Powered by Deep Web Technologies
Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

COLD STORAGE DESIGN REFRIGERATION EQUIPMENT  

E-Print Network (OSTI)

COLD STORAGE DESIGN AND REFRIGERATION EQUIPMENT REFRIGERATION OF FISH - PART 1 \\ "..\\- ,,, T I Fishery Leaflet 427 Washington 25, D. C. June 1956 REFRIGERATION OF FISH - PART em; COlD STORAGE DESIGN · · · · · 18 Specific design features 0 0 · · · · · · · · · · · · · · 19 Refrigerated surfaces 0 · · 0 0 0 · 0

2

COMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATION SYSTEMS  

E-Print Network (OSTI)

be used to design and optimize refrigeration cycles as wellCOMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATIONTrial Design Fixed state parameters (bar) Refrigeration

green, M.A.

2011-01-01T23:59:59.000Z

3

Design of Industrial Process Refrigeration Systems  

E-Print Network (OSTI)

When considering electric driven refrigeration compressors, proper integration with the process may result in reduced power consumption. However, the total utility situation must be considered when evaluating the compressor driver. Conversion from steam drivers to electric drivers may be more economical when considering proper process integration. These questions and various scenarios must be addressed in light of the total process requirements and constraints. During the last few years, Union Carbide has successfully applied ADVENT technology to several complex processes that utilize refrigeration systems. In most cases the design of a complex refrigeration system in isolation (i.e., without considering process integration) generally results in non-optimum refrigeration levels and excessive refrigeration consumption. By applying ADVENT Process Integration Technologv to these non-optimal designs, retrofit projects have emerged that clearly identify how to optimize the existing design with good project economics. This paper presents the results of an ADVENT Process Integration Study for the Electric Power Research Institute (EPRI) of Palo Alto, California. The study objective was to demonstrate process synthesis techniques for retrofit design in two industrial refrigeration intensive processes: an olefins process and a beer brewery process. Study results for each retrofit design are explained along with generalized guidelines for application to other processes. An industry scoping portion of the study is discussed in terms of identifying refrigeration intensive processes. Specific and general conclusions are presented to help facilitate proper industrial refrigeration system design throughout the industry.

Witherell, W. D.

1987-09-01T23:59:59.000Z

4

New waste-heat refrigeration unit cuts flaring, reduces pollution  

Science Conference Proceedings (OSTI)

Planetec Utility Services Co. Inc. and Energy Concepts Co. (ECC), with the help of the US Department of Energy (DOE), developed and commissioned a unique waste-heat powered LPG recovery plant in August 1997 at the 30,000 b/d Denver refinery, operated by Ultramar Diamond Shamrock (UDS). This new environmentally friendly technology reduces flare emissions and the loss of salable liquid-petroleum products to the fuel-gas system. The waste heat ammonia absorption refrigeration plant (Whaarp) is the first technology of its kind to use low-temperature waste heat (295 F) to achieve sub-zero refrigeration temperatures ({minus}40 F) with the capability of dual temperature loads in a refinery setting. The ammonia absorption refrigeration is applied to the refinery`s fuel-gas makeup streams to condense over 180 b/d of salable liquid hydrocarbon products. The recovered liquid, about 64,000 bbl/year of LPG and gasoline, increases annual refinery profits by nearly $1 million, while substantially reducing air pollution emissions from the refinery`s flare.

Brant, B.; Brueske, S. [Planetec Utility Services Co., Inc., Evergreen, CO (United States); Erickson, D.; Papar, R. [Energy Concepts Co., Annapolis, MD (United States)

1998-05-18T23:59:59.000Z

5

Optimal Design Refrigeration System for a Mucilage Glue Fiber Factory  

E-Print Network (OSTI)

In a mucilage glue fiber factory, the design of the refrigeration system takes into account the characteristics of mucilage glue fiber production and fully uses the refrigeration compressor heat to economize energy and reduce the production cost. In this paper, the author introduces different points of this kind of design with conventional design. For efficient use of the compressed heat of the refrigeration system, the designer should calculate the number of condensers according to the changes that the refrigeration system undergoes after using the soft water as cooling water. To economize the investment, the designer should use the refrigeration workshop and the soft water workshop and obtain optimum processing to shorten the duct. Through an economizing energy analysis, the paper demonstrates that an optimum design for a refrigeration system for a mucilage glue factory has a significant energy saving potential.

Tan, C.; Liu, J.; Tang, F.; Liu, Y.

2006-01-01T23:59:59.000Z

6

Designing Environmentally Safe Refrigerants Using Mathematical Programming  

E-Print Network (OSTI)

Computer aided molecular design is a strategy in which a set of structural groups are systematically combined to form molecules with desired properties. In this paper, a mathematical programming based approach to computer aided molecular design is presented. Using a set of structural groups, the problem is formulated as a mixed integer nonlinear program in which discrete variables represent the number of each type of structural groups present in the candidate compound. The augmentedpenalty /outer-approximation algorithm is used to solve the MINLP to obtain compound(s) with an optimum value of an appropriate performance index such that molecular structural constraints, physical property constraints and process design limitations are met. With the current renewed interest in the environment, the suggested approach is applied to refrigerant design with an environmental constraint. The results indicate the viability of this approach. INTRODUCTION The chemical industry is constantly explo...

Amit P. Duvedi; Luke E. K. Achenie; Copyright Amit Duvedi; Luke Achenie

1996-01-01T23:59:59.000Z

7

Reducing the Carbon Footprint of Commercial Refrigeration Systems Using Life Cycle Climate Performance Analysis: From System Design to Refrigerant Options  

SciTech Connect

In this paper, Life Cycle Climate Performance (LCCP) analysis is used to estimate lifetime direct and indirect carbon dioxide equivalent gas emissions of various refrigerant options and commercial refrigeration system designs, including the multiplex DX system with various hydrofluorocarbon (HFC) refrigerants, the HFC/R744 cascade system incorporating a medium-temperature R744 secondary loop, and the transcritical R744 booster system. The results of the LCCP analysis are presented, including the direct and indirect carbon dioxide equivalent emissions for each refrigeration system and refrigerant option. Based on the results of the LCCP analysis, recommendations are given for the selection of low GWP replacement refrigerants for use in existing commercial refrigeration systems, as well as for the selection of commercial refrigeration system designs with low carbon dioxide equivalent emissions, suitable for new installations.

Fricke, Brian A [ORNL; Abdelaziz, Omar [ORNL; Vineyard, Edward Allan [ORNL

2013-01-01T23:59:59.000Z

8

Evolution of the Standard Helium Liquefier and Refrigerator Range designed by Air Liquide DTA, France  

E-Print Network (OSTI)

Evolution of the Standard Helium Liquefier and Refrigerator Range designed by Air Liquide DTA, France

Crispel, S; Caillaud, A; Delcayre, F; Grabie, V

2008-01-01T23:59:59.000Z

9

Designing Augmented Refrigerator Magnets Rachel Eardley, Laurel Swan  

E-Print Network (OSTI)

Designing Augmented Refrigerator Magnets Rachel Eardley, Laurel Swan , Abi Sellen Alex S. Taylor In this poster we present the conceptual designs for several augmented fridge magnets, each illustrative of a larger number of concepts being explored and implemented. The designs have been informed through ongoing

Hunt, Galen

10

Development of Low Global Warming Potential Refrigerant Solutions for Commercial Refrigeration Systems using a Life Cycle Climate Performance Design Tool  

SciTech Connect

Commercial refrigeration systems are known to be prone to high leak rates and to consume large amounts of electricity. As such, direct emissions related to refrigerant leakage and indirect emissions resulting from primary energy consumption contribute greatly to their Life Cycle Climate Performance (LCCP). In this paper, an LCCP design tool is used to evaluate the performance of a typical commercial refrigeration system with alternative refrigerants and minor system modifications to provide lower Global Warming Potential (GWP) refrigerant solutions with improved LCCP compared to baseline systems. The LCCP design tool accounts for system performance, ambient temperature, and system load; system performance is evaluated using a validated vapor compression system simulation tool while ambient temperature and system load are devised from a widely used building energy modeling tool (EnergyPlus). The LCCP design tool also accounts for the change in hourly electricity emission rate to yield an accurate prediction of indirect emissions. The analysis shows that conventional commercial refrigeration system life cycle emissions are largely due to direct emissions associated with refrigerant leaks and that system efficiency plays a smaller role in the LCCP. However, as a transition occurs to low GWP refrigerants, the indirect emissions become more relevant. Low GWP refrigerants may not be suitable for drop-in replacements in conventional commercial refrigeration systems; however some mixtures may be introduced as transitional drop-in replacements. These transitional refrigerants have a significantly lower GWP than baseline refrigerants and as such, improved LCCP. The paper concludes with a brief discussion on the tradeoffs between refrigerant GWP, efficiency and capacity.

Abdelaziz, Omar [ORNL; Fricke, Brian A [ORNL; Vineyard, Edward Allan [ORNL

2012-01-01T23:59:59.000Z

11

COMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATION SYSTEMS  

E-Print Network (OSTI)

One Stage Compressor Heat Exchanger Refrigeration Load XBLOne Stage Compressor Heat Exchanger Refrigeration Load XBLcondensers, surface heat exchangers, surface condensers,

green, M.A.

2011-01-01T23:59:59.000Z

12

Prototype arc saw design and cutting trials  

SciTech Connect

A program was initiated to develop the arc saw as a tool capable of removing the end fittings from spent nuclear fuel bundles. A special arc saw for this purpose was designed, installed at the Pacific Northwest Laboratory and satisfactorily operated to remove end fittings from simulated, nonradioactive fuel bundles. The design of the arc saw included consideration of the cutting environment, power supply size, control equipment, and work piece size. Several simulated fuel bundles were cut to demonstrate that the arc saw met design specifications. Although the arc saw development program was curtailed before significant performance data could be collected, tests indicate that the arc saw is a good means of cropping spent fuel bundles and is well suited to remote operation and maintenance.

Allison, G.S.

1980-09-01T23:59:59.000Z

13

Chapter 6: Refrigeration Process Control: A Formal Design Approach 111 66.. RREEFFRRIIGGEERRAATTIIOONN PPRROOCCEESSSS  

E-Print Network (OSTI)

Chapter 6: Refrigeration Process Control: A Formal Design Approach 111 66 are summarised in Table 6.1 below. #12;Chapter 6: Refrigeration Process Control: A Formal Design Approach 112 on #12;Chapter 6: Refrigeration Process Control: A Formal Design Approach 113 the steady state gain

Skogestad, Sigurd

14

Chapter 5: Refrigeration Process Control: A Pragmatic Design Approach 75 55.. RREEFFRRIIGGEERRAATTIIOONN PPRROOCCEESSSS  

E-Print Network (OSTI)

Chapter 5: Refrigeration Process Control: A Pragmatic Design Approach 75 55. #12;Chapter 5: Refrigeration Process Control: A Pragmatic Design Approach 76 This leaves up to three from a different perspective #12;Chapter 5: Refrigeration Process Control: A Pragmatic Design Approach

Skogestad, Sigurd

15

Design and Analysis of a Nested Halbach Permanent Magnet Magnetic Refrigerator  

E-Print Network (OSTI)

Design and Analysis of a Nested Halbach Permanent Magnet Magnetic Refrigerator by Armando Tura BEng Committee Design and Analysis of a Nested Halbach Permanent Magnet Magnetic Refrigerator by Armando Tura with the potential to create efficient and compact refrigeration devices is an active magnetic regenerative

Victoria, University of

16

Bubble Pump Design for Single Pressure Absorption Refrigeration Cycles  

E-Print Network (OSTI)

A model has been developed for the design and optimization of a small bubble pump to be used in a single pressure absorption refrigeration cycle to lift the working fluid mixture against gravity and overcome flow friction. This analytical model is developed from two-phase flow fundamentals and incorporates the design parameters of the bubble pump. Parametric studies are carried out and a design optimization for maximum efficiency is performed for various operating conditions. Optimum efficiency is defined as the liquid pumped per unit of bubble pump heat input. The results show the optimum bubble pump tube diameter over a range of operating conditions.

Sam V. Shelton; Susan White Stewart

2002-01-01T23:59:59.000Z

17

System design and simulation of constant temperature box using semiconductor refrigeration device  

Science Conference Proceedings (OSTI)

This paper presents the variation law of temperature in three-dimensional space, which is cooled by the refrigeration provided by the cold side of a semiconductor. The mathematical model of the temperature field of the semiconductor refrigeration ... Keywords: constant temperature box, forced convection, mathematical modelling, numerical simulation, semiconductor refrigeration, system design

Hui Zhang; Kuang-Chao Fan; Jun Wang

2010-03-01T23:59:59.000Z

18

Investigation of a Hybrid Cutting Tool Design for Shearing ...  

Science Conference Proceedings (OSTI)

Presentation Title, Investigation of a Hybrid Cutting Tool Design for Shearing Operations of ... Challenges in Applying Diamond Coatings to Carbide Twist Drills.

19

Sustainable design of hydrocarbon refrigerants applied to the hermetic compressor.  

E-Print Network (OSTI)

??International environmental concern led to the control and phase out of traditional chlorofluorocarbon refrigerants (CFCs) under the terms of the Montreal protocol. CFCs used in (more)

Garland, Nigel P.

2004-01-01T23:59:59.000Z

20

PROCESS DESIGN AND CONTROL Steady-State Operational Degrees of Freedom with Application to Refrigeration  

E-Print Network (OSTI)

PROCESS DESIGN AND CONTROL Steady-State Operational Degrees of Freedom with Application to Refrigeration Cycles Jørgen Bauck Jensen and Sigurd Skogestad* Department of Chemical Engineering, Norwegian Uni of the circulating refrigerant are also discussed. Two liquified natural gas (LNG) processes of current interest

Skogestad, Sigurd

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Design and installation considerations for refrigerant charged thermosyphoning solar DHW systems  

SciTech Connect

The recent introduction of refrigerants into the realm of passive solar technologies has provided some advantages in performance over the typical liquid solar domestic hot water system. These advantages can be offset by the lack of familiarity by designers or installers with the operation, layout or components of a phase-change thermosyphon water heater. The considerations which were evaluated in the design and installation of a passive solar domestic hot water system in Golden, Colorado, are described. A discussion of collector selection, storage and heat exchanger design, refrigerant type selection, system integration design, and refrigeration requirements is presented.

DeAngelis, M.; Nordham, D.

1980-01-01T23:59:59.000Z

22

Conceptual design of an advanced absorption cycle: the double-effect regenerative absorption refrigeration cycle  

DOE Green Energy (OSTI)

An advanced absorption refrigeration cycle was proposed as a heat-activated refrigeration system. Referred to as the double-effect regenerative absorption cycle of cycle 2R, it improves the performance of the conventional single-effect absorption cycle at high heat source temperatures. The performance of cycle 2R continually improves as input temperatures rise, in contrast to the conventional double-effect absorption cycle that has a sharp cut-off temperature below which it ceases to operate. Cycle 2R operates with two subcycles, the first-effect and the second-effect subcycles.

Dao, K.

1978-09-01T23:59:59.000Z

23

Applying Ecological Interface Design to Experimental Apparatus Used to Monitor a Refrigeration Plant.  

E-Print Network (OSTI)

A small refrigeration plant, for teaching refrigeration theory, used a control console built to traditional design guidelines: one output in the display for each sensor in the plant. This style of console is notorious for inducing high cognitive loads on operators and for displaying redundant data. Often the high cognitive load is the result of inconsistency between the intent for displaying the data and the format of the displayed data. An interface, based on Ecological Interface Design Theory (EID) was designed and implemented. The completed interface provided the operator with information commensurate with the operator's mental model derived from the system image. During testing of the new interface the expert operator's mental model of the refrigeration system was modified due to improved observation of the refrigeration plant's operational parameters. The application achieved the desired result and reduced the operator's workload by removing a cognitive task - determining system s...

Pat Lehane; Mark Toleman; John Benecke

2000-01-01T23:59:59.000Z

24

On the Use of a Mixed Integer Nonlinear Programming Model for Refrigerant Design  

E-Print Network (OSTI)

In this paper, a novel mixed integer nonlinear programming model for single component refrigerant design is presented. At the heart of the approach is a new formulation for structural feasibility that allows multiple bonds, connectivity and isomers. The strategy defines a set of structural groups (consisting of atoms), subsets of which are combined to form refrigerant molecules. Molecules formed this way must obey structural and stability constraints. The design objective is to build a refrigerant molecule that has desired physical properties and performance characteristics. These attributes are formulated as mathematical programming constraints and performance objectives which involve both continuous and integer variables. With the current renewed interest in the environment, the suggested approach is applied to refrigerant design with an environmental constraint. The results indicate the viability and the flexibility of the approach. 1 Introduction The search for new compounds wit...

In International; Nachiket Churi; Luke E. K. Achenie; Copyright Luke; E. K. Achenie

1997-01-01T23:59:59.000Z

25

The effect of new priorities and new materials on residential refrigerator design  

Science Conference Proceedings (OSTI)

Increasing energy-efficiency requirements, combined with environmental considerations, have resulted in designs for domestic refrigerators that incorporate new thermal insulating materials. The first series of tests of these materials have been sufficiently promising that incorporation of vacuum insulations if likely within the next several years. Initial designs will probably use a combination of vacuum insulations and foam; in future designs, major parts consolidation will be possible using structural and other characteristics of the new panel assemblies. Given optimization of the refrigerator thermal envelope according to life-cycle costs, energy use by refrigerators could be greatly reduced; refrigerators could lose their significance as a major component in residential energy-use. Possible forms in which these new materials will be used are discussed, including alternatives for composite assembly and requirements for reliability and durability.

Benson, D.K.; Potter, T.F.

1992-08-01T23:59:59.000Z

26

COMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATION SYSTEMS  

E-Print Network (OSTI)

and the assumed electrical energy cost is $0.04 per kWh.cost (the cost is given in US$ per kWh at 80.4°K) andThe cost of nitrogen refrigeration given in $ per kWh at

green, M.A.

2011-01-01T23:59:59.000Z

27

The Energy-Saving Design Practices for Direct Cooling Refrigerator  

Science Conference Proceedings (OSTI)

The area of evaporator on cold storage chamber was added under a constant total evaporator area. Composite and stereoscopic structure with laminated exchanger flake was used on evaporator of freezing chamber. Wing - flakes were fixed outside the refrigerant ... Keywords: refrigerantion, energy-saving, condensor, evaporator

Cai Yingling; Zhang Hua; Chen Shuai; Li Gang; Xia Peng

2009-10-01T23:59:59.000Z

28

NREL's Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants (Fact Sheet)  

SciTech Connect

This fact sheet describes how the DEVAP air conditioner was invented, explains how the technology works, and why it won an R&D 100 Award. Desiccant-enhanced evaporative (DEVAP) air-conditioning will provide superior comfort for commercial buildings in any climate at a small fraction of the electricity costs of conventional air-conditioning equipment, releasing far less carbon dioxide and cutting costly peak electrical demand by an estimated 80%. Air conditioning currently consumes about 15% of the electricity generated in the United States and is a major contributor to peak electrical demand on hot summer days, which can lead to escalating power costs, brownouts, and rolling blackouts. DEVAP employs an innovative combination of air-cooling technologies to reduce energy use by up to 81%. DEVAP also shifts most of the energy needs to thermal energy sources, reducing annual electricity use by up to 90%. In doing so, DEVAP is estimated to cut peak electrical demand by nearly 80% in all climates. Widespread use of this cooling cycle would dramatically cut peak electrical loads throughout the country, saving billions of dollars in investments and operating costs for our nation's electrical utilities. Water is already used as a refrigerant in evaporative coolers, a common and widely used energy-saving technology for arid regions. The technology cools incoming hot, dry air by evaporating water into it. The energy absorbed by the water as it evaporates, known as the latent heat of vaporization, cools the air while humidifying it. However, evaporative coolers only function when the air is dry, and they deliver humid air that can lower the comfort level for building occupants. And even many dry climates like Phoenix, Arizona, have a humid season when evaporative cooling won't work well. DEVAP extends the applicability of evaporative cooling by first using a liquid desiccant-a water-absorbing material-to dry the air. The dry air is then passed to an indirect evaporative cooling stage, in which the incoming air is in thermal contact with a moistened surface that evaporates the water into a separate air stream. As the evaporation cools the moistened surface, it draws heat from the incoming air without adding humidity to it. A number of cooling cycles have been developed that employ indirect evaporative cooling, but DEVAP achieves a superior efficiency relative to its technological siblings.

Not Available

2012-07-01T23:59:59.000Z

29

Design and development of a wheelchair-accessible, residential refrigeration device: A Case Study of a Technical Assistance Project administered through the  

E-Print Network (OSTI)

Design and development of a wheelchair-accessible, residential refrigeration device: A Case Study Refrigeration unit with transparent doors US Patent. D517572 - Filed Dec 6, 2004 United States Design Patent perishable items from a conventional refrigerator, Dr. John Imre, Chippewa Falls, WI, produced a design and

Wu, Mingshen

30

OPTIMAL DESIGN AND OPERATION OF HELIUM REFRIGERATION SYSTEMS USING THE GANNI CYCLE  

SciTech Connect

The constant pressure ratio process, as implemented in the floating pressure - Ganni cycle, is a new variation to prior cryogenic refrigeration and liquefaction cycle designs that allows for optimal operation and design of helium refrigeration systems. This cycle is based upon the traditional equipment used for helium refrigeration system designs, i.e., constant volume displacement compression and critical flow expansion devices. It takes advantage of the fact that for a given load, the expander sets the compressor discharge pressure and the compressor sets its own suction pressure. This cycle not only provides an essentially constant system Carnot efficiency over a wide load range, but invalidates the traditional philosophy that the (TS) design condition is the optimal operating condition for a given load using the as-built hardware. As such, the Floating Pressure- Ganni Cycle is a solution to reduce the energy consumption while increasing the reliability, flexibility and stability of these systems over a wide operating range and different operating modes and is applicable to most of the existing plants. This paper explains the basic theory behind this cycle operation and contrasts it to the traditional operational philosophies presently used.

Venkatarao Ganni, Peter Knudsen

2010-04-01T23:59:59.000Z

31

Fridge of the future: Designing a one-kilowatt-hour/day domestic refrigerator-freezer  

SciTech Connect

An industry/government Cooperative Research and Development Agreement (CRADA) was established to evaluate and test design concepts for a domestic refrigerator-freezer unit that represents approximately 60% of the US market. The goal of the CRADA was to demonstrate advanced technologies which reduce, by 50 percent, the 1993 NAECA standard energy consumption for a 20 ft{sup 3} (570 I) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translated to an energy consumption of 1.003 kWh/d. The general objective of the research was to facilitate the introduction of cost-efficient technologies by demonstrating design changes that can be effectively incorporated into new products. A 1996 model refrigerator-freezer was selected as the baseline unit for testing. Since the unit was required to meet the 1993 NAECA standards, the energy consumption was quite low (1.676 kWh/d), thus making further reductions in energy consumption very challenging. Among the energy saving features incorporated into the original design of the baseline unit were a low-wattage evaporator fan, increased insulation thicknesses, and liquid line flange heaters.

Vineyard, E.A.; Sand, J.R.

1998-03-01T23:59:59.000Z

32

Design and Analysis of a Nested Halbach Permanent Magnet Magnetic Refrigerator.  

E-Print Network (OSTI)

??A technology with the potential to create efficient and compact refrigeration devices is an active magnetic regenerative refrigerator (AMRR). AMRRs exploit the magnetocaloric effect displayed (more)

Tura, Armando

2013-01-01T23:59:59.000Z

33

Design of a single orifice pulse tube refrigerator through the development of a first-order model  

E-Print Network (OSTI)

A first order model for the behavior of a linear orifice pulse tube refrigerator (OPTR) was developed as a design tool for construction of actual OPTRs. The model predicts cooling power as well as the pressure/volume ...

Schor, Alisha R. (Alisha Robin)

2007-01-01T23:59:59.000Z

34

Design of a scanning gate microscope in a cryogen-free dilution refrigerator  

E-Print Network (OSTI)

We report on our design of a scanning gate microscope housed in a cryogen-free dilution refrigerator with a base temperature of 15 mK. The recent increase in efficiency of pulse tube cryocoolers has made cryogen-free systems popular in recent years. However, this new style of cryostat presents challenges for performing scanning probe measurements, mainly as a result of the vibrations introduced by the cryocooler. We demonstrate scanning with root-mean-square vibrations of 0.8 nm at 3 K and 2.1 nm at 15 mK in a 1 kHz bandwidth with our design.

Pelliccione, Matthew; Bartel, John; Keller, Andrew; Goldhaber-Gordon, David

2012-01-01T23:59:59.000Z

35

Evaluation of design options for improving the energy efficiency of an environmentally safe domestic refrigerator-freezer  

SciTech Connect

In order to reduce greenhouse emissions from power plants and respond to regulatory actions arising from the National Appliance Energy Conservation Act (NAECA), several design options were investigated for improving the energy efficiency of a conventionally designed, domestic refrigerator-freezer. The options, such as improved cabinet insulation and high-efficiency compressor and fans, were incorporated into a prototype refrigerator-freezer cabinet and refrigeration system to produce a unit that is superior from an environmental viewpoint due to its lower energy consumption and the use of refrigerant HFC-134a as a replacement for CFC-12. Baseline energy performance of the original 1993 production refrigerator-freezer, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. A detailed refrigerator system computer model was used to evaluate the energy savings for several design modifications that, collectively, could achieve a targeted energy consumption of 1.00 kWh/d for a 20 ft{sup 3} (570 l) top-mount, automatic-defrost, refrigerator-freezer. The energy consumption goal represents a 50% reduction in the 1993 NAECA standard for units of this size. Following the modeling simulation, laboratory prototypes were fabricated and tested to experimentally verify the analytical results and aid in improving the model in those areas where discrepancies occurred. While the 1.00 kWh/d goal was not achieved with the modifications, a substantial energy efficiency improvement of 22% (1.41 kWh/d) was demonstrated using near-term technologies. It is noted that each improvement exacts a penalty in terms of increased cost or system complexity/reliability. Further work on this project will analyze cost-effectiveness of the design changes and investigate alternative, more-elaborate, refrigeration system changes to further reduce energy consumption.

Vineyard, E.A.; Sand, J.R. [Oak Ridge National Lab., TN (United States); Bohman, R.H.

1995-03-01T23:59:59.000Z

36

NICE3: Industrial Refrigeration System  

SciTech Connect

Energy Concepts has developed an absorption-augmented system as a cost-effective means of achieving more cooling capacity with a substantial reduction in energy consumption and greenhouse gas emissions for industrial refrigeration. It cuts fuel consumption by 30% by combining an internal combustion engine with a mechanical compression refrigeration system and an absorption refrigeration system. The absorption system is powered by engine waste heat. Conventional industrial refrigeration uses mechanical vapor compression, powered by electric motors, which results in higher energy costs. By the year 2010, the new system could cut fuel consumption by 19 trillion Btu and greenhouse emissions by more than 1 million tons per year.

Simon, P.

1999-09-29T23:59:59.000Z

37

Solar refrigeration in rural West Bengal: Design of a product service system.  

E-Print Network (OSTI)

??Solarbear is a refrigerator that cools with the heat of the sun only. This technology, more formally known as solar powered adsorption cooling, has been (more)

Van Genuchten, R.P.

2011-01-01T23:59:59.000Z

38

Performance analysis of developed vegetable-based cutting fluids by D-optimal experimental design in turning process  

Science Conference Proceedings (OSTI)

The aim of this study is to determine the performances of developed vegetable-based cutting fluids VBCFs evaluated as a categorical factor with mineral and semi-synthetic cutting fluids CFs. D-optimal experimental design method in machining was used ... Keywords: D-optimal, EP additive, cutting force, surface roughness, turning, vegetable-based cutting fluids

Emel Kuram; M. Huseyin Cetin; Babur Ozcelik; Erhan Demirbas

2012-12-01T23:59:59.000Z

39

Advanced insulations for refrigerator/freezers: The potential for new shell designs incorporating polymer barrier construction  

Science Conference Proceedings (OSTI)

The impending phase-out of chlorofluorocarbons (CFCs) used to expand foam insulation, combined with requirements for increased energy efficiency, make the use of non-CFC-based high performance insulation technologies increasingly attractive. The majority of current efforts are directed at using advanced insulations in the form of thin, flat low-conductivity gas-filled or evacuated orthogonal panels, which we refer to as Advanced Insulation Panels (AIPs). AIPs can be used in composite with blown polymer foams to improve insulation performance in refrigerator/freezers (R/Fs) of conventional design and manufacture. This AIP/foam composite approach is appealing because it appears to be a feasible, near-term method for incorporating advanced insulations into R/Fs without substantial redesign or retooling. However, the requirements for adequate flow of foam during the foam-in-place operation impose limitations on the allowable thickness and coverage area of AIPs. This report examines design alternatives which may offer a greater increase in overall thermal resistance than is possible with the use of AIP/foam composites in current R/F design. These design alternatives generally involve a basic redesign of the R/F taking into account the unique requirements of advanced insulations and the importance of minimizing thermal bridging with high thermal resistance insulations. The focus here is on R/F doors because they are relatively simple and independent R/F components and are therefore good candidates for development of alterative designs. R/F doors have significant thermal bridging problems due to the steel outer shell construction. A three dimensional finite difference computer modeling exercise of a R/F door geometry was used to compare the overall levels of thermal resistance (R-value) for various design configurations.

Griffith, B.T.; Arasteh, D.

1992-11-01T23:59:59.000Z

40

On The Design Of Environmentally Benign Refrigerant Mixtures: A Mathematical Programming Approach  

E-Print Network (OSTI)

Chlorofluorocarbon (CFC) based refrigerants (such as CFC12) have found widespread uses in home refrigerators and automotive air conditioners primarily due to their nontoxic, nonflammable nature and their high overall thermodynamic efficiency. However, CFC and hydrofluorocarbon (HCFC) refrigerants with intermediate to high ozone depletion potentials (ODP's) will be banned during the next two decades. The outcome of replacing CFC's in the vapor recompression cycle and various other processes is vital to several industries. Feasible solutions appear to include mixtures of hydrofluorocarbons (HFC's) which have the potential for matching thermodynamic properties of current working fluids while meeting several criteria for ozone depletion potential, flammability, toxicity, materials compatibility and cost. In this paper, a proof of concept study is made to show that mathematical programming can effectively be used to identify a small set of alternative refrigerant mixtures which can then be...

Amit Duvedi; Luke E.K. Achenie; Copyright Luke Achenie

1997-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Physicist John Schmidt, designer of cutting-edge fusion facilities, dies at  

NLE Websites -- All DOE Office Websites (Extended Search)

Physicist John Schmidt, designer of cutting-edge fusion facilities, dies at Physicist John Schmidt, designer of cutting-edge fusion facilities, dies at 72 By John Greenwald February 15, 2013 Tweet Widget Facebook Like Google Plus One John Schmidt, 1940-2013 (Photo by Elle Starkman) John Schmidt, 1940-2013 Physicist John Schmidt, whose profound and wide-ranging contributions to the U.S. Department of Energy's Princeton Plasma Physics Laboratory (PPPL) made him a highly respected leader in the worldwide quest for fusion energy, died on February 13 following a brain hemorrhage. He was 72. Schmidt won wide acclaim for heading the design of cutting-edge facilities for magnetic fusion research during a 36-year career at PPPL, from which he retired in 2005. As interim director in 1996 he led the Laboratory's successful transition from large, fusion power-producing experiments such

42

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alterative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on various refrigerants. It addresses lubricants including alkylbenzene, polyalkylene glycol, polyolester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents. They are included to accelerate availability of the information and will be completed or replaced in future updates.

Calm, J.M.

1997-02-01T23:59:59.000Z

43

Opportunities for Energy Efficiency and Automated Demand Response in Industrial Refrigerated Warehouses in California  

E-Print Network (OSTI)

system. The refrigeration system design involves sizing ofDesign Essentials for Refrigerated Storage Facilities, American Society for Heating Refrigeration anddesign considerations are mostly related to wall and roof types, shell insulation, and the refrigeration

Lekov, Alex

2009-01-01T23:59:59.000Z

44

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

of the tower An (earlier) alternative is to use a spray pond to cool water; disadvantages are a large areaRefrigerationRefrigerationRefrigeration coursecourse # 424503.0# 424503.0 v.v. 20122012 7. Air conditioning, cooling towersg, g Ron Zevenhoven ??bo, is the hi htemperature at which condensation begins when air is cooled at constant pressurecooled

Zevenhoven, Ron

45

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

refrigeration processes (4 5) Vapor-compression refrigeration processes (4-5) Absorption refrigeration; Gas processing (O2, H2, CO2, LPG, LNG...) (3) Air conditioning, cooling towers, rg/pages/zon Air conditioning, cooling towers, food cooling and freezing (4) Heat pumps, heat pipes, special ww.sgisland.o p p

Zevenhoven, Ron

46

ARTI Refrigerant Database  

Science Conference Proceedings (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The complete documents are not included, though some may be added at a later date. The database identifies sources of specific information on R-32, R-123, R-124, R- 125, R-134a, R-141b, R142b, R-143a, R-152a, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses polyalkylene glycol (PAG), ester, and other lubricants. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits.

Calm, J.M.

1992-04-30T23:59:59.000Z

47

Refrigerator Efficiency in Ghana: Tailoring an appliance markettransformation program design for Africa  

SciTech Connect

A simple replication of developed country applianceefficiency labels and standards is unlikely to be feasible in Ghana andmany other countries in Africa. Yet by creatively modifying the developedcountry appliance efficiency market transformation model, it should bepossible to achieve dramatic energy use reductions. As was true indeveloped countries in the previous two decades, refrigeration efficiencyimprovements provide the greatest energy savings potential in theresidential electricity sector in Ghana. Although Ghana, like manyAfrican countries may impose standards on imports since Ghana does nothave manufacturing facilities for appliances in country. This approachmay hurt some consumers who patronize a very diverse market of usedappliances imported from Europe. We discuss how meeting the challenges ofthe Ghanaian market will require modification of the usual energyefficiency labeling and standards paradigm. But once a refrigeratormarket transformation is accomplished in Ghana, we estimate an averageenergy savings potential of 550 kWh/refrigerator/year, and a monetarysavings of more than $35/refrigerator/year. We discuss how this modifiedrefrigerator efficiency market transformation may occur in the Ghanaiancontext. If successful, this market transformation is likely to be anexample for many other African countries.

Ben Hagan, Essel; Van Buskirk, Robert; Ofosu-Ahenkorah, Alfred; McNeil, Michael A.

2006-02-28T23:59:59.000Z

48

Non-CFC vacuum alternatives for the energy-efficient insulation of household refrigerators: Design and use  

Science Conference Proceedings (OSTI)

Energy efficiency, environmental issues, and market incentives all encourage government and industry to continue work on thin-profile vacuum insulations for domestic refrigerators and freezers (R/Fs). Vacuum insulations promise significant improvement in thermal savings over current insulations; the technical objective of one design is an R-value of better than 10 (hr-ft{sup 2}-F/Btu) in 0.1 in. thickness. If performance is improved by a factor of 10 over that of CFC-blown insulating foams, the new insulations (made without CFCs or other potentially troublesome fill gases) will change the design and improve the efficiency of refrigerators. Such changes will meet the conservation, regulatory, and market drivers now strong in developed countries and likely to increase in developing countries. Prototypes of various designs have been tested in the laboratory and in factories, and results to date confirm the good thermal performance of these thin-profile alternatives. The next step is to resolve issues of reliability and cost effectiveness. 34 refs., 4 figs.

Potter, T.F.; Benson, D.K.

1991-01-01T23:59:59.000Z

49

Date | 1Refrigeration and Air Conditioning EMA Education and Training Date | 2Refrigeration and Air Conditioning EMA Education and Training  

E-Print Network (OSTI)

Date | 1Refrigeration and Air Conditioning EMA Education and Training #12;Date | 2Refrigeration Flow Coil Design etc. Finger Print Relationship Every evaporator is unique Unstable Region * = examples

Oak Ridge National Laboratory

50

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

.100.110.2 Typical refrigerant: R-134a, R- 600a and other hydrocarbons cture:http://1 Air-cooled condensing unit ncompressioisentropicwithprocess isentropicc realc t COP COP · The diagram gives some efficiency data from commercial vapour- 6 some efficiency data from commercial vapour compression refrigerators (T1 = TH, T2 = TL, data from 1976

Zevenhoven, Ron

51

Vaccine refrigerator testing. Final report  

SciTech Connect

For the Central American Health Clinic Project initiated in 1986, Sandia National Laboratories and the Florida Solar Energy Center recognized the need for a test and evaluation program for vaccine refrigeration systems. At the Florida Solar Energy Center, side-by-side testing of three photovoltaic powered vaccine refrigerators began in 1987. The testing was expanded in 1988 to include a kerosene absorption refrigerator. This report presents observations, conclusions, and recommendations derived from testing the four vaccine refrigeration systems. Information is presented pertaining to the refrigerators, photovoltaic arrays, battery subsystems, charge controllers, and user requirements. This report should be of interest to designers, manufacturers, installers, and users of photovoltaic-powered vaccine refrigeration systems and components.

Ventre, G.G. [Univ. of Central Florida, Orlando, FL (United States); Kilfoyle, D.; Marion, B. [Florida Solar Energy Center, Cape Canaveral, FL (United States)

1990-06-01T23:59:59.000Z

52

Design and characterization of an UHV compatible artificial channel cut monochromator.  

SciTech Connect

We present design and characterization results of a novel ultra-high-vacuum-compatible artificial channel-cut monochromator that has been installed at the undulator beamline 8-ID-I at the Advanced Photon Source. The monochromator has been designed to meet the challenging stability and optical requirements of the x-ray photon correlation spectroscopy program hosted at this beamline. In particular, the device incorporates a novel in-vacuum sine-bar drive mechanism for the combined pitch motion of the two crystals and a flexure-based high-stiffness weak-link mechanism for fine tuning the pitch and roll of the second crystal relative to the first crystal.

Narayanan, S.; Shu, D.; Sandy, A.; Sprung, M.; Preissner, C.; Sullivan, J.; X-Ray Science Division

2006-01-01T23:59:59.000Z

53

NRELs Energy-Saving Technology for Air Conditioning Cuts Peak Power Loads Without Using Harmful Refrigerants (Fact Sheet), NREL (National Renewable Energy Laboratory)  

NLE Websites -- All DOE Office Websites (Extended Search)

DEVAP Slashes Peak Power Loads DEVAP Slashes Peak Power Loads Desiccant-enhanced evaporative (DEVAP) air-condi- tioning will provide superior comfort for commercial buildings in any climate at a small fraction of the elec- tricity costs of conventional air-conditioning equip- ment, releasing far less carbon dioxide and cutting costly peak electrical demand by an estimated 80%. Air conditioning currently consumes about 15% of the electricity generated in the United States and is a major contributor to peak electrical demand on hot summer days, which can lead to escalating power costs, brownouts, and rolling blackouts. DEVAP employs an innovative combination of air-cooling technologies to reduce energy use by up to 81%. DEVAP also shifts most of the energy needs to thermal energy sources, reducing annual electricity use by up

54

Frontiers in thermoacoustic refrigeration and mixture separation  

E-Print Network (OSTI)

pulse-tube refrigerator shown in Figure 1 dissipates acoustic power by design because power must flowFrontiers in thermoacoustic refrigeration and mixture separation S. Backhaus1 , D. Geller2 , B oscillating thermodynamics in a gas in a sealed system. Since then, many related engines and refrigerators

55

ARTI Refrigerant Database  

SciTech Connect

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern. The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air-conditioning and refrigeration equipment. The complete documents are not included. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R-717 (ammonia), ethers, and others as well as azeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents addressing compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. Incomplete citations or abstracts are provided for some documents to accelerate availability of the information and will be completed or replaced in future updates.

Cain, J.M. (Calm (James M.), Great Falls, VA (United States))

1993-04-30T23:59:59.000Z

56

Japanese refrigerators field testing  

SciTech Connect

Residential refrigerators consume the equivalent of 1700 megawatts (MW) of baseload power in the Bonneville Power Administration (BPA) service area. Japanese manufacturers have designed refrigerator units that appear more energy efficient than some currently available American models. This report summarizes preliminary findings from field testing of 12 refrigerators of Japanese manufacture to evaluate annual kilowatt hour (kWh) use during actual operation. The units have also undergone laboratory testing sponsored by BPA at ETL Testing Laboratories, Inc. in Cortland, New York. A final report of the project -- due at the end of 1989 -- will correlate in detail the results of field and laboratory tests in comparison to performance ratings determined by the manufacturer.

Lou, A.T.

1989-03-01T23:59:59.000Z

57

Adsorption Refrigeration System  

SciTech Connect

Adsorption refrigeration is an environmentally friendly cooling technology which could be driven by recovered waste heat or low-grade heat such as solar energy. In comparison with absorption system, an adsorption system has no problems such as corrosion at high temperature and salt crystallization. In comparison with vapor compression refrigeration system, it has the advantages of simple control, no moving parts and less noise. This paper introduces the basic theory of adsorption cycle as well as the advanced adsorption cycles such as heat and mass recovery cycle, thermal wave cycle and convection thermal wave cycle. The types, characteristics, advantages and drawbacks of different adsorbents used in adsorption refrigeration systems are also summarized. This article will increase the awareness of this emerging cooling technology among the HVAC engineers and help them select appropriate adsorption systems in energy-efficient building design.

Wang, Kai [ORNL; Vineyard, Edward Allan [ORNL

2011-01-01T23:59:59.000Z

58

Japanese Refrigerators Field Testing.  

SciTech Connect

Residential refrigerators consume the equivalent of 1700 megawatts (MW) of baseload power in the Bonneville Power Administration (BPA) service area. Japanese manufacturers have designed refrigerator units that appear more energy efficient than some currently available American models. This report summarizes preliminary findings from field testing of 12 refrigerators of Japanese manufacture to evaluate annual kilowatt hour (kWh) use during actual operation. The units have also undergone laboratory testing sponsored by BPA at ETL Testing Laboratories, Inc. in Cortland, New York. A final report of the project -- due at the end of 1989 -- will correlate in detail the results of field and laboratory tests in comparison to performance ratings determined by the manufacturer.

Lou, Albert T.

1989-03-01T23:59:59.000Z

59

ARTI Refrigerant Database  

Science Conference Proceedings (OSTI)

The database provides bibliographic citations and abstracts for publications that may be useful in research and design of air- conditioning and refrigeration equipment. The database identifies sources of specific information on R-32, R-123, R-124, R-125, R-134, R-134a, R-141b, R-142b, R-143a, R-152a, R-245ca, R-290 (propane), R- 717 (ammonia), ethers, and others as well as azeotropic and zeotropic and zeotropic blends of these fluids. It addresses lubricants including alkylbenzene, polyalkylene glycol, ester, and other synthetics as well as mineral oils. It also references documents on compatibility of refrigerants and lubricants with metals, plastics, elastomers, motor insulation, and other materials used in refrigerant circuits. A computerized version is available that includes retrieval software.

Calm, J.M.

1992-11-09T23:59:59.000Z

60

Kylteknik ("KYL")Kylteknik ("KYL") RefrigerationRefrigerationRefrigerationRefrigeration  

E-Print Network (OSTI)

) and gives it off at higher ail.asp?article temperature (and pressure) and gives it off at higher temperature or no pressure changes Coolant for an engine: e:http://www 8.11.2012?bo Akademi Univ - Thermal and Flow Engineering - Piispankatu 8, 20500 Turku 32/64 pressure changes. Coolant for an engine: not a refrigerant

Zevenhoven, Ron

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Multi-stage Cascaded Stirling Refrigerator  

NLE Websites -- All DOE Office Websites (Extended Search)

have developed a multi-stage refrigerator, designed to recapture and utilize the acoustic energy that would ordinarily be wasted in traditional Stirling configurations. Available...

62

Magnetic Refrigeration a 21 - Programmaster.org  

Science Conference Proceedings (OSTI)

Presentation Title, Magnetic Refrigeration a 21st Century Highly Efficient and Green ... Alloy Design and Powder Processing of Mn-Al Based Materials for Rare

63

The Cost of Helium Refrigerators and Coolers for Superconducting Devices as a Function of Cooling at 4 K  

E-Print Network (OSTI)

as a function of design refrigeration at 4.5 K. The costsk$) versus the Design Refrigeration at 4.2 K (W) THECoolers versus the Design Refrigeration at 4.2 K. (The open

Green, Michael A.

2008-01-01T23:59:59.000Z

64

Refrigerant directly cooled capacitors  

DOE Patents (OSTI)

The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.

Hsu, John S. (Oak Ridge, TN); Seiber, Larry E. (Oak Ridge, TN); Marlino, Laura D. (Oak Ridge, TN); Ayers, Curtis W. (Kingston, TN)

2007-09-11T23:59:59.000Z

65

Fluorescent refrigeration  

DOE Patents (OSTI)

Fluorescent refrigeration is based on selective radiative pumping, using substantially monochromatic radiation, of quantum excitations which are then endothermically redistributed to higher energies. Ultimately, the populated energy levels radiatively deexcite emitting, on the average, more radiant energy than was initially absorbed. The material utilized to accomplish the cooling must have dimensions such that the exciting radiation is strongly absorbed, but the fluorescence may exit the material through a significantly smaller optical pathlength. Optical fibers and mirrored glasses and crystals provide this requirement. 6 figs.

Epstein, R.I.; Edwards, B.C.; Buchwald, M.I.; Gosnell, T.R.

1995-09-05T23:59:59.000Z

66

Candidate chemical systems for air cooled, solar powered, absorption air conditioner design. Part II. Solid absorbents, high latent heat refrigerants  

DOE Green Energy (OSTI)

Work done in attempting to qualify absorption refrigeration systems based on refrigerants with intermediate latent heats of vaporization is summarized. In practice, these comprise methanol, ammonia, and methylamine. A wide variety of organic substances, salts, and mixtures were evaluated in as systematic a manner as possible. Several systems of interest are described. The system, LiClO/sub 3/--LiBr--H/sub 2/O, is a good back up system to our first choice of an antifreeze additive system, and thermodynamically promising but subject to some inconvenient materials limitations. The system, LiBr/ZnBr/sub 2/--methanol, is thermodynamically promising but requires additional kinetic qualification. Chemical stability of the system, LiCNS--ammonia/methylamine with various other third components, does not appear to be adequate for a long-lived system.

Biermann, W. J.

1978-04-01T23:59:59.000Z

67

Integrating giant microwave absorption with magnetic refrigeration in one  

E-Print Network (OSTI)

Integrating giant microwave absorption with magnetic refrigeration in one multifunctional with magnetic refrigeration in one multifunctional material. This integration not only advances our EMI problem, it is becoming very urgent to design and fabricate the electromagnetic compatibility (EMC

Wang, Wei Hua

68

Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Thermodynamic Evaluation of Thermodynamic Evaluation of Low-GWP Refrigerants Mark O. McLinden National Institute of Standards and Technology markm@boulder.nist.gov; 303-497-3580 April 3, 2013 Optimization Fluid Modeling Cycle Modeling Final Candidates Optimum Thermo Parameters 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: HFC refrigerants face restrictions: U.S./Canada/Mexico proposal to Montreal Protocol (85 % cut) EU regulations likely on all application areas (79 % cut)

69

Thermodynamic Evaluation of Low-Global Warming Potential Refrigerants  

NLE Websites -- All DOE Office Websites (Extended Search)

Thermodynamic Evaluation of Thermodynamic Evaluation of Low-GWP Refrigerants Mark O. McLinden National Institute of Standards and Technology markm@boulder.nist.gov; 303-497-3580 April 3, 2013 Optimization Fluid Modeling Cycle Modeling Final Candidates Optimum Thermo Parameters 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: HFC refrigerants face restrictions: U.S./Canada/Mexico proposal to Montreal Protocol (85 % cut) EU regulations likely on all application areas (79 % cut)

70

Compatibility of refrigerants and lubricants with elastomers  

SciTech Connect

Information contained in this reporters designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. Swell measurements have been made on approximately 50% of the proposed elastomers (94 total)in both the lubricant (7 total) and refrigerant (10 total) materials. Swell behavior in the these fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1992-07-01T23:59:59.000Z

71

High Efficiency Low Emission Supermarket Refrigeration Research Project |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

High Efficiency Low Emission Supermarket High Efficiency Low Emission Supermarket Refrigeration Research Project High Efficiency Low Emission Supermarket Refrigeration Research Project The U.S. Department of Energy (DOE) is currently conducting research into high efficiency, low emission supermarket refrigeration technologies. Project Description The project involves the development of a supermarket refrigeration system that can reduce greenhouse gas emissions and energy consumption when compared to existing systems. The challenge is to design a system that is capable of achieving low refrigerant leak rates while significantly reducing both the energy consumption and the refrigerant charge size. Project Partners Research is being undertaken between DOE and Oak Ridge National Laboratory. Project Goals

72

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M.

1996-07-01T23:59:59.000Z

73

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilities access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)] [Calm (James M.), Great Falls, VA (United States)

1999-01-01T23:59:59.000Z

74

ARTI refrigerant database  

Science Conference Proceedings (OSTI)

The Refrigerant Database is an information system on alternative refrigerants, associated lubricants, and their use in air conditioning and refrigeration. It consolidates and facilitates access to property, compatibility, environmental, safety, application and other information. It provides corresponding information on older refrigerants, to assist manufacturers and those using alternative refrigerants, to make comparisons and determine differences. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M.

1996-11-15T23:59:59.000Z

75

HANDLING FRESH FISH REFRIGERATION OF FISH -PART 2  

E-Print Network (OSTI)

(Fishery Leaflet 427) Cold-Storage Design and Refrigeration Equipment Part 3 (Fisher y Leaflet 429) FactorsHANDLING FRESH FISH REFRIGERATION OF FISH - PART 2 UNITED STATES DEPARTMENT OF THE INTERIOR FISH 428 Washington 25, D, C. December 1956 REFRIGERATION OF FISH - PART TWO HANDLING FRESH FISH By Charles

76

Superinsulation in refrigerators and freezers  

SciTech Connect

The results presented here were obtained during Phase 4 of the first CRADA, which had the specific objective of determining the lifetime of superinsulations when installed in simulated refrigerator doors. The second CRADA was established to evaluate and test design concepts proposed to significantly reduce energy consumption in a refrigerator-freezer that is representative of approximately 60% of the US market. The stated goal of this CRADA is to demonstrate advanced technologies which reduce, by 50%, the 1993 National Appliance Energy Conservation Act (NAECA) standard energy consumption for a 20 ft{sup 3} (570 L) top-mount, automatic-defrost, refrigerator-freezer. For a unit this size, the goal translates to an energy consumption of 1.003 kWh/d. The general objective of the research is to facilitate the introduction of efficient appliances by demonstrating design changes that can be effectively incorporated into new products. In previous work on this project, a Phase 1 prototype refrigerator-freezer achieved an energy consumption of 1.413 kWh/d [Vineyard, et al., 1995]. Following discussions with an advisory group comprised of all the major refrigerator-freezer manufacturers, several options were considered for the Phase 2 effort, one of which was cabinet heat load reductions.

Vineyard, E.; Stovall, T.K.; Wilkes, K.E.; Childs, K.W.

1998-02-01T23:59:59.000Z

77

Japanese Refrigerators : A Field Performance Analysis : Summary Report.  

SciTech Connect

Society generally expects Japanese refrigerators to be more energy efficient than their American-made counterparts. With increasing attention being focused on appliance energy efficiency, research into operating characteristics of Japanese refrigerators has gained importance. Other projects report the monitored energy use of certain models of Japanese refrigerators. In addition, laboratory tests determined energy consumption of certain refrigerators under controlled conditions. In 1987, Bonneville Power Administration (BPA) undertook a project to measure and analyze the energy consumption of 12 Japanese-made refrigerators in the Portland-Vancouver metropolitan area. This project's purpose was to collect field data on certain models and compare with that collected in other projects and laboratory tests. Japanese energy consumption figures fall 30--40% below those of DOE. This energy savings, if real, could substantially cut baseload power for utilities. Determining typical refrigerator energy use patterns and which environmental factors effect them helps utilities to forecast demand. 7 refs., 1 fig., 1 tab.

Short, John A.

1990-02-01T23:59:59.000Z

78

ARTI Refrigerant Database  

Science Conference Proceedings (OSTI)

The Refrigerant Database consolidates and facilitates access to information to assist industry in developing equipment using alternative refrigerants. The underlying purpose is to accelerate phase out of chemical compounds of environmental concern.

Calm, J.M. [Calm (James M.), Great Falls, VA (United States)

1994-05-27T23:59:59.000Z

79

Compatibility of refrigerants and lubricants with elastomers  

Science Conference Proceedings (OSTI)

The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on availability of additional R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1993-01-01T23:59:59.000Z

80

Compatibility of refrigerants and lubricants with elastomers  

Science Conference Proceedings (OSTI)

Information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on the availability of additional quantities of R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1992-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Magnetocaloric Refrigeration Concepts: Current State of the Art  

Science Conference Proceedings (OSTI)

Abstract Scope, Refrigeration devices based on the magnetocaloric effect have been ... Some of the major design choices are then evaluated and, based on...

82

Refrigerator Efficiency in Ghana: Tailoring an Appliance Market...  

NLE Websites -- All DOE Office Websites (Extended Search)

Refrigerator Efficiency in Ghana: Tailoring an Appliance Market Transformation Program Design for Africa Publication Type Report LBNL Report Number LBNL-61251 Year of...

83

Enhancement of the Refrigerant Capacity in Partially Crystallized Gd ...  

Science Conference Proceedings (OSTI)

Consequently, the magnetic refrigerant capacity of the partially crystallized alloys is ... Alloy Design and Powder Processing of Mn-Al Based Materials for Rare...

84

Novel La(Fe,Si) 13 -Based Composites for Magnetic Refrigeration  

Science Conference Proceedings (OSTI)

Nanocomposite Alloy Design for High Frequency Power Conversion Applications Novel La(Fe,Si)13-Based Composites for Magnetic Refrigeration.

85

Chapter 11, Sample Design Cross-Cutting Protocols: The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: Sample Design 1: Sample Design Cross-Cutting Protocols M. Sami Khawaja, Josh Rushton, and Josh Keeling, The Cadmus Group, Inc. Subcontract Report NREL/SR-7A30-53827 April 2013 The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures 11 - 1 Chapter 11 - Table of Contents 1 Introduction ............................................................................................................................ 3 1.1 Chapter Organization ....................................................................................................... 3 2 Overview ................................................................................................................................ 5 2.1 Sampling and Sample Design .......................................................................................... 5

86

Regenerator for Magnetic Refrigerants  

Ames Laboratory researchers have developed a new magnetic material that can be used at low temperatures (sub liquid hydrogen) for magnetic refrigerators.

87

China Refrigerator Information Label  

E-Print Network (OSTI)

LBNL-246E China Refrigerator Information Label: Specification Development and Potential Impact Jianhong Cheng China National Institute of Standardization Tomoyuki Sakamoto The Institute of Energy

88

A compact rotating dilution refrigerator  

E-Print Network (OSTI)

We describe the design and performance of a new rotating dilution refrigerator that will primarily be used for investigating the dynamics of quantized vortices in superfluid 4He. All equipment required to operate the refrigerator and perform experimental measurements is mounted on two synchronously driven, but mechanically decoupled, rotating carousels. The design allows for relative simplicity of operation and maintenance and occupies a minimal amount of space in the laboratory. Only two connections between the laboratory and rotating frames are required for the transmission of electrical power and helium gas recovery. Measurements on the stability of rotation show that rotation is smooth to around 0.001 rad/s up to angular velocities in excess of 2.5 rad/s. The behavior of a high-Q mechanical resonator during rapid changes in rotation has also been investigated.

Fear, M J; Chorlton, D A; Zmeev, D E; Gillott, S J; Sellers, M C; Richardson, P P; Agrawal, H; Batey, G; Golov, A I

2013-01-01T23:59:59.000Z

89

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-11-24T23:59:59.000Z

90

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer (11) at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer (11) to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator (10) to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing he evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator.

Vobach, Arnold R. (6006 Allentown Dr., Spring, TX 77379)

1987-01-01T23:59:59.000Z

91

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer (11) at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer (11) to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator (10) to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator.

Vobach, Arnold R. (6006 Allentown Dr., Spring, TX 77389)

1987-01-01T23:59:59.000Z

92

Chemically assisted mechanical refrigeration process  

DOE Patents (OSTI)

There is provided a chemically assisted mechanical refrigeration process including the steps of: mechanically compressing a refrigerant stream which includes vaporized refrigerant; contacting the refrigerant with a solvent in a mixer at a pressure sufficient to promote substantial dissolving of the refrigerant in the solvent in the mixer to form a refrigerant-solvent solution while concurrently placing the solution in heat exchange relation with a working medium to transfer energy to the working medium, said refrigerant-solvent solution exhibiting a negative deviation from Raoult's Law; reducing the pressure over the refrigerant-solvent solution in an evaporator to allow the refrigerant to vaporize and substantially separate from the solvent while concurrently placing the evolving refrigerant-solvent solution in heat exchange relation with a working medium to remove energy from the working medium to thereby form a refrigerant stream and a solvent stream; and passing the solvent and refrigerant stream from the evaporator. 5 figs.

Vobach, A.R.

1987-06-23T23:59:59.000Z

93

Embedded Smart Controller for an Industrial Reefer Refrigeration1  

E-Print Network (OSTI)

refrigeration control. The goal of this project is twofold: to design an efficient and economically feasibleEmbedded Smart Controller for an Industrial Reefer Refrigeration1 Leon Reznik and Shane Spiteri intelligent industrial controller on one hand and to test and further develop a smart device design approach

Reznik, Leon

94

Defrost Temperature Termination in Supermarket Refrigeration Systems  

SciTech Connect

The objective of this project was to determine the potential energy savings associated with implementing demand defrost strategies to defrost supermarket refrigerated display case evaporators, as compared to the widely accepted current practice of controlling display case defrost cycles with a preset timer. The defrost heater energy use of several representative display case types was evaluated. In addition, demand defrost strategies for refrigerated display cases as well as those used in residential refrigerator/freezers were evaluated. Furthermore, it is anticipated that future work will include identifying a preferred defrost strategy, with input from Retail Energy Alliance members. Based on this strategy, a demand defrost system will be designed which is suitable for supermarket refrigerated display cases. Limited field testing of the preferred defrost strategy will be performed in a supermarket environment.

Fricke, Brian A [ORNL; Sharma, Vishaldeep [ORNL

2011-11-01T23:59:59.000Z

95

Chapter 12, Survey Design and Implementation Cross-Cutting Protocols for Estimating Gross Savings: The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Chapter 12: Survey Design and Chapter 12: Survey Design and Implementation Cross-Cutting Protocols for Estimating Gross Savings Robert Baumgartner, Tetra Tech Subcontract Report NREL/SR-7A30-53827 April 2013 The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures 12 - 1 Chapter 12 - Table of Contents 1 Introduction ............................................................................................................................ 2 2 The Total Survey Error Framework ....................................................................................... 4 2.1 TSE Framework for Evaluating Survey and Data Quality .............................................. 4 2.2 Sampling Errors ............................................................................................................... 5

96

Cutting Fluids  

Science Conference Proceedings (OSTI)

Table 6   Cutting fluids for aluminum...Table 6 Cutting fluids for aluminum Type of lubricant Principal ingredients Viscosity range Application; maintenance Relative effectiveness Necessary precautions Mineral oils (fatty-additive type preferred) Mineral oil, lard, or neats-foot oil; oleic acid

97

An Advanced Solar-Powered Rotary Solid Adsorption Refrigerator with High Performance  

E-Print Network (OSTI)

In this paper, according to practical consideration, a new solar powered rotary solid adsorption refrigerator system adopting activated carbon fibre + ethanol as its adsorption pair has been designed with higher performance. Moreover, the principle of the refrigeration cycle, different components of the machine, selection of working pairs and feasible theory analysis of the refrigeration system all have been presented in detail. In addition, it shows that the new refrigerator has many great advantages including a simple structure, fast refrigeration, higher thermodynamic coefficient, friendly to the atmospheric environment, etc. This paper explains that the refrigerating process is constant, which has a promising potential for competing the 'intermittent' cycle reported before. Through improving the refrigerant performance of heat and mass transfer in the adsorbent bed, the refrigeration cycle has been advanced from the aspect of utilization of the thermal energy from low-temperature level resources. In addition, it is shown that the commercial solar powered refrigerator will be existent in the near future.

Zheng, A.; Gu, J.

2006-01-01T23:59:59.000Z

98

Ground Loops for Heat Pumps and Refrigeration  

E-Print Network (OSTI)

Ground loops are used for water source heat pumps. Refrigeration can be put on a ground loop. Water-cooled condensing units are more efficient than air-cooled, and they can be put indoors. Indoor location makes piping for desuperheater hot water easy. Since refrigeration equipment runs more than heat pumps, energy savings can be large for ground-coupled refrigeration. The paper presents a design procedure for ground loops for heat pumps, hot water, ice machines, and water-cooled refrigeration. It gives an overview of the commercial ground-coupled systems in Louisiana that have both refrigeration and heat pumps. Systems vary from small offices to a three-story office building with 187 tons. A chain of hamburger outlets uses total ground-coupling in all of its stores. A grocery store has ground-coupling for heat pumps and refrigeration. Desuperheaters provide 80 percent of the hot water for a coin laundry in the same building. A comparison of energy costs in a bank with a ground-coupled heat pump system to a similar bank with air-conditioning and gas for heat revealed a 31 percent reduction in utility costs for the ground-coupled building. Two buildings of the Mississippi Power and Light Co. have ground-coupled heat pumps in one, and high efficiency air source heat pumps in the other. Energy savings in nine months was 60,000 kWh (25 percent), and electric peak demand was reduced 42 kW (35 percent).

Braud, H. J.

1986-01-01T23:59:59.000Z

99

DOE Opens Three Investigations into Alleged Refrigerator Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Opens Three Investigations into Alleged Refrigerator Efficiency Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations April 12, 2010 - 7:27pm Addthis The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that failed to meet federal energy efficiency standards. Under the subpoena, Arçelik A.S, a Turkish Company is required to submit detailed information about the design, marketing and U.S. sales of its Blomberg brand refrigerator-freezer, model "BRFB1450." The Department also requested testing data from Whirlpool Corporation and Viking Range Corporation for two refrigerator-freezers that the companies

100

DOE Opens Three Investigations into Alleged Refrigerator Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Opens Three Investigations into Alleged Refrigerator Efficiency Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations April 12, 2010 - 7:27pm Addthis The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that failed to meet federal energy efficiency standards. Under the subpoena, Arçelik A.S, a Turkish Company is required to submit detailed information about the design, marketing and U.S. sales of its Blomberg brand refrigerator-freezer, model "BRFB1450." The Department also requested testing data from Whirlpool Corporation and Viking Range Corporation for two refrigerator-freezers that the companies

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Refrigerated cryogenic envelope  

DOE Patents (OSTI)

An elongated cryogenic envelope including an outer tube and an inner tube coaxially spaced within said inner tube so that the space therebetween forms a vacuum chamber for holding a vacuum. The inner and outer tubes are provided with means for expanding or contracting during thermal changes. A shield is located in the vacuum chamber intermediate the inner and outer tubes; and, a refrigeration tube for directing refrigeration to the shield is coiled about at least a portion of the inner tube within the vacuum chamber to permit the refrigeration tube to expand or contract along its length during thermal changes within said vacuum chamber.

Loudon, John D. (Boulder, CO)

1976-11-16T23:59:59.000Z

102

Cutting assembly  

DOE Patents (OSTI)

A cutting apparatus includes a support table mounted for movement toward and away from a workpiece and carrying a mirror which directs a cutting laser beam onto the workpiece. A carrier is rotatably and pivotally mounted on the support table between the mirror and workpiece and supports a conduit discharging gas toward the point of impingement of the laser beam on the workpiece. Means are provided for rotating the carrier relative to the support table to place the gas discharging conduit in the proper positions for cuts made in different directions on the workpiece.

Racki, Daniel J. (Greensburg, PA); Swenson, Clark E. (Monroeville, PA); Bencloski, William A. (Herminie, PA); Wineman, Arthur L. (Greensburg, PA)

1984-01-01T23:59:59.000Z

103

Thermoacoustic engines and refrigerators  

SciTech Connect

This report is a transcript of a practice lecture given in preparation for a review lecture on the operation of thermoacoustic engines and refrigerators. The author begins by a brief review of the thermodynamic principles underlying the operation of thermoacoustic engines and refrigerators. Remember from thermodynamics class that there are two kinds of heat engines, the heat engine or the prime mover which produces work from heat, and the refrigerator or heat pump that uses work to pump heat. The device operates between two thermal reservoirs at temperatures T{sub hot} and T{sub cold}. In the heat engine, heat flows into the device from the reservoir at T{sub hot}, produces work, and delivers waste heat into the reservoir at T{sub cold}. In the refrigerator, work flows into the device, lifting heat Q{sub cold} from reservoir at T{sub cold} and rejecting waste heat into the reservoir at T{sub hot}.

Swift, G.

1996-12-31T23:59:59.000Z

104

REFRIGERATION OF FISH PART 5 DISTRIBUTION AND MARKETING  

E-Print Network (OSTI)

REFRIGERATION OF FISH· PART 5 DISTRIBUTION AND MARKETING OF FROZEN FISHERY PRODUCTS UNITED STATES in a series of five on "Refrigeration of Fish." Titles of the other four leaflets are: Part 1 (Fishery Leaflet 427) -- Cold-Storage Design and Refrigera- tion Equipnent Part 2 (Fishery Leaflet 428) -- Handling

105

High temperature refrigerator  

SciTech Connect

A high temperature magnetic refrigerator which uses a Stirling-like cycle in which rotating magnetic working material is heated in zero field and adiabatically magnetized, cooled in high field, then adiabatically demagnetized. During this cycle said working material is in heat exchange with a pumped fluid which absorbs heat from a low temperature heat source and deposits heat in a high temperature reservoir. The magnetic refrigeration cycle operates at an efficiency 70% of Carnot.

Steyert, Jr., William A. (Los Alamos, NM)

1978-01-01T23:59:59.000Z

106

Electric equipment providing space conditioning, water heating, and refrigeration consumes 12.5% of the nation's  

E-Print Network (OSTI)

-acceptable refrigerants. Whether involving design of specific new products or refriger- ants to which the entire industryElectric equipment providing space conditioning, water heating, and refrigeration consumes 12 are the heart of air conditioners, heat pumps, chillers, supermarket refrigeration systems, and more. Global use

Oak Ridge National Laboratory

107

Chapter 3: Refrigeration Process Control: Case Study Model 42 33.. RREEFFRRIIGGEERRAATTIIOONN PPRROOCCEESSSS  

E-Print Network (OSTI)

are needed, and the required allowances in design are made to account for this. #12;Chapter 3: RefrigerationChapter 3: Refrigeration Process Control: Case Study Model 42 33.. RREEFFRRIIGGEERRAATTIIOONN-stage refrigeration system case study. It describes in detail the mathematical model developed, highlighting

Skogestad, Sigurd

108

DOE Defends Decision to Revoke Energy Star Designation for Certain...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Defends Decision to Revoke Energy Star Designation for Certain LG Refrigerators DOE Defends Decision to Revoke Energy Star Designation for Certain LG Refrigerators December 23,...

109

Non-intrusive refrigerant charge indicator - Energy ...  

... -phase refrigerant line section. The measured temperature can be used to determine the refrigerant charge status of an HVAC system, ...

110

Demand Response Opportunities in Industrial Refrigerated Warehouses...  

NLE Websites -- All DOE Office Websites (Extended Search)

Demand Response Opportunities in Industrial Refrigerated Warehouses in California Title Demand Response Opportunities in Industrial Refrigerated Warehouses in California...

111

Potential Refrigerants for Power Electronics Cooling  

DOE Green Energy (OSTI)

In the past, automotive refrigerants have conventionally been used solely for the purpose of air conditioning. However, with the development of hybrid-electric vehicles and the incorporation of power electronics (PEs) into the automobile, automotive refrigerants are taking on a new role. Unfortunately, PEs have lifetimes and functionalities that are highly dependent on temperature and as a result thermal control plays an important role in the performance of PEs. Typically, PEs are placed in the engine compartment where the internal combustion engine (ICE) already produces substantial heat. Along with the ICE heat, the additional thermal energy produced by PEs themselves forces designers to use different cooling methods to prevent overheating. Generally, heat sinks and separate cooling loops are used to maintain the temperature. Disturbingly, the thermal control system can consume one third of the total volume and may weigh more than the PEs [1]. Hence, other avenues have been sought to cool PEs, including submerging PEs in automobile refrigerants to take advantage of two-phase cooling. The objective of this report is to explore the different automotive refrigerants presently available that could be used for PE cooling. Evaluation of the refrigerants will be done by comparing environmental effects and some thermo-physical properties important to two-phase cooling, specifically measuring the dielectric strengths of potential candidates. Results of this report will be used to assess the different candidates with good potential for future use in PE cooling.

Starke, M.R.

2005-10-24T23:59:59.000Z

112

On the performance of ejector refrigeration systems  

Science Conference Proceedings (OSTI)

The design characteristics of an ejector refrigeration system using R134a with fixed cooling capacity and fixed inlet temperatures of the external fluids at the inlet of the generator, the condenser and the evaporator are presented for different pressures ... Keywords: COP, R-134a, computer simulation, finite size thermodynamics

Abdelouahid Dahmani; Zine Aidoun; Nicolas Galanis

2010-02-01T23:59:59.000Z

113

ADVANCED CUTTINGS TRANSPORT STUDY  

SciTech Connect

This is the second quarterly progress report for Year 2 of the ACTS project. It includes a review of progress made in Flow Loop development and research during the period of time between Oct 1, 2000 and December 31, 2000. This report presents a review of progress on the following specific tasks: (a) Design and development of an Advanced Cuttings Transport Facility (Task 2: Addition of a foam generation and breaker system), (b) Research project (Task 6): ''Study of Cuttings Transport with Foam Under LPAT Conditions (Joint Project with TUDRP)'', (c) Research project (Task 7): ''Study of Cuttings Transport with Aerated Muds Under LPAT Conditions (Joint Project with TUDRP)'', (d) Research project (Task 8): ''Study of Flow of Synthetic Drilling Fluids Under Elevated Pressure and Temperature Conditions'', (e) Research project (Task 9): ''Study of Foam Flow Behavior Under EPET Conditions'', (f) Research project (Task 10): ''Study of Cuttings Transport with Aerated Mud Under Elevated Pressure and Temperature Conditions'', (g) Research on instrumentation tasks to measure: Cuttings concentration and distribution in a flowing slurry (Task 11), and Foam properties while transporting cuttings. (Task 12), (h) Development of a Safety program for the ACTS Flow Loop. Progress on a comprehensive safety review of all flow-loop components and operational procedures. (Task 1S). (i) Activities towards technology transfer and developing contacts with Petroleum and service company members, and increasing the number of JIP members. The tasks Completed During This Quarter are Task 7 and Task 8.

Troy Reed; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Gerald Kane; Mark Pickell; Len Volk; Mike Volk; Barkim Demirdal; Affonso Lourenco; Evren Ozbayoglu; Paco Vieira; Lei Zhou

2000-01-30T23:59:59.000Z

114

ADVANCED CUTTINGS TRANSPORT STUDY  

SciTech Connect

This is the fourth quarterly progress report for Year-3 of the ACTS Project. It includes a review of progress made in: (1) Flow Loop construction and development and (2) research tasks during the period of time between April 1, 2002 and June 30, 2002. This report presents a review of progress on the following specific tasks: (a) Design and development of an Advanced Cuttings Transport Facility (Task 3: Addition of a Cuttings Injection/Separation System), (b) Research project (Task 6): ''Study of Cuttings Transport with Foam Under LPAT Conditions (Joint Project with TUDRP)''; (c) Research project (Task 9b): ''Study of Foam Flow Behavior Under EPET Conditions''; (d) Research project (Task 10): ''Study of Cuttings Transport with Aerated Mud Under Elevated Pressure and Temperature Conditions''; (e) Research on three instrumentation tasks to measure: Cuttings concentration and distribution in a flowing slurry (Task 11), Foam texture while transporting cuttings. (Task 12), and Viscosity of Foam under EPET (Task 9b); (f) Development of a Safety program for the ACTS Flow Loop. Progress on a comprehensive safety review of all flow-loop components and operational procedures. (Task 1S); (g) Activities towards technology transfer and developing contacts with Petroleum and service company members, and increasing the number of JIP members.

Troy Reed; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Mark Pickell; Len Volk; Mike Volk; Evren Ozbayoglu; Lei Zhou

2002-07-30T23:59:59.000Z

115

ADVANCED CUTTINGS TRANSPORT STUDY  

SciTech Connect

This is the second quarterly progress report for Year-4 of the ACTS Project. It includes a review of progress made in: (1) Flow Loop construction and development and (2) research tasks during the period of time between October 1, 2002 and December 30, 2002. This report presents a review of progress on the following specific tasks. (a) Design and development of an Advanced Cuttings Transport Facility Task 3: Addition of a Cuttings Injection/Separation System, Task 4: Addition of a Pipe Rotation System. (b) New research project (Task 9b): ''Development of a Foam Generator/Viscometer for Elevated Pressure and Elevated Temperature (EPET) Conditions''. (d) Research project (Task 10): ''Study of Cuttings Transport with Aerated Mud Under Elevated Pressure and Temperature Conditions''. (e) Research on three instrumentation tasks to measure: Cuttings concentration and distribution in a flowing slurry (Task 11), Foam texture while transporting cuttings. (Task 12), and Viscosity of Foam under EPET (Task 9b). (f) New Research project (Task 13): ''Study of Cuttings Transport with Foam under Elevated Pressure and Temperature Conditions''. (g) Development of a Safety program for the ACTS Flow Loop. Progress on a comprehensive safety review of all flow-loop components and operational procedures. (Task 1S). (h) Activities towards technology transfer and developing contacts with Petroleum and service company members, and increasing the number of JIP members.

Troy Reed; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Mark Pickell; Len Volk; Mike Volk; Lei Zhou; Zhu Chen; Crystal Redden; Aimee Washington

2003-01-30T23:59:59.000Z

116

ADVANCED CUTTINGS TRANSPORT STUDY  

Science Conference Proceedings (OSTI)

This is the third quarterly progress report for Year 3 of the ACTS Project. It includes a review of progress made in: (1) Flow Loop construction and development and (2) research tasks during the period of time between Jan. 1, 2002 and Mar. 31, 2002. This report presents a review of progress on the following specific tasks: (a) Design and development of an Advanced Cuttings Transport Facility (Task 3: Addition of a Cuttings Injection/Separation System), (b) Research project (Task 6): ''Study of Cuttings Transport with Foam Under LPAT Conditions (Joint Project with TUDRP)'', (c) Research project (Task 9b): ''Study of Foam Flow Behavior Under EPET Conditions'', (d) Research project (Task 10): ''Study of Cuttings Transport with Aerated Mud Under Elevated Pressure and Temperature Conditions'', (e) Research on three instrumentation tasks to measure: Cuttings concentration and distribution in a flowing slurry (Task 11), Foam texture while transporting cuttings. (Task 12), and Viscosity of Foam under EPET (Task 9b); (f) Development of a Safety program for the ACTS Flow Loop, progress on a comprehensive safety review of all flow-loop components and operational procedures. (Task 1S); and (g) Activities towards technology transfer and developing contacts with Petroleum and service company members, and increasing the number of JIP members.

Troy Reed; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Mark Pickell; Len Volk; Mike Volk; Evren Ozbayoglu; Lei Zhou

2002-04-30T23:59:59.000Z

117

ADVANCED CUTTINGS TRANSPORT STUDY  

Science Conference Proceedings (OSTI)

This is the second quarterly progress report for Year 3 of the ACTS project. It includes a review of progress made in: (1) Flow Loop development and (2) research tasks during the period of time between Oct 1, 2001 and Dec. 31, 2001. This report presents a review of progress on the following specific tasks: (a) Design and development of an Advanced Cuttings Transport Facility (Task 3: Addition of a Cuttings Injection/Collection System), (b) Research project (Task 6): ''Study of Cuttings Transport with Foam Under LPAT Conditions (Joint Project with TUDRP)'', (c) Research project (Task 9): ''Study of Foam Flow Behavior Under EPET Conditions'', (d) Research project (Task 10): ''Study of Cuttings Transport with Aerated Mud Under Elevated Pressure and Temperature Conditions'', (e) Research on instrumentation tasks to measure: Cuttings concentration and distribution in a flowing slurry (Task 11), and Foam properties while transporting cuttings. (Task 12), (f) Development of a Safety program for the ACTS Flow Loop. Progress on a comprehensive safety review of all flow-loop components and operational procedures. (Task 1S). (g) Activities towards technology transfer and developing contacts with Petroleum and service company members, and increasing the number of JIP members.

Troy Reed; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Gerald Kane; Mark Pickell; Len Volk; Mike Volk; Affonso Lourenco; Evren Ozbayoglu; Lei Zhou

2002-01-30T23:59:59.000Z

118

Proceedings: Commercial Refrigeration Research Workshop  

Science Conference Proceedings (OSTI)

Improving refrigeration systems for commercial use can enhance both utility load factors and supermarket profits. This workshop has pinpointed research needs in commercial refrigeration and systems integration for a supermarket environment.

1984-10-01T23:59:59.000Z

119

Solar powered refrigeration apparatus  

SciTech Connect

Solar powered refrigeration apparatus is disclosed in which an absorption refrigeration system is operated directly by solar energy. One end of a heat pipe is thermally connected to the boiler of the absorption refrigeration system, and a solar collector is thermally coupled to the other remote end of the heat pipe. The heat pipe is a sealed, evacuated metal tube partially filled with water. The solar collector is a double walled glass vacuum tube with a central axial opening for accommodating the remote end of the heat pipe. Heat energy collected by the solar collector boils the water in the heat pipe to subsequently condense in the area of the boiler thus transferring heat energy along the heat pipe to the boiler. The heat pipe is installed sloping downwardly away from the boiler to permit the return of condensate down the pipe to the solar collector area thus permitting continuous operation.

Theakston, F.H.

1982-12-07T23:59:59.000Z

120

Refrigerator recycling and CFCs  

SciTech Connect

Utility-sponsored refrigerator and freezer pick-up programs have removed almost 900,000 inefficient appliances from the North American electric grid to date. While the CFC-12 refrigerant from the discarded appliances is typically removed and recycled, in all but a few programs the CFC-11 in the foam insulation is not. About a quarter-billion pounds of CFC-11 are banked in refrigerator foam in the United States. Release of this ``bank`` of CFC, combined with that from foam insulation used in buildings, will be the largest source of future emissions if preventive measures are not taken. Methods exist to recover the CFC for reuse or to destroy it by incineration. The task of recycling or destroying the CFCs and other materials from millions of refrigerators is a daunting challenge, but one in which utilities can play a leadership role. E Source believes that utilities can profitably serve as the catalyst for public-private partnerships that deliver comprehensive refrigerator recycling. Rather than treating such efforts solely as a DSM resource acquisition, utilities could position these programs as a multifaceted service delivery that offers convenient appliance removal for homeowners, a solid waste minimization service for landfills, a source of recycled materials for industry, and a CFC recovery and/or disposal service in support of the HVAC industry and society`s atmospheric protection goals and laws. Financial mechanisms could be developed through these public-private enterprises to ensure that utilities are compensated for the extra cost of fully recycling refrigerators, including the foam CFC.

Shepard, M.; Hawthorne, W.; Wilson, A.

1994-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

ADVANCED CUTTINGS TRANSPORT STUDY  

DOE Green Energy (OSTI)

The Quarter began with installing the new drill pipe, hooking up the new hydraulic power unit, completing the pipe rotation system (Task 4 has been completed), and making the SWACO choke operational. Detailed design and procurement work is proceeding on a system to elevate the drill-string section. The prototype Foam Generator Cell has been completed by Temco and delivered. Work is currently underway to calibrate the system. Literature review and preliminary model development for cuttings transportation with polymer foam under EPET conditions are in progress. Preparations for preliminary cuttings transport experiments with polymer foam have been completed. Two nuclear densitometers were re-calibrated. Drill pipe rotation system was tested up to 250 RPM. Water flow tests were conducted while rotating the drill pipe up to 100 RPM. The accuracy of weight measurements for cuttings in the annulus was evaluated. Additional modifications of the cuttings collection system are being considered in order to obtain the desired accurate measurement of cuttings weight in the annular test section. Cutting transport experiments with aerated fluids are being conducted at EPET, and analyses of the collected data are in progress. The printed circuit board is functioning with acceptable noise level to measure cuttings concentration at static condition using ultrasonic method. We were able to conduct several tests using a standard low pass filter to eliminate high frequency noise. We tested to verify that we can distinguish between different depths of sand in a static bed of sand. We tested with water, air and a mix of the two mediums. Major modifications to the DTF have almost been completed. A stop-flow cell is being designed for the DTF, the ACTF and Foam Generator/Viscometer which will allow us to capture bubble images without the need for ultra fast shutter speeds or microsecond flash system.

Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Mengjiao Yu; Ramadan Ahmed; Mark Pickell; Len Volk; Lei Zhou; Zhu Chen; Aimee Washington; Crystal Redden

2003-09-30T23:59:59.000Z

122

Low-temperature magnetic refrigerator  

DOE Patents (OSTI)

The invention relates to magnetic refrigeration and more particularly to low temperature refrigeration between about 4 and about 20 K, with an apparatus and method utilizing a belt of magnetic material passed in and out of a magnetic field with heat exchangers within and outside the field operably disposed to accomplish refrigeration.

Barclay, J.A.

1983-05-26T23:59:59.000Z

123

ADVANCED CUTTINGS TRANSPORT STUDY  

Science Conference Proceedings (OSTI)

This is the first quarterly progress report for Year 2 of the ACTS project. It includes a review of progress made in Flow Loop development and research during the period of time between July 14, 2000 and September 30, 2000. This report presents information on the following specific tasks: (a) Progress in Advanced Cuttings Transport Facility design and development (Task 2), (b) Progress on research project (Task 8): ''Study of Flow of Synthetic Drilling Fluids Under Elevated Pressure and Temperature Conditions'', (c) Progress on research project (Task 6): ''Study of Cuttings Transport with Foam Under LPAT Conditions (Joint Project with TUDRP)'', (d) Progress on research project (Task 7): ''Study of Cuttings Transport with Aerated Muds Under LPAT Conditions (Joint Project with TUDRP)'', (e) Progress on research project (Task 9): ''Study of Foam Flow Behavior Under EPET Conditions'', (f) Initiate research on project (Task 10): ''Study of Cuttings Transport with Aerated Mud Under Elevated Pressure and Temperature Conditions'', (g) Progress on instrumentation tasks to measure: Cuttings concentration and distribution (Tasks 11), and Foam properties (Task 12), (h) Initiate a comprehensive safety review of all flow-loop components and operational procedures. Since the previous Task 1 has been completed, we will now designate this new task as: (Task 1S). (i) Activities towards technology transfer and developing contacts with Petroleum and service company members, and increasing the number of JIP members.

Troy Reed; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Gerald Kane; Mark Pickell; Len Volk; Mike Volk; Barkim Demirdal; Affonso Lourenco; Evren Ozbayoglu; Paco Vieira

2000-10-30T23:59:59.000Z

124

The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration  

Open Energy Info (EERE)

The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration and Air Conditioning Jump to: navigation, search Tool Summary LAUNCH TOOL Name: The Greenhouse Gas Protocol Initiative: GHG Emissions from Refrigeration and Air Conditioning Agency/Company /Organization: World Resources Institute, World Business Council for Sustainable Development Sector: Energy, Climate Focus Area: Greenhouse Gas Phase: Determine Baseline, Evaluate Effectiveness and Revise as Needed Resource Type: Software/modeling tools User Interface: Spreadsheet Website: www.ghgprotocol.org/calculation-tools/all-tools Cost: Free References: Refrigerant Guide[1] The Greenhouse Gas Protocol tool for refrigeration is a free Excel spreadsheet calculator designed to calculate GHG emissions specifically

125

Design and performance of an ultra-high vacuum scanning tunneling microscope operating at dilution refrigerator temperatures and high magnetic fields  

E-Print Network (OSTI)

We describe the construction and performance of a scanning tunneling microscope (STM) capable of taking maps of the tunneling density of states with sub-atomic spatial resolution at dilution refrigerator temperatures and high (14 T) magnetic fields. The fully ultra-high vacuum system features visual access to a two-sample microscope stage at the end of a bottom-loading dilution refrigerator, which facilitates the transfer of in situ prepared tips and samples. The two-sample stage enables location of the best area of the sample under study and extends the experiment lifetime. The successful thermal anchoring of the microscope, described in detail, is confirmed through a base temperature reading of 20 mK, along with a measured electron temperature of 250 mK. Atomically-resolved images, along with complementary vibration measurements, are presented to confirm the effectiveness of the vibration isolation scheme in this instrument. Finally, we demonstrate that the microscope is capable of the same level of perform...

Misra, Shashank; Drozdov, Ilya K; Seo, Jungpil; Gyenis, Andras; Kingsley, Simon C J; Jones, Howard; Yazdani, Ali

2013-01-01T23:59:59.000Z

126

Preliminary selection of refrigerants for dual-circuit and Lorenz refrigerator/freezers  

SciTech Connect

The paper discusses the preliminary selection of refrigerants for dual-circuit and Lorenz refrigerator/freezers (RFs). Since RFs currently use a fully halogenated chlorofluorocarbon (CFC) as a refrigerant and are the most energy-consuming appliances in most households in the U.S., EPA is concerned about not only RFs' effects on stratospheric ozone depletion but also their impact on the greenhouse effect. Reductions in power consumption will slow the increase in carbon dioxide (CO{sub 2}) concentrations in the atmosphere by reducing the utility companies' need for capacity. CO{sub 2} concentrations are believed to be directly related to impacts of the greenhouse effect. For these reasons, EPA believes that finding the most energy-efficient refrigerant(s) and RF design is important when eliminating fully halogenated CFCs. Two new configurations (the dual-circuit and Lorenz RFs) appear to provide energy savings of up to 20% over standard U.S. RF designs.

Bare, J.C.

1990-01-01T23:59:59.000Z

127

ADVANCED CUTTINGS TRANSPORT STUDY  

DOE Green Energy (OSTI)

This report includes a review of the progress made in ACTF Flow Loop development and research during 90 days pre-award period (May 15-July 14, 1999) and the following three months after the project approval date (July15-October 15, 1999) The report presents information on the following specific subjects; (a) Progress in Advanced Cuttings Transport Facility design and development, (b) Progress report on the research project ''Study of Flow of Synthetic Drilling Fluids Under Elevated Pressure and Temperature Conditions'', (c) Progress report on the research project ''Study of Cuttings Transport with Foam Under LPAT Conditions (Joint Project with TUDRP)'', (d) Progress report on the research project ''Study of Cuttings Transport with Aerated Muds Under LPAT Conditions (Joint Project with TUDRP)'', (e) Progress report on the research project ''Study of Foam Flow Behavior Under EPET Conditions'', (f) Progress report on the instrumentation tasks (Tasks 11 and 12) (g) Activities towards technology transfer and developing contacts with oil and service company members.

Ergun Kuru; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Gerald Kane; Len Volk; Mark Pickell; Evren Ozbayoglu; Barkim Demirdal; Paco Vieira; Affonso Lourenco

1999-10-15T23:59:59.000Z

128

ADVANCED CUTTINGS TRANSPORT STUDY  

SciTech Connect

This is the first quarterly progress report for Year-4 of the ACTS Project. It includes a review of progress made in: (1) Flow Loop construction and development and (2) research tasks during the period of time between July 1, 2002 and Sept. 30, 2002. This report presents a review of progress on the following specific tasks: (a) Design and development of an Advanced Cuttings Transport Facility Task 3: Addition of a Cuttings Injection/Separation System, Task 4: Addition of a Pipe Rotation System, (b) New Research project (Task 9b): ''Development of a Foam Generator/Viscometer for Elevated Pressure and Elevated Temperature (EPET) Conditions'', (d) Research project (Task 10): ''Study of Cuttings Transport with Aerated Mud Under Elevated Pressure and Temperature Conditions'', (e) Research on three instrumentation tasks to measure: Cuttings concentration and distribution in a flowing slurry (Task 11), Foam texture while transporting cuttings (Task 12), Viscosity of Foam under EPET (Task 9b). (f) Development of a Safety program for the ACTS Flow Loop. Progress on a comprehensive safety review of all flow-loop components and operational procedures. (Task 1S). (g) Activities towards technology transfer and developing contacts with Petroleum and service company members, and increasing the number of JIP members.

Troy Reed; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Mark Pickell; Len Volk, Mike Volk; Lei Zhou; Zhu Chen; Crystal Redden; Aimee Washington

2002-10-30T23:59:59.000Z

129

Energy Efficiency and Environmental Impact Analyses of Supermarket Refrigeration Systems  

SciTech Connect

This paper presents energy and life cycle climate performance (LCCP) analyses of a variety of supermarket refrigeration systems to identify designs that exhibit low environmental impact and high energy efficiency. EnergyPlus was used to model refrigeration systems in a variety of climate zones across the United States. The refrigeration systems that were modeled include the traditional multiplex DX system, cascade systems with secondary loops and the transcritical CO2 system. Furthermore, a variety of refrigerants were investigated, including R-32, R-134a, R-404A, R-1234yf, R-717, and R-744. LCCP analysis was used to determine the direct and indirect carbon dioxide emissions resulting from the operation of the various refrigeration systems over their lifetimes. Our analysis revealed that high-efficiency supermarket refrigeration systems may result in up to 44% less energy consumption and 78% reduced carbon dioxide emissions compared to the baseline multiplex DX system. This is an encouraging result for legislators, policy makers and supermarket owners to select low emission, high-efficiency commercial refrigeration system designs for future retrofit and new projects.

Fricke, Brian A [ORNL; Bansal, Pradeep [ORNL; Zha, Shitong [Hillphoenix

2013-01-01T23:59:59.000Z

130

Microcomputer Software for Refrigerant Property and Cycle Analysis Calculations  

E-Print Network (OSTI)

A microcomputer program entitled REFRIG has been developed to determine the thermodynamic properties of common refrigerants and to analyze vapor-compression refrigeration cycles. This paper describes the theoretical basis for property determination and for the cycle analysis. Validation of property calculations is discussed. A number of features are described which have been incorporated into the program to enhance its usefulness to the engineer in analyzing system performance. Two example cases are presented to illustrate the application of the program to problems in design and operation of refrigeration systems.

Bierschenk, J. L.; Strohl, S. T.; Schmidt, P. S.

1985-05-01T23:59:59.000Z

131

Compact acoustic refrigerator  

DOE Patents (OSTI)

This invention is comprised of a compact acoustic refrigeration system that actively cools components, e.g., electrical circuits, in a borehole environment. An acoustic engine includes first thermodynamic elements for generating a standing acoustic wave in a selected medium. An acoustic refrigerator includes second thermodynamic elements located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements and a relatively hot temperature at a second end of the second thermodynamic elements. A resonator volume cooperates with the first and second thermodynamic elements to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements, first heat pipes transfer heat from the heat load to the second thermodynamic elements and second heat pipes transfer heat from first and second thermodynamic elements to the borehole environment.

Bennett, G.A.

1991-12-31T23:59:59.000Z

132

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

This invention is comprised of a cryogenic refrigerator which cools a heat source by cyclically concentrating and diluting the amount of [sup 3]He in a single phase [sup 3]He/[sup 4]He solution. The [sup 3]He in superfluid [sup 4]He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid [sup 3]He at an initial concentration in superfluid [sup 4]He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of [sup 4]He while restricting passage of [sup 3]He. The [sup 3]He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

Swift, G.W.; Kotsubo, V.Y.

1991-04-02T23:59:59.000Z

133

Compact acoustic refrigerator  

DOE Patents (OSTI)

A compact acoustic refrigeration system actively cools components, e.g., electrical circuits, in a borehole environment. An acoustic engine includes first thermodynamic elements for generating a standing acoustic wave in a selected medium. An acoustic refrigerator includes second thermodynamic elements located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements and a relatively hot temperature at a second end of the second thermodynamic elements. A resonator volume cooperates with the first and second thermodynamic elements to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements, first heat pipes transfer heat from the heat load to the second thermodynamic elements and second heat pipes transfer heat from first and second thermodynamic elements to the borehole environment. 18 figs.

Bennett, G.A.

1992-11-24T23:59:59.000Z

134

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of [sup 3]He in a single phase [sup 3]He-[sup 4]He solution. The [sup 3]He in superfluid [sup 4]He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid [sup 3]He at an initial concentration in superfluid [sup 4]He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of [sup 4]He while restricting passage of [sup 3]He. The [sup 3]He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K. 12 figs.

Swift, G.W.; Kotsubo, V.Y.

1992-12-22T23:59:59.000Z

135

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

This invention is comprised of a cryogenic refrigerator which cools a heat source by cyclically concentrating and diluting the amount of {sup 3}He in a single phase {sup 3}He/{sup 4}He solution. The {sup 3}He in superfluid {sup 4}He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid {sup 3}He at an initial concentration in superfluid {sup 4}He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of {sup 4}He while restricting passage of {sup 3}He. The {sup 3}He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

Swift, G.W.; Kotsubo, V.Y.

1991-04-02T23:59:59.000Z

136

Compact acoustic refrigerator  

DOE Patents (OSTI)

A compact acoustic refrigeration system actively cools components, e.g., electrical circuits (22), in a borehole environment. An acoustic engine (12, 14) includes first thermodynamic elements (12) for generating a standing acoustic wave in a selected medium. An acoustic refrigerator (16, 26, 28) includes second thermodynamic elements (16) located in the standing wave for generating a relatively cold temperature at a first end of the second thermodynamic elements (16) and a relatively hot temperature at a second end of the second thermodynamic elements (16). A resonator volume (18) cooperates with the first and second thermodynamic elements (12, 16) to support the standing wave. To accommodate the high heat fluxes required for heat transfer to/from the first and second thermodynamic elements (12, 16), first heat pipes (24, 26) transfer heat from the heat load (22) to the second thermodynamic elements (16) and second heat pipes (28, 32) transfer heat from first and second thermodynamic elements (12, 16) to the borehole environment.

Bennett, Gloria A. (Los Alamos, NM)

1992-01-01T23:59:59.000Z

137

Superfluid thermodynamic cycle refrigerator  

DOE Patents (OSTI)

A cryogenic refrigerator cools a heat source by cyclically concentrating and diluting the amount of .sup.3 He in a single phase .sup.3 He-.sup.4 He solution. The .sup.3 He in superfluid .sup.4 He acts in a manner of an ideal gas in a vacuum. Thus, refrigeration is obtained using any conventional thermal cycle, but preferably a Stirling or Carnot cycle. A single phase solution of liquid .sup.3 He at an initial concentration in superfluid .sup.4 He is contained in a first variable volume connected to a second variable volume through a superleak device that enables free passage of .sup.4 He while restricting passage of .sup.3 He. The .sup.3 He is compressed (concentrated) and expanded (diluted) in a phased manner to carry out the selected thermal cycle to remove heat from the heat load for cooling below 1 K.

Swift, Gregory W. (Santa Fe, NM); Kotsubo, Vincent Y. (La Canada, CA)

1992-01-01T23:59:59.000Z

138

Multilayer Thermionic Refrigeration  

DOE Green Energy (OSTI)

A review is presented of our program to construct an efficient solid state refrigerator based on thermionic emission of electrons over periodic barriers in the solid. The experimental program is to construct a simple device with one barrier layer using a three layers: metal-semiconductor-metal. The theoretical program is doing calculations to determine: (i) the optimal layer thickness, and (ii) the thermal conductivity.

Mahan, G.D.

1999-08-30T23:59:59.000Z

139

COFELY Refrigeration | Rdiger Roth | European Heat Pump Summit 2013 CopyrightCOFELYDeutuschlandGmbH2009.AlleRechtevorbehalten.  

E-Print Network (OSTI)

©COFELYDeutuschlandGmbH2009.AlleRechtevorbehalten. Industrial Design #12;COFELY Refrigeration | Rüdiger Roth | European HeatCOFELY Refrigeration | Rüdiger Roth | European Heat Pump Summit 2013 Seite 1 Copyright©COFELYDeutuschlandGmbH2009.AlleRechtevorbehalten. #12;COFELY Refrigeration | Rüdiger Roth | European Heat Pump Summit 2013

Oak Ridge National Laboratory

140

Air Conditioning with Magnetic Refrigeration : An Efficient, Green Compact Cooling System Using Magnetic Refrigeration  

SciTech Connect

BEETIT Project: Astronautics is developing an air conditioning system that relies on magnetic fields. Typical air conditioners use vapor compression to cool air. Vapor compression uses a liquid refrigerant to circulate within the air conditioner, absorb the heat, and pump the heat out into the external environment. Astronautics design uses a novel property of certain materials, called magnetocaloric materials, to achieve the same result as liquid refrigerants. These magnetocaloric materials essentially heat up when placed within a magnetic field and cool down when removed, effectively pumping heat out from a cooler to warmer environment. In addition, magnetic refrigeration uses no ozone-depleting gases and is safer to use than conventional air conditioners which are prone to leaks.

None

2010-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Optimization of Industrial Refrigeration Systems  

E-Print Network (OSTI)

A computer program designed to optimize the size of an evaporative condenser in a two-stage industrial refrigeration plant was created. The program sizes both the high-stage and low-stage compressors and an evaporative condenser. Once the initial system is sized, a year long plant simulation is performed resulting in electric energy consumption profile and an exergy destruction profile for each component and for the system. The program uses actual regional hourly outside dry bulb and wet bulb temperatures for both sizing and simulation. An exergoeconomic optimization uses the results of the simulation combined with component and energy costs to optimize the condenser size such that both plant costs and energy losses are minimized.

Flack, P. J.; Sharp, M. K.; Case, M. E.; Gregory, R. W.; Case, P. L.

1995-04-01T23:59:59.000Z

142

ADVANCED CUTTINGS TRANSPORT STUDY  

DOE Green Energy (OSTI)

Experiments on the flow loop are continuing. Improvements to the software for data acquisition are being made as additional experience with three-phase flow is gained. Modifications are being made to the Cuttings Injection System in order to improve control and the precision of cuttings injection. The design details for a drill-pipe Rotation System have been completed. A US Patent was filed on October 28, 2002 for a new design for an instrument that can generate a variety of foams under elevated pressures and temperatures and then transfer the test foam to a viscometer for measurements of viscosity. Theoretical analyses of cuttings transport phenomena based on a layered model is under development. Calibrations of two nuclear densitometers have been completed. Baseline tests have been run to determine wall roughness in the 4 different tests sections (i.e. 2-in, 3-in, 4-in pipes and 5.76-in by 3.5-in annulus) of the flow loop. Tests have also been conducted with aerated fluids at EPET conditions. Preliminary experiments on the two candidate aqueous foam formulations were conducted which included rheological tests of the base fluid and foam stability reports. These were conducted after acceptance of the proposal on the Study of Cuttings Transport with Foam Under Elevated Pressure and Elevated Temperature Conditions. Preparation of a test matrix for cuttings-transport experiments with foam in the ACTF is also under way. A controller for instrumentation to measure cuttings concentration and distribution has been designed that can control four transceivers at a time. A prototype of the control circuit board was built and tested. Tests showed that there was a problem with radiated noise. AN improved circuit board was designed and sent to an external expert to verify the new design. The new board is being fabricated and will first be tested with static water and gravel in an annulus at elevated temperatures. A series of viscometer tests to measure foam properties have begun using foam generated by the Dynamic Test Facility (DTF). Investigation of techniques to measure foam quality and size, size distribution and shape of bubbles is continuing.

Troy Reed; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Mark Pickell; Len Volk; Mike Volk; Lei Zhou; Zhu Chen; Crystal Redden; Aimee Washington

2003-04-30T23:59:59.000Z

143

Magnetic Refrigeration - Programmaster.org  

Science Conference Proceedings (OSTI)

Aug 6, 2013 ... Magnetic Refrigeration a 21st Century Highly Efficient and Green Cooling .... In order to advance their incorporation in prototypes and industrial...

144

SCREW COMPRESSOR CHARACTERISTICS FOR HELIUM REFRIGERATION SYSTEMS  

SciTech Connect

The oil injected screw compressors have practically replaced all other types of compressors in modern helium refrigeration systems due to their large displacement capacity, minimal vibration, reliability and capability of handling helium's high heat of compression.At the present state of compressor system designs for helium systems, typically two-thirds of the lost input power is due to the compression system. Therefore it is important to understand the isothermal and volumetric efficiencies of these machines to help properly design these compression systems to match the refrigeration process. This presentation summarizes separate tests that have been conducted on Sullair compressors at the Superconducting Super-Collider Laboratory (SSCL) in 1993, Howden compressors at Jefferson Lab (JLab) in 2006 and Howden compressors at the Spallation Neutron Source (SNS) in 2006. This work is part of an ongoing study at JLab to understand the theoretical basis for these efficiencies and their loss

Ganni, Venkatarao; Knudsen, Peter; Creel, Jonathan; Arenius, Dana; Casagrande, Fabio; Howell, Matt

2008-03-01T23:59:59.000Z

145

ADVANCED CUTTINGS TRANSPORT STUDY  

Science Conference Proceedings (OSTI)

This Quarter has been divided between running experiments and the installation of the drill-pipe rotation system. In addition, valves and piping were relocated, and three viewports were installed. Detailed design work is proceeding on a system to elevate the drill-string section. Design of the first prototype version of a Foam Generator has been finalized, and fabrication is underway. This will be used to determine the relationship between surface roughness and ''slip'' of foams at solid boundaries. Additional cups and rotors are being machined with different surface roughness. Some experiments on cuttings transport with aerated fluids have been conducted at EPET. Theoretical modeling of cuttings transport with aerated fluids is proceeding. The development of theoretical models to predict frictional pressure losses of flowing foam is in progress. The new board design for instrumentation to measure cuttings concentration is now functioning with an acceptable noise level. The ultrasonic sensors are stable up to 190 F. Static tests with sand in an annulus indicate that the system is able to distinguish between different sand concentrations. Viscometer tests with foam, generated by the Dynamic Test Facility (DTF), are continuing.

Troy Reed; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Mark Pickell; Len Volk; Mike Volk; Lei Zhou; Zhu Chen; Crystal Redden; Aimee Washington

2003-07-30T23:59:59.000Z

146

Improving Industrial Refrigeration System Efficiency - Actual Applications  

E-Print Network (OSTI)

This paper discusses actual design and modifications for increased system efficiency and includes reduced chilled liquid flow during part load operation, reduced condensing and increased evaporator temperatures for reduced system head, thermosiphon cycle cooling during winter operation, compressor intercooling, direct refrigeration vs. brine cooling, insulation of cold piping to reduce heat gain, multiple screw compressors for improved part load operation, evaporative condensers for reduced system head and pumping energy, and using high efficiency motors.

White, T. L.

1980-01-01T23:59:59.000Z

147

Improving the energy efficiency of refrigerators in India  

Science Conference Proceedings (OSTI)

Five state-of-the-art, production refrigerators from different manufacturers in India were subjected to a variety of appliance rating and performance evaluation test procedures in an engineering laboratory. Cabinet heat loss, compressor calorimeter, high-ambient pull-down, and closed-door energy consumption tests were performed on each unit to assess the current status of commercially available Indian refrigerators and refrigerator component efficiencies. Daily energy consumption tests were performed at nominal line voltages and at 85% and 115% of nominal voltage to assess the effect of grid voltage variations. These test results were also used to indicate opportunities for effective improvements in energy efficiency. A widely distributed ``generic`` computer model capable of simulating single-door refrigerators with a small interior freezer section was used to estimate cabinet heat loss rates and closed door energy consumption values from basic cabinet and refrigeration circuit inputs. This work helped verify the model`s accuracy and potential value as a tool for evaluating the energy impact of proposed design options. Significant differences ranging from 30 to 90% were seen in the measured performance criterion for these ``comparable`` refrigerators suggesting opportunities for improvements in individual product designs. Modeled cabinet heat loadings differed from experimentally extrapolated values in a range from 2--29%, and daily energy consumption values estimated by the model differed from laboratory data by as little as 3% or as much as 25%, which indicates that refinement of the model may be needed for this single-door refrigerator type. Additional comparisons of experimentally measured performance criteria such as % compressor run times and compressor cycling rates to modeled results are given. The computer model is used to evaluate the energy saving impact of several modest changes to the basic Indian refrigerator design.

Sand, J.R.; Vineyard, E.A. [Oak Ridge National Lab., TN (United States); Bohman, R.H. [Consulting Engineer, Cedar Rapids, IA (United States)

1995-04-01T23:59:59.000Z

148

Energy manager design for microgrids  

E-Print Network (OSTI)

refrigeration, space heating, water heating, and loads that can only be met by combustible Energy Manager Design

Firestone, Ryan; Marnay, Chris

2005-01-01T23:59:59.000Z

149

Commercial Refrigeration Equipment | Open Energy Information  

Open Energy Info (EERE)

Refrigeration Equipment Jump to: navigation, search TODO: Add description List of Commercial Refrigeration Equipment Incentives Retrieved from "http:en.openei.orgw...

150

ADVANCED CUTTINGS TRANSPORT STUDY  

Science Conference Proceedings (OSTI)

The Advanced Cuttings Transport Study (ACTS) was a 5-year JIP project undertaken at the University of Tulsa (TU). The project was sponsored by the U.S. Department of Energy (DOE) and JIP member companies. The objectives of the project were: (1) to develop and construct a new research facility that would allow three-phase (gas, liquid and cuttings) flow experiments under ambient and EPET (elevated pressure and temperature) conditions, and at different angle of inclinations and drill pipe rotation speeds; (2) to conduct experiments and develop a data base for the industry and academia; and (3) to develop mechanistic models for optimization of drilling hydraulics and cuttings transport. This project consisted of research studies, flow loop construction and instrumentation development. Following a one-year period for basic flow loop construction, a proposal was submitted by TU to the DOE for a five-year project that was organized in such a manner as to provide a logical progression of research experiments as well as additions to the basic flow loop. The flow loop additions and improvements included: (1) elevated temperature capability; (2) two-phase (gas and liquid, foam etc.) capability; (3) cuttings injection and removal system; (4) drill pipe rotation system; and (5) drilling section elevation system. In parallel with the flow loop construction, hydraulics and cuttings transport studies were preformed using drilling foams and aerated muds. In addition, hydraulics and rheology of synthetic drilling fluids were investigated. The studies were performed under ambient and EPET conditions. The effects of temperature and pressure on the hydraulics and cuttings transport were investigated. Mechanistic models were developed to predict frictional pressure loss and cuttings transport in horizontal and near-horizontal configurations. Model predictions were compared with the measured data. Predominantly, model predictions show satisfactory agreements with the measured data. As a part of this project, instrumentation was developed to monitor cuttings beds and characterize foams in the flow loop. An ultrasonic-based monitoring system was developed to measure cuttings bed thickness in the flow loop. Data acquisition software controls the system and processes the data. Two foam generating devices were designed and developed to produce foams with specified quality and texture. The devices are equipped with a bubble recognition system and an in-line viscometer to measure bubble size distribution and foam rheology, respectively. The 5-year project is completed. Future research activities will be under the umbrella of Tulsa University Drilling Research Projects. Currently the flow loop is being used for testing cuttings transport capacity of aqueous and polymer-based foams under elevated pressure and temperature conditions. Subsequently, the effect of viscous sweeps on cuttings transport under elevated pressure and temperature conditions will be investigated using the flow loop. Other projects will follow now that the ''steady state'' phase of the project has been achieved.

Stefan Miska; Troy Reed; Ergun Kuru

2004-09-30T23:59:59.000Z

151

The Proof is in the Pudding: How Refrigerator Standards Have Saved  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Proof is in the Pudding: How Refrigerator Standards Have Saved The Proof is in the Pudding: How Refrigerator Standards Have Saved Consumers $Billions The Proof is in the Pudding: How Refrigerator Standards Have Saved Consumers $Billions July 11, 2011 - 12:33pm Addthis Today’s refrigerators have been designed to save energy and money without detriment to capacity, functionality, or extra features. | Image source: Building Technologies Program Today's refrigerators have been designed to save energy and money without detriment to capacity, functionality, or extra features. | Image source: Building Technologies Program Roland Risser Roland Risser Program Director, Building Technologies Office What does this mean for me? Today's refrigerators use only about 25 percent of the energy compared to models built in 1975. They've also increased in size by almost 20 percent, with lots of

152

The Proof is in the Pudding: How Refrigerator Standards Have Saved  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

The Proof is in the Pudding: How Refrigerator Standards Have Saved The Proof is in the Pudding: How Refrigerator Standards Have Saved Consumers $Billions The Proof is in the Pudding: How Refrigerator Standards Have Saved Consumers $Billions July 11, 2011 - 12:33pm Addthis Today’s refrigerators have been designed to save energy and money without detriment to capacity, functionality, or extra features. | Image source: Building Technologies Program Today's refrigerators have been designed to save energy and money without detriment to capacity, functionality, or extra features. | Image source: Building Technologies Program Roland Risser Roland Risser Program Director, Building Technologies Office What does this mean for me? Today's refrigerators use only about 25 percent of the energy compared to models built in 1975. They've also increased in size by almost 20 percent, with lots of

153

Application of Cryocoolers to a Vintage Dilution Refrigerator  

SciTech Connect

A dilution refrigerator is required for 50mK detector operation of CDMS (Cryogenic Dark Matter Search). Besides shielding the dilution refrigerator itself, the liquid nitrogen shield and liquid helium bath in the refrigerator cool the detector cryostat heat shields and cool electronics, resulting in significant external heat loads at 80K and at 4K. An Oxford Instruments Kelvinox 400 has served this role for ten years but required daily transfers of liquid nitrogen and liquid helium. Complicating the cryogen supply is the location 800 meters below ground in an RF shielded, class 10000 clean room at Soudan, MN. Nitrogen and helium re-liquefiers using cryocoolers were installed outside the clean room and continuously condense room temperature gas and return the liquids to the dilution refrigerator through a transfer line. This paper will describe the design, installation, controls and performance of liquefaction systems.

Schmitt, Richard; Smith, Gary; Ruschman, Mark; /Fermilab; Beaty, Jim; /Minnesota U.

2011-06-06T23:59:59.000Z

154

The Cost of Superconducting Magnets as a Function of Stored Energy and Design Magnetic Induction Times the Field Volume  

E-Print Network (OSTI)

dollars and R is the design refrigeration (given in kW) atdollars and R is the design refrigeration at 4.2 K given in

Green, M.A.

2008-01-01T23:59:59.000Z

155

The 3rd International Conference of IIR on Magnetic Refrigeration at Room Temperature, Des Moines, Iowa, U.S.A, 11-15 May 2009  

E-Print Network (OSTI)

REFRIGERATION SYSTEMS USING DESIGN OF EXPERIMENTS J. ROUDAUT1,2,* , H. BOUCHEKARA1 , A. KEDOUS-LEBOUC1 , J of Design of Experiments (DOE) method in magnetic refrigeration (MR) understanding and optimizationThe 3rd International Conference of IIR on Magnetic Refrigeration at Room Temperature, Des Moines

Paris-Sud XI, Université de

156

Helium dilution refrigeration system  

DOE Patents (OSTI)

A helium dilution refrigeration system operable over a limited time period, and recyclable for a next period of operation is disclosed. The refrigeration system is compact with a self-contained pumping system and heaters for operation of the system. A mixing chamber contains [sup 3]He and [sup 4]He liquids which are precooled by a coupled container containing [sup 3]He liquid, enabling the phase separation of a [sup 3]He rich liquid phase from a dilute [sup 3]He-[sup 4]He liquid phase which leads to the final stage of a dilution cooling process for obtaining low temperatures. The mixing chamber and a still are coupled by a fluid line and are maintained at substantially the same level with the still cross sectional area being smaller than that of the mixing chamber. This configuration provides maximum cooling power and efficiency by the cooling period ending when the [sup 3]He liquid is depleted from the mixing chamber with the mixing chamber nearly empty of liquid helium, thus avoiding unnecessary and inefficient cooling of a large amount of the dilute [sup 3]He-[sup 4]He liquid phase. 2 figs.

Roach, P.R.; Gray, K.E.

1988-09-13T23:59:59.000Z

157

Performance bound for quantum absorption refrigerators  

E-Print Network (OSTI)

An implementation of quantum absorption chillers with three qubits has been recently proposed, that is ideally able to reach the Carnot performance regime. Here we study the working efficiency of such self-contained refrigerators, adopting a consistent treatment of dissipation effects. We demonstrate that the coefficient of performance at maximum cooling power is upper bounded by 3/4 of the Carnot performance. The result is independent of the details of the system and the equilibrium temperatures of the external baths. We provide design prescriptions that saturate the bound in the limit of a large difference between the operating temperatures. Our study suggests that delocalized dissipation, which must be taken into account for a proper modelling of the machine-baths interaction, is a fundamental source of irreversibility which prevents the refrigerator from approaching the Carnot performance arbitrarily closely in practice. The potential role of quantum correlations in the operation of these machines is also investigated.

Luis A. Correa; Jos P. Palao; Gerardo Adesso; Daniel Alonso

2012-12-18T23:59:59.000Z

158

ADVANCED CUTTINGS TRANSPORT STUDY  

SciTech Connect

ACTS flow loop is now operational under elevated pressure and temperature. Currently, experiments with synthetic based drilling fluids under pressure and temperature are being conducted. Based on the analysis of Fann 70 data, empirical correlations defining the shear stress as a function of temperature, pressure and the shear rate have been developed for Petrobras synthetic drilling fluids. PVT equipment has been modified for testing Synthetic oil base drilling fluids. PVT tests with Petrobras Synthetic base mud have been conducted and results are being analyzed Foam flow experiments have been conducted and the analysis of the data has been carried out to characterize the rheology of the foam. Comparison of pressure loss prediction from the available foam hydraulic models and the test results has been made. Cuttings transport experiments in horizontal annulus section have been conducted using air, water and cuttings. Currently, cuttings transport tests in inclined test section are being conducted. Foam PVT analysis tests have been conducted. Foam stability experiments have also been conducted. Effects of salt and oil concentration on the foam stability have been investigated. Design of ACTS flow loop modification for foam and aerated mud flow has been completed. A flow loop operation procedure for conducting foam flow experiments under EPET conditions has been prepared Design of the lab-scale flow loop for dynamic foam characterization and cuttings monitoring instrumentation tests has been completed. The construction of the test loop is underway. As part of the technology transport efforts, Advisory Board Meeting with ACTS-JIP industry members has been organized on May 13, 2000.

Ergun Kuru; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Gerald Kane; Mark Pickell; Len Volk; Mike Volk; Barkim Demirdal; Affonso Lourenco; Evren Ozbayoglu; Paco Vieira; Neelima Godugu

2000-07-30T23:59:59.000Z

159

Development of Refrigerant Change Indicator and Dirty Air Filter Sensor  

Science Conference Proceedings (OSTI)

The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks and dirty air filters. Equipment users are usually not aware of a problem until most of the refrigerant has escaped or the air filter is clogged with dirt. While a dirty air filter can be detected with a technology based on the air pressure differential across the filter, such as a ''whistling'' indicator, it is not easy to incorporate this technology into existing HVAC diagnostic equipment. Oak Ridge National Laboratory is developing a low-cost, nonintrusive refrigerant charge indicator and dirty air filter detection sensor. The sensors, based on temperature measurements, will be inexpensive and easy to incorporate into existing heat pumps and air conditioners. The refrigerant charge indicator is based on the fact that when refrigerant starts to leak, the evaporator coil temperature starts to drop and the level of liquid subcooling drops. When the coil temperature or liquid subcooling drops below a preset reading, a signal, such as a yellow warning light, can be activated to warn the equipment user that the system is undercharged. A further drop of coil temperature or liquid subcooling below another preset reading would trigger a second warning signal, such as a red warning light, to warn the equipment user that the unit now detects a leak and immediate action should be taken. The warning light cannot be turned off until it is re-set by a refrigeration repairman. To detect clogged air filters, two additional temperature sensors can be applied, one each across the evaporator. When the air filter is accumulating buildup, the temperature differential across the evaporator will increase because of the reduced airflow. When the temperature differential reaches a pre-set reading, a signal will be sent to the equipment user that the air filter needs to be changed. A traditional refrigerant charge indicator requires intrusion into the system to measure the refrigerant high-side and low-side pressures. Once the pressures are known, based on the equipment's refrigerant charging chart? or in most cases, based on the technician's experience? the refrigerant charging status is determined. However, there is a catch: by the time a refrigeration technician is called, most of the refrigerant has already escaped into the atmosphere. The new technology provides a real-time warning so that when, say, 20% of the refrigerant has leaked, the equipment users will be warned, even though the equipment is still functioning properly at rated capacity. Temperature sensors are becoming very accurate and very low in cost, compared with pressure sensors. Using temperature sensors to detect refrigerant charge status is inherently nonintrusive, inexpensive, and accurate. With the addition of two temperature sensors for detecting dirty air filters, the capability of the diagnostic equipment is further enhanced with very little added cost. This report provides laboratory test data on the change of indoor coil refrigerant temperature and subcooling as a function of refrigerant charge for a 2-ton split heat pump system. The data can be used in designing the indicators for refrigerant loss and dirty air filter sensors.

Mei, V.

2003-06-24T23:59:59.000Z

160

Energy and global warming impacts of next generation refrigeration and air conditioning technologies  

SciTech Connect

Significant developments have occurred in hydrofluorocarbon (HFC) and the application of ammonia and hydrocarbons as refrigerant working fluids since the original TEWI (Total Equivalent Warming Impact) report in 1991. System operating and performance data on alternative refrigerants and refrigeration technologies justify and updated evaluation of these new alternative refrigerants and competing technologies in well-characterized applications. Analytical and experimental results are used to show quantitative comparisons between HFCS, HFC blends, hydrocarbons, and ammonia, used as refrigerants. An objective evaluation is presented for commercial and near commercial non-CFC refrigerants/blowing agents and alternative refrigeration technologies. This information is needed for objective and quantitative decisions on policies addressing greenhouse gas emissions from refrigeration and air conditioning equipment. The evaluation assesses the energy use and global warming impacts of refrigeration and air conditioning technologies that could be commercialized during the phase out of HCFCS. Quantitative comparison TEWI for two application areas are presented. Opportunities for significant reductions in TEWI are seen with currently known refrigerants through improved maintenance and servicing practices and improved product designs.

Sand, J.R.; Fischer, S.K.; Baxter, V.D.

1996-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Counter-Top Thermoacoustic Refrigerator- An Experimental Investigation  

SciTech Connect

Thermoacoustic phenomenon is a new alternative refrigeration technology. Though design and fabrication is complex for getting the desired effect, it is environmentally friendly and successful system showed that it is relatively easy to run compared to the traditional vapor compression refrigeration system. Currently, theories supporting the thermoacoustic refrigeration systems are yet to be comprehensive to make them commercially viable. Theoretical, experimental, and numerical studies are being done to address the thermodynamics-acoustics interactions. In this study, experimental investigations were completed to test the feasibility of the practical use of a thermoacoustic refrigerator in its counter-top form for future specific application. The system was designed and fabricated based on linear acoustic theory. Acoustic power was given by a loud speaker and thermoacoustic effects were measured in terms of the cooling effects produced at resonanance. Investigations showed that discrepancies between designed and working resonance frequency exist. Thermoacoutic cooling improved at a certain frequency, achieved when the working frequency was varied away from the design frequency. A cooling effect of 4.8 K below the ambient temperature of 23.3 deg. C was obtained from the counter-top thermoacoustic system. This system uses no refrigerants and no compressor to generate the cooling effect, a potential to be further investigated for a practical system.

Anwar, Mahmood; Ghazali, Normah Mohd [Department of Thermo-Fluids, Faculty of Mechanical Engineering, Universiti Teknologi Malaysia Skudai 81310, Johor (Malaysia)

2010-06-28T23:59:59.000Z

162

Compatibility of refrigerants and lubricants with elastomers. Quarterly report, 1 April 1992--30 June 1992  

Science Conference Proceedings (OSTI)

Information contained in this reporters designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. Swell measurements have been made on approximately 50% of the proposed elastomers (94 total)in both the lubricant (7 total) and refrigerant (10 total) materials. Swell behavior in the these fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1992-07-01T23:59:59.000Z

163

Cryogenic refrigeration apparatus  

DOE Patents (OSTI)

A technique for producing a cold environment in a refrigerant system in which input fluid from a compressor at a first temperature is introduced into an input channel of the system and is pre-cooled to a second temperature for supply to one of at least two stages of the system, and to a third temperature for supply to another stage thereof. The temperatures at such stages are reduced to fourth and fifth temperatures below the second and third temperatures, respectively. Fluid at the fourth temperature from the one stage is returned through the input channel to the compressor and fluid at the fifth temperature from the other stage is returned to the compressor through an output channel so that pre-cooling of the input fluid to the one stage occurs by regenerative cooling and counterflow cooling and pre-cooling of the input fluid to the other stage occurs primarily by counterflow cooling.

Crunkleton, James A. (Cambridge, MA)

1992-01-01T23:59:59.000Z

164

Cryogenic refrigeration apparatus  

DOE Patents (OSTI)

A technique for producing a cold environment in a refrigerant system in which input fluid from a compressor at a first temperature is introduced into an input channel of the system and is pre-cooled to a second temperature for supply to one of at least two stages of the system, and to a third temperature for supply to another stage thereof. The temperatures at such stages are reduced to fourth and fifth temperatures below the second and third temperatures, respectively. Fluid at the fourth temperature from the one stage is returned through the input channel to the compressor and fluid at the fifth temperature from the other stage is returned to the compressor through an output channel so that pre-cooling of the input fluid to the one stage occurs by regenerative cooling and counterflow cooling and pre-cooling of the input fluid to the other stage occurs primarily by counterflow cooling. 6 figs.

Crunkleton, J.A.

1992-03-31T23:59:59.000Z

165

The Quantum Absorption Refrigerator  

E-Print Network (OSTI)

A quantum absorption refrigerator driven by noise is studied with the purpose of determining the limitations of cooling to absolute zero. The model consists of a working medium coupled simultaneously to hot, cold and noise baths. Explicit expressions for the cooling power are obtained for Gaussian and Poisson white noise. The quantum model is consistent with the first and second laws of thermodynamics. The third law is quantified, the cooling power J_c vanishes as J_c proportional to T_c^{alpha}, when T_c approach 0, where alpha =d+1 for dissipation by emission and absorption of quanta described by a linear coupling to a thermal bosonic field, where d is the dimension of the bath.

Amikam Levy; Ronnie Kosloff

2011-09-04T23:59:59.000Z

166

Magnetic refrigeration apparatus and method  

SciTech Connect

The disclosure relates to refrigeration through magnetizing and demagnitizing a body by rotating it within a magnetic field. Internal and external heat exchange fluids and in one embodiment, a regenerator, are used.

Barclay, John A. (Los Alamos, NM); Overton, Jr., William C. (Los Alamos, NM); Stewart, Walter F. (Los Alamos, NM)

1984-01-01T23:59:59.000Z

167

Impact of the Variable Refrigerant Volume Air Conditioning System on Building Energy Efficiency  

E-Print Network (OSTI)

The application of the variable refrigerant volume multi-zone air conditioning systems has met with mixed results since the publication of the Design Standard for Energy Efficiency of Public Buildings. This paper analyzes the characteristics of the variable refrigerant volume multi-zone air conditioning system, and discusses the advantages of its application.

Zhu, H.

2006-01-01T23:59:59.000Z

168

Chapter 4: Refrigeration Process Control: Simulation Model 64 44.. RREEFFRRIIGGEERRAATTIIOONN PPRROOCCEESSSS  

E-Print Network (OSTI)

Chapter 4: Refrigeration Process Control: Simulation Model 64 44.. RREEFFRRIIGGEERRAATTIIOONN of the simulation model for the two-stage refrigeration system is presented. The model is based on the mathematical equations and transfer functions. Typical application areas are control system design, chemical process

Skogestad, Sigurd

169

Portable cutting apparatus  

DOE Patents (OSTI)

A remotely operable, portable cutting apparatus detachably secured to the workpiece by laterally spaced clamp assemblies engagable with the workpiece on opposite sides of the intended line of cut. A reciprocal cutter head is mounted between the clamp assemblies and is provided with a traveling abrasive cutting wire adapted to sever the workpiece normal to the longitudinal axis thereof. Dust and debris are withdrawn from the cutting area by a vacuum force through a nozzle mounted on the cutting head.

Gilmore, R.F.

1984-07-17T23:59:59.000Z

170

Portable cutting apparatus  

DOE Patents (OSTI)

A remotely operable, portable cutting apparatus detachably secured to the workpiece by laterally spaced clamp assemblies engageable with the workpiece on opposite sides of the intended line of cut. A reciprocal cutter head is mounted between the clamp assemblies and is provided with a traveling abrasive cutting wire adapted to sever the workpiece normal to the longitudinal axis thereof. Dust and debris are withdrawn from the cutting area by a vacuum force through a nozzle mounted on the cutting head.

Gilmore, Richard F. (Kennewick, WA)

1986-01-01T23:59:59.000Z

171

Dilution Refrigeration of Multi-Ton Cold Masses  

E-Print Network (OSTI)

Dilution refrigeration is the only means to provide continuous cooling at temperatures below 250 mK. Future experiments featuring multi-ton cold masses require a new generation of dilution refrigeration systems, capable of providing a heat sink below 10 mK at cooling powers which exceed the performance of present systems considerably. This thesis presents some advances towards dilution refrigeration of multi-ton masses in this temperature range. A new method using numerical simulation to predict the cooling power of a dilution refrigerator of a given design has been developed in the framework of this thesis project. This method does not only allow to take into account the differences between an actual and an ideal continuous heat exchanger, but also to quantify the impact of an additional heat load on an intermediate section of the dilute stream. In addition, transient behavior can be simulated. The numerical model has been experimentally verified with a dilution refrigeration system which has been designed, ...

Wikus, P; CERN. Geneva

2007-01-01T23:59:59.000Z

172

International linear collider reference design report  

E-Print Network (OSTI)

refrigeration below 4.2 Kelvin. All of these e?ciencies are in accordance with recent industrial conceptual design

Aarons, G.

2008-01-01T23:59:59.000Z

173

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

Page 1. Thermal Analysis of Refrigeration Systems Used for Vaccine Storage ... Suitability of commercial refrigerators for vaccine storage not ...

2012-08-03T23:59:59.000Z

174

Adjustable cutting tool holder  

DOE Patents (OSTI)

This patent application describes a device for varying the geometry of a cutting tool for use in machining operations.

Steinhour, William Lee III; West, Drew; Honeycutt, Steve; Frank, Steven; Krishnamurthy, Kallutla

2000-09-21T23:59:59.000Z

175

cutting stock problem  

Science Conference Proceedings (OSTI)

NIST. cutting stock problem. (classic problem). Definition: Find the best arrangement of shapes on rectangles to minimize ...

2013-08-23T23:59:59.000Z

176

International Refrigeration: Order (2012-CE-1510)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered International Refrigeration Products to pay an $8,000 civil penalty after finding International Refrigeration had failed to certify that certain room air conditioners comply with the applicable energy conservation standard.

177

Cospolich Refrigerator: Order (2013-CE-5314)  

Energy.gov (U.S. Department of Energy (DOE))

DOE ordered Cospolich Refrigerator Co, Inc. to pay a $8,000 civil penalty after finding Cospolich Refrigerator had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards.

178

Thermoelectric refrigerator having improved temperature stabilization means  

DOE Patents (OSTI)

A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature, but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized.

Falco, Charles M. (Woodridge, IL)

1982-01-01T23:59:59.000Z

179

DOE Proposes Higher Efficiency Standards for Refrigerators  

Energy.gov (U.S. Department of Energy (DOE))

New Proposed Standards for Residential Refrigerators and Freezers to Lower Energy Use by as much as Twenty-Five Percent

180

Magnetocaloric Effect and Enhanced Refrigeration effectiveness in ...  

Science Conference Proceedings (OSTI)

Presentation Title, Magnetocaloric Effect and Enhanced Refrigeration effectiveness in ... Industrial Needs and Applications for Soft Magnetic Materials Industrial...

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Optimization of the Refrigerant Capacity in Multiphase ...  

Science Conference Proceedings (OSTI)

Symposium, Magnetic Materials for Energy Applications. Presentation Title, Optimization of the Refrigerant Capacity in Multiphase Magnetocaloric Materials.

182

Safety audit of refrigerated liquefied gas facilities  

SciTech Connect

An Exxon Research and Engineering Co. comprehensive review of engineering practices and application of safety requirements at Exxon's world-wide refrigerated liquefied hydrocarbon gas storage and handling installations, which included a field audit of about 90 tanks at 30 locations, showed that catastrophic tank failure was not a credible event with properly operated and maintained tanks designed, constructed, and tested in accordance with API Standard 620, Design and Construction of Large Welded Low-Pressure Storage Tanks, although supplemental requirements were suggested to further enhance safety. The review also showed that any meaningful safety audit should be comprehensive and must include all facilities with careful attention to detail. The review embraces products of -1 to -167C and included LNG, ethylene, LPG, and LPG olefins. Recent and proposed LNG safety legislation; some field audit results; and recommendations as to design, construction, and operation of LNG and LPG storage facilities, marine terminals, and tankers, are also discussed.

Feely, F.J.; Sommer, E.C.; Marshall, B.T.; Palmer, A.J.

1980-01-01T23:59:59.000Z

183

Wheel-type magnetic refrigerator  

DOE Patents (OSTI)

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load.

Barclay, John A. (Los Alamos, NM)

1983-01-01T23:59:59.000Z

184

Wheel-type magnetic refrigerator  

DOE Patents (OSTI)

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load.

Barclay, J.A.

1982-01-20T23:59:59.000Z

185

Wheel-type magnetic refrigerator  

DOE Patents (OSTI)

The disclosure is directed to a wheel-type magnetic refrigerator capable of cooling over a large temperature range. Ferromagnetic or paramagnetic porous materials are layered circumferentially according to their Curie temperature. The innermost layer has the lowest Curie temperature and the outermost layer has the highest Curie temperature. The wheel is rotated through a magnetic field perpendicular to the axis of the wheel and parallel to its direction of rotation. A fluid is pumped through portions of the layers using inner and outer manifolds to achieve refrigeration of a thermal load. 7 figs.

Barclay, J.A.

1983-10-11T23:59:59.000Z

186

New Modelling Strategies For Metal Cutting  

Science Conference Proceedings (OSTI)

This paper draws from the 'plasticity and friction only' view of metal cutting to the presentation of new modelling strategies based on the interaction between finite elements and modern ductile fracture mechanics. The overall presentation is supported by specially designed orthogonal metal cutting experiments that were performed on Lead test specimens under laboratory-controlled conditions. Comparisons between theoretical predictions and experimental results comprise a wide range of topics such as material flow, cutting forces and specific cutting pressure. The paper demonstrates that while material flow and chip formation can be successfully modelled by traditional 'plasticity and friction only' analyses, the contribution of the fracture work involved in the formation of new surfaces is essential for obtaining good estimates of cutting forces and of the specific cutting pressure.

Rosa, Pedro A. R.; Martins, Paulo A. F. [Instituto Superior Tecnico, Departamento de Engenharia Mecanica, Av. Rovisco Pais, 1049-001 Lisbon (Portugal); Atkins, Anthony G. [Department of Engineering, University of Reading, Box 225, Reading RG6 6AY (United Kingdom)

2007-05-17T23:59:59.000Z

187

Ternary Dy-Er-Al magnetic refrigerants  

DOE Patents (OSTI)

A ternary magnetic refrigerant material comprising (Dy{sub 1{minus}x}Er{sub x})Al{sub 2} for a magnetic refrigerator using the Joule-Brayton thermodynamic cycle spanning a temperature range from about 60K to about 10K, which can be adjusted by changing the Dy to Er ratio of the refrigerant. 29 figs.

Gschneidner, K.A. Jr.; Takeya, Hiroyuki

1995-07-25T23:59:59.000Z

188

Method and apparatus for desuperheating refrigerant  

DOE Patents (OSTI)

The present invention is an apparatus and method for de-superheating a primary refrigerant leaving a compressor wherein a secondary refrigerant is used between the primary refrigerant to be de-superheated. Reject heat is advantageously used for heat reclaim.

Zess, James A. (Kelso, WA); Drost, M. Kevin (Richland, WA); Call, Charles J. (Richland, WA)

1997-01-01T23:59:59.000Z

189

Ternary Dy-Er-Al magnetic refrigerants  

DOE Patents (OSTI)

A ternary magnetic refrigerant material comprising (Dy.sub.1-x Er.sub.x)Al.sub.2 for a magnetic refrigerator using the Joule-Brayton thermodynamic cycle spanning a temperature range from about 60K to about 10K, which can be adjusted by changing the Dy to Er ratio of the refrigerant.

Gschneidner, Jr., Karl A. (Ames, IA); Takeya, Hiroyuki (Ibaraki, JP)

1995-07-25T23:59:59.000Z

190

Investigation of Chlorine-Free Refrigerants for Low-Temperature Supermarket Refrigeration  

Science Conference Proceedings (OSTI)

With the phaseout of chlorofluorocarbon (CFC) refrigerants, supermarkets are seeking a replacement for R-502, the refrigerant of choice for low-temperature (frozen food) refrigeration. EPRI has conducted field testing to characterize the performance of the new hydrofluorocarbon (HFC) nonchlorinated refrigerants replacements for R-502. Results showed that energy and demand savings can be obtained using these alternative refrigerants with zero ozone-depleting potential.

1996-08-10T23:59:59.000Z

191

Compatibility of refrigerants and lubricants with elastomers. Quarterly report, 1 July 1992--30 September 1992  

SciTech Connect

Information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on the availability of additional quantities of R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 hours and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1992-10-01T23:59:59.000Z

192

Compatibility of refrigerants and lubricants with elastomers. Quarterly report, 1 October 1992--30 December 1992  

Science Conference Proceedings (OSTI)

The information contained in this report is designed to assist the air-conditioning and refrigeration industry in the selection of suitable elastomeric gasket and seal materials that will prove useful in various refrigerant and refrigeration lubricant environments. 97% of the swell measurements have been made to date. The other 3% of the measurements are contingent on availability of additional R-32. Swell behavior in the fluids have been determined using weight and in situ diameter measurements for the refrigerants and weight, diameter and thickness measurements for the lubricants. Weight and diameter measurements are repeated after 2 and 24 hours for samples removed from the refrigerant test fluids and 24 hours after removal from the lubricants.

Hamed, G.R.; Seiple, R.H.

1993-01-01T23:59:59.000Z

193

Opportunities for Energy Efficiency and Automated Demand Response in Industrial Refrigerated Warehouses in California  

E-Print Network (OSTI)

Design Essentials for Refrigerated Storage Facilities,the facility HVAC loads can be shed in non- essential areasfacility HVAC load by raising temperature set points in non-essential

Lekov, Alex

2009-01-01T23:59:59.000Z

194

Device for cutting protrusions  

DOE Patents (OSTI)

An apparatus for clipping a protrusion of material is provided. The protrusion may, for example, be a bolt head, a nut, a rivet, a weld bead, or a temporary assembly alignment tab protruding from a substrate surface of assembled components. The apparatus typically includes a cleaver having a cleaving edge and a cutting blade having a cutting edge. Generally, a mounting structure configured to confine the cleaver and the cutting blade and permit a range of relative movement between the cleaving edge and the cutting edge is provided. Also typically included is a power device coupled to the cutting blade. The power device is configured to move the cutting edge toward the cleaving edge. In some embodiments the power device is activated by a momentary switch. A retraction device is also generally provided, where the retraction device is configured to move the cutting edge away from the cleaving edge.

Bzorgi, Fariborz M. (Knoxville, TN)

2011-07-05T23:59:59.000Z

195

Low-temperature magnetic refrigerator  

SciTech Connect

The disclosure is directed to a low temperature 4 to 20 K. refrigeration apparatus and method utilizing a ring of magnetic material moving through a magnetic field. Heat exchange is accomplished in and out of the magnetic field to appropriately utilize the device to execute Carnot and Stirling cycles.

Barclay, John A. (Los Alamos, NM)

1985-01-01T23:59:59.000Z

196

Direct condensation refrigerant recovery and restoration system  

Science Conference Proceedings (OSTI)

This patent describes a refrigerant recovery and purification system for removing gaseous refrigerant from a disabled refrigeration unit, cleaning the refrigerant of contaminants, and converting the gaseous refrigerant to a liquid state for storage. It comprises a low pressure inlet section; a high pressure storage section; the low pressure inlet section comprising: an oil and refrigerant gas separator, including a separated oil removal means, first conduit means for connecting an inlet of the separator to the disabled refrigerant unit, a slack-sided accumulator, second conduit means connecting the separator to the slack-sided accumulator, a reclaim condenser, third conduit means connecting the separator and the reclaim condenser in series, an evaporator coil in the reclaim condenser connectable to a conventional operating refrigeration system for receiving a liquid refrigerant under pressure for expansion therein, the evaporator coil forming a condensing surface for condensing the refrigerant gas at near atmospheric pressure in the condenser, a liquid receiver, a reclaimed refrigerant storage tank, fourth conduit means further connecting the liquid receiver in series with the reclaim condenser, downstream thereof, means between the reclaim condenser and the liquid receiver.

Grant, D.C.H.

1992-03-10T23:59:59.000Z

197

Speed Control in Industrial Refrigeration: Theory, Application & Case Studies  

E-Print Network (OSTI)

It is often standard practice in the field of industrial refrigeration to design and operate systems with little regard toward part-load performance. This approach is understandable, whether viewed from the standpoint of the design engineer, plant manager or chief operator. As long a space temperature and production rates are maintained during peak periods, the refrigeration system is viewed as operating "correctly". The truth is, most refrigeration systems spend some, if not most operating hours at reduced capacity. Screw compressors back off slide valves, evaporator coils utilize back-pressure regulators (BPRs) or liquid solenoids, and condensers cycle fans. Unfortunately, these control methods do not provide the maximum attainable reduction in brake horsepower (BHP) as refrigeration capacity is reduced. This paper will discuss the application of variable speed drive (VSD, also called "variable frequency drive", "adjustable speed drive", "inverter", or simply "freq. drive") technology to capacity control of screw compressors, evaporator fans, and condenser fans. As shown through theory and case study, speed control of these components provides maximum flexibility, control and energy efficiency.

Wilcox, M. H.

1995-04-01T23:59:59.000Z

198

ADVANCED CUTTINGS TRANSPORT STUDY  

DOE Green Energy (OSTI)

Final design of the mast was completed (Task 5). The mast is consisting of two welded plate girders, set next to each other, and spaced 14-inches apart. Fabrication of the boom will be completed in two parts solely for ease of transportation. The end pivot connection will be made through a single 2-inch diameter x 4 feet-8 inch long 316 SS bar. During installation, hard piping make-ups using Chiksan joints will connect the annular section and 4-inch return line to allow full movement of the mast from horizontal to vertical. Additionally, flexible hoses and piping will be installed to isolate both towers from piping loads and allow recycling operations respectively. Calibration of the prototype Foam Generator Cell has been completed and experiments are now being conducted. We were able to generate up to 95% quality foam. Work is currently underway to attach the Thermo-Haake RS300 viscometer and install a view port with a microscope to measure foam bubble size and bubble size distribution. Foam rheology tests (Task 13) were carried out to evaluate the rheological properties of the proposed foam formulation. After successful completion of the first foam test, two sets of rheological tests were conducted at different foam flow rates while keeping other parameters constant (100 psig, 70F, 80% quality). The results from these tests are generally in agreement with the previous foam tests done previously during Task 9. However, an unanticipated observation during these tests was that in both cases, the frictional pressure drop in 2 inch pipe was lower than that in the 3 inch and 4 inch pipes. We also conducted the first foam cuttings transport test during this quarter. Experiments on aerated fluids without cuttings have been completed in ACTF (Task 10). Gas and liquid were injected at different flow rates. Two different sets of experiments were carried out, where the only difference was the temperature. Another set of tests was performed, which covered a wide range of pressure and temperature. Several parameters were measured during these tests including differential pressure and mixture density in the annulus. Flow patterns during the aerated fluids test have been observed through the view port in the annulus and recorded by a video camera. Most of the flow patterns were slug flow. Further increase in gas flow rate changed the wavy flow pattern to slug flow. At this stage, all of the planned cuttings transport tests have been completed. The results clearly show that temperature significantly affects the cuttings transport efficiency of aerated muds, in addition to the liquid flow rate and gas liquid ratio (GLR). Since the printed circuit board is functioning (Task 11) with acceptable noise level we were able to conduct several tests. We used the newly designed pipe test section to conduct tests. We tested to verify that we can distinguish between different depths of sand in a static bed of sand in the pipe section. The results indicated that we can distinguish between different sand levels. We tested with water, air and a mix of the two mediums. Major modifications (installation of magnetic flow meter, pipe fittings and pipelines) to the dynamic bubble characterization facility (DTF, Task 12) were completed. An Excel program that allows obtaining the desired foam quality in DTF was developed. The program predicts the foam quality by recording the time it takes to pressurize the loop with nitrogen.

Stefan Miska; Nicholas Takach; Kaveh Ashenayi

2004-01-31T23:59:59.000Z

199

Mechanical refrigerator for deep well sonde electronics, Phase II. Final report  

DOE Green Energy (OSTI)

The system is based on a vapor cycle refrigeration system with the usual compressor, evaporator and condenser. It is designed to operate between a condensing temperature of 275/sup 0/C and an evaporating temperature of 125/sup 0/C. Water vapor is the refrigerant. The compressor is an electric motor driven three-stage positive displacement machine. The design output of the refrigerator is 50 watts cooling. The work described covers the development of the compressor with associated component development tests. The compressor was tested in a loop simulating downhole conditions. Short duration runs were accomplished where study state conditions of refrigerant and lubricant flows were established. However, because of various component failures, sustained operations, greater than 6 hours at a time, could not be made. (The design goal was 100 hours.)

Fukuzawa, J.

1979-04-09T23:59:59.000Z

200

B. Air Conditioning and Refrigeration Institute (ARI). C. American Society of Mechanical Engineers (ASME). D. Cryogenic Society of America (CSA).  

E-Print Network (OSTI)

a. Design and specify refrigeration systems and equipment in accordance with "Energy Conservation Standards " stipulated in Section 15010- Basic Mechanical Requirements. b. Every effort should be made to specify equipment which does not require any CFC refrigerants, including R-11, R-12, R113, or

Cooling Tower Sump Filtration System

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Refrigeration requirements for fusion reactors based upon the theta-pinch concept  

DOE Green Energy (OSTI)

Two refrigeration systems applicable to the theta-pinch fusion concept are described. The first is a 1100 W, 4.5 K refrigerator which will be used for testing superconducting NbTi Magnetic Energy Transfer and Storage (METS) coil systems. This unit is currently being installed and is to be operational by April 1977. The second unit is applicable to the Syllac Fusion Test Reactor (SFTR) and has been conceptually designed. This liquefier-refrigerator is about 22 times larger than those in existence at present and will require 12-MW input electrical power. It will provide 3045 kg/h of liquid helium at 4.5 K.

Williamson, K.D. Jr.; King, C.R.

1976-01-01T23:59:59.000Z

202

A note on branch-and-cut-and-price  

Science Conference Proceedings (OSTI)

In this paper, we propose a methodology for branch-and-cut-and-price when cuts and columns are generated simultaneously. The methodology is illustrated with two application cases: the Split Delivery Vehicle Routing Problem (SDVRP) and the Bus Rapid Transit ... Keywords: Branch-and-cut-and-price, Bus Rapid Transit Route Design Problem, Column generation, Split Delivery Vehicle Routing Problem

Dominique Feillet; Michel Gendreau; AndrS L. Medaglia; Jose L. Walteros

2010-09-01T23:59:59.000Z

203

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) Duracold Refrigeration Manufacturing: Order (2013-CE-5342) April 25, 2013 DOE ordered Duracold Refrigeration Manufacturing Company, LLC to pay a $8,000 civil penalty after finding Duracold Refrigeration Manufacturing had failed to certify that certain models of walk-in cooler and freezer components comply with the applicable energy conservation standards. The Order adopted a Compromise Agreement, which reflected settlement terms between DOE and Duracold Refrigeration Manufacturing. Duracold Refrigeration Manufacturing: Order (2013-CE-5342) More Documents & Publications Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) North Star Refrigerator: Order (2013-CE-5355) Schott Gemtron: Order (2013-CE-5358

204

Optimal Performance of Quantum Refrigerators  

E-Print Network (OSTI)

A reciprocating quantum refrigerator is studied with the purpose of determining the limitations of cooling to absolute zero. We find that if the energy spectrum of the working medium possesses an uncontrollable gap, then there is a minimum achievable temperature above zero. Such a gap, combined with a negligible amount of noise, prevents adiabatic following during the demagnetization stage which is the necessary condition for reaching $T_c \\to 0$. The refrigerator is based on an Otto cycle where the working medium is an interacting spin system with an energy gap. For this system the external control Hamiltonian does not commute with the internal interaction. As a result during the demagnetization and magnetization segments of the operating cycle the system cannot follow adiabatically the temporal change in the energy levels. We connect the nonadiabatic dynamics to quantum friction. An adiabatic measure is defined characterizing the rate of change of the Hamiltonian. Closed form solutions are found for a const...

Feldmann, Tova

2009-01-01T23:59:59.000Z

205

Quantum-enhanced absorption refrigerators  

E-Print Network (OSTI)

Thermodynamics is a branch of science blessed by an unparalleled combination of generality of scope and formal simplicity. Based on few natural assumptions together with the four laws, it sets the boundaries between possible and impossible in macroscopic aggregates of matter. This triggered groundbreaking achievements in physics, chemistry and engineering over the last two centuries. Close analogues of those fundamental laws are now being established at the level of individual quantum systems, thus placing limits on the operation of quantum-mechanical devices. Here we study quantum absorption refrigerators, which are driven by heat rather than external work. We establish thermodynamic performance bounds for these machines and investigate their quantum origin. We also show how those bounds may be pushed beyond what is classically achievable, by suitably tailoring the environmental fluctuations via quantum reservoir engineering techniques. Such superefficient quantum-enhanced cooling realises a promising step towards the technological exploitation of autonomous quantum refrigerators.

Luis A. Correa; Jos P. Palao; Daniel Alonso; Gerardo Adesso

2013-08-19T23:59:59.000Z

206

Magnetic Refrigeration Technology for High Efficiency Air Conditioning  

SciTech Connect

Magnetic refrigeration was investigated as an efficient, environmentally friendly, flexible alternative to conventional residential vapor compression central air conditioning systems. Finite element analysis (FEA) models of advanced geometry active magnetic regenerator (AMR) beds were developed to minimize bed size and thus magnet mass by optimizing geometry for fluid flow and heat transfer and other losses. Conventional and magnetocaloric material (MCM) regenerator fabrication and assembly techniques were developed and advanced geometry passive regenerators were built and tested. A subscale engineering prototype (SEP) magnetic air conditioner was designed, constructed and tested. A model of the AMR cycle, combined with knowledge from passive regenerator experiments and FEA results, was used to design the regenerator beds. A 1.5 Tesla permanent magnet assembly was designed using FEA and the bed structure and plenum design was extensively optimized using FEA. The SEP is a flexible magnetic refrigeration platform, with individually instrumented beds and high flow rate and high frequency capability, although the current advanced regenerator geometry beds do not meet performance expectations, probably due to manufacturing and assembly tolerances. A model of the AMR cycle was used to optimize the design of a 3 ton capacity magnetic air conditioner, and the system design was iterated to minimize external parasitic losses such as heat exchanger pressure drop and fan power. The manufacturing cost for the entire air conditioning system was estimated, and while the estimated SEER efficiency is high, the magnetic air conditioning system is not cost competitive as currently configured. The 3 ton study results indicate that there are other applications where magnetic refrigeration is anticipated to have cost advantages over conventional systems, especially applications where magnetic refrigeration, through the use of its aqueous heat transfer fluid, could eliminate intermediate heat exchangers or oil distribution issues found in traditional vapor compression systems.

Boeder, A; Zimm, C

2006-09-30T23:59:59.000Z

207

Suction muffler for refrigeration compressor  

SciTech Connect

A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell.

Nelson, Richard T. (Worthington, OH); Middleton, Marc G. (West Jefferson, OH)

1983-01-01T23:59:59.000Z

208

Suction muffler for refrigeration compressor  

DOE Patents (OSTI)

A hermetic refrigeration compressor includes a suction muffler formed from two pieces of plastic material mounted on the cylinder housing. One piece is cylindrical in shape with an end wall having an aperture for receiving a suction tube connected to the cylinder head. The other piece fits over and covers the other end of the cylindrical piece, and includes a flaring entrance horn which extends toward the return line on the sidewall of the compressor shell. 5 figs.

Nelson, R.T.; Middleton, M.G.

1983-01-25T23:59:59.000Z

209

Procurement and commissioning of the CHL refrigerator at CEBAF  

SciTech Connect

The CEBAF Central Helium Liquefier (CHL) provides 2K refrigeration to the 338 superconducting niobium cavities in two 400 MeV linacs and one 45 MeV injector. The CHL consists of three first stage and three second stage compressors, a 4.5K cold box, a 2K cold box, liquid and gaseous helium storage, liquid nitrogen storage, and transfer lines. Figure 1 presents a block diagram of the CHL refrigerator. The system was designed to provide 4.8 kW of primary refrigeration at 2K, 12 kW of shield refrigeration at 45K for the linac cryomodules, and 10 g/s of liquid flow for the end stations. In April 1994, stable 2K operation of the previously uncommissioned cold compressors was achieved. The cold compressors are a cold vacuum pump with an inlet temperature of circa 3.0K. These compressors operate on magnetic bearing,s and therefore eliminate the possibility of contamination due to any air leaks into the system. Operational data and commissioning experience as they relate to the warm gaseous helium compressors, turbines, instrumentation and control, and the cold compressors are presented.

Chronis, W.C.; Arenius, D.M.; Bevins, B.S.; Ganni, V.; Kashy, D.H.; Keesee, M.M.; Reid, T.R.; Wilson, J.D.

1996-08-01T23:59:59.000Z

210

Bipolar pulse field for magnetic refrigeration  

DOE Patents (OSTI)

A magnetic refrigeration apparatus includes first and second steady state magnets, each having a field of substantially equal strength and opposite polarity, first and second bodies made of magnetocaloric material disposed respectively in the influence of the fields of the first and second steady state magnets, and a pulsed magnet, concentric with the first and second steady state magnets, and having a field which cycles between the fields of the first and second steady state magnets, thereby cyclically magnetizing and demagnetizing and thus heating and cooling the first and second bodies. Heat exchange apparatus of suitable design can be used to expose a working fluid to the first and second bodies of magnetocaloric material. A controller is provided to synchronize the flow of working fluid with the changing states of magnetization of the first and second bodies. 2 figs.

Lubell, M.S.

1994-10-25T23:59:59.000Z

211

Transport Refrigeration Units: A Technical Assessment  

Science Conference Proceedings (OSTI)

This report evaluates the prospects for operating transport refrigeration systems on electricity while they are stationary at a distribution center or refrigerated warehouses. Because most transport refrigeration units (TRUs) in use today are powered by diesel engines, concentrations of diesel exhaust products including particulate matter occur near these distribution centers. Operating TRUs on electricity would eliminate diesel exhaust emissions concentrations at these facilities, but would increase cos...

2004-09-29T23:59:59.000Z

212

List of Refrigerators Incentives | Open Energy Information  

Open Energy Info (EERE)

Refrigerators Incentives Refrigerators Incentives Jump to: navigation, search The following contains the list of 657 Refrigerators Incentives. CSV (rows 1-500) CSV (rows 501-657) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Ohio - Commercial Custom Project Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial Institutional Local Government Nonprofit Schools State Government Tribal Government Boilers Central Air conditioners Chillers Custom/Others pending approval Furnaces Heat pumps Heat recovery Lighting Lighting Controls/Sensors Processing and Manufacturing Equipment Refrigerators Yes AEP Ohio - Commercial Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Fed. Government Industrial

213

Building Technologies Office: Refrigerated Beverage Vending Machines...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Use to Save Money. Learn More. News DOE Issues Notice of Proposed Rulemaking for Commercial Refrigeration Equipment Energy Conservation Standard August 29, 2013 DOE Issues...

214

Regenerator for Magnetic Refrigerants - Energy Innovation Portal  

Magnetic refrigeration is being investigated as an alternative to conventional gas compressor technology ... because of its potential to save energy and ...

215

An Alternative Refrigeration System For Automotive Applications.  

E-Print Network (OSTI)

??The air conditioning systems currently utilized in automobiles are the vapor compression systems. This type of system has many disadvantages: the refrigerant used is not (more)

McLaughlin, Shannon

2005-01-01T23:59:59.000Z

216

NIST Quantum Refrigerator Offers Extreme Cooling and ...  

Science Conference Proceedings (OSTI)

... NIST's prototype solid-state refrigerator uses quantum physics in the square chip mounted on the green circuit board to cool the much larger copper ...

2013-03-05T23:59:59.000Z

217

Cryogenics for superconductors: Refrigeration, delivery, and preservation of the cold  

SciTech Connect

Applications in superconductivity have become widespread, enabled by advancements in cryogenic engineering. In this paper, the history of cryogenic refrigeration, its delivery, its preservation and the important scientific and engineering advancements in these areas in the last 100 years will be reviewed, beginning with small laboratory dewars to very large scale systems. The key technological advancements in these areas that enabled the development of superconducting applications at temperatures from 4 to 77 K are identified. Included are advancements in the components used up to the present state-of-the-art in refrigeration systems design. Viewpoints as both an equipment supplier and the end-user with regard to the equipment design and operations will be presented. Some of the present and future challenges in these areas will be outlined. Most of the materials in this paper are a collection of the historical materials applicable to these areas of interest.

Venkatarao Ganni, James Fesmire

2012-06-01T23:59:59.000Z

218

INTERNAL CUTTING DEVICE  

DOE Patents (OSTI)

A device is described for removing material from the interior of a hollow workpiece so as to form a true spherical internal surface in a workpiece, or to cut radial slots of an adjustable constant depth in an already established spherical internal surface. This is accomplished by a spring loaded cutting tool adapted to move axially wherein the entire force urging the tool against the workpiece is derived from the spring. Further features of importance involve the provision of a seal between the workpiece and the cutting device and a suction device for carrying away particles of removed material.

Russell, W.H. Jr.

1959-06-30T23:59:59.000Z

219

Federal Energy Management Program: Covered Product Category: Refrigerated  

NLE Websites -- All DOE Office Websites (Extended Search)

Refrigerated Beverage Vending Machines to someone by E-mail Refrigerated Beverage Vending Machines to someone by E-mail Share Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Facebook Tweet about Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Twitter Bookmark Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Google Bookmark Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Delicious Rank Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on Digg Find More places to share Federal Energy Management Program: Covered Product Category: Refrigerated Beverage Vending Machines on AddThis.com...

220

DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements March 16, 2010 - 4:28pm...

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

... style refrigerator and a freezerless household refrigerator used ... possible that the nature of the cooling system and ... model simply do not cool the side ...

2012-08-02T23:59:59.000Z

222

Air-Conditioning, Heating, and Refrigeration Institute (AHRI...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI Air-Conditioning, Heating, and Refrigeration Institute (AHRI) Regulatory Burden RFI These comments...

223

U.S. Residential Miscellaneous Refrigeration Products: Results...  

NLE Websites -- All DOE Office Websites (Extended Search)

Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys Title U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon...

224

China Refrigerator Information Label: Specification Development and Potential Impact  

E-Print Network (OSTI)

ERKELEY N ATIONAL L ABORATORY China Refrigerator InformationDivision Jianhong Cheng China National Institute of7 Table 2 Coefficient Values for China Refrigerator 2003

Fridley, David

2008-01-01T23:59:59.000Z

225

Application of Cutting Fluids  

Science Conference Proceedings (OSTI)

...is transferred to the drill by a rotating gland and is forced directly into the cutting zone. The fluid flowing from the hole assists in chip removal. Oil-hole drills have become very popular in

226

Seven-effect absorption refrigeration  

DOE Patents (OSTI)

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit.

DeVault, Robert C. (Knoxville, TN); Biermann, Wendell J. (Fayetteville, NY)

1989-01-01T23:59:59.000Z

227

Seven-effect absorption refrigeration  

DOE Patents (OSTI)

A seven-effect absorption refrigeration cycle is disclosed utilizing three absorption circuits. In addition, a heat exchanger is used for heating the generator of the low absorption circuit with heat rejected from the condenser and absorber of the medium absorption circuit. A heat exchanger is also provided for heating the generator of the medium absorption circuit with heat rejected from the condenser and absorber of the high absorption circuit. If desired, another heat exchanger can also be provided for heating the evaporator of the high absorption circuit with rejected heat from either the condenser or absorber of the low absorption circuit. 1 fig.

DeVault, R.C.; Biermann, W.J.

1989-05-09T23:59:59.000Z

228

An overview of the planned Jefferson Lab 12-GeV helium refrigerator upgrade  

SciTech Connect

In February 2006, Jefferson Laboratory in Newport News, VA, received Critical Decision 1 (CD-1) approval to proceed with the engineering and design of the long anticipated upgrade to increase the beam energy of CEBAF, the Continuous Electron Beam Accelerator Facility, from 6 GeV to 12 GeV. This will require the installation of 10 new cryomodules, and additional 2.1-K refrigeration beyond the available 4600 W to handle the increased heat loads. Additionally, a new experimental hall, Hall D, is planned that will require the installation of a small, available refrigerator. This paper will present an overview of the integration of the new proposed refrigeration system into CEBAF, the installation of the available refrigerator for Hall D, and includes planned work scope, current schedule plans and project status.

Arenius, Dana; Creel, Jonathan; Dixon, Kelly; Ganni, Venkatarao; Knudsen, Peter; Sidi-Yekhlef, Ahmed; Wright, Mathew

2008-03-01T23:59:59.000Z

229

Optimal Performance of Quantum Refrigerators  

E-Print Network (OSTI)

A reciprocating quantum refrigerator is studied with the purpose of determining the limitations of cooling to absolute zero. We find that if the energy spectrum of the working medium possesses an uncontrollable gap, then there is a minimum achievable temperature above zero. Such a gap, combined with a negligible amount of noise, prevents adiabatic following during the demagnetization stage which is the necessary condition for reaching $T_c \\to 0$. The refrigerator is based on an Otto cycle where the working medium is an interacting spin system with an energy gap. For this system the external control Hamiltonian does not commute with the internal interaction. As a result during the demagnetization and magnetization segments of the operating cycle the system cannot follow adiabatically the temporal change in the energy levels. We connect the nonadiabatic dynamics to quantum friction. An adiabatic measure is defined characterizing the rate of change of the Hamiltonian. Closed form solutions are found for a constant adiabatic measure for all the cycle segments. We have identified a family of quantized frictionless cycles with increasing cycle times. These cycles minimize the entropy production. Such frictionless cycles are able to cool to $T_c=0$. External noise on the controls eliminates these frictionless cycles. The influence of phase and amplitude noise on the demagnetization and magnetization segments is explicitly derived. An extensive numerical study of optimal cooling cycles was carried out which showed that at sufficiently low temperature the noise always dominates restricting the minimum temperature.

Tova Feldmann; Ronnie Kosloff

2009-06-04T23:59:59.000Z

230

Oil cooled, hermetic refrigerant compressor  

DOE Patents (OSTI)

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler and is then delivered through the shell to the top of the motor rotor where most of it is flung radially outwardly within the confined space provided by the cap which channels the flow of most of the oil around the top of the stator and then out to a multiplicity of holes to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator from which the suction gas passes by a confined path in pipe to the suction plenum and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum. 3 figs.

English, W.A.; Young, R.R.

1985-05-14T23:59:59.000Z

231

Oil cooled, hermetic refrigerant compressor  

DOE Patents (OSTI)

A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler 18 and is then delivered through the shell to the top of the motor rotor 24 where most of it is flung radially outwardly within the confined space provided by the cap 50 which channels the flow of most of the oil around the top of the stator 26 and then out to a multiplicity of holes 52 to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber 58 to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole 62 also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator 68 from which the suction gas passes by a confined path in pipe 66 to the suction plenum 64 and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum 64.

English, William A. (Murrysville, PA); Young, Robert R. (Murrysville, PA)

1985-01-01T23:59:59.000Z

232

Novel materials for laser refrigeration  

SciTech Connect

The status of optical refrigeration of rare-earth-doped solids is reviewed, and the various factors that limit the performance of current laser-cooling materials are discussed. Efficient optical refrigeration is possible in materials for which {Dirac_h}{omega}{sub max} < E{sub p}/8, where {Dirac_h}{omega}{sub max} is the maximum phonon energy of the host material and E{sub p} is the pump energy of the rare-earth dopant. Transition-metal and OH{sup -}impurities at levels >100 ppb are believed to be the main factors for the limited laser-cooling performance in current materials. The many components of doped ZBLAN glass pose particular processing challenges. Binary fluoride glasses such as YF{sub 3}-LiF are considered as alternatives to ZBLAN. The crystalline system KPb{sub 2}CI{sub 5} :Dy{sup 3+} is identified as a prime candidate for high-efficiency laser cooling.

Hehlen, Markus P [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

233

Design of fluid film journal bearings containing continuous 3D fluid pathways which are formed by wrapping a sheet containing 2D through-cut features  

E-Print Network (OSTI)

The purpose of this research was to generate the knowledge required to: (1) design and manufacture fluid film bearings that do not require precision machining processes during fabrication, but rather gain their precision ...

Winter, Amos Greene, 1979-

2005-01-01T23:59:59.000Z

234

Refrigerant Phase-Change Stirling-Cycle Solar Power Towers  

Science Conference Proceedings (OSTI)

This paper firstly introduces the principles of Refrigerant Phase-Change Stirling-Cycle solar power towers This heat engines use solar reservoire. When the refrigerant in an engine cylinder absorbs heat from high-temperature heat sources, refrigerant ... Keywords: refrigerant phase-change cycle, heat engines, solar power tower, finite-time thermodynamics

Dezhong Huang

2011-01-01T23:59:59.000Z

235

Control system for heat exchangers fans in a refrigeration system  

Science Conference Proceedings (OSTI)

The paper presents a method for controlling evaporator and condenser fans in a refrigeration system. The refrigeration system includes a refrigerant circuit defined by a compressor, a condenser, a throttling device, and an evaporator. The system includes ... Keywords: controlling, fan, refrigeration system, variable frequency drive unit

Cristian Iosifescu; Valeriu Damian; C?lin Ciufudean

2010-05-01T23:59:59.000Z

236

Cutting assembly. [Patent application  

DOE Patents (OSTI)

A mining auger comprises a cutting head carried at one end of a tubular shaft and a plurality of wall segments which in a first position thereof are disposed side by side around said shaft and in a second position thereof are disposed oblique to said shaft. A vane projects outwardly from each wall segment. When the wall segments are in their first position, the vanes together form a substantially continuous helical wall. A cutter is mounted on the peripheral edge of each of the vanes. When the wall segments are in their second position, the cutters on the vanes are disposed radially outward from the perimeter of the cutting head.

Treuhaft, M.B.; Oser, M.S.

1981-06-25T23:59:59.000Z

237

Dual-circuit, multiple-effect refrigeration system and method  

DOE Patents (OSTI)

A dual circuit absorption refrigeration system comprising a high temperature single-effect refrigeration loop and a lower temperature double-effect refrigeration loop separate from one another and provided with a double-condenser coupling therebetween. The high temperature condenser of the single-effect refrigeration loop is double coupled to both of the generators in the double-effect refrigeration loop to improve internal heat recovery and a heat and mass transfer additive such as 2-ethyl-1-hexanol is used in the lower temperature double-effect refrigeration loop to improve the performance of the absorber in the double-effect refrigeration loop.

DeVault, Robert C. (Knoxville, TN)

1995-01-01T23:59:59.000Z

238

Bearing construction for refrigeration compresssor  

DOE Patents (OSTI)

A hermetic refrigeration compressor has a cylinder block and a crankshaft rotatable about a vertical axis to reciprocate a piston in a cylinder on the cylinder block. A separate bearing housing is secured to the central portion of the cylinder block and extends vertically along the crankshaft, where it carries a pair of roller bearings to journal the crankshaft. The crankshaft has a radially extending flange which is journaled by a thrust-type roller bearing above the bearing housing to absorb the vertical forces on the crankshaft so that all three of the roller bearings are between the crankshaft and the bearing housing to maintain and control the close tolerances required by such bearings.

Middleton, Marc G. (Wyoming, MI); Nelson, Richard T. (Worthington, OH)

1988-01-01T23:59:59.000Z

239

New Regenerative Cycle for Vapor Compression Refrigeration  

SciTech Connect

The main objective of this project is to confirm on a well-instrumented prototype the theoretically derived claims of higher efficiency and coefficient of performance for geothermal heat pumps based on a new regenerative thermodynamic cycle as comparing to existing technology. In order to demonstrate the improved performance of the prototype, it will be compared to published parameters of commercially available geothermal heat pumps manufactured by US and foreign companies. Other objectives are to optimize the design parameters and to determine the economic viability of the new technology. Background (as stated in the proposal): The proposed technology closely relates to EERE mission by improving energy efficiency, bringing clean, reliable and affordable heating and cooling to the residential and commercial buildings and reducing greenhouse gases emission. It can provide the same amount of heating and cooling with considerably less use of electrical energy and consequently has a potential of reducing our nations dependence on foreign oil. The theoretical basis for the proposed thermodynamic cycle was previously developed and was originally called a dynamic equilibrium method. This theory considers the dynamic equations of state of the working fluid and proposes the methods for modification of T-S trajectories of adiabatic transformation by changing dynamic properties of gas, such as flow rate, speed and acceleration. The substance of this proposal is a thermodynamic cycle characterized by the regenerative use of the potential energy of two-phase flow expansion, which in traditional systems is lost in expansion valves. The essential new features of the process are: (1) The application of two-step throttling of the working fluid and two-step compression of its vapor phase. (2) Use of a compressor as the initial step compression and a jet device as a second step, where throttling and compression are combined. (3) Controlled ratio of a working fluid at the first and second step of compression. In the proposed system, the compressor compresses the vapor only to 50-60% of the final pressure, while the additional compression is provided by a jet device using internal potential energy of the working fluid flow. Therefore, the amount of mechanical energy required by a compressor is significantly reduced, resulting in the increase of efficiency (either COP or EER). The novelty of the cycle is in the equipment and in the way the multi-staging is accomplished. The anticipated result will be a new refrigeration system that requires less energy to accomplish a cooling task. The application of this technology will be for more efficient designs of: (1) Industrial chillers, (2) Refrigeration plants, (3) Heat pumps, (4) Gas Liquefaction plants, (5) Cryogenic systems.

Mark J. Bergander

2005-08-29T23:59:59.000Z

240

ADVANCED CUTTINGS TRANSPORT STUDY  

Science Conference Proceedings (OSTI)

ACTS flow loop is now operational under elevated pressure and temperature. Currently, experiments with water under pressure and temperature are being conducted. Based on the analysis of Fann 70 data, empirical correlations defining the shear stress as a function of temperature, pressure and the shear rate have been developed for Petrobras synthetic drilling fluids. PVT equipment has been modified for testing Synthetic drilling fluids. Initial calibration tests have been conducted by using water. Currently, the base oil of the Petrobras synthetic drilling fluid is being tested. Foam flow experiments have been conducted. Currently, more experiments are being conducted while data are being analyzed to characterize the rheology of the foam. Cuttings transport experiments have been conducted using air, water and cuttings. Preliminary results have shown that it may not be possible to avoid cuttings bed deposition under any practical combination of air and water flow rates. Foam stability analyses have been conducted. Effects of salt and oil concentration on the foam stability have been investigated. A software for controlling the data sampling and data storage during cuttings monitoring process have been developed.

Ergun Kuru; Stefan Miska; Nicholas Takach; Kaveh Ashenayi; Gerald Kane; Len Volk; Mark Pickell; Mike Volk; Barkim Demirdal; Affonso Lourenco; Evren Ozbayoglu; Paco Vieira; Neelima Godugu; Sri Suresh Kumar Thiroveedhula

2000-04-30T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Electron beam cutting  

DOE Patents (OSTI)

A method for the cutting of holes 20 Angstroms in diameter, or lines 20 Angstroms wide in a material having positive ionic conduction by the use of a focused electron probe is described. The holes and lines are stable under ambient conditions. 2 figs.

Mochel, M.E.; Humphreys, C.J.

1985-04-02T23:59:59.000Z

242

Electron beam cutting  

DOE Patents (OSTI)

A method for the cutting of holes 20 Angstroms in diameter, or lines 20 Angstroms wide in a material having positive ionic conduction by the use of a focused electron probe is described. The holes and lines are stable under ambient conditions.

Mochel, Margaret E. (Champaign, IL); Humphreys, Colin J. (Abingdon, GB2)

1985-04-02T23:59:59.000Z

243

Status of not-in-kind refrigeration technologies for household space conditioning, water heating and food refrigeration  

Science Conference Proceedings (OSTI)

This paper presents a review of the next generation not-in-kind technologies to replace conventional vapor compression refrigeration technology for household applications. Such technologies are sought to provide energy savings or other environmental benefits for space conditioning, water heating and refrigeration for domestic use. These alternative technologies include: thermoacoustic refrigeration, thermoelectric refrigeration, thermotunneling, magnetic refrigeration, Stirling cycle refrigeration, pulse tube refrigeration, Malone cycle refrigeration, absorption refrigeration, adsorption refrigeration, and compressor driven metal hydride heat pumps. Furthermore, heat pump water heating and integrated heat pump systems are also discussed due to their significant energy saving potential for water heating and space conditioning in households. The paper provides a snapshot of the future R&D needs for each of the technologies along with the associated barriers. Both thermoelectric and magnetic technologies look relatively attractive due to recent developments in the materials and prototypes being manufactured.

Bansal, Pradeep [ORNL; Vineyard, Edward Allan [ORNL; Abdelaziz, Omar [ORNL

2012-01-01T23:59:59.000Z

244

Small Commercial Refrigeration Incentive | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive Small Commercial Refrigeration Incentive < Back Eligibility Agricultural Commercial Industrial Institutional Nonprofit Savings Category Appliances & Electronics Commercial Lighting Lighting Maximum Rebate Incentives over $5,000 must be pre-approved Program Info Funding Source Efficiency Vermont Public Benefit Fund Expiration Date 06/30/2013 State Vermont Program Type State Rebate Program Rebate Amount Outside Air Economizers: $1,250 Evaporator Fan Motors: $20 - $100 Evaporator Fan Motor Controls: $550 Door/Frame Heater Controls: $50 per door Case Light Occupancy Controls: $40 LED Refrigerator and Freezer Case Light Fixtures: $6 - $15 per foot Energy Star Ice Machines: $50 - $75 Efficient Compressors: $200 Display Case Strip-Curtain and Continuous Covers: $6 per foot

245

Cospolich Refrigerator: Proposed Penalty (2013-CE-5314)  

Energy.gov (U.S. Department of Energy (DOE))

DOE alleged in a Notice of Proposed Civil Penalty that Cospolich Refrigerator Co, Inc. failed to certify walk-in cooler or freezer components as compliant with the energy conservation standards.

246

Refrigerator Manufacturers: Proposed Penalty (2013-CE-5341)  

Energy.gov (U.S. Department of Energy (DOE))

DOE alleged in a Notice of Proposed Civil Penalty that Refrigerator Manufacturers, LLC failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards.

247

Loveland Water & Power- Refrigerator Recycling Program  

Energy.gov (U.S. Department of Energy (DOE))

Loveland Water & Power is providing an incentive for its customers to recycle their old refrigerators. Interested customers can call the utility to arrange a time to pick up the old...

248

Elastic Metal Alloy Refrigerants: Thermoelastic Cooling  

SciTech Connect

BEETIT Project: UMD is developing an energy-efficient cooling system that eliminates the need for synthetic refrigerants that harm the environment. More than 90% of the cooling and refrigeration systems in the U.S. today use vapor compression systems which rely on liquid to vapor phase transformation of synthetic refrigerants to absorb or release heat. Thermoelastic cooling systems, however, use a solid-state materialan elastic shape memory metal alloyas a refrigerant and a solid to solid phase transformation to absorb or release heat. UMD is developing and testing shape memory alloys and a cooling device that alternately absorbs or creates heat in much the same way as a vapor compression system, but with significantly less energy and a smaller operational footprint.

2010-10-01T23:59:59.000Z

249

Refrigeration system having standing wave compressor  

DOE Patents (OSTI)

A compression-evaporation refrigeration system, wherein gaseous compression of the refrigerant is provided by a standing wave compressor. The standing wave compressor is modified so as to provide a separate subcooling system for the refrigerant, so that efficiency losses due to flashing are reduced. Subcooling occurs when heat exchange is provided between the refrigerant and a heat pumping surface, which is exposed to the standing acoustic wave within the standing wave compressor. A variable capacity and variable discharge pressure for the standing wave compressor is provided. A control circuit simultaneously varies the capacity and discharge pressure in response to changing operating conditions, thereby maintaining the minimum discharge pressure needed for condensation to occur at any time. Thus, the power consumption of the standing wave compressor is reduced and system efficiency is improved.

Lucas, Timothy S. (Glen Allen, VA)

1992-01-01T23:59:59.000Z

250

PhD student in Energy Technology, specifically in Magnetic Refrigeration The School of Industrial Engineering and Management at the Royal Institute of  

E-Print Network (OSTI)

PhD student in Energy Technology, specifically in Magnetic Refrigeration Processes The School Technology, specifically Magnetic Refrigeration Processes. KTH is the largest technical university in Sweden and the environment. Core knowledge areas include energy technology, industrial design and innovation, product

Kazachkov, Ivan

251

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network (OSTI)

Amarnath, M. Blatt, Variable refrigerant flow: where, why,simulation in the variable refrigerant flow air-conditioningsimulation of the variable refrigerant flow air conditioning

Hong, Tainzhen

2010-01-01T23:59:59.000Z

252

Opportunities for Energy Efficiency and Automated Demand Response in Industrial Refrigerated Warehouses in California  

E-Print Network (OSTI)

D. Brown (2004). Industrial Refrigeration Best PracticesD. Brown (2004). Industrial Refrigeration Best Practicesoutlet common in industrial refrigeration Source: Wilcox,

Lekov, Alex

2009-01-01T23:59:59.000Z

253

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network (OSTI)

refrigeration products use vapor compression technology toicemakers and non-vapor compression refrigerators and+4.5) million non-vapor compression refrigerators in U.S.

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

254

Working Fluids Low Global Warming Potential Refrigerants  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Working Fluids Low GWP Working Fluids Low GWP Refrigerants - CRADA Ed Vineyard Oak Ridge National Laboratory vineyardea@ornl.gov (865) 574-0576 3 April 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: - High GWP refrigerants increase CO 2 equivalent emissions for HVAC&R equipment - Low GWP alternatives may increase energy consumption, introduce safety risks, require significant modifications to equipment, and have higher costs

255

Combined cold compressor/ejector helium refrigerator  

DOE Patents (OSTI)

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, Donald P. (Southold, NY)

1985-01-01T23:59:59.000Z

256

Working Fluids Low Global Warming Potential Refrigerants  

NLE Websites -- All DOE Office Websites (Extended Search)

Working Fluids Low GWP Working Fluids Low GWP Refrigerants - CRADA Ed Vineyard Oak Ridge National Laboratory vineyardea@ornl.gov (865) 574-0576 3 April 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: - High GWP refrigerants increase CO 2 equivalent emissions for HVAC&R equipment - Low GWP alternatives may increase energy consumption, introduce safety risks, require significant modifications to equipment, and have higher costs

257

ARI delegation to Japan on Alternative Refrigerants  

SciTech Connect

Researchers from ARI member companies spoke at the International Conference on Alternative Refrigerants in Tokyo and visited several Japanese organizations for the purpose of exchanging information on alternative refrigerants. The specific purpose of the meetings was to review the methods being utilized to screen alternatives to CFCs and HCFCs: materials compatibility screening methods, lubricant testing techniques, as well as flammability studies. A list of papers presented at the conference is included.

Not Available

1993-02-01T23:59:59.000Z

258

BNL Refrigerant Overview Presentation to the  

E-Print Network (OSTI)

0.25 4700 Cold boxes, environmental chambers R-718 Water 212 0 N/A Steam-driven absorption chiller 4750 Older centrifugal chillers (>200 tons) R-12 CFC -20 1 10900 Old refrigerators and vehicle A/C R-13/C mach. R-123 HCFC 81 1.3 77 Newer centrifugal chillers (>200 tons) R-134a HFC -15 0 1430 Refrigerators

Homes, Christopher C.

259

Combined cold compressor/ejector helium refrigerator  

DOE Patents (OSTI)

A refrigeration apparatus having an ejector operatively connected with a cold compressor to form a two-stage pumping system. This pumping system is used to lower the pressure, and thereby the temperature of a bath of boiling refrigerant (helium). The apparatus as thus arranged and operated has substantially improved operating efficiency when compared to other processes or arrangements for achieving a similar low pressure.

Brown, D.P.

1984-06-05T23:59:59.000Z

260

Energy Efficient Operation of Ammonia Refrigeration Systems  

SciTech Connect

Ammonia refrigeration systems typically offer many energy efficiency opportunities because of their size and complexity. This paper develops a model for simulating single-stage ammonia refrigeration systems, describes common energy saving opportunities, and uses the model to quantify those opportunities. The simulation model uses data that are typically available during site visits to ammonia refrigeration plants and can be calibrated to actual consumption and performance data if available. Annual electricity consumption for a base-case ammonia refrigeration system is simulated. The model is then used to quantify energy savings for six specific energy efficiency opportunities; reduce refrigeration load, increase suction pressure, employ dual suction, decrease minimum head pressure set-point, increase evaporative condenser capacity, and reclaim heat. Methods and considerations for achieving each saving opportunity are discussed. The model captures synergistic effects that result when more than one component or parameter is changed. This methodology represents an effective method to model and quantify common energy saving opportunities in ammonia refrigeration systems. The results indicate the range of savings that might be expected from common energy efficiency opportunities.

Mohammed, Abdul Qayyum [University of Dayton, Ohio; Wenning, Thomas J [ORNL; Sever, Franc [University of Dayton, Ohio; Kissock, Professor Kelly [University of Dayton, Ohio

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Global warming impacts of ozone-safe refrigerants and refrigeration, heating, and air-conditioning technologies  

SciTech Connect

International agreements mandate the phase-out of many chlorine containing compounds that are used as the working fluid in refrigeration, air-conditioning, and heating equipment. Many of the chemical compounds that have been proposed, and are being used in place of the class of refrigerants eliminated by the Montreal Protocol are now being questioned because of their possible contributions to global warming. Natural refrigerants are put forth as inherently superior to manufactured refrigerants because they have very low or zero global warming potentials (GWPs). Questions are being raised about whether or not these manufactured refrigerants, primarily hydrofluorocarbons (HFCs), should be regulated and perhaps phased out in much the same manner as CFCs and HCFCs. Several of the major applications of refrigerants are examined in this paper and the results of an analysis of their contributions to greenhouse warming are presented. Supermarket refrigeration is shown to be an application where alternative technologies have the potential to reduce emissions of greenhouse gases (GHG) significantly with no clear advantage to either natural or HFC refrigerants. Mixed results are presented for automobile air conditioners with opportunities to reduce GHG emissions dependent on climate and comfort criteria. GHG emissions for hermetic and factory built systems (i.e. household refrigerators/freezers, unitary equipment, chillers) are shown to be dominated by energy use with much greater potential for reduction through efficiency improvements than by selection of refrigerant. The results for refrigerators also illustrate that hydrocarbon and carbon dioxide blown foam insulation have lower overall effects on GHG emissions than HFC blown foams at the cost of increased energy use.

Fischer, S.; Sand, J.; Baxter, V.

1997-12-01T23:59:59.000Z

262

Cross Cutting Analysis  

NLE Websites -- All DOE Office Websites (Extended Search)

Cross Cutting Analysis Cross Cutting Analysis June 3, 2003 Hydrogen Coordination Meeting Ed Schmetz Portfolio Manager Office of Coal Fuels and Industrial Systems Natural Gas and Coal Derived Hydrogen FCV System Analysis * Two scenarios were developed to estimate the impact of natural gas and coal-derived hydrogen in fuel cell vehicles (FCVs) * Case 1 evaluated the impact of 50 million vehicles * Case 2 evaluated the impact of 100 million vehicles * Purpose was to evaluate the impact on: * Fossil fuel demand * CO 2 emissions * Criteria pollutants * Energy consumption/security * Number and cost of hydrogen plants needed Hydrogen FCV System Analysis Fleet Assumptions 27.5 12.5 10 55 25 20 0 25 50 75 100 Case 1- 50 MM LDVs Case 2- 100 MM LDVs Light Duty Vehicles, By Type in Millions LDT2 LDT1 PC * Case 1 -

263

Experimental and cost analyses of a one kilowatt-hour/day domestic refrigerator-freezer  

SciTech Connect

Over the past ten years, government regulations for energy standards, coupled with the utility industry`s promotion of energy-efficient appliances, have prompted appliance manufacturers to reduce energy consumption in refrigerator-freezers by approximately 40%. Global concerns over ozone depletion have also required the appliance industry to eliminate CFC-12 and CFC-11 while concurrently improving energy efficiency to reduce greenhouse emissions. In response to expected future regulations that will be more stringent, several design options were investigated for improving the energy efficiency of a conventionally designed, domestic refrigerator-freezer. The options, such as cabinet and door insulation improvements and a high-efficiency compressor were incorporated into a prototype refrigerator-freezer cabinet and refrigeration system. Baseline energy consumption of the original 1996 production refrigerator-freezer, along with cabinet heat load and compressor calorimeter test results, were extensively documented to provide a firm basis for experimentally measured energy savings. The goal for the project was to achieve an energy consumption that is 50% below in 1993 National Appliance Energy Conservation Act (NAECA) standard for 20 ft{sup 3} (570 l) units. Based on discussions with manufacturers to determine the most promising energy-saving options, a laboratory prototype was fabricated and tested to experimentally verify the energy consumption of a unit with vacuum insulation around the freezer, increased door thicknesses, a high-efficiency compressor, a low wattage condenser fan, a larger counterflow evaporator, and adaptive defrost control.

Vineyard, E.A.; Sand, J.R.

1997-05-01T23:59:59.000Z

264

Low-GWP Refrigerants Research Project | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Emerging Technologies » Low-GWP Refrigerants Research Project Emerging Technologies » Low-GWP Refrigerants Research Project Low-GWP Refrigerants Research Project The U.S. Department of Energy is currently conducting research into low global warming potential (GWP) refrigerants. As concerns about climate change intensify, it is becoming increasingly clear that suitable low-GWP refrigerants will be needed for both new and existing residential and commercial heating, ventilation, air conditioning, and refrigeration (HVAC&R) equipment. Project Description This project seeks to develop alternative refrigerants for HVAC&R equipment. The overall environmental impacts of alternative refrigerants will be assessed using a life cycle climate performance model that accounts for direct emissions associated with refrigerant leaks and indirect

265

Estimates of Refrigerator Loads in Public Housing Based on Metered Consumption Data  

SciTech Connect

The New York Power Authority (NYPA), the New York City Housing Authority (NYCHA), and the U.S. Departments of Housing and Urban Development (HUD) and Energy (DOE) have joined in a project to replace refrigerators in New York City public housing with new, highly energy-efficient models. This project laid the ground work for the Consortium for Energy Efficiency (CEE) and DOE to enable housing authorities throughout the United States to bulk-purchase energy-efficient appliances. DOE helped develop and plan the program through the ENERGY STAR@ Partnerships program conducted by its Pacific Nofiwest National Laboratory (PNNL). PNNL was subsequently asked to conduct the savings evahations for 1996 and 1997. PNNL designed the metering protocol and occupant survey, supplied and calibrated the metering equipment, and managed and analyzed the data. The 1996 metering study of refrigerator energy usage in New York City public housing (Pratt and Miller 1997) established the need and justification for a regression-model-based approach to an energy savings estimate. The need originated in logistical difficulties associated with sampling the population and pen?orming a stratified analysis. Commonly, refrigerators[a) with high representation in the popula- tion were missed in the sampling schedule, leaving significant holes in the sample and difficulties for the stratified anrdysis. The just{jfcation was found in the fact that strata (distinct groups of identical refrigerators) were not statistically distinct in terms of their label ratio (ratio of metered consumption to label rating). This finding suggested a general regression model could be used to represent the consumption of all refrigerators in the population. In 1996 a simple two-coefficient regression model, a function of only the refrigerator label rating, was developed and used to represent the existing population of refrigerators. A key concept used in the 1997 study grew from findings in a small number of apartments metered in 1996 with a detailed protocol. Fifteen-minute time-series data of ambient and compartment temperatures and refrigerator power were analyzed and demonstrated the potential for reducing power records into three components. This motivated the development of an analysis process to divide the metered consumption into baseline load, occupant-associated load, and defrosting load. The baseline load is the consumption that would occur if the refrigerator were on but had no occupant usage load (no door- opening events) and the defrosting mechanism was disabled. The motivation behind this component reduction process was the hope that components could be more effectively modeled than the total. We reasoned that the components would lead to abetter (more general and more significant) understanding of the relationships between consumption, the characteristics of the refrigerator, and its operating environment.

JD Miller; RG Pratt

1998-09-11T23:59:59.000Z

266

Well simulation using Refrigerant 114  

DOE Green Energy (OSTI)

A simple method for the investigation of thermodynamic (substance) similarity in the two-phase domain is introduced based on the assumptions of a simplified model fluid. According to this method, the investigation of the conditions for thermodynamic similarity between substances in the two-phase region reveals the important role the latent heat of evaporation (h/sub fg/) plays in the definition of the property scales. These greatly influence the dynamic and geometric similarity of the process under investigation. The introduction of the thermodynamic similarity property scales into the energy conservation equations for a certain process (e.g., flow up a geothermal well) brings forth a thermodynamic length scale and kinetic energy scale. Refrigerant 114 has been examined for similarity with water substance according to this method and found to be adequate for geothermal well simulation in the laboratory. Low pressures and temperatures and a substantial reduction of mass flow rates and geometric scales are a few of the advantages of using R114 for such experiments.

Nikitopoulos, D.E.; Dickinson, D.A.; DiPippo, R.; Maeder, P.F.

1984-06-01T23:59:59.000Z

267

DOE Closes Investigation of Arcelik's Blomberg Refrigerator | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Arcelik's Blomberg Refrigerator Arcelik's Blomberg Refrigerator DOE Closes Investigation of Arcelik's Blomberg Refrigerator September 1, 2010 - 4:37pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Arcelik's Blomberg refrigerator-freezer model # BRFB1450. The Department opened this investigation based on a complaint. DOE subpoenaed information from Arcelik, reviewed Arcelik's response, and performed its own testing of this model. Based on our investigation and test results, DOE has determined this model to be compliant with federal energy conservation standards. Notice of Compliance Determination Addthis Related Articles DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations DOE Closes Investigation of Whirlpool's Maytag Refrigerator

268

Comparison of Several Eco-Friendly Refrigeration Technologies  

E-Print Network (OSTI)

In this paper, the operation principles, thermodynamics characteristics, and technical practicability were compared between thermoelectric refrigeration, magnetic refrigeration and adsorption refrigeration. The TE refrigeration is the most well-developed, applicable and competitive technology. Three eco-friendly refrigeration systems are increasingly getting attention, especially in a day with increasingly energy and environmental crises. In summary, thermoelectric refrigeration possesses the following superiorities: a longer developmental period, more perfect techniques, increasing applications, a larger range of refrigerating capacity, and a better economic property in small refrigerating capacity. Thermoelectric refrigeration cannot be replaced in special fields, and its applications have received more and more attention in recovering waste heat. Magnetic refrigeration has been widely applied in lower temperature regions; its application in middle temperature regions is juvenile. In particular, there is no application of this technique in high temperature regions. Adsorption refrigeration is practical only in near room temperatures. Its advantage is that it can be used in some fields where conventional refrigeration cannot be applied, such as in the application of solar energy, geothermal energy, and other renewable energy, and the recovery of residual and waste heat.? Supported by the Young Foundation of Central South University of Forestry & Technology (06002A) The disadvantages are as follows: the cost is expensive, no practical technique is available at present, and thus, it possesses no general superiority versus other refrigeration technologies.

Tang, C.; Luo, Q.; Li, X.; Zhu, X.

2006-01-01T23:59:59.000Z

269

Cuttings Analysis | Open Energy Information  

Open Energy Info (EERE)

Cuttings Analysis Cuttings Analysis Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: Cuttings Analysis Details Activities (36) Areas (28) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Lab Analysis Techniques Exploration Sub Group: Rock Lab Analysis Parent Exploration Technique: Rock Lab Analysis Information Provided by Technique Lithology: Cuttings are used to define lithology Stratigraphic/Structural: Hydrological: Thermal: Cost Information Low-End Estimate (USD): 1,000.00100,000 centUSD 1 kUSD 1.0e-3 MUSD 1.0e-6 TUSD / 100 feet cut Median Estimate (USD): 4,000.00400,000 centUSD 4 kUSD 0.004 MUSD 4.0e-6 TUSD / 100 feet cut High-End Estimate (USD): 10,000.001,000,000 centUSD 10 kUSD 0.01 MUSD 1.0e-5 TUSD / 100 feet cut Time Required

270

ADVANCED CUTTINGS TRANSPORT STUDY  

DOE Green Energy (OSTI)

We have tested the loop elevation system. We raised the mast to approximately 25 to 30 degrees from horizontal. All went well. However, while lowering the mast, it moved laterally a couple of degrees. Upon visual inspection, severe spalling of the concrete on the face of the support pillar, and deformation of the steel support structure was observed. At this time, the facility is ready for testing in the horizontal position. A new air compressor has been received and set in place for the ACTS test loop. A new laboratory has been built near the ACTS test loop Roughened cups and rotors for the viscometer (RS300) were obtained. Rheologies of aqueous foams were measured using three different cup-rotor assemblies that have different surface roughness. The relationship between surface roughness and foam rheology was investigated. Re-calibration of nuclear densitometers has been finished. The re-calibration was also performed with 1% surfactant foam. A new cuttings injection system was installed at the bottom of the injection tower. It replaced the previous injection auger. A mechanistic model for cuttings transport with aerated mud has been developed. Cuttings transport mechanisms with aerated water at various conditions were experimentally investigated. A total of 39 tests were performed. Comparisons between the model predictions and experimental measurements show a satisfactory agreement. Results from the ultrasonic monitoring system indicated that we could distinguish between different sand levels. We also have devised ways to achieve consistency of performance by securing the sensors in the caps in exactly the same manner as long as the sensors are not removed from the caps. A preliminary test was conducted on the main flow loop at 100 gpm flow rate and 20 lb/min cuttings injection rate. The measured bed thickness using the ultrasonic method showed a satisfactory agreement with nuclear densitometer readings. Thirty different data points were collected after the test section was put into liquid holdup mode. Readings indicated 2.5 to 2.7 inches of sand. The corresponding nuclear densitometers readings were between 2.5 and 3.1 inches. Lab tests were conducted to check an on-line viewing system. Sharp images were obtained through a CCD camera with the use of a ring light or fiber light. A prototype device for measuring the average bubble size for the foam generator-viscometer was constructed from a 1/2 inch fitting. The new windowed cell has been received and installed on the ACTF Bubble Characterization Cart.

Stefan Miska; Nicholas Takach; Kaveh Ashenayi

2004-07-31T23:59:59.000Z

271

Ammonia usage in vapor compression for refrigeration and air-conditioning in the United States  

SciTech Connect

The impending phaseout of CFCs and HCFCs has led to a worldwide search for refrigerants that can provide equivalent performance while not damaging the environment. Long used as a working fluid in industrial and large-scale refrigeration, ammonia provides high efficiency, low initial cost, and no detrimental impact to the environment. However, its toxicity and flammability, along with technical considerations and increased operating costs, deter its use in many refrigeration and cooling applications. Utilization of ammonia in applications where its safety considerations and technical concerns can be addressed provides the best growth opportunity for adoption as a replacement refrigerant. Applications such as district or large-scale cooling, thermal storage, packaged systems, and combined systems hold promise for increased usage of ammonia. Ongoing research and development are providing solutions to technical considerations, and innovations in safety and containment of ammonia are addressing those particular concerns, but code restrictions and regulations present the greatest barrier to wider adoption of ammonia as an alternate refrigerant in the US To encourage wider use, future efforts will need to continue on improved safety and more efficient design, along with an increased emphasis on educating and informing industry and the public about the advantages ammonia and the factors restricting its use.

Fairchild, P.D.; Baxter, V.D.

1995-12-31T23:59:59.000Z

272

Japanese Refrigerators : A Field Performance Analysis : Field Inspection Data, Screening and Compilation.  

SciTech Connect

The Pacific Northwest Electric Power Planning and Conservation Act, signed into law December 5, 1980, mandated regionwide energy conservation practices. Under the act, BPA must identify and implement cost-effective electric energy options and programs for the Pacific Northwest. The Residential Technology Section in the Division of Resource Management supports current residential energy conservation programs and designs and conducts various research and development projects, of which this project is one. Laboratory test procedures used by the Japanese had shown their refrigerators to be about 50 percent more efficient than American-made refrigerators. A previous BPA study tested 12 Japanese refrigerators according to the USDOE laboratory procedure. This study showed that when tested to the DOE procedure, the Japanese refrigerators used about 43 percent more energy than when tested by the Japanese procedure. This study compared in-home energy use of 12 Japanese refrigerators identical to those in the laboratory test to both the Japanese and USDOE laboratory tests. 2 figs., 3 tabs.

Nelson, Peter E.

1989-11-01T23:59:59.000Z

273

Ongoing Commissioning of a high efficiency supermarket with a ground coupled carbon dioxide refrigeration plant  

E-Print Network (OSTI)

A significant reduction in the energy consumption and greenhouse gas emissions of supermarkets can be reached by the combination of several innovative components and the continuous optimization of their operation. A German food retail chain developed a new supermarket concept combining several innovative solutions for the refrigeration, lighting and heating/ventilation with the goal to reduce the energy consumption by about 30% compared to a standard subsidiary. A highly insulated building envelope, the use of daylight and covered refrigeration units contribute jointly to reach the goals. The key component of the concept is a carbon dioxide refrigeration plant with waste heat recovery. To reduce the efficiency losses in supercritical operation, carbon dioxide is cooled through a borehole heat exchanger using the ground as a heat sink. In the paper the design concept, the results of simulation studies and of the first monitoring year are presented and discussed.

Rehault, N.; Kalz, D.

2012-01-01T23:59:59.000Z

274

Energy Consumption of Refrigerators in Ghana - Outcomes of Household  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Consumption of Refrigerators in Ghana - Outcomes of Household Energy Consumption of Refrigerators in Ghana - Outcomes of Household Surveys Speaker(s): Essel Ben Hagan Date: July 12, 2007 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Robert Van Buskirk Galen Barbose As part of activities to develop refrigerator efficiency standards regulations in Ghana, a national survey on the energy consumption of refrigerators and refrigerator-freezers has been conducted. The survey covered 1000 households in urban, peri-urban and rural communities in various parts of the country. The survey found that, on average, refrigerators and refrigerator-freezers in Ghana use almost three times what is allowed by minimum efficiency standards in the U.S., and a few refrigerators had energy use at levels almost ten times the U.S.

275

Loveland Water and Power - Refrigerator Recycling Program | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Refrigerator Recycling Program Refrigerator Recycling Program Loveland Water and Power - Refrigerator Recycling Program < Back Eligibility Residential Savings Category Appliances & Electronics Maximum Rebate Limit one rebate per account per year Program Info State Colorado Program Type Utility Rebate Program Rebate Amount Refrigerator and Freezer Recycling: $35 Loveland Water and Power is providing an incentive for its customers to recycle their old refrigerators. Interested customers can call the utility to arrange a time to pick up the old refrigerator. The old refrigerator should be brought outside but remain plugged in so the utility can make it is in working condition. the utility will then take the refrigerator to a recycling facility and issue a $35 bill credit. Other Information

276

Refrigerator Standards Save Consumers $ Billions | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Refrigerator Standards Save Consumers $ Billions Refrigerator Standards Save Consumers $ Billions Refrigerator Standards Save Consumers $ Billions March 5, 2013 - 10:35am Addthis Refrigerator Standards Refrigerator Standards Refrigerator technology has come a long way since Dr. John Gorrie (1803 - 1855), a forward-looking inventor, was granted U. S. Patent #8080 for mechanical refrigeration in 1851. In those days, ice was expensive, if it was even available: Blocks of natural ice were carved from frozen lakes and rivers and stored in special warehouses under layers of sawdust for insulation. By the 1890s, pollution and sewage dumping caused by population growth compromised sources of pure, natural ice, threatening the brewing, meat-packing, and dairy industries. As these and other industries sought better solutions, modern refrigeration technology started to evolve.

277

DOE Resolves Avanti Refrigerator and Freezer Civil Penalty Case  

Energy.gov (U.S. Department of Energy (DOE))

Today, the Department of Energy announced that it has resolved thecivil penalty action against Mackle Company for its failure to certify that refrigerators and refrigerator-freezers sold under the...

278

VEE-0079 - In the Matter of Diversified Refrigeration, Inc.  

Energy.gov (U.S. Department of Energy (DOE))

Diversified Refrigeration, Inc. (DRI) requests a six-month exception from the 2001 energy appliance efficiency standards for built-in refrigerators that become effective July 1, 2001. As explained...

279

Thermoelectric refrigerator having improved temperature-stabilization means  

DOE Patents (OSTI)

A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized.

Falco, C.M.

1981-07-29T23:59:59.000Z

280

Proposed Methodology for LEED Baseline Refrigeration Modeling (Presentation)  

SciTech Connect

This PowerPoint presentation summarizes a proposed methodology for LEED baseline refrigeration modeling. The presentation discusses why refrigeration modeling is important, the inputs of energy models, resources, reference building model cases, baseline model highlights, example savings calculations and results.

Deru, M.

2011-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Helium-Based Soundwave Chiller: Trillium: A Helium-Based Sonic Chiller- Tons of Freezing with 0 GWP Refrigerants  

SciTech Connect

BEETIT Project: Penn State is designing a freezer that substitutes the use of sound waves and environmentally benign refrigerant for synthetic refrigerants found in conventional freezers. Called a thermoacoustic chiller, the technology is based on the fact that the pressure oscillations in a sound wave result in temperature changes. Areas of higher pressure raise temperatures and areas of low pressure decrease temperatures. By carefully arranging a series of heat exchangers in a sound field, the chiller is able to isolate the hot and cold regions of the sound waves. Penn States chiller uses helium gas to replace synthetic refrigerants. Because helium does not burn, explode or combine with other chemicals, it is an environmentally-friendly alternative to other polluting refrigerants. Penn State is working to apply this technology on a large scale.

None

2010-09-01T23:59:59.000Z

282

International Refrigeration: Proposed Penalty (2012-CE-1510)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

International Refrigeration Products International Refrigeration Products (room air conditioners) ) ) ) ) ) Case Number: 2012-CE-1510 NOTICE OF PROPOSED CIVIL PENALTY Date issued: July 9, 2012 Number of alleged violations: 5475 (365 days, 15 models) Maximum possible assessment: $1,095,000 Proposed civil penalty: $109,500 The U.S. Department of Energy ("DOE") Office of the General Counsel, Office of Enforcement, alleges that International Refrigeration Products ("IRP") has violated cettain provisions of the Energy Policy and Conservation Act, 42 U.S.C. § 6291 et seq. ("the Act"), and 10 C.P.R. § 429.12. Specifically, DOE alleges: 1. IRP has manufactured 1 a variety of Sea Breeze brand room air conditioners, including basic models WA46YR, WA48YRX, WA410YRX, WA412YRX, WH418ZRX,

283

Of Refrigerators & Regulations | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Of Refrigerators & Regulations Of Refrigerators & Regulations Of Refrigerators & Regulations February 8, 2011 - 9:29am Addthis Jesse Lee White House Director of Online Affairs Editor's Note: This entry has been cross-posted from The White House Blog. For those interested in the President's remarks to the U.S. Chamber of Commerce and his views on the shared responsibilities of government and business to the American people, our post earlier will give a suitable overview. For those interested in the details of the President's Executive Order on reviewing regulations and their impacts on the economy, Cass Sunstein's post this morning will also be of value. But the President also took a moment during his speech to put the debate over regulation in a different perspective, and to break through the false dichotomy so often

284

Energy Saving with Absorption Refrigeration Technologies  

E-Print Network (OSTI)

Absorption refrigeration technology can be an economical and cost effective means of reducing energy cost and/or improving the efficiency and output of your process. We believe the potential benefits of absorption refrigeration technology have generally been overlooked by the process industry. This paper will address the application of the lithium bromide-water cycle in various energy saving modes. A waste heat powered absorption chiller producing chilled water can reduce energy consumption in a process plant by replacing an existing mechanical refrigeration system or replacing cooling tower water with a lower temperature cooling medium at negligible increase in energy cost. A variety of waste heat sources can be used at temperatures as low as 150 F.

Davis, R. C.

1984-01-01T23:59:59.000Z

285

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

... Is this refrigerator model suitable for frozen vaccine storage? Freezer thermostat dial set to midpoint position: vaccine vial temperatures ...

2012-08-02T23:59:59.000Z

286

High Efficiency Low Emission Supermarket Refrigeration Research Project  

Energy.gov (U.S. Department of Energy (DOE))

The U.S. Department of Energy (DOE) is currently conducting research into high efficiency, low emission supermarket refrigeration technologies.

287

Toxicity Data to Determine Refrigerant Concentration Limits  

SciTech Connect

This report reviews toxicity data, identifies sources for them, and presents resulting exposure limits for refrigerants for consideration by qualified parties in developing safety guides, standards, codes, and regulations. It outlines a method to calculate an acute toxicity exposure limit (ATEL) and from it a recommended refrigerant concentration limit (RCL) for emergency exposures. The report focuses on acute toxicity with particular attention to lethality, cardiac sensitization, anesthetic and central nervous system effects, and other escape-impairing effects. It addresses R-11, R-12, R-22, R-23, R-113, R-114, R-116, R-123, R-124, R-125, R-134, R-134a, R-E134, R-141b, R-142b, R-143a, R-152a, R-218, R-227ea, R-236fa, R-245ca, R-245fa, R-290, R-500, R-502, R-600a, R-717, and R-744. It summarizes additional data for R-14, R-115, R-170 (ethane), R-C318, R-600 (n-butane), and R-1270 (propylene) to enable calculation of limits for blends incorporating them. The report summarizes the data a nd related safety information, including classifications and flammability data. It also presents a series of tables with proposed ATEL and RCL concentrations-in dimensionless form and the latter also in both metric (SI) and inch-pound (IP) units of measure-for both the cited refrigerants and 66 zerotropic and azeotropic blends. They include common refrigerants, such as R-404A, R-407C, R-410A, and R-507A, as well as others in commercial or developmental status. Appendices provide profiles for the cited single-compound refrigerants and for R-500 and R-502 as well as narrative toxicity summaries for common refrigerants. The report includes an extensive set of references.

Calm, James M.

2000-09-30T23:59:59.000Z

288

ENVIRONMENTAL ASSESSMENT FOR THE PROPOSED ENERGY CONSERVATION STANDARD FOR REFRIGERATORS, REFRIGERATOR-  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ASSESSMENT FOR THE PROPOSED ENERGY ASSESSMENT FOR THE PROPOSED ENERGY CONSERVATION STANDARD FOR REFRIGERATORS, REFRIGERATOR- , AND FREEZERS - 1. INTRODUCTION AND NEED FOR PROPOSED ACTION ental Assessment (EA) on the candidate energy conservation stand licy Act. of 1969 (NEPA), regulations of the Council on Environmentd Qu refrigerators, re€iigerator-freezers, and freezers was prepared pursuant to the National ' ederal Regulations, Parts 1500 through. 1508. The proposed energy conservation standard (Level 1) and the alternative standards are being reviewed in an energy- efficiency standards rulemaking that the Department has undertaken pursuant to the Energy Policy and Conservation Act, as amended by the National Energy Conservation Policy Act and the National Appliance Energy Consehation Act

289

Retrofitting Doors on Open Refrigerated Cases  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Retrofitting Doors on Open Retrofitting Doors on Open Refrigerated Cases William Goetzler Navigant Consulting, Inc. wgoetzler@navigant.com (781) 270-8351 April 4, 2013 BBA Refrigeration Project Team Images courtesy of REMIS AMERICA, LLC. 2 | Building Technologies Office eere.energy.gov Technology Overview Image from Investigation of Energy- Efficient Supermarket Display Cases. 2004, Oak Ridge National Laboratory. Background and Motivation * Adding doors to open cases (retrofits) greatly reduces cold air loss - 50-80% load reduction - Load reduction = system energy savings

290

REFRIGERANT-BASED PROPULSION SYSTEM FOR SMALL SPACECRAFT  

E-Print Network (OSTI)

The MR SAT spacecraft under development at UMR requires a propulsion system that can be utilized to perform orbital maneuvers and three-axis attitude control to complete its mission objective of conducting spacecraft formation flight. This thesis documents the research, analysis design and development of the cold gas propulsion system that was integrated in the MR SAT spacecraft. The basis of design and safety requirements stemmed from the AFRL University Nanosat Program competition, in which the UMR SAT project placed third out of eleven schools from across the nation. The MR SAT propulsion system was a primary feature as it implements a refrigerant (R-134a) propellant that has never been flown in space. As detailed in this thesis, through engineering modeling and laboratory testing R-134a is demonstrated to be a feasible propellant for small spacecraft. As the R-134a is stored as a saturated liquid in the tank, it was necessary to analyze the thermodynamic properties of the refrigerant and investigate phase changes for its use as a propellant. Also documented is the hardware selected and the integration into the MR SAT spacecraft, along with the laboratory testing

Carl Reiner Seubert; Dr. Kelly; O. Homan

2007-01-01T23:59:59.000Z

291

ASHRAE/NIST Refrigerants Conference International concerns about the impact of refrigerants on climate change drive the  

E-Print Network (OSTI)

ASHRAE/NIST Refrigerants Conference International concerns about the impact of refrigerants conference between ASHRAE and NIST. Supporting Organizations: NOTE: Registration closes Oct. 18 and includes conference proceedings, daily lunch and dinner Monday evening. ASHRAE Members: $425 Non

Fernández-Juricic, Esteban

292

Refrigeration needs for sustainable preservation of horticultural products  

Science Conference Proceedings (OSTI)

Fresh horticultural products are highly perishable and need refrigeration for further preservation. Refrigeration needs energy consumption with consequent economical cost and damage for the environment. The objective of the present work was to use efficiently ... Keywords: energy efficiency, food salads, halophytes, postharvest technologies, refrigeration, safe food, sustainability

Custdia Gago; Ana Rita Sousa; Miriam Julio; Graa Miguel; Dulce Antunes; Thomas Panagopoulos

2011-02-01T23:59:59.000Z

293

Literature survey of heat transfer enhancement techniques in refrigeration applications  

Science Conference Proceedings (OSTI)

A survey has been performed of the technical and patent literature on enhanced heat transfer of refrigerants in pool boiling, forced convection evaporation, and condensation. Extensive bibliographies of the technical literature and patents are given. Many passive and active techniques were examined for pure refrigerants, refrigerant-oil mixtures, and refrigerant mixtures. The citations were categorized according to enhancement technique, heat transfer mode, and tube or shell side focus. The effects of the enhancement techniques relative to smooth and/or pure refrigerants were illustrated through the discussion of selected papers. Patented enhancement techniques also are discussed. Enhanced heat transfer has demonstrated significant improvements in performance in many refrigerant applications. However, refrigerant mixtures and refrigerant-oil mixtures have not been studied extensively; no research has been performed with enhanced refrigerant mixtures with oil. Most studies have been of the parametric type; there has been inadequate examination of the fundamental processes governing enhanced refrigerant heat transfer, but some modeling is being done and correlations developed. It is clear that an enhancement technique must be optimized for the refrigerant and operating condition. Fundamental processes governing the heat transfer must be examined if models for enhancement techniques are to be developed; these models could provide the method to optimize a surface. Refrigerant mixtures, with and without oil present, must be studied with enhancement devices; there is too little known to be able to estimate the effects of mixtures (particularly NARMs) with enhanced heat transfer. Other conclusions and recommendations are offered.

Jensen, M.K.; Shome, B. [Rensselaer Polytechnic Inst., Troy, NY (United States). Dept. of Mechanical Engineering, Aeronautical Engineering and Mechanics

1994-05-01T23:59:59.000Z

294

Control method for mixed refrigerant based natural gas liquefier  

DOE Patents (OSTI)

In a natural gas liquefaction system having a refrigerant storage circuit, a refrigerant circulation circuit in fluid communication with the refrigerant storage circuit, and a natural gas liquefaction circuit in thermal communication with the refrigerant circulation circuit, a method for liquefaction of natural gas in which pressure in the refrigerant circulation circuit is adjusted to below about 175 psig by exchange of refrigerant with the refrigerant storage circuit. A variable speed motor is started whereby operation of a compressor is initiated. The compressor is operated at full discharge capacity. Operation of an expansion valve is initiated whereby suction pressure at the suction pressure port of the compressor is maintained below about 30 psig and discharge pressure at the discharge pressure port of the compressor is maintained below about 350 psig. Refrigerant vapor is introduced from the refrigerant holding tank into the refrigerant circulation circuit until the suction pressure is reduced to below about 15 psig, after which flow of the refrigerant vapor from the refrigerant holding tank is terminated. Natural gas is then introduced into a natural gas liquefier, resulting in liquefaction of the natural gas.

Kountz, Kenneth J. (Palatine, IL); Bishop, Patrick M. (Chicago, IL)

2003-01-01T23:59:59.000Z

295

Overview of CFC replacement issues for household refrigeration  

Science Conference Proceedings (OSTI)

In 1974, the famous ozone depletion theory of Rowland and Molina claimed that chlorofluorocarbons (CFCs) diffuse into the stratosphere where they are broken down by photolysis to release chlorine atoms that catalytically destroy ozone. Although the understanding of the science is still imperfect, there is little doubt that CFCs play a major role in the Antarctic ozone hole phenomenon and the decline in ozone observed in the rest of the world. Another issue that has become increasingly important is the potential of CFCs to change the earth's temperature and to modify the climate. While the main impact in global warming is made by increased concentrations of carbon dioxide, CFCs and other trace gases also contribute to this effect. In an effort to respond to the global environmental threat, a CFC protocol was adopted during a diplomatic conference in Montreal. This document, known as the Montreal Protocol, was ratified in 1988 and put into effect on January 1, 1989. In accordance with Article 6 of the Montreal Protocol, the countries that signed the agreement shall periodically assess the control measures provided for in the Protocol. As part of that assessment process, household refrigeration was investigated to determine the status of CFC-12 replacements. The conclusion was that much progress has been made towards finding a suitable replacement. Compressors designed for HFC-134a have efficiencies comparable to those for CFC-12 and acceptable reliability tests have been obtained with ester lubricants. In addition, other replacements such as R-152a and refrigerant mixtures exist, but will require more study. Cycle options, such as the Stirling cycle, may be viable, but are further out in the future. The impact of new refrigerants is expected to result in elimination of CFC-12 consumption in developed countries by 1997 and in developing countries by 2005.

Vineyard, E.A. (Oak Ridge National Lab., TN (United States)); Roke, L. (Fisher and Paykel, Auckland (New Zealand)); Hallett, F. (Frigidaire, Washington, DC (United States))

1991-01-01T23:59:59.000Z

296

Overview of CFC replacement issues for household refrigeration  

Science Conference Proceedings (OSTI)

In 1974, the famous ozone depletion theory of Rowland and Molina claimed that chlorofluorocarbons (CFCs) diffuse into the stratosphere where they are broken down by photolysis to release chlorine atoms that catalytically destroy ozone. Although the understanding of the science is still imperfect, there is little doubt that CFCs play a major role in the Antarctic ozone hole phenomenon and the decline in ozone observed in the rest of the world. Another issue that has become increasingly important is the potential of CFCs to change the earth`s temperature and to modify the climate. While the main impact in global warming is made by increased concentrations of carbon dioxide, CFCs and other trace gases also contribute to this effect. In an effort to respond to the global environmental threat, a CFC protocol was adopted during a diplomatic conference in Montreal. This document, known as the Montreal Protocol, was ratified in 1988 and put into effect on January 1, 1989. In accordance with Article 6 of the Montreal Protocol, the countries that signed the agreement shall periodically assess the control measures provided for in the Protocol. As part of that assessment process, household refrigeration was investigated to determine the status of CFC-12 replacements. The conclusion was that much progress has been made towards finding a suitable replacement. Compressors designed for HFC-134a have efficiencies comparable to those for CFC-12 and acceptable reliability tests have been obtained with ester lubricants. In addition, other replacements such as R-152a and refrigerant mixtures exist, but will require more study. Cycle options, such as the Stirling cycle, may be viable, but are further out in the future. The impact of new refrigerants is expected to result in elimination of CFC-12 consumption in developed countries by 1997 and in developing countries by 2005.

Vineyard, E.A. [Oak Ridge National Lab., TN (United States); Roke, L. [Fisher and Paykel, Auckland (New Zealand); Hallett, F. [Frigidaire, Washington, DC (United States)

1991-12-31T23:59:59.000Z

297

Factors Affecting Oxyfuel Gas Cutting  

Science Conference Proceedings (OSTI)

...of cutting quality and of economy in oxygen consumption. In metal thicknesses up to 50 or 75 mm (2 or 3

298

Carbon Dioxide and Ionic Liquid Refrigerants: Compact, Efficient Air Conditioning with Ionic Liquid-Based Refrigerants  

SciTech Connect

BEETIT Project: Notre Dame is developing an air-conditioning system with a new ionic liquid and CO2 as the working fluid. Synthetic refrigerants used in air conditioning and refrigeration systems are potent GHGs and can trap 1,000 times more heat in the atmosphere than CO2 alonemaking CO2 an attractive alternative for synthetic refrigerants in cooling systems. However, operating cooling systems with pure CO2 requires prohibitively high pressures and expensive hardware. Notre Dame is creating a new fluid made of CO2 and ionic liquid that enables the use of CO2 at low pressures and requires minimal changes to existing hardware and production lines. This new fluid also produces no harmful emissions and can improve the efficiency of air conditioning systems enabling new use of CO2 as a refrigerant in cooling systems.

2010-10-01T23:59:59.000Z

299

Floating Loop System For Cooling Integrated Motors And Inverters Using Hot Liquid Refrigerant  

DOE Patents (OSTI)

A floating loop vehicle component cooling and air-conditioning system having at least one compressor for compressing cool vapor refrigerant into hot vapor refrigerant; at least one condenser for condensing the hot vapor refrigerant into hot liquid refrigerant by exchanging heat with outdoor air; at least one floating loop component cooling device for evaporating the hot liquid refrigerant into hot vapor refrigerant; at least one expansion device for expanding the hot liquid refrigerant into cool liquid refrigerant; at least one air conditioning evaporator for evaporating the cool liquid refrigerant into cool vapor refrigerant by exchanging heat with indoor air; and piping for interconnecting components of the cooling and air conditioning system.

Hsu, John S [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN; Coomer, Chester [Knoxville, TN; Marlino, Laura D [Oak Ridge, TN

2006-02-07T23:59:59.000Z

300

The smallest refrigerators can reach maximal efficiency  

E-Print Network (OSTI)

We investigate whether size imposes a fundamental constraint on the efficiency of small thermal machines. We analyse in detail a model of a small self-contained refrigerator consisting of three qubits. We show analytically that this system can reach the Carnot efficiency, thus demonstrating that there exists no complementarity between size and efficiency.

Paul Skrzypczyk; Nicolas Brunner; Noah Linden; Sandu Popescu

2010-09-04T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Refrigeration in a world without CFCs  

Science Conference Proceedings (OSTI)

In an era of heightened awareness of energy efficiency and the associated environmental impacts, many industries, worldwide, are exploring ``environmentally friendly`` technologies that provide equivalent or improved performance while reducing or eliminating harmful side effects. The refrigeration and air conditioning industry, due to its reliance on CFCs and HCFCs has invested in research in alternatives to the industry standard vapor compression machines. One alternative technology with great promise is chemical absorption. Absorption chillers offer comparable refrigeration output with reduced SO{sub 2}, CO{sub 2}, and NO{sub x} emissions. Additionally, absorption chillers do not use CFCs or HCFCs, refrigerants that contribute to ozone depletion and global warming. The purpose of this paper is to provide an introduction for those new to absorption technology as well as a discussion of selected high efficiency cycles and environmental impacts for those familiar with absorption. The introduction will include a brief history of absorption and a description of the basic refrigeration cycle, while the advanced sections will discuss triple-effect technology and a life-cycle or ``systems`` approach to evaluating global warming impacts.

Garland, R.W. [U.S. Dept. of Energy, Washington D.C. (United States); Adcock, P.W. [Oak Ridge National Lab., TN (United States)

1996-09-01T23:59:59.000Z

302

Waste Heat Recapture from Supermarket Refrigeration Systems  

DOE Green Energy (OSTI)

The objective of this project was to determine the potential energy savings associated with improved utilization of waste heat from supermarket refrigeration systems. Existing and advanced strategies for waste heat recovery in supermarkets were analyzed, including options from advanced sources such as combined heat and power (CHP), micro-turbines and fuel cells.

Fricke, Brian A [ORNL

2011-11-01T23:59:59.000Z

303

International Refrigeration: Proposed Penalty (2012-CE-1510) | Department  

NLE Websites -- All DOE Office Websites (Extended Search)

International Refrigeration: Proposed Penalty (2012-CE-1510) International Refrigeration: Proposed Penalty (2012-CE-1510) International Refrigeration: Proposed Penalty (2012-CE-1510) July 9, 2012 DOE alleged in a Notice of Proposed Civil Penalty that International Refrigeration Products failed to certify a various room air conditioners as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. International Refrigeration: Proposed Penalty (2012-CE-1510) More Documents & Publications

304

Floating Refrigerant Loop Based on R-134a Refrigerant Cooling of High-Heat Flux Electronics  

SciTech Connect

The Oak Ridge National Laboratory (ORNL) Power Electronics and Electric Machinery Research Center (PEEMRC) have been developing technologies to address the thermal issues associated with hybrid vehicles. Removal of the heat generated from electrical losses in traction motors and their associated power electronics is essential for the reliable operation of motors and power electronics. As part of a larger thermal control project, which includes shrinking inverter size and direct cooling of electronics, ORNL has developed U.S. Patent No. 6,772,603 B2, ''Methods and Apparatus for Thermal Management of Vehicle Systems and Components'' [1], and patent pending, ''Floating Loop System for Cooling Integrated Motors and Inverters Using Hot Liquid Refrigerant'' [2]. The floating-loop system provides a large coefficient of performance (COP) for hybrid-drive component cooling. This loop (based on R-134a) is integrated with a vehicle's existing air-conditioning (AC) condenser, which dissipates waste heat to the ambient air. Because the temperature requirements for cooling of power electronics and electric machines are not as low as that required for passenger compartment air, this adjoining loop can operate on the high-pressure side of the existing AC system. This arrangement also allows the floating loop to run without the need for the compressor and only needs a small pump to move the liquid refrigerant. For the design to be viable, the loop must not adversely affect the existing system. The loop should also provide a high COP, a flat-temperature profile, and low-pressure drop. To date, the floating-loop test prototype has successfully removed 2 kW of heat load in a 9 kW automobile passenger AC system with and without the automotive AC system running. The COP for the tested floating-loop system ranges from 40-45, as compared to a typical AC system COP of about 2-4. The estimated required waste-heat load for future hybrid applications is 5.5 kW and the existing system could be easily scaleable for this larger load.

Lowe, K.T.

2005-10-07T23:59:59.000Z

305

Floating Refrigerant Loop Based on R-134a Refrigerant Cooling of High-Heat Flux Electronics  

SciTech Connect

The Oak Ridge National Laboratory (ORNL) Power Electronics and Electric Machinery Research Center (PEEMRC) have been developing technologies to address the thermal issues associated with hybrid vehicles. Removal of the heat generated from electrical losses in traction motors and their associated power electronics is essential for the reliable operation of motors and power electronics. As part of a larger thermal control project, which includes shrinking inverter size and direct cooling of electronics, ORNL has developed U.S. Patent No. 6,772,603 B2, ''Methods and Apparatus for Thermal Management of Vehicle Systems and Components'' [1], and patent pending, ''Floating Loop System for Cooling Integrated Motors and Inverters Using Hot Liquid Refrigerant'' [2]. The floating-loop system provides a large coefficient of performance (COP) for hybrid-drive component cooling. This loop (based on R-134a) is integrated with a vehicle's existing air-conditioning (AC) condenser, which dissipates waste heat to the ambient air. Because the temperature requirements for cooling of power electronics and electric machines are not as low as that required for passenger compartment air, this adjoining loop can operate on the high-pressure side of the existing AC system. This arrangement also allows the floating loop to run without the need for the compressor and only needs a small pump to move the liquid refrigerant. For the design to be viable, the loop must not adversely affect the existing system. The loop should also provide a high COP, a flat-temperature profile, and low-pressure drop. To date, the floating-loop test prototype has successfully removed 2 kW of heat load in a 9 kW automobile passenger AC system with and without the automotive AC system running. The COP for the tested floating-loop system ranges from 40-45, as compared to a typical AC system COP of about 2-4. The estimated required waste-heat load for future hybrid applications is 5.5 kW and the existing system could be easily scaleable for this larger load.

Lowe, K.T.

2005-10-07T23:59:59.000Z

306

Geothermal absorption refrigeration for food processing industries. Final report, December 13, 1976--November 13, 1977  

DOE Green Energy (OSTI)

The first step in the economic analysis of the integration of geothermally powered absorption refrigeration into a food processing plant was an evaluation of the potential geothermal sites in the Western United States. The evaluation covered availability of raw materials, transportation, adequate geothermal source, labor, and other requirements for food processing plants. Several attractive geothermal sites were identified--Raft River, Idaho; Sespe Hot Springs, California; Vale Hot Springs, Oregon; Weisler-Crane Creek, Idaho; Cosco Hot Springs, California; and the Imperial Valley, California. The most economically attractive food processing industry was then matched to the site based on its particular energy, raw material, and transportation requirements. The more promising food processors identified were for frozen potato or vegetable products, freeze-dried products, and meat processing. For the refrigeration temperature range of +32/sup 0/F to -40/sup 0/F and geothermal temperature range of 212/sup 0/F to 300/sup 0/F, an absorption refrigeration system had to be identified, designed, and evaluated. Both the conventional ammonia/water and an organic absorption refrigeration system using monochlorodifluoromethane (R-22) as the refrigerant and dimethyl formamide (DMF) as the absorbent were studied. In general, only a 60/sup 0/F to 100/sup 0/F temperature drop would be effectively used for refrigeration leaving the remainder of the allowable temperature drop available for other use. The economic evaluation of the geothermal system installed in a food processing plant required the comparison of several principal alternatives. These alternatives were evaluated for three different food processing plants located at their optimum geothermal site: a forzen potato product processing plant located at Raft River, Idaho; a freeze-dried product plant located at Sespe Hot Springs, California; a beef slaughter operation located in the Imperial Valley of California. (JGB)

Harris, R.L.; Olson, G.K.; Mah, C.S.; Bujalski, J.H.

1977-11-01T23:59:59.000Z

307

Scaling and Optimization of Magnetic Refrigeration for Commercial Building HVAC Systems Greater than 175 kW in Capacity  

Science Conference Proceedings (OSTI)

Heating, ventilation, air-conditioning and refrigeration (HVACR) account for approximately one- third of building energy consumption. Magnetic refrigeration presents an opportunity for significant energy savings and emissions reduction for serving the building heating, cooling, and refrigeration loads. In this paper, we have examined the magnet and MCE material requirements for scaling magnetic refrigeration systems for commercial building cooling applications. Scaling relationships governing the resources required for magnetic refrigeration systems have been developed. As system refrigeration capacity increases, the use of superconducting magnet systems becomes more applicable, and a comparison is presented of system requirements for permanent and superconducting (SC) magnetization systems. Included in this analysis is an investigation of the ability of superconducting magnet based systems to overcome the parasitic power penalty of the cryocooler used to keep SC windings at cryogenic temperatures. Scaling relationships were used to develop the initial specification for a SC magnet-based active magnetic regeneration (AMR) system. An optimized superconducting magnet was designed to support this system. In this analysis, we show that the SC magnet system consisting of two 0.38 m3 regenerators is capable of producing 285 kW of cooling power with a T of 28 K. A system COP of 4.02 including cryocooler and fan losses which illustrates that an SC magnet-based system can operate with efficiency comparable to traditional systems and deliver large cooling powers of 285.4 kW (81.2 Tons).

Abdelaziz, Omar [ORNL; West, David L [ORNL; Mallow, Anne M [ORNL

2012-01-01T23:59:59.000Z

308

Building Technologies Office: Low-Global Warming Potential Refrigerants  

NLE Websites -- All DOE Office Websites (Extended Search)

Low-Global Warming Low-Global Warming Potential Refrigerants Research Project to someone by E-mail Share Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Facebook Tweet about Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Twitter Bookmark Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Google Bookmark Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Delicious Rank Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on Digg Find More places to share Building Technologies Office: Low-Global Warming Potential Refrigerants Research Project on AddThis.com... About Take Action to Save Energy

309

Dilution cycle control for an absorption refrigeration system  

DOE Patents (OSTI)

A dilution cycle control system for an absorption refrigeration system is disclosed. The control system includes a time delay relay for sensing shutdown of the absorption refrigeration system and for generating a control signal only after expiration of a preselected time period measured from the sensed shutdown of the absorption refrigeration system, during which the absorption refrigeration system is not restarted. A dilution cycle for the absorption refrigeration system is initiated in response to generation of a control signal by the time delay relay. This control system is particularly suitable for use with an absorption refrigeration system which is frequently cycled on and off since the time delay provided by the control system prevents needless dilution of the absorption refrigeration system when the system is turned off for only a short period of time and then is turned back on.

Reimann, Robert C. (Lafayette, NY)

1984-01-01T23:59:59.000Z

310

CRAD, Welding, Cutting and Brazing Assessment Plan | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Welding, Cutting and Brazing Assessment Plan Welding, Cutting and Brazing Assessment Plan CRAD, Welding, Cutting and Brazing Assessment Plan Performance Objective: This assessment is to verify hot work requirements associated with welding, cutting, burning, brazing, grinding and other spark- or flame-producing operations have been implemented. Verify that the requirements implemented are appropriate for preventing loss of life and property from fire, and personal injury from contact with or exposure to molten metals, vapors, radiant energy, injurious rays and sparks. Criteria: Establish designated area in which routine and repetitive welding, cutting, and other spark- or flame producing operations are conducted [1910.252(a)(2)(iv),1910.252(a)(2)(vi)(A), 1910.252(a)(2)(xv), General Requirements].

311

ADVANCED UNDERGROUND GAS STORAGE CONCEPTS REFRIGERATED-MINED CAVERN STORAGE  

Science Conference Proceedings (OSTI)

Limited demand and high cost has prevented the construction of hard rock caverns in this country for a number of years. The storage of natural gas in mined caverns may prove technically feasible if the geology of the targeted market area is suitable; and economically feasible if the cost and convenience of service is competitive with alternative available storage methods for peak supply requirements. It is believed that mined cavern storage can provide the advantages of high delivery rates and multiple fill-withdrawal cycles in areas where salt cavern storage is not possible. In this research project, PB-KBB merged advanced mining technologies and gas refrigeration techniques to develop conceptual designs and cost estimates to demonstrate the commercialization potential of the storage of refrigerated natural gas in hard rock caverns. Five regions of the U.S.A. were studied for underground storage development and PB-KBB reviewed the literature to determine if the geology of these regions was suitable for siting hard rock storage caverns. Area gas market conditions in these regions were also studied to determine the need for such storage. Based on an analysis of many factors, a possible site was determined to be in Howard and Montgomery Counties, Maryland. The area has compatible geology and a gas industry infrastructure for the nearby market populous of Baltimore and Washington D.C.. As Gas temperature is lowered, the compressibility of the gas reaches an optimum value. The compressibility of the gas, and the resultant gas density, is a function of temperature and pressure. This relationship can be used to commercial advantage by reducing the size of a storage cavern for a given working volume of natural gas. This study looks at this relationship and and the potential for commercialization of the process in a storage application. A conceptual process design, and cavern design were developed for various operating conditions. Potential site locations were considered and a typical plant layout was developed. In addition a geomechanical review of the proposed cavern design was performed, evaluating the stability of the mine rooms and shafts, and the effects of the refrigerated gas temperatures on the stability of the cavern. Capital and operating cost estimates were also developed for the various temperature cases considered. The cost estimates developed were used to perform a comparative market analysis of this type of gas storage system to other systems that are commercially used in the region of the study.

NONE

1998-09-01T23:59:59.000Z

312

Cutting forces in orthogonal cutting of unidirectional GFRP composites  

SciTech Connect

The results of orthogonal cutting tests carried out on unidirectional glass fiber reinforced plastic composites, using HSS tools, are presented and discussed. During the tests, performed on a milling machine at very low cutting speed to avoid thermal effects, the cutting speed was held constant and parallel to the fiber direction. Three parameters, namely the tool rake angle {alpha}, the tool relief angle {gamma}, and the depth of cut t, were varied. According to the experimental results, the horizontal force per unit width, F{sub hu}, undergoes a dramatic decrease, never verified for metals, with increasing {alpha}. Besides, F{sub hu} is only negligibly affected by the relief angle, and linearly increases with t. Similarly to metals, an effect of the depth of cut on the specific energy (size effect) is found also for composites. However, the presented results indicate that the size effect can be analytically modeled in a simple way in the case of composites. The vertical force per unit width, F{sub vu}, exhibits a marked reduction when the relief angle is increased. F{sub vu} is also very sensitive to the rake angle: the lower {alpha}, the higher is F{sub vu}. It is shown that this behavior probably reflects a strong influence of the rake angle on the forces developing at the flank. A linear dependence of the vertical force on the depth of cut is also demonstrated. Finally, the experimental data are utilized to obtain empirical formulae, allowing an approximate evaluation of cutting forces.

Caprino, G.; Nele, L. [Univ. of Naples Federico II (Italy). Dept. of Materials and Production Engineering

1996-07-01T23:59:59.000Z

313

Membrane-Based Absorption Refrigeration Systems: Nanoengineered Membrane-Based Absorption Cooling for Buildings Using Unconcentrated Solar & Waste Heat  

Science Conference Proceedings (OSTI)

BEETIT Project: UFL is improving a refrigeration system that uses low quality heat to provide the energy needed to drive cooling. This system, known as absorption refrigeration system (ARS), typically consists of large coils that transfer heat. Unfortunately, these large heat exchanger coils are responsible for bulkiness and high cost of ARS. UFL is using new materials as well as system design innovations to develop nanoengineered membranes to allow for enhanced heat exchange that reduces bulkiness. UFLs design allows for compact, cheaper and more reliable use of ARS that use solar or waste heat.

None

2010-09-01T23:59:59.000Z

314

International Refrigeration: Order (2012-CE-1510)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

WASHINGTON, D.C. 20585 WASHINGTON, D.C. 20585 Case Number: 2012-CE-1510 International Refrigeration Products, Respondent ) ) ) ) ) ) ORDER Issued: July 20, 2012 By the General Counsel, U.S. Department of Energy: 1. In this Order, I adopt the attached Compromise Agreement entered into between the U.S. Department of Energy ("DOE") and International Refrigeration Products ("Respondent"). The Compromise Agreement resolves the case initiated to pursue a civil penalty for violations of the compliance certification requirements located at 10 C.P.R. § 429.12. 2. DOE and Respondent have negotiated the terms of the Compromise Agreement that resolve this matter. A copy of the Compromise Agreement is attached hereto and incorporated by reference. 3. After reviewing the terms of the Compromise Agreement and evaluating the facts

315

Selection of a Cutting Fluid  

Science Conference Proceedings (OSTI)

...Tapping Threading Gear cutting Deep hole drilling Boring Screw machining with form tools High-speed, light-feed screw machining Reaming Milling Drilling Planing and shaping Turning, single-point tools Sawing Grinding...

316

Could You Save Money on Your Refrigerator? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? July 20, 2012 - 4:35pm Addthis Earlier this week, Amanda wrote about how you can save energy by choosing the right refrigerator and using it efficiently. These tips explain all sorts of ways you can ensure your refrigerator uses as little energy as possible to keep itself cool. So this week, we're curious: Could you save money with your refrigerator? You have the chance to share your thoughts on a question about energy efficiency or renewable energy for consumers. E-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov. Addthis Related Articles How Do You Save Money on Summer Holidays? Have You Seen Energy Efficiency Improvements in Your Neighborhood?

317

Could You Save Money on Your Refrigerator? | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? Could You Save Money on Your Refrigerator? July 20, 2012 - 4:35pm Addthis Earlier this week, Amanda wrote about how you can save energy by choosing the right refrigerator and using it efficiently. These tips explain all sorts of ways you can ensure your refrigerator uses as little energy as possible to keep itself cool. So this week, we're curious: Could you save money with your refrigerator? You have the chance to share your thoughts on a question about energy efficiency or renewable energy for consumers. E-mail your responses to the Energy Saver team at consumer.webmaster@nrel.gov. Addthis Related Articles How Do You Save Money on Summer Holidays? Have You Seen Energy Efficiency Improvements in Your Neighborhood?

318

Method of reducing chlorofluorocarbon refrigerant emissons to the atmosphere  

DOE Patents (OSTI)

A method is disclosed for reducing chloroflurocarbon (CFC) refrigerant emissions during removal or transfer or refrigerants from a vapor compression cooling system or heat pump which comprises contacting the refrigerant with a suitable sorbent material. The sorbent material allows for the storage and retention or the chlorofluorocarbon in non-gaseous form so that it does not tend to escape to the atmosphere where it would cause harm by contributing to ozone depletion. In other aspects of the invention, contacting of CFC refrigerants with sorbent material allows for purification and recycling of used refrigerant, and a device containing stored sorbent material can be employed in the detection of refrigerant leakage in a cooling system or heat pump.

DeVault, Robert C. (Knoxville, TN); Fairchild, Phillip D. (Clinton, TN); Biermann, Wendell J. (Fayetteville, NY)

1990-01-01T23:59:59.000Z

319

Microwave assisted hard rock cutting  

DOE Patents (OSTI)

An apparatus for the sequential fracturing and cutting of subsurface volume of hard rock (102) in the strata (101) of a mining environment (100) by subjecting the volume of rock to a beam (25) of microwave energy to fracture the subsurface volume of rock by differential expansion; and , then bringing the cutting edge (52) of a piece of conventional mining machinery (50) into contact with the fractured rock (102).

Lindroth, David P. (Apple Valley, MN); Morrell, Roger J. (Bloomington, MN); Blair, James R. (Inver Grove Heights, MN)

1991-01-01T23:59:59.000Z

320

Active magnetic refrigerants based on Gd-Si-Ge material and refrigeration apparatus and process  

DOE Patents (OSTI)

Active magnetic regenerator and method using Gd.sub.5 (Si.sub.x Ge.sub.1-x).sub.4, where x is equal to or less than 0.5, as a magnetic refrigerant that exhibits a reversible ferromagnetic/antiferromagnetic or ferromagnetic-II/ferromagnetic-I first order phase transition and extraordinary magneto-thermal properties, such as a giant magnetocaloric effect, that renders the refrigerant more efficient and useful than existing magnetic refrigerants for commercialization of magnetic regenerators. The reversible first order phase transition is tunable from approximately 30 K to approximately 290 K (near room temperature) and above by compositional adjustments. The active magnetic regenerator and method can function for refrigerating, air conditioning, and liquefying low temperature cryogens with significantly improved efficiency and operating temperature range from approximately 10 K to 300 K and above. Also an active magnetic regenerator and method using Gd.sub.5 (Si.sub.x Ge.sub.1-x).sub.4, where x is equal to or greater than 0.5, as a magnetic heater/refrigerant that exhibits a reversible ferromagnetic/paramagnetic second order phase transition with large magneto-thermal properties, such as a large magnetocaloric effect that permits the commercialization of a magnetic heat pump and/or refrigerant. This second order phase transition is tunable from approximately 280 K (near room temperature) to approximately 350 K by composition adjustments. The active magnetic regenerator and method can function for low level heating for climate control for buildings, homes and automobile, and chemical processing.

Gschneidner, Jr., Karl A. (Ames, IA); Pecharsky, Vitalij K. (Ames, IA)

1998-04-28T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Active magnetic refrigerants based on Gd-Si-Ge material and refrigeration apparatus and process  

DOE Patents (OSTI)

Active magnetic regenerator and method using Gd{sub 5} (Si{sub x}Ge{sub 1{minus}x}){sub 4}, where x is equal to or less than 0.5, as a magnetic refrigerant that exhibits a reversible ferromagnetic/antiferromagnetic or ferromagnetic-II/ferromagnetic-I first order phase transition and extraordinary magneto-thermal properties, such as a giant magnetocaloric effect, that renders the refrigerant more efficient and useful than existing magnetic refrigerants for commercialization of magnetic regenerators. The reversible first order phase transition is tunable from approximately 30 K to approximately 290 K (near room temperature) and above by compositional adjustments. The active magnetic regenerator and method can function for refrigerating, air conditioning, and liquefying low temperature cryogens with significantly improved efficiency and operating temperature range from approximately 10 K to 300 K and above. Also an active magnetic regenerator and method using Gd{sub 5} (Si{sub x} Ge{sub 1{minus}x}){sub 4}, where x is equal to or greater than 0.5, as a magnetic heater/refrigerant that exhibits a reversible ferromagnetic/paramagnetic second order phase transition with large magneto-thermal properties, such as a large magnetocaloric effect that permits the commercialization of a magnetic heat pump and/or refrigerant. This second order phase transition is tunable from approximately 280 K (near room temperature) to approximately 350 K by composition adjustments. The active magnetic regenerator and method can function for low level heating for climate control for buildings, homes and automobile, and chemical processing. 27 figs.

Gschneidner, K.A. Jr.; Pecharsky, V.K.

1998-04-28T23:59:59.000Z

322

Energy conservation for household refrigerators and water heaters  

Science Conference Proceedings (OSTI)

An energy conservation arrangement for household refrigerators and water heaters, in which the source of cold water to the hot water heater is divided and part is caused to flow through and be warmed in the condenser of the refrigerator. The warmed water is then further heated in the oil cooling loop of the refrigerator compressor, and proceeds then to the top of the hot water tank.

Speicher, T. L.

1984-12-11T23:59:59.000Z

323

Implementing cutting plane management and selection techniques  

E-Print Network (OSTI)

Closely related to cut generation is the problem of reducing the number of ... They concentrate on generating cuts which ...... Programming, pages 124, 2012. 5.

324

Shroud for a submerged jet cutting nozzle  

DOE Patents (OSTI)

A shroud for a submerged jet cutting nozzle is described which separates the jet from surrounding fluid environment and enhances the cutting effect.

Schwab, Thomas L. (1369 Windsor Way, Livermore, CA 94550)

1978-01-01T23:59:59.000Z

325

List of Commercial Refrigeration Equipment Incentives | Open Energy  

Open Energy Info (EERE)

Refrigeration Equipment Incentives Refrigeration Equipment Incentives Jump to: navigation, search The following contains the list of 103 Commercial Refrigeration Equipment Incentives. CSV (rows 1 - 103) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP Appalachian Power - Commercial and Industrial Rebate Programs (West Virginia) Utility Rebate Program West Virginia Commercial Industrial Central Air conditioners Chillers Custom/Others pending approval Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Programmable Thermostats Commercial Refrigeration Equipment Ground Source Heat Pumps Yes AEP Ohio - Commercial New Construction Energy Efficiency Rebate Program (Ohio) Utility Rebate Program Ohio Commercial Industrial Local Government Municipal Utility

326

Geothermal: Sponsored by OSTI -- Chapter 13. Absorption Refrigeration  

Office of Scientific and Technical Information (OSTI)

GEOTHERMAL TECHNOLOGIES LEGACY COLLECTION - Sponsored by OSTI -- Chapter 13. Absorption Refrigeration Geothermal Technologies Legacy Collection HelpFAQ | Site Map | Contact Us |...

327

Economizer refrigeration cycle space heating and cooling system and process  

DOE Patents (OSTI)

This invention relates to heating and cooling systems and more particularly to an improved system utilizing a Stirling Cycle engine heat pump in a refrigeration cycle. 18 figs.

Jardine, D.M.

1983-03-22T23:59:59.000Z

328

Thermal Analysis of Refrigeration Systems Used for Vaccine ...  

Science Conference Proceedings (OSTI)

... may result from planned HVAC outages at night or ... recording data after the refrigerator was powered. ... the length of the power outage and the ...

2012-08-02T23:59:59.000Z

329

Electric, Gas, Water, Heating, Refrigeration, and Street Railways...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

and Street Railways Facilities and Service (South Dakota) Electric, Gas, Water, Heating, Refrigeration, and Street Railways Facilities and Service (South Dakota) < Back...

330

The Ghana Refrigerator Efficiency Initiative - An Overview of...  

NLE Websites -- All DOE Office Websites (Extended Search)

refrigeration services the most expensive of energy services in residential Ghanaian households, posing serious financial burden on households. --The problem that this project...

331

Purchase of newer refrigerators slows during economic downturn ...  

U.S. Energy Information Administration (EIA)

Sales data from the Association of Home Appliance ... Decreasing sales of new refrigerators means slower adoption of new energy-efficient technology and less ...

332

Energy Efficiency Standards for Refrigerators in Brazil: A Methodology...  

Open Energy Info (EERE)

It uses a bottom-up approach to estimate residential end-use consumption and evaluate the energy saving potential for refrigerators. References Retrieved from "http:...

333

Federal Energy Management Program: New and Underutilized Refrigeration...  

NLE Websites -- All DOE Office Websites (Extended Search)

Power Management, and Vending Machine Technologies to someone by E-mail Share Federal Energy Management Program: New and Underutilized Refrigeration, Computer Power Management,...

334

Economizer refrigeration cycle space heating and cooling system and process  

DOE Patents (OSTI)

This invention relates to heating and cooling systems and more particularly to an improved system utilizing a Stirling Cycle engine heat pump in a refrigeration cycle.

Jardine, Douglas M. (Colorado Springs, CO)

1983-01-01T23:59:59.000Z

335

DOE Opens Three Investigations into Alleged Refrigerator Efficiency...  

NLE Websites -- All DOE Office Websites (Extended Search)

The Department of Energy has issued one subpoena and two data requests to three companies in response to allegations that the companies are selling refrigerator-freezers that...

336

Analysis of Mass Flow and Enhanced Mass Flow Methods of Flashing Refrigerant-22 from a Small Vessel  

E-Print Network (OSTI)

The mass flow characteristics of flashing Refrigerant-22 from a small vessel were investigated. A flash boiling apparatus was designed and built. It was modeled after the flashing process encountered by the accumulator of air-source heat pump systems. Three small pyrex glass vessels were used to hold the refrigerant and allow for visualization studies of the flashing process. Baseline experiments were run varying initial pressure, initial refrigerant amount, orifice diameter, and vessel geometry. Three sets of experiments were run using two passive enhancement methods (the addition of steel balls and the addition of small amounts of oil) and one active enhancement method (the addition of an immersion heater). Furthermore, a lumped-parameter analytical model was developed from basic thermodynamic principles that predicted the rate of depressurization for the flashing refrigerant. The study showed that the initial refrigerant amount and the orifice size had the greatest influence on the mass flow and pressure characteristics during each sixty second test. The initial pressure and vessel volume had less of an impact under the conditions tested. Two of the enhancement methods consistently increased the amount of refrigerant flashed during the tests as compared to the baseline data for the same initial conditions. The addition a 1 cm layer of 3.6 mm steel balls to the base of the vessel increased the amount flashed from 21% to 81% and the addition of the 215-watt flat-spiral immersion heater the increased the amount flashed from 47% to 111 %. Foaming at the vapor-liquid interface was observed with the refrigerant-oil mixture experiments as two of the eight test conditions averaged an increase while six averaged a decrease, ranging from a 21% increase to a 27% decrease. The analytical depressurization model predicted general pressure and mass flux trends, and revisions to the model improved pressure predictions to within 11%.

Nutter, Darin Wayne

1994-12-01T23:59:59.000Z

337

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

338

Properties and Cycle Performance of Refrigerant Blends Operating Near and Above the Refrigerant Critical Point, Task 2: Air Conditioner System Study  

SciTech Connect

The main goal of this project was to investigate and compare the performance of an R410A air conditioner to that of an R22 air conditioner, with specific interest in performance at high ambient temperatures at which the condenser of the R410A system may be operating above the refrigerant's critical point. Part 1 of this project consisted of conducting comprehensive measurements of thermophysical for refrigerant R125 and refrigerant blends R410A and R507A and developing new equation of state formulations and mixture models for predicting thermophysical properties of HFC refrigerant blends. Part 2 of this project conducted performance measurements of split-system, 3-ton R22 and R410A residential air conditioners in the 80 to 135 F (27.8 to 57.2 C) outdoor temperature range and development of a system performance model. The performance data was used in preparing a beta version of EVAP-COND, a windows-based simulation package for predicting performance of finned-tube evaporators and condensers. The modeling portion of this project also included the formulation of a model for an air-conditioner equipped with a thermal expansion valve (TXV). Capacity and energy efficiency ratio (EER) were measured and compared. The R22 system's performance was measured over the outdoor ambient temperature range of 80 to 135 F (27.8 to 57.2 C). The same test range was planned for the R410A system. However, the compressor's safety system cut off the compressor at the 135.0 F (57.2 C) test temperature. The highest measurement on this system was at 130.0 F (54.4 C). Subsequently, a custom-manufactured R410A compressor with a disabled safety system and a more powerful motor was installed and performance was measured at outdoor temperatures up to 155.0 F (68.3 C). Both systems had similar capacity and EER performance at 82.0 F (27.8 C). The capacity and EER degradation of both systems were nearly linearly dependent with rising ambient outdoor ambient test temperatures. The performance degradation of R410A at higher temperatures was greater than R22. However, the R22 and R410A systems both operated normally during all tests. Visual observations of the R410A system provided no indication of vibrations or TXV hunting at high ambient outdoor test conditions with the compressor operating in the transcritical regime.

Piotr A. Domanski; W. Vance Payne

2002-10-31T23:59:59.000Z

339

A continuous heat regenerative adsorption refrigerator using spiral plate heat exchanger as adsorbers: improvements  

SciTech Connect

Spiral plate heat exchangers as adsorbers have been proposed, and a prototype heat regenerative adsorption refrigerator using activated carbon-methanol pair has been developed and tested. Various improvements have been made, the authors get a specific cooling power for 2.6 kg-ice/day-kg adsorbent at the condition of generation temperature lower than 100 C. Discussions on the arrangements of thermal cycles and influences of design are shown.

Wang, R.Z.; Wu, J.Y.; Xu, Y.X. [Shanghai Jiao Tong Univ. (China). Inst. of Refrigeration and Cryogenics

1999-02-01T23:59:59.000Z

340

Cut Your Power Bills  

E-Print Network (OSTI)

Electric power bills can often be reduced by careful attention to the inter-relationship between your plant operations and the electric rate schedule on which your bill is based. The pattern of use of electricity by your plant over a given time span is called its load profile. A continuous process operating 365 days a year would have a flat profile whether measured on a daily, weekly, monthly or yearly basis. But most plant profiles ere not flat because operations may not be consistent for three shifts a day, seven days a week, all year. Profile characteristics of interest to your utility are maximum demand, load factor, time of demand peaks and valleys and power factor. After discussing each of these characteristics below, we will discuss how electric rate schedules are designed, how they are analyzed, and where you can look for possible savings.

Greenwood, R. W.

1979-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Commissioning and Operational Experience with 1 kW Class Helium Refrigerator/Liquefier for SST?1  

Science Conference Proceedings (OSTI)

The helium refrigerator/liquefier (R/L) for the Steady State Super conducting Tokamak (SST?1) has been developed with very stringent specifications for the different operational modes. The total refrigeration capacity is 650 W at 4.5 K and liquefaction capacity of 200 l/h. A cold circulation pump is used for the forced flow cooling of 300 g/s supercritical helium (SHe) for the magnet system (SCMS). The R/L has been designed also to absorb a 200 W transient heat load of the SCMS. The plant consists of a compressor station

C. P. Dhard; B. Sarkar; Ruchi Misra; A. K. Sahu; V. L. Tanna; J. Tank; P. Panchal; J. C. Patel; G. D. Phadke; Y. C. Saxena

2004-01-01T23:59:59.000Z

342

U.S. Residential Miscellaneous Refrigeration Products: Results from Amazon Mechanical Turk Surveys  

E-Print Network (OSTI)

icemakers and non-vapor compression refrigerators and2.5,+4.5) million non-vapor compression refrigerators inthe existence of non-vapor compression freezers. Moreover,

Greenblatt, Jeffery B.

2013-01-01T23:59:59.000Z

343

Refrigeration system with a compressor-pump unit and a liquid ...  

The refrigeration system includes a compressor-pump unit and/or a liquid-injection assembly. The refrigeration system is a vapor-compression refrigera ...

344

Verification of a level-3 diesel emissions control strategy for transport refrigeration units.  

E-Print Network (OSTI)

??Transport Refrigeration Units (TRUs) are refrigeration systems used to control the environment of temperature sensitive products while they are being transported from one place to (more)

Shewalla, Umesh.

2010-01-01T23:59:59.000Z

345

Magnetic refrigeration apparatus with heat pipes  

DOE Patents (OSTI)

A magnetic refrigerator operating in the 4 to 20 K range utilizes heat pipes to transfer heat to and from the magnetic material at the appropriate points during the material's movement. In one embodiment circular disks of magnetic material can be interleaved with the ends of the heat pipes. In another embodiment a mass of magnetic material reciprocatingly moves between the end of the heat pipe or pipes that transmits heat from the object of cooling to the magnetic material and the end of the heat pipe or pipes that transmits heat from the magnetic material to a heat sink.

Barclay, J.A.; Prenger, F.C. Jr.

1985-10-25T23:59:59.000Z

346

Magnetic refrigeration apparatus with heat pipes  

DOE Patents (OSTI)

A magnetic refrigerator operating in the 4 to 20 K range utilizes heat pipes to transfer heat to and from the magnetic material at the appropriate points during the material's movement. In one embodiment circular disks of magnetic material can be interleaved with the ends of the heat pipes. In another embodiment a mass of magnetic material reciprocatingly moves between the end of the heat pipe of pipes that transmits heat from the object of cooling to the magnetic material and the end of the heat pipe or pipes that transmits heat from the magnetic material to a heat sink.

Barclay, John A. (Los Alamos, NM); Prenger, Jr., F. Coyne (Madison, WI)

1987-01-01T23:59:59.000Z

347

Solar absorption refrigeration system using new working fluid pairs  

Science Conference Proceedings (OSTI)

Absorption refrigeration systems powered by solar energy increasingly attract research interests in the last years. In this study, thermodynamic analyses for different working fluid pairs are performed. A computer simulation model has been developed ... Keywords: NH3-LiNO3, absorption, crystallization, generator, performance, refrigeration, solar energy

Jasim M. Abdulateef; Kamaruzzaman Sopian; M. A. Alghoul; Mohd Yusof Sulaiman; Azami Zaharim; Ibrahim Ahmad

2008-02-01T23:59:59.000Z

348

Performance monitoring strategies for effective running of commercial refrigeration systems  

Science Conference Proceedings (OSTI)

Refrigeration systems often represent the largest electricity consumers in the supermarkets. Therefore there is a clear need for running these systems effectively. Performance monitoring uses different techniques to determine the actual system state. ... Keywords: COP, FDD, energy monitoring, performance measure, refrigeration

Martin Hrn?r; Petr Stluka

2010-05-01T23:59:59.000Z

349

Energy efficiency strategies in refrigeration systems of large supermarkets  

Science Conference Proceedings (OSTI)

Energy efficiency and its relationship with sustainable development are one of the most important objectives in modern engineering systems. In Industrial Installations that use refrigeration systems that are associated with the food industry, this optimization ... Keywords: energy efficiency, optimizing parameters, refrigeration systems, supermarkets

J. M. Garcia; L. M. R. Coelho

2010-07-01T23:59:59.000Z

350

Description and validation of a computer based refrigeration system simulator  

Science Conference Proceedings (OSTI)

This paper describes and evaluates the validation of a novel software package which simulates the transient and steady-state operation of whole refrigeration systems of the type used for the storage and processing of food. This software allows practitioners ... Keywords: Computer simulation, Food processing, Modelling, Refrigeration

I. W. Eames; T. Brown; J. A. Evans; G. G. Maidment

2012-07-01T23:59:59.000Z

351

Lanthanide Al-Ni base Ericsson cycle magnetic refrigerants  

DOE Patents (OSTI)

A magnetic refrigerant for a magnetic refrigerator using the Ericsson thermodynamic cycle comprises DyAlNi and (Gd{sub 0.54}Er{sub 0.46})AlNi alloys having a relatively constant {Delta}Tmc over a wide temperature range. 16 figs.

Gschneidner, K.A. Jr.; Takeya, Hiroyuki

1995-10-31T23:59:59.000Z

352

New concepts for refrigerant leak detection and mixture measurement  

Science Conference Proceedings (OSTI)

Since the discovery that chlorofluorocarbons (CFCs) destroy the ozone layer, the need to reduce the release of these refrigerants into the environment has become critical. A total ban of ozone-depleting CFCs is expected within a few years, and hydrofluorocarbons (HFCs) and fluorocarbons (FCs) and their mixtures are expected to be used during a transition period. Several HFC and FC refrigerants are currently being considered as CFC substitutes. The electronic refrigerant leak detectors currently being considered as CFC substitutes. The electronic refrigerant leak detectors currently on the market were developed to detect CFCs and are not as sensitive to HFCs. Although incremental improvement can be made to these devices to detect HFCs, they often lead to increased false signals. Also, there is no simple device available to measure the composition of a refrigerant mixture. The authors present two new concepts to aid in the development of two portable instruments that can be used for HFC leak detection and for quantitative measurement of refrigerant mixture compositions. The development of simple, easy-to-use portable leak detectors and refrigerant mixture meters is essential to the wide use of alternative refrigerants in industry.

Chen, F.C.; Allman, S.L.; Chen, C.H.

1993-12-31T23:59:59.000Z

353

Lanthanide Al-Ni base Ericsson cycle magnetic refrigerants  

DOE Patents (OSTI)

A magnetic refrigerant for a magnetic refrigerator using the Ericsson thermodynamic cycle comprises DyAlNi and (Gd.sub.0.54 Er.sub.0.46)AlNi alloys having a relatively constant .DELTA.Tmc over a wide temperature range.

Gschneidner, Jr., Karl A. (Ames, IA); Takeya, Hiroyuki (Ibaraki, JP)

1995-10-31T23:59:59.000Z

354

Hypervelocity cutting machine and method  

DOE Patents (OSTI)

A method and machine are provided for cutting a workpiece such as concrete. A gun barrel is provided for repetitively loading projectiles therein and is supplied with a pressurized propellant from a storage tank. A thermal storage tank is disposed between the propellant storage tank and the gun barrel for repetitively receiving and heating propellant charges which are released in the gun barrel for repetitively firing projectiles therefrom toward the workpiece. In a preferred embodiment, hypervelocity of the projectiles is obtained for cutting the concrete workpiece by fracturing thereof. 10 figs.

Powell, J.R.; Reich, M.

1996-11-12T23:59:59.000Z

355

Hypervelocity cutting machine and method  

DOE Patents (OSTI)

A method and machine 14 are provided for cutting a workpiece 12 such as concrete. A gun barrel 16 is provided for repetitively loading projectiles 22 therein and is supplied with a pressurized propellant from a storage tank 28. A thermal storage tank 32,32A is disposed between the propellant storage tank 28 and the gun barrel 16 for repetitively receiving and heating propellant charges which are released in the gun barrel 16 for repetitively firing projectiles 22 therefrom toward the workpiece 12. In a preferred embodiment, hypervelocity of the projectiles 22 is obtained for cutting the concrete workpiece 12 by fracturing thereof.

Powell, James R. (Shoreham, NY); Reich, Morris (Queens, NY)

1996-11-12T23:59:59.000Z

356

Microbiopsy/precision cutting devices  

DOE Patents (OSTI)

Devices are disclosed for performing tissue biopsy on a small scale (microbiopsy). By reducing the size of the biopsy tool and removing only a small amount of tissue or other material in a minimally invasive manner, the risks, costs, injury and patient discomfort associated with traditional biopsy procedures can be reduced. By using micromachining and precision machining capabilities, it is possible to fabricate small biopsy/cutting devices from silicon. These devices can be used in one of four ways (1) intravascularly, (2) extravascularly, (3) by vessel puncture, and (4) externally. Additionally, the devices may be used in precision surgical cutting. 6 figs.

Krulevitch, P.A.; Lee, A.P.; Northrup, M.A.; Benett, W.J.

1999-07-27T23:59:59.000Z

357

Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Duracold Refrigeration Manufacturing: Proposed Penalty Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342) February 21, 2013 DOE alleged in a Notice of Proposed Civil Penalty that Duracold Refrigeration Manufacturing Company, LLC failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. Duracold Refrigeration Manufacturing: Proposed Penalty (2013-CE-5342)

358

DOE Closes Investigation of Whirlpool's Maytag Refrigerator | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Closes Investigation of Whirlpool's Maytag Refrigerator Closes Investigation of Whirlpool's Maytag Refrigerator DOE Closes Investigation of Whirlpool's Maytag Refrigerator July 8, 2010 - 3:12pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Whirlpool's Maytag refrigerator-freezer model "MSD2578VE." The Department opened this investigation and requested testing data from Whirlpool based on a complaint (April 12, 2010, "DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations"). After reviewing the data and testing this model, the Department has found the model to be compliant with the applicable efficiency standards and has closed the investigation. The Department takes credible allegations seriously and will continue to initiate investigations on products that are

359

DOE Proposes Higher Efficiency Standards for Refrigerators | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE Proposes Higher Efficiency Standards for Refrigerators DOE Proposes Higher Efficiency Standards for Refrigerators DOE Proposes Higher Efficiency Standards for Refrigerators September 28, 2010 - 12:00am Addthis WASHINGTON, DC - U.S. Energy Secretary Steven Chu today announced the release of a new proposed energy efficiency standard for residential refrigerators, refrigerator-freezers, and freezers. The standard, as proposed, could save consumers as much as $18.6 billion over thirty years. The Obama Administration has made efficiency standards a major priority as a way to save energy and money for American families and businesses. Since January 2009, the Department of Energy has finalized new efficiency standards for more than twenty household and commercial products, which will cumulatively save consumers between $250 billion and

360

North Star Refrigerator: Proposed Penalty (2013-CE-5355) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) March 26, 2013 DOE alleged in a Notice of Proposed Civil Penalty that North Star Refrigerator Co., Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. North Star Refrigerator: Proposed Penalty (2013-CE-5355) More Documents & Publications

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

North Star Refrigerator: Proposed Penalty (2013-CE-5355) | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) North Star Refrigerator: Proposed Penalty (2013-CE-5355) March 26, 2013 DOE alleged in a Notice of Proposed Civil Penalty that North Star Refrigerator Co., Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards. DOE regulations require a manufacturer (which includes importers) to submit reports certifying that its products have been tested and meet the applicable energy conservation standards. This civil penalty notice advises the company of the potential penalties and DOE's administrative process, including the company's right to a hearing. North Star Refrigerator: Proposed Penalty (2013-CE-5355) More Documents & Publications

362

DOE Closes Investigation of Whirlpool's Maytag Refrigerator | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

of Whirlpool's Maytag Refrigerator of Whirlpool's Maytag Refrigerator DOE Closes Investigation of Whirlpool's Maytag Refrigerator July 8, 2010 - 3:12pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Whirlpool's Maytag refrigerator-freezer model "MSD2578VE." The Department opened this investigation and requested testing data from Whirlpool based on a complaint (April 12, 2010, "DOE Opens Three Investigations into Alleged Refrigerator Efficiency Violations"). After reviewing the data and testing this model, the Department has found the model to be compliant with the applicable efficiency standards and has closed the investigation. The Department takes credible allegations seriously and will continue to initiate investigations on products that are

363

Condensation of refrigerants on vertical fluted tubes  

DOE Green Energy (OSTI)

Experiments were run to determine heat transfer performance of single vertical fluted tubes with selected fluids condensing on the outside. Working fluids included six fluorocarbons (Refrigerants 11, 21, 22, 113, 114, and 115) and a hydrocarbon (Refrigerant 600a or isobutane). The nine test tubes were of 2.54-cm (1-in.) nominal outside diameter and 1.2 m (4 ft) in length with from 0 (smooth) to 60 axial flutes. Condensing heat transfer coefficients ranged from 620 to 7900 W/m/sup 2/ . K (110 to 1400 Btu/hr . ft/sup 2/ . /sup 0/F) over the heat flux range of 2000 to 43,000 W/m/sup 2/ (920 to 13,600 Btu/hr . ft/sup 2/). All parameters are based on total condensing surface area. The data show that, for a given heat flux, a fluted tube can increase condensing coefficients up to 6.0 times smooth tube values. Further heat transfer enhancement was achieved by the use of drainage skirts on fluted tubes; these skirts effectively divided the 1.2-m (4-ft) tubes into two, four, and eight equal condensing lengths.

Combs, S.K.; Mailen, G.S.; Murphy, R.W.

1978-08-01T23:59:59.000Z

364

COMPUTER DESIGN AND OPTIMIZATION OF CRYOGENIC REFRIGERATION SYSTEMS  

E-Print Network (OSTI)

wells, fossil fuel burners, wet cooling towers, anddry cooling towers. Fluid properties are calculated usingthe water entering the cooling tower. Given the system state

green, M.A.

2011-01-01T23:59:59.000Z

365

Kitchen Ergonomic Refrigerated Solution: Design of a flexible fridge.  

E-Print Network (OSTI)

??This report describes the graduation thesis done by the IPD student Aitor Cuende for Fagor Electric Appliances, a Spanish Appliances manufacturer. The project has been (more)

Cuende Isuskiza, A.

2011-01-01T23:59:59.000Z

366

X-Y-theta cutting method  

DOE Patents (OSTI)

A method for machining a workpiece. The method includes the use of a rotary cutting tool mounted on the end of a movable arm. The arm is adapted to move in a plane perpendicular to the axis of rotation of the chips of material cutting tool. The cutting tool has cutting teeth to cut off of the workpiece in a predetermined size and shape to facilitate better removal of the chips from the workpiece. The teeth can be of different type and length to permit the tool to both rough cut and finish cut the workpiece during machining. The total depth of cut is divided by the number of tool teeth, so that the longest tool always perform finishing cut.

Bieg, L.F.

1991-01-01T23:59:59.000Z

367

X-Y-theta cutting method  

DOE Patents (OSTI)

A method for machining a workpiece. The method includes the use of a rotary cutting tool mounted on the end of a movable arm. The arm is adapted to move in a plane perpendicular to the axis of rotation of the chips of material cutting tool. The cutting tool has cutting teeth to cut off of the workpiece in a predetermined size and shape to facilitate better removal of the chips from the workpiece. The teeth can be of different type and length to permit the tool to both rough cut and finish cut the workpiece during machining. The total depth of cut is divided by the number of tool teeth, so that the longest tool always perform finishing cut.

Bieg, L.F.

1991-12-31T23:59:59.000Z

368

X-Z-Theta cutting method  

DOE Patents (OSTI)

A method for machining a workpiece. The method includes the use of a rotary cutting tool mounted on the end of a movable arm. The arm is adapted to move in a plane perpendicular to the axis of rotation of the cutting tool. The cutting tool has cutting teeth to cut chips of material off of the workpiece in a predetermined size and shape to facilitate better removal of the chips from the workpiece. The teeth can be of different type and length to permit the tool to both rough cut and finish cut the workpiece during machining. The total depth of cut is divided by the number of tool teeth, so that the longest tool always performs the finishing cut.

Bieg, L.F.

1993-01-12T23:59:59.000Z

369

SBIR Grant: ????????No-Vibration Agile Cryogenic Optical Refrigerator  

SciTech Connect

Optical refrigeration is currently the only all-solid-state cryocooling technology that has been demonstrated. Optical cryocoolers are devices that use laser light to cool small crystal or glass cooling elements. The cooling element absorbs the laser light and reradiates it at higher energy, an example of anti-Stokes fluorescence. The dif-ference between the energy of the outgoing and incoming light comes from the thermal energy of the cooling element, which in turn becomes colder. Entitled ???????¢????????????????No-Vibration Agile Cryocoolers using Optical Refrigeration,???????¢??????????????? this Phase I proposal directly addressed the continued development of the optical refrigerator components necessary to transition this scientific breakthrough into National Nu-clear Security Administration (NNSA) sensor applications in line with the objectives of topic 50b. ThermoDynamic Films LLC (TDF), in collaboration with the University of New Mexico (UNM), cooled an optical-refrigerator cooling element comprised of an ytterbium-doped yttrium lithium fluoride (Yb:YLF) crystal from room tempera-ture to 123 K with about 2% efficiency. This is the world record in optical refrigera-tion and an important step toward revolutionizing cryogenic systems for sensor ap-plications. During this period, they also designed and analyzed the crucial elements of a prototype optical refrigerator including the thermal link that connects the cool-ing element with the load.

Epstein, Richard

2013-04-09T23:59:59.000Z

370

Effect of parasitic refrigeration on the efficiency of magnetic liquefiers  

SciTech Connect

Our studies have shown that magnetic refrigerators have the potential to liquefy cryogens very efficiently. High efficiency is especially important for liquid hydrogen and natural gas applications where the liquefaction costs are a significant fraction of the total liquid cost. One of the characteristics of magnetic refrigerators is the requirement for a high-field superconducting magnet. Providing a 4.2-K bath for this magnet will require a small amount of parasitic refrigeration at 4.2 K even though the rest of the liquefier may be at 110 K (liquid natural gas) or higher. For several different refrigeration power levels at 4.2 K, we have calculated the efficiency of the magnetic liquefier as a function of power, temperature and the 4.2-K refrigerator efficiency. The results show that if the ratio of the thermal load at 4.2 K to the main refrigerator power is 0.001 or less, the effect on the efficiency of the liquefier is negligible at all temperatures below room temperature provided the 4.2-K refrigerator efficiency is high.

Barclay, J.A.; Stewart, W.F.

1982-01-01T23:59:59.000Z

371

A New Absorption Cycle: The Single-Effect Regenerative Absoprtion Refrigeration Cycle  

E-Print Network (OSTI)

REGENERATIVE ABSORPTION REFRIGERATION CYCLE ABSTRACT A new absorption cycle , using heat as the energy

Dao, K.

2011-01-01T23:59:59.000Z

372

Research of Refrigerant Phase-Change Stirling-Cycle Heat Engines  

Science Conference Proceedings (OSTI)

This paper firstly introduces the principles of Refrigerant Phase-Change Stirling-Cycle solar power towers This heat engines use solar reservoire. When the refrigerant in an engine cylinder absorbs heat from high-temperature heat sources, refrigerant ... Keywords: refrigerant phase-change cycle, heat engines, finite-time thermodynamics

Dezhong Huang; Fuer Wu

2011-01-01T23:59:59.000Z

373

New Regenerative Cycle for Vapor Compression Refrigeration  

Office of Scientific and Technical Information (OSTI)

SCIENTIFIC REPORT SCIENTIFIC REPORT Title Page Project Title: New Regenerative Cycle for Vapor Compression Refrigeration DOE Award Number: DE-FG36-04GO14327 Document Title: Final Scientific Report Period Covered by Report: September 30, 2004 to September 30, 2005 Name and Address of Recipient Organization: Magnetic Development, Inc., 68 Winterhill Road, Madison, CT 06443, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Contact Information: Mark J. Bergander, Ph.D., P.E., Principal Investigator, phone: 203-214-7247, fax: 203-421-7948, e-mail: mjb1000@aol.com Project Objective (as stated in the proposal): The main objective of this project is to confirm on a well-instrumented prototype the theoretically derived claims of higher efficiency and coefficient

374

Spray generators for absorption refrigeration systems  

DOE Patents (OSTI)

A spray generator for an absorption refrigeration system that includes a heat exchanger comprised of a multiplicity of variably spaced heat exchange tubes. The tubes are spaced close together near the top of the heat exchanger and spaced more widely apart near the bottom of the heat exchanger. Dilute absorbent solution is sprayed down through the heat exchanger. The close nesting of the tubes in the top portion of the heat exchanger retards liquid flow and aids heating of the solution. The wide spacing of the tubes in the lower section of the heat exchanger facilitate vapor flow out of the heat exchanger and eliminates liquid "blow-off". The top tubes are covered by a baffle to prevent the liquid solution from splashing out of the heat exchanger off of these top tubes.

Sibley, Howard W. (Baldwinsville, NY)

1979-06-19T23:59:59.000Z

375

Properties and Processes for Cryogenic Refrigeration R. Radebaugh, P. Bradley, M. Lewis (838), J. Gary, and A. O'Gallagher (ITL)  

E-Print Network (OSTI)

Properties and Processes for Cryogenic Refrigeration R. Radebaugh, P. Bradley, M. Lewis (838), J to characterize losses within cryocoolers and models need to be developed to optimize the design of such systems. Material properties at cryogenic temperatures also are needed by industry for the design of cryogenic

Magee, Joseph W.

376

EMSL: Science: Cross-Cutting Science  

NLE Websites -- All DOE Office Websites (Extended Search)

Cross-Cutting Science Areas Cross-cutting science EMSL's integrated approach supports science that doesn't fit easily into single categories. Here we capture EMSL's areas of...

377

Simplest optimal cutting patterns for equal rectangles  

Science Conference Proceedings (OSTI)

This paper presents branch-and-bound algorithms that can guarantee the simplest optimal cutting patterns of equal rectangles. An existing linear algorithm determines the global upper bound exactly. The branching process ends when a branch of a lower ... Keywords: Cutting stock problem, Optimization, Two-dimensional cutting

Yaodong Cui

2006-11-01T23:59:59.000Z

378

Modeling the effects of Refrigerant Charging on Air Conditioner Performance Characteristics For Three Expansion Devices  

E-Print Network (OSTI)

An experimental and analytical study concerned with the off-design refrigerant charging of air conditioners is presented. A series of experiments were conducted to characterize the effects of refrigerant charge and type of expansion device on the system performance (capacity, EER, SEER, etc.) of an air conditioner. All experiments were performed according to the ASHRAE Standard [1983]. The effects of off-design refrigerant charge in the system, type of expansion device (capillary tube, TXV, and short-tube orifice), and outdoor dry-bulb temperature (82 to l00F) on the wet and dry steady state and cyclic tests are addressed in this study. The fully charged condition was established as a base case for all the expansion device systems. A full charge was obtained by charging the unit to the superheat or subcooled condition specified by the manufacturer charging chan. Once the full charge was determined, refrigerant was then added in 5% increments from -20% of full charge to +20% of full charge to cover the full range of charging conditions for a particular expansion device being tested. The investigation of off-design charging indicated that the system performance variables (total capacity, EER, and SEER) of the unit with capillary tube were more sensitive to off-design charging than the systems with TXV and short-tube orifice. From -20% to +20% charging, the capacity and EER showed a strong dependence on the outdoor temperature, but varied little with charge for the TXV and short-tube orifice expansion systems. A -20% charging resulted in a 21% reduction in SEER while a +20% charging produced an 11% reduction in SEER for the unit with capillary tube. For the TXV, SEER dropped 2% and 8% for -20% and +20% refrigerant charging, respectively. The SEER was constant at 9.4 for all the charging condition except for -5% charging where it peaked to 9.9 for the short-tube orifice expansion system. This trend would suggest that the range of sensitivity of a short-tube orifice system is confined within a small refrigerant charge. A new heat exchanger model based on tube-by-tube simulation was developed and integrated into the ORNL heat pump model. The model was capable of simulating the steady state response of a vapor compression air-to-air heat pump and air conditioner commonly used in residential applications. The simulated results were compared with laboratory tests at two outdoor temperatures. It was found that the ORNL model estimates were within an average of 3% of the experimental results from - 10% to +10% charging conditions. The model predicted the system performance up to 8% higher than measured results at +/-20% and +/-15% charging conditions. Among the eight void fraction models studied, the Hughmark model showed the best agreement between superheat and subcooled temperatures, refrigerant flow rate and capacity and the measured results.

Farzad, Mohsen

1990-08-01T23:59:59.000Z

379

Property:Building/SPElectrtyUsePercRefrigeration | Open Energy Information  

Open Energy Info (EERE)

SPElectrtyUsePercRefrigeration SPElectrtyUsePercRefrigeration Jump to: navigation, search This is a property of type String. Refrigeration Pages using the property "Building/SPElectrtyUsePercRefrigeration" Showing 25 pages using this property. (previous 25) (next 25) S Sweden Building 05K0001 + 0.0 + Sweden Building 05K0002 + 0.0 + Sweden Building 05K0003 + 0.0 + Sweden Building 05K0004 + 0.0 + Sweden Building 05K0005 + 0.0 + Sweden Building 05K0006 + 4.24846345193 + Sweden Building 05K0007 + 0.0 + Sweden Building 05K0008 + 0.0 + Sweden Building 05K0009 + 0.0 + Sweden Building 05K0010 + 24.6944086225 + Sweden Building 05K0011 + 0.0 + Sweden Building 05K0012 + 0.0 + Sweden Building 05K0013 + 1.29913989581 + Sweden Building 05K0014 + 7.46645043826 + Sweden Building 05K0015 + 0.0 +

380

DOE Reaches Agreement with LG Electronics, USA, On Refrigerator Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Reaches Agreement with LG Electronics, USA, On Refrigerator Reaches Agreement with LG Electronics, USA, On Refrigerator Energy Matter DOE Reaches Agreement with LG Electronics, USA, On Refrigerator Energy Matter November 14, 2008 - 4:47pm Addthis ENERGY STAR® Program Continues to Help American Consumers Make Energy Efficient Choices WASHINGTON - The U.S. Department of Energy (DOE) today announced an agreement with LG Electronics, USA, Inc. (LG), resolving concerns related to energy usage measurements reported on LG French Door refrigerators with through-the-door ice and water service. The ENERGY STAR® program helps American consumers make energy efficient choices, saving billions of dollars while protecting the environment by using identified energy efficient products and practices. "DOE believes that the actions LG plans to take will benefit consumers and

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Computer program for determining the thermodynamic properties of Freon refrigerants  

DOE Green Energy (OSTI)

This program was written to be used as a subroutine. The program determines the thermodynamics of Freon refrigerants. The following refrigerants can be analyzed F-11, F-12, F-13, F-14, F-21, F-22, F-23, F-113, and F-114. The subroutine can evaluate a thermodynamic state for these refrigerants given any of the following pairs of state quantities: pressure and quality, pressure and entropy, pressure and enthalpy, temperature and quality, temperature and specific volume, and temperature and pressure. These six pairs of knowns allow the user to analyze any thermodynamic cycle utilizing a refrigerant as the working fluid. The Downing form of the Martin equation of state was used. This report contains a brief description, flow chart and listing of all subroutines required.

Riemer, D.H.; Jacobs, H.R.; Boehm, R.F.

1977-12-01T23:59:59.000Z

382

Computer program for determining the thermodynamic properties of freon refrigerants  

DOE Green Energy (OSTI)

This program was written to be used as a subroutine. The program determines the thermodynamics of Freon refrigerants. The following refrigerants can be analyzed F-11, F-12, F-13, F-14, F-21, F-22, F-23, F-113, and F-114. The subroutine can evaluate a thermodynamic state for these refrigerants given any of the following pairs of state quantities: pressure and quality, pressure and entropy, pressure and enthalpy, temperature and quality, temperature and specific volume and temperature and pressure. These six pairs of knowns allow the user to analyze any thermodynamic cycle utilizing a refrigerant as the working fluid. The Downing form of the Martin equation of state was used. A brief description, flow chart, and listing of all subroutines required are presented.

Riemer, D.H.; Jacobs, H.R.; Boehm, R.F.

1976-07-01T23:59:59.000Z

383

Improved Algorithm and Simulation of the Provision Refrigerating Unit  

Science Conference Proceedings (OSTI)

The dynamic model of reciprocating provision cooling plant is presented, and the algorithm of the model is amended, through the method of quoting an unknown variable, which is enthalpy of the refrigerant at the compressor outlet. Dynamic simulation of ...

HE Zhi-bin; ZHANG Jun-dong; SUN Yu-qing; ZENG Hong; GAN Hui-bing

2007-09-01T23:59:59.000Z

384

DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star  

NLE Websites -- All DOE Office Websites (Extended Search)

Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements DOE Testing Reveals Samsung Refrigerator Does Not Meet Energy Star Requirements March 16, 2010 - 4:28pm Addthis DOE-initiated testing has revealed that a Samsung refrigerator (model RF26VAB), which the company had claimed was Energy Star compliant, consumed more energy than permitted by the Energy Star program. Test results for the Samsung model at issue show that, when tested in accordance with DOE's test procedure, it consumed between 7 and 11.4 percent more energy than the Energy Star requirement. Samsung is no longer manufacturing this model, although it may still be available from some retail outlets. Based on this testing, DOE is referring Samsung Model RF26VAB to the U.S.

385

Covered Product Category: Residential Refrigerators | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Residential Refrigerators Residential Refrigerators Covered Product Category: Residential Refrigerators October 7, 2013 - 11:19am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including residential refrigerators, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

386

Product Standards for Refrigerators (Japan) | Open Energy Information  

Open Energy Info (EERE)

Product Standards for Refrigerators (Japan) Product Standards for Refrigerators (Japan) Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Product Standards for Refrigerators (Japan) Focus Area: Appliances & Equipment Topics: Policy Impacts Website: www.eccj.or.jp/top_runner/pdf/tr_re-freez_Jul.2006.pdf Equivalent URI: cleanenergysolutions.org/content/product-standards-refrigerators-japan Language: English Policies: "Deployment Programs,Regulations" is not in the list of possible values (Deployment Programs, Financial Incentives, Regulations) for this property. DeploymentPrograms: Industry Codes & Standards Regulations: Appliance & Equipment Standards and Required Labeling This Energy Conservation Center Japan (ECCJ) document was created as a guide in response to its newly established set of standards and labelling

387

Covered Product Category: Residential Refrigerators | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Refrigerators Refrigerators Covered Product Category: Residential Refrigerators October 7, 2013 - 11:19am Addthis ENERGY STAR Qualified Products FEMP provides acquisition guidance across a variety of product categories, including residential refrigerators, which are an ENERGY STAR®-qualified product category. Federal laws and executive orders mandate that agencies meet these efficiency requirements in all procurement and acquisition actions that are not specifically exempted by law. Most manufacturers display the ENERGY STAR label on complying models. For a model not displaying this label, check the manufacturer's literature to determine if it meets the efficiency requirements outlined by ENERGY STAR. Performance Requirements for Federal Purchases For the most up-to-date efficiency levels required by ENERGY STAR, look for

388

Energy Department Announces More Stringent Criteria for ENERGY STAR Refrigerators  

Energy.gov (U.S. Department of Energy (DOE))

WASHINGTON, DC - The U.S. Department of Energy (DOE) today announced increased energy efficient criteria for refrigerators carrying the ENERGY STAR label. In order to qualify, full-size...

389

Commercial Refrigerator Door: Proposed Penalty (2013-CE-5351)  

Energy.gov (U.S. Department of Energy (DOE))

DOE alleged in a Notice of Proposed Civil Penalty that Commercial Refrigerator Door Company, Inc. failed to certify a variety of walk-in cooler or freezer components as compliant with the applicable energy conservation standards.

390

Detailed CFD modelling of open refrigerated display cabinets  

Science Conference Proceedings (OSTI)

A comprehensive and detailed computational fluid dynamics (CFDs) modelling of air flow and heat transfer in an open refrigerated display cabinet (ORDC) is performed in this study. The physical-mathematical model considers the flow through the internal ...

Pedro Dinis Gaspar; L. C. Carrilho Gonalves; R. A. Pitarma

2012-01-01T23:59:59.000Z

391

Energy Consumption of Refrigerators in Ghana - Outcomes of Household...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy Consumption of Refrigerators in Ghana - Outcomes of Household Surveys Speaker(s): Essel Ben Hagan Date: July 12, 2007 - 12:00pm Location: 90-3122 Seminar HostPoint of...

392

Extreme solid state refrigeration using nanostructured Bi-Te alloys.  

SciTech Connect

Materials are desperately needed for cryogenic solid state refrigeration. We have investigated nanostructured Bi-Te alloys for their potential use in Ettingshausen refrigeration to liquid nitrogen temperatures. These alloys form alternating layers of Bi{sub 2} and Bi{sub 2}Te{sub 3} blocks in equilibrium. The composition Bi{sub 4}Te{sub 3} was identified as having the greatest potential for having a high Ettingshausen figure of merit. Both single crystal and polycrystalline forms of this material were synthesized. After evaluating the Ettingshausen figure of merit for a large, high quality polycrystal, we simulated the limits of practical refrigeration in this material from 200 to 77 K using a simple device model. The band structure was also computed and compared to experiments. We discuss the crystal growth, transport physics, and practical refrigeration potential of Bi-Te alloys.

Lima Sharma, Ana L. (San Jose State University, San Jose, CA); Spataru, Dan Catalin; Medlin, Douglas L.; Sharma, Peter Anand; Morales, Alfredo Martin

2009-09-01T23:59:59.000Z

393

Advanced refrigeration system for the Brookhaven superconducting cable project  

SciTech Connect

A description is given of a basic supercritical refrigerator. The present status of the cable enclosure and the types of cooling schemes being considered are presented with some examples of laboratory results and computer analysis. (MOW)

Jensen, J.E.

1975-01-01T23:59:59.000Z

394

Removing Odors from Refrigerators and Freezers after Food has Spoiled  

E-Print Network (OSTI)

If food has spoiled in a refrigerator or freezer because of a power outage or some other reason, undesirable odors can result. This publication explains how to eliminate odors from these appliances.

FCS Project Team - FDRM UNIT

2005-09-30T23:59:59.000Z

395

Optimization Online - A cutting surface algorithm for semi-infinite ...  

E-Print Network (OSTI)

Jun 14, 2013 ... The combination of this distribution optimization method and the cutting ... column generation, cutting surface methods, cutting plane methods,...

396

ARI delegation to Japan on Alternative Refrigerants. [Foreign Trip Report  

SciTech Connect

Researchers from ARI member companies spoke at the International Conference on Alternative Refrigerants in Tokyo and visited several Japanese organizations for the purpose of exchanging information on alternative refrigerants. The specific purpose of the meetings was to review the methods being utilized to screen alternatives to CFCs and HCFCs: materials compatibility screening methods, lubricant testing techniques, as well as flammability studies. A list of papers presented at the conference is included.

Not Available

1993-02-01T23:59:59.000Z

397

Hybrid refrigeration/sorption solar-cooling systems  

DOE Green Energy (OSTI)

The hybrid refrigeration/sorption concept is a technically feasible approach to solar cooling which has not yet been systematically evaluated. Various system configurations are possible, each with advantages and disadvantages relative to the others, and with respect to solar cooling systems based on the individual absorption, Rankine, and desiccant technologies. Conventional cooling and dehumidification, sorption dehumidification, and the effects on the refrigeration unit of adding a dehumidifier are discussed.

Curran, H.M.

1981-08-01T23:59:59.000Z

398

Transport Refrigeration Equipment: Analysis of Emissions and Economics of Electrification  

Science Conference Proceedings (OSTI)

Most refrigerated trucks, trailers, and ocean containers used to transport, deliver, and store fresh and frozen foods utilize an auxiliary diesel engine (10 to 34 hp) to operate on-board refrigeration systems. These engines are vital for product temperature control while the vehicle is on the road, but also idle while the truck is parked at a facility, pre-cooling, loading, unloading, or waiting to be dispatched. As a result, large distribution centers can experience high concentrations of pollutants and...

2004-06-30T23:59:59.000Z

399

Compatibility of refrigerants and lubricants with engineering plastics  

Science Conference Proceedings (OSTI)

All seven oil immersion studies are complete at both temperatures. Nine out of ten refrigerant ambient immersion studies are complete including 60C (140F) for R-123. All 22 plastic test materials have been molded into test bars. All test bars have been quality controlled for physical consistency and integrity. All 22 test chambers are functional. Creep loads have been increased to 25% of ultimate tensile. Refrigerant has solubilities of Emery 2927 with R-22 and 134a are complete.

Cavestri, R.C.

1992-07-01T23:59:59.000Z

400

Heat exchanger bypass system for an absorption refrigeration system  

DOE Patents (OSTI)

A heat exchanger bypass system for an absorption refrigeration system is disclosed. The bypass system operates to pass strong solution from the generator around the heat exchanger to the absorber of the absorption refrigeration system when strong solution builds up in the generator above a selected level indicative of solidification of strong solution in the heat exchanger or other such blockage. The bypass system includes a bypass line with a gooseneck located in the generator for controlling flow of strong solution into the bypass line and for preventing refrigerant vapor in the generator from entering the bypass line during normal operation of the refrigeration system. Also, the bypass line includes a trap section filled with liquid for providing a barrier to maintain the normal pressure difference between the generator and the absorber even when the gooseneck of the bypass line is exposed to refrigerant vapor in the generator. Strong solution, which may accumulate in the trap section of the bypass line, is diluted, to prevent solidification, by supplying weak solution to the trap section from a purge system for the absorption refrigeration system.

Reimann, Robert C. (Lafayette, NY)

1984-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Polarized target with dilution refrigerator: why and how  

DOE Green Energy (OSTI)

Polarized targets using dilution refrigerators have several advantages over targets of He/sup 3/ cryostats for some polarization experiments. One of the advantages is in the long nuclear spin lattice relaxation time in quite low temperatures. It permits holding the target polarization in a magnetic field different from the polarizing field. Another merit is in the fact that one can obtain higher polarization in a dilution refrigerator than in a He/sup 3/ cryostat, especially in the case of deuterons. These facts suggest various applications of the target with a dilution refrigerator, such as a spin-frozen target for spin-rotation parameter measurements, a target for spin effects in inelastic scattering, high polarized deuteron target, and so on. Furthermore, one can hopefully make a highly polarized HD target with further improvements of the dilution refrigerator. The possibility of the solid hydrogen polarization is also discussed. Finally, the principle of the dilution refrigerator and the special features of the refrigerator for the polarized target are briefly described. 7 figures.

Masaike, A.

1977-09-01T23:59:59.000Z

402

Technical support document: Energy efficiency standards for consumer products: Refrigerators, refrigerator-freezers, and freezers including draft environmental assessment, regulatory impact analysis  

Science Conference Proceedings (OSTI)

The Energy Policy and Conservation Act (P.L. 94-163), as amended by the National Appliance Energy Conservation Act of 1987 (P.L. 100-12) and by the National Appliance Energy Conservation Amendments of 1988 (P.L. 100-357), and by the Energy Policy Act of 1992 (P.L. 102-486), provides energy conservation standards for 12 of the 13 types of consumer products` covered by the Act, and authorizes the Secretary of Energy to prescribe amended or new energy standards for each type (or class) of covered product. The assessment of the proposed standards for refrigerators, refrigerator-freezers, and freezers presented in this document is designed to evaluate their economic impacts according to the criteria in the Act. It includes an engineering analysis of the cost and performance of design options to improve the efficiency of the products; forecasts of the number and average efficiency of products sold, the amount of energy the products will consume, and their prices and operating expenses; a determination of change in investment, revenues, and costs to manufacturers of the products; a calculation of the costs and benefits to consumers, electric utilities, and the nation as a whole; and an assessment of the environmental impacts of the proposed standards.

NONE

1995-07-01T23:59:59.000Z

403

Refinery Waste Heat Ammonia Absorption Refrigeration Plant (WHAARP) Recovers LPG's and Gasoline, Saves Energy, and Reduces Air Pollution  

E-Print Network (OSTI)

A first-of-its-kind Waste Heat Ammonia Absorption Refrigeration Plant (WHAARP) was installed by Planetec Utility Services Co., Inc. in partnership with Energy Concepts Co. at Ultramar Diamond Shamrock's 30,000 barrel per day refinery in Denver, Colorado. The refrigeration unit is designed to provide refrigeration for two process units at the refinery while utilizing waste heat as the energy source. The added refrigeration capacity benefits the refinery by recovering salable products, debottlenecking process units, avoiding additional electrical demand, and reducing the refinery Energy Intensity Index. In addition, the WHAARP unit lowers air pollutant emissions by reducing excess fuel gas that is combusted in the refinery flare. A comprehensive utility and process efficiency Master Plan developed for the Denver refinery by Planetec provided the necessary platform for implementing this distinctive project. The $2.3 million WHAARP system was paid for in part by a $760,000 grant from the U.S. Department of Energy, as part of their "Industry of the Future Program". Total combined benefits are projected to be approximately $1 million/year with a 1.6 year simple payback including the grant funding.

Brant, B.; Brueske, S.; Erickson, D.; Papar, R.

1998-04-01T23:59:59.000Z

404

Free-piston cutting machine  

DOE Patents (OSTI)

A cutting machine includes a gun barrel for receiving a projectile. A compression tube is disposed in flow communication with the barrel and includes a piston therein. A reservoir is disposed in flow communication with the tube and receives a first gas under pressure. A second gas fills the compression tube on a front face of the piston. And, the pressurized first gas is discharged into the tube on a back face of the piston to accelerate the piston through the tube for compressing the second gas, and in turn launching the projectile through the barrel to impact a workpiece.

Ciccarelli, Gaby (East Setauket, NY); Subudhi, Manomohan (East Setauket, NY); Hall, Robert E. (Port Jefferson, NY)

2000-01-01T23:59:59.000Z

405

Heat pump employing optimal refrigerant compressor for low pressure ratio applications  

DOE Patents (OSTI)

What is disclosed is a heat pump apparatus for conditioning a fluid characterized by a fluid handler for circulating the fluid in heat exchange relationship with a refrigerant fluid; two refrigerant heat exchangers; one for effecting the heat exchange with the fluid and a second refrigerant-heat exchange fluid heat exchanger for effecting a low pressure ratio of compression of the refrigerant; a rotary compressor for compressing the refrigerant with low power consumption at the low pressure ratio; at least one throttling valve connecting at the inlet side of heat exchanger in which liquid refrigerant is vaporized; a refrigerant circuit serially connecting the above elements; refrigerant in the circuit; a source of heat exchange fluid; heat exchange fluid circulating device and heat exchange fluid circuit for circulating the heat exchange fluid in heat exchange relationship with the refrigerant.

Ecker, Amir L. (Dallas, TX)

1982-01-01T23:59:59.000Z

406

Design  

NLE Websites -- All DOE Office Websites (Extended Search)

Design Design of a Multithreaded Barnes-Hut Algorithm for Multicore Clusters Technical Report Junchao Zhang and Babak Behzad Department of Computer Science, University of Illinois at Urbana-Champaign {jczhang, bbehza2}@illinois.edu Marc Snir Department of Computer Science, University of Illinois at Urbana-Champaign and MCS Division, Argonne National Laboratory snir@anl.gov Abstract We describe in this paper an implementation of the Barnes-Hut al- gorithm on multicore clusters. Based on a partitioned global ad- dress space (PGAS) library, the design integrates intranode mul- tithreading and internode one-sided communication, exemplifying a PGAS + X programming style. Within a node, the computation is decomposed into tasks (subtasks), and multitasking is used to hide network latency. We study the tradeoffs between locality in private caches and locality in shared caches

407

Demand Response Opportunities in Industrial Refrigerated Warehouses in  

NLE Websites -- All DOE Office Websites (Extended Search)

Response Opportunities in Industrial Refrigerated Warehouses in Response Opportunities in Industrial Refrigerated Warehouses in California Title Demand Response Opportunities in Industrial Refrigerated Warehouses in California Publication Type Conference Paper LBNL Report Number LBNL-4837E Year of Publication 2011 Authors Goli, Sasank, Aimee T. McKane, and Daniel Olsen Conference Name 2011 ACEEE Summer Study on Energy Efficiency in Industry Date Published 08/2011 Conference Location Niagara Falls, NY Keywords market sectors, openadr, refrigerated warehouses Abstract Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

408

How refrigeration, heating, ventilation, and air conditioning service technicians learn from troubleshooting (Dissertation ABstract)  

E-Print Network (OSTI)

The purpose of this study was to understand how refrigeration, heating, ventilation, and air conditioning (RHVAC) service technicians (techs) learned from troubleshooting. This understanding resulted in instructional and curricular strategies designed to help community colleges prepare vocational students to learn more effectively from informal workplace learning. RHVAC techs were studied because they increasingly learn their trade skills through a combination of formal schooling and informal workplace learning, though many still learn their trade almost exclusively in the workplace. Even those with formal training require considerable workplace experience to become fully competent. Troubleshooting is a major job function for RHVAC service techs, and troubleshooting

Denis F. H. Green

2006-01-01T23:59:59.000Z

409

Kinetic electrocaloric effect and giant net cooling of lead-free ferroelectric refrigerants  

SciTech Connect

The electrocaloric effect of BaTiO{sub 3} multilayer thick film structure was investigated by direct measurement using differential scanning calorimeter. The samples show a giant electrocaloric effect of 0.89 J/g under E=176 kV/cm, which also depends on the varying rate of applied field, following a general power-law relation. Based on the large net-cooling (0.37 J/g) resulting from the difference in the varying rates of rising and falling fields, the kinetic electrocaloric effect provides a solution for the design of refrigeration cycle in ferroelectric microrefrigerator.

Bai Yang [Department of Mechanical Engineering, Hong Kong Polytechnic University, Hung Hom, Kowloon (Hong Kong); Key Laboratory of Environmental Fracture, University of Science and Technology Beijing, Ministry of Education, Beijing 100083 (China); Zheng Guangping; Shi Sanqiang [Department of Mechanical Engineering, Hong Kong Polytechnic University, Hung Hom, Kowloon (Hong Kong)

2010-11-15T23:59:59.000Z

410

Nanoscale devices for solid state refrigeration and power generation, Twentieth Annual  

E-Print Network (OSTI)

A brief review of various techniques to engineer nanoscale thermal and electrical properties of materials is given. The main emphasis is on various energy conversion mechanisms, particularly, thermo electric refrigeration and power generation. Recent experimental and theoretical results on superlattice and quantum dot thermoelectrics and solidstate and vacuum thermionic thin film devices are reviewed. We also present an overview of the research activities at the multi university Thermionic Energy Conversion Center on the design of solid-state and vacuum devices that could convert heat into electricity with hot side temperatures ranging from 300 to 650C and with high conversion efficiency.

Ali Shakouri

2004-01-01T23:59:59.000Z

411

L&E: Refrigerated Display Case | The Better Buildings Alliance  

NLE Websites -- All DOE Office Websites (Extended Search)

Lighting & Electrical » Adopt the Lighting & Electrical » Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs Activities Technology Solutions Teams Lighting & Electrical Space Conditioning Plug & Process Loads Food Service Refrigeration Laboratories Energy Management & Information Systems Public Sector Teams Market Solutions Teams Adopt the refrigerated display case lighting performance specification and start saving on your case lighting costs The LED Refrigerated Display Case Lighting Specification delivers nearly 50% energy savings compared to typical display case lighting. If all retail refrigerated display cases switched today to LED systems, over 2.1 TWh of electricity could be saved annually. LED Refrigerated Display Case Lighting Specification

412

Method of removing an immiscible lubricant from a refrigeration system and apparatus for same  

DOE Patents (OSTI)

A method of separating an immiscible lubricant from a liquid refrigerant in a refrigerating system including a compressor, a condenser, an expansion device and an evaporator, wherein the expansion device is connected to the condenser by a liquid refrigerant flow line for liquid refrigerant and immiscible lubricant. The method comprising slowing the rate of flow of the liquid refrigerant and immiscible lubricant between the condenser and the expansion device such that the liquid refrigerant and the immiscible lubricant separate based upon differences in density. The method also comprises collecting the separated immiscible lubricant in a collection chamber in fluid communication with the separated immiscible lubricant. Apparatus for performing the method is also disclosed.

Spauschus, Hans O. (Stockbridge, GA); Starr, Thomas L. (Roswell, GA)

1999-01-01T23:59:59.000Z

413

Cutting sound enhancement system for mining machines  

DOE Patents (OSTI)

A cutting sound enhancement system (10) for transmitting an audible signal from the cutting head (101) of a piece of mine machinery (100) to an operator at a remote station (200), wherein, the operator using a headphone unit (14) can monitor the difference in sounds being made solely by the cutting head (101) to determine the location of the roof, floor, and walls of a coal seam (50).

Leigh, Michael C. (Coal Center, PA); Kwitowski, August J. (Clairton, PA)

1992-01-01T23:59:59.000Z

414

Modeling of Production Metal Cutting Processes  

Science Conference Proceedings (OSTI)

... oblique cutting, and nose turning. Finally, a system-level mechanistic machining model is briefly described for turning, milling, and drilling, and a ...

2011-01-12T23:59:59.000Z

415

Advanced cryogenics for cutting tools. Final report  

SciTech Connect

The purpose of the investigation was to determine if cryogenic treatment improved the life and cost effectiveness of perishable cutting tools over other treatments or coatings. Test results showed that in five of seven of the perishable cutting tools tested there was no improvement in tool life. The other two tools showed a small gain in tool life, but not as much as when switching manufacturers of the cutting tool. The following conclusions were drawn from this study: (1) titanium nitride coatings are more effective than cryogenic treatment in increasing the life of perishable cutting tools made from all cutting tool materials, (2) cryogenic treatment may increase tool life if the cutting tool is improperly heat treated during its origination, and (3) cryogenic treatment was only effective on those tools made from less sophisticated high speed tool steels. As a part of a recent detailed investigation, four cutting tool manufacturers and two cutting tool laboratories were queried and none could supply any data to substantiate cryogenic treatment of perishable cutting tools.

Lazarus, L.J.

1996-10-01T23:59:59.000Z

416

Solutions for Summer Electric Power Shortages: Demand Response and its Applications in Air Conditioning and Refrigerating Systems  

E-Print Network (OSTI)

LBNL-63806 Refrigeration, Air Conditioning, & Electric Powerand its Applications in Air Conditioning and Refrigeratingand its applications in Air Conditioning and refrigerating

Han, Junqiao; Piette, Mary Ann

2008-01-01T23:59:59.000Z

417

Ultrasonic cleaner cuts costs, enhances safety | Y-12 National Security  

NLE Websites -- All DOE Office Websites (Extended Search)

Ultrasonic Ultrasonic cleaner cuts ... Ultrasonic cleaner cuts costs, enhances safety Posted: August 27, 2013 - 1:42pm System engineers, Facility Design engineers, Production personnel and craft workers collaborated on a project to significantly upgrade a 30-year-old cleaning unit essential to parts-cleaning operations. "The work is interesting, but it's the people that get you back here every day." That's Facility Design engineer Ernie Lamb's summation of another successful team effort at Y-12, this time for the ultrasonic cleaner in Building 9201-1, or Alpha 1. Last fall the 30-year-old cleaning unit, essential to the building's parts-cleaning operations, was having difficulties. Today "the cleaner works better than ever," a result of a collaboration of system engineers,

418

Energy Efficiency Evaluation of Refrigeration Technologies in Combined Cooling, Heating and Power Systems  

E-Print Network (OSTI)

With development of absorption refrigeration technology, the cooling requirement can be met using various optional refrigeration technologies in a CCHP system, including compression refrigeration, steam double-effect absorption refrigeration, steam single-effect absorption refrigeration, flue gas absorption refrigeration and hot water absorption refrigeration, etc. As a universal criterion, the COP coefficient cannot reflect the difference in availability of driving energy for different chillers. Exergy efficiency of optional chillers in CCHP system was analyzed and compared, which can be regarded as an important reference criterion in comparison of energy efficiency. Furthermore, a new index, relative electricity saving ratio, was put forward for evaluating end energy efficiency of all kinds of chillers in a CCHP system, which indicates actual energy or electricity saving ratio for different absorption chillers with various parameters in contrast to the reference electricity-driven refrigeration scheme.

Zuo, Z.; Hu, W.

2006-01-01T23:59:59.000Z

419

The Performance Analysis of a Quantum Brayton Refrigeration Cycle with an Ideal Bose Gas  

Science Conference Proceedings (OSTI)

A Brayton refrigeration cycle using an ideal Bose gas as the working substance is simply referred to as a quantum Brayton refrigeration cycle, which consists of two constant-pressure and two adiabatic processes. The influence of quantum degeneracy on ...

Bihong Lin; Jincan Chen

2003-05-01T23:59:59.000Z

420

DOE Closes Investigation into Energy Efficiency of Viking Refrigerator |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Closes Investigation into Energy Efficiency of Viking Closes Investigation into Energy Efficiency of Viking Refrigerator DOE Closes Investigation into Energy Efficiency of Viking Refrigerator November 9, 2010 - 7:30pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Viking Range Corporation's refrigerator-freezer model VCSB542. The Department initiated this investigation in response to allegations that the model failed to meet federal energy efficiency standards. After reviewing data provided by Viking for this model, the Department issued a testing demand on June 16, 2010 and initially tested four units, one of which was defective and replaced by a fifth unit. The test results showed that two Viking units failed the federal energy standard for maximum energy use, while two passed. Because of the wide variation in the

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

DOE Closes Investigation into Energy Efficiency of Viking Refrigerator |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

into Energy Efficiency of Viking into Energy Efficiency of Viking Refrigerator DOE Closes Investigation into Energy Efficiency of Viking Refrigerator November 9, 2010 - 7:30pm Addthis The Department of Energy has closed its investigation into the energy efficiency of Viking Range Corporation's refrigerator-freezer model VCSB542. The Department initiated this investigation in response to allegations that the model failed to meet federal energy efficiency standards. After reviewing data provided by Viking for this model, the Department issued a testing demand on June 16, 2010 and initially tested four units, one of which was defective and replaced by a fifth unit. The test results showed that two Viking units failed the federal energy standard for maximum energy use, while two passed. Because of the wide variation in the

422

South Africa Sectoral Study on Climate and Refrigeration Technology in  

Open Energy Info (EERE)

South Africa Sectoral Study on Climate and Refrigeration Technology in South Africa Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Jump to: navigation, search Name South Africa-Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics Low emission development planning, -LEDS, -NAMA, Market analysis Website http://www.giz.de/en/ Program Start 2010 Program End 2012 Country South Africa Southern Africa

423

India Sectoral Study on Climate and Refrigeration Technology in Developing  

Open Energy Info (EERE)

India Sectoral Study on Climate and Refrigeration Technology in Developing India Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Jump to: navigation, search Name India-Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics Low emission development planning, -LEDS, -NAMA, Market analysis Website http://www.giz.de/en/ Program Start 2010 Program End 2012 Country India Southern Asia References Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ)[1]

424

Mexico Sectoral Study on Climate and Refrigeration Technology in Developing  

Open Energy Info (EERE)

Mexico Sectoral Study on Climate and Refrigeration Technology in Developing Mexico Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Jump to: navigation, search Name Mexico-Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics Low emission development planning, -LEDS, -NAMA, Market analysis Website http://www.giz.de/en/ Program Start 2010 Program End 2012 Country Mexico Central America References Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ)[1]

425

Sectoral Study on Climate and Refrigeration Technology in Developing  

Open Energy Info (EERE)

Study on Climate and Refrigeration Technology in Developing Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Jump to: navigation, search Name Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics Low emission development planning, -LEDS, -NAMA, Market analysis Website http://www.giz.de/en/ Program Start 2010 Program End 2012 Country India, Mexico, South Africa, Thailand Southern Asia, Central America, Southern Africa, South-Eastern Asia

426

Energy Efficiency Standards for Refrigerators in Brazil: A Methodology for  

Open Energy Info (EERE)

Energy Efficiency Standards for Refrigerators in Brazil: A Methodology for Energy Efficiency Standards for Refrigerators in Brazil: A Methodology for Impact Evaluation Jump to: navigation, search Tool Summary LAUNCH TOOL Name: Energy Efficiency Standards for Refrigerators in Brazil: A Methodology for Impact Evaluation Focus Area: Energy Efficiency Topics: Potentials & Scenarios Website: www.scribd.com/doc/34712276/Energy-efficiency-standards-for-refrigerat Equivalent URI: cleanenergysolutions.org/content/energy-efficiency-standards-refrigera Language: English Policies: Regulations Regulations: "Appliance & Equipment Standards and Required Labeling,Emissions Standards" is not in the list of possible values (Agriculture Efficiency Requirements, Appliance & Equipment Standards and Required Labeling, Audit Requirements, Building Certification, Building Codes, Cost Recovery/Allocation, Emissions Mitigation Scheme, Emissions Standards, Enabling Legislation, Energy Standards, Feebates, Feed-in Tariffs, Fuel Efficiency Standards, Incandescent Phase-Out, Mandates/Targets, Net Metering & Interconnection, Resource Integration Planning, Safety Standards, Upgrade Requirements, Utility/Electricity Service Costs) for this property.

427

Quantum spins mimic refrigerator magnets - Argonne National Laboratories,  

NLE Websites -- All DOE Office Websites (Extended Search)

Highlights > Quantum spins mimic refrigerator Highlights > Quantum spins mimic refrigerator magnets Quantum spins mimic refrigerator magnets By Joseph Bernstein * October 11, 2012 The behavior of magnetic moments in metal oxides such as layered iridium is dominated by strong spin-orbit coupling effects. In layered compounds such as Sr3Ir2O7 (shown on the left), the direction of these moments (blue arrows) is controlled at the quantum level by dipolar interactions that are akin to those of classical bar magnets. Another outcome is an unprecedented 'magnon gap' (shown at right), which was measured at the Argonne Advanced Photon Source and reveals that these underlying dipolar magnetic interactions are extremely strong. Current electronic devices depend on manipulating charge. Alternative approaches may rely on not only charge but also the spin of electrons.

428

Thailand Sectoral Study on Climate and Refrigeration Technology in  

Open Energy Info (EERE)

Thailand Sectoral Study on Climate and Refrigeration Technology in Thailand Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Jump to: navigation, search Name Thailand-Sectoral Study on Climate and Refrigeration Technology in Developing Countries and the Development of Methods and Instruments for Identifying Reduction Potential and Implementing NAMAs Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics Low emission development planning, -LEDS, -NAMA, Market analysis Website http://www.giz.de/en/ Program Start 2010 Program End 2012 Country Thailand South-Eastern Asia References Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ)[1]

429

Frost sensor for use in defrost controls for refrigeration  

DOE Patents (OSTI)

An apparatus and method for measuring the total thermal resistance to heat flow from the air to the evaporative cooler fins of a refrigeration system. The apparatus is a frost sensor that measures the reduction in heat flow due to the added thermal resistance of ice (reduced conduction) as well as the reduction in heat flow due to the blockage of airflow (reduced convection) from excessive ice formation. The sensor triggers a defrost cycle when needed, instead of on a timed interval. The invention is also a method for control of frost in a system that transfers heat from air to a refrigerant along a thermal path. The method involves measuring the thermal conductivity of the thermal path from the air to the refrigerant, recognizing a reduction in thermal conductivity due to the thermal insulation effect of the frost and due to the loss of airflow from excessive ice formation; and controlling the defrosting of the system.

French, Patrick D. (ADA Technologies, Inc. 8100 Shaffer Pkwy., Suite 130, Littleton, CO 80127-4107); Butz, James R. (ADA Technologies, Inc. 8100 Shaffer Pkwy., Suite 130, Littleton, CO 80127-4107); Veatch, Bradley D. (ADA Technologies, Inc. 8100 Shaffer Pkwy., Suite 130, Littleton, CO 80127-4107); O' Connor, Michael W. (ADA Technologies, Inc. 8100 Shaffer Pkwy., Suite 130, Littleton, CO 80127-4107)

2002-01-01T23:59:59.000Z

430

Retrofitting Doors on Open Refrigerated Cases  

NLE Websites -- All DOE Office Websites (Extended Search)

Retailer End Users Utilities and Efficiency Organizations Manufacturers and Equipment Suppliers Designers, Installers and Technicians 6 | Building Technologies Office...

431

DOE/EA-1643: Environmental Assessment for 10 CFR 431 Commercial Refrigeration Equipment (December 2008)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

ENVIRONMENTAL ASSESSMENT FOR ENVIRONMENTAL ASSESSMENT FOR 10 CFR Part 431 Energy Conservation Program for Commercial and Industrial Equipment: Energy Conservation Standards for Commercial Ice-Cream Freezers; Self-Contained Commercial Refrigerators, Commercial Freezers, and Commercial Refrigerator- Freezers without Doors; and Remote Condensing Commercial Refrigerators, Commercial Freezers, and Commercial Refrigerator-Freezers December 2008 CHAPTER 16. ENVIRONMENTAL IMPACT ANALYSIS TABLE OF CONTENTS 16.1 INTRODUCTION ............................................................................................................ 16-1 16.2 AIR QUALITY ANALYSIS ............................................................................................ 16-1

432

Refrigerant Properties: Commercial Cooling Update Issue 5, Rev. 6, September 1999  

Science Conference Proceedings (OSTI)

This Update describes the properties of existing and proposed refrigerants. Because many of these properties are measured by techniques that are still evolving, some of the values shown may change. The data included are from the most recently published sources. Properties covered include: ozone depletion potential, global warming potential, refrigeration capacity, energy efficiency, flammability, exposure limits,and refrigerant blends. A table conveniently compares traditional refrigerants in use, new re...

1999-09-30T23:59:59.000Z

433

Demand Response Opportunities in Industrial Refrigerated Warehouses in California  

Science Conference Proceedings (OSTI)

Industrial refrigerated warehouses that implemented energy efficiency measures and have centralized control systems can be excellent candidates for Automated Demand Response (Auto-DR) due to equipment synergies, and receptivity of facility managers to strategies that control energy costs without disrupting facility operations. Auto-DR utilizes OpenADR protocol for continuous and open communication signals over internet, allowing facilities to automate their Demand Response (DR). Refrigerated warehouses were selected for research because: They have significant power demand especially during utility peak periods; most processes are not sensitive to short-term (2-4 hours) lower power and DR activities are often not disruptive to facility operations; the number of processes is limited and well understood; and past experience with some DR strategies successful in commercial buildings may apply to refrigerated warehouses. This paper presents an overview of the potential for load sheds and shifts from baseline electricity use in response to DR events, along with physical configurations and operating characteristics of refrigerated warehouses. Analysis of data from two case studies and nine facilities in Pacific Gas and Electric territory, confirmed the DR abilities inherent to refrigerated warehouses but showed significant variation across facilities. Further, while load from California's refrigerated warehouses in 2008 was 360 MW with estimated DR potential of 45-90 MW, actual achieved was much less due to low participation. Efforts to overcome barriers to increased participation may include, improved marketing and recruitment of potential DR sites, better alignment and emphasis on financial benefits of participation, and use of Auto-DR to increase consistency of participation.

Goli, Sasank; McKane, Aimee; Olsen, Daniel

2011-06-14T23:59:59.000Z

434

Microbial and objective quality of whole muscle beef cuts packaged in film containing chlorine dioxide  

E-Print Network (OSTI)

The microbial and objective quality of top round steak treated with two deferent prototype chlorine dioxide containing films were evaluated deleing 14 days of refrigerated storage. The films were designed to deliver different dose rates of chlorine dioxide when in contact with tissue. A high dose rate film in combination with dip treatments resulted in a 1.0 log?? reduction of total hemophilic aerobes, total coliforms, and total lactic acid bacteria. However, this same film caused undesirable characteristics including the rapid loss of the red color associated with fresh beef and the development of a green colored pigment. This color change corresponded to a decrease in Hunter a* values. Ascorbic acid treatments slightly inhibited the development of green color after 2 days of storage, but the protective effect was not evident after 6 days of storage and the color remained undesirable. Chlorine dioxide released from the high dose rate film penetrated immediately into the surface of the beef to a depth of 1mm into the surface of the beef after 6 days of storage, and did not penetrate more than 2mm deep after 14 days of storage. The concentration of myoglobin in extracts of the treated samples decreased sharply after 2 days storage, suggesting oxidative degradation and possibly the formation of a compound similar to the green pigment cholemyoglobin. The TBA values of beef treated with the high dose rate film increased during storage but remained blow 1.0. A low chlorine dioxide dose rate film did not produce any microbiological or objective changes in the beef. The dose rate for the high dose rate film was 32ppm/h, as determined by neutron activation analysis. It decreased rapidly to 0ppm/h after 10 days storage and was not constant during the test period. Based on the unacceptable attributes produced by the high dose rate film, it may be better suited for low fat cuts of pork, ash, or chicken that are less susceptible to color changes and quality losses associated with undesirable oxidative changes.

Knight, Timothy David

1999-01-01T23:59:59.000Z

435

Magnetic refrigeration apparatus with belt of ferro or paramagnetic material  

DOE Patents (OSTI)

A magnetic refrigerator operating in the 12 to 77 K range utilizes a belt which carries ferromagnetic or paramagnetic material and which is disposed in a loop which passes through the center of a solenoidal magnet to achieve cooling. The magnetic material carried by the belt, which can be blocks in frames of a linked belt, can be a mixture of substances with different Curie temperatures arranged such that the Curie temperatures progressively increase from one edge of the belt to the other. This magnetic refrigerator can be used to cool and liquefy hydrogen or other fluids.

Barclay, J.A.; Stewart, W.F.; Henke, M.D.; Kalash, K.E.

1986-04-03T23:59:59.000Z

436

The bound-optimal cutting plane method: a new paradigm for cutting ...  

E-Print Network (OSTI)

Oct 24, 2013 ... Page 11 ... single cut because, if cut (c) (resp. cut (d)), is added, the segment CD ? AD (resp. ... Typically, as we will show in Section 5, the bound at which. 11 ..... 1.03 91. 91. 1.65 80. 80. 1.50 48. 48 344.00 huck. 11.00. 9. 9.

437

Influence of External Heat Source on Transcritical CO2 Refrigeration System  

Science Conference Proceedings (OSTI)

Synthetic refrigerants such as CFCs and HCFCs are harmful to the ozone and could cause greenhouse effect. Refrigerant alternatives research is very urgent. CO2 as a natural working fluid has zero ODP and its GWP=1, is receiving more and more attention ... Keywords: Coefficient of Performance, Experimental Investigation, Heat Source, Transcritical CO2 Refrigeration System

Liu Yingfu; Xiao Jian; Jin Guangya

2012-07-01T23:59:59.000Z

438

Proceedings of the 1993 non-fluorocarbon insulation, refrigeration and air conditioning technology workshop  

SciTech Connect

Sessions included: HFC blown polyurethanes, carbon dioxide blown foam and extruded polystyrenes, plastic foam insulations, evacuated panel insulation, refrigeration and air conditioning, absorption and adsorption and stirling cycle refrigeration, innovative cooling technologies, and natural refrigerants. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.

Not Available

1994-09-01T23:59:59.000Z

439

Application Availability of Insulation Heat of the Terrace in a Rebuilt Refrigerator  

E-Print Network (OSTI)

Dealing with the terrace in rebuilt refrigerators influences the performance characteristics, performance safety and construction costs. This paper researches the heat transfer of the terrace of the rebuilt refrigerator by the numerical method, analyzes the temperature distribution of the terrace, and supplies guidance for rebuilding refrigerators.

Qu, C.; Sun, Y.; Chen, Z.

2006-01-01T23:59:59.000Z

440

Cutting tool form compensaton system and method  

DOE Patents (OSTI)

A compensation system for a computer-controlled machining apparatus having a controller and including a cutting tool and a workpiece holder which are movable relative to one another along a preprogrammed path during a machining operation utilizes a camera and a vision computer for gathering information at a preselected stage of a machining operation relating to the actual shape and size of the cutting edge of the cutting tool and for altering the preprogrammed path in accordance with detected variations between the actual size and shape of the cutting edge and an assumed size and shape of the cutting edge. The camera obtains an image of the cutting tool against a background so that the cutting tool and background possess contrasting light intensities, and the vision computer utilizes the contrasting light intensities of the image to locate points therein which correspond to points along the actual cutting edge. Following a series of computations involving the determining of a tool center from the points identified along the tool edge, the results of the computations are fed to the controller where the preprogrammed path is altered as aforedescribed.

Barkman, William E. (Oak Ridge, TN); Babelay, Jr., Edwin F. (Knoxville, TN); Klages, Edward J. (Oak Ridge, TN)

1993-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Corner-cutting mining assembly  

DOE Patents (OSTI)

This invention resulted from a contract with the United States Department of Energy and relates to a mining tool. More particularly, the invention relates to an assembly capable of drilling a hole having a square cross-sectional shape with radiused corners. In mining operations in which conventional auger-type drills are used to form a series of parallel, cylindrical holes in a coal seam, a large amount of coal remains in place in the seam because the shape of the holes leaves thick webs between the holes. A higher percentage of coal can be mined from a seam by a means capable of drilling holes having a substantially square cross section. It is an object of this invention to provide an improved mining apparatus by means of which the amount of coal recovered from a seam deposit can be increased. Another object of the invention is to provide a drilling assembly which cuts corners in a hole having a circular cross section. These objects and other advantages are attained by a preferred embodiment of the invention.

Bradley, J.A.

1981-07-01T23:59:59.000Z

442

Definition: Cuttings Analysis | Open Energy Information  

Open Energy Info (EERE)

Analysis Analysis Jump to: navigation, search Dictionary.png Cuttings Analysis Cuttings are small bits of a rock formation derived from a borehole, the rock chips are carried to the surface by the drilling fluid. As the hole is drilled, cuttings are collected and analyzed to identify lithology and fluids encountered at depth.[1] View on Wikipedia Wikipedia Definition Drill cuttings are the broken bits of solid material removed from a borehole drilled by rotary, percussion, or auger methods. Boreholes drilled in this way include oil or gas wells, water wells, and holes drilled for geotechnical investigations or mineral exploration. The drill cuttings are commonly examined to make a record of the subsurface materials penetrated at various depths. In the oil industry, this is often called a mud log.

443

D0 Silicon Upgrade: Commissioning Test Results for D-Zero's Helium Refrigerator  

Science Conference Proceedings (OSTI)

The test objectives are: (1) Make liquid helium and measure refrigerator capacity; (2) Measure liquid helium dewar heat leak, transfer line heat leak, and liquid nitrogen consumption rates; (3) Operate all cryogenic transfer lines; (4) Get some running time on all components; (5) Debug mechanical components, instrumentation, DMACs user interface, tune loops, and otherwise shake out any problems; (6) Get some operating time in to get familiar with system behavior; (7) Revise and/or improve operating procedures to actual practice; and (8) Identify areas for future improvement. D-Zero's stand alone helium refrigerator (STAR) liquified helium at a rate of 114 L/hr. This is consistent with other STAR installations. Refrigeration capacity was not measured due to lack of a calibrated heat load. Measured heat leaks were within design values. The helium dewar loss was measured at 2 to 4 watts or 9% per day, the solenoid and VLPC helium transfer lines had a heat leak of about 20 watts each. The liquid nitrogen consumption rates of the mobile purifier, STAR, and LN2 subcooler were measured at 20 gph, 20 to 64 gph, and 3 gph respectively. All cryogenic transfer lines including the solenoid and visible light photon counter (VLPC) transfer lines were cooled to their cryogenic operating temperatures. This included independent cooling of nitrogen shields and liquid helium components. No major problems were observed. The system ran quite well. Many problems were identified and corrected as they came up. Areas for improvement were noted and will be implemented in the future. The instrumentation and control system operated commendably during the test. The commissioning test run was a worthwhile and successful venture.

Rucinski, Russ; /Fermilab

1997-06-30T23:59:59.000Z

444

Radial wave thermoacoustic engines: Theory and examples for refrigerators and high?gain narrow?bandwidth photoacoustic spectrometers  

Science Conference Proceedings (OSTI)

A theoretical analysis of radial wave thermoacoustic engines in cylindrical resonators is developed. Impedance and pressure translation equations are presented for open sections of the resonator and for heat exchangers. Coupled first?order differential equations are given for pressure and impedance in the temperature gradient supporting engine section (stack). These quantities are used to calculate heat and work flows and to predict engine performance. Theory and design of a variable quality factor resonator for enhanced photoacoustic spectroscopy are presented. The short stack approximation is developed for the radial geometry and is used along with plane?wave equations to compare refrigerator performance for these two geometries. Results of the comparison are that engines in the plane?wave geometry are better overall refrigerators when maximizing the coefficient of performance and cooling capacity together.

W. Patrick Arnott; Richard Raspet; Hans Moosmller

1996-01-01T23:59:59.000Z

445

Corn stalk orientation effect on mechanical cutting  

SciTech Connect

Research efforts that increase the efficiency of size reduction of biomass can lead to a significant energy saving. This paper deals with the determination of the effect of sample orientation with respect to cutting element and quantify the possible cutting energy reduction, utilising dry corn stalks as the test material (15%e20% wet basis). To evaluate the mechanical cutting characteristics of corn stalks, a Warnere Bratzler device was modified by replacing its blunt edged cutting element with one having a 30_ single bevel sharp knife edge. Cutting force-deformation characteristics obtained with a universal testing machine were analysed to evaluate the orientation effects at perpendicular (90o), inclined (45o), and parallel (0o) orientations on internodes and nodes for cutting force, energy, ultimate stress, and specific energy of corn stalks. The corn stalks cutting force-displacement characteristics were found to differ with orientation, and internode and node material difference. Overall, the peak failure force, and the total cutting energy of internodes and nodes varied significantly (P < 0.05) with stalk cross-sectional area. The specific energy values (total energy per unit cut area) of dry corn stalk internodes ranged from 11.3 to 23.5 kN m_1, and nodes from 8.6 to 14.0 kN m_1. The parallel orientation (along grain) compared to perpendicular (across grain) produced a significant reduction of the cutting stress and the specific energy to one tenth or better for internodes, and to about one-fifth for nodes.

Igathinathane, C. [Mississippi State University (MSU); Womac, A.R. [University of Tennessee; Sokhansanj, Shahabaddine [ORNL

2010-07-01T23:59:59.000Z

446

Design i & ii January 13-June 9  

E-Print Network (OSTI)

Design I 3 CEUs. Explore heating, ventilation, air conditioning and refrigeration in-depth with the firsthVaC-R Systems Design i & ii Tuesdays January 13-June 9 6-9 p.m. advanced Western Cooling p.m. #12;Specifically designed to provide you with the practical skills you need! HVAC-R Systems

Thomases, Becca

447

The Quantum Absorption Refrigerator Amikam Levy and Ronnie Kosloff  

E-Print Network (OSTI)

source to replace mechanical work for driving a heat pump [1]. The first device was developed in 1850 an ab- sorption refrigerator with no moving parts [2]. This idea has been incorporated recently c J h P Tc Th Tw - - - 0 FIG. 1: The quantum trickle: A quantum heat pump des- ignated

Kosloff, Ronnie

448

Microprocessor-based controller for a liquid hydrogen target refrigerator  

DOE Green Energy (OSTI)

A microprocessor-based cryogenic refrigerator controller developed at the Los Alamos Scientific Laboratory provides automatic cooldown and subsequent monitoring of liquid hydrogen targets. The controller performs the initial cooldown of the cryogenic system and provides continuous monitoring of the important system parameters. An alarm is sounded to summon an operator in the event of any parameter exceeding predetermined limits.

Gjovig, A.J.; Little, J.D.; Novak, J.K.

1978-01-01T23:59:59.000Z

449

Optimal Sequencing of Central Refrigeration Equipment in an Industrial Plant  

E-Print Network (OSTI)

A model was developed to find a viable solution to the problem of selecting the optimal sequence of refrigeration equipment (chillers, cooling towers, pumps) to operate in a Central Utility Plant. The optimal equipment sequence is that sequence which has the lowest energy cost to operate at a given plant cooling load and outside air wet bulb temperature. and satisfies all the constraints associated with the refrigeration system. Selection of the optimal equipment sequence is very difficult given the complexity of the refrigeration system and the dynamic nature of the plant cooling load. As a solution a computer program was developed to generate optimal equipment sequences to operate for combinations of a wide range of plant cooling loads and outside air wet bulb temperatures. Analysis of the solution identified the need for a retrofit project to remove "vital" constraints in order to improve the refrigeration system's performance. The solution to the problem was then incorporated in the operating procedures for the Central Utility Plant.

Fiorino, D. P.; Priest, J. W.

1986-01-01T23:59:59.000Z

450

Triple loop heat exchanger for an absorption refrigeration system  

DOE Patents (OSTI)

A triple loop heat exchanger for an absorption refrigeration system is disclosed. The triple loop heat exchanger comprises portions of a strong solution line for conducting relatively hot, strong solution from a generator to a solution heat exchanger of the absorption refrigeration system, conduit means for conducting relatively cool, weak solution from the solution heat exchanger to the generator, and a bypass system for conducting strong solution from the generator around the strong solution line and around the solution heat exchanger to an absorber of the refrigeration system when strong solution builds up in the generator to an undesirable level. The strong solution line and the conduit means are in heat exchange relationship with each other in the triple loop heat exchanger so that, during normal operation of the refrigeration system, heat is exchanged between the relatively hot, strong solution flowing through the strong solution line and the relatively cool, weak solution flowing through the conduit means. Also, the strong solution line and the bypass system are in heat exchange relationship in the triple loop heat exchanger so that if the normal flow path of relatively hot, strong solution flowing from the generator to an absorber is blocked, then this relatively, hot strong solution which will then be flowing through the bypass system in the triple loop heat exchanger, is brought into heat exchange relationship with any strong solution which may have solidified in the strong solution line in the triple loop heat exchanger to thereby aid in desolidifying any such solidified strong solution.

Reimann, Robert C. (Lafayette, NY)

1984-01-01T23:59:59.000Z

451

Laser cutting with chemical reaction assist  

DOE Patents (OSTI)

A method for cutting with a laser beam where an oxygen-hydrocarbon reaction is used to provide auxiliary energy to a metal workpiece to supplement the energy supplied by the laser. Oxygen is supplied to the laser focus point on the workpiece by a nozzle through which the laser beam also passes. A liquid hydrocarbon is supplied by coating the workpiece along the cutting path with the hydrocarbon prior to laser irradiation or by spraying a stream of hydrocarbon through a nozzle aimed at a point on the cutting path which is just ahead of the focus point during irradiation.

Gettemy, Donald J. (Los Alamos, NM)

1992-01-01T23:59:59.000Z

452

Laser cutting with chemical reaction assist  

DOE Patents (OSTI)

This invention is comprised of a method for cutting with a laser beam where an oxygen-hydrocarbon reaction is used to provide auxiliary energy to a metal workpiece to supplement the energy supplied by the laser. Oxygen is supplied to the laser focus point on the workpiece by a nozzle through which the laser beam also passes. A liquid hydrocarbon is supplied by coating the workpiece along the cutting path with the hydrocarbon prior to laser irradiation or by spraying a stream of hydrocarbon through a nozzle aimed at a point on the cutting path which is just ahead of the focus point during irradiation.

Gettemy, D.J.

1991-04-08T23:59:59.000Z

453

FURTHER DEVELOPMENTS IN THE DESIGN OF A FREE-PISTON STIRLING ENGINE  

E-Print Network (OSTI)

NT-87-03-3 FURTHER DEVELOPMENTS IN THE DESIGN OF A FREE-PISTON STIRLING ENGINE HEAT PUMP engine, the MARK I, the FPSE/HP has achieved its two critical milestones of producing 3.0 refrigeration.86 *Refrigeration tons = 12,000 Btu/h (12.66 MJ/h) This paper describes the latest configuration of the FPSE

Oak Ridge National Laboratory

454

*-9~~I ' DESIGN AND LABORATORY TESTING. OFAN UNEQUAL PARALLEL  

E-Print Network (OSTI)

#12;*-9~~I ' DESIGN AND LABORATORY TESTING. OFAN UNEQUAL PARALLEL -t"~~~I~MULTICOMPRESSOR SUPERMARKET REFRIGERATION SYSTEM WITH A MICROPROCESSOR-BASED ELECTRONIC CONTROL SYSTEM William M. Toscano, Ph new highly energy-efficient supermarket systems. A supermarket refrigeration system consisting of: UI

Oak Ridge National Laboratory

455

Design of nanomanufacturing systems  

E-Print Network (OSTI)

Over 100 years of manufacturing knowledge and experience are available to a design engineer when considering the integration of a machine tool enabling macro-scale processes (milling, turning, welding, water-jet cutting) ...

Slocum, Alexander Henry, Jr

2010-01-01T23:59:59.000Z

456

Offshore refrigerated LPG loading/unloading terminal using a CALM buoy  

SciTech Connect

In existing Liquefied Petroleum Gases terminals, the transfer of liquefied gases to the tanker is performed via articulated loading arms or flexible hoses, working under quasistatic conditions. The tanker has to be firmly moored alongside a jetty or a process barge in a protected area (such as a harbour in most cases). This paper gives the main results of the development of an offshore refrigerated LPG (-48/sup 0/C) loading/unloading system, using a CALM buoy and LPG floating hoses working under dynamic conditions. The aim of this new concept is to replace the standard harbour structure for loading/unloading refrigerated LPG and to provide a considerable reduction in investments and a greater flexibility regarding the terminal location. The main components of that terminal have been designed so as to enable the loading of a 75 000 cubic meter LPG carrier in 15 hours. The results of static and dynamic low temperature tests on a LPG swivel joint for CALM buoy and LPG floating hoses show that such a SPM terminal is now a realistic solution.

Bonjour, E.L.; Simon, J.M.

1985-03-01T23:59:59.000Z

457

Fermilab | Take Five for Goal Zero | Gloves | Gunn Cut Leather...  

NLE Websites -- All DOE Office Websites (Extended Search)

Gunn Cut Leather Gloves Gunn Cut Leather Gloves Description Color Finish Uses FNAL Stock Number Cow leather, gunn cut Foam lined Flame resistant cuff Sewn with Kevlar Blue and grey...

458

An Efficient Algorithm for Computing Robust Minimum Capacity st Cuts  

E-Print Network (OSTI)

Apr 3, 2008 ... The Minimum Capacity s-t Cut Problem (Min Cut) is an intensively ... In this paper, we study Min Cut when arc capacities are uncertain but...

459

Fuel Cycle CrossCut Group  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CrossCut Group CrossCut Group 1 NERAC Briefing: Assessment of Dose of Closed vs Open Gen-IV Fuel Cycles David Wade NERAC Meeting September 30, 2002 Fuel Cycle CrossCut Group 2 Public Dose and Worker Dose Comparison of Open vs Closed Fuel Cycles * Gen-IV fuel cycle options are meant to address all stated Gen-IV Goals - Dose to workers and to the public is one of the numerous elements to be evaluated by Gen-IV R&D - The Fuel Cycle Crosscut Group was assigned to take an early look at dose implication tradeoffs of open and closed fuel cycles * FCCG Interpretation of Assignment: - Collect already-existing evaluations and prepare a briefing on what is currently known Fuel Cycle CrossCut Group 3 Approach * Look at Actual Historical Doses Based on Operational Experience - Data compiled by the United Nations Scientific Committee on the Effects of Atomic

460

Hanes Brandes Choloma Cutting CDV Plant Profile  

NLE Websites -- All DOE Office Websites (Extended Search)

Choloma Sportswear Cutting achieved the ENERGY STAR Challenge for Industry by reducing energy usage intensity 22.3% within 2 years of its 2009 baseline year. This resulted in an...

Note: This page contains sample records for the topic "design cut refrigerator" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

LLNL's Saturday lectures explore cutting edge science  

NLE Websites -- All DOE Office Websites (Extended Search)

| NR-13-01-02 LLNL's Saturday lectures explore cutting edge science Linda A Lucchetti, LLNL, (925) 422-5815, lucchetti1@llnl.gov Printer-friendly Lawrence Livermore National...

462

Mechanical Cutting of Irradiated Reactor Internal Components  

SciTech Connect

This paper discusses the use of mechanical cutting methods to volume reduce and package irradiated reactor internal components. The recent completion of the removal of the Reactor Vessel Internals (RVI) from within the Sacramento Municipal Utility District's (SMUD) Rancho Seco Nuclear Power Plant demonstrates that unlike previous methods used for similar projects, mechanical cutting minimizes exposure to workers, costly water cleanup, and excessive secondary waste generation. (authors)

Anderson, M.G.; Fennema, J.A. [MOTA Corporation, West Columbia, SC (United States)

2007-07-01T23:59:59.000Z

463

China Refrigerator Information Label: Specification Development and Potential Impact  

SciTech Connect

In the last five years, China's refrigerator market has grown rapidly, and now urban markets are showing signs of saturation, with ownership rates in urban households reaching 92%. Rural markets continue to grow from a much lower base. As a result of this growth, the Chinese government in 2006 decided to revise the refrigerator standards and its associated efficiency grades for the mandatory energy information label. In the Chinese standards process, the efficiency grades for the information label are tied to the minimum standards. Work on the minimum standards revision began in 2006 and continued through the first half of 2007, when the draft standard was completed under the direction of the China National Institute of Standardization (CNIS). Development of the information label grades required consideration of stakeholder input, continuity with the previous grade classification, ease of implementation, and potential impacts on the market. In this process, CLASP, with the support of METI/IEEJ, collaborated with CNIS to develop the efficiency grades, providing technical input to the process, comment and advice on particular technical issues, and evaluation of the results. After three months of effort and three drafts of the final grade specifications, this work was completed. In addition, in order to effectively evaluate the impact of the label on China's market, CLASP further provided assistance to CNIS to collect data on both the efficiency distribution and product volume distribution of refrigerators on the market. The new information label thresholds to be implemented in 2008 maintain the approach first adopted in 2005 of establishing efficiency levels relative to the minimum standard, but increased the related required efficiency levels by 20% over those established in 2003 and implemented in 2005. The focus of improvement was on the standard refrigerator/freezer (class 5), which constitutes the bulk of the Chinese market. Indeed, the new requirements to achieve grade 1 on the label are now virtually as stringent as those for US Energy Star-qualified or EU A-grade refrigerators. When the energy information label went into effect in March 2005, refrigerator manufacturers were required to display their declared level of efficiency on the label and report it to the China Energy Label Center (CELC), a newly established unit of CNIS responsible for label program management. Because of the visible nature of the label, it was found, through a METI/IEEJ-supported study, that MEPS non-compliance dropped from 4% to zero after the label became mandatory, and that the percentage of higher-grade refrigerators increased. This suggests that the label itself does have potential for shifting the market to higher-efficiency models (Lin 2007). One challenge, however, of assessing this potential impact is the lack of a comprehensive baseline of market efficiency and a program to evaluate the market impact on a yearly basis. As a result, the impact evaluation in this study draws upon the market transformation experience of the related EU energy information label, for which quantitative assessments of its market impact exist. By assuming a parallel process unfolding in China, it is possible to look at the potential impact of the label to 2020. The results of the analysis demonstrates that a robust market transformation program in China focused on the energy information label could save substantial amounts of electricity by 2020, totaling 16.4 TWh annually by that year, compared to a case in which the efficiency distribution of refrigerators was frozen at the 2007 level. Remarkably, the impact of a successful market transformation program with the label would essentially flatten the consumption of electricity for refrigerator use throughout most of the next decade, despite the expectations of continue