Powered by Deep Web Technologies
Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

FPGA Interconnect Delay Fault Testing Erik Chmelar  

E-Print Network [OSTI]

A satisfactory FPGA testing method meets several crite- ria. First, the routing resources must be explicitlyFPGA Interconnect Delay Fault Testing Erik Chmelar Center for Reliable Computing Stanford is a scalable manufactur- ing test method for all SRAM-based FPGAs, able to detect multiple interconnect delay

Stanford University

2

Fault simulation and test generation for small delay faults  

E-Print Network [OSTI]

. ..............................................................................34 Figure 16. A partial path and its esperance........................................................................38 Figure 17. Search space for a path through a particular gate. ............................................39 Figure 18. Path..., etc. [14][15][16][17] Figure 1 shows the SPICE simulation results [12]. Due to process variation, some ICs without defects may also be slower than the specified speed. Delay testing must screen out these devices as well as the defective ones...

Qiu, Wangqi

2007-04-25T23:59:59.000Z

3

A 4000-A HVDC (high-voltage direct-current) circuit breaker with fast fault-clearing capability: Final report  

SciTech Connect (OSTI)

This project is a follow-up of the first development of a 500 kV HVDC airblast circuit breaker (EPRI project 1507-3). The objective was to increase the current interrupting capability from 2200 A to 4000 A and shorten its fault clearing time. A high current 500 kV HVDC circuit breaker has been built using the passive commutation circuit. The breaker is modular in construction and can be designed for a wide variety of system conditions. More than 400 current interruptions were carried out successfully. Tests have shown that this circuit breaker is capable of interrupting more than 4000 A dc. Practical breakers with current interrupting capability of even 5500 A dc could be built. The circuit breaker operation and the fault-clearing process can be materially speeded up if the trip signal is given as soon as the fault is detected and without waiting for the current levels to come down in response to converter control action. The new dc breakers are shown to be capable of withstanding these transient arc currents of 8000 A without affecting its ability to interrupt the direct current that follows the transient. This transient current withstand capability is greater than is likely to occur during dc faults. The fault clearing time of this HVDC circuit breaker is comparable to the fault clearing time of conventional ac breakers for ac faults. The developed HVDC circuit breaker is now commercially available and can be supplied for use in HVDC systems. Its use in such systems is expected to provide flexibility in system design and contribute to system stability. 38 refs., 52 figs., 9 tabs.

Not Available

1988-04-01T23:59:59.000Z

4

Static Variable Ordering in ZBDDs for Path Delay Fault Coverage Calculation  

E-Print Network [OSTI]

to calculate exact PDF coverage nonenumeratively. Each PDF is modeled as a subset of all nets in a circuitStatic Variable Ordering in ZBDDs for Path Delay Fault Coverage Calculation Fatih Kocan, Mehmet Gunes, Mitchell A. Thornton Southern Methodist University, Dallas, Texas, U.S.A. Abstract Zero

Gunes, Mehmet Hadi

5

The Impact of Market Clearing Time and Price Signal Delay on the Stability of Electric Power Markets  

SciTech Connect (OSTI)

We generalize a model, proposed by Alvarado, of the electric power market by including the effects of control and communication. To simulate realistic markets, our model issues control signals only at given times and those signals are delayed during transmission. These two effects transform Alvarado's continuous system into a hybrid system, with consequential effects. The stability analysis of the new system reveals two important properties. First, there is an upper limit on the market clearing time and the delay of the price signal beyond which the system becomes unstable. Second, there is a counter-intuitive relationship between the market clearing time and price signal delay: when the market clearing time is relatively long, delaying the price signal can improve the market's stability while reducing the communication delay can destabilize the market. This counter-intuitive effect shows that the full impact of information technology on power markets can be significant and difficult to anticipate. Therefore, as markets are designed and regulated, careful attention should be paid to the effects of information technology on the market's dynamic behavior.

Nutaro, James J [ORNL; Protopopescu, Vladimir A [ORNL

2009-01-01T23:59:59.000Z

6

Realistic fault modeling and quality test generation of combined delay faults  

E-Print Network [OSTI]

. Summary . . Page . . Vi . Vii . 1X . I 2 . 5 . 5 . 6 . 6 . . . 14 . 14 . 16 . 17 . 18 . 18 . 20 . 20 23 , 33 . 34 36 36 38 . . 44 53 53 2. Future Work . . . . . REFERENCES . VITA Page 54 55 LIST OF FIGURES Fig. 1. Fault... 24 Fig. 10. Fig. 11. Fig. 12. Fig. 13. Fig. 14. Fig. 15. Fig. 16. Fig. 17. Fig. 18. Fig. 19. Fig. 20. Fig. 21. Fig. 22. Fig. 23. Fig. 24. Fig. 25. Path generation algorithm. Example for graph theory . Propagation along longest path...

Thadhlani, Ajaykumar A

2001-01-01T23:59:59.000Z

7

Optimizing Test Pattern Generation Using Top-Off ATPG Methodology for Stuck–AT, Transition and Small Delay Defect Faults  

E-Print Network [OSTI]

................................................................................................................ 8 3.2 AC Scan ................................................................................................................ 9 3.3 AC Scan For Transition Faults - Shortcomings For SDD Detection ................. 12 4. TOP-OFF ATPG... .......................................................................................... 28 5.6 Fortuitous Detections in 1-Detect Transition Pattern Set ................................... 28 5.7 SDD Coverage Of Faults Based On Detections ................................................. 29 6. CONCLUSIONS AND FUTURE WORK...

Gill, Arjun

2013-05-01T23:59:59.000Z

8

A Circuit Level Fault Model for Resistive Opens and Bridges , Xiang Lu+  

E-Print Network [OSTI]

, but the delay calculation was not given. Renovell [7][8] presented detailed electrical behaviors for zero. All possible fault behaviors are illustrated and a general resistive bridge delay calculation method and output behaviors, which is useful in ATPG. In this paper, the delay of a net is defined as the time

Walker, Duncan M. "Hank"

9

CLEAR LAKE BASIN 2000 PROJECT  

SciTech Connect (OSTI)

The following is a final report for the Clear Lake Basin 2000 project. All of the major project construction work was complete and this phase generally included final details and testing. Most of the work was electrical. Erosion control activities were underway to prepare for the rainy season. System testing including pump stations, electrical and computer control systems was conducted. Most of the project focus from November onward was completing punch list items.

LAKE COUNTY SANITATION DISTRICT

2003-03-31T23:59:59.000Z

10

A Novel Low-overhead Delay Testing Technique for Arbitrary Two-Pattern Test Application  

E-Print Network [OSTI]

in manufacturing test to complement stuck-at-fault testing. Design- for-testability techniques, such as enhanced as an alternative to the enhanced scan based delay fault testing method, with significantly less design overhead testing, transition in the state inputs is induced by shifting the scan values by one bit position

Paris-Sud XI, Université de

11

Solar system fault detection  

DOE Patents [OSTI]

A fault detecting apparatus and method are provided for use with an active solar system. The apparatus provides an indication as to whether one or more predetermined faults have occurred in the solar system. The apparatus includes a plurality of sensors, each sensor being used in determining whether a predetermined condition is present. The outputs of the sensors are combined in a pre-established manner in accordance with the kind of predetermined faults to be detected. Indicators communicate with the outputs generated by combining the sensor outputs to give the user of the solar system and the apparatus an indication as to whether a predetermined fault has occurred. Upon detection and indication of any predetermined fault, the user can take appropriate corrective action so that the overall reliability and efficiency of the active solar system are increased.

Farrington, R.B.; Pruett, J.C. Jr.

1984-05-14T23:59:59.000Z

12

Solar system fault detection  

DOE Patents [OSTI]

A fault detecting apparatus and method are provided for use with an active solar system. The apparatus provides an indication as to whether one or more predetermined faults have occurred in the solar system. The apparatus includes a plurality of sensors, each sensor being used in determining whether a predetermined condition is present. The outputs of the sensors are combined in a pre-established manner in accordance with the kind of predetermined faults to be detected. Indicators communicate with the outputs generated by combining the sensor outputs to give the user of the solar system and the apparatus an indication as to whether a predetermined fault has occurred. Upon detection and indication of any predetermined fault, the user can take appropriate corrective action so that the overall reliability and efficiency of the active solar system are increased.

Farrington, Robert B. (Wheatridge, CO); Pruett, Jr., James C. (Lakewood, CO)

1986-01-01T23:59:59.000Z

13

Fault Locating, Prediction and Protection (FLPPS)  

SciTech Connect (OSTI)

One of the main objectives of this DOE-sponsored project was to reduce customer outage time. Fault location, prediction, and protection are the most important aspects of fault management for the reduction of outage time. In the past most of the research and development on power system faults in these areas has focused on transmission systems, and it is not until recently with deregulation and competition that research on power system faults has begun to focus on the unique aspects of distribution systems. This project was planned with three Phases, approximately one year per phase. The first phase of the project involved an assessment of the state-of-the-art in fault location, prediction, and detection as well as the design, lab testing, and field installation of the advanced protection system on the SCE Circuit of the Future located north of San Bernardino, CA. The new feeder automation scheme, with vacuum fault interrupters, will limit the number of customers affected by the fault. Depending on the fault location, the substation breaker might not even trip. Through the use of fast communications (fiber) the fault locations can be determined and the proper fault interrupting switches opened automatically. With knowledge of circuit loadings at the time of the fault, ties to other circuits can be closed automatically to restore all customers except the faulted section. This new automation scheme limits outage time and increases reliability for customers. The second phase of the project involved the selection, modeling, testing and installation of a fault current limiter on the Circuit of the Future. While this project did not pay for the installation and testing of the fault current limiter, it did perform the evaluation of the fault current limiter and its impacts on the protection system of the Circuit of the Future. After investigation of several fault current limiters, the Zenergy superconducting, saturable core fault current limiter was selected for installation. Because of some testing problems with the Zenergy fault current limiter, installation was delayed until early 2009 with it being put into operation on March 6, 2009. A malfunction of the FCL controller caused the DC power supply to the superconducting magnet to be turned off. This inserted the FCL impedance into the circuit while it was in normal operation causing a voltage resonance condition. While these voltages never reached a point where damage would occur on customer equipment, steps were taken to insure this would not happen again. The FCL was reenergized with load on December 18, 2009. A fault was experienced on the circuit with the FCL in operation on January 14, 2010. The FCL operated properly and reduced the fault current by about 8%, what was expected from tests and modeling. As of the end of the project, the FCL was still in operation on the circuit. The third phase of the project involved the exploration of several advanced protection ideas that might be at a state where they could be applied to the Circuit of the Future and elsewhere in the SCE electrical system. Based on the work done as part of the literature review and survey, as well as a number of internal meetings with engineering staff at SCE, a number of ideas were compiled. These ideas were then evaluated for applicability and ability to be applied on the Circuit of the Future in the time remaining for the project. Some of these basic ideas were implemented on the circuit including measurement of power quality before and after the FCL. It was also decided that we would take what was learned as part of the Circuit of the Future work and extend it to the next generation circuit protection for SCE. Also at this time, SCE put in a proposal to the DOE for the Irvine Smart Grid Demonstration using ARRA funding. SCE was successful in obtaining funding for this proposal, so it was felt that exploration of new protection schemes for this Irvine Smart Grid Demonstration would be a good use of the project resources. With this in mind, a protection system that uses fault interrupting switches, hi

Yinger, Robert, J.; Venkata, S., S.; Centeno, Virgilio

2010-09-30T23:59:59.000Z

14

Development of Hydrologic Characterization Technology of Fault Zones  

SciTech Connect (OSTI)

Through an extensive literature survey we find that there is very limited amount of work on fault zone hydrology, particularly in the field using borehole testing. The common elements of a fault include a core, and damage zones. The core usually acts as a barrier to the flow across it, whereas the damage zone controls the flow either parallel to the strike or dip of a fault. In most of cases the damage zone isthe one that is controlling the flow in the fault zone and the surroundings. The permeability of damage zone is in the range of two to three orders of magnitude higher than the protolith. The fault core can have permeability up to seven orders of magnitude lower than the damage zone. The fault types (normal, reverse, and strike-slip) by themselves do not appear to be a clear classifier of the hydrology of fault zones. However, there still remains a possibility that other additional geologic attributes and scaling relationships can be used to predict or bracket the range of hydrologic behavior of fault zones. AMT (Audio frequency Magneto Telluric) and seismic reflection techniques are often used to locate faults. Geochemical signatures and temperature distributions are often used to identify flow domains and/or directions. ALSM (Airborne Laser Swath Mapping) or LIDAR (Light Detection and Ranging) method may prove to be a powerful tool for identifying lineaments in place of the traditional photogrammetry. Nonetheless not much work has been done to characterize the hydrologic properties of faults by directly testing them using pump tests. There are some uncertainties involved in analyzing pressure transients of pump tests: both low permeability and high permeability faults exhibit similar pressure responses. A physically based conceptual and numerical model is presented for simulating fluid and heat flow and solute transport through fractured fault zones using a multiple-continuum medium approach. Data from the Horonobe URL site are analyzed to demonstrate the proposed approach and to examine the flow direction and magnitude on both sides of a suspected fault. We describe a strategy for effective characterization of fault zone hydrology. We recommend conducting a long term pump test followed by a long term buildup test. We do not recommend isolating the borehole into too many intervals. We do recommend ensuring durability and redundancy for long term monitoring.

Karasaki, Kenzi; Onishi, Tiemi; Wu, Yu-Shu

2008-03-31T23:59:59.000Z

15

Assessment 101: The Assessment Cycle, Clear and  

E-Print Network [OSTI]

Assessment 101: The Assessment Cycle, Clear and Simple October 1, 2014 Kellogg West Conference Center, Pomona, CA Resource Binder #12;2014-2015 WASC Senior College and University Commission is pleased expectations. Assessment 101: The Assessment Cycle, Clear and Simple October 1, 2014. Kellogg West, Pomona, CA

Su, Xiao

16

Transition-fault test generation  

E-Print Network [OSTI]

. One way to detect these timing defects is to apply test patterns to the integrated circuit that are generated using the transition-fault model. Unfortunately, industry's current transition-fault test generation schemes produce test sets that are too...

Cobb, Bradley Douglas

2013-02-22T23:59:59.000Z

17

Optimal fault location  

E-Print Network [OSTI]

for the pre-selected time out to pass and initiate reclosing again. If after selected number of attempts of reclosing, fault is still present, breaker lockout is taking place. There will be no more attempts to reclose automatically the breaker again....2: Trip and reclose sequences on a single breaker In the case of breaker lockout the assumption taken by the operators is that fault is permanent. Special order is issued to the maintenance for the breaker to be closed back in 4 again once...

Knezev, Maja

2009-05-15T23:59:59.000Z

18

Optimal fault location  

E-Print Network [OSTI]

for the pre-selected time out to pass and initiate reclosing again. If after selected number of attempts of reclosing, fault is still present, breaker lockout is taking place. There will be no more attempts to reclose automatically the breaker again....2: Trip and reclose sequences on a single breaker In the case of breaker lockout the assumption taken by the operators is that fault is permanent. Special order is issued to the maintenance for the breaker to be closed back in 4 again once...

Knezev, Maja

2008-10-10T23:59:59.000Z

19

Computer hardware fault administration  

DOE Patents [OSTI]

Computer hardware fault administration carried out in a parallel computer, where the parallel computer includes a plurality of compute nodes. The compute nodes are coupled for data communications by at least two independent data communications networks, where each data communications network includes data communications links connected to the compute nodes. Typical embodiments carry out hardware fault administration by identifying a location of a defective link in the first data communications network of the parallel computer and routing communications data around the defective link through the second data communications network of the parallel computer.

Archer, Charles J. (Rochester, MN); Megerian, Mark G. (Rochester, MN); Ratterman, Joseph D. (Rochester, MN); Smith, Brian E. (Rochester, MN)

2010-09-14T23:59:59.000Z

20

Effect of HVDC line faults on transient torsional torques of turbine-generator shafts  

SciTech Connect (OSTI)

This paper investigates the effects of HVdc line faults, line de-energization, and line re-energization on the transient torsional stresses of steam turbine-generator (T-G) units. The studies are conducted on a bipole HVdc system which connects a T-G set to a large ac system. The shaft transient stresses of the T-G set as a result of HVac line fault, fault clearing, and automatic reclosure are also determined when the HVdc transmission system is replaced by an equivalent double-line HVac system. The EMTDC program is used for the simulation studies. The studies conclude that transient shaft stresses as a result of HVdc line fault and its subsequent switching events are (1) significantly less severe than those of HVac faults and subsequent switchings, and (2) not sensitive to the fault location and disturbance duration.

Shi, W. (Xi'an Jiaotong Univ. (China). Dept. of Electrical Engineering); Iravani, M.R. (Univ. of Toronto, Ontario (Canada). Dept. of Electrical Engineering)

1994-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Row fault detection system  

DOE Patents [OSTI]

An apparatus, program product and method check for nodal faults in a row of nodes by causing each node in the row to concurrently communicate with its adjacent neighbor nodes in the row. The communications are analyzed to determine a presence of a faulty node or connection.

Archer, Charles Jens (Rochester, MN); Pinnow, Kurt Walter (Rochester, MN); Ratterman, Joseph D. (Rochester, MN); Smith, Brian Edward (Rochester, MN)

2012-02-07T23:59:59.000Z

22

An algorithm for faulted phase and feeder selection under high impedance fault conditions  

E-Print Network [OSTI]

. Summary SUMMARY AND CONCLUSIONS REFERENCES . SUPPLEMENTAL SOURCES CONSULTED APPENDIX A VITA 57 58 59 59 60 62 68 70 vn LIST OF TABLES Table II. Ihh Comparison of fault-generated phases during arcing fault test Comparison of fault...-generated phases during arcing fault test Comparison of fault-generated phases during arcing fault test activity on activity on activity on faulted and unfaulted Page 45 faulted and unfaulted 46 faulted and unfaulted 47 vu1 LIST OF FIGURES Figure l...

Benner, Carl Lee

1988-01-01T23:59:59.000Z

23

Delay in Atomic Photoionization  

SciTech Connect (OSTI)

We analyze the time delay between emission of photoelectrons from the outer valence ns and np subshells in noble gas atoms following absorption of an attosecond extreme ultraviolet pulse. Various processes such as elastic scattering of the photoelectron on the parent ion and many-electron correlation affect the apparent 'time zero' when the photoelectron leaves the atom. This qualitatively explains the time delay between photoemission from the 2s and 2p subshells of Ne as determined experimentally by attosecond streaking [Science 328, 1658 (2010)]. However, with our extensive numerical modeling, we were only able to account for less than half of the measured time delay of 21{+-}5 as. We argue that the extreme ultraviolet pulse alone cannot produce such a large time delay and it is the streaking IR field that is most likely responsible for this effect.

Kheifets, A. S. [Research School of Physical Sciences, Australian National University, Canberra ACT 0200 (Australia); Kavli Institute for Theoretical Physics, University of California, Santa Barbara, California 93106-4030 (United States); Ivanov, I. A. [Research School of Physical Sciences, Australian National University, Canberra ACT 0200 (Australia)

2010-12-03T23:59:59.000Z

24

Physical Clearing Mechanisms in Power Karla Atkins  

E-Print Network [OSTI]

of energy sector and its impact on generation of electricity, market power, market efficiency, consumption, developed at the Los Alamos National Lab- oratory. Two cities, Portland and Chicago, are used for simulating cities perform very similarly under the different physical clearing mechanisms. I. INTRODUCTION

Marathe, Achla

25

Downhole delay assembly for blasting with series delay  

DOE Patents [OSTI]

A downhole delay assembly is provided which can be placed into a blasthole for initiation of explosive in the blasthole. The downhole delay assembly includes at least two detonating time delay devices in series in order to effect a time delay of longer than about 200 milliseconds in a round of explosions. The downhole delay assembly provides a protective housing to prevent detonation of explosive in the blasthole in response to the detonation of the first detonating time delay device. There is further provided a connection between the first and second time delay devices. The connection is responsive to the detonation of the first detonating time delay device and initiates the second detonating time delay device. A plurality of such downhole delay assemblies are placed downhole in unfragmented formation and are initiated simultaneously for providing a round of explosive expansions. The explosive expansions can be used to form an in situ oil shale retort containing a fragmented permeable mass of formation particles.

Ricketts, Thomas E. (Grand Junction, CO)

1982-01-01T23:59:59.000Z

26

ClearWorld Now | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartmentAUDITOhioOglesby,Sullivan, MissouriWebsterElectric CoopClearWorld Now Jump to:

27

Fault current limiter  

DOE Patents [OSTI]

A fault current limiter (FCL) includes a series of high permeability posts for collectively define a core for the FCL. A DC coil, for the purposes of saturating a portion of the high permeability posts, surrounds the complete structure outside of an enclosure in the form of a vessel. The vessel contains a dielectric insulation medium. AC coils, for transporting AC current, are wound on insulating formers and electrically interconnected to each other in a manner such that the senses of the magnetic field produced by each AC coil in the corresponding high permeability core are opposing. There are insulation barriers between phases to improve dielectric withstand properties of the dielectric medium.

Darmann, Francis Anthony

2013-10-08T23:59:59.000Z

28

ClearPath | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160Benin:EnergyWisconsin: Energy Resources JumpSouthSolarClearPath Jump to: navigation,

29

ClearSpot Energy | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address: 160Benin:EnergyWisconsin: Energy Resources JumpSouthSolarClearPath Jump to:

30

Template:Clear | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:Seadov Pty LtdSteen,Ltd Jump to:Taos County,TeesAtlasTabs Jump to: navigation,Lease'Clear

31

Colorado Regional Faults  

SciTech Connect (OSTI)

Citation Information: Originator: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Originator: Colorado Geological Survey (CGS) Publication Date: 2012 Title: Regional Faults Edition: First Publication Information: Publication Place: Earth Science & Observation Center, Cooperative Institute for Research in Environmental Science, University of Colorado, Boulder Publisher: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Description: This layer contains the regional faults of Colorado Spatial Domain: Extent: Top: 4543192.100000 m Left: 144385.020000 m Right: 754585.020000 m Bottom: 4094592.100000 m Contact Information: Contact Organization: Earth Science &Observation Center (ESOC), CIRES, University of Colorado at Boulder Contact Person: Khalid Hussein Address: CIRES, Ekeley Building Earth Science & Observation Center (ESOC) 216 UCB City: Boulder State: CO Postal Code: 80309-0216 Country: USA Contact Telephone: 303-492-6782 Spatial Reference Information: Coordinate System: Universal Transverse Mercator (UTM) WGS’1984 Zone 13N False Easting: 500000.00000000 False Northing: 0.00000000 Central Meridian: -105.00000000 Scale Factor: 0.99960000 Latitude of Origin: 0.00000000 Linear Unit: Meter Datum: World Geodetic System 1984 (WGS ’984) Prime Meridian: Greenwich Angular Unit: Degree Digital Form: Format Name: Shape file

Hussein, Khalid

2012-02-01T23:59:59.000Z

32

Observer-based fault detection for nuclear reactors  

E-Print Network [OSTI]

This is a study of fault detection for nuclear reactor systems. Basic concepts are derived from fundamental theories on system observers. Different types of fault- actuator fault, sensor fault, and system dynamics fault ...

Li, Qing, 1972-

2001-01-01T23:59:59.000Z

33

Synchronized sampling improves fault location  

SciTech Connect (OSTI)

Transmission line faults must be located accurately to allow maintenance crews to arrive at the scene and repair the faulted section as soon as possible. Rugged terrain and geographical layout cause some sections of power transmission lines to be difficult to reach. In the past, a variety of fault location algorithms were introduced as either an add-on feature in protective relays or stand-alone implementation in fault locators. In both cases, the measurements of current and voltages were taken at one terminal of a transmission line only. Under such conditions, it may become difficult to determine the fault location accurately, since data from other transmission line ends are required for more precise computations. In the absence of data from the other end, existing algorithms have accuracy problems under several circumstances, such as varying switching and loading conditions, fault infeed from the other end, and random value of fault resistance. Most of the one-end algorithms were based on estimation of voltage and current phasors. The need to estimate phasors introduces additional difficulty in high-speed tripping situations where the algorithms may not be fast enough in determining fault location accurately before the current signals disappear due to the relay operation and breaker opening. This article introduces a unique concept of high-speed fault location that can be implemented either as a simple add-on to the digital fault recorders (DFRs) or as a stand-alone new relaying function. This advanced concept is based on the use of voltage and current samples that are synchronously taken at both ends of a transmission line. This sampling technique can be made readily available in some new DFR designs incorporating receivers for accurate sampling clock synchronization using the satellite Global Positioning System (GPS).

Kezunovic, M. [Texas A and M Univ., College Station, TX (United States)] [Texas A and M Univ., College Station, TX (United States); Perunicic, B. [Lamar Univ., Beaumont, TX (United States)] [Lamar Univ., Beaumont, TX (United States)

1995-04-01T23:59:59.000Z

34

-delayed proton emission branches in 43Cr  

SciTech Connect (OSTI)

The + decay of very neutron-deficient 43Cr was studied by means of an imaging time projection chamber that allowed recording tracks of charged particles. Events of -delayed emission of one, two, and three protons were clearly identified. The absolute branching ratios for these channels were determined to be (81 4)%, (7.1 0.4)%, and (0.08 0.03)%, respectively. 43Cr is thus established as the second case in which the -3p decay occurs. Although the feeding to the proton-bound states in 43V is expected to be negligible, the large branching ratio of (12 4)% for decays without proton emission is found.

Pomorski, M. [University of Warsaw; Miernik, K. [University of Warsaw; Dominik, W. [University of Warsaw; Janas, Z. [University of Warsaw; Pfutzner, M. [University of Warsaw; Bingham, C. R. [University of Tennessee, Knoxville (UTK); Czyrkowski, H. [University of Warsaw; Cwiok, Mikolaj [Warsaw University; Darby, Iain [University of Tennessee, Knoxville (UTK); Dabrowski, Ryszard [Warsaw University; Ginter, T. N. [Michigan State University, East Lansing; Grzywacz, Robert Kazimierz [ORNL; Karny, M. [University of Warsaw; Korgul, A. [University of Warsaw; Kusmierz, W. [University of Warsaw; Liddick, Sean [University of Tennessee, Knoxville (UTK); Rajabali, M. M. [University of Tennessee, Knoxville (UTK); Rykaczewski, Krzysztof Piotr [ORNL; Stolz, A. [Michigan State University, East Lansing

2011-01-01T23:59:59.000Z

35

Congestion delays at hub airports  

E-Print Network [OSTI]

A deterministic model was developed to study the effects of inefficient scheduling on flight delays at hub airports. The model bases the delay calculation on published schedule data and on user-defined airport capacities. ...

St. George, Martin J.

1986-01-01T23:59:59.000Z

36

Arc fault detection system  

DOE Patents [OSTI]

An arc fault detection system for use on ungrounded or high-resistance-grounded power distribution systems is provided which can be retrofitted outside electrical switchboard circuits having limited space constraints. The system includes a differential current relay that senses a current differential between current flowing from secondary windings located in a current transformer coupled to a power supply side of a switchboard, and a total current induced in secondary windings coupled to a load side of the switchboard. When such a current differential is experienced, a current travels through a operating coil of the differential current relay, which in turn opens an upstream circuit breaker located between the switchboard and a power supply to remove the supply of power to the switchboard.

Jha, Kamal N. (Bethel Park, PA)

1999-01-01T23:59:59.000Z

37

Arc fault detection system  

DOE Patents [OSTI]

An arc fault detection system for use on ungrounded or high-resistance-grounded power distribution systems is provided which can be retrofitted outside electrical switchboard circuits having limited space constraints. The system includes a differential current relay that senses a current differential between current flowing from secondary windings located in a current transformer coupled to a power supply side of a switchboard, and a total current induced in secondary windings coupled to a load side of the switchboard. When such a current differential is experienced, a current travels through a operating coil of the differential current relay, which in turn opens an upstream circuit breaker located between the switchboard and a power supply to remove the supply of power to the switchboard. 1 fig.

Jha, K.N.

1999-05-18T23:59:59.000Z

38

Standard cosmology delayed  

SciTech Connect (OSTI)

The introduction of a delay in the Friedmann equation of cosmological evolution is shown to result in the very early universe undergoing the necessary accelerated expansion in the usual radiation (or matter) dominated phase. Occurring even without a violation of the strong energy condition, this expansion slows down naturally to go over to the decelerated phase, namely the standard Hubble expansion. This may obviate the need for a scalar field driven inflationary epoch.

Choudhury, Debajyoti [Department of Physics and Astrophysics, University of Delhi, Delhi 110007 (India); Ghoshal, Debashis [School of Physical Sciences, Jawaharlal Nehru University, New Delhi 110067 (India); Sen, Anjan Ananda, E-mail: debajyoti.choudhury@gmail.com, E-mail: dghoshal@mail.jnu.ac.in, E-mail: anjan.ctp@jmi.ac.in [Centre for Theoretical Physics, Jamia Millia Islamia, New Delhi 110025 (India)

2012-02-01T23:59:59.000Z

39

Standard Cosmology Delayed  

E-Print Network [OSTI]

The introduction of a delay in the Friedmann equation of cosmological evolution is shown to result in the very early universe undergoing the necessary accelerated expansion in the usual radiation (or matter) dominated phase. Occurring even without a violation of the strong energy condition, this expansion slows down naturally to go over to the decelerated phase, namely the standard Hubble expansion. This may obviate the need for a scalar field driven inflationary epoch.

Debajyoti Choudhury; Debashis Ghoshal; Anjan Ananda Sen

2012-02-06T23:59:59.000Z

40

Standard Cosmology Delayed  

E-Print Network [OSTI]

The introduction of a delay in the Friedmann equation of cosmological evolution is shown to result in the very early universe undergoing the necessary accelerated expansion in the usual radiation (or matter) dominated phase. Occurring even without a violation of the strong energy condition, this expansion slows down naturally to go over to the decelerated phase, namely the standard Hubble expansion. This may obviate the need for a scalar field driven inflationary epoch.

Choudhury, Debajyoti; Sen, Anjan Ananda

2011-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Programmable Differential Delay Circuit With Fine Delay Adjustment  

DOE Patents [OSTI]

Circuitry that provides additional delay to early arriving signals such that all data signals arrive at a receiving latch with same path delay. The delay of a forwarded clock reference is also controlled such that the capturing clock edge will be optimally positioned near quadrature (depending on latch setup/hold requirements). The circuitry continuously adapts to data and clock path delay changes and digital filtering of phase measurements reduce errors brought on by jittering data edges. The circuitry utilizes only the minimum amount of delay necessary to achieve objective thereby limiting any unintended jitter. Particularly, this programmable differential delay circuit with fine delay adjustment is designed to allow the skew between ASICS to be minimized. This includes skew between data bits, between data bits and clocks as well as minimizing the overall skew in a channel between ASICS.

DeRyckere, John F. (Eau Claire, WI); Jenkins, Philip Nord (Eau Claire, WI); Cornett, Frank Nolan (Chippewa Falls, WI)

2002-07-09T23:59:59.000Z

42

Hot Pot Detail - Evidence of Quaternary Faulting  

SciTech Connect (OSTI)

Compilation of published data, field observations and photo interpretation relevant to Quaternary faulting at Hot Pot.

Lane, Michael

2013-06-27T23:59:59.000Z

43

Hot Pot Detail - Evidence of Quaternary Faulting  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Compilation of published data, field observations and photo interpretation relevant to Quaternary faulting at Hot Pot.

Lane, Michael

44

Modeling delay in genetic networks: From delay birth-death processes to delay stochastic differential equations  

E-Print Network [OSTI]

genetic circuits17­26 ; the infusion of delay dramatically enhances the stability of such circuits27

Ott, William

45

Setting clear expectations for safety basis development  

SciTech Connect (OSTI)

DOE-RL has set clear expectations for a cost-effective approach for achieving compliance with the Nuclear Safety Management requirements (10 CFR 830, Nuclear Safety Rule) which will ensure long-term benefit to Hanford. To facilitate implementation of these expectations, tools were developed to streamline and standardize safety analysis and safety document development resulting in a shorter and more predictable DOE approval cycle. A Hanford Safety Analysis and Risk Assessment Handbook (SARAH) was issued to standardized methodologies for development of safety analyses. A Microsoft Excel spreadsheet (RADIDOSE) was issued for the evaluation of radiological consequences for accident scenarios often postulated for Hanford. A standard Site Documented Safety Analysis (DSA) detailing the safety management programs was issued for use as a means of compliance with a majority of 3009 Standard chapters. An in-process review was developed between DOE and the Contractor to facilitate DOE approval and provide early course correction. As a result of setting expectations and providing safety analysis tools, the four Hanford Site waste management nuclear facilities were able to integrate into one Master Waste Management Documented Safety Analysis (WM-DSA).

MORENO, M.R.

2003-05-03T23:59:59.000Z

46

Vehicle barrier with access delay  

DOE Patents [OSTI]

An access delay vehicle barrier for stopping unauthorized entry into secure areas by a vehicle ramming attack includes access delay features for preventing and/or delaying an adversary from defeating or compromising the barrier. A horizontally deployed barrier member can include an exterior steel casing, an interior steel reinforcing member and access delay members disposed within the casing and between the casing and the interior reinforcing member. Access delay members can include wooden structural lumber, concrete and/or polymeric members that in combination with the exterior casing and interior reinforcing member act cooperatively to impair an adversarial attach by thermal, mechanical and/or explosive tools.

Swahlan, David J; Wilke, Jason

2013-09-03T23:59:59.000Z

47

Fault-tolerant rotary actuator  

DOE Patents [OSTI]

A fault-tolerant actuator module, in a single containment shell, containing two actuator subsystems that are either asymmetrically or symmetrically laid out is provided. Fault tolerance in the actuators of the present invention is achieved by the employment of dual sets of equal resources. Dual resources are integrated into single modules, with each having the external appearance and functionality of a single set of resources.

Tesar, Delbert

2006-10-17T23:59:59.000Z

48

Passive fault current limiting device  

DOE Patents [OSTI]

A passive current limiting device and isolator is particularly adapted for use at high power levels for limiting excessive currents in a circuit in a fault condition such as an electrical short. The current limiting device comprises a magnetic core wound with two magnetically opposed, parallel connected coils of copper, a high temperature superconductor or other electrically conducting material, and a fault element connected in series with one of the coils. Under normal operating conditions, the magnetic flux density produced by the two coils cancel each other. Under a fault condition, the fault element is triggered to cause an imbalance in the magnetic flux density between the two coils which results in an increase in the impedance in the coils. While the fault element may be a separate current limiter, switch, fuse, bimetal strip or the like, it preferably is a superconductor current limiter conducting one-half of the current load compared to the same limiter wired to carry the total current of the circuit. The major voltage during a fault condition is in the coils wound on the common core in a preferred embodiment. 6 figs.

Evans, D.J.; Cha, Y.S.

1999-04-06T23:59:59.000Z

49

Internal structure of the Kern Canyon Fault, California: a deeply exhumed strike-slip fault  

E-Print Network [OSTI]

Deformation and mineral alteration adjacent to a 2 km long segment of the Kern Canyon fault near Lake Isabella, California are studied to characterize the internal structure of the fault zone and to understand the development of fault structure...

Neal, Leslie Ann

2002-01-01T23:59:59.000Z

50

Development of secondary faults between en echelon, oblique-slip faults: examples from basement controlled, small-fault systems in the Llano Uplift of central Texas  

E-Print Network [OSTI]

between and oriented oblique to the bounding faults. With increasing displacement on the bounding faults, the system of secondary faults evolves from an Elementary to a Compound, to an Advanced geometry, which includes the formation of secondary... to the primary faults. Synthetic faults form interior to and ahead of the bounding faults, increasing the effective overlap. Displacements on antithetic faults are directly related to changes in displacement on associated bounding faults. Additionally...

Hedgcoxe, Howard Reiffert

2012-06-07T23:59:59.000Z

51

Development of Characterization Technology for Fault Zone Hydrology  

E-Print Network [OSTI]

TECHNOLOGY FOR FAULT ZONE HYDROLOGY Kenzi Karasaki Lawrencefor characterizing the hydrology of fault zones, recognizingstructure of faults to hydrology, that it still may be

Karasaki, Kenzi

2010-01-01T23:59:59.000Z

52

Modeling delay in genetic networks: From delay birth-death processes to delay stochastic differential equations  

SciTech Connect (OSTI)

Delay is an important and ubiquitous aspect of many biochemical processes. For example, delay plays a central role in the dynamics of genetic regulatory networks as it stems from the sequential assembly of first mRNA and then protein. Genetic regulatory networks are therefore frequently modeled as stochastic birth-death processes with delay. Here, we examine the relationship between delay birth-death processes and their appropriate approximating delay chemical Langevin equations. We prove a quantitative bound on the error between the pathwise realizations of these two processes. Our results hold for both fixed delay and distributed delay. Simulations demonstrate that the delay chemical Langevin approximation is accurate even at moderate system sizes. It captures dynamical features such as the oscillatory behavior in negative feedback circuits, cross-correlations between nodes in a network, and spatial and temporal information in two commonly studied motifs of metastability in biochemical systems. Overall, these results provide a foundation for using delay stochastic differential equations to approximate the dynamics of birth-death processes with delay.

Gupta, Chinmaya; López, José Manuel; Azencott, Robert; Ott, William [Department of Mathematics, University of Houston, Houston, Texas 77004 (United States); Bennett, Matthew R. [Department of Biochemistry and Cell Biology, Rice University, Houston, Texas 77204, USA and Institute of Biosciences and Bioengineering, Rice University, Houston, Texas 77005 (United States); Josi?, Krešimir [Department of Mathematics, University of Houston, Houston, Texas 77004 (United States); Department of Biology and Biochemistry, University of Houston, Houston, Texas 77204 (United States)

2014-05-28T23:59:59.000Z

53

Automated Fault Location In Smart Distribution Systems  

E-Print Network [OSTI]

of utilizing a suitable fault location method. As distribution systems are gradually evolving into smart distribution systems, application of more accurate fault location methods based on gathered data from various Intelligent Electronic Devices (IEDs...

Lotfifard, Saeed

2012-10-19T23:59:59.000Z

54

LMFBR operational and experimental local-fault experience, primarily with oxide fuel elements  

SciTech Connect (OSTI)

Case-by-case reviews of selective world experience with severe local faults, particularly fuel failure and fuel degradation, are reviewed for two sodium-cooled thermal reactors, several LMFBRs, and LMFBR-fuels experiments. The review summarizes fuel-failure frequency and illustrates the results of the most damaging LMFBR local-fault experiences of the last 20 years beginning with BR-5 and including DFR, BOR-60, BR2's MFBS- and Mol-loops experiments, Fermi, KNK, Rapsodie, EBR-II, and TREAT-D2. Local-fault accommodation is demonstrated and a need to more thoroughly investigate delayed-neutron and gaseous-fission-product signals is highlighted in view of uranate formation, observed blockages, and slow fuel-element failure-propagation.

Warinner, D.K.

1980-01-01T23:59:59.000Z

55

LMFBR operational and experimental in-core local-fault experience, primarily with oxide fuel elements  

SciTech Connect (OSTI)

Case-by-case reviews of selective world experience with severe local faults, particularly fuel failure and fuel degradation, are reviewed for two sodium-cooled thermal reactors, several LMFBRs, and LMFBR-fuels experiments. The review summarizes fuel-failure frequency and illustrates the results of the most damaging LMFBR local-fault experiences of the last 20 years beginning with BR-5 and including DFR, BOR-60, BR2's MFBS-and Mol-loops experiments, Fermi, KNK, Rapsodie, EBR-II, and TREAT-D2. Local-fault accommodation is demonstrated and a need to more thoroughly investigate delayed-neutron and gaseous-fission-product signals is highlighted in view of uranate formation, observed blockages, and slow fuel-element failure-propagation.

Warinner, D.K.

1980-08-10T23:59:59.000Z

56

A Rectilinear-Monotone Polygonal Fault Block Model for Fault-Tolerant Minimal Routing  

E-Print Network [OSTI]

]. In rectangular model, all faulty nodes are grouped in dis- jointed, rectangular areas, called fault blocksA Rectilinear-Monotone Polygonal Fault Block Model for Fault-Tolerant Minimal Routing in Mesh Dajin Wang, Member, IEEE Abstract--We propose a new fault block model, Minimal-Connected-Component (MCC

Wang, Dajin

57

High temperature superconducting fault current limiter  

DOE Patents [OSTI]

A fault current limiter for an electrical circuit is disclosed. The fault current limiter includes a high temperature superconductor in the electrical circuit. The high temperature superconductor is cooled below its critical temperature to maintain the superconducting electrical properties during operation as the fault current limiter. 15 figs.

Hull, J.R.

1997-02-04T23:59:59.000Z

58

Software Fault Diagnosis Peter Zoeteweij  

E-Print Network [OSTI]

Lab, Faculty of Electrical Engineering, Mathematics, and Computer Science, Delft University-to-day basis is constantly growing. Combined with a practically constant rate of faults per line of code in the software development cycle, which aim at exposing such discrepancies. In this context, automated diagnosis

Zoeteweij, Peter

59

ClearFuels-Rentech Pilot-Scale Biorefinery  

Broader source: Energy.gov [DOE]

The ClearFuels-Rentech pilot-scale biorefinery will use Fisher-Tropsch gas-to-liquids technology to create diesel and jet fuel.

60

Clearing the Air: "AIR" Training Session Wednesday, December 18  

E-Print Network [OSTI]

Clearing the Air: "AIR" Training Session Wednesday, December 18 12 p.m. ­ 1:00 p.m. Human Resources/Tobacco- Free! Join us for an interactive session and learn more about "AIR" (Approach, Inform, Refer, and safe campus environment. Visit Clearing the Air website (http://tobaccofree.ucr.edu/) for more

Reed, Christopher A.

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Satellite measurements of the clear-sky greenhouse effect from  

E-Print Network [OSTI]

LETTERS Satellite measurements of the clear-sky greenhouse effect from tropospheric ozone HELEN M of 0.48±0.14 W m-2 between 45 S and 45 N. This estimate of the clear-sky greenhouse effect from

Waliser, Duane E.

62

The effects of lithology and initial fault angle in physical models of fault-propagation folds  

E-Print Network [OSTI]

Experimentally deformed physical rock models are used to examine the effects of changing mechanical stratigraphy and initial fault angle on the development of fault-propagation folds over a flat-ramp-flat thrust geometry. This study also...

McLain, Christopher Thomas

2001-01-01T23:59:59.000Z

63

A fault location approach for fuzzy fault section estimation on radial distribution feeders  

E-Print Network [OSTI]

measured at feeder substations and the fault distance algorithm was tested using data obtained by staging faults on a model of an overhead feeder using EMTP/ATP simulation. The results obtained from the tests were promising. A simple illustration...

Andoh, Kwame Sarpong

2000-01-01T23:59:59.000Z

64

Collateral damage: Evolution with displacement of fracture distribution and secondary fault strands in fault damage zones  

E-Print Network [OSTI]

8 m fault 14 m fault Lonewolf Wadi Araba Carboneras Caletasiltstone, conglomerate Wadi As Sir Limestone gneiss schistFaulkner et al. , 2003], and Wadi Araba [Du Bernard et al. ,

Savage, Heather M.; Brodsky, Emily E.

2011-01-01T23:59:59.000Z

65

The detection of high impedance faults using random fault behavior  

E-Print Network [OSTI]

the energy 120 100 80 O& 60 C Lu 40 20 100 200 300 400 500 600 700 800 900 1000 1100 Cycle Number Figure 1. Typical lugh frequency energy per cycle for an arcing fault. 23 . 055 . 050 . 025 Ol . 020 . 01 5 . 010 . 005 25 50 75 100 125... 150 175 200 225 250 275 500 Cycle Number Figure 2. Typical high frequency energy per cycle for a normal system. 24 3 Vl c uj 2 100 200 300 400 500 600 700 800 900 '1000 1100 Cycle Number Figure 3. Typical high frequency energy per cycle for a...

Carswell, Patrick Wayne

1988-01-01T23:59:59.000Z

66

Detachment Faulting & Geothermal Resources - Pearl Hot Spring...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Faulting & Geothermal Resources - Pearl Hot Spring, NV Conducting a 3D Converted Shear Wave Project to Reduce Exploration Risk at Wister, CA Crump Geyser: High Precision...

67

UWB delay and multiply receiver  

DOE Patents [OSTI]

An ultra-wideband (UWB) delay and multiply receiver is formed of a receive antenna; a variable gain attenuator connected to the receive antenna; a signal splitter connected to the variable gain attenuator; a multiplier having one input connected to an undelayed signal from the signal splitter and another input connected to a delayed signal from the signal splitter, the delay between the splitter signals being equal to the spacing between pulses from a transmitter whose pulses are being received by the receive antenna; a peak detection circuit connected to the output of the multiplier and connected to the variable gain attenuator to control the variable gain attenuator to maintain a constant amplitude output from the multiplier; and a digital output circuit connected to the output of the multiplier.

Dallum, Gregory E.; Pratt, Garth C.; Haugen, Peter C.; Romero, Carlos E.

2013-09-10T23:59:59.000Z

68

Research on Fault Analysis and Fault-Tolerant Control of EV/HEV Powertrain  

E-Print Network [OSTI]

presents research works in the topics of fault analysis and fault tolerant control of an electric vehicle mechanism (transition strategy) at sensor fault occurrence. Index Terms--Electric vehicle, induction motor-tolerant AC motor drives in industrial applications [9-10- 41]. II. ELECTRIC VEHICLE POWERTRAIN COMPONENTS

Brest, Université de

69

Towards Fault-Tolerant Digital Microfluidic Lab-on-Chip: Defects, Fault Modeling, Testing, and Reconfiguration  

E-Print Network [OSTI]

Towards Fault-Tolerant Digital Microfluidic Lab-on-Chip: Defects, Fault Modeling, Testing, NC 27708, USA Abstract Dependability is an important attribute for microfluidic lab-on-chip devices microfluidic lab-on-chip systems. Defects are related to logical fault models that can be viewed not only

Chakrabarty, Krishnendu

70

Contribution of Identified Active Faults to Near Fault Seismic Hazard in the Flinders Ranges  

E-Print Network [OSTI]

Somerville1 , Peggy Quijada1 , Hong Kie Thio1 , Mike Sandiford2 and Mark Quigley2 1. URS Corporation estimates of fault slip rate from Quigley et al. (2006) to quantify the seismic activity rate on the faults of these models was used in conjunction with the active fault model. Quigley et al. (2006) identified a system

Sandiford, Mike

71

Earthquake behavior and structure of oceanic transform faults  

E-Print Network [OSTI]

Oceanic transform faults that accommodate strain at mid-ocean ridge offsets represent a unique environment for studying fault mechanics. Here, I use seismic observations and models to explore how fault structure affects ...

Roland, Emily Carlson

2012-01-01T23:59:59.000Z

72

Low-cost motor drive embedded fault diagnosis systems  

E-Print Network [OSTI]

Electric motors are used widely in industrial manufacturing plants. Bearing faults, insulation faults, and rotor faults are the major causes of electric motor failures. Based on the line current analysis, this dissertation mainly deals with the low...

Akin, Bilal

2009-05-15T23:59:59.000Z

73

Global horizontal irradiance clear sky models : implementation and analysis.  

SciTech Connect (OSTI)

Clear sky models estimate the terrestrial solar radiation under a cloudless sky as a function of the solar elevation angle, site altitude, aerosol concentration, water vapor, and various atmospheric conditions. This report provides an overview of a number of global horizontal irradiance (GHI) clear sky models from very simple to complex. Validation of clear-sky models requires comparison of model results to measured irradiance during clear-sky periods. To facilitate validation, we present a new algorithm for automatically identifying clear-sky periods in a time series of GHI measurements. We evaluate the performance of selected clear-sky models using measured data from 30 different sites, totaling about 300 site-years of data. We analyze the variation of these errors across time and location. In terms of error averaged over all locations and times, we found that complex models that correctly account for all the atmospheric parameters are slightly more accurate than other models, but, primarily at low elevations, comparable accuracy can be obtained from some simpler models. However, simpler models often exhibit errors that vary with time of day and season, whereas the errors for complex models vary less over time.

Stein, Joshua S.; Hansen, Clifford W.; Reno, Matthew J.

2012-03-01T23:59:59.000Z

74

active fault segments: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Fault activation Kuzmanov, Georgi 140 Early stage evolution of growth faults: 3D seismic insights from the Levant Basin, Eastern Mediterranean Materials Science Websites...

75

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems  

E-Print Network [OSTI]

in Fault Diagnostics for HVAC Systems Massieh Najafi 1 ,tools for determining HVAC diagnostics, methods todetect faults in HVAC systems are still generally

Najafi, Massieh

2010-01-01T23:59:59.000Z

76

Sensor Fault Diagnosis Using Principal Component Analysis  

E-Print Network [OSTI]

The purpose of this research is to address the problem of fault diagnosis of sensors which measure a set of direct redundant variables. This study proposes: 1. A method for linear senor fault diagnosis 2. An analysis of isolability and detectability...

Sharifi, Mahmoudreza

2010-07-14T23:59:59.000Z

77

Physiochemical Evidence of Faulting Processes and Modeling of Fluid in Evolving Fault Systems in Southern California  

SciTech Connect (OSTI)

Our study targets recent (Plio-Pleistocene) faults and young (Tertiary) petroleum fields in southern California. Faults include the Refugio Fault in the Transverse Ranges, the Ellwood Fault in the Santa Barbara Channel, and most recently the Newport- Inglewood in the Los Angeles Basin. Subsurface core and tubing scale samples, outcrop samples, well logs, reservoir properties, pore pressures, fluid compositions, and published structural-seismic sections have been used to characterize the tectonic/diagenetic history of the faults. As part of the effort to understand the diagenetic processes within these fault zones, we have studied analogous processes of rapid carbonate precipitation (scaling) in petroleum reservoir tubing and manmade tunnels. From this, we have identified geochemical signatures in carbonate that characterize rapid CO2 degassing. These data provide constraints for finite element models that predict fluid pressures, multiphase flow patterns, rates and patterns of deformation, subsurface temperatures and heat flow, and geochemistry associated with large fault systems.

Boles, James [Professor

2013-05-24T23:59:59.000Z

78

Self-triggering superconducting fault current limiter  

DOE Patents [OSTI]

A modular and scaleable Matrix Fault Current Limiter (MFCL) that functions as a "variable impedance" device in an electric power network, using components made of superconducting and non-superconducting electrically conductive materials. The matrix fault current limiter comprises a fault current limiter module that includes a superconductor which is electrically coupled in parallel with a trigger coil, wherein the trigger coil is magnetically coupled to the superconductor. The current surge doing a fault within the electrical power network will cause the superconductor to transition to its resistive state and also generate a uniform magnetic field in the trigger coil and simultaneously limit the voltage developed across the superconductor. This results in fast and uniform quenching of the superconductors, significantly reduces the burnout risk associated with non-uniformity often existing within the volume of superconductor materials. The fault current limiter modules may be electrically coupled together to form various "n" (rows).times."m" (columns) matrix configurations.

Yuan, Xing (Albany, NY); Tekletsadik, Kasegn (Rexford, NY)

2008-10-21T23:59:59.000Z

79

CLEAR (Calculates Logical Evacuation And Response): A Generic Transportation Network Model for the Calculation of Evacuation Time Estimates  

SciTech Connect (OSTI)

This paper describes the methodology and application of the computer model CLEAR (Calculates Logical Evacuation And Response) which estimates the time required for a specific population density and distribution to evacuate an area using a specific transportation network. The CLEAR model simulates vehicle departure and movement on a transportation network according to the conditions and consequences of traffic flow. These include handling vehicles at intersecting road segments, calculating the velocity of travel on a road segment as a function of its vehicle density, and accounting for the delay of vehicles in traffic queues. The program also models the distribution of times required by individuals to prepare for an evacuation. In order to test its accuracy, the CLEAR model was used to estimate evacuatlon tlmes for the emergency planning zone surrounding the Beaver Valley Nuclear Power Plant. The Beaver Valley site was selected because evacuation time estimates had previously been prepared by the licensee, Duquesne Light, as well as by the Federal Emergency Management Agency and the Pennsylvania Emergency Management Agency. A lack of documentation prevented a detailed comparison of the estimates based on the CLEAR model and those obtained by Duquesne Light. However, the CLEAR model results compared favorably with the estimates prepared by the other two agencies.

Moeller, M. P.; Urbanik, II, T.; Desrosiers, A. E.

1982-03-01T23:59:59.000Z

80

Delayed Neutron and Delayed Photon Characteristics from Photofission of Actinides  

SciTech Connect (OSTI)

Delayed neutron (DN) and delayed photon (DP) emissions from photofission reactions play an important role for applications involving nuclear material detection and characterization. To provide new, accurate, basic nuclear data for evaluations and data libraries, an experimental programme of DN and DP measurements has been undertaken for actinides with bremsstrahlung endpoint energy in the giant resonance region ({approx}15 MeV). In this paper, the experimental setup and the data analysis method will be described. Experimental results for DN and DP characteristics will be presented for {sup 232}Th, {sup 235,238}U, {sup 237}Np, and {sup 239}Pu. Finally, an example of an application to study the contents of nuclear waste packages will be briefly discussed.

Dore, D.; Berthoumieux, E.; Leprince, A.; Ridikas, D. [DSM/IRFUS/PhN, CEA/Saclay, Gif-sur-Yvette, F-91191 (France); Ledoux, X. [CEA/DAM/DIF, Arpajon, F-91297 (France); Agelou, M.; Carrel, F.; Gmar, M. [CEA, LIST, Gif-sur-Yvette, F-91191 (France)

2011-12-13T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

LMFBR fuel-design environment for endurance testing, primarily of oxide fuel elements with local faults  

SciTech Connect (OSTI)

The US Department of Energy LMFBR Lines-of-Assurance are briefly stated and local faults are given perspective with an historical review and definition to help define the constraints of LMFBR fuel-element designs. Local-fault-propagation (fuel-element failure-propagation and blockage propagation) perceptions are reviewed. Fuel pin designs and major LMFBR parameters affecting pin performance are summarized. The interpretation of failed-fuel data is aided by a discussion of the effects of nonprototypicalities. The fuel-pin endurance expected in the US, USSR, France, UK, Japan, and West Germany is outlined. Finally, fuel-failure detection and location by delayed-neutron and gaseous-fission-product monitors are briefly discussed to better realize the operational limits.

Warinner, D.K.

1980-01-01T23:59:59.000Z

82

Empirical timing analysis of CPUs and delay fault tolerant design using partial redundancy  

E-Print Network [OSTI]

and the dynamic frequency-step-down takes place before a pipe flush, and retry is issued. The significant timing overhead associated with the retry is offset by the rarity of the timing violation events. Simulation results on ISCAS Benchmark circuits show that 10...

Chang, Sanghoan

2009-05-15T23:59:59.000Z

83

Communication delay analysis of fault-tolerant pipelined circuit switching in torus  

E-Print Network [OSTI]

Safaei,F. Khonsari,A. Ould-Khaoua,M. Journal of Computer and System Sciences, to appear, 2008, ISSN: 0022-0000. Elsevier Science

Safaei, F.; Khonsari, A.; Ould-Khaoua, M.

84

Improving Diagnostic Resolution of Delay Faults in FPGAs by Exploiting Reconfigurability  

E-Print Network [OSTI]

as a graduate student at the Univ. of Texas, Austin. Proceedings of the 2001 IEEE International Symposium Ghosh-Dastidar* and Nur A. Touba Computer Engineering Research Center Department of Electrical Given an FPGA that has failed to meet its timing specification, techniques are proposed to efficiently

Touba, Nur A.

85

High Quality Compact Delay Test Generation  

E-Print Network [OSTI]

Delay testing is used to detect timing defects and ensure that a circuit meets its timing specifications. The growing need for delay testing is a result of the advances in deep submicron (DSM) semiconductor technology and the increase in clock...

Wang, Zheng

2011-08-08T23:59:59.000Z

86

Advanced ThioClear process testing. Final report  

SciTech Connect (OSTI)

Wet scrubbing is the leading proven commercial post-combustion FGD technology available to meet the sulfur dioxide reductions required by the Clean Air Act Amendments. To reduce costs associated with wet FGD, Dravo Lime Company has developed the ThioClear process. ThioClear is an ex-situ forced oxidation magnesium-enhanced lime FGD process. ThioClear process differs from the conventional magnesium-enhanced lime process in that the recycle liquor has minimal suspended solids and the by-products are wallboard quality gypsum and magnesium hydroxide, an excellent reagent for water treatment. The process has demonstrated sulfur dioxide removal efficiencies of +95% in both a vertical spray scrubber tower and a horizontal absorber operating at gas velocities of 16 fps, respectively. This report details the optimization studies and associated economics from testing conducted at Dravo Lime Company`s pilot plant located at the Miami Fort Station of the Cincinnati Gas and Electric Company.

Lani, B.

1998-03-01T23:59:59.000Z

87

Scattering and; Delay, Scale, and Sum Migration  

SciTech Connect (OSTI)

How do we see? What is the mechanism? Consider standing in an open field on a clear sunny day. In the field are a yellow dog and a blue ball. From a wave-based remote sensing point of view the sun is a source of radiation. It is a broadband electromagnetic source which, for the purposes of this introduction, only the visible spectrum is considered (approximately 390 to 750 nanometers or 400 to 769 TeraHertz). The source emits an incident field into the known background environment which, for this example, is free space. The incident field propagates until it strikes an object or target, either the yellow dog or the blue ball. The interaction of the incident field with an object results in a scattered field. The scattered field arises from a mis-match between the background refractive index, considered to be unity, and the scattering object refractive index ('yellow' for the case of the dog, and 'blue' for the ball). This is also known as an impedance mis-match. The scattering objects are referred to as secondary sources of radiation, that radiation being the scattered field which propagates until it is measured by the two receivers known as 'eyes'. The eyes focus the measured scattered field to form images which are processed by the 'wetware' of the brain for detection, identification, and localization. When time series representations of the measured scattered field are available, the image forming focusing process can be mathematically modeled by delayed, scaled, and summed migration. This concept of optical propagation, scattering, and focusing have one-to-one equivalents in the acoustic realm. This document is intended to present the basic concepts of scalar scattering and migration used in wide band wave-based remote sensing and imaging. The terms beamforming and (delayed, scaled, and summed) migration are used interchangeably but are to be distinguished from the narrow band (frequency domain) beamforming to determine the direction of arrival of a signal, and seismic migration in which wide band time series are shifted but not to form images per se. Section 3 presents a mostly graphically-based motivation and summary of delay, scale, and sum beamforming. The model for incident field propagation in free space is derived in Section 4 under specific assumptions. General object scattering is derived in Section 5 and simplified under the Born approximation in Section 6. The model of this section serves as the basis in the derivation of time-domain migration. The Foldy-Lax, full point scatterer scattering, method is derived in Section 7. With the previous forward models in hand, delay, scale, and sum beamforming is derived in Section 8. Finally, proof-of-principle experiments are present in Section 9.

Lehman, S K

2011-07-06T23:59:59.000Z

88

Mechanical Models of Fault-Related Folding  

SciTech Connect (OSTI)

The subject of the proposed research is fault-related folding and ground deformation. The results are relevant to oil-producing structures throughout the world, to understanding of damage that has been observed along and near earthquake ruptures, and to earthquake-producing structures in California and other tectonically-active areas. The objectives of the proposed research were to provide both a unified, mechanical infrastructure for studies of fault-related foldings and to present the results in computer programs that have graphical users interfaces (GUIs) so that structural geologists and geophysicists can model a wide variety of fault-related folds (FaRFs).

Johnson, A. M.

2003-01-09T23:59:59.000Z

89

Power System Security in Market Clearing and Dispatch Mechanisms  

E-Print Network [OSTI]

congestion" levels, which have a direct effect on market transactions and energy prices. Thus, when result in curtailment of power transactions and increased prices for most market participants. System1 Power System Security in Market Clearing and Dispatch Mechanisms Claudio A. Ca~nizares, Senior

Cañizares, Claudio A.

90

Radiation budget changes with dry forest clearing in temperate Argentina  

E-Print Network [OSTI]

Radiation budget changes with dry forest clearing in temperate Argentina J A V I E R H O U S P A N, Argentina, Catedra de Climatologia Agricola, Facultad de Ciencias Agropecuarias, Universidad Nacional de Entre Rios, Oro Verde, Argentina Abstract Land cover changes may affect climate and the energy balance

Nacional de San Luis, Universidad

91

Service Contract Addition Please type or print information clearly  

E-Print Network [OSTI]

Service Contract Addition Please type or print information clearly Purchasing Department, Building for the service contract. If the item is part of an equipment system, all accessories must be listed. When adding 18. Serial Number 19. Location (Bldg./Rm.) 20. Requested Start Date 21. Service Contract Vendor 22

Wlodawer, Alexander

92

1 INTRODUCTION The replacement investment decision is clearly a  

E-Print Network [OSTI]

1 INTRODUCTION The replacement investment decision is clearly a strategic objective of a company for the replacement decision largely depends on the company context. However, we can summarize the motivations leading over time and prove that the replacement policy at equal intervals is optimum. However, the linear

Paris-Sud XI, Université de

93

Neural net application to transmission line fault detection and classification  

E-Print Network [OSTI]

, is to perform fault analysis by expert operators using their knowledge about the power systems and experience with past faults. Because of the time required to deal with complex fault situations, detailed fault analysis can not be performed by human operators...

Rikalo, Igor

1994-01-01T23:59:59.000Z

94

Development of Hydrologic Characterization Technology of Fault Zones  

E-Print Network [OSTI]

rock interaction, fracture interconnectivity, fault-rockvalues, given the interconnectivity of fractures that are

Karasaki, Kenzi

2009-01-01T23:59:59.000Z

95

Fault Tolerant Control using Cartesian Genetic Programming  

E-Print Network [OSTI]

Fault Tolerant Control using Cartesian Genetic Programming Yoshikazu Hirayama University of York]: Robotics-- Sensors; F.2.2 [Analysis of Algorithms and Problem Complexity]: Nonnumerical Algorithms and Problems General Terms Algorithms, Reliability Keywords cartesian genetic programming, evolutionary

Fernandez, Thomas

96

Microscopic feather fractures in the faulting process  

E-Print Network [OSTI]

assumptions. Although the problem was not solved in this study, the expected ol trajectories for such a solution are shown in Figure 5 (page 20). Both of these concepts indicate a tendency for the local ol to make an angle with the fault greater than 6..., maximum compressive stress, trajectories to a two dimensional during sliding along (dashed lines) in a cylindrical specimen reduced elastic problem. (b) Expected ol trajectories a fault. crack by shear along the crack surfaces (Bieniawski, 1967...

Conrad, Robert Eugene

1974-01-01T23:59:59.000Z

97

Controlling the Delay of Small Flows in Datacenters  

E-Print Network [OSTI]

and CAPEX and ignore designs which could help reduce delay of delay sensitive flows. The flow routing

Carra, Damiano

98

ClearFuels-Rentech Integrated Biorefinery Final Report  

SciTech Connect (OSTI)

The project Final Report describes the validation of the performance of the integration of two technologies that were proven individually on a pilot scale and were demonstrated as a pilot scale integrated biorefinery. The integrated technologies were a larger scale ClearFuels’ (CF) advanced flexible biomass to syngas thermochemical high efficiency hydrothermal reformer (HEHTR) technology with Rentech’s (RTK) existing synthetic gas to liquids (GTL) technology.

Pearson, Joshua [Project Director

2014-02-26T23:59:59.000Z

99

E-Print Network 3.0 - andreas fault zone Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Chester Summary: accommodated along large plate-boundary faults like the San Andreas transform fault in California. These faults... depend in part on the structure of the tabular...

100

E-Print Network 3.0 - active fault zone Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Earth Structure (2nd Edition), 2004 Summary: 292010 Oceanic Transform Faults and Fracture Zones Transform Fault: Active displacement. Fracture Zone: Fossil... fault, no active...

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Development of a Hydrologic Characterization Technology for Fault Zones Final Report  

E-Print Network [OSTI]

Hydrologic Characterization Technology of Fault Zones, Phaseof Characterization Technology for Fault Zones, LBNL-1635E,Characterization on Technology of Fault Zones – Phase II

Karasaki, Kenzi

2014-01-01T23:59:59.000Z

102

Measuring and Modeling Fault Density for Plume-Fault Encounter Probability Estimation  

SciTech Connect (OSTI)

Emission of carbon dioxide from fossil-fueled power generation stations contributes to global climate change. Storage of this carbon dioxide within the pores of geologic strata (geologic carbon storage) is one approach to mitigating the climate change that would otherwise occur. The large storage volume needed for this mitigation requires injection into brine-filled pore space in reservoir strata overlain by cap rocks. One of the main concerns of storage in such rocks is leakage via faults. In the early stages of site selection, site-specific fault coverages are often not available. This necessitates a method for using available fault data to develop an estimate of the likelihood of injected carbon dioxide encountering and migrating up a fault, primarily due to buoyancy. Fault population statistics provide one of the main inputs to calculate the encounter probability. Previous fault population statistics work is shown to be applicable to areal fault density statistics. This result is applied to a case study in the southern portion of the San Joaquin Basin with the result that the probability of a carbon dioxide plume from a previously planned injection had a 3% chance of encountering a fully seal offsetting fault.

Jordan, P.D.; Oldenburg, C.M.; Nicot, J.-P.

2011-05-15T23:59:59.000Z

103

Forecasting stratospheric clear-air turbulence by discriminant analysis  

E-Print Network [OSTI]

by Discriminant Analysis. (December lg73) Robert Earl Cox, A. B. , Dartmouth College Directed by: Dr. Jam s R. Scoggins The appllca'bili. ty of the statis! ical method of discriminart sna1ysis Lo the prediction of clear-air turbulence over the western Unixed... OF THE LITFRATURE b. Current related research 3. TUPJIVLENCE AND ITS PREDICTION a. Mathematical formulation b. The case for statistical prediction 12 4. ANALYTICAL METHODS 16 a. Data b. Discriminant analysis c. Selection of variables 22 5. RESULTS a...

Cox, Robert Earl

1973-01-01T23:59:59.000Z

104

Delays, Unstable Particles, and Transport Theory  

E-Print Network [OSTI]

Delays associated with elementary interaction processes are investigated. The case of broad resonances is discussed in the context of reaction simulations.

P. Danielewicz; S. Pratt

1997-02-18T23:59:59.000Z

105

A Time Delay for the Largest Gravitationally Lensed Quasar: SDSS J1004+4112  

E-Print Network [OSTI]

We present 426 epochs of optical monitoring data spanning 1000 days from December 2003 to June 2006 for the gravitationally lensed quasar SDSS J1004+4112. The time delay between the A and B images is 38.4+/-2.0 days in the expected sense that B leads A and the overall time ordering is C-B-A-D-E. The measured delay invalidates all published models. The models failed because they neglected the perturbations from cluster member galaxies. Models including the galaxies can fit the data well, but strong conclusions about the cluster mass distribution should await the measurement of the longer, and less substructure sensitive, delays of the C and D images. For these images, a CB delay of 681+/-15 days is plausible but requires confirmation, while CB and AD delays of >560 days and > 800 days are required. We clearly detect microlensing of the A/B images, with the delay-corrected flux ratios changing from B-A=0.44+/-0.01 mag in the first season to 0.29+/-0.01 mag in the second season and 0.32+/-0.01 mag in the third season.

J. Fohlmeister; C. S. Kochanek; E. E. Falco; J. Wambsganss; N. Morgan; C. W. Morgan; E. O. Ofek; D. Maoz; C. R. Keeton; J. C. Barentine; G. Dalton; J. Dembicky; W. Ketzeback; R. McMillan; C. S. Peters

2006-07-21T23:59:59.000Z

106

Scientific drilling into the San Andreas fault and site characterization research: Planning and coordination efforts. Final technical report  

SciTech Connect (OSTI)

The fundamental scientific issue addressed in this proposal, obtaining an improved understanding of the physical and chemical processes responsible for earthquakes along major fault zones, is clearly of global scientific interest. By sampling the San Andreas fault zone and making direct measurements of fault zone properties to 4.0 km at Parkfield they will be studying an active plate-boundary fault at a depth where aseismic creep and small earthquakes occur and where a number of the scientific questions associated with deeper fault zone drilling can begin to be addressed. Also, the technological challenges associated with drilling, coring, downhole measurements and borehole instrumentation that may eventually have to be faced in deeper drilling can first be addressed at moderate depth and temperature in the Parkfield hole. Throughout the planning process leading to the development of this proposal they have invited participation by scientists from around the world. As a result, the workshops and meetings they have held for this project have involved about 350 scientists and engineers from about a dozen countries.

Zoback, M.D.

1998-08-30T23:59:59.000Z

107

VCSEL fault location apparatus and method  

DOE Patents [OSTI]

An apparatus for locating a fault within an optical fiber is disclosed. The apparatus, which can be formed as a part of a fiber-optic transmitter or as a stand-alone instrument, utilizes a vertical-cavity surface-emitting laser (VCSEL) to generate a test pulse of light which is coupled into an optical fiber under test. The VCSEL is subsequently reconfigured by changing a bias voltage thereto and is used as a resonant-cavity photodetector (RCPD) to detect a portion of the test light pulse which is reflected or scattered from any fault within the optical fiber. A time interval .DELTA.t between an instant in time when the test light pulse is generated and the time the reflected or scattered portion is detected can then be used to determine the location of the fault within the optical fiber.

Keeler, Gordon A. (Albuquerque, NM); Serkland, Darwin K. (Albuquerque, NM)

2007-05-15T23:59:59.000Z

108

Benchmark Results for Delayed Neutron Data  

SciTech Connect (OSTI)

We have calculated the effective delayed neutron fraction {beta}eff for 32 benchmark configurations for which measurements have been reported. We use these results to test the delayed neutron data of JEFF-3.0, ENDF/B-VI.8, and JENDL-3.3.

Marck, S.C. van der; Meulekamp, R. Klein; Hogenbirk, A.; Koning, A.J. [Nuclear Research and Consultancy Group NRG, P.O. Box 25, NL-1755 ZG Petten (Netherlands)

2005-05-24T23:59:59.000Z

109

The Tunnel Vision Syndrome: Massively Delaying Progress  

E-Print Network [OSTI]

The Tunnel Vision Syndrome: Massively Delaying Progress Reiner Hartenstein, Professor, IEEE fellow facet as the complete answer are far from solving the problem. What is the reason of these slow-down- stream-based computing was delayed for decades by the tunnel vision syndrome. The History of Systolic

Hartenstein, Reiner

110

Synthesis and evaluation of fault-tolerant quantum computer architectures  

E-Print Network [OSTI]

Fault-tolerance is the cornerstone of practical, large-scale quantum computing, pushed into its prominent position with heroic theoretical efforts. The fault-tolerance threshold, which is the component failure probability ...

Cross, Andrew W. (Andrew William), 1979-

2005-01-01T23:59:59.000Z

111

Observations on the capability of the Criner fault, southern Oklahoma  

E-Print Network [OSTI]

Results of previous investigations have indicated the possibility that recent deformation has occurred on the Criner fault of southern Oklahoma. The Criner fault is located in Carter and Love Counties, Oklahoma, approximately 100 kilometers...

Williamson, Shawn Collin

2012-06-07T23:59:59.000Z

112

Scalable, Fault-tolerant Management in a Service Oriented Architecture  

E-Print Network [OSTI]

Scalable, Fault-tolerant Management in a Service Oriented Architecture Harshawardhan Gadgil: Scalable, Fault-tolerance, Service Oriented Management, Architecture 1. Introduction With the explosion. The service-oriented architecture provides a simple and flexible framework for building sophisticated

113

FEATURE BASED HANDLING OF SURFACE FAULTS IN COMPACT DISC PLAYERS  

E-Print Network [OSTI]

two photo detectors. The distances are the distance from the actual position of the OPU such surface faults. The core idea is not to rely on sensor information during the fault. The sensor signals

Wickerhauser, M. Victor

114

New approach to the fault location problem using synchronized sampling  

E-Print Network [OSTI]

This thesis presents a new approach to solving the problem of fault location on a transmission line using synchronized data from both ends of the line. The synchronized phase voltage and current samples taken during the fault transient are used...

Mrkic, Jasna

2012-06-07T23:59:59.000Z

115

Frictional properties of faults: from observation on the  

E-Print Network [OSTI]

Frictional properties of faults: from observation on the Longitudinal Valley Fault, Taiwan myself lucky to do what I love and to wake up every day, happy and excited about the day to come

Winfree, Erik

116

Robust model-based fault diagnosis for chemical process systems  

E-Print Network [OSTI]

diagnosis systems, which use limited information about the process model to robustly detect, discriminate, and reconstruct instrumentation faults. Broadly, the proposed method consists of a novel nonlinear state and parameter estimator coupled with a fault...

Rajaraman, Srinivasan

2006-08-16T23:59:59.000Z

117

Development of a bridge fault extractor tool  

E-Print Network [OSTI]

are tools that analyze chip layouts and produce a realistic list of bridging faults within that chip. FedEx, previously developed at Texas A&M University, extracts all two-node intralayer bridges of any given chip layout and optionally extracts all two...) for this tool which aids in more effectively visualizing the bridge faults across the chip. The final aim of this thesis was to perform FedEx output analysis to understand the nature of the defects, such as variation of critical area (the area where...

Bhat, Nandan D.

2005-02-17T23:59:59.000Z

118

Beta-Delayed Two-Particle Emission  

SciTech Connect (OSTI)

A panorama of beta-delayed nuclear decay is sketched. Beginning with beta-delayed two-neutron emission, the author moves on to beta-delayed two-proton emission and beta-delayed multiparticle emission. After touching briefly on the theoretical approach to understanding these phenomena, he reports on two experiments done at ISOLDE (CERN) on the decay of {sup 31}Ar with the goal of studying the mechanisms of {beta}-delayed two proton emission. This example shows the potentiality of the new technology that allows design setups with high efficiency for multiparticle detection. In combination with high-purity sources and the use of low-energy beams to produce point-like sources, information at the drip line can be extracted that is of comparable quality to that obtained near stability.

Borge, M.J.G.

2000-12-31T23:59:59.000Z

119

First Observation of Beta-Delayed Three-Proton Emission in 45Fe  

SciTech Connect (OSTI)

The decay of extremely neutron deficient 45Fe has been studied by means of a new type of a gaseous detector in which a technique of digital imaging was used to record tracks of charged particles. The + decay channels accompanied by proton emission were clearly identified. In addition to -delayed one-proton and -delayed two-proton decays, -delayed three-proton emission was recorded which represents the first direct and unambiguous observation of this decay channel. The branching ratio for the decay of 45Fe and the corresponding partial half-life are found to be 0.30 0.04 and T1/2( ) = 8.7 1.3 ms, respectively.

Miernik, K. [University of Warsaw; Dominik, Wojciech [Warsaw University; Janas, Z. [University of Warsaw; Pfutzner, M. [University of Warsaw; Bingham, C. R. [University of Tennessee, Knoxville (UTK); Czyrkowski, Henryk [Warsaw University; Cwiok, Mikolaj [Warsaw University; Darby, Iain [University of Tennessee, Knoxville (UTK); Djbrowski, R. [University of Warsaw; Ginter, T. N. [Michigan State University, East Lansing; Grzywacz, R. [University of Tennessee, Knoxville (UTK); Karny, M. [University of Warsaw; Korgul, A. [University of Warsaw; Kusmierz, W. [University of Warsaw; Liddick, Sean [University of Tennessee, Knoxville (UTK); Rajabali, Mustafa [University of Tennessee, Knoxville (UTK); Rykaczewski, Krzysztof Piotr [ORNL; Stolz, A. [Michigan State University, East Lansing

2007-01-01T23:59:59.000Z

120

First observation of {beta}-delayed three-proton emission in {sup 45}Fe  

SciTech Connect (OSTI)

The decay of extremely neutron deficient {sup 45}Fe has been studied by means of a new type of a gaseous detector in which a technique of digital imaging was used to record tracks of charged particles. The {beta}{sup +} decay channels accompanied by proton emission were clearly identified. In addition to {beta}-delayed one-proton and {beta}-delayed two-proton decays, {beta}-delayed three-proton emission was recorded which represents the first direct and unambiguous observation of this decay channel. The branching ratio for the {beta} decay of {sup 45}Fe and the corresponding partial half-life are found to be 0.30{+-}0.04 and T{sub 1/2}({beta})=8.7{+-}1.3 ms, respectively.

Miernik, K.; Dominik, W.; Janas, Z.; Pfuetzner, M.; Czyrkowski, H.; Cwiok, M.; DaPbrowski, R.; Karny, M.; Korgul, A.; Kusmierz, W. [Institute of Experimental Physics, Warsaw University, PL-00-681 Warsaw (Poland); Bingham, C. R.; Darby, I. G.; Liddick, S. N.; Rajabali, M. [Department of Physics and Astronomy, University of Tennessee, Knoxville, Tennessee 37996 (United States); Ginter, T.; Stolz, A. [National Superconducting Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States); Grzywacz, R. [Department of Physics and Astronomy, University of Tennessee, Knoxville, Tennessee 37996 (United States); Physics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States); Rykaczewski, K. [Physics Division, Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)

2007-10-15T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Understanding Fault Characteristics of Inverter-Based Distributed Energy Resources  

SciTech Connect (OSTI)

This report discusses issues and provides solutions for dealing with fault current contributions from inverter-based distributed energy resources.

Keller, J.; Kroposki, B.

2010-01-01T23:59:59.000Z

122

Statistical estimation of multiple faults in aircraft gas turbine engines  

E-Print Network [OSTI]

415 Statistical estimation of multiple faults in aircraft gas turbine engines S Sarkar, C Rao of multiple faults in aircraft gas-turbine engines, based on a statistical pattern recognition tool called commercial aircraft engine. Keywords: aircraft propulsion, gas turbine engines, multiple fault estimation

Ray, Asok

123

A Parametric Spectral Estimator for Faults Detection in Induction Machines  

E-Print Network [OSTI]

for fault diagnosis in electrical machines. Current spectral estimation is usually performed using classical and productivity of electrical drives. For electrical motors and generators, fault detection is usually performedA Parametric Spectral Estimator for Faults Detection in Induction Machines El Houssin El Bouchikhi

Boyer, Edmond

124

UNSUPERVISED CLUSTERING FOR FAULT DIAGNOSIS IN NUCLEAR POWER PLANT COMPONENTS  

E-Print Network [OSTI]

1 UNSUPERVISED CLUSTERING FOR FAULT DIAGNOSIS IN NUCLEAR POWER PLANT COMPONENTS Piero Baraldi1 of prototypical behaviors. Its performance is tested with respect to an artificial case study and then applied on transients originated by different faults in the pressurizer of a nuclear power reactor. Key Words: Fault

Boyer, Edmond

125

Diverse neural net solutions to a fault diagnosis problem \\Lambda  

E-Print Network [OSTI]

Abstract The development of a neural net system for fault diagnosis in a mar­ ine diesel engine system solution to a problem of fault diagnosis in a four­stroke marine diesel engine; that of early to recognise faults in simulated data from a diesel engine; specifically to classify combustion condition

Sharkey, Amanda

126

The LMFBR fuel-design environment for endurance testing, primarily of oxide fuel elements with local faults  

SciTech Connect (OSTI)

The U.S. Department of Energy LMFBR Lines-of-Assurance are briefly stated and local faults are given perspective with an historical review and definition to help define the constraints of LMFBR fuel-element designs. Local-fault-propagation (fuel-element-failure propagation and blockage propagation) perceptions are reviewed. Fuel pin designs and major LMFBR parameters affecting pin performance are summarized. The interpretation of failed-fuel data is aided by a discussion of the effects of nonprototypicalities. The fuel-pin endurances expected in the United States, USSR, France, UK, Japan, and West Germany are outlined. Finally, fuel-failure detection and location by delayed-neutron and gaseous-fission product monitors are briefly discussed to better realize the operational limits.

Warinner, D.K.

1983-07-01T23:59:59.000Z

127

An adaptive algorithm for the detection of high impedance faults on power distribution systems  

E-Print Network [OSTI]

heterogeneous level 2 events. The class of such an event probably could not be clearly determined, but due to the persistence of most faults, the next event would be homogeneous. TRL2 1. Initialize: p;, C(p;), n? i = 1, . . . , Nr are given, qp = p = 0... OF LITERATURE III TRAINING ALGORITHMS 12 A. Overview . B. Level 1 Training Algorithm (TRL1) C. Level 2 Training Algorithm (TRL2) IV ONLINE ALGORITHM 12 13 18 21 A. Extensions to TRL2 B. ONLINE algorithm V IMPLEMENTATION AND RESULTS 21 24 27 VI A...

McCall, Kurt Eric

1990-01-01T23:59:59.000Z

128

Structure of the eastern Red Rocks and Wind Ridge thrust faults, Wyoming: how a thrust fault gains displacement along strike  

E-Print Network [OSTI]

STRUCTURE OF THE EASTERN RED ROCKS AND WIND RIDGE THRUST FAULTS, WYOMING: HOW A THRUST FAULT GAINS DISPLACEMENT ALONG STRIKE A Thesis by BRENT STANLEY HUNTSMAN Submitted to the Graduate College of Texas A&M University in partial fulfillment... of the requirements for the degree of MASTER OF SCIENCE December 1983 Major Subject: Geology STRUCTURE OF THE EASTERN RED ROCKS AND WIND RIDGE THRUST FAULTS, WYOMING: HOW A THRUST FAULT GAINS DISPLACEMENT ALONG STRIKE A Thesis by BRENT STANLEY HUNTSMAN...

Huntsman, Brent Stanley

1983-01-01T23:59:59.000Z

129

Seismoelectric Imaging of a Shallow Fault System Employing Fault Guided Waves  

E-Print Network [OSTI]

Independent sets of reflection seismic and seismoelectric data were collected, processed, and interpreted with the aim of generating and studying guided waves within a fault zone. While seismic surveys have recently been utilized to investigate...

Cohrs, Frelynn Joseph Reese

2012-07-16T23:59:59.000Z

130

Fault Tolerant CORBASpecification, OMG document: ptc/20000404  

E-Print Network [OSTI]

Fault Tolerant CORBASpecification, V1.0 OMG document: ptc/2000­04­04 replaces draft adopted specification ptc/2000­03­04 and submission document orbos/00­01­19 This document is an OMG Final Adopted in the finalization phase. Comments on the content of this document are welcomed, and should be directed to issues

Roma "La Sapienza", Università di

131

Global Trajectory Planning for Fault Tolerant Manipulators  

E-Print Network [OSTI]

. Khosla Department of Electrical and Computer Engineering and The Robotics Institute, Carnegie Mellon attribute of robot manipulators in a growing range of applications such as space missions, nuclear waste retrieval, and medical robot­ ics. This trend has spawned a research effort in fault toler­ ant robotics

132

Fault-tolerant, Universal Adiabatic Quantum Computation  

E-Print Network [OSTI]

Quantum computation has revolutionary potential for speeding computational tasks such as factoring and simulating quantum systems, but the task of constructing a quantum computer is daunting. Adiabatic quantum computation and other ``hands-off" approaches relieve the need for rapid, precise pulsing to control the system, inspiring at least one high-profile effort to realize a hands-off quantum computing device. But is hands-off incompatible with fault-tolerant? Concerted effort and many innovative ideas have not resolved this question but have instead deepened it, linking it to fundamental problems in quantum complexity theory. Here we present a hands-off approach that is provably (a) capable of scalable universal quantum computation in a non-degenerate ground state and (b) fault-tolerant against an analogue of the usual local stochastic fault model. A satisfying physical and numerical argument indicates that (c) it is also fault-tolerant against thermal excitation below a threshold temperature independent of the computation size.

Ari Mizel

2014-03-30T23:59:59.000Z

133

All row, planar fault detection system  

DOE Patents [OSTI]

An apparatus, program product and method for detecting nodal faults may simultaneously cause designated nodes of a cell to communicate with all nodes adjacent to each of the designated nodes. Furthermore, all nodes along the axes of the designated nodes are made to communicate with their adjacent nodes, and the communications are analyzed to determine if a node or connection is faulty.

Archer, Charles Jens; Pinnow, Kurt Walter; Ratterman, Joseph D; Smith, Brian Edward

2013-07-23T23:59:59.000Z

134

Coordinated Fault Tolerance for High-Performance Computing  

SciTech Connect (OSTI)

Our work to meet our goal of end-to-end fault tolerance has focused on two areas: (1) improving fault tolerance in various software currently available and widely used throughout the HEC domain and (2) using fault information exchange and coordination to achieve holistic, systemwide fault tolerance and understanding how to design and implement interfaces for integrating fault tolerance features for multiple layers of the software stack—from the application, math libraries, and programming language runtime to other common system software such as jobs schedulers, resource managers, and monitoring tools.

Dongarra, Jack; Bosilca, George; et al.

2013-04-08T23:59:59.000Z

135

Probabilistic model of fault detection in quantum circuits  

E-Print Network [OSTI]

It is shown that the fault testing for quantum circuits does not follow conventional classical techniques. If probabilistic gate like Hadamard gate is included in a circuit then the classical notion of test vector is shown to fail. We have reported several new and distinguishing features of quantum fault and also presented a general methodology for detection of functional faults in a quantum circuit. The technique can generate test vectors for detection of different kinds of fault. Specific examples are given and time complexity of the proposed quantum fault detection algorithm is reported.

Anindita Banerjee; Anirban Pathak

2009-05-12T23:59:59.000Z

136

Identification and use of surrogate precursors to represent delayed neutron groups  

SciTech Connect (OSTI)

Time-dependent delayed neutron activities have traditionally been represented by six delayed neutron precursor groups, whose yields and decay constants are obtained from nonlinear least-squares fits to out-of-pile measurements. The group decay constants obtained in this manner are empirical. They do not coincide with decay constants of specific delayed neutron precursors. Different values are used for each fissionable nuclide, and the values used also depend on the energy spectrum of the neutrons causing fission. Having a different value of the six-group decay constants for each fissionable nuclide complicates the analysis of the dynamic behavior of fast reactors. A fast reactor containing six principal fissioning nuclides of uranium and plutonium must, in effect, be described by 36 delayed neutron groups. The use of group decay constants that depend on the neutron energy spectrum makes it difficult to select values that describe the dynamic response of epithermal systems because virtually all delayed neutron activity measurements have been performed for fast or thermal spectra. Clearly, it would be desirable to have a single set of group decay constants that could be applied to all fissionable nuclei. A set of seven fixed decay constants is associated with a specific, dominant delayed neutron precursor. In effect, each group is represented by a single surrogate precursor. Using recently measured delayed neutron activities for {sup 235}U and {sup 237}Np, the proposed set of decay constants actually improved the fit to the data. For other fissionable nuclei, a method has been devised to obtain yields consistent with the proposed set of decay constants from the traditional six-group parameters. This transformation is accomplished without altering the inferred reactivity scale.

Loaiza, D.J. [Los Alamos National Lab., NM (United States); Haskin, F.E. [Univ. of New Mexico, Albuquerque, NM (United States)

1998-09-01T23:59:59.000Z

137

Uncertainty evaluation of delayed neutron decay parameters  

E-Print Network [OSTI]

parameters fit their individual measurement data well in spite of these differences. This dissertation focuses on evaluation of the errors and methods of delayed neutron relative yields and decay constants for thermal fission of U-235. Various numerical...

Wang, Jinkai

2009-05-15T23:59:59.000Z

138

Construction project delay-analysis techniques  

E-Print Network [OSTI]

of this rcscarch bcncfit different parties among the construction industry such as the owners, dcsigncrs, contractors, and lawyers. DEDICATION For my parents, Haya and Mohammad, whose love and support have guided me throughout and carried me at times. Fo&r... OWNER PROJECT 3 AS-BUILT WITHOUT DELAY SCHEDULE APPENDIX D PUBLIC OWNER 3 SNAPSHOT SCHEDULE ON APRIL 21, 1997 . APPENDIX E PUBLIC OWNER 3 SNAPSHOT SCHEDULE ON MAY 10 ", 1997. APPENDIX F PUBLIC OWNER 3 DELAY-ANALYSIS USING ANALYSIS...

Al-Humaidi, Hanouf M

2012-06-07T23:59:59.000Z

139

Evaluation of Clear Sky Models for Satellite-Based Irradiance Estimates  

SciTech Connect (OSTI)

This report describes an intercomparison of three popular broadband clear sky solar irradiance model results with measured data, as well as satellite-based model clear sky results compared to measured clear sky data. The authors conclude that one of the popular clear sky models (the Bird clear sky model developed by Richard Bird and Roland Hulstrom) could serve as a more accurate replacement for current satellite-model clear sky estimations. Additionally, the analysis of the model results with respect to model input parameters indicates that rather than climatological, annual, or monthly mean input data, higher-time-resolution input parameters improve the general clear sky model performance.

Sengupta, M.; Gotseff, P.

2013-12-01T23:59:59.000Z

140

Completing fault models for abductive diagnosis  

SciTech Connect (OSTI)

In logic-based diagnosis, the consistency-based method is used to determine the possible sets of faulty devices. If the fault models of the devices are incomplete or nondeterministic, then this method does not necessarily yield abductive explanations of system behavior. Such explanations give additional information about faulty behavior and can be used for prediction. Unfortunately, system descriptions for the consistency-based method are often not suitable for abductive diagnosis. Methods for completing the fault models for abductive diagnosis have been suggested informally by Poole and by Cox et al. Here we formalize these methods by introducing a standard form for system descriptions. The properties of these methods are determined in relation to consistency-based diagnosis and compared to other ideas for integrating consistency-based and abductive diagnosis.

Knill, E. (Los Alamos National Lab., NM (United States)); Cox, P.T.; Pietrzykowski, T. (Technical Univ., NS (Canada))

1992-11-05T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Calculating the probability of injected carbon dioxide plumes encountering faults  

SciTech Connect (OSTI)

One of the main concerns of storage in saline aquifers is leakage via faults. In the early stages of site selection, site-specific fault coverages are often not available for these aquifers. This necessitates a method using available fault data to estimate the probability of injected carbon dioxide encountering and migrating up a fault. The probability of encounter can be calculated from areal fault density statistics from available data, and carbon dioxide plume dimensions from numerical simulation. Given a number of assumptions, the dimension of the plume perpendicular to a fault times the areal density of faults with offsets greater than some threshold of interest provides probability of the plume encountering such a fault. Application of this result to a previously planned large-scale pilot injection in the southern portion of the San Joaquin Basin yielded a 3% and 7% chance of the plume encountering a fully and half seal offsetting fault, respectively. Subsequently available data indicated a half seal-offsetting fault at a distance from the injection well that implied a 20% probability of encounter for a plume sufficiently large to reach it.

Jordan, P.D.

2011-04-01T23:59:59.000Z

142

Stuck-at-fault test set compaction  

E-Print Network [OSTI]

. Test set size under pattern score based dynamic compaction . . . 13 . . . 17 Figure 7. Pattern Score distribution v:ith pattern metric dynamic compaction. . . . . . . . . . . . . . I g LIST OF TABLES Page Table l. l. nuit Target Sclcction Methods.... Fault Target Selection Methods Random Minimum Detection Count Circuit Name c432 c499 c880 c1355 c1908 G2670 Excitation Balance 0. 136296 0. 191652 0. 170293 0. 173310 0. 187486 0. 190484 Pattern Count 1152 873 2693 1394 1708 5148...

Vanfickell, Jason Michael

2013-02-22T23:59:59.000Z

143

Undulator Hall Air Temperature Fault Scenarios  

SciTech Connect (OSTI)

Recent experience indicates that the LCLS undulator segments must not, at any time following tuning, be allowed to change temperature by more than about {+-}2.5 C or the magnetic center will irreversibly shift outside of acceptable tolerances. This vulnerability raises a concern that under fault conditions the ambient temperature in the Undulator Hall might go outside of the safe range and potentially could require removal and retuning of all the segments. In this note we estimate changes that can be expected in the Undulator Hall air temperature for three fault scenarios: (1) System-wide power failure; (2) Heating Ventilation and Air Conditioning (HVAC) system shutdown; and (3) HVAC system temperature regulation fault. We find that for either a system-wide power failure or an HVAC system shutdown (with the technical equipment left on), the short-term temperature changes of the air would be modest due to the ability of the walls and floor to act as a heat ballast. No action would be needed to protect the undulator system in the event of a system-wide power failure. Some action to adjust the heat balance, in the case of the HVAC power failure with the equipment left on, might be desirable but is not required. On the other hand, a temperature regulation failure of the HVAC system can quickly cause large excursions in air temperature and prompt action would be required to avoid damage to the undulator system.

Sevilla, J.; Welch, J.; /SLAC; ,

2010-11-17T23:59:59.000Z

144

On the modeling of time-varying delays  

E-Print Network [OSTI]

This thesis is an effort to develop generalized dynamic models for systems with time-varying time delays. Unlike the simple time-delay model characterized by a transportation lag in the case of a fixed time delay, time-varying delays exhibit quite...

Shah, Chirag Laxmikant

2004-09-30T23:59:59.000Z

145

In-vessel thermohydraulics evaluation of an unprotected transient overpower accident and delayed neutron precursor concentration transport analysis using a multidimensional code  

SciTech Connect (OSTI)

This paper reports on a three-dimensional in-vessel thermohydraulics analysis that is carried out for the early phase of an unprotected transient overpower (UTOP) accident and delayed neutron precursor concentration transport in a typical loop-type fast breeder reactor plant. In the UTOP calculations, the time at which the sodium temperature reaches the reactor trip level is evaluated based on calculated upper plenum flow and temperature distributions. For fission product release from the core assemblies, the delayed neutron precursor concentration in the sodium that reaches the detectors depends on the location of the faulted assembly. Three-dimensional flow patterns, and hence, the residence time in the upper plenum. Delayed neutron precursors that bypassed the recirculation flow to appear in the plenum primarily contribute to the peak concentration.

Muramatsu, T.; Ninokata, H. (Power Reactor and Nuclear Fuel Development Corp., Tokai, Ibaraki (Japan))

1992-02-01T23:59:59.000Z

146

Delay correlation analysis and representation for vital complaint VHDL models  

DOE Patents [OSTI]

A method and system unbind a rise/fall tuple of a VHDL generic variable and create rise time and fall time generics of each generic variable that are independent of each other. Then, according to a predetermined correlation policy, the method and system collect delay values in a VHDL standard delay file, sort the delay values, remove duplicate delay values, group the delay values into correlation sets, and output an analysis file. The correlation policy may include collecting all generic variables in a VHDL standard delay file, selecting each generic variable, and performing reductions on the set of delay values associated with each selected generic variable.

Rich, Marvin J.; Misra, Ashutosh

2004-11-09T23:59:59.000Z

147

Similarity Matching Techniques for Fault Diagnosis in Automotive Infotainment Electronics  

E-Print Network [OSTI]

Fault diagnosis has become a very important area of research during the last decade due to the advancement of mechanical and electrical systems in industries. The automobile is a crucial field where fault diagnosis is given a special attention. Due to the increasing complexity and newly added features in vehicles, a comprehensive study has to be performed in order to achieve an appropriate diagnosis model. A diagnosis system is capable of identifying the faults of a system by investigating the observable effects (or symptoms). The system categorizes the fault into a diagnosis class and identifies a probable cause based on the supplied fault symptoms. Fault categorization and identification are done using similarity matching techniques. The development of diagnosis classes is done by making use of previous experience, knowledge or information within an application area. The necessary information used may come from several sources of knowledge, such as from system analysis. In this paper similarity matching tec...

Kabir, Mashud

2009-01-01T23:59:59.000Z

148

Pressure test data reveal reservoir barriers/faults  

SciTech Connect (OSTI)

A review of transient pressure test data from an oil reservoir in Libya indicated not only the suspected fault barriers, but also the non-sealing portions of the faults. Extensive seismic data indicated much faulting, and directional trends had been interpreted to be generally northwest-southeast. The reservoir is a heterogeneous dolomite with average permeability of 40 to 50 md and contains neither natural fractures not stratification. Vertical displacement (throw) of each fault block is indicated to be within the range of the dolomite thickness, i.e., 40 to 180 ft. Therefore, when the fault throw is greater than reservoir thickness there is sealing, and when the throw is less than reservoir thickness the faults are non-sealing.

Hurd, J.D.

1984-07-30T23:59:59.000Z

149

Determination of Godiva`s effective delayed neutron fraction using newly calculated delayed neutron spectra  

SciTech Connect (OSTI)

When calculating the effective delayed neutron fraction {beta}{sub eff} for a given reactor system, the assumed delayed neutron group spectra and the assumed number of delayed neutrons born per fission {nu}{sub d} can have a major impact on the final value. Over the years, the recommended values for the delayed neutron spectra and for {nu}{sub d} have slowly changed. To ascertain whether or not these changes have increased the accuracy of {beta}{sub eff} calculations in fast {sup 235}U systems, the authors have reevaluated {beta}{sub eff} for the benchmark system Godiva-I using newly calculated delayed neutron spectra and Tuttle`s recommended values of {nu}{sub d} for both {sup 235}U and {sup 238}U.

Spriggs, G.D.; Campbell, J.M. [Los Alamos National Lab., NM (United States); Busch, R.D. [Univ. of New Mexico, Albuquerque, NM (United States)

1999-09-01T23:59:59.000Z

150

A Turing Machine Resisting Isolated Bursts Of Faults  

E-Print Network [OSTI]

We consider computations of a Turing machine under noise that causes consecutive violations of the machine's transition function. Given a constant upper bound B on the size of bursts of faults, we construct a Turing machine M(B) subject to faults that can simulate any fault-free machine under the condition that bursts are not closer to each other than V for an appropriate V = O(B^2).

Capuni, Ilir

2012-01-01T23:59:59.000Z

151

Fault Detection and Diagnosis Method for VAV Terminal Units  

E-Print Network [OSTI]

: Air density [kg/m3] NOMENCLATURE REFERENCES 1) IEA Annex 25, Building Optimization and Fault Diagnosis Source Book, Eds. J. Hyvarinen and S. Karki, Technical Research Center of Finland, 1996 2) Harunori Yoshida: Typical Faults of Air Conditioning..., IEA Annex 34 ?Detection and Diagnosis Methods in Real Building?, Eds. A. Dexter and J. Pakanen, Section C.2, pp.143-148, 2001 6) Harunori Yoshida, Sanjay Kumar, Yasunori Morita: Online Fault Detection and Diagnosis in VAV Air Handling Unit by RARX...

Miyata, M.; Yoshida, H.; Asada, M.; Wang, F.; Hashiguchi, S.

2004-01-01T23:59:59.000Z

152

Time-delayed quantum feedback control  

E-Print Network [OSTI]

A theory of time-delayed coherent quantum feedback is developed. More specifically, we consider a quantum system coupled to a bosonic reservoir creating a unidirectional feedback loop. It is shown that the dynamics can be mapped onto a fictitious quantum cascade, where the system is driven by past versions of itself. The derivation of this model relies on a tensor network representation of the system-reservoir time-propagator. For concreteness, this general theory is applied to a driven two-level atom scattering into a coherent feedback loop. We demonstrate how delay effects can qualitatively change the dynamics of the atom, and how quantum control can be implemented in the presence of time-delays. A realization with a superconducting qubit serving as an artificial atom is discussed.

Arne L. Grimsmo

2015-02-24T23:59:59.000Z

153

PHOTOVOLTAIC DC ARC FAULT DETECTOR TESTING AT SANDIA NATIONAL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

PHOTOVOLTAIC DC ARC FAULT DETECTOR TESTING AT SANDIA NATIONAL LABORATORIES Jay Johnson 1 , Birger Pahl 2 , Charles Luebke 2 , Tom Pier 2 , Theodore Miller 3 , Jason Strauch 1 ,...

154

automatic fault management: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Software Fault Diagnosis by Exploiting Application Signatures Xiaoning Ding - The Ohio - The Ohio State University ABSTRACT Application problem diagnosis in complex...

155

Active Fault Controls At High-Temperature Geothermal Sites- Prospectin...  

Open Energy Info (EERE)

the level of unrecognized active faults present in these areas. Analysis of low-sun-angle aerial photography acquired over the Needle Rocks, Astor Pass, Empire, and Lee...

156

Controls on Fault-Hosted Fluid Flow: Preliminary Results from...  

Open Energy Info (EERE)

Results from the Coso Geothermal Field, CA Abstract cap rock, permeability, fault, fracture, clay, Coso Authors Davatzes, N.C.; Hickman and S.H. Published Geothermal Resource...

157

Fault-tolerant distributed transactions for partitioned OLTP databases  

E-Print Network [OSTI]

This thesis presents Dtxn, a fault-tolerant distributed transaction system designed specifically for building online transaction processing (OLTP) databases. Databases have traditionally been designed as general purpose ...

Jones, Evan P. C. (Evan Philip Charles), 1981-

2012-01-01T23:59:59.000Z

158

Active Fault Segments As Potential Earthquake Sources- Inferences...  

Open Energy Info (EERE)

have not been investigated to determine their subsurface geometry, faulting intensity and constituents (fluids, sediments) for proper characterization of tectonic rift...

159

Upper crustal faulting in an obliquely extending orogen, structural...  

Open Energy Info (EERE)

eastern California Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Proceedings: Upper crustal faulting in an obliquely extending orogen,...

160

A SIMPLIFIED PROCEDURE FOR CALCULATING THE EFFECTS OF DAYLIGHT FROM CLEAR SKIES  

E-Print Network [OSTI]

J. , "The Calculation of Daylight Factor for Clear Skyand Predetermination of Daylight Illumination," ILLUMINATINGA MEASURING DIAGRAM FOR DAYLIGHT ILLUMINATION, Batsford,

Bryan, Harvey J.

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Seven surrogate precursors for modeling delayed neutron decay and predicting reactivity  

SciTech Connect (OSTI)

The use of a different set of group decay constants for each fissionable nuclide complicates analysis of the dynamic behavior of fast reactors. A fast reactor containing six principal fissioning nuclides of uranium and plutonium must, in effect, be described by 36 delayed neutron groups. Additionally, the use of group decay constants that depend on the neutron energy spectrum makes it difficult to select values that describe the dynamic response of epithermal systems because virtually all delayed neutron activity measurements have been performed for fast or thermal-neutron-induced fission. Clearly, it would be desirable to have a single set of group decay constants that could be applied to all fissionable nuclides. A set of seven fixed decay constants is proposed herein. Each of the proposed decay constants is associated with a specific, dominant delayed neutron precursor. In effect, each group is represented by a single surrogate precursor. Using recently measured delayed neutron activities for U-235 and Np-237, the proposed set of decay constants actually improved the goodness of fit to the data. For other fissionable nuclides lacking experimental data, a method has been devised to obtain yields consistent with the proposed set of decay constants from the traditional six-group parameters. This transformation is accomplished without altering the traditional inferred reactivity scale.

Loaiza, D.J.; Haskin, F.E.

1997-12-31T23:59:59.000Z

162

Efficient Fault Tolerance: an Approach to Deal with Transient Faults in Multiprocessor Architectures  

E-Print Network [OSTI]

, 36, 56126 Pisa, Italy ** IEI/CNR, Via S. Maria, 46, 56126 Pisa, Italy Abstract Dynamic error, while making efficient use of the available resources. To this end, dynamic error processing must is integrated with a mechanism for dynamic error processing in a complete fault tolerance strategy. Reliability

Firenze, Università degli Studi di

163

The structure and evolution of small-displacement strike-slip faults in porous sandstone  

E-Print Network [OSTI]

relationship between the progressive addition of subsidiary fault segments (deformation bands) and earlier-formed linkage structures. The along-strike variability and distribution of fault structure are documented and used to assess the role of early fault...

Schafer, Kirk Wyatt

2002-01-01T23:59:59.000Z

164

Early Holocene and Late Pleistocene slip rates of the southern Dead Sea Fault determined from 10  

E-Print Network [OSTI]

sites located along the Wadi Araba Fault (WAF) segment of the Dead Sea Fault are targeted on the DSF, focusing on the Wadi Araba Fault (WAF) segment (Figure 1b). The WAF strikes N12°E for about 160

Klinger, Yann

165

Neural Network-Based Classification of Single-Phase Distribution Transformer Fault Data  

E-Print Network [OSTI]

The ultimate goal of this research is to develop an online, non-destructive, incipient fault detection system that is able to detect incipient faults in transformers and other electric equipment before the faults become catastrophic...

Zhang, Xujia

2006-08-16T23:59:59.000Z

166

Fewer Faults for Faster Computing | EMSL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation ProposedUsing ZirconiaPolicyFeasibility ofSmall15.000TechnologyTuneFewer Faults for Faster

167

Sandia National Laboratories: parallel arc-fault  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1developmentturbine bladelifetime ismobileparallel arc-fault Sandia Research on PV

168

Sandia National Laboratories: arc-fault detector  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1development Sandia, NREL Release Wavearc-fault circuit interrupter Sandia Research

169

Sandia National Laboratories: Arc-Fault Detection  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1 -the Mid-Infrared0Energy Advanced Nuclear EnergyCouncilSandia's Work withArc-Fault

170

NIH Public Policy Delay before Open  

E-Print Network [OSTI]

Publisher NIH Public Policy Compliance Delay before Open Access NIH Partner? Who Submits article American Physiological Society Yes 12 months Yes Publisher (author needs to report NIH funding) also offers stage (however, agreement allows for this posting at no cost for NIH funded articles) Cell Cycle

Polz, Martin

171

SciTech Connect: Development of Asset Fault Signatures for Prognostic...  

Office of Scientific and Technical Information (OSTI)

Development of Asset Fault Signatures for Prognostic and Health Management in the Nuclear Industry Citation Details In-Document Search Title: Development of Asset Fault Signatures...

172

Fault Analysis at a Wind Power Plant for One Year of Observation: Preprint  

SciTech Connect (OSTI)

This paper analyzes the fault characteristics observed at a wind power plant, and the behavior of the wind power plant under fault events.

Muljadi, E.; Mills, Z.; Foster, R.; Conto, J.; Ellis, A.

2008-07-01T23:59:59.000Z

173

The faults that move during earthquakes do not always come  

E-Print Network [OSTI]

often live near active faults, because where there is a fault there is usually a water supply. And that means these places become part of major trade routes, like the Silk Roads across Asia from Xi urban building. What is even more frighten- ing is that in many parts of the world poor

Cipolla, Roberto

174

Fault Detection, Identification and Accommodation for an Electro-hydraulic  

E-Print Network [OSTI]

Fault Detection, Identification and Accommodation for an Electro-hydraulic System: An Adaptive in electro-hydraulic systems. It is well known fact that any realistic model of a hydraulic system suffers, such a scheme becomes a natural choice for designing robust fault detection algorithms for electro-hydraulic

Yao, Bin

175

Fuzzy Pattern Recognition Based Fault Diagnosis Rafik Bensaadi1  

E-Print Network [OSTI]

Fuzzy Pattern Recognition Based Fault Diagnosis Rafik Bensaadi1 , Leïla H. Mouss1 , Mohamed D in this paper the design of a Fuzzy Pattern Recognition System (FPRS) that solves, in real time, the main. Keywords: Diagnosis, fault detection, pattern recognition, fuzzy control, conjugate gradients, complex

Boyer, Edmond

176

Arcing fault in sub-distribution branch circuits  

SciTech Connect (OSTI)

It's well known the importance of short-circuit current evaluation for the design of any power system. Every system is subject to faults, moreover short-circuits and ground faults can be expected in any point. Even if the maximum and minimum values are generally defined with reference at a bolted-fault, bolted short-circuits are rare and the fault usually involves arcing and burning; particularly the limit value of minimum short-circuit depends really on arcing-fault. In earlier experimental investigations into the functional simulation of insulation loss, in branch circuit conductors, the authors chose to normalize the arcing-fault simulation to be used in laboratory tests. This conventional simulation allows characterization of this intrinsically random phenomenon by means of a probabilistic approach, in order to define in statistical terms the expected short circuit value. The authors examine more closely the arcing-fault in the design of sub distribution branch-circuits as weak points of the installation. In fact, what they propose are straightforward criteria, whether in the structure of the system or in the coordination of protection, which afford a more rational control on arcing-fault.

Parise, G.; Grasseli, U.; Luozzo, V. Di (Univ. di Roma, Rome (Italy). Dept. di Ingegneria Elettrica)

1993-04-01T23:59:59.000Z

177

Symbolic identification for fault detection in aircraft gas turbine engines  

E-Print Network [OSTI]

Symbolic identification for fault detection in aircraft gas turbine engines S Chakraborty, S Sarkar and computationally inexpensive technique of component-level fault detection in aircraft gas-turbine engines identification, gas turbine engines, language-theoretic analysis 1 INTRODUCTION The propulsion system of modern

Ray, Asok

178

Fault detection and diagnosis capabilities of test sequence selection  

E-Print Network [OSTI]

Review Fault detection and diagnosis capabilities of test sequence selection methods based on the FSM model T Ramalingam*, Anindya Dast and K ThuIasiraman* Different test sequence selection methods resolution in diagnosing the fault. The test sequence selection methods are then compared based on the length

Thulsiraman, Krishnaiyan

179

SEISMIC INVESTIGATION OF WRENCH FAULTING AND FRACTURING AT RULISON  

E-Print Network [OSTI]

to gas production at Rulison. Fracture zones are associated with fault trends and areas of deformation networks that help determine gas migration and accumulation. This thesis presents the characterization of the complex wrench fault network at Rulison Field, and its linkage to enhanced natural fracture zones. Rulison

180

All-to-all sequenced fault detection system  

DOE Patents [OSTI]

An apparatus, program product and method enable nodal fault detection by sequencing communications between all system nodes. A master node may coordinate communications between two slave nodes before sequencing to and initiating communications between a new pair of slave nodes. The communications may be analyzed to determine the nodal fault.

Archer, Charles Jens (Rochester, MN); Pinnow, Kurt Walter (Rochester, MN); Ratterman, Joseph D. (Rochester, MN); Smith, Brian Edward (Rochester, MN)

2010-11-02T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Automatic Fault Characterization via Abnormality-Enhanced Classification  

SciTech Connect (OSTI)

Enterprise and high-performance computing systems are growing extremely large and complex, employing hundreds to hundreds of thousands of processors and software/hardware stacks built by many people across many organizations. As the growing scale of these machines increases the frequency of faults, system complexity makes these faults difficult to detect and to diagnose. Current system management techniques, which focus primarily on efficient data access and query mechanisms, require system administrators to examine the behavior of various system services manually. Growing system complexity is making this manual process unmanageable: administrators require more effective management tools that can detect faults and help to identify their root causes. System administrators need timely notification when a fault is manifested that includes the type of fault, the time period in which it occurred and the processor on which it originated. Statistical modeling approaches can accurately characterize system behavior. However, the complex effects of system faults make these tools difficult to apply effectively. This paper investigates the application of classification and clustering algorithms to fault detection and characterization. We show experimentally that naively applying these methods achieves poor accuracy. Further, we design novel techniques that combine classification algorithms with information on the abnormality of application behavior to improve detection and characterization accuracy. Our experiments demonstrate that these techniques can detect and characterize faults with 65% accuracy, compared to just 5% accuracy for naive approaches.

Bronevetsky, G; Laguna, I; de Supinski, B R

2010-12-20T23:59:59.000Z

182

Fault Tolerant Oxygen Control of a Diesel Engine Air System  

E-Print Network [OSTI]

Fault Tolerant Oxygen Control of a Diesel Engine Air System Rainer Nitsche Matthias Bitzer control problem of a Diesel engine air system having a jammed Exhaust Gas Recirculation (EGR) valve of the air system. Keywords: Fault tolerant control, Diesel engine, Air system, Model-based trajectory

Paris-Sud XI, Université de

183

Online Fault Detection and Tolerance for Photovoltaic Energy Harvesting Systems  

E-Print Network [OSTI]

and weather conditions (e.g., clouds), and the output power of PV systems is directly dependent on solar and mitigate the output power shortage under low levels of solar irradiance. Moreover, PV panels exhibit highly fault detection and tolerance. Our fault detection and tolerance technique reduces output power

Pedram, Massoud

184

Using Reinforcement Learning for Proactive Network Fault Management  

E-Print Network [OSTI]

fault management demands intelligent man­ agement actions be taken by central manager or remote agents.g., alarms) which appear sequentially. For example, on the manager's side, polling devices randomly (orUsing Reinforcement Learning for Proactive Network Fault Management Qiming He, Mark A. Shayman

Shayman, Mark A.

185

Test generation and fault detection for VLSI PPL circuits  

SciTech Connect (OSTI)

The problem of design for testability of PPL logic circuits is addressed. A test-generation package was developed which utilizes the special features of PPL logic to generate high fault coverage test vectors at a reduced computational cost. The test strategy assumes that one of the scan design techniques is used. A new methodology for test-vectors compaction without compromising the fault coverage is also proposed. A fault-oriented test-generation algorithm combined with a heuristic test-generation algorithm are the essential ingredients of this package. The fault-oriented algorithm uses a modified D-algorithm which includes look-ahead features and a new seven-valued logic to improve the average speed of the test-generation process. Fault coverages in the 90% range were obtained using the test sequences generated by this package.

Amin, A.A.M.

1987-01-01T23:59:59.000Z

186

Clear Skies  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation Proposed New SubstationClean Communities of WesternVail Global Energy Forum Dr.2SitesA. A.

187

Find Clear  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Career Scientists'Montana.ProgramJulie A. Reddick|Document thatDepartmentEnergy ThisSomePhoto ofp

188

Acceleration and evolution of faults: An example from the Hunter MountainPanamint Valley fault zone, Eastern California  

E-Print Network [OSTI]

: R.D. van der Hilst Keywords: geodesy fault evolution InSAR rock mechanics Western United States assumes a monotonic increase in slip rate with time as the fault matures and straightens. The rate. However, before this can be realized, we need to better understand the various sources for discrepancies

Amelung, Falk

189

Boullier The fault zone geology 1 Fault zone geology: lessons from drilling through the Nojima and 1  

E-Print Network [OSTI]

drilling through the Nojima and 1 Chelungpu faults 2 3 Anne-Marie Boullier 4-Marie.Boullier@obs.ujf-grenoble.fr 8 9 Abstract 10 Several drilling projects have been conducted through significant topics 32 for future research, one of which was "fault zone drilling

Paris-Sud XI, Université de

190

Boullier The fault zone geology 1 Fault zone geology: lessons from drilling through the Nojima and 1  

E-Print Network [OSTI]

drilling through the Nojima and 1 Chelungpu faults 2 3 Anne-Marie Boullier 4-Marie.Boullier@obs.ujf-grenoble.fr 8 9 Abstract 10 Several drilling projects have been conducted through was "fault zone drilling combined with surface-based 33 geophysical and geological

Boyer, Edmond

191

Feb. 11, 2008 Advanced Fault Tolerance Solutions for High Performance Computing 1/47 Advanced Fault Tolerance Solutions  

E-Print Network [OSTI]

Feb. 11, 2008 Advanced Fault Tolerance Solutions for High Performance Computing 1/47 RAS RAS Advanced Fault Tolerance Solutions for High Performance Computing Christian Engelmann Oak Ridge National Solutions for High Performance Computing 2/47 · Nation's largest energy laboratory · Nation's largest

Engelmann, Christian

192

The effective delayed neutron fraction for bare-metal criticals  

SciTech Connect (OSTI)

Given sufficient material, a large number of actinides could be used to form bare-metal criticals. The effective delayed neutron fraction for a bare critical comprised of a fissile material is comparable with the absolute delayed neutron fraction. The effective delayed neutron fraction for a bare critical composed of a fissionable material is reduced by factors of 2 to 10 when compared with the absolute delayed neutron fraction. When the effective delayed neutron fraction is small, the difference between delayed and prompt criticality is small, and extreme caution must be used in critical assemblies of these materials. This study uses an approximate but realistic model to survey the actinide region to compare effective delayed neutron fractions with absolute delayed neutron fractions.

Pearlstein, S.

1999-12-01T23:59:59.000Z

193

A framework for delay emulation of large-scale internetworks  

E-Print Network [OSTI]

. The framework models and dynamically adapts the test traffic according to the network delay characteristics observed on the Internet in real-time. The proposed framework consists of three main modules: Virtual Host Configuration Module, Delay Estimator...

Venkata, Shravan Rangaraju

2001-01-01T23:59:59.000Z

194

Delay Analysis of Graphene Field-Effect Transistors  

E-Print Network [OSTI]

In this letter, we analyze the carrier transit delay in graphene field-effect transistors (GFETs).The extraction of the intrinsic delay provides a new way to directly estimate carrier velocity from the experimental data, ...

Wang, Han

195

High energy arcing fault fires in switchgear equipment : a literature review.  

SciTech Connect (OSTI)

In power generating plants, switchgear provide a means to isolate and de-energize specific electrical components and buses in order to clear downstream faults, perform routine maintenance, and replace necessary electrical equipment. These protective devices may be categorized by the insulating medium, such as air or oil, and are typically specified by voltage classes, i.e. low, medium, and high voltage. Given their high energy content, catastrophic failure of switchgear by means of a high energy arcing fault (HEAF) may occur. An incident such as this may lead to an explosion and fire within the switchgear, directly impact adjacent components, and possibly render dependent electrical equipment inoperable. Historically, HEAF events have been poorly documented and discussed in little detail. Recent incidents involving switchgear components at nuclear power plants, however, were scrupulously investigated. The phenomena itself is only understood on a very elementary level from preliminary experiments and theories; though many have argued that these early experiments were inaccurate due to primitive instrumentation or poorly justified methodologies and thus require re-evaluation. Within the past two decades, however, there has been a resurgence of research that analyzes previous work and modern technology. Developing a greater understanding of the HEAF phenomena, in particular the affects on switchgear equipment and other associated switching components, would allow power generating industries to minimize and possibly prevent future occurrences, thereby reducing costs associated with repair and downtime. This report presents the findings of a literature review focused on arc fault studies for electrical switching equipment. The specific objective of this review was to assess the availability of the types of information needed to support development of improved treatment methods in fire Probabilistic Risk Assessment (PRA) for nuclear power plant applications.

Nowlen, Steven Patrick; Brown, Jason W.; Wyant, Francis John

2008-10-01T23:59:59.000Z

196

q-deformed logistic map with delay feedback  

E-Print Network [OSTI]

The delay logistic map with two types of q-deformations: Tsallis and Quantum-group type are studied. The stability of the map and its bifurcation scheme is analyzed as a function of the deformation and delay feedback parameters. Chaos is suppressed in a certain region of deformation and feedback parameter space. The steady state obtained by delay feedback is maintained in one type of deformation while chaotic behavior is recovered in another type with increasing delay.

Manish Dev Shrimali; Subhashish Banerjee

2012-03-14T23:59:59.000Z

197

SRS delayed neutron instruments for safeguards measurements  

SciTech Connect (OSTI)

Six analytical systems measuring delayed neutrons have been used for safeguards measurements at the Savannah River Site (SRS). A predecessor, the 252Cf Activation Analysis Facility installed at the Savannah River Technology Center (formally SR Laboratory) has been used since 1974 to analyze small samples, measuring both delayed neutrons and gammas. The six shufflers, plus one currently being fabricated, were developed, designed and fabricated by the LANL N-1 group. These shufflers have provided safeguards measurements of product (2 each), in-process scrap (2 each plus a conceptual replacement) and process waste (2 each plus one being fabricated). One shuffler for scrap assay was the first shuffler to be installed (1978) in a process. Another (waste) was the first installed in a process capable of assaying barrels. A third (waste) is the first pass-through model and a fourth (product) is the most precise ({+-}.12%) and accurate NDA instrument yet produced.

Studley, R.V. [Westinghouse SRC, Aiken, SC (United States)

1993-12-31T23:59:59.000Z

198

Coherence delay augmented laser beam homogenizer  

DOE Patents [OSTI]

The geometrical restrictions on a laser beam homogenizer are relaxed by ug a coherence delay line to separate a coherent input beam into several components each having a path length difference equal to a multiple of the coherence length with respect to the other components. The components recombine incoherently at the output of the homogenizer, and the resultant beam has a more uniform spatial intensity suitable for microlithography and laser pantogography. Also disclosed is a variable aperture homogenizer, and a liquid filled homogenizer.

Rasmussen, P.; Bernhardt, A.

1993-06-29T23:59:59.000Z

199

Method for reducing ignition delay of fuels  

SciTech Connect (OSTI)

A method of reducing ignition delay /tau/, of fuels to negligible values and negligible differences is disclosed. Fuels conditioned to have such negligible values and differences are readily used in multiple fuel engines, such fuels self-ignite substantially instantaneously when injected into an oxidant, require substantially no heat transfer from the oxidant to effect the self-ignition, and the self-ignition is sufficient to sustain continued combustion.

Hoppie, L.O.

1984-05-15T23:59:59.000Z

200

Coherence delay augmented laser beam homogenizer  

DOE Patents [OSTI]

The geometrical restrictions on a laser beam homogenizer are relaxed by ug a coherence delay line to separate a coherent input beam into several components each having a path length difference equal to a multiple of the coherence length with respect to the other components. The components recombine incoherently at the output of the homogenizer, and the resultant beam has a more uniform spatial intensity suitable for microlithography and laser pantogography. Also disclosed is a variable aperture homogenizer, and a liquid filled homogenizer.

Rasmussen, Paul (Livermore, CA); Bernhardt, Anthony (Berkeley, CA)

1993-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

E-Print Network 3.0 - activation delay time Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Activity Analysis and PreLayout Activity Prediction for FPGAs Summary: activity on a net changes when delays are zero (zero delay activity) versus when logic delays... are...

202

State Control Design for Linear Systems with Distributed Time Delays  

E-Print Network [OSTI]

State Control Design for Linear Systems with Distributed Time Delays Daniel Gontkovic and Róbert with distributed time delays. Using an extended form of the Lyapunov- Krasovskii functional the controller design involving distributed time delays is a problem of large practical interest where intensive activity are done

Paris-Sud XI, Université de

203

Maximizing Crosstalk-Induced Slowdown During Path Delay Test  

E-Print Network [OSTI]

in path delay for c5315 .................................................................... 57 Figure 11 Increase in path delay for c2670 .................................................................... 60 Figure 12 Increase in path delay for c... for critical paths considering single aggressor crosstalk effect with due consideration to the timing alignment and direction. This method has similar CPU efficiency to that of [17] and [18]. However, they did not take into account the possible impact...

Gope, Dibakar

2012-10-19T23:59:59.000Z

204

Steps toward fault-tolerant quantum chemistry.  

SciTech Connect (OSTI)

Developing quantum chemistry programs on the coming generation of exascale computers will be a difficult task. The programs will need to be fault-tolerant and minimize the use of global operations. This work explores the use a task-based model that uses a data-centric approach to allocate work to different processes as it applies to quantum chemistry. After introducing the key problems that appear when trying to parallelize a complicated quantum chemistry method such as coupled-cluster theory, we discuss the implications of that model as it pertains to the computational kernel of a coupled-cluster program - matrix multiplication. Also, we discuss the extensions that would required to build a full coupled-cluster program using the task-based model. Current programming models for high-performance computing are fault-intolerant and use global operations. Those properties are unsustainable as computers scale to millions of CPUs; instead one must recognize that these systems will be hierarchical in structure, prone to constant faults, and global operations will be infeasible. The FAST-OS HARE project is introducing a scale-free computing model to address these issues. This model is hierarchical and fault-tolerant by design, allows for the clean overlap of computation and communication, reducing the network load, does not require checkpointing, and avoids the complexity of many HPC runtimes. Development of an algorithm within this model requires a change in focus from imperative programming to a data-centric approach. Quantum chemistry (QC) algorithms, in particular electronic structure methods, are an ideal test bed for this computing model. These methods describe the distribution of electrons in a molecule, which determine the properties of the molecule. The computational cost of these methods is high, scaling quartically or higher in the size of the molecule, which is why QC applications are major users of HPC resources. The complexity of these algorithms means that MPI alone is insufficient to achieve parallel scaling; QC developers have been forced to use alternative approaches to achieve scalability and would be receptive to radical shifts in the programming paradigm. Initial work in adapting the simplest QC method, Hartree-Fock, to this the new programming model indicates that the approach is beneficial for QC applications. However, the advantages to being able to scale to exascale computers are greatest for the computationally most expensive algorithms; within QC these are the high-accuracy coupled-cluster (CC) methods. Parallel coupledcluster programs are available, however they are based on the conventional MPI paradigm. Much of the effort is spent handling the complicated data dependencies between the various processors, especially as the size of the problem becomes large. The current paradigm will not survive the move to exascale computers. Here we discuss the initial steps toward designing and implementing a CC method within this model. First, we introduce the general concepts behind a CC method, focusing on the aspects that make these methods difficult to parallelize with conventional techniques. Then we outline what is the computational core of the CC method - a matrix multiply - within the task-based approach that the FAST-OS project is designed to take advantage of. Finally we outline the general setup to implement the simplest CC method in this model, linearized CC doubles (LinCC).

Taube, Andrew Garvin

2010-05-01T23:59:59.000Z

205

Self field triggered superconducting fault current limiter  

DOE Patents [OSTI]

A superconducting fault current limiter array with a plurality of superconductor elements arranged in a meanding array having an even number of supconductors parallel to each other and arranged in a plane that is parallel to an odd number of the plurality of superconductors, where the odd number of supconductors are parallel to each other and arranged in a plane that is parallel to the even number of the plurality of superconductors, when viewed from a top view. The even number of superconductors are coupled at the upper end to the upper end of the odd number of superconductors. A plurality of lower shunt coils each coupled to the lower end of each of the even number of superconductors and a plurality of upper shunt coils each coupled to the upper end of each of the odd number of superconductors so as to generate a generally orthoganal uniform magnetic field during quenching using only the magenetic field generated by the superconductors.

Tekletsadik, Kasegn D. (Rexford, NY)

2008-02-19T23:59:59.000Z

206

Locating hardware faults in a parallel computer  

DOE Patents [OSTI]

Locating hardware faults in a parallel computer, including defining within a tree network of the parallel computer two or more sets of non-overlapping test levels of compute nodes of the network that together include all the data communications links of the network, each non-overlapping test level comprising two or more adjacent tiers of the tree; defining test cells within each non-overlapping test level, each test cell comprising a subtree of the tree including a subtree root compute node and all descendant compute nodes of the subtree root compute node within a non-overlapping test level; performing, separately on each set of non-overlapping test levels, an uplink test on all test cells in a set of non-overlapping test levels; and performing, separately from the uplink tests and separately on each set of non-overlapping test levels, a downlink test on all test cells in a set of non-overlapping test levels.

Archer, Charles J.; Megerian, Mark G.; Ratterman, Joseph D.; Smith, Brian E.

2010-04-13T23:59:59.000Z

207

E-Print Network 3.0 - all-around cleared issue Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

world... -reviewed journal, Australian Feminist Studies is proud to sustain a clear political commitment to feminist teaching... , that contribute to current developments and...

208

Can We Observe Galaxies that Recede Faster than Light ? -- A More Clear-Cut Answer  

E-Print Network [OSTI]

A more clear-cut answer to the title question is, ``Yes'' if the universal expansion started with a big bang; ``No'' if it started infinitely slowly.

T. Kiang

2003-05-27T23:59:59.000Z

209

Regime Security Theory: Why Do States With No Clear Strategic Security Concerns Obtain Nuclear Weapons? .  

E-Print Network [OSTI]

??Current realist explanations of why states decide to develop nuclear weapons cannot account for the behavior of states that lack a clear strategic threat. An… (more)

Beasley, Matthew

2009-01-01T23:59:59.000Z

210

Logic gates at the surface code threshold: Superconducting qubits poised for fault-tolerant quantum computing  

E-Print Network [OSTI]

A quantum computer can solve hard problems - such as prime factoring, database searching, and quantum simulation - at the cost of needing to protect fragile quantum states from error. Quantum error correction provides this protection, by distributing a logical state among many physical qubits via quantum entanglement. Superconductivity is an appealing platform, as it allows for constructing large quantum circuits, and is compatible with microfabrication. For superconducting qubits the surface code is a natural choice for error correction, as it uses only nearest-neighbour coupling and rapidly-cycled entangling gates. The gate fidelity requirements are modest: The per-step fidelity threshold is only about 99%. Here, we demonstrate a universal set of logic gates in a superconducting multi-qubit processor, achieving an average single-qubit gate fidelity of 99.92% and a two-qubit gate fidelity up to 99.4%. This places Josephson quantum computing at the fault-tolerant threshold for surface code error correction. Our quantum processor is a first step towards the surface code, using five qubits arranged in a linear array with nearest-neighbour coupling. As a further demonstration, we construct a five-qubit Greenberger-Horne-Zeilinger (GHZ) state using the complete circuit and full set of gates. The results demonstrate that Josephson quantum computing is a high-fidelity technology, with a clear path to scaling up to large-scale, fault-tolerant quantum circuits.

R. Barends; J. Kelly; A. Megrant; A. Veitia; D. Sank; E. Jeffrey; T. C. White; J. Mutus; A. G. Fowler; B. Campbell; Y. Chen; Z. Chen; B. Chiaro; A. Dunsworth; C. Neill; P. O`Malley; P. Roushan; A. Vainsencher; J. Wenner; A. N. Korotkov; A. N. Cleland; John M. Martinis

2014-02-19T23:59:59.000Z

211

Development of Characterization Technology for Fault Zone Hydrology  

SciTech Connect (OSTI)

Several deep trenches were cut, and a number of geophysical surveys were conducted across the Wildcat Fault in the hills east of Berkeley, California. The Wildcat Fault is believed to be a strike-slip fault and a member of the Hayward Fault System, with over 10 km of displacement. So far, three boreholes of ~;; 150m deep have been core-drilled and borehole geophysical logs were conducted. The rocks are extensively sheared and fractured; gouges were observed at several depths and a thick cataclasitic zone was also observed. While confirming some earlier, published conclusions from shallow observations about Wildcat, some unexpected findings were encountered. Preliminary analysis indicates that Wildcat near the field site consists of multiple faults. The hydraulic test data suggest the dual properties of the hydrologic structure of the fault zone. A fourth borehole is planned to penetrate the main fault believed to lie in-between the holes. The main philosophy behind our approach for the hydrologic characterization of such a complex fractured system is to let the system take its own average and monitor a long term behavior instead of collecting a multitude of data at small length and time scales, or at a discrete fracture scale and to ?up-scale,? which is extremely tenuous.

Karasaki, Kenzi; Onishi, Tiemi; Gasperikova, Erika; Goto, Junichi; Tsuchi, Hiroyuki; Miwa, Tadashi; Ueta, Keiichi; Kiho, Kenzo; MIyakawa, Kimio

2010-08-06T23:59:59.000Z

212

THE STRUCTURE OF THE BROAD-LINE REGION IN ACTIVE GALACTIC NUCLEI. I. RECONSTRUCTED VELOCITY-DELAY MAPS  

SciTech Connect (OSTI)

We present velocity-resolved reverberation results for five active galactic nuclei. We recovered velocity-delay maps using the maximum entropy method for four objects: Mrk 335, Mrk 1501, 3C 120, and PG 2130+099. For the fifth, Mrk 6, we were only able to measure mean time delays in different velocity bins of the H{beta} emission line. The four velocity-delay maps show unique dynamical signatures for each object. For 3C 120, the Balmer lines show kinematic signatures consistent with both an inclined disk and infalling gas, but the He II {lambda}4686 emission line is suggestive only of inflow. The Balmer lines in Mrk 335, Mrk 1501, and PG 2130+099 show signs of infalling gas, but the He II emission in Mrk 335 is consistent with an inclined disk. We also see tentative evidence of combined virial motion and infalling gas from the velocity-binned analysis of Mrk 6. The maps for 3C 120 and Mrk 335 are two of the most clearly defined velocity-delay maps to date. These maps constitute a large increase in the number of objects for which we have resolved velocity-delay maps and provide evidence supporting the reliability of reverberation-based black hole mass measurements.

Grier, C. J.; Peterson, B. M.; Pogge, R. W.; De Rosa, G.; Martini, Paul; Kochanek, C. S.; Zu, Y.; Shappee, B.; Beatty, T. G.; Salvo, C. Araya; Bird, J. C. [Department of Astronomy, The Ohio State University, 140 W 18th Ave, Columbus, OH 43210 (United States)] [Department of Astronomy, The Ohio State University, 140 W 18th Ave, Columbus, OH 43210 (United States); Horne, Keith [SUPA Physics and Astronomy, University of St. Andrews, Fife, KY16 9SS Scotland (United Kingdom)] [SUPA Physics and Astronomy, University of St. Andrews, Fife, KY16 9SS Scotland (United Kingdom); Bentz, M. C. [Department of Physics and Astronomy, Georgia State University, Astronomy Offices, One Park Place South SE, Suite 700, Atlanta, GA 30303 (United States)] [Department of Physics and Astronomy, Georgia State University, Astronomy Offices, One Park Place South SE, Suite 700, Atlanta, GA 30303 (United States); Denney, K. D. [Marie Curie Fellow at the Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, DK-2100 Copenhagen (Denmark)] [Marie Curie Fellow at the Dark Cosmology Centre, Niels Bohr Institute, University of Copenhagen, Juliane Maries Vej 30, DK-2100 Copenhagen (Denmark); Siverd, R. [Department of Physics and Astronomy, Vanderbilt University, 5301 Stevenson Center, Nashville, TN 37235 (United States)] [Department of Physics and Astronomy, Vanderbilt University, 5301 Stevenson Center, Nashville, TN 37235 (United States); Sergeev, S. G.; Borman, G. A. [Crimean Astrophysical Observatory, P/O Nauchny Crimea 98409 (Ukraine)] [Crimean Astrophysical Observatory, P/O Nauchny Crimea 98409 (Ukraine); Kaspi, S. [School of Physics and Astronomy, Raymond and Beverly Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978 (Israel)] [School of Physics and Astronomy, Raymond and Beverly Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978 (Israel); Bord, D. J. [Department of Natural Sciences, The University of Michigan - Dearborn, 4901 Evergreen Rd, Dearborn, MI 48128 (United States)] [Department of Natural Sciences, The University of Michigan - Dearborn, 4901 Evergreen Rd, Dearborn, MI 48128 (United States); Che, X. [Department of Astronomy, University of Michigan, 500 Church Street, Ann Arbor, MI 41809 (United States)] [Department of Astronomy, University of Michigan, 500 Church Street, Ann Arbor, MI 41809 (United States); and others

2013-02-10T23:59:59.000Z

213

Visualization of stacking faults in fcc crystals in plastic deformations  

E-Print Network [OSTI]

Using molecular dynamics simulation, we investigate the dynamics of stacking faults in fcc crystals in uniaxial stretching in a Lennard-Jones binary mixture composed of 4096 particles in three dimensions. We visualize stacking faults using a disorder variable $D_j(t)$ for each particle $j$ constructed from local bond order parameters based on spherical harmonics (Steinhardt order parameters). Also introducing a method of bond breakage, we examine how stacking faults are formed and removed by collective particle motions. These processes are relevant in plasticity of fcc crystals.

Takeshi Kawasaki; Akira Onuki

2011-11-27T23:59:59.000Z

214

Fault-tree construction and calculations on a microcomputer  

E-Print Network [OSTI]

Figure 17 - Program Overview Screen Figure 18 ? Main Menu Screen Figure 19 ? Invalid Command Screen Figure 20 - First Usage of Disk Screen Figure 21 ? Fault-tree Name Screen Figure 22 - Invalid Fault-tree Name Screen Fi gure 23 ? TOP EVENT Label... to do? Fi gure 19. Inval i d Command Screen 53 CREATE - This command allows the user to build a new fault tree. After a CREATE command is entered, the system wi 1 1 display the screen in Figure 20. This question is asked in order to determine...

Beckmann, Jeffery Linn

1985-01-01T23:59:59.000Z

215

Experimental characterization of faults on low-voltage systems  

E-Print Network [OSTI]

arcing ground faults '10'. The first scheme is very similar to the Ground Sensor Protection scheme described in i8j. The second scheme employs the fact that the voltage waveshape at the 1'suit point is flat topped. Harmonic analysis shows that... value when an arcing fault takes place. Continued presence of a, relatively high third- harmonic component in the bus voltage is a definite sign that there is an arcing fault in the system, Kusko and Peeran recommended the use of a, third harmonic...

Ahmed, Jubayer

1992-01-01T23:59:59.000Z

216

On-Line Fault Detection and Compensation of Hydraulic Driven Machines Using Modelling Techniques  

E-Print Network [OSTI]

On-Line Fault Detection and Compensation of Hydraulic Driven Machines Using Modelling Techniques C purpose of hydraulic driven machines as well as for the compensation of incipient faults where applicable: Modelling, Simulation, Hydraulic motors, Fault detection, Fault Compensation 1. Introduction Model

Thawonmas, Ruck

217

Thermal anomalies indicate preferential flow along faults in unconsolidated sedimentary aquifers  

E-Print Network [OSTI]

Thermal anomalies indicate preferential flow along faults in unconsolidated sedimentary aquifers V in unconsolidated siliciclastic aquifers off-set by normal-faults in the Lower Rhine Embayment, Germany. High plane. Most current models of fault hydrology in unconsolidated sedimentary sequences assume faults

Bense, Victor

218

Geometry and scaling relations of a population of very small rift-related normal faults  

E-Print Network [OSTI]

normal faults within the Solite Quarry of the Dan River rift basin range in length from a few millimetres AND SCALING RELATIONS The small normal faults are present in quarries of the Virginia Solite Corporation outcrops and quarried boulders (Fig. 2). The fault traces are typically straight, although the fault tips

219

Analysis of the growth of strike-slip faults using effective medium theory  

SciTech Connect (OSTI)

Increases in the dimensions of strike-slip faults including fault length, thickness of fault rock and the surrounding damage zone collectively provide quantitative definition of fault growth and are commonly measured in terms of the maximum fault slip. The field observations indicate that a common mechanism for fault growth in the brittle upper crust is fault lengthening by linkage and coalescence of neighboring fault segments or strands, and fault rock-zone widening into highly fractured inner damage zone via cataclastic deformation. The most important underlying mechanical reason in both cases is prior weakening of the rocks surrounding a fault's core and between neighboring fault segments by faulting-related fractures. In this paper, using field observations together with effective medium models, we analyze the reduction in the effective elastic properties of rock in terms of density of the fault-related brittle fractures and fracture intersection angles controlled primarily by the splay angles. Fracture densities or equivalent fracture spacing values corresponding to the vanishing Young's, shear, and quasi-pure shear moduli were obtained by extrapolation from the calculated range of these parameters. The fracture densities or the equivalent spacing values obtained using this method compare well with the field data measured along scan lines across the faults in the study area. These findings should be helpful for a better understanding of the fracture density/spacing distribution around faults and the transition from discrete fracturing to cataclastic deformation associated with fault growth and the related instabilities.

Aydin, A.; Berryman, J.G.

2009-10-15T23:59:59.000Z

220

Delay time and Hartman effect in strain engineered graphene  

SciTech Connect (OSTI)

Tunneling times, including group delay and dwell time, are studied for massless Dirac electrons transmitting through a one-dimensional barrier in strain-engineered graphene. The Hartman effect, the independence of group delay on barrier length, is induced by the strain effect, and associated with the transmission gap and the evanescent mode. The influence of barrier height/length and strain modulus/direction on the group delay is also discussed, which provides the flexibility to control the group delay with applications in graphene-based devices. The relationship between group delay and dwell time is finally derived to clarify the nature of the Hartman effect.

Chen, Xi, E-mail: xchen@shu.edu.cn; Deng, Zhi-Yong [Department of Physics, Shanghai University, 200444 Shanghai (China); Ban, Yue, E-mail: yban@shu.edu.cn [Department of Electronic Information Materials, Shanghai University, 200444 Shanghai (China)

2014-05-07T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Short Channel Amorphous-Silicon TFT's on High-Temperature Clear Plastic Substrates  

E-Print Network [OSTI]

Short Channel Amorphous-Silicon TFT's on High-Temperature Clear Plastic Substrates K. Long, H@princeton.edu To achieve light-weight flexible AMOLED displays on plastic substrates, the substratesmust be optically clear for plastic. High-temperature plastics such as polyimide (e.g. KaptonB E) have a glass transition temperature

222

CO2 Efflux from Cleared Mangrove Peat Catherine E. Lovelock1  

E-Print Network [OSTI]

CO2 Efflux from Cleared Mangrove Peat Catherine E. Lovelock1 *, Roger W. Ruess2 , Ilka C. Feller3 1 on the islands of Twin Cays, Belize. We also disturbed these cleared peat soils to assess what disturbance. Disturbing peat leads to short term increases in CO2 efflux (27 umol m22 s21 ), but this had returned

Ruess, Roger W.

223

Introduction Be brief. State your major idea, hypothesis or claim clearly with as  

E-Print Network [OSTI]

qualification as possible. Provide the minimum of background information needed by a reader to understand why claim, main point clearly and with as little qualification as you can. A clear statement of your of important piece of equipment, or perhaps a flow chart summarizing experimental design. Scanned, hand- drawn

Texas at Arlington, University of

224

Automated transmission line fault analysis using synchronized sampling at two ends  

SciTech Connect (OSTI)

This paper introduces a new approach to fault analysis using synchronized sampling. A digital fault recorder with Global Positioning System (GPS) satellite receiver is the source of data for this approach. Fault analysis functions, such as fault detection, classification and location are implemented for a transmission line using synchronized samples from two ends of a line. This technique can be extremely fast, selective and accurate, providing fault analysis performance that can not easily be matched by other known techniques.

Kezunovic, M. [Texas A and M Univ., College Station, TX (United States)] [Texas A and M Univ., College Station, TX (United States); Perunicic, B. [Lamar Univ., Beaumont, TX (United States)] [Lamar Univ., Beaumont, TX (United States)

1996-02-01T23:59:59.000Z

225

Automated transmission line fault analysis using synchronized sampling at two ends  

SciTech Connect (OSTI)

This paper introduces a new approach to fault analysis using synchronized sampling. A digital fault recorder with Global Positioning System (GPS) satellite receiver is the source of data for this approach. Fault analysis functions, such as fault detection, classification and location are implemented for a transmission line using synchronized samples from two ends of a line. This technique can be extremely fast, selective and accurate, providing fault analysis performance that can not easily be matched by other known techniques.

Kezunovic, M. [Texas A and M Univ., College Station, TX (United States); Perunicic, B. [Lamar Univ., Beaumont, TX (United States)

1995-12-31T23:59:59.000Z

226

Evaluation of a Decoupling-Based Fault Detection and Diagnostic Technique - Part I: Field Emulation Evaluation  

E-Print Network [OSTI]

), evaporator fouling (Evapfoul), liquid-line restriction (Llrestr), low refrigerant charge (Reflow), and refrigerant high charge (Refhigh). Except for refrigerant charge and compressor leakage faults for which five fault levels were introduced, four fault... for these tests. The method could detect low refrigerant charge and loss of compressor performance at the lowest levels introduced and all other faults at the second level. All of the faults could be reliably diagnosed before a 5% degradation in capacity...

Li, H.; Braun, J.

2006-01-01T23:59:59.000Z

227

arcing fault fires: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

stacking faults at a production-rate of few gmin. A guideline for controlling the number of layers of such FLG has also been suggested. Karmakar, Soumen; Lalla, Niranjan P;...

228

assembly line fault: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

of fault data to verify that all elements of the protection system Siegel, Mel 190 Bucket brigades on in-tree assembly networks John J. Bartholdi III a,*, Donald D. Eisenstein...

229

Microgrid Fault Protection Based on Symmetrical and Differential Current Components  

E-Print Network [OSTI]

Microgrid Fault Protection Based on Symmetrical and Differential Current Components Prepared.........................................................................................8 2. AEP CERTS MICROGRID .........................................................................9 ........................................................................67 #12;3 Index of Figures Figure 1: Schematic representation of the AEP CERTS microgrid

230

Characteristics of Wind Turbines Under Normal and Fault Conditions: Preprint  

SciTech Connect (OSTI)

This paper investigates the characteristics of a variable-speed wind turbine connected to a stiff or weak grid under normal and fault conditions and the role of reactive power compensation.

Muljadi, E.; Butterfield, C. P.; Parsons, B.; Ellis, A.

2007-02-01T23:59:59.000Z

231

Faults as potential hydrocarbon barriers, Arroyo Grande, California  

E-Print Network [OSTI]

Faulting in a sandstone introduces properties which are different from the country rock. Previous work has shown that these new properties can significantly impede the flow of hydrocarbons through the country rock. This thesis seeks to analyze...

Switek, Daniel Paul

1994-01-01T23:59:59.000Z

232

An information model for inter-organizational fault Patricia Marcu  

E-Print Network [OSTI]

in the IT Infrastructure Library (ITIL) [2] and related frameworks in the area of IT service management (ITSM). But since ITIL and the related ITSM frameworks do not consider specific aspects of inter- organizational (fault

233

Understanding Fault Characteristics And Sediment Depth For Geothermal...  

Open Energy Info (EERE)

Fault Characteristics And Sediment Depth For Geothermal Exploration Using 3D Gravity Inversion In Walker Valley, Nevada Jump to: navigation, search OpenEI Reference LibraryAdd to...

234

Non-intrusive fault detection in reciprocating compressors  

E-Print Network [OSTI]

This thesis presents a set of techniques for non-intrusive sensing and fault detection in reciprocating compressors driven by induction motors. The procedures developed here are "non-intrusive" because they rely only on ...

Schantz, Christopher James

2011-01-01T23:59:59.000Z

235

CAPRI : a common architecture for distributed probabilistic Internet fault diagnosis  

E-Print Network [OSTI]

This thesis presents a new approach to root cause localization and fault diagnosis in the Internet based on a Common Architecture for Probabilistic Reasoning in the Internet (CAPRI) in which distributed, heterogeneous ...

Lee, George J. (George Janbing), 1979-

2007-01-01T23:59:59.000Z

236

CAPRI: A Common Architecture for Distributed Probabilistic Internet Fault Diagnosis  

E-Print Network [OSTI]

This thesis presents a new approach to root cause localization and fault diagnosis in the Internet based on a Common Architecture for Probabilistic Reasoning in the Internet (CAPRI) in which distributed, heterogeneous ...

Lee, George J.

2007-06-04T23:59:59.000Z

237

Lossless fault-tolerant data structures with additive overhead  

E-Print Network [OSTI]

We develop the first dynamic data structures that tolerate ? memory faults, lose no data, and incur only an O(? ) additive overhead in overall space and time per operation. We obtain such data structures for arrays, linked ...

Christiano, Paul F.

238

anatolian fault zone: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

across the Mudurnu segment of the North Anatolian Fault Zone (NAFZ) in northwestern Turkey Ben-Zion, Yehuda 2 Velocity contrast across the 1944 rupture zone of the North...

239

STRESS AND FAULTING IN THE COSO GEOTHERMAL FIELD: UPDATE AND...  

Open Energy Info (EERE)

FLANK AND COSO WASH Jump to: navigation, search OpenEI Reference LibraryAdd to library Conference Proceedings: STRESS AND FAULTING IN THE COSO GEOTHERMAL FIELD: UPDATE AND...

240

Identifying Efficiency Degrading Faults in Split Air Conditioning Systems  

E-Print Network [OSTI]

Studies estimate that as much as 50% of packaged air conditioning systems operate in faulty conditions that degrade system efficiency. Common faults include: under- and over-charged systems (too much or too little refrigerant), faulty expansions...

Terrill, T. J.; Brown, M. L.; Cheyne, R. W. Jr.; Cousins, A. J.; Daniels, B. P.; Erb, K. L.; Garcia, P. A.; Leutermann, M. J.; Nel, A. J.; Robert, C. L.; Widger, S. B.; Williams, A. G.; Rasmussen, B. P.

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

The northwest extension of the Meers Fault in southwestern Oklahoma  

E-Print Network [OSTI]

THE NORTHWEST EXTENSION OF THE MEERS FAULT IN SOUTIRVESTERN OKLAHOMA A Thesis by HASAN CETIN Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE... May 1991 Major Subject: Geology THE NORTHWEST EXTENSION OF THE MEERS FAULT IN SOUTHWESTERN OKLAHOMA A Thesis by HASAN CETIN Approved as to style and content by: Norman R. ford (Chair of ommittee) Chr stopher C. Mathewson (Member) ne A...

Cetin, Hasan

1991-01-01T23:59:59.000Z

242

Two Similarity Measure Approaches to Whole Building Fault Diagnosis  

E-Print Network [OSTI]

consumption in buildings using similarity measures. The method is referred to as the cosine similarity method if cosine similarity is adopted and is referred to as the Euclidean distance similarity method if Euclidean distance similarity is implemented.... Fig. 1 Block diagram for diagnosing abnormal energy consumption Step 1: Reference Control Change Library Determination Whole building fault diagnosis is different from component level fault diagnosis. It can only give a general clue, for example...

Lin, G.; Claridge, D.

2012-01-01T23:59:59.000Z

243

The application of satellite time references to HVDC fault location  

SciTech Connect (OSTI)

An HVdc fault location scheme is described which relies on very precise detection of the time of arrival of fault created surges at both ends of the line. Such detection is achieved by a very accurate data acquisition and processing system combined with the time reference signals provided by a global positioning system receiver. Extensive digital simulation is carried out to determine the voltage and current waveforms, to identify the main sources of error and suggest possible compensation techniques.

Dewe, M.B.; Sankar, S.; Arrillaga, J. (Univ. of Canterbury, Christchurch (New Zealand))

1993-07-01T23:59:59.000Z

244

Occupancy Based Fault Detection on Building Level - a Feasibility Study  

E-Print Network [OSTI]

-going commissioning and fault detection and diagnostics (FDD) has been performed to improve the current situation of building problems by comparing measured building performance with design predictions [Portland 2003]. For fault detection, different methods... conference on building commissioning, Portland Energy Conservation. Portland. 2003. Methods for automated and continuous commissioning of building systems. US department of commerce, Portland energy conservation inc. Schijndel, A.W.M. van, 2008...

Tuip, B.; Houten, M.; Trcka, M.; Hensen, M.

2010-01-01T23:59:59.000Z

245

Fundamentals of Delayed Coking Joint Industry Project  

SciTech Connect (OSTI)

Delayed coking evolved steadily over the early to mid 1900s to enable refiners to convert high boiling, residual petroleum fractions to light products such as gasoline. Pound for pound, coking is the most energy intensive of any operation in a modern refinery. Large amounts of energy are required to heat the thick, poor-quality petroleum residuum to the 900 to 950 degrees F required to crack the heavy hydrocarbon molecules into lighter, more valuable products. One common misconception of delayed coking is that the product coke is a disadvantage. Although coke is a low valued (near zero economic value) byproduct, compared to transportation fuels, there is a significant worldwide trade and demand for coke as it is an economical fuel. Coke production has increased steadily over the last ten years, with further increases forecast for the foreseeable future. Current domestic production is near 111,000 tons per day. A major driving force behind this increase is the steady decline in crude quality available to refiners. Crude slates are expected to grow heavier with higher sulfur contents while environmental restrictions are expected to significantly reduce the demand for high-sulfur residual fuel oil. Light sweet crudes will continue to be available and in even greater demand than they are today. Refiners will be faced with the choice of purchasing light sweet crudes at a premium price, or adding bottom of the barrel upgrading capability, through additional new investments, to reduce the production of high-sulfur residual fuel oil and increase the production of low-sulfur distillate fuels. A second disadvantage is that liquid products from cokers frequently are unstable, i.e., they rapidly form gum and sediments. Because of intermediate investment and operating costs, delayed coking has increased in popularity among refiners worldwide. Based on the 2000 Worldwide Refining Survey published in the Oil and Gas, the delayed coking capacity for 101 refineries around the world is 2,937,439 barrels/calendar day. These cokers produce 154,607 tons of coke per day and delayed coking accounts for 88% of the world capacity. The delayed coking charge capacity in the United States is 1,787,860 b/cd. Despite its wide commercial use, only relatively few contractors and refiners are truly knowledgeable in delayed-coking design, so that this process carries with it a ''black art'' connotation. Until recently, the expected yield from cokers was determined by a simple laboratory test on the feedstock. As a result of Tulsa University's prior related research, a process model was developed that with additional work could be used to optimize existing delayed cokers over a wide range of potential feedstocks and operating conditions. The objectives of this research program are to: utilize the current micro, batch and pilot unit facilities at The University of Tulsa to enhance the understanding of the coking process; conduct additional micro and pilot unit tests with new and in-house resids and recycles to make current optimization models more robust; conduct focused kinetic experiments to enhance the furnace tube model and to enhance liquid production while minimizing sulfur in the products; conduct detailed foaming studies to optimize the process and minimize process upsets; quantify the parameters that affect coke morphology; and to utilize the knowledge gained from the experimental and modeling studies to enhance the computer programs developed in the previous JIP for optimization of the coking process. These refined computer models will then be tested against refinery data provided by the member companies. Novel concepts will also be explored for hydrogen sulfide removal of furnace gases as well as gas injection studies to reduce over-cracking. The following deliverables are scheduled from the two projects of the three-year JIP: (1) A novel method for enhancing liquid yields from delayed cokers and data that provide insight as to the optimum temperature to remove hydrogen sulfide from furnace gases. (2) An understanding of what causes foaming in c

Michael Volk Jr; Keith Wisecarver

2005-10-01T23:59:59.000Z

246

Microcomputer applications of, and modifications to, the modular fault trees  

SciTech Connect (OSTI)

The LaSalle Probabilistic Risk Assessment was the first major application of the modular logic fault trees after the IREP program. In the process of performing the analysis, many errors were discovered in the fault tree modules that led to difficulties in combining the modules to form the final system fault trees. These errors are corrected in the revised modules listed in this report. In addition, the application of the modules in terms of editing them and forming them into the system fault trees was inefficient. Originally, the editing had to be done line by line and no error checking was performed by the computer. This led to many typos and other logic errors in the construction of the modular fault tree files. Two programs were written to help alleviate this problem: (1) MODEDIT - This program allows an operator to retrieve a file for editing, edit the file for the plant specific application, perform some general error checking while the file is being modified, and store the file for later use, and (2) INDEX - This program checks that the modules that are supposed to form one fault tree all link up appropriately before the files are,loaded onto the mainframe computer. Lastly, the modules were not designed for relay type logic common in BWR designs but for solid state type logic. Some additional modules were defined for modeling relay logic, and an explanation and example of their use are included in this report.

Zimmerman, T.L.; Graves, N.L.; Payne, A.C. Jr.; Whitehead, D.W. [Sandia National Labs., Albuquerque, NM (United States)] [Sandia National Labs., Albuquerque, NM (United States)

1994-10-01T23:59:59.000Z

247

The San Andreas Fault System Paul Withers Wallace RE, The San Andreas Fault System, California, USGS Professional Paper 1515,  

E-Print Network [OSTI]

mainland Mexico. The San Andreas fault is commonly referred to as the boundary between the Pacific is correlated with the local geological setting. CO2 lubrication, #12;increased pore pressure, and decreased

Withers, Paul

248

Rupture Dynamics of Strike-Slip Faults with Stepovers: From Conceptually Simplified to Realistically Complex Fault Systems  

E-Print Network [OSTI]

This dissertation investigates the interaction of model II in-plane dynamic rupture with a geometrical discontinuity along the fault strike: stepover. One goal is to understand how large the stepover width must be to stop the dynamic rupture...

Liu, Zaifeng

2014-05-05T23:59:59.000Z

249

Abstract--A method for fault detection and isolation is proposed and applied to inverter faults in multi-phase drives. An  

E-Print Network [OSTI]

energy source, a five- leg inverter and a five-phase star-connected PMSM. It has to be noticed that all-magnet synchronous machine (PMSM) drive. The faults under consideration are: open-phase faults and open-switch faults

Boyer, Edmond

250

Delayed neutron detection with an integrated differential die-away and delayed neutron instrument  

SciTech Connect (OSTI)

The Next Generation Safeguards Initiative (NGSI) of the U.S. Department of Energy (DOE) has funded a multilab/university collaboration to quantify the plutonium (Pu) mass and detect the diversion of pins from spent nuclear fuel. The first two years of this NGSI effort was focused on quantifying the capability of a range of nondestructive assay (NDA) techniques with Monte Carlo (MCNPX) modeling and the second current phase involves measuring Spent Fuel. One of the techniques of interest in this paper involves measuring delayed neutrons. A delayed neutron instrument using 36 fission chambers and a 14 MeV neutron generator so called DT generator (Deuterium + Tritium) surrounding the fuel was previously studied as part of the NGSI effort. This paper will quantify the capability of a standalone delayed neutron instrument using 4 {sup 3}He gas filled tubes and a DT generator with significant spectrum tailoring, located far from the fuel. So that future research can assess how well a delayed neutron instrument will function as part of an integrated NDA system. A new design is going to be used to respond to the need of the techniques. This design has been modeled for a water media and is currently being optimized for borated water and air media as part of ongoing research. This new design was selected in order to minimize the fission of {sup 238}U, to use a more realistic neutron generator design in the model, to reduce cost and facilitate the integration of a delayed neutron (DN) with a differential die-away (DDA) instrument. Since this paper will focus on delayed neutron detection, the goal is to quantify the signal from {sup 235}U, {sup 239}Pu and {sup 241}Pu, which are the isotopes present in Spent Fuel that respond significantly to a neutron interrogation. This report will quantify the capability of this new delayed neutron design to measure the combined mass of {sup 235}U, {sup 239}Pu and {sup 241}Pu for 16 of the 64 assemblies of the NGSI Spent Fuel library in one of the three media, water.

Blanc, Pauline [Los Alamos National Laboratory; Tobin, Stephen J [Los Alamos National Laboratory; Lee, Taehoon [Los Alamos National Laboratory; Hu, Jianwei S [Los Alamos National Laboratory; Hendricks, John [Los Alamos National Laboratory; Croft, Stephen [Los Alamos National Laboratory

2010-01-01T23:59:59.000Z

251

E-Print Network 3.0 - average clear-sky broadband Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

which used data from the 15-yr... the oceans and showed that the clear-sky greenhouse effect was an ... Source: Allan, Richard P. - Department of Meteorology, University of...

252

Reactivity impact of delayed neutron spectra on MCNP calculations  

SciTech Connect (OSTI)

The new features in MCNP4C, the latest version of the MCNP Monte Carlo code, include the capability to sample from delayed as well as prompt fission emission spectra. Previous versions of MCNP all have sampled exclusively from prompt spectra. Delayed neutrons typically account for <1% of all neutrons emitted from fission, but the emission spectra for delayed neutrons are somewhat softer than those for prompt neutrons. Because of the softer spectrum, delayed neutrons are less likely to leak from the system, and they also are less likely to cause fission in isotopes that have an effective threshold for fission (e.g., {sup 238}U and {sup 240}Pu). Consequently, the inclusion of delayed neutron spectra can have a small but significant effect on reactivity calculations. This study performs MCNP4C calculations for a series of established benchmarks and quantifies the reactivity impact of the delayed neutron spectra.

Mosteller, R.D.; Werner, C.J.

2000-07-01T23:59:59.000Z

253

Experimental control of chaos by variable and distributed delay feedback  

E-Print Network [OSTI]

We report on a significant improvement of the classical time-delayed feedback control method for stabilization of unstable periodic orbits or steady states. In an electronic circuit experiment we were able to realize time-varying and distributed delays in the control force leading to successful control for large parameter sets including large time delays. The presented technique makes advanced use of the natural torsion of the orbits, which is also necessary for the original control method to work.

Thomas Jüngling; Aleksandar Gjurchinovski; Viktor Urumov

2012-02-02T23:59:59.000Z

254

arabidopsis delays leaf: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

mediated by delayed responses Katul, Gabriel 4 Chloroplast protein degradation during natural leaf senescence in Arabidopsis thaliana. Open Access Theses and Dissertations...

255

Delayed neutrons measurement at the MEGAPIE target  

E-Print Network [OSTI]

In the framework of the Neutronic and Nuclear Assessment Task Group of the MEGAPIE experiment we measured the delayed neutron (DN) flux at the top of the target. The measurement was proposed mainly for radioprotection purposes since the DN flux at the top of the target has been estimated to be of the same order of magnitude as the prompt neutron flux. Given the strong model-dependence of DN predictions, the measurement of DN contribution to the total neutron activity at the top of the target was thus desired. Moreover, this measurement is complementary to the DN experiments performed at PNPI (Gatchina) on solid lead and bismuth targets. The DN measurement at MEGAPIE was performed during the start-up phase of the target. In this paper we present a detailed description of the experimental setup and some preliminary results on decay spectra.

Stefano Panebianco; Pavel Bokov; Diane Dore; Xavier Ledoux; Alain Letourneau; Aurelien Prevost; Danas Ridikas

2007-05-25T23:59:59.000Z

256

Delayed neutrons measurement at the MEGAPIE target  

E-Print Network [OSTI]

In the framework of the Neutronic and Nuclear Assessment Task Group of the MEGAPIE experiment we measured the delayed neutron (DN) flux at the top of the target. The measurement was proposed mainly for radioprotection purposes since the DN flux at the top of the target has been estimated to be of the same order of magnitude as the prompt neutron flux. Given the strong model-dependence of DN predictions, the measurement of DN contribution to the total neutron activity at the top of the target was thus desired. Moreover, this measurement is complementary to the DN experiments performed at PNPI (Gatchina) on solid lead and bismuth targets. The DN measurement at MEGAPIE was performed during the start-up phase of the target. In this paper we present a detailed description of the experimental setup and some preliminary results on decay spectra.

Panebianco, Stefano; Dore, Diane; Ledoux, Xavier; Letourneau, Alain; Prevost, Aurelien; Ridikas, Danas

2007-01-01T23:59:59.000Z

257

Delayed neutron alignment in sup 117 I  

SciTech Connect (OSTI)

The rotational alignment of {ital h}{sub 11/2} neutrons is considerably delayed ({Delta}{h bar}{omega}{similar to}0.11 MeV) in the {pi}{ital h}{sub 11/2}(550)1/2{sup {minus}} intruder band in {sup 117}I when compared to bands built on normal-parity states. Comparison with cranked shell-model calculations suggests that this effect may indicate a larger quadrupole deformation for the intruder orbital. A strong neutron-proton interaction between the aligning {ital h}{sub 11/2} neutrons and the {ital h}{sub 11/2} proton intruder may also play a role. In addition, noncollective oblate states at {ital I}{sup {pi}}=39/2{sup {minus}},43/2{sup {minus}}, and 45/2{sup {minus}} compete energetically with rotational states of the intruder band which may also perturb the neutron alignment.

Paul, E.S.; Waring, M.P.; Clark, R.M.; Forbes, S.A.; Fossan, D.B.; Hughes, J.R.; LaFosse, D.R.; Liang, Y.; Ma, R.; Vaska, P.; Wadsworth, R. (Oliver Lodge Laboratory, University of Liverpool, P.O. Box 147, Liverpool L69 3BX (United Kingdom) Department of Physics, State University of New York at Stony Brook, Stony Brook, New York 11794 (United States) Department of Physics, University of York, Heslington, York YO1 5DD (United Kingdom) Medical Department, Brookhaven National Laboratory, Upton, New York 11973 (United States))

1992-06-01T23:59:59.000Z

258

Optically controlled delays for broadband pulses  

E-Print Network [OSTI]

susceptibility is given by #4;#1;#1;#5;p#2; #12; ? #6;#7;#8;p #5; #5;2 . #1;7#2; Therefore, at a position z, the delayed probe pulse is given by p#1;t,z#2; = p0 exp ? #1;t ? z/vg#2;22T2 , #1;8#2; where the group velocity of the optical pulse is vg#12... Security Agency, and the Army Research Office. #3;1#4; T. Kamiya, F. Saito, O. Wada, and H. Yajima, Femtosecond Technology #1;Springer, Berlin, 1999#2;. #3;2#4; S. E. Harris and L. V. Hau, Phys. Rev. Lett. 82, 4611 #1;1999#2;; P. C. Ku, C. J. Chang...

Sun, Q. Q.; Rostovtsev, Y. V.; Dowling, J. P.; Scully, Marlan O.; Zubairy, M. Suhail

2005-01-01T23:59:59.000Z

259

Erasure of Time Delay Signatures in the Output of an Optoelectronic Feedback Laser with Modulated Delays and Chaos Synchronization  

E-Print Network [OSTI]

By studying the autocorrelation function of the optoelectronic feedback semiconductor laser output we establish that the signatures of time delays can be erased in systems incorporating modulated feedback time delays. This property is of importance for the suitability of such laser systems for secure chaos-based communication systems. We also make the first report on chaos synchronization in both unidirectionally and bidirectionally coupled multiple time delay chaotic semiconductor lasers with modulated optoelectronic feedbacks.

E. M. Shahverdiev; K. A. Shore

2009-06-17T23:59:59.000Z

260

Accident Fault Trees for Defense Waste Processing Facility  

SciTech Connect (OSTI)

The purpose of this report is to document fault tree analyses which have been completed for the Defense Waste Processing Facility (DWPF) safety analysis. Logic models for equipment failures and human error combinations that could lead to flammable gas explosions in various process tanks, or failure of critical support systems were developed for internal initiating events and for earthquakes. These fault trees provide frequency estimates for support systems failures and accidents that could lead to radioactive and hazardous chemical releases both on-site and off-site. Top event frequency results from these fault trees will be used in further APET analyses to calculate accident risk associated with DWPF facility operations. This report lists and explains important underlying assumptions, provides references for failure data sources, and briefly describes the fault tree method used. Specific commitments from DWPF to provide new procedural/administrative controls or system design changes are listed in the ''Facility Commitments'' section. The purpose of the ''Assumptions'' section is to clarify the basis for fault tree modeling, and is not necessarily a list of items required to be protected by Technical Safety Requirements (TSRs).

Sarrack, A.G.

1999-06-22T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Dynamical behaviours in time-delay systems with delayed feedback and digitized coupling  

E-Print Network [OSTI]

We consider a network of delay dynamical systems connected in a ring via unidirectional positive feedback with constant delay in coupling. For the specific case of Mackey-Glass systems on the ring topology, we capture the phenomena of amplitude death, isochronous synchronization and phase-flip bifurcation as the relevant parameters are tuned. Using linear stability analysis and master stability function approach, we predict the region of amplitude death and synchronized states respectively in the parameter space and study the nature of transitions between the different states. For a large number of systems in the same dynamical configuration, we observe splay states, mixed splay states and phase locked clusters. We extend the study to the case of digitized coupling and observe that these emergent states still persist. However, the sampling and quantization reduce the regions of amplitude death and induce phase-flip bifurcation.

Chiranjit Mitra; G. Ambika; Soumitro Banerjee

2014-11-05T23:59:59.000Z

262

Robust Airline Schedule Planning: Minimizing Propagated Delay in ...  

E-Print Network [OSTI]

highly brittle, performing poorly in practice as delays propagate rapidly throughout the network. The. Bureau of .... In contrast to airline recovery, where the objective is to achieve the best ..... weather conditions, air traffic flow management, passenger delays, equipment failure, and so on. ...... Airport Handling Manual. 2010.

2011-10-06T23:59:59.000Z

263

MCNP6 enhancements of delayed-particle production  

SciTech Connect (OSTI)

Over the last decade, there has been an increased interest in the production of delayed-particle signatures from neutron and photon interactions with matter. To address this interest, various radiation transport codes have developed a wide range of delayed-particle physics packages. With the recent merger of the Monte Carlo transport codes MCNP5 and MCNPX, MCNP6 inherited the comprehensive model-based delayed-particle production capabilities developed in MCNPX over the last few years. An integral part of this capability consists of the depletion code CINDER90 which was incorporated into MCNPX in 2004. During this last year, significant improvements have been made to the MCNP6 physics and algorithms associated with delayed-particle production, including the development of a delayed-beta capability, an algorithm enhancement for the delayed-neutron treatment, and a database enhancement for delayed-gamma emission. The delayed-beta feature represents an important component in modeling background signals produced by active interrogation sources. Combined, these improvements provide MCNP6 with a flexible state-of-the-art physics package for generating high-fidelity signatures from fission and activation. This paper provides details of these enhancements and presents results for a variety of fission and activation examples. (authors)

McKinney, G. W. [Los Alamos National Laboratory, MS C921, P.O. Box 1663, Los Alamos, NM 87545 (United States)

2012-07-01T23:59:59.000Z

264

M/M/1 Queueing System with Delayed Controlled Vacation  

E-Print Network [OSTI]

M/M/1 Queueing System with Delayed Controlled Vacation Yonglu Deng , Zhongshan University W. John systems using a time division multiple access (TDMA) scheme (Frey and Takahashi, [7]). Researchers have that of a server's cold switch-on. The case of delayed vacation has also very recently been studied by Frey

Zhao, Yiqiang Q.

265

Utility Maximization for Delay Constrained QoS in Wireless  

E-Print Network [OSTI]

Utility Maximization for Delay Constrained QoS in Wireless I-Hong Hou CSL and Department of CS of utility maxi- mization for clients with delay based QoS requirements in wireless networks. We adopt that the utility of a client is a function of the timely throughput it obtains. We treat the timely throughput

266

MISO Broadcast Channel with Delayed and Evolving CSIT  

E-Print Network [OSTI]

MISO Broadcast Channel with Delayed and Evolving CSIT Jinyuan Chen and Petros Elia Mobile--The work considers the two-user MISO broadcast channel with a gradual and delayed accumulation of channel-input single-output broadcast channel (MISO BC) with an M-transmit antenna (M 2) transmitter communicating

Gesbert, David

267

Convex Delay Models for Transistor Sizing Mahesh Ketkar  

E-Print Network [OSTI]

for developing accurate con- vex delay models to be used for transistor sizing. A new rich class of convex]: minimize Area or Power subject to Delay Tspec: (1) There have been many significant attempts to solve. in the development of closed form models for inverters and then mapping other gates to an equivalent inverter [5, 6

Sapatnekar, Sachin

268

Regenerative memory in time-delayed neuromorphic photonic systems  

E-Print Network [OSTI]

We investigate a regenerative memory based upon a time-delayed neuromorphic photonic oscillator and discuss the link with temporal localized structures. Our experimental implementation is based upon a optoelectronic system composed of a nanoscale nonlinear resonant tunneling diode coupled to a laser that we link to the paradigm of neuronal activity, the FitzHugh-Nagumo model with delayed feedback.

Romeira, B; Figueiredo, José M L; Barland, S; Javaloyes, J

2015-01-01T23:59:59.000Z

269

Delays associated with elementary processes in nuclear reaction simulations  

SciTech Connect (OSTI)

Scatterings, particularly those involving resonances, and other elementary processes do not happen instantaneously. In the context of semiclassical nuclear reaction simulations, we consider delays associated with an interaction for incident quantum wave packets. As a consequence, we express delays associated with elementary processes in terms of elements of the scattering matrix and phase shifts for elastic scattering. We show that, within the second order in density, the simulation must account for delays in scattering consistently with the mean field in order to properly model thermodynamic properties such as pressure and free-energy density. Delays associated with nucleon-nucleon and pion-nucleon scattering in free space are analyzed with their nontrivial energy dependence. Finally, an example of {ital s}-channel scattering of massless partons is studied, and scattering schemes in nuclear reaction simulations are investigated in the context of scattering delays. {copyright} {ital 1996 The American Physical Society.}

Danielewicz, P.; Pratt, S. [National Superconducting Cyclotron Laboratory and Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824 (United States)] [National Superconducting Cyclotron Laboratory and Department of Physics and Astronomy, Michigan State University, East Lansing, Michigan 48824 (United States); [Grand Accelerateur National dIons Lourds (GANIL), BP 5027, F-14021 Caen Cedex (France)

1996-01-01T23:59:59.000Z

270

E-Print Network 3.0 - active fault system Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: -8141(95)00105-0 Experimental modeling of extensional fault systems by use of plaster HAAKON FOSSEN Statoil, N-5020 Bergen... -scale structures in relation to larger fault...

271

Initiation propagation and termination of elastodynamic ruptures associated with segmentation of faults and shaking  

E-Print Network [OSTI]

Initiation propagation and termination of elastodynamic ruptures associated with segmentation the initiation, propagation, and termination of ruptures and their relationship to fault geometry and shaking of terminations near fault ends; and persistent propagation directivity effects. Taking advantage of long

Shaw, Bruce E.

272

E-Print Network 3.0 - active fault isolation Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and those exhibited by much smaller (L 0.15-2 km) more isolated faults... Post-yield fracture mechanics models for the growth of an isolated fault predict a linear...

273

E-Print Network 3.0 - analog fault simulation Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Sciences 65 Channel flow and the development of parallel-dipping normal faults Thorsten J. Nagel1 Summary: -dipping normal faults we carried out a series of numerical experiments...

274

Characterization of the structure of faults in the Eocene Carrizo Formation near Gause, Milam County, Texas  

E-Print Network [OSTI]

-scale graben accommodating NW-SE extension. The Carrizo Fm. consists primarily of friable to weakly lithified quartz sandstones with several horizons with interbedded siltstones and shales. Five faults and fault zones occur in the quarry with displacements...

Yilmaz, Ramazan

2012-06-07T23:59:59.000Z

275

The dynamics of oceanic transform faults : constraints from geophysical, geochemical, and geodynamical modeling  

E-Print Network [OSTI]

Segmentation and crustal accretion at oceanic transform fault systems are investigated through a combination of geophysical data analysis and geodynamical and geochemical modeling. Chapter 1 examines the effect of fault ...

Gregg, Patricia Michelle Marie

2008-01-01T23:59:59.000Z

276

Fault Current Issues for Market Driven Power Systems with Distributed Generation  

E-Print Network [OSTI]

1 Fault Current Issues for Market Driven Power Systems with Distributed Generation Natthaphob of installing distributed generation (DG) to electric power systems. The proliferation of new generators creates Terms--Distributed / dispersed generation, power distri- bution, power system protection, fault

277

E-Print Network 3.0 - automatic fault tree Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Search Sample search results for: automatic fault tree Page: << < 1 2 3 4 5 > >> 1 Computer diagnosis systems grounded on hand-crafted fault trees are wide-spread in industrial...

278

Slip on ridge transform faults : insights from earthquakes and laboratory experiments  

E-Print Network [OSTI]

The relatively simple tectonic environment of mid-ocean ridge transform fault (RTF) seismicity provides a unique opportunity for investigation of earthquake and faulting processes. We develop a scaling model that is complete ...

Boettcher, Margaret S

2005-01-01T23:59:59.000Z

279

A methodology for experimentally verifying simulation models for distribution transformer internal faults  

E-Print Network [OSTI]

Internal winding faults comprise 70-80% of modem transformer breakdown. In this era of deregulation, this phenomenon is likely to increase since loading transformers to their optimum capacity is becoming normal practice. These internal faults result...

Palmer-Buckle, Peter

1999-01-01T23:59:59.000Z

280

Locating an active fault zone in Coso geothermal field by analyzing...  

Open Energy Info (EERE)

production and injection drilling, since an active fault zone often acts as a fracture-extensive low-velocity wave guide to seismic waves. We have located an active fault...

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Power system fault analysis based on intelligent techniques and intelligent electronic device data  

E-Print Network [OSTI]

This dissertation has focused on automated power system fault analysis. New contributions to fault section estimation, protection system performance evaluation and power system/protection system interactive simulation have been achieved. Intelligent...

Luo, Xu

2007-09-17T23:59:59.000Z

282

The effect of fault relayand clay smearing on groundwater flow patterns in the Lower Rhine  

E-Print Network [OSTI]

in the unconsolidated sediments of the Lower Rhine Embayment. Hydraulic head maps show that many individual faults form unconsolidated sediments at shal- low depth is likely to be di¡erent from that of faults at depths where rocks

Bense, Victor

283

Development of a methodology to discriminate incipient insulator faults from distribution system load  

E-Print Network [OSTI]

of incipient insulator faults 4. Determining characteristics most likely to discriminate incipient insulator faults from distribution system load current From this work, the aggregate of the non-harmonic components and the high frequency energy of the leakage...

Richards, Christopher Scott

2000-01-01T23:59:59.000Z

284

Analysis of electrical signatures in synchronous generators characterized by bearing faults  

E-Print Network [OSTI]

Synchronous generators play a vital role in power systems. One of the major mechanical faults in synchronous generators is related to bearings. The popular vibration analysis method has been utilized to detect bearing faults for years. However...

Choi, Jae-Won

2009-05-15T23:59:59.000Z

285

Paleoearthquakes of the past 30,000 years along the North Tehran Fault (Iran)  

E-Print Network [OSTI]

Paleoearthquakes of the past 30,000 years along the North Tehran Fault (Iran) J.-F. Ritz,1 H. Ghorashi, and A. Saidi (2012), Paleoearthquakes of the past 30,000 years along the North Tehran Fault (Iran

286

Thermo-and hydro-mechanical processes along faults during rapid slip  

E-Print Network [OSTI]

Thermo- and hydro-mechanical processes along faults during rapid slip James R. Rice & Eric M micro-contacts, and (2) Thermal pressurization of fault-zone pore fluid. Both have characteristics which

Dunham, Eric M.

287

Tarmat behavior calculated for reservoir with sealing fault  

SciTech Connect (OSTI)

The Minagish Oolite oil reservoir in Kuwait is one of many Middle East reservoirs characterized by the presence of a tarmat (heavy to tar-like crude) at the oil-water contact. Since a waterflood project is planned for the Minagish Oolite, which contains a radial pattern of faults, a study was made to consider tarmat behavior upon water injection below it when the injection well is located near a sealing fault. The study resulted in a technique to predict the time of tarmat breakdown, response time at the nearest observation well, and differential pressure at the tarmat anywhere in the reservoir.

Osman, M.E.S.

1986-08-01T23:59:59.000Z

288

Fault-Tolerant Quantum Computation via Exchange interactions  

E-Print Network [OSTI]

Quantum computation can be performed by encoding logical qubits into the states of two or more physical qubits, and controlling a single effective exchange interaction and possibly a global magnetic field. This "encoded universality" paradigm offers potential simplifications in quantum computer design since it does away with the need to perform single-qubit rotations. Here we show that encoded universality schemes can be combined with quantum error correction. In particular, we show explicitly how to perform fault-tolerant leakage correction, thus overcoming the main obstacle to fault-tolerant encoded universality.

M. Mohseni; D. A. Lidar

2004-06-25T23:59:59.000Z

289

Proposal for ENDF formats that describe emission of post-fission beta-delayed photons  

SciTech Connect (OSTI)

Fission of heavy nuclides is accompanied by the birth of neutron rich fragment nuclei born in highly excited states. Following emission of prompt neutrons and {gamma}-rays, these fragments are typically left with atomic numbers that are 3-4 units smaller than stable nuclei with the same mass number. As these nuclides undergo {beta} decay to reach stability, a large number of {gamma}-rays are emitted. Figure 1 illustrates some of the processes leading to emission of {beta} delayed photons. A variety of applications (most notably those concerned with the detection and identification of clandestine fissile material) would benefit from a clear description of the spectral and temporal evolution of these {gamma}-rays. This proposal describes formats for representing emission of delayed photons and is based on the analysis presented in. At the present time, no single evaluated data set exists that directly provides for the temporal evolution of {gamma} rays from the decay of the fission products. However, evaluated data sets containing all of the physical parameters required for such calculations have been prepared. These include estimates of the independent and cumulative fission yields of all fission products, branching ratios in the decay of ground and isomeric states, lifetimes of these states, and the spectra of {gamma} rays emitted in their decay. Sizeable uncertainties and possibly significant errors are likely present concerning the shortest-lived fission products. However, the high-energy {gamma}-ray spectra generated from some of these data sets have been shown to be in reasonable agreement with initial experiments designed specifically to test them under conditions likely to be of interest to interrogation of sea-going cargo containers. For clarity we emphasize that the relationship between delayed neutron emission and delayed photon emission is tenuous. Only a small fraction of fission fragments - typically those characterized by large decay Q values - undergo {beta}{sup -}n emission. However, essentially all fission fragment decays result in the emission of a few photons. Also, it would be impractical to accurately specify and measure energies of delayed neutrons. By contrast, most fission fragments have decay spectra known to sub-keV accuracy that are readily resolved with inexpensive field HpGe detectors.

Brown, D; Pruet, J; Hedstrom, G; Hall, J; Descalle, M

2004-09-15T23:59:59.000Z

290

IEEE TRANSACTIONS ON POWER ELECTRONICS 1 A Fault-Tolerant Switching Scheme for an Isolated  

E-Print Network [OSTI]

a model- reference adaptive system-based fault diagnosis algorithm for a VSI used as a PMSM drive system

Mazumder, Sudip K.

291

Status of six-group delayed neutron data and relationships between delayed neutron parameters from the macroscopic and microscopic approaches  

SciTech Connect (OSTI)

Work performed in part for an American Nuclear Society Standards Committee Subgroup (ANS 19.9) to assess the status of delayed neutron data is summarized. Recent measurements of delayed neutron emission conducted at Texas A and M University are also described. During the last 10 yr, there have been advances in nuclear data libraries (e.g., improved fission product yields) that make it possible to quantitatively predict delayed neutron emission from basic data. The six-group delayed neutron data available in the literature from both macroscopic level experiments and microscopic level calculations for several actinide isotopes are compared. Results are also presented from recent experimental measurements of delayed neutron emission and delineates some of the relationships between these measurements and microscopic level predictions. For example, from the experimental measurements, Keepin`s delayed neutron group 1 is shown to correspond mainly to a single isotope. {sup 87}Br, as expected from microscopic level theory, and Keepin`s group 2 is shown to correspond to primarily two separate isotopes. {sup 137}I and {sup 88}Br. In the future, it may be useful to use properties of specific isotopes to replace Keepin`s delayed neutron groups 1, 2, 3, and 4 for prescribing delayed neutron data for actinides.

Parish, T.A.; Charlton, W.S. [Texas A and M Univ., College Station, TX (United States). Nuclear Engineering Dept.; Shinohara, N.; Andoh, M. [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan); Brady, M.C. [Duke Engineering and Services, Inc., Charlotte, NC (United States); Raman, S. [Oak Ridge National Lab., TN (United States)

1999-02-01T23:59:59.000Z

292

Syneresis and delayed detachment in agar plates  

E-Print Network [OSTI]

Biogels made of crosslinked polymers such as proteins or polysaccharides behave as porous soft solids and store large amount of solvent. These gels undergo spontaneous aging, called syneresis that consists in the shrinkage of the gel matrix and the progressive expulsion of the solvent, which eventually leads to the gel detachment from its container. Here we report on the syneresis phenomena in agar plates that consist in Petri dishes filled with a gel mainly composed of agar. Direct observations and speckle pattern correlation analyses allow us to rationalize the delayed detachment of the gel from the sidewall of the Petri dish. The detachment time $t^*$ is mainly controlled by the gel minimum thickness $e_{min}$ along the periphery of the plate: $t^*$ increases as a robust function of $e_{min}$ that neither depends on the age of the gel nor on any previous mass loss. Time-resolved correlation spectroscopy reveals that the speckle decorrelation rate increases a few hours before $t^*$ and that the gel detachment can be anticipated. This work provides quantitative observables to predict the shelf life of agar plates and highlights the key role of the competition between the syneresis and the gel adhesion to the wall in the detachment process.

Thibaut Divoux; Bosi Mao; Patrick Snabre

2014-10-30T23:59:59.000Z

293

State of the art analysis of online fault location on AC cables in underground transmission systems  

E-Print Network [OSTI]

on transmission level fault location methods have been focused on overhead lines. Because of the very different- termine the fault location. Because only one end meas- urements are used, the algorithm is derived usingState of the art analysis of online fault location on AC cables in underground transmission systems

Bak, Claus Leth

294

RELIABILITY ANALYSIS IN A FAULT TOLERANT CONTROL STRATEGY DEDICATED TO ACTIVE POWER FILTER  

E-Print Network [OSTI]

RELIABILITY ANALYSIS IN A FAULT TOLERANT CONTROL STRATEGY DEDICATED TO ACTIVE POWER FILTER P. WEBER on reliability analysis dedicated to an active power filter. Once a fault has been detected and isolated, all reliability indicate the optimal structure. Keywords: Fault Tolerant Control, System Reliability, Active power

Paris-Sud XI, Université de

295

Dynamic rupture through a branched fault2 configuration at Yucca Mountain and resulting3  

E-Print Network [OSTI]

Dynamic rupture through a branched fault2 configuration at Yucca Mountain and resulting3 ground analyses. This is motivated by the normal faults in the vicinity10 of Yucca Mountain, NV, a potential site fault12 located approximately 1 km west of the crest of Yucca Mountain, is the13 most active

Dmowska, Renata

296

Bearing Fault Detection in DFIG-Based Wind Turbines Using the First Intrinsic Mode Function  

E-Print Network [OSTI]

Bearing Fault Detection in DFIG-Based Wind Turbines Using the First Intrinsic Mode Function Y for bearing fault detection in DFIG-based wind turbines. The proposed method uses the first Intrinsic Mode Terms--Wind turbine, Doubly Fed Induction Generator (DFIG), fault detection, bearings, signal processing

Boyer, Edmond

297

IPR: In-Place Reconfiguration for FPGA Fault Tolerance and Rupak Majumdar2  

E-Print Network [OSTI]

IPR: In-Place Reconfiguration for FPGA Fault Tolerance Zhe Feng1 , Yu Hu1 , Lei He1 and Rupak Angeles ABSTRACT We describe In-Place Reconfiguration (IPR) for LUT-based FPGAs, an algorithm the propagation of faults seen at a pair of comple- mentary inputs. Based on IPR, we develop a fault

He, Lei

298

Performance of Graceful Degradation for Cache Faults Hyunjin Lee Sangyeun Cho Bruce R. Childers  

E-Print Network [OSTI]

Performance of Graceful Degradation for Cache Faults Hyunjin Lee Sangyeun Cho Bruce R. Childers to thermal hot spots) and may man- ifest themselves as operational faults at the micro- Bruce Childers that is dependent on the fault and the frequency of access to an address that would normally be held in the disabled

Cho, Sangyeun

299

What about vulnerability to a fault attack of the Miller algorithm during an  

E-Print Network [OSTI]

What about vulnerability to a fault attack of the Miller algorithm during an Identity Based is to analyse the weakness of the Miller algorithm when it undergoes a fault attack. We prove that the Miller algorithm is vulnerable to a fault attack which is valid in all coordinate systems, through the resolution

Paris-Sud XI, Université de

300

What About Vulnerability to a Fault Attack of the Miller's Algorithm During an  

E-Print Network [OSTI]

What About Vulnerability to a Fault Attack of the Miller's Algorithm During an Identity Based of this article is to analyse the weakness of the Miller's algorithm when it undergoes a fault attack. We prove that the Miller's algorithm is vulnerable to a fault attack which is valid in all coordinate systems, through

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Shallow soil CO2 flow along the San Andreas and Calaveras Faults, California  

E-Print Network [OSTI]

Shallow soil CO2 flow along the San Andreas and Calaveras Faults, California J. L. Lewicki,1,2 W. C soil CO2 survey along the San Andreas fault (SAF) in Parkfield, and the Calaveras fault (CF) in Hollister, California, in the context of spatial and temporal variability, origin, and transport of CO2

Hilley, George

302

A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS  

E-Print Network [OSTI]

1 A CONTROLLER FOR HVAC SYSTEMS WITH FAULT DETECTION CAPABILITIES BASED ON SIMULATION MODELS T. I describes a control scheme with fault detection capabilities suitable for application to HVAC systems as a reference of correct operation. Faults that occur in the HVAC system under control cause the PI

303

Yield Modeling and Analysis of a Clockless Asynchronous Wave Pipeline with Pulse Faults  

E-Print Network [OSTI]

Yield Modeling and Analysis of a Clockless Asynchronous Wave Pipeline with Pulse Faults T. Feng fault model and its modeling and analysis methods in a clockless asynchronous wave pipeline fault rate model for establishing a sound theoretical foundation for clockless wave pipeline design

Ayers, Joseph

304

Acoustic Emission, Cylinder Pressure and Vibration: A Multisensor Approach to Robust Fault Diagnosis \\Lambda  

E-Print Network [OSTI]

of a diesel engine and 4 fault conditions, Artificial Neural Nets based on data from any one of these three and challenging task for Artificial Neural Nets (ANNs) is the on­line fault dia­ gnosis of a diesel engine. One way of meeting this challenge is to physically induce faults in a diesel engine, to collect data

Sharkey, Amanda

305

Mineralogical characterization of protolith and fault rocks from the SAFOD Main Hole  

E-Print Network [OSTI]

Mineralogical characterization of protolith and fault rocks from the SAFOD Main Hole John G. Solum influence is not yet fully known. Faults containing these mineralogical phases are prime candidates), Mineralogical characterization of protolith and fault rocks from the SAFOD Main Hole, Geophys. Res. Lett., 33, L

306

A simple packet retransmission strategy for throughput and delay enhancement on power line communication channels  

SciTech Connect (OSTI)

A new, simple, and effective communication protocol is developed and evaluated for use on power line distribution networks. The protocol involves retransmission of unacknowledged packets, which are sent in either single or multiple (N) copies in accordance with estimates of communication link quality. Multiple packet copies can be code combined at the receiver, using majority voting on each bit position, to reduce packet error rates. Adaptive link quality estimates are based on the receipt or absence of positive acknowledgements. Information throughput efficiency is calculated and N optimized in terms of system variables. Performance benefits of code combining are clearly demonstrated. The algorithm was implemented and tested using a five-station intrabuilding power line communications network operating at 1.2, 2.4, 4.8 and 9.6 kbit/s data rate. Substantial throughput and delay improvement occurred on poor quality links, without degrading performance on good links.

Onunga, J.O. (Kenya Posts and Telecommunications Corp., Nairobi (Kenya)); Donaldson, R.W. (Univ. of British Columbia, Vancouver (Canada). Dept. of Electrical Engineering)

1993-07-01T23:59:59.000Z

307

Institute for Health Research and Policy Distinguished Lecture Pfizer Visiting Professorship of Clear Health Communication  

E-Print Network [OSTI]

Institute for Health Research and Policy Distinguished Lecture Pfizer Visiting Professorship of Clear Health Communication April 8, 2009 Matthew W. Kreuter, PhD, MPH Washington University in St. Louis St. Louis, MO Communication-based strategies to eliminate health disparities in diverse populations

Illinois at Chicago, University of

308

Personal Data Sheet Please print clearly and check all that apply  

E-Print Network [OSTI]

EmplID: ePAF #: 14May2012 Personal Data Sheet Please print clearly and check all that apply New No Signature: Date: #12;Personal Data Sheet Ethnic Groups White: A person having origins in any of the original Hire: Personal Email Address:__________________________________________ Record Update: Please use

Wu, Shin-Tson

309

Cloudy Sky Version of Bird's Broadband Hourly Clear Sky Model (Presentation)  

SciTech Connect (OSTI)

Presentation on Bird's Broadband Hourly Clear Sky Model given by NREL's Daryl Myers at SOLAR 2006. The objective of this report is to produce ''all sky'' modeled hourly solar radiation. This is based on observed cloud cover data using a SIMPLE model.

Myers, D.

2006-08-01T23:59:59.000Z

310

WHAT DO STIA PARTICIPANTS SAY? STIA helped me to develop a clear conception of my course.  

E-Print Network [OSTI]

WHAT DO STIA PARTICIPANTS SAY? STIA helped me to develop a clear conception of my course. It made, for each class and for my teaching in general (teaching philosophy). STIA gave me a variety of teaching techniques to use in my class to get students involved. STIA helped me tremendously. I highly recommend it! I

Akhmedov, Azer

311

Change in the hydraulic properties of a Brazilian clay Ferralsol on clearing for pasture  

E-Print Network [OSTI]

Change in the hydraulic properties of a Brazilian clay Ferralsol on clearing for pasture L. C 80 to 300 m in size. The aim of this study was to analyze how the hydraulic properties of a clay retention properties were determined by using pressure cell equipment. We determined the saturated hydraulic

Boyer, Edmond

312

A Multiscale Investigation of Ground Water Flow at Clear Lake, Iowa  

E-Print Network [OSTI]

targets. The model produced ground water inflow and outflow rates of 14,300 and 9200 m3/d, respectively­related problems in the lake and its water- shed, their likely causes, and potential remedial measuresA Multiscale Investigation of Ground Water Flow at Clear Lake, Iowa by William W. Simpkins Abstract

Simpkins, William W.

313

The Total Number of Giant Planets in Debris Disks with Central Clearings  

E-Print Network [OSTI]

Infrared spectra from the Spitzer Space Telescope (SSC) of many debris disks are well fit with a single black body temperature which suggest clearings within the disk. We assume that inside the clearing orbital instability due to planets removes dust generating planetesimal belts and dust generated by the outer disk that is scattered or drifts into the clearing. From numerical integrations we estimate a minimum planet spacing required for orbital instability (and so planetesimal and dust removal) as a function of system age and planet mass. We estimate that a 10^8 year old debris disk with a dust disk edge at a radius of 50 AU hosted by an A star must contain approximately 5 Neptune mass planets between the clearing radius and the iceline in order to remove all primordial objects within it. We infer that known debris disk systems contain at least a fifth of a Jupiter mass in massive planets. The number of planets and spacing required is insensitive to the assumed planet mass. However an order of magnitude higher total mass in planets could reside in these systems if the planets are more massive.

Peter Faber; Alice C. Quillen

2007-06-12T23:59:59.000Z

314

Horizon brightness revisited: measurements and a model of clear-sky radiances  

E-Print Network [OSTI]

from solar energy engineering2 ,3 to atmospheric optics4'5 have repeatedly measured and modeled. Second, before the advent of narrow field-of-view (FOV) radiometers8 and photographic analysis tech explanation of the phenomenon. High-Resolution Measurements of Clear-Sky Radiances We beginby electronically

Lee Jr., Raymond L.

315

Clearing, Sanitization, and Destruction of Information System Storage Media, Memory Devices, and Related Hardware Manual  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The manual establishes the DOE requirements and responsibilities for clearing, sanitizing, and destroying DOE information system storage media, memory devices, and related hardware to ensure that no unauthorized information can be retrieved. Canceled by DOE N 205.17. Cancels DOE N 205.12

2005-06-21T23:59:59.000Z

316

Forest Clearing in the Ecuadorian Amazon: A Study of Patterns Over Space and Time  

E-Print Network [OSTI]

on a farm (finca) leads to more deforestation; (2) rates of forest clearing surrounding four primary to deforestation; and deforestation rates W. Pan (&) Department of International Health, The Johns Hopkins to increase agricultural intensification. Keywords Deforestation Á Ecuador Á Land use Á Population policy Á

Lopez-Carr, David

317

Biodiesel Clears the Air in Underground Mines, Clean Cities, Fact Sheet, June 2009  

SciTech Connect (OSTI)

Mining companies are using biodiesel in their equipment to help clear the air of diesel particulate matter (DPM). This action improves air quality and protects miners' lungs. Though using biodiesel has some challenges in cold weather, tax incentives, and health benefits make it a viable option.

Not Available

2009-06-01T23:59:59.000Z

318

CBER-DETR Nevada Coincident and Leading Employment No Clear Signal  

E-Print Network [OSTI]

by the Bureau of Labor Statistics. The Nevada Coincident Employment Index includes four employment measuresCBER-DETR Nevada Coincident and Leading Employment Indexes1 No Clear Signal by Bob Potts Center for Business and Economic Research University of Nevada, Las Vegas The Nevada Coincident Employment Index

Ahmad, Sajjad

319

IL/EBP EducatIon The team space clearly documents behaviors  

E-Print Network [OSTI]

IL/EBP EducatIon The team space clearly documents behaviors in the realm of practice-based learning clinical competency. team 2.0: a collaborative online method for knowledge management in academic medicine Authors: Lauren A. Maggio, MS (LIS), MA, AHIP; Keith A. Posley, MD, MS LANE KNOWLEDGE MANAGEMENT CENTER

Kay, Mark A.

320

Evaluation and application of delayed neutron precursor data  

SciTech Connect (OSTI)

Up to 1300 nuclides are yielded in fission. Of these, 271 have been identified as precursors for delayed neutron emission. An extensive reference library of delayed neutron data has been compiled which contains fission yields and branchings, delay neutron emission probabilities and spectra for each of these 271 precursor nuclides. The emphasis of the present work has been in improving the spectral data. Experimental spectra from laboratories in the United States, Germany, and Sweden have been incorporated in this evaluation. The experimental spectra have been augmented with model calculations such that the spectra included in the final library extend over the full theoretical energy range for delayed neutron emission. Models were also used to predict spectra for nuclides with no measured data. The data compiled in the precursor library have been used to calculate the aggregate behavior of delayed neutrons for the 43 fissioning systems having evaluated fission yields. Delayed neutron activities predicted using the explicit precursor data have also been approximated by three, six, nine and twelve time-groups using least squares techniques. The fitted six group data, being the more conventional representation, were also used to predict a consistent set of six-group spectra. Comparisons with the University of Lowell's recently published measurements of /sup 235/U delay interval spectra were also made. Beta-effective calculations for a simple Godiva system were performed and were compared to the experimental value.

Brady, M.C.

1989-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Development of a statistically based access delay timeline methodology.  

SciTech Connect (OSTI)

The charter for adversarial delay is to hinder access to critical resources through the use of physical systems increasing an adversary's task time. The traditional method for characterizing access delay has been a simple model focused on accumulating times required to complete each task with little regard to uncertainty, complexity, or decreased efficiency associated with multiple sequential tasks or stress. The delay associated with any given barrier or path is further discounted to worst-case, and often unrealistic, times based on a high-level adversary, resulting in a highly conservative calculation of total delay. This leads to delay systems that require significant funding and personnel resources in order to defend against the assumed threat, which for many sites and applications becomes cost prohibitive. A new methodology has been developed that considers the uncertainties inherent in the problem to develop a realistic timeline distribution for a given adversary path. This new methodology incorporates advanced Bayesian statistical theory and methodologies, taking into account small sample size, expert judgment, human factors and threat uncertainty. The result is an algorithm that can calculate a probability distribution function of delay times directly related to system risk. Through further analysis, the access delay analyst or end user can use the results in making informed decisions while weighing benefits against risks, ultimately resulting in greater system effectiveness with lower cost.

Rivera, W. Gary; Robinson, David Gerald; Wyss, Gregory Dane; Hendrickson, Stacey M. Langfitt

2013-02-01T23:59:59.000Z

322

Delayed feedback control of fractional-order chaotic systems  

E-Print Network [OSTI]

We study the possibility to stabilize unstable steady states and unstable periodic orbits in chaotic fractional-order dynamical systems by the time-delayed feedback method. By performing a linear stability analysis, we establish the parameter ranges for successful stabilization of unstable equilibria in the plane parametrizad by the feedback gain and the time delay. An insight into the control mechanism is gained by analyzing the characteristic equation of the controlled system, showing that the control scheme fails to control unstable equilibria having an odd number of positive real eigenvalues. We demonstrate that the method can also stabilize unstable periodic orbits for a suitable choice of the feedback gain, providing that the time delay is chosen to coincide with the period of the target orbit. In addition, it is shown numerically that delayed feedback control with a sinusoidally modulated time delay significantly enlarges the stability region of the steady states in comparison to the classical time-delayed feedback scheme with a constant delay.

Aleksandar Gjurchinovski; Trifce Sandev; Viktor Urumov

2011-07-06T23:59:59.000Z

323

Development and Application of Nonlinear PCA for Fault  

E-Print Network [OSTI]

Development and Application of Nonlinear PCA for Fault Diagnosis in Internal Combustion Engines Uwe to an Internal Combustion Engine · Conclusions and Future Challenges #12;Slide 3 Uwe Kruger Development Kruger School of Electronics, Electrical Engineering & Computer Science Ashby Building Stranmillis Road

Gorban, Alexander N.

324

Electrical faults modeling of the photovoltaic generator Wail Rezgui1  

E-Print Network [OSTI]

Electrical faults modeling of the photovoltaic generator Wail Rezgui1 , Leïla-Hayet Mouss1 , Kinza is captured by the generator and direct electrical energy resulting from the conversion of the solar radiation of a problem at the generator. Practically, the existence of electrical defects on this type of systems can

Boyer, Edmond

325

Test Case Purification for Improving Fault Localization Jifeng Xuan  

E-Print Network [OSTI]

Test Case Purification for Improving Fault Localization Jifeng Xuan INRIA Lille - Nord Europe Lille on the execution trace of test cases. Failing test cases and their assertions form test oracles for the failing behavior of the system under analysis. In this paper, we propose a novel concept of spectrum driven test

326

Statistical Approaches to Fault Analysis in Multivariate Process Control  

E-Print Network [OSTI]

Statistical Approaches to Fault Analysis in Multivariate Process Control Richard D. De Veaux Lyle H Abstract After a brief review of some statistical approaches to multivariate process control, we present analysis or partial least squares to limit the number of latent variables to study. While using historical

Ungar, Lyle H.

327

Influence of plastic deformation on bimaterial fault rupture directivity  

E-Print Network [OSTI]

Influence of plastic deformation on bimaterial fault rupture directivity Nora DeDontney,1 Elizabeth of the role of the stress state on the distribution of plastic deformation and the direction of preferred in determining the location of plastic deformation. For different orientations, plastic deformation can

Dmowska, Renata

328

On Fault Coverage of Tests for Finite State Specifications  

E-Print Network [OSTI]

On Fault Coverage of Tests for Finite State Specifications A. Petrenko and G. v. Bochmann-Ville, Montréal (Québec), H3C 3J7, Canada Abstract Testing is a trade-off between increased confidence in the correctness of the implementation under test and constraints on the amount of time and effort that can

von Bochmann, Gregor

329

Fault Detection Effectiveness of Spathic Test Data Jane Huffman Hayes  

E-Print Network [OSTI]

Fault Detection Effectiveness of Spathic Test Data Jane Huffman Hayes Computer Science Department This paper presents an approach for generating test data for unit-level, and possibly integration-level, testing based on sampling over intervals of the input probability distribution, i.e., one that has been

Hayes, Jane E.

330

Motion and evolution of the Chaochou Fault, Southern Taiwan  

E-Print Network [OSTI]

has been called the Chuchi Transfer Fault Zone (Lacombe et al., 2001). This boundary represents a major change in the character of seismicity in Taiwan. Although the nature of this boundary is not known, it may represent the southern extent of direct...

Hassler, Lauren E.

2005-11-01T23:59:59.000Z

331

Fault-tolerant architecture for quantum computation using electrically controlled  

E-Print Network [OSTI]

ARTICLES Fault-tolerant architecture for quantum computation using electrically controlled an architecture for quantum computation using electrically controlled semiconductor spins by extending the Loss in the solid state. Here, we develop a scalable architecture for solid-state quantum computation based

Loss, Daniel

332

Fracture surface energy of the Punchbowl fault, San Andreas system  

E-Print Network [OSTI]

Fracture surface energy of the Punchbowl fault, San Andreas system Judith S. Chester1 , Frederick M. Chester1 & Andreas K. Kronenberg1 Fracture energy is a form of latent heat required to create weakening1­3 . Fracture energy has been estimated from seismological and experimental rock deformation data4

Chester, Frederick M.

333

High voltage fault current limiter having immersed phase coils  

DOE Patents [OSTI]

A fault current limiter including: a ferromagnetic circuit formed from a ferromagnetic material and including at least a first limb, and a second limb; a saturation mechanism surrounding a limb for magnetically saturating the ferromagnetic material; a phase coil wound around a second limb; a dielectric fluid surrounding the phase coil; a gaseous atmosphere surrounding the saturation mechanism.

Darmann, Francis Anthony

2014-04-22T23:59:59.000Z

334

Module Placement for Fault-Tolerant Microfluidics-Based Biochips  

E-Print Network [OSTI]

Module Placement for Fault-Tolerant Microfluidics-Based Biochips FEI SU and KRISHNENDU CHAKRABARTY Duke University Microfluidics-based biochips are soon expected to revolutionize clinical diagnosis, DNA sequencing, and other laboratory procedures involving molecular biology. Most microfluidic biochips today

Chakrabarty, Krishnendu

335

Active Probing Approach for Fault Localization in Computer Networks*  

E-Print Network [OSTI]

to develop tools for performing fault localization. We discuss various design issues involved and propose architecture for building such a tool. We describe an algorithm for probe set selection for problem detection a wide range of activities involving network design and operation [7, 9, 17, 18]. Network monitoring can

Sethi, Adarshpal

336

Real Time Control Design for Mobile Robot Fault Tolerant Control.  

E-Print Network [OSTI]

Mobile Robot. Cristian Axenie Automation and Industrial Informatics Department Razvan Solea, Lecturer, Ph-time distributed control application with fault tolerance capabilities for differential wheeled mobile robots mobile robot the author has been able to develop a hierarchical software application that minimizes costs

Kuehnlenz, Kolja

337

Fault Tolerance on Interleaved inverter with Magnetic couplers  

E-Print Network [OSTI]

Fault Tolerance on Interleaved inverter with Magnetic couplers K.Guépratte, D.Frey, P-O.Jeannin, H Electrical Engineering (G2Elab), Thales Systemes Aeroportes Abstract- The paper focuses on a new control strategy for improving the availability of power electronic converters based on interleaved structures

Paris-Sud XI, Université de

338

Defects and Faults in Quantum Cellular Automata at Nano Scale  

E-Print Network [OSTI]

Defects and Faults in Quantum Cellular Automata at Nano Scale Mehdi Baradaran Tahoori, Mariam considerable research on quantum dot cellular automata (QCA) as a new computing scheme in the nano, quantum dot cellular automata (QCA) not only gives a solution at nano scale, but also it offers a new

339

Proceedings of the 18th Fault-Tolerant Computing Symposium  

E-Print Network [OSTI]

Proceedings of the 18th Fault-Tolerant Computing Symposium Tokyo, Japan, pp. 234-239, June 1988 performed on this erroneous information are ``undone'' using a hardware mechanism for fast rollback of a few and confine the damage caused by the error to the failed module, it is often necessary to check the outputs

Tamir, Yuval

340

This document contains 3087 words. FAULT-TOLERANT COMPUTING  

E-Print Network [OSTI]

or physical damage. An extensive methodology has been developed in this field over the past thirty years the annual IEEE International Symposium on Fault-Tolerant Computing (FTCS) and the papers in its Digests with protective redundancy so that, if the module fails, others can assume its function. Special mechanisms

Rennels, David A.

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Outlier Detection Rules for Fault Detection in Solar Photovoltaic Arrays  

E-Print Network [OSTI]

Abstract-- Solar photovoltaic (PV) arrays are unique power sources that may have uncleared fault current of solar photovoltaic (PV) systems. Different from traditional power sources, solar PV array is unique devices (OCPD). This may be caused by non-linear output characteristics of solar PV arrays, low irradiance

Lehman, Brad

342

Combining Tools for the Verification of FaultTolerant Systems  

E-Print Network [OSTI]

and verification of fault­tolerant systems according to the invent&verify paradigm. Our method is based on the CSP specifications (CSP process terms), refinement relations or combinations of these three description formalisms specification paradigms ac­ cording to the specific needs of each development step is essential to cope

Peleska, Jan - Fachbereich 3

343

Fault prediction in aircraft engines using Self-Organizing Maps  

E-Print Network [OSTI]

Fault prediction in aircraft engines using Self- Organizing Maps Marie Cottrell1 , Patrice Gaubert1. Aircraft engines are designed to be used during several tens of years. Their maintenance is a challenging and costly task, for obvious security reasons. The goal is to ensure a proper operation of the engines

Paris-Sud XI, Université de

344

Condition Assessment and Fault Prognostics of Microelectromechanical Systems  

E-Print Network [OSTI]

Condition Assessment and Fault Prognostics of Microelectromechanical Systems K. Medjaher , H. Skima-Mechatronic Systems Department 24, rue Alain Savary, 25000 Besançon, France Abstract Microelectromechanical systems to microelectromechanical systems (MEMS), since these latter devices undergo failures during their life- time. However

Paris-Sud XI, Université de

345

Wind Energy Conversion Systems Fault Diagnosis Using Wavelet Analysis  

E-Print Network [OSTI]

Wind Energy Conversion Systems Fault Diagnosis Using Wavelet Analysis Elie Al-Ahmar1,2 , Mohamed El, induction generator, Discrete Wavelet Transform (DWT), failure diagnosis. I. Introduction Wind energy the condition of induction machines. Fig. 1. Worldwide growth of wind energy installed capacity [1]. 1 E. Al

Paris-Sud XI, Université de

346

How to Generate Fault Trees from Causal In uence Diagrams  

E-Print Network [OSTI]

. 1 #12; Hydrocarbon in Steam in Catalyst in Vent 1 Vent 2 Product out Tank Pressure controller Handbook [VGRH81], written by some of the original developers of fault tree methodology in the nuclear; Explosion Pressure too high PRV 1 does not open PRV 2 does not open Valve failure Operator does not know

Ladkin, Peter B.

347

Permanent Magnets Synchronous Machines Faults Detection and Identification  

E-Print Network [OSTI]

for permanent magnet synchronous machines (PMSM). Two main faults occurring on these machines are identified of the PMSM is devel- oped and simulated using Matlab Simulink. The model enables simulating nominal and faulty PMSM behavior, with several stages of degradation, and is supported by tests results. Specific

Paris-Sud XI, Université de

348

ARM: Fractional cloud cover, clear-sky and all-sky shortwave flux for each of 25 individual SGP facilities.  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

Fractional cloud cover, clear-sky and all-sky shortwave flux for each of 25 individual SGP facilities.

Gaustad, Krista; Gaustad, Krista; McFarlane, Sally; McFarlane, Sally

349

Design of coupling for synchronization in time-delayed systems  

E-Print Network [OSTI]

We report a design of delay coupling for targeting desired synchronization in delay dynamical systems. We target synchronization, antisynchronization, lag-, antilag- synchronization, amplitude death (or oscillation death) and generalized synchronization in mismatched oscillators. A scaling of the size of an attractor is made possible in different synchronization regimes. We realize a type of mixed synchronization where synchronization, antisynchronization coexist in different pairs of state variables of the coupled system. We establish the stability condition of synchronization using the Krasovskii-Lyapunov function theory and the Hurwitz matrix criterion. We present numerical examples using the Mackey-Glass system and a delay R\\"{o}ssler system.

Dibakar Ghosh; Ioan Grosu; Syamal Kumar Dana

2012-07-03T23:59:59.000Z

350

Time dependence of delayed neutron emission for fissionable isotope identification  

SciTech Connect (OSTI)

The time dependence of delayed neutron emission was examined as a method of fissionable isotope identification. A pulsed bremsstrahlung photon beam was used to induce photofission reactions in {sup 238}U, {sup 232}Th, and {sup 239}Pu targets. The resulting delayed neutron emission was recorded between irradiating pulses and is a well-known technique for fissionable material detection. Monitoring the decay of delayed neutron emission between irradiating pulses demonstrates the ability to not only detect the presence of fissionable materials, but also to identify which fissionable isotope is present.

Kinlaw, M.T.; Hunt, A.W. [Idaho Accelerator Center, Idaho State University, Pocatello, Idaho 83209-8263 (United States); Department of Physics, Idaho State University, Pocatello, Idaho 83209-8106 (United States)

2005-06-20T23:59:59.000Z

351

Impact of delayed neutron precursor mobility in fissile solution systems  

SciTech Connect (OSTI)

A research version of the Monte Carlo software package MCNP6 is modified to incorporate advection and diffusion of delayed neutron precursors, resulting in the emission of delayed neutrons at locations different from the original fission sites. Results of two test problems, a pipe carrying flowing fissile solution and a sphere of fissile solution with precursor diffusion, show that the fission product mobility tends to perturb the fundamental mode, has a negative reactivity effect, and, perhaps most importantly, causes a decrease in the effective delayed neutron fraction. (authors)

Kiedrowski, B. C. [X-Computational Physics Div., Los Alamos National Laboratory, MS A143, P.O. Box 1663, Los Alamos, NM 87545 (United States)

2012-07-01T23:59:59.000Z

352

Thrust faulting in Temblor Range, Kern County, California  

SciTech Connect (OSTI)

Surface and subsurface studies confirm the presence of overthrusting in the Temblor Range between Gonyer Canyon and Recruit Pass. In the subsurface, three wells have penetrated the Cree fault, the Hudbay Cree' No. 1 (7,300 ft), the Frantzen Oil Company Cree' No. 1 (5,865 ft) and the Arco Cree Fee' 1A well (5,915 ft). Below the fault, 25 to 35{degree} of westerly dips on the west flank of the sub-thrust Phelps anticline are encountered. The McDonald section below the fault is comprised of siliceous fractured shale which contains live oil and gas showings. A drill-stem test of the interval from 8,247 to 8,510 ft in the Frantzen well resulted in a recovery of 1,200 ft clean 34{degree} oil and 40 MCF per day gas. The shut in pressure was 3,430 lb, which is a normal hydrostatic pressure common to the producing structures in the southern San Joaquin Valley. The equivalent of this interval has produced over 7,000 bbl of oil in the Arco Cree' 1A well. The Arco Cree Fee' No. 1A well crossed the axis of the Phelps Anticline as indicated by good dipmeter and bottomed in Lower Zemorrian at 14,512 ft total depth. This well was not drilled deep enough to reach the Point of Rocks Sand and did not test the gas showings in the lower Miocene section. In the Gonyer Canyon area, subsurface evidence indicated conditions are similar to those in the Cree area because a large structure is present below a thrust fault. It is believed that significant accumulations will be found beneath thrust faults in the eastern part of the Temblor Range where conditions are similar to those that were instrumental in forming fields such as the Elk Hills, B. V. Hills, Belgian Anticline and others.

Simonson, R.R.

1991-02-01T23:59:59.000Z

353

Proactive Fault Tolerance for HPC with Xen Virtualization  

SciTech Connect (OSTI)

with thousands of processors. At such large counts of compute nodes, faults are becoming common place. Current techniques to tolerate faults focus on reactive schemes to recover from faults and generally rely on a checkpoint/restart mechanism. Yet, in today's systems, node failures can often be anticipated by detecting a deteriorating health status. Instead of a reactive scheme for fault tolerance (FT), we are promoting a proactive one where processes automatically migrate from ?unhealthy? nodes to healthy ones. Our approach relies on operating system virtualization techniques exemplied by but not limited to Xen. This paper contributes an automatic and transparent mechanism for proactive FT for arbitrary MPI applications. It leverages virtualization techniques combined with health monitoring and load-based migration. We exploit Xen's live migration mechanism for a guest operating system (OS) to migrate an MPI task from a health-deteriorating node to a healthy one without stopping the MPI task during most of the migration. Our proactive FT daemon orchestrates the tasks of health monitoring, load determination and initiation of guest OS migration. Experimental results demonstrate that live migration hides migration costs and limits the overhead to only a few seconds making it an attractive approach to realize FT in HPC systems. Overall, our enhancements make proactive FT a valuable asset for long-running MPI application that is complementary to reactive FT using full checkpoint/ restart schemes since checkpoint frequencies can be reduced as fewer unanticipated failures are encountered. In the context of OS virtualization, we believe that this is the rst comprehensive study of proactive fault tolerance where live migration is actually triggered by health monitoring.

Nagarajan, Arun Babu [North Carolina State University; Mueller, Frank [North Carolina State University; Engelmann, Christian [ORNL; Scott, Stephen L [ORNL

2007-01-01T23:59:59.000Z

354

Colonization, clear-cutting, and cornfields: Rural migration and deforestation in The Sierra de Lacandn National Park, Petn, Guatemala  

E-Print Network [OSTI]

1 Colonization, clear-cutting, and cornfields: Rural migration and deforestation in The Sierra de variability in the amount of forest cleared in the sample. While the high deforestation group cleared an average of 13.6 hectares, or 49% of their forest during the time period, the low deforestation group

Lopez-Carr, David

355

Controlled-source electromagnetic mapping of a faulted sandstone aquifer in central Texas  

E-Print Network [OSTI]

across a fault (Randolph 1991), due to permeability reduction in the deformation zone, but in some cases can be enhanced along the fault slip plane (Antonellini and Aydin 1994), i. e. parallel to the fault. A knowledge of subsurface fault distributions... the electromagnetic response. Seaborne et al. (1979) interpreted the anomalies as the edge effect of thin horizontal sheets of low resistivity beds, as opposed to the high conductivity response of the material in a fault zone. In a similar study, Hazell er al...

Gorman, Erin Margaret

2012-06-07T23:59:59.000Z

356

Development of Asset Fault Signatures for Prognostic and Health Management in the Nuclear Industry  

SciTech Connect (OSTI)

Proactive online monitoring in the nuclear industry is being explored using the Electric Power Research Institute’s Fleet-Wide Prognostic and Health Management (FW-PHM) Suite software. The FW-PHM Suite is a set of web-based diagnostic and prognostic tools and databases that serves as an integrated health monitoring architecture. The FW-PHM Suite has four main modules: Diagnostic Advisor, Asset Fault Signature (AFS) Database, Remaining Useful Life Advisor, and Remaining Useful Life Database. This paper focuses on development of asset fault signatures to assess the health status of generator step-up generators and emergency diesel generators in nuclear power plants. Asset fault signatures describe the distinctive features based on technical examinations that can be used to detect a specific fault type. At the most basic level, fault signatures are comprised of an asset type, a fault type, and a set of one or more fault features (symptoms) that are indicative of the specified fault. The AFS Database is populated with asset fault signatures via a content development exercise that is based on the results of intensive technical research and on the knowledge and experience of technical experts. The developed fault signatures capture this knowledge and implement it in a standardized approach, thereby streamlining the diagnostic and prognostic process. This will support the automation of proactive online monitoring techniques in nuclear power plants to diagnose incipient faults, perform proactive maintenance, and estimate the remaining useful life of assets.

Vivek Agarwal; Nancy J. Lybeck; Randall Bickford; Richard Rusaw

2014-06-01T23:59:59.000Z

357

Analysis of Fault Permeability Using Mapping and Flow Modeling, Hickory Sandstone Aquifer, Central Texas  

SciTech Connect (OSTI)

Reservoir compartments, typical targets for infill well locations, are commonly created by faults that may reduce permeability. A narrow fault may consist of a complex assemblage of deformation elements that result in spatially variable and anisotropic permeabilities. We report on the permeability structure of a km-scale fault sampled through drilling a faulted siliciclastic aquifer in central Texas. Probe and whole-core permeabilities, serial CAT scans, and textural and structural data from the selected core samples are used to understand permeability structure of fault zones and develop predictive models of fault zone permeability. Using numerical flow simulation, it is possible to predict permeability anisotropy associated with faults and evaluate the effect of individual deformation elements in the overall permeability tensor. We found relationships between the permeability of the host rock and those of the highly deformed (HD) fault-elements according to the fault throw. The lateral continuity and predictable permeability of the HD fault elements enhance capability for estimating the effects of subseismic faulting on fluid flow in low-shale reservoirs.

Nieto Camargo, Jorge E., E-mail: jorge.nietocamargo@aramco.com; Jensen, Jerry L., E-mail: jjensen@ucalgary.ca [University of Calgary, Department of Chemical and Petroleum Engineering (Canada)

2012-09-15T23:59:59.000Z

358

E-Print Network 3.0 - av delay programming Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Complexity of Delay Management Technical Report 456, Department of Computer Science, ETH Zurich Summary: The Computational Complexity of Delay Management Technical Report 456,...

359

Formulation and solution of the delayed gamma dose rate problem using the concept of effective delayed gamma production cross section  

SciTech Connect (OSTI)

With appropriate approximations, the delayed gamma dose rate problem can be formulated in terms of the effective delayed gamma production cross section. The coupled neutron-delayed-gamma transport equations then take the same form as the coupled neutron-prompt-gamma transport equations and they can, therefore, be solved directly in the same manner. This eliminates the need for the tedious and error prone flux coupling step in conventional calculations. Mathematical formulation and solution algorithms are derived. The advantages of this method are illustrated by an example of its application in the solution of a practical design problem. 62 refs., 10 figs., 1 tab.

Liew, S.L.; Ku, L.P.

1989-06-01T23:59:59.000Z

360

Opportunities for Process Monitoring Techniques at Delayed Access Facilities  

SciTech Connect (OSTI)

Except for specific cases where the International Atomic Energy Agency (IAEA) maintains a continuous presence at a facility (such as the Japanese Rokkasho Reprocessing Plant), there is always a period of time or delay between the moment a State is notified or aware of an upcoming inspection, and the time the inspector actually enters the material balance area or facility. Termed by the authors as “delayed access,” this period of time between inspection notice and inspector entrance to a facility poses a concern. Delayed access also has the potential to reduce the effectiveness of measures applied as part of the Safeguards Approach for a facility (such as short-notice inspections). This report investigates the feasibility of using process monitoring to address safeguards challenges posed by delayed access at a subset of facility types.

Curtis, Michael M.; Gitau, Ernest TN; Johnson, Shirley J.; Schanfein, Mark; Toomey, Christopher

2013-09-20T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Preliminary Pulsing Experiments to Measure Delayed Neutron Emission Parameters  

SciTech Connect (OSTI)

Recent interest in delayed neutron parameters including comparisons between macroscopic (experimental) and microscopic (calculated) results have prompted a set of experiments using the 1MW Triga Reactor at the Texas A and M University (TAMU) Nuclear Science Center (NSC) designed to measure the complete set of seven-group delayed neutron parameters for several higher actinides. Operating the Nuclear Science Center Reactor (NSCR) in a pulsed mode, a complete set of delayed neutron parameters were measured for Np-237 and Am-243. The total delayed neutron yield per 100 fissions for Np-237 and Am-243 was found to be 1.14 {+-} 0.07 and 0.85 {+-} 0.05, respectively. Comparisons to previous measurements are made where such measurements are available.

Charlton, W.S.; Parish, T.A.; Raman, S.

1998-10-05T23:59:59.000Z

362

Robust crew pairing : delays analysis and implementation of optimization approaches  

E-Print Network [OSTI]

With increasing delays and airport congestion that disturb airline operations, the development of robust schedules is becoming crucial. Increased traffic and poor weather are a few of the causes of airport congestion, ...

Leroyer, Pierre, S.M. Massachusetts Institute of Technology

2006-01-01T23:59:59.000Z

363

Chimera and globally clustered chimera: Impact of time delay  

E-Print Network [OSTI]

Following a short report of our preliminary results [Phys. Rev. E 79, 055203(R) (2009)], we present a more detailed study of the effects of coupling delay in diffusively coupled phase oscillator populations. We find that coupling delay induces chimera and globally clustered chimera (GCC) states in delay coupled populations. We show the existence of multi-clustered states that act as link between the chimera and the GCC states. A stable GCC state goes through a variety of GCC states, namely periodic, aperiodic, long-- and short--period breathers and becomes unstable GCC leading to global synchronization in the system, on increasing time delay. We provide numerical evidence and theoretical explanations for the above results and discuss possible applications of the observed phenomena.

Sheeba, Jane H; Lakshmanan, M

2010-01-01T23:59:59.000Z

364

On delay-sensitive communication over wireless systems  

E-Print Network [OSTI]

consider a number of objectives. 1. Develop an integrated methodology for the analysis of wireless systems that support delay-sensitive applications based, in part, on large deviation theory. 2. Use this methodology to identify fundamental performance...

Liu, Lingjia

2009-05-15T23:59:59.000Z

365

Delayed neutron energy spectrum measurements of actinide waste isotopes  

E-Print Network [OSTI]

was irradiated using the Texas A&M Nuclear Science Center Reactor (NSCR). Three proton recoil detectors, operating individually, in conjunction with MCNP calculated response functions, were used to measure the delayed neutron energy spectra of each isotope...

Comfort, Christopher M.

2012-06-07T23:59:59.000Z

366

Utilization-based delay guarantee techniques and their applications  

E-Print Network [OSTI]

have become popular for both civilian and mission critical applications. The variable service capacity of a wireless link presents more of a challenge in providing delay-guaranteed services in wireless networks. Finally, we study ways to provide...

Wang, Shengquan

2009-05-15T23:59:59.000Z

367

additional delayed regional: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

results for five active galactic nuclei. We recovered velocity-delay maps using the maximum-entropy method for four objects: Mrk 335, Mrk 1501, 3C120, and PG2130+099. For the...

368

Clearing, Sanitizing, and Destroying Information System Storage Media, Memory Devices, and Other Related Hardware  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Notice establishes Department of Energy policy requirements and responsibilities for clearing, sanitizing, and destroying DOE information system storage media, memory devices, and other related hardware to ensure no unauthorized information can be retrieved and provides instructions for the same. DOE N 205.15, dated 3-18-05, extends this directive until 3-18-06. No cancellations. Canceled by DOE M 205.1-2.

2004-02-19T23:59:59.000Z

369

Clear@, , D HThe model is --eqn 12-14 in Bjornstad et al.  

E-Print Network [OSTI]

Clear@, , D HThe model is -- eqn 12-14 in Bjornstad et al. N0 HtL = Exp HL S HtL => N0 HtL = Exp HL + x2 + x3 x2 x1 + x2 + x3 x3 x1 + x2 + x3 0 y { zzzzzzzzzzzzzzzzzzzzz Bjornstad&al.nb 1 #12;H in Bjornstad et al. NOTE: the below is cast in terms of angular frequencies, w: w = 2 fL Id := Identity

370

On the Approximation of Distributed-Delay Control Laws  

E-Print Network [OSTI]

-dimensional internal feedback of the form P -P e-sh (here P is the delay-free plant and h is the loop delay) that aims can be replaced with . = Pa -P e-sh (modified/generalized Smith predictor), where Pa is a rational e-Agh (sI - Ag)-1 Bg. The finite impulse response (FIR) com- pletion h{G e-sh } of G e-sh is defined

Mirkin, Leonid

371

Device For Trapping Laser Pulses In An Optical Delay Line  

DOE Patents [OSTI]

A device for maintaining a high-energy laser pulse within a recirculating optical delay line for a period time to optimize the interaction of the pulse with an electron beam pulse train comprising closely spaced electron micropulses. The delay line allows a single optical pulse to interact with many of the electron micropulses in a single electron beam macropulse in sequence and for the introduction of additional optical pulses to interact with the micropulses of additional electron beam macropulses. The device comprises a polarization-sensitive beam splitter for admitting an optical pulse to and ejecting it from the delay line according to its polarization state, a Pockels cell to control the polarization of the pulse within the delay line for the purpose of maintaining it within the delay line or ejecting it from the delay line, a pair of focusing mirrors positioned so that a collimated incoming optical pulse is focused by one of them to a focal point where the pulse interacts with the electron beam and then afterwards the pulse is recollimated by the second focusing mirror, and a timing device which synchronizes the introduction of the laser pulse into the optical delay line with the arrival of the electron macropulse at the delay line to ensure the interaction of the laser pulse with a prescribed number of electron micropulses in sequence. In a first embodiment of the invention, the principal optical elements are mounted with their axes collinear. In a second embodiment, all principal optical elements are mounted in the configuration of a ring.

Yu, David U. L. (Rancho Palos Verdes, CA); Bullock, Donald L. (Los Angeles, CA)

1997-12-23T23:59:59.000Z

372

Technique for the identification of dominant delayed neutron precursors.  

SciTech Connect (OSTI)

A technique for the identification of delayed neutron precursors has been developed based on the product of cumulative yield and probability of neutron emission. The motivation behind this work is to fix the decay constants of delayed neutrons to those of the dominant delayed neutron precursors. The desirability of identifying a single set of decay constants that would apply to all fissionable isotopes and be independent of the neutron energy spectrum has been addressed by several authors. The main advantages of a fixed-decay constant representation are simplifying the analysis of epithemal and fast reactors with multiple fissioning isotopes, and improving the fit to experimental data while preserving the inferred positive reactivity scale associated with the original six-group representation. It is well known that 27 1 delayed neutron precursors exist, but only a select number of those precursors contribute significantly to the decay of delayed neutron. Using data compiled by England and Rider, which lists fission yield and probability of neutron emission values for the 27 1 known delayed neutron precursors in 32 fissioning systems, thirteen precursors were identified that are consistently dominant for alI fissioning systems.

Loaiza, D. J. (David J.); Haskin, E. (Eric)

2001-01-01T23:59:59.000Z

373

Delayed-fission properties of neutron-deficient americium nuclei  

SciTech Connect (OSTI)

Characteristics of the delayed-fission decay mode in light americium nuclei have been investigated. Measurements on the unknown isotopes {sup 230}Am and {sup 236}Am were attempted, and upper limits on the delayed-fission branches of these nuclei were determined. Evidence of the existence of {sup 236}Am was observed in radiochemical separations. Total kinetic energy and mass-yield distributions of the electron-capture delayed-fission mode were measured for {sup 232}Am (t{sub 1/2} = 1.31 {plus minus} 0.04 min) and for {sup 234}Am (t{sub 1/2} = 2.32 {plus minus} 0.08 min), and delayed-fission probabilities of 6.9 {times} 10{sup {minus}4} and 6.6 {times} 10{sup {minus}5}, respectively, were determined. The total kinetic energy and the asymmetric mass-yield distributions are typical of fission of mid-range actinides. No discernible influence of the anomalous triple-peaked mass division characteristic of the thorium-radium region was detected. Measurements of the time correlation between the electron-capture x-rays and the subsequent fission conform that the observed fissions arise from the electron-capture delayed-fission mechanism. Delayed fission has provided a unique opportunity to extend the range of low-energy fission studies to previously inaccessible regions. 71 refs., 44 figs., 13 tabs.

Hall, H.L. (California Univ., Berkeley, CA (USA). Dept. of Chemistry)

1989-10-23T23:59:59.000Z

374

Mechanical properties and fabric of the Punchbowl fault zone, California  

E-Print Network [OSTI]

) identification of source rocks and sediment transport directions for sedimentary rock units (Larsen, 1959; Pelka, 1971; Robinson and Woodburne, 1971; Woodburne and Golz, 1972; Farley and Ehlig, 1977; Barrows, 1979), and (3) regional mapping and correlation... at Santa Barbara Chairman of Advisory Committee: John M. Logan Field observations and experimental rock deformation techniques are used to characterize the deformational fabric and relative mechanical properties of a portion of the Punchbowl fault zone...

Chester, Frederick Michael

1983-01-01T23:59:59.000Z

375

Fault-tolerant quantum computing with color codes  

E-Print Network [OSTI]

We present and analyze protocols for fault-tolerant quantum computing using color codes. We present circuit-level schemes for extracting the error syndrome of these codes fault-tolerantly. We further present an integer-program-based decoding algorithm for identifying the most likely error given the syndrome. We simulated our syndrome extraction and decoding algorithms against three physically-motivated noise models using Monte Carlo methods, and used the simulations to estimate the corresponding accuracy thresholds for fault-tolerant quantum error correction. We also used a self-avoiding walk analysis to lower-bound the accuracy threshold for two of these noise models. We present and analyze two architectures for fault-tolerantly computing with these codes: one with 2D arrays of qubits are stacked atop each other and one in a single 2D substrate. Our analysis demonstrates that color codes perform slightly better than Kitaev's surface codes when circuit details are ignored. When these details are considered, we estimate that color codes achieve a threshold of 0.082(3)%, which is higher than the threshold of $1.3 \\times 10^{-5}$ achieved by concatenated coding schemes restricted to nearest-neighbor gates in two dimensions but lower than the threshold of 0.75% to 1.1% reported for the Kitaev codes subject to the same restrictions. Finally, because the behavior of our decoder's performance for two of the noise models we consider maps onto an order-disorder phase transition in the three-body random-bond Ising model in 2D and the corresponding random-plaquette gauge model in 3D, our results also answer the Nishimori conjecture for these models in the negative: the statistical-mechanical classical spin systems associated to the 4.8.8 color codes are counterintuitively more ordered at positive temperature than at zero temperature.

Andrew J. Landahl; Jonas T. Anderson; Patrick R. Rice

2011-08-29T23:59:59.000Z

376

Cockade breccia: Product of mineralisation along dilational faults  

E-Print Network [OSTI]

. Geological Society of America, Washington, D.C. 548 Bateman, A.M., 1924. Angular inclusions and replacement deposits. Economic Geology 19, 504–549 520. 550 Beck, R., 1903. Lehre von den Erzlagerstätten. 2nd Ed., Gebrüder Bornträger, Berlin. 551 Bélissont... Date: 6 June 2014 Revised Date: 29 August 2014 Accepted Date: 2 September 2014 Please cite this article as: Frenzel, M., Woodcock, N.H., Cockade breccia: Product of mineralisation along dilational faults, Journal of Structural Geology (2014), doi: 10...

Frenzel, Max; Woodcock, Nigel H.

2014-01-01T23:59:59.000Z

377

Gravity and fault structures, Long Valley caldera, California  

SciTech Connect (OSTI)

The main and catastrophic phase of eruption in Long Valley occurred 0.73 m.y. ago with the eruption of over 600 km/sup 3/ of rhyolitic magma. Subsequent collapse of the roof rocks produced a caldera which is now elliptical in shape, 32 km east-west by 17 km north-south. The caldera, like other large Quarternary silicic ash-flow volcanoes that have been studied by various workers, has a nearly coincident Bouguer gravity low. Earlier interpretations of the gravity anomaly have attributed the entire anomaly to lower density rocks filling the collapsed structure. However, on the basis of many additional gravity stations and supporting subsurface data from several new holes, a much more complex and accurate picture has emerged of caldera structure. From a three-dimensional inversion of the residual Bouguer gravity data we can resolve discontinuities that seem to correlate with extensions of pre-caldera faults into the caldera and faults associated with the ring fracture. Some of these faults are believed related to the present-day hydrothermal upflow zone and the zone of youngest volcanic activity within the caldera.

Carle, S.F.; Goldstein, N.E.

1987-07-01T23:59:59.000Z

378

Superconducting fault current-limiter with variable shunt impedance  

DOE Patents [OSTI]

A superconducting fault current-limiter is provided, including a superconducting element configured to resistively or inductively limit a fault current, and one or more variable-impedance shunts electrically coupled in parallel with the superconducting element. The variable-impedance shunt(s) is configured to present a first impedance during a superconducting state of the superconducting element and a second impedance during a normal resistive state of the superconducting element. The superconducting element transitions from the superconducting state to the normal resistive state responsive to the fault current, and responsive thereto, the variable-impedance shunt(s) transitions from the first to the second impedance. The second impedance of the variable-impedance shunt(s) is a lower impedance than the first impedance, which facilitates current flow through the variable-impedance shunt(s) during a recovery transition of the superconducting element from the normal resistive state to the superconducting state, and thus, facilitates recovery of the superconducting element under load.

Llambes, Juan Carlos H; Xiong, Xuming

2013-11-19T23:59:59.000Z

379

Telluric Survey At Clear Lake Area (Skokan, 1993) | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia:FAQ < RAPID Jump to:Seadov Pty LtdSteen,Ltd Jump to:Taos County,Tees Valley(Newman,Telluric Survey At Clear

380

An expert system for fault section diagnosis of power systems using fuzzy relations  

SciTech Connect (OSTI)

This paper proposes an expert system using fuzzy relations to deal with uncertainties imposed on fault section diagnosis of power systems. The authors build sagittal diagrams which represent the fuzzy relations for power systems, and diagnose fault sections using the sagittal diagrams. Next, they examine the malfunction or wrong alarm of relays and circuit breakers based on the alarm information and the estimated fault section. The proposed system provides the fault section candidates in terms of the degree of membership and the malfunction or wrong alarm. An operator monitors these candidates and is able to diagnose the fault section, coping with uncertainties. Experimental studies for real power systems reveal usefulness of the proposed technique to diagnose faults that have uncertainty.

Cho, H.J. [LG Electronics Research Center, Seoul (Korea, Republic of); Park, J.K. [Seoul National Univ. (Korea, Republic of). Dept. of Electrical Engineering

1997-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

A High-Resolution Aeromagnetic Survey to Identify Buried Faults at Dixie Valley, Nevada  

SciTech Connect (OSTI)

Preliminary results from a high-resolution aeromagnetic survey (200m line spacing) acquired in Dixie Valley early in 2002 provide confirmation of intra-basin faulting based on subtle surface indications. In addition the data allow identification of the locations and trends of many faults that have not been recognized at the surface, and provide a picture of intrabasin faulting patterns not possible using other techniques. The data reveal a suite of northeasterly-trending curving and branching faults that surround a relatively coherent block in the area of Humboldt Salt Marsh, the deepest part of the basin. The producing reservoir occurs at the north end of this coherent block, where rampart faults from the northwest side of the valley merge with anthithetic faults from the central and southeast parts of the valley.

Smith, Richard Paul; Grauch, V. J. S.; Blackwell, David D.

2002-09-01T23:59:59.000Z

382

Multi-rhythmicity in an optoelectronic oscillator with large delay  

E-Print Network [OSTI]

An optoelectronic oscillator exhibiting a large delay in its feedback loop is studied both experimentally and theoretically. We show that multiple square-wave oscillations may coexist for the same values of the parameters (multi-rhythmicity). Depending on the sign of the phase shift, these regimes admit either periods close to an integer fraction of the delay or periods close to an odd integer fraction of twice the delay. These periodic solutions emerge from successive Hopf bifurcation points and stabilize at a finite amplitude following a scenario similar to Eckhaus instability in spatially extended systems. We find quantitative agreements between experiments and numerical simulations. The linear stability of the square-waves is substantiated analytically by determining stable fixed points of a map.

Weicker, Lionel; Rosin, David P; Gauthier, Daniel J

2014-01-01T23:59:59.000Z

383

Pulsed Photofission Delayed Gamma Ray Detection for Nuclear Material Identification  

SciTech Connect (OSTI)

Innovative systems with increased sensitivity and resolution are in great demand to detect diversion and to prevent misuse in support of nuclear materials management for the U.S. fuel cycle. Nuclear fission is the most important multiplicative process involved in non-destructive active interrogation. This process produces the most easily recognizable signature for nuclear materials. High-energy gamma rays can also excite a nucleus and cause fission through a process known as photofission. After photofission reactions, delayed signals are easily distinguishable from the interrogating radiation. Linac-based, advanced inspection techniques utilizing the fission signals after photofission have been extensively studied for homeland security applications. Previous research also showed that a unique delayed gamma ray energy spectrum exists for each fissionable isotope. Isotopic composition measurement methods based on delayed gamma ray spectroscopy will be the primary focus of this work.

John Kavouras; Xianfei Wen; Daren R. Norman; Dante R. Nakazawa; Haori Yang

2012-11-01T23:59:59.000Z

384

Gels under stress: the origins of delayed collapse  

E-Print Network [OSTI]

Attractive colloidal particles can form a disordered elastic solid or gel when quenched into a two-phase region, if the volume fraction is sufficiently large. When the interactions are comparable to thermal energies the stress-bearing network within the gel restructures over time as individual particle bonds break and reform. Typically, under gravity such weak gels show a prolonged period of either no or very slow settling, followed by a sudden and rapid collapse - a phenomenon known as delayed collapse. The link between local bond breaking events and the macroscopic process of delayed collapse is not well understood. Here we summarize the main features of delayed collapse and discuss the microscopic processes which cause it. We present a plausible model which connects the kinetics of bond breaking to gel collapse and test the model by exploring the effect of an applied external force on the stability of a gel.

Lisa J. Teece; James M. Hart; Kerry Yen Ni Hsu; Stephen Gilligan; Malcolm A. Faers; Paul Bartlett

2014-03-12T23:59:59.000Z

385

Influence of faults on groundwater flow and transport at YuccaMountain, Nevada  

SciTech Connect (OSTI)

Numerical simulations of groundwater flow at Yucca Mountain, Nevada are used to investigate how faults influence groundwater flow pathways and regional-scale macrodispersion. The 3-D model has a unique grid block discretization that facilitates the accurate representation of the complex geologic structure present in faulted formations. Each hydrogeologic layer is discretized into a single layer of irregular and dipping grid blocks, and faults are discretized such that they are laterally continuous and varied in displacement varies along strike. In addition, the presence of altered fault zones is explicitly modeled, as appropriate. Simulations show that upward head gradients can be readily explained by the geometry of hydrogeologic layers, the variability of layer permeabilities, and the presence of permeable fault zones or faults with displacement only, not necessarily by upwelling from a deep aquifer. Large-scale macrodispersion results from the vertical and lateral diversion of flow near the contact of high- and low-permeability layers at faults, and from upward flow within high-permeability fault zones. Conversely, large-scale channeling can occur as a result of groundwater flow into areas with minimal fault displacement. Contaminants originating at the water table can flow in a direction significantly different from that of the water table gradient, and isolated zones of contaminants can occur at the water table downgradient. By conducting both 2-D and 3-D simulations, we show that the 2-D cross-sectional models traditionally used to examine flow in faulted formations may not be appropriate. In addition, the influence of a particular type of fault cannot be generalized; depending on the location where contaminants enter the saturated zone, faults may either enhance or inhibit vertical dispersion.

Cohen, Andrew J.B.; Sitar, Nicholas

1999-10-07T23:59:59.000Z

386

Performance Study of Enhanced Auto-Associative Neural Networks For Sensor Fault Detection  

E-Print Network [OSTI]

- INTRODUCTION When sensors malfunction, control systems become unreliable. Even with the most sophisticated instruments and control algorithms, a control decision based on faulty data will likely lead to incorrect control actions. ?Sensor Fault Detection...? is usually considered as a subset of fault detection. One of the well known approaches in Fault Detection is the model based approach in which a computational model is designed to predict the real system output while receiving the same input ([7], [8...

Najafi, M.; Culp, C.; Langari, R.

2004-01-01T23:59:59.000Z

387

Method of detecting the direction of arcing faults on power distribution feeders  

E-Print Network [OSTI]

harmonic symmetrical current components under high impedance arcing faults hss been proposed by Raiser of Power Technologies Inc [I]. Other methods using even, odd, and "in-between" harmonics (with respect to the 60 Hz fundamental frequency) have been... and the second based on the "in-between" harmonic frequency current correlation to the voltage of the faulted feeder [8]. Benner has proposed the correlation of voltage to the difference in line current, caused due to an arcing high impedance fault...

Fernando, W. Anand Krisantha

1992-01-01T23:59:59.000Z

388

SciTech Connect: Development of Asset Fault Signatures for Prognostic...  

Office of Scientific and Technical Information (OSTI)

signatures to assess the health status of generator step-up generators and emergency diesel generators in nuclear power plants. Asset fault signatures describe the distinctive...

389

E-Print Network 3.0 - andreas fault system Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

are approximately three times... OF DEVIATORIC STRESS ALONG THE SAN ANDREAS FAULT B. R. Smith (1), D. T. Sandwell (1) (1) IGPP, Scripps... along the San Andreas system ......

390

E-Print Network 3.0 - adaptive fault detection Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

or fault-free path. Therefore, the issue... present a technique to enhance minimal, fully-adaptive routing al- gorithms ... Source: Boppana, Rajendra V. - Department of Computer...

391

E-Print Network 3.0 - algorithmic fault tree Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

based on fault trees derived using the IFT induction algorithm. The test system is a robot arm... University College Galway, Ireland. 12;INDUCTION AND THE IFT ALGORITHM To...

392

Microsoft Word - GroundFaultSAND-rev7-JJ.doc  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3459 Unlimited Release Printed June 2013 Photovoltaic Ground Fault and Blind Spot Electrical Simulations Jack D. Flicker Jay Johnson Prepared by Sandia National Laboratories...

393

Wind Power Plant Enhancement with a Fault-Current Limiter: Preprint  

SciTech Connect (OSTI)

This paper investigates the capability of a saturable core fault-current limiter to limit the short circuit current of different types of wind turbine generators.

Muljadi, E.; Gevorgian, V.; DeLaRosa, F.

2011-03-01T23:59:59.000Z

394

E-Print Network 3.0 - achieve fault tolerance Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3 This document contains 3087 words. FAULT-TOLERANT COMPUTING Summary: -the-shelf computers and achieved voting and reconfiguration primarily through software. The second...

395

Fault Tolerance Techniques for Wireless Ad Hoc Sensor Networks Farinaz Koushanfar  

E-Print Network [OSTI]

poten- tial to provide inexpensive and pervasive bridge between physical and computational worlds and actuators that have significantly higher fault rates than the traditional semiconductor integrated circuits

396

Finite-difference modeling of faults and fractures Richard T. Coates ...  

E-Print Network [OSTI]

For the purposes of seismic propagation, a slip fault may be regarded as a surface across which the dis- placement caused by a seismic wave is discontinuous.

2010-06-09T23:59:59.000Z

397

E-Print Network 3.0 - atera fault central Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The Netherlands ABSTRACT Faults strongly impact groundwater ow... in the unconsolidated sediments of the Lower Rhine Embayment. Hydraulic head maps show that many...

398

Fault-Based Attack of RSA Authentication Andrea Pellegrini, Valeria Bertacco and Todd Austin  

E-Print Network [OSTI]

a straightforward design architecture that en- tails a small silicon footprint and low-power profile. Our research enviromental manipulations. Our fault-based attack can be succ

Austin, Todd M.

399

E-Print Network 3.0 - aircraft fault detection Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

the next 3 years, we cannot use... aircrafts to detect faults on our new ones. Fuzzy logic converts expert knowledge (usually, rules... ), expressed in natural language, into...

400

E-Print Network 3.0 - automatical adaptive fault Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

and Information Sciences 50 FUSE -A HARDWARE ACCELERATED HDL FAULT INJECTION TOOL Marcus Jeitler, Martin Delvai Summary: the Hpe desk environment has 12;Fig. 3. FuSE...

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Coulomb stress accumulation along the San Andreas Fault system Bridget Smith and David Sandwell  

E-Print Network [OSTI]

Coulomb stress accumulation along the San Andreas Fault system Bridget Smith and David Sandwell deformation, SCEC velocities, crustal stress Citation: Smith, B., and D. Sandwell, Coulomb stress accumulation

Smith-Konter, Bridget

402

Delayed pulsar kicks from the emission of sterile neutrinos  

SciTech Connect (OSTI)

The observed velocities of pulsars suggest the possibility that sterile neutrinos with mass of several keV are emitted from a cooling neutron star. The same sterile neutrinos could constitute all or part of cosmological dark matter. The neutrino-driven kicks can exhibit delays depending on the mass and the mixing angle, which can be compared with the pulsar data. We discuss the allowed ranges of sterile neutrino parameters, consistent with the latest cosmological and x-ray bounds, which can explain the pulsar kicks for different delay times.

Kusenko, Alexander; Mandal, Bhabani Prasad; Mukherjee, Alok [Department of Physics and Astronomy, University of California, Los Angeles, CA 90095-1547 (United States); Department of Physics, Banaras Hindu University, Varanasi-221005 (India)

2008-06-15T23:59:59.000Z

403

Time delayed laser networks: phase versus chaos synchronization  

E-Print Network [OSTI]

The synchronization of chaotic lasers and the optical phase synchronization of light originating in multiple coupled lasers have both been extensively studied, however, the interplay between these two phenomena, especially at the network level is unexplored. Here we experimentally compare chaos synchronization of laser networks with heterogeneous coupling delay times to phase synchronization of similar networks. While chaotic lasers exhibit deterioration in synchronization as the network time delay heterogeneity increases, phase synchronization is found to be independent of heterogeneity. The experimental results are found to be in agreement with numerical simulations for semiconductor lasers.

Reidler, I; Aviad, Y; Guberman, S; Friesem, A A; Rosenbluh, M; Davidson, N; Kanter, I

2013-01-01T23:59:59.000Z

404

Time delayed laser networks: phase versus chaos synchronization  

E-Print Network [OSTI]

The synchronization of chaotic lasers and the optical phase synchronization of light originating in multiple coupled lasers have both been extensively studied, however, the interplay between these two phenomena, especially at the network level is unexplored. Here we experimentally compare chaos synchronization of laser networks with heterogeneous coupling delay times to phase synchronization of similar networks. While chaotic lasers exhibit deterioration in synchronization as the network time delay heterogeneity increases, phase synchronization is found to be independent of heterogeneity. The experimental results are found to be in agreement with numerical simulations for semiconductor lasers.

I. Reidler; M. Nixon; Y. Aviad; S. Guberman; A. A. Friesem; M. Rosenbluh; N. Davidson; I. Kanter

2013-04-03T23:59:59.000Z

405

Optical position sensor for determining the interface between a clear and an opaque fluid  

DOE Patents [OSTI]

An inexpensive, optical position sensor for measuring a position or length, x, along a one-dimensional curvilinear, coordinate system. The sensor can be used, for example, to determine the position of an interface between a clear and an opaque fluid (such as crude oil and water). In one embodiment, the sensor utilizes the principle of dual-fluorescence, where a primary fiber emits primary fluorescent light and a parallel secondary fiber collects a portion of the primary fluorescent light that is not blocked by the opaque fluid. This, in turn, excites secondary fluorescence in the secondary fiber at a longer wavelength. A light detector measures the intensity of secondary fluorescence emitted from an end of the secondary fiber, which is used to calculate the unknown position or length, x. Side-emitting fibers can be used in place of, or in addition to, fluorescent fibers. The all-optical sensor is attractive for applications involving flammable liquids.

Weiss, Jonathan D. (Albuquerque, NM)

2006-05-23T23:59:59.000Z

406

Transverse slope of bed and turbid-clear water interface of channelized turbidity currents flowing around bends  

E-Print Network [OSTI]

1 Transverse slope of bed and turbid-clear water interface of channelized turbidity currents is assumed to be Froude-subcritical, and in the case of a turbidity current a relatively sharp interface between turbid water and clear water above is assumed. The analysis focuses on the processes that maintain

Parker, Gary

407

Coordinated Fault-Tolerance for High-Performance Computing Final Project Report  

SciTech Connect (OSTI)

With the Coordinated Infrastructure for Fault Tolerance Systems (CIFTS, as the original project came to be called) project, our aim has been to understand and tackle the following broad research questions, the answers to which will help the HEC community analyze and shape the direction of research in the field of fault tolerance and resiliency on future high-end leadership systems. #15; Will availability of global fault information, obtained by fault information exchange between the different HEC software on a system, allow individual system software to better detect, diagnose, and adaptively respond to faults? If fault-awareness is raised throughout the system through fault information exchange, is it possible to get all system software working together to provide a more comprehensive end-to-end fault management on the system? #15; What are the missing fault-tolerance features that widely used HEC system software lacks today that would inhibit such software from taking advantage of systemwide global fault information? #15; What are the practical limitations of a systemwide approach for end-to-end fault management based on fault awareness and coordination? #15; What mechanisms, tools, and technologies are needed to bring about fault awareness and coordination of responses on a leadership-class system? #15; What standards, outreach, and community interaction are needed for adoption of the concept of fault awareness and coordination for fault management on future systems? Keeping our overall objectives in mind, the CIFTS team has taken a parallel fourfold approach. #15; Our central goal was to design and implement a light-weight, scalable infrastructure with a simple, standardized interface to allow communication of fault-related information through the system and facilitate coordinated responses. This work led to the development of the Fault Tolerance Backplane (FTB) publish-subscribe API specification, together with a reference implementation and several experimental implementations on top of existing publish-subscribe tools. #15; We enhanced the intrinsic fault tolerance capabilities representative implementations of a variety of key HPC software subsystems and integrated them with the FTB. Targeting software subsystems included: MPI communication libraries, checkpoint/restart libraries, resource managers and job schedulers, and system monitoring tools. #15; Leveraging the aforementioned infrastructure, as well as developing and utilizing additional tools, we have examined issues associated with expanded, end-to-end fault response from both system and application viewpoints. From the standpoint of system operations, we have investigated log and root cause analysis, anomaly detection and fault prediction, and generalized notification mechanisms. Our applications work has included libraries for fault-tolerance linear algebra, application frameworks for coupled multiphysics applications, and external frameworks to support the monitoring and response for general applications. #15; Our final goal was to engage the high-end computing community to increase awareness of tools and issues around coordinated end-to-end fault management.

Panda, Dhabaleswar Kumar [The Ohio State University; Beckman, Pete

2011-07-01T23:59:59.000Z

408

Waste Management Fault Tree Data Bank (WM): 1992 status report  

SciTech Connect (OSTI)

The Risk Assessment Methodology Group (RAM) of the Nuclear Process Safety Research Section (NPSR) maintains a compilation of incidents that have occurred in the Waste Management facilities. The Waste Management Fault Tree Data Bank (WM) contains more than 35,000 entries ranging from minor equipment malfunctions to incidents with significant potential for injury or contamination of personnel. This report documents the status of the WM data bank including: availability, training, source of data, search options, and usage, to which these data have been applied. Periodic updates to this memorandum are planned as additional data or applications are acquired.

Baughman, D.F.; Hang, P.; Townsend, C.S.

1993-08-30T23:59:59.000Z

409

Sandia National Laboratories: arc-fault circuit interrupter  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmosphericNuclear Security Administration the1development Sandia, NREL Release Wavearc-fault circuit interrupter Sandia Research on

410

An expert system for fault detection and diagnosis  

E-Print Network [OSTI]

to thank Dr. Ali Abur for his help in setting Eb1TP simulations. I would also lilre to thank Charles Fromen and Don Sevcik both with HLtrP Houston for providing invaluable expertise used in this thesis. TABLE OF CONTENTS CHAPTER Page INTRODUCTION . A... IV EXPERT SYSTEM DESIGN . . A. Introduction B. Rochester DFR Conversion C. EMTP Output File Conversion 46 46 47 54 vn1 CHAPTER Page VI D. Signal Analysis: MATI, AB . E. Fault Diagnosis: CLIPS F. Waveform Presentation: MATLAB G...

Spasojevic, Predrag

1992-01-01T23:59:59.000Z

411

Award ER25750: Coordinated Infrastructure for Fault Tolerance Systems Indiana University Final Report  

SciTech Connect (OSTI)

The main purpose of the Coordinated Infrastructure for Fault Tolerance in Systems initiative has been to conduct research with a goal of providing end-to-end fault tolerance on a systemwide basis for applications and other system software. While fault tolerance has been an integral part of most high-performance computing (HPC) system software developed over the past decade, it has been treated mostly as a collection of isolated stovepipes. Visibility and response to faults has typically been limited to the particular hardware and software subsystems in which they are initially observed. Little fault information is shared across subsystems, allowing little flexibility or control on a system-wide basis, making it practically impossible to provide cohesive end-to-end fault tolerance in support of scientific applications. As an example, consider faults such as communication link failures that can be seen by a network library but are not directly visible to the job scheduler, or consider faults related to node failures that can be detected by system monitoring software but are not inherently visible to the resource manager. If information about such faults could be shared by the network libraries or monitoring software, then other system software, such as a resource manager or job scheduler, could ensure that failed nodes or failed network links were excluded from further job allocations and that further diagnosis could be performed. As a founding member and one of the lead developers of the Open MPI project, our efforts over the course of this project have been focused on making Open MPI more robust to failures by supporting various fault tolerance techniques, and using fault information exchange and coordination between MPI and the HPC system software stack?from the application, numeric libraries, and programming language runtime to other common system components such as jobs schedulers, resource managers, and monitoring tools.

Lumsdaine, Andrew

2013-03-08T23:59:59.000Z

412

A DELAYED NONLINEAR PBPK MODEL FOR GENISTEIN DOSIMETRY IN RATS  

E-Print Network [OSTI]

A DELAYED NONLINEAR PBPK MODEL FOR GENISTEIN DOSIMETRY IN RATS #3; MICHAEL G. ZAGER y , HIEN T on laboratory animals and human volunteers [4], and critical literature reviews [32]. Phytoestrogens, a class endocrine-related e#11;ects such as reduced birth weight in rats and humans. In its conjugated form

413

Kalman filter analysis of delayed neutron nondestructive assay measurements.  

SciTech Connect (OSTI)

The ability to nondestructively determine the presence and quantity of fissile and fertile nuclei in various matrices is important in several nuclear applications including international and domestics safeguards, radioactive waste characterization and nuclear facility operations. Material irradiation followed by delayed neutron counting is a well known and useful nondestructive assay technique used to determine the fissile-effective content of assay samples. Previous studies have demonstrated the feasibility of using Kalman filters to unfold individual isotopic contributions to delayed neutron measurements resulting from the assay of mixes of uranium and plutonium isotopes. However, the studies in question used simulated measurement data and idealized parameters. We present the results of the Kalman filter analysis of several measurements of U/Pu mixes taken using Argonne National Laboratory's delayed neutron nondestructive assay device. The results demonstrate the use of Kalman filters as a signal processing tool to determine the fissile and fertile isotopic content of an assay sample from the aggregate delayed neutron response following neutron irradiation.

Aumeier, S. E.

1998-04-29T23:59:59.000Z

414

Electron-capture delayed fission properties of {sup 242}Es  

SciTech Connect (OSTI)

Electron-capture delayed fission of {sup 242}Es produced via the {sup 233}U({sup 14}N,5n){sup 242}Es reaction at 87 MeV (on target) was observed to decay with a half-life of 11{+-}3 s, consistent with the reported {alpha}-decay half-life of {sup 242}Es of 16{sub -4}{sup +6} s. The mass-yield distribution of the fission fragments is highly asymmetric. The average pre-neutron emission total kinetic energy of the fragments was measured to be 183{+-}18 MeV. Based on the ratio of the measured number of fission events to the measured number of {alpha} decays from the electron-capture daughter {sup 242}Cf (100% {alpha} branch), the probability of delayed fission was determined to be 0.006{+-}0.002. This value for the delayed fission probability fits the experimental trend of increasing delayed fission probability with increasing Q value for electron capture. (c) 2000 The American Physical Society.

Shaughnessy, D. A. [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States) [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States); Chemistry Department, University of California, Berkeley, California 94720 (United States); Adams, J. L. [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States) [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States); Gregorich, K. E. [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States) [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States); Lane, M. R. [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States) [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States); Laue, C. A. [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States) [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States); Lee, D. M. [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States) [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States); McGrath, C. A. [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States) [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States); Patin, J. B. [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States) [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States); Strellis, D. A. [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States) [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States); Sylwester, E. R. [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States) [Nuclear Science Division, Lawrence Berkeley National Laboratory, MS 70-319, Berkeley, California 94720 (United States); Chemistry Department, University of California, Berkeley, California 94720 (United States)] (and others)

2000-04-01T23:59:59.000Z

415

Delayed Gamma-Ray Spectroscopy for Spent Nuclear Fuel Assay  

SciTech Connect (OSTI)

High-energy, beta-delayed gamma-ray spectroscopy is investigated as a non-destructive assay technique for the determination of plutonium mass in spent nuclear fuel. This approach exploits the unique isotope-specific signatures contained in the delayed gamma-ray emission spectra detected following active interrogation with an external neutron source. A high fidelity modeling approach is described that couples radiation transport, analytical decay/depletion, and a newly developed gamma-ray emission source reconstruction code. Initially simulated and analyzed was a “one-pass” delayed gamma-ray assay that focused on the long-lived signatures. Also presented are the results of an independent study that investigated “pulsed mode” measurements, to capture the more isotope-specific, short-lived signatures. Initial modeling results outlined in this paper suggest that delayed gamma-ray assay of spent nuclear fuel assemblies can be accomplished with a neutron generator of sufficient strength and currently available gamma-ray detectors.

Campbell, Luke W.; Hunt, Alan W.; Ludewigt, Bernhard A.; Mozin, Vladimir V.

2012-04-01T23:59:59.000Z

416

Ultra LowVoltage Delay Locked Loop Using Carbon Nanotubes  

E-Print Network [OSTI]

Ultra LowVoltage Delay Locked Loop Using Carbon Nanotubes J.S. Ajit Northeastern University Dept, MA 02115 E-mail: ybk@ece.neu.edu AbstractCarbon Nanotube FET technology is investigated for both the shrinking process to continue, and for the development of novel architectures, is the carbon

Ayers, Joseph

417

Dynamics of connected vehicle systems with delayed acceleration feedback  

E-Print Network [OSTI]

predecessor is measured by radar and the vehicle is actuated accordingly. Since the delay in these systems conclusions are verified by simulations at the nonlinear level. Ã? 2014 Elsevier Ltd. All rights reserved. 1 limited ability to change the dynamics at the system level, which is necessary if one wishes to eliminate

Daly, Samantha

418

Delayed neutron emission measurements for U-235 and Pu-239  

E-Print Network [OSTI]

The delayed neutron emission rates of U-235 and Pu-239 samples were measured accurately from a thermal fission reaction. A Monte Carlo calculation using the Geant4 code was used to demonstrate the neutron energy independence of the detector used...

Chen, Yong

2009-05-15T23:59:59.000Z

419

MANAGING WIRE DELAY IN CHIP MULTIPROCESSOR CACHES Bradford M. Beckmann  

E-Print Network [OSTI]

. In contrast, transmission lines can reduce on-chip wire delay by an order of magnitude versus conventional wires and provide low latency to all shared cache banks. We demonstrate on-chip transmission lines provided by transmission lines and reduce off-chip misses versus a design using conventional wires. We

Wood, David A.

420

Extending Qualitative Modelling for Simulation of TimeDelayed Behaviour  

E-Print Network [OSTI]

industrial plants is to choose a measured variable and maintain the re­ quired value of this variable through a process of mea­ surement, comparison, and adjustment. A time delay between a disturbance in the plant applicable to simulators that enable synchronous tracking. The rest of this paper is arranged as follows

Miguel, Ian

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Delay analysis of bursty tasks using workload arrival functions  

E-Print Network [OSTI]

and the integrated methodologies with variable workloads are introduced. However, these methodologies have some limitations when they are applied to task systems instead of traffic. In this thesis, we propose that the end-to-end delay computed by the decomposed...

Kim, Junwhan

2001-01-01T23:59:59.000Z

422

Task Assignment in a Server Farm with Switching Delays and  

E-Print Network [OSTI]

costs Holding costs (per job) Objective to balance between Energy consumption Performance (e.g., latency Energy- and Delay-aware cost structure Switching costs Running costs Holding costs (per job) Objective to balance between Energy consumption Performance (e.g., latency) Heterogeneous servers, job-specific costs

Hyytiä, Esa

423

Efficient Path Delay Test Generation with Boolean Satisfiability  

E-Print Network [OSTI]

delay test generator CodGen. A mixed structural-functional approach was implemented in CodGen where longest paths were detected using the K Longest Path Per Gate (KLPG) algorithm and path justification and dynamic compaction were handled with the SAT...

Bian, Kun

2013-12-10T23:59:59.000Z

424

Practical delay modeling of externally recirculated burned gas fraction for  

E-Print Network [OSTI]

stringent norms on fuel consumption and pollutant emissions for automotive engines have substantially- setts Avenue, Cambridge MA 02139, USA e-mail: dbp@mit.edu Thomas Leroy and Jonathan Chauvin IFP Energies a significant delay trans- port which should be taken into account to accurately estimate and control the (dis

425

Fast amplitude and delay measurement for characterization of optical devices  

E-Print Network [OSTI]

to determine the chromatic dispersion in the device under test by taking the derivative of the group delay with respect to optical wavelength. The measurement setup allows both step-tunable and sweeping laser sources. A modulation frequency of up to 2.7 GHz...

Thompson, Michael Thomas

2006-10-30T23:59:59.000Z

426

Turbo King: Framework for Large-Scale Internet Delay Measurements  

E-Print Network [OSTI]

servers (which is called cache pollution) and requires large traffic overhead when deployed in large consuming half the bandwidth needed by King and reducing the impact of cache pollution by several orders building an all-to-all delay matrix between approximately 220, 000 BGP prefixes advertised in the Internet

Loguinov, Dmitri

427

A study of microstrip delay lines on high dielectric constant substrates  

E-Print Network [OSTI]

. . . . 83 VII. B. Conclusions. . . . . REFERENCES . . VITA . . . . 87 LIST OF FIGURES FIGURE Page 1 A 578ps delay line on CB material 2 A 1, 200 ps spiral delay line on duroid. . 19 3 274 ps delay lines on duroid with thickness, h, of (a) 10 mils... and (b) 5 mila. . . . 20 4 S-parameter data of 274 ps delay lines having h of (a)10 mils and (b) 5 mils. . . 22 5 Microstrip delay line test setup. . . 25 6 Top and side view of test fixture, launchers, and delay circuit. . . . . . . . . . 25 7 The (a...

Ashour, Thomas Joseph

1996-01-01T23:59:59.000Z

428

Field comparisons of direct and component measurements of net radiation under clear skies  

SciTech Connect (OSTI)

Accurate measurements of net radiation are basic to all studies of the surface energy budget. In preparation for an energy budget experiment significant differences were found between direct and component measurement of net radiation, which prompted this investigation of their cause. The instruments involved were an all-black single-dome Fritschen-type net pyrradiometer, two Eppley model 8-48 pyranometers, and an Eppley model PIR pyrgeometer. Each had recently been calibrated. The accuracy of the component instruments was considered first. Comparisons of about one hour on each of three nights between the pyrgeometer and five empirical formulas showed that the average departure over all formulas from the pyrgeometer average was {minus}1%. Other comparisons between the pyrgeometer and an infrared thermometer viewing the surface yielded similar results. Alternate shading and unshading of the pyrgeometer looking upward during daytime resulted in a formula that was used to correct the downward longwave radiation under clear skies. The correction is dependent on wind speed, in contrast to a recent paper showing negligible dependence, but is in accord with earlier findings. Based on manufacturer`s specifications, the pyranometer calibrations were considered to be within 2% of the World Radiation Reference. Thus a series of experiments was carried out using what were believed to be reasonably accurate component measurements of net radiation and measurements from the net pyrradiometer.

Duchon, C.L. [Univ. of Oklahoma, Norman, OK (United States); Wilk, G.E. [National Weather Service, Corpus Christi, TX (United States)

1994-02-01T23:59:59.000Z

429

Detection and diagnosis of faults and energy monitoring of HVAC systems with least-intrusive power analysis  

E-Print Network [OSTI]

Faults indicate degradation or sudden failure of equipment in a system. Widely existing in heating, ventilating, and air conditioning (HVAC) systems, faults always lead to inefficient energy consumption, undesirable indoor ...

Luo, Dong, 1966-

2001-01-01T23:59:59.000Z

430

Abstract-This paper investigates four different short circuit fault conditions which can occur for an inverter-fed perma-  

E-Print Network [OSTI]

for an inverter-fed perma- nent magnet synchronous motor (PMSM) with buried mag- nets. The fault conditions Condition #... Inverter PM machine (at steady state) N Short circuit fault conditions of a buried PMSM

Jantsch, Axel

431

Algorithms for Green Buildings: Learning-Based Techniques for Energy Prediction and Fault Diagnosis  

E-Print Network [OSTI]

Algorithms for Green Buildings: Learning-Based Techniques for Energy Prediction and Fault Diagnosis on servers or to redistribute to lists, requires prior specific permission. #12;Algorithms for Green Buildings: Learning-Based Techniques for Energy Prediction and Fault Diagnosis Daniel Holcomb Wenchao Li

Seshia, Sanjit A.

432

Treanmission Line Fault Location using Interoperability and Integration of Data and Model  

E-Print Network [OSTI]

. The second type is a sparse measurement based fault location scheme using phasor measurements from different substations located in the vicinity where the fault has occurred and can be applied if the measurements are not available from any of the line ends...

Dutta, Papiya

2014-01-10T23:59:59.000Z

433

Methodology for designing the fuzzy resolver for a radial distribution system fault locator  

E-Print Network [OSTI]

The Power System Automation Lab at Texas A&M University developed a fault location scheme that can be used for radial distribution systems. When a fault occurs, the scheme executes three stages. In the first stage, all data measurements and system...

Li, Jun

2006-04-12T23:59:59.000Z

434

Fault Tolerant Photodiode and Photogate Active Pixel Sensors , Glenn H. Chapmana  

E-Print Network [OSTI]

Fault Tolerant Photodiode and Photogate Active Pixel Sensors Cory Junga , Glenn H. Chapmana, this design can correct for most defects allowing for higher production yields. Fault tolerant photodiode and photogate APS' were fabricated in 0.18-micron technology. Testing showed that the photodiode APS could

Chapman, Glenn H.

435

FAULT DETECTION AND STATE EVALUATION OF ROTOR BLADES Yuri Petryna, Andreas Knzel, Matthias Kannenberg  

E-Print Network [OSTI]

FAULT DETECTION AND STATE EVALUATION OF ROTOR BLADES Yuri Petryna, Andreas Künzel, Matthias an approach for cost-effective, serial integrity tests of rotor blades. At that, manufacturing faults shall be automatically detected, localized and assessed with respect to their impact on the integrity of rotor blades

Boyer, Edmond

436

nD-RAPID: a multidimensional scalable fault-tolerant optoelectronic  

E-Print Network [OSTI]

nD-RAPID: a multidimensional scalable fault-tolerant optoelectronic interconnection for high of faults. We propose a multidimen- sional optoelectronic architecture, nD-RAPID (reconfigurable, and latency [4­7]. In this paper, we propose a novel optoelectronic architecture nD-RAPID (n Dimen- sional

Louri, Ahmed

437

A Smart Algorithm for the Diagnosis of Short-Circuit Faults in a Photovoltaic Generator  

E-Print Network [OSTI]

A Smart Algorithm for the Diagnosis of Short-Circuit Faults in a Photovoltaic Generator Wail Rezgui observations distributed over classes is used for simulation purposes. Keywords--Photovoltaic generator, SVM, k-NN, short-circuit fault, smart classification, linear programming. NOMENCLATURE PV = Photovoltaic; SVM

Paris-Sud XI, Université de

438

A Regression Algorithm for the Smart Prognosis of a Reversed Polarity Fault in a Photovoltaic Generator  

E-Print Network [OSTI]

A Regression Algorithm for the Smart Prognosis of a Reversed Polarity Fault in a Photovoltaic database containing sample data is used for simulation purposes. Keywords--Photovoltaic generator, SVR, k-NNR, reversed polarity fault, diagnosis, prognosis. NOMENCLATURE PV = Photovoltaic; SVM = Support Vector

Paris-Sud XI, Université de

439

Voltage grid support of DFIG wind turbines during grid faults Anca D. Hansen1  

E-Print Network [OSTI]

Voltage grid support of DFIG wind turbines during grid faults Anca D. Hansen1 , Gabriele Michalke2) wind turbines address primarily the design of DFIG wind turbine control with special focus on power strategy for DFIG wind turbines, which enhances the fault ride-through capability of DFIG wind turbines

440

PWM Inverter-Fed Induction Motor-Based Electrical Vehicles Fault-Tolerant Control  

E-Print Network [OSTI]

PWM Inverter-Fed Induction Motor-Based Electrical Vehicles Fault-Tolerant Control Bekheïra Tabbache proposes a fault-tolerant control scheme for PWM inverter-fed induction motor-based electric vehicles and simulations on an electric vehicle are carried-out using a European urban driving cycle to assess the FTC

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Fault detection and isolation in aircraft gas turbine engines. Part 1: underlying concept  

E-Print Network [OSTI]

307 Fault detection and isolation in aircraft gas turbine engines. Part 1: underlying concept: aircraft propulsion, gas turbine engines, fault detection and isolation, statistical pattern recognition 1 INTRODUCTION Performance and reliability of aircraft gas turbine engines gradually deteriorate over the service

Ray, Asok

442

Detecting Intrusion Faults in Remotely Controlled Systems Salvatore Candido and Seth Hutchinson  

E-Print Network [OSTI]

the design process. With this in mind, researchers have begun to address security issues specific to controlDetecting Intrusion Faults in Remotely Controlled Systems Salvatore Candido and Seth Hutchinson to a remote-controlled system (deemed an "intrusion fault" or "intrusion") despite attempts to conceal

Hutchinson, Seth

443

Exact Computation of Maximally Dominating Faults and Its Application to -Detection Tests  

E-Print Network [OSTI]

Exact Computation of Maximally Dominating Faults and Its Application to -Detection Tests Ilia, IN 47907, USA Abstract £ -detection test sets for stuck-at faults have been shown to be useful in detecting an important role in controlling the increase in the size of an £ -detection test set as £ is increased

Polian, Ilia

444

Automated Analysis of Fault-Tolerance in Distributed Systems Scott D. Stoller y  

E-Print Network [OSTI]

Automated Analysis of Fault-Tolerance in Distributed Systems #3; Scott D. Stoller y Computer satisfy in speci#12;ed failure scenarios. Our analysis method is to compute, for each failure scenario for which the user speci#12;ed a fault-tolerance requirement, an MFG representing the system's communication

Schneider, Fred B.

445

Robust Codes for Fault Attack Resistant Cryptographic Konrad J. Kulikowski, Mark G. Karpovsky, Alexander Taubin  

E-Print Network [OSTI]

Robust Codes for Fault Attack Resistant Cryptographic Hardware Konrad J. Kulikowski, Mark G algorithms are vulner- able to fault analysis attacks. To detect these attacks we propose an architec- ture by an attacker. Architectures based on these codes have fewer undetectable er- rors than linear codes

Karpovsky, Mark

446

A Probability Extension of PCA to Detect and Diagnose Sensor Faults in Air Handling Units  

E-Print Network [OSTI]

Due to sensor faults, it is a challenge to successfully detect and diagnose component faults in HVAC systems. The Principal Component Analysis (PCA) method has become a popular method to tackle this problem in recent years, but PCA is not capable...

Li, Z.

2011-01-01T23:59:59.000Z

447

Christiaan J.J. Paredis and Pradeep K. Khosla, ``Designing Fault Tolerant Manipulators: How Many Degreesoffreedom?''  

E-Print Network [OSTI]

Degrees­of­freedom?'' to appear in The International Journal of Robotics Research, 1996. Designing Fault design templates for spatial fault tolerant manipulators. In a second approach, both the Cartesian task in their robot designs (Wu et al. 1993). Reliability is also #12; 2 Christiaan J.J. Paredis and Pradeep K. Khosla

448

Action Models: A Reliability Modeling Formalism for Fault-Tolerant Distributed Computing Systems  

E-Print Network [OSTI]

Action Models: A Reliability Modeling Formalism for Fault-Tolerant Distributed Computing Systems. Introduction Model-based evaluation of the reliability of distributed systems has traditionally required expert- proach to analyze the reliability of fault-tolerant distributed systems. More in particular, we want

Newcastle upon Tyne, University of

449

Can Fault Prediction Models and Metrics be Used for Vulnerability Prediction? Yonghee Shin and Laurie Williams  

E-Print Network [OSTI]

Can Fault Prediction Models and Metrics be Used for Vulnerability Prediction? Yonghee Shin to prioritize security inspection and testing efforts may be better served by a prediction model that indicates commonalities that may allow development teams to use traditional fault prediction models and metrics

Young, R. Michael

450

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1  

E-Print Network [OSTI]

Modeling and Measurement Constraints in Fault Diagnostics for HVAC Systems Massieh Najafi1 , David for determining HVAC diagnostics, methods to detect faults in HVAC systems are still generally undeveloped. Most in a substantial increase in energy use. For example, failure of an HVAC fan may prevent cool air from one

451

First-principles calculations of twin-boundary and stacking-fault energies in magnesium  

E-Print Network [OSTI]

First-principles calculations of twin-boundary and stacking-fault energies in magnesium Y. Wang and stacking faults in metal magnesium have been calculated using first-principles supercell approach. Four. Keywords: Magnesium; Interfaces; Twinning; First-principles calculation Magnesium alloys are increasingly

Chen, Long-Qing

452

Shallow seismic reflection profile of the Meers fault, Comanche County, Oklahoma  

E-Print Network [OSTI]

.J., The Meers fault tectonic activity in south- western Oklahoma, U. S. Nuclear Regulatory Commission, NUREG ICR-4852, 1-25, A1-A25, 1987. McLean, R., and Stearns, D.W., Fault analysis in the Wichita Mountains [Abs. ], AAPG Bull. 67, 511-512, 1983. Miller...

Myers, Paul B.; Miller, Richard D.; Steeples, Don W.

1987-07-01T23:59:59.000Z

453

DFIG Driven Wind Turbine Grid Fault-Tolerance Using High-Order Sliding Mode Control  

E-Print Network [OSTI]

DFIG Driven Wind Turbine Grid Fault-Tolerance Using High-Order Sliding Mode Control Mohamed fault-tolerance of a doubly-fed induction generator- based wind turbine using high-order sliding mode mechanical stress on the drive train). Simulations using the NREL FAST code on a 1.5-MW wind turbine

Boyer, Edmond

454

Morphology, displacement, and slip rates along the North Anatolian Fault, Turkey  

E-Print Network [OSTI]

Morphology, displacement, and slip rates along the North Anatolian Fault, Turkey Aure´lia Hubert, Ayazaga, Istanbul, Turkey Received 29 January 2001; revised 8 January 2002; accepted 13 January 2002 the central and eastern North Anatolian Fault (NAF) in Turkey. The NAF total displacement is reevaluated using

Hubert-Ferrari, Aurélia

455

Miocene faulting at plate tectonic velocity in the Himalaya of central Nepal  

E-Print Network [OSTI]

Miocene faulting at plate tectonic velocity in the Himalaya of central Nepal Matthew J. Kohna, Tri-Chandra Campus, Ghantaghar, Kathmandu, Nepal, United States Received 7 April 2004; received (MCT) and affiliated faults in central Nepal. Inferred rates were 1.5F0.9 cm/yr (Langtang Thrust, ~19

456

Off-fault plasticity and earthquake rupture dynamics: 2. Effects of fluid saturation  

E-Print Network [OSTI]

Off-fault plasticity and earthquake rupture dynamics: 2. Effects of fluid saturation Robert C slip-weakening behavior is specified, and the off-fault material is described using an elastic-plastic poroelastoplastic materials with and without plastic dilation. During nondilatant undrained response near

457

Modeling and simulation of a reformate supplied PEM fuel cell stack, application to fault detection  

E-Print Network [OSTI]

Modeling and simulation of a reformate supplied PEM fuel cell stack, application to fault detection exchange membrane (PEM) fuel cells are the main type of fuel cell developed for ground vehicle applications tool for thermal characteristic and fault detection of a PEM fuel cell stack. The fuel cell stack model

Paris-Sud XI, Université de

458

A 2D Pseudodynamic Rupture Model Generator for Earthquakes on Geometrically Complex Faults  

E-Print Network [OSTI]

A 2D Pseudodynamic Rupture Model Generator for Earthquakes on Geometrically Complex Faults complexity in the rupture process and resulting ground motion. We present a 2D kinematic rupture generator that emulates the strong dependence of earthquake source parameters on local fault geometry observed in dynamic

Dunham, Eric M.

459

Establishment of the mathematical model for diagnosing the engine valve faults by genetic  

E-Print Network [OSTI]

in a six- cylinders/four-stroke cycle diesel engine, i.e. normal condition, valve-tappet clearance and gas for diagnosing the faults occurring in rotor-bearing system, but current computer programs cannot easily distinguish the orbit shapes automatically. Likewise, when diagnosing the faults in a rolling-element bearing

Fernandez, Thomas

460

System for detecting and limiting electrical ground faults within electrical devices  

DOE Patents [OSTI]

An electrical ground fault detection and limitation system for employment with a nuclear reactor utilizing a liquid metal coolant. Elongate electromagnetic pumps submerged within the liquid metal coolant and electrical support equipment experiencing an insulation breakdown occasion the development of electrical ground fault current. Without some form of detection and control, these currents may build to damaging power levels to expose the pump drive components to liquid metal coolant such as sodium with resultant undesirable secondary effects. Such electrical ground fault currents are detected and controlled through the employment of an isolated power input to the pumps and with the use of a ground fault control conductor providing a direct return path from the affected components to the power source. By incorporating a resistance arrangement with the ground fault control conductor, the amount of fault current permitted to flow may be regulated to the extent that the reactor may remain in operation until maintenance may be performed, notwithstanding the existence of the fault. Monitors such as synchronous demodulators may be employed to identify and evaluate fault currents for each phase of a polyphase power, and control input to the submerged pump and associated support equipment.

Gaubatz, Donald C. (Cupertino, CA)

1990-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Online Model-based Diagnosis for Multiple, Intermittent and Interaction Faults  

E-Print Network [OSTI]

convert, move and process materials or objects. Examples of such systems are printers, refineries. An interaction fault is present if a set of components operating on the same object, damage the object even though each component alone produces non noticeable damage. Introducing interaction faults is much

de Kleer, Johan

462

Fault Evolution in Photovoltaic Array During Night-to-Day Transition  

E-Print Network [OSTI]

amount of energy loss. For example, in UK domestic PV systems, the annual energy loss due to faults in PV Fault detection and protection in solar photovoltaic (PV) arrays are important tasks for improving PV at night when there is no solar irradiance. During sunrise, the irradiance on the PV array increases slowly

Lehman, Brad

463

A nested invocation suppression mechanism for active replication fault-tolerant CORBA  

E-Print Network [OSTI]

1 A nested invocation suppression mechanism for active replication fault-tolerant CORBA Deron Liang. The redundant nested invocation (RNI) problem arises when servers in a replicated group issues nested a mechanism to perform auto-suppression of redundant nested invocation in an active replication fault

Chen, Sheng-Wei

464

A Fully Automated Fault-tolerant System for Distributed Video Processing and Off-site Replication  

E-Print Network [OSTI]

A Fully Automated Fault-tolerant System for Distributed Video Processing and Off-site Replication been a failure-prone tedious operation with an operator needed to babysit the processing and off-site, off-site replication, fault-tolerance, grid, educational research. 1. INTRODUCTION In different fields

Wisconsin at Madison, University of

465

Hydrogeological aspects of fault zones on various scales in the Roer Valley Rift System  

E-Print Network [OSTI]

for an estimate of the micro-scale variation of the hydraulic properties within a fault zone. Additional core on several scales show a variety of hydro- geological aspects of faults. 2. Examples 2.1. The hydraulic can be studied on micro-scal

Bense, Victor

466

Real-time fault detection and isolation in biological wastewater treatment plants  

E-Print Network [OSTI]

Real-time fault detection and isolation in biological wastewater treatment plants F. Baggiani and S@dsi.unifi.it Automatic fault detection is becoming increasingly important in wastewater treatment plant operation, given automation controllers, wastewater treatment INTRODUCTION Real-time monitoring is an increasingly important

467

An On-line Method for Stator Fault Detection in Multi-phase PMSM Drives  

E-Print Network [OSTI]

An On-line Method for Stator Fault Detection in Multi-phase PMSM Drives Fabien Meinguet*, Eric deals with an on-line fault detection method for multi-phase PMSM drives. The method is based an original method for detecting an abnormal asymmetrical behavior in five-phase PMSM drives and we apply

Paris-Sud XI, Université de

468

Oil and Gas CDT Predicting fault permeability at depth: incorporating natural  

E-Print Network [OSTI]

Oil and Gas CDT Predicting fault permeability at depth: incorporating natural permeability controls on fluid flow in oil and gas reservoirs. Fault zones are composed of many deformation elements will receive 20 weeks bespoke, residential training of broad relevance to the oil and gas industry: 10 weeks

Henderson, Gideon

469

Bayesian network for the characterization of faults in a multivariate process  

E-Print Network [OSTI]

Bayesian network for the characterization of faults in a multivariate process Sylvain VERRON of multivariate processes, we propose an original network structure allowing deciding if a fault is appeared in the process. More, this structure permits the identification of the variables that are responsible (root

Paris-Sud XI, Université de

470

Fault-tolerant Holonomic Quantum Computation in Surface Codes  

E-Print Network [OSTI]

We show that universal holonomic quantum computation (HQC) can be achieved fault-tolerantly by adiabatically deforming the gapped stabilizer Hamiltonian of the surface code, where quantum information is encoded in the degenerate ground space of the system Hamiltonian. We explicitly propose procedures to perform each logical operation, including logical state initialization, logical state measurement, logical CNOT, state injection and distillation,etc. In particular, adiabatic braiding of different types of holes on the surface leads to a topologically protected, non-Abelian geometric logical CNOT. Throughout the computation, quantum information is protected from both small perturbations and low weight thermal excitations by a constant energy gap, and is independent of the system size. Also the Hamiltonian terms have weight at most four during the whole process. The effect of thermal error propagation is considered during the adiabatic code deformation. With the help of active error correction, this scheme is fault-tolerant, in the sense that the computation time can be arbitrarily long for large enough lattice size. It is shown that the frequency of error correction and the physical resources needed can be greatly reduced by the constant energy gap.

Yi-Cong Zheng; Todd A. Brun

2015-02-04T23:59:59.000Z

471

Fault current limiter and alternating current circuit breaker  

DOE Patents [OSTI]

A solid-state circuit breaker and current limiter are disclosed for a load served by an alternating current source having a source impedance, the solid-state circuit breaker and current limiter comprising a thyristor bridge interposed between the alternating current source and the load, the thyristor bridge having four thyristor legs and four nodes, with a first node connected to the alternating current source, and a second node connected to the load. A coil is connected from a third node to a fourth node, the coil having an impedance of a value calculated to limit the current flowing therethrough to a predetermined value. Control means are connected to the thyristor legs for limiting the alternating current flow to the load under fault conditions to a predetermined level, and for gating the thyristor bridge under fault conditions to quickly reduce alternating current flowing therethrough to zero and thereafter to maintain the thyristor bridge in an electrically open condition preventing the alternating current from flowing therethrough for a predetermined period of time. 9 figs.

Boenig, H.J.

1998-03-10T23:59:59.000Z

472

100 Area electrical distribution fault and coordination report  

SciTech Connect (OSTI)

This report documents three-phase and line-to-ground fault values and time overcurrent coordination curves for the electrical utility distribution system located in the 100 Areas. Activities that may improve the coordination of the distribution system have also been identified. An evaluation of system coordination was performed. The results of this evaluation are listed in Appendix B. There are protective devices within the 100 Area distribution system that do not coordinate with one another throughout the Areas. There is also a mis-application of reclosing relays at the 100B Area. The impact of the mis-coordination and incorrect application of reclosing relays is that system selectivity is reduced. Equipment will still be protected against damaging currents, however more equipment will be de-energized than necessary during fault conditions. It is the opinion of the author of this report that the cases of mis-coordination listed above, and in Appendix B, do not significantly degrade the system protection system nor the reliability of the 100 Area distribution system. Therefore, immediate response to correct these problems is not recommended. However, a planned methodology, outlined in an Activity Plan, to correct these problems should be developed and implemented in the near future.

Webber, J.J. [ICF Kaiser Hanford Co., Richland, WA (United States)

1994-09-23T23:59:59.000Z

473

A core-based assessment of the spatial relationship of small faults associated with a basement-controlled, large normal fault in the Hickory Sandstone  

E-Print Network [OSTI]

with reverse-slip, showing associated fault strike, dip polarity and cumulative displacement per foot????????????????????? Page 79 80 81 82 83 84 85 86 87 88 89 xii FIGURE 52 Borehole NNR-8: Distribution of small faults with reverse... they were purged from the ?density? measures???.. 3 Descriptive statistics for sample data (n = 692) of displacement, gouge thickness and corresponding log transforms????????????. 4 Summary statistics for ln displacement of all four grain sizes for a...

Graff, Mitchell C

2006-10-30T23:59:59.000Z

474

Identification of critical stacking faults in thin-film CdTe solar cells  

SciTech Connect (OSTI)

Cadmium telluride (CdTe) is a p-type semiconductor used in thin-film solar cells. To achieve high light-to-electricity conversion, annealing in the presence of CdCl{sub 2} is essential, but the underlying mechanism is still under debate. Recent evidence suggests that a reduction in the high density of stacking faults in the CdTe grains is a key process that occurs during the chemical treatment. A range of stacking faults, including intrinsic, extrinsic, and twin boundary, are computationally investigated to identify the extended defects that limit performance. The low-energy faults are found to be electrically benign, while a number of higher energy faults, consistent with atomic-resolution micrographs, are predicted to be hole traps with fluctuations in the local electrostatic potential. It is expected that stacking faults will also be important for other thin-film photovoltaic technologies.

Yoo, Su-Hyun; Walsh, Aron, E-mail: a.walsh@bath.ac.uk [Global E3 Institute, Department of Materials Science and Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Centre for Sustainable Chemical Technologies and Department of Chemistry, University of Bath, Bath BA2 7AY (United Kingdom); Butler, Keith T. [Centre for Sustainable Chemical Technologies and Department of Chemistry, University of Bath, Bath BA2 7AY (United Kingdom); Soon, Aloysius [Global E3 Institute, Department of Materials Science and Engineering, Yonsei University, Seoul 120-749 (Korea, Republic of); Abbas, Ali; Walls, John M., E-mail: j.m.wall@loughborough.ac.uk [Centre for Renewable Energy Systems Technology, School of Electronic, Electrical and Systems Engineering, Loughborough University, Leicestershire LE11 3TU (United Kingdom)

2014-08-11T23:59:59.000Z

475

System and method for motor fault detection using stator current noise cancellation  

DOE Patents [OSTI]

A system and method for detecting incipient mechanical motor faults by way of current noise cancellation is disclosed. The system includes a controller configured to detect indicia of incipient mechanical motor faults. The controller further includes a processor programmed to receive a baseline set of current data from an operating motor and define a noise component in the baseline set of current data. The processor is also programmed to acquire at least on additional set of real-time operating current data from the motor during operation, redefine the noise component present in each additional set of real-time operating current data, and remove the noise component from the operating current data in real-time to isolate any fault components present in the operating current data. The processor is then programmed to generate a fault index for the operating current data based on any isolated fault components.

Zhou, Wei (Los Angeles, CA); Lu, Bin (Kenosha, WI); Nowak, Michael P. (Menomonee Falls, WI); Dimino, Steven A. (Wauwatosa, WI)

2010-12-07T23:59:59.000Z

476

System and method for bearing fault detection using stator current noise cancellation  

DOE Patents [OSTI]

A system and method for detecting incipient mechanical motor faults by way of current noise cancellation is disclosed. The system includes a controller configured to detect indicia of incipient mechanical motor faults. The controller further includes a processor programmed to receive a baseline set of current data from an operating motor and define a noise component in the baseline set of current data. The processor is also programmed to repeatedly receive real-time operating current data from the operating motor and remove the noise component from the operating current data in real-time to isolate any fault components present in the operating current data. The processor is then programmed to generate a fault index for the operating current data based on any isolated fault components.

Zhou, Wei (Los Angeles, CA); Lu, Bin (Kenosha, WI); Habetler, Thomas G. (Snellville, GA); Harley, Ronald G. (Lawrenceville, GA); Theisen, Peter J. (West Bend, WI)

2010-08-17T23:59:59.000Z

477

Fault tree synthesis for software design analysis of PLC based safety-critical systems  

SciTech Connect (OSTI)

As a software verification and validation should be performed for the development of PLC based safety-critical systems, a software safety analysis is also considered in line with entire software life cycle. In this paper, we propose a technique of software safety analysis in the design phase. Among various software hazard analysis techniques, fault tree analysis is most widely used for the safety analysis of nuclear power plant systems. Fault tree analysis also has the most intuitive notation and makes both qualitative and quantitative analyses possible. To analyze the design phase more effectively, we propose a technique of fault tree synthesis, along with a universal fault tree template for the architecture modules of nuclear software. Consequently, we can analyze the safety of software on the basis of fault tree synthesis. (authors)

Koo, S. R.; Cho, C. H. [Corporate R and D Inst., Doosan Heavy Industries and Construction Co., Ltd., 39-3, Seongbok-Dong, Yongin-Si, Gyeonggi-Do 449-795 (Korea, Republic of); Seong, P. H. [Dept. of Nuclear and Quantum Engineering, Korea Advanced Inst. of Science and Technology, 373-3 Guseong-dong, Yuseong-gu, Daejeon, 305-701 (Korea, Republic of)

2006-07-01T23:59:59.000Z

478

Feasibility and electromagnetic compatibility study of the ClearPEM front-end electronics for simultaneous PET-MR imaging  

E-Print Network [OSTI]

electromagnetic interference (EMI) effects between both systems were evaluated on a 7 T magnet by characterizing. Materials and methods The mutual electromagnetic interference tests between Clear- PEM front-end electronics

Dalang, Robert C.

479

Assessment of clear and cloudy sky parameterizations for daily downwelling longwave radiation over different land surfaces in  

E-Print Network [OSTI]

meteorological data, resulting in reliable quantification of net radiation and evapotranspiration in FloridaAssessment of clear and cloudy sky parameterizations for daily downwelling longwave radiation over sky downwelling longwave radiation (Rldc) and cloudy sky downwelling longwave radiation (Rld) formulas

480

Influences of recovery from clear-cut, climate variability, and thinning on the carbon balance of a young  

E-Print Network [OSTI]

Influences of recovery from clear-cut, climate variability, and thinning on the carbon balance secondary effects www.elsevier.com/locate/agrformet Agricultural and Forest Meteorology 130 (2005) 207

Cohen, Ronald C.

Note: This page contains sample records for the topic "delayed fault clearing" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Yes, I would like to sign up for Finance Committee on: _____/_____/2014 (Please print clearly and legibly)  

E-Print Network [OSTI]

Yes, I would like to sign up for Finance Committee on: _____/_____/2014 (Please print clearly Name from AICA Leadership/Advisor Yes, I would like to sign up for Finance Committee on

de Lijser, Peter

482

Sensor Fault-Tolerant Control of an Induction Motor Based Electric Vehicle Bekhera Tabbache1,2  

E-Print Network [OSTI]

Sensor Fault-Tolerant Control of an Induction Motor Based Electric Vehicle Bekheïra Tabbache1://www.lbms.fr Keywords Electric Vehicle (EV), Induction motor, Sensor fault, Fault-tolerant control (FTC), Direct torque a reconfigurable direct torque control of an induction motor-based electric vehicle. The proposed strategy concerns

Paris-Sud XI, Université de

483

Earthquake Rupture at Focal Depth, Part I: Structure and Rupture of the Pretorius Fault, TauTona Mine, South Africa  

E-Print Network [OSTI]

Tona Mine, South Africa V. HEESAKKERS,1,2 S. MURPHY,1,3 and Z. RECHES 1 Abstract--We analyze the structure of the Archaean Pretorius fault in TauTona mine, South Africa, as well as the rupture-zone that recently, South Africa 2011, this volume). Key words: Brittle faulting, fault reactivation, earthquake mechanics

Ze'ev, Reches

484

Proceedings of the 2008 International Conference on Electrical Machines Paper ID 1434 DFIG-Based Wind Turbine Fault Diagnosis  

E-Print Network [OSTI]

-Based Wind Turbine Fault Diagnosis Using a Specific Discrete Wavelet Transform E. Al-Ahmar1,2 , M for electrical and mechanical fault diagnosis in a DFIG-based wind turbine. The investigated technique unambiguously diagnose faults under transient conditions. Index Terms--Wind turbine, Doubly-Fed Induction

Boyer, Edmond

485

Simulation of a flexible wind turbine response to a grid fault Anca D. Hansen*, Nicolaos A. Cutululis*, Poul Srensen*,  

E-Print Network [OSTI]

Simulation of a flexible wind turbine response to a grid fault Anca D. Hansen*, Nicolaos A of a wind turbine. Grid faults generate transients in the generator electromagnetic torque, which are propagated in the wind turbine, stressing its mechanical components. Grid faults are normally simulated

486

Interseismic deformation and creep along the central section of the North Anatolian Fault (Turkey): InSAR observations  

E-Print Network [OSTI]

Interseismic deformation and creep along the central section of the North Anatolian Fault (Turkey the central section of the North Anatolian Fault (NAF) in Turkey using interferometric synthetic aperture along the central section of the North Anatolian Fault (Turkey): InSAR observations and implications

Fialko, Yuri

487

Interseismic deformation and creep along the central section of the North Anatolian Fault (Turkey): InSAR observations  

E-Print Network [OSTI]

Interseismic deformation and creep along the central section of the North Anatolian Fault (Turkey Anatolian Fault (NAF) in Turkey using interferometric synthetic aperture radar data from the Advanced Land Anatolian Fault (Turkey): InSAR observations and implications for rate-and-state friction properties, J

Sandwell, David T.

488

Off-fault plasticity and earthquake rupture dynamics: 1. Dry materials or neglect of fluid pressure changes  

E-Print Network [OSTI]

Off-fault plasticity and earthquake rupture dynamics: 1. Dry materials or neglect of fluid pressure an explicit dynamic finite element procedure. A Mohr-Coulomb type elastic-plastic description describes-fault plasticity during dynamic rupture. Those include the angle with the fault of the maximum compressive

489

Scheduling algorithms for throughput maximization in time-varying networks with reconfiguration delays  

E-Print Network [OSTI]

We consider the control of possibly time-varying wireless networks under reconfiguration delays. Reconfiguration delay is the time it takes to switch network resources from one subset of nodes to another and it is a ...

Celik, Guner Dincer

2012-01-01T23:59:59.000Z

490

- and -delayed neutron- decay of neutron-rich copper isotopes  

SciTech Connect (OSTI)

The {beta}-decay properties of neutron-rich Cu isotopes produced in proton-induced fission of {sup 238}U were studied at the Holifield Radioactive Ion Beam Facility at Oak Ridge National Laboratory. The data were collected using high-resolution online mass separation, reacceleration, and digital {beta}-{gamma} spectroscopy methods. An improved decay scheme of N = 49 {sup 78}Cu and the first observation of N = 50 {sup 79}Cu {beta}-delayed neutron decay followed by a gamma transition are reported. Spin and parity (5{sup -}) are deduced for {sup 78gs}Cu. The {beta}-delayed neutron branching ratios (P{sub {beta}n}) for the {sup 77}Cu and {sup 79}Cu precursors are analyzed with the help of nuclear structure models.

Korgul, A. [University of Warsaw; Rykaczewski, Krzysztof Piotr [ORNL; Winger, J. A. [Oak Ridge Associated Universities (ORAU); Ilyushkin, S. [Mississippi State University (MSU); Gross, Carl J [ORNL; Batchelder, J. C. [Oak Ridge Associated Universities (ORAU); Bingham, C. R. [University of Tennessee, Knoxville (UTK); Borzov, Ivan N [ORNL; Goodin, C. [Vanderbilt University; Grzywacz, Robert Kazimierz [ORNL; Hamilton, Joseph H [ORNL; Krolas, W. [Joint Institute for Heavy Ion Research, Oak Ridge; Liddick, S. N. [Oak Ridge Associated Universities (ORAU); Mazzocchi, C. [University of Warsaw; Nelson, C. [Vanderbilt University; Nowacki, F. [Institut Pluridisciplinaire Hubert Curien, Strasbourg, France; Padgett, Stephen [University of Tennessee, Knoxville (UTK); Piechaczek, A. [Louisiana State University; Rajabali, M. M. [University of Tennessee, Knoxville (UTK); Shapira, Dan [ORNL; Sieja, K. [Technische Universitat Darmstadt, Germany; Zganjar, E. F. [Louisiana State University

2012-01-01T23:59:59.000Z

491

How to induce multiple delays in coupled chaotic oscillators?  

SciTech Connect (OSTI)

Lag synchronization is a basic phenomenon in mismatched coupled systems, delay coupled systems, and time-delayed systems. It is characterized by a lag configuration that identifies a unique time shift between all pairs of similar state variables of the coupled systems. In this report, an attempt is made how to induce multiple lag configurations in coupled systems when different pairs of state variables attain different time shift. A design of coupling is presented to realize this multiple lag synchronization. Numerical illustration is given using examples of the Rössler system and the slow-fast Hindmarsh-Rose neuron model. The multiple lag scenario is physically realized in an electronic circuit of two Sprott systems.

Bhowmick, Sourav K. [CSIR-Indian Institute of Chemical Biology, Jadavpur, Kolkata 700032 (India) [CSIR-Indian Institute of Chemical Biology, Jadavpur, Kolkata 700032 (India); Department of Electronics, Asutosh College, Kolkata 700026 (India); Ghosh, Dibakar [Physics and Applied Mathematics Unit, Indian Statistical Institute, Kolkata 700108 (India)] [Physics and Applied Mathematics Unit, Indian Statistical Institute, Kolkata 700108 (India); Roy, Prodyot K. [Department of Physics, Presidency University, Kolkata 700073 (India)] [Department of Physics, Presidency University, Kolkata 700073 (India); Kurths, Jürgen [Potsdam Institute for Climate Impact Research, 14473 Potsdam (Germany) [Potsdam Institute for Climate Impact Research, 14473 Potsdam (Germany); Institute for Physics, Humboldt University, 12489 Berlin (Germany); Dana, Syamal K. [CSIR-Indian Institute of Chemical Biology, Jadavpur, Kolkata 700032 (India)] [CSIR-Indian Institute of Chemical Biology, Jadavpur, Kolkata 700032 (India)

2013-12-15T23:59:59.000Z

492

Robust chaos in autonomous time-delay system  

E-Print Network [OSTI]

We consider an autonomous system constructed as modification of the logistic differential equation with delay that generates successive trains of oscillations with phases evolving according to chaotic maps. The system contains two feedback loops characterized by two generally distinct retarding time parameters. In the case of their equality, chaotic dynamics is associated with the Smale-Williams attractor that corresponds to the double-expanding circle map for the phases of the carrier of the oscillatory trains. Alternatively, at appropriately chosen two different delays attractor is close to torus with Anosov dynamics on it as the phases are governed by the Fibonacci map. In both cases the attractors manifest robustness (absence of regularity windows under variation of parameters) and presumably relate to the class of structurally stable hyperbolic attractors.

D. S. Arzhanukhina; S. P. Kuznetsov

2014-04-16T23:59:59.000Z

493

Maximum and minimum sensitizable timing analysis using data dependent delays  

E-Print Network [OSTI]

NAND gate that cause its output to switch Rising Transition # ab ! ab Delay(ps) 1 11 ! 00 30.5 2 11 ! 01 50.5 3 11 ! 10 53.0 Falling Transition # ab ! ab Delay(ps) 1 00 ! 11 55.3 2 01 ! 11 46.5 3 10 ! 11 42.7 Output FallingOutput Rising 30.5 42.7 46... effectively goes through the tran- sition 11 ! 01 ! 00 rather than 11 ! 00 directly. Note that the output of the NAND2 gate 13 10ps 35ps 60.5ps 30.5ps 50.5ps 55.3ps 42.7ps 10ps 35ps 77.7ps b) Rising Output a) Falling Output b a c b a c a b c Fig. II.3. Example...

Singh, Karandeep

2007-09-17T23:59:59.000Z

494

Quantitative studies of severe fuel damage using delayed neutron data  

SciTech Connect (OSTI)

A technique to quantify fuel damage in an LMR through analysis of delayed neutron data is presented, which is suitable for analysis of both small-scale in-pile experiments and full-scale plants. Validating analyses are described for five in-pile severe accident simulations performed within the SLSF and Mol 7C test programs. Comparison is made of measured and calculated amounts of fuel damage. 8 refs., 5 figs., 2 tabs.

Bauer, T.H.; Braid, T.H. (Argonne National Lab., IL (USA)); Schleisiek, K. (Kernforschungszentrum Karlsruhe GmbH (Germany, F.R.))

1990-01-01T23:59:59.000Z

495

{beta}-delayed neutron decay of {sup 14}Be  

SciTech Connect (OSTI)

The neutron spectroscopy of the {beta}-delayed neutron decay of {sup 14}Be has been investigated. Two neutron groups were observed, and energy limits are given for a third (unobserved) group that receives most of the {beta}-decay strength. Branching ratios and log{ital ft} values deduced for all three groups are compared with the results of a shell-model calculation.

Belbot, M.D.; Kolata, J.J.; Lamkin, K.; Tighe, R.J.; Zahar, M. [Physics Department, University of Notre Dame, Notre Dame, Indiana 46556 (United States)] [Physics Department, University of Notre Dame, Notre Dame, Indiana 46556 (United States); Harkewicz, R.; Morrissey, D.J.; Orr, N.A.; Ronningen, R.M.; Sherrill, B.M.; Winger, J.A. [Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States)] [Cyclotron Laboratory, Michigan State University, East Lansing, Michigan 48824 (United States); Carpenter, M. [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States)] [Physics Division, Argonne National Laboratory, Argonne, Illinois 60439 (United States)

1995-05-01T23:59:59.000Z

496

Quantitative studies of severe fuel damage using delayed neutron data  

SciTech Connect (OSTI)

In this paper, a technique is presented to quantify fuel damage in a liquid-metal reactor through fast-running computer analysis of delayed neutron data, suitable for analysis of both small-scale in-pile experiments and full-scale plants. Validating analyses are described for five in-pile severe accident simulations performed within the Sodium Loop Safety Facility and Mol-7C test programs. Comparison is made of measured and calculated amounts of fuel damage.

Bauer, T.H.; Braiel, T.H. (Argonne National Lab., IL (United States)); Schleisiek, K. (Kernforschungszentrum Karlsruhe GmbH (Germany))

1992-09-01T23:59:59.000Z

497

Monte Carlo Modeling of Delayed Neutrons from Photofission  

SciTech Connect (OSTI)

We describe the implementation of algorithms related to the delayed neutron production in photon-induced fission on actinides. The algorithms are based on data from experiments and have been implemented in the MCNP-PoliMi code. The modified code is being used to design and analyze methods to identify concealed highly enriched uranium with a system based on the use of photon interrogation and scintillation detectors.

Pozzi, Sara A [ORNL; Monville, Maura E [ORNL; Padovani, Enrico [Nuclear Engineering Department Politecnico di Milano, Milan, Italy

2007-01-01T23:59:59.000Z

498

Light deflection and time delay in the solar gravitational field  

SciTech Connect (OSTI)

The second nonvanishing order of contribution to light deflection and time delay in the solar gravitational field is studied for a realistic solar model and for a wide range of metric theories of gravity. It is shown that the second-order effects arise at order (GM/c/sup 2/R)/sup 2/ identical to epsilon/sup 4/. To calculate these effects, every component of the solar metric must be known to order epsilon/sup 4/. The parametrized post-Newtonian (PPN) metric provides most of those components. However, some extension of the PPN metric is required. This extension leads to the parametrized post-linear (PPL) metric, which is used in all calculations. To study light deflection to order epsilon/sup 4/ requires that the orbits of scattered photons be known to that order. These orbits are solved for, first in the equatorial plane and then in general, and are used to determine the deflection as measured by an observer at rest with respect to the sun. In the equatorial plane there is only a radial component to this deflection. In general, there is another component orthogonal to the radial plane, but knowledge of this component is not necessary to determine the total deflection to order epsilon/sup 4/. The total second-order deflection can be as large as 300..mu.. arcsec (for deflection by Jupiter). Measurements of some second-order terms are within the astrometric capabilities of experiments proposed for the 1990's. The time delay in the round-trip travel time of a radar beam reflected from a planet is due to the variable coordinate speed of the light signal and to the bending of the beam path. The delay is calculated to order epsilon/sup 4/. It is shown that the beam-bending gives a second-order contribution as large as the present-day uncertainties in time delay experiments with the Viking spacecraft.

Richter, G.W.

1983-01-01T23:59:59.000Z

499

Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells  

DOE Patents [OSTI]

Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl[sub 2] and SO[sub 2]Cl[sub 2] electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl[sub 2] and Li/SO[sub 2]Cl[sub 2] batteries.

Delnick, F.M.

1993-04-13T23:59:59.000Z

500

Chloromethyl chlorosulfate as a voltage delay inhibitor in lithium cells  

DOE Patents [OSTI]

Chloromethyl chlorosulfate (CMCS) is used as a passive film growth inhibitor in electrochemical cells to minimize voltage delay and low-voltage discharge. Film growth on lithium anodes is significantly diminished when CMCS is added to SOCl.sub.2 and SO.sub.2 Cl.sub.2 electrolytes of lithium batteries. The CMCS also has the effect of extending the shelf-life of Li/SOCl.sub.2 and Li/SO.sub.2 Cl.sub.2 batteries.

Delnick, Frank M. (Albuquerque, NM)

1993-01-01T23:59:59.000Z