  1. Fire protection design criteria

    SciTech Connect (OSTI)

    1997-03-01

    This Standard provides supplemental fire protection guidance applicable to the design and construction of DOE facilities and site features (such as water distribution systems) that are also provided for fire protection. It is intended to be used in conjunction with the applicable building code, national Fire Protection Association Codes and Standards, and any other applicable DOE construction criteria. This Standard, along with other delineated criteria, constitutes the basic criteria for satisfying DOE fire and life safety objectives for the design and construction or renovation of DOE facilities.

  2. Design Considerations for Fire Safety 

    E-Print Network [OSTI]

    Wilson, A. Grant; Schmidt, William A.; Degenkolb, John G.; Reilly, Edward J.; Robinson, A. Pitts; Sandvik, Robert G.; Semple, J. Brooks

    1971-01-28

    Papers presented at the Symposium on Design Considerations for Fire Safety at the Semiannual Meeting of The American Society of Heating, Refrigerating and Air-conditioning Engineers

  3. Design fires for tunnel water mist suppression systems 

    E-Print Network [OSTI]

    Carvel, Ricky O

    Water mist systems are unable to suppress or control large fires, therefore the ‘design fire’ for a water mist system in a tunnel should not be specified in terms of peak heat release rate, but rather in terms of the ...

  4. FIRE Vacuum Vessel Design and Analysis

    E-Print Network [OSTI]

    quality vacuum - outgassing and leak rate of waste disposal #12;6 June 2001 FIRE Review: Vacuum Vessel Design 8 Vessel shell dimensions #12;6 June - Shielding water + steel with 60% packing factor - Volume of torus interior 35 m^3 - Surface Area of torus

  5. Fire and the Design of Buildings 

    E-Print Network [OSTI]

    McGuire, J

    Fire is one of the major hazards to life and property in buildings. Regulations in respect of fire safety therefore constitute a major part of every building bylaw. These regulations naturally influence the design of almost every building. Good...

  6. ADJECTIVE RATINGS FOR FIRE BEHAVIOR For many years now in America we have used the National Fire Danger Rating System

    E-Print Network [OSTI]

    Danger Rating System (Deeming, et al, 1978) adjective ratings to describe the "fire danger" for a given of descriptive advice of the "danger" of having an ignition based on historic weather data for what kind of fire these ratings meant regarding potential fire behavior. Furthermore, they described "fire danger" which

  7. DOE Standard: Fire protection design criteria

    SciTech Connect (OSTI)

    Not Available

    1999-07-01

    The development of this Standard reflects the fact that national consensus standards and other design criteria do not comprehensively or, in some cases, adequately address fire protection issues at DOE facilities. This Standard provides supplemental fire protection guidance applicable to the design and construction of DOE facilities and site features (such as water distribution systems) that are also provided for fire protection. It is intended to be used in conjunction with the applicable building code, National Fire Protection Association (NFPA) Codes and Standards, and any other applicable DOE construction criteria. This Standard replaces certain mandatory fire protection requirements that were formerly in DOE 5480.7A, ``Fire Protection``, and DOE 6430.1A, ``General Design Criteria``. It also contains the fire protection guidelines from two (now canceled) draft standards: ``Glove Box Fire Protection`` and ``Filter Plenum Fire Protection``. (Note: This Standard does not supersede the requirements of DOE 5480.7A and DOE 6430.1A where these DOE Orders are currently applicable under existing contracts.) This Standard, along with the criteria delineated in Section 3, constitutes the basic criteria for satisfying DOE fire and life safety objectives for the design and construction or renovation of DOE facilities.

  8. FIRE Plasma Facing Components Pre-Conceptual Design

    E-Print Network [OSTI]

    , a Lockheed Martin Company, for the United States Department of Energy under contract DE-AC04-94AL85000. #12FIRE Plasma Facing Components Pre-Conceptual Design Michael Ulrickson Presented at Fusion Summer rate required for He removal ­ Fusion burn rate 1 x 1020/s (200 MW) ­ He fraction in the divertor 0

  9. Travelling Fires for Structural Design 

    E-Print Network [OSTI]

    Stern-Gottfried, Jamie

    Traditional methods for specifying thermal inputs for the structural fire analysis of buildings assume uniform burning and homogeneous temperature conditions throughout a compartment, regardless of its size. This is in ...

  10. VARIABLE FIRING RATE OIL BURNER USING PULSE FUEL FLOW CONTROL.

    SciTech Connect (OSTI)

    KRISHNA,C.R.; BUTCHER,T.A.; KAMATH,B.R.

    2004-10-01

    The residential oil burner market is currently dominated by the pressure-atomized retention head burner, which has an excellent reputation for reliability and efficiency. In this burner, oil is delivered to a fuel nozzle at pressures from 100 to 150 psi. In addition, to atomizing the fuel, the small, carefully controlled size of the nozzle exit orifice serves to control the burner firing rate. Burners of this type are currently available at firing rates of more than 0.5 gallons-per-hour (70,000 Btu/hr). Nozzles have been made for lower firing rates, but experience has shown that such nozzles suffer rapid fouling of the necessarily small passages, leading to bad spray patterns and poor combustion performance. Also, traditionally burners and the nozzles are oversized to exceed the maximum demand. Typically, this is figured as follows. The heating load of the house on the coldest day for the location is considered to define the maximum heat load. The contractor or installer adds to this to provide a safety margin and for future expansion of the house. If the unit is a boiler that provides domestic hot water through the use of a tankless heating coil, the burner capacity is further increased. On the contrary, for a majority of the time, the heating system is satisfying a much smaller load, as only rarely do all these demands add up. Consequently, the average output of the heating system has to be much less than the design capacity and this is accomplished by start and stop cycling operation of the system so that the time-averaged output equals the demand. However, this has been demonstrated to lead to overall efficiencies lower than the steady-state efficiency. Therefore, the two main reasons for the current practice of using oil burners much larger than necessary for space heating are the unavailability of reliable low firing rate oil burners and the desire to assure adequate input rate for short duration, high draw domestic hot water loads. One approach to solve this problem is to develop a burner, which can operate at two firing rates, with the lower rate being significantly lower than 0.5 gallons per hour. This paper describes the initial results of adopting this approach through a pulsed flow nozzle. It has been shown that the concept of flow modulation with a small solenoid valve is feasible. Especially in the second configuration tested, where the Lee valve was integrated with the nozzle, reasonable modulation in flow of the order of 1.7 could be achieved. For this first prototype, the combustion performance is still not quite satisfactory. Improvements in operation, for example by providing a sharp and positive shut-off so that there is no flow under low pressures with consequent poor atomization could lead to better combustion performance. This could be achieved by using nozzles that have shut off or check valves for example. It is recommended that more work in cooperation with the valve manufacturer could produce a technically viable system. Marketability is of course a far more complex problem to be addressed once a technically viable product is available.

  11. Fire and the Design of Schools 5th ed 

    E-Print Network [OSTI]

    Anonymous

    1975-01-01

    This BULLETIN seeks to give guidance on ways of designing schools so that they will satisfy the requirements of health and safety regulation regarding fire.

  12. Variable firing rate power burner for high efficiency gas furnaces. Final report

    SciTech Connect (OSTI)

    Fuller, H.H.; Demler, R.L.; Poulin, E.

    1980-02-01

    One method for increasing the efficiency of residential furnaces and boilers is to retrofit a burner capable of firing rate (FR) modulation. While maximum FR is still attainable, the average FR is significantly lower, resulting in more effective heat exchanger performance. Equally important is the capability for continuous firing at a very low rate (simmering) which eliminates off-cycle loss, a heavy contributor to inefficiency. Additional performance can be gained by reducing the excess air required by a burner. Based on its previous experience, Foster-Miller Associates, Inc. has designed and tested a low excess air (about 15%) variable firing rate (VFR) burner. The theory of operation and the construction of the test burner are described. Test results are given along with a conclusion/recommendation. A Phase II plan is outlined which suggests methods and steps for fabrication and field testing of a number of prototype units.

  13. Rate Design and Renewables

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantityBonneville Power Administration wouldMassR&D100 Winners * Impacts on GlobalRachel2RateCaseElements Sign In About | Careers

  14. Risk-based design of structures for fire 

    E-Print Network [OSTI]

    Al-Remal, Ahmad Mejbas

    2013-11-28

    Techniques of performance-based design in fire safety have developed notably in the past two decades. One of the reasons for departing from the prescriptive methods is the ability of performance-based methods to form a ...

  15. Applications of Computer Modelling to Fire Safety Design 

    E-Print Network [OSTI]

    Torero, Jose L; Steinhaus, Thomas

    Tools in support of fire safety engineering design have proliferated in the last few years due to the increased performance of computers. These tools are currently being used in a generalized manner in areas such as egress, ...

  16. Flame quality monitor system for fixed firing rate oil burners

    DOE Patents [OSTI]

    Butcher, Thomas A. (Pt. Jefferson, NY); Cerniglia, Philip (Moriches, NY)

    1992-01-01

    A method and apparatus for determining and indicating the flame quality, or efficiency of the air-fuel ratio, in a fixed firing rate heating unit, such as an oil burning furnace, is provided. When the flame brightness falls outside a preset range, the flame quality, or excess air, has changed to the point that the unit should be serviced. The flame quality indicator output is in the form of lights mounted on the front of the unit. A green light indicates that the flame is about in the same condition as when the burner was last serviced. A red light indicates a flame which is either too rich or too lean, and that servicing of the burner is required. At the end of each firing cycle, the flame quality indicator goes into a hold mode which is in effect during the period that the burner remains off. A yellow or amber light indicates that the burner is in the hold mode. In this mode, the flame quality lights indicate the flame condition immediately before the burner turned off. Thus the unit can be viewed when it is off, and the flame condition at the end of the previous firing cycle can be observed.

  17. FIRE Divertor Design March 31, 2004

    E-Print Network [OSTI]

    Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company Balance Assumed · Heating Power: 30 MW · Plasma Gain: 5 · Fusion Power: 150 MW · Alpha Power: 30 MW fusion power, helium must be removed at a rate of 5x1019 particles/sec · Edge density is set to 3x1020 m

  18. FIRE Structural Design Criteria 4/13/01 Revision 0 Page No. i

    E-Print Network [OSTI]

    FIRE Structural Design Criteria 4/13/01 Revision 0 Page No. i FIRE_DesCrit_IZ_041301.doc FIREFIRE (FUSION IGNITION RESEARCH EXPERIMENT) STRUCTURAL DESIGN CRITERIA Rev. 0 4/13/01 I. ZATZ, EDITOR ___________________________ R. Thome #12;FIRE Structural Design Criteria 2/24/99 Revision 0 Page No. 1 INTRODUCTION

  19. The Behaviour and Design of Composite Floor Systems in Fire 

    E-Print Network [OSTI]

    Cameron, Neil

    Modern composite steel frame structures possess a high degree of redundancy. This allows them to survive extreme fires without collapse as there are many alternative loadpaths which can be used to transfer load away from the fire affected part...

  20. PHYSICS DESIGN GUIDELINES FOR ESTIMATING PLASMA PERFORMANCE IN A BURNING PLASMA EXPERIMENT (FIRE)

    E-Print Network [OSTI]

    PHYSICS DESIGN GUIDELINES FOR ESTIMATING PLASMA PERFORMANCE IN A BURNING PLASMA EXPERIMENT (FIRE The physics design guidelines for a next step, high- field tokamak, burning plasma experiment (FIRE, Fusion Ignition Research Experiment) have been developed as an update of the ITER Physics Basis (IPB). The plasma

  1. The integration of Dow's Fire and Explosion Index into process design and optimization to achieve an inherently safer design 

    E-Print Network [OSTI]

    Suardin, Jaffee Arizon

    2006-10-30

    The integration of the safety parameter into process design and optimization is essential. However, there is no previous work in integrating the fire and explosion index (F&EI) into design and optimization. This research proposed a procedure...

  2. North Portal Fuel Storage System Fire Hazard Analysis-ESF Surface Design Package ID

    SciTech Connect (OSTI)

    N.M. Ruonavaara

    1995-01-18

    The purpose of the fire hazard analysis is to comprehensively assess the risk from fire within the individual fire areas. This document will only assess the fire hazard analysis within the Exploratory Studies Facility (ESF) Design Package ID, which includes the fuel storage system area of the North Portal facility, and evaluate whether the following objectives are met: 1.1.1--This analysis, performed in accordance with the requirements of this document, will satisfy the requirements for a fire hazard analysis in accordance with U.S. Department of Energy (DOE) Order 5480.7A. 1.1.2--Ensure that property damage from fire and related perils does not exceed an acceptable level. 1.1.3--Provide input to the ESF Basis For Design (BFD) Document. 1.1.4 Provide input to the facility Safety Analysis Report (SAR) (Paragraph 3.8).

  3. CEE 812 Structural Engineering Seminar Series Advances in the Fire-Resistant Design of Structures

    E-Print Network [OSTI]

    Kamat, Vineet R.

    CEE 812 ­ Structural Engineering Seminar Series Advances in the Fire-Resistant Design of Structures of structures for fire hazards traditionally lies beyond the purview of the structural engineering profession in an increased participation from the structural engineering community, particularly in the development

  4. Fire protection considerations for the design and operation of liquefied petroleum gas (LPG) storage facilities

    SciTech Connect (OSTI)

    Not Available

    1989-01-01

    This standard addresses the design, operation, and maintenance of LPG storage facilities from the standpoint of prevention and control of releases, fire-protection design, and fire-control measures, as well as the history of LPG storage facility failure, facility design philosophy, operating and maintenance procedures, and various fire-protection and firefighting approaches and presentations. The storage facilities covered are LPG installations (storage vessels and associated loading/unloading/transfer systems) at marine and pipeline terminals, natural gas processing plants, refineries, petrochemical plants, and tank farms.

  5. A supply chain network design model for biomass co-firing in coal-fired power plants

    SciTech Connect (OSTI)

    Md. S. Roni; Sandra D. Eksioglu; Erin Searcy; Krishna Jha

    2014-01-01

    We propose a framework for designing the supply chain network for biomass co-firing in coal-fired power plants. This framework is inspired by existing practices with products with similar physical characteristics to biomass. We present a hub-and-spoke supply chain network design model for long-haul delivery of biomass. This model is a mixed integer linear program solved using benders decomposition algorithm. Numerical analysis indicates that 100 million tons of biomass are located within 75 miles from a coal plant and could be delivered at $8.53/dry-ton; 60 million tons of biomass are located beyond 75 miles and could be delivered at $36/dry-ton.

  6. FireWise Construction: Site Design & Building Materials

    E-Print Network [OSTI]

    by the ICC and the three statutory members of the International Code Council: Building Officials and Code-Urban Interface Code #12;About the Authors David Bueche, Ph.D., of Lakewood, Colo., works for Hoover Treated Wood code development, serves on the National Fire Protection Association (NFPA) and American Society

  7. Enhancements in Glovebox Design Resulting from Laboratory-Conducted FIre Tests

    SciTech Connect (OSTI)

    Brooks, Kriston P.; Wunderlich, Gregory M.; Mcentire, James R.; Richmond, William G.

    2013-06-14

    The primary mission of the Pit Disassembly and Conversion Facility (PDCF) Project was to disassemble nuclear weapons pits and convert the resulting special nuclear materials to a form suitable for further disposition. Because of the nature of materials involved, the fundamental system which allowed PDCF to perform its mission was a series of integrated and interconnected gloveboxes which provided confinement and containment of the radioactive materials being processed. The high throughput planned for PDCF and the relatively high neutron and gamma radiation levels of the pits required that gloveboxes be shielded to meet worker dose limits. The glovebox shielding material was required to contain high hydrogen concentrations which typically result in these materials being combustible. High combustible loadings created design challenges for the facility fire suppression and ventilation system design. Combustible loading estimates for the PDCF Plutonium (Pu) Processing Building increased significantly due to these shielding requirements. As a result, the estimates of combustible loading substantially exceeded values used to support fire and facility safety analyses. To ensure a valid basis for combustible loading contributed by the glovebox system, the PDCF Project funded a series of fire tests conducted by the Southwest Research Institute on door panels and a representative glovebox containing Water Extended Polyester (WEP) radiological shielding to observe their behavior during a fire event. Improvements to PDCF glovebox designs were implemented based on lessons learned during the fire test. In particular, methods were developed to provide high levels of neutron shielding while maintaining combustible loading in the glovebox shells at low levels. Additionally, the fire test results led to design modifications to mitigate pressure increases observed during the fire test in order to maintain the integrity of the WEP cladding. These changes resulted in significantly reducing the credited combustible loading of the facility. These advances in glovebox design should be considered for application in nuclear facilities within the Department of Energy complex in the future.

  8. The Design and Development of An Externally Fired Steam Injected Gas Turbine for Cogeneration 

    E-Print Network [OSTI]

    Boyce, M. P.; Meher-Homji, C.; Ford, D.

    1981-01-01

    This paper describes the theoretical background and the design and development of a prototype externally fired steam injected (ECSI) gas turbine which has a potential to utilize lower grade fuels. The system is designed around a 2 shaft 360 HP gas...

  9. Firebot: Design of an Autonomous Fire Fighting Robot Lynette Miller Daniel Rodriguez Kristen Allen Maksim Makeev

    E-Print Network [OSTI]

    Schwartz, Eric M.

    that is designed to find a small fire represented by a light emitting diode in a model home and extinguish it by a cylindrical red object with six red light emitting diodes (LED). The candle can be found in any of the four

  10. Fire Protection Engineering Design Brief Template. Hydrogen Refueling Station.

    SciTech Connect (OSTI)

    LaFleur, Angela Christine; Muna, Alice Baca; Groth, Katrina M.

    2015-08-01

    Building a hydrogen infrastructure system is critical to supporting the development of alternate- fuel vehicles. This report provides a methodology for implementing a performance-based design of an outdoor hydrogen refueling station that does not meet specific prescriptive requirements in NFPA 2, The Hydrogen Technologies Code . Performance-based designs are a code-compliant alternative to meeting prescriptive requirements. Compliance is demonstrated by comparing a prescriptive-based fueling station design with a performance-based design approach using Quantitative Risk Assessment (QRA) methods and hydrogen risk assessment tools. This template utilizes the Sandia-developed QRA tool, Hydrogen Risk Analysis Models (HyRAM), which combines reduced-order deterministic models that characterize hydrogen release and flame behavior with probabilistic risk models to quantify risk values. Each project is unique and this template is not intended to account for site-specific characteristics. Instead, example content and a methodology are provided for a representative hydrogen refueling site which can be built upon for new hydrogen applications.

  11. Emergency relief system design for fire exposure with consideration of multiphase flow

    SciTech Connect (OSTI)

    Forrest, H.S. [ABB Lummus Global Inc., Bloomfield, NJ (United States)

    1995-12-31

    Design methods are presented for deciding whether or not multiphase flow needs to be considered; and if so, for sizing emergency relief systems and estimating the liquid carryover for fire exposure to vessels. The methods apply for fire exposure to both low pressure storage tanks and pressure vessels containing churn-turbulent and bubbly/foamy fluids which do not react exothermically. Design methods are presented for right circular cylindrical vessels, horizontal vessels, spherical vessels and vessel jackets. Design methods are also presented for fluids which decompose endothermically with gaseous decomposition products at temperatures below the boiling point at the relieving pressure. The methods also estimate the amount of additional liquid carryover due to blowdown for oversized relief systems. 11 refs., 1 fig., 2 tabs.

  12. Intraclass Price Elasticity & Electric Rate Design 

    E-Print Network [OSTI]

    Gresham, K. E.

    1987-01-01

    beyond this becomes more elastic as usage increases. In the book "Innovative Electric, Rates," John Chamberlin and Charles Dickson utilize an economic model to test conservation programs. This model utilizes intrac1ass price elasticities and has a.... Utilities must rely on customer data and intuition to estimate customer response to rate changes. These methods have several downfalls. First, the customer data may not reflect customer behavior in an economic downturn. Second, the data may not exactly...

  13. Conceptual design of a coal-fired MHD retrofit. Final technical report

    SciTech Connect (OSTI)

    1994-06-01

    Coal-fired magnetohydrodynamics (MHD) technology is ready for its next level of development - an integrated demonstration at a commercial scale. The development and testing of MHD has shown its potential to be the most efficient, least costly, and cleanest way to burn coal. Test results have verified a greater than 99% removal of sulphur with a potential for greater than 60% efficiency. This development and testing, primarily funded by the U.S. Department of Energy (DOE), has progressed through the completion of its proof-of-concept (POC) phase at the 50 MWt Component Development and Integration Facility (CDIF) and 28 MWt Coal Fired Flow Facility (CFFF), thereby, providing the basis for demonstration and further commercial development and application of the technology. The conceptual design of a retrofit coal-fired MHD generating plant was originally completed by the MHD Development Corporation (MDC) under this Contract, DE-AC22-87PC79669. Thereafter, this concept was updated and changed to a stand-alone MHD demonstration facility and submitted by MDC to DOE in response to the fifth round of solicitations for Clean Coal Technology. Although not selected, that activity represents the major interest in commercialization by the developing industry and the type of demonstration that would be eventually necessary. This report updates the original executive summary of the conceptual design by incorporating the results of the POC program as well as MDC`s proposed Billings MHD Demonstration Project (BMDP) and outlines the steps necessary for commercialization.

  14. Fire Protection

    Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

    2012-12-05

    This Standard was developed to provide acceptable methods and approaches for meeting DOE fire protection program and design requirements and to address special or unique fire protection issues at DOE facilities that are not comprehensively or adequately addressed in national consensus standards or other design criteria.

  15. Behavior of Structures in Fire and Real Design - A Case Study 

    E-Print Network [OSTI]

    Lamont, Susan; Lane, Barbara; Flint, Graeme; Usmani, Asif

    2006-01-01

    A great deal of understanding into the behaviour of composite steel-concrete structures in fire has been developed since the Cardington frame fire tests (UK) 1990s. This has now been broadened so that structures in fire ...

  16. Forest Fire Advanced System Technology (FFAST): A Conceptual Design for Detection and Mapping

    E-Print Network [OSTI]

    is developing a data system to provide near-real-time forest fire information to fire management at the fire of the Technical Staff, Observational Systems Division. California Institute of Technology, Jet Propulsion for the scanner units were difficult to find and in some cases had to be custom built. The Fire Logistics

  17. Indoor air pollution from portable kerosene-fired space heaters. [Effects of wick height and fuel consumption rate

    SciTech Connect (OSTI)

    Traynor, G.W.; Apte, M.G.; Dillworth, J.F.; Grimsrud, D.T.

    1983-02-01

    Indoor use of unvented combustion appliances is known to cause an increase in indoor air pollutant levels. Laboratory tests were conducted on radiant and convective portable kerosene-fired space heaters to identify the pollutants they emit and to determine their emission rates. Laboratory-derived CO and NO/sub 2/ emission rates from unvented portable kerosense-fired space heaters are summarized and the effect of wick height and fuel consumption rate on CO and NO/sub 2/ emissions is given. Pollutant concentration profiles resulting from the use of kerosene heaters in a 27m/sup 3/ environmental chamber and a 240m/sup 3/ house are presented. When such heaters are operated for one hour in a 27m/sup 3/ chamber with 0.4 air changes per hour, the resultant CO/sub 2/ concentrations are well above the U.S. occupational standard, and NO/sub 2/ concentrations are well above California's short-term outdoor standard. Further data on parameters such as heater usage patterns and air exchange rates are needed to determine the actual pollutant exposure that kerosene heater users experience.

  18. Basic Quality Design Standards Rating Scale for Single-case Design 

    E-Print Network [OSTI]

    Boles, Margot

    2015-04-08

    This table is a rating scale for the basic design standards for single-case research adapted from Kratochwill et al.(2010; 2013); and Maggin, Briesch, & Chafouleas (2013).

  19. Performance-based methodology for the fire safe design of insulation materials in energy efficient buildings 

    E-Print Network [OSTI]

    Hidalgo-Medina, Juan P.

    2015-01-01

    quantifiable and acceptable fire safety levels for required energy efficiency targets is established. As a final remark, an application of the performance assessment methodology that introduces fire safety as a quantifiable variable is presented....

  20. Development of software for reliability based design of steel framed structures in fire 

    E-Print Network [OSTI]

    Devaney, Shaun

    2015-06-29

    Fire in building structures represents a risk both to life and property that cannot be fully eliminated. It is the aim of fire safety engineering to reduce this risk to an acceptable level through the application of ...

  1. Standby rate design: current issues and possible innovations

    SciTech Connect (OSTI)

    Goulding, A.J.; Bahceci, Serkan

    2007-05-15

    While options pricing principles have some relevance for the design a standby distribution rates, insurance pricing may provide an even better model. An insurance-based approach using an outage probability methodology also provides powerful incentives to the utility to connect additional DG resources to the grid. (author)

  2. Developing a Fire Danger Rating System for the UK: FireBeaters Phase I final report. Report to the Scottish Wildfire Forum. 

    E-Print Network [OSTI]

    Legg, Colin J; Davies, Gwilym Matthew; Kitchen, Karl; Marno, Penny

    2007-01-01

    Introduction and objectives The objective of this research is to develop a predictive tool for the management of wildfire in the UK and for facilitating good practice by those who work with fire in semi-natural vegetation. ...

  3. A rate design to increase efficiency and reduce revenue requirements

    SciTech Connect (OSTI)

    Boonin, David Magnus

    2009-05-15

    One decoupling approach, a Straight Fixed Variable (SFV) rate design, is a rational way to recover fixed and variable costs because it aligns pricing with variable and fixed cost causation, thereby removing the utility's profit sensitivity to reduced sales. The problem with SFV is that it reduces the variable charge to short-term variable cost, leading to overconsumption. Revenue-neutral energy efficiency ''feebates'' combining fees and rebates offer an economic incentive for consumer energy efficiency. (author)

  4. Feasibility and design of blast mitigation systems for naval applications using water mist fire suppression systems

    E-Print Network [OSTI]

    Kitchenka, Julie A

    2004-01-01

    The recent trend of using fine water mist systems to replace the legacy HALON- 1301 fire suppression systems warrants further study into other applications of the water mist systems. Preliminary research and investigation ...

  5. Control and extinguishment of LPG fires. Final report

    SciTech Connect (OSTI)

    Johnson, D.W.; Martinsen, W.E.; Cavin, W.D.; Chilton, P.D.; Lawson, H.P.; Welker, J.R.

    1980-08-01

    Approximately 100 fire control and fire extinguishment tests were run on free-burning liquefied petroleum gases (LPG) pool fires from 25 ft/sup 2/ to 1600 ft/sup 2/ in area. The LPG was contained in concrete pits, and the pit floors were allowed to cool before the fires were ignited so that the burning rates were not influenced by boiloff from the warm floor. High expansion foam was used for fire control. The foam was applied from fixed generators located on the upwind side of the pit. Fires were controlled after foam application of less than a minute to about 10 minutes, depending on the application rate. Fires were extinguished with dry chemical agents applied through fixed piping systems with tankside nozzles and by manual application using hoselines and portable extinguishers. Fires could readily be extinguished in times ranging from a few seconds to about half a minute, depending on the application rate, system design, and ambient conditions. Additional tests were conducted in 1-ft/sup 2/ and 5-ft/sup 2/ pits to determine the boiloff rates for LPG spilled on concrete, a sand/soil mix, and polyurethane foam substrates. Burning rates for free-burning LPG pool fires from 1 ft/sup 2/ to 1600 ft/sup 2/ in area are also reported.

  6. Control and extinguishment of LPG fires. Final report

    SciTech Connect (OSTI)

    Not Available

    1980-06-01

    Approximately 100 fire control and fire extinguishment tests were run on free-burning LPG pool fires from 25 ft/sup 2/ to 1600 ft/sup 2/ in area. The LPG was contained in concrete pits, and the pit floors were allowed to cool before the fires were ignited so that the burning rates were not influenced by boiloff from the warm floor. High expansion foam was used for fire control. The foam was applied from fixed generators located on the upwind side of the pit. Fires were controlled after foam application of less than a minute to about 10 minutes, depending on the application rate. Fires were extinguished with dry chemical agents applied through fixed piping systems with tankside nozzles and by manual application using hoselines and portable extinguishers. Fires could readily be extinguished in times ranging from a few seconds to about half a minute, depending on the application rate, system design, and ambient conditions. Additional tests were conducted in 1-ft/sup 2/ and 5-ft/sup 2/ pits to determine the boiloff rates for LPG spilled on concrete, a sand/soil mix, and polyurethane foam substrates. Burning rates for free-burning LPG pool fires from 1 ft/sup 2/ to 1600 ft/sup 2/ in area are also reported.

  7. Fire Danger Fact Sheet The most commonly accepted definition of fire danger is "the resultant descriptor of

    E-Print Network [OSTI]

    Fire Danger Fact Sheet The most commonly accepted definition of fire danger is "the resultant are combined to assess the daily fire potential on an area. Fire danger is usually expressed in numeric. The fire danger rating of an area gives the fire manager a tool to help with the day-to-day "fire business

  8. Fire hazard analysis of Rocky Flats Building 776/777 duct systems

    SciTech Connect (OSTI)

    DiNenno, P.J.; Scheffey, J.L.; Gewain, R.G.; Shanley, J.H. Jr.

    1988-12-01

    The objective of this analysis is to determine if ventilation ductwork in Building 776/777 will maintain their structural integrity during expected fire conditions as well as standard design fires typically used to ascertain fire resistance ratings. If the analysis shows that ductwork will not maintain structural integrity, the impact of this failure will be determined and analyzed, and alternative solutions recommended. Associated with this analysis is the development of a computer fire model which can be used as an engineering tool in analyzing the effect of fires on ductwork in other areas and buildings.

  9. Risk and Performance Based Fire Safety Design of Steel and Composite Structures 

    E-Print Network [OSTI]

    Lange, David

    2009-01-01

    For the development of performance based design on a proper scientific basis the use of the concept of risk is inevitable. However, the application of this concept to actual structural design is not simple because of the ...

  10. Descriptive Quality Indicators Rating Scale for Single-case Design 

    E-Print Network [OSTI]

    Boles, Margot

    2015-04-08

    This table presents a rating scale for descriptive quality indicators in single-case research. This table is adapted from CEC (2014), Horner et al. (2005), and Reichow (2008)

  11. Customer Incentives for Energy Efficiency Through Electric and Natural Gas Rate Design

    SciTech Connect (OSTI)

    none,

    2009-09-01

    Summarizes the issues and approaches involved in motivating customers to reduce the total energy they consume through energy prices and rate design.

  12. HOUSEHOLD AND STRUCTURAL INSECTS Effect of Trap Design, Chemical Lure, Carbon Dioxide Release Rate,

    E-Print Network [OSTI]

    Wang, Changlu

    HOUSEHOLD AND STRUCTURAL INSECTS Effect of Trap Design, Chemical Lure, Carbon Dioxide Release Rate passive monitor available in the market for bed bugs

  13. The Impact of Rate Design and Net Metering on the Bill Savings...

    Open Energy Info (EERE)

    The Impact of Rate Design and Net Metering on the Bill Savings from Distributed Photovoltaics (PV) for Residential Customers in California Jump to: navigation, search Tool Summary...

  14. Fire Woman

    E-Print Network [OSTI]

    Anderson, Keisha-Gaye

    2012-01-01

    at www.keishagaye.com Anderson, K-G. “Fire Woman”. http://20: 156-160 ISSN: 2159-2926 Fire Woman Keisha-Gaye AndersonAnderson, K-G. “Fire Woman”. http://escholarship.org/uc/

  15. Synthetic aperture design for increased SAR image rate

    DOE Patents [OSTI]

    Bielek, Timothy P. (Albuquerque, NM); Thompson, Douglas G. (Albuqerque, NM); Walker, Bruce C. (Albuquerque, NM)

    2009-03-03

    High resolution SAR images of a target scene at near video rates can be produced by using overlapped, but nevertheless, full-size synthetic apertures. The SAR images, which respectively correspond to the apertures, can be analyzed in sequence to permit detection of movement in the target scene.

  16. Fire Alarm Pull Fire Alarm Pull Fire Alarm Pull

    E-Print Network [OSTI]

    California at Santa Barbara, University of

    .39 1610A MECH 267.14 MECH 42.16 1727 CIRC 40.84 Fire Alarm Pull Fire Alarm Pull Fire Alarm Pull Fire Alarm Pull Fire Alarm Pull Fire Alarm Pull Fire Alarm Pull Fire Alarm Pull DN. UP. STAIRS 136.84 SHAFT 2 50.09 1821 ELEV 50.09 Fire Extinguisher Fire Extinguisher Fire Extinguisher Fire Extinguisher North

  17. Design considerations and operating experience in firing refuse derived fuel in a circulating fluidized bed combustor

    SciTech Connect (OSTI)

    Piekos, S.J.; Matuny, M.

    1997-12-31

    The worldwide demand for cleaner, more efficient methods to dispose of municipal solid waste has stimulated interest in processing solid waste to produce refuse derived fuel (RDF) for use in circulating fluidized bed (CFB) boilers. The combination of waste processing and materials recovery systems and CFB boiler technology provides the greatest recovery of useful resources from trash and uses the cleanest combustion technology available today to generate power. Foster Wheeler Power Systems along with Foster Wheeler Energy Corporation and several other Foster Wheeler sister companies designed, built, and now operates a 1600 tons per day (TPD) (1450 metric tons) municipal waste-to-energy project located in Robbins, Illinois, a suburb of Chicago. This project incorporates waste processing systems to recover recyclable materials and produce RDF. It is the first project in the United States to use CFB boiler technology to combust RDF. This paper will provide an overview of the Robbins, Illinois waste-to-energy project and will examine the technical and environmental reasons for selecting RDF waste processing and CFB combustion technology. Additionally, this paper will present experience with handling and combusting RDF and review the special design features incorporated into the CFB boiler and waste processing system that make it work.

  18. Firing of pulverized solvent refined coal

    DOE Patents [OSTI]

    Derbidge, T. Craig (Sunnyvale, CA); Mulholland, James A. (Chapel Hill, NC); Foster, Edward P. (Macungie, PA)

    1986-01-01

    An air-purged burner for the firing of pulverized solvent refined coal is constructed and operated such that the solvent refined coal can be fired without the coking thereof on the burner components. The air-purged burner is designed for the firing of pulverized solvent refined coal in a tangentially fired boiler.

  19. A comparison of techniques for on-line monitoring of unit heat rate of coal fired units

    SciTech Connect (OSTI)

    Sarunac, N.; Levy, E. (Lehigh Univ., Bethlehem, PA (USA). Energy Research Center); Williams, S.; Cramer, D. (Potomac Electric Power Co. (US)); Leyse, R. (Electric Power Research Inst., Palo Alto, CA (USA))

    1990-01-01

    The input/output method is one of the most commonly used approaches for measuring unit performance, but it is rarely used on-line because of difficulties in accurate on-line measurement of coal heating value and flow rate. Two other techniques for monitoring unit heat rate are much more suitable for on-line application. One of these, the boiler turbine cycle efficiency. The output/loss method utilizes information on turbine cycle performance along with measurements of stack gas flow rate, unburned carbon and other commonly available information such as O{sub 2} levels, gas and air temperatures and gross and auxiliary power. This paper provides a summary of the three techniques, describes their characteristics, gives instrumentation requirements and compares accuracies. Guidelines on the applications for which each technique should be considered are also given.

  20. Impact of Rate Design Alternatives on Residential Solar Customer Bills. Increased Fixed Charges, Minimum Bills and Demand-based Rates

    SciTech Connect (OSTI)

    Bird, Lori; Davidson, Carolyn; McLaren, Joyce; Miller, John

    2015-09-01

    With rapid growth in energy efficiency and distributed generation, electric utilities are anticipating stagnant or decreasing electricity sales, particularly in the residential sector. Utilities are increasingly considering alternative rates structures that are designed to recover fixed costs from residential solar photovoltaic (PV) customers with low net electricity consumption. Proposed structures have included fixed charge increases, minimum bills, and increasingly, demand rates - for net metered customers and all customers. This study examines the electricity bill implications of various residential rate alternatives for multiple locations within the United States. For the locations analyzed, the results suggest that residential PV customers offset, on average, between 60% and 99% of their annual load. However, roughly 65% of a typical customer's electricity demand is non-coincidental with PV generation, so the typical PV customer is generally highly reliant on the grid for pooling services.

  1. Rethinking Standby & Fixed Cost Charges: Regulatory & Rate Design Pathways to Deeper Solar PV Cost Reductions

    Broader source: Energy.gov [DOE]

    While solar PV's impact on utilities has been frequently discussed the past year, little attention has been paid to the potentially impact posed by solar PV-specific rate designs (often informally referred to as solar "fees" or "taxes") upon non-hardware "soft" cost reductions. In fact, applying some rate designs to solar PV customers could potentially have a large impact on the economics of PV systems.

  2. Design consistency and driver error as reflected by driver workload and accident rates 

    E-Print Network [OSTI]

    Wooldridge, Mark Douglas

    1992-01-01

    DESIGN CONSISTENCY AND DRIVER ERROR AS REFLECTED BY DRIVER WORKLOAD AND ACCIDENT RATES A Thesis by MARK DOUGLAS WOOLDRIDGE Approved as to style and content by: Daniel B. Fambro (Chair of Committee) Raymond A. Krammes (Member) Olga J.... Pendleton (Member) James T. P. Yao (Head of Department) May 1992 ABSTRACT Design Consistency and Driver Error as Reflected by Driver Workload and Accident Rates (May 1992) Mark Douglas Wooldridge, B. S. , Texas A&M University Chair of Advisory...

  3. RATES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    and PACI Final FRN for Rate Order No. WAPA-139 - Notice of Order Temporarily Extending Formula Rates for Power, Transmission and Ancillary Services (PDF - 49K) Final FRN for Rate...

  4. RATES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    - 392K) Final FRN for Rate Order No. WAPA-139 - Notice of Order Temporarily Extending Formula Rates for Power, Transmission and Ancillary Services (PDF - 49K) Final FRN for Rate...

  5. The Phoenix series large scale LNG pool fire experiments.

    SciTech Connect (OSTI)

    Simpson, Richard B.; Jensen, Richard Pearson; Demosthenous, Byron; Luketa, Anay Josephine; Ricks, Allen Joseph; Hightower, Marion Michael; Blanchat, Thomas K.; Helmick, Paul H.; Tieszen, Sheldon Robert; Deola, Regina Anne; Mercier, Jeffrey Alan; Suo-Anttila, Jill Marie; Miller, Timothy J.

    2010-12-01

    The increasing demand for natural gas could increase the number and frequency of Liquefied Natural Gas (LNG) tanker deliveries to ports across the United States. Because of the increasing number of shipments and the number of possible new facilities, concerns about the potential safety of the public and property from an accidental, and even more importantly intentional spills, have increased. While improvements have been made over the past decade in assessing hazards from LNG spills, the existing experimental data is much smaller in size and scale than many postulated large accidental and intentional spills. Since the physics and hazards from a fire change with fire size, there are concerns about the adequacy of current hazard prediction techniques for large LNG spills and fires. To address these concerns, Congress funded the Department of Energy (DOE) in 2008 to conduct a series of laboratory and large-scale LNG pool fire experiments at Sandia National Laboratories (Sandia) in Albuquerque, New Mexico. This report presents the test data and results of both sets of fire experiments. A series of five reduced-scale (gas burner) tests (yielding 27 sets of data) were conducted in 2007 and 2008 at Sandia's Thermal Test Complex (TTC) to assess flame height to fire diameter ratios as a function of nondimensional heat release rates for extrapolation to large-scale LNG fires. The large-scale LNG pool fire experiments were conducted in a 120 m diameter pond specially designed and constructed in Sandia's Area III large-scale test complex. Two fire tests of LNG spills of 21 and 81 m in diameter were conducted in 2009 to improve the understanding of flame height, smoke production, and burn rate and therefore the physics and hazards of large LNG spills and fires.

  6. Public Utility Regulatory Policies Act of 1978: Natural Gas Rate Design Study

    SciTech Connect (OSTI)

    None

    1980-05-01

    First, the comments on May 3, 1979 Notice of Inquiry of DOE relating to the Gas Utility Rate Design Study Required by Section 306 of PURPA are presented. Then, comments on the following are included: (1) ICF Gas Utility Model, Gas Utility Model Data Outputs, Scenario Design; (2) Interim Model Development Report with Example Case Illustrations; (3) Interim Report on Simulation of Seven Rate Forms; (4) Methodology for Assessing the Impacts of Alternative Rate Designs on Industrial Energy Use; (5) Simulation of Marginal-Cost-Based Natural Gas Rates; and (6) Preliminary Discussion Draft of the Gas Rate Design Study. Among the most frequent comments expressed were the following: (a) the public should be given the opportunity to review the final report prior to its submission to Congress; (b) results based on a single computer model of only four hypothetical utility situations cannot be used for policy-making purposes for individual companies or the entire gas industry; (c) there has been an unobjective treatment of traditional and economic cost rate structures; the practical difficulties and potential detrimental consequences of economic cost rates are not fully disclosed; and (d) it is erroneous to assume that end users, particularly residential customers, are influenced by price signals in the rate structure, as opposed to the total bill.

  7. Calculation of Fire Severity Factors and Fire Non-Suppression Probabilities For A DOE Facility Fire PRA

    SciTech Connect (OSTI)

    Tom Elicson; Bentley Harwood; Jim Bouchard; Heather Lucek

    2011-03-01

    Over a 12 month period, a fire PRA was developed for a DOE facility using the NUREG/CR-6850 EPRI/NRC fire PRA methodology. The fire PRA modeling included calculation of fire severity factors (SFs) and fire non-suppression probabilities (PNS) for each safe shutdown (SSD) component considered in the fire PRA model. The SFs were developed by performing detailed fire modeling through a combination of CFAST fire zone model calculations and Latin Hypercube Sampling (LHS). Component damage times and automatic fire suppression system actuation times calculated in the CFAST LHS analyses were then input to a time-dependent model of fire non-suppression probability. The fire non-suppression probability model is based on the modeling approach outlined in NUREG/CR-6850 and is supplemented with plant specific data. This paper presents the methodology used in the DOE facility fire PRA for modeling fire-induced SSD component failures and includes discussions of modeling techniques for: • Development of time-dependent fire heat release rate profiles (required as input to CFAST), • Calculation of fire severity factors based on CFAST detailed fire modeling, and • Calculation of fire non-suppression probabilities.

  8. Conceptual design assessment for the co-firing of bio-refinery supplied lignin project. Quarterly report, June 23--July 1, 2000

    SciTech Connect (OSTI)

    Berglund, T.; Ranney, J.T.; Babb, C.L.

    2000-07-27

    The Conceptual Design Assessment for the Co-Firing of Bio-Refinery Supplied Lignin Project was successfully kicked off on July 23, 2000 during a meeting at the TVA-PPI facility in Muscle Shoals, AL. An initial timeline for the study was distributed, issues of concern were identified and a priority actions list was developed. Next steps include meeting with NETL to discuss de-watering and lignin fuel testing, the development of the mass balance model and ethanol facility design criteria, providing TVA-Colbert with preliminary lignin fuel analysis and the procurement of representative feed materials for the pilot and bench scale testing of the hydrolysis process.

  9. Engineering development of advanced coal-fired low-emissions boiler system. Phase II subsystem test design and plan - an addendum to the Phase II RD & T Plan

    SciTech Connect (OSTI)

    NONE

    1995-05-01

    Shortly after the year 2000 it is expected that new generating plants will be needed to meet the growing demand for electricity and to replace the aging plants that are nearing the end of their useful service life. The plants of the future will need to be extremely clean, highly efficient and economical. Continuing concerns over acid rain, air toxics, global climate changes, ozone depletion and solid waste disposal are expected to further then regulations. In the late 1980`s it was commonly believed that coal-fired power plants of the future would incorporate either some form of Integrated Gasification Combined Cycle (IGCC) or first generation Pressurized Fluidized Bed Combustion (PFBS) technologies. However, recent advances In emission control techniques at reduced costs and auxiliary power requirements coupled with significant improvements In steam turbine and cycle design have clearly indicated that pulverized coal technology can continue to be competitive In both cost and performance. In recognition of the competitive potential for advanced pulverized coal-fired systems with other emerging advanced coal-fired technologies, DOE`s Pittsburgh Energy Technology Center (PETC) began a research and development initiative In late 1990 named, Combustion 2000, with the intention of preserving and expanding coal as a principal fuel In the Generation of electrical power. The project was designed for two stages of commercialization, the nearer-term Low Emission Boiler System (LEBS) program, and for the future, the High Performance Power System (HIPPS) program. B&W is participating In the LEBS program.

  10. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    E-Print Network [OSTI]

    Darghouth, Naim Richard

    2013-01-01

    electricity markets: Need and design. Utilities Policy 16,market design .Alternative wholesale market design and retail rate

  11. FIRE SYSTEMS Professional Organizations

    E-Print Network [OSTI]

    Acton, Scott

    FIRE SYSTEMS Professional Organizations: American Fire Sprinkler Association (AFSA) Society for Fire Protection Engineers (SFPE) National Fire Protection Agency (NFPA) Events & Training: UVa Center for Leadership Excellence classes SkillSoft classes American Fire Sprinkler Association events American Fire

  12. RATES

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    - Washoe Project, Stampede Division FERC Order Approving Extension of Non-Firm Power Formula Rate - Rate Order No. WAPA-160 (Sept. 5, 2013) (PDF - 22K) Notice of Extension of...

  13. Fire and the Compartmentation of Buildings 

    E-Print Network [OSTI]

    McGuire, J

    No building is free from the threat of fire. A designer, however, can ensure that only limited damage will result if fire breaks out by reducing the over-all fire risk. There are various means at his disposal, but the single design feature...

  14. Vacuum Bellows, Vacuum Piping, Cryogenic Break, and Copper Joint Failure Rate Estimates for ITER Design Use

    SciTech Connect (OSTI)

    L. C. Cadwallader

    2010-06-01

    The ITER international project design teams are working to produce an engineering design in preparation for construction of the International Thermonuclear Experimental Reactor (ITER) tokamak. During the course of this work, questions have arisen in regard to safety barriers and equipment reliability as important facets of system design. The vacuum system designers have asked several questions about the reliability of vacuum bellows and vacuum piping. The vessel design team has asked about the reliability of electrical breaks and copper-copper joints used in cryogenic piping. Research into operating experiences of similar equipment has been performed to determine representative failure rates for these components. The following chapters give the research results and the findings for vacuum system bellows, power plant stainless steel piping (amended to represent vacuum system piping), cryogenic system electrical insulating breaks, and copper joints.

  15. Fire Paradigms Spring, 2015

    E-Print Network [OSTI]

    Hill, Jeffrey E.

    ;Potential approaches include: Paleoecology/ fire history Fire behavior and ecology modeling Meteorology

  16. KUIPER BELT OBJECT OCCULTATIONS: EXPECTED RATES, FALSE POSITIVES, AND SURVEY DESIGN

    SciTech Connect (OSTI)

    Bickerton, S. J. [Department of Astrophysical Sciences, Princeton University, Princeton, NJ 08544 (United States); Welch, D. L. [Department of Physics and Astronomy, McMaster University, Hamilton, ON L8S 4M1 (Canada); Kavelaars, J. J. [Herzberg Institute of Astrophysics, Victoria, BC V9E 2E7 (Canada)], E-mail: bick@astro.princeton.edu, E-mail: welch@physics.mcmaster.ca, E-mail: JJ.Kavelaars@nrc-cnrc.gc.ca

    2009-05-15

    A novel method of generating artificial scintillation noise is developed and used to evaluate occultation rates and false positive rates for surveys probing the Kuiper Belt with the method of serendipitous stellar occultations. A thorough examination of survey design shows that (1) diffraction-dominated occultations are critically (Nyquist) sampled at a rate of 2 Fsu{sup -1}, corresponding to 40 s{sup -1} for objects at 40 AU, (2) occultation detection rates are maximized when targets are observed at solar opposition, (3) Main Belt asteroids will produce occultations light curves identical to those of Kuiper Belt Objects (KBOs) if target stars are observed at solar elongations of: 116{sup 0} {approx}< {epsilon} {approx}< 125 deg., or 131 deg. {approx}< {epsilon} {approx}< 141 deg., and (4) genuine KBO occultations are likely to be so rare that a detection threshold of {approx}>7-8{sigma} should be adopted to ensure that viable candidate events can be disentangled from false positives.

  17. Advanced Turbine Systems Program conceptual design and product development. Task 3.0, Selection of natural gas-fired Advanced Turbine System

    SciTech Connect (OSTI)

    1994-12-01

    This report presents results of Task 3 of the Westinghouse ATS Phase II program. Objective of Task 3 was to analyze and evaluate different cycles for the natural gas-fired Advanced Turbine Systems in order to select one that would achieve all ATS program goals. About 50 cycles (5 main types) were evaluated on basis of plant efficiency, emissions, cost of electricity, reliability-availability-maintainability (RAM), and program schedule requirements. The advanced combined cycle was selected for the ATS plant; it will incorporate an advanced gas turbine engine as well as improvements in the bottoming cycle and generator. Cost and RAM analyses were carried out on 6 selected cycle configurations and compared to the baseline plant. Issues critical to the Advanced Combined Cycle are discussed; achievement of plant efficiency and cost of electricity goals will require higher firing temperatures and minimized cooling of hot end components, necessitating new aloys/materials/coatings. Studies will be required in combustion, aerodynamic design, cooling design, leakage control, etc.

  18. In-Vessel Coil Material Failure Rate Estimates for ITER Design Use

    SciTech Connect (OSTI)

    L. C. Cadwallader

    2013-01-01

    The ITER international project design teams are working to produce an engineering design for construction of this large tokamak fusion experiment. One of the design issues is ensuring proper control of the fusion plasma. In-vessel magnet coils may be needed for plasma control, especially the control of edge localized modes (ELMs) and plasma vertical stabilization (VS). These coils will be lifetime components that reside inside the ITER vacuum vessel behind the blanket modules. As such, their reliability is an important design issue since access will be time consuming if any type of repair were necessary. The following chapters give the research results and estimates of failure rates for the coil conductor and jacket materials to be used for the in-vessel coils. Copper and CuCrZr conductors, and stainless steel and Inconel jackets are examined.

  19. Doctoral Defense "Structural reliability assessment under fire"

    E-Print Network [OSTI]

    Kamat, Vineet R.

    Doctoral Defense "Structural reliability assessment under fire" Qianru Guo Date: December 11, 2014 Engineering Structural safety under fire has received significant attention in recent years. Current approaches to structural fire design are based on prescriptive codes that emphasize insulation of steel

  20. Fire safety of LPG in marine transportation

    SciTech Connect (OSTI)

    Martinsen, W.E.; Johnson, D.W.; Welker, J.R.

    1980-08-01

    This report contains an analytical examination of cargo spill and fire hazard potential associated with the marine handling of liquefied petroleum gas (LPG) as cargo. Principal emphasis was on cargo transfer operations for ships unloading at receiving terminals, and barges loading or unloading at a terminal. Major safety systems, including emergency shutdown systems, hazard detection systems, and fire extinguishment and control systems were included in the analysis. Spill probabilities were obtained from fault tree analyses utilizing composite LPG tank ship and barge designs. Failure rates for hardware in the analyses were generally taken from historical data on similar generic classes of hardware, there being very little historical data on the specific items involved. Potential consequences of cargo spills of various sizes are discussed and compared to actual LPG vapor cloud incidents. The usefulness of hazard mitigation systems (particularly dry chemical fire extinguishers and water spray systems) in controlling the hazards posed by LPG spills and spill fires is also discussed. The analysis estimates the probability of fatality for a terminal operator is about 10/sup -6/ to 10/sup -5/ per cargo transfer operation. The probability of fatality for the general public is substantially less.

  1. Fire Protection 

    E-Print Network [OSTI]

    Bird, Eric L.; Studd, S. D.

    1958-11-25

    The first object of fire protection is to ensure safety of life; the second is to preserve from damage, resulting from the occasional outbreak, the activities (or occupancies) housed in buildings. Occupancies are usually ...

  2. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    E-Print Network [OSTI]

    Darghouth, Naim Richard

    2013-01-01

    Borenstein, S. , 2007. Electricity Rate Structures and theEnvironmentally-Sound Electricity Rates for the Twenty-FirstCap-and-Trade for Electricity Rate Design, with Examples

  3. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    E-Print Network [OSTI]

    Darghouth, Naim Richard

    2013-01-01

    scenarios .. 85 4.2.2 Wholesale market design .electricity market scenarios, retail rate designs, PVscenario). Results: Alternative wholesale market design and

  4. Phasic Firing Time Locked to Cocaine Self-Infusion and Locomotion: Dissociable Firing Patterns of Single Nucleus

    E-Print Network [OSTI]

    West, Mark O.

    Phasic Firing Time Locked to Cocaine Self-Infusion and Locomotion: Dissociable Firing Patterns-administration sessions (0.7 mg/kg per infusion, fixed ratio 1). We reported previously that NAcc neurons showed a change in firing occurs during the interval that elapses between successive cocaine self-infusions. Firing rate

  5. THERMAL DESIGN METHODOLOGY FOR LOW FLOW RATE SINGLE-PHASE AND TWO-PHASE MICRO-CHANNEL HEAT SINKS

    E-Print Network [OSTI]

    Qu, Weilin

    THERMAL DESIGN METHODOLOGY FOR LOW FLOW RATE SINGLE-PHASE AND TWO-PHASE MICRO-CHANNEL HEAT SINKS-phase micro- channel heat sinks under a fixed liquid coolant flow rate. The parameters relevant to heat sink-channel dimensions corresponding to the prescribed dissipative heat flux and liquid coolant flow rate. Heat sink

  6. Advanced turbine systems program conceptual design and product development task 5 -- market study of the gas fired ATS. Topical report

    SciTech Connect (OSTI)

    1995-05-01

    Solar Turbines Incorporated (Solar), in partnership with the Department of Energy, will develop a family of advanced gas turbine-based power systems (ATS) for widespread commercialization within the domestic and international industrial marketplace, and to the rapidly changing electric power generation industry. The objective of the jointly-funded Program is to introduce an ATS with high efficiency, and markedly reduced emissions levels, in high numbers as rapidly as possible following introduction. This Topical Report is submitted in response to the requirements outlined in Task 5 of the Department of Energy METC Contract on Advanced Combustion Systems, Contract No, DE AC21-93MC30246 (Contract), for a Market Study of the Gas Fired Advanced Turbine System. It presents a market study for the ATS proposed by Solar, and will examine both the economic and siting constraints of the ATS compared with competing systems in the various candidate markets. Also contained within this report is an examination and analysis of Solar`s ATS and its ability to compete in future utility and industrial markets, as well as factors affecting the marketability of the ATS.

  7. Fire Classifications Fires involving the ordinary

    E-Print Network [OSTI]

    Jia, Songtao

    , plastics, etc. Fires involving combustible or flammable liquids such as gasoline, kerosene, oils, grease to prevent fires. Personnel should neither create nor tolerate conditions that could cause or fuel a fire is protected by various devices such as smoke detectors, sprinkler systems, and manual fire alarm pull stations

  8. Computational Fluid Dynamics (CFD) Modelling on Soot Yield for Fire

    E-Print Network [OSTI]

    Computational Fluid Dynamics (CFD) Modelling on Soot Yield for Fire Engineering Assessment Yong S (CFD) Modelling is now widely used by fire safety engineers throughout the world as a tool of the smoke control design as part of the performance based fire safety design in the current industry

  9. Wireless Information and Power Transfer: Architecture Design and Rate-Energy Tradeoff

    E-Print Network [OSTI]

    Zhou, Xun; Ho, Chin Keong

    2012-01-01

    Simultaneous information and power transfer over the wireless channels potentially offers great convenience to mobile users. Yet practical receiver designs impose technical constraints on its hardware realization, as practical circuits for harvesting energy from radio signals are not yet able to decode the carried information directly. To make theoretical progress, we propose a general receiver operation, namely, dynamic power splitting (DPS), which splits the received signal with adjustable power for energy harvesting and for information decoding. Moreover, we propose two types of practical receiver architectures, namely, separated versus integrated information and energy receivers. The integrated receiver integrates the front-end components of the separated receiver, thus achieving a smaller form factor. The rateenergy tradeoff for these two architectures are characterized by a so-called rate-energy (R-E) region. Numerical results show that the R-E region of the integrated receiver is superior to that of th...

  10. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    E-Print Network [OSTI]

    Darghouth, Naim Richard

    2013-01-01

    linking wholesale and retail market conditions, and providesbetween wholesale markets, retail electricity rates, andof Electricity Market Conditions, Retail Rate Design, and

  11. The Assessment and Response of Concrete Structures Subject to Fire 

    E-Print Network [OSTI]

    Law, Angus

    2010-01-01

    Over the last 20 to 30 years, the field of structural fire design has shifted from relying on single element fire resistance testing to the consideration of the effects of full-frame behaviour. The change has been driven ...

  12. Model Fire Protection Program

    Broader source: Energy.gov [DOE]

    To facilitate conformance with its fire safety directives and the implementation of a comprehensive fire protection program, DOE has developed a number of "model" program documents. These include a comprehensive model fire protection program, model fire hazards analyses and assessments, fire protection system inspection and testing procedures, and related material.

  13. Fire suppressing apparatus. [sodium fires

    DOE Patents [OSTI]

    Buttrey, K.E.

    1980-12-19

    Apparatus for smothering a liquid sodium fire comprises a pan, a perforated cover on the pan, and tubed depending from the cover and providing communication between the interior of the pan and the ambient atmosphere through the perforations in the cover. Liquid caught in the pan rises above the lower ends of the tubes and thus serves as a barrier which limits the amount of air entering the pan.

  14. Fire: A Constructive Prescription

    E-Print Network [OSTI]

    Sadighian, Michael

    2012-01-01

    O. (2009). The Central Role of Fire. California Indians andsmall, frequent, low-severity fires to foster these mosaicsR.E. , Sapsis, D.B. 1992. Fires as agents of bio- diversity:

  15. Smoldering - The Fire Scenario 

    E-Print Network [OSTI]

    Torero, Jose L

    2000-01-01

    There are certain fire initiation scenarios that are particularly common, one of great significance is a fire initiated from the ignition of a porous fuel. Nearly 40% of the deaths due to fire can be traced to cigarette induced ...

  16. Sandia Energy - Fire Science

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    Fire Science Home Stationary Power Nuclear Fuel Cycle Nuclear Energy Safety Technologies Risk and Safety Assessment Fire Science Fire ScienceTara Camacho-Lopez2015-05-11T17:01:52+0...

  17. Computational modeling of composite material fires.

    SciTech Connect (OSTI)

    Brown, Alexander L.; Erickson, Kenneth L.; Hubbard, Joshua Allen; Dodd, Amanda B.

    2010-10-01

    Composite materials behave differently from conventional fuel sources and have the potential to smolder and burn for extended time periods. As the amount of composite materials on modern aircraft continues to increase, understanding the response of composites in fire environments becomes increasingly important. An effort is ongoing to enhance the capability to simulate composite material response in fires including the decomposition of the composite and the interaction with a fire. To adequately model composite material in a fire, two physical model development tasks are necessary; first, the decomposition model for the composite material and second, the interaction with a fire. A porous media approach for the decomposition model including a time dependent formulation with the effects of heat, mass, species, and momentum transfer of the porous solid and gas phase is being implemented in an engineering code, ARIA. ARIA is a Sandia National Laboratories multiphysics code including a range of capabilities such as incompressible Navier-Stokes equations, energy transport equations, species transport equations, non-Newtonian fluid rheology, linear elastic solid mechanics, and electro-statics. To simulate the fire, FUEGO, also a Sandia National Laboratories code, is coupled to ARIA. FUEGO represents the turbulent, buoyantly driven incompressible flow, heat transfer, mass transfer, and combustion. FUEGO and ARIA are uniquely able to solve this problem because they were designed using a common architecture (SIERRA) that enhances multiphysics coupling and both codes are capable of massively parallel calculations, enhancing performance. The decomposition reaction model is developed from small scale experimental data including thermogravimetric analysis (TGA) and Differential Scanning Calorimetry (DSC) in both nitrogen and air for a range of heating rates and from available data in the literature. The response of the composite material subject to a radiant heat flux boundary condition is examined to study the propagation of decomposition fronts of the epoxy and carbon fiber and their dependence on the ambient conditions such as oxygen concentration, surface flow velocity, and radiant heat flux. In addition to the computational effort, small scaled experimental efforts to attain adequate data used to validate model predictions is ongoing. The goal of this paper is to demonstrate the progress of the capability for a typical composite material and emphasize the path forward.

  18. Design and performance requirements for a fluidized bed boiler firing municipal refuse derived fuel in Ravenna, Italy

    SciTech Connect (OSTI)

    Murphy, M.L.

    1999-07-01

    In early 1998, the City of Ravenna, Italy, commissioned a fluid bed boiler/waste-to-energy system to combust approximately 50,000 tonnes per year of processed municipal waste and generate electrical power. Much of the fuel preparation and processing equipment was already in place and the primary focus of this project was to implement an environmentally acceptable energy conversion process compatible with the 6.0 tonnes/hr of fuel being processed. The fluid bed boiler system being provided will incorporate state of the art environmental controls for abatement of all pollutants, including products of incomplete combustion (PICs), NO{sub x}, acid gases, and particulates. The project will deliver an average of 70,000 pounds per hour of steam to generate approximately 7 MW of electricity. The following is a description of the process and equipment being utilized for the energy conversion and boiler island, including the environmental abatement equipment. Design specifications for the plant including fuel and emission limits are presented herein. The facility is scheduled for startup in mid-1999.

  19. Elevated Temperature Materials for Power Generation and Propulsion The energy industry is designing higher-efficiency land-based turbines for natural gas-fired

    E-Print Network [OSTI]

    Nair, Sankar

    higher-efficiency land-based turbines for natural gas-fired power generation systems. The high inlet is significant for modeling cyclic deformation in directionally solidified and single crystal turbine blades

  20. Fire Safety Training: Fire Modeling- NUREG 1934

    Office of Energy Efficiency and Renewable Energy (EERE)

    Presenter: Frederick W. Mowrer, Ph.D., P.E. Director Fire Protection Engineering Programs - Cal Poly – SLO

  1. Large-scale pool fires 

    E-Print Network [OSTI]

    Steinhaus, Thomas; Welch, Stephen; Carvel, Ricky O; Torero, Jose L

    2007-03-29

    A review of research into the burning behaviour of large pool fires and fuel spill fires is presented. The features which distinguish such fires from smaller pool fires are mainly associated with the fire dynamics at low ...

  2. Design Studies for a High-Repetition-Rate FEL Facility at LBNL.

    E-Print Network [OSTI]

    CORLETT, J.

    2009-01-01

    for a High-Repetition-Rate FEL Facility at LBNL* A. Brepetition-rate, seeded FEL. Figure 2: Longitudinal phase-spontaneous emission FEL with energy-chirped electron beam

  3. Design and Feasibility Assessment of a Retrospective Epidemiological Study of Coal-Fired Power Plant Emissions in the Pittsburgh Pennsylvania Region

    SciTech Connect (OSTI)

    Richard A. Bilonick; Daniel Connell; Evelyn Talbott; Jeanne Zborowski; Myoung Kim

    2006-12-20

    Eighty-nine (89) percent of the electricity supplied in the 35-county Pittsburgh region (comprising parts of the states of Pennsylvania, Ohio, West Virginia, and Maryland) is generated by coal-fired power plants making this an ideal region in which to study the effects of the fine airborne particulates designated as PM{sub 2.5} emitted by the combustion of coal. This report demonstrates that during the period from 1999-2006 (1) sufficient and extensive exposure data, in particular samples of speciated PM{sub 2.5} components from 1999 to 2003, and including gaseous co-pollutants and weather have been collected, (2) sufficient and extensive mortality, morbidity, and related health outcomes data are readily available, and (3) the relationship between health effects and fine particulates can most likely be satisfactorily characterized using a combination of sophisticated statistical methodologies including latent variable modeling (LVM) and generalized linear autoregressive moving average (GLARMA) time series analysis. This report provides detailed information on the available exposure data and the available health outcomes data for the construction of a comprehensive database suitable for analysis, illustrates the application of various statistical methods to characterize the relationship between health effects and exposure, and provides a road map for conducting the proposed study. In addition, a detailed work plan for conducting the study is provided and includes a list of tasks and an estimated budget. A substantial portion of the total study cost is attributed to the cost of analyzing a large number of archived PM{sub 2.5} filters. Analysis of a representative sample of the filters supports the reliability of this invaluable but as-yet untapped resource. These filters hold the key to having sufficient data on the components of PM{sub 2.5} but have a limited shelf life. If the archived filters are not analyzed promptly the important and costly information they contain will be lost.

  4. Wildland Fire Detection from Space: Theory and Application

    E-Print Network [OSTI]

    Baum, Bryan A.

    Wildland Fire Detection from Space: Theory and Application Donald R. Cahoon, Jr.1, Brian J. Stocks2 USA 5Fire Ecology Research Group, University of Freiburg, Germany Pulished in: Biomass Burning and its instruments are currently being designed specifically for fire detection, even though to date the detection

  5. ENGINEERING FEATURES OF THE FUSION IGNITION RESEARCH EXPERIMENT (FIRE)

    E-Print Network [OSTI]

    ENGINEERING FEATURES OF THE FUSION IGNITION RESEARCH EXPERIMENT (FIRE) R.J. Thomea and P.J. Heitzenroederb for the FIRE Design Team a MIT Plasma Science and Fusion Center, 185 Albany St, Cambridge, MA, USA Box 451, Princeton, NJ, USA 08543 The FIRE tokamak is an option for the next step in the US magnetic

  6. 1-4244-1455-5/07/$25.00 c 2007 IEEE Wireless Sensor Networks for Early Detection of Forest Fires

    E-Print Network [OSTI]

    Hefeeda, Mohammed

    1-4244-1455-5/07/$25.00 c 2007 IEEE Wireless Sensor Networks for Early Detection of Forest Fires fires. We first present the key aspects in modeling forest fires. We do this by ana- lyzing the Fire detection systems. The FWI System is one of the most comprehensive forest fire danger rating systems

  7. Rate Schedules

    Broader source: Energy.gov [DOE]

    One of the major responsibilities of Southeastern is to design, formulate, and justify rate schedules. Repayment studies prepared by the agency determine revenue requirements and appropriate rate...

  8. Annual Fire Safety Report

    E-Print Network [OSTI]

    Al Faruque, Mohammad Abdullah

    1 2014 Annual Fire Safety Report University of California Campus Fire Marshals HIGHER EDUCATION to the Fire Safety in Student Housing Buildings of current or perspective students and employees be reported INTRODUCTION Fire Safety is an essential tool in protecting a campus community from injuries, deaths, business

  9. Annual Fire Safety Report

    E-Print Network [OSTI]

    2014 Annual Fire Safety Report University of California, Santa Barbara Fire Marshals) requires that certain information pertaining to the Fire Safety in Student Housing Buildings of current. #12; 2 9/19/14 HIGHER EDUCATION OPPORTUNITY ACT INTRODUCTION Fire Safety is an essential tool

  10. Fire Safety January 2011

    E-Print Network [OSTI]

    Lennard, William N.

    1 Fire Safety PROCEDURES January 2011 firesafety@uwo.ca Campus Phones ­ EMERGENCY ­ Dial 911 Fire Safety Service is the focal point for the coordinated administration of the University Fire Safety program and plans, and is the University's representative in contacts dealing with all aspects of Fire

  11. Residence Hall Fire Safety

    E-Print Network [OSTI]

    Residence Hall Fire Safety Information Department of Public Safety Residential Life & Housing #12;Part 1 ! Building Information Pursuant to New York City Fire Code and Local Law 10, this Fire Safety, as well as what to do in a fire emergency. Building Construction Residential buildings built before 1968

  12. Fire Protection Program Metrics

    Broader source: Energy.gov [DOE]

    Presenter: Perry E. D ’Antonio, P.E., Acting Sr. Manager, Fire Protection - Sandia National Laboratories

  13. Farmers' Market Audit Tool These measures are designed to rate the nutrition environments of farmers' markets and produce

    E-Print Network [OSTI]

    Bushman, Frederic

    Farmers' Market Audit Tool These measures are designed to rate the nutrition environments of farmers' markets and produce stands across a variety of geographic and income settings. There are other exclusion criteria. For our purposes, a farmers' market is a common facility or area where several farmers

  14. Fire safety of LPG in marine transportation. Final report

    SciTech Connect (OSTI)

    Martinsen, W.E.; Johnson, D.W.; Welker, J.R.

    1980-06-01

    This report contains an analytical examination of cargo spill and fire hazard potential associated with the marine handling of liquefied petroleum gas (LPG) as cargo. Principal emphasis was on cargo transfer operations for ships unloading at receiving terminals, and barges loading or unloading at a terminal. Major safety systems, including emergency shutdown systems, hazard detection systems, and fire extinguishment and control systems were included in the analysis. Spill probabilities were obtained from fault tree analyses utilizing composite LPG tank ship and barge designs. Failure rates for hardware in the analyses were generally taken from historical data on similar generic classes of hardware, there being very little historical data on the specific items involved. Potential consequences of cargo spills of various sizes are discussed and compared to actual LPG vapor cloud incidents. The usefulness of hazard mitigation systems (particularly dry chemical fire extinguishers and water spray systems) in controlling the hazards posed by LPG spills and spill fires is also discussed. The analysis estimates the probability of fatality for a terminal operator is about 10/sup -6/ to 10/sup -5/ per cargo transfer operation. The probability of fatality for the general public is substantially less.

  15. LNG fire and vapor control system technologies

    SciTech Connect (OSTI)

    Konzek, G.J.; Yasutake, K.M.; Franklin, A.L.

    1982-06-01

    This report provides a review of fire and vapor control practices used in the liquefied natural gas (LNG) industry. Specific objectives of this effort were to summarize the state-of-the-art of LNG fire and vapor control; define representative LNG facilities and their associated fire and vapor control systems; and develop an approach for a quantitative effectiveness evaluation of LNG fire and vapor control systems. In this report a brief summary of LNG physical properties is given. This is followed by a discussion of basic fire and vapor control design philosophy and detailed reviews of fire and vapor control practices. The operating characteristics and typical applications and application limitations of leak detectors, fire detectors, dikes, coatings, closed circuit television, communication systems, dry chemicals, water, high expansion foam, carbon dioxide and halogenated hydrocarbons are described. Summary descriptions of a representative LNG peakshaving facility and import terminal are included in this report together with typical fire and vapor control systems and their locations in these types of facilities. This state-of-the-art review identifies large differences in the application of fire and vapor control systems throughout the LNG industry.

  16. Funding Fire: A Losing Proposition?

    E-Print Network [OSTI]

    Vaughn, Jacqueline; Cortner, Hanna J.

    2010-01-01

    Laurel. 2008. “Loss of Fire Boards Is Harmful. ” San DiegoJoe. 2008. “Supervisors Put Fire Tax on Ballot. ” RamonaBoard. 2009. Quadrennial Fire Review 2009. Washington,

  17. Hydrocarbon characterization experiments in fully turbulent fires.

    SciTech Connect (OSTI)

    Ricks, Allen; Blanchat, Thomas K.

    2007-05-01

    As the capabilities of numerical simulations increase, decision makers are increasingly relying upon simulations rather than experiments to assess risks across a wide variety of accident scenarios including fires. There are still, however, many aspects of fires that are either not well understood or are difficult to treat from first principles due to the computational expense. For a simulation to be truly predictive and to provide decision makers with information which can be reliably used for risk assessment the remaining physical processes must be studied and suitable models developed for the effects of the physics. The model for the fuel evaporation rate in a liquid fuel pool fire is significant because in well-ventilated fires the evaporation rate largely controls the total heat release rate from the fire. A set of experiments are outlined in this report which will provide data for the development and validation of models for the fuel regression rates in liquid hydrocarbon fuel fires. The experiments will be performed on fires in the fully turbulent scale range (> 1 m diameter) and with a number of hydrocarbon fuels ranging from lightly sooting to heavily sooting. The importance of spectral absorption in the liquid fuels and the vapor dome above the pool will be investigated and the total heat flux to the pool surface will be measured. The importance of convection within the liquid fuel will be assessed by restricting large scale liquid motion in some tests. These data sets will provide a sound, experimentally proven basis for assessing how much of the liquid fuel needs to be modeled to enable a predictive simulation of a fuel fire given the couplings between evaporation of fuel from the pool and the heat release from the fire which drives the evaporation.

  18. Sliding Mode Flow Rate Observer Design Song Liu and Bin Yao

    E-Print Network [OSTI]

    Yao, Bin

    with the control valves (i.e., the cylinder internal and external leakage flows, and so on). It is assumed that: a rate information is needed in a lot of applications, such as automated modelling of valve flow mapping

  19. Design Studies for a High-Repetition-Rate FEL Facility at LBNL.

    E-Print Network [OSTI]

    CORLETT, J.

    2009-01-01

    high-resolution diagnostics of photon and electron beams, tobeams, free-electron lasers, photocathodes, high-repetition-rate electron-gun systems, laser systems, CW superconducting rf cryomodules, diagnostics,

  20. Design and testing of a microvalve capable of precisely controlling low fluidic flow rates

    E-Print Network [OSTI]

    Daniel, Cody R

    2011-01-01

    Development of the design, manufacture, and testing for a gas flow regulating microvalve is presented herein. The microvalve project served as a test bed for new micromachining techniques and for exploration of MEMS devices ...

  1. Test Plan to Assess Fire Effects on the Function of an Engineered Surface Barrier

    SciTech Connect (OSTI)

    Ward, Anderson L.; Berlin, Gregory T.; Cammann, Jerry W.; Leary, Kevin D.; Link, Steven O.

    2008-09-29

    Wildfire is a frequent perturbation in shrub steppe ecosystems, altering the flora, fauna, atmosphere, and soil of these systems. Research on the fire effects has focused mostly on natural ecosystems with essentially no attention on engineered systems like surface barriers. The scope of the project is to use a simulated wildfire to induce changes in an engineered surface barrier and document the effects on barrier performance. The main objective is to quantify the effects of burning and the resulting post-fire conditions on alterations in soil physical properties; hydrologic response, particularly the water balance; geochemical properties; and biological properties. A secondary objective is to use the lessons learned to maximize fire protection in the design of long-term monitoring systems based on electronic sensors. A simulated wildfire will be initiated, controlled and monitored at the 200-BP-1 barrier in collaboration with the Hanford Fire Department during the fall of 2008. The north half of the barrier will be divided into nine 12 x 12 m plots, each of which will be randomly assigned a fuel load of 2 kg m-2 or 4 kg m-2. Each plot will be ignited around the perimeter and flames allowed to carry to the centre. Any remaining unburned vegetation will be manually burned off using a drip torch. Progress of the fire and its effects will be monitored using point measurements of thermal, hydrologic, and biotic variables. Three measures of fire intensity will be used to characterize fire behavior: (1) flame height, (2) the maximum temperature at three vertical profile levels, and (3) total duration of elevated temperature at these levels. Pre-burn plant information, including species diversity, plant height, and canopy diameter will be measured on shrubs from the plots to be burned and from control plots at the McGee ranch. General assessments of shrub survival, recovery, and recruitment will be made after the fire. Near-surface soil samples will be collected pre- and post-burn to determine changes in the gravel content of the surface layer so as to quantify inflationary or deflationary responses to fire and to reveal the ability of the surface to resist post-fire erosive stresses. Measures of bulk density, water repellency, water retention, and hydraulic conductivity will be used to characterize changes in infiltration rates and water storage capacity following the fire. Samples will also be analyzed to quantify geochemical changes including changes in soil pH, cation exchange capacity, specific surface area, and the concentration of macro nutrients (e.g. N, P, K) and other elements such as Na, Mg, Ca, that are critical to the post-fire recovery revegetation. Soil CO2 emissions will be measured monthly for one year following the burn to document post-fire stimulation of carbon turnover and soil biogenic emissions. Surface and subsurface temperature measurements at and near monitoring installations will be used to document fire effects on electronic equipment. The results of this study will be used to bridge the gaps in knowledge on the effects of fire on engineered ecosystems (e.g. surface barriers), particularly the hydrologic and biotic characteristics that govern the water and energy balance. These results will also support the development of practical fire management techniques for barriers that are compatible with wildfire suppression strategies. Furthermore, lessons learned will be use to develop installation strategies needed to protect electronic monitoring equipment from the intense heat of fire and the potential damaging effects of smoke and fire extinguishing agents. Such information is needed to better understand long-term barrier performance under extreme conditions, especially if site maintenance and operational funding is lost for activities such as barrier revegetation.

  2. Improvement of the process of fuel firing on BKZ-210-140F boilers

    SciTech Connect (OSTI)

    V.V. Osintsev; M.P. Sukharev; E.V. Toropov; K.V. Osintsev

    2007-01-15

    The existing flame processes of dual firing of gas and solid fuel are updated with reconstruction of the burners at the Chelyabinsk TETs-2. This is connected with marked worsening of the quality of local coal supplied to the cogeneration plant. Comparative tests of boilers with burners subjected to different degrees of updating have shown that replacement of the now used swirled method of introduction of reagents into the furnace by a uniflow one lowers the heat flows to the metal structures and to the settling of the burner throats making them more reliable. The emission of nitrogen oxides is minimized in the mode of gas firing and the activity of slagging of the furnace and of the platens is reduced in the mode of coal firing, which makes it possible to raise the steam rate of the boiler. Ways for further improvement of burner design with respect to nitrogen oxide emissions in the polydisperse flame are outlined.

  3. The Westmount Arena Fire 

    E-Print Network [OSTI]

    Gales, John

    A short article on the origins of professional ice hockey in Canada. The article describes an early fire of an arena in Westmount Montreal, QC. This fire's impact on professional ice hockey is discussed as well as initial details about...

  4. Fire Size in Tunnels 

    E-Print Network [OSTI]

    Carvel, Ricky O

    In recent years, a number of high profile accidental fires have occurred in several road and rail tunnels throughout the world. Many of these fires grew rapidly to catastrophic size and claimed many lives. The processes ...

  5. Rate impacts and key design elements of gas and electric utility decoupling: a comprehensive review

    SciTech Connect (OSTI)

    Lesh, Pamela G.

    2009-10-15

    Opponents of decoupling worry that customers will experience frequent and significant rate increases as a result of its adoption, but a review of 28 natural gas and 17 electric utilities suggests that decoupling adjustments are both refunds to customers as well as charges and tend to be small. (author)

  6. Fire in Buildings 

    E-Print Network [OSTI]

    Shorter, G.

    During the lifetime of any building in Canada it is probable that one or more "unwanted" fires will occur. "Fire Loss in Canada, 1959," the report of the Dominion Fire Commissioner, states that for the period 1950-1959 the average number of reported...

  7. Unbonded Post Tensioned Concrete in Fire: A Review of Data from Furnace Tests and Real Fires 

    E-Print Network [OSTI]

    Gales, John; Bisby, Luke; Gillie, Martin

    The fire-safe design of concrete structures which incorporate post-tensioned prestressing tendons has recently been the subject of debate within the structural engineering community, particularly when unbonded post-tensioned ...

  8. LETTER Communicated by Nancy Kopell Fast Global Oscillations in Networks of Integrate-and-Fire

    E-Print Network [OSTI]

    Hakim, Vincent

    LETTER Communicated by Nancy Kopell Fast Global Oscillations in Networks of Integrate-and-Fire Neurons with Low Firing Rates Nicolas Brunel Vincent Hakim LPS, Ecole Normale Sup´erieure, 75231 Paris integrate-and-fire neurons in a regime where individual neu- rons emit spikes irregularly and at a low rate

  9. Fire Protection Program Manual

    SciTech Connect (OSTI)

    Sharry, J A

    2012-05-18

    This manual documents the Lawrence Livermore National Laboratory (LLNL) Fire Protection Program. Department of Energy (DOE) Orders 420.1B, Facility Safety, requires LLNL to have a comprehensive and effective fire protection program that protects LLNL personnel and property, the public and the environment. The manual provides LLNL and its facilities with general information and guidance for meeting DOE 420.1B requirements. The recommended readers for this manual are: fire protection officers, fire protection engineers, fire fighters, facility managers, directorage assurance managers, facility coordinators, and ES and H team members.

  10. A comparison of geospatially modeled fire behavior and fire management utility of three data sources in the southeastern United States.

    SciTech Connect (OSTI)

    Hollingsworth, LaWen T.; Kurth, Laurie,; Parresol, Bernard, R.; Ottmar, Roger, D.; Prichard, Susan J.

    2012-01-01

    Landscape-scale fire behavior analyses are important to inform decisions on resource management projects that meet land management objectives and protect values from adverse consequences of fire. Deterministic and probabilistic geospatial fire behavior analyses are conducted with various modeling systems including FARSITE, FlamMap, FSPro, and Large Fire Simulation System. The fundamental fire intensity algorithms in these systems require surface fire behavior fuel models and canopy cover to model surface fire behavior. Canopy base height, stand height, and canopy bulk density are required in addition to surface fire behavior fuel models and canopy cover to model crown fire activity. Several surface fuel and canopy classification efforts have used various remote sensing and ecological relationships as core methods to develop the spatial layers. All of these methods depend upon consistent and temporally constant interpretations of crown attributes and their ecological conditions to estimate surface fuel conditions. This study evaluates modeled fire behavior for an 80,000 ha tract of land in the Atlantic Coastal Plain of the southeastern US using three different data sources. The Fuel Characteristic Classification System (FCCS) was used to build fuelbeds from intensive field sampling of 629 plots. Custom fire behavior fuel models were derived from these fuelbeds. LANDFIRE developed surface fire behavior fuel models and canopy attributes for the US using satellite imagery informed by field data. The Southern Wildfire Risk Assessment (SWRA) developed surface fire behavior fuel models and canopy cover for the southeastern US using satellite imagery. Differences in modeled fire behavior, data development, and data utility are summarized to assist in determining which data source may be most applicable for various land management activities and required analyses. Characterizing fire behavior under different fuel relationships provides insights for natural ecological processes, management strategies for fire mitigation, and positive and negative features of different modeling systems. A comparison of flame length, rate of spread, crown fire activity, and burn probabilities modeled with FlamMap shows some similar patterns across the landscape from all three data sources, but there are potentially important differences. All data sources showed an expected range of fire behavior. Average flame lengths ranged between 1 and 1.4 m. Rate of spread varied the greatest with a range of 2.4-5.7 m min{sup -1}. Passive crown fire was predicted for 5% of the study area using FCCS and LANDFIRE while passive crown fire was not predicted using SWRA data. No active crown fire was predicted regardless of the data source. Burn probability patterns across the landscape were similar but probability was highest using SWRA and lowest using FCCS.

  11. FEMP Designated Product Assessment for Commercial Gas Water Heaters

    E-Print Network [OSTI]

    Lutz, Jim

    2012-01-01

    Water Heaters Appliance Gas storage water heaters Definitionto use for rating gas-fired storage and instantaneous waterefficiency for all gas-fired storage and instantaneous water

  12. Ignition and spread of electrical wire fires

    E-Print Network [OSTI]

    Huang, Xinyan

    2012-01-01

    1.1 Electrical Wire Fires 1.2 Literature Review . . 1.3d) Electrical fires. . . . . . . . . . . . . . . . . . . .of the fire performance of electrical cables,” Fire Safety

  13. The Behaviour of Steel-Framed Composite Structures in Fire Conditions 

    E-Print Network [OSTI]

    Gillie, Martin

    Over the last decade it has become increasingly clear that the traditional methods of fire safety design can be unnecessarily conservative and therefore expensive. In 1995 a series of fire tests were carried out at Cardington, ...

  14. Design, microstructure, and high-temperature behavior of silicon nitride sintered with rate-earth oxides

    SciTech Connect (OSTI)

    Ciniculk, M.K. (California Univ., Berkeley, CA (United States). Dept. of Materials Science and Mineral Engineering)

    1991-08-01

    The processing-microstructure-property relations of silicon nitride ceramics sintered with rare-earth oxide additives have been investigated with the aim of improving their high-temperature behavior. The additions of the oxides of Y, Sm, Gd, Dy, Er, or Yb were compositionally controlled to tailor the intergranular phase. The resulting microstructure consisted of {beta}-Si{sub 3}N{sub 4} grains and a crystalline secondary phase of RE{sub 2}Si{sub 2}O{sub 7}, with a thin residual amorphous phase present at grain boundaries. The lanthanide oxides were found to be as effective as Y{sub 2}O{sub 3} in densifying Si{sub 3}N{sub 4}, resulting in identical microstructures. The crystallization behavior of all six disilicates was similar, characterized by a limited nucleation and rapid growth mechanism resulting in large single crystals. Complete crystallization of the intergranular phase was obtained with the exception of a residual amorphous, observed at interfaces and believed to be rich in impurities, the cause of incomplete devitrification. The low resistance to oxidation of these materials was attributed to the minimization of amorphous phases via devitrification to disilicates, compatible with SiO{sub 2}, the oxidation product of Si{sub 3}N{sub 4}. The strength retention of these materials at 1300{degrees}C was found to be between 80% and 91% of room-temperature strength, due to crystallization of the secondary phase and a residual but refractory amorphous grain-boundary phase. The creep behavior was found to be strongly dependent on residual amorphous phase viscosity as well as on the oxidation behavior, as evidenced by the nonsteady-state creep rates of all materials. 122 refs., 51 figs., 12 tabs.

  15. Municipal waste combustion assessment: Fossil fuel co-firing. Final report, October 1988-July 1989

    SciTech Connect (OSTI)

    Landrum, V.J.; Barton, R.G.

    1989-07-01

    The report identifies refuse derived fuel (RDF) processing operations and various RDF types; describes such fossil fuel co-firing techniques as coal fired spreader stokers, pulverized coal wall fired boilers, pulverized coal tangentially fired boilers, and cyclone fired boilers; and describes the population of coal fired boilers that currently co-fire RDF, have previously co-fired RDF but have ceased to do so, and have been used in RDF co-firing demonstrations. (Fossil fuel co-firing, defined as the combustion of RDF with another fuel (usually coal) in a device designed primarily to burn the other fuel, is generally confined to commercial and utility boilers.) Model plants are developed and good combustion practices are recommended.

  16. GREENHOUSE GAS EMISSIONS CONTROL BY OXYGEN FIRING IN CIRCULATING FLUIDIZED BED BOILERS: PHASE II--PILOT SCALE TESTING AND UPDATED PERFORMANCE AND ECONOMICS FOR OXYGEN FIRED CFB WITH CO2 CAPTURE

    SciTech Connect (OSTI)

    Nsakala ya Nsakala; Gregory N. Liljedahl; David G. Turek

    2004-10-27

    Because fossil fuel fired power plants are among the largest and most concentrated producers of CO{sub 2} emissions, recovery and sequestration of CO{sub 2} from the flue gas of such plants has been identified as one of the primary means for reducing anthropogenic CO{sub 2} emissions. In this Phase II study, ALSTOM Power Inc. (ALSTOM) has investigated one promising near-term coal fired power plant configuration designed to capture CO{sub 2} from effluent gas streams for sequestration. Burning fossil fuels in mixtures of oxygen and recirculated flue gas (made principally of CO{sub 2}) essentially eliminates the presence of atmospheric nitrogen in the flue gas. The resulting flue gas is comprised primarily of CO{sub 2}, along with some moisture, nitrogen, oxygen, and trace gases like SO{sub 2} and NO{sub x}. Oxygen firing in utility scale Pulverized Coal (PC) fired boilers has been shown to be a more economical method for CO{sub 2} capture than amine scrubbing (Bozzuto, et al., 2001). Additionally, oxygen firing in Circulating Fluid Bed Boilers (CFB's) can be more economical than in PC or Stoker firing, because recirculated gas flow can be reduced significantly. Oxygen-fired PC and Stoker units require large quantities of recirculated flue gas to maintain acceptable furnace temperatures. Oxygen-fired CFB units, on the other hand, can accomplish this by additional cooling of recirculated solids. The reduced recirculated gas flow with CFB plants results in significant Boiler Island cost savings resulting from reduced component The overall objective of the Phase II workscope, which is the subject of this report, is to generate a refined technical and economic evaluation of the Oxygen fired CFB case (Case-2 from Phase I) utilizing the information learned from pilot-scale testing of this concept. The objective of the pilot-scale testing was to generate detailed technical data needed to establish advanced CFB design requirements and performance when firing coals and delayed petroleum coke in O{sub 2}/CO{sub 2} mixtures. Firing rates in the pilot test facility ranged from 2.2 to 7.9 MM-Btu/hr. Pilot-scale testing was performed at ALSTOM's Multi-use Test Facility (MTF), located in Windsor, Connecticut.

  17. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    SciTech Connect (OSTI)

    Energy and Resources Group, University of California, Berkeley; Darghouth, Naim R.; Barbose, Galen; Wiser, Ryan

    2011-06-01

    Net metering has become a widespread mechanism in the U.S. for supporting customer adoption of distributed photovoltaics (PV), but has faced challenges as PV installations grow to a larger share of generation in a number of states. This paper examines the value of the bill savings that customers receive under net metering, and the associated role of retail rate design, based on a sample of approximately two hundred residential customers of California's two largest electric utilities. We find that the bill savings per kWh of PV electricity generated varies by more than a factor of four across the customers in the sample, which is largely attributable to the inclining block structure of the utilities' residential retail rates. We also compare the bill savings under net metering to that received under three potential alternative compensation mechanisms, based on California's Market Price Referent (MPR). We find that net metering provides significantly greater bill savings than a full MPR-based feed-in tariff, but only modestly greater savings than alternative mechanisms under which hourly or monthly net excess generation is compensated at the MPR rate.

  18. Direct-fired biomass

    SciTech Connect (OSTI)

    None, None

    2009-01-18

    The direct-fired biomass section of the Renewable Energy Technology Characterizations describes the technical and economic status of this emerging renewable energy option for electricity supply.

  19. Co-firing biomass

    SciTech Connect (OSTI)

    Hunt, T.; Tennant, D. [Hunt, Guillot & Associates LLC (United States)

    2009-11-15

    Concern about global warming has altered the landscape for fossil-fuel combustion. The advantages and challenges of co-firing biomass and coal are discussed. 2 photos.

  20. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01

    Electricity Rates..generation at retail electricity rates (Rose et al. 2009).of the underlying retail electricity rate, as well as on the

  1. Structural Design Criteria Irving J. Zatz, PPPL

    E-Print Network [OSTI]

    1 FIRE Structural Design Criteria Irving J. Zatz, PPPL Engineering Peer Review June 5-7, 2001 #12;2 Purpose of FIRE Design Criteria · Criteria to be utilized when conventional industrial design codes and standards do not apply ­ Operating conditions ­ Materials #12;3 The FIRE Design Criteria has evolved from

  2. Model Baseline Fire Department/Fire Protection Engineering Assessment

    Broader source: Energy.gov [DOE]

    The purpose of the document is to comprehensively delineate and rationalize the roles and responsibilities of the Fire Department and Fire Protection (Engineering).

  3. Condensing economizers for small coal-fired boilers and furnaces

    SciTech Connect (OSTI)

    Butcher, T.A.; Litzke, W.

    1994-01-01

    Condensing economizers increase the thermal efficiency of boilers by recovering sensible and latent heat from exhaust gas. These economizers are currently being used commercially for this purpose in a wide range of applications. Performance is dependent upon application-specific factors affecting the utility of recovered heat. With the addition of a condensing economizer boiler efficiency improvements up to 10% are possible. Condensing economizers can also capture flue gas particulates. In this work, the potential use of condensing economizers for both efficiency improvement and control of particulate emissions from small, coal water slurry-fired boilers was evaluated. Analysis was done to predict heat transfer and particulate capture by mechanisms including: inertial impaction, interception, diffusion, thermophoretic forces, and condensation growth. Shell-and-tube geometries were considered with flue gas on the outside of Teflon-covered tubes. Experimental studies were done with both air- and water-cooled economizers refit to a small boiler. Two experimental arrangements were used including oil-firing with injection of flyash upstream of the economizer and direct coal water slurry firing. Firing rates ranged from 27 to 82 kW (92,000 to 280,000 Btu/hr). Inertial impaction was found to be the most important particulate capture mechanism and removal efficiencies to 95% were achieved. With the addition of water sprays directly on the first row of tubes, removal efficiencies increased to 98%. Use of these sprays adversely affects heat recovery. Primary benefits of the sprays are seen to be the addition of small impaction sites and future design improvements are suggested in which such small impactors are permanently added to the highest velocity regions of the economizer. Predicted effects of these added impactors on particulate removal and pressure drop are presented.

  4. Knowledge and plan execution management in planning fire fighting operations

    E-Print Network [OSTI]

    Fernández Olivares, Juan

    Knowledge and plan execution management in planning fire fighting operations Marc de la Asunci to assist human experts in the design of forest fire fighting plans. Issues about how to engineer planning knowledge for such a system, how to monitor the execution of fighting plans and how to patch unfeasible

  5. Spontaneous Neural Firing in Biological & Artificial Neural Systems Christian R. Huyck and Richard Bowles

    E-Print Network [OSTI]

    Huyck, Chris

    Spontaneous Neural Firing in Biological & Artificial Neural Systems Christian R. Huyck and Richard of spontaneous neural activation may actually improve the system. Spontaneous neural firing can attenuate neural for a long period (relative to their normal firing rate), typically several milliseconds. When a neuron has

  6. Fire science at LLNL: A review

    SciTech Connect (OSTI)

    Hasegawa, H.K. (ed.)

    1990-03-01

    This fire sciences report from LLNL includes topics on: fire spread in trailer complexes, properties of welding blankets, validation of sprinkler systems, fire and smoke detectors, fire modeling, and other fire engineering and safety issues. (JEF)

  7. Locomotive design and construction /

    E-Print Network [OSTI]

    Maris, James Clyde.

    1919-01-01

    . Proportions of Locomotive 20 Comparison of various factors. Boilers 23 Types, boiler performance, details, fire box design and performance, grate design, ash pan design, petti­ coat pipe and front end arrangement, stack design, exhaust nozzle sizes..., fittings and appliances, brick arches. Boiler Making 46 Laying out templates, forming the plates, flange block design, swageblock design, fitting up, testing, firing up. Superheated Steam for Locomotives 58 Modern practice, types of superheaters...

  8. Electronic firing systems and methods for firing a device

    DOE Patents [OSTI]

    Frickey, Steven J. (Boise, ID); Svoboda, John M. (Idaho Falls, ID)

    2012-04-24

    An electronic firing system comprising a control system, a charging system, an electrical energy storage device, a shock tube firing circuit, a shock tube connector, a blasting cap firing circuit, and a blasting cap connector. The control system controls the charging system, which charges the electrical energy storage device. The control system also controls the shock tube firing circuit and the blasting cap firing circuit. When desired, the control system signals the shock tube firing circuit or blasting cap firing circuit to electrically connect the electrical energy storage device to the shock tube connector or the blasting cap connector respectively.

  9. EMERGENCY PROCEDURES * Activate the nearest fire alarm pull station and call

    E-Print Network [OSTI]

    Arnold, Elizabeth A.

    EMERGENCY PROCEDURES FIRE * Activate the nearest fire alarm pull station and call 568 a fire alarm is activated, even if there are no obvious signs of an emergency! * DO NOT use the elevator by emergency personnel and respond to location designated by your building coordinator outside the structure

  10. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    SciTech Connect (OSTI)

    Darghouth, Naim; Barbose, Galen; Wiser, Ryan

    2010-03-30

    Net metering has become a widespread policy in the U.S. for supporting distributed photovoltaics (PV) adoption. Though specific design details vary, net metering allows customers with PV to reduce their electric bills by offsetting their consumption with PV generation, independent of the timing of the generation relative to consumption - in effect, compensating the PV generation at retail electricity rates (Rose et al. 2009). While net metering has played an important role in jump-starting the residential PV market in the U.S., challenges to net metering policies have emerged in a number of states and contexts, and alternative compensation methods are under consideration. Moreover, one inherent feature of net metering is that the value of the utility bill savings it provides to customers with PV depends heavily on the structure of the underlying retail electricity rate, as well as on the characteristics of the customer and PV system. Consequently, the value of net metering - and the impact of moving to alternative compensation mechanisms - can vary substantially from one customer to the next. For these reasons, it is important for policymakers and others that seek to support the development of distributed PV to understand both how the bill savings varies under net metering, and how the bill savings under net metering compares to other possible compensation mechanisms. To advance this understanding, we analyze the bill savings from PV for residential customers of California's two largest electric utilities, Pacific Gas and Electric (PG&E) and Southern California Edison (SCE). The analysis is based on hourly load data from a sample of 215 residential customers located in the service territories of the two utilities, matched with simulated hourly PV production for the same time period based on data from the nearest of 73 weather stations in the state.

  11. Superclean coal-water slurry combustion testing in an oil-fired boiler

    SciTech Connect (OSTI)

    Miller, B.G.; Schobert, H.H.

    1990-09-28

    The Pennsylvania State University is conducting a superclean coal-water slurry (SCCWS) program with the objective of demonstrating the capability of effectively firing SCCWS in industrial boilers designed for oil. Penn State has entered into a cooperative agreement with DOE to determine if SCCWS (a fuel containing coal with less than 3.0% ash and 0.9% sulfur) can effectively be burned in oil-designed industrial boilers without adverse impact on boiler rating, maintainability, reliability and availability. The project will provide information on the design of new systems specifically configured to fire these clean coal-based fuels. The project consists of three phases: (1) design, permitting, and test planning, (2) construction and start up, and (3) demonstration and evaluation. The boiler testing will determine if the SCCWS combustion characteristics, heat release rate, fouling and slagging behavior, corrosion and erosion limits, and fuel transport, storage, and handling characteristics can be accommodated in an oil-designed boiler system. In addition, the proof-of-concept demonstration will generate data to determine how the properties of SCCWS and its parent coal affect boiler performance. Economic factors associated with retrofitting and operating boilers will be identified to assess the viability of future oil-to-coal retrofits. Progress is reported. 7 refs., 7 figs., 1 tab.

  12. Flooding and Fire Ants 

    E-Print Network [OSTI]

    Nester, Paul

    2008-08-05

    Fire ants can be a serious problem during and after a flood. This publication explains how to protect yourself when you must return to flooded structures or deal with storm debris....

  13. Management strategy for fire 

    E-Print Network [OSTI]

    Naylor, C.; Capper, W.; Wilson, C. P.; Harcourt, E.; Voss, B. L. D.; Inger, J.; Murray, K. C.; Carnegie, L.

    1972-01-01

    This publication describes how fire protection thinking should be applied to a total business, rather than just to the safeguarding of building and contents. The subject is approached from the standpoint of being self-insured. ...

  14. FIELD TEST PROGRAM TO DEVELOP COMPREHENSIVE DESIGN, OPERATING AND COST DATA FOR MERCURY CONTROL SYSTEMS ON NON-SCRUBBED COAL-FIRED BOILERS

    SciTech Connect (OSTI)

    C. Jean Bustard

    2001-07-31

    With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Mercury is known to have toxic effects on the nervous system of humans and wildlife. Although it exists only in trace amounts in coal, mercury is released when coal burns and can accumulate on land and in water. In water, bacteria transform the metal into methylmercury, the most hazardous form of the metal. Methylmercury can collect in fish and marine mammals in concentrations hundreds of thousands times higher than the levels in surrounding waters. One of the goals of DOE is to develop technologies by 2005 that will be capable of cutting mercury emissions 50 to 70 percent at well under one-half of today's costs. ADA Environmental Solutions (ADA-ES) is managing a project to test mercury control technologies at full scale at four different power plants from 2000 to 2003. The ADA-ES project is focused on those power plants that are not equipped with wet flue gas desulfurization systems. ADA-ES will develop a portable system that will be moved to four different utility power plants for field testing. Each of the plants is equipped with either electrostatic precipitators or fabric filters to remove solid particles from the plant's flue gas. ADA-ES's technology will inject a dry sorbent, such as fly ash or activated carbon, that removes the mercury and makes it more susceptible to capture by the particulate control devices. A fine water mist may be sprayed into the flue gas to cool its temperature to the range where the dry sorbent is most effective. PG and E National Energy Group is providing two test sites that fire bituminous coals and are both equipped with electrostatic precipitators and carbon/ash separation systems. Wisconsin Electric Power Company is providing a third test site that burns Powder River Basin (PRB) coal and has an electrostatic precipitator for particulate control. Alabama Power Company will host a fourth test at its Plant Gaston, which is equipped with a hot-side electrostatic precipitator and a downstream fabric filter.

  15. FIELD TEST PROGRAM TO DEVELOP COMPREHENSIVE DESIGN, OPERATING AND COST DATA FOR MERCURY CONTROL SYSTEMS ON NON-SCRUBBED COAL-FIRED BOILERS

    SciTech Connect (OSTI)

    C. Jean Bustard

    2001-10-01

    With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Mercury is known to have toxic effects on the nervous system of humans and wildlife. Although it exists only in trace amounts in coal, mercury is released when coal burns and can accumulate on land and in water. In water, bacteria transform the metal into methylmercury, the most hazardous form of the metal. Methylmercury can collect in fish and marine mammals in concentrations hundreds of thousands times higher than the levels in surrounding waters. One of the goals of DOE is to develop technologies by 2005 that will be capable of cutting mercury emissions 50 to 70 percent at well under one-half of today's costs. ADA Environmental Solutions (ADA-ES) is managing a project to test mercury control technologies at full scale at four different power plants from 2000--2003. The ADA-ES project is focused on those power plants that are not equipped with wet flue gas desulfurization systems. ADA-ES will develop a portable system that will be moved to four different utility power plants for field testing. Each of the plants is equipped with either electrostatic precipitators or fabric filters to remove solid particles from the plant's flue gas. ADA-ES's technology will inject a dry sorbent, such as fly ash or activated carbon, that removes the mercury and makes it more susceptible to capture by the particulate control devices. A fine water mist may be sprayed into the flue gas to cool its temperature to the range where the dry sorbent is most effective. PG&E National Energy Group is providing two test sites that fire bituminous coals and are both equipped with electrostatic precipitators and carbon/ash separation systems. Wisconsin Electric Power Company is providing a third test site that burns Powder River Basin (PRB) coal and has an electrostatic precipitator for particulate control. Alabama Power Company will host a fourth test at its Plant Gaston, which is equipped with a hot-side electrostatic precipitator and a downstream fabric filter.

  16. Fire protection countermeasures for containment ventilation systems

    SciTech Connect (OSTI)

    Alvares, N.J.; Beason, D.G.; Bergman, W.; Ford, H.W.; Lipska, A.E.

    1980-01-01

    The goal of this project is to find countermeasures to protect HEPA filters in exit ventilation ducts from the heat and smoke generated by fire. Several methods for partially mitigating the smoke exposure to the HEPA filters were identified through testing and analysis. These independently involve controlling the fuel, controlling the fire, and intercepting the smoke aerosol prior to its sorption on the HEPA filter. Exit duct treatment of aerosols is not unusual in industrial applications and involves the use of scrubbers, prefilters, and inertial impaction, depending on the size, distribution, and concentration of the subject aerosol. However, when these unmodified techniques were applied to smoke aerosols from fires on materials, common to experimental laboratories of LLNL, it was found they offered minimal protection to the HEPA filters. Ultimately, a continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. This technique is capable of protecting HEPA filters over the total duration of the test fires. The reason for success involved the modificaton of the prefiltration media. Commercially available filter media has a particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, we laminated rolling filter media with the desired properties. It is not true that the use of rolling prefilters solely to protect HEPA filters from fire-generated smoke aerosols is cost effective in every type of containment system, especially if standard fire-protection systems are available in the space. But in areas of high fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified.

  17. FIELD TEST PROGRAM TO DEVELOP COMPREHENSIVE DESIGN, OPERATING AND COST DATA FOR MERCURY CONTROL SYSTEMS ON NON-SCRUBBED COAL-FIRED BOILERS

    SciTech Connect (OSTI)

    Richard Schlager; Tom Millar

    2003-01-27

    With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Mercury is known to have toxic effects on the nervous system of humans and wildlife. Although it exists only in trace amounts in coal, mercury is released when coal burns and can accumulate on land and in water. In water, bacteria transform the metal into methylmercury, the most hazardous form of the metal. Methylmercury can collect in fish and marine mammals in concentrations hundreds of thousands times higher than the levels in surrounding waters. One of the goals of DOE is to develop technologies by 2005 that will be capable of cutting mercury emissions 50 to 70 percent at well under one-half of today's costs. ADA Environmental Solutions (ADA-ES) is managing a project to test mercury control technologies at full scale at four different power plants from 2000-2003. The ADA-ES project is focused on those power plants that are not equipped with wet flue gas desulfurization systems. ADA-ES has developed a portable system that will be tested at four different utility power plants. Each of the plants is equipped with either electrostatic precipitators or fabric filters to remove solid particles from the plant's flue gas. ADA-ES's technology will inject a dry sorbent, such as activated carbon, which removes the mercury and makes it more susceptible to capture by the particulate control devices. A fine water mist may be sprayed into the flue gas to cool its temperature to the range where the dry sorbent is most effective. PG&E National Energy Group is providing two test sites that fire bituminous coals and both are equipped with electrostatic precipitators and carbon/ash separation systems. Wisconsin Electric Power Company is providing a third test site that burns Powder River Basin (PRB) coal and has an electrostatic precipitator for particulate control. Alabama Power Company will host a fourth test at its Plant Gaston, which is equipped with a hot-side electrostatic precipitator and a downstream fabric filter. During the ninth reporting quarter, progress was made on the project in the following areas: PG&E NEG Salem Harbor Station -- Long term testing and equipment decommissioning has been completed, A web cast/conference call was held to review data, and Preliminary preparation and review of data and test results for the final report. Technology Transfer -- A number of technical presentations and briefings were made during the quarter. Notable among them was a Program Status Report presented to NETL. Also, one paper was presented at Power-Gen and one at the Annual Coal Marketing Strategies Conference.

  18. FIELD TEST PROGRAM TO DEVELOP COMPREHENSIVE DESIGN, OPERATING AND COST DATA FOR MERCURY CONTROL SYSTEMS ON NON-SCRUBBED COAL-FIRED BOILERS

    SciTech Connect (OSTI)

    Richard Schlager; Tom Millar

    2002-10-18

    With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Mercury is known to have toxic effects on the nervous system of humans and wildlife. Although it exists only in trace amounts in coal, mercury is released when coal burns and can accumulate on land and in water. In water, bacteria transform the metal into methylmercury, the most hazardous form of the metal. Methylmercury can collect in fish and marine mammals in concentrations hundreds of thousands times higher than the levels in surrounding waters. One of the goals of DOE is to develop technologies by 2005 that will be capable of cutting mercury emissions 50 to 70 percent at well under one-half of today's costs. ADA Environmental Solutions (ADA-ES) is managing a project to test mercury control technologies at full scale at four different power plants from 2000-2003. The ADA-ES project is focused on those power plants that are not equipped with wet flue gas desulfurization systems. ADA-ES has developed a portable system that will be tested at four different utility power plants. Each of the plants is equipped with either electrostatic precipitators or fabric filters to remove solid particles from the plant's flue gas. ADA-ES's technology will inject a dry sorbent, such as activated carbon, which removes the mercury and makes it more susceptible to capture by the particulate control devices. A fine water mist may be sprayed into the flue gas to cool its temperature to the range where the dry sorbent is most effective. PG&E National Energy Group is providing two test sites that fire bituminous coals and both are equipped with electrostatic precipitators and carbon/ash separation systems. Wisconsin Electric Power Company is providing a third test site that burns Powder River Basin (PRB) coal and has an electrostatic precipitator for particulate control. Alabama Power Company will host a fourth test at its Plant Gaston, which is equipped with a hot-side electrostatic precipitator and a downstream fabric filter. During the eighth reporting quarter, progress was made on the project in the following areas: (1) PG&E NEG Salem Harbor Station--Sorbent injection equipment was installed at the site during the quarter; Test plans were prepared for the field-testing phase of the project; and Baseline testing was completed during the quarter. (2) Technology Transfer--A number of technical presentations and briefings were made during the quarter. Notable among them was a paper published in the JAWMA. Also, two papers were presented at the Air Quality III Conference and one at the Pittsburgh Coal Conference.

  19. FIELD TEST PROGRAM TO DEVELOP COMPREHENSIVE DESIGN, OPERATING AND COST DATA FOR MERCURY CONTROL SYSTEMS ON NON-SCRUBBED COAL-FIRED BOILERS

    SciTech Connect (OSTI)

    Richard Schlager

    2002-08-01

    With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Mercury is known to have toxic effects on the nervous system of humans and wildlife. Although it exists only in trace amounts in coal, mercury is released when coal burns and can accumulate on land and in water. In water, bacteria transform the metal into methylmercury, the most hazardous form of the metal. Methylmercury can collect in fish and marine mammals in concentrations hundreds of thousands times higher than the levels in surrounding waters. One of the goals of DOE is to develop technologies by 2005 that will be capable of cutting mercury emissions 50 to 70 percent at well under one-half of today's costs. ADA Environmental Solutions (ADA-ES) is managing a project to test mercury control technologies at full scale at four different power plants from 2000-2003. The ADA-ES project is focused on those power plants that are not equipped with wet flue gas desulfurization systems. ADA-ES will develop a portable system that will be moved to four different utility power plants for field testing. Each of the plants is equipped with either electrostatic precipitators or fabric filters to remove solid particles from the plant's flue gas. ADA-ES's technology will inject a dry sorbent, such as fly ash or activated carbon, that removes the mercury and makes it more susceptible to capture by the particulate control devices. A fine water mist may be sprayed into the flue gas to cool its temperature to the range where the dry sorbent is most effective. PG&E National Energy Group is providing two test sites that fire bituminous coals and both are equipped with electrostatic precipitators and carbon/ash separation systems. Wisconsin Electric Power Company is providing a third test site that burns Powder River Basin (PRB) coal and has an electrostatic precipitator for particulate control. Alabama Power Company will host a fourth test at its Plant Gaston, which is equipped with a hot-side electrostatic precipitator and a downstream fabric filter. During the seventh reporting quarter, progress was made on the project in the following areas: (1) PG&E NEG Brayton Point Station--Sorbent injection equipment was installed at the site during the quarter; Test plans were prepared for the field testing phase of the project; Baseline testing was completed during the quarter and parametric testing was begun; and A paper summarizing the full-scale tests was written and submitted to A&WMA for presentation at the annual meeting in June 2002. (2) Technology Transfer--A number of technical presentations and briefings were made during the quarter. Notable among them are papers published in the A&WMA EM journal and Pollution Engineering. Also, information was provided to the EPA MACT Working Group and a paper was presented at the annual A&WMA meeting.

  20. Prescribed Fire is Cool on Florida Highway

    E-Print Network [OSTI]

    Caster, Jeff; McBurney, Willson; Farley, Patricia; Rodriguez, Rose; Green, Lane; McGorty, Kevin

    2007-01-01

    plans for a prescribed fire on US319/SR61, Kate Irelandwww.longleafalliance.org). Prescribed fire is a necessaryresource. Using prescribed fire along this highway is safe

  1. Fire Protection Database | Department of Energy

    Office of Environmental Management (EM)

    Fire Protection Database Fire Protection Database DOE O 231.1, Environment, Safety, And Health Reporting, requires the submission of an Annual Fire Protection Summary. The previous...

  2. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01

    which TOU Rate is Least Cost PV-to-Load Ratio PGE (N=118)which TOU Rate is Least Cost PV-to-Load Ratio South facingfor which TOU rate is Least Cost PV-to-Load Ratio PV-to-Load

  3. CWS-fired residential warm-air heating system

    SciTech Connect (OSTI)

    Balsavich, J.C.; Becker, F.E.; Smolensky, L.A.

    1990-03-01

    The objective of the CWS-Fired Residential Warm-Air Heating System program was the development of an economically viable coal water slurry (CWS) fueled furnace that is competitive with current oil and natural gas systems. During the first phase of the program, a novel state-of-the-art Inertial Reactor with Internal Separation (IRIS) combustor was designed and tested. The second phase of the program focused on evaluating the interaction between the individual components and system design optimization. Testing was conducted on the prototype furnace. This work concentrated on optimizing the combustor configuration to yield high combustion efficiencies and prevent the possible agglomeration of coal within the combustor. Also, a new twin-fluid CWS atomizer was designed and tested. This atomizer employed a supersonic airstream to shear the CWS external to the nozzle and thereby eliminated erosion problems. Also, a new furnace system was designed, constructed, and extensively tested. This furnace, called the third-generation system, served as a basis for a manufacturing prototype and included all the necessary controls needed for automatic operation. In life testing of the third-generation furnace system, the unit operated for 200 hours and burned 1,758 pounds of CWS. This translated into an average input rate throughout the test period of 87,200 Btu/hr. During this period, combustion efficiencies ranged from 98.2 to 99.1 percent, with a noted increase in efficiency with time. This furnace was also tested in a cyclic manner for an additional period of 54 hours to evaluate the effect of thermal transients. During cyclic testing, the furnace went through repeated transient cycles, which included startup on oil, transition to CWS, and cool-down. As part of an economic evaluation the high volume cost of a CWS-fired warm air furnace was determined. 90 figs., 7 tabs.

  4. A Forest Fire Simulation Tool for Economic Planning in Fire Suppression Management

    E-Print Network [OSTI]

    Standiford, Richard B.

    A Forest Fire Simulation Tool for Economic Planning in Fire Suppression Management Models fire spread behavior of forest fires provides important information for decision-making. Specific resource positioning to control and extinguish forest fire, decisions can be validated before

  5. Cyber Friendly Fire

    SciTech Connect (OSTI)

    Greitzer, Frank L.; Carroll, Thomas E.; Roberts, Adam D.

    2011-09-01

    Cyber friendly fire (FF) is a new concept that has been brought to the attention of Department of Defense (DoD) stakeholders through two workshops that were planned and conducted by the Air Force Research Laboratory (AFRL) and research conducted for AFRL by the Pacific Northwest National Laboratory. With this previous work in mind, we offer a definition of cyber FF as intentional offensive or defensive cyber/electronic actions intended to protect cyber systems against enemy forces or to attack enemy cyber systems, which unintentionally harms the mission effectiveness of friendly or neutral forces. Just as with combat friendly fire, a fundamental need in avoiding cyber FF is to maintain situation awareness (SA). We suggest that cyber SA concerns knowledge of a system's topology (connectedness and relationships of the nodes in a system), and critical knowledge elements such as the characteristics and vulnerabilities of the components that comprise the system (and that populate the nodes), the nature of the activities or work performed, and the available defensive (and offensive) countermeasures that may be applied to thwart network attacks. A training implication is to raise awareness and understanding of these critical knowledge units; an approach to decision aids and/or visualizations is to focus on supporting these critical knowledge units. To study cyber FF, we developed an unclassified security test range comprising a combination of virtual and physical devices that present a closed network for testing, simulation, and evaluation. This network offers services found on a production network without the associated costs of a real production network. Containing enough detail to appear realistic, this virtual and physical environment can be customized to represent different configurations. For our purposes, the test range was configured to appear as an Internet-connected Managed Service Provider (MSP) offering specialized web applications to the general public. The network is essentially divided into a production component that hosts the web and network services, and a user component that hosts thirty employee workstations and other end devices. The organization's network is separated from the Internet by a Cisco ASA network security device that both firewalls and detects intrusions. Business sensitive information is stored in various servers. This includes data comprising thousands of internal documents, such as finance and technical designs, email messages for the organization's employees including the CEO, CFO, and CIO, the organization's source code, and Personally Identifiable client data. Release of any of this information to unauthorized parties would have a significant, detrimental impact on the organization's reputation, which would harm earnings. The valuable information stored in these servers pose obvious points of interest for an adversary. We constructed several scenarios around this environment to support studies in cyber SA and cyber FF that may be run in the test range. We describe mitigation strategies to combat cyber FF including both training concepts and suggestions for decision aids and visualization approaches. Finally, we discuss possible future research directions.

  6. HAZARDS OF THERMAL EXPANSION FOR RADIOLOGICAL CONTAINER ENGULFED IN FIRE

    SciTech Connect (OSTI)

    Donna Post Guillen

    2013-05-01

    Fire accidents pose a serious threat to nuclear facilities. It is imperative that transport casks or shielded containers designed to transport/contain radiological materials have the ability to withstand a hypothetical fire. A numerical simulation was performed for a shielded container constructed of stainless steel and lead engulfed in a hypothetical fire as outlined by 10 CFR §71.73. The purpose of this analysis was to determine the thermal response of the container during and after the fire. The thermal model shows that after 30 minutes of fire, the stainless steel will maintain its integrity and not melt. However, the lead shielding will melt since its temperature exceeds the melting point. Due to the method of construction of the container under consideration, ample void space must be provided to allow for thermal expansion of the lead upon heating and melting, so as to not overstress the weldment.

  7. Rocky Flats Plant Live-Fire Range Risk Analysis Report

    SciTech Connect (OSTI)

    Nicolosi, S.L.; Rodriguez, M.A.

    1994-04-01

    The objective of the Live-Fire Range Risk Analysis Report (RAR) is to provide an authorization basis for operation as required by DOE 5480.16. The existing Live-Fire Range does not have a safety analysis-related authorization basis. EG&G Rocky Flats, Inc. has worked with DOE and its representatives to develop a format and content description for development of an RAR for the Live-Fire Range. Development of the RAR is closely aligned with development of the design for a baffle system to control risks from errant projectiles. DOE 5480.16 requires either an RAR or a safety analysis report (SAR) for live-fire ranges. An RAR rather than a SAR was selected in order to gain flexibility to more closely address the safety analysis and conduct of operation needs for a live-fire range in a cost-effective manner.

  8. Estimation of Rate of Heat Release by Means of Oxygen Consumption Measurements

    E-Print Network [OSTI]

    Womeldorf, Carole

    Estimation of Rate of Heat Release by Means of Oxygen Consumption Measurements Intuitively, the rate of heat release from an unwanted fire is a major indication of the threat of the fire to life and property. This is indeed true, and a reliable mea- surement of a fire's heat release rate was a goal

  9. A Priori Modelling of Fire Test One 

    E-Print Network [OSTI]

    Rein, Guillermo; Torero, Jose L; Jahn, Wolfram; Stern-Gottfried, Jamie; Ryder, Noah L; Desanghere, Sylvain; Lazaro, Mariano; Mowrer, Frederick; Coles, Andrew; Joyeux, Daniel; Alvear, Daniel; Capote, Jorge A; Jowsey, Allan; Reszka, Pedro

    2007-11-14

    An international round-robin study of fire modelling was conducted prior to the Dalmarnock Fire Tests in order to assess the state-of-the-art of fire modelling in real scenarios. The philosophy behind the Dalmarnock Fire ...

  10. Fire at Michael Colliery, Fife 

    E-Print Network [OSTI]

    Stephenson, H. S.

    MINISTRY OF POWER FIRE AT MICHAEL COLLIERY FIFE RE PORT On the causes of, and circumstances attending, the fire which occurred at Michael Colliery, Fife, on 9th September, 1967 by H. S. STEPHENSON, B.Sc., C.Eng., ...

  11. Asymptotics of one-dimensional forest fire processes

    E-Print Network [OSTI]

    Bressaud, Xavier

    2008-01-01

    We consider the so-called one-dimensional forest-fire process. At each site of $\\mathbb{Z}$, a tree appears at rate 1. At each site of $\\mathbb{Z}$ a fire starts at rate $\\lambda>0$, destroying immediately the whole corresponding connected component of trees. We show that when making $\\lambda$ tend to 0, with a correct normalization, the forest-fire process tends to an uniquely defined process, of which we describe precisely the dynamics. The normalization consists of accelerating time by a factor $\\log (1/\\lambda)$ and of compressing space by a factor $\\lambda \\log(1/\\lambda)$. The limit process is quite simple: it can be built using a graphical construction, and can be perfectly simulated. Finally, we derive some asymptotic estimates (when $\\lambda\\to 0$) for the cluster-size distribution of the forest-fire process.

  12. Asymptotics of one-dimensional forest fire processes

    E-Print Network [OSTI]

    Xavier Bressaud; Nicolas Fournier

    2010-11-05

    We consider the so-called one-dimensional forest fire process. At each site of $\\mathbb{Z}$, a tree appears at rate $1$. At each site of $\\mathbb{Z}$, a fire starts at rate ${\\lambda}>0$, immediately destroying the whole corresponding connected component of trees. We show that when ${\\lambda}$ is made to tend to $0$ with an appropriate normalization, the forest fire process tends to a uniquely defined process, the dynamics of which we precisely describe. The normalization consists of accelerating time by a factor $\\log(1/{\\lambda})$ and of compressing space by a factor ${\\lambda}\\log(1/{\\lambda})$. The limit process is quite simple: it can be built using a graphical construction and can be perfectly simulated. Finally, we derive some asymptotic estimates (when ${\\lambda}\\to0$) for the cluster-size distribution of the forest fire process.

  13. Fire protection countermeasures for containment ventilation systems

    SciTech Connect (OSTI)

    Alvares, N.; Beason, D.; Bergman, V.; Creighton, J.; Ford, H.; Lipska, A.

    1980-08-25

    The goal of this project is to find countermeasures to protect High Efficiency Particulate Air (HEPA) filters, in exit ventilation ducts, from the heat and smoke generated by fire. Initially, methods were developed to cool fire-heated air by fine water spray upstream of the filters. It was recognized that smoke aerosol exposure to HEPA filters could also cause disruption of the containment system. Through testing and analysis, several methods to partially mitigate the smoke exposure to the HEPA filters were identified. A continuous, movable, high-efficiency prefilter using modified commercial equipment was designed. The technique is capable of protecting HEPA filters over the total time duration of the test fires. The reason for success involved the modification of the prefiltration media. Commercially available filter media has particle sorption efficiency that is inversely proportional to media strength. To achieve properties of both efficiency and strength, rolling filter media were laminated with the desired properties. The approach was Edisonian, but truncation in short order to a combination of prefilters was effective. The application of this technique was qualified, since it is of use only to protect HEPA filters from fire-generated smoke aerosols. It is not believed that this technique is cost effective in the total spectrum of containment systems, especially if standard fire protection systems are available in the space. But in areas of high-fire risk, where the potential fuel load is large and ignition sources are plentiful, the complication of a rolling prefilter in exit ventilation ducts to protect HEPA filters from smoke aerosols is definitely justified.

  14. FIRE Physics Validation Review Hampton Inn

    E-Print Network [OSTI]

    FIRE Physics Validation Review Agenda Hampton Inn 20260 Goldenrod Lane Germantown, Maryland, US Introduction John Willis 2:15 pm FIRE Overview Dale Meade 3:30 pm FIRE Physics Basis Charles Kessel 5:00 pm Diagnostics for FIRE, Challenges for FIRE and ITER Ken Young 5:30 pm FIRE Engineering Summary Phil

  15. Natural Phenomena Exhibited by Forest Fires

    E-Print Network [OSTI]

    Natural Phenomena Exhibited by Forest Fires J. S. BARROWS U. S. Forest Service ABSTRACT Forest fire phenomena of forest fires is related to the International Symposium topic of Fire Models. Analysis of the behavior of large-scale forest fires and smaller scale experimental fires in forest fuels permits critical

  16. EHSO TRAINING CLASSES Fire Safety Program Training

    E-Print Network [OSTI]

    EHSO TRAINING CLASSES Fire Safety Program Training 1. Fire Safety (60 minutes) Instruction includes an actual fire eperience. 2. Fire Extinguisher Training (30 minutes) A practical demonstration on actual burnable liquid fires. This practical extinguisher training is a critical portion of the fire

  17. Residential Fire Safety Policies Introduction

    E-Print Network [OSTI]

    Johnson Jr.,, Ray

    Residential Fire Safety Policies Introduction University Housing and Campus Code Compliance and Fire Safety at the City University of New York at Queens College in compliance with the Higher Education Opportunity Act (HEOA) have developed an annual fire safety report. This document summarizes

  18. ANNUAL FIRE SAFETY RESIDENCE HALLS

    E-Print Network [OSTI]

    Fernandez, Eduardo

    1 2013 ANNUAL FIRE SAFETY REPORT FOR RESIDENCE HALLS As Required by the Higher Education Opportunity Act (HEOA) #12;2 INTRODUCTION Contents of this annual fire safety report reflect the requirements outlined in the HEOA, which are included in Florida Atlantic University's (FAU) campus fire safety program

  19. Forest fires: from economic assessment

    E-Print Network [OSTI]

    Pettenella, Davide

    1 Forest fires: from economic assessment to governance Laura Secco, Davide Pettenella and Mauro context) Contribute of ongoing research (A model to quantify forest fires costs) Proposal for future research (An ACF approach to stakeholders analysis) Final remarks Background Background - 1 Forest fires

  20. Using Prescribed Fire in Oklahoma

    E-Print Network [OSTI]

    Balasundaram, Balabhaskar "Baski"

    E-927 Using Prescribed Fire in Oklahoma Using Prescribed Fire in Oklahoma Using Prescribed Fire in Oklahoma Oklahoma Cooperative Extension Service Division of Agricultural Sciences and Natural Resources Oklahoma State University in cooperation with USDA Natural Resources Conservation Service, the Oklahoma

  1. Direct fired heat exchanger

    DOE Patents [OSTI]

    Reimann, Robert C. (Lafayette, NY); Root, Richard A. (Spokane, WA)

    1986-01-01

    A gas-to-liquid heat exchanger system which transfers heat from a gas, generally the combustion gas of a direct-fired generator of an absorption machine, to a liquid, generally an absorbent solution. The heat exchanger system is in a counterflow fluid arrangement which creates a more efficient heat transfer.

  2. Oxygen-Fired CO{sub 2} Recycle for Application to Direct CO{sub 2} Capture form Coal-Fired Power Plants

    SciTech Connect (OSTI)

    Thomas Gale

    2010-09-26

    The Southern Research/Southern Company 1 MWth Pilot-Scale Coal-Fired Test Facility was successfully retrofit to fire in either the traditional air-fired mode or with 100% oxygen and recycled flue gas, with a fully integrated feedback and control system, including oxygen and recycled flue gas modulation during startup, transfer, and shutdown, safety and operational interlocks, and data acquisition. A MAXON Staged Oxygen Burner for Oxy-Coal Applications produced a stable flame over a significant range of firing turn-down, staging, and while firing five different U.S. coal types. The MAXON burner design produces lower flame temperatures than for air firing, which will enable (A) Safe operation, (B) Reduction of recycle flow without concern about furnace flame temperatures, and (C) May likely be affective at reducing slagging and fouling in the boiler and super heater at full-scale Power Plants. A CFD model of the Oxy-fired Combustion Research Facility (OCRF) was used to predict the flame geometry and temperatures in the OCRF and make a comparison with the air-fired case. The model predictions were consistent with the experimental data in showing that the MAXON burner fired with oxygen produced lower flame temperatures than the air-fired burner while firing with air.

  3. Enhanced Fire Events Database to Support Fire PRA

    SciTech Connect (OSTI)

    Patrick Baranowsky; Ken Canavan; Shawn St. Germain

    2010-06-01

    Abstract: This paper provides a description of the updated and enhanced Fire Events Data Base (FEDB) developed by the Electric Power Research Institute (EPRI) in cooperation with the U.S. Nuclear Regulatory Commission (NRC). The FEDB is the principal source of fire incident operational data for use in fire PRAs. It provides a comprehensive and consolidated source of fire incident information for nuclear power plants operating in the U.S. The database classification scheme identifies important attributes of fire incidents to characterize their nature, causal factors, and severity consistent with available data. The database provides sufficient detail to delineate important plant specific attributes of the incidents to the extent practical. A significant enhancement to the updated FEDB is the reorganization and refinement of the database structure and data fields and fire characterization details added to more rigorously capture the nature and magnitude of the fire and damage to the ignition source and nearby equipment and structures

  4. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim R.

    2012-01-01

    Rate Structures on Real PV Systems. Preprint, Nationaland the Economics of Solar PV: Could Mandatory Time- of-UsePricing Beneficial to Solar PV in New York City? Prepared

  5. The Impact of Rate Design and Net Metering on the Bill Savings from Distributed PV for Residential Customers in California

    E-Print Network [OSTI]

    Darghouth, Naim

    2010-01-01

    Rate Structures on Real PV Systems. NREL/CP-670-42923.Pricing Beneficial to Solar PV in New York City? PreparedSubstantial Benefit of Solar PV. ” The Electricity Journal,

  6. Existence of a stationary distribution for multi-dimensional infinite volume forest-fire processes

    E-Print Network [OSTI]

    Stahl, Alice

    2012-01-01

    Consider the following forest-fire process on a connected graph. Each site of the graph can be either occupied or vacant. A vacant site becomes occupied with rate 1. A site is ignited with rate lambda, and its whole occupied cluster burns instantaneously. The purpose of this paper is to show the existence of a stationary distribution for forest-fire processes on Z^d, for d >= 2. We define a distribution as a limit of a sequence of invariant distributions of finite volume forest-fire processes, and then show it is a stationary distribution for forest-fire processes on Z^d, d>=2.

  7. UF{sub 6} cylinder fire test

    SciTech Connect (OSTI)

    Park, S.H. [Oak Ridge K-25 Site, Oak Ridge, TN (United States)

    1991-12-31

    With the increasing number of nuclear reactors for power generation, there is a comparable increase in the amount of UF{sub 6} being transported. Likewise, the probability of having an accident involving UF{sub 6}-filled cylinders also increases. Accident scenarios which have been difficult to assess are those involving a filled UF{sub 6} cylinder subjected to fire. A study is underway at the Oak Ridge K-25 Site, as part of the US DOE Enrichment Program, to provide empirical data and a computer model that can be used to evaluate various cylinder-in-fire scenarios. It is expected that the results will provide information leading to better handling of possible fire accidents as well as show whether changes should be made to provide different physical protection during shipment. The computer model being developed will be capable of predicting the rupture of various cylinder sizes and designs as well as the amount of UF{sub 6}, its distribution in the cylinder, and the conditions of the fire.

  8. Fire Behavior Modeling - Experiment on Surface Fire Transition to the Elevated Live Fuel

    E-Print Network [OSTI]

    Omodan, Sunday

    2015-01-01

    Scientific Perspectives. Austin Fire Department, EngineeringCombustion Fundamentals of Fire, Ed. G. Cox Academic Press,Finney, M. A. FARSITE: Fire Area Simulator-Model Development

  9. The Tropical Forest and Fire Emissions Experiment: overview and airborne fire emission factor measurements

    E-Print Network [OSTI]

    2007-01-01

    W. M. : The tropical forest and fire emissions experiment:Physics The Tropical Forest and Fire Emissions Experiment:A. : The tropical forest and fire emissions experiment:

  10. Simulating Historic Landscape Patterns of Fire in the Southern Appalachian Mountains: Implications for Fire History and Management 

    E-Print Network [OSTI]

    Gass, Ellen R

    2014-05-21

    -suppression fire regime is needed. Fire frequency and seasonality can be determined from physical fire records, such as fire scars, but fire size, fire cycle, ignition density, and ignition source are more difficult to ascertain. Using FARSITE, a spatially explicit...

  11. Are Forest Fires Predictable?

    E-Print Network [OSTI]

    K. Malarz; S. Kaczanowska; K. Kulakowski

    2002-04-23

    Dynamic mean field theory is applied to the problem of forest fires. The starting point is the Monte Carlo simulation in a lattice of million cells. The statistics of the clusters is obtained by means of the Hoshen--Kopelman algorithm. We get the map $p_n\\to p_{n+1}$, where $p_n$ is the probability of finding a tree in a cell, and $n$ is the discrete time. We demonstrate that the time evolution of $p$ is chaotic. The arguments are provided by the calculation of the bifurcation diagram and the Lyapunov exponent. The bifurcation diagram reveals several windows of stability, including periodic orbits of length three, five and seven. For smaller lattices, the results of the iteration are in qualitative agreement with the statistics of the forest fires in Canada in years 1970--2000.

  12. Design and implementation of a high data rate wireless system using Low-Density Parity-Check codes 

    E-Print Network [OSTI]

    Bhatt, Tejas Maheshbhai

    2000-01-01

    . Various decoding algorithms for LDPC codes are implemented and complexity v/s bit error rate (BER) trade off is studied. The goal is to evaluate LDPC codes as a suitable candidate for the forward error correction in the next generation wireless systems...

  13. Fire suppressing apparatus

    DOE Patents [OSTI]

    Buttrey, Kenneth E. (Northridge, CA)

    1982-11-02

    Apparatus for smothering a liquid sodium fire comprises a pan, a perforated cover on the pan, and tubes depending from the cover and providing communication between the interior of the pan and the ambient atmosphere through the perforations in the cover. Liquid caught in the pan rises above the lower ends of the tubes and thus serves as a barrier which limits the amount of air entering the pan.

  14. Calculating Fired Heater Efficiency 

    E-Print Network [OSTI]

    Harriz, J. T.; Ritter, E. L.

    1986-01-01

    - The primary components of fuel are carbon and hydrogen. In the chemistry of combustion, hydrogen reacts with oxygen to form water vapor. The Higher Heating Value is the heat delivered by cooling all the products of combustion to their initial temperature... load. Combustibles losses are highly dependent on fuel type. Natural gas and No. 2 fuel oil are easily fired and flue gas residual combustibles are usually negligible. Coal, biomass and trash burners will usually have measurable unburned carbon...

  15. FIRE Design Review Magnet System Structural Analyses

    E-Print Network [OSTI]

    304 Stainless Steel (Bar,annealed) 404 1721 282 1522 234 640 Primary Stress Allowables for Materials

  16. APPLICATION OF FAULT TREE ANALYSIS TO IGNITION OF FIRE

    E-Print Network [OSTI]

    Teresa Ling, W.C.

    2011-01-01

    Fig. 11 The Probability of Each Fire Scenario in a Kitchen ~Globerson, S. (1971). Berkeley Fire Incident Survey Initial1977. Evaluation of the Fire Hazard Household Fire Survey.

  17. Global fire emissions and the contribution of deforestation, savanna, forest, agricultural, and peat fires (1997-2009)

    E-Print Network [OSTI]

    2010-01-01

    John- stone, J. F. : Quantifying fire severity, carbon, andfrom Canadian forest fires, 1959– 1999, Can. J. Forestwildland fires1, Int. J. Wildland Fire, 16, 593–606, doi:

  18. Cross Plains, Texas Wildland Fire Case Study

    E-Print Network [OSTI]

    was decimated by this fire. Like so many fire seasons across the western U.S., homes, communities and lives the interactions of the fire environment and the community led to the destruction of homes, property and lives. Rich Gray ­ Urban Wildland Interface State Coordinator Mike Dunivan ­ Fire Weather/Fire Behavior

  19. Fire exposure of empty 30B cylinders

    SciTech Connect (OSTI)

    Ziehlke, K.T. [MJB Technical Associates, Inc., Knoxville, TN (United States)

    1991-12-31

    Cylinders for UF{sub 6} handling, transport, and storage are designed and built as unfired pressure vessels under ASME Boiler and Pressure Vessel Code criteria and standards. They are normally filled and emptied while UF{sub 6} is in its liquid phase. Transport cylinders such as the Model 30B are designed for service at 200 psi and 250{degrees}F, to sustain the process conditions which prevail during filling or emptying operations. While in transport, however, at ambient temperature the UF{sub 6} is solid, and the cylinder interior is well below atmospheric pressure. When the cylinders contain isotopically enriched product (above 1.0 percent U-235), they are transported in protective overpacks which function to guard the cylinders and their contents against thermal or mechanical damage in the event of possible transport accidents. Two bare Model 30B cylinders were accidentally exposed to a storage warehouse fire in which a considerable amount of damage was sustained by stored materials and the building structure, as well as by the cylinder valves and valve protectors. The cylinders were about six years old, and had been cleaned, inspected, hydrotested, and re-certified for service, but were still empty at the time of the fire. The privately-owned cylinders were transferred to DOE for testing and evaluation of the fire damage.

  20. Fire Department, City of New York Fire SaFety education

    E-Print Network [OSTI]

    Schindler, Christian

    Fire Department, City of New York Fire SaFety education reSidential apartment Building Fire SaFety #7 Bill De Blasio, Mayor Daniel A. Nigro, Fire Commissioner Fire safety begins in your own apartment! Is your family fire safe? Protect yourself, your family and your neighbors. T here are special areas

  1. FireWatch: G.I.S.-assisted Wireless Sensor Networks for Forest Fires

    E-Print Network [OSTI]

    Shahabi, Cyrus

    FireWatch: G.I.S.-assisted Wireless Sensor Networks for Forest Fires Panayiotis G. Andreou, George and camera-based systems, are currently the predominant methods for detecting forest fires. Our study has-based approaches, FireWatch is able to detect forest fires more accurately and forecast the forest fire danger more

  2. Energy Management Through Innovative Rates 

    E-Print Network [OSTI]

    Williams, M. L.

    1982-01-01

    of energy efficiency in the industrial sector and specific rate design alternatives for doing so....

  3. Fire Risk Assessments -Fire Extinguisher Provision Strategy General Areas

    E-Print Network [OSTI]

    Sussex, University of

    Foam (AFFF) extinguishers. Electrical fires can be tackled using Carbon Dioxide (CO2) fire the potential severity of these outcomes to the user. Therefore, AFFF (6 litre) and CO2 (2 kg) will be the type that all plant rooms should have CO2 extinguishers located at any entrances to the plant room. Other

  4. Sandia Energy - Fire Science

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach Home RoomPreservation of Fe(II) byMultidayAlumniProjectsCyberNotLEDPhaseFacilitiesFire Science Home

  5. Fire Safety Committee Meeting Minutes- May 2014

    Broader source: Energy.gov [DOE]

    DOE Fire Safety Committee Meeting Minutes, May, 2014 Topics included discussions on Fire modeling, revisions to DOE regulations and other important items relating to DOE and Fire Safety Community.

  6. Health Consequences of Forest Fires in Indonesia

    E-Print Network [OSTI]

    Frankenberg, Elizabeth; McKee, Douglas; Thomas, Duncan

    2004-01-01

    to Lung Health of Haze From Forest Fires: The SingaporeJim, C.Y. 1999. “The Forest Fires in Indonesia 1997-1998:A Study of the 1997 Forest Fires in South East Asia Using

  7. Prescribed Fire is Cool on Florida Highway

    E-Print Network [OSTI]

    Caster, Jeff; McBurney, Willson; Farley, Patricia; Rodriguez, Rose; Green, Lane; McGorty, Kevin

    2007-01-01

    Only you can prevent forest fires! For all our lives we’veYou can’t prevent forest fires. We can, however, preventcan prevent wildfires. ” Forest fires will occur naturally,

  8. Using neutrons to fight forest fires

    E-Print Network [OSTI]

    Egbert, Hal; Walker, Ronald; Flocchini, R.

    2006-01-01

    USING NEUTRONS TO FIGHT FOREST FIRES Hal Egbert, Ronaldretardant to the scene of forest fires. One system that goesretardant to the scene of forest fires. MAFFS is the acronym

  9. Forwardly-placed firearm fire control assembly

    DOE Patents [OSTI]

    Frickey, Steven J. (Rigby, ID)

    2001-12-22

    A firearm fire control assembly for disposition in a forwardly placed support-hand operative relationship within a firearm having a combination of a firing pin and a firearm hammer adapted to engage and fire a cartridge, a sear assembly to alternately engage and disengage the combination of the firearm hammer and firing pin, and a trigger assembly including a movable trigger mechanism that is operable to engage the sear assembly to cause the firearm hammer firing pin combination to fire the firearm, a fire control assembly including a fire control depression member and a fire control rod operably connected to the depression member, and being positioned in a forward disposition disposed within a forestock of the firearm, and the depression member adapted to be operably engaged and depressed by the user's conventional forwardly placed support hand to maneuver the fire control rod to provide firing control of the firing of the firearm.

  10. CONDENSING ECONOMIZERS FOR SMALL COAL-FIRED BOILERS AND FURNACES PROJECT REPORT - JANUARY 1994

    SciTech Connect (OSTI)

    BUTCHER,T.A.

    1994-01-04

    Condensing economizers increase the thermal efficiency of boilers by recovering sensible and latent heat from exhaust gas. These economizers are currently being used commercially for this purpose in a wide range of applications. Performance is dependent upon application-specific factors affecting the utility of recovered heat. With the addition of a condensing economizer boiler efficiency improvements up to 10% are possible. Condensing economizers can also capture flue gas particulates. In this work, the potential use of condensing economizers for both efficiency improvement and control of particulate emissions from small, coal water slurry-fired boilers was evaluated. Analysis was done to predict heat transfer and particulate capture by mechanisms including: inertial impaction, interception, diffusion, thermophoretic forces, and condensation growth. Shell-and-tube geometries were considered with flue gas on the outside of Teflon-covered tubes. Experimental studies were done with both air- and water-cooled economizers refit to a small boiler. Two experimental arrangements were used including oil-firing with injection of flyash upstream of the economizer and direct coal water slurry firing. Firing rates ranged from 27 to 82 kW (92,000 to 280,000 Btu/hr). Inertial impaction was found to be the most important particulate capture mechanism and removal efficiencies to 95% were achieved. With the addition of water sprays directly on the first row of tubes, removal efficiencies increased to 98%. Use of these sprays adversely affects heat recovery. Primary benefits of the sprays are seen to be the addition of small impaction sites and future design improvements are suggested in which such small impacts are permanently added to the highest velocity regions of the economizer. Predicted effects of these added impactors on particulate removal and pressure drop are presented.

  11. The Measurement of Trace Emissions and Combustion Characteristics for a Mass Fire

    E-Print Network [OSTI]

    fuels, temperature profiles, and fluid motions within and adjacent to large fires. Feedback mechanisms and burning condition of the fuel. Measurements made by satellites or aircraft can be used to estimate areas actual amounts of fuel consumed, the rate of fuel consumption, and carbon and heat release by the fire

  12. Experimental Design for a Macrofoam-Swab Study Relating the Recovery Efficiency and False Negative Rate to Low Concentrations of Two Bacillus anthracis Surrogates on Four Surface Materials

    SciTech Connect (OSTI)

    Piepel, Gregory F.; Hutchison, Janine R.

    2014-12-05

    This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam-swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (culture and polymerase chain reaction) will be used. Only one previous study has investigated how the false negative rate depends on test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completing gaps in the available information on the performance of macrofoam-swab sampling at low concentrations.

  13. Test One: The ‘Uncontrolled’ Fire 

    E-Print Network [OSTI]

    Abecassis Empis, Cecilia; Cowlard, Adam; Welch, Stephen; Torero, Jose L

    2007-11-14

    The first of the Dalmarnock Fire Tests was a post-flashover compartment fire experiment held on July 25th, 2006, in a two-bedroom single-family flat on the 4th floor of the 23- storey reinforced concrete tower in Dalmarnock, ...

  14. Quantifying chaotic dynamics from integrate-and-fire processes

    SciTech Connect (OSTI)

    Pavlov, A. N.; Pavlova, O. N.; Mohammad, Y. K.; Kurths, J.

    2015-01-15

    Characterizing chaotic dynamics from integrate-and-fire (IF) interspike intervals (ISIs) is relatively easy performed at high firing rates. When the firing rate is low, a correct estimation of Lyapunov exponents (LEs) describing dynamical features of complex oscillations reflected in the IF ISI sequences becomes more complicated. In this work we discuss peculiarities and limitations of quantifying chaotic dynamics from IF point processes. We consider main factors leading to underestimated LEs and demonstrate a way of improving numerical determining of LEs from IF ISI sequences. We show that estimations of the two largest LEs can be performed using around 400 mean periods of chaotic oscillations in the regime of phase-coherent chaos. Application to real data is discussed.

  15. EMERGENCY PROCEDURES POLICE/FIRE/MEDICAL EMERGENCY DIAL: 716-645-2222

    E-Print Network [OSTI]

    Krovi, Venkat

    EMERGENCY PROCEDURES POLICE/FIRE/MEDICAL EMERGENCY DIAL: 716-645-2222 For Non-Emergency Hazardous IMMEDIATELY when a fire alarm is activated, even if there are no obvious signs of an emergency! DO NOT use by emergency personnel and respond to location designated by your building coordinator outside the structure

  16. The role of thermal radiation on the initiation of flashover in a compartment fire

    E-Print Network [OSTI]

    Yuen, Walter W.

    . For example, three criteria were commonly accepted by the fire safety community as conditions for flashover them as a basis for fire safety design. Over the years, numerical and theoretical studies of flashover) flame coming out of openings. While these criteria are generally supported by experi- mental observation

  17. Reliability study of an emerging fire suppression system

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Miller, David A.; Rossati, Lyric M.; Fritz, Nathan K.; Cournoyer, Michael E.; Granzow, Howard N.

    2015-02-07

    Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Plutonium gloveboxes are known to present harsh environmental conditions for polymer materials, these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. The primary component of interest in self-contained fire extinguishers is the nylon 6-6 machined tube that comprises the main body of the system.Thermo-mechanical modeling and characterization of nylon 6-6 for use in plutonium glovebox applications has been carried out. Data has been generated regarding property degradation leading to poor, or reduced, engineering performancemore »of nylon 6-6 components. In this study, nylon 6-6 tensile specimens conforming to the casing of self-contained fire extinguisher systems have been exposed to hydrochloric, nitric, and sulfuric acids. This information was used to predict the performance of a load bearing engineering component comprised of nylon 6-6 and designed to operate in a consistent manner over a specified time period. The study provides a fundamental understanding of the engineering performance of the fire suppression system and the effects of environmental degradation due to acid exposure on engineering performance. Data generated help identify the limitations of self-contained fire extinguishers. No critical areas of concern for plutonium glovebox applications of nylon 6-6 have been identified when considering exposure to mineral acid.« less

  18. Development of custom fire behavior fuel models from FCCS fuelbeds for the Savannah River fuel assessment project.

    SciTech Connect (OSTI)

    Scott, Joe, H.

    2009-07-23

    The purpose of this project is to create fire behavior fuel models that replicate the fire behavior characteristics (spread rate and fireline intensity) produced by 23 candidate FCCS fuelbeds developed for the Savannah River National Wildlife Refuge. These 23 fuelbeds were created by FERA staff in consultation with local fuel managers. The FCCS produces simulations of surface fire spread rate and flame length (and therefore fireline intensity) for each of these fuelbeds, but it does not produce maps of those fire behavior characteristics or simulate fire growth—those tasks currently require the use of the FARSITE and/or FlamMap software systems. FARSITE and FlamMap do not directly use FCCS fuelbeds, but instead use standard or custom fire behavior fuel models to describe surface fuel characteristics for fire modeling. Therefore, replicating fire growth and fire behavior potential calculations using FCCS?simulated fire characteristics requires the development of custom fuel models that mimic, as closely as possible, the fire behavior characteristics produced by the FCCS for each fuelbed, over a range of fuel moisture and wind speeds.

  19. 5th Symposium on Fire and Forest Meteorology and the 2nd International Wildland Fire Ecology and Fire Management Congress

    E-Print Network [OSTI]

    Fried, Jeremy S.

    More 5th Symposium on Fire and Forest Meteorology and the 2nd International Wildland Fire Ecology and Fire Management Congress Monday, 17 November 2003 Fire severity classification: uses and abuses Theresa B. Jain, USDA Forest Service, Moscow, Idaho, ID; and R. T. Graham Burn severity (also referred

  20. Prescriptive vs. performance based cook-off fire testing.

    SciTech Connect (OSTI)

    Nakos, James Thomas; Tieszen, Sheldon Robert; Erikson, William Wilding; Gill, Walter; Blanchat, Thomas K.

    2010-07-01

    In the fire safety community, the trend is toward implementing performance-based standards in place of existing prescriptive ones. Prescriptive standards can be difficult to adapt to changing design methods, materials, and application situations of systems that ultimately must perform well in unwanted fire situations. In general, this trend has produced positive results and is embraced by the fire protection community. The question arises as to whether this approach could be used to advantage in cook-off testing. Prescribed fuel fire cook-off tests have been instigated because of historical incidents that led to extensive damage to structures and loss of life. They are designed to evaluate the propensity for a violent response. The prescribed protocol has several advantages: it can be defined in terms of controllable parameters (wind speed, fuel type, pool size, etc.); and it may be conservative for a particular scenario. However, fires are inherently variable and prescribed tests are not necessarily representative of a particular accident scenario. Moreover, prescribed protocols are not necessarily adaptable and may not be conservative. We also consider performance-based testing. This requires more knowledge and thought regarding not only the fire environment, but the behavior of the munitions themselves. Sandia uses a performance based approach in assuring the safe behavior of systems of interest that contain energetic materials. Sandia also conducts prescriptive fire testing for the IAEA, NRC and the DOT. Here we comment on the strengths and weakness of both approaches and suggest a path forward should it be desirable to pursue a performance based cook-off standard.

  1. A Factsheet on Holiday Fire Prevention

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach HomeA Better Anode Design to Improve Lithium-Ion Batteries Print Lithium-ion batteriesAyou|ach year fires

  2. FIRE SAFETY REPORT ENVIRONMENTAL HEALTH & SAFETY SERVICES

    E-Print Network [OSTI]

    Hong, Don

    FIRE SAFETY REPORT 2014 ENVIRONMENTAL HEALTH & SAFETY SERVICES #12;1 | M T S U F I R E S A F E T Y R E P O R T FIRE SAFETY REPORT TABLE OF CONTENTS INTRODUCTION 2 RESPONSIBILITIES AND DUTIES OF THE MTSU FIRE MARSHAL 2 GENERAL 3 SMOKING POLICY 3 CLASS A COMBUSTIBLES 4 CLASS B COMBUSTIBLES 4 FIRE

  3. WILDLAND FIRE SUSCEPTIBILITY ANALYSIS APPENDIX A

    E-Print Network [OSTI]

    APPENDIX A WILDLAND FIRE SUSCEPTIBILITY ANALYSIS #12;APPENDIX A WILDLAND FIRE SUSCEPTIBILITY ANALYSIS (From Wildland Fire Risk Assessment for the Lake Tahoe Region, 10/28/99, Completed For The USDA-Forest Service, Lake Tahoe Basin Management Unit, By Jones and Stokes Associates, Sacramento, California, Fire

  4. Fire Safety Report 2013 Rensselaer Polytechnic Institute

    E-Print Network [OSTI]

    Linhardt, Robert J.

    Fire Safety Report 2013 Rensselaer Polytechnic Institute 110 Eighth Street Troy, NY 12180 #12;TABLE OF CONTENTS From the Department of Environmental Health and Safety Page 1 Annual Fire Report Page 2 Reported Fires Page 5 Fire Safety Systems Page 7 #12;From the Department of Environmental Health and Safety (EH

  5. FIRE Project Action Plan in Response to

    E-Print Network [OSTI]

    1 FIRE Project Action Plan in Response to Next Step Options Program Advisory Committee Report (PAC1) FIRE Mission: Finding F1-1: PAC-1 felt that the FIRE mission statement, "Attain, explore, understand states the scientific direction and objectives of the FIRE program, but that the mission statement does

  6. 8, 42214266, 2008 Tropical forest fire

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    ACPD 8, 4221­4266, 2008 Tropical forest fire emissions R. J. Yokelson et al. Title Page Abstract Chemistry and Physics Discussions The tropical forest and fire emissions experiment: laboratory fire Publications on behalf of the European Geosciences Union. 4221 #12;ACPD 8, 4221­4266, 2008 Tropical forest fire

  7. 7, 69036958, 2007 Tropical Forest fire

    E-Print Network [OSTI]

    Boyer, Edmond

    ACPD 7, 6903­6958, 2007 Tropical Forest fire emissions R. J. Yokelson et al. Title Page Abstract Discussions The Tropical Forest and fire emissions experiment: overview and airborne fire emission factor Forest Service, Fire Sciences Laboratory, Missoula, MT, USA Received: 4 May 2007 ­ Accepted: 10 May 2007

  8. GREAT PLAINS INTERSTATE FOREST FIRE COOPERATIVE

    E-Print Network [OSTI]

    GREAT PLAINS INTERSTATE FOREST FIRE COMPACT COOPERATIVE ANNUAL OPERATING PLAN 2011 #12;Great Plains Interstate Forest Fire Compact Page 2 of 31 2011 Great Plains Forest Fire Compact AOP Table of Contents I. Intentionally Left Blank 28 K. Public Law 110-79 29 #12;Great Plains Interstate Forest Fire Compact Page 3 of 31

  9. FIRE Action Plan to Respond to Next Step Options

    E-Print Network [OSTI]

    .2: Progress in implementing the action plan is limited to date. Some significant progress was made the performance of FIRE under the ITER98(y,2) confinement scaling law. Small perturbations around the design point the community (specifically #12;2 chosen from among the participants of the recent UFA Burning Plasma Science

  10. Impacts of climate change on fire activity and fire management in the circumboreal forest

    E-Print Network [OSTI]

    Turetsky, Merritt

    Impacts of climate change on fire activity and fire management in the circumboreal forest M I K E F Lansing, MI 48824, USA Abstract Forest fires are a significant and natural element of the circumboreal forest. Fire activity is strongly linked to weather, and increased fire activity due to climate change

  11. Introduction to FireGrid 

    E-Print Network [OSTI]

    Welch, Stephen; Usmani, Asif; Upadhyay, Rochan; Berry, Dave; Potter, Stephen; Torero, Jose L

    2007-11-14

    FireGrid is an ambitious and innovative project, seeking to develop the technology to support a new way of managing emergency response in the modern built environment. Specific novel aspects include the integration of ...

  12. Test Two: The ‘Controlled Fire’ 

    E-Print Network [OSTI]

    Cowlard, Adam; Steinhaus, Thomas; Abecassis Empis, Cecilia; Torero, Jose L

    2007-11-14

    The main objective of Test Two was to demonstrate the effectiveness of ventilation changes and smoke management on the growth of a compartment fire and to display the potential for these techniques to be incorporated ...

  13. Coal-fired power materials

    SciTech Connect (OSTI)

    Viswanathan, V.; Purgert, R.; Rawls, P. [Electric Power Research Institute, Palo Alto, CA (United States)

    2008-08-15

    Advances in materials technologies over the last decade that is allowing coal-fired power plants to be built with higher efficiencies than the current generation are described. 2 figs., 2 tabs.

  14. Model Fire Protection Assessment Guide

    Office of Energy Efficiency and Renewable Energy (EERE)

    This Assessment guide covers the implementation of the DOE's responsibility of assuring that DOE and the DOE Contractors have established Fire Protection Programs that are at the level required for the area being assessed.

  15. Building & Fire Assist Director

    E-Print Network [OSTI]

    Buren Physical Safety (Electrical, Confined Space, Machinery, Fall Prevention) Construction & Remodel Design Review Lab / Shop Safety Surveys Regulated Building Materials Public Health (Food, Water, Pests

  16. Experimental Design for a Macrofoam Swab Study Relating the Recovery Efficiency and False Negative Rate to Low Concentrations of Two Bacillus anthracis Surrogates on Four Surface Materials

    SciTech Connect (OSTI)

    Piepel, Gregory F.; Hutchison, Janine R.

    2014-04-16

    This report describes the experimental design for a laboratory study to quantify the recovery efficiencies and false negative rates of a validated, macrofoam swab sampling method for low concentrations of Bacillus anthracis Sterne (BAS) and Bacillus atrophaeus (BG) spores on four surface materials (stainless steel, glass, vinyl tile, plastic light cover panel). Two analytical methods (plating/counting and polymerase chain reaction) will be used. Only one previous study has investigated false negative as a function of affecting test factors. The surrogates BAS and BG have not been tested together in the same study previously. Hence, this study will provide for completing gaps in the available information on the performance of macrofoam swab sampling at low concentrations.

  17. Characterization of Oxy-combustion Impacts in Existing Coal-fired Boilers

    SciTech Connect (OSTI)

    Bradley Adams; Andrew Fry; Constance Senior; Hong Shim; Huafeng Wang; Jost Wendt; Christopher Shaddix

    2009-06-30

    This report summarizes Year 1 results of a research program designed to use multi-scale experimental studies and fundamental theoretical models to characterize and predict the impacts of retrofit of existing coal-fired utility boilers for oxy-combustion. Through the course of Year 1 activities, great progress was made toward understanding the issues associated with oxy-combustion retrofit of coal-fired boilers. All four Year 1 milestones and objectives have been, or will be, completed on schedule and within budget. Progress in the four milestone areas may be summarized as follows: • University of Utah has performed size segregated ash composition measurements in the Oxy-Fuel Combustor (OFC). These experiments indicate that oxy-combustion retrofit may impact ash aerosol mineral matter composition. Both flame temperature and flue gas composition have been observed to influence the concentration of calcium, magnesium and iron in the fine particulate. This could in turn impact boiler fouling and slagging. • Sandia National Labs has shown that char oxidation rate is dependent on particle size (for sizes between 60 and 100 microns) by performing fundamental simulations of reacting char particles. These predictions will be verified by making time-resolved optical measurements of char particle temperature, velocity and size in bench-scale experiments before the end of Year 1. • REI and Siemens have completed the design of an oxy-research burner that will be mounted on University of Utah’s pilot-scale furnace, the L1500. This burner will accommodate a wide range of O2, FGR and mixing strategies under conditions relevant for utility boiler operation. Through CFD modeling of the different burner designs, it was determined that the key factor influencing flame stabilization location is particle heat-up rate. The new oxy-research burner and associated equipment is scheduled for delivery before the end of Year 1. • REI has completed a literature survey of slagging and fouling mechanisms in coal-fired power plants to understand key issues influencing these deposition regimes and infer their behavior under oxy-fired conditions. Based on the results of this survey, an algorithm for integrating slagging predictions into CFD models was outlined. This method accounts for ash formation, particle impaction and sticking, deposit growth and physical properties and impact of the deposit on system flow and heat transfer. A model for fouling in the back pass has also been identified which includes vaporization of sodium, deposition of sodium sulfate on fly ash particles and tube surfaces, and deposit growth rate on tubes. In Year 1, REI has also performed a review of the literature describing corrosion in order to understand the behavior of oxidation, sulfidation, chloridation, and carburization mechanisms in air-fired and oxy-combustion systems. REI and Vattenfall have met and exchanged information concerning oxy-coal combustion mechanisms for CFD simulations currently used by Vattenfall. In preparation for Year 2 of this program, two coals (North Antelope PRB, Western bituminous) have been ordered, pulverized and delivered to the University of Utah and Sandia National Labs. Materials for the corrosion experiments have been identified, suppliers located, and a schedule for equipment fabrication and shakedown has been established. Finally, a flue gas recycle system has been designed and is being constructed for the OFC.

  18. Audit Report, "Fire Protection Deficiencies at Los Alamos National Laboratory"

    SciTech Connect (OSTI)

    None

    2009-06-01

    The Department of Energy's Los Alamos National Laboratory (Los Alamos) maintains some of the Nation's most important national security assets, including nuclear materials. Many of Los Alamos' facilities are located in close proximity to one another, are occupied by large numbers of contract and Federal employees, and support activities ranging from nuclear weapons design to science-related activities. Safeguarding against fires, regardless of origin, is essential to protecting employees, surrounding communities, and national security assets. On June 1, 2006, Los Alamos National Security, LLC (LANS), became the managing and operating contractor for Los Alamos, under contract with the Department's National Nuclear Security Administration (NNSA). In preparation for assuming its management responsibilities at Los Alamos, LANS conducted walk-downs of the Laboratory's facilities to identify pre-existing deficiencies that could give rise to liability, obligation, loss or damage. The walk-downs, which identified 812 pre-existing fire protection deficiencies, were conducted by subject matter professionals, including fire protection experts. While the Los Alamos Site Office has overall responsibility for the effectiveness of the fire protection program, LANS, as the Laboratory's operating contractor, has a major, day-to-day role in minimizing fire-related risks. The issue of fire protection at Los Alamos is more than theoretical. In May 2000, the 'Cerro Grande' fire burned about 43,000 acres, including 7,700 acres of Laboratory property. Due to the risk posed by fire to the Laboratory's facilities, workforce, and surrounding communities, we initiated this audit to determine whether pre-existing fire protection deficiencies had been addressed. Our review disclosed that LANS had not resolved many of the fire protection deficiencies that had been identified in early 2006: (1) Of the 296 pre-existing deficiencies we selected for audit, 174 (59 percent) had not been corrected; and, (2) A substantial portion of the uncorrected deficiencies, 86 (49 percent) were considered by the walk-down teams to be significant enough to warrant compensatory actions until the deficiency was corrected or was tracked to closure through implementation of corrective actions. Further, we found that 32 of the significant deficiencies had been closed by the previous Los Alamos contractor, prior to LANS assuming responsibility for operation of the Laboratory, even though the deficiencies had not been corrected. A fire protection expert provided technical support during the audit. As an example of uncorrected problems, LANS had not resolved, by performing periodic tests, a deficiency identified in 2006 regarding a kitchen hood fire suppression system in a facility located within the Los Alamos Neutron Science Center. Such systems are required to be tested twice a year by the National Fire Protection Association standard, a standard that had been adopted by Department of Energy under DOE Order 420.1B. Yet, in 2006, the LANS walk-down team recognized that this system had not been inspected since May 2004 and noted that deficient suppression systems could result in significantly high levels of property damage and loss. After we brought this issue to management's attention on February 6, 2009, LANS officials stated that the Laboratory would correct this deficiency. As with the problems involving the fire suppression system, we observed that LANS had not always corrected life safety deficiencies involving building exits at one of its primary facilities. This included providing a secondary emergency exit for a building with occupants on multiple floor levels. LANS had removed personnel from the third floor and improved the sprinkler system of the facility, but it had still not provided a secondary exit for personnel on the second floor by the time we completed our review. NNSA has since stated that this fire protection issue will be completely addressed by relocating personnel from the second floor. Perhaps most serious, our testing revealed that a number of deficien

  19. Incipient fire detection system

    DOE Patents [OSTI]

    Brooks, Jr., William K. (Newport News, VA)

    1999-01-01

    A method and apparatus for an incipient fire detection system that receives gaseous samples and measures the light absorption spectrum of the mixture of gases evolving from heated combustibles includes a detector for receiving gaseous samples and subjecting the samples to spectroscopy and determining wavelengths of absorption of the gaseous samples. The wavelengths of absorption of the gaseous samples are compared to predetermined absorption wavelengths. A warning signal is generated whenever the wavelengths of absorption of the gaseous samples correspond to the predetermined absorption wavelengths. The method includes receiving gaseous samples, subjecting the samples to light spectroscopy, determining wavelengths of absorption of the gaseous samples, comparing the wavelengths of absorption of the gaseous samples to predetermined absorption wavelengths and generating a warning signal whenever the wavelengths of absorption of the gaseous samples correspond to the predetermined absorption wavelengths. In an alternate embodiment, the apparatus includes a series of channels fluidically connected to a plurality of remote locations. A pump is connected to the channels for drawing gaseous samples into the channels. A detector is connected to the channels for receiving the drawn gaseous samples and subjecting the samples to spectroscopy. The wavelengths of absorption are determined and compared to predetermined absorption wavelengths is provided. A warning signal is generated whenever the wavelengths correspond.

  20. Designing Equitable Merit Rating Plans

    E-Print Network [OSTI]

    Ferreira, Joseph Jr.

    Throughout the United States it is common practice for automobile insurance premiums for a particular policy to vary depending upon the driver class and geographic location of the policyholder as well as the type and number ...

  1. Error-eliminating rapid ultrasonic firing

    DOE Patents [OSTI]

    Borenstein, Johann (Ann Arbor, MI); Koren, Yoram (Ann Arbor, MI)

    1993-08-24

    A system for producing reliable navigation data for a mobile vehicle, such as a robot, combines multiple range samples to increase the "confidence" of the algorithm in the existence of an obstacle. At higher vehicle speed, it is crucial to sample each sensor quickly and repeatedly to gather multiple samples in time to avoid a collision. Erroneous data is rejected by delaying the issuance of an ultrasonic energy pulse by a predetermined wait-period, which may be different during alternate ultrasonic firing cycles. Consecutive readings are compared, and the corresponding data is rejected if the readings differ by more than a predetermined amount. The rejection rate for the data is monitored and the operating speed of the navigation system is reduced if the data rejection rate is increased. This is useful to distinguish and eliminate noise from the data which truly represents the existence of an article in the field of operation of the vehicle.

  2. Error-eliminating rapid ultrasonic firing

    DOE Patents [OSTI]

    Borenstein, J.; Koren, Y.

    1993-08-24

    A system for producing reliable navigation data for a mobile vehicle, such as a robot, combines multiple range samples to increase the confidence'' of the algorithm in the existence of an obstacle. At higher vehicle speed, it is crucial to sample each sensor quickly and repeatedly to gather multiple samples in time to avoid a collision. Erroneous data is rejected by delaying the issuance of an ultrasonic energy pulse by a predetermined wait-period, which may be different during alternate ultrasonic firing cycles. Consecutive readings are compared, and the corresponding data is rejected if the readings differ by more than a predetermined amount. The rejection rate for the data is monitored and the operating speed of the navigation system is reduced if the data rejection rate is increased. This is useful to distinguish and eliminate noise from the data which truly represents the existence of an article in the field of operation of the vehicle.

  3. Dynamics of fire plumes and smoke clouds associated with peat and deforestation fires in Indonesia

    E-Print Network [OSTI]

    Tosca, M. G; Randerson, J. T; Zender, C. S; Nelson, D. L; Diner, D. J; Logan, J. A

    2011-01-01

    stereo heights of grassland fire smoke plumes in Australia,of 14 D08207 TOSCA ET AL. : FIRE SMOKE PLUMES ON BORNEO ANDthe 1997 Indonesian forest fire, Geophys. Res. Lett. , 30(

  4. FUEGO — Fire Urgency Estimator in Geosynchronous Orbit — A Proposed Early-Warning Fire Detection System

    E-Print Network [OSTI]

    Kelly, Maggi

    2013-01-01

    Kaufman, J. ; Thode, A. Fire in California’s Ecosystems;of Forest and Range Fires; National Advanced ResourceM.J. ; Zhukov, B. ; Oertel, D. Fire radiative energy for

  5. How GIS and fire indices can be used in developing a fire prediction model for Scotland 

    E-Print Network [OSTI]

    MacKinnon, Frances

    2008-12-05

    This project looks at how GIS and the six fire indices from the Canadian Forest Fire Weather Index System (FWI) could be used to aid in developing a fire prediction model for Scotland. Information on land cover type, ...

  6. FIRE /SMOKE The most effective method of fighting fires is to prevent them from occurring. All

    E-Print Network [OSTI]

    Jia, Songtao

    FIRE /SMOKE The most effective method of fighting fires is to prevent them from occurring. All-305-7979 (CUMC) after evacuating. Procedures for UNCONTROLLABLE FIRES DO NOT stay to fight a large or rapidly

  7. UC Fire Engineering Programme Structure The programme awards four qualifications: Doctor of Philosophy (PhD) in Fire

    E-Print Network [OSTI]

    Hickman, Mark

    UC Fire Engineering Programme Structure The programme awards four qualifications: Doctor of Philosophy (PhD) in Fire Engineering, Master of Engineering in Fire Engineering (MEFE), Master of Engineering Studies in Fire Engineering (MEngSt(Fire)) and a Postgraduate Certificate in Fire Engineering (PGCert(Fire

  8. How resilient are southwestern ponderosa pine forests after crown fires?

    E-Print Network [OSTI]

    Savage, M; Mast, J N

    2005-01-01

    of an intense prescribed forest fire: Is it ecologicalspecies to fires in Pinus ponderosa forests in northernIn Fire Effects in Southwestern Forests: Proceedings of the

  9. Fire Behavior Modeling - Experiment on Surface Fire Transition to the Elevated Live Fuel

    E-Print Network [OSTI]

    Omodan, Sunday

    2015-01-01

    fraction combustion model for fire simulation using CFD, TheCFD Computational Fluid Dynamics FDS Fire Dynamics Simulator FS Forest Service HoC Heat of Combustion

  10. Housing Coordinator Fire Watch Implementation Checklist A Fire Watch is an inspection conducted by DFSL staff in order to provide fire and smoke detection and emergency

    E-Print Network [OSTI]

    Hill, Wendell T.

    12 Fire Watch Housing Coordinator Fire Watch Implementation Checklist A Fire Watch is an inspection conducted by DFSL staff in order to provide fire and smoke detection and emergency warning to occupants when a building's fire alarm or sprinkler system is non-operational. Fire Watch inspectors serve as a "human smoke

  11. Fire Watch Inspector Checklist A Fire Watch is an inspection conducted by DFSL staff to provide fire and smoke detection and emergency warning

    E-Print Network [OSTI]

    Hill, Wendell T.

    14 Fire Watch Fire Watch Inspector Checklist A Fire Watch is an inspection conducted by DFSL staff to provide fire and smoke detection and emergency warning to occupants when a building's fire alarm or sprinkler system is non-operational. Fire Watch inspectors serve as a "human smoke detector" and notify 911

  12. Metal fire implications for advanced reactors. Part 1, literature review.

    SciTech Connect (OSTI)

    Nowlen, Steven Patrick; Radel, Ross F.; Hewson, John C.; Olivier, Tara Jean; Blanchat, Thomas K.

    2007-10-01

    Public safety and acceptance is extremely important for the nuclear power renaissance to get started. The Advanced Burner Reactor and other potential designs utilize liquid sodium as a primary coolant which provides distinct challenges to the nuclear power industry. Fire is a dominant contributor to total nuclear plant risk events for current generation nuclear power plants. Utilizing past experience to develop suitable safety systems and procedures will minimize the chance of sodium leaks and the associated consequences in the next generation. An advanced understanding of metal fire behavior in regards to the new designs will benefit both science and industry. This report presents an extensive literature review that captures past experiences, new advanced reactor designs, and the current state-of-knowledge related to liquid sodium combustion behavior.

  13. Evaluating fuel complexes for fire hazard mitigation planning in the southeastern United States.

    SciTech Connect (OSTI)

    Andreu, Anne G.; Shea, Dan; Parresol, Bernard, R.; Ottmar, Roger, D.

    2012-01-01

    Fire hazard mitigation planning requires an accurate accounting of fuel complexes to predict potential fire behavior and effects of treatment alternatives. In the southeastern United States, rapid vegetation growth coupled with complex land use history and forest management options requires a dynamic approach to fuel characterization. In this study we assessed potential surface fire behavior with the Fuel Characteristic Classification System (FCCS), a tool which uses inventoried fuelbed inputs to predict fire behavior. Using inventory data from 629 plots established in the upper Atlantic Coastal Plain, South Carolina, we constructed FCCS fuelbeds representing median fuel characteristics by major forest type and age class. With a dry fuel moisture scenario and 6.4 km h{sub 1} midflame wind speed, the FCCS predicted moderate to high potential fire hazard for the majority of the fuelbeds under study. To explore fire hazard under potential future fuel conditions, we developed fuelbeds representing the range of quantitative inventorydata for fuelbed components that drive surface fire behavior algorithms and adjusted shrub species composition to represent 30% and 60% relative cover of highly flammable shrub species. Results indicate that the primary drivers of surface fire behavior vary by forest type, age and surface fire behavior rating. Litter tends to be a primary or secondary driver in most forest types. In comparison to other surface fire contributors, reducing shrub loading results in reduced flame lengths most consistently across forest types. FCCS fuelbeds and the results from this project can be used for fire hazard mitigation planning throughout the southern Atlantic Coastal Plain where similar forest types occur. The approach of building simulated fuelbeds across the range of available surface fuel data produces sets of incrementally different fuel characteristics that can be applied to any dynamic forest types in which surface fuel conditions change rapidly.

  14. Energy Release Component (ERC) Fact Sheet The Energy Release Component (ERC) is a calculated output of the National Fire Danger

    E-Print Network [OSTI]

    of the National Fire Danger Rating System (NFDRS). The ERC is a number related to the available energy (BTU) per unit area (square foot) within the flaming front at the head of a fire. The ERC is consideredEnergy Release Component (ERC) Fact Sheet The Energy Release Component (ERC) is a calculated output

  15. Fire resistant PV shingle assembly

    SciTech Connect (OSTI)

    Lenox, Carl J.

    2012-10-02

    A fire resistant PV shingle assembly includes a PV assembly, including PV body, a fire shield and a connection member connecting the fire shield below the PV body, and a support and inter-engagement assembly. The support and inter-engagement assembly is mounted to the PV assembly and comprises a vertical support element, supporting the PV assembly above a support surface, an upper interlock element, positioned towards the upper PV edge, and a lower interlock element, positioned towards the lower PV edge. The upper interlock element of one PV shingle assembly is inter-engageable with the lower interlock element of an adjacent PV shingle assembly. In some embodiments the PV shingle assembly may comprise a ventilation path below the PV body. The PV body may be slidably mounted to the connection member to facilitate removal of the PV body.

  16. Fire & Evacuation Plan Page | 1 Department of Biomedical

    E-Print Network [OSTI]

    Rocke, David M.

    Fire & Evacuation Plan Page | 1 UC DAVIS Department of Biomedical Engineering FIRE & EVACUATION PLAN In compliance with: California Code of Regulations Title 8, Section 3220 Implementation Date: November 1, 2012 #12;Fire & Evacuation Plan Page | 2 UC DAVIS FIRE

  17. Fire tests and analyses of a rail cask-sized calorimeter.

    SciTech Connect (OSTI)

    Figueroa, Victor G.; Lopez, Carlos; Suo-Anttila, Ahti Jorma (Computational Engineering Analysis LLC, Albuquerque, NM); Greiner, Miles (University of Nevada, Reno, Reno, NV)

    2010-10-01

    Three large open pool fire experiments involving a calorimeter the size of a spent fuel rail cask were conducted at Sandia National Laboratories Lurance Canyon Burn Site. These experiments were performed to study the heat transfer between a very large fire and a large cask-like object. In all of the tests, the calorimeter was located at the center of a 7.93-meter diameter fuel pan, elevated 1 meter above the fuel pool. The relative pool size and positioning of the calorimeter conformed to the required positioning of a package undergoing certification fire testing. Approximately 2000 gallons of JP-8 aviation fuel were used in each test. The first two tests had relatively light winds and lasted 40 minutes, while the third had stronger winds and consumed the fuel in 25 minutes. Wind speed and direction, calorimeter temperature, fire envelop temperature, vertical gas plume speed, and radiant heat flux near the calorimeter were measured at several locations in all tests. Fuel regression rate data was also acquired. The experimental setup and certain fire characteristics that were observed during the test are described in this paper. Results from three-dimensional fire simulations performed with the Cask Analysis Fire Environment (CAFE) fire code are also presented. Comparisons of the thermal response of the calorimeter as measured in each test to the results obtained from the CAFE simulations are presented and discussed.

  18. Fire suppression and detection equipment

    SciTech Connect (OSTI)

    E.E. Bates [HSB Professional Loss Control, Lexington, KY (United States)

    2006-01-15

    Inspection and testing guidelines go beyond the 'Code of Federal Regulation'. Title 30 of the US Code of Federal Regulations (30 CFR) contains requirements and references to national standards for inspection, testing and maintenance of fire suppression and detection equipment for mine operators. However, federal requirements have not kept pace with national standards and best practices. The article lists National Fire Protection (NFPA) standards that are referenced by the US Mine Safety and Health Administration (MSHA) in 30 CFR. It then discusses other NFPA Standards excluded from 30 CFR and explains the NFPA standard development process. 2 refs., 3 tabs., 5 photos.

  19. Underground fire at Auchengeich Colliery Lanarkshire 

    E-Print Network [OSTI]

    Rogers, T. A.

    MINISTRY OF POWER UNDERGROUND FIRE AT AUCHENGEICH COLLIERY LANARKSHIRE REPORT On the causes of, and the circumstances attending, the fire which occurred at Auchengeich Colliery, Lanarkshire on 18th September, 1959 by T. ...

  20. Interactive simulation of fire, burn and decomposition 

    E-Print Network [OSTI]

    Melek, Zeki

    2009-05-15

    This work presents an approach to effectively integrate into one unified modular fire simulation framework the major processes related to fire, namely: a burning process, chemical combustion, heat distribution, decomposition and deformation...

  1. Nuclear Criticality Safety Guide for Fire Protection

    Office of Energy Efficiency and Renewable Energy (EERE)

    This guide is intended to provide information for use by fire protection professionals in the application of reasonable methods of fire protection in those facilities where there is a potential for nuclear criticality.

  2. Date ______________________ New York City Fire Department

    E-Print Network [OSTI]

    Jia, Songtao

    Date ______________________ New York City Fire Department Bureau of Fire Prevention 9 Metro-Tech Brooklyn, New York 11201 ­ 5884 Dear Sir / Madam: I am pleased to recommend Street, New York, NY 10027 212-854-8749 #12;

  3. Fire performance of gable frame structures

    E-Print Network [OSTI]

    Qian, Congyi

    2013-01-01

    Fire protection engineering and structural engineering are two relevant but separated fields of study. Many experiments conducted by fire protection engineers are under certain ideal boundary conditions, which may not be ...

  4. Interactive simulation of fire, burn and decomposition 

    E-Print Network [OSTI]

    Melek, Zeki

    2008-10-10

    This work presents an approach to effectively integrate into one unified modular fire simulation framework the major processes related to fire, namely: a burning process, chemical combustion, heat distribution, decomposition and deformation...

  5. Fire protection guide for solid waste metal drum storage

    SciTech Connect (OSTI)

    Bucci, H.M.

    1996-09-16

    This guide provides a method to assess potential fire development in drum storage facilities. The mechanism of fire propagation/spread through stored drum arrays is a complex process. It involves flame heat transfer, transient conduction,convection, and radiation between drums (stored in an array configuration). There are several phenomena which may occur when drums are exposed to fire. The most dramatic is violent lid failure which results in total lid removal. When a drum loses its lid due to fire exposure, some or all of the contents may be ejected from the drum, and both the ejected combustible material and the combustible contents remaining within the container will burn. The scope of this guide is limited to storage arrays of steel drums containing combustible (primarily Class A) and noncombustible contents. Class B combustibles may be included in small amounts as free liquid within the solid waste contents.Storage arrays, which are anticipated in this guide, include single or multi-tier palletized (steel or wood pallets) drums,high rack storage of drums, and stacked arrays of drums where plywood sheets are used between tiers. The purpose of this guide is to describe a simple methodology that estimates the consequences of a fire in drum storage arrays. The extent of fire development and the resulting heat release rates can be estimated. Release fractions applicable to this type of storage are not addressed, and the transport of contaminants away from the source is not addressed. However, such assessments require the amount of combustible material consumed and the surface area of this burning material. The methods included in this guide do provide this information.

  6. Using Satellite Fire Detection to Calibrate Components of the Fire Weather Index System in

    E-Print Network [OSTI]

    Field, Robert

    Using Satellite Fire Detection to Calibrate Components of the Fire Weather Index System in Malaysia, Indonesia ABSTRACT / Vegetation fires have become an increasing problem in tropical environments as a consequence of socioeconomic pressures and subsequent land-use change. In response, fire management systems

  7. Assessing fire risk using Monte Carlo simulations of fire spread Yohay Carmel a,

    E-Print Network [OSTI]

    Assessing fire risk using Monte Carlo simulations of fire spread Yohay Carmel a, *, Shlomit Paz b of Haifa, Haifa, Israel 1. Introduction Fires are a major source of forest destruction in the Mediterranean., 2000). Mediterranean fires are largely determined by climatic conditions; long, dry summers with high

  8. Limitations imposed on fire PRA methods as the result of incomplete and uncertain fire event data.

    SciTech Connect (OSTI)

    Nowlen, Steven Patrick; Hyslop, J. S. (U.S. Nuclear Regulatory Commission, Washington, DC)

    2010-04-01

    Fire probabilistic risk assessment (PRA) methods utilize data and insights gained from actual fire events in a variety of ways. For example, fire occurrence frequencies, manual fire fighting effectiveness and timing, and the distribution of fire events by fire source and plant location are all based directly on the historical experience base. Other factors are either derived indirectly or supported qualitatively based on insights from the event data. These factors include the general nature and intensity of plant fires, insights into operator performance, and insights into fire growth and damage behaviors. This paper will discuss the potential methodology improvements that could be realized if more complete fire event reporting information were available. Areas that could benefit from more complete event reporting that will be discussed in the paper include fire event frequency analysis, analysis of fire detection and suppression system performance including incipient detection systems, analysis of manual fire fighting performance, treatment of fire growth from incipient stages to fully-involved fires, operator response to fire events, the impact of smoke on plant operations and equipment, and the impact of fire-induced cable failures on plant electrical circuits.

  9. Longleaf pine (Pinus palustris Mill.) fire scars reveal new details of a frequent fire regime

    E-Print Network [OSTI]

    Stambaugh, Michael C

    Longleaf pine (Pinus palustris Mill.) fire scars reveal new details of a frequent fire regime, University of Missouri ­ Columbia, MO 65211, USA Abstract Question: How frequent and variable were fire disturbances in longleaf pine ecosystems? Has the frequency and seasonality of fire events changed during

  10. Nacogdoches Fire DepartmentNacogdoches Fire Department Service Call Density andService Call Density and

    E-Print Network [OSTI]

    Hung, I-Kuai

    in areas of fire, rescue, medical emergencies,of fire, rescue, medical emergencies, hazardous materials ·· Medical AssistanceMedical Assistance ·· Hazardous Materials IncidentsHazardous Materials IncidentsBuilding of New Stations ­­ Locating Areas Fire Education Can BenefitLocating Areas Fire Education Can Benefit

  11. CQ2. Fire and Vegetation Composition How are fires and vegetation composition coupled?

    E-Print Network [OSTI]

    Christian, Eric

    in conjunction with information on ecosystem health acquired from HyspIRI VSWIR data. Fire temperature retrieved: How does the timing, temperature and frequency of fires affect long-term ecosystem health? ! Science issue The state of an ecosystem can be affected by changes in fire regime. Changes in both fire

  12. Fire Effects on Forest Soil: Cave Gulch Fire, Helena National Forest TABLE OF CONTENTS

    E-Print Network [OSTI]

    Maxwell, Bruce D.

    Fire Effects on Forest Soil: Cave Gulch Fire, Helena National Forest #12;ii TABLE OF CONTENTS ecosystems. Historically, ponderosa pine (Pinus contorta) forest systems have had low intensity fires every forests. Once forest managers began suppressing forest fires, vegetation and debris accumulated

  13. Growth and reproduction of Scirpus americanus following fire and lesser snow geese herbivory on the upper Texas Gulf coast 

    E-Print Network [OSTI]

    Stahman, Matthew Glen

    1996-01-01

    and Louisiana Gulf coasts. Fire is used in the management of S-. ameficanus stands. This study was designed to evaluate the influence of fire and LSG herbivory on growth, development, and reproduction of SciEpus americanus. The study was conducted along...

  14. Fire Protection for Underground Research Facilities

    Broader source: Energy.gov [DOE]

    Presenter: James Priest, Ph.D., Senior Fire Protection Engineer ES&H, Universities Research Associates ? FNAL

  15. Fire Modeling Examples in a Nuclear World

    Broader source: Energy.gov [DOE]

    Presenter: Mark Schairer, P.E.,Technical Manager, Fire Protection Engineering Division - Engineering Planning and Management (EPM), Inc.

  16. DEVELOPMENT OF FINE PARTICULATE EMISSION FACTORS AND SPECIATION PROFILES FOR OIL AND GAS-FIRED COMBUSTION SYSTEMS

    SciTech Connect (OSTI)

    Glenn C. England; Stephanie Wien; Mingchih O. Chang

    2002-08-01

    This report provides results from the first year of this three-year project to develop dilution measurement technology for characterizing PM2.5 (particles with aerodynamic diameter smaller than 2.5 micrometers) and precursor emissions from stationary combustion sources used in oil, gas and power generation operations. Detailed emission rate and chemical speciation test results for a refinery gas-fired process heater and plans for cogeneration gas turbine tests and pilot-scale tests are presented. Tests were performed using a research dilution sampling apparatus and traditional EPA methods to compare PM2.5 mass and chemical speciation. Test plans are presented for a gas turbine facility that will be tested in the fourth quarter of 2002. A preliminary approach for pilot-scale tests is presented that will help define design constraints for a new dilution sampler design that is smaller, lighter, and less costly to use.

  17. ORIGINAL PAPER Coupled fireatmosphere modeling of wildland fire

    E-Print Network [OSTI]

    Xue, Ming

    ORIGINAL PAPER Coupled fire­atmosphere modeling of wildland fire spread using DEVS-FIRE and ARPS US Government 2015 Abstract This article introduces a new wildland fire spread prediction system consisting of the raster-based Discrete Event System Specification Fire model (DEVS-FIRE) and the Advanced

  18. STATISTICAL METHODS FOR1 ESTIMATING HISTORICAL FIRE2

    E-Print Network [OSTI]

    Reed, W.J.

    STATISTICAL METHODS FOR1 ESTIMATING HISTORICAL FIRE2 FREQUENCY FROM MULTIPLE FIRE3 SCAR DATA.4 of fire-interval charts8 based on fire-scar data. Estimation of the fire interval (expected time9 between scar-registering fires at any location) by maximum likelihood10 is presented. Because of the fact

  19. ANNUAL FIRE SAFETY REPORT October 1, 2014

    E-Print Network [OSTI]

    Emmons, Scott

    ® ANNUAL FIRE SAFETY REPORT October 1, 2014 ALBERT EINSTEIN COLLEGE OF MEDICINE JACK AND PEARL RESNICK CAMPUS BRONX, NY #12;2 October, 2014 POLICY: FIRE SAFETY REPORTING AND DISCLOSURES Introduction), the University has established the following reporting and disclosure procedures with respect to fire safety

  20. Fire Safety Report For CY 2013

    E-Print Network [OSTI]

    Alexandrova, Ivana

    Annual Security & Fire Safety Report For CY 2013 Higher Education Opportunity Act (Clery Act) #12;ANNUAL SECURITY & FIRE SAFETY REPORT UNDER THE CLERY ACT Page 2 of 125 AS&FSR, September 2014 http;ANNUAL SECURITY & FIRE SAFETY REPORT UNDER THE CLERY ACT Page 3 of 125 AS&FSR, September 2014 http

  1. 4, 27472779, 2004 Boreal forest fires

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    ACPD 4, 2747­2779, 2004 Boreal forest fires 1997/1998 N. Spichtinger et al. Title Page Abstract Discussions Boreal forest fires in 1997 and 1998: a seasonal comparison using transport model simulations, 2747­2779, 2004 Boreal forest fires 1997/1998 N. Spichtinger et al. Title Page Abstract Introduction

  2. Spatiotemporal Dynamics of Insect-Fire Interactions

    E-Print Network [OSTI]

    Moorcroft, Paul R.

    and forest fires individually represent significant forest disturbances which have long-term effects on the dynamics and composition of forest ecosystems. Although it has long been speculated that forest fires of data on western spruce budworm out- breaks and forest fires in British Columbia using a spatiotemporal

  3. 7, 49254979, 2007 Forest fire plumes in

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    ACPD 7, 4925­4979, 2007 Forest fire plumes in the European free troposphere A. Petzold et al. Title forest fire plumes during the ICARTT-ITOP Experiment in summer 2004 A. Petzold1 , B. Weinzierl1 , H Correspondence to: A. Petzold (andreas.petzold@dlr.de) 4925 #12;ACPD 7, 4925­4979, 2007 Forest fire plumes

  4. 6, 32273264, 2006 Forest fire smoke

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    ACPD 6, 3227­3264, 2006 Forest fire smoke plume V. R. Kotamarthi et al. Title Page Abstract Discussions Modeling of trace gases from the 1998 North Central Mexico forest fire smoke plume, as measured Forest fire smoke plume V. R. Kotamarthi et al. Title Page Abstract Introduction Conclusions References

  5. Wildland Fire Protection Program NEBRASKA FOREST SERVICE

    E-Print Network [OSTI]

    Farritor, Shane

    Wildland Fire Protection Program NEBRASKA FOREST SERVICE HOW NEBRASKANS BENEFIT: · improved districts · increased firefighter knowledge of wildland fire suppression and prevention · reduced forest.nfs.unl.edu Dr. Scott Josiah State Forester & Director (402) 472-1467 sjosiah2@unl.edu Don Westover Wildland Fire

  6. FIRE AND CLIMATE CHANGE IN CALIFORNIA

    E-Print Network [OSTI]

    FIRE AND CLIMATE CHANGE IN CALIFORNIA Changes in the Distribution and Frequency of Fire's California Climate Change Center JULY 2012 CEC5002012026 Prepared for: California Energy Commission to climate change has the potential to induce alteration of future fire activity. This research presents just

  7. Global fire emissions and the contribution of deforestation, savanna, forest, agricultural, and peat fires (1997-2009)

    E-Print Network [OSTI]

    2010-01-01

    at total deforestation car- bon emissions is prone to largesavanna on fires car- were bon emissions. Savanna fires

  8. Hydrocarbon characterization experiments in fully turbulent fires : results and data analysis.

    SciTech Connect (OSTI)

    Suo-Anttila, Jill Marie; Blanchat, Thomas K.

    2011-03-01

    As the capabilities of numerical simulations increase, decision makers are increasingly relying upon simulations rather than experiments to assess risks across a wide variety of accident scenarios including fires. There are still, however, many aspects of fires that are either not well understood or are difficult to treat from first principles due to the computational expense. For a simulation to be truly predictive and to provide decision makers with information which can be reliably used for risk assessment the remaining physical processes must be studied and suitable models developed for the effects of the physics. The model for the fuel evaporation rate in a liquid fuel pool fire is significant because in well-ventilated fires the evaporation rate largely controls the total heat release rate from the fire. This report describes a set of fuel regression rates experiments to provide data for the development and validation of models. The experiments were performed with fires in the fully turbulent scale range (> 1 m diameter) and with a number of hydrocarbon fuels ranging from lightly sooting to heavily sooting. The importance of spectral absorption in the liquid fuels and the vapor dome above the pool was investigated and the total heat flux to the pool surface was measured. The importance of convection within the liquid fuel was assessed by restricting large scale liquid motion in some tests. These data sets provide a sound, experimentally proven basis for assessing how much of the liquid fuel needs to be modeled to enable a predictive simulation of a fuel fire given the couplings between evaporation of fuel from the pool and the heat release from the fire which drives the evaporation.

  9. Algorithm FIRE -- Feynman Integral REduction

    E-Print Network [OSTI]

    A. V. Smirnov

    2008-08-02

    The recently developed algorithm FIRE performs the reduction of Feynman integrals to master integrals. It is based on a number of strategies, such as applying the Laporta algorithm, the s-bases algorithm, region-bases and integrating explicitly over loop momenta when possible. Currently it is being used in complicated three-loop calculations.

  10. Summary report, California Department of Forestry and Fire Protection evaluation of full-face air-purifying respirators for wildland fire fighting use

    SciTech Connect (OSTI)

    Beason, D.G.; Johnson, J.S.; Foote, K.L. [Lawrence Livermore National Lab., CA (United States); Weaver, W.A. [California Dept. of Forestry and Fire Protection, Sacramento, CA (United States)

    1996-02-01

    Wildland fire suppression personnel employed by the CDF do not currently have the equipment to protect themselves from the short-term acute affects of smoke from wildland fires. In addition, no regulations exist that specify appropriate respiratory protection and the current air-purifying respirator technology and carbon monoxide monitoring has not been adapted to fit wildland fire suppression requirements. This three-year limited study evaluated the ability of wildland fire fighters to perform their normal job function while wearing full-face air-purifying respirators. In the first two years of this study we designed, developed and field tested a prototype ``smart`` air-purifying respirator which incorporated a real-time carbon monoxide monitor into a commercial full-face respirator.` Data on carbon monoxide exposure while fighting wildland fires was collected. During the third year of this study we evaluated eight different commercially available full-face air-purifying respirators equipped with a variety of cartridges. Apparatus to aid the fire fighter in carrying the respirator and carbon monoxide personal monitor was designed and fabricated. A smoke exposure test method was developed and a laboratory study on the penetration of smoke through respirator cartridges was conducted.

  11. Stirling engines for gas fired micro-cogen and cooling

    SciTech Connect (OSTI)

    Lane, N.W.; Beale, W.T.

    1996-12-31

    This paper describes the design and performance of free-piston Stirling engine-alternators particularly suited for use as natural gas fired micro-cogen and cooling devices. Stirling based cogen systems offer significant potential advantages over internal combustion engines in efficiency, to maintain higher efficiencies at lower power levels than than combustion engines significantly expands the potential for micro-cogen. System cost reduction and electric prices higher than the U.S. national average will have a far greater effect on commercial success than any further increase in Stirling engine efficiency. There exist niche markets where Stirling engine efficiency. There exist niche markets where Stirling based cogen systems are competitive. Machines of this design are being considered for production in the near future as gas-fired units for combined heat and power in sufficiently large quantities to assure competitive prices for the final unit.

  12. Aging assessment for active fire protection systems

    SciTech Connect (OSTI)

    Ross, S.B. [Science and Engineering Associates, Inc. (United States); Nowlen, S.P.; Tanaka, T. [Sandia National Labs., Albuquerque, NM (United States)

    1995-06-01

    This study assessed the impact of aging on the performance and reliability of active fire protection systems including both fixed fire suppression and fixed fire detection systems. The experience base shows that most nuclear power plants have an aggressive maintenance and testing program and are finding degraded fire protection system components before a failure occurs. Also, from the data reviewed it is clear that the risk impact of fire protection system aging is low. However, it is assumed that a more aggressive maintenance and testing program involving preventive diagnostics may reduce the risk impact even further.

  13. Fire aerosol experiment and comparisons with computer code predictions

    SciTech Connect (OSTI)

    Gregory, W.S.; Nichols, B.D.; White, B.W.; Smith, P.R.; Leslie, I.H.; Corkran, J.R.

    1988-01-01

    Los Alamos National Laboratory, in cooperation with New Mexico State University, has carried on a series of tests to provide experimental data on fire-generated aerosol transport. These data will be used to verify the aerosol transport capabilities of the FIRAC computer code. FIRAC was developed by Los Alamos for the US Nuclear Regulatory Commission. It is intended to be used by safety analysts to evaluate the effects of hypothetical fires on nuclear plants. One of the most significant aspects of this analysis deals with smoke and radioactive material movement throughout the plant. The tests have been carried out using an industrial furnace that can generate gas temperatures to 300/degree/C. To date, we have used quartz aerosol with a median diameter of about 10 ..mu..m as the fire aerosol simulant. We also plan to use fire-generated aerosols of polystyrene and polymethyl methacrylate (PMMA). The test variables include two nominal gas flow rates (150 and 300 ft/sup 3//min) and three nominal gas temperatures (ambient, 150/degree/C, and 300/degree/C). The test results are presented in the form of plots of aerosol deposition vs length of duct. In addition, the mass of aerosol caught in a high-efficiency particulate air (HEPA) filter during the tests is reported. The tests are simulated with the FIRAC code, and the results are compared with the experimental data. 3 refs., 10 figs., 1 tab.

  14. Controlling mercury emissions from coal-fired power plants

    SciTech Connect (OSTI)

    Chang, R. [Electric Power Research Institute, Palo Alto, CA (United States)

    2009-07-15

    Increasingly stringent US federal and state limits on mercury emissions form coal-fired power plants demand optimal mercury control technologies. This article summarises the successful removal of mercury emissions achieved with activated carbon injection and boiler bromide addition, technologies nearing commercial readiness, as well as several novel control concepts currently under development. It also discusses some of the issues standing in the way of confident performance and cost predictions. In testing conducted on western coal-fired units with fabric filters or TOXECON to date, ACI has generally achieved mercury removal rates > 90%. At units with ESPs, similar performance requires brominated ACI. Alternatively, units firing western coals can use boiler bromide addition to increase flue gas mercury oxidation and downstream capture in a wet scrubber, or to enhance mercury removal by ACI. At eastern bituminous fired units with ESPs, ACI is not as effective, largely due to SO{sub 3} resulting from the high sulfur content of the coal or the use of SO{sub 3} flue gas conditioning to improve ESP performance. 7 refs., 3 figs.

  15. Pigments which reflect infrared radiation from fire

    DOE Patents [OSTI]

    Berdahl, Paul H. (Oakland, CA)

    1998-01-01

    Conventional paints transmit or absorb most of the intense infrared (IR) radiation emitted by fire, causing them to contribute to the spread of fire. The present invention comprises a fire retardant paint additive that reflects the thermal IR radiation emitted by fire in the 1 to 20 micrometer (.mu.m) wavelength range. The important spectral ranges for fire control are typically about 1 to about 8 .mu.m or, for cool smoky fires, about 2 .mu.m to about 16 .mu.m. The improved inventive coatings reflect adverse electromagnetic energy and slow the spread of fire. Specific IR reflective pigments include titanium dioxide (rutile) and red iron oxide pigments with diameters of about 1 .mu.m to about 2 .mu.m and thin leafing aluminum flake pigments.

  16. Pigments which reflect infrared radiation from fire

    DOE Patents [OSTI]

    Berdahl, P.H.

    1998-09-22

    Conventional paints transmit or absorb most of the intense infrared (IR) radiation emitted by fire, causing them to contribute to the spread of fire. The present invention comprises a fire retardant paint additive that reflects the thermal IR radiation emitted by fire in the 1 to 20 micrometer ({micro}m) wavelength range. The important spectral ranges for fire control are typically about 1 to about 8 {micro}m or, for cool smoky fires, about 2 {micro}m to about 16 {micro}m. The improved inventive coatings reflect adverse electromagnetic energy and slow the spread of fire. Specific IR reflective pigments include titanium dioxide (rutile) and red iron oxide pigments with diameters of about 1 {micro}m to about 2 {micro}m and thin leafing aluminum flake pigments. 4 figs.

  17. ELECTRICITY FROM WOOD-FIRED GASIFICATION IN UGANDA -A 250 AND 10KW CASE STUDY

    E-Print Network [OSTI]

    Vermont, University of

    electricity at US$ 0.18 and 0.34/kWh, respectively. A stable electricity demand close to the rated capacityELECTRICITY FROM WOOD-FIRED GASIFICATION IN UGANDA - A 250 AND 10KW CASE STUDY Thomas Buchholza their potential to compete economically with diesel generated electricity when operating close to the rated

  18. Residential oil burners with low input and two stages firing

    SciTech Connect (OSTI)

    Butcher, T.; Krajewski, R.; Leigh, R.

    1997-12-31

    The residential oil burner market is currently dominated by the pressure-atomized, retention head burner. At low firing rates pressure atomizing nozzles suffer rapid fouling of the small internal passages, leading to bad spray patterns and poor combustion performance. To overcome the low input limitations of conventional burners, a low pressure air-atomized burner has been developed watch can operate at fining rates as low as 0.25 gallons of oil per hour (10 kW). In addition, the burner can be operated in a high/low fining rate mode. Field tests with this burner have been conducted at a fixed input rate of 0.35 gph (14 kW) with a side-wall vented boiler/water storage tank combination. At the test home, instrumentation was installed to measure fuel and energy flows and record trends in system temperatures. Laboratory efficiency testing with water heaters and boilers has been completed using standard single purpose and combined appliance test procedures. The tests quantify benefits due to low firing rates and other burner features. A two stage oil burner gains a strong advantage in rated efficiency while maintaining capacity for high domestic hot water and space heating loads.

  19. New 90,000 PPH Coal Fired Boiler Plant at Liggett & Myers Tobacco Company, Durham North Carolina 

    E-Print Network [OSTI]

    Kaskey, G. T.

    1984-01-01

    Liggett & Myers Tobacco Company in Durham, North Carolina is installing a future cogeneration, coal fired boiler system designed and built by Energy Systems (ESI) of Chattanooga, Tennessee. The complete boiler plant is comprised of a 90,000 pph Dorr...

  20. Fire hazard analysis for the fuel supply shutdown storage buildings

    SciTech Connect (OSTI)

    REMAIZE, J.A.

    2000-09-27

    The purpose of a fire hazards analysis (FHA) is to comprehensively assess the risk from fire and other perils within individual fire areas in a DOE facility in relation to proposed fire protection so as to ascertain whether the objectives of DOE 5480.7A, Fire Protection, are met. This Fire Hazards Analysis was prepared as required by HNF-PRO-350, Fire Hazards Analysis Requirements, (Reference 7) for a portion of the 300 Area N Reactor Fuel Fabrication and Storage Facility.

  1. GAS SURFACE DENSITY, STAR FORMATION RATE SURFACE DENSITY, AND THE MAXIMUM MASS OF YOUNG STAR CLUSTERS IN A DISK GALAXY. II. THE GRAND-DESIGN GALAXY M51

    SciTech Connect (OSTI)

    Gonzalez-Lopezlira, Rosa A. [On sabbatical leave from the Centro de Radioastronomia y Astrofisica, UNAM, Campus Morelia, Michoacan, C.P. 58089, Mexico. (Mexico); Pflamm-Altenburg, Jan; Kroupa, Pavel, E-mail: r.gonzalez@crya.unam.mx [Argelander Institut fuer Astronomie, Universitaet Bonn, Auf dem Huegel 71, D-53121 Bonn (Germany)

    2013-06-20

    We analyze the relationship between maximum cluster mass and surface densities of total gas ({Sigma}{sub gas}), molecular gas ({Sigma}{sub H{sub 2}}), neutral gas ({Sigma}{sub H{sub I}}), and star formation rate ({Sigma}{sub SFR}) in the grand-design galaxy M51, using published gas data and a catalog of masses, ages, and reddenings of more than 1800 star clusters in its disk, of which 223 are above the cluster mass distribution function completeness limit. By comparing the two-dimensional distribution of cluster masses and gas surface densities, we find for clusters older than 25 Myr that M{sub 3rd}{proportional_to}{Sigma}{sub H{sub I}{sup 0.4{+-}0.2}}, whereM{sub 3rd} is the median of the five most massive clusters. There is no correlation with{Sigma}{sub gas},{Sigma}{sub H2}, or{Sigma}{sub SFR}. For clusters younger than 10 Myr, M{sub 3rd}{proportional_to}{Sigma}{sub H{sub I}{sup 0.6{+-}0.1}} and M{sub 3rd}{proportional_to}{Sigma}{sub gas}{sup 0.5{+-}0.2}; there is no correlation with either {Sigma}{sub H{sub 2}} or{Sigma}{sub SFR}. The results could hardly be more different from those found for clusters younger than 25 Myr in M33. For the flocculent galaxy M33, there is no correlation between maximum cluster mass and neutral gas, but we have determined M{sub 3rd}{proportional_to}{Sigma}{sub gas}{sup 3.8{+-}0.3}, M{sub 3rd}{proportional_to}{Sigma}{sub H{sub 2}{sup 1.2{+-}0.1}}, and M{sub 3rd}{proportional_to}{Sigma}{sub SFR}{sup 0.9{+-}0.1}. For the older sample in M51, the lack of tight correlations is probably due to the combination of strong azimuthal variations in the surface densities of gas and star formation rate, and the cluster ages. These two facts mean that neither the azimuthal average of the surface densities at a given radius nor the surface densities at the present-day location of a stellar cluster represent the true surface densities at the place and time of cluster formation. In the case of the younger sample, even if the clusters have not yet traveled too far from their birth sites, the poor resolution of the radio data compared to the physical sizes of the clusters results in measured{Sigma} that are likely quite diluted compared to the actual densities relevant for the formation of the clusters.

  2. Chaotic Dynamics of Forest Fires

    E-Print Network [OSTI]

    K. Malarz; S. Kaczanowska; K. Kulakowski

    2002-04-25

    In the thermodynamic limit, a probabilistic cellular automaton can be approximated by a deterministic nonlinear map. Here we construct such a map for the forest fire problem. The construction is based on the results of the Monte Carlo simulation, performed on a square lattice of million cells. The results of the calculation are analyzed by means of the Hoshen--Kopelman algorithm (HKA). The only parameter of the map describes the probability that a tree appears at an empty cell during one time step. The obtained map seems to be non-differentiable at the percolation threshold. The Lyapunov exponent for the map is positive. Also, we found the cycle of length three by means of the method of symbolic dynamics. The results are illustrated by the experimental data on the forest fires in Canada in years 1970--2000. Although these data are fortunately far from thermodynamic limit, their qualitative character is reproduced for smaller lattices.

  3. Fire Ants and Their Control. 

    E-Print Network [OSTI]

    Hamman, Philip J.; Drees, Bastiaan M.; Vinson, S. Bradleigh

    1986-01-01

    Agricultural Extension Service because these substances are dangerously flammable, kill grass and plants around the treated mounds and can seriously pollute the soil. Other home remedies include soap solutions, cleaning products or wood ashes soaked... ant workers feed on parts of plants or remove planted corn, peanut or soybean seeds and/or seedlings. Seed treat ments or insecticides applied before or at planting to control soil insects usually will prevent fire ant damage, although...

  4. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    E-Print Network [OSTI]

    Darghouth, Naim Richard

    2013-01-01

    payments in imperfect electricity markets: Need and design.Economics of Renewable Electricity Market Integration. Angeneration in the Irish electricity market, in: 30th IAEE/

  5. Uncertainties in the Value of Bill Savings from Behind-the-Meter, Residential Photovoltaic Systems: The Roles of Electricity Market Conditions, Retail Rate Design, and Net Metering

    E-Print Network [OSTI]

    Darghouth, Naim Richard

    2013-01-01

    2008. Capacity payments in imperfect electricity markets:capacity adequacy in the competitive electricity marketelectricity market design with price caps and a separate capacity market,

  6. Fire and materials modeling for transportation systems

    SciTech Connect (OSTI)

    Skocypec, R.D.; Gritzo, L.A.; Moya, J.L.; Nicolette, V.F.; Tieszen, S.R.; Thomas, R.

    1994-10-01

    Fire is an important threat to the safety of transportation systems. Therefore, understanding the effects of fire (and its interaction with materials) on transportation systems is crucial to quantifying and mitigating the impact of fire on the safety of those systems. Research and development directed toward improving the fire safety of transportation systems must address a broad range of phenomena and technologies, including: crash dynamics, fuel dispersion, fire environment characterization, material characterization, and system/cargo thermal response modeling. In addition, if the goal of the work is an assessment and/or reduction of risk due to fires, probabilistic risk assessment technology is also required. The research currently underway at Sandia National Laboratories in each of these areas is summarized in this paper.

  7. Commercialization Development of Oxygen Fired CFB for Greenhouse Gas Control

    SciTech Connect (OSTI)

    Nsakala ya Nsakala; Gregory N. Liljedahl; David G. Turek

    2007-03-31

    Given that fossil fuel fired power plants are among the largest and most concentrated producers of CO{sub 2} emissions, recovery and sequestration of CO{sub 2} from the flue gas of such plants has been identified as one of the primary means for reducing anthropogenic (i.e., man-made) CO{sub 2} emissions. In 2001, ALSTOM Power Inc. (ALSTOM) began a two-phase program to investigate the feasibility of various carbon capture technologies. This program was sponsored under a Cooperative Agreement from the US Department of Energy's National Energy Technology Laboratory (DOE). The first phase entailed a comprehensive study evaluating the technical feasibility and economics of alternate CO{sub 2} capture technologies applied to Greenfield US coal-fired electric generation power plants. Thirteen cases, representing various levels of technology development, were evaluated. Seven cases represented coal combustion in CFB type equipment. Four cases represented Integrated Gasification Combined Cycle (IGCC) systems. Two cases represented advanced Chemical Looping Combined Cycle systems. Marion, et al. reported the details of this work in 2003. One of the thirteen cases studied utilized an oxygen-fired circulating fluidized bed (CFB) boiler. In this concept, the fuel is fired with a mixture of oxygen and recirculated flue gas (mainly CO{sub 2}). This combustion process yields a flue gas containing over 80 percent (by volume) CO{sub 2}. This flue gas can be processed relatively easily to enrich the CO{sub 2} content to over 96 percent for use in enhanced oil or gas recovery (EOR or EGR) or simply dried for sequestration. The Phase I study identified the O{sub 2}-fired CFB as having a near term development potential, because it uses conventional commercial CFB technology and commercially available CO{sub 2} capture enabling technologies such as cryogenic air separation and simple rectification or distillation gas processing systems. In the long term, air separation technology advancements offer significant reductions in power requirements, which would improve plant efficiency and economics for the oxygen-fired technology. The second phase consisted of pilot-scale testing followed by a refined performance and economic evaluation of the O{sub 2} fired CFB concept. As a part of this workscope, ALSTOM modified its 3 MW{sub th} (9.9 MMBtu/hr) Multiuse Test Facility (MTF) pilot plant to operate with O{sub 2}/CO{sub 2} mixtures of up to 70 percent O{sub 2} by volume. Tests were conducted with coal and petroleum coke. The test objectives were to determine the impacts of oxygen firing on heat transfer, bed dynamics, potential agglomeration, and gaseous and particulate emissions. The test data results were used to refine the design, performance, costs, and economic models developed in Phase-I for the O{sub 2}-fired CFB with CO{sub 2} capture. Nsakala, Liljedahl, and Turek reported results from this study in 2004. ALSTOM identified several items needing further investigation in preparation for large scale demonstration of the oxygen-fired CFB concept, namely: (1) Operation and performance of the moving bed heat exchanger (MBHE) to avoid recarbonation and also for cost savings compared to the standard bubbling fluid bed heat exchanger (FBHE); (2) Performance of the back-end flash dryer absorber (FDA) for sulfur capture under high CO{sub 2}/high moisture flue gas environment using calcined limestone in the fly ash and using fresh commercial lime directly in the FDA; (3) Determination of the effect of recarbonation on fouling in the convective pass; (4) Assessment of the impact of oxygen firing on the mercury, other trace elements, and volatile organic compound (VOC) emissions; and (5) Develop a proposal-level oxygen-fired retrofit design for a relatively small existing CFB steam power plant in preparation for a large-scale demonstration of the O{sub 2} fired CFB concept. Hence, ALSTOM responded to a DOE Solicitation to address all these issues with further O{sub 2} fired MTF pilot testing and a subsequent retrofit design study of oxygen firing and CO{s

  8. Preventing the self-destruction of the indirect coal firing system

    SciTech Connect (OSTI)

    Bush, C.W.; Rayner, C.C.

    1983-07-01

    The most widely used fuel in the cement industry is pulverized coal. The current trend is to burn coal through the use of an indirect firing system, as opposed to direct firing which was formerly standard for cement kilns. Indirect firing is favored for precalciners and to improve thermal efficiency, but the benefits are sometimes overshadowed by increased hazard potential. Thoughtful design and careful operating practices are essential for safe operation. The hazards are primarily a result of the explosive mixture of coal and air which can be formed in various parts of the system and the tendency for coal to self-heat and undergo spontaneous combustion. The systems for indirect coal firing are reviewed, with emphasis on the potential fire and explosion hazards. The effectiveness of various methods to extinguish a fire or suppress an explosion is discussed, together with their applicability and related operating problems. The available alarm systems are evaluated according to their ability to signal impending danger in time for corrective action. Some parameters of safe design and operating practices are outlined as a guide to avoiding the types of problems that have been experienced at some existing installations.

  9. BRE large compartment fire tests – characterising post-flashover fires for model validation 

    E-Print Network [OSTI]

    Welch, Stephen; Jowsey, Allan; Deeny, Susan; Morgan, Richard; Torero, Jose L

    2007-01-01

    Reliable and comprehensive measurement data from large-scale fire tests is needed for validation of computer fire models, but is subject to various uncertainties, including radiation errors in temperature measurement. Here, ...

  10. Alternative approach for fire suppression of class A, B and C fires in gloveboxes

    SciTech Connect (OSTI)

    Rosenberger, Mark S; Tsiagkouris, James A

    2011-02-10

    Department of Energy (DOE) Orders and National Fire Protection Association (NFPA) Codes and Standards require fire suppression in gloveboxes. Several potential solutions have been and are currently being considered at Los Alamos National Laboratory (LANL). The objective is to provide reliable, minimally invasive, and seismically robust fire suppression capable of extinguishing Class A, B, and C fires; achieve compliance with DOE and NFPA requirements; and provide value-added improvements to fire safety in gloveboxes. This report provides a brief summary of current approaches and also documents the successful fire tests conducted to prove that one approach, specifically Fire Foe{trademark} tubes, is capable of achieving the requirement to provide reliable fire protection in gloveboxes in a cost-effective manner.

  11. Fire Behavior Modeling - Experiment on Surface Fire Transition to the Elevated Live Fuel

    E-Print Network [OSTI]

    Omodan, Sunday

    2015-01-01

    of FDS to recognize two fuels of different materials in theFire Behavior Prediction and Fuel Modeling System, BURN -K.P. Combustion of forest fuels in Forest Fire: Control and

  12. Fire dynamics and carbon cycling of miombo woodlands

    E-Print Network [OSTI]

    Fire dynamics and carbon cycling of miombo woodlands Supervised by Mat Williams & Casey Ryan #12 extraction · Fire #12;#12;Research Questions 1. How does fire activity relate to forest biomass? 2. Can fire be linked to tree mortality? 3. Can modelling techniques be used to understand the impact of fire in SE

  13. Fire Hazard Analysis for the Cold Vacuum Drying (CVD) Facility

    SciTech Connect (OSTI)

    JOHNSON, B.H.

    1999-08-19

    This Fire Hazard Analysis assesses the risk from fire within individual fire areas in the Cold Vacuum Drying Facility at the Hanford Site in relation to existing or proposed fire protection features to ascertain whether the objectives of DOE Order 5480.7A Fire Protection are met.

  14. forest ecology Using Fire to Increase the Scale, Benefits, and

    E-Print Network [OSTI]

    North, Malcolm

    forest ecology Using Fire to Increase the Scale, Benefits, and Future Maintenance of Fuels limited to affect fire severity and the Forest Service has predominantly focused on suppression, and institutional barriers to increased fire use that we discuss. Keywords: fire policy, fire suppression, forest

  15. Spent Fuel Transportation Package Response to the Baltimore Tunnel Fire Scenario

    SciTech Connect (OSTI)

    Adkins, Harold E.; Cuta, Judith M.; Koeppel, Brian J.; Guzman, Anthony D.; Bajwa, Christopher S.

    2006-11-15

    On July 18, 2001, a freight train carrying hazardous (non-nuclear) materials derailed and caught fire while passing through the Howard Street railroad tunnel in downtown Baltimore, Maryland. The United States Nuclear Regulatory Commission (USNRC), one of the agencies responsible for ensuring the safe transportation of radioactive materials in the United States, undertook an investigation of the train derailment and fire to determine the possible regulatory implications of this particular event for the transportation of spent nuclear fuel by railroad. Shortly after the accident occurred, the USNRC met with the National Transportation Safety Board (NTSB, the U.S. agency responsible for determining the cause of transportation accidents), to discuss the details of the accident and the ensuing fire. Following these discussions, the USNRC assembled a team of experts from the National Institute of Standards and Technology (NIST), the Center for Nuclear Waste Regulatory Analyses (CNWRA), and Pacific Northwest National Laboratory (PNNL) to determine the thermal conditions that existed in the Howard Street tunnel fire and analyze the effects of this fire on various spent fuel transportation package designs. The Fire Dynamics Simulator (FDS) code, developed by NIST, was used to determine the thermal environment present in the Howard Street tunnel during the fire. The FDS results were used as boundary conditions in the COBRA-SFS and ANSYS® computer codes to evaluate the thermal performance of different package designs. The staff concluded that larger transportation packages resembling the HOLTEC Model No. HI STAR 100 and TransNuclear Model No. TN-68 would withstand a fire with thermal conditions similar to those that existed in the Baltimore tunnel fire event with only minor damage to peripheral components. This is due to their sizable thermal inertia and design specifications in compliance with currently imposed regulatory requirements. The staff also concluded that some components of smaller transportation packages resembling the NAC Model No. LWT, despite placement within an ISO container, could degrade. USNRC staff evaluated the radiological consequences of the package responses to the Baltimore tunnel fire. Though components in some packages heated up beyond their service temperatures, the staff determined that there would be no significant dose as a result of the fire for any of these and similar packages.

  16. Planning Rural Fire Protection for Texas. 

    E-Print Network [OSTI]

    Jones, Jack L.

    1981-01-01

    include cost of fire fighting equipment, housing and annual operating expense. (See Section on Estimating Cost and Benefits.) Along with cost of a workable method of financing, the program should be outlined. During the planning stage, individuals... where no insurance credit is given for an unapproved water system or fire department, a fire insurance credit of 10 percent can be allowed for one automobile separate booster tank truck. This truck has a tank of not less than 350 gallons capacity, nor...

  17. Lead exposure at uncovered outdoor firing ranges

    SciTech Connect (OSTI)

    Goldberg, R.L.; Hicks, A.M.; O'Leary, L.M.; London, S. (University of Southern California School of Medicine, Los Angeles (USA))

    1991-06-01

    Excessive lead exposure in shooting instructors at indoor firing ranges and covered outdoor firing ranges has been documented. The City of Los Angeles assessed exposure of its full-time shooting instructors at uncovered outdoor ranges via air monitoring and blood lead-level measurements. Results of these tests revealed that significant lead exposure and absorption can occur at outdoor firing ranges. The use of copper-jacketed ammunition may decrease air lead levels and decrease lead absorption by range instructors.

  18. QUANTITATIVE EVALUATION OF FIRE SEPARATION AND BARRIERS

    SciTech Connect (OSTI)

    Coutts, D

    2007-04-17

    Fire barriers, and physical separation are key components in managing the fire risk in Nuclear Facilities. The expected performance of these features have often been predicted using rules-of-thumb or expert judgment. These approaches often lack the convincing technical bases that exist when addressing other Nuclear Facility accident events. This paper presents science-based approaches to demonstrate the effectiveness of fire separation methods.

  19. Slepian-Wolf coded nested quantization (SEC-NQ) for Wyner-Ziv coding: high-rate performance analysis, code design, and application to cooperative networks 

    E-Print Network [OSTI]

    Liu, Zhixin

    2009-05-15

    The upper capacity bound (4.6), the lower rate bound achievable with DF, the lower rate bound (4.14) achievable with CF, and the rate bound of multi-hop transmission, as functions of c 2 sr when P r = P s = 5 dB, c 2 sd = 0 dB, and c 2 rd = 10 d....r.t. e and y d1 , with d =9m, c 2 sr =1.4? 10 ?7 ,andP s1 =69.4dB. ................... 78 24 The additive noise upper bound of WZC rate and distortion, both as functions of ? 2 n ,wherec 2 sr =1.4 ? 10 ?7 (i.e., the relay is 9m away from the source...

  20. Dynamics of fire plumes and smoke clouds associated with peat and deforestation fires in Indonesia

    E-Print Network [OSTI]

    Tosca, M. G; Randerson, J. T; Zender, C. S; Nelson, D. L; Diner, D. J; Logan, J. A

    2011-01-01

    analyses suggested that direct injection of smoke into the4. Discussion [ 38 ] Direct injection of fire emissions into

  1. Tracking New Coal-Fired Power Plants

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    January 8, 2010 National Energy Technology Laboratory Office of Systems Analyses and Planning Erik Shuster 2 Tracking New Coal-Fired Power Plants This report is intended to...

  2. EFFECTIVENESS OF REHABILITATION TREATMENTS IN REDUCING POST-FIRE EROSION AFTER THE HAYMAN AND SCHOONOVER FIRES,

    E-Print Network [OSTI]

    MacDonald, Lee

    THESIS EFFECTIVENESS OF REHABILITATION TREATMENTS IN REDUCING POST-FIRE EROSION AFTER THE HAYMAN OF REHABILITATION TREATMENTS IN REDUCING POST- FIRE EROSION AFTER THE HAYMAN AND SCHOONOVER FIRES, COLORADO FRONT and damage human resources such as reservoirs, roads, and structures. Burned area emergency rehabilitation

  3. Aalborg Universitet Coal-firing and biomass-firing in a 150kW swirl stabilized burner flow reactor

    E-Print Network [OSTI]

    Berning, Torsten

    Aalborg Universitet Coal-firing and biomass-firing in a 150kW swirl stabilized burner flow reactor). Coal-firing and biomass-firing in a 150kW swirl stabilized burner flow reactor. Poster session-fired boiler could be far more challenging beca se b rner aerod namicsmore challenging, because burner

  4. Development and Testing of Industrial Scale Coal Fired Combustion System, Phase 3

    SciTech Connect (OSTI)

    Bert Zauderer

    1998-09-30

    Coal Tech Corp's mission is to develop, license & sell innovative, lowest cost, solid fuel fired power systems & total emission control processes using proprietary and patented technology for domestic and international markets. The present project 'DEVELOPMENT & TESTING OF INDUSTRIAL SCALE, COAL FIRED COMBUSTION SYSTEM, PHASE 3' on DOE Contract DE-AC22-91PC91162 was a key element in achieving this objective. The project consisted of five tasks that were divided into three phases. The first phase, 'Optimization of First Generation 20 MMBtu/hr Air-Cooled Slagging Coal Tech Combustor', consisted of three tasks, which are detailed in Appendix 'A' of this report. They were implemented in 1992 and 1993 at the first generation, 20 MMBtu/hour, combustor-boiler test site in Williamsport, PA. It consisted of substantial combustor modifications and coal-fired tests designed to improve the combustor's wall cooling, slag and ash management, automating of its operation, and correcting severe deficiencies in the coal feeding to the combustor. The need for these changes was indicated during the prior 900-hour test effort on this combustor that was conducted as part of the DOE Clean Coal Program. A combination of combustor changes, auxiliary equipment changes, sophisticated multi-dimensional combustion analysis, computer controlled automation, and series of single and double day shift tests totaling about 300 hours, either resolved these operational issues or indicated that further corrective changes were needed in the combustor design. The key result from both analyses and tests was that the combustor must be substantially lengthened to maximize combustion efficiency and sharply increase slag retention in the combustor. A measure of the success of these modifications was realized in the third phase of this project, consisting of task 5 entitled: 'Site Demonstration with the Second Generation 20 MMBtu/hr Air-Cooled Slagging Coal Tech Combustor'. The details of the task 5 effort are contained in Appendix 'C'. It was implemented between 1994 and 1998 after the entire 20 MMBtu/hr combustor-boiler facility was relocated to Philadelphia, PA in 1994. A new test facility was designed and installed. A substantially longer combustor was fabricated. Although not in the project plan or cost plan, an entire steam turbine-electric power generating plant was designed and the appropriate new and used equipment for continuous operation was specified. Insufficient funds and the lack of a customer for any electric power that the test facility could have generated prevented the installation of the power generating equipment needed for continuous operation. All other task 5 project measures were met and exceeded. 107 days of testing in task 5, which exceeded the 63 days (about 500 hours) in the test plan, were implemented. Compared to the first generation 20 MMBtu/hr combustor in Williamsport, the 2nd generation combustor has a much higher combustion efficiency, the retention of slag inside the combustor doubled to about 75% of the coal ash, and the ash carryover into the boiler, a major problem in the Williamsport combustor was essentially eliminated. In addition, the project goals for coal-fired emissions were exceeded in task 5. SO{sub 2} was reduced by 80% to 0.2 lb/MMBtu in a combination of reagent injection in the combustion and post-combustion zones. NO{sub x} was reduced by 93% to 0.07 lb/MMBtu in a combination of staged combustion in the combustor and post-combustion reagent injection. A baghouse was installed that was rated to 0.03 lb/MMBtu stack particle emissions. The initial particle emission test by EPA Method 5 indicated substantially higher emissions far beyond that indicated by the clear emission plume. These emissions were attributed to steel particles released by wall corrosion in the baghouse, correction of which had no effect of emissions.

  5. Fire Resources | Open Energy Information

    Open Energy Info (EERE)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on QA:QA J-E-1 SECTION J APPENDIX ECoopButtePowerEdistoWhiskey flats 100k.pdf Jump to:WindP.pdfFire Resources Jump to:

  6. UC leads effort to protect California forests from catastrophic fire

    E-Print Network [OSTI]

    Warnert, Jeannette E

    2012-01-01

    forests from catastrophic fire F ire has always been a partthe past 100 years, a national fire suppression policy hasthe natural order. “By studying fire scars on tree rings,

  7. Annual Fire Protection Program Summary for Calendar Year 2012...

    Broader source: Energy.gov (indexed) [DOE]

    DOE experienced no fire-related fatalities, but three off-site firefighters from the nearby Manorville fire department were injured during a BNL range fire on April 9, 2012. There...

  8. Fire Interactions and Pulsation - Theoretical and Physical Modeling

    E-Print Network [OSTI]

    Maynard, Trevor

    2013-01-01

    Koonce, Int. J. Wildland Fire 1 (1991) 153-158. C.C Hardy,of flames from separate fuel beds. Fire Research Note 551.Boreham Wood Fire Research Station. (Boreham Wood,

  9. Game-Method Model for Field Fires Nina Dobrinkova1

    E-Print Network [OSTI]

    Fidanova, Stefka

    Engineering, Bulgarian Academy of Sciences krat@bas.bg Abstract. Every year about 45000 forest fires occur fire. This model can be used also by non specialist in the forest fires field for learn- ing

  10. UC leads effort to protect California forests from catastrophic fire

    E-Print Network [OSTI]

    Warnert, Jeannette E

    2012-01-01

    because of its Humans and forest fire credibility on allof the 20th century, natural forest fires out forest fuelsto make Sierra Nevada forests more fire resil- ient is an

  11. Global burned area and biomass burning emissions from small fires

    E-Print Network [OSTI]

    Randerson, J. T; Chen, Y.; van der Werf, G. R; Rogers, B. M; Morton, D. C

    2012-01-01

    emissions from Canadian forest fires, 1959–1999, Can. J.released from peat and forest fires in Indo- nesia duringSpatial patterns of forest fires in Canada, 1980–1999, Int.

  12. The Impact of Boreal Forest Fire on Climate Warming

    E-Print Network [OSTI]

    2006-01-01

    The Impact of Boreal Forest Fire on Climate Warming J. T.analysis of a boreal forest fire, integrating the effects ofnet effect of a boreal forest fire on climate, on the basis

  13. Live Fire Range Environmental Assessment

    SciTech Connect (OSTI)

    1993-08-01

    The Central Training Academy (CTA) is a DOE Headquarters Organization located in Albuquerque, New Mexico, with the mission to effectively and efficiently educate and train personnel involved in the protection of vital national security interests of DOE. The CTA Live Fire Range (LFR), where most of the firearms and tactical training occurs, is a complex separate from the main campus. The purpose of the proposed action is to expand the LFR to allow more options of implementing required training. The Department of Energy has prepared this Environmental Assessment (EA) for the proposed construction and operation of an expanded Live Fire Range Facility at the Central Training Academy in Albuquerque, New Mexico. Based on the analysis in the EA, DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment, within the meaning of the National Environmental Policy Act (NEPA) of 1969. Therefore, the preparation of an environmental impact statement is not required and DOE is issuing this Finding of No Significant Impact (FONSI).

  14. Global fire emissions and the contribution of deforestation, savanna, forest, agricultural, and peat fires (1997-2009)

    E-Print Network [OSTI]

    2010-01-01

    released from peat and forest fires in Indonesia duringZhang, Y. H. : Boreal forest fires burn less in- tensely inemissions from boreal forest fires, J. Geophys. Res. -Atmos,

  15. Global fire emissions and the contribution of deforestation, savanna, forest, agricultural, and peat fires (1997-2009)

    E-Print Network [OSTI]

    2010-01-01

    in Canadian boreal forest fires, Can. J. Forest Res. , 39,emissions from boreal forest fires, J. Geophys. Res. -Atmos,released from peat and forest fires in Indonesia during

  16. Fire Department Gets New Trucks, Saves Money

    Broader source: Energy.gov [DOE]

    RICHLAND, Wash. – Last year, the Hanford Fire Department (HFD) set out to replace its aging chemical truck used for metal fires. Originally purchased to respond to potential incidents at the Fast Flux Test Facility, the 31-year-old vehicle was at the end of its lifecycle.

  17. Annual Fire Safety Report For Student Housing

    E-Print Network [OSTI]

    Baltisberger, Jay H.

    and electrically wired smoke detectors with battery backups are located in individual living units have battery back-ups. Evacuation Procedures Students must evacuate during a fire alarm and proceed environment, free from known fire hazards. The college's goal is to recognize hazardous conditions and take

  18. Carbon Dioxide Capture from Coal-Fired

    E-Print Network [OSTI]

    Carbon Dioxide Capture from Coal-Fired Power Plants: A Real Options Analysis May 2005 MIT LFEE 2005. LFEE 2005-002 Report #12;#12;i ABSTRACT Investments in three coal-fired power generation technologies environment. The technologies evaluated are pulverized coal (PC), integrated coal gasification combined cycle

  19. Characterisation of Dalmarnock Fire Test One 

    E-Print Network [OSTI]

    Abecassis Empis, Cecilia; Reszka, Pedro; Steinhaus, Thomas; Cowlard, Adam; Biteau, Hubert; Welch, Stephen; Rein, Guillermo; Torero, Jose L

    2008-01-01

    The Dalmarnock Tests comprise a set of fire experiments conducted in a real high-rise building in July 2006. The two main tests took place in identical flats, Test One allowing the fire to develop freely to post-flashover ...

  20. UNIVERSITY OF WASHINGTON FIRE DRILL REPORT

    E-Print Network [OSTI]

    Matrajt, Graciela

    UNIVERSITY OF WASHINGTON FIRE DRILL REPORT ENVIRONMENTAL HEALTH AND SAFETY Building Name Facility or Building Administrator/Coordinator Date of Drill Device Activated (location) Time Initiated Time Completed Verify that all procedures for preparing and conducting fire drills have been completed. Do not activate

  1. Risk assessment compatible fire models (RACFMs)

    SciTech Connect (OSTI)

    Lopez, A.R.; Gritzo, L.A.; Sherman, M.P.

    1998-07-01

    A suite of Probabilistic Risk Assessment Compatible Fire Models (RACFMs) has been developed to represent the hazard posed by a pool fire to weapon systems transported on the B52-H aircraft. These models represent both stand-off (i.e., the weapon system is outside of the flame zone but exposed to the radiant heat load from fire) and fully-engulfing scenarios (i.e., the object is fully covered by flames). The approach taken in developing the RACFMs for both scenarios was to consolidate, reconcile, and apply data and knowledge from all available resources including: data and correlations from the literature, data from an extensive full-scale fire test program at the Naval Air Warfare Center (NAWC) at China Lake, and results from a fire field model (VULCAN). In the past, a single, effective temperature, T{sub f}, was used to represent the fire. The heat flux to an object exposed to a fire was estimated using the relationship for black body radiation, {sigma}T{sub f}{sup 4}. Significant improvements have been made by employing the present approach which accounts for the presence of temperature distributions in fully-engulfing fires, and uses best available correlations to estimate heat fluxes in stand-off scenarios.

  2. Fire and explosion hazards of oil shale

    SciTech Connect (OSTI)

    Not Available

    1989-01-01

    The US Bureau of Mines publication presents the results of investigations into the fire and explosion hazards of oil shale rocks and dust. Three areas have been examined: the explosibility and ignitability of oil shale dust clouds, the fire hazards of oil shale dust layers on hot surfaces, and the ignitability and extinguishment of oil shale rubble piles. 10 refs., 54 figs., 29 tabs.

  3. Managing Imported Fire Ants in Urban Areas 

    E-Print Network [OSTI]

    Drees, Bastiaan M.

    2006-08-17

    The imported fire ant is found in much of Texas and across the southeastern U.S. This publication describes options for managing the pest in specific locations such as home lawns, gardens and buildings. Other topics include fire ant treatment...

  4. FIRE AND CLIMATE CHANGE IN CALIFORNIA

    E-Print Network [OSTI]

    Moritz, Max A.

    's California Climate Change Center JULY 2012 CEC5002012026 Prepared for: California Energy Commission FIRE AND CLIMATE CHANGE IN CALIFORNIA Changes in the Distribution and Frequency of Fire the University of California, Davis, provided downscaling and hydrologic modeling of climate data

  5. Dispersion modeling of mercury emissions from coal-fired power plants at Coshocton and Manchester, Ohio

    SciTech Connect (OSTI)

    Lee, S.; Keener, T.C. [University of Cincinnati, Cincinnati, OH (United States). Dept. of Civil and Environmental Engineering

    2009-09-15

    Mercury emissions from coal-fired power plants are estimated to contribute to approximately 46% of the total US anthropogenic mercury emissions and required to be regulated by maximum achievable control technology (MACT) standards. Dispersion modeling of mercury emissions using the AERMOD model and the industrial source complex short term (ISCST3) model was conducted for two representative coal-fired power plants at Coshocton and Manchester, Ohio. Atmospheric mercury concentrations, dry mercury deposition rates, and wet mercury deposition rates were predicted in a 5 x 5 km area surrounding the Coonesville and JM Stuart coal-fired power plants. In addition, the analysis results of meteorological parameters showed that wet mercury deposition is dependent on precipitation, but dry mercury deposition is influenced by various meteorological factors. 8 refs., 5 figs., 3 tabs.

  6. The Biswell Symposium: Fire Issues and Solutions in Urban Interface and Wildland

    E-Print Network [OSTI]

    . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Jim Desmond FARSITE: A Fire Area Simulator for Fire Managers

  7. United States Department of Energy`s reactor core protection evaluation methodology for fires at RBMK and VVER nuclear power plants. Revision 1

    SciTech Connect (OSTI)

    1997-06-01

    This document provides operators of Soviet-designed RBMK (graphite moderated light water boiling water reactor) and VVER (pressurized light water reactor) nuclear power plants with a systematic Methodology to qualitatively evaluate plant response to fires and to identify remedies to protect the reactor core from fire-initiated damage.

  8. et al. 2003). Seasonal drought and extreme wind events make the WUI especially susceptible to fire. In late October, 2003, Southern California experienced the worst

    E-Print Network [OSTI]

    Moritz, Max A.

    . The Wildland-Urban Interface Evacuation (WUIVAC) model is designed to help decision-makers set fire evacu#12;et al. 2003). Seasonal drought and extreme wind events make the WUI especially susceptible. Multiple large wildfires driven by Santa Ana winds consumed more than 300,000 ha. These fires were

  9. Heat Recovery Design Considerations for Cogeneration Systems 

    E-Print Network [OSTI]

    Pasquinelli, D. M.; Burns, E. D.

    1985-01-01

    The design and integration of the heat recovery section, which includes the steam generation, auxiliary firing, and steam turbine modules, is critical to the overall performance and economics of cogeneration, systems. In gas turbine topping...

  10. Moving Beyond Prevailing Street Design Standards

    E-Print Network [OSTI]

    Kammen, Daniel M.

    12 The California Fire Code and other state laws 12 Local policies and design standards 14 Case law like to thank the Fresno and Sacramento city officials who took the time to share valuable information

  11. Feasibility of methods and systems for reducng LNG tanker fire hazards

    SciTech Connect (OSTI)

    Not Available

    1980-08-01

    In this program concepts for reducing fire hazards that may result from LNG tanker collisions are identified and their technical feasibility evaluated. Concepts considered include modifications to the shipborne LNG containers so that in the event of a container rupture less of the contents would spill and/or the contents would spill at a reduced rate. Changes in the cargo itself, including making the LNG into a gel, solidifying it, converting it to methanol, and adding flame suppressants are also evaluated. The relative effectiveness and the costs of implementing these methods in terms of increased cost of gas at the receiving terminal, are explained. The vulnerability of an LNG tanker and its crew to the thermal effects of a large pool fire caused by a collision spill is estimated and methods of protecting the crew are considered. It is shown that the protection of ship and crew so that further deterioration of a damaged ship might be ameliorated, would require the design and installation of extraordinary insulation systems and life support assistance for the crew. Methods of salvaging or disposing of cargo from a damaged and disabled ship are evaluated, and it is concluded that if the cargo cannot be transferred to another (empty) LNG tanker because of lack of availability, then the burning of the cargo at a location somewhat distant from the disabled tanker appears to be a promising approach. Finally, the likelihood of the vapors from a spill being ignited due to the frictional impact of the colliding ships was examined. It is found that the heating of metal sufficient to ignite flammable vapors would occur during a collision, but it is questionable whether flammable vapor and air will, in fact, come in contact with the hot metal surfaces.

  12. Burner Designs and Controls for Variable Air Preheat Systems 

    E-Print Network [OSTI]

    Lied, C. R.

    1981-01-01

    This paper will deal with various ways of reducing fuel costs for direct fired furnaces. Burner design relating to existing furnaces, new furnaces designed to operate initially on cold air with the ability to add preheated air in the future...

  13. DEVELOPMENT OF BURN TEST SPECIFICATIONS FOR FIRE PROTECTION MATERIALS IN RAM PACKAGES

    SciTech Connect (OSTI)

    Gupta, N.

    2010-03-03

    The regulations in 10 CFR 71 require that the radioactive material (RAM) packages must be able to withstand specific fire conditions given in 10 CFR 71.73 during Hypothetical Accident Conditions (HAC). This requirement is normally satisfied by extensive testing of full scale test specimens under required test conditions. Since fire test planning and execution is expensive and only provides a single snapshot into a package performance, every effort is made to minimize testing and supplement tests with results from computational thermal models. However, the accuracy of such thermal models depends heavily on the thermal properties of the fire insulating materials that are rarely available at the regulatory fire temperatures. To the best of authors knowledge no test standards exist that could be used to test the insulating materials and derive their thermal properties for the RAM package design. This paper presents a review of the existing industry fire testing standards and proposes testing methods that could serve as a standardized specification for testing fire insulating materials for use in RAM packages.

  14. THERMAL ANALYSIS OF A 9975 PACKAGE IN A FACILITY FIRE ACCIDENT

    SciTech Connect (OSTI)

    Gupta, N.

    2011-02-14

    Surplus plutonium bearing materials in the U.S. Department of Energy (DOE) complex are stored in the 3013 containers that are designed to meet the requirements of the DOE standard DOE-STD-3013. The 3013 containers are in turn packaged inside 9975 packages that are designed to meet the NRC 10 CFR Part 71 regulatory requirements for transporting the Type B fissile materials across the DOE complex. The design requirements for the hypothetical accident conditions (HAC) involving a fire are given in 10 CFR 71.73. The 9975 packages are stored at the DOE Savannah River Site in the K-Area Material Storage (KAMS) facility for long term of up to 50 years. The design requirements for safe storage in KAMS facility containing multiple sources of combustible materials are far more challenging than the HAC requirements in 10 CFR 71.73. While the 10 CFR 71.73 postulates an HAC fire of 1475 F and 30 minutes duration, the facility fire calls for a fire of 1500 F and 86 duration. This paper describes a methodology and the analysis results that meet the design limits of the 9975 component and demonstrate the robustness of the 9975 package.

  15. Temperature and heat flux datasets of a complex object in a fire plume for the validation of fire and thermal response codes.

    SciTech Connect (OSTI)

    Jernigan, Dann A.; Blanchat, Thomas K.

    2010-09-01

    It is necessary to improve understanding and develop temporally- and spatially-resolved integral scale validation data of the heat flux incident to a complex object in addition to measuring the thermal response of said object located within the fire plume for the validation of the SIERRA/FUEGO/SYRINX fire and SIERRA/CALORE codes. To meet this objective, a complex calorimeter with sufficient instrumentation to allow validation of the coupling between FUEGO/SYRINX/CALORE has been designed, fabricated, and tested in the Fire Laboratory for Accreditation of Models and Experiments (FLAME) facility. Validation experiments are specifically designed for direct comparison with the computational predictions. Making meaningful comparison between the computational and experimental results requires careful characterization and control of the experimental features or parameters used as inputs into the computational model. Validation experiments must be designed to capture the essential physical phenomena, including all relevant initial and boundary conditions. This report presents the data validation steps and processes, the results of the penlight radiant heat experiments (for the purpose of validating the CALORE heat transfer modeling of the complex calorimeter), and the results of the fire tests in FLAME.

  16. Self-Organized Forest-Fires near the Critical Time

    E-Print Network [OSTI]

    J. van den Berg; R. Brouwer

    2004-12-24

    We consider a forest-fire model which, somewhat informally, is described as follows: Each site (vertex) of the square lattice is either vacant or occupied by a tree.Vacant sites become occupied at rate 1. Further, each site is hit by lightningat rate lambda. This lightning instantaneously destroys (makes vacant) the occupied cluster of the site. This model is closely related to the Drossel-Schwabl forest-fire model, which has received much attention in the physics literature. The most interesting behaviour seems to occur when the lightning rate goes to zero. In the physics literature it is believed that then the system has so-called self-organized critical behaviour. We let the system start with all sites vacant and study, for positive but small lambda,the behaviour near the `critical time' tc; that is, the time after which in the modified system without lightning an infinite occupied cluster would emerge. Intuitively one might expect that if, for fixed t > tc, we let simultaneously lambda tend to 0 and m to infinity, the probability that some tree at distance smaller than m from O is burnt before time t goes to 1. However, we show that under a percolation-like assumption (which we can not prove but believe to be true) this intuition is false. We compare with the case where the square lattice is replaced by the directed binary tree, and pose some natural open problems.

  17. Analysis of RHIC beam dump pre-fires

    SciTech Connect (OSTI)

    Zhang, W.; Ahrens, L.; Fischer, W.; Hahn, H.; Mi, J.; Sandberg, J.; Tan, Y.

    2011-03-28

    It has been speculated that the beam may cause instability of the RHIC Beam Abort Kickers. In this study, we explore the available data of past beam operations, the device history of key modulator components, and the radiation patterns to examine the correlations. The RHIC beam abort kicker system was designed and built in the 90's. Over last decade, we have made many improvements to bring the RHIC beam abort kicker system to a stable operational state. However, the challenge continues. We present the analysis of the pre-fire, an unrequested discharge of kicker, issues which relates to the RHIC machine safety and operational stability.

  18. ARM - Field Campaign - ARM-FIRE Water Vapor Experiment

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach HomeA Better Anode Design to Improve4AJ01) (See22, 2012III ARM DatagovCampaignsARM-FIRE Water Vapor

  19. ARM - Field Campaign - FIRE-Arctic Cloud Experiment/SHEBA

    Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Homesum_a_epg0_fpd_mmcf_m.xls" ,"Available from WebQuantity ofkandz-cm11 Outreach HomeA Better Anode Design to Improve4AJ01)govCampaignsFIRE-Arctic Cloud Experiment/SHEBA ARM Data

  20. Thermal Integration of CO{sub 2} Compression Processes with Coal-Fired Power Plants Equipped with Carbon Capture

    SciTech Connect (OSTI)

    Edward Levy

    2012-06-29

    Coal-fired power plants, equipped either with oxycombustion or post-combustion CO{sub 2} capture, will require a CO{sub 2} compression system to increase the pressure of the CO{sub 2} to the level needed for sequestration. Most analyses show that CO{sub 2} compression will have a significant effect on parasitic load, will be a major capital cost, and will contribute significantly to reduced unit efficiency. This project used first principle engineering analyses and computer simulations to determine the effects of utilizing compressor waste heat to improve power plant efficiency and increase net power output of coal-fired power plants with carbon capture. This was done for units with post combustion solvent-based CO{sub 2} capture systems and for oxyfired power plants, firing bituminous, PRB and lignite coals. The thermal integration opportunities analyzed for oxycombustion capture are use of compressor waste heat to reheat recirculated flue gas, preheat boiler feedwater and predry high-moisture coals prior to pulverizing the coal. Among the thermal integration opportunities analyzed for post combustion capture systems are use of compressor waste heat and heat recovered from the stripper condenser to regenerate post-combustion CO{sub 2} capture solvent, preheat boiler feedwater and predry high-moisture coals. The overall conclusion from the oxyfuel simulations is that thermal integration of compressor heat has the potential to improve net unit heat rate by up to 8.4 percent, but the actual magnitude of the improvement will depend on the type of heat sink used and to a lesser extent, compressor design and coal rank. The simulations of a unit with a MEA post combustion capture system showed that thermal integration of either compressor heat or stripper condenser heat to preheat boiler feedwater would result in heat rate improvements from 1.20 percent to 4.19 percent. The MEA capture simulations further showed that partial drying of low rank coals, done in combination with feedwater heating, would result in heat rate reductions of 7.43 percent for PRB coal and 10.45 percent for lignite.

  1. Virtual Reality Simulation of Fire Fighting Robot Dynamic and Motion

    E-Print Network [OSTI]

    Setiawan, Joga D; Budiyono, Agus

    2008-01-01

    This paper presents one approach in designing a Fire Fighting Robot which has been contested annually in a robotic student competition in many countries following the rules initiated at the Trinity College. The approach makes use of computer simulation and animation in a virtual reality environment. In the simulation, the amount of time, starting from home until the flame is destroyed, can be confirmed. The efficacy of algorithms and parameter values employed can be easily evaluated. Rather than spending time building the real robot in a trial and error fashion, now students can explore more variation of algorithm, parameter and sensor-actuator configuration in the early stage of design. Besides providing additional excitement during learning process and enhancing students understanding to the engineering aspects of the design, this approach could become a useful tool to increase the chance of winning the contest.

  2. Material Analysis for a Fire Assessment.

    SciTech Connect (OSTI)

    Brown, Alexander; Nemer, Martin

    2014-08-01

    This report consolidates technical information on several materials and material classes for a fire assessment. The materials include three polymeric materials, wood, and hydraulic oil. The polymers are polystyrene, polyurethane, and melamine- formaldehyde foams. Samples of two of the specific materials were tested for their behavior in a fire - like environment. Test data and the methods used to test the materials are presented. Much of the remaining data are taken from a literature survey. This report serves as a reference source of properties necessary to predict the behavior of these materials in a fire.

  3. Method of locating underground mines fires

    DOE Patents [OSTI]

    Laage, Linneas (Eagam, MN); Pomroy, William (St. Paul, MN)

    1992-01-01

    An improved method of locating an underground mine fire by comparing the pattern of measured combustion product arrival times at detector locations with a real time computer-generated array of simulated patterns. A number of electronic fire detection devices are linked thru telemetry to a control station on the surface. The mine's ventilation is modeled on a digital computer using network analysis software. The time reguired to locate a fire consists of the time required to model the mines' ventilation, generate the arrival time array, scan the array, and to match measured arrival time patterns to the simulated patterns.

  4. Wildland Fire Risk and Management on West and South Ranges

    E-Print Network [OSTI]

    #12;#12;Wildland Fire Risk and Management on West and South Ranges Schofield Barracks, Oahu March) Intermountain Fire Science Lab, Missoula, MT CEMML TPS01-11 #12;#12;Wildland Fire Risk and Management on West .................................................................................................................................. 1 Fire Characteristics of Common Species

  5. If a fire should occur... CLOSE the doors to

    E-Print Network [OSTI]

    Al Faruque, Mohammad Abdullah

    If a fire should occur... · CLOSE the doors to stop the spread of the fire · SOUND the alarm, alert others to the danger · GET OUT of the building · NOTIFY the fire department DO NOT go back into the building or try to save your stuff. Clothes, books and papers can be replaced- YOU CAN'T! Living With Fire

  6. Forest Fire Modeling and Early Detection using Wireless Sensor Networks

    E-Print Network [OSTI]

    Zhang, Richard "Hao"

    Forest Fire Modeling and Early Detection using Wireless Sensor Networks MOHAMED HEFEEDA Simon Fraser University, Canada Forest fires cost millions of dollars in damages and claim many human lives for early detection of forest fires. We first present the key aspects in modeling forest fires. We do

  7. Post-Fire Vegetation Response 49 Barbara A. Holzman

    E-Print Network [OSTI]

    Bruns, Tom

    -Fire Vegetation Response in the Bishop Pine Forest at Point Reyes National Seashore Chinook helicopter dropping

  8. Forests, Foraging and Fires August 23November 12, 2014

    E-Print Network [OSTI]

    Barrash, Warren

    Forests, Foraging and Fires August 23­November 12, 2014 Forests, Foraging and Fires Catherine, Shannon Durbin is fascinated by the conflict between the role of fire in maintaining healthy forests beauty of forest fires." In the installation Thank You, Fog, Spencer Finch presents 60 photographs made

  9. LBTO Forest Fire Contingency Plan 5 Doc_info_start

    E-Print Network [OSTI]

    Ziurys, Lucy M.

    LBTO Forest Fire Contingency Plan 5 Doc_info_start Title: LBTO Forest Fire Contingency Plan: Date_of_Release: File Type: MS Word Local Name: LBTO Forest Fire Contingency Plan Category: Overview: 004s001 Revision: a Doc_info_end #12;LBTO Forest Fire Contingency Plan 4 TO SECURE THE LBTO ENCLOSURE

  10. Why Does the Sun Shine? Is the Sun on Fire?

    E-Print Network [OSTI]

    Walter, Frederick M.

    Why Does the Sun Shine? #12;Is the Sun on Fire? Fire (oxidation) produces light and heat, just like the Sun. Source: chemical potential energy Suppose the Sun were made of carbon and oxygen. ·The Sun could) * mp N = M / MCO2 = 2.6 X 1055 (number of reactions possible) #12;Is the Sun on Fire? Fire produces

  11. Why Does the Sun Shine? Is the Sun on Fire?

    E-Print Network [OSTI]

    Walter, Frederick M.

    Why Does the Sun Shine? #12;Is the Sun on Fire? Fire (oxidation) produces light and heat, just like the Sun. Source: chemical potential energy Suppose the Sun were made of carbon and oxygen. · The Sun could) * mp N = M¤ / MCO2 = 2.6 X 1055 (number of reactions possible) #12;Is the Sun on Fire? Fire produces

  12. COMPARING SIMULATION METHODS FOR FIRE SPREADING ACROSS A FUEL BED

    E-Print Network [OSTI]

    Wainer, Gabriel

    choice to solve the problem. Diffusion processes (oil spills, fire spread, insect infestation, etcCOMPARING SIMULATION METHODS FOR FIRE SPREADING ACROSS A FUEL BED Alexandre Muzy Computer Modeling computer simulation of a semi-physical fire spread model. Forest fire is a com- plex phenomenon, which

  13. FIRE CHITS, Superchits, and Comments from Engineering Review of June, 2001

    E-Print Network [OSTI]

    new insulator configurations that employ inorganic insulator cuffs in the high radiation dose/low of full power shots is limited by radiation damage of insulators. More shielding between plasma and inner Research & Development Plan", Aug 15, 2001 DESIGN PT - PHYSICS & TRADE STUDIES Page 1 #12;FIRE CHITS

  14. Analytical and experimental evaluation of solid waste drum fire performance volumes I and II

    SciTech Connect (OSTI)

    Hecker, C.F.,; Rhodes, B.T.; Beitel, J.J.; Gottuk, D.T.; Beyler, C.L.; Rosenbaum, E.R.,

    1995-04-28

    Fire hazards associated with drum storage of radioactively contaminated wastes are a major concern in DOE facilities design for long term storage of solid wastes in drums. These facilities include drums stored in pallet arrays and in rack storage systems. This report details testing in this area

  15. An Inexpensive Ohmic Transformer Firing Circuit for the CDXU Spherical Torus

    E-Print Network [OSTI]

    1 An Inexpensive Ohmic Transformer Firing Circuit for the CDX­U Spherical Torus T. Munsat, R designed and modeled a simple, efficient circuit for delivering power to the CDX­U ohmic transformer, spherical tori) have traditionally driven plasma current by using the transformer action of a centrally

  16. An Inexpensive Ohmic Transformer Firing Circuit for the CDX-U Spherical Torus

    E-Print Network [OSTI]

    1 An Inexpensive Ohmic Transformer Firing Circuit for the CDX-U Spherical Torus T. Munsat, R designed and modeled a simple, efficient circuit for delivering power to the CDX-U ohmic transformer, spherical tori) have traditionally driven plasma current by using the transformer action of a centrally

  17. Reduction of fire hazards on large mining equipment

    SciTech Connect (OSTI)

    Maria I. De Rosa

    2008-09-15

    Although standards and regulations are in place to prevent large mining equipment fires, recent analyses of mine accident data show that mining equipment fires still occur with alarming frequency and grave consequences, particularly at all surface mines and in underground metal/nonmetal mines. Recently technological advances in fire protection, combined with the statistical data on equipment fires, led NIOSH to reinvestigate this and to improve operator safety. NIOSH demonstrated that newly developed technologies, such as dual cab fire inerting systems and engine compartment fire barriers, can greatly enhance operator safety and lessen the damage of property during large mobile equipment fires. 10 refs., 5 figs.

  18. Computerized fire modeling as an effective tool for glovebox fire safety

    SciTech Connect (OSTI)

    Not Available

    1989-01-01

    In 1986, DOE instituted a program of intense audits by outside safety experts as a result of increased awareness of safety related issues. These audits were referred to as (TSA's). In 1988, a third TSA was conducted of one of the major production buildings. One of the findings of a Technical Safety Appraisal (TSA) was that at Rocky Flats fire dampers are not installed within HVAC ductwork where the duct passes through fire barrier walls. Fire dampers are not utilized in ductwork because the exhaust air flow from process areas is critical from a radiological containment standpoint. Without adequate exhaust during a postulated fire, there would be the potential for radiological contamination exterior to the building. Due to this is an intolerable situation, fire dampers are not utilized. The final solution investigated was to attack the problem through the use of a computerized fire model of critical fire areas. The fact that fuel loading in most production areas was very low (3 to 7 pounds per square foot) led to the hypothesis that insufficient fire intensity exists to cause collapse of the duct. In order to validate this approach, two critical elements were needed. The first was a method to postulate a fire in the fire areas'' and the second was to determine at what exact point ducts will actually collapse. The best approach for the first element was through the use of a computerized fire model. The second element approach would be through either sound full scale fire testing or through a complete research search of past tests.

  19. Wildland Fire Management Plan for Brookhaven National Laboratory

    SciTech Connect (OSTI)

    Schwager, K.; Green, T. M.

    2014-10-01

    The DOE policy for managing wildland fires requires that all areas managed by DOE and/or Its various contractors which can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wildland fire, operational, and prescribed fires. FMPs provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled ''prescribed'' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. The plan will be reviewed periodically to ensure fire program advances and will evolve with the missions of DOE and BNL.

  20. Posteriori Modelling of Fire Test One 

    E-Print Network [OSTI]

    Jahn, Wolfram; Rein, Guillermo; Torero, Jose L

    2007-10-14

    This work shows that reproducing fire behaviour of a full-scale enclosure on a detailed level using CFD simulations is possible to certain degree but is a very challenging task. A posteriori (ie after the test) numerical ...

  1. A New Approach to Optimizing Fired Heaters 

    E-Print Network [OSTI]

    Garg, A.

    2010-01-01

    Fired heaters are the largest consumers of energy in refineries and petrochemical plants. Most heaters in the industry are not operating at their peak efficiency. There could be several reasons for that. One of the common reasons is the fluctuation...

  2. Experiments and Observation of Peat Smouldering Fires 

    E-Print Network [OSTI]

    Ashton, Clare; Rein, Guillermo; Dios, JD; Torero, Jose L; Legg, C; Davies, M; Gray, A

    2007-01-30

    If a subsurface layer of peat is ignited, it smoulders (flameless combustion) slowly but steadily. These fires propagate for long periods of time (days, weeks, even years), are particularly difficult to extinguish and can ...

  3. Tall building collapse mechanisms initiated by fire 

    E-Print Network [OSTI]

    Usmani, Asif; Roben, Charlotte; Johnston, Louise; Flint, Graeme

    This paper introduces the hypothesis of two possible failure mechanisms for tall buildings in multiple floor fires. This paper extends the previous work done on the WTC towers by investigating more "generic" tall building frames made of standard...

  4. One-dimensional general forest fire processes

    E-Print Network [OSTI]

    Bressaud, Xavier

    2011-01-01

    We consider the one-dimensional generalized forest fire process: at each site of $\\zz$, seeds and matches fall according some i.i.d. stationary renewal processes. When a seed falls on an empty site, a tree grows immediately. When a match falls on an occupied site, a fire starts and destroys immediately the corresponding connected component of occupied sites. Under some quite reasonable assumptions on the renewal processes, we show that when matches become less and less frequent, the process converges, with a correct normalization, to a limit forest fire model. According to the nature of the renewal processes governing seeds, there are four possible limit forest fire models. The four limit processes can be perfectly simulated. This study generalizes consequently a previous result of the authors where seeds and matches were assumed to fall according to Poisson processes.

  5. Understanding Fire Fighting in New Product Development

    E-Print Network [OSTI]

    Repenning, Nelson

    Despite documented benefits, the processes described in the new product development literature often prove difficult to follow in practice. A principal source of such difficulties is the phenomenon of fire fighting the ...

  6. Fire Imposed Heat Fluxes for Structural Analysis 

    E-Print Network [OSTI]

    Jowsey, Allan

    The last two decades have seen new insights, data and analytical methods to establish the behaviour of structures in fire. These methods have slowly migrated into practice and now form the basis for modern quantitative ...

  7. Fire Brigades costs and organisational arrangements 

    E-Print Network [OSTI]

    Hoyle, W.H.H.

    Basic cost curves for fire brigades in England and Wales are presented. The relationships are used to investigate the financial consequenoes of enlarging present brigade responsibilities in terms of the scope of service ...

  8. POST-FIRE REVEGETATION AT HANFORD

    SciTech Connect (OSTI)

    ROOS RC; JOHNSON AR; CAUDILL JG; RODRIGUEZ JM; WILDE JW

    2010-01-05

    Range fires on the Hanford Site can have a long lasting effect on native plant communities. Wind erosion following removal of protective vegetation from fragile soils compound the damaging effect of fires. Dust storms caused by erosion create health and safety hazards to personnel, and damage facilities and equipment. The Integrated Biological Control Program (IBC) revegetates burned areas to control erosion and consequent dust. Use of native, perennial vegetation in revegetation moves the resulting plant community away from fire-prone annual weeds, and toward the native shrub-steppe that is much less likely to burn in the future. Over the past 10 years, IBC has revegetated major fire areas with good success. IBC staff is monitoring the success of these efforts, and using lessons learned to improve future efforts.

  9. Coal-fired high performance power generating system. Final report

    SciTech Connect (OSTI)

    1995-08-31

    As a result of the investigations carried out during Phase 1 of the Engineering Development of Coal-Fired High-Performance Power Generation Systems (Combustion 2000), the UTRC-led Combustion 2000 Team is recommending the development of an advanced high performance power generation system (HIPPS) whose high efficiency and minimal pollutant emissions will enable the US to use its abundant coal resources to satisfy current and future demand for electric power. The high efficiency of the power plant, which is the key to minimizing the environmental impact of coal, can only be achieved using a modern gas turbine system. Minimization of emissions can be achieved by combustor design, and advanced air pollution control devices. The commercial plant design described herein is a combined cycle using either a frame-type gas turbine or an intercooled aeroderivative with clean air as the working fluid. The air is heated by a coal-fired high temperature advanced furnace (HITAF). The best performance from the cycle is achieved by using a modern aeroderivative gas turbine, such as the intercooled FT4000. A simplified schematic is shown. In the UTRC HIPPS, the conversion efficiency for the heavy frame gas turbine version will be 47.4% (HHV) compared to the approximately 35% that is achieved in conventional coal-fired plants. This cycle is based on a gas turbine operating at turbine inlet temperatures approaching 2,500 F. Using an aeroderivative type gas turbine, efficiencies of over 49% could be realized in advanced cycle configuration (Humid Air Turbine, or HAT). Performance of these power plants is given in a table.

  10. Wild Fire Computer Model Helps Firefighters

    SciTech Connect (OSTI)

    Canfield, Jesse

    2012-09-04

    A high-tech computer model called HIGRAD/FIRETEC, the cornerstone of a collaborative effort between U.S. Forest Service Rocky Mountain Research Station and Los Alamos National Laboratory, provides insights that are essential for front-line fire fighters. The science team is looking into levels of bark beetle-induced conditions that lead to drastic changes in fire behavior and how variable or erratic the behavior is likely to be.

  11. A Wood-Fired Gas Turbine Plant 

    E-Print Network [OSTI]

    Powell, S. H.; Hamrick, J. T.

    1986-01-01

    TURBINE PLANT Sam H. Powell, Tennessee Valley Authority, Chattanooga, Tennessee Joseph T. Hamrick, Aerospace Research Corporation, RBS Electric, Roanoke, VA Abstract This paper covers the research and development of a wood-fired gas turbine unit... of the walls. This wood?fired gas turbine unit could provide a low cost source of power for areas where conventional methods are now prohibitive and provide a means for recovering energy from a source that now poses disposal problems. When the Tennessee...

  12. Wild Fire Computer Model Helps Firefighters

    ScienceCinema (OSTI)

    Canfield, Jesse

    2014-06-02

    A high-tech computer model called HIGRAD/FIRETEC, the cornerstone of a collaborative effort between U.S. Forest Service Rocky Mountain Research Station and Los Alamos National Laboratory, provides insights that are essential for front-line fire fighters. The science team is looking into levels of bark beetle-induced conditions that lead to drastic changes in fire behavior and how variable or erratic the behavior is likely to be.

  13. Suppression of pool fires with HRC-125 in a simulated engine nacelle.

    SciTech Connect (OSTI)

    Keyser, David R. (INS, Inc., Lexington Park, MD); Hewson, John C.

    2007-06-01

    CFD simulations are conducted to predict the distribution of fire suppressant in an engine nacelle and to predict the suppression of pool fires by the application of this suppressant. In the baseline configuration, which is based on an installed system, suppressant is injected through four nozzles at a rate fast enough to suppress all simulated pool fires. Variations that reduce the mass of the suppression system (reducing the impact of the suppression system on meeting mission needs) are considered, including a reduction in the rate of suppressant injection, a reduction in the mass of suppressant and a reduction in the number of nozzles. In general, these variations should work to reduce the effectiveness of the suppression system, but the CFD results point out certain changes that have negligible impact, at least for the range of phenomena considered here. The results are compared with measurements where available. Comparisons with suppressant measurements are reasonable. A series of twenty-three fire suppression tests were conducted to check the predictions. The pre-test predictions were generally successful in identifying the range of successful suppression tests. In two separate cases, each where one nozzle of the suppression system was capped, the simulation results did indicate a failure to suppress for a condition where the tests indicated successful suppression. When the test-suppressant discharge rate was reduced by roughly 25%, the tests were in agreement with the predictions. That is, the simulations predict a failure to suppress slightly before observed in these cases.

  14. Firefighting and fire prevention: Facilities instructions, standards and techniques. Volume 5-2

    SciTech Connect (OSTI)

    Watson, H.E.

    1992-02-01

    The operation and maintenance personnel around a powerplant, pumping plant, or other Reclamation establishment are not presumed to be firefighters, but occasionally their duties may make it necessary for them to fight fires. The purpose of this volume is to supply them with fundamental facts which may prove valuable in such an emergency and acquaint them with the use, care, and testing of firefighting equipment. It is assumed that operation and maintenance personnel are familiar with the common safety practices in connection with fire prevention and general safety around electrical equipment. This volume is designed to help improve the work along these lines.

  15. Path Planning Algorithm for Extinguishing Forest Fires

    E-Print Network [OSTI]

    Kumar, M P Sivaram

    2012-01-01

    One of the major impacts of climatic changes is due to destroying of forest. Destroying of forest takes place in many ways but the majority of the forest is destroyed due to wild forest fires. In this paper we have presented a path planning algorithm for extinguishing fires which uses Wireless Sensor and Actor Networks (WSANs) for detecting fires. Since most of the works on forest fires are based on Wireless Sensor Networks (WSNs) and a collection of work has been done on coverage, message transmission, deployment of nodes, battery power depletion of sensor nodes in WSNs we focused our work in path planning approach of the Actor to move to the target area where the fire has occurred and extinguish it. An incremental approach is presented in order to determine the successive moves of the Actor to extinguish fire in an environment with and without obstacles. This is done by comparing the moves determined with target location readings obtained using sensors until the Actor reaches the target area to extinguish f...

  16. The impact of retail rate structures on the economics of commercial photovoltaic systems in California

    E-Print Network [OSTI]

    Mills, Andrew D.

    2009-01-01

    the impact of retail electricity rate design on the economiccustomer retail electricity rates currently offered in thethe design of retail electricity rates, particularly for

  17. The Impact of Retail Rate Structures on the Economics of Commercial Photovoltaic Systems in California

    E-Print Network [OSTI]

    Mills, Andrew

    2009-01-01

    the impact of retail electricity rate design on the economiccustomer retail electricity rates currently offered in thethe design of retail electricity rates, particularly for

  18. Spent Fuel Transportation Cask Response to the Caldecott Tunnel Fire Scenario

    SciTech Connect (OSTI)

    Adkins, Harold E.; Koeppel, Brian J.; Cuta, Judith M.

    2007-01-01

    On April 7, 1982, a tank truck and trailer carrying 8,800 gallons of gasoline was involved in an accident in the Caldecott tunnel on State Route 24 near Oakland, California. The tank trailer overturned and subsequently caught fire. The United States Nuclear Regulatory Commission (USNRC), one of the agencies responsible for ensuring the safe transportation of radioactive materials in the United States, undertook analyses to determine the possible regulatory implications of this particular event for the transportation of spent nuclear fuel by truck. The Fire Dynamics Simulator (FDS) code developed by National Institute of Standards and Technology (NIST) was used to determine the thermal environment in the Caldecott tunnel during the fire. The FDS results were used to define boundary conditions for a thermal transient model of a truck transport cask containing spent nuclear fuel. The Nuclear Assurance Corporation (NAC) Legal Weight Truck (LWT) transportation cask was selected for this evaluation, as it represents a typical truck (over-the-road) cask, and can be used to transport a wide variety of spent nuclear fuels. Detailed analysis of the cask response to the fire was performed using the ANSYS® computer code to evaluate the thermal performance of the cask design in this fire scenario. This report describes the methods and approach used to assess the thermal response of the selected cask design to the conditions predicted in the Caldecott tunnel fire. The results of the analysis are presented in detail, with an evaluation of the cask response to the fire. The staff concluded that some components of smaller transportation casks resembling the NAC LWT, despite placement within an ISO container, could degrade significantly. Small transportation casks similar to the NAC LWT would probably experience failure of seals in this severe accident scenario. USNRC staff evaluated the radiological consequences of the cask response to the Caldecott tunnel fire. Although some components heated up beyond their service temperatures, the staff determined that there would be no significant release as a result of the fire for the NAC LWT and similar casks.

  19. SHORT AND LONG-TERM FIRE IMPACTS ON HANFORD BARRIER PERFORMANCE

    SciTech Connect (OSTI)

    Ward, Anderson L.; Leary, Kevin D.; Link, Steven O.; Berlin, Gregory T.; Cammann, Jerry W.; Mandis, M. L.; Buelow, Laura C.

    2009-03-05

    A critical unknown in long-term engineered barrier use is the post-fire hydrologic function where institutional controls are in-tact but there are no resources to implement maintenance activities such as re-planting. This objective of this study was to simulate wild fire on an engineered barrier at the Hanford Site and document the post-fire changes in barrier performance. Soil physical, chemical, and hydrologic conditions; plant floristics and density; and animal use were characterized pre- and post-burn. Fuel load on the surface ranged from 4.7 to 5.71 tons/acre. Fire was initiated by drip torch and measurements of flame height and temperature were made at nine locations on the barrier surface. Flame heights exceeded 30 ft and temperatures ranged from 250 C at 1.5 cm below the surface to over 700 C at 1 m above the surface. Soil organic matter, soil wettability, and hydraulic conductivity all decreased significantly relative to pre-fire conditions. Post-fire samples showed an increase in major soil nutrients, pH, and electrical conductivity measured in 1:1 extracts whereas organic matter decreased. Decreases in wettabilty and organic matter are indicative of conditions more conducive to runoff and soil loss. The results of this study will contribute to a better understanding of post-fire recovery in a post-institutional control environment. This should lead to enhanced stakeholder acceptance regarding the long-term efficacy of ET barriers. This study will also support improvements in the design of ET barriers and performance monitoring systems. Such improvements are needed to best meet the long-term commitment to the safe in-place isolation of waste for hundreds if not thousands of years.

  20. Residence Hall Fire and Fire Alarm Procedures Page 1 of 3 Virginia Polytechnic Institute and State University No. 5605 Rev.: 3

    E-Print Network [OSTI]

    Residence Hall Fire and Fire Alarm Procedures Page 1 of 3 Virginia Polytechnic Institute and State ____________________________________________________________________________________ Subject: Residence Hall Fire and Fire Alarm Procedures ...........................................................................................................................2 1. Purpose Outlined below are the procedures to be followed should there be a fire alarm or fire

  1. Fire Safety Policy The College is a responsible employer that takes its fire safety duties seriously. For that1.1.

    E-Print Network [OSTI]

    Henderson, Gideon

    Fire Safety Policy 1. General The College is a responsible employer that takes its fire safety legal obligations to staff and visitors under the Regulatory Reform (Fire Safety) Order 2005 (The Order associated with fire b) Reduce the risk of an outbreak of fire c) Reduce the risk of the spread of fire d

  2. Status of PFC Design for FIRE January 17, 2001

    E-Print Network [OSTI]

    is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States if increases to allow room for the inner divertor. · Beware of subtle effects like pumping. · Limit the fusion

  3. DALHOUSIE UNIVERSITY Fire Protection Design Guidelines Nov 2013

    E-Print Network [OSTI]

    Brownstone, Rob

    that other options such as installing a dry pipe system or heating the area would be prohibitively expensive switch and a drain valve installed on each floor for ease of floor isolation. Associated

  4. DOE-STD-1066-99; Fire Protection Design Criteria

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:FinancingPetroleum Based| Department8, 2015 GATEWAY6.1viiiDepartment of4-9364-94 June 1994

  5. Calculation Methods for the Heat Release Rate of Materials of Unknown Composition 

    E-Print Network [OSTI]

    Biteau, Hubert; Steinhaus, Thomas; Simeoni, Albert; Schemel, Christopher; Marlair, Guy; Bal, Nicolas; Torero, Jose L

    The Heat Release Rate (HRR) is a critical parameter to characterise a fire. Different methods have been developed to estimate it. The most widespread techniques are based on mass balance. If the heat of combustion of the ...

  6. Electrical modeling of semiconductor bridge (SCB) BNCP detonators with electrochemical capacitor firing sets

    SciTech Connect (OSTI)

    Marx, K.D.; Ingersoll, D.; Bickes, R.W. Jr.

    1998-11-01

    In this paper the authors describe computer models that simulate the electrical characteristics and hence, the firing characteristics and performance of a semiconductor bridge (SCB) detonator for the initiation of BNCP [tetraammine-cis-bis (5-nitro-2H-tetrazolato-N{sup 2}) cobalt(III) perchlorate]. The electrical data and resultant models provide new insights into the fundamental behavior of SCB detonators, particularly with respect to the initiation mechanism and the interaction of the explosive powder with the SCB. One model developed, the Thermal Feedback Model, considers the total energy budget for the system, including the time evolution of the energy delivered to the powder by the electrical circuit, as well as that released by the ignition and subsequent chemical reaction of the powder. The authors also present data obtained using a new low-voltage firing set which employed an advanced electrochemical capacitor having a nominal capacitance of 350,000 {micro}F at 9 V, the maximum voltage rating for this particular device. A model for this firing set and detonator was developed by making measurements of the intrinsic capacitance and equivalent series resistance (ESR < 10 m{Omega}) of a single device. This model was then used to predict the behavior of BNCP SCB detonators fired alone, as well as in a multishot, parallel-string configuration using a firing set composed of either a single 9 V electrochemical capacitor or two of the capacitors wired in series and charged to 18 V.

  7. Development and testing of commercial-scale, coal-fired combustion systems: Phase 3

    SciTech Connect (OSTI)

    Not Available

    1992-01-01

    The US Department of Energy's Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and also indicated favorable economics for replacement of oil- and gas-fired equipment.

  8. Development and testing of commercial-scale, coal-fired combustion systems: Phase 3

    SciTech Connect (OSTI)

    Not Available

    1991-01-01

    The US Department of Energy's Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and also indicated favorable economics for replacement of oil- and gas-fired equipment.

  9. Development and testing of commercial-scale, coal-fired combustion systems

    SciTech Connect (OSTI)

    Not Available

    1991-01-01

    The US Department of Energy's Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and also indicated favorable economics for replacement of oil- and gas-fired equipment.

  10. Development and testing of commercial-scale, coal-fired combustion systems, Phase 3

    SciTech Connect (OSTI)

    Not Available

    1991-01-01

    The US Department of Energy's Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and also indicated favorable economics for replacement of oil- and gas-fired equipment.

  11. Development and testing of commercial-scale, coal-fired combustion systems, Phase 3

    SciTech Connect (OSTI)

    Not Available

    1990-01-01

    The US Department of Energy's Pittsburgh Energy Technology Center (PETC) is actively pursuing the development and testing of coal-fired combustion systems for residential, commercial, and industrial market sectors. In response, MTCI initiated the development of a new combustor technology based on the principle of pulse combustion under the sponsorship of PETC (Contract No. AC22-83PC60419). The initial pulse combustor development program was conducted in three phases (MTCI, Development of a Pulsed Coal Combustor Fired with CWM, Phase III Final Report, DOE Contract No. AC22-83PC60419, November 1986). Phase I included a review of the prior art in the area of pulse combustion and the development of pulse combustor design concepts. It led to the conclusion that pulse combustors offer technical and base-of-operation advantages over conventional burners and also indicated favorable economics for replacement of oil- and gas-fired equipment.

  12. Has fire suppression increased the amount of carbon stored in western U.S. forests?

    E-Print Network [OSTI]

    Fellows, Aaron W.; Goulden, Michael L.

    2008-01-01

    Davis. Chang, C. -R. (1996), Ecosystem responses to fire andvariations in fire regimes, Sierra Nevada Ecosystem Project:1990), Simulating cumulative fire effects in ponderosa pine/

  13. The Santa Ana Winds of Southern California in the context of Fire Weather

    E-Print Network [OSTI]

    Cao, Yang

    2015-01-01

    in the Los Angeles County Fire Department dataset betweenix Validation of Large Fire Potential (LFP)against observed fire activities between September 2008-

  14. Fire and Sudden Oak Death in Coast Redwood Forests: Effects of Two Distinct Disturbances

    E-Print Network [OSTI]

    Ramage, Benjamin Sean

    2011-01-01

    7. Keeley, J. E. 2005. Fire management impacts on invasiveecosystem productivity, and fire to climate change scenariosanalysis of natural fire rotation in the California redwood

  15. Global impact of smoke aerosols from landscape fires on climate and the Hadley circulation

    E-Print Network [OSTI]

    Tosca, M. G; Randerson, J. T; Zender, C. S

    2013-01-01

    on stand age in a boreal forest fire chronosequence, J.released from peat and forest fires in Indonesia duringevidence of smoke from forest fires inhibiting rainfall,

  16. Model comparisons for estimating carbon emissions from North American wildland fire

    E-Print Network [OSTI]

    2011-01-01

    emissions from Canadian forest fires, 1959–1999, Can. J.structure of the Canadian Forest Fire Behavior Predictionemissions from boreal forest fires, J. Geophys. Res. , 109,

  17. Introduction to Engineering Math and Physics through Fire Dynamics (Eight Lectures, bi-weekly)

    E-Print Network [OSTI]

    Shapiro, Benjamin

    properties) Ignition Phenomena Fire Spread Forest Fires Schedule Week 1 ­ Program intro, Understanding Temperature Calculations Week 7 ­ Final Assessment | Final project experiments/Labwork Week 8 ­ Forest Fires

  18. Fire dynamics during the 20th century simulated by the Community Land Model

    E-Print Network [OSTI]

    2010-01-01

    contemporary fire car- bon emissions to satellite-basedon the simulated fire car- bon emissions to explain thedeforestation) fire car- bon emissions were between 2.0 and

  19. Fire-related carbon emissions from land use transitions in southern Amazonia

    E-Print Network [OSTI]

    2008-01-01

    emissions from accidental forest fires, and forest damageof non-forest and pasture maintenance fires), and 3) high-of fires and biomass removal through combustion than forest

  20. FIRE DEPARTMENT, CITY OF NEW YORK * BUREAU OF FIRE PREVENTION CERTIFICATE OF FITNESS APPLICATION

    E-Print Network [OSTI]

    Jia, Songtao

    FIRE DEPARTMENT, CITY OF NEW YORK * BUREAU OF FIRE PREVENTION CERTIFICATE OF FITNESS APPLICATION Security # 846 29 120 MI ADDRESS 936 WEST END AVE APT E2 ZIP CODE 10025 STATE NY CITY OR BOROUGH New York RELATED EMPLOYER NAME COLUMBIA UNIVERSITY APPLICANT'S WORK ADDRESS CITY OR BOROUGH New York, NY STATE NY

  1. FireStream: Sensor Stream Processing for Monitoring Fire Spread Venkatesh Raghavan1

    E-Print Network [OSTI]

    locations required for spatial analysis, the Sen- sor Store, a collection of metadata pertinent to sensorsFireStream: Sensor Stream Processing for Monitoring Fire Spread Venkatesh Raghavan1 , ElkeStream, a sensor stream processing system which provides services for run-time de- tection, monitoring

  2. Fuel Treatment, Prescribed Fire, and Fire Restoration: Are the Benefits Worth It?

    E-Print Network [OSTI]

    Fuel Treatment, Prescribed Fire, and Fire Restoration: Are the Benefits Worth It? Chairs: Susan Husari and Melanie Miller #12;Applying Simulation and Optimization to Plan Fuel Treatments at Landscape Scales1 J. Greg Jones,2 Jimmie D. Chew,2 Hans R. Zuuring3 Abstract Fuel treatment activities are analyzed

  3. The Effects of Oxy-firing Conditions on Gas-phase Mercury Oxidation by Chlorine and Bromine

    SciTech Connect (OSTI)

    Buitrago, Paula; Silcox, Geoffrey

    2010-06-30

    Bench-scale experiments were conducted in a quartz-lined, natural gas-fired reactor with the combustion air replaced with a blend of 27 mole percent oxygen, with the balance carbon dioxide. Quench rates of 210 and 440 K/s were tested. In the absence of sulfur dioxide, the oxy-firing environment caused a remarkable increase in oxidation of mercury by chlorine. At 400 ppm chlorine (as HCl equivalent), air-firing results in roughly 5 percent oxidation. At the same conditions with oxy-firing, oxidation levels are roughly 80 percent. Oxidation levels with bromine at 25 and 50 ppm (as HBr equivalent) ranged from 80 to 95 percent and were roughly the same for oxy- and air-firing conditions. Kinetic calculations of levels of oxidation at air- and oxy-conditions captured the essential features of the experimental results but have not revealed a mechanistic basis for the oxidative benefits of oxy-firing conditions. Mixtures of 25 ppm bromine and 100 and 400 ppm chlorine gave more than 90 percent oxidation. At all conditions, the effects of quench rate were not significant. The presence of 500 ppm SO2 caused a dramatic decline in the levels of oxidation at all oxy-fired conditions examined. This effect suggests that SO2 may be preventing oxidation in the gas phase or preventing oxidation in the wetconditioning system that was used in quantifying oxidized and elemental mercury concentrations. Similar effects of SO2 have been noted with air-firing. The addition of sodium thiosulfate to the hydroxide impingers that are part of wet conditioning systems may prevent liquid-phase oxidation from occurring.

  4. NOx Control Options and Integration for US Coal Fired Boilers

    SciTech Connect (OSTI)

    Mike Bockelie; Marc Cremer; Kevin Davis; Martin Denison; Adel Sarofim; Connie Senior; Hong-Shig Shim; Dave Swenson; Bob Hurt; Eric Suuberg; Eric Eddings; Kevin Whitty; Larry Baxter; Calvin Bartholomew; William Hecker

    2006-06-30

    This is the Final Report for DOE Cooperative Agreement No: DE-FC26-00NT40753. The goal of the project was to develop cost-effective analysis tools and techniques for demonstrating and evaluating low-NOx control strategies and their possible impact on boiler performance for boilers firing US coals. The Electric Power Research Institute (EPRI) provided co-funding for this program. This project included research on: (1) In furnace NOx control; (2) Impacts of combustion modifications on boiler operation; (3) Selective Catalytic Reduction (SCR) catalyst testing and (4) Ammonia adsorption/removal on fly ash. Important accomplishments were achieved in all aspects of the project. Rich Reagent Injection (RRI), an in-furnace NOx reduction strategy based on injecting urea or anhydrous ammonia into fuel rich regions in the lower furnace, was evaluated for cyclone-barrel and PC fired utility boilers. Field tests successfully demonstrated the ability of the RRI process to significantly reduce NOx emissions from a staged cyclone-fired furnace operating with overfire air. The field tests also verified the accuracy of the Computational Fluid Dynamic (CFD) modeling used to develop the RRI design and highlighted the importance of using CFD modeling to properly locate and configure the reagent injectors within the furnace. Low NOx firing conditions can adversely impact boiler operation due to increased waterwall wastage (corrosion) and increased soot production. A corrosion monitoring system that uses electrochemical noise (ECN) corrosion probes to monitor, on a real-time basis, high temperature corrosion events within the boiler was evaluated. Field tests were successfully conducted at two plants. The Ohio Coal Development Office provided financial assistance to perform the field tests. To investigate soot behavior, an advanced model to predict soot production and destruction was implemented into an existing reacting CFD modeling tool. Comparisons between experimental data collected in a pilot scale furnace and soot behavior predicted by the CFD model showed good agreement. Field and laboratory tests were performed for SCR catalysts used for coal and biomass co-firing applications. Fundamental laboratory studies were performed to better understand mechanisms involved with catalyst deactivation. Field tests with a slip stream reactor were used to create catalyst exposed to boiler flue gas for firing coal and for co-firing coal and biomass. The field data suggests the mechanisms leading to catalyst deactivation are, in order of importance, channel plugging, surface fouling, pore plugging and poisoning. Investigations were performed to better understand the mechanisms involved with catalyst regeneration through mechanical or chemical methods. A computer model was developed to predict NOx reduction across the catalyst in a SCR. Experiments were performed to investigate the fundamentals of ammonia/fly ash interactions with relevance to the operation of advanced NOx control technologies such as selective catalytic reduction. Measurements were performed for ammonia adsorption isotherms on commercial fly ash samples subjected to a variety of treatments and on the chemistry of dry and semi-dry ammonia removal processes. This work resulted in the first fundamental ammonia isotherms on carbon-containing fly ash samples. This work confirms industrial reports that aqueous solution chemistry takes place upon the introduction of even very small amounts of water, while the ash remains in a semi-dry state.

  5. Assessment of simulation predictions of hydrocarbon pool fire tests.

    SciTech Connect (OSTI)

    Luketa-Hanlin, Anay Josephine

    2010-04-01

    An uncertainty quantification (UQ) analysis is performed on the fuel regression rate model within SIERRA/Fuego by comparing to a series of hydrocarbon tests performed in the Thermal Test Complex. The fuels used for comparison for the fuel regression rate model include methanol, ethanol, JP8, and heptane. The recently implemented flamelet combustion model is also assessed with a limited comparison to data involving measurements of temperature and relative mole fractions within a 2-m diameter methanol pool fire. The comparison of the current fuel regression rate model to data without UQ indicates that the model over predicts the fuel regression rate by 65% for methanol, 63% for ethanol, 95% for JP8, and 15% for heptane. If a UQ analysis is performed incorporating a range of values for transmittance, reflectance, and heat flux at the surface the current model predicts fuel regression rates within 50% of measured values. An alternative model which uses specific heats at inlet and boiling temperatures respectively and does not approximate the sensible heat is also compared to data. The alternative model with UQ significantly improves the comparison to within 25% for all fuels except heptane. Even though the proposed alternative model provides better agreement to data, particularly for JP8 and ethanol (within 15%), there are still outstanding issues regarding significant uncertainties which include heat flux gauge measurement and placement, boiling at the fuel surface, large scale convective motion within the liquid, and semi-transparent behavior.

  6. MSHA (Mine Safety and Health Administration) approved mine rescue - training module (coal): fires, fire fighting, and explosions. Mine rescue team series

    SciTech Connect (OSTI)

    Not Available

    1984-01-01

    Mine rescue teams frequently must fight fires and guard against the propagation of fires or explosions during a rescue and recovery operation. The team's ability to fight fires depends a great deal on hands-on experience with different fire fighting agents and equipment. The team's work includes an assessment of fire conditions, mine fire gases and other potential hazards associated with fire fighting activity. This training module covers the underlying principles of the fire triangle and the different methods for controlling, containing and extinguishing fires in a mine. The manual also covers fire-fighting equipment, considerations involved in a sealing operation and the cause-effect of explosions.

  7. 105-DR Large Sodium Fire Facility closure plan. Revision 1

    SciTech Connect (OSTI)

    Not Available

    1993-05-01

    The Hanford Site, located northwest of the city of Richland, Washington, houses reactors, chemical-separation systems, and related facilities used for the production of special nuclear materials, and activities associated with nuclear energy development. The 105-DR Large Sodium Fire Facility (LSFF), which was in operation from about 1972 to 1986, was a research laboratory that occupied the former ventilation supply room on the southwest side of the 105-DR Reactor facility. The LSFF was established to provide a means of investigating fire and safety aspects associated with large sodium or other metal alkali fires in the liquid metal fast breeder reactor (LMFBR) facilities. The 105-DR Reactor facility was designed and built in the 1950`s and is located in the 100-D Area of the Hanford Site. The building housed the 105-DR defense reactor, which was shut down in 1964. The LSFF was initially used only for engineering-scale alkali metal reaction studies. In addition, the Fusion Safety Support Studies program sponsored intermediate-size safety reaction tests in the LSFF with lithium and lithium lead compounds. The facility has also been used to store and treat alkali metal waste, therefore the LSFF is subject to the regulatory requirements for the storage and treatment of dangerous waste. Closure will be conducted pursuant to the requirements of the Washington Administrative Code (WAC) 173-303-610. This closure plan presents a description of the facility, the history of waste managed, and the procedures that will be followed to close the LSFF as an Alkali Metal Treatment Facility. No future use of the LSFF is expected.

  8. Characterization of Oxy-combustion Impacts in Existing Coal-fired Boilers

    SciTech Connect (OSTI)

    Adams, Bradley; Davis, Kevin; Senior, Constance; Shim, Hong Shim; Otten, Brydger; Fry, Andrew; Wendt, Jost; Eddings, Eric; Paschedag, Alan; Shaddix, Christopher; Cox, William; Tree, Dale

    2013-09-30

    Reaction Engineering International (REI) managed a team of experts from University of Utah, Siemens Energy, Praxair, Vattenfall AB, Sandia National Laboratories, Brigham Young University (BYU) and Corrosion Management Ltd. to perform multi-scale experiments, coupled with mechanism development, process modeling and CFD modeling, for both applied and fundamental investigations. The primary objective of this program was to acquire data and develop tools to characterize and predict impacts of CO{sub 2} flue gas recycle and burner feed design on flame characteristics (burnout, NO{sub x}, SO{sub x}, mercury and fine particle emissions, heat transfer) and operational concerns (fouling, slagging and corrosion) inherent in the retrofit of existing coal-fired boilers for oxy-coal combustion. Experimental work was conducted at Sandia National Laboratories’ Entrained Flow Reactor, the University of Utah Industrial Combustion Research Facility, and Brigham Young University. Process modeling and computational fluid dynamics (CFD) modeling was performed at REI. Successful completion of the project objectives resulted in the following key deliverables: 1) Multi-scale test data from 0.1 kW bench-scale, 100 kW and 200 kW laboratory-scale, and 1 MW semi-industrial scale combustors that describe differences in flame characteristics, fouling, slagging and corrosion for coal combustion under air-firing and oxygen-firing conditions, including sensitivity to oxy-burner design and flue gas recycle composition. 2) Validated mechanisms developed from test data that describe fouling, slagging, waterwall corrosion, heat transfer, char burnout and sooting under coal oxy-combustion conditions. The mechanisms were presented in a form suitable for inclusion in CFD models or process models. 3) Principles to guide design of pilot-scale and full-scale coal oxy-firing systems and flue gas recycle configurations, such that boiler operational impacts from oxy-combustion retrofits are minimized. 4) Assessment of oxy-combustion impacts in two full-scale coal-fired utility boiler retrofits based on computational fluid dynamics (CFD) modeling of air-fired and oxygen-fired operation. This research determined that it is technically feasible to retrofit the combustion system in an air-fired boiler for oxy-fired operation. The impacts of CO{sub 2} flue gas recycle and burner design on flame characteristics (burnout, NO{sub x}, SO{sub x}, mercury and fine particle emissions, heat transfer) and operational concerns (fouling, slagging and corrosion) were minimal, with the exception of high sulfur levels resulting from untreated flue gas recycle with medium and high-sulfur coals. This work focused on combustion in the radiant and convective sections of the boiler and did not address boiler system integration issues, plant efficiencies, impacts on downstream air pollution control devices, or CO{sub 2} capture and compression. The experimental data, oxy-firing system principles and oxy-combustion process mechanisms provided by this work can be used by electric utilities, boiler OEMs, equipment suppliers, design firms, software vendors, consultants and government agencies to assess retrofit applications of oxy-combustion technologies to existing boilers and to guide development of new designs.

  9. The Risk Imposed by Fire to Buildings and How to Address It 

    E-Print Network [OSTI]

    Torero, Jose L

    The history of fire science originates in the desire to enhance destruction of infrastructure by means of fire. Many of the basic principles of fire growth and the behaviour of structures in fire were developed within the ...

  10. GASIFICATION BASED BIOMASS CO-FIRING

    SciTech Connect (OSTI)

    Babul Patel; Kevin McQuigg; Robert Toerne; John Bick

    2003-01-01

    Biomass gasification offers a practical way to use this widespread fuel source for co-firing traditional large utility boilers. The gasification process converts biomass into a low Btu producer gas that can be used as a supplemental fuel in an existing utility boiler. This strategy of co-firing is compatible with a variety of conventional boilers including natural gas and oil fired boilers, pulverized coal fired conventional and cyclone boilers. Gasification has the potential to address all problems associated with the other types of co-firing with minimum modifications to the existing boiler systems. Gasification can also utilize biomass sources that have been previously unsuitable due to size or processing requirements, facilitating a wider selection of biomass as fuel and providing opportunity in reduction of carbon dioxide emissions to the atmosphere through the commercialization of this technology. This study evaluated two plants: Wester Kentucky Energy Corporation's (WKE's) Reid Plant and TXU Energy's Monticello Plant for technical and economical feasibility. These plants were selected for their proximity to large supply of poultry litter in the area. The Reid plant is located in Henderson County in southwest Kentucky, with a large poultry processing facility nearby. Within a fifty-mile radius of the Reid plant, there are large-scale poultry farms that generate over 75,000 tons/year of poultry litter. The local poultry farmers are actively seeking environmentally more benign alternatives to the current use of the litter as landfill or as a farm spread as fertilizer. The Monticello plant is located in Titus County, TX near the town of Pittsburgh, TX, where again a large poultry processor and poultry farmers in the area generate over 110,000 tons/year of poultry litter. Disposal of this litter in the area is also a concern. This project offers a model opportunity to demonstrate the feasibility of biomass co-firing and at the same time eliminate poultry litter disposal problems for the area's poultry farmers.

  11. Inflatable partition for fighting mine fires

    DOE Patents [OSTI]

    Conti, Ronald S. (Pittsburgh, PA); Lazzara, Charles P. (Pittsburgh, PA)

    1995-01-01

    The seal is a lightweight, inflatable, bag which may be inflated by a portable air generator and is used to seal a burning mine passage. A collapsible tube-like aperture extends through the seal and allows passage of high expansion foam through the seal in a feed tube. The foam fills the passageway and extinguishes the fire. In other embodiments, the feed tubes incorporate means to prevent collapse of the aperture. In these embodiments a shroud connects the feed tube to a foam generator. This seal allows creation of a high expansion foam fire fighting barrier even in upward sloping passages.

  12. Firing of pulverized solvent refined coal

    DOE Patents [OSTI]

    Lennon, Dennis R. (Allentown, PA); Snedden, Richard B. (McKeesport, PA); Foster, Edward P. (Macungie, PA); Bellas, George T. (Library, PA)

    1990-05-15

    A burner for the firing of pulverized solvent refined coal is constructed and operated such that the solvent refined coal can be fired successfully without any performance limitations and without the coking of the solvent refined coal on the burner components. The burner is provided with a tangential inlet of primary air and pulverized fuel, a vaned diffusion swirler for the mixture of primary air and fuel, a center water-cooled conical diffuser shielding the incoming fuel from the heat radiation from the flame and deflecting the primary air and fuel steam into the secondary air, and a watercooled annulus located between the primary air and secondary air flows.

  13. Fire Protection System Account Request Form | Department of Energy

    Broader source: Energy.gov (indexed) [DOE]

    December 2, 2010 Account request form used to obtain user credentials for the Fire Protection Database To obtain a user id and password to access the Fire Protection system, please...

  14. The FIRE infrared spectrometer at Magellan: construction and commissioning

    E-Print Network [OSTI]

    Simcoe, Robert A.

    We describe the construction and commissioning of FIRE, a new 0.8-2.5?m echelle spectrometer for the Magellan/ Baade 6.5 meter telescope. FIRE delivers continuous spectra over its full bandpass with nominal spectral ...

  15. A wildland fire modeling and visualization environment , Jonathan D. Beezley

    E-Print Network [OSTI]

    Utah, University of

    : · The wildland fire simulation code SFIRE coupled with a mesoscale atmospheric simulation code, the Weather by the coupling of a mesoscale weather model with a simple 2D fire spread model (Clark et al. 1996a,b, 2004; Coen

  16. PRESSURIZATION OF FIXED ROOF STORAGE TANKS DUE TO EXTERNAL FIRES

    E-Print Network [OSTI]

    Paris-Sud XI, Université de

    PRESSURIZATION OF FIXED ROOF STORAGE TANKS DUE TO EXTERNAL FIRES Fabien FouiHen, INERIS, Parc initiating event of the fire ball observed. In concrete terms, when a fixed roof storage tank is surrounded

  17. Modelling of the Growth Phase of Dalmarnock Fire Test One 

    E-Print Network [OSTI]

    Rein, Guillermo; Jahn, Wolfram; Torero, Jose L

    The challenge of modelling a well characterized full-scale fire test using computational fluid dynamics is illustrated in this work comparing a priori and a posteriori simulations. In 2006, The Dalmarnock Fire Tests were ...

  18. Factories: The Factories (Fire Certificate Application) Order, 1960 

    E-Print Network [OSTI]

    Hare, John

    1960-01-01

    This Order prescribes the form of application to the fire authority for a certificate under section 34 of the Factories Act, 1937, that premises are provided with such means of escape in case of fire for the persons ...

  19. An Interactive Planning Architecture \\Lambda The Forest Fire Fighting case

    E-Print Network [OSTI]

    Ricci, Francesco

    An Interactive Planning Architecture \\Lambda The Forest Fire Fighting case Anna Perini Support System aimed at supporting the user in the whole process of fire fighting including both situation

  20. Independent Oversight Review of the Fire Protection Program at...

    Office of Environmental Management (EM)

    pump and one diesel-driven fire pump attached to a new fire loop that surrounds the RPL. Pump controllers automatically maintain pressure in the underground loop to no less than...

  1. Fire Alarm Control Panel is located in Switchgear

    E-Print Network [OSTI]

    KEY: NORTH CHDD-South Floor 1 Fire Alarm Control Panel is located in Switchgear Room #CD11A Panel is located in Switchgear Room #CD11A on Basement Level Evacuation Route Exit Restroom Fire

  2. Management of Imported Fire Ants in Cattle Production Systems 

    E-Print Network [OSTI]

    Fuchs, Thomas W.; Drees, Bastiaan M.

    2004-03-31

    This publication can help ranch managers develop integrated pest management plans for managing fire ant problems in cattle operations. It covers the specifics of managing fire ants in hay pastures and rangelands, around farm ponds, and near...

  3. Oil-Fired Boilers and Furnaces | Department of Energy

    Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

    Oil-Fired Boilers and Furnaces Oil-Fired Boilers and Furnaces May 16, 2013 - 3:15pm Addthis Diagram of an oil boiler. New tanks are generally double-wall or have a spill container...

  4. CLIMATE-FIRE RELATIONSHIPS IN THE SOUTHERN APPALACHIAN MOUNTAINS 

    E-Print Network [OSTI]

    Baker, Ralph C.

    2011-01-11

    This study is meant to explain the fire regime of the southern Appalachian Mountain Range of the southeastern United States by analyzing spatial statistics and climate-fire relationships. The spatial statistics were created by obtaining...

  5. GREENHOUSE GAS EMISSIONS CONTROL BY OXYGEN FIRING IN CIRCULATING FLUIDIZED BED BOILERS

    SciTech Connect (OSTI)

    Nsakala ya Nsakala; Gregory N. Liljedahl

    2003-05-15

    Given that fossil fuel fired power plants are among the largest and most concentrated producers of CO{sub 2} emissions, recovery and sequestration of CO{sub 2} from the flue gas of such plants has been identified as one of the primary means for reducing anthropogenic CO{sub 2} emissions. In this study, ALSTOM Power Inc. (ALSTOM) has investigated several coal fired power plant configurations designed to capture CO{sub 2} from effluent gas streams for use or sequestration. Burning fossil fuels in mixtures of oxygen and recirculated flue gas (made principally of CO{sub 2}) essentially eliminates the presence of atmospheric nitrogen in the flue gas. The resulting flue gas is comprised primarily of CO{sub 2}. Oxygen firing in utility scale Pulverized Coal (PC) fired boilers has been shown to be a more economical method for CO{sub 2} capture than amine scrubbing (Bozzuto, et al., 2001). Additionally, oxygen firing in Circulating Fluid Bed Boilers (CFB's) can be more economical than in PC or Stoker firing, because recirculated gas flow can be reduced significantly. Oxygen-fired PC and Stoker units require large quantities of recirculated flue gas to maintain acceptable furnace temperatures. Oxygen-fired CFB units, on the other hand, can accomplish this by additional cooling of recirculated solids. The reduced recirculated gas flow with CFB units results in significant Boiler Island cost savings. Additionally, ALSTOM has identified several advanced/novel plant configurations, which improve the efficiency and cost of the CO{sub 2} product cleanup and compression process. These advanced/novel concepts require long development efforts. An economic analysis indicates that the proposed oxygen-firing technology in circulating fluidized boilers could be developed and deployed economically in the near future in enhanced oil recovery (EOR) applications or enhanced gas recovery (EGR), such as coal bed methane recovery. ALSTOM received a Cooperative Agreement from the US Department of Energy National Energy Technology Laboratory (DOE) in 2001 to carry out a project entitled ''Greenhouse Gas Emissions Control by Oxygen Firing in Circulating Fluidized Bed Boilers.'' This two-phased project is in effect from September 28, 2001, to October 27, 2004. (U.S. DOE NETL Cooperative Agreement No. DE-FC26-01NT41146). Phase I consisted of an evaluation of the technical feasibility and economics of alternate CO{sub 2} capture technologies applied to Greenfield US coal-fired electric generation power plants, and supporting bench-scale testing. And Phase II consists of pilot-scale testing, supporting a refined performance and economic evaluation of the oxygen-fired AFC concept. Phase I, detailed in this report, entails a comprehensive study evaluating the technical feasibility and economics of alternate CO{sub 2} capture technologies applied to Greenfield US coal-fired electric generation power plants. Thirteen separate but related cases (listed below), representing various levels of technology development, were evaluated as described herein. The first seven cases represent coal combustion cases in CFB type equipment. The next four cases represent Integrated Gasification Combined Cycle (IGCC) systems. The last two cases represent advanced Chemical Looping systems, which were completely paid for by ALSTOM and included herein for completeness.

  6. Enhanced Elemental Mercury Removal from Coal-fired Flue Gas by Sulfur-chlorine Compounds

    E-Print Network [OSTI]

    Miller, Nai-Qiang Yan-Zan Qu Yao Chi Shao-Hua Qiao Ray Dod Shih-Ger Chang Charles

    2008-01-01

    Coal-fired power generating plants contribute approximatelynumber of coal-fired generating plants (1-3). The mercury is

  7. Tree Mortality following Prescribed Fire and a Storm Surge Event in Slash Pine ( Pinus elliottii var. densa ) Forests in the Florida Keys, USA

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Sah, Jay P.; Ross, Michael S.; Snyder, James R.; Ogurcak, Danielle E.

    2010-01-01

    In fire-dependent forests, managers are interested in predicting the consequences of prescribed burning on postfire tree mortality. We examined the effects of prescribed fire on tree mortality in Florida Keys pine forests, using a factorial design with understory type, season, and year of burn as factors. We also used logistic regression to model the effects of burn season, fire severity, and tree dimensions on individual tree mortality. Despite limited statistical power due to problems in carrying out the full suite of planned experimental burns, associations with tree and fire variables were observed. Post-fire pine tree mortality was negatively correlated withmore »tree size and positively correlated with char height and percent crown scorch. Unlike post-fire mortality, tree mortality associated with storm surge from Hurricane Wilma was greater in the large size classes. Due to their influence on population structure and fuel dynamics, the size-selective mortality patterns following fire and storm surge have practical importance for using fire as a management tool in Florida Keys pinelands in the future, particularly when the threats to their continued existence from tropical storms and sea level rise are expected to increase.« less

  8. Tree Mortality following Prescribed Fire and a Storm Surge Event in Slash Pine (Pinus elliottiivar.densa) Forests in the Florida Keys, USA

    DOE Public Access Gateway for Energy & Science Beta (PAGES Beta)

    Sah, Jay P.; Ross, Michael S.; Snyder, James R.; Ogurcak, Danielle E.

    2010-01-01

    In fire-dependent forests, managers are interested in predicting the consequences of prescribed burning on postfire tree mortality. We examined the effects of prescribed fire on tree mortality in Florida Keys pine forests, using a factorial design with understory type, season, and year of burn as factors. We also used logistic regression to model the effects of burn season, fire severity, and tree dimensions on individual tree mortality. Despite limited statistical power due to problems in carrying out the full suite of planned experimental burns, associations with tree and fire variables were observed. Post-fire pine tree mortality was negatively correlated withmore »tree size and positively correlated with char height and percent crown scorch. Unlike post-fire mortality, tree mortality associated with storm surge from Hurricane Wilma was greater in the large size classes. Due to their influence on population structure and fuel dynamics, the size-selective mortality patterns following fire and storm surge have practical importance for using fire as a management tool in Florida Keys pinelands in the future, particularly when the threats to their continued existence from tropical storms and sea level rise are expected to increase.« less

  9. Fire hazards evaluation for light duty utility arm system

    SciTech Connect (OSTI)

    HUCKFELDT, R.A.

    1999-02-24

    In accordance with DOE Order 5480.7A, Fire Protection, a Fire Hazards Analysis must be performed for all new facilities. LMHC Fire Protection has reviewed and approved the significant documentation leading up to the LDUA operation. This includes, but is not limited to, development criteria and drawings, Engineering Task Plan, Quality Assurance Program Plan, and Safety Program Plan. LMHC has provided an appropriate level of fire protection for this activity as documented.

  10. Modeling the effects of fire severity and climate warming on active layer thickness and soil carbon storage of black spruce forests across the landscape in interior Alaska

    SciTech Connect (OSTI)

    Genet, Helene [Institute of Arctic Biology (IAB), University of Alaska, Fairbanks (UAF)] [Institute of Arctic Biology (IAB), University of Alaska, Fairbanks (UAF); McGuire, A. David [University of Alaska] [University of Alaska; Barrett, K. [USGS Alaska Science Center] [USGS Alaska Science Center; Breen, Amy [International Arctic Research Center, SNAP, University of Alaska, Fairbanks (UAF)] [International Arctic Research Center, SNAP, University of Alaska, Fairbanks (UAF); Euskirchen, Eugenie S [University of Alaska] [University of Alaska; Johnstone, J. F. [University of Saskatchewan] [University of Saskatchewan; Kasischke, Eric S. [University of Maryland, College Park] [University of Maryland, College Park; Melvin, A. M. [University of Florida, Gainesville] [University of Florida, Gainesville; Bennett, A. [International Arctic Research Center, SNAP, University of Alaska, Fairbanks (UAF)] [International Arctic Research Center, SNAP, University of Alaska, Fairbanks (UAF); Mack, M. C. [University of Florida, Gainesville] [University of Florida, Gainesville; Rupp, Scott T. [International Arctic Research Center, SNAP, University of Alaska, Fairbanks (UAF)] [International Arctic Research Center, SNAP, University of Alaska, Fairbanks (UAF); Schuur, Edward [University of Florida] [University of Florida; Turetsky, M. R. [University of Guelph, Canada] [University of Guelph, Canada; Yuan, Fengming [ORNL] [ORNL

    2013-01-01

    There is a substantial amount of carbon stored in the permafrost soils of boreal forest ecosystems, where it is currently protected from decomposition. The surface organic horizons insulate the deeper soil from variations in atmospheric temperature. The removal of these insulating horizons through consumption by fire increases the vulnerability of permafrost to thaw, and the carbon stored in permafrost to decomposition. In this study we ask how warming and fire regime may influence spatial and temporal changes in active layer and carbon dynamics across a boreal forest landscape in interior Alaska. To address this question, we (1) developed and tested a predictive model of the effect of fire severity on soil organic horizons that depends on landscape-level conditions and (2) used this model to evaluate the long-term consequences of warming and changes in fire regime on active layer and soil carbon dynamics of black spruce forests across interior Alaska. The predictive model of fire severity, designed from the analysis of field observations, reproduces the effect of local topography (landform category, the slope angle and aspect and flow accumulation), weather conditions (drought index, soil moisture) and fire characteristics (day of year and size of the fire) on the reduction of the organic layercaused by fire. The integration of the fire severity model into an ecosystem process-based model allowed us to document the relative importance and interactions among local topography, fire regime and climate warming on active layer and soil carbon dynamics. Lowlands were more resistant to severe fires and climate warming, showing smaller increases in active layer thickness and soil carbon loss compared to drier flat uplands and slopes. In simulations that included the effects of both warming and fire at the regional scale, fire was primarily responsible for a reduction in organic layer thickness of 0.06 m on average by 2100 that led to an increase in active layer thickness of 1.1 m on average by 2100. The combination of warming and fire led to a simulated cumulative loss of 9.6 kgC m 2 on average by 2100. Our analysis suggests that ecosystem carbon storage in boreal forests in interior Alaska is particularly vulnerable, primarily due to the combustion of organic layer thickness in fire and the related increase in active layer thickness that exposes previously protected permafrost soil carbon to decomposition.

  11. WILDLAND FIRE SERVICES CENTER FOR ENVIRONMENTAL MANAGEMENT OF MILITARY LANDS

    E-Print Network [OSTI]

    products and services to assist military land managers and range operations personnel in protecting against is already in place. Fire Management Planning CEMML provides high quality fire management planning adviceWILDLAND FIRE SERVICES CENTER FOR ENVIRONMENTAL MANAGEMENT OF MILITARY LANDS CEMML | 1490 Campus

  12. Fire Safety Challenges of Tall Wood Final Report

    E-Print Network [OSTI]

    Fire Safety Challenges of Tall Wood Buildings Final Report Prepared by: Robert Gerard and David Barber Arup North America Ltd San Francisco, CA Armin Wolski San Francisco, CA © December 2013 Fire Protection Research Foundation THE FIRE PROTECTION RESEARCH FOUNDATION ONE BATTERYMARCH PARK QUINCY

  13. FIRE Action Plan to Respond to Next Step Options

    E-Print Network [OSTI]

    1 FIRE Action Plan to Respond to Next Step Options Program Advisory Committee Report #2 July 3, 2001 The FIRE Action s are listed among the NSO-PAC2 recommendations. 1. Response to NSO PAC-1 Report Representatives of the FIRE project presented an action plan for how to respond to issues that had been raised

  14. Building Fire Emergency Detection and Response Using Wireless Sensor Networks

    E-Print Network [OSTI]

    Sreenan, Cormac J.

    1 Building Fire Emergency Detection and Response Using Wireless Sensor Networks Yuanyuan Zeng, Seán technologies. Fire emergency detection and response for building environments is a novel application area for this problem. Then we describe work on the use of WSNs to improve fire evacuation and navigation. Keywords

  15. WRF-Fire Applied in Bulgaria Nina Dobrinkova1

    E-Print Network [OSTI]

    Borissova, Daniela

    WRF-Fire Applied in Bulgaria Nina Dobrinkova1 Georgi Jordanov2 Jan Mandel3 1 Institute and Statistical Sciences University of Colorado Denver jan.mandel@ucdenver.edu Abstract. WRF-Fire consists of the WRF (Weather Research and Forecasting Model) coupled with a fire spread model, based on the level- set

  16. FIRE Actions in Response to Next Step Options

    E-Print Network [OSTI]

    FIRE Actions in Response to Next Step Options Program Advisory Committee Report NSO-PAC CHARGES #1. The present level of effort in physics analysis is not fully adequate for ongoing high priority FIRE studies a strong focused effort on the FIRE physics and engineering studies. High priority must also be given

  17. ENGINEERING STATUS OF THE FUSION IGNITION RESEARCH EXPERIMENT (FIRE)

    E-Print Network [OSTI]

    ENGINEERING STATUS OF THE FUSION IGNITION RESEARCH EXPERIMENT (FIRE) Philip J. Heitzenroeder Dale 08543 Cambridge, MA 02139 (609)-243-3043 (609)-243-3301 (617)-253-8155 For the FIRE Project Team ABSTRACT FIRE is a compact, high field tokamak being studied as an option for the next step in the US

  18. Structural stability of polymer matrix composite panels in fire

    E-Print Network [OSTI]

    Dao, Ming

    Structural stability of polymer matrix composite panels in fire Pei Gu a,*, Ming Dao b , R.J. Asaro Structural integrity in fire a b s t r a c t Development in advanced composite fabrication technology offers by fire. This paper addresses the compressive load-bearing capacity for polymer matrix composite panels

  19. FIRE Optimization Activities J. Schultz, J. Schmidt and D. Meade

    E-Print Network [OSTI]

    FIRE Optimization Activities J. Schultz, J. Schmidt and D. Meade Presented to NSO-PAC2 Meeting MIT-PSFC, Cambridge, MA January 17, 2001 FIRE Lighting the Way to Fusion Response to NSO-PAC1 #12;NSO-PAC Recommendations on FIRE Optimization Finding F1-3: The Committee also endorses the project's focus

  20. Forest Fire Spread and Suppression in DEVS Lewis Ntaimo1

    E-Print Network [OSTI]

    Forest Fire Spread and Suppression in DEVS Lewis Ntaimo1 , Bithika Khargharia2 , Bernard P. Zeigler2 , Maria J. Vasconcelos3 Abstract In this paper we discuss modeling and simulation of forest fire simulation-based predictions of forest fire spread and suppression in uniform and non-uniform environmental

  1. Seeing Red: New Tools for Mapping and Understanding Fire Severity

    E-Print Network [OSTI]

    1 Seeing Red: New Tools for Mapping and Understanding Fire Severity The 2012 fire season was resource managers tools to assess severity before, during, and after a wildfire. FIRESEV has produced a suite of tools for a wide range of fire management applications, including real-time forecasts

  2. Carbon dioxide emission during forest fires ignited by lightning

    E-Print Network [OSTI]

    Pelc, Magdalena

    2009-01-01

    In this paper we developed the model for the carbon dioxide emission from forest fire. The master equation for the spreading of the carbon dioxide to atmosphere is the hyperbolic diffusion equation. In the paper we study forest fire ignited by lightning. In that case the fores fire has the well defined front which propagates with finite velocity.

  3. Carbon dioxide emission during forest fires ignited by lightning

    E-Print Network [OSTI]

    Magdalena Pelc; Radoslaw Osuch

    2009-03-31

    In this paper we developed the model for the carbon dioxide emission from forest fire. The master equation for the spreading of the carbon dioxide to atmosphere is the hyperbolic diffusion equation. In the paper we study forest fire ignited by lightning. In that case the fores fire has the well defined front which propagates with finite velocity.

  4. Guidance for the Quality Assurance of Fire Protection Systems

    Broader source: Energy.gov [DOE]

    This quality assurance document is intended to provide guidance for the DOE fire protection community in the continuing effort to ensure the reliability of fire protection systems. This guidance document applies the concepts of DOE Order 5700.6C, Quality Assurance, to the management of fire protection systems.

  5. Forest fires, explosions, and random trees Edward Crane

    E-Print Network [OSTI]

    Wirosoetisno, Djoko

    Forest fires, explosions, and random trees Edward Crane HIMR, UoB 13th January 2014 #12 and James Martin at the University of Oxford. Edward Crane (HIMR, UoB) Forest fires, explosions, and random trees 13th January 2014 2 / 20 #12;Overview This talk is about the mean field forest fire model

  6. Prediction of Forest Fires using Data Mining Methods

    E-Print Network [OSTI]

    McLeod, Ian

    Prediction of Forest Fires using Data Mining Methods By Hye Rin Kim Supervised by Dr. McLeod Master's Project July 2009 #12;Contents 1 Executive Summary 2 2 Introduction 2 2.1 Forest Fire Data . . . . . . . . . . . . . . . . . . . . . 11 5 Conclusion 13 6 References 14 1 #12;1 Executive Summary Forest fires are a major environmental

  7. What should employers do to protect workers from fire hazards?

    E-Print Network [OSTI]

    Johnson, Eric E.

    . Address evacuation of employees who stay behind to shut down critical plant equipment. Include preferred fire hazards in the workplace and about what to do in a fire emergency. If you want your workers require for emergency fire exits? Every workplace must have enough exits suitably located to enable

  8. Levels and Sources of Forest Fire Prevention Knowledge

    E-Print Network [OSTI]

    Standiford, Richard B.

    Levels and Sources of Forest Fire Prevention Knowledge of California Hunters William S. Folkman U;Folkman, William S. 1963. Levels and sources of forest fire prevention knowl- edge of California hunters-managerial occupations. Their level of knowl- edge about forest fire prevention is generally high, but their knowledge

  9. The Impact of Boreal Forest Fire on Climate Warming

    E-Print Network [OSTI]

    Zender, Charles

    The Impact of Boreal Forest Fire on Climate Warming J. T. Randerson,1 * H. Liu,2 M. G. Flanner,1 S measurements and analysis of a boreal forest fire, integrating the effects of greenhouse gases, aerosols, black the concept of radiative forcing (12) to assess quantitatively the net effect of a boreal forest fire

  10. Forest Management Helps Save Chadron State Park from Fire

    E-Print Network [OSTI]

    Farritor, Shane

    Forest Management Helps Save Chadron State Park from Fire OVER THE PAST HALF-CENTURY, wildfire has Creek Fire on its deadly rampage across the Pine Ridge. The good news is that due to active forest no infrastructure and its forest survived the fire intact. About 90 percent of the Park burned, with the majority

  11. APPLICATIONS Forest Fire Spread and Suppression in DEVS

    E-Print Network [OSTI]

    Ntaimo, Lewis

    APPLICATIONS Forest Fire Spread and Suppression in DEVS Lewis Ntaimo Department of Industrial. Speedway Tucson, AZ 85721 In this article, the authors discuss modeling and simulation of forest fire to obtain timely simulation-based predictions of forest fire spread and suppression in uniform

  12. Appendix 30 Fire Effects on Key Ecological Processes in Forested

    E-Print Network [OSTI]

    Appendix 30 Fire Effects on Key Ecological Processes in Forested Ecosystems The following paragraphs on fire effects on forest succession are from Stickney (1982) Forest Succession ...the severity of the pre-disturbance forest herb species also demonstrated the ability to survive fire, particularly those

  13. Retrofitted coal-fired firetube boiler and method employed therewith

    DOE Patents [OSTI]

    Wagoner, Charles L. (Tullahoma, TN); Foote, John P. (Tullahoma, TN)

    1995-01-01

    A coal-fired firetube boiler and a method for converting a gas-fired firetube boiler to a coal-fired firetube boiler, the converted boiler including a plurality of combustion zones within the firetube and controlled stoichiometry within the combustion zones.

  14. Retrofitted coal-fired firetube boiler and method employed therewith

    DOE Patents [OSTI]

    Wagoner, C.L.; Foote, J.P.

    1995-07-04

    A coal-fired firetube boiler and a method for converting a gas-fired firetube boiler to a coal-fired firetube boiler are disclosed. The converted boiler includes a plurality of combustion zones within the firetube and controlled stoichiometry within the combustion zones. 19 figs.

  15. Coal-fired generation staging a comeback. 2nd ed.

    SciTech Connect (OSTI)

    NONE

    2007-07-01

    The report is an overview of the renewed U.S. market interest in coal-fired power generation. It provides a concise look at what is driving interest in coal-fired generation, the challenges faced in implementing coal-fired generation projects, and the current and future state of coal-fired generation. Topics covered in the report include: An overview of coal-fired generation including its history, the current market environment, and its future prospects; An analysis of the key business factors that are driving renewed interest in coal-fired generation; An analysis of the challenges that are hindering the implementation of coal-fired generation projects; A description of coal-fired generation technologies; A review of the economic drivers of coal-fired generation project success; An evaluation of coal-fired generation versus other generation technologies; A discussion of the key government initiatives supporting new coal-fired generation; and A listing of planned coal-fired generation projects. 13 figs., 12 tabs., 1 app.

  16. The Application of a Genetic Algorithm to Estimate Material Properties for Fire Modeling from Bench-Scale Fire Test Data 

    E-Print Network [OSTI]

    Lautenberger, Chris; Rein, Guillermo; Fernandez-Pello, Carlos

    A methodology based on an automated optimization technique that uses a genetic algorithm (GA) is developed to estimate the material properties needed for CFD-based fire growth modeling from bench-scale fire test data. ...

  17. A Risk-based Optimization Modeling Framework for Mitigating Fire Events for Water and Fire Response Infrastructures 

    E-Print Network [OSTI]

    Kanta, Lufthansa Rahman

    2011-02-22

    ) minimizing the cost of mitigation. Third, a stochastic modeling approach is developed to assess urban fire risk for the coupled water distribution and fire response systems that includes probabilistic expressions for building ignition, WDS failure, and wind...

  18. The Safety of Sports Grounds (Designation) Order 1992 

    E-Print Network [OSTI]

    Her Majesty's Stationary Office

    1992-03-13

    Article 2 of this Order designates the Sports grounds specified therein as sports grounds requiring safety certificate under the Safety of Sports Ground Act 1975. That Act was amended by Schedule 2 to the Fire Safety and ...

  19. Pollutant emissions from portable kerosene-fired space heaters

    SciTech Connect (OSTI)

    Traynor, G.W.; Allen, J.R.; Apte, M.G.; Girman, J.R.; Hollowell, C.D.

    1983-06-01

    Indoor use of unvented combustion appliances is known to cause an increase in indoor air pollutants. We conducted laboratory tests on two radiant and two convective portable kerosene-fired space heaters to identify the pollutants they emit and to determine their emission rates. Results show that carbon dioxide, carbon monoxide, nitric oxide, nitrogen dioxide, and formaldehyde were emitted by both types of heaters and that the radiant heaters and one of the convective heaters also emitted trace amounts of fine particles. When such heaters are operated for 1 h in a 27-m/sup 3/ chamber with 0.4 air changes per hour, the resultant CO/sub 2/ concentrations are well above the U.S. occupational standard, and NO/sub 2/ concentrations are well above California's short-term outdoor standard.

  20. Effect of oxy-firing on fireside corrosion

    SciTech Connect (OSTI)

    Bestor, Michael A [ORNL; Pint, Bruce A [ORNL

    2011-01-01

    Using oxygen, rather than air, in coal-fired boilers has been studied for several years as a strategy to reduce NO{sub x} and concentrate CO{sub 2} for capture. In combination with flue gas recirculation, higher levels of CO{sub 2}, H{sub 2}O and likely SO{sub 2} are expected. In order to understand the role of substrate composition on corrosion, a combination of commercial and model alloys are being investigated both with and without the presence of synthetic coal ash. The current project is focusing on ferritic steels but rates will be compared with austenitic steels, Ni-base alloys, and potential coating compositions.

  1. FireGrid: Integrated emergency response and fire safety engineering for the future built environment 

    E-Print Network [OSTI]

    Berry, Dave; Usmani, Asif; Torero, Jose L; Tate, Austin; McLaughlin, Stephen; Potter, Stephen; Trew, Arthur; Baxter, Rob; Bull, Mark; Atkinson, Malcolm

    2005-09-20

    Analyses of disasters such as the Piper Alpha explosion (Sylvester-Evans and Drysdale, 1998), the World Trade Centre collapse (Torero et al, 2002 , Usmani et al, 2003) and the fires at Kings Cross (Drysdale et al, 1992) ...

  2. FireGrid: Integrated emergency response and fire safety engineering for the future built environment 

    E-Print Network [OSTI]

    Berry, Dave; Usmani, Asif; Torero, Jose L; Tate, Austin; McLaughlin, Stephen; Potter, Stephen; Trew, Arthur; Baxter, Rob; Bull, Mark; Atkinson, Malcolm

    FireGrid is researching the development and integration of modelling, sensors, Grid, HPC, and C/C technologies. It will stimulate further research, in new safety systems and strategies, in new sensor technologies, in ...

  3. Dynamics of fire plumes and smoke clouds associated with peat and deforestation fires in Indonesia

    E-Print Network [OSTI]

    Tosca, M. G; Randerson, J. T; Zender, C. S; Nelson, D. L; Diner, D. J; Logan, J. A

    2011-01-01

    biomass burning in Indonesia since 1960, Nat. Geosci. , 2,and deforestation fires in Indonesia M. G. Tosca, 1 J. T.unnatural disasters in Indonesia, Geogr. Rev. , 94, 55–79,

  4. The radiological impact of the 2000 Hanford Fire (24-Command Fire

    E-Print Network [OSTI]

    Henderson, Ashley David

    2001-01-01

    into more populated areas. This paper examines the radiological impact of the 24-Command Fire, which occurred on the Hanford Site in late June 2000. Several different approaches are compared against each other to determine the validity of the results...

  5. The Piloted Transition to Flaming in Smoldering Fire Retarded and Non-Fire Retarded Polyurethane Foam 

    E-Print Network [OSTI]

    Putzeys, Olivier; Fernandez-Pello, Carlos; Rein, Guillermo; Urban, David

    The piloted transition from smoldering to flaming, though a significant fire safety concern, has not been previously extensively studied. Experimental results are presented on the piloted transition from smoldering to ...

  6. Wildland Fire Management Plan for Brookhaven National Laboratory

    SciTech Connect (OSTI)

    Green,T.

    2009-10-23

    This Wildland Fire Management Plan (FMP) for Brookhaven National Lab (BNL) updates the 2003 plan incorporating changes necessary to comply with DOE Order 450.1 and DOE P 450.4, Federal Wildland Fire Management Policy and Program Review; Wildland and Prescribed Fire Management Policy and implementation Procedures Reference Guide. This current plan incorporates changes since the original draft of the FMP that result from new policies on the national level. This update also removes references and dependence on the U.S. Fish & Wildlife Service and Department of the Interior, fully transitioning Wildland Fire Management responsibilities to BNL. The Department of Energy policy for managing wildland fires requires that all areas, managed by the DOE and/or its various contractors, that can sustain fire must have a FMP that details fire management guidelines for operational procedures associated with wild fire, operational, and prescribed fires. Fire management plans provide guidance on fire preparedness, fire prevention, wildfire suppression, and the use of controlled, 'prescribed' fires and mechanical means to control the amount of available combustible material. Values reflected in the BNL Wildland FMP include protecting life and public safety; Lab properties, structures and improvements; cultural and historical sites; neighboring private and public properties; and endangered, threatened, and species of concern. Other values supported by the plan include the enhancement of fire-dependent ecosystems at BNL. This FMP will be reviewed periodically to ensure the fire program advances and evolves with the missions of the DOE and BNL. This Fire Management Plan is presented in a format that coverers all aspects specified by DOE guidance documents which are based on the national template for fire management plans adopted under the National Fire Plan. The DOE is one of the signatory agencies on the National Fire Plan. This FMP is to be used and implemented for the entire BNL site including the Upton Reserve and has been reviewed by, The Nature Conservancy, New York State Department of Environmental Conservation Forest Rangers, and DOE, as well as appropriate BNL emergency services personnel. The BNL Fire Department is the lead on wildfire suppression. However, the BNL Natural Resource Manager will be assigned to all wildland fires as technical resource advisor.

  7. Bioenergetics: budgeting the fires of life

    E-Print Network [OSTI]

    Limburg, Karin E.

    1 Bioenergetics: budgeting the fires of life K. Limburg lecture notes Fisheries Science Reading: Adams, S.M., and J.E. Breck. 1990. Bioenergetics. In C.B. Schreck and P.B. Moyle, editors. Methods is bioenergetics? The study of the processing of energy by living systems, at any level of biological organization

  8. DOE Fire Protection Handbook, Volume I

    SciTech Connect (OSTI)

    1996-08-01

    The Department of Energy (DOE) Fire Protection Program is delineated in a number of source documents including; the Code of Federal Regulations (CFR), DOE Policy Statements and Orders, DOE and national consensus standards (such as those promulgated by the National Fire Protection Association), and supplementary guidance, This Handbook is intended to bring together in one location as much of this material as possible to facilitate understanding and ease of use. The applicability of any of these directives to individual Maintenance and Operating Contractors or to given facilities and operations is governed by existing contracts. Questions regarding applicability should be directed to the DOE Authority Having Jurisdiction for fire safety. The information provided within includes copies of those DOE directives that are directly applicable to the implementation of a comprehensive fire protection program. They are delineated in the Table of Contents. The items marked with an asterisk (*) are included on the disks in WordPerfect 5.1 format, with the filename noted below. The items marked with double asterisks are provided as hard copies as well as on the disk. For those using MAC disks, the files are in Wordperfect 2.1 for MAC.

  9. Risk Assessment of Diesel-Fired

    E-Print Network [OSTI]

    Mlllet, Dylan B.

    Risk Assessment of Diesel-Fired Back-up Electric Generators Operating in California Prepared of the toxicity of various hazardous air pollutants in diesel emissions. Wayne Miller, the Director discussions on diesel back-up generators and, more broadly, the environmental health impacts of electricity

  10. 2015 Winter and Spring Fire Potential Assessment

    E-Print Network [OSTI]

    2015 Winter and Spring Fire Potential Assessment For the Grass Dominant Fuels on the Western Plains Factors · Fine Fuel Conditions · Drought · Seasonal Temperature and Precipitation #12;Grass Dominant Fuels Grass dominant fuels are generally found west of the red line shown on the map. During the dormant

  11. Blank fire configuration for automatic pistol

    DOE Patents [OSTI]

    Teague, Tommy L. (Albuquerque, NM)

    1990-01-01

    A pistol configured to fire blank cartridges includes a modified barrel with a breech portion connected to an aligned inner sleeve. Around the inner sleeve, there is disposed an outer sleeve having a vent therein through which the cartridge discharges. The breech portion is connected to a barrel anchor to move backward in a slight arc when the pistol is fired. A spring retention rod projects from the barrel anchor and receives a shortened recoil spring therearound which recoil spring has one end abutting a stop on the barrel anchor and the other end in abutment with the end of a spring retaining cup. The spring retaining cup is engaged by a flange projecting from a slide so that when the pistol is fired, the slide moves rearwardly against the compression of the spring to eject the spent cartridge and then moves forwardly under the urging of the spring to load a fresh cartridge into the breech portion. The spring then returns all of the slidable elements to their initial position so that the pistol may again be fired.

  12. Fired heater for coal liquefaction process

    DOE Patents [OSTI]

    Ying, David H. S. (Macungie, PA)

    1984-01-01

    A fired heater for a coal liquefaction process is constructed with a heat transfer tube having U-bends at regular intervals along the length thereof to increase the slug frequency of the multi-phase mixture flowing therethrough to thereby improve the heat transfer efficiency.

  13. Fluorescence Assay for Polymerase Arrival Rates

    E-Print Network [OSTI]

    Che, Austin

    2003-08-31

    To engineer complex synthetic biological systems will require modular design, assembly, and characterization strategies. The RNA polymerase arrival rate (PAR) is defined to be the rate that RNA polymerases arrive at a ...

  14. Fluorescence assay for polymerase arrival rates

    E-Print Network [OSTI]

    Che, Austin, 1979-

    2004-01-01

    To engineer complex synthetic biological systems will require modular design, assembly, and characterization strategies. The RNA polymerase arrival rate (PAR) is defined to be the rate that RNA polymerases arrive at a ...

  15. Home Energy Ratings and Building Performance 

    E-Print Network [OSTI]

    Gardner, J.C.

    2008-01-01

    climate as they affect the rating score of a proposed or completed structure. The rating is used to determine the most cost effective mechanical systems, building envelope design including window and door types, effect of various roofing materials...

  16. FireWxNet: A Multi-Tiered Portable Wireless System for Monitoring Weather Conditions in Wildland Fire

    E-Print Network [OSTI]

    Han, Richard Y.

    FireWxNet: A Multi-Tiered Portable Wireless System for Monitoring Weather Conditions in Wildland Fire Environments Carl Hartung, Richard Han Department of Computer Science University of Colorado In this paper we present FireWxNet, a multi-tiered portable wireless system for monitoring weather conditions

  17. Modeling long-term fire regimes of southern California shrublands1 (Suggested running head: "Modeling fire regimes with HFire")3

    E-Print Network [OSTI]

    Carlson, Jean

    1 Modeling long-term fire regimes of southern California shrublands1 2 (Suggested running head: "Modeling fire regimes with HFire")3 4 Seth H. Petersona , Max A. Moritzb , Marco E. Moraisc , Philip E for Fire Research & Outreach, Department of Environmental Science, Policy, & Management,10 UC Berkeley, CA

  18. Modeling of a coal-fired natural circulation boiler

    SciTech Connect (OSTI)

    Bhambare, K.S.; Mitra, S.K.; Gaitonde, U.N.

    2007-06-15

    Modeling of a natural circulation boiler for a coal-fired thermal power station is presented here. The boiler system is divided into seven subcomponents, and for each section, models based on conservation of mass, momentum, and energy are formulated. The pressure drop at various sections and the heat transfer coefficients are computed using empirical correlations. Solutions are obtained by using SIMULINK. The model is validated by comparing its steady state and dynamic responses with the actual plant data. Open loop responses of the model to the step changes in the operating parameters, such as pressure, temperature, steam flow, feed water flow, are also analyzed. The present model can be used for the development and design of effective boiler control systems.

  19. 2015 American Geophysical Union. All rights reserved. Remote sensing constraints on South America fire traits by Bayesian fusion

    E-Print Network [OSTI]

    emissions. The reduction in combusted biomass density is consistent with a reduction (4-6%) in GOME-2 solar in combustion characteristics in 2010 relative to 2007. We find an 88% probability in reduced combusted biomass fire carbon losses were likely low due to reduced biomass combustion rates Index terms: 0365

  20. Is the situation and immediate threat to life and health? Spill/Leak/Release Medical Emergency Fire or Flammable Gas Spill/Leak/Release Medical Emergency Fire or Flammable Gas Chemical Odor? Possible Fire / Natural Gas

    E-Print Network [OSTI]

    ? Possible Fire / Natural Gas (including chemicals and bio agents") (not including chemicals or bio agents Fire or Flammable Gas Spill/Leak/Release Medical Emergency Fire or Flammable Gas Chemical Odor