Sample records for details location fort

  1. Fort Drum integrated resource assessment. Volume 2, Baseline detail

    SciTech Connect (OSTI)

    Dixon, D.R.; Armstrong, P.R.; Brodrick, J.R.; Daellenbach, K.K.; Di Massa, F.V.; Keller, J.M.; Richman, E.E.; Sullivan, G.P.; Wahlstrom, R.R.

    1992-12-01T23:59:59.000Z

    The US Army Forces Command (FORSCOM) has tasked the Pacific Northwest Laboratory (PNL) as the lead laboratory supporting the US Department of Energy (DOE) Federal Energy Management Program`s mission to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Drum. This is a model program PNL is designing for federal customers served by the Niagara Mohawk Power Company. It will identify and evaluate all electric and fossil fuel cost-effective energy projects; develop a schedule at each installation for project acquisition considering project type, size, timing, and capital requirements, as well as energy and dollar savings; and secure 100% of the financing required to implement electric energy efficiency projects from Niagara Mohawk and have Niagara Mohawk procure the necessary contractors to perform detailed audits and install the technologies. This report documents the assessment of baseline energy use at one of Niagara Mohawk`s primary federal facilities, the FORSCOM Fort Drum facility located near Watertown, New York. It is a companion report to Volume 1, the Executive Summary, and Volume 3, the Resource Assessment. This analysis examines the characteristics of electric, gas, oil, propane, coal, and purchased thermal capacity use for fiscal year (FY) 1990. It records energy-use intensities for the facilities at Fort Drum by building type and energy end use. It also breaks down building energy consumption by fuel type, energy end use, and building type. A complete energy consumption reconciliation is presented that includes the accounting of all energy use among buildings, utilities, central systems, and applicable losses.

  2. Fort Stewart integrated resource assessment. Volume 2, Baseline detail

    SciTech Connect (OSTI)

    Keller, J.M.; Sullivan, G.P.; Wahlstrom, R.R.; Larson, L.L.

    1993-08-01T23:59:59.000Z

    This report documents the assessment of baseline energy use at Fort Stewart, a US Army Forces Command facility located near Savannah, Georgia. This is a companion report to Volume 1, Executive Summary, and Volume 3, Integrated Resource Assessment. The US Army Forces Command (FORSCOM) tasked Pacific Northwest Laboratory (PNL) to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Stewart. PNL, in support of the US Department of Energy (DOE) Federal Energy Management Program (FEMP), has designed a model program applicable to the federal sector for this purpose. The model program (1) identifies and evaluates all cost-effective energy projects; (2) develops a schedule at each installation for project acquisition considering project type, size, timing, and capital requirements, as well as energy and dollar savings; and (3) targets 100% of the financing required to implement energy efficiency projects. PNL applied this model program to Fort Stewart. The analysis examines the characteristics of electric, natural gas, oil, propane, and wood chip use for fiscal year (FY) 1990. The results include energy-use intensities for the facilities at Fort Stewart by building type, fuel type, and energy end use. A complete energy consumption reconciliation is presented that accounts for the distribution of all major energy uses and losses among buildings, utilities, and central systems.

  3. Fort Irwin Integrated Resource Assessment. Volume 2, Baseline detail

    SciTech Connect (OSTI)

    Richman, E.E.; Keller, J.M.; Dittmer, A.L.; Hadley, D.L.

    1994-01-01T23:59:59.000Z

    This report documents the assessment of baseline energy use at Fort Irwin, a US Army Forces Command facility near Barstow, California. It is a companion report to Volume 1, Executive Summary, and Volume 3, Integrated Resource Assessment. The US Army Forces Command (FORSCOM) has tasked the US Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory (PNL), to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Irwin. This is part of a model program that PNL has designed to support energy-use decisions in the federal sector. This program (1) identifies and evaluates all cost-effective energy projects; (2) develops a schedule at each installation for project acquisition considering project type, size, timing, and capital requirements, as well as energy and dollar savings; and (3) targets 100% of the financing required to implement energy efficiency projects. PNL applied this model program to Fort Irwin. This analysis examines the characteristics of electric, propane gas, and vehicle fuel use for a typical operating year. It records energy-use intensities for the facilities at Fort Irwin by building type and energy end use. It also breaks down building energy consumption by fuel type, energy end use, and building type. A complete energy consumption reconciliation is presented that accounts for all energy use among buildings, utilities, and applicable losses.

  4. fort hood range revegetation Located on the northern edge of the Texas Hill Country, Fort Hood Military

    E-Print Network [OSTI]

    Conservation Service (NRCS) and Fort Hood's Integrated Training Area Management (ITAM) and Directorate

  5. Water resource opportunity assessment: Fort Dix

    SciTech Connect (OSTI)

    Sullivan, G.P.; Hostick, D.J.; Elliott, D.B.; Fitzpatrick, Q.K.; Dahowski, R.T.; Dison, D.R

    1996-12-01T23:59:59.000Z

    This report provides the results of the water resource opportunity assessments performed by Pacific Northwest National Laboratory at the Fort Dix facility located in Fort Dix, New Jersey.

  6. Fort Drum integrated resource assessment

    SciTech Connect (OSTI)

    Dixon, D.R.; Armstrong, P.R.; Daellenbach, K.K.; Dagle, J.E.; Di Massa, F.V.; Elliott, D.B.; Keller, J.M.; Richman, E.E.; Shankle, S.A.; Sullivan, G.P.; Wahlstrom, R.R.

    1992-12-01T23:59:59.000Z

    The US Army Forces Command (FORSCOM) has tasked Pacific Northwest Laboratory (PNL) as the lead laboratory supporting the US Department of Energy (DOE) Federal Energy Management Program's (FEMP) mission to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Drum. This is a model program PNL is designing for federal customers served by the Niagara Mohawk Power Company (Niagara Mohawk). It will (1) identify and evaluate all electric and fossil fuel cost-effective energy projects; (2) develop a schedule at each installation for project acquisition considering project type, size, timing, capital requirements, as well as energy and dollar savings; and (3) secure 100% of the financing required to implement electric energy efficiency projects from Niagara Mohawk and have Niagara Mohawk procure the necessary contractors to perform detailed audits and install the technologies. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at one of Niagara Mohawk's primary federal facilities, the FORSCOM Fort Drum facility located near Watertown, New York. It is a companion report to Volume 1, the Executive Summary, and Volume 2, the Baseline Detail.

  7. Fort Drum integrated resource assessment

    SciTech Connect (OSTI)

    Dixon, D.R.; Armstrong, P.R.; Brodrick, J.R.; Daellenbach, K.K.; Di Massa, F.V.; Keller, J.M.; Richman, E.E.; Sullivan, G.P.; Wahlstrom, R.R.

    1992-12-01T23:59:59.000Z

    The US Army Forces Command (FORSCOM) has tasked the Pacific Northwest Laboratory (PNL) as the lead laboratory supporting the US Department of Energy (DOE) Federal Energy Management Program's mission to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Drum. This is a model program PNL is designing for federal customers served by the Niagara Mohawk Power Company. It will identify and evaluate all electric and fossil fuel cost-effective energy projects; develop a schedule at each installation for project acquisition considering project type, size, timing, and capital requirements, as well as energy and dollar savings; and secure 100% of the financing required to implement electric energy efficiency projects from Niagara Mohawk and have Niagara Mohawk procure the necessary contractors to perform detailed audits and install the technologies. This report documents the assessment of baseline energy use at one of Niagara Mohawk's primary federal facilities, the FORSCOM Fort Drum facility located near Watertown, New York. It is a companion report to Volume 1, the Executive Summary, and Volume 3, the Resource Assessment. This analysis examines the characteristics of electric, gas, oil, propane, coal, and purchased thermal capacity use for fiscal year (FY) 1990. It records energy-use intensities for the facilities at Fort Drum by building type and energy end use. It also breaks down building energy consumption by fuel type, energy end use, and building type. A complete energy consumption reconciliation is presented that includes the accounting of all energy use among buildings, utilities, central systems, and applicable losses.

  8. Direct-Current Resistivity Survey At Cove Fort Area (Warpinski...

    Open Energy Info (EERE)

    The project at Cove FortSulphurdale in Utah, T26S R67W, is concerned with locating and drilling a 900-meter well to explore the western extension of the Cove Fort-Sulphurdale...

  9. Direct-Current Resistivity Survey At Cove Fort Area - Vapor ...

    Open Energy Info (EERE)

    The project at Cove FortSulphurdale in Utah, T26S R67W, is concerned with locating and drilling a 900-meter well to explore the western extension of the Cove Fort-Sulphurdale...

  10. Evaluation of Location-Specific Predictions by a Detailed Simulation Model of Aedes aegypti Populations

    E-Print Network [OSTI]

    Lloyd, Alun

    specific locations, the cities of Iquitos, Peru, and Buenos Aires, Argentina. These two sites differ that was averaged across all locations. In the Argentina case Skeeter Buster provides a satisfactory simulation from the Research and Policy for Infectious Disease Dynamics (RAPIDD) program of the Science

  11. Fort Carson Sustainability Journey

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    FORT CARSON - ENERGY RELIABILITY AND SECURITY SPIDERS PH2 Microgrid pilot site Power to critical facilities during grid outage Ties several facilities together ...

  12. American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance U.S. Army Project 181 Implementation Challenges in Deployment of an Energy Security Microgrid for Army Reserve Facilities located on the Former Fort Devens Army Base

    SciTech Connect (OSTI)

    Warwick, William M.

    2010-09-30T23:59:59.000Z

    This documents reports on a request for technical assistance from Fort Devens to analyze procurement of energy from nearby renewable generating resources.

  13. Fort Drum integrated resource assessment. Volume 3, Resource assessment

    SciTech Connect (OSTI)

    Dixon, D.R.; Armstrong, P.R.; Daellenbach, K.K.; Dagle, J.E.; Di Massa, F.V.; Elliott, D.B.; Keller, J.M.; Richman, E.E.; Shankle, S.A.; Sullivan, G.P.; Wahlstrom, R.R.

    1992-12-01T23:59:59.000Z

    The US Army Forces Command (FORSCOM) has tasked Pacific Northwest Laboratory (PNL) as the lead laboratory supporting the US Department of Energy (DOE) Federal Energy Management Program`s (FEMP) mission to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Drum. This is a model program PNL is designing for federal customers served by the Niagara Mohawk Power Company (Niagara Mohawk). It will (1) identify and evaluate all electric and fossil fuel cost-effective energy projects; (2) develop a schedule at each installation for project acquisition considering project type, size, timing, capital requirements, as well as energy and dollar savings; and (3) secure 100% of the financing required to implement electric energy efficiency projects from Niagara Mohawk and have Niagara Mohawk procure the necessary contractors to perform detailed audits and install the technologies. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at one of Niagara Mohawk`s primary federal facilities, the FORSCOM Fort Drum facility located near Watertown, New York. It is a companion report to Volume 1, the Executive Summary, and Volume 2, the Baseline Detail.

  14. Fort Stewart integrated resource assessment. Volume 3: Resource assessment

    SciTech Connect (OSTI)

    Sullivan, G.P.; Keller, J.M.; Stucky, D.J.; Wahlstrom, R.R.; Larson, L.L.

    1993-10-01T23:59:59.000Z

    The US Army Forces Command (FORSCOM) has tasked the US Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory, to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Stewart. This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the FORSCOM Fort Stewart facility located approximately 25 miles southwest of Savannah, Georgia. It is a companion report to Volume 1, Executive Summary, and Volume 2, Baseline Detail. The results of the analyses of EROs are presented in 11 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative description of each ERO is provided, along with a table detailing information on the installed cost, energy and dollar savings; impacts on operations and maintenance (O&M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO. The tables also present the results of the life-cycle cost (LCC) analysis indicating the net present value (NPV) and savings to investment ratio (SIR) of each ERO.

  15. FORTE spacecraft vibration mitigation. Final report

    SciTech Connect (OSTI)

    Maly, J.R.

    1996-02-01T23:59:59.000Z

    This report documents work that was performed by CSA Engineering, Inc., for Los Alamos National Laboratory (LANL), to reduce vibrations of the FORTE spacecraft by retrofitting damped structural components into the spacecraft structure. The technical objective of the work was reduction of response at the location of payload components when the structure is subjected to the dynamic loading associated with launch and proto-qualification testing. FORTE is a small satellite that will be placed in orbit in 1996. The structure weighs approximately 425 lb, and is roughly 80 inches high and 40 inches in diameter. It was developed and built by LANL in conjunction with Sandia National Laboratories Albuquerque for the United States Department of Energy. The FORTE primary structure was fabricated primarily with graphite epoxy, using aluminum honeycomb core material for equipment decks and solar panel substrates. Equipment decks were bonded and bolted through aluminum mounting blocks to adjoining structure.

  16. Nebraska Nuclear Profile - Fort Calhoun

    U.S. Energy Information Administration (EIA) Indexed Site

    Fort Calhoun" "Unit","Summer Capacity (MW)","Net Generation (Thousand MWh)","Summer Capacity Factor (Percent)","Type","Commercial Operation Date","License Expiration Date"...

  17. Fort Carson Wind Resource Assessment

    SciTech Connect (OSTI)

    Robichaud, R.

    2012-10-01T23:59:59.000Z

    This report focuses on the wind resource assessment, the estimated energy production of wind turbines, and economic potential of a wind turbine project on a ridge in the southeastern portion of the Fort Carson Army base.

  18. El Paso County Geothermal Project at Fort Bliss

    Broader source: Energy.gov [DOE]

    DOE Geothermal Peer Review 2010 - Presentation. Project objective: Determine if, and where, economically viable low temperature geothermal resources might exist in the McGregor test area ?or if necessary at other lesser known sites that exist on the Fort Bliss Military Reservation ?and to determine at what location they can be best accessed without compromising the tactical and strategic missions of Fort Bliss. Determine if identified resources have adequate temperatures and flow rates/volumes to justify development at any scale, with an eye toward the 20 megawatt target identified. Over base need: 45 megawatts.

  19. Fort Irwin integrated resource assessment. Volume 3: Sitewide Energy Project identification for buildings and facilities

    SciTech Connect (OSTI)

    Keller, J.M.; Dittmer, A.L.; Elliott, D.B.; McMordie, K.L.; Richman, E.E.; Stucky, D.J.; Wahlstrom, R.R.; Hadley, D.L.

    1995-02-01T23:59:59.000Z

    The U.S. Army Forces Command (FORSCOM) has tasked the U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory, to identify, evaluate, and assist in acquiring all cost-effective energy projects at Fort Irwin. This is part of a model program that PNL is designing to support energy-use decisions in the federal sector. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the FORSCOM Fort Irwin facility located near Barstow, California. It is a companion report to Volume 1, Executive Summary, and Volume 2, Baseline Detail. The results of the analyses of EROs are presented in 16 common energy end-use categories (e.g., boilers and furnaces, service hot water, and building lighting). A narrative description of each ERO is provided, along with a table detailing information on the installed cost, energy and dollar savings; impacts on operations and maintenance (O&M); and, when applicable, a discussion of energy supply and demand, energy security, and environmental issues. A description of the evaluation methodologies and technical and cost assumptions is also provided for each ERO. Summary tables present the cost-effectiveness of energy end-use equipment before and after the implementation of each ERO and present the results of the life-cycle cost (LCC) analysis indicating the net present valve (NPV) and savings-to-investment ratio (SIR) of each ERO.

  20. Fort Stewart integrated resource assessment. Volume 1, Executive summary

    SciTech Connect (OSTI)

    Larson, L.L.; Keller, J.M.

    1993-10-01T23:59:59.000Z

    The US Department of Energy (DOE) Federal Energy Management Program (FEMP), supported by the Pacific Northwest Laboratory (PNL), has developed a model program that provides a systematic approach to evaluating energy opportunities that (1) identifies the building groups and end uses that use the most energy (not just have the greatest energy-use intensity), and (2) evaluates the numerous options for retrofit or installation of new technology that will result in the selection of the most cost-effective technologies. In essence, this model program provides the federal energy manager with a roadmap to significantly reduce energy use in a planned, rational, cost-effective fashion that is not biased by the constraints of the typical funding sources available to federal sites. The results from this assessment process can easily be turned into a five- to ten-year energy management plan that identifies where to start and how to proceed in order to reach the mandated energy consumption targets. This report provides the results of the fossil fuel and electric energy resource opportunity (ERO) assessments performed by PNL at the US Army US Forces Command (FORSCOM) Fort Stewart facility located approximately 25 miles southwest of Savannah, Georgia. It is a companion report to Volume 2, Baseline Detail, and Volume 3, Resource Assessment.

  1. FORT UNION DEEP

    SciTech Connect (OSTI)

    Lyle A. Johnson Jr.

    2002-03-01T23:59:59.000Z

    Coalbed methane (CBM) is currently the hottest area of energy development in the Rocky Mountain area. The Powder River Basin (PRB) is the largest CBM area in Wyoming and has attracted the majority of the attention because of its high permeability and relatively shallow depth. Other Wyoming coal regions are also being targeted for development, but most of these areas have lower permeability and deeper coal seams. This project consists of the development of a CBM stimulation system for deep coal resources and involves three work areas: (1) Well Placement, (2) Well Stimulation, and (3) Production Monitoring and Evaluation. The focus of this project is the Washakie Basin. Timberline Energy, Inc., the cosponsor, has a project area in southern Carbon County, Wyoming, and northern Moffat County, Colorado. The target coal is found near the top of the lower Fort Union formation. The well for this project, Evans No.1, was drilled to a depth of 2,700 ft. Three coal seams were encountered with sandstone and some interbedded shale between seams. Well logs indicated that the coal seams and the sandstone contained gas. For the testing, the upper seam at 2,000 ft was selected. The well, drilled and completed for this project, produced very little water and only occasional burps of methane. To enhance the well, a mild severity fracture was conducted to fracture the coal seam and not the adjacent sandstone. Fracturing data indicated a fracture half-length of 34 ft, a coal permeability of 0.2226 md, and permeability of 15.3 md. Following fracturing, the gas production rate stabilized at 10 Mscf/day within water production of 18 bpd. The Western Research Institute (WRI) CBM model was used to design a 14-day stimulation cycle followed by a 30-day production period. A maximum injection pressure of 1,200 psig to remain well below the fracture pressure was selected. Model predictions were 20 Mscf/day of air injection for 14 days, a one-day shut-in, then flowback. The predicted flowback was a four-fold increase over the prestimulation rate with production essentially returning to prestimulation rates after 30 days. The physical stimulation was conducted over a 14-day period. Problems with the stimulation injection resulted in a coal bed fire that was quickly quenched when production was resumed. The poststimulation, stabilized production was three to four times the prestimulation rate. The methane content was approximately 45% after one day and increased to 65% at the end of 30 days. The gas production rate was still two and one-half times the prestimulation rate at the end of the 30-day test period. The field results were a good match to the numerical simulator predictions. The physical stimulation did increase the production, but did not produce a commercial rate.

  2. FORT UNION DEEP

    SciTech Connect (OSTI)

    Lyle A. Johnson Jr.

    2002-09-01T23:59:59.000Z

    Coalbed methane (CBM) is currently the hottest area of energy development in the Rocky Mountain area. The Powder River Basin (PRB) is the largest CBM area in Wyoming and has attracted the majority of the attention because of its high permeability and relatively shallow depth. Other Wyoming coal regions are also being targeted for development, but most of these areas have lower permeability and deeper coal seams. This project consists of the development of a CBM stimulation system for deep coal resources and involves three work areas: (1) Well Placement, (2) Well Stimulation, and (3) Production Monitoring and Evaluation. The focus of this project is the Washakie Basin. Timberline Energy, Inc., the cosponsor, has a project area in southern Carbon County, Wyoming, and northern Moffat County, Colorado. The target coal is found near the top of the lower Fort Union formation. The well for this project, Evans No.1, was drilled to a depth of 2,700 ft. Three coal seams were encountered with sandstone and some interbedded shale between seams. Well logs indicated that the coal seams and the sandstone contained gas. For the testing, the upper seam at 2,000 ft was selected. The well, drilled and completed for this project, produced very little water and only occasional burps of methane. To enhance the well, a mild severity fracture was conducted to fracture the coal seam and not the adjacent sandstone. Fracturing data indicated a fracture half-length of 34 ft, a coal permeability of 0.2226 md, and permeability of 15.3 md. Following fracturing, the gas production rate stabilized at 10 Mscf/day within water production of 18 bpd. The Western Research Institute (WRI) CBM model was used to design a 14-day stimulation cycle followed by a 30-day production period. A maximum injection pressure of 1,200 psig to remain well below the fracture pressure was selected. Model predictions were 20 Mscf/day of air injection for 14 days, a one-day shut-in, then flowback. The predicted flowback was a four-fold increase over the prestimulation rate with production essentially returning to prestimulation rates after 30 days. The physical stimulation was conducted over a 14-day period. Problems with the stimulation injection resulted in a coal bed fire that was quickly quenched when production was resumed. The poststimulation, stabilized production was three to four times the prestimulation rate. The methane content was approximately 45% after one day and increased to 65% at the end of 30 days. The gas production rate was still two and one-half times the prestimulation rate at the end of the 30-day test period. The field results were a good match to the numerical simulator predictions. The physical stimulation did increase the production, but did not produce a commercial rate.

  3. Nebraska Nuclear Profile - Fort Calhoun

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5 Tables July 1996 Energy Information Administration Office ofthrough 1996) in DelawareTotal Consumption (MillionYeartotalFort

  4. Informal report on measurements of slant TEC by FORTE

    SciTech Connect (OSTI)

    Massey, R.S.

    1997-11-21T23:59:59.000Z

    Los Alamos National Laboratory`s Space and Atmospheric Sciences group is now operating the FORTE satellite, which has two sets of instruments: optical detectors and radio detectors. In this report the author describes work with one set of radio detectors that allow measurements of the total electron content (TEC) traversed by VHF radiation originating at an electromagnetic pulse (EMP) generator located at Los Alamos.

  5. Wind Monitoring Report for Fort Wainwright's Donnelly Training Area

    SciTech Connect (OSTI)

    Orrell, Alice C.; Dixon, Douglas R.

    2011-01-18T23:59:59.000Z

    Using the wind data collected at a location in Fort Wainwright’s Donnelly Training Area (DTA) near the Cold Regions Test Center (CRTC) test track, Pacific Northwest National Laboratory (PNNL) estimated the gross and net energy productions that proposed turbine models would have produced exposed to the wind resource measured at the meteorological tower (met tower) location during the year of measurement. Calculations are based on the proposed turbine models’ standard atmospheric conditions power curves, the annual average wind speeds, wind shear estimates, and standard industry assumptions.

  6. United States Army; Fort Gordon, Georgia, Range Control Operations

    Office of Environmental Management (EM)

    (DPTMS), Page 10 2.5 Chief-Training Division, DPTMS, Page 10 2.6 Fort Gordon Range Control Operations, Page 10 2.7 Fort Gordon Installation Range Manager, Page 10 2.8 Fort...

  7. EECBG Success Story: Bright Green Spot: Fort Worth Library |...

    Broader source: Energy.gov (indexed) [DOE]

    Bright Green Spot: Fort Worth Library EECBG Success Story: Bright Green Spot: Fort Worth Library September 30, 2010 - 9:53am Addthis Fort Worth's Central Library is seeing...

  8. Bright Green Spot: Fort Worth Library | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    Bright Green Spot: Fort Worth Library Bright Green Spot: Fort Worth Library September 30, 2010 - 4:07pm Addthis Lindsay Gsell Fort Worth's Central Library is seeing tremendous...

  9. Energy Department Recognizes Fort Worth for Leadership in Advancing...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Fort Worth for Leadership in Advancing Energy Efficiency Energy Department Recognizes Fort Worth for Leadership in Advancing Energy Efficiency April 14, 2015 - 10:04am Addthis NEWS...

  10. City of Fort Collins Comment on Information Collection Extension...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    2011 City of Fort Collins Comment on Information Collection Extension, October 2011 The City of Fort Collins provided comments to the Department of Energy's notice of intent to...

  11. Fort Loudoun Electric Coop | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJumpGermanFife Energy ParkForked Deer ElectricFort BelknapFortFort

  12. Fort Valley Utility Comm | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJumpGermanFife Energy ParkForked Deer ElectricFortFort PierceFort

  13. Renewable Energy Opportunities at Fort Hood, Texas

    SciTech Connect (OSTI)

    Solana, Amy E.; Warwick, William M.; Orrell, Alice C.; Russo, Bryan J.; Parker, Kyle R.; Weimar, Mark R.; Horner, Jacob A.; Manning, Anathea

    2011-11-14T23:59:59.000Z

    This report presents the results of Pacific Northwest National Laboratory's (PNNL) follow-on renewable energy (RE) assessment of Fort Hood. Fort Hood receives many solicitations from renewable energy vendors who are interested in doing projects on site. Based on specific requests from Fort Hood staff so they can better understand these proposals, and the results of PNNL's 2008 RE assessment of Fort Hood, the following resources were examined in this assessment: (1) Municipal solid waste (MSW) for waste-to-energy (WTE); (2) Wind; (3) Landfill gas; (4) Solar photovoltaics (PV); and (5) Shale gas. This report also examines the regulatory issues, development options, and environmental impacts for the promising RE resources, and includes a review of the RE market in Texas.

  14. Fort Collins Utilities- Home Efficiency Program

    Broader source: Energy.gov [DOE]

    Fort Collins Utilities (FCU) provides rebates for customers living in existing single-family homes who pursue energy efficiency projects. Either the Efficiency Audit or Efficiency Audit Plus is a...

  15. EA-1922: Combined Power and Biomass Heating System, Fort Yukon, Alaska

    Broader source: Energy.gov [DOE]

    DOE (lead agency), Denali Commission (cooperating agency) and USDA Rural Utilities Services (cooperating agency) are proposing to provide funding to support the final design and construction of a biomass combined heat and power plant and associated district heating system to the Council of Athabascan Tribal Governments and the Gwitchyaa Zhee Corporation. The proposed biomass district heating system would be located in Fort Yukon Alaska.

  16. Dust Plume Modeling at Fort Bliss: Move-Out Operations, Combat Training and Wind Erosion

    SciTech Connect (OSTI)

    Chapman, Elaine G.; Rishel, Jeremy P.; Rutz, Frederick C.; Seiple, Timothy E.; Newsom, Rob K.; Allwine, K Jerry

    2006-09-29T23:59:59.000Z

    The potential for air-quality impacts from heavy mechanized vehicles operating in the training ranges and on the unpaved main supply routes at Fort Bliss was investigated. This report details efforts by the staff of Pacific Northwest National Laboratory for the Fort Bliss Directorate of Environment in this investigation. Dust emission and dispersion from typical activities, including move outs and combat training, occurring on the installation were simulated using the atmospheric modeling system DUSTRAN. Major assumptions associated with designing specific modeling scenarios are summarized, and results from the simulations are presented.

  17. Renewable Energy Opportunities at Fort Sill, Oklahoma

    SciTech Connect (OSTI)

    Boyd, Brian K.; Hand, James R.; Horner, Jacob A.; Orrell, Alice C.; Russo, Bryan J.; Weimar, Mark R.; Nesse, Ronald J.

    2011-03-31T23:59:59.000Z

    This document provides an overview of renewable resource potential at Fort Sill, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations. This effort focuses on grid-connected generation of electricity from renewable energy sources and on ground source heat pumps for heating and cooling buildings. The effort was funded by the U.S. Army Installation Management Command (IMCOM) as follow-on to the 2005 Department of Defense (DoD) Renewables Assessment. The site visit to Fort Sill took place on June 10, 2010.

  18. Renewable Energy Opportunities at Fort Polk, Louisiana

    SciTech Connect (OSTI)

    Solana, Amy E.; Boyd, Brian K.; Horner, Jacob A.; Gorrissen, Willy J.; Orrell, Alice C.; Weimar, Mark R.; Hand, James R.; Russo, Bryan J.; Williamson, Jennifer L.

    2010-11-17T23:59:59.000Z

    This document provides an overview of renewable resource potential at Fort Polk, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations. This effort focuses on grid-connected generation of electricity from renewable energy sources and also on ground source heat pumps for heating and cooling buildings. The effort was funded by the U.S. Army Installation Management Command (IMCOM) as follow-on to the 2005 Department of Defense (DoD) Renewables Assessment. The site visit to Fort Polk took place on February 16, 2010.

  19. Fort Bliss Geothermal Area | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJumpGermanFife Energy ParkForked Deer ElectricFort BelknapFort

  20. Fort Pierce Utilities Auth | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJumpGermanFife Energy ParkForked Deer ElectricFortFort Pierce

  1. Strategic Energy Management Plan For Fort Buchanan, Puerto Rico

    SciTech Connect (OSTI)

    Parker, Steven A.; Hunt, W. D.

    2001-10-31T23:59:59.000Z

    This document reports findings and recommendations as a result of a design assistance project with Fort Buchanan with the goals of developing a Strategic Energy Management Plan for the Site. A strategy has been developed with three major elements in mind: 1) development of a strong foundation from which to build, 2) understanding technologies that are available, and 3) exploring financing options to fund the implementation of improvements. The objective of this report is to outline a strategy that can be used by Fort Buchanan to further establish an effective energy management program. Once a strategy is accepted, the next step is to take action. Some of the strategies defined in this Plan may be implemented directly. Other strategies may require the development of a more sophisticated tactical, or operational, plan to detail a roadmap that will lead to successful realization of the goal. Similarly, some strategies are not single events. Rather, some strategies will require continuous efforts to maintain diligence or to change the culture of the Base occupants and their efforts to conserve energy resources.

  2. Fort Pierce Utilities Authority- Solar Water Heating Rebate

    Broader source: Energy.gov [DOE]

    Note: Fort Pierce Utilities Authority has completed its rebate program for 2015. Check the website for updates.

  3. Solar Energy Development Assistance for Fort Hunter Liggett

    SciTech Connect (OSTI)

    Russo, Bryan J.; Hoffman, Michael G.; Chvala, William D.

    2011-03-30T23:59:59.000Z

    Pacific Northwest National Laboratory provided assistance to Fort Hunter Liggett to determine the opportunities for solar energy development on the site. Increasing use of renewable energy is mandated by several executive orders and legislation. Fort Hunter Liggett has many attributes that enhance its suitability for renewable energy development. First, the site is located south of San Francisco in a remote portion of the costal foothills. Brush and forest fires are frequent and often result in power outages, which subsequently impacts the site’s training mission. In addition, the site’s blended electric rate during fiscal year (FY) 2010 was high at 12 ˘/kWh. Lastly, the solar resource is moderately high; the site receives nearly 5.7 kWh/m2/day on a south facing, latitude-tilted surface. In light of these factors, the site is a clear candidate for a solar photovoltaic array. Prior to Pacific Northwest National Laboratory’s (PNNL) involvement, the site secured funding for a 1 megawatt (MW) photovoltaic (PV) array that will also provide shading for site vehicles. To best implement this project, PNNL conducted a site visit and was tasked with providing the site technical guidance and support regarding module selection, array siting, and other ancillary issues.

  4. 1490 Campus Delivery Fort Collins, Colorado 80523-1490

    E-Print Network [OSTI]

    or coauthored over 100 articles for various journals and publications. In his spare time, Dr. Allen is an active he discusses the efforts being made to document the flora of Fort Polk, and by publishing articles concerning the flora of Fort Polk in academic journals each year. His work at Fort Polk has given

  5. Process Optimization Assessments at Fort Leonard Wood, Missouri and Fort Carson, Colorado

    E-Print Network [OSTI]

    Lin, M.; Vavrin, J.; Smith, W.

    2004-01-01T23:59:59.000Z

    Process Optimization Assessments at Fort Leonard Wood, Missouri and Fort Carson, Colorado Mike C.J. Lin U.S. Army Corps of Engineers Engineer Research Development Center, Construction Engineering Research Laboratory Champaign, Illinois... a specific Level II scope of work, respective roles, and the most expeditious path forward. This begins with a formal review of this report, combined with a planning session to organize the Level II program. REFERENCES 1. Lin, Mike C.J., et...

  6. Relative risk site evaluation for buildings 7740 and 7741 Fort Campbell, Kentucky

    SciTech Connect (OSTI)

    Last, G.V.; Gilmore, T.J.; Bronson, F.J.

    1998-01-01T23:59:59.000Z

    Buildings 7740 and 7741 are a part of a former nuclear weapon`s storage and maintenance facility located in the southeastern portion of Fort Campbell, Kentucky. This underground tunnel complex was originally used as a classified storage area beginning in 1949 and continuing until 1969. Staff from the Pacific Northwest National Laboratory recently completed a detailed Relative Risk Site Evaluation of the facility. This evaluation included (1) obtaining engineering drawings of the facility and associated structures, (2) conducting detailed radiological surveys, (3) air sampling, (4) sampling drainage systems, and (5) sampling the underground wastewater storage tank. Ten samples were submitted for laboratory analysis of radionuclides and priority pollutant metals, and two samples submitted for analysis of volatile organic compounds. No volatile organic contaminants were detected using field instruments or laboratory analyses. However, several radionuclides and metals were detected in water and/or soil/sediment samples collected from this facility. Of the radionuclides detected, only {sup 226}Ra may have come from facility operations; however, its concentration is at least one order of magnitude below the relative-risk comparison value. Several metals (arsenic, beryllium, cadmium, copper, mercury, lead, and antimony) were found to exceed the relative-risk comparison values for water, while only arsenic, cadmium, and lead were found to exceed the relative risk comparison values for soil. Of these constituents, it is believed that only arsenic, beryllium, mercury, and lead may have come from facility operations. Other significant hazards posed by the tunnel complex include radon exposure and potentially low oxygen concentrations (<19.5% in atmosphere) if the tunnel complex is not allowed to vent to the outside air. Asbestos-wrapped pipes, lead-based paint, rat poison, and possibly a selenium rectifier are also present within the tunnel complex.

  7. Fort Benning Indianhead Townhome Renovations

    SciTech Connect (OSTI)

    Stephenson, R.; Roberts, S.; Butler, T.; Kim, E.

    2012-12-01T23:59:59.000Z

    The NAHB Research Center partnered with production builder Winchester/Camberley Homes to build a DOE Building America New Construction Test House (NCTH). This single family, detached house, located in the mixed-humid climate zone of Silver Spring, MD, was completed in June 2011. The primary goal for this house was to improve energy efficiency by 30% over the Building America B10 benchmark by developing and implementing an optimized energy solutions package design that could be cost effectively and reliably constructed on a production basis using quality management practices. The intent of this report is to outline the features of this house, discuss the implementation of the energy efficient design, and report on short-term testing results. During the interactive design process of this project, numerous iterations of the framing, air sealing, insulation, and space conditioning systems were evaluated for energy performance, cost, and practical implementation. The final design featured numerous advanced framing techniques, high levels of insulation, and the HVAC system entirely within conditioned space. Short-term testing confirmed a very tight thermal envelope and efficient and effective heating and cooling. In addition, relevant heating, cooling, humidity, energy, and wall cavity moisture data will be collected and presented in a future long-term report.

  8. Renewable Energy Opportunities at Fort Hood, Texas

    SciTech Connect (OSTI)

    Chvala, William D.; Warwick, William M.; Dixon, Douglas R.; Solana, Amy E.; Weimar, Mark R.; States, Jennifer C.; Reilly, Raymond W.

    2008-06-30T23:59:59.000Z

    The document provides an overview of renewable resource potential at Fort Hood based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations. The effort was funded by the U.S. Army Installation Management Command (IMCOM) as follow-on to the 2005 DoD Renewables Assessment. This effort focuses on grid-connected generation of electricity from renewable energy sources and also ground source heat pumps for heating and cooling buildings, as directed by IMCOM.

  9. Dust Plume Modeling from Ranges and Maneuver Areas on Fort Bliss and the White Sands Missile Range: Final Report

    SciTech Connect (OSTI)

    Chapman, Elaine G.; Barnard, James C.; Rutz, Frederick C.; Pekour, Mikhail S.; Rishel, Jeremy P.; Shaw, William J.

    2009-05-04T23:59:59.000Z

    The potential for air quality impacts from heavy mechanized vehicles operating on and between the unpaved main supply routes at Fort Bliss and White Sands Missile Range was investigated. This report details efforts by the staff of Pacific Northwest National Laboratory for the Fort Bliss Directorate of Environment in this investigation. Dust emission and dispersion from typical move-out activities occurring on the installations were simulated using the atmospheric modeling system DUSTRAN. Major assumptions associated with designing the modeling scenarios are summarized and results of simulations conducted under these assumptions are presented for four representative meteorological periods.

  10. Process Optimization Assessments at Fort Leonard Wood, Missouri and Fort Carson, Colorado 

    E-Print Network [OSTI]

    Lin, M.; Vavrin, J.; Smith, W.

    2004-01-01T23:59:59.000Z

    for process energy efficiency improvements and reductions of pollutant emissions at Fort Leonard Wood and Fort Carson, using the process energy and pollution reduction (PEPR) methodology and the process optimization guide, both of which are tools developed.../CERL Technical Report, TR- 03-8, April 2003. 3. Lin, Mike C.J., et al. "Process Energy and Pollution Reduction (PEPR) Level I Review at the Watervliet Arsenal, New York" USACERL Technical Report 99/92, November 1999. 4. Lin, Mike C.J., Walter Smith...

  11. Fort Boise Veteran's Hospital District Heating Low Temperature...

    Open Energy Info (EERE)

    Veteran's Hospital District Heating Low Temperature Geothermal Facility Jump to: navigation, search Name Fort Boise Veteran's Hospital District Heating Low Temperature Geothermal...

  12. Contrasting Eruption Styles Of The 147 Kimberlite, Fort A La...

    Open Energy Info (EERE)

    Contrasting Eruption Styles Of The 147 Kimberlite, Fort A La Corne, Saskatchewan, Canada Jump to: navigation, search OpenEI Reference LibraryAdd to library Journal Article:...

  13. acid pit fort: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    at DallasFort Worth International Airport Jerry R. Dennis, CEM, CEP Energy Manager October 9, 2013 Energy Management Practices at DFW Airport, October 9, 2013 Presentation...

  14. Fort Pierce Utilities Authority- Solar Water Heating Rebate (Florida)

    Broader source: Energy.gov [DOE]

    '''''Fort Pierce Utilities Authority has suspended the Solar Water Heating rebate program until 2013. Contact the utility for more information on these offerings.'''''

  15. Fort Totten Wind Farm | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489Information HydroFontana,dataset nameFort BendLupton,Totten

  16. FORTE antenna element and release mechanism design

    SciTech Connect (OSTI)

    Rohweller, D.J. [Astro Aerospace Corp., Carpinteria, CA (United States); Butler, T.Af. [Los Alamos National Lab., NM (United States)

    1995-02-01T23:59:59.000Z

    The Fast On-Orbit Recording of Transient Events (FORTE) satellite being built by Los Alamos National Laboratory (LANL) and Sandia National Laboratories (SNL) has as its most prominent feature a large deployable (11 m by 5 m) log periodic antenna to monitor emissions from electrical storms on the Earth. This paper describes the antenna and the design for the long elements and explains the dynamics of their deployment and the damping system employed. It also describes the unique paraffin-actuated reusable tie-down and release mechanism employed in the system.

  17. Fort Payne Improvement Auth | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJumpGermanFife Energy ParkForked Deer ElectricFort

  18. Fort Bliss Geothermal Area | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are8COaBulkTransmissionSitingProcess.pdf Jump to:ar-80m.pdfFillmoreGabbs ValleyCity,ForkedAdd aNorthFort Bliss

  19. SPIDERS Phase 2 Fort Carson Technology Transition Consolidated Report

    Broader source: Energy.gov [DOE]

    Final program public report for phase 2 summarizes the key outcomes generated during the second phase of the Smart Power Infrastructure Demonstration for Energy Reliability and Security (SPIDERS) Joint Capability Technology Demonstration (JCTD), which was implemented at Fort Carson, Colorado, during 2013-2014. The public demonstration of the technology at Fort Carson was completed in April 2014.

  20. Targeting Net Zero Energy at Fort Carson: Assessment and Recommendations

    SciTech Connect (OSTI)

    Anderson, K.; Markel, T.; Simpson, M.; Leahey, J.; Rockenbaugh, C.; Lisell, L.; Burman, K.; Singer, M.

    2011-10-01T23:59:59.000Z

    The U.S. Army's Fort Carson installation was selected to serve as a prototype for net zero energy assessment and planning. NREL performed the comprehensive assessment to appraise the potential of Fort Carson to achieve net zero energy status through energy efficiency, renewable energy, and electric vehicle integration. This report summarizes the results of the assessment and provides energy recommendations. This study is part of a larger cross-laboratory effort that also includes an assessment of renewable opportunities at seven other DoD Front Range installations, a microgrid design for Fort Carson critical loads and an assessment of regulatory and market-based barriers to a regional secure smart grid.

  1. U.S. Army Fort Carson Photovoltaics Project Lease

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    NO. DACA45-1-07-6037 DEPARTMENT OF THE ARMY LEASE FORT CARSON MILITARY INSTALLATION EL PAS0 COUNTY, COLORADO THIS LEASE, made on behalf of the United States, between the SECRETARY...

  2. U.S. Army Fort Carson Environmental Document

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    1.0 PURPOSE The purpose of this Finding of Suitability to Lease (FOSL) is to document the environmental suitability of property at Fort Carson, Colorado, for leasing and...

  3. Fort Pierce Utilities Authority- Residential Energy Efficiency Rebate Program

    Broader source: Energy.gov [DOE]

    Fort Pierce Utilities Authority offers a variety of incentives for their residential customers to save energy in their homes. Rebates are available for room A/C units, insulation upgrades, central...

  4. area fort calhoun: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    the laundry operation and the DOL maintenance complex with specific focus on paintingmedia blasting... Lin, M.; Vavrin, J.; Smith, W. 2004-01-01 33 FOREST TECHNOLOGY 2 FORT...

  5. Paleoenvironment of Fort Union Formation, South Dakota

    SciTech Connect (OSTI)

    Goodrum, C.

    1983-08-01T23:59:59.000Z

    Rocks of Paleocene age are represented in the Cave Hills of northwestern South Dakota by the Ludlow, Cannonball, and Tongue River members of the Fort Union Formation. The Cave Hills are situated within the southern margin of the Williston basin, 80 mi (130 km) north of the Black Hills, South Dakota. Numerous fine-grained, fining-upward sedimentary sequences comprise the Ludlow Member and are attributed to meandering streams occupying a low-gradient lower alluvial to upper deltaic plain. The Cannonball Member is 130 ft (40 m) thick in the North Cave Hills and is represented by two fine-grained, coarsening-upward sandstone mudstone sequences. A distinct vertical succession of sedimentary facies occur within each sequence representing offshore/lower shoreface through upper shoreface/foreshore depositional environment. A north to northeast depositional strike for the Cannonball shoreline is inferred from ripple crest and cross-bed orientations. The basal part of the Tongue River consists of approximately 40 to 50 ft (12 to 15 m) of lenticular sandstone, siltstone, mudstone, thin-bedded lignite, and kaolinite beds representing thin broad channels, point-bar, levee, overbank, and nearshore swamp depositional environments. Massive fluvial channel sandstones measuring several tens of ft in thickness overlie the fine-grained basal Tongue River lithologies. These channel sandstones represent the continued progradation of continental/fluvial/coastal plain depositional environments eastward over the marine sandstones of the Cannonball Member.

  6. Four years of operations and results with FORTE

    SciTech Connect (OSTI)

    Klingner, P. L. (Phillip L.); Carlson, L. D. (Leslie D.); Dingler, R. D. (Robert D.); Esch-Mosher, D. M. (Diana M.); Jacobson, A. R.; Roussel-Dupre, D. (Diane)

    2001-01-01T23:59:59.000Z

    The FORTE (Fast Onboard Recording of Transient Events) satellite was launched on 29 August 1997 and has been in continuous operation since that time. FORTE was placed in a nearly circular, 825-km-altitude, 70 degrees inclination orbit by a Pegasus rocket funded by Air Force Space Test Program. The Department of Energy funded the FORTE satellite, which was designed and built at Los Alamos. FORTE's successful launch and engineered robustness were a result of several years of dedicated work by the joint Los Alamos National Laboratory/Sandia National Laboratory project team, led through mission definition, payload and satellite development, and launch by Dr. Stephen Knox. The project is now led by Dr. Abram Jacobson. FORTE carries a suite of instruments, an optical system and a rf system, for the study of lightning and anthropogenic signals. As a result of this effort, new understandings of lightning events have emerged as well as a more complete understanding of the relationship between optical and rf lightning events. This paper will provide an overview of the FORTE satellite and will discuss the on orbit performance of the subsystems.

  7. Central Energy System Modernization at Fort Jackson, South Carolina

    SciTech Connect (OSTI)

    Brown, Daryl R.; Chvala, William D.; Dirks, James A.

    2006-11-29T23:59:59.000Z

    An evaluation of technology options was conducted for the central energy systems at Fort Jackson, South Carolina. There were two objectives in conducting this study. From a broader viewpoint, the Army would like to develop a systematic approach to management of its central energy systems and selected Fort Jackson for this ''pilot'' study for a prospective Central Energy System Modernization Program. From a site-specific perspective, the objective was to identify the lowest life-cycle cost energy supply option(s) at Fort Jackson for buildings currently served by central boilers and chillers. This study was co-funded by the Army's Southeast Region and the U.S. Department of Energy's Federal Energy Management Program.

  8. Renewable Energy Opportunities at Fort Campbell, Tennessee/Kentucky

    SciTech Connect (OSTI)

    Hand, James R.; Horner, Jacob A.; Kora, Angela R.; Orrell, Alice C.; Russo, Bryan J.; Weimar, Mark R.; Nesse, Ronald J.

    2011-03-31T23:59:59.000Z

    This document provides an overview of renewable resource potential at Fort Campbell, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations. This effort focuses on grid-connected generation of electricity from renewable energy sources and also on ground source heat pumps for heating and cooling buildings. The effort was funded by the U.S. Army Installation Management Command (IMCOM) as follow-on to the 2005 Department of Defense (DoD) Renewables Assessment. The site visit to Fort Campbell took place on June 10, 2010.

  9. Renewable Energy Opportunities at Fort Drum, New York

    SciTech Connect (OSTI)

    Brown, Scott A.; Orrell, Alice C.; Solana, Amy E.; Williamson, Jennifer L.; Hand, James R.; Russo, Bryan J.; Weimar, Mark R.; Rowley, Steven; Nesse, Ronald J.

    2010-10-20T23:59:59.000Z

    This document provides an overview of renewable resource potential at Fort Drum, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations. This effort focuses on grid-connected generation of electricity from renewable energy sources and also on ground source heat pumps for heating and cooling buildings. The effort was funded by the U.S. Army Installation Management Command (IMCOM) as follow-on to the 2005 Department of Defense (DoD) Renewables Assessment. The site visit to Fort Drum took place on May 4 and 5, 2010.

  10. Fort Inge and the Texas frontier, 1849-1869

    E-Print Network [OSTI]

    Smith, Thomas Tyree

    1991-01-01T23:59:59.000Z

    ) May 1991 ABSTRACT Fort Inge and the Texas Frontier, 1849-1869. (May 1991) Thomas Tyree Smith B. S. in Ed. , Southwest Texas State University Chair of Advisory Committee: Dr. Joseph G. Dawson III Now an obscure site near Uvalde, Fort Inge was once...'s Report on the Eighth Nilitary Department, " Cartographic Division, DR 148, RG 77, NA. 12 NOTES 1. Frederick Law Olmsted, A Journey Through Texas: Or A Saddle- Trip On the Southwestern Frontier (New York: Dix, Edwards 6 Co. , 1857; rpr. , Austin...

  11. Fort Worth, Texas: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJumpGermanFife Energy ParkForked Deer ElectricFortFort

  12. Conference shapes direction of Doctrine 2015 -Fort Leavenworth, KS -The Fort Leavenworth Lamp http://www.ftleavenworthlamp.com/news/around_the_force/x27456959/Conference-shapes-direction-of-Doctrine-2015[8/18/2011 12:32:27 PM

    E-Print Network [OSTI]

    US Army Corps of Engineers

    Conference shapes direction of Doctrine 2015 - Fort Leavenworth, KS - The Fort Leavenworth Lamp and more accessible. The conference was led by the Combined Arms Doctrine Directorate, a subordinate

  13. Better Buildings Challenge U.S. Department of Energy Fort Worth 

    E-Print Network [OSTI]

    Roskelly,A.; LEED aP BD+C; GGP; GPCP USGBC Representative

    2014-01-01T23:59:59.000Z

    Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 The Fort Worth Better Buildings Challenge 3 ? Community Partner Agreement (2012) ? Focus: Energy and Water Reductions ? Structure: Local Partner & Ally Network ? Partners: Building Property... • ASHRAE Fort Worth • North Texas AEE • AIA Fort Worth • USGBC north Texas • Oncor Electric Delivery • Atmos Energy • FW Water Department ESL-KT-14-11-33 CATEE 2014: Clean Air Through Efficiency Conference, Dallas, Texas Nov. 18-20 The Fort Worth Better...

  14. Detailed search Miscellaneous

    E-Print Network [OSTI]

    Search Go Detailed search Miscellaneous Press sources (PhysicsWeb.org) Based on information from press sources (PhysicsWeb.org) Scientific Research; Nuclear Fusion; Renewable Sources of Energy

  15. Efficiency of Surveying, Baiting, and Trapping Wild Pigs at Fort Benning, Georgia Brian Lee Williams

    E-Print Network [OSTI]

    Ditchkoff, Steve

    Efficiency of Surveying, Baiting, and Trapping Wild Pigs at Fort Benning, Georgia by Brian Lee surveys, trapping efficiency, Fort Benning Copyright 2010 by Brian Lee Williams Approved by Stephen S This study, conducted at Fort Benning, Georgia, sought to develop more efficient ways of surveying

  16. School of Social Work Fort Collins, Colorado 80523-1586

    E-Print Network [OSTI]

    Rutledge, Steven

    School of Social Work Fort Collins, Colorado 80523-1586 Phone (970) 491-6612 Fax (970) 491-7280 Colorado State University College of Health and Human Sciences School of Social Work http or disability. #12;ii Greetings! Welcome to the School of Social Work at Colorado State University! Central

  17. Water Management Plan for Fort Buchanan, Puerto Rico

    SciTech Connect (OSTI)

    Chvala, William D.; Sullivan, Gregory P.; Mcmordie, Katherine

    2004-06-01T23:59:59.000Z

    This document reports findings and recommendations as a result of a design assistance project with Fort Buchanan with the goals of developing a Water Management Plan (WMP). The WRMP developed during this task is an amalgam of the templates and guidelines from the Federal Energy Management Program and Army regulations.

  18. Parton distributions and event generators Stefano Carrazza, Stefano Forte

    E-Print Network [OSTI]

    Heller, Barbara

    Parton distributions and event generators Stefano Carrazza, Stefano Forte Dipartimento di Fisica ingredient in achieving all of these goals is the integration of parton distri- butions within Monte Carlo, and data collected in an experimental fiducial region. Whereas next-to-leading (NLO) order Monte Carlo

  19. EIS-0090: Fort Peck-Havre Transmission Line Project, Montana

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy’s Western Area Power Administration prepared this statement to assess the potential environmental and socioeconomic implications of its proposed action to construct and operate a 230kV transmission line from Fort Peck to Havre, Montana, with three intermediate interconnecting substations.

  20. Regional analysis of rhythmic bedding in the Fort Hays limestone member, Niobrara Formation (Upper Cretaceous), US western interior

    SciTech Connect (OSTI)

    Laferriere, A.P.

    1987-01-01T23:59:59.000Z

    Results of a regional stratigraphic investigation of the rhythmically bedded Fort Hays limestone member of Kansas, Colorado, and New Mexico indicate at least two levels of cyclicity. Regional development of these cycles strongly supports the hypothesis that they are climatic in origin. Departures from simple cyclical patterns resulted from sedimentary effects of Late Cretaceous orogenic activity, erosional events associated with eustatic sea level changes, diagenetic modification, and possibly from interference between orbital parameters having different periodicities. The vulnerability of Milankovitch-type cyclicity to overprinting by tectono-sedimentologic effects makes units such as the Fort Hays useful as indicators of subtle tectonic activity. Regional thickness changes in groups of shale-limestone couplets were identified, correlated, and mapped in the subsurface using geophysical well log information in order to locate subtle structural elements that influenced Fort Hays sedimentation. In the Denver-Julesburg Basin of Colorado and western Kansas, thinning of the section between Fort Hays marker horizons occurs dominantly along northeastwardly trending belts that resulted apparently from Late Cretaceous reactivation of the Transcontinental Arch. Isotopic and petrographic analyses were conducted on pelagic (carbonate matrix) and benthic (inoceramid bivalve) constituents of selected shale/limestone couplets. These data suggest that there was little difference in temperature or salinity between times of terrigenous detrital input and times of nearly pure carbonate deposition. Isotopic information from matrix samples suggests a westward decrease in salinity of surface water in the Western Interior Sea. Isotopic data from largely unaltered inoceramid bivalves indicate bottom-water conditions of near-normal marine salinity.

  1. FRAMEWORK GEOLOGY OF FORT UNION COAL IN THE WILLISTON BASIN

    E-Print Network [OSTI]

    Chapter WF FRAMEWORK GEOLOGY OF FORT UNION COAL IN THE WILLISTON BASIN By R.M. Flores,1 C.W. Keighin,1 A.M. Ochs,2 P.D. Warwick,1 L.R. Bader,1 and E.C. Murphy3 in U.S. Geological Survey Professional Paper 1625-A 1 U.S. Geological Survey 2 Consultant, U.S. Geological Survey, Denver, Colorado 3 North

  2. Geothermal heat pumps at Fort Polk: Early results

    SciTech Connect (OSTI)

    Hughes, P.J.; Shonder, J.A.

    1996-12-31T23:59:59.000Z

    At Fort Polk, LA an entire city (4,003 military family housing units) is being converted to geothermal heat pumps (GHP) under a performance contract. At the same time other efficiency measures such as compact fluorescent lights (CFLs), low-flow water outlets, and attic insulation are being installed. If these contracts and this technology are to be used widely in US Department of Defense (DoD) facilities and other public buildings, better data from actual projects is the key. Being the first GHP project of this type and size, Fort Polk proved to be very challenging for all concerned. To get from RFP to start of construction took several years. This hard work by others created a once-in-a-lifetime opportunity to address many of the due diligence issues that delayed the Fort Polk project. So that future projects can move faster, an evaluation has been undertaken to address the following barriers: absence of a documented large-scale demonstration of GHP energy, demand, and maintenance savings (a barrier to acceptance by federal customers, performance contractors, and investors); newness of large-scale facility capital renewal procurements at federal facilities under energy savings performance contracts (ESPCs) or traditional appropriations (lack of case studies); and variability in current GHP design tools (increases risks and costs for federal customers, performance contractors, investors and designers). This paper presents early energy and demand savings results based on data collection through January 1996.

  3. Property Loss / Damage Report Damage Loss Details

    E-Print Network [OSTI]

    Ponce, V. Miguel

    Property Loss / Damage Report Damage Loss Details Date & Time of Damage / Loss: Type of damage / loss: Location - specific address / room: Project / Grant associated with damage / loss - grant Police: When was damage / loss first discovered - BY WHOM: Pictures available or attached? Was personal

  4. ARM - Detailed Experiment Description

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006Datastreamstwrcam40m Documentation DataDatastreamsxsaprhsrhi Documentation DataAlaskaDefensiveDetailed

  5. UoS Motor Accident Report Form COMPANY DETAILS

    E-Print Network [OSTI]

    Sussex, University of

    UNIV01FL02 UoS Motor Accident Report Form COMPANY DETAILS INSURED: University of Sussex ADDRESS: LOCATION: DESCRIPTION OF HOW ACCIDENT HAPPENED: PLEASE DRAW A SKETCH OF THE ACCIDENT: #12;DRIVER DETAILS: PREVIOUS ACCIDENTS: ADDRESS: VEHICLE DETAILS DATE VEHICLE PURCHASED: MAKE/MODEL: REGISTRATION: MILEAGE

  6. The evaluation of a 4000-home geothermal heat pump retrofit at Fort Polk, Louisiana: Final Report

    SciTech Connect (OSTI)

    Hughes, P.J.; Shonder, J.A.

    1998-03-01T23:59:59.000Z

    This report documents an independent evaluation of an energy retrofit of 4,003 family housing units at Fort Polk, Louisiana, under an energy savings performance contract (ESPC). Replacement of the heating, cooling, and water heating systems in these housing units with geothermal heat pumps (GHPs) anchored the retrofit; low-flow shower heads and compact fluorescent lighting were also installed, as well as attic insulation where needed. Statistically valid findings indicate that the project will save 25.8 million kWh, or 32.5% of the pre-retrofit whole-community electrical consumption, and 100% of the whole-community natural gas previously used for space conditioning and water heating (260,000 therms) in a typical meteorological year. At the end-use level, the GHPs were found to save about 42% of the pre-retrofit electrical consumption for heating, cooling, and water heating in housing units that were all-electric in the pre-retrofit period. This report also demonstrates an improved method of predicting energy savings. Using an engineering model calibrated to pre-retrofit energy use data collected in the field, the method predicted actual energy savings on one of the electric feeders at Fort Polk with a very high degree of accuracy. The accuracy of this model was in turn dependent on data-calibrated models of the geothermal heat pump and ground heat exchanger that are described in this report. In addition this report documents the status of vertical borehole ground heat exchanger (BHEx) design methods at the time this project was designed, and demonstrates methods of using data collected from operating GHP systems to benchmark BHEx design methods against a detailed engineering model calibrated to date. The authors also discuss the ESPC`s structure and implementation and how the experience gained here can contribute to the success of future ESPCs.

  7. U.S. Army Fort Knox: Using the Earth for Space Heating and Cooling (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2010-04-01T23:59:59.000Z

    FEMP case study overview of the geothermal/ground source heat pump project at the U.S. Army Fort Knox Disney Barracks.

  8. An evaluation of the Fort Polk energy savings performance contract

    SciTech Connect (OSTI)

    Hughes, P.J.; Shonder, J.A.

    1998-11-01T23:59:59.000Z

    The US Army, in cooperation with an energy services company (ESCO), used private capital to retrofit 4,003 family housing units on the Fort Polk, Louisiana, military base with geothermal heat pumps (GHPs). The project was performed under an energy savings performance contract (ESPC) that provides for the Army and the ESCO to share the cost savings realized through the energy retrofit over the 20-year life of the contract. Under the terms of the contract, the ESCO is responsible for maintaining the GHPs and provides ongoing measurement and verification (M and V) to assure cost and energy savings to the Army. An independent evaluation conducted by the Department of Energy`s Oak Ridge National Laboratory indicates that the GHP systems in combination with other energy retrofit measures have reduced annual whole-community electrical consumption by 33%, and natural gas consumption by 100%. These energy savings correspond to an estimated reduction in CO{sub 2} emissions of 22,400 tons per year. Peak electrical demand has been reduced by 43%. The electrical energy and demand savings correspond to an improvement in the whole-community annual electric load factor from 0.52 to 0.62. As a result of the project, Fort Polk saves about $450,000 annually and benefits from complete renewal of the major energy consuming systems in family housing and maintenance of those systems for 20 years. Given the magnitude of the project, the cost and energy savings achieved, and the lessons learned during its design and implementation, the Fort Polk ESPC can provide a model for other housing-related energy savings performance contracts in both the public and private sectors.

  9. An Evaluation of the Fort Polk Energy Savings Performance Contract

    SciTech Connect (OSTI)

    Hughes, Patrick [ORNL; Shonder, John A [ORNL

    1998-08-01T23:59:59.000Z

    The US Army, in cooperation with an energy services company (ESCO), used private capital to retrofit 4003 family housing units on the Fort Polk, Louisiana, military base with geothermal heat pumps (GHPs). The project was performed under an energy savings performance contract (ESPC) that provides for the army and the ESCO to share the cost savings realized through the energy retrofit over the 20-year life of the contract. Under the terms of the contract, the ESCO is responsible for maintaining the GHPs and provides ongoing measurement and verification (M&V) to assure cost and energy savings to the Army. An independent evaluation conducted by the Department of Energy's Oak Ridge National Laboratory indicates that the GHPS systems in combination with other energy retrofit measures have reduced annual whole-community electrical consumption by 33%, and natural gas consumption by 100%. These energy savings correspond to an estimated reduction in CO{sub 2} emissions of 22,400 tons per year. Peak electrical demand has been reduced by 43%. The electrical energy and demand savings correspond to an improvement in the whole-community annual electric load factor from 0.52 to 0.62. As a result of the project, Fort Polk saves about $450,000 annually and benefits from complete renewal of the major energy consuming systems in family housing and maintenance of those systems for 20 years. Given the magnitude of the project, the cost and energy savings achieved, and the lessons learned during its design and implementation, the Fort Polk ESPC can provide a model for other housing-related energy savings performance contracts in both the public and private sectors.

  10. Development of a composite satellite structure for FORTE

    SciTech Connect (OSTI)

    Grastataro, C.I.; Butler, T.A.; Smith, B.G.; Thompson, T.C.

    1995-04-01T23:59:59.000Z

    The Los Alamos National Laboratory (LANL) in partnership with Composite Optics Incorporated (COI) has advanced the development of low-cost, lightweight, composite technology for use in small satellite structures, in this case, for the Fast On-Orbit Recording of Transient Events (FORTE) satellite mission. The use of advanced composites in space applications is well developed, but the application of an all-composite satellite structure has not been achieved until now. This paper investigates the application of composite technology in the design of an all-composite spacecraft structure for small satellites. Engineering analysis and test results obtained from the development of the spacecraft engineering model are also presented.

  11. Fort Bend County, Texas: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489Information HydroFontana,dataset nameFort Bend County, Texas:

  12. Fort Defiance, Arizona: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489Information HydroFontana,dataset nameFort Bend County,

  13. Fort Lauderdale, Florida: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489Information HydroFontana,dataset nameFort Bend

  14. Fort Lupton, Colorado: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489Information HydroFontana,dataset nameFort BendLupton,

  15. Fort Wayne, Indiana: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489Information HydroFontana,dataset nameFort

  16. Fort Belknap Electric Coop Inc | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnual SiteofEvaluating A PotentialJumpGermanFife Energy ParkForked Deer ElectricFort Belknap

  17. Radiometrics At Fort Bliss Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to:Ezfeedflag JumpID-f < RAPID‎ | Roadmap Jump to:b <RGS Development BVRadiantRadioFort

  18. Boralex Fort Fairfield Biomass Facility | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty EditCalifornia: EnergyAvignon,BelcherBlundell 1Fort Fairfield Biomass Facility Jump

  19. DOE - Office of Legacy Management -- Fort St Vrain - 011

    Office of Legacy Management (LM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOn AprilA group currentBradleyTable ofArizonaBuffalo -Elk River ReactorProjectFordhamFort

  20. Town of Fort Laramie, Wyoming (Utility Company) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty Edit withTianlin Baxin Hydropower Station JumpOpenEITown ofTown of Fort Laramie,

  1. Town of Fort Supply, Oklahoma (Utility Company) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualProperty Edit withTianlin Baxin Hydropower Station JumpOpenEITown ofTown of Fort Laramie,Town

  2. Fort Bliss, Texas: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are8COaBulkTransmissionSitingProcess.pdf Jump to:ar-80m.pdfFillmoreGabbs ValleyCity,ForkedAdd aNorthFort BlissBliss,

  3. Fort Boise Veteran's Hospital District Heating Low Temperature Geothermal

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are8COaBulkTransmissionSitingProcess.pdf Jump to:ar-80m.pdfFillmoreGabbs ValleyCity,ForkedAdd aNorthFort

  4. Fort Carson, Colorado: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are8COaBulkTransmissionSitingProcess.pdf Jump to:ar-80m.pdfFillmoreGabbs ValleyCity,ForkedAdd aNorthFortCarson,

  5. New York-Presbyterian Outpatient Laboratory Locations At the following facilities, the $150 copay for Lab and Radiology services is

    E-Print Network [OSTI]

    Grishok, Alla

    New York-Presbyterian Outpatient Laboratory Locations At the following facilities, the $150 copay for Lab and Radiology services is waived for participants in the UHC and Cigna POS 100 Plans. LOCATION facility) 161 Fort Washington New York, NY 10032 Monday-Friday, 8 a.m. - 6 p.m. Saturday, 8 a.m. - 12 noon

  6. Air Quality and Road Emission Results for Fort Stewart, Georgia

    SciTech Connect (OSTI)

    Kirkham, Randy R.; Driver, Crystal J.; Chamness, Mickie A.; Barfuss, Brad C.

    2004-02-02T23:59:59.000Z

    The Directorate of Public Works Environmental & Natural Resources Division (Fort Stewart /Hunter Army Airfield) contracted with the Pacific Northwest National Laboratory (PNNL) to monitor particulate matter (PM) concentrations on Fort Stewart, Georgia. The purpose of this investigation was to establish a PM sampling network using monitoring equipment typically used in U.S. Environmental Protection Agency (EPA) ''saturation sampling'', to determine air quality on the installation. In this initial study, the emphasis was on training-generated PM, not receptor PM loading. The majority of PM samples were 24-hr filter-based samples with sampling frequency ranging from every other day, to once every six days synchronized with the EPA 6th day national sampling schedule. Eight measurement sites were established and used to determine spatial variability in PM concentrations and evaluate whether fluctuations in PM appear to result from training activities and forest management practices on the installation. Data collected to date indicate the average installation PM2.5 concentration is lower than that of nearby urban Savannah, Georgia. At three sites near the installation perimeter, analyses to segregate PM concentrations by direction of air flow across the installation boundary indicate that air (below 80 ft) leaving the installation contains less PM2.5 than that entering the installation. This is reinforced by the observation that air near the ground is cleaner on average than the air at the top of the canopy.

  7. Innovative use of DSP technology in space: FORTE event classifier

    SciTech Connect (OSTI)

    Briles, S.; Moore, K. Jones, R.; Klingner, P.; Neagley, D.; Caffrey, M.; Henneke, K.; Spurgen, W. [Los Alamos National Lab., NM (United States); Blain, P. [EG and G Idaho, Inc., Idaho Falls, ID (United States)

    1994-08-01T23:59:59.000Z

    The Fast On-Orbit Recording of Transient Events (FORTE) small satellite will field a digital signal processor (DSP) experiment for the purpose of classifying radio-frequency (rf) transient signals propagating through the earth`s ionosphere. Designated the Event Classifier experiment, this DSP experiment uses a single Texas Instruments` SMJ320C30 DSP to execute preprocessing, feature extraction, and classification algorithms on down-converted, digitized, and buffered rf transient signals in the frequency range of 30 to 300 MHz. A radiation-hardened microcontroller monitors DSP- abnormalities and supervises spacecraft command communications. On- orbit evaluation of multiple algorithms is supported by the Event Classifier architecture. Ground-based commands determine the subset and sequence of algorithms executed to classify a captured time series. Conventional neural network classification algorithms will be some of the classification techniques implemented on-board FORTE while in a low-earth orbit. Results of all experiments, after being stored in DSP flash memory, will be transmitted through the spacecraft to ground stations. The Event Classifier is a versatile and fault-tolerant experiment that is an important new space-based application of DSP technology.

  8. Dust Plume Modeling at Fort Bliss: Full Training Scenario

    SciTech Connect (OSTI)

    Chapman, Elaine G.; Rishel, Jeremy P.; Rutz, Frederick C.; Seiple, Timothy E.; Newsom, Rob K.; Allwine, K Jerry

    2006-09-26T23:59:59.000Z

    The potential for air quality impacts from heavy mechanized vehicles operating in the training ranges and on the unpaved main supply routes at Fort Bliss is being investigated. The investigation uses the atmospheric modeling system DUSTRAN to simulate fugitive dust emission and dispersion from typical activities occurring on the installation. This report conveys the results of DUSTRAN simulations conducted using a “Full Training” scenario developed by Fort Bliss personnel. he Full Training scenario includes simultaneous off-road activities of two full Heavy Brigade Combat Teams (HCBTs) and one HCBT battalion on three training ranges. Simulations were conducted for the six-day period, April 25-30, 2005, using previously archived meteorological records. Simulation results are presented in the form of 24-hour average PM10 plots and peak 1-hour PM10 concentration plots, where the concentrations represent contributions resulting from the specified military vehicular activities, not total ambient PM10 concentrations. Results indicate that the highest PM10 contribution concentrations occurred on April 30 when winds were light and variable. Under such conditions, lofted particulates generated by vehicular movement stay in the area of generation and are not readily dispersed. The effect of training duration was investigated by comparing simulations with vehicular activity extending over a ten hour period (0700 to 1700 MST) with simulations where vehicular activity was compressed into a one hour period (0700 to 0800 MST). Compressing all vehicular activity into one hour led to higher peak one-hour and 24-hour average concentration contributions, often substantially higher.

  9. CMPE 185 Spring 1998 Syllabus 1 1 Administrative details

    E-Print Network [OSTI]

    Karplus, Kevin

    CMPE 185 Spring 1998 Syllabus 1 Syllabus 1 Administrative details Location and time Kresge 327, MWF of the quarter, and 10% on in­class work, Karplus & Larrabee Info 1 #12; 2 Syllabus CMPE 185 Spring 1998

  10. CMPE 185 Fall 1999 Syllabus 1 1 Administrative details

    E-Print Network [OSTI]

    Karplus, Kevin

    CMPE 185 Fall 1999 Syllabus 1 Syllabus 1 Administrative details Location and time Kresge 327, MWF 2 Syllabus CMPE 185 Fall 1999 4 Special guest lecturers I may arrange to have some guest lectures

  11. CMPE 185 Winter 1999 Syllabus 1 1 Administrative details

    E-Print Network [OSTI]

    Karplus, Kevin

    CMPE 185 Winter 1999 Syllabus 1 Syllabus 1 Administrative details Location and time Porter 144, MWF). Everything must be turned in by the last day of class, Friday March 12. Karplus Info 1 #12; 2 Syllabus CMPE

  12. CMPE 185 Fall 2000 Syllabus 1 1 Administrative details

    E-Print Network [OSTI]

    Karplus, Kevin

    CMPE 185 Fall 2000 Syllabus 1 Syllabus 1 Administrative details Location and time Kresge 327, MWF 2, and need to do the grading mostly on Dec 2. Karplus Info 1 #12; 2 Syllabus CMPE 185 Fall 2000 4 Special

  13. Analysis of natural gas supply strategies at Fort Drum

    SciTech Connect (OSTI)

    Stucky, D.J.; Shankle, S.A.; Anderson, D.M.

    1992-07-01T23:59:59.000Z

    This analysis investigates strategies for Fort Drum to acquire a reliable natural gas supply while reducing its gas supply costs. The purpose of this study is to recommend an optimal supply mix based on the life-cycle costs of each strategy analyzed. In particular, this study is intended to provide initial guidance as to whether or not the building and operating of a propane-air mixing station is a feasible alternative to the current gas acquisition strategy. The analysis proceeded by defining the components of supply (gas purchase, gas transport, supplemental fuel supply); identifying alternative options for each supply component; constructing gas supply strategies from different combinations of the options available for each supply component and calculating the life-cycle costs of each supply strategy under a set of different scenarios reflecting the uncertainty of future events.

  14. Landscape influences on headwater streams on Fort Stewart, Georgia, USA

    SciTech Connect (OSTI)

    Jager, Yetta [ORNL; Bevelhimer, Mark S [ORNL; al., et. [Various Institutes

    2011-01-01T23:59:59.000Z

    Military landscapes represent a mixture of undisturbed natural ecosystems, developed areas, and lands that support different types and intensities of military training. Research to understand water-quality influences of military landscapes usually involves intensive sampling in a few watersheds. In this study, we developed a survey design of accessible headwater watersheds intended to improve our ability to distinguish land water relationships in general, and training influences, in particular, on Fort Stewart, GA. We sampled and analyzed water from watershed outlets. We successfully developed correlative models for total suspended solids (TSS), total nitrogen (TN), organic carbon (OC), and organic nitrogen (ON), which dominated in this blackwater ecosystem. TSS tended to be greater in samples after rainfall and during the growing season, and models that included %Wetland suggested a build-and-flush relationship. We also detected a positive association between TSS and tank-training, which suggests a need to intercept sediment-laden runoff from training areas. Models for OC showed a negative association with %Grassland. TN and ON both showed negative associations with %Grassland, %Wetland, and %Forest. Unexpected positive associations were observed between OC and equipmenttraining activity and between ON and %Bare ground ? Roads. Future studies that combine our survey-based approach with more intensive monitoring of the timing and intensity of training would be needed to better understand the mechanisms for these empirical relationships involving military training. Looking beyond local effects on Fort Stewart streams, we explore questions about how exports of OC and nitrogen from coastal military installations ultimately influence estuaries downstream.

  15. Characterization plan for Fort St. Vrain and Peach Bottom graphite fuels

    SciTech Connect (OSTI)

    Maarschman, S.C.; Berting, F.M.; Clemmer, R.G.; Gilbert, E.R.; Guenther, R.J.; Morgan, W.C.; Sliva, P.

    1993-09-01T23:59:59.000Z

    Part of Fort St. Vrain (FSV) and most of the Peach Bottom (PB) reactor spent fuels are currently stored at INEL and may remain in storage for many years before disposal. Three disposal pathways have been proposed: intact disposal, fuels partially disassembled and the high-level waste fraction conditioned prior to disposal, and fuels completed disassembled and conditioned prior to disposal. Many options exist within each of these pathways. PNL evaluated the literature and other reference to develop a fuels characterization plan for these fuels. This plan provides guidance for the characteristics of the fuel which will be needed to pursue any of the storage or disposal pathways. It also provides a suggested fuels monitoring program for the current storage facilities. This report recommends a minimum of 7 fuel elements be characterized: PB Core 1 fuel: one Type II nonfailed element, one Type II failed element, and one Type III nonfailed element; PB Core 2 fuel: two Type II nonfailed fuel elements; and FSV fuel: at least two fuel blocks from regions of high temperature and fluence and long in-reactor performance (preferably at reactor end-of- life). Selection of PB fuel elements should focus on these between radial core position 8 and 14 and on compacts between compact numbers 10 and 20. Selection of FSV fuel elements should focus on these from Fuel Zones II and III, located in Core Layers 6, 7, and possibly 8.

  16. Fort Smith, mother post of the southwest quartermaster supply and archeological patterning

    E-Print Network [OSTI]

    Bento, Sylvia Deborah

    1988-01-01T23:59:59.000Z

    is the site of the second Fort Smith on a relatively level terrace reaching an elevation of 440 to 455 feet AMSL. This terrace extends east beyond the park boundary about three quarters of a mile until uplands are encountered. The majority of the park... of Fort Smith became a topic of concern to the War Department . On July 8, 1845, General Thomas Jesup 'I f irst Quartermaster General of the United States Army, was sent to examine "the site of Fort Smith in its relation to the line of defense...

  17. Limited Energy Engineering Analysis (EEAP) study of summer boiler at high temperature hot water plants, Fort Leonard Wood, Missouri. Final report

    SciTech Connect (OSTI)

    NONE

    1993-09-02T23:59:59.000Z

    This report is a study of the existing High Temperature Hot Water Distribution Systems at Fort Leonard Wood, Missouri. There are two systems with central boilers located in Buildings 1021 and 2369. The study focuses on the operation of the boilers during the summer months which is required to provide domestic hot water and sanitizing steam to various buildings. Because the boilers are operating under a reduced load condition, it may be cost effective in terms of energy conservation to implement one of the following energy conservation opportunities (ECO`s).

  18. A SUMMARY OF COAL IN THE FORT UNION FORMATION (TERTIARY), BIGHORN BASIN,

    E-Print Network [OSTI]

    Chapter SB A SUMMARY OF COAL IN THE FORT UNION FORMATION (TERTIARY), BIGHORN BASIN, WYOMING assessment of selected Tertiary coal beds and zones in the Northern RockyMountains and Great Plains region, U...........................................................................................................................SB-1 Coal Production History

  19. An ozone climatology of the Dallas-Fort Worth area and its relationship to meteorology 

    E-Print Network [OSTI]

    Nobis, Timothy Edward

    1998-01-01T23:59:59.000Z

    The Environmental protection agency has established a hics. National Ambient Air Quality Standard for surface ozone through the Clean Air Act and its amendments. The Dallas / Fort Worth area is in violation of these standards, and to date...

  20. City of Fort Collins- Green Building Requirement for City-Owned Buildings

    Broader source: Energy.gov [DOE]

    The City Council of Fort Collins passed a resolution in September 2006, establishing green building goals for new city-owned buildings of 5,000 square feet or more. New buildings must be designed...

  1. Contour Ripping and Composted Dairy Manure for Erosion Control on Fort Hood Military Installation, Texas 

    E-Print Network [OSTI]

    Prcin, Lisa J.

    2010-07-14T23:59:59.000Z

    erosion. This investigation examined two conservation practices directed at improving and creating sustainable training conditions on Fort Hood training lands, contour ripping and the application of composted dairy manure. The application of composted...

  2. Fort Collins Utilities- Residential On-Bill Financing Program Program (Colorado)

    Broader source: Energy.gov [DOE]

    Fort Collins offers its residential customers low-interest loans that may be used to finance a variety of projects including adding insulation, replacing a furnace, upgrading water and space...

  3. Contour Ripping and Composted Dairy Manure for Erosion Control on Fort Hood Military Installation, Texas

    E-Print Network [OSTI]

    Prcin, Lisa J.

    2010-07-14T23:59:59.000Z

    erosion. This investigation examined two conservation practices directed at improving and creating sustainable training conditions on Fort Hood training lands, contour ripping and the application of composted dairy manure. The application of composted...

  4. Reassembling the rolling bridge : an art gallery at Fort Point Channel, Boston

    E-Print Network [OSTI]

    Lim, Winston E

    1996-01-01T23:59:59.000Z

    Spanning the Fort Point Channel for nearly a century, Boston's Rolling Bridge is a familiar landmark to many railway commuters and residents of the city. Its robust steel assembly, characterized by three anthropomorphic ...

  5. Urban tree maintenance scheduling: a case study using Fort Worth's METRIS geo data base

    E-Print Network [OSTI]

    Mirenda, Joseph Salvatore

    1981-01-01T23:59:59.000Z

    URBAN TREE MAINTENANCE SCHEDULING: A CASE STUDY USING FORT WORTH'S METRIS GEO DATA BASE A Thesis JOSEPH SALVATORE MIRENDA Submitted to the Graduate College of Texas A&M University in partial fulfillment of the requirement for the degree... of MASTER OF SCIENCE December, 1981 Major Subject: Forestry URBAN TREE MAINTENANCE SCHEDULING: A CASE STUDY USING FORT WORTH'S METRIS GEO DATA BASE A Thesis by JOSEPH SALVATORE MIRENDA Approved as to style and content by: Dr. Robert D. Baker...

  6. Facility Energy Decision System (FEDS) Assessment Report for Fort Buchanan, Puerto Rico

    SciTech Connect (OSTI)

    Chvala, William D.; Solana, Amy E.; Dixon, Douglas R.

    2005-02-01T23:59:59.000Z

    This report documents the findings of the Facility Energy Decision System (FEDS) assessment at Fort Buchanan, Puerto Rico, by a team of PNNL engineers under contract to the Installation Management Agency (IMA) Southeast Region Office (SERO). Funding support was also provided by the Department of Energy's Federal Energy Management Program. The purpose of the assessment was to determine how energy is consumed at Fort Buchanan, identify the most cost-effective energy retrofit measures, and calculate the potential energy and cost savings.

  7. Identification and prehistoric exploitation of chert from Fort Hood, Bell and Coryell counties, Texas

    E-Print Network [OSTI]

    Dickens, William Alan

    1995-01-01T23:59:59.000Z

    IDENTIFICATION AND PREHISTORIC EXPLOITATION OF CHERT FROM FORT HOOD, BELL AND CORYELL COUNTIES, TEXAS A Thesis by WILLIAM ALAN DICKENS Submitted to the Office of Graduate Studies of Texas ASM University in partial fulfillment... of the requirements for the degree of MASTER OF ARTS May 1995 Major Subject: Anthropology IDENTIFICATION AND PREHISTORIC EXPLOITATION OF CHERT FROM FORT HOOD, BELL AND CORYELL COUNTIES, TEXAS A Thesis by WILLIAM ALAN DICKENS Submitted to Texas A&M University...

  8. Trace fossils of Fort Hays Limestone Member of Niobrara Chalk (Upper Cretaceous), west-central Kansas

    E-Print Network [OSTI]

    Frey, R. W.

    1970-07-17T23:59:59.000Z

    THE UNIVERSITY OF KANSAS PALEONTOLOGICAL CONTRIBUTIONS ARTICLE 53 (CRETACEOUS 2) TRACE FOSSILS OF FORT HAYS LIMESTONE MEMBER OF NIOBRARA CHALK (UPPER CRETACEOUS), WEST-CENTRAL KANSAS ROBERT W. FREY University of Georgia Marine Institute, Sapelo... Figures, 10 Plates, 4 Tables TRACE FOSSILS OF FORT HAYS LIMESTONE MEMBER OF NIOBRARA CHALK (UPPER CRETACEOUS), WEST-CENTRAL KANSAS' ROBERT W. FREY University of Georgia Marine Institute, Sapelo Island, Georgia CONTENTS PAGE PAGE ABSTRACT 5 Thalassinoides...

  9. Market segmentation of visitors to Fort Wilkins State Park using a hierarchical clustering approach

    E-Print Network [OSTI]

    Fisher, Thomas Mark

    1980-01-01T23:59:59.000Z

    MARKET SEGMENTATION OF VISITORS TO FORT WILKINS STATE PARK USING A HIERARCHICAL CLUSTERING APPROACH A Thesis by THOMAS MARK FISHER Submitted to the Graduate College of Texas AAM University in partial fulfillment of the requirement... for the degree of MASTER OF SCIENCE August 1980 Major Subject: Recreation and Resources Development MARKET SEGMENTATION OF VISITORS TO FORT WILKINS STATE PARK USING A HIERARCHICAL CLUSTERING APPROACH A Thesis by THOMAS MARK FISHER Approved as to style...

  10. Habitat Restoration/Enhancement Fort Hall Reservation : 2008 Annual Report.

    SciTech Connect (OSTI)

    Osborne, Hunter [Shoshone Bannock Tribes

    2009-07-23T23:59:59.000Z

    Habitat enhancement, protection and monitoring were the focus of the Resident Fisheries Program during 2008. Enhancement and protection included sloping, fencing and planting wetlands plugs at sites on Spring Creek (Head-waters). Many previously constructed instream structures (rock barbs and wing dams) were repaired throughout the Fort Hall Indian Reservation (Reservation). Physical sampling during 2008 included sediment and depth measurements (SADMS) in Spring Creek at the Car Removal site. SADMS, used to track changes in channel morphology and specifically track movements of silt through Bottoms stream systems were completed for 5 strata on Spring Creek. Water temperature and chemistry were monitored monthly on Spring Creek, Clear Creek, Diggie Creek, and Portneuf (Jimmy Drinks) and Blackfoot rivers. Fish population densities and biomass were sampled in five reservation streams which included nine sites. Sampling protocols were identical to methods used in past years. Numbers of fish in Spring Creek series remained relatively low, however, there was an increase of biomass overall since 1993. Salmonid fry densities were monitored near Broncho Bridge and were similar to 2006, and 2007, however, as in years past, high densities of macrophytes make it very difficult to see fry in addition to lack of field technicians. Mean catch rate by anglers on Bottoms streams stayed the same as 2007 at 1.5/hr. Numbers of fish larger than 18-inches caught by anglers increased from 2007 at .20 to .26/hr.

  11. Water Reclamation and Reuse at Fort Carson: Best Management Practice Case Study #14 - Alternate Water Sources (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2009-08-01T23:59:59.000Z

    FEMP Water Efficiency Best Management Practice #14 Case Study: Overview of the water reclamation and reuse program at the U.S. Army's Fort Carson.

  12. Improving alternative fuel utilization: detailed kinetic combustion...

    Energy Savers [EERE]

    Improving alternative fuel utilization: detailed kinetic combustion modeling & experimental testing Improving alternative fuel utilization: detailed kinetic combustion modeling &...

  13. Fort Smith, mother post of the southwest quartermaster supply and archeological patterning 

    E-Print Network [OSTI]

    Bento, Sylvia Deborah

    1988-01-01T23:59:59.000Z

    the supplies and haul them to Fort Smith. This process was extremely time consuming and expensive. When steamers attempted to ride the low water they would often collide with floating debris and become stranded. The steamer New World was stuck 10 miles... below Pine Bluff ? Arkansas? for six months (NcClel land 18'55) . Unable to get the vessel out of the r iver & the For t Smith quartermaster, then Captain French& knew that a way had to be found to get the stores from the steamer to Fort Smith...

  14. Rhythmic bedding patterns for locating structural features, Niobrara Formation, United States western interior

    SciTech Connect (OSTI)

    Laferriere, A.P.; Hattin, D.E.

    1989-05-01T23:59:59.000Z

    Milankovitch-type bedding cycles are well developed in the Upper Cretaceous Fort Hays Limestone Member, Niobrara Formation. These time-equivalent cycles can be correlated across much of Colorado, Kansas, and northeastern New Mexico by combining subsurface and outcrop data. Documentation of thickness variations within the regionally persistent Fort Hays bedding sequences furnishes a basis for fine-scale analysis of Late Cretaceous crustal movements within the eastern ramp region of the Western Interior foreland basin. Regional thickness changes in groups of shale-limestone couplets were correlated and mapped in outcrop and in the subsurface to locate structural elements that influenced Fort Hays deposition. In the Denver-Julesburg basin of Colorado and western Kansas, up to 6.1 m (20 ft) of thinning of the section occurs dominantly along northeastwardly trending belts formed during Late Cretaceous reactivation of the Transcontinental arch. Mapping of these small-scale thickness changes in the Fort Hays demonstrates that Cretaceous reactivation of the Transcontinental arch was not restricted to the northern part of the Denver-Julesburg basin. Additional structures may occur as far south as the Colorado-New Mexico border. A northwestwardly thinning trend is also apparent and may have resulted from increased compaction and diagenesis, reduction of sediment input during transgression, or from uplift in the vicinity of the Colorado Front Range. 8 figures.

  15. 2003 CBECS Detailed Tables: Summary

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40Coal Stocks at Commercial andSeptember 25,9,1996 N Y M E2003 Detailed Tables 2003

  16. Electric Power detailed State data

    U.S. Energy Information Administration (EIA) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere IRaghuraji Agro IndustriesTownDells, Wisconsin:DeploymentSite Name: Email: Terminal2,7,7,of GreenhouseDetailed

  17. 1490 Campus Delivery Fort Collins, Colorado 80523-1490

    E-Print Network [OSTI]

    Management Program (ITAM): -Don Applegate -Christopher Long -Blaize Uva Work Location: Camp Roberts and Camp nominations. The Integrated Training Area Management (ITAM) Program is responsible for maintaining the training lands of California Army National Guard (CAARNG) installations. The ITAM Program supports

  18. Library Locations Locations other than Main Library

    E-Print Network [OSTI]

    Library Locations Locations other than Main Library Example: Feminist Studies HQ1410 .U54 2009 University of California, Santa Barbara Library www.library.ucsb.edu Updated 3-2014 A - B.......................................6 Central M - N..................................................Arts Library (Music Building) P

  19. Geothermal Space Heating Applications for the Fort Peck Indian Reservation in the Vicinity of Poplar, Montana. Phase I Report, August 20, 1979--December 31, 1979

    SciTech Connect (OSTI)

    Spencer, Glenn J.; Cohen, M. Jane

    1980-01-04T23:59:59.000Z

    This engineering and economic study is concerned with the question of using the natural heat of the earth, or geothermal energy, as an alternative to other energy sources such as oil and natural gas which are increasing in cost. This document represents a quarterly progress report on the effort directed to determine the availability of geothermal energy within the Fort Peck Indian Reservation, Montana (Figure 1), and the feasibility of beneficial use of this resource including engineering, economic and environmental considerations. The project is being carried out by the Tribal Research office, Assinboine and Sioux Tribes, Fort Peck Indian Reservation, Poplar, Montana under a contract to the United States Department of Energy. PRC TOUPS, the major subcontractor, is responsible for engineering and economic studies and the Council of Energy Resource Tribes (CERT) is providing support in the areas of environment and finance, the results of which will appear in the Final Report. The existence of potentially valuable geothermal resource within the Fort Peck Indian Reservation was first detected from an analysis of temperatures encountered in oil wells drilled in the area. This data, produced by the Montana Bureau of Mines and Geology, pointed to a possible moderate to high temperature source near the town of Poplar, Montana, which is the location of the Tribal Headquarters for the Fort Peck Reservation. During the first phase of this project, additional data was collected to better characterize the nature of this geothermal resource and to analyze means of gaining access to it. As a result of this investigation, it has been learned that not only is there a potential geothermal resource in the region but that the producing oil wells north of the town of Poplar bring to the surface nearly 20,000 barrels a day (589 gal/min) of geothermal fluid in a temperature range of 185-200 F. Following oil separation, these fluids are disposed of by pumping into a deep groundwater aquifer. While beneficial uses may be found for these geothermal fluids, even higher temperatures (in excess of 260 F) may be found directly beneath the town of Poplar and the new residential development which is being planned in the area. This project is primarily concerned with the use of geothermal energy for space heating and domestic hot water for the town of Poplar (Figure 2 and Photograph 1) and a new residential development of 250 homes which is planned for an area approximately 4 miles east of Poplar along U.S. Route 2 (Figure 2 and Photograph 2). A number of alternative engineering design approaches have been evaluated, and the cost of these systems has been compared to existing and expected heating costs.

  20. EIS-0069: Solvent Refined Coal-II Demonstration Project, Fort Martin, Monongalia County, West Virginia

    Broader source: Energy.gov [DOE]

    The U.S. Department of Energy developed this statement to assess the potential environmental, economic and social impacts associated with the construction and short-term operation of a 6,000-tons-per-stream-day-capacity facility that will demonstrate the technical operability, economic viability, and environmental acceptability of the solvent refined coal process at Fort Martin, West Virginia.

  1. FORT UNION COAL IN THE POWDER RIVER BASIN, WYOMING AND MONTANA: A SYNTHESIS

    E-Print Network [OSTI]

    Chapter PS FORT UNION COAL IN THE POWDER RIVER BASIN, WYOMING AND MONTANA: A SYNTHESIS By R of selected Tertiary coal beds and zones in the Northern RockyMountains and Great Plains region, U Resource assessment of selected Tertiary coal beds and zones in the Northern Rocky Mountains and Great

  2. FORT UNION COAL IN THE GREATER GREEN RIVER BASIN, EAST FLANK OF THE ROCK SPRINGS UPLIFT,

    E-Print Network [OSTI]

    Chapter GS FORT UNION COAL IN THE GREATER GREEN RIVER BASIN, EAST FLANK OF THE ROCK SPRINGS UPLIFT 1999 Resource assessment of selected Tertiary coal beds and zones in the Northern Rocky in the toolbar to return. 1999 Resource assessment of selected Tertiary coal beds and zones in the Northern Rocky

  3. BOCA RATON DANIA BEACH DAVIE FORT LAUDERDALE HARBOR BRANCH JUPITER PORT ST. LUCIE Educational Plant Survey

    E-Print Network [OSTI]

    Fernandez, Eduardo

    BOCA RATON DANIA BEACH DAVIE FORT LAUDERDALE HARBOR BRANCH JUPITER PORT ST. LUCIE Educational Plant Survey 2011/2012 ­ 2016/2017 Approved by FAU BOT on June 15, 2011 #12;EDUCATIONAL PLANT SURVEY Florida ...................................................................................................................... ii Educational Plant Survey Team

  4. Jordan Cove Energy Project Fort Chicago Energy Partners L.P.

    E-Print Network [OSTI]

    Jordan Cove Energy Project Fort Chicago Energy Partners L.P. 1.0 Bcfd Coos Bay, Oregon Oregon LNG Funding Partners 1.0-1.5 Bcfd Astoria, Oregon Portwestward LNG Facility Portwestward LNG, LLC 0.7-1.25 Bcfd Clatskanie, Oregon Kitimat LNG Facility Apache Corp 0.64 -1.0 Bcfd Kitimat, British Columbia

  5. FRAMEWORK GEOLOGY OF FORT UNION COAL IN THE EASTERN ROCK SPRINGS UPLIFT,

    E-Print Network [OSTI]

    Chapter GF FRAMEWORK GEOLOGY OF FORT UNION COAL IN THE EASTERN ROCK SPRINGS UPLIFT, GREATER GREEN RIVER BASIN, WYOMING By R.M. Flores,1 A.M. Ochs,2 and L.R. Bader1 in U.S. Geological Survey Professional Paper 1625-A 1 U.S. Geological Survey 2 Consultant, U.S. Geological Survey, Denver, Colorado 1999

  6. WARNER COLLEGE OF NATURAL RESOURCES 1401 Campus Delivery Fort Collins, CO 80523-1401

    E-Print Network [OSTI]

    and Protected Area· Management Natural Resources Management Rangeland Ecology Range and Forest ManagementWARNER COLLEGE OF NATURAL RESOURCES 1401 Campus Delivery · Fort Collins, CO 80523-1401 (970) 491 Science· Forest Management· Forestry Business· Geology Environmental Geology· Geology· Natural Resource

  7. Survival Estimates of White-tailed Deer Fawns at Fort Rucker, Alabama Angela Marie Jackson

    E-Print Network [OSTI]

    Ditchkoff, Steve

    Survival Estimates of White-tailed Deer Fawns at Fort Rucker, Alabama by Angela Marie Jackson for the Degree of Master of Science Auburn, Alabama August 6, 2011 Keywords: White-tailed deer, fawn survival, coyote, predator-prey theory Copyright 2011 by Angela Marie Jackson Approved by Stephen S. Ditchkoff

  8. Crump Geyser: High Precision Geophysics & Detailed Structural...

    Broader source: Energy.gov (indexed) [DOE]

    Crump Geyser: High Precision Geophysics & Detailed Structural Exploration & Slim Well Drilling Crump Geyser: High Precision Geophysics & Detailed Structural Exploration & Slim Well...

  9. Fort Lewis natural gas and fuel oil energy baseline and efficiency resource assessment

    SciTech Connect (OSTI)

    Brodrick, J.R. [USDOE, Washington, DC (United States); Daellenbach, K.K.; Parker, G.B.; Richman, E.E.; Secrest, T.J.; Shankle, S.A. [Pacific Northwest Lab., Richland, WA (United States)

    1993-02-01T23:59:59.000Z

    The mission of the US Department of Energy (DOE) Federal Energy Management Program (FEMP) is to lead the improvement of energy efficiency and fuel flexibility within the federal sector. Through the Pacific Northwest Laboratory (PNL), FEMP is developing a fuel-neutral approach for identifying, evaluating, and acquiring all cost-effective energy projects at federal installations; this procedure is entitled the Federal Energy Decision Screening (FEDS) system. Through a cooperative program between FEMP and the Army Forces Command (FORSCOM) for providing technical assistance to FORSCOM installations, PNL has been working with the Fort Lewis Army installation to develop the FEDS procedure. The natural gas and fuel oil assessment contained in this report was preceded with an assessment of electric energy usage that was used to implement a cofunded program between Fort Lewis and Tacoma Public Utilities to improve the efficiency of the Fort`s electric-energy-using systems. This report extends the assessment procedure to the systems using natural gas and fuel oil to provide a baseline of consumption and an estimate of the energy-efficiency potential that exists for these two fuel types at Fort Lewis. The baseline is essential to segment the end uses that are targets for broad-based efficiency improvement programs. The estimated fossil-fuel efficiency resources are estimates of the available quantities of conservation for natural gas, fuel oils {number_sign}2 and {number_sign}6, and fuel-switching opportunities by level of cost-effectiveness. The intent of the baseline and efficiency resource estimates is to identify the major efficiency resource opportunities and not to identify all possible opportunities; however, areas of additional opportunity are noted to encourage further effort.

  10. Secondary natural gas recovery: Targeted applications for infield reserve growth in midcontinent reservoirs, Boonsville Field, Fort Worth Basin, Texas. Topical report, May 1993--June 1995

    SciTech Connect (OSTI)

    Hardage, B.A.; Carr, D.L.; Finley, R.J.; Tyler, N.; Lancaster, D.E.; Elphick, R.Y.; Ballard, J.R.

    1995-07-01T23:59:59.000Z

    The objectives of this project are to define undrained or incompletely drained reservoir compartments controlled primarily by depositional heterogeneity in a low-accommodation, cratonic Midcontinent depositional setting, and, afterwards, to develop and transfer to producers strategies for infield reserve growth of natural gas. Integrated geologic, geophysical, reservoir engineering, and petrophysical evaluations are described in complex difficult-to-characterize fluvial and deltaic reservoirs in Boonsville (Bend Conglomerate Gas) field, a large, mature gas field located in the Fort Worth Basin of North Texas. The purpose of this project is to demonstrate approaches to overcoming the reservoir complexity, targeting the gas resource, and doing so using state-of-the-art technologies being applied by a large cross section of Midcontinent operators.

  11. California’s North Coast Fishing Communities Historical Perspective and Recent Trends: Fort Bragg/Noyo Harbor Fishing Community Profile

    E-Print Network [OSTI]

    Pomeroy, Caroline; Thomson, Cynthia J.; Stevens, Melissa M.

    2011-01-01T23:59:59.000Z

    3/29/10. Fort Bragg/Noyo Harbor Fishing Community ProfileHarbor Fishing Community Profile Henning. 1966. FeasibilityVaccaro. 2007. Community Profiles for West Coast and North

  12. Building America Whole-House Solutions for New Home: Fort Devens: Cold Climate Market-Rate Townhomes

    Broader source: Energy.gov [DOE]

    Fort Devens: Cold Climate Market-Rate Townhomes Targeting HERS Index of 40, Harvard, Massachusetts (Fact Sheet), Building America Case Study: Efficient Solutions for New and Existing Homes, Building Technologies Office (BTO)

  13. Renewable Energy Development on Fort Mojave Reservation Feasiblity Study

    SciTech Connect (OSTI)

    Russell Gum, ERCC analytics LLC

    2008-03-17T23:59:59.000Z

    The Ft. Mojave tribe, whose reservation is located along the Colorado River in the states of Arizona, California, and Nevada near the point where all three states meet, has a need for increased energy supplies. This need is a direct result of the aggressive and successful economic development projects undertaken by the tribe in the last decade. While it is possible to contract for additional energy supplies from fossil fuel sources it was the desire of the tribal power company, AHA MACAV Power Service (AMPS) to investigate the feasibility and desirability of producing power from renewable sources as an alternative to increased purchase of fossil fuel generated power and as a possible enterprise to export green power. Renewable energy generated on the reservation would serve to reduce the energy dependence of the tribal enterprises on off reservation sources of energy and if produced in excess of reservation needs, add a new enterprise to the current mix of economic activities on the reservation. Renewable energy development would also demonstrate the tribe’s support for improving environmental quality, sustainability, and energy independence both on the reservation and for the larger community.

  14. Nondestructive examination of 51 fuel and reflector elements from Fort St. Vrain Core Segment 1

    SciTech Connect (OSTI)

    Miller, C.M.; Saurwein, J.J.

    1980-12-01T23:59:59.000Z

    Fifty-one fuel and reflector elements irradiated in core segment 1 of the Fort St. Vrain High-Temperature Gas-Cooled Reactor (HTGR) were inspected dimensionally and visually in the Hot Service Facility at Fort St. Vrain in July 1979. Time- and volume-averaged graphite temperatures for the examined fuel elements ranged from approx. 400/sup 0/ to 750/sup 0/C. Fast neutron fluences varied from approx. 0.3 x 10/sup 25/ n/m/sup 2/ to 1.0 x 10/sup 25/ n/m/sup 2/ (E > 29 fJ)/sub HTGR/. Nearly all of the examined elements shrank in both axial and radial dimensions. The measured data were compared with strain and bow predictions obtained from SURVEY/STRESS, a computer code that employs viscoelastic beam theory to calculate stresses and deformations in HTGR fuel elements.

  15. Fort Lewis natural gas and fuel oil energy baseline and efficiency resource assessment

    SciTech Connect (OSTI)

    Brodrick, J.R. (USDOE, Washington, DC (United States)); Daellenbach, K.K.; Parker, G.B.; Richman, E.E.; Secrest, T.J.; Shankle, S.A. (Pacific Northwest Lab., Richland, WA (United States))

    1993-02-01T23:59:59.000Z

    The mission of the US Department of Energy (DOE) Federal Energy Management Program (FEMP) is to lead the improvement of energy efficiency and fuel flexibility within the federal sector. Through the Pacific Northwest Laboratory (PNL), FEMP is developing a fuel-neutral approach for identifying, evaluating, and acquiring all cost-effective energy projects at federal installations; this procedure is entitled the Federal Energy Decision Screening (FEDS) system. Through a cooperative program between FEMP and the Army Forces Command (FORSCOM) for providing technical assistance to FORSCOM installations, PNL has been working with the Fort Lewis Army installation to develop the FEDS procedure. The natural gas and fuel oil assessment contained in this report was preceded with an assessment of electric energy usage that was used to implement a cofunded program between Fort Lewis and Tacoma Public Utilities to improve the efficiency of the Fort's electric-energy-using systems. This report extends the assessment procedure to the systems using natural gas and fuel oil to provide a baseline of consumption and an estimate of the energy-efficiency potential that exists for these two fuel types at Fort Lewis. The baseline is essential to segment the end uses that are targets for broad-based efficiency improvement programs. The estimated fossil-fuel efficiency resources are estimates of the available quantities of conservation for natural gas, fuel oils [number sign]2 and [number sign]6, and fuel-switching opportunities by level of cost-effectiveness. The intent of the baseline and efficiency resource estimates is to identify the major efficiency resource opportunities and not to identify all possible opportunities; however, areas of additional opportunity are noted to encourage further effort.

  16. Mobility 2030: The Metropolitan Transportation Plan for the Dallas-Fort Worth Area 2009 Amendment

    E-Print Network [OSTI]

    North Central Texas Council of Governments

    2009-04-09T23:59:59.000Z

    the airports via DART light rail. DCTA will connect to the system in Carrollton. ? Review surface access to aviation and related changes over time. St udy alternative access and congestion scenarios at commercial airports based on alternative air travel... Dallas/Fort Worth International Airport Kathryn Wilemon Councilm e m b e r, City of Arlingt on Michael Morris, P.E. Director of Transportation, NCTC OG Surface Transportation Technical Committee Jim Sparks, Chair City of Grand Prairi e...

  17. Annual Radiological Environmental Monitoring Program Report for the Fort St. Vrain Independent Spent Fuel Storage Installation

    SciTech Connect (OSTI)

    Hall, Gregory Graham; Newkirk, Jay Ronald; Borst, Frederick Jon

    2002-02-01T23:59:59.000Z

    This report presents the results of the 2001 Radiological Environmental Monitoring Program conducted in accordance with 10 CFR 72.44 for the Fort St. Vrain Independent Spent Fuel Storage Installation. A description of the facility and the monitoring program is provided. The results of monitoring the predominant radiation exposure pathway, direct and scattered radiation exposure, indicate the facility operation has not contributed to any increase in the estimated maximum potential dose commitment to the general public.

  18. Methodology for the evaluation of a 4000-home geothermal heat pump retrofit at Fort Polk, Louisiana

    SciTech Connect (OSTI)

    Hughes, P.J.; Shonder, J.A.; White, D.L.; Huang, H.L.

    1998-03-01T23:59:59.000Z

    The US Army and a private energy service company are developing a comprehensive energy efficiency project to upgrade the family housing at Fort Polk, Louisiana. The project includes converting the space conditioning systems of more than 4,000 housing units to geothermal (or ground-source) heat pumps (GHPs). This interim report describes the methodology of the evaluation associated with this project, including the field monitoring that has been conducted at the base.

  19. Energy efficiency campaign for residential housing at the Fort Lewis army installation

    SciTech Connect (OSTI)

    AH McMakin; RE Lundgren; EL Malone

    2000-02-23T23:59:59.000Z

    In FY1999, Pacific Northwest National Laboratory conducted an energy efficiency campaign for residential housing at the Fort Lewis Army Installation near Tacoma, Washington. Preliminary weather-corrected calculations show energy savings of 10{percent} from FY98 for energy use in family housing. This exceeded the project's goal of 3{percent}. The work was funded by the U.S. DOEs Federal Energy Management Program (FEMP), Office of Energy Efficiency and Renewable Energy. The project adapted FEMP's national ``You Have the Power Campaign'' at the local level, tailoring it to the military culture. The applied research project was designed to demonstrate the feasibility of tailored, research-based strategies to promote energy conservation in military family housing. In contrast to many energy efficiency efforts, the campaign focused entirely on actions residents could take in their own homes, as opposed to technology or housing upgrades. Behavioral change was targeted because residents do not pay their own utility bills; thus other motivations must drive personal energy conservation. This campaign augments ongoing energy savings from housing upgrades carried out by Fort Lewis. The campaign ran from September 1998 through August 1999. The campaign strategy was developed based on findings from previous research and on input from residents and officials at Fort Lewis. Energy use, corrected to account for weather differences, was compared with the previous year's use. Survey responses from 377 of Fort Lewis residents of occupied housing showed that the campaign was moderately effective in promoting behavior change. Of those who were aware of the campaign, almost all said they were now doing one or more energy-efficient things that they had not done before. Most people were motivated by the desire to do the right thing and to set a good example for their children. They were less motivated by other factors.

  20. The justification of budget requests utilizing a grounds resource inventory at the Fort Worth Botanic Garden

    E-Print Network [OSTI]

    Powers, Vivian Lee

    1989-01-01T23:59:59.000Z

    TEXAS ARM UNIVERSITY LIBRARY Record of Study THE JUST1FICATION OF BUDGET REQUESTS UTILIZING A GROUNDS RESOURCE INVENTORY AT THE FORT WORTH BOTANIC GARDEN A PROFESSIONAL PAPER by Vivian Lee Powers Submitted to the College of Agriculture... budget requests. Anaheim City Park's Superintendent Chris Jarvi knew that when the new Riverdaie Park was completed it would require him to hire 1. 3 addition maintenance workers. (I) He could also prove this to the budget analysts, city manager...

  1. Beyond bolts : architectural details, construction, meaning

    E-Print Network [OSTI]

    Weber, Peter Dominic

    1991-01-01T23:59:59.000Z

    An architectural Detail is a small piece of the whole, yet it has the power to characterize and define the entire building. Details tell us what a building is; they are fundamental to the life and personality of a space. ...

  2. Energy saving potential of residential HVAC options at Fort Irwin, California

    SciTech Connect (OSTI)

    Hadley, D.L.; Stucky, D.J.

    1995-03-01T23:59:59.000Z

    The Pacific Northwest Laboratory (PNL) evaluated heating and cooling system options for existing family housing at Fort Irwin, California. The purpose of this work was to quantify the energy conservation potential of alternative system types and to identify the most cost-effective technology available. The conventional residential heating/cooling systems at Fort Irwin are separate propane forced-air furnaces and central air conditioners. The options examined included air- and ground-source heat pumps, a natural gas furnace with central air conditioning, and a natural-gas-fired heat pump. The most cost-effective technology applicable to Fort Irwin was found to be the high-efficiency ground-source heat pumps. If all conventional units were replaced immediately, the net energy savings would be 76,660 MBtu (80.9 TJ) per year and a reduction in electrical demand of approximately 15,000 kW-month. The initial investment for implementing this technology would be approximately $7.1 million, with a savings-to-investment ratio of 1.74.

  3. Federal Energy Decision Screening (FEDS) process at Fort Drum, New York

    SciTech Connect (OSTI)

    Dixon, D.R.; Daellenbach, K.K. [Pacific Northwest Lab., Richland, WA (United States); Rowley, S.E. [Directorate of Engineering & Housing, Ft. Drum, NY (United States); Gillespie, A.H. [Army Forces Command, Ft. McPherson, GA (United States)

    1993-10-01T23:59:59.000Z

    The federal energy manager has been directed by the Comprehensive Energy Policy Act of 1992 (EPAct) to reduce energy consumption by 20% from 1985 levels, by the year 2000. However, the tools and funding to capture this resource in a cost-effective manner have not been provided. In an effort to assist federal agencies in meeting EPAct requirements, the Pacific Northwest Laboratory (PNL) has been tasked by the US Army Forces Command (FORSCOM) to identify, evaluate, and acquire all cost-effective energy projects at selected federal facilities. PNL has developed and applied the Federal Energy Decision Screening (FEDS) methodology at the Fort Drum FORSCOM facility near Watertown, New York. The FEDS methodology is a systematic approach to evaluating energy opportunities that result in a roadmap to significantly reduce energy use in a planned, rational, cost justified fashion over a 5 to 10 year period. At Fort Drum, the net present value (NPV) of the installed cost of all cost-effective energy resource opportunities (EROS) is over $16 million (1992 $). The NPV of the savings associated with this investment is nearly $47 million (1992 $), for an overall NPV of approximately $31 million. By implementing all the cost-effective EROS, Fort Drum will reduce annual energy use by over 230,000 MBtu, or 15%. Annual energy expenditures will decrease by over $2.4 million, or a 20% reduction.

  4. Improving alternative fuel utilization: detailed kinetic combustion...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Improving alternative fuel utilization: detailed kinetic combustion modeling & experimental testing Salvador Aceves, Daniel Flowers, Bill Pitz, Charlie Westbrook, Emma Silke,...

  5. Reversible micromachining locator

    DOE Patents [OSTI]

    Salzer, L.J.; Foreman, L.R.

    1999-08-31T23:59:59.000Z

    This invention provides a device which includes a locator, a kinematic mount positioned on a conventional tooling machine, a part carrier disposed on the locator and a retainer ring. The locator has disposed therein a plurality of steel balls, placed in an equidistant position circumferentially around the locator. The kinematic mount includes a plurality of magnets which are in registry with the steel balls on the locator. In operation, a blank part to be machined is placed between a surface of a locator and the retainer ring (fitting within the part carrier). When the locator (with a blank part to be machined) is coupled to the kinematic mount, the part is thus exposed for the desired machining process. Because the locator is removably attachable to the kinematic mount, it can easily be removed from the mount, reversed, and reinserted onto the mount for additional machining. Further, the locator can likewise be removed from the mount and placed onto another tooling machine having a properly aligned kinematic mount. Because of the unique design and use of magnetic forces of the present invention, positioning errors of less than 0.25 micrometer for each machining process can be achieved. 7 figs.

  6. Reversible micromachining locator

    DOE Patents [OSTI]

    Salzer, Leander J. (Los Alamos, NM); Foreman, Larry R. (Los Alamos, NM)

    1999-01-01T23:59:59.000Z

    This invention provides a device which includes a locator, a kinematic mount positioned on a conventional tooling machine, a part carrier disposed on the locator and a retainer ring. The locator has disposed therein a plurality of steel balls, placed in an equidistant position circumferentially around the locator. The kinematic mount includes a plurality of magnets which are in registry with the steel balls on the locator. In operation, a blank part to be machined is placed between a surface of a locator and the retainer ring (fitting within the part carrier). When the locator (with a blank part to be machined) is coupled to the kinematic mount, the part is thus exposed for the desired machining process. Because the locator is removably attachable to the kinematic mount, it can easily be removed from the mount, reversed, and reinserted onto the mount for additional machining. Further, the locator can likewise be removed from the mount and placed onto another tooling machine having a properly aligned kinematic mount. Because of the unique design and use of magnetic forces of the present invention, positioning errors of less than 0.25 micrometer for each machining process can be achieved.

  7. 2011-12 Expenditures Req # Amount Category Vendor Detail Event Location Event

    E-Print Network [OSTI]

    Advanced Business Systems Service Contract for copier n/a n/a n/a COGS 702575 $47 Expense GovConnection TV

  8. Description of Axial Detail for ROK Fuel

    SciTech Connect (OSTI)

    Trellue, Holly R [Los Alamos National Laboratory; Galloway, Jack D [Los Alamos National Laboratory

    2012-04-20T23:59:59.000Z

    For the purpose of NDA simulations of the ROK fuel assemblies, we have developed an axial burnup distribution to represent the pins themselves based on gamma scans of rods in the G23 assembly. For the purpose of modeling the G23 assembly (both at ORNL and LANL), the pin-by-pin burnup map as simulated by ROK is being assumed to represent the radial burnup distribution. However, both DA and NDA results indicate that this simulated estimate is not 100% correct. In particular, the burnup obtained from the axial gamma scan of 7 pins does not represent exactly the same 'average' pin burnup as the ROK simulation. Correction for this discrepancy is a goal of the well-characterized assembly task but will take time. For now, I have come up with a correlation for 26 axial points of the burnup as obtained by gamma scans of 7 different rods (C13, G01, G02, J11, K10, L02, and M04, neglecting K02 at this time) to the average burnup given by the simulation for each of the rods individually. The resulting fraction in each axial zone is then averaged for the 7 different rods so that it can represent every fuel pin in the assembly. The burnup in each of the 26 axial zones of rods in all ROK assemblies will then be directly adjusted using this fraction, which is given in Table 1. Note that the gamma scan data given by ROK for assembly G23 included a length of {approx}3686 mm, so the first 12 mm and the last 14 mm were ignored to give an actual rod length of {approx}366 cm. To represent assembly F02 in which no pin-by-pin burnup distribution is given by ROK, we must model it using infinitely-reflected geometry but can look at the effects of measuring in different axial zones by using intermediate burnup files (i.e. smaller burnups than 28 GWd/MTU) and determining which axial zone(s) each burnup represents. Details for assembly F02 are then given in Tables 2 and 3, which is given in Table 1 and has 44 total axial zones to represent the top meter in explicit detail in addition to the other 26 zones. Note that the MCNP files for F02 were created using the Monte Carlo burnup linkage code Monteburns, which saves MCNP input files with detailed compositions as a function of burnup. The 'intermediate burnup files' produced for F02 include a cooling time of 27 years. The axial location of 5 spacers was also included in the ROK F02 assembly in which each spacer contained a length of 3.81 cm. Note that due to the nature of Monteburns, which was run in a special fashion for this problem, the step number increments after the 27 year decay, so the second column of Table 2 refers to the step number that should be used in the Monteburns files.

  9. Reversible micromachining locator

    DOE Patents [OSTI]

    Salzer, Leander J. (Los Almos, NM); Foreman, Larry R. (late of Los Alamos, NM)

    2002-01-01T23:59:59.000Z

    A locator with a part support is used to hold a part onto the kinematic mount of a tooling machine so that the part can be held in or replaced in exactly the same position relative to the cutting tool for machining different surfaces of the part or for performing different machining operations on the same or different surfaces of the part. The locator has disposed therein a plurality of steel balls placed at equidistant positions around the planar surface of the locator and the kinematic mount has a plurality of magnets which alternate with grooves which accommodate the portions of the steel balls projecting from the locator. The part support holds the part to be machined securely in place in the locator. The locator can be easily detached from the kinematic mount, turned over, and replaced onto the same kinematic mount or another kinematic mount on another tooling machine without removing the part to be machined from the locator so that there is no need to touch or reposition the part within the locator, thereby assuring exact replication of the position of the part in relation to the cutting tool on the tooling machine for each machining operation on the part.

  10. Crump Geyser: High Precision Geophysics & Detailed Structural...

    Broader source: Energy.gov (indexed) [DOE]

    Crump Geyser: High Precision Geophysics & Detailed Structural Exploration & Slim Well Drilling John Casteel Nevada Geothermal Power Co. Validation of Innovative Exploration...

  11. Fort Huachuca Water Awareness Program: Best Management Practice Case Study #2: Information and Education Programs, Federal Energy Management Program (FEMP) (Brochure)

    SciTech Connect (OSTI)

    Not Available

    2009-12-01T23:59:59.000Z

    Case study overview of the U.S. Army Fort Huachuca water awareness practice as part of FEMP's water efficiency best management practice series.

  12. Locating Heat Recovery Opportunities 

    E-Print Network [OSTI]

    Waterland, A. F.

    1981-01-01T23:59:59.000Z

    Basic concepts of heat recovery are defined as they apply to the industrial community. Methods for locating, ranking, and developing heat recovery opportunities are presented and explained. The needs for useful heat 'sinks' are emphasized as equal...

  13. Locating Heat Recovery Opportunities

    E-Print Network [OSTI]

    Waterland, A. F.

    1981-01-01T23:59:59.000Z

    Basic concepts of heat recovery are defined as they apply to the industrial community. Methods for locating, ranking, and developing heat recovery opportunities are presented and explained. The needs for useful heat 'sinks' are emphasized as equal...

  14. Geothermal heat pump energy savings performance contract at Fort Polk, LA: Lessons learned

    SciTech Connect (OSTI)

    Shonder, J.A.; Hughes, P.J. [Oak Ridge National Lab., TN (United States); Gordon, R. [Applied Energy Management Techniques, Corvallis, OR (United States); Giffin, T. [SAIC/The Fleming Group, East Syracuse, NY (United States)

    1997-08-01T23:59:59.000Z

    At Fort Polk, LA the space conditioning systems of 4,003 military family housing units have been converted to geothermal heat pumps (GHP) under an energy savings performance contract (ESPC). At the same time, other efficiency measures, such as compact fluorescent lights (CFLs), low-flow shower heads, and attic insulation, were installed. An independent evaluation of the Fort Polk ESPC was carried out. Findings indicate that the project has resulted in a 25.6 million kWh savings in electrical energy use, or 32.4% of the pre-retrofit electrical consumption in family housing, for a typical meteorological year. Peak electrical demand has also been reduced by 6,541 kW, which is 39.6% of the pre-retrofit peak demand. Natural gas savings are about 260,000 therms per year. In addition, the ESPC has allowed the Army to effectively cap its future expenditures for family housing HVAC maintenance at about 77% of its previous costs. Given these successful results, the Fort Polk ESPC can provide a model for other ESPCs in both the public and the private sectors. The purpose of this paper is to outline the method by which the ESPC was engineered and implemented, both from the standpoint of the facility owner (the US Army) and the energy services company (ESCO) which is carrying out the contract. The lessons learned from this experience should be useful to other owners, ESCOs and investors in the implementation of future ESPCs. It should be noted that the energy savings presented in this document are the apparent energy savings observed in the monitored data, and are not to be confused with the contracted energy savings used as the basis for payments. To determine the contracted energy savings, the apparent energy savings may require adjustments for such things as changes in indoor temperature performance criteria, additions of ceiling fans, and other factors.

  15. Short range radio locator system

    DOE Patents [OSTI]

    McEwan, Thomas E. (Livermore, CA)

    1996-01-01T23:59:59.000Z

    A radio location system comprises a wireless transmitter that outputs two megahertz period bursts of two gigahertz radar carrier signals. A receiver system determines the position of the transmitter by the relative arrival of the radar bursts at several component receivers set up to have a favorable geometry and each one having a known location. One receiver provides a synchronizing gating pulse to itself and all the other receivers to sample the ether for the radar pulse. The rate of the synchronizing gating pulse is slightly offset from the rate of the radar bursts themselves, so that each sample collects one finely-detailed piece of information about the time-of-flight of the radar pulse to each receiver each pulse period. Thousands of sequential pulse periods provide corresponding thousand of pieces of information about the time-of-flight of the radar pulse to each receiver, in expanded, not real time. Therefore the signal processing can be done with relatively low-frequency, inexpensive components. A conventional microcomputer is then used to find the position of the transmitter by geometric triangulation based on the relative time-of-flight information.

  16. Fort Devens: Cold Climate, Energy-Efficient, Market-Rate Townhomes

    SciTech Connect (OSTI)

    Zoeller, W.; Slattery, M.; Grab, J.

    2013-08-01T23:59:59.000Z

    In 2009, Mass Development issued an RFQ and subsequent RFP for teams to develop moderately priced high-efficiency homes on two sites within the Devens Regional Enterprise Zone. MassDevelopment, a Massachusetts agency that owns the Devens site (formerly Fort Devens Army Base, in Harvard, Massachusetts), set a goal of producing a replicable example of current and innovative sustainable building practices with a near-zero energy potential. Metric Development, as primary developer and construction manager, formed one of the successful teams that included CARB and Cambridge Seven Architects (C7A).

  17. Baseline Report for the Fort Hood Army Base: Sept. 1, 2001 To Aug. 31, 2002

    E-Print Network [OSTI]

    Haberl, J. S.; Baltazar, J. C.; Sung, Y. H.; Claridge, D. E.; Turner, W. D.

    ESL-TR-02/12-02 BASELINE REPORT FOR THE FORT HOOD ARMY BASE: SEPT. 1, 2001 TO AUG. 31, 2002 A Research Project for the U.S. Army C.E.R.L. and the Ft. Hood Energy Office Jeff S. Haberl, Ph.D., P.E. Juan...-Carlos Baltazar Cervantes Yong Hoon Sung David E. Claridge, Ph.D., P.E. W. Dan Turner, Ph.D., P.E. December 2002 ENERGY SYSTEMS LABORATORY Texas Engineering Experiment Station Texas A&M University System FT. HOOD BASELINE...

  18. The Role of Occupant Behavior in Achieving Net Zero Energy: A Demonstration Project at Fort Carson

    SciTech Connect (OSTI)

    Judd, Kathleen S.; Sanquist, Thomas F.; Zalesny, Mary D.; Fernandez, Nicholas

    2013-09-30T23:59:59.000Z

    This study, sponsored by the U.S. General Services Administration’s Office of Federal High-Performance Green Buildings, aimed to understand the potential for institutional and behavioral change to enhance the performance of buildings, through a demonstration project with the Department of Defense in five green buildings on the Fort Carson, Colorado, Army base. To approach this study, the research team identified specific occupant behaviors that had the potential to save energy in each building, defined strategies that might effectively support behavior change, and implemented a coordinated set of actions during a three-month intervention.

  19. Geothermal Direct Use Feasibility Study on the Fort Bidwell Indian Reservation

    SciTech Connect (OSTI)

    Dale Merrick

    2007-04-20T23:59:59.000Z

    The Fort Bidwell Indian Reservation (FBIR) is rich in renewable energy resources. Development of its geothermal resources has the potential to profoundly affect the energy and economic future of the FBIC. Geothermal energy can contribute to making the reservation energy self-sufficient and, potentially, an energy exporter. The feasibility study assessed the feasibility of installing a geothermal district heating system to provide low-cost, efficient heating of existing and planned residences, community buildings and water, using an existing geothermal well, FB-3.

  20. Lincoln-Fort Rice, North Dakota: Energy Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov YouKizildere I Geothermal Pwer Plant Jump to:Landowners and WindLighting ControlWyoming:Rhode Island: EnergyLincoln-Fort

  1. Fort Collins, Colorado on Track to Net Zero | Department of Energy

    Office of Environmental Management (EM)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 1112011 Strategic2 OPAM Flash2011-12 OPAM Revised DOEDepartment of EnergyUpdated FebruaryFort

  2. 2-M Probe At Fort Bliss Area (DOE GTP) | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are beingZealand Jump to:Ezfeedflag JumpID-fTriWildcat 1 Wind ProjectsourceInformation 2-M Probe At DesertFort

  3. Honours APPLICATION UG 2. CONTACT DETAILS

    E-Print Network [OSTI]

    Du, Jie

    of Sydney student number: Citizenship: Australian citizen New Zealand citizen Australian permanent resident.e. not an Australian citizen, permanent resident or New Zealand citizen) Title: Gender: Family Name: Given names school/unit/discipline for further details. #12;4. HONOURS DETAILS Majors in science subject area(s) (if

  4. Derivation of Locational Marginal Prices for Restructured Wholesale Power Markets

    E-Print Network [OSTI]

    Tesfatsion, Leigh

    Derivation of Locational Marginal Prices for Restructured Wholesale Power Markets Haifeng Liu restructured wholesale power markets, the detailed derivation of LMPs as actually used in industry practice Operator (MISO). Keywords: Locational marginal pricing, wholesale power market, AC optimal power flow, DC

  5. Fort Rucker

    Office of Environmental Management (EM)

    by: FEDERAL UTILITY PARTNERSHIP WORKING GROUP SEMINAR May 7 - 8, 2014 Virginia Beach, VA UESC Program Case Study - Ft. Rucker * Contract Value 16.6MTotal Project Lifetime Savings...

  6. Seeing Savings from an ESPC Project in Fort Polk's Utility Bills

    SciTech Connect (OSTI)

    Shonder, J.A.

    2005-03-08T23:59:59.000Z

    Federal agencies have implemented many energy efficiency projects over the years with direct funding or alternative financing vehicles such as energy savings performance contracts (ESPCs). While it is generally accepted that these projects save energy and costs, the savings are usually not obvious in the utility bills. This is true for many valid technical reasons, even when savings are verified in other ways to the highest degree of certainty. However, any perceived deficiency in the evidence for savings is problematic when auditors or other observers evaluate the outcome of energy projects and the achievements of energy management programs. This report discusses under what circumstances energy savings should or should not be evident in utility bills. In the special case of a large ESPC project at the Army's Fort Polk, the analysis of utility bills carried out by the authors does unequivocally confirm and quantify savings. The data requirements and methods for arriving at definitive answers through utility bill analysis are demonstrated in our discussion of the Fort Polk project. The following paragraphs address why the government generally should not expect to see savings from ESPC projects in their utility bills. We also review lessons learned and best practices for measurement and verification (M&V) that can assure best value for the government and are more practical, straightforward, and cost-effective than utility bill analysis.

  7. Installation-wide energy-conservation demonstration at Fort McClellan, Alabama. Final report

    SciTech Connect (OSTI)

    Windingland, L.M.; Lilly, B.P.; Shonder, J.A.; Underwood, D.M.; Augustine, L.J.

    1988-11-01T23:59:59.000Z

    The objective of the installation-wide energy conservation demonstration at Fort McClellan, AL, was to evaluate the effectiveness of applying available energy-conservation technologies and techniques to produce significant and predictable reductions in energy use and cost. Five major areas of energy conservation were identified and investigated: (1) pressure reduction in district-steam-heating systems; (2) reduction of outdoor air in heating, ventilation, and air-conditioning (HVAC) systems; (3) replacement of oversized and inefficient motors in HVAC systems; (4) reduction of outdoor air infiltration in family housing; and (5) combustion optimization of gas-fired heating equipment. Other areas of investigation included radio-controlled exterior lighting, and temperature reduction in the high-temperature hot-water system. Each conservation project was evaluated on a small scale to verify energy savings before it was implemented. An energy-information management system was developed to maintain annual consumption data for each building. The system provides immediate feedback on energy use so managers can make correct decisions on conservation measures. The energy conservation programs implemented at Fort McClellan contributed to the 14% reduction in baseline (weather independent) energy consumption from FY84 to FY86. These programs have wide applicability to other U.S. Army installations. This research has also shown the importance of preliminary, small-scale testing of energy-conservation programs before implementation.

  8. Depositional history of the Mississippian Ullin and Fort Payne Formations in the Illinois Basin

    SciTech Connect (OSTI)

    Lasemi, Z.; Treworgy, J.D.; Norby, R.D. (Illinois State Geological Survey, Champaign, IL (United States))

    1994-04-01T23:59:59.000Z

    Field and subsurface data suggest that the mid-Mississippian Ullin Limestone in the Illinois Basin is composed of coalesced Waulsortian-type mounds and porous bryozoan-dominated buildups. Waulsortian mounds in the basin contain a lime mudstone to wackestone core that is flanked and capped by in situ porous bryozoan bafflestone or transported crinoidal-bryozoan packstone and grainstone. The mound core facies appear to be most common in the lower part of the Ullin and is thicker in a deeper outer-ramp setting. Shoreward and up-section (upper part of the outer-ramp through mid-ramp setting), the core facies is generally thinner, while the flanking and capping facies are thicker. Isopachous maps of the Ullin and Fort Payne suggest the presence of several large areas of thick carbonate buildups (Ullin) surrounded by a deep-water, sub-oxic environment (Fort Payne) in the Illinois Basin. Progradation of these buildups and associated facies resulted in a shallower ramp setting during deposition of the upper Ullin. Storm-generated carbonate sandwaves became widespread on this ramp. Sandwaves were mobile and for the most part unfavorable sites for further development of thick mud mounds and/or in situ bryozoan buildups. However, isolated mounds and flanking buildups are present in the upper part of the Ullin, and, together with the sandwaves, formed an irregular topography that led to the development of oolitic grainstone shoals during deposition of the overlying Salem Limestone.

  9. Simulating plant motion with levels of detail

    E-Print Network [OSTI]

    Flannery, Rebecca Lynn

    2013-02-22T23:59:59.000Z

    SIMULATING PLANT MOTION WITH LEVELS OF DETAIL A Senior Honors Thesis by REBECCA LYNN FLANNERY Submitted to the Office of Honors Programs k. Academic Scholarships Texas AkM University in partial fulfillment of the requirements... of the UNIVERSITY UNDERGRADUATE RESEARCH FELLOWS April 2003 Group: Engineering & Physics I SIMULATING PLANT MOTION WITH LEVELS OF DETAIL A Senior Honors Thesis by REBECCA LYNN FLANNERY Submitted to the Office of Honors Programs & Academic Scholarships...

  10. Electric current locator

    DOE Patents [OSTI]

    King, Paul E. (Corvallis, OR); Woodside, Charles Rigel (Corvallis, OR)

    2012-02-07T23:59:59.000Z

    The disclosure herein provides an apparatus for location of a quantity of current vectors in an electrical device, where the current vector has a known direction and a known relative magnitude to an input current supplied to the electrical device. Mathematical constants used in Biot-Savart superposition equations are determined for the electrical device, the orientation of the apparatus, and relative magnitude of the current vector and the input current, and the apparatus utilizes magnetic field sensors oriented to a sensing plane to provide current vector location based on the solution of the Biot-Savart superposition equations. Description of required orientations between the apparatus and the electrical device are disclosed and various methods of determining the mathematical constants are presented.

  11. Optimal fault location

    E-Print Network [OSTI]

    Knezev, Maja

    2009-05-15T23:59:59.000Z

    are triggered. Protection system consisting of protection relays and circuit breakers (CBs) will operate in order to de-energize faulted line. Different Intelligent Electronic Devices (IEDs) located in substations for the purpose of monitoring... in the control center by an operator who will mark fault event in a spreadsheet and inform other staff responsible for dealing with fault analysis and repair such as protection group or maintenance respectively. Protective relaying staff will be ready...

  12. Optimal fault location

    E-Print Network [OSTI]

    Knezev, Maja

    2008-10-10T23:59:59.000Z

    are triggered. Protection system consisting of protection relays and circuit breakers (CBs) will operate in order to de-energize faulted line. Different Intelligent Electronic Devices (IEDs) located in substations for the purpose of monitoring... in the control center by an operator who will mark fault event in a spreadsheet and inform other staff responsible for dealing with fault analysis and repair such as protection group or maintenance respectively. Protective relaying staff will be ready...

  13. Alternative Fueling Station Locator

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home PageStation LocationsGeneseeValleyPerformance

  14. Alternative Fueling Station Locator

    Alternative Fuels and Advanced Vehicles Data Center [Office of Energy Efficiency and Renewable Energy (EERE)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels Data Center Home PageStation LocationsGeneseeValleyPerformance

  15. Final Exam Location and Time

    E-Print Network [OSTI]

    Final Exam Location and Time. Math 162 Fall 2001. Date: Wednesday December 12, 2001. Time: 7:00 pm -9:00 pm. Location: Lambert Fieldhouse ...

  16. Final Exam Location and Time

    E-Print Network [OSTI]

    Final Exam Location and Time. Math 161 Fall 2001. Date: Friday December 14, 2001. Time: 8:00 am -10:00 am. Location: Lambert Fieldhouse ...

  17. U.S. ARMY CORPS OF ENGINEERS HURRICANE SANDY COASTAL MANAGEMENT DIVISION 130 Wainwright Dr. Fort Hamilton, NY 11209

    E-Print Network [OSTI]

    US Army Corps of Engineers

    U.S. ARMY CORPS OF ENGINEERS ­ HURRICANE SANDY COASTAL MANAGEMENT DIVISION 130 Wainwright Dr. Fort,000 miles of coastline within the North Atlantic Division that were affected by Hurricane Sandy. The study response to the devastation in the wake of Hurricane Sandy represents a need to address as a regional

  18. GROUND PENETRATING RADAR STUDY OF THE CHEKO LAKE AREA (SIBERIA) M.Pipan, L.Baradello, E.Forte

    E-Print Network [OSTI]

    Curci, Gabriele

    .Forte University of Trieste, Department of Geological, Environmental and Marine Sciences via Weiss 1, 34127 Trieste, Italy pipan@univ.trieste.it barad@geops15.univ.trieste.it ema@geops15.univ.trieste.it L.Gasperini, E of the Exploration Geophysics Group of the University of Trieste (Italy) in the framework of a scientific cooperation

  19. Quality site seasonal report, Fort Devens Launderette, SFBP (Solar in Federal Buildings Program) 1751, December 1984 through June 1985

    SciTech Connect (OSTI)

    Logee, T.L.

    1987-10-15T23:59:59.000Z

    The active solar Domestic Hot Water (DHW) system at the Fort Devens Launderette was designed and constructed as part of the Solar in Federal Buildings Program (SFBP). This retrofitted system was one of eight systems selected for quality monitoring. The purpose of this monitoring effort was to document the performance of quality state-of-the-art solar systems in large federal buildings. The launderette is part of the Post Exchange complex at the Fort Devens Army Post in Fort Devens, Massachusetts. The solar system preheats hot water for the coin operated laundry which has an estimated 25,000 customers per year. There are 108 collector panels comprising the 2563-square foot collector array. Collected solar energy is stored in a 3800-gallon tank. Propylene glycol is used to protect the solar array from freezing. Two immersed heat exchangers provide heat transfer from the propylene glycol to directly heat the DHW supply water in the storage tank. Auxiliary energy is supplied by gas and oil boilers. This solar system can be considered one of a kind and as such is a prototype. The lessons learned from building and operating this system should be used to correct design deficiencies and improve the performance of future solar systems for this application. Highlights of the system performance at the Fort Devens Launderette solar system during the December 1984 through June 1985 monitoring period are presented in this report.

  20. Development of a Monitoring and Verification (M&V) Plan and Baseline for the Fort Hood ESPC Project

    E-Print Network [OSTI]

    Haberl, J. S.; Liu, Z.; Baltazar-Cervantes, J. C.; Lynn, B.; Underwood, D.

    2004-01-01T23:59:59.000Z

    Fort Hood has selected an Energy Services Performance Contract (ESPC) contractor to help achieve its energy reduction goals as mandated by Executive Order. This ESPC is expected to be a $3.8 million, 20 year contract, which includes five primary...

  1. Preliminary assessment report for Fort Custer Training Center, Installation 26035, Augusta, Michigan. Installation Restoration Program

    SciTech Connect (OSTI)

    Flaim, S.; Krokosz, M.

    1993-08-01T23:59:59.000Z

    This report presents the results of the preliminary assessment (PA) conducted by Argonne National Laboratory at the Michigan Army National Guard property near Augusta, Michigan. Preliminary assessments of federal facilities are being conducted to compile the information necessary for completing preremedial activities and to provide a basis for establishing corrective actions in response to releases of hazardous substances. The principal objective of the PA is to characterize the site accurately and determine the need for further action by examining site activities, quantities of hazardous substances present, and potential pathways by which contamination could affect public health and the environment. This PA satisfies, for the Fort Custer Training Center, phase I of the Department of Defense Installation Restoration Program. The environmentally significant operations associated with the property are (1) storage of hazardous materials and hazardous waste, (2) storage and dispensing of fuel, (3) washing of vehicles and equipment, and (4) weapons training ranges that may have accumulated lead.

  2. Preliminary assessment report for Fort Jacob F. Wolters, Installation 48555, Mineral Wells, Texas. Installation Restoration Program

    SciTech Connect (OSTI)

    Dennis, C.B.

    1993-08-01T23:59:59.000Z

    This report presents the results of the preliminary assessment (PA) conducted by Argonne National Laboratory at the Texas Army National Guard (TXARNG) property near Mineral Wells, Texas. Preliminary assessments of federal facilities are being conducted to compile the information necessary for completing preremedial activities and to provide a basis for establishing corrective actions in response to releases of hazardous substances. The principal objective of the PA is to characterize the site accurately and determine the need for further action by examining site activities, quantities of hazardous substances present, and potential pathways by which contamination could affect public health and the environment. This PA satisfies, for the Fort Wolters property, the requirement of the Department of Defense Installation Restoration Program.

  3. Integrated Assessment Plan Template and Operational Demonstration for SPIDERS Phase 2: Fort Carson

    SciTech Connect (OSTI)

    Barr, Jonathan L.; Tuffner, Francis K.; Hadley, Mark D.; Kreyling, Sean J.; Schneider, Kevin P.

    2013-09-01T23:59:59.000Z

    This document contains the Integrated Assessment Plan (IAP) for the Phase 2 Operational Demonstration (OD) of the Smart Power Infrastructure Demonstration for Energy Reliability (SPIDERS) Joint Capability Technology Demonstration (JCTD) project. SPIDERS will be conducted over a three year period with Phase 2 being conducted at Fort Carson, Colorado. This document includes the Operational Demonstration Execution Plan (ODEP) and the Operational Assessment Execution Plan (OAEP), as approved by the Operational Manager (OM) and the Integrated Management Team (IMT). The ODEP describes the process by which the OD is conducted and the OAEP describes the process by which the data collected from the OD is processed. The execution of the OD, in accordance with the ODEP and the subsequent execution of the OAEP, will generate the necessary data for the Quick Look Report (QLR) and the Utility Assessment Report (UAR). These reports will assess the ability of the SPIDERS JCTD to meet the four critical requirements listed in the Implementation Directive (ID).

  4. Sandia National Laboratories: Locations

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItemResearch > TheNuclear PressLaboratorySoftware100LifeAnnouncementsLocations

  5. RENDERING FILTERS FOR CONTROLLING DETAIL AND

    E-Print Network [OSTI]

    RENDERING FILTERS FOR CONTROLLING DETAIL AND CREATING EFFECTS CHRISTOPHER ROBERT DECORO may be unified under the general theme of the rendering filter. Generally stated, such a filter is a passive, stateless operator that acts upon a decomposition of terms in the rendering equation

  6. Detailed Financial Procedures Page 1 of 3

    E-Print Network [OSTI]

    Levi, Ran

    Detailed Financial Procedures Page 1 of 3 Inventories and Disposals Background In accordance with Standing Financial Regulation, Heads of Departments are responsible for maintaining inventories for all disposals thereof. (Ref 8.03 & 8.06) Inventory Spreadsheet The following information should be recorded

  7. Contact details: School of Architecture, BCU

    E-Print Network [OSTI]

    Birmingham, University of

    With 90% of the UK population living in urban areas, improving urban sustainability has become a pressing Economic Fabric This work package investigated opportunities and barriers to achieving sustainable is to be sustainable in the widest sense. Contact details: Centre for Urban and Regional Studies, U0B Dr. Austin Barber

  8. Contact Details Journeying Beyond Breast Cancer

    E-Print Network [OSTI]

    Espinosa, Horacio D.

    Home About Contact Details Facebook Search Journeying Beyond Breast Cancer making sense of the cancer experience Feeds: Posts Comments Cancer-fighting fountain pen May 20, 2009 by JBBC A research team be used both as a research tool in the development of next-generation cancer treatments

  9. Detailed balance analysis of nanophotonic solar cells

    E-Print Network [OSTI]

    Fan, Shanhui

    Detailed balance analysis of nanophotonic solar cells Sunil Sandhu, Zongfu Yu, and Shanhui Fan-voltage characteristic modeling of nanophotonic solar cells. This approach takes into account the intrinsic material non-idealities, and is useful for determining the theoretical limit of solar cell efficiency for a given structure. Our approach

  10. Thirty Meter Telescope Detailed Science Case: 2015

    E-Print Network [OSTI]

    Skidmore, Warren; Fukugawa, Misato; Goswami, Aruna; Hao, Lei; Jewitt, David; Laughlin, Greg; Steidel, Charles; Hickson, Paul; Simard, Luc; Schöck, Matthias; Treu, Tommaso; Cohen, Judith; Anupama, G C; Dickinson, Mark; Harrison, Fiona; Kodama, Tadayuki; Lu, Jessica R; Macintosh, Bruce; Malkan, Matt; Mao, Shude; Narita, Norio; Sekiguchi, Tomohiko; Subramaniam, Annapurni; Tanaka, Masaomi; Tian, Feng; A'Hearn, Michael; Akiyama, Masayuki; Ali, Babar; Aoki, Wako; Bagchi, Manjari; Barth, Aaron; Bhalerao, Varun; Bradac, Marusa; Bullock, James; Burgasser, Adam J; Chapman, Scott; Chary, Ranga-Ram; Chiba, Masashi; Cooray, Asantha; Crossfield, Ian; Currie, Thayne; Das, Mousumi; Dewangan, G C; de Grijs, Richard; Do, Tuan; Dong, Subo; Evslin, Jarah; Fang, Taotao; Fang, Xuan; Fassnacht, Christopher; Fletcher, Leigh; Gaidos, Eric; Gal, Roy; Ghez, Andrea; Giavalisco, Mauro; Grady, Carol A; Greathouse, Thomas; Gogoi, Rupjyoti; Guhathakurta, Puragra; Ho, Luis; Hasan, Priya; Herczeg, Gregory J; Honda, Mitsuhiko; Imanishi, Masa; Inanmi, Hanae; Iye, Masanori; Kamath, U S; Kane, Stephen; Kashikawa, Nobunari; Kasliwal, Mansi; Kirby, Vishal KasliwalEvan; Konopacky, Quinn M; Lepine, Sebastien; Li, Di; Li, Jianyang; Liu, Junjun; Liu, Michael C; Lopez-Rodriguez, Enrigue; Lotz, Jennifer; Lubin, Philip; Macri, Lucas; Maeda, Keiichi; Marchis, Franck; Marois, Christian; Marscher, Alan; Martin, Crystal; Matsuo, Taro; Max, Claire; McConnachie, Alan; McGough, Stacy; Melis, Carl; Meyer, Leo; Mumma, Michael; Muto, Takayuki; Nagao, Tohru; Najita, Joan R; Navarro, Julio; Pierce, Michael; Prochaska, Jason X; Oguri, Masamune; Ojha, Devendra K; Okamoto, Yoshiko K; Orton, Glenn; Otarola, Angel; Ouchi, Masami; Packham, Chris; Padgett, Deborah L; Pandey, Shashi Bhushan; Pilachowsky, Catherine; Pontoppidan, Klaus M; Primack, Joel; Puthiyaveettil, Shalima; Ramirez-Ruiz, Enrico; Reddy, Naveen; Rich, Michael; Richter, Matthew J; Schombert, James; Sen, Anjan Ananda; Shi, Jianrong; Sheth, Kartik; Srianand, R; Tan, Jonathan C; Tanaka, Masayuki; Tanner, Angelle; Tominaga, Nozomu; Tytler, David; U, Vivian; Wang, Lingzhi; Wang, Xiaofeng; Wang, Yiping; Wilson, Gillian; Wright, Shelley; Wu, Chao; Wu, Xufeng; Xu, Renxin; Yamada, Toru; Yang, Bin; Zhao, Gongbo; Zhao, Hongsheng

    2015-01-01T23:59:59.000Z

    The TMT Detailed Science Case describes the transformational science that the Thirty Meter Telescope will enable. Planned to begin science operations in 2024, TMT will open up opportunities for revolutionary discoveries in essentially every field of astronomy, astrophysics and cosmology, seeing much fainter objects much more clearly than existing telescopes. Per this capability, TMT's science agenda fills all of space and time, from nearby comets and asteroids, to exoplanets, to the most distant galaxies, and all the way back to the very first sources of light in the Universe. More than 150 astronomers from within the TMT partnership and beyond offered input in compiling the new 2015 Detailed Science Case. The contributing astronomers represent the entire TMT partnership, including the California Institute of Technology (Caltech), the Indian Institute of Astrophysics (IIA), the National Astronomical Observatories of the Chinese Academy of Sciences (NAOC), the National Astronomical Observatory of Japan (NAOJ),...

  11. AVTA Federal Fleet PEV Readiness Data Logging and Characterization Study for the National Park Service: Fort Vancouver National Historic Site

    SciTech Connect (OSTI)

    Stephen Schey; Jim Francfort

    2014-03-01T23:59:59.000Z

    Battelle Energy Alliance, LLC, managing and operating contractor for the U.S. Department of Energy’s Idaho National Laboratory, is the lead laboratory for the U.S. Department of Energy’s Advanced Vehicle Testing. Battelle Energy Alliance, LLC contracted with Intertek Testing Services, North America (ITSNA) to collect data on federal fleet operations as part of the Advanced Vehicle Testing Activity’s Federal Fleet Vehicle Data Logging and Characterization study. The Advanced Vehicle Testing Activity study seeks to collect data to validate the use of advanced electric drive vehicle transportation. This report focuses on the Fort Vancouver National Historic Site (FVNHS) fleet to identify daily operational characteristics of select vehicles and report findings on vehicle and mission characterizations to support the successful introduction of electric vehicles (EVs) into the agencies’ fleet. Individual observations of the selected vehicles provided the basis for recommendations related to EV adoption and whether a battery electric vehicle (BEV) or plug-in hybrid electric vehicle (PHEV) (collectively plug-in electric vehicles) could fulfill the mission requirements. FVNHS identified three vehicles in its fleet for consideration. While the FVNHS vehicles conduct many different missions, only two (i.e., support and pool missions) were selected by agency management to be part of this fleet evaluation. The logged vehicles included a pickup truck and a minivan. This report will show that BEVs and PHEVs are capable of performing the required missions and providing an alternative vehicle for both mission categories, because each has sufficient range for individual trips and time available each day for charging to accommodate multiple trips per day. These charging events could occur at the vehicle’s home base, high-use work areas, or in intermediate areas along routes that the vehicles frequently travel. Replacement of vehicles in the current fleet would result in significant reductions in emission of greenhouse gases and petroleum use, while also reducing fuel costs. The Vancouver, Washington area and neighboring Portland, Oregon are leaders in adoption of PEVs in the United States1. PEV charging stations, or more appropriately identified as electric vehicle supply equipment, located on the FVNHS facility would be a benefit for both FVNHS fleets and general public use. Fleet drivers and park visitors operating privately owned plug-in electric vehicles benefit by using the charging infrastructure. ITSNA recommends location analysis of the FVNHS site to identify the optimal station placement for electric vehicle supply equipment. ITSNA recognizes the support of Idaho National Laboratory and ICF International for their efforts to initiate communication with the National Parks Service and FVNHS for participation in this study. ITSNA is pleased to provide this report and is encouraged by the high interest and support from the National Park Service and FVNHS personnel

  12. The Cricket indoor location system

    E-Print Network [OSTI]

    Priyantha, Nissanka Bodhi, 1968-

    2005-01-01T23:59:59.000Z

    Indoor environments present opportunities for a rich set of location-aware applications such as navigation tools for humans and robots, interactive virtual games, resource discovery, asset tracking, location-aware sensor ...

  13. CBECS 1992 - Building Characteristics, Detailed Tables

    Annual Energy Outlook 2013 [U.S. Energy Information Administration (EIA)]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742 33 111 1,613 122 40CoalLease(Billion2,128 2,469 2,321 2,590 1,550 1,460 1977-2013164 167Detailed

  14. First Detailed Look at RNA Dicer

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist.New MexicoFinancing Opportunities forFinishingFirst Detailed Look

  15. First Detailed Look at RNA Dicer

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField8,Dist.New MexicoFinancing Opportunities forFinishingFirst Detailed

  16. Annual Radiological Environmental Monitoring Program Report for the Fort St. Vrain Independent Spent Fuel Storage Installation (2003)

    SciTech Connect (OSTI)

    J. R. Newkirk; F. J. Borst, CHP

    2004-02-01T23:59:59.000Z

    This report presents the results of the 2003 Radiological Environmental Monitoring Program conducted in accordance with 10 CFR 72.44 for the Fort St. Vrain Independent Spent Fuel Storage Installation. A description of the facility and the monitoring program is provided. The results of monitoring the predominant radiation exposure pathway, direct radiation exposure, indicate the facility operation has not contributed to any increase in the estimated maximum potential dose commitment to the general public.

  17. Fort Worth Museum of Science and History: Reports on Federal Awards Program for the year ended September 30, 1994

    SciTech Connect (OSTI)

    NONE

    1994-12-31T23:59:59.000Z

    Six reports by independent accountants of the financial statements of the Fort Worth Museum of Science and History for the fiscal year ending September 30, 1994 are presented. The audits were performed on the financial statements on the (1) schedule of federal awards, (2) internal control structure, (3) compliance with laws, regulations, contracts, and grants, (4) the internal control structure used in administering federal awards, (5) compliance with general requirements, (6) compliance with specific requirements applicable to non-major program actions.

  18. History told from the depths of Lake Champlai: 1992-1993 Fort Ticonderoga-Mount Independence submerged cultural resource survey

    E-Print Network [OSTI]

    McLaughlin, Scott Arthur

    2000-01-01T23:59:59.000Z

    Campano Virginia West Funding The Fort Ticonderoga-Mount Independence Project could not have been completed without the cooperative efforts and funds from a number of federal and state government agencies. Federal funding was pmvided by the New... at its mouth (Johnson 1984). The topography and landforms visible today sunoundng the project area are products of ancient mountain-building process' and erosional forces of glaciers and rivers that gouged the valleys and scoured the surfaces...

  19. Study of well logs from Cove Fort-Sulphurdale KGRA, Millard and Beaver Counties, Utah

    SciTech Connect (OSTI)

    Glenn, W.E.; Ross, H.P.

    1982-07-01T23:59:59.000Z

    Union Oil Company drilled four geothermal test wells in the Cove Fort-Sulphurdale KGRA between 1975 and 1979. A fairly complete suite of well logs were recorded for the three deeper holes, and these data are presented as composite well log plots in this report. The composite well log plots have facilitated the interpretation of limestone, dolomite, sandstone, quartz-monzonite, serpentine, and volcanic lithologies and the identification of numerous fractures. This has been especially helpful because of the extensive lost circulaton zones and poor cuttings recovery. Intraformational flow was identified by a fluid migration-temperature tracer log at depth in CFSU 31-33. Well log crossplots were computed to assist in lithologic identification and the determination of physical properties for specific depth intervals in a given hole. The presence of hydrous minerals sometimes results in neutron porosity somewhat higher than the true nonfracture porosity, which is generally less than 4%. Permeability is clearly controlled by fractures. A maximum well temperature of 178.9/sup 0/C, low flow rates and low probable percent flash indicate these wells are subeconomic for electric generation at present. The well log study has substantially improved our understanding of the reservoir as presently drilled.

  20. Electrical Energy and Demand Savings from a Geothermal Heat Pump ESPC at Fort Polk, LA

    SciTech Connect (OSTI)

    Shonder, John A [ORNL; Hughes, Patrick [ORNL

    1997-06-01T23:59:59.000Z

    At Fort Polk, Louisiana, the space-conditioning systems of an entire city (4,003 military family housing units) have been converted to geothermal heat pumps (GHPs) under an energy savings performance contract. At the same time, other efficiency measures, such as compact fluorescent lights, low-flow hot water outlets, and attic insulation, were installed. Pre- and post-retrofit data were taken at 15-minute intervals on energy flows through the electrical distribution feeders that serve the family housing areas of the post. Fifteen-minute interval data were also taken on energy use from a sample of the residences. The analysis presented in this paper shows that for a typical meteorological year, the retrofits result in an electrical energy savings of approximately 25.6 million kWh, or 32.4% of the pre-retrofit electrical use in family housing. Peak electrical demand has also been reduced by about 6.8 MW, which is 40% of pre-retrofit peak demand. In addition, the retrofits save about 260,000 therms per year of natural gas. It should be noted that the energy savings presented in this document are the 'apparent' energy savings observed in the monitored data and are not to be mistaken for the 'contracted' energy savings used as the basis for payments. To determine the 'contracted' energy savings, the 'apparent' energy savings may require adjustments for such things as changes in indoor temperature performance criteri, addition of ceiling fans, and other factors.

  1. Fort Saint Vrain HTGR (Th/U carbide) Fuel Characteristics for Disposal Criticality Analysis

    SciTech Connect (OSTI)

    Taylor, Larry Lorin

    2001-01-01T23:59:59.000Z

    DOE-owned spent nuclear fuels encompass many fuel types. In an effort to facilitate criticality analysis for these various fuel types, they were categorized into eight characteristic fuel groups with emphasis on fuel matrix composition. Out of each fuel group, a representative fuel type was chosen for analysis as a bounding case within that fuel group. Generally, burnup data, fissile enrichments and total fuel mass govern the selection of the representative or candidate fuel within that group. For the HTGR group, the Fort Saint Vrain (FSV) reactor fuel has been chosen for the evaluation of viability for waste co-disposal. The FSV reactor was operated by Public Service of Colorado as a licensed power reactor. The FSV fuel employs a U/Th carbide matrix in individually pyrolytic carbon-coated particles. These individual particles are in turn coated with silicon carbide (SiC) and contained within fuel compacts, that are in turn embedded in graphite blocks that comprised the structural core of the reactor.

  2. New details on nuclear weapons program bared

    SciTech Connect (OSTI)

    Hileman, B.

    1994-07-11T23:59:59.000Z

    In a continuing effort to be more candid about Department of Energy nuclear weapons programs, Energy Secretary Hazel R. O'Leary recently declassified a substantial amount of information. On June 27, she revealed details about total US weapons-grade uranium production, testing of a bomb made of reactor-grade plutonium, radiation experiments conducted on humans since the 1920s, and underground and atmospheric nuclear weapons tests. O'Leary explains the new revelations by saying thousands of people in meetings across the country this year have told her that openness in government is very important. DOE is responding today in a manner that both satisfies the strong public interest and respects critical national security requirements.

  3. Improving Combustion Software to Solve Detailed Chemical Kinetics...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Combustion Software to Solve Detailed Chemical Kinetics for HECC Improving Combustion Software to Solve Detailed Chemical Kinetics for HECC 2012 DOE Hydrogen and Fuel Cells Program...

  4. Atomic detail brownian dynamics simulations of concentrated protein...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    detail brownian dynamics simulations of concentrated protein solutions with a mean field treatment of hydrodynamic Atomic detail brownian dynamics simulations of concentrated...

  5. Residential Windows and Window Coverings: A Detailed View of...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Residential Windows and Window Coverings: A Detailed View of the Installed Base and User Behavior Residential Windows and Window Coverings: A Detailed View of the Installed Base...

  6. Test Series 2. 3 detailed test plan

    SciTech Connect (OSTI)

    Not Available

    1983-12-01T23:59:59.000Z

    Test Series 2.3 is chronologically the second of the five sub-series of tests which comprise Test Series 2, the second major Test Series as part of the combustion research phase to be carried out at the Grimethorpe Experimental Pressurised Fluidised Bed Combustion Facility. Test Series 2.3 will consist of 700 data gathering hours which is expected to require some 1035 coal burning hours. The tests will be performed using US supplied coal and dolomite. This will be the first major series of tests on the Facility with other than the UK datum coal and dolomite. The document summarises the background to the facility and the experimental program. Described are modifications which have been made to the facility following Test Series 2.1 and a series of Screening Tests. Detailed test objectives are specified as are the test conditions for the experiments which comprise the test series. The test results will provide information on the effects of the bed temperature, excess air level, Ca/S ratio, number of coal feed lines, and combustion efficiency and sulphur retention. A significant aspect of the test series will be part load tests which will investigate the performance of the facility under conditions of turn down which simulate load following concepts specified for two combined cycle concepts, i.e., their CFCC combined cycle and a turbo charged combined cycle. The material test plan is also presented. The principal feature of the materials programme is the planned exposure of a set of static turbine blade specimens in a cascade test loop to the high temperature, high pressure flue gas. A schedule for the programme is presented as are contingency plans.

  7. Mobile Alternative Fueling Station Locator

    SciTech Connect (OSTI)

    Not Available

    2009-04-01T23:59:59.000Z

    The Department of Energy's Alternative Fueling Station Locator is available on-the-go via cell phones, BlackBerrys, or other personal handheld devices. The mobile locator allows users to find the five closest biodiesel, electricity, E85, hydrogen, natural gas, and propane fueling sites using Google technology.

  8. Precision zero-home locator

    DOE Patents [OSTI]

    Stone, W.J.

    1983-10-31T23:59:59.000Z

    A zero-home locator includes a fixed phototransistor switch and a moveable actuator including two symmetrical, opposed wedges, each wedge defining a point at which switching occurs. The zero-home location is the average of the positions of the points defined by the wedges.

  9. Baseline Report for the Fort Hood Army Base: Sept. 1, 2002 - Aug. 31, 2003

    E-Print Network [OSTI]

    Haberl, J. S.; Baltazar-Cervantes, J. C.; Liu, Z.; Claridge, D. E.; Turner, W. D.

    2003-01-01T23:59:59.000Z

    A&M University ABSTRACT This report presents electricity, natural gas and cooling baselines for the thermal plant, buildings located in the 87000 block, III Corp building and other buildings that were determined to be part of the ESPC project...

  10. A preliminary analysis of league bowlers, casual bowlers, and non-bowlers in the Dallas-Fort Worth metropolian area

    E-Print Network [OSTI]

    Lawrence, Larry Ray

    1977-01-01T23:59:59.000Z

    -Fort Worth metropolitan area. The differ nce in the age of the classif. ications of bowlers would seem to indicate that, new sources of revenue lie with the young casual bowler. 1f proprietors can convert the young casual bowlers to young league bowlers... the apparatus of a game very similar to modern day bowling. Sir Flinders of Petrie, emeritus professor o f Egyptology, the Univer- sity of London, found nine pieces of stone, used as pins and a stone ball (The National Bowling Council, 1974) The parishioners...

  11. Aerial gamma ray and magnetic survey: Mississippi and Florida airborne survey, Fort Smith quadrangle, Oklahoma, and Arkansas. Final report

    SciTech Connect (OSTI)

    Not Available

    1980-09-01T23:59:59.000Z

    The Fort Smith quadrangle in western Arkansas and eastern Oklahoma overlies thick Paleozoic sediments of the Arkoma Basin. These Paleozoics dominate surface exposure except where covered by Quaternary Alluvial materials. Examination of available literature shows no known uranium deposits (or occurrences) within the quadrangle. Seventy-five groups of uranium samples were defined as anomalies and are discussed briefly. None were considered significant, and most appeared to be of cultural origin. Magnetic data show character that suggest structural and/or lithologic complexity, but imply relatively deep-seated sources.

  12. An Information Theoretic Location Verification System for Wireless Networks

    E-Print Network [OSTI]

    Yan, Shihao; Nevat, Ido; Peters, Gareth W

    2012-01-01T23:59:59.000Z

    As location-based applications become ubiquitous in emerging wireless networks, Location Verification Systems (LVS) are of growing importance. In this paper we propose, for the first time, a rigorous information-theoretic framework for an LVS. The theoretical framework we develop illustrates how the threshold used in the detection of a spoofed location can be optimized in terms of the mutual information between the input and output data of the LVS. In order to verify the legitimacy of our analytical framework we have carried out detailed numerical simulations. Our simulations mimic the practical scenario where a system deployed using our framework must make a binary Yes/No "malicious decision" to each snapshot of the signal strength values obtained by base stations. The comparison between simulation and analysis shows excellent agreement. Our optimized LVS framework provides a defence against location spoofing attacks in emerging wireless networks such as those envisioned for Intelligent Transport Systems, wh...

  13. Fort Peck-Havre transmission line project, Hill, Blaine, Phillips, Valley and McCone Counties, Montana

    SciTech Connect (OSTI)

    Not Available

    1982-09-01T23:59:59.000Z

    Construction and operation of a 180-mile, 230-kilovlt (kV) transmission line between Fort Peck and Havre, Montana is proposed to provide a replacement for the 161-kV line that currently runs between the two cities. The new line would be carried on woodpole, H-frame structures. The existing 161-kV line would be removed, and the Richardson Coulee Substation would be relocated. Intermediate facilities to be improved would include the Fort Peck Switchyard and the Richardson Coulee, Malta, Harlem, and Havre substations.Construction of the line would commence in August 1983, and operation would commence in January 1986. The expected life of the transmission system would be 100 years. Estimated cost of the project, in 1983 dollars, is $36.1 million. The project would upgrade an essential element of the Western Area Power Administration's electric power system and the Montana Power Company's interconnected transmission network. Continued electric service reliability would be improved, and safety conditions affecting personnel who maintain the line would be enhanced. Additional transmission capacity would be provided to accommodate future load growth, precluding the need for multiple transmission lines. The line would eleminate seven acres of productive land and create physical conflicts with present and future agricultural activities. The line would traverse areas characterized by concentrations of archaeological resources and cultural resources of importance to native Americans. Transmission structures could mar scenery in areas with historically significant architecture and would interfere with waterfowl.

  14. Alternate States of Proteins Revealed by Detailed Energy Landscape Mapping

    E-Print Network [OSTI]

    Baker, David

    Alternate States of Proteins Revealed by Detailed Energy Landscape Mapping Michael D. Tyka1 Keywords: Rosetta; alternative conformations; protein mobility; structure prediction; validation What through analysis of detailed protein energy landscapes generated by large-scale, native- enhanced sampling

  15. American Recovery and Reinvestment Act (ARRA) Federal Energy Management Program Technical Assistance Project 282 Renewable Energy Opportunities at Fort Gordon, Georgia

    SciTech Connect (OSTI)

    Boyd, Brian K.; Gorrissen, Willy J.; Hand, James R.; Horner, Jacob A.; Orrell, Alice C.; Russo, Bryan J.; Weimar, Mark R.; Williamson, Jennifer L.; Nesse, Ronald J.

    2010-09-30T23:59:59.000Z

    This document provides an overview of renewable resource potential at Fort Gordon, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations. This effort focuses on grid-connected generation of electricity from renewable energy sources and also on ground source heat pumps for heating and cooling buildings. The effort was funded by the American Recovery and Reinvestment Act (ARRA) as follow-on to the 2005 Department of Defense (DoD) Renewables Assessment. The site visit to Fort Gordon took place on March 9, 2010.

  16. Griffiss AFB integrated resource assessment. Volume 2, Electric baseline detail

    SciTech Connect (OSTI)

    Dixon, D.R.; Armstrong, P.R.; Keller, J.M.

    1993-02-01T23:59:59.000Z

    The US Air Force Air Combat Command has tasked the Pacific Northwest Laboratory (PNL) as the lead laboratory supporting the US Department of Energy (DOE) Federal Energy Management Program`s (FEMP) mission to identify, evaluate, and assist in acquiring all cost-effective energy projects at Griffiss Air Force Base (AFB). This is a model program PNL is designing for federal customers served by the Niagara Mohawk Power Company (Niagara Mohawk). It will (1) identify and evaluate all electric cost-effective energy projects; (2) develop a schedule at each installation for project acquisition considering project type, size, timing, and capital requirements, as well as energy and dollar savings; and (3) secure 100% of the financing required to implement electric energy efficiency projects from Niagara Mohawk and have Niagara Mohawk procure the necessary contractors to perform detailed audits and install the technologies. This report documents the assessment of baseline energy use at one of Niagara Mohawk`s primary federal facilities, Griffiss AFB, an Air Combat Command facility located near Rome, New York. It is a companion report to Volume 1, the Executive Summary, and Volume 3, the Electric Resource Assessment. The analysis examines the characteristics of electric, gas, oil, propane, coal, and purchased thermal capacity use for fiscal year (FY) 1990. The results include energy-use intensities for the facilities at Griffiss AFB by building type and electric energy end use. A complete electric energy consumption reconciliation is presented that accounts for the distribution of all major electric energy uses and losses among buildings, utilities, and central systems.

  17. Synchronized sampling improves fault location

    SciTech Connect (OSTI)

    Kezunovic, M. [Texas A and M Univ., College Station, TX (United States)] [Texas A and M Univ., College Station, TX (United States); Perunicic, B. [Lamar Univ., Beaumont, TX (United States)] [Lamar Univ., Beaumont, TX (United States)

    1995-04-01T23:59:59.000Z

    Transmission line faults must be located accurately to allow maintenance crews to arrive at the scene and repair the faulted section as soon as possible. Rugged terrain and geographical layout cause some sections of power transmission lines to be difficult to reach. In the past, a variety of fault location algorithms were introduced as either an add-on feature in protective relays or stand-alone implementation in fault locators. In both cases, the measurements of current and voltages were taken at one terminal of a transmission line only. Under such conditions, it may become difficult to determine the fault location accurately, since data from other transmission line ends are required for more precise computations. In the absence of data from the other end, existing algorithms have accuracy problems under several circumstances, such as varying switching and loading conditions, fault infeed from the other end, and random value of fault resistance. Most of the one-end algorithms were based on estimation of voltage and current phasors. The need to estimate phasors introduces additional difficulty in high-speed tripping situations where the algorithms may not be fast enough in determining fault location accurately before the current signals disappear due to the relay operation and breaker opening. This article introduces a unique concept of high-speed fault location that can be implemented either as a simple add-on to the digital fault recorders (DFRs) or as a stand-alone new relaying function. This advanced concept is based on the use of voltage and current samples that are synchronously taken at both ends of a transmission line. This sampling technique can be made readily available in some new DFR designs incorporating receivers for accurate sampling clock synchronization using the satellite Global Positioning System (GPS).

  18. Location logistics of industrial facilities

    E-Print Network [OSTI]

    Hammack, William Eugene

    1981-01-01T23:59:59.000Z

    of company intent1ons is not made at the correct time and in the correct manner. 6. Recommend Best Areas for Further Invest1 ations. Once the on-site evaluations have been completed, the 11st of possibilities is reduced still further and only the best... location and site selection. This data was gathered through library research, atten- dance of various industr1al development conferences, sol1citation of mater1als from individuals currently involved with industrial facil1ties location, and various...

  19. Building Address Locations -Assumes entire

    E-Print Network [OSTI]

    Guenther, Frank

    Building Address Locations - Assumes entire building unless noted Designation Submit through* 560, 4 BU Crosstown Center 801 Massachusetts Ave Floor 1, 2 BMC BCD Building 800 Harrison Avenue BCD BMC Biosquare III 670 Albany Floors 2, 3, 6, 7 BMC Biosquare III 670 Albany Floors 1, 4, 5, 8 BU Building

  20. Boston, Massachusetts Location: Boston, MA

    E-Print Network [OSTI]

    Prevedouros, Panos D.

    -recovery ventilation and water-source heat pumps Each unit has fresh air ducted independently. Each residence is warmed by a heat pump that taps the Trigen Energy Corporation steam lines that run underneath the street. #12;WallsBoston, Massachusetts #12;Location: Boston, MA Building type(s): Multi-unit residential, Retail 350

  1. Phyllosilicate orientation demonstrates early timing of compactional stabilization in calcite-cemented concretions in the Barnett Shale (Late Mississippian), Fort Worth

    E-Print Network [OSTI]

    -cemented concretions in the Barnett Shale (Late Mississippian), Fort Worth Basin, Texas (U.S.A) Ruarri J. Day-Stirrat a in revised form 8 April 2008 Accepted 16 April 2008 Keywords: Barnett Shale Goniometry Concretions Fabric Calcite-cemented zones in the prolific gas-producing Barnett Shale (Ft. Worth Basin, Texas) preserve very

  2. 3-DOF potential air flow manipulation by inverse modeling control Anne Delettre, Guillaume J. Laurent, Nadine Le Fort-Piat and Christophe Varnier

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    3-DOF potential air flow manipulation by inverse modeling control Anne Delettre, Guillaume J. Laurent, Nadine Le Fort-Piat and Christophe Varnier Abstract-- Potential air flows can be used to perform non- prehensile contactless manipulations of objects gliding on air- hockey table. In this paper, we

  3. Crosswell Seismic Amplitude-Versus-Offset for Detailed Imaging of Facies and Fluid Distribution within Carbonate Oil Reservoirs

    E-Print Network [OSTI]

    Crosswell Seismic Amplitude-Versus-Offset for Detailed Imaging of Facies and Fluid Distribution, and demonstrate a method of using crosswell seismic profiling for identification of trapped oil, bypassed reservoir compartments, and location of fluid fronts in carbonate reefs. The method of crosswell seismic

  4. In Situ Redox Manipulation Proof-of-Principle Test at the Fort Lewis Logistics Center: Final Report

    SciTech Connect (OSTI)

    VR Vermeul; MD Williams; JC Evans; JE Szecsody; BN Bjornstad; TL Liikala

    2000-10-25T23:59:59.000Z

    Pacific Northwest National Laboratory (PNNL) conducted a proof-of-principle test at the Fort Lewis Logistics Center to determine the feasibility of using the In Situ Redox Manipulation (ISRM) technology for remediating groundwater contaminated with dissolved trichloroethylene (TCE). ISRM creates a permeable treatment zone in the subsurface to remediate redox-sensitive contaminants in groundwater. The permeable treatment zone is formed by injecting a chemical reducing agent (sodium dithionite with pH buffers) into the aquifer through a well to reduce the naturally occurring ferric iron in the sediments to ferrous iron. Once the reducing agent is injected and given sufficient time to react with aquifer sediments, residual chemicals and reaction products are withdrawn from the aquifer through the same well used for the injection. Redox-sensitive contaminants such as TCE, moving through the treatment zone under natural groundwater flow conditions, are destroyed. TCE is degraded via reductive dechlorination within the ISRM treatment zone to benign degradation products (i.e., acetylene, ethylene). Prior to the proof-of-principle field test, the ISRM technology was successfully demonstrated in laboratory experiments for the reductive dechlorination of dissolved TCE using sediments from the Fort Lewis site. The Logistics Center was placed on the National Priorities List in December 1989 because of TCE contamination in groundwater beneath the site. A Federal Facilities Agreement between the Army, the U.S. Environmental Protection Agency, and the Washington State Department of Ecology became effective in January 1990, and a Record of Decision (ROD) was signed in September 1990. The major components of the ROD included installation of two pump-and-treat systems for the upper aquifer and further investigation of the lower aquifer and other potential sources of contamination. The pump-and-treat systems became operational in August 1995. Fort Lewis asked PNNL to provide technical support in accelerating Installation Restoration Program site remediation and significantly reducing site life-cycle costs at the Logistics Center. In support of this program, ISRM was selected as an innovative technology for bench and field-scale demonstration. Emplacement of the ISRM treatment zone was accomplished through a series of four separate dithionite injection tests conducted between November 10, 1998 and March 29,2000. An extensive program of chemical monitoring was also performed before, during, and after each injection to evaluate the performance of ISRM. Prior to emplacement of the ISRM treatment zone, the site was extensively characterized with respect to geologic, hydrologic, and geochemical properties. Sediment core samples collected for the characterization studies were analyzed in bench-scale column tests at PNNL to determine reducible iron content. These site-specific hydrogeologic and geochemical data were used to develop the emplacement design of the pilot-scale (i.e., single injection well) ISRM treatment zone. Performance data obtained from the proof-of-principle test indicate that field-scale reductive dechlorination of TCE using the ISRM technology is feasible. A treatment zone was created in the subsurface that reduced TCE concentrations as much as 92% on the downgradient side of the reduced zone, from a background concentration of approximately 140 ppb to approximately 11 ppb. The appearance of the principal degradation product, acetylene, also confirmed that TCE destruction was occurring. Analysis of sediment samples collected from post-test boreholes showed a high degree of iron reduction, which helped to confirm the effectiveness of the treatment zone emplacement. Another important goal of the testing program was to provide assurances that chemical treatment of the subsurface did not result in undesirable secondary effects, including formation of toxic TCE degradation products, mobilization of trace elements, and degradation of hydraulic performance. Results obtained from the Fort Lewis ISRM proof-of-principle test, which are c

  5. EIS-0473: W.A. Parish Post-Combustion CO2 Capture and Sequestration Project (PCCS), Fort Bend County, TX

    Broader source: Energy.gov [DOE]

    This EIS evaluates the environmental impacts of a proposal to provide financial assistance for a project proposed by NRG Energy, Inc (NRG). DOE selected NRG’s proposed W.A. Parish Post-Combustion CO2 Capture and Sequestration Project for a financial assistance award through a competitive process under the Clean Coal Power Initiative Program. NRG would design, construct and operate a commercial-scale carbon dioxide (CO2) capture facility at its existing W.A. Parish Generating Station in Fort Bend County, Texas; deliver the CO2 via a new pipeline to the existing West Ranch oil field in Jackson County, Texas, for use in enhanced oil recovery operations; and demonstrate monitoring techniques to verify the permanence of geologic CO2 storage.

  6. Details, details...The impact of market rules on emerging ``green'' energy markets

    SciTech Connect (OSTI)

    Wiser, R.H.; Pickle, S.J.; Eto, J.H.

    1998-07-01T23:59:59.000Z

    Green power marketing is creating a customer-driven market for renewable energy resources, including solar, wind, geothermal, biomass, and hydropower. Yet there are a number of market barriers to the creation of a workable green power market, and the ultimate success of retail markets for green power products will depend critically on the detailed market rules established at the onset of restructuring and on a number of market facilitation efforts. By surveying green power marketers and reviewing regulatory filings, this paper identifies and analyzes the types of restructuring market rules and market facilitation efforts that impact the competitive market for electricity services broadly, and the retail market for green power specifically. Taking a marketer perspective as the point of reference, they emphasize those rules and efforts that most effectively target key market barriers and that might be most successful in expanding the market for retail green power products. This information should help those interested in encouraging the development of the green power market during the early years of electricity restructuring.

  7. New Argonne initiative to examine the details of the combustion...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Argonne initiative to examine the details of the combustion process By Jared Sagoff * July 15, 2014 Tweet EmailPrint ARGONNE, Ill. - Every science experiment and every mathematical...

  8. Pumped Storage Hydropower (Detailed Analysis to Demonstrate Value...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Pumped Storage Hydropower (Detailed Analysis to Demonstrate Value)-Modeling and Analysis of Value of Advanced Pumped Storage Hydropower in the U.S. Pumped Storage Hydropower...

  9. Detailed Assessment of Particulate Characteristics from Low-Temperatur...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Assessment of Particulate Characteristics from Low-Temperature Combustion Engines Detailed Assessment of Particulate Characteristics from Low-Temperature Combustion Engines 2012...

  10. Premiere issue of "Quest" magazine details PPPL's strides toward...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Premiere issue of "Quest" magazine details PPPL's strides toward fusion energy and advances in plasma science September 5, 2013 Tweet Widget Google Plus One Share on Facebook Quest...

  11. Two Studies Reveal Details of Lithium-Battery Function

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Two Studies Reveal Details of Lithium-Battery Function Print Our way of life is deeply intertwined with battery technologies that have enabled a mobile revolution powering cell...

  12. azobenzene detailed mechanism: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Post Graduate Activities Detail & History Materials Science Websites Summary: Raytheon Systems Engineer Tucson AZ MENG Rockwell Collins Mechanical Engineer Sterling VA MENG...

  13. A Stochastic Reactor Based Virtual Engine Model Employing Detailed...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    A Stochastic Reactor Based Virtual Engine Model Employing Detailed Chemistry for Kinetic Studies of In-Cylinder Combustion and Exhaust Aftertreatment A Stochastic Reactor Based...

  14. Letter from Commonwealth of Virginia to ENSR International Detailing...

    Broader source: Energy.gov (indexed) [DOE]

    ENSR International Detailing Responses to Comments made Concerning the Modified Protocol for Downwash Modeling-Mirant Potomac River, LLC. The comments are addressed for the most...

  15. Joint microseismic event location with uncertain velocity

    E-Print Network [OSTI]

    Poliannikov, Oleg V.

    2013-01-01T23:59:59.000Z

    We study the problem of the joint location of seismic events using an array of receivers. We show that locating multiple seismic events simultaneously is advantageous compared to the more traditional approaches of locating ...

  16. Geographic Information System At Cove Fort Area - Vapor (Nash, Et Al.,

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directedAnnualPropertyd8c-a9ae-f8521cbb8489InformationFrenchtown,Jump to:Locations2002) | Open Energy

  17. Energy Department Launches Alternative Fueling Station Locator...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Energy Department Launches Alternative Fueling Station Locator App Energy Department Launches Alternative Fueling Station Locator App November 7, 2013 - 11:16am Addthis As part of...

  18. Asymptotic analysis of an optimal location problem

    E-Print Network [OSTI]

    2003-05-13T23:59:59.000Z

    Asymptotic analysis of an optimal location problem. One considers the problem of optimal location of masses(say production centers) in order to approximate a ...

  19. BUILDING SURROGATE MODELS BASED ON DETAILED AND APPROXIMATE SIMULATIONS

    E-Print Network [OSTI]

    Seepersad, Carolyn Conner

    - Page 1 - BUILDING SURROGATE MODELS BASED ON DETAILED AND APPROXIMATE SIMULATIONS Zhiguang Qian is taken to integrate data from approximate and detailed simulations to build a surrogate model approximate simulations form the bulk of the data, and they are used to build a model based on a Gaussian

  20. A DETAILLED WEATHER DATA GENERATOR FOR BUILDINGS SIMULATION

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    A DETAILLED WEATHER DATA GENERATOR FOR BUILDINGS SIMULATION L. ADELARD*, H. BOYER, F. GARDE, J@iremia.univ-reunion.fr Abstract Thermal buildings simulation softwares need meteorological files in thermal comfort, energetic@iremia.univ-reunion.fr #12;1 A DETAILLED WEATHER DATA GENERATOR FOR BUILDINGS SIMULATION L. Adelard*, H. Boyer, F. Garde, J

  1. Structure of Partially Premixed Flames Using Detailed Chemistry Simulations 

    E-Print Network [OSTI]

    Kluzek, Celine D.

    2010-10-12T23:59:59.000Z

    , and the attendant effects on a number of species. Using the detailed analysis of different reaction rates, the adiabatic and radiative nitric oxide concentrations are compared. The cross-transport effects, i.e. Soret and Dufour, were studied in detail. The Soret...

  2. A detailed systematic review of the recent literature on environmental

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    EA 4272 A detailed systematic review of the recent literature on environmental Kuznets curve detailed systematic review of the recent literature on environmental Kuznets curve dealing with CO2 Marie the early 90', many articles have been published on Environmental Kuznets Curve (EKC), especially empirical

  3. Detailed chemical kinetic oxidation mechanism for a biodiesel Olivier Herbineta

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Detailed chemical kinetic oxidation mechanism for a biodiesel surrogate Olivier Herbineta , William of methyl decanoate, a surrogate for biodiesel fuels. This model has been built by following the rules and biodiesel fuels to predict overall reactivity, but some kinetic details, including early CO2 production from

  4. Borehole locations on seven interior salt domes

    SciTech Connect (OSTI)

    Simcox, A.C.; Wampler, S.L.

    1982-08-01T23:59:59.000Z

    This report is designed as an inventory of all wells known to have been drilled within a five-mile radius of each of seven salt domes within the Interior Salt Basin in east Texas, northern Louisiana and Mississippi. There are 72 boreholes that entered salt above an elevation of -3000 feet mean sea level. For these, details of location, drilling dates, depth of casing and cement, elevation of top of caprock and salt, etc., are given on tables in the appendix. Of the seven domes, Oakwood has the largest number of boreholes, thirty-eight (including two sidetracked wells) that enter the salt stock above -3000 feet mean sea level; another dome in northeast Texas, Keechi, has eight; in northern Louisiana, Rayburn's has four and Vacherie has five; in southern Mississippi, Cypress Creek has seven, Lampton has one, and Richton has nine. In addition, all wells known outside the supra-domal area, but within a five-mile radius of the center of the 7 domes are separately catalogued.

  5. SAPLE: Sandia Advanced Personnel Locator Engine.

    SciTech Connect (OSTI)

    Procopio, Michael J.

    2010-04-01T23:59:59.000Z

    We present the Sandia Advanced Personnel Locator Engine (SAPLE) web application, a directory search application for use by Sandia National Laboratories personnel. SAPLE's purpose is to return Sandia personnel 'results' as a function of user search queries, with its mission to make it easier and faster to find people at Sandia. To accomplish this, SAPLE breaks from more traditional directory application approaches by aiming to return the correct set of results while placing minimal constraints on the user's query. Two key features form the core of SAPLE: advanced search query interpretation and inexact string matching. SAPLE's query interpretation permits the user to perform compound queries when typing into a single search field; where able, SAPLE infers the type of field that the user intends to search on based on the value of the search term. SAPLE's inexact string matching feature yields a high-quality ranking of personnel search results even when there are no exact matches to the user's query. This paper explores these two key features, describing in detail the architecture and operation of SAPLE. Finally, an extensive analysis on logged search query data taken from an 11-week sample period is presented.

  6. Field Demonstration of a High-Efficiency Packaged Rooftop Air Conditioning Unit at Fort Gordon, Augusta, GA

    SciTech Connect (OSTI)

    Armstrong, Peter R.; Sullivan, Gregory P.; Parker, Graham B.

    2006-03-31T23:59:59.000Z

    As part of a larger program targeting the market transformation of packaged rooftop air conditioning, five high-efficiency rooftop air conditioning products were selected in 2002 by the U.S. Department of Energy (DOE) under the Unitary Air Conditioner (UAC) Technology Procurement (http://www.pnl.gov/uac). In February 2003, Fort Gordon in Augusta, Georgia was chosen as the demonstration site. With the goal of validating the field performance and operation of one of the awarded products, a 10-ton high-efficiency packaged rooftop unit (RTU) manufactured by Global Energy Group (GEG) was installed at Fort Gordon in October 2003. Following equipment installation, power metering, air- and refrigerant-side instrumentation was installed on the GEG RTU and a 4-year old typical-efficiency 20-ton RTU manufactured by AAON . The GEG and AAON units were instrumented identically and operated May through July, 2005, to observe performance under a range of conditions. Based on the data collected as part of this demonstration, the GEG equipment performed at least 8% better in stage-1 (single compressor running) cooling and at least 16% better in stage-2 (both compressors running) than the baseline AAON equipment. Performance comparisons are based on what we call application EER normalized to equivalent specific fan power. The full-load, specific-fan-power-normalized application EERs at ARI design conditions were 10.48 Btu/Wh for the GEG and 9.00 Btu/Wh for the baseline machine. With a cost premium of nearly 50%, and slightly higher maintenance costs, the life-cycle cost analysis shows that the GEG technology pays for itself--a positive net-present value (NPV)--only in climates and buildings with long cooling seasons. Manufacture of this equipment on a larger scale can be expected to reduce costs to the point where it is more broadly cost-effective. The assumed 10-ton baseline and new-technology unit costs are $3824.00 and $5525.00 respectively. If the new technology cost is assumed to drop as sales increase to $4674.50 for a 10-ton unit (i.e. the original cost difference is halved), the life-cycle costs improve. A grid of first cost, annual maintenance cost and electricity price is enumerated and the results presented in the report show the sensitivity of life cycle cost to these three financial parameters in each of eight different climates.

  7. Fuel Cell Technologies Office: Past Events EventsDetail

    Broader source: Energy.gov (indexed) [DOE]

    Events Printable Version Share this resource Send a link to Fuel Cell Technologies Office: Past Events EventsDetail to someone by E-mail Share Fuel Cell Technologies Office: Past...

  8. Detailed Description of Key NIF Milestones for NNSA Description

    E-Print Network [OSTI]

    1 Detailed Description of Key NIF Milestones for NNSA Short Description NIC EP Rev 4.0 Approved = Milestone Reporting Tool, which NNSA uses to support quarterly status reporting of NIC Level 1-2 milestones

  9. The detailed proposal for ECN and IP: K. K. Ramakrishnan,

    E-Print Network [OSTI]

    Floyd, Sally

    #12;Details of ECN and IP: The IPv4 TOS byte is currently defined as follows. This byte is under +-----+-----+-----+-----+-----+-----+-----+-----+ | PRECEDENCE | TOS | | +-----+-----+-----+-----+-----+-----+-----+-----+ 2 #12;Our proposal is as follows: 0 1

  10. The effect of network detail on traffic assignment

    E-Print Network [OSTI]

    Long, Gary Don

    1968-01-01T23:59:59.000Z

    exceed the actual separation on the ground. Thus, with the coded networks common1y used, severs!. city blocks are appropri. ately aggregated to form a single zone. The zone centroid is connected to the network in a manner consistent with the physical... these facil- ities and underloading the arterials and collectors. CHAPTER II I NETWORK AS SIGNHENT Detailed Network The initial assignr, . ent of the detailed network resulted in con- siderable disagreement between assigned volumes and ground counts...

  11. Natural gas cost for evaluating energy resource opportunities at Fort Stewart

    SciTech Connect (OSTI)

    Stucky, D.J.; Shankle, S.A.

    1993-01-01T23:59:59.000Z

    Ft. Stewart, a United States Army Forces Command (FORSCOM) installation located near Hinesville, Georgia, is currently undergoing an evaluation of its energy usage, which is being performed by Pacific Northwest Laboratory. In order to examine the energy resource opportunities (EROs) at Ft. Stewart, marginal fuel costs must be calculated. The marginal, or avoided, cost of gas service is used in conjunction with the estimated energy savings of an ERO to calculate the dollar value of those savings. In the case of natural gas, the costing becomes more complicated due to the installation of a propane-air mixing station. The propane-air station is being built under a shared energy savings (SES) contract. The building of a propane-air station allows Ft. Stewart to purchase natural gas from their local utility at an interruptible rate, which is lower than the rate for contracting natural gas on a firm basis. The propane-air station will also provide Ft. Stewart with fuel in the event that the natural gas supply is curtailed. While the propane-air station does not affect the actual cost of natural gas, it does affect the cost of services provided by gas. Because the propane-air station and the SES contract affect the cost of gas service, they must be included in the analysis. Our analysis indicates a marginal cost of gas service of 30.0 cents per therm, assuming a total propane usage by the mixing station of 42,278 gallons (38,600 therms) annually. Because the amount of propane that may be required in the event of a curtailment is small relative to the total service requirement, variations in the actual amount should not significantly affect the cost per therm.

  12. Fort Devens: Cold Climate Market-Rate Townhomes Targeting HERS Index of 40, Harvard, Massachusetts (Fact Sheet)

    SciTech Connect (OSTI)

    Not Available

    2013-11-01T23:59:59.000Z

    Achieving aggressive energy efficiency targets requires tight coordination and clear communication among owners, designers, builders, and subcontractors. For this townhome project, MassDevelopment, the quasi-governmental agency owner, selected Metric Development of Boston, teaming with the U.S. Department of Energy (DOE) Consortium for Advanced Residential Buildings (CARB) and Cambridge Seven Architects, to build very high performing market-rate homes. Fort Devens is part of a decommissioned army base in working-class Harvard, Massachusetts, approximately one hour northwest of Boston. The team proposed 12 net zero energy-ready townhomes, meaning that the application of renewable energy systems would result in annual net zero energy use in the homes. The homes were also designed to achieve a Home Energy Rating System (HERS) Index Score of 41 before adding renewables. For this project, CARB drew on its experience working with Rural Development Inc. on a series of affordable townhomes in northern Massachusetts. The team carefully planned the site to maximize solar access, daylighting, and efficient building forms. The basic strategy was to design a very efficient thermal enclosure while minimizing incremental cost increases compared with standard construction. Using BEopt modeling software, the team established the requirements of the enclosure and investigated multiple assembly options. They settled on double-wall construction with dense-pack cellulose fill. High performance vinyl windows (U-0.24, solar heat gain coefficient [SHGC]-0.22), a vented R-59 attic, and exceptional air sealing completed the package.

  13. Superfund Record of Decision (EPA Region 10): Fort Wainwright, Operable Unit 2, Fairbanks North Star Borough, AK, March 31, 1997

    SciTech Connect (OSTI)

    NONE

    1997-11-01T23:59:59.000Z

    This Record of Decision (ROD) presents the selected remedial actions for Operable Unit 2 (OU-2) at Fort Wainwright in Fairbanks, Alaska. OU-2 originally consisted in eight source areas: the defense Reutilization and Marketing Office (DRMO) Yard, the Building 1168 Leach Well, the North Post Site, the 801 Drum Burial Site, the Engineers Park Drum Site, the Drum Site South of the Landfill, Building 3477, and the Tar Sites. The major components of the remedies at source areas are: in situ soil vapor extraction and air sparging of the groundwater to reduce volatile organic compounds to a level that meets state and federal MCLs; institutional controls that would include restrictions on groundwater well installations, site access restrictions, and maintenance of fencing at the DRMO Yard until state and federal MCLs are met; additional institutional controls, including a limitation on refilling the DRMO Yard fire suppression water tank from the existing potable water supply well, until state and federal MCLs are met (except in emergency situations); and natural attenuation to attain Alaska Water Quality Standards after reaching state and federal MCLs.

  14. Study on detailed geological modelling for fluvial sandstone reservoir in Daqing oil field

    SciTech Connect (OSTI)

    Zhao Hanqing; Fu Zhiguo; Lu Xiaoguang [Institute of Petroleum Exploration and Development, Daqing (China)

    1997-08-01T23:59:59.000Z

    Guided by the sedimentation theory and knowledge of modern and ancient fluvial deposition and utilizing the abundant information of sedimentary series, microfacies type and petrophysical parameters from well logging curves of close spaced thousands of wells located in a large area. A new method for establishing detailed sedimentation and permeability distribution models for fluvial reservoirs have been developed successfully. This study aimed at the geometry and internal architecture of sandbodies, in accordance to their hierarchical levels of heterogeneity and building up sedimentation and permeability distribution models of fluvial reservoirs, describing the reservoir heterogeneity on the light of the river sedimentary rules. The results and methods obtained in outcrop and modem sedimentation studies have successfully supported the study. Taking advantage of this method, the major producing layers (PI{sub 1-2}), which have been considered as heterogeneous and thick fluvial reservoirs extending widely in lateral are researched in detail. These layers are subdivided into single sedimentary units vertically and the microfacies are identified horizontally. Furthermore, a complex system is recognized according to their hierarchical levels from large to small, meander belt, single channel sandbody, meander scroll, point bar, and lateral accretion bodies of point bar. The achieved results improved the description of areal distribution of point bar sandbodies, provide an accurate and detailed framework model for establishing high resolution predicting model. By using geostatistic technique, it also plays an important role in searching for enriched zone of residual oil distribution.

  15. Analysis of the AirTouch automatic vehicle location system's ability to locate moving vehicles 

    E-Print Network [OSTI]

    Henry, Tracy Lynn

    1995-01-01T23:59:59.000Z

    Automatic vehicle location systems are becoming more prevalent in diverse transportation applications. Their ability to locate vehicles can assist in locating emergency and public transit vehicles for better real-time dispatching as well...

  16. Analysis of the AirTouch automatic vehicle location system's ability to locate moving vehicles

    E-Print Network [OSTI]

    Henry, Tracy Lynn

    1995-01-01T23:59:59.000Z

    Automatic vehicle location systems are becoming more prevalent in diverse transportation applications. Their ability to locate vehicles can assist in locating emergency and public transit vehicles for better real-time dispatching as well...

  17. Tile-based Level of Detail for the Parallel Age

    SciTech Connect (OSTI)

    Niski, K; Cohen, J D

    2007-08-15T23:59:59.000Z

    Today's PCs incorporate multiple CPUs and GPUs and are easily arranged in clusters for high-performance, interactive graphics. We present an approach based on hierarchical, screen-space tiles to parallelizing rendering with level of detail. Adapt tiles, render tiles, and machine tiles are associated with CPUs, GPUs, and PCs, respectively, to efficiently parallelize the workload with good resource utilization. Adaptive tile sizes provide load balancing while our level of detail system allows total and independent management of the load on CPUs and GPUs. We demonstrate our approach on parallel configurations consisting of both single PCs and a cluster of PCs.

  18. Detailed Execution Planning for Large Oil and Gas Construction Projects

    E-Print Network [OSTI]

    Calgary, University of

    Detailed Execution Planning for Large Oil and Gas Construction Projects Presented by James Lozon, University of Calgary There is currently 55.8 billion dollars worth of large oil and gas construction projects scheduled or underway in the province of Alberta. Recently, large capital oil and gas projects

  19. Math 241: Fourier series: details and convergence University of Pennsylvania

    E-Print Network [OSTI]

    DeTurck, Dennis

    Math 241: Fourier series: details and convergence D. DeTurck University of Pennsylvania October 15, 2012 D. DeTurck Math 241 002 2012C: Fourier series 1 / 22 #12;Fourier series We've been using Fourier questions: · Do Fourier series converge? · What do they converge to? Do they converge to the functions we

  20. EMIS Quick User Guide Search page (details on page 2)

    E-Print Network [OSTI]

    Barthelat, Francois

    search terms in foreign languages You can enter search terms in foreign languages by: - Using your: Please note that we have a Cyrillic and Arabic keyboards available through the Search page. EnteringEMIS Quick User Guide Search page (details on page 2) The News page: Access the latest news

  1. Methods for Detailed Energy Data Collection of Miscellaneous

    E-Print Network [OSTI]

    94720 USA b University of California, Berkeley Berkeley, CA 94720 USA Environmental Energy Technologies primary energy consumption in the U.S., with 22% consumed by the residential sector and 18LBNL-6384E Methods for Detailed Energy Data Collection of Miscellaneous and Electronic Loads

  2. Medical Plan Detail Document for Funded Graduate Students

    E-Print Network [OSTI]

    2004-05 Medical Plan Detail Document for Funded Graduate Students Program Provisions for Status Change Medical/Prescription Drug Card Medical Care Outside Ohio Dual Coverage Case Management Managed Health Care Systems (MHCS) 19 How Payment Is Determined 20 Annual Deductible Annual Out

  3. BME 315 Biomechanics Material Properties of Tendon: experimental details

    E-Print Network [OSTI]

    Lakes, Roderic

    . To cut the tendon with minimal damage, angle the cutting edge of the blade away from the tendon so with a known load, we have the calibration factor that we need to determine the load. We will calculate, they can be easily damaged by even the most superficial cuts. Figure 2: Tendons are located around

  4. A 2D Random Walk Mobility Model for Location Management Studies in Wireless Networks

    E-Print Network [OSTI]

    Shenoy, Nirmala

    crossing rate' and `dwell time' studies using the same model with slight modifications for the square cell, namely the square cell and the hexagonal cell have been detailed. The analytical results obtained for location update rates and dwell times have been validated using simulated and published results

  5. Helicopter magnetic survey conducted to locate wells

    SciTech Connect (OSTI)

    Veloski, G.A.; Hammack, R.W.; Stamp, V. (Rocky Mountain Oilfield Testing Center); Hall, R. (Rocky Mountain Oilfield Testing Center); Colina, K. (Rocky Mountain Oilfield Testing Center)

    2008-07-01T23:59:59.000Z

    A helicopter magnetic survey was conducted in August 2007 over 15.6 sq mi at the Naval Petroleum Reserve No. 3’s (NPR-3) Teapot Dome Field near Casper, Wyoming. The survey’s purpose was to accurately locate wells drilled there during more than 90 years of continuous oilfield operation. The survey was conducted at low altitude and with closely spaced flight lines to improve the detection of wells with weak magnetic response and to increase the resolution of closely spaced wells. The survey was in preparation for a planned CO2 flood for EOR, which requires a complete well inventory with accurate locations for all existing wells. The magnetic survey was intended to locate wells missing from the well database and to provide accurate locations for all wells. The ability of the helicopter magnetic survey to accurately locate wells was accomplished by comparing airborne well picks with well locations from an intense ground search of a small test area.

  6. Location theory and the location of industry along an interstate highway

    E-Print Network [OSTI]

    Miller, James Patterson

    1965-01-01T23:59:59.000Z

    to determine the significance of these locational factors among plants with different characteristics that have located in certain localities should provide pertinent information with both practical and theoretical implications. Since 1956, approximately 64... Summary of Plant Location Theory Cost Fac'tots . . . . . . . . . . . . . ~ The Importance of 'the Demand Factor Greenhut's General Theory of Plant Location and the Intangible Factor Location Factors as Revealed by Empirical Study Greenhut's Case...

  7. Towards a detailed soot model for internal combustion engines

    SciTech Connect (OSTI)

    Mosbach, Sebastian; Celnik, Matthew S.; Raj, Abhijeet; Kraft, Markus [Department of Chemical Engineering and Biotechnology, University of Cambridge, Pembroke Street, Cambridge CB2 3RA (United Kingdom); Zhang, Hongzhi R. [Department of Chemical Engineering, University of Utah, 1495 East 100 South, Kennecott Research Building, Salt Lake City, UT 84112 (United States); Kubo, Shuichi [Frontier Research Center, Toyota Central R and D Labs., Inc., Nagakute, Aichi 480-1192 (Japan); Kim, Kyoung-Oh [Higashifuji Technical Center, Toyota Motor Corporation, Mishuku 1200, Susono, Shizuoka 480-1193 (Japan)

    2009-06-15T23:59:59.000Z

    In this work, we present a detailed model for the formation of soot in internal combustion engines describing not only bulk quantities such as soot mass, number density, volume fraction, and surface area but also the morphology and chemical composition of soot aggregates. The new model is based on the Stochastic Reactor Model (SRM) engine code, which uses detailed chemistry and takes into account convective heat transfer and turbulent mixing, and the soot formation is accounted for by SWEEP, a population balance solver based on a Monte Carlo method. In order to couple the gas-phase to the particulate phase, a detailed chemical kinetic mechanism describing the combustion of Primary Reference Fuels (PRFs) is extended to include small Polycyclic Aromatic Hydrocarbons (PAHs) such as pyrene, which function as soot precursor species for particle inception in the soot model. Apart from providing averaged quantities as functions of crank angle like soot mass, volume fraction, aggregate diameter, and the number of primary particles per aggregate for example, the integrated model also gives detailed information such as aggregate and primary particle size distribution functions. In addition, specifics about aggregate structure and composition, including C/H ratio and PAH ring count distributions, and images similar to those produced with Transmission Electron Microscopes (TEMs), can be obtained. The new model is applied to simulate an n-heptane fuelled Homogeneous Charge Compression Ignition (HCCI) engine which is operated at an equivalence ratio of 1.93. In-cylinder pressure and heat release predictions show satisfactory agreement with measurements. Furthermore, simulated aggregate size distributions as well as their time evolution are found to qualitatively agree with those obtained experimentally through snatch sampling. It is also observed both in the experiment as well as in the simulation that aggregates in the trapped residual gases play a vital role in the soot formation process. (author)

  8. Detailed chemical kinetic oxidation mechanism for a biodiesel surrogate

    SciTech Connect (OSTI)

    Herbinet, O; Pitz, W J; Westbrook, C K

    2007-09-20T23:59:59.000Z

    A detailed chemical kinetic mechanism has been developed and used to study the oxidation of methyl decanoate, a surrogate for biodiesel fuels. This model has been built by following the rules established by Curran et al. for the oxidation of n-heptane and it includes all the reactions known to be pertinent to both low and high temperatures. Computed results have been compared with methyl decanoate experiments in an engine and oxidation of rapeseed oil methyl esters in a jet stirred reactor. An important feature of this mechanism is its ability to reproduce the early formation of carbon dioxide that is unique to biofuels and due to the presence of the ester group in the reactant. The model also predicts ignition delay times and OH profiles very close to observed values in shock tube experiments fueled by n-decane. These model capabilities indicate that large n-alkanes can be good surrogates for large methyl esters and biodiesel fuels to predict overall reactivity, but some kinetic details, including early CO{sub 2} production from biodiesel fuels, can be predicted only by a detailed kinetic mechanism for a true methyl ester fuel. The present methyl decanoate mechanism provides a realistic kinetic tool for simulation of biodiesel fuels.

  9. Detailed chemical kinetic oxidation mechanism for a biodiesel surrogate

    SciTech Connect (OSTI)

    Herbinet, O; Pitz, W J; Westbrook, C K

    2007-09-17T23:59:59.000Z

    A detailed chemical kinetic mechanism has been developed and used to study the oxidation of methyl decanoate, a surrogate for biodiesel fuels. This model has been built by following the rules established by Curran et al. for the oxidation of n-heptane and it includes all the reactions known to be pertinent to both low and high temperatures. Computed results have been compared with methyl decanoate experiments in an engine and oxidation of rapeseed oil methyl esters in a jet stirred reactor. An important feature of this mechanism is its ability to reproduce the early formation of carbon dioxide that is unique to biofuels and due to the presence of the ester group in the reactant. The model also predicts ignition delay times and OH profiles very close to observed values in shock tube experiments fueled by n-decane. These model capabilities indicate that large n-alkanes can be good surrogates for large methyl esters and biodiesel fuels to predict overall reactivity, but some kinetic details, including early CO2 production from biodiesel fuels, can be predicted only by a detailed kinetic mechanism for a true methyl ester fuel. The present methyl decanoate mechanism provides a realistic kinetic tool for simulation of biodiesel fuels.

  10. Detailed chemical kinetic oxidation mechanism for a biodiesel surrogate

    SciTech Connect (OSTI)

    Herbinet, Olivier; Pitz, William J.; Westbrook, Charles K. [Lawrence Livermore National Laboratory, Livermore, CA 94550 (United States)

    2008-08-15T23:59:59.000Z

    A detailed chemical kinetic mechanism has been developed and used to study the oxidation of methyl decanoate, a surrogate for biodiesel fuels. This model has been built by following the rules established by Curran and co-workers for the oxidation of n-heptane and it includes all the reactions known to be pertinent to both low and high temperatures. Computed results have been compared with methyl decanoate experiments in an engine and oxidation of rapeseed oil methyl esters in a jet-stirred reactor. An important feature of this mechanism is its ability to reproduce the early formation of carbon dioxide that is unique to biofuels and due to the presence of the ester group in the reactant. The model also predicts ignition delay times and OH profiles very close to observed values in shock tube experiments fueled by n-decane. These model capabilities indicate that large n-alkanes can be good surrogates for large methyl esters and biodiesel fuels to predict overall reactivity, but some kinetic details, including early CO{sub 2} production from biodiesel fuels, can be predicted only by a detailed kinetic mechanism for a true methyl ester fuel. The present methyl decanoate mechanism provides a realistic kinetic tool for simulation of biodiesel fuels. (author)

  11. Low-risk and cost-effective prior savings estimates for large-scale energy conservation projects in housing: Learning from the Fort Polk GHP project

    SciTech Connect (OSTI)

    Shonder, J.A.; Hughes, P.J. [Oak Ridge National Lab., TN (United States); Thornton, J.W. [Thermal Energy Systems Specialists, Inc., Madison, WI (United States)

    1997-08-01T23:59:59.000Z

    Many opportunities exist for large-scale energy conservation projects in housing. Energy savings performance contracting (ESPC) is now receiving greater attention, as a means to implement such projects. This paper proposes an improved method for prior (to construction) savings estimates for these projects. The proposed approach to prior estimates is verified against data from Fort Polk, LA. In the course of evaluating the ESPC at Fort Polk, the authors have collected energy use data which allowed them to develop calibrated engineering models which accurately predict pre-retrofit energy consumption. They believe that such calibrated models could be used to provide much more accurate estimates of energy savings in retrofit projects. The improved savings estimating approach described here is based on an engineering model calibrated to field-collected data from the pre-retrofit period. A dynamic model of pre-retrofit energy use was developed for all housing and non-housing loads on a complete electrical feeder at Fort Polk. The model included the heat transfer characteristics of the buildings, the pre-retrofit air source heat pump, a hot water consumption model and a profile for electrical use by lights and other appliances. Energy consumption for all 200 apartments was totaled, and by adjusting thermostat setpoints and outdoor air infiltration parameters, the models were matched to field-collected energy consumption data for the entire feeder. The energy conservation measures were then implemented in the calibrated model: the air source heat pumps were replaced by geothermal heat pumps with desuperheaters; hot water loads were reduced to account for the low-flow shower heads; and lighting loads were reduced to account for fixture delamping and replacement with compact fluorescent lights. The analysis of pre- and post-retrofit data indicates that the retrofits have saved 30.3% of pre-retrofit electrical energy consumption on the feeder modeled in this paper.

  12. Regenerator Location Problem in Flexible Optical Networks

    E-Print Network [OSTI]

    BARIS YILDIZ

    2014-11-22T23:59:59.000Z

    Nov 22, 2014 ... Abstract: In this study we introduce the regenerator location problem in flexible optical networks (RLP-FON). With a given traffic demand, ...

  13. Impacts of Climate Change on Energy Consumption and Peak Demand in Buildings: A Detailed Regional Approach

    SciTech Connect (OSTI)

    Dirks, James A.; Gorrissen, Willy J.; Hathaway, John E.; Skorski, Daniel C.; Scott, Michael J.; Pulsipher, Trenton C.; Huang, Maoyi; Liu, Ying; Rice, Jennie S.

    2015-01-01T23:59:59.000Z

    This paper presents the results of numerous commercial and residential building simulations, with the purpose of examining the impact of climate change on peak and annual building energy consumption over the portion of the Eastern Interconnection (EIC) located in the United States. The climate change scenario considered (IPCC A2 scenario as downscaled from the CASCaDE data set) has changes in mean climate characteristics as well as changes in the frequency and duration of intense weather events. This investigation examines building energy demand for three annual periods representative of climate trends in the CASCaDE data set at the beginning, middle, and end of the century--2004, 2052, and 2089. Simulations were performed using the Building ENergy Demand (BEND) model which is a detailed simulation platform built around EnergyPlus. BEND was developed in collaboration with the Platform for Regional Integrated Modeling and Analysis (PRIMA), a modeling framework designed to simulate the complex interactions among climate, energy, water, and land at decision-relevant spatial scales. Over 26,000 building configurations of different types, sizes, vintages, and, characteristics which represent the population of buildings within the EIC, are modeled across the 3 EIC time zones using the future climate from 100 locations within the target region, resulting in nearly 180,000 spatially relevant simulated demand profiles for each of the 3 years. In this study, the building stock characteristics are held constant based on the 2005 building stock in order to isolate and present results that highlight the impact of the climate signal on commercial and residential energy demand. Results of this analysis compare well with other analyses at their finest level of specificity. This approach, however, provides a heretofore unprecedented level of specificity across multiple spectrums including spatial, temporal, and building characteristics. This capability enables the ability to perform detailed hourly impact studies of building adaptation and mitigation strategies on energy use and electricity peak demand within the context of the entire grid and economy.

  14. Automated Fault Location In Smart Distribution Systems 

    E-Print Network [OSTI]

    Lotfifard, Saeed

    2012-10-19T23:59:59.000Z

    ............................................................................................................................ 88 x LIST OF FIGURES Page Figure 1 Multiple possible fault location estimation for a fault at node A ........................ 7 Figure 2 Simple faulted network model [1] © [2011] IEEE ............................................ 40 Figure 3... Types C and D voltage sags for different phases [51] © [2003] IEEE .............. 42 Figure 4 Rf estimation procedure [1] © [2011] IEEE ...................................................... 45 Figure 5 Flow chart of the fault location algorithm [1...

  15. RECYCLING PROGRAM TYPE LOCATION ALLOWED NOT ALLOWED

    E-Print Network [OSTI]

    Miami, University of

    RECYCLING PROGRAM TYPE LOCATION ALLOWED NOT ALLOWED Batteries, toner, ink cartridges & cell phones and recycling is an important part of that effort. Below is a guide to on-campus recycling at RSMAS: Visit http://www.rsmas.miami.edu/msgso/ for map of recycling bin locations. NOTE: This is not an exhaustive list. If unauthorized items are found

  16. Optimized Fault Location Final Project Report

    E-Print Network [OSTI]

    Engineering Research Center Optimized Fault Location Concurrent Technologies Corporation Final Project Report by the Concurrent Technologies Corporation (CTC) and the Power Systems Engineering Research Center (PSERC). NeitherOptimized Fault Location Final Project Report Power Systems Engineering Research Center A National

  17. Locating and tracking assets using RFID 

    E-Print Network [OSTI]

    Kim, Gak Gyu

    2009-05-15T23:59:59.000Z

    , this research presents a math¬ematical model of using RFID (both handheld readers and stationary readers) for e?cient asset location. We derive the expected cost of locating RFID¬tagged objects in a multi¬area environment where hand¬held RF readers are used. We...

  18. Location Privacy and the Personal Distributed Environment

    E-Print Network [OSTI]

    Atkinson, Robert C

    Location Privacy and the Personal Distributed Environment Robert C Atkinson, Swee Keow Goo, James-- The Personal Distributed Environment is a new concept being developed within the Mobile VCE Core 3 research, wherever their location: ubiquitous access. Devices are co-ordinated by Device Management Entities (DMEs

  19. Center for Imaging Science Job Opportunities www.cis.rit.edu/jobs The CIS office does not have any more details on the external postings listed here.

    E-Print Network [OSTI]

    Zanibbi, Richard

    . · Experience in low-noise switch-capacitor circuit design necessary. · Experience in layout is required more details on the external postings listed here. Senior Analog/Mixed-Signal Design Engineer Location: Irvine, CA Description: This role involves design and execution of circuits related to CMOS Image Sensor

  20. Detailed balance limit of power conversion efficiency for organic photovoltaics

    SciTech Connect (OSTI)

    Seki, Kazuhiko, E-mail: k-seki@aist.go.jp [NRI, National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, Higashi 1-1-1, Tsukuba, Ibaraki 305-8565 (Japan)] [NRI, National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, Higashi 1-1-1, Tsukuba, Ibaraki 305-8565 (Japan); Furube, Akihiro [RIIF, AIST Tsukuba Central 2, Umezono 1-1-1, Tsukuba, Ibaraki 305-8568 (Japan)] [RIIF, AIST Tsukuba Central 2, Umezono 1-1-1, Tsukuba, Ibaraki 305-8568 (Japan); Yoshida, Yuji [RCPVT, National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, Higashi 1-1-1, Tsukuba, Ibaraki 305-8565 (Japan)] [RCPVT, National Institute of Advanced Industrial Science and Technology (AIST), AIST Tsukuba Central 5, Higashi 1-1-1, Tsukuba, Ibaraki 305-8565 (Japan)

    2013-12-16T23:59:59.000Z

    A fundamental difference between inorganic photovoltaic (IPV) and organic photovoltaic (OPV) cells is that charges are generated at the interface in OPV cells, while free charges can be generated in the bulk in IPV cells. In OPV cells, charge generation involves intrinsic energy losses to dissociate excitons at the interface between the donor and acceptor. By taking into account the energy losses, we show the theoretical limits of the power conversion efficiency set by radiative recombination of the carriers on the basis of the detailed balance relation between radiation from the cell and black-body radiation.

  1. Detailed Chemical Analysis of Two Giants in the SGR DSPH

    E-Print Network [OSTI]

    P. Bonifacio; P. Molaro

    2001-01-23T23:59:59.000Z

    The 8m class telescopes allow for the first time to study stars of external galaxies with the same resolution and S/N ratio which has been so far used for Galactic stars. It is quite likely that this study will shake some of our current beliefs. In this poster we highlight some of the results which have been obtained for two giants in the Sgr dSph thanks to the UVES spectrograph on the ESO 8.2m Kueyen telescope. Further details on the observations and data analysis may be found in Bonifacio et al (2000).

  2. PROJECT MANGEMENT PLAN EXAMPLES Prepare Detailed Work Packages Examples

    Broader source: Energy.gov (indexed) [DOE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742Energy ChinaofSchaeferAprilOverviewEfficiencyofHSSPIA -HazardFeedback Examples Example 74Detailed

  3. Electric Utility Sales and Revenue - EIA-826 detailed data file

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645U.S. DOEThe Bonneville Power AdministrationField Campaign:INEAWater Use Goal 4:Administration826 detailed data The

  4. Detailed Physical Trough Model for NREL's Solar Advisor Model: Preprint

    SciTech Connect (OSTI)

    Wagner, M. J.; Blair, N.; Dobos, A.

    2010-10-01T23:59:59.000Z

    Solar Advisor Model (SAM) is a free software package made available by the National Renewable Energy Laboratory (NREL), Sandia National Laboratory, and the US Department of Energy. SAM contains hourly system performance and economic models for concentrating solar power (CSP) systems, photovoltaic, solar hot-water, and generic fuel-use technologies. Versions of SAM prior to 2010 included only the parabolic trough model based on Excelergy. This model uses top-level empirical performance curves to characterize plant behavior, and thus is limited in predictive capability for new technologies or component configurations. To address this and other functionality challenges, a new trough model; derived from physical first principles was commissioned to supplement the Excelergy-based empirical model. This new 'physical model' approaches the task of characterizing the performance of the whole parabolic trough plant by replacing empirical curve-fit relationships with more detailed calculations where practical. The resulting model matches the annual performance of the SAM empirical model (which has been previously verified with plant data) while maintaining run-times compatible with parametric analysis, adding additional flexibility in modeled system configurations, and providing more detailed performance calculations in the solar field, power block, piping, and storage subsystems.

  5. Detailed computation of hot-plasma atomic spectra

    E-Print Network [OSTI]

    Pain, Jean-Christophe; Blenski, Thomas

    2015-01-01T23:59:59.000Z

    We present recent evolutions of the detailed opacity code SCO-RCG which combines statistical modelings of levels and lines with fine-structure calculations. The code now includes the Partially-Resolved-Transition-Array model, which allows one to replace a complex transition array by a small-scale detailed calculation preserving energy and variance of the genuine transition array and yielding improved high-order moments. An approximate method for studying the impact of strong magnetic field on opacity and emissivity was also recently implemented. The Zeeman line profile is modeled by fourth-order Gram-Charlier expansion series, which is a Gaussian multiplied by a linear combination of Hermite polynomials. Electron collisional line broadening is often modeled by a Lorentzian function and one has to calculate the convolution of a Lorentzian with Gram-Charlier distribution for a huge number of spectral lines. Since the numerical cost of the direct convolution would be prohibitive, we propose, in order to obtain t...

  6. Detailed microearthquake survey of Long Valley, California, known geothermal resource area, July-September 1981. Final technical report, 30 September 1980-31 June 1983

    SciTech Connect (OSTI)

    Cramer, C.H.; Stierman, D.J.; Lee, T.C.

    1983-07-01T23:59:59.000Z

    This report presents the results of a detailed microearthquake survey of the geothermal area at Long Valley, California. High quality digital data from a dense 3-component array covering a three-month period during the summer of 1981 have been processed for locations, velocity structure, magnitudes, focal mechanisms, and source parameters. Hypocenter locations determined from this array have estimated errors of 0.5 km in epicenter and 1.0 km in depth relative to one another. Detailed hypocentral locations show two complex zones of seismicity beneath the south moat of the caldera which seems associated with the major hot spring activity within the caldera and could be part of the conduit system feeding hydrothermal waters to these hot springs. Seismic activity at Long Valley appears to be influenced by both regional tectonic stresses and local volcanotectonic activity.

  7. The Construction of Locative Situations: Locative Media and the Situationist International, Recuperation or Redux?

    E-Print Network [OSTI]

    McGarrigle, Conor

    2009-01-01T23:59:59.000Z

    closely aligned to the SI's construction of situations. ThisG (1957) Report on the Construction of Situations and on theThe Construction of Locative Situations: Locative Media and

  8. SFSU Building Coordinators List College or Administrative Unit Location(s)

    E-Print Network [OSTI]

    SFSU Building Coordinators List College or Administrative Unit Location(s) Building Coordinator81193 cathym@sfsu.edu GYM 102B Student Services Building SSB Mirel Tikkanen x53566 mtikkane@sfsu.edu SSB

  9. Method of locating underground mines fires

    DOE Patents [OSTI]

    Laage, Linneas (Eagam, MN); Pomroy, William (St. Paul, MN)

    1992-01-01T23:59:59.000Z

    An improved method of locating an underground mine fire by comparing the pattern of measured combustion product arrival times at detector locations with a real time computer-generated array of simulated patterns. A number of electronic fire detection devices are linked thru telemetry to a control station on the surface. The mine's ventilation is modeled on a digital computer using network analysis software. The time reguired to locate a fire consists of the time required to model the mines' ventilation, generate the arrival time array, scan the array, and to match measured arrival time patterns to the simulated patterns.

  10. THE PLANAR HUB LOCATION PROBLEM: A PROBABILISTIC ...

    E-Print Network [OSTI]

    2012-11-21T23:59:59.000Z

    Nov 5, 2012 ... Aykin and Brown, [4]. ...... [8] J.F. Campbell, Integer programming formulations of discrete hub location problems, European J. of O.R.. 72(1994) ...

  11. Developing a theory of nightclub location choice

    E-Print Network [OSTI]

    Crim, Stephen J. (Stephen Johnson)

    2008-01-01T23:59:59.000Z

    This work is an investigation of the factors that influence where nightclubs locate within a city. Nightclubs, like other social spaces, provide important social and economic benefits in the urban environment. As amenities, ...

  12. Techniques for Mobile Location Estimation in UMTS 

    E-Print Network [OSTI]

    Thomas, Nicholas J

    The subject area of this thesis is the locating of mobile users using the future 3rd generation spread spectrum communication system UMTS. The motivation behind this work is twofold: firstly the United States Federal ...

  13. Driver expectancy in locating automotive controls 

    E-Print Network [OSTI]

    Francis, Dawn Suzette

    1990-01-01T23:59:59.000Z

    DRIVER EXPECTANCY IN LOCATING AUTOMOTIVE CONTROLS A Thesis by DAWN SUZETTE FRANCIS Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE May 1990... Major Subject: Industrial Engineering DRIVER EXPECTANCY IN LOCATING AUTOMOTIVE CONTROLS A Thesis by DAWN SUZETTE FRANCIS Approved as to style and content by: R. Dale Huchi son (Chair of Committee) Rodger . . ppa (Member) Waymon L ohnston (M er...

  14. Driver expectancy in locating automotive controls

    E-Print Network [OSTI]

    Francis, Dawn Suzette

    1990-01-01T23:59:59.000Z

    Major Subject: Industrial Engineering DRIVER EXPECTANCY IN LOCATING AUTOMOTIVE CONTROLS A Thesis by DAWN SUZETTE FRANCIS Approved as to style and content by: R. Dale Huchi son (Chair of Committee) Rodger . . ppa (Member) Waymon L ohnston (M er... assessment of automotive industry practices in 1971 and concluded that only 50% of controls/displays on various models could be said to have a common location. Perel (1974) reviewed prior research and found that it would be difficult to pinpoint...

  15. Locating Boosted Kerr and Schwarzschild Apparent Horizons

    E-Print Network [OSTI]

    Mijan F. Huq; Matthew W. Choptuik; Richard A. Matzner

    2000-02-22T23:59:59.000Z

    We describe a finite-difference method for locating apparent horizons and illustrate its capabilities on boosted Kerr and Schwarzschild black holes. Our model spacetime is given by the Kerr-Schild metric. We apply a Lorentz boost to this spacetime metric and then carry out a 3+1 decomposition. The result is a slicing of Kerr/Schwarzschild in which the black hole is propagated and Lorentz contracted. We show that our method can locate distorted apparent horizons efficiently and accurately.

  16. Evolution Effects on Parton Energy Loss with Detailed Balance

    E-Print Network [OSTI]

    Luan cheng; Enke Wang

    2010-04-30T23:59:59.000Z

    The initial conditions in the chemical non-equilibrated medium and Bjorken expanding medium at RHIC are determined. With a set of rate equations describing the chemical equilibration of quarks and gluons based on perturbative QCD, we investigate the consequence for parton evolution at RHIC. With considering parton evolution, it is shown that the Debye screening mass and the inverse mean free-path of gluons reduce with increasing proper time in the QGP medium. The parton evolution affects the parton energy loss with detailed balance, both parton energy loss from stimulated emission in the chemical non-equilibrated expanding medium and in Bjorken expanding medium are linear dependent on the propagating distance rather than square dependent in the static medium. The energy absorption can not be neglected at intermediate jet energies and small propagating distance of the energetic parton in contrast with that it is important only at intermediate jet energy in the static medium. This will increase the energy and propagating distance dependence of the parton energy loss and will affect the shape of suppression of moderately high P_T hadron spectra.

  17. Flow Effects on Jet Energy Loss with Detailed Balance

    E-Print Network [OSTI]

    Luan Cheng; Jia Liu; Enke Wang

    2014-06-03T23:59:59.000Z

    In the presence of collective flow a new model potential describing the interaction of the hard jet with scattering centers is derived based on the static color-screened Yukawa potential. The flow effect on jet quenching with detailed balance is investigated in pQCD. It turns out, considering the collective flow with velocity $v_z$ along the jet direction, the collective flow decreases the LPM destructive interference comparing to that in the static medium. The gluon absorption plays a more important role in the moving medium. The collective flow increases the energy gain from gluon absorption, however, decreases the energy loss from gluon radiation, which is $(1 - v_z )$ times as that in the static medium to the first order of opacity. In the presence of collective flow, the second order in opacity correction is relatively small compared to the first order. So that the total effective energy loss is decreased. The flow dependence of the energy loss will affect the suppression of high $p_T$ hadron spectrum and anisotropy parameter $v_2$ in high-energy heavy-ion collisions.

  18. A detail study of defect models for cosmic structure formation

    E-Print Network [OSTI]

    A. Albrecht; R. A. Battye; J. Robinson

    1997-11-27T23:59:59.000Z

    We calculate predictions from wide class of `active' models of cosmic structure formation which allows us to scan the space of possible defect models. We calculate the linear cold dark matter power spectrum and Cosmic Microwave Background (CMB) anisotropies over all observable scales using a full linear Einstein-Boltzmann code. Our main result, which has already been reported, points to a serious problem reconciling the observed amplitude of the large-scale galaxy distribution with the COBE normalization. Here, we describe our methods and results in detail. The problem is present for a wide range of defect parameters, which can be used to represent potential differences among defect models, as well as possible systematic numerical errors. We explicitly examine the impact of varying the defect model parameters and we show how the results substantiate these conclusions. The standard scaling defect models are in serious conflict with the current data, and we show how attempts to resolve the problem by considering non-scaling defects or modified stress-energy components would require radical departures from what has become the standard picture.

  19. GRB 050822: Detailed analysis of an XRF observed by Swift

    E-Print Network [OSTI]

    Godet, O; Osborne, J; Zhang, B; Burrows, D N; O'Brien, P T; Hill, J E; Racusin, J; Beardmore, A P; Goad, M R; Falcone, A; Morris, D C; Ziaeepour, H

    2007-01-01T23:59:59.000Z

    We report on the temporal and spectral characteristics of the early X-ray emission from the GRB 050822 as observed by Swift. This burst is likely to be an XRF showing major X-ray flares in its XRT light-curve. The quality of the data allows a detailed spectral analysis of the early afterglow in the X-ray band. During the X-ray flares, a positive correlation between the count rate and the spectral hardness (i.e. higher the count rate is and harder the spectrum is) is clearly seen for the X-ray flares. This behaviour similar to that seen for Gamma-ray pulses indicates that the energy peak of the spectrum is in the XRT energy band and it moves at lower energy with time. We show evidence for the possible detection of the emergence of the forward-shock emission produced at a radius larger than 4 x 10^{16} cm (a forming region clearly different to that producing the prompt emission). Finally, we show that the null detection of a jet break up to T_0+4 x 10^6s in the X-ray light curve of this XRF can be understood: i...

  20. Detailed model for practical pulverized coal furnaces and gasifiers

    SciTech Connect (OSTI)

    Philips, S.D.; Smoot, L.D.

    1989-08-01T23:59:59.000Z

    The need to improve efficiency and reduce pollutant emissions commercial furnaces has prompted energy companies to search for optimized operating conditions and improved designs in their fossil-fuel burning facilities. Historically, companies have relied on the use of empirical correlations and pilot-plant data to make decisions about operating conditions and design changes. The high cost of collecting data makes obtaining large amounts of data infeasible. The main objective of the data book is to provide a single source of detailed three-dimensional combustion and combustion-related data suitable for comprehensive combustion model evaluation. Five tasks were identified as requirements to achieve the main objective. First, identify the types of data needed to evaluate comprehensive combustion models, and establish criteria for selecting the data. Second, identify and document available three-dimensional combustion data related to pulverized coal combustion. Third, collect and evaluate three-dimensional data cases, and select suitable cases based on selection criteria. Fourth, organize the data sets into an easy-to-use format. Fifth, evaluate and interpret the nature and quality of the data base. 39 refs., 15 figs., 14 tabs.

  1. Low-Risk and Cost-Effective Prior Savings Estimates for Large-Scale Energy Conservation Projects in Housing: Learning from the Fort Polk GHP Project

    SciTech Connect (OSTI)

    Shonder, John A [ORNL; Hughes, Patrick [ORNL; Thornton, Jeff W. [Thermal Energy Systems Specialists, Inc.

    1997-08-01T23:59:59.000Z

    Many opportunities exist for large-scale energy conservation projects in housing: military housing, federally-subsidized low-income housing, and planned communities (condominiums, townhomes, senior centers) to name a few. Energy savings performance contracting (ESPC) is now receiving greater attention, as a means to implement such projects. This paper proposes an improved method for prior (to construction) savings estimates for these projects. More accurate prior estimates reduce project risk, decrease financing costs, and help avoid post-construction legal disputes over performance contract baseline adjustments. The proposed approach to prior estimates is verified against data from Fort Polk, LA. In the course of evaluating the ESPC at Fort Polk, Louisiana, we have collected energy use data - both at the electrical feeder level and at the level of individual residences - which allowed us to develop calibrated engineering models which accurately predict pre-retrofit energy consumption. We believe that such calibrated models could be used to provide much more accurate estimates of energy savings in retrofit projects, particularly in cases where the energy consumption of large populations of housing can be captured on one or a few meters. The improved savings estimating approach described here is based on an engineering model calibrated to field-collected data from the pre-retrofit period. A dynamic model of pre-retrofit energy use was developed for all housing and non-housing loads on a complete electrical feeder at Fort Polk. The feeder serves 46 buildings containing a total of 200 individual apartments. Of the 46 buildings, there are three unique types, and among these types the only difference is compass orientation. The model included the heat transfer characteristics of the buildings, the pre-retrofit air source heat pump, a hot water consumption model and a profile for electrical use by lights and other appliances. Energy consumption for all 200 apartments was totaled, and by adjusting thermostat setpoints and outdoor air infiltration parameters, the models were matched to field-collected energy consumption data for the entire feeder. The energy conservation measures were then implemented in the calibrated model: the air source heat pumps were replaced by geothermal heat pumps (GHPs) with desuperheaters; hot water loads were reduced to account for the low-flow shower heads; and lighting loads were reduced to account for fixture delamping and replacement with compact fluorescent lights (CFLs). Our analysis of pre- and post-retrofit data (Shonder and Hughes, 1997) indicates that the retrofits have saved 30.3% of pre-retrofit electrical energy consumption on the feeder modeled in this paper. Using the method outlined, we have been able to predict this savings within 0.1% of its measured value, using only pre-construction energy consumption data, and data from one pilot test site. It is well-known that predictions of savings from energy conservation programs are often optimistic, especially in the case of residential retrofits. Fels and keating (1993) cite several examples of programs which achieved as little as 20% of the predicted energy savings. Factors which influence the sometimes large discrepancies between actual and predicted savings include changes in occupancy, take-back effects (in which more efficient system operation leads occupants to choose higher levels of comfort), and changes in base energy use (e.g. through purchase of additional appliances such as washing machines and clothes dryers). An even larger factor, perhaps, is the inaccuracy inherent in the engineering models (BLAST, DOE-2, etc.) commonly used to estimate building energy consumption, if these models are not first calibrated to site-monitored data. For example, prior estimates of base-wide savings from the Fort Polk ESPC were on the order of 40% of pre-retrofit electrical use; our analysis has shown the true savings for the entire project (which includes 16 separate electrical feeders) to be about 32%. It should be noted that the retrofits ca

  2. Reconstructing Spatial Distributions from Anonymized Locations

    SciTech Connect (OSTI)

    Horey, James L [ORNL] [ORNL; Forrest, Stephanie [University of New Mexico, Albuquerque] [University of New Mexico, Albuquerque; Groat, Michael [University of New Mexico, Albuquerque] [University of New Mexico, Albuquerque

    2012-01-01T23:59:59.000Z

    Devices such as mobile phones, tablets, and sensors are often equipped with GPS that accurately report a person's location. Combined with wireless communication, these devices enable a wide range of new social tools and applications. These same qualities, however, leave location-aware applications vulnerable to privacy violations. This paper introduces the Negative Quad Tree, a privacy protection method for location aware applications. The method is broadly applicable to applications that use spatial density information, such as social applications that measure the popularity of social venues. The method employs a simple anonymization algorithm running on mobile devices, and a more complex reconstruction algorithm on a central server. This strategy is well suited to low-powered mobile devices. The paper analyzes the accuracy of the reconstruction method in a variety of simulated and real-world settings and demonstrates that the method is accurate enough to be used in many real-world scenarios.

  3. Location theory and the location of industry along an interstate highway 

    E-Print Network [OSTI]

    Miller, James Patterson

    1965-01-01T23:59:59.000Z

    a greater gamble. This sect. ion has been devoted to s review of the fundamental factors underlying all plant location ss recognised in location theory. The next section will review some recent. empirical attempts to determine the actual... for this thesis was possible through the assistance provided )ointly by the Texas Highway Department and the Bureau of Public Roads. i. v TABLE OF CONTENTS Chapter Page INTRODUCTION Purpose Plan of Study REVIEW OF PLANT LOCATION CONCEPTS Introduction...

  4. Methodology for Use of Reclaimed Water at Federal Locations

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels DataDepartment of Energy Your Density Isn't YourTransport(FactDepartment3311, 3312), OctoberMayEnergy MetalProgramFiscalMethanegasFort

  5. Utility Locating in the DOE Environment

    SciTech Connect (OSTI)

    Clark Scott; Gail Heath

    2006-04-01T23:59:59.000Z

    Some advances have been made in utility locating in recent years and standards have been recently published to try and categorize the level of information known about the utility in the subsurface. At the same time some characterization about the level of effort or technology in the geophysicist approach to utility locating may be generalized. The DOE environment poses some added difficulties and this presentation covers these issues, costs and the technical approach that has been developed at the INEEL to prevent utility hits and how it fits into the generalized classification of effort.

  6. RISK ASSESSMENT FORM FIELD / LOCATION WORK

    E-Print Network [OSTI]

    Lummaa, Virpi

    the work. Detail such risks in the final section. ENVIRONMENT The environment always represents a safety weather, illness, hypothermia, assault, getting lost. Is the risk high/medium/low? CONTROL MEASURES environment trained leaders accompany the trip refuge is available work in outside organisations is subject

  7. Enabling Detailed Energy Analyses via the Technology Performance Exchange: Preprint

    SciTech Connect (OSTI)

    Studer, D.; Fleming, K.; Lee, E.; Livingood, W.

    2014-08-01T23:59:59.000Z

    One of the key tenets to increasing adoption of energy efficiency solutions in the built environment is improving confidence in energy performance. Current industry practices make extensive use of predictive modeling, often via the use of sophisticated hourly or sub-hourly energy simulation programs, to account for site-specific parameters (e.g., climate zone, hours of operation, and space type) and arrive at a performance estimate. While such methods are highly precise, they invariably provide less than ideal accuracy due to a lack of high-quality, foundational energy performance input data. The Technology Performance Exchange was constructed to allow the transparent sharing of foundational, product-specific energy performance data, and leverages significant, external engineering efforts and a modular architecture to efficiently identify and codify the minimum information necessary to accurately predict product energy performance. This strongly-typed database resource represents a novel solution to a difficult and established problem. One of the most exciting benefits is the way in which the Technology Performance Exchange's application programming interface has been leveraged to integrate contributed foundational data into the Building Component Library. Via a series of scripts, data is automatically translated and parsed into the Building Component Library in a format that is immediately usable to the energy modeling community. This paper (1) presents a high-level overview of the project drivers and the structure of the Technology Performance Exchange; (2) offers a detailed examination of how technologies are incorporated and translated into powerful energy modeling code snippets; and (3) examines several benefits of this robust workflow.

  8. Human Factors Considerations in New Nuclear Power Plants: Detailed Analysis.

    SciTech Connect (OSTI)

    OHara,J.; Higgins, J.; Brown, W.; Fink, R.

    2008-02-14T23:59:59.000Z

    This Nuclear Regulatory Commission (NRC) sponsored study has identified human-performance issues in new and advanced nuclear power plants. To identify the issues, current industry developments and trends were evaluated in the areas of reactor technology, instrumentation and control technology, human-system integration technology, and human factors engineering (HFE) methods and tools. The issues were organized into seven high-level HFE topic areas: Role of Personnel and Automation, Staffing and Training, Normal Operations Management, Disturbance and Emergency Management, Maintenance and Change Management, Plant Design and Construction, and HFE Methods and Tools. The issues where then prioritized into four categories using a 'Phenomena Identification and Ranking Table' methodology based on evaluations provided by 14 independent subject matter experts. The subject matter experts were knowledgeable in a variety of disciplines. Vendors, utilities, research organizations and regulators all participated. Twenty issues were categorized into the top priority category. This Brookhaven National Laboratory (BNL) technical report provides the detailed methodology, issue analysis, and results. A summary of the results of this study can be found in NUREG/CR-6947. The research performed for this project has identified a large number of human-performance issues for new control stations and new nuclear power plant designs. The information gathered in this project can serve as input to the development of a long-term strategy and plan for addressing human performance in these areas through regulatory research. Addressing human-performance issues will provide the technical basis from which regulatory review guidance can be developed to meet these challenges. The availability of this review guidance will help set clear expectations for how the NRC staff will evaluate new designs, reduce regulatory uncertainty, and provide a well-defined path to new nuclear power plant licensing.

  9. Preliminary evaluation of crisis-relocation fallout-shelter options. Volume 2. Detailed analysis

    SciTech Connect (OSTI)

    Santini, D.J.; Clinch, J.M.; Davis, F.H.; Hill, L.G.; Lynch, E.P.; Tanzman, E.A.; Wernette, D.R.

    1982-12-01T23:59:59.000Z

    This report presents a preliminary, detailed evaluation of various shelter options for use if the President orders crisis relocation of the US urban population because of strong expectation of a nuclear war. The availability of livable shelter space at 40 ft/sup 2/ per person (congregate-care space) by state is evaluated. Options are evaluated for construction of fallout shelters allowing 10 ft/sup 2/ per person - such shelters are designed to provide 100% survival at projected levels of radioactive fallout. The FEMA concept of upgrading existing buildings to act as fallout shelters can, in principle, provide adequate shelter throughout most of the US. Exceptions are noted and remedies proposed. In terms of upgrading existing buildings to fallout shelter status, great benefits are possible by turning away from a standard national approach and adopting a more site-specific approach. Existing FEMA research provides a solid foundation for successful crisis relocation planning, but the program can be refined by making suitable modifications in its locational, engineering, and institutionally specific elements.

  10. Preliminary environmental assessment for the Satellite Power System (SPS). Revision 1. Volume 2. Detailed assessment

    SciTech Connect (OSTI)

    Not Available

    1980-01-01T23:59:59.000Z

    The Department of Energy (DOE) is considering several options for generating electrical power to meet future energy needs. The satellite power system (SPS), one of these options, would collect solar energy through a system of satellites in space and transfer this energy to earth. A reference system has been described that would convert the energy to microwaves and transmit the microwave energy via directive antennas to large receiving/rectifying antennas (rectennas) located on the earth. At the rectennas, the microwave energy would be converted into electricity. The potential environmental impacts of constructing and operating the satellite power system are being assessed as a part of the Department of Energy's SPS Concept Development and Evaluation Program. This report is Revision I of the Preliminary Environmental Assessment for the Satellite Power System published in October 1978. It refines and extends the 1978 assessment and provides a basis for a 1980 revision that will guide and support DOE recommendations regarding future SPS development. This is Volume 2 of two volumes. It contains the technical detail suitable for peer review and integrates information appearing in documents referenced herein. The key environmental issues associated with the SPS concern human health and safety, ecosystems, climate, and electromagnetic systems interactions. In order to address these issues in an organized manner, five tasks are reported: (I) microwave-radiation health and ecological effects; (II) nonmicrowave health and ecological effectss; (III) atmospheric effects; (IV) effects on communication systems due to ionospheric disturbance; and (V) electromagnetic compatibility. (WHK)

  11. Locating and tracking assets using RFID

    E-Print Network [OSTI]

    Kim, Gak Gyu

    2009-05-15T23:59:59.000Z

    . . . . . . . . . . . . . . . . . . . . . . . . 10 C. Different Technologies for Asset Tracking / Locating . . . . 10 1. Hand-held Reader . . . . . . . . . . . . . . . . . . . . 11 2. Fixed Reader Installed in Area . . . . . . . . . . . . . 11 3. Fixed Reader Installed at Chokepoint... . . . . . . . . . . . 34 a. CaseofInstallingtheFixedReaderintheMost Probable Area . . . . . . . . . . . . . . . . . . . . 35 b. Case of Installing the Fixed Reader in the Far- thest Area . . . . . . . . . . . . . . . . . . . . . . 36 3. Extension of Experiments...

  12. Recycling Bin Guide Locations and prices

    E-Print Network [OSTI]

    Kirschner, Denise

    Recycling Bin Guide Locations and prices Metal Bins Deskside Bins with Side Saddle Rubbermaid Bins.58 for auxiliaries. And Non-Public Areas Public Offices Non-Public Recyclables Recyclables RecyclablesTrash Trash Trash #12;New Recycling Bin Guidelines Frequently Asked Questions (as of December 2008) · Why

  13. Ontology-based Disambiguation of Spatiotemporal Locations

    E-Print Network [OSTI]

    Hyvönen, Eero

    , in the semantic portal MuseumFinland3 [7] a location parton- omy4 was used for annotating museum artifacts. #12;A problem when creating a semantic cultural heritage portal is that places, both modernFinland originate from regions that no longer exist and/or are not part of Finland but of Russia with new names

  14. Transportation Networks and Location A Geometric Approach

    E-Print Network [OSTI]

    Palop del Río, Belén

    Transportation Networks and Location A Geometric Approach Belén Palop1,2 1Departamento de March 2009 Florida State University #12;Belén Palop, UVa, SUNY Outline Transportation Network Model;Transportation Network Model Belén Palop, UVa, SUNY Outline Transportation Network Model Network placement

  15. Exact Location : Date of Accident : AM PM

    E-Print Network [OSTI]

    Swaddle, John

    SSN Cell Phone Home Phone Work Phone Exact Location : Date of Accident : AM PM Date accident treatment provided? Yes No Where Was time lost from work? Yes No If yes, how long? Could this accident have the following information as soon as it relates to your work related accident/injury/illness within 72 hours

  16. RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY

    E-Print Network [OSTI]

    Levinson, David M.

    RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY UC Davis-Caltrans Air control measure. #12;RESIDENTIAL LOCATION CHOICE AND TRAVEL BEHAVIOR: IMPLICATIONS FOR AIR QUALITY.......................................................... 3 2.2 The Role of Residential Location Choice

  17. VCSEL fault location apparatus and method

    DOE Patents [OSTI]

    Keeler, Gordon A. (Albuquerque, NM); Serkland, Darwin K. (Albuquerque, NM)

    2007-05-15T23:59:59.000Z

    An apparatus for locating a fault within an optical fiber is disclosed. The apparatus, which can be formed as a part of a fiber-optic transmitter or as a stand-alone instrument, utilizes a vertical-cavity surface-emitting laser (VCSEL) to generate a test pulse of light which is coupled into an optical fiber under test. The VCSEL is subsequently reconfigured by changing a bias voltage thereto and is used as a resonant-cavity photodetector (RCPD) to detect a portion of the test light pulse which is reflected or scattered from any fault within the optical fiber. A time interval .DELTA.t between an instant in time when the test light pulse is generated and the time the reflected or scattered portion is detected can then be used to determine the location of the fault within the optical fiber.

  18. Automated Fault Location In Smart Distribution Systems

    E-Print Network [OSTI]

    Lotfifard, Saeed

    2012-10-19T23:59:59.000Z

    Quality Meters (PQM), are installed to capture harmonics and certain disturbances for analyzing the power quality indices. Digital Protective Relays are utilized to detect occurrence of the faults and isolate faulted section as fast as possible. Digital... Protective Relays) use synchronous methods [28]. Therefore, if the available data is provided by RTUs, fault location methods that operate based on direct comparison of the input samples cannot be 17 utilized. However, if the data could be gathered from...

  19. Evaluation of workplace air monitoring locations

    SciTech Connect (OSTI)

    Stoetzel, G.A.; Cicotte, G.R.; Lynch, T.P. (Pacific Northwest Lab., Richland, WA (United States)); Aldrich, L.K. (Westinghouse Hanford Co., Richland, WA (United States))

    1991-10-01T23:59:59.000Z

    Current federal guidance on occupational radiation protection recognizes the importance of conducting air flow studies to assist in the placement of air sampling and monitoring equipment. In support of this, Pacific Northwest Laboratory has provided technical assistance to Westinghouse Hanford Company for the purpose of evaluating the adequacy of air sampling and monitoring locations at selected Hanford facilities. Qualitative air flow studies were performed using smoke aerosols to visually determine air movement. Three examples are provided of how air flow studies results, along with information on the purpose of the air sample being collected, were used as a guide in placing the air samplers and monitors. Preparatory steps in conducting an air flow study should include: (1) identifying type of work performed in the work area including any actual or potential release points; (2) determining the amounts of radioactive material available for release and its chemical and physical form; (3) obtaining accurate work area descriptions and diagrams; (4) identifying the location of existing air samplers and monitors; (5) documenting physical and ventilation configurations; (6) notifying appropriate staff of the test; and (7) obtaining necessary equipment and supplies. The primary steps in conducting an air flow study are measurements of air velocities in the work area, release of the smoke aerosol at selected locations in the work area and the observation of air flow patterns, and finally evaluation and documentation of the results. 2 refs., 3 figs.

  20. Save Energy Now Assessments Results 2008 Detailed Report

    SciTech Connect (OSTI)

    Wright, Anthony L [ORNL; Martin, Michaela A [ORNL; Nimbalkar, Sachin U [ORNL; Quinn, James [U.S. Department of Energy; Glatt, Ms. Sandy [DOE Industrial Technologies Program; Orthwein, Mr. Bill [U.S. Department of Energy

    2010-09-01T23:59:59.000Z

    In October 2005, U.S. Department of Energy Secretary Bodman launched his Easy Ways to Save Energy campaign with a promise to provide energy assessments to 200 of the largest U.S. manufacturing plants. DOE's Industrial Technologies Program (ITP) responded to the Secretary's campaign with its Save Energy Now initiative, featuring a new and highly cost-effective form of energy savings assessment. The approach for these assessments drew heavily on the existing resources of ITP's technology delivery component. Over the years, ITP Technology Delivery has worked with industry partners to assemble a suite of respected software tools, proven assessment protocols, training curricula, certified energy experts, and strong partnerships for deployment. The Save Energy Now assessments conducted in calendar year 2006 focused on natural gas savings and targeted many of the nation's largest manufacturing plants - those that consume at least 1 TBtu of energy annually. The 2006 Save Energy Now assessments focused primarily on assessments of steam and process heating systems, which account for an estimated 74% of all natural gas use by U.S. manufacturing plants. Because of the success of the Save Energy Now assessments conducted in 2006 and 2007, the program was expanded and enhanced in two major ways in 2008: (1) a new goal was set to perform at least 260 assessments; and (2) the assessment focus was expanded to include pumping, compressed air, and fan systems in addition to steam and process heating. DOE ITP also has developed software tools to assess energy efficiency improvement opportunities in pumping, compressed air, and fan systems. The Save Energy Now assessments integrate a strong training component designed to teach industrial plant personnel how to use DOE's opportunity assessment software tools. This approach has the advantages of promoting strong buy-in of plant personnel for the assessment and its outcomes and preparing them better to independently replicate the assessment process at the company's other facilities. Another important element of the Save Energy Now assessment process is the follow-up process used to identify how many of the recommended savings opportunities from individual assessments have been implemented in the industrial plants. Plant personnel involved with the Save Energy Now assessments are contacted 6 months, 12 months, and 24 months after individual assessments are completed to determine implementation results. A total of 260 Save Energy Now assessments were successfully completed in calendar year 2008. This means that a total of 718 assessments were completed in 2006, 2007, and 2008. As of July 2009, we have received a total of 239 summary reports from the ESAs that were conducted in year 2008. Hence, at the time that this report was prepared, 680 final assessment reports were completed (200 from year 2006, 241 from year 2007, and 239 from year 2008). The total identified potential cost savings from these 680 assessments is $1.1 billion per year, including natural gas savings of about 98 TBtu per year. These results, if fully implemented, could reduce CO{sub 2} emissions by about 8.9 million metric tons annually. When this report was prepared, data on implementation of recommended energy and cost savings measures from 488 Save Energy Now assessments were available. For these 488 plants, measures saving a total of $147 million per year have been implemented, measures that will save $169 million per year are in the process of being implemented, and plants are planning implementation of measures that will save another $239 million per year. The implemented recommendations are already achieving total CO{sub 2} reductions of about 1.8 million metric tons per year. This report provides a summary of the key results for the Save Energy Now assessments completed in 2008; details of the 6-month, 12-month, and 24-month implementation results obtained to date; and an evaluation of these implementation results. This report also summarizes key accomplishments, findings, and lessons learned from all the Save Energy No

  1. EIS-0463: Notice of Public Meeting Location Change | Department...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Location Change EIS-0463: Notice of Public Meeting Location Change Presidential Permit Application for Northern Pass Transmission, New Hampshire On September 6, 2013, DOE...

  2. Optimization Online - p-facility Huff location problem on networks

    E-Print Network [OSTI]

    Rafael Blanquero

    2014-10-30T23:59:59.000Z

    Oct 30, 2014 ... Abstract: The p-facility Huff location problem aims at locating facilities on a competitive environment so as to maximize the market share.

  3. Incorporation of Detailed Chemical Mechanisms in Reactive Flow Simulations Using Element-Flux Analysis

    E-Print Network [OSTI]

    Androulakis, Ioannis (Yannis)

    ignition (HCCI) combustion with detailed chemistry by using the proposed on-the-fly reduction scheme detailed characterizations of in-cylinder behaviors in stratified HCCI engines by incorporating detailed was proposed for HCCI engines in which homogeneous charge was used. However, although termed "homogeneous

  4. Pattern Alteration: Location of Bust Fullness

    E-Print Network [OSTI]

    2006-08-04T23:59:59.000Z

    ). Figure 1. Bodice with Darts Darts should point toward the fullest part of the bust, ending ? to 1 ? inches (1 to 4 cm) from its tip. This depends on the garment style, your fi gure and personal preference. The Personal Measurement Chart (line 6) can... help you deter- mine the position of your bust point on the pattern. If your measurement and the pattern bust point location differ, you need an alteration. 1. To fi nd the bust point on a basic pattern, extend the center lines of the darts until...

  5. Location of laccase in ordered mesoporous materials

    SciTech Connect (OSTI)

    Mayoral, Álvaro [Laboratorio de Microscopias Avanzadas, Instituto de Nanociencia de Aragon, Universidad de Zaragoza, Edificio I - D, Mariano Esquillor, 50018 Zaragoza (Spain); Gascón, Victoria; Blanco, Rosa M.; Márquez-Álvarez, Carlos; Díaz, Isabel, E-mail: idiaz@icp.csic.es [Instituto de Catálisis y Petroleoquímica, CSIC, c/Marie Curie 2, 28049 Madrid (Spain)

    2014-11-01T23:59:59.000Z

    The functionalization with amine groups was developed on the SBA-15, and its effect in the laccase immobilization was compared with that of a Periodic Mesoporous Aminosilica. A method to encapsulate the laccase in situ has now been developed. In this work, spherical aberration (C{sub s}) corrected scanning transmission electron microscopy combined with high angle annular dark field detector and electron energy loss spectroscopy were applied to identify the exact location of the enzyme in the matrix formed by the ordered mesoporous solids.

  6. GE Global Research Locations | GE Global Research

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItem NotEnergy,ARMFormsGasReleaseSpeechesHall ATours,Dioxide and MethaneLocations GE

  7. Our Locations | National Nuclear Security Administration

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative1 First Use of Energy for All Purposes (Fuel and Nonfuel), 2002; Level: National5Sales for4,645 3,625 1,006 492 742EnergyOnItemResearch > TheNuclear Astrophysics One ofSpeedingthisOur HistoryHistoryLocations |

  8. Modelling cycle to cycle variations in an SI engine with detailed chemical kinetics

    SciTech Connect (OSTI)

    Etheridge, Jonathan; Mosbach, Sebastian; Kraft, Markus [Department of Chemical Engineering and Biotechnology, University of Cambridge (United Kingdom); Wu, Hao; Collings, Nick [Department of Engineering, University of Cambridge (United Kingdom)

    2011-01-15T23:59:59.000Z

    This paper presents experimental results and a new computational model that investigate cycle to cycle variations (CCV) in a spark ignition (SI) engine. An established stochastic reactor model (SRM) previously used to examine homogeneous charge compression ignition (HCCI) combustion has been extended by spark initiation, flame propagation and flame termination sub-models in order to simulate combustion in SI engines. The model contains a detailed chemical mechanism but relatively short computation times are achieved. The flame front is assumed to be spherical and centred at the spark location, and a pent roof and piston bowl geometry are accounted for. The model is validated by simulating the pressure profile and emissions from an iso-octane fuelled single cylinder research engine that showed low CCV. The effects of key parameters are investigated. Experimental results that show cycle to cycle fluctuations in a four-cylinder naturally aspirated gasoline fuelled SI engine are presented. The model is then coupled with GT-Power, a one-dimensional engine simulation tool, which is used to simulate the breathing events during a multi-cycle simulation. This allows an investigation of the cyclic fluctuations in peak pressure. The source and magnitude of nitric oxide (NO) emissions produced by different cycles are then investigated. It was found that faster burning cycles result in increased NO emissions compared with cycles that have a slower rate of combustion and that more is produced in the early stages of combustion compared with later in the cycle. The majority of NO was produced via the thermal mechanism just after combustion begins. (author)

  9. Location-Tracking Applications ecent technological advances in wireless loca-

    E-Print Network [OSTI]

    Gruteser, Marco

    areas they have visited. #12;Location-Tracking Applications broker as part of their service contract

  10. Locating a Recycling Center: The General Density Case Jannett Highfill

    E-Print Network [OSTI]

    Mou, Libin

    Locating a Recycling Center: The General Density Case Jannett Highfill Department of Economics) 677-3374. #12;2 Locating a Recycling Center: The General Density Case Abstract: The present paper considers a municipality that has a landfill (fixed in location) and plans to optimally locate a "recycling

  11. Locating hardware faults in a parallel computer

    DOE Patents [OSTI]

    Archer, Charles J.; Megerian, Mark G.; Ratterman, Joseph D.; Smith, Brian E.

    2010-04-13T23:59:59.000Z

    Locating hardware faults in a parallel computer, including defining within a tree network of the parallel computer two or more sets of non-overlapping test levels of compute nodes of the network that together include all the data communications links of the network, each non-overlapping test level comprising two or more adjacent tiers of the tree; defining test cells within each non-overlapping test level, each test cell comprising a subtree of the tree including a subtree root compute node and all descendant compute nodes of the subtree root compute node within a non-overlapping test level; performing, separately on each set of non-overlapping test levels, an uplink test on all test cells in a set of non-overlapping test levels; and performing, separately from the uplink tests and separately on each set of non-overlapping test levels, a downlink test on all test cells in a set of non-overlapping test levels.

  12. Location Independent Professional Project: A Pilot Study

    SciTech Connect (OSTI)

    Hudson, J.A.; Long, J.P.; Miller, M.M.

    1999-02-01T23:59:59.000Z

    This pilot study project explored the problem of providing access to the nomadic worker who desires to connect a computer through network access points at a number of different locations within the SNL/NM campus as well as outside the campus. The design and prototype development gathered knowledge that may allow a design to be developed that could be extended to a larger number of SNL/NM network drop boxes. The focus was to provide a capability for a worker to access the SNL IRN from a network drop box (e.g. in a conference room) as easily as when accessing the computer network from the office normally used by the worker. Additional study was done on new methods to authenticate the off campus worker, and protect and control access to data.

  13. MobiEyes: A Distributed Location Monitoring Service Using Moving Location Queries

    E-Print Network [OSTI]

    Liu, Ling

    , distributed algorithms, mobile data management. Ç 1 INTRODUCTION WITH the growing availability of mobile-sensitive resource management. The former uses location data to tailor the information delivered to the mobile users traffic and weather. Examples include systems for fleet manage- ment, mobile workforce management

  14. Fault Locating, Prediction and Protection (FLPPS)

    SciTech Connect (OSTI)

    Yinger, Robert, J.; Venkata, S., S.; Centeno, Virgilio

    2010-09-30T23:59:59.000Z

    One of the main objectives of this DOE-sponsored project was to reduce customer outage time. Fault location, prediction, and protection are the most important aspects of fault management for the reduction of outage time. In the past most of the research and development on power system faults in these areas has focused on transmission systems, and it is not until recently with deregulation and competition that research on power system faults has begun to focus on the unique aspects of distribution systems. This project was planned with three Phases, approximately one year per phase. The first phase of the project involved an assessment of the state-of-the-art in fault location, prediction, and detection as well as the design, lab testing, and field installation of the advanced protection system on the SCE Circuit of the Future located north of San Bernardino, CA. The new feeder automation scheme, with vacuum fault interrupters, will limit the number of customers affected by the fault. Depending on the fault location, the substation breaker might not even trip. Through the use of fast communications (fiber) the fault locations can be determined and the proper fault interrupting switches opened automatically. With knowledge of circuit loadings at the time of the fault, ties to other circuits can be closed automatically to restore all customers except the faulted section. This new automation scheme limits outage time and increases reliability for customers. The second phase of the project involved the selection, modeling, testing and installation of a fault current limiter on the Circuit of the Future. While this project did not pay for the installation and testing of the fault current limiter, it did perform the evaluation of the fault current limiter and its impacts on the protection system of the Circuit of the Future. After investigation of several fault current limiters, the Zenergy superconducting, saturable core fault current limiter was selected for installation. Because of some testing problems with the Zenergy fault current limiter, installation was delayed until early 2009 with it being put into operation on March 6, 2009. A malfunction of the FCL controller caused the DC power supply to the superconducting magnet to be turned off. This inserted the FCL impedance into the circuit while it was in normal operation causing a voltage resonance condition. While these voltages never reached a point where damage would occur on customer equipment, steps were taken to insure this would not happen again. The FCL was reenergized with load on December 18, 2009. A fault was experienced on the circuit with the FCL in operation on January 14, 2010. The FCL operated properly and reduced the fault current by about 8%, what was expected from tests and modeling. As of the end of the project, the FCL was still in operation on the circuit. The third phase of the project involved the exploration of several advanced protection ideas that might be at a state where they could be applied to the Circuit of the Future and elsewhere in the SCE electrical system. Based on the work done as part of the literature review and survey, as well as a number of internal meetings with engineering staff at SCE, a number of ideas were compiled. These ideas were then evaluated for applicability and ability to be applied on the Circuit of the Future in the time remaining for the project. Some of these basic ideas were implemented on the circuit including measurement of power quality before and after the FCL. It was also decided that we would take what was learned as part of the Circuit of the Future work and extend it to the next generation circuit protection for SCE. Also at this time, SCE put in a proposal to the DOE for the Irvine Smart Grid Demonstration using ARRA funding. SCE was successful in obtaining funding for this proposal, so it was felt that exploration of new protection schemes for this Irvine Smart Grid Demonstration would be a good use of the project resources. With this in mind, a protection system that uses fault interrupting switches, hi

  15. Evaluation of the role of location and distance in recruitment in respondent-driven sampling

    E-Print Network [OSTI]

    McCreesh, Nicky; Johnston, Lisa G; Copas, Andrew; Sonnenberg, Pam; Seeley, Janet; Hayes, Richard J; Frost, Simon DW; White, Richard G

    2011-10-18T23:59:59.000Z

    that little or no recruitment occurred in cer- tain parts of the target study areas [7-9]. Despite this, to our knowledge no other RDS studies have looked in detail at how the locations of recruits’ residencies affected recruitment, perhaps due... potentially reduce this problem. Our study was carried out in a rural area where the majority of people work as farmers. This is in contrast to many RDS studies which are carried out in towns or cities. In these settings, travel times using available transport...

  16. River Corridor Cleanup Contract Fiscal Year 2006 Detailed Work Plan: DWP Summary, Volume 1

    SciTech Connect (OSTI)

    Project Integration

    2005-09-26T23:59:59.000Z

    This detailed work plan provides the scope, cost, and schedule for the Fiscal Year 2006 activities required to support River Corridor cleanup objectives within the directed guidance.

  17. Webinar: Guidance for Filling Out a Detailed H2A Production Case Study

    Broader source: Energy.gov [DOE]

    Video recording and text version of the webinar titled, Guidance for Filling Out a Detailed H2A Production Case Study, originally presented on July 9, 2013.

  18. Estimating the Energy, Demand and Cost Savings from a Geothermal Heat Pump ESPC Project at Fort Polk, LA Through Utility Bill Analysis.

    SciTech Connect (OSTI)

    Shonder, John A [ORNL; Hughes, Patrick [ORNL

    2006-01-01T23:59:59.000Z

    Energy savings performance contracts (ESPCs) are a method of financing energy conservation projects using the energy cost savings generated by the conservation measures themselves. Ideally, reduced energy costs are visible as reduced utility bills, but in fact this is not always the case. On large military bases, for example, a single electric meter typically covers hundreds of individual buildings. Savings from an ESPC involving only a small number of these buildings will have little effect on the overall utility bill. In fact, changes in mission, occupancy, and energy prices could cause substantial increases in utility bills. For this reason, other, more practical, methods have been developed to measure and verify savings in ESPC projects. Nevertheless, increasing utility bills--when ESPCs are expected to be reducing them--are problematic and can lead some observers to question whether savings are actually being achieved. In this paper, the authors use utility bill analysis to determine energy, demand, and cost savings from an ESPC project that installed geothermal heat pumps in the family housing areas of the military base at Fort Polk, Louisiana. The savings estimates for the first year after the retrofits were found to be in substantial agreement with previous estimates that were based on submetered data. However, the utility bills also show that electrical use tended to increase as time went on. Since other data show that the energy use in family housing has remained about the same over the period, the authors conclude that the savings from the ESPC have persisted, and increases in electrical use must be due to loads unassociated with family housing. This shows that under certain circumstances, and with the proper analysis, utility bills can be used to estimate savings from ESPC projects. However, these circumstances are rare and over time the comparison may be invalidated by increases in energy use in areas unaffected by the ESPC.

  19. The role of the cant and lateral position of the steering wheel in the orientation of drivers to the location of the automotive pedals

    E-Print Network [OSTI]

    Sherrod, M. G

    1989-01-01T23:59:59.000Z

    examined the effects of three steering wheel cants and three steering wheel lateral positions on drivers' preferred automotive foot pedal locations and separation distances. The dependent variables were the preferred vertical and horizontal positions... in orienting the driver to the locations of the pedals and should be part of any design recommendations detailing the relationship between the driver and the foot pedals. ACKNOWLEDGEMENTS I would like to thank the chairman of my Advisory Committee, Dr...

  20. Homodyne impulse radar hidden object locator

    DOE Patents [OSTI]

    McEwan, T.E.

    1996-04-30T23:59:59.000Z

    An electromagnetic detector is designed to locate an object hidden behind a separator or a cavity within a solid object. The detector includes a PRF generator for generating 2 MHz pulses, a homodyne oscillator for generating a 2 kHz square wave, and for modulating the pulses from the PRF generator. A transmit antenna transmits the modulated pulses through the separator, and a receive antenna receives the signals reflected off the object. The receiver path of the detector includes a sample and hold circuit, an AC coupled amplifier which filters out DC bias level shifts in the sample and hold circuit, and a rectifier circuit connected to the homodyne oscillator and to the AC coupled amplifier, for synchronously rectifying the modulated pulses transmitted over the transmit antenna. The homodyne oscillator modulates the signal from the PRF generator with a continuous wave (CW) signal, and the AC coupled amplifier operates with a passband centered on that CW signal. The present detector can be used in several applications, including the detection of metallic and non-metallic objects, such as pipes, studs, joists, nails, rebars, conduits and electrical wiring, behind wood wall, ceiling, plywood, particle board, dense hardwood, masonry and cement structure. The detector is portable, light weight, simple to use, inexpensive, and has a low power emission which facilitates the compliance with Part 15 of the FCC rules. 15 figs.

  1. Homodyne impulse radar hidden object locator

    DOE Patents [OSTI]

    McEwan, Thomas E. (Livermore, CA)

    1996-01-01T23:59:59.000Z

    An electromagnetic detector is designed to locate an object hidden behind a separator or a cavity within a solid object. The detector includes a PRF generator for generating 2 MHz pulses, a homodyne oscillator for generating a 2 kHz square wave, and for modulating the pulses from the PRF generator. A transmit antenna transmits the modulated pulses through the separator, and a receive antenna receives the signals reflected off the object. The receiver path of the detector includes a sample and hold circuit, an AC coupled amplifier which filters out DC bias level shifts in the sample and hold circuit, and a rectifier circuit connected to the homodyne oscillator and to the AC coupled amplifier, for synchronously rectifying the modulated pulses transmitted over the transmit antenna. The homodyne oscillator modulates the signal from the PRF generator with a continuous wave (CW) signal, and the AC coupled amplifier operates with a passband centered on that CW signal. The present detector can be used in several applications, including the detection of metallic and non-metallic objects, such as pipes, studs, joists, nails, rebars, conduits and electrical wiring, behind wood wall, ceiling, plywood, particle board, dense hardwood, masonry and cement structure. The detector is portable, light weight, simple to use, inexpensive, and has a low power emission which facilitates the compliance with Part 15 of the FCC rules.

  2. TAGGING, TRACKING AND LOCATING WITHOUT GPS

    SciTech Connect (OSTI)

    Cordaro, J.; Coleman, T.; Shull, D.

    2012-07-08T23:59:59.000Z

    The Savannah River National Laboratory (SRNL) was requested to lead a Law Enforcement Working Group that was formed to collaborate on common operational needs. All agencies represented on the working group ranked their need to tag, track, and locate a witting or unwitting target as their highest priority. Specifically, they were looking for technologies more robust than Global Positioning Satellite (GPS), could communicate back to the owner, and worked where normal cell phone communications did not work or were unreliable. SRNL brought together multiple technologies in a demonstration that was held in in various Alaska venues, including metropolitan, wilderness, and at-sea that met the working group's requirements. Using prototypical technologies from Boeing, On Ramp, and Fortress, SRNL was able to demonstrate the ability to track personnel and material in all scenarios including indoors, in heavily wooden areas, canyons, and in parking garages. In all cases GPS signals were too weak to measure. Bi-directional communication was achieved in areas that Wi-Fi, cell towers, or traditional radios would not perform. The results of the exercise will be presented. These technologies are considered ideal for tracking high value material such has nuclear material with a platform that allows seamless tracking anywhere in the world, indoors or outdoors.

  3. Etherthreads : an infrastructure for location-based messages

    E-Print Network [OSTI]

    Lassey, Bradford, 1980-

    2004-01-01T23:59:59.000Z

    This thesis proposes an infrastructure for location-based services for Bluetooth enabled cellular phones. Specifically, it explores the use of this architecture in a location-based messaging application. A user can send ...

  4. Provable and practical location privacy for vehicular and mobile systems

    E-Print Network [OSTI]

    Popa, Raluca Ada

    2010-01-01T23:59:59.000Z

    In recent years, there has been a rapid evolution of location-based vehicular and mobile services (e.g., electronic tolling, congestion pricing, traffic statistics, insurance pricing, location-based social applications), ...

  5. A unified Bayesian framework for relative microseismic location

    E-Print Network [OSTI]

    Poliannikov, Oleg V.

    We study the problem of determining an unknown microseismic event location relative to previously located events using a single monitoring array in a monitoring well. We show that using the available information about the ...

  6. A unified Bayesian framework for relative microseismic location

    E-Print Network [OSTI]

    Poliannikov, Oleg V.

    2013-01-01T23:59:59.000Z

    We study the problem of determining an unknown microseismic event location relative to previously located events using a single monitoring array in a monitoring well. We show that using the available information about the ...

  7. Holdout transshipment policy in two-location inventory systems 

    E-Print Network [OSTI]

    Zhang, Jiaqi

    2009-01-01T23:59:59.000Z

    In two-location inventory systems, unidirectional transshipment policies are considered when an item is not routinely stocked at a location in the system. Unlike the past research in this area which has concentrated on ...

  8. Policy-aware sender anonymity in Location-based services

    E-Print Network [OSTI]

    Vyas, Avinash

    2011-01-01T23:59:59.000Z

    LBS Server Location Server CSP Sender Figure 1.1: LBS ModelService Provider, denoted as CSP, the Location Server,is either the MPC in the CSP’s network or an Over-The-Top (

  9. Locating a semi-obnoxious facility with repelling polygonal regions

    E-Print Network [OSTI]

    2007-04-30T23:59:59.000Z

    Apr 30, 2007 ... Page 1 ... For the last years, the location of semi-desirable facilities has been a widely studied topic by the researchers in location theory (see [1 ...

  10. University of California, Irvine Updated 3.5.13 Help keep batteries and printer cartridges out of the trash by recycling your used batteries at one of the locations

    E-Print Network [OSTI]

    Rose, Michael R.

    of the trash by recycling your used batteries at one of the locations listed below. Used batteries & cartridgesUniversity of California, Irvine Updated 3.5.13 Help keep batteries and printer cartridges out are collected weekly by Facilities Management Recycling Team. Building Location Detail Academy 101 1st Floor 1

  11. Arkansas Regional Middle School Science Bowl | U.S. DOE Office...

    Office of Science (SC) Website

    teams will be approved to participate. Competition Location University of Arkansas Fort Smith Math and Science Building Fort Smith, Arkansas 72903 Regional Contact Information...

  12. Arkansas Regional High Science Bowl | U.S. DOE Office of Science...

    Office of Science (SC) Website

    that you can bring to the competition. Competition Location University of Arkansas-Fort Smith Math-Science (MS) Building 5210 Grand Avenue Fort Smith, Arkansas 72913 Regional...

  13. Risks of using AP locations discovered through war driving

    E-Print Network [OSTI]

    Kotz, David

    Risks of using AP locations discovered through war driving Minkyong Kim, Jeffrey J. Fielding the actual locations are often unavailable, they use estimated locations from war driving estimated through war driving. War driving is the process of collecting Wi-Fi beacons by driving or walking

  14. Accurate Eye Center Location through Invariant Isocentric Patterns

    E-Print Network [OSTI]

    Gevers, Theo

    1 Accurate Eye Center Location through Invariant Isocentric Patterns Roberto Valenti, Student Member, IEEE, and Theo Gevers, Member, IEEE, Abstract--Locating the center of the eyes allows for valuable information to be captured and used in a wide range of applications. Accurate eye center location

  15. Topological Reconstruction of Complex 3D Buildings and Automatic Extraction of Levels of Detail

    E-Print Network [OSTI]

    Boyer, Edmond

    and outdoor topology of a detailed 3D building model from its geometry and to extract different levelsTopological Reconstruction of Complex 3D Buildings and Automatic Extraction of Levels of Detail A is needed for most of the applications using 3D building models after the architects design it. While

  16. EconoGrid: A detailed Simulation Model of a Standards-based Grid Compute Economy

    E-Print Network [OSTI]

    EconoGrid: A detailed Simulation Model of a Standards-based Grid Compute Economy EconoGrid is a detailed simulation model, implemented in SLX1 , of a grid compute economy that implements selected of users. In a grid compute economy, computing resources are sold to users in a market where price

  17. Cyclic Testing of Concrete-Filled Circular Steel Bridge Piers having Encased Fixed-Based Detail

    E-Print Network [OSTI]

    Bruneau, Michel

    Cyclic Testing of Concrete-Filled Circular Steel Bridge Piers having Encased Fixed-Based Detail elements during earthquakes, this paper reports on cyclic inelastic tests executed to determine the maximum strength and ductility of four concrete-filled circular steel piers joined to a foundation detail proposed

  18. Dendrodendritic Inhibition and Simulated Odor Responses in a Detailed Olfactory Bulb Network Model

    E-Print Network [OSTI]

    Feng, Jianfeng

    Dendrodendritic Inhibition and Simulated Odor Responses in a Detailed Olfactory Bulb Network Model responses in a detailed olfac- tory bulb network model. J Neurophysiol 90: 1921­1935, 2003. First published May 7, 2003; 10.1152/jn.00623.2002. In the olfactory bulb, both the spatial distribution

  19. Radiation damage in the LHCb Vertex Locator

    E-Print Network [OSTI]

    A. Affolder; K. Akiba; M. Alexander; S. Ali; M. Artuso; J. Benton; M. van Beuzekom; P. M. Bj\\ornstad; G. Bogdanova; S. Borghi; T. J. V. Bowcock; H. Brown; J. Buytaert; G. Casse; P. Collins; S. De Capua; D. Dossett; L. Eklund; C. Farinelli; J. Garofoli; M. Gersabeck; T. Gershon; H. Gordon; J. Harrison; V. Heijne; K. Hennessy; D. Hutchcroft; E. Jans; M. John; T. Ketel; G. Lafferty; T. Latham; A. Leflat; M. Liles; D. Moran; I. Mous; A. Oblakowska-Mucha; C. Parkes; G. D. Patel; S. Redford; M. M. Reid; K. Rinnert; E. Rodrigues; M. Schiller; T. Szumlak; C. Thomas; J. Velthuis; V. Volkov; A. D. Webber; M. Whitehead; E. Zverev

    2013-02-21T23:59:59.000Z

    The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately $\\rm{45 \\times 10^{12}\\,1\\,MeV}$ neutron equivalent ($\\rm{1\\,MeV\\,n_{eq}}$). At the operational sensor temperature of approximately $-7\\,^{\\circ}\\rm{C}$, the average rate of sensor current increase is $18\\,\\upmu\\rm{A}$ per $\\rm{fb^{-1}}$, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of $E_{g}=1.16\\pm0.03\\pm0.04\\,\\rm{eV}$ obtained. The first observation of n-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around $15 \\times 10 ^{12}$ of $1\\,\\rm{MeV\\,n_{eq}}$. The only n-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately $\\rm{3 \\times 10^{12}\\,1\\,MeV\\,n_{eq}}$, a decrease in the Effective Depletion Voltage (EDV) of around 25\\,V is observed, attributed to oxygen induced removal of boron interstitial sites. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n-on-n type sensors, with rates of $(1.43\\pm 0.16) \\times 10 ^{-12}\\,\\rm{V} / \\, 1 \\, \\rm{MeV\\,n_{eq}}$ and $(1.35\\pm 0.25) \\times 10 ^{-12}\\,\\rm{V} / \\, 1 \\, \\rm{MeV\\,n_{eq}}$ measured for n-on-p and n-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed.

  20. Fort Devens: Cold Climate Market-Rate Townhomes Targeting HERS Index of 40, Harvard, Massachusetts (Fact Sheet), Building America Case Study: Whole-House Solutions for New Homes, Building Technologies Office (BTO)

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed offOCHCO2: FinalOffers3.pdf0-45.pdf Flash2010-45.pdfFlash2011-43andPropertyForPlans FactFort Devens:

  1. Sensitivity of forced air distribution system efficiency to climate, duct location, air leakage and insulation

    E-Print Network [OSTI]

    Walker, Iain

    2001-01-01T23:59:59.000Z

    Location, Air Leakage and Insulation Iain S. Walker Energy4 Duct Insulation, Location and Leakageinsulation

  2. SPIDERS Fort Carson Industry Day

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    20% 25% 30% 35% 40% 45% Info Tech BankingFinance Dams FoodAgriculture Communications Health Care Transportation Nuclear Government Chemical Crit Manufacturing Commercial...

  3. School of Electrical & Computer Engineering -Undergraduate Post Graduate Activities Detail & History

    E-Print Network [OSTI]

    Lipson, Michal

    & Computer Engineering - Undergraduate (continued) 2010 Employment Employer Title City State General Motors2010 School of Electrical & Computer Engineering - Undergraduate Post Graduate Activities Detail Engineering undergraduate students from the Class of 2010. Historical data is provided to allow for comparison

  4. A Detailed Multi-Zone Thermodynamic Simulation For Direct-Injection Diesel Engine Combustion

    E-Print Network [OSTI]

    Xue, Xingyu 1985-

    2012-11-15T23:59:59.000Z

    A detailed multi-zone thermodynamic simulation has been developed for the direct-injection (DI) diesel engine combustion process. For the purpose of predicting heterogeneous type combustion systems, the model explores the formation of pre...

  5. Embedding methods for massing and detail design in computer generated design of skyscrapers

    E-Print Network [OSTI]

    Chen, Shouheng, S.M. Massachusetts Institute of Technology

    2006-01-01T23:59:59.000Z

    This thesis proposes a new digital system to construct the massing and details of skyscrapers. It extracts underlying rules and design conventions from significant projects in contemporary skyscraper design practice. These ...

  6. A brief overview of some historical details of the city of Oak...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    very detailed document was published in 1961 by the Atomic Energy Commission as the city had just completed becoming incorporated in the state of Tennessee. Changes began to be...

  7. Detailed Modeling of HCCI and PCCI combustion and Multi-cylinder...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Modeling of HCCI and PCCI combustion and Multi-cylinder HCCI Engine Control Detailed Modeling of HCCI and PCCI combustion and Multi-cylinder HCCI Engine Control 2003 DEER...

  8. http://www.regulations.gov/#!documentDetail;D=EERE-2014-BT-STD...

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    http:www.regulations.govdocumentDetail;DEERE-2014-BT-STD-0031-0002 EERE-2014-BT-STD-0031-0002 spreadsheet Sheet "Summary Switching" - Before ME1 19421032v.1 http:...

  9. A Detailed Multi-Zone Thermodynamic Simulation For Direct-Injection Diesel Engine Combustion 

    E-Print Network [OSTI]

    Xue, Xingyu 1985-

    2012-11-15T23:59:59.000Z

    A detailed multi-zone thermodynamic simulation has been developed for the direct-injection (DI) diesel engine combustion process. For the purpose of predicting heterogeneous type combustion systems, the model explores the formation of pre...

  10. Environmental Life-cycle Assessment of Passenger Transportation: A Detailed Methodology for Energy,

    E-Print Network [OSTI]

    California at Berkeley, University of

    Environmental Life-cycle Assessment of Passenger Transportation: A Detailed Methodology for Energy and Environmental Engineering Civil Systems Program mchester@cal.berkeley.edu Project Director: Arpad Horvath, Associate Professor University of California, Berkeley Department of Civil and Environmental Engineering

  11. Program Details Investing in your education with the Master of Management -International Accounting and

    E-Print Network [OSTI]

    Business Strategy Consolidated Financial Statements Accounting Systems Control & Auditing CorporateProgram Details Investing in your education with the Master of Management - International Accounting and Finance, will provide you with thorough business knowledge that will serve as a foundation

  12. Clinical Instructor Responsibilities The APTA has detailed voluntary guidelines for clinical instructors. The guidelines

    E-Print Network [OSTI]

    Contractor, Anis

    Clinical Instructor Responsibilities The APTA has detailed voluntary guidelines for clinical instructors. The guidelines are divided into six key areas: · Clinical competence and legal and ethical behavior that meets or exceeds

  13. Fracture mechanics analysis on the resistance of welded details under variable amplitude long life loading 

    E-Print Network [OSTI]

    Zhou, Minjian

    1993-01-01T23:59:59.000Z

    Fracture mechanics approach has been used to analyze the behavior of fatigue resistance of welded details existing in highway steel bridges under variable amplitude long life loading which means most of the stress ranges will be below constant...

  14. Detailed chemical kinetic mechanism for the oxidation of biodiesel fuels blend surrogate

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 Detailed chemical kinetic mechanism for the oxidation of biodiesel fuels blend surrogate of biodiesel fuels in diesel and homogeneous charge compression ignition engines. Keywords: Methyl decanoate; Methyl decenoate; Surrogate; Oxidation; Biodiesel fuels; Kinetic modeling; Engine; Low

  15. Continuous wavelet transform analysis and modal location analysis acoustic emission source location for nuclear piping crack growth monitoring

    SciTech Connect (OSTI)

    Mohd, Shukri [Nondestructive Testing Group, Industrial Technology Division, Malaysian Nuclear Agency, 43000, Bangi, Selangor (Malaysia); Holford, Karen M.; Pullin, Rhys [Cardiff School of Engineering, Cardiff University, Queen's Buildings, The Parade, CARDIFF CF24 3AA (United Kingdom)

    2014-02-12T23:59:59.000Z

    Source location is an important feature of acoustic emission (AE) damage monitoring in nuclear piping. The ability to accurately locate sources can assist in source characterisation and early warning of failure. This paper describe the development of a novelAE source location technique termed 'Wavelet Transform analysis and Modal Location (WTML)' based on Lamb wave theory and time-frequency analysis that can be used for global monitoring of plate like steel structures. Source location was performed on a steel pipe of 1500 mm long and 220 mm outer diameter with nominal thickness of 5 mm under a planar location test setup using H-N sources. The accuracy of the new technique was compared with other AE source location methods such as the time of arrival (TOA) techniqueand DeltaTlocation. Theresults of the study show that the WTML method produces more accurate location resultscompared with TOA and triple point filtering location methods. The accuracy of the WTML approach is comparable with the deltaT location method but requires no initial acoustic calibration of the structure.

  16. Automated detection and location of indications in eddy current signals

    DOE Patents [OSTI]

    Brudnoy, David M. (Albany, NY); Oppenlander, Jane E. (Burnt Hills, NY); Levy, Arthur J. (Schenectady, NY)

    2000-01-01T23:59:59.000Z

    A computer implemented information extraction process that locates and identifies eddy current signal features in digital point-ordered signals, signals representing data from inspection of test materials, by enhancing the signal features relative to signal noise, detecting features of the signals, verifying the location of the signal features that can be known in advance, and outputting information about the identity and location of all detected signal features.

  17. Locations of Smart Grid Demonstration and Large-Scale Energy...

    Broader source: Energy.gov (indexed) [DOE]

    the location of all projects created with funding from the Smart Grid Demonstration and Energy Storage Project, funded through the American Recovery and Reinvestment Act....

  18. Optimization Online - An MILP approach to Multi-location, Multi ...

    E-Print Network [OSTI]

    Christina N Burt

    2014-11-30T23:59:59.000Z

    Nov 30, 2014 ... An MILP approach to Multi-location, Multi-Period Equipment Selection for Surface Mining with Case Studies. Christina N Burt(cnburt ***at*** ...

  19. Located in historic Los Alamos, New Mexico against the backdrop...

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Located in historic Los Alamos, New Mexico against the backdrop of the lush Jemez Mountains, Los Alamos National Laboratory (LANL) offers its education program participants...

  20. NMOCD - Form G-102 - Geothermal Resources Well Location and Acreage...

    Open Energy Info (EERE)

    Well Location and Acreage Dedication Plat Author State of New Mexico Energy and Minerals Department Published New Mexico Oil Conservation Division, 1978 DOI Not Provided...

  1. Attack-Resistant Location Estimation in Sensor (Revised August 2005)

    E-Print Network [OSTI]

    Ning, Peng

    role in many sensor network applications. Not only do applications such as environment monitoring and target tracking require sensors' location information to fulfill their tasks, but several fundamental

  2. acoustic location system: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    ON POWER SYSTEMS, VOL. 29, NO. 1, JANUARY 2014 203 Distribution Locational Marginal Pricing for Optimal Power Transmission, Distribution and Plants Websites Summary:...

  3. anatomic subsite location: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    services (e.g., electronic tolling, congestion pricing, traffic statistics, insurance pricing, location-based social applications), ... Popa, Raluca Ada 2010-01-01 First Page...

  4. agency dtra location: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    flows or spillovers between multinational enterprises (MNEs the diversity of locational environments. The localization of knowledge sources depends on MNE group of...

  5. Research Site Locations for Current and Former EERE Postdoctoral...

    Broader source: Energy.gov (indexed) [DOE]

    Research Site Locations for Current and Former EERE Postdoctoral Awards, from the U.S. Department of Energy's Office of Energy Efficiency and Renewable Energy. eeremap2015.pdf...

  6. The Value of Flexibility in Robust Location-Transportation Problem

    E-Print Network [OSTI]

    Amir Ardestani-Jaafari

    2014-11-25T23:59:59.000Z

    Nov 25, 2014 ... Abstract: Facility location decisions play a critical role in transportation planning. In fact, it has recently become essential to study how such ...

  7. Title 33 CFR 115 Bridge Locations and Clearances: Administrative...

    Open Energy Info (EERE)

    OpenEI Reference LibraryAdd to library Legal Document- Federal RegulationFederal Regulation: Title 33 CFR 115 Bridge Locations and Clearances: Administrative ProceduresLegal...

  8. Identification of High Collision Concentration Locations Under Wet Weather Conditions

    E-Print Network [OSTI]

    Hwang, Taesung; Chung, Koohong; Ragland, David; Chan, Chin-Yao

    2008-01-01T23:59:59.000Z

    conducted under wet weather conditions. Observations fromLeahy, M. , and Suggett, J. Weather as a Chronic Hazard forLocations Under Wet Weather Conditions Taesung Hwang,

  9. p-facility Huff location problem on networks ?

    E-Print Network [OSTI]

    2014-10-30T23:59:59.000Z

    ing field, in problems such as location of petrol stations, shopping centers or restaurants. [14, 20, 22]. Network optimization models [5] are widely used in practice ...

  10. Colorado CRS 29-20-108, Location, Construction, or Improvement...

    Open Energy Info (EERE)

    Location, Construction, or Improvement of Major Electrical or Natural Gas Facilities Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document-...

  11. Condensing Heating and Water Heating Equipment Workshop Location...

    Energy Savers [EERE]

    Condensing Heating and Water Heating Equipment Workshop Location: Washington Gas Light Appliance Training Facility 6801 Industrial Road Springfield, VA Date: October 9, 2014 Time:...

  12. Blind Channel Identification for the Emitter Location Problem

    E-Print Network [OSTI]

    Fowler, Mark

    a thesis entitled "Blind Channel Identification for the Emitter Location Problem: A Least Square ApproachBlind Channel Identification for the Emitter Location Problem: A Least Square Approach BY Cheung C. Chau B.S.E.E., Binghamton University, 2000 Thesis Submitted in Partial Fulfillment of the Requirements

  13. Model-based Lifecycle Optimization of Well Locations

    E-Print Network [OSTI]

    Van den Hof, Paul

    Model-based Lifecycle Optimization of Well Locations and Production Settings in Petroleum Reservoirs #12;#12;MODEL-BASED LIFECYCLE OPTIMIZATION OF WELL LOCATIONS AND PRODUCTION SETTINGS IN PETROLEUM System Approach Petroleum Production" (ISAPP) programme. The knowledge center is a long-term co

  14. Benefits of Location-Based Access Control: A Literature Study

    E-Print Network [OSTI]

    Wieringa, Roel

    Benefits of Location-Based Access Control: A Literature Study Andr´e van Cleeff, Wolter Pieters.pieters, r.j.wieringa}@utwente.nl Abstract--Location-based access control (LBAC) has been suggested-based, physical and logical access control, (ii) improving the transparency of LBAC decision making, and (iii

  15. Quartz resonators thermal modelization using located constants networks

    E-Print Network [OSTI]

    Boyer, Edmond

    of quartz resonator. The designed model is tested by comparison of the experimental frequency versus235 Quartz resonators thermal modelization using located constants networks S. Galliou and J. P modelization of quartz resonators is first presented ; next, the method consisting on establishing a located

  16. Detecting and Locating Radioactive Signals with Wireless Sensor Networks

    E-Print Network [OSTI]

    Zhang, Tonglin

    Detecting and Locating Radioactive Signals with Wireless Sensor Networks Tonglin Zhang Department-765-4940558 AbstractMethods of detecting and locating nuclear radioac- tive targets via wireless sensor networks (WSN model, radia- tion and radioactive isotopes, wireless sensor network. I. INTRODUCTION Currently, using

  17. A MODELING APPROACH FOR LOCATING LOGISTICS PLATFORMS FOR FAST PARCEL

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    1 29 A MODELING APPROACH FOR LOCATING LOGISTICS PLATFORMS FOR FAST PARCEL DELIVERY IN URBAN AREAS for optimizing, in a sustainable way (i.e. economical, eco-friendly and societal), the location of logistics has a logistics platform right in its centre (ARENC: 41362 m2 of warehouses and offices

  18. Facility Location with Hierarchical Facility Costs Zoya Svitkina #

    E-Print Network [OSTI]

    Tardos, Ă?va

    Facility Location with Hierarchical Facility Costs Zoya Svitkina # â?? Eva Tardos + Abstract We consider the facility location problem with hierarchi­ cal facility costs, and give a (4 installation costs. Shmoys, Swamy and Levi [13] gave an approxi­ mation algorithm for a two­level version

  19. Comparison of Different Methods for Next Location Prediction

    E-Print Network [OSTI]

    Ungerer, Theo

    Comparison of Different Methods for Next Location Prediction Jan Petzold, Faruk Bagci, Wolfgang prediction anticipates a person's movement based on the history of previous sojourns. It is useful location prediction methods: dynamic Bayesian network, multi-layer perceptron, Elman net, Markov predictor

  20. Location of Mobile Terminals using Time Measurements and Survey Points

    E-Print Network [OSTI]

    Plataniotis, Konstantinos N.

    Location of Mobile Terminals using Time Measurements and Survey Points M. McGuire ,K.N. Plataniotis is the Time Difference of Arrival (TDoA)method where the location of the mobile terminal is estimated using research communityon technologiesthat can estimatethe loca- tion of mobile terminals. Mobile terminal

  1. Models for Offender Target Location Selection with Explicit Dependency Structures

    E-Print Network [OSTI]

    O'Leary, Michael

    Models for Offender Target Location Selection with Explicit Dependency Structures Mike O'Leary April 30 - May 1, 2012 O'Leary & Tucker (Towson University) Target Location Selection QMDNS 2012 1 / 54 in this study We thank Phil Canter from the Baltimore County Police Department for his assistance. O'Leary

  2. Anywhere But Here: An Introduction to State Control of Hazardous Waste Facility Location

    E-Print Network [OSTI]

    Tarlock, Dan A.

    1981-01-01T23:59:59.000Z

    State Control Of Hazardous- Waste Facility Location A. Danautonomy over the location of hazardous-waste managementa hazardous-waste facility-siting process is the location of

  3. Residential mobility and location choice: a nested logit model with sampling of alternatives

    E-Print Network [OSTI]

    Lee, Brian H.; Waddell, Paul

    2010-01-01T23:59:59.000Z

    Waddell, P. : Modeling residential location in UrbanSim. In:D. (eds. ) Modelling Residential Location Choice. Springer,based model system and a residential location model. Urban

  4. *Please note: Some details in syllabus are subject to change City University London and Utrecht University

    E-Print Network [OSTI]

    Martin, Ralph R.

    *Please note: Some details in syllabus are subject to change City University London and Utrecht on the course website) In-residence London/Utrecht: 8 July ­ 10 August 2012 Programme requires a total of seven and Utrecht, the Netherlands. This innovative programme provides an ideal opportunity for students to develop

  5. Combining Global and Local Virtual Lights for Detailed Glossy Illumination Tomas Davidovic

    E-Print Network [OSTI]

    Bala, Kavita

    approach Figure 1: Comparison of our approach with Virtual Spherical Lights (VSLs). Left: VSLs fail of these algorithms in design applications. Recently, virtual spherical lights [Hasan et al. 2009] were introducedCombining Global and Local Virtual Lights for Detailed Glossy Illumination Tom´as Davidovic

  6. 2008-01-0333 Detailed Effects of a Diesel Particulate Filter on the Reduction

    E-Print Network [OSTI]

    Wu, Mingshen

    2008-01-0333 Detailed Effects of a Diesel Particulate Filter on the Reduction of Chemical Species of Wisconsin-Madison Copyright © 2008 SAE International ABSTRACT Diesel particulate filters are designed to reduce the mass emissions of diesel particulate matter and have been proven to be effective

  7. POTENTIAL OF THORIUM MOLTEN SALT REACTORS : DETAILED CALCULATIONS AND CONCEPT EVOLUTIONS

    E-Print Network [OSTI]

    Boyer, Edmond

    POTENTIAL OF THORIUM MOLTEN SALT REACTORS : DETAILED CALCULATIONS AND CONCEPT EVOLUTIONS IN VIEW the concept of Thorium Molten Salt Reactor dedicated to future nuclear energy production. The fuel of such reactors being liquid, it can be easily reprocessed to overcome neutronic limits. In the late sixties

  8. Crucial role of detailed function, task, timeline, link and human vulnerability analyses in HRA

    SciTech Connect (OSTI)

    Ryan, T.G.; Haney, L.N.; Ostrom, L.T.

    1992-10-01T23:59:59.000Z

    This paper addresses one major cause for large uncertainties in human reliability analysis (HRA) results, that is, an absence of detailed function, task, timeline, link and human vulnerability analyses. All too often this crucial step in the HRA process is done in a cursory fashion using word of mouth or written procedures which themselves may incompletely or inaccurately represent the human action sequences and human error vulnerabilities being analyzed. The paper examines the potential contributions these detailed analyses can make in achieving quantitative and qualitative HRA results which are: (1) creditable, that is, minimize uncertainty, (2) auditable, that is, systematically linking quantitative results and qualitative information from which the results are derived, (3) capable of supporting root cause analyses on human reliability factors determined to be major contributors to risk, and (4) capable of repeated measures and being combined with similar results from other analyses to examine HRA issues transcending individual systems and facilities. Based on experience analyzing test and commercial nuclear reactors, and medical applications of nuclear technology, an iterative process is suggested for doing detailed function, task, timeline, link and human vulnerability analyses using documentation reviews, open-ended and structured interviews, direct observations, and group techniques. Finally, the paper concludes that detailed analyses done in this manner by knowledgeable human factors practitioners, can contribute significantly to the credibility, auditability, causal factor analysis, and combining goals of the HRA.

  9. On the spherically symmetrical combustion of methyl decanoate droplets and comparisons with detailed numerical modeling

    E-Print Network [OSTI]

    Walter, M.Todd

    .53­0.57 mm and the combustion gas is normal atmospheric pressure air. A detailed numerical simulationOn the spherically symmetrical combustion of methyl decanoate droplets and comparisons Biodiesel Biofuel Microgravity Numerical Droplet combustion a b s t r a c t This study presents

  10. Detailed Analysis of the Microbial Population in Malaysian Spontaneous Cocoa Pulp Fermentations

    E-Print Network [OSTI]

    , lactic acid bacteria (LAB) and acetic acid bacteria (AAB) are the key players of this fermentationDetailed Analysis of the Microbial Population in Malaysian Spontaneous Cocoa Pulp Fermentations), Leuven, Belgium, 3 Barry Callebaut AG, Zurich, Switzerland Abstract The fermentation of cocoa pulp is one

  11. PREDICTION OF DELAM INATION IN WIND TURBINE BLADE STRUCTURAL DETAILS John F. Mandell, Douglas S. Cairns

    E-Print Network [OSTI]

    materials structures such as wind turbine blades. Design methodologies to prevent such failures have static and fatigue loading. INTRODUCTION Composite material structures such as wind turbine blades1 PREDICTION OF DELAM INATION IN WIND TURBINE BLADE STRUCTURAL DETAILS John F. Mandell, Douglas S

  12. Presented at 1999 EWEC Effects of Materials Parameters and Design Details on the Fatigue of

    E-Print Network [OSTI]

    of Composite Materials for Wind Turbine Blades John F. Mandell and Herbert J. Sutherland* Daniel D. SamborskyPresented at 1999 EWEC Effects of Materials Parameters and Design Details on the Fatigue Wind Energy Technology Dept. Dept. of Chemical Engineering Sandia National Laboratories Montana State

  13. Rental Rates & Details Karen Clark Events Coordinator Mildred Lane Kemper Art Museum

    E-Print Network [OSTI]

    Subramanian, Venkat

    Rental Rates & Details Karen Clark · Events Coordinator · Mildred Lane Kemper Art Museum Washington_clark@ wustl.edu kemperartmuseum.wustl.edu Updated 10.08.14 Consider the Mildred Lane Kemper Art Museum for your next event. Designed by the award-winning architect Fumihiko Maki, the Kemper Art Museum

  14. New study details glacier ice loss following ice shelf July 25, 2011

    E-Print Network [OSTI]

    Cambridge, University of

    of several ice shelves in Antarctica led to acceleration of the glaciers that feed into them. CombiningNew study details glacier ice loss following ice shelf collapse July 25, 2011 Contact: Anthony Lane further demonstrates how important ice shelves are to Antarctic glaciers.' Shuman is lead author

  15. Detailed design report for an operational phase panel-closure system

    SciTech Connect (OSTI)

    NONE

    1996-01-11T23:59:59.000Z

    Under contract to Westinghouse Electric Corporation (Westinghouse), Waste Isolation Division (WID), IT Corporation has prepared a detailed design of a panel-closure system for the Waste Isolation Pilot Plant (WIPP). Preparation of this detailed design of an operational-phase closure system is required to support a Resource Conservation and Recovery Act (RCRA) Part B permit application and a non-migration variance petition. This report describes the detailed design for a panel-closure system specific to the WIPP site. The recommended panel-closure system will adequately isolate the waste-emplacement panels for at least 35 years. This report provides detailed design and material engineering specifications for the construction, emplacement, and interface-grouting associated with a panel-closure system at the WIPP repository, which would ensure that an effective panel-closure system is in place for at least 35 years. The panel-closure system provides assurance that the limit for the migration of volatile organic compounds (VOC) will be met at the point of compliance, the WIPP site boundary. This assurance is obtained through the inherent flexibility of the panel-closure system.

  16. Chemical Engineering Journal 113 (2005) 205214 A detailed model of a biofilter for ammonia removal

    E-Print Network [OSTI]

    2005-01-01T23:59:59.000Z

    Chemical Engineering Journal 113 (2005) 205­214 A detailed model of a biofilter for ammonia removal Manresa, Spain b Department of Chemical and Environmental Engineering, University of California, Riverside, 92521 CA, USA c Department of Chemical Engineering, Universitat Aut`onoma de Barcelona, Edifici C, 08193

  17. Impaired Oral Reading in Surface Dyslexia: Detailed Comparison of a Patient and a

    E-Print Network [OSTI]

    Plaut, David C.

    Impaired Oral Reading in Surface Dyslexia: Detailed Comparison of a Patient and a Connectionist connectionist network. ¤ Both MP and the network exhibit the characteristic pattern of surface dyslexia system masters some but not all exception words, and that surface dyslexia arises when this system

  18. Elucidating secondary organic aerosol from diesel and gasoline vehicles through detailed characterization of

    E-Print Network [OSTI]

    Silver, Whendee

    Elucidating secondary organic aerosol from diesel and gasoline vehicles through detailed 19, 2012 (received for review July 22, 2012) Emissions from gasoline and diesel vehicles and diesel vehicles, and find diesel exhaust is seven times more efficient at forming aerosol than gasoline

  19. Chemistry Major, Geology Emphasis See www.chem.utah.edu for details or contact

    E-Print Network [OSTI]

    Simons, Jack

    Chemistry Major, Geology Emphasis See www.chem.utah.edu for details or contact Professor Richard Laboratory for Scientists and Engineers I, II (1, 1) E. Chemistry, Geology Emphasis Core courses, plus: CHEM to Earth Systems (3) GEO 1115 Laboratory for Introduction to Earth Systems (1) GEO 3060 Structural Geology

  20. Texas A&M University A detailed account of how one university

    E-Print Network [OSTI]

    20 percent · Decrease greenhouse gas emissions associated with energy consumption by 30 percentTexas A&M University A detailed account of how one university is improving its energy efficiency and campus environment through effective management and performance contracting usa.siemens.com/tamu #12;One

  1. Program Details Investing in your education with the Master of Management -Logistics and Supply Chain

    E-Print Network [OSTI]

    Program Details Investing in your education with the Master of Management - Logistics and Supply business world. The course based Master of Management - Logistics and Supply Chain Management will prepare you for a leadership position within the Logistics industry in Canada or abroad. You will study

  2. Faculty of Engineering Courses click on a course to view details

    E-Print Network [OSTI]

    Mottram, Nigel

    ENGINEERING MSc/PgDip 37 MARINE TECHNOLOGY MSc/PgDip/PgCert 04 MECHANICAL ENGINEERING, ADVANCED MSc/PgDip 39 URBAN DESIGN MSc/PgDip/PgCert 08 WIND ENERGY SYSTEMS MSc 33 #12;FACULTY OF ENGINEERING 2 back1 Faculty of Engineering Courses click on a course to view details FACULTY OF ENGINEERING COURSE

  3. COMBINED THERMAL MEASUREMENT AND SIMULATION FOR THE DETAILED ANALYSIS OF FOUR OCCUPIED LOW-ENERGY BUILDINGS

    E-Print Network [OSTI]

    Gieseler, Udo D. J.

    COMBINED THERMAL MEASUREMENT AND SIMULATION FOR THE DETAILED ANALYSIS OF FOUR OCCUPIED LOW-ENERGY BUILDINGS U.D.J. Gieseler, F.D. Heidt1 , W. Bier Division of Building Physics and Solar Energy, University energy and temperature measurements of occupied buildings very well. These buildings repre- sent small

  4. Soclety of Petroteum Engineers CT Scan and Neural Network Technology for Construction of Detailed

    E-Print Network [OSTI]

    Patzek, Tadeusz W.

    of Detailed Distribution of Residual Oil Saturation During Waterflooding A. Garg', A.R. Kovscek2, M. Nikravesh reservoirs. Fractured petroleum reservoirs provide over 20 ?ZO of the world oil reserves [1]. Examples of prolific fmctured reservoirs are: the Monterey Shales in California (estimated tens of billions of barrels

  5. Detailed chemical kinetic reaction mechanism for biodiesel components methyl stearate and methyl oleate

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Detailed chemical kinetic reaction mechanism for biodiesel components methyl stearate and methyl are developed for two of the five major components of biodiesel fuel, methyl stearate and methyl oleate renewable sources, can reduce net emissions of greenhouse gases. An important class of biodiesel fuels

  6. Detailed chemical kinetic reaction mechanisms for soy and rapeseed biodiesel fuels

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    Detailed chemical kinetic reaction mechanisms for soy and rapeseed biodiesel fuels C.K. Westbrooka chemical kinetic reaction mechanism is developed for the five major components of soy biodiesel and rapeseed biodiesel fuels. These components, methyl stearate, methyl oleate, methyl linoleate, methyl

  7. JOURNAL PRODUCTION CHECKLIST For detailed instructions, refer to the Student Journal Editors Handbook

    E-Print Network [OSTI]

    Kammen, Daniel M.

    JOURNAL PRODUCTION CHECKLIST For detailed instructions, refer to the Student Journal Editors before agreements are forwarded to authors. Executed agreements are mandatory ­ no journal may by the printer for any additional corrections after your files have been submitted. #12; JOURNAL PRODUCTION

  8. Program Director/Principal Investigator (Last, First, Middle): DETAILED BUDGET FOR INITIAL BUDGET PERIOD

    E-Print Network [OSTI]

    Ungerleider, Leslie G.

    Program Director/Principal Investigator (Last, First, Middle): DETAILED BUDGET FOR INITIAL BUDGET SUBTOTAL DIRECT COSTS FOR INITIAL BUDGET PERIOD (Item 7a, Face Page) $ CONSORTIUM/CONTRACTUAL COSTS FACILITIES AND ADMINISTRATIVE COSTS TOTAL DIRECT COSTS FOR INITIAL BUDGET PERIOD $ PHS 398 (Rev. 6/09) Page

  9. Program Director/Principal Investigator (Last, First, Middle): DETAILED BUDGET FOR NEXT BUDGET

    E-Print Network [OSTI]

    Baker, Chris I.

    Program Director/Principal Investigator (Last, First, Middle): DETAILED BUDGET FOR NEXT BUDGET by category) OTHER EXPENSES (Itemize by category) SUBTOTAL DIRECT COSTS FOR NEXT BUDGET PERIOD $ CONSORTIUM FOR NEXT BUDGET PERIOD (Item 8a, Face Page) $ Page Form Page 2PHS 2590 (Rev. 08/12) #12;

  10. Program Director/Principal Investigator (Last, First, Middle): DETAILED BUDGET FOR INITIAL BUDGET PERIOD

    E-Print Network [OSTI]

    Baker, Chris I.

    Program Director/Principal Investigator (Last, First, Middle): DETAILED BUDGET FOR INITIAL BUDGET SUBTOTAL DIRECT COSTS FOR INITIAL BUDGET PERIOD (Item 7a, Face Page) $ CONSORTIUM/CONTRACTUAL COSTS FACILITIES AND ADMINISTRATIVE COSTS TOTAL DIRECT COSTS FOR INITIAL BUDGET PERIOD $ Page Form Page 4 PHS 398

  11. Characteristics of potential repository wastes: Volume 4, Appendix 4A, Nuclear reactors at educational institutions of the United States; Appendix 4B, Data sheets for nuclear reactors at educational institutions; Appendix 4C, Supplemental data for Fort St. Vrain spent fuel; Appendix 4D, Supplemental data for Peach Bottom 1 spent fuel; Appendix 4E, Supplemental data for Fast Flux Test Facility

    SciTech Connect (OSTI)

    Not Available

    1992-07-01T23:59:59.000Z

    Volume 4 contains the following appendices: nuclear reactors at educational institutions in the United States; data sheets for nuclear reactors at educational institutions in the United States(operational reactors and shut-down reactors); supplemental data for Fort St. Vrain spent fuel; supplemental data for Peach Bottom 1 spent fuel; and supplemental data for Fast Flux Test Facility.

  12. Location and design of a competitive facility for profit maximisation

    E-Print Network [OSTI]

    A single facility has to be located in competition with fixed existing facilities of .... xa and a strictly positive weight ?a, supposed to be an indicator of its buying ...

  13. 2013 Fall Commencement Receptions College/School Time Location

    E-Print Network [OSTI]

    Pittendrigh, Barry

    2013 Fall Commencement Receptions College/School Time Location Agriculture 12/15 after ceremony@purdue.edu Nuclear 12/15 11:30-1:00 Nuclear Engineering Bldg, Rm 115 For more info Chrystal Randler (765

  14. Position: Forestry Intern Location: Lower Suwannee National Wildlife Refuge

    E-Print Network [OSTI]

    Mazzotti, Frank

    Position: Forestry Intern Location: Lower Suwannee National Wildlife Refuge Application Process: Student Conservation Association (SCA) Forestry and biological Wildlife Refuge. This forestry position will be mostly field work within the Lower

  15. accident location analysis: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    At the end, some safety-related recommendations are listed. Balda, F 2002-01-01 54 Multivariate data analysis based on two location vectors and two scatter matrices...

  16. Identification of critical locations across multiple infrastructures for terrorist actions

    E-Print Network [OSTI]

    Patterson, Sean A. (Sean Albert), 1981-

    2005-01-01T23:59:59.000Z

    This paper discusses a possible approach to ranking geographic regions that can influence multiple infrastructures. Once ranked, decision makers can determine whether these regions are critical locations based on their ...

  17. Location and Institution SOUTH AFRICA -PRETORIA FORDHAM UNIVERSITY -UBUNTU PROGRAM

    E-Print Network [OSTI]

    Galles, David

    Location and Institution SOUTH AFRICA - PRETORIA FORDHAM UNIVERSITY - UBUNTU demographics, and South Africa. Students will also take a required module in Sociology holders need a student visa to enter and study in South Africa, which must

  18. arbitrarily located electric: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    efficiently manage the electricity cost of distributed IDCs based on the Locational Marginal Pricing (LMP Rahman, A.K.M. Ashikur 475 Proper Use of ElectricGas UtilityType...

  19. Methods for short-circuit identification and location in automobiles

    E-Print Network [OSTI]

    Crumlin, Alex Justin

    2006-01-01T23:59:59.000Z

    As the number of electrical components in cars increases at a rapid rate, so too does the chance for electrical failure. A method for locating shorts to the chassis of a car is developed in this thesis. The developed ...

  20. Short & long run transmission incentives for generation location

    E-Print Network [OSTI]

    Turvey, Ralph

    2006-01-01T23:59:59.000Z

    This paper is about one aspect of Britain's electricity trading system, its advantages and its weaknesses concerning the incentives it provides or fails to provide for the location of generation. (Similar considerations ...

  1. ambulance location monitoring: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    model adds a dependence on the datatype used to derive the location. M. S. Briggs; G. N. Pendleton; J. J. Brainerd; V. Connaughton; R. M. Kippen; C. Meegan; K. Hurley...

  2. Infill location determination and assessment of corresponding uncertainty

    E-Print Network [OSTI]

    Senel, Ozgur

    2009-05-15T23:59:59.000Z

    tried to solve this problem with statistical approaches. In this study, a reservoir simulation based approach was used to select infill well locations. I used multiple reservoir realizations to take different possible outcomes into consideration...

  3. Scalable Energy Efficient Location Aware Multicast Protocol for MANET (SEELAMP)

    E-Print Network [OSTI]

    Kamboj, Pariza

    2010-01-01T23:59:59.000Z

    Multicast plays an important role in implementing the group communications in bandwidth scarce multihop mobile ad hoc networks. However, due to the dynamic topology of MANETs it is very difficult to build optimal multicast trees and maintaining group membership, making even more challenging to implement scalable and robust multicast in Mobile Ad hoc Networks (MANET). A scalable and energy efficient location aware multicast algorithm, called SEELAMP, for mobile ad hoc networks is presented in the paper that is based on creation of shared tree using the physical location of the nodes for the multicast sessions. It constructs a shared bi-directional multicast tree for its routing operations rather than a mesh, which helps in achieving more efficient multicast delivery. The algorithm uses the concept of small overlapped zones around each node for proactive topology maintenance with in the zone. Protocol depends on the location information obtained using a distributed location service, which effectively reduces th...

  4. New approach to the fault location problem using synchronized sampling

    E-Print Network [OSTI]

    Mrkic, Jasna

    1994-01-01T23:59:59.000Z

    This thesis presents a new approach to solving the problem of fault location on a transmission line using synchronized data from both ends of the line. The synchronized phase voltage and current samples taken during the fault transient are used...

  5. accident locations: Topics by E-print Network

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Exact Location : Date of Accident : AM PM Environmental Sciences and Ecology Websites Summary: SSN Cell Phone Home...

  6. Testing geopressured geothermal reservoirs in existing wells: Detailed completion prognosis for geopressured-geothermal well of opportunity, prospect #7

    SciTech Connect (OSTI)

    Godchaux, Frank A.

    1981-06-01T23:59:59.000Z

    This book is a detailed prognosis covering the acquisition, completion, drilling, testing and abandonment of the Frank A. Godchaux, III, Well No. 1 under the Wells of Opportunity Program. The well is located approximately 12 miles southeast of the city of Abbeville, Louisiana. Eaton Operating Company proposes to test a section of the Planulina sand at a depth ranging from 15,584 to 15,692 feet. The reservoir pressure is estimated to be 14,480 psi and the temperature of the formation water is expected to be 298 F. The water salinity is calculated to be 75,000 ppm. The well is expected to produce 20,000 barrels of water per day with a gas content of 44 standard cubic feet pre barrel. The well was acquired from C and K Petroleu, Inc. on March 20, 1981. C and K abandoned the well at a total depth of 16,000 feet. The well has a 7-5/8 inches liner set at 13,387 feet. Eaton proposes to set 5-1/2 inch casing at 16,000 feet and produce the well through the casing using a 2-3/8 inch tubing string for wireline protection and for pressure control. A 4,600 foot saltwater disposal well will be drilled on the site and testing will be conducted similar to previous Eaton tests. The total estimated cost to perform the work is $2,959,000. An optional test from 14,905 to 15,006 feet may be performed after the original test and will require a workover with a rig on location to perform the plugback. The surface production equipment utilized on previous Eaton WOO tests will be utilized on this test. This equipment has worked satisfactorily and all parties involved in the testing are familiar with its operation. The Institute of Gas Technology and Mr. Don Clark will handle the sampling and testing and reservoir evaluation, respectively, as on the previous Eaton tests.

  7. Location of the solar dynamo and near-surface shear

    E-Print Network [OSTI]

    Axel Brandenburg

    2005-12-29T23:59:59.000Z

    The location of the solar dynamo is discussed in the context of new insights into the theory of nonlinear turbulent dynamos. It is argued that, from a dynamo-theoretic point of view, the bottom of the convection zone is not a likely location and that the solar dynamo may be distributed over the convection zone. The near surface shear layer produces not only east-west field alignment, but it also helps the dynamo disposing of its excess small scale magnetic helicity.

  8. Predicting threshold and location of laser damage on optical surfaces

    DOE Patents [OSTI]

    Siekhaus, Wigbert (Berkeley, CA)

    1987-01-01T23:59:59.000Z

    An apparatus useful in the prediction of the damage threshold of various optical devices, the location of weak spots on such devices and the location, identification, and elimination of optical surface impurities comprising, a focused and pulsed laser, an photo electric detector/imaging means, and a timer. The weak spots emit photoelectrons when subjected to laser intensities that are less than the intensity actually required to produce the damage. The weak spots may be eliminated by sustained exposure to the laser beam.

  9. Detailed microscopic calculation of stellar electron and positron capture rates on $^{24}$Mg for O+Ne+Mg core simulations

    E-Print Network [OSTI]

    Jameel-Un Nabi

    2014-08-15T23:59:59.000Z

    Few white dwarfs, located in binary systems, may acquire sufficiently high mass accretion rates resulting in the burning of carbon and oxygen under nondegenerate conditions forming a O+Ne+Mg core. These O+Ne+Mg cores are gravitationally less bound than more massive progenitor stars and can release more energy due to the nuclear burning. They are also amongst the probable candidates for low entropy r-process sites. Recent observations of subluminous Type II-P supernovae (e.g., 2005cs, 2003gd, 1999br, 1997D) were able to rekindle the interest in 8 -- 10 M$_{\\odot}$ which develop O+Ne+Mg cores. Microscopic calculations of capture rates on $^{24}$Mg, which may contribute significantly to the collapse of O+Ne+Mg cores, using shell model and proton-neutron quasiparticle random phase approximation (pn-QRPA) theory, were performed earlier and comparisons made. Simulators, however, may require these capture rates on a fine scale. For the first time a detailed microscopic calculation of the electron and positron capture rates on $^{24}$Mg on an extensive temperature-density scale is presented here. This type of scale is more appropriate for interpolation purposes and of greater utility for simulation codes. The calculations are done using the pn-QRPA theory using a separable interaction. The deformation parameter, believed to be a key parameter in QRPA calculations, is adopted from experimental data to further increase the reliability of the QRPA results. The resulting calculated rates are up to a factor of 14 or more enhanced as compared to shell model rates and may lead to some interesting scenario for core collapse simulators.

  10. THE LOCATIONS OF SHORT GAMMA-RAY BURSTS AS EVIDENCE FOR COMPACT OBJECT BINARY PROGENITORS

    SciTech Connect (OSTI)

    Fong, W.; Berger, E. [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States)

    2013-10-10T23:59:59.000Z

    We present a detailed investigation of Hubble Space Telescope rest-frame UV/optical observations of 22 short gamma-ray burst (GRB) host galaxies and sub-galactic environments. Utilizing the high angular resolution and depth of HST we characterize the host galaxy morphologies, measure precise projected physical and host-normalized offsets between the bursts and host centers, and calculate the locations of the bursts with respect to their host light distributions (rest-frame UV and optical). We calculate a median short GRB projected physical offset of 4.5 kpc, about 3.5 times larger than that for long GRBs, and find that ?25% of short GRBs have offsets of ?> 10 kpc. When compared to their host sizes, the median offset is 1.5 half-light radii (r{sub e} ), about 1.5 times larger than the values for long GRBs, core-collapse supernovae, and Type Ia supernovae. In addition, ?20% of short GRBs having offsets of ?> 5r{sub e} , and only ?25% are located within 1r{sub e} . We further find that short GRBs severely under-represent their hosts' rest-frame optical and UV light, with ?30%-45% of the bursts located in regions of their host galaxies that have no detectable stellar light, and ?55% in the regions with no UV light. Therefore, short GRBs do not occur in regions of star formation or even stellar mass. This demonstrates that the progenitor systems of short GRBs must migrate from their birth sites to their eventual explosion sites, a signature of kicks in compact object binary systems. Utilizing the full sample of offsets, we estimate natal kick velocities of ?20-140 km s{sup –1}. These independent lines of evidence provide the strongest support to date that short GRBs result from the merger of compact object binaries (NS-NS/NS-BH)

  11. On power-counting renormalizability of Ho?ava gravity with detailed balance

    E-Print Network [OSTI]

    Daniele Vernieri

    2015-02-23T23:59:59.000Z

    We consider the version of Ho\\v{r}ava gravity where "detailed balance" is consistently implemented, such as to limitate the huge proliferation of couplings in the full theory and to obtain an healthy dynamics at low-energy. Since a superpotential which is third-order in spatial derivatives is not sufficient to guarantee the power-counting renormalizability of the spin-0 graviton, then one needs to go an order beyond in derivatives, building up a superpotential up to fourth-order spatial derivatives. Here, we perturb the action to quadratic order around flat space, and show that power-counting renormalizability of the spin-0 graviton is achieved only by setting to zero a specific coupling of the theory, while the spin-2 graviton is always power-counting renormalizable for any choice of the couplings. This result raises serious doubts about the use of detailed balance.

  12. On power-counting renormalizability of Ho\\v{r}ava gravity with detailed balance

    E-Print Network [OSTI]

    Vernieri, Daniele

    2015-01-01T23:59:59.000Z

    We consider the version of Ho\\v{r}ava gravity where "detailed balance" is consistently implemented, such as to limitate the huge proliferation of couplings in the full theory and to obtain an healthy dynamics at low-energy. Since a superpotential which is third-order in spatial derivatives is not sufficient to guarantee the power-counting renormalizability of the spin-0 graviton, then one needs to go an order beyond in derivatives, building up a superpotential up to fourth-order spatial derivatives. Here, we perturb the action to quadratic order around flat space, and show that power-counting renormalizability of the spin-0 graviton is achieved only by setting to zero a specific coupling of the theory, while the spin-2 graviton is always power-counting renormalizable for any choice of the couplings. This result raises serious doubts about the use of detailed balance.

  13. Solid Waste Operations Complex W-113, Detail Design Report (Title II). Volume 2: Solid waste retrieval facilities -- Phase 1, detail design drawings

    SciTech Connect (OSTI)

    NONE

    1995-09-01T23:59:59.000Z

    The Solid Waste Retrieval Facility--Phase 1 (Project W113) will provide the infrastructure and the facility required to retrieve from Trench 04, Burial ground 4C, contact handled (CH) drums and boxes at a rate that supports all retrieved TRU waste batching, treatment, storage, and disposal plans. This includes (1) operations related equipment and facilities, viz., a weather enclosure for the trench, retrieval equipment, weighing, venting, obtaining gas samples, overpacking, NDE, NDA, shipment of waste and (2) operations support related facilities, viz., a general office building, a retrieval staff change facility, and infrastructure upgrades such as supply and routing of water, sewer, electrical power, fire protection, roads, and telecommunication. Title I design for the operations related equipment and facilities was performed by Raytheon/BNFL, and that for the operations support related facilities including infrastructure upgrade was performed by KEH. These two scopes were combined into an integrated W113 Title II scope that was performed by Raytheon/BNFL. Volume 2 provides the complete set of the Detail Design drawings along with a listing of the drawings. Once approved by WHC, these drawings will be issued and baselined for the Title 3 construction effort.

  14. Diffusive transport without detailed balance in motile bacteria: Does microbiology need statistical physics?

    E-Print Network [OSTI]

    M. E. Cates

    2012-08-20T23:59:59.000Z

    Microbiology is the science of microbes, particularly bacteria. Many bacteria are motile: they are capable of self-propulsion. Among these, a significant class execute so-called run-and-tumble motion: they follow a fairly straight path for a certain distance, then abruptly change direction before repeating the process. This dynamics has something in common with Brownian motion (it is diffusive at large scales), and also something in contrast. Specifically, motility parameters such as the run speed and tumble rate depend on the local environment and hence can vary in space. When they do so, even if a steady state is reached, this is not generally invariant under time-reversal: the principle of detailed balance, which restores the microscopic time-reversal symmetry of systems in thermal equilibrium, is mesoscopically absent in motile bacteria. This lack of detailed balance (allowed by the flux of chemical energy that drives motility) creates pitfalls for the unwary modeller. Here I review some statistical mechanical models for bacterial motility, presenting them as a paradigm for exploring diffusion without detailed balance. I also discuss the extent to which statistical physics is useful in understanding real or potential microbiological experiments.

  15. The Role of Comprehensive Detailed Chemical Kinetic Reaction Mechanisms in Combustion Research

    SciTech Connect (OSTI)

    Westbrook, C K; Pitz, W J; Curran, H J; Mehl, M

    2008-07-16T23:59:59.000Z

    Recent developments by the authors in the field of comprehensive detailed chemical kinetic reaction mechanisms for hydrocarbon fuels are reviewed. Examples are given of how these mechanisms provide fundamental chemical insights into a range of combustion applications. Practical combustion consists primarily of chemical heat release from reactions between a fuel and an oxidizer, and computer simulations of practical combustion systems have become an essential tool of combustion research (Westbrook et al., 2005). At the heart of most combustion simulations, the chemical kinetic submodel frequently is the most detailed, complex and computationally costly part of a system model. Historically, the chemical submodel equations are solved using time-implicit numerical algorithms, due to the extreme stiffness of the coupled rate equations, with a computational cost that varies roughly with the cube of the number of chemical species in the model. While early mechanisms (c. 1980) for apparently simple fuels such as methane (Warnatz, 1980) or methanol (Westbrook and Dryer, 1979) included perhaps 25 species, current detailed mechanisms for much larger, more complex fuels such as hexadecane (Fournet et al., 2001; Ristori et al., 2001; Westbrook et al., 2008) or methyl ester methyl decanoate (Herbinet et al., 2008) have as many as 2000 or even 3000 species. Rapid growth in capabilities of modern computers has been an essential feature in this rapid growth in the size and complexity of chemical kinetic reaction mechanisms.

  16. Development and validation of detailed controls models of the Nelson River Bipole 1 HVDC system

    SciTech Connect (OSTI)

    Kuffel, P.; Kent, K.L.; Mazur, G.B.; Weekes, M.A. (Manitoba Hydro, Winnipeg (Canada))

    1993-01-01T23:59:59.000Z

    With the Nelson River Bipole 1 mercury arc valve group replacement project and planning for the expansion of the Nelson River HVDC system with a third bipole underway, it was decided to pursue a program to develop and validate detailed models of the existing HVDC transmission facilities and their associated ac systems for use in system studies. The first phase of the program concentrated on the development of detailed controls models associated with the Bipole 1 transmission facility. Based on previous experience at Manitoba Hydro with the Electromagnetic Transient DC simulation program (EMTDC), it was decided that model development and validation would use this program. This paper presents the reasons behind the development of detailed models, the methods used in developing models related to Bipole 1, results of validation tests, difficulties encountered during the process, and the overall benefits resulting from the project. An example of applying the models to investigate a low frequency oscillation which has occurred on the dc system in the past is also presented.

  17. Impurity-doped optical shock, detonation and damage location sensor

    DOE Patents [OSTI]

    Weiss, J.D.

    1995-02-07T23:59:59.000Z

    A shock, detonation, and damage location sensor providing continuous fiber-optic means of measuring shock speed and damage location, and could be designed through proper cabling to have virtually any desired crush pressure. The sensor has one or a plurality of parallel multimode optical fibers, or a singlemode fiber core, surrounded by an elongated cladding, doped along their entire length with impurities to fluoresce in response to light at a different wavelength entering one end of the fiber(s). The length of a fiber would be continuously shorted as it is progressively destroyed by a shock wave traveling parallel to its axis. The resulting backscattered and shifted light would eventually enter a detector and be converted into a proportional electrical signals which would be evaluated to determine shock velocity and damage location. The corresponding reduction in output, because of the shortening of the optical fibers, is used as it is received to determine the velocity and position of the shock front as a function of time. As a damage location sensor the sensor fiber cracks along with the structure to which it is mounted. The size of the resulting drop in detector output is indicative of the location of the crack. 8 figs.

  18. Impurity-doped optical shock, detonation and damage location sensor

    DOE Patents [OSTI]

    Weiss, Jonathan D. (Albuquerque, NM)

    1995-01-01T23:59:59.000Z

    A shock, detonation, and damage location sensor providing continuous fiber-optic means of measuring shock speed and damage location, and could be designed through proper cabling to have virtually any desired crush pressure. The sensor has one or a plurality of parallel multimode optical fibers, or a singlemode fiber core, surrounded by an elongated cladding, doped along their entire length with impurities to fluoresce in response to light at a different wavelength entering one end of the fiber(s). The length of a fiber would be continuously shorted as it is progressively destroyed by a shock wave traveling parallel to its axis. The resulting backscattered and shifted light would eventually enter a detector and be converted into a proportional electrical signals which would be evaluated to determine shock velocity and damage location. The corresponding reduction in output, because of the shortening of the optical fibers, is used as it is received to determine the velocity and position of the shock front as a function of time. As a damage location sensor the sensor fiber cracks along with the structure to which it is mounted. The size of the resulting drop in detector output is indicative of the location of the crack.

  19. Prognostic Importance of Gleason 7 Disease Among Patients Treated With External Beam Radiation Therapy for Prostate Cancer: Results of a Detailed Biopsy Core Analysis

    SciTech Connect (OSTI)

    Spratt, Daniel E.; Zumsteg, Zach; Ghadjar, Pirus; Pangasa, Misha; Pei, Xin [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)] [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Fine, Samson W. [Department of Pathology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)] [Department of Pathology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Yamada, Yoshiya; Kollmeier, Marisa [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)] [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States); Zelefsky, Michael J., E-mail: zelefskm@mskcc.org [Department of Radiation Oncology, Memorial Sloan-Kettering Cancer Center, New York, New York (United States)

    2013-04-01T23:59:59.000Z

    Purpose: To analyze the effect of primary Gleason (pG) grade among a large cohort of Gleason 7 prostate cancer patients treated with external beam radiation therapy (EBRT). Methods and Materials: From May 1989 to January 2011, 1190 Gleason 7 patients with localized prostate cancer were treated with EBRT at a single institution. Of these patients, 613 had a Gleason 7 with a minimum of a sextant biopsy with nonfragmented cores and full biopsy core details available, including number of cores of cancer involved, percentage individual core involvement, location of disease, bilaterality, and presence of perineural invasion. Median follow-up was 6 years (range, 1-16 years). The prognostic implication for the following outcomes was analyzed: biochemical recurrence-free survival (bRFS), distant metastasis-free survival (DMFS), and prostate cancer-specific mortality (PCSM). Results: The 8-year bRFS rate for pG3 versus pG4 was 77.6% versus 61.3% (P<.0001), DMFS was 96.8% versus 84.3% (P<.0001), and PCSM was 3.7% versus 8.1% (P=.002). On multivariate analysis, pG4 predicted for significantly worse outcome in all parameters. Location of disease (apex, base, mid-gland), perineural involvement, maximum individual core involvement, and the number of Gleason 3+3, 3+4, or 4+3 cores did not predict for distant metastases. Conclusions: Primary Gleason grade 4 independently predicts for worse bRFS, DMFS, and PCSM among Gleason 7 patients. Using complete core information can allow clinicians to utilize pG grade as a prognostic factor, despite not having the full pathologic details from a prostatectomy specimen. Future staging and risk grouping should investigate the incorporation of primary Gleason grade when complete biopsy core information is used.

  20. Coupling geostatistics to detailed reservoir description allows better visualization and more accurate characterization/simulation of turbidite reservoirs: Elk Hills oil field, California

    SciTech Connect (OSTI)

    Allan, M.E.; Wilson, M.L.; Wightman, J. [Bechtel Petroleum, Elk Hills, CA (United States)

    1996-12-31T23:59:59.000Z

    The Elk Hills giant oilfield, located in the southern San Joaquin Valley of California, has produced 1.1 billion barrels of oil from Miocene and shallow Pliocene reservoirs. 65% of the current 64,000 BOPD production is from the pressure-supported, deeper Miocene turbidite sands. In the turbidite sands of the 31 S structure, large porosity & permeability variations in the Main Body B and Western 31 S sands cause problems with the efficiency of the waterflooding. These variations have now been quantified and visualized using geostatistics. The end result is a more detailed reservoir characterization for simulation. Traditional reservoir descriptions based on marker correlations, cross-sections and mapping do not provide enough detail to capture the short-scale stratigraphic heterogeneity needed for adequate reservoir simulation. These deterministic descriptions are inadequate to tie with production data as the thinly bedded sand/shale sequences blur into a falsely homogenous picture. By studying the variability of the geologic & petrophysical data vertically within each wellbore and spatially from well to well, a geostatistical reservoir description has been developed. It captures the natural variability of the sands and shales that was lacking from earlier work. These geostatistical studies allow the geologic and petrophysical characteristics to be considered in a probabilistic model. The end-product is a reservoir description that captures the variability of the reservoir sequences and can be used as a more realistic starting point for history matching and reservoir simulation.

  1. Coupling geostatistics to detailed reservoir description allows better visualization and more accurate characterization/simulation of turbidite reservoirs: Elk Hills oil field, California

    SciTech Connect (OSTI)

    Allan, M.E.; Wilson, M.L.; Wightman, J. (Bechtel Petroleum, Elk Hills, CA (United States))

    1996-01-01T23:59:59.000Z

    The Elk Hills giant oilfield, located in the southern San Joaquin Valley of California, has produced 1.1 billion barrels of oil from Miocene and shallow Pliocene reservoirs. 65% of the current 64,000 BOPD production is from the pressure-supported, deeper Miocene turbidite sands. In the turbidite sands of the 31 S structure, large porosity permeability variations in the Main Body B and Western 31 S sands cause problems with the efficiency of the waterflooding. These variations have now been quantified and visualized using geostatistics. The end result is a more detailed reservoir characterization for simulation. Traditional reservoir descriptions based on marker correlations, cross-sections and mapping do not provide enough detail to capture the short-scale stratigraphic heterogeneity needed for adequate reservoir simulation. These deterministic descriptions are inadequate to tie with production data as the thinly bedded sand/shale sequences blur into a falsely homogenous picture. By studying the variability of the geologic petrophysical data vertically within each wellbore and spatially from well to well, a geostatistical reservoir description has been developed. It captures the natural variability of the sands and shales that was lacking from earlier work. These geostatistical studies allow the geologic and petrophysical characteristics to be considered in a probabilistic model. The end-product is a reservoir description that captures the variability of the reservoir sequences and can be used as a more realistic starting point for history matching and reservoir simulation.

  2. A flexible location management scheme for mobile computing

    E-Print Network [OSTI]

    Zhang, Ying

    1996-01-01T23:59:59.000Z

    , ation B. Distril?Ite&1 Datahase Management System (DBMS) . C. Prototype Design and Conhgurat, ion 24 24 99 vn CHAPTER Pa. ge IV EXPERIMENTAL RESULTS . A. ExpeHmental Results B. Analytic Results 38 V CONCLUSION REFERENCES 43 VITA 47 vn1... rent l)DBMS's. tVe have cleveloped an experimental prototype t, hat rc&nsiclers these charact, eris- tics of a, location mauagen&ent system. The nltin&ate purpose of' this prototype is to demonstrate the feasibility of our proposecl location...

  3. Predicting threshold and location of laser damage on optical surfaces

    DOE Patents [OSTI]

    Siekhaus, W.

    1985-02-04T23:59:59.000Z

    Disclosed is an apparatus useful in the prediction of the damage threshold of various optical devices, the location of weak spots on such devices and the location, identification, and elimination of optical surface impurities. The apparatus comprises a focused and pulsed laser, a photo electric detector/imaging means, and a timer. The weak spots emit photoelectrons when subjected to laser intensities that are less than the intensity actually required to produce the damage. The weak spots may be eliminated by sustained exposure to the laser beam.

  4. Modeling HCCI using CFD and Detailed Chemistry with Experimental Validation and a Focus on CO Emissions

    SciTech Connect (OSTI)

    Hessel, R; Foster, D; Aceves, S; Flowers, D; Pitz, B; Dec, J; Sjoberg, M; Babajimopoulos, A

    2007-04-23T23:59:59.000Z

    Multi-zone CFD simulations with detailed kinetics were used to model engine experiments performed on a diesel engine that was converted for single cylinder, HCCI operation, here using iso-octane as the fuel. The modeling goals were to validate the method (multi-zone combustion modeling) and the reaction mechanism (LLNL 857 species iso-octane), both of which performed very well. The purpose of this paper is to document the validation findings and to set the ground work for further analysis of the results by first looking at CO emissions characteristics with varying equivalence ratio.

  5. Detailed analysis of quantum phase transitions within the $u(2)$ algebra

    E-Print Network [OSTI]

    L. Fortunato; L. Sartori

    2009-10-13T23:59:59.000Z

    We analyze in detail the quantum phase transitions that arise in models based on the $u(2)$ algebraic description for bosonic systems with two types of scalar bosons. First we discuss the quantum phase transition that occurs in hamiltonians that admix the two dynamical symmetry chains $u(2)\\supset u(1)$ and $u(2)\\supset so(2)$ by diagonalizing the problem exactly in the $u(1)$ basis. Then we apply the coherent state formalism to determine the energy functional. Finally we show that a quantum phase transition of a different nature, but displaying similar characteristics, may arise also within a single chain just by including higher order terms in the hamiltonian.

  6. Deciphering the details of RNA aminoglycoside interactions: from atomistic models to biotechnological applications

    SciTech Connect (OSTI)

    Ilgu, Muslum

    2012-07-23T23:59:59.000Z

    A detailed study was done of the neomycin-B RNA aptamer for determining its selectivity and binding ability to both neomycin– and kanamycin-class aminoglycosides. A novel method to increase drug concentrations in cells for more efficiently killing is described. To test the method, a bacterial model system was adopted and several small RNA molecules interacting with aminoglycosides were cloned downstream of T7 RNA polymerase promoter in an expression vector. Then, the growth analysis of E. coli expressing aptamers was observed for 12-hour period. Our analysis indicated that aptamers helped to increase the intracellular concentration of aminoglycosides thereby increasing their efficacy.

  7. A study of clear-air turbulence from detailed wind profiles over Cape Kennedy, Florida 

    E-Print Network [OSTI]

    Blackburn, James Harvey

    1969-01-01T23:59:59.000Z

    A STUDY OF CLEAR-AIR TURBULENCE FROM DETAII. ED WIND PROFILES OVER CAPE KENNEDY, FLORIDA A Thesis by James Harvey Blackburn, Jr. Captain United States Air Force Approved as to style and content by: (Chairman of ittee) (Head of Dep tment...) (Amber) (Member) May 1969 ABSTRACT A Study of Clear-Air Turbulence from Detailed Wind Profiles Over Cape Kennedy, Florida. James H. Blackburn, Jr. , B. S. , Texas A6N University Directed by: Dr. James R. Scoggins Clear-air turbulence (CAT...

  8. A DETAILED COMPARISON BETWEEN THE OBSERVED AND SYNTHESIZED PROPERTIES OF A SIMULATED TYPE II SPICULE

    SciTech Connect (OSTI)

    Martinez-Sykora, Juan; De Pontieu, Bart; Pereira, Tiago M. D.; Stern, Julie V. [Lockheed Martin Solar and Astrophysics Laboratory, Palo Alto, CA 94304 (United States); Leenaarts, Jorrit; Carlsson, Mats; Hansteen, Viggo; Van der Voort, Luc Rouppe [Institute of Theoretical Astrophysics, University of Oslo, P.O. Box 1029 Blindern, N-0315 Oslo (Norway); Tian Hui [Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138 (United States); McIntosh, Scott W., E-mail: j.m.sykora@astro.uio.no [High Altitude Observatory, National Center for Atmospheric Research, Boulder, CO 80307 (United States)

    2013-07-01T23:59:59.000Z

    We have performed a three-dimensional radiative MHD simulation of the solar atmosphere. This simulation shows a jet-like feature that shows similarities to the type II spicules observed for the first time with Hinode's Solar Optical Telescope. Rapid blueshifted events (RBEs) on the solar disk are associated with these spicules. Observational results suggest they may contribute significantly in supplying the corona with hot plasma. We perform a detailed comparison of the properties of the simulated jet with those of type II spicules (observed with Hinode) and RBEs (with ground-based instruments). We analyze a wide variety of synthetic emission and absorption lines from the simulations including chromospheric (Ca II 8542 A, Ca II H, and H{alpha}) to transition region and coronal temperatures (10,000 K to several million K). We compare their synthetic intensities, line profiles, Doppler shifts, line widths, and asymmetries with observations from Hinode/SOT and EIS, SOHO/SUMER, the Swedish 1 m Solar Telescope, and SDO/AIA. Many properties of the synthetic observables resemble the observations, and we describe in detail the physical processes that lead to these observables. Detailed analysis of the synthetic observables provides insight into how observations should be analyzed to derive information about physical variables in such a dynamic event. For example, we find that line-of-sight superposition in the optically thin atmosphere requires the combination of Doppler shifts and spectral line asymmetry to determine the velocity in the jet. In our simulated type II spicule, the lifetime of the asymmetry of the transition region lines is shorter than that of the coronal lines. Other properties differ from the observations, especially in the chromospheric lines. The mass density of the part of the spicule with a chromospheric temperature is too low to produce significant opacity in chromospheric lines. The synthetic Ca II 8542 A and H{alpha} profiles therefore do not show signal resembling RBEs. These and other discrepancies are described in detail, and we discuss which mechanisms and physical processes may need to be included in the MHD simulations to mimic the thermodynamic processes of the chromosphere and corona, in particular to reproduce type II spicules.

  9. Detailed Monthly and Annual LNG Import Statistics (2004-2012) | Department

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you0andEnergyGlobal Nuclearof aDepartment-of Energy Detailed Monthly and

  10. Details of the FY 2014 Budget Request for FE | Department of Energy

    Energy Savers [EERE]

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page onYou are now leaving Energy.gov You are now leaving Energy.gov You are being directed off Energy.gov. Are you0andEnergyGlobal Nuclearof aDepartment-of Energy Detailed Monthly

  11. Details of the FY 2014 Congressional Budget Request for OE | Department of

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page onYouTube YouTube Note: Since the YouTube| DepartmentStatementDepartment ofVisits KazakhstanSummitMillofDetails of the

  12. OnLocation, Inc., Energy Systems Consulting Hydrogen Scenarios

    E-Print Network [OSTI]

    Delivery Analysis Meeting by Frances Wood OnLocation, Inc. Energy Systems Consulting May 9, 2007 #12;On simulates energy production, consumption, and conversion sectors ­ including hydrogen. D e m a n d C o m p o Activity Module Macroeconomic Activity Module Oil and Gas Supply Module Nat. Gas T&D Module Renewable Fuels

  13. Engineering and Computing Open Day Programme 2012 Activity Time Location

    E-Print Network [OSTI]

    Berzins, M.

    Engineering and Computing Open Day Programme 2012 Activity Time Location Building Number What is Engineering? (Talk) 0900 - 0945 Electronic and Electrical Engineering, Rhodes Lecture Theatre 51 1000 - 1045 EC Stoner Building, School of Computing, Reception (Level 7) 73 Electronic Engineering (Talk) 1000

  14. Connectivity Based Location Estimation Scheme for Wireless Ad Hoc Networks

    E-Print Network [OSTI]

    Ramanathan, Parameswaran "Parmesh"

    Connectivity Based Location Estimation Scheme for Wireless Ad Hoc Networks Niveditha Sundaram. The loca- tion estimates rely on neighborhood relationships gathered by each user through message, form factors, energy consumption, etc., providing GPS support may not be feasible even in outdoor

  15. Geoforum xxx (2007) xxxxxx www.elsevier.com/locate/geoforum

    E-Print Network [OSTI]

    Colorado at Boulder, University of

    2007-01-01T23:59:59.000Z

    Geoforum xxx (2007) xxx­xxx www.elsevier.com/locate/geoforum 0016-7185/$ - see front matter © 2007 contributed equally to the writing of this paper. #12;2 M.T. BoykoV, J.M. BoykoV / Geoforum xxx (2007) xxx­xxx

  16. Rapid location of mount points JONATHAN M. SMITH

    E-Print Network [OSTI]

    ­­ ­­ Rapid location of mount points JONATHAN M. SMITH Computer Science Department, Columbia ``core'' is ``/u2/smith/core''. The current directory is a directory­valued variable. It is an implied traversal; the root contains itself. This scheme is extensible across multiple media through mount points

  17. Building and Facility Codes Code Building Location Bldg # Coordinates

    E-Print Network [OSTI]

    Russell, Lynn

    Building and Facility Codes Code Building Location Bldg # Coordinates APM Applied Physics & Mathematics Building Muir 249 F7 ASANT Asante Hall Eleanor Roosevelt 446 F5 BIO Biology Building Muir 259 F7 BIRCH Birch Aquarium SIO 2300 S-D7 BONN Bonner Hall Revelle 131 G8 BSB Biomedical Sciences Building

  18. Double Difference Earthquake Locations at the Salton Sea Geothermal Reservoir

    SciTech Connect (OSTI)

    Boyle, K L; Hutchings, L J; Bonner, B P; Foxall, W; Kasameyer, P W

    2007-08-08T23:59:59.000Z

    The purpose of this paper is to report on processing of raw waveform data from 4547 events recorded at 12 stations between 2001 and 2005 by the Salton Sea Geothermal Field (SSGF) seismic network. We identified a central region of the network where vertically elongated distributions of hypocenters have previously been located from regional network analysis. We process the data from the local network by first autopicking first P and S arrivals; second, improving these with hand picks when necessary; then, using cross-correlation to provide very precise P and S relative arrival times. We used the HypoDD earthquake location algorithm to locate the events. We found that the originally elongated distributions of hypocenters became more tightly clustered and extend down the extent of the study volume at 10 Km. However, we found the shapes to depend on choices of location parameters. We speculate that these narrow elongated zones of seismicity may be due to stress release caused by fluid flow.

  19. Location-Based Tax Incentives: Evidence From India Ritam Chaurey

    E-Print Network [OSTI]

    Bandyopadhyay, Antar

    in India. Specifically, I examine the federally financed New Industrial Policy for the statesLocation-Based Tax Incentives: Evidence From India Ritam Chaurey Department of Economics, State University of New York, Binghamton August 24, 2014 Abstract While policies targeting particular geographic

  20. Optimizing Controller Location in Networked Control Systems with Packet Drops

    E-Print Network [OSTI]

    Optimizing Controller Location in Networked Control Systems with Packet Drops C. L. Robinson1 and P in answering these two questions is that analysis of optimality in networked control systems subject to random mechanisms for wireless networked control systems [8, 6, 5]. In this paper we consider the issue of optimal