ihor

2014-05-27T23:59:59.000Z

89

Hybrid Control of a Three-Cell Converter Associated to an Inductive Load  

E-Print Network [OSTI]

3519 Hybrid Control of a Three-Cell Converter Associated to an Inductive Load M. Trabelsi, J of the proposed method. - Dynamic Hybrid Systems, Multi-cell converter, Hybrid control, Digital Signal Processing a class of Hybrid Dynamic Systems (HDS). In the field of power electronics, static converters associated

Paris-Sud XI, Université de

90

Microprocessor-controlled photovoltaic-array loading unit  

SciTech Connect (OSTI)

Described is a microprocessor-controlled test system in operation at the Photovoltaics Advanced Systems Test Facility located at Sandia National Laboratories. The test system is designed to measure the total energy output of photovoltaic arrays. The theory, installation, operation, and calibration of the test system are described.

Russell, D.F.

1982-08-01T23:59:59.000Z

91

Gust Load Alleviation for an Aeroelastic System Using Nonlinear Control  

E-Print Network [OSTI]

of gravity h Altitude HCM Angular momentum of a body about its CM vii If Moment of inertia of fuselage about CMf Iw Moment of inertia of wing about CMw k Wing sti ness Lt Lift at tail quarter chord Lw Lift at wing quarter chord m Mass of vehicle, mf +mw Mac... Moment at aerodynamic center mf Mass of fuselage mw Mass of wing NZSP Nonzero setpoint PIF Proportional-integral- lter QPM Quad partition matrix St Tail area Sw Wing area T Thrust u Velocity of system CM in ^b1 direction ud Desired trim velocity of system...

Lucas, Amy Marie

2010-10-12T23:59:59.000Z

92

Building America Case Study: Advanced Boiler Load Monitoring Controllers, Chicago, Illinois (Fact Sheet)  

SciTech Connect (OSTI)

Beyond these initial system efficiency upgrades are an emerging class of Advanced Load Monitoring (ALM) aftermarket controllers that dynamically respond to the boiler load, with claims of 10% to 30% of fuel savings over a heating season. For hydronic boilers specifically, these devices perform load monitoring, with continuous measurement of supply and in some cases return water temperatures. Energy savings from these ALM controllers are derived from dynamic management of the boiler differential, where a microprocessor with memory of past boiler cycles prevents the boiler from firing for a period of time, to limit cycling losses and inefficient operation during perceived low load conditions. These differ from OTR controllers, which vary boiler setpoint temperatures with ambient conditions while maintaining a fixed differential. PARR installed and monitored the performance of one type of ALM controller, the M2G from Greffen Systems, at multifamily sites in the city of Chicago and its suburb Cary, IL, both with existing OTR control. Results show that energy savings depend on the degree to which boilers are over-sized for their load, represented by cycling rates. Also savings vary over the heating season with cycling rates, with greater savings observed in shoulder months. Over the monitoring period, over-sized boilers at one site showed reductions in cycling and energy consumption in line with prior laboratory studies, while less over-sized boilers at another site showed muted savings.

PARR

2014-09-01T23:59:59.000Z

93

Investigation of optimal reactor control for a load-following PWR  

SciTech Connect (OSTI)

Characteristics of optimal load-follow control of PWR plants are investigated in this study. A simple system model that describes main features of physical processes in the system was developed. The system model includes core neutronics with all the spatial dependent feedback effects, Xe-I dynamics, core thermal balances, primary-loop thermal balances, and steam-generator dynamic responses to turbine load changes. An optimal control problem that describes power-level control and power-distribution control problem together and considers all the important system operation limits as hard inquality constraints was formulated. The full-length control rod bank positions, part-length control rod positions, and boron concentration changes were modeled as control variables and turbine load variations were used as the forcing variable. Because modern PWR operating policy is to leave the part-length rods uninserted, the part-length rods were not used as a control variable in the optimal control calculations. The optimal control problem was converted to unconstrained nonlinear optimization problem by using the discretization approximation and the penalty function technique. The converted problem was solved by the nonlinear Gauss-Newton method which showed superior performance over all of the other tested optimization methods.

Yim, M.S.

1987-01-01T23:59:59.000Z

94

Aggregated Modeling and Control of Air Conditioning Loads for Demand Response  

SciTech Connect (OSTI)

Demand response is playing an increasingly important role in the efficient and reliable operation of the electric grid. Modeling the dynamic behavior of a large population of responsive loads is especially important to evaluate the effectiveness of various demand response strategies. In this paper, a highly-accurate aggregated model is developed for a population of air conditioning loads. The model effectively includes statistical information of the population, systematically deals with load heterogeneity, and accounts for second-order dynamics necessary to accurately capture the transient dynamics in the collective response. Based on the model, a novel aggregated control strategy is designed for the load population under realistic conditions. The proposed controller is fully responsive and achieves the control objective without sacrificing end-use performance. The proposed aggregated modeling and control strategies are validated through realistic simulations using GridLAB-D. Extensive simulation results indicate that the proposed approach can effectively manage a large number of air conditioning systems to provide various demand response services, such as frequency regulation and peak load reduction.

Zhang, Wei; Lian, Jianming; Chang, Chin-Yao; Kalsi, Karanjit

2013-06-21T23:59:59.000Z

95

Adaptive optimal control: an algorithm for direct digital control  

SciTech Connect (OSTI)

An algorithm for applying advanced control concepts in heating, ventilating, and air conditioning (HVAC) systems has been developed at the Los Alamos Scientific Laboratory (LASL). The algorithm uses optimal control and is adaptive in nature. Simulations for a solar heated and cooled building indicate that use of this algorithm can accomplish a substantial savings in auxiliary energy consumption. In this paper, the algorithm is described and its application is illustrated with a simple example. Simulation results for a more complex system are also presented. The hardware, including the digital computer, needed to implement this algorithm is briefly discussed.

Farris, D.R.; McDonald, T.E.

1980-01-01T23:59:59.000Z

96

Modeling and Control of Aggregated Air Conditioning Loads Under Realistic Conditions  

SciTech Connect (OSTI)

Demand-side control is playing an increasingly important role in smart grid control strategies. Modeling the dynamical behavior of a large population of appliances is especially important to evaluate the effectiveness of various load control strategies. In this paper, a high accuracy aggregated model is first developed for a population of HVAC units. The model efficiently includes statistical information of the population, systematically deals with heterogeneity, and accounts for a second-order effect necessary to accurately capture the transient dynamics in the collective response. Furthermore, the model takes into account the lockout effect of the compressor in order to represent the dynamics of the system under control more accurately. Then, a novel closed loop load control strategy is designed to track a desired demand curve and to ensure a stable and smooth response.

Chang, Chin-Yao; Zhang, Wei; Lian, Jianming; Kalsi, Karanjit

2013-02-24T23:59:59.000Z

97

Mechanical Loading Regulates NFATc1 and -Catenin Signaling through a GSK3 Control Node*  

E-Print Network [OSTI]

Mechanical Loading Regulates NFATc1 and -Catenin Signaling through a GSK3 Control Node* Received at Stony Brook, Stony Brook, New York 11794 Mechanical stimulation can prevent adipogenic and im- prove of -catenin levels. We asked whether mechanical up-regula- tion of -catenin was critical to reduction

98

Load and Energy Aware Topology Control in Wireless Ad-hoc Networks  

E-Print Network [OSTI]

of (energy efficient) relays. However, using the same set of relays all the time causes some nodes to becomeLoad and Energy Aware Topology Control in Wireless Ad-hoc Networks Tandra Chakraborty, Fazlay Rabbi a family of connected topology with (possibly) disjoint relay sets. Thus, by creating different energy

Rahman, A.K.M. Ashikur

99

Beyond Control Panels: Direct Manipulation for Visual Analytics  

SciTech Connect (OSTI)

Information Visualization strives to provide visual representations through which users can think about and gain insight into information. By leveraging the visual and cognitive systems of humans, complex relationships and phenomena occurring within datasets can be uncovered by exploring information visually. Interaction metaphors for such visualizations are designed to enable users direct control over the filters, queries, and other parameters controlling how the data is visually represented. Through the evolution of information visualization, more complex mathematical and data analytic models are being used to visualize relationships and patterns in data creating the field of Visual Analytics. However, the expectations for how users interact with these visualizations has remained largely unchanged focused primarily on the direct manipulation of parameters of the underlying mathematical models. In this article we present an opportunity to evolve the methodology for user interaction from the direct manipulation of parameters through visual control panels, to interactions designed specifically for visual analytic systems. Instead of focusing on traditional direct manipulation of mathematical parameters, the evolution of the field can be realized through direct manipulation within the visual representation where users can not only gain insight, but also interact. This article describes future directions and research challenges that fundamentally change the meaning of direct manipulation with regards to visual analytics, advancing the Science of Interaction.

Endert, Alexander; Bradel, Lauren; North, Chris

2013-07-19T23:59:59.000Z

100

Load Management for Industry  

E-Print Network [OSTI]

In the electric utility industry, load management provides the opportunity to control customer loads to beneficially alter a utility's load curve Load management alternatives are covered. Load management methods can be broadly classified into four...

Konsevick, W. J., Jr.

1982-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

A new approach to control of xenon spatial oscillation during load follow operation via robust servo systems  

SciTech Connect (OSTI)

The control problem of xenon-induced spatial oscillations of PWR in the axial direction during a load following operation is investigated. The system models are described by a one-group diffusion equation with xenon and temperature feed-backs, iodine and xenon dynamic equations, and heat conductions processes. Control is implemented by the full-length and the part-length control rods and the boron concentration. In order to achieve the control purpose, control models are formulated as the design problem of robust servo systems for distributed parameter reactor systems. The total thermal power and the axial offset are chosen as outputs to be controlled. The control systems consist of servo compensators and stabilizing compensators. They are designed based on the finite-dimensional systems which are constructed by linearizing around steady states, approximately by the Galerkin method, and reducing dimensions via the singular perturbation method. A new and simple computational algorithm to obtain an approximate solution of a steady-state neutron balance is developed via the perturbation method. Some results of numerical simulations are shown in order to discuss the effectiveness of the theory developed in this paper. In particular, it is shown that the designed servo systems are robust against model errors with linearization and modal truncation.

Ukai, Hiroyuki; Iwazumi, Tetsuo (Nagoya Inst. of Technology (Japan). Dept. of Electrical and Computer Engineering)

1994-12-01T23:59:59.000Z

102

Electrically controlling the polarizing direction of a graphene polarizer  

SciTech Connect (OSTI)

We theoretically demonstrate a polarizer with an electrically controllable polarizing direction in the far infrared range using two orthogonal periodic arrays of graphene ribbons, which have different widths and are supported on a dielectric film placed on a thick piece of metal. The operation mechanism originates from the polarization-dependent resonant absorption of the two orthogonal graphene ribbons, which can be respectively controlled with different external bias voltages. The operation wavelength can be expanded to terahertz (THz) radiation.

Zhu, Z. H., E-mail: zzhwcx@163.com; Qin, S. Q. [College of Optoelectronic Science and Engineering, National University of Defense Technology, Changsha 410073 (China); State Key Laboratory of High Performance Computing, National University of Defense Technology, Changsha 410073 (China); Guo, C. C.; Liu, K.; Zhang, J. F.; Ye, W. M.; Yuan, X. D. [College of Optoelectronic Science and Engineering, National University of Defense Technology, Changsha 410073 (China)

2014-09-14T23:59:59.000Z

103

A Sensorless Direct Torque Control Scheme Suitable for Electric Vehicles  

E-Print Network [OSTI]

A Sensorless Direct Torque Control Scheme Suitable for Electric Vehicles Farid Khoucha, Khoudir an Electric Vehicle (EV). The proposed scheme uses an adaptive flux and speed observer that is based on a full is a good candidate for EVs propulsion. Index Terms--Electric vehicle, Induction motor, sensorless drive

Paris-Sud XI, Universit de

104

Direct laser additive fabrication system with image feedback control  

DOE Patents [OSTI]

A closed-loop, feedback-controlled direct laser fabrication system is disclosed. The feedback refers to the actual growth conditions obtained by real-time analysis of thermal radiation images. The resulting system can fabricate components with severalfold improvement in dimensional tolerances and surface finish.

Griffith, Michelle L. (Albuquerque, NM); Hofmeister, William H. (Nashville, TN); Knorovsky, Gerald A. (Albuquerque, NM); MacCallum, Danny O. (Edgewood, NM); Schlienger, M. Eric (Albuquerque, NM); Smugeresky, John E. (Pleasanton, CA)

2002-01-01T23:59:59.000Z

105

Load control in low voltage level of the electricity grid using CHP appliances  

E-Print Network [OSTI]

1 Load control in low voltage level of the electricity grid using µCHP appliances M.G.C. Bosman, V.g.c.bosman@utwente.nl Abstract--The introduction of µCHP (Combined Heat and Power) appliances and other means of distributed on the transformers and, thus, on the grid. In this work we study the influence of introducing µCHP appliances

Al Hanbali, Ahmad

106

A Control Scheme of Enhanced Reliability for Multiple Chiller Plants Using Mergerd Building Cooling Load Measurements  

E-Print Network [OSTI]

of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 much on the accuracy of the chiller model. Measurement accuracy and reliability are essential for the accuracy and reliability of chiller sequencing... Central Chilling Plant Monitoring and control Figure 1. Framework of enhancing building cooling load measurements using data fusion 2 ESL-IC-08-10-31 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany...

Wang, S.; Sun, Y.; Huang, G.; Zhu, N.

107

We Need to Talk... Developing Communicating Power Supplies to Monitor & Control Miscellaneous Electric Loads  

SciTech Connect (OSTI)

Plug loads represent 30percent of total electricity use in residential buildings. Significant energy savings would result from an accurate understanding of which miscellaneous electric devices are using energy, at what time, and in what quantity. Commercially available plug load monitoring and control solutions replace or limit the attached device's native controls - forcing the user to adapt to a separate set of controls associated with the monitoring and control hardware. A better solution is integration of these capabilities at the power supply level. In this paper, we demonstrate a method achieving this integration. Our solution allows unobtrusive power monitoring and control while retaining native device control features. Further, our prototype enables intelligent behaviors by allowing devices to respond to the state of one another automatically. The CPS enables energy savings while demonstrating an added level of functionality to the user. If CPS technology became widespread in devices, a combination of automated and human interactive solutions would enable high levels of energy savings in buildings.

Weber, Andrew; Lanzisera, Steven; Liao, Anna; Meier, Alan

2014-08-11T23:59:59.000Z

108

ACEEE International Journal on Control System and Instrumentation, Vol. 1, No. 1, July 2010 State Of The Art of Electronic Load Controller  

E-Print Network [OSTI]

Of The Art of Electronic Load Controller of Self- Excited Asynchronous Generator Used In Mini / Micro Hydro load controller for a mini / micro hydro power generations using MAT LAB / Simulink software. II characteristics of the turbine and induction machine for mini/micro­ hydro power generation system. He had been

Paris-Sud XI, Université de

109

Method and apparatus for controlling combustor temperature during transient load changes  

DOE Patents [OSTI]

A method and apparatus for controlling the temperature of a combustor in a fuel cell apparatus includes a fast acting air bypass valve connected in parallel with an air inlet to the combustor. A predetermined excess quantity of air is supplied from an air source to a series connected fuel cell and combustor. The predetermined excess quantity of air is provided in a sufficient amount to control the temperature of the combustor during start-up of the fuel processor when the load on the fuel cell is zero and to accommodate any temperature transients during operation of the fuel cell.

Clingerman, Bruce J. (Palmyra, NY); Chalfant, Robert W. (West Henrietta, NY)

2002-01-01T23:59:59.000Z

110

Control system design for maintaining CO{sub 2} capture in IGCC power plants while loading-following  

SciTech Connect (OSTI)

Load-following requirements for future integrated gasification combined cycle (IGCC) power plants with precombustion CO{sub 2} capture are expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. In this work, loadfollowing studies are performed using a comprehensive dynamic model of an IGCC plant with pre-combustion CO{sub 2} capture developed in Aspen Engineering Suite (AES). Considering multiple single-loop controllers for power demand load following, the preferred IGCC control strategy from the perspective of a power producer is gas turbine (GT) lead with gasifier follow. In this strategy, the GT controls the load by manipulating its firing rate while the slurry feed flow to the gasifier is manipulated to control the syngas pressure at the GT inlet. The syngas pressure control is an integrating process with significant time delay mainly because of the large piping and equipment volumes between the gasifier and the GT inlet. A modified proportionalintegralderivative (PID) control is considered for IGCC syngas pressure control. The desired CO{sub 2} capture rate must be maintained while the IGCC plant follows the load. For maintaining the desired CO{sub 2} capture rate, the control performance of PID control is compared with linear model predictive control (LMPC). The results show that the LMPC outperforms PID control for maintaining CO{sub 2} capture rates in an IGCC power plant while load following.

Bhattacharyya, D.; Turton, R.; Zitney, S.

2012-01-01T23:59:59.000Z

111

Decentralized Control of Aggregated Loads for Demand Response Di Guo, Wei Zhang, Gangfeng Yan, Zhiyun Lin, and Minyue Fu  

E-Print Network [OSTI]

Decentralized Control of Aggregated Loads for Demand Response Di Guo, Wei Zhang, Gangfeng Yan of residential responsive loads for vari- ous demand response applications. We propose a general hybrid system and effectively reduce the peak power consumption. I. INTRODUCTION Demand response has the potential to shift

Zhang, Wei

112

Challenges and Potential Solutions for Reducing Climate Control Loads in Conventional and Hybrid Vehicles  

SciTech Connect (OSTI)

The National Renewable Energy Laboratory, a U.S. Department of Energy national laboratory, is collaborating with U.S. automotive manufacturers to develop innovative techniques to reduce national fuel consumption and vehicle tailpipe emissions by reducing vehicle climate control loads. A new U.S. emissions test, the Supplemental Federal Test Procedure (SFTP), will soon begin measuring tailpipe emissions with the air conditioning system operating. Modeled results show that emissions of oxides of nitrogen (NOx) and carbon monoxide (CO) more than double during the air conditioning part of the SFTP. Reducing the transmittance of the glazing can have a greater impact on the cabin soak temperature than ventilating the vehicle during a hot soak. Reducing the amount of outside air can decrease cooling and heating loads but requires that the recirculated air be cleaned. We discuss a photocatalytic oxidation air-cleaning process for removing volatile organic compounds and bioareosols. We conclude with an example of modeling the thermal comfort of the occupants. An auxiliary load increase of only 400 Watts (W) results in a 0.4 km/L (1 mpg) decrease for a conventional 11.9-L/100-km (28-mpg) vehicle. If every vehicle in the United States were to save only 0.4 km/L (1 mpg), $4 billion (U.S. dollars) would be saved annually in gasoline and oil costs. Further information can be found at http://www.ctts.nrel.gov/auxload.html.

Farrington, R.B., Anderson, R., Blake, D.M., Burch, S.D.; Cuddy, M.R., Keyser, M.A., Rugh, J.P.

1999-01-01T23:59:59.000Z

113

DIRECT DECOMPOSITION OF METHANE TO HYDROGEN ON METAL LOADED ZEOLITE CATALYST  

SciTech Connect (OSTI)

The manufacture of hydrogen from natural gas is essential for the production of ultra clean transportation fuels. Not only is hydrogen necessary to upgrade low quality crude oils to high-quality, low sulfur ultra clean transportation fuels, hydrogen could eventually replace gasoline and diesel as the ultra clean transportation fuel of the future. Currently, refinery hydrogen is produced through the steam reforming of natural gas. Although efficient, the process is responsible for a significant portion of refinery CO2 emissions. This project is examining the direct catalytic decomposition of methane as an alternative to steam reforming. The energy required to produce one mole of hydrogen is slightly lower and the process does not require water-gas-shift or pressure-swing adsorption units. The decomposition process does not produce CO2 emissions and the product is not contaminated with CO -- a poison for PEM fuel cells. In this work we examined the direct catalytic decomposition of methane over a metal modified zeolite catalyst and the recovery of catalyst activity by calcination. A favorable production of hydrogen was obtained, when compared with previously reported nickel-zeolite supported catalysts. Reaction temperature had a strong influence on catalyst activity and on the type of carbon deposits. The catalyst utilized at 873 and 973 K could be regenerated without any significant loss of activity, however the catalyst utilized at 1073 K showed some loss of activity after regeneration.

Lucia M. Petkovic; Daniel M. Ginosar; Kyle C. Burch; Harry W. Rollins

2005-08-01T23:59:59.000Z

114

LIDAR Wind Speed Measurement Analysis and Feed-Forward Blade Pitch Control for Load Mitigation in Wind Turbines: January 2010--January 2011  

SciTech Connect (OSTI)

This report examines the accuracy of measurements that rely on Doppler LIDAR systems to determine their applicability to wind turbine feed-forward control systems and discusses feed-forward control system designs that use preview wind measurements. Light Detection and Ranging (LIDAR) systems are able to measure the speed of incoming wind before it interacts with a wind turbine rotor. These preview wind measurements can be used in feed-forward control systems designed to reduce turbine loads. However, the degree to which such preview-based control techniques can reduce loads by reacting to turbulence depends on how accurately the incoming wind field can be measured. The first half of this report examines the accuracy of different measurement scenarios that rely on coherent continuous-wave or pulsed Doppler LIDAR systems to determine their applicability to feed-forward control. In particular, the impacts of measurement range and angular offset from the wind direction are studied for various wind conditions. A realistic case involving a scanning LIDAR unit mounted in the spinner of a wind turbine is studied in depth with emphasis on choices for scan radius and preview distance. The effects of turbulence parameters on measurement accuracy are studied as well. Continuous-wave and pulsed LIDAR models based on typical commercially available units were used in the studies present in this report. The second half of this report discusses feed-forward control system designs that use preview wind measurements. Combined feedback/feed-forward blade pitch control is compared to industry standard feedback control when simulated in realistic turbulent above-rated winds. The feed-forward controllers are designed to reduce fatigue loads, increasing turbine lifetime and therefore reducing the cost of energy. Three feed-forward designs are studied: non-causal series expansion, Preview Control, and optimized FIR filter. The input to the feed-forward controller is a measurement of incoming wind speeds that could be provided by LIDAR. Non-causal series expansion and Preview Control methods reduce blade root loads but increase tower bending in simulation results. The optimized FIR filter reduces loads overall, keeps pitch rates low, and maintains rotor speed regulation and power capture, while using imperfect wind measurements provided by the spinning continuous-wave LIDAR model.

Dunne, F.; Simley, E.; Pao, L.Y.

2011-10-01T23:59:59.000Z

115

A knowledge-based system for control of xenon-induced spatial power oscillations during load-follow operations  

SciTech Connect (OSTI)

As is well known, large pressurized water reactors (PWRs) are subject to xenon-induced axial power oscillations at some time during a given cycle. Attention to this behavior is required during load-follow operations. A knowledge-based system for controlling xenon-induced spatial power oscillations is described. Experience with a limited set of load-follow patterns has demonstrated that the system is capable of providing advice on appropriate control actions. A simulation model, coupled with a rule-learning process, has been found to be a useful way for determining appropriate weights for the rules that relate power patterns and control actions.

Chung, Sun-Kyo; Danofsky, R.A.; Spinrad, B.I.

1988-01-01T23:59:59.000Z

116

Load Reduction of Wind Turbines Using Receding Horizon Control Mohsen Soltani, Rafael Wisniewski, Per Brath, and Stephen Boyd  

E-Print Network [OSTI]

Load Reduction of Wind Turbines Using Receding Horizon Control Mohsen Soltani, Rafael Wisniewski, Per Brath, and Stephen Boyd Abstract-- Large scale wind turbines are lightly damped mechanical% respectively, when compared to a conventional controller. I. INTRODUCTION The size of wind turbine structures

117

Controlling a rabbet load and air/oil seal temperatures in a turbine  

DOE Patents [OSTI]

During a standard fired shutdown of a turbine, a loaded rabbet joint between the fourth stage wheel and the aft shaft of the machine can become unloaded causing a gap to occur due to a thermal mismatch at the rabbet joint with the bearing blower turned on. An open or unloaded rabbet could cause the parts to move relative to each other and therefore cause the rotor to lose balance. If the bearing blower is turned off during a shutdown, the forward air/oil seal temperature may exceed maximum design practice criterion due to "soak-back." An air/oil seal temperature above the established maximum design limits could cause a bearing fire to occur, with catastrophic consequences to the machine. By controlling the bearing blower according to an optimized blower profile, the rabbet load can be maintained, and the air/oil seal temperature can be maintained below the established limits. A blower profile is determined according to a thermodynamic model of the system.

Schmidt, Mark Christopher (Niskayuna, NY)

2002-01-01T23:59:59.000Z

118

Load-side Demand Management in Buildings usingControlled Electric Springs  

E-Print Network [OSTI]

Load-side Demand Management in Buildings using Controlleddemand side management has been a keen topic of interest. Buildings,

Soni, Jayantika; Krishnanand, KR; Panda, Sanjib

2014-01-01T23:59:59.000Z

119

Geometric Control and Differential Flatness of a Quadrotor UAV with a Cable-Suspended Load  

E-Print Network [OSTI]

is established to be a differentially-flat hybrid system with the load position and the quadrotor yaw serving on the configuration space SE(3)?S2 , is obtained by taking variations on manifolds. The quadrotor-load system, see [9]. However, carrying an external load through a gripper increases the inertia of the system

Sreenath, Koushil

120

Direct Digital Control- A Tool for Energy Management of HVAC Systems  

E-Print Network [OSTI]

Direct digital control (DDC) applied to heating, ventilating, and air-conditioning (HVAC) systems corrects many of the deficiencies of conventional automatic temperature control systems. By applying new control sequences, DDC optimizes HVAC energy...

Swanson, K.

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

On Zero Steady-State Error Voltage Control of Single-Phase PWM Inverters With Different Load Types  

SciTech Connect (OSTI)

This paper comprehensively investigates and compares different multiloop linear control schemes for single-phase pulsewidth modulation inverters, both in stationary and synchronous (d-q) frames, by focusing on their steady-state error under different loading conditions. Specifically, it is shown how proportional plus resonant (P + R) control and load current feedback (LCF) control can, respectively, improve the steady-state and transient performance of the inverter, leading to the proposal of a PID + R + LCF control scheme. Furthermore, the LCF control and capacitive current feedback control schemes are shown to be subject to stability issues under second and higher order filter loads. Additionally, the equivalence between the stationary frame and d-q frame controllers is discussed depending on the orthogonal term generation method, and a d-q frame voltage control strategy is proposed eliminating the need for the generation of this orthogonal component. This is achieved while retaining all the advantages of operating in the synchronous d-q frame, i.e., zero steady-state error and ease of implementation. All theoretical findings are validated experimentally using a 1.5 kW laboratory prototype.

Dong, Dong [Virginia Polytechnic Institute and State University (Virginia Tech); Timothy, Thacker [Virginia Polytechnic Institute and State University (Virginia Tech); Burgos, Rolando [ABB; Wang, Fei [ORNL; Boroyevich, Dushan [Virginia Polytechnic Institute and State University (Virginia Tech)

2011-01-01T23:59:59.000Z

122

Toward a Better Understanding of Ducted Rotor Antitorque and Directional Control in Forward Flight  

E-Print Network [OSTI]

of the Core Automatic Flight Control System (CAFCS) mode. Figure 1 shows a sustained, large-amplitude 1-Hz yaw ABSTRACT Despite decades of very successful yaw-control and anti-torque applications, the aerodynamics dramatic. From a handling-qualities perspective, the ducted rotor provides the loads capacity required

123

Water Balance, Salt Loading, and Salinity Control Options of Red Bluff Reservoir, Texas  

E-Print Network [OSTI]

objectives: i) to outline water balance of the reservoir, ii) to establish salt loading trends over the past several decades, and iii) to evaluate the impact of salt loading on salinity of the reservoir and its outflow. We also outlined the needs... presumably has less seepage losses. The study reported here was conducted i) for examining the reservoir water balance of Red Bluff over the past several decades, ii) for establishing salt loading trends, and iii) for evaluating the impact of salt...

Miyamoto, S.; Yuan, Fasong; Anand, Shilpa

124

RESEARCH ARTICLE Controlling speed and direction during interception  

E-Print Network [OSTI]

. Turning rate was controlled using a steering wheel and speed was controlled using a foot pedal (Wann and Land 2000), braking (Lee 1976; Yilmaz and Warren 1995), and fly ball catching (Chapman 1968

125

An Efficient Wide-Speed Direct Torque Control Based on Fuzzy Logic Technique.  

E-Print Network [OSTI]

??Conventional Direct Torque Control (CDTC) system faces the problems of high flux and torque ripples, and has difficulty in improving the performance of dynamic torque (more)

Zhao, Jibo

2012-01-01T23:59:59.000Z

126

Nitrogen Control in Electric Arc Furnace Steelmaking by Direct...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

a new technology with the potential to reduce operating costs and increase productivity in bar and flat-rolled products for the steel industry. Nitrogen Control in...

127

An Evaluation of the HVAC Load Potential for Providing Load Balancing Service  

SciTech Connect (OSTI)

This paper investigates the potential of providing aggregated intra-hour load balancing services using heating, ventilating, and air-conditioning (HVAC) systems. A direct-load control algorithm is presented. A temperature-priority-list method is used to dispatch the HVAC loads optimally to maintain consumer-desired indoor temperatures and load diversity. Realistic intra-hour load balancing signals were used to evaluate the operational characteristics of the HVAC load under different outdoor temperature profiles and different indoor temperature settings. The number of HVAC units needed is also investigated. Modeling results suggest that the number of HVACs needed to provide a {+-}1-MW load balancing service 24 hours a day varies significantly with baseline settings, high and low temperature settings, and the outdoor temperatures. The results demonstrate that the intra-hour load balancing service provided by HVAC loads meet the performance requirements and can become a major source of revenue for load-serving entities where the smart grid infrastructure enables direct load control over the HAVC loads.

Lu, Ning

2012-09-30T23:59:59.000Z

128

Plug-Load Control and Behavioral Change Research in GSA Office Buildings  

SciTech Connect (OSTI)

The U.S. General Services Administration (GSA) owns and leases over 354 million square feet (ft2) of space in over 9,600 buildings [1]. GSA is a leader among federal agencies in aggressively pursuing energy efficiency (EE) opportunities for its facilities and installing renewable energy (RE) systems to provide heating, cooling, and power to these facilities. According to several energy assessments of GSA's buildings conducted by the National Renewable Energy Laboratory (NREL), plug-loads account for approximately 21% of the total electricity consumed within a standard GSA Region 3 office building. This study aims to provide insight on how to effectively manage plug-load energy consumption and attain higher energy and cost savings for plug-loads. As GSA improves the efficiency of its building stock, plug-loads will become an even greater portion of its energy footprint.

Metzger, I.; Cutler, D.; Sheppy, M.

2012-10-01T23:59:59.000Z

129

Collective cargo hauling by a bundle of parallel microtubules: bi-directional motion caused by load-dependent polymerization and depolymerization  

E-Print Network [OSTI]

A microtubule (MT) is a hollow tube of approximately 25 nm diameter. The two ends of the tube are dissimilar and are designated as `plus' and `minus' ends. Motivated by the collective push and pull exerted by a bundle of MTs during chromosome segregation in a living cell, we have developed here a much simplified theoretical model of a bundle of parallel dynamic MTs. The plus-end of all the MTs in the bundle are permanently attached to a movable `wall' by a device whose detailed structure is not treated explicitly in our model. The only requirement is that the device allows polymerization and depolymerization of each MT at the plus-end. In spite of the absence of external force and direct lateral interactions between the MTs, the group of polymerizing MTs attached to the wall create a load force against the group of depolymerizing MTs and vice-versa; the load against a group is shared equally by the members of that group. Such indirect interactions among the MTs gives rise to the rich variety of possible states of collective dynamics that we have identified by computer simulations of the model in different parameter regimes. The bi-directional motion of the cargo, caused by the load-dependence of the polymerization kinetics, is a "proof-of-principle" that the bi-directional motion of chromosomes before cell division does not necessarily need active participation of motor proteins.

Dipanwita Ghanti; Debashish Chowdhury

2015-01-09T23:59:59.000Z

130

Load Monitoring CEC/LMTF Load Research Program  

SciTech Connect (OSTI)

This white paper addresses the needs, options, current practices of load monitoring. Recommendations on load monitoring applications and future directions are also presented.

Huang, Zhenyu; Lesieutre, B.; Yang, Steve; Ellis, A.; Meklin, A.; Wong, B.; Gaikwad, A.; Brooks, D.; Hammerstrom, Donald J.; Phillips, John; Kosterev, Dmitry; Hoffman, M.; Ciniglio, O.; Hartwell, R.; Pourbeik, P.; Maitra, A.; Lu, Ning

2007-11-30T23:59:59.000Z

131

Direct Frequency Comb Spectroscopy and High-Resolution Coherent Control  

E-Print Network [OSTI]

stabilized the inter-pulse period and optical phases of the pulses emitted from a mode-locked Ti we demonstrate the phase sensitive excitation of a closed-loop four-level system in a diamond- and two-photon transitions using direct frequency comb spec- troscopy (DFCS). In particular we phase

Jin, Deborah

132

Surface control bent sub for directional drilling of petroleum wells  

DOE Patents [OSTI]

Directional drilling apparatus for incorporation in a drill string, wherein a lower apparatus section is angularly deviated from vertical by cam action and wherein rotational displacement of the angularly deviated apparatus section is overcome by additional cam action, the apparatus being operated by successive increases and decreases of internal drill string pressure.

Russell, Larry R. (6025 Edgemoor, Suite C, Houston, TX 77081)

1986-01-01T23:59:59.000Z

133

Modified vector control algorithm for increasing partial-load efficiency of fractional-slot concentrated-winding surface PM machines  

SciTech Connect (OSTI)

This paper presents a modified vector control algorithm for a fractional-slot concentrated-winding surface permanent magnet (SPM) machine that has been developed to maximize the machine's partial-load efficiency over a wide range of operating conditions. By increasing the amplitude of the negative d-axis current, the resulting increase in the stator copper losses can be more than offset by the reduction in the iron core losses achieved by lowering the stator d-axis flux amplitude. The effectiveness of this technique has been demonstrated using both analytical models and finite element analysis for a 55-kW (peak) SPM machine design developed for a demanding set of traction drive performance requirements. For this example, the modified control strategy increases the partial-load efficiency at 20% of rated torque by > 6% at 2000 r/min compared to the maximum torque/ampere algorithm, making the machine much more attractive for its intended application.

El-Refaie, Ayman M [ORNL; Jahns, Thomas M [ORNL; Reddy, Patel [University of Wisconsin; McKeever, John W [ORNL

2008-01-01T23:59:59.000Z

134

Mode K - A Core Control Logic for Enhanced Load-Follow Operations of a Pressurized Water Reactor  

SciTech Connect (OSTI)

New core control logic known as Mode K has been developed to enhance the load-follow operation (LFO) capability of a pressurized water reactor. The Mode K reactor regulating system, which actuates control bank movements, consists of two closed control loops, one for the coolant average temperature control and the other for the axial power shape control. Via its peculiar logic for selecting the control banks to be driven, the Mode K controls the coolant average temperature and axial power shape simultaneously and automatically within their allowed operating limits. In this way, the Mode K significantly reduces the operator burden associated with conventional manual power shape control during LFOs. A simple and flexible soluble boron scenario complements the Mode K logic and contributes toward reducing operational burden by its simplicity. The Mode K logic has been implanted in the Korean Next-Generation Reactor, a 1300-MW(electric) class evolutionary nuclear power plant under development in Korea, and various kinds of LFOs including frequency control have been simulated using the Framatome engineering simulator SAPHIR. The simulation results show reasonable core control performance of the Mode K as well as proper behaviors of other major nuclear steam supply system components such as the pressurizer and steam generator.

Oh, Soo-Youl [Korea Atomic Energy Research Institute (Korea, Republic of); Chang, Jonghwa [Korea Atomic Energy Research Institute (Korea, Republic of); Park, Jong-Kyun [Korea Atomic Energy Research Institute (Korea, Republic of); Carrasco, Manuel [Framatome (France)

2001-05-15T23:59:59.000Z

135

Bi-directional power control system for voltage converter  

DOE Patents [OSTI]

A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals. 10 figs.

Garrigan, N.R.; King, R.D.; Schwartz, J.E.

1999-05-11T23:59:59.000Z

136

Bi-directional power control system for voltage converter  

DOE Patents [OSTI]

A control system for a voltage converter includes: a power comparator for comparing a power signal on input terminals of the converter with a commanded power signal and producing a power comparison signal; a power regulator for transforming the power comparison signal to a commanded current signal; a current comparator for comparing the commanded current signal with a measured current signal on output terminals of the converter and producing a current comparison signal; a current regulator for transforming the current comparison signal to a pulse width modulator (PWM) duty cycle command signal; and a PWM for using the PWM duty cycle command signal to control electrical switches of the converter. The control system may further include: a command multiplier for converting a voltage signal across the output terminals of the converter to a gain signal having a value between zero (0) and unity (1), and a power multiplier for multiplying the commanded power signal by the gain signal to provide a limited commanded power signal, wherein power comparator compares the limited commanded power signal with the power signal on the input terminals.

Garrigan, Neil Richard (Niskayuna, NY); King, Robert Dean (Schenectady, NY); Schwartz, James Edward (Slingerlands, NY)

1999-01-01T23:59:59.000Z

137

Emission Control Technology, Performance/Durability -POSTER Effect of Accelerated Ash Loading on Performance of Diesel  

E-Print Network [OSTI]

on Performance of Diesel Particulate Filters and Morphology of Ash Layers Bruce G. Bunting and Todd J. Toops using a single-cylinder diesel engine has been developed for accelerated ash loading in catalyzed and non- catalyzed diesel particular filters (DPF) made of cordierite, SiC and mullite substrate

Pennycook, Steve

138

Directions  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Directions Where We Are Directions The Bradbury Science Museum is located at 1350 Central Avenue Los Alamos, NM 87544 Los Alamos (elevation 7,355 feet) is perched high atop the...

139

Impact of Paint Color on Rest Period Climate Control Loads in Long-Haul Trucks: Preprint  

SciTech Connect (OSTI)

Cab climate conditioning is one of the primary reasons for operating the main engine in a long-haul truck during driver rest periods. In the United States, sleeper cab trucks use approximately 667 million gallons of fuel annually for rest period idling. The U.S. Department of Energy's National Renewable Energy Laboratory's (NREL) CoolCab Project works closely with industry to design efficient thermal management systems for long-haul trucks that minimize engine idling and fuel use while maintaining occupant comfort. Heat transfer to the vehicle interior from opaque exterior surfaces is one of the major heat pathways that contribute to air conditioning loads during long-haul truck daytime rest period idling. To quantify the impact of paint color and the opportunity for advanced paints, NREL collaborated with Volvo Group North America, PPG Industries, and Dometic Environmental Corporation. Initial screening simulations using CoolCalc, NREL's rapid HVAC load estimation tool, showed promising air-conditioning load reductions due to paint color selection. Tests conducted at NREL's Vehicle Testing and Integration Facility using long-haul truck cab sections, 'test bucks,' showed a 31.1% of maximum possible reduction in rise over ambient temperature and a 20.8% reduction in daily electric air conditioning energy use by switching from black to white paint. Additionally, changing from blue to an advanced color-matched solar reflective blue paint resulted in a 7.3% reduction in daily electric air conditioning energy use for weather conditions tested in Colorado. National-level modeling results using weather data from major U.S. cities indicated that the increase in heating loads due to lighter paint colors is much smaller than the reduction in cooling loads.

Lustbader, J.; Kreutzer, C.; Jeffers, M.; Adelman, S.; Yeakel, S.; Brontz, P.; Olson, K.; Ohlinger, J.

2014-02-01T23:59:59.000Z

140

Distributed Voltage and Current Control of Multi-Terminal High-Voltage Direct  

E-Print Network [OSTI]

}@kth.se.) Abstract: High-voltage direct current (HVDC) is a commonly used technology for long-distance power for multi-terminal HVDC (MTDC) systems is proposed. Under certain conditions on the controller gains factor behind long-distance power transmission. High-voltage direct current (HVDC) is a commonly used

Dimarogonas, Dimos

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Sensible and Latent Cooling Load Control Using Centrally-Ducted, Variable-Capacity Space Conditioning Systems in Low Sensible Load Environments  

Broader source: Energy.gov [DOE]

This presentation was given at the Summer 2012 DOE Building America meeting on July 26, 2012, and addressed the question What are the best HVAC solutions for low-load, high performance homes?"

142

Instrument for controlling the application of mechanical loads to biological and bicompatible test subjects  

DOE Patents [OSTI]

Apparatus and methods are disclosed facilitating the application of forces and measurement of dimensions of a test subject. In one arrangement the test subject is coupled to a forcing frame and controlled forces applied thereto. Force applied to the test subject is measured and controlled. A dimensional characteristic of the test subject, such as growth, is measured by a linear variable differential transformer. The growth measurement data can be used to control the force applied. The transducer module receives force and dimensional data from the forcing frame. The transducer module is a separate, microprocessor-based unit that communicates the test data to a controller unit that controls the application of force to the test subject and receives the test data from the transducer module for force control, storage, and/or communication to the user.

Lintilhac, Phillip M. (Shelburne, VT); Vesecky, Thompson B. (Essex Junction, VT)

1995-01-01T23:59:59.000Z

143

Instrument for controlling the application of mechanical loads to biological and bicompatible test subjects  

DOE Patents [OSTI]

An apparatus and methods are disclosed facilitating the application of forces and measurement of dimensions of a test subject. In one arrangement the test subject is coupled to a forcing frame and controlled forces applied thereto. Force applied to the test subject is measured and controlled. A dimensional characteristic of the test subject, such as growth, is measured by a linear variable differential transformer. The growth measurement data can be used to control the force applied. The transducer module receives force and dimensional data from the forcing frame. The transducer module is a separate, microprocessor-based unit that communicates the test data to a controller unit that controls the application of force to the test subject and receives the test data from the transducer module for force control, storage, and/or communication to the user. 8 figs.

Lintilhac, P.M.; Vesecky, T.B.

1995-09-19T23:59:59.000Z

144

Comparing State-Space Multivariable Controls to Multi-SISO Controls for Load Reduction of Drivetrain-Coupled Modes on Wind Turbines through Field-Testing: Preprint  

SciTech Connect (OSTI)

This paper presents the structure of an ongoing controller comparison experiment at NREL's National Wind Technology Center; the design process for the two controllers compared in this phase of the experiment, and initial comparison results obtained in field-testing. The intention of the study is to demonstrate the advantage of using modern multivariable methods for designing control systems for wind turbines versus conventional approaches. We will demonstrate the advantages through field-test results from experimental turbines located at the NWTC. At least two controllers are being developed side-by-side to meet an incrementally increasing number of turbine load-reduction objectives. The first, a multiple single-input, single-output (m-SISO) approach, uses separately developed decoupled and classicially tuned controllers, which is, to the best of our knowledge, common practice in the wind industry. The remaining controllers are developed using state-space multiple-input and multiple-output (MIMO) techniques to explicity account for coupling between loops and to optimize given known frequency structures of the turbine and disturbance. In this first publication from the study, we present the structure of the ongoing controller comparison experiment, the design process for the two controllers compared in this phase, and initial comparison results obtained in field-testing.

Fleming, P. A.; van Wingerden, J. W.; Wright, A. D.

2011-12-01T23:59:59.000Z

145

INTEGRATED DIRECT/INDIRECT ADAPTIVE ROBUST CONTROL OF MULTI-DOF HYDRAULIC ROBOTIC ARMS  

E-Print Network [OSTI]

INTEGRATED DIRECT/INDIRECT ADAPTIVE ROBUST CONTROL OF MULTI-DOF HYDRAULIC ROBOTIC ARMS Amit/indirect adaptive robust control (DIARC) strategy for a hydraulically actuated 3-DOF robotic arm. To avoid the need FOUNDATION GRANT NO. CMS-0600516. draulic robot arm (a scaled down version of an industrial back- hoe

Yao, Bin

146

438 IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, VOL. 15, NO. 3, MAY 2007 Nonlinear Observer-Based Control of Load  

E-Print Network [OSTI]

--Homogeneous charge compression ignition (HCCI) engines, nonlinear feedback control, nonlinear observer, positive semidefinite Lyapunov functions, stability. I. INTRODUCTION HOMOGENEOUS charge compression ignition (HCCI particulate matter (PM) emis- sions due to low cylinder peak temperature (below 1700 K). Control of the HCCI

Stefanopoulou, Anna

147

The role of fuel in determining the high load limit of controlled auto-ignition engines  

E-Print Network [OSTI]

Controlled Auto-Ignition (CAI) engines have the potential to increase fuel economy while lowering nitrogen oxide and soot emissions. One hurdle that is currently being faced is the engine's inability to operate at high ...

Maria, Amir Gamal

2009-01-01T23:59:59.000Z

148

Active Control of Smart Fin Model for Aircraft Buffeting Load Alleviation Applications  

E-Print Network [OSTI]

vertical fin structure, an investigation has been performed to understand the aerodynamic effects of high-speed vortical flows on the dynamic characteristics of vertical fin structures. Extensive wind-tunnel tests have increased with airflow speed as well as the vertical fin angle of attack relative to the airflow direction

Yaman, Yavuz

149

The Effect of 2-Directional Magnetic Biasing Used for Tuning of a Ferrite-Loaded Re-entrant Cavity  

E-Print Network [OSTI]

Cavities that are partially filled with ferrite material provide a tunable resonance frequency by making use of the changing ?-characteristics of ferrites when exposed to an external magnetic bias field. The concept of using either parallel or perpendicular magnetic biasing to reach a certain resonance frequency of a cavity has been known for many years. However, a cavity based on superposition of perpendicular and parallel magnetic fields to obtain improved ferrite characteristics was suggested in [1], but to our knowledge was neither tested nor built. Such a 2-directional biasing is expected to provide a reduction in RF losses for an identical tuning range as compared with the classical 1-directional magnetic bias. We have successfully tested this theory with a measurement set-up consisting of a ferrite-filled cavity, exposed to external biases that allow the clear separation of the two orientations of superposed magnetic bias fields. The outcome is an enlargement of tuning range with high cavity Q and the...

Vollinger, C; Jensen, E

2013-01-01T23:59:59.000Z

150

Direct power control of grid connected PV systems with three level NPC inverter  

SciTech Connect (OSTI)

This paper presents the control of a three-level Neutral Point Clamped (NPC) voltage source inverter for grid connected photovoltaic (PV) systems. The control method used is the Extended Direct Power Control (EDPC), which is a generic approach for Direct Power Control (DPC) of multilevel inverters based on geometrical considerations. Maximum Power Point Tracking (MPPT) algorithms, that allow maximal power conversion into the grid, have been included. These methods are capable of extracting maximum power from each of the independent PV arrays connected to each DC link voltage level. The first one is a conventional MPPT which outputs DC link voltage references to EDPC. The second one is based on DPC concept. This new MPPT outputs power increment references to EDPC, thus avoiding the use of a DC link voltage regulator. The whole control system has been tested on a three-level NPC voltage source inverter connected to the grid and results confirm the validity of the method. (author)

Alonso-Martinez, Jaime; Eloy-Garcia, Joaquin; Arnaltes, Santiago [Dept. of Electrical Engineering, University Carlos III of Madrid, Avda. Universidad 30, 28911 Leganes, Madrid (Spain)

2010-07-15T23:59:59.000Z

151

Instrument for the application of controlled mechanical loads to tissues in sterile culture  

DOE Patents [OSTI]

Apparatus and methods are disclosed facilitating the application of forces and measurement of dimensions of a test subject. In one arrangement the test subject is coupled to a forcing frame and controlled forces applied thereto by a series of guideways and sliders. The sliders, which contact the test subject are in force transmitting relation to a forcing frame. Tension, compression and bending forces can be applied to the test subject. Force applied to the test subject is measured and controlled. A dimensional characteristic of the test subject, such as growth, is measured by a linear variable differential transformer. The growth measurement data can be used to control the force applied. Substantially uniaxial stretching is achieved by placing the test subject on an elastic membrane stretched by an arrangement of members securing the elastic member to the forcing frame. 8 figs.

Lintilhac, P.M.; Vesecky, T.B.

1995-04-18T23:59:59.000Z

152

Instrument for the application of controlled mechanical loads to tissues in sterile culture  

DOE Patents [OSTI]

Apparatus and methods are disclosed facilitating the application of forces and measurement of dimensions of a test subject. In one arrangement the test subject is coupled to a forcing frame and controlled forces applied thereto by a series of guideways and sliders. The sliders, which contact the test subject are in force transmitting relation to a forcing frame. Tension, compression and bending forces can be applied to the test subject. Force applied to the test subject is measured and controlled. A dimensional characteristic of the test subject, such as growth, is measured by a linear variable differential transformer. The growth measurement data can be used to control the force applied. Substantially uniaxial stretching is achieved by placing the test subject on an elastic membrane stretched by an arrangement of members securing the elastic member to the forcing frame.

Lintilhac, Phillip M. (Shelburne, VT); Vesecky, Thompson B. (Essex Junction, VT)

1995-01-01T23:59:59.000Z

153

Abstract--Cascaded nonlinear predictive controller for induction motor drive is presented. The load torque,  

E-Print Network [OSTI]

types of electric machines, exhibits several advantages such as lower cost, reliability, simplicity of the machine. Both controllers are applied in a cascade structure to induction motor. The prediction model law minimizes a quadratic performance index of the predicted tracking error for multivariable system

Paris-Sud XI, Université de

154

Modeling and Control of Aggregated Air Conditioning Loads Under Realistic Conditions  

E-Print Network [OSTI]

heaters are examples of TCLs. They use local hysteresis control to maintain either air or water units and water heaters is developed in [7] using detailed physical models. In all the aforementioned for a large fraction of electric demand. HVAC (Heating, Ventilation and air conditioning) systems and water

Zhang, Wei

155

A comparison of spanwise aerodynamic loads estimated from measured bending moments versus direct pressure measurements on horizontal axis wind turbine blades  

SciTech Connect (OSTI)

Two methods can be used to determine aerodynamic loads on a rotating wind turbine blade. The first is to make direct pressure measurements on the blade surface. This is a difficult process requiring costly pressure instrumentation. The second method uses measured flap bending moments in conjunction with analytical techniques to estimate airloads. This method, called ALEST, was originally developed for use on helicopter rotors and was modified for use on horizontal axis wind turbine blades. Estimating airloads using flap bending moments in much simpler and less costly because measurements can be made with conventional strain gages and equipment. This paper presents results of airload estimates obtained using both methods under a variety of operating conditions. Insights on the limitations and usefulness of the ALEST bending moment technique are also included. 10 refs., 6 figs.

Simms, D A; Butterfield, C P

1991-10-01T23:59:59.000Z

156

Direct  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation Proposed Newcatalyst phasesData FilesShape,PhysicsDileepDirac Charge Dynamcs inDirect

157

Ancillary Frequency Control of Direct Drive Full-Scale Converter Based Wind Power Plants  

E-Print Network [OSTI]

presents a simulation model of a wind power plant based on a MW-level variable speed wind turbineAncillary Frequency Control of Direct Drive Full-Scale Converter Based Wind Power Plants Weihao Hu with a full-scale back-to-back power converter developed in the simulation tool of DIgSILENT Power Factory

Chen, Zhe

158

INCREASED FLEXIBILITY OF TURBO-COMPRESSORS IN NATURAL GAS TRANSMISSION THROUGH DIRECT SURGE CONTROL  

SciTech Connect (OSTI)

The objective of this Direct Surge Control project was to develop a new internal method to avoid surge of pipeline compressors. This method will safely expand the range and flexibility of compressor operations, while minimizing wasteful recycle flow at the lower end of the operating envelope. The approach is to sense the onset of surge with a probe that directly measures re-circulation at the impeller inlet. The signals from the probe are used by a controller to allow operation at low flow conditions without resorting to a predictive method requiring excessive margin to activate a recycle valve. The sensor developed and demonstrated during this project was a simple, rugged, and sensitive drag probe. Experiments conducted in a laboratory compressor clearly showed the effectiveness of the technique. Subsequent field demonstrations indicated that the increase in range without the need to recycle flow was on the order of 19% to 25%. The cost benefit of applying the direct surge control technology appears to be as much as $120 per hour per compressor for operation without the current level of recycle flow. This could amount to approximately $85 million per year for the U.S. Natural Gas Transmission industry, if direct surge control systems are applied to most pipeline centrifugal compressors.

Robert J. McKee; Shane P. Siebenaler; Danny M. Deffenbaugh

2005-02-25T23:59:59.000Z

159

Minimization of DC Reactor and Operation Characteristics of Direct-Power-Controlled Current-Source PWM Rectifier  

E-Print Network [OSTI]

Minimization of DC Reactor and Operation Characteristics of Direct-Power-Controlled Current control; hence inductance of the DC reactor can be reduced. Feasibility of the strategy is verified characteristics of the direct power control based current-source PWM rectifier with a miniaturized DC reactor

Fujimoto, Hiroshi

160

Divertor heat loads in RMP ELM controlled H-mode plasmas on DIII-D*  

SciTech Connect (OSTI)

In this paper the manipulation of power deposition on divertor targets at DIII-D by application of resonant magnetic perturbations (RMPs) is analyzed. It has been found that heat transport shows a different reaction to the applied RMP depending on the plasma pedestal collisionality. At pedestal electron collisionality above 0.5 the heat flux during the ELM suppressed phase is of the same order as the inter-ELM in the non-RMP phase. Below this collisionality value we observe a slight increase of the total power flux to the divertor. This can be caused by much more negative potential at the divertor surface due to hot electrons reaching the divertor surface from the pedestal area and/or so called pump out effect. In the second part we discuss modification of ELM behavior due to the RMP. It is shown, that the width of the deposition pattern in ELMy H-mode depends linearly on the ELM deposited energy, whereas in the RMP phase of the discharge those patterns seem to be controlled by the externally induced magnetic perturbation. D{sub 2} pellets injected into the plasma bulk during ELM-free RMP H-mode lead in some cases to a short term small transients, which have very similar properties to ELMs in the initial RMP-on phase.

Jakubowski, M; Lasnier, C; Schmitz, O; Evans, T; Fenstermacher, M; Groth, M; Watkins, J; Eich, T; Moyer, R; Wolf, R; Baylor, L; Boedo, J; Burrell, K; Frerichs, H; deGrassie, J; Gohil, P; Joseph, I; Lehnen, M; Leonard, A; Petty, C; Pinsker, R; Reiter, D; Rhodes, T; Samm, U; Snyder, P; Stoschus, H; Osborne, T; Unterberg, B; West, W

2008-10-13T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Anticipatory control of turbine generators  

E-Print Network [OSTI]

of Turbine Generators. (Nay 1971) Freddie Laurel Nessec, B. S. E. E, , Texas Tech University; Directed by: Professor J. S . Denison An investigation is made of the use of predicted loads in controlling turbine generators. A perturbation model of a turbine... generator is presented along with typical parameter values. A study is made of the effects of applying control action before a load change occurs. Two predictive control schemes are investi- gated using a load cycle which incorporates both ramp and step...

Messec, Freddie Laurel

1971-01-01T23:59:59.000Z

162

INCREASED FLEXIBILITY OF TURBO-COMPRESSORS IN NATURAL GAS TRANSMISSION THROUGH DIRECT SURGE CONTROL  

SciTech Connect (OSTI)

This preliminary phase 1 report summarizes the background and the work on the ''Increased Flexibility of Turbo-Compressors in Natural Gas Transmission through Direct Surge Control'' project to date. The importance of centrifugal compressors for natural gas transmission is discussed, and the causes of surge and the consequences of current surge control approaches are explained. Previous technology development, including findings from early GMRC research, previous surge detection work, and selected publications, are presented. The project is divided into three Phases to accomplish the project objectives of verifying near surge sensing, developing a prototype surge control system (sensor and controller), and testing/demonstrating the benefits of direct surge control. Specification for the direct surge control sensor and controller developed with guidance from the industry Oversight Committee is presented in detail. Results of CFD modeling conducted to aid in interpreting the laboratory test results are shown and explained. An analysis of the system dynamics identified the data sampling and handling requirements for direct surge control. A detailed design process for surge detection probes has been developed and explained in this report and has been used to prepare drag probes for the laboratory compressor test and the first field test. The surge detection probes prepared for testing have been bench tested and flow tested to determine and calibrate their sensitivity to flow forces as shown in data presented in this report. The surge detection drag probes have been shown to perform as expected and as required to detect approaching surge. Laboratory test results of surge detection in the SwRI centrifugal compressor demonstrated functionality of the surge detection probes and a change in the impeller inlet flow pattern prior to surge. Although the recirculation cannot be detected because of the specific geometry of this compressor, there are changes that indicate the approach of surge that can be detected. Preparations for a field test had been completed at one point in the project. However, a failure of the surge probe wiring just inside the compressor case has caused a delay in the field testing. Repairs for the wiring in the compressor have been scheduled and the field test will take place shortly after the repairs.

Robert J. McKee

2003-05-01T23:59:59.000Z

163

Sensorless Direct Torque Control For Salient Pole PMSM Based on Extended Kalman Filter Fed By AC/DC/AC Converter  

E-Print Network [OSTI]

Sensorless Direct Torque Control For Salient ­ Pole PMSM Based on Extended Kalman Filter Fed By AC is proposed. The Direct Torque Control (DTC) technique for PMSM is receiving increasing attention due on the stochastic intromission, in others words, noise. The PMSM is fed by an indirect power electronic converter

Paris-Sud XI, Université de

164

Dynamic simulation and load-following control of an integrated gasification combined cycle (IGCC) power plant with CO{sub 2} capture  

SciTech Connect (OSTI)

Load-following control of future integrated gasification combined cycle (IGCC) plants with pre-combustion CO{sub 2} capture is expected to be far more challenging as electricity produced by renewable energy is connected to the grid and strict environmental limits become mandatory requirements. To study control performance during load following, a plant-wide dynamic simulation of a coal-fed IGCC plant with CO{sub 2} capture has been developed. The slurry-fed gasifier is a single-stage, downward-fired, oxygen-blown, entrained-flow type with a radiant syngas cooler (RSC). The syngas from the outlet of the RSC goes to a scrubber followed by a two-stage sour shift process with inter-stage cooling. The acid gas removal (AGR) process is a dual-stage physical solvent-based process for selective removal of H{sub 2}S in the first stage and CO{sub 2} in the second stage. Sulfur is recovered using a Claus unit with tail gas recycle to the AGR. The recovered CO{sub 2} is compressed by a split-shaft multistage compressor and sent for sequestration after being treated in an absorber with triethylene glycol for dehydration. The clean syngas is sent to two advanced F-class gas turbines (GTs) partially integrated with an elevated-pressure air separation unit. A subcritical steam cycle is used for heat recovery steam generation. A treatment unit for the sour water strips off the acid gases for utilization in the Claus unit. The steady-state model developed in Aspen Plus is converted to an Aspen Plus Dynamics simulation and integrated with MATLAB for control studies. The results from the plant-wide dynamic model are compared qualitatively with the data from a commercial plant having different configuration, operating condition, and feed quality than what has been considered in this work. For load-following control, the GT-lead with gasifier-follow control strategy is considered. A modified proportionalintegralderivative (PID) control is considered for the syngas pressure control. For maintaining the desired CO{sub 2} capture rate while load-following, a linear model predictive controller (LMPC) is implemented in MATLAB. A combined process and disturbance model is identified by considering a number of model forms and choosing the final model based on an information-theoretic criterion. The performance of the LMPC is found to be superior to the conventional PID control for maintaining CO{sub 2} capture rates in an IGCC power plant while load following.

Bhattacharyya, D,; Turton, R.; Zitney, S.

2012-01-01T23:59:59.000Z

165

Load Management: Opportunity or Calamity?  

E-Print Network [OSTI]

larger now than prior to 1973. Utilities are examining two options which can be termed load management. One option is to control discretionary loads during peak periods. Cycling of residential water heaters or shutting off industrial electric furnaces...

Males, R.; Hassig, N.

1981-01-01T23:59:59.000Z

166

A test platform for measuring the energy efficiency of AC induction motors under various loading conditions and control schemes/  

E-Print Network [OSTI]

A test platform was developed to measure and compare the energy efficiency of an AC induction motor under steady-state and cyclical loading conditions while operating in both a constant speed mode and while performing speed ...

Granata, John A. (John Anthony)

2012-01-01T23:59:59.000Z

167

Distributed Internet-based Load Altering Attacks against Smart Power Grids  

E-Print Network [OSTI]

technology in advanced demand side management and given the growth in power consumption in the computation by compromising direct load control command signals, demand side management price signals, or cloud computation distribution system. Keywords: Smart grid security, Internet-based load altering attacks, demand side

Mohsenian-Rad, Hamed

168

Application of Sleeper Cab Thermal Management Technologies to Reduce Idle Climate Control Loads in Long-Haul Trucks  

SciTech Connect (OSTI)

Each intercity long-haul truck in the U.S. idles approximately 1,800 hrs per year, primarily for sleeper cab hotel loads. Including workday idling, over 2 billion gallons of fuel are used annually for truck idling. NREL's CoolCab project works closely with industry to design efficient thermal management systems for long-haul trucks that keep the cab comfortable with minimized engine idling and fuel use. The impact of thermal load reduction technologies on idle reduction systems were characterized by conducting thermal soak tests, overall heat transfer tests, and 10-hour rest period A/C tests. Technologies evaluated include advanced insulation packages, a solar reflective film applied to the vehicle's opaque exterior surfaces, a truck featuring both film and insulation, and a battery-powered A/C system. Opportunities were identified to reduce heating and cooling loads for long-haul truck idling by 36% and 34%, respectively, which yielded a 23% reduction in battery pack capacity of the idle-reduction system. Data were also collected for development and validation of a CoolCalc HVAC truck cab model. CoolCalc is an easy-to-use, simplified, physics-based HVAC load estimation tool that requires no meshing, has flexible geometry, excludes unnecessary detail, and is less time-intensive than more detailed computer-aided engineering modeling approaches.

Lustbader, J. A.; Venson, T.; Adelman, S.; Dehart, C.; Yeakel, S.; Castillo, M. S.

2012-10-01T23:59:59.000Z

169

Real-Time Forcast Model Analysis of Daily Average Building Load for a Thermal Storage System Control  

E-Print Network [OSTI]

of a building and three real-time building load forecasting models were developed. They are first-order autogressive model, random walk model and linear regression model. Finally, the comparison of results show the random walk model provides the best...

Song, L.; Joo, I. S.; Guwana, S.

170

520 IEEE TRANSACTIONS ON POWER SYSTEMS, VOL. 16, NO. 3, AUGUST 2001 Analysis of Load Frequency Control Performance  

E-Print Network [OSTI]

Control Performance Assessment Criteria George Gross, Fellow, IEEE and Jeong Woo Lee Abstract--This paper

Gross, George

171

Direct control of the small-scale energy balance in 2D fluid dynamics  

E-Print Network [OSTI]

We explore the direct modification of the pseudo-spectral truncation of 2D, incompressible fluid dynamics to maintain a prescribed kinetic energy spectrum. The method provides a means of simulating fluid states with defined spectral properties, for the purpose of matching simulation statistics to given information, arising from observations, theoretical prediction or high fidelity simulation. In the scheme outlined here, Nos\\'e-Hoover thermostats, commonly used in molecular dynamics, are introduced as feedback controls applied to energy shells of the Fourier-discretized Navier-Stokes equations. As we demonstrate in numerical experiments, the dynamical properties (quantified using autocorrelation functions) are only modestly perturbed by our device, while ensemble dispersion is significantly enhanced in comparison with simulations of a corresponding truncation incorporating hyperviscosity.

Frank, Jason; Myerscough, Keith

2014-01-01T23:59:59.000Z

172

Goal-Directed Biped Stepping and Push Recovery with Momentum Control  

E-Print Network [OSTI]

model-predictive control. Computer Graphics Forum, 27(2),neuro- motor control models. Pacific Graphics, 2003. [96]biped walking control. ACM Transactions on Graphics, 29(3),

Wu, Chun-Chih

2011-01-01T23:59:59.000Z

173

IEEE TRANSACTIONS ON ENERGY CONVERSION, VOL. 21, NO. 2, JUNE 2006 619 Direct Torque Control of Induction Motor With Fuzzy Stator  

E-Print Network [OSTI]

--Direct torque control, fuzzy logic, induction mo- tor, stator resistance. I. INTRODUCTION DIRECT torque control logic is proposed. The input variables of the fuzzy logic identifier are the input and output of the low the fuzzy estimator and a classical integrator in a direct torque control (DTC) scheme prove the superiority

Paris-Sud XI, Université de

174

Residential Load Management Program and Pilot  

E-Print Network [OSTI]

In 1986 LCRA embarked on residential load management to control peak summer loads. At that time, LCRA was considered a summer peaking utility, and residential air conditioning and water heating systems were selected for control. The program...

Haverlah, D.; Riordon, K.

1994-01-01T23:59:59.000Z

175

Final Report on Control Algorithm to Improve the Partial-Load Efficiency of Surface PM Machines with Fractional-Slot Concentrated Windings  

SciTech Connect (OSTI)

Surface permanent magnet (SPM) synchronous machines using fractional-slot concentrated windings are being investigated as candidates for high-performance traction machines for automotive electric propulsion systems. It has been shown analytically and experimentally that such designs can achieve very wide constant-power speed ratios (CPSR) [1,2]. This work has shown that machines of this type are capable of achieving very low cogging torque amplitudes as well as significantly increasing the machine power density [3-5] compared to SPM machines using conventional distributed windings. High efficiency can be achieved in this class of SPM machine by making special efforts to suppress the eddy-current losses in the magnets [6-8], accompanied by efforts to minimize the iron losses in the rotor and stator cores. Considerable attention has traditionally been devoted to maximizing the full-load efficiency of traction machines at their rated operating points and along their maximum-power vs. speed envelopes for higher speeds [9,10]. For example, on-line control approaches have been presented for maximizing the full-load efficiency of PM synchronous machines, including the use of negative d-axis stator current to reduce the core losses [11,12]. However, another important performance specification for electric traction applications is the machine's efficiency at partial loads. Partial-load efficiency is particularly important if the target traction application requires long periods of cruising operation at light loads that are significantly lower than the maximum drive capabilities. While the design of the machine itself is clearly important, investigation has shown that this is a case where the choice of the control algorithm plays a critical role in determining the maximum partial-load efficiency that the machine actually achieves in the traction drive system. There is no evidence that this important topic has been addressed for this type of SPM machine by any other authors. This topic takes on even greater significance for fractional-slot concentrated-winding SPM machine designs. In particular, maximizing the torque/power density of this class of SPM machines typically leads to machine designs with high numbers of poles. The resulting high electrical frequencies can easily result in high stator core losses unless special care is taken during the machine design process. The purpose of this report is to discuss a modified vector control algorithm for a fractional-slot concentrated winding SPM machine that has been developed to maximize the machine's partial-load efficiency over a wide range of operating conditions. For purposes of this discussion, a 55 kW (peak) SPM machine designed to meet requirements established in the US FreedomCar program [13] is used as the basis for demonstrating the proposed technique. A combination of closed-form analysis [14] and finite element analysis (FEA) is used during this investigation.

McKeever, John W [ORNL; Reddy, Patel [University of Wisconsin; Jahns, Thomas M [ORNL

2007-05-01T23:59:59.000Z

176

FINAL REPORT ON CONTROL ALGORITHM TO IMPROVE THE PARTIAL-LOAD EFFICIENCY OFSURFACE PM MACHINES WITH FRACTIONAL-SLOT CONCENTRATED WINDINGS  

SciTech Connect (OSTI)

Surface permanent magnet (SPM) synchronous machines using fractional-slot concentrated windings are being investigated as candidates for high-performance traction machines for automotive electric propulsion systems. It has been shown analytically and experimentally that such designs can achieve very wide constant-power speed ratios (CPSR) [1,2]. This work has shown that machines of this type are capable of achieving very low cogging torque amplitudes as well as significantly increasing the machine power density [3-5] compared to SPM machines using conventional distributed windings. High efficiency can be achieved in this class of SPM machine by making special efforts to suppress the eddy-current losses in the magnets [6-8], accompanied by efforts to minimize the iron losses in the rotor and stator cores. Considerable attention has traditionally been devoted to maximizing the full-load efficiency of traction machines at their rated operating points and along their maximum-power vs. speed envelopes for higher speeds [9,10]. For example, on-line control approaches have been presented for maximizing the full-load efficiency of PM synchronous machines, including the use of negative d-axis stator current to reduce the core losses [11,12]. However, another important performance specification for electric traction applications is the machine's efficiency at partial loads. Partial-load efficiency is particularly important if the target traction application requires long periods of cruising operation at light loads that are significantly lower than the maximum drive capabilities. While the design of the machine itself is clearly important, investigation has shown that this is a case where the choice of the control algorithm plays a critical role in determining the maximum partial-load efficiency that the machine actually achieves in the traction drive system. There is no evidence that this important topic has been addressed for this type of SPM machine by any other authors. This topic takes on even greater significance for fractional-slot concentrated-winding SPM machine designs. In particular, maximizing the torque/power density of this class of SPM machines typically leads to machine designs with high numbers of poles. The resulting high electrical frequencies can easily result in high stator core losses unless special care is taken during the machine design process. The purpose of this report is to discuss a modified vector control algorithm for a fractional-slot concentrated winding SPM machine that has been developed to maximize the machine's partial-load efficiency over a wide range of operating conditions. For purposes of this discussion, a 55 kW (peak) SPM machine designed to meet requirements established in the US FreedomCar program [13] is used as the basis for demonstrating the proposed technique. A combination of closed-form analysis [14] and finite element analysis (FEA) is used during this investigation.

Reddy, P.B.; Jahns, T.M.

2007-04-30T23:59:59.000Z

177

New approaches to interfacing thermoelectric generators to the load bus in a nuclear space vehicle  

E-Print Network [OSTI]

reactor and the thermoelectrics. This type oi' system wastes the excess power generated as heat. Heat dissipation in space is very difficult. In the reference design TCAs (thermoelectric converter assembly) and shunt regulators connect directly... ballast load. The variable ballast compensa, tes 1' or the variation of the load. This type of control philosophy is very inefficient. Of the power generated, some is wasted in the variable ballast by heat dissipation. New architectures of controlling...

Brohlin, Paul LeRoy

1988-01-01T23:59:59.000Z

178

Effects of cyclic loading on internal shear strength of unreinforced geosynthetic clay liner  

SciTech Connect (OSTI)

Stress-controlled static and cyclic shear tests were performed by using a direct simple shear device on samples of a geomembrane-supported geosynthetic clay liner (GCL). The dry material showed no degradation in shear strength during cyclic loading as long as the peak shear stress was less than the static shear strength of the GCL with no cyclic loading. Furthermore, cyclic loading slightly densified the dry bentonite and thus increased its shear resistance under subsequent static loading. On the other hand, the shear strength of the hydrated GCL was found to be reduced by cyclic loading. The number of cycles to cause failure decreased with increasing cyclic stress ratio (cyclic shear stress divided by undrained static shear strength); at a cyclic stress ratio of 0.67, failure occurred at 32 cycles of loading, but at a cyclic stress ratio of 0.53, failure did not occur until up to 200 cycles of loading.

Lai, J. [Ghaoyang Univ. of Technology, Taichung (Taiwan, Province of China); Daniel, D.E. [Univ. of Illinois, Urbana, IL (United States). Dept. of Civil Engineering; Wright, S.G. [Univ. of Texas, Austin, TX (United States). Dept. of Civil Engineering

1998-01-01T23:59:59.000Z

179

Hybrid ACOANN-Based Multi-objective SimulationOptimization Model for Pollutant Load Control at Basin Scale  

E-Print Network [OSTI]

Introduction Structural Best Management Practices (BMPs) are often used for sediment and nutrient control and Water Assessment Tool (SWAT) as the simulation module for optimum management of total suspended solids in BMPs, have successfully been used for many years. They are known as the storm water control structures

Pasternack, Gregory B.

180

Abstract--This paper proposes a multi-hour thermal load dispatch model (24-hour time horizon) controlling NOx emission  

E-Print Network [OSTI]

and the Netherlands are among the most advanced countries in relation to environmental pollution control. USA pioneered the Clean Air Act (CAA) in 1963 which established a criteria pollutants list considered dangerous of this pollutant, damage and control, can be obtained from [12]. These developments in US environmental regulations

Catholic University of Chile (Universidad Católica de Chile)

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Goal-directed planning and plan recognition for the sustainable control of homes  

E-Print Network [OSTI]

The goal of this thesis is to design an autonomous control system for the sustainable control of buildings. The control system focusses on satisfying three goals to encourage and facilitate a more sustainable lifestyle for ...

Graybill, Wesley (Wesley Darwin)

2012-01-01T23:59:59.000Z

182

Modelling off Hugoniot Loading Using Ramp Compression in Single Crystal Copper  

SciTech Connect (OSTI)

The application of a ramp load to a sample is a method by which the thermodynamic variables of the high pressure state can be controlled. The faster the loading rate, the higher the entropy and higher the temperature. This paper describes moleculer dynamics (MD) simulations with 25 million atoms which investigate ramp loading of single crystal copper. The simulations followed the propagation of a 300ps ramp load to 3Mbar along the [100] direction copper. The simulations were long enough to allow the wave front to steepen into a shock, at which point the simulated copper sample shock melted.

Hawreliak, J; Remington, B A; Lorenzana, H; Bringa, E; Wark, J

2010-11-29T23:59:59.000Z

183

Optimum Performance of Direct Hydrogen Hybrid Fuel Cell Vehicles  

E-Print Network [OSTI]

with the simple load following strategy (non-hybridizeda Direct-Hydrogen, Load-Following Fuel Cell Vehicle, SAE

Zhao, Hengbing; Burke, Andy

2009-01-01T23:59:59.000Z

184

Direct power control of shunt active filter using high selectivity filter (HSF) under distorted or unbalanced conditions  

E-Print Network [OSTI]

.A. Djaffar) Abstract This paper describes the design of a new configuration of direct power control (DPC inverter voltage vector in order to minimize instantaneous active and reactive power errors using two powers by selecting the optimal switching states of the inverter. Simulation results have proved

Paris-Sud XI, Université de

185

Automatic Control Strategy Development for the Supercritical CO{sub 2} Brayton Cycle for LFR Autonomous Load Following  

SciTech Connect (OSTI)

The supercritical carbon dioxide (S-CO{sub 2}) Brayton cycle is a promising advanced alternative to the Rankine saturated steam cycle and ideal gas Brayton cycle for the energy converters of specific reactor concepts belonging to the U.S. Department of Energy Generation IV Nuclear Energy Systems Initiative. A new plant dynamics analysis computer code has been developed for simulation of the S-CO{sub 2} Brayton cycle coupled to an autonomous Lead-Cooled Fast Reactor (LFR). The plant dynamics code was used to develop an automatic control strategy for the whole plant in response to changes in the demand from the electrical grid. The specific features of the S-CO{sub 2} Brayton cycle that result in limitations on the control range and speed of specific control mechanisms are discussed. Calculations of whole-plant responses to plant operational transients involving step and continuous changes in grid demand are demonstrated. (authors)

Moisseytsev, Anton; Sienicki, James J. [Argonne National Laboratory, 9700 S. Cass Avenue, Argonne, IL, 60439 (United States)

2006-07-01T23:59:59.000Z

186

Control strategy for hydrocarbon emissions in turbocharged direct injection spark ignition engines during cold-start  

E-Print Network [OSTI]

Gasoline consumption and pollutant emissions from transportation are costly and have serious, demonstrated environmental and health impacts. Downsized, turbocharged direct-injection spark ignition (DISI) gasoline engines ...

Cedrone, Kevin David

2013-01-01T23:59:59.000Z

187

Direct comparison of Neural Network, Fuzzy Logic and Model Prediction Variable Structure vortex flow controllers  

E-Print Network [OSTI]

Predictive Variable Structure and Fuzzy Logic based controllers for the same benchmark problem. Evaluation criteria consist of closed-loop system performance, activity level of the VFC nozzles, ease of controller synthesis, time required to synthesize...

Joshi, Praveen Sudhakar

2012-06-07T23:59:59.000Z

188

Plug Load  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 - September 2006Photovoltaic Theory andVelocityPlatinum-LoadingPlug-Load Sign In

189

Neurocontrol of Pressurized Water Reactors in Load-Follow Operations  

SciTech Connect (OSTI)

The neurocontrol technique was applied to control a pressurized water reactor (PWR) in load-follow operations. Generalized learning or direct inverse control architecture was adopted in which the neural network was trained off-line to learn the inverse model of the PWR. Two neural network controllers were designed: One provided control rod position, which controlled the axial power distribution, and the other provided the change in boron concentration, which adjusted core total power. An additional feedback controller was designed so that power tracking capability was improved. The time duration between control actions was 15 min; thus, the xenon effect is limited and can be neglected. Therefore, the xenon concentration was not considered as a controller input variable, which simplified controller design. Center target strategy and minimum boron strategy were used to operate the reactor, and the simulation results demonstrated the effectiveness and performance of the proposed controller.

Lin Chaung; Shen Chihming

2000-12-15T23:59:59.000Z

190

Demand Response: Load Management Programs  

E-Print Network [OSTI]

CenterPoint Load Management Programs CATEE Conference October, 2012 Agenda Outline I. General Demand Response Definition II. General Demand Response Program Rules III. CenterPoint Commercial Program IV. CenterPoint Residential Programs... V. Residential Discussion Points Demand Response Definition of load management per energy efficiency rule 25.181: ? Load control activities that result in a reduction in peak demand, or a shifting of energy usage from a peak to an off...

Simon, J.

2012-01-01T23:59:59.000Z

191

control subjects adapted to the load (P o 0.01; Fig. 3c). The amount of adaptation was assessed on a per subject basis by computing the  

E-Print Network [OSTI]

. Subjects' response to the sudden removal of the load following training was variable. Two of the four

192

Systems & Control Letters 57 (2008) 805812 Contents lists available at ScienceDirect  

E-Print Network [OSTI]

focuses mainly on electro-magneto-hydro-dynamic (EMHD) flow control for hydrodynamic drag reduction use of "ideal" sensors, can improve the efficiency, by reducing control power, for both streamwise [19 reduction is proposed for optimal mixing enhancement by blowing and suction. In [1], they discussed optimal

Krstic, Miroslav

2008-01-01T23:59:59.000Z

193

Direct torque control of permanent magnet synchronous motors with non-sinusoidal back-EMF  

E-Print Network [OSTI]

torque control of permanent magnet synchronous motor (PMSM) with sinusoidal back-EMF is discussed in detail. Secondly, the proposed two-phase conduction mode for DTC of BLDC motors is introduced in the constant torque region. In this control scheme, only...

Ozturk, Salih Baris

2009-05-15T23:59:59.000Z

194

ACTIVE SUSPENSION CONTROL WITH DIRECT-DRIVE TUBULAR LINEAR BRUSHLESS PERMANENT-MAGNET MOTOR  

E-Print Network [OSTI]

-bit A/D channels, four 12-bit A/D channels, eight 16-bit D/A channels. The software used for the actual implementation is Control Desk Developer Version 2.1.1, which connected with Matlab 6.1.0.450 (R12.1) Simulink. This developmental environment... the quarter-car test bed is under closed-loop control, the LBPMM generates the force to attenuate road disturbance, which results in the current flow in each coil set as shown in Figure 9. The current flow in each coil set is monitored from the Control Desk...

Lee, Seungho

2010-01-16T23:59:59.000Z

195

Direct Torque Control for Interior Permanent Magnet Synchronous Motors with Respect to Optimal Efficiency  

E-Print Network [OSTI]

motors (PMSM) increased significantly. Thus, this motor type becomes more and more attractive for drive-axis current of the motor must not be controlled to zero, as it is common with non-salient PMSM. Thus

Paderborn, Universität

196

Improved Load Plan Design Through Integer Programming Based ...  

E-Print Network [OSTI]

The fundamental building block in load planning is a direct trailer, or a direct. ... of shipment and trailer dispatching; (2) integrated consideration of the movement...

2011-12-21T23:59:59.000Z

197

Directly induced swing for closed loop control of electroslag remelting furnace  

DOE Patents [OSTI]

An apparatus and method are disclosed for controlling an electroslag remelting furnace, imposing a periodic fluctuation on electrode drive speed and thereby generating a predictable voltage swing signal. The fluctuation is preferably done by imposition of a sine, square, or sawtooth wave on the drive dc offset signal. 8 figs.

Damkroger, B.

1998-04-07T23:59:59.000Z

198

Wind load reduction for heliostats  

SciTech Connect (OSTI)

This report presents the results of wind-tunnel tests supported through the Solar Energy Research Institute (SERI) by the Office of Solar Thermal Technology of the US Department of Energy as part of the SERI research effort on innovative concentrators. As gravity loads on drive mechanisms are reduced through stretched-membrane technology, the wind-load contribution of the required drive capacity increases in percentage. Reduction of wind loads can provide economy in support structure and heliostat drive. Wind-tunnel tests have been directed at finding methods to reduce wind loads on heliostats. The tests investigated primarily the mean forces, moments, and the possibility of measuring fluctuating forces in anticipation of reducing those forces. A significant increase in ability to predict heliostat wind loads and their reduction within a heliostat field was achieved.

Peterka, J.A.; Hosoya, N.; Bienkiewicz, B.; Cermak, J.E.

1986-05-01T23:59:59.000Z

199

Location Student Fac/Staff Disabled Special OLLI Reserved Electric Carpool Park and Pay 30 Minute Loading Maint/Service State Vehicle Motorcycle Control* S / L** P / T / LD*** Location Total Alumni House 1 1 17 D L P 19  

E-Print Network [OSTI]

Loading Maint/Service State Vehicle Motorcycle Control* S / L** P / T / LD*** Location Total Alumni House = Surface Lot *** P = Permanent, T = Temporary, LD = Leased Structure 5,631 Motorcycle space count is not included in "Total Spaces" count and is an es mate of how many motorcycles can park in each area Surface

de Lijser, Peter

200

Performance consequences of alternating directional control-response compatibility: Evidence from a coal mine shuttle car simulator  

SciTech Connect (OSTI)

This experiment examines the performance of 48 novice participants in a virtual analogy of an underground coal mine shuttle car. Participants were randomly assigned to a compatible condition, an incompatible condition, an alternating condition in which compatibility alternated within and between hands, or an alternating condition in which compatibility alternated between hands. Participants made fewer steering direction errors and made correct steering responses more quickly in the compatible condition. Error rate decreased over time in the incompatible condition. A compatibility effect for both errors and reaction time was also found when the control-response relationship alternated; however, performance improvements over time were not consistent. Isolating compatibility to a hand resulted in reduced error rate and faster reaction time than when compatibility alternated within and between hands. Thus consequences of alternating control-response relationships are higher error rates and slower responses, at least in the early stages of learning. This research highlights the importance of ensuring consistently compatible human-machine directional control-response relationships.

Zupanc, C.M.; Burgess-Limerick, R.J.; Wallis, G. [University of Queensland, St Lucia, Qld. (Australia)

2007-08-15T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Active electron energy distribution function control in direct current discharge using an auxiliary electrode  

SciTech Connect (OSTI)

The electron energy distribution functions are studied in the low voltage dc discharge with a constriction, which is a diaphragm with an opening. The dc discharge glows in helium and is sustained by the electron current emitted from a heated cathode. We performed kinetic simulations of dc discharge characteristics and electron energy distribution functions for different gas pressures (0.8 Torr-4 Torr) and discharge current of 0.1 A. The results of these simulations indicate the ability to control the shape of the electron energy distribution functions by variation of the diaphragm opening radius.

Schweigert, I. V. [Institute of Theoretical and Applied Mechanics, Novosibirsk 630090 (Russian Federation) [Institute of Theoretical and Applied Mechanics, Novosibirsk 630090 (Russian Federation); George Washington University, Washington, DC 20052 (United States); Kaganovich, I. D. [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States)] [Princeton Plasma Physics Laboratory, Princeton, NJ 08543 (United States); Demidov, V. I. [West Virginia University, Morgantown, WV 26506 (United States) [West Virginia University, Morgantown, WV 26506 (United States); St. Petersburg State University, St. Petersburg (Russian Federation)

2013-10-15T23:59:59.000Z

202

Nonlocal control of electron temperature in short direct current glow discharge plasma  

SciTech Connect (OSTI)

To demonstrate controlling the electron temperature in nonlocal plasma, experiments have been performed on a short (without positive column) dc glow discharge with a cold cathode by applying different voltages to the conducting discharge wall. The experiments have been performed for low-pressure noble gas discharges. The applied voltage can modify trapping the energetic electrons emitted from the cathode sheath and arising from the atomic and molecular processes in the plasma within the device volume. This phenomenon results in the energetic electrons heating the slow plasma electrons, which consequently modifies the electron temperature. Furthermore, a numerical model of the discharge has demonstrated the electron temperature modification for the above case.

Demidov, V. I. [Department of Optics and Spectroscopy, St. Petersburg State University, St. Petersburg 199034 (Russian Federation); International Laboratory Nonlocal Plasma in Nanotechnology and Medicine, ITMO University, Kronverkskiy pr. 49, St. Petersburg 197101 (Russian Federation); Department of Physics and Astronomy, West Virginia University, Morgantown, West Virginia 26506 (United States); Kudryavtsev, A. A.; Stepanova, O. M. [Department of Optics and Spectroscopy, St. Petersburg State University, St. Petersburg 199034 (Russian Federation); Kurlyandskaya, I. P. [International Laboratory Nonlocal Plasma in Nanotechnology and Medicine, ITMO University, Kronverkskiy pr. 49, St. Petersburg 197101 (Russian Federation); St. Petersburg University of State Fire Service of EMERCOM RF, Murmansk Branch, Murmansk 183040 (Russian Federation)

2014-09-15T23:59:59.000Z

203

Admixture enhanced controlled low-strength material for direct underwater injection with minimal cross-contamination  

SciTech Connect (OSTI)

Commercially available admixtures have been developed for placing traditional concrete products under water. This paper evaluates adapting anti-washout admixture (AWA) and high range water reducing admixture (HRWRA) products to enhance controlled low-strength materials (CLSMs) for underwater placement. A simple experimental scale model (based on dynamic and geometric similitude) of typical grout pump emplacement equipment has been developed to determine the percentage of cementing material washed out. The objective of this study was to identify proportions of admixtures and underwater CLSM emplacement procedures which would minimize the cross-contamination of the displaced water while maintaining the advantages of CLSM. Since the displaced water from radioactively contaminated systems must be subsequently treated prior to release to the environment, the amount of cross-contamination is important for cases in which cementing material could form hard sludges in a water treatment facility and contaminate the in-place CLSM stabilization medium.

Hepworth, H.K.; Davidson, J.S.; Hooyman, J.L.

1997-03-01T23:59:59.000Z

204

Interaction of toluene with two-color asymmetric laser fields: Controlling the directional emission of molecular hydrogen fragments  

SciTech Connect (OSTI)

The interaction of toluene with strong asymmetric two-color laser irradiation of 40 fs duration is studied by means of Time of flight mass spectrometry. Highly energetic H{sub 2}{sup +} and H{sub 3}{sup +} fragment ions are produced through an isomerization process taking place within transient multiply charged parent ions. Comparative study of deuterium labeled toluene isotopes enables the discrimination between molecular hydrogen fragments formed exclusively within the CH{sub 3}- part from those that require hydrogen atom exchange between the former and the phenyl moiety. It is demonstrated that by manipulating the relative phase of the ?/2? field components the selective ionization of oriented toluene molecules can be used as a tool to control the directional emission of the H{sub 2}{sup +}, H{sub 3}{sup +} species.

Kaziannis, S.; Kotsina, N.; Kosmidis, C. [Department of Physics, Atomic and Molecular Physics Laboratory, University of Ioannina, University Campus, Ioannina GR-45110 (Greece)

2014-09-14T23:59:59.000Z

205

High speed flux feedback for tuning a universal field oriented controller capable of operating in direct and indirect field orientation modes  

DOE Patents [OSTI]

The direct (d) and quadrature (q) components of flux, as sensed by flux sensors or determined from voltage and current measurements in a direct field orientation scheme, are processed rapidly and accurately to provide flux amplitude and angular position values for use by the vector rotator of a universal field-oriented (UFO) controller. Flux amplitude (linear or squared) is provided as feedback to tune the UFO controller for operation in direct and indirect field orientation modes and enables smooth transitions from one mode to the other. 3 figs.

De Doncker, R.W.A.A.

1992-09-01T23:59:59.000Z

206

High speed flux feedback for tuning a universal field oriented controller capable of operating in direct and indirect field orientation modes  

SciTech Connect (OSTI)

The direct (d) and quadrature (q) components of flux, as sensed by flux sensors or determined from voltage and current measurements in a direct field orientation scheme, are processed rapidly and accurately to provide flux amplitude and angular position values for use by the vector rotator of a universal field-oriented (UFO) controller. Flux amplitude (linear or squared) is provided as feedback to tune the UFO controller for operation in direct and indirect field orientation modes and enables smooth transitions from one mode to the other.

De Doncker, Rik W. A. A. (Schenectady, NY)

1992-01-01T23:59:59.000Z

207

A case study review of technical and technology issues for transition of a utility load management program to provide system reliability resources in restructured electricity markets  

SciTech Connect (OSTI)

Utility load management programs--including direct load control and interruptible load programs--were employed by utilities in the past as system reliability resources. With electricity industry restructuring, the context for these programs has changed; the market that was once controlled by vertically integrated utilities has become competitive, raising the question: can existing load management programs be modified so that they can effectively participate in competitive energy markets? In the short run, modified and/or improved operation of load management programs may be the most effective form of demand-side response available to the electricity system today. However, in light of recent technological advances in metering, communication, and load control, utility load management programs must be carefully reviewed in order to determine appropriate investments to support this transition. This report investigates the feasibility of and options for modifying an existing utility load management system so that it might provide reliability services (i.e. ancillary services) in the competitive markets that have resulted from electricity industry restructuring. The report is a case study of Southern California Edison's (SCE) load management programs. SCE was chosen because it operates one of the largest load management programs in the country and it operates them within a competitive wholesale electricity market. The report describes a wide range of existing and soon-to-be-available communication, control, and metering technologies that could be used to facilitate the evolution of SCE's load management programs and systems to provision of reliability services. The fundamental finding of this report is that, with modifications, SCE's load management infrastructure could be transitioned to provide critical ancillary services in competitive electricity markets, employing currently or soon-to-be available load control technologies.

Weller, G.H.

2001-07-15T23:59:59.000Z

208

Modeling and Optimization of PEMFC Systems and its Application to Direct Hydrogen Fuel Cell Vehicles  

E-Print Network [OSTI]

a Direct-Hydrogen, Load-Following Fuel Cell Vehicle, SAEversus a Direct-Hydrogen Load-Following Fuel Cell Vehicle,vehicle model of a load-following direct hydrogen fuel cell

Zhao, Hengbing; Burke, Andy

2008-01-01T23:59:59.000Z

209

Cooling load differences between radiant and air systems  

E-Print Network [OSTI]

radiant heat transfer for cooling load calculation.heat gain is well recognized by cooling load calculationload calculation approach for radiant systems, Corgnati [17] also tackled the direct radiant heat

Feng, Jingjuan Dove; Schiavon, Stefano; Bauman, Fred

2013-01-01T23:59:59.000Z

210

Load Management and Houston Lighting and Power Co.  

E-Print Network [OSTI]

Defining Load Management as influencing of customer loads in order to shift the time use of electric power and energy, encompasses a broad spectrum of activities at Houston Lighting & Power Company. This paper describes those activities by directing...

Drawe, R. G.; Ramsay, I. M.

1984-01-01T23:59:59.000Z

211

Load Alleviation on Wind Turbine Blades using Variable Airfoil Geometry  

E-Print Network [OSTI]

Load Alleviation on Wind Turbine Blades using Variable Airfoil Geometry Peter Bjrn Andersen, Mac Loads, Trailing Edge Flaps, PID control, Signal Noise. 1 Introduction Wind turbine blades are subject to 40% when signal noise is added to the control. Keywords: Wind Turbine, Load Alleviation, Fatigue

212

Modeling and Estimating Current Harmonics of Variable Electronic Loads  

E-Print Network [OSTI]

This paper develops a model for relating input current harmonic content to real power consumption for variable electronic loads, specifically for loads' actively controlled inverters energized by an uncontrolled rectification ...

Wichakool, Warit

213

COLLINS, KELLY ALYSSA. A Field Evaluation of Four Types of Permeable Pavement with Respect to Water Quality Improvement and Flood Control. (Under the direction of  

E-Print Network [OSTI]

to Water Quality Improvement and Flood Control. (Under the direction of Dr.William F. Hunt.) In North were compared to permeable pavement exfiltrate quality for pH and concentrations of total nitrogen (TN capabilities in reducing runoff, but are not credited for improving water quality. To further test

Hunt, William F.

214

Design and implementation of a multiaxial loading capability during heating on an engineering neutron diffractometer  

SciTech Connect (OSTI)

A gripping capability was designed, implemented, and tested for in situ neutron diffraction measurements during multiaxial loading and heating on the VULCAN engineering materials diffractometer at the spallation neutron source at Oak Ridge National Laboratory. The proposed capability allowed for the acquisition of neutron spectra during tension, compression, torsion, and/or complex loading paths at elevated temperatures. The design consisted of age-hardened, Inconel{sup } 718 grips with direct attachment to the existing MTS load frame having axial and torsional capacities of 100 kN and 400 Nm, respectively. Internal cooling passages were incorporated into the gripping system for fast cooling rates during high temperature experiments up to ?1000 K. The specimen mounting couplers combined a threaded and hexed end-connection for ease of sample installation/removal without introducing any unwanted loads. Instrumentation of this capability is documented in this work along with various performance parameters. The gripping system was utilized to investigate deformation in NiTi shape memory alloys under various loading/control modes (e.g., isothermal, isobaric, and cyclic), and preliminary results are presented. The measurements facilitated the quantification of the texture, internal strain, and phase fraction evolution in NiTi shape memory alloys under various loading/control modes.

Benafan, O., E-mail: othmane.benafan@nasa.gov [NASA Glenn Research Center, Structures and Materials Division, Cleveland, Ohio 44135 (United States); Advanced Materials Processing and Analysis Center, Materials Science and Engineering Department, University of Central Florida, Orlando, Florida 32816 (United States); Padula, S. A. [NASA Glenn Research Center, Structures and Materials Division, Cleveland, Ohio 44135 (United States); Skorpenske, H. D.; An, K. [Spallation Neutron Source, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Vaidyanathan, R. [Advanced Materials Processing and Analysis Center, Materials Science and Engineering Department, University of Central Florida, Orlando, Florida 32816 (United States)

2014-10-15T23:59:59.000Z

215

Load sensing system  

DOE Patents [OSTI]

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast

Sohns, Carl W. (Oak Ridge, TN); Nodine, Robert N. (Knoxville, TN); Wallace, Steven Allen (Knoxville, TN)

1999-01-01T23:59:59.000Z

216

Loading margin Stable operating  

E-Print Network [OSTI]

Linear approximation at p1 Actual loading margin Loadingmargin Parameter p p1 p2 p3 IEEE Transactions collapse. Linear and quadratic estimates to the variation of the loading margin with respect to any sys power support, wheeling, load model param- eters, line susceptance, and generator dispatch. The accuracy

217

PHYSICAL REVIEW A 83, 053617 (2011) Controlling directed transport of matter-wave solitons using the ratchet effect  

E-Print Network [OSTI]

the ratchet effect M. Rietmann,1,* R. Carretero-Gonzalez,1 and R. Chacon2 1 Nonlinear Dynamical Systems that the dependence of the directed soliton current on the number of atoms is a consequence of the ratchet The ratchet effect, that is, directed transport without any net external force [1,2], has attracted enormous

Carretero, Ricardo

2011-01-01T23:59:59.000Z

218

Impact of carbohydrate restriction with and without fatty acid loading on myocardial 18F-FDG uptake during PET: A randomized controlled trial  

E-Print Network [OSTI]

18 F-FDG uptake during PET: A randomized controlled trialmay enhance 18 F-FDG-PET-based imaging of small, in?amedpreparations prior to 18 F-FDG-PET. Methods and Results. We

Cheng, Victor Y.; Slomka, Piotr J.; Ahlen, Marie; Thomson, Louise E.; Waxman, Alan D.; Berman, Daniel S.

2010-01-01T23:59:59.000Z

219

Proportional EMG Control of Ankle Plantar Flexion in a Powered Transtibial Prosthesis  

E-Print Network [OSTI]

Proportional EMG Control of Ankle Plantar Flexion in a Powered Transtibial Prosthesis Jing Wang plantar flexion in the trailing prosthetic ankle increases. Not surprisingly, excessive loads to control a powered ankle- foot prosthesis using a volitional electromyographic (EMG) control to directly

Herr, Hugh

220

air conditioning load: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

J.; Deying, L. 2006-01-01 2 Aggregated Modeling and Control of Air Conditioning Loads for Demand Response Computer Technologies and Information Sciences Websites Summary: 1...

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

air conditioning loads: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Websites Summary: 1 Aggregated Modeling and Control of Air Conditioning Loads for Demand Response Wei Zhang, Member, IEEE Abstract--Demand response is playing an...

222

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network [OSTI]

water heater (EWH) load control program operated as part of PJM Interconnections Demand ResponseDemand Response Economic and Emergency Load Response Programs Electric Thermal Storage Electric Water Heaterwater pumps and electric thermal storage space heaters. The CSP is also participating in PJMs pilot Demand Response

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

223

Load apparatus and method for bolt-loaded compact tension test specimen  

DOE Patents [OSTI]

A bolt-loaded compact tension test specimen load apparatus includes: (a) a body having first and second opposing longitudinal ends, the first end comprising an externally threaded portion sized to be threadedly received within the test specimen threaded opening; (b) a longitudinal loading rod having first and second opposing longitudinal ends, the loading rod being slidably received in a longitudinal direction within the body internally through the externally threaded portion and slidably extending longitudinally outward of the body first longitudinal end; (c) a force sensitive transducer slidably received within the body and positioned to engage relative to the loading rod second longitudinal end; and (d) a loading bolt threadedly received relative to the body, the loading bolt having a bearing end surface and being positioned to bear against the transducer to forcibly sandwich the transducer between the loading bolt and loading rod. Also disclosed is a method of in situ determining applied force during crack propagation in a bolt-loaded compact tension test specimen. 6 figs.

Buescher, B.J. Jr.; Lloyd, W.R.; Ward, M.B.; Epstein, J.S.

1997-02-04T23:59:59.000Z

224

Load apparatus and method for bolt-loaded compact tension test specimen  

DOE Patents [OSTI]

A bolt-loaded compact tension test specimen load apparatus includes: a) a body having first and second opposing longitudinal ends, the first end comprising an externally threaded portion sized to be threadedly received within the test specimen threaded opening; b) a longitudinal loading rod having first and second opposing longitudinal ends, the loading rod being slidably received in a longitudinal direction within the body internally through the externally threaded portion and slidably extending longitudinally outward of the body first longitudinal end; c) a force sensitive transducer slidably received within the body and positioned to engage relative to the loading rod second longitudinal end; and d) a loading bolt threadedly received relative to the body, the loading bolt having a bearing end surface and being positioned to bear against the transducer to forcibly sandwich the transducer between the loading bolt and loading rod. Also disclosed is a method of in situ determining applied force during crack propagation in a bolt-loaded compact tension test specimen.

Buescher, Jr., Brent J. (Idaho Falls, ID); Lloyd, W. Randolph (Idaho Falls, ID); Ward, Michael B. (Idaho Falls, ID); Epstein, Jonathan S. (Idaho Falls, ID)

1997-01-01T23:59:59.000Z

225

Load regulating expansion fixture  

DOE Patents [OSTI]

A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils is disclosed. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components. 1 fig.

Wagner, L.M.; Strum, M.J.

1998-12-15T23:59:59.000Z

226

Load regulating expansion fixture  

DOE Patents [OSTI]

A free standing self contained device for bonding ultra thin metallic films, such as 0.001 inch beryllium foils. The device will regulate to a predetermined load for solid state bonding when heated to a bonding temperature. The device includes a load regulating feature, whereby the expansion stresses generated for bonding are regulated and self adjusting. The load regulator comprises a pair of friction isolators with a plurality of annealed copper members located therebetween. The device, with the load regulator, will adjust to and maintain a stress level needed to successfully and economically complete a leak tight bond without damaging thin foils or other delicate components.

Wagner, Lawrence M. (San Jose, CA); Strum, Michael J. (San Jose, CA)

1998-01-01T23:59:59.000Z

227

Load sensing system  

DOE Patents [OSTI]

A load sensing system inexpensively monitors the weight and temperature of stored nuclear material for long periods of time in widely variable environments. The system can include an electrostatic load cell that encodes weight and temperature into a digital signal which is sent to a remote monitor via a coaxial cable. The same cable is used to supply the load cell with power. When multiple load cells are used, vast inventories of stored nuclear material can be continuously monitored and inventoried of minimal cost. 4 figs.

Sohns, C.W.; Nodine, R.N.; Wallace, S.A.

1999-05-04T23:59:59.000Z

228

TRIAC/SCR proportional control circuit  

DOE Patents [OSTI]

A power controller device which uses a voltage-to-frequency converter in conjunction with a zero crossing detector to linearly and proportionally control AC power being supplied to a load. The output of the voltage-to frequency converter controls the "reset" input of a R-S flip flop, while an "0" crossing detector controls the "set" input. The output of the flip flop triggers a monostable multivibrator controlling the SCR or TRIAC firing circuit connected to the load. Logic gates prevent the direct triggering of the multivibrator in the rare instance where the "reset" and "set" inputs of the flip flop are in coincidence. The control circuit can be supplemented with a control loop, providing compensation for line voltage variations.

Hughes, Wallace J. (Boston Lake, NY)

1999-01-01T23:59:59.000Z

229

TRIAC/SCR proportional control circuit  

DOE Patents [OSTI]

A power controller device is disclosed which uses a voltage-to-frequency converter in conjunction with a zero crossing detector to linearly and proportionally control AC power being supplied to a load. The output of the voltage-to frequency converter controls the ``reset`` input of a R-S flip flop, while an ``0`` crossing detector controls the ``set`` input. The output of the flip flop triggers a monostable multivibrator controlling the SCR or TRIAC firing circuit connected to the load. Logic gates prevent the direct triggering of the multivibrator in the rare instance where the ``reset`` and ``set`` inputs of the flip flop are in coincidence. The control circuit can be supplemented with a control loop, providing compensation for line voltage variations. 9 figs.

Hughes, W.J.

1999-04-06T23:59:59.000Z

230

Composition Control in the Direct Laser-Deposition Process R.R. UNOCIC and J.N. DuPONT  

E-Print Network [OSTI]

in the LENS system makes this feasible. Dissimilar powder materials can be placed into separate powder hoppers the composition within each layer deposit. Previous work in the closely related process of fusion welding has changes in a continuous manner from one target value to another. However, with a direct metal- deposition

DuPont, John N.

231

16 Load Data Cleansing and Bus Load  

E-Print Network [OSTI]

-to-day operations, system analysis in smart grids, system visualization, system performance reliability, energy..............................................................................................................397 #12;376 Smart Grids The load forecast generally provides annual peak values for the whole system saving, and accuracy in system planning [14]. * This work is partly supported by a collaborative

Wang, Ke

232

Automated fuel pin loading system  

DOE Patents [OSTI]

An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inserted as a batch prior to welding of end caps by one of two disclosed welding systems.

Christiansen, David W. (Kennewick, WA); Brown, William F. (West Richland, WA); Steffen, Jim M. (Richland, WA)

1985-01-01T23:59:59.000Z

233

MCO loading and cask loadout technical manual  

SciTech Connect (OSTI)

A compilation of the technical basis for loading a multi-canister overpack (MCO) with spent nuclear fuel and then placing the MCO into a cask for shipment to the Cold Vacuum Drying Facility. The technical basis includes a description of the process, process technology that forms the basis for loading alternatives, process control considerations, safety considerations, equipment description, and a brief facility structure description.

PRAGA, A.N.

1998-10-01T23:59:59.000Z

234

contingency Nominal loading margin  

E-Print Network [OSTI]

is estimated. First a nose curve is computed by continuation to obtain a nominal loading margin. Then linear and the very fast computation of the linear estimates. Keywords: Power system security, contingency analy- sis formulas derived in [4]. The computations are summarized: 1 A pattern of load increase, generator dispatch

235

Study of the Stability of a Direct Stator Current Controller for a Doubly-Fed Induction Machine using the Complex  

E-Print Network [OSTI]

to renewable energy (wind farms in particular). The proposed control algorithm offers the advantages of proven large speed variations around the synchronous speed. Another advantage is that the power electronic voltage is adopted. This uncommon approach allows for a decomposition of the active and reactive powers

Batlle, Carles

236

Direct control based on sliding mode techniques for multicell serial L. Amet, M. Ghanes and J. P. Barbot  

E-Print Network [OSTI]

. This is carried out thanks to the de- velopments of power semiconductors and new energy conver- sion systems. To assume the increase of power consumption, inverters have to be controlled more efficiently and increase their power. A solution to obtain both conditions is to use multilevel inverters [2] which combines switching

Paris-Sud XI, Université de

237

Journal of Process Control 23 (2013) 5869 Contents lists available at SciVerse ScienceDirect  

E-Print Network [OSTI]

performance is here quantified using the state drift criterion and the method is evaluated on two distillation column case studies with one, two or more closed loops. © 2012 Elsevier Ltd. All rights reserved. 1.g. using MPC with no lower-layer PID controllers) would be optimal from a theoretical point of view

Skogestad, Sigurd

238

Directives Tools  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

Useful links and resources for Directives Writers, Directives Point of Contact (DPCs), Subject Matter Experts (SMEs), and Draft Directive Reviewers.

239

Scalable Load Distribution and Load Balancing for Dynamic Parallel Programs  

E-Print Network [OSTI]

shown that the algorithm scales according to the definition of scalability given following. LoadScalable Load Distribution and Load Balancing for Dynamic Parallel Programs E. Berger and J. C of an integrated load distribution-load balancing algorithm which was targeted to be both efficient and scalable

Berger, Emery

240

Independent review of estimated load reductions for PJM's small customer load response pilot project  

SciTech Connect (OSTI)

This study describes the results of a low-cost approach used to measure reported load reductions from a residential electric water heater (EWH) load control program operated as part of PJM Interconnection's Demand Response small customer pilot program. Lawrence Berkeley National Laboratory (LBNL) conducted this independent review of the engineering estimates for EWH load control reported by a Curtailment Service Provider (CSP) at PJM's request. LBNL employed low-cost measurement and verification (M&V) approaches that utilized existing interval metering equipment to monitor results for a series of load control tests. The CSP collected hourly load data for two substations and several hundred households over a six-week period in October and November 2003. During this time period, the CSP operated its electric water heater load control program during pre-specified test periods in the morning, afternoon and early evening. LBNL then analyzed substation and premise-level data from these tests in order to verify the diversified demand reductions claimed by the CSP for customers participating in the EWH load control program. We found that the observed load reductions for the premise-level data aggregated over all households in the two participating electric cooperatives were, respectively, 40 percent-60 percent less and 3 percent less-10 percent higher than the estimated diversified demand reduction values assumed by the CSP, depending on whether observed or normalized results are considered. We also analyzed sub-station level data and found that the observed load reductions during the test periods were significantly lower than expected, although confounding influences and operational problems signifiogram during pre-specified test periods in the morning, afternoon and early evening. LBNL then analyzed substation and premise-level data from these tests in order to verify the diversified demand reductions claimed by the CSP for customers participating in the EWH load control program. We found that the observed load reductions for the premise-level data aggregated over all households in the two participating electric cooperatives were, respectively, 40 percent-60 percent less and 3 percent less-10 percent higher than the estimated diversified demand reduction values assumed by the CSP, depending on whether observed or normalized results are considered. We also analyzed sub-station level data and found that the observed load reductions during the test periods were significantly lower than expected, although confounding influences and operational problems significantly limit our ability to differentiate between control-related and non-control related differences in substation-level load shape data. The usefulness and accuracy of the results were hampered by operational problems encountered during the measurement period as well as in sufficient number of load research grade interval meters at one cooperative. Given the larger sample size at one electric cooperative and more statistically-robust results, there is some basis to suggest that the Adjusted Diversified Demand Factor (ADDF) values used by the CSP somewhat over-state the actual load reductions. Given the results and limitations of the M&V approach as implemented, we suggest several options for PJM to consider: (1) require load aggregators participating in ISODR programs to utilize formal PURPA-compliant load research samples in their M&V plans, and (2) continue developing lower cost M&V approaches for mass market load control programs that incorporate suggested improvements described in this study.

Heffner, G.; Moezzi, M.; Goldman, C.

2004-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Control of the direction and rate of nuclear spin flips in InAs quantum dots using detuned optical pulse trains  

E-Print Network [OSTI]

We find that detuning an optical pulse train from electronic transitions in quantum dots controls the direction of nuclear spin flips. The optical pulse train generates electron spins that precess about an applied magnetic field, with a spin component parallel to the field only for detuned pulses. This component leads to asymmetry in the nuclear spin flips, providing a way to produce a stable and precise value of the nuclear spin polarization. This effect is observed using two-color, time-resolved Faraday rotation and ellipticity.

S. G. Carter; A. Shabaev; Sophia E. Economou; T. A. Kennedy; A. S. Bracker; T. L. Reinecke

2009-01-16T23:59:59.000Z

242

Load research manual. Volume 3. Load research for advanced technologies  

SciTech Connect (OSTI)

This three-volume manual presents technical guidelines for electric utility load research. Special attention is given to issues raised by the load data reporting requirements of the Public Utility Regulatory Policies Act of 1978 and to problems faced by smaller utilities that are initiating load research programs. The manual includes guides to load research literature and glossaries of load research and statistical terms. In Volume 3, special load research procedures are presented for solar, wind, and cogeneration technologies.

None

1980-11-01T23:59:59.000Z

243

Spinning Reserve From Responsive Loads  

SciTech Connect (OSTI)

Responsive load is the most underutilized reliability resource available to the power system today. It is currently not used at all to provide spinning reserve. Historically there were good reasons for this, but recent technological advances in communications and controls have provided new capabilities and eliminated many of the old obstacles. North American Electric Reliability Council (NERC), Federal Energy Regulatory Commission (FERC), Northeast Power Coordinating Council (NPCC), New York State Reliability Council (NYSRC), and New York Independent System Operator (NYISO) rules are beginning to recognize these changes and are starting to encourage responsive load provision of reliability services. The Carrier ComfortChoice responsive thermostats provide an example of these technological advances. This is a technology aimed at reducing summer peak demand through central control of residential and small commercial air-conditioning loads. It is being utilized by Long Island Power Authority (LIPA), Consolidated Edison (ConEd), Southern California Edison (SCE), and San Diego Gas and Electric (SDG&E). The technology is capable of delivering even greater response in the faster spinning reserve time frame (while still providing peak reduction). Analysis of demand reduction testing results from LIPA during the summer of 2002 provides evidence to back up this claim. It also demonstrates that loads are different from generators and that the conventional wisdom, which advocates for starting with large loads as better ancillary service providers, is flawed. The tempting approach of incrementally adapting ancillary service requirements, which were established when generators were the only available resources, will not work. While it is easier for most generators to provide replacement power and non-spinning reserve (the slower response services) than it is to supply spinning reserve (the fastest service), the opposite is true for many loads. Also, there is more financial reward for supplying spinning reserve than for supplying the other reserve services as a result of the higher spinning reserve prices. The LIPAedge program (LIPA's demand reduction program using Carrier ComfortChoice thermostats) provides an opportunity to test the use of responsive load for spinning reserve. With potentially 75 MW of spinning reserve capability already installed, this test program can also make an important contribution to the capacity needs of Long Island during the summer of 2003. Testing could also be done at ConEd ({approx}30 MW), SCE ({approx}15 MW), and/or SDG&E ({approx}15 MW). This paper is divided into six chapters. Chapter 2 discusses the contingency reserve ancillary services, their functions in supporting power system reliability, and their technical requirements. It also discusses the policy and tariff requirements and attempts to distinguish between ones that are genuinely necessary and ones that are artifacts of the technologies that were historically used to provide the services. Chapter 3 discusses how responsive load could provide contingency reserves (especially spinning reserve) for the power system. Chapter 4 specifically discusses the Carrier ComfortChoice responsive thermostat technology, the LIPAedge experience with that technology, and how the technology could be used to supply spinning reserve. Chapter 5 discusses a number of unresolved issues and suggests areas for further research. Chapter 6 offers conclusions and recommendations.

Kirby, B.J.

2003-04-08T23:59:59.000Z

244

Composite Load Model Evaluation  

SciTech Connect (OSTI)

The WECC load modeling task force has dedicated its effort in the past few years to develop a composite load model that can represent behaviors of different end-user components. The modeling structure of the composite load model is recommended by the WECC load modeling task force. GE Energy has implemented this composite load model with a new function CMPLDW in its power system simulation software package, PSLF. For the last several years, Bonneville Power Administration (BPA) has taken the lead and collaborated with GE Energy to develop the new composite load model. Pacific Northwest National Laboratory (PNNL) and BPA joint force and conducted the evaluation of the CMPLDW and test its parameter settings to make sure that: the model initializes properly, all the parameter settings are functioning, and the simulation results are as expected. The PNNL effort focused on testing the CMPLDW in a 4-bus system. An exhaustive testing on each parameter setting has been performed to guarantee each setting works. This report is a summary of the PNNL testing results and conclusions.

Lu, Ning; Qiao, Hong (Amy)

2007-09-30T23:59:59.000Z

245

VEHICLE TRACKING USING MOBILE WIRELESS SENSOR NETWORKS DURING DYNAMIC LOAD  

E-Print Network [OSTI]

and put into service, engineers lack cost-effective methods for measuring the actual loads imposedVEHICLE TRACKING USING MOBILE WIRELESS SENSOR NETWORKS DURING DYNAMIC LOAD TESTING OF HIGHWAY in the understanding of vehicle-bridge interactions. Direct measurement of the complex coupling that naturally exists

Lynch, Jerome P.

246

Load attenuating passively adaptive wind turbine blade  

DOE Patents [OSTI]

A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.

Veers, Paul S. (Albuquerque, NM); Lobitz, Donald W. (Albuquerque, NM)

2003-01-01T23:59:59.000Z

247

Load attenuating passively adaptive wind turbine blade  

DOE Patents [OSTI]

A method and apparatus for improving wind turbine performance by alleviating loads and controlling the rotor. The invention employs the use of a passively adaptive blade that senses the wind velocity or rotational speed, and accordingly modifies its aerodynamic configuration. The invention exploits the load mitigation prospects of a blade that twists toward feather as it bends. The invention includes passively adaptive wind turbine rotors or blades with currently preferred power control features. The apparatus is a composite fiber horizontal axis wind-turbine blade, in which a substantial majority of fibers in the blade skin are inclined at angles of between 15 and 30 degrees to the axis of the blade, to produces passive adaptive aeroelastic tailoring (bend-twist coupling) to alleviate loading without unduly jeopardizing performance.

Veers, Paul S.; Lobitz, Donald W.

2003-01-07T23:59:59.000Z

248

Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings  

E-Print Network [OSTI]

a-vis the impact of partial loads on power system componentto test the effect of partial load conditions and possibleto direct-DC savings. Partial load effects reduce estimates

Garbesi, Karina

2012-01-01T23:59:59.000Z

249

Load Response Fundamentally Matches Power System Reliability Requirements  

SciTech Connect (OSTI)

Responsive load is the most underutilized reliability resource available to the power system. Loads are frequently barred from providing the highest value and most critical reliability services; regulation and spinning reserve. Advances in communications and control technology now make it possible for some loads to provide both of these services. The limited storage incorporated in some loads better matches their response capabilities to the fast reliability-service markets than to the hourly energy markets. Responsive loads are frequently significantly faster and more accurate than generators, increasing power system reliability. Incorporating fast load response into microgrids further extends the reliability response capabilities that can be offered to the interconnected power system. The paper discusses the desired reliability responses, why this matches some loads' capabilities, what the advantages are for the power system, implications for communications and monitoring requirements, and how this resource can be exploited.

Kirby, Brendan J [ORNL] [ORNL

2007-01-01T23:59:59.000Z

250

Electric Drive Vehicle Climate Control Load Reduction  

Broader source: Energy.gov [DOE]

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

251

Low reflectance radio frequency load  

DOE Patents [OSTI]

A load for traveling microwave energy has an absorptive volume defined by cylindrical body enclosed by a first end cap and a second end cap. The first end cap has an aperture for the passage of an input waveguide with a rotating part that is coupled to a reflective mirror. The inner surfaces of the absorptive volume consist of a resistive material or are coated with a coating which absorbs a fraction of incident RF energy, and the remainder of the RF energy reflects. The angle of the reflector and end caps is selected such that reflected RF energy dissipates an increasing percentage of the remaining RF energy at each reflection, and the reflected RF energy which returns to the rotating mirror is directed to the back surface of the rotating reflector, and is not coupled to the input waveguide. Additionally, the reflector may have a surface which generates a more uniform power distribution function axially and laterally, to increase the power handling capability of the RF load. The input waveguide may be corrugated for HE11 mode input energy.

Ives, R. Lawrence; Mizuhara, Yosuke M

2014-04-01T23:59:59.000Z

252

Directed Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Directed Energy The Directed Energy Program provides laser systems design, engineering and production for specific applications and missions, experimentally validated...

253

Load Management Made Simple  

E-Print Network [OSTI]

Company have moved to a demand side or load management mode which seeks to influence customers to change electric usage patterns to more efficiently use available generating capacity. Since 1970, the TUEC system peak demand has more than doubled from about...

Schneider, K.

1985-01-01T23:59:59.000Z

254

Cooling load estimation methods  

SciTech Connect (OSTI)

Ongoing research on quantifying the cooling loads in residential buildings, particularly buildings with passive solar heating systems, is described. Correlations are described that permit auxiliary cooling estimates from monthly average insolation and weather data. The objective of the research is to develop a simple analysis method, useful early in design, to estimate the annual cooling energy required of a given building.

McFarland, R.D.

1984-01-01T23:59:59.000Z

255

Control system for a wound-rotor motor  

DOE Patents [OSTI]

A load switching circuit for switching two or more transformer taps under load carrying conditions includes first and second parallel connected bridge rectifier circuits which control the selective connection of a direct current load to taps of a transformer. The first bridge circuit is normally conducting so that the load is connected to a first tap through the first bridge circuit. To transfer the load to the second tap, a switch is operable to connect the second bridge circuit to a second tap, and when the second bridge circuit begins to conduct, the first bridge circuit ceases conduction because the potential at the second tap is higher than the potential at the first tap, and the load is thus connected to the second tap through the second bridge circuit. The load switching circuit is applicable in a motor speed controller for a wound-rotor motor for effecting tap switching as a function of motor speed while providing a stepless motor speed control characteristic.

Ellis, James N. (Chatsworth, CA)

1983-01-01T23:59:59.000Z

256

Mean and peak wind load reduction on heliostats  

SciTech Connect (OSTI)

This report presents the results of wind-tunnel tests supported through the Solar Energy Research Institute (SERI) by the Office of Solar Thermal Technology of the US Department of Energy as part of the SERI research effort on innovative concentrators. As gravity loads on drive mechanisms are reduced through stretched-membrane technology, the wind-load contribution of the required drive capacity increases in percentage. Reduction of wind loads can provide economy in support structure and heliostat drive. Wind-tunnel tests have been directed at finding methods to reduce wind loads on heliostats. The tests investigated both mean and peak forces, and moments. A significant increase in ability to predict heliostat wind loads and their reduction within a heliostat field was achieved. In addition, a preliminary review of wind loads on parabolic dish collectors was conducted, resulting in a recommended research program for these type collectors. 42 refs., 38 figs., 1 tab.

Peterka, J.A.; Tan, L.; Bienkiewcz, B.; Cermak, J.E.

1987-09-01T23:59:59.000Z

257

Measuring Cognitive Load in Multimedia Instruction: A Comparison of Two Instruments  

E-Print Network [OSTI]

is that cognitive load which is not necessary for learning, and is under the control of the designer. Factors determining extraneous load include presentation format and use of graphics or animations (Paas et al., 2003

258

Regression Models for Demand Reduction based on Cluster Analysis of Load Profiles  

E-Print Network [OSTI]

Automated Demand Response in a Large Office Building, CECBuilding Control Strategies and Techniques for Demand Response,Demand Response Load Impacts: Evaluation of Baseline Load Models for Non-Residential Buildings

Kiliccote, Sila

2010-01-01T23:59:59.000Z

259

REVIEW OF METHODS TO REDUCE URBAN STORMWATER LOADS  

E-Print Network [OSTI]

, the implementation of Best Management Practices (BMPs) capable of controlling or removing Hg and PCBs from urban for preliminary prioritization of best management practices (BMPs) (Section 5). Section 3: Describes areas and storm water, measurements of loads in stormwater, and demonstration that either loads

260

Power load forecasting Organization: Huizhou Electric Power, P. R. China  

E-Print Network [OSTI]

Power load forecasting Organization: Huizhou Electric Power, P. R. China Presenter: Zhifeng Hao can be divided into load forecasting and electrical consumption predicting according to forecasting in generators macroeconomic control, power exchange plan and so on. And the prediction is from one day to seven

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

actinides loading optimization: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

actinides loading optimization First Page Previous Page 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Building load control...

262

Taking a Bite out of Lighting Loads  

E-Print Network [OSTI]

Take a Bite Out of Lighting Loads With LEDs Stephen Williams Toshiba Sales Support Manager ESL-KT-13-12-34 CATEE 2013: Clean Air Through Energy Efficiency Conference, San Antonio, Texas Dec. 16-18 Some LED Advantages Less electricity ? 18w LED... = 100w PAR38 No maintenance for years ? 50,000 LED vs.10,000 CFL Improved light quality ? 80 CRI LED vs. 25 CRI HPS Reduce HVAC cooling load Advanced control options ESL-KT-13-12-34 CATEE 2013: Clean Air Through Energy Efficiency Conference, San...

Williams, S.

2013-01-01T23:59:59.000Z

263

CONTRIBUTED Adaptive Stochastic Control  

E-Print Network [OSTI]

stochastic control (ASC) for the Smart Grid holds the promise of providing the autonomous intelligence); approximate dynamic programming (ADP); control systems; Smart Grid I. INTRODUCTION Autonomous control systems pricing, curtailable loads, electric vehicle recharging, solar, wind, and other distributed generation

Powell, Warren B.

264

Short-Term Load Forecasting This paper discusses the state of the art in short-term load fore-  

E-Print Network [OSTI]

spectrum of time intervals. In therange of seconds, when load variationsare small and random, the automatic by a number of generation control functions such as hydro scheduling, unit commitment, hydro-ther- mal present, functions such as fuel, hydro, and maintenance scheduling are performed to ensure that the load

Gross, George

265

Preconditioning Outside Air: Cooling Loads from Building Ventilation  

E-Print Network [OSTI]

of the standard. To mitigate or nullify these additional weather loads, outdoor air preconditioning technologies are being promoted in combination with conventional HVAC operations downstream as a means to deliver the required fresh air and control humidity...

Kosar, D.

1998-01-01T23:59:59.000Z

266

High load operation in a homogeneous charge compression ignition engine  

DOE Patents [OSTI]

A homogeneous charge compression ignition engine is set up by first identifying combinations of compression ratio and exhaust gas percentages for each speed and load across the engines operating range. These identified ratios and exhaust gas percentages can then be converted into geometric compression ratio controller settings and exhaust gas recirculation rate controller settings that are mapped against speed and load, and made available to the electronic

Duffy, Kevin P. (Metamora, IL); Kieser, Andrew J. (Morton, IL); Liechty, Michael P. (Chillicothe, IL); Hardy, William L. (Peoria, IL); Rodman, Anthony (Chillicothe, IL); Hergart, Carl-Anders (Peoria, IL)

2008-12-23T23:59:59.000Z

267

Improvement of load-following capacity based on the flame radiation intensity signal in a power plant  

SciTech Connect (OSTI)

The capability to perform fast load changes has been an important issue due to the increasing commercialization of the power market. In the traditional boiler control system, the feedback signals come from the variations of the steam pressure and the steam flow, which leads to a large time delay. Therefore, a new method for the boiler control system based on radiation intensity for improving the load-following capacity of a coal-fired power plant has been developed in this paper. The system is implemented by adding the radiation intensity of the flame to the existing boiler control system as a complement. The radiation intensity obtained by the sensor can directly reflect the input heat in the boiler, with a faster response and higher sensitivity. Field tests on a 300 MW coal-fired power plant reveal that the improved boiler control system increases the load-following capacity. At the same time, the steam pressure variations are smaller as compared with those of the existing control system. 14 refs., 19 figs., 1 tab.

Fei Wang; Qunxing Huang; Dong Liu; Jianhua Yan; Kefa Cen [Zhejiang University, Hangzhou (China). State Key Laboratory of Clean Energy Utilization

2008-05-15T23:59:59.000Z

268

Loading and pre-loading processes generate a distinct siRNA population in Tetrahymena  

SciTech Connect (OSTI)

Highlights: The Tetrahymena Argonaute protein Twi1p binds to ?2830-nt siRNAs called scnRNAs. The size of scnRNAs is determined during a pre-loading process. The 5? uracil bias of scnRNAs is attributed to pre-loading and loading processes. The thermodynamic asymmetry of scnRNA duplex doesnot affect the guide strand decision. scnRNAs may be produced non-sequentially from dsRNA substrates by Dicer. -- Abstract: The various properties of small RNAs, such as length, terminal nucleotide, thermodynamic asymmetry and duplex mismatches, can impact their sorting into different Argonaute proteins in diverse eukaryotes. The developmentally regulated 26- to 32-nt siRNAs (scnRNAs) are loaded to the Argonaute protein Twi1p and display a strong bias for uracil at the 5? end. In this study, we used deep sequencing to analyze loaded and unloaded populations of scnRNAs. We show that the size of the scnRNA is determined during a pre-loading process, whereas their 5? uracil bias is attributed to both pre-loading and loading processes. We also demonstrate that scnRNAs have a strong bias for adenine at the third base from the 3? terminus, suggesting that most scnRNAs are direct Dicer products. Furthermore, we show that the thermodynamic asymmetry of the scnRNA duplex does not affect the guide and passenger strand decision. Finally, we show that scnRNAs frequently have templated uracil at the last base without a strong bias for adenine at the second base indicating non-sequential production of scnRNAs from substrates. These findings provide a biochemical basis for the varying attributes of scnRNAs, which should help improve our understanding of the production and turnover of scnRNAs in vivo.

Mochizuki, Kazufumi, E-mail: kazufumi.mochizuki@imba.oeaw.ac.at; Kurth, Henriette M.

2013-07-05T23:59:59.000Z

269

2006 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The Pacific Northwest Loads and Resources Study (White Book), which is published annually by the Bonneville Power Administration (BPA), establishes one of the planning bases for supplying electricity to customers. The White Book contains projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. The White Book also contains information obtained from formalized resource planning reports and data submittals including those from individual utilities, the Northwest Power and Conservation Council (Council), and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for determining BPA revenues, although the database that generates the data for the White Book analysis contributes to the development of BPA's inventory and ratemaking processes. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions that include expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. The load resource balance of both the Federal system and the region is determined by comparing resource availability to an expected level of total retail electricity consumption. Resources include projected energy capability plus contract purchases. Loads include a forecast of retail obligations plus contract obligations. Surplus energy is available when resources are greater than loads. This surplus energy could be marketed to increase revenues. Energy deficits occur when resources are less than loads. These energy deficits will be met by any combination of the following: better-than-critical water conditions, demand-side management and conservation programs, permanent loss of loads due to economic conditions or closures, additional contract purchases, and/or the addition of new generating resources. This study incorporates information on Pacific Northwest (PNW) regional retail loads, contract obligations, and contract resources. This loads and resources analysis simulates the operation of the power system in the PNW. The simulated hydro operation incorporates plant characteristics, streamflows, and non-power requirements from the current Pacific Northwest Coordination Agreement (PNCA). Additional resource capability estimates were provided by BPA, PNW Federal agency, public agency, cooperative, U.S. Bureau of Reclamation (USBR), and investor-owned utility (IOU) customers furnished through annual PNUCC data submittals for 2005 and/or direct submittals to BPA. The 2006 White Book is presented in two documents: (1) this summary document of Federal system and PNW region loads and resources, and (2) a technical appendix which presents regional loads, grouped by major PNW utility categories, and detailed contract and resource information. The technical appendix is available only in electronic form. Individual customer information for marketer contracts is not detailed due to confidentiality agreements. The 2006 White Book analysis updates the 2004 White Book. This analysis shows projections of the Federal system and region's yearly average annual energy consumption and resource availability for the study period, OY 2007-2016. The study also presents projections of Federal system and region expected 1-hour monthly peak demand, monthly energy demand, monthly 1-hour peak generating capability, and monthly energy generation for OY 2007, 2011, and 2016. BPA is investigating a new approach in capacity planning depicting the monthly Federal system 120-hour peak generating capability and 120-hour peak surplus/deficit for OY 2007, 2011, and 2016. This document analyzes the PNW's projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency;

United States. Bonneville Power Administration.

2006-03-01T23:59:59.000Z

270

E-Print Network 3.0 - axially loaded magnetic Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

magnetic Search Powered by Explorit Topic List Advanced Search Sample search results for: axially loaded magnetic Page: << < 1 2 3 4 5 > >> 1 Wireless Control of Magnetic Helical...

271

SLUDGE TREATMENT PROJECT COST COMPARISON BETWEEN HYDRAULIC LOADING AND SMALL CANISTER LOADING CONCEPTS  

SciTech Connect (OSTI)

The Sludge Treatment Project (STP) is considering two different concepts for the retrieval, loading, transport and interim storage of the K Basin sludge. The two design concepts under consideration are: (1) Hydraulic Loading Concept - In the hydraulic loading concept, the sludge is retrieved from the Engineered Containers directly into the Sludge Transport and Storage Container (STSC) while located in the STS cask in the modified KW Basin Annex. The sludge is loaded via a series of transfer, settle, decant, and filtration return steps until the STSC sludge transportation limits are met. The STSC is then transported to T Plant and placed in storage arrays in the T Plant canyon cells for interim storage. (2) Small Canister Concept - In the small canister concept, the sludge is transferred from the Engineered Containers (ECs) into a settling vessel. After settling and decanting, the sludge is loaded underwater into small canisters. The small canisters are then transferred to the existing Fuel Transport System (FTS) where they are loaded underwater into the FTS Shielded Transfer Cask (STC). The STC is raised from the basin and placed into the Cask Transfer Overpack (CTO), loaded onto the trailer in the KW Basin Annex for transport to T Plant. At T Plant, the CTO is removed from the transport trailer and placed on the canyon deck. The CTO and STC are opened and the small canisters are removed using the canyon crane and placed into an STSC. The STSC is closed, and placed in storage arrays in the T Plant canyon cells for interim storage. The purpose of the cost estimate is to provide a comparison of the two concepts described.

GEUTHER J; CONRAD EA; RHOADARMER D

2009-08-24T23:59:59.000Z

272

Deterministic Josephson Vortex Ratchet with a load  

E-Print Network [OSTI]

We investigate experimentally a deterministic underdamped Josephson vortex ratchet -- a fluxon-particle moving along a Josephson junction in an asymmetric periodic potential. By applying a sinusoidal driving current one can compel the vortex to move in a certain direction, producing average dc voltage across the junction. Being in such a rectification regime we also load the ratchet, i.e., apply an additional dc bias current I_dc (counterforce) which tilts the potential so that the fluxon climbs uphill due to the ratchet effect. The value of the bias current at which the fluxon stops climbing up defines the strength of the ratchet effect and is determined experimentally. This allows us to estimate the loading capability of the ratchet, the output power and efficiency. For the quasi-static regime we present a simple model which delivers simple analytic expressions for the above mentioned figures of merit.

M. Knufinke; K. Ilin; M. Siegel; D. Koelle; R. Kleiner; E. Goldobin

2011-09-29T23:59:59.000Z

273

Direct write with microelectronic circuit fabrication  

DOE Patents [OSTI]

In a process for deposition of material onto a substrate, for example, the deposition of metals for dielectrics onto a semiconductor laser, the material is deposited by providing a colloidal suspension of the material and directly writing the suspension onto the substrate surface by ink jet printing techniques. This procedure minimizes the handling requirements of the substrate during the deposition process and also minimizes the exchange of energy between the material to be deposited and the substrate at the interface. The deposited material is then resolved into a desired pattern, preferably by subjecting the deposit to a laser annealing step. The laser annealing step provides high resolution of the resultant pattern while minimizing the overall thermal load of the substrate and permitting precise control of interface chemistry and interdiffusion between the substrate and the deposit. 3 figs.

Drummond, T.; Ginley, D.

1988-05-31T23:59:59.000Z

274

Load Expansion of Stoichiometric HCCI Using Spark Assist and Hydraulic Valve Actuation  

SciTech Connect (OSTI)

A spark-assist homogeneous charge compression ignition (SA-HCCI) operating strategy is presented here that allows for stoichiometric combustion from 1000-3000 rpm, and at loads as high as 750 kPa net IMEP. A single cylinder gasoline engine equipped with direct fuel injection and fully variable hydraulic valve actuation (HVA) is used for this experimental study. The HVA system enables negative valve overlap (NVO) valve timing for hot internal EGR. Spark-assist stabilizes combustion over a wide range of engine speeds and loads, and allows for stoichiometric operation at all conditions. Characteristics of both spark-ignited combustion and HCCI are present, with combustion analysis showing a distinctive spark ignited phase of combustion, followed by a much more rapid HCCI combustion phase. At high load, the maximum pressure rise rate is controlled by a combination of spark timing and retarding the intake valve closing angle. The latter reduces the effective compression ratio, and therefore the compressive temperatures, allowing the high load limit of the operating range to be expanded. The SA-HCCI operating strategy exhibits improved thermal efficiency at most operating conditions, with fuel consumption improvements up to 9% realized at light engine loads. The SA-HCCI operating strategy presented here does not provide an efficiency advantage at all operating points compared to SI combustion; a decrease was observed at the highest speed and at loads above 500 kPa net IMEP. At light engine loads the majority of the heat release takes place during the HCCI phase of the heat release, and as such the NOx emissions are very low and are similar to levels observed in pure HCCI. At higher loads, a larger portion of the heat release takes place during the spark ignited phase of combustion, which produces NOx emissions that are much higher than is typically associated with HCCI, but still represent a decrease from conventional SI combustion. By limiting the fuel/air mixture to stoichiometric conditions, the higher NOx emissions do not represent an implementation barrier to this strategy because compatibility is maintained with very effective conventional 3-way catalysts.

Szybist, James P [ORNL; Nafziger, Eric J [ORNL

2010-01-01T23:59:59.000Z

275

Online Load Balancing for Related Machines  

E-Print Network [OSTI]

of entire schedule s as follows: load(s; i) = 1 v i X s(j)=i p j ; Load(s) = max i load(s; i) It is easyOn­line Load Balancing for Related Machines Piotr Berman \\Lambda Moses Charikar y Marek Karpinski z­line load balancing was studied extensively over the years (cf., e.g., [7], [3], [4], and [2

Karpinski, Marek

276

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

componentssuchaspowersources,loads, transformersandcomponentssuchaspowersources,loads, transformersand

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

277

Real power regulation for the utility power grid via responsive loads  

DOE Patents [OSTI]

A system for dynamically managing an electrical power system that determines measures of performance and control criteria for the electric power system, collects at least one automatic generation control (AGC) input parameter to at least one AGC module and at least one automatic load control (ALC) input parameter to at least one ALC module, calculates AGC control signals and loads as resources (LAR) control signals in response to said measures of performance and control criteria, propagates AGC control signals to power generating units in response to control logic in AGC modules, and propagates LAR control signals to at least one LAR in response to control logic in ALC modules.

McIntyre, Timothy J [Knoxville, TN; Kirby, Brendan J [Knoxville, TN; Kisner, Roger A

2009-05-19T23:59:59.000Z

278

MEASUREMENT OF WASTE LOADING IN SALTSTONE  

SciTech Connect (OSTI)

One of the goals of the Saltstone variability study is to identify the operational and compositional variables that control or influence the important processing and performance properties of Saltstone grout mixtures. One of those properties of importance is the Waste Loading (WL) of the decontaminated salt solution (DSS) in the Saltstone waste form. Waste loading is a measure of the amount of waste that can be incorporated within a waste form. The value of the Saltstone waste loading ultimately determines the number of vaults that will be required to disposition all of the DSS. In this report, the waste loading is defined as the volume in milliliters of DSS per liter of Saltstone waste form. The two most important parameters that determine waste loading for Saltstone are water to cementitious material (w/cm) ratio and the cured grout density. Data are provided that show the dependence of waste loading on the w/cm ratio for a fixed DSS composition using the current premix material (45% Blast Furnace Slag (BFS), 45% Fly Ash (FA) and 10% Ordinary Portland Cement (OPC)). The impact of cured grout density on waste loading was also demonstrated. Mixes (at 0.60 w/cm) made with a Modular Caustic side extraction Unit (MCU) simulant and either OPC or BFS have higher cured grout densities than mixes made with premix and increase the WL to 709 mL/L for the OPC mix and 689 mL/L for the BFS mix versus the value of 653 mL/L for MCU in premix at 0.60 w/cm ratio. Bleed liquid reduces the waste loading and lowers the effective w/cm ratio of Saltstone. A method is presented (and will be used in future tasks) for correcting the waste loading and the w/cm ratio of the as-batched mixes in those cases where bleed liquid is present. For example, the Deliquification, Dissolution and Adjustment (DDA) mix at an as-batched 0.60 w/cm ratio, when corrected for % bleed, gives a mix with a 0.55 w/cm ratio and a WL that has been reduced from 662 to 625 mL/L. An example is provided that demonstrated the quantitative impact of WL on the number of cells (each Saltstone vault contains two cells) required to disposition all of the {approx}100 million gallons of DSS available in the tanks. This calculation revealed that the number of cells required over the range of 0.48 to 0.62 w/cm ratio (equivalent to a WL range of 591 to 666 mL/L) varies from 65 to 57 cells (33 to 29 vaults). The intent of this oversimplified example was to show the range of variation in vaults expected due to w/cm ratio rather than to estimate the actual number of vaults required. There is a tradeoff between the waste loading and the processing and performance properties of Saltstone. The performance properties improve in general as the w/cm ratio decreases whereas the waste loading is reduced at lower w/cm ratios resulting in a larger number of Saltstone vaults. The final performance and processing requirements of Saltstone will determine the maximum waste loading achievable.

Harbour, J; Vickie Williams, V

2008-07-18T23:59:59.000Z

279

Dynamic load balancing of applications  

DOE Patents [OSTI]

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated.

Wheat, Stephen R. (Albuquerque, NM)

1997-01-01T23:59:59.000Z

280

Dynamic load balancing of applications  

DOE Patents [OSTI]

An application-level method for dynamically maintaining global load balance on a parallel computer, particularly on massively parallel MIMD computers is disclosed. Global load balancing is achieved by overlapping neighborhoods of processors, where each neighborhood performs local load balancing. The method supports a large class of finite element and finite difference based applications and provides an automatic element management system to which applications are easily integrated. 13 figs.

Wheat, S.R.

1997-05-13T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Recovery Act: Advanced Load Identification and Management for Buildings  

SciTech Connect (OSTI)

In response to the U.S. Department of Energy (DoE)s goal of achieving market ready, net-zero energy residential and commercial buildings by 2020 and 2025, Eaton partnered with the Department of Energys National Renewable Energy Laboratory (NREL) and Georgia Institute of Technology to develop an intelligent load identification and management technology enabled by a novel smart power strip to provide critical intelligence and information to improve the capability and functionality of building load analysis and building power management systems. Buildings account for 41% of the energy consumption in the United States, significantly more than either transportation or industrial. Within the building sector, plug loads account for a significant portion of energy consumption. Plug load consumes 15-20% of building energy on average. As building managers implement aggressive energy conservation measures, the proportion of plug load energy can increase to as much as 50% of building energy leaving plug loads as the largest remaining single source of energy consumption. This project focused on addressing plug-in load control and management to further improve building energy efficiency accomplished through effective load identification. The execution of the project falls into the following three major aspects. 1) An intelligent load modeling, identification and prediction technology was developed to automatically determine the type, energy consumption, power quality, operation status and performance status of plug-in loads, using electric waveforms at a power outlet level. This project demonstrated the effectiveness of the developed technology through a large set of plug-in loads measurements and testing. 2) A novel Smart Power Strip (SPS) / Receptacle prototype was developed to act as a vehicle to demonstrate the feasibility of load identification technology as a low-cost, embedded solution. 3) Market environment for plug-in load control and management solutions, in particular, advanced power strips (APSs) was studied. The project evaluated the market potential for Smart Power Strips (SPSs) with load identification and the likely impact of a load identification feature on APS adoption and effectiveness. The project also identified other success factors required for widespread APS adoption and market acceptance. Even though the developed technology is applicable for both residential and commercial buildings, this project is focused on effective plug-in load control and management for commercial buildings, accomplished through effective load identification. The project has completed Smart Receptacle (SR) prototype development with integration of Load ID, Control/Management, WiFi communication, and Web Service. Twenty SR units were built, tested, and demonstrated in the Eaton lab; eight SR units were tested in the National Renewable Energy Lab (NREL) for one-month of field testing. Load ID algorithm testing for extended load sets was conducted within the Eaton facility and at local university campuses. This report is to summarize the major achievements, activities, and outcomes under the execution of the project.

Yang, Yi; Casey, Patrick; Du, Liang; He, Dawei

2014-02-12T23:59:59.000Z

282

High-Power Rf Load  

DOE Patents [OSTI]

A compact high-power RF load comprises a series of very low Q resonators, or chokes [16], in a circular waveguide [10]. The sequence of chokes absorb the RF power gradually in a short distance while keeping the bandwidth relatively wide. A polarizer [12] at the input end of the load is provided to convert incoming TE.sub.10 mode signals to circularly polarized TE.sub.11 mode signals. Because the load operates in the circularly polarized mode, the energy is uniformly and efficiently absorbed and the load is more compact than a rectangular load. Using these techniques, a load having a bandwidth of 500 MHz can be produced with an average power dissipation level of 1.5 kW at X-band, and a peak power dissipation of 100 MW. The load can be made from common lossy materials, such as stainless steel, and is less than 15 cm in length. These techniques can also produce loads for use as an alternative to ordinary waveguide loads in small and medium RF accelerators, in radar systems, and in other microwave applications. The design is easily scalable to other RF frequencies and adaptable to the use of other lossy materials.

Tantawi, Sami G. (San Mateo, CA); Vlieks, Arnold E. (Livermore, CA)

1998-09-01T23:59:59.000Z

283

Ris-R-Report Load Consequences when Sweeping Blades -  

E-Print Network [OSTI]

reference wind turbine model is used to investigate the influence of different blade sweep curves studies regarding swept wind turbine blades for pitch controlled turbines have indicated that a flapRis-R-Report Load Consequences when Sweeping Blades - A Case Study of a 5 MW Pitch Controlled Wind

284

Directives System  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Department of Energy (DOE) Directives System is the means by which DOE policies, requirements, and responsibilities are developed and communicated throughout the Department. Directives are used to inform, direct, and guide employees in the performance of their jobs, and to enable employees to work effectively within the Department and with agencies, contractors, and the public. Cancels: DOE O 251.1, DOE M 251.1-1

1998-01-30T23:59:59.000Z

285

Spring loaded locator pin assembly  

DOE Patents [OSTI]

This invention deals with spring loaded locator pins. Locator pins are sometimes referred to as captured pins. This is a mechanism which locks two items together with the pin that is spring loaded so that it drops into a locator hole on the work piece.

Groll, Todd A. (Idaho Falls, ID); White, James P. (Pocatelo, ID)

1998-01-01T23:59:59.000Z

286

Spring loaded locator pin assembly  

DOE Patents [OSTI]

This invention deals with spring loaded locator pins. Locator pins are sometimes referred to as captured pins. This is a mechanism which locks two items together with the pin that is spring loaded so that it drops into a locator hole on the work piece. 5 figs.

Groll, T.A.; White, J.P.

1998-03-03T23:59:59.000Z

287

Load Forecasting of Supermarket Refrigeration  

E-Print Network [OSTI]

energy system. Observed refrigeration load and local ambient temperature from a Danish su- permarket renewable energy, is increasing, therefore a flexible energy system is needed. In the present ThesisLoad Forecasting of Supermarket Refrigeration Lisa Buth Rasmussen Kongens Lyngby 2013 M.Sc.-2013

288

Transportation Electrification Load Development For A Renewable Future Analysis: Preprint  

SciTech Connect (OSTI)

The transition to electricity as a transportation fuel will create a new load for electricity generation. A set of regional hourly load profiles for electrified vehicles was developed for the 2010 to 2050 timeframe. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Market saturation scenarios of 30% and 50% of sales of PEVs consuming on average approx. 6 kWh per day were considered. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across four daily time slices under optimal control from the utility?s perspective. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios.

Markel, T.; Mai, T.; Kintner-Meyer, M.

2010-12-01T23:59:59.000Z

289

Loading and Regeneration Analysis of a Diesel Particulate Filter with a Radio Frequency-Based Sensor  

SciTech Connect (OSTI)

Accurate knowledge of diesel particulate filter (DPF) loading is critical for robust and efficient operation of the combined engine-exhaust aftertreatment system. Furthermore, upcoming on-board diagnostics regulations require on-board technologies to evaluate the status of the DPF. This work describes the application of radio frequency (RF) based sensing techniques to accurately measure DPF soot levels and the spatial distribution of the accumulated material. A 1.9L GM turbo diesel engine and a DPF with an RF-sensor were studied. Direct comparisons between the RF measurement and conventional pressure-based methods were made. Further analysis of the particulate matter loading rates was obtained with a mass-based soot emission measurement instrument (TEOM). Comparison with pressure drop measurements show the RF technique is unaffected by exhaust flow variations and exhibits a high degree of sensitivity to DPF soot loading and good dynamic response. Additional computational and experimental work further illustrates the spatial resolution of the RF measurements. Based on the experimental results, the RF technique shows significant promise for improving DPF control enabling optimization of the combined engine-aftertreatment system for improved fuel economy and extended DPF service life.

Sappok, Alex [Filter Sensing Technologies] [Filter Sensing Technologies; Prikhodko, Vitaly Y [ORNL] [ORNL; Parks, II, James E [ORNL

2010-01-01T23:59:59.000Z

290

-Improved estimates of incident radiation and heat load -751 Journal of Vegetation Science 18: 751-754, 2007  

E-Print Network [OSTI]

as predictors. Heat load was calculated as a 45 degree rotation of the PDIR response surface. Results- Improved estimates of incident radiation and heat load - 751 Journal of Vegetation Science 18 regression (NPMR) improve estimates of potential direct incident radia- tion (PDIR) and heat load based

McCune, Bruce

291

A Direct Stator Current Controller for a Doubly-Fed Induction A. D`oria-Cerezo, M. Bodson, C. Batlle and R. Ortega  

E-Print Network [OSTI]

the synchronous speed. Another advantage is that the power electronic equipment that controls the machine only has-fed induction machine with specific applications to renewable energy (wind farms in particular). The proposed control algorithm offers the advantages of proven stability and remarkable simplicity. In contrast

Batlle, Carles

292

Electrical and Production Load Factors  

E-Print Network [OSTI]

, Texas Abstract Load factors and operating hours of small and medium-sized industrial plants are analyzed to classify shift-work patterns and develop energy conservation diagnostic tools. This paper discusses two types of electric load factors... for each shift classification within major industry groups. The load factor based on billing hours (ELF) increases with operating hours from about 0.4 for a nominal one shift operation, to about 0.7 for around-the-clock operation. On the other hand...

Sen, T.; Heffington, W. M.

293

Directives Help  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

All DOE directives are available through this site. While it may seem overwhelming, given the number of documents, we have provided a number of ways in which you may get to the information you need.

294

Transportation Electrification Load Development For a Renewable Future Analysis  

SciTech Connect (OSTI)

Electrification of the transportation sector offers the opportunity to significantly reduce petroleum consumption. The transportation sector accounts for 70% of US petroleum consumption. The transition to electricity as a transportation fuel will create a new load for electricity generation. In support of a recent US Department of Energy funded activity that analyzed a future generation scenario with high renewable energy technology contributions, a set of regional hourly load profiles for electrified vehicles were developed for the 2010 to 2050 timeframe. These load profiles with their underlying assumptions will be presented in this paper. The transportation electrical energy was determined using regional population forecast data, historical vehicle per capita data, and market penetration growth functions to determine the number of plug-in electric vehicles (PEVs) in each analysis region. Two market saturation scenarios of 30% of sales and 50% of sales of PEVs consuming on average {approx}6 kWh per day were considered. Results were generated for 3109 counties and were consolidated to 134 Power Control Areas (PCA) for the use NREL's's regional generation planning analysis tool ReEDS. PEV aggregate load profiles from previous work were combined with vehicle population data to generate hourly loads on a regional basis. A transition from consumer-controlled charging toward utility-controlled charging was assumed such that by 2050 approximately 45% of the transportation energy demands could be delivered across 4 daily time slices under optimal control from the utility perspective. No other literature has addressed the potential flexibility in energy delivery to electric vehicles in connection with a regional power generation study. This electrified transportation analysis resulted in an estimate for both the flexible load and fixed load shapes on a regional basis that may evolve under two PEV market penetration scenarios. EVS25 Copyright.

Markel, Tony; Mai, Trieu; Kintner-Meyer, Michael CW

2010-09-30T23:59:59.000Z

295

Sandia Wind Turbine Loads Database  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

The Sandia Wind Turbine Loads Database is divided into six files, each corresponding to approximately 16 years of simulation. The files are text files with data in columnar format. The 424MB zipped file containing six data files can be downloaded by the public. The files simulate 10-minute maximum loads for the NREL 5MW wind turbine. The details of the loads simulations can be found in the paper: Decades of Wind Turbine Loads Simulations, M. Barone, J. Paquette, B. Resor, and L. Manuel, AIAA2012-1288 (3.69MB PDF). Note that the site-average wind speed is 10 m/s (class I-B), not the 8.5 m/s reported in the paper.

296

Seismic Loading for FAST: May 2011 - August 2011  

SciTech Connect (OSTI)

As more wind farms are constructed in seismically active regions, earthquake loading increases in prominence for design and analysis of wind turbines. Early investigation of seismic load tended to simplify the rotor and nacelle as a lumped mass on top of the turbine tower. This simplification allowed the use of techniques developed for conventional civil structures, such as buildings, to be easily applied to wind turbines. However, interest is shifting to more detailed models that consider loads for turbine components other than the tower. These improved models offer three key capabilities in consideration of base shaking for turbines: 1) The inclusion of aerodynamics and turbine control; 2) The ability to consider component loads other than just tower loads; and 3) An improved representation of turbine response in higher modes by reducing modeling simplifications. Both experimental and numerical investigations have shown that, especially for large modern turbines, it is important to consider interaction between earthquake input, aerodynamics, and operational loads. These investigations further show that consideration of higher mode activity may be necessary in the analysis of the seismic response of turbines. Since the FAST code is already capable of considering these factors, modifications were developed that allow simulation of base shaking. This approach allows consideration of this additional load source within a framework, the FAST code that is already familiar to many researchers and practitioners.

Asareh, M. A.; Prowell, I.

2012-08-01T23:59:59.000Z

297

A 3D finite-element modelling investigation into optimal survey parameters and direct imaging for marine controlled-source electromagnetic surveys  

E-Print Network [OSTI]

Relatively little is known about marine controlled-source electromagnetic surveys (MCSEM) used to detect hydrocarbon reservoirs. Typical MCSEM require the use of inversion to generate a model of the subsurface. We utilize a 3D finite-element forward...

Lau, Ryan

2007-09-17T23:59:59.000Z

298

Direct from CDC's Environmental  

E-Print Network [OSTI]

Direct from CDC's Environmental Health Services Branch Daneen Farrow Collier, M.S.P.H. Editor's note: NEHA strives to pro vide up-to-date and relevant informa tion on environmental health the Environmental Health Services Branch (EHSB) of the Centers for Disease Control and Pre vention (CDC) in every

299

A parametric study of directional sea modeling  

E-Print Network [OSTI]

examines the effect due to wave loading described by the directional sea spectrum on the response of offshore structures. The use of directional seas in design is expected to provide a better representation of the ocean surface and associated kinematics... as compared to unidirectional theory. This in turn should provide a basis for minimizing the overdesign of offshore structures. Several of the more popular directional wave spreading functions are intro- duced. A parametric study is conducted in order...

Whatley, Christopher Paul

2012-06-07T23:59:59.000Z

300

Cooling load design tool for UFAD systems.  

E-Print Network [OSTI]

Underfloor Air Distribution (UFAD) Design Guide. Atlanta:Load Design Tool for Underfloor Air Distribution Systems. for design cooling loads in underfloor air distribution (

Bauman, Fred; Schiavon, Stefano; Webster, Tom; Lee, Kwang Ho

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Self-aligning biaxial load frame  

DOE Patents [OSTI]

An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed crosshead, and by alignment and linear motion elements of one load assembly relative to the load frame.

Ward, Michael B. (Idaho Falls, ID); Epstein, Jonathan S. (Idaho Falls, ID); Lloyd, W. Randolph (Idaho Falls, ID)

1994-01-01T23:59:59.000Z

302

Self-aligning biaxial load frame  

DOE Patents [OSTI]

An self-aligning biaxial loading apparatus for use in testing the strength of specimens while maintaining a constant specimen centroid during the loading operation. The self-aligning biaxial loading apparatus consists of a load frame and two load assemblies for imparting two independent perpendicular forces upon a test specimen. The constant test specimen centroid is maintained by providing elements for linear motion of the load frame relative to a fixed cross head, and by alignment and linear motion elements of one load assembly relative to the load frame. 3 figures.

Ward, M.B.; Epstein, J.S.; Lloyd, W.R.

1994-01-18T23:59:59.000Z

303

Comparison of Design Loads for Turbines in Wake Torben J. Larsen, Helge Aa. Madsen, Gunner Larsen  

E-Print Network [OSTI]

DWM model Wind turbine wake velocity deficit wake meandering aeroelastic simulations wake added #12;Influence from wind direction: Driving torque #12;Influence from wind direction: Tower bottom tilt the turbine never experiences free flow direction at 3D spacing. · Tower loads increase with increased row

304

Influence of loading rate on axially loaded piles in clay  

E-Print Network [OSTI]

. Coyle (Member) ave u ofs (Member) . Hsrsc (Head of Department) May 1984 ABSTRACT Influence of Loading Rate on Axially Loaded Piles in Clay. (May 1984) Enrique Eduardo Garland Ponce, B. S. , Texas A8M University Chairman of Committee: Dr. Jean... and support during all phases of this study. The author also wishes to acknowledge Drs. Harry M. Coyle and David Dubofski who served as members of the advisory committee. Special notes of gratitude to Dr . Wayne A. Dunlap for his aid in the design...

Garland Ponce, Enrique Eduardo

1984-01-01T23:59:59.000Z

305

Feasibility Studies on Disturbance Feedforward Techniques to Improve Wind Turbine Load Mitigation Performance: January 2009 -- January 2010  

SciTech Connect (OSTI)

This study investigates disturbance feedforward and preview control to better understand the best possible improvement in load mitigation using advanced wind measurement techniques.

Laks, J.H.; Dunne, F.; Pao, L. Y.

2010-12-01T23:59:59.000Z

306

Evolution of the residual stress state in a duplex stainless steel during loading  

SciTech Connect (OSTI)

The evolution of micro- and macrostresses in a duplex stainless steel during loading has been investigated in situ by X-ray diffraction. A 1.5 mm cold-rolled sheet of alloy SAF 2304 solution treated at 1,050 C was studied. Owing to differences in the coefficient of thermal expansion between the two phases, compressive residual microstresses were found in the ferritic phase and balancing tensile microstresses in the austenitic phase. The initial microstresses were almost two times higher in the transverse direction compared to the rolling direction. During loading the microstresses increase in the macroscopic elastic regime but start to decrease slightly with increasing load in the macroscopic plastic regime. For instance, the microstresses along the rolling direction in the austenite increase from 60 MPa, at zero applied load, to 110 MPa, at an applied load of 530 MPa. At the applied load of 620 MPa a decrease of the microstress to 90 MPa was observed. During unloading from the plastic regime the microstresses increase by approximately 35 MPa in the direction of applied load but remain constant in the other directions. The initial stress state influences the stress evolution and even after 2.5% plastic strain the main contribution to the microstresses originates from the initial thermal stresses. Finite element simulations show stress variations within one phase and a strong influence of both the elastic and plastic anisotropy of the individual phases on the simulated stress state.

Johansson, J.; Oden, M.; Zheng, X.H. (Linkoeping Univ. (Sweden). Div. of Engineering Materials)

1999-07-09T23:59:59.000Z

307

44-BWR WASTE PACKAGE LOADING CURVE EVALUATION  

SciTech Connect (OSTI)

The objective of this calculation is to evaluate the required minimum burnup as a function of initial boiling water reactor (BWR) assembly enrichment that would permit loading of spent nuclear fuel into the 44 BWR waste package configuration as provided in Attachment IV. This calculation is an application of the methodology presented in ''Disposal Criticality Analysis Methodology Topical Report'' (YMP 2003). The scope of this calculation covers a range of enrichments from 0 through 5.0 weight percent (wt%) U-235, and a burnup range of 0 through 40 GWd/MTU. This activity supports the validation of the use of burnup credit for commercial spent nuclear fuel applications. The intended use of these results will be in establishing BWR waste package configuration loading specifications. Limitations of this evaluation are as follows: (1) The results are based on burnup credit for actinides and selected fission products as proposed in YMP (2003, Table 3-1) and referred to as the ''Principal Isotopes''. Any change to the isotope listing will have a direct impact on the results of this report. (2) The results of 100 percent of the current BWR projected waste stream being able to be disposed of in the 44-BWR waste package with Ni-Gd Alloy absorber plates is contingent upon the referenced waste stream being sufficiently similar to the waste stream received for disposal. (3) The results are based on 1.5 wt% Gd in the Ni-Gd Alloy material and having no tuff inside the waste package. If the Gd loading is reduced or a process to introduce tuff inside the waste package is defined, then this report would need to be reevaluated based on the alternative materials.

J.M. Scaglione

2004-08-25T23:59:59.000Z

308

ELEMENT C: Management Measures Necessary to Achieve Your Load Reductions,  

E-Print Network [OSTI]

, public education, ordinances, pet waste programs, erosion control plans. Regulatory Tools as Management · Identify new management opportunities · Identify critical areas in watershed where additional measures1 ELEMENT C: Management Measures Necessary to Achieve Your Load Reductions, Along with the Critical

309

Exploiting Home Automation Protocols for Load Monitoring in Smart Buildings  

E-Print Network [OSTI]

to reduce consumption is also impor- tant. Smart buildings use demand-side energy management to self consumption with renewable generation [17]. Demand- side management requires buildings to 1) continuously mon@cs.williams.edu Abstract Monitoring and controlling electrical loads is crucial for demand-side energy management in smart

Massachusetts at Amherst, University of

310

Flow Duration Curve Load Duration Curve  

E-Print Network [OSTI]

#12;Flow Duration Curve Load Duration Curve #12;1. Develop Flow Duration Curve 2. Estimate load given flow and concentration data--select appropriate conversion factors 3. Develop Load Duration Curve 4. Plot observed data with Load Duration Curve #12;What are they? How do you make one? #12;Describes

311

Flow Duration Curve Load Duration Curve  

E-Print Network [OSTI]

Flow Duration Curve Load Duration Curve 1. Develop Flow Duration Curve 2. Estimate load given flow and concentration data--select appropriate conversion factors 3. Develop Load Duration Curve 4. Plot observed data with Load Duration Curve What are they? How do you make one? Describes the percent of time a flow rate

312

Commercial equipment loads: End-Use Load and Consumer Assessment Program (ELCAP)  

SciTech Connect (OSTI)

The Office of Energy Resources of the Bonneville Power Administration is generally responsible for the agency's power and conservation resource planning. As associated responsibility which supports a variety of office functions is the analysis of historical trends in and determinants of energy consumption. The Office of Energy Resources' End-Use Research Section operates a comprehensive data collection program to provide pertinent information to support demand-side planning, load forecasting, and demand-side program development and delivery. Part of this on-going program is known as the End-Use Load and Consumer Assessment Program (ELCAP), an effort designed to collect electricity usage data through direct monitoring of end-use loads in buildings. This program is conducted for Bonneville by the Pacific Northwest Laboratory. This report provides detailed information on electricity consumption of miscellaneous equipment from the commercial portion of ELCAP. Miscellaneous equipment includes all commercial end-uses except heating, ventilating, air conditioning, and central lighting systems. Some examples of end-uses covered in this report are office equipment, computers, task lighting, refrigeration, and food preparation. Electricity consumption estimates, in kilowatt-hours per square food per year, are provided for each end-use by building type. The following types of buildings are covered: office, retail, restaurant, grocery, warehouse, school, university, and hotel/motel. 6 refs., 35 figs., 12 tabs.

Pratt, R.G.; Williamson, M.A.; Richman, E.E.; Miller, N.E.

1990-07-01T23:59:59.000Z

313

Laboratory Directed  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-SeriesFlickrinformationPostdocs space controlAppraisal Process Laboratory

314

A commercial electromechanical actuator (EMA) is to be dynamically tested with predetermined stroke and load  

E-Print Network [OSTI]

aircraft mission duty cycle. A hydraulic press will exert a corresponding load profile onto the EMA-model validation. For this test, a Danaher EMA (EC-5) and an MTS hydraulic press (MTS 458.20 controller) are used. The hydraulic press is commanded to exert a corresponding load profile. Due to the limitation of the selected

Wu, Thomas

315

Online Load Balancing for Related Machines 1 Piotr Berman  

E-Print Network [OSTI]

), the load of a machine i in schedule s and Load(s), the load of entire schedule s as follows: load(s; i) = 1On­line Load Balancing for Related Machines 1 Piotr Berman The Pennsylvania State University of randomized algorithms for this problem. Key Words: on­line algorithm, load balancing, related machines

Charikar, Moses

316

The influence of oscillating electromagnetic fields on membrane structure and function: Synthetic liposome and natural membrane bilayer systems with direct application to the controlled delivery of chemical agents  

SciTech Connect (OSTI)

Investigations have been conducted to determine if an imposed electromagnetic field can influence membrane transport, and ion and drug permeability in both synthetic and natural cell membrane systems. Microwave fields enhance accumulation of sodium in the lymphocyte and induce protein shedding at Tc. Microwaves also trigger membrane permeability of liposome systems under specific field exposure conditions. Sensitivity varies in a defined way in bilayers displaying a membrane structural phase transition temperature, Tc; maximal release was observed at or near Tc. Significantly, liposome systems without a membrane phase transition were also found to experience permeability increases but, in contrast, this response was temperature independent. The above results indicate that field-enhanced drug release occurs in liposome vesicles that possess a Tc as well as non-Tc liposomes. Additional studies extend non-Tc liposome responses to the in vivo case in which microwaves trigger Gentamicin release from a liposome depot'' placed subcutaneously in the rat hind leg. In addition, evidence is provided that cell surface sequestered liposomes can be triggered by microwave fields to release drugs directly into target cells. 24 refs., 6 figs.

Liburdy, R.P.; de Manincor, D.; Fingado, B.

1989-09-01T23:59:59.000Z

317

Integrated Transmission and Distribution Control  

SciTech Connect (OSTI)

Distributed, generation, demand response, distributed storage, smart appliances, electric vehicles and renewable energy resources are expected to play a key part in the transformation of the American power system. Control, coordination and compensation of these smart grid assets are inherently interlinked. Advanced control strategies to warrant large-scale penetration of distributed smart grid assets do not currently exist. While many of the smart grid technologies proposed involve assets being deployed at the distribution level, most of the significant benefits accrue at the transmission level. The development of advanced smart grid simulation tools, such as GridLAB-D, has led to a dramatic improvement in the models of smart grid assets available for design and evaluation of smart grid technology. However, one of the main challenges to quantifying the benefits of smart grid assets at the transmission level is the lack of tools and framework for integrating transmission and distribution technologies into a single simulation environment. Furthermore, given the size and complexity of the distribution system, it is crucial to be able to represent the behavior of distributed smart grid assets using reduced-order controllable models and to analyze their impacts on the bulk power system in terms of stability and reliability. The objectives of the project were to: Develop a simulation environment for integrating transmission and distribution control, Construct reduced-order controllable models for smart grid assets at the distribution level, Design and validate closed-loop control strategies for distributed smart grid assets, and Demonstrate impact of integrating thousands of smart grid assets under closed-loop control demand response strategies on the transmission system. More specifically, GridLAB-D, a distribution system tool, and PowerWorld, a transmission planning tool, are integrated into a single simulation environment. The integrated environment allows the load flow interactions between the bulk power system and end-use loads to be explicitly modeled. Power system interactions are modeled down to time intervals as short as 1-second. Another practical issue is that the size and complexity of typical distribution systems makes direct integration with transmission models computationally intractable. Hence, the focus of the next main task is to develop reduced-order controllable models for some of the smart grid assets. In particular, HVAC units, which are a type of Thermostatically Controlled Loads (TCLs), are considered. The reduced-order modeling approach can be extended to other smart grid assets, like water heaters, PVs and PHEVs. Closed-loop control strategies are designed for a population of HVAC units under realistic conditions. The proposed load controller is fully responsive and achieves the control objective without sacrificing the end-use performance. Finally, using the T&D simulation platform, the benefits to the bulk power system are demonstrated by controlling smart grid assets under different demand response closed-loop control strategies.

Kalsi, Karanjit; Fuller, Jason C.; Tuffner, Francis K.; Lian, Jianming; Zhang, Wei; Marinovici, Laurentiu D.; Fisher, Andrew R.; Chassin, Forrest S.; Hauer, Matthew L.

2013-01-16T23:59:59.000Z

318

Master Control of Multiple Air Compressors  

E-Print Network [OSTI]

A single master air pressure controller for several machines can reduce air pressure variation by having a single set-point for all machines. This master control when coupled to a sequencing control package allows positively loading the combination...

Petzold, M. A.

1983-01-01T23:59:59.000Z

319

Independent review of estimated load reductions for PJM's small customer load response pilot project  

E-Print Network [OSTI]

of Estimated Load Reductions for PJMs Small Customer Loadof Estimated Load Reductions for PJMs Small Customer LoadResponse Pilot Project Prepared for PJM Interconnection, LLC

Heffner, G.; Moezzi, M.; Goldman, C.

2004-01-01T23:59:59.000Z

320

PASSIVE DETECTION OF VEHICLE LOADING  

SciTech Connect (OSTI)

The Digital Imaging and Remote Sensing Laboratory (DIRS) at the Rochester Institute of Technology, along with the Savannah River National Laboratory is investigating passive methods to quantify vehicle loading. The research described in this paper investigates multiple vehicle indicators including brake temperature, tire temperature, engine temperature, acceleration and deceleration rates, engine acoustics, suspension response, tire deformation and vibrational response. Our investigation into these variables includes building and implementing a sensing system for data collection as well as multiple full-scale vehicle tests. The sensing system includes; infrared video cameras, triaxial accelerometers, microphones, video cameras and thermocouples. The full scale testing includes both a medium size dump truck and a tractor-trailer truck on closed courses with loads spanning the full range of the vehicle's capacity. Statistical analysis of the collected data is used to determine the effectiveness of each of the indicators for characterizing the weight of a vehicle. The final sensing system will monitor multiple load indicators and combine the results to achieve a more accurate measurement than any of the indicators could provide alone.

Garrett, A.

2012-01-03T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Comparison of propane and methane performance and emissions in a turbocharged direct injection dual fuel engine  

SciTech Connect (OSTI)

With increasingly restrictive NO x and particulate matter emissions standards, the recent discovery of new natural gas reserves, and the possibility of producing propane efficiently from biomass sources, dual fueling strategies have become more attractive. This paper presents experimental results from dual fuel operation of a four-cylinder turbocharged direct injection (DI) diesel engine with propane or methane (a natural gas surrogate) as the primary fuel and diesel as the ignition source. Experiments were performed with the stock engine control unit at a constant speed of 1800 rpm, and a wide range of brake mean effective pressures (BMEPs) (2.7-11.6 bars) and percent energy substitutions (PESs) of C 3 H 8 and CH 4. Brake thermal efficiencies (BTEs) and emissions (NO x, smoke, total hydrocarbons (THCs), CO, and CO 2) were measured. Maximum PES levels of about 80-95% with CH 4 and 40-92% with C 3 H 8 were achieved. Maximum PES was limited by poor combustion efficiencies and engine misfire at low loads for both C 3 H 8 and CH 4, and the onset of knock above 9 bar BMEP for C 3 H 8. While dual fuel BTEs were lower than straight diesel BTEs at low loads, they approached diesel BTE values at high loads. For dual fuel operation, NO x and smoke reductions (from diesel values) were as high as 66-68% and 97%, respectively, but CO and THC emissions were significantly higher with increasing PES at all engine loads

Gibson, C. M.; Polk, A. C.; Shoemaker, N. T.; Srinivasan, K. K.; Krishnan, S. R.

2011-04-20T23:59:59.000Z

322

Methods and apparatus for reducing peak wind turbine loads  

DOE Patents [OSTI]

A method for reducing peak loads of wind turbines in a changing wind environment includes measuring or estimating an instantaneous wind speed and direction at the wind turbine and determining a yaw error of the wind turbine relative to the measured instantaneous wind direction. The method further includes comparing the yaw error to a yaw error trigger that has different values at different wind speeds and shutting down the wind turbine when the yaw error exceeds the yaw error trigger corresponding to the measured or estimated instantaneous wind speed.

Moroz, Emilian Mieczyslaw

2007-02-13T23:59:59.000Z

323

Estimation of Seismic Load Demand for a Wind Turbine in the Time Domain: Preprint  

SciTech Connect (OSTI)

Turbines installed in seismically active regions such as the Pacific Rim or the Mediterranean must consider loads induced by base shaking from an earthquake. To account for this earthquake risk, current International Electrotechnical Commission (IEC) certification requirements provide a simplified method for calculating seismic loads which is intended to be conservative. Through the addition of capabilities, it is now possible to simulate earthquake loading of a wind turbine in conjunction other load sources such as wind and control system behavior using the FAST code. This paper presents a comparison of three earthquake loading scenarios of the National Renewable Energy Laboratory (NREL) offshore 5-MW baseline wind turbine: idling; continued operation through an earthquake; and an emergency shutdown initiated by an earthquake. Using a set of 22 earthquake records, simulations are conducted for each load case. A summary of the resulting tower moment demand is presented to assess the influence of operational state on the resulting structural demand.

Prowell, I.; Elgamal, A.; Uang, C.; Jonkman, J.

2010-03-01T23:59:59.000Z

324

Helicase Loading at Chromosomal Origins of Replication  

E-Print Network [OSTI]

Loading of the replicative DNA helicase at origins of replication is of central importance in DNA replication. As the first of the replication fork proteins assemble at chromosomal origins of replication, the loaded helicase ...

Bell, Stephen P.

325

Self locking coupling mechanism for engaging and moving a load  

DOE Patents [OSTI]

Coupling mechanism (11) for engaging and lifting a load (12) has a housing (19) with a guide passage (18) for receiving a knob (13) which is secured to the load (12) through a neck (15) of smaller diameter. A hollow ball (23) in the housing (19) has an opening (27) which receives the knob (13) and the ball (23) is then turned to displace the opening (27) from the housing passage (18) and to cause the neck (15) to enter a slot (29) in the ball (23) thereby securing the load (12) to the coupling mechanism (11) as elements (49) of the housing (19) block travel of the neck (15) back into the opening (27) when the ball (23) is turned to the load holding orientation. As engagement of the load (12) and locking of the coupling mechanism are accomplished simultaneously by the same ball (23) motion, operation is simplified and reliability is greatly increased. The ball (23) is preferably turned by a motor (32) through worm gearing (36) and the coupling mechanism (11) may be controlled from a remote location. Among other uses, the coupling mechanism (11) is adaptable to the handling of spent nuclear reactor fuel elements (12).

Wood, Richard L. (Livermore, CA); Casamajor, Alan B. (Pleasanton, CA); Parsons, Richard E. (Orinda, CA)

1982-01-01T23:59:59.000Z

326

Self locking coupling mechanism for engaging and moving a load  

DOE Patents [OSTI]

A coupling mechanism for engaging and lifting a load has a housing with a guide passage for receiving a knob which is secured to the load through a neck of smaller diameter. A hollow ball in the housing has an opening which receives the knob and the ball is then turned to displace the opening from the housing passage and to cause the neck to enter a slot in the ball thereby securing the load to the coupling mechanism as elements of the housing block travel of the neck back into the opening when the ball is turned to the load holding orientation. As engagement of the load and locking of the coupling mechanism are accomplished simultaneously by the same ball motion, operation is simplified and reliability is greatly increased. The ball is preferably turned by a motor through worm gearing and the coupling mechanism may be controlled from a remote location. Among other uses, the coupling mechanism is adaptable to the handling of spent nuclear reactor fuel elements.

Wood, R.L.; Casamajor, A.B.; Parsons, R.E.

1980-09-12T23:59:59.000Z

327

Lithium-loaded liquid scintillators  

DOE Patents [OSTI]

The invention is directed to a liquid scintillating composition containing (i) one or more non-polar organic solvents; (ii) (lithium-6)-containing nanoparticles having a size of up to 10 nm and surface-capped by hydrophobic molecules; and (iii) one or more fluorophores. The invention is also directed to a liquid scintillator containing the above composition.

Dai, Sheng (Knoxville, TN); Kesanli, Banu (Mersin, TR); Neal, John S. (Knoxville, TN)

2012-05-15T23:59:59.000Z

328

Communication Load Reduction for Neural Network Implementations  

E-Print Network [OSTI]

the total amount of communication load, followed by a placement of partitions onto proces- sors 3]. We

Behnke, Sven

329

Plug Load Behavioral Change Demonstration Project  

SciTech Connect (OSTI)

This report documents the methods and results of a plug load study of the Environmental Protection Agency's Region 8 Headquarters in Denver, Colorado, conducted by the National Renewable Energy Laboratory. The study quantified the effect of mechanical and behavioral change approaches on plug load energy reduction and identified effective ways to reduce plug load energy. Load reduction approaches included automated energy management systems and behavioral change strategies.

Metzger, I.; Kandt, A.; VanGeet, O.

2011-08-01T23:59:59.000Z

330

Analysis Methodology for Industrial Load Profiles  

E-Print Network [OSTI]

ANALYSIS METHODOLOGY FOR INDUSTRIAL LOAD PROFILES Thomas W. Reddoch Executive Vice President Eleclrolek Concepts, Inc. Knoxvillc, Tennessee ABSTRACT A methodology is provided for evaluating the impact of various demand-side management... (OSM) options on industrial customers. The basic approach uses customer metered load profile data as a basis for the customer load shape. OSM technologies are represented as load shapes and are used as a basis for altering the customers existing...

Reddoch, T. W.

331

A Novel Approach to Determining Motor Load  

E-Print Network [OSTI]

A NOVEL APPROACH TO DETERMINING MOTOR LOAD by Michael Brown Georgia Tech Research Institute Atlanta, Georgia ABSTRACf Properly sized electric motors are essential if industrial plant efficiency is to be optimized and energy costs... minimized. Because of the difficully in making power measurements on three phase motors, loading is rarely, if ever, checked. A simple indication of motor load can be achieved by measuring operating speed because speed and load are almost linearly...

Brown, M.

332

Investigation of sands subjected to dynamic loading  

E-Print Network [OSTI]

become apparent that dynamic, or sud- denly applied loads, present a different type of problem to the engineer. Wind loads on tall structures, pile driving, nuclear blasts, and many other familiar loading conditions cannot be de- scribed or handled... an earthquake or nuclear blast. Also under this category of loading is the pulse which would be purposely induced to fail the soil structure for the purpose of excavation or pile driving. As part of a broader research project concerned with pile dri- ving...

Reeves, Gary Neil

1967-01-01T23:59:59.000Z

333

Direct Liquid Cooling for Electronic Equipment  

SciTech Connect (OSTI)

This report documents a demonstration of an electronic--equipment cooling system in the engineering prototype development stage that can be applied in data centers. The technology provides cooling by bringing a water--based cooling fluid into direct contact with high--heat--generating electronic components. This direct cooling system improves overall data center energy efficiency in three ways: High--heat--generating electronic components are more efficiently cooled directly using water, capturing a large portion of the total electronic equipment heat generated. This captured heat reduces the load on the less--efficient air--based data center room cooling systems. The combination contributes to the overall savings. The power consumption of the electronic equipment internal fans is significantly reduced when equipped with this cooling system. The temperature of the cooling water supplied to the direct cooling system can be much higher than that commonly provided by facility chilled water loops, and therefore can be produced with lower cooling infrastructure energy consumption and possibly compressor-free cooling. Providing opportunities for heat reuse is an additional benefit of this technology. The cooling system can be controlled to produce high return water temperatures while providing adequate component cooling. The demonstration was conducted in a data center located at Lawrence Berkeley National Laboratory in Berkeley, California. Thirty--eight servers equipped with the liquid cooling system and instrumented for energy measurements were placed in a single rack. Two unmodified servers of the same configuration, located in an adjacent rack, were used to provide a baseline. The demonstration characterized the fraction of heat removed by the direct cooling technology, quantified the energy savings for a number of cooling infrastructure scenarios, and provided information that could be used to investigate heat reuse opportunities. Thermal measurement data were used with data center energy use modeling software to estimate overall site energy use. These estimates show that an overall data center energy savings of approximately 20 percent can be expected if a center is retrofitted as specified in the models used. Increasing the portion of heat captured by this technology is an area suggested for further development.

Coles, Henry; Greenberg, Steve

2014-03-01T23:59:59.000Z

334

Minor Actinides Loading Optimization for Proliferation Resistant Fuel Design - BWR  

SciTech Connect (OSTI)

One approach to address the United States Nuclear Power (NP) 2010 program for the advanced light water reactor (LWR) (Gen-III+) intermediate-term spent fuel disposal need is to reduce spent fuel storage volume while enhancing proliferation resistance. One proposed solution includes increasing burnup of the discharged spent fuel and mixing minor actinide (MA) transuranic nuclides (237Np and 241Am) in the high burnup fuel. Thus, we can reduce the spent fuel volume while increasing the proliferation resistance by increasing the isotopic ratio of 238Pu/Pu. For future advanced nuclear systems, MAs are viewed more as a resource to be recycled, and transmuted to less hazardous and possibly more useful forms, rather than simply disposed of as a waste stream in an expensive repository facility. MAs play a much larger part in the design of advanced systems and fuel cycles, not only as additional sources of useful energy, but also as direct contributors to the reactivity control of the systems into which they are incorporated. A typical boiling water reactor (BWR) fuel unit lattice cell model with UO2 fuel pins will be used to investigate the effectiveness of adding MAs (237Np and/or 241Am) to enhance proliferation resistance and improve fuel cycle performance for the intermediate-term goal of future nuclear energy systems. However, adding MAs will increase plutonium production in the discharged spent fuel. In this work, the Monte-Carlo coupling with ORIGEN-2.2 (MCWO) method was used to optimize the MA loading in the UO2 fuel such that the discharged spent fuel demonstrates enhanced proliferation resistance, while minimizing plutonium production. The axial averaged MA transmutation characteristics at different burnup were compared and their impact on neutronics criticality and the ratio of 238Pu/Pu discussed.

G. S. Chang; Hongbin Zhang

2009-09-01T23:59:59.000Z

335

System and method employing a minimum distance and a load feature database to identify electric load types of different electric loads  

DOE Patents [OSTI]

A method identifies electric load types of a plurality of different electric loads. The method includes providing a load feature database of a plurality of different electric load types, each of the different electric load types including a first load feature vector having at least four different load features; sensing a voltage signal and a current signal for each of the different electric loads; determining a second load feature vector comprising at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the different electric loads; and identifying by a processor one of the different electric load types by determining a minimum distance of the second load feature vector to the first load feature vector of the different electric load types of the load feature database.

Lu, Bin; Yang, Yi; Sharma, Santosh K; Zambare, Prachi; Madane, Mayura A

2014-12-23T23:59:59.000Z

336

Properly Evaluating load-following products  

SciTech Connect (OSTI)

The authors briefly survey the jurisdictions where load-following products have been successfully used, examine the characteristics of the load-following products, and explain the shortcomings and inaccurate conclusions of previous analyses. A more thorough analysis reveals that the load-following products fulfill the public policy objectives for which they have been designed and do not adversely impact wholesale electricity markets.

Cavicchi, Joseph; Lemon, Andrew

2009-01-15T23:59:59.000Z

337

Design of a low-cost worm-gear system as teaching tool for controller design  

E-Print Network [OSTI]

connected with a potentiometer and a set of removable loads. Four controllers, the PID controller, LQR controller, H[] controller and fuzzy logic controller are designed, simulated and implemented. These controllers are designed in the continuous time domain...

Xu, Donghang

2012-06-07T23:59:59.000Z

338

1993 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The Loads and Resources Study is presented in three documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; (2) a technical appendix detailing forecasted Pacific Northwest economic trends and loads, and (3) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. In this loads and resources study, resource availability is compared with a range of forecasted electricity consumption. The forecasted future electricity demands -- firm loads -- are subtracted from the projected capability of existing and {open_quotes}contracted for{close_quotes} resources to determine whether Bonneville Power Administration (BPA) and the region will be surplus or deficit. If resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA can sell to increase revenues. Conversely, if firm loads exceed available resources, there is a deficit of energy and/or capacity, and additional conservation, contract purchases, or generating resources will be needed to meet load growth. The Pacific Northwest Loads and Resources Study analyzes the Pacific Northwest`s projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional power system, which includes loads and resource in addition to the Federal system. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA) produced by the Pacific Northwest Coordinating Group. This study presents the Federal system and regional analyses for five load forecasts: high, medium-high, medium, medium-low, and low. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 1994--95 through 2003--04.

United States. Bonneville Power Administration.

1993-12-01T23:59:59.000Z

339

High loading uranium fuel plate  

DOE Patents [OSTI]

Two embodiments of a high uranium fuel plate are disclosed which contain a meat comprising structured uranium compound confined between a pair of diffusion bonded ductile metal cladding plates uniformly covering the meat, the meat having a uniform high fuel loading comprising a content of uranium compound greater than about 45 Vol. % at a porosity not greater than about 10 Vol. %. In a first embodiment, the meat is a plurality of parallel wires of uranium compound. In a second embodiment, the meat is a dispersion compact containing uranium compound. The fuel plates are fabricated by a hot isostatic pressing process.

Wiencek, Thomas C. (Bolingbrook, IL); Domagala, Robert F. (Indian Head Park, IL); Thresh, Henry R. (Palos Heights, IL)

1990-01-01T23:59:59.000Z

340

Dynamic Load Balancing of Virtualized Database Services Using Hints and Load  

E-Print Network [OSTI]

server during runtime. Figure 1 shows the load curve of a typical interactive service. In the morningDynamic Load Balancing of Virtualized Database Services Using Hints and Load Forecasting Daniel-organizing infrastructures to react proactively. For this pur- pose we present two techniques: Short-term load forecasting

Kemper, Alfons

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

High payload six-axis load sensor  

DOE Patents [OSTI]

A repairable high-payload six-axis load sensor includes a table, a base, and at least three shear-pin load transducers removably mounted between the table and the base. Removable mounting permits easy replacement of damaged shear pins. Preferably, the shear-pin load transducers are responsive to shear forces imparted along the two axes perpendicular to an axis of minimum sensitivity characteristic of the transducer. Responsive to an applied shear force, each shear-pin load transducer can produce an electrical signal proportional to the reaction force. The load sensor can further include a structure for receiving the proportional electrical signals and computing the applied load corresponding to the proportional electrical signals. The computed load can be expressed in terms of a three-dimensional XYZ Cartesian coordinate system.

Jansen, John F. (Knoxville, TN); Lind, Randall F. (Knoxville, TN)

2003-01-01T23:59:59.000Z

342

Spinning Reserve From Hotel Load Response: Initial Progress  

SciTech Connect (OSTI)

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

Kueck, John D [ORNL; Kirby, Brendan J [ORNL

2008-11-01T23:59:59.000Z

343

Directives Help - DOE Directives, Delegations, and Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Directives Help by Website Administrator All DOE directives are available through this site. While it may seem overwhelming, given the number of documents, we have provided a...

344

Plastic instabilities in statically and dynamically loaded spherical vessels  

SciTech Connect (OSTI)

Significant changes were made in design limits for pressurized vessels in the 2007 version of the ASME Code (Section VIII, Div. 3) and 2008 and 2009 Addenda. There is now a local damage-mechanics based strain-exhaustion limit as well as the well-known global plastic collapse limit. Moreover, Code Case 2564 (Section VIII, Div. 3) has recently been approved to address impulsively loaded vessels. It is the purpose of this paper to investigate the plastic collapse limit as it applies to dynamically loaded spherical vessels. Plastic instabilities that could potentially develop in spherical shells under symmetric loading conditions are examined for a variety of plastic constitutive relations. First, a literature survey of both static and dynamic instabilities associated with spherical shells is presented. Then, a general plastic instability condition for spherical shells subjected to displacement controlled and impulsive loading is given. This instability condition is evaluated for six plastic and visco-plastic constitutive relations. The role of strain-rate sensitivity on the instability point is investigated. Calculations for statically and dynamically loaded spherical shells are presented, illustrating the formation of instabilities as well as the role of imperfections. Conclusions of this work are that there are two fundamental types of instabilities associated with failure of spherical shells. In the case of impulsively loaded vessels, where the pulse duration is short compared to the fundamental period of the structure, one instability type is found not to occur in the absence of static internal pressure. Moreover, it is found that the specific role of strain-rate sensitivity on the instability strain depends on the form of the constitutive relation assumed.

Duffey, Thomas A [Los Alamos National Laboratory; Rodriguez, Edward A [Los Alamos National Laboratory

2010-01-01T23:59:59.000Z

345

Commercial and Industrial Conservation and Load Management Programs at New England Electric  

E-Print Network [OSTI]

COMMERCIAL AND INDUSTRIAL CONSERVAT~ON AND LOAD MANAGEMENT PROGRAMS AT NEW ENGLAND ELECTRIC PETER H. GIBSON Manager, Load Management and Conservation Services New England Power Service Company Westborough, Massachusetts ABSTRACT New... is directed mainly toward the commercial and industrial classes, which mske up 62% of sales. The overall program, called Partners In Energy Planning, includes a performance contracting or modified shared savings program, a lighting subsidy program, a...

Gibson, P. H.

346

Oktober 26. 2009 Prediction of Load and Power Fluctuations from Wind Turbine  

E-Print Network [OSTI]

and into the tangential direction of rotation of the wind turbine given by 1 0tan 2 2 0 (1.6) This is because a lidarOktober 26. 2009 Vers 003 Prediction of Load and Power Fluctuations from Wind Turbine Spinner for the fluctuating loads on the blade tip: The lift force on a section of a wind turbine's blade is given by the lift

347

Climate Change Impacts on Residential and Commercial Loads in the Western U.S. Grid  

SciTech Connect (OSTI)

This report presents a multi-disciplinary modeling approach to quickly quantify climate change impacts on energy consumption, peak load, and load composition of residential and commercial buildings. This research focuses on addressing the impact of temperature changes on the building cooling load in 10 major cities across the Western United States and Canada. Our results have shown that by the mid-century, building yearly energy consumption and peak load will increase in the Southwest. Moreover, the peak load months will spread out to not only the summer months but also spring and autumn months. The Pacific Northwest will experience more hot days in the summer months. The penetration of the air conditioning (a/c) system in this area is likely to increase significantly over the years. As a result, some locations in the Pacific Northwest may be shifted from winter peaking to summer peaking. Overall, the Western U.S. grid may see more simultaneous peaks across the North and South in summer months. Increased cooling load will result in a significant increase in the motor load, which consumes more reactive power and requires stronger voltage support from the grid. This study suggests an increasing need for the industry to implement new technology to increase the efficiency of temperature-sensitive loads and apply proper protection and control to prevent possible adverse impacts of a/c motor loads.

Lu, Ning; Taylor, Zachary T.; Jiang, Wei; Xie, YuLong; Leung, Lai R.; Correia, James; Wong, Pak C.; Mackey, Patrick S.; Paget, Maria L.

2008-09-30T23:59:59.000Z

348

Radiological Control - DOE Directives, Delegations, and Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 -the Mid-Infrared at 278, 298, and 323Program AccomplishmentsScience

349

Bulk Modulus Capacitor Load Cells  

SciTech Connect (OSTI)

Measurement of forces present at various locations within the SSC Model Dipole collared coil assembly is of great practical interest to development engineers. Of particular interest are the forces between coils at the parting plane and forces that exist between coils and pole pieces. It is also desired to observe these forces under the various conditions that a magnet will experience such as: during the collaring process, post-collaring, under the influence of cryogens, and during field excitation. A twenty eight thousandths of an inch thick capacitor load cell which utilizes the hydrostatic condition of a stressed plastic dielectric has been designed. These cells are currently being installed on SSC Model Dipoles. The theory, development, and application of these cells will be discussed.

Dickey, C.E.

1990-04-01T23:59:59.000Z

350

High voltage load resistor array  

DOE Patents [OSTI]

A high voltage resistor comprising an array of a plurality of parallel electrically connected resistor elements each containing a resistive solution, attached at each end thereof to an end plate, and about the circumference of each of the end plates, a corona reduction ring. Each of the resistor elements comprises an insulating tube having an electrode inserted into each end thereof and held in position by one or more hose clamps about the outer periphery of the insulating tube. According to a preferred embodiment, the electrode is fabricated from stainless steel and has a mushroom shape at one end, that inserted into the tube, and a flat end for engagement with the end plates that provides connection of the resistor array and with a load.

Lehmann, Monty Ray (Smithfield, VA)

2005-01-18T23:59:59.000Z

351

Loads Providing Ancillary Services: Review of International Experience  

E-Print Network [OSTI]

In PJM for example, loads and generators that can follow theto generators and loads, who can follow operators second bya reflection of the loads inability to follow minute-by-

Heffner, Grayson

2008-01-01T23:59:59.000Z

352

Preliminary Evaluation of Load Management for Electricity End Users  

E-Print Network [OSTI]

The planning, design and implementation of load management is complex and expensive. The results of a load management program are subject to numerous uncertainties related to load characteristics, power cost savings, load management costs...

Collier, S. E.

1984-01-01T23:59:59.000Z

353

Online Load Balancing for Related Machines 1 (Revised Piotr Berman  

E-Print Network [OSTI]

s as follows: load(s; i) = 1 v i X s(j)=i p j ; Load(s) = max i load(s; i) It is easy to observe that findingOn­line Load Balancing for Related Machines 1 (Revised Version) Piotr Berman The Pennsylvania State of randomized algorithms for this problem. Key Words: on­line algorithm, load balancing, related machines

Karpinski, Marek

354

Loads Providing Ancillary Services: Review of International Experience  

E-Print Network [OSTI]

Load Following)Imbalance Management (Load Following) Energy Imbalanceload participation in ancillary service markets, we offer the following

Heffner, Grayson

2008-01-01T23:59:59.000Z

355

Loads Providing Ancillary Services: Review of International Experience  

E-Print Network [OSTI]

for generators. A partial list of load attributes andpartial list includes: Minimum run times Minimum off times Minimum load

Heffner, Grayson

2008-01-01T23:59:59.000Z

356

Commercial Building Loads Providing Ancillary Services in PJM  

SciTech Connect (OSTI)

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

MacDonald, Jason; Kiliccote, Sila; Boch, Jim; Chen, Jonathan; Nawy, Robert

2014-06-27T23:59:59.000Z

357

Loading of a surface electrode ion trap from a remote, pre-cooled source  

E-Print Network [OSTI]

We demonstrate for the first time the loading of ions into a surface electrode trap (SET) from a remote, laser-cooled source of neutral atoms. We first cool and load $\\sim$ $10^6$ neutral $^{88}$Sr atoms into a magneto-optical trap (MOT) from an oven that has no line-of-sight with the SET. The cold atoms are then pushed with a resonant laser into the trap region where they are subsequently photoionized and trapped in an SET operated at a cryogenic temperature of 4.6 K. We present studies of the loading process and show that our technique achieves ion loading into a shallow (15 meV depth) trap at rates as high as 125 ions/s while drastically reducing the amount of deposition of metal on the trap surface as compared with direct loading from a hot vapor. Furthermore, we note that due to multiple stages of isotopic filtering in our loading process, this technique has enhanced isotopic selectivity over other loading methods. Rapid loading from a clean, isotopically pure, and pre-cooled source will potentially enab...

Sage, Jeremy M; Chiaverini, John

2012-01-01T23:59:59.000Z

358

Superconducting VAR control. [Patent application  

DOE Patents [OSTI]

Static VAR control means are described employing an asymmetrically controlled Graetz bridge and a superconducting direct current coil having low losses and low cost characteristics.

Boenig, H.J.; Hassenzahl, W.V.

1980-12-05T23:59:59.000Z

359

Optimal Time-of-Use Pricing For Residential Load Control  

E-Print Network [OSTI]

a novel algorithm for finding an optimum time-of-use electricity pricing in monopoly utility markets implementing a demand response strategy. Finally, the effect of demand response in electricity prices to changes in the price of electricity over time via incentive payments designed to induce lower electricity

Kumar, Sunil

360

Prognostic Control and Load Survivability in Shipboard Power Systems  

E-Print Network [OSTI]

...............................................................................................9? 2.5? Reliability Centered Maintenance ........................................................10? 2.6? Power Distribution System Reliability .................................................13? 2.7? Summary... centered maintenance (RCM), and power distribution system reliability techniques are principles are mentioned as well. In chapter III, the modeling principles of structure functions and survivability are stated. The 3 problem formulation is also...

Thomas, Laurence J.

2011-02-22T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Pore Surface Engineering with Controlled Loadings of Functional Groups via  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert Southwest RegionatSearch Welcome to theNews & Blog »Physics Accounts

362

Pore Surface Engineering with Controlled Loadings of Functional Groups via  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert Southwest RegionatSearch Welcome to theNews & Blog »Physics AccountsClick

363

Optimal control strategies for load carrying drones Alicia Arce  

E-Print Network [OSTI]

drones (that is, unmanned aerial vehicles -UAVs- with the capacity to fly semi- or fully autonomously. The invention of light materials, low energy consumption machines and high performance processing units led to the construction of flexible flying robots. They can be used in a variety of applications such as vehicle tracking

Boyer, Edmond

364

Building Technologies Office Load Control Strategies | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EEREDepartmentFebruaryResistanceBuilding EnergyEnergy 2015

365

Electric Drive Vehicle Climate Control Load Reduction | Department of  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat PumpRecord ofESPC ENABLE: ECM Summary ECMWeartheEfficientlyInc.

366

2012 CERTS LAAR Program Peer Review - Integration and Extension of Direct Load Management of Smart Loads - Anna Scaglioni, UC Davis  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up from theDepartment( SampleEnergyof Environmental Management | Department

367

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

AirConditionerTestinginWECC,IEEEPower EngineeringAirConditionerModeling,WECCLoadModelingTask Forceinpowersystemstudies:WECCprogressupdate,?Powerand

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

368

FINAL PROJECT REPORT LOAD MODELING TRANSMISSION RESEARCH  

E-Print Network [OSTI]

Lights HVAC Figure 15 Demand Response and Market AnalysisHVAC Load % of Total Hour of Day Figure 16 Demand Response and Market

Lesieutre, Bernard

2013-01-01T23:59:59.000Z

369

Decentralized customerlevel under frequency load shedding in...  

Open Energy Info (EERE)

project focuses on a smart demand side management of household consumers. Modern communication technology enables the management of large groups of distributed loads under a...

370

System and method employing a self-organizing map load feature database to identify electric load types of different electric loads  

SciTech Connect (OSTI)

A method identifies electric load types of a plurality of different electric loads. The method includes providing a self-organizing map load feature database of a plurality of different electric load types and a plurality of neurons, each of the load types corresponding to a number of the neurons; employing a weight vector for each of the neurons; sensing a voltage signal and a current signal for each of the loads; determining a load feature vector including at least four different load features from the sensed voltage signal and the sensed current signal for a corresponding one of the loads; and identifying by a processor one of the load types by relating the load feature vector to the neurons of the database by identifying the weight vector of one of the neurons corresponding to the one of the load types that is a minimal distance to the load feature vector.

Lu, Bin; Harley, Ronald G.; Du, Liang; Yang, Yi; Sharma, Santosh K.; Zambare, Prachi; Madane, Mayura A.

2014-06-17T23:59:59.000Z

371

Departmental Directives Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order is the primary directive for administering the Department's directives Program. Cancels: DOE O 251.1A

2006-08-16T23:59:59.000Z

372

Evaluation of the megawatt demand setter for load-follow operation of C-E's SYSTEM 80+  

SciTech Connect (OSTI)

The Megawatt Demand Setter (MDS) is a digital supervisory control system that automatically assures that the turbine load is consistent with plant operating limits for critical parameters. The MDS is designed to avert plant trips by limiting the load demand during load transients and by reducing the turbine load if plant operating limits are approached or violated. The MDS, devised and patented by Combustion Engineering, Inc., in the 1970s for automatic load dispatching, has been installed at two plants. Those plants have since been operated in a base-load capacity, however, and have not needed to implement the load-follow capabilities of the MDS. As the percentage of electricity generated by nuclear units increases, the need to implement such load-follow capabilities will also increase. Combustion Engineering intends to incorporate improved load-follow capability in its SYSTEM 80+ nuclear steam supply system (NSSS) design. One aspect of this will be incorporation of the MDS in the design of the NUPLEX 80+ advanced control complex for system 80+. This paper presents an evaluation of two major design features of the MDS for load-follow operation based on simulation of SYSTEM 80+ plant responses.

Choi, J.I.; Scarola, K.

1989-01-01T23:59:59.000Z

373

Automotive Power Generation and Control  

E-Print Network [OSTI]

This paper describes some new developments in the application of power electronics to automotive power generation and control. A new load-matching technique is introduced that uses a simple switched-mode rectifier to achieve ...

Caliskan, Vahe

374

Pressurized fluidized-bed combustion part-load behavior. Volume I. Summary report  

SciTech Connect (OSTI)

Tests performed during 1980 to determine the part-load characteristics of a pressurized fluidized-bed combustor for a combined-cycle power plant and to examine its behavior during load changing are discussed. Part-load operation was achieved by varying the bed temperature by amounts between 200 to 300/sup 0/F and the bed depth from between 9 and 10 ft at rates varying between 0.2 ft/min and 0.5 ft/min. The performance at part-load steady-state conditions and during transient conditions is reported with information on combustion efficiency (99% at full-load with 9 ft bed depth and 1650/sup 0/F bed temperature; 95% with 4 ft depth and 1390/sup 0/F); sulfur retention (95/sup 0/ at full load to 80% at low bed depth and low bed temperature); sulfur emissions (no definitive results); NO/sub x/ emissions (tendency for increase as bed temperature was reduced); alkali emissions (no bed temperature effect detected); and heat transfer. It was demonstrated that load can be altered in a rapid and controlled manner by changing combinations of bed depth temperature and pressure. The most important practical change was the reduction in O/sub 2/ concentration which occurred when the bed height was increased at a rapid rate. The extra energy required to reheat the incoming bed material resulted (in the most extreme case) in a temporary drop in excess air from 65% to 12%. In a full-scale plant the loss of heat from the stored bed material would be much lower and the excess air trough when increasing load would not be as pronounced. Nevertheless, it seems prudent to design full-scale plant for a full load excess air of not less than about 50% when using bed depth as a load control parameter.

Roberts, A. G.; Pillai, K. K.; Raven, P.; Wood, P.

1981-09-01T23:59:59.000Z

375

IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 20, NO. 2, APRIL 2005 1009 Autonomous Load Sharing of  

E-Print Network [OSTI]

power control can be tuned without interfering with steady-state reactive power sharing. Simulation technique shares a common active load, its reactive power control scheme is plant parameter dependent to synthesize a novel reactive power sharing scheme. Time domain circuit simulation results are presented

Lehn, Peter W.

376

Wind loading on solar collectors  

SciTech Connect (OSTI)

The present design methodology for the determination of wind loading on the various solar collectors has been reviewed and assessed. The total force coefficients of flat plates of aspect ratios 1.0 and 3.0, respectively, at various angles of attack obtained by using the guidelines of the ANSI A58.1-1982, have been compared with those obtained by using the methodology of the ASCE Task Committee, 1961, and the experimental results of the full-scale test of heliostats by Peglow. The turbulent energy spectra, currently employed in the building code, are compared with those of Kaimal et al., Lumley, and Ponofsky for wind velocities of 20.0 m/s and 40.24 m/s at an elevation of 9.15 m. The longitudinal spectra of the building code overestimates the Kaimal spectra in the frequency range of 0.007 Hz to 0.08 Hz and underestimates beyond the frequency of 0.08 Hz. The peak angles of attack, on the heliostat, stowed in horizontal position, due to turbulent vertical and lateral components of wind velocity, have been estimated by using Daniel's methodology for three wind velocities and compared with the value suggested by the code. The experimental results of a simple test in the laboratory indicate the feasibility of decreasing the drag forces of the flat plate by reducing the solidity ratio.

Bhaduri, S.; Murphy, L.M.

1985-06-01T23:59:59.000Z

377

STRUCTURAL RESPONSE OF THE DIII-D TOROIDAL FIELD COIL TO INCREASED LATERAL LOADS  

SciTech Connect (OSTI)

OAK-B135 Recent calibration shots in which full toroidal field (TF) coil current interacted with the maximum poloidal field coils have produced increased lateral loads on the outer sections of the TF-coil. The increased lateral loads have resulted in deflections that have been sufficient to cause the TF-coil to contact adjacent equipment and produce a transient short to ground within the coil. The six outer turns of each TF-coil bundle are clamped together by insulated preloaded studs to provide increased bending stiffness. These sections of the outer bundles depend on friction to react the lateral loads as a bundle rather than six individual turns. A major concern is that the increased loads will produce slip between turns resulting in excessive lateral deflections and possible damage to the insulating sleeve on the preloaded studs. A finite element structural model of the TF-coil was developed for the calculation of deflections and the shear load distribution throughout the coil for the applied lateral loads from a full current calibration shot. The purpose of the updated structural model is to correlate the applied lateral loads to the total shear force between the unbonded sections of the outer turns. An allowable integrated lateral load applied to the outer turns is established based on the maximum shear force that can be reacted by friction. A program that calculates the magnetic fields and integrated lateral load along the outer turns can be incorporated into the plasma control system. The integrated load can then be compared to the calculated allowable value prior to execution of calibration shots. Calibration shots with a calculated total lateral load greater than the allowable value will be prevented.

REIS,E.E; CHIN,E

2003-10-01T23:59:59.000Z

378

Soil load above Hanford waste storage tanks (2 volumes)  

SciTech Connect (OSTI)

This document is a compilation of work performed as part of the Dome Load Control Project in 1994. Section 2 contains the calculations of the weight of the soil over the tank dome for each of the 75-feet-diameter waste-storage tanks located at the Hanford Site. The chosen soil specific weight and soil depth measured at the apex of the dome crown are the same as those used in the primary analysis that qualified the design. Section 3 provides reference dimensions for each of the tank farm sites. The reference dimensions spatially orient the tanks and provide an outer diameter for each tank. Section 4 summarizes the available soil surface elevation data. It also provides examples of the calculations performed to establish the present soil elevation estimates. The survey data and other data sources from which the elevation data has been obtained are printed separately in Volume 2 of this Supporting Document. Section 5 contains tables that provide an overall summary of the present status of dome loads. Tables summarizing the load state corresponding to the soil depth and soil specific weight for the original qualification analysis, the gravity load requalification for soil depth and soil specific weight greater than the expected actual values, and a best estimate condition of soil depth and specific weight are presented for the Double-Shell Tanks. For the Single-Shell Tanks, only the original qualification analysis is available; thus, the tabulated results are for this case only. Section 6 provides a brief overview of past analysis and testing results that given an indication of the load capacity of the waste storage tanks that corresponds to a condition approaching ultimate failure of the tank. 31 refs.

Pianka, E.W. [Advent Engineering Services, Inc., San Ramon, CA (United States)

1995-01-25T23:59:59.000Z

379

Effects of dynamic conditions and sheave efficiency on hook load, derrick load, and line tension  

E-Print Network [OSTI]

EFFECTS OF DYNAMIC CONDITIONS AND SHEAVE EFFICIENCY ON HOOK LOAD, DERRICK LOAD, AND LINE TENSION A Thesis by GREGORY ROBERT LUKE Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements... for the degree of MASTER OF SCIENCE May 1991 Major Subject: Petroleum Engineering EFFECTS OF DYNAMIC CONDITIONS AND SHEAVE EFFICIENCY ON HOOK LOAD, DERRICK LOAD, AND LINE TENSION A Thesis by GREGORY ROBERT LUKE Approved as to style and content by: Hans...

Luke, Gregory Robert

1991-01-01T23:59:59.000Z

380

A Field Study on Residential Air Conditioning Peak Loads During Summer in College Station, Texas  

E-Print Network [OSTI]

compressor use. This is advantageous in that it simplifies the experimental hardware requirements in projects of the sort undertaken here. (b) The base loads, i.e., the minimum electric load due to refrigerator, lights and other equipment which run all... to their customers to various incentives and load control programs, and the use of thermal storage systems (George, 1988). The Bryan Municipal Utility in Bryan, TX has a program which offers a rebate of $200 to any homeowner who installs an AC with a Seasonal Energy...

Reddy, T. A.; Vaidya, S.; Griffith, L.; Bhattacharyya, S.; Claridge, D. E.

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Direct current uninterruptible power supply method and system  

DOE Patents [OSTI]

A method and system are described for providing a direct current (DC) uninterruptible power supply with the method including, for example: continuously supplying fuel to a turbine; converting mechanical power from the turbine into alternating current (AC) electrical power; converting the AC electrical power to DC power within a predetermined voltage level range; supplying the DC power to a load; and maintaining a DC load voltage within the predetermined voltage level range by adjusting the amount of fuel supplied to the turbine.

Sinha, Gautam

2003-12-02T23:59:59.000Z

382

REACTIVE LOAD MODELINGIMPACTS ONNODAL PRICESINPOOL MODELELECTRICITYMARKETS  

E-Print Network [OSTI]

REACTIVE LOAD MODELINGIMPACTS ONNODAL PRICESINPOOL MODELELECTRICITYMARKETS EttoreBompard, Enrico of the nodal prices in competitive electricity markets based on the Pool paradigm. Such prices focus of the paper is on the explicit evaluation of the impactsof the reactive load onthenodal real

Gross, George

383

1997 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The 1997 White Book is presented in two documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; and (2) a technical appendix detailing the loads and resources for each major Pacific Northwest generating utility. Data detailing Pacific Northwest non-utility generating (NUG) resources is also available upon request. This analysis updates the 1996 pacific Northwest Loads and Resources Study, published in December 1996. In this loads and resources study, resource availability is compared with a medium forecast of electricity consumption. This document analyzes the Pacific Northwest`s projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for which BPA is the marketing agency; and (2) the larger Pacific Northwest regional power system which includes loads and resources in addition to the Federal system. This study presents the Federal system and regional analyses for the medium load forecast. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 1998--99 through 2007--08.

United States. Bonneville Power Administration.

1997-12-01T23:59:59.000Z

384

Load Management DSM: Past, Present & Future  

E-Print Network [OSTI]

Load Management has grown in acceptance over the past several decades as a reliable means to provide a demand-side resource of demand capacity. This paper first reviews the significant break-throughs of load management technology then sets the stage...

Gardner, E.

1994-01-01T23:59:59.000Z

385

Nonparametric models for electricity load forecasting  

E-Print Network [OSTI]

Electricity consumption is constantly evolving due to changes in people habits, technological innovations1 Nonparametric models for electricity load forecasting JANUARY 23, 2015 Yannig Goude, Vincent at University Paris-Sud 11 Orsay. His research interests are electricity load forecasting, more generally time

Genève, Université de

386

Static load testing of a heliostat drive  

SciTech Connect (OSTI)

The drive designed and built by the Solar Power Engineering Company (SPECO) for its large area heliostat failed under high wind loads during a winter storm. This report details the testing and analysis done to verify the load capabilities of the rebuilt heliostat drive. Changes in design and improvements in fabrication resulted in a usable drive. 12 figs., 7 tabs.

Grossman, J.W.

1991-10-01T23:59:59.000Z

387

Apparatus for loading a band saw blade  

DOE Patents [OSTI]

A band saw blade is loaded between pairs of guide wheels upon tensioning the blade by guiding the blade between pairs of spaced guide plates which define converging slots that converge toward the guide wheels. The approach is particularly useful in loading blades on underwater band saw machines used to cut radioactive materials. 2 figs.

Reeves, S.R.

1990-03-20T23:59:59.000Z

388

Thermionic converter in load-switching mode  

SciTech Connect (OSTI)

An electrical equivalent circuit is proposed for a thermionic electrogenerating element. It is suitable for calculation of transients in load-switching mode. Formulas are given for estimating circuit parameters. A sample numerical calculation is given for the transient between no-load and short-circuit regimes. The results may be employed to identify experimental data in the frequency domain.

Mendel'baum, M.A.; Es'kov, V.D.

1983-01-01T23:59:59.000Z

389

Load Forecast For use in Resource Adequacy  

E-Print Network [OSTI]

-term Electricity Demand Forecasting System 1) Obtain Daily Regional Temperatures 6) Estimate Daily WeatherLoad Forecast 2019 For use in Resource Adequacy Massoud Jourabchi #12;In today's presentation d l­ Load forecast methodology ­ Drivers of the forecast f i­ Treatment of conservation

390

Steam Load Reduction Guidance Emergency Management Program  

E-Print Network [OSTI]

Steam Load Reduction Guidance Emergency Management Program v October 2014 Steam_Load_Reduction_Guidance_DSRDSR 1.0 PurposeandScope Utilities provides steam to the campus community for space heating, hot water in the steam distribution system or the Central Energy Plant, the preservation of building infrastructure

Pawlowski, Wojtek

391

Using Utility Load Data to Estimate Demand for Space Cooling and Potential for Shiftable Loads  

SciTech Connect (OSTI)

This paper describes a simple method to estimate hourly cooling demand from historical utility load data. It compares total hourly demand to demand on cool days and compares these estimates of total cooling demand to previous regional and national estimates. Load profiles generated from this method may be used to estimate the potential for aggregated demand response or load shifting via cold storage.

Denholm, P.; Ong, S.; Booten, C.

2012-05-01T23:59:59.000Z

392

Time and Cognitive Load 1 Time and Cognitive Load in Working Memory  

E-Print Network [OSTI]

Time and Cognitive Load 1 Time and Cognitive Load in Working Memory Pierre Barrouillet*, Sophie Bourgogne Running head: Time and Cognitive Load Corresponding author: Pierre Barrouillet Pierre manuscript, published in "Journal of Experimental Psychology: Learning, Memory, and Cognition 33, 3 (2007

Paris-Sud XI, Université de

393

Active Wake Redirection Control to Improve Energy Yield (Poster)  

SciTech Connect (OSTI)

Wake effects can dramatically reduce the efficiency of waked turbines relative to the unwaked turbines. Wakes can be deflected, or 'redirected,' by applying yaw misalignment to the turbines. Yaw misalignment causes part of the rotor thrust vector to be pointed in the cross-stream direction, deflecting the flow and the wake. Yaw misalignment reduces power production, but the global increase in wind plant power due to decreased wake effect creates a net increase in power production. It is also a fairly simple control idea to implement at existing or new wind plants. We performed high-fidelity computational fluid dynamics simulations of the wake flow of the proposed Fishermen's Atlantic City Windfarm (FACW) that predict that under certain waking conditions, wake redirection can increase plant efficiency by 10%. This means that by applying wake redirection control, for a given watersheet area, a wind plant can either produce more power, or the same amount of power can be produced with a smaller watersheet area. With the power increase may come increased loads, though, due to the yaw misalignment. If misalignment is applied properly, or if layered with individual blade pitch control, though, the load increase can be mitigated. In this talk we will discuss the concept of wake redirection through yaw misalignment and present our CFD results of the FACW project. We will also discuss the implications of wake redirection control on annual energy production, and finally we will discuss plans to implement wake redirection control at FACW when it is operational.

Churchfield, M. J.; Fleming, P.; DeGeorge, E.; Bulder, B; White, S. M.

2014-10-01T23:59:59.000Z

394

Effects of pulsed-power loads upon an electric power grid  

SciTech Connect (OSTI)

Certain proposed particle-accelerator and laser experiments, and other devices related to fusion research, require multi-megawatt, repetitive power pulses, often at low (subsynchronous) frequency. While some power-delivery technologies call for a certain degree of buffering of the utility demand using capacitive, inductive, or inertial energy storage, considerations have also been made for serving such loads directly from the line. In either case, such pulsed loads represent non-traditional applications from the utility's perspective which, in certain cases, can have significant design and operational implications. This paper outlines an approach to the analysis of the effects of such loads upon the electric power grid using existing analysis techniques. The impacts studied include busvoltage flicker, transient and dynamic stability, and torsional excitation. The impact of a particular pulsed load is examined and illustrated for the power network serving the Los Alamos National Laboratory. 19 refs., 13 figs.

Smolleck, H.A.; Ranade, S.J.; Prasad, N.R. (New Mexico State Univ., Las Cruces, NM (USA). Dept. of Electrical and Computer Engineering); Velasco, R.O. (Los Alamos National Lab., NM (USA))

1990-01-01T23:59:59.000Z

395

Fuel Cell Powered Vehicles Using Supercapacitors: Device Characteristics, Control Strategies, and Simulation Results  

E-Print Network [OSTI]

using supercapacitors than batteries. The simulation resultsload-level control for batteries because of the lower lossesthe DC/DC converter and batteries, but load level control is

Zhao, Hengbing; Burke, Andy

2010-01-01T23:59:59.000Z

396

21-PWR WASTE PACKAGE WITH ABSORBER PLATES LOADING CURVE EVALUATION  

SciTech Connect (OSTI)

The objective of this calculation is to evaluate the required minimum burnup as a function of initial pressurized water reactor (PWR) assembly enrichment that would permit loading of spent nuclear fuel into the 21 PWR waste package with absorber plates design as provided in Attachment IV. This calculation is an example of the application of the methodology presented in the ''Disposal Criticality Analysis Methodology Topical Report'' (YMP 2003). The scope of this calculation covers a range of enrichments from 0 through 5.0 weight percent U-235, and a burnup range of 0 through 45 GWd/MTU. Higher burnups were not necessary because 45 GWd/MTU was high enough for the loading curve determination. This activity supports the validation of the use of burnup credit for commercial spent nuclear fuel applications. The intended use of these results will be in establishing PWR waste package configuration loading specifications. Limitations of this evaluation are as follows: (1) The results are based on burnup credit for actinides and selected fission products as proposed in YMP (2003, Table 3-1) and referred to as the ''Principal Isotopes''. Any change to the isotope listing will have a direct impact on the results of this report. (2) The results are based on 1.5 wt% Gd in the Ni-Gd Alloy material and having no tuff inside the waste package. If the Gd loading is reduced or a process to introduce tuff inside the waste package is defined, then this report would need to be reevaluated based on the alternative materials. This calculation is subject to the ''Quality Assurance Requirements and Description'' (QARD) (DOE 2004) because it concerns engineered barriers that are included in the ''Q-List'' (BSC 2004k, Appendix A) as items important to safety and waste isolation.

J.M. Scaglione

2004-12-17T23:59:59.000Z

397

Researching Complex Heat, Air and Moisture Interactions for a Wide-Range of Building Envelope Systems and Environmental Loads  

SciTech Connect (OSTI)

This document serves as the final report documenting work completed by Oak Ridge National Laboratory (ORNL) and the Fraunhofer Institute in Building Physics (Holzkirchen, Germany) under an international CRADA No. 0575 with Fraunhofer Institute of Bauphysics of the Federal Republic of Germany for Researching Complex Heat, Air and Moisture Interactions for a Wide Range of Building Envelope Systems and Environmental Loads. This CRADA required a multi-faceted approach to building envelope research that included a moisture engineering approach by blending extensive material property analysis, laboratory system and sub-system thermal and moisture testing, and advanced moisture analysis prediction performance. The Participant's Institute for Building physics (IBP) and the Contractor's Buildings Technology Center (BTC) identified potential research projects and activities capable of accelerating and advancing the development of innovative, low energy and durable building envelope systems in diverse climates. This allowed a major leverage of the limited resources available to ORNL to execute the required Department of Energy (DOE) directives in the area of moisture engineering. A joint working group (ORNL and Fraunhofer IBP) was assembled and a research plan was executed from May 2000 to May 2005. A number of key deliverables were produced such as adoption of North American loading into the WUFI-software. in addition the ORNL Weather File Analyzer was created and this has been used to address environmental loading for a variety of US climates. At least 4 papers have been co-written with the CRADA partners, and a chapter in the ASTM Manual 40 on Moisture Analysis and Condensation Control. All deliverables and goals were met and exceeded making this collaboration a success to all parties involves.

Karagiozis, A.N.

2007-05-15T23:59:59.000Z

398

Synthesis of polyoxometalate-loaded epoxy composites  

DOE Patents [OSTI]

The synthesis of a polyoxometalate-loaded epoxy uses a one-step cure by applying an external stimulus to release the acid from the polyoxometalate and thereby catalyze the cure reaction of the epoxy resin. Such polyoxometalate-loaded epoxy composites afford the cured epoxy unique properties imparted by the intrinsic properties of the polyoxometalate. For example, polyoxometalate-loaded epoxy composites can be used as corrosion resistant epoxy coatings, for encapsulation of electronics with improved dielectric properties, and for structural applications with improved mechanical properties.

Anderson, Benjamin J

2014-10-07T23:59:59.000Z

399

Directives Quarterly Updates  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

Listings of new Justification Memoranda and new or revised Directives that have been posted to the DOE Directives, Delegations, and Requirements Portal. Updated quarterly.

400

Another face of DIRECT  

E-Print Network [OSTI]

authors, see for example, tree-Direct [5]. This paper ..... [4] J.M. Gablonsky, Modifications of the DIRECT Algorithm, Ph.D. Thesis, North Carolina State. University...

chiter

2007-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

NUMERICAL MODELING OF SHOCK-INDUCED DAMAGE FOR GRANITE UNDER DYNAMIC LOADING  

E-Print Network [OSTI]

NUMERICAL MODELING OF SHOCK-INDUCED DAMAGE FOR GRANITE UNDER DYNAMIC LOADING H. A. Ai1 , T. J beneath impact crater in granite. Model constants are determined either directly from static uniaxial from Century Dynamics to simulate the shock-induced damage in granite targets impacted by projectiles

Stewart, Sarah T.

402

Economic Impact of a Trans-loading Facility January 8, 2014  

E-Print Network [OSTI]

.0 Taxes in New Mexico 6 5.1 Indirect Tax Impacts 6 5.2 Direct Taxes on Oil Production 8 6.0 Summary-loading facility in Rancho Cielo's business park to serve oil activities in the San Juan Basin of New Mexico an incentive to drill for more oil. Coast Range Investments contracted with New Mexico State University

Johnson, Eric E.

403

Joint delay and power control in single-server queueing systems  

E-Print Network [OSTI]

a non-monotonic curve of delay vs. load. This may lead to malfunctioning in end- to-end flow the service rate according to the input traffic load leads to an anomalous behavior in the delay-load curve/congestion control protocols, which are based on the assumption that delays increase with increasing load. We propose

404

Loading atom lasers by collectivity-enhanced optical pumping  

SciTech Connect (OSTI)

The effect of collectivity on the loading of an atom laser via optical pumping is discussed. In our model, atoms in a beam are laser-excited and subsequently spontaneously decay into a trapping state. We consider the case of sufficiently high particle density in the beam such that the spontaneous emission is modified by the particle interaction. We show that the collective effects lead to a better population of the trapping state over a wide range of system parameters, and that the second-order correlation function of the atoms can be controlled by the applied laser field.

Macovei, Mihai A.; Evers, Joerg [Max-Planck-Institut fuer Kernphysik, Saupfercheckweg 1, D-69117 Heidelberg (Germany)

2010-01-15T23:59:59.000Z

405

Wind/Wave Misalignment in the Loads Analysis of a Floating Offshore Wind Turbine: Preprint  

SciTech Connect (OSTI)

Wind resources far from the shore and in deeper seas have encouraged the offshore wind industry to look into floating platforms. The International Electrotechnical Commission (IEC) is developing a new technical specification for the design of floating offshore wind turbines that extends existing design standards for land-based and fixed-bottom offshore wind turbines. The work summarized in this paper supports the development of best practices and simulation requirements in the loads analysis of floating offshore wind turbines by examining the impact of wind/wave misalignment on the system loads under normal operation. Simulations of the OC3-Hywind floating offshore wind turbine system under a wide range of wind speeds, significant wave heights, peak-spectral periods and wind/wave misalignments have been carried out with the aero-servo-hydro-elastic tool FAST [4]. The extreme and fatigue loads have been calculated for all the simulations. The extreme and fatigue loading as a function of wind/wave misalignment have been represented as load roses and a directional binning sensitivity study has been carried out. This study focused on identifying the number and type of wind/wave misalignment simulations needed to accurately capture the extreme and fatigue loads of the system in all possible metocean conditions considered, and for a down-selected set identified as the generic US East Coast site. For this axisymmetric platform, perpendicular wind and waves play an important role in the support structure and including these cases in the design loads analysis can improve the estimation of extreme and fatigue loads. However, most structural locations see their highest extreme and fatigue loads with aligned wind and waves. These results are specific to the spar type platform, but it is expected that the results presented here will be similar to other floating platforms.

Barj, L.; Stewart, S.; Stewart, G.; Lackner, M.; Jonkman, J.; Robertson, A.

2014-02-01T23:59:59.000Z

406

Impact of load type on microgrid stability  

E-Print Network [OSTI]

Microgrids show great promise as a means of integrating distributed generation sources into the public grid distribution system. In order to provide uninterrupted,high quality power to local loads, microgrids must have the ...

Monnin, Jared P

2012-01-01T23:59:59.000Z

407

Gearbox Reliability Collaborative (GRC) Description and Loading  

SciTech Connect (OSTI)

This document describes simulated turbine load cases in accordance to the IEC 61400-1 Ed.3 standard, which is representative of the typical wind turbine design process. The information presented herein is intended to provide a broad understanding of the gearbox reliability collaborative 750kW drivetrain and turbine configuration. In addition, fatigue and ultimate strength drivetrain loads resulting from simulations are presented. This information provides the bases for the analytical work of the gearbox reliability collaborative effort.

Oyague, F.

2011-11-01T23:59:59.000Z

408

Optimal Control of Harvesting Ice Thermal Storage Systems  

E-Print Network [OSTI]

for optimal control of a harvesting ice storage system. A simplified procedure is used to develop 24 hour load data. Example installations will be shown....

Knebel, D. E.

1988-01-01T23:59:59.000Z

409

Comparison of Conventional Diesel and Reactivity Controlled Compressio...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

of Advanced Diesel Engine Combustion Strategies Effect of Compression Ratio and Piston Geometry on RCCI load limit High Efficiency Fuel Reactivity Controlled Compression...

410

Harmonic approaches to non-intrusive load diagnostics  

E-Print Network [OSTI]

The Non-Intrusive Load Monitor (NILM) is a system that monitors, records and processes voltage and current measurements to establish the operating characteristics of individual loads on a load center from a single aggregate ...

Fuller, Ashley E. (Ashley Eliot)

2008-01-01T23:59:59.000Z

411

Psychosocial mediators of ethnic disparities in Allostatic Load /  

E-Print Network [OSTI]

in Allostatic Load A dissertation submitted in partialPartial Associations between Posited Mediators with Ethnicity and Allostatic LoadPartial Associations between Posited Mediators with Ethnicity and Allostatic Load

Tomfohr, Lianne Marie

2013-01-01T23:59:59.000Z

412

axial compressive load: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

as the electromagnetic and thermal contraction loads are large but also for the heat load from the AC coupling loss. Reduction of the transverse load and warm-up cool-down...

413

axial compressive loading: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

as the electromagnetic and thermal contraction loads are large but also for the heat load from the AC coupling loss. Reduction of the transverse load and warm-up cool-down...

414

General solutions for thermopiezoelectrics with various holes under thermal loading  

E-Print Network [OSTI]

induced by thermal loads. The loads may be uniform remote heat ¯ow, point heat source and temperature elastic plate with an hole of various shapes subjected to remote uniform mechanical loading. For plane

Qin, Qinghua

415

Landmarks in OpenLS --A Data Structure for Cognitive Ergonomic Route Directions  

E-Print Network [OSTI]

Landmarks in OpenLS -- A Data Structure for Cognitive Ergonomic Route Directions Stefan Hansen1 ergonomic route directions in this article. They try to reduce the cognitive load for the travelers ergonomic route directions. In M. Raubal, H. Miller, A. U. Frank, & M. F. Goodchild (Eds.), GIScience

Bremen, Universität

416

1999 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The Pacific Northwest Loads and Resources Study (White Book) is published annually by BPA and establishes the planning basis for supplying electricity to customers. It serves a dual purpose. First, the White Book presents projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. Second, the White Book serves as a benchmark for annual BPA determinations made pursuant to its regional power sales contracts. Specifically, BPA uses the information in the White Book for determining the notice required when customers request to increase or decrease the amount of power purchased from BPA. The White Book will not be used in calculations for the 2002 regional power sales contract subscription process. The White Book compiles information obtained from several formalized resource planning reports and data submittals, including those from the Northwest Power Planning Council (Council) and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for determining BPA revenues. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions, including expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. In this loads and resources study, resource availability is compared with a medium forecast of electricity consumption. The forecasted future electricity demands--firm loads--are subtracted from the projected capability of existing and ''contracted for'' resources to determine whether BPA and the region will be surplus or deficit. If Federal system resources are greater than loads in any particular year or month, there is a surplus of energy and/or capacity, which BPA may use or market to increase revenues. Conversely, if Federal system firm loads exceed available resources, there is a deficit of energy and/or capacity and BPA would add conservation or contract purchases as needed to meet its firm loads. The load forecast is derived by using econometric models and analysis to predict the loads that will be placed on electric utilities in the region. This study incorporates information on contract obligations and contract resources, combined with the resource capabilities obtained from public utility and investor-owned utility (IOU) customers through their annual data submittals to the PNUCC, from BPA's Firm Resource Exhibit (FRE Exhibit I) submittals, and through analysis of the Federal hydroelectric power system. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA) produced by the Pacific Northwest Coordinating Group. The PNCA defines the planning and operation of the regional hydrosystem. The 1999 White Book is presented in two documents: (1) this summary of Federal system and Pacific Northwest region loads and resources; and (2) a technical appendix (available electronically only) detailing the loads and resources for each major Pacific Northwest generating utility. This analysis updates the December 1998 Pacific Northwest Loads and Resources Study. This analysis projects the yearly average energy consumption and resource availability for Operating Years (OY) 2000-01 through 2009-10. The study shows the Federal system's and the region's monthly estimated maximum electricity demand, monthly energy demand, monthly energy generation, and monthly maximum generating capability--capacity--for OY 2000-01, 2004-05, and 2009-10. The Federal system and regional monthly capacity surplus/deficit projections are summarized for 10 operating years. This document analyzes the Pacific Northwest's projected loads and available generating resources in two parts: (1) the loads and resources of the Federal system, for wh

United States. Bonneville Power Administration.

1999-12-01T23:59:59.000Z

417

Electric power generating plant having direct-coupled steam and compressed-air cycles  

DOE Patents [OSTI]

An electric power generating plant is provided with a Compressed Air Energy Storage (CAES) system which is directly coupled to the steam cycle of the generating plant. The CAES system is charged by the steam boiler during off peak hours, and drives a separate generator during peak load hours. The steam boiler load is thereby levelized throughout an operating day.

Drost, M.K.

1981-01-07T23:59:59.000Z

418

Electric power generating plant having direct coupled steam and compressed air cycles  

DOE Patents [OSTI]

An electric power generating plant is provided with a Compressed Air Energy Storage (CAES) system which is directly coupled to the steam cycle of the generating plant. The CAES system is charged by the steam boiler during off peak hours, and drives a separate generator during peak load hours. The steam boiler load is thereby levelized throughout an operating day.

Drost, Monte K. (Richland, WA)

1982-01-01T23:59:59.000Z

419

Wind Turbine Control Design to Reduce Capital Costs: 7 January 2009 - 31 August 2009  

SciTech Connect (OSTI)

This report first discusses and identifies which wind turbine components can benefit from advanced control algorithms and also presents results from a preliminary loads case analysis using a baseline controller. Next, it describes the design, implementation, and simulation-based testing of an advanced controller to reduce loads on those components. The case-by-case loads analysis and advanced controller design will help guide future control research.

Darrow, P. J.

2010-01-01T23:59:59.000Z

420

Transmission Reliability "Load as a Resource" Peer Review Materials...  

Broader source: Energy.gov (indexed) [DOE]

Transmission Reliability "Load as a Resource" Peer Review Materials Now Available Transmission Reliability "Load as a Resource" Peer Review Materials Now Available September 25,...

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Y-12 Finishes Initial HEUMF Loading Ahead of Schedule | National...  

National Nuclear Security Administration (NNSA)

Home Field Offices Welcome to the NNSA Production Office NPO News Releases Y-12 Finishes Initial HEUMF Loading Ahead of Schedule Y-12 Finishes Initial HEUMF Loading...

422

acute acid loading an: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

7 queries Meagher, Mary 29 An Automatic Load Sharing Approach for a DFIG Based Wind Generator in a Microgrid Engineering Websites Summary: An Automatic Load Sharing Approach...

423

Characterization of Dynamic Loads on Solar Modules with Respect...  

Broader source: Energy.gov (indexed) [DOE]

Characterization of Dynamic Loads on Solar Modules with Respect to Fracture of Solar Cells Characterization of Dynamic Loads on Solar Modules with Respect to Fracture of Solar...

424

Effect of Compression Ratio and Piston Geometry on RCCI load...  

Broader source: Energy.gov (indexed) [DOE]

Compression Ratio and Piston Geometry on RCCI load limit Effect of Compression Ratio and Piston Geometry on RCCI load limit Explores the effect of compression ratio and piston...

425

Development of an Accelerated Ash-Loading Protocol for Diesel...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

an Accelerated Ash-Loading Protocol for Diesel Particulate Filters Development of an Accelerated Ash-Loading Protocol for Diesel Particulate Filters Poster presentation at the 2007...

426

The Development of a Small Engine Based Accelerated Ash Loading...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Accelerated Ash Loading Protocol The Development of a Small Engine Based Accelerated Ash Loading Protocol Presentation given at DEER 2006, August 20-24, 2006, Detroit, Michigan....

427

Local Soot Loading Distribution in Cordierite Diesel Particulate...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Local Soot Loading Distribution in Cordierite Diesel Particulate Filters by Dynamic Neutron Radiography Local Soot Loading Distribution in Cordierite Diesel Particulate Filters by...

428

Effects of Gasoline Direct Injection Engine Operating Parameters on Particle Number Emissions  

SciTech Connect (OSTI)

A single-cylinder, wall-guided, spark ignition direct injection engine was used to study the impact of engine operating parameters on engine-out particle number (PN) emissions. Experiments were conducted with certification gasoline and a splash blend of 20% fuel grade ethanol in gasoline (E20), at four steady-state engine operating conditions. Independent engine control parameter sweeps were conducted including start of injection, injection pressure, spark timing, exhaust cam phasing, intake cam phasing, and air-fuel ratio. The results show that fuel injection timing is the dominant factor impacting PN emissions from this wall-guided gasoline direct injection engine. The major factor causing high PN emissions is fuel liquid impingement on the piston bowl. By avoiding fuel impingement, more than an order of magnitude reduction in PN emission was observed. Increasing fuel injection pressure reduces PN emissions because of smaller fuel droplet size and faster fuel-air mixing. PN emissions are insensitive to cam phasing and spark timing, especially at high engine load. Cold engine conditions produce higher PN emissions than hot engine conditions due to slower fuel vaporization and thus less fuel-air homogeneity during the combustion process. E20 produces lower PN emissions at low and medium loads if fuel liquid impingement on piston bowl is avoided. At high load or if there is fuel liquid impingement on piston bowl and/or cylinder wall, E20 tends to produce higher PN emissions. This is probably a function of the higher heat of vaporization of ethanol, which slows the vaporization of other fuel components from surfaces and may create local fuel-rich combustion or even pool-fires.

He, X.; Ratcliff, M. A.; Zigler, B. T.

2012-04-19T23:59:59.000Z

429

Staged direct injection diesel engine  

DOE Patents [OSTI]

A diesel engine having staged injection for using lower cetane number fuels than No. 2 diesel fuel. The engine includes a main fuel injector and a pilot fuel injector. Pilot and main fuel may be the same fuel. The pilot injector injects from five to fifteen percent of the total fuel at timings from 20.degree. to 180.degree. BTDC depending upon the quantity of pilot fuel injected, the fuel cetane number and speed and load. The pilot fuel injector is directed toward the centerline of the diesel cylinder and at an angle toward the top of the piston, avoiding the walls of the cylinder. Stratification of the early injected pilot fuel is needed to reduce the fuel-air mixing rate, prevent loss of pilot fuel to quench zones, and keep the fuel-air mixture from becoming too fuel lean to become effective. In one embodiment, the pilot fuel injector includes a single hole for injection of the fuel and is directed at approximately 48.degree. below the head of the cylinder.

Baker, Quentin A. (San Antonio, TX)

1985-01-01T23:59:59.000Z

430

Directives Quarterly Updates - DOE Directives, Delegations, and  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-Series to UserProduct: https://www.directives.doe.gov/directives/directives

431

Automatic On-line Controller for Coordinated Slow Voltage Control  

E-Print Network [OSTI]

are operated in an "aligned" operation. In modern power systems, as the system gets loaded more and more, reactor banks and LTC transformers. The project pursues a model-based approach for selecting the discrete switching cost. A robust control strategy is proposed to make the control feasible and optimal for a set

Venkatasubramanian, Mani V.

432

Comparison of direct plating versus filtering of egg shells inoculated with Salmonella typhimurium  

E-Print Network [OSTI]

Comparison of enumeration of egg shell bacterial load by a conventional direct plating method and a neoteric filtering method was evaluated. Egg shells were inoculated with approximately 10 S. typhimurium organisms. Initial experiments evaluated...

Reynolds, Paige Lea

2012-06-07T23:59:59.000Z

433

Parameter sensitivity analysis of tailored-pulse loading stimulation of Devonian gas shale  

SciTech Connect (OSTI)

An evaluation of three tailored-pulse loading parameters has been undertaken to access their importance in gas well stimulation technology. This numerical evaluation was performed using STEALTH finite-difference codes and was intended to provide a measure of the effects of various tailored-pulse load configurations on fracture development in Devonian gas shale. The three parameters considered in the sensitivity analysis were: loading rate; decay rate; and sustained peak pressures. By varying these parameters in six computations and comparing the relative differences in fracture initiation and propagation the following conclusions were drawn: (1) Fracture initiation is directly related to the loading rate aplied to the wellbore wall. Loading rates of 10, 100 and 1000 GPa/sec were modeled. (2) If yielding of the rock can be prevented or minimized, by maintaining low peak pressures in the wellbore, increasing the pulse loading rate, to say 10,000 GPa/sec or more, should initiate additional multiple fractures. (3) Fracture initiation does not appear to be related to the tailored-pulse decay rate. Fracture extension may be influenced by the rate of decay. The slower the decay rate, the longer the crack extension. (4) Fracture initiation does not appear to be improved by a high pressure plateau in the tailored-pulse. Fracture propagation may be enhanced if the maintained wellbore pressure plateau is of sufficient magnitude to extent the range of the tangential tensile stresses to greater radial distances. 26 figures, 2 tables.

Barbour, T.G.; Mihalik, G.R.

1980-11-01T23:59:59.000Z

434

1993 Pacific Northwest Loads and Resources Study, Pacific Northwest Economic and Electricity Use Forecast, Technical Appendix: Volume 1.  

SciTech Connect (OSTI)

This publication documents the load forecast scenarios and assumptions used to prepare BPA`s Whitebook. It is divided into: intoduction, summary of 1993 Whitebook electricity demand forecast, conservation in the load forecast, projection of medium case electricity sales and underlying drivers, residential sector forecast, commercial sector forecast, industrial sector forecast, non-DSI industrial forecast, direct service industry forecast, and irrigation forecast. Four appendices are included: long-term forecasts, LTOUT forecast, rates and fuel price forecasts, and forecast ranges-calculations.

United States. Bonneville Power Administration.

1994-02-01T23:59:59.000Z

435

Autonomous grain combine control system  

DOE Patents [OSTI]

A system for controlling a grain combine having a rotor/cylinder, a sieve, a fan, a concave, a feeder, a header, an engine, and a control system. The feeder of the grain combine is engaged and the header is lowered. A separator loss target, engine load target, and a sieve loss target are selected. Grain is harvested with the lowered header passing the grain through the engaged feeder. Separator loss, sieve loss, engine load and ground speed of the grain combine are continuously monitored during the harvesting. If the monitored separator loss exceeds the selected separator loss target, the speed of the rotor/cylinder, the concave setting, the engine load target, or a combination thereof is adjusted. If the monitored sieve loss exceeds the selected sieve loss target, the speed of the fan, the size of the sieve openings, or the engine load target is adjusted.

Hoskinson, Reed L.; Kenney, Kevin L.; Lucas, James R.; Prickel, Marvin A.

2013-06-25T23:59:59.000Z

436

On-line Load Balancing for Related Machines 1 Piotr Berman  

E-Print Network [OSTI]

s and Load(s), the load of entire schedule s as follows: load(s;i) = 1 vi X s(j)=i pj; Load(s) = maxi loadOn-line Load Balancing for Related Machines 1 (Revised Version) Piotr Berman The Pennsylvania State for this problem. Key Words: on-line algorithm, load balancing, related machines, competitive ratio 1A preliminary

Eckmiller, Rolf

437

Dielectric breakdown model for conductor-loaded and insulator-loaded composite materials P. Bergero,1  

E-Print Network [OSTI]

Dielectric breakdown model for conductor-loaded and insulator-loaded composite materials P. Bergero strength is highly desirable, and in the past years composite materials such as resin matrix filled- tors, and composites containing carbon black and titanium dioxide have recently been tested

Peruani, Fernando

438

Reconstruction of a wind turbine's endured load spectrum using a short-time load measurement  

E-Print Network [OSTI]

Reconstruction of a wind turbine's endured load spectrum using a short-time load measurement Abstract Wind turbines (WT) are normally designed for a service life (SL) of 20 years. In Germany, over safety. 1 Introduction A wind turbine (WT) is normally designed, tested and certified for a design life

Berlin,Technische Universität

439

Improved Load Distribution for Load Rating of Low-Fill Box Structures  

E-Print Network [OSTI]

. The distribution of live loads on the top slab of a box culvert plays a major role in determining the rating factor of the culvert. The current AASHTO guidelines do not consider the effects of pavements present above the fill while determining the load distribution...

Acharya, Raju

2012-12-31T23:59:59.000Z

440

Modality Effects on Cognitive Load and Performance in High-Load Information Presentation  

E-Print Network [OSTI]

INTRODUCTION Intelligent human-computer interfaces are often multimodal, i.e. the human-computer communications into the modality planning procedure for systems that support high-load human-computer interaction. Author Keywords-load information presenta- tion scenario. Mainly based on modality-related psychology theories, we selected five

Nijholt, Anton

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Direct/Indirect Costs  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This chapter provides recommended categories for direct and indirect elements developed by the Committee for Cost Methods Development (CCMD) and describes various estimating techniques for direct and indirect costs.

1997-03-28T23:59:59.000Z

442

Direct Loan Program (Connecticut)  

Broader source: Energy.gov [DOE]

The Connecticut Development Authoritys Direct Loan Program provides direct senior and subordinated loans and mezzanine investments to companies creating or maintaining jobs. Up to $20,000 per job...

443

Control Categories Control Category  

E-Print Network [OSTI]

/ Conversion Controls Controls over moving data between computer systems. Process used to migrate data fromControl Categories Control Category Legend Description Example Authorization Approval policies and procedures. Authorization limits. Configuration/ Account Mapping "Switches" to secure data

444

Rocky Mountain Power- Self-Direction Credit Program  

Broader source: Energy.gov [DOE]

Rocky Mountain Power offers a Self-Direction Credit program to its industrial and large commercial customers with annual electric usage of more than 5,000,000 kWh or a 1,000 kW peak load. Through...

445

Rocky Mountain Power- Self-Direction Credit Program  

Broader source: Energy.gov [DOE]

Rocky Mountain Power offers a Self-Direction Credit program to its industrial and large commercial customers with annual electric usage of more than 5 million kWh or a peak load of 1,000 kW or more...

446

Directives System Manual  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Manual provides detailed requirements to supplement DOE O 251.1A, Directives System, dated 1-30-98.

1998-01-30T23:59:59.000Z

447

Direct process for explosives  

DOE Patents [OSTI]

A direct process of making ethylenediamine dinitrate through the reaction of ethylenediamine and ammonium nitrate is described.

Akst, I.B.; Stinecipher, M.M.

1982-10-12T23:59:59.000Z

448

Control rod cluster arrangement  

SciTech Connect (OSTI)

This patent describes a nuclear reactor including nuclear core which is cooled and moderated by light water, the nuclear core comprising a plurality of parallel arranged openings therethrough and interspersed among the fuel assemblies. A control rod cluster arrangement comprises load follow control rod cluster assemblies with each load follow control rod cluster assembly being adapted to slidingly fit within each of some of the fuel assemblies in the parallel arranged openings, the load follow control rod cluster assemblies each comprising a plurality of elongated parallel arranged rods attached to a single spider, and including a first group of rods and a second group of rods, the first group of rods and the second each consisting of a plurality of absorber rods. The first group of rods consist of absorber rods taken from the group consisting of B/sub 4/C, hafnium, or silver-indium-cadmium and the second group of rods consist of absorber rods each consisting of stainless steel, the first group of rods and the second group of rods each being integrally attached at all times to the single spider, the absorber rods of the second group of rods being dispersed throughout the control rod cluster assembly. The first group of rods have a first neutron capture cross section and the second group of rods have a second neutron capture cross section different from the first cross section.

Orr, W.L.; Doshi, P.K.; Mildrum, C.M.; Freeman, T.R.

1987-02-10T23:59:59.000Z

449

Sandia National Laboratories: Grand Challenge Laboratory-Directed...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Grand Challenge Laboratory-Directed Research and Development project Recent Sandia Secure, Scalable Microgrid Advanced Controls Research Accomplishments On March 3, 2015, in...

450

System for loading executable code into volatile memory in a downhole tool  

DOE Patents [OSTI]

A system for loading an executable code into volatile memory in a downhole tool string component comprises a surface control unit comprising executable code. An integrated downhole network comprises data transmission elements in communication with the surface control unit and the volatile memory. The executable code, stored in the surface control unit, is not permanently stored in the downhole tool string component. In a preferred embodiment of the present invention, the downhole tool string component comprises boot memory. In another embodiment, the executable code is an operating system executable code. Preferably, the volatile memory comprises random access memory (RAM). A method for loading executable code to volatile memory in a downhole tool string component comprises sending the code from the surface control unit to a processor in the downhole tool string component over the network. A central processing unit writes the executable code in the volatile memory.

Hall, David R. (Provo, UT); Bartholomew, David B. (Springville, UT); Johnson, Monte L. (Orem, UT)

2007-09-25T23:59:59.000Z

451

Adaptive Energy Consumption Scheduling with Load Uncertainty for the Smart Grid  

E-Print Network [OSTI]

including must-run and controllable. Unlike most of the existing demand side management algorithms to as demand side management (DSM). Among different techniques con- sidered for DSM (e.g., voluntary load electricity price to the demand side, users pay what the electricity is worth at different times of day

Wong, Vincent

452

Dynamic Load Altering Attacks in Smart Grid Sajjad Amini, Hamed Mohsenian-Rad, and Fabio Pasqualetti  

E-Print Network [OSTI]

response and demand side management programs. It attempts to control and change certain unsecured is on attacks against demand re- sponse (DR) and demand side management (DSM) programs. DR programs are used}@ece.ucr.edu and fabiopas@engr.ucr.edu Abstract--A load altering attack (LAA) is a cyber-physical attack against demand

Mohsenian-Rad, Hamed

453

Hydrodynamic Coefficients and Wave Loads for a WEC Device in Heaving Mode  

E-Print Network [OSTI]

. This model is intended to be used for WEC control purposes. A semi-analytical approach is therefore proposed for the computation of the hydrodynamic coefficients and the excitation forces. The boundary value problem is solved--Wave Energy Converter, potential theory, eigen- function expansion, wave-loads, heaving mode, scattering

Paris-Sud XI, Université de

454

IN-SERVICE LOAD & RESISTANCE FACTOR RATING METHOD FOR BRIDGES  

E-Print Network [OSTI]

Stress Rating method (noted ASR in the following), Load Factor Rating method (noted LFR in the followingIN-SERVICE LOAD & RESISTANCE FACTOR RATING METHOD FOR BRIDGES Degang Li1 , Baidurya Bhattacharya2 are evaluated using allowable stress and load factor rating methods. Load rating made in these traditional

Bhattacharya, Baidurya

455

Randomized Load Balancing by Joining and Splitting Bins James Aspnes  

E-Print Network [OSTI]

Consider the following load balancing scenario: a certain amount of work load is distributed among a setRandomized Load Balancing by Joining and Splitting Bins James Aspnes Yitong Yin § 1 Introduction, one of the existing machines gives some of its load to the new machine; and upon a departure

Aspnes, James

456

Classification and forecasting of load curves Nolwen Huet  

E-Print Network [OSTI]

Classification and forecasting of load curves Nolwen Huet Abstract The load curve, which gives of electricity customer uses. This load curve is only available for customers with automated meter reading. For the others, EDF must estimate this curve. Usually a clustering of the load curves is performed, followed

Cuesta, Juan Antonio

457

Discharge indices for water quality loads Richard M. Vogel  

E-Print Network [OSTI]

: effective discharge, transport, sediment, constituents, rating curve, half-load Citation: Vogel, R. M., J. RDischarge indices for water quality loads Richard M. Vogel Department of Civil and Environmental load is ultimately the quantity of interest, we define a new index, the half-load discharge, which

Vogel, Richard M.

458

ANALYTICAL APPROACH TO TRANSIENT HEAT CONDUCTION IN COOLING LOAD CALCULATIONS  

E-Print Network [OSTI]

equation in cooling load calculations. The performance of nine different procedures (the four methods and

Michal Duka; Martin Bartk; Frantiek Drkal; Jan Hensen

459

Demand-Side Response from Industrial Loads  

SciTech Connect (OSTI)

Through a research study funded by the Department of Energy, Smart Grid solutions company ENBALA Power Networks along with the Oak Ridge National Laboratory (ORNL) have geospatially quantified the potential flexibility within industrial loads to leverage their inherent process storage to help support the management of the electricity grid. The study found that there is an excess of 12 GW of demand-side load flexibility available in a select list of top industrial facilities in the United States. Future studies will expand on this quantity of flexibility as more in-depth analysis of different industries is conducted and demonstrations are completed.

Starke, Michael R [ORNL; Alkadi, Nasr E [ORNL; Letto, Daryl [Enbala Power Networks; Johnson, Brandon [University of Tennessee, Knoxville (UTK); Dowling, Kevin [University of Tennessee, Knoxville (UTK); George, Raoule [Enbala Power Networks; Khan, Saqib [University of Texas, Austin

2013-01-01T23:59:59.000Z

460

Low profile, high load vertical rolling positioning stage  

DOE Patents [OSTI]

A stage or support platform assembly for use in a synchrotron accurately positions equipment to be used in the beam line of the synchrotron. The support platform assembly includes an outer housing in which is disposed a lifting mechanism having a lifting platform or stage at its upper extremity on which the equipment is mounted. A worm gear assembly is located in the housing and is adapted to raise and lower a lifting shaft that is fixed to the lifting platform by an anti-binding connection. The lifting platform is moved vertically as the lifting shaft is moved vertically. The anti-binding connection prevents the shaft from rotating with respect to the platform, but does permit slight canting of the shaft with respect to the lifting platform so as to eliminate binding and wear due to possible tolerance mismatches. In order to ensure that the lifting mechanism does not move in a horizontal direction as it is moved vertically, at least three linear roller bearing assemblies are arranged around the outer-periphery of the lifting mechanism. One of the linear roller bearing assemblies can be adjusted so that the roller bearings apply a loading force against the lifting mechanism. Alternatively, a cam mechanism can be used to provide such a loading force.

Shu, Deming (Darien, IL); Barraza, Juan (Aurora, IL)

1996-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Design and control of a self-sensing piezoelectric reticle assist device  

E-Print Network [OSTI]

This thesis presents the design and control techniques of a device for managing the inertial loads on photoreticle of lithography scanners. Reticle slip, resulting from large inertial loads, is a factor limiting the ...

Amin-Shahidi, Darya

2013-01-01T23:59:59.000Z

462

Options for Cryogenic Load Cooling with Forced Flow Helium Circulation  

SciTech Connect (OSTI)

Cryogenic pumps designed to circulate super-critical helium are commonly deemed necessary in many super-conducting magnet and other cooling applications. Acknowledging that these pumps are often located at the coldest temperature levels, their use introduces risks associated with the reliability of additional rotating machinery and an additional load on the refrigeration system. However, as it has been successfully demonstrated, this objective can be accomplished without using these pumps by the refrigeration system, resulting in lower system input power and improved reliability to the overall cryogenic system operations. In this paper we examine some trade-offs between using these pumps vs. using the refrigeration system directly with examples of processes that have used these concepts successfully and eliminated using such pumps

Peter Knudsen, Venkatarao Ganni, Roberto Than

2012-06-01T23:59:59.000Z

463

Directives Templates - DOE Directives, Delegations, and Requirements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May JunDatastreamsmmcrcalgovInstrumentsruc DocumentationP-Series to UserProduct:Directives Templates by Website Administrator Directives

464

A Note on Online Load Balancing for Related Machines  

E-Print Network [OSTI]

(j) that will execute it. We define the load of a machine i and the load of entire schedule s as follows: load(s; i) = 1A Note on On­line Load Balancing for Related Machines Piotr Berman \\Lambda Marek Karpinski y that differ in speed but are related in the following sence: a job of size p requires time p=v on a machine

Eckmiller, Rolf

465

Carbon aerogel electrodes for direct energy conversion  

DOE Patents [OSTI]

A direct energy conversion device, such as a fuel cell, using carbon aerogel electrodes is described, wherein the carbon aerogel is loaded with a noble catalyst, such as platinum or rhodium and soaked with phosphoric acid, for example. A separator is located between the electrodes, which are placed in a cylinder having plate current collectors positioned adjacent the electrodes and connected to a power supply, and a pair of gas manifolds, containing hydrogen and oxygen positioned adjacent the current collectors. Due to the high surface area and excellent electrical conductivity of carbon aerogels, the problems relative to high polarization resistance of carbon composite electrodes conventionally used in fuel cells are overcome. 1 fig.

Mayer, S.T.; Kaschmitter, J.L.; Pekala, R.W.

1997-02-11T23:59:59.000Z

466

Carbon aerogel electrodes for direct energy conversion  

DOE Patents [OSTI]

A direct energy conversion device, such as a fuel cell, using carbon aerogel electrodes, wherein the carbon aerogel is loaded with a noble catalyst, such as platinum or rhodium and soaked with phosphoric acid, for example. A separator is located between the electrodes, which are placed in a cylinder having plate current collectors positioned adjacent the electrodes and connected to a power supply, and a pair of gas manifolds, containing hydrogen and oxygen positioned adjacent the current collectors. Due to the high surface area and excellent electrical conductivity of carbon aerogels, the problems relative to high polarization resistance of carbon composite electrodes conventionally used in fuel cells are overcome.

Mayer, Steven T. (San Leandro, CA); Kaschmitter, James L. (Pleasanton, CA); Pekala, Richard W. (Pleasant Hill, CA)

1997-01-01T23:59:59.000Z

467

Bi-Directional Fast Charging Study Report  

SciTech Connect (OSTI)

This report details the hardware and software infrastructure needed to demonstrate the possibility of utilizing battery power in plug-in hybrid electric vehicles (PHEVs) and electric vehicles (EVs) with a bi directional fast charger to support/offset peak building loads. This document fulfills deliverable requirements for Tasks 1.2.1.2, 1.2.1.3, and 1.2.1.4 of Statement of Work (SOW) No.5799 for Electric Transportation Engineering Corporation, now ECOtality North America (NA) support for the Idaho National Laboratory (INL).

Tyler Gray

2012-02-01T23:59:59.000Z

468

Direct access inter-process shared memory  

DOE Patents [OSTI]

A technique for directly sharing physical memory between processes executing on processor cores is described. The technique includes loading a plurality of processes into the physical memory for execution on a corresponding plurality of processor cores sharing the physical memory. An address space is mapped to each of the processes by populating a first entry in a top level virtual address table for each of the processes. The address space of each of the processes is cross-mapped into each of the processes by populating one or more subsequent entries of the top level virtual address table with the first entry in the top level virtual address table from other processes.

Brightwell, Ronald B; Pedretti, Kevin; Hudson, Trammell B

2013-10-22T23:59:59.000Z

469

EIS-0123: Direct Service Industry Options  

Broader source: Energy.gov [DOE]

BPA proposes to implement one or more options to reduce load fluctuations and revenue uncertainty resulting from its electrical service to 10 aluminum smelters and its other direct service industrial customers. BPA believes these options will give BPA greater ability to plan for power needs and help to maintain its relatively strong financial position during the current period of power surplus. They also are expected to enhance BPA's ability to repay the U.S. Treasury. In turn, BPA rates to other customers would stabilize.

470

Analysis of the Load Impacts and Economic  

E-Print Network [OSTI]

of the Time of Use (TOU) rate plan, called "Analysis of the Load Impacts and Economic Benefits model. The TOU data was rerun through the new spreadsheet model and the results are reported here. · Participation in the TOU rate option also resulted in an average net reduction of 292 kWh/year in annual

471

Improving Electric Load Forecasts Using Network Committees  

E-Print Network [OSTI]

, King Fahd University of Petroleum and Minerals, Dhahran 31261, Saudi Arabia Address for corresponding author: Dr. R. E. Abdel-Aal P. O. Box 1759 KFUPM Dhahran 31261 Saudi Arabia e-mail: radwan load and weather data at power utilities has encouraged the use of data-based machine learning modeling

Abdel-Aal, Radwan E.

472

Fig. 1. Example System phase loads  

E-Print Network [OSTI]

power system (SPS) consists of various components such as generators, cables, switchboards, load centers Transformer 9 25 12 Alternate path Generator switchboard Bus-tie breaker Generator 1 Generator 3 Generator 2 4 26 G 29 7 8 ABT 3 single phase cables Visualization for Shipboard Power Systems Karen L. Butler

473

Load forecast and treatment of conservation  

E-Print Network [OSTI]

conservation is implicitly incorporated in the short-term demand forecast? #12;3 Incorporating conservationLoad forecast and treatment of conservation July 28th 2010 Resource Adequacy Technical Committee in the short-term model Our short-term model is an econometric model which can not explicitly forecast

474

Load responsive multilayer insulation performance testing  

SciTech Connect (OSTI)

Cryogenic insulation designed to operate at various pressures from one atmosphere to vacuum, with high thermal performance and light weight, is needed for cryogenically fueled space launch vehicles and aircraft. Multilayer insulation (MLI) performs well in a high vacuum, but the required vacuum shell for use in the atmosphere is heavy. Spray-on foam insulation (SOFI) is often used in these systems because of its light weight, but can have a higher heat flux than desired. We report on the continued development of Load Responsive Multilayer Insulation (LRMLI), an advanced thermal insulation system that uses dynamic beam discrete spacers that provide high thermal performance both in atmosphere and vacuum. LRMLI consists of layers of thermal radiation barriers separated and supported by micromolded polymer spacers. The spacers have low thermal conductance, and self-support a thin, lightweight vacuum shell that provides internal high vacuum in the insulation. The dynamic load responsive spacers compress to support the external load of a vacuum shell in one atmosphere, and decompress under reduced atmospheric pressure for lower heat leak. Structural load testing was performed on the spacers with various configurations. LRMLI was installed on a 400 liter tank and boil off testing with liquid nitrogen performed at various chamber pressures from one atmosphere to high vacuum. Testing was also performed with an MLI blanket on the outside of the LRMLI.

Dye, S.; Kopelove, A. [Quest Thermal Group, 6452 Fig Street Suite A, Arvada, CO 80004 (United States); Mills, G. L. [Ball Aerospace and Technologies Corp, 1600 Commerce Street, Boulder, CO 80301 (United States)

2014-01-29T23:59:59.000Z

475

Valve for fuel pin loading system  

DOE Patents [OSTI]

A cyclone valve surrounds a wall opening through which cladding is projected. An axial valve inlet surrounds the cladding. Air is drawn through the inlet by a cyclone stream within the valve. An inflatable seal is included to physically engage a fuel pin subassembly during loading of fuel pellets.

Christiansen, D.W.

1984-01-01T23:59:59.000Z

476

Valve for fuel pin loading system  

DOE Patents [OSTI]

A cyclone valve surrounds a wall opening through which cladding is projected. An axial valve inlet surrounds the cladding. Air is drawn through the inlet by a cyclone stream within the valve. An inflatable seal is included to physically engage a fuel pin subassembly during loading of fuel pellets.

Christiansen, David W. (Kennewick, WA)

1985-01-01T23:59:59.000Z

477

Fuel loading and homogeneity analysis of HFIR design fuel plates loaded with uranium silicide fuel  

SciTech Connect (OSTI)

Twelve nuclear reactor fuel plates were analyzed for fuel loading and fuel loading homogeneity by measuring the attenuation of a collimated X-ray beam as it passed through the plates. The plates were identical to those used by the High Flux Isotope Reactor (HFIR) but were loaded with uranium silicide rather than with HFIR`s uranium oxide fuel. Systematic deviations from nominal fuel loading were observed as higher loading near the center of the plates and underloading near the radial edges. These deviations were within those allowed by HFIR specifications. The report begins with a brief background on the thermal-hydraulic uncertainty analysis for the Advanced Neutron Source (ANS) Reactor that motivated a statistical description of fuel loading and homogeneity. The body of the report addresses the homogeneity measurement techniques employed, the numerical correction required to account for a difference in fuel types, and the statistical analysis of the resulting data. This statistical analysis pertains to local variation in fuel loading, as well as to ``hot segment`` analysis of narrow axial regions along the plate and ``hot streak`` analysis, the cumulative effect of hot segment loading variation. The data for all twelve plates were compiled and divided into 20 regions for analysis, with each region represented by a mean and a standard deviation to report percent deviation from nominal fuel loading. The central regions of the plates showed mean values of about +3% deviation, while the edge regions showed mean values of about {minus}7% deviation. The data within these regions roughly approximated random samplings from normal distributions, although the chi-square ({chi}{sup 2}) test for goodness of fit to normal distributions was not satisfied.

Blumenfeld, P.E.

1995-08-01T23:59:59.000Z

478

2004 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The Pacific Northwest Loads and Resources Study (White Book), which is published annually by the Bonneville Power Administration (BPA), establishes one of the planning bases for supplying electricity to customers. The White Book contains projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. The White Book also contains information obtained from formalized resource planning reports and data submittals including those from individual utilities, the Northwest Power and Conservation Council (Council), and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for determining BPA revenues, although the database that generates the data for the White Book analysis contributes to the development of BPA's inventory and ratemaking processes. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions that include expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. The load resource balance of BPA and/or the region is determined by comparing resource availability to an expected level of total retail electricity consumption. Resources include projected energy capability plus contract purchases. Loads include a forecast of retail obligations plus contract obligations. Surplus energy is available when resources are greater than loads. This energy could be marketed to increase revenues. Energy deficits occur when resources are less than loads. These deficits could be met by any combination of the following: better-than-critical water conditions, demand-side management and conservation programs, permanent loss of loads due to economic conditions or closures, additional contract purchases, and/or the addition of new generating resources. The loads and resources analysis in this study simulates the operation of the power system under the current Pacific Northwest Coordination Agreement (PNCA). The PNCA defines the planning and operation of seventeen U.S. Pacific Northwest utilities and other parties with generating facilities within the region's hydroelectric (hydro) system. The hydroregulation study used for the 2004 White Book incorporates measures from the National Oceanographic and Atmospheric Administration Fisheries (NOAA Fisheries) Biological Opinion dated December 2000, and the U.S. Fish and Wildlife Service's 2000 Biological Opinion (2000 FCRPS BiOps) for the Snake River and Columbia River projects. These measures include: (1) Increased flow augmentation for juvenile fish migrations in the Snake and Columbia rivers in the spring and summer; (2) Mandatory spill requirements at the Lower Snake and Columbia dams to provide for non-turbine passage routes for juvenile fish migrants; and (3) Additional flows for Kootenai River white sturgeon in the spring; The hydroregulation criteria for this analysis includes the following: (1) Detailed Operation Plan operation for Treaty reservoirs for Operating Year (OY) 2004; (2) PNCA planning criteria for OY 2004; and (3) Juvenile fish bypass spill levels for 2000 FCRPS BiOps implementation. The 2004 White Book is presented in two documents: (1) this summary document of Federal system and PNW region loads and resources, and (2) a technical appendix which presents regional loads, grouped by major PNW utility categories, and detailed contract and resource information. The technical appendix is available only in electronic form. Individual customer information for marketer contracts is not detailed due to confidentiality agreements. The 2004 White Book analysis updates the 2003 White Book. This analysis projects the yearly average energy consumption and resource availability for the study period, OY 2006 through 2015. The study shows the Federal s

United States. Bonneville Power Administration.

2004-12-01T23:59:59.000Z

479

2003 Pacific Northwest Loads and Resources Study.  

SciTech Connect (OSTI)

The Pacific Northwest Loads and Resources Study (White Book), which is published annually by the Bonneville Power Administration (BPA), establishes one of the planning bases for supplying electricity to customers. The White Book contains projections of regional and Federal system load and resource capabilities, along with relevant definitions and explanations. The White Book also contains information obtained from formalized resource planning reports and data submittals including those from individual utilities, the Northwest Power and Conservation Council (Council), and the Pacific Northwest Utilities Conference Committee (PNUCC). The White Book is not an operational planning guide, nor is it used for determining BPA revenues, although the database that generates the data for the White Book analysis contributes to the development of BPA's inventory and ratemaking processes. Operation of the Federal Columbia River Power System (FCRPS) is based on a set of criteria different from that used for resource planning decisions. Operational planning is dependent upon real-time or near-term knowledge of system conditions that include expectations of river flows and runoff, market opportunities, availability of reservoir storage, energy exchanges, and other factors affecting the dynamics of operating a power system. In this loads and resources study, resource availability is compared to an expected level of total retail electricity consumption. The forecasted annual energy electricity retail load plus contract obligations are subtracted from the sum of the projected annual energy capability of existing resources and contract purchases to determine whether BPA and/or the region will be surplus or deficit. Surplus energy is available when resources are greater than loads. This energy could be marketed to increase revenues. Deficits occur when resources are less than loads. Energy deficits could be met by any combination of the following: better-than-critical water conditions, demand-side management and conservation programs, permanent loss of a load (i.e., due to economic conditions or closures), additional contract purchases, and/or new generating resources. The loads and resources analysis in this study simulates the operation of the power system under the Pacific Northwest Coordination Agreement (PNCA). The PNCA defines the planning and operation of seventeen U.S. Pacific Northwest utilities and other parties with generating facilities within the region's hydroelectric (hydro) system. The hydroregulation study used for the 2003 White Book incorporates measures from the National Oceanographic and Atmospheric Administration Fisheries (NOAA Fisheries) Biological Opinion dated December 2000, and the U.S. Fish and Wildlife Service's 2000 Biological Opinion (2000 FCRPS BiOps) for the Snake River and Columbia River projects. These measures include: (1) Increased flow augmentation for juvenile fish migrations in the Snake and Columbia rivers in the spring and summer; (2) Mandatory spill requirements at the Lower Snake and Columbia dams to provide for non-turbine passage routes for juvenile fish migrants; and (3) Additional flows for Kootenai River white sturgeon in the spring. The hydroregulation criteria for this analysis includes: an updated Detailed Operation Plan for Treaty reservoirs for Operating Year (OY) 2004, updated PNCA planning criteria for OY 2003, and revised juvenile fish bypass spill levels for 2000 FCRPS BiOps implementation. The 2003 White Book is presented in two documents: (1) this summary document of Federal system and PNW region loads and resources, and (2) a technical appendix which presents regional loads, grouped by major PNW utility categories, and detailed contract and resource information. The technical appendix is available only in electronic form. Individual customer information regarding marketer contracts is not detailed due to confidentiality agreements. The 2003 White Book analysis updates the December 2002 White Book. This analysis projects the yearly average energy consumption and resource availability

United States. Bonneville Power Administration.

2003-12-01T23:59:59.000Z

480

Control of Wind Turbines for Power Regulation and  

E-Print Network [OSTI]

Control of Wind Turbines for Power Regulation and Load Reduction Juan Jose Garcia Quirante Kongens regulation and load reduction and their ensemble in a variable-speed wind turbine. The power regulation aspects of mathematical modelling of wind turbines, and especially the control methods suited for power

Note: This page contains sample records for the topic "direct control load" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Direct perturbation analysis on cables with concentrated loads P. Yu *, K. Pan  

E-Print Network [OSTI]

cables, overhead transmission lines, etc. The study of vibrations of suspended cables is of great is the galloping of overhead transmission lines which may cause severe disruptions in the electrical supply and even a cas- cading collapse of a line?s supporting towers. * Corresponding author. Tel.: +1

Yu, Pei

482

EXPERIMENTAL TEST FACILITY FOR EVALUATION OF CONTROLS AND CONTROL STRATEGIES  

E-Print Network [OSTI]

Pseudo collector vs Return boiler V2 Direct heating Supplysensors Flow switches Boiler enable I DORIC 220 data loggercollector, consists of a boiler with a controlled mixing

Warren, Mashuri L.

2013-01-01T23:59:59.000Z

483

Effect of dynamic monotonic and cyclic loading on fracture behavior for Japanese carbon steel pipe STS410  

SciTech Connect (OSTI)

The fracture behavior for Japanese carbon steel pipe STS410 was examined under dynamic monotonic and cyclic loading through a research program of International Piping Integrity Research Group (EPIRG-2), in order to evaluate the strength of pipe during the seismic event The tensile test and the fracture toughness test were conducted for base metal and TIG weld metal. Three base metal pipe specimens, 1,500mm in length and 6-inch diameter sch.120, were employed for a quasi-static monotonic, a dynamic monotonic and a dynamic cyclic loading pipe fracture tests. One weld joint pipe specimen was also employed for a dynamic cyclic loading test In the dynamic cyclic loading test, the displacement was controlled as applying the fully reversed load (R=-1). The pipe specimens with a circumferential through-wall crack were subjected four point bending load at 300C in air. Japanese STS410 carbon steel pipe material was found to have high toughness under dynamic loading condition through the CT fracture toughness test. As the results of pipe fracture tests, the maximum moment to pipe fracture under dynamic monotonic and cyclic loading condition, could be estimated by plastic collapse criterion and the effect of dynamic monotonic loading and cyclic loading was a little on the maximum moment to pipe fracture of the STS410 carbon steel pipe. The STS410 carbon steel pipe seemed to be less sensitive to dynamic and cyclic loading effects than the A106Gr.B carbon steel pipe evaluated in IPIRG-1 program.

Kinoshita, Kanji; Murayama, Kouichi; Ogata, Hiroyuki [and others

1997-04-01T23:59:59.000Z

484

Summary of Papers 1. P. Sauer and M. Pai, "Power System SteadyState Stability and the Load Flow Jacobian," IEEE  

E-Print Network [OSTI]

Summary of Papers 1. P. Sauer and M. Pai, "Power System SteadyState Stability and the Load Flow, "The Continuation Power Flow: A Tool for SteadyState Voltage Stability Analysis," IEEE Transactions of the system to maintain adequate and controllable voltage levels at all system load buses. The main concern

McCalley, James D.

485

Modularization and simulation techniques for heat balance-based energy and load calculation  

E-Print Network [OSTI]

the Loads Toolkit research project is to obtain a heat balance based load calculation procedure that

Richard K. Strand

2001-01-01T23:59:59.000Z

486

An investigation of wind loads on conventional and nonconventional highway signs  

E-Print Network [OSTI]

) With the flanged connection at the base of the tubular support the sign could be rotated. in 22. 5-degree increments allowing for a semi-controlled environment. (d) The wind loads on a sign with a single tubular support are believed to be of the same order...AN INVESTIGATION OF WIND LOADS ON CONVENTIONAL AND NONCONVENTIONAL HIGHWAY SIGNS A Thesis By Hayes Ellis Ross, Jr. Submitted to the Graduate College of the Texas A&M University in partial fulfillment of the requirements for the degree...

Ross, Hayes Ellis

1967-01-01T23:59:59.000Z

487

Method and apparatus for imparting strength to a material using sliding loads  

DOE Patents [OSTI]

A method of enhancing the strength of metals by affecting subsurface zones developed during the application of large sliding loads is disclosed. Stresses which develop locally within the near surface zone can be many times larger than those predicted from the applied load and the friction coefficient. These stress concentrations arise from two sources: (1) asperity interactions and (2) local and momentary bonding between the two surfaces. By controlling these parameters more desirable strength characteristics can be developed in weaker metals to provide much greater strength to rival that of steel, for example. 11 figs.

Hughes, D.A.; Dawson, D.B.; Korellis, J.S.

1999-03-16T23:59:59.000Z

488

Method and apparatus for imparting strength to a material using sliding loads  

DOE Patents [OSTI]

A method of enhancing the strength of metals by affecting subsurface zones developed during the application of large sliding loads. Stresses which develop locally within the near surface zone can be many times larger than those predicted from the applied load and the friction coefficient. These stress concentrations arise from two sources: 1) asperity interactions and 2) local and momentary bonding between the two surfaces. By controlling these parameters more desirable strength characteristics can be developed in weaker metals to provide much greater strength to rival that of steel, for example.

Hughes, Darcy Anne (Fremont, CA); Dawson, Daniel B. (Pleasanton, CA); Korellis, John S. (Livermore, CA)

1999-01-01T23:59:59.000Z

489

Method And Apparatus For Imparting Strength To Materials Using Sliding Loads  

DOE Patents [OSTI]

A method of enhancing the strength of metals by affecting subsurface zones developed during the application of large sliding loads. Stresses which develop locally within the near surface zone can be many times larger than those predicted from the applied load and the friction coefficient. These stress concentrations arise from two sources: 1) asperity interactions and 2) local and momentary bonding between the two surfaces. By controlling these parameters more desirable strength characteristics can be developed in weaker metals to provide much greater strength to rival that of steel, for example.

Hughes, Darcy Anne (Fremont, CA); Dawson, Daniel B. (Pleasanton, CA); Korellis, John S. (Livermore, CA)

1999-03-16T23:59:59.000Z

490

Turbine Reliability and Operability Optimization through the use of Direct Detection Lidar Final Technical Report  

SciTech Connect (OSTI)

The goal of this Department of Energy (DOE) project is to increase wind turbine efficiency and reliability with the use of a Light Detection and Ranging (LIDAR) system. The LIDAR provides wind speed and direction data that can be used to help mitigate the fatigue stress on the turbine blades and internal components caused by wind gusts, sub-optimal pointing and reactionary speed or RPM changes. This effort will have a significant impact on the operation and maintenance costs of turbines across the industry. During the course of the project, Michigan Aerospace Corporation (MAC) modified and tested a prototype direct detection wind LIDAR instrument; the resulting LIDAR design considered all aspects of wind turbine LIDAR operation from mounting, assembly, and environmental operating conditions to laser safety. Additionally, in co-operation with our partners, the National Renewable Energy Lab and the Colorado School of Mines, progress was made in LIDAR performance modeling as well as LIDAR feed forward control system modeling and simulation. The results of this investigation showed that using LIDAR measurements to change between baseline and extreme event controllers in a switching architecture can reduce damage equivalent loads on blades and tower, and produce higher mean power output due to fewer overspeed events. This DOE project has led to continued venture capital investment and engagement with leading turbine OEMs, wind farm developers, and wind farm owner/operators.

Johnson, David K; Lewis, Matthew J; Pavlich, Jane C; Wright, Alan D; Johnson, Kathryn E; Pace, Andrew M

2013-02-01T23:59:59.000Z

491

Seismic considerations in the evaluation of temporary loads  

SciTech Connect (OSTI)

Temporary loads in nuclear power facilities can result from a number of activities including special one time operating conditions, repair and upgrade conditions, and ALARA requirements for operation, inspection and maintenance. Many times evaluation of these loadings includes their consideration in conjunction with other design basis loadings such as normal loads and extreme event loads including earthquake loadings. At times this combination with design basis extreme loads, such as earthquake, results in predicted structural demands which exceed the design basis capacity. Many times a major contributor to this demand prediction is the earthquake loadings. Discussed in this paper are analytical methods, probabilistic considerations, and earthquake experienced based evaluations which can be applied to reduce the earthquake demand for short term temporary loadings.

Adams, T.M. [Stevenson and Associates, Cleveland, OH (United States); Stevenson, J.D.

1996-12-01T23:59:59.000Z

492

Directives System Manual  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Manual provides detailed requirements to supplement DOE O 251.1, which establishes requirements for the development, coordination, and sunset review of DOE directives.

1995-10-16T23:59:59.000Z

493

Departmental Directives Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To establish directives as the primary means to set, communicate, and institutionalize policies, requirements, responsibilities, and procedures for Departmental elements and contractors.

2014-10-16T23:59:59.000Z

494

Direct Loan Program (Kentucky)  

Broader source: Energy.gov [DOE]

The Direct Loan Program, is designed to allow businesses to obtain the long term financing needed to encourage growth. The Kentucky Economic Development Finance Authority (KEDFA) may participate...

495

Classified Matter Protection and Control  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

Provides detailed requirements to supplement DOE O 471.2, which establishes policy for the protection and control of classified and unclassified information. Does not cancel other directives.

1995-09-26T23:59:59.000Z

496

Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings  

SciTech Connect (OSTI)

An increasing number of energy efficient appliances operate on direct current (DC) internally, offering the potential to use DC from renewable energy systems directly and avoiding the losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of the direct-DC house with respect to todays typical configuration, assuming identical DC-internal loads. Power draws were modeled for houses in 14 U.S. cities, using hourly, simulated PV-system output and residential loads. The latter were adjusted to reflect a 33% load reduction, representative of the most efficient DC-internal technology, based on an analysis of 32 electricity end-uses. The model tested the effect of climate, electric vehicle (EV) loads, electricity storage, and load shifting on electricity savings; a sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect savings potential. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Based on residential PV penetration projections for year 2035 obtained from the National Energy Modeling System (2.7% for the reference case and 11.2% for the extended policy case), direct-DC could save the nation 10 trillion Btu (without storage) or 40 trillion Btu (with storage). Shifting the cooling load by two hours earlier in the day (pre-cooling) has negligible benefits for energy savings. Direct-DC provides no energy savings benefits for EV charging, to the extent that charging occurs at night. However, if charging occurred during the day, for example with employees charging while at work, the benefits would be large. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly influenced by climate. While direct-DC for residential applications will most likely arise as a spin-off of developments in the commercial sectorbecause of lower barriers to market entry and larger energy benefits resulting from the higher coincidence between load and insolationthis paper demonstrates that there are substantial benefits in the residential sector as well. Among residential applications, space cooling derives the largest energy savings from being delivered by a direct-DC system. It is the largest load for the average residence on a national basis and is particularly so in high-load regions. It is also the load with highest solar coincidence.

Garbesi, Karina; Vossos, Vagelis; Sanstad, Alan; Burch, Gabriel

2011-10-13T23:59:59.000Z

497

Inverse Load Calculation of Wind Turbine Support Structures - A Numerical Verification Using the Comprehensive Simulation Code FAST: Preprint (Revised)  

SciTech Connect (OSTI)

Physically measuring the dynamic responses of wind turbine support structures enables the calculation of the applied loads using an inverse procedure. In this process, inverse means deriving the inputs/forces from the outputs/responses. This paper presents results of a numerical verification of such an inverse load calculation. For this verification, the comprehensive simulation code FAST is used. FAST accounts for the coupled dynamics of wind inflow, aerodynamics, elasticity and turbine controls. Simulations are run using a 5-MW onshore wind turbine model with a tubular tower. Both the applied loads due to the instantaneous wind field and the resulting system responses are known from the simulations. Using the system responses as inputs to the inverse calculation, the applied loads are calculated, which in this case are the rotor thrust forces. These forces are compared to the rotor thrust forces known from the FAST simulations. The results of these comparisons are presented to assess the accuracy of the inverse calculation. To study the influences of turbine controls, load cases in normal operation between cut-in and rated wind speed, near rated wind speed and between rated and cut-out wind speed are chosen. The presented study shows that the inverse load calculation is capable of computing very good estimates of the rotor thrust. The accuracy of the inverse calculation does not depend on the control activity of the wind turbine.

Pahn, T.; Jonkman, J.; Rolges, R.; Robertson, A.

2012-11-01T23:59:59.000Z

498

Evaluation of a Local Air Conditioning Duty Cycling Device as a Load Management Tool  

E-Print Network [OSTI]

the air conditioners were controlled. The local control device and the direct control device were both found to reduce demand of the compressor by about 0.65 kW at 100F ambient temperature. Also, the kW reduction achieved was found to increase with higher...

Schneider, K.; Thedford, M.

1986-01-01T23:59:59.000Z

499

Personalized HVAC control system  

E-Print Network [OSTI]

We present a novel method of building comfort control, focused around the occupant. Custom sensing, communication, and actuation hardware were developed to locate users in a building, and measure various parameters directly ...

Feldmeier, Mark Christopher

500

Methods for Analyzing Electric Load Shape and its Variability  

SciTech Connect (OSTI)

Current methods of summarizing and analyzing electric load shape are discussed briefly and compared. Simple rules of thumb for graphical display of load shapes are suggested. We propose a set of parameters that quantitatively describe the load shape in many buildings. Usi