1

SEISMIC DESIGN EVALUATION GUIDELINES FOR BURIED PIPING FOR THE DOE HLW FACILITIES'  

Office of Scientific and Technical Information (OSTI)

6 1 6 1 7 1 1 SEISMIC DESIGN EVALUATION GUIDELINES FOR BURIED PIPING FOR THE DOE HLW FACILITIES' Chi-Wen Lin Consultant, Martinez, CA George Antaki Westinghouse Savannah River Co., Aiken, SC Kamal Bandyopadhyay Brookhaven National Lab., Upton, NY ABSTRACT This paper presents the seismic design and evaluation guidelines for underground piping for the Department of Energy (DOE) High-Level-Waste (HLW) Facilities. The underground piping includes both single and double containment steel pipes and concrete pipes with steel lining, with particular emphasis on the double containment piping. The design and evaluation guidelines presented in this paper follow the generally accepted beam-on-elastic- foundation analysis principle and the inertial response calculation method, respectively, for piping directly

2

Design Guidelines INTRODUCTION  

E-Print Network [OSTI]

Design Guidelines March 2005 #12;INTRODUCTION INTENT The Boise State University (BSU) Design Guidelines are intended for the use by design professionals as a resource to facilitate the design of BSU design, construction and operation. The intent of these guidelines is to provide the information

Barrash, Warren

3

DESIGN GUIDELINE SUMMARY  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 Rev. 3 3 Rev. 3 August 2003 Rev. June 2004 Design Guideline Summary Based on the GEOVISION Report of Stanford Linear Accelerator Tunnel Vibration Measurements Parsons Pasadena, CA For Stanford Linear Accelerator Center Stanford University Stanford, CA Abstract: This summary report is provided in order to suggest how the measurement data from the GEOVision report might be used by SLAC for their proposed Next Linear Collider facility. See the referenced report "Stanford Linear Accelerator Tunnel Vibration Measurements, Conducted at MTA Universal Subway Station, North Hollywood, California", by GEOVision dated July 28, 2003. The following discussions are an attempt to determine an upper bound methodology that can be used for design purposes. The data in the

4

SECTION FOUR Site Design Guidelines Bicycle Systems  

E-Print Network [OSTI]

SECTION FOUR Site Design Guidelines Bicycle Systems 26 4, the following should be considered when designa ng bicycle routes on roadways: Vehicular speed limits; SECTION FOUR Site Design Guidelines Bicycle Systems 27 4.2 BIKE LANES Bike lanes

Duchowski, Andrew T.

5

DESIGN GUIDELINES FOR FACILITIES CONSTRUCTION  

E-Print Network [OSTI]

Drafting Standards DG 010000.22 Drawing Content and Submittal Requirements DG 010000.23 University -- HEATING, VENTILATING AND AIR CONDITIONING DG 230000.10 Procedures, Design Standards, and Design Criteria (HVAC) DG 230000.20 Materials, Equipment and Methods (HVAC) DG 230913 Instrumentation and Control

Farritor, Shane

6

Design guidelines and evaluation of an ergonomic chair feature capable of providing support to forward-leaning postures  

E-Print Network [OSTI]

female to the 95th percentile male, to establish the range of potential forward-leaning postures. The design of a Support-Arm for use with current ergonomic chairs was discussed and design feature specifications were then provided. A Latin Square...

Stevens, Edward Martin

2005-02-17T23:59:59.000Z

7

Building design guidelines for solar energy technologies  

SciTech Connect (OSTI)

There are two main objectives to this publication. The first is to find out the communalities in the experience gained in previous studies and in actual applications of solar technologies in buildings, residential as well as nonresidential. The second objective is to review innovative concepts and products which may have an impact on future developments and applications of solar technologies in buildings. The available information and common lessons were collated and presented in a form which, hopefully, is useful for architects and solar engineers, as well as for teachers of solar architecture'' and students in Architectural Schools. The publication is based mainly on the collection and analysis of relevant information. The information included previous studies in which the performance of solar buildings was evaluated, as well as the personal experience of the Author and the research consultants. The state of the art, as indicated by these studies and personal experience, was summarized and has served as basis for the development of the Design Guidelines. In addition to the summary of the state of the art, as was already applied in solar buildings, an account was given of innovative concepts and products. Such innovations have occurred in the areas of thermal storage by Phase Change Materials (PCM) and in glazing with specialized or changeable properties. Interesting concepts were also developed for light transfer, which may enable to transfer sunlight to the core areas of large multi story nonresidential buildings. These innovations may have a significant impact on future developments of solar technologies and their applications in buildings. 15 refs., 19 figs., 3 tabs.

Givoni, B.

1989-01-01T23:59:59.000Z

8

Guidelines in Wave Energy Conversion System Design  

E-Print Network [OSTI]

This paper presents an investigational study on wave energy converters (WECs). The types of WEC available from the market are studied first. The design considerations for implementing a WEC in the Gulf of Mexico (GOM) are then evaluated...

Guiberteau, K. L.; Liu, Y.; Lee, J.; Kozman, T.

2014-01-01T23:59:59.000Z

9

Guidelines for Evaluation of Nuclear Facility Training Programs  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Guidelines for Evaluation of Nuclear Facility Training Programs establish objectives and criteria for evaluating nuclear facility training programs. The guidance in this standard provides a framework for the systematic evaluation of training programs at nuclear facilities and is based, in part, on established criteria for Technical Safety Appraisals, Tiger Team Assessments, commercial nuclear industry evaluations, and the DOE Training Accreditation Program.

1995-11-22T23:59:59.000Z

10

Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

for licensing technologies Savannah River Nuclear Solutions Savannah River National Laboratory We're pleased you've chosen to submit a request for a Savannah River Nuclear Solutions license. We look forward to helping you launch a new product. Our License Application comes in two parts. You may submit the Intent to License first, followed by the more detailed Business Plan. Or, you may submit both at the same time. These guidelines, which may or may not apply in all circumstances, describe the information we need to evaluate your request. Please take a moment to determine which of these guidelines apply to you. If you have any questions, please don't hesitate to call us. Cover page Please provide your company name, address, phone, fax, e-mail and Web site. Also include the name of a contact

11

Design guidelines for downtown shopping centers  

E-Print Network [OSTI]

This thesis focuses on urban design issues germane to downtown shopping center design. The underlying concept is that, all new downtown shopping centers should attempt to build upon the existing fabric in such a way as to ...

McGhee, Billy Kevin

1987-01-01T23:59:59.000Z

12

Guidelines for Engineering, Design, and Inspection Costs  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

Engineering, design, and inspection (ED&I) activities begin with the preliminary design (Title I). Pre-Title I activities are not considered part of the ED&I activities. Architectural/Engineering (A/E) activities are part of the ED&I activities. A/E activities are services that are an integral part of the production and delivery of the design plans, specifications, and drawings. This chapter defines ED&I and A/E activities and discusses how to estimate and track them.

1997-03-28T23:59:59.000Z

13

Design guidelines for optical resonator biochemical sensors  

E-Print Network [OSTI]

In this paper, we propose a design tool for dielectric optical resonator-based biochemical refractometry sensors. Analogous to the widely accepted photodetector figure of merit, the detectivity D*, we introduce a new sensor ...

Kimerling, Lionel C.

14

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities  

Broader source: Energy.gov [DOE]

Guidelines and criteria describe meeting requirements within Section 432 of the Energy Independence and Security Act of 2007 (EISA 2007), including defining facilities covered by the provision, designating facility energy managers to ensure compliance, and conducting comprehensive energy and water evaluations.

15

Human-system interface design review guideline: The development of draft revision 1 to NUREG-0700  

SciTech Connect (OSTI)

Advanced human-system interface (HSI) technologies are being developed in the commercial nuclear power industry. These HSIs may have significant implications for plant safety in that they will affect the ways in which the operator interacts with and supervises an increasingly complex system. The U.S. Nuclear Regulatory Commission (NRC) reviews the HSI aspects of nuclear plants to ensure that operator performance and reliability are supported. The NRC is developing guidance to support its review of these advanced designs. The guidance consists of an evaluation methodology and an extensive set of human factors guidelines which are used in one aspect of the evaluation. The paper describes the guidance development of the evaluation methodology and the guidelines.

O`Hara, J.; Stubler, W.; Brown, W. [Brookhaven National Lab., Upton, NY (United States)] [and others

1996-03-01T23:59:59.000Z

16

SITE DESIGN GUIDELINES PEDESTRIAN VEHICULAR BICYCLE VEGETATION FURNISHINGS LIGHTING SIGNAGE PAVING SITEWORK PARKING  

E-Print Network [OSTI]

SITE DESIGN GUIDELINES PEDESTRIAN VEHICULAR BICYCLE VEGETATION FURNISHINGS LIGHTING SIGNAGE PAVING.7 Pedestrians .................................................................................... 3.8 Bicycles ..................................................... Section Four Bicycle Systems 4.1 Shared Roadways

Duchowski, Andrew T.

17

March 23, 2008 DB:EER Model -1 1 Informal Design Guidelines  

E-Print Network [OSTI]

March 23, 2008 DB:EER Model - 1 1 Informal Design Guidelines #12;March 23, 2008 DB:EER Model - 1 2 Design Guidelines for Relational Schema + #12;March 23, 2008 DB:EER Model - 1 3 - Measuring the Quality, 2008 DB:EER Model - 1 4 - Database Design Methodology A Bottom-Up Method We start by identifying all

Adam, Salah

18

The Quasi-Distributed Gap Technique for Planar Inductors-Design Guidelines  

E-Print Network [OSTI]

The Quasi-Distributed Gap Technique for Planar Inductors-Design Guidelines Jiankun Hu C. R The Quasi-Distributed Gap Technique for Planar Inductors: Design Guidelines Jiankun Hu Charles R. Sullivan of low-permeability magnetic material to form a uniformly distributed gap can facilitate the design

19

Overview of NCHRP Design Guideline for EPS-Block Geofoam in Slope Stabilization and Repair  

E-Print Network [OSTI]

1 Overview of NCHRP Design Guideline for EPS-Block Geofoam in Slope Stabilization and Repair David in Construction Applications (EPS 2011 Norway) June 6-8, 2011 #12;2 ABSTRACT This paper presents an overview of the design guideline for the use of expanded polystyrene (EPS)-block geofoam for slope stabilization

Horvath, John S.

20

Passive solar design strategies: Remodeling guidelines for conserving energy at home  

SciTech Connect (OSTI)

The idea of passive solar is simple, but applying it effectively does require information and attention to the details of design and construction. Some passive solar techniques are modest and low-cost, and require only small changes in remodeler's typical practice. At the other end of the spectrum, some passive solar systems can almost eliminate a house's need for purchased heating (and in some cases, cooling) energy -- but probably at a relatively high first cost. In between are a broad range of energy-conserving passive solar techniques. Whether or not they are cost-effective, practical and attractive enough to offer a market advantage to any individual remodeler depends on very specific factors such as local costs, climate, and market characteristics. Passive solar design strategies: Remodeling Guidelines For Conserving Energy At Homes is written to help give remodelers the information they need to make these decisions. Passive Solar Design Strategies is a package in three basic parts: The Guidelines contain information about passive solar techniques and how they work, and provides specific examples of systems which will save various percentages of energy; The Worksheets offer a simple, fill-in-the-blank method to pre-evaluate the performance of a specific design; The Worked Example demonstrates how to complete the worksheets for a typical residence.

Not Available

1991-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Passive solar design strategies: Remodeling guidelines for conserving energy at home. [Final report  

SciTech Connect (OSTI)

The idea of passive solar is simple, but applying it effectively does require information and attention to the details of design and construction. Some passive solar techniques are modest and low-cost, and require only small changes in remodeler`s typical practice. At the other end of the spectrum, some passive solar systems can almost eliminate a house`s need for purchased heating (and in some cases, cooling) energy -- but probably at a relatively high first cost. In between are a broad range of energy-conserving passive solar techniques. Whether or not they are cost-effective, practical and attractive enough to offer a market advantage to any individual remodeler depends on very specific factors such as local costs, climate, and market characteristics. Passive solar design strategies: Remodeling Guidelines For Conserving Energy At Homes is written to help give remodelers the information they need to make these decisions. Passive Solar Design Strategies is a package in three basic parts: The Guidelines contain information about passive solar techniques and how they work, and provides specific examples of systems which will save various percentages of energy; The Worksheets offer a simple, fill-in-the-blank method to pre-evaluate the performance of a specific design; The Worked Example demonstrates how to complete the worksheets for a typical residence.

Not Available

1991-12-31T23:59:59.000Z

22

City of San Jose - Solar Access Design Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

City of San Jose - Solar Access Design Guidelines City of San Jose - Solar Access Design Guidelines City of San Jose - Solar Access Design Guidelines < Back Eligibility Construction Residential Savings Category Heating & Cooling Commercial Heating & Cooling Solar Heating Buying & Making Electricity Water Heating Program Info State California Program Type Solar/Wind Access Policy Provider City of San Jose The San Jose Environmental Services Department has developed voluntary guidelines to encourage solar orientation in new construction. These Solar Access Design Guidelines specify that the long axis of new dwellings should face within 30 degrees west and 45 degrees east of true south. Because houses in a subdivision usually face the street, planners in San Jose found that the easiest way to achieve solar orientation was to orient the streets

23

Guidelines for preparing criticality safety evaluations at Department of Energy non-reactor nuclear facilities  

SciTech Connect (OSTI)

This document contains guidelines that should be followed when preparing Criticality Safety Evaluations that will be used to demonstrate the safety of operations performed at DOE non-reactor nuclear facilities. Adherence to these guidelines will provide consistency and uniformity in criticality safety evaluations (CSEs) across the complex and will document compliance with the requirements of DOE Order 5480.24.

Not Available

1993-11-01T23:59:59.000Z

24

DESIGN FOR ENERGY EFFICIENCY: PROPOSITION OF A GUIDELINES-BASED TOOL  

E-Print Network [OSTI]

1 DESIGN FOR ENERGY EFFICIENCY: PROPOSITION OF A GUIDELINES-BASED TOOL J. Bonvoisin, F. Mathieux, L. Domingo, and D. Brissaud Keywords: ecodesign, energy efficiency, guideline, energy using products (Eu. In spite of all the improvements made to the energy efficiency of several appliances, the savings

Paris-Sud XI, Université de

25

Metal wastage design guidelines for bubbling fluidized-bed combustors. Final report  

SciTech Connect (OSTI)

These metal wastage design guidelines identify relationships between metal wastage and (1) design parameters (such as tube size, tube spacing and pitch, tube bundle and fluidized-bed height to distributor, and heat exchanger tube material properties) and (2) operating parameters (such as fluidizing velocity, particle size, particle hardness, and angularity). The guidelines are of both a quantitative and qualitative nature. Simplified mechanistic models are described, which account for the essential hydrodynamics and metal wastage processes occurring in bubbling fluidized beds. The empirical correlational approach complements the use of these models in the development of these design guidelines. Data used for model and guideline validation are summarized and referenced. Sample calculations and recommended design procedures are included. The influences of dependent variables on metal wastage, such as solids velocity, bubble size, and in-bed pressure fluctuations, are discussed.

Lyczkowski, R.W.; Podolski, W.F.; Bouillard, J.X.; Folga, S.M. [Argonne National Lab., IL (United States)

1992-11-01T23:59:59.000Z

26

Guidelines for preparing criticality safety evaluations at Department of Energy non-reactor nuclear facilities  

SciTech Connect (OSTI)

This Department of Energy (DOE) is approved for use by all components of DOE. It contains guidelines that should be followed when preparing Criticality Safety Evaluations that will be used to demonstrate the safety of operations performed at DOE Non-Reactor Nuclear Facilities. Adherence with these guidelines will provide consistency and uniformity in Criticality Safety Evaluations (CSEs) across the complex and will document compliance with DOE Order 5480.24 requirements as they pertain to CSEs.

NONE

1998-09-01T23:59:59.000Z

27

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities  

Broader source: Energy.gov (indexed) [DOE]

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities (42 U.S.C. 8253 Subsection (f), Use of Energy and Water Efficiency Measures in Federal Buildings) 25 November 2008 I. Background A. Authority Section 432 of the Energy Independence and Security Act of 2007 (EISA) amends section 543 of the National Energy Conservation Policy Act, by adding a new subsection (f) Use of Energy and Water Efficiency Measures in Federal Buildings (42 U.S.C. 8253(f); referred to as "the statute" in this guidance). The new subsection prescribes a framework for facility energy project management and benchmarking, including the following elements: * Designated "facility energy managers" for ensuring compliance of "covered facilities"

28

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities (42 U.S.C. 8253 Subsection (f), Use of Energy and Water Efficiency Measures in Federal Buildings) 25 November 2008 I. Background A. Authority Section 432 of the Energy Independence and Security Act of 2007 (EISA) amends section 543 of the National Energy Conservation Policy Act, by adding a new subsection (f) Use of Energy and Water Efficiency Measures in Federal Buildings (42 U.S.C. 8253(f); referred to as "the statute" in this guidance). The new subsection prescribes a framework for facility energy project management and benchmarking, including the following elements: * Designated "facility energy managers" for ensuring compliance of "covered facilities"

29

Guidelines for sustainable building design: Recommendations from the Presidio of San Francisco energy efficiency design charrette  

SciTech Connect (OSTI)

In 1994, the Bay Chapter of the Association of Energy Engineers{reg_sign} organized a two-day design charrette for energy-efficient redevelopment of buildings by the National Park Services (NPS) at the Presidio of San Francisco. This event brought together engineers, researchers, architects, government officials, and students in a participatory environment to apply their experience to create guidelines for the sustainable redesign of Presidio buildings. The venue for the charrette was a representative barracks building located at the Main Post of the Presidio. Examination of this building allowed for the development of design recommendations, both for the building and for the remainder of the facilities. The charrette was organized into a committee structure consisting of: steering, measurement and monitoring, modeling, building envelope and historic preservation (architectural), HVAC and controls, lighting, and presentation. Prior to the charrette itself, the modeling and measurement/monitoring committees developed substantial baseline data for the other committees during the charrette. An integrated design approach was initiated through interaction between the committees during the charrette. Later, committee reports were cross-referenced to emphasize whole building design and systems integration.

Brown, K.; Sartor, D.; Greenberg, S. [and others

1996-05-01T23:59:59.000Z

30

Advanced Strategy Guideline: Air Distribution Basics and Duct Design  

SciTech Connect (OSTI)

This report discusses considerations for designing an air distribution system for an energy efficient house that requires less air volume to condition the space. Considering the HVAC system early in the design process will allow adequate space for equipment and ductwork and can result in cost savings. Principles discussed that will maximize occupant comfort include delivery of the proper amount of conditioned air for appropriate temperature mixing and uniformity without drafts, minimization of system noise, the impacts of pressure loss, efficient return air duct design, and supply air outlet placement, as well as duct layout, materials, and sizing.

Burdick, A.

2011-12-01T23:59:59.000Z

31

Design guidelines for SAR digital receiver/exciter boards.  

SciTech Connect (OSTI)

High resolution radar systems generally require combining fast analog to digital converters and digital to analog converters with very high performance digital signal processing logic. These mixed analog and digital printed circuit boards present special challenges with respect to electromagnetic interference. This document first describes the mechanisms of interference on such boards then follows up with a discussion of prevention techniques and finally provides a checklist for designers to help avoid common mistakes.

Dudley, Peter A.

2009-08-01T23:59:59.000Z

32

DARTMOUTH COLLEGE DESIGN FEBRUARY 15, 2012 & CONSTRUCTION GUIDELINES  

E-Print Network [OSTI]

(BICSI) Standards. National Electrical Manufacturers Assoc. (NEMA) Standards. Electronics Industry Assoc.Design Criteria 3.1 Distribution Frames (MDF/BDF/IDF) 3.2. Cabling 3.2.1. Inter and Intra-Building 3.2.2 Intra-Building 3.2.3 Inter-Building 3.2.4 Horizontal Cable 3.2.5 Pathway Specifications 3.3 Work Station

Myers, Lawrence C.

33

Design guidelines for carbon-dioxide scrubbers. Revision A. Technical manual  

SciTech Connect (OSTI)

Design data and guidelines are presented to help predict the performance of axial flow carbon dioxide canister designs using alkali metal hydroxide absorbers. The design data are derived from a large series of laboratory tests conducted at the Naval Coastal Systems Center to isolate the effects of environmental and goemetric parameters on canister absorption efficiency. Sample canister designs are considered to demonstrate the use of the derived data to predict effective canister life and pressure drop levels. Alternative techniques for the sorption of carbon dioxide are also reviewed.

Nuckols, M.L.; Purer, A.; Deason, G.A.

1985-07-01T23:59:59.000Z

34

23 SDSU Curriculum Guide 2010 Undergraduate Curriculum Committee Guidelines for Evaluating New Course  

E-Print Network [OSTI]

23 SDSU Curriculum Guide 2010 Undergraduate Curriculum Committee Guidelines for Evaluating New course propos- als: Course Prerequisites and Description 1. Does the course title accurately to the proposed course? What purpose do they serve? 5. Does it duplicate any existing course(s) presently

Ponce, V. Miguel

35

Energy Design Guidelines for High Performance Schools: Cold and Humid Climates  

SciTech Connect (OSTI)

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

36

Energy Design Guidelines for High Performance Schools: Temperate and Mixed Climates  

SciTech Connect (OSTI)

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

37

Energy Design Guidelines for High Performance Schools: Hot and Dry Climates (CD-ROM)  

SciTech Connect (OSTI)

School districts around the country are finding that smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs. The design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-03-01T23:59:59.000Z

38

Energy Design Guidelines for High Performance Schools: Hot and Dry Climates  

SciTech Connect (OSTI)

School districts around the country are finding that smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create an exemplary building that is both energy and resource efficient.

Not Available

2002-01-01T23:59:59.000Z

39

Energy Design Guidelines for High Performance Schools: Cool and Humid Climates  

SciTech Connect (OSTI)

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

40

Energy Design Guidelines for High Performance Schools: Temperate and Humid Climates  

SciTech Connect (OSTI)

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Energy Design Guidelines for High Performance Schools: Cool and Dry Climates  

SciTech Connect (OSTI)

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

42

Energy Design Guidelines for High Performance Schools: Hot and Humid Climates  

SciTech Connect (OSTI)

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

43

Energy Design Guidelines for High Performance Schools: Hot and Dry Climates (Revision)  

SciTech Connect (OSTI)

School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

Not Available

2002-06-01T23:59:59.000Z

44

Simulation as a Tool to Develop Guidelines of Envelope Design of a Typical Office Building in Egypt  

E-Print Network [OSTI]

This paper describes the use of building performance simulation software in order to develop guidelines for designing energy-efficient office building. In Egypt energy codes for all building types are being under development. On the other hand...

Samaan, M.M.; Ahmed, A.N.; Farag, O.M.A.; El-Sayed Khalil, M.

2011-01-01T23:59:59.000Z

45

Evaluating Design Project Creativity in Engineering Design Courses Postdoctoral Fellow  

E-Print Network [OSTI]

Evaluating Design Project Creativity in Engineering Design Courses I. Chiu Postdoctoral Fellow. A goal of engineering design courses is to teach creativity, or at least creativity methods, e an engineering design course, such as for a design project. In this paper, we discuss creativity and approaches

Salustri, Filippo A.

46

The Sustainable Design Guidelines are the product of the ASU Office of the University Architect with the support and participation of the Sustainable Design Advisory Committee.  

E-Print Network [OSTI]

) is committed to leadership in sustainability education, research, operations, and outreach. With a growingThe Sustainable Design Guidelines are the product of the ASU Office of the University Architect with the support and participation of the Sustainable Design Advisory Committee. ASU Sustainable Design

Zhang, Junshan

47

Arellano, Tatum, Stark, Horvath, Leshchinsky 1 Interim Design Guideline for EPS-Block Geofoam in Slope Stabilization and Repair  

E-Print Network [OSTI]

Arellano, Tatum, Stark, Horvath, Leshchinsky 1 Interim Design Guideline for EPS-Block Geofoam of expanded polystyrene (EPS)-block geofoam3 for slope stabilization and repair based on the National for the use of EPS-block geofoam6 for the function of lightweight fill in slope stability applications

48

HVAC Energy Recovery Design and Economic Evaluation  

E-Print Network [OSTI]

ENRECO has prepared this paper on HVAC energy recovery to provide the engineer with an overview of the design engineering as well as the economic analysis considerations necessary to evaluate the potential benefits of energy recovery....

Kinnier, R. J.

1979-01-01T23:59:59.000Z

49

Physical protection system design and evaluation  

SciTech Connect (OSTI)

The design of an effective physical protection system includes the determination of physical protection system objectives, initial design of a physical protection system, design evaluation, and probably a redesign or refinement. To develop the objectives, the designer must begin by gathering information about facility operation and conditions, such as a comprehensive description of the facility, operating conditions, and the physical protection requirements. The designer then needs to define the threat. This involves considering factors about potential adversaries: class of adversary, adversary`s capabilities, and range of adversary`s tactics. Next, the designer should identify targets. Determination of whether or not the materials being protected are attractive targets is based mainly on the ease or difficulty of acquisition and desirability of the material. The designer now knows the objectives of the physical protection system, that is, {open_quotes}what to protect against whom.{close_quotes} The next step is to design the system by determining how best to combine such elements as fences, vaults, sensors and assessment devices, entry control elements, procedures, communication devices, and protective forces personnel to meet the objectives of the system. Once a physical protection system is designed, it must be analyzed and evaluated to ensure it meets the physical protection objectives. Evaluation must allow for features working together to ensure protection rather than regarding each feature separately. Due to the complexity of the protection systems, an evaluation usually requires modeling techniques. If any vulnerabilities are found, the initial system must be redesigned to correct the vulnerabilities and a reevaluation conducted. This paper reviews the physical protection system design and methodology mentioned above. Examples of the steps required and a brief introduction to some of the technologies used in modem physical protections system are given.

Williams, J.D.

1997-03-01T23:59:59.000Z

50

Guidelines for the Monitoring, Evaluation, Reporting, Verification, and Certification of Forestry Projects for Climate Change Mitigation  

E-Print Network [OSTI]

MERVC guidelines for climate change projects require non-applicable in the climate change project, these items needof Forestry Projects for Climate Change Mitigation Edward

Vine, Edward; Sathaye, Jayant; Makundi, Willy

1999-01-01T23:59:59.000Z

51

Evaluation of high strength concrete prestressed bridge girder design  

E-Print Network [OSTI]

3.4.2 Live Load Model ..........................................................................35 3.4.3 Live Load Distribution Factor ......................................................37 3....4.4 Design Live Load Moments..........................................................38 3.4.5 Limit States ...................................................................................40 3.5 TxDOT DESIGN GUIDELINES...

Cuadros Olave, Gladys

2004-09-30T23:59:59.000Z

52

Changes in the acoustical requirements of the 2014 editions of the Facility Guidelines Institute's Guidelines for Designand Construction of Hospitals and Outpatient Facilities and its reference document Sound & Vibration Design Guidelinesfor Health Care Facilities  

Science Journals Connector (OSTI)

Acoustical design criteria for health care facilities as defined by the FGI Guidelines have been updated in the recently published 2014 edition. Sound & Vibration Design Guidelines for Health Care Facilities (S&V3.0) serves as the sole acoustical reference for the FGI Guidelines and has also been updated as part of the 2014 FGI cycle. The S&V reference is authored and edited by the FGI's acoustical working group. The secretary of this group (Horan) will summarize these changes and will also discuss the public review and comment process that led to the updated Guidelines. This same process will be used in the forthcoming cycle in preparation for the 2018 edition(s).

2014-01-01T23:59:59.000Z

53

Design and Evaluation of Novel High Capacity Cathode Materials...  

Broader source: Energy.gov (indexed) [DOE]

Design and Evaluation of Novel High Capacity Cathode Materials Design and Evaluation of Novel High Capacity Cathode Materials 2009 DOE Hydrogen Program and Vehicle Technologies...

54

Design and Evaluation of Novel High Capacity Cathode Materials...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

High Capacity Cathodes Vehicle Technologies Office Merit Review 2014: Design and Evaluation of High Capacity Cathodes Design and Evaluation of Novel High Capacity Cathode Materials...

55

International Energy Agency design tool evaluation procedure  

SciTech Connect (OSTI)

Detailed state-of-the-art building energy simulation models from nations participating in International Energy Agency (IEA) Task VIII are used to develop a quantitative procedure to evaluate more simplified design tools. Simulations are performed with the detailed models on a series of cases that progress systematically from the extremely simple to the relatively realistic. Output values for the cases, such as annual loads, annual maximum and minimum temperatures, and peak loads, are used to set target ranges with which the results from more simplified design tools can be compared. The more realistic cases, although geometrically simple, test the ability of the design tools to model such combined effects as thermal mass, direct gain windows, overhangs, internally generated heat, and dead-band and set-back thermostat control strategies. 5 refs., 9 figs., 4 tabs.

Judkoff, R.; Barakat, S.; Bloomfield, D.; Poel, B.; Stricker, R.; van Haaster, P.; Wortman, D.

1988-07-01T23:59:59.000Z

56

Design and Evaluation of Novel High Capacity Cathode Materials...  

Broader source: Energy.gov (indexed) [DOE]

and Evaluation of Novel High Capacity Cathode Materials Design and Evaluation of Novel High Capacity Cathode Materials 2011 DOE Hydrogen and Fuel Cells Program, and Vehicle...

57

Design for manufacturability: quantitative measures for design evaluation  

E-Print Network [OSTI]

In a design for manufacturing (DFM) approach, the designer has to consider the interactions between the various parameters in the design and the ease with which it can be manufactured, very early in the design process. This research is aimed...

Polisetty, Francis Showry Kumar

2012-06-07T23:59:59.000Z

58

Duct injection for SO{sub 2} control, Design Handbook, Volume 1, Process design and engineering guidelines  

SciTech Connect (OSTI)

PETC developed a comprehensive program of coal-related, acid-rain research and development with a major activity area centering on flue gas cleanup and control of SO{sub 2} emissions. Particular emphasis was placed on the retrofit measures for older coal-fired power plants which predate the 1971 New Source Performance Standards. Candidate emission control technologies fall into three categories, depending upon their point of application along the fuel path (i.e., pre, during, or post combustion). The post-combustion, in-duct injection of a calcium-based chemical reagent seemed promising. Preliminary studies showed that reagent injection between the existing air heater and electrostatic precipitator (ESP) could remove between 50-60% of the SO{sub 2} and produce an environmentally safe, dry, solid waste that is easily disposed. Although SO{sub 2} removal efficiencies were less, the estimated capital costs for duct injection technology were low making the economics of duct injection systems seem favorable when compared to conventional wet slurry scrubbers under certain circumstances. With the promulgation of the Clean Air Act Amendments of 1990 came more incentive for the development of low capital cost flue gas desulfurization (FGD) processes. A number of technical problems had to be resolved, however, before duct injection technology could be brought to a state of commercial readiness. The Duct Injection Technology Development Program was launched as a comprehensive, four-year research effort undertaken by PETC to develop this new technology. Completed in 1992, this Duct Injection Design Handbook and the three-dimensional predictive mathematical model constitute two primary end products from this development program. The aim of this design handbook and the accompanying math model is to provide utility personnel with sufficient information to evaluate duct injection technology against competing SO{sub 2} emissions reduction strategies for an existing plant.

NONE

1995-09-01T23:59:59.000Z

59

ANL/APS/TB-44, Guidelines for Beamline and Front-End Radiation Shielding Design at the Advanced Photon Source  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

APS/TB-44 Rev. 4 APS/TB-44 Rev. 4 Guidelines for Beamline and Front-End Radiation Shielding Design at the Advanced Photon Source Revision 4 Advanced Photon Source About Argonne National Laboratory Argonne is a U.S. Department of Energy laboratory managed by UChicago Argonne, LLC under contract DE-AC02-06CH11357. The Laboratory's main facility is outside Chicago, at 9700 South Cass Avenue, Argonne, Illinois 60439. For information about Argonne and its pioneering science and technology programs, see www.anl.gov. Availability of This Report This report is available, at no cost, at http://www.osti.gov/bridge. It is also available on paper to the U.S. Department of Energy and its contractors, for a processing fee, from: U.S. Department of Energy Office of Scientific and Technical Information

60

Reassessing Residential Design in Hawaii: Design Construction Building Analysis and Publishing Design Guidelines for a Passive-Design Model Home on Hawaiian Homeland  

E-Print Network [OSTI]

, cost effective housing design for a climate where heat and humidity can challenge the success of a passively designed home. The project partners combined their resources and expertise to ensure that the project had a tangible outcome... designed into the model house and absent from the control house, are generally passive technologies, relatively inexpensive and have shown, through this study, to be quite effective. Neither the model nor the control house has any insulation...

Meder, S.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Design and Evaluation of High Capacity Cathodes  

Broader source: Energy.gov (indexed) [DOE]

to prepare advanced electrodes and surfaces with stable architectural designs Use atomic-scale modeling as a guide to identify, design and understand the structural...

62

Acoustical and Noise Control Criteria and Guidelines for Building Design and Operations  

E-Print Network [OSTI]

Noise, vibration and acoustical design, construction, commissioning and operation practices influence building cost, efficiency, performance and effectiveness. Parameters for structural vibration, building systems noise, acoustics and environmental...

Evans, J. B.; Himmel, C. N.

63

Towards videogame design guidelines to promote significant leisure activities in Mexican older adults  

Science Journals Connector (OSTI)

The purpose of this study is to formulate design guides to create digital games that promote significant leisure activities in older adults from Mexico. As a first step towards this goal, seven-hundred and ninety-four older adults up to 60 years old ... Keywords: game design, leisure activities, older adults

Ramón R. Palacio; Christian O. Acosta; Alberto L. Morán; Joaquín Cortez

2012-10-01T23:59:59.000Z

64

Proposed risk evaluation guidelines for use by the DOE-AL Nuclear Explosive Safety Division in evaluating proposed shipments of nuclear components  

SciTech Connect (OSTI)

The licensing requirements of 10 CFR 71 (US Code of Federal Regulations) are the primary criteria used to license proposed US Department of Energy (DOE) shipments of nuclear components. However, if a shipment cannot meet 10 CFR 71 requirements, a Transportation System Risk Assessment (TSRA) is prepared to document: (1) the degree of compliance of proposed DOE shipments of nuclear components with applicable federal regulations, and (2) the risk associated with the proposed shipments. The Nuclear Explosive Safety Division (NESD) of the Department of Energy, Albuquerque Area Office (DOE-AL) is responsible for evaluating TSRAs and for preparing Safety Evaluation Reports (SERs) to authorize the off-site transport. Hazards associated with the transport may include the presence of fissile material, chemically and radiologically toxic uranium, and ionizing radiation. The Nuclear Regulatory Commission (NRC) has historically considered only radiological hazards in licensing the transport of radiological material because the US Department of Transportation considers licensing requirements of nonradiological (i.e., chemically toxic) hazards. The requirements of 10 CFR 71 are based primarily on consideration of radiological hazards. For completeness, this report provides information for assessing the effects of chemical toxicity. Evaluating the degree of compliance with the requirements of 10 CFR 71 is relatively straightforward. However, there are few precedents associated with developing TSRA risk assessments for packages that do not comply with all of the requirements of 10 CFR 71. The objective of the task is to develop Risk Evaluation Guidelines for DOE-AL to use when evaluating a TSRA. If the TSRA shows that the Risk Evaluation Guidelines are not exceeded, then from a risk perspective the TSRA should be approved if there is evidence that the ALARA (as low as reasonably achievable) principle has been applied.

Just, R.A.; Love, A.F.

1997-10-01T23:59:59.000Z

65

Low-Energy Building Design Guidelines: Energy-Efficient Design for New Federal Facilities. Federal Energy Management Program (FEMP) Booklet  

Broader source: Energy.gov (indexed) [DOE]

Introduction Introduction Incorporating energy efficiency, renewable energy, and sustainable green design features into all Federal buildings has become a top priority in recent years for facilities managers, designers, contracting officers, and others in government buildings procurement. These progressive design strategies have been formalized through Executive Order 13123 (known as Greening the Government through Efficient Energy Management), which was issued on June 3, 1999. There are significant oppor- tunities to accomplish the goals set forth in the executive order, whether in new building design or in the context of renovations. This guidebook addresses the first category-the design process for new Federal facilities. Because energy-efficient buildings reduce both resource depletion and the

66

Residential building design : comprehensive comparative guidelines for building single-family dwellings in Hawaii  

E-Print Network [OSTI]

Energy shortages, earthquakes, and hurricanes are environmental factors that challenge the home designers of Hawaii. The depletion of renewable natural resources and global warming trends foreshadow energy shortage and the ...

Nagata, Rochelle Morie

1997-01-01T23:59:59.000Z

67

Design and Evaluation of Novel High Capacity Cathode Materials  

Broader source: Energy.gov (indexed) [DOE]

Design and Evaluation of Novel High Capacity Cathode Materials Christopher Johnson and Michael Thackeray Chemical Sciences and Engineering Division, Argonne Annual Merit Review DOE...

68

Design and Evaluation of High Capacity Cathodes  

Broader source: Energy.gov [DOE]

2013 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

69

Moving towards inclusive design guidelines for socially and ethically aware HCI  

Science Journals Connector (OSTI)

......Standard on managing Inclusive Design (BS 7000-6); CEN/CENELEC Guide 6 3...living in the same house, has evolved to a nuclear family including only parents and children...expensiveWhen possible, select the lower cost choice Invasive and/or socially unacceptable......

Julio Abascal; Colette Nicolle

2005-09-01T23:59:59.000Z

70

Postoperative Radiotherapy for Prostate Cancer: A Comparison of Four Consensus Guidelines and Dosimetric Evaluation of 3D-CRT Versus Tomotherapy IMRT  

SciTech Connect (OSTI)

Purpose: Despite the benefits of adjuvant radiotherapy after radical prostatectomy, approximately one-half of patients relapse. Four consensus guidelines have been published (European Organization for Research and Treatment of Cancer, Faculty of Radiation Oncology Genito-Urinary Group, Princess Margaret Hospital, Radiation Therapy Oncology Group) with the aim of standardizing the clinical target volume (CTV) delineation and improve outcomes. To date, no attempt has been made to compare these guidelines in terms of treatment volumes or organ at risk (OAR) irradiation. The extent to which the guideline-derived plans meet the dosimetric constraints of present trials or of the Quantitative Analysis of Normal Tissue Effects in the Clinic (QUANTEC) trial is also unknown. Our study also explored the dosimetric benefits of intensity-modulated radiotherapy (IMRT). Methods and Materials: A total of 20 patients treated with postoperative RT were included. The three-dimensional conformal radiotherapy (3D-CRT) plans were applied to cover the guideline-generated planning target volumes (66 Gy in 33 fractions). Dose-volume histograms (DVHs) were analyzed for CTV/planning target volume coverage and to evaluate OAR irradiation. The OAR DVHs were compared with the constraints proposed in the QUANTEC and Radiotherapy and Androgen Deprivation In Combination After Local Surgery (RADICALS) trials. 3D-CRT plans were compared with the tomotherapy plans for the Radiation Therapy Oncology Group planning target volume to evaluate the advantages of IMRT. Results: The CTV differed significantly between guidelines (p < 0.001). The European Organization for Research and Treatment of Cancer-CTVs were significantly smaller than the other CTVs (p < 0.001). Differences in prostate bed coverage superiorly accounted for the major volumetric differences between the guidelines. Using 3D-CRT, the DVHs rarely met the QUANTEC or RADICALS rectal constraints, independent of the guideline used. The RADICALS bladder constraints were met most often by the European Organization for Research and Treatment of Cancer consensus guideline (14 of 20). The tomotherapy IMRT plans resulted in significant OAR sparing compared with the 3D-CRT plans; however, the RADICALS and QUANTEC criteria were still missed in a large percentage of cases. Conclusion: Treatment volumes using the current consensus guidelines differ significantly. For the four CTV guidelines, the rectal and bladder DVH constraints proposed in the QUANTEC and RADICALS trials are rarely met with 3D-CRT. IMRT results in significant OAR sparing; however, the RADICALS dose constraints are still missed for a large percentage of cases. The rectal and bladder constraints of RADICALS should be modified to avoid a reduction in the CTVs.

Malone, Shawn, E-mail: smalone@ottawahospital.on.ca [Division of Radiation Oncology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada)] [Division of Radiation Oncology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada); Croke, Jennifer [Division of Radiation Oncology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada)] [Division of Radiation Oncology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada); Roustan-Delatour, Nicolas; Belanger, Eric [Department of Pathology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada)] [Department of Pathology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada); Avruch, Leonard [Department of Radiology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada)] [Department of Radiology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada); Malone, Colin [Division of Radiation Oncology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada)] [Division of Radiation Oncology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada); Morash, Christopher [Division of Urology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada)] [Division of Urology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada); Kayser, Cathleen; Underhill, Kathryn; Li Yan; Malone, Kyle [Division of Radiation Oncology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada)] [Division of Radiation Oncology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada); Nyiri, Balazs [Department of Medical Physics, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada)] [Department of Medical Physics, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada); Spaans, Johanna [Division of Radiation Oncology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada)] [Division of Radiation Oncology, Ottawa Hospital, University of Ottawa, Ottawa, Ontario (Canada)

2012-11-01T23:59:59.000Z

71

Pesticide exposure and sprayer design: ergonomics evaluation to reduce pesticide  

E-Print Network [OSTI]

Pesticide exposure and sprayer design: ergonomics evaluation to reduce pesticide exposure Sonia of operator exposure to plant protection products through the introduction of ergonomics to the design process. It is suggested that a systematic ergonomics evaluation of sprayer interfaces with the view of reducing direct

72

Cost analysis guidelines  

SciTech Connect (OSTI)

The first phase of the Depleted Uranium Hexafluoride Management Program (Program)--management strategy selection--consists of several program elements: Technology Assessment, Engineering Analysis, Cost Analysis, and preparation of an Environmental Impact Statement (EIS). Cost Analysis will estimate the life-cycle costs associated with each of the long-term management strategy alternatives for depleted uranium hexafluoride (UF6). The scope of Cost Analysis will include all major expenditures, from the planning and design stages through decontamination and decommissioning. The costs will be estimated at a scoping or preconceptual design level and are intended to assist decision makers in comparing alternatives for further consideration. They will not be absolute costs or bid-document costs. The purpose of the Cost Analysis Guidelines is to establish a consistent approach to analyzing of cost alternatives for managing Department of Energy`s (DOE`s) stocks of depleted uranium hexafluoride (DUF6). The component modules that make up the DUF6 management program differ substantially in operational maintenance, process-options, requirements for R and D, equipment, facilities, regulatory compliance, (O and M), and operations risk. To facilitate a consistent and equitable comparison of costs, the guidelines offer common definitions, assumptions or basis, and limitations integrated with a standard approach to the analysis. Further, the goal is to evaluate total net life-cycle costs and display them in a way that gives DOE the capability to evaluate a variety of overall DUF6 management strategies, including commercial potential. The cost estimates reflect the preconceptual level of the designs. They will be appropriate for distinguishing among management strategies.

Strait, R.S.

1996-01-10T23:59:59.000Z

73

Early Site Permit Demonstration Program: Guidelines for determining design basis ground motions. Volume 2, Appendices  

SciTech Connect (OSTI)

This report develops and applies a methodology for estimating strong earthquake ground motion. The motivation was to develop a much needed tool for use in developing the seismic requirements for structural designs. An earthquake`s ground motion is a function of the earthquake`s magnitude, and the physical properties of the earth through which the seismic waves travel from the earthquake fault to the site of interest. The emphasis of this study is on ground motion estimation in Eastern North America (east of the Rocky Mountains), with particular emphasis on the Eastern United States and southeastern Canada. Eastern North America is a stable continental region, having sparse earthquake activity with rare occurrences of large earthquakes. While large earthquakes are of interest for assessing seismic hazard, little data exists from the region to empirically quantify their effects. The focus of the report is on the attributes of ground motion in Eastern North America that are of interest for the design of facilities such as nuclear power plants. This document, Volume II, contains Appendices 2, 3, 5, 6, and 7 covering the following topics: Eastern North American Empirical Ground Motion Data; Examination of Variance of Seismographic Network Data; Soil Amplification and Vertical-to-Horizontal Ratios from Analysis of Strong Motion Data From Active Tectonic Regions; Revision and Calibration of Ou and Herrmann Method; Generalized Ray Procedure for Modeling Ground Motion Attenuation; Crustal Models for Velocity Regionalization; Depth Distribution Models; Development of Generic Site Effects Model; Validation and Comparison of One-Dimensional Site Response Methodologies; Plots of Amplification Factors; Assessment of Coupling Between Vertical & Horizontal Motions in Nonlinear Site Response Analysis; and Modeling of Dynamic Soil Properties.

Not Available

1993-03-18T23:59:59.000Z

74

A quantitative and objective evaluation approach for optimal selection of design concept in conceptual design stage  

E-Print Network [OSTI]

quantities: Projected Assembly Time and Projected Assembly Cost. Overall, the approach presented is a small step, but it aids in quantifying vague design information as numbers early in the design cycle and makes the concept evaluation and selection process...

Tiwari, Sanjay

2012-06-07T23:59:59.000Z

75

October 24, 2003, Assessment Criteria and Guidelines for Determining the Adequacy of Software Used in the Safety Analysis and Design of Defense Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

4.1 4.1 Revision 3 October 24, 2003 U. S. Department of Energy Assessment Criteria and Guidelines for Determining the Adequacy of Software Used in the Safety Analysis and Design of Defense Nuclear Facilities October 24, 2003 CRAD - 4.2.4.1 Revision 3 October 24, 2003 ii TABLE OF CONTENTS ACRONYMS ..................................................................................................................................iii GLOSSARY ...................................................................................................................................iv 1.0 INTRODUCTION ...............................................................................................................1 2.0 BACKGROUND .................................................................................................................2

76

Development, evaluation, and design applications of an AMTEC converter model  

E-Print Network [OSTI]

An AMTEC converter model was developed and its effectiveness as a design tool was evaluated. To develop the model, requirements of the model were defined, modeling equations were selected, and a methodology for model development was established...

Spence, Cliff Alan

2012-06-07T23:59:59.000Z

77

Design and Evaluation of Novel High Capacity Cathode Materials...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

17johnson2011p.pdf More Documents & Publications Design and Evaluation of Novel High Capacity Cathode Materials Lithium Source For High Performance Li-ion Cells Lithium Source...

78

Design and Evaluation of an FPGA Architecture for Software Protection  

E-Print Network [OSTI]

attacks on software systems have become a rapidly growing burden. The growing area of software protection protection using hardware/software codesign techniques. In Proc. of Design, Automation, and Test in EuropeDesign and Evaluation of an FPGA Architecture for Software Protection Joseph Zambreno Department

Zambreno, Joseph A.

79

Design and Evaluation of a Feedback Control EDF Scheduling Algorithm *  

E-Print Network [OSTI]

Design and Evaluation of a Feedback Control EDF Scheduling Algorithm * * Supported in part by NSF. In this paper, we present a feedback control real­time scheduling algorithm and its evaluation. Performance}@cs.virginia.edu, + gt9s@virginia.edu Abstract Despite the significant body of results in real­time scheduling, many real

Son, Sang H.

80

Design for, and Evaluation of Life Cycle Performance  

E-Print Network [OSTI]

?. DESIGN FOR, AND EVALUATION OF LIFE CYCLE PERFORMANCE David J. Ahner Eldon W. Hall GENERAL ELECTRIC COMPANY SCHENECTADY, NEW YORK ABSTRACT EQUIPMENT DEGRADATION Project evaluation necessarily requires performance estimates over..., operating procedures, equipment availabilities, etc. This paper discusses the general nature, and the ther mal interaction of power plant components as individual equipment degradation occurs, describing overall plant performance trends and quant...

Ahner, D. J.; Hall, E. W.

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Design and testing of a procedure for evaluating fuel-efficient crankcase lubricants  

SciTech Connect (OSTI)

Experiments were conducted to design and evaluate a procedure for evaluating the fuel efficiency characteristics of crankcase lubricants using the driving cycles of the 1975 Federal Test Procedure and the Highway Fuel Economy Test. Most of the test protocol was based on guidelines proposed by the American Society for Testing and Materials. Three crankcase lubricants and five oil supplements, as well as a baseline lubricant, were used in eight 1980 model-year vehicles of identical make. The vehicles were operated at 75/sup 0/F (24/sup 0/C) in closely controlled chassis dynamometer tests designed to detect small changes in fuel efficiency. Results from these tests showed measurable increases in fuel economy of 0 to 6% with the test lubricants when compared to a common SAE 30 grade oil. These results are not definitive because of lack of quantification of mileage accumulation effects. The test protocol did reduce measurement variability greatly; this procedure can be applied to evaluation of fuel-efficient oils using larger test fleets. A good potential exists for improving the fuel economy of the US automotive fleet. Because of the large quantities of petroleum consumed in the automotive sector, this potential savings translates into conserving a very significant quantity of petroleum.

Naman, T.M.

1981-04-01T23:59:59.000Z

82

Facility Energy Management Guidelines and Criteria for Energy...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Facility Energy Management Guidelines and Criteria for Energy and Water Evaluations in Covered Facilities Facility Energy Management Guidelines and Criteria for Energy and Water...

83

Knowledge evaluation in product lifecycle design and support  

Science Journals Connector (OSTI)

Abstract Enterprises are focusing more and more on knowledge issues for global product development. This paper describes knowledge evolution processes in product development activities and proposes a knowledge evaluation method in product lifecycle design. The paper also theoretically analyzes the evaluation model and illustrates how knowledge values can be assessed by case study. The case study shows how knowledge values calculated by the model can provide suggestions about which knowledge to choose and what to do next. The knowledge evaluation model serves as a useful tool for managing knowledge in product lifecycle design and support.

Yang Xu; Alain Bernard; Nicolas Perry; Jing Xu; Shigeo Sugimoto

2014-01-01T23:59:59.000Z

84

Biotechnology guidelines  

Science Journals Connector (OSTI)

... SIR-The article by Tim Beardsley on the biotechnology guidelines (Nature 322, 398; 1986) inaccurately implies that the Association of ... guidelines (Nature 322, 398; 1986) inaccurately implies that the Association of Biotechnology Companies (ABC) wants the exemption of well-defined non-coding regulatory sequences removed from ...

BRUCE F. MACKLER

1986-09-11T23:59:59.000Z

85

Inverter Procedures Guideline i DRAFT Guideline for the use of the  

E-Print Network [OSTI]

Inverter Procedures Guideline i DRAFT Guideline for the use of the Performance Test Protocol for Evaluating Inverters Used in GridConnected Photovoltaic Systems Prepared by Bill Brooks KEMAXenergy.whitaker@bewengineering.com #12;Inverter Procedures Guideline 1 DRAFT Guideline for the use of the Performance Test

86

Beyond the Guidelines: Practical lessons for monitoring  

Science Journals Connector (OSTI)

A series of workshops have provided extensive feedback on a recently published manual, Monitoring Guidelines to Evaluate Effects of Forestry Activities on Streams in the Pacific Northwest and Alaska (Guidelines) ...

Lee H. Macdonald; Alan Smart

1993-07-01T23:59:59.000Z

87

Evaluation of Generic EBS Design Concepts and Process Models Implications  

Broader source: Energy.gov (indexed) [DOE]

Generic EBS Design Concepts and Process Models Generic EBS Design Concepts and Process Models Implications to EBS Design Optimization Evaluation of Generic EBS Design Concepts and Process Models Implications to EBS Design Optimization The assessment of generic Engineered Barrier System (EBS) concepts and design optimization to harbor various disposal configurations and waste types needs advanced approaches and methods to analyze barrier performance. The report addresses: 1) Overview of the importance of Thermal-Hydrological-Mechanical-Chemical (THMC) processes to barrier performance, and international collaborations; 2) THMC processes in clay barriers; 3) experimental studies of clay stability and clay-metal interactions at high temperatures and pressures; 4) thermodynamic modeling and database development; 5) Molecular Dynamics (MD) study of clay

88

CAD Standards Guideline rev July 28, 2011 CAD Standards Guideline  

E-Print Network [OSTI]

CAD Standards Guideline rev July 28, 2011 1 CAD Standards;CAD Standards Guideline rev July 28, 2011 2 TABLE OF CONTENTS INTRODUCTION (pg.3) CAD Standards Survey/GIS Standards Design Standards 1.0.0 CAD STANDARDS CHECKLIST (pg.4) 2.0.0 CAD

Hanson, Stephen José

89

Design and Evaluation of Ionic Liquids as Novel Absorbents  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Design anD evaluation of ionic liquiDs Design anD evaluation of ionic liquiDs as novel absorbents Background There is growing concern among climate scientists that the buildup of greenhouse gases (GHG), particularly carbon dioxide (CO 2 ), in the atmosphere is affecting the global climate in ways that could have serious consequences. One approach to reducing GHG emissions is to scrub CO 2 from the flue gas of power plants and sequester it in geologic formations. Although it is technically feasible to remove CO 2 from flue gas, current processes are too expensive. New, less expensive processes are needed. This project is investigating the feasibility of using a novel class of compounds - ionic liquids - for the capture of CO 2 from the flue gas from coal and natural gas-fired power plants. The success of ionic liquids technology

90

Design and Evaluation of Daylighting Applications of Holographic Glazings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Design and Evaluation of Daylighting Applications of Holographic Glazings Design and Evaluation of Daylighting Applications of Holographic Glazings Title Design and Evaluation of Daylighting Applications of Holographic Glazings Publication Type Report LBNL Report Number LBNL-44167 Year of Publication 1996 Authors Papamichael, Konstantinos M., Charles K. Ehrlich, and Gregory J. Ward Call Number LBNL-44167 Abstract When combined with appropriate electric lighting dimming controls, the use of daylight for ambient and task illumination can significantly reduce energy requirements in commercial buildings. While skylights can effectively illuminate any part of one-story buildings, conventional side windows can illuminate only a 15 ft - 20 ft (4.6 m - 6.1 m) depth of the building perimeter. Even so, the overall efficacy of daylight is limited, because side windows produce uneven distributions of daylight. Achieving adequate illumination at distances further away from the window results in excessive illumination near the window, which increases cooling loads from the associated solar heat gain. As a result, the use of larger apertures and/or higher transmittance glazings, to introduce daylight deeper than 15 ft - 20 ft (4.6 m - 6.1 m), may prove ineffective with respect to saving energy, because cooling load penalties may exceed the electric lighting savings.

91

OPTIMIZATION AND DESIGN GUIDELINES FOR HIGH FLUX MICRO-CHANNEL HEAT SINKS FOR LIQUID AND GASEOUS SINGLE-PHASE FLOW  

E-Print Network [OSTI]

orders of magnitude, especially for high heat flux devices. Using water and air as coolants, designs with the optimization tool are generalized and optimum configurations are illustrated on design charts. Physical trends

Müller, Norbert

92

Resilient Plant Monitoring System: Design, Analysis, and Performance Evaluation  

SciTech Connect (OSTI)

Resilient monitoring systems are sensor networks that degrade gracefully under malicious attacks on their sensors, causing them to project misleading information. The goal of this paper is to design, analyze, and evaluate the performance of a resilient monitoring system intended to monitor plant conditions (normal or anomalous). The architecture developed consists of four layers: data quality assessment, process variable assessment, plant condition assessment, and sensor network adaptation. Each of these layers is analyzed by either analytical or numerical tools, and the performance of the overall system is evaluated using simulations. The measure of resiliency of the resulting system is evaluated using Kullback Leibler divergence, and is shown to be sufficiently high in all scenarios considered.

Humberto E. Garcia; Wen-Chiao Lin; Semyon M. Meerkov; Maruthi T. Ravichandran

2013-12-01T23:59:59.000Z

93

Fermilab Today - Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Subscribe | Contact Us | Archive | Classifieds | Guidelines | Help Search GO Fermilab Today - Guidelines Fermilab's Office of Communication publishes Fermilab Today each...

94

Evaluation of navy shipboard habitability for a warship design using human model  

Science Journals Connector (OSTI)

Recently, ergonomic design is a key issue in the warship design. Ergonomic ship design aims to improve the safety and convenience of crew and passengers. In this paper, as a basis of analyzing and evaluating ergonomic design criteria and evaluation methods ... Keywords: human model, shipboard habitability, warship design

Hongtae Kim; Jin H. Park; Hojin Hwang; Chang-Min Lee

2007-07-01T23:59:59.000Z

95

Roof and Attic Design Guidelines for new and retrofit Construction of Homes in Hot and Coild Climates  

SciTech Connect (OSTI)

Some guidelines for improving the energy efficiency of roofs and attics are presented and are based on the research of the DOE Building Technology. The results of combined analytical and experimental studies were used to benchmark computer tools, which in turn, were used to simulate homes in hot and cold climates. Adding floor and roof insulation, above deck ventilation, radiant barriers, cool color shingle, metal or tile roofs, sealing the attic floor, sealing the duct system and sealing the attic were simulated to compute the cost of energy savings. Results are prioritized to help building owners make an informed economic decision when contemplating roof and attic retrofits. Sealing the attic floor is a top retrofit option. The sealed attic approach and a new prototype roof assembly an insulated and ventilated roof are good options for retrofit work but have paybacks ranging from 15 to 25 years. A new sealed attic concept was simulated and computations show its simple payback is about 10 to 12 years in hot and cold climates; its first cost is significantly reduced from that of a spray foam approach. For new construction the best option is to keep the ducts out of the attic, make sure the attic floor is sealed and add at least code level of insulation to the ceiling.

Desjarlais, Andre Omer [ORNL] [ORNL; LaFrance, Marc [International Energy Agency] [International Energy Agency

2013-01-01T23:59:59.000Z

96

Brand Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

july 2012 molecular foundry brand guidelines Vision Our vision defines why we are here. We're here to provide support to researchers from around the world whose work can benefit from or contribute to nanoscience. Mission Our mission is the support that holds up our vision. Through unparalleled access to state-of-the-art instruments, materials, technical expertise, and training, the Molecular Foundry provides researchers with the tools to enhance the development and understanding of the synthesis, characterization, and theory of nanoscale materials. Values Our values are what we believe in. They define our success. People / Research / Collaboration / Enthusiasm Signature molecular foundry brand guidelines Signature :: 5 Signature :: Introduction The Molecular Foundry signature consists of the logotype in a fixed

97

TORIS Data Preparation Guidelines  

SciTech Connect (OSTI)

The objective of this manual is to present guidelines and procedures for the preparation of new data for the Tertiary Oil Recovery Information System (TORIS) data base. TORIS is an analytical system currently maintained by the Department of Energy's (DOE) Bartlesville Project Office. It uses an extensive field- and reservoir-level data base to evaluate the technical and economic recovery potential of specific crude oil reservoirs.

Guinn, H.; Remson, D.

1999-03-11T23:59:59.000Z

98

DOE-STD-3007-93 CN-1; DOE Standard Guidelines For Preparing Criticality Safety Evaluations at Department of Energy Non-Reactor Nuclear Facilities  

Broader source: Energy.gov (indexed) [DOE]

7-93 7-93 November 1993 CHANGE NOTICE NO. 1 September 1998 DOE STANDARD GUIDELINES FOR PREPARING CRITICALITY SAFETY EVALUATIONS AT DEPARTMENT OF ENERGY NON-REACTOR NUCLEAR FACILITIES U.S. Department of Energy AREA SAFT Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (423) 576-8401. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 605-6000. Order No. DE98003918 Change Notice No. 1 DOE-STD-3007-93 September 1998

99

Guidelines for degree designations at WVU Approved degree programs at WVU are listed in the WVU Curriculum Matrix, available at  

E-Print Network [OSTI]

refer to the combination of the degree designation and major (e.g., M.A. in Higher Education Administration rather than M.A. in Educational Leadership with a major in Higher Education Administration of Science (B.S.) Master of Arts (M.A.) Master of Science (M.S.) Doctor of Philosophy (Ph.D.) #12

Mohaghegh, Shahab

100

Weighted Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Weighted Guidelines Weighted Guidelines Weighted Guidelines More Documents & Publications Weighted Guidelines DOE F 4220.23 Microsoft Word - Final MR AL.doc...

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Total quality management implementation guidelines  

SciTech Connect (OSTI)

These Guidelines were designed by the Energy Quality Council to help managers and supervisors in the Department of Energy Complex bring Total Quality Management to their organizations. Because the Department is composed of a rich mixture of diverse organizations, each with its own distinctive culture and quality history, these Guidelines are intended to be adapted by users to meet the particular needs of their organizations. For example, for organizations that are well along on their quality journeys and may already have achieved quality results, these Guidelines will provide a consistent methodology and terminology reference to foster their alignment with the overall Energy quality initiative. For organizations that are just beginning their quality journeys, these Guidelines will serve as a startup manual on quality principles applied in the Energy context.

Not Available

1993-12-01T23:59:59.000Z

102

California Energy Commission GUIDELINES  

E-Print Network [OSTI]

Utilities Commission, CPUC, solar, solar energy systems, solar energy system incentive programsCalifornia Energy Commission GUIDELINES GUIDELINES FOR CALIFORNIA'S SOLAR guidelines for solar energy system incentive programs in California. The Senate Bill 1

103

Weighted Guidelines  

Broader source: Energy.gov (indexed) [DOE]

───────────────────────────────────Chapter 15.4-2 (July 2010) 1 Weighted Guidelines [References: FAR 15.4, DEAR 915.4] Overview This section provides guidance for applying the Department of Energy's (DOE) structured approach in determining profit/fee. Background The Federal Acquisition Regulation (FAR) requires consideration of certain factors (described in 15.404-4 as "profit-analysis factors" or "common factors") in developing a structured profit/fee approach. It does not prescribe specific government-wide procedures for profit/fee analysis. Actual profit/fee may vary (FAR 15.404-4(a) (1)) as you perform your profit/fee analysis;

104

Design and Evaluation of Novel High Capacity Cathode Materials...  

Broader source: Energy.gov (indexed) [DOE]

processing routes to prepare advanced electrodes with new architectural designs Use atomic-scale modeling as a guide to identify, design and understand the structural...

105

SunShot Initiative: Physics of Reliability: Evaluating Design Insights for  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Physics of Reliability: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar to someone by E-mail Share SunShot Initiative: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar on Facebook Tweet about SunShot Initiative: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar on Twitter Bookmark SunShot Initiative: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar on Google Bookmark SunShot Initiative: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar on Delicious Rank SunShot Initiative: Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar on Digg Find More places to share SunShot Initiative: Physics of

106

Survivability Design Principles for Enhanced Concept Generation and Evaluation  

E-Print Network [OSTI]

of design alternatives and to quickly screen a large number of candidate design variables before proceeding characterized by disturbances which may asymmetrically degrade performance, particularly for interdependent engineering concerned with minimizing the impact of environmental disturbances on system performance. Within

de Weck, Olivier L.

107

Designing CPV Receivers With Reliability: Early Evaluation of Components  

E-Print Network [OSTI]

. Everett, A. Blakers Centre for Sustainable Energy Systems, The Australian National University, Canberra: Early detection of performance issues allows more rapid & reliable design optimisation. Thermal. Ultra light-weight Fresnel mirror enclosed system. DESIGN RELIABILITY PRODUCTION Early detection

108

Special Issues for Program Design and Evaluation for Industrial Energy Programs  

E-Print Network [OSTI]

Designing energy efficiency programs that include serving industrial customers, and evaluating them, carries with it a set of challenges. A summary view from prior efficiency program evaluations will be presented that examines these challenges, how...

Megdal, L.

2007-01-01T23:59:59.000Z

109

Vehicle Technologies Office Merit Review 2014: Design and Evaluation of High Capacity Cathodes  

Broader source: Energy.gov [DOE]

Presentation given by Argonne National Laboratory at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about design and...

110

Supporting Information Evaluation of Flow field design in an Ammonium Bicarbonate  

E-Print Network [OSTI]

Supporting Information Evaluation of Flow field design in an Ammonium Bicarbonate Reverse Electrodialysis Stack Marta C. Hatzella , and Bruce E. Loganb* a Department of Mechanical and Nuclear Engineering

111

Design and Evaluation of Novel High Capacity Cathode Materials  

Broader source: Energy.gov [DOE]

2012 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting

112

Design and Evaluation of Novel High Capacity Cathode Materials  

Broader source: Energy.gov [DOE]

2011 DOE Hydrogen and Fuel Cells Program, and Vehicle Technologies Program Annual Merit Review and Peer Evaluation

113

Design and Evaluation of Novel High Capacity Cathode Materials...  

Broader source: Energy.gov (indexed) [DOE]

surface and bulk stability of electrodes at high electrochemical potentials Use atomic-scale modeling as a guide to identify, design and understand the structural...

114

Design and Evaluation of Novel High Capacity Cathode Materials  

Broader source: Energy.gov [DOE]

2009 DOE Hydrogen Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting, May 18-22, 2009 -- Washington D.C.

115

Design and Evaluation of Novel High Capacity Cathode Materials  

Broader source: Energy.gov [DOE]

2010 DOE Vehicle Technologies and Hydrogen Programs Annual Merit Review and Peer Evaluation Meeting, June 7-11, 2010 -- Washington D.C.

116

Evaluation and design of ventilation systems for autopsy and surgical examination tables  

E-Print Network [OSTI]

tests were used to determine the control characteristics of the initial LEV design. A proposed design was then evaluated and the results compared to the initial design with respect to fugitive emission control performance. The proposed design was a... grid plate design prevented the majority of air from being exhausted from the center of the table, therefore, creating uniform air distribution and, thus, an increase in fugitive emission control. The results from mannequin exposure monitoring...

Murgash, Mark John

2012-06-07T23:59:59.000Z

117

Design and Evaluation of Novel High Capacity Cathode Materials...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Merit Review and Peer Evaluation Meeting, June 7-11, 2010 -- Washington D.C. es017johnson2010o.pdf More Documents & Publications Lithium Source For High Performance Li-ion...

118

DESIGN AND EVALUATION OF A SAMPLER FOR MEASURING THE NEAR-BOTTOM VERTICAL DISTRIBUTION OF  

E-Print Network [OSTI]

DESIGN AND EVALUATION OF A SAMPLER FOR MEASURING THE NEAR-BOTTOM VERTICAL DISTRIBUTION OF PINK distribution of shrimp was considered essential to the design of an effective shrimp trawl since the vertical. Subsequently a multipurpose shrimp sampler was designed to facilitate investigation of shrimp distributions

119

Integrated support for working with guidelines: the Sherlock guideline management system  

Science Journals Connector (OSTI)

......Technology-Hellas Science and Technology...Sherlock Guideline Management System. Sherlock...phases. One recent approach in this direction...Sherlock Guideline Management System are presented...user interface management system, as well...recently as an approach to making designers......

D Grammenos; D Akoumianakis; C Stephanidis

2000-01-01T23:59:59.000Z

120

DEVELOPMENT OF A SUPPLEMENTAL RESIDUAL CONTAMINATION GUIDELINE  

Office of Legacy Management (LM)

DEVELOPMENT OF A SUPPLEMENTAL RESIDUAL CONTAMINATION GUIDELINE DEVELOPMENT OF A SUPPLEMENTAL RESIDUAL CONTAMINATION GUIDELINE FOR THE NFSS CENTRAL DRAINAGE DITCH DECEMBER 1986 Prepared for UNITED STATES DEPARTMENT OF ENERGY OAK RIDGE OPERATIONS OFFICE Under Contract No. DE-AC05-81OR20722 By Bechtel National, Inc. Oak Ridge, Tennessee Bechtel Job No. 14501 I 1.0 INTRODUCTION AND SUMMARY 1.1 OBJECTIVE AND SCOPE The objective of this report is to describe the methodology used for establishing a supplemental residual contamination guideline for the NFSS vicinity property known as the Central Drainage Ditch (CDD). Supplemental guidelines may exceed authorized guidelines if the resultant dose will not exceed the DOE radiation protection standard of 100 mrem/yr (Ref. 1). This evaluation is based on realistic exposure pathways that were

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

A Report to the Secretary of Energy, Beyond Design Basis Event Pilot Evaluations  

Broader source: Energy.gov (indexed) [DOE]

Beyond Design Basis Event Beyond Design Basis Event Pilot Evaluations Results and Recommendations for Improvements to Enhance Nuclear Safety at Department of Energy Nuclear Facilities Office of Nuclear Safety Office of Health, Safety and Security U.S. Department of Energy January 2013 Beyond Design Basis Event Pilot Evaluations TABLE OF CONTENTS Executive Summary i Acronyms iv 1.0 Introduction and Purpose 1 2.0 Background 2 3.0 Pilot Evaluations of Safety Analysis, NPH, and Emergency Management Guidance 2 4.0 Insights Gained from NRC and the Nuclear Community 11 5.0 Summary of Results and Recommendations 12 6.0 Conclusions 14 Appendix A - Pilot Evaluation Team Members 15 Beyond Design Basis Event Pilot Evaluations * i

122

Affordable solar home retrofit design and initial evaluation  

SciTech Connect (OSTI)

This paper describes the design construction and initial testing for a low cost live-in solar porch retrofit that has been developed by the Rural Housing Research Unit. The system was effective providing all the heat needed to keep the house warm during clear sunny winter days and it was effective in keeping the sun's energy out during summer periods.

Newman, J.O.; Newman, R.

1985-01-01T23:59:59.000Z

123

Job Counting Guidelines  

Broader source: Energy.gov (indexed) [DOE]

Environmental Management Environmental Management Definitions and Guidelines for Counting Monthly and Quarterly EM Recovery Act Full Time Equivalents (FTEs) and Cumulative Head-Count The following updated definitions and guidelines are intended to provide EM Recovery Act sites with information to collect and report timely and accurate full-time equivalent and cumulative head-count data for both monthly and quarterly jobs data calls. These revised guidelines supersede the previous monthly jobs data reporting definitions and guidelines dated February 9, 2010. These revised guidelines remain consistent with OMB guidance issued December 18, 2009 and cover subcontractors and vendors as well as prime

124

Integrated Technology Air Cleaners (ITAC): Design and Evaluation  

SciTech Connect (OSTI)

The primary objective of this project was to design, build, and test an air cleaner for residential use with the potential to substantially improve indoor air quality, or maintain indoor air quality unchanged, when outdoor air ventilation rates are reduced to save energy. Two air cleaners were designed and fabricated. The design targets for airflow rate, fan power, and projected cost were met. In short term laboratory studies, both units performed as expected; however, during field studies in homes, the formaldehyde removal performance of the air cleaners was much lower than expected. In subsequent laboratory studies, incomplete decomposition of some indoor air volatile organic compounds, with formaldehyde as a product of partial decomposition of volatile organic compounds, was confirmed as the explanation for the poor formaldehyde removal performance in the field studies. The amount of formaldehyde produced per unit of decomposition of other volatile organic compounds was substantially diminished by increasing the amount of catalyst on the filter and also by decreasing the air velocity. Together, these two measures reduced formaldehyde production, per unit destruction of other volatile organic compounds, by a factor of four, while increasing the removal efficiency of volatile organic compounds by a factor of 1.4. A company with a southern California office is conducting studies in conjunction with Lawrence Berkeley National Laboratory, with the goal of incorporating the ITAC catalytic air cleaning technology in their future commercial products.

Fisk, William J.; Cohn, Sebastian; Destaillats, Hugo; Henzel, Victor; Sidheswaran, Meera; Sullivan, Douglas P.

2013-09-13T23:59:59.000Z

125

Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar  

Broader source: Energy.gov [DOE]

The SunShot Physics of Reliability: Evaluating Design Insights for Component Technologies in Solar (PREDICTS) program is taking a physics- and chemistry-based approach to identifying failure modes...

126

Validation of and enhancements to an operating-speed-based geometric design consistency evaluation model  

E-Print Network [OSTI]

This thesis documents efforts to validate two elements related to an operating-speed-based geometric design consistency evaluation procedure: (1) the speed reduction estimation ability of the model, and (2) assumptions about acceleration...

Collins, Kent Michael

1995-01-01T23:59:59.000Z

127

The Design of Three-Dimensional Model for the Economic Evaluation of the Coal Enterprise Informationization  

Science Journals Connector (OSTI)

According to the coal enterprise characteristics and the current coal enterprise informationization construction circumstance, the author designed a three-dimensional model for the economic evaluation of the coal

Qing-wen Yuan; Shu-wei Yu

2013-01-01T23:59:59.000Z

128

Design and evaluation of large scale pultruded fiberglass tubular structures  

SciTech Connect (OSTI)

Large solid wood structures have been used in structural applications such as utility poles and marine pilings for a long time. A pultruded fiberglass reinforced polymer composite utility pole has been designed by the Composite Power Corporation of Las Vegas, Nevada which meets or exceeds the wood pole strength standards. This type of pole has many advantages over traditional wood, metal or concrete poles including: lighter weight, easier to climb and service, better dielectric and fire resistance properties, and it is more environmentally sound than treated wood poles. Utility crossarms, other attachments, and climbing devices are secured to grooves which run the entire length of the pole so there is no need to drill holes or wear spiked boots which would compromise the strength of the pole. Bending and torsion experiments have been conducted to determine if the present design meets the strength requirements of a forty foot Class one wood pole. Initial results of the composite pole tests showed a 17 percent advantage in bending strength, a 449 percent advantage in strength due to a vertical load applied to a crossarm, and a 43 percent advantage in twisting strength. Plans for further material characterization experiments and detailed stress and failure analysis are discussed.

O`Toole, B.J. [Univ. of Nevada, Las Vegas, NV (United States). Mechanical Engineering Department

1994-12-31T23:59:59.000Z

129

Protocol for Enhanced Evaluations of Beyond Design Basis Events Supporting Implementation of Operating Experience Report 2013-01  

Broader source: Energy.gov [DOE]

Protocol for Enhanced Evaluations of Beyond Design Basis Events Supporting Implementation of Operating Experience Report 2013-01

130

Design and Evaluation of an Integrated Planar Localization Method for Desktop Robotics  

E-Print Network [OSTI]

Design and Evaluation of an Integrated Planar Localization Method for Desktop Robotics Surya P. N- ment are critical aspects to the operation and control of mobile robots. The motion of desktop robots, a class of mobile robots designed for use on a table, can be consid- ered a special case of the general

Waldron, Kenneth J.

131

Radiological risk evaluation for risk-based design criteria of the multiple canister overpack packaging  

SciTech Connect (OSTI)

The Multiple Canister Overpack (MCO) cask will be used in the transportation of irradiated nuclear fuel from the K Basins to a Canister Storage Building. This report presents the radiological risk evaluation, which is used in the development of the design criteria for the MCO cask. The radiological risk evaluation ensures compliance with the onsite transportation safety program.

Green, J.R., Westinghouse Hanford

1996-07-18T23:59:59.000Z

132

Recommendations for Guidelines for EMF Personal Exposure Measurements, Rapid Project #4  

SciTech Connect (OSTI)

The purpose of developing guidelines for electric and magnetic field (EMF) personal exposure measurements (lF'EM) is to ensure reliable and comparable data across I?EM studies. Study techniques may vary due to different populations or objectives, but the resulting data should be consistently reported and comparable, to the extent possible. Any guideline must allow creativity by the research-oriented investigator and provide specific guidance to industrial hygienists or other results-oriented investigators, requiring a standard protocol. Recognizing measurement studies with different purposes is an important aspect of these recommendations. The guidelines presented here intend to produce comparable data across studies while remaining flexible. The recommendations for designing and implementing an EMF PEM program describe a three-stage process. The first step is to clearly state the purpose of the PEM program. The next stage addresses the fundamental elements of an EMF PEM study, including an assessment of the scientific and organizational resources that will be required. This process is codified in a written study plan. These stages are described in 1 Section 5 of this report. The third stage of a PEM study involves the design, implementation and documentation of specific procedures and protocols fo~ sampling strategies, selection of measurement parameters; instrumentation, measurement and data collection, data management, data analysis, quality assurance, uncertainty evaluation, and archiving the study methods and results. The methods for designing these elements of an EMF PEM study are described in Section 6: Specific Guidelines for EMF I?EM Study Design.

T. Dan Bracken, Inc.

1997-08-01T23:59:59.000Z

133

LSU Web Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Web Guidelines Colleges, Departments, Programs, and Projects Recruiting and promotional information published by officially recognized LSU offices, projects, or programs is...

134

Design Wise: A Guide for Evaluating the Interface Design of Information Resources, 1st edition  

Science Journals Connector (OSTI)

From the Publisher:The increased usage of computers and the Internet for accessing information, the drastic growth in end users, and the creation of more and more multimedia products has put a definite spin on the evaluation of information resources. ...

Alison J. Head

1999-04-01T23:59:59.000Z

135

Design Wise: A Guide for Evaluating the Interface Design of Information Resources  

Science Journals Connector (OSTI)

From the Publisher:The increased usage of computers and the Internet for accessing information, the drastic growth in end users, and the creation of more and more multimedia products has put a definite spin on the evaluation of information resources. ...

Alison J. Head

1999-06-01T23:59:59.000Z

136

GESDOR A Generic Execution Model for Sharing of Computer-Interpretable Clinical Practice Guidelines  

E-Print Network [OSTI]

Guideline Cough Guideline Breast Cancer Guideline Hypertension Guideline GLIF PROforma Guideline Instances

Peleg, Mor

137

NISTIR 7628 Guidelines for  

E-Print Network [OSTI]

NISTIR 7628 Guidelines for Smart Grid Cyber Security: Vol. 1, Smart Grid Cyber Security Strategy, Architecture, and High-Level Requirements The Smart Grid Interoperability Panel ­ Cyber Security Working Group August 2010 #12;NISTIR 7628 Guidelines for Smart Grid Cyber Security: Vol. 1, Smart Grid Cyber Security

138

NISTIR 7628 Guidelines for  

E-Print Network [OSTI]

NISTIR 7628 Guidelines for Smart Grid Cyber Security: Vol. 2, Privacy and the Smart Grid The Smart Grid Interoperability Panel ­ Cyber Security Working Group August 2010 #12;NISTIR 7628 Guidelines for Smart Grid Cyber Security: Vol. 2, Privacy and the Smart Grid The Smart Grid Interoperability Panel

139

NISTIR 7628 Guidelines for  

E-Print Network [OSTI]

NISTIR 7628 Guidelines for Smart Grid Cyber Security: Vol. 3, Supportive Analyses and References The Smart Grid Interoperability Panel ­ Cyber Security Working Group August 2010 #12;NISTIR 7628 Guidelines for Smart Grid Cyber Security: Vol. 3, Supportive Analyses and References The Smart Grid Interoperability

140

RECOMMENDED GUIDELINES FOR WASTEWATER CHARACTERIZATION  

E-Print Network [OSTI]

#12;RECOMMENDED GUIDELINES FOR WASTEWATER CHARACTERIZATION IN THE FRASER RIVER BASIN VOLUME II Ont. June 1993 Amended April 1994 #12;GUIDELINES FOR WASTEWATER CHARACTERIZATION PREFACE Ltd., Calgary, Alberta. #12;GUIDELINES FOR WASTEWATER CHARACTERIZATION EXECUTIVE SUMMARY The Fraser

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Postdoctoral Salary Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Salary Guidelines Salary Guidelines Postdoctoral Salary Guidelines Point your career towards LANL: work with the best minds on the planet in an inclusive environment that is rich in intellectual vitality and opportunities for growth. Contact Email How postdoc salaries are determined Annual starting salaries - Postdoctoral Fellows (Agnew, Director's, Entrepreneurial, Metropolis) and Postdoctoral Research Associates Competitive salaries are based on the date the PhD degree requirements were completed or the degree was awarded. On the anniversary of these dates, salaries are automatically adjusted to the next higher level. In addition, the guidelines are reviewed annually for possible adjustments. Starting salaries may vary from the guidelines up to a maximum of 25% due to market

142

Guidelines for Exposure Assessment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Z-92/001 Z-92/001 May 1992 Guidelines for Exposure Assessment Published on May 29, 1992, Federal Register 57(104):22888-22938 These guidelines replace the previously issued final Guidelines for Estimating Exposures (September 24, 1986), Federal Register 51(185):34042-34054, and the Proposed Guidelines for Exposure-Related Measurements (December 2, 1988), Federal Register 53(232):48830- 48853. Risk Assessment Forum U.S. Environmental Protection Agency Washington, DC DISCLAIMER This document has been reviewed in accordance with U.S. Environmental Protection Agency policy and approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use. Note: This document represents the final guidelines. A number of editorial corrections have

143

Strategy Guideline: HVAC Equipment Sizing  

SciTech Connect (OSTI)

The heating, ventilation, and air conditioning (HVAC) system is arguably the most complex system installed in a house and is a substantial component of the total house energy use. A right-sized HVAC system will provide the desired occupant comfort and will run efficiently. This Strategy Guideline discusses the information needed to initially select the equipment for a properly designed HVAC system. Right-sizing of an HVAC system involves the selection of equipment and the design of the air distribution system to meet the accurate predicted heating and cooling loads of the house. Right-sizing the HVAC system begins with an accurate understanding of the heating and cooling loads on a space; however, a full HVAC design involves more than just the load estimate calculation - the load calculation is the first step of the iterative HVAC design procedure. This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

Burdick, A.

2012-02-01T23:59:59.000Z

144

Module 10: Maintenance and Fueling Guidelines  

Broader source: Energy.gov [DOE]

This course covers safety guidelines for hydrogen, safe maintenance facilities, safety guidelines for hydrogen fueling facilities

145

Evaluation of Design Choices for Gang Scheduling using Distributed Hierarchical Control  

E-Print Network [OSTI]

Evaluation of Design Choices for Gang Scheduling using Distributed Hierarchical Control Dror G to control the adverse e ect of badly-matched gangs. Consequently the on-line mapping and scheduling, Israel Abstract Gang scheduling | the scheduling of a number of related threads to execute simultaneously

Feitelson, Dror

146

Computational Evaluation of a Transonic Laminar-Flow Wing Glove Design  

E-Print Network [OSTI]

2012 Major Subject: Aerospace Engineering iii ABSTRACT Computational Evaluation of a Transonic Laminar-Flow Wing Glove Design. (May 2012) Matthew William Roberts, B.S., Kansas State University Chair of Advisory Committee: Dr. Helen Reed... ............................................................................................................................ 1 A. Motivation ........................................................................................................................................ 1 B. Transition Mechanisms...

Roberts, Matthew William

2012-07-16T23:59:59.000Z

147

Evaluation and Design of Non-Lethal Laser Dazzlers Utilizing Microcontrollers  

E-Print Network [OSTI]

_________________________________ Dr. Carl Luchies _________________________________ Dr. Robert Umholtz Date Defended: December 3, 2012 ii The Thesis Committee for Keith Richardson certifies that this is the approved version of the following thesis...: EVALUATION AND DESIGN OF NON-LETHAL LASER DAZZLERS UTILIZING MICROCONTROLLERS _________________________________ Chairperson: Dr. Terry Faddis Date Approved: December 3, 2012 iii ABSTRACT Current non...

Richardson, Keith

2012-12-31T23:59:59.000Z

148

Design and Evaluation of a Virtual Experimental Environment for Distributed Systems  

E-Print Network [OSTI]

Design and Evaluation of a Virtual Experimental Environment for Distributed Systems Luc Sarzyniec described using a realistic topology model. Distem relies on LXC (Linux Containers), a low-overhead of virtual nodes. Distem provides a set of user interfaces to accomodate different needs (command- line

Paris-Sud XI, Université de

149

EVALUATION OF A PROTOTYPE SOLAR AWNING A prototype solar awning has been designed and installed on  

E-Print Network [OSTI]

and installed on a University of Oregon campus building. The solar awning is composed of a light shelfEVALUATION OF A PROTOTYPE SOLAR AWNING ABSTRACT A prototype solar awning has been designed with photovoltaic modules at- tached tilted 20° to the south. An interior light shelf and LED lights have been

Oregon, University of

150

ROM Design and Evaluation against Power Analysis Attack Huiyun Li, Simon Moore  

E-Print Network [OSTI]

ROM Design and Evaluation against Power Analysis Attack Huiyun Li, Simon Moore Computer Laboratory consumption of a normal ¢¡£ Read-only Memory(ROM) is simulated in HSPICE. Randomness is later inserted to mask the data-dependent information leakage. A dual-rail version of the ROM is then presented

Moore, Simon

151

Design, implementation and evaluation of a novel public display for pedestrian navigation: the rotating compass  

Science Journals Connector (OSTI)

Important drawbacks of map-based navigation applications for mobile phones are their small screen size and that users have to associate the information provided by the mobile phone with the real word. Therefore, we designed, implemented and evaluated ... Keywords: mobile navigation, public displays, synchronized displays

Enrico Rukzio; Michael Müller; Robert Hardy

2009-04-01T23:59:59.000Z

152

EV Guideline Assessment Templates  

Broader source: Energy.gov (indexed) [DOE]

EV Guideline Assessment Templates EV Guideline Assessment Templates |1. Process: Organization |2. Guideline No: 1|3. Contractor: |4.Contract/project(s): | ||||| ||||| |5. Guideline Statement: Define the authorized work elements for the program. A work breakdown structure (WBS), tailored for effective internal management control, is commonly used in this process. | || |6. Documentation Required: 1) CLINs 2) WBS 3) WBS Dictionary | || || || |7. Instructions: Why this is important: The WBS represents the entire scope of work in the project, a "picture" of the work. The first level is the total system, and it continues down in successively smaller elements until it reaches the level of detail necessary for management action and control. This picture of the work is needed to facilitate traceability, ensure the

153

ARM - Submitting Proposals : Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

govField CampaignsSubmitting Proposals : Guidelines govField CampaignsSubmitting Proposals : Guidelines Schedule and Availability Preproposals now open for AMF and AAF Preproposals due 1 Feb Invited full proposals due 1 May AAF available Dec 2015 AMF1 available Apr 2016 AMF2 available early 2017 AMF3 available for guest instrumentation or intensive operational periods Forms Propose a Campaign Form Instrument Support Request (ISR) Form (Word, 89KB) Documentation Steps to Send Campaign Data to ARM Data Archive Field Campaign Guidelines (PDF, 1.1MB) Submitting Proposals : Guidelines Proposals are welcome from all members of the scientific community for conducting field campaigns and scientific research using the ARM Climate Research Facility sites at the Southern Great Plains (SGP), North Slope of Alaska (NSA), Tropical Western Pacific (TWP), one of the ARM Mobile

154

GUIDELINES PROPOSITION 39: CALIFORNIA  

E-Print Network [OSTI]

GUIDELINES PROPOSITION 39: CALIFORNIA CLEAN ENERGY JOBS ACT - 2013 PROGRAM IMPLEMENTATION Utilities Commission. Keywords: Proposition 39, California Clean Energy Jobs Act, Job Creation Fund, Senate Bill 73, energy efficiency, clean energy, conservation, conservation corps

155

The Application of Reliability-Based Design Factors In Stress Corrosion Cracking Evaluations  

SciTech Connect (OSTI)

First-order reliability methodology (FORM) is used to develop reliability-based design factors for deterministic analyses of stress corrosion cracking. The basic elements of FORM as applied to structural reliability problems are reviewed and then employed specifically to stress corrosion cracking evaluations. Failure due to stress corrosion cracking is defined as crack initiation followed by crack growth to a critical depth. The stress corrosion cracking process is thus represented in terms of a crack initiation time model and a crack growth rate model, with the crack growth rate integrated from the initiation time to the time at which the crack grows to its critical depth. Both models are described by log-normal statistical distribution functions. A procedure is developed to evaluate design factors that are applied to the mean values of the crack initiation time and the crack growth rate for specified temperature and stress conditions. The design factors, which depend on the standard deviations of the statistical distributions, are related to a target reliability, which is inversely related to an acceptable probability of failure. The design factors are not fixed, but are evaluated on a case-to-case basis for each application. The use of these design factors in a deterministic analysis assures that the target reliability will be attained and the corresponding acceptable probability of failure will not be exceeded. An example problem illustrates use of this procedure.

E. Friedman

2001-12-20T23:59:59.000Z

156

Electrical safety guidelines  

SciTech Connect (OSTI)

The Electrical Safety Guidelines prescribes the DOE safety standards for DOE field offices or facilities involved in the use of electrical energy. It has been prepared to provide a uniform set of electrical safety standards and guidance for DOE installations in order to affect a reduction or elimination of risks associated with the use of electrical energy. The objectives of these guidelines are to enhance electrical safety awareness and mitigate electrical hazards to employees, the public, and the environment.

Not Available

1993-09-01T23:59:59.000Z

157

Tank exhaust comparison with 40 CFR 61.93, Subpart H, and other referenced guidelines for Tank Farms National Emission Standards for Hazardous Air Pollutant (NESHAP) designated stacks  

SciTech Connect (OSTI)

The US Environmental Protection Agency (EPA) promulgated National Emission Standards other than Radon from US Department of Energy (DOE) Facilities (40 CFR 61, Subpart H) on December 15, 1989. The regulations specify procedures, equipment, and test methods that.are to be used to measure radionuclide emissions from exhaust stacks that are designated as National Emission Standards for Hazardous Air Pollutant (NESHAP) stacks. Designated NESHAP stacks are those that have the potential to cause any member of the public to receive an effective dose equivalent (EDE) greater than or equal to 0.1 mrem/year, assuming all emission controls were removed. Tank Farms currently has 33 exhaust stacks, 15 of which are designated NESHAP stacks. This document assesses the compliance status of the monitoring and sampling systems for the designated NESHAP stacks.

Bachand, D.D.; Crummel, G.M.

1994-07-01T23:59:59.000Z

158

Natural phenomena hazards performance categorization guidelines for structures, systems, and components  

SciTech Connect (OSTI)

The Department of Energy (DOE) requires in DOE 5480.23 the use of a ``graded approach`` in performing safety analysis and evaluation of DOE facilities for normal operating and accident conditions, including accidents caused by natural phenomena hazard (NPH) events. DOE 5480.28 uses this graded approach and requires, for the purpose of NPH design and evaluation, placing the structures, systems, and components (SSCs) comprising the DOE facilities into five performance categories. This standard is a revision to DOE-STD-1021-92, December 1992, and provides guidelines to be used for such categorization of SSCs, and recommends systematic procedures to implement these guidelines. It applies to all DOE facilities that are covered by DOE 5480.28. (JDB)

Not Available

1993-07-01T23:59:59.000Z

159

Natural phenomena hazards performance categorization guidelines for structures, systems, and components  

SciTech Connect (OSTI)

The Department of Energy (DOE) requires in DOE 5480.23 the use of a graded approach'' in performing safety analysis and evaluation of DOE facilities for normal operating and accident conditions, including accidents caused by natural phenomena hazard (NPH) events. DOE 5480.28 uses this graded approach and requires, for the purpose of NPH design and evaluation, placing the structures, systems, and components (SSCs) comprising the DOE facilities into five performance categories. This standard is a revision to DOE-STD-1021-92, December 1992, and provides guidelines to be used for such categorization of SSCs, and recommends systematic procedures to implement these guidelines. It applies to all DOE facilities that are covered by DOE 5480.28. (JDB)

Not Available

1993-07-01T23:59:59.000Z

160

Policies, Procedures and Guidelines Complete Policy Title  

E-Print Network [OSTI]

Policies, Procedures and Guidelines Complete Policy Title: Faculty General Grievance Procedure. OBJECTIVE This Procedure is designed to provide McMaster faculty members with prompt and impartial by existing, specific review procedures. It is intended to facilitate and promote informal resolution

Haykin, Simon

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Applying Human Factors Evaluation and Design Guidance to a Nuclear Power Plant Digital Control System  

SciTech Connect (OSTI)

The United States (U.S.) nuclear industry, like similar process control industries, has moved toward upgrading its control rooms. The upgraded control rooms typically feature digital control system (DCS) displays embedded in the panels. These displays gather information from the system and represent that information on a single display surface. In this manner, the DCS combines many previously separate analog indicators and controls into a single digital display, whereby the operators can toggle between multiple windows to monitor and control different aspects of the plant. The design of the DCS depends on the function of the system it monitors, but revolves around presenting the information most germane to an operator at any point in time. DCSs require a carefully designed human system interface. This report centers on redesigning existing DCS displays for an example chemical volume control system (CVCS) at a U.S. nuclear power plant. The crucial nature of the CVCS, which controls coolant levels and boration in the primary system, requires a thorough human factors evaluation of its supporting DCS. The initial digital controls being developed for the DCSs tend to directly mimic the former analog controls. There are, however, unique operator interactions with a digital vs. analog interface, and the differences have not always been carefully factored in the translation of an analog interface to a replacement DCS. To ensure safety, efficiency, and usability of the emerging DCSs, a human factors usability evaluation was conducted on a CVCS DCS currently being used and refined at an existing U.S. nuclear power plant. Subject matter experts from process control engineering, software development, and human factors evaluated the DCS displays to document potential usability issues and propose design recommendations. The evaluation yielded 167 potential usability issues with the DCS. These issues should not be considered operator performance problems but rather opportunities identified by experts to improve upon the design of the DCS. A set of nine design recommendations was developed to address these potential issues. The design principles addressed the following areas: (1) color, (2) pop-up window structure, (3) navigation, (4) alarms, (5) process control diagram, (6) gestalt grouping, (7) typography, (8) terminology, and (9) data entry. Visuals illustrating the improved DCS displays accompany the design recommendations. These nine design principles serve as the starting point to a planned general DCS style guide that can be used across the U.S. nuclear industry to aid in the future design of effective DCS interfaces.

Thomas Ulrich; Ronald Boring; William Phoenix; Emily Dehority; Tim Whiting; Jonathan Morrell; Rhett Backstrom

2012-08-01T23:59:59.000Z

162

Medium-fi EvaluationMedium-fi PrototypesMedium-fi DesignLow-fi EvaluationLow-fi Prototypes What is Aphasia?  

E-Print Network [OSTI]

Medium-fi EvaluationMedium-fi PrototypesMedium-fi DesignLow-fi EvaluationLow-fi Prototypes What Cycle Investigated ability of existing technologies to fulfill needs. Extra time is needed to ensure. Evaluated with two participants. One had aphasia as a result of a brain tumour and the other as a result

Findlater, Leah

163

Evaluating approaches to product design and sourcing decisions in multinational companies  

Science Journals Connector (OSTI)

Product design and sourcing decisions are among the most difficult and important of all decisions facing multinational manufacturing companies, yet associated decision support and evaluation systems tend to be myopic in nature. Design for manufacture and assembly techniques, for example, generally focuses on manufacturing capability and ignores capacity although both should be considered. Similarly, most modelling and evaluation tools available to examine the performance of various solution and improvement techniques have a narrower scope than desired. A unique collaboration, funded by the US National Science Foundation, between researchers in the USA and the UK, currently addresses these problems. This paper describes a technique known as Design For the Existing Environment (DFEE) and an holistic evaluation system based on enterprise simulation that was used to demonstrate the business benefits of DFEE applied in a simple product development and manufacturing case study. A project that will extend these techniques to evaluate global product sourcing strategies is described along with the practical difficulties of building an enterprise simulation on the scale and detail required.

Doug Love; Jeff Barton; G. Don Taylor

2003-01-01T23:59:59.000Z

164

Measure Guideline: Three High Performance Mineral Fiber Insulation Board Retrofit Solutions  

SciTech Connect (OSTI)

This Measure Guideline describes a high performance enclosure retrofit package that uses mineral fiber insulation board. The Measure Guideline describes retrofit assembly and details for wood frame roof and walls and for cast concrete foundations. This Measure Guideline is intended to serve contractors and designers seeking guidance for non-foam exterior insulation retrofit.

Neuhauser, K.

2015-01-01T23:59:59.000Z

165

CRAD, Assessment Criteria and Guidelines for Determining the Adequacy of  

Broader source: Energy.gov (indexed) [DOE]

Assessment Criteria and Guidelines for Determining the Assessment Criteria and Guidelines for Determining the Adequacy of Software Used in the Safety Analysis and Design of Defense Nuclear Facilities CRAD, Assessment Criteria and Guidelines for Determining the Adequacy of Software Used in the Safety Analysis and Design of Defense Nuclear Facilities Performance Objective: These guidelines and criteria provide a consistent overall framework for assessment of the processes that are currently in place to ensure that the software being used in the safety analysis and design of the SSCs in defense nuclear facilities is adequate. These reviews will be conducted only on software that is currently in use, not on software that was previously used as part of a safety analysis and design process. Criteria: Custom software developed by DOE, its contractors, or subcontractors

166

Evaluation of a System Layer Design for the Visual Knowledge Builder  

E-Print Network [OSTI]

of MASTER OF SCIENCE Approved by: Chair of Committee, Frank M. Shipman Committee Members, Richard Furuta Ergun Akleman Head of Department, Duncan Walker December 2011 Major Subject: Computer Science iii ABSTRACT Evaluation of a System... Layer Design for the Visual Knowledge Builder. (December 2011) Arun Bharath Gomathinayagam, B. Tech, PSG College of Technology, Coimbatore, India Chair of Advisory Committee: Dr. Frank M. Shipman When users are searching for documents, they must...

Gomathinayagam, Arun Bharath

2012-02-14T23:59:59.000Z

167

Guidelines Volume II  

Gasoline and Diesel Fuel Update (EIA)

II II Sector-Specific Issues and Reporting Methodologies Supporting the General Guidelines for the Voluntary Reporting of Greenhouse Gases under Section 1605(b) of the Energy Policy Act of 1992 Part 4: Transportation Sector Part 5: Forestry Sector Part 6: Agricultural Sector Transportation Sector-Page 4.iii Contents of Volume II This volume, the second of two such volumes, contains sector-specific guidance in support of the General Guidelines for the voluntary reporting of greenhouse gas emissions and carbon sequestration. This voluntary reporting program was authorized by Congress in Section 1605(b) of the Energy Policy Act of 1992. The General Guidelines, bound separately from this volume, provide the overall rationale for the program, discuss in general how to analyze emissions and emission reduction/carbon sequestration projects, and

168

Guidelines Volume I  

Gasoline and Diesel Fuel Update (EIA)

I I Sector-Specific Issues and Reporting Methodologies Supporting the General Guidelines for the Voluntary Reporting of Greenhouse Gases under Section 1605(b) of the Energy Policy Act of 1992 Part 1: Electricity Supply Sector Part 2: Residential and Commercial Buildings Sector Part 3: Industrial Sector Electricity Supply Sector-Page 1.iii Contents of Volume I This volume, the first of two such volumes, contains sector-specific guidance in support of the General Guidelines for the voluntary reporting of greenhouse gas emissions and carbon sequestration. This voluntary reporting program was authorized by Congress in Section 1605(b) of the Energy Policy Act of 1992. The General Guidelines, bound separately from this volume, provide the overall rationale for the program,

169

CFO .:. Signature Authority Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Presentations Presentations Strategic Plan Ten Commandments Budget Office Business Systems Analysis Conference Services Controller's Office Field Operations Financial Policy & Assurance Human Resources in the OCFO Procurement & Property Office of Sponsored Projects & Industry Partnerships Training Travel Office spacer OCFO Home Send Feedback Signature Authority Guidelines LBNL Signature Authority Guidelines for Operational Transactions Signature Authorization System (SAS) Database in BRS: The Authorized Signers List can be found in the BLIS Reporting System (BRS) in the purchasing folder.You will need your LDAP username and password to access this database. Access the BLIS Reporting System (BRS) by clicking HERE. Delegation of Signature Authority Form: All requests for signature authority for Laboratory employees in the

170

Evaluation of alternative designs for engine-driven supermarket refrigeration. Final report, January-October 1990  

SciTech Connect (OSTI)

An assessment of several designs for gas engine-driven refrigeration systems for supermarkets is summarized. The objectives were to select the most viable alternative for a refrigeration system, to identify the potential market acceptance, and to define a feasible development and commercialization path for the most attractive system. The project included a telephone survey of supermarket engineering management to characterize current practices and equipment selection criteria, the development of preliminary designs for four principal system alternatives, and an evaluation of the economics of the system alternatives based on climate and energy rate data for Atlanta, Chicago, Los Angeles, and Phoenix. Of the four alternatives, one was unintegrated straight cogeneration and three were integrated cogeneration/refrigeration designs.

Griffiths, D.; Darrow, K.; Parkhurst, B.

1991-01-01T23:59:59.000Z

171

Evaluation of a New Remote Handling Design for High Throughput Annular Centrifugal Contactors  

SciTech Connect (OSTI)

Advanced designs of nuclear fuel recycling plants are expected to include more ambitious goals for aqueous based separations including; higher separations efficiency, high-level waste minimization, and a greater focus on continuous processes to minimize cost and footprint. Therefore, Annular Centrifugal Contactors (ACCs) are destined to play a more important role for such future processing schemes. Previous efforts defined and characterized the performance of commercial 5 cm and 12.5 cm single-stage ACCs in a “cold” environment. The next logical step, the design and evaluation of remote capable pilot scale ACCs in a “hot” or radioactive environment was reported earlier. This report includes the development of remote designs for ACCs that can process the large throughput rates needed in future nuclear fuel recycling plants. Novel designs were developed for the remote interconnection of contactor units, clean-in-place and drain connections, and a new solids removal collection chamber. A three stage, 12.5 cm diameter rotor module has been constructed and evaluated for operational function and remote handling in highly radioactive environments. This design is scalable to commercial CINC ACC models from V-05 to V-20 with total throughput rates ranging from 20 to 650 liters per minute. The V-05R three stage prototype was manufactured by the commercial vendor for ACCs in the U.S., CINC mfg. It employs three standard V-05 clean-in-place (CIP) units modified for remote service and replacement via new methods of connection for solution inlets, outlets, drain and CIP. Hydraulic testing and functional checks were successfully conducted and then the prototype was evaluated for remote handling and maintenance suitability. Removal and replacement of the center position V-05R ACC unit in the three stage prototype was demonstrated using an overhead rail mounted PaR manipulator. This evaluation confirmed the efficacy of this innovative design for interconnecting and cleaning individual stages while retaining the benefits of commercially reliable ACC equipment for remote applications in the nuclear industry. Minor modifications and suggestions for improved manual remote servicing by the remote handling specialists were provided but successful removal and replacement was demonstrated in the first prototype.

David H. Meikrantz; Troy G. Garn; Jack D. Law; Lawrence L. Macaluso

2009-09-01T23:59:59.000Z

172

The University Advertising Guidelines  

E-Print Network [OSTI]

advertisements 21 A4 advertisements with image 22 On-line ­ brand advertising 23 On-line leaderboards and MPUs to these on page 48 in the Heriot-Watt University brand guidelines. Images Images should use the whole area) advertisements 6 Small space (5cms x 2cols) advertisements with image 8 A5 advertisements 9 A5 advertisements

Painter, Kevin

173

Operating Guidelines Narrative.DOC  

Broader source: Energy.gov (indexed) [DOE]

Competitive Sourcing Program Operating Guidelines Issued under authority of: Competitive Sourcing Executive Steering Group July 1, 2004 DOE Competitive Sourcing Program OPERATING GUIDELINES (CS-OG-01) i COMPETITIVE SOURCING PROGRAM OPERATING GUIDELINES Table of Contents 1. REFERENCES ................................................................................................................................... 1 2. PURPOSE ........................................................................................................................................... 1 3. APPLICABILITY AND SCOPE ......................................................................................................

174

Operating Guidelines Narrative.DOC  

Broader source: Energy.gov (indexed) [DOE]

Competitive Sourcing Program Operating Guidelines Issued under authority of: Competitive Sourcing Executive Steering Group July 1, 2004 DOE Competitive Sourcing Program OPERATING GUIDELINES (CS-OG-01) i COMPETITIVE SOURCING PROGRAM OPERATING GUIDELINES Table of Contents 1. REFERENCES ................................................................................................................................... 1 2. PURPOSE ........................................................................................................................................... 1 3. APPLICABILITY AND SCOPE ......................................................................................................

175

Interconnection Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Interconnection Guidelines Interconnection Guidelines Interconnection Guidelines < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Wind Energy Sources Solar Home Weatherization Water Program Info State South Carolina Program Type Interconnection Provider Public Service Commission of South Carolina The South Carolina Public Service Commission (PSC) adopted simplified interconnection guidelines for small distributed generation (DG) in December 2006. These guidelines address renewable-energy systems and other forms of DG up to 20 kilowatts (kW) in capacity for residential systems,

176

Super Energy Efficiency Design (S.E.E.D.) Home Evaluation  

SciTech Connect (OSTI)

This report describes the results of evaluation by the Alliance for Residential Building Innovation (ARBI) Building America team of the 'Super Energy Efficient Design' (S.E.E.D) home, a 1,935 sq. ft., single-story spec home located in Tucson, AZ. This prototype design was developed with the goal of providing an exceptionally energy efficient yet affordable home and includes numerous aggressive energy features intended to significantly reduce heating and cooling loads such as structural insulated panel (SIP) walls and roof, high performance windows, an ERV, an air-to-water heat pump with mixed-mode radiant and forced air delivery, solar water heating, and rooftop PV. Source energy savings are estimated at 45% over the Building America B10 Benchmark. System commissioning, short term testing, long term monitoring and detailed analysis of results was conducted to identify the performance attributes and cost effectiveness of the whole house measure package.

German, A.; Dakin, B.; Backman, C.; Weitzel, E.; Springer, D.

2012-12-01T23:59:59.000Z

177

Thermal design and preliminary performance evaluation of the cooling system for BaR-SPOrt  

Science Journals Connector (OSTI)

BaR-SPOrt is an experiment to measure the linearly polarized emission of 20°×20° sky patches at 32 GHz and 90 GHz from a stratospheric balloon. It consists of correlation polarimeters for direct measurements of the Q and U Stokes parameters coupled to an optics providing a beam of 0°.5 (32 GHz) and 0°.2 (90 GHz). Its aim is the study of the polarization of the Diffused Galactic Background as well as the Cosmic Microwave Background Radiation (CMBR). The instrument thermal design and the preliminary performance evaluation of the cooling system are described.

C. Macculi; M. Zannoni

2002-01-01T23:59:59.000Z

178

Inside RHIC | Submission Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Submission Guidelines Submission Guidelines "Inside RHIC" is an online publication covering news and views of the RHIC and AGS program at Brookhaven National Laboratory at the level of engineers and students. The RHIC AGS Users Group is sponsoring this effort, and we have tried to cover the breadth of the efforts at RHIC, from physics results to machine and detector development. The articles are relatively short and not so technical; a few hundred words are enough. It is a web publication, so length is not critical, but it is better to be concise. If you write an article for RHIC News, here's what is needed: The text of the article (a plain ASCII text file is adequate, even preferable, although we can deal with almost any format) The first few sentences (maybe 100 words) should summarize the point

179

gas cylinder storage guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Compressed Gas Cylinder Storage Guidelines Compressed Gas Cylinder Storage Guidelines All cylinders must be stored vertical, top up across the upper half the cylinder but below the shoulder. Small cylinder stands or other methods may be appropriate to ensure that the cylinders are secured from movement. Boxes, cartons, and other items used to support small cylinders must not allow water to accumulate and possible cause corrosion. Avoid corrosive chemicals including salt and fumes - keep away from direct sunlight and keep objects away that could fall on them. Use Gas pressure regulators that have been inspected in the last 5 years. Cylinders that contain fuel gases whether full or empty must be stored away from oxidizer cylinders at a minimum of 20 feet. In the event they are stored together, they must be separated by a wall 5 feet high with

180

Glove Selection Guideline  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Glove Selection Guideline Glove Selection Guideline Skin contact is a potential source of exposure to toxic materials; it is important that the proper steps be taken to prevent such contact. Most accidents involving hands and arms can be classified under four main hazard categories: chemicals, abrasions, cutting, and heat. There are gloves available that can protect workers from any of these individual hazards or any combination thereof. Gloves should be replaced periodically, depending on frequency of use and permeability to the substance(s) handled. Gloves overtly contaminated should be rinsed and then carefully removed after use. Gloves should also be worn whenever it is necessary to handle rough or sharp-edged objects, and very hot or very cold materials. The type of glove materials to be used in these situations include leather, welderÂ’s gloves,

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Rewards & pitfalls of using treating pressure analysis for evaluating fracture design  

SciTech Connect (OSTI)

Analyzing pressures during a fracture treatment provides insight into the hydraulic fracturing process, and is widely used today. In this paper, case histories are reviewed and guidelines are presented to identify pitfalls and establish strategies in pressure-analysis methods and procedures.

Cramer, D.D.

1996-12-31T23:59:59.000Z

182

Preliminary Evaluation of Alternate Designs for HFIR Low-Enriched Uranium Fuel  

SciTech Connect (OSTI)

Engineering design studies of the feasibility of conversion of the High Flux Isotope Reactor (HFIR) from high-enriched uranium (HEU) to low-enriched uranium (LEU) fuel are ongoing at Oak Ridge National Laboratory (ORNL) as part of an effort sponsored by the U.S. Department of Energy’s Global Threat Reduction Initiative (GTRI)/Reduced Enrichment for Research and Test Reactors (RERTR) program. The fuel type selected by the program for the conversion of the five high-power research reactors in the U.S. that still use HEU fuel is a new U-Mo monolithic fuel. Studies by ORNL have previously indicated that HFIR can be successfully converted using the new fuel provided (1) the reactor power can be increased from 85 MW to 100 MW and (2) the fuel can be fabricated to a specific reference design. Fabrication techniques for the new fuel are under development by the program but are still immature, especially for the “complex” aspects of the HFIR fuel design. In FY 2012, the program underwent a major shift in focus to emphasize developing and qualifying processes for the fabrication of reliable and affordable LEU fuel. In support of this new focus and in an effort to ensure that the HFIR fuel design is as suitable for reliable fabrication as possible, ORNL undertook the present study to propose and evaluate several alternative design features. These features include (1) eliminating the fuel zone axial contouring in the previous reference design by substituting a permanent neutron absorber in the lower unfueled region of all of the fuel plates, (2) relocating the burnable neutron absorber from the fuel plates of the inner fuel element to the side plates of the inner fuel element (the fuel plates of the outer fuel element do not contain a burnable absorber), (3) relocating the fuel zone inside the fuel plate to be centered on the centerline of the depth of the plate, and (4) reshaping the radial contour of the relocated fuel zone to be symmetric about this centerline. The present studies used current analytical tools to evaluate the various alternate designs for cycle length, scientific performance (e.g., neutron scattering), and steady-state and transient thermal performance using both safety limit and nominal parameter assumptions. The studies concluded that a new reference design combining a permanent absorber in the lower unfueled region of all of the fuel plates, a burnable absorber in the inner element side plates, and a relocated and reshaped (but still radially contoured) fuel zone will allow successful conversion of HFIR. Future collaboration with the program will reveal whether the new reference design can be fabricated reliably and affordably. Following this feedback, additional studies using state-of-the-art developmental analytical tools are proposed to optimize the design of the fuel zone radial contour and the amount and location of both types of neutron absorbers to further flatten thermal peaks while maximizing the performance of the reactor.

Renfro, David [ORNL; Chandler, David [ORNL; Cook, David [ORNL; Ilas, Germina [ORNL; Jain, Prashant [ORNL; Valentine, Jennifer [ORNL

2014-10-30T23:59:59.000Z

183

Methodologies and new user interfaces to optimize hydraulic fracturing design and evaluate fracturing performance for gas wells  

E-Print Network [OSTI]

This thesis presents and develops efficient and effective methodologies for optimal hydraulic fracture design and fracture performance evaluation. These methods incorporate algorithms that simultaneously optimize all of the treatment parameters...

Wang, Wenxin

2006-04-12T23:59:59.000Z

184

The human factors of sustainable building design: post occupancy evaluation of the Philip Merrill Environmental Center  

E-Print Network [OSTI]

believed that sustainable building design strategies createexperience of a building. For sustainable design, these

Heerwagen, J.; Zagreus, Leah

2005-01-01T23:59:59.000Z

185

A manual for implementing residual radioactive material guidelines  

SciTech Connect (OSTI)

This manual presents information for implementing US Department of Energy (DOE) guidelines for residual radioactive material at sites identified by the Formerly Utilized Sites Remedial Action Program (FUSRAP) and the Surplus Facilities Management Program (SFMP). It describes the analysis and models used to derive site-specific guidelines for allowable residual concentrations of radionuclides in soil and the design and use of the RESRAD computer code for calculating guideline values. It also describes procedures for implementing DOE policy for reducing residual radioactivity to levels that are as low as reasonably achievable. 36 refs., 16 figs, 22 tabs.

Gilbert, T.L.; Yu, C.; Yuan, Y.C.; Zielen, A.J.; Jusko, M.J.; Wallo, A. III

1989-06-01T23:59:59.000Z

186

Using modeling to design and evaluate transient open ocean iron enrichment for carbon sequestration  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Using modeling to design and evaluate Using modeling to design and evaluate transient open ocean iron enrichment for carbon sequestration Richard T. Barber (rbarber@duke.edu; 252-504-7578) Duke University Marine Laboratory 135 Duke Marine Lab Road Beaufort, NC 28516-9721 Fei Chai (fchai@maine.edu; 207-581-4317) University of Maine School of Marine Sciences 5741 Libby Hall Orono, ME 04469-5741 Introduction During the 1990s the rate of increase of CO 2 in the atmosphere was about 3.5 Pg C y -1 . Total emissions were 7.4 Pg C y -1 , so about 3.9 Pg C y -1 (52% of total emissions) were sequestered naturally. Of this, about 2.2 Pg C y -1 was absorbed by the oceans and 1.7 Pg C y -1 by the land (US DOE, 1999). The Kyoto Protocol of 1997 calls for a 34% reduction of emissions by 2050 and a reduction of 70% from the projected emissions at 2100. The major approach to

187

Design, Implementation, and Evaluation of a Hybrid DS/FFH Spread-Spectrum Radio Transceiver  

SciTech Connect (OSTI)

In recent years there has been great interest in using hybrid spread-spectrum (HSS) techniques for commercial applications, particularly in the Smart Grid, in addition to their inherent uses in military communications. This is because HSS can accommodate high data rates with high link integrity, even in the presence of significant multipath effects and interfering signals. A highly useful form of this transmission technique for many types of command, control, and sensing applications is the specific code-related combination of standard direct-sequence modulation with "fast" frequency-hopping, denoted hybrid DS/FFH, wherein multiple frequency hops occur within a single data-bit time. In this paper, we present the efforts carried out at Oak Ridge National Laboratory toward exploring the design, implementation, and evaluation of a hybrid DS/FFH spread-spectrum radio transceiver using a single Field Programmable Gate Array (FPGA). The FPGA allows the various subsystems to quickly communicate with each other and thereby maintain tight synchronization. We also investigate various hopping sequences against robustness to interference and jamming. Experimental results are presented that show the receiver sensitivity, radio data-rate/bit-error evaluations, and jamming and interference rejection capabilities of the implemented hybrid DS/FFH spread-spectrum system under widely varying design parameters.

Olama, Mohammed M [ORNL; Killough, Stephen M [ORNL; Kuruganti, Teja [ORNL; Carroll, Thomas E. [Pacific Northwest National Laboratory (PNNL)

2014-01-01T23:59:59.000Z

188

Control-Alt-Hack: The Design and Evaluation of a Card Game for Computer Security Awareness and Education  

E-Print Network [OSTI]

Control-Alt-Hack: The Design and Evaluation of a Card Game for Computer Security Awareness from 22 of these educators about their experiences using Control-Alt-Hack with over 450 students to thinking about security and that facilitates ad hoc, social interactions led us to design Control-Alt-Hack

Kohno, Tadayoshi

189

Design and Evaluation of a Feedback Control EDF Scheduling Supported in part by NSF grant CCR-9901706 and contract IJRP-  

E-Print Network [OSTI]

Design and Evaluation of a Feedback Control EDF Scheduling Algorithm* * Supported in part by NSF. In this paper, we present a feedback control real-time scheduling algorithm and its evaluation. Performance}@cs.virginia.edu, gt9s@virginia.edu Abstract Despite the significant body of results in real-time scheduling, many real

Lu, Chenyang

190

APS Safety Guidelines for Beamlines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Safety Guidelines for Beamlines Accident Investigations LOM Shop Usage User Shop Access - Policies and Procedures User Shop Orientation User Shop Authorization Certification Form...

191

Leadership in Energy and Environmental Design (LEED) - A critical evaluation by LCA and recommendations for improvement  

E-Print Network [OSTI]

performance, sustainable buildings. A building design can bebuilding LEED credit (summary) Sustainable Sites (SS) Prerequisite 1: Design

Humbert, Sebastien; Abeck, Heike; Bali, Nishil; Horvath, Arpad

2007-01-01T23:59:59.000Z

192

Natural Phenomena Hazards Design and Evaluation Criteria for Department of Energy Facilities  

Broader source: Energy.gov (indexed) [DOE]

0-2002 0-2002 January 2002 Superseding DOE-STD-1020-94 April 1994 DOE STANDARD NATURAL PHENOMENA HAZARDS DESIGN AND EVALUATION CRITERIA FOR DEPARTMENT OF ENERGY FACILITIES U.S. Department of Energy AREA NPHZ Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. TS This document has been reproduced from the best available copy. Available to DOE and DOE contractors from ES&H Technical Information Services, U.S. Department of Energy, (800) 473-4375, fax: (301) 903-9823. Available to the public from the U.S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA 22161; (703) 605-6000. DOE-STD-1020-2002 iii Foreword This revision provides information to help meet the requirements of 10 CFR Part 830, "Nuclear

193

APS Preliminary Beamline Design Report Guide  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

PRELIMINARY BEAMLINE DESIGN REPORT PRELIMINARY BEAMLINE DESIGN REPORT December 5, 1994 5.1 Preliminary Beamline Design: General Guidelines The Preliminary Design of the beamline represents an approximately 30% design level of each of the beamline components. This level of design permits the CAT to develop cost estimates for the construction of the beamline, as well as a realistic timeline for completion of the construction tasks. A committee from the APS has been charged with reviewing the Preliminary Design Reports and has established the evaluation criteria described below. The Preliminary Beamline Report is expected to expand upon the Conceptual Design Report in the following areas: Beamline Layout Component Design Work Breakdown Structure Cost and Schedule Additional Operational Requirements

194

Simplified design and evaluation of liquid storage tanks relative to earthquake loading  

SciTech Connect (OSTI)

A summary of earthquake-induced damage in liquid storage tanks is provided. The general analysis steps for dynamic response of fluid-filled tanks subject to horizontal ground excitation are discussed. This work will provide major attention to the understanding of observed tank-failure modes. These modes are quite diverse in nature, but many of the commonly appearing patterns are believed to be shell buckling. A generalized and simple-to-apply shell loading will be developed using Fluegge shell theory. The input to this simplified analysis will be horizontal ground acceleration and tank shell form parameters. A dimensionless parameter will be developed and used in predictions of buckling resulting from earthquake-imposed loads. This prediction method will be applied to various tank designs that have failed during major earthquakes and during shaker table tests. Tanks that have not failed will also be reviewed. A simplified approach will be discussed for early design and evaluation of tank shell parameters and materials to provide a high confidence of low probability of failure during earthquakes.

Poole, A.B.

1994-06-01T23:59:59.000Z

195

Postdoctoral program guidelines.  

SciTech Connect (OSTI)

We, the Postdoc Professional Development Program (PD2P) leadership team, wrote these postdoc guidelines to be a starting point for communication between new postdocs, their staff mentors, and their managers. These guidelines detail expectations and responsibilities of the three parties, as well as list relevant contacts. The purpose of the Postdoc Program is to bring in talented, creative people who enrich Sandia's environment by performing innovative R&D, as well as by stimulating intellectual curiosity and learning. Postdocs are temporary employees who come to Sandia for career development and advancement reasons. In general, the postdoc term is 1 year, renewable up to five times for a total of six years. However, center practices may vary; check with your manager. At term, a postdoc may apply for a staff position at Sandia or choose to move to university, industry or another lab. It is our vision that those who leave become long-term collaborators and advocates whose relationships with Sandia have a positive effect upon our national constituency.

Teich-McGoldrick, Stephanie; Miller, Andrew W.; Sava, Dorina Florentina; Liu, Yanli; Ferreira, Summer Rhodes; Biedermann, Laura Butler; Cruz-Campa, Jose Luis; Hall, Lisa Michelle; Liu, Xiaohua H.; Ekoto, Isaac

2012-04-01T23:59:59.000Z

196

A design-for-environment study for plating processes -- Evaluations of wastewater precipitation and separation technologies  

SciTech Connect (OSTI)

A wastewater pollution prevention study was performed for two plating processes. This study included wastewater precipitation process analysis, and evaluation of separation and recycling alternatives. The pollution prevention opportunity assessment goals are: to reduce and reuse wastewater, to develop a design-for-environment plating process, and to conduct a material life-cycle analysis (LCA) for selected materials and with well-defined boundary. From an analysis of coordination chemistry and a series of precipitation process tests, it was found that treatment with optimized pH and mixing rate, proper coprecipitants (such as iron salts), and chemical dosages were needed to dissociate metal ions from the chelated complexes (Cu-EDTA) in the wastewater. In this study, reverse osmosis and ion exchange, separation/recycling technologies were also evaluated. A water reclamation project with these two technologies was implemented. The analysis indicated, that with recycling systems, 33% of the wastewater could be reclaimed and more than 90% of reduction of copper in wastewater was achieved. With the LCA, a greener approach was implemented to reduce the wasted parts disposal problems.

Chang, L.Y. [Lawrence Berkeley National Lab., CA (United States)

1995-12-31T23:59:59.000Z

197

SOCIAL MEDIA VISUAL IDENTITY GUIDELINES  

E-Print Network [OSTI]

SOCIAL MEDIA VISUAL IDENTITY GUIDELINES VERSION 1.2 Last updated by Web Strategies on 08 July 2011. Contact: Web Strategies, webadmin@ohsu.edu #12;2 OHSU UNIfIED SITE SOCIAL MEDIA VISUAL IDENTITY GUIDELINES OHSU Web Strategies - www.ohsu.edu/webstrategies/ pURpOSE This document presents the official visual

Chapman, Michael S.

198

NIST Finalizes Initial Set of Smart Grid Cyber Security Guidelines |  

Broader source: Energy.gov (indexed) [DOE]

NIST Finalizes Initial Set of Smart Grid Cyber Security Guidelines NIST Finalizes Initial Set of Smart Grid Cyber Security Guidelines NIST Finalizes Initial Set of Smart Grid Cyber Security Guidelines September 2, 2010 - 3:15pm Addthis WASHINGTON, D.C. - The National Institute of Standards and Technology (NIST) issued today its first Guidelines for Smart Grid Cyber Security, which includes high-level security requirements, a framework for assessing risks, an evaluation of privacy issues at personal residences, and additional information for businesses and organizations to use as they craft strategies to protect the modernizing power grid from attacks, malicious code, cascading errors, and other threats. The product of two formal public reviews and the focus of numerous workshops and teleconferences over the past 17 months, the three-volume set

199

Light Water Reactor Sustainability Program Operator Performance Metrics for Control Room Modernization: A Practical Guide for Early Design Evaluation  

SciTech Connect (OSTI)

As control rooms are modernized with new digital systems at nuclear power plants, it is necessary to evaluate the operator performance using these systems as part of a verification and validation process. There are no standard, predefined metrics available for assessing what is satisfactory operator interaction with new systems, especially during the early design stages of a new system. This report identifies the process and metrics for evaluating human system interfaces as part of control room modernization. The report includes background information on design and evaluation, a thorough discussion of human performance measures, and a practical example of how the process and metrics have been used as part of a turbine control system upgrade during the formative stages of design. The process and metrics are geared toward generalizability to other applications and serve as a template for utilities undertaking their own control room modernization activities.

Ronald Boring; Roger Lew; Thomas Ulrich; Jeffrey Joe

2014-03-01T23:59:59.000Z

200

Design and Evaluation of a Net Zero Energy Low-Income Residential Housing Development in Lafayette, Colorado  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Design and Evaluation of a Design and Evaluation of a Net Zero Energy Low-Income Residential Housing Development in Lafayette, Colorado Jesse Dean and Otto VanGeet National Renewable Energy Laboratory Scott Simkus Boulder County Housing Authority Mark Eastment Mountain Energy Partnership Technical Report NREL/TP-7A40-51450 March 2012 NREL is a national laboratory of the U.S. Department of Energy, Office of Energy Efficiency & Renewable Energy, operated by the Alliance for Sustainable Energy, LLC. National Renewable Energy Laboratory 1617 Cole Boulevard Golden, Colorado 80401 303-275-3000 * www.nrel.gov Contract No. DE-AC36-08GO28308 Design and Evaluation of a Net Zero Energy Low-Income Residential Housing Development in Lafayette,

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Critical Simulation Based Evaluation of Thermally Activated Building Systems (TABS) Design Models  

E-Print Network [OSTI]

4.7. Discomfort distribution on a design day as Occupancy4.8. Discomfort distribution on a design day as Occupancy4.7. Discomfort distribution on a design day as Occupancy

Basu, Chandrayee

2012-01-01T23:59:59.000Z

202

CSLC Application Guidelines | Open Energy Information  

Open Energy Info (EERE)

GuidelinesLegal Abstract CSLC Application Guidelines, current through August 5, 2014. Published NA Year Signed or Took Effect 2014 Legal Citation California State Lands...

203

Computer System Retirement Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Computer System Retirement Guidelines Computer System Retirement Guidelines The System Retirement template contains DOE headquarters-specific information that may be adapted for...

204

Request For Information Regarding Categorical Exclusions: Guidelines...  

Broader source: Energy.gov (indexed) [DOE]

Exclusions: Guidelines Request For Information Regarding Categorical Exclusions: Guidelines The U.S. Department of Energy (DOE) intends to update its National Environmental Policy...

205

NMOSE Basin Guidelines | Open Energy Information  

Open Energy Info (EERE)

OtherOther: NMOSE Basin GuidelinesLegal Abstract The New Mexico Office of the State Engineer (NMOSE) provides links to final rules and administrative guidelines for particular...

206

Design, construction, operation and evaluation of a prototype culm combustion boiler/heater unit. Final design of prototype unit  

SciTech Connect (OSTI)

A final design of a prototype anthracite culm combustion boiler has been accomplished under Phase I of DOE Contract ET-78-C-01-3269. The prototype boiler has been designed to generate 20,000 pounds per hour of 150 psig saturated steam using low Btu (4000 Btu per pound) anthracite culm as a fuel. This boiler will be located at the industrial park of the Shamokin Area Industrial Corporation (SAIC). This program is directed at demonstrating the commercial viability of anthracite culm fueled FBC steam generation systems.

Not Available

1980-10-01T23:59:59.000Z

207

Design study and comparative evaluation of JSFR failed fuel detection system  

SciTech Connect (OSTI)

A conceptual design study of an advanced sodium-cooled fast reactor JSFR has progressed in the 'Fast Reactor Cycle Technology Development (FaCT) 'project in Japan. JSFR has two failed fuel detection systems in the core. One is a failed fuel detection (FFD) system which continuously monitors a fission product from failed fuel subassembly. The other is a failed fuel detection and location (FFDL) system which locates when it receives signals from FFD. The FFD system consists of a FFD-DN which detects delayed neutron (DN) in sodium and a FFD-CG which detects fission products in the cover gas of the reactor vessel. In this study, requirements to the FFD-DN and the FFD-DN design to meet the requirements were investigated for the commercial and demonstration JSFR. In the commercial JSFR, a sampling type FFD which collects sodium from the reactor vessel by sampling lines for DN detectors was adopted. The performances have been investigated and confirmed by a fluid analysis in the reactor upper plenum. In the demonstration JSFR, the performance of DN detectors installed on the primary cold-leg piping has been confirmed. For the FFDL systems, experiences in the previous fast reactors and the R and D of FFDL system for JSFR were investigated. This study focuses on the Selector-Valve and the Tagging-Gas FFDL systems. Operation experiences of the Selector-valve FFDL system were accumulated in PFR and Phenix. Tagging-gas system experiences were accumulated in EBR-II and FFTF. The feasibility of both FFDL systems for JSFR was evaluated. (authors)

Aizawa, K.; Chikazawa, Y.; Ishikawa, N. [Japan Atomic Energy Agency JAEA, 4002 Narita, Oarai, Higashi-ibaraki-gun, Ibaraki 311-1393 (Japan); Kubo, S. [Japan Atomic Power Company JAPC (Japan); Okazaki, H.; Mito, M. [Mitsubishi FBR Systems, Inc. MFBR (Japan); Tozawa, K. [Fuji Electric Co., Ltd. (Japan); Hayashi, M. [MitsubishiElectric Corporation (Japan)

2012-07-01T23:59:59.000Z

208

Evaluation of the rainfall runoff conservation potential of two cross-diked furrow bed designs on the Texas High Plains  

E-Print Network [OSTI]

EVALUATION OF THE RAINr ALL RUNOFF CONSEPVATION POTENTIAL OF ~AO CROSS-DIKED FURROW BED DESIGNS ON THE TEXAS HIGH PLAINS A Thesis SCOTT ALI, EN SNI'ZH . Il c c tc, . a Gc "Huat= C ~ie( e Texas A&la Universicy in pazcial fuif ilirnent of he... requi=ements fo' the AS ER OF SCIENCE Ac 1 cD L1 01 Suh ject: Soi ' Science EVALUATION OF THE RAINFALL RUNOFF CONSERVATION POTENTIAL OF TWO CROSS-DIKED FURROW BED DESIGNS ON THE TEXAS HIGH PLAINS A Thesis by SCOTT ALLEN SHITH Approved as tc...

Smith, Scott Allen

1983-01-01T23:59:59.000Z

209

NREL Assesses National Design Standards for Offshore Wind (Fact Sheet)  

SciTech Connect (OSTI)

Report summarizes regulations, standards, and guidelines for the design and operation of offshore wind projects in the United States.

Not Available

2014-06-01T23:59:59.000Z

210

Design and development of a special purpose SAFT system for nondestructive evaluation of nuclear reactor vessels and piping components  

SciTech Connect (OSTI)

This report describes the design details of a special purpose system for real-time nondestructive evaluation of reactor vessels and piping components. The system consists of several components and the report presents the results of the research aimed at the design of each component and recommendations based on the results. One major component of the NDE system, namely the real-time SAFT processor, was designed with sufficient details to enable the fabrications of a prototype by GARD Inc. under a subcontract from The University of Michigan and the report includes their results and conclusions.

Ganapathy, S.; Schmult, B.; Wu, W.S.; Dennehy, T.G.; Moayeri, N.; Kelly, P.

1985-08-01T23:59:59.000Z

211

Interconnection Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Interconnection Guidelines Interconnection Guidelines Interconnection Guidelines < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Energy Sources Solar Wind Program Info State Delaware Program Type Interconnection Provider Delaware Public Service Commission '''''Note: Delaware law ([http://delcode.delaware.gov/title26/c010/index.shtml#1014 26 Del. C. § 1014]) requires the Delaware Public Service Commission (PSC), Delaware Electric Cooperative (DEC), and municipal utilities to develop interconnection rules using as a guide the Interstate Renewable Energy Council's (IREC) model interconnection rules and the U.S. Department of

212

Interconnection Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Interconnection Guidelines Interconnection Guidelines Interconnection Guidelines < Back Eligibility Commercial Industrial Residential Savings Category Bioenergy Commercial Heating & Cooling Manufacturing Buying & Making Electricity Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Wind Energy Sources Solar Program Info State Arizona Program Type Interconnection Provider Arizona Corporation Commission '''''Note: In June 2007, the Arizona Corporation Commission (ACC) initiated a rulemaking process to establish statewide interconnection standards for distributed generation (DG). This proceeding is still in progress. Until the new official rules go into effect, the commission has recommended that the utilities use the [http://images.edocket.azcc.gov/docketpdf/0000074361.pdf Interconnection

213

Interconnection Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Interconnection Guidelines Interconnection Guidelines Interconnection Guidelines < Back Eligibility Commercial Fed. Government Industrial Institutional Local Government Nonprofit Residential Schools State Government Savings Category Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Wind Program Info State Missouri Program Type Interconnection Provider Missouri Department of Natural Resources Missouri enacted legislation (S.B. 54) in June 2007 requiring all of the state's electric utilities -- including municipal utilities and electric cooperatives -- to offer net metering to customers with systems up to 100 kilowatts (kW) in capacity that generate electricity using wind energy, solar-thermal energy, hydroelectric energy, photovoltaics (PV), fuel cells

214

Interconnection Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Interconnection Guidelines Interconnection Guidelines Interconnection Guidelines < Back Eligibility Agricultural Commercial Industrial Residential Savings Category Bioenergy Buying & Making Electricity Solar Home Weatherization Water Wind Program Info State Nebraska Program Type Interconnection Provider Nebraska Energy Office Nebraska enacted legislation in May 2009 [http://nebraskalegislature.gov/FloorDocs/101/PDF/Final/LB436.pdf (LB 436)], establishing general rules for interconnecting and net metering systems that generate electricity. Nebraska's policy applies to systems that use solar, wind, methane, biomass, hydropower or geothermal resources to produce electricity and have a rated capacity of 25 kilowatts (kW) or less. To be eligible, a facility must meet all applicable safety, performance,

215

Recommendations to the NRC on human engineering guidelines for nuclear power plant maintainability  

SciTech Connect (OSTI)

This document contains human engineering guidelines which can enhance the maintainability of nuclear power plants. The guidelines have been derived from general human engineering design principles, criteria, and data. The guidelines may be applied to existing plants as well as to plants under construction. They apply to nuclear power plant systems, equipment and facilities, as well as to maintenance tools and equipment. The guidelines are grouped into seven categories: accessibility and workspace, physical environment, loads and forces, maintenance facilities, maintenance tools and equipment, operating equipment design, and information needs. Each chapter of the document details specific maintainability problems encountered at nuclear power plants, the safety impact of these problems, and the specific maintainability design guidelines whose application can serve to avoid these problems in new or existing plants.

Badalamente, R.V.; Fecht, B.A.; Blahnik, D.E.; Eklund, J.D.; Hartley, C.S.

1986-03-01T23:59:59.000Z

216

MBM fuel feeding system design and evaluation for FBG pilot plant  

SciTech Connect (OSTI)

Highlights: Black-Right-Pointing-Pointer A 1-5 g/s fuel feeding system for pilot scale FBG was designed, built and tested. Black-Right-Pointing-Pointer Multiple conveying stages improve pressure balancing, flow control and stability. Black-Right-Pointing-Pointer Secondary conveyor stage reduced output irregularity from 47% to 15%. Black-Right-Pointing-Pointer Pneumatic air sparging effective in dealing with poor flow ability of MBM powder. Black-Right-Pointing-Pointer Pneumatic injection port plugs with char at gasification temperature of 850 Degree-Sign C. - Abstract: A biomass fuel feeding system has been designed, constructed and evaluated for a fluidized bed gasifier (FBG) pilot plant at the University of Saskatchewan (Saskatoon, SK, Canada). The system was designed for meat and bone meal (MBM) to be injected into the gasifier at a mass flow-rate range of 1-5 g/s. The designed system consists of two stages of screw conveyors, including a metering stage which controlled the flow-rate of fuel, a rotary airlock and an injection conveyor stage, which delivered that fuel at a consistent rate to the FBG. The rotary airlock which was placed between these conveyors, proved unable to maintain a pressure seal, thus the entire conveying system was sealed and pressurized. A pneumatic injection nozzle was also fabricated, tested and fitted to the end of the injection conveyor for direct injection and dispersal into the fluidized bed. The 150 mm metering screw conveyor was shown to effectively control the mass output rate of the system, across a fuel output range of 1-25 g/s, while the addition of the 50 mm injection screw conveyor reduced the irregularity (error) of the system output rate from 47% to 15%. Although material plugging was found to be an issue in the inlet hopper to the injection conveyor, the addition of air sparging ports and a system to pulse air into those ports was found to successfully eliminate this issue. The addition of the pneumatic injection nozzle reduced the output irregularity further to 13%, with an air supply of 50 slpm as the minimum air supply to drive this injector. After commissioning of this final system to the FBG reactor, the injection nozzle was found to plug with char however, and was subsequently removed from the system. Final operation of the reactor continues satisfactorily with the two screw conveyors operating at matching pressure with the fluidized bed, with the output rate of the system estimated based on system characteristic equations, and confirmed by static weight measurements made before and after testing. The error rate by this method is reported to be approximately 10%, which is slightly better than the estimated error rate of 15% for the conveyor system. The reliability of this measurement prediction method relies upon the relative consistency of the physical properties of MBM with respect to its bulk density and feeding characteristics.

Campbell, William A., E-mail: bill.campbell@usask.ca [Fluidization Laboratory of Saskatchewan (FLASK) (Canada) and Department of Chemical and Biological Engineering, University of Saskatchewan (Canada); Fonstad, Terry [Department of Chemical and Biological Engineering, University of Saskatchewan (Canada); Pugsley, Todd [Suncor Energy Inc., Calgary, Alberta (Canada); Gerspacher, Regan [Fluidization Laboratory of Saskatchewan (FLASK) (Canada); Department of Chemical and Biological Engineering, University of Saskatchewan (Canada)

2012-06-15T23:59:59.000Z

217

Measure Guideline: Hybrid Foundation Insulation Retrofits  

SciTech Connect (OSTI)

This measure guideline provides recommendations for designs and variations for retrofit hybrid assemblies in improving interior foundation insulation and water management of basements. Variations include closed cell spray foam (ccSPF) with membrane waterproofing or air gap membrane drainage layers, rigid board foam insulation at flat walls (cast concrete or CMU block), a 'partial drainage' detail making use of the bulk water drainage that occurs through the field of a rubble stone wall, and non-drained spray foam assemblies (including slab insulation).

Ueno, K.; Lstiburek, J.

2012-05-01T23:59:59.000Z

218

American Recovery and Reinvestment Act General Guidelines for Emblem and Logo Applications  

Broader source: Energy.gov (indexed) [DOE]

// American Recovery and Reinvestment Act // General Guidelines for Emblem and Logo Applications Page 1 // American Recovery and Reinvestment Act // General Guidelines for Emblem and Logo Applications Page 1 American Recovery and Reinvestment Act General Guidelines for Emblem and Logo Applications Version 1.0 03 / 20 / 09 Projects funded by the American Recovery and Reinvestment Act (ARRA) will bear a newly-designed emblem. The emblem is a symbol of President Obama's commitment to the American People to invest their tax dollars wisely to put Americans back to work. The purpose of this document is to provide general guidelines and specifications for using the

219

Guidelines for Carcinogen Risk Assessment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

P-03/001F P-03/001F March 2005 Guidelines for Carcinogen Risk Assessment Risk Assessment Forum U.S. Environmental Protection Agency Washington, DC DISCLAIMER This document has been reviewed in accordance with U.S. Environmental Protection Agency policy and approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use. CONTENTS 1. INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.1. PURPOSE AND SCOPE OF THE GUIDELINES . . . . . . . . . . . . . . . . . . . . . . . . 1-1 1.2. ORGANIZATION AND APPLICATION OF THE GUIDELINES . . . . . . . . . . . 1-3 1.2.1. Organization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 1.2.2. Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-5 1.3. KEY FEATURES OF THE CANCER GUIDELINES .

220

The development and evaluation of alternative designs for the Texas Farm-To-Market route marker  

E-Print Network [OSTI]

alternative designs were tested on a sample of 70 motorists from the Bryan/College Station community. Four laboratory tests were used to assess the effectiveness of the FM route marker designs. These tests were the glance legibility test, filtered...

Fenno, David W

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Process design and evaluation of value-added chemicals production from biomass  

Science Journals Connector (OSTI)

Three different biodiesel production processes were simulated using the SuperPro Designer program. The process for producing biodiesel from soybean oil and methanol was designed using commercial chemical catal...

A. -Ra Go; Jae Wook Ko; Sang Jun Lee…

2012-10-01T23:59:59.000Z

222

FLINDERS UNIVERSITY Guidelines for Contractor Safety  

E-Print Network [OSTI]

FLINDERS UNIVERSITY Guidelines for Contractor Safety INTRODUCTION............................................................................................................3 PERMITS TO WORK.........................................................................................4 SAFETY SIGNS

223

Synthesis and Evaluation of CO2 Thickeners Designed with Molecular Modeling  

SciTech Connect (OSTI)

The objective of this research was to use molecular modeling techniques, coupled with our prior experimental results, to design, synthesize and evaluate inexpensive, non-fluorous carbon dioxide thickening agents. The first type of thickener that was considered was associating polymers. Typically, these thickeners are copolymers that contain a highly CO{sub 2}-philic monomer, and a small concentration of a CO{sub 2}-phobic associating monomer. Yale University was solely responsible for the synthesis of a second type of thickener; small, hydrogen bonding compounds. These molecules have a core that contains one or more hydrogen-bonding groups, such as urea or amide groups. Non-fluorous, CO{sub 2}-philic functional groups were attached to the hydrogen bonding core of the compound to impart CO{sub 2} stability and macromolecular stability to the linear 'stack' of these compounds. The third type of compound initially considered for this investigation was CO{sub 2}-soluble surfactants. These surfactants contain conventional ionic head groups and composed of CO{sub 2}-philic oligomers (short polymers) or small compounds (sugar acetates) previously identified by our research team. Mobility reduction could occur as these surfactant solutions contacted reservoir brine and formed mobility control foams in-situ. The vast majority of the work conducted in this study was devoted to the copolymeric thickeners and the small hydrogen-bonding thickeners; these thickeners were intended to dissolve completely in CO{sub 2} and increase the fluid viscosity. A small but important amount of work was done establishing the groundwork for CO{sub 2}-soluble surfactants that reduced mobility by generating foams in-situ as the CO{sub 2}+surfactant solution mixed with in-situ brine.

Robert Enick; Erick Beckman; J. Karl Johnson

2009-08-31T23:59:59.000Z

224

Evaluating alternatives for housing India's urban poor : design studies, model and application in Ahmedabad  

E-Print Network [OSTI]

The study evaluates the three alternatives identified by the (National) Planning Commission for housing the Urban Poor in India: Upgrading, site and services, and housing. The basis for evaluation is the relationship of ...

Palamadai, Rajagopalan M

1982-01-01T23:59:59.000Z

225

Leadership in Energy and Environmental Design (LEED) - A critical evaluation by LCA and recommendations for improvement  

E-Print Network [OSTI]

LEED): A critical evaluation by LCA and recommendations forimprovement. Int J LCA 12 (special issue 1) 46-57. LifeLEED) A critical evaluation by LCA and recommendations for

Humbert, Sebastien; Abeck, Heike; Bali, Nishil; Horvath, Arpad

2007-01-01T23:59:59.000Z

226

Design of the National Impact Evaluation for the DOE Weatherization Assistance Program  

SciTech Connect (OSTI)

The U.S. Department of Energy is undertaking a new national evaluation of its Weatherization Assistance Program. Following the evaluation plan developed by the Oak Ridge National Laboratory, four studies will be performed to evaluate the Program as it was implemented in PY 2006: an impact assessment, a process assessment, special technical studies, and a synthesis study. This paper describes how the evaluation's research questions were identified and discusses the plans for implementing the impact assessment and special technical studies.

Ternes, Mark P [ORNL; Schweitzer, Martin [ORNL; Schmoyer, Richard L [ORNL; Tonn, Bruce Edward [ORNL; Eisenberg, Joel Fred [ORNL

2007-01-01T23:59:59.000Z

227

Guidelines for makeup water treatment  

SciTech Connect (OSTI)

The EPRI Fossil Plant Cycle Chemistry Program, RP 2712, was developed in recognition of the importance of controlling cycle water and steam purity in attainment of maximized unit availability, reliability and efficiency. This guideline characterizes the state-of-the-art technology for production of cycle makeup water. It is intended to complement other RP 2712 projects in the areas of cycle chemistry guidelines, instrumentation and control, guideline demonstration and verification, and related subject areas. This guideline reviews available technology for and preferred approaches to production of fossil plant cycle makeup from various raw water supplies. Subject areas covered include makeup water source and source characteristics, unit processes comprising makeup treatment systems, guidelines for process selection, resin and membrane selection guidelines, techniques for monitoring performance and cost effectiveness, and waste disposal considerations. The report also identifies additional research activity needed to advance the state-of-the-art for makeup water treatment, results of a utility industry survey and other related topics. 72 refs., 60 figs., 74 tabs.

Cline, D.A. Jr.; Shields, K.J. (Powell (Sheppard T.) Associates, Baltimore, MD (USA))

1990-03-01T23:59:59.000Z

228

Sandia National Laboratory Photovoltaic Design Resources | Open Energy  

Open Energy Info (EERE)

Sandia National Laboratory Photovoltaic Design Resources Sandia National Laboratory Photovoltaic Design Resources Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Photovoltaic Design Resources at Sandia National Laboratories Agency/Company /Organization: Sandia National Laboratories Sector: Energy Focus Area: Renewable Energy, Solar Topics: Pathways analysis Website: www.sandia.gov/ References: Sandia's Photovoltaic Research and Development Program [1] Sandia National Laboratories' Photovoltaic Research and Development program works with industry and academia to accelerate development and acceptance of technologies for photovoltaic energy systems. The program has published a series of handbooks and booklets that describe design guidelines for stand-alone photovoltaic system installations, photovoltaic water pumping systems, and evaluating photvoltaic applications

229

Machine Shop Safety Tips & Safety Guidelines GENERAL SAFETY TIPS  

E-Print Network [OSTI]

Machine Shop Safety Tips & Safety Guidelines GENERAL SAFETY TIPS · Safety glasses with side shields distance away from moving machine parts, work pieces, and cutters. · Use hand tools for their designed to oil, clean, adjust, or repair any machine while it is running. Stop the machine and lock the power

Veiga, Pedro Manuel Barbosa

230

Design  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Design Design of a Multithreaded Barnes-Hut Algorithm for Multicore Clusters Technical Report Junchao Zhang and Babak Behzad Department of Computer Science, University of Illinois at Urbana-Champaign {jczhang, bbehza2}@illinois.edu Marc Snir Department of Computer Science, University of Illinois at Urbana-Champaign and MCS Division, Argonne National Laboratory snir@anl.gov Abstract We describe in this paper an implementation of the Barnes-Hut al- gorithm on multicore clusters. Based on a partitioned global ad- dress space (PGAS) library, the design integrates intranode mul- tithreading and internode one-sided communication, exemplifying a PGAS + X programming style. Within a node, the computation is decomposed into tasks (subtasks), and multitasking is used to hide network latency. We study the tradeoffs between locality in private caches and locality in shared caches

231

Evaluating direct energy savings and market transformation effects: A decade of technical design assistance in the northwestern USA  

Science Journals Connector (OSTI)

This paper documents the direct energy savings and energy efficiency market transformation impacts of a multi-state design assistance program in the northwestern US. The paper addresses four specific aims. (1) It provides a conservative and justified estimate of the direct energy savings associated with design assistance activities of a market transformation program from 2001 to 2010. (2) It provides a rigorous methodology to evaluate direct energy savings associated with design assistance market transformation programs. (3) It provides a low-cost replicable method to predict energy savings in new buildings by evaluating the integrated design process. (4) It provides quantitative indicators useful for estimating indirect energy savings from market transformation. Applying the recommended analysis method and assuming a 12-year measure life, the direct energy savings of the population (626 buildings; 51,262,000 ft2) is estimated as 45.3 aMW (average megawatts) (electric), and 265,738.089 therms (non-electric). If the entire program budget were divided into the electric savings only, the Lab Network cost per kWh saved ranged from $0.0016 to $0.003 using the recommended method and $0.0092/kWh using the most conservative method. These figures do not isolate contextual influences or represent total resource cost. Statistically significant correlations (r2=0.1?0.3) between integrated design scores and energy savings are reported.

Kevin Van Den Wymelenberg; G.Z. Brown; Heather Burpee; Ery Djunaedy; Gunnar Gladics; Jeff Kline; Joel Loveland; Christopher Meek; Harshana Thimmanna

2013-01-01T23:59:59.000Z

232

Human Factors design and evaluation criteria applied to academic and instructional websites.  

E-Print Network [OSTI]

??This culminating project applies Human Factors principles to the analysis of various web designs. This culminating project consists of three major parts. The first chapter… (more)

Mendez, Veronica

2015-01-01T23:59:59.000Z

233

Development and Application of Advanced Models for Steam Hydrogasification: Process Design and Economic Evaluation  

E-Print Network [OSTI]

design, modeling and process economic analysis are employedper day. Like BTL process, economic analysis has shown thatused as major input for process economic analysis in the

Lu, Xiaoming

2012-01-01T23:59:59.000Z

234

Critical Simulation Based Evaluation of Thermally Activated Building Systems (TABS) Design Models  

E-Print Network [OSTI]

design and control of water supply temperature has beenfeedback control of water supply temperature in addition to2012 Control Requires preliminary water supply temperature

Basu, Chandrayee

2012-01-01T23:59:59.000Z

235

Developing Guidelines for Assessing Visual Analytics Environments  

SciTech Connect (OSTI)

Visual analytic systems can be evaluated from a user perspective with quantitative metrics (i.e., time to complete the analysis or the accuracy of the solution found). However, qualitative measures are also useful in a user assessment. These include such measures as the utility of the interactive visualizations in the analysis process and the user's assessment of the efficiency of the analytic process. Quantitative measures can be found if data sets with embedded ground truth are used for analysis. Qualitative measures are more elusive. In this paper we report on an experiment with professional analysts who ranked five of submissions to the VAST 2009 Challenge and provided the rationale for their rankings. Their comments were used in conjunction with a meta-analysis of the 2009 VAST Challenge reviews to produce a set of guidelines for visual analytic systems. As visual analytic software is expected to eventually help in all aspects of analysis, we expect to see future systems provide more help with generating the final report. Hence, researchers also need to have an understanding of what makes a good analytic product. Therefore we asked the analysts to rank the situational assessments of four grand challenge entries and to provide comments on those assessments. We used these comments to produce guidelines for researchers to use in evaluating their analytic reports.

Scholtz, Jean

2011-09-22T23:59:59.000Z

236

UTS Design Guidelines P-PO.01.13 UTS DESIGN GUIDELINES  

E-Print Network [OSTI]

of LONG LIFE/LOW ENERGY/LOW MAINTENANCE/LOOSE FIT. Buildings and fit-outs should not be extravagant property portfolio. Decisions to refurbish, extend or construct new buildings pose unique challenges of producing this document. In particular, the assistance of the following parties is acknowledged: · Griffith

University of Technology, Sydney

237

Engineering safety evaluation for 22 ton steel disposal box lifting bail design  

SciTech Connect (OSTI)

The objective of this analysis is to design and analyze the lifting bail of the 22 Ton Steel Waste Disposal Box (SWDB). The new design takes the original lifting bail and adds a hinge allowing the top portion of the bail to fold over towards the lid.

BOEHNKE, W.M.

1999-11-23T23:59:59.000Z

238

Software openness: evaluating parameters of parametric modeling tools to support creativity and multidisciplinary design integration  

Science Journals Connector (OSTI)

The ubiquitous computing era has pushed the Architecture, Engineering, and Construction (AEC) industry towards new frontiers of digitally enabled practice. Are these the frontiers originally identified by the pioneers in the field? Architectural design ... Keywords: CAD, CAE, parametric design, parametric modeling, software openness

Flora Dilys Salim; Jane Burry

2010-03-01T23:59:59.000Z

239

Usability evaluation of designed image code interface for mobile computing environment  

Science Journals Connector (OSTI)

Recently, image code interfaces and designed image codes, which can present visual information such as shapes, colors, text, images, and textures within the image code, have attracted increasing interest for use in mobile computing environments. In this ... Keywords: 2D code, barcode, color-based image code, designed code, image code

Cheolho Cheong; Dong-Chul Kim; Tack-Don Han

2007-07-01T23:59:59.000Z

240

Discrete-event simulation for the design and evaluation of physical protection systems  

SciTech Connect (OSTI)

This paper explores the use of discrete-event simulation for the design and control of physical protection systems for fixed-site facilities housing items of significant value. It begins by discussing several modeling and simulation activities currently performed in designing and analyzing these protection systems and then discusses capabilities that design/analysis tools should have. The remainder of the article then discusses in detail how some of these new capabilities have been implemented in software to achieve a prototype design and analysis tool. The simulation software technology provides a communications mechanism between a running simulation and one or more external programs. In the prototype security analysis tool, these capabilities are used to facilitate human-in-the-loop interaction and to support a real-time connection to a virtual reality (VR) model of the facility being analyzed. This simulation tool can be used for both training (in real-time mode) and facility analysis and design (in fast mode).

Jordan, S.E.; Snell, M.K.; Madsen, M.M. [Sandia National Labs., Albuquerque, NM (United States); Smith, J.S.; Peters, B.A. [Texas A and M Univ., College Station, TX (United States). Industrial Engineering Dept.

1998-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Guidelines and Toolkits for Urban Transport Development in Medium Sized  

Open Energy Info (EERE)

Guidelines and Toolkits for Urban Transport Development in Medium Sized Guidelines and Toolkits for Urban Transport Development in Medium Sized Cities in India Jump to: navigation, search Tool Summary Name: Guidelines and Toolkits for Urban Transport Development in Medium Sized Cities in India Agency/Company /Organization: Asian Development Bank Focus Area: Governance - Planning - Decision-Making Structure Topics: Best Practices Complexity/Ease of Use: Not Available Website: sti-india-uttoolkit.adb.org/ Transport Toolkit Region(s): Asia Related Tools Promoting Clean Cars: Case Study of Stockholm and Sweden MOtor Vehicle Emission Simulator (MOVES) The World Bank - Transport ... further results Find Another Tool FIND TRANSPORTATION TOOLS This resource is designed to help decision makers and practitioners in states and municipal governments who are concerned with urban transport

242

Guidelines for Participating in the DOE Challenge Home | Department of  

Broader source: Energy.gov (indexed) [DOE]

Residential Buildings » Challenge Home » Guidelines for Residential Buildings » Challenge Home » Guidelines for Participating in the DOE Challenge Home Guidelines for Participating in the DOE Challenge Home The DOE Challenge Home is a new and compelling way to recognize builders for their leadership in increasing energy efficiency, improving indoor air quality, and making homes zero net-energy ready. The program builds upon the comprehensive building science requirements of ENERGY STAR® for Homes Version 3, along with proven Building America innovations and best practices. Other special attribute programs are incorporated to help builders reach unparalleled levels of performance with homes designed to last hundreds of years. DOE Challenge Homes are verified by a qualified third-party and are at least 40%-50% more energy efficient than a typical new home. This generally

243

2014 Research & Study Abroad Program in Panama Recommendation Form and Guidelines  

E-Print Network [OSTI]

2014 Research & Study Abroad Program in Panama Recommendation Form. ================================================================ Evaluator Guidelines The Panama Research and Study Abroad program of Panama working with researchers of the Water Center for the Humid Tropics

Alabama in Huntsville, University of

244

ARM - Baseline Change Request Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

DocumentsBaseline Change Request Guidelines DocumentsBaseline Change Request Guidelines Page Contents Introduction Submit a BCR BCR Process Flowchart Baseline Change Request Guidelines Introduction Baseline Change Requests (BCR) are used by the ARM Infrastructure as a process to provide configuration control and for formally requesting and documenting changes within the ARM Infrastructure. Configuration Control: BCRs are required for changes to instruments, data systems, data processes, datastreams, measurement methods, and facilities. They help ensure that all aspects of the ARM Infrastructure are consulted prior to implementing changes. Seemingly minor changes can have significant repercussions throughout the Facility and therefore, NO change to an operational instrument, computer, facility, or other system can or will be

245

An integrated workstation environment for design and evaluation of analog integrated circuits  

E-Print Network [OSTI]

, TABLE OF CONTENTS CHAPTER Page I INTRODUCTION A. B. C. D. E. F. G. H. Design aspects Scope of this thesis Analog design procedures Hierarchical design Behavioral simulation Using mathematical models for simulation Conclusion... Deliverables 1 1 2 3 5 5 8 9 II COMPONENTS OF THE SYSTEM 10 A. B. C. D. E. F. G. H. Introduction Hardware overview The HP 9000/310 workstation The HP 9000/318 workstations Addition of an HP 9000/332 Possible addition of a more powerful...

Soenen, Eric Georges

2012-06-07T23:59:59.000Z

246

Guidelines for Provision and Interchange of Geothermal Data Assets...  

Energy Savers [EERE]

Guidelines for Provision and Interchange of Geothermal Data Assets Guidelines for Provision and Interchange of Geothermal Data Assets This document presents guidelines related to...

247

Design and evaluation of a cantilever beam-type prosthetic foot for Indian persons with amputations  

E-Print Network [OSTI]

The goal of this work is to design a low cost, high performance prosthetic foot in collaboration with Bhagwan Mahaveer Viklang Sahayata Samiti (BMVSS), in Jaipur, India. In order to be adopted, the foot must cost less than ...

Olesnavage, Kathryn M

2014-01-01T23:59:59.000Z

248

Projection of fractures in ships for the evaluation of fatigue resistant designs  

E-Print Network [OSTI]

Cracks in ships have been of great concern to the maritime industry for a very long time. The problem is controlled by improving design, minimizing operating stresses and through regular inspections and repairs. The big ...

Hadjiyiannis, Nicholas

2009-01-01T23:59:59.000Z

249

Design, optimization and evaluation of a free-fall biomass fast pyrolysis reactor and its products.  

E-Print Network [OSTI]

??The focus of this work is a radiatively heated, free-fall, fast pyrolysis reactor. The reactor was designed and constructed for the production of bio-oil from… (more)

Ellens, Cody James

2009-01-01T23:59:59.000Z

250

The evolution and evaluation of an interactive engineering design teaching tool : MIT's EDICS  

E-Print Network [OSTI]

For this thesis, I refined and tested a computer-based engineering teaching tool called EDICS. EDICS (Engineering Design Instructional Computer Program) has proven to be a fun and intriguing means of conveying a wide variety ...

Jimenez, Craig Edward

2006-01-01T23:59:59.000Z

251

Design, construction and evaluation of a facility for the simulation of fast reactor blankets  

E-Print Network [OSTI]

A facility has been designed and constructed at the MIT Reactor for the experimental investigation of typical LMFBR breeding blankets. A large converter assembly, consisting of a 20-cm-thick layer of graphite followed by ...

Forbes, Ian Alexander

1970-01-01T23:59:59.000Z

252

Global precipitation retrieval algorithm trained for SSMIS using a numerical weather prediction model: Design and evaluation  

E-Print Network [OSTI]

This paper presents and evaluates a global precipitation retrieval algorithm for the Special Sensor Microwave Imager/Sounder (SSMIS). It is based on those developed earlier for the Advanced Microwave Sounding Unit (AMSU) ...

Surussavadee, Chinnawat

253

Evaluation and Design of Utility Co-Owned Cogeneration Systems for Industrial Parks  

E-Print Network [OSTI]

The Electric Power Research Institute, EPRI, is currently evaluating the potential of utility co-owned cogeneration facilities in industrial parks. This paper describes part of the work performed by one of EPRI's contractors, Impell Corporation...

Hu, D. S.; Tamaro, R. F.; Schiller, S. R.

1984-01-01T23:59:59.000Z

254

Transfer passenger needs at airports : human factors in terminal design  

E-Print Network [OSTI]

This thesis analyzes the needs of particular users of airport: transfer passengers. The object of this work has been to produce a set of design guidelines for terminals. these guidelines are framed upon a user-need survey ...

Brillembourg, Marie-Claire

1982-01-01T23:59:59.000Z

255

Deep Borehole Disposal Research: Demonstration Site Selection Guidelines,  

Broader source: Energy.gov (indexed) [DOE]

Deep Borehole Disposal Research: Demonstration Site Selection Deep Borehole Disposal Research: Demonstration Site Selection Guidelines, Borehole Seals Design, and RD&D Needs Deep Borehole Disposal Research: Demonstration Site Selection Guidelines, Borehole Seals Design, and RD&D Needs The U.S. Department of Energy has been investigating deep borehole disposal as one alternative for the disposal of spent nuclear fuel and other radioactive waste forms, along with research and development for mined repositories in salt, granite, and clay, as part of the used fuel disposition (UFD) campaign. The deep borehole disposal concept consists of drilling a borehole on the order of 5,000 m deep, emplacing waste canisters in the lower part of the borehole, and sealing the upper part of the borehole with bentonite and concrete seals. A reference design of the

256

Job Counting Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Mission » Recovery Act » Job Counting Guidelines Mission » Recovery Act » Job Counting Guidelines Job Counting Guidelines The following updated definitions and guidelines are intended to provide EM Recovery Act sites with information to collect and report timely and accurate full-time equivalent and cumulative head-count data for both monthly and quarterly jobs data calls. These revised guidelines supersede the previous monthly jobs data reporting definitions and guidelines dated February 9, 2010. These revised guidelines remain consistent with OMB guidance issued December 18, 2009 and cover subcontractors and vendors as well as prime contractors. Job Counting Guidelines More Documents & Publications EA-1548: Finding of No Significant Impact Microsoft Word - Horizon Wind Energy Comments.docx Proceedings of the Computational Needs for the Next Generation Electric

257

Recordkeeping for Offshore Course Offerings Guideline  

E-Print Network [OSTI]

Guideline Recordkeeping for Offshore Course Offerings Guideline Policy Supported: Recordkeeping and operation of Offshore Courses. Contact Officer: Manager, Records Management Phone: 9360 2162 Printed copies outlines responsibilities for managing records in all formats associated with Offshore Courses

258

Pilot Implementation of a Field Study Design to Evaluate the Impact of Source Control Measures on Indoor Air Quality in High Performance Homes  

SciTech Connect (OSTI)

To improve the indoor air quality in new, high performance homes, a variety of standards and rating programs have been introduced to identify building materials that are designed to have lower emission rates of key contaminants of concern and a number of building materials are being introduced that are certified to these standards. For example, the U.S. Department of Energy (DOE) Zero Energy Ready Home program requires certification under the U.S. Environmental Protection Agency (EPA) Indoor airPLUS (IaP) label, which requires the use of PS1 or PS2 certified plywood and OSB; low-formaldehyde emitting wood products; low- or no-VOC paints and coatings as certified by Green Seal Standard GS-11, GreenGuard, SCS Indoor Advantage Gold Standard, MPI Green Performance Standard, or another third party rating program; and Green Label-certified carpet and carpet cushions. However, little is known regarding the efficacy of the IAP requirements in measurably reducing contaminant exposures in homes. The goal of this project is to develop a robust experimental approach and collect preliminary data to support the evaluation of indoor air quality (IAQ) measures linked to IAP-approved low-emitting materials and finishes in new residential homes. To this end, the research team of Pacific Northwest National Laboratory (PNNL) and Lawrence Berkeley National Laboratory (LBNL) developed a detailed experimental plan to measure IAQ constituents and other parameters, over time, in new homes constructed with materials compliant with IAP’s low-emitting material and ventilation requirements (i.e., section 6.1, 6.2, 6.3, and 7.2) and similar homes constructed to the state building code with conventional materials. The IAQ in IAP and conventional homes of similar age, location, and construction style is quantified as the differences in the speciated VOC and aldehyde concentrations, normalized to dilution rates. The experimental plan consists of methods to evaluate the difference between low-emitting and “conventional” materials as installed in newly constructed residential homes using both (1) highly controlled, short-term active samples to precisely characterize the building-related chemical emissions and building contents and (2) a week-long passive sample designed to capture the impact of occupant behavior and related activities on measured IAQ contaminant levels indoors. The combination of detailed short-term measurements with the home under controlled/consistent conditions during pre- and post-occupancy and the week-long passive sampling data provide the opportunity to begin to separate the different emission sources and help isolate and quantify variability in the monitored homes. Between April and August 2014, the research team performed pre-occupancy and post-occupancy sampling in one conventional home and two homes built with low-emitting materials that were generally consistent with EPA’s Indoor airPLUS guidelines. However, for a number of reasons, the full experimental plan was not implemented. The project was intended to continue for up to three years to asses long-term changes in IAQ but the project was limited to one calendar year. As a result, several of the primary research questions related to seasonal impacts and the long-term trends in IAQ could not be addressed. In addition, there were several unexpected issues related to recruiting, availability of home types, and difficulty coordinating with builders/realtors/homeowners. Several field monitoring issues also came up that provide “lessons learned” that led to improvements to the original monitoring plan. The project produced a good experimental plan that is expected to be be useful for future efforts collecting data to support answering these same or similar research questions.

Widder, Sarah H.; Chamness, Michele A.; Petersen, Joseph M.; Singer, Brett C.; Maddalena, Randy L.; Destaillats, Hugo

2014-10-20T23:59:59.000Z

259

EMERGENCY HIRE GUIDELINES HUMAN RESOURCES  

E-Print Network [OSTI]

EMERGENCY HIRE GUIDELINES HUMAN RESOURCES Workforce Planning · One Washington Square · San José, Ca: Workforce Planning; Sr. Workforce Planning Analyst DATE: May 2, 2008 I. PURPOSE / DESCRIPTION The Emergency. B. The Workforce Planning Analyst will work with the hiring manager/HR contact to identify and hire

Su, Xiao

260

Physics 432 532 Project Guidelines  

E-Print Network [OSTI]

Physics 432 532 Project Guidelines The primary goals are to choose a project which you nd fun you will need to demonstrate the working circuit if indeed it does work!, what are its problems referencesinclude: Radio Electronics" and Popular Electronics". The radio Amateur's Handbook might be useful. You

Frey, Raymond E.

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Biomedical Sciences Graduate Program Guidelines  

E-Print Network [OSTI]

Biomedical Sciences Graduate Program Guidelines 1111 West 17th Street Tulsa, OK 74107-1898 #12;2 Table of Contents Section Page Number Program Description 3 1. Master of Science (M.S.) in Biomedical (Ph.D.) in Biomedical Sciences 7 3.1 Ph.D. Degree Program Requirements 7-10 4. Doctor of Osteopathic

Veiga, Pedro Manuel Barbosa

262

A method of evaluating Sulphlex mix designs based on the indirect tension test  

E-Print Network [OSTI]

approach to characteriz1ng fatigue life. A procedure for optimizing a mix design was outlined. Design charts for permanent deformation, thermal cracking and fat1gue cracking were presented for Sulphiex binders CR-1 and CR-2 and an asphalt cement (AC-10... of fracture temperature of an asphalt concrete [from Hills and Brien (16)]. . . . . . . 34 22 Failure envelopes for AC-10 crushed limestone mixes of 4 and 7 percent binder content . 37 23 Prediction of thermal cracking using the boundary curve. 39 24...

Richey, Barry Lee

1982-01-01T23:59:59.000Z

263

EPA`s risk assessment guidelines: Overview  

SciTech Connect (OSTI)

The US Environmental Protection Agency (EPA) risk assessment guidelines for cancer, quantification, and exposure issues are discussed.

Patton, D.E. [Environmental Protection Agency, Washington, DC (United States)

1990-12-31T23:59:59.000Z

264

Operational Guidelines/Radiological Emergency Response  

Broader source: Energy.gov [DOE]

Operational Guidelines/Radiological Emergency Response. Provides information and resources concerning the development of Operational Guidelines as part of planning guidance for protection and recovery following Radiological Dispersal Device (RDD) and/or Improvised Nuclear Device (IND) incidents. Operational Guidelines Technical (OGT) Manual, 2009 RESRAD-RDD Complementing Software to OGT Manual EPA Protective Action Guidelines (2013), Interim Final Federal Radiological Monitoring and Assessment Center (FRMAC) Federal Radiological Preparedness Coordinating Committee (FRPCC)

265

Derivation of residual radioactive material guidelines for uranium in soil at the Middlesex Sampling Plant Site, Middlesex, New Jersey  

SciTech Connect (OSTI)

Residual radioactive material guidelines for uranium in soil were derived for the Middlesex Sampling Plant (MSP) site in Middlesex, New Jersey. This site has been designated for remedial action under the Formerly Utilized Sites Remedial Action Program (FUSRAP) of the US Department of Energy. The site became contaminated from operations conducted in support of the Manhattan Engineer District (MED) and the Atomic Energy Commission (AEC) between 1943 and 1967. Activities conducted at the site included sampling, storage, and shipment of uranium, thorium, and beryllium ores and residues. Uranium guidelines for single radioisotopes and total uranium were derived on the basis of the requirement that the 50-year committed effective dose equivalent to a hypothetical individual living or working in the immediate vicinity of the MSP site should not exceed a dose of 30 mrem/yr following remedial action for the current-use and likely future-use scenarios or a dose of 100 mrem/yr for less likely future-use scenarios. The RESRAD computer code, which implements the methodology described in the DOE manual for establishing residual radioactive material guidelines, was used in this evaluation. Four scenarios were considered for the site. These scenarios vary regarding future land use at the site, sources of water used, and sources of food consumed.

Dunning, D.E. [Argonne National Lab., IL (United States). Environmental Assessment Div.

1995-02-01T23:59:59.000Z

266

Metrics for Evaluating Service Designs Based on SoaML Michael Gebhart, Sebastian Abeck  

E-Print Network [OSTI]

| abeck} @kit.edu Abstract--In the context of service-oriented architectures, quality attributes and service designs based on the Service oriented architecture Modeling Language as standardized language for modeling service-oriented architectures. To illustrate the metrics and to verify their validity, service

Abeck, Sebastian

267

Evaluation of critical materials in five additional advance design photovoltaic cells  

SciTech Connect (OSTI)

The objective of this study is to identify potential material supply constraints due to the large-scale deployment of five advanced photovoltaic (PV) cell designs, and to suggest strategies to reduce the impacts of these production capacity limitations and potential future material shortages. The Critical Materials Assessment Program (CMAP) screens the designs and their supply chains and identifies potential shortages which might preclude large-scale use of the technologies. The results of the screening of five advanced PV cell designs are presented: (1) indium phosphide/cadmium sulfide, (2) zinc phosphide, (3) cadmium telluride/cadmium sulfide, (4) copper indium selenium, and (5) cadmium selenide photoelectrochemical. Each of these five cells is screened individually assuming that they first come online in 1991, and that 25 Gwe of peak capacity is online by the year 2000. A second computer screening assumes that each cell first comes online in 1991 and that each cell has a 5 GWe of peak capacity by the year 2000, so that the total online capacity for the five cells is 25 GWe. Based on a review of the preliminary baseline screening results, suggestions were made for varying such parameters as the layer thickness, cell production processes, etc. The resulting PV cell characterizations were then screened again by the CMAP computer code. The CMAP methodology used to identify critical materials is described; and detailed characterizations of the advanced photovoltaic cell designs under investigation, descriptions of additional cell production processes, and the results are presented. (WHK)

Smith, S.A.; Watts, R.L.; Martin, P.; Gurwell, W.E.

1981-02-01T23:59:59.000Z

268

Design and Evaluation of a High Temperature Burner Duct Recuperator System  

E-Print Network [OSTI]

"The Babcock & Wilcox Company (B&W) has completed a program to design, construct, install, and field test a ceramic-based high-temperature burner-duct-recuperator (HTBDR) in an industrial setting. The unit was capable of operating in corrosive, high...

Parks, W. P.; DeBellis, C. L.; Kneidel, K.

269

Evaluating eXtreme Scenario-based Design in a Distributed Agile Team  

E-Print Network [OSTI]

Virginia Tech Blacksburg VA 24061-0106 mccricks@cs.vt.edu #12;Introduction Agile software development exploring ways to integrate usability into agile software development methodologies. However, they do with Meridium, Inc. to look at how eXtreme Scenario-based Design (XSBD), an agile usability approach developed

270

Evaluation of Insulation Systems for the Optimal Design of High Voltage Pulse Transformers  

E-Print Network [OSTI]

This paper presents a study for the design of the insulation systems of high voltage pulse transformer based on experimental tests and numerical simulations. Data of high voltage tests on solid and liquid insulation materials are presented and discussed. The understanding of each part of the insulation is supported by electrostatic fields simulations.

Sylvain, Candolfi; Davide, Aguglia; Philippe, Viarouge; Jürgen, Biela; Jerome, Cros

2015-01-01T23:59:59.000Z

271

Ethics Guidelines for Environmental Epidemiologists Introduction  

E-Print Network [OSTI]

Ethics Guidelines for Environmental Epidemiologists Introduction "Towards Ethics Guidelines Environment, Vol. 184(1996):137-147. This paper includes the ethics guidelines adopted by the ISEE in 1999 as the Society's official statement on ethical conduct for environmental epidemiologists. Elsevier has kindly

Biederman, Irving

272

M&V Guidelines: Measurement and  

E-Print Network [OSTI]

M&V Guidelines: Measurement and Verification for Federal Energy Projects Version 3.0 #12;M&V Guidelines: Measurement and Verification for Federal Energy Projects Version 3.0 Prepared For: U 2007. M&V Guidelines 3.0 FEMPii #12;Contents Section Page Section 1 Measurement and Verification (M

273

TESTING AND EVALUATION OF THE MODIFIED DESIGN OF THE 25-DISK ROTARY MICROFILTER  

SciTech Connect (OSTI)

This report details redesign of a commercially available rotary microfilter to meet the operational and maintenance requirements for radioactive service. Personnel developed the design and coordinated procurement of two filters followed by testing of one unit. System testing examined the ability to rinse soluble material from the system, filtration performance using several insoluble solids loadings, effectiveness in washing sludge, amount of wear to parts and maintenance of the system including the insertion and removal of the filter stack, and the ability to flush solids from the system. The test program examined flushing the filter for soluble material by filling the system with a Rhodamine WT dye solution. Results showed that draining the system and rinsing with 50 gallons of water resulted in grater than 100X reduction of the dye concentration. Personnel determined filter performance using various amounts of insoluble sludge solids ranging from 0.06 to 15 weight percent (wt%) insoluble solids in a 3 molar (M) sodium simulated supernate. Through approximately 120 hours of start-and-stop (i.e., day shift) operation and various insoluble solids loadings, the filter produced filtration rates between 3 and 7 gallons per minute (gpm) (0.12-0.29 gpm/ft{sup 2}) for a 25-disk filter. Personnel washed approximately 80 gallons of simulated sludge using 207 gallons of inhibited water. Washing occurred at constant volume with wash water fed to a well mixed tank at the same rate as filtrate removal. Performance measurement involved collecting and analyzing samples throughout the washing for density and sodium content. Results showed an effective washing, mimicking a predicted dilution calculation for a well mixed tank and reducing the sodium concentration from 3.2 M to less than 0.3 M. Filtration rates during the washing process ranged between 3 and 4.3 gpm for one filter unit. The filter system then concentrated the washed 15 wt% insoluble solids slurry to approximately 20 wt% insoluble solids with no operational problems with the exception of the entrainment of air due to leaking packing in the feed pump. Prior to the air entrainment, the filtration rate was approximately 4.2 gpm for one filter assembly with the process fluid temperature adjusted to 35 C. Personnel measured the turbidity of filtrate samples from all phases of testing. All samples measured were less than 3 NTU, with the majority of samples less than 1 NTU. Thus, all measurements fell below the process acceptance criterion of less than 5 NTU. After slurry operations, personnel rinsed the filter with the equivalent of 250 gallons of water by re-circulating 50 gallons of water. The residual sludge solids remaining on the filter stack weighed approximately 685 grams. This amount of solids corresponds to an equivalent activity of 15.1 curies (Ci) beta and 0.38 Ci gamma radiation dose for Sludge Batch 4. Workers completely disassembled the filter system and examined it for signs of wear and component operation. An evaluation by a John Crane Inc. representative concluded that the wear observed on the mechanical seal resulted primarily from the numerous stops and starts, the abrasive nature of the process fluid and the possibility that the seal faces did not receive enough lubrication from the process fluid. No measurable slurry bypassed the mechanical seal. While it is extremely difficult to predict the life of the seal, the vendor representative indicates a minimum of one year in present service is reasonable. Changing the seal face material from silicon-carbide to a graphite-impregnated silicon-carbide is expected to double the life of the seal. Replacement with an air seal might be expected to increase lifetime to five years. The bottom bushing showed wear due to a misalignment during the manufacture of the filter tank. Minor adjustments to the alignment with shims and replacement of the graphite bushing with a superior material will greatly reduce this wear pattern.

Herman, D; Michael Poirier, M; Samuel Fink, S

2006-09-29T23:59:59.000Z

274

Status of NRC approval of EPRI electromagnetic interference susceptibility testing guidelines for digital equipment  

SciTech Connect (OSTI)

Historically, nuclear power plants installing digital equipment have been required to conduct expensive, site-specific electromagnetic interference (EMI) surveys to demonstrate that EMI will not affect the operation of sensitive electronic equipment. Consequently, EPRI formed a Utility Working Group which developed a set of generic EMI susceptibility testing guidelines, which were published as an EPRI report in September 1994. These guidelines are based upon EMI survey data obtained from several different plants and include criteria for determining their applicability. The Working Group interacted with NRC staff to obtain NRC approval. In April 1996, the NRC issued a Safety Evaluation Report (SER) endorsing the guidelines as a valid means of demonstrating EMI compatibility. The issuance of this SER was conditional on issuing a revision to the EPRI EMI Guidelines. This paper summarizes the guidelines, the NRC SER, and the current status of Revision 1 to the report.

James, R.W. [Electric Power Research Institute, Palo Alto, CA (United States); Shank, J.W. [Public Service Electric & Gas Company, Hancock`s Bridge, NJ (United States); Yoder, C. [Baltimore Gas & Electric, Lusby, MD (United States)

1996-12-31T23:59:59.000Z

275

An evaluation of alternative horizontal curve design approaches for rural two-lane highways  

E-Print Network [OSTI]

proposed by Lamm, et al, are: 1) Good: AD s 5' or 2) Fair: 3) Poor: AV? s 9. 7 km/h (6 mi/h), 5 '& PJ'S s 10' or 9. 7 km/h (6 mi/h) + A V? ~ 19. 3 kin/h (12 mi/h), and AO&10' or BV? + 19. 3 km/h (12 nn/h) (18). Foreign Horizontal Curve Design... at the 85th percentile speed. Maximum side friction values for design speeds higher than 90 km/h (55. 9 mi/h) are more than those side fiiction values used by vehicles operating at the 85th percentile speed, due to the concerns of comfort and safety...

Voigt, Anthony Paul

2012-06-07T23:59:59.000Z

276

2005 Adjudicative Guidelines Implementation | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

05 Adjudicative Guidelines Implementation 05 Adjudicative Guidelines Implementation 2005 Adjudicative Guidelines Implementation On December 29,2005, the President approved a revision of the Adjudicative Guidelines for Determining Eligibility for Access to Classified Information. The revised guidelines were distributed as an attachment to a memorandum from Stephen J. Hadley, Assistant to the President for National Security Affairs, addressed to William Leonard, Director of the Information Security Oversight Office. In his memorandum, Mr. Hadley instructed Mr. Leonard to circulate the revised guidelines for immediate implementation by all agencies that grant security clearances. Mr. Hadley further emphasized that all agencies must honor clearances granted under the new guidelines, consistent with Executive Order (E.O.) 12968 and the December 12,2005,

277

Design, manufacture, and evaluation of an anthropomorphic pelvic phantom purpose-built for radiotherapy dosimetric intercomparison  

SciTech Connect (OSTI)

Purpose: An anthropomorphic pelvic phantom was designed and constructed to meet specific criteria for multicenter radiotherapy dosimetric intercomparison. Methods: Three dimensional external and organ outlines were generated from a computed tomography image set of a male pelvis, forming the basis of design for an anatomically realistic phantom. Clinically relevant points of interest were selected throughout the dataset where point-dose values could be measured with thermoluminescence dosimeters and a small-volume ionization chamber. Following testing, three materials were selected and the phantom was manufactured using modern prototyping techniques into five separate coronal slices. Time lines and resource requirements for the phantom design and manufacture were recorded. The ability of the phantom to mimic the entire treatment chain was tested. Results: The phantom CT images indicated that organ densities and geometries were comparable to those of the original patient. The phantom proved simple to load for dosimetry and rapid to assemble. Due to heat release during manufacture, small air gaps and density heterogeneities were present throughout the phantom. The overall cost for production of the prototype phantom was comparable to other commercial anthropomorphic phantoms. The phantom was shown to be suitable for use as a ''patient'' to mimic the entire treatment chain for typical external beam radiotherapy for prostate and rectal cancer. Conclusions: The phantom constructed for the present study incorporates all characteristics necessary for accurate Level III intercomparison studies. Following use in an extensive Level III dosimetric comparison over a large time scale and geographic area, the phantom retained mechanical stability and did not show signs of radiation-induced degradation.

Harrison, K. M.; Ebert, M. A.; Kron, T.; Howlett, S. J.; Cornes, D.; Hamilton, C. S.; Denham, J. W. [Department of Radiation Oncology, Calvary Mater Newcastle, Waratah, New South Wales 2298, Australia and School of Physics, University of Newcastle, New South Wales 2308 (Australia); Department of Radiation Oncology, Sir Charles Gairdner Hospital, Western Australia, Australia and School of Physics, University of Western Australia, Western Australia 6009 (Australia); Department of Physical Sciences, Peter MacCallum Cancer Centre, Victoria 8006 (Australia); Australiasian College of Physical Scientists and Engineers in Medicine, Sydney, New South Wales 2020 (Australia); Trans-Tasman Radiation Oncology Group, Calvary Mater Newcastle, New South Wales 2298 (Australia); Heidelberg Repatriation Hospital, Victoria 3081 (Australia); Department of Radiation Oncology, Calvary Mater Newcastle, Waratah, New South Wales 2298, Australia and School of Medicine and Population Health, University of Newcastle, New South Wales 2308 (Australia)

2011-10-15T23:59:59.000Z

278

Evaluation of Thematic Map Design in Geographical Journals in the 20th Century  

E-Print Network [OSTI]

.010 * 0.290 Readability <0.001* <0.001* Logic of Symbology 0.007 * 0.582 Legend Theme 0.207 0.016 Legend Title 0.678 0.174 Legend Design 0.103 0.056 Scale Meets Conventions 0.024 0.794 Map Projection 0.463 0.148 Title Directness 0.169 0....049 Map Referenced 0.070 <0.001 * *Significant using a modified Bonferroni correction developed by Hochberg (1988); the overall ? was set to 0.15. From Littlehales (Geographical Review 1899, 130) From Finley and Scott (Geographical Review...

Slocum, Terry A.

2011-11-16T23:59:59.000Z

279

Drive train design, construction, and evaluation for a powered cart for third world farmers  

E-Print Network [OSTI]

Recommended Grades for Rural Roads Ve rc e Nax. Sustarne Grade (%) Nax. Gra e (%) 2, 3, a4-wheel tractor/trailer Pickup truck Trucks, & 5-tons Trucks, & 5-tons 4 wheel drive 6 12 12 10 20 10 18 18 15 30 A apte rom Been a er et a Vehicles... remains to determine the feasibility for a large company to take on the project. The design work done to date has stressed simplicity for ease of manufacture and repair in the Third World. The vehicle construction could be a part of a more...

Kittelson, David Andrew

2012-06-07T23:59:59.000Z

280

Interconnection Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Bioenergy Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Water Buying & Making Electricity Solar Home Weatherization Wind Program Info State Kansas Program Type Interconnection Provider Kansas Corporation Commission Kansas adopted the Net Metering and Easy Connection Act in May 2009 (see K.S.A. 66-1263 through 66-1271), establishing interconnection guidelines and net metering for customer-owned generators. Net metering and the accompanying interconnection guidelines apply to systems that generate electricity using solar, wind, methane, biomass or hydro resources, and to fuel cells using hydrogen produced by an eligible renewable technology, with a rated capacity of 25 kilowatts (kW) or less for residential customers, 200 kW or less for non-residential customers and 1.5 megawatts

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Guidelines for Ecological Risk Assessment  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

5/002F 5/002F April 1998 Guidelines for Ecological Risk Assessment (Published on May 14, 1998, Federal Register 63(93):26846-26924) Risk Assessment Forum U.S. Environmental Protection Agency Washington, DC DISCLAIMER This document has been reviewed in accordance with U.S. Environmental Protection Agency policy and approved for publication. Mention of trade names or commercial products does not constitute endorsement or recommendation for use. NOTICE This report contains the full text of the Guidelines for Ecological Risk Assessment. However, the format of this version differs from the Federal Register version, as follows: text boxes that are included in this document at their point of reference were instead listed at the end of the Federal Register document as text notes, due to format limitations for Federal Register documents.

282

Using Post-Occupancy Evaluation to Inform Design and Improve Performance  

E-Print Network [OSTI]

p p ro a c h e s t o p e rf o rm a n c e actual performance – lighting 0 20 40 60 80 100 Gloria Marshall ES Garrett ES York ES * highest rating in SHW study * Re-site Partial re-site New design %age satisfaction rate ESL-KT-13-12-15 CATEE 2013...: Clean Air Through Energy Efficiency Conference, San Antonio, Texas Dec. 16-18 0 5 10 15 20 25 30 35 Gloria Marshall ES Garrett ES York ES Actual 25.2 kBTU/sqft/yr Predicted 18.4 kBTU/sqft/yr Actual 23.9 kBTU/sqft/yr Predicted 32.3 kBTU/sqft/yr No energy...

Langer, S.

2013-01-01T23:59:59.000Z

283

A design methodology for unattended monitoring systems  

SciTech Connect (OSTI)

The authors presented a high-level methodology for the design of unattended monitoring systems, focusing on a system to detect diversion of nuclear materials from a storage facility. The methodology is composed of seven, interrelated analyses: Facility Analysis, Vulnerability Analysis, Threat Assessment, Scenario Assessment, Design Analysis, Conceptual Design, and Performance Assessment. The design of the monitoring system is iteratively improved until it meets a set of pre-established performance criteria. The methodology presented here is based on other, well-established system analysis methodologies and hence they believe it can be adapted to other verification or compliance applications. In order to make this approach more generic, however, there needs to be more work on techniques for establishing evaluation criteria and associated performance metrics. They found that defining general-purpose evaluation criteria for verifying compliance with international agreements was a significant undertaking in itself. They finally focused on diversion of nuclear material in order to simplify the problem so that they could work out an overall approach for the design methodology. However, general guidelines for the development of evaluation criteria are critical for a general-purpose methodology. A poor choice in evaluation criteria could result in a monitoring system design that solves the wrong problem.

SMITH,JAMES D.; DELAND,SHARON M.

2000-03-01T23:59:59.000Z

284

Mechanical Design and Evaluation of the MP-11-Like Wire Scanner Prototype  

SciTech Connect (OSTI)

A wire scanner (WS) is a linearly actuated diagnostic device that uses fiber wires (such as Tungsten or Silicon Carbide) to obtain the position and intensity profile of the proton beam at the Los Alamos Neutron Science Center (LANSCE) particle accelerator. LANSCE will be installing approximately 86 new WS in the near future as part of the LANSCE Risk Mitigation project. These 86 new WS include the replacement of many current WS and some newly added to the current linear accelerator and other beam lines. The reason for the replacement and addition of WS is that many of the existing actuators have parts that are no longer readily available and are difficult to find, thus making maintenance very difficult. One of the main goals is to construct the new WS with as many commercially-available-off-the-shelf components as possible. In addition, faster beam scans (both mechanically and in term of data acquisition) are desired for better operation of the accelerator. This document outlines the mechanical design of the new MP-11-like WS prototype and compares it to a previously built and tested SNS-like WS prototype.

Rodriguez Esparza, Sergio [Los Alamos National Laboratory; Sedillo, James Daniel [Los Alamos National Laboratory; Maestas, Alfred J. [Los Alamos National Laboratory; Gilpatrick, John D. [Los Alamos National Laboratory; Smith, Brian G. [Los Alamos National Laboratory; Raybun, Joseph L. [Los Alamos National Laboratory; Martinez, Jason P. [Los Alamos National Laboratory; Sattler, F. D. [Los Alamos National Laboratory; Gruchalla, Michael E. [Los Alamos National Laboratory

2012-05-16T23:59:59.000Z

285

Evaluation of design options for improving the energy efficiency of an environmentally safe domestic refrigerator-freezer  

SciTech Connect (OSTI)

In order to reduce greenhouse emissions from power plants and respond to regulatory actions arising from the National Appliance Energy Conservation Act (NAECA), several design options were investigated for improving the energy efficiency of a conventionally designed, domestic refrigerator-freezer. The options, such as improved cabinet insulation and high-efficiency compressor and fans, were incorporated into a prototype refrigerator-freezer cabinet and refrigeration system to produce a unit that is superior from an environmental viewpoint due to its lower energy consumption and the use of refrigerant HFC-134a as a replacement for CFC-12. Baseline energy performance of the original 1993 production refrigerator-freezer, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. A detailed refrigerator system computer model was used to evaluate the energy savings for several design modifications that, collectively, could achieve a targeted energy consumption of 1.00 kWh/d for a 20 ft{sup 3} (570 l) top-mount, automatic-defrost, refrigerator-freezer. The energy consumption goal represents a 50% reduction in the 1993 NAECA standard for units of this size. Following the modeling simulation, laboratory prototypes were fabricated and tested to experimentally verify the analytical results and aid in improving the model in those areas where discrepancies occurred. While the 1.00 kWh/d goal was not achieved with the modifications, a substantial energy efficiency improvement of 22% (1.41 kWh/d) was demonstrated using near-term technologies. It is noted that each improvement exacts a penalty in terms of increased cost or system complexity/reliability. Further work on this project will analyze cost-effectiveness of the design changes and investigate alternative, more-elaborate, refrigeration system changes to further reduce energy consumption.

Vineyard, E.A.; Sand, J.R. [Oak Ridge National Lab., TN (United States); Bohman, R.H.

1995-03-01T23:59:59.000Z

286

Current guidelines produce competent endovascular surgeons  

Science Journals Connector (OSTI)

Objective This study was conducted to evaluate the safety of percutaneous endovascular procedures (PEPs) during integration of endovascular skills into an urban academic vascular surgery practice and assess the hypothesis that currently accepted guidelines are a valid benchmark for endovascular competency. Methods From 2000 through 2004, an endovascular training paradigm was instituted to integrate endovascular procedures into an academic endovascular practice. The paradigm involved individual mentoring of vascular surgery faculty by a partner with mature endovascular skills. Mentoring continued until each surgeon achieved a procedural experience of 100 diagnostic angiograms and 50 percutaneous endovascular interventions. Once achieved, privileges were granted for independent endovascular practice. To assess the effectiveness of the training process and competency of the newly trained endovascular practitioner, the surgeon-specific 30-day incidence of major complications and deaths for all \\{PEPs\\} performed during and after the mentoring process was determined. Complications and deaths were assigned to the mentor during the training process and to the individual surgeon once endovascular privileges were granted. Complications were classified as local vascular, local nonvascular, or systemic/remote. Results From 2000 through 2004, 1208 \\{PEPs\\} were performed. During this time, three faculty surgeons achieved sufficient endovascular procedural experience and were granted endovascular privileges. Major complications consisted of 17 local vascular, three local nonvascular, and four systemic/remote. Three deaths occurred. Renal percutaneous transluminal angioplasty/stent procedures had the highest complication and death rate at 9%. The major complication and death rate per year was 1.8% to 4.9% (P = .32) and did not significantly vary. The major complication and death rate for all 1208 \\{PEPs\\} was 2.2%. The surgeon-specific complication and death rate was 1.9% to 3.6% (P = .14) and did not vary between surgeons. Conclusion Endovascular skills can be safely transferred using a vascular surgeon-based training paradigm. When the training paradigm is directed at satisfying currently recommended guidelines for endovascular privileging, competent endovascular surgeons are the result.

Fred A. Weaver; Douglas B. Hood; Haimesh Shah; Jason Alexander; Steven Katz; Vincent Rowe; Albert E. Yellin

2006-01-01T23:59:59.000Z

287

Inorganic ion exchange evaluation and design: Silicotitanate ion exchange waste conversion  

SciTech Connect (OSTI)

Ion exchange materials are being evaluated for removing Cs, SR from tank waste. Thermal conversion of a variety of compositions within the Cs{sub 2}O-TiO{sub 2}-SiO{sub 2} phase diagram yielded both glass and crystalline materials, some of which show low leach rates and negligible Cs losses during heat treatment. A new material, CsTiSi{sub 2}0{sub 6}, with a structure isomorphous to pollucite (CsAlSi{sub 2}0{sub 6}) has been identified. This material represents a new class of crystalline zeolite materials which contain large amounts of titanium. Direct conversion of Cs loaded silicotitanate ion exchangers to CsTiSi{sub 2}O{sub 6} is an excellent alternative to dissolving the Cs-loaded or Cs-eluted exchangers in borosilicate glass because: CsTiSi{sub 2}O{sub 6} is formed using a simple, one step heat treatment. The unique crystalline pollucite-like structure of CsTiSi{sub 2}O{sub 6} traps Cs, and exhibits extremely low Cs leach rates. CsTiSi{sub 2}O{sub 6} is converted to solid waste at a low processing temperature of 700 to 800 C (nominal melter operating temperatures are 1150 C). CsTiSi{sub 2}0{sub 6} concentrates the waste, thus generating lower volumes of expensive HLW. Cs losses due to volatilization during processing of CsTiSi{sub 2}O{sub 6} are extremely low.

Balmer, M.L.; Bunker, B.C.

1995-03-01T23:59:59.000Z

288

Memorandum, Adjudicative Guidelines Implementation - February 21, 2006 |  

Broader source: Energy.gov (indexed) [DOE]

Adjudicative Guidelines Implementation - February 21, Adjudicative Guidelines Implementation - February 21, 2006 Memorandum, Adjudicative Guidelines Implementation - February 21, 2006 February 21,2006 The following adjudicative guidelines are established for all U.S. government civilian and military personnel, consultants, contractors, employees of contractors, licensees, certificate holders or grantees and their employees and other individuals who require access to classified information. "On December 29,2005, the President approved a revision of the Adjudicative Guidelines for Determining Eligibility for Access to Classified Information. The revised guidelines were distributed as an attachment to a memorandum f?om Stephen J. Hadley, Assistant to the President for National Security Affairs, addressed to William Leonard, Director of the Information Security

289

Guidelines for identifying suspect/counterfeit material  

SciTech Connect (OSTI)

These guidelines are intended to assist users of products in identifying: substandard, misrepresented, or fraudulently marked items. The guidelines provide information about such topics as: precautions, inspection and testing, dispositioning identified items, installed inspection and reporting suspect/counterfeit materials. These guidelines apply to users who are developing procurement documents, product acceptance/verification methods, company procedures, work instructions, etc. The intent of these SM guidelines in relation to the Quality Assurance Program Description (QAPD) and implementing company Management Control Procedures is not to substitute or replace existing requirements, as defined in either the QAPD or company implementing instructions (Management Control Procedures). Instead, the guidelines are intended to provide a consolidated source of information addressing the issue of Suspect/Counterfeit materials. These guidelines provide an extensive suspect component listing and suspect indications listing. Users can quickly check their suspect items against the list of manufacturers products (i.e., type, LD. number, and nameplate information) by consulting either of these listings.

NONE

1995-09-01T23:59:59.000Z

290

Guidelines for Selecting Cool Roofs  

Broader source: Energy.gov (indexed) [DOE]

BUILDING TECHNOLOGIES PROGRAM BUILDING TECHNOLOGIES PROGRAM Guidelines for Selecting Cool Roofs July 2010 V. 1.2 Prepared by the Fraunhofer Center for Sustainable Energy Systems for the U.S. Department of Energy Building Technologies Program and Oak Ridge National Laboratory under contract DE-AC05-00OR22725. Additional technical support provided by Lawrence Berkeley National Laboratory and the Federal Energy Management Program. Authors: Bryan Urban and Kurt Roth, Ph.D. ii Table of Contents Introduction ..................................................................................................................................... 3 Why Use Cool Roofs .............................................................................................................. 3

291

ENERGY STAR Guidelines for Energy Management  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Guidelines for Energy Guidelines for Energy Management ENERGY STAR is a U.S. Environmental Protection Agency Program helping organizations and individuals fight climate change through superior energy efficiency. Learn more at energystar.gov/buildings. 2 ENERGY STAR Guidelines for Energy Management Overview Continuous improvement of energy performance requires establishing effective energy management practices and processes to guide the energy program. Any organization, regardless of size, function, or mission can develop an effective energy program if they are willing to make the commitment. The US EPA's ENERGY STAR Guidelines for Energy Management provides a proven strategy for creating an energy management program focused on continuous improvement of energy performance. The

292

Regulations, Guidelines and Codes and Standards  

Broader source: Energy.gov [DOE]

Many regulations, guidelines, and codes and standards have already been established through years of hydrogen use in industrial and aerospace applications. In addition, systems and organizations...

293

Underwriting Guidelines for Residential Loan Programs | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

forms of security may be necessary. State and local governments and their financial advisor(s) should negotiate the underwriting guidelines with the financial institution...

294

MATLAB Programming Style Guidelines Richard Johnson  

E-Print Network [OSTI]

MATLAB Programming Style Guidelines Richard Johnson Version 1.5 October 2002 Copyright © 2002............................................................................................................................................13 #12;Introduction Advice on writing MATLAB code usually addresses efficiency concerns

Born, Richard

295

INFORMATION SECURITY GUIDELINES TABLE OF CONTENTS  

E-Print Network [OSTI]

INFORMATION SECURITY GUIDELINES #12;CONSISTENT, EFFECTIVE INFORMATION SECURITY To respond to societal-to-date information security standards. Should we fail to do so, in the event

Prodiæ, Aleksandar

296

Energy Department Launches Better Buildings Workforce Guidelines...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

energy-related jobs: Energy Auditor, Commissioning Professional, BuildingStationary Engineer, Facility Manager, and Energy Manager. These voluntary workforce guidelines will...

297

Strategy Guideline: Compact Air Distribution Systems  

SciTech Connect (OSTI)

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

Burdick, A.

2013-06-01T23:59:59.000Z

298

EIA-Voluntary Reporting of Greenhouse Gases Program - Reporting Guidelines  

U.S. Energy Information Administration (EIA) Indexed Site

Reporting Guidelines Reporting Guidelines Voluntary Reporting of Greenhouse Gases Program Reporting Guidelines The purpose of the guidelines is to establish the procedures and requirements for filing voluntary reports, and to ensure that the annual reports of greenhouse gas emissions, emission reductions, and sequestration activities submitted by corporations, government agencies, non-profit organizations, households, and other private and public entities to submit are complete, reliable, and consistent. Over time, it is anticipated that these reports will provide a reliable record of the contributions reporting entities have made toward reducing their greenhouse gas emissions. General Guidelines General Guidelines Technical Guidelines Technical Guidelines Appendices to the Technical Guidelines:

299

2008 Guidelines to Defra's GHG Conversion Factors Guidelines to Defra's GHG Conversion Factors  

E-Print Network [OSTI]

with the standard conversion factors at Annex 1. If, however, you export energy or heat to another business (or2008 Guidelines to Defra's GHG Conversion Factors 2008 Guidelines to Defra's GHG Conversion Factors yellow = Calculation results Page 1 of 15 #12;2008 Guidelines to Defra's GHG Conversion Factors Annex 1

300

Texas A&M University at Galveston GUIDELINES AND PROCEDURES FOR  

E-Print Network [OSTI]

Texas A&M University at Galveston 2012-2013 GUIDELINES AND PROCEDURES FOR: · ANNUAL REVIEW at Galveston will be considered a College of Texas A&M University. All System and University documents and evaluations are required by Texas A&M University at Galveston (TAMUG). The evaluation of the contributions

Boas, Harold P.

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Texas A&M University at Galveston GUIDELINES AND PROCEDURES FOR  

E-Print Network [OSTI]

Texas A&M University at Galveston 2014-2015 GUIDELINES AND PROCEDURES FOR: · ANNUAL REVIEW at Galveston will be considered a College of Texas A&M University. All System and University documents and evaluations are required by Texas A&M University at Galveston (TAMUG). The evaluation of the contributions

Behmer, Spencer T.

302

Measure Guideline: Optimizing the Configuration of Flexible Duct Junction Boxes  

SciTech Connect (OSTI)

This measure guideline offers additional recommendations to heating, ventilation, and air conditioning (HVAC) system designers for optimizing flexible duct, constant-volume HVAC systems using junction boxes within Air Conditioning Contractors of America (ACCA) Manual D guidance (Rutkowski, H. Manual D -- Residential Duct Systems, 3rd edition, Version 1.00. Arlington, VA: Air Conditioning Contractors of America, 2009.). IBACOS used computational fluid dynamics software to explore and develop guidance to better control the airflow effects of factors that may impact pressure losses within junction boxes among various design configurations (Beach, R., Prahl, D., and Lange, R. CFD Analysis of Flexible Duct Junction Box Design. Golden, CO: National Renewable Energy Laboratory, submitted for publication 2013). These recommendations can help to ensure that a system aligns more closely with the design and the occupants' comfort expectations. Specifically, the recommendations described herein show how to configure a rectangular box with four outlets, a triangular box with three outlets, metal wyes with two outlets, and multiple configurations for more than four outlets. Designers of HVAC systems, contractors who are fabricating junction boxes on site, and anyone using the ACCA Manual D process for sizing duct runs will find this measure guideline invaluable for more accurately minimizing pressure losses when using junction boxes with flexible ducts.

Beach, R.; Burdick, A.

2014-03-01T23:59:59.000Z

303

Final safety evaluation report related to the certification of the System 80{sup +} design (Docket No. 52-002). Volume 1, Chapters 1--14  

SciTech Connect (OSTI)

This final safety evaluation report (FSER) documents the technical review of the System 80+ standard design by the US Nuclear Regulatory Commission (NRC) staff. The application for the System 80+ design was submitted by Combustion Engineering, Inc., now Asea Brown Boveri-Combustion Engineering (ABB-CE) as an application for design approval and subsequent design certification pursuant to 10 CFR {section} 52.45. System 80+ is a pressurized water reactor with a rated power of 3914 megawatts thermal (MWt) and a design power of 3992 MWt at which accidents are analyzed. Many features of the System 80+ are similar to those of Abb-CE`s System 80 design from which it evolved. Unique features of the System 80+ design included: a large spherical, steel containment; an in-containment refueling water storage tank; a reactor cavity flooding system, hydrogen ignitors, and a safety depressurization system for severe accident mitigation; a combustion gas turbine for an alternate ac source; and an advanced digitally based control room. On the basis of its evaluation and independent analyses, the NRC staff concludes that ABB-CE`s application for design certification meets the requirements of Subpart B of 10 CFR Part 52 that are applicable and technically relevant to the System 80+ standard design. This document, Volume 1, contains Chapters 1 through 14 of this report.

Not Available

1994-08-01T23:59:59.000Z

304

Design change management in regulation of nuclear fleets: World nuclear association's working groups on Cooperation in Reactor Design Evaluation and Licensing (CORDEL)  

SciTech Connect (OSTI)

The 60 year life of a reactor means that a plant will undergo change during its life. To ensure continuing safety, changes must be made with a full understanding of the design intent. With this aim, regulators require that each operating organisation should have a formally designated entity responsible for complete design knowledge in regard to plant safety. INSAG-19 calls such an entity 'Design Authority'. This requirement is difficult to achieve, especially as the number of countries and utilities operating plants increases. Some of these operating organisations will be new, and some will be small. For Gen III plants sold on a turnkey basis, it is even more challenging for the operating company to develop and retain the full knowledge needed for this role. CORDEL's Task Force entitled 'Design Change Management' is investigating options for effective design change management with the aim to support design standardization throughout a fleet's lifetime by means of enhanced international cooperation within industry and regulators. This paper starts with considering the causes of design change and identifies reasons for the increased beneficial involvement of the plant's original vendor in the design change process. A key central theme running through the paper is the definition of responsibilities for design change. Various existing mechanisms of vendor-operator interfaces over design change and how they are managed in different organisational and regulatory environments around the world are considered, with the functionality of Owners Groups and Design Authority being central. The roles played in the design change process by vendors, utilities, regulators, owners' groups and other organisations such as WANO are considered The aerospace industry approach to Design Authority has been assessed to consider what lessons might be learned. (authors)

Swinburn, R. [CORDEL DCM Task Force, Rolls-Royce Plc (United Kingdom); Borysova, I. [CORDEL, WNA, 22a St.James Sq., London SW1Y 4JH (United Kingdom); Waddington, J. [CORDEL Group (United Kingdom); Head, J. G. [CORDEL Group, GE-Hitachi Nuclear Energy (United Kingdom); Raidis, Z. [CORDEL Group, Candu Energy (United Kingdom)

2012-07-01T23:59:59.000Z

305

Forests and biodiversity UK Forestry Standard Guidelines  

E-Print Network [OSTI]

Forests and biodiversity UK Forestry Standard Guidelines #12;Key to symbols UKFS Requirements;Forests and biodiversity Forestry Commission: Edinburgh UK Forestry Standard Guidelines #12;© Crown Commission in 2011. ISBN 978-0-85538-831-7 FORESTRY COMMISSION (2011). Forests and Biodiversity. UK Forestry

306

DRAFT NISTIR 7628 Revision 1 Guidelines for  

E-Print Network [OSTI]

DRAFT NISTIR 7628 Revision 1 Guidelines for Smart Grid Cyber Security: Vol. 3, Supportive Analyses Revision 1 Guidelines for Smart Grid Cyber Security: Vol. 3, Supportive Analyses and References The Smart as technology advances and as threats to grid security inevitably multiply and diversif

307

GSD Student Forum Student Group Spending Guidelines  

E-Print Network [OSTI]

GSD Student Forum Student Group Spending Guidelines September 2010 Questions regarding this document should be directed to the Student Forum Treasurer Purpose: This document serves to establish for GSD student groups guidelines on appropriate expenditures when using funding provided by Student Forum

308

NREL Assesses National Design Standards for Offshore Wind (Fact...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

summarizes regulations, standards, and guidelines for the design and operation of offshore wind projects in the United States. In 2012, the American Wind Energy Association...

309

Safety Guidelines for Fieldwork Industrial Hygiene and Occupational Safety Department  

E-Print Network [OSTI]

Safety Guidelines for Fieldwork Industrial Hygiene and Occupational Safety Department Environmental Safety Division University of Georgia Adapted from the Safety Guidelines for Field Researchers published by the Office of Environment, Health & Safety at University of California, Berkeley #12;Safety Guidelines

Arnold, Jonathan

310

IPCC Inventory Guidelines LULUCF | Open Energy Information  

Open Energy Info (EERE)

IPCC Inventory Guidelines LULUCF IPCC Inventory Guidelines LULUCF Jump to: navigation, search Tool Summary Name: IPCC Inventory Guidelines LULUCF Agency/Company /Organization: World Meteorological Organization, United Nations Environment Programme Sector: Land Focus Area: Forestry, Agriculture Topics: GHG inventory Resource Type: Guide/manual, Lessons learned/best practices Website: www.ipcc-nggip.iges.or.jp/public/gpglulucf/gpglulucf_contents.html IPCC Inventory Guidelines LULUCF Screenshot References: IPCC Inventory Guidelines LULUCF[1] "This report on Good Practice Guidance for Land Use, Land-Use Change and Forestry (GPG-LULUCF) is the response to the invitation by the United Nations Framework Convention on Climate Change (UNFCCC) to the Intergovernmental Panel on Climate Change (IPCC) to develop good practice

311

SLAC Lightsource User Access Guidelines and Agreement  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Lightsource User Access Guidelines & Agreement Lightsource User Access Guidelines & Agreement August 3, 2011 SLAC-I-030-306-001-00-R002 1 SLAC Lightsource User Access Guidelines and Agreement LCLS / SSRL User Research Administration approval (signature/date): LCLS Safety Office approval (signature/date): SSRL Safety Office approval (signature/date): XFO Operations approval (signature/date): Revision Record Revision Date Revised Section(s) Affected Description of Change R001 October 4 th , 2010 User Form Updated SLAC Lightsource User Access Agreement Form R000 Sept 14, 2009 Original Release SLAC Lightsource User Access Guidelines & Agreement August 3, 2011 SLAC-I-030-306-001-00-R002 1 SLAC LIGHTSOURCE USER ACCESS GUIDELINES & AGREEMENT Introduction Welcome to SSRL and LCLS, SLAC's lightsource user facilities. We hope that your stay here will be

312

State Energy Assurance Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

State Energy Assurance Guidelines State Energy Assurance Guidelines State Energy Assurance Guidelines The State Energy Assurance Guidelines were developed by the National Association of State Energy Officials (NASEO) with the assistance of the National Association of Regulatory Utility Commissioners (NARUC) under the direction of the U.S. Department of Energy's Office of Electricity Delivery and Energy Reliability (OE). The guidelines integrate the lessons learned from responding to energy emergencies in recent years and from the dialogue that has occurred at conferences, exercises and meetings on energy assurance. They encompass many topics that states may wish to consider incorporating into their plans. Foremost among these is how energy assurance can improve: planning and responding quickly and effectively to

313

Ecological Exposure Limits and Guidelines  

Science Journals Connector (OSTI)

Abstract Ecological exposure limits and guidelines represent the maximum level of a chemical substance that is considered to be safe or acceptable in environmental releases or compartments. The ecological exposure limits are established to protect the ecosystems and environmental resources and may refer to the emissions, e.g., effluents, atmospheric emissions or discharges, or to the final concentration in the receiving body, e.g., water, sediment, or soil. There are two main methods for setting these limits. One focuses on the identification of best available practices for different sectors and processes; the other is a particular case of risk assessment, named by some authors as reverse risk assessment, which establishes the maximum level in the emission or receiving compartment maintaining an acceptable level of risk. The term ‘exposure limit’ is rarely used in the ecological context; the most usual terms are criteria, standards, or objectives.

J.V. Tarazona

2014-01-01T23:59:59.000Z

314

Designing radiation protection signs  

SciTech Connect (OSTI)

Entry into hazardous areas without the proper protective equipment is extremely dangerous and must be prevented whenever possible. Current postings of radiological hazards at the Rocky Flats Environmental Technology Site (RFETS) do not incorporate recent findings concerning effective warning presentation. Warning information should be highly visible, quickly, and easily understood. While continuing to comply with industry standards (e.g., Department of Energy (DOE) guidelines), these findings can be incorporated into existing radiological sign design, making them more effective in terms of usability and compliance. Suggestions are provided for designing more effective postings within stated guidelines.

Rodriguez, M.A.; Richey, C.L.

1995-03-01T23:59:59.000Z

315

Weatherization and Intergovernmental Program: Guidelines for Home Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Guidelines for Home Energy Professionals to someone by E-mail Guidelines for Home Energy Professionals to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on Facebook Tweet about Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on Twitter Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on Google Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on Delicious Rank Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on Digg Find More places to share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals on AddThis.com... Plans, Implementation, & Results Weatherization Assistance Program

316

Building Technologies Office: Guidelines for Home Energy Professionals  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Guidelines for Home Guidelines for Home Energy Professionals to someone by E-mail Share Building Technologies Office: Guidelines for Home Energy Professionals on Facebook Tweet about Building Technologies Office: Guidelines for Home Energy Professionals on Twitter Bookmark Building Technologies Office: Guidelines for Home Energy Professionals on Google Bookmark Building Technologies Office: Guidelines for Home Energy Professionals on Delicious Rank Building Technologies Office: Guidelines for Home Energy Professionals on Digg Find More places to share Building Technologies Office: Guidelines for Home Energy Professionals on AddThis.com... About Take Action to Save Energy Partner With DOE Activities Solar Decathlon Building America Home Energy Score Home Performance with ENERGY STAR

317

M&V Guidelines: Measurement and Verification for Federal Energy...  

Broader source: Energy.gov (indexed) [DOE]

M&V Guidelines: Measurement and Verification for Federal Energy Projects M&V Guidelines: Measurement and Verification for Federal Energy Projects Document describes the Federal...

318

M&V Guidelines: Measurement and Verification for Federal Energy...  

Broader source: Energy.gov (indexed) [DOE]

M&V Guidelines: Measurement and Verification for Federal Energy Projects M&V Guidelines: Measurement and Verification for Federal Energy Projects FEMP's standard procedures and...

319

New Draft of Cybersecurity Risk Management Process (RMP) Guideline...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

New Draft of Cybersecurity Risk Management Process (RMP) Guideline Now Available for Public Comment (March 2012) New Draft of Cybersecurity Risk Management Process (RMP) Guideline...

320

NREL: Technology Deployment - Guidelines for Home Energy Professionals...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Guidelines for Home Energy Professionals Improves Quality of Energy Efficiency Upgrades News Guidelines for Home Energy Professionals: Standard Work Specifications for...

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Thermodynamic Guidelines for the Prediction of Hydrogen Storage...  

Broader source: Energy.gov (indexed) [DOE]

Thermodynamic Guidelines for the Prediction of Hydrogen Storage Reactions and Their Application to Destabillzed Hydride Mixtures Thermodynamic Guidelines for the Prediction of...

322

Better Buildings Workforce Guidelines for Facility Energy Manager...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Guidelines for Facility Energy Manager - 2014 BTO Peer Review Better Buildings Workforce Guidelines for Facility Energy Manager - 2014 BTO Peer Review Presenter: Phil Coleman,...

323

2012 Criteria and Guidelines for the Federal Energy and Water...  

Broader source: Energy.gov (indexed) [DOE]

2012 Criteria and Guidelines for the Federal Energy and Water Management Awards 2012 Criteria and Guidelines for the Federal Energy and Water Management Awards Guide covers the...

324

Northeast Home Heating Oil Reserve - Guidelines for Release ...  

Broader source: Energy.gov (indexed) [DOE]

Heating Oil Reserve Northeast Home Heating Oil Reserve - Guidelines for Release Northeast Home Heating Oil Reserve - Guidelines for Release The Energy Policy and Conservation...

325

Design and techno-economic evaluation of microbial oil production as a renewable resource for biodiesel and oleochemical production  

Science Journals Connector (OSTI)

Abstract Experimental results from the open literature have been employed for the design and techno-economic evaluation of four process flowsheets for the production of microbial oil or biodiesel. The fermentation of glucose-based media using the yeast strain Rhodosporidium toruloides has been considered. Biodiesel production was based on the exploitation of either direct transesterification (without extraction of lipids from microbial biomass) or indirect transesterifaction of extracted microbial oil. When glucose-based renewable resources are used as carbon source for an annual production capacity of 10,000 t microbial oil and zero cost of glucose (assuming development of integrated biorefineries in existing industries utilising waste or by-product streams) the estimated unitary cost of purified microbial oil is $3.4/kg. Biodiesel production via indirect transesterification of extracted microbial oil proved more cost-competitive process compared to the direct conversion of dried yeast cells. For a price of glucose of $400/t  oil production cost and biodiesel production cost are estimated to be $5.5/kg oil and $5.9/kg biodiesel, correspondingly. Industrial implementation of microbial oil production from oleaginous yeast is strongly dependent on the feedstock used and on the fermentation stage where significantly higher productivities and final microbial oil concentrations should be achieved.

Apostolis A. Koutinas; Afroditi Chatzifragkou; Nikolaos Kopsahelis; Seraphim Papanikolaou; Ioannis K. Kookos

2014-01-01T23:59:59.000Z

326

Evaluation of the hazardous waste landfill cap system design and clay layer thickness criteria of the Turkish Regulation on the Control of Hazardous Waste (RCHW) using the Hydrological Evaluation of Landfill Performance (HELP) model  

Science Journals Connector (OSTI)

The hazardous waste landfill design criteria of the Turkish Regulation on the Control of Hazardous Waste (RCHW) was evaluated in this study. In the first part of the study, Hydrologic Evaluation of Landfill Performance (HELP) model was used to determine the significance of different components of the hazardous waste landfill cap system as required by the Turkish RCHW. In the second part of the study, the top and bottom clay layer thickness requirement of the Turkish RCHW was evaluated by running the HELP model for different top/bottom clay different layer thicknesses and comparing the corresponding leachate amounts produced.

F. Yalcin Piskin; G.N. Demirer

2007-01-01T23:59:59.000Z

327

Interconnection Guidelines (Rhode Island) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Interconnection Guidelines (Rhode Island) Interconnection Guidelines (Rhode Island) Interconnection Guidelines (Rhode Island) < Back Eligibility Agricultural Commercial Fed. Government Industrial Institutional Local Government Multi-Family Residential Nonprofit Residential Schools State Government Savings Category Bioenergy Alternative Fuel Vehicles Hydrogen & Fuel Cells Buying & Making Electricity Water Solar Home Weatherization Wind Program Info State Rhode Island Program Type Interconnection Provider Rhode Island Public Utilities Commission Rhode Island enacted legislation (HB 6222) in June 2011 to standardize the application process for the interconnection of customer-sited renewable-energy systems to the state's distribution grid. Rhode Island's interconnection policy is not nearly as comprehensive as

328

Knowledge of UK physical activity guidelines: Implications for better targeted health promotion  

Science Journals Connector (OSTI)

AbstractObjective The aim of this study is to investigate the correlates of knowledge of the UK physical activity (PA) guidelines. Method A Northern Ireland-wide population survey (2010/2011) of 4653 adults provided cross-sectional data on PA, knowledge of guidelines and socio-demographic characteristics. Multinomial logistic regression was used to investigate the associations between knowledge and socio-demographic characteristics (Model 1); and modifiable health behaviours (Model 2). Results Results showed that 47% of respondents were unaware of PA guidelines. Males who had a lower level of education (OR 5.91; 95% CI 1.67, 20.94), lived in more deprived areas (OR 4.80; 95% CI 1.87, 12.30), low income (OR 2.36; 95% CI 1.63, 3.41) and did no PA (OR 2.74; 95% CI 1.31, 5.76) were more likely to be unaware of the guidelines. Females who were younger (OR 1.03; 95% CI 1.02, 1.05) and reported poor health (OR 2.71; 95% CI 1.61, 4.58) were more likely to be unaware of the guidelines. Conclusion There is a lack of awareness about the levels of PA needed to promote health. An understanding of the characteristics of those who are unaware of the guidelines has important implications for the design of targeted, effective health promotion.

Ruth F. Hunter; Mark A. Tully; Paul Donnelly; Michael Stevenson; Frank Kee

2014-01-01T23:59:59.000Z

329

Design and performance evaluation of an electric go-kart and custom permanent magnet brushless DC motor  

E-Print Network [OSTI]

This undergraduate thesis documents the design considerations and specifications of building a personal battery-powered go-kart. This includes designing and building a custom brushless DC motor for use in the drivetrain. ...

Davis, Eli Marc

2012-01-01T23:59:59.000Z

330

Design of an autonomous underwater vehicle to evaluate the blazed array sonar and simultaneous localization and mapping algorithms  

E-Print Network [OSTI]

This thesis has investigated aspects of the design of a new highly maneuverable Autonomous Underwater Vehicle - the XAUV. The overall goal for the design of this vehicle is to create a small, highly maneuverable AUV that ...

Uhle, Matthew William

2007-01-01T23:59:59.000Z

331

Electric Vehicle Charging Infrastructure Deployment Guidelines: British  

Open Energy Info (EERE)

Electric Vehicle Charging Infrastructure Deployment Guidelines: British Electric Vehicle Charging Infrastructure Deployment Guidelines: British Columbia Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Electric Vehicle Charging Infrastructure Deployment Guidelines: British Columbia Agency/Company /Organization: Natural Resources Canada, British Columbia Hydro and Power Authority Focus Area: Vehicles Topics: Best Practices Website: www.bchydro.com/etc/medialib/internet/documents/environment/EVcharging A major component of winning public acceptance for plug-in vehicles is the streamlining of the private electric vehicle charging or supply equipment permitting and installation process as well as the public and commercial availability of charging locations. These guidelines are intended to anticipate the questions and requirements to ensure customer satisfaction.

332

Policies, Procedures and Guidelines Complete Policy Title  

E-Print Network [OSTI]

processes to promote development and operation of sustainable buildings. #12;Policies, Procedures and Guidelines Complete Policy Title: Sustainable Building Policy Policy this electronic policy and the written copy held by the policy owner, the written copy prevails. Sustainable

Haykin, Simon

333

COGNITIVE SCIENCE SENIOR HONORS THESIS GUIDELINES  

E-Print Network [OSTI]

COGNITIVE SCIENCE SENIOR HONORS THESIS GUIDELINES Students interested in pursuing graduate study should seriously consider the Cognitive Science departmental honors program. Students participating in the departmental honors program gain research skills, in depth knowledge of a particular cognitive science area

Indiana University

334

Poster Guidelines - Cyclotron Institute REU Program  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Student Poster Guidelines * Posters should be made such that they can scale easily to 40" x 30" * Posters can be no wider than 35.6" (this is the limitation of our plotter) * White...

335

Social Innovation Fellowship Program Guidelines & Application Materials  

E-Print Network [OSTI]

8/25/2011 Social Innovation Fellowship Program Guidelines & Application Materials Introduction The Social Innovation Fellowship program was created in order to support Stanford Graduate School of Business drive social innovation and transformation in various fields including education, health, environment

Ford, James

336

Fire Protection Program Guidelines | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

14, 1995 Guidelines for Developing Medical Standards for Fire Fighters December 1994 Primer on Spontaneous Heating and Pyrophoricity (DOE-HDBK-1081-94) Oct 1994 Guidance for the...

337

Module 9: Acts, Codes, Regulations and Guidelines  

Broader source: Energy.gov [DOE]

This course covers the mandating of alternative fuel vehicles in the US, the codes, regulations, and guidelines concerning the use of hydrogen, where to look for additional information on hydrogen standards

338

Introduction to NISTIR 7628 Guidelines for  

E-Print Network [OSTI]

Introduction to NISTIR 7628 Guidelines for Smart Grid Cyber Security The Smart Grid................................................................................................................3 2. Cyber Security Context: Today's Grid, Tomorrow's Smart Grid...........................................................17 4.1 Research and Development Themes for Smart Grid Cyber Security

339

Safety and Operational Guidelines | Open Energy Information  

Open Energy Info (EERE)

a stub. You can help OpenEI by expanding it. Retrieved from "http:en.openei.orgwindex.php?titleSafetyandOperationalGuidelines&oldid542700" Categories: Stubs EZFeed Stubs...

340

Grantee Checklist for the Guidelines and Standards Requirement  

Broader source: Energy.gov [DOE]

This document walks Grantees through the Guidelines and Standards requirement of the Quality Work Plan.

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Guidelines for Energy Efficient Schools  

E-Print Network [OSTI]

control is a hybrid HVAC system with a designed mixture or balance between electric and natural gas energy sources. The summary of this paper will compare operating cost performance, energy performance, HVAC system type of the case study schools, eight...

McClure, J. D.; Estes, J. M.; Bicknell, K. N.; Estes, M. C.

1988-01-01T23:59:59.000Z

342

Perspective on Beyond Design Basis Event Analysis and Response | Department  

Broader source: Energy.gov (indexed) [DOE]

Perspective on Beyond Design Basis Event Analysis and Response Perspective on Beyond Design Basis Event Analysis and Response Perspective on Beyond Design Basis Event Analysis and Response September 20, 2012 Presenter: John Schwenker, Nuclear Safety Manager for Liquid Operations, Savannah River Remediation, LLC, Savannah River Site Topics Covered: Waste Tanks can contain up to 1.3 Millions Gallons of highly radioactive waste (sludge, salt, supernate). Type III/IIIA Waste Tank Structures and berms are PC-3 Qualified. Tanks may fail in a Beyond Design Basis Seismic Event. Waste could flow above ground to streams and rivers. Unmitigated Tank Explosion exceeds offsite Evaluation Guidelines Hydrogen gas can be trapped in the sludge and saltcake structure. Seismic Event can cause a prompt release of trapped hydrogen. It is not physically practical to install a ventilation system that

343

Measure Guideline: Installing Rigid Foam Insulation on the Interior of Existing Brick Walls  

SciTech Connect (OSTI)

This measure guideline provides information on an effective method to insulate the interior of existing brick masonry walls with extruded polystyrene (XPS) insulation board. The guide outlines step-by-step design and installation procedures while explaining the benefits and tradeoffs where applicable. The authors intend that this document be useful to a varied audience that includes builders, remodelers, contractors and homeowners.

Natarajan, H.; Klocke, S.; Puttagunta, S.

2012-06-01T23:59:59.000Z

344

CNS-ProjectManagement-Guidelines-200010.doc 1 / 3 CNS Project Management Procedures and Guidelines  

E-Print Network [OSTI]

CNS-ProjectManagement-Guidelines-200010.doc 1 / 3 CNS Project Management Procedures and Guidelines (Rev. October 2000) Staffing and Project Management This section is intended to provide business an application. Following an analysis phase, which may be performed by CNS in collaboration with the project

Shihadeh, Alan

345

AOCE Petition Guidelines **These guidelines apply to the following Continuing Education Programs: Lifelong Learning, Test Prep,  

E-Print Network [OSTI]

AOCE Petition Guidelines **These guidelines apply to the following Continuing Education Programs-9359 Fax: 801-585-6490 Email: register@aoce.utah.edu 4. Please allow up to 4 weeks for the petition Drive 1185 Annex, Salt Lake City, UT 84112-9359 Fax: 801-585-6490 Email: register@aoce.utah.edu 5

Capecchi, Mario R.

346

Poster Guidelines We have guidelines for you when preparing your poster presentation for the 2013 SWAT  

E-Print Network [OSTI]

Poster Guidelines We have guidelines for you when preparing your poster presentation for the 2013 SWAT Conference in Toulouse. Please note the following: · Poster boards will accommodate A0 size portrait posters: height 1189 mm (46.8 inches), width 841 mm (33.1 inches). Please ensure that your display

347

Green Fund Proposal Guidelines September 15, 2010 UNBC GREEN FUND PROPOSAL GUIDELINES  

E-Print Network [OSTI]

Green Fund Proposal Guidelines September 15, 2010 UNBC GREEN FUND PROPOSAL GUIDELINES In order to advance the overall sustainability of UNBC as an institution a "UNBC Green Fund" has been created from UNBC parking revenues. Green research and project proposals will be accepted by the Green University

Northern British Columbia, University of

348

Green Fund Proposal Guidelines August 10, 2012 UNBC GREEN FUND PROPOSAL GUIDELINES  

E-Print Network [OSTI]

Green Fund Proposal Guidelines August 10, 2012 UNBC GREEN FUND PROPOSAL GUIDELINES In order to advance the overall sustainability of UNBC as an institution a "UNBC Green Fund" has been created from UNBC parking revenues. Green research and project proposals are accepted by the Green University

Northern British Columbia, University of

349

Green Fund Proposal Guidelines March 15, 2010 UNBC GREEN FUND PROPOSAL GUIDELINES  

E-Print Network [OSTI]

Green Fund Proposal Guidelines March 15, 2010 UNBC GREEN FUND PROPOSAL GUIDELINES In order to advance the overall sustainability of UNBC as an institution a "UNBC Green Fund" has been created from UNBC parking revenues. Green research and project proposals will be accepted by the Green University

Northern British Columbia, University of

350

Design Guidelines for Audio Presentation of Graphs and Tables  

E-Print Network [OSTI]

Brown,L.M. Brewster,S.A. Ramloll,R. Burton,M. Riedel,B. ICAD 2003 Workshop on Auditory Displays In Assistive Technologies, Boston, M.A. International Conference on Auditory Display

Brown, L.M.; Brewster, S.A.

351

Wearable Computers: Field-Test Results and System Design Guidelines  

Science Journals Connector (OSTI)

Since the summer of 1994, a group of partners, led by Boeing and including Carnegie Mellon University, Virtual Vision ... in Sacramento, California, autopilot troubleshooting for the Boeing 777, and fuel system p...

Chris Esposito

1997-01-01T23:59:59.000Z

352

Wearable computers: Field-test observations and system design guidelines  

Science Journals Connector (OSTI)

Since the summer of 1994, a group of partners, led by Boeing and including Carnegie Mellon University, Virtual Vision ... in Sacramento, California, autopilot troubleshooting for the Boeing 777, and fuel system p...

Chris Esposito

1997-01-01T23:59:59.000Z

353

Building Automation Systems Design. Guidelines for Systems with Complex Requirements.  

E-Print Network [OSTI]

??Buildings today are becoming more and more advanced and the demands on building services are increasing. A modern building is expected to provide a number… (more)

Kensby, Johan

2012-01-01T23:59:59.000Z

354

Hybrid user interfaces : design guidelines and implementation examples  

E-Print Network [OSTI]

A hybrid user interface is a new type of computer user interface that achieves high usability by combining features of graphical user interfaces and command line interfaces. The main goal of a hybrid user interface is to ...

Ahn, Sehyun

2006-01-01T23:59:59.000Z

355

Substations: landscape guidelines for site selection, design, construction and maintenance.  

E-Print Network [OSTI]

??Most of New Zealand's facilities for the bulk generation and transmission of electricity are owned and operated by New Zealand Electricity, a division of the… (more)

Simmons, Janice R.

1982-01-01T23:59:59.000Z

356

Thermodynamic Guidelines for the Prediction of Hydrogen Storage Reactions and Their Application to Destabillzed Hydride Mixtures  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Thermodynamic guidelines for the prediction of hydrogen Thermodynamic guidelines for the prediction of hydrogen storage reactions and their application to destabilized hydride mixtures Hydrogen Storage & Nanoscale Modeling Group Ford Motor Company Don Siegel dsiegel2@ford.com Phys. Rev. B 76, 134102 (2007) 1 Acknowledgements C. Wolverton V. Ozolins Computation Northwestern UCLA J. Yang A. Sudik Experiments Ford Ford 2 Computational Methodology * Atomistic computer simulations based on quantum mechanics (Density Functional Theory) * First-principles approach: - Only empirical input are crystal structure and fundamental physical constants - VASP code - PAW potentials - PW91 GGA - Temperature-dependent thermodynamic contributions evaluated within harmonic approximation * "Direct method" for construction of dynamical matrix

357

Sage-Grouse Lek Guideline Review Report  

SciTech Connect (OSTI)

On April 21, 2011, an Idaho National Laboratory (INL) Land Use Committee meeting was convened to support a Department of Energy Idaho Operations Office (DOE-ID) unofficial request to obtain Land Use Committee comments pertaining to the proposed Sage-Grouse Breeding Habitat Regulations. Two documents were provided from DOE-ID pertaining to the proposed regulations: “Guidelines for INL Site Activities within Sage-grouse Breeding Habitat” and “Guidelines for New Infrastructure Development and Future Activities on the INL Site.” The INL Land Use Committee agreed to conduct this unofficial review in the spirit of collaboration between DOE-ID and the INL Land Use Committee. However, through this cursory review, significant concerns were raised regarding the guidelines, INL financial obligations, and the draft Candidate Conservation Agreement, which was not part of the requested review but is referred to by the guideline. Therefore, it is the position of the INL Land Use Committee, based on the issues raised in its cursory review, that DOE-ID request INL (through contractual channels) to conduct a formal review of the draft Candidate Conservation Agreement and guidelines. A formal review would allow ample time to thoroughly review the extensive draft regulations, identify areas of concern, and establish impacts (e.g., cost and project delays).

John Reisenauer

2011-05-01T23:59:59.000Z

358

7-117 The claim of a heat pump designer regarding the COP of the heat pump is to be evaluated. Assumptions The heat pump operates steadily.  

E-Print Network [OSTI]

7-47 7-117 The claim of a heat pump designer regarding the COP of the heat pump is to be evaluated. Assumptions The heat pump operates steadily. HP Wnet,in QH QL TL TH Analysis The maximum heat pump coefficient of performance would occur if the heat pump were completely reversible, 5.7 K026K300 K300 COP maxHP, LH H TT

Bahrami, Majid

359

Measure Guideline: Energy-Efficient Window Performance and Selection  

SciTech Connect (OSTI)

This document provides guidelines for the selection of energy-efficient windows in new and existing residential construction in all US climate zones. It includes information on window products, their attributes and performance. It provides cost/benefit information on window energy savings as well as information on non-energy benefits such as thermal comfort and reduced HVAC demands. The document also provides information on energy impacts of design decisions such as window orientation, total glazing area and shading devices and conditions. Information on resources for proper window installation is included as well. This document is for builders, homeowners, designers and anyone making decisions about selecting energy efficient window. It is intended to complement other Building America information and efforts.

Carmody, J.; Haglund, K.

2012-11-01T23:59:59.000Z

360

MATE (Materials for Advanced Turbine Engines) Program, Project 3. Volume 2: Design, fabrication and evaluation of an oxide dispersion strengthened sheet alloy combustor liner. Final report  

SciTech Connect (OSTI)

The suitability of wrought oxide dispersion strengthened (ODS) superalloy sheet for gas turbine engine combustor applications was evaluated. Two yttria (Y2O3) dispersion strengthened alloys were evaluated; Incoloy MA956 and Haynes Development Alloy (HDA) 8077 (NiCrAl base). Preliminary tests showed both alloys to be potentially viable combustor materials, with neither alloy exhibiting a significant advantage over the other. MA956 was selected as the final alloy based on manufacturing reproducibility for evaluation as a burner liner. A hybrid PW2037 inner burner liner containing MA956 and Hastelloy X components and using a louvered configuration was designed and constructed. The louvered configuration was chosen because of field experience and compatibility with the bill of material PW2037 design. The simulated flight cycle for the ground based engine tests consisted of 4.5 min idle, 1.5 min takeoff and intermediate conditions in a PW2037 engine with average uncorrected combustor exit temperature of 1527 C. Post test evaluation consisting of visual observations and fluorescent penetrant inspections was conducted after 500 cycles of testing. No loss of integrity in the burner liner was shown.

Bose, S.; Sheffler, K.D.

1988-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Climate VISION: 1605 (B) Reporting Guidelines  

Office of Scientific and Technical Information (OSTI)

Voluntary GHG Reporting Guidelines Voluntary GHG Reporting Guidelines Established by Section 1605(b) of the Energy Policy Act of 1992, the Voluntary Reporting of Greenhouse Gases Program (also known as the 1605(b) Program) encourages corporations, government agencies, non-profit organizations, households, and other private and public entities to submit annual reports of their greenhouse gas emissions, emission reductions, and sequestration activities. The Program provides a means for voluntary reporting that is complete, reliable, and consistent. In February 2002, the President directed the Department of Energy, together with other involved Federal agencies, to recommend reforms to enhance the Voluntary Reporting Program. Following extensive public review, the Program's guidelines underwent an extensive overhaul with the focus of

362

Application of probabilistic risk assessment techniques during design phase for dry storage casks  

SciTech Connect (OSTI)

Canisters containing the Three Mile Island (TMI) spent fuel and debris are being stored in a storage pool at the Idaho National Engineering Laboratory (INEL). In order to store these canisters in dry storage casks, a system is being designed to remove entrained water from the canisters. The conceptual design for this drying process was evaluated in respect to the occurrence of a nuclear criticality. The system design was evaluated to address the mechanical failure of the components. Also, human interfaces with the equipment were assessed. The integration of these two facets resulted in a model that was quantified to calculate the occurrence frequency of a nuclear criticality. Changes to design, administrative guidelines, and procedures were recommended so that an acceptable level of risk based on nuclear criticality occurrence frequency could be achieved. 1 ref., 2 figs.

Hallbert, B.P.; Satterwhite, D.G.; Meale, B.M.

1990-01-01T23:59:59.000Z

363

The problem of designing facades within an industrialized building system : a technical analysis for criticising and evaluating contemporary buildings  

E-Print Network [OSTI]

Designing facades is one of the most important and delicate problems in contemporary architecture. The facade is the changing zone par excelience within which the structural elements of technology meld into refined details ...

Plante, Jacques

1985-01-01T23:59:59.000Z

364

Design and evaluation of a quasi-passive robotic knee brace : on the effects of parallel elasticity on human running  

E-Print Network [OSTI]

While the effects of series compliance on running biomechanics are documented, the effects of parallel compliance are known only for the simpler case of hopping. As many practical exoskeleton and orthosis designs act in ...

Elliott, Grant (Grant Andrew)

2012-01-01T23:59:59.000Z

365

World Bank Good Practice Guidelines: Financial Analysis of Revenue  

Open Energy Info (EERE)

Good Practice Guidelines: Financial Analysis of Revenue Good Practice Guidelines: Financial Analysis of Revenue Generating-Entities Jump to: navigation, search Tool Summary Name: World Bank Good Practice Guidelines: Financial Analysis of Revenue Generating-Entities Agency/Company /Organization: World Bank Topics: Finance Resource Type: Guide/manual Website: siteresources.worldbank.org/INTRANETFINANCIALMGMT/Resources/FMB-Notes/ References: World Bank Good Practice Guidelines: Financial Analysis of Revenue Generating-Entities[1] References ↑ "World Bank Good Practice Guidelines: Financial Analysis of Revenue Generating-Entities" Retrieved from "http://en.openei.org/w/index.php?title=World_Bank_Good_Practice_Guidelines:_Financial_Analysis_of_Revenue_Generating-Entities&oldid=329414"

366

Weatherization and Intergovernmental Program: Guidelines for Home Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Project Updates to someone by Project Updates to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project Updates on Facebook Tweet about Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project Updates on Twitter Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project Updates on Google Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project Updates on Delicious Rank Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project Updates on Digg Find More places to share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project Updates on

367

Weatherization and Intergovernmental Program: Guidelines for Home Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Certifications to someone by Certifications to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Certifications on Facebook Tweet about Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Certifications on Twitter Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Certifications on Google Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Certifications on Delicious Rank Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Certifications on Digg Find More places to share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Certifications on

368

Weatherization and Intergovernmental Program: Guidelines for Home Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Accredited Training to someone by Accredited Training to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Accredited Training on Facebook Tweet about Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Accredited Training on Twitter Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Accredited Training on Google Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Accredited Training on Delicious Rank Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Accredited Training on Digg Find More places to share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Accredited Training on

369

Session: Development and application of guidelines for siting, constructing, operating and monitoring wind turbines  

SciTech Connect (OSTI)

This session at the Wind Energy and Birds/Bats workshop consisted of two presentations followed by a discussion/question and answer period. The two papers were: 'Development and Application of USFWS Guidance for Site Evaluation, Siting, Construction, Operation and Monitoring of Wind Turbines' by Albert Manville and 'Wind Power in Washington State' by Greg Hueckel. The session provided a comparison of wind project guidelines developed by the U.S. Fish and Wildlife Service (USFWS) in May 2003 and the Washington State Department of Fish and Wildlife in August 2003. Questions addressed included: is there a need or desire for uniform national or state criteria; can other states learn from Washington State's example, or from the USFWS voluntary guidelines; should there be uniform requirements/guidelines/check-lists for the siting, operation, monitoring, and mitigation to prevent or minimize avian, bat, and other wildlife impacts.

Manville, Albert; Hueckel, Greg

2004-09-01T23:59:59.000Z

370

Operating Guidelines Appendix A B.DOC  

Broader source: Energy.gov (indexed) [DOE]

Competitive Sourcing Program OPERATING GUIDELINES (CS-OG-01) Competitive Sourcing Program OPERATING GUIDELINES (CS-OG-01) A-1 APPENDIX A. DEFINITIONS AND ACRONYMS A.1 ACRONYMS Acronym Clear Text ATO Agency Tender Official CDRL Contract Data Requirements List C.F.R. Code of Federal Regulations CO Contracting Officer CSO Competitive Sourcing Official DEAR DOE Acquisition Regulation FAIR Federal Activities Inventory Reform FAR Federal Acquisition Regulation FICA Federal Insurance Contribution Act FTE Full-time Equivalent FWS Federal Wage System GAO Government Accounting Office GFP Government-Furnished Property GS General Schedule HCA Head of Contracting Agency HRA Human Resource Advisor MEO Most Efficient Organization OMB Office of Management and Budget

371

Guidelines for Home Energy Professionals Project (Brochure)  

SciTech Connect (OSTI)

The Guidelines for Home Energy Professionals is a collaboration between the U.S. Department of Energy (DOE) and a wide range of home energy performance industry professionals. The Guidelines project, managed by the National Renewable Energy Laboratory (NREL) for DOE, addresses the need for a highly-skilled weatherization workforce equipped to complete consistent, high-quality home energy upgrades for single-family homes, multifamily homes, and manufactured housing. In doing so, it helps increase energy efficiency in housing, which can mitigate climate change, one of the major challenges of the 21st century.

Not Available

2014-03-01T23:59:59.000Z

372

Measure Guideline: High Efficiency Natural Gas Furnaces  

SciTech Connect (OSTI)

This Measure Guideline covers installation of high-efficiency gas furnaces. Topics covered include when to install a high-efficiency gas furnace as a retrofit measure, how to identify and address risks, and the steps to be used in the selection and installation process. The guideline is written for Building America practitioners and HVAC contractors and installers. It includes a compilation of information provided by manufacturers, researchers, and the Department of Energy as well as recent research results from the Partnership for Advanced Residential Retrofit (PARR) Building America team.

Brand, L.; Rose, W.

2012-10-01T23:59:59.000Z

373

E-Print Network 3.0 - alternative tanker designs Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Tech Collection: Engineering 5 OIL TANKER DESIGN METHODOLOGY CONSIDERING PROBABILIS-TIC ACCIDENT DAMAGE Summary: -127. 6 "Interim Guidelines for Approval of Alternative...

374

Electric utility engineer`s FGD manual -- Volume 2: Major mechanical equipment; FGD proposal evaluations; Use of FGDPRISM in FGD system modification, proposal, evaluation, and design; FGD system case study. Final report  

SciTech Connect (OSTI)

Part 2 of this manual provides the electric utility engineer with detailed technical information on some of the major mechanical equipment used in the FGD system. The objectives of Part 2 are the following: to provide the electric utility engineer with information on equipment that may be unfamiliar to him, including ball mills, vacuum filters, and mist eliminators; and to identify the unique technique considerations imposed by an FGD system on more familiar electric utility equipment such as fans, gas dampers, piping, valves, and pumps. Part 3 provides an overview of the recommended procedures for evaluating proposals received from FGD system vendors. The objectives are to provide procedures for evaluating the technical aspects of proposals, and to provide procedures for determining the total costs of proposals considering both initial capital costs and annual operating and maintenance costs. The primary objective of Part 4 of this manual is to provide the utility engineer who has a special interest in the capabilities of FGDPRISM [Flue Gas Desulfurization PRocess Integration and Simulation Model] with more detailed discussions of its uses, requirements, and limitations. Part 5 is a case study in using this manual in the preparation of a purchase specification and in the evaluation of proposals received from vendors. The objectives are to demonstrate how the information contained in Parts 1 and 2 can be used to improve the technical content of an FGD system purchase specification; to demonstrate how the techniques presented in Part 3 can be used to evaluate proposals received in response to the purchase specification; and to illustrate how the FGDPRISM computer program can be used to establish design parameters for the specification and evaluate vendor designs.

NONE

1996-03-04T23:59:59.000Z

375

IPCC Guidelines for National Greenhouse Gas Inventories | Open Energy  

Open Energy Info (EERE)

IPCC Guidelines for National Greenhouse Gas Inventories IPCC Guidelines for National Greenhouse Gas Inventories Jump to: navigation, search Tool Summary Name: IPCC Guidelines for National Greenhouse Gas Inventories Agency/Company /Organization: World Meteorological Organization, United Nations Environment Programme Sector: Energy, Land Topics: GHG inventory, Background analysis Resource Type: Guide/manual, Training materials References: 2006 IPCC Guidelines for National Greenhouse Gas Inventories[1] Logo: IPCC Guidelines for National Greenhouse Gas Inventories "The 2006 IPCC Guidelines for National Greenhouse Gas Inventories (2006 Guidelines) were produced at the invitation of the United Nations Framework Convention on Climate Change(UNFCCC) to update the Revised 1996 Guidelines and associated good practice guidance which provide internationally agreed

376

Building Technologies Office: Guidelines for Participating in the DOE  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Guidelines for Guidelines for Participating in the DOE Challenge Home to someone by E-mail Share Building Technologies Office: Guidelines for Participating in the DOE Challenge Home on Facebook Tweet about Building Technologies Office: Guidelines for Participating in the DOE Challenge Home on Twitter Bookmark Building Technologies Office: Guidelines for Participating in the DOE Challenge Home on Google Bookmark Building Technologies Office: Guidelines for Participating in the DOE Challenge Home on Delicious Rank Building Technologies Office: Guidelines for Participating in the DOE Challenge Home on Digg Find More places to share Building Technologies Office: Guidelines for Participating in the DOE Challenge Home on AddThis.com... About Take Action to Save Energy Partner With DOE

377

TRL Acid and Solvent Wet Processing Rules and Guidelines  

E-Print Network [OSTI]

: General rules and guidelines for wet chemical processing in TRL. Author: KFlo hood and when transporting or handling chemicals. An acid-proof apron, sleeveTRL Acid and Solvent Wet Processing Rules and Guidelines Purpose

Reif, Rafael

378

USGS National Wildlife Health Center Diagnostic Case Submission Guidelines  

E-Print Network [OSTI]

USGS National Wildlife Health Center Diagnostic Case Submission Guidelines The following guidelines broadly outline the framework used by the National Wildlife Health Center (NWHC to the submitting agency, its wildlife populations, or domestic animal and human health. Type of Specimens

379

Operating Guidelines Narrative.DOC | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

More Documents & Publications Operating Guidelines Narrative.DOC&0; Operating Guidelines Appendix A B.DOC&0; O:A76Post Award AccountabilityPCA Handbook.prn.pdf...

380

National Bald Eagle Management Guidelines | Open Energy Information  

Open Energy Info (EERE)

Eagle Management Guidelines Jump to: navigation, search OpenEI Reference LibraryAdd to library Legal Document- OtherOther: National Bald Eagle Management GuidelinesLegal Abstract...

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

LASER SAFETY GUIDELINES July 26, 2006  

E-Print Network [OSTI]

LASER SAFETY GUIDELINES July 26, 2006 #12;TABLE OF CONTENTS SECTION PAGE PREFACE 3 CHAPTER 1: INTRODUCTION TO LASER SAFETY AT PURDUE UNIVERSITY 4 CHAPTER 2: CONTROL MEASURES I. Introduction6 II. Engineering Controls 6 III. Administrative and Procedural Controls 7 IV. Class 3b and 4 Laser Controlled Area

Holland, Jeffrey

382

Policies, Procedures and Guidelines Complete Policy Title  

E-Print Network [OSTI]

Policies, Procedures and Guidelines Complete Policy Title: McMaster University Sustainability a high degree of vegetative surface while limiting the use of pesticides, harmful chemicals and the need; and · experiment with alternative paving methods that will incorporate vegetation. Transportation The University

Haykin, Simon

383

Policies, Procedures and Guidelines Complete Policy Title  

E-Print Network [OSTI]

Policies, Procedures and Guidelines Complete Policy Title: Procedures for Faculty Appeal Tribunals are used in these procedures: 1. `Appellant' means a faculty member who is entitled to appeal a tenure, within the Policy, Section IV, clauses 6(a) and 6(b). II Documents Governing Appeal Procedures

Hitchcock, Adam P.

384

Policies, Procedures and Guidelines Complete Policy Title  

E-Print Network [OSTI]

Policies, Procedures and Guidelines Complete Policy Title: Procedures for University Reviews copy held by the policy owner, the written copy prevails. #12;Procedures for University Reviews of Academic Departments April 28, 2005 1 Procedures for University Reviews of Academic Departments1 I

Haykin, Simon

385

IDENTITY GUIDELINES Natural Environment Research Council  

E-Print Network [OSTI]

-colour reproduction is unavailable. A reverse version can be used on dark backgrounds or images where colour a dark background image or pattern you will need a mono-negative version.These need to be custom: www.nerc.ac.uk/about/enquiries/logos/web/guidelines/ #12;Logo files NERC logo files should

Brierley, Andrew

386

Agriculture and Life Sciences Complex Usage Guidelines  

E-Print Network [OSTI]

Agriculture and Life Sciences Complex Usage Guidelines General Policies 1. Pursuant to Texas A Sciences Complex Usage Request Form and submit a copy to the building manager, Paul Gregg (phone: 979-777-2766, email: paul.gregg@ag.tamu.edu, office: AGLS 517F). The AGLS-ALCT Usage Request Form can be found at

387

GRADUATE PROGRAMS IN Guidelines and Procedures  

E-Print Network [OSTI]

student-faculty interaction. The city of Davis has been called the most "energy-conscious" city Sciences in the College of Letters and Science at UC Davis. The department has sixteen full-time senate1 GRADUATE PROGRAMS IN STATISTICS Guidelines and Procedures UNIVERSITY OF CALIFORNIA, DAVIS Fall

Nguyen, Danh

388

NEW INVESTIGATOR GRANT MRF GRANT REGULATIONS & GUIDELINES  

E-Print Network [OSTI]

NEW INVESTIGATOR GRANT MRF GRANT REGULATIONS & GUIDELINES FOR ADMINISTRATION OF GRANTS AWARDED BY THE MEDICAL RESEARCH FOUNDATION COMMITTEE OF OREGON REGULATIONS 1. MRF grants are awarded to institutions. The grantee institution will account for expenditures at the close of the grant period. 2. Funds will be used

Chapman, Michael S.

389

Indirect Cost Sharing Policies and Guidelines  

E-Print Network [OSTI]

Indirect Cost Sharing Policies and Guidelines University at Albany In the 1997 Fall semester% of the University's indirect cost return to the schools or colleges, departments, and centers. The allocations are determined in direct proportion to the units' contribution toward the total indirect cost recovery pool

Kidd, William S. F.

390

NU Shuttle Advertising Guidelines University Services  

E-Print Network [OSTI]

NU Shuttle Advertising Guidelines University Services Northwestern University operates several,000 · Average monthly one-way rides during the summer: 40,000 Northwestern offers advertising opportunities on its Evanston shuttle bus fleet. Advertising is currently only available to NU-affiliated departments

Shahriar, Selim

391

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE  

E-Print Network [OSTI]

OCCUPATIONAL SAFETY AND ENVIRONMENTAL HEALTH GUIDELINE Subject: Training for the Safe Transportation of Biologics (DOT/IATA Dangerous Goods) Date: 07/03/2006 Revision: 04 Page: 1 of 9 SUMMARY.S. Department of Transportation (DOT) regulates shipping and receiving of biologics as Dangerous Goods

Shyy, Wei

392

SEA TURTLES Guidelines for watching turtles  

E-Print Network [OSTI]

SEA TURTLES Guidelines for watching turtles At night on the beach please follow the following code, turtle watching is best on a full moon. Walk the beach looking for turtle tracks, these will be about 1 metre wide. Follow the tracks carefully and quietly to locate the turtle. Avoid approaching turtles

Exeter, University of

393

Materials for Advanced Turbine Engines (MATE). Project 3: design, fabrication and evaluation of an oxide dispersion strengthened sheet alloy combustor liner. Final Report  

SciTech Connect (OSTI)

The suitability of wrought oxide dispersion strengthened (ODS) superalloy sheet for gas turbine engine combustor applications was evaluated. Incoloy MA 956 (FeCrAl base) and Haynes Developmental Alloy (HDA) 8077 (NiCrAl base) were evaluated. Preliminary tests showed both alloys to be potentially viable combustor materials, with neither alloy exhibiting a significant advantage over the other. Both alloys demonstrated a +167C (300 F) advantage of creep and oxidation resistance with no improvement in thermal fatigue capability compared to a current generation combustor alloy (Hastelloy X). MA956 alloy was selected for further demonstration because it exhibited better manufacturing reproducibility than HDA8077. Additional property tests were conducted on MA956. To accommodate the limited thermal fatigue capability of ODS alloys, two segmented, mechanically attached, low strain ODS combustor design concepts having predicted fatigue lives or 10,000 engine cycles were identified. One of these was a relatively conventional louvered geometry, while the other involved a transpiration cooled configuration. A series of 10,000 cycle combustor rig tests on subscale MA956 and Hastelloy X combustor components showed no cracking, thereby confirming the beneficial effect of the segmented design on thermal fatigue capability. These tests also confirmed the superior oxidation and thermal distortion resistance of the ODS alloy. A hybrid PW2037 inner burner liner containing MA956 and Hastelloy X components was designed and constructed.

Henricks, R.J.; Sheffler, K.D.

1984-02-01T23:59:59.000Z

394

Design and Evaluation of a Net Zero Energy Low-Income Residential Housing Development in Lafayette, Colorado  

SciTech Connect (OSTI)

This abbreviated report outlines the lessons learned and sub-metered energy performance of an ultra low energy single family ranch home and duplex unit, called the Paradigm Pilot Project and presents the final design recommendations for a 153-unit net zero energy residential development called the Josephine Commons Project.

Dean, J.; Van Geet, O.; Simkus, S.; Eastment, M.

2012-04-01T23:59:59.000Z

395

Preliminary Systems Design Study assessment report. [Evaluation of using specific technologies, system concepts for treating the buried waste and the surrounding contaminated soil  

SciTech Connect (OSTI)

The System Design Study (SDS), part of the Waste Technology Development Department at the Idaho National Engineering Laboratory (INEL), examined techniques available for the remediation of hazardous and transuranic waste stored at the Radioactive Waste Management Complex's Subsurface Disposal Area at the INEL. Using specific technologies, system concepts for treating the buried waste and the surrounding contaminated soil were evaluated. Evaluation included implementability, effectiveness, and cost. The SDS resulted in the development of technology requirements including demonstration, testing, and evaluation activities needed for implementing each concept. This volume of the Systems Design Study contain four Appendixes that were part of the study. Appendix A is an EG G Idaho, Inc., report that represents a review and compilation of previous reports describing the wastes and quantities disposed in the Subsurface Disposal Area of the Idaho National Engineering Laboratory. Appendix B contains the process flowsheets considered in this study, but not selected for detailed analysis. Appendix C is a historical tabulation of radioactive waste incinerators. Appendix D lists Department of Energy facilities where cementation stabilization systems have been used.

Mayberry, J.L.; Feizollahi, F.; Del Signore, J.C.

1992-01-01T23:59:59.000Z

396

Design and Evaluation of a Net Zero Energy Low-Income Residential Housing Development in Lafayette, Colorado  

SciTech Connect (OSTI)

This report outlines the lessons learned and sub-metered energy performance of an ultra low energy single family ranch home and duplex unit, called the Paradigm Pilot Project and presents the final design recommendations for a 153-unit net zero energy residential development called the Josephine Commons Project. Affordable housing development authorities throughout the United States continually struggle to find the most cost-effective pathway to provide quality, durable, and sustainable housing. The challenge for these authorities is to achieve the mission of delivering affordable housing at the lowest cost per square foot in environments that may be rural, urban, suburban, or within a designated redevelopment district. With the challenges the U.S. faces regarding energy, the environmental impacts of consumer use of fossil fuels and the increased focus on reducing greenhouse gas emissions, housing authorities are pursuing the goal of constructing affordable, energy efficient and sustainable housing at the lowest life-cycle cost of ownership. This report outlines the lessons learned and sub-metered energy performance of an ultra-low-energy single family ranch home and duplex unit, called the Paradigm Pilot Project and presents the final design recommendations for a 153-unit net zero energy residential development called the Josephine Commons Project. In addition to describing the results of the performance monitoring from the pilot project, this paper describes the recommended design process of (1) setting performance goals for energy efficiency and renewable energy on a life-cycle cost basis, (2) using an integrated, whole building design approach, and (3) incorporating systems-built housing, a green jobs training program, and renewable energy technologies into a replicable high performance, low-income housing project development model.

Dean, J.; VanGeet, O.; Simkus, S.; Eastment, M.

2012-03-01T23:59:59.000Z

397

Integrating usability requirements that can be evaluated in design time into Model Driven Engineering of Web Information Systems  

Science Journals Connector (OSTI)

In recent years, Web Engineering development projects have grown increasingly complex for and critical to the smooth running of organizations. However, recent studies reveal that a high percentage of these projects fail to attain the quality parameters ... Keywords: Requirements metamodelling, Software quality, Usability evaluation, Web engineering

Fernando Molina; Ambrosio Toval

2009-12-01T23:59:59.000Z

398

Facility Design Manual Appalachian State University  

E-Print Network [OSTI]

at Charlotte Design and Construction Manual University of South Carolina Sustainable Design Guidelines US DOE & US Green Building Council (USGBC) Sustainable Building Technical Manual #12;A p p a l a c h i a nFacility Design Manual Appalachian State University #12;#12;© 2009 by Appalachian State University

Thaxton, Christopher S.

399

Preliminary results of an engineering and economic evaluation of Lurgi-Lentjes-Babcock`s circulating PFBC power plant design  

SciTech Connect (OSTI)

EPRI is currently completing a multiphased study to examine advanced power cycles based on fluidized-bed combustion. At the core of these studies have been examinations of the major PFBC systems being offered today. Previous studies have examined ABB-Carbon`s bubbling system and Pyropower`s circulating system PFBC, and Foster Wheeler`s advanced system. The current study being performed by Bechtel examines a circulating PFBC design offered by LLB. This paper presents preliminary performance and economic results for a nominal 90 MWe grassroots PFBC facility. The results appear to confirm that circulating PFBC systems offer lower capital costs, and therefore lower cost of electricity, than other coal-based power generation technologies. Performance at full load appears to be comparable to other PFBC technologies, although certain design features allow improved performance at reduced loads.

McKinsey, R.R. [Bechtel Corp., San Francisco, CA (United States); Wheeldon, J.M.; Brown, R.A. [Electric Power Research Inst., Palo Alto, CA (United States)

1996-12-31T23:59:59.000Z

400

The evaluation of micro-surfacing mixture design procedures and the effects of material variation on the test responses  

E-Print Network [OSTI]

. Precision Index Statements for Repeatability THE EFFECTS OF WATER, ADDITIVE AND MINERAL FILLER ON THE TEST RESPONSES OF THE MIXTURE DESIGN TESTS Page 45 63 63 66 General 66 Test Procedures 67 Analysis of Results Wet Cohesion Test (30 Minutes) Wet... 23. 30 minutes wet cohesion torque values against additive amounts with 8 percent water 84 FIGURE 24. 30 minutes wet cohesion torque values against mineral filler with 8 percent water 84 FIGURE 25. 30 minutes wet cohesion torque values against...

Andrews, Edward Mensah

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

An evaluation of the bioclimatic chart for choosing design strategies for a thermostatically-controlled residence in selected climates  

E-Print Network [OSTI]

...............................................................................24 2.3.2 Passive Solar Heating................................................................26 xi CHAPTER Page 2.3.3 Conventional Heating ...............................................................27 2.3.4 Humidification.......................49 4.2.1 Developing DOE-2 Input Files for Each Design Strategy........51 4.2.1.1 Lightweight House (Base Case).................................51 4.2.1.2 Lightweight House without Internal Loads................53 4.2.1.3 High...

Visitsak, Sopa

2009-05-15T23:59:59.000Z

402

Recommended guidelines for solid fuel use in cement plants  

SciTech Connect (OSTI)

Pulverized solid fuel use at cement plants in North America is universal and includes bituminous and sub-bituminous coal, petroleum coke, and any combination of these materials. Provided are guidelines for the safe use of pulverized solid fuel systems in cement plants, including discussion of the National Fire Protection Association and FM Global fire and explosion prevention standards. Addressed are fire and explosion hazards related to solid fuel use in the cement industry, fuel handling and fuel system descriptions, engineering design theory, kiln system operations, electrical equipment, instrumentation and safety interlock issues, maintenance and training, and a brief review of code issues. New technology on fire and explosion prevention including deflagration venting is also presented.

Young, G.L.; Jayaraman, H.; Tseng, H. (and others)

2007-07-01T23:59:59.000Z

403

APS Guideline for CAT/XOR Sector Orientation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

CAT/XSD Sector Orientation CAT/XSD Sector Orientation October 1, 1999 (Updated October 11, 2004) Introduction The orientation described in this guideline is designed to provide the basic information needed by new users to make safe and effective use of CAT/XSDÂ’s facilities at the APS. The CAT/XSD will also give appropriate parts of this orientation to visitors who are not expected to do hands-on work in CAT/XSD's facilities. Contents of the Orientation Part 1: APS Requirements CAT/XSD will ensure that prospective visitors are aware that they must: Register with the APS User Office and receive an appropriate safety orientation upon arrival and Never enter a controlled area unescorted. CAT/XSD will inform prospective users that they must: Contact the APS User Office prior to arrival for guidance on

404

Stress evaluation of the primary tank of a double-shell underground storage tank facility  

SciTech Connect (OSTI)

A facility called the Multi-Function Waste Tank Facility (MWTF) is being designed at the Department of Energy`s Hanford site. The MWTF is expected to be completed in 1998 and will consist of six underground double-shell waste storage tanks and associated systems. These tanks will provide safe and environmentally acceptable storage capacity to handle waste generated during single-shell and double-shell tank safety mitigation and remediation activities. This paper summarizes the analysis and qualification of the primary tank structure of the MWTF, as performed by ICF Kaiser Hanford during the latter phase of Title 1 (Preliminary) design. Both computer finite element analysis (FEA) and hand calculations methods based on the so-called Tank Seismic Experts Panel (TSEP) Guidelines were used to perform the analysis and evaluation. Based on the evaluations summarized in this paper, it is concluded that the primary tank structure of the MWTF satisfies the project design requirements. In addition, the hand calculations performed using the methodologies provided in the TSEP Guidelines demonstrate that, except for slosh height, the capacities exceed the demand. The design accounts for the adverse effect of the excessive slosh height demand, i.e., inadequate freeboard, by increasing the hydrodynamic wall and roof pressures appropriately, and designing the tank for such increased pressures.

Atalay, M.B. [ICF Kaiser Engineers, Inc., Oakland, CA (United States); Stine, M.D. [ICF Kaiser Hanford Co., Richland, WA (United States); Farnworth, S.K. [Westinghouse Hanford Co., Richland, WA (United States)

1994-12-01T23:59:59.000Z

405

Weatherization and Intergovernmental Program: Guidelines for Home Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Training Training Centers to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Training Centers on Facebook Tweet about Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Training Centers on Twitter Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Training Centers on Google Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Training Centers on Delicious Rank Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Training Centers on Digg Find More places to share Weatherization and Intergovernmental

406

Weatherization and Intergovernmental Program: Guidelines for Home Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Home Energy Home Energy Workers to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Home Energy Workers on Facebook Tweet about Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Home Energy Workers on Twitter Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Home Energy Workers on Google Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Home Energy Workers on Delicious Rank Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Home Energy Workers on Digg

407

Energy Department Launches Better Buildings Workforce Guidelines Project |  

Broader source: Energy.gov (indexed) [DOE]

Better Buildings Workforce Guidelines Better Buildings Workforce Guidelines Project Energy Department Launches Better Buildings Workforce Guidelines Project September 26, 2013 - 2:38pm Addthis The Energy Department today announced the Better Buildings Workforce Guidelines project to improve the quality and consistency of commercial building workforce training and certification programs for five key energy-related jobs: Energy Auditor, Commissioning Professional, Building/Stationary Engineer, Facility Manager, and Energy Manager. These voluntary workforce guidelines will support the Better Buildings Initiative goal of making commercial buildings 20% more energy efficient over the next 10 years, while helping businesses and communities save money by saving energy and creating new clean energy jobs across the country.

408

Weatherization and Intergovernmental Program: Guidelines for Home Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Homeowners Homeowners and Consumers to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Homeowners and Consumers on Facebook Tweet about Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Homeowners and Consumers on Twitter Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Homeowners and Consumers on Google Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Homeowners and Consumers on Delicious Rank Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Homeowners and Consumers on

409

Final Beamline Design Report  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Final Beamline Design Report Final Beamline Design Report Guidelines and Review Criteria (SCD 1.20.95) 6.0 Final Beamline Design Report (FDR) Overview The Final Beamline Design Report is part of the Advanced Photon Source (APS) beamline review process and should be planned for when approximately 90% of the total beamline design has been completed. Fifteen copies of the FDR are to be submitted to the APS Users Office. Approval of the Collaborative Access Team's (CAT) designs described in the report is required prior to installation of beamline components in the APS Experiment Hall. Components that have a long lead time for design or procurement can be reviewed separately from the remainder of the beamline, but enough information must be provided so that the reviewer can understand the

410

Design, production, and evaluation of a zircaloy-clad uranium target for an intense pulsed neutron source application  

SciTech Connect (OSTI)

The design of a Zircaloy-2-clad uranium alloy (450 ppm carbon, 250 ppm iron, 350 ppm silicon) target that can function as a pulsed spallation neutron source on interaction of a pulsed 500-MeV proton beam with the uranium nuclei is determined by consideration of irradiation damage, energy deposition, and thermal cycling effects in the target. The designed target is comprised of eight watercooled Zircaloy-2-clad uranium alloy disks, 10 cm in diameter and 2.7 cm thick operating at a maximum uranium alloy centerline temperature of 330/sup 0/C. The production of the Zircaloy-2-clad uranium alloy disks involves remelting of the cast uranium alloy by the consumable electrode technique and bonding of the Zircaloy-2 to the uranium alloy by subjecting the composite to an isostatic-helium pressure at 840/sup 0/C. The lifetime of the disks in the target before cracking of the Zircaloy-2 cladding owing to lowfrequency thermal cycling fatigue is estimated from stress calculations to be about 500 days. The results of thermal cycling tests on a disk tend to confirm the results of the stress calculations.

Loomis, B.A.; Fogle, G.L.; Gerber, S.B.; Thresh, H.R.

1981-12-01T23:59:59.000Z

411

Evaluation of critical materials for five advanced design photovoltaic cells with an assessment of indium and gallium  

SciTech Connect (OSTI)

The objective of this study is to identify potential material supply constraints due to the large-scale deployment of five advanced photovoltaic (PV) cell designs, and to suggest strategies to reduce the impacts of these production capacity limitations and potential future material shortages. This report presents the results of the screening of the five following advanced PV cell designs: polycrystalline silicon, amorphous silicon, cadmium sulfide/copper sulfide frontwall, polycrystalline gallium arsenide MIS, and advanced concentrator-500X. Each of these five cells is screened individually assuming that they first come online in 1991, and that 25 GWe of peak capacity is online by the year 2000. A second computer screening assumes that each cell first comes online in 1991 and that each cell has 5 GWe of peak capacity by the year 2000, so that the total online cpacity for the five cells is 25 GWe. Based on a review of the preliminary basline screening results, suggestions were made for varying such parameters as the layer thickness, cell production processes, etc. The resulting PV cell characterizations were then screened again by the CMAP computer code. Earlier DOE sponsored work on the assessment of critical materials in PV cells conclusively identtified indium and gallium as warranting further investigation as to their availability. Therefore, this report includes a discussion of the future availability of gallium and indium. (WHK)

Watts, R.L.; Gurwell, W.E.; Jamieson, W.M.; Long, L.W.; Pawlewicz, W.T.; Smith, S.A.; Teeter, R.R.

1980-05-01T23:59:59.000Z

412

Cyber Security Guidelines, Information Technology Division, ITD  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

BNL Cyber Security Guidelines BNL Cyber Security Guidelines Appropriate Use Unauthorized and Malicious Access and Actions Blatant Disregard for Laboratory Computer Security Privacy of Electronic Files, and E-MAIL Publishing & Accessing Information on Electronic Networks The Laboratory's main concerns are protecting data and systems critical to operations in pursuit of its mission. The Laboratory's Computer Security Plan covers Laboratory systems, whether on-site and connected directly to the Laboratory network, or on- or off-site and connected to the Laboratory network by the telephone system or other means. The procedures and rules described here cover these systems no matter who is the owner or the method of connection to the network. Laboratory employees and registered users are responsible for their own actions under the computer security policy, as well as for the actions of any person who they permit to access a Laboratory system.

413

WEIGHTED GUIDELINES PROFIT/FEE OBJECTIVE  

Broader source: Energy.gov (indexed) [DOE]

WEIGHTED GUIDELINES PROFIT/FEE OBJECTIVE WEIGHTED GUIDELINES PROFIT/FEE OBJECTIVE DOE F 4220.23 (06-95) U.S. DEPARTMENT OF ENERGY 1. CONTRACTOR IDENTIFICATION 2. TYPE OF ACQUISTION ACTION (REFER TO OFPP MANUAL, FEDERAL PROCUREMENT DATA SYSTEMS - PRODUCT AND SERVICE CODES. APRIL 1980) a. Name c. Street address b. Division (If any) d. City e. State f. Zip code a. SUPPLIES & EQUIPMENT b. RESEARCH & DEVELOPMENT c. SERVICES: (1) ARCHITECT-ENGINEER: (2) MANAGEMENT SERVICES: (3) MEDICAL: (4) OTHER (e.g., SUPPORT SERVICES) 3. ACQUISITION INFORMATION a. Purchasing Offices b. Contract type d. FY c. RFP/RFQ No. e. Contract No. PROFIT/FEE OBJECTIVE COMPUTATION PROFIT/FEE CONSIDERATIONS a. MEASUREMENT BASE b. PROFIT/FEE WEIGHT RANGES (%) c. ASSIGNED

414

Guidelines for Estimating Unmetered Industrial Water Use  

Broader source: Energy.gov (indexed) [DOE]

Guidelines for Guidelines for Estimating Unmetered Industrial Water Use Prepared for U.S. Department of Energy Federal Energy Management Program By Pacific Northwest National Laboratory Brian Boyd Revised September 2011 Source: Michael Kauffmann 2 Contacts Will Lintner Federal Energy Management Program 1000 Independence Ave., S.W. Washington, D.C. 20585-0121 Phone: (202) 586-3120 E-mail: William.Lintner@ee.doe.gov Brian Boyd Pacific Northwest National Laboratory 902 Battelle Boulevard Richland, WA 99352 Phone: (509) 371-6724 E-mail: Brian.Boyd@pnnl.gov 3 Acknowledgements This document was prepared by the Pacific Northwest National Laboratory (PNNL) on behalf of the Federal Energy Management Program. PNNL would like to thank the Federal Water Working Group of the Interagency Energy Management Task Force, which provided initial

415

Classified Reading Room Instructions/Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Classified Reading Room Instructions/Guidelines Classified Reading Room Instructions/Guidelines * Reading Room Points of Contact: Milesha Grier, (202) 586-8210, milesha.gier@nnsa.doe.gov Reading Room Location: DOE Forrestal Building, 1000 Independence Ave., Washington, D.C. Room 4A-045, 4 th Floor, "A" Corridor, Behind Glass Doors, dial 6-8210 Reading Room Availability: By Appointment - Reading Room will be available until RFP Closes except (12/5/11 thru 12/16/11, December 23, January 2, 2012 and January 16, 2012). Reading Room Hours: Morning, 9:00 a.m. - 11:30 a.m.; and Afternoon 1:00 p.m. - 3:30 p.m. Reading Room Will Accommodate: Up to 5-6 people * All personnel must: a. submit a formal Intent to Bid IAW Section L of the RFP, via email to: SEB1@doeal.gov

416

Guidelines for Estimating Unmetered Industrial Water Use  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Guidelines for Guidelines for Estimating Unmetered Industrial Water Use Prepared for U.S. Department of Energy Federal Energy Management Program By Pacific Northwest National Laboratory Brian Boyd Revised September 2011 Source: Michael Kauffmann 2 Contacts Will Lintner Federal Energy Management Program 1000 Independence Ave., S.W. Washington, D.C. 20585-0121 Phone: (202) 586-3120 E-mail: William.Lintner@ee.doe.gov Brian Boyd Pacific Northwest National Laboratory 902 Battelle Boulevard Richland, WA 99352 Phone: (509) 371-6724 E-mail: Brian.Boyd@pnnl.gov 3 Acknowledgements This document was prepared by the Pacific Northwest National Laboratory (PNNL) on behalf of the Federal Energy Management Program. PNNL would like to thank the Federal Water Working Group of the Interagency Energy Management Task Force, which provided initial

417

NREL: News Feature - Weatherization Work Guidelines Launched  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Weatherization Work Guidelines Launched Weatherization Work Guidelines Launched September 30, 2013 Photo of a man in a suit blowing insulation into an attic. Enlarge image William Stewart with Veterans Green Jobs blows cellulose insulation in the attic of a home A recent collaboration between the Energy Department, NREL, and the home energy performance industry is supporting the weatherization workforce with consistent on-the-job tools and accreditations that lead to better-defined career paths. Credit: Dennis Schroeder Getting up and going to work is hard enough every day. But add to your burden the need to remember every step of your job down to the smallest detail - and the fact that if you want to change careers, your lack of credentials might mean starting from scratch. These are the challenges

418

Guidelines for Estimating Unmetered Landscapting Water Use  

Broader source: Energy.gov (indexed) [DOE]

Guidelines for Estimating Guidelines for Estimating Unmetered Landscaping Water Use July 2010 i Summary Executive Order 13514 requires Federal agencies to develop a baseline for industrial, landscaping, and agricultural water use in fiscal year 2010. Measuring actual water use through flow meters is the best method to develop this baseline. But there are instances where Federal sites do not meter these applications, so developing a baseline will be problematic. Therefore the intent of this document is to assist Federal agencies in the baseline development by providing a methodology to calculate unmetered sources of landscaping water use utilizing engineering estimates. The document lays-out step by step instructions to estimate landscaping water using two alternative

419

Principles and guidelines for diversity in teamwork  

SciTech Connect (OSTI)

As part of Sandia`s Corporate Diversity Program, a Diversity Action Team was assembled to study the impact of diversity on teamwork. We reviewed the available literature on successful teaming, both with homogeneous (more alike than different) and heterogeneous teams. Although many principles and guidelines for successful homogeneous teams also apply to diverse teams, we believe that a document concentrating on diverse teams will be useful both for Sandians and for the outside world.

Berman, M.; Crespin, G.; Garcia, L.R.; Jansma, R.; Lovato, L.; Randall, G.; Sanchez, A.

1994-08-01T23:59:59.000Z

420

DOE-STD-1070-94; DOE Standard Guidelines for Evalation of Nuclear Facility Training Programs  

Broader source: Energy.gov (indexed) [DOE]

DOE-STD-1070-94 June 1994 DOE STANDARD GUIDELINES FOR EVALUATION OF NUCLEAR FACILITY TRAINING PROGRAMS U.S. Department of Energy FSC-6910 Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. This document has been reproduced directly from the best available copy. Available to DOE and DOE contractors from the Office of Scientific and Technical Information, P.O. Box 62, Oak Ridge, TN 37831; (615)576-8401. Available to the public from the U. S. Department of Commerce, Technology Administration, National Technical Information Service, Springfield, VA. 22161; (703)487-4650. Order No. DE94015536 DOE-STD-1070-94 iii FOREWORD The Department of Energy (DOE) Guidelines for Evaluation of Nuclear Facility Training

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Enahancing the Use of Coals by Gas Reburning - Sorbent Injection Volume 5 - Guideline Manual  

SciTech Connect (OSTI)

The purpose of the Guideline Manual is to provide recommendations for the application of combined gas reburning-sorbent injection (GR-SI) technologies to pre-NSPS boilers. The manual includes design recommendations, performance predictions, economic projections and comparisons with competing technologies. The report also includes an assessment of boiler impacts. Two full-scale demonstrations of gas reburning-sorbent injection form the basis of the Guideline Manual. Under the U.S. Department of Energy's Clean Coal Technology Program (Round 1), a project was completed to demonstrate control of boiler emissions that comprise acid rain precursors, specifically oxides of nitrogen (NOX) and sulfur dioxide (S02). Other project sponsors were the Gas Research Institute and the Illinois State Department of Commerce and Community Affairs. The project involved demonstrating the combined use of Gas Reburning and Sorbent Injection (GR-SI) to assess the air emissions reduction potential of these technologies.. Three potential coal-fired utility boiler host sites were evaluated: Illinois Power's tangentially-fired 71 MWe (net) Hennepin Unit W, City Water Light and Power's cyclone- fired 33 MWe (gross) Lakeside Unit #7, and Central Illinois Light Company's wall-fired 117 MWe (net) Edwards Unit #1. Commercial demonstrations were completed on the Hennepin and Lakeside Units. The Edwards Unit was removed from consideration for a site demonstration due to retrofit cost considerations. Gas Reburning (GR) controls air emissions of NOX. Natural gas is introduced into the furnace hot flue gas creating a reducing reburning zone to convert NOX to diatomic nitrogen (N,). Overfire air is injected into the furnace above the reburning zone to complete the combustion of the reducing (fuel) gases created in the reburning zone. Sorbent Injection (S1) consists of the injection of dry, calcium-based sorbents into furnace hot flue gas to achieve S02 capture. At each site where the techno!o@es were to be demonstrated, petiormance goals were set to achieve air emission reductions of 60 percent for NO. and 50 percent for SO2. These performance goals were exceeded during long term demonstration testing. For the tangentially fired unit, NOX emissions were reduced by 67.2% and S02 emissions by 52.6%. For the cyclone-fired unit, NOX emissions were reduced by 62.9% and SOZ emissions by 57.9%.

None

1998-09-01T23:59:59.000Z

422

Enhancing the Use of Coals by Gas Reburning - Sorbent Injection Volume 5 - Guideline Manual  

SciTech Connect (OSTI)

The purpose of the Guideline Manual is to provide recommendations for the application of combined gas reburning-sorbent injection (GR-SI) technologies to pre-NSPS boilers. The manual includes design recommendations, performance predictions, economic projections and comparisons with competing technologies. The report also includes an assessment of boiler impacts. Two full-scale demonstrations of gas reburning-sorbent injection form the basis of the Guideline Manual. Under the U.S. Department of Energy's Clean Coal Technology Program (Round 1), a project was completed to demonstrate control of boiler emissions that comprise acid rain precursors, specifically oxides of nitrogen (NOX) and sulfur dioxide (S02). Other project sponsors were the Gas Research Institute and the Illinois State Department of Commerce and Community Affairs. The project involved d,emonstrating the combined use of Gas Reburning and Sorbent Injection (GR-SI) to assess the air emissions reduction potential of these technologies.. Three potential coal-fired utility boiler host sites were evaluated: Illinois Power's tangentially-fired 71 MWe (net) Hennepin Unit #1, City Water Light and Power's cyclone- fired 33 MWe (gross) Lakeside Unit #7, and Central Illinois Light Company's wall-fired 117 MWe (net) Edwards Unit #1. Commercial demonstrations were completed on the Hennepin and Lakeside Units. The Edwards Unit was removed from consideration for a site demonstration due to retrofit cost considerations. Gas Reburning (GR) controls air emissions of NOX. Natural gas is introduced into the furnace hot flue gas creating a reducing reburning zone to convert NOX to diatomic nitrogen (N,). Overfire air is injected into the furnace above the reburning zone to complete the combustion of the reducing (fuel) gases created in the reburning zone. Sorbent Injection (S1) consists of the injection of dry, calcium-based sorbents into furnace hot flue gas to achieve S02 capture. `At each site where the technologies were to be demonstrated, performance goals were set to achieve air emission reductions of 60 percent for NOX and 50 percent for S02. These performance goals were exceeded during long term demonstration testing. For the tangentially fired unit, NO, emissions were reduced by 67.2?40 and SOZ emissions by 52.6Y0. For the cyclone-fired unit, NO, emissions were reduced by 62.9% and SOZ emissions by 57.9Y0.

None

1998-06-01T23:59:59.000Z

423

Measure Guideline: Air Sealing Mechanical Closets in Slab-On-Grade Homes  

SciTech Connect (OSTI)

This measure guideline describes covers two fundamental retrofit strategies for air sealing around air handling systems that are located within the living space in an enclosed closet: one in which all of the equipment is removed and being replaced, and a closet where the equipment is to remain and existing conditions are sealed. It includes the design and installation details necessary to effectively seal the air handler closet and central return system to maximize the efficiency and safety of the space conditioning system.

Dickson, B.

2012-02-01T23:59:59.000Z

424

Design Principles and Case Study Analysis for Low Impact Development Practices - Green Roofs, Rainwater Harvesting and Vegetated Swales.  

E-Print Network [OSTI]

??This thesis on Low Impact Development (LID) Practices provides design guidelines and principles for three important LID practices: green roofs, rainwater harvesting and bioswales. The… (more)

Ramesh, Shalini

2011-01-01T23:59:59.000Z

425

Umatilla Hatchery Monitoring and Evaluation, 1997-1998 Annual Report.  

SciTech Connect (OSTI)

This report summarizes monitoring and evaluation studies of salmonids reared at Umatilla Fish Hatchery (UFH) for the period November 1, 1997 to October 31, 1998. Studies at Umatilla Hatchery are designed to evaluate rearing of chinook salmon and steelhead in ''Michigan raceways''. Characteristics of Michigan raceways include high fish densities, rapid water turnover, oxygen supplementation, reuse of water, and baffles designed to reduce cleaning. Fish health at UFH and other facilities associated with the Umatilla program are intensively monitored and evaluated as part of the overall research project. Further, under the Integrated Hatchery Operations Team guidelines, specific requirements for fish health monitoring are mandatory and have become the responsibility of the fish health staff conducting studies at UFH. Additional studies include evaluations of sport fisheries in the Umatilla River and mass marking and straying of fall chinook salmon. Except for adult recovery data, an experiment designed to evaluate rearing subyearling fall chinook salmon in Michigan and Oregon raceways has been completed. We are currently in the second year of rearing subyearling fall chinook salmon at three densities. Experimental rearing of subyearling, fall release, and yearling spring chinook salmon, and steelhead has also been conducted. Although preliminary adult return data has been recovered, data on smolt-to-adult survival for all groups is incomplete. Conclusions in this report should be viewed as preliminary and used in conjunction with additional data as it becomes available.

Hayes, Michael C.; Brown, Kassandra A.; Waln, Karen (Oregon Department of Fish and Wildlife, Portland, OR)

1999-11-01T23:59:59.000Z

426

Design and evaluation of a device for measuring three-dimensional micromotions of press-fit femoral stem prostheses  

Science Journals Connector (OSTI)

Implant micromotion is considered to be a major factor in the loosening of cementless total hip replacements. Translational micromotion at the bone-implant interface generally occurs in all three spatial directions. Under physiological loading, the interfacial micromotion consists of a cyclic amplitude and changes in the mean, which, in the craniocaudal direction, represents subsidence of the prosthesis. Existing measurement strategies, which are based on dial gauges, extensometers, LVDTs, hall-effect transducers or strain gauge techniques provide information about only one component of the general three-dimensional micromovement. Moreover, in the majority of the studies, the data are difficult to interpret due to the measured motions being composed of interfacial micromotion and femoral strains. A new transducer was designed that allows the accurate measurement of all three isolated components of micromotion. An optoelectronic approach, based on silicon position-sensitive detectors (PSD) in combination with high precision mechanical parts, was chosen. To exclude thermodrifts during long-term testing, a thermistor was integrated in the sensor. Validation experiments on a precision positioning table indicated the high precision and resolution of the developed sensors. Furthermore, in-vitro tests on a standard press-fit prosthesis demonstrated the easy handling and reliability of the system.

D.W. Bühler; T.R. Oxland; L.-P. Nolte

1997-01-01T23:59:59.000Z

427

Finding Computed Diamonds in a Virtual Rough: Screening and Evaluation of Conformations and Energetics from Drug Discovery to Computational Enzyme Design  

E-Print Network [OSTI]

a) the EDGEScore distribution for design 1; b) the EDGEScorec) the EDGEScore distribution for design 2; d) the EDGEScorea) the EDGEScore distribution for design 1; b) the EDGEScore

Johnson, Scott Arne

2012-01-01T23:59:59.000Z

428

Post Quench Ductility Evaluation of Zircaloy-4 and Select Iron Alloys under Design Basis and Extended LOCA Conditions  

SciTech Connect (OSTI)

Oxidation experiments were conducted at 1200 C in flowing steam with tubing specimens of Zircaloy-4, 317, 347 stainless steels, and the commercial FeCrAl alloy APMT. The purpose was to determine the oxidation behavior and post quench ductility of these alloys under postulated loss-of-coolant accident conditions. The parabolic rate constant for Zircaloy-4 tubing samples at 1200 were determined to be k = 2.173 107 g2/cm4/s C, in excellent agreement with the Cathcart-Pawel correlation. The APMT alloy experienced the slowest oxidation rate among all materials examined in this work. The ductility of post quenched samples was evaluated by ring compression tests at 135 C. For Zircaloy-4, the ductile to brittle transition occurs at an equivalent cladding reacted (ECR) of 19.3%. SS-347 was still ductile after being oxidized for 2400 s (CP-ECR 50%), but the maximum load was reduced significantly owing to the metal layer thickness reduction. No ductility decrease was observed for the post-quenched APMT samples oxidized up to four hours.

Yan, Yong [ORNL] [ORNL; Keiser, James R [ORNL] [ORNL; Terrani, Kurt A [ORNL] [ORNL; Bell, Gary L [ORNL] [ORNL; Snead, Lance [ORNL] [ORNL

2014-01-01T23:59:59.000Z

429

Design, Synthesis, and Mechanistic Evaluation of Iron-Based Catalysis for Synthesis Gas Conversion to Fuels and Chemicals  

SciTech Connect (OSTI)

A detailed study of the catalyst composition, preparation and activation protocol of Fe-based catalysts for the Fischer-Tropsch Synthesis (FTS) have been carried out in this project. We have studied the effects of different promoters on the catalytic performance of Fe-based catalysts. Specifically, we have focused on how their sequence of addition dramatically influences the performance of these materials in the Fischer-Tropsch synthesis. The resulting procedures have been optimized to improve further upon the already unprecedented rates and C{sub 5+} selectivities of the Fe-based catalysts that we have developed as part of this project. Selectivity to C{sub 5+} hydrocarbon was close to 90 % (CO{sub 2}-free basis) and CO conversion rate was about 6.7 mol h{sup -1} g-at Fe{sup -1} at 2.14 MPa, 508 K and with substoichiometric synthesis gas; these rates were larger than any reported previously for Fe-based FTS catalysts at these conditions. We also tested the stability of Fe-based catalysts during FTS reaction (10 days); as a result, the high hydrocarbon formation rates were maintained during 10 days, though the gradual deactivation was observed. Our investigation has also focused on the evaluation of Fe-based catalysts with hydrogen-poor synthesis gas streams (H{sub 2}/CO=1). We have observed that the Fe-based catalysts prepared in this project display also a high hydrocarbon synthesis rate with substoichiometric synthesis gas (H{sub 2}/CO=1) stream, which is a less desirable reactant mixture than stoichiometric synthesis gas (H{sub 2}/CO=2). We have improved the catalyst preparation protocols and achieved the highest FTS reaction rates and selectivities so far reported at the low temperatures required for selectivity and stability. Also, we have characterized the catalyst structural change and active phases formed, and their catalytic behavior during the activation process to evaluate their influences on FTS reaction. The efforts of this project led to (i) structural evolution of Fe-Zn oxide promoted with K and Cu, and (ii) evaluation of hydrocarbon and CH{sub 4} formation rates during activation procedures at various temperature and H{sub 2}/CO ratios. On the basis of the obtained results, we suggest that lower reactor temperature can be sufficient to activate catalysts and lead to the high FTS performance. In this project, we have also carried out a detailed kinetic and mechanistic study of the Fischer-Tropsch Synthesis with Fe-based catalysts. We have proposed a reaction mechanism with two CO activation pathways: unassisted and H-assisted. Both routes lead to the formation of the same surface monomers (CH{sub 2}). However, the oxygen removal mechanism is different. In the H-assisted route, oxygen is removed exclusively as water, while oxygen is rejected as carbon dioxide in the unassisted CO dissociation. The validity of the mechanism here proposed has been found to be in agreement with the experimental observation and with theoretical calculations over a Fe(110) surface. Also, we have studied the validity of the mechanism that we propose by analyzing the H{sub 2}/D{sub 2} kinetic isotope effect (r{sub H}/r{sub D}) over a conventional iron-based Fischer-Tropsch catalyst Fe-Zn-K-Cu. We have observed experimentally that the use of D{sub 2} instead of H{sub 2} leads to higher hydrocarbons formation rates (inverse kinetic isotopic effect). On the contrary, primary carbon dioxide formation is not influenced. These experimental observations can be explained by two CO activation pathways. We have also explored the catalytic performance of Co-based catalysts prepared by using inverse micelles techniques. We have studied several methods in order to terminate the silanol groups on SiO{sub 2} support including impregnation, urea homogeneous deposition-precipitation, or zirconium (IV) ethoxide titration. Although hydroxyl groups on the SiO{sub 2} surface are difficult to be stoichiometrically titrated by ZrO{sub 2}, a requirement to prevent the formation of strongly-interacting Co oxide species on SiO{sub 2}, modification of ZrO{

Enrique Iglesia; Akio Ishikawa; Manual Ojeda; Nan Yao

2007-09-30T23:59:59.000Z

430

World Bank Good Practice Guidelines: Financial Analysis of Revenue  

Open Energy Info (EERE)

Practice Guidelines: Financial Analysis of Revenue Practice Guidelines: Financial Analysis of Revenue Generating-Entities (Redirected from General Renewable Energy-Economic and Financial Analysis) Jump to: navigation, search Tool Summary Name: World Bank Good Practice Guidelines: Financial Analysis of Revenue Generating-Entities Agency/Company /Organization: World Bank Topics: Finance Resource Type: Guide/manual Website: siteresources.worldbank.org/INTRANETFINANCIALMGMT/Resources/FMB-Notes/ References: World Bank Good Practice Guidelines: Financial Analysis of Revenue Generating-Entities[1] References ↑ "World Bank Good Practice Guidelines: Financial Analysis of Revenue Generating-Entities" Retrieved from "http://en.openei.org/w/index.php?title=World_Bank_Good_Practice_Guidelines:_Financial_Analysis_of_Revenue_Generating-Entities&oldid=329414

431

Guidelines for the Protection of Surface and Groundwater Resources During  

Open Energy Info (EERE)

Guidelines for the Protection of Surface and Groundwater Resources During Guidelines for the Protection of Surface and Groundwater Resources During Exploration Drilling Jump to: navigation, search OpenEI Reference LibraryAdd to library Report: Guidelines for the Protection of Surface and Groundwater Resources During Exploration Drilling Author Government of Western Australia Organization Department of Mines and Petroleum Published N/A, 2002 DOI Not Provided Check for DOI availability: http://crossref.org Online Internet link for Guidelines for the Protection of Surface and Groundwater Resources During Exploration Drilling Citation Government of Western Australia (Department of Mines and Petroleum). 2002. Guidelines for the Protection of Surface and Groundwater Resources During Exploration Drilling. N\A: N/A. Retrieved from "http://en.openei.org/w/index.php?title=Guidelines_for_the_Protection_of_Surface_and_Groundwater_Resources_During_Exploration_Drilling&oldid=686528"

432

Guidelines for Home Energy Professionals | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Buildings » Guidelines for Home Energy Professionals Residential Buildings » Guidelines for Home Energy Professionals Guidelines for Home Energy Professionals The U.S. Department of Energy's Guidelines for Home Energy Professionals project fosters the growth of a high quality residential energy upgrade industry and a skilled and credentialed workforce. The project has three components: Guidelines for quality work define the minimum requirements for high quality work and the conditions necessary to achieve the desired outcomes of a given energy upgrade, such as installation of attic insulation and sealing windows and doors. Guidelines for effective training catalog the key tasks an Energy Auditor, Retrofit Installer Technician, Crew Leader, or Quality Control Inspector performs to complete a given job and the knowledge, skills, and

433

FAO-Environmental Impact Statement Guidelines | Open Energy Information  

Open Energy Info (EERE)

FAO-Environmental Impact Statement Guidelines FAO-Environmental Impact Statement Guidelines Jump to: navigation, search Tool Summary Name: FAO-Environmental Impact Statement Guidelines Agency/Company /Organization: Food and Agriculture Organization of the United Nations Sector: Land Focus Area: Agriculture, Forestry Topics: Co-benefits assessment, - Environmental and Biodiversity Resource Type: Guide/manual Website: www.fao.org/docrep/014/am862e/am862e00.pdf References: FAO-Environmental Impact Statement Guidelines[1] "This publication provides guidelines for all FAO units (headquarters departments and offices, as well as decentralized offices) to undertake environmental impact assessments (EIA) of field projects. The use of these guidelines apply to all FAO field projects and activities, as further

434

Effectiveness of guidelines for retiming signalized diamond interchanges  

E-Print Network [OSTI]

OF SCIENCE May 1991 Major Subject: Civil Engineering EFFECTIVENESS OF GUIDELINES FOR RETIMING SIGNALIZED DIAMOND INTERCHANGES A Thesis by YVONNE DENISE IRVINE Approved as to style and content by: Daniel B. Fambro (Chair of Committee) Thomas Urbanik.... For the diamond interchange test, the participants were randomly assigned to two groups: the control group with no guidelines as reference or the second group, with the guidelines. The average scores on the diamond interchange test were compared using analysis...

Irvine, Yvonne Denise

1991-01-01T23:59:59.000Z

435

Solar industry advertising guidelines. Task III  

SciTech Connect (OSTI)

The purpose of these guidelines is to acquaint SEIA members with basic principles of Federal Trade Commission (FTC) law related to advertising and sales representations in order to assist SEIA members in insuring that their advertising is fair and accurate when assessed against FTC standards, thereby avoiding potentially costly FTC action. The following are discussed: the nature of advertising, when is an advertisement deceptive, advertising of product certification and testing results, substantiation for advertising claims, advertising of tax credits, warranty advertising, potential liabilities under the FTC Act, and recommendations for avoiding FTC action. (MHR)

Hostetler, J.S.

1981-09-01T23:59:59.000Z

436

Sandia Software Guidelines, Volume 2. Documentation  

SciTech Connect (OSTI)

This volume is one in a series of Sandia Software Guidelines intended for use in producing quality software within Sandia National Laboratories. In consonance with the IEEE Standards for software documentation, this volume provides guidance in the selection of an adequate document set for a software project and example formats for many types of software documentation. A tutorial on life cycle documentation is also provided. Extended document thematic outlines and working examples of software documents are available on electronic media as an extension of this volume.

NONE

1995-09-01T23:59:59.000Z

437

Weatherization and Intergovernmental Program: Guidelines for Home Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Utilities Utilities and Efficiency Program Administrators to someone by E-mail Share Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Utilities and Efficiency Program Administrators on Facebook Tweet about Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Utilities and Efficiency Program Administrators on Twitter Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Utilities and Efficiency Program Administrators on Google Bookmark Weatherization and Intergovernmental Program: Guidelines for Home Energy Professionals Project: Benefits for Utilities and Efficiency Program Administrators on Delicious

438

Quality Work Plan Guidelines and Standards Requirement | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Work Plan Guidelines and Standards Requirement an icon of a page The Weatherization Assistance Program's (WAP) comprehensive Quality Work Plan establishes a benchmark for quality...

439

CALIFORNIA GUIDELINES FOR REDUCING IMPACTS TO BIRDS AND BATS FROM  

E-Print Network [OSTI]

, bat fatality, bat injury, bat mortality, bird fatality, bird injury, carcass count, Migratory Bird Treaty Act, rotorswept area, wind energy, wind siting guidelines, wind turbines. #12; #12; i

440

Weatherization and Workforce Guidelines for Home Energy Upgrades...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

for Home Energy Upgrades Fact Sheet Weatherization and Workforce Guidelines for Home Energy Upgrades Fact Sheet This fact sheet provides essential information about the 2011...

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Guidelines for Low Emission Land use Planning | Open Energy Informatio...  

Open Energy Info (EERE)

Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Guidelines for Low Emission Land use Planning AgencyCompany Organization: USAID LEAF Sector: Climate, Land...

442

FY14 Guidelines for Brownfields Cleanup Grants | Open Energy...  

Open Energy Info (EERE)

Abstract These guidelines provide instruction on obtaining a brownfields cleanup grant. Author EPA Published EPA, 2014 DOI Not Provided Check for DOI availability: http:...

443

Work Plan Guidelines and Standards Requirement | Department of...  

Energy Savers [EERE]

Assistance Program's (WAP) comprehensive Quality Work Plan establishes a benchmark for quality home energy upgrades. The plan includes a Guidelines and Standards requirement...

444

Changes to Geothermal Reporting Code and Guidelines on Company...  

Open Energy Info (EERE)

Company Reporting Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Paper: Changes to Geothermal Reporting Code and Guidelines on Company Reporting...

445

Guidelines for Applicants for Energy Facility Site Certificates...  

Open Energy Info (EERE)

search OpenEI Reference LibraryAdd to library PermittingRegulatory Guidance - GuideHandbook: Guidelines for Applicants for Energy Facility Site CertificatesPermittingRegulatory...

446

Guidelines for Provision and Interchange of Geothermal Data Assets  

Broader source: Energy.gov [DOE]

This document presents guidelines related to provision and interchange of data assets in the context of the National Geothermal Data System.

447

Guidelines for Home Energy Professionals Project: Benefits for...  

Broader source: Energy.gov (indexed) [DOE]

Utilities and Efficiency Program Administrators Guidelines for Home Energy Professionals Project: Benefits for Utilities and Efficiency Program Administrators Photo of a...

448

Thermodynamic Guidelines for the Prediction of Hydrogen Storage...  

Broader source: Energy.gov (indexed) [DOE]

Thermodynamic guidelines for the prediction of hydrogen storage reactions and their application to destabilized hydride mixtures Hydrogen Storage & Nanoscale Modeling Group Ford...

449

Guidelines for Home Energy Professionals Project Updates | Department...  

Energy Savers [EERE]

Announcements Download archived monthly project announcements on the Guidelines for Home Energy Professionals Project. Multifamily Content Now Available via the SWS Tool Request...

450

Draft Revised Guidelines for Implementing Executive Order 11988, "Floodplain Management"  

Broader source: Energy.gov [DOE]

The Federal Emergency Management Agency published the draft “Revised Guidelines for Implementing Executive Order 11988, Floodplain Management” for public review and comment on January 30, 2015.

451

Quality Guidelines for Energy System Studies: Detailed Coal Specificat...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Laboratory Office of Program Performance and Benefits 2 January 2012 Detailed Coal Specifications Quality Guidelines for Energy System Studies Disclaimer This report was...

452

About the Guidelines for Home Energy Professionals Project |...  

Broader source: Energy.gov (indexed) [DOE]

About the Office Weatherization Assistance Program Where to Apply for Assistance What is Weatherization Goals & Metrics Pilot Projects Success Stories Guidelines for Home Energy...

453

Weatherization & Intergovernmental Program: Guidelines for Home Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Guidelines for Home Energy Professionals Guidelines for Home Energy Professionals Sign Up for Project Updates The U.S. Department of Energy (DOE) Guidelines for Home Energy Professionals project helps establish a national residential energy upgrade industry and a skilled and credentialed workforce. The project creates standard work specifications, advanced professional certifications for workers, and accredited training programs. The Guidelines for Home Energy Professionals project is a collaboration between DOE and the home energy performance industry. Learn more about the project and find project updates. Information on: Standard Work Specifications Industry-approved work specifications define acceptable outcomes for weatherization and home energy upgrades. Home Energy Professional Certifications

454

Quality Guidelines for Energy System Studies: Fuel Pricing  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

11212 National Energy Technology Laboratory Office of Program Performance and Benefits 2 Fuel Prices for Selected Feedstocks in NETL Studies Quality Guidelines for Energy System...

455

Developing Integrated National Design Standards for Offshore Wind Plants  

Broader source: Energy.gov [DOE]

The DOE Wind Program and the National Renewable Energy Laboratory recently published a report that summarizes the regulations, standards, and guidelines for the design and operation of offshore wind projects in the United States.

456

Measure Guideline: Guide to Attic Air Sealing  

SciTech Connect (OSTI)

The Guide to Attic Air Sealing was completed in 2010 and although not in the standard Measure Guideline format, is intended to be a Measure Guideline on Attic Air Sealing. The guide was reviewed during two industry stakeholders meetings held on December 18th, 2009 and January 15th, 2010, and modified based on the comments received. Please do not make comments on the Building America format of this document. The purpose of the Guide to Attic Air Sealing is to provide information and recommendations for the preparation work necessary prior to adding attic insulation. Even though the purpose of this guide is to save energy - health, safety and durability should not be compromised by energy efficiency. Accordingly, combustion safety and ventilation for indoor air quality are addressed first. Durability and attic ventilation then follow. Finally, to maximize energy savings, air sealing is completed prior to insulating. The guide is intended for home remodelers, builders, insulation contractors, mechanical contractors, general contractors who have previously done remodeling and homeowners as a guide to the work that needs to be done.

Lstiburek, J.

2014-09-01T23:59:59.000Z

457

Appendix C: DOE Super-ESPC Project Acceptance Guidelines and Checklist  

Broader source: Energy.gov (indexed) [DOE]

Guidelines, Checklist, and Contract Clauses for Government Acceptance Guidelines, Checklist, and Contract Clauses for Government Acceptance of DOE Super-ESPC Projects  ECM Installation: All ECMs are installed in accordance with plans, specifications, standards, and other contract documents (sometimes by the Contractor, often by a subcontractor and always over a period of months).  Inspection, start-up, testing and commissioning. All ECMs are inspected, brought on line, tested, and commissioned interactively with all related Government-owned or Contractor-installed ECMs. Again, the ECMs should be operating in accordance with the design, plans, specifications, standards and other contract documents and manufacturer's recommendations. Individual ECMs may go through start-up and testing, but all interrelated

458

STUDENT ADVISOR GUIDELINES PROPOSAL: ASSESSMENTS OF AND PROPOSED CHANGES  

E-Print Network [OSTI]

STUDENT ADVISOR GUIDELINES PROPOSAL: ASSESSMENTS OF AND PROPOSED CHANGES TO THE NJIT ADVISING PROCESS NEW JERSEY INSTITUTE OF TECHNOLOGY STUDENT SENATE STUDENT ADVISOR GUIDELINES COMMITTEE DECEMBER of NJIT as a whole. -2- #12;I. Students' Views of Advisors Obligations These are the recommendations

Bieber, Michael

459

Computer Replacement Guidelines Environmental Health and Safety, Stanford University  

E-Print Network [OSTI]

Computer Replacement Guidelines Environmental Health and Safety, Stanford University 17 November 2005 This document describes the guidelines for replacing laptop and desktop computers at Environmental Health and Safety. PC laptop and desktop computers will be replaced a) on an ongoing basis where

460

University Policy Process Style Guidelines for University Policy Documents  

E-Print Network [OSTI]

University Policy Process Style Guidelines for University Policy Documents 1 S:\\4every1\\Policy\\Univ Policy Improvement\\Final Docs\\Style Guidelines-UPP.docx Policy Name Do not include "Policy" or "Policy on specific applications such as "anyone operating university owned or operated vehicles". POLICY (required

Jones, Michelle

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

SEED Grant Guidelines Revised February 2014 UNBC RESEARCH SEED GRANT  

E-Print Network [OSTI]

SEED Grant Guidelines � Revised February 2014 UNBC RESEARCH SEED GRANT GUIDELINES OBJECTIVE OF APPLICATIONS 1.1 Quality of proposal. 1.2 Likelihood of the Seed Grant leading to external funding. 1 external sources. A member's term must not end before the seed grant ends. 2.2 Faculty in their first year

Northern British Columbia, University of

462

Guidelines for Graduate Student Advising and Mentoring Relationships  

E-Print Network [OSTI]

/scholarship. Quality research/scholarship is also fundamentally important in establishing strong professional in 2003-04.The Research MentoringTask Force, chaired by the late Hans Kende, MSU's first member to these Guidelines is a requirement for each graduate program handbook at MSU. The purpose of the Guidelines

463

PAGE 2 | Guideline for the Management Of Acute  

E-Print Network [OSTI]

PAGE 2 | Guideline for the Management Of Acute And Chronic Pain In Sickle Cell Disease. American Societies PAGE 5 | Editorial Comment Current Guidelines For Sickle Cell Disease: Management Of Acute Of Acute And Chronic Pain In Sickle Cell Disease. American Pain Society. PAGE 4 | The Management of Sickle

464

Brand Guidelines Northwestern University Feinberg School of Medicine  

E-Print Network [OSTI]

, the repetition of messages and visuals serves to solidify a brand's image. For Feinberg, these messagesBrand Guidelines Northwestern University Feinberg School of Medicine Published February 9, 2010 djfhakjd ExitForwardBack #12;1 Northwestern University Feinberg School of Medicine Brand Guidelines Story

Engman, David M.

465

Building Technologies Office: Guidelines for Home Energy Professionals  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Guidelines for Home Energy Professionals Guidelines for Home Energy Professionals The U.S. Department of Energy's Guidelines for Home Energy Professionals project fosters the growth of a high quality residential energy upgrade industry and a skilled and credentialed workforce. The project has three components: Guidelines for quality work define the minimum requirements for high quality work and the conditions necessary to achieve the desired outcomes of a given energy upgrade, such as installation of attic insulation and sealing windows and doors. Guidelines for effective training catalog the key tasks an Energy Auditor, Retrofit Installer Technician, Crew Leader, or Quality Control Inspector performs to complete a given job and the knowledge, skills, and abilities (KSAs) the worker should possess to perform those tasks adequately.

466

Industrial Energy Audit Guidebook: Guidelines for Conducting an Energy  

Open Energy Info (EERE)

Industrial Energy Audit Guidebook: Guidelines for Conducting an Energy Industrial Energy Audit Guidebook: Guidelines for Conducting an Energy Audit in Industrial Facilities Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Industrial Energy Audit Guidebook: Guidelines for Conducting an Energy Audit in Industrial Facilities Agency/Company /Organization: Lawrence Berkeley National Laboratory Sector: Energy Focus Area: Energy Efficiency, Industry Resource Type: Guide/manual Website: china.lbl.gov/sites/china.lbl.gov/files/LBNL-3991E.Industrial%20Energy Industrial Energy Audit Guidebook: Guidelines for Conducting an Energy Audit in Industrial Facilities Screenshot References: Industrial Energy Audit Guidebook[1] "This guidebook provides guidelines for energy auditors regarding the key elements for preparing for an energy audit, conducting an inventory and

467

Department of Energy Information Quality Guidelines | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

About this site » Department of Energy Information Quality About this site » Department of Energy Information Quality Guidelines Department of Energy Information Quality Guidelines Information Quality The Department of Energy's Information Quality Guidelines are developed in accordance with Section 515, Treasury and General Government Appropriations Act (Pub.L. 106-554). The law directed the Office of Management and Budget (OMB) to issue government-wide guidelines that "provide policy and procedural guidance to Federal Agencies for ensuring and maximizing the quality, objectivity, utility, and integrity of information (including statistical information) disseminated by Federal Agencies." OMB guidelines, published in the Federal Register on February 22, 2002 (67 FR 8452), direct agencies to issue their own implementing

468

Cybersecurity Risk Management Process (RMP) Guideline - Final (May 2012) |  

Broader source: Energy.gov (indexed) [DOE]

Cybersecurity Risk Management Process (RMP) Guideline - Final (May Cybersecurity Risk Management Process (RMP) Guideline - Final (May 2012) Cybersecurity Risk Management Process (RMP) Guideline - Final (May 2012) This electricity subsector cybersecurity Risk Management Process (RMP) guideline was developed by the Department of Energy, in collaboration with the National Institute of Standards and Technology (NIST) and the North American Electric Reliability Corporation (NERC). The RMP is written with the goal of enabling organizations- regardless of size or organizational or governance structure-to apply effective and efficient risk management processes and tailor them to meet their organizational requirements. This guideline may be used to implement a new cybersecurity program within an organization or to build upon an organization's existing internal

469

Cybersecurity Risk Management Process (RMP) Guideline - Final (May 2012) |  

Broader source: Energy.gov (indexed) [DOE]

Cybersecurity Risk Management Process (RMP) Guideline - Final (May Cybersecurity Risk Management Process (RMP) Guideline - Final (May 2012) Cybersecurity Risk Management Process (RMP) Guideline - Final (May 2012) This electricity subsector cybersecurity Risk Management Process (RMP) guideline was developed by the Department of Energy, in collaboration with the National Institute of Standards and Technology (NIST) and the North American Electric Reliability Corporation (NERC). The RMP is written with the goal of enabling organizations- regardless of size or organizational or governance structure-to apply effective and efficient risk management processes and tailor them to meet their organizational requirements. This guideline may be used to implement a new cybersecurity program within an organization or to build upon an organization's existing internal

470

ARM - Engineering Change Request & Engineering Change Order Guidelines  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Change Request & Change Request & Engineering Change Order Guidelines Page Contents: Guideline for Starting a Request for a New ARM Product, Capability, or Functionality Engineering Task Tracking Tool Tracking Capabilities Getting Closure, the Baseline Change Request Glossary Engineering Change Request & Engineering Change Order Guidelines Requesting Engineered Products and Services in ARM Guideline for Starting a Request for a New ARM Product, Capability, or Functionality The purpose of this guideline is to establish a method that members of the ARM Infrastructure team may use to submit requests for products and services from the ARM Engineering Group. The concept of "new product, capability, or functionality" refers to the idea that requests the ARM Infrastructure Team to make to the Engineering Group that will ultimately

471

IREC Renewable Energy Training Best Practices and Recommended Guidelines |  

Open Energy Info (EERE)

IREC Renewable Energy Training Best Practices and Recommended Guidelines IREC Renewable Energy Training Best Practices and Recommended Guidelines Jump to: navigation, search Tool Summary Name: IREC Renewable Energy Training Best Practices and Recommended Guidelines Agency/Company /Organization: Interstate Renewable Energy Council Sector: Energy Focus Area: Renewable Energy Resource Type: Guide/manual, Training materials, Lessons learned/best practices Website: irecusa.org/wp-content/uploads/2009/10/BestPracticesFormatted2010Final IREC Renewable Energy Training Best Practices and Recommended Guidelines Screenshot References: IREC Renewable Energy Training Best Practices and Recommended Guidelines[1] Overview "The framework for creating a strong workforce for the renewable energy industries is built on a multiprong approach that connects labor market

472

New Draft of Cybersecurity Risk Management Process (RMP) Guideline Now  

Broader source: Energy.gov (indexed) [DOE]

Draft of Cybersecurity Risk Management Process (RMP) Guideline Draft of Cybersecurity Risk Management Process (RMP) Guideline Now Available for Public Comment (March 2012) New Draft of Cybersecurity Risk Management Process (RMP) Guideline Now Available for Public Comment (March 2012) March 1, 2012 - 3:26pm Addthis The Department of Energy, in collaboration with the National Institute of Standards and Technology (NIST) and the North American Electric Reliability Corporation (NERC), has released a second draft of the Electricity Subsector Cybersecurity Risk Management Process (RMP) guideline for public comment. This new draft, which will be the last opportunity for public comment prior to final publication, incorporates input submitted by the electric sector during the first public comment period. Many of the submitted comments suggested that the guideline:

473

Best Practices Guide for Energy-Efficient Data Center Design: Revised March 2011 (Brochure)  

SciTech Connect (OSTI)

This guide provides an overview of best practices for energy-efficient data center design which spans the categories of Information Technology (IT) systems and their environmental conditions, data center air management, cooling and electrical systems, on-site generation, and heat recovery. IT system energy efficiency and environmental conditions are presented first because measures taken in these areas have a cascading effect of secondary energy savings for the mechanical and electrical systems. This guide concludes with a section on metrics and benchmarking values by which a data center and its systems energy efficiency can be evaluated. No design guide can offer 'the most energy-efficient' data center design but the guidelines that follow offer suggestions that provide efficiency benefits for a wide variety of data center scenarios.

Not Available

2011-03-01T23:59:59.000Z

474

Illness and Injury Surveillance Program Guidelines  

Broader source: Energy.gov (indexed) [DOE]

DOE-STD-1190-2007 DOE-STD-1190-2007 DOE STANDARD ILLNESS AND INJURY SURVEILLANCE PROGRAM GUIDELINES U.S. Department of Energy AREA OCSH Washington, D.C. 20585 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. NOT MEASUREMENT SENSITIVE DOE-STD-1190-2007 Available on the Department of Energy Technical Standards Program Web site at http://tis.eh.doe.gov/techstds/ DOE-STD-1190-2007 Foreword 1. Use of this standard is not mandatory. Users should review the document and determine if it meets their purpose. 2. Comments (recommendations, additions, and deletions) that may be of use in improving this document should be addressed to: U.S. Department of Energy, Office of Health, c/o Dr. Cliff

475

GUIDELINES FOR THE USE OF TENTS The following guidelines are based on the requirements of the California Fire Code,  

E-Print Network [OSTI]

. The following calculation will determine the occupant load with tables and chairs: net square footage of tentGUIDELINES FOR THE USE OF TENTS The following guidelines are based on the requirements from the material manufacturer or supplier. Exits and Occupant Load for Enclosed Tents · Tents

de Lijser, Peter

476

C:\\Documents and Settings\\rpriesmeyer\\My Documents\\Word\\FAMIS Purchasing Guidelines.doc FAMIS Purchasing Guidelines  

E-Print Network [OSTI]

in the administrative offices. The most obvious change will be in the way document numbers (the new purchase orderC:\\Documents and Settings\\rpriesmeyer\\My Documents\\Word\\FAMIS Purchasing Guidelines.doc FAMIS Purchasing Guidelines We are now utilizing the FAMIS (Financial Accounting Information Systems) State

Behmer, Spencer T.

477

Interim radiological safety standards and evaluation procedures for subseabed high-level waste disposal  

SciTech Connect (OSTI)

The Seabed Disposal Project (SDP) was evaluating the technical feasibility of high-level nuclear waste disposal in deep ocean sediments. Working standards were needed for risk assessments, evaluation of alternative designs, sensitivity studies, and conceptual design guidelines. This report completes a three part program to develop radiological standards for the feasibility phase of the SDP. The characteristics of subseabed disposal and how they affect the selection of standards are discussed. General radiological protection standards are reviewed, along with some new methods, and a systematic approach to developing standards is presented. The selected interim radiological standards for the SDP and the reasons for their selection are given. These standards have no legal or regulatory status and will be replaced or modified by regulatory agencies if subseabed disposal is implemented. 56 refs., 29 figs., 15 tabs.

Klett, R.D.

1997-06-01T23:59:59.000Z

478

Collect Available Creep-Fatigue Data and Study Existing Creep-Fatigue Evaluation Procedures for Grade 91 and Hastelloy XR  

SciTech Connect (OSTI)

This report describes the results of investigation on Task 5 of DOE/ASME Materials Project based on a contract between ASME Standards Technology, LLC (ASME ST-LLC) and Japan Atomic Energy Agency (JAEA). Task 5 is to collect available creep-fatigue data and study existing creep-fatigue evaluation procedures for Grade 91 steel and Hastelloy XR. Part I of this report is devoted to Grade 91 steel. Existing creep-fatigue data were collected (Appendix A) and analyzed from the viewpoints of establishing a creep-fatigue procedure for VHTR design. A fair amount of creep-fatigue data has been obtained and creep-fatigue phenomena have been clarified to develop design standards mainly for fast breeder reactors. Following this, existing creep-fatigue procedures were studied and it was clarified that the creep-fatigue evaluation procedure of the ASME-NH has a lot of conservatisms and they were analyzed in detail from the viewpoints of the evaluation of creep damage of material. Based on the above studies, suggestions to improve the ASME-NH procedure along with necessary research and development items were presented. Part II of this report is devoted to Hastelloy XR. Existing creep-fatigue data used for development of the high temperature structural design guideline for High Temperature Gas-cooled Reactor (HTGR) were collected. Creep-fatigue evaluation procedure in the design guideline and its application to design of the intermediate heat exchanger (IHX) for High Temperature Engineering Test Reactor (HTTR) was described. Finally, some necessary research and development items in relation to creep-fatigue evaluation for Gen IV and VHTR reactors were presented.

Tai Asayama; Yukio Tachibana

2007-09-30T23:59:59.000Z

479

Seismic Design Expectations Report  

Broader source: Energy.gov [DOE]

The Seismic Design Expectations Report (SDER) is a tool that assists DOE federal project review teams in evaluating the technical sufficiency of the project seismic design activities prior to...

480

E-Print Network 3.0 - accident management guidelines Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

results for: accident management guidelines Page: << < 1 2 3 4 5 > >> 1 Emergency Procedures Guidelines Student Group Travel Off-Campus Activity Summary: Emergency Procedures...

Note: This page contains sample records for the topic "design evaluation guidelines" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Service Oriented Architecture & Web Services: Guidelines for Migrating from Legacy Systems and Financial Consideration.  

E-Print Network [OSTI]

??The purpose of this study is to present guidelines that can be followed when introducing Service-oriented architecture through the use of Web services. This guideline… (more)

Adeyinka, Oluwaseyi

2008-01-01T23:59:59.000Z

482

E-Print Network 3.0 - acuc policies guidelines Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

a functioning animal care and use committee? (See ARAC Guidelines for ACUC Membership... Regulations? (See ARAC Guidelines for ACUC Membership and ... Source: Baker, Chris I. -...

483

E-Print Network 3.0 - association iuga guidelines Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

associated costs of different care options, effectiveness of the guideline in influencing health care... uses a guideline adaptation process established by the Registered Nurses...

484

Conceptual Safety Design RM | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Safety Design RM Conceptual Safety Design RM The Conceptual Safety Design (CSD) Review Module (RM) is a tool that assists DOE federal project review teams in evaluating the...

485

Manual for implementing residual radioactive material guidelines using RESRAD, Version 5.0  

SciTech Connect (OSTI)

This manual presents information for implementing US Department of Energy (DOE) guidelines for residual radioactive material. It describes the analysis and models used to derive site-specific guidelines for allowable residual concentrations of radionuclides in soil and the design and use of the RESRAD computer code for calculating doses, risks, and guideline values. It also describes procedures for implementing DOE policy for reducing residual radioactivity to levels that are as low as reasonably achievable. Two new pathways, radon inhalation and soil ingestion, have been added to RESRAD. Twenty-seven new radionuclides have also been added, and the cutoff half-life for associated radionuclides has been reduced to six months. Other major improvements to the RESRAD code include the ability to run sensitivity analyses, the addition of graphical output, user-specified dose factors, updated databases, an improved groundwater transport model, optional input of a groundwater concentration and a solubility constant, special models for tritium and carbon-14, calculation of cancer incidence risk, and the use of a mouse with menus.

Yu, C.; Zielen, A.J.; Cheng, J.J. [and others

1993-09-01T23:59:59.000Z

486

Adjudicative Guidelines for Determining Eligibility for Access to Classified Information  

Broader source: Energy.gov (indexed) [DOE]

Adjudicative Guidelines for Determining Eligibility for Adjudicative Guidelines for Determining Eligibility for Access to Classified Information 1. Introduction. The following adjudicative guidelines are established for all U.S. government civilian and military personnel, consultants, contractors, employees of contractors, licensees, certificate holders or grantees and their employees and other individuals who require access to classified information. They apply to persons being considered for initial or continued eligibility for access to classified information, to include sensitive compartmented information and special access programs, and are to be used by government departments and agencies in all final clearance determinations. Government departments and agencies may also choose to apply these

487

Guidelines, identity and competing needs: The effect of signage design guidelines on uniformity and variety in urban retail business districts.  

E-Print Network [OSTI]

??This study examines the competing needs of business owners and urban districts in communicating their respective graphic identities to potential customers through retail signage, and… (more)

Kim, Nanhee

2009-01-01T23:59:59.000Z

488

Recommendations for Guidelines for Environment-Specific Magnetic-Field Measurements, Rapid Program Engineering Project #2  

SciTech Connect (OSTI)

The purpose of this project was to document widely applicable methods for characterizing the magnetic fields in a given environment, recognizing the many sources co-existing within that space. The guidelines are designed to allow the reader to follow an efficient process to (1) plan the goals and requirements of a magnetic-field study, (2) develop a study structure and protocol, and (3) document and carry out the plan. These guidelines take the reader first through the process of developing a basic study strategy, then through planning and performing the data collection. Last, the critical factors of data management, analysis reporting, and quality assurance are discussed. The guidelines are structured to allow the researcher to develop a protocol that responds to specific site and project needs. The Research and Public Information Dissemination Program (RAPID) is based on exposure to magnetic fields and the potential health effects. Therefore, the most important focus for these magnetic-field measurement guidelines is relevance to exposure. The assumed objective of an environment-specific measurement is to characterize the environment (given a set of occupants and magnetic-field sources) so that information about the exposure of the occupants may be inferred. Ideally, the researcher seeks to obtain complete or "perfect" information about these magnetic fields, so that personal exposure might also be modeled perfectly. However, complete data collection is not feasible. In fact, it has been made more difficult as the research field has moved to expand the list of field parameters measured, increasing the cost and complexity of performing a measurement and analyzing the data. The guidelines address this issue by guiding the user to design a measurement protocol that will gather the most exposure-relevant information based on the locations of people in relation to the sources. We suggest that the "microenvironment" become the base unit of area in a study, with boundaries defined by the occupant's activity patterns and the field variation from the sources affecting the area. Such a stratification allows the researcher to determine which microenvironment are of most interest, and to methodically focus the areas, in order to gather the most relevant set of data.

Electric Research and Management, Inc.; IIT Research Institute; Magnetic Measurements; Survey Research Center, University of California; T. Dan Bracken, Inc.

1997-03-11T23:59:59.000Z

489

Summary Protocol: Identification, Characterization, Designation, Remedial  

Broader source: Energy.gov (indexed) [DOE]

Summary Protocol: Identification, Characterization, Designation, Summary Protocol: Identification, Characterization, Designation, Remedial Action, Certification Summary Protocol: Identification, Characterization, Designation, Remedial Action, Certification Summary Protocol: Identification, Characterization, Designation, Remedial Action, Certification (January 1986) Summary Protocol: Identification, Characterization, Designation, Remedial Action, Certification (January 1986) More Documents & Publications Supplement No. 1 to the FUSRAP Summary Protocol - Designation/Elimination Protocol Pre-MARSSIM Surveys in a MARSSIM World: Demonstrating How Pre-MARSSIM Radiological Data Demonstrate Protectiveness at Formerly Utilized Sites Remedial Action Program Sites U.S. Department of Energy Guidelines for Residual Radioactive Material at

490

Data acquisition user's guide-1 for fuel/engine evaluation system applied to an experimental air stirling engine. Technical note  

SciTech Connect (OSTI)

This technical note describes the Data Acquisition (DA) System used in the evaluation of Experimental Air Stirling Engine No. 1 which had previously been designed and built as a part of the Advanced Engines studies for the Fuels/Powerplants Technical Subprogram 25B. The DA system and capability is presented. Brief programming guidelines for controlling various peripheral electronic equipment through a mini-computer are given. The program software used in testing the Stirling engine is described. Finally, some limitations of the DA system are listed.

Bingham, I.R.; Webster, G.D.

1981-07-01T23:59:59.000Z

491

Requirements and guidelines for NSLS experimental beam line vacuum systems: Revision A  

SciTech Connect (OSTI)

Requirements are provided for NSLS beam line front ends and vacuum interlocks. Guidelines are provided for UHV beam line vacuum systems, including materials, vacuum hardware (pumps, valves, and flanges), acoustic delay lines and beam line fast valves, instrumentation, fabrication and testing, and the NSLS cleaning facility. Also discussed are the design review for experimenters' equipment that would be connected to the NSLS and acceptance tests for any beam line to be connected with the ring vacuum. Also appended are a description of the acoustic delay line as well as the NSLS vacuum standards and NSLS procedures. (LEW)

Foerster, C.; Halama, H.; Thomlinson, W.

1986-10-01T23:59:59.000Z

492

REVIEW Of COMPUTERIZED PROCEDURE GUIDELINES FOR NUCLEAR POWER PLANT CONTROL ROOMS  

SciTech Connect (OSTI)

Computerized procedures (CPs) are recognized as an emerging alternative to paper-based procedures for supporting control room operators in nuclear power plants undergoing life extension and in the concept of operations for advanced reactor designs. CPs potentially reduce operator workload, yield increases in efficiency, and provide for greater resilience. Yet, CPs may also adversely impact human and plant performance if not designed and implemented properly. Therefore, it is important to ensure that existing guidance is sufficient to provide for proper implementation and monitoring of CPs. In this paper, human performance issues were identified based on a review of the behavioral science literature, research on computerized procedures in nuclear and other industries, and a review of industry experience with CPs. The review of human performance issues led to the identification of a number of technical gaps in available guidance sources. To address some of the gaps, we developed 13 supplemental guidelines to support design and safety. This paper presents these guidelines and the case for further research.

David I Gertman; Katya Le Blanc; Ronald L Boring

2011-09-01T23:59:59.000Z

493

Guidelines for Estimating Unmetered Landscaping Water Use  

SciTech Connect (OSTI)

The document lays-out step by step instructions to estimate landscaping water using two alternative approaches: evapotranspiration method and irrigation audit method. The evapotranspiration method option calculates the amount of water needed to maintain a healthy turf or landscaped area for a given location based on the amount of water transpired and evaporated from the plants. The evapotranspiration method offers a relatively easy “one-stop-shop” for Federal agencies to develop an initial estimate of annual landscape water use. The document presents annual irrigation factors for 36 cities across the U.S. that represents the gallons of irrigation required per square foot for distinct landscape types. By following the steps outlined in the document, the reader can choose a location that is a close match their location and landscape type to provide a rough estimate of annual irrigation needs without the need to research specific data on their site. The second option presented in the document is the irrigation audit method, which is the physical measurement of water applied to landscaped areas through irrigation equipment. Steps to perform an irrigation audit are outlined in the document, which follow the Recommended Audit Guidelines produced by the Irrigation Association.[5] An irrigation audit requires some knowledge on the specific procedures to accurately estimate how much water is being consumed by the irrigation equipment.

McMordie Stoughton, Kate

2010-07-28T23:59:59.000Z

494

National Mitigation Planning in Agriculture: Review and Guidelines | Open  

Open Energy Info (EERE)

Agriculture: Review and Guidelines Agriculture: Review and Guidelines Jump to: navigation, search Name National Mitigation Planning in Agriculture: Review and Guidelines Agency/Company /Organization CGIAR's Climate Change, Agriculture and Food Security (CCAFS), Food and Agriculture Organization of the United Nations, UNIQUE Agroforestry Sector Land Focus Area Agriculture Topics Background analysis, Co-benefits assessment, - Environmental and Biodiversity, - Macroeconomic, Low emission development planning, -NAMA, -Roadmap, Pathways analysis, Policies/deployment programs Program Start 2012 Program End 2013 References CGIAR - CCAFS[1] This article is a stub. You can help OpenEI by expanding it. References ↑ "CGIAR - CCAFS" Retrieved from "http://en.openei.org/w/index.php?title=National_Mitigation_Planning_in_Agriculture:_Review_and_Guidelines&oldid=581360"

495

Adjudicative Guidelines for Determining Eligibility for Access to  

Broader source: Energy.gov (indexed) [DOE]

Adjudicative Guidelines for Determining Eligibility for Access to Adjudicative Guidelines for Determining Eligibility for Access to Classified Information Adjudicative Guidelines for Determining Eligibility for Access to Classified Information Introduction. The following adjudicative guidelines are established for all U.S. government civilian and military personnel, consultants, contractors, employees of contractors, licensees, certificate holders or grantees and their employees and other individuals who require access to classified information. They apply to persons being considered for initial or continued eligibility for access to classified information, to include sensitive compartmented information and special access programs, and are to be used by government departments and agencies in all final clearance determinations. Government departments and agencies may also choose to

496

Guidelines | U.S. DOE Office of Science (SC)  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Guidelines Guidelines High Energy Physics (HEP) HEP Home About Research Facilities Science Highlights Benefits of HEP Funding Opportunities Closed Funding Opportunity Announcements (FOAs) Closed Lab Announcements Award Search Peer Merit / Review Policies Early Career Research Opportunities in High Energy Physics Graduate Fellows in High Energy Theory Guidelines Comparative Review Annual Solicitation Progress Reports and Final Report Conferences Advisory Committees News & Resources Contact Information High Energy Physics U.S. Department of Energy SC-25/Germantown Building 1000 Independence Ave., SW Washington, DC 20585 P: (301) 903-3624 F: (301) 903-2597 E: sc.hep@science.doe.gov More Information » Funding Opportunities Guidelines Print Text Size: A A A RSS Feeds FeedbackShare Page

497

Biomass Guidelines (Prince Edward Island, Canada) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

You are here You are here Home » Biomass Guidelines (Prince Edward Island, Canada) Biomass Guidelines (Prince Edward Island, Canada) < Back Eligibility Agricultural Construction Developer Industrial Investor-Owned Utility Municipal/Public Utility Utility Program Info State Prince Edward Island Program Type Environmental Regulations PEI Biomass Guidelines identify two major pathways that biomass projects may follow: No Public Investment, and Public Investment. Projects with Public Investment include any project that has: * Grants or loans for start-up, capital, or operating costs; * Silvicultural or other land management incentives provided through Departmental programs (e.g. Forest Enhancement Program, ALUS); or * Green credits or certification from Government. Guidelines for No Public Investment projects must only comply with existing

498

ASC Logo Use Guidelines | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Logo Use Guidelines | National Nuclear Security Administration Logo Use Guidelines | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog ASC Logo Use Guidelines Home > About Us > Our Programs > Defense Programs > Future Science & Technology Programs > Office of Advanced Simulation and Computing and Institutional R&D Programs > ASC Publications > ASC Logo Use Guidelines

499

OPC Security Whitepaper #3Hardening Guidelines for OPC Hosts | Department  

Broader source: Energy.gov (indexed) [DOE]

OPC Security Whitepaper #3Hardening Guidelines for OPC Hosts OPC Security Whitepaper #3Hardening Guidelines for OPC Hosts OPC Security Whitepaper #3Hardening Guidelines for OPC Hosts In recent years, Supervisory Control and Data Acquisition (SCADA), process control and industrial manufacturing systems have increasingly relied on commercial Information Technologies (IT) such as Ethernet(tm), Transmission Control Protocol/Internet Protocol (TCP/IP) and Windows® for both critical and non-critical communications. This has made the interfacing of industrial control equipment much easier, but has resulted in significantly less isolation from the outside world, resulting in the increased risk of cyber-based attacks impacting industrial production and human safety. OPC Security Whitepaper #3 Hardening Guidelines for OPC Hosts

500

Guidelines for Solar and Wind Local Ordinances (Virginia) | Department of  

Broader source: Energy.gov (indexed) [DOE]

Guidelines for Solar and Wind Local Ordinances (Virginia) Guidelines for Solar and Wind Local Ordinances (Virginia) Guidelines for Solar and Wind Local Ordinances (Virginia) < Back Eligibility Agricultural Commercial Fed. Government General Public/Consumer Industrial Installer/Contractor Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal Utility Nonprofit Residential Rural Electric Cooperative Schools State Government Tribal Government Utility Savings Category Solar Buying & Making Electricity Wind Program Info State Virginia Program Type Solar/Wind Permitting Standards In March 2011, the Virginia legislature enacted broad guidelines for local ordinances for solar and wind. The law states that any local ordinance related to the siting of solar or wind energy facilities must: