Powered by Deep Web Technologies
Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

SEISMIC DESIGN EVALUATION GUIDELINES FOR BURIED PIPING FOR THE DOE HLW FACILITIES'  

Office of Scientific and Technical Information (OSTI)

6 1 6 1 7 1 1 SEISMIC DESIGN EVALUATION GUIDELINES FOR BURIED PIPING FOR THE DOE HLW FACILITIES' Chi-Wen Lin Consultant, Martinez, CA George Antaki Westinghouse Savannah River Co., Aiken, SC Kamal Bandyopadhyay Brookhaven National Lab., Upton, NY ABSTRACT This paper presents the seismic design and evaluation guidelines for underground piping for the Department of Energy (DOE) High-Level-Waste (HLW) Facilities. The underground piping includes both single and double containment steel pipes and concrete pipes with steel lining, with particular emphasis on the double containment piping. The design and evaluation guidelines presented in this paper follow the generally accepted beam-on-elastic- foundation analysis principle and the inertial response calculation method, respectively, for piping directly

2

Design and evaluation guidelines for Department of Energy facilities subjected to natural phenomena hazards  

Science Conference Proceedings (OSTI)

The Department of Energy (DOE) and the DOE Natural Phenomena Hazards Panel have developed uniform design and evaluation guidelines for protection against natural phenomena hazards at DOE sites throughout the United States. The goal of the guidelines is to assure that DOE facilities can withstand the effects of natural phenomena such as earthquakes, extreme winds, tornadoes, and flooding. The guidelines apply to both new facilities (design) and existing facilities (evaluation, modification, and upgrading). The intended audience is primarily the civil/structural or mechanical engineers conducting the design or evaluation of DOE facilities. The likelihood of occurrence of natural phenomena hazards at each DOE site has been evaluated by the DOE Natural Phenomena Hazard Program. Probabilistic hazard models are available for earthquake, extreme wind/tornado, and flood. Alternatively, site organizations are encouraged to develop site-specific hazard models utilizing the most recent information and techniques available. In this document, performance goals and natural hazard levels are expressed in probabilistic terms, and design and evaluation procedures are presented in deterministic terms. Design/evaluation procedures conform closely to common standard practices so that the procedures will be easily understood by most engineers. Performance goals are expressed in terms of structure or equipment damage to the extent that: (1) the facility cannot function; (2) the facility would need to be replaced; or (3) personnel are endangered. 82 refs., 12 figs., 18 tabs.

Kennedy, R.P. (Structural Mechanics Consulting, Inc., Yorba Linda, CA (USA)); Short, S.A. (ABB Impell Corp., Mission Viejo, CA (USA)); McDonald, J.R. (Texas Tech Univ., Lubbock, TX (USA)); McCann, M.W. Jr. (Benjamin (J.R.) and Associates, Inc., Mountain View, CA (USA)); Murray, R.C. (Lawrence Livermore National Lab., CA (USA)); Hill, J.R. (USDOE Assistant Secretary for Environment, Safety, and He

1990-06-01T23:59:59.000Z

3

Seismic design evaluation guidelines for buried piping for the DOE HLW Facilities  

SciTech Connect

This paper presents the seismic design and evaluation guidelines for underground piping for the Department of Energy (DOE) High-Level-Waste (HLW) Facilities. The underground piping includes both single and double containment steel pipes and concrete pipes with steel lining, with particular emphasis on the double containment piping. The design and evaluation guidelines presented in this paper follow the generally accepted beam-on-elastic-foundation analysis principle and the inertial response calculation method, respectively, for piping directly in contact with the soil or contained in a jacket. A standard analysis procedure is described along with the discussion of factors deemed to be significant for the design of the underground piping. The following key considerations are addressed: the design feature and safety requirements for the inner (core) pipe and the outer pipe; the effect of soil strain and wave passage; assimilation of the necessary seismic and soil data; inertial response calculation for the inner pipe; determination of support anchor movement loads; combination of design loads; and code comparison. Specifications and justifications of the key parameters used, stress components to be calculated and the allowable stress and strain limits for code evaluation are presented.

Lin, Chi-Wen [Consultant, Martinez, CA (United States); Antaki, G. [Westinghouse Savannah River Co., Aiken, SC (United States); Bandyopadhyay, K. [Brookhaven National Lab., Upton, NY (United States); Bush, S.H. [Review & Synthesis Association, Richland, WA (United States); Costantino, C. [City Univ. of New York, New York, NY (United States); Kennedy, R. [RPK Structural Mechanics, Yorba Linda, CA (United States). Consultant

1995-05-01T23:59:59.000Z

4

Guidelines for conceptual design and evaluation of aquifer thermal energy storage  

DOE Green Energy (OSTI)

Guidelines are presented for use as a tool by those considering application of a new technology, aquifer thermal energy storage (ATES). The guidelines will assist utilities, municipalities, industries, and other entities in the conceptual design and evaluation of systems employing ATES. The potential benefits of ATES are described, an overview is presented of the technology and its applications, and rules of thumb are provided for quickly judging whether a proposed project has sufficient promise to warrant detailed conceptual design and evaluation. The characteristics of sources and end uses of heat and chill which are seasonally mismatched and may benefit from ATES (industrial waste heat, cogeneration, solar heat, and winter chill, for space heating and air conditioning) are discussed. Storage and transport subsystems and their expected performance and cost are described. A 10-step methodology is presented for conceptual design of an ATES system and evaluation of its technical and economic feasibility in terms of energy conservation, cost savings, fuel substitution, improved dependability of supply, and abatement of pollution, with examples, and the methodology is applied to a hypothetical proposed ATES system, to illustrate its use.

Meyer, C.F.; Hauz, W.

1980-10-01T23:59:59.000Z

5

Implementation of seismic design and evaluation guidelines for the Department of Energy high-level waste storage tanks and appurtenances  

SciTech Connect

In the fall of 1992, a draft of the Seismic Design and Evaluation Guidelines for the Department of Energy (DOE) High-level Waste Storage Tanks and Appurtenances was issued. The guidelines were prepared by the Tanks Seismic Experts Panel (TSEP) and this task was sponsored by DOE, Environmental Management. The TSEP is comprised of a number of consultants known for their knowledge of seismic ground motion and expertise in the analysis of structures, systems and components subjected to seismic loads. The development of these guidelines was managed by staff from Brookhaven National Laboratory, Engineering Research and Applications Division, Department of Nuclear Energy. This paper describes the process used to incorporate the Seismic Design and Evaluation Guidelines for the DOE High-Level Waste Storage Tanks and Appurtenances into the design criteria for the Multi-Function Waste Tank Project at the Hanford Site. This project will design and construct six new high-level waste tanks in the 200 Areas at the Hanford Site. This paper also discusses the vehicles used to ensure compliance to these guidelines throughout Title 1 and Title 2 design phases of the project as well as the strategy used to ensure consistent and cost-effective application of the guidelines by the structural analysts. The paper includes lessons learned and provides recommendations for other tank design projects which might employ the TSEP guidelines.

Conrads, T.J.

1993-06-01T23:59:59.000Z

6

DESIGN GUIDELINE SUMMARY  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Rev. 3 3 Rev. 3 August 2003 Rev. June 2004 Design Guideline Summary Based on the GEOVISION Report of Stanford Linear Accelerator Tunnel Vibration Measurements Parsons Pasadena, CA For Stanford Linear Accelerator Center Stanford University Stanford, CA Abstract: This summary report is provided in order to suggest how the measurement data from the GEOVision report might be used by SLAC for their proposed Next Linear Collider facility. See the referenced report "Stanford Linear Accelerator Tunnel Vibration Measurements, Conducted at MTA Universal Subway Station, North Hollywood, California", by GEOVision dated July 28, 2003. The following discussions are an attempt to determine an upper bound methodology that can be used for design purposes. The data in the

7

FDH radiological design review guidelines  

SciTech Connect

These guidelines discuss in more detail the radiological design review process used by the Project Hanford Management Contractors as described in HNF-PRO-1622, Radiological Design Review Process. They are intended to supplement the procedure by providing background information on the design review process and providing a ready source of information to design reviewers. The guidelines are not intended to contain all the information in the procedure, but at points, in order to maintain continuity, they contain some of the same information.

Millsap, W.J.

1998-09-29T23:59:59.000Z

8

Seismic design and evaluation guidelines for the Department of Energy High-Level Waste Storage Tanks and Appurtenances  

Science Conference Proceedings (OSTI)

This document provides seismic design and evaluation guidelines for underground high-level waste storage tanks. The guidelines reflect the knowledge acquired in the last two decades in defining seismic ground motion and calculating hydrodynamic loads, dynamic soil pressures and other loads for underground tank structures, piping and equipment. The application of the guidelines is illustrated with examples. The guidelines are developed for a specific design of underground storage tanks, namely double-shell structures. However, the methodology discussed is applicable for other types of tank structures as well. The application of these and of suitably adjusted versions of these concepts to other structural types will be addressed in a future version of this document. The original version of this document was published in January 1993. Since then, additional studies have been performed in several areas and the results are included in this revision. Comments received from the users are also addressed. Fundamental concepts supporting the basic seismic criteria contained in the original version have since then been incorporated and published in DOE-STD-1020-94 and its technical basis documents. This information has been deleted in the current revision.

Bandyopadhyay, K.; Cornell, A.; Costantino, C.; Kennedy, R.; Miller, C.; Veletsos, A.

1995-10-01T23:59:59.000Z

9

Seismic design and evaluation guidelines for the Department of Energy high-level waste storage tanks and appurtenances  

Science Conference Proceedings (OSTI)

This document provides guidelines for the design and evaluation of underground high-level waste storage tanks due to seismic loads. Attempts were made to reflect the knowledge acquired in the last two decades in the areas of defining the ground motion and calculating hydrodynamic loads and dynamic soil pressures for underground tank structures. The application of the analysis approach is illustrated with an example. The guidelines are developed for specific design of underground storage tanks, namely double-shell structures. However, the methodology discussed is applicable for other types of tank structures as well. The application of these and of suitably adjusted versions of these concepts to other structural types will be addressed in a future version of this document.

Bandyopadhyay, K.; Cornell, A.; Costantino, C.; Kennedy, R.; Miller, C.; Veletsos, A.

1993-01-01T23:59:59.000Z

10

K-Basins design guidelines  

Science Conference Proceedings (OSTI)

The purpose of the design guidelines is to enable SNF and K Basin personnel to complete fuel and sludge removal, and basin water mitigation by providing engineering guidance for equipment design for the fuel basin, facility modifications (upgrades), remote tools, and new processes. It is not intended to be a purchase order reference for vendors. The document identifies materials, methods, and components that work at K Basins; it also Provides design input and a technical review process to facilitate project interfaces with operations in K Basins. This document is intended to compliment other engineering documentation used at K Basins and throughout the Spent Nuclear Fuel Project. Significant provisions, which are incorporated, include portions of the following: General Design Criteria (DOE 1989), Standard Engineering Practices (WHC-CM-6-1), Engineering Practices Guidelines (WHC 1994b), Hanford Plant Standards (DOE-RL 1989), Safety Analysis Manual (WHC-CM-4-46), and Radiological Design Guide (WHC 1994f). Documents (requirements) essential to the engineering design projects at K Basins are referenced in the guidelines.

Roe, N.R.; Mills, W.C.

1995-06-01T23:59:59.000Z

11

User Experience Design Guidelines for Windows Phone  

E-Print Network (OSTI)

User Experience Design Guidelines for Windows Phone The UI Design and Interaction Guide for Windows superseded by the User Experience Design Guidelines for Windows Phone on MSDN ® . There are six parts to the new guidelines: 1. The Windows Phone Platform: Takes a brief look at the types of applications

Narasayya, Vivek

12

Guidelines for the Monitoring, Evaluation, Reporting, Verification...  

NLE Websites -- All DOE Office Websites (Extended Search)

Evaluation, Reporting, Verification, and Certification of Forestry Projects for Climate Change Mitigation Title Guidelines for the Monitoring, Evaluation, Reporting,...

13

Human Engineering Design Guidelines for Maintainability  

Science Conference Proceedings (OSTI)

Utility managers, designers, and engineers can now systematically incorporate appropriate human factors engineering principles and criteria for maintainability into new plant designs or existing plant modifications. Using these guidelines can also result in increased productivity, safety, and plant availability.

1985-12-01T23:59:59.000Z

14

Evaluation of Occupational Magnetic Field Exposure Guidelines  

Science Conference Proceedings (OSTI)

As a first step in assessing potential effects of EMF exposure guidelines on utility operations, EPRI sponsored a technical evaluation of the major occupational EMF exposure guidelines and an analysis of existing magnetic-field exposure databases. The research reported herein is a comprehensive extension of that work, that includes studies by several research groups on diverse topics related to guidelines.

1998-12-15T23:59:59.000Z

15

Energy Design Guidelines for High Performance Schools: Hot and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Design Guidelines for High Performance Schools: Hot and Humid Climates Energy Design Guidelines for High Performance Schools: Hot and Humid Climates School districts around...

16

City of San Jose- Solar Access Design Guidelines  

Energy.gov (U.S. Department of Energy (DOE))

The San Jose Environmental Services Department has developed voluntary guidelines to encourage solar orientation in new construction. These Solar Access Design Guidelines specify that the long...

17

Building design guidelines for solar energy technologies  

DOE Green Energy (OSTI)

There are two main objectives to this publication. The first is to find out the communalities in the experience gained in previous studies and in actual applications of solar technologies in buildings, residential as well as nonresidential. The second objective is to review innovative concepts and products which may have an impact on future developments and applications of solar technologies in buildings. The available information and common lessons were collated and presented in a form which, hopefully, is useful for architects and solar engineers, as well as for teachers of solar architecture'' and students in Architectural Schools. The publication is based mainly on the collection and analysis of relevant information. The information included previous studies in which the performance of solar buildings was evaluated, as well as the personal experience of the Author and the research consultants. The state of the art, as indicated by these studies and personal experience, was summarized and has served as basis for the development of the Design Guidelines. In addition to the summary of the state of the art, as was already applied in solar buildings, an account was given of innovative concepts and products. Such innovations have occurred in the areas of thermal storage by Phase Change Materials (PCM) and in glazing with specialized or changeable properties. Interesting concepts were also developed for light transfer, which may enable to transfer sunlight to the core areas of large multi story nonresidential buildings. These innovations may have a significant impact on future developments of solar technologies and their applications in buildings. 15 refs., 19 figs., 3 tabs.

Givoni, B.

1989-01-01T23:59:59.000Z

18

Energy Design Guidelines for High Performance Schools: Tropical Island Climates  

SciTech Connect

The Energy Design Guidelines for High Performance Schools--Tropical Island Climates provides school boards, administrators, and design staff with guidance to help them make informed decisions about energy and environmental issues important to school systems and communities. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school in tropical island climates. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs.

Not Available

2004-11-01T23:59:59.000Z

19

Guideline for the Seismic Technical Evaluation of Replacement Items for Nuclear Power Plants  

Science Conference Proceedings (OSTI)

This guideline provides practical, cost-effective techniques for reasonably assuring that replacement items will meet seismic performance requirements. Meeting such requirements is necessary to maintain the seismic design basis of commercial nuclear power plants. The guideline also offers a method for determining when a seismic technical evaluation of replacement items is required as part of the procurement process for spare and replacement items.

1993-06-01T23:59:59.000Z

20

Advanced human-system interface design review guidelines  

SciTech Connect

Advanced, computer-based, human-system interface designs are emerging in nuclear power plant (NPP) control rooms. These developments may have significant implications for plant safety in that they will greatly affect the ways in which operators interact with systems. At present, however, the only guidance available to the US Nuclear Regulatory Commission (NRC) for the review of control room-operator interfaces, NUREG-0700, was written prior to these technological changes and is thus not designed to address them. The objective of the project reported in this paper is to develop an Advanced Control Room Design Review Guideline for use in performing human factors reviews of advanced operator interfaces. This guideline will be implemented, in part, as a portable, computer-based, interactive document for field use. The paper describes the overall guideline development methodology, the present status of the document, and the plans for further guideline testing and development. 21 refs., 3 figs.

O'Hara, J.M.

1990-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

for licensing technologies Savannah River Nuclear Solutions Savannah River National Laboratory We're pleased you've chosen to submit a request for a Savannah River Nuclear Solutions license. We look forward to helping you launch a new product. Our License Application comes in two parts. You may submit the Intent to License first, followed by the more detailed Business Plan. Or, you may submit both at the same time. These guidelines, which may or may not apply in all circumstances, describe the information we need to evaluate your request. Please take a moment to determine which of these guidelines apply to you. If you have any questions, please don't hesitate to call us. Cover page Please provide your company name, address, phone, fax, e-mail and Web site. Also include the name of a contact

22

Design guidelines for downtown shopping centers  

E-Print Network (OSTI)

This thesis focuses on urban design issues germane to downtown shopping center design. The underlying concept is that, all new downtown shopping centers should attempt to build upon the existing fabric in such a way as to ...

McGhee, Billy Kevin

1987-01-01T23:59:59.000Z

23

Design guidelines for web applications based on local patterns  

Science Conference Proceedings (OSTI)

We present the results of a project to determine web design guidelines bases on user interface design patterns present in Chilean web applications. The scope of the work is restricted to web applications in the .cl domain. We consider three types of ... Keywords: usability, user interfaces, web applications

César I. Llanos; Marcia N. Muñoz

2007-05-01T23:59:59.000Z

24

Design and Specification Guidelines for Large Draft Fans and Systems  

Science Conference Proceedings (OSTI)

Design shortcomings in draft fans and related air-gas systems can cause fan failure and costly outages of large fossil fuel power plants. These guidelines will help engineers and manufacturers achieve a better understanding of the design features needed to minimize such failures.

1983-12-01T23:59:59.000Z

25

Guidelines help design pneumatic control systems  

Science Conference Proceedings (OSTI)

The three areas of particular interest to the gas-transmission engineer about pneumatic-instrument-operated control valves are (1) the fail-position probability of a system, (2) the designated action required for each component in the pneumatic circuit, and (3) the schematically defined position of each component. Compared with self-operated control valves, the instrument-operated systems perform many more functions; they can control the flow and the volume or flow-volume combinations, with both pressure override and underride, and will adapt conveniently to remote operation. Schematic diagrams illustrate the numerous system designs possible for pressure-regulation, flow-control, and relief-valve duties.

Curry, R.N.

1981-01-26T23:59:59.000Z

26

University of Houston Campus Design Guidelines and Standards  

E-Print Network (OSTI)

for the campus; (3) and a Procurement and Delivery Procedures notebook for all facilities projects Procedures manual also apply to the "Architectural Design Guidelines". Other related University of Houston, and conditions that apply to the University of Houston System Procurement and Delivery Procedures also apply

Azevedo, Ricardo

27

Pumped Solar Domestic Hot Water (SDHW) system design guidelines  

SciTech Connect

This article provides practical guidelines based on experience gained from the design, installation, and commissioning of a pumped Solar Domestic Hot Water (SDHW) system in Saudi Arabia. The authors believe that such information is not readily available and will be useful to designers and installers of SDHW systems within the region. Since the current motivation for buying SDHW systems in Saudi Arabia is not strictly economic, it is imperative that a professional reference be available, against which the soundness of any technical decisions could be confirmed prior to their implementation. The intent is to ensure that systems designed and installed will operate reliably, therefore enhancing customer satisfaction.

Arshad, K.; Said, S.A.M. (King Fahd Univ. of Petroleum Minerals, Dhahran (Saudi Arabia))

1989-01-01T23:59:59.000Z

28

Advanced control room design review guidelines: Integration of the NUREG-0700 guidelines and development of new human-system interface guidelines  

Science Conference Proceedings (OSTI)

This report documents the work conducted in four tasks of the Nuclear Regulatory Commission (NRC) project entitled Review Criteria for Human Factors Aspects of Advanced Controls and Instrumentation. The purpose of the first task was to integrate the applicable sections of NUREG-0700 into the advanced control room design review (ACRDR) guidelines to ensure that all applicable guidelines are together in one document and conveniently accessible to users. The primary objective of the second task was to formulate a strategy for the development of new ACRDR guidelines that have not otherwise been identified. The main focus of the third task was to modify the individual ACRDR guidelines generated to date to ensure that they are suitable for the intended nuclear power plant (NPP) control station system application. The goal of the fourth task was to develop human factors guidelines for two human-system interface categories that are missing from the current ACRDR guidelines document. During the first task those areas in NUREG-0700 that are not addressed by the ACRDR guidelines document were identified, the areas were subsequently reviewed against six recent industry human factors engineering review guidelines, and the NUREG-0700 guidelines were updated as necessary. In the second task 13 general categories of human-system interface guidelines that are either missing from or not adequately addressed by the ACRDR document were discovered. An approach was derived for the development of new ACRDR guidelines, a preliminary assessment of the available sources that may be useful in the creation of new guidelines and their applicability to the identified human-system interface categories was performed, and an estimate was made of the amount of time and level of effort required to complete the development of needed new ACRDR guidelines. During the third task those NPP control station systems to which the NUREG-0700 and ACRDR guidelines apply were identified, matrices of such applicability were developed to support the needs of the NRC inspectors and reviewers, a guideline modification audit and tracking system was designed, and the ACRDR guidelines were reviewed and modified where appropriate to ensure that their language is applicable to the nuclear industry. In the fourth task control and input device guidelines were generated and human factors guidelines for specific nuclear operations were drafted.

Carter, R.J.

1997-07-01T23:59:59.000Z

29

Mechanical safety subcommittee guideline for design of thin windows for vacuum vessels  

SciTech Connect

This guideline specifies the usage of thin windows for vacuum vessels in terms of their design and application a Fermilab.

Western, J.L.

1993-03-01T23:59:59.000Z

30

Mechanical Safety Subcommittee guideline for design of thin windows for vacuum vessels  

SciTech Connect

This guideline specifies the usage of thin windows for vacuum vessels in terms of their design and application at Fermilab.

Western, J.L.

1991-03-06T23:59:59.000Z

31

Mechanical safety subcommittee guideline for design of thin windows for vacuum vessels. Revised  

SciTech Connect

This guideline specifies the usage of thin windows for vacuum vessels in terms of their design and application a Fermilab.

Western, J.L.

1993-03-01T23:59:59.000Z

32

Nuclear plant design and modification guidelines for PWR steam generator reliability  

Science Conference Proceedings (OSTI)

Operating experience gathered from PWR plant operation during the 1960's and 1970's has been incorporated into a series of design guidelines for secondary plant systems and steam generators. Specific guidelines included in this volume are: plant design for PWR steam generator inspection and nondestructive testing, revision 1; guidelines for design of steam generator blowdown systems, revision 1; plant design guidelines for layup and cleanup of steam, feedwater, and condensate systems, revision 1; design guidelines for plant secondary systems, revision 1 and plant design for steam generator replaceability, revision 1. The guidelines are intended to address those aspects of new plant design which will minimize corrosion damage to steam generators by controlling impurity ingress, facilitate steam generator nondestructive testing and provide for eventual replacement of steam generator if necessary. The guidelines, last revised in 1986, are primarily applicable to new plant construction, however, some of the guidelines may also be applicable to major backfits to existing plants.

Not Available

1991-09-01T23:59:59.000Z

33

Calcium spray dryer waste management: Design guidelines: Final report  

SciTech Connect

Calcium spray drying is a commercially available and applied technology used to control SO/sub 2/ emissions. This process is rapidly gaining utility acceptance. Because physical and chemical properties of wastes generated by calcium spray drying differ from those of conventional coal combustion by-products (fly ash and scrubber sludge) typical waste management practices may need to be altered. This report presents technical guidelines for designing and operating a calcium spray drying waste management system. Waste transfer, storage, pretreatment/conditioning, transport and disposal are addressed. The report briefly describes eighteen existing or planned calcium spray drying waste management systems. Results of waste property tests conducted as part of this study, and test data from other studies are reported and compared. Conceptual designs of both new and retrofit calcium spray drying waste management systems also are presented to demonstrate the economic impact of spray drying on waste management. Parametric cost sensitivity analyses illustrate the impact of significant design parameters on waste management costs. Existing calcium spray drying waste management experiences, as well as spray drying waste property data provided the basis for guideline development. Because existing calcium spray drying facilities burn low sulfur coal, this report is considered applicable only to calcium spray drying wastes produced from low sulfur coal. At this time, calcium spray drying is not expected to be feasible for high sulfur coal applications.

1987-09-01T23:59:59.000Z

34

Modular 5 MW geothermal power plant design considerations and guidelines  

DOE Green Energy (OSTI)

The design considerations and guideline documents given define the principal design requirements for a nominal 5 MW geothermal power plant of a type to permit over-the-road transport of its several modules. The power plant system defined is supplied with steam from a single flash steam separator stage, located at the plant area, and supplied with steam from two wells at nominal pressure of 3.8 Kg/cm/sup 2/ Abs (54 psia). In some cases where the content of noxious noncondensable gases is high, a shell and tube condenser would be substituted for the direct contact type condenser specified and an additional module containing an H/sub 2/S removal system would be added. Guidelines are given for the following: site preparation, collection system, plant installation, assembly, and test; turbine generator module; condenser and noncondensable gas removal module; plant control and switchgear module; cooling water circulation pump module; steam-water separator module; maintenance, office, and lavatory module; reinjection pump module; cooling tower modules; spray pond installation and piping; and auxiliary generator module. (MHR)

Not Available

1976-05-01T23:59:59.000Z

35

Equipment design guidelines for remote hot cell operations.  

SciTech Connect

Hot cells provide a unique and challenging environment for designing remotely operated equipment. A typical hot cell is an isolated room used to protect operators from highly contaminated and radioactive equipment. Hot cells usually have thick reinforced concrete walk and leaded glass windows. Operations within the hot cell are accomplished using master-slave manipulators and overhead crane or electro-mechanical manipulator systems. The inability to perform hands-on operation and maintenance in hot cells requires special design considerations. Some of these design considerations include operational interfaces, radiation, accessibility, replaceability/interchangeability, decontamination, atmospheric conditions, functionality, operator fatigue, and ease of use. This paper will discuss guidelines for designing hot cell remotely operated equipment that has been used successfully at Argonne National Laboratory. General topics in this paper will include master-slave manipulator types and limitations, overhead handling systems, viewing limitations, types and sizes of typical fasteners, hot cell compatible materials, mockup testing, guide features for mating parts, modularity, labeling, electrical fasteners, and lifting fixtures.

Wahlquist, D. R.

1998-07-10T23:59:59.000Z

36

March 23, 2008 DB:EER Model -1 1 Informal Design Guidelines  

E-Print Network (OSTI)

March 23, 2008 DB:EER Model - 1 1 Informal Design Guidelines #12;March 23, 2008 DB:EER Model - 1 2 Design Guidelines for Relational Schema + #12;March 23, 2008 DB:EER Model - 1 3 - Measuring the Quality, 2008 DB:EER Model - 1 4 - Database Design Methodology A Bottom-Up Method We start by identifying all

Adam, Salah

37

Center embossed diaphragm design guidelines and Fabry-Perot diaphragm fiber optic sensor  

Science Conference Proceedings (OSTI)

This research established the design guidelines for center embossed diaphragms for micro-diaphragm fiber type sensors. Following the guidelines, a center embossed diaphragm fiber optic sensor (CE-DFOS) based on Fabry-Perot interference was designed and ... Keywords: Acoustic sensor, Center embossed diaphragm, Fabry-Perot, Fiber optic, MEMS

Yan Sun; Ganhua Feng; George Georgiou; Edip Niver; Karen Noe; Ken Chin

2008-05-01T23:59:59.000Z

38

Towards landscape design guidelines for reducing Lyme disease risk  

E-Print Network (OSTI)

Background Incidence of Lyme disease in the US continues to grow. Low-density development is also increasing in endemic regions, raising questions about the relationship between development pattern and disease. This study sought to model Lyme disease incidence rate using quantitative, practical metrics of regional landscape pattern. The objective was to progress towards the development of design guidelines that may help minimize known threats to human and environmental health. Methods Ecological analysis was used to accommodate the integral landscape variables under study. Case data derived from passive surveillance reports across 12 counties in the US state of Maryland during 1996–2000; 2137 cases were spatially referenced to residential addresses. Major roads were used to delineate 514 landscape analysis units from 0.002 to 580 km 2. Results The parameter that explained the most variation in incidence rate was the percentage of land-cover edge represented by the adjacency of forest and herbaceous cover [R 2 5 0.75; rate ratio 5 1.34 (1.26–1.43); P, 0.0001]. Also highly significant was the percentage of the landscape in forest cover (cumulative R 2 5 0.82), which exhibited a quadratic relationship with incidence rate. Modelled relationships applied throughout the range of landscape sizes. Conclusions Results begin to provide quantitative landscape design parameters for reducing casual peridomestic contact with tick and host habitat. The final model suggests that clustered forest and herbaceous cover, as opposed to high forest-herbaceous interspersion, would minimize Lyme disease risk in low-density residential areas. Higher-density development that precludes a large percentage of forestherbaceous edge would also limit exposure.

Laura E Jackson; Elizabeth D Hilborn; James C Thomas

2005-01-01T23:59:59.000Z

39

Energy Design Guidelines for High Performance Schools: Arctic and Subarctic Climates  

Science Conference Proceedings (OSTI)

The Energy Design Guidelines for High Performance Schools--Arctic and Subarctic Climates provides school boards, administrators, and design staff with guidance to help them make informed decisions about energy and environmental issues important to school systems and communities. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school in arctic and subarctic climates. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs.

Not Available

2004-11-01T23:59:59.000Z

40

Nondestructive Evaluation: Indication Characterization, Evaluation, and Disposition Guideline  

Science Conference Proceedings (OSTI)

Operating experience of in-service inspections (ISIs) of nuclear power plants includes cases in which human error or inadequate implementation of examination plans resulted in issues with the application of qualified nondestructive evaluation (NDE) procedures. These issues can result in degraded NDE performance. The operating experience for the basis of the initial report centered principally on ultrasonic testing (UT) examination of dissimilar metal welds (DMWs) in reactor piping systems. The more ...

2012-10-31T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

City of San Jose - Solar Access Design Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

City of San Jose - Solar Access Design Guidelines City of San Jose - Solar Access Design Guidelines City of San Jose - Solar Access Design Guidelines < Back Eligibility Construction Residential Savings Category Heating & Cooling Commercial Heating & Cooling Solar Heating Buying & Making Electricity Water Heating Program Info State California Program Type Solar/Wind Access Policy Provider City of San Jose The San Jose Environmental Services Department has developed voluntary guidelines to encourage solar orientation in new construction. These Solar Access Design Guidelines specify that the long axis of new dwellings should face within 30 degrees west and 45 degrees east of true south. Because houses in a subdivision usually face the street, planners in San Jose found that the easiest way to achieve solar orientation was to orient the streets

42

Passive solar design strategies: Remodeling guidelines for conserving energy at home  

DOE Green Energy (OSTI)

The idea of passive solar is simple, but applying it effectively does require information and attention to the details of design and construction. Some passive solar techniques are modest and low-cost, and require only small changes in remodeler's typical practice. At the other end of the spectrum, some passive solar systems can almost eliminate a house's need for purchased heating (and in some cases, cooling) energy -- but probably at a relatively high first cost. In between are a broad range of energy-conserving passive solar techniques. Whether or not they are cost-effective, practical and attractive enough to offer a market advantage to any individual remodeler depends on very specific factors such as local costs, climate, and market characteristics. Passive solar design strategies: Remodeling Guidelines For Conserving Energy At Homes is written to help give remodelers the information they need to make these decisions. Passive Solar Design Strategies is a package in three basic parts: The Guidelines contain information about passive solar techniques and how they work, and provides specific examples of systems which will save various percentages of energy; The Worksheets offer a simple, fill-in-the-blank method to pre-evaluate the performance of a specific design; The Worked Example demonstrates how to complete the worksheets for a typical residence.

Not Available

1991-01-01T23:59:59.000Z

43

Passive solar design strategies: Remodeling guidelines for conserving energy at home. [Final report  

DOE Green Energy (OSTI)

The idea of passive solar is simple, but applying it effectively does require information and attention to the details of design and construction. Some passive solar techniques are modest and low-cost, and require only small changes in remodeler`s typical practice. At the other end of the spectrum, some passive solar systems can almost eliminate a house`s need for purchased heating (and in some cases, cooling) energy -- but probably at a relatively high first cost. In between are a broad range of energy-conserving passive solar techniques. Whether or not they are cost-effective, practical and attractive enough to offer a market advantage to any individual remodeler depends on very specific factors such as local costs, climate, and market characteristics. Passive solar design strategies: Remodeling Guidelines For Conserving Energy At Homes is written to help give remodelers the information they need to make these decisions. Passive Solar Design Strategies is a package in three basic parts: The Guidelines contain information about passive solar techniques and how they work, and provides specific examples of systems which will save various percentages of energy; The Worksheets offer a simple, fill-in-the-blank method to pre-evaluate the performance of a specific design; The Worked Example demonstrates how to complete the worksheets for a typical residence.

Not Available

1991-12-31T23:59:59.000Z

44

Passive solar design strategies: Remodeling guidelines for conserving energy at home  

SciTech Connect

The idea of passive solar is simple, but applying it effectively does require information and attention to the details of design and construction. Some passive solar techniques are modest and low-cost, and require only small changes in remodeler's typical practice. At the other end of the spectrum, some passive solar systems can almost eliminate a house's need for purchased heating (and in some cases, cooling) energy -- but probably at a relatively high first cost. In between are a broad range of energy-conserving passive solar techniques. Whether or not they are cost-effective, practical and attractive enough to offer a market advantage to any individual remodeler depends on very specific factors such as local costs, climate, and market characteristics. Passive solar design strategies: Remodeling Guidelines For Conserving Energy At Homes is written to help give remodelers the information they need to make these decisions. Passive Solar Design Strategies is a package in three basic parts: The Guidelines contain information about passive solar techniques and how they work, and provides specific examples of systems which will save various percentages of energy; The Worksheets offer a simple, fill-in-the-blank method to pre-evaluate the performance of a specific design; The Worked Example demonstrates how to complete the worksheets for a typical residence.

1991-01-01T23:59:59.000Z

45

DESIGN FOR ENERGY EFFICIENCY: PROPOSITION OF A GUIDELINES-BASED TOOL  

E-Print Network (OSTI)

1 DESIGN FOR ENERGY EFFICIENCY: PROPOSITION OF A GUIDELINES-BASED TOOL J. Bonvoisin, F. Mathieux, L. Domingo, and D. Brissaud Keywords: ecodesign, energy efficiency, guideline, energy using products (Eu. In spite of all the improvements made to the energy efficiency of several appliances, the savings

Paris-Sud XI, Université de

46

Metal wastage design guidelines for bubbling fluidized-bed combustors. Final report  

Science Conference Proceedings (OSTI)

These metal wastage design guidelines identify relationships between metal wastage and (1) design parameters (such as tube size, tube spacing and pitch, tube bundle and fluidized-bed height to distributor, and heat exchanger tube material properties) and (2) operating parameters (such as fluidizing velocity, particle size, particle hardness, and angularity). The guidelines are of both a quantitative and qualitative nature. Simplified mechanistic models are described, which account for the essential hydrodynamics and metal wastage processes occurring in bubbling fluidized beds. The empirical correlational approach complements the use of these models in the development of these design guidelines. Data used for model and guideline validation are summarized and referenced. Sample calculations and recommended design procedures are included. The influences of dependent variables on metal wastage, such as solids velocity, bubble size, and in-bed pressure fluctuations, are discussed.

Lyczkowski, R.W.; Podolski, W.F.; Bouillard, J.X.; Folga, S.M. [Argonne National Lab., IL (United States)

1992-11-01T23:59:59.000Z

47

Guidelines for preparing criticality safety evaluations at Department of Energy non-reactor nuclear facilities  

SciTech Connect

This document contains guidelines that should be followed when preparing Criticality Safety Evaluations that will be used to demonstrate the safety of operations performed at DOE non-reactor nuclear facilities. Adherence to these guidelines will provide consistency and uniformity in criticality safety evaluations (CSEs) across the complex and will document compliance with the requirements of DOE Order 5480.24.

1993-11-01T23:59:59.000Z

48

Guidelines for selecting a solar heating, cooling or hot water design  

SciTech Connect

Guidelines are presented for the professional who may have to choose between competing solar heating and cooling designs for buildings. The experience of the National Solar Data Network in monitoring over 100 solar installations are drawn upon. Three basic principles and a design selection checklist are developed which will aid in choosing the most cost effective design.

Kelly, C.J. Jr.

1981-12-01T23:59:59.000Z

49

Guidelines for the Uprate Design of Turbine-Generator Rotor Support Systems  

Science Conference Proceedings (OSTI)

The focus of this guidelines document is the rotor support structure for uprated turbine-generator (T/G) systems. The overall objective of the guidelines is to provide utility personnel with the guidance needed to validate the design of the components prior to a plant uprate/upgrade to ensure that the unit will operate without unplanned and unanticipated issues related to the rotor bearings, bearing support structures, and pedestals. The guidelines are applicable to both nuclear and fossil T/G rotor supp...

2011-12-23T23:59:59.000Z

50

1.0 PURPOSE EDG – 5 DESIGN CALCULATIONS ENGINEERING DESIGN GUIDELINES  

E-Print Network (OSTI)

The purpose of this procedure is to provide guidelines to be used during the preparation, control, and retention of design calculations for RTD FasTracks Projects in an effort to: A. Provide a complete, permanent record of the criteria, assumptions, functional requirements and technical methodology used in arriving at the design solution for a project. B. Verify and ensure relevant codes and criteria are used appropriately. C. Verify that the plans and specifications conform to the design. D. Provide reference material for changes during the construction phase and for future alterations to the facility. 2.0 SCOPE The minimum requirements and criteria outlined for design calculations apply to both inhouse and contracted design work. This procedure contains criteria for all of RTD projects including, but not limited to, BRT, CRT, LRT, park-n-Rides and Maintenance Facilities. This procedure offers a summary of expectations, more detailed information can be found in the applicable RTD manuals referenced in Section 4.0 below.

unknown authors

2007-01-01T23:59:59.000Z

51

Materials Reliability Program: Pressurized Water Reactor Internals Inspection and Evaluation Guidelines (MRP-227-A)  

Science Conference Proceedings (OSTI)

The Materials Reliability Program (MRP) developed inspection and evaluation (I&E) guidelines for managing long-term aging reactor vessel internal components of pressurized water reactors (PWRs) reactor internals. Specifically, the guidelines are applicable to reactor vessel internal structural components; they do not address fuel assemblies, reactivity control assemblies, or welded attachments to the reactor vessel.

2011-12-23T23:59:59.000Z

52

Development of design for remanufacturing guidelines to support sustainable manufacturing  

Science Conference Proceedings (OSTI)

Developing sustainable approaches to manufacture is a critical global concern. Key measures towards this include practicing design for environment (ecodesign), for example by improving remanufacturing efficiency and effectiveness. Remanufacturing is ... Keywords: Design for environment, Remanufacture, Sustainable manufacture

Winifred L. Ijomah; Christopher A. McMahon; Geoffrey P. Hammond; Stephen T. Newman

2007-12-01T23:59:59.000Z

53

Creation of an ergonomic guideline for supervisory control interface design  

Science Conference Proceedings (OSTI)

In tasks of human supervision in industrial control room they are applied generic disciplines as the software engineering and the physical ergonomics for the design of the computing interface and the design of the control room layout. From the point ... Keywords: human-machine interface design, supervisory control

Pere Ponsa; Marta Díaz

2007-07-01T23:59:59.000Z

54

Guidelines for the Fluid Dynamic Design of Power Plant Ducts  

Science Conference Proceedings (OSTI)

The design of air and flue gas duct systems for electric power plants is an important but often neglected part of the complete design. By following the procedures outline in this report the duct engineer can develop a cost-effective design that minimizes pressure drop losses and the related operating costs.

1998-04-27T23:59:59.000Z

55

Guidelines for sustainable building design: Recommendations from the Presidio of San Francisco energy efficiency design charrette  

SciTech Connect

In 1994, the Bay Chapter of the Association of Energy Engineers{reg_sign} organized a two-day design charrette for energy-efficient redevelopment of buildings by the National Park Services (NPS) at the Presidio of San Francisco. This event brought together engineers, researchers, architects, government officials, and students in a participatory environment to apply their experience to create guidelines for the sustainable redesign of Presidio buildings. The venue for the charrette was a representative barracks building located at the Main Post of the Presidio. Examination of this building allowed for the development of design recommendations, both for the building and for the remainder of the facilities. The charrette was organized into a committee structure consisting of: steering, measurement and monitoring, modeling, building envelope and historic preservation (architectural), HVAC and controls, lighting, and presentation. Prior to the charrette itself, the modeling and measurement/monitoring committees developed substantial baseline data for the other committees during the charrette. An integrated design approach was initiated through interaction between the committees during the charrette. Later, committee reports were cross-referenced to emphasize whole building design and systems integration.

Brown, K.; Sartor, D.; Greenberg, S. [and others

1996-05-01T23:59:59.000Z

56

Guidelines for the Technical Evaluation of Replacement Items in Nuclear Power Plants (NCIG-11)  

Science Conference Proceedings (OSTI)

Using a systematic technical evaluation process, utilities can ensure that replacement parts for nuclear power plants are equivalent to the originals. Guidelines developed by EPRI and NCIG provide practical information and a systematic approach to procurement.

1990-01-08T23:59:59.000Z

57

Advanced Strategy Guideline: Air Distribution Basics and Duct Design  

SciTech Connect

This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings. Principles discussed that will maximize occupant comfort include delivery of the proper amount of conditioned air for appropriate temperature mixing and uniformity without drafts, minimization of system noise, the impacts of pressure loss, efficient return air duct design, and supply air outlet placement, as well as duct layout, materials, and sizing.

Burdick, A.

2011-12-01T23:59:59.000Z

58

Guidelines for the Evaluation of Seam-Welded High-Energy Piping  

Science Conference Proceedings (OSTI)

The body of available utility experience and data on seam-welded piping inspection and failures has grown considerably since the publication of the first edition of the Guidelines for Evaluation of Seam-Welded Piping in 1987 (CS-4774), as has the body of information on applicable nondestructive evaluation (NDE) methods. Ongoing concern for the integrity of seam-welded high- energy piping motivated EPRI to publish new editions of the Guidelines in 1996, 2001, and 2003 (EPRI reports ...

2012-12-14T23:59:59.000Z

59

Guidelines for the Evaluation of Seam-Welded High-Energy Piping  

Science Conference Proceedings (OSTI)

EPRI published the first edition of the "Guidelines for the Evaluation of Seam-Welded Steam Pipes" in 1987 (EPRI report CS-4774). Subsequent updates of the Guidelines in 1996, 2001, and 2003 have added data on new incidents of pipe cracking and failure, new information concerning damage initiation and propagation phenomena, new and more detailed descriptions of nondestructive examination methods, and modifications to the EPRI evaluation procedures.

2003-12-31T23:59:59.000Z

60

Guidelines and procedures for design of Class 1 elevated temperature nuclear system components  

Science Conference Proceedings (OSTI)

This standard provides guidelines and procedures which may be used by the manufacturer in satisfying the requirements given for design of class 1 elevated temperature nuclear system components. Guidance is given regarding planning and control of design analysis. A sequence for calculations is recommended. Methods of analysis, including procedures to account for environmental effects, are given which are acceptable in principle to the owner. A format is provided for use in documentation of design analyses.

Not Available

1986-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Guidelines for Designing Effective Energy Information Feedback Pilots: Research Protocols  

Science Conference Proceedings (OSTI)

Enhanced and timely information regarding consumers electricity use and costs, known as feedback, may significantly influence their behavior across a broad spectrum of usage and acquisition decisions. Such information feedback has become increasingly important in light of widespread investments in Smart Grid technologies. This report identifies protocols for three phases of energy information feedback pilotsresearch design, analysis, and reportingalong with three example applications. When used as the co...

2010-04-23T23:59:59.000Z

62

Pollution prevention/waste minimization guidelines for facility design  

SciTech Connect

The mission of the 560 square mile (1450 sq Km) Hanford site, located in south eastern Washington, was changed from defense production to environmental restoration and waste management in 1989. The Tri-Party Agreement (TPA) signed in 1989 between DOE, EPA and Washington State, agreed to clean up most of the Hanford site within 30 years. To accomplish the clean-up and comply with the schedule established in the TPA, a number of treatment and support facilities will have to be built. While these facilities are designed to treat wastes that have already been generated, the routine operation and maintenance of these facilities will generate their own wastes. With careful planning, new facilities or modifications to existing facilities can be designed in a manor such that little pollution or waste is generated through normal operation and maintenance. The project the author is working on is concerned with avoiding or reducing the generation of new waste by assuring that pollution prevention and waste minimization are considered in the design phase of these facilities.

Encke, D.B.

1993-04-01T23:59:59.000Z

63

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities (42 U.S.C. 8253 Subsection (f), Use of Energy and Water Efficiency Measures in Federal Buildings) 25 November 2008 I. Background A. Authority Section 432 of the Energy Independence and Security Act of 2007 (EISA) amends section 543 of the National Energy Conservation Policy Act, by adding a new subsection (f) Use of Energy and Water Efficiency Measures in Federal Buildings (42 U.S.C. 8253(f); referred to as "the statute" in this guidance). The new subsection prescribes a framework for facility energy project management and benchmarking, including the following elements: * Designated "facility energy managers" for ensuring compliance of "covered facilities"

64

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities  

NLE Websites -- All DOE Office Websites (Extended Search)

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities (42 U.S.C. 8253 Subsection (f), Use of Energy and Water Efficiency Measures in Federal Buildings) 25 November 2008 I. Background A. Authority Section 432 of the Energy Independence and Security Act of 2007 (EISA) amends section 543 of the National Energy Conservation Policy Act, by adding a new subsection (f) Use of Energy and Water Efficiency Measures in Federal Buildings (42 U.S.C. 8253(f); referred to as "the statute" in this guidance). The new subsection prescribes a framework for facility energy project management and benchmarking, including the following elements: * Designated "facility energy managers" for ensuring compliance of "covered facilities"

65

Design and Manufacturing Guidelines for High-Strength Components in LWRs--Alloy X-750  

Science Conference Proceedings (OSTI)

Alloy X-750, commonly used in high-strength internal reactor components, occasionally experiences intergranular stress corrosion cracking (IGSCC). EPRI's new design and manufacturing guidelines, specifying parameters that can influence IGSCC resistance, will assist utilities in reducing the probability of in-service failures of alloy X-750 components.

1991-05-01T23:59:59.000Z

66

Guidelines for Determining Design Basis Ground Motions: Volumes 1-5  

Science Conference Proceedings (OSTI)

Procedures currently used to assess the nature of earthquake ground motion in Eastern North America introduce considerable uncertainty to the design parameters of nuclear power plants and other critical facilities. This report examines that issue in-depth and provides an engineering model and guideline for selecting a site and assessing its seismic suitability.

1993-12-23T23:59:59.000Z

67

Guidelines for Determining Design Basis Ground Motions: Volumes 1-5  

Science Conference Proceedings (OSTI)

Procedures currently used to assess the nature of earthquake ground motion in Eastern North America introduce considerable uncertainty to the design parameters of nuclear power plants and other critical facilities. This report examines that issue in-depth and provides an engineering model and guideline for selecting a site and assessing its seismic suitability.

1993-12-01T23:59:59.000Z

68

Overview of NCHRP Design Guideline for EPS-Block Geofoam in Slope Stabilization and Repair  

E-Print Network (OSTI)

Manhattan College Bronx, New York 10471 Tel: (718) 826-7177 E-mail: john.horvath@manhattan.edu Dov and repair applications based on the results of National Cooperative Highway Research Program (NCHRP) Project was performed under NCHRP Project 24-11(01) and produced a design guideline for use of EPS blocks in stand

Horvath, John S.

69

Program on Technology Innovation: Decision-Centered Guidelines for the Design of Human System Interfaces for Electric Power Industry Applications  

Science Conference Proceedings (OSTI)

Decision-centered guidelines support improved user decision making across a broad range of electric power industry application areas. The guidelines will aid in the design of user-centered human-system interfaces (HSIs), while increasing the beneficial uses of new technologies for electric power generation, transmission, and distribution (GTD) systems. Decision-centered guidelines are applicable to system designs involving new technology that will transform current user tasks, responsibilities, ...

2012-09-24T23:59:59.000Z

70

Guidelines for evaluation of nuclear facility training programs  

Science Conference Proceedings (OSTI)

This document establishes a single set of objectives and criteria for the evaluation of training programs developed to meet requirements of DOE Orders 5480.18A and 5480.20, and other directives that address training and qualification. The evaluation includes appraisals, surveillances, audits, reviews, assessments, and other activities intended to evaluate training. The standard is intended to assist personnel in performing evaluations of training and qualification programs.

Not Available

1994-06-01T23:59:59.000Z

71

Design and Operating Guidelines Manual for Cooling-Water Treatment - Treatment of Recirculated Cooling Water  

Science Conference Proceedings (OSTI)

This preliminary manual was developed to provide a systematic procedure for evaluating candidate strategies for the treatment of recirculated cooling water. It presents (1) a means of selecting optimal treatment methods and facilities on the basis of technical and economic considerations, and (2) guidelines for proper cooling-water system operation. Descriptions of, and user's manuals for, the cooling-system process and chemical equilibrium computer simulation models are included.

1982-03-01T23:59:59.000Z

72

Energy Design Guidelines for High Performance Schools: Hot and Dry Climates  

Science Conference Proceedings (OSTI)

School districts around the country are finding that smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create an exemplary building that is both energy and resource efficient.

Not Available

2002-01-01T23:59:59.000Z

73

Energy Design Guidelines for High Performance Schools: Temperate and Humid Climates  

SciTech Connect

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

74

Energy Design Guidelines for High Performance Schools: Cool and Dry Climates  

SciTech Connect

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

75

Energy Design Guidelines for High Performance Schools: Cold and Humid Climates  

SciTech Connect

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

76

Energy Design Guidelines for High Performance Schools: Hot and Dry Climates (CD-ROM)  

Science Conference Proceedings (OSTI)

School districts around the country are finding that smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs. The design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-03-01T23:59:59.000Z

77

Energy Design Guidelines for High Performance Schools: Cool and Humid Climates  

SciTech Connect

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

78

Energy Design Guidelines for High Performance Schools: Temperate and Mixed Climates  

SciTech Connect

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

79

Energy Design Guidelines for High Performance Schools: Hot and Dry Climates (Revision)  

SciTech Connect

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

80

Energy Design Guidelines for High Performance Schools: Hot and Humid Climates  

Science Conference Proceedings (OSTI)

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Evaluating the Effects of Power Plants on Aquatic Communities: Guidelines for Selection of Assessment Methods  

Science Conference Proceedings (OSTI)

This report provides guidelines for selecting methods to estimate effects of cooling water withdrawals on aquatic populations and communities. The report is a companion to the EPRI 1999 report TR-112013, "Catalog of Assessment Methods for Evaluating Effects of Power Plant Operations on Aquatic Communities." These two documents describe approaches for estimating the magnitude of cooling water intake structure effects as part of assessing the potential for adverse environmental impact (AEI) under Section 3...

2002-05-24T23:59:59.000Z

82

BWRVIP-139: Vessel and Internals Project, Steam Dryer Inspection and Flaw Evaluation Guidelines  

Science Conference Proceedings (OSTI)

This document provides steam dryer inspection and flaw evaluation guidelines consistent with those developed for other boiling water reactor (BWR) internal components. It includes (1) documentation of the steam dryer configurations for the different plants, (2) a summary of dryer cracking incidents based on field experience, (3) documentation of the regions of susceptibility for fatigue cracking and intergranular stress corrosion cracking (IGSCC), (4) a review of the failure modes and effects of cracking...

2005-04-01T23:59:59.000Z

83

Evaluation of Contemporary Design of Reinforced Concrete ...  

Science Conference Proceedings (OSTI)

Page 1. Evaluation of Contemporary Design of Reinforced Concrete Lateral Resisting Systems Using Current Performance ...

2011-02-16T23:59:59.000Z

84

Evaluation of Chemical Warfare Agent Percutaneous Vapor Toxicity: Derivation of Toxicity Guidelines for Assessing Chemical Protective Ensembles.  

SciTech Connect

Percutaneous vapor toxicity guidelines are provided for assessment and selection of chemical protective ensembles (CPEs) to be used by civilian and military first responders operating in a chemical warfare agent vapor environment. The agents evaluated include the G-series and VX nerve agents, the vesicant sulfur mustard (agent HD) and, to a lesser extent, the vesicant Lewisite (agent L). The focus of this evaluation is percutaneous vapor permeation of CPEs and the resulting skin absorption, as inhalation and ocular exposures are assumed to be largely eliminated through use of SCBA and full-face protective masks. Selection of appropriately protective CPE designs and materials incorporates a variety of test parameters to ensure operability, practicality, and adequacy. One aspect of adequacy assessment should be based on systems tests, which focus on effective protection of the most vulnerable body regions (e.g., the groin area), as identified in this analysis. The toxicity range of agent-specific cumulative exposures (Cts) derived in this analysis can be used as decision guidelines for CPE acceptance, in conjunction with weighting consideration towards more susceptible body regions. This toxicity range is bounded by the percutaneous vapor estimated minimal effect (EME{sub pv}) Ct (as the lower end) and the 1% population threshold effect (ECt{sub 01}) estimate. Assumptions of exposure duration used in CPE certification should consider that each agent-specific percutaneous vapor cumulative exposure Ct for a given endpoint is a constant for exposure durations between 30 min and 2 hours.

Watson, A.P.

2003-07-24T23:59:59.000Z

85

DOE: Assessment Criteria and Guidelines for Determining the Adequacy of Software Used in the Safety Analysis and Design of Defense Nuclear Facilities, 10j/24/03  

Energy.gov (U.S. Department of Energy (DOE))

This document contains software quality assurance (SQA) assessment criteria and guidelines for assessing the safety software currently in use in the safety analysis and design of structures,...

86

Emerging human-computer interface (HCI) design guidelines for graphical user interface (GUI)  

SciTech Connect

The requirement to establish baseline style references for Graphical User Interfaces (GUIs) is recognized. The ability to obtain consensus among user communities has been limited to nonexistent. The authors are part of a team that has developed a generic baseline human-computer interface (HCI) style guide for the U.S. Department of Defense (DoD). The DoD HCI Style Guide has its origin in a style guide developed by the intelligence community and in human factors design guidelines developed for Army tactical command and control systems. The DoD HCI Style Guide is intended to be a baseline style reference for the design of HCIs within DoD. The needs of specific user communities have been addressed by including addenda that expand on the baseline and address focus areas of interest. The conclusion is that an overall or general style guide should be adopted for GUIs with allowance for specialized user group requirements and additions. The anticipated results would be higher productivity and reduced training and development time.

Bowser, S.E.; Adams, S.M.

1993-10-01T23:59:59.000Z

87

Combustion-Turbine Design Guidelines Based on Deposition-Corrosion Considerations, Volume 2: Coal-Derived Liquid Studies  

Science Conference Proceedings (OSTI)

Middle-distillate coal liquids test out as acceptable gas turbine fuels in terms of deposition and corrosion. Solid-liquid slurries would also be acceptable if turbine cleaning techniques were fully used.This series of tests provided design and operating guidelines that would minimize ash deposition and turbine corrosion.

1984-06-01T23:59:59.000Z

88

Clean air program: Design guidelines for bus transit systems using liquefied petroleum gas (LPG) as an alternative fuel. Final report, July 1995-April 1996  

Science Conference Proceedings (OSTI)

The Federal Transit Administration (FTA) has initiated the development of `Design Guidelines for Bus Transit Systems Using Alternative Fuels.` This report provides design guidelines for the safe uses of Liquefied Petroleum Gas (LPG). It forms a part of the series of individual monographs being published by the FTA on (the guidelines for the safe use of) Compressed Natural Gas (CNG), Liquefied Natural Gas (LNG), Liquefied Petroleum Gas (LPG) and alcohol fuels (Methanol and Ethanol). Each report in this series describes for the subject fuel the important fuel properties, guidelines for the design and operation of bus fueling, storage and maintenance facilities, issues on personnel training and emergency preparedness.

Raj, P.K.; Hathaway, W.T.; Kangas, R.

1996-09-01T23:59:59.000Z

89

Guideline for Computer-Based Training (CBT) Development: Volume 1: Instructional System Design Process  

Science Conference Proceedings (OSTI)

Many companies in the utility industry are adopting Computer Based Training (CBT) materials as an integral part of their leaner, cost-conscious training programs. Producing effective CBT, whether with in-house resources or with a development vendor, poses complex challenges to utility training personnel. Personnel new to CBT design and development need assistance in making informed decisions about all phases of the CBT life cycle: Analysis, Design, Development, Implementation, and Evaluation.

1998-10-29T23:59:59.000Z

90

Data Collection Guidelines for Consistent Evaluation of Data from Verification and Monitoring Safeguard Systems  

SciTech Connect

One of the several activities the International Atomic Energy Agency (IAEA) inspectors perform in the verification process of Safeguard operations is the review and correlation of data from different sources. This process is often complex due to the different forms in which the data is presented. This paper describes some of the elements that are necessary to create a ''standardized'' structure for the verification of data. When properly collected and formatted, data can be analyzed with off-the shelf software applications using customized macros to automate the commands for the desired analysis. The standardized-data collection methodology is based on instrumentation guidelines as well as data structure elements, such as verifiable timing of data entry, automated data logging, identification codes, and others. The identification codes are used to associate data items with their sources and to correlate them with items from other data logging activities. The addition of predefined parameter ranges allows automated evaluation with the capability to provide a data summary, a cross-index of all data related to a specific event. Instances of actual databases are used as examples. The data collection guidelines described in this paper facilitate the use of data from a variety of instrumentation platforms and also allow the instrumentation itself to be more easily applied in subsequent monitoring applications.

Castleberry, K.; Lenarduzzi, R.; Whitaker, M.

1999-09-20T23:59:59.000Z

91

Nuclear Plant Design and Modification Guidelines for PWR Steam Generator Reliability  

Science Conference Proceedings (OSTI)

Operating and maintenance experience relative to PWR steam generator reliability has produced a variety of "lessons learned." This information has been incorporated in a series of guidelines to aid utilities in major plant modifications and new plant construction.

1991-09-25T23:59:59.000Z

92

Materials Reliability Program: Inspection and Evaluation Guidelines for Reactor Vessel Bottom-Mounted Nozzles in U.S. PWR Plants (MR P-206)  

Science Conference Proceedings (OSTI)

This report presents inspection and evaluation guidelines for reactor vessel bottom-mounted nozzles in U.S. pressurized water reactor (PWR) plants.

2009-03-23T23:59:59.000Z

93

Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification: Guidelines for Planning, Specifi cation, Design, Licensing, Implementation, Training, Operation, and Maintenance  

Science Conference Proceedings (OSTI)

Operators of nuclear power plants face a significant challenge designing and modifying control rooms that will be produced at various stages of instrumentation and control modernization. This report provides guidance on planning, specifying, designing, implementing, operating, maintaining, and training for modernized control rooms and digital human-system interfaces. Much of the guidance also will support new plant control rooms. This report also presents detailed information and guidelines on specific t...

2004-11-29T23:59:59.000Z

94

Guideline for the Evaluation and Treatment of Corrosion and Fouling in Fire Protection Systems  

Science Conference Proceedings (OSTI)

This guideline document addresses the methods to control and mitigate corrosion, fouling, and microbiological growth in water-related fire protection systems (FPSs).

1999-03-30T23:59:59.000Z

95

Evaluating web site accessibility: validating the WAI guidelines through usability testing with disabled users  

Science Conference Proceedings (OSTI)

The purpose of the reported study has been to validate empirically the usefulness of using the WAI accessibility guidelines WCAG 1.0 as a heuristic for website accessibility. Through controlled usability tests of two websites with disabled users (N=7) ... Keywords: WCAG, accessibility, guidelines, usability, usability testing, validation

Dagfinn Rømen; Dag Svanæs

2008-10-01T23:59:59.000Z

96

Ecologic Oriented Development (EOD): To create guidelines for ecologic site and infrastructure design that are  

E-Print Network (OSTI)

#12;Ecologic Oriented Development (EOD): GOALS · To create guidelines for ecologic site plan. #12;Ecologic Oriented Development (EOD): PROCESS · ANALYSIS of Landscape Units, Mapping and Site Principles For Ecologic Oriented Development (EOD) 1. COMPLETE WASTE AND WATER CYCLES 2. INTEGRATED

Ishii, Hiroshi

97

DOE G 430.1-1 Chp 25, Guidelines for Engineering, Design, and Inspection Costs  

Directives, Delegations, and Requirements

This chapter addresses engineering, design, and inspection activities that begin with preliminary design (Title I).

1997-03-28T23:59:59.000Z

98

HVAC Energy Recovery Design and Economic Evaluation  

E-Print Network (OSTI)

ENRECO has prepared this paper on HVAC energy recovery to provide the engineer with an overview of the design engineering as well as the economic analysis considerations necessary to evaluate the potential benefits of energy recovery.

Kinnier, R. J.

1979-01-01T23:59:59.000Z

99

Clean air program: Design guidelines for bus transit systems using alcohol fuel (methanol and ethanol) as an alternative fuel. Final report, July 1995-April 1996  

Science Conference Proceedings (OSTI)

This report provides design guidelines for the safe use of alcohol fuel (Methanol or Ethanol). It is part of a series of individual monographs being published by the FTA providing guidelines for the safe use of Compressed Natural Gas (CNG), Liquefied Natural Gas (LNG), Liquefied Petroleum Gas (LPG) and alcohol fuels (Methanol and Ethanol). Each report in this series describes, for the subject fuel, the important fuel properties, guidelines for the design and operation of bus fueling, storage and maintenance facilities, issues on personnel training and emergency preparedness.

Raj, P.K.; DeMarco, V.R.; Hathaway, W.T.; Kangas, R.

1996-08-01T23:59:59.000Z

100

Evaluation of commercially available lighting design software  

Science Conference Proceedings (OSTI)

This report addresses the need for commercially available lighting design computer programs and evaluates several of these programs. Sandia National Laboratories uses these programs to provide lighting designs for exterior closed-circuit television camera intrusion detection assessment for high-security perimeters.

McConnell, D.G.

1990-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Resources, and the United States Environmental Protection AgencyDesigning Rate Structures that Support Your Objectives: Guidelines for NC Water Systems  

E-Print Network (OSTI)

The purpose for these rate setting guidelines is to provide water and wastewater utility managers and technical assistance providers with a framework in setting water and wastewater rates and rate structures that would meet the state’s and the utility’s policies and objectives. These guidelines provide step by step instructions and necessary information to allow the utility manager to make an informed policy-driven choice on the rate structure design. These guidelines do not provide instruction on how to project revenues and costs and how to calculate rates (dollar amounts) to balance a budget, but references other documents that provide such guidelines. These rate setting guidelines were developed by the Environmental Finance Center at the

unknown authors

2009-01-01T23:59:59.000Z

102

BWRVIP-18, Revision 1-A: BWR Vessel and Internals Project, BWR Core Spray Internals Inspection and Flaw Evaluation Guidelines  

Science Conference Proceedings (OSTI)

The Boiling Water Reactor Vessel and Internals Project (BWRVIP), formed in June 1994, is an association of utilities focused exclusively on boiling water reactor (BWR) vessel and internals issues. This BWRVIP report contains generic guidelines that describe locations on the core spray piping and spargers for which inspection is needed, categories of plants for which inspection needs would differ, extent of inspection and reinspection for each location, and flaw evaluation procedures to determine ...

2012-04-09T23:59:59.000Z

103

SOLERAS - Solar Cooling Engineering Field Tests Project: United Technologies Research Center. Design guidelines for solar heating/cooling/power generation systems  

Science Conference Proceedings (OSTI)

This report documents the methodology, design guidelines and analytical tools for the preliminary technical/economic evaluation of solar heating/cooling/power generation systems. In particular, it provides the theoretical framework, data bases and software tools for: determining the preliminary economic feasibility of solar-powered configurations compared with grid-supplied electric power and/or competing fossil fuels; selecting the optimum system configuration with respect to solar collector area and ''solar-side'' thermal storage capacity. Implementation of the methodology described in this report can be facilitated by the use of the accompanying IBM PC-compatible computer program ''SOLERAS''. This report represents the final task of the multi-year SOLERAS Program -- jointly sponsored by the US Department of Energy and the King Abdulaziz City for Science and Technology -- which involved the development and field-testing of a solar-powered cooling system in Phoenix, AZ. 11 refs., 37 figs.

Not Available

1987-01-01T23:59:59.000Z

104

Duct injection for SO{sub 2} control, Design Handbook, Volume 1, Process design and engineering guidelines  

SciTech Connect

PETC developed a comprehensive program of coal-related, acid-rain research and development with a major activity area centering on flue gas cleanup and control of SO{sub 2} emissions. Particular emphasis was placed on the retrofit measures for older coal-fired power plants which predate the 1971 New Source Performance Standards. Candidate emission control technologies fall into three categories, depending upon their point of application along the fuel path (i.e., pre, during, or post combustion). The post-combustion, in-duct injection of a calcium-based chemical reagent seemed promising. Preliminary studies showed that reagent injection between the existing air heater and electrostatic precipitator (ESP) could remove between 50-60% of the SO{sub 2} and produce an environmentally safe, dry, solid waste that is easily disposed. Although SO{sub 2} removal efficiencies were less, the estimated capital costs for duct injection technology were low making the economics of duct injection systems seem favorable when compared to conventional wet slurry scrubbers under certain circumstances. With the promulgation of the Clean Air Act Amendments of 1990 came more incentive for the development of low capital cost flue gas desulfurization (FGD) processes. A number of technical problems had to be resolved, however, before duct injection technology could be brought to a state of commercial readiness. The Duct Injection Technology Development Program was launched as a comprehensive, four-year research effort undertaken by PETC to develop this new technology. Completed in 1992, this Duct Injection Design Handbook and the three-dimensional predictive mathematical model constitute two primary end products from this development program. The aim of this design handbook and the accompanying math model is to provide utility personnel with sufficient information to evaluate duct injection technology against competing SO{sub 2} emissions reduction strategies for an existing plant.

NONE

1995-09-01T23:59:59.000Z

105

Proposal for an extension of traditional named entities: from guidelines to evaluation, an overview  

Science Conference Proceedings (OSTI)

Within the framework of the construction of a fact database, we defined guidelines to extract named entities, using a taxonomy based on an extension of the usual named entities definition. We thus defined new types of entities with broader coverage including ...

Cyril Grouin; Sophie Rosset; Pierre Zweigenbaum; Karën Fort; Olivier Galibert; Ludovic Quintard

2011-06-01T23:59:59.000Z

106

Assessment of EPRI Fuel Reliability Guidelines for New Nuclear Plant Designs  

Science Conference Proceedings (OSTI)

As the nuclear power industry pursues the licensing, construction and operation of new advanced LWR designs to meet growing electrical demand, a high level of fuel reliability will be a key factor in the ultimate acceptance and sustainability of these new plants. The new reactor designs under consideration by the industry will utilize fuel assembly/rod designs and operating conditions that are similar to the current fleet. This report assesses the applicability of the EPRI Fuel Reliability Program (FRP) ...

2009-12-09T23:59:59.000Z

107

ANL/APS/TB-44, Guidelines for Beamline and Front-End Radiation Shielding Design at the Advanced Photon Source  

NLE Websites -- All DOE Office Websites (Extended Search)

APS/TB-44 Rev. 4 APS/TB-44 Rev. 4 Guidelines for Beamline and Front-End Radiation Shielding Design at the Advanced Photon Source Revision 4 Advanced Photon Source About Argonne National Laboratory Argonne is a U.S. Department of Energy laboratory managed by UChicago Argonne, LLC under contract DE-AC02-06CH11357. The Laboratory's main facility is outside Chicago, at 9700 South Cass Avenue, Argonne, Illinois 60439. For information about Argonne and its pioneering science and technology programs, see www.anl.gov. Availability of This Report This report is available, at no cost, at http://www.osti.gov/bridge. It is also available on paper to the U.S. Department of Energy and its contractors, for a processing fee, from: U.S. Department of Energy Office of Scientific and Technical Information

108

Residential building design : comprehensive comparative guidelines for building single-family dwellings in Hawaii  

E-Print Network (OSTI)

Energy shortages, earthquakes, and hurricanes are environmental factors that challenge the home designers of Hawaii. The depletion of renewable natural resources and global warming trends foreshadow energy shortage and the ...

Nagata, Rochelle Morie

1997-01-01T23:59:59.000Z

109

Design Guidelines for Technology-Mediated Social Interaction in a Presence Sensing Physical Space  

E-Print Network (OSTI)

needs and the social dynamics of the home is necessary to drive the design of home-based ubiquitous step in providing assisted living solutions in home-based environments. Our research is focused on how

Sadeh, Norman M.

110

Environmental design guidelines for a second generation, LEO, permanently manned space station  

E-Print Network (OSTI)

This thesis is a continuation of the thoughts and efforts of the author's participation and co-organization of the Space Station Design Workshop (SSDW). The SSDW was a student run event whose inception surfaced in the ...

Johnson, David Michael, 1960-

1987-01-01T23:59:59.000Z

111

Heat Recovery Steam Generator Procurement Guideline: HRSG Design Best Practices and Specification for Cyclic Duty  

Science Conference Proceedings (OSTI)

This document provides a summary of best practices for designing a new heat recovery steam generator (HRSG) for cycling and rapid start duty, including typical performance requirements and suggestions for design improvements to improve the HRSGs ability to handle cyclic operation. This document also provides a generic procurement specification for the definition and purchase of an HRSG for installation downstream of a combustion turbine. It includes both horizontal and vertical configuration options. The...

2009-12-16T23:59:59.000Z

112

Wind Turbine Design Guideline DG03: Yaw and Pitch Rolling Bearing Life  

DOE Green Energy (OSTI)

This report describes the design criteria, calculation methods, and applicable standards recommended for use in performance and life analyses of ball and roller (rolling) bearings for yaw and pitch motion support in wind turbine applications. The formulae presented here for rolling bearing analytical methods and bearing-life ratings are consistent with methods in current use by wind turbine designers and rolling-bearing manufacturers.

Harris, T.; Rumbarger, J. H.; Butterfield, C. P.

2009-12-01T23:59:59.000Z

113

Low-Energy Building Design Guidelines: Energy-Efficient Design for New Federal Facilities. Federal Energy Management Program (FEMP) Booklet  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Introduction Introduction Incorporating energy efficiency, renewable energy, and sustainable green design features into all Federal buildings has become a top priority in recent years for facilities managers, designers, contracting officers, and others in government buildings procurement. These progressive design strategies have been formalized through Executive Order 13123 (known as Greening the Government through Efficient Energy Management), which was issued on June 3, 1999. There are significant oppor- tunities to accomplish the goals set forth in the executive order, whether in new building design or in the context of renovations. This guidebook addresses the first category-the design process for new Federal facilities. Because energy-efficient buildings reduce both resource depletion and the

114

Experimental measurements and design guidelines for real-time software encryption in multimedia wireless LANs  

Science Conference Proceedings (OSTI)

To secure interactive multimedia applications in wireless LANs (WLANs), it is pertinent to implement real time cryptographic services. In this paper we evaluate the use of software based encryption algorithms that are implemented in the ...

Aura Ganz; Se Hyun Park; Zvi Ganz

1999-01-01T23:59:59.000Z

115

International Energy Agency design tool evaluation procedure  

Science Conference Proceedings (OSTI)

Detailed state-of-the-art building energy simulation models from nations participating in International Energy Agency (IEA) Task VIII are used to develop a quantitative procedure to evaluate more simplified design tools. Simulations are performed with the detailed models on a series of cases that progress systematically from the extremely simple to the relatively realistic. Output values for the cases, such as annual loads, annual maximum and minimum temperatures, and peak loads, are used to set target ranges with which the results from more simplified design tools can be compared. The more realistic cases, although geometrically simple, test the ability of the design tools to model such combined effects as thermal mass, direct gain windows, overhangs, internally generated heat, and dead-band and set-back thermostat control strategies. 5 refs., 9 figs., 4 tabs.

Judkoff, R.; Barakat, S.; Bloomfield, D.; Poel, B.; Stricker, R.; van Haaster, P.; Wortman, D.

1988-07-01T23:59:59.000Z

116

Design and Operating Guidelines for Condensate Polishers in Nuclear Power Plants  

Science Conference Proceedings (OSTI)

Control of impurity ingress to PWR steam generators is essential to prevent significant corrosion damage. A properly designed and operated condensate polisher system can significantly reduce the quantity of impurities transported to steam generators and can provide a measure of protection in the event of a condenser leak.

1991-09-19T23:59:59.000Z

117

Acoustical and Noise Control Criteria and Guidelines for Building Design and Operations  

E-Print Network (OSTI)

Noise, vibration and acoustical design, construction, commissioning and operation practices influence building cost, efficiency, performance and effectiveness. Parameters for structural vibration, building systems noise, acoustics and environmental noise crossing property boundaries will be presented with brief case studies illustrating noise and vibration problems with successful solutions. Building mechanical, power, and plumbing systems contribute to building operations noise and vibration, which affects building occupants, sensitive installations, and functional uses. Various noise and vibration design criteria, field measurements, design concepts and specifications can be applied in facilities to achieve noise mitigation and vibration control to enhance building operations and reduce tenant or neighbor problems. Concepts for enhancement will be presented that achieve specific program criteria and improve the built environment for occupants and functional uses, including items to incorporate in specifications and construction documents. Concepts relating to noise and vibration control can also reduce short and long-term operations costs and save energy. Acoustical designs can be implemented in new construction to achieve specific requirements for LEED certification in healthcare and educational facilities. Common problems, objective criteria, sensitive installations, and solutions will be presented to offer a basic understanding of effective noise and vibration control for central plant equipment, power systems, transformers, standby generators, and roof mounted HVAC equipment.

Evans, J. B.; Himmel, C. N.

2009-11-01T23:59:59.000Z

118

Design and Evaluation of Alternative Cogeneration Systems  

E-Print Network (OSTI)

In the fall of 1973, the Electric Power Research Institute (EPRIY initiated a program for design and evaluation of alternate cogeneration systems. The primary objective of the study is to analyze the overall system (industry and utility) value of cogeneration. A state-of the-art assessment of cogeneration was initiated, in which 17 cogeneration systems were studied in detail. Following the Completion of the case studies, project definition was begun to determine preferred cogeneration systems. From this activity a screening model was developed. The model will be linked to existing methodology to assess the question of capacity credit. Concurrent to the development of the model are a series of cogeneration conceptual designs. The first of these have been completed for pulp and paper industry. The designs were done for two 1985 market pulp mills: one in New England, and the other in the Northwest. The second set of conceptual designs are being performed for two enhanced oil recovery sites. Two additional site specific conceptual designs are planned.

Mauro, R. L.; Hu, S. D.

1982-01-01T23:59:59.000Z

119

Predictive Maintenance Assessment Guidelines  

Science Conference Proceedings (OSTI)

This document is the third in a series of guidelines designed to help electric power utilities develop programs that take advantage of diagnostic technologies used to detect problems in machinery. The PDM Assessment Guidelines provide the procedures necessary to plan and implement a plant wide predictive maintenance program.

1997-12-02T23:59:59.000Z

120

Measure Guideline: Ventilation Cooling  

SciTech Connect

The purpose of this measure guideline on ventilation cooling is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

Springer, D.; Dakin, B.; German, A.

2012-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

New York City Transit Authority design guidelines. Power. Technical studies report  

SciTech Connect

The Power Standards for new lines provide the basic concepts for the design of traction power systems for new routes. The Standards describe the criteria used for the determination of the power requirements, the parameters used in the selection of substation sites and the types of electrical equipment employed for the conversion of High Tension AC power to DC traction power. They include the techniques used to control the power system from one control point and the means by which each substation can be controlled in the event of a supervisory cable failure. The Standards also describe the methods employed to give maximum safety in the substations and on the railroad in case of faults or emergencies. These guides should prove helpful in the design of traction power systems for new routes. (GRA)

1975-03-01T23:59:59.000Z

122

Design and evaluate finned tube bundles  

Science Conference Proceedings (OSTI)

Finned tube bundles are widely used in heat exchangers, air coolers, waste heat boilers and fired heaters where energy transfer occurs between clean flue gases and a fluid with a high heat-transfer coefficient. They have several advantages including compactness, low gas pressure drop and low weight for a given duty compared to bare tube bundles. Choosing a fin type, arrangement and fin configuration requires a thorough analysis and economic evaluation. The solution is not unique since it depends on material and labor costs. Surface areas vary widely in finned tube designs for the same duty and gas pressure drop. Therefore, decisions should not be based on surface area alone. Plant engineers and consultants should consider operating costs in their evaluation because they accrue year after year. Selecting a boiler based on initial costs alone is not prudent. The paper discusses heat transfer and gas pressure drop with finned tubes, determining fin efficiency and effectiveness,g as pressure drop, tube wall and fin top temperatures, an example calculation, the effect of fin configuration on design, the effect of inline versus staggered arrangements and solid versus serrated fins, and concerns with high fin-density designs.

Ganapathy, V. [ABCO Industries, Abilene, TX (United States)

1996-09-01T23:59:59.000Z

123

Structural evaluation in the design of electrorefiner  

SciTech Connect

The electrorefiner is one piece of the process equipment for the Integral Fast Reactor (IFR) program. Its principal components include a primary vessel, a heater assembly, a support-structure assembly, a cover assembly, four electrode assemblies, four elevator and rotator assemblies, and a cover-gas system. In addition, there are various miscellaneous tools and fixtures. The electrorefiner is to be installed within an existing enclosed cell. Design requirements dictate that all equipment within the cell should not be anchored. To assess the integrity of the electrorefiner during operational and seismic loads, extensive structural analyses have been performed. This paper presents some of the major structural evaluations for the electrorefiner and its auxiliary equipment. Results show that the design code requirements are satisfied, and the integrity of the electrorefiner will not be jeopardized during operational and seismic loadings.

Wu, Ting-shu; Blomquist, C.A.; Herceg, J.E.

1995-06-01T23:59:59.000Z

124

Early Site Permit Demonstration Program: Guidelines for determining design basis ground motions. Volume 1  

SciTech Connect

This report develops and applies a methodology for estimating strong earthquake ground motion. The motivation was to develop a much needed tool for use in developing the seismic requirements for structural designs. An earthquake`s ground motion is a function of the earthquake`s magnitude, and the physical properties of the earth through which the seismic waves travel from the earthquake fault to the site of interest. The emphasis of this study is on ground motion estimation in Eastern North America (east of the Rocky Mountains), with particular emphasis on the Eastern United States and southeastern Canada. Eastern North America is a stable continental region, having sparse earthquake activity with rare occurrences of large earthquakes. While large earthquakes are of interest for assessing seismic hazard, little data exists from the region to empirically quantify their effects. Therefore, empirically based approaches that are used for other regions, such as Western North America, are not appropriate for Eastern North America. Moreover, recent advances in science and technology have now made it possible to combine theoretical and empirical methods to develop new procedures and models for estimating ground motion. The focus of the report is on the attributes of ground motion in Eastern North America that are of interest for the design of facilities such as nuclear power plants. Specifically considered are magnitudes M from 5 to 8, distances from 0 to 500 km, and frequencies from 1 to 35 Hz.

Not Available

1993-03-18T23:59:59.000Z

125

Early Site Permit Demonstration Program: Guidelines for determining design basis ground motions. Volume 2, Appendices  

SciTech Connect

This report develops and applies a methodology for estimating strong earthquake ground motion. The motivation was to develop a much needed tool for use in developing the seismic requirements for structural designs. An earthquake`s ground motion is a function of the earthquake`s magnitude, and the physical properties of the earth through which the seismic waves travel from the earthquake fault to the site of interest. The emphasis of this study is on ground motion estimation in Eastern North America (east of the Rocky Mountains), with particular emphasis on the Eastern United States and southeastern Canada. Eastern North America is a stable continental region, having sparse earthquake activity with rare occurrences of large earthquakes. While large earthquakes are of interest for assessing seismic hazard, little data exists from the region to empirically quantify their effects. The focus of the report is on the attributes of ground motion in Eastern North America that are of interest for the design of facilities such as nuclear power plants. This document, Volume II, contains Appendices 2, 3, 5, 6, and 7 covering the following topics: Eastern North American Empirical Ground Motion Data; Examination of Variance of Seismographic Network Data; Soil Amplification and Vertical-to-Horizontal Ratios from Analysis of Strong Motion Data From Active Tectonic Regions; Revision and Calibration of Ou and Herrmann Method; Generalized Ray Procedure for Modeling Ground Motion Attenuation; Crustal Models for Velocity Regionalization; Depth Distribution Models; Development of Generic Site Effects Model; Validation and Comparison of One-Dimensional Site Response Methodologies; Plots of Amplification Factors; Assessment of Coupling Between Vertical & Horizontal Motions in Nonlinear Site Response Analysis; and Modeling of Dynamic Soil Properties.

Not Available

1993-03-18T23:59:59.000Z

126

Development of Design Guidelines for Soil Embedded Post Systems Using Wide-flange I-beam to Contain Truck Impact  

E-Print Network (OSTI)

Anti ram perimeter barriers are part of the protection of important facilities such as power plants, air ports and embassies against unrestricted vehicle access. Many different systems can be used to achieve the containment goal. One of these systems makes use of soil embedded posts either single posts if the soil is hard enough or groups of soil embedded posts tied together by beams if the soil is not hard enough for a single post to stop the in-coming truck. The design of these soil embedded posts needs to take account a number of influencing factors which include the soil strength and stiffness, the post strength and stiffness, the mass of the vehicle and its approach velocity. This dissertation describes the work done to develop a set of design recommendations to select the embedment of a single post or group of posts. The post is a steel beam with an H shape cross section: W14X109 for the single post system and W14X90 for the group system with a double beam made of square hollow steel section HSS8X8X1/2. The spacing of the posts for the group includes 2.44 m, 4.88 m, and 7.32 m. The soil strength varies from loose sand and soft clay to very dense sand and very hard clay. The vehicle has a mass of 6800 kg and the velocities include 80 km/h, 65 km/h, and 50 km/h. The design guidelines presented here are based on 10 medium scale pendulum impact tests, 2 medium scale bogie impact tests, 1 full scale impact test on a single post, 1 full scale impact test on a group of 8 side by side posts with a 5.2 m spacing and connected with two beams, approximately 150 4-D numerical simulations of full scale impact tests using LS-DYNA, as well as fundamental theoretical concepts.

Lim, Seok Gyu

2011-05-01T23:59:59.000Z

127

Guidelines for the Monitoring, Evaluation, Reporting, Verification, and Certification of Forestry Projects for Climate Change Mitigation  

E-Print Network (OSTI)

1993. “Future Biomass-Based Electricity Supply in in. thesupply sector. Thus, the monitoring and evaluation of the impacts of biomass

Vine, Edward; Sathaye, Jayant; Makundi, Willy

1999-01-01T23:59:59.000Z

128

Cost analysis guidelines  

Science Conference Proceedings (OSTI)

The first phase of the Depleted Uranium Hexafluoride Management Program (Program)--management strategy selection--consists of several program elements: Technology Assessment, Engineering Analysis, Cost Analysis, and preparation of an Environmental Impact Statement (EIS). Cost Analysis will estimate the life-cycle costs associated with each of the long-term management strategy alternatives for depleted uranium hexafluoride (UF6). The scope of Cost Analysis will include all major expenditures, from the planning and design stages through decontamination and decommissioning. The costs will be estimated at a scoping or preconceptual design level and are intended to assist decision makers in comparing alternatives for further consideration. They will not be absolute costs or bid-document costs. The purpose of the Cost Analysis Guidelines is to establish a consistent approach to analyzing of cost alternatives for managing Department of Energy`s (DOE`s) stocks of depleted uranium hexafluoride (DUF6). The component modules that make up the DUF6 management program differ substantially in operational maintenance, process-options, requirements for R and D, equipment, facilities, regulatory compliance, (O and M), and operations risk. To facilitate a consistent and equitable comparison of costs, the guidelines offer common definitions, assumptions or basis, and limitations integrated with a standard approach to the analysis. Further, the goal is to evaluate total net life-cycle costs and display them in a way that gives DOE the capability to evaluate a variety of overall DUF6 management strategies, including commercial potential. The cost estimates reflect the preconceptual level of the designs. They will be appropriate for distinguishing among management strategies.

Strait, R.S.

1996-01-10T23:59:59.000Z

129

Richards Barrier LA Reference Design Feature Evaluation  

Science Conference Proceedings (OSTI)

The Richards Barrier is one of the design features of the repository to be considered for the License Application (LA), Richards was a soil scientist who first described the diversion of moisture between two materials with different hydrologic properties. In this report, a Richards Barrier is a special type of backfill with a fine-grained material (such as sand) overlaying a coarse-grained material (such as gravel). Water that enters an emplacement drift will first encounter the fine-grained material and be transported around the coarse-grained material covering the waste package, thus protecting the waste package from contact with most of the groundwater. The objective of this report is to discuss the benefits and liabilities to the repository by the inclusion of a Richards Barrier type backfill in emplacement drifts. The Richards Barrier can act as a barrier to water flow, can reduce the waste package material dissolution rate, limit mobilization of the radionuclides, and can provide structural protection for the waste package. The scope of this report is to: (1) Analyze the behavior of barrier materials following the intrusion of groundwater for influxes of 1 to 300 mm per year. The report will demonstrate diversion of groundwater intrusions into the barrier over an extended time period when seismic activity and consolidation may cause the potential for liquefaction and settlement of the Richards Barrier. (2) Review the thermal effects of the Richards Barrier on material behavior. (3) Analyze the effect of rockfall on the performance of the Richards Barrier and the depth of the barrier required to protect waste packages under the barrier. (4) Review radiological and heating conditions on placement of multiple layers of the barrier. Subsurface Nuclear Safety personnel will perform calculations to determine the radiation reduction-time relationship and shielding capacity of the barrier. (5) Evaluate the effects of ventilation on cooling of emplacement drifts and dusting potential. (6) Evaluate drift conditions and configurations to determine the suitability of Richards Barrier installation methodology. (7) Perform cost assessment of barrier material placement. (8) Evaluate the feature with criteria that will be supplied by the License Application Design Selection (LADS) Team. (9) Comment on the use of depleted uranium as a Richards Barrier material.

N.E. Kramer

1999-11-17T23:59:59.000Z

130

Designing CPV Receivers With Reliability: Early Evaluation of Components  

E-Print Network (OSTI)

Designing CPV Receivers With Reliability: Early Evaluation of Components Objective Materials from power electronics industry must be proven when integrated in PV applications. Pre-qualification tests improves the receiver design and reliability. ANU microconcentrator test&design experience

131

October 24, 2003, Assessment Criteria and Guidelines for Determining the Adequacy of Software Used in the Safety Analysis and Design of Defense Nuclear Facilities  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4.1 4.1 Revision 3 October 24, 2003 U. S. Department of Energy Assessment Criteria and Guidelines for Determining the Adequacy of Software Used in the Safety Analysis and Design of Defense Nuclear Facilities October 24, 2003 CRAD - 4.2.4.1 Revision 3 October 24, 2003 ii TABLE OF CONTENTS ACRONYMS ..................................................................................................................................iii GLOSSARY ...................................................................................................................................iv 1.0 INTRODUCTION ...............................................................................................................1 2.0 BACKGROUND .................................................................................................................2

132

Nondestructive Evaluation: Guideline for Conducting Ultrasonic Examinations of Dissimilar Metal Welds, Revision 1  

Science Conference Proceedings (OSTI)

Operational experience (OE) with in-service inspection (ISI) of nuclear power plants (NPP) includes cases in which human error or poor planning practices resulted in issues with the application of qualified nondestructive evaluation (NDE) procedures. These issues can result in degraded examination performance such as incomplete examination coverage, identification of service-induced defects where none exist, or failure to identify service-induced defects. Applications of recent interest have ...

2013-05-22T23:59:59.000Z

133

Assembly Design and Evaluation in an Augmented Reality Environment  

E-Print Network (OSTI)

The technologies and methodologies of assembly design and evaluation in the early design stage are highly significant to product development. This paper looks at a promising technology to mix real components (e.g. physical ...

Pang, Y.

134

Seismic design and evaluation criteria based on target performance goals  

SciTech Connect

The Department of Energy utilizes deterministic seismic design/evaluation criteria developed to achieve probabilistic performance goals. These seismic design and evaluation criteria are intended to apply equally to the design of new facilities and to the evaluation of existing facilities. In addition, the criteria are intended to cover design and evaluation of buildings, equipment, piping, and other structures. Four separate sets of seismic design/evaluation criteria have been presented each with a different performance goal. In all these criteria, earthquake loading is selected from seismic hazard curves on a probabilistic basis but seismic response evaluation methods and acceptable behavior limits are deterministic approaches with which design engineers are familiar. For analytical evaluations, conservatism has been introduced through the use of conservative inelastic demand-capacity ratios combined with ductile detailing requirements, through the use of minimum specified material strengths and conservative code capacity equations, and through the use of a seismic scale factor. For evaluation by testing or by experience data, conservatism has been introduced through the use of an increase scale factor which is applied to the prescribed design/evaluation input motion.

Murray, R.C.; Nelson, T.A. [Lawrence Livermore National Lab., CA (United States); Kennedy, R.P. [Structural Mechanics Consulting, Inc., Yorba Linda, CA (United States); Short, S.A. [EQE International, Inc., Irvine, CA (United States)

1994-04-01T23:59:59.000Z

135

The design, implementation, and evaluation of Jade  

Science Conference Proceedings (OSTI)

Jade is a portable, implicitly parallel language designed for exploiting task-level concurrency.Jade programmers start with a program written in a standard serial, imperative language, then use Jade constructs to declare how parts of the program access ... Keywords: parallel computing, parallel programming languages

Martin C. Rinard; Monica S. Lam

1998-05-01T23:59:59.000Z

136

WATERMAN: Technical and Economic Guidelines for Evaluating Power Plant Water Management Options: Volumes 1 and 2: Volumes 1 and 2  

Science Conference Proceedings (OSTI)

The WATERMAN code is the first software specifically designed to assist utility engineers and chemists in developing and revising complex integrated power plant water balances. As such, this IBM PC code enables quick and accurate assessments of water uses throughout the plant, identifies recycle/reuse options, and evaluates the impacts of such options on plant makeup water needs, process water chemistry, and wastewater treatment requirements.

1991-09-01T23:59:59.000Z

137

Clean air program: Design guidelines for bus transit systems using hydrogen as an alternative fuel. Final report, September 1997--May 1998  

SciTech Connect

Alternative fuels such as Compressed Natural Gas (CNG), Liquefied Natural Gas (LNG), Liquified Petroleum Gas (LPG), and alcohol fuels (methanol and ethanol) are already being used in commercial vehicles and transit buses in revenue service. Hydrogen, which has better air quality characteristics as a vehicle fuel, is being used in research demonstration projects in fuel cell powered buses, as well as in internal combustion engines in automobiles and small trucks. At present, there are no facility guidelines to assist transit agencies (and others) contemplating the use of hydrogen as an alternative fuel. This document addresses the various issues involved. Hydrogen fuel properties, potential hazards, fuel requirements for specified levels of bus service, applicable codes and standards, ventilation, and electrical classification are indicated in this document. These guidelines also present various facility and bus design issues that need to be considered by a transit agency to ensure safe operations when using hydrogen as an alternative fuel. Fueling facility, garaging facility, maintenance facility requirements and safety practices are discussed. Critical fuel-related safety issues in the design of the related system on the bus are also identified. A system safety assessment and hazard resolution process is also presented. This approach may be used to select design strategies which are economical, yet ensure a specified level of safety.

Raj, P.K.; Hathaway, W.T.; Kangas, R.A.

1998-10-01T23:59:59.000Z

138

Guidelines for the Nondestructive Examination of Boilers  

Science Conference Proceedings (OSTI)

As the boiler fleet ages, new demands are being placed upon them including operating in cycling modes for which they were not originally designed. Operators are experiencing an increasing incidence of boiler tube failures (BTFs). These guidelines provide guidance on the performance of nondestructive evaluation (NDE) so that operators will know what type of NDE to perform and where to perform NDE within the boiler. The use of appropriate NDE methods is an essential approach to detecting and mitigating boi...

2007-08-30T23:59:59.000Z

139

Weighted Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Weighted Guidelines Weighted Guidelines Weighted Guidelines More Documents & Publications Weighted Guidelines DOE F 4220.23 OPAM Policy Acquisition Guides...

140

Weighted Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Weighted Guidelines Weighted Guidelines Weighted Guidelines More Documents & Publications Weighted Guidelines OPAM Policy Acquisition Guides DOE F 4220.23...

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Low Energy Office: Design and Evaluation  

E-Print Network (OSTI)

The new government building with ca. 14.000 m2 gross floor area in Innsbruck/Tirol was designed as a low energy office building. As little technical installations as possible and as much room comfort as achievable: These were the two goals, set by the builder and user. An interdisciplinary team of architects, HVAC-planners and energy designers had already developed an integrated concept for the architectural competition. This was altered and adapted during the realization phase of the building. Detailed building simulations were used to determine the interactions of building, climate and users. The integration of three glass atria into the concept, unheated and naturally ventilated, was one of the main challenges in this planning process. These atria serve as thermal buffers and use the passive gains of solar energy. Only the internal areas are ventilated mechanically. The facades were optimized to combine daylighting and protection against high solar irradiation. Reduction of the cooling load, night ventilation of the atria and groundwater cooling in the offices secure moderate temperatures without any mechanical cooling. Despite a dense utilization the building offers attractive workplaces with a comfortable room climate. The energy consumption for heating in the first fully measured year was 35 kWh/m2, which is very close to the prediction. The consumption of primary energy is low also. The measured atria air temperatures comply in general with the simulated ones. A direct comparison of simulation and measurement is planned for the future.

Schrag, T.; Waldhoff, C.; Radler, J.; Lenzen, B.

2008-10-01T23:59:59.000Z

142

Evaluation of connection types in design for disassembly (DFD) using analytic network process  

Science Conference Proceedings (OSTI)

Design for disassembly (DFD) is an important design concept to make products more friendly for maintenance and remanufacturing practices. One of the important issues in DFD guidelines is related with the selection of the connectors used in the product. ... Keywords: ANP, Connectors, Design for disassembly, Disassembly, Environment

A?k?ner Güngör

2006-05-01T23:59:59.000Z

143

The design and evaluation of an international plutonium storage system  

E-Print Network (OSTI)

To address the proliferation risk of separated plutonium, a technical and institutional design of an international plutonium storage system (IPSS) is presented. The IPSS is evaluated from two perspectives: its ability to ...

Bae, Eugene

2001-01-01T23:59:59.000Z

144

Measure Guideline: Evaporative Condensers  

SciTech Connect

The purpose of this measure guideline on evaporative condensers is to provide information on a cost-effective solution for energy and demand savings in homes with cooling loads. This is a prescriptive approach that outlines selection criteria, design and installation procedures, and operation and maintenance best practices. This document has been prepared to provide a process for properly designing, installing, and maintaining evaporative condenser systems as well as understanding the benefits, costs, and tradeoffs.

German, A.; Dakin, B.; Hoeschele, M.

2012-03-01T23:59:59.000Z

145

Design and evaluation of small water turbines. Final report  

Science Conference Proceedings (OSTI)

An evaluation was made of the design and hydromechanical performance characteristics for three basic turbine types: axial flow (Jonval), inward radial flow (Francis) and crossflow (Banki). A single commercially available turbine representative of each type and within the appropriate power range (microhydro designs to their full performance potential.

Marquis, J.A.

1983-02-17T23:59:59.000Z

146

Measure Guideline: Basement Insulation Basics  

SciTech Connect

This guideline is intended to describe good practices for insulating basements in new and existing homes, and is intended to be a practical resources for building contractors, designers, and also to homeowners.

Aldrich, R.; Mantha, P.; Puttagunta, S.

2012-10-01T23:59:59.000Z

147

Brand Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

july 2012 molecular foundry brand guidelines Vision Our vision defines why we are here. We're here to provide support to researchers from around the world whose work can benefit from or contribute to nanoscience. Mission Our mission is the support that holds up our vision. Through unparalleled access to state-of-the-art instruments, materials, technical expertise, and training, the Molecular Foundry provides researchers with the tools to enhance the development and understanding of the synthesis, characterization, and theory of nanoscale materials. Values Our values are what we believe in. They define our success. People / Research / Collaboration / Enthusiasm Signature molecular foundry brand guidelines Signature :: 5 Signature :: Introduction The Molecular Foundry signature consists of the logotype in a fixed

148

The monitoring, evaluation, reporting, and verification of climate change mitigation projects: Discussion of issues and methodologies and review of existing protocols and guidelines  

Science Conference Proceedings (OSTI)

Because of concerns with the growing threat of global climate change from increasing emissions of greenhouse gases, the US and other countries are implementing, by themselves or in cooperation with one or more other nations (i.e., joint implementation), climate change mitigation projects. These projects will reduce greenhouse gas (GHG) emissions or sequester carbon, and will also result in non-GHG impacts (i.e., environmental, economic, and social impacts). Monitoring, evaluating, reporting, and verifying (MERV) guidelines are needed for these projects in order to accurately determine their net GHG, and other, benefits. Implementation of MERV guidelines is also intended to: (1) increase the reliability of data for estimating GHG benefits; (2) provide real-time data so that mid-course corrections can be made; (3) introduce consistency and transparency across project types and reporters; and (4) enhance the credibility of the projects with stakeholders. In this paper, the authors review the issues and methodologies involved in MERV activities. In addition, they review protocols and guidelines that have been developed for MERV of GHG emissions in the energy and non-energy sectors by governments, nongovernmental organizations, and international agencies. They comment on their relevance and completeness, and identify several topics that future protocols and guidelines need to address, such as (1) establishing a credible baseline; (2) accounting for impacts outside project boundaries through leakage; (3) net GHG reductions and other impacts; (4) precision of measurement; (5) MERV frequency; (6) persistence (sustainability) of savings, emissions reduction, and carbon sequestration; (7) reporting by multiple project participants; (8) verification of GHG reduction credits; (9) uncertainty and risk; (10) institutional capacity in conducting MERV; and (11) the cost of MERV.

Vine, E.; Sathaye, J.

1997-12-01T23:59:59.000Z

149

Roof and Attic Design Guidelines for new and retrofit Construction of Homes in Hot and Coild Climates  

SciTech Connect

Some guidelines for improving the energy efficiency of roofs and attics are presented and are based on the research of the DOE Building Technology. The results of combined analytical and experimental studies were used to benchmark computer tools, which in turn, were used to simulate homes in hot and cold climates. Adding floor and roof insulation, above deck ventilation, radiant barriers, cool color shingle, metal or tile roofs, sealing the attic floor, sealing the duct system and sealing the attic were simulated to compute the cost of energy savings. Results are prioritized to help building owners make an informed economic decision when contemplating roof and attic retrofits. Sealing the attic floor is a top retrofit option. The sealed attic approach and a new prototype roof assembly an insulated and ventilated roof are good options for retrofit work but have paybacks ranging from 15 to 25 years. A new sealed attic concept was simulated and computations show its simple payback is about 10 to 12 years in hot and cold climates; its first cost is significantly reduced from that of a spray foam approach. For new construction the best option is to keep the ducts out of the attic, make sure the attic floor is sealed and add at least code level of insulation to the ceiling.

Desjarlais, Andre Omer [ORNL] [ORNL; LaFrance, Marc [International Energy Agency] [International Energy Agency

2013-01-01T23:59:59.000Z

150

Evaluation of Generic EBS Design Concepts and Process Models Implications  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Generic EBS Design Concepts and Process Models Generic EBS Design Concepts and Process Models Implications to EBS Design Optimization Evaluation of Generic EBS Design Concepts and Process Models Implications to EBS Design Optimization The assessment of generic Engineered Barrier System (EBS) concepts and design optimization to harbor various disposal configurations and waste types needs advanced approaches and methods to analyze barrier performance. The report addresses: 1) Overview of the importance of Thermal-Hydrological-Mechanical-Chemical (THMC) processes to barrier performance, and international collaborations; 2) THMC processes in clay barriers; 3) experimental studies of clay stability and clay-metal interactions at high temperatures and pressures; 4) thermodynamic modeling and database development; 5) Molecular Dynamics (MD) study of clay

151

Design Tools for Evaluating Alternative Strategies' Impact on Human Comfort  

E-Print Network (OSTI)

Many designers recognize that energy savings can be achieved with alternative or innovative strategies; however, few design tools have been available to assist designers with evaluating alternatives. This paper demonstrates the use of a standard psychrometric chart enhanced with an expanded comfort zone plot based on multiple energy conservation strategies. Average local weather conditions can be plotted by month on the psychrometric chart to indicate which design alternatives have the greatest potential benefits. By utilizing a familiar engineering design tool to communicate integrated design techniques, better coordination can be achieved between architects and engineers. Victor Olgyay pioneered similar work at Notre Dame in the 1950's; however, his unusual graphical presentation has hindered widespread understanding and use of the fundamentals of expanded comfort zones. This paper outlines the basic concept of the expanded comfort zone with applications for use of mean radiant temperatures, direct radiation. air movement and evaporative cooling with examples shown for Dallas and Houston climates.

Holder, L. M. III; Hart, M. N.

1985-01-01T23:59:59.000Z

152

Human Factors Guidance for Control Room and Digital Human-System Interface Design and Modification, Guidelines for Planning, Specification, Design, Licensing, Implementation, Training, Operation and Maintenance  

Science Conference Proceedings (OSTI)

Nuclear plant operators face a significant challenge designing and modifying control rooms. This report provides guidance on planning, designing, implementing and operating modernized control rooms and digital human-system interfaces.

R. Fink, D. Hill, J. O'Hara

2004-11-30T23:59:59.000Z

153

Design, construction and evaluation of a simulated geothermal flow system  

Science Conference Proceedings (OSTI)

A system was designed and built to simulate the flow from a geothermal well. The simulated flow will be used to power a Lysholm engine, the performance of which will then be evaluated for different simulated geothermal flows. Two main subjects are covered: 1) the design, construction and evaluation of the behavior of the system that simulates the geothermal flow; included in that topic is a discussion of the probable behavior of the Lysholm engine when it is put into operation, and 2) the investigation of the use of dynamic modeling techniques to determine whether they can provide a suitable means for predicting the behavior of the system.

Mackanic, J.C.

1980-07-28T23:59:59.000Z

154

TORIS Data Preparation Guidelines  

SciTech Connect

The objective of this manual is to present guidelines and procedures for the preparation of new data for the Tertiary Oil Recovery Information System (TORIS) data base. TORIS is an analytical system currently maintained by the Department of Energy's (DOE) Bartlesville Project Office. It uses an extensive field- and reservoir-level data base to evaluate the technical and economic recovery potential of specific crude oil reservoirs.

Guinn, H.; Remson, D.

1999-03-11T23:59:59.000Z

155

Biomass Cofiring Guidelines  

Science Conference Proceedings (OSTI)

Biomass, primarily wood waste such as sawdust, has been cofired in over twenty utility coal-fired boilers in the United States at cofiring levels where the biomass provides from 1% to 10% of the heat input to the boiler. These guidelines present insights and conclusions from five years of EPRI assessment and testing of biomass cofiring and will enable utility engineers and power plant managers to evaluate their own options and plan their own tests.

1997-10-09T23:59:59.000Z

156

DOE natural phenomenal hazards design and evaluation criteria  

Science Conference Proceedings (OSTI)

It is the policy of the Department of Energy (DOE) to design, construct, and operate DOE facilities so that workers, the general public, and the environment are protected from the impacts of natural phenomena hazards (NPH). Furthermore, DOE has established explicit goals of acceptable risk for NPH performance. As a result, natural phenomena hazard (earthquake, extreme wind, and flood) design and evaluation criteria for DOE facilities have been developed based on target probabilistic performance goals. These criteria include selection of design/evaluation NPH input from probabilistic hazard curves combined with commonly practiced deterministic response evaluation methods and acceptance criteria with controlled levels of conservatism. For earthquake considerations, conservatism is intentionally introduced in specification of material strengths and capacities, in the allowance of limited inelastic behavior, and by a seismic scale factor. Criteria have been developed following a graded approach for several performance goals ranging from that appropriate for normal-use facilities to that appropriate for facilities involving hazardous or critical operations. Performance goals are comprised of qualitative expressions of acceptable behavior and of target quantitative probabilities that acceptable limits of behavior are maintained. The criteria are simple procedures but have a rigorous basis. This paper addresses DOE seismic design and evaluation criteria.

Murray, R.C.; Nelson, T.A. [Lawrence Livermore National Lab., CA (United States); Short, S.A. [EQE International, Inc., Irvine, CA (United States); Kennedy, R.P.; Chander, H. [RPK Structural Mechanics Consulting, Inc., Yorba Linda, CA (United States); Hill, J.R.; Kimball, J.K. [USDOE, Washington, DC (United States)

1994-10-01T23:59:59.000Z

157

Weighted Guidelines  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

───────────────────────────────────Chapter 15.4-2 (July 2010) 1 Weighted Guidelines [References: FAR 15.4, DEAR 915.4] Overview This section provides guidance for applying the Department of Energy's (DOE) structured approach in determining profit/fee. Background The Federal Acquisition Regulation (FAR) requires consideration of certain factors (described in 15.404-4 as "profit-analysis factors" or "common factors") in developing a structured profit/fee approach. It does not prescribe specific government-wide procedures for profit/fee analysis. Actual profit/fee may vary (FAR 15.404-4(a) (1)) as you perform your profit/fee analysis;

158

Rapid Risk-Based Evaluation of Competing Conceptual Designs  

SciTech Connect

In this paper, the authors have shown how a qualitative analysis can provide good input to a risk reduction design problem. Traditionally qualitative analyses such as the FMEA can be supplemented by qualitative fault trees and event trees to produce logic models of the accident sequences for the different design options. These models can be compared using rule-based manipulations of qualitative branch point probabilities. A qualitative evaluation of other considerations such as collateral safety effects, operational impacts and worker-safety impacts can provide a more complete picture of the trade-off between options. The authors believe that their risk-reduction analysis approach that combines logic models with qualitative and possibility metrics provides an excellent tool for incorporating safety concerns rapidly and effectively into a conceptual design evaluation.

Bott, T.F.; Butner, J.M.

1999-08-22T23:59:59.000Z

159

Steam Generator Integrity Assessment Guidelines  

Science Conference Proceedings (OSTI)

This report provides guidance for evaluating the condition of steam generator (SG) tubes based on nondestructive examination (NDE) or in situ pressure testing. This integrity assessment is normally performed during a reactor refueling outage. Nuclear power plant licensees who follow this document's guidelines will have satisfied their requirements for condition monitoring and operational assessment as defined in the Nuclear Energy Institute (NEI) initiative, Steam Generator Program Guidelines, NEI 97-06.

2006-07-25T23:59:59.000Z

160

Evaluation and design of double-skin facades for office buildings in hot climates  

E-Print Network (OSTI)

The main objectives of this research are (a) to investigate the thermal effect of double skin facades in office buildings in hot climates and (b) to propose guidelines for their efficient design based on this evaluation. The study involves the energy performance analysis of two buildings in India. A base case with the existing building skin was simulated for both the cities. The main source for the high cooling loads was found to be heat gain through windows and walls. This led to the evolution of a series of facade strategies with the goals of reducing heat gain, providing ventilation and day-lighting. The buildings were then simulated for their energy performance with the proposed double-skin strategies. Each of these strategies was varied according to the layers constituting the facade, the transparency of the facade and the orientation of the facade to which it is applied. Final comparisons of energy consumption were made between the proposed options and the base case to find the most efficient strategy and also the factors that affected this efficiency. The simulations were done using the building simulation software, Ener-Win. The double skin was simulated as per an approximate and simplistic calculation of the u-value, solar heat gain coefficient and transmissivity properties of the layers constituting the facade. The model relied on logically arrived at assumptions about the facade properties that were approximately within 10% range of measured values. Based on inferences drawn from these simulations, a set of design guidelines comprised of goals and parameters was generated for design of double-skin facades in hot climates typical to most of the Indian subcontinent. It was realized that the double-skin defined typically as a 'pair of glass skins separated by an air corridor' may not be an entirely energy efficient design strategy for hot climates. However, when used appropriately in combination with other materials, in the right orientation and with the right transparency, a double-layered facade turns out to be an energy efficient solution.

Yellamraju, Vijaya

2003-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Dietary guidelines report released  

Science Conference Proceedings (OSTI)

The Report of the Dietary Guidelines Advisory Committee on the Dietary Guidelines for Americans 2010 was released in June by the US Departments of Agriculture and Health and Human Services. Dietary guidelines report released Health Nutrition Tran

162

Total quality management implementation guidelines  

SciTech Connect

These Guidelines were designed by the Energy Quality Council to help managers and supervisors in the Department of Energy Complex bring Total Quality Management to their organizations. Because the Department is composed of a rich mixture of diverse organizations, each with its own distinctive culture and quality history, these Guidelines are intended to be adapted by users to meet the particular needs of their organizations. For example, for organizations that are well along on their quality journeys and may already have achieved quality results, these Guidelines will provide a consistent methodology and terminology reference to foster their alignment with the overall Energy quality initiative. For organizations that are just beginning their quality journeys, these Guidelines will serve as a startup manual on quality principles applied in the Energy context.

Not Available

1993-12-01T23:59:59.000Z

163

Design and Evaluation of Ionic Liquids as Novel Absorbents  

NLE Websites -- All DOE Office Websites (Extended Search)

Design anD evaluation of ionic liquiDs Design anD evaluation of ionic liquiDs as novel absorbents Background There is growing concern among climate scientists that the buildup of greenhouse gases (GHG), particularly carbon dioxide (CO 2 ), in the atmosphere is affecting the global climate in ways that could have serious consequences. One approach to reducing GHG emissions is to scrub CO 2 from the flue gas of power plants and sequester it in geologic formations. Although it is technically feasible to remove CO 2 from flue gas, current processes are too expensive. New, less expensive processes are needed. This project is investigating the feasibility of using a novel class of compounds - ionic liquids - for the capture of CO 2 from the flue gas from coal and natural gas-fired power plants. The success of ionic liquids technology

164

DOE-STD-3007-93 CN-1; DOE Standard Guidelines For Preparing Criticality Safety Evaluations at Department of Energy Non-Reactor Nuclear Facilities  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7-93 7-93 November 1993 CHANGE NOTICE NO. 1 September 1998 DOE STANDARD GUIDELINES FOR PREPARING CRITICALITY SAFETY EVALUATIONS AT DEPARTMENT OF ENERGY NON-REACTOR NUCLEAR FACILITIES U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 605-6000. Order No. DE98003918 Change Notice No. 1 DOE-STD-3007-93 September 1998

165

Design and Evaluation of Daylighting Applications of Holographic Glazings  

NLE Websites -- All DOE Office Websites (Extended Search)

Design and Evaluation of Daylighting Applications of Holographic Glazings Design and Evaluation of Daylighting Applications of Holographic Glazings Title Design and Evaluation of Daylighting Applications of Holographic Glazings Publication Type Report LBNL Report Number LBNL-44167 Year of Publication 1996 Authors Papamichael, Konstantinos M., Charles K. Ehrlich, and Gregory J. Ward Call Number LBNL-44167 Abstract When combined with appropriate electric lighting dimming controls, the use of daylight for ambient and task illumination can significantly reduce energy requirements in commercial buildings. While skylights can effectively illuminate any part of one-story buildings, conventional side windows can illuminate only a 15 ft - 20 ft (4.6 m - 6.1 m) depth of the building perimeter. Even so, the overall efficacy of daylight is limited, because side windows produce uneven distributions of daylight. Achieving adequate illumination at distances further away from the window results in excessive illumination near the window, which increases cooling loads from the associated solar heat gain. As a result, the use of larger apertures and/or higher transmittance glazings, to introduce daylight deeper than 15 ft - 20 ft (4.6 m - 6.1 m), may prove ineffective with respect to saving energy, because cooling load penalties may exceed the electric lighting savings.

166

Design and evaluation of small water turbines. Final report  

DOE Green Energy (OSTI)

An evaluation was made of the design and hydromechanical performance characteristics for three basic turbine types: axial flow (Jonval), inward radial flow (Francis) and crossflow (Banki). A single commercially available turbine representative of each type and within the appropriate power range (<5hp) was obtained for evaluation. Specific turbine selections were based on price, availability and suitability for operation at heads of 50 feet or less and flows under 2 cubic feet per second. In general, the peak operating efficiencies of each unit tended to be lower than anticipated, falling in the range of 40 to 50%. With sufficient flow, however, significant useful power outputs up to 3 hp were obtained. While the radial flow turbine (a centrifugal pump operated as a turbine) had the lowest initial unit cost, the axial and cross flow designs exhibited more stable operation, particularly under transient loadings. The crossflow turbine had the added advantage that it was essentially self-cleaning. With further developmental effort and appropriate design modifications it should be possible to bring each of these microhydro designs to their full performance potential.

Marquis, J.A.

1983-02-17T23:59:59.000Z

167

Procedural Guideline for Evaluating Alternative Fish Protection Technologies to Meet Section 316(b) Requirements of the Clean Water Act  

Science Conference Proceedings (OSTI)

As part of an effort to develop implementation rules for Section 316(b) of the Clean Water Act (CWA), EPRI commissioned this effort. The goal is to create a technically and biologically defensible screening process for evaluating and identifying alternative fish protection technologies that merit more rigorous evaluation.

2000-12-05T23:59:59.000Z

168

Technical Guidelines Development Committee  

Science Conference Proceedings (OSTI)

TECHNICAL GUIDELINES DEVELOPMENT COMMITTEE (TGDC). The TGDC has been chartered by the US Election Assistance ...

2012-11-07T23:59:59.000Z

169

BWRVIP-41, Revision 3: BWR Vessel and Internals Project, BWR Jet Pump Assembly Inspection and Flaw Evaluation Guidelines  

Science Conference Proceedings (OSTI)

The Boiling Water Reactor Vessel and Internals Project (BWRVIP), formed in June 1994, is an association of utilities focused exclusively on BWR vessel and internals issues. This BWRVIP report provides information on potential failure locations in BWR/3-6 jet pump components and recommends an inspection program designed to ensure that the integrity of all jet pump safety functions is maintained. EPRI published a previous version of this report as BWRVIP-41, Revision 2 (EPRI 1019570). This report (EPRI Rep...

2010-09-10T23:59:59.000Z

170

Evolution of web site design patterns  

Science Conference Proceedings (OSTI)

The Web enables broad dissemination of information and services; however, the ways in which sites are designed can either facilitate or impede users' benefit from these resources. We present a longitudinal study of web site design from 2000 to 2003. ... Keywords: World Wide Web, accessibility, automated usability evaluation, design guidelines, empirical studies, usability, web site design

Melody Y. Ivory; Rodrick Megraw

2005-10-01T23:59:59.000Z

171

A design tool architecture for the rapid evaluation of product design tradeoffs in an Inernet-based system modeling environment  

E-Print Network (OSTI)

This thesis presents a computer-aided design tool for the rapid evaluation of design tradeoffs in an integrated product modeling environment. The goal of this work is to provide product development organizations with better ...

Wronski, Jacob (Jacob Andrzej)

2005-01-01T23:59:59.000Z

172

Formalising medical quality indicators to improve guidelines  

E-Print Network (OSTI)

Formalising medical quality indicators to improve guidelines Marjolein van Gendt, Annette ten Teije,annette,rserban,frank.van.harmelen}@cs.vu.nl Abstract. Medical guidelines can significantly improve quality of med- ical care and reduce costs. But how that are formulated by medical institutions to evaluate medical care. The main research questions are (i) whether

ten Teije, Annette

173

Formalising medical quality indicators to improve guidelines  

E-Print Network (OSTI)

Formalising medical quality indicators to improve guidelines Marjolein van Gendt1 , Annette ten,annette,rserban,frank.van.harmelen}@cs.vu.nl Abstract. Medical guidelines can significantly improve quality of med- ical care and reduce costs. But how that are formulated by medical institutions to evaluate medical care. The main research questions are (i) whether

van Harmelen, Frank

174

Emergency Response Guideline Development  

SciTech Connect

Task 5 of the collaborative effort between ORNL, Brazil, and Westinghouse for the International Nuclear Energy Research Initiative entitled “Development of Advanced Instrumentation and Control for an Integrated Primary System Reactor” focuses on operator control and protection system interaction, with particular emphasis on developing emergency response guidelines (ERGs). As in the earlier tasks, we will use the IRIS plant as a specific example of an integrated primary system reactor (IPSR) design. The present state of the IRIS plant design – specifically, the lack of a detailed secondary system design – precludes establishing detailed emergency procedures at this time. However, we can create a structure for their eventual development. This report summarizes our progress to date. Section 1.2 describes the scope of this effort. Section 2 compares IPSR ERG development to the recent AP1000 effort, and identifies three key plant differences that affect the ERGs and control room designs. The next three sections investigate these differences in more detail. Section 3 reviews the IRIS Safety-by-Design™ philosophy and its impact on the ERGs. Section 4 looks at differences between the IRIS and traditional loop PWR I&C Systems, and considers their implications for both control room design and ERG development. Section 5 examines the implications of having one operating staff control multiple reactor units. Section 6 provides sample IRIS emergency operating procedures (EOPs). Section 7 summarizes our conclusions.

Gary D. Storrick

2007-09-30T23:59:59.000Z

175

An evaluation of the bioclimatic chart for choosing design strategies for a thermostatically-controlled residence in selected climates  

E-Print Network (OSTI)

To be successful in sustainable building design, architects must consider energy efficient design strategies in the early design stage. Unfortunately, many architects still rely on simplified analysis, synthesis techniques, and historical examples. Although, building energy simulations are becoming more common in the design of buildings, architects rarely use simulation in the early design stage. The "Bioclimatic" charts have been used in the early design stage to define potential building design strategies to achieve indoor thermal comfort. Currently, many architects use the Givoni-Milne bioclimatic design chart (Milne and Givoni, 1979), which was developed based on principle reasoning and heuristics. There have been many attempts to develop computerized programs to further the bioclimatic analysis; however, there have been very limited efforts to test and evaluate the design strategies of the chart using simulations of a thermostatically-controlled building. Therefore, the purpose of this research is to promote comfortable buildings that reduce energy use through appropriate building design strategies. The objectives of the research are to develop a more accurate bioclimatic chart for a thermostaticallycontrolled residence by testing and evaluating the Givoni-Milne bioclimatic chart. The analysis is performed with DOE-2.1e program (Winkelmann, 1993) and TMY2 weather data (Marion and Urban, 1995) for several climates. To achieve these objectives, four main tasks were accomplished: 1) investigate the Givoni-Milne Bioclimatic Chart using representative weather data from several climates, 2) analyze and modify the design strategy boundaries using DOE-2 program and TMY2 weather data to simulate the effects of varied conditions of a thermostatically-controlled residence in different climates, 3) compare these new design strategy boundaries to the original Givoni-Milne design strategy boundaries, and 4) develop general guidelines for the new bioclimatic chart. In summary, there were some differences in the results from the Givoni-Milne bioclimatic chart and the DOE-2 simulation results. These results imply that without further modification, the G-M Chart may have only a limited use for a thermostaticallycontrolled residence. Therefore, to improve the usefulness of the bioclimatic chart the new bio-climatic chart for choosing design strategies for a thermostatically-controlled residence in the hot-humid climate of Houston, Texas, was developed. This new bioclimatic chart for a thermostatically-controlled residence will be a useful tool for architects and engineers in the early design stage. Similar versions of the new bioclimatic for other climates could then be developed.

Visitsak, Sopa

2007-12-01T23:59:59.000Z

176

An Evaluation of the Bioclimatic Chart for Choosing Design Strategies for a Thermostatically-controlled Residence in Selected Climates  

E-Print Network (OSTI)

To be successful in sustainable building design, architects must consider energy efficient design strategies in the early design stage. Unfortunately, many architects still rely on simplified analysis, synthesis techniques, and historical examples. Although, building energy simulations are becoming more common in the design of buildings, architects rarely use simulation in the early design stage. The “Bioclimatic” charts have been used in the early design stage to define potential building design strategies to achieve indoor thermal comfort. Currently, many architects use the Givoni-Milne bioclimatic design chart (Milne and Givoni, 1979), which was developed based on principle reasoning and heuristics. There have been many attempts to develop computerized programs to further the bioclimatic analysis; however, there have been very limited efforts to test and evaluate the design strategies of the chart using simulations of a thermostatically-controlled building. Therefore, the purpose of this research is to promote comfortable buildings that reduce energy use through appropriate building design strategies. The objectives of the research are to develop a more accurate bioclimatic chart for a thermostaticallycontrolled residence by testing and evaluating the Givoni-Milne bioclimatic chart. The analysis is performed with DOE-2.1e program (Winkelmann, 1993) and TMY2 weather data (Marion and Urban, 1995) for several climates. To achieve these objectives, four main tasks were accomplished: 1) investigate the Givoni-Milne Bioclimatic Chart using representative weather data from several climates, 2) analyze and modify the design strategy boundaries using DOE-2 program and TMY2 weather data to simulate the effects of varied conditions of a thermostatically-controlled residence in different climates, 3) compare these new design strategy boundaries to the original Givoni-Milne design strategy boundaries, and 4) develop general guidelines for the new bioclimatic chart. In summary, there were some differences in the results from the Givoni-Milne bioclimatic chart and the DOE-2 simulation results. These results imply that without further modification, the G-M Chart may have only a limited use for a thermostaticallycontrolled residence. Therefore, to improve the usefulness of the bioclimatic chart the new bio-climatic chart for choosing design strategies for a thermostatically-controlled residence in the hot-humid climate of Houston, Texas, was developed. This new bioclimatic chart for a thermostatically-controlled residence will be a useful tool for architects and engineers in the early design stage. Similar versions of the new bioclimatic for other climates could then be developed.

Visitsak, Sopa

2007-12-01T23:59:59.000Z

177

An evaluation of the bioclimatic chart for choosing design strategies for a thermostatically-controlled residence in selected climates  

E-Print Network (OSTI)

To be successful in sustainable building design, architects must consider energy efficient design strategies in the early design stage. Unfortunately, many architects still rely on simplified analysis, synthesis techniques, and historical examples. Although, building energy simulations are becoming more common in the design of buildings, architects rarely use simulation in the early design stage. The “Bioclimatic” charts have been used in the early design stage to define potential building design strategies to achieve indoor thermal comfort. Currently, many architects use the Givoni-Milne bioclimatic design chart (Milne and Givoni, 1979), which was developed based on principle reasoning and heuristics. There have been many attempts to develop computerized programs to further the bioclimatic analysis; however, there have been very limited efforts to test and evaluate the design strategies of the chart using simulations of a thermostatically-controlled building. Therefore, the purpose of this research is to promote comfortable buildings that reduce energy use through appropriate building design strategies. The objectives of the research are to develop a more accurate bioclimatic chart for a thermostaticallycontrolled residence by testing and evaluating the Givoni-Milne bioclimatic chart. The analysis is performed with DOE-2.1e program (Winkelmann, 1993) and TMY2 weather data (Marion and Urban, 1995) for several climates. To achieve these objectives, four main tasks were accomplished: 1) investigate the Givoni-Milne Bioclimatic Chart using representative weather data from several climates, 2) analyze and modify the design strategy boundaries using DOE-2 program and TMY2 weather data to simulate the effects of varied conditions of a thermostatically-controlled residence in different climates, 3) compare these new design strategy boundaries to the original Givoni-Milne design strategy boundaries, and 4) develop general guidelines for the new bioclimatic chart. In summary, there were some differences in the results from the Givoni-Milne bioclimatic chart and the DOE-2 simulation results. These results imply that without further modification, the G-M Chart may have only a limited use for a thermostaticallycontrolled residence. Therefore, to improve the usefulness of the bioclimatic chart the new bio-climatic chart for choosing design strategies for a thermostatically-controlled residence in the hot-humid climate of Houston, Texas, was developed. This new bioclimatic chart for a thermostatically-controlled residence will be a useful tool for architects and engineers in the early design stage. Similar versions of the new bioclimatic for other climates could then be developed.

Visitsak, Sopa

2007-12-01T23:59:59.000Z

178

Boiler Condition Assessment Guideline  

Science Conference Proceedings (OSTI)

This report Boiler Condition Assessment Guideline provides a concise overview of procedures developed by the Electric Power Research Institute EPRI to help power plant operators cost-effectively determine the extent of degradation and remaining life of key boiler components. The Guideline draws from EPRIs detailed area-specific guidelines, which in turn are based on extensive research findings by EPRI, member companies, and other organizations. This Guideline offers a starting point for power plant perso...

2010-12-23T23:59:59.000Z

179

Student Task Modeling in Design and Evaluation of Open Problem-Solving Environments  

Science Conference Proceedings (OSTI)

Design and evaluation of computer-based open problem solving environments is a non-trivial task. Definition of a design framework, which involves a strong field-evaluation phase, has been the subject of the research described in this paper. This framework ... Keywords: open problem solving educational environments, student task model, task analysis, usability evaluation, user interface design

Nikolaos K. Tselios; Nikolaos M. Avouris; Maria Kordaki

2002-03-01T23:59:59.000Z

180

Some Internet Architectural Guidelines and Philosophy  

Science Conference Proceedings (OSTI)

This document extends RFC 1958 by outlining some of the philosophical guidelines to which architects and designers of Internet backbone networks should adhere. We describe the Simplicity Principle, which states that complexity is the primary mechanism ...

R. Bush; D. Meyer

2002-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Job Counting Guidelines  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Environmental Management Environmental Management Definitions and Guidelines for Counting Monthly and Quarterly EM Recovery Act Full Time Equivalents (FTEs) and Cumulative Head-Count The following updated definitions and guidelines are intended to provide EM Recovery Act sites with information to collect and report timely and accurate full-time equivalent and cumulative head-count data for both monthly and quarterly jobs data calls. These revised guidelines supersede the previous monthly jobs data reporting definitions and guidelines dated February 9, 2010. These revised guidelines remain consistent with OMB guidance issued December 18, 2009 and cover subcontractors and vendors as well as prime

182

DEVELOPMENT OF A SUPPLEMENTAL RESIDUAL CONTAMINATION GUIDELINE  

Office of Legacy Management (LM)

DEVELOPMENT OF A SUPPLEMENTAL RESIDUAL CONTAMINATION GUIDELINE DEVELOPMENT OF A SUPPLEMENTAL RESIDUAL CONTAMINATION GUIDELINE FOR THE NFSS CENTRAL DRAINAGE DITCH DECEMBER 1986 Prepared for UNITED STATES DEPARTMENT OF ENERGY OAK RIDGE OPERATIONS OFFICE Under Contract No. DE-AC05-81OR20722 By Bechtel National, Inc. Oak Ridge, Tennessee Bechtel Job No. 14501 I 1.0 INTRODUCTION AND SUMMARY 1.1 OBJECTIVE AND SCOPE The objective of this report is to describe the methodology used for establishing a supplemental residual contamination guideline for the NFSS vicinity property known as the Central Drainage Ditch (CDD). Supplemental guidelines may exceed authorized guidelines if the resultant dose will not exceed the DOE radiation protection standard of 100 mrem/yr (Ref. 1). This evaluation is based on realistic exposure pathways that were

183

CHA Guidelines Working Group  

E-Print Network (OSTI)

The Community Health Assessment Guidelines have been updated from the original document published in 1997. The revisions reflect various published sources, as well as accumulated experience with community health assessment within the province of Manitoba. Special thanks to the members of the CHA Guidelines Working Group, composed of representatives of regional health authorities from across the province and Manitoba Health and Healthy Living staff. These guidelines are made

Jody Allan; Sonia Busca Owczar; Ingrid Botting; Maggie Campbell; Bunmi Fatoye; Bill Funk; Tannis Erickson; Sue Lockhart; Ales Morga; Deborah Malazdrewicz; Leonie Stranc

2009-01-01T23:59:59.000Z

184

License Application Guidelines  

market, and describe how the funding will be obtained. LICENSE APPLICATION GUIDELINES– 6. ... Key events that have led to your company’s current position in the

185

Fire Protection Program Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidelines Principal Orders Related Orders Technical Standards Guidance Current fire protection requirements of the Department reside in: DOE O 420.1C, "Facility Safety", 10 CFR...

186

Guidelines for Energy Efficient Schools  

E-Print Network (OSTI)

Operational experience of several schools designed with energy efficiency as a design criteria is discussed in this paper. Actual monthly energy usage and cost are provided. Annual energy cost performance ($/ft^2-yr) and energy performance (BTU/FT^2-yr) of these example case study schools with flexible mechanical and electrical systems are compared to published design performance guidelines and similar schools constructed without energy efficiency as a design criteria. The authors have conducted energy studies of more than 400 schools which serve as a comparative data base range of performance. Of the schools compared, those with the lowest operating cost and energy usage employed flexible HVAC systems which inherently provided for control of electrical demand. The resulting electrical demand profile of most of theme case study schools were relatively constant throughout the year which is uncommon to most schools. The design approach employed to achieve lowar operating costs and inherent demand control is a hybrid HVAC system with a designed mixture or balance between electric and natural gas energy sources. The summary of this paper will compare operating cost performance, energy performance, HVAC system type of the case study schools, eight schools with water source heat pumps, and other data base schools with various other types of HVAC systems. Design guidelines for energy efficient schools are presented.

McClure, J. D.; Estes, J. M.; Bicknell, K. N.; Estes, M. C.

1988-01-01T23:59:59.000Z

187

Evaluation framework for the design of an engineering model  

Science Conference Proceedings (OSTI)

According to both cybernetics and general system theory, a subject develops and uses an adequate model of a system to widen his/her knowledge about the system. Models are then the interface between a subject and a real-world system to solve ... Keywords: Cybernetics, Evaluation Criteria, Knowledge Evaluation, Model Evaluation

Walid Ben ahmed; Mounib Mekhilef; Bernard Yannou; Michel Bigand

2010-02-01T23:59:59.000Z

188

SunShot Initiative: Physics of Reliability: Evaluating Design Insights for  

NLE Websites -- All DOE Office Websites (Extended Search)

Physics of Reliability: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar to someone by E-mail Share SunShot Initiative: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar on Facebook Tweet about SunShot Initiative: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar on Twitter Bookmark SunShot Initiative: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar on Google Bookmark SunShot Initiative: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar on Delicious Rank SunShot Initiative: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar on Digg Find More places to share SunShot Initiative: Physics of

189

Evaluation of design ventilation requirements for enclosed parking facilities  

SciTech Connect

This paper proposes a new design approach to determine the ventilation requirements for enclosed parking garages. The design approach accounts for various factors that affect the indoor air quality within a parking facility, including the average CO emission rate, the average travel time, the number of cars, and the acceptable CO level within the parking garage. This paper first describes the results of a parametric analysis based on the design method that was developed. Then the design method is presented to explain how the ventilation flow rate can be determined for any enclosed parking facility. Finally, some suggestions are proposed to save fan energy for ventilating parking garages using demand ventilation control strategies.

Ayari, A.; Krarti, M.

2000-07-01T23:59:59.000Z

190

Evaluation of icing design criteria for lattice towers.  

E-Print Network (OSTI)

??Atmospheric icing is a major design factor for guyed lattice masts and transmission lines in Canada and many others countries with cold climate. Tall and… (more)

Korotkov, Oleksiy

2010-01-01T23:59:59.000Z

191

Evaluation and selection in product design for mass customization: A knowledge decision support approach  

Science Conference Proceedings (OSTI)

Mass customization has been identified as a competitive strategy by an increasing number of companies. Family-based product design is an efficient and effective means to realize sufficient product variety, while satisfying a range of customer demands ... Keywords: Customer-Driven Design, Design Evaluation, Fuzzy Clustering, Fuzzy Ranking, Knowledge Support, Mass Customization, Multicriteria Decision Making, Product Family Design, Product Platform

Xuan F. Zha; Ram D. Sriram; Wen F. Lu

2004-01-01T23:59:59.000Z

192

Heat Recovery Steam Generator Materials Selection Guideline  

Science Conference Proceedings (OSTI)

A considerable number of failures have occurred over the past decade in heat recovery steam generators (HRSGs). Many of these failures are attributed to poor design, improper operation, poor fabrication, or poor installation practices, but a number of them are attributed directly to improper material selection. In March 2004, the Electric Power Research Institute (EPRI) published the first heat recovery steam generator materials selection and repair guidelines (HRSG Material Selection and Repair Guidelin...

2010-12-19T23:59:59.000Z

193

CoalFleet IGCC Permitting Guidelines  

Science Conference Proceedings (OSTI)

This report provides guidance to owners of planned Integrated Gasification Combined Cycle (IGCC) power plants in order to assist them in permitting these advanced coal power generation facilities. The CoalFleet IGCC Permitting Guidelines summarize U.S. federal requirements for obtaining air, water, and solid waste permits for a generic IGCC facility, as described in EPRI report 1012227, the CoalFleet User Design Basis Specification (UDBS). The Guidelines present characteristics of IGCC emissions that mus...

2006-11-16T23:59:59.000Z

194

Fossil Plant Instrumentation and Control Guidelines  

Science Conference Proceedings (OSTI)

Best practices are generally accepted work practices that cost-effectively facilitate accomplishment of various tasks. Often based upon common sense and on-the-job training, best practices are usually employed where no industry standards are in place. Until now, a concise set of guidelines for best practices in control engineering has not been available to the power industry, although standards, guidelines, design principles, operating instructions, and training manuals have been published by authoritati...

2011-12-19T23:59:59.000Z

195

Advanced Lighting Guidelines: 1993 (Revision 1)  

Science Conference Proceedings (OSTI)

This series of guidelines, originally published in 1990 by the California Energy Commission, provides both technical and practical information about energy-efficient lighting equipment and design techniques. This revised version updates the 1990 information and adds four new sections on lighting controls and daylighting. EPRI's cofunding and publication of these guidelines will facilitate utility access to this information, resulting in increased lighting quality and energy efficiency.

1993-05-01T23:59:59.000Z

196

Totally green: evaluating and designing servers for lifecycle environmental impact  

Science Conference Proceedings (OSTI)

The environmental impact of servers and datacenters is an important future challenge. System architects have traditionally focused on operational energy as a proxy for designing green servers, but this ignores important environmental implications from ... Keywords: datacenter design, dematerialization, disaggregation, environmental sustainability, exergy, green computing, lifecycle impact, server architecture

Jichuan Chang; Justin Meza; Parthasarathy Ranganathan; Amip Shah; Rocky Shih; Cullen Bash

2012-04-01T23:59:59.000Z

197

DEPIVOT: A model for center-pivot design and evaluation  

Science Conference Proceedings (OSTI)

Center-pivot sprinkler irrigation became very popular. Hence, aimed at farmers advising, the simulation model DEPIVOT has been developed with the objective of design new systems or changes in systems in operation. The software consists of a simulation ... Keywords: Distribution uniformity, Hydraulics design, Runoff, Sprinkler package

M. I. ValíN; M. R. Cameira; P. R. Teodoro; L. S. Pereira

2012-09-01T23:59:59.000Z

198

Microsoft Word - PMCDP Course Curriculum Registration Guidelines...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Course Curriculum Registration Guidelines 2 Microsoft Word - PMCDP Course Curriculum Registration Guidelines 2 Microsoft Word - PMCDP Course Curriculum Registration Guidelines...

199

Postdoctoral Salary Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

Salary Guidelines Salary Guidelines Postdoctoral Salary Guidelines Point your career towards LANL: work with the best minds on the planet in an inclusive environment that is rich in intellectual vitality and opportunities for growth. Contact Email How postdoc salaries are determined Annual starting salaries - Postdoctoral Fellows (Agnew, Director's, Entrepreneurial, Metropolis) and Postdoctoral Research Associates Competitive salaries are based on the date the PhD degree requirements were completed or the degree was awarded. On the anniversary of these dates, salaries are automatically adjusted to the next higher level. In addition, the guidelines are reviewed annually for possible adjustments. Starting salaries may vary from the guidelines up to a maximum of 25% due to market

200

Guidelines for Exposure Assessment  

NLE Websites -- All DOE Office Websites (Extended Search)

Z-92/001 Z-92/001 May 1992 Guidelines for Exposure Assessment Published on May 29, 1992, Federal Register 57(104):22888-22938 These guidelines replace the previously issued final Guidelines for Estimating Exposures (September 24, 1986), Federal Register 51(185):34042-34054, and the Proposed Guidelines for Exposure-Related Measurements (December 2, 1988), Federal Register 53(232):48830- 48853. Risk Assessment Forum U.S. Environmental Protection Agency Washington, DC DISCLAIMER This document has been reviewed in accordance with U.S. Environmental Protection Agency policy and approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use. Note: This document represents the final guidelines. A number of editorial corrections have

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

UPS-Substation (TM): Evaluation, Conceptual Design and Generic Specification  

Science Conference Proceedings (OSTI)

In general terms, the UPS-Substation(TM) is an uninterruptible power supply (UPS) at the substation level. This report summarizes determining application requirements, developing conceptual designs and cost estimates, and assessing potential market size based on application.

1999-09-21T23:59:59.000Z

202

Design and Evaluation of Hybrid Fault-Detection Systems  

Science Conference Proceedings (OSTI)

As chip densities and clock rates increase, processors are becoming more susceptible to transient faults that can affect program correctness. Up to now, system designers have primarily considered hardware-only and software-only fault-detection mechanisms ...

George A. Reis; Jonathan Chang; Neil Vachharajani; Ram Rangan; David I. August; Shubhendu S. Mukherjee

2005-06-01T23:59:59.000Z

203

Guidelines for New High Reliability Fossil Plants  

Science Conference Proceedings (OSTI)

The purity of water and steam is central to ensuring fossil plant component availability and reliability. New plants should have the optimum cycle chemistry features designed in, and the guidelines provided in this report will assist owners and operators of new plants in specifying these features during the design phase.

2007-02-26T23:59:59.000Z

204

Derivation of guidelines for uranium residual radioactive material in soil at the New Brunswick Site, Middlesex County, New Jersey  

SciTech Connect

Residual radioactive material guidelines for uranium in soil were derived for the New Brunswick Site, located in Middlesex County, New Jersey. This site has been designated for remedial action under the Formerly Utilized Sites Remedial Action Program of the US Department of Energy (DOE). Residual radioactive material guidelines for individual radionuclides of concern and total uranium were derived on the basis of the requirement that the 50-year committed effective dose equivalent to a hypothetical individual who lives or works in the immediate vicinity of the New Brunswick Site should not exceed a dose of 30 mrem/yr following remedial action for the current-use and likely future-use scenarios or a dose of 100 mrem/yr for less likely future-use scenarios. The DOE residual radioactive material guideline computer code, RESRAD, was used in this evaluation; RESRAD implements the methodology described in the DOE manual for establishing residual radioactive material guidelines. The guidelines derived in this report are intended to apply to the remediation of these remaining residual radioactive materials at the site. The primary radionuclides of concern in these remaining materials are expected to be radium-226 and, to a lesser extent, natural uranium and thorium. The DOE has established generic cleanup guidelines for radium and thorium in soil; however, cleanup guidelines for other radionuclides must be derived on a site-specific basis.

Dunning, D.; Kamboj, S.; Nimmagadda, M.; Yu, C. [Argonne National Lab., IL (United States). Environmental Assessment Div.

1996-02-01T23:59:59.000Z

205

Evaluating APIs: a call for design science research  

Science Conference Proceedings (OSTI)

In a business world characterized by ecosystem-based competition, APIs are key determinants of success. However, there is very little guidance on how organizations should go about making decisions about APIs. API design must account for the needs of ... Keywords: API, kernel theory, modularity, stakeholders, strategy

Bala Iyer; George Wyner

2012-05-01T23:59:59.000Z

206

Self-configuring localization systems: Design and Experimental Evaluation  

Science Conference Proceedings (OSTI)

Embedded networked sensors promise to revolutionize the way we interact with our physical environment and require scalable, ad hoc deployable and energy-efficient node localization/positioning.This paper describes the motivation, design, implementation, ... Keywords: Location, localization, self-configuration, sensor networks

Nirupama Bulusu; John Heidemann; Deborah Estrin; Tommy Tran

2004-02-01T23:59:59.000Z

207

Guidelines for job and task analysis for DOE nuclear facilities  

Science Conference Proceedings (OSTI)

The guidelines are intended to be responsive to the need for information on methodology, procedures, content, and use of job and task analysis since the establishment of a requirement for position task analysis for Category A reactors in DOE 5480.1A, Chapter VI. The guide describes the general approach and methods currently being utilized in the nuclear industry and by several DOE contractors for the conduct of job and task analysis and applications to the development of training programs or evaluation of existing programs. In addition other applications for job and task analysis are described including: operating procedures development, personnel management, system design, communications, and human performance predictions.

Not Available

1983-06-01T23:59:59.000Z

208

Strategy Guideline: HVAC Equipment Sizing  

SciTech Connect

The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

Burdick, A.

2012-02-01T23:59:59.000Z

209

mFerio: the design and evaluation of a peer-to-peer mobile payment system  

Science Conference Proceedings (OSTI)

In this paper, we present the design and evaluation of a near-field communication-based mobile p2p payment application, called mFerio, that is designed to replace cash-based transactions. We first identify design criteria that payment systems should ... Keywords: digital wallet, mobile computing, mobile payment, near-field communication, nfc, p2p payment, user study

Rajesh Krishna Balan; Narayan Ramasubbu; Komsit Prakobphol; Nicolas Christin; Jason Hong

2009-06-01T23:59:59.000Z

210

Design and evaluation of lost circulation materials for severe environments  

DOE Green Energy (OSTI)

An independent analysis of lost circulation materials for geothermal applications has been completed using unique laboratory tools developed for the purpose. Test results of commercial materials as well as mathematical models for evaluating their performance are presented. Physical attributes that govern the performance of lost circulation materials are identified and correlated with test results. 9 refs., 27 figs., 4 tabs.

Loeppke, G.E.; Glowka, D.A.; Wright, E.K.

1988-01-01T23:59:59.000Z

211

Macintosh human interface guidelines  

Science Conference Proceedings (OSTI)

Macintosh Human Interface Guidelines describes the way to create products that optimize the interaction between people and Macintosh computers. It explains the whys and hows of the Macintosh interface in general terms and specific details. Macintosh ...

Apple Computer, Inc.

1992-01-01T23:59:59.000Z

212

EV Guideline Assessment Templates  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EV Guideline Assessment Templates EV Guideline Assessment Templates |1. Process: Organization |2. Guideline No: 1|3. Contractor: |4.Contract/project(s): | ||||| ||||| |5. Guideline Statement: Define the authorized work elements for the program. A work breakdown structure (WBS), tailored for effective internal management control, is commonly used in this process. | || |6. Documentation Required: 1) CLINs 2) WBS 3) WBS Dictionary | || || || |7. Instructions: Why this is important: The WBS represents the entire scope of work in the project, a "picture" of the work. The first level is the total system, and it continues down in successively smaller elements until it reaches the level of detail necessary for management action and control. This picture of the work is needed to facilitate traceability, ensure the

213

ARM - Submitting Proposals : Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

govField CampaignsSubmitting Proposals : Guidelines govField CampaignsSubmitting Proposals : Guidelines Schedule and Availability Preproposals now open for AMF and AAF Preproposals due 1 Feb Invited full proposals due 1 May AAF available Dec 2015 AMF1 available Apr 2016 AMF2 available early 2017 AMF3 available for guest instrumentation or intensive operational periods Forms Propose a Campaign Form Instrument Support Request (ISR) Form (Word, 89KB) Documentation Steps to Send Campaign Data to ARM Data Archive Field Campaign Guidelines (PDF, 1.1MB) Submitting Proposals : Guidelines Proposals are welcome from all members of the scientific community for conducting field campaigns and scientific research using the ARM Climate Research Facility sites at the Southern Great Plains (SGP), North Slope of Alaska (NSA), Tropical Western Pacific (TWP), one of the ARM Mobile

214

inform author guidelines  

Science Conference Proceedings (OSTI)

inform Author Guidelines Texts for publication include feature articles, commentaries, columns, meeting reports, news stories, profiles, and letters to the editor. The typical inform feature article ranges from 1000 to 1500 words. This word cou

215

Electrical safety guidelines  

SciTech Connect

The Electrical Safety Guidelines prescribes the DOE safety standards for DOE field offices or facilities involved in the use of electrical energy. It has been prepared to provide a uniform set of electrical safety standards and guidance for DOE installations in order to affect a reduction or elimination of risks associated with the use of electrical energy. The objectives of these guidelines are to enhance electrical safety awareness and mitigate electrical hazards to employees, the public, and the environment.

Not Available

1993-09-01T23:59:59.000Z

216

Outage Management Benchmarking Guideline  

Science Conference Proceedings (OSTI)

Benchmarking of power plant outages will help plants target performance improvements to specific elements of a plant outage program in order to improve overall availability, reliability, and safety while decreasing generation costs. EPRI's "Outage Management Benchmarking Guideline" builds on the Institute's fossil and nuclear plant experience with routine maintenance and extends that to outage maintenance processes. The guideline describes the initial steps in an outage benchmarking effort and 13 key ele...

2003-03-26T23:59:59.000Z

217

Updated Operations Assessment Guideline  

Science Conference Proceedings (OSTI)

The Operations Assessment Guideline (OAG) can be used to assess the organization and processes of operations departments. An internal utility team or third party can use this report to guide a team composed of industry experts and members of the assessed utility. This report is an update to EPRI report 1008520, Operations Assessment Guideline, published in March 2005. This improved version includes insights gained after three years of experience with the original report.

2008-03-25T23:59:59.000Z

218

Recommendations for Guidelines for EMF Personal Exposure Measurements, Rapid Project #4  

Science Conference Proceedings (OSTI)

The purpose of developing guidelines for electric and magnetic field (EMF) personal exposure measurements (lF'EM) is to ensure reliable and comparable data across I?EM studies. Study techniques may vary due to different populations or objectives, but the resulting data should be consistently reported and comparable, to the extent possible. Any guideline must allow creativity by the research-oriented investigator and provide specific guidance to industrial hygienists or other results-oriented investigators, requiring a standard protocol. Recognizing measurement studies with different purposes is an important aspect of these recommendations. The guidelines presented here intend to produce comparable data across studies while remaining flexible. The recommendations for designing and implementing an EMF PEM program describe a three-stage process. The first step is to clearly state the purpose of the PEM program. The next stage addresses the fundamental elements of an EMF PEM study, including an assessment of the scientific and organizational resources that will be required. This process is codified in a written study plan. These stages are described in 1 Section 5 of this report. The third stage of a PEM study involves the design, implementation and documentation of specific procedures and protocols fo~ sampling strategies, selection of measurement parameters; instrumentation, measurement and data collection, data management, data analysis, quality assurance, uncertainty evaluation, and archiving the study methods and results. The methods for designing these elements of an EMF PEM study are described in Section 6: Specific Guidelines for EMF I?EM Study Design.

T. Dan Bracken, Inc.

1997-08-01T23:59:59.000Z

219

A Report to the Secretary of Energy, Beyond Design Basis Event Pilot Evaluations  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Beyond Design Basis Event Beyond Design Basis Event Pilot Evaluations Results and Recommendations for Improvements to Enhance Nuclear Safety at Department of Energy Nuclear Facilities Office of Nuclear Safety Office of Health, Safety and Security U.S. Department of Energy January 2013 Beyond Design Basis Event Pilot Evaluations TABLE OF CONTENTS Executive Summary i Acronyms iv 1.0 Introduction and Purpose 1 2.0 Background 2 3.0 Pilot Evaluations of Safety Analysis, NPH, and Emergency Management Guidance 2 4.0 Insights Gained from NRC and the Nuclear Community 11 5.0 Summary of Results and Recommendations 12 6.0 Conclusions 14 Appendix A - Pilot Evaluation Team Members 15 Beyond Design Basis Event Pilot Evaluations * i

220

Tank exhaust comparison with 40 CFR 61.93, Subpart H, and other referenced guidelines for Tank Farms National Emission Standards for Hazardous Air Pollutant (NESHAP) designated stacks  

Science Conference Proceedings (OSTI)

The US Environmental Protection Agency (EPA) promulgated National Emission Standards other than Radon from US Department of Energy (DOE) Facilities (40 CFR 61, Subpart H) on December 15, 1989. The regulations specify procedures, equipment, and test methods that.are to be used to measure radionuclide emissions from exhaust stacks that are designated as National Emission Standards for Hazardous Air Pollutant (NESHAP) stacks. Designated NESHAP stacks are those that have the potential to cause any member of the public to receive an effective dose equivalent (EDE) greater than or equal to 0.1 mrem/year, assuming all emission controls were removed. Tank Farms currently has 33 exhaust stacks, 15 of which are designated NESHAP stacks. This document assesses the compliance status of the monitoring and sampling systems for the designated NESHAP stacks.

Bachand, D.D.; Crummel, G.M.

1994-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Gas Turbine Compressor Field Repair Guideline: GE 7FA  

Science Conference Proceedings (OSTI)

This guideline is designed to assist gas turbine owners confronted with limited damage to compressor rotating blade airfoils. The guideline addresses typical damage to the airfoil tip and leading edge where a limited amount of material trimming and blending is allowable. The guideline provides an engineering basis for implementing safe repairs and avoiding possible risk of airfoil failure due to high-cycle fatigue. In-situ field repair criteria are given for each compressor row R-0 through R-17 for ...

2012-12-03T23:59:59.000Z

222

Condensate Polishing Guidelines for PWR and BWR Plants -- 1997 Revision  

Science Conference Proceedings (OSTI)

Successful condensate polishing operations maintain control of ionic and particulate impurity transport to the PWR steam generator and the BWR reactor and recirculation system. This report presents revisions of EPRI's 1993 nuclear industry consensus guidelines for the design and operation of deep bed and filter demineralizer condensate polishers. This advice is consistent with the 1996 revisions of EPRI's BWR Water Chemistry Guidelines (TR-103515-R1) and PWR Secondary Water Chemistry Guidelines (TR-10213...

1997-10-31T23:59:59.000Z

223

Fuel Reliability Guidelines: BWR Fuel Cladding Corrosion and Crud  

Science Conference Proceedings (OSTI)

Developed in collaboration with utilities, industry organizations, and fuel vendors, a series of new EPRI guidelines capture state-of-the-art knowledge and describe best practices for eliminating fuel failures at nuclear power plants. The guidelines provide mandatory, needed, and best practice recommendations based on a thorough review of operating experience, fuel failure analyses, and fuel design and manufacturing procedures. More than 200 industry experts reviewed the guidelines to ensure accuracy and...

2008-04-01T23:59:59.000Z

224

Fuel Reliability Guidelines: PWR Fuel Cladding Corrosion and Crud  

Science Conference Proceedings (OSTI)

Developed in collaboration with utilities, industry organizations, and fuel vendors, a series of new EPRI guidelines capture state-of-the-art knowledge and describe best practices for eliminating fuel failures at nuclear power plants. The guidelines provide mandatory, needed, and best practice recommendations based on a thorough review of operating experience, fuel failure analyses, and fuel design and manufacturing procedures. More than 200 industry experts reviewed the guidelines to ensure accuracy and...

2008-04-01T23:59:59.000Z

225

Updating Human Factors Engineering Guidelines for Conducting Safety Reviews of Nuclear Power Plants  

SciTech Connect

The U.S. Nuclear Regulatory Commission (NRC) reviews the human factors engineering (HFE) programs of applicants for nuclear power plant construction permits, operating licenses, standard design certifications, and combined operating licenses. The purpose of these safety reviews is to help ensure that personnel performance and reliability are appropriately supported. Detailed design review procedures and guidance for the evaluations is provided in three key documents: the Standard Review Plan (NUREG-0800), the HFE Program Review Model (NUREG-0711), and the Human-System Interface Design Review Guidelines (NUREG-0700). These documents were last revised in 2007, 2004 and 2002, respectively. The NRC is committed to the periodic update and improvement of the guidance to ensure that it remains a state-of-the-art design evaluation tool. To this end, the NRC is updating its guidance to stay current with recent research on human performance, advances in HFE methods and tools, and new technology being employed in plant and control room design. This paper describes the role of HFE guidelines in the safety review process and the content of the key HFE guidelines used. Then we will present the methodology used to develop HFE guidance and update these documents, and describe the current status of the update program.

O, J.M.; Higgins, J.; Stephen Fleger - NRC

2011-09-19T23:59:59.000Z

226

Design, operation, and evaluation of the transportable vitrification system  

SciTech Connect

The Transportable Vitrification System (TVS) is a transportable melter system designed to demonstrate the treatment of low-level and mixed hazardous and radioactive wastes such as wastewater treatment sludges, contaminated soils and incinerator ash. The TVS is a large-scale, fully integrated vitrification system consisting of melter feed preparation, melter, offgas, service, and control modules. The TVS was tested with surrogate waste at the Clemson University Environmental Systems Engineering Department`s (ESED) DOE/Industry Center for Vitrification Research prior to being shipped to the DOE Oak Ridge Reservation (ORR) K-25 site for treatment of mixed waste. This testing, along with additional testing at ORR, proved that the TVS would be able to successfully treat mixed waste. These surrogate tests consistently produced glass that met the EPA Toxicity Characteristic Leaching Procedure (TCLP). Performance of the system resulted in acceptable emissions of regulated metals from the offgas system. The TVS is scheduled to begin mixed waste operations at ORR in June 1997.

Zamecnik, J.R.; Young, S.R.; Hansen, E.K.; Whitehouse, J.C.

1997-02-20T23:59:59.000Z

227

Design and Evaluation of an Architecture for Location Privacy  

E-Print Network (OSTI)

Many operators of cellphone networks now offer location-based services to their customers, whereby an operator often outsources service provisioning to a third-party provider. Since a person’s location could reveal sensitive information about the person, the operator must ensure that the service provider processes location information about the operator’s customers in a privacy-preserving way. We propose an architecture for location-based services based on Trusted Computing and Secure Logging. Trusted Computing lets an operator query the configuration of a location-based service. The operator will hand over location information to the service only if the service is configured such that the service provider cannot get access to location information using software-based attacks. This includes passive attacks, where the provider monitors the composition or the timing of information flowing into and out of its service, and active attacks, where the provider modifies or injects customer queries to the service. We introduce several requirements that must be satisfied by a location-based service to defend against passive attacks. Furthermore, we present Secure Logging, an auditing mechanism to defend against active attacks. We present an implementation of our architecture and demonstrate its usefulness by building two sample location-based services on top of it. The evaluation of our architecture shows that its processing delay is hardly noticeable and that timing attacks are very unlikely to succeed. 1

Urs Hengartner

2008-01-01T23:59:59.000Z

228

Evaluating winter orographic cloud seeding: Design of the Wyoming Weather Modification Pilot Project (WWMPP)  

Science Conference Proceedings (OSTI)

An overview of the Wyoming Weather Modification Pilot Project (WWMPP) is presented. This project, funded by the State of Wyoming, is designed to evaluate the effectiveness of cloud seeding with silver iodide in the Medicine Bow and Sierra Madre ...

Daniel Breed; Roy Rasmussen; Courtney Weeks; Bruce Boe; Terry Deshler

229

The Pugh Controlled Convergence Method: Model-Based Evaluation and Implications for Design Theory  

E-Print Network (OSTI)

This paper evaluates the Pugh Controlled Convergence method and its relationship to recent developments in design theory. Computer executable models are proposed simulating a team of people involved in iterated cycles of ...

Wijnia, Ype

230

Evaluating the Design of an Earth Radiation Budget Instrument with System Simulations. Part I: Instantaneous Estimates  

Science Conference Proceedings (OSTI)

A set of system simulations has been performed to evaluate candidate scanner designs for an Earth Radiation Budget Instrument (ERBI) for the Earth Observing System (EOS) of the late 1990s. Five different instruments are considered: 1) the Active ...

Larry Stowe; Philip Ardanuy; Richard Hucek; Peter Abel; Herbert Jacobowitz

1993-12-01T23:59:59.000Z

231

Guidelines Volume II  

Gasoline and Diesel Fuel Update (EIA)

II II Sector-Specific Issues and Reporting Methodologies Supporting the General Guidelines for the Voluntary Reporting of Greenhouse Gases under Section 1605(b) of the Energy Policy Act of 1992 Part 4: Transportation Sector Part 5: Forestry Sector Part 6: Agricultural Sector Transportation Sector-Page 4.iii Contents of Volume II This volume, the second of two such volumes, contains sector-specific guidance in support of the General Guidelines for the voluntary reporting of greenhouse gas emissions and carbon sequestration. This voluntary reporting program was authorized by Congress in Section 1605(b) of the Energy Policy Act of 1992. The General Guidelines, bound separately from this volume, provide the overall rationale for the program, discuss in general how to analyze emissions and emission reduction/carbon sequestration projects, and

232

Guidelines Volume I  

Gasoline and Diesel Fuel Update (EIA)

I I Sector-Specific Issues and Reporting Methodologies Supporting the General Guidelines for the Voluntary Reporting of Greenhouse Gases under Section 1605(b) of the Energy Policy Act of 1992 Part 1: Electricity Supply Sector Part 2: Residential and Commercial Buildings Sector Part 3: Industrial Sector Electricity Supply Sector-Page 1.iii Contents of Volume I This volume, the first of two such volumes, contains sector-specific guidance in support of the General Guidelines for the voluntary reporting of greenhouse gas emissions and carbon sequestration. This voluntary reporting program was authorized by Congress in Section 1605(b) of the Energy Policy Act of 1992. The General Guidelines, bound separately from this volume, provide the overall rationale for the program,

233

Natural phenomena hazards design and evaluation criteria for Department of Energy Facilities  

Science Conference Proceedings (OSTI)

This DOE standard gives design and evaluation criteria for natural phenomena hazards (NPH) effects as guidance for implementing the NPH mitigation requirements of DOE 5480.28. Goal of the criteria is to assure that DOE facilities can withstand the effects of earthquakes, extreme winds, tornadoes, flooding, etc. They apply to the design of new facilities and the evaluation of existing facilities; they may also be used for modification and upgrading of the latter.

Not Available

1994-04-01T23:59:59.000Z

234

CFO .:. Signature Authority Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

Presentations Presentations Strategic Plan Ten Commandments Budget Office Business Systems Analysis Conference Services Controller's Office Field Operations Financial Policy & Assurance Human Resources in the OCFO Procurement & Property Office of Sponsored Projects & Industry Partnerships Training Travel Office spacer OCFO Home Send Feedback Signature Authority Guidelines LBNL Signature Authority Guidelines for Operational Transactions Signature Authorization System (SAS) Database in BRS: The Authorized Signers List can be found in the BLIS Reporting System (BRS) in the purchasing folder.You will need your LDAP username and password to access this database. Access the BLIS Reporting System (BRS) by clicking HERE. Delegation of Signature Authority Form: All requests for signature authority for Laboratory employees in the

235

Strategy Guideline: Demonstration Home  

SciTech Connect

This guideline will provide a general overview of the different kinds of demonstration home projects, a basic understanding of the different roles and responsibilities involved in the successful completion of a demonstration home, and an introduction into some of the lessons learned from actual demonstration home projects. Also, this guideline will specifically look at the communication methods employed during demonstration home projects. And lastly, we will focus on how to best create a communication plan for including an energy efficient message in a demonstration home project and carry that message to successful completion.

Savage, C.; Hunt, A.

2012-12-01T23:59:59.000Z

236

Plant Engineering: Guideline for the Acceptance of Commercial-Grade Design and Analysis Computer Programs Used in Nuclear Safety-Rel ated Applications  

Science Conference Proceedings (OSTI)

This report provides methodology that can be used to perform safety classification of non-process computer programs, such as design and analysis tools, that are not resident or embedded (installed as part of) plant systems, structures, and components. The report also provides guidance for using commercial-grade dedication methodology to accept commercially procured computer programs that perform a safety-related function. The guidance is intended for use by subject matter experts in the acceptance of com...

2012-06-04T23:59:59.000Z

237

Plant Engineering: Guideline for the Acceptance of Commercial-Grade Design and Analysis Computer Programs Used in Nuclear Safety-Related Applications: Revision 1 of 1025243  

Science Conference Proceedings (OSTI)

This report supersedes EPRI 1025243 and provides methodology that can be used to perform safety classification of non-process computer programs, such as design and analysis tools, that are not resident or embedded (installed as part of) plant systems, structures, and components. The report also provides guidance for using commercial-grade dedication methodology to accept commercially procured computer programs that perform a safety-related function. The guidance is intended for use by subject matter ...

2013-12-19T23:59:59.000Z

238

Design evaluation and optimisation in multiple response nonlinear mixed effect models: PFIM 3.0  

Science Conference Proceedings (OSTI)

Nonlinear mixed effect models (NLMEM) with multiple responses are increasingly used in pharmacometrics, one of the main examples being the joint analysis of the pharmacokinetics (PK) and pharmacodynamics (PD) of a drug. Efficient tools for design evaluation ... Keywords: D-optimality, Fisher information matrix, Multiple response models, Nonlinear mixed effect models, Optimal designs, PFIM

Caroline Bazzoli; Sylvie Retout; France Mentré

2010-04-01T23:59:59.000Z

239

Design, implementation, and evaluation of EnviroMic: A storage-centric audio sensor network  

Science Conference Proceedings (OSTI)

This article presents the design, implementation, and evaluation of EnviroMic, a low-cost experimental prototype of a novel distributed acoustic monitoring, storage, and trace retrieval system designed for disconnected operation. Our intended ... Keywords: Sensor networks, acoustics, applications, distributed storage, group management

Liqian Luo; Qing Cao; Chengdu Huang; Lili Wang; Tarek F. Abdelzaher; John A. Stankovic; Michael Ward

2009-05-01T23:59:59.000Z

240

Electrostatic Precipitator Guidelines, Volumes 1-3  

Science Conference Proceedings (OSTI)

In summarizing the latest information on electrostatic precipitator technologies, these three volumes make up a central utility reference source. Plant engineers and operators will find in it detailed guidelines for preparing precipitator design specifications, for planning and conducting operations and maintenance programs, and for troubleshooting problem precipitators.

1987-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Evolution of a Visual Impact Model to Evaluate Nuclear Plant Siting and Design Option1  

E-Print Network (OSTI)

for Analysis and Management of the Visual Resource, Incline Village, Nevada, April 23-25, 1979. 2 / AssociatesEvolution of a Visual Impact Model to Evaluate Nuclear Plant Siting and Design Option1 2/ Brian A/ The method can be used to train evaluators to use explicit criteria (vividness, intactness and unity

Standiford, Richard B.

242

Natural phenomena hazards design and evaluation criteria for Department of Energy Facilities  

Science Conference Proceedings (OSTI)

The Department of Energy (DOE) has issued an Order 420.1 which establishes policy for its facilities in the event of natural phenomena hazards (NPH) along with associated NPH mitigation requirements. This DOE Standard gives design and evaluation criteria for NPH effects as guidance for implementing the NPH mitigation requirements of DOE Order 420.1 and the associated implementation Guides. These are intended to be consistent design and evaluation criteria for protection against natural phenomena hazards at DOE sites throughout the United States. The goal of these criteria is to assure that DOE facilities can withstand the effects of natural phenomena such as earthquakes, extreme winds, tornadoes, and flooding. These criteria apply to the design of new facilities and the evaluation of existing facilities. They may also be used for modification and upgrading of existing facilities as appropriate. The design and evaluation criteria presented herein control the level of conservatism introduced in the design/evaluation process such that earthquake, wind, and flood hazards are treated on a consistent basis. These criteria also employ a graded approach to ensure that the level of conservatism and rigor in design/evaluation is appropriate for facility characteristics such as importance, hazards to people on and off site, and threat to the environment. For each natural phenomena hazard covered, these criteria consist of the following: Performance Categories and target performance goals as specified in the DOE Order 420.1 NPH Implementation Guide, and DOE-STD-1 021; specified probability levels from which natural phenomena hazard loading on structures, equipment, and systems is developed; and design and evaluation procedures to evaluate response to NPH loads and criteria to assess whether or not computed response is permissible.

NONE

1996-01-01T23:59:59.000Z

243

Mixed Waste Management Guidelines  

Science Conference Proceedings (OSTI)

The management of mixed waste presents serious challenges to nuclear utilities. Regulatory and practical predicaments make compliance with the letter of all applicable regulations extremely difficult. Utility experts developed these guidelines to identify opportunities for improving work practices and regulatory compliance while minimizing any potential adverse impacts of mixed waste management.

1994-12-31T23:59:59.000Z

244

Mixed Waste Characterization Guidelines  

Science Conference Proceedings (OSTI)

This report presents an overview of the process of characterizing potential mixed waste streams from nuclear power plants. Utility experts developed these guidelines to help guide utility personnel through the characterization process and provide a mechanism for properly documenting the characterization of individual waste streams.

1995-12-31T23:59:59.000Z

245

Effectiveness Audit Guideline  

Science Conference Proceedings (OSTI)

This document is a guideline for power producers to identify how successful their organizations have been in implementing a plant maintenance optimization (PMO) program. It also shows how to determine the effectiveness of an organization's program when compared to peer power producers.

2001-11-27T23:59:59.000Z

246

The role of integral experiments and nuclear cross section evaluations in space nuclear reactor design  

SciTech Connect

The importance of the nuclear and neutronic properties of candidate space reactor materials to the design process has been acknowledged as has been the use of benchmark reactor physics experiments to verify and qualify analytical tools used in design, safety, and performance evaluation. Since June 1966, the Cross Section Evaluation Working Group (CSEWG) has acted as an interagency forum for the assessment and evaluation of nuclear reaction data used in the nuclear design process. CSEWG data testing has involved the specification and calculation of benchmark experiments which are used widely for commercial reactor design and safety analysis. These benchmark experiments preceded the issuance oflthe industry standards for acceptance, but the benchmarks exceed the minimum acceptance criteria for such data. Thus, a starting place has been provided in assuring the accuracy and uncertainty of nuclear data important to space reactor applications. (FI)

Moses, D.L.; McKnight, R.D.

1987-01-01T23:59:59.000Z

247

EV Guideline Assessment Templates | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EV Guideline Assessment Templates EV Guideline Assessment Templates DOEEVGuidelineAssessmentTemplates32.doc More Documents & Publications EV Guideline Assessment Templates...

248

EV Guideline Assessment Templates | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

EV Guideline Assessment Templates EV Guideline Assessment Templates DOEEVGuidelineAssessmentTemplates320.doc More Documents & Publications EV Guideline Assessment Templates...

249

Passive Core Decay Heat Removal Performance Guideline  

Science Conference Proceedings (OSTI)

Passive decay heat removal systems operate without pumps when normal heat removal systems are not available. Safety is ensured by confirming that an adequate thermal margin is provided to accommodate various operating conditions, design uncertainties, and degradation. Guidelines to ensure adequate thermal performance are provided for three different system configurations.This report introduces utility systems engineers to the design and operation of passive decay heat removal systems and ...

2013-11-26T23:59:59.000Z

250

Advanced Lighting Technologies Application Guidelines: 1990  

SciTech Connect

The Advanced Lighting Technologies Application Guidelines document consists of eight guidelines that provide an overview of specific lighting technologies and design application techniques utilizing energy-efficient lighting products. Lighting Design Practice assesses energy-efficient lighting strategies and explains how to obtain quality lighting design and consulting services. Luminaries and Lighting Systems surveys advanced lighting fixture products designed to take advantage of current energy-efficient lamp technologies and includes luminaire tables to allow users to collect photometric performance characteristics for common commercial luminaires. Each of the remaining six guidelines -- Computer-Aided Lighting Design, Energy-efficient and Electronic Ballasts, Full-Size Fluorescent Lamps, Compact Fluorescent Lamps, Conventional Shape Tungsten-Halogen Lamps, and Compact Metal Halide and White High Pressure Sodium Lamps -- includes a technology overview section, a description of current products available on the market, and an applications section. The document is intended for use by electric utility personnel involved in lighting programs, lighting designers, electrical engineers, architects, lighting manufacturers' representatives, and other lighting professionals.

Eley, C. (Eley (Charles) Associates, San Francisco, CA (United States))

1992-09-01T23:59:59.000Z

251

Advanced lighting guidelines, 1993: Revision 1  

SciTech Connect

The 1993 Advanced Lighting Guidelines document consists of twelve guidelines that provide an overview of specific lighting technologies and design application techniques utilizing energy-efficient lighting practice. Lighting Design Practice assesses energy-efficient lighting strategies, discusses lighting issues, and explains how to obtain quality lighting design and consulting services. Luminaires and Lighting Systems surveys luminaire equipment designed to take advantage of advanced technology lamp products and includes performance tables that allow for accurate estimation of luminaire light output and power input. The additional ten guidelines -- Computer-Aided Lighting Design, Energy-Efficient Fluorescent Ballasts, Full-Size Fluorescent Lamps, Compact Fluorescent Lamps, Tungsten- Halogen Lamps, Metal Halide and HPS Lamps, Daylighting and Lumen Maintenance, Occupant Sensors, Time Scheduling Systems, and Retrofit Control Technologies -- each provide a product technology overview, discuss current products on the lighting equipment market, and provide application techniques. This document is intended for use by electric utility personnel involved in lighting programs, lighting designers, electrical engineers, architects, lighting manufacturers' representatives, and other lighting professionals.

Eley, C.; Tolen, T.M. (Eley Associates, San Francisco, CA (United States)); Benya, J.R. (Luminae Souter Lighting Design, San Francisco, CA (United States)); Rubinstein, F.; Verderber, R. (Lawrence Berkeley Lab., CA (United States))

1993-05-01T23:59:59.000Z

252

Advanced lighting guidelines: 1993. Final report  

Science Conference Proceedings (OSTI)

The 1993 Advanced Lighting Guidelines document consists of twelve guidelines that provide an overview of specific lighting technologies and design application techniques utilizing energy-efficient lighting practice. Lighting Design Practice assesses energy-efficient lighting strategies, discusses lighting issues, and explains how to obtain quality lighting design and consulting services. Luminaires and Lighting Systems surveys luminaire equipment designed to take advantage of advanced technology lamp products and includes performance tables that allow for accurate estimation of luminaire light output and power input. The additional ten guidelines -- Computer-Aided Lighting Design, Energy-Efficient Fluorescent Ballasts, Full-Size Fluorescent Lamps, Compact Fluorescent Lamps, Tungsten-Halogen Lamps, Metal Halide and HPS Lamps, Daylighting and Lumen Maintenance, Occupant Sensors, Time Scheduling Systems, and Retrofit Control Technologies -- each provide a product technology overview, discuss current products on the lighting equipment market, and provide application techniques. This document is intended for use by electric utility personnel involved in lighting programs, lighting designers, electrical engineers, architects, lighting manufacturers` representatives, and other lighting professionals.

Eley, C.; Tolen, T.M. [Eley Associates, San Francisco, CA (United States); Benya, J.R. [Luminae Souter Lighting Design, San Francisco, CA (United States); Rubinstein, F.; Verderber, R. [Lawrence Berkeley Lab., CA (United States)

1993-12-31T23:59:59.000Z

253

Operating Guidelines Narrative.DOC  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Competitive Sourcing Program Operating Guidelines Issued under authority of: Competitive Sourcing Executive Steering Group July 1, 2004 DOE Competitive Sourcing Program OPERATING GUIDELINES (CS-OG-01) i COMPETITIVE SOURCING PROGRAM OPERATING GUIDELINES Table of Contents 1. REFERENCES ................................................................................................................................... 1 2. PURPOSE ........................................................................................................................................... 1 3. APPLICABILITY AND SCOPE ......................................................................................................

254

Operating Guidelines Narrative.DOC  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Competitive Sourcing Program Operating Guidelines Issued under authority of: Competitive Sourcing Executive Steering Group July 1, 2004 DOE Competitive Sourcing Program OPERATING GUIDELINES (CS-OG-01) i COMPETITIVE SOURCING PROGRAM OPERATING GUIDELINES Table of Contents 1. REFERENCES ................................................................................................................................... 1 2. PURPOSE ........................................................................................................................................... 1 3. APPLICABILITY AND SCOPE ......................................................................................................

255

Guidelines manual for surface monitoring of geothermal areas  

DOE Green Energy (OSTI)

The following are covered: preliminary investigation, design of monitoring system, and monitoring operations. Included in appendices are: characteristics of geothermal subsidence, guidelines for specifications for monitoring subsidence, instruments for monitoring, formats for data presentation, and statistical analyses. (MHR)

Van Til, C.J.

1979-05-01T23:59:59.000Z

256

CRAD, Assessment Criteria and Guidelines for Determining the Adequacy of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Assessment Criteria and Guidelines for Determining the Assessment Criteria and Guidelines for Determining the Adequacy of Software Used in the Safety Analysis and Design of Defense Nuclear Facilities CRAD, Assessment Criteria and Guidelines for Determining the Adequacy of Software Used in the Safety Analysis and Design of Defense Nuclear Facilities Performance Objective: These guidelines and criteria provide a consistent overall framework for assessment of the processes that are currently in place to ensure that the software being used in the safety analysis and design of the SSCs in defense nuclear facilities is adequate. These reviews will be conducted only on software that is currently in use, not on software that was previously used as part of a safety analysis and design process. Criteria: Custom software developed by DOE, its contractors, or subcontractors

257

Inside RHIC | Submission Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

Submission Guidelines Submission Guidelines "Inside RHIC" is an online publication covering news and views of the RHIC and AGS program at Brookhaven National Laboratory at the level of engineers and students. The RHIC AGS Users Group is sponsoring this effort, and we have tried to cover the breadth of the efforts at RHIC, from physics results to machine and detector development. The articles are relatively short and not so technical; a few hundred words are enough. It is a web publication, so length is not critical, but it is better to be concise. If you write an article for RHIC News, here's what is needed: The text of the article (a plain ASCII text file is adequate, even preferable, although we can deal with almost any format) The first few sentences (maybe 100 words) should summarize the point

258

gas cylinder storage guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

Compressed Gas Cylinder Storage Guidelines Compressed Gas Cylinder Storage Guidelines All cylinders must be stored vertical, top up across the upper half the cylinder but below the shoulder. Small cylinder stands or other methods may be appropriate to ensure that the cylinders are secured from movement. Boxes, cartons, and other items used to support small cylinders must not allow water to accumulate and possible cause corrosion. Avoid corrosive chemicals including salt and fumes - keep away from direct sunlight and keep objects away that could fall on them. Use Gas pressure regulators that have been inspected in the last 5 years. Cylinders that contain fuel gases whether full or empty must be stored away from oxidizer cylinders at a minimum of 20 feet. In the event they are stored together, they must be separated by a wall 5 feet high with

259

Glove Selection Guideline  

NLE Websites -- All DOE Office Websites (Extended Search)

Glove Selection Guideline Glove Selection Guideline Skin contact is a potential source of exposure to toxic materials; it is important that the proper steps be taken to prevent such contact. Most accidents involving hands and arms can be classified under four main hazard categories: chemicals, abrasions, cutting, and heat. There are gloves available that can protect workers from any of these individual hazards or any combination thereof. Gloves should be replaced periodically, depending on frequency of use and permeability to the substance(s) handled. Gloves overtly contaminated should be rinsed and then carefully removed after use. Gloves should also be worn whenever it is necessary to handle rough or sharp-edged objects, and very hot or very cold materials. The type of glove materials to be used in these situations include leather, welderÂ’s gloves,

260

Service Water Piping Guideline  

Science Conference Proceedings (OSTI)

In the years 1988 and 1989, EPRI organized the Service Water Working Group (SWWG) to identify and help resolve the many issues surrounding service water (SW) systems in nuclear power plants. One issue identified by the SWWG was corrosion in service water piping systems. Interest in this issue resulted in the development of several technical reports: Guidelines for the Repair/Replacement Welding of Nuclear Service Water Systems, TR-100386; Guide for the Examination of Service Water System Piping, TR-10206...

2005-09-30T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Wireless Sensor Application Guideline  

Science Conference Proceedings (OSTI)

This guideline discusses the different wireless technologies in use today. Before wireless technologies were available, all the sensory connections and user interfaces in nuclear power plants had to be hard-wired. This was a limiting factor in developing a world-class condition-based maintenance (CBM) program. The wire runs were very expensive, and some equipment was in a remote or inaccessible location. With wireless technologies, adding continuous monitoring to equipment is often easy and inexpensive. ...

2002-12-29T23:59:59.000Z

262

Natural phenomena hazards performance categorization guidelines for structures, systems, and components  

Science Conference Proceedings (OSTI)

The Department of Energy (DOE) requires in DOE 5480.23 the use of a ``graded approach`` in performing safety analysis and evaluation of DOE facilities for normal operating and accident conditions, including accidents caused by natural phenomena hazard (NPH) events. DOE 5480.28 uses this graded approach and requires, for the purpose of NPH design and evaluation, placing the structures, systems, and components (SSCs) comprising the DOE facilities into five performance categories. This standard is a revision to DOE-STD-1021-92, December 1992, and provides guidelines to be used for such categorization of SSCs, and recommends systematic procedures to implement these guidelines. It applies to all DOE facilities that are covered by DOE 5480.28. (JDB)

Not Available

1993-07-01T23:59:59.000Z

263

Natural phenomena hazards performance categorization guidelines for structures, systems, and components  

Science Conference Proceedings (OSTI)

The Department of Energy (DOE) requires in DOE 5480.23 the use of a graded approach'' in performing safety analysis and evaluation of DOE facilities for normal operating and accident conditions, including accidents caused by natural phenomena hazard (NPH) events. DOE 5480.28 uses this graded approach and requires, for the purpose of NPH design and evaluation, placing the structures, systems, and components (SSCs) comprising the DOE facilities into five performance categories. This standard is a revision to DOE-STD-1021-92, December 1992, and provides guidelines to be used for such categorization of SSCs, and recommends systematic procedures to implement these guidelines. It applies to all DOE facilities that are covered by DOE 5480.28. (JDB)

Not Available

1993-07-01T23:59:59.000Z

264

-1- Georgia Guidelines for Reclaimed Water Systems for Buildings PREFACE  

E-Print Network (OSTI)

The Georgia Guidelines for Reclaimed Water Systems for Buildings are intended to assist all parties involved in the design, construction, inspection and maintenance of reclaimed water systems and to help successfully comply with Appendix J, „Reclaimed Water Systems for Buildings ? of the 2011 Georgia Amendments to the International Plumbing Code (IPC), latest adopted version. The parties mentioned above include building owners, reclaimed water purveyors, designers, contractors, and building code officials. This consensus document is the product of the guidelines committee members below:

Frances Carpenter Chairperson; Danny Johnson; Curtis Boswell; Tom Carty; Laura Walker; Ernest U. Earn; Mike Millard; Philip T. Mccreanor, Ph.D.; Phillip George; Joe Messina; Jim Poff; Guy Pihera; Conrad Gelot; Marvin Richards; Chris Kumnick; Bob Bourne

2011-01-01T23:59:59.000Z

265

ABC Guideline (vol 2) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ABC Guideline (vol 2) ABC Guideline (vol 2) An Analyst's Handbook for Analysis of Benefits and Costs ABC Guideline (vol 2) More Documents & Publications ABC Guideline (vol 1) DOE...

266

Interconnection Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Guidelines Interconnection Guidelines Interconnection Guidelines < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Wind Energy Sources Solar Home Weatherization Water Program Info State South Carolina Program Type Interconnection Provider Public Service Commission of South Carolina The South Carolina Public Service Commission (PSC) adopted simplified interconnection guidelines for small distributed generation (DG) in December 2006. These guidelines address renewable-energy systems and other forms of DG up to 20 kilowatts (kW) in capacity for residential systems,

267

Biomass Guidelines (Prince Edward Island, Canada) | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Biomass Guidelines (Prince Edward Island, Canada) Biomass Guidelines (Prince Edward Island, Canada) Eligibility Agricultural Construction Developer Industrial Investor-Owned...

268

Guidelines for Nuclear Plant Response to an Earthquake  

Science Conference Proceedings (OSTI)

Guidelines for nuclear plant response to earthquakes enable utilities to evaluate in a timely manner the need for post-earthquake plant shutdown and to provide procedures for evaluation of earthquake effects on the plant, as well as criteria for plant restart. The procedures enable the responding team of operators and engineers to identify and assess any earthquake effects and, if shutdown is necessary, to return the plant to safe operation as rapidly as possible. The guidelines presented herein ...

2013-10-15T23:59:59.000Z

269

Guidelines for Nuclear Plant Response to an Earthquake  

Science Conference Proceedings (OSTI)

Guidelines for nuclear plant response to earthquakes enable utilities to evaluate in a timely manner the need for post-earthquake plant shutdown and to provide procedures for evaluation of earthquake effects on the plant, as well as criteria for plant restart. The procedures enable the responding team of operators and engineers to identify and assess any earthquake effects and, if shutdown is necessary, to return the plant to safe operation as rapidly as possible. The guidelines presented herein ...

2012-10-11T23:59:59.000Z

270

Deriving cleanup guidelines for radionuclides at Brookhaven National Laboratory  

Science Conference Proceedings (OSTI)

Past activities at Brookhaven National Laboratory (BNL) resulted in soil and groundwater contamination. As a result, BNL was designated a Superfund site under the Comprehensive Environmental Response Compensation and Liability Act (CERCLA). BNL`s Office of Environmental Restoration (OER) is overseeing environmental restoration activities at the Laboratory. With the exception of radium, there are no regulations or guidelines to establish cleanup guidelines for radionuclides in soils at BNL. BNL must derive radionuclide soil cleanup guidelines for a number of Operable Units (OUs) and Areas of Concern (AOCs). These guidelines are required by DOE under a proposed regulation for radiation protection of public health and the environment as well as to satisfy the requirements of CERCLA. The objective of this report is to propose a standard approach to deriving risk-based cleanup guidelines for radionuclides in soil at BNL. Implementation of the approach is briefly discussed.

Meinhold, A.F.; Morris, S.C.; Dionne, B.; Moskowitz, P.D.

1997-01-01T23:59:59.000Z

271

Design and Performance Evaluation of an Hybrid Reservation-Polling MAC Protocol for Power-Line  

E-Print Network (OSTI)

Units) in a low-voltage power grid, share the transmission capacity of the power-line network. To make of data. Since wires exist to every household connected to the low-voltage grid, PLC systems can provideDesign and Performance Evaluation of an Hybrid Reservation-Polling MAC Protocol for Power-Line

Tinnirello, Ilenia

272

Tactile distance feedback for firefighters: design and preliminary evaluation of a sensory augmentation glove  

Science Conference Proceedings (OSTI)

In this paper, we describe the design and preliminary evaluation of a vibrotactile glove for distance display in low vision search contexts. Specifically, this glove was developed for firefighting applications in which users experience compromised vision ... Keywords: distance sensing, glove, sensory augmentation, smart clothing, vibrotactile display, wearable technology

Anthony Carton; Lucy E. Dunne

2013-03-01T23:59:59.000Z

273

The Design and Evaluation of a Wireless Sensor Network for Mine Safety Monitoring  

E-Print Network (OSTI)

motes for several times in Dayan Coal Mine, Inner Mongolia province. As shown in Fig.3(a), sensor nodes mote experiment in Dayan Coal Mine (b) HHMSM prototype system deployed in a lab corridor (c) HHMSMThe Design and Evaluation of a Wireless Sensor Network for Mine Safety Monitoring Xiaoguang Niu12

Huang, Changcheng

274

Evaluating functional displays for hydropower system: model-based guidance of scenario design  

Science Conference Proceedings (OSTI)

We discuss the human role in hydropower system control, noting how it is different from other supervisory control environments and noting the typical shortcomings in current displays provided to hydropower system controllers. We describe steps towards ... Keywords: Evaluation, Functional displays, Human control model, Human supervisory control, Hydropower system control, Scenario design, Situation awareness, Trust

Xilin Li; Penelope Sanderson; Rizah Memisevic; William Wong; Sanjib Choudhury

2006-10-01T23:59:59.000Z

275

Applying mobile device soft keyboards to collaborative multitouch tabletop displays: design and evaluation  

Science Conference Proceedings (OSTI)

We present an evaluation of text entry methods for tabletop displays given small display space allocations, an increasingly important design constraint as tabletops become collaborative platforms. Small space is already a requirement of mobile text entry ... Keywords: collaboration, computer-supported collaborative work (CSCW), tabletop displays, text entry

Sungahn Ko; KyungTae Kim; Tejas Kulkarni; Niklas Elmqvist

2011-11-01T23:59:59.000Z

276

Design verification and performance evaluation of an enhanced wideband CDMA receiver using channel measurements  

Science Conference Proceedings (OSTI)

The spatio-temporal array receiver (STAR) decomposes generic wideband CDMA channel responses across various parameter dimensions (e.g., time delays, multipath components, etc.) and extracts the associated time-varying parameters (i.e., analysis) before ... Keywords: analysis/synthesis, channel measurements, design verification, dynamic channel characterization, performance evaluation, wideband CDMA

Karim Cheikhrouhou; Sofiéne Affes; Ahmed Elderini; Besma Smida; Paul Mermelstein; Belhassen Sultana; Venkatesh Sampath

2005-01-01T23:59:59.000Z

277

The design and evaluation of an end-user-deployable, whole house, contactless power consumption sensor  

Science Conference Proceedings (OSTI)

We present the design, development, and evaluation of an end-user installable, whole house power consumption sensing system capable of gathering accurate real-time power use that does not require installing a current transformer around the electrical ... Keywords: energy monitoring, sensing, smart home, sustainability, ubiquitous computing

Shwetak N. Patel; Sidhant Gupta; Matthew S. Reynolds

2010-04-01T23:59:59.000Z

278

WINDOWS-BASED ACTIVE-ROUTER DESIGN AND EVALUATION Sufyan T. Faraj1  

E-Print Network (OSTI)

WINDOWS-BASED ACTIVE-ROUTER DESIGN AND EVALUATION Sufyan T. Faraj1 , Omar A. Athab1 , Kasim M. Al AR depends on the use of Windows OS, enhancing the Active Network Encapsulation Protocol (ANEP) and the efficient use of C++ programming. Windows OS and C++ language are rarely used in such projects due

279

Guidelines for Sustainable Building Design: Recommendations from...  

NLE Websites -- All DOE Office Websites (Extended Search)

and monitoring, modeling, building envelope and historic preservation (architectural), HVAC and controls, lighting, presentation. Prior to the charrette itself, the modeling and...

280

Design and evaluation of the ReKon : an integrated detection and assessment perimeter system.  

Science Conference Proceedings (OSTI)

Kontek Industries (Kannapolis, NC) and their subsidiary, Stonewater Control Systems (Kannapolis, NC), have entered into a cooperative research and development agreement with Sandia to jointly develop and evaluate an integrated perimeter security system solution, one that couples access delay with detection and assessment. This novel perimeter solution was designed to be configurable for use at facilities ranging from high-security military sites to commercial power plants, to petro/chemical facilities of various kinds. A prototype section of the perimeter has been produced and installed at the Sandia Test and Evaluation Center in Albuquerque, NM. This prototype system integrated fiber optic break sensors, active infrared sensors, fence disturbance sensors, video motion detection, and ground sensors. This report documents the design, testing, and performance evaluation of the developed ReKon system. The ability of the system to properly detect pedestrian or vehicle attempts to bypass, breach, or otherwise defeat the system is characterized, as well as the Nuisance Alarm Rate.

Dabling, Jeffrey Glenn; Andersen, Jason Jann; McLaughlin, James O. [Stonewater Control Systems, Inc., Kannapolis, NC

2013-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Closed Cooling Water Chemistry Guideline: Revision 2  

Science Conference Proceedings (OSTI)

This Closed Cooling Water Chemistry Guideline addresses the use of chemicals and monitoring methods to mitigate corrosion, fouling, and microbiological growth in the closed cooling-water (CCW) systems of nuclear and fossil-fueled power plants. The chemical additives used for these purposes depend on plant-design characteristics, water quality, operating parameters, and the specifications of the Nuclear Steam Supply System (NSSS) suppliers. The list of chemicals is not as extensive as that ...

2013-12-09T23:59:59.000Z

282

Applying Human Factors Evaluation and Design Guidance to a Nuclear Power Plant Digital Control System  

SciTech Connect

The United States (U.S.) nuclear industry, like similar process control industries, has moved toward upgrading its control rooms. The upgraded control rooms typically feature digital control system (DCS) displays embedded in the panels. These displays gather information from the system and represent that information on a single display surface. In this manner, the DCS combines many previously separate analog indicators and controls into a single digital display, whereby the operators can toggle between multiple windows to monitor and control different aspects of the plant. The design of the DCS depends on the function of the system it monitors, but revolves around presenting the information most germane to an operator at any point in time. DCSs require a carefully designed human system interface. This report centers on redesigning existing DCS displays for an example chemical volume control system (CVCS) at a U.S. nuclear power plant. The crucial nature of the CVCS, which controls coolant levels and boration in the primary system, requires a thorough human factors evaluation of its supporting DCS. The initial digital controls being developed for the DCSs tend to directly mimic the former analog controls. There are, however, unique operator interactions with a digital vs. analog interface, and the differences have not always been carefully factored in the translation of an analog interface to a replacement DCS. To ensure safety, efficiency, and usability of the emerging DCSs, a human factors usability evaluation was conducted on a CVCS DCS currently being used and refined at an existing U.S. nuclear power plant. Subject matter experts from process control engineering, software development, and human factors evaluated the DCS displays to document potential usability issues and propose design recommendations. The evaluation yielded 167 potential usability issues with the DCS. These issues should not be considered operator performance problems but rather opportunities identified by experts to improve upon the design of the DCS. A set of nine design recommendations was developed to address these potential issues. The design principles addressed the following areas: (1) color, (2) pop-up window structure, (3) navigation, (4) alarms, (5) process control diagram, (6) gestalt grouping, (7) typography, (8) terminology, and (9) data entry. Visuals illustrating the improved DCS displays accompany the design recommendations. These nine design principles serve as the starting point to a planned general DCS style guide that can be used across the U.S. nuclear industry to aid in the future design of effective DCS interfaces.

Thomas Ulrich; Ronald Boring; William Phoenix; Emily Dehority; Tim Whiting; Jonathan Morrell; Rhett Backstrom

2012-08-01T23:59:59.000Z

283

Guideline for On-Line Monitoring of Nuclear Power Plant Instrument Channel Performance  

Science Conference Proceedings (OSTI)

This report provides a guideline for a utility to develop an on-line monitoring (OLM) program for evaluating instrument channel performance at nuclear power plants (NPPs).

2011-11-08T23:59:59.000Z

284

g. tms business development guidelines  

Science Conference Proceedings (OSTI)

Guidelines on Business Development within TMS ... are in compliance with existing TMS articles of incorporation, bylaws, policies, practices, and procedures . 2.

285

APS Safety Guidelines for Beamlines  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidelines for Beamlines Accident Investigations LOM Shop Usage User Shop Access - Policies and Procedures User Shop Orientation User Shop Authorization Certification Form User...

286

Strategy Guideline: Proper Water Heater Selection  

Science Conference Proceedings (OSTI)

This strategy guideline provides step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads. These procedures, developed both for individual water heater applications (both single and multi-family) and multifamily central systems, provide users with projections on operating cost savings over a 10-year time horizon for retrofit applications and on a cash flow basis for new construction.

Hoeschele, M.; Springer, D.; German, A.; Staller, J.; Zhang, Y.

2012-08-01T23:59:59.000Z

287

Report of the US Nuclear Regulatory Commission Piping Review Committee. Volume 2. Evaluation of seismic designs: a review of seismic design requirements for Nuclear Power Plant Piping  

Science Conference Proceedings (OSTI)

This document reports the position and recommendations of the NRC Piping Review Committee, Task Group on Seismic Design. The Task Group considered overlapping conservation in the various steps of seismic design, the effects of using two levels of earthquake as a design criterion, and current industry practices. Issues such as damping values, spectra modification, multiple response spectra methods, nozzle and support design, design margins, inelastic piping response, and the use of snubbers are addressed. Effects of current regulatory requirements for piping design are evaluated, and recommendations for immediate licensing action, changes in existing requirements, and research programs are presented. Additional background information and suggestions given by consultants are also presented.

Not Available

1985-04-01T23:59:59.000Z

288

High integrity software for nuclear power plants: Candidate guidelines, technical basis and research needs. Main report, Volume 2  

Science Conference Proceedings (OSTI)

The work documented in this report was performed in support of the US Nuclear Regulatory Commission to examine the technical basis for candidate guidelines that could be considered in reviewing and evaluating high integrity computer e following software development and assurance activities: Requirements specification; design; coding; verification and validation, inclukding static analysis and dynamic testing; safety analysis; operation and maintenance; configuration management; quality assurance; and planning and management. Each activity (framework element) was subdivided into technical areas (framework subelements). The report describes the development of approximately 200 candidate guidelines that span the entire ran e identification, categorization and prioritization of technical basis for those candidate guidelines; and the identification, categorization and prioritization of research needs for improving the technical basis. The report has two volumes: Volume 1, Executive Summary includes an overview of the framwork and of each framework element, the complete set of candidate guidelines, the results of the assessment of the technical basis for each candidate guideline, and a discussion of research needs that support the regulatory function; this document, Volume 2, is the main report.

Seth, S.; Bail, W.; Cleaves, D.; Cohen, H.; Hybertson, D.; Schaefer, C.; Stark, G.; Ta, A.; Ulery, B. [Mitre Corp., McLean, VA (United States)

1995-06-01T23:59:59.000Z

289

Guidelines for identification of concrete in a materials property database  

SciTech Connect

Guidelines for the identification of concrete in a materials property database are presented to address the complex problem of distinguishing one concrete from another. These guidelines are based on a logical scheme for systematically organizing and subdividing data and information about concrete and its constituents; they reflect consensus recommendations for a multilevel material description and designation system. Aspects of the guidelines include a classification system used to establish a series of primary identifiers, methods for reporting constituent information and mixture proportions, fields describing the source of the concrete and its processing history, and recommendations for reporting baseline or reference properties.

Oland, C.B. [Oak Ridge National Lab., TN (United States). Engineering Technology Div.; Frohnsdorff, G. [National Inst. of Standards and Technology, Gaithersburg, MD (United States)

1995-12-31T23:59:59.000Z

290

A manual for implementing residual radioactive material guidelines  

Science Conference Proceedings (OSTI)

This manual presents information for implementing US Department of Energy (DOE) guidelines for residual radioactive material at sites identified by the Formerly Utilized Sites Remedial Action Program (FUSRAP) and the Surplus Facilities Management Program (SFMP). It describes the analysis and models used to derive site-specific guidelines for allowable residual concentrations of radionuclides in soil and the design and use of the RESRAD computer code for calculating guideline values. It also describes procedures for implementing DOE policy for reducing residual radioactivity to levels that are as low as reasonably achievable. 36 refs., 16 figs, 22 tabs.

Gilbert, T.L.; Yu, C.; Yuan, Y.C.; Zielen, A.J.; Jusko, M.J.; Wallo, A. III

1989-06-01T23:59:59.000Z

291

HRP-CP: AN EVALUATION OF THE DESIGN FEATURES OF BLANKET PROCESSING LOOP P- 1  

DOE Green Energy (OSTI)

The design features and the performance of UO/sub 2/SO/sub 4/ blanket processing Loop P-1 are evaluated from an engineering viewpoint. This unique experiment development loop was operated with pump heating to study the behavior of plutonium in 1.4 M UO/sub 2/SO/sub 4/at 250 deg C and was designed for mixed O/ sub 2/-H/sub 2/ gas pressurization The canned loop and the feed and sampling systems in glove boxes completely contained the plutonium throughout the experimental program. (auth)

Snider, J.W.; Clinton, S.D.

1958-10-22T23:59:59.000Z

292

In situ technology evaluation and functional and operational guidelines for treatability studies at the radioactive waste management complex at the Idaho National Engineering Laboratory  

SciTech Connect

The purpose of this document is to provide EG G Idaho's Waste Technology Development Department with a basis for selection of in situ technologies for demonstration at the Radioactive Waste Management Complex (RWMC) of the Idaho National Engineering Laboratory (INEL) and to provide information for Feasibility Studies to be performed according to the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA). The demonstrations will aid in meeting Environmental Restoration/Waste Management (ER/WM) schedules for remediation of waste at Waste Area Group (WAG) 7. This report is organized in six sections. Section 1, summarizes background information on the sites to be remediated at WAG-7, specifically, the acid pit, soil vaults, and low-level pits and trenches. Section 2 discusses the identification and screening of in situ buried waste remediation technologies for these sites. Section 3 outlines the design requirements. Section 4 discusses the schedule (in accordance with Buried Waste Integrated Demonstration (BWID) scoping). Section 5 includes recommendations for the acid pit, soil vaults, and low-level pits and trenches. A listing of references used to compile the report is given in Section 6. Detailed technology information is included in the Appendix section of this report.

Hyde, R.A.; Donehey, A.J.; Piper, R.B.; Roy, M.W.; Rubert, A.L.; Walker, S.

1991-07-01T23:59:59.000Z

293

Evaluation and Design of Utility Co-Owned Cogeneration Systems for Industrial Parks  

E-Print Network (OSTI)

The Electric Power Research Institute, EPRI, is currently evaluating the potential of utility co-owned cogeneration facilities in industrial parks. This paper describes part of the work performed by one of EPRI's contractors, Impell Corporation, chosen by EPRI to support the industrial parks study. Cogeneration benefits for park owners, tenants and the local utilities are presented. A method developed for selecting industrial park sites for cogeneration facilities and design and financing options are also discussed.

Hu, D. S.; Tamaro, R. F.; Schiller, S. R.

1984-01-01T23:59:59.000Z

294

Evaluating Indoor Air Quality (IAQ) as Modifying Factor in Designing Public School Buildings in Jordan  

E-Print Network (OSTI)

The most fundamental goal in the design of educational facilities is to provide an environment that encourages learning achievement for students and teachers. Poor indoor air quality (IAQ) can negatively affect student health, comfort and performance that will eventually produce unacceptable learning environment. Poor IAQ can decrease a person's ability to perform specific mental tasks requiring concentration, calculation and memory. Therefore, schools should be designed, built and maintained in away to minimize and control the source of pollution. Around 29% of Jordanians occupy school buildings each day. A specific prototype building design was applied in the different locations of the country. This prototype could be appropriate for one location but it is not for the entire country that has diversity in climatic and environmental conditions The purpose of this research paper was to evaluate the indoor air quality in public school buildings in urban and rural area, through investigations of the causes and its effects on student health, comfort, and performance. Achieving healthy indoor air quality is a multifaceted a problem which can be arrived at by a comprehensive and interdisciplinary approach to the design, construction and operation of the school building. Results indicate that the prototype system used was not appropriate as healthy school design, and it did not take into consideration the indoor environmental factors as crucial issue in designing school buildings.

Ali, H. H.; Al-Momani, H.

2004-01-01T23:59:59.000Z

295

System and Equipment Troubleshooting Guideline  

Science Conference Proceedings (OSTI)

This guideline outlines a generic process for use by power plant personnel engaged in the troubleshooting of plant systems and equipment. The structured approach presented in the guideline will be helpful for any plant personnel engaged in these activities, whether working individually or as part of a troubleshooting team.

2002-01-22T23:59:59.000Z

296

Open Cooling Water Chemistry Guideline  

Science Conference Proceedings (OSTI)

State-of-the-art chemistry programs help to ensure the continued operation of open cooling water systems while mitigating corrosion and fouling mechanisms. This document, Open Cooling Water Chemistry Guideline, prepared by a committee of industry experts, reflects field and laboratory data on corrosion and fouling issues of open cooling systems.BackgroundService Water System Chemical Addition Guideline (Electric Power Research Institute ...

2012-09-17T23:59:59.000Z

297

Lube Oil Predictive Maintenance, Handling, and Quality Assurance Guideline  

Science Conference Proceedings (OSTI)

This guideline has been prepared by EPRI to assist member utilities in the improvement of maintenance processes. It presents the key elements that should be included in conducting comprehensive lubrication program evaluations and in setting up a well-organized lubrication program. EPRI believes that utilities can make organizational and procedural improvements that will yield optimal lubrication programs. This guideline also serves as an excellent reference document because it describes key lubrication t...

2002-12-18T23:59:59.000Z

298

Guidelines for residential commissioning  

E-Print Network (OSTI)

Potential Benefits of Commissioning California Homes”.Delp. 2000. “Residential Commissioning: A Review of Relatedfor Evaluating Residential Commissioning Metrics” Lawrence

Wray, Craig P.; Walker, Iain S.; Sherman, Max H.

2003-01-01T23:59:59.000Z

299

Evaluation of a New Remote Handling Design for High Throughput Annular Centrifugal Contactors  

Science Conference Proceedings (OSTI)

Advanced designs of nuclear fuel recycling plants are expected to include more ambitious goals for aqueous based separations including; higher separations efficiency, high-level waste minimization, and a greater focus on continuous processes to minimize cost and footprint. Therefore, Annular Centrifugal Contactors (ACCs) are destined to play a more important role for such future processing schemes. Previous efforts defined and characterized the performance of commercial 5 cm and 12.5 cm single-stage ACCs in a “cold” environment. The next logical step, the design and evaluation of remote capable pilot scale ACCs in a “hot” or radioactive environment was reported earlier. This report includes the development of remote designs for ACCs that can process the large throughput rates needed in future nuclear fuel recycling plants. Novel designs were developed for the remote interconnection of contactor units, clean-in-place and drain connections, and a new solids removal collection chamber. A three stage, 12.5 cm diameter rotor module has been constructed and evaluated for operational function and remote handling in highly radioactive environments. This design is scalable to commercial CINC ACC models from V-05 to V-20 with total throughput rates ranging from 20 to 650 liters per minute. The V-05R three stage prototype was manufactured by the commercial vendor for ACCs in the U.S., CINC mfg. It employs three standard V-05 clean-in-place (CIP) units modified for remote service and replacement via new methods of connection for solution inlets, outlets, drain and CIP. Hydraulic testing and functional checks were successfully conducted and then the prototype was evaluated for remote handling and maintenance suitability. Removal and replacement of the center position V-05R ACC unit in the three stage prototype was demonstrated using an overhead rail mounted PaR manipulator. This evaluation confirmed the efficacy of this innovative design for interconnecting and cleaning individual stages while retaining the benefits of commercially reliable ACC equipment for remote applications in the nuclear industry. Minor modifications and suggestions for improved manual remote servicing by the remote handling specialists were provided but successful removal and replacement was demonstrated in the first prototype.

David H. Meikrantz; Troy G. Garn; Jack D. Law; Lawrence L. Macaluso

2009-09-01T23:59:59.000Z

300

Guidelines for developing effective Estimation of Distribution Algorithms in solving single machine scheduling problems  

Science Conference Proceedings (OSTI)

The goal of this research is to deduce important guidelines for designing effective Estimation of Distribution Algorithms (EDAs). These guidelines will enhance the designed algorithms in balancing the intensification and diversification effects of EDAs. ... Keywords: Diversification, Estimation of Distribution Algorithms, Intensification, Just-in-time, Single machine scheduling problems

Shih-Hsin Chen; Min-Chih Chen; Pei-Chann Chang; Qingfu Zhang; Yuh-Min Chen

2010-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Occupant Evaluation of Leadership in Energy and Environmental Design (LEED) Certified Health Centers  

E-Print Network (OSTI)

Globally, concern for natural resource depletion is growing. The healthcare industry is looking to improve healthcare environments by improving design and using better resources. The U.S. Green Building Council has created the Leadership in Energy and Environmental Design (LEED) standard that gives suggestions on how to best use energy, water, land, materials and provide a comfortable indoor environment. Many health centers have used this standard to build new health facilities. It is important that the LEED standards benefit the environment as well as healthcare staff. This study presents four case studies of LEED health centers whose medical staff and administrators evaluate the perceivable green building features applied to their facility. All facilities were given the Occupant Evaluation of LEED Certified Health Centers Survey. The Patrick Dollard Discovery Health Center, the Richard J. Lacks Cancer Center, the Angel Harvey Infant Welfare of Chicago, and the Pearland Pediatric centers received overall satisfactory scores from the occupants. Within the case studies variations in satisfaction occurred where LEED points were not received. There is no evidence that perceivable features used in the design and construction of LEED certified health centers decrease occupant satisfaction.

Hill, Anorea M.

2009-08-01T23:59:59.000Z

302

Design and Evaluation of an Enhanced In-Vessel Core Catcher  

SciTech Connect

An enhanced in-vessel core catcher is being designed and evaluated as part of a joint United States (U.S.) - Korean International Nuclear Engineering Research Initiative (INERI) investigating methods to insure In-Vessel Retention (IVR) of core materials that may relocate under severe accident conditions in advanced reactors. To reduce cost and simplify manufacture and installation, this new core catcher design consists of several interlocking sections that are machined to fit together when inserted into the lower head. If needed, the core catcher can be manufactured with holes to accommodate lower head penetrations. Each section of the core catcher consists of two material layers with an option to add a third layer (if deemed necessary): a base material, which has the capability to support and contain the mass of core materials that may relocate during a severe accident; an oxide coating material on top of the base material, which resists interactions with high-temperature core materials; and an optional coating on the bottom side of the base material to prevent any potential oxidation of the base material during the lifetime of the reactor. This paper summarizes the status of core catcher design and evaluation efforts, including analyses, materials interaction tests, and prototypic testing efforts.

Joy L. Rempe

2004-06-01T23:59:59.000Z

303

Energy Department Launches Better Buildings Workforce Guidelines...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Launches Better Buildings Workforce Guidelines Project Energy Department Launches Better Buildings Workforce Guidelines Project September 26, 2013 - 2:38pm Addthis The Energy...

304

Health Information Technology (IT), Human Factor Guidelines  

Science Conference Proceedings (OSTI)

... on a research program aimed at developing human factors guidelines for ... technical guidelines will help support safe, effective, error-free EHR use ...

2013-08-05T23:59:59.000Z

305

Energy Indicators for Sustainable Development: Guidelines and...  

Open Energy Info (EERE)

Development: Guidelines and Methodologies Jump to: navigation, search Tool Summary Name: Energy Indicators for Sustainable Development: Guidelines and Methodologies AgencyCompany...

306

Microsoft Word - PMCDP Course Curriculum Registration Guidelines...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

course roster. PMCDP will not make any roster changes after that time. PMCDP Course Curriculum Registration Guidelines The Certification and Equivalency Guideline (CEG)...

307

Industrial Energy Audit Guidebook: Guidelines for Conducting...  

Open Energy Info (EERE)

Industrial Energy Audit Guidebook: Guidelines for Conducting an Energy Audit in Industrial Facilities Jump to: navigation, search Name Industrial Energy Audit Guidebook: Guidelines...

308

Weatherization and Intergovernmental Program: About the Guidelines...  

NLE Websites -- All DOE Office Websites (Extended Search)

About the Guidelines for Home Energy Professionals Project to someone by E-mail Share Weatherization and Intergovernmental Program: About the Guidelines for Home Energy...

309

Evaluation of Beam Loss and Energy Depositions for a Possible Phase II Design for LHC Collimation  

Science Conference Proceedings (OSTI)

The LHC beams are designed to have high stability and to be stored for many hours. The nominal beam intensity lifetime is expected to be of the order of 20h. The Phase II collimation system has to be able to handle particle losses in stable physics conditions at 7 TeV in order to avoid beam aborts and to allow correction of parameters and restoration to nominal conditions. Monte Carlo simulations are needed in order to evaluate the behavior of metallic high-Z collimators during operation scenarios using a realistic distribution of losses, which is a mix of the three limiting halo cases. Moreover, the consequences in the IR7 insertion of the worst (case) abnormal beam loss are evaluated. The case refers to a spontaneous trigger of the horizontal extraction kicker at top energy, when Phase II collimators are used. These studies are an important input for engineering design of the collimation Phase II system and for the evaluation of their effect on adjacent components. The goal is to build collimators that can survive the expected conditions during LHC stable physics runs, in order to avoid quenches of the SC magnets and to protect other LHC equipments.

Lari, L.; /EPFL-ISIC, Lausanne /CERN; Assmann, R.; /CERN; Bracco, C.; /EPFL-ISIC, Lausanne /CERN; Brugger, M.; /CERN; Cerutti, F.; /CERN; Doyle, E.; /SLAC; Ferrari, A.; /CERN; Keller, L.; Lundgren, S.; Markiewicz, Thomas W.; /SLAC; Mauri, M.; Redaelli, S.; Sarchiapone, L.; /CERN; Smith, J.; /SLAC; Vlachoudis, V.; Weiler, T.; /CERN

2011-11-07T23:59:59.000Z

310

Evaluation of Beam Losses And Energy Deposition for a Possible Phase II Design for LHC Collimation  

Science Conference Proceedings (OSTI)

The Large Hadron Collider (LHC) beams are designed to have high stability and to be stored for many hours. The nominal beam intensity lifetime is expected to be of the order of 20h. The Phase II collimation system has to be able to handle particle losses in stable physics conditions at 7 TeV in order to avoid beam aborts and to allow correction of parameters and restoration to nominal conditions. Monte Carlo simulations are needed in order to evaluate the behavior of metallic high-Z collimators during operation scenarios using a realistic distribution of losses, which is a mix of the three limiting halo cases. Moreover, the consequences in the IR7 insertion of the worst (case) abnormal beam loss are evaluated. The case refers to a spontaneous trigger of the horizontal extraction kicker at top energy, when Phase II collimators are used. These studies are an important input for engineering design of the collimation Phase II system and for the evaluation of their effect on adjacent components. The goal is to build collimators that can survive the expected conditions during LHC stable physics runs, in order to avoid quenches of the SC magnets and to protect other LHC equipments.

Lari, L.; Assmann, R.W.; Bracco, C.; Brugger, M.; Cerutti, F.; Ferrari, A.; Mauri, M.; Redaelli, S.; Sarchiapone, L.; Vlachoudis, Vasilis; Weiler, Th.; /CERN; Doyle, J.E.; Keller, L.; Lundgren, S.A.; Markiewicz, Thomas W.; Smith, J.C.; /SLAC; Lari, L.; /LPHE, Lausanne

2011-11-01T23:59:59.000Z

311

Interconnection Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Guidelines Interconnection Guidelines Interconnection Guidelines < Back Eligibility Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Wind Program Info State Missouri Program Type Interconnection Provider Missouri Department of Natural Resources Missouri enacted legislation (S.B. 54) in June 2007 requiring all of the state's electric utilities -- including municipal utilities and electric cooperatives -- to offer net metering to customers with systems up to 100 kilowatts (kW) in capacity that generate electricity using wind energy, solar-thermal energy, hydroelectric energy, photovoltaics (PV), fuel cells

312

Interconnection Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Guidelines Interconnection Guidelines Interconnection Guidelines < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Energy Sources Solar Wind Program Info State Delaware Program Type Interconnection Provider Delaware Public Service Commission '''''Note: Delaware law ([http://delcode.delaware.gov/title26/c010/index.shtml#1014 26 Del. C. § 1014]) requires the Delaware Public Service Commission (PSC), Delaware Electric Cooperative (DEC), and municipal utilities to develop interconnection rules using as a guide the Interstate Renewable Energy Council's (IREC) model interconnection rules and the U.S. Department of

313

Interconnection Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Guidelines Interconnection Guidelines Interconnection Guidelines < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State Arizona Program Type Interconnection Provider Arizona Corporation Commission '''''Note: In June 2007, the Arizona Corporation Commission (ACC) initiated a rulemaking process to establish statewide interconnection standards for distributed generation (DG). This proceeding is still in progress. Until the new official rules go into effect, the commission has recommended that the utilities use the [http://images.edocket.azcc.gov/docketpdf/0000074361.pdf Interconnection

314

Interconnection Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Interconnection Guidelines Interconnection Guidelines Interconnection Guidelines < Back Eligibility Agricultural Commercial Industrial Residential Savings Category Bioenergy Buying & Making Electricity Solar Home Weatherization Water Wind Program Info State Nebraska Program Type Interconnection Provider Nebraska Energy Office Nebraska enacted legislation in May 2009 [http://nebraskalegislature.gov/FloorDocs/101/PDF/Final/LB436.pdf (LB 436)], establishing general rules for interconnecting and net metering systems that generate electricity. Nebraska's policy applies to systems that use solar, wind, methane, biomass, hydropower or geothermal resources to produce electricity and have a rated capacity of 25 kilowatts (kW) or less. To be eligible, a facility must meet all applicable safety, performance,

315

Guidelines for carbon dioxide capture, transport and storage  

Science Conference Proceedings (OSTI)

The goal of this effort was to develop a set of preliminary guidelines and recommendations for the deployment of carbon capture and storage (CCS) technologies in the United States. The CCS Guidelines are written for those who may be involved in decisions on a proposed project: the developers, regulators, financiers, insurers, project operators, and policymakers. Contents are: Part 1: introduction; Part 2: capture; Part 3: transport; Part 4; storage; Part. 5 supplementary information. Within these parts, eight recommended guidelines are given for: CO{sub 2} capture; ancillary environmental impacts from CO{sub 2}; pipeline design and operation; pipeline safety and integrity; siting CO{sub 2} pipelines; pipeline access and tariff regulation; guidelines for (MMV); risk assessment; financial responsibility; property rights and ownership; site selection and characterisation; injection operations; site closure; and post-closure. 18 figs., 9 tabs., 4 apps.

Hanson, S.

2008-07-01T23:59:59.000Z

316

NIST Finalizes Initial Set of Smart Grid Cyber Security Guidelines |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NIST Finalizes Initial Set of Smart Grid Cyber Security Guidelines NIST Finalizes Initial Set of Smart Grid Cyber Security Guidelines NIST Finalizes Initial Set of Smart Grid Cyber Security Guidelines September 2, 2010 - 3:15pm Addthis WASHINGTON, D.C. - The National Institute of Standards and Technology (NIST) issued today its first Guidelines for Smart Grid Cyber Security, which includes high-level security requirements, a framework for assessing risks, an evaluation of privacy issues at personal residences, and additional information for businesses and organizations to use as they craft strategies to protect the modernizing power grid from attacks, malicious code, cascading errors, and other threats. The product of two formal public reviews and the focus of numerous workshops and teleconferences over the past 17 months, the three-volume set

317

Super Energy Efficiency Design (S.E.E.D.) Home Evaluation  

SciTech Connect

This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the 'Super Energy Efficient Design' (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressive energy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Source energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short term testing, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.

German, A.; Dakin, B.; Backman, C.; Weitzel, E.; Springer, D.

2012-12-01T23:59:59.000Z

318

The design evaluation of inductive power-transformer for personal rapid transit by measuring impedance  

SciTech Connect

The contact-less inductive power transformer (IPT) uses the principle of electromagnetic induction. The concept of the IPT for vehicles such as the personal rapid transit (PRT) system is proposed and some suggestions for power collector design of IPT to improve power transfer performance are presented in this paper. The aim of this paper is to recommend the concept of IPT for vehicles such as the PRT system and also to present some propositions for the power collector design of the IPT, which is to improve the power transfer performance. Generally, there are diverse methods to evaluate transfer performance of the traditional transformers. Although the principle of IPT is similar to that of the general transformer, it is impossible to apply the methods directly because of large air gap. The system must be compensated by resonant circuit due to the large air gap. Consequently, it is difficult to apply numerical formulas to the magnetic design of IPT systems. This paper investigates the magnetic design of a PRT system using three-dimensional magnetic modeling and measurements of the pick-up coupling coefficient and its impedances. In addition, how the use of Litz wire and leakage inductance is related will be observed through experiment and simulation.

Han, Kyung-Hee [Department of Electrical Engineering, Dongguk University, Seoul 100-715 (Korea, Republic of); Department of Electricity and Signaling, Korea Railroad Research Institute, Uiwang, Kyonggi 437-050 (Korea, Republic of); Lee, Byung-Song [Department of Electricity and Signaling, Korea Railroad Research Institute, Uiwang, Kyonggi 437-050 (Korea, Republic of); Baek, Soo-Hyun [Department of Electrical Engineering, Dongguk University, Seoul 100-715 (Korea, Republic of)

2008-04-01T23:59:59.000Z

319

Review and evaluation of design analysis methods for calculating flexibility of nozzles and branch connections  

SciTech Connect

Modern piping system design generally includes an analytical determination of displacements, rotations, moments, and reaction forces at various postions along the piping system by means of a flexibility analysis. The analytical model is normally based on a strength-of-materials description of the piping system as an interconnected set of straight and curved beams, along with ''flexibility factors'' that are used to compensate for inaccuracies in the model behavior. This report gives an in-depth evaluation of the various analytical descriptions of the flexibility factors associated with piping system branch connection and nozzles. Recommendations are given for developing needed improvements. 59 refs., 29 figs., 26 tabs.

Moore, S.E.; Rodabaugh, E.C.; Mokhtarian, K.; Gwaltney, R.C.

1987-12-01T23:59:59.000Z

320

Guidelines for strategic planning  

SciTech Connect

Strategic planning needs to be done as one of the integral steps in fulfilling our overall Departmental mission. The role of strategic planning is to assure that the longer term destinations, goals, and objectives which the programs and activities of the Department are striving towards are the best we can envision today so that our courses can then be set to move in those directions. Strategic planning will assist the Secretary, Deputy Secretary, and Under Secretary in setting the long-term directions and policies for the Department and in making final decisions on near-term priorities and resource allocations. It will assist program developers and implementors by providing the necessary guidance for multi-year program plans and budgets. It is one of the essential steps in the secretary's Strategic Planning Initiative. The operational planning most of us are so familiar with deals with how to get things done and with the resources needed (people, money, facilities, time) to carry out tasks. Operating plans like budgets, capital line item projects, R D budgets, project proposals, etc., are vital to the mission of the Department. They deal, however, with how to carry out programs to achieve some objective or budget assumption. Strategic planning deals with the prior question of what it is that should be attempted. It deals with what objectives the many programs and activities of the Department of Department should be striving toward. The purpose of this document is to provide guidance to those organizations and personnel starting the process for the first time as well as those who have prepared strategic plans in the past and now wish to review and update them. This guideline should not be constructed as a rigid, restrictive or confining rulebook. Each organization is encouraged to develop such enhancements as they think may be useful in their planning. The steps outlined in this document represent a very simplified approach to strategic planning. 9 refs.

1991-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Guidelines for Carcinogen Risk Assessment  

NLE Websites -- All DOE Office Websites (Extended Search)

P-03/001F P-03/001F March 2005 Guidelines for Carcinogen Risk Assessment Risk Assessment Forum U.S. Environmental Protection Agency Washington, DC DISCLAIMER This document has been reviewed in accordance with U.S. Environmental Protection Agency policy and approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use. CONTENTS 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.1. PURPOSE AND SCOPE OF THE GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2. ORGANIZATION AND APPLICATION OF THE GUIDELINES . . . . . . . . . . . 1-3 1.2.1. Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1.2.2. Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1.3. KEY FEATURES OF THE CANCER GUIDELINES .

322

Materials Guidelines for Gasification Plants  

Science Conference Proceedings (OSTI)

This report distills and condenses EPRI's knowledge of materials performance in numerous pilot and commercial-scale gasifiers into guidelines for the application and expected performance of materials in key parts of gasification-combined-cycle power plants.

1998-06-16T23:59:59.000Z

323

Biodiesel Handling and Use Guidelines  

DOE Green Energy (OSTI)

This document is a field guide for end-users, distributors, and those involved in related activities. These guidelines cover fuel use and handling issues that could be anticipated or encountered in the field.

Tyson, S.

2001-09-05T23:59:59.000Z

324

Guidelines for Electromagnetic Interference Testing  

Science Conference Proceedings (OSTI)

One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I&C) systems in recent years is electromagnetic compatibility (EMC). Guidance from the Nuclear Regulatory Commission (NRC), EPRI, and various standards organizations has been evolving for many years and generally converging. However, the NRC's most recent guidance, Regulatory Guide 1.180 Revision 1, and EPRI's most recent EMI Guideline (Guidelines for Electromagnetic Interference Testing in...

2008-02-21T23:59:59.000Z

325

Guidelines for solar energy installations  

SciTech Connect

Guidelines for solar energy installations are presented. The guideline is published in code form so that it can be used directly as the text of an ordinance to regulate the installation of solar systems. An index contains cross references to sections of existing model codes that are applicable to solar installations. Wind energy systems, passive solar space conditioning systems, photovoltaic systems, and systems involving mechanical compression of refrigerants are not included.

1984-01-01T23:59:59.000Z

326

Methodologies and new user interfaces to optimize hydraulic fracturing design and evaluate fracturing performance for gas wells  

E-Print Network (OSTI)

This thesis presents and develops efficient and effective methodologies for optimal hydraulic fracture design and fracture performance evaluation. These methods incorporate algorithms that simultaneously optimize all of the treatment parameters while accounting for required constraints. Damage effects, such as closure stress, gel damage and non-Darcy flow, are also considered in the optimal design and evaluation algorithms. Two user-friendly program modules, which are active server page (ASP) based, were developed to implement the utility of the methodologies. Case analysis was executed to demonstrate the workflow of the two modules. Finally, to validate the results from the two modules, results were compared to those from a 3D simulation program. The main contributions of this work are: An optimal fracture design methodology called unified fracture design (UFD) is presented and damage effects are considered in the optimal design calculation. As a by-product of UFD, a fracture evaluation methodology is proposed to conduct well stimulation performance evaluation. The approach is based on calculating and comparing the actual dimensionless productivity index of fractured wells with the benchmark which has been developed for optimized production. To implement the fracture design and evaluation methods, two web ASP based user interfaces were developed; one is called Frac Design (Screening), and the other is Frac Evaluation. Both modules are built to hold the following features. o Friendly web ASP based user interface o Minimum user input o Proppant type and mesh size selection o Damage effects consideration options o Convenient on-line help.

Wang, Wenxin

2005-12-01T23:59:59.000Z

327

Using modeling to design and evaluate transient open ocean iron enrichment for carbon sequestration  

NLE Websites -- All DOE Office Websites (Extended Search)

Using modeling to design and evaluate Using modeling to design and evaluate transient open ocean iron enrichment for carbon sequestration Richard T. Barber (rbarber@duke.edu; 252-504-7578) Duke University Marine Laboratory 135 Duke Marine Lab Road Beaufort, NC 28516-9721 Fei Chai (fchai@maine.edu; 207-581-4317) University of Maine School of Marine Sciences 5741 Libby Hall Orono, ME 04469-5741 Introduction During the 1990s the rate of increase of CO 2 in the atmosphere was about 3.5 Pg C y -1 . Total emissions were 7.4 Pg C y -1 , so about 3.9 Pg C y -1 (52% of total emissions) were sequestered naturally. Of this, about 2.2 Pg C y -1 was absorbed by the oceans and 1.7 Pg C y -1 by the land (US DOE, 1999). The Kyoto Protocol of 1997 calls for a 34% reduction of emissions by 2050 and a reduction of 70% from the projected emissions at 2100. The major approach to

328

Measure Guideline: Hybrid Foundation Insulation Retrofits  

Science Conference Proceedings (OSTI)

This measure guideline provides recommendations for designs and variations for retrofit hybrid assemblies in improving interior foundation insulation and water management of basements. Variations include closed cell spray foam (ccSPF) with membrane waterproofing or air gap membrane drainage layers, rigid board foam insulation at flat walls (cast concrete or CMU block), a 'partial drainage' detail making use of the bulk water drainage that occurs through the field of a rubble stone wall, and non-drained spray foam assemblies (including slab insulation).

Ueno, K.; Lstiburek, J.

2012-05-01T23:59:59.000Z

329

Fuel Reliability Guidelines: Pellet-Cladding Interaction  

Science Conference Proceedings (OSTI)

These Guidelines will assist utilities in making informed decisions to prevent PCI of fuel duty failures.

2008-12-22T23:59:59.000Z

330

METHODOLOGY FOR WORKER NEUTRON EXPOSURE EVALUATION IN THE PDCF FACILITY DESIGN  

Science Conference Proceedings (OSTI)

A project headed by Washington Group International is meant to design the Pit Disassembly and Conversion Facility (PDCF) to convert the plutonium pits from excessed nuclear weapons into plutonium oxide for ultimate disposition. Battelle staff are performing the shielding calculations that will determine appropriate shielding so that the facility workers will not exceed target exposure levels. The target exposure levels for workers in the facility are 5 mSv y?1 for the whole body and 100 mSv y?1 for the extremity, which presents a significant challenge to the designers of a facility that will process tons of radioactive material. The design effort depended on shielding calculations to determine appropriate thickness and composition for glove box walls, and concrete wall thicknesses for storage vaults. Pacific Northwest National Laboratory (PNNL) staff used ORIGEN-S and SOURCES to generate gamma and neutron source terms, and Monte Carlo (computer code for) neutron photon (transport) (MCNP-4C) to calculate the radiation transport in the facility. The shielding calculations were performed by a team of four scientists, so it was necessary to develop a consistent methodology. There was also a requirement for the study to be cost-effective, so efficient methods of evaluation were required. The calculations were subject to rigorous scrutiny by internal and external reviewers, so acceptability was a major feature of the methodology. Some of the issues addressed in the development of the methodology included selecting appropriate dose factors, developing a method for handling extremity doses, adopting an efficient method for evaluating effective dose equivalent in a non-uniform radiation field, modeling the reinforcing steel in concrete, and modularizing the geometry descriptions for efficiency. The relative importance of the neutron dose equivalent compared with the gamma dose equivalent varied substantially depending on the specific shielding conditions and lessons were learned from this effect. This paper addresses these issues and the resulting methodology.

Scherpelz, Robert I.; Traub, Richard J.; Pryor, Kathryn H.

2004-08-01T23:59:59.000Z

331

Design and evaluation of Cities Service/Rockwell hydrogasification commercial plant  

Science Conference Proceedings (OSTI)

This report covers a preliminary conceptual design and economic evaluation of a commercial scale plant capable of converting high-sulfur bituminous caking coal to a high-Btu pipeline quality SNG. The plant, which has a rated capacity of 250 Billion Btu per day SNG, is based on Cities Service/Rockwell hydrogasification technology. Two cases of plant design were examined to produce cost estimates accurate to +-25% in 1979 dollars. The base case, designed for moderate production of liquids (5.8% conversion of carbon to liquid product), has a cost of SNG of $4.43/MMBtu using the utility financing method (UFM) and $6.42/MMBtu using the discounted cash flow method (DCFM) of financing. The alternate case, zero liquids production, has gas costs of $5.00 (UFM) and $6.96 (DCFM). Further tests by Rockwell have indicated that 11.4% carbon conversion to liquid products (99% benzene) is possible. If the plant is scaled up to produce the same amoung of SNG with this increased yield of liquid, and if the value of the benzene produced is estimated to be $0.90 per gallon, the costs of gas for this case are $4.38/MMBtu (UFM) and $6,48/MMBtu (DCFM). If the value of benzene is taken as $2.00 per gallon, these costs become $3.14/MMBtu (UFM) and $5.23/MMBtu (DCFM). The economic assumptions involved in these calculations are detailed.

Agrawal, P.D.; Butt, N.M.; Sarma, K.R.

1980-08-01T23:59:59.000Z

332

Guidelines for ground motion definition for the eastern United States  

SciTech Connect

Guidelines for the determination of earthquake ground motion definition for the eastern United States are established here. Both far-field and near-field guidelines are given. The guidelines were based on an extensive review of the current procedures for specifying ground motion in the United States. Both empirical and theoretical procedures were used in establishing the guidelines because of the low seismicity in the eastern United States. Only a few large- to great-sized earthquakes (M/sub s/ > 7.5) have occurred in this region, no evidence of tectonic surface ruptures related to historic or Holocene earthquakes has been found, and no currently active plate boundaries of any kind are known in this region. Very little instrumented data have been gathered in the East. Theoretical procedures are proposed so that in regions of almost no data, a reasonable level of seismic ground motion activity can be assumed. The guidelines are to be used to develop the safe shutdown earthquake (SSE). A new procedure for establishing the operating basis earthquake (OBE) is proposed, in particular for the eastern United States. The OBE would be developed using a probabilistic assessment of the geological conditions and the recurrence of seismic events at a site. These guidelines should be useful in development of seismic design requirements for future reactors. 17 refs., figs., tabs.

Gwaltney, R.C.; Aramayo, G.A.; Williams, R.T.

1985-06-01T23:59:59.000Z

333

Evaluation of NEPA-based environmental commitments at four geopressure design wells  

DOE Green Energy (OSTI)

The implementation of environmental mitigation and monitoring commitments made for four geopressure design well projects was evaluated. The evaluation was based on site visits conducted in August 1982 and April 1983 and on a review of monitoring and project activity reports provided by DOE contractors. The projects evaluated include: Pleasant Bayou No. 1 in Brazoria County, Texas; Dow Parcperdue in Vermilion Parish, Louisiana; and Gladys McCall and Sweet Lake No. 1 well sites in Cameron Parish, Louisiana. The contractors responsible for drilling and testing activities at the well sites have adequately implemented most of the mitigation measures described in each project's site-specific Environmental Assessment (EA). Exceptions include the lack of impermeable liners for drilling mud pits at the Dow Parcperdue, Gladys McCall, and Pleasant Bayou sites and the lack of a ring levee at the Pleasant Bayou site. Air and water quality and noise monitoring activities were not performed as strictly as outlined in the EAs. A review of the monitoring data collected to date indicates that no significant environmental degradation has occurred. This report recommends additional or future monitoring needs, especially with regard to soil contamination, subsidence, and microseismicity, and provides guidance for decommissioning.

Reed, A.W.; Hunsaker, D.B. Jr.; Roop, R.D.; Webb, J.W.

1983-09-01T23:59:59.000Z

334

UTS Design Guidelines P-PO.01.09 UTS DESIGN GUIDELINES  

E-Print Network (OSTI)

-of-Custody ..................................................................................................................11 6.1.2 Sample Labels and Custody Seals-of-custody forms, EPA-certified clean containers, coolers, preservatives, and custody seals. The following provides the sampling effort. 6.1.2 Sample Labels and Custody Seals A sample label will be affixed to each sample

University of Technology, Sydney

335

Fire risks in the field of architecture and urban planning design process of the civil constructions, management, evaluation and control  

Science Conference Proceedings (OSTI)

Based on the text study of the Firefighting Law, a series of conclusions are risen, that are, in the same time, tasks of fire risks management, evaluation and control within architecture and urban planning design process of constructions. Fire risks ... Keywords: architecture and urban planning design process, educational model, fire risk

Gheorghe Breazu; Cristian Dumitrescu

2010-07-01T23:59:59.000Z

336

Natural Phenomena Hazards Design and Evaluation Criteria for Department of Energy Facilities  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0-2002 0-2002 January 2002 Superseding DOE-STD-1020-94 April 1994 DOE STANDARD NATURAL PHENOMENA HAZARDS DESIGN AND EVALUATION CRITERIA FOR DEPARTMENT OF ENERGY FACILITIES U.S. Department of Energy AREA NPHZ Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. TS This document has been reproduced from the best available copy. Available to DOE and DOE contractors from ES&H Technical Information Services, U.S. Department of Energy, (800) 473-4375, fax: (301) 903-9823. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 605-6000. DOE-STD-1020-2002 iii Foreword This revision provides information to help meet the requirements of 10 CFR Part 830, "Nuclear

337

Recommendations to the NRC on human engineering guidelines for nuclear power plant maintainability  

SciTech Connect

This document contains human engineering guidelines which can enhance the maintainability of nuclear power plants. The guidelines have been derived from general human engineering design principles, criteria, and data. The guidelines may be applied to existing plants as well as to plants under construction. They apply to nuclear power plant systems, equipment and facilities, as well as to maintenance tools and equipment. The guidelines are grouped into seven categories: accessibility and workspace, physical environment, loads and forces, maintenance facilities, maintenance tools and equipment, operating equipment design, and information needs. Each chapter of the document details specific maintainability problems encountered at nuclear power plants, the safety impact of these problems, and the specific maintainability design guidelines whose application can serve to avoid these problems in new or existing plants.

Badalamente, R.V.; Fecht, B.A.; Blahnik, D.E.; Eklund, J.D.; Hartley, C.S.

1986-03-01T23:59:59.000Z

338

ARM - Baseline Change Request Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

DocumentsBaseline Change Request Guidelines DocumentsBaseline Change Request Guidelines Page Contents Introduction Submit a BCR BCR Process Flowchart Baseline Change Request Guidelines Introduction Baseline Change Requests (BCR) are used by the ARM Infrastructure as a process to provide configuration control and for formally requesting and documenting changes within the ARM Infrastructure. Configuration Control: BCRs are required for changes to instruments, data systems, data processes, datastreams, measurement methods, and facilities. They help ensure that all aspects of the ARM Infrastructure are consulted prior to implementing changes. Seemingly minor changes can have significant repercussions throughout the Facility and therefore, NO change to an operational instrument, computer, facility, or other system can or will be

339

13 point video tape quality guidelines  

SciTech Connect

Until high definition television (ATV) arrives, in the U.S. we must still contend with the National Television Systems Committee (NTSC) video standard (or PAL or SECAM-depending on your country). NTSC, a 40-year old standard designed for transmission of color video camera images over a small bandwidth, is not well suited for the sharp, full-color images that todays computers are capable of producing. PAL and SECAM also suffers from many of NTSC`s problems, but to varying degrees. Video professionals, when working with computer graphic (CG) images, use two monitors: a computer monitor for producing CGs and an NTSC monitor to view how a CG will look on video. More often than not, the NTSC image will differ significantly from the CG image, and outputting it to NTSC as an artist works enables the him or her to see the images as others will see it. Below are thirteen guidelines designed to increase the quality of computer graphics recorded onto video tape. Viewing your work in NTSC and attempting to follow the below tips will enable you to create higher quality videos. No video is perfect, so don`t expect to abide by every guideline every time.

Gaunt, R.

1997-05-01T23:59:59.000Z

340

APS Preliminary Beamline Design Report Guide  

NLE Websites -- All DOE Office Websites (Extended Search)

PRELIMINARY BEAMLINE DESIGN REPORT PRELIMINARY BEAMLINE DESIGN REPORT December 5, 1994 5.1 Preliminary Beamline Design: General Guidelines The Preliminary Design of the beamline represents an approximately 30% design level of each of the beamline components. This level of design permits the CAT to develop cost estimates for the construction of the beamline, as well as a realistic timeline for completion of the construction tasks. A committee from the APS has been charged with reviewing the Preliminary Design Reports and has established the evaluation criteria described below. The Preliminary Beamline Report is expected to expand upon the Conceptual Design Report in the following areas: Beamline Layout Component Design Work Breakdown Structure Cost and Schedule Additional Operational Requirements

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

American Recovery and Reinvestment Act General Guidelines for Emblem and Logo Applications  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

// American Recovery and Reinvestment Act // General Guidelines for Emblem and Logo Applications Page 1 // American Recovery and Reinvestment Act // General Guidelines for Emblem and Logo Applications Page 1 American Recovery and Reinvestment Act General Guidelines for Emblem and Logo Applications Version 1.0 03 / 20 / 09 Projects funded by the American Recovery and Reinvestment Act (ARRA) will bear a newly-designed emblem. The emblem is a symbol of President Obama's commitment to the American People to invest their tax dollars wisely to put Americans back to work. The purpose of this document is to provide general guidelines and specifications for using the

342

Plant Process Computer Upgrade Guidelines, Volume 1: Replacement Guidelines  

Science Conference Proceedings (OSTI)

The gradual obsolescence of the original plant process computers at nuclear power plants decreases their effectiveness in supporting plant operation and maintenance. This project, based on the practical experience of utility personnel, presents guidelines on plant process computer replacement planning and implementation.

1993-01-01T23:59:59.000Z

343

Developing Guidelines for Assessing Visual Analytics Environments  

SciTech Connect

Visual analytic systems can be evaluated from a user perspective with quantitative metrics (i.e., time to complete the analysis or the accuracy of the solution found). However, qualitative measures are also useful in a user assessment. These include such measures as the utility of the interactive visualizations in the analysis process and the user's assessment of the efficiency of the analytic process. Quantitative measures can be found if data sets with embedded ground truth are used for analysis. Qualitative measures are more elusive. In this paper we report on an experiment with professional analysts who ranked five of submissions to the VAST 2009 Challenge and provided the rationale for their rankings. Their comments were used in conjunction with a meta-analysis of the 2009 VAST Challenge reviews to produce a set of guidelines for visual analytic systems. As visual analytic software is expected to eventually help in all aspects of analysis, we expect to see future systems provide more help with generating the final report. Hence, researchers also need to have an understanding of what makes a good analytic product. Therefore we asked the analysts to rank the situational assessments of four grand challenge entries and to provide comments on those assessments. We used these comments to produce guidelines for researchers to use in evaluating their analytic reports.

Scholtz, Jean

2011-09-22T23:59:59.000Z

344

Health impact assessment: A comparison of 45 local, national, and international guidelines  

SciTech Connect

This article provides a comparison of health impact assessment (HIA) guidelines from around the world and for multiple geographic scales. We identify commonalities and differences within HIA guides to discuss the plausibility of consensus guidelines and to inform guideline development. The practice of HIA has grown over the last two decades with a concurrent growth of HIA guides. This study expands on earlier review work and includes guides published since 2007 (Mindell, Boltong and Forde, 2008). From April 2010 to October 2011, 45 HIA guides were identified through an internet search and review of previous research. Common characteristics, key features, and the HIA process were analyzed. The 45 documents recommended similar but not identical processes for conducting HIAs. These analyses suggest that guidelines for HIAs are similar in many areas of the world and that new HIA practitioners can use these findings to inform their approach. Further discussion is needed to determine if the approaches established in these guidelines are followed and if one set of common guidelines could be written for use in numerous countries and regions. - Highlights: Black-Right-Pointing-Pointer We analyze 45 health impact assessment (HIA) guidelines worldwide. Black-Right-Pointing-Pointer We examine similarities and unique attributes of each guideline. Black-Right-Pointing-Pointer We discuss the advantages and disadvantages of developing consensus guidelines. Black-Right-Pointing-Pointer Identifying additional guidelines aides in future HIA work and evaluation.

Hebert, Katherine A., E-mail: jsx3@cdc.gov; Wendel, Arthur M., E-mail: dvq6@cdc.gov; Kennedy, Sarah K., E-mail: heaton.sarah@gmail.com; Dannenberg, Andrew L., E-mail: adannenberg2@gmail.com

2012-04-15T23:59:59.000Z

345

Design  

NLE Websites -- All DOE Office Websites (Extended Search)

Design Design of a Multithreaded Barnes-Hut Algorithm for Multicore Clusters Technical Report Junchao Zhang and Babak Behzad Department of Computer Science, University of Illinois at Urbana-Champaign {jczhang, bbehza2}@illinois.edu Marc Snir Department of Computer Science, University of Illinois at Urbana-Champaign and MCS Division, Argonne National Laboratory snir@anl.gov Abstract We describe in this paper an implementation of the Barnes-Hut al- gorithm on multicore clusters. Based on a partitioned global ad- dress space (PGAS) library, the design integrates intranode mul- tithreading and internode one-sided communication, exemplifying a PGAS + X programming style. Within a node, the computation is decomposed into tasks (subtasks), and multitasking is used to hide network latency. We study the tradeoffs between locality in private caches and locality in shared caches

346

Project Closeout: Guidance for Final Evaluation of Building America Communities  

Science Conference Proceedings (OSTI)

This report presents guidelines for Project Closeout. It is used to determine whether the Building America program is successfully facilitating improved design and practices to achieve energy savings goals in production homes. Its objective is to use energy simulations, targeted utility bill analysis, and feedback from project stakeholders to evaluate the performance of occupied BA communities.

Norton, P.; Burch, J.; Hendron, B.

2008-03-01T23:59:59.000Z

347

Groundwater and Soil Remediation Guidelines for Nuclear Power Plants  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute (EPRI) Groundwater and Soil Remediation Guidelines provides the nuclear power industry with technical guidance for evaluating the need for and timing of remediation of soil and/or groundwater contamination from onsite leaks, spills, or inadvertent releases to a) prevent migration of licensed material off-site and b) minimize decommissioning impacts.

2010-12-21T23:59:59.000Z

348

Substation Equipment Life Extension Guidelines  

Science Conference Proceedings (OSTI)

Utilities are under increasing pressure to maintain service reliability while operating aging transmission substations with leaner maintenance budgets and fewer experienced personnel. A structured life extension program can help utilities make equipment maintenance, replacement, and refurbishment decisions that ensure safe, reliable, cost-effective operation of transmission substation equipment. The Electric Power Research Institute (EPRI) report Life Extension Guidelines for Substation Equipment-Fi...

2011-12-21T23:59:59.000Z

349

6Bone Backbone Routing Guidelines  

Science Conference Proceedings (OSTI)

The 6Bone is an Ipv6 testbed to assist in the evolution and deployment of IPv6. Because of this, it is important that the core backbone of the IPv6 network maintain stability, and that all operators have a common set of rules and guidelines by which ...

R. Rockell; R. Fink

2000-02-01T23:59:59.000Z

350

Final safety evaluation report related to the certification of the advanced boiling water reactor design. Volume 2: Appendices  

Science Conference Proceedings (OSTI)

This safety evaluation report (SER) documents the technical review of the US Advanced Boiling Water Reactor (ABWR) standard design by the US Nuclear Regulatory Commission (NRC) staff. The application for the ABWR design was initially submitted by the General Electric Company, now GE Nuclear Energy (GE), in accordance with the procedures of Appendix O of Part 50 of Title 10 of the code of Federal Regulations (10 CFR Part 50). Later GE requested that its application be considered as an application for design approval and subsequent design certification pursuant to 10 CFR {section} 52.45. The ABWR is a single-cycle, forced-circulation, boiling water reactor (BWR) with a rated power of 3,926 megawatts thermal (MWt) and a design power of 4,005 MWt. To the extent feasible and appropriate, the staff relied on earlier reviews for those ABWR design features that are substantially the same as those previously considered. Unique features of the ABWR design include internal recirculation pumps, fine-motion control rod drives, microprocessor-based digital logic and control systems, and digital safety systems. On the basis of its evaluation and independent analyses, the NRC staff concludes that, subject to satisfactory resolution of the confirmatory items identified in Section 1.8 of this SER, GE`s application for design certification meets the requirements of Subpart B of 10 CFR Part 52 that are applicable and technically relevant to the US ABWR standard design.

Not Available

1994-07-01T23:59:59.000Z

351

Final safety evaluation report related to the certification of the advanced boiling water reactor design. Volume 1: Main report  

SciTech Connect

This safety evaluation report (SER) documents the technical review of the US Advanced Boiling Water Reactor (ABWR) standard design by the US Nuclear Regulatory Commission (NRC) staff. The application for the ABWR design was initially submitted by the General Electric Company, now GE Nuclear Energy (GE), in accordance with the procedures of Appendix O of Part 50 of Title 10 of the Code of Federal Regulations (10 CFR Part 50). Later GE requested that its application be considered as an application for design approval and subsequent design certification pursuant to 10 CFR {section} 52.45. The ABWR is a single-cycle, forced-circulation, boiling water reactor (BWR) with a rated power of 3,926 megawatts thermal (MWt) and a design power of 4,005 MWt. To the extent feasible and appropriate, the staff relied on earlier reviews for those ABWR design features that are substantially the same as those previously considered. Unique features of the ABWR design include internal recirculation pumps, fine-motion control rod drives, microprocessor-based digital logic and control systems, and digital safety systems. On the basis of its evaluation and independent analyses, the NRC staff concludes that, subject to satisfactory resolution of the confirmatory items identified in Section 1.8 of this SER, GE`s application for design certification meets the requirements of Subpart B of 10 CFR Part 52 that are applicable and technically relevant to the US ABWR standard design.

Not Available

1994-07-01T23:59:59.000Z

352

Final safety evaluation report related to the certification of the Advanced Boiling Water Reactor design. Supplement 1  

SciTech Connect

This report supplements the final safety evaluation report (FSER) for the US Advanced Boiling Water Reactor (ABWR) standard design. The FSER was issued by the US Nuclear Regulatory Commission (NRC) staff as NUREG-1503 in July 1994 to document the NRC staff`s review of the US ABWR design. The US ABWR design was submitted by GE Nuclear Energy (GE) in accordance with the procedures of Subpart B to Part 52 of Title 10 of the Code of Federal Regulations. This supplement documents the NRC staff`s review of the changes to the US ABWR design documentation since the issuance of the FSER. GE made these changes primarily as a result of first-of-a-kind-engineering (FOAKE) and as a result of the design certification rulemaking for the ABWR design. On the basis of its evaluations, the NRC staff concludes that the confirmatory issues in NUREG-1503 are resolved, that the changes to the ABWR design documentation are acceptable, and that GE`s application for design certification meets the requirements of Subpart B to 10 CFR Part 52 that are applicable and technically relevant to the US ABWR design.

NONE

1997-05-01T23:59:59.000Z

353

Interim consensus guidelines on fossil plant cycle chemistry. Final report  

Science Conference Proceedings (OSTI)

US utilities have been faced with a multitude of water and steam control limits disseminated by various groups and manufacturers. These have provided disparate goals for plant personnel and management in determining the operating limits for their plants. EPRI authorized the preparation of guidelines on fossil plant cycle chemistry as part of a research program, RP2712, with the goal to reduce forced outages and efficiency losses related to water chemistry, corrosion, and deposition. This report is a unified, specific, and comprehensive document that provides the guidance needed for effective and economical control of corrosion and deposition. Implementation of these Guidelines will help reduce forced outages caused by corrosion-induced failures and thereby increase unit availability. The Guidelines provide a set of target values and action levels for critical sample points throughout the water and steam cycle for drum boilers with phosphate treatment; for drum boilers with all-volatile treatment; and for once-through boilers. They are applicable to baseload and to cycling and peaking operation. Corrective actions to be taken when the Guidelines are exceeded are also discussed. More general guidelines are given on management responsibilities, layup, representative sampling, analytical methods, continuous instrumentation, data collection and management, and other considerations. The Guidelines and the results of the other phases of the EPRI Research Project 2712 should bring significant benefits to US utilities at a moderate cost. Modification of portions of the Guidelines to reflect actual, plant-specific design characteristics and local operating experience is recommended when appropriately justified. 118 refs., 88 figs., 24 tabs.

Aschoff, A.F.; Lee, Y.H.; Sopocy, D.M.; Jonas, O.

1986-06-01T23:59:59.000Z

354

Forrestal Garage Parking Guidelines, Revised August 12, 2010...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Forrestal Garage Parking Guidelines, Revised August 12, 2010 Forrestal Garage Parking Guidelines, Revised August 12, 2010 Forrestal Garage Parking Guidelines Forrestal Garage...

355

Guidelines for Secure Use of Social Media by Federal Departments...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Guidelines for Secure Use of Social Media by Federal Departments and Agencies Guidelines for Secure Use of Social Media by Federal Departments and Agencies Guidelines for Secure...

356

Guidelines and Toolkits for Urban Transport Development in Medium Sized  

Open Energy Info (EERE)

Guidelines and Toolkits for Urban Transport Development in Medium Sized Guidelines and Toolkits for Urban Transport Development in Medium Sized Cities in India Jump to: navigation, search Tool Summary Name: Guidelines and Toolkits for Urban Transport Development in Medium Sized Cities in India Agency/Company /Organization: Asian Development Bank Focus Area: Governance - Planning - Decision-Making Structure Topics: Best Practices Complexity/Ease of Use: Not Available Website: sti-india-uttoolkit.adb.org/ Transport Toolkit Region(s): Asia Related Tools Promoting Clean Cars: Case Study of Stockholm and Sweden MOtor Vehicle Emission Simulator (MOVES) The World Bank - Transport ... further results Find Another Tool FIND TRANSPORTATION TOOLS This resource is designed to help decision makers and practitioners in states and municipal governments who are concerned with urban transport

357

Guidelines for Participating in the DOE Challenge Home | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Buildings » Challenge Home » Guidelines for Residential Buildings » Challenge Home » Guidelines for Participating in the DOE Challenge Home Guidelines for Participating in the DOE Challenge Home The DOE Challenge Home is a new and compelling way to recognize builders for their leadership in increasing energy efficiency, improving indoor air quality, and making homes zero net-energy ready. The program builds upon the comprehensive building science requirements of ENERGY STAR® for Homes Version 3, along with proven Building America innovations and best practices. Other special attribute programs are incorporated to help builders reach unparalleled levels of performance with homes designed to last hundreds of years. DOE Challenge Homes are verified by a qualified third-party and are at least 40%-50% more energy efficient than a typical new home. This generally

358

Job Counting Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mission » Recovery Act » Job Counting Guidelines Mission » Recovery Act » Job Counting Guidelines Job Counting Guidelines The following updated definitions and guidelines are intended to provide EM Recovery Act sites with information to collect and report timely and accurate full-time equivalent and cumulative head-count data for both monthly and quarterly jobs data calls. These revised guidelines supersede the previous monthly jobs data reporting definitions and guidelines dated February 9, 2010. These revised guidelines remain consistent with OMB guidance issued December 18, 2009 and cover subcontractors and vendors as well as prime contractors. Job Counting Guidelines More Documents & Publications EA-1548: Finding of No Significant Impact Microsoft Word - Horizon Wind Energy Comments.docx Proceedings of the Computational Needs for the Next Generation Electric

359

DOE Webcast - Better Buildings Workforce Guidelines Project ...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Webcast - Better Buildings Workforce Guidelines Project DOE Webcast - Better Buildings Workforce Guidelines Project November 7, 2013 3:00PM EST Online https:www1.gotomeeting.com...

360

AOCS Analytical Guidelines Ja 12-89  

Science Conference Proceedings (OSTI)

Analysis of Lecithin Co-Products AOCS Analytical Guidelines Ja 12-89 Methods Downloads Methods Downloads AOCS DEFINITION These guidelines identify standard methods that are recommended for th

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Design and Evaluation of a Net Zero Energy Low-Income Residential Housing Development in Lafayette, Colorado  

NLE Websites -- All DOE Office Websites (Extended Search)

Design and Evaluation of a Design and Evaluation of a Net Zero Energy Low-Income Residential Housing Development in Lafayette, Colorado Jesse Dean and Otto VanGeet National Renewable Energy Laboratory Scott Simkus Boulder County Housing Authority Mark Eastment Mountain Energy Partnership Technical Report NREL/TP-7A40-51450 March 2012 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 Design and Evaluation of a Net Zero Energy Low-Income Residential Housing Development in Lafayette,

362

Evaluation of NEPA-based environmental commitments at four geopressured geothermal design wells  

DOE Green Energy (OSTI)

This study verifies the implementation and effectiveness of environmental mitigation and monitoring commitments made by the US Department of Energy in National Environmental Policy Act documents (Environmental Assessments (EAs)) prepared for four geopressure design well projects, one in Texas and three in Louisiana. The evaluation was based on visits to the project sites conducted by Oak Ridge National Laboratory staff in August 1982 and April 1983, and on a review of monitoring and project activity reports provided by DOE subcontractors. Subcontractors responsible for drilling and testing activities at the well sites adequately implemented most of the mitigation measures described in each project's EA. Exceptions included the lack of impermeable liners for drilling mud pits at three sites and the lack of a ring levee at one site. Water quality, noise, and air monitoring were not performed as strictly as outlined in the EAs. A review of the data collected to date indicates that no significant environmental degradation has occurred. Additional or future monitoring needs, especially with regard to subsidence, microseismicity, and groundwater and soil sampling were recommended.

Reed, A.W.; Hunsaker, D.B. Jr.; Roop, R.D.; Webb, J.W.

1983-01-01T23:59:59.000Z

363

Reference wind speed distributions and height profiles for wind turbine design and performance evaluation applications. [USA  

DOE Green Energy (OSTI)

The purpose of this report is to provide a set of reference or standard values of wind profiles, wind speed distributions and their effects on wind turbine performance for engineering design applications. Based on measured Weibull distribution parameters, representative average, low, and high variance data are given for height profiles of mean, 25 percentile, and 75 percentile wind speeds; and for wind speed probability density (velocity frequency) functions and cumulative probability (velocity duration) functions at selected heights. Results of a sensitivity analysis of the dependence of wind turbine performance parameters on cut-in speed, and rated speed for various mean wind and wind variance regimes are also presented. Wind turbine performance is expressed in terms of capacity factor (ratio of mean power output to rated power) and recovery factor (ratio of mean energy output to energy theoretically available in the wind). The representative high, mean, and low variance cases were determined from calculated Weibull distributions at 140 sites across the Continental U.S., and all of the representative functions are evaluated at mean wind speeds of 4, 5, 6, 7, and 8 m/s at standard 10 m level.

Justus, C.G.; Hargraves, W.R.; Mikhail, A.

1976-08-01T23:59:59.000Z

364

Design and performance evaluations of generic programming techniques in a R&D prototype of Geant4 physics  

E-Print Network (OSTI)

A R&D project has been recently launched to investigate Geant4 architectural design in view of addressing new experimental issues in HEP and other related physics disciplines. In the context of this project the use of generic programming techniques besides the conventional object oriented is investigated. Software design features and preliminary results from a new prototype implementation of Geant4 electromagnetic physics are illustrated. Performance evaluations are presented. Issues related to quality assurance in Geant4 physics modelling are discussed.

M. G. Pia; P. Saracco; M. Sudhakar; A. Zoglauer; M. Augelli; E. Gargioni; C. H. Kim; L. Quintieri; P. P. de Queiroz Filho; D. de Souza Santos; G. Weidenspointner; M. Begalli

2010-01-15T23:59:59.000Z

365

Energy-efficient buildings program evaluations. Volume 1: Findings and recommendations  

SciTech Connect

This study was conducted for the US Department of Energy (DOE) by Pacific Northwest National Laboratory (PNNL). DOE operates the Building Standards and Guidelines Program (BSGP) to increase the effectiveness of building energy codes, standards, and guidelines. The main purpose of this report is to lay the groundwork for conducting an overall evaluation of the program and its effectiveness. Another purpose of this report is to summarize an extensive set of relevant evaluations and provide a building efficiency and program evaluation information resource for program designers, managers, and evaluators. This study presents information from 119 evaluations that have been conducted of both utility and code programs related to energy efficiency in new residential and commercial buildings. The authors used the information in these evaluations to identify major themes and lessons learned from utility and code programs. They also used the information to gain insights into appropriate evaluation methodologies and establish guidelines for designing future evaluations and an evaluation of the BSGP. The report presents general lessons about evaluating programs that have implications for future evaluations included the following. The evaluations provided the basis for developing an effective evaluation approach for residential building energy-efficiency codes and other energy-efficiency programs and other insights for conducting commercial building program evaluations. The findings for conducting effective evaluations are categorized by steps in the evaluation process.

Lee, A.D.; Mayi, D.; Edgemon, S.D.

1997-04-01T23:59:59.000Z

366

PWR core design, neutronics evaluation and fuel cycle analysis for thorium-uranium breeding recycle  

Science Conference Proceedings (OSTI)

This paper was focused on core design, neutronics evaluation and fuel cycle analysis for Thorium-Uranium Breeding Recycle in current PWRs, without any major change to the fuel lattice and the core internals, but substituting the UOX pellet with Thorium-based pellet. The fuel cycle analysis indicates that Thorium-Uranium Breeding Recycle is technically feasible in current PWRs. A 4-loop, 193-assembly PWR core utilizing 17 x 17 fuel assemblies (FAs) was taken as the model core. Two mixed cores were investigated respectively loaded with mixed reactor grade Plutonium-Thorium (PuThOX) FAs and mixed reactor grade {sup 233}U-Thorium (U{sub 3}ThOX) FAs on the basis of reference full Uranium oxide (UOX) equilibrium-cycle core. The UOX/PuThOX mixed core consists of 121 UOX FAs and 72 PuThOX FAs. The reactor grade {sup 233}U extracted from burnt PuThOX fuel was used to fabrication of U{sub 3}ThOX for starting Thorium-. Uranium breeding recycle. In UOX/U{sub 3}ThOX mixed core, the well designed U{sub 3}ThOX FAs with 1.94 w/o fissile uranium (mainly {sup 233}U) were located on the periphery of core as a blanket region. U{sub 3}ThOX FAs remained in-core for 6 cycles with the discharged burnup achieving 28 GWD/tHM. Compared with initially loading, the fissile material inventory in U{sub 3}ThOX fuel has increased by 7% via 1-year cooling after discharge. 157 UOX fuel assemblies were located in the inner of UOX/U{sub 3}ThOX mixed core refueling with 64 FAs at each cycle. The designed UOX/PuThOX and UOX/U{sub 3}ThOX mixed core satisfied related nuclear design criteria. The full core performance analyses have shown that mixed core with PuThOX loading has similar impacts as MOX on several neutronic characteristic parameters, such as reduced differential boron worth, higher critical boron concentration, more negative moderator temperature coefficient, reduced control rod worth, reduced shutdown margin, etc.; while mixed core with U{sub 3}ThOX loading on the periphery of core has no visible impacts on neutronic characteristics compared with reference full UOX core. The fuel cycle analysis has shown that {sup 233}U mono-recycling with U{sub 3}ThOX fuel could save 13% of natural uranium resource compared with UOX once through fuel cycle, slightly more than that of Plutonium single-recycling with MOX fuel. If {sup 233}U multi-recycling with U{sub 3}ThOX fuel is implemented, more natural uranium resource would be saved. (authors)

Bi, G.; Liu, C.; Si, S. [Shanghai Nuclear Engineering Research and Design Inst., No. 29, Hongcao Road, Shanghai, 200233 (China)

2012-07-01T23:59:59.000Z

367

MBM fuel feeding system design and evaluation for FBG pilot plant  

Science Conference Proceedings (OSTI)

Highlights: Black-Right-Pointing-Pointer A 1-5 g/s fuel feeding system for pilot scale FBG was designed, built and tested. Black-Right-Pointing-Pointer Multiple conveying stages improve pressure balancing, flow control and stability. Black-Right-Pointing-Pointer Secondary conveyor stage reduced output irregularity from 47% to 15%. Black-Right-Pointing-Pointer Pneumatic air sparging effective in dealing with poor flow ability of MBM powder. Black-Right-Pointing-Pointer Pneumatic injection port plugs with char at gasification temperature of 850 Degree-Sign C. - Abstract: A biomass fuel feeding system has been designed, constructed and evaluated for a fluidized bed gasifier (FBG) pilot plant at the University of Saskatchewan (Saskatoon, SK, Canada). The system was designed for meat and bone meal (MBM) to be injected into the gasifier at a mass flow-rate range of 1-5 g/s. The designed system consists of two stages of screw conveyors, including a metering stage which controlled the flow-rate of fuel, a rotary airlock and an injection conveyor stage, which delivered that fuel at a consistent rate to the FBG. The rotary airlock which was placed between these conveyors, proved unable to maintain a pressure seal, thus the entire conveying system was sealed and pressurized. A pneumatic injection nozzle was also fabricated, tested and fitted to the end of the injection conveyor for direct injection and dispersal into the fluidized bed. The 150 mm metering screw conveyor was shown to effectively control the mass output rate of the system, across a fuel output range of 1-25 g/s, while the addition of the 50 mm injection screw conveyor reduced the irregularity (error) of the system output rate from 47% to 15%. Although material plugging was found to be an issue in the inlet hopper to the injection conveyor, the addition of air sparging ports and a system to pulse air into those ports was found to successfully eliminate this issue. The addition of the pneumatic injection nozzle reduced the output irregularity further to 13%, with an air supply of 50 slpm as the minimum air supply to drive this injector. After commissioning of this final system to the FBG reactor, the injection nozzle was found to plug with char however, and was subsequently removed from the system. Final operation of the reactor continues satisfactorily with the two screw conveyors operating at matching pressure with the fluidized bed, with the output rate of the system estimated based on system characteristic equations, and confirmed by static weight measurements made before and after testing. The error rate by this method is reported to be approximately 10%, which is slightly better than the estimated error rate of 15% for the conveyor system. The reliability of this measurement prediction method relies upon the relative consistency of the physical properties of MBM with respect to its bulk density and feeding characteristics.

Campbell, William A., E-mail: bill.campbell@usask.ca [Fluidization Laboratory of Saskatchewan (FLASK) (Canada) and Department of Chemical and Biological Engineering, University of Saskatchewan (Canada); Fonstad, Terry [Department of Chemical and Biological Engineering, University of Saskatchewan (Canada); Pugsley, Todd [Suncor Energy Inc., Calgary, Alberta (Canada); Gerspacher, Regan [Fluidization Laboratory of Saskatchewan (FLASK) (Canada); Department of Chemical and Biological Engineering, University of Saskatchewan (Canada)

2012-06-15T23:59:59.000Z

368

Guidelines for Ecological Risk Assessment  

NLE Websites -- All DOE Office Websites (Extended Search)

5/002F 5/002F April 1998 Guidelines for Ecological Risk Assessment (Published on May 14, 1998, Federal Register 63(93):26846-26924) Risk Assessment Forum U.S. Environmental Protection Agency Washington, DC DISCLAIMER This document has been reviewed in accordance with U.S. Environmental Protection Agency policy and approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use. NOTICE This report contains the full text of the Guidelines for Ecological Risk Assessment. However, the format of this version differs from the Federal Register version, as follows: text boxes that are included in this document at their point of reference were instead listed at the end of the Federal Register document as text notes, due to format limitations for Federal Register documents.

369

Interconnection Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Bioenergy Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Kansas Program Type Interconnection Provider Kansas Corporation Commission Kansas adopted the Net Metering and Easy Connection Act in May 2009 (see K.S.A. 66-1263 through 66-1271), establishing interconnection guidelines and net metering for customer-owned generators. Net metering and the accompanying interconnection guidelines apply to systems that generate electricity using solar, wind, methane, biomass or hydro resources, and to fuel cells using hydrogen produced by an eligible renewable technology, with a rated capacity of 25 kilowatts (kW) or less for residential customers, 200 kW or less for non-residential customers and 1.5 megawatts

370

Condenser In-Leakage Guideline  

Science Conference Proceedings (OSTI)

The Condenser In-Leakage Guideline will assist engineers and chemists in identifying and locating air and water in-leakage leaks. It outlines the principles of operation of common condenser air-removal equipment. By keeping the air in-leakage within the capability of the air-removal equipment, condenser back pressure can be maintained. By keeping the water in-leakage as low as possible, condensate chemistry can be maintained.

2000-01-31T23:59:59.000Z

371

Guidelines for Intelligent Asset Replacement  

Science Conference Proceedings (OSTI)

EPRI8217s asset management research focuses on developing a rational basis for selecting repair or replacement options for specific classes of equipment by balancing the risks of equipment failure against the costs of continued maintenance or capital replacement. This report, the fourth report on guidelines for asset replacement, discusses methods for making decisions about wood poles. It significantly enhances a prior report on this subject by explicitly modeling pole degradation, inspection and test ef...

2006-12-18T23:59:59.000Z

372

Guidelines for Makeup Water Treatment  

Science Conference Proceedings (OSTI)

The quality of boiler and heat recovery steam generator HRSG cycle makeup water is central to ensuring the necessary purity of boiler or HRSG water, feedwater, and steam. It plays an important role in ensuring component availability and reliability in fossil and combined cycle plants. This report presents up-to-date guidelines based on proven approaches for producing makeup water from various raw water supplies. Major losses of availability in fossil fuel plants are attributable to water and steam contam...

2010-12-23T23:59:59.000Z

373

Deep Borehole Disposal Research: Demonstration Site Selection Guidelines,  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Deep Borehole Disposal Research: Demonstration Site Selection Deep Borehole Disposal Research: Demonstration Site Selection Guidelines, Borehole Seals Design, and RD&D Needs Deep Borehole Disposal Research: Demonstration Site Selection Guidelines, Borehole Seals Design, and RD&D Needs The U.S. Department of Energy has been investigating deep borehole disposal as one alternative for the disposal of spent nuclear fuel and other radioactive waste forms, along with research and development for mined repositories in salt, granite, and clay, as part of the used fuel disposition (UFD) campaign. The deep borehole disposal concept consists of drilling a borehole on the order of 5,000 m deep, emplacing waste canisters in the lower part of the borehole, and sealing the upper part of the borehole with bentonite and concrete seals. A reference design of the

374

CONCEPTUAL DESIGN AND ECONOMIC EVALUATION OF A STEAM-COOLED FAST BREEDER REACTOR  

SciTech Connect

A conceptual design and economic evaluation of 300 and 40 MW/.sub e/ steam-cooled fast breeder reactor power plants were performed. A reactor core composed of U-Pu oxide rod-type fuel elements clad with Inconel-X and surrounded by a blanket of depleted UO/sub 2/ fuel was studied in some detail. Reactor breeding ratios of from 1.27 to 1.5 and overall system doubling times of from 20 to 30 years are achievable. For the near term (1967) 300 MW/sub e/ plant, an energy cost of 7.6 mills/kwh is estimated, based on AEC ground rules for privately financed plants and utilities. This cost may go down to 5.7 mills/kwh by 1975. For the 40 MW/sub e/ plant corresponding energy costs are 19.5 and 13.7 mills/kwh, r -spectively. The R&D program required for this reactor concept is estimated at million with an additional million for improvements leading to the 1975 reactor. Investigation of the operational and safety aspects of the reactor indicated that satisfactory procedures can be used for startup, shutdown, and emergency cooling of the reactor. An increase in reactivity upon flooding can be prevented by incorprating small amounts of high resonance absorption material in the core. Preliminary calculations indicate a substantial increase in reactivity upon loss of coolant for the 300 MW/sub e/ PuO/sub 2/ fueled reactor. To obtain designs with satisfactory voiding characteristics it may be necessary to provide high neutron leakage as ib a low L/D core or smaller volume core. Acceptable voiding characteristics appear possible with a Pu fueled 40 MWe reactor cooled with H/O steam, a Pu fueled 300MW/sub w/,reactor cooled with D/O steam, and a 300 MW/sub e/ U/sup 233/-Th fueled 300 MW/sub e/ breeder reactor cooled with H/sub 2/O steam. (auth)

Sofer, G.; Hankel, R.; Goldstein, L.; Birman, G.

1961-11-15T23:59:59.000Z

375

Evaluation criteria for blog design and analysis of causal relationships using factor analysis and DEMATEL  

Science Conference Proceedings (OSTI)

The purpose of this study is to find the key factors influencing blog design, and explore the causal relationships between the criteria for each factor. Since design is a multiple criteria decision-making (MCDM) problem, this study adopts a model which ... Keywords: Blog design, DEMATEL, Factor analysis, Multiple criteria decision-making (MCDM)

Chun-Cheng Hsu

2012-01-01T23:59:59.000Z

376

Synthesis and Evaluation of CO2 Thickeners Designed with Molecular Modeling  

DOE Green Energy (OSTI)

The objective of this research was to use molecular modeling techniques, coupled with our prior experimental results, to design, synthesize and evaluate inexpensive, non-fluorous carbon dioxide thickening agents. The first type of thickener that was considered was associating polymers. Typically, these thickeners are copolymers that contain a highly CO{sub 2}-philic monomer, and a small concentration of a CO{sub 2}-phobic associating monomer. Yale University was solely responsible for the synthesis of a second type of thickener; small, hydrogen bonding compounds. These molecules have a core that contains one or more hydrogen-bonding groups, such as urea or amide groups. Non-fluorous, CO{sub 2}-philic functional groups were attached to the hydrogen bonding core of the compound to impart CO{sub 2} stability and macromolecular stability to the linear 'stack' of these compounds. The third type of compound initially considered for this investigation was CO{sub 2}-soluble surfactants. These surfactants contain conventional ionic head groups and composed of CO{sub 2}-philic oligomers (short polymers) or small compounds (sugar acetates) previously identified by our research team. Mobility reduction could occur as these surfactant solutions contacted reservoir brine and formed mobility control foams in-situ. The vast majority of the work conducted in this study was devoted to the copolymeric thickeners and the small hydrogen-bonding thickeners; these thickeners were intended to dissolve completely in CO{sub 2} and increase the fluid viscosity. A small but important amount of work was done establishing the groundwork for CO{sub 2}-soluble surfactants that reduced mobility by generating foams in-situ as the CO{sub 2}+surfactant solution mixed with in-situ brine.

Robert Enick; Erick Beckman; J. Karl Johnson

2009-08-31T23:59:59.000Z

377

2005 Adjudicative Guidelines Implementation | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

05 Adjudicative Guidelines Implementation 05 Adjudicative Guidelines Implementation 2005 Adjudicative Guidelines Implementation On December 29,2005, the President approved a revision of the Adjudicative Guidelines for Determining Eligibility for Access to Classified Information. The revised guidelines were distributed as an attachment to a memorandum from Stephen J. Hadley, Assistant to the President for National Security Affairs, addressed to William Leonard, Director of the Information Security Oversight Office. In his memorandum, Mr. Hadley instructed Mr. Leonard to circulate the revised guidelines for immediate implementation by all agencies that grant security clearances. Mr. Hadley further emphasized that all agencies must honor clearances granted under the new guidelines, consistent with Executive Order (E.O.) 12968 and the December 12,2005,

378

Evaluating alternatives for housing India's urban poor : design studies, model and application in Ahmedabad  

E-Print Network (OSTI)

The study evaluates the three alternatives identified by the (National) Planning Commission for housing the Urban Poor in India: Upgrading, site and services, and housing. The basis for evaluation is the relationship of ...

Palamadai, Rajagopalan M

1982-01-01T23:59:59.000Z

379

Evaluation of the Impact of Off-Design Operation on an Air-Cooled Binary Power Plant  

DOE Green Energy (OSTI)

Geothermal power plants are designed and constructed to provide a rated power output at specific resource and ambient conditions. Due to both diurnal and seasonal changes in the ambient air temperature, as well as a decline in resource productivity over time, plants seldom operate at these ''design'' conditions. This paper examines the impact of ''off- design'' operation of an air-cooled binary geothermal power plant. An available energy analysis is used to evaluate operation at these conditions. This evaluation identifies those portions of the power cycle that are most sensitive to changing resource and ambient conditions, as well as where improvements in cycle component or system performance would have the largest impact in increasing power output.

Mines, G.L.

2002-06-17T23:59:59.000Z

380

Evaluation of a Business Case for Safeguards by Design in Nuclear Power Reactors  

Science Conference Proceedings (OSTI)

Safeguards by Design (SbD) is a well-known paradigm for consideration and incorporation of safeguards approaches and associated design features early in the nuclear facility development process. This paradigm has been developed as part of the Next Generation Safeguards Initiative (NGSI), and has been accepted as beneficial in many discussions and papers on NGSI or specific technologies under development within NGSI. The Office of Nuclear Safeguards and Security funded the Pacific Northwest National Laboratory to examine the business case justification of SbD for nuclear power reactors. Ultimately, the implementation of SbD will rely on the designers of nuclear facilities. Therefore, it is important to assess the incentives which will lead designers to adopt SbD as a standard practice for nuclear facility design. This report details the extent to which designers will have compelling economic incentives to adopt SbD.

Wood, Thomas W.; Seward, Amy M.; Lewis, Valerie A.; Gitau, Ernest TN; Zentner, Michael D.

2012-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Sandia National Laboratory Photovoltaic Design Resources | Open Energy  

Open Energy Info (EERE)

Sandia National Laboratory Photovoltaic Design Resources Sandia National Laboratory Photovoltaic Design Resources Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Photovoltaic Design Resources at Sandia National Laboratories Agency/Company /Organization: Sandia National Laboratories Sector: Energy Focus Area: Renewable Energy, Solar Topics: Pathways analysis Website: www.sandia.gov/ References: Sandia's Photovoltaic Research and Development Program [1] Sandia National Laboratories' Photovoltaic Research and Development program works with industry and academia to accelerate development and acceptance of technologies for photovoltaic energy systems. The program has published a series of handbooks and booklets that describe design guidelines for stand-alone photovoltaic system installations, photovoltaic water pumping systems, and evaluating photvoltaic applications

382

Development and Application of Advanced Models for Steam Hydrogasification: Process Design and Economic Evaluation.  

E-Print Network (OSTI)

??This thesis is aimed at the process development, design, modeling and optimization of synthetic fuels, power and Substitute Natural Gas (SNG) production from coal and… (more)

Lu, Xiaoming

2012-01-01T23:59:59.000Z

383

Design and evaluation of heat transfer fluids for direct immersion cooling of electronic systems .  

E-Print Network (OSTI)

??Comprehensive molecular design was used to identify new heat transfer fluids for direct immersion phase change cooling of electronic systems. Four group contribution methods for… (more)

Harikumar Warrier, Pramod Kumar Warrier

2012-01-01T23:59:59.000Z

384

Evaluating How Attributes of Operable Window Design Affect Office-workers' Perception of Personal Control.  

E-Print Network (OSTI)

??Energy and environmental concerns warrant reconsideration of operable windows as a means of ventilating and cooling office environments. To design for optimal window use and… (more)

Vorderbruggen, Joan Marie

2009-01-01T23:59:59.000Z

385

Comments Sought on NIST Guidelines for Structural Fire ...  

Science Conference Proceedings (OSTI)

... by NIST that involved experts in the design and construction industry and academia ... design as well as the evaluation of concrete and steel structures ...

2011-12-02T23:59:59.000Z

386

Guidelines for Selecting Cool Roofs  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

BUILDING TECHNOLOGIES PROGRAM BUILDING TECHNOLOGIES PROGRAM Guidelines for Selecting Cool Roofs July 2010 V. 1.2 Prepared by the Fraunhofer Center for Sustainable Energy Systems for the U.S. Department of Energy Building Technologies Program and Oak Ridge National Laboratory under contract DE-AC05-00OR22725. Additional technical support provided by Lawrence Berkeley National Laboratory and the Federal Energy Management Program. Authors: Bryan Urban and Kurt Roth, Ph.D. ii Table of Contents Introduction ..................................................................................................................................... 3 Why Use Cool Roofs .............................................................................................................. 3

387

Evaluating the design, use and learnability of household products for older individuals  

Science Conference Proceedings (OSTI)

Assessing the usability of products, interfaces and artefacts from an inclusive design perspective can widen cross-market acceptability and adoption, enhancing their potential commercial success. This paper is part of ongoing research that attempts to ... Keywords: inclusive design, prior experience, product interaction learning

Christopher Wilkinson; Patrick Langdon; P. John Clarkson

2011-07-01T23:59:59.000Z

388

Software openness: evaluating parameters of parametric modeling tools to support creativity and multidisciplinary design integration  

Science Conference Proceedings (OSTI)

The ubiquitous computing era has pushed the Architecture, Engineering, and Construction (AEC) industry towards new frontiers of digitally enabled practice. Are these the frontiers originally identified by the pioneers in the field? Architectural design ... Keywords: CAD, CAE, parametric design, parametric modeling, software openness

Flora Dilys Salim; Jane Burry

2010-03-01T23:59:59.000Z

389

Evaluating and improving the effectiveness and efficiency of design process communication  

Science Conference Proceedings (OSTI)

Project information management research enables the efficient exchange of information, but does not effectively communicate process. Design process management research effectively communicates processes, but with methods too inefficient to be adopted ... Keywords: Collaboration, Communication, Design process, Information management, Knowledge management, Validation method

Reid R. Senescu, John R. Haymaker

2013-04-01T23:59:59.000Z

390

Interim guidelines for protecting fire-fighting personnel from multiple hazards at nuclear plant sites: Final report  

Science Conference Proceedings (OSTI)

This report provides interim guidelines for reducing the impact to fire fighting and other supporting emergency response personnel from the multiple hazards of radiation, heat stress, and trauma when fighting a fire in a United States commercial nuclear power plant. Interim guidelines are provided for fire brigade composition, training, equipment, procedures, strategies, heat stress and trauma. In addition, task definitions are provided to evaluate and further enhance the interim guidelines over the long term. 19 refs.

Klein, A.R.; Bloom, C.W.

1989-07-01T23:59:59.000Z

391

Memorandum, Adjudicative Guidelines Implementation - February 21, 2006 |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Adjudicative Guidelines Implementation - February 21, Adjudicative Guidelines Implementation - February 21, 2006 Memorandum, Adjudicative Guidelines Implementation - February 21, 2006 February 21,2006 The following adjudicative guidelines are established for all U.S. government civilian and military personnel, consultants, contractors, employees of contractors, licensees, certificate holders or grantees and their employees and other individuals who require access to classified information. "On December 29,2005, the President approved a revision of the Adjudicative Guidelines for Determining Eligibility for Access to Classified Information. The revised guidelines were distributed as an attachment to a memorandum f?om Stephen J. Hadley, Assistant to the President for National Security Affairs, addressed to William Leonard, Director of the Information Security

392

Guidelines for identifying suspect/counterfeit material  

SciTech Connect

These guidelines are intended to assist users of products in identifying: substandard, misrepresented, or fraudulently marked items. The guidelines provide information about such topics as: precautions, inspection and testing, dispositioning identified items, installed inspection and reporting suspect/counterfeit materials. These guidelines apply to users who are developing procurement documents, product acceptance/verification methods, company procedures, work instructions, etc. The intent of these SM guidelines in relation to the Quality Assurance Program Description (QAPD) and implementing company Management Control Procedures is not to substitute or replace existing requirements, as defined in either the QAPD or company implementing instructions (Management Control Procedures). Instead, the guidelines are intended to provide a consolidated source of information addressing the issue of Suspect/Counterfeit materials. These guidelines provide an extensive suspect component listing and suspect indications listing. Users can quickly check their suspect items against the list of manufacturers products (i.e., type, LD. number, and nameplate information) by consulting either of these listings.

NONE

1995-09-01T23:59:59.000Z

393

Compilation of EPRI Heat Recovery Steam Generator (HRSG) Guidelines  

Science Conference Proceedings (OSTI)

Combined-cycle units with heat recovery steam generators (HRSGs) represent a substantial portion of new installed generation worldwide since the 1990s. Despite being relative new, these units have experienced a significant loss of availability and reliability due to tubing failures. Many of these failures are attributed to poor design, improper operation, weaknesses in fabrication, and poor installation practices. This product is a compilation of nine (9) key individual guidelines developed to address re...

2007-12-20T23:59:59.000Z

394

Coal Fleet Integrated Gasification Combined Cycle (IGCC Permitting) Guidelines  

Science Conference Proceedings (OSTI)

This report provides guidance to owners of planned Integrated Gasification Combined Cycle (IGCC) power plants in order to assist them in permitting these advanced coal power generation facilities. The CoalFleet IGCC Permitting Guidelines summarize U.S. federal requirements for obtaining air, water, and solid waste permits for a generic IGCC facility, as described in the CoalFleet User Design Basis Specification (UDBS). The report presents characteristics of IGCC emissions that must be considered in the p...

2006-03-14T23:59:59.000Z

395

Generic Testability and Test Methods Guidelines for ASIC Devices  

Science Conference Proceedings (OSTI)

Application specific integrated circuit (ASIC) devices can cost- effectively perform the same functions as analog modules. In fact, functions performed by several analog modules can be incorporated into one ASIC device. Qualification testing, however, is needed to ensure the high reliability required of ASIC devices used in nuclear power plant safety and control systems. This report presents guidelines for designing high- reliability ASIC devices that support cost-effective qualification testing.

1996-04-30T23:59:59.000Z

396

Gas Turbine and Generator Procurement Guidelines: Best Practices and Specification  

Science Conference Proceedings (OSTI)

This report provides a specification in the style used by engineering, procurement, and construction (EPC) firms for procuring gas turbines and associated generators and accessories, as well as guidelines that describe best practices for defining the functional design requirements for such equipment. BackgroundGas turbines, fired by readily available natural gas, provide the majority of new power generation worldwide. Changes in the mix of generation ...

2012-10-29T23:59:59.000Z

397

Gas Turbine Repair Guidelines: GE 9FA  

Science Conference Proceedings (OSTI)

For more than a decade, the Electric Power Research Institute (EPRI) has been developing gas turbine hot section component repair and coating guidelines to assist utilities in the refurbishment of these critical and expensive parts. Utilities, generators, and repair vendors have used these guidelines to perform repairs on blades, turbine vanes, and combustion hardware. Guidelines now exist for a variety of conventional and advanced General Electric, Siemens/Westinghouse, Alstom, and Mitsubishi heavy ...

2012-12-12T23:59:59.000Z

398

Gas Turbine Repair Guidelines: Alstom GT26  

Science Conference Proceedings (OSTI)

For more than a decade, the Electric Power Research Institute (EPRI) has been developing gas turbine hot section component repair and coating guidelines to assist utilities and power generators in the refurbishment of these critical and expensive parts. Utilities, generators, and repair vendors have used these guidelines to perform repairs on turbine blades, vanes, and combustion hardware. The guidelines in this volume address the specific features of the Alstom GT26 gas turbine.

2011-11-03T23:59:59.000Z

399

Gas Turbine Repair Guidelines: GE 7FA  

Science Conference Proceedings (OSTI)

For more than a decade, the Electric Power Research Institute (EPRI) has been developing gas turbine hot section component repair and coating guidelines to assist utilities in the refurbishment of these critical and expensive parts. Utilities, generators, and repair vendors have used these guidelines to perform repairs on blades, turbine vanes, and combustion hardware. Guidelines now exist for a variety of conventional and advanced General Electric, Siemens/Westinghouse, Alstom, and Mitsubishi heavy fram...

2011-12-27T23:59:59.000Z

400

Combined Cycle Performance Tracking Guideline: Interim Report  

Science Conference Proceedings (OSTI)

The Electric Power Research Institute’s (EPRI’s) Combined Cycle Performance Monitoring and Recovery Guideline (EPRI report 1023971) was developed in 2012 to provide plant owners and operators with a comprehensive guideline for identifying and quantifying combined-cycle performance losses and appropriate recovery activities for a generic F-Class combined-cycle power plant (CCPP). This report, Combined-Cycle Performance Tracking Guideline, has been developed as an adjunct ...

2013-12-23T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Condensate Polishing Guidelines for Fossil Plants  

Science Conference Proceedings (OSTI)

Fossil plants employ condensate polishers to remove ionic and suspended impurities from the condensate in order to provide high purity feedwater. In the process, the polisher enhances fossil unit availability, reliability, and performance. In 1996, EPRI produced Condensate Polishing Guidelines (TR-104422), the first comprehensive guidelines for condensate polishers used in fossil units. Extensive investigations of condensate polishing technology followed. These guidelines reflect the latest thinking on t...

2006-03-15T23:59:59.000Z

402

Design and evaluation of a benchmark for main memory transaction processing systems  

E-Print Network (OSTI)

We designed a diverse collection of benchmarks for Main Memory Database Systems (MMDBs) to validate and compare entries in a programming contest. Each entrant to the contest programmed an indexing system optimized for ...

Reid, Elizabeth G

2009-01-01T23:59:59.000Z

403

The evolution and evaluation of an interactive engineering design teaching tool : MIT's EDICS  

E-Print Network (OSTI)

For this thesis, I refined and tested a computer-based engineering teaching tool called EDICS. EDICS (Engineering Design Instructional Computer Program) has proven to be a fun and intriguing means of conveying a wide variety ...

Jimenez, Craig Edward

2006-01-01T23:59:59.000Z

404

Projection of fractures in ships for the evaluation of fatigue resistant designs  

E-Print Network (OSTI)

Cracks in ships have been of great concern to the maritime industry for a very long time. The problem is controlled by improving design, minimizing operating stresses and through regular inspections and repairs. The big ...

Hadjiyiannis, Nicholas

2009-01-01T23:59:59.000Z

405

A comprehensive evaluation of the MIT Bachelor of Science in Art and Design program  

E-Print Network (OSTI)

The purpose of this thesis was to conduct a survey that would determine the source of MIT Department of Architecture undergraduate dissatisfaction with the Bachelor of Science in Art and Design (BSAD) degree program. It ...

Most, Jennifer L

2000-01-01T23:59:59.000Z

406

Critical Simulation Based Evaluation of Thermally Activated Building Systems (TABS) Design Models  

E-Print Network (OSTI)

Building index YOC Climate zone Use and loads Envelope CAin California CZ03 climate zone. The design models wereinvestigated the California climate zones CZ03, CZ04, CZ05,

Basu, Chandrayee

2012-01-01T23:59:59.000Z

407

Design and evaluation of an internet-based personalized instructional system for social psychology  

Science Conference Proceedings (OSTI)

Two iterations of an Internet-based Personalized System of Instruction (PSI) course are described. The course was designed to capitalize on the unique advantages of the PSI system while using the Internet to overcome some of its noted administrative ...

Erica Davis Blann; Donald A. Hantula

2004-01-01T23:59:59.000Z

408

Design and evaluation of a very high frequency dc/dc converter  

E-Print Network (OSTI)

This thesis presents a resonant boost topology suitable for very high frequency (VHF, 30-300 MHz) dc-dc power conversion. The proposed design is a fixed frequency, fixed duty ratio resonant converter featuring low device ...

Pilawa-Podgurski, Robert C. N

2007-01-01T23:59:59.000Z

409

Design and Evaluation of a 42-V Automotive Alternator With Integrated Switched-Mode Rectifier  

E-Print Network (OSTI)

This paper presents techniques for the design of high-power Lundell alternators with integrated switched-mode rectifiers. A multisection stator winding and interleaved rectifier arrangement is introduced that enables high ...

Tang, Sai Chun

410

Design, optimization and evaluation of a free-fall biomass fast pyrolysis reactor and its products.  

E-Print Network (OSTI)

??The focus of this work is a radiatively heated, free-fall, fast pyrolysis reactor. The reactor was designed and constructed for the production of bio-oil from… (more)

Ellens, Cody James

2009-01-01T23:59:59.000Z

411

Safety and Operational Guidelines | Open Energy Information  

Open Energy Info (EERE)

Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon Safety and Operational Guidelines Jump to: navigation, search This article is a stub. You can...

412

ENERGY STAR Guidelines for Energy Management  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidelines for Energy Guidelines for Energy Management ENERGY STAR is a U.S. Environmental Protection Agency Program helping organizations and individuals fight climate change through superior energy efficiency. Learn more at energystar.gov/buildings. 2 ENERGY STAR Guidelines for Energy Management Overview Continuous improvement of energy performance requires establishing effective energy management practices and processes to guide the energy program. Any organization, regardless of size, function, or mission can develop an effective energy program if they are willing to make the commitment. The US EPA's ENERGY STAR Guidelines for Energy Management provides a proven strategy for creating an energy management program focused on continuous improvement of energy performance. The

413

Avista Utilities - Interconnection Guidelines (Idaho) | Open...  

Open Energy Info (EERE)

page on Facebook icon Twitter icon Avista Utilities - Interconnection Guidelines (Idaho) This is the approved revision of this page, as well as being the most recent. Jump...

414

HVAC Testing, Adjusting, and Balancing Guideline  

Science Conference Proceedings (OSTI)

This report provides practical guidelines that can be used by power plant personnel to diagnose and troubleshoot heating, ventilating, and air conditioning (HVAC) system and component performance problems.

2001-10-24T23:59:59.000Z

415

Computer System Retirement Guidelines | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

adapted for use by any site or organization Computer System Retirement Guidelines More Documents & Publications DOE F 1324.9 Records Management Handbook Records Management Handbook...

416

Continuous Emission Monitoring Guidelines -- 2002 Update  

Science Conference Proceedings (OSTI)

This 2002 update to the "Continuous Emission Monitoring Guidelines" reflects information learned from current utility continuous emission monitoring (CEM) system (CEMS) installations and practices.

2002-08-30T23:59:59.000Z

417

PNNL: Technology Transfer - Our Licensing Guidelines  

NLE Websites -- All DOE Office Websites (Extended Search)

Our Licensing Guidelines PNNL approaches licensing in a flexible, collaborative manner Although every technology license is unique, at PNNL we recognize that there are basic...

418

ENERGY STAR Guidelines for Energy Management  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidelines for Energy Management ENERGY STAR is a U.S. Environmental Protection Agency Program helping organizations and individuals fight climate change through superior energy...

419

Operating Guidelines Appendix C D.DOC  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Department shall follow these guidelines, as well as relevant statutes, regulations, and DOE directives. 2. APPLICABILITY AND SCOPE The Competitive Sourcing Conflicts of Interest...

420

Weatherization and Intergovernmental Program: Guidelines for...  

NLE Websites -- All DOE Office Websites (Extended Search)

to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project Benefits on Facebook Tweet about Weatherization and...

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Weatherization and Intergovernmental Program: Guidelines for...  

NLE Websites -- All DOE Office Websites (Extended Search)

to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Employers and Contractors on Facebook Tweet...

422

h. tms mission-driven development guidelines  

Science Conference Proceedings (OSTI)

Guidelines on Mission-Driven Development within TMS ... in compliance with existing TMS articles of incorporation, bylaws, policies, practices, and procedures .

423

AOCS Analytical Guidelines S 3-64  

Science Conference Proceedings (OSTI)

Methods for the Testing of Epoxidized Oils AOCS Analytical Guidelines S 3-64 Methods Downloads Methods Downloads AOCS DEFINITION Not applicable  SCOPE

424

Steam Generator Management Program: Steam Generator Integrity Assessment Guidelines  

Science Conference Proceedings (OSTI)

This report provides guidance for evaluating the condition of steam generator (SG) tubes based on nondestructive examination (NDE) or in situ pressure testing. The integrity assessments are normally performed during a reactor refueling outage. Nuclear power plant licensees who follow the guidance in this report will have satisfied the requirements for degradation assessments, condition monitoring, and operational assessment as defined in the Nuclear Energy Institute (NEI) Steam Generator Program Guidelin...

2009-11-19T23:59:59.000Z

425

Vibration Monitoring and Analysis Program Development: Interim Guideline  

Science Conference Proceedings (OSTI)

This report has been prepared by an EPRI team and will serve as an interim guideline to assist the member utilities in the further improvement of maintenance processes by presenting, in detail, the key elements that should be included in a well-organized vibration monitoring and analysis program, as well as conducting comprehensive vibration program evaluations. This report uses the EPRI Monitoring and Diagnostics Center's "Spider Chart" approach to depict graphic representation of the vibration monitori...

2004-12-22T23:59:59.000Z

426

Guidelines on the Effects of Cycling Operation on Maintenance Activities  

Science Conference Proceedings (OSTI)

Cyclic operation can result in an increase in forced outage rates, higher operation and maintenance (O&M) costs, and further wear and tear on components due to additional overhauls and maintenance. Such operation may also increase unforeseen costs due to additional personnel training requirements and the use of more sophisticated evaluation and inspection techniques. These guidelines are intended to help plant operators and engineers assess the impact of cycling on maintenance activities and take appropr...

2001-12-10T23:59:59.000Z

427

Closed Cooling Water Chemistry Guideline, Revision 1: Revision 1 to TR-107396, Closed Cooling Water Chemistry Guideline  

Science Conference Proceedings (OSTI)

This "Closed Cooling Water Chemistry Guideline" addresses the use of chemicals to mitigate corrosion, fouling, and microbiological growth in the closed cooling water (CCW) systems of nuclear power plants. The chemical additives used for these purposes depend on plant design characteristics, water quality, operating parameters, and the specifications of nuclear steam supply system (NSSS) suppliers. The list of chemicals is not as extensive as that for service water systems but can be confusing to utility ...

2004-04-23T23:59:59.000Z

428

Transfer passenger needs at airports : human factors in terminal design  

E-Print Network (OSTI)

This thesis analyzes the needs of particular users of airport: transfer passengers. The object of this work has been to produce a set of design guidelines for terminals. these guidelines are framed upon a user-need survey ...

Brillembourg, Marie-Claire

1982-01-01T23:59:59.000Z

429

Strategy Guideline: Compact Air Distribution Systems  

SciTech Connect

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

Burdick, A.

2013-06-01T23:59:59.000Z

430

Energy Guideline Factors Provide a Better Measure of Refinery Energy Performance  

E-Print Network (OSTI)

Exxon Company, U.S.A. refineries reduced energy consumption by 25% between 1972 and 1978 compared with an 18% reduction for the U.S. Petroleum Refining Industry over the same period. The Exxon approach to conserving energy in petroleum refining operations goes beyond energy conservation housekeeping measures and investments, and uses a comprehensive method to measure energy efficiency rather than energy consumption per barrel. It uses the Exxon Research and Engineering developed energy guideline factors, which are based on energy efficient designs and criteria, to (1) Evaluate the energy efficiency performance of refineries of different complexity in a consistent manner. (2) Compensate for changes in individual process unit throughputs and in unit operating intensity/severity. (3) Identify and quantify areas of energy inefficiency. (4) Regularly monitor and steward energy efficiency performance. Effective conservation also requires the analysis of energy performance and setting goals for future improvement. The paper explains how this can be done.

Libbers, D. D.

1980-01-01T23:59:59.000Z

431

Validation and development of guidelines to select MRR strategies for rigid pavements  

E-Print Network (OSTI)

Maintenance, rehabilitation and reconstruction (MRR) work to rigid pavement roadways requires a great demand of time, effort, and money. The nature of this work not only affects state highway agencies (SHAs) but also, roadway users and local communities and businesses. This study identifies the critical issues SHAs must assess in the design phase of a MRR roadway project with the objective of selecting the preferred cost-effective pavement treatment, while minimizing traffic disruption, easing construction, and improving public acceptance. A comprehensive literature search was conducted to investigate the factors involved in the process for developing MRR strategies. Based on the literature review and assessment of current research, a decision process to develop, evaluate, and select appropriate MRR strategies was developed. This decision process was then presented to SHAs with the purpose of validating its comprehensiveness and practical nature. A guideline document that illustrates the main focus of each step of the decision process was developed. Two on-site interviews were performed with SHAs with the purpose of collecting data of two actual MRR highway projects and developing two case studies. The developed case studies illustrate the applicability of the guideline document and practical nature of the decision process.

Herrera, Edgar Efren

2001-01-01T23:59:59.000Z

432

Advanced Gas Turbine Guidelines: Rotating Blade Temperature Measurement System (BTMS): Durability Surveillance at Potomac Electric P ower Company's Station H  

Science Conference Proceedings (OSTI)

The blade scans performed by EPRI's Blade Temperature Measurement System (BTMS) represent an important source of blade metal temperature data. These advanced gas turbine guidelines describe the design, installation, and operation of the BTMS in a utility power plant. The guidelines include an analysis of blade temperature scans as well as a summary of lessons learned.

1999-04-26T23:59:59.000Z

433

NIHR Carbon Guidelines -FAQs 1. Why do the guidelines address only the principles of good research?  

E-Print Network (OSTI)

NIHR Carbon Guidelines - FAQs 1. Why do the guidelines address only the principles of good research? The guidelines outline strategies to reduce the carbon emissions from health research. Because most publicly to reduce carbon emissions would also reduce the carbon emissions from health research. However, strategies

Diggle, Peter J.

434

Comparison of Methods for Evaluating Nuclear Thermal Propulsion Tie-Tube Designs  

Science Conference Proceedings (OSTI)

One of the fundamental structural components in a nuclear thermal rocket design is the tie tube. Proper cooling and flow modeling is important both for the structural integrity of the reactor core and for proper design of downstream components that operate on the hydrogen exiting the tie tube. Two models have been developed. The first is a spreadsheet-based tool designed for sizing tie-tube components, considering mechanical stress and strain limits, deposited moderator power, thermal expansion along the flow path, and conduction from adjacent fuel blocks. The second is a three-dimensional SINDA/FLUINT model used as a benchmark, containing a complete finite-element fuel block and a 1/6th tie-tube model. This paper discusses the performance of both models, as well as the advantages and limitations of each.

Kapernick, Richard J. [Nuclear Systems Design Group, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Dixon, David D. [Nuclear Systems Design Group, Los Alamos National Laboratory, Los Alamos, NM 87545 (United States); Department of Nuclear Engineering, University of Tennessee, Knoxville, TN 37996 (United States)

2008-01-21T23:59:59.000Z

435

Severe accident approach - final report. Evaluation of design measures for severe accident prevention and consequence mitigation.  

Science Conference Proceedings (OSTI)

An important goal of the US DOE reactor development program is to conceptualize advanced safety design features for a demonstration Sodium Fast Reactor (SFR). The treatment of severe accidents is one of the key safety issues in the design approach for advanced SFR systems. It is necessary to develop an in-depth understanding of the risk of severe accidents for the SFR so that appropriate risk management measures can be implemented early in the design process. This report presents the results of a review of the SFR features and phenomena that directly influence the sequence of events during a postulated severe accident. The report identifies the safety features used or proposed for various SFR designs in the US and worldwide for the prevention and/or mitigation of Core Disruptive Accidents (CDA). The report provides an overview of the current SFR safety approaches and the role of severe accidents. Mutual understanding of these design features and safety approaches is necessary for future collaborations between the US and its international partners as part of the GEN IV program. The report also reviews the basis for an integrated safety approach to severe accidents for the SFR that reflects the safety design knowledge gained in the US during the Advanced Liquid Metal Reactor (ALMR) and Integral Fast Reactor (IFR) programs. This approach relies on inherent reactor and plant safety performance characteristics to provide additional safety margins. The goal of this approach is to prevent development of severe accident conditions, even in the event of initiators with safety system failures previously recognized to lead directly to reactor damage.

Tentner, A. M.; Parma, E.; Wei, T.; Wigeland, R.; Nuclear Engineering Division; SNL; INL

2010-03-01T23:59:59.000Z

436

Preliminary Evaluation of an Energy & Reserve Co-optimization Market Design  

Science Conference Proceedings (OSTI)

This report documents the background and motivation for the revision of the reserve market design in the service area of the Independent System Operator New England (ISO-NE). Due to previous experience with initial reserve markets that exposed noticeable market design flaws, the ISO embarked on a program to revise the two market elements that are analyzed in this report. The two market elements are a Forward Reserve Market and a co-optimized energy and reserve market in real time. The project to analyze ...

2008-12-01T23:59:59.000Z

437

Guideline for Procurement of Gas Turbine Parts: Casting Quality and Inspection  

Science Conference Proceedings (OSTI)

EPRI has previously developed a series of Parts Procurement Guides to help engine owners assess alternate component designs and obtain competitive quotes from non-OEM aftermarket suppliers offering replacement airfoils for the more widely used gas turbine models. These procurement guidelines provide owners with the requirements needed to procure buckets and nozzles for their specific gas turbine model. The guidelines reference different inspection standards published by organizations such as American Soc...

2010-12-23T23:59:59.000Z

438

Condensate Polishing Guidelines for Pressurized Water Reactor and Boiling Water Reactor Plants - 2004 Revision  

Science Conference Proceedings (OSTI)

Successful condensate polishing allows more reliable operation of nuclear units by maintaining control of ionic and particulate impurity transport to the pressurized water reactor (PWR) steam generators and the boiling water reactor (BWR) and recirculation system. This report presents revisions of EPRI's 1997 nuclear industry consensus guidelines for the design and operation of deep bed and filter demineralizer condensate polishers. These guidelines are consistent with the 2000 revisions of EPRI's "BWR W...

2004-03-16T23:59:59.000Z

439

EIA-Voluntary Reporting of Greenhouse Gases Program - Reporting Guidelines  

U.S. Energy Information Administration (EIA) Indexed Site

Reporting Guidelines Reporting Guidelines Voluntary Reporting of Greenhouse Gases Program Reporting Guidelines The purpose of the guidelines is to establish the procedures and requirements for filing voluntary reports, and to ensure that the annual reports of greenhouse gas emissions, emission reductions, and sequestration activities submitted by corporations, government agencies, non-profit organizations, households, and other private and public entities to submit are complete, reliable, and consistent. Over time, it is anticipated that these reports will provide a reliable record of the contributions reporting entities have made toward reducing their greenhouse gas emissions. General Guidelines General Guidelines Technical Guidelines Technical Guidelines Appendices to the Technical Guidelines:

440

Reliability evaluation and optimal design in heterogeneous multi-state series-parallel systems  

Science Conference Proceedings (OSTI)

This paper addresses the heterogeneous redundancy allocation problem in multi-state series-parallel reliability structures with the objective to minimize the total cost of system design satisfying the given reliability constraint and the consumer load ... Keywords: Ant colony optimization, Heterogeneous redundancy optimization, Multi-state, Series-parallel system

Vikas K. Sharma; Manju Agarwal; Kanwar Sen

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Evaluation of body sensor network platforms: a design space and benchmarking analysis  

Science Conference Proceedings (OSTI)

Body Sensor Networks (BSNs) consist of sensor nodes deployed on the human body for health monitoring. Each sensor node is implemented by interfacing a physiological sensor with a sensor platform consisting of components such as microcontroller, radio ... Keywords: benchmark, body sensor networks, design space, hardware systems, system performance, wearable BSNs

Sidharth Nabar; Ayan Banerjee; Sandeep K. S. Gupta; Radha Poovendran

2010-10-01T23:59:59.000Z

442

Dynamic picking system for 3D seismic data: Design and evaluation  

Science Conference Proceedings (OSTI)

In the framework of data interpretation for petroleum exploration, this paper contributes two contributions for visual exploration aiming to manually segment surfaces embedded in volumetric data. Resulting from a user-centered design approach, the first ... Keywords: 3D interaction, Dynamic picking, Focus+context, Manual segmentation, Projective slice, Structural interpretation, Volumetric data

Pierre Salom; Remi Megret; Marc Donias; Yannick Berthoumieu

2009-07-01T23:59:59.000Z

443

Evaluation of critical materials in five additional advance design photovoltaic cells  

DOE Green Energy (OSTI)

The objective of this study is to identify potential material supply constraints due to the large-scale deployment of five advanced photovoltaic (PV) cell designs, and to suggest strategies to reduce the impacts of these production capacity limitations and potential future material shortages. The Critical Materials Assessment Program (CMAP) screens the designs and their supply chains and identifies potential shortages which might preclude large-scale use of the technologies. The results of the screening of five advanced PV cell designs are presented: (1) indium phosphide/cadmium sulfide, (2) zinc phosphide, (3) cadmium telluride/cadmium sulfide, (4) copper indium selenium, and (5) cadmium selenide photoelectrochemical. Each of these five cells is screened individually assuming that they first come online in 1991, and that 25 Gwe of peak capacity is online by the year 2000. A second computer screening assumes that each cell first comes online in 1991 and that each cell has a 5 GWe of peak capacity by the year 2000, so that the total online capacity for the five cells is 25 GWe. Based on a review of the preliminary baseline screening results, suggestions were made for varying such parameters as the layer thickness, cell production processes, etc. The resulting PV cell characterizations were then screened again by the CMAP computer code. The CMAP methodology used to identify critical materials is described; and detailed characterizations of the advanced photovoltaic cell designs under investigation, descriptions of additional cell production processes, and the results are presented. (WHK)

Smith, S.A.; Watts, R.L.; Martin, P.; Gurwell, W.E.

1981-02-01T23:59:59.000Z

444

DeDe: design and evaluation of a context-enhanced mobile messaging system  

Science Conference Proceedings (OSTI)

This paper presents the design, implementation and validation of an enhanced mobile phone messaging system (DeDe), allowing the sender to define the context in which the message will be delivered to the recipient. A field trial among a socially tight ... Keywords: context, field trial, location-based messaging, mediated communication, mobile messaging

Younghee Jung; Per Persson; Jan Blom

2005-04-01T23:59:59.000Z

445

Southwestern Public Service Company Solar Repowering Program. Volume 1. Conceptual design and evaluation. Final technical report  

DOE Green Energy (OSTI)

The detailed conceptual design, subsystem characteristics, economic analysis, development plan, and user's assessment of repowering Southwest Public Service Company's Plant X located south of Amarillo, Texas, with a tower focus power plant are presented. The plant will utilize liquid sodium heat transfer fluids, thermal storage tanks, and a steam generator/turbine. Detailed economic and cost data are included. (WHK)

Not Available

1980-07-01T23:59:59.000Z

446

MANUFACTURING COMPLEXITY EVALUATION AT THE DESIGN STAGE FOR BOTH MACHINING AND LAYERED MANUFACTURING  

E-Print Network (OSTI)

and an additive process. Manufacturability indexes are calculated at the tool design stage, these indexes provide an accurate view of which areas of the tool will advantageously be machined or manufactured by an additive], but manufacturing features for additive technologies are still under development [5]. Furthermore, for free

Paris-Sud XI, Université de

447

Market Transformation: A Practical Guide to Designing and Evaluating Energy Efficient Programs  

Science Conference Proceedings (OSTI)

One widely accepted paradigm for energy efficiency marketing is called market transformation. This theory holds that energy efficiency programs should be designed to transform markets by reducing market barriers, thus allowing energy efficient products and services to become widely available and adopted by energy customers. Market transformation theory also states that these market changes should become persistent and self-sustaining.

2001-04-19T23:59:59.000Z

448

Evaluation of Some Ground Truth Designs for Satellite Estimates of Rain Rate  

Science Conference Proceedings (OSTI)

In this paper point gauge measurements are analyzed as part of a ground truth design to validate satellite retrieval algorithms at the field-of-view spatial level (typically about 20 km). Even in the ideal case the ground and satellite ...

Eunho Ha; Gerald R. North; Chulsang Yoo; Kyung-Ja Ha

2002-01-01T23:59:59.000Z

449

Design and testbed evaluation of RDMA-based middleware for high-performance data transfer applications  

Science Conference Proceedings (OSTI)

Providing high-speed data transfer is vital to various data-intensive applications supported by data center networks. We design a middleware layer of high-speed communication based on Remote Direct Memory Access (RDMA) that serves as the common substrate ... Keywords: Distributed systems, Middleware, Remote Direct Memory Access

Yufei Ren, Tan Li, Dantong Yu, Shudong Jin, Thomas Robertazzi

2013-07-01T23:59:59.000Z

450

Preliminary evaluation of hermetic JT/LJT/R P connector socket contact design  

SciTech Connect

This report presents a precursory examination of a number of issues pertaining to socket contacts in hermetic connectors. The principal issues addressed are high-contact resistance and contact chatter (circuit discontinuities). Efforts examining the characteristics of the existing socket contact design, the possibility of connector/contact rework, quick-fix solutions, and contact redesigns are summarized.

Baca, J.R.F.

1991-10-01T23:59:59.000Z

451

Emergency Management Guideline for Fossil Generating Stations  

Science Conference Proceedings (OSTI)

This EPRI guideline builds on industry experience, including lessons learned during the severe U.S. hurricane seasons of 2004 and 2005, to present a framework for the development of an emergency management program at a generating station. The guideline is specifically intended for fossil plants, although much of the information is relevant to other types of facilities.

2008-03-20T23:59:59.000Z

452

Duke Edwardsport Generic Design Specification  

Science Conference Proceedings (OSTI)

This generic design specification (GDS) is sponsored by the CoalFleet for Tomorrow program of the Electric Power Research Institute (EPRI). The CoalFleet Integrated Gasification Combined Cycle (IGCC) Design Guidelines Experts Group produced this report, which is based on available public sources and information. The CoalFleet IGCC Design Guidelines Experts Group consists of more than 10 IGCC experts, including independent consultants and EPRI staff.

2011-01-20T23:59:59.000Z

453

Guidelines for Reduced Seismic Loads to Assess Temporary Conditions in Nuclear Power Plants  

Science Conference Proceedings (OSTI)

Utilities do not have uniform guidelines and criteria to treat plant temporary conditions (TCs) or planned changes to safety-related systems. Regulatory review and acceptance criteria and guidelines tend to be overly conservative, leading to costly measures. This report proposes a risk-informed procedure for evaluating TCs using reduced seismic loads and current licensing basis allowables that reduces plant operation and maintenance (O&M) costs, shortens plant outages, and reduces personnel radiation exp...

1998-09-10T23:59:59.000Z

454

Aging Management Guidelines for Commercial Nuclear Power Plants -- Electrical and Mechanical Penetrations  

Science Conference Proceedings (OSTI)

As part of the application process for license renewal, nuclear utilities must perform an evaluation to confirm that they have appropriately considered aging effects on plant components within the scope of the License Renewal Rule. This report provides guidelines for managing relevant degradation mechanisms applicable to electrical and mechanical penetrations in nuclear power plants. Use of these guidelines will provide utilities with a basis for verifying that effective methods for managing age-related ...

2002-04-25T23:59:59.000Z

455

Model Based Structural Evaluation & Design of Overpack Container for Bag-Buster Processing of TRU Waste Drums  

Science Conference Proceedings (OSTI)

This paper describes a materials and computational model based analysis utilized to design an engineered “overpack” container capable of maintaining structural integrity for confinement of transuranic wastes undergoing the cryo-vacuum stress based “Bag-Buster” process and satisfying DOT 7A waste package requirements. The engineered overpack is a key component of the “Ultra-BagBuster” process/system being commercially developed by UltraTech International for potential DOE applications to non-intrusively breach inner confinement layers (poly bags/packaging) within transuranic (TRU) waste drums. This system provides a lower cost/risk approach to mitigate hydrogen gas concentration buildup limitations on transport of high alpha activity organic transuranic wastes. Four evolving overpack design configurations and two materials (low carbon steel and 300 series stainless) were considered and evaluated using non-linear finite element model analyses of structural response. Properties comparisons show that 300-series stainless is required to provide assurance of ductility and structural integrity at both room and cryogenic temperatures. The overpack designs were analyzed for five accidental drop impact orientations onto an unyielding surface (dropped flat on bottom, bottom corner, side, top corner, and top). The first three design configurations failed the bottom and top corner drop orientations (flat bottom, top, and side plates breached or underwent material failure). The fourth design utilized a protruding rim-ring (skirt) below the overpack’s bottom plate and above the overpack’s lid plate to absorb much of the impact energy and maintained structural integrity under all accidental drop loads at both room and cryogenic temperature conditions. Selected drop testing of the final design will be required to confirm design performance.

D. T. Clark; A. S. Siahpush; G. L. Anderson

2004-07-01T23:59:59.000Z

456

ESARDA paper, IRSN-SCM SA, May 2007 Implementation of an experimental design to evaluate  

E-Print Network (OSTI)

ERDC/ELTR-12-25 Army Range Technology Program Large-Scale Physical Separation of Depleted Uranium-Scale Physical Separation of Depleted Uranium from Soil Steven Larson, Victor Medina, John Ballard, Chris Griggs) at Yuma Proving Ground (YPG) to evaluate this technique for removal of depleted uranium (DU) metal from

457

Design and evaluation of a smart home voice interface for the elderly: acceptability and objection aspects  

Science Conference Proceedings (OSTI)

Smart homes equipped with ambient intelligence technology constitute a promising direction to enable the growing number of elderly to continue to live in their own home as long as possible. However, this calls for technological solutions that suit their ... Keywords: Gerontechnology, Smart home, Ubiquitous computing, User evaluation, Voice interface

François Portet; Michel Vacher; Caroline Golanski; Camille Roux; Brigitte Meillon

2013-01-01T23:59:59.000Z

458

DESIGN AND EVALUATION OF A SAMPLER FOR MEASURING THE NEAR-BOTTOM VERTICAL DISTRIBUTION OF  

E-Print Network (OSTI)

conducted with the sampler dealt with evaluations of mesh size and tickler chain. Experiments indicated doubled when a tickler chain was used. The sampler may have application to both shrimp biologists organisms; and (4) a tickler chain on shrimp catch rate and vertical distribution. 1 Northwest Fisheries

459

EVALUATION OF A PROTOTYPE SOLAR AWNING A prototype solar awning has been designed and installed on  

E-Print Network (OSTI)

students and faculty can perform tests and experi- ments on a real solar awning -- daylighting system awning system would meet or exceed the recommended daylight factor levels for most common commercial to evaluate of the performance of this building integrated photovoltaic (BIPV) system. Adding daylighting

Oregon, University of

460

State Energy Assurance Guidelines | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

State Energy Assurance Guidelines State Energy Assurance Guidelines State Energy Assurance Guidelines The State Energy Assurance Guidelines were developed by the National Association of State Energy Officials (NASEO) with the assistance of the National Association of Regulatory Utility Commissioners (NARUC) under the direction of the U.S. Department of Energy's Office of Electricity Delivery and Energy Reliability (OE). The guidelines integrate the lessons learned from responding to energy emergencies in recent years and from the dialogue that has occurred at conferences, exercises and meetings on energy assurance. They encompass many topics that states may wish to consider incorporating into their plans. Foremost among these is how energy assurance can improve: planning and responding quickly and effectively to

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

IPCC Inventory Guidelines LULUCF | Open Energy Information  

Open Energy Info (EERE)

IPCC Inventory Guidelines LULUCF IPCC Inventory Guidelines LULUCF Jump to: navigation, search Tool Summary Name: IPCC Inventory Guidelines LULUCF Agency/Company /Organization: World Meteorological Organization, United Nations Environment Programme Sector: Land Focus Area: Forestry, Agriculture Topics: GHG inventory Resource Type: Guide/manual, Lessons learned/best practices Website: www.ipcc-nggip.iges.or.jp/public/gpglulucf/gpglulucf_contents.html IPCC Inventory Guidelines LULUCF Screenshot References: IPCC Inventory Guidelines LULUCF[1] "This report on Good Practice Guidance for Land Use, Land-Use Change and Forestry (GPG-LULUCF) is the response to the invitation by the United Nations Framework Convention on Climate Change (UNFCCC) to the Intergovernmental Panel on Climate Change (IPCC) to develop good practice

462

SLAC Lightsource User Access Guidelines and Agreement  

NLE Websites -- All DOE Office Websites (Extended Search)

Lightsource User Access Guidelines & Agreement Lightsource User Access Guidelines & Agreement August 3, 2011 SLAC-I-030-306-001-00-R002 1 SLAC Lightsource User Access Guidelines and Agreement LCLS / SSRL User Research Administration approval (signature/date): LCLS Safety Office approval (signature/date): SSRL Safety Office approval (signature/date): XFO Operations approval (signature/date): Revision Record Revision Date Revised Section(s) Affected Description of Change R001 October 4 th , 2010 User Form Updated SLAC Lightsource User Access Agreement Form R000 Sept 14, 2009 Original Release SLAC Lightsource User Access Guidelines & Agreement August 3, 2011 SLAC-I-030-306-001-00-R002 1 SLAC LIGHTSOURCE USER ACCESS GUIDELINES & AGREEMENT Introduction Welcome to SSRL and LCLS, SLAC's lightsource user facilities. We hope that your stay here will be

463

Evaluation of tubular reactor designs for supercritical water oxidation of U.S. Department of Energy mixed waste  

Science Conference Proceedings (OSTI)

Supercritical water oxidation (SCWO) is an emerging technology for industrial waste treatment and is being developed for treatment of the US Department of Energy (DOE) mixed hazardous and radioactive wastes. In the SCWO process, wastes containing organic material are oxidized in the presence of water at conditions of temperature and pressure above the critical point of water, 374 C and 22.1 MPa. DOE mixed wastes consist of a broad spectrum of liquids, sludges, and solids containing a wide variety of organic components plus inorganic components including radionuclides. This report is a review and evaluation of tubular reactor designs for supercritical water oxidation of US Department of Energy mixed waste. Tubular reactors are evaluated against requirements for treatment of US Department of Energy mixed waste. Requirements that play major roles in the evaluation include achieving acceptable corrosion, deposition, and heat removal rates. A general evaluation is made of tubular reactors and specific reactors are discussed. Based on the evaluations, recommendations are made regarding continued development of supercritical water oxidation reactors for US Department of Energy mixed waste.

Barnes, C.M.

1994-12-01T23:59:59.000Z

464

Fuel Design Evaluation Handbook: Tools for Assessing Fuel and Core Component Performance  

Science Conference Proceedings (OSTI)

The overall objective of this report is to provide a set of concise technical performance considerations for nuclear fuel and core components that, if effectively addressed, will reduce the number of fuel and core component related operational issues, increase fuel reliability to achieve and sustain operation with zero defects, and allow increases in fuel burnup to be achieved in future designs with improved margins to thermal and mechanical limits. The technical considerations and recommendations in thi...

2011-01-31T23:59:59.000Z

465

Technical Evaluation of the Hitachi Resource-Renewable BWR (RBWR) Design Concept  

Science Conference Proceedings (OSTI)

The capabilities of an advanced Resource-Renewable Boiling Water Reactor (RBWR) developed by Hitachi Ltd. have been analyzed by an Electric Power Research Institute- (EPRI-) organized team from three universities, using largely independent methods. The analysis has shown that the two variants of the RBWR design that were studied can represent potential alternatives to sodium-cooled fast reactors. The fuel self-sustaining RBWR-AC, which has a breeding ratio slightly greater than 1.0, can be an alternative...

2012-04-30T23:59:59.000Z

466

Strategy Guideline: Quality Management in Existing Homes; Cantilever Floor Example  

SciTech Connect

This guideline is designed to highlight the QA process that can be applied to any residential building retrofit activity. The cantilevered floor retrofit detailed in this guideline is included only to provide an actual retrofit example to better illustrate the QA activities being presented. The goal of existing home high performing remodeling quality management systems (HPR-QMS) is to establish practices and processes that can be used throughout any remodeling project. The research presented in this document provides a comparison of a selected retrofit activity as typically done versus that same retrofit activity approached from an integrated high performance remodeling and quality management perspective. It highlights some key quality management tools and approaches that can be adopted incrementally by a high performance remodeler for this or any high performance retrofit. This example is intended as a template and establishes a methodology that can be used to develop a portfolio of high performance remodeling strategies.

Taggart, J.; Sikora, J.; Wiehagen, J.; Wood, A.

2011-12-01T23:59:59.000Z

467

Design and evaluation of a two-phase turbine for low quality steam--water mixtures  

DOE Green Energy (OSTI)

A new two-phase turbine was designed and built for testing in the laboratory, using a low quality steam-water mixture as a working fluid. The measured performance compares well with performance predictions of a numerical model of the expander. Details of the selection of the type of expander are given. The design of an experimental expander for use in a clean two-phase flow laboratory experiment and the development of a numerical model for performance analysis and extrapolations are described. Experiments including static cascade performance with two-phase fluid, disk friction and windage measurements, and two-phase performance measurements of the experimental expander are reported. Comparisons of the numerical model and experimental results, and the prediction of the performance of an advanced design, indicating how performance improvements can be achieved, are also included. An engine efficiency of 23 percent for a single-nozzle test was measured. Full admission performance, based upon the numerical model and achievable nozzle thrust coefficients indicate that an engine efficiency of between 38 and 48 percent can be realized with present technology. If maximum liquid removal loss is assumed, this performance range is predicted to be 38 to 41 percent. Droplet size reduction and the development and implementation of enhanced two-phase flow analysis techniques should make it possible to achieve the research goal of 70 percent engine efficiency.

Comfort, W.J. III

1977-05-16T23:59:59.000Z

468

Design and demonstration of heat pipe cooling for NASP and evaluation of heating methods at high heating rates  

SciTech Connect

An evaluation of two heating methods for demonstration of NASP leading edge heat pipe technology was conducted. The heating methods were and rf induction heated plasma jet and direct rf induction. Tests were conducted to determine coupling from the argon plasma jet on a surface physically similar to a heat pipe. A molybdenum tipped calorimeter was fabricated and installed in an rf induction heated plasma jet for the test. The calorimetric measurements indicated a maximum power coupling of approximately 500 W/cm{sup 2} with the rf plasma jet. The effect of change in gas composition on the heating rate was investigated using helium. An alternative to the plasma heating of a heat pipe tip, an rf concentrator was evaluated for coupling to the hemispherical tip of a heat pipe. A refractory metal heat pipe was designed, fabricated, and tested for the evaluation. The heat pipe was designed for operation at 1400 to 1900 K with power input to 1000 W/cm{sup 2} over a hemispherical nose tip. Power input of 800 W/cm{sup 2} was demonstrated using the rf concentrator. 2 refs., 13 figs.

Merrigan, M.A.; Sena, J.T.

1989-01-01T23:59:59.000Z

469

Reference Design Description and Cost Evaluation for Compressed Air Energy Storage Systems  

Science Conference Proceedings (OSTI)

Compressed-air energy storage (CAES) is a valuable solution for mitigating the current challenges of renewable-power variability, facilitating higher renewable penetration levels, enhancing grid reliability, and improving the utilization of transmission and generation assets. However, capital costs play a critical role in evaluating the overall CAES value proposition, at least relative to direct-market revenues (energy and ancillary services). Although the first U.S. CAES plant in Alabama was built at co...

2011-12-21T23:59:59.000Z

470

Evaluation of injector location and nozzle design in a direct-injection hydrogen research engine.  

DOE Green Energy (OSTI)

The favorable physical properties of hydrogen (H{sub 2}) make it an excellent alternative fuel for internal combustion (IC) engines and hence it is widely regarded as the energy carrier of the future. Hydrogen direct injection provides multiple degrees of freedom for engine optimization and influencing the in-cylinder combustion processes. This paper compares the results in the mixture formation and combustion behavior of a hydrogen direct-injected single-cylinder research engine using two different injector locations as well as various injector nozzle designs.

Wallner, T.; Nande, A. M.; Naber, J.; Energy Systems; Michigan Technological Univ.

2008-06-01T23:59:59.000Z

471

Evaluation of Alternative IGCC Plant Designs for High Availability and Near Zero Emissions  

Science Conference Proceedings (OSTI)

This report examines the historical reliability and availability data of solids-fed integrated gasification combined cycle (IGCC) power plants and describes how these data can be used to analyze design options meant to improve the availability of new IGCCs. It also looks at the technical and economic impacts of adding a Selective Catalytical Reduction (SCR) system to an IGCC. Adding an SCR will result in a coal-based power plant with an emissions profile that is very close to a natural gas fired combined...

2005-12-20T23:59:59.000Z

472

Evaluation of cobalt sources in Westinghouse-designed three- and four-loop plants. Final report  

SciTech Connect

Sources of cobalt input in two typical Westinghouse-designed three- and four-loop plants are identified. Quantification of the sources was based on a detailed analysis of the construction materials. The best available information was used to establish the corrosion and wear release rates. This analysis concludes that approximately 70% of the cobalt input arises from corrosion release of Inconel steam generator tubing. Corrosion and wear of high-cobalt alloys account for about 25%. Recommendations are made concerning cobalt reduction options based on a cost-benefit analysis.

Bergmann, C.A.

1982-10-01T23:59:59.000Z

473

Evaluating Utility Executives' Perceptions of Smart Grid Costs, Benefits and Adoption Plans To Assess Impacts on Building Design and Construction  

E-Print Network (OSTI)

Smart Grid technology is likely to be implemented in various magnitudes across utilities in the near future. To accommodate these technologies significant changes will have to be incorporated in building design construction and planning. This research paper attempts to evaluate public utility executives’ plans to adopt smart grid technologies and to assess timing of smart grid impacts on future design and construction practices. Telephone survey was the data collection method used to collect information from executives at cooperative and municipal utilities. The study focuses on small and medium utilities with more than five thousand customers and fewer than one hundred thousand customers. A stratified random sampling approach was applied and sample results for fifty-nine survey responses were used to predict the timing of smart grid implementation and the timing of smart grid impacts on future design and construction practices. Results of this research indicate that design and construction professionals should already be developing knowledge and experience to accommodate smart grid impacts on the built environment.

Rao, Ameya Vinayak

2010-08-01T23:59:59.000Z

474

Design and Evaluation of a High Temperature Burner Duct Recuperator System  

E-Print Network (OSTI)

"The Babcock & Wilcox Company (B&W) has completed a program to design, construct, install, and field test a ceramic-based high-temperature burner-duct-recuperator (HTBDR) in an industrial setting. The unit was capable of operating in corrosive, high temperature (2250oF) flue gas streams. The HTBDR was successfully tested in a steel soaking pit at B&W's Tubular Products Division in Koppel, Pennsylvania. The ceramic stage consisted of 50 bayonet style ceramic tube-in-tube assemblies supported by an insulated metallic tubesheet and sealed with a ceramic fiber product. The heat exchanger was designed to take maximum advantage of radiation heat transfer, minimize pressure drops on both the air and flue sides, and minimize thermal stresses and fouling. Modeling of the bayonet assemblies determined the outer-to-inner tube spacing to optimize the air-side pressure drop and heat transfer within the tubes. During the 1400 hour operation prior to plant closing, the ceramic stage performed well with no material related problems or air-to-flue leakage. Maximum preheat air produced was 1425°F with a flue gas temperature of 2250oF. Measured fuel savings of 17-24% were obtained over the previous recuperated (metallic heat exchanger) system. This projects a savings of 41% for an unrecuperated furnace. A simple payback analysis indicated acceptable payback for installation in unrecuperated furnaces but unacceptable payback for recuperated furnaces at today's low gas prices."

Parks, W. P.; DeBellis, C. L.; Kneidel, K.

1988-09-01T23:59:59.000Z

475

Design, synthesis, and evaluation of polyhydroxamate chelators for selective complexation of actinides  

SciTech Connect

Specific chelating polymers targeted for actinides have much relevance to problems involving remediation of nuclear waste. Goal is to develop polymer supported, ion specific extraction systems for removing actinides and other hazardous metal ions from wastewaters. This is part of an effort to develop chelators for removing actinide ions such as Pu from soils and waste streams. Selected ligands are being attached to polymeric backbones to create novel chelating polymers. These polymers and other water soluble and insoluble polymers have been synthesized and are being evaluated for ability to selectively remove target metal ions from process waste streams.

Gopalan, A.; Jacobs, H.; Koshti, N.; Stark, P.; Huber, V.; Dasaradhi, L.; Caswell, W. [New Mexico State Univ., Las Cruces, NM (United States); Smith, P.; Jarvinen, G. [Los Alamos National Lab., NM (United States)

1995-08-01T23:59:59.000Z

476

Northeast Home Heating Oil Reserve - Guidelines for Release ...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Guidelines for Release Northeast Home Heating Oil Reserve - Guidelines for Release Petroleum Reserves Strategic Petroleum Reserve Heating Oil Reserve Naval Reserves International...

477

Weatherization and Intergovernmental Program: Guidelines for Home Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Guidelines for Home Energy Professionals to someone by E-mail Guidelines for Home Energy Professionals to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on Facebook Tweet about Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on Twitter Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on Google Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on Delicious Rank Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on Digg Find More places to share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on AddThis.com... Plans, Implementation, & Results Weatherization Assistance Program