Powered by Deep Web Technologies
Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

^ ^ Cambridge Technology, Inc. -= 109 Smith Place, Cambridge, MA 02138  

E-Print Network (OSTI)

^ ^ Cambridge Technology, Inc. - = 109 Smith Place, Cambridge, MA 02138 Tel: 617-441-0600 Fax: 617. = 109 Smith Place, Cannbridge, MA 02138 Tel. 617-441-0600 Fax 617-497-8800 Cambridge Technology's line

Kleinfeld, David

2

Bibliography Anderson, J.R. (1983). Architecture of cognition. Cambridge, MA: Harvard  

E-Print Network (OSTI)

1 Bibliography Anderson, J.R. (1983). Architecture of cognition. Cambridge, MA: Harvard University and Computer Representations. Cambridge: Cambridge University Press. #12;2 Coelho, S. M., and Séré, M. (1998. diSessa, A. (2000). Changing minds: Computers, learning and literacy. MIT Press. Fauconnier, G. and M

Maryland at College Park, University of

3

Pressure calibrations for cell filling Harvard-Smithsonian Center for Astrophysics, Cambridge, MA 02138  

E-Print Network (OSTI)

, Cambridge, MA 02138 (1/20/00) Purpose: To describe procedures useful in filling various gas sample cells to 77 K, and thus eas- ily condense xenon into the cell. Practically, this means that all the gas the gases in the cell are valid only for a binary gas mixture where one of the gases can be condensed (i

Walsworth, Ronald L.

4

Zero-Waste Events Harvard Office for Sustainability, 46 Blackstone Street, Cambridge, MA 02139 www.green.harvard.edu  

E-Print Network (OSTI)

Zero-Waste Events Harvard Office for Sustainability, 46 Blackstone Street, Cambridge, MA 02139 www.green-compostable materials (i.e. coffee stirrers, tea in foil bags, little creamers) 3. Determine all food and products

Wolfe, Patrick J.

5

Massachusetts Institute of Technology (MIT) Cambridge, MA Ph.D. in AeroAstro, Jun 2013 Overall GPA: 4.8/5.0  

E-Print Network (OSTI)

EDUCATION Massachusetts Institute of Technology (MIT) Cambridge, MA Ph.D. in AeroAstro, Jun 2013 Massachusetts Institute of Technology (MIT) Cambridge, MA Production in the Innovation Economy (PIE): U method to U.S. marine and ground transportation network Strategic Solar Desalination Network (SSDN) Jun

de Weck, Olivier L.

6

Laboratory Safety 46 Blackstone Street, Cambridge, MA 02139 | T: 617.496.3797 | F: 617.496.5509  

E-Print Network (OSTI)

Aerosol-proof rotors and safety cups for centrifuges Other safety equipment 8 Safe work Practices and PPE of pertinent federal and state government regulations, information about safe work practices, safety equipmentLaboratory Safety 46 Blackstone Street, Cambridge, MA 02139 | T: 617.496.3797 | F: 617.496.5509 www

7

MA.+'  

Office of Legacy Management (LM)

MA.+' MA.+' t -@ . ;' OAK RIDGE NATIONAL LABORATORY i OPtRATED BY MARTIN MARIETTA ENERGY SYSTEMS, INC. FOR THE UNITE0 STATES DEPARTMENT OF ENERGY ,,y , - IhI of ORNL/TM-10053 RESULTS OF THE RADIOLOGICAL SURVEY AT THE VENTRON SITE, BEVERLY, MASSACHUSETTS W. D. Cottrell R. F. Carrier -.- _ ..-. - . . . -~~.- ~~- Printed in the United States of America. Available from National Technical Information Service U.S. Department of Commerce 5285 Port Royal Road, Springfield, Virginia 22161 NTIS price codes-Printed Copy: ~06 Microfiche A01 This report was prepared as an account of work sponsored by an agency of the United StatesGovernment. Neither the U nited StatesGovernment nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or

8

Massachusetts Institute of Technology > AgeLab > 77 Massachusetts Ave, E40-279, Cambridge, MA 02139 Phone: 617.253.4978 > fax: 617.258.7570 > reamer@mit.edu  

E-Print Network (OSTI)

Massachusetts Institute of Technology > AgeLab > 77 Massachusetts Ave, E40-279, Cambridge, MA 02139 or polarity, but they did reveal cognitive processing differences between correct and incorrect responses consistent with MIT's previous effort to assess the impact of typestyle on interface demand in a simulated

de Weck, Olivier L.

9

Massachusetts Institute of Technology > AgeLab > 77 Massachusetts Ave, E40-279, Cambridge, MA 02139 Phone: 617.253.0753 > fax: 617.258.7570 > agelab@mit.edu > agelab.mit.edu  

E-Print Network (OSTI)

Massachusetts Institute of Technology > AgeLab > 77 Massachusetts Ave, E40-279, Cambridge, MA 02139 family member or close friend. Caregivers often assume responsibility for a variety of tasks including are provided by family members, but the supply of family caregivers is unlikely to keep pace with future demand

de Weck, Olivier L.

10

DOE - Office of Legacy Management -- National Research Corp - Cambridge -  

Office of Legacy Management (LM)

Research Corp - Cambridge Research Corp - Cambridge - MA 10 FUSRAP Considered Sites Site: RESEARCH CORP. - CAMBRIDGE (MA.10) Eliminated from consideration under FUSRAP Designated Name: Not Designated Alternate Name: None Location: 70 Memorial Drive , Cambridge , Massachusetts MA.10-1 Evaluation Year: 1987 MA.10-3 Site Operations: Subcontractor under Mallinckrodt; performed research and development on uranium and thorium metal fabrication during the late 1940s. MA.10-3 MA.10-1 Site Disposition: Eliminated - No Authority - Potential for contamination considered remote based on limited scope of activities at the site MA.10-2 MA.10-3 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Uranium, Thorium MA.10-3 MA.10-4 MA.10-1 Radiological Survey(s): None Indicated

11

senseable city cambridge (ma) | 22 oct 2010  

E-Print Network (OSTI)

at a coal-fired power plant exploded, severely injuring six workers and resulting in hundreds of thousand;Accident at power plant in Connecticut, 2009 #12;The cost of accidents... "Our results show that but momentous milestone: for the first time in history more than half its human population, 3.3 billion people

Gabrieli, John

12

MA 22100  

E-Print Network (OSTI)

MA 22100 002 - UNIV 017 MWF 08:30am - Smith, Gabriel (MATH 741); MA 22100 003 - UNIV 017 MWF 09:30am - Naughton, Dominic (MATH 848); MA 22100...

13

MA 16100  

E-Print Network (OSTI)

MA 16100, Fall 2014. Plane Analytic Geometry And Calculus I. Course Info. Syllabus Emergency Preparedness Syllabus Attachment Course Calendar...

14

MA 26100  

E-Print Network (OSTI)

Differential calculus of several variables; multiple integrals. Introduction to vector calculus. Not open to students with credit in MA 174 or 271. Typically offered...

15

MA 221  

E-Print Network (OSTI)

MA 22100-22200 is a two-semester sequence in the technique of calculus for students enrolled in certain technical curricula. Not available for credit toward...

16

MA 222  

E-Print Network (OSTI)

MA 222, Spring 2008. Calculus For Technology II ... Contact the Webmaster for technical and content concerns about this webpage. Copyright 2010, Purdue...

17

MA 30300  

E-Print Network (OSTI)

Course Description. Credit Hours: 3.00. This is a methods course for juniors in any branch of engineering and science, designed to follow MA 262.

18

Bringing chemistry to Cambridge  

Science Journals Connector (OSTI)

...2006 book-review Book Review Bringing chemistry to Cambridge J.S Rowlinson * * Author...ac.uk ) Physical and Theoretical Chemistry Laboratory, South Parks Road, Oxford...C.D Haley, eds, The 1702 chair of chemistry at Cambridge: transformation and change...

2006-01-01T23:59:59.000Z

19

DOE - Office of Legacy Management -- Nuclear Metals Inc - MA 09  

Office of Legacy Management (LM)

Metals Inc - MA 09 Metals Inc - MA 09 FUSRAP Considered Sites Site: NUCLEAR METALS, INC. (MA.09) Eliminated from consideration under FUSRAP - Licensed facility - included in NRC action plan (Site Decommissioning Management Plan) in 1990 for cleanup Designated Name: Not Designated Alternate Name: None Location: 1555 Massachusetts Ave. , Cambridge , Massachusetts MA.09-2 Evaluation Year: 1987 MA.09-1 Site Operations: Produced natural uranium tubes for Savannah River reactor program and fabricated power reactor fuel elements under AEC/NRC license. MA.09-4 MA.09-3 Site Disposition: Eliminated - No Authority under FUSRAP - AEC licensed operation MA.09-1 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Uranium, Thorium MA.09-1 Radiological Survey(s): None Indicated

20

MA.2  

Office of Legacy Management (LM)

IS .:,I. ;' IS .:,I. ;' MA.2 0 y-AU Mr. M ichael Matt W a tertown Redevelopment Authority 319 Arlington Street W a tertown, Massachusetts 02172 Dear Mr. Matt: The Department of Energy is evaluating the radiological condition of sites that were utilized under the Manhattan Engineer District and/or the Atomic Energy C o m m ission in the early years of nuclear energy development to determine whether they need remedial action and whether the Department has authority to perform such action. As you know from information previously sent to you, portions of the W a tertown Arsenal in W a tertown, Massachusetts, were identified as possible sites. The areas investigated included those areas which were the sites of Buildings 34, 41, and 421 and the GSA site. The enclosed documents, which represent the Department's review of the

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

MaRIE  

NLE Websites -- All DOE Office Websites (Extended Search)

Materials Science MaRIE aboutassetsimagesicon-faces.jpg MaRIE MaRIE is the experimental facility needed to control the time-dependent properties of materials for national...

22

Cambridge, Massachusetts: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Massachusetts: Energy Resources Massachusetts: Energy Resources (Redirected from Cambridge, MA) Jump to: navigation, search Equivalent URI DBpedia Coordinates 42.3750969°, -71.1056079° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.3750969,"lon":-71.1056079,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

23

The Cambridge Handbook of Literacy  

E-Print Network (OSTI)

in another language. In The Handbook of Literacy, Olson andand others. The reader of the Handbook will not only have aThe Cambridge Handbook of Literacy edited by David R. Olson

Joaquin, Anna Dina L

2009-01-01T23:59:59.000Z

24

To appear in P. Robbins and M. Aydede (Eds.). Cambridge handbook of situated cognition. Cambridge: Cambridge University Press.  

E-Print Network (OSTI)

To appear in P. Robbins and M. Aydede (Eds.). Cambridge handbook of situated cognition. Cambridge understanding of the situatedness of cognition does not require the denial that the proper locus of control

Bechtel, William

25

DOE - Office of Legacy Management -- Beverly MA Site - MA 04  

Office of Legacy Management (LM)

Beverly MA Site - MA 04 Beverly MA Site - MA 04 FUSRAP Considered Sites Beverly, MA Alternate Name(s): Metal Hydrides, Inc. Ventron Corporation MA.04-1 Location: Congress Street, Beverly, Massachusetts MA.04-4 Historical Operations: Provided uranium metal production under contract with MED. Thorium and radium contamination occurred from non-MED operations. MA.04-6 Eligibility Determination: Eligible MA.04-1 Radiological Survey(s): Assessment Survey, Verification Survey MA.04-4 MA.04-7 Site Status: Certified- Certification Basis, Federal Register Notice included MA.04-5 MA.04-6 MA.04-7 Long-term Care Requirements: Long-Term Surveillance and Maintenance Requirements for Remediated FUSRAP Sites S07566_FUSRAP Also see Beverly, MA, Site Documents Related to Beverly, MA Beverly Site Aerial Photograph

26

MA 16020 -- CALCULATOR POLICY  

E-Print Network (OSTI)

MA 16020 -- CALCULATOR POLICY. A ONE-LINE scientific calculator is REQUIRED. No other calculator is allowed. RECOMMENDED: TI-30Xa calculator

OwenDavis

2014-08-20T23:59:59.000Z

27

Washington, DC'  

Office of Legacy Management (LM)

of. Energy of. Energy Washington, DC' 26585 , The Honorable Gene Eriquez .~ City Hall I55 Deer Hill Avenue + Danbury/Connecticut 06180 .. -r. - Dear Mayor Eriquez: Secretary of Energy Hazel O!Leary has .announced a knew approach -to openness in. the Department of Energy (DOE) and its communications with the public. In support of th,is initiative, we are,pleased to forward the enclosed information, related to the former Sperry Products,'.Inc. site in your jurisdiction ,that performed,work for DOE or its predecessor agencies. Th,is informatipn is provided,for your information, use, and retenti~oh. DOE's Formeily Utilized Sites Remedial Action Program is responsible for. identification of sites used by'DOE's predecessor agencies, determining their current radiological condition and,

28

Bi-directional dc-dc Converter  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Nov Dec Phase II, Timeline 2009 Jan Feb Mar Apr May Jun Jul Aug Sep Vehicle Interface, FMEA and MTBF Dc-dc Fabrication Validation Data Performance Validation BOM and Cost analysis...

29

MaRIE Presentations  

NLE Websites -- All DOE Office Websites (Extended Search)

certifiable, flexible, and low-cost product-based solutions to many materials problems. MaRIE 1.0 Matter Radiation Interactions in Extremes 1.0 70th Anniversary (pdf) July 27, 2013...

30

CAMBRIDGE HEALTH ALLIANCE Coping with the Boston Marathon Tragedy  

E-Print Network (OSTI)

CAMBRIDGE HEALTH ALLIANCE Coping with the Boston Marathon Tragedy The Cambridge Health Alliance-591-6462. For Child & Adolescent Psychiatry, Cambridge Health Alliance offers the following: · Quick access

Chou, James

31

Ookie Ma | Department of Energy  

Energy Savers (EERE)

Ookie Ma About Us Ookie Ma - Policy and Analysis, Portfolio Manager, Office of Energy Efficiency and Renewable Energy Most Recent Fun Fact Friday: Geeking Out on Energy Data...

32

Bi-directional dc-dc Converter  

Energy.gov (U.S. Department of Energy (DOE))

2009 DOE Hydrogen Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting, May 18-22, 2009 -- Washington D.C.

33

Bi-directional dc-dc Converter  

Energy.gov (U.S. Department of Energy (DOE))

2010 DOE Vehicle Technologies and Hydrogen Programs Annual Merit Review and Peer Evaluation Meeting, June 7-11, 2010 -- Washington D.C.

34

NEWNHAM COLLEGE CAMBRIDGE CB3 9DF  

E-Print Network (OSTI)

NEWNHAM COLLEGE CAMBRIDGE CB3 9DF F:\\EVENTS\\Forms\\2013\\Y12 Science Day Form 2013.doc YEAR 12 SCIENCE DAY: SATURDAY 16th MARCH 2013 STUDENTS: If you are considering coming to Cambridge to study Natural Sciences, Computer Sciences or Engineering, why not come to our Science Day? Join Newnham students

Travis, Adrian

35

Basic DC Meter Design ECE 2100 Circuit Analysis Laboratory  

E-Print Network (OSTI)

Basic DC Meter Design ECE 2100 Circuit Analysis Laboratory updated 8 January 2008 Pre-Laboratory Assignment 1. Design an ammeter with full scale current IFS equal to 5 mA using a meter movement rated at 0.5 mA and 100 mV. 2. Design a voltmeter with a full scale voltage VFS equal to 10 V using the meter

Miller, Damon A.

36

Cambridge Energy Alliance | Open Energy Information  

Open Energy Info (EERE)

Cambridge Energy Alliance Cambridge Energy Alliance Jump to: navigation, search Logo: Cambridge Energy Alliance Name Cambridge Energy Alliance Address 1385 Cambridge St Place Cambridge, Massachusetts Zip 02139 Region Greater Boston Area Website http://www.cambridgeenergyalli Notes Helps Cambridge residential and business customers identify and arrange financing for all cost-effective efficiency and renewable measures Coordinates 42.3737272°, -71.1007089° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.3737272,"lon":-71.1007089,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

37

MA 152 Exam 1 Memo  

E-Print Network (OSTI)

that evening on the MA 15910 web page (www.math.purdue.edu/MA15910). 3) The exam is self-explanatory. No questions will be allowed unless a student...

math

2015-01-21T23:59:59.000Z

38

Effects of Travel Reduction and Efficient Driving on Transportation...  

NLE Websites -- All DOE Office Websites (Extended Search)

Systematics, Inc. (Cambridge, MA), for the U.S. Department of Energy, Washington, DC. DOEGO-102013-3704. 98 pp. vi REPORT CONTRIBUTORS AND ROLES National Renewable Energy...

39

RES D.C.  

Energy.gov (U.S. Department of Energy (DOE))

RES DC, hosted by the National Center for American Indian Enterprise Development (The National Center), will feature access to respected tribal leaders, members of congress, federal agency...

40

MA 23100 and MA 23200 - FINAL EXAM INFORMATION Fall 2009 ...  

E-Print Network (OSTI)

MSEE = Materials and Electrical Engineering. You may refer to the campus map for their locations. For MA 23100, there's a link (Seating Arrangement) in the...

2009-12-15T23:59:59.000Z

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

DE-MA0002512  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Award No. 2. Modification No. 3. Effective Date Award No. 2. Modification No. 3. Effective Date 4. CFDA No. DE-MA0002512 03/27/2012 ASSISTANCE AGREEMENT 7. Period of Performance 6. Sponsoring Office 5. Awarded To Other Cooperative Agreement Grant test 10. Purchase Request or Funding Document No. 9. Authority 8. Type of Agreement 11. Remittance Address 12. Total Amount 13. Funds Obligated Govt. Share: $0.00 Cost Share : $0.00 Total : $0.00 This action: $0.00 Total : $0.00 test 14. Principal Investigator 15. Program Manager 16. Administrator test 19. Submit Reports To 18. Paying Office 17. Submit Payment Requests To 20. Accounting and Appropriation Data See Schedule 21. Research Title and/or Description of Project For the Recipient For the United States of America 22. Signature of Person Authorized to Sign

42

Natural Language Engineering http://journals.cambridge.org/NLE  

E-Print Network (OSTI)

Natural Language Engineering http://journals.cambridge.org/NLE Additional services for Natural1351324912000289 Request Permissions : Click here Downloaded from http://journals.cambridge.org/NLE, IP address information retrieval (search with Google, Bing, etc.), but

Bergler, Sabine

43

Discovery and utilization of sorghum genes (Ma5/Ma6)  

DOE Patents (OSTI)

Methods and composition for the production of non-flowering or late flowering sorghum hybrid. For example, in certain aspects methods for use of molecular markers that constitute the Ma5/Ma6 pathway to modulate photoperiod sensitivity are described. The invention allows the production of plants having improved productivity and biomass generation.

Mullet, John E; Rooney, William L; Klein, Patricia E; Morishige, Daryl; Murphy, Rebecca; Brady, Jeff A

2012-11-13T23:59:59.000Z

44

Taught degree MA in Philosophy  

E-Print Network (OSTI)

Philosophy Taught degree MA in Philosophy 1 year full time/2 years part time This MA offers an advanced general grounding in philosophy, which forms a good basis for further research. It includes modules in both the analytic and continental traditions of philosophy, reflecting the wide range

Sussex, University of

45

NREL: Energy Sciences - Jie Ma  

NLE Websites -- All DOE Office Websites (Extended Search)

Jie Ma Jie Ma Postdoctoral Researcher Photo of Jie Ma Phone: (303) 384-6511 Email: jie.ma@nrel.gov At NREL Since: 2010 Dr. Ma graduated from the University of Science and Technology of China in 2004 and received a Ph.D. degree from Institute of Physics, Chinese Academy of Sciences in 2009. Jie joined the Computational Materials Science Team at NREL as a postdoctoral researcher in March, 2010. He is currently working on computational design and characterization of nanoscale materials for doping, water splitting, and solar cells, using quantum mechanical electronic structure calculation and molecular dynamics simulation techniques. Research Interests Low-dimensional systems (quantum dots, nanotube and nanowires, and surfaces) Doping in semiconductors. Solar cell and water splitting.

46

MA Mortenson | Open Energy Information  

Open Energy Info (EERE)

Mortenson Mortenson Jump to: navigation, search Name MA Mortenson Place Minnesota Zip 55440-0710 Sector Solar, Wind energy Product Construction and building firm active in the installation of wind and solar farms. References MA Mortenson[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. MA Mortenson is a company located in Minnesota . References ↑ "MA Mortenson" Retrieved from "http://en.openei.org/w/index.php?title=MA_Mortenson&oldid=348551" Categories: Clean Energy Organizations Companies Organizations Stubs What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load)

47

Paper Publishing is Here to Stay: The Cambridge Planetary Handbook by Michael E Bakich, 1999, Cambridge University Press, 19.95, hbk, ISBN 0 521 63280 3  

Science Journals Connector (OSTI)

......Stay: The Cambridge Planetary Handbook by Michael E Bakich, 1999...stay The Cambridge Planetary Handbook by Michael E Bakich, 1999...Bakich's Cambridge Planetary Handbook is a scholarly guide to the...presentations compare? What does the electronic presentation......

Sue Bowler

2000-04-01T23:59:59.000Z

48

DOE - Office of Legacy Management -- Indian Orchard MA Site - MA 08  

NLE Websites -- All DOE Office Websites (Extended Search)

Indian Orchard MA Site - MA 08 Indian Orchard MA Site - MA 08 FUSRAP Considered Sites Indian Orchard, MA Alternate Name(s): Chapman Valve Manufacturing Company Chapman Valve Site Crane Company MA.08-3 MA.08-4 Location: 203 Hampshire Street, Indian Orchard, Massachusetts MA.08-2 Historical Operations: Machined extruded natural uranium rods and supplied valves and other products to MED and AEC. Also machined natural uranium rods into slugs for Brookhaven National Laboratory. MA.08-6 MA.08-7 MA.08-8 MA.08-14 Eligibility Determination: Eligible MA.08-2 Radiological Survey(s): Assessment Survey, Verification Survey MA.08-11 MA.08-12 Site Status: Certified - Certification Basis, Federal Register Notice included. MA.08-13 MA.08-14 Long-term Care Requirements: Long-Term Surveillance and Maintenance Requirements for Remediated FUSRAP Sites S07566_FUSRAP

49

MA - Office of Management - Energy Conservation Plan  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

MA Energy Conservation Plan MA Energy Conservation Plan January 2010 1 Office of Management Office-Level Energy Conservation Plan January 2010 I. BACKGROUND This energy conservation plan represents an effort to reduce energy consumption within Office of Management (MA) office spaces and to increase employee awareness of and participation in energy conservation measures. II. SCOPE The plan and procedures in this document apply to all Office of Management (MA) office suites in the Forrestal and Germantown Facilities as well as the 950 L'Enfant Plaza Building. The actions and procedures set forth in this plan apply to each separate MA office suite as follows: MA-1: 4A-107 MA-43: 1F-039 MA-70: 7E-074 MA-1.1: 7E-028 MA-43: 1F-037 MA-70: 7E-054 MA-30: GH-081 MA-43:

50

Category:Boston, MA | Open Energy Information  

Open Energy Info (EERE)

Boston, MA Boston, MA Jump to: navigation, search Go Back to PV Economics By Location Media in category "Boston, MA" The following 16 files are in this category, out of 16 total. SVFullServiceRestaurant Boston MA Massachusetts Electric Co.png SVFullServiceRestauran... 67 KB SVHospital Boston MA Massachusetts Electric Co.png SVHospital Boston MA M... 65 KB SVLargeHotel Boston MA Massachusetts Electric Co.png SVLargeHotel Boston MA... 65 KB SVLargeOffice Boston MA Massachusetts Electric Co.png SVLargeOffice Boston M... 65 KB SVMediumOffice Boston MA Massachusetts Electric Co.png SVMediumOffice Boston ... 65 KB SVMidriseApartment Boston MA Massachusetts Electric Co.png SVMidriseApartment Bos... 65 KB SVOutPatient Boston MA Massachusetts Electric Co.png SVOutPatient Boston MA...

51

Reflections on Cambridge: Reflections on Isaac Newton, discovery and Cambridge - with apple tree  

E-Print Network (OSTI)

Reflections about the life and effects of Isaac Newton in Cambridge, filmed outside Trinity College, with the descendant of his apple tree behind (and the rooms where he lived and worked). Filmed by Xu Bei in 2009....

Macfarlane, Alan

52

UNIVERSITY OF CAMBRIDGE Faculty of Mathematics  

E-Print Network (OSTI)

UNIVERSITY OF CAMBRIDGE Faculty of Mathematics MATHEMATICS FOR THE NATURAL SCIENCES WORKBOOK Mathematics is an essential tool for all scientists. In the first year of the Natural Sciences Tripos, there are three mathematics courses: Mathematics (courses A or B); Quantitative Biology; and Elementary

Lasenby, Joan

53

Summer 2009 Chemistry Olympiad in Cambridge  

E-Print Network (OSTI)

, then head of organic chemistry at the University of Cape Town, but it was at the time of the first electionsSummer 2009 Chemistry Olympiad in Cambridge Protein folding ­ and misfolding about the academic staff in the department, but I looked through the book- let they sent me and I

Keeler, James

54

Campus and Residential Services Cambridge and Cavendish  

E-Print Network (OSTI)

Campus and Residential Services Cambridge and Cavendish Halls Handbook 2011 ­ 2012 #12;1 WELCOME We Facilities Manager September 2011 This Handbook supplements your Terms of Occupancy. They both contain of the `key' Terms. This list does not contain all of the Terms and reading it should not replace a careful

55

CAES MaCS Home  

NLE Websites -- All DOE Office Websites (Extended Search)

is largely made possible through its partnership with the Advanced Test Reactor National Scientific User Facility (ATR NSUF). MaCS is complementary to the Boise State Center for...

56

MA Org Chart, January 15, 2015  

Energy Savers (EERE)

MA-66 MA-60 Paul Bosco, Director Pat Ferraro, Deputy Director Jay Glascock, Senior Advisor MA-80 Office of the Ombudsman Rita R. Franklin, Director Cathy Barchi, Dep. Director...

57

MA Org Chart, October 9, 2014  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Montoya, Dep. Director Office of Administrative Management and Support Office of Logistics and Facility Operations Office Travel Management MA-45 Umeki Thorne, Director MA-42...

58

MA Org Chart, October 20, 2014  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Montoya, Dep. Director Office of Administrative Management and Support Office of Logistics and Facility Operations Office Travel Management MA-45 Umeki Thorne, Director MA-42...

59

Cambridge Design & Development | Open Energy Information  

Open Energy Info (EERE)

MA Information About Partnership with NREL Partnership with NREL Yes Partnership Type Test & Evaluation Partner Partnering Center within NREL Electricity Resources & Building...

60

Please return this completed form to The Cambridge Foundation, 1 Quayside, Bridge Street, Cambridge CB5 8AB Do not send this form to your bank, return it directly to the Cambridge Foundation  

E-Print Network (OSTI)

Please return this completed form to The Cambridge Foundation, 1 Quayside, Bridge Street, Cambridge CB5 8AB Do not send this form to your bank, return it directly to the Cambridge Foundation The Cambridge Foundation Isaac Newton Institute for Mathematical Sciences Please insert name and address below

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

US NE MA Site Consumption  

Gasoline and Diesel Fuel Update (EIA)

NE MA NE MA Site Consumption million Btu $0 $500 $1,000 $1,500 $2,000 $2,500 $3,000 US NE MA Expenditures dollars ALL ENERGY average per household (excl. transportation) 0 2,000 4,000 6,000 8,000 10,000 12,000 US NE MA Site Consumption kilowatthours $0 $250 $500 $750 $1,000 $1,250 $1,500 US NE MA Expenditures dollars ELECTRICITY ONLY average per household * Massachusetts households use 109 million Btu of energy per home, 22% more than the U.S. average. * The higher than average site consumption results in households spending 22% more for energy than the U.S. average. * Less reliance on electricity for heating, as well as cool summers, keeps average site electricity consumption in the state low relative to other parts of the U.S. However, spending on electricity is closer to the national average due to higher

62

US NE MA Site Consumption  

U.S. Energy Information Administration (EIA) Indexed Site

NE MA NE MA Site Consumption million Btu $0 $500 $1,000 $1,500 $2,000 $2,500 $3,000 US NE MA Expenditures dollars ALL ENERGY average per household (excl. transportation) 0 2,000 4,000 6,000 8,000 10,000 12,000 US NE MA Site Consumption kilowatthours $0 $250 $500 $750 $1,000 $1,250 $1,500 US NE MA Expenditures dollars ELECTRICITY ONLY average per household * Massachusetts households use 109 million Btu of energy per home, 22% more than the U.S. average. * The higher than average site consumption results in households spending 22% more for energy than the U.S. average. * Less reliance on electricity for heating, as well as cool summers, keeps average site electricity consumption in the state low relative to other parts of the U.S. However, spending on electricity is closer to the national average due to higher

63

Multiplatform Dynamic System Simulation of a DC-DC Converter.  

E-Print Network (OSTI)

??The work presented in this paper focuses on the usability testing for the Open-Modelica. The modeling and simulation of the BMR450 DC-DC converter is also (more)

Song, Wenpeng

2012-01-01T23:59:59.000Z

64

Cambridge, Massachusetts: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Cambridge, Massachusetts: Energy Resources Cambridge, Massachusetts: Energy Resources Jump to: navigation, search Equivalent URI DBpedia Coordinates 42.3750969°, -71.1056079° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.3750969,"lon":-71.1056079,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

65

MA Org Chart, August 01, 2013  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

MA-1 MA-1 Ingrid Kolb, Director Chief Acquisition Officer (Vacant) Laurie Morman, Chief of Staff Office of Resource Management and Planning MA-1.1 Marilyn Dillon, Director Willie Mae Ingram, Dep. Director (Acting) Office of Acquisition & Project Management Paul Bosco, Director David Boyd, Dep. Director Jay Glascock, Senior Advisor Office of Policy MA-63 Berta Schreiber Director Office of Contract Management Patrick Ferraro Director Office of Project Management Michael Peek Director Office of Headquarters Procurement Services Mark Brady Director Office of Property Management Carmelo Melendez Director MA-60 Office of Scheduling and Advance Anthony Rediger, Director James Covey, Dep. Director MA-10 MA-30 MA-40 MA-70 MA-90 Office of Aviation

66

E-Print Network 3.0 - astrophysical observatory cambridge Sample...  

NLE Websites -- All DOE Office Websites (Extended Search)

Rt. Hon. John Denham MP Summary: physics University of Cambridge Particle physics phenomenology Royal Observatory Edinburgh Astrophysics... physics University of Cambridge High...

67

WIND DATA REPORT Nantucket, MA  

E-Print Network (OSTI)

. Rogers Anthony F. Ellis July 12, 2006 Report template version 1.3 Renewable Energy Research Laboratory Research Laboratory (RERL) at the University of Massachusetts, Amherst in the course of performing work 12, 2006 Renewable Energy Research Laboratory Page 1 University of Massachusetts, Amherst Amherst, MA

Massachusetts at Amherst, University of

68

WIND DATA REPORT Wellfleet, MA  

E-Print Network (OSTI)

by the Renewable Energy Research Laboratory (RERL) at the University of Massachusetts, Amherst in the course, 2007 Renewable Energy Research Laboratory Page 1 University of Massachusetts, Amherst Amherst, MA 01003. Manwell Anthony L. Rogers Anthony F. Ellis May 2, 2007 Report template version 3.0 Renewable Energy

Massachusetts at Amherst, University of

69

WIND DATA REPORT Nantucket, MA  

E-Print Network (OSTI)

by the Renewable Energy Research Laboratory (RERL) at the University of Massachusetts, Amherst in the course L. Rogers Anthony F. Ellis March 30, 2006 Report template version 1.3 Renewable Energy Research Laboratory University of Massachusetts, Amherst 160 Governors Drive, Amherst, MA 01003 www

Massachusetts at Amherst, University of

70

Washington. DC,20585  

Office of Legacy Management (LM)

Washington. DC,20585 Washington. DC,20585 MAY' i 1995 .- The Honorable Freeman R. Bosley, Jr. ' r City Hall 1200 Narket Street St. Louis, Missouri 63103 Dear Mayor Bosley: ,'~ ,. : !' Secretary of Energy Hazel O'Leary'has announced a new approach to'openness'in " the Department of,Energy"(DOE) and its communications with the pu~blic. In 'support of this initiative, we are pleased to forward the enclosed information rel,ated to the former Petrolite Corp. site in your jurisdiction that,performed, work for DDE or,i.ts predecessor agencies. your information, use, and retention. This information is provided for DDE's Formerly Utilized Sites Remedial Action Program is responsible for identification of sites used by DDE's predecessor agencies, determining their

71

I ' Washington, DC'  

Office of Legacy Management (LM)

' Washington, DC' ' Washington, DC' 20585 The.Honorable Don Trotter, 102' Public Square Clarksville, Tennessee '37040 '_ _' ' Dear Mayor Trotter: '. Secretary of Energy Hazel .O'Leary has announced a new the Department of Energy (DOE) and its communications support of this initiative, we are pleased to forward related to the Clarksville Foundry.& Machine Co. site approach to openness in with the publ,ic'. In " the~enclosed~information in your'jurisdiction that performed work for DOE or its predecessor'agencies. This information. is provided, for.your information, use, and retention. remedial action conservative' set of technical investigations to assure environment. If'you have any questions, please feel free~to call DrI W. Alexander Uilliams 301-427-1719 of my staff.

72

InThrMa | Open Energy Information  

Open Energy Info (EERE)

InThrMa InThrMa Jump to: navigation, search Tool Summary LAUNCH TOOL Name: InThrMa Agency/Company /Organization: InThrMa Sector: Energy Focus Area: - HVAC Resource Type: Software/modeling tools User Interface: Website, Mobile Device Website: www.inthrma.com/ Web Application Link: www.inthrma.com/ Cost: Paid Language: English InThrMa Screenshot References: InThrMa[1] Logo: InThrMa Web based HVAC EMS for Internet connected thermostats, focusing on energy efficiency, including Auto Demand Response capabilities. Harnessing Data & Technology To Derive HVAC Efficiency Overview InThrMa's HVAC Energy Management Suite (EMS) allows users to manage and optimize their HVAC systems from any web browser or mobile phone. The InThrMa EMS provides various tools for programming, monitoring and

73

Natural Language Engineering http://journals.cambridge.org/NLE  

E-Print Network (OSTI)

Natural Language Engineering http://journals.cambridge.org/NLE Additional services for Natural1351324912000101 Request Permissions : Click here Downloaded from http://journals.cambridge.org/NLE, IP address: 79 as anchors that delimit the search space. We use a large monolingual corpus to rank and filter

Wintner, Shuly

74

Natural Language Engineering http://journals.cambridge.org/NLE  

E-Print Network (OSTI)

Natural Language Engineering http://journals.cambridge.org/NLE Additional services for Natural Permissions : Click here Downloaded from http://journals.cambridge.org/NLE, IP address: 79.181.48.102 on 29-processing steps for a variety of natural language processing applications, from search and information extraction

Wintner, Shuly

75

The Cambridge Forum for Sustainability and the Environment Members: Biographies  

E-Print Network (OSTI)

and development economics · state-society interactions in development · public policy in the developing world · biodiversity conservation e-mail: bv101@cam.ac.uk and for more information see his website Chris Gilligan-founder of Cambridge Wireless, co-founder and Chairman of Cambridge Angels and is a member of the IET Communications

Edinburgh, University of

76

Taught degrees MA in Literature and Philosophy  

E-Print Network (OSTI)

Philosophy Taught degrees MA in Literature and Philosophy 1 year full time/2 years part time This degree is taught jointly by Philosophy and English faculty. Refer to page 87 for details. MA in Philosophy 1 year full time/2 years part time This MA offers an advanced general grounding in philosophy

Sussex, University of

77

Office of Information Resources (MA-90) | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Office of Information Resources (MA-90) Office of Information Resources (MA-90) Freedom of Information 2007 Annual Report Office of Information Resources (MA-90) More Documents &...

78

Ma-Brueckner correlation energy  

Science Journals Connector (OSTI)

We point out that the e2 dependence of the term in the correlation energy of a high-density electron gas, proportional to the gradient squared of the charge density, was rigorously derived by Ma and Brueckner only for infinitely long-wavelength variations in the charge density. We also correct an error made in obtaining the coefficient of this term which arose because of long-range Coulomb anomalies in the exchange energy which they subtracted from the exchange-correlation energy.

Leonard Kleinman and T. Tamura

1989-08-15T23:59:59.000Z

79

Departmentaf Energy Washington, DC  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Departmentaf Departmentaf Energy Washington, DC 20585 MAR 4 1998 MEMORANDUM FOR: James H. Chafin, AL Robert Fisher, CH Steven Hamel, OR William Daubenspeck, LL James Hanley, SAN Robert Southworth, RL Harold Dixon, SR \ Lisa Jarr, FETC"/"',,,-' ( ~ ( ) ( I C{ \'"~V FROM: Paul A. Gottlieb'<,. ~ ' \ Assistant General Counsel . for Technology Transfer / and Intellectual Property SUBJECT: U.S. Competitiveness Provision. Except for the cases discussed further below, attached is the U.S. Competitiveness provision which you should begin providing as our initial negotiating position to inventors/contractors requesting identified and, advance patent waivers. Of course, it is not· expected that every inventor/contractor will agree to the exact language in the provision, in which case modifications to the provision can be made. In those cases where substantial changes are contemplated,

80

Washington, DC,20585  

Office of Legacy Management (LM)

>/gGq ' >/gGq ' ,, ' .. Department of Edgy Washington, DC,20585 ,I ' , APR 0 4 1995 The Honorable Patrick Ungaro 26 S. Phelps Street Youngstown, Ohio 44503 .' Dear );layor.Ungaro: Secretary of'Energy Hazel O'Leary has announced a new approach to openness in the Oepartment of Energy (DOE) and its coannunications with the public. In support of this initiative, we are pleased to forward the,enclosed information related to the former Ajax-Hagnethermic C,orp. site in your jurisdiction that performed work for DOE's predecessoragencies. This information is~provided for your information, use, and retention. DOE's Formerly Utilized Sites Remedial Action Program is responsible for identificationof sites used by DOE's predecessor agencies, determining their current radiological condition and, where it has authority, performing-

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

D.C.  

NLE Websites -- All DOE Office Websites (Extended Search)

Future scientists advance to national Future scientists advance to national level April 3, 2012 Science Bowl winners represent NM in Washington, D.C. A team from Los Alamos bested 39 other teams from around New Mexico in the 10- hour New Mexico Regional Science Bowl, held recently at Albuquerque Academy. The team went on to represent New Mexico in the 22nd Annual Department of Energy (DOE) National Science Bowl. In addition to their travel expenses, the team also won $5,000 for their school. The team consists of students, Alexander Wang, Micha Ben-Naim, Scott Carlsten, Lorenzo Venneri and Kevin Gao, and Coach, Paolo Venneri. - 2 - Albuquerque Academy took second place and La Cueva High School in Albuquerque placed third in the "Jeopardy!"-style event. During the competition, students are asked

82

The Foundations of Causal Decision Theory, by James Joyce, Cambridge: Cambridge University Press, 1999, Pp. xii + 268. H/b 45.00.  

E-Print Network (OSTI)

The Foundations of Causal Decision Theory, by James Joyce, Cambridge: Cambridge University Press of the recent philosophical literature, including rational decision making and probabilistic theories historical introduction to the topic of decision theory (including an incisive critical discussion of Leonard

Fitelson, Branden

83

TIAX, LLC. Acorn Park Cambridge, Massachusetts  

NLE Websites -- All DOE Office Websites (Extended Search)

TIAX, LLC. TIAX, LLC. Acorn Park Cambridge, Massachusetts 02140-2390 75570-00 Structural Limitations in the Scale-up of Anode Supported SOFCs Final Report to DOE NETL October 9th, 2002 SS.75570.PARSONS.TASK1.DRFTFiNALRPT.060602.REV1 1 Outline of Final Report 2 Approach & Scope 3 Model Development 1 Background & Objectives 5 Multi Channel SOFC Results 4 Single Channel SOFC Results 6 Limitations for Cell Size 7 Summary 0 Executive Summary A Appendix SS.75570.PARSONS.TASK1.DRFTFiNALRPT.060602.REV1 2 * The SECA strategy is to develop cost-effective modular planar SOFC stack technology that could be applied to a broad range of applications: - Application of similar stack design to multiple applications would accelerate stack cost reduction - Applications range from small-capacity applications (< 10 kW) with 1-4 stacks, to

84

Cambridge Project Development | Open Energy Information  

Open Energy Info (EERE)

Development Development Jump to: navigation, search Name Cambridge Project Development Place Miami, Florida Product Florida-based firm that builds wate management and waste to energy projects. Coordinates 25.728985°, -80.237419° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":25.728985,"lon":-80.237419,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

85

Triple voltage dc-to-dc converter and method  

DOE Patents (OSTI)

A circuit and method of providing three dc voltage buses and transforming power between a low voltage dc converter and a high voltage dc converter, by coupling a primary dc power circuit and a secondary dc power circuit through an isolation transformer; providing the gating signals to power semiconductor switches in the primary and secondary circuits to control power flow between the primary and secondary circuits and by controlling a phase shift between the primary voltage and the secondary voltage. The primary dc power circuit and the secondary dc power circuit each further comprising at least two tank capacitances arranged in series as a tank leg, at least two resonant switching devices arranged in series with each other and arranged in parallel with the tank leg, and at least one voltage source arranged in parallel with the tank leg and the resonant switching devices, said resonant switching devices including power semiconductor switches that are operated by gating signals. Additional embodiments having a center-tapped battery on the low voltage side and a plurality of modules on both the low voltage side and the high voltage side are also disclosed for the purpose of reducing ripple current and for reducing the size of the components.

Su, Gui-Jia (Knoxville, TN)

2008-08-05T23:59:59.000Z

86

MA transmutation performance in the optimized MYRRHA  

SciTech Connect

MYRRHA (multi-purpose hybrid research reactor for high-tech applications) is a multipurpose research facility currently being developed at SCK-CEN. It will be able to work in both critical and subcritical modes and, cooled by lead-bismuth eutectic. In this paper the minor actinides (MA) transmutation capabilities of MYRRHA are investigated. (Pu + Am, U) MOX fuel and (Np + Am + Cm, Pu) Inert Matrix Fuel test samples have been loaded in the central channel of the MYRRHA critical core and have been irradiated during five cycles, each one consisting of 90 days of operation at 100 MWth and 30 days of shutdown. The reactivity worth of the test fuel assembly was about 1.1 dollar. A wide range of burn-up level has been achieved, extending from 42 to 110 MWd/kg HM, the samples with lower MA-to-Pu ratios reaching the highest burn-up. This study has highlighted the importance of the initial MA content, expressed in terms of MA/Pu ratio, on the transmutation rate of MA elements. For (Pu + Am, U) MOX fuel samples, a net build-up of MA is observed when the initial content of MA is very low (here, 1.77 wt% MA/Pu) while a net decrease in MA is observed in the sample with an initial content of 5 wt%. This suggests the existence of some 'equilibrium' initial MA content value beyond which a net transmutation is achievable.

Malambu, E.; Van den Eynde, G.; Fernandez, R.; Baeten, P.; Ait Abderrahim, H. [SCK-CEN, Boeretang 200, BE-2400 Mol (Belgium)

2013-07-01T23:59:59.000Z

87

Cambridge Energy Research Associates CERA | Open Energy Information  

Open Energy Info (EERE)

Cambridge Energy Research Associates CERA Cambridge Energy Research Associates CERA Jump to: navigation, search Name Cambridge Energy Research Associates (CERA) Place Cambridge, Massachusetts Zip 2142 Sector Services Product Prominent provider of consultancy and research services to and on the global energy industry. Coordinates 43.003745°, -89.017499° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":43.003745,"lon":-89.017499,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

88

Cambridge in transition : regulating parking in a growing city  

E-Print Network (OSTI)

Parking is regulated today by cities to achieve a variety of goals including traffic reduction, air quality improvement, urban densification, and climate change mitigation. In the City of Cambridge, Massachusetts, parking ...

Ferrentino, Cara Elizabeth

2013-01-01T23:59:59.000Z

89

Catalog of DC Appliances and Power Systems  

E-Print Network (OSTI)

Appliance Efficient DC compatible replacement technology variable-speed compressor and fans run by brushless DC motor in place of single-speed compressors

Garbesi, Karina

2012-01-01T23:59:59.000Z

90

Dc's blog | OpenEI Community  

Open Energy Info (EERE)

The U.S. Department of Energy put out this short inspirational video about Women in Science, Technology, Engineering, and Mathematics (STEM). Dc's picture Submitted by Dc(55)...

91

Catalog of DC Appliances and Power Systems  

E-Print Network (OSTI)

by DC-indifferent electric resistance heating or by DC-and LED lamps Electric resistance heater Incandescentfluorescent or LED) Electric resistance Cooling Motors

Garbesi, Karina

2012-01-01T23:59:59.000Z

92

DOE - Office of Legacy Management -- Shpack Landfill - MA 06  

Office of Legacy Management (LM)

Shpack Landfill - MA 06 Shpack Landfill - MA 06 FUSRAP Considered Sites Shpack Landfill, NY Alternate Name(s): Attleboro, MA Metals and Controls Site Norton Landfill area MA.06-2 MA.06-3 Location: 68 Union Road, Norton, Massachusetts MA.06-2 Historical Operations: No AEC activities were conducted on site. Contamination was suspected from disposal of materials containing uranium and zirconium ash. MA.06-2 MA.06-3 Eligibility Determination: Eligible MA.06-1 Radiological Survey(s): Assessment Surveys MA.06-4 MA.06-5 MA.06-6 Site Status: Cleanup in progress by U.S. Army Corps of Engineers. MA.06-7 MA.06-8 USACE Website Long-term Care Requirements: To be determined upon completion. Also see Documents Related to Shpack Landfill, NY MA.06-1 - DOE Memorandum; Meyers to Hart; Subject: Shpack Landfill,

93

M.A. Silva Dias,  

NLE Websites -- All DOE Office Websites (Extended Search)

1 a 260. 1 a 260. 1 Modelando o Impacto Climático Regional e Remoto do Desmatamento M.A. Silva Dias, 1 R. Avissar, 2 e P. Silva Dias 1,3 As observações e os modelos concordam que os níveis atuais e os padrões de desmatamento da Amazônia de fato intensificam as transferências de massa e energia entre a terra e a atmosfera por meio da criação de circulações impulsionadas termicamente com efeitos significativos sobre a precipitação, mas que variam sazonal e regionalmente. Isso também indicou a necessidade de identificar o limiar onde o aumento do desmatamento realmente implica a diminuição de pluviosidade, conforme apontado pela maioria dos modelos de circulação geral de baixa resolução. Grande parte dos estudos sobre o impacto remoto ainda é exploratória, mas indicam que

94

M.A. POLITICAL SCIENCE Application Checklist  

E-Print Network (OSTI)

M.A. POLITICAL SCIENCE Application Checklist IMPORTANT NOTES 1. Please submit all Application below. 6. Applicants to the M.A. Political Science Program normally should have a four-year baccalaureate degree in Political Science. UNBC and the Political Science Program are committed

Northern British Columbia, University of

95

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current.

Druce, Robert L. (Union City, CA); Kirbie, Hugh C. (Dublin, CA); Newton, Mark A. (Livermore, CA)

1998-01-01T23:59:59.000Z

96

Light-weight DC to very high voltage DC converter  

DOE Patents (OSTI)

A DC-DC converter capable of generating outputs of 100 KV without a transformer comprises a silicon opening switch (SOS) diode connected to allow a charging current from a capacitor to flow into an inductor. When a specified amount of charge has flowed through the SOS diode, it opens up abruptly; and the consequential collapsing field of the inductor causes a voltage and current reversal that is steered into a load capacitor by an output diode. A switch across the series combination of the capacitor, inductor, and SOS diode closes to periodically reset the SOS diode by inducing a forward-biased current. 1 fig.

Druce, R.L.; Kirbie, H.C.; Newton, M.A.

1998-06-30T23:59:59.000Z

97

Switching coordination of distributed dc-dc converters for highly efficient photovoltaic power plants  

DOE Patents (OSTI)

A distributed photovoltaic (PV) power plant includes a plurality of distributed dc-dc converters. The dc-dc converters are configured to switch in coordination with one another such that at least one dc-dc converter transfers power to a common dc-bus based upon the total system power available from one or more corresponding strings of PV modules. Due to the coordinated switching of the dc-dc converters, each dc-dc converter transferring power to the common dc-bus continues to operate within its optimal efficiency range as well as to optimize the maximum power point tracking in order to increase the energy yield of the PV power plant.

Agamy, Mohammed; Elasser, Ahmed; Sabate, Juan Antonio; Galbraith, Anthony William; Harfman Todorovic, Maja

2014-09-09T23:59:59.000Z

98

Book Review: Etkind, Alexander, Rory Finnen et al. Remembering Katyn. Cambridge, UK and Malden, MA: Polity Press, 2012.  

E-Print Network (OSTI)

had on Poland, Russia, Ukraine, the Baltic states and in theevent had on neighbor- ing Ukraine and the Baltic states,

Kreuzberger, Thomas

2014-01-01T23:59:59.000Z

99

Professor Emeritus of Nuclear Science and Engineering Massachusetts Institute of Technology, Cambridge, MA 02139 (USA), syip@mit.edu  

E-Print Network (OSTI)

CV SIDNEY YIP Professor Emeritus of Nuclear Science and Engineering Massachusetts Institute.S. (Nuclear Engineering, 1959), and Ph.D. (Nuclear Engineering, 1962), all from the University of Michigan Professor (1965-69), Department of Nuclear Engineering, MIT, Research Associate (1963-65, Cornell University

Chen, Sow-Hsin

100

MA 232 Exam 1 (Green) Spring 2014  

E-Print Network (OSTI)

MA 23200 - Exam 1 (Green). 1. Find the area of the .... D. 4. E. Does not exist. 12. The velocity of a car over the time period 0 ? t ? 3 is given by the function.

2014-02-03T23:59:59.000Z

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

MA 16020 SI slide.pptx  

E-Print Network (OSTI)

SI Study Sessions for MA 16020 -? Spring 2015. Mondays. 4:30 5:20 KRCH 464. Tuesdays. 5:30 6:20 RHPH 162. Thursdays. 4:30 5:20 ARMS 1103.

OwenDavis

2015-01-12T23:59:59.000Z

102

DOE - Office of Legacy Management -- Watertown Arsenal - MA 02  

Office of Legacy Management (LM)

Watertown Arsenal - MA 02 Watertown Arsenal - MA 02 FUSRAP Considered Sites Site: WATERTOWN ARSENAL (MA.02 ) Eliminated from consideration under FUSRAP - Referred to EPA, State of Massachusetts, and the NRC Designated Name: Not Designated Alternate Name: None Location: Building Site 421 , Watertown , Massachusetts MA.02-1 Evaluation Year: 1985 MA.02-2 MA.02-3 Site Operations: Building 421 was used in the late 1940's and early 1950's by M.I.T. under Contract #AT (30-1)-956 for work on African Ores, and a modified ion-exchange technique was developed. Activities at Buildings 34, 41 and the GSA Site were conducted under AEC licensed. MA.02-4 MA.02-5 MA.02-6 Site Disposition: Eliminated - No Authority MA.02-6 MA.02-7 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Uranium MA.02-4

103

High efficiency resonant dc/dc converter for solar power applications .  

E-Print Network (OSTI)

??This thesis presents a new topology for a high efficiency dc/dc resonant power converter that utilizes a resistance compression network to provide simultaneous zero voltage (more)

Inam, Wardah

2013-01-01T23:59:59.000Z

104

DC systems with transformerless converters  

SciTech Connect

A technical and economic feasibility study of HVDC systems without converter transformers is presented. The presentation includes proposed solutions to the drawback related to the absence of galvanic separation between the ac and dc systems, if the converter transformers are eliminated. The results show that HVDC systems without converter transformers are both technically and economically feasible. The cost savings can be substantial.

Vithayathil, J.J.; Mittlestadt, W. [Bonneville Power Administration, Portland, OR (United States)] [Bonneville Power Administration, Portland, OR (United States); Bjoerklund, P.E. [ABB Power Systems AB, Ludvika (Sweden)] [ABB Power Systems AB, Ludvika (Sweden)

1995-07-01T23:59:59.000Z

105

DOE - Office of Legacy Management -- Woburn Landfill - MA 07  

Office of Legacy Management (LM)

Woburn Landfill - MA 07 FUSRAP Considered Sites Site: Woburn Landfill (MA.07) Eliminated from further consideration under FUSRAP Designated Name: Not Designated Alternate Name:...

106

Laser and Particle Beams http://journals.cambridge.org/LPB  

E-Print Network (OSTI)

Laser and Particle Beams http://journals.cambridge.org/LPB Additional services for Laser, J. Limpouch, R. Liska and P. Váchal Laser and Particle Beams / Volume 30 / Issue 03 / September 2012 of annularlaserbeamdriven plasma jets from massive planar targets. Laser and Particle Beams,30, pp 445457 doi:10.1017/S

Liska, Richard

107

www.cambridge.org/us/9780521194280 Molecular Machines in  

E-Print Network (OSTI)

www.cambridge.org/us/9780521194280 Molecular Machines in Biology Workshop of the Cell Joachim Frank Columbia University, New York About the Book The concept of molecular machines in biology has transformed, translation, protein folding, and protein degradation, are all carried out by molecular machines. This volume

Grishok, Alla

108

The Cambridge University Multimedia Document Retrieval Demo System  

E-Print Network (OSTI)

The Cambridge University Multimedia Document Retrieval Demo System A.Tuerk , S.E. Johnson , P University Multimedia Document Retrieval Demo System is a web based application that allows the user to query on text documents of various formats (e.g. html). Since there is an increasing amount of audio data

Drummond, Tom

109

The Cambridge University Multimedia Document Retrieval Demo System  

E-Print Network (OSTI)

The Cambridge University Multimedia Document Retrieval Demo System A.Tuerk y , S.E. Johnson y , P Multimedia Document Retrieval Demo System is a web based application that allows the user to query a database documents of various formats (e.g. html). Since there is an increasing amount of audio data containing

Drummond, Tom

110

http://journals.cambridge.org/ROB Additional services for Robotica  

E-Print Network (OSTI)

Robotica http://journals.cambridge.org/ROB Additional services for Robotica: Email alerts: Click predictive controller for robots to follow a virtual leader Dongbing Gu and Huosheng Hu Robotica / Volume 27. Robotica, 27, pp 905-913 doi:10.1017/S0263574708005316 Request Permissions : Click here Downloaded from

Hu, Huosheng

111

http://journals.cambridge.org/ROB Additional services for Robotica  

E-Print Network (OSTI)

Robotica http://journals.cambridge.org/ROB Additional services for Robotica: Email alerts: Click and Vicente Matellán Robotica / Volume 26 / Issue 06 / November 2008, pp 817 - 830 DOI: 10.1017/S (2008). A hybrid approach to fast and accurate localization for legged robots. Robotica, 26, pp 817

Hu, Huosheng

112

http://journals.cambridge.org/ROB Additional services for Robotica  

E-Print Network (OSTI)

Robotica http://journals.cambridge.org/ROB Additional services for Robotica: Email alerts: Click and Y. Ahmet ekerciolu Robotica / FirstView Article / October 2014, pp 1 - 13 DOI: 10.1017/S formation control of networked mobile robots in environments with obstacles. Robotica, Available on CJO 2014

Sekercioglu, Y. Ahmet

113

http://journals.cambridge.org/ROB Additional services for Robotica  

E-Print Network (OSTI)

Robotica http://journals.cambridge.org/ROB Additional services for Robotica: Email alerts: Click. Goldberg Robotica / Volume 13 / Issue 06 / November 1995, pp 565 573 DOI: 10.1017/S0263574700018646 algorithms for automatic planning by robots in stochastic environments. Robotica,13, pp 565573 doi:10.1017/S

Goldberg, Ken

114

http://journals.cambridge.org/ROB Additional services for Robotica  

E-Print Network (OSTI)

Robotica http://journals.cambridge.org/ROB Additional services for Robotica: Email alerts: Click Robotica / FirstView Article / September 2012, pp 1 8 DOI: 10.1017/S0263574711000774, Published online: 25 on taskoriented workspace. Robotica, Available on CJO 2011 doi:10.1017/S0263574711000774 Request Permissions

Kim, Jongwon

115

http://journals.cambridge.org/ROB Additional services for Robotica  

E-Print Network (OSTI)

Robotica http://journals.cambridge.org/ROB Additional services for Robotica: Email alerts: Click Robotica / Volume 24 / Issue 04 / July 2006, pp 429 - 431 DOI: 10.1017/S0263574705002420, Published online positioning method for a humanoid robot. Robotica, 24, pp 429-431 doi:10.1017/S0263574705002420 Request

Hu, Huosheng

116

NASA DC-8 Airborne Scanning Lidar System  

Science Journals Connector (OSTI)

A scanning lidar system is being developed for installation on the NASA DC-8 atmospheric research aircraft to support...in-situ aerosol and gas measurements. Design and objectives of the DC-8 scanning lidar are p...

Norman B. Nielsen; Edward E. Uthe

1997-01-01T23:59:59.000Z

117

ARM - Campaign Instrument - dc8-nasa  

NLE Websites -- All DOE Office Websites (Extended Search)

govInstrumentsdc8-nasa Comments? We would love to hear from you Send us a note below or call us at 1-888-ARM-DATA. Send Campaign Instrument : NASA DC-8 (DC8-NASA) Instrument...

118

DOE - Office of Legacy Management -- Tracerlab Inc - MA 11  

Office of Legacy Management (LM)

Tracerlab Inc - MA 11 Tracerlab Inc - MA 11 FUSRAP Considered Sites Site: TRACERLAB, INC. (MA.11 ) Eliminated from further consideration under FUSRAP Designated Name: Not Designated Alternate Name: None Location: 130 High Street , Boston , Massachusetts MA.11-1 Evaluation Year: 1987 MA.11-3 Site Operations: Research and development regarding uranium irradiation and cesium blocks during the early 1950s. MA.11-1 MA.11-3 Site Disposition: Eliminated - NRC licensed MA.11-2 MA.11-3 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Uranium, Cesium MA.11-1 Radiological Survey(s): None Indicated Site Status: Eliminated from further consideration under FUSRAP Also see Documents Related to TRACERLAB, INC. MA.11-1 - Tracerlab Letter; Epple to Mason; Subject: Steps to Secure

119

DC-DC converter current source fed naturally commutated brushless DC motor drive  

E-Print Network (OSTI)

, thereby generating switching losses and entail the use of large heatsinks. VSI needs a huge dc link capacitor that is inherently unreliable and is one of the most expensive components of a drive. Hence, a Current Source Inverter (CSI) is used to replace...

Khopkar, Rahul Vijaykumar

2004-11-15T23:59:59.000Z

120

Catalog of DC Appliances and Power Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

Catalog of DC Appliances and Power Systems Catalog of DC Appliances and Power Systems Title Catalog of DC Appliances and Power Systems Publication Type Report LBNL Report Number LBNL-5364E Year of Publication 2011 Authors Garbesi, Karina, Vagelis Vossos, and Hongxia Shen Document Number LBNL-5364E Date Published October Publisher Lawrence Berkeley National Laboratory Abstract This document catalogs the characteristics of current and potential future direct current (DC) products and power systems. It is part of a larger U.S. Department of Energy-funded project, "Direct-DC Power Systems for Energy Efficiency and Renewable Energy Integration with a Residential and Small Commercial Focus". That project is investigating the energy-savings potential, benefits, and barriers of using DC generated by on-site renewable energy systems directly in its DC form, rather than converting it first to alternating current (AC) for distribution to loads. Two related reports resulted from this work: this Catalog and a companion report that addresses direct-DC energy savings in U.S. residential buildings.Interest in 'direct-DC' is motivated by a combination of factors: the very rapid increase in residential and commercial photovoltaic (PV) power systems in the United States; the rapid expansion in the current and expected future use of energy efficient products that utilize DC power internally; the demonstrated energy savings of direct-DC in commercial data centers; and the current emergence of direct-DC power standards and products designed for grid-connected residential and commercial products. Based on an in-depth study of DC appliances and power systems, we assessed off-grid markets for DC appliances, the DC compatibility of mainstream electricity end-uses, and the emerging mainstream market for direct-DC appliances and power systems.

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Ecological benefits of dc power transmission  

SciTech Connect

The environmental effects of dc overhead transmission lines are examined. The major effects of ac and dc transmission lines are compared. Dc lines have advantages compared to ac lines in terms of electrical safety for people under the lines, biological effects, corona losses, and clearance width.

Kutuzova, N. B. [JSC 'NIIPT' (Russian Federation)

2011-05-15T23:59:59.000Z

122

Design and development of a DC-DC converter for a fuel cell inverter system  

E-Print Network (OSTI)

This thesis outlines the design and development of a DC-DC converter for a fuel cell inverter application. The proposed DC-DC converter was designed and tested at Texas A&M to meet the specifications laid down for the '2001 Future Energy Challenge...

Gopinath, Rajesh

2001-01-01T23:59:59.000Z

123

DOE - Office of Legacy Management -- National Fireworks Ordnance Corp - MA  

Office of Legacy Management (LM)

Fireworks Ordnance Corp - Fireworks Ordnance Corp - MA 13 FUSRAP Considered Sites Site: NATIONAL FIREWORKS ORDNANCE CORP (MA.13) Eliminated from consideration under FUSRAP Designated Name: Not Designated Alternate Name: American Potash and Chemical Corporation MA.13-3 Location: West Hanover , Massachusetts MA.13-1 Evaluation Year: 1991 MA.13-1 Site Operations: Performed bench scale research and development on uranium forming during the 1960s. MA.13-2 MA.13-3 Site Disposition: Eliminated - Potential for contamination considered remote based on the limited quantity of materials handled MA.13-1 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Uranium Metal and Powders MA.13-3 Radiological Survey(s): None Indicated MA.13-2 Site Status: Eliminated from consideration under FUSRAP

124

DOE - Office of Legacy Management -- Fenwal Inc - MA 14  

Office of Legacy Management (LM)

Fenwal Inc - MA 14 Fenwal Inc - MA 14 FUSRAP Considered Sites Site: Fenwal, Inc. (MA.14 ) Eliminated from consideration under FUSRAP Designated Name: Not Designated Alternate Name: None Location: Ashland , Massachusetts MA.14-1 Evaluation Year: 1994 MA.14-2 MA.14-3 Site Operations: Performed pilot scale explosion suppression tests on uranium contaminated magnesium fluoride powder in the late 1960s. MA.14-1 MA.14-3 Site Disposition: Eliminated - Potential for contamination considered remote based on the limited quantity of materials handled MA.14-2 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Uranium MA.14-1 Radiological Survey(s): None Indicated Site Status: Eliminated from consideration under FUSRAP Also see Documents Related to Fenwal, Inc.

125

Fabrication technology for ODS Alloy MA957  

SciTech Connect

A successful fabrication schedule has been developed at Carpenter Technology Corporation for the production of MA957 fuel and blanket cladding. Difficulties with gun drilling, plug drawing and recrystallization were overcome to produce a pilot lot of tubing. This report documents the fabrication efforts of two qualified vendors and the support studies performed at WHC to develop the fabrication-schedule.

ML Hamilton; DS Gelles; RJ Lobsinger; MM Paxton; WF Brown

2000-03-16T23:59:59.000Z

126

Ma, Dong and Gress QUARTERLY PROGRESS REPORT  

E-Print Network (OSTI)

and Leachability of Coal Combustion Residues in Florida Principal investigator: Lena Q. Ma- Environmental soil of this study is to determine the physical and chemical characteristics of coal combustion residues (CCR chemistry (Professor) Affiliation: Soil and Water Science Department, UF, Gainesville, FL 32611 Associate

Ma, Lena

127

Grid Security: Expecting the Mingchao Ma  

E-Print Network (OSTI)

Grid Security: Expecting the Unexpected Mingchao Ma STFC � Rutherford Appleton Laboratory, UK #12;Slide 2 Overview � Security Service Challenges (SSC) Review � Grid Security Incident � What had happened of the LCG/EGEE Grid Sites (Dec 2008) http://www.gridpp.ac.uk/security/ssc/ https

University College London

128

City of Cambridge, Nebraska (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Cambridge Cambridge Place Nebraska Utility Id 2888 Utility Location Yes Ownership M NERC Location MRO NERC MRO Yes Operates Generating Plant Yes Activity Generation Yes Activity Buying Transmission Yes Activity Distribution Yes Activity Wholesale Marketing Yes Activity Retail Marketing Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Commercial Commercial- All Electric Commercial Commercial- Demand Commercial Industrial Industrial Residential Residential Residential- All Electric Residential Three Phase Service Commercial Three Phase- All Electric Commercial

129

Performance Study of K2CsSb Photocathode Inside a DC High Voltage Gun  

SciTech Connect

In the past decade, there has been considerable interest in the generation of tens of mA average current in a photoinjector. Until recently, GaAs:Cs cathodes and K{sub 2}CsSb cathodes have been tested successfully in DC and RF injectors respectively for this application. Our goal is to test the K{sub 2}CsSb photocathode inside a DC gun. Since the multialkali cathode is a compound with constant characteristics over its entire thickness, we anticipate that the lifetime issues seen in GaAs:Cs due to surface damage by ion bombardment would be minimized. Hence successful operation of the K{sub 2}CsSb cathode in a DC gun could lead to a relatively robust electron source capable of delivering ampere level currents. In order to test the performance of a K{sub 2}CsSb cathode in a DC gun, we have designed and built a load lock system that allows the fabrication of the cathode at Brookhaven National Lab (BNL) and its testing at Jefferson Lab (JLab). In this paper, we will present the performance of the K{sub 2}CsSb photocathode in the preparation chamber and in the DC gun.

McCarter J. L.; Rao T.; Smedley, J.; Grames, J.; Mammei, R.; Poelker, M.; Suleiman, R.

2011-09-01T23:59:59.000Z

130

Performance Study of K2CsSb Photocathode inside a DC High Voltage Gun  

SciTech Connect

In the past decade, there has been considerable interest in the generation of tens of mA average current in a photoinjector. Until recently, GaAs:Cs cathodes and K2CsSb cathodes have been tested successfully in DC and RF injectors respectively for this application. Our goal is to test the GaAs:Cs in RF injector and the K2CsSb cathode in the DC gun in order to widen our choices. Since the multialkali cathode is a compound with uniform stochiometry over its entire thickness, we anticipate that the life time issues seen in GaAs:Cs due surface damage by ion bombardment would be minimized with this material. Hence successful operation of the K2CsSb cathode in DC gun could lead to a relatively robust electron source capable of delivering ampere level currents. In order to test the performance of K2CsSb cathode in a DC gun, we have designed and built a load lock system that would allow the fabrication of the cathode at BNL and its testing at JLab. In this paper, we will present the design of the load-lock system, cathode fabrication, and the cathode performance in the preparation chamber and in the DC gun.

T. Rao, J. Smedley, J.M. Grames, R. Mammei, J.L. McCarter, M. Poelker, R. Suleiman

2011-03-01T23:59:59.000Z

131

The Cambridge University Multimedia Document Retrieval Demo System  

E-Print Network (OSTI)

The Cambridge University Multimedia Document Retrieval Demo System A.Tuerky, S.E. Johnsony, P:==svr-www.eng.cam.ac.uk=research=projects=Multimedia Document Retrieval 1 System Description The CU-MDR Demo [3] is a web based application that allows the user-line. The system downloads the audio track of British and American news broadcasts from the Internet once a day

Drummond, Tom

132

The Cambridge University Multimedia Document Retrieval Demo System  

E-Print Network (OSTI)

The Cambridge University Multimedia Document Retrieval Demo System A.Tuerk, S.E. Johnson, P://svr-www.eng.cam.ac.uk/research/projects/Multimedia Document Retrieval 1 System Description The CU-MDR Demo [3] is a web based application that allows the user-line. The system downloads the audio track of British and American news broadcasts from the Internet once a day

Drummond, Tom

133

DC Distribution: The Power To Change Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

DC Distribution: The Power To Change Buildings DC Distribution: The Power To Change Buildings Speaker(s): Brian Patterson Dennis Symanski Liang Downey Date: July 14, 2011 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Chris Marnay This seminar presents an overview of the effort to create new applications standards to drive the distribution and use of native direct current (dc) in net zero energy commercial and residential buildings. From the early days of electric power generation, distribution and use there's been a debate over which form of power, AC or DC, is best. Edison set the stage for this argument in the late 1800's with his invention of DC powered lighting systems. Tesla's system of AC dynamos, transformers and motors all but stopped the growing use of DC by the turn of the century. With the

134

Map Locating Berkeley Lab Washington, DC Office  

NLE Websites -- All DOE Office Websites (Extended Search)

WASHINGTON, DC PROJECTS OFFICE WASHINGTON, DC PROJECTS OFFICE Map LEGEND: A:Berkeley Lab DC Office; PNNL; NREL; ORNL | B: EPA Waterside Mall C: Metrorail Station: Smithsonian | D: Metrorail Station: L'Enfant Plaza Notice: Due to security requirements in the building, all visitors to the Berkeley Lab DC Projects Office must check in at the ground floor entrance. If you do not have a DOE access badge, you will need to obtain a building visitor badge. To expedite this process, visitors are encouraged to RSVP to their meeting host or call (202) 488-2250 ahead of time. Metal detectors and x-ray screening of personal items are required for all visitors and staff entering the building. Directions to the Lab's Washington, DC Projects Office 901 D Street, SW Suite 950 Washington, DC 20024 Phone/Fax: (202) 488-2250

135

Active dc filter for HVDC systems  

SciTech Connect

This article is a case history of the installation of active dc filters for high-performance, low-cost harmonics filtering at the Lindome converter station in the Konti-Skan 2 HVDC transmission link between Denmark and Sweden. The topics of the article include harmonics, interference, and filters, Lindome active dc filter, active dc filter design, digital signal processor, control scheme, protection and fault monitoring, and future applications.

Zhang, W. (Royal Inst. of Tech., Stockholm (Sweden)); Asplund, G.

1994-01-01T23:59:59.000Z

136

A Fuel-Based Inventory for Heavy-Duty Diesel Truck Emissions  

E-Print Network (OSTI)

and Health Effects; Health Effects Institute: Cambridge, MA,and Health Effects; Health Effects Institute: Cambridge, MA,

Dreher, David B.; Harley, Robert A.

1998-01-01T23:59:59.000Z

137

26 Tesla DC Magnet for Neutron Scattering  

NLE Websites -- All DOE Office Websites (Extended Search)

Previously, DC Magnets located at Neutron-Scattering Beamlines were commercially-manufactured superconducting magnets and limited to 17 T. A few pulsed magnet systems have been...

138

Glass Ceramic Dielectrics for DC Bus Capacitors  

Energy.gov (U.S. Department of Energy (DOE))

2010 DOE Vehicle Technologies and Hydrogen Programs Annual Merit Review and Peer Evaluation Meeting, June 7-11, 2010 -- Washington D.C.

139

Reliability Assessment of Fault-Tolerant Dc-Dc Converters for Photovoltaic Applications  

E-Print Network (OSTI)

Reliability Assessment of Fault-Tolerant Dc-Dc Converters for Photovoltaic Applications Sairaj V in photovoltaic energy processing applications is presented. The proposed approach acknowledges the influence through several case studies. Index Terms-- Markov reliability modeling, photovoltaic systems, power

Liberzon, Daniel

140

Radio frequency dc-dc converters : device characterization, topology evaluation, and design  

E-Print Network (OSTI)

High frequency power conversion is attractive for the opportunities it affords for improved performance. Dc-dc converters operating at high frequencies use smaller-valued energy storage elements, which tend to be physically ...

Leitermann, Olivia

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

DC to DC power conversion module for the all-electric ship  

E-Print Network (OSTI)

The MIT end to end electric ship model is being developed to study competing electric ship designs. This project produced a model of a Power Conversion Module (PCM)- 4, DC-to-DC converter which interfaces with the MIT ...

Gray, Weston L

2011-01-01T23:59:59.000Z

142

DOE - Office of Legacy Management -- Manufacturing Laboratories Inc - MA  

Office of Legacy Management (LM)

Manufacturing Laboratories Inc - MA Manufacturing Laboratories Inc - MA 0-04 FUSRAP Considered Sites Site: MANUFACTURING LABORATORIES, INC. (MA.0-04 ) Eliminated from further consideration under FUSRAP Designated Name: Not Designated Alternate Name: None Location: 272 Northampton Street , Boston , Massachusetts MA.0-04-1 Evaluation Year: 1987 MA.0-04-3 Site Operations: Developed a process for making projectiles from depleted uranium during the early 1950s. MA.0-04-3 Site Disposition: Eliminated - Potential for contamination considered remote based on limited scope of operations at the site MA.0-04-2 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Uranium MA.0-04-1 Radiological Survey(s): None Indicated Site Status: Eliminated from further consideration under FUSRAP

143

DOE - Office of Legacy Management -- Norton Co - MA 12  

Office of Legacy Management (LM)

the File; Subject: Elimination Recommendation; October 26, 1987 MA.12-4 - AEC Letter; White to Warde; Subject: Thorium Samples; February 19, 1954 MA.12-5 - AEC Memorandum; Morgan...

144

Supplementary Figure 1 SHAPE-MaP data analysis pipeline.  

E-Print Network (OSTI)

Supplementary Figure 1 SHAPE-MaP data analysis pipeline. Outline of software pipeline that fully.1 GHz Intel Core i7 and 16 GB RAM). This strategy is implemented in the SHAPE-MaP Folding Pipeline

Cai, Long

145

Washington, DC~ZO585  

Office of Legacy Management (LM)

jpfl.3%2' jpfl.3%2' ) .,Departhent of Eikrgj! : Washington, DC~ZO585 .-, , , Lf; I: ~.1,' .Yj4 , The Honorable Louis Barlup 55 ,E. Main Street Waynesboro;,Pennsy,lvania 17268 '~ Dear Mayor Barl,up:' Secretary of Energy Hazel O'Leary has'announced' a new approach to openness,in the Department of Energy-(DOE) and its communications with the public. In support-of this initiative, we are pleased.to forward the enclosed information related to the former Landis Machine Tool Co. site in your jurisdiction that performed work for DOE or its predecessor agencies. This information:is provided for your information< use, and retention. DOE's Formerly Utilized Sites Remedial Action Program is responsible for identification of sites used by DOE's predecessor agencies, determining their

146

High voltage DC power supply  

DOE Patents (OSTI)

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively. 7 figs.

Droege, T.F.

1989-12-19T23:59:59.000Z

147

High voltage DC power supply  

DOE Patents (OSTI)

A high voltage DC power supply having a first series resistor at the output for limiting current in the event of a short-circuited output, a second series resistor for sensing the magnitude of output current, and a voltage divider circuit for providing a source of feedback voltage for use in voltage regulation is disclosed. The voltage divider circuit is coupled to the second series resistor so as to compensate the feedback voltage for a voltage drop across the first series resistor. The power supply also includes a pulse-width modulated control circuit, having dual clock signals, which is responsive to both the feedback voltage and a command voltage, and also includes voltage and current measuring circuits responsive to the feedback voltage and the voltage developed across the second series resistor respectively.

Droege, Thomas F. (Batavia, IL)

1989-01-01T23:59:59.000Z

148

DOE - Office of Legacy Management -- Naval Research Laboratory - DC 02  

Office of Legacy Management (LM)

Research Laboratory - DC 02 Research Laboratory - DC 02 FUSRAP Considered Sites Site: NAVAL RESEARCH LABORATORY (DC.02 ) Eliminated from consideration under FUSRAP - Referred to DOD Designated Name: Not Designated Alternate Name: None Location: Washington , D.C. DC.02-4 Evaluation Year: 1987 DC.02-4 Site Operations: Research and development on thermal diffusion. DC.02-4 Site Disposition: Eliminated - No Authority - AEC licensed - Military facility DC.02-4 DC.02-1 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Uranium, Thorium DC.02-2 DC.02-3 Radiological Survey(s): None Indicated Site Status: Eliminated from consideration under FUSRAP - Referred to DOD DC.02-4 Also see Documents Related to NAVAL RESEARCH LABORATORY DC.02-1 - AEC Memorandum and Source Material License No. C-3393;

149

Morley Symposium on Concrete Plasticity and its Application. University of Cambridge 23 WHEN PLASTICITY?  

E-Print Network (OSTI)

, 2007 WHEN PLASTICITY? Chris MORLEY Department of Engineering, University of Cambridge, UK Keywords based on some form of plasticity theory, perhaps with modifications - with serviceability achievedMorley Symposium on Concrete Plasticity and its Application. University of Cambridge 23 rd July

Burgoyne, Chris

150

JJ, IAP Cambridge January 20101 Fusion Energy & ITER:Fusion Energy & ITER  

E-Print Network (OSTI)

Billions ITERITER startsstarts DEMODEMO decisiondecision:: Fusion impact? Energy without greenEnergyJJ, IAP Cambridge January 20101 Fusion Energy & ITER:Fusion Energy & ITER: Challenges without green house gashouse gas #12;JJ, IAP Cambridge January 20103 3 D + T + He ++ n U235 n n Neutrons

151

CSC 1051 M.A. Papalaskari, Villanova University Conditional Statements  

E-Print Network (OSTI)

CSC 1051 M.A. Papalaskari, Villanova University Conditional Statements Dr. Mary-Angela Papalaskari); } CSC 1051 M.A. Papalaskari, Villanova University A boolean expression Review if true, do this if more statement 1 true false statement2 CSC 1051 M.A. Papalaskari, Villanova University condition evaluated

Papalaskari, Mary-Angela

152

Economics & Finance MA or BSc (Single Honours Degrees)  

E-Print Network (OSTI)

88 Economics & Finance MA or BSc (Single Honours Degrees) Applied Economics Economics Financial Economics BA (International Honours Degrees) Economics See page 13 MA or BSc (Joint Honours Degrees) Economics and one of: Management Mathematics MA (Joint Honours Degrees) Economics and one of: Ancient

Brierley, Andrew

153

Data Update for Mt. Tom, Holyoke, MA Prepared for  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA July 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for July 2007 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

154

Data Update for Mt. Tom, Holyoke, MA February 2006  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA February 2006 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Melissa Ray Monthly Data Summary for February 2005 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

155

Data Update for Mt. Tom, Holyoke, MA January 2006  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA January 2006 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Melissa Ray Monthly Data Summary for December 2005 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

156

Data Update for Mt. Tom, Holyoke, MA February 2008  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA February 2008 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for February 2008 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

157

Data Update for Mt. Tom, Holyoke, MA January 2007  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA January 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for January 2007 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

158

Data Update for Mt. Tom, Holyoke, MA Prepared for  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA June 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for June 2007 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

159

Data Update for Mt. Tom, Holyoke, MA Prepared for  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA March 2008 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for March 2008 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

160

Data Update for Mt. Tom, Holyoke, MA August 2007  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA August 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for August 2007 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Data Update for Mt. Tom, Holyoke, MA Prepared for  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA April 2006 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Melissa Ray Monthly Data Summary for April 2006 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59.2" N, 72

Massachusetts at Amherst, University of

162

Data Update for Mt. Tom, Holyoke, MA Prepared for  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA March 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for March 2007 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

163

Data Update for Mt. Tom, Holyoke, MA February 2007  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA February 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for February 2007 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

164

Data Update for Mt. Tom, Holyoke, MA November 2007  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA November 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for November 2007 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

165

Data Update for Mt. Tom, Holyoke, MA September 2007  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA September 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for September 2007 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

166

Data Update for Mt. Tom, Holyoke, MA September 2005  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA September 2005 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Melissa Ray Monthly Data Summary for September 2005 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

167

Data Update for Mt. Tom, Holyoke, MA January 2008  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA January 2008 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for January 2008 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

168

Data Update for Mt. Tom, Holyoke, MA Prepared for  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA April 2008 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for April 2008 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

169

Data Update for Mt. Tom, Holyoke, MA October 2005  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA October 2005 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Melissa Ray Monthly Data Summary for October 2005 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

170

Data Update for Mt. Tom, Holyoke, MA Prepared for  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA March 2006 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Melissa Ray Monthly Data Summary for March 2006 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59.2" N, 72

Massachusetts at Amherst, University of

171

Data Update for Mt. Tom, Holyoke, MA Prepared for  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA May 2008 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for May 2008 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

172

Data Update for Mt. Tom, Holyoke, MA October 2007  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA October 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for October 2007 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

173

Data Update for Mt. Tom, Holyoke, MA Prepared for  

E-Print Network (OSTI)

Data Update for Mt. Tom, Holyoke, MA May 2007 Prepared for Massachusetts Technology Collaborative 75 North Drive, Westborough, MA 01581 By Puneet Malhotra Monthly Data Summary for May 2007 This update summarizes the monthly data results for the Mt. Tom monitoring site in Holyoke, MA, at 42° 14' 59

Massachusetts at Amherst, University of

174

Washington, DC | Building Energy Codes Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Washington, DC Washington, DC Last updated on 2013-08-02 Current News In December, the DC CCCB voted 7-1 to adopt the 2012 IECC. The code will now enter administrative review and legislative process with likely adoption in the second half of 2013. Commercial Residential Code Change Current Code ASHRAE Standard 90.1-2007 with Amendments Amendments / Additional State Code Information Based on 2008 DC Construction Code with several amendments. State Specific Research Impacts of ASHRAE 90.1-2007 for Commercial Buildings in the District of Columbia (BECP Report, Sept. 2009) Approximate Energy Efficiency Equivalent to ASHRAE 90.1-2007 Effective Date 12/26/2009 Adoption Date 12/26/2008 Code Enforcement Mandatory DOE Determination ASHRAE 90.1-2007: Yes ASHRAE 90.1-2010: No DC DOE Determination Letter, May 31, 2013

175

A Review of DC Micro-grid Protection  

Science Journals Connector (OSTI)

In this paper, an overview of DC micro-grid is described, which includes the status of DC micro-grid protection and its future development. The paper presents the key techniques of DC micro-grid protection. So fa...

Yuhong Xie; Jia Ning; Yanquan Huang

2013-01-01T23:59:59.000Z

176

El Ma Electronic Machining srl | Open Energy Information  

Open Energy Info (EERE)

Ma Electronic Machining srl Ma Electronic Machining srl Jump to: navigation, search Name El.Ma. Electronic Machining srl Place Riva del Garda (TN), Italy Zip 38066 Sector Hydro, Hydrogen, Solar, Wind energy Product String representation "Italy-based, in ... solar sectors." is too long. References El.Ma. Electronic Machining srl[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. El.Ma. Electronic Machining srl is a company located in Riva del Garda (TN), Italy . References ↑ "El.Ma. Electronic Machining srl" Retrieved from "http://en.openei.org/w/index.php?title=El_Ma_Electronic_Machining_srl&oldid=344591" Categories: Clean Energy Organizations Companies Organizations

177

Research on Energy Efficiency of DC Distribution System  

Science Journals Connector (OSTI)

Abstract Energy efficiency of DC distribution systems is researched in this paper. Efficiency calculation models of feeders and loads are established, efficiencies of AC/DC, DC/DC and DC/AC are analyzed. Moreover, energy efficiencies of an AC system and two DC systems, monopole and bipolar, are calculated and compared. The efficiency improvement of office building supplied by DC power system compared to supply by AC power system is demonstrated. From analysis, it is showed that the energy efficiency is higher in DC distribution system than AC distribution system.

Zifa Liu; Mengyu Li

2014-01-01T23:59:59.000Z

178

Corrosion of MA754 and MA956 in a Commercial Aluminum Melter  

SciTech Connect

The University of North Dakota Energy & Environmental Research Center is working with Oak Ridge National Laboratory to test two oxide dispersion-strengthened alloys that could be used to construct very high-temperature heat recuperators for the aluminum-melting industry. For the initial tests, uncooled rings of MA754 and MA956 piping were exposed for 5 months to gases leaving an aluminum melter furnace at 1200 1290 C. The MA956 suffered spotty areas of severe corrosion and lost 25% of its weight. Scanning electron microscopy showed that there were small spots of alkali-rich corrosion products on the alloy surfaces, indicating the impact of droplets of fluxing agents. The corrosion products in these areas were mixed Fe, Cr, and Al oxides, which were depleted in Cr near the gas surface. However, Al concentrations in the remaining metal were typically between 3.5% and 4.0%, so there was a sufficient reservoir of Al remaining in the alloy to prevent simple breakaway corrosion which could have occurred if the Al were significantly depleted. The MA754 lost approximately 15% of its weight and showed void formation within 2 mm of the gas metal surfaces. Within the porous area, the Cr had largely segregated into oxide precipitates up to 50 9m in diameter, leaving the remaining metal Ni-rich. Below the porous layer, the alloy composition was relatively unchanged. Remains of Na- and Al-rich particles that had impacted the surface sporadically were visible but had not obviously affected the surface scale as they had with the MA956.

Hurley, John P. [University of North Dakota Energy & Environmental Research Center] [University of North Dakota Energy & Environmental Research Center; Kelley, Carl [Natures Fuel, 410 East Cook Road, Fort Wayne, IN 46825, USA] [Natures Fuel, 410 East Cook Road, Fort Wayne, IN 46825, USA; Bornstein, Norman S. [Consultant] [Consultant; Wright, Ian G [ORNL] [ORNL

2008-01-01T23:59:59.000Z

179

News From the D.C. Office  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Aerial view of Washington D.C. 3 Aerial view of Washington D.C. News From the D.C. Office The federal government is the largest single purchaser in the world for many energy-related products. Federal buying power-along with that of state and local agencies-represents a largely untapped resource to increase the energy efficiency of consumer products and commercial equipment. LBL is helping the DOE Federal Energy Management Program (FEMP) develop and lead a government-wide initiative to capture this market-transforming opportunity. Jeff Harris and others in LBL's D.C. office are heading FEMP's efforts to identify how future federal purchases can be more energy-efficient. The U.S. government spends more than $70 billion a year to purchase supplies and equipment, of which an estimated $10-20 billion are energy-

180

D.C. | OpenEI Community  

Open Energy Info (EERE)

94 94 Varnish cache server Home Groups Community Central Green Button Applications Developer Utility Rate FRED: FRee Energy Database More Public Groups Private Groups Features Groups Blog posts Content Stream Documents Discussions Polls Q & A Events Notices My stuff Energy blogs 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation: XID: 2142234494 Varnish cache server D.C. Home Kyoung's picture Submitted by Kyoung(155) Contributor 6 September, 2012 - 08:51 GRR Update Meeting scheduled for 9/13 in D.C. D.C. GRR meeting update The next Geothermal Regulatory Roadmap update meeting will be held in Washington, D.C. on Thursday, September 13 from 2-4 p.m. Syndicate content 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load) Guru Meditation:

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

DC readout experiment in Enhanced LIGO  

E-Print Network (OSTI)

The two 4 km long gravitational wave detectors operated by the Laser Interferometer Gravitational-wave Observatory (LIGO) were modified in 2008 to read out the gravitational wave channel using the DC readout form of homodyne ...

Fricke, Tobin T

182

Sandia National Laboratories: DC power optimizers  

NLE Websites -- All DOE Office Websites (Extended Search)

DC power optimizers Sandia R&D Funded under New DOE SunShot Program On November 27, 2013, in Energy, News, News & Events, Partnership, Photovoltaic, Renewable Energy, Solar,...

183

Office of Informaiton Resources (MA-90)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

08 08 Melanie Pustay Director Office of Information and Privacy U.S. Department of Justice 1425 New York Ave., Suite 11050 Washington, DC 20530 Dear Ms. Pustay: Pursuant to the requirements set forth by Title 5, United States Code, Section 552(e), enclosed is a copy of the Annual Report on the administration of the Freedom of Information Act (FOIA) by the Department of Energy. The report will be made available on the World Wide Web through the FOIA Home Page of the Department. If you have any questions, please contact Mr. Chris Morris or Ms. Sheila Jeter of my staff at (202) 586-5955. Sincerely, yerlette L. aili in, Deputy Director FOIA and Privacy Act Office Office of Information Resources Enclosure @ Printed with soy ink on recycled paper U.S. Department of Energy

184

KwanliuMa_NERSC2011.ppt  

NLE Websites -- All DOE Office Websites (Extended Search)

Analysis and Visualization Analysis and Visualization Computing Requirements A Case Study Kwan-Liu Ma University of California, Davis SciDAC Institute for Ultrascale Visualization Outline * SciDAC Institute for Ultrascale Visualization * Visualization Solutions for Turbulent Combustion Simulations * A Case Study on Particle Trajectories Data Visualization Turbulent Combustion Simulations  Jackie Chen, Sandia National Laboratory  Direct numerical simulation tools are being developed Turbulent Combustion Simulations * High fidelity modeling is required to reliably predict efficiency and pollutant emission for new engines and new fuels * The current simulation code running on a supercomputer like the Cray XT5 uses up to 48,000 cores and over 14 million CPU hours per run

185

Recovery Act State Memos Washington, DC  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Washington, DC Washington, DC For questions about DOE's Recovery Act activities, please contact the DOE Recovery Act Clearinghouse: 1-888-DOE-RCVY (888-363-7289), Monday through Friday, 9 a.m. to 7 p.m. Eastern Time https://recoveryclearinghouse.energy.gov/contactUs.htm. All numbers and projects listed as of June 1, 2010 TABLE OF CONTENTS RECOVERY ACT SNAPSHOT................................................................................... 1 FUNDING ALLOCATION TABLE.............................................................................. 2 ENERGY EFFICIENCY ............................................................................................... 3 RENEWABLE ENERGY ............................................................................................. 5

186

oe oe oe oe oe Mi ye ma lel gvu  

E-Print Network (OSTI)

& & V ? c c c c Soprano Alto Tenor Bass q»¡¶ oe oe oe oe oe Mi ye ma lel gvu oe oe oe oe oe rot yis ra el o oe oe oe oe oe Mi ye ma lel o tan mi tan mi oe oe oe oe oe Mi ye ma lel o yim ne? yim ne tan mi oe oe oe oe oe Mi ye ma lel gvu w ah oe oe oe oe oe Hen be chol dor ya yim ne w rot

Setiawan, Hendra

187

Newton was born Christmas day 1642 Started in Cambridge 1661, BA early in 1665  

E-Print Network (OSTI)

Newton Newton was born Christmas day 1642 Started in Cambridge 1661, BA early in 1665 Successor of calculus, nature of light, and theory of gravitation. Work on mathematics largely unpublished. In 1666

Junge, Marius

188

See things differently as the people behind museums and collections in Cambridge share their favourite objects,  

E-Print Network (OSTI)

hints at the exotic, distant lands of childhood fairy stories ..." Sally Petitt, Head of Horticulture,CambridgeMuseumofTechnology "... one of the furnace doors is opened...releasing a burst of heat and light." John Connett, Steam

Steiner, Ullrich

189

E-Print Network 3.0 - air force cambridge Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Search Sample search results for: air force cambridge Page: << < 1 2 3 4 5 > >> 1 Air Pollution Physics and Chemistry EAS 6790 Monday, Wednesday, Friday 2:05 to 2:55...

190

DC's Marble ceiling : urban height and its regulation in Washington, DC  

E-Print Network (OSTI)

Washington, DC has a unique urban form that is the result of a century-old law. Through the narrow lens of DC's height limit, I survey a range of topics related to urban height, starting with a review of its history of ...

Trueblood, Andrew Tyson

2009-01-01T23:59:59.000Z

191

FC/Battery Power Management for Electric Vehicle Based Interleaved dc-dc Boost Converter Topology  

E-Print Network (OSTI)

FC/Battery Power Management for Electric Vehicle Based Interleaved dc- dc Boost Converter Topology power systems in electric vehicle application, in order to decrease the FC current ripple. Therefore the performance of the FC system during transient and instantaneous peak power demands in electric vehicle

Paris-Sud XI, Université de

192

Method to Improve Total Dose Radiation Hardness in a CMOS dc-dc Boost  

E-Print Network (OSTI)

in a wide range of radiation environment, with increasing total dose radiation, The efticieney also greatlyMethod to Improve Total Dose Radiation Hardness in a CMOS dc-dc Boost Converter Huadian Pan to natural radiation in space. Among the effects of ionizing radiation are shiftsin threshold voltageand

Wilamowski, Bogdan Maciej

193

5 kW Multilevel DC-DC Converter for Hybrid Electric and Fuel Cell Automotive  

E-Print Network (OSTI)

automobile, there are many electrical loads grouped into two main categories depending on the voltages5 kW Multilevel DC-DC Converter for Hybrid Electric and Fuel Cell Automotive Applications Faisal H. Khan1,2 Leon M. Tolbert2 fkhan3@utk.edu tolbert@utk.edu 1 Electric Power Research Institute (EPRI) 2

Tolbert, Leon M.

194

Pulsed dc self-sustained magnetron sputtering  

SciTech Connect

The magnetron sputtering has become one of the commonly used techniques for industrial deposition of thin films and coatings due to its simplicity and reliability. At standard magnetron sputtering conditions (argon pressure of {approx}0.5 Pa) inert gas particles (necessary to sustain discharge) are often entrapped in the deposited films. Inert gas contamination can be eliminated during the self-sustained magnetron sputtering (SSS) process, where the presence of the inert gas is not a necessary requirement. Moreover the SSS process that is possible due to the high degree of ionization of the sputtered material also gives a unique condition during the transport of sputtered particles to the substrate. So far it has been shown that the self-sustained mode of magnetron operation can be obtained using dc powering (dc-SSS) only. The main disadvantage of the dc-SSS process is its instability related to random arc formation. In such case the discharge has to be temporarily extinguished to prevent damaging both the magnetron source and power supply. The authors postulate that pulsed powering could protect the SSS process against arcs, similarly to reactive pulsed magnetron deposition processes of insulating thin films. To put this concept into practice, (i) the high enough plasma density has to be achieved and (ii) the type of pulsed powering has to be chosen taking plasma dynamics into account. In this article results of pulsed dc self-sustained magnetron sputtering (pulsed dc-SSS) are presented. The planar magnetron equipped with a 50 mm diameter and 6 mm thick copper target was used during the experiments. The maximum target power was about 11 kW, which corresponded to the target power density of {approx}560 W/cm{sup 2}. The magnetron operation was investigated as a function of pulse frequency (20-100 kHz) and pulse duty factor (50%-90%). The discharge (argon) extinction pressure level was determined for these conditions. The plasma emission spectra (400-410 nm range) and deposition rates were observed for both dc and pulsed dc self-sustained sputtering processes. The pulse characteristics of the voltage and current of the magnetron source during pulsed dc-SSS operation are shown. The presented results illustrate that a stable pulsed dc-SSS process can be obtained at a pulsing frequency in the range of 60-90 kHz and duty factor of 80%-90%.

Wiatrowski, A.; Posadowski, W. M.; Radzimski, Z. J. [Faculty of Microsystems, Electronics and Photonics, Wroclaw University of Technology, Janiszewskiego 11/17, 50-372 Wroclaw (Poland); Silicon Quest International, Santa Clara, California (United States)

2008-09-15T23:59:59.000Z

195

James Warren, Epicurus and Democritean Ethics, An Archaeology of Ataraxia. Cambridge: Cambridge University Press, 2002.241pp. $55.00 ISBN 0-521-81369-7  

E-Print Network (OSTI)

Book Reviews 69 James Warren, Epicurus and Democritean Ethics, An Archaeology of Ataraxia. Cambridge: Cambridge University Press, 2002.241pp. $55.00 ISBN 0-521-81369-7 LariyJ. Waggle Illinois State University Over the last twenty years... are the removal of fear, superstition, and the removal of anxiety in order to attain the telos. 5 LSJ sv. 6 Jeffry Purrington makes a similar remark in his article "Epicurus on the Telos", Phronesis 38. 1993. p. 281-321. 7 DL 9.61 8 Diogenes Laertius reports...

Waggle, Larry J.

196

J. Michael Starling, M.A. Department of Educational Psychology  

E-Print Network (OSTI)

J. Michael Starling, M.A. Department of Educational Psychology Ball State University Muncie.D. Ball State University 2014 (Expected) Educational Psychology (General) Cognate: Research Methodology M.A. Ball State University 2009 School Psychology B.A. Anderson University 2008 Psychology Graduate

Wu, Mingshen

197

FRACTIONAL SKEW MONOID RINGS P. ARA, M.A. GONZ  

E-Print Network (OSTI)

FRACTIONAL SKEW MONOID RINGS P. ARA, M.A. GONZ ?? ALEZ­BARROSO, K.R. GOODEARL, AND E. PARDO FQM­298 of the Junta de Andaluc??�a. 1 #12; 2 P. ARA, M.A. GONZ ?? ALEZ­BARROSO, K.R. GOODEARL, AND E

Bigelow, Stephen

198

Good Energies (Washington DC) | Open Energy Information  

Open Energy Info (EERE)

Energies (Washington DC) Energies (Washington DC) Name Good Energies (Washington DC) Address 1250 24th St., NW, Suite 250 Place Washington, District of Columbia Zip 20037 Product Global investor in renewable energy and energy efficiency industries Year founded 2001 Phone number (202) 747-2550 Website http://www.goodenergies.com/ Coordinates 38.90649°, -77.051534° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.90649,"lon":-77.051534,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

199

New Experimental Data in DC745U  

SciTech Connect

The objectives of this project are: (1) study the molecular and mechanical properties of DC745U - (a) DC745U is a silicone elastomer used in several weapons systems, (b) depending on their chemistry and formulation, polymers can be susceptible to damage and failures due to weak chemical linkages and physical interactions, (c) inefficient production processes can generate heterogeneities throughout the material that can contribute negatively to the overall performance and lifetime of the polyer, (d) aging, long-term thermal and radioactive conditions, and mechanical strains can affect the materials network structure and contribute to the degradation of the production; (2) characterization of DC745U materials cured under different conditions to determine possible differences to the polymer structure; and (3) this work is relevant to mission-critical programs and for supporting programmatic work for weapon research.

Ortiz-Acosta, Denisse [Los Alamos National Laboratory; Cady, Carl [Los Alamos National Laboratory; Densmore, Crystal [Los Alamos National Laboratory

2012-06-18T23:59:59.000Z

200

DC transformer for DC/DC connection in HVDC network M. Jimenez Carrizosa1, A. Benchaib2, P. Alou3, G. Damm4  

E-Print Network (OSTI)

DC transformer for DC/DC connection in HVDC network M. Jim´enez Carrizosa1, A. Benchaib2, P. Alou3>>, >, HVDC>>, > . Abstract This paper presents the modeling and control for the integration of an offshore wind farm in a High Voltage Direct Current (HVDC). Until developed of VSC (voltage

Paris-Sud XI, Université de

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

(1) Biology Department, Woods Hole Oceanographic Institution, Woods Hole, MA 02543 USA(1) Biology Department, Woods Hole Oceanographic Institution, Woods Hole, MA 02543 USA (2) Harvard Medical School, Boston, MA 02114 USA(2) Harvard Medical School, Boston  

E-Print Network (OSTI)

(1) Biology Department, Woods Hole Oceanographic Institution, Woods Hole, MA 02543 USA(1) Biology Department, Woods Hole Oceanographic Institution, Woods Hole, MA 02543 USA (2) Harvard Medical School, Boston, MA 02114 USA(2) Harvard Medical School, Boston, MA 02114 USA (3) Section on Auditory Mechanics, NIDCD

202

Perseus LLC (Washington DC) | Open Energy Information  

Open Energy Info (EERE)

DC) DC) Jump to: navigation, search Logo: Perseus LLC (Washington DC) Name Perseus LLC (Washington DC) Address 2099 Pennsylvania Avenue, N.W., 9th Floor Place Washington, District of Columbia Zip 20006 Product Private equity fund Year founded 1995 Phone number (202) 452-0101 Website http://www.perseusllc.com/ Coordinates 38.901462°, -77.046347° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.901462,"lon":-77.046347,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

203

FEDERAL ENERGY WASHINGTON, D.C. 20426  

E-Print Network (OSTI)

FEDERAL ENERGY REGULATORY COMMISSION WASHINGTON, D.C. 20426 NEWS RELEASE NEWS MEDIA CONTACT judge, the Federal Energy Regulatory Commission today ordered an expedited fact-finding hearing of the discussions. #12;Chairman Curt L. Hébert, Jr. stated as follows: "At some point, regulatory and R-01-33 (more

Laughlin, Robert B.

204

Halbach array DC motor/generator  

DOE Patents (OSTI)

A new configuration of DC motor/generator is based on a Halbach array of permanent magnets. This motor does not use ferrous materials so that the only losses are winding losses and losses due to bearings and windage. An "inside-out" design is used as compared to a conventional motor/generator design. The rotating portion, i.e., the rotor, is on the outside of the machine. The stationary portion, i.e., the stator, is formed by the inside of the machine. The rotor contains an array of permanent magnets that provide a uniform field. The windings of the motor are placed in or on the stator. The stator windings are then "switched" or "commutated" to provide a DC motor/generator much the same as in a conventional DC motor. The commutation can be performed by mechanical means using brushes or by electronic means using switching circuits. The invention is useful in electric vehicles and adjustable speed DC drives.

Merritt, Bernard T. (Livermore, CA); Dreifuerst, Gary R. (Livermore, CA); Post, Richard F. (Walnut Creek, CA)

1998-01-01T23:59:59.000Z

205

A Three-Phase Bidirectional DC-DC Converter for Automotive Applications  

SciTech Connect

This paper presents a three-phase soft-switching, bidirectional dc-dc converter for high-power automotive applications. The converter employs dual three-phase active bridges and operates with a novel asymmetrical but fixed duty cycle for the top and bottom switches of each phase leg. Simulation and experimental data on a 6-kW prototype are included to verify the novel operating and power flow control principles.

Su, Gui-Jia [ORNL; Tang, Lixin [ORNL

2008-01-01T23:59:59.000Z

206

Federal Government Congressional Budget Office, Budget Analysis Division Washington, DC  

E-Print Network (OSTI)

Administration, Center for Drug Evaluation and Research Washington, DC Federal Energy Regulatory CommissionFederal Government Congressional Budget Office, Budget Analysis Division Washington, DC Department Environmental Protection Agency, Office of Transportation & Air Quality Ann Arbor, MI Federal Drug

Shyy, Wei

207

National Small Business Federal Contracting Summit-DC Fall Conference...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

National Small Business Federal Contracting Summit-DC Fall Conference National Small Business Federal Contracting Summit-DC Fall Conference November 6, 2014 8:00AM to 4:00PM EST...

208

DC High School Science Bowl Regionals | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DC High School Science Bowl Regionals DC High School Science Bowl Regionals February 22, 2014 1:15PM to 8:15PM EST Department of Energy headquarters - 1000 Independence Ave SW,...

209

http://journals.cambridge.org Downloaded: 16 Dec 2008 IP address: 128.118.145.89 Of mice and men: asymmetric interactions between  

E-Print Network (OSTI)

. BJORNSTAD4,5 and E. T. HARVILL2 1 Cambridge Infectious Diseases Consortium, Department of Veterinary

210

Universit Paris Descartes -UFR STAPS -Planning 2013-2014 (proposition 1B2) Arts Thrapies D 1 Ma 1 V 1 D 1 Me 1 S 1 S 1 Ma 1 J 1 D 1 Ma 1  

E-Print Network (OSTI)

Université Paris Descartes - UFR STAPS - Planning 2013-2014 (proposition 1B2) Arts Thérapies D 1 Ma 1 V 1 D 1 Me 1 S 1 S 1 Ma 1 J 1 D 1 Ma 1 L 2 Me 2 S 2 L 2 J 2 D 2 D 2 Me 2 V 2 L 2 Me 2 Ma 3 J 3 D 3 Ma 3 V 3 L 3 L 3 J 3 S 3 Ma 3 J 3 Me 4 V 4 L 4 Me 4 S 4 Ma 4 Ma 4 V 4 D 4 Me 4 V 4 J 5 S 5 Ma 5 J 5 D

Pellier, Damien

211

Johnston LFG (MA RPS Biomass Facility | Open Energy Information  

Open Energy Info (EERE)

LFG (MA RPS Biomass Facility LFG (MA RPS Biomass Facility Jump to: navigation, search Name Johnston LFG (MA RPS Biomass Facility Facility Johnston LFG (MA RPS Sector Biomass Facility Type Landfill Gas Location Rhode Island Coordinates 41.5800945°, -71.4774291° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.5800945,"lon":-71.4774291,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

212

Telecommunications Concentration: Grady College MA Thesis Program Planning Form  

E-Print Network (OSTI)

Telecommunications Concentration: Grady College MA Thesis Program Planning Form Student: Advisor ( ) Telecommunication Policy JRMC 8220 ( ) Telecommunications Programming and Criticism JRMC 8230 ( ) Emerging Telecommunication Technologies JRMC 8240 ( ) Special Topics in Telecommunications JRMC 8365 ( ) Media Economics JRMC

Arnold, Jonathan

213

Index of /~arshak/F04/MA266/matlab  

E-Print Network (OSTI)

Index of /~arshak/F04/MA266/matlab. [ICO], Name Last modified Size Description. [DIR], Parent Directory, -. [ ], func1.m, 21-Sep-2004 23:46, 39. [ ], func2.

214

MaJIC: A Matlab Just-In-Time Compiler  

Science Journals Connector (OSTI)

This paper describes our experience with MaJIC, a just-intime compiler for MATLAB. In the recent past, several compiler projects claimed large performance improvements when processing MATLAB code. Most of these projects

George Almasi; David A. Padua

2001-01-01T23:59:59.000Z

215

MA 125-4 CR PH 105-4 CR  

E-Print Network (OSTI)

490-3 CR Mechanical Engineering Design I I Proj Lab Proj Lab MA 125-4 CR Calculus I or Equivalent M MEMA 125-4 CR Calculus I or Equivalent PH 105-4 CR Gen Physics with Calculus MA 126-4 CR Calculus I I or Equivalent M Required Course Elective Course Prerequisite NS M W LAB Proj Lab Natural Science Mathematics

Carver, Jeffrey C.

216

A new 40 MA ranchero explosive pulsed power system  

SciTech Connect

We are developing a new high explosive pulsed power (HEPP) system based on the 1.4 m long Ranchero generator which was developed in 1999 for driving solid density z-pinch loads. The new application requires approximately 40 MA to implode similar liners, but the liners cannot tolerate the 65 {micro}s, 3 MA current pulse associated with delivering the initial magnetic flux to the 200 nH generator. To circumvent this problem, we have designed a system with an internal start switch and four explosively formed fuse (EFF) opening switches. The integral start switch is installed between the output glide plane and the armature. It functions in the same manner as a standard input crowbar switch when armature motion begins, but initially isolates the load. The circuit is completed during the flux loading phase using post hole convolutes. Each convolute attaches the inner (coaxial) output transmission line to the outside of the outer coax through a penetration of the outer coaxial line. The attachment is made with the conductor of an EFF at each location. The EFFs conduct 0.75 MA each, and are actuated just after the internal start switch connects to the load. EFFs operating at these parameters have been tested in the past. The post hole convolutes must withstand as much as 80 kV at peak dl/dt during the Ranchero load current pulse. We describe the design of this new HEPP system in detail, and give the experimental results available at conference time. In addition, we discuss the work we are doing to test the upper current limits of a single standard size Ranchero module. Calculations have suggested that the generator could function at up to {approx}120 MA, the rule of thumb we follow (1 MA/cm) suggests 90 MA, and simple flux compression calculations, along with the {approx}4 MA seed current available from our capacitor bank, suggests 118 MA is the currently available upper limit.

Goforth, James [Los Alamos National Laboratory; Herrera, Dennis [Los Alamos National Laboratory; Oona, Hank [Los Alamos National Laboratory; Torres, David [Los Alamos National Laboratory; Atchison, W L [Los Alamos National Laboratory; Colgate, S A [Los Alamos National Laboratory; Griego, J R [Los Alamos National Laboratory; Guzik, J [Los Alamos National Laboratory; Holtkamp, D B [Los Alamos National Laboratory; Idzorek, G [Los Alamos National Laboratory; Kaul, A [Los Alamos National Laboratory; Kirkpatrick, R C [Los Alamos National Laboratory; Menikoff, R [Los Alamos National Laboratory; Reardon, P T [Los Alamos National Laboratory; Reinovsky, R E [Los Alamos National Laboratory; Rousculp, C L [Los Alamos National Laboratory; Sgro, A G [Los Alamos National Laboratory; Tabaka, L J [Los Alamos National Laboratory; Tierney, T E [Los Alamos National Laboratory; Watt, R G [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

217

A Cascade Multilevel Inverter Using a Single DC Source  

E-Print Network (OSTI)

A Cascade Multilevel Inverter Using a Single DC Source Zhong Du1, Leon M. Tolbert2 3, John N inverter can be implemented using only a single DC power source and capacitors. A standard cascade multilevel inverter requires DC sources for 2 + 1 levels. Without requiring transformers, the scheme proposed

Tolbert, Leon M.

218

MaRIE theory, modeling and computation roadmap executive summary  

SciTech Connect

The confluence of MaRIE (Matter-Radiation Interactions in Extreme) and extreme (exascale) computing timelines offers a unique opportunity in co-designing the elements of materials discovery, with theory and high performance computing, itself co-designed by constrained optimization of hardware and software, and experiments. MaRIE's theory, modeling, and computation (TMC) roadmap efforts have paralleled 'MaRIE First Experiments' science activities in the areas of materials dynamics, irradiated materials and complex functional materials in extreme conditions. The documents that follow this executive summary describe in detail for each of these areas the current state of the art, the gaps that exist and the road map to MaRIE and beyond. Here we integrate the various elements to articulate an overarching theme related to the role and consequences of heterogeneities which manifest as competing states in a complex energy landscape. MaRIE experiments will locate, measure and follow the dynamical evolution of these heterogeneities. Our TMC vision spans the various pillar science and highlights the key theoretical and experimental challenges. We also present a theory, modeling and computation roadmap of the path to and beyond MaRIE in each of the science areas.

Lookman, Turab [Los Alamos National Laboratory

2010-01-01T23:59:59.000Z

219

Notices 888 First Street, NE., Washington, DC  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

11 Federal Register 11 Federal Register / Vol. 76, No. 122 / Friday, June 24, 2011 / Notices 888 First Street, NE., Washington, DC 20426. The filings in the above-referenced proceeding are accessible in the Commission's eLibrary system by clicking on the appropriate link in the above list. They are also available for review in the Commission's Public Reference Room in Washington, DC. There is an eSubscription link on the Web site that enables subscribers to receive e-mail notification when a document is added to a subscribed docket(s). For assistance with any FERC Online service, please e-mail FERCOnlineSupport@ferc.gov or call (866) 208-3676 (toll free). For TTY, call (202) 502-8659. Dated: June 20, 2011. Kimberly D. Bose, Secretary. [FR Doc. 2011-15859 Filed 6-23-11; 8:45 am]

220

Notices 888 First Street NE., Washington, DC  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

53 Federal Register 53 Federal Register / Vol. 78, No. 56 / Friday, March 22, 2013 / Notices 888 First Street NE., Washington, DC 20426. This filing is accessible on-line at http://www.ferc.gov, using the ''eLibrary'' link and is available for review in the Commission's Public Reference Room in Washington, DC. There is an ''eSubscription'' link on the Web site that enables subscribers to receive email notification when a document is added to a subscribed docket(s). For assistance with any FERC Online service, please email FERCOnlineSupport@ferc.gov, or call (866) 208-3676 (toll free). For TTY, call (202) 502-8659. Comment Date: 5:00 p.m. Eastern Time on April 2, 2013. Dated: March 15, 2013. Kimberly D. Bose, Secretary. [FR Doc. 2013-06602 Filed 3-21-13; 8:45 am] BILLING CODE 6717-01-P

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

AVTA: Hasdec DC Fast Charging Testing Results  

Energy.gov (U.S. Department of Energy (DOE))

The Vehicle Technologies Office's Advanced Vehicle Testing Activity carries out testing on a wide range of advanced vehicles and technologies on dynamometers, closed test tracks, and on-the-road. These results provide benchmark data that researchers can use to develop technology models and guide future research and development. The following report describes results from testing done on the Hasdec DC fast charging system for plug-in electric vehicles. This research was conducted by Idaho National Laboratory.

222

DC side filters for multiterminal HVDC systems  

SciTech Connect

Multiterminal HVDC systems present challenges in the specification and design of suitable dc side filtering. This document examines the existing experience and addresses the particular technical problems posed by multiterminal systems. The filtering requirements of small taps are discussed, as is the potential use of active filters. Aspects of calculation and design are considered and recommendations made to guide the planners and designers of future multiterminal schemes.

Shore, N.L.; Adamson, K.; Bard, P. [and others] [and others

1996-10-01T23:59:59.000Z

223

DOE - Office of Legacy Management -- Metals and Controls Corp FSM Dept - MA  

Office of Legacy Management (LM)

and Controls Corp FSM Dept - and Controls Corp FSM Dept - MA 21 FUSRAP Considered Sites Site: METALS AND CONTROLS CORP., FSM DEPT. ( MA.21 ) Eliminated from consideration under FUSRAP Designated Name: Not Designated Alternate Name: M&C Texas Instruments MA.21-1 Location: Attleboro , Massachusetts MA.21-1 Evaluation Year: Circa 1987 MA.21-4 Site Operations: Nuclear fuel fabrication during the 1950s and 1960s. MA.21-2 Site Disposition: Eliminated - NRC licensed MA.21-2 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Uranium MA.21-3 Radiological Survey(s): Yes MA.21-3 Site Status: Eliminated from consideration under FUSRAP MA.21-2 Also see Documents Related to METALS AND CONTROLS CORP., FSM DEPT. MA.21-1 - Texas Instruments Letter; Veale to Duffy; Subject: Further

224

Energy Incentive Programs, Washington DC | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Washington DC Washington DC Energy Incentive Programs, Washington DC October 29, 2013 - 11:29am Addthis Updated August 2013 What public-purpose-funded energy efficiency programs are available in the District of Columbia? In 2008, the Council of the District of Columbia passed the Clean and Affordable Energy Act (CAEA), establishing the DC Sustainable Energy Utility (DC SEU), whose mission is to provide energy assistance to low-income residents and support energy efficiency and renewable energy programs. The DC SEU, funded by the Sustainable Energy Trust Fund (also created by the CAEA) and under contract to the District Department of the Environment (DDOE), helps District residents, businesses, and institutions save energy and money. The DC SEU provides comprehensive energy services to targeted, prioritized

225

New leading/trailing edge modulation strategies for two-stage AC/DC PFC adapters to reduce DC-link capacitor ripple current  

E-Print Network (OSTI)

AC/DC adapters mostly employ two-stage topology: Power Factor Correction (PFC) pre-regulation stage followed by an isolated DC/DC converter stage. Low power AC/DC adapters require a small size to be competitive. Among their components, the bulk DC...

Sun, Jing

2007-09-17T23:59:59.000Z

226

Simulations for preliminary design of a multi-cathode DC electron gun for eRHIC  

SciTech Connect

The proposed electron ion collider, eRHIC, requires a large average polarized electron current of 50 mA, which is more than 20 times higher than the present experimental output of a single, highly polarized electron source, based on cesiated super-lattice GaAs. To meet eRHIC's requirement for current, we designed a multicathode DC electron gun for injection. The twenty-four GaAs cathodes emit electrons in sequence, then are combined on axis by a rotating field (or 'funnelled'). In addition to its ultra-high vacuum requirements, the multicathode DC electron gun will place high demand on the electric field symmetry, the magnetic field shielding, and on preventing arcing. In this paper, we discuss our results from a 3D simulation of the latest model for this gun. The findings will guide the actual design in future. Their preliminary design of a multi-cathode electron source for eRHIC demonstrated tolerable fields and reasonable results in both field and particle simulations.

Wu, Q.; Ben-Zvi, I.; Chang, X.; Skaritka, J.

2010-05-23T23:59:59.000Z

227

SE-MA-NO Electric Coop | Open Energy Information  

Open Energy Info (EERE)

MA-NO Electric Coop MA-NO Electric Coop Jump to: navigation, search Name SE-MA-NO Electric Coop Place Missouri Utility Id 16851 Utility Location Yes Ownership C NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Municipal HPS 100 W Lighting Municipal HPS 250 W Lighting Residential Residential Residential/Commercial HPS 100 W Lighting Residential/Commercial HPS 250 W Lighting Average Rates Residential: $0.0804/kWh Commercial: $0.0763/kWh Industrial: $0.0649/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

228

PIA - Management and Administration (MA) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

PIA - Management and Administration (MA) PIA - Management and Administration (MA) PIA - Management and Administration (MA) The E-Government Act of 2002 requires Federal agencies to perform Privacy Impact Assessments (PIAs), an analysis of how information is handled, in order: (i) to ensure handling conforms to applicable legal, regulatory, and policy requirements regarding privacy, (ii) to determine the risks and effects of collecting, maintaining and disseminating information in identifiable form in an electronic information system, and (iii) to examine and evaluate protections and alternative processes for handling information to mitigate potential privacy risks. The DOE PIA process helps to ensure privacy protections are considered and implemented throughout the system life cycle. Following are all PIAs that have been done for Management and

229

FURTHER PARTICULARS The University of Cambridge is one of the world's leading Universities, with an outstanding  

E-Print Network (OSTI)

the supervision of the Departmental Secretary. Location Centre for Mathematical Sciences, Wilberforce Road. The Department of Applied Mathematics and Theoretical Physics has approximately 150 staff, 18 secretaries, is one of the most dynamic science departments of the University of Cambridge, and over twice the size

Cambridge, University of

230

Ian Hacking. An Introduction to Probability and Inductive Logic. Cambridge University Press 2000, xvii + 302 pp.  

E-Print Network (OSTI)

Ian Hacking. An Introduction to Probability and Inductive Logic. Cambridge University Press 2000, and as an introduction to statistical inference and decision theory, it is even better. Hacking writes very clearly and engagingly throughout. A good supply of well-chosen exercises appear at the end of each chapter, and Hacking

Fitelson, Branden

231

to appear: Math. Proc. Cambridge Phil. Soc. MEASURE AND DIMENSION FUNCTIONS  

E-Print Network (OSTI)

to appear: Math. Proc. Cambridge Phil. Soc. MEASURE AND DIMENSION FUNCTIONS: MEASURABILITY several years, a new type of geometric measure and dimension have been introduced, the packing measure aspects of dy- namics and measure theory. Packing measure is a sort of dual of Hausdor measure

Mauldin, R. Daniel

232

BOOK REVIEW V.A.Rakov and M.A.Uman, Lightning: Physics and Effects, Cambridge  

E-Print Network (OSTI)

'', lightning flash counters, lightning location sys- tems (including satellite-based systems), longBOOK REVIEW V.A.Rakov and M.A.Uman, Lightning: Physics and Effects, Cambridge University Press, incredibly useful ­ schol- arly compendium of all that is known about lightning, its causes, and the many

Florida, University of

233

Fun D.C. Jobs for Physicists  

SciTech Connect

Physicists make valuable contributions in a wide variety of careers, including those in Washington. Many national challenges, including energy, innovation, and security, create a demand for technically-competent individuals across government. Clark will discuss some of the many programs in D.C. designed to attract the best and brightest minds, from grad-students to professors, from short-term assignments to whole new careers. These are great opportunities to use your expertise and enrich your knowledge of the broader scientific enterprise, all while serving society.

Clark Cully

2009-09-30T23:59:59.000Z

234

A miniature transformer/dc?dc converter for implantable medical devices  

Science Journals Connector (OSTI)

This paper presents a new technique for the design of a miniature dc?dc converter used in energy producing implantable devices such as defibrillators and advanced pacemakers. This converter is inserted in such a device and is used to boost the voltage from a low voltage implanted battery to high voltage energy storage capacitors in a short period of time. The stored energy is then delivered when needed through an energy delivery circuit in order to stimulate or defibrillate the heart. The converter takes the form of a flyback topology which includes a miniature transformer and a specialized control circuit. The transformer was designed using a new numerical synthesis method which utilizes finite elements and dynamic programming for predicting the geometries of the transformers magnetic circuit. The final transformer design satisfied the performance criteria and provided means for selecting the converter components. The obtained performance results for the transformer and the dc?dc converter were in excellent agreement with laboratory performance tests.

Osama A. Mohammed; W. Kinzy Jones

1988-01-01T23:59:59.000Z

235

Wide input range DC-DC converter with digital control scheme  

E-Print Network (OSTI)

boost converter a battery or ultracapacitor energy storage is connected to take care of the fuel cell slow transient response (200 watts/min). The robust features of the proposed control system ensure a constant output DC voltage for a variety of load...

Harfman Todorovic, Maja

2006-04-12T23:59:59.000Z

236

Washington DC's First Electric Vehicle Charging Station | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Washington DC's First Electric Vehicle Charging Station Washington DC's First Electric Vehicle Charging Station Washington DC's First Electric Vehicle Charging Station November 17, 2010 - 11:28am Addthis Street signage for Washington, DC's first electric vehicle charging station located on the northwest corner of the intersection of U and 14th streets. | Department of Energy Photo | Street signage for Washington, DC's first electric vehicle charging station located on the northwest corner of the intersection of U and 14th streets. | Department of Energy Photo | Shannon Brescher Shea Communications Manager, Clean Cities Program It's always exciting to attend a grand opening, especially when it represents a "first" for an entire region. Yesterday, the U.S. Department of Energy and the city of Washington, DC joined together to

237

Microsoft Word - MA HCM Workforce Plan.doc  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

HUMAN CAPITAL HUMAN CAPITAL MANAGEMENT WORKFORCE PLAN September 2006 This page left blank intentionally. MA Workforce Plan - September 2006 TABLE OF CONTENTS Table of Contents ........................................................................................................................... i Executive Summary ...................................................................................................................... 1 1.0 Introduction.......................................................................................................................... 3 1.1 Mission and Business Vision .........................................................................................3 1.2 Human Capital Management Strategy ...........................................................................4

238

Engineering Ethics Richard A. Burgess, M.A.  

E-Print Network (OSTI)

Engineering Ethics Richard A. Burgess, M.A. Texas Tech T-STEM Center and Deputy Director, National Institute for Engineering Ethics Summer 2012 #12;STEM includes Engineering · No single profession impacts the Rubble: An Introduction to Post-Disaster Engineering and Ethics by Sara Pfatteicher #12;Constraint

Gelfond, Michael

239

MA 387 ' SOIU' Lm Exam 2 April 16, 1982  

E-Print Network (OSTI)

MA 387 ' SOIU' Lm Exam 2 April 16, 1982. Name. (10) l _ 'Calculate each of the following; a) ?{(a,b)la < 0 and b 1 2} t: Cola) b) u{(a,b)l[a,b] 5 (1,2)}. : .Cl, 9.).

240

Ma, Bonzongo, Gao, Dong and Gress QUARTERLY PROGRESS REPORT  

E-Print Network (OSTI)

Characterization and Leachability of Coal Combustion Residues in Florida Principal investigator: Lena Q. Ma of coal combustion residues (CCR) and assess their metal leachability. The specific objectives are: 1- Environmental soil chemistry (Professor) Affiliation: Soil and Water Science Department, UF, Gainesville, FL

Ma, Lena

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Index of /~jbeckley/WD/MA 373/F14  

E-Print Network (OSTI)

... 14-Jan-2015 15:16, 418K. [ ], MA373 F14 Test 4-1.pdf, 14-Jan-2015 15:27, 330K. Apache/2.2.3 (Red Hat) Server at www.math.purdue.edu Port 80.

242

Will This #Hashtag Be Popular Tomorrow? Zongyang Ma  

E-Print Network (OSTI)

Will This #Hashtag Be Popular Tomorrow? Zongyang Ma zma4@e.ntu.edu.sg Aixin Sun axsun@ntu.edu.sg Gao Cong gaocong@ntu.edu.sg School of Computer Engineering Nanyang Technological University, Singapore this prediction problem as a classification problem and evaluate the effectiveness of the extracted features

Aixin, Sun

243

ON SOLAR NEUTRINO PROBLEM TIAN MA AND SHOUHONG WANG  

E-Print Network (OSTI)

ON SOLAR NEUTRINO PROBLEM TIAN MA AND SHOUHONG WANG Abstract. The current neutrino oscillation an alternative resolution to the solar neutrino loss problem. Contents 1. Introduction 1 2. Discrepancy of Solar, there are three flavors of neutrinos: the electron neutrino e, the tau neutrino and the mu neutrino µ. The solar

244

Glass, Brian 1 BRIAN DANIEL GLASS, M.A.  

E-Print Network (OSTI)

Glass, Brian 1 BRIAN DANIEL GLASS, M.A. University Department of Psychology, A8000 The University of Categorization and Decision Making, The University of Texas at Austin #12;Glass, Brian 2 Duties include: Programming, constructing, and running experiments, statistical analysis. JOURNAL PUBLICATIONS Glass, B. D

Maddox, W. Todd

245

Glass, Brian 1 BRIAN DANIEL GLASS, M.A.  

E-Print Network (OSTI)

Glass, Brian 1 BRIAN DANIEL GLASS, M.A. University Department of Psychology, A8000 The University Making, The University of Texas at Austin #12;Glass, Brian 2 Duties include: Designing and constructing, constructing, and running experiments, statistical analysis. JOURNAL PUBLICATIONS Glass, B. D., Chotibut, T

Maddox, W. Todd

246

Glass, Brian 1 BRIAN DANIEL GLASS, M.A.  

E-Print Network (OSTI)

Glass, Brian 1 BRIAN DANIEL GLASS, M.A. University Department of Psychology, A8000 The University of Texas at Austin Austin, TX 78712 (512) 232-2883 e-mail: glass@mail.utexas.edu EDUCATION 2006 ­ Cognitive include: Designing and constructing experiments, statistical #12;Glass, Brian 2 analysis, manuscript

Maddox, W. Todd

247

DC Bus Capacitor Manufacturing Facility for Electric Drive Vehicles  

Energy.gov (U.S. Department of Energy (DOE))

2010 DOE Vehicle Technologies and Hydrogen Programs Annual Merit Review and Peer Evaluation Meeting, June 7-11, 2010 -- Washington D.C.

248

DC Resistivity Survey (Wenner Array) At Mt Princeton Hot Springs...  

Open Energy Info (EERE)

Determination of groundwater flux patterns Notes Researchers measured DC resistivity and produced 12 resistivity profiles, each approximately 1.3 km in length. Equilibrium...

249

Low Cost, High Temperature, High Ripple Current DC Bus Capacitors  

Energy.gov (U.S. Department of Energy (DOE))

2010 DOE Vehicle Technologies and Hydrogen Programs Annual Merit Review and Peer Evaluation Meeting, June 7-11, 2010 -- Washington D.C.

250

Exploring the Raft River geothermal area, Idaho, with the dc...  

Open Energy Info (EERE)

geothermal area, Idaho, with the dc resistivity method (Abstract) Abstract GEOTHERMAL ENERGY; GEOTHERMAL FIELDS; ELECTRICAL SURVEYS; IDAHO; GEOTHERMAL EXPLORATION; RAFT RIVER...

251

MA in Modern Languages The School of Languages and Literatures invites applications for its taught MA in Modern  

E-Print Network (OSTI)

MA in Modern Languages. With dedicated academic staff in its subject areas of French, German, Italian courses on cultural and literary theory, choosing their remaining four from a broad range of options Theory Introduction to Literary Theory Minor Thesis (30 credits) Optional Modules (Four of:) French

252

DOE - Office of Legacy Management -- Tufts College - MA 0-05  

Office of Legacy Management (LM)

Tufts College - MA 0-05 Tufts College - MA 0-05 FUSRAP Considered Sites Site: TUFTS COLLEGE ( MA.0-05 ) Eliminated from further consideration under FUSRAP Designated Name: Not Designated Alternate Name: None Location: Medford , Massachusetts MA.0-05-1 Evaluation Year: 1987 MA.0-05-1 Site Operations: Research and development using only small quantities of radioactive material. MA.0-05-1 Site Disposition: Eliminated - Potential for contamination considered remote based on limited quantities of material handled MA.0-05-1 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Uranium MA.0-05-1 Radiological Survey(s): None Indicated Site Status: Eliminated from further consideration under FUSRAP Also see Documents Related to TUFTS COLLEGE MA.0-05-1 - Aerospace Letter; Young to Wallo; Subject: Elimination

253

Department.,of Energy Washington; DC'  

Office of Legacy Management (LM)

,of Energy ,of Energy Washington; DC' 20585 JAN 1 1 1995 / .,, .- L ., The Honorable Thomas Menino ', 1 City Hall Square Boston, Massachusetts 02201 ,'. " p' ifi.. ' . .' b I,' \ Dear.Mayor.Me$ino: DOE's Formerly Util,ized for identification of sites.used by*DOEfs predecessor' agencies, determining, their current radiological condition and, where it has authority, performing remedial action to cleanup sites to meet current radiologicalprotection requirements.~ A conservative set of.technical evaluation guidelines4s used in these investigat~ions' toTassure protection of public health, safety and the .environment. Where DOE does not have authority.for proceeding, the available site information is forwarded to the appropriate Federal or State Agency,. DOE studied the historical records of the former ,Tracerlab, Inc. sitei'and it

254

National Press Club Washington, D.C.  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Is the Energy Race our new Is the Energy Race our new "Sputnik" Moment? National Press Club Washington, D.C. 29 November, 2010 1 October 4, 1957, the Soviet Union placed a 184 pound satellite into orbit. "The Soviet Union now has - in the combined category of scientists and engineers - a greater number than the United States. And it is producing graduates in these fields at a much faster rate ... This trend is disturbing. Indeed, according to my scientific advisers, this is for the American people the most critical problem of all. My scientific advisers place this problem above all other immediate tasks of producing missiles, of developing new techniques in the Armed Services. We need scientists in the ten years ahead..." On November 13, 1957, President Eisenhower

255

Dissipative Cryogenic Filters with Zero DC Resistance  

SciTech Connect

The authors designed, implemented and tested cryogenic RF filters with zero DC resistance, based on wires with a superconducting core inside a resistive sheath. The superconducting core allows low frequency currents to pass with negligible dissipation. Signals above the cutoff frequency are dissipated in the resistive part due to their small skin depth. The filters consist of twisted wire pairs shielded with copper tape. Above approximately 1 GHz, the attenuation is exponential in {radical}{omega}, as typical for skin depth based RF filters. By using additional capacitors of 10 nF per line, an attenuation of at least 45 dB above 10 MHz can be obtained. Thus, one single filter stage kept at mixing chamber temperature in a dilution refrigerator is sufficient to attenuate room temperature black body radiation to levels corresponding to 10 mK above about 10 MHz.

Bluhm, Hendrik; Moler, Kathryn A.; /Stanford U., Appl. Phys. Dept

2008-04-22T23:59:59.000Z

256

D.C. Water Resources Research Center Annual Technical Report  

E-Print Network (OSTI)

years. We are in negotiation with BenTen Inc., a Japanese water purification system manufacturerD.C. Water Resources Research Center Annual Technical Report FY 2007 D.C. Water Resources Research of the District of Columbia (DC) Water Resources Research Institute (the Institute) for the period of March 1

257

Stabilization of unstable periodic orbits in dc drives  

E-Print Network (OSTI)

Electric drive using dc shunt motor or permanent magnet dc (PMDC) motor as prime mover exhibits bifurcation and chaos. The characteristics of dc shunt and PMDC motors are linear in nature. These motors are controlled by pulse width modulation (PWM) technique with the help of semiconductor switches. These switches are nonlinear element that introduces nonlinear characteristics in the drive. Any nonlinear system can exhibit bifurcation and chaos. dc shunt or PMDC drives show normal behavior with certain range of parameter values. It is also observed that these drive show chaos for significantly large ranges of parameter values. In this paper we present a method for controlling chaos applicable to dc shunt and PMDC drives. The results of numerical investigation are presented.

Krishnendu Chakrabarty; Urmila Kar

2014-02-22T23:59:59.000Z

258

Definition: DC Resistivity Survey (Dipole-Dipole Array) | Open Energy  

Open Energy Info (EERE)

DC Resistivity Survey (Dipole-Dipole Array) DC Resistivity Survey (Dipole-Dipole Array) Jump to: navigation, search Dictionary.png DC Resistivity Survey (Dipole-Dipole Array) The Dipole-Dipole array is a type of electrode configuration for a Direct-Current Resistivity Survey and is defined by its electrode array geometry.[1] View on Wikipedia Wikipedia Definition References ↑ http://appliedgeophysics.berkeley.edu/dc/EM46.pdf Ret LikeLike UnlikeLike You like this.Sign Up to see what your friends like. rieved from "http://en.openei.org/w/index.php?title=Definition:DC_Resistivity_Survey_(Dipole-Dipole_Array)&oldid=596974" Category: Definitions What links here Related changes Special pages Printable version Permanent link Browse properties 429 Throttled (bot load) Error 429 Throttled (bot load) Throttled (bot load)

259

Town of Danvers, MA Smart Grid Project | Open Energy Information  

Open Energy Info (EERE)

Smart Grid Project Smart Grid Project Jump to: navigation, search Project Lead Town of Danvers, MA Country United States Headquarters Location Danvers, Massachusetts Recovery Act Funding $8,476,800.00 Total Project Value $16,953,600.00 Coverage Area Coverage Map: Town of Danvers, MA Smart Grid Project Coordinates 42.5750946°, -70.9300507° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[]}

260

EDeMa (Smart Grid Project) | Open Energy Information  

Open Energy Info (EERE)

EDeMa EDeMa Country Germany Headquarters Location Mülheim, Germany Coordinates 51.427074°, 6.886492° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":51.427074,"lon":6.886492,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Book Review: Aristotle's Ethics as First Philosophy Claudia Baracchi Cambridge University Press, 2008 ISBN 9780521866583  

E-Print Network (OSTI)

Book Reviews Aristotle's Ethics as First Philosophy Claudia Baracchi Cambridge University Press, 2008 ISBN 9780521866583 Review by Douglas K. Fishel, University of Kansas Writing a book on Aristotle from a continental perspective with scant.... The basis of much of Baracchi's consideration in the commen tary on Books 1-7 concerns the two-fold meaning of ethos, as it con cerns both "demeanor revealing character" and "psychological con formation wherein an individual as well as a community find...

Fischel, Douglas R.

262

DOE - Office of Legacy Management -- E B Badger - MA 0-01  

Office of Legacy Management (LM)

E B Badger - MA 0-01 E B Badger - MA 0-01 FUSRAP Considered Sites Site: E.B. Badger (MA.0-01 ) Eliminated from further consideration under FUSRAP Designated Name: Not Designated Alternate Name: None Location: 75 Pitts Street , Boston , Massachusetts MA.0-01-1 Evaluation Year: 1987 MA.0-01-2 Site Operations: Construction contractor during the mid-1940s; constructed facility to refine pitchblende ore and produce feed materials at another location. MA.0-01-2 Site Disposition: Eliminated - No indication of radioactive materials handled at this site MA.0-01-2 Radioactive Materials Handled: No Primary Radioactive Materials Handled: None MA.0-01-2 Radiological Survey(s): No Site Status: Eliminated from further consideration under FUSRAP Also see Documents Related to E.B. Badger

263

E-Print Network 3.0 - ages 600-570 ma Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

The former age signature is more... , zircons have 2850 Ma cores and 2730 Ma rims. Titanite ages are similar to those from zircon rims... and zircon using LA-ICP-MS. The oldest...

264

CSC 1051 M.A. Papalaskari, Villanova University CSC 1051 Data Structures and Algorithms I  

E-Print Network (OSTI)

CSC 1051 M.A. Papalaskari, Villanova University Repetition CSC 1051 ­ Data Structures.6 Interactive Programs · 5.1 Boolean Expressions · 5.2 The if Statement · 5.4 The while Statement CSC 1051 M.A CSC 1051 M.A. Papalaskari, Villanova University #12;Flow of Control The order of statement execution

Papalaskari, Mary-Angela

265

CSC 1051 M.A. Papalaskari, Villanova University Data Representation and  

E-Print Network (OSTI)

CSC 1051 M.A. Papalaskari, Villanova University Data Representation and Applets CSC 1051 ­ Data conversions · Image representation · Java Applets CSC 1051 M.A. Papalaskari, Villanova University #12;Reverse CSC 1051 M.A. Papalaskari, Villanova University Review #12;Memory devices store data of all kinds 9278

Papalaskari, Mary-Angela

266

CSC 1051 M.A. Papalaskari, Villanova University CSC 1051 Data Structures and Algorithms I  

E-Print Network (OSTI)

CSC 1051 M.A. Papalaskari, Villanova University Repetition CSC 1051 ­ Data Structures 1051 M.A. Papalaskari, Villanova University statement 1 statement 2 statement 3 statement 4 boolean 1 statements: enable us to alter control flow CSC 1051 M.A. Papalaskari, Villanova University statement 1

Papalaskari, Mary-Angela

267

CSC 1051 M.A. Papalaskari, Villanova University CSC 1051 Data Structures and Algorithms I  

E-Print Network (OSTI)

CSC 1051 M.A. Papalaskari, Villanova University Repetition CSC 1051 ­ Data Structures 1051 M.A. Papalaskari, Villanova University statement 1 statement 2 statement 3 statement 4 boolean 1 does it take for the account balance to be double the original? CSC 1051 M.A. Papalaskari, Villanova

Papalaskari, Mary-Angela

268

MA47, a Fortran code for direct solution of indefinite sparse symmetric linear systems  

E-Print Network (OSTI)

-first search of the assembly tree ........................ 23 3.8 MA47M: calculate storage and operation countsRAL-95-001 MA47, a Fortran code for direct solution of indefinite sparse symmetric linear systems indefinite symmetric linear systems of equations. It is intended to complement the Harwell code MA27

Mihajlovic, Milan D.

269

Counterrotating brushless dc permanent magnet motor  

SciTech Connect

An brushless DC permanent magnet motor is provided for driving an autonomous underwater vehicle. In one embodiment, the motor comprises four substantially flat stators disposed in stacked relationship, with pairs of the stators being axially spaced and each of the stators comprising a tape-wound stator coil; and a first and second substantially flat rotors disposed between the spaced pairs of stators. Each of the rotors includes an annular array of permanent magnets embedded therein. A first shaft is connected to the first rotor and a second, concentric shaft is connected to the second rotor, and drive unit causes rotation of the two shafts in opposite directions. The second shaft comprises a hollow tube having a central bore therein in which the first shaft is disposed. Two different sets of bearings support the first and second shAfts. In another embodiment, the motor comprises two ironless stators and pairs and rotors mounted no opposite sides of the stators and driven by counterrotating shafts.

Hawsey, R.A.; Bailey, J.M.

1990-12-31T23:59:59.000Z

270

Counterrotating brushless dc permanent magnet motor  

SciTech Connect

An brushless DC permanent magnet motor is provided for driving an autonomous underwater vehicle. In one embodiment, the motor comprises four substantially flat stators disposed in stacked relationship, with pairs of the stators being axially spaced and each of the stators comprising a tape-wound stator coil; and a first and second substantially flat rotors disposed between the spaced pairs of stators. Each of the rotors includes an annular array of permanent magnets embedded therein. A first shaft is connected to the first rotor and a second, concentric shaft is connected to the second rotor, and drive unit causes rotation of the two shafts in opposite directions. The second shaft comprises a hollow tube having a central bore therein in which the first shaft is disposed. Two different sets of bearings support the first and second shAfts. In another embodiment, the motor comprises two ironless stators and pairs and rotors mounted no opposite sides of the stators and driven by counterrotating shafts.

Hawsey, R.A.; Bailey, J.M.

1990-01-01T23:59:59.000Z

271

We Have a Winner - DC High School Regional Science Bowl Competition...  

Office of Environmental Management (EM)

We Have a Winner - DC High School Regional Science Bowl Competition Held Last Saturday We Have a Winner - DC High School Regional Science Bowl Competition Held Last Saturday...

272

The prospects for coal-to-liquid conversion: A general equilibrium analysis Y.-H. Henry Chen a,n  

E-Print Network (OSTI)

, USA a r t i c l e i n f o Article history: Received 11 February 2011 Accepted 26 June 2011 Available prices of 2008 and continuing concern about energy security has renewed interest in more expensive energy, Washington, DC 20433, USA b MIT Joint Program on the Science and Policy of Global Change, Cambridge, MA 02139

273

DC Resistivity Survey (Dipole-Dipole Array) | Open Energy Information  

Open Energy Info (EERE)

DC Resistivity Survey (Dipole-Dipole Array) DC Resistivity Survey (Dipole-Dipole Array) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: DC Resistivity Survey (Dipole-Dipole Array) Details Activities (1) Areas (1) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Geophysical Techniques Exploration Sub Group: Electrical Techniques Parent Exploration Technique: Electrical Profiling Configurations Information Provided by Technique Lithology: Rock composition, mineral and clay content Stratigraphic/Structural: Detection of permeable pathways, fracture zones, faults Hydrological: Resistivity influenced by porosity, grain size distribution, permeability, fluid saturation, fluid type and phase state of the pore water Thermal: Resistivity influenced by temperature

274

DC Hazardous Waste Management (District of Columbia) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DC Hazardous Waste Management (District of Columbia) DC Hazardous Waste Management (District of Columbia) DC Hazardous Waste Management (District of Columbia) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State District of Columbia Program Type Environmental Regulations Provider District Department of the Environment This regulation regulates the generation, storage, transportation, treatment, and disposal of hazardous waste, and wherever feasible, reduces

275

Implementing the DC Mode in Cosmological Simulations with Supercomoving Variables  

As emphasized by previous studies, proper treatment of the density fluctuation on the fundamental scale of a cosmological simulation volume - the 'DC mode' - is critical for accurate modeling of spatial correlations on scales ~> 10% of simulation box size. We provide further illustration of the effects of the DC mode on the abundance of halos in small boxes and show that it is straightforward to incorporate this mode in cosmological codes that use the 'supercomoving' variables. The equations governing evolution of dark matter and baryons recast with these variables are particularly simple and include the expansion factor, and hence the effect of the DC mode, explicitly only in the Poisson equation.

Gnedin, Nickolay Y.; Kravtsov, Andrey V.; Rudd, Douglas H.

2011-06-02T23:59:59.000Z

276

nature biotechnology volume 29 number 2 FebruArY 2011 149 1Society of Fellows, Harvard University, Cambridge, Massachusetts, USA. 2Department of Genetics, Harvard Medical School, Boston, Massachusetts, USA. 3Wyss  

E-Print Network (OSTI)

, Cambridge, Massachusetts, USA. 2Department of Genetics, Harvard Medical School, Boston, Massachusetts, USA, USA. 4Program in Biological and Biomedical Sciences, Harvard Medical School, Boston, Massachusetts, USA. 5Department of Stem Cell and Regenerative Biology, Harvard University, Cambridge, Massachusetts

Church, George M.

277

DOE - Office of Legacy Management -- National Bureau of Standards - DC 01  

Office of Legacy Management (LM)

Bureau of Standards - DC Bureau of Standards - DC 01 FUSRAP Considered Sites Site: NATIONAL BUREAU OF STANDARDS (DC.01) Eliminated from consideration under FUSRAP Designated Name: Not Designated Alternate Name: None Location: Van Ness Street , Washington , D.C. DC.01-1 Evaluation Year: 1987 DC.01-2 DC.01-3 Site Operations: Performed quality analysis lab work for the MED during the 1940s; decontamination efforts were completed in 1952 and the building was demolished in 1976 DC.01-3 Site Disposition: Eliminated - Radiation levels Below criteria DC.01-1 Radioactive Materials Handled: Yes Primary Radioactive Materials Handled: Radium DC.01-4 Radiological Survey(s): Yes DC.01-1 Site Status: Eliminated from consideration under FUSRAP Also see Documents Related to NATIONAL BUREAU OF STANDARDS

278

Washington DC Reliability Requirements and the Need to Operate Mirant's  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Washington DC Reliability Requirements and the Need to Operate Washington DC Reliability Requirements and the Need to Operate Mirant's Potomac River Generation Station to Support Local Area Reliability (Oak Ridge National Laboratory 2005) Washington DC Reliability Requirements and the Need to Operate Mirant's Potomac River Generation Station to Support Local Area Reliability (Oak Ridge National Laboratory 2005) Pursuant to Docket No. EO-05-01: Oak Ridge National Laboratory provided an analysis of the Mirant Potomac River Generation Station in 2005 and discussed the reliability requirements of the local area and the potential impacts on reliability of changing operation of the Potomac River Generating Station in this paper. Washington DC Reliability Requirements and the Need to Operate Mirant's Potomac River Generation Station to Support Local Area Reliability.pdf

279

Categorical Exclusion Determinations: Washington, D.C. | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Washington, D.C. Washington, D.C. Categorical Exclusion Determinations: Washington, D.C. Location Categorical Exclusion Determinations issued for actions in Washington, D.C. DOCUMENTS AVAILABLE FOR DOWNLOAD June 11, 2013 CX-010460: Categorical Exclusion Determination Novel Low Cost Environmentally Friendly Synthetic Approaches toward Core-Shell Structured Micro CX(s) Applied: B3.6 Date: 06/11/2013 Location(s): District of Columbia Offices(s): National Energy Technology Laboratory March 28, 2013 CX-010567: Categorical Exclusion Determination Lawrence Berkeley National Laboratory - Rapid Automated Modeling and Simulation of Existing Buildings for Energy Efficiency CX(s) Applied: B3.6 Date: 02/28/2013 Location(s): California, District of Columbia Offices(s): Advanced Research Projects Agency-Energy

280

Electric Compressor With High-Speed Brushless DC Motor  

Science Journals Connector (OSTI)

Moving Magnet Technologies (MMT) from Besanon in France has developed a highly efficient brushless DC motor that is especially suitable for use in ... The following report presents technical details of the electric

Dr.-Ing. Stephan Biwersi; Dipl.-Ing. Stephan Tavernier; M.Sc. Samuel Equoy

2012-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

A Multilevel Voltage-Source Inverter with Separate DC Sources  

Office of Scientific and Technical Information (OSTI)

directly to a 13 kV power line. The corresponding parameters have been mentioned in Section IILC. The capacitances for the ten FBI units' dc capacitors are C,, C2, -,...

282

DC Resistivity Survey (Schlumberger Array) At Coso Geothermal Area (1977) |  

Open Energy Info (EERE)

DC Resistivity Survey (Schlumberger Array) At Coso DC Resistivity Survey (Schlumberger Array) At Coso Geothermal Area (1977) Exploration Activity Details Location Coso Geothermal Area Exploration Technique DC Resistivity Survey (Schlumberger Array) Activity Date 1977 Usefulness not indicated DOE-funding Unknown Exploration Basis To investigate electrical properties of rocks associated with thermal phenomena of the Devil's Kitchen-Coso Hot Springs area Notes 18 USGS Schlumberger soundings and 6 Schlumberger soundings by Furgerson (1973) were plotted and automatically processed and interpreted References Jackson, D.B. ODonnell, J.E.; Gregory, D. I. (1 January 1977) Schlumberger soundings, audio-magnetotelluric soundings and telluric mapping in and around the Coso Range, California Retrieved from "http://en.openei.org/w/index.php?title=DC_Resistivity_Survey_(Schlumberger_Array)_At_Coso_Geothermal_Area_(1977)&oldid=591389

283

Analysis of a transformer-less, multi-level DC-DC converter for HVDC operation  

SciTech Connect

HVDC systems require DC step up and DC step down units. The traditional approach is the application of twelve-pulse thyristor bridges with transformers. The developments of fast switching IGBT devices permit the development of transformer-less, multi-level converters. A multi-level circuit was suggested by Limpaecher. This paper presents a detailed simulation of the proposed circuit together with the analysis of its performance. The converter consists of a set of capacitors, air core inductors and solid state switches arranged in a ladder network. In the step-up mode, the closing of solid state switches resonantly charges the capacitors in parallel through an air-cored inductor. Then solid state switches resonantly charges the capacitors in parallel through an air-cored inductor. Then solid state switches connect the capacitors in series and discharge them through an air-core inductor to the load. In the step-down mode the capacitors are charged in series and discharged in parallel. The circuit has three modes of operation in each cycle: charge, inversion, and discharge. The circuit operation is analyzed in each mode using SPICE simulations. The selection of the components is discussed and output voltage regulation is analyzed. The results show that the proposed circuit promises significant reduction of losses, because of the zero current switching. The investment cost is reduced because of the elimination of transformers.

Karady, G.G.; Devarajan, S. [Arizona State Univ., Tempe, AZ (United States)

1998-12-31T23:59:59.000Z

284

In W. Sinnott-Armstrong (ed), Moral Psychology volume 3: The Neuroscience of Morality, Cambridge, Mass.: MIT Press, 273-280, 2007.  

E-Print Network (OSTI)

In W. Sinnott-Armstrong (ed), Moral Psychology volume 3: The Neuroscience of Morality, Cambridge-280" #12;In W. Sinnott-Armstrong (ed), Moral Psychology volume 3: The Neuroscience of Morality, Cambridge_00352445,version1-13Jan2009 #12;In W. Sinnott-Armstrong (ed), Moral Psychology volume 3: The Neuroscience

Paris-Sud XI, Université de

285

ACCEPTED FOR PUBLICATION IN ROBOTICA PUBLISHED BY CAMBRIDGE UNIVERSITY PRESS 1 Tracking of a Joint Path for the Walking of an  

E-Print Network (OSTI)

ACCEPTED FOR PUBLICATION IN ROBOTICA PUBLISHED BY CAMBRIDGE UNIVERSITY PRESS 1 Tracking of a Joint,version1-26Feb2013 Author manuscript, published in "Robotica 22 (2004) 15-28" #12;ACCEPTED FOR PUBLICATION IN ROBOTICA PUBLISHED BY CAMBRIDGE UNIVERSITY PRESS 2 parameter: the arc length ?. A time scaling control

Paris-Sud XI, Université de

286

Modeling and Simulation of Series DC Motors in Electric Car  

Science Journals Connector (OSTI)

Abstract The objective of this paper is assessing use of series DC motor in electric car with its rotation speed controller, and evaluating its performances when different running cases of electric car with different loads. The mathematical equations model of series DC motor and electronic inverter in dynamic state with reference frame d q were considered. Computer model of these equations was implemented using MATLAB/SIMPOWER facilities obtaining a complete model for motor and controller. Series DC motor is considered and its parameters were used for simulation. The electronic controller operates based on PWM control technique. Simulation of series DC motor performances was conducted within presumptions of changing car load and different resistant torques. Changing loads was realised changing number of passengers when electric car is running on normal streets, when running on streets with slope, when car is accelerate to reach a stead speed and when car is changing speed rigidly and suddenly running on country road having some holes and small slopes. Some conclusions and remarks about performances and behaviour of series DC motor were concluded. The simulated series DC motor was tested and mounted experimentally in a small truck car in Faculty of Mechanical & Electrical Engineering at Damascus University.

Zeina Bitar; Samih Al Jabi; Imad Khamis

2014-01-01T23:59:59.000Z

287

Fusion materials irradiations at MaRIE's fission fusion facility  

SciTech Connect

Los Alamos National Laboratory's proposed signature facility, MaRIE, will provide scientists and engineers with new capabilities for modeling, synthesizing, examining, and testing materials of the future that will enhance the USA's energy security and national security. In the area of fusion power, the development of new structural alloys with better tolerance to the harsh radiation environments expected in fusion reactors will lead to improved safety and lower operating costs. The Fission and Fusion Materials Facility (F{sup 3}), one of three pillars of the proposed MaRIE facility, will offer researchers unprecedented access to a neutron radiation environment so that the effects of radiation damage on materials can be measured in-situ, during irradiation. The calculated radiation damage conditions within the F{sup 3} match, in many respects, that of a fusion reactor first wall, making it well suited for testing fusion materials. Here we report in particular on two important characteristics of the radiation environment with relevancy to radiation damage: the primary knock-on atom spectrum and the impact of the pulse structure of the proton beam on temporal characteristics of the atomic displacement rate. With respect to both of these, analyses show the F{sup 3} has conditions that are consistent with those of a steady-state fusion reactor first wall.

Pitcher, Eric J [Los Alamos National Laboratory

2010-10-06T23:59:59.000Z

288

Data:Eec988f9-dc0d-45ef-9789-a7781dc1934b | Open Energy Information  

Open Energy Info (EERE)

f9-dc0d-45ef-9789-a7781dc1934b f9-dc0d-45ef-9789-a7781dc1934b No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: El Paso Electric Co (New Mexico) Effective date: 2010/01/01 End date if known: Rate name: LGS (Large General Service Secondary) Sector: Commercial Description: This rate is available to all Customers for lighting,power, and heating service. All service will be taken at one point of delivery designated by the Company and at one of the Company's standard types of service. Service under this rate shall be limited to Customers whose expected monthly demand will exceed 800 kilowatts (kW).

289

A Low-Cost Soft-Switched DC/DC Converter for Solid-Oxide Fuel Cells  

SciTech Connect

A highly efficient DC to DC converter has been developed for low-voltage high-current solid oxide fuel cells. The newly developed 'V6' converter resembles what has been done in internal combustion engine that split into multiple cylinders to increase the output capacity without having to increase individual cell size and to smooth out the torque with interleaving operation. The development was started with topology overview to ensure that all the DC to DC converter circuits were included in the study. Efficiency models for different circuit topologies were established, and computer simulations were performed to determine the best candidate converter circuit. Through design optimization including topology selection, device selection, magnetic component design, thermal design, and digital controller design, a bench prototype rated 5-kW, with 20 to 50V input and 200/400V output was fabricated and tested. Efficiency goal of 97% was proven achievable through hardware experiment. This DC to DC converter was then modified in the later stage to converter 35 to 63 V input and 13.8 V output for automotive charging applications. The complete prototype was tested at Delphi with their solid oxide fuel cell test stand to verify the performance of the modified DC to DC converter. The output was tested up to 3-kW level, and the efficiency exceeded 97.5%. Multiple-phase interleaving operation design was proved to be reliable and ripple free at the output, which is desirable for the battery charging. Overall this is a very successful collaboration project between the SECA Core Technology Team and Industrial Team.

Jason Lai

2009-03-03T23:59:59.000Z

290

CamGrid: Experiences in constructing a university-wide, Condor-based grid at the University of Cambridge  

E-Print Network (OSTI)

and R. Tyer, A Grid approach to Environmental Molecular Simulations: Deployment and Use of Condor pools within the eMinerals Mini Grid, Proceedings of GGF 10 (2004) [3] S. Son and M. Livny: Recovering Internet Symmetry in Distributed... CamGrid: Experiences in constructing a university-wide, Condor-based grid at the University of Cambridge M Calleja1, B Beckles4, M Keegan3, M A Hayes2, A Parker2 and M T Dove1, 3 1. Department of Earth Sciences, University of Cambridge, Downing...

Calleja, Mark; Beckles, B; Keegan, M; Hayes, Mark; Parker, A; Dove, Martin T

2008-06-26T23:59:59.000Z

291

Transportation and the Environment: Essays on Technology, Infrastructure, and Policy  

E-Print Network (OSTI)

and Health. 2003, Health Effects Institute. Boston, MA. May.Special Report, Health Effects Institute, Cambridge, MA,

Sangkapichai, Mana

2009-01-01T23:59:59.000Z

292

Factors affecting the indoor concentrations of carbonaceous aerosols of outdoor origin  

E-Print Network (OSTI)

Cambridge, MA: Health Effects Institute, Research Report No.Special Report, Health Effects Institute, Boston, MA, pp.

Lunden, Melissa M.

2009-01-01T23:59:59.000Z

293

Q&A: Kristen Psaki of WeatherizeDC | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Q&A: Kristen Psaki of WeatherizeDC Q&A: Kristen Psaki of WeatherizeDC Q&A: Kristen Psaki of WeatherizeDC April 15, 2010 - 3:45pm Addthis Roughly 20 percent of carbon emissions come from inefficient homes. The DC Project says it has found a way to mitigate emissions and create jobs, a winning combination. WeatherizeDC is the non-profit's effort to use a community engagement model to help DC residents find green jobs and live a more energy efficient lifestyle. Energy Empowers recently spoke with DC Project co-founder and creative director Kristen Psaki about WeatherizeDC's approach to climate change. WeatherizeDC is a nonprofit community engagement program. What's the background of it, the story of how and why it was founded? The DC Project was founded over a year ago in January 2009.

294

Q&A: Kristen Psaki of WeatherizeDC | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Q&A: Kristen Psaki of WeatherizeDC Q&A: Kristen Psaki of WeatherizeDC Q&A: Kristen Psaki of WeatherizeDC April 15, 2010 - 3:45pm Addthis Roughly 20 percent of carbon emissions come from inefficient homes. The DC Project says it has found a way to mitigate emissions and create jobs, a winning combination. WeatherizeDC is the non-profit's effort to use a community engagement model to help DC residents find green jobs and live a more energy efficient lifestyle. Energy Empowers recently spoke with DC Project co-founder and creative director Kristen Psaki about WeatherizeDC's approach to climate change. WeatherizeDC is a nonprofit community engagement program. What's the background of it, the story of how and why it was founded? The DC Project was founded over a year ago in January 2009.

295

A frequency domain model for 3 kV dc traction dc-side resonance identification  

SciTech Connect

Frequency-dependent effects in railway traction power systems arise from the impedance of substation and locomotive line filters and the traction line. Harmonic noise from traction drives and substations can excite resonances and produce overcurrent or overvoltage conditions at critical points in the network. In this paper, the harmonic feeding impedances of a 3 kV DC traction system seen from the rectifier substation, locomotive drive converter and pantograph terminals are presented. Several substation and locomotive filters are considered with a frequency-dependent traction line. Resonances attributed to the substation filter, locomotive filter and traction line are separate and distinct, the line introducing poles and zeros in the audio frequency (AF) range which vary in frequency and magnitude with locomotive position.

Hill, R.J. [Univ. of Bath (United Kingdom). School of Electronic and Electrical Engineering] [Univ. of Bath (United Kingdom). School of Electronic and Electrical Engineering; Fracchia, M.; Pozzobon, P.; Sciutto, G. [Univ. degli Studi di Genova (Italy). Dipt. di Ingegneria Elettrica] [Univ. degli Studi di Genova (Italy). Dipt. di Ingegneria Elettrica

1995-08-01T23:59:59.000Z

296

RECIPIENT:Hull Municipal Light Plant STATE: MA PROJECT TITLE:  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

: : Page 1 01 :L RECIPIENT:Hull Municipal Light Plant STATE: MA PROJECT TITLE: Hull Offshore Wind Research and Development Funding Opportunity Announcement Number Procurement Instrument Number NEPA Control Number CID Number 09EE0000326 DE-EE0000326 GFO-OO00326-001 0 Based on my review of the information concerning the proposed action, as NEPA Compliance Officer (authorized under DOE Order 451.1A), I have made the foUowing determination: CX, EA, EIS APPENDIX AND NUMBER: Description: A9 Information gathering (including, but not limited to, literature surveys, inventories, audits), data analysis (including computer modeling), document preparation (such as conceptual design or feasibility studies, analytical energy supply and demand studies), and dissemination (including, but not limited to, document mailings, publication, and distribution; and

297

Building America Case Study: Boiler Control Replacement for Hydronically Heated Multifamily Buildings, Cambridge, Massachusetts (Fact Sheet)  

SciTech Connect

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

Not Available

2014-11-01T23:59:59.000Z

298

Association of asthma symptoms with peak particulate air pollution and effect modification by anti-inflammatory medication use.  

E-Print Network (OSTI)

respirable aerosol. Health Effects Institute Research Report38. Cambridge, MA:Health Effects Institute, 1990. Spektor

Delfino, Ralph J; Zeiger, Robert S; Seltzer, James M; Street, Donald H; McLaren, Christine E

2002-01-01T23:59:59.000Z

299

A mathematical model for adaptive prediction of environmental changes by microorganisms  

E-Print Network (OSTI)

, Cambridge, MA, and approved March 17, 2011 (received for review January 3, 2011) Survival in natural

Pilpel, Yitzhak

300

Index of /academic/files/courses/past/2003fall/ma265/MatLab  

E-Print Network (OSTI)

Index of /academic/files/courses/past/2003fall/ma265/MatLab. [ICO], Name Last modified Size Description. [DIR], Parent Directory, -. [TXT], dotprod.

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

2.8-Ma Ash-Flow Caldera At Chegem River In The Northern Caucasus...  

Open Energy Info (EERE)

Ma Ash-Flow Caldera At Chegem River In The Northern Caucasus Mountains (Russia), Contemporaneous Granites, And Associated Ore Deposits Jump to: navigation, search OpenEI Reference...

302

E-Print Network 3.0 - alcon laboratories ma60 Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

Sample search results for: alcon laboratories ma60 Page: << < 1 2 3 4 5 > >> 1 Chemical Engineering Research Support 2007 Abitibi-Consolidated Inc. Summary: Agriculture &...

303

Model for Analysis of Energy Demand (MAED-2) | Open Energy Information  

Open Energy Info (EERE)

Analysis of Energy Demand (MAED-2) AgencyCompany Organization: International Atomic Energy Agency Sector: Energy Focus Area: Renewable Energy, Energy Efficiency Topics: Pathways...

304

MA511: PRACTICE TEST 2 Answer all questions. No calculators or ...  

E-Print Network (OSTI)

MA511: PRACTICE TEST 2. Answer all questions. No calculators or other electronic devices are allowed. For questions 1 to 3, you may write down the answers...

2014-11-02T23:59:59.000Z

305

Energy Department Completes Cool Roof Installation on DC Headquarters  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Completes Cool Roof Installation on DC Completes Cool Roof Installation on DC Headquarters Building to Save Money by Saving Energy Energy Department Completes Cool Roof Installation on DC Headquarters Building to Save Money by Saving Energy December 14, 2010 - 12:00am Addthis Washington - Secretary Steven Chu today announced the completion of a new cool roof installation on the Department of Energy's Headquarters West Building. There was no incremental cost to adding the cool roof as part of the roof replacement project and it will save taxpayers $2,000 every year in building energy costs. Cool roofs use lighter-colored roofing surfaces or special coatings to reflect more of the sun's heat, helping improve building efficiency, reduce cooling costs and offset carbon emissions. The cool roof and increased insulation at the facility were

306

News From the D.C. Office: Efficient Office Equipment  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Aerial view of Washington D.C. 3 Aerial view of Washington D.C. News From the D.C. Office Efficient Office Equipment: Update and a Look Ahead An extended version of this article is available here. We are now well aware of the large amount of energy consumed by "plug-in loads" such as personal computers (PCs) and other office electronics. Office equipment is often cited as the fastest-growing end-use of electricity in the fastest-growing sector of demand (commercial buildings). According to Dataquest figures, world growth of PCs will average 14 to 15 percent per year through 1999. Only ten years ago, office equipment was not even part of the "map" of non-residential energy end-uses. There were virtually no data on office equipment energy use, nor an awareness of the

307

Argonne TTRDC - TTR Goes to D.C.  

NLE Websites -- All DOE Office Websites (Extended Search)

Argonne's Through-the-Road Hybrid goes to Washington, D.C., Auto Show Argonne's Through-the-Road Hybrid goes to Washington, D.C., Auto Show Argonne's Through the Road Vehicle Argonne's Through-the-Road Hybrid Vehicle Argonne's Through-the-Road hybrid vehicle (TTR) will be on display at the Washington Auto Show at Walter E. Washington Convention Center, February 4-8, 2009, in Washington, D.C. The TTR will be in the combined U.S. Department of Energy, Environmental Protection Agency, and Department of Transportation exhibit booth that features advanced vehicle technologies that are safe, clean, and efficient. Due to power-split limitations, no plug-in hybrid electric vehicle (PHEV) exists that can complete an Urban Dynamometer Driving Schedule (UDDS) cycle without starting the engine. Argonne created the TTR, an in-house PHEV development platform with an open

308

DOE Solar Decathlon: News Blog » Team Capitol DC  

NLE Websites -- All DOE Office Websites (Extended Search)

Capitol DC Capitol DC Below you will find Solar Decathlon news from the Team Capitol DC archive, sorted by date. Hangout With Solar Decathlon 2013 Teams on Sept. 18! Wednesday, September 11, 2013 By Rebecca Matulka Editor's Note: This entry has been cross-posted from DOE's Energy Blog. Photo of a Solar Decathlon house at night. Superimposed is the following text: "Solar Decathlon 2013: The Path to a Brighter Future. Energy.gov/live. Wednesday, Sept. 18, at p.m. ET. #askSD." Mark your calendars for a Google+ Hangout on Solar Decathlon 2013: The Path to a Brighter Future on Wednesday, Sept. 18, at 2 p.m. ET. For more than 10 years, the U.S. Department of Energy Solar Decathlon has been preparing the next wave of energy leaders-providing hands-on experience in designing and building energy-efficient, solar-powered

309

2012 Race to DC | ENERGY STAR Buildings & Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

12 Race to DC 12 Race to DC Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In this section Why you should design to earn the ENERGY STAR Follow EPA's step-by-step process ENERGY STAR Challenge for Architects 2013 Race to Denver 2012 Race to DC 2011 Race to New Orleans 2010 Race to Miami 2009 Race to San Francisco 2008 Race to Boston 2007 Race to San Antonio

310

SAIL Venture Partners (Washington DC) | Open Energy Information  

Open Energy Info (EERE)

DC) DC) Name SAIL Venture Partners (Washington DC) Address 2900 S. Quincy St, Suite 375 Place Arlington, Virginia Zip 22206 Product Venture capital fund focusing on clean energy Year founded 2002 Phone number (703) 379-2713 Website http://www.sailvc.com/ Coordinates 38.839975°, -77.087781° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":38.839975,"lon":-77.087781,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

311

NREL: Energy Analysis - Washington D.C. Office Staff  

NLE Websites -- All DOE Office Websites (Extended Search)

Washington D.C. Office Washington D.C. Office The following SEAC staff are based in our Washington D.C. Office. They support a variety of programs and activities, and often are the liaison between the U.S. Department of Energy and staff based in Golden, Colorado. Team Lead: Margaret Mann (Golden) Administrative Support: JoAnn Weaver (Golden) Thomas Jenkin Austin Brown David J. Feldman Tom Schneider Robert Margolis Kathleen Nawaz Monisha Shah Photo of Austin Brown. Austin Brown Senior Analyst (Strategic Planning) Areas of expertise Crosscutting low-carbon strategies Clean transportation technologies and policies Primary research interests Clean energy research portfolio planning Energy and society Sustainable transportation systems More information on Austin Brown Photo of David J. Feldman

312

J. Plasma Physics (2009), vol. 75, part 5, pp. 709711. c 2009 Cambridge University Press Printed in the United Kingdom  

E-Print Network (OSTI)

J. Plasma Physics (2009), vol. 75, part 5, pp. 709­711. c 2009 Cambridge University Press Printed in the United Kingdom 709 B O O K R E V I E W Elementary Physics of Complex Plasmas, Lecture Notes on Physics0022377809990225 The treatise Elementary Physics of Complex Plasmas was written primarily for researchers

Merlino, Robert L.

313

J. Plasma Physics: page 1 of 6. c Cambridge University Press 2014 doi:10.1017/S0022377814000270  

E-Print Network (OSTI)

J. Plasma Physics: page 1 of 6. c Cambridge University Press 2014 doi:10.1017/S0022377814000270 1 Preliminary characteristics of magnetic field and plasma performance in the Magnetized Dusty Plasma Experiment 2014) The Magnetized Dusty Plasma Experiment (MDPX) device is a newly constructed research instrument

Merlino, Robert L.

314

A review of "Miltons Cambridge Latin: Performing in the Genres 1625-1632." by John K. Hale  

E-Print Network (OSTI)

he writes of it splendidly, with sure confi- dence and affection. John K. Hale. Milton?s Cambridge Latin: Performing in the Genres 1625-1632. Tempe: Arizona Center for Medieval and Renaissance Studies, 2005. xii + 305 pp. $32.00. Review by EUGENE...

Hill, Eugene D.

2007-01-01T23:59:59.000Z

315

J. Plasma Physics (1999), vol. 62, part 2, pp. 179193. Printed in the United Kingdom " 1999 Cambridge University Press  

E-Print Network (OSTI)

Cambridge University Press 179 Ion acceleration in short-pulse laser­target interactions A. A. ANDR E E V1, Skt. Petersburg, Russia 2 Faculty of Nuclear Sciences and Physical Engineering, Czech Technical produced when a powerful laser pulse is focused onto a target surface in vacuum can provide an intense

Limpouch, Jiri

316

Nuclear magnetic resonance experiments with dc SQUID amplifiers  

SciTech Connect

The development and fabrication of dc SQUIDs (Superconducting QUantum Interference Devices) with Nb/Al{sub 2}O{sub 3}/Nb Josephson junctions is described. A theory of the dc SQUID as a radio-frequency amplifier is presented, with an optimization strategy that accounts for the loading and noise contributions of the postamplifier and maximizes the signal-to-noise ratio of the total system. The high sensitivity of the dc SQUID is extended to high field NMR. A dc SQUID is used as a tuned radio-frequency amplifier to detect pulsed nuclear magnetic resonance at 32 MHz from a metal film in a 3.5 Tesla static field. A total system noise temperature of 11 K has been achieved, at a bath temperature of 4.2 K. The minimum number of nuclear Bohr magnetons observable from a free precession signal after a single pulse is about 2 {times} 10{sup 17} in a bandwidth of 25 kHz. In a separate experiment, a dc SQUID is used as a rf amplifier in a NQR experiment to observe a new resonance response mechanism. The net electric polarization of a NaClO{sub 3} crystal due to the precessing electric quadrupole moments of the Cl nuclei is detected at 30 MHz. The sensitivity of NMR and NQR spectrometers using dc SQUID amplifiers is compared to the sensitivity of spectrometers using conventional rf amplifiers. A SQUID-based spectrometer has a voltage sensitivity which is comparable to the best achieved by a FET-based spectrometer, at these temperatures and operating frequencies.

Heaney, M.B. (California Univ., Berkeley, CA (USA). Dept. of Physics Lawrence Berkeley Lab., CA (USA))

1990-11-01T23:59:59.000Z

317

Graphite electrode DC arc furnace. Innovative technology summary report  

SciTech Connect

The Graphite Electrode DC Arc Furnace (DC Arc) is a high-temperature thermal process, which has been adapted from a commercial technology, for the treatment of mixed waste. A DC Arc Furnace heats waste to a temperature such that the waste is converted into a molten form that cools into a stable glassy and/or crystalline waste form. Hazardous organics are destroyed through combustion or pyrolysis during the process and the majority of the hazardous metals and radioactive components are incorporated in the molten phase. The DC Arc Furnace chamber temperature is approximately 593--704 C and melt temperatures are as high as 1,500 C. The DC Arc system has an air pollution control system (APCS) to remove particulate and volatiles from the offgas. The advantage of the DC Arc is that it is a single, high-temperature thermal process that minimizes the need for multiple treatment systems and for extensive sorting/segregating of large volumes of waste. The DC Arc has the potential to treat a wide range of wastes, minimize the need for sorting, reduce the final waste volumes, produce a leach resistant waste form, and destroy organic contaminants. Although the DC arc plasma furnace exhibits great promise for treating the types of mixed waste that are commonly present at many DOE sites, several data and technology deficiencies were identified by the Mixed Waste Focus Area (MWFA) regarding this thermal waste processing technique. The technology deficiencies that have been addressed by the current studies include: establishing the partitioning behavior of radionuclides, surrogates, and hazardous metals among the product streams (metal, slag, and offgas) as a function of operating parameters, including melt temperature, plenum atmosphere, organic loading, chloride concentration, and particle size; demonstrating the efficacy of waste product removal systems for slag and metal phases; determining component durability through test runs of extended duration, evaluating the effect of feed composition variations on process operating conditions and slag product performance; and collecting mass balance and operating data to support equipment and instrument design.

NONE

1999-05-01T23:59:59.000Z

318

High voltage dc--dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules. 5 Figs.

Shimer, D.W.; Lange, A.C.

1995-05-23T23:59:59.000Z

319

High voltage dc-dc converter with dynamic voltage regulation and decoupling during load-generated arcs  

DOE Patents (OSTI)

A high-power power supply produces a controllable, constant high voltage output under varying and arcing loads. The power supply includes a voltage regulator, an inductor, an inverter for producing a high frequency square wave current of alternating polarity, an improved inverter voltage clamping circuit, a step up transformer, an output rectifier for producing a dc voltage at the output of each module, and a current sensor for sensing output current. The power supply also provides dynamic response to varying loads by controlling the voltage regulator duty cycle and circuitry is provided for sensing incipient arc currents at the output of the power supply to simultaneously decouple the power supply circuitry from the arcing load. The power supply includes a plurality of discrete switching type dc--dc converter modules.

Shimer, Daniel W. (Danville, CA); Lange, Arnold C. (Livermore, CA)

1995-01-01T23:59:59.000Z

320

Development of a Hydronic Rooftop Unit-HyPak-MA  

SciTech Connect

The majority of U.S. commercial floor space is cooled by rooftop HVAC units (RTUs). RTU popularity derives chiefly from their low initial cost and relative ease of service access without disturbing building occupants. Unfortunately, current RTUs are inherently inefficient due to a combination of characteristics that unnecessarily increase cooling loads and energy use. 36% percent of annual U.S. energy, and two-thirds of electricity, is consumed in and by buildings. Commercial buildings consume approximately 4.2 quads of energy each year at a cost of $230 billion per year, with HVAC equipment consuming 1.2 quads of electricity. More than half of all U.S. commercial floor space is cooled by packaged HVAC units, most of which are rooftop units (RTUs). Inefficient RTUs create an estimated 3.5% of U.S. CO{sub 2} emissions, thus contributing significantly to global warming5. Also, RTUs often fail to maintain adequate ventilation air and air filtration, reducing indoor air quality. This is the second HyPak project to be supported by DOE through NETL. The prior project, referred to as HyPak-1 in this report, had two rounds of prototype fabrication and testing as well as computer modeling and market research. The HyPak-1 prototypes demonstrated the high performance capabilities of the HyPak concept, but made it clear that further development was required to reduce heat exchanger cost and improve system reliability before HyPak commercialization can commence. The HyPak-1 prototypes were limited to about 25% ventilation air fraction, limiting performance and marketability. The current project is intended to develop a 'mixed-air' product that is capable of full 0-100% modulation in ventilation air fraction, hence it was referred to as HyPak-MA in the proposal. (For simplicity, the -MA has been dropped when referencing the current project.) The objective of the HyPak Project is to design, develop and test a hydronic RTU that provides a quantum improvement over conventional RTU performance. Our proposal targeted 60% and 50% reduction in electrical energy use by the HyPak RTU for dry and humid climates, respectively, when compared with a conventional unit, and reduction in peak energy consumption of 50% and 33% respectively. In addition to performance targets, our goal is to develop a production-ready design with durability, reliability and maintainability similar to air-cooled packaged equipment, and that can be commercialized immediately following the conclusion of this project.

Eric Lee; Mark Berman

2009-11-14T23:59:59.000Z

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Active dc filter for HVDC system--A test installation in the Konti-Skan DC link at Lindome converter station  

SciTech Connect

The purpose of introducing active dc filters is to meet the more and more stringent requirement from power utilities on limiting telephone interference caused by harmonic currents from HVdc transmission lines, without unnecessarily increasing the cost of HVdc stations. An active dc filter installed in the Konti-Skan HVdc link is described. The active dc filter is connected at the bottom of an existing passive dc filter at the Lindome station. The active dc filter includes optic harmonic current measuring unit, control system, protection and supervision system, PWM power amplifier, high-frequency transformer, surge arrester, and coupling apparatuses. The active dc filter has small physical size and occupies small ground area. The performance of the active dc filter for eliminating the disturbing harmonics is excellent. To achieve comparable results by passive filters would require something like ten times more high voltage equipment.

Zhang, Wenyan; Asplund, G. (ABB Power Systems, Ludvika (Sweden). HVDC Division); Aberg, A. (ABB Corporate Research, Lund (Sweden). Dept. of Man-Machine Communication); Jonsson, U. (Svenska Kraftnaet, Vaellingby (Sweden)); Loeoef, O. (Vattenfall AB, Trollhaettan (Sweden). Region Vaestsverige)

1993-07-01T23:59:59.000Z

322

Design and analysis of a zero-voltage switching scheme for a dc- to-dc converter  

E-Print Network (OSTI)

. Singh (Member) (Memberl E. G. guak (Member) A. 3. Pat, ton Head of Department) December 199'2 ABSTRA('T Design and Analysis of a Zero-4'oltage Switching Si. heme for a. Dc-to-Dc Converter. (December Iq'3'd) G. Arun, H. S. , College Of Engg...&rt~RV, Page 40 Voltage across inain switch in a clc cliopper clrive with zeio-voltage s w 1 't C 1 1 i l1 g , &g CHAPTER I INTRODUCTION A. Introduction In general terms, power electronics is concerned wit, h the conversion and control of electrical...

Arun, G.

2012-06-07T23:59:59.000Z

323

The pottery from a fifth century B.C. shipwreck at Ma'agan Michael, Israel  

E-Print Network (OSTI)

Between 1988 and 1990 a shipwreck tentatively dated to the 5th century B.C. was excavated off the coast of Israel at Ma'agan Michael by Dr. Elisha Linder of the Center for Maritime Studies. This study presents one category of material from the Ma...

Lyon, Jerry Dean

2012-06-07T23:59:59.000Z

324

MaJIC: a Matlab Just-In-time Compiler ? George Almasi and David A. Padua  

E-Print Network (OSTI)

MaJIC: a Matlab Just-In-time Compiler ? George Almasi and David A. Padua galmasi experience with MaJIC, a just-in- time compiler for MATLAB. In the recent past, several compiler projects claimed large performance improvements when processing MATLAB code. Most of these projects are static

Padua, David

325

M.A. in Political Science Degree Requirements Department of Political Science, Florida Atlantic University  

E-Print Network (OSTI)

M.A. in Political Science Degree Requirements Department of Political Science, Florida Atlantic University Students pursuing a Master of Arts Degree in Political Science are required to meet the following as an undergraduate. 4. Students entering the M.A. program who did not major in political science as undergraduates

Fernandez, Eduardo

326

Photo 2008 Michigan State University Board of Trustees M.A. Advertising  

E-Print Network (OSTI)

Photo © 2008 Michigan State University Board of Trustees M.A. Advertising M.A. Public Relations GRADUATE HANDBOOK Department of Advertising + Public Relations MICHIGAN STATE UNIVERSITY #12;2 Revised July 2013 Table of Contents Program overview, 3 Two degrees: Advertising or PR, 3 Program structure, 4

327

Institutions and Cross-border Mergers and Acquisitions (M&A) Value Creation  

E-Print Network (OSTI)

institutions on cross-border M&A value creation. I further examine the moderating effects of host country political institutions on the relationship between host country regulatory institutions and cross-border M&A value creation. Moreover, I investigate...

Zhu, Hong

2012-02-14T23:59:59.000Z

328

U-178: VMware vMA Library Loading Error Lets Local Users Gain...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

A vulnerability was reported in VMware vMA PLATFORM: Version(s): vMA 4.0, 4.1, 5 patch 1 (5.0.0.1) ABSTRACT: A local user can obtain elevated privileges on the target...

329

Electromagnetic Coupling in a dc Motor and Tachometer Assembly  

E-Print Network (OSTI)

-pole permanent magnet stator devices. A shaft of finite stiffness connects the tachometer and motor armatures machines. The experimental test setup consists of an integrated permanent magnet dc motor-tachometer unit-tachometer shaft or a flexible mechanical coupling, this exercise in servo-control design becomes quite challenging

Awtar, Shorya

330

Natural Gas Pipeline Leaks Across Washington, DC Robert B. Jackson,,,  

E-Print Network (OSTI)

Natural Gas Pipeline Leaks Across Washington, DC Robert B. Jackson,,, * Adrian Down, Nathan G increased in recent decades, but incidents involving natural gas pipelines still cause an average of 17 fatalities and $133 M in property damage annually. Natural gas leaks are also the largest anthropogenic

Jackson, Robert B.

331

Hybrid Multilevel Inverter with Single DC Haiwen Liu1  

E-Print Network (OSTI)

Hybrid Multilevel Inverter with Single DC Source Haiwen Liu1 , Leon M. Tolbert1, 2 , Burak Ozpineci Knoxville, TN 37932 3. Parker-Hannifin Corp. Olive Branch, MI 38654 Abstract- A hybrid multilevel inverter inverter (one leg for each phase) and H-bridge in series with each inverter leg. The inverter can be used

Tolbert, Leon M.

332

Decomposition of Naphthalene by dc Gliding Arc Gas Discharge  

Science Journals Connector (OSTI)

Decomposition of Naphthalene by dc Gliding Arc Gas Discharge ... In the air and oxygen gliding arc discharges, the naphthalene degradation is mainly governed by reactions with oxygen-derived radicals. ... Therefore, the local electric field strength is relatively low in argon gliding arc plasma. ...

Liang Yu; Xiaodong Li; Xin Tu; Yu Wang; Shengyong Lu; Jianhua Yan

2009-12-11T23:59:59.000Z

333

Fuzzy Estimation of DC Motor Winding Currents Innovatia Software  

E-Print Network (OSTI)

stator windings. an attractive alternative to current estimation using In order to implement an eFuzzy Estimation of DC Motor Winding Currents Dan Simon Innovatia Software 775 Rothrock Circle °ux is rotated in the desired direction of ofuzzy ¯ltering to motor winding current estimation

Simon, Dan

334

Electrostatic coalescence system with independent AC and DC hydrophilic electrodes  

DOE Patents (OSTI)

An improved electrostatic coalescence system is provided in which independent AC and DC hydrophilic electrodes are employed to provide more complete dehydration of an oil emulsion. The AC field is produced between an AC electrode array and the water-oil interface wherein the AC electrode array is positioned parallel to the interface which acts as a grounded electrode. The emulsion is introduced into the AC field in an evenly distributed manner at the interface. The AC field promotes drop-drop and drop-interface coalescence of the water phase in the entering emulsion. The continuous oil phase passes upward through the perforated AC electrode array and enters a strong DC field produced between closely spaced DC electrodes in which small dispersed droplets of water entrained in the continuous phase are removed primarily by collection at hydrophilic DC electrodes. Large droplets of water collected by the electrodes migrate downward through the AC electrode array to the interface. All phase separation mechanisms are utilized to accomplish more complete phase separation.

Hovarongkura, A. David (Arlington, VA); Henry, Jr., Joseph D. (Morgantown, WV)

1981-01-01T23:59:59.000Z

335

Hydrogen Storage Systems Analysis Working Group Meeting Argonne DC Offices  

E-Print Network (OSTI)

Hydrogen Storage Systems Analysis Working Group Meeting Argonne DC Offices L'Enfant Plaza and Kristin Deason Sentech, Inc. January 16, 2008 #12;SUMMARY REPORT Hydrogen Storage Systems Analysis Objectives This meeting was one of a continuing series of biannual meetings of the Hydrogen Storage Systems

336

EE443L Lab 2: Modeling a DC Motor Introduction  

E-Print Network (OSTI)

and add conversion factors. Copy the LabVIEW VI lab2.vi and its associated subVI Altera the four conversion factors. Motor voltage is measured with a voltage divider to ensure DAQ card analog: The DC motor is a common actuator in control systems that converts electrical energy into rotational

Wedeward, Kevin

337

National Energy Education Summit to Electrify D.C.  

Office of Energy Efficiency and Renewable Energy (EERE)

On January 26, energy educators from across the country will convene in Washington, D.C., to address the need for nationwide energy literacy. Join us for the National Energy Education Summit, hosted by the Council of Energy Research and Education Leaders.

338

High Voltage DC Transmission 2 1.0 Introduction  

E-Print Network (OSTI)

1 High Voltage DC Transmission 2 1.0 Introduction Interconnecting HVDC within an AC system requires on use of switching devices collectively referred to in the HVDC community as valves. Valves may be non. Fig. 1 There have been three types of devices for implementing HVDC converter circuits: mercury

McCalley, James D.

339

Market Acceptance of Advanced Automotive Technologies Model (MA3T) Consumer  

Open Energy Info (EERE)

Market Acceptance of Advanced Automotive Technologies Model (MA3T) Consumer Market Acceptance of Advanced Automotive Technologies Model (MA3T) Consumer Choice Model Jump to: navigation, search Tool Summary Name: Market Acceptance of Advanced Automotive Technologies Model (MA3T) Consumer Choice Model Agency/Company /Organization: Oak Ridge National Laboratory OpenEI Keyword(s): EERE tool, Market Acceptance of Advanced Automotive Technologies Model (MA3T) Consumer Choice Model, MA3T Project U.S. consumer demand for plug-in hybrid electric vehicles (PHEV) in competition among various light-duty vehicle technologies for hundreds of market segments based and multiple regions. For more information, contact the ORNL Energy and Transportation Science Division at http://www.ornl.gov/sci/ees/etsd/contactus.shtml References Retrieved from

340

VIDEO SEMINAR of Ma Jun's 6/17/02 presentation: China's Water Resources:  

NLE Websites -- All DOE Office Websites (Extended Search)

VIDEO SEMINAR of Ma Jun's 6/17/02 presentation: China's Water Resources: VIDEO SEMINAR of Ma Jun's 6/17/02 presentation: China's Water Resources: Crisis and Opportunity Speaker(s): Ma Jun Date: July 3, 2002 - 12:00pm Location: 90-3122 The rivers in China, and the hundreds of millions who depend on them, are in trouble. A water crisis looms large in most parts of China. In his book, China Water Crisis, Ma Jun traces 4,000 years of the history of China's watersheds, and their mis/management. Armed with scientific data and compelling stories, Ma reveals the causes and character of the looming ecological disaster. His book has been quoted in The Economist and many western media. Limited water resources pose a major threat to social and economic development in the 21st century. Three Gorges Dam and redirecting water from south to north occupy the main focus of the efforts to increase

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Biochemical characterization of derivatives of MA-T12D11, a TAFI neutralizing antibody  

E-Print Network (OSTI)

106ka(1/Ms) scFvFabMAT12D11 0 1 2 3 4 5 6 7 8 9 0 10 20 30 40 50 60 70 80 90 100 110 MA T12D11 Fab T12D11 scFvT12D11 Molar excess of MA/Fab/scFv % i n h i b i t i o n o f T A F I a a c t i v i t y Table 1: Binding parameters (ka, kd and KA) of MA...-T12D11 and its derivatives for binding to TAFI The results represent mean ? SD (n a1 3) Figure 4: % inhibition of TAFIa activity by MA/Fab/scFv TAFI was activated with T/TM in presence of MA, Fab or scFv. The results represent mean ? SD (n a2 3...

Develter, J.; Declerck, P. J.; Gils, A.

2006-10-27T23:59:59.000Z

342

Recovery Act: Integrated DC-DC Conversion for Energy-Efficient Multicore Processors  

SciTech Connect

In this project, we have developed the use of thin-film magnetic materials to improve in energy efficiency of digital computing applications by enabling integrated dc-dc power conversion and management with on-chip power inductors. Integrated voltage regulators also enables fine-grained power management, by providing dynamic scaling of the supply voltage in concert with the clock frequency of synchronous logic to throttle power consumption at periods of low computational demand. The voltage converter generates lower output voltages during periods of low computational performance requirements and higher output voltages during periods of high computational performance requirements. Implementation of integrated power conversion requires high-capacity energy storage devices, which are generally not available in traditional semiconductor processes. We achieve this with integration of thin-film magnetic materials into a conventional complementary metal-oxide-semiconductor (CMOS) process for high-quality on-chip power inductors. This project includes a body of work conducted to develop integrated switch-mode voltage regulators with thin-film magnetic power inductors. Soft-magnetic materials and inductor topologies are selected and optimized, with intent to maximize efficiency and current density of the integrated regulators. A custom integrated circuit (IC) is designed and fabricated in 45-nm CMOS silicon-on-insulator (SOI) to provide the control system and power-train necessary to drive the power inductors, in addition to providing a digital load for the converter. A silicon interposer is designed and fabricated in collaboration with IBM Research to integrate custom power inductors by chip stacking with the 45-nm CMOS integrated circuit, enabling power conversion with current density greater than 10A/mm2. The concepts and designs developed from this work enable significant improvements in performance-per-watt of future microprocessors in servers, desktops, and mobile devices. These new approaches to scaled voltage regulation for computing devices also promise significant impact on electricity consumption in the United States and abroad by improving the efficiency of all computational platforms. In 2006, servers and datacenters in the United States consumed an estimated 61 billion kWh or about 1.5% of the nation's total energy consumption. Federal Government servers and data centers alone accounted for about 10 billion kWh, for a total annual energy cost of about $450 million. Based upon market growth and efficiency trends, estimates place current server and datacenter power consumption at nearly 85 billion kWh in the US and at almost 280 billion kWh worldwide. Similar estimates place national desktop, mobile and portable computing at 80 billion kWh combined. While national electricity utilization for computation amounts to only 4% of current usage, it is growing at a rate of about 10% a year with volume servers representing one of the largest growth segments due to the increasing utilization of cloud-based services. The percentage of power that is consumed by the processor in a server varies but can be as much as 30% of the total power utilization, with an additional 50% associated with heat removal. The approaches considered here should allow energy efficiency gains as high as 30% in processors for all computing platforms, from high-end servers to smart phones, resulting in a direct annual energy savings of almost 15 billion kWh nationally, and 50 billion kWh globally. The work developed here is being commercialized by the start-up venture, Ferric Semiconductor, which has already secured two Phase I SBIR grants to bring these technologies to the marketplace.

Shepard, Kenneth L

2013-03-31T23:59:59.000Z

343

Dynamic Resistance of YBCO-Coated Conductors in Applied AC Fields with DC Transport Currents and DC Background Fields  

SciTech Connect

In order to predict heat loads in future saturable core fault-current-limiting devices due to ac fringing fields, dynamic resistance in YBCO-coated conductors was measured at 77 K in peak ac fields up to 25 mT at 60 Hz and in dc fields up to 1 T. With the sample orientation set such that the conductor face was either parallel or perpendicular to the ac and dc applied fields, the dynamic resistance was measured at different fractions of the critical current to determine the relationship between the dc transport current and the applied fields. With respect to field orientation, the dynamic resistance for ac fields that were perpendicular to the conductor face was significantly higher than when the ac fields were parallel to the conductor face. It was also observed that the dynamic resistance: (1) increased with increasing fraction of the dc transport current to the critical current, (2) was proportional to the inverse of the critical current, and (3) demonstrated a linear dependence with the applied ac field once a threshold field was exceeded. This functional behavior was consistent with a critical state model for the dynamic resistance, but discrepancies in absolute value of the dynamic resistance suggested that further theoretical development is needed.

Duckworth, Robert C [ORNL] [ORNL; Zhang, Yifei [ORNL] [ORNL; Ha, Tam T [ORNL] [ORNL; Gouge, Michael J [ORNL] [ORNL

2011-01-01T23:59:59.000Z

344

Train the Teacher - Energy Workshops for DC-area Elementary School...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Train the Teacher - Energy Workshops for DC-area Elementary School Teachers Train the Teacher - Energy Workshops for DC-area Elementary School Teachers May 2, 2014 1:00PM to 4:15PM...

345

Policy Flash 2013-76 Term Assignments of Contractors to the DC...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6 Term Assignments of Contractors to the DC Area Policy Flash 2013-76 Term Assignments of Contractors to the DC Area Questions concerning this policy flash should be directed to A...

346

A Segmented Drive System with a Small DC Bus Capacitor | Department...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

-- Washington D.C. apep08su.pdf More Documents & Publications A Segmented Drive Inverter Topology with a Small DC Bus Capacitor A Segmented Drive Inverter Topology with a...

347

D.C. Middle and High School Students Get a Chance to Experience...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

D.C. Middle and High School Students Get a Chance to Experience the Regional Science Bowl Competition Setting D.C. Middle and High School Students Get a Chance to Experience the...

348

Energy Secretary Moniz's Remarks at CSIS in Washington D.C. on...  

Office of Environmental Management (EM)

Energy Secretary Moniz's Remarks at CSIS in Washington D.C. on Energy Security 40 Years after the Embargo - As Delivered Energy Secretary Moniz's Remarks at CSIS in Washington D.C....

349

DC powerline communication system using a transmission line transformer for high degree of freedom applications  

E-Print Network (OSTI)

A new type of powerline communication is developed to reduce cable requirements for robotic, electromechanical, and vehicular systems. A DC power bus line connecting a DC power supply to motor drives and sensor units is ...

Wade, Eric R. (Eric Randolph), 1978-

2004-01-01T23:59:59.000Z

350

Hanford External Dosimetry Technical Basis Manual PNL-MA-842  

SciTech Connect

The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNLs Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNLs Electronic Records & Information Capture Architecture (ERICA) database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document.

Rathbone, Bruce A.

2009-08-28T23:59:59.000Z

351

Interviews in Washington, DC for Albert Einstein Fellowship Semi-Finalists  

Energy.gov (U.S. Department of Energy (DOE))

Selected semi-finalists in the Albert Einstein Distinguished Educator Fellowship are invited to DC for interviews.

352

Proceedings of the National Hydrogen Energy Roadmap Workshop: Washington, DC; April 2-3, 2002  

Energy.gov (U.S. Department of Energy (DOE))

Summary of the Proceedings of the National Hydrogen Energy Roadmap Workshop held April 2-3, 2002 in Washington, DC.

353

Secretary Moniz's Remarks at the Powering Africa Summit in Washington, D.C.-- As Delivered  

Energy.gov (U.S. Department of Energy (DOE))

Secretary Moniz's remarks, as delivered, at the Power Africa Summit in Washington, D.C. on January 29, 2015.

354

A Decentralized Protection Scheme for Converters Utilizing a DC-link Inductor  

E-Print Network (OSTI)

- as in HVDC transmission for example - as well as in DC-links for high-power current source inverters

Lipo, Thomas

355

Speed control of DC motor based on neural net and fuzzy logic  

Science Journals Connector (OSTI)

This paper presented the speed control of DC motor based on neural net and fuzzy logic. To bypass the difficulties caused by system constraints and modelling uncertainties of the speed control of DC motor a neural network approach for on-line speed control ... Keywords: DC motor, fuzzy logic, neural network, speed control

Zahra Moravej

2005-09-01T23:59:59.000Z

356

BEAM DYNAMICS SIMULATIONS FOR A DC GUN BASED INJECTOR F.Zhou 1,2,  

E-Print Network (OSTI)

BEAM DYNAMICS SIMULATIONS FOR A DC GUN BASED INJECTOR FOR PERL* F.Zhou 1,2, , I.Ben-Zvi2 , X for this machine are being extensively investigated at BNL. One of the possible options is photocathode DC gun. The schematic layout of a PERL DC gun based injector and its preliminary beam dynamics are presented

Brookhaven National Laboratory

357

November 2002 15th TOFE, Washington, D.C. 1 Thermal Behavior and Operating  

E-Print Network (OSTI)

November 2002 15th TOFE, Washington, D.C. 1 Thermal Behavior and Operating Requirements of IFE Washington, D.C. November 2002 #12;November 2002 15th TOFE, Washington, D.C. 2 Abstract During injection the thermal behavior of the target under such conditions and explores possible ways of extending the target

Raffray, A. René

358

Control of a Fuel-Cell Powered DC Electric Vehicle Motor  

E-Print Network (OSTI)

Control of a Fuel-Cell Powered DC Electric Vehicle Motor Federico Zenith Sigurd Skogestad of a Fuel-Cell Powered DC Electric Vehicle Motor #12;3 Currently Available Models and Control Strategies Skogestad, Control of a Fuel-Cell Powered DC Electric Vehicle Motor #12;3 Currently Available Models

Skogestad, Sigurd

359

Towards Building an Optimal Demand Response Framework for DC Distribution Networks  

E-Print Network (OSTI)

Towards Building an Optimal Demand Response Framework for DC Distribution Networks Hamed Mohsenian, an optimization-based foundation is proposed for demand response in DC distribution networks in presence to assess the performance and to gain insights into the proposed demand-response paradigm. Keywords: DC

Mohsenian-Rad, Hamed

360

DSP IMPLEMENTATION OF DC VOLTAGE REGULATION USING ADAPTIVE CONTROL FOR 200 KW 62000 RPM  

E-Print Network (OSTI)

to control the DC voltage for 200 kW induction generator rated at a speed of 62000 RPM under different load to regulate the DC voltage for high speed induction generators rated from 5 kW to 200 kW. ii #12DSP IMPLEMENTATION OF DC VOLTAGE REGULATION USING ADAPTIVE CONTROL FOR 200 KW 62000 RPM INDUCTION

Wu, Thomas

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

On the optimization of a dc arcjet diamond chemical vapor deposition reactor  

E-Print Network (OSTI)

On the optimization of a dc arcjet diamond chemical vapor deposition reactor S. W. Reevea) and W. A precursor in our dc arcjet reactor.1 Based on conclusions drawn from that work, an optimization strategy diamond film growth in a dc arcjet chemical vapor deposition reactor has been developed. Introducing

Dandy, David

362

A direct AC-to-DC converter topology with high-frequency isolation  

E-Print Network (OSTI)

-to-ac converter eliminating the acto-dc rectification stage, power factor correction boost stage, and dc-dc converter stage present in the conventional system. The output of the high-frequency isolation transformer is rectified and processed via a filtering stage...

Sulistyono, Widodo

2012-06-07T23:59:59.000Z

363

FRACTIONAL SKEW MONOID RINGS P. ARA, M.A. GONZ'ALEZ-BARROSO, K.R. GOODEARL, AND E. PARDO  

E-Print Network (OSTI)

FRACTIONAL SKEW MONOID RINGS P. ARA, M.A. GONZ'ALEZ-BARROSO #12; 2 P. ARA, M.A. GONZ'ALEZ-BARROSO, K.R. GOODEARL, AND E. PARDO In this paper

Bigelow, Stephen

364

Hanford External Dosimetry Technical Basis Manual PNL-MA-842  

SciTech Connect

The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with requirements of 10 CFR 835, the DOE Laboratory Accreditation Program, the DOE Richland Operations Office, DOE Office of River Protection, DOE Pacific Northwest Office of Science, and Hanfords DOE contractors. The dosimetry system is operated by the Pacific Northwest National Laboratory (PNNL) Hanford External Dosimetry Program which provides dosimetry services to PNNL and all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNLs Electronic Records & Information Capture Architecture database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Maintenance and distribution of controlled hard copies of the manual by PNNL was discontinued beginning with Revision 0.2.

Rathbone, Bruce A.

2011-04-04T23:59:59.000Z

365

Hanford External Dosimetry Technical Basis Manual PNL-MA-842  

SciTech Connect

The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at Hanford. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with 10 CFR 835, DOELAP, DOE-RL, ORP, PNSO, and Hanford contractor requirements. The dosimetry system is operated by PNNLs Hanford External Dosimetry Program (HEDP) which provides dosimetry services to all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee (HPDAC) which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. Rev. 0 marks the first revision to be released through PNNLs Electronic Records & Information Capture Architecture (ERICA) database. Revision numbers that are whole numbers reflect major revisions typically involving changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Revision Log: Rev. 0 (2/25/2005) Major revision and expansion. Rev. 0.1 (3/12/2007) Minor revision. Updated Chapters 5, 6 and 9 to reflect change in default ring calibration factor used in HEDP dose calculation software. Factor changed from 1.5 to 2.0 beginning January 1, 2007. Pages on which changes were made are as follows: 5.23, 5.69, 5.78, 5.80, 5.82, 6.3, 6.5, 6.29, 9.2.

Rathbone, Bruce A.

2007-03-12T23:59:59.000Z

366

Hanford External Dosimetry Technical Basis Manual PNL-MA-842  

SciTech Connect

The Hanford External Dosimetry Technical Basis Manual PNL-MA-842 documents the design and implementation of the external dosimetry system used at the U.S. Department of Energy (DOE) Hanford site. The manual describes the dosimeter design, processing protocols, dose calculation methodology, radiation fields encountered, dosimeter response characteristics, limitations of dosimeter design under field conditions, and makes recommendations for effective use of the dosimeters in the field. The manual describes the technical basis for the dosimetry system in a manner intended to help ensure defensibility of the dose of record at Hanford and to demonstrate compliance with requirements of 10 CFR 835, the DOE Laboratory Accreditation Program, the DOE Richland Operations Office, DOE Office of River Protection, DOE Pacific Northwest Office of Science, and Hanfords DOE contractors. The dosimetry system is operated by the Pacific Northwest National Laboratory (PNNL) Hanford External Dosimetry Program which provides dosimetry services to PNNL and all Hanford contractors. The primary users of this manual are DOE and DOE contractors at Hanford using the dosimetry services of PNNL. Development and maintenance of this manual is funded directly by DOE and DOE contractors. Its contents have been reviewed and approved by DOE and DOE contractors at Hanford through the Hanford Personnel Dosimetry Advisory Committee which is chartered and chaired by DOE-RL and serves as means of coordinating dosimetry practices across contractors at Hanford. This manual was established in 1996. Since its inception, it has been revised many times and maintained by PNNL as a controlled document with controlled distribution. The first revision to be released through PNNLs Electronic Records & Information Capture Architecture database was designated Revision 0. Revision numbers that are whole numbers reflect major revisions typically involving significant changes to all chapters in the document. Revision numbers that include a decimal fraction reflect minor revisions, usually restricted to selected chapters or selected pages in the document. Maintenance and distribution of controlled hard copies of the manual by PNNL was discontinued beginning with Revision 0.2.

Rathbone, Bruce A.

2010-04-01T23:59:59.000Z

367

DC Resistivity Survey (Schlumberger Array) At Raft River Geothermal Area  

Open Energy Info (EERE)

Area Area (1974-1975) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Activity: DC Resistivity Survey (Schlumberger Array) At Raft River Geothermal Area (1974-1975) Exploration Activity Details Location Raft River Geothermal Area Exploration Technique DC Resistivity Survey (Schlumberger Array) Activity Date 1974 - 1975 Usefulness not indicated DOE-funding Unknown Exploration Basis Hydrogeologic study of the area Notes In 1975, the U.S. Geological Survey made 70 Schlumberger resistivity soundings in the Upper Raft River Valley and in parts of the Raft River Valley. These soundings complement the 79 soundings made previously in the Raft River Valley and bring the total number of soundings to 149. This work was done as part of a hydrogeologic study of the area. The location,

368

Commuting and health in Cambridge: a study of a 'natural experiment' in the provision of new transport infrastructure  

E-Print Network (OSTI)

, they are approached using a combination of recruitment stands, newspaper and magazine advertise- ments, posters, fliers, and announcements distributed on the investigators behalf by employers through corporate email distribution lists, intranets and staff newsletters... two areas of Cambridge city (Barnwell and Romsey Town) with similar aggregate socioeconomic and spatial characteristics to those of the urban parts of the intervention area but with no direct access to the busway, as well as a 180 sector...

Ogilvie, David; Griffin, Simon J; Jones, Andy; Mackett, Roger; Guell, Cornelia; Panter, Jenna R; Jones, Natalia; Cohn, Simon; Yang, Lin; Chapman, Cheryl

2010-11-16T23:59:59.000Z

369

All undergraduate/Bachelor degrees BSc/BA/BEng/MEng 13,000 Childhood Studies MA 12,500  

E-Print Network (OSTI)

All undergraduate/Bachelor degrees BSc/BA/BEng/MEng £13,000 Childhood Studies MA £12,500 Developmental and Therapeutic Play MA/PGDip/PGCert £12,500 Health Care Management MSc £13,000 Public Health/BA/BEng/MEng £11,750 Ancient Egyptian Culture MA £12,500 Ancient History & Classical Culture MA £12,500 Ancient

Harman, Neal.A.

370

www.math.tu-berlin.de/mathe-ini Di, 10.4. 11:30 MA 844 Frhstck  

E-Print Network (OSTI)

www.math.tu-berlin.de/mathe-ini Di, 10.4. 11:30 MA 844 Frühstück Im Mathetreff gibt es gratis Kaffee und Brötchen für alle Erstsemester (Mathe, WiMa, TechMa). Studis, die im Café oder der Ini aktiv sind, beantworten deine Fragen. Do, 12.4. 18:00 MA 847 Erstes Iniplenum Die Ini trifft sich ungefähr

Nabben, Reinhard

371

Disc rotors with permanent magnets for brushless dc motor  

SciTech Connect

This patent describes a brushless dc permanent magnet motor for driving an autonomous underwater vehicle. It comprises first and second substantially flat, generally cylindrical stators disposed in side by side relation; a first substantially flat, generally cylindrical rotor; a first shaft connected to the first rotor and a second, concentric shaft connected to the second rotor; and means for providing rotation of the first and second shafts in opposite directions.

Hawsey, R.A.; Bailery, J.M.

1992-05-26T23:59:59.000Z

372

Synthesis of silicon nanotubes by DC arc plasma method  

SciTech Connect

Plasma synthesis is a novel technique of synthesis of nanomaterials as they provide high rate of production and promote metastable reactions. Very thin walled silicon nanotubes were synthesized in a DC direct arc thermal plasma reactor. The effect of parameters of synthesis i.e. arc current and presence of hydrogen on the morphology of Si nanoparticles is reported. Silicon nanotubes were characterized by Transmission Electron Microscopy (TEM), Local Energy Dispersive X-ray analysis (EDAX), and Scanning Tunneling Microscopy (STM).

Tank, C. M.; Bhoraskar, S. V.; Mathe, V. L. [Department of Physics, University of Pune, Pune-7, Maharashtra (India)

2012-06-05T23:59:59.000Z

373

!#"%$'&)(02130546708913@A4B0DC Scott Schaefer, Joe Warren  

E-Print Network (OSTI)

¢¡¤£¦¥¨§©©¡ !#"%$'&)(¤02130546708913£@¡A4B0DC Scott Schaefer, Joe Warren Rice UniversityE: for each edge in the grid that contains a sign change (i.e.; the vertices on its end- points these methods primal methods. i e-mail: p sschaefe,jwarrenq @rice.edu Figure 1: A sphere contoured using

Warren, Joe

374

A dc superconducting fault current limiter using die-pressed  

Science Journals Connector (OSTI)

A model of a superconducting fault current limiter on a polycrystalline high-temperature superconductor basis is checked in the dc short circuit regime. Protection of load takes place under the conditions described in this paper. The use of ceramic materials with superconducting-normal metal-superconducting Josephson junction network having an S-type current-voltage characteristic (CVC) is shown to be effective for fault current limiter devices.

A G Mamalis; M I Petrov; D A Balaev; K A; D M Gohfeld; S V Militsyn; S G; V I Kirko; I N Vottea

2001-01-01T23:59:59.000Z

375

Report on Non-Contact DC Electric Field Sensors  

SciTech Connect

This document reports on methods used to measure DC electrostatic fields in the range of 100 to 4000 V/m using a non-contact method. The project for which this report is written requires this capability. Non-contact measurements of DC fields is complicated by the effect of the accumulation of random space-charges near the sensors which interfere with the measurement of the field-of-interest and consequently, many forms of field measurements are either limited to AC measurements or use oscillating devices to create pseudo-AC fields. The intent of this document is to report on methods discussed in the literature for non-contact measurement of DC fields. Electric field meters report either the electric field expressed in volts per distance or the voltage measured with respect to a ground reference. Common commercial applications for measuring static (DC) electric fields include measurement of surface charge on materials near electronic equipment to prevent arcing which can destroy sensitive electronic components, measurement of the potential for lightning to strike buildings or other exposed assets, measurement of the electric fields under power lines to investigate potential health risks from exposure to EM fields and measurement of fields emanating from the brain for brain diagnostic purposes. Companies that make electric field sensors include Trek (Medina, NY), MKS Instruments, Boltek, Campbell Systems, Mission Instruments, Monroe Electronics, AlphaLab, Inc. and others. In addition to commercial vendors, there are research activities continuing in the MEMS and optical arenas to make compact devices using the principles applied to the larger commercial sensors.

Miles, R; Bond, T; Meyer, G

2009-06-16T23:59:59.000Z

376

Maryland DC Virginia Solar Energy Industries Association MDV SEIA | Open  

Open Energy Info (EERE)

DC Virginia Solar Energy Industries Association MDV SEIA DC Virginia Solar Energy Industries Association MDV SEIA Jump to: navigation, search Name Maryland-DC-Virginia Solar Energy Industries Association (MDV-SEIA) Place Bethesda, Maryland Zip 20814-3954 Sector Solar Product Trade associaton to promote solar equipment in the Mid-Atlantic region in US. Coordinates 40.020185°, -81.073819° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.020185,"lon":-81.073819,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

377

Multiphase soft switched DC/DC converter and active control technique for fuel cell ripple current elimination  

DOE Patents (OSTI)

DC/DC converter has a transformer having primary coils connected to an input side and secondary coils connected to an output side. Each primary coil connects a full-bridge circuit comprising two switches on two legs, the primary coil being connected between the switches on each leg, each full-bridge circuit being connected in parallel wherein each leg is disposed parallel to one another, and the secondary coils connected to a rectifying circuit. An outer loop control circuit that reduces ripple in a voltage reference has a first resistor connected in series with a second resistor connected in series with a first capacitor which are connected in parallel with a second capacitor. An inner loop control circuit that reduces ripple in a current reference has a third resistor connected in series with a fourth resistor connected in series with a third capacitor which are connected in parallel with a fourth capacitor.

Lai, Jih-Sheng (Blacksburg, VA); Liu, Changrong (Sunnyvale, CA); Ridenour, Amy (Salem, VA)

2009-04-14T23:59:59.000Z

378

2.8-Ma Ash-Flow Caldera At Chegem River In The Northern Caucasus Mountains  

Open Energy Info (EERE)

2.8-Ma Ash-Flow Caldera At Chegem River In The Northern Caucasus Mountains 2.8-Ma Ash-Flow Caldera At Chegem River In The Northern Caucasus Mountains (Russia), Contemporaneous Granites, And Associated Ore Deposits Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: 2.8-Ma Ash-Flow Caldera At Chegem River In The Northern Caucasus Mountains (Russia), Contemporaneous Granites, And Associated Ore Deposits Details Activities (0) Areas (0) Regions (0) Abstract: Diverse latest Pliocene volcanic and plutonic rocks in the north-central Caucasus Mountains of southern Russia are newly interpreted as components of a large caldera system that erupted a compositionally zoned rhyolite-dacite ash-flow sheet at 2.83 ± 0.02 Ma (sanidine and biotite 40Ar/39Ar). Despite its location within a cratonic collision zone, the Chegem system is structurally and petrologically similar to typical

379

Price of Everett, MA Natural Gas LNG Imports from Egypt (Nominal...  

Gasoline and Diesel Fuel Update (EIA)

Egypt (Nominal Dollars per Thousand Cubic Feet) Price of Everett, MA Natural Gas LNG Imports from Egypt (Nominal Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3...

380

Price of Everett, MA Natural Gas LNG Imports from Algeria (Dollars...  

Gasoline and Diesel Fuel Update (EIA)

Algeria (Dollars per Thousand Cubic Feet) Price of Everett, MA Natural Gas LNG Imports from Algeria (Dollars per Thousand Cubic Feet) Decade Year-0 Year-1 Year-2 Year-3 Year-4...

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Telecommunications Concentration: Grady College MA Non-Thesis Program Planning Form  

E-Print Network (OSTI)

Telecommunications Concentration: Grady College MA Non-Thesis Program Planning Form Student Methodology in Mass Communication 3. JRMC 8025 ( ) Mass Media Law OR JRMC 8120 ( ) Telecommunications Policy in Media Industries JRMC 8200 ( ) Media Management JRMC 8210 ( ) Telecommunications Policy JRMC 8220

Arnold, Jonathan

382

Telecommunications Concentration: Grady College MA Non-Thesis Program Planning Form  

E-Print Network (OSTI)

Telecommunications Concentration: Grady College MA Non-Thesis Program Planning Form Student JRMC 8210 ( ) Telecommunications Policy JRMC 8220 ( ) Telecommunications Programming and Criticism JRMC 8230 ( ) Emerging Telecommunications Technologies JRMC 8240 ( ) Special Topics in Telecommunications

Arnold, Jonathan

383

University Timetabling through Conceptual Jonathan Lee,1,* Shang-Pin Ma,1,  

E-Print Network (OSTI)

University Timetabling through Conceptual Modeling Jonathan Lee,1,* Shang-Pin Ma,1, Lien Fu Lai,2 system. Expertise helps in reducing the search space and in fitting the solution to the context

Lee, Jonathan

384

E-Print Network 3.0 - agente compatibilizante pe-g-ma Sample...  

NLE Websites -- All DOE Office Websites (Extended Search)

pe-g-ma Page: << < 1 2 3 4 5 > >> 1 Creep Analysis of Bamboo High-Density Polyethylene Composites: Effect of Interfacial Treatment and Fiber Summary: , the use of maleic...

385

Optimization models in finance Ma 450 Darinka Dentcheva Fall 2012 darinka.dentcheva@stevens.edu  

E-Print Network (OSTI)

Optimization models in finance Ma 450 Darinka Dentcheva Fall 2012 darinka and dynamic optimization problems occurring in finance. We shall discuss linear and non-linear optimization models of finance, dynamic (se- quential) optimization, optimization under uncertainty, mathematical

Dentcheva, Darinka

386

E-Print Network 3.0 - alloy-ma-956 Sample Search Results  

NLE Websites -- All DOE Office Websites (Extended Search)

<< < 1 2 > >> 1 UPDATE ON THE STATUS OF ODS ALLOYS FOR FOSSIL ENERGY APPLICATIONS I.G. Wright and B.A. Pint Summary: h cycles), starting at 1 to 2kh for ODS alloys MA956 and...

387

DC Regional High School Science Bowl | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

DC Regions » DC Regional High DC Regions » DC Regional High School Science Bowl National Science Bowl® (NSB) NSB Home About High School High School Students High School Coaches High School Regionals High School Rules, Forms, and Resources Middle School Attending National Event Volunteers 2013 Competition Results News Media WDTS Home Contact Information National Science Bowl® U.S. Department of Energy SC-27/ Forrestal Building 1000 Independence Ave., SW Washington, DC 20585 P: 202-586-6702 E: National.Science.Bowl@science.doe.gov Washington DC Regions DC Regional High School Science Bowl Print Text Size: A A A RSS Feeds FeedbackShare Page Regional Coordinator Information Name: Jamie T. Scipio Email: jamie.scipio@hq.doe.gov Regional Event Information Date: Saturday, February 22, 2014 Maximum Number of Teams: 12

388

News From the D.C. Office: Energy-Saving Office Equipment Part 2  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Aerial view of Washington D.C. 3 Aerial view of Washington D.C. News From the D.C. Office Energy-Saving Office Equipment Part 2: Making the "Virtual Office" Real More on the DC Office efficiency up-grade: Lighting, Office Equipment: Part 1 Regular readers of the Center for Building Science News know that energy-efficient lighting and office equipment can have significant environmental and economic benefits. Previous articles ("Monitored Savings from Energy-Efficient Lighting in D.C. Office" [Spring 1997, p. 3] and "Energy-Saving Office equipment" [Summer 1997, p. 3]) discussed these features of Berkeley Lab's Washington, D.C. office. The D.C. office also serves as a demonstration site for telecommunications technologies, which have energy and environmental benefits of their own.

389

Energy Challenge Two: The WeatherizeDC Campaign | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Energy Challenge Two: The WeatherizeDC Campaign Energy Challenge Two: The WeatherizeDC Campaign Energy Challenge Two: The WeatherizeDC Campaign June 14, 2010 - 9:15am Addthis John Lippert In my quest to learn what other local groups are doing to help the environment and hopefully avoid reinventing the wheel, I attended a meeting of the Greenbelt Climate Action Network, a local chapter of the grassroots, nonprofit organization Chesapeake Climate Action Network. There I met two WeatherizeDC field organizers who described the work they are doing. Terrance and Heather explained that WeatherizeDC is a campaign of The DC Project, a nonprofit based in Washington, D.C., founded by former leaders of the Obama for America campaign around a mission to advance economic and environmental justice by creating clean energy career opportunities for

390

DC Regional Middle School Science Bowl | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

DC Regions » DC Regional Middle DC Regions » DC Regional Middle School Science Bowl National Science Bowl® (NSB) NSB Home About High School Middle School Middle School Students Middle School Coaches Middle School Regionals Middle School Rules, Forms, and Resources Attending National Event Volunteers 2013 Competition Results News Media WDTS Home Contact Information National Science Bowl® U.S. Department of Energy SC-27/ Forrestal Building 1000 Independence Ave., SW Washington, DC 20585 P: 202-586-6702 E: National.Science.Bowl@science.doe.gov Washington DC Regions DC Regional Middle School Science Bowl Print Text Size: A A A RSS Feeds FeedbackShare Page Regional Coordinator Information Name: Chester Scott Email: chester.scott@hq.doe.gov Regional Event Information Date: Saturday, February 8, 2014 Maximum Number of Teams: 12

391

Solar Decathlon at Home in the D.C. Community | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Solar Decathlon at Home in the D.C. Community Solar Decathlon at Home in the D.C. Community Solar Decathlon at Home in the D.C. Community Addthis A New Energy-Efficient Home in the D.C. Community 1 of 27 A New Energy-Efficient Home in the D.C. Community On December 4, 2012, the Empowerhouse team, along with partners and community members, completed the installation of a permanent, two-family home in Washington, D.C. The home was originally showcased as part of the U.S Department of Energy's Solar Decathlon 2011. Image: Sarah Gerrity Date taken: 2012-12-04 12:22 2 of 27 The house is located in the D.C. neighborhood of Deanwood, which is just 10 miles from the National Mall. By installing the house nearby, the team was able to minimize shipping costs, therefore reducing the house's carbon footprint. Image: Sarah Gerrity

392

Data:D28923dc-45dc-45e5-b62b-3ca789517591 | Open Energy Information  

Open Energy Info (EERE)

923dc-45dc-45e5-b62b-3ca789517591 923dc-45dc-45e5-b62b-3ca789517591 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Northern States Power Co - Minnesota Effective date: 2012/05/01 End date if known: Rate name: SMALL GENERAL TIME OF DAY SERVICE Low Wattage (A22) Sector: Commercial Description: Customer Charge per Month (Please see page 5-24.1) Available to any non-residential customer for single or three phase electric service supplied through one meter. DETERMINATION OF CUSTOMER BILLS Customer bills shall reflect energy charges (if applicable) based on customer's kWh usage, plus a customer charge (if applicable), plus demand charges (if applicable) based on customer's kW billing demand as defined. INTERIM RATE ADJUSTMENT A 4.49% Interim Rate Surcharge will be applied to rate components specified in the "Interim Rate Surcharge Rider." In addition, customer bills under this rate are subject to the following adjustments and/or charges. FUEL CLAUSE Bills are subject to the adjustments provided for in the Fuel Clause Rider. RESOURCE ADJUSTMENT Bills are subject to the adjustments provided for in the Conservation Improvement Program Adjustment Rider, the State Energy Policy Rate Rider, the Renewable Development Fund Rider, the Transmission Cost Recovery Rider, the Renewable Energy Standard Rider and the Mercury Cost Recovery Rider. ENVIRONMENTAL IMPROVEMENT RIDER Bills are subject to the adjustments provided for in the Environmental Improvement Rider.

393

MA092 Geometria plana e analitica Comprimento da circunfer^encia -Area de superficies planas  

E-Print Network (OSTI)

MA092 ­ Geometria plana e anal´itica Comprimento da circunfer^encia - ´Area de superf´icies planas uma volta: 2R = D 61, 5 cm Dist^ancia total: 10.000.000 cm N´umero de voltas: 10.000.000/(61, 5) 51 - IMECC)MA092 ­ Geometria plana e anal´itica Agosto de 2013 5 / 22 ´Areas Ret^angulo ´Area AR = b · h

Gomes, Francisco A. M.

394

MA FAshiON bUsiNEss MA FAshiON MArKETiNg ANd cOMMUNicATiON  

E-Print Network (OSTI)

and South Korea. jhy1492@naver.com Image: Tesco, Retail Fashion Brand. By: Hyeyoun Jun #12;yU li (AMy) MA, and the influence it has on fashion brands and the future of this technology. psk_sawa@hotmail.com Image: 3-D Transform Themselves in the Thai Fashion Market, by creating their Own Brand. My project researches new

Evans, Paul

395

Communication accepte: Healthy Buildings/IAQ'97 Washington DC, septembre 1997Communication accepte: Healthy Buildings/IAQ'97 Washington DC, septembre 1997 DISCRIMINATION OF VOLATILE ORGANIC COMPOUNDS  

E-Print Network (OSTI)

Communication acceptée: Healthy Buildings/IAQ'97 Washington DC, septembre 1997Communication acceptée: Healthy Buildings/IAQ'97 Washington DC, septembre 1997 DISCRIMINATION OF VOLATILE ORGANIC manuscript, published in "4th International Conference on Healthy Buildings'97, Washington : United States

Paris-Sud XI, Université de

396

Emploi du temps Licence de Mathmatiques semestre 6 MA= parcours maths approfondies M= parcours maths MI= parcours math-info ( groupe C en LI2)  

E-Print Network (OSTI)

M= parcours maths MI= parcours math-info ( groupe C en LI2) 08h00-09h30 09h45-11h15 11h30-13h00 13h15-14h45 15h00-16h30 16h45-18h15 lundi MA MA M M MI MI mardi MA Anglais MA M TD Histoire des Maths M 3.2 M MI Anglais MI mercredi MA TD Variable Complexe M 3.2 MA M M MI MI jeudi MA MA M M MI MI

Berger, Clemens

397

Proposal of DC shield reactor type superconducting fault current limiter  

Science Journals Connector (OSTI)

Saturated DC reactor type superconducting fault current limiter (SFCL) had been proposed two years ago. It was classified to rectifier type SFCL. The changing inductance value with the operating mode has superior characteristics to reduce voltage sag during step increase of the load current. But it has the disadvantage of its weight. In this paper, rectifier type SFCL with shielded reactor has been proposed. The reactor which has superconducting ring or tube inside its winding is substituted to the DC link of the rectifier. The configuration looks like an air core transformer with secondary short winding. When the current through the bulk shield-ring reaches to a certain level, the flux penetrates to the shield body and finite impedance appears in the primary winding. In other words, when the surface flux density exceeds its critical flux density, the flux penetrates into the bulk superconductor, and increases equivalent inductance. The equivalent transient resistance of the shield was represented as a function of exponential of the time. Using this equivalent transient resistance, the transient impedance was expressed. The transient wave analysis using EMTDC (electro-magnetic transients in DC systems) has been described. Simulated waveforms are shown considering the source inductance, the leakage inductance, the coupling coefficient and the forward voltage drop of the semiconductor. And voltage sag was also investigated with 50% step load increase. Preliminary design was also performed. The coil size and number of turns are designed to obtain adequate inductance for the current limitation, and the central magnetic field of the coils are calculated. There is optimal aspect ratio to minimize the magnetic field with restriction in outer diameter of the coil.

Itsuya Muta; Tsutomu Hoshino; Khosru Mohammad Salim; Akio Kawasaki; Taketsune Nakamura; Masato Yamada

2004-01-01T23:59:59.000Z

398

DC Resistivity Survey (Wenner Array) | Open Energy Information  

Open Energy Info (EERE)

Wenner Array) Wenner Array) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: DC Resistivity Survey (Wenner Array) Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Geophysical Techniques Exploration Sub Group: Electrical Techniques Parent Exploration Technique: Vertical Electrical Sounding Configurations Information Provided by Technique Lithology: Rock composition, mineral and clay content Stratigraphic/Structural: Detection of permeable pathways, fracture zones, faults Hydrological: Resistivity influenced by porosity, grain size distribution, permeability, fluid saturation, fluid type and phase state of the pore water Thermal: Resistivity influenced by temperature Dictionary.png

399

DC Resistivity Survey (Pole-Dipole Array) | Open Energy Information  

Open Energy Info (EERE)

Pole-Dipole Array) Pole-Dipole Array) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: DC Resistivity Survey (Pole-Dipole Array) Details Activities (0) Areas (0) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Geophysical Techniques Exploration Sub Group: Electrical Techniques Parent Exploration Technique: Electrical Profiling Configurations Information Provided by Technique Lithology: Rock composition, mineral and clay content Stratigraphic/Structural: Detection of permeable pathways, fracture zones, faults Hydrological: Resistivity influenced by porosity, grain size distribution, permeability, fluid saturation, fluid type and phase state of the pore water Thermal: Resistivity influenced by temperature Dictionary.png

400

DC Resistivity Survey (Schlumberger Array) | Open Energy Information  

Open Energy Info (EERE)

Schlumberger Array) Schlumberger Array) Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Exploration Technique: DC Resistivity Survey (Schlumberger Array) Details Activities (2) Areas (2) Regions (0) NEPA(0) Exploration Technique Information Exploration Group: Geophysical Techniques Exploration Sub Group: Electrical Techniques Parent Exploration Technique: Vertical Electrical Sounding Configurations Information Provided by Technique Lithology: Rock composition, mineral and clay content Stratigraphic/Structural: Detection of permeable pathways, fracture zones, faults Hydrological: Resistivity influenced by porosity, grain size distribution, permeability, fluid saturation, fluid type and phase state of the pore water Thermal: Resistivity influenced by temperature

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Heteroepitaxial Ge-on-Si by DC magnetron sputtering  

SciTech Connect

The growth of Ge on Si(100) by DC Magnetron Sputtering at various temperatures is studied by Spectroscopic Ellipsometry and Transmission Electron Microscopy. Smooth heteroepitaxial Ge films are prepared at relatively low temperatures of 380C. Typical Stransky-Krastanov growth is observed at 410C. At lower temperatures (320C), films are essentially amorphous with isolated nanocrystallites at the Si-Ge interface. A minor oxygen contamination at the interface, developing after ex-situ oxide removal, is not seen to hinder epitaxy. Compensation of dislocation-induced acceptors in Ge by sputtering from n-doped targets is proposed.

Steglich, Martin; Schrempel, Frank; Fchsel, Kevin; Kley, Ernst-Bernhard [Institute of Applied Physics, Abbe Center of Photonics, Friedrich Schiller University, Albert-Einstein-Strae 15, 07745 Jena (Germany)] [Institute of Applied Physics, Abbe Center of Photonics, Friedrich Schiller University, Albert-Einstein-Strae 15, 07745 Jena (Germany); Patzig, Christian; Berthold, Lutz; Hche, Thomas [Fraunhofer Institute for Mechanics of Materials IWM, Walter-Hlse-Strae 1, 06120 Halle (Germany)] [Fraunhofer Institute for Mechanics of Materials IWM, Walter-Hlse-Strae 1, 06120 Halle (Germany); Tnnermann, Andreas [Institute of Applied Physics, Abbe Center of Photonics, Friedrich Schiller University, Albert-Einstein-Strae 15, 07745 Jena (Germany) [Institute of Applied Physics, Abbe Center of Photonics, Friedrich Schiller University, Albert-Einstein-Strae 15, 07745 Jena (Germany); Fraunhofer Institute for Applied Optics and Precision Engineering IOF, Albert-Einstein-Str. 7, 07745 Jena (Germany)

2013-07-15T23:59:59.000Z

402

The dc modeling program (DCMP): Version 2. 0  

SciTech Connect

In this project one of the main objectives was the refinement of tools for the study of HVDC systems. The original software was prepared in project RP1964-2 (EL-4365) as power flow and stability program models for HVDC systems. In this project new modeling capabilities were added to both the power flow and stability models. Additionally, the HVDC specific model capabilities were integrated into a new program, termed the Standalone program, for use in the development and testing of HVDC models. This manual provides technical background for programmers and those interested in understanding, augmenting or transporting the dc models.

Chapman, D.G. (Manitoba HVDC Research Centre, Winnipeg, MB (Canada))

1990-08-01T23:59:59.000Z

403

News From the D.C. Office: Monitored Savings from Energy-Efficient Lighting  

NLE Websites -- All DOE Office Websites (Extended Search)

3 Aerial view of Washington D.C. 3 Aerial view of Washington D.C. News From the D.C. Office Monitored Savings from Energy-Efficient Lighting in D.C. Office More on the DC Office efficiency up-grade: Office Equipment: Part 1, Part 2 Figure 1: Lighting energy use profile for a typical exterior office. Berkeley Lab's office in Washington, D.C. is located a few blocks from DOE headquarters, in a five-year-old office building constructed mainly for lease to Federal agencies and their contractors. Despite its recent vintage, the building's standard lighting specifications were far from today's best, cost-effective practice. In designing the build-out plans for offices and meeting rooms in our 7,500-square-foot suite, we wanted to showcase some of the energy-efficient lighting and office equipment developed for DOE's Building Technologies

404

Edison Revisited: Should we use DC Circuits for Lighting in Commercial  

NLE Websites -- All DOE Office Websites (Extended Search)

Edison Revisited: Should we use DC Circuits for Lighting in Commercial Edison Revisited: Should we use DC Circuits for Lighting in Commercial Buildings? Speaker(s): Brinda Thomas Date: March 7, 2012 - 12:30pm Location: 90-3122 Seminar Host/Point of Contact: Chris Marnay This seminar summarizes work from a forthcoming Energy Policy paper and thoughts on future work to understand the economics of DC building circuits. We examined the economic feasibility of a general application of DC building circuits to operate commercial lighting systems. We compare light-emitting diodes (LEDs) and fluorescents that are powered by either a central DC power supply or traditional AC grid electricity, with and without solar photovoltaics (PV) and battery back-up. We find that there are limited life-cycle ownership cost and capital cost benefits of DC

405

U-178: VMware vMA Library Loading Error Lets Local Users Gain Elevated  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8: VMware vMA Library Loading Error Lets Local Users Gain 8: VMware vMA Library Loading Error Lets Local Users Gain Elevated Privileges U-178: VMware vMA Library Loading Error Lets Local Users Gain Elevated Privileges May 29, 2012 - 7:00am Addthis PROBLEM: A vulnerability was reported in VMware vMA PLATFORM: Version(s): vMA 4.0, 4.1, 5 patch 1 (5.0.0.1) ABSTRACT: A local user can obtain elevated privileges on the target system. Reference Links: SecurityTracker Alert ID: 1027099 CVE-2012-2752 Vendor Advisory IMPACT ASSESSMENT: High Discussion: A local user can exploit a library loading error to cause arbitrary code to be executed on the target system with elevated privileges. Impact: Privilege escalation Solution: The vendor has issued a fix (vSphere Management Assistant 5.0 Patch 2 (5.0.0.2)). Addthis Related Articles T-591: VMware vmrun Utility Lets Local Users Gain Elevated Privileges

406

Washington, D.C. and Indiana: Allison Hybrid Technology Achieves Commercial Success  

Office of Energy Efficiency and Renewable Energy (EERE)

EERE partner, Allison Transmission, Inc., has achieved commercial success in the greater Washington, D.C. area, with 1,480 hybrid buses on the road.

407

Optimizing Energy Savings from Direct-DC in U.S. Residential Buildings  

E-Print Network (OSTI)

Appliance type Standard technology DC-internal best technology Lighting Incandescent, fluorescent, LED Incandescent Electronic Heating Heater Electric resistance Cooling Motor (& compressor,

Garbesi, Karina

2012-01-01T23:59:59.000Z

408

An Active Filter Approach to the Reduction of the DC Link Capacitor  

Energy.gov (U.S. Department of Energy (DOE))

2009 DOE Hydrogen Program and Vehicle Technologies Program Annual Merit Review and Peer Evaluation Meeting, May 18-22, 2009 -- Washington D.C.

409

Design and Modeling of Centralized Distribution Network for the DC House Project.  

E-Print Network (OSTI)

?? This thesis focuses on the design, modeling, simulation, and performance evaluation of Centralized Distribution Network for the DC House Project. Power System Computer Aided (more)

Bassi, Harpreet S.

2013-01-01T23:59:59.000Z

410

A Segmented Drive Inverter Topology with a Small DC Bus Capacitor  

Energy.gov (U.S. Department of Energy (DOE))

2010 DOE Vehicle Technologies and Hydrogen Programs Annual Merit Review and Peer Evaluation Meeting, June 7-11, 2010 -- Washington D.C.

411

Zeolitization Of Intracaldera Sediments And Rhyolitic Rocks In The 1.25 Ma  

Open Energy Info (EERE)

Zeolitization Of Intracaldera Sediments And Rhyolitic Rocks In The 1.25 Ma Zeolitization Of Intracaldera Sediments And Rhyolitic Rocks In The 1.25 Ma Lake Of Valles Caldera, New Mexico, Usa Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: Zeolitization Of Intracaldera Sediments And Rhyolitic Rocks In The 1.25 Ma Lake Of Valles Caldera, New Mexico, USA Details Activities (0) Areas (0) Regions (0) Abstract: Quantitative X-ray diffraction analysis of about 80 rhyolite and associated lacustrine rocks has characterized previously unrecognized zeolitic alteration throughout the Valles caldera resurgent dome. The alteration assemblage consists primarily of smectite-clinoptilolite-mordenite-silica, which replaces groundmass and fills voids, especially in the tuffs and lacustrine rocks. Original rock textures are routinely preserved. Mineralization typically extends to

412

U.S. DEPARTMENT OF ENERGY EERE PROJECT MA.i\IAGE\tiE~TCE~TER  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

MA.i\IAGE\tiE~TCE~TER MA.i\IAGE\tiE~TCE~TER NEPA DETERMINATION Page 1 of2 RECIPIENT:Brayton Energy STATE: MA PROJECT TITLE: High-Efficiency Low-Cost Solar Receiver for use in a Supercritical C02 Recompression Cycle Funding Opportunity Announcement Number Procurement Instrument Number NEPA Control Number CID Number DE-FOA-0000595 DE-EE0005799 GF0-0005799-{)01 G05799 Based on my review of the information concerning the proposed action, as NEPA Compliance Officer (authorized under DOE Order 451.1A), I have made the foUowing determination: CX, EA, EIS APPENDIX AND NUMBER: Description: A9 Information gathering, analysis, and dissemination Information gathering (including, 'but not limited to, literature surveys, inventories, site vrsits, and audits}, data analysis (including, but not limited to, computer modeling}, document preparation

413

EDeMa (Smart Grid Project) (Krefeld, Germany) | Open Energy Information  

Open Energy Info (EERE)

EDeMa (Smart Grid Project) (Krefeld, Germany) EDeMa (Smart Grid Project) (Krefeld, Germany) Jump to: navigation, search Project Name EDeMa Country Germany Headquarters Location Krefeld, Germany Coordinates 50.652943°, 6.339111° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":50.652943,"lon":6.339111,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

414

MA092 Geometria plana e analitica Comprimento da circunfer^encia -Area do circulo  

E-Print Network (OSTI)

MA092 ­ Geometria plana e anal´itica Comprimento da circunfer^encia - ´Area do c´irculo Francisco A) 51.758 voltas Francisco A. M. Gomes (UNICAMP - IMECC)MA092 ­ Geometria plana e anal´itica Setembro de´itica Setembro de 2014 5 / 14 ´Area do c´irculo C´irculo ´Area A ´area de um c´irculo de raio R ´e dada por AC

Gomes, Francisco A. M.

415

Data:32e71087-dc4e-4f67-a64d-c27cf8411705 | Open Energy Information  

Open Energy Info (EERE)

-dc4e-4f67-a64d-c27cf8411705 -dc4e-4f67-a64d-c27cf8411705 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: City of Rockwood, Tennessee (Utility Company) Effective date: 2012/12/01 End date if known: Rate name: Outdoor Lighting HPS 200w Sector: Lighting Description: ROCKWOOD ELECRIC UTILITY can install a private security light on your residential or commercial property under most conditions. All new requests for outdoor lighting require the applicant to sign a minimum two year contract for security lighting service. If you have security concerns and would like to discuss outdoor lighting options, please contact our Engineering Department to look at the situation with you.

416

Data:692a2dc0-44ed-44ef-a5d9-f42dc3f27436 | Open Energy Information  

Open Energy Info (EERE)

dc0-44ed-44ef-a5d9-f42dc3f27436 dc0-44ed-44ef-a5d9-f42dc3f27436 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Tri-County Elec Member Corp (Tennessee) Effective date: 2013/06/01 End date if known: Rate name: 400 Watt MV Sector: Lighting Description: Source or reference: http://www.tcemc.org/index.php/residential-information/ Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months): Service Voltage Minimum (V): Maximum (V): Character of Service Voltage Category: Phase Wiring: << Previous 1 2 3 Next >>

417

Data:5df914dc-748a-4757-980d-c7fa8bd9d9fe | Open Energy Information  

Open Energy Info (EERE)

dc-748a-4757-980d-c7fa8bd9d9fe dc-748a-4757-980d-c7fa8bd9d9fe No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Sumter Electric Member Corp Effective date: 2012/01/01 End date if known: Rate name: Outdoor Lighting Off- Roadway HPS 250 W Sector: Lighting Description: * Fixed Monthly Charge does not include monthly pole rate charges Source or reference: http://www.sumteremc.com/pdfs/OL-9.pdf Source Parent: Comments Applicability Demand (kW) Minimum (kW): Maximum (kW): History (months): Energy (kWh) Minimum (kWh): Maximum (kWh): History (months): Service Voltage Minimum (V): Maximum (V): Character of Service

418

Data:73d310b4-d5f4-48dc-b4dc-9aca99090e47 | Open Energy Information  

Open Energy Info (EERE)

0b4-d5f4-48dc-b4dc-9aca99090e47 0b4-d5f4-48dc-b4dc-9aca99090e47 No revision has been approved for this page. It is currently under review by our subject matter experts. Jump to: navigation, search Loading... 1. Basic Information 2. Demand 3. Energy << Previous 1 2 3 Next >> Basic Information Utility name: Village of Black Earth, Wisconsin (Utility Company) Effective date: 1999/08/01 End date if known: Rate name: Ms-1 Outdoor Lighting Service: Athletic Field Lighting Sector: Lighting Description: Application: This schedule will be applied to municipal street lighting. The utility will furnish, install, and maintain street lighting units. Fixed Monthly Charge includes Commitment to Community Rider: $1.33 per customer per month. Power Cost Adjustment Clause: Charge per all kWh varies monthly.

419

Research, Washington, DC (United States) Sandia National Labs.,  

Office of Scientific and Technical Information (OSTI)

584878 SAND--95-2914 GeoEnergy technology 1980-12-31 USDOE Office of Energy 584878 SAND--95-2914 GeoEnergy technology 1980-12-31 USDOE Office of Energy Research, Washington, DC (United States) Sandia National Labs., Albuquerque, NM (United States) English 2010-02-18 Technical Report http://www.osti.gov/geothermal/servlets/purl/584878-P1qAuZ/webviewable/ http://www.osti.gov/energycitations/product.biblio.jsp?osti_id=584878 29 ENERGY PLANNING AND POLICY; RESEARCH PROGRAMS; COAL; PETROLEUM; NATURAL GAS; SYNTHETIC PETROLEUM; GEOTHERMAL ENERGY; ENERGY CONVERSION; PRODUCTION; HEAT EXTRACTION; US DOE; IN-SITU GASIFICATION; ENHANCED RECOVERY; COAL LIQUEFACTION; GEOTHERMAL WELLS Geothermal Legacy 894529 894529 Use of Geothermal Energy for Aquaculture Purposes - Phase III Johnson, W.C.; Smith, K.C. 1981-09-01 USDOE Geo-Heat Center, Klamath Falls, OR English

420

Disc rotors with permanent magnets for brushless DC motor  

SciTech Connect

A brushless dc permanent magnet motor drives an autonomous underwater vehe. In one embodiment, the motor comprises four substantially flat stators in stacked relationship, with pairs of the stators axially spaced, each of the stators comprising a tape-wound stator coil, and first and second substantially flat rotors disposed between the spaced pairs of stators. Each of the rotors includes an annular array of permanent magnets embedded therein. A first shaft is connected to the first rotor and a second, concentric shaft is connected to the second rotor, and a drive unit causes rotation of the two shafts in opposite directions. The second shaft comprises a hollow tube having a central bore in which the first shaft is disposed. Two different sets of bearings support the first and second shafts. In another embodiment, the motor comprises two ironless stators and pairs of rotors mounted on opposite sides of the stators and driven by counterrotating shafts.

Hawsey, Robert A. (Oak Ridge, TN); Bailey, J. Milton (Knoxville, TN)

1992-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

FLUXCAP: A flux-coupled ac/dc magnetizing device  

E-Print Network (OSTI)

We report on an instrument for applying ac and dc magnetic fields by capturing the flux from a rotating permanent magnet and projecting it between two adjustable pole pieces. This can be an alternative to standard electromagnets for experiments with small samples or in probe stations in which an applied magnetic field is needed locally, with advantages that include a compact form-factor, very low power requirements and dissipation as well as fast field sweep rates. This flux capture instrument (FLUXCAP) can produce fields from -400 to +400 mT, with field resolution less than 1 mT. It generates static magnetic fields as well as ramped fields, with ramping rates as high as 10 T/s. We demonstrate the use of this apparatus for studying the magnetotransport properties of spin-valve nanopillars, a nanoscale device that exhibits giant magnetoresistance.

Gopman, Daniel B; Kent, Andrew D

2012-01-01T23:59:59.000Z

422

Prismatic Algorithm for Discrete D.C. Programming Problems  

E-Print Network (OSTI)

In this paper, we propose the first exact algorithm for minimizing the difference of two submodular functions (D.S.), i.e., the discrete version of the D.C. programming problem. The developed algorithm is a branch-and-bound-based algorithm which responds to the structure of this problem through the relationship between submodularity and convexity. The D.S. programming problem covers a broad range of applications in machine learning because this generalizes the optimization of a wide class of set functions. We empirically investigate the performance of our algorithm, and illustrate the difference between exact and approximate solutions respectively obtained by the proposed and existing algorithms in feature selection and discriminative structure learning.

Kawahara, Yoshinobu

2011-01-01T23:59:59.000Z

423

Effect of DC voltage pulses on memristor behavior.  

SciTech Connect

Current knowledge of memristor behavior is limited to a few physical models of which little comprehensive data collection has taken place. The purpose of this research is to collect data in search of exploitable memristor behavior by designing and implementing tests on a HP Labs Rev2 Memristor Test Board. The results are then graphed in their optimal format for conceptualizing behavioral patterns. This series of experiments has concluded the existence of an additional memristor state affecting the behavior of memristors when pulsed with positively polarized DC voltages. This effect has been observed across multiple memristors and data sets. The following pages outline the process that led to the hypothetical existence and eventual proof of this additional state of memristor behavior.

Evans, Brian R.

2013-10-01T23:59:59.000Z

424

Discharging a DC bus capacitor of an electrical converter system  

DOE Patents (OSTI)

A system and method of discharging a bus capacitor of a bidirectional matrix converter of a vehicle are presented here. The method begins by electrically shorting the AC interface of the converter after an AC energy source is disconnected from the AC interface. The method continues by arranging a plurality of switching elements of a second energy conversion module into a discharge configuration to establish an electrical current path from a first terminal of an isolation module, through an inductive element, and to a second terminal of the isolation module. The method also modulates a plurality of switching elements of a first energy conversion module, while maintaining the discharge configuration of the second energy conversion module, to at least partially discharge a DC bus capacitor.

Kajouke, Lateef A; Perisic, Milun; Ransom, Ray M

2014-10-14T23:59:59.000Z

425

Multi-terminal Subsystem Model Validation for Pacific DC Intertie  

SciTech Connect

this paper proposes to validate dynamic model of Pacific DC Intertie with the concept of hybrid simulation by combing simulation with PMU measurements. The Playback function available in GE PSLF is adopted for hybrid simulation. It is demonstrated for the first time the feasibility of using Playback function on multi-terminal subsystem. Sensitivity studies are also presented as a result of common PMU measurement quality problem, ie, offset noise and time synchronization. Results indicate a good tolerance of PDCI model generally. It is recommended that requirements should apply to phasor measurements in model validation work to ensure better analysis. Key parameters are identified based on impact of value change to model behavior. Two events are employed for preliminary model validation with PMU measurements. Suggestions are made for PDCI model validation work in the future.

Yang, Bo; Huang, Zhenyu; Kosterev, Dmitry

2008-07-20T23:59:59.000Z

426

EE443L: Intermediate Control Lab Lab2: Modeling a DC motor  

E-Print Network (OSTI)

will develop and validate a basic model of a permanent magnet DC motor (Yaskawa Electric, Mini-series, Minertia of a permanent magnet DC motor, the field current is constant (i.e. a constant magnetic field). It can be shown(t) = input voltage eb(t) = back emf if(t) = field current (t) = shaft angle (t) = torque J = moment

Wedeward, Kevin

427

High Dynamic Performance Programmed PWM Control of a Multilevel Inverter with Capacitor DC Sources  

E-Print Network (OSTI)

High Dynamic Performance Programmed PWM Control of a Multilevel Inverter with Capacitor DC Sources inverter consisting of a stan- dard 3-leg inverter supplied by a DC source and three full H-bridges each reactive voltage to the motor while the standard three leg inverter can supply both reactive and active

Tolbert, Leon M.

428

DC WRRC Report No. 127 GROUND WATER RESOURCE ASSESSMENT STUDY FOR  

E-Print Network (OSTI)

of the District of Columbia 4200 Connecticut Ave, NW Building 50, MB 5004 Washington, DC 20008 #12;ABSTRACT TITLE pollution on the District of Columbia's ground water. 'PROJECT STAFF *GOURND WATER RESOURCE ASSESSMENT STUDY Affairs Environmental Regulation Administration Water Resources Management Division Washington, DC 20020

District of Columbia, University of the

429

Superconducting Cables for a.c. and d.c. Power Transmission  

Science Journals Connector (OSTI)

...1973 research-article Superconducting Cables for a.c. and d.c. Power Transmission...power transmission lines. Some present cables are water cooled to increase their current...both a.c. and d.c. superconducting cables are described, with particular attention...

1973-01-01T23:59:59.000Z

430

A new technique to reject dc-link voltage ripple in PWM inverters  

E-Print Network (OSTI)

on the rlc-link, is numerically calculated. Let us assume, Inverfer output frequency f, ? 60 Hz Vs, = 1 pu Dc ? link voltage rrpple = k Vs, ? 0. 2 x Vge = . 2 pu Dc ? link voltage ripple frequency f, = 120 Hz :tfodulation index ? 0. 5 Frequency spectrum...

Shireen, Wajiha

1990-01-01T23:59:59.000Z

431

A nonlinear robust HVDC control for a parallel AC/DC power system  

E-Print Network (OSTI)

A nonlinear robust HVDC control for a parallel AC/DC power system Hongzhi Cai a , Zhihua Qu b. Keywords: Robust control; HVDC; Power system; Stability; Lyapunov method 1. Introduction It has been recognized that, through an HVDC transmission line, fast electronic control can be applied on the DC power

Qu, Zhihua

432

Exergy Analysis of Incremental Sheet Forming M.A. Dittrich1  

E-Print Network (OSTI)

Exergy Analysis of Incremental Sheet Forming M.A. Dittrich1 , T.G. Gutowski1 , J. Cao2 , J.T. Roth3 studied so far. Using the concept of exergy analysis, two ISF technologies, namely single sided and double. A second exergy analysis is carried out with the purpose of examining the environmental impact of different

Gutowski, Timothy

433

SoMaS Employability Strategy The School of Mathematics and Statistics will  

E-Print Network (OSTI)

SoMaS Employability Strategy The School of Mathematics and Statistics will: 10. Develop for the School's degrees with Employment Experience Our success will be measured by: · An increase of students switching to degrees with Employment Experience 11. enable students to gain skills through

Martin, Stephen John

434

LARGE DEXTRAL OFFSET ACROSS OWENS VALLEY, CALIFORNIA FROM 148 MA TO 1872 A.D.  

E-Print Network (OSTI)

Lake (Fig. 2) along a branch of the Owens Valley fault zone, and is well dis- played just west1 LARGE DEXTRAL OFFSET ACROSS OWENS VALLEY, CALIFORNIA FROM 148 MA TO 1872 A.D. Allen F. Glazner1 (estimated moment magnitude ~7.5) occurred in Owens Valley. Ground breakage extended from Big Pine to Owens

Lee, Jeff

435

Formblatt LM Ma Informatik Version Oktober 2012 Zuordnung von Lehrmodulen im Masterstudium Informatik  

E-Print Network (OSTI)

Formblatt LM Ma Informatik Version Oktober 2012 Zuordnung von Lehrmodulen im Masterstudium Komplexität Modul-Nr. Name (Kurzform) KP Note PR Programmierung LM 1 VI Verteilte Informationssysteme LM 2 PV Parallele und Vert. Systemarchitekturen LM 3 OC Organic Computing LM 4 IE Intelligente eingebettete Systeme

Lübeck, Universität zu

436

Formblatt LM Ma Informatik Version Mai 2010 Zuordnung von Lehrmodulen im Masterstudium Informatik  

E-Print Network (OSTI)

Formblatt LM Ma Informatik Version Mai 2010 Zuordnung von Lehrmodulen im Masterstudium Informatik-Nr.^+ KP LZF Note PR Programmierung LM 1 VI Verteilte Informationssysteme LM 2 PV Parallele und Vert. Systemarchitekturen LM 3 OC Organic Computing LM 4 IE Intelligente eingebettete Systeme Summe KP SB Signal- und

Lübeck, Universität zu

437

Trends in Multidisciplinary Engineering Education, MA&O 2006 Trends in Multidisciplinary Engineering  

E-Print Network (OSTI)

of the context in which engineering is practiced Economics (including business practice) History The environmentTrends in Multidisciplinary Engineering Education, MA&O 2006 Page 1 Trends in Multidisciplinary Engineering Education: 2006 and Beyond Awards Luncheon Olivier de Weck and Karen WillcoxOlivier de Weck

Peraire, Jaime

438

PHILOSOPHY (M.A. & Ph.D.) Executive Officer: Professor Iakovos Vasiliou  

E-Print Network (OSTI)

194 PHILOSOPHY (M.A. & Ph.D.) Executive Officer: Professor Iakovos Vasiliou The Graduate Center 365 Fifth Avenue New York, NY 10016 Email: Philosophy@gc.cuny.edu http://web.gc.cuny.edu/Philosophy/ facult Martin Tamny n Iakovos Vasiliou n Mary Bittman Wiseman the PrOgram The Graduate Program in Philosophy

Dennehy, John

439

M.T.Nair February 15 (2013, 2014) MA-5340: Measure and Integration  

E-Print Network (OSTI)

M.T.Nair February 15 (2013, 2014) MA-5340: Measure and Integration Assignment Sheet - II In the following, (X, A) is a measurable space. 1. Suppose (X, A) is a measurable space and X0 A. Then show measurable - Why? 4. Let (X, A, µ) is a measure space. Prove that, if is a non-negative real number, then E

Nair, M.Thamban

440

MA et al.: SKETCH RETRIEVAL VIA STROKE FEATURES 1 Sketch Retrieval via Dense Stroke Features  

E-Print Network (OSTI)

MA et al.: SKETCH RETRIEVAL VIA STROKE FEATURES 1 Sketch Retrieval via Dense Stroke Features Chao search method. In this paper, we propose a representation scheme which takes sketch strokes into account with local features, thereby facilitat- ing efficient retrieval with codebooks. Stroke features are detected

Yang, Ming-Hsuan

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

M. M. Oppenheim Y. S. Dimant, Boston University, Center for Space Physics, Boston, MA, 02215, USA  

E-Print Network (OSTI)

M. M. Oppenheim Y. S. Dimant, Boston University, Center for Space Physics, Boston, MA, 02215, USA Corresponding author Email addresses: meerso@bu.edu (M. M. Oppenheim), dimant@bu.edu (Y. S. Dimant). Preprint and Oppenheim. This paper begins with a general discussion of E-region irregularity observa- tions, theory

Oppenheim, Meers

442

Nanocrystals for Solar Energy MaRIE--A Facility in the Making  

E-Print Network (OSTI)

Nanocrystals for Solar Energy MaRIE--A Facility in the Making At the Chemical Movies 1663 LOS-secret laboratory was the mailing address--P. O. Box 1663, Santa Fe, New Mexico.That box number, still part of our Mexico, Los Alamos National Laboratory was founded in 1943 to build the first atomic bomb. It remains

443

The George R. Brown School of Engineering Degrees Offered: BA, MStat, MA, PhD  

E-Print Network (OSTI)

Probability and Statistics · STAT405 Statistical Computing and Graphics · STAT410Introduction to Statistical1 Statistics The George R. Brown School of Engineering Degrees Offered: BA, MStat, MA, PhD Course work in statistics acquaints students with the role played in the modern world by probabilistic

Richards-Kortum, Rebecca

444

The George R. Brown School of Engineering Degrees Offered: BA, MStat, MA, PhD  

E-Print Network (OSTI)

Introduction to Engineering Computation · STAT 310 Probability and Statistics · STAT 410 Introduction246 Statistics The George R. Brown School of Engineering Degrees Offered: BA, MStat, MA, PhD Course work in statistics acquaints students with the role played in the modern world by probabilistic

Richards-Kortum, Rebecca

445

The George R. Brown School of Engineering Degrees Offered: BA, MStat, MA, PhD  

E-Print Network (OSTI)

Introduction to Engineering Computation · STAT 310 Probability and Statistics · STAT 410 Introduction253 Statistics The George R. Brown School of Engineering Degrees Offered: BA, MStat, MA, PhD Course work in statistics acquaints students with the role played in the modern world by probabilistic

Richards-Kortum, Rebecca

446

POLITICAL SCIeNCe (M.A. & Ph.D.) Executive Officer: Professor Joe Rollins  

E-Print Network (OSTI)

206 POLITICAL SCIeNCe (M.A. & Ph.D.) Executive Officer: Professor Joe Rollins The Graduate Center 365 Fifth Avenue New York, NY 10016 Email: PoliticalScience@gc.cuny.edu http://www.gc.cuny.edu/Political Richard Wolin n Susan Woodward n Ming Xia n Donald Zagoria n Burton Zwiebach the PrOgram Political Science

Dennehy, John

447

Health & Medical Journalism Concentration: Grady College MA Non-Thesis Program Planning Form  

E-Print Network (OSTI)

Health & Medical Journalism Concentration: Grady College MA Non-Thesis Program Planning Form Methodology in Mass Communication 3. JRMC 7355 ( ) Health and Medical Journalism 4. JRMC 7356 ( ) Advanced Health and Medical Journalism Co-requisite for Concentration ­ for students with limited undergraduate

Arnold, Jonathan

448

John R. Harrison, Ph.D. 1978 B.A. Salem State College, Salem, MA Biology  

E-Print Network (OSTI)

1994 Stimulation of prostaglandin E2 production by interleukin-1 and transforming growth factorJohn R. Harrison, Ph.D. Education 1978 B.A. Salem State College, Salem, MA Biology 1986 Ph.D of recombinant transforming growth factor and interleukin-1 on DNA synthesis, collagen #12;synthesis, procollagen

Oliver, Douglas L.

449

Expansion of human pluripotent stem cells with synthetic oolymer PMVE-alt-MA  

E-Print Network (OSTI)

hESC hPSC ICM iPSC MEF MEF-CM PAA PBS PMVE-alt-MA qPCR RGD15 . Linear polyacrylic acid (pAA) chains were modified withpeptide-functionalized linear pAA chains were mixed and

Chu, Wai Keung

2011-01-01T23:59:59.000Z

450

Heliospheric current sheet inclinations at Venus and Earth G. Ma, K. Marubashi, and T. Maruyama  

E-Print Network (OSTI)

that the heliospheric current sheet inclination tends to be maintained during propagation of the solar wind from 0.72 AUHeliospheric current sheet inclinations at Venus and Earth G. Ma, K. Marubashi, and T. Maruyama / Revised: 16 September 1998 / Accepted: 22 October 1998 Abstract. We investigate the inclinations

Paris-Sud XI, Université de

451

Condensative Stream Query Language for Data Streams Lisha Ma1 Werner Nutt2 Hamish Taylor1  

E-Print Network (OSTI)

Condensative Stream Query Language for Data Streams Lisha Ma1 Werner Nutt2 Hamish Taylor1 1 School the answer to a similar non-aggregate query making query processing condensative. Cur- rent proposals for declarative query languages over data streams do not support such condensative pro- cessing. Nor is it yet

Taylor, Hamish

452

Condensing Effect of Palmitic Acid on DPPC in Mixed Langmuir Gang Ma and Heather C. Allen*  

E-Print Network (OSTI)

Condensing Effect of Palmitic Acid on DPPC in Mixed Langmuir Monolayers Gang Ma and Heather C in the liquid-expanded and condensed phases is explored. A condensing effect of PA on DPPC is observed with VSFG ordering of DPPC chains and causes DPPC to transition from the expanded phase into the condensed phase

453

Nano-mineralogy studies by advanced electron microscopy Chi Ma and George R. Rossman  

E-Print Network (OSTI)

Nano-mineralogy studies by advanced electron microscopy Chi Ma and George R. Rossman Division and planetary materials easier and faster down to nano-scales. Small but new minerals with important geological significance are being discovered. Nano-features are being discovered in many common minerals and gems, which

Ma, Chi

454

Washington DC Regions | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Washington DC Regions Washington DC Regions National Science Bowl® (NSB) NSB Home About High School Middle School Middle School Students Middle School Coaches Middle School Regionals Middle School Rules, Forms, and Resources Attending National Event Volunteers 2013 Competition Results News Media WDTS Home Contact Information National Science Bowl® U.S. Department of Energy SC-27/ Forrestal Building 1000 Independence Ave., SW Washington, DC 20585 P: 202-586-6702 E: National.Science.Bowl@science.doe.gov Middle School Regionals Washington DC Regions Print Text Size: A A A RSS Feeds FeedbackShare Page Washington, DC Coaches can review the middle school regional locations listed below. Please note: Registrations are based on the location of your school. Please be sure to select the regional that is designated for your

455

Washington DC Regions | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Washington DC Regions Washington DC Regions National Science Bowl® (NSB) NSB Home About High School High School Students High School Coaches High School Regionals High School Rules, Forms, and Resources Middle School Attending National Event Volunteers 2013 Competition Results News Media WDTS Home Contact Information National Science Bowl® U.S. Department of Energy SC-27/ Forrestal Building 1000 Independence Ave., SW Washington, DC 20585 P: 202-586-6702 E: National.Science.Bowl@science.doe.gov High School Regionals Washington DC Regions Print Text Size: A A A RSS Feeds FeedbackShare Page Washington, DC Coaches can review the high school regional locations listed below. Please note: Registrations are based on the location of your school. Please be sure to select the regional that is designated for your

456

D.C. Community Comes Together in the Name of Sustainability, Affordability  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

D.C. Community Comes Together in the Name of Sustainability, D.C. Community Comes Together in the Name of Sustainability, Affordability D.C. Community Comes Together in the Name of Sustainability, Affordability July 1, 2011 - 1:02pm Addthis Community leaders and members of the The New School for Design and Stevens Institute of Technology Solar Decathlon team.| Courtesy of Lisa Bleich Community leaders and members of the The New School for Design and Stevens Institute of Technology Solar Decathlon team.| Courtesy of Lisa Bleich Erin R. Pierce Erin R. Pierce Digital Communications Specialist, Office of Public Affairs What are the key facts? This 2011 Solar Decathlon team is partnering with D.C. community members and Habitat for Humanity to build an energy efficient home that will be moved to the Deanwood neighborhood of Washington, D.C. following

457

Harnessing the Power of the Sun, Solar Impulse Plane Lands in DC Area |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Harnessing the Power of the Sun, Solar Impulse Plane Lands in DC Harnessing the Power of the Sun, Solar Impulse Plane Lands in DC Area Harnessing the Power of the Sun, Solar Impulse Plane Lands in DC Area June 17, 2013 - 6:15pm Addthis Watch Energy Secretary Ernest Moniz give remarks at the Solar Impulse Press Conference in Washington, D.C. Erin R. Pierce Erin R. Pierce Digital Communications Specialist, Office of Public Affairs More on Solar Impulse View a slideshow of photos from today's event on Secretary Moniz's Facebook Page. Today, Secretary Moniz spoke at an event welcoming the arrival of the solar-powered Solar Impulse plane at Dulles International Airport near Washington, D.C. During the event, held at the National Air and Space Museum's Steven F. Udvar-Hazy Center, Secretary Moniz highlighted the rapid expansion of the solar industry in the United States over the past

458

Using Direct-DC Power Distribution in U.S. Residential Buildings Can Save  

NLE Websites -- All DOE Office Websites (Extended Search)

Using Direct-DC Power Distribution in U.S. Residential Buildings Can Save Using Direct-DC Power Distribution in U.S. Residential Buildings Can Save Energy October 2013 October-November Special Focus: Energy Efficiency, Buildings and the Electric Grid An increasing fraction of the most efficient appliances on the market operate on direct current (DC) internally, making it possible to use DC from renewable energy systems directly and avoid the losses inherent in converting power to alternating current (AC) and back, as is current practice. Products are also emerging on the commercial market that take advantage of that possibility. Lawrence Berkeley National Laboratory researchers Vagelis Vossos, Karina Garbesi, and Hongxia Shen investigated the potential savings of direct-DC power distribution in net-metered residences with on-site photovoltaics

459

2D Joint Inversion Of Dc And Scalar Audio-Magnetotelluric Data In The  

Open Energy Info (EERE)

Joint Inversion Of Dc And Scalar Audio-Magnetotelluric Data In The Joint Inversion Of Dc And Scalar Audio-Magnetotelluric Data In The Evaluation Of Low Enthalpy Geothermal Fields Jump to: navigation, search GEOTHERMAL ENERGYGeothermal Home Journal Article: 2D Joint Inversion Of DC And Scalar Audio-Magnetotelluric Data In The Evaluation Of Low Enthalpy Geothermal Fields Details Activities (0) Areas (0) Regions (0) Abstract: Audio-magnetotelluric (AMT) and resistivity (dc) surveys are often used in environmental, hydrological and geothermal evaluation. The separate interpretation of those geophysical data sets assuming two-dimensional models frequently produces ambiguous results. The joint inversion of AMT and dc data is advocated by several authors as an efficient method for reducing the ambiguity inherent to each of those

460

Persons Who Received the DC PSC's Emergency Petition and Complaint via  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Persons Who Received the DC PSC's Emergency Petition and Complaint Persons Who Received the DC PSC's Emergency Petition and Complaint via E-mail on August 24, 2005 Persons Who Received the DC PSC's Emergency Petition and Complaint via E-mail on August 24, 2005 Docket No. EO-05-01: In response to your August 29, 2005 letter, attached please find a list of all entities and organizations to whom we served the District of Columbia Public Service Commission's (HOC PSC") Petition and Complaint filed on August 24, 2005, in the above-referenced proceeding. In addition, attached is the Federal Energy Regulatory Conmlission ("FERC") service list which contains some additional entities that have intervened before the FERC and that have apparently viewed the DC PSC's Petition and Complaint. Persons Who Received the DC PSC's Emergency Petition and Complaint via

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Grid Modernization Highlighted in Washington DC in September with the Solar  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Grid Modernization Highlighted in Washington DC in September with Grid Modernization Highlighted in Washington DC in September with the Solar Decathlon Grid Modernization Highlighted in Washington DC in September with the Solar Decathlon September 9, 2011 - 4:40pm Addthis Smart Grid is on display at the U.S. Department of Energy 2011 Solar Decathlon, held September 23 through October 2 on the National Mall, West Potomac Park, Washington, DC. The decathlon challenges collegiate teams to design, build, and operate solar-powered houses that are cost-effective, energy-efficient, and attractive. The Office of Electricity Delivery and Energy Reliability will be hosting a booth providing information on grid modernization and smart meters. From Monday September 12 through Thursday September 15, the GridWeek conference was held in Washington, DC. The Office of Electricity Delivery

462

We Have a Winner - DC High School Regional Science Bowl Competition Held  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

We Have a Winner - DC High School Regional Science Bowl Competition We Have a Winner - DC High School Regional Science Bowl Competition Held Last Saturday We Have a Winner - DC High School Regional Science Bowl Competition Held Last Saturday February 11, 2013 - 10:30am Addthis We Have a Winner - DC High School Regional Science Bowl Competition Held Last Saturday Annie Whatley Annie Whatley Deputy Director, Office of Minority Economic Impact As part of the National Science Bowl, more than 9,500 high school students take place in 70 high school regional competitions around the United States and Puerto Rico. The winners of these regions advance to the National Science Bowl competition held every April in Chevy Chase, Maryland. On Saturday, February 9, the Office of Economic Impact and Diversity hosted the Washington, D.C. High School Regional Science Bowl competition at Cesar

463

Small wind turbine emulator with armature controlled separately excited DC motor via analogue electronic circuit  

Science Journals Connector (OSTI)

In this paper, a small wind turbine emulator (WTE) using separately excited DC motor is modelled, designed, simulated, implemented and tested. A 1 HP separately excited DC motor is used to emulate the characteristics of the rotor of small wind turbine. The DC motor is driven by a thyristor bridge with closed-loop cascaded PI controller for armature control. A separately excited DC generator with a variable resistive load is directly coupled to the DC motor. A small cheap analogue electronic circuit, with less interfacing, is used to generate a specific reference wind turbine speed based on the wind turbine rotor characteristics and the mechanical wind power available. Simulation and experimental results are compared to proof the validity and accuracy of the WTE.

A. Mahdy; S.M. El-Hakim; Hanafy Hassan Hanafy

2012-01-01T23:59:59.000Z

464

Adaptive Selective Harmonic Minimization Based on ANNs for Cascade Multilevel Inverters With Varying DC Sources  

SciTech Connect

A new approach for modulation of an 11-level cascade multilevel inverter using selective harmonic elimination is presented in this paper. The dc sources feeding the multilevel inverter are considered to be varying in time, and the switching angles are adapted to the dc source variation. This method uses genetic algorithms to obtain switching angles offline for different dc source values. Then, artificial neural networks are used to determine the switching angles that correspond to the real-time values of the dc sources for each phase. This implies that each one of the dc sources of this topology can have different values at any time, but the output fundamental voltage will stay constant and the harmonic content will still meet the specifications. The modulating switching angles are updated at each cycle of the output fundamental voltage. This paper gives details on the method in addition to simulation and experimental results.

Filho, Faete [ORNL; Maia, Helder Z [UFMS, Department of Electrical Engineering; Mateus, Tiago Henrique D [ORNL; Ozpineci, Burak [ORNL; Tolbert, Leon M [ORNL; Pinto, Joao Onofre P [ORNL

2013-01-01T23:59:59.000Z

465

Harnessing the Power of the Sun, Solar Impulse Plane Lands in DC Area |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Harnessing the Power of the Sun, Solar Impulse Plane Lands in DC Harnessing the Power of the Sun, Solar Impulse Plane Lands in DC Area Harnessing the Power of the Sun, Solar Impulse Plane Lands in DC Area June 17, 2013 - 6:15pm Addthis Watch Energy Secretary Ernest Moniz give remarks at the Solar Impulse Press Conference in Washington, D.C. Erin R. Pierce Erin R. Pierce Digital Communications Specialist, Office of Public Affairs More on Solar Impulse View a slideshow of photos from today's event on Secretary Moniz's Facebook Page. Today, Secretary Moniz spoke at an event welcoming the arrival of the solar-powered Solar Impulse plane at Dulles International Airport near Washington, D.C. During the event, held at the National Air and Space Museum's Steven F. Udvar-Hazy Center, Secretary Moniz highlighted the rapid expansion of the solar industry in the United States over the past

466

Sustainable Energy Utility - D.C. Home Performance (District of Columbia) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

D.C. Home Performance (District of D.C. Home Performance (District of Columbia) Sustainable Energy Utility - D.C. Home Performance (District of Columbia) < Back Eligibility Multi-Family Residential Residential Savings Category Other Program Info Start Date 06/14/2012 State District of Columbia Program Type Utility Rebate Program Rebate Amount $500 The District of Columbia Sustainable Energy Utility currently offers the D.C. Home Performance program (DCHP). DCHP provides a $500 incentive to properties which successfully complete qualifying home energy upgrades. This incentive is available to D.C. residents living in single-family homes, rowhomes (each unit is ground to sky) or converted (1 to 4 unit) apartments and rowhomes. Both owner-occupied homes and rental properties with the property owners' authorization are eligible to participate.

467

Dieckmann U & Ferrire R (2004). Adaptive Dynamics and Evolving Biodiversity. In: Evolutionary Conservation Biology, eds. Ferrire R, Dieckmann U & Couvet D, pp. 188224. Cambridge University  

E-Print Network (OSTI)

Dieckmann U & Ferrière R (2004). Adaptive Dynamics and Evolving Biodiversity. In: Evolutionary Conservation Biology, eds. Ferrière R, Dieckmann U & Couvet D, pp. 188­224. Cambridge University Press. c International Institute for Applied Systems Analysis 11 Adaptive Dynamics and Evolving Biodiversity Ulf

Dieckmann, Ulf

468

J. Plasma Physics (2002), vol. 68, part 2, pp. 87117. " 2002 Cambridge University Press DOI: 10.1017/S0022377802001861 Printed in the United Kingdom  

E-Print Network (OSTI)

J. Plasma Physics (2002), vol. 68, part 2, pp. 87­117. " 2002 Cambridge University Press DOI: 10 passes through multiple stages of evolution in which the electric field amplitude is not simply predicted boundary, as measured by a suitable control parameter, (proportional to the growth rate). Two

Balmforth, Neil

469

J. Fluid Mech. (2003), vol. 485, pp. 307335. c 2003 Cambridge University Press DOI: 10.1017/S0022112003004518 Printed in the United Kingdom  

E-Print Network (OSTI)

with bias flow By JEFF D. ELDREDGE AND ANN P. DOWLING Department of Engineering, University of Cambridge Williams (1972). Leppington & Levine (1973) performed the same analysis with the help of an integral equation, which allowed a correction to the Ffowcs Williams result. They also considered the case when

Eldredge, Jeff

470

Journal of Tropical Ecology (2007) 23:715719. Copyright 2007 Cambridge University Press doi:10.1017/S0266467407004440 Printed in the United Kingdom  

E-Print Network (OSTI)

Journal of Tropical Ecology (2007) 23:715­719. Copyright © 2007 Cambridge University Press doi:10, multi-trophic interactions, Theobroma cacao In the Neotropics, crops that are grown in agroforestry systems with shade trees support high levels of bird diversity compared with crops grown without shade

Bermingham, Eldredge

471

Development of ITER 15 MA ELMy H-mode Inductive Scenario  

SciTech Connect

The poloidal field (PF) coil system on ITER, which provides both feedforward and feedback control of plasma position, shape, and current, is a critical element for achieving mission performance. Analysis of PF capabilities has focused on the 15 MA Q = 10 scenario with a 300-500 s flattop burn phase. The operating space available for the 15 MA ELMy H-mode plasma discharges in ITER and upgrades to the PF coils or associated systems to establish confidence that ITER mission objectives can be reached have been identified. Time dependent self-consistent free-boundary calculations were performed to examine the impact of plasma variability, discharge programming, and plasma disturbances. Based on these calculations a new reference scenario was developed based upon a large bore initial plasma, early divertor transition, low level heating in L-mode, and a late H-mode onset. Equilibrium analyses for this scenario indicate that the original PF coil limitations do not allow low li (<0.8) operation or lower flux states, and the flattop burn durations were predicted to be less than the desired 400 s. This finding motivates the expansion of the operating space, considering several upgrade options to the PF coils. Analysis was also carried out to examine the feedback current reserve required in the CS and PF coils during a series of disturbances and a feasibility assessment of the 17 MA scenario was undertaken. Results of the studies show that the new scenario and modified PF system will allow a wide range of 15 MA 300-500 s operation and more limited but finite 17 MA operation.

Kessel, C. E.; Campbell, D.; Gribov, Y.; Saibene, G.; Ambrosino, G.; Casper, T.; Cavinato, M.; Fujieda, H.; Hawryluk, R.; Horton, L. D.; Kavin, A.; Kharyrutdinov, R.; Koechl, F.; Leuer, J.; Loarte, A.; Lomas, P. J.; Luce, T.; Lukash, V.; Mattei, M.; Nunes, I.; Parail, V.; Polevoi, A.; Portone, A.; Sartori, R.; Sips, A. C.C.; Thomas, P. R.; Welander, A.; Wesley, J.

2008-10-16T23:59:59.000Z

472

High energy electron fluxes in dc-augmented capacitively coupled plasmas I. Fundamental characteristics  

SciTech Connect

Power deposition from electrons in capacitively coupled plasmas (CCPs) has components from stochastic heating, Joule heating, and from the acceleration of secondary electrons through sheaths produced by ion, electron, or photon bombardment of electrodes. The sheath accelerated electrons can produce high energy beams which, in addition to producing excitation and ionization in the gas can penetrate through the plasma and be incident on the opposite electrode. In the use of CCPs for microelectronics fabrication, there may be an advantage to having these high energy electrons interact with the wafer. To control the energy and increase the flux of the high energy electrons, a dc bias can be externally imposed on the electrode opposite the wafer, thereby producing a dc-augmented CCP (dc-CCP). In this paper, the characteristics of dc-CCPs will be discussed using results from a computational study. We found that for a given rf bias power, beams of high energy electrons having a narrow angular spread (<1 deg. ) can be produced incident on the wafer. The maximum energy in the high energy electron flux scales as {epsilon}{sub max}=-V{sub dc}+V{sub rf}+V{sub rf0}, for a voltage on the dc electrode of V{sub dc}, rf voltage of V{sub rf}, and dc bias on the rf electrode of V{sub rf0}. The dc current from the biased electrode must return to ground through surfaces other than the rf electrode and so seeks out a ground plane, typically the side walls. If the side wall is coated with a poorly conducting polymer, the surface will charge to drive the dc current through.

Wang Mingmei [Department of Chemical and Biological Engineering, Iowa State University, Ames, Iowa 50010 (United States); Kushner, Mark J. [Department of Electrical Engineering and Computer Science, University of Michigan, 1301 Beal Ave., Ann Arbor, Michigan 48109 (United States)

2010-01-15T23:59:59.000Z

473

Third-order gas-liquid phase transition and the nature of Andrews critical Tian Ma and Shouhong Wang  

E-Print Network (OSTI)

Third-order gas-liquid phase transition and the nature of Andrews critical point Tian Ma-order gas-liquid phase transition and the nature of Andrews critical point Tian Ma1 and Shouhong Wang2 1 is to study the nature of the Andrews critical point in the gas-liquid transition in a physical

Wang, Shouhong

474

MA 13700  

E-Print Network (OSTI)

Course Coordinator: Renee Roames; ph: 494-1929; office: MATH 808; email: rroames@purdue.edu; Instructor: Gabe Smith; email: smith522@math.purdue.

475

Ma Philippine  

Office of Scientific and Technical Information (OSTI)

and elec. eqpmt." Garments and texti lesb Coppernickeli ron ore Bananasraw coffee Fish and processed food Chemical s Other nontraditional Traditional exports Coconut...

476

MA 16100  

E-Print Network (OSTI)

Course Info. Syllabus Emergency Preparedness Syllabus Attachment Course Calendar Assignment Sheet. Resources. Online Graphing Calculator Past...

477

- MA 162  

E-Print Network (OSTI)

Sep 18, 2014 ... |G1|GZ|G3|G4|G1 |selsrlmlmlciolculclz G11 G14 615 cm mmmwml amiable Slripiabie _ mmmmm F S'p I .H_er R s mmmmmm. ' F ' F surname...

478

MA 265  

E-Print Network (OSTI)

Sections; 265 01 01 MWF 8:30 REC 113 Wang,Yanqiu 820; 265 02 01 MWF 9:30 REC 113 Wang,Yanqiu 820; 265 03 01 MWF 10:30 REC 113 Smith,Jeffrey H...

479

MA 13900  

E-Print Network (OSTI)

Gabe Smith; office: MATH B13; Mondays/Wednesdays 12:30-1:30; Lee Coduti; office: MATH B13; Mondays/Fridays 2:30-3:30; Renee Roames; office: MATH 808

480

MA 166  

E-Print Network (OSTI)

... MATH 175 Cook,Peter W 846; 166 01 01 Th 7:30 EE 236 Wilkins,Jeffrey 739 ... 236 Chen,Lung-Hui 609; 166 11 01 Th 7:30 PHYS 331 Kravitz,Benjamin 743...

Note: This page contains sample records for the topic "dc cambridge ma" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

MA 22000  

E-Print Network (OSTI)

Academic Integrity Policy Campus Emergency Policy Changing Sections; Lesson Notes; Lesson 26 Lesson 27 Lesson 28 Lesson 29 Lesson 30 Lesson...

482

Tammy Ma  

NLE Websites -- All DOE Office Websites (Extended Search)

step toward ignition or alpha heating (where the fusion reactions start to become self-sustaining) or another mission-based project. Together, we'll come up with an idea for an...

483

MA 16021  

E-Print Network (OSTI)

Applied Calculus II And Differential Equations ... Techniques of integration and applications to technology problems such as work and fluid pressure; infinite...

484

MA 22100  

E-Print Network (OSTI)

Calculus For Technology I ... Emergency procedures ... a two-semester sequence in the technique of calculus for students enrolled in certain technical curricula.

485

MA 15300  

E-Print Network (OSTI)

PowerPoints, Video Lessons and Outlines Supplemental Instruction Info Tutoring/Assistance Opportunities Chapter 1 of Textbook Even Answers to Book...

486

MA 182  

E-Print Network (OSTI)

... Midterm Exam 2 Solutions Practice Exam Midterm Exam 1 Continuity facts Limits of increasing sequences and the LUB axiom Floating space tool...

487

Ma Philippine  

Office of Scientific and Technical Information (OSTI)

4 I s Sea PHILIPPINES 7 ; : : ' - ,. * . DE89 007772 PHILIPPINES Asia Pacific Energy Series Country Report DISCLAIMER This report was prepared as an account of work...

488

MA 52300  

E-Print Network (OSTI)

... of linear equations; equations of mathematical physics; study of Laplace, wave and heat equations; methods of solution. Typically offered Fall Spring Summer.

489

MA 262  

E-Print Network (OSTI)

It is of important interest in controls systems, electrical engineering, physics, nuclear engineering, etc. For example, suppose one determines the equations...

490

MA Doping Analysis on Breeding Capability and Protected Plutonium Production of Large FBR  

SciTech Connect

Spent fuel from LWR can be seen as long-live waste if it is not recycled or as a 'new fuel' resource if it is recycled into the reactors. Uranium and plutonium have been used for 'new fuel' resources from LWR spent fuel as MOX fuel type which is loaded into thermal reactor or fast reactor types. Other actinides from the spent fuel such as neptunium, americium and curium as minor actinide (MA) are considered to be loaded into the reactors for specific purposes, recently. Those purposes such as for increasing protected plutonium production and breeding capability for protected plutonium as well as in the same time those amount of MA can be reduced to a small quantity as a burner or transmutation purpose. Some investigations and scientific approaches are performed in order to increase a material ''barrier'' in plutonium isotope composition by increasing the even mass number of plutonium isotope such as Pu-238, Pu-240 and Pu-242 as plutonium protected composition. Higher material barrier which related to intrinsic properties of plutonium isotopes with even mass number (Pu-238, Pu-240 and Pu-242), are recognized because of their intense decay heat (DH) and high spontaneous fission neutron (SFN) rates. Those even number mass of plutonium isotope contribute to some criteria of plutonium characterization which will be adopted for present study such as IAEA, Pellaud and Kessler criteria (IAEA, 1972; Pellaud, 2002; and Kessler, 2007). The present paper intends to evaluate the breeding capability as a fuel sustainability index of the reactors and to analyze the composition of protected plutonium production of large power reactor based on the FaCT FBR as reference (Ohki, et al., 2008). Three dimensional FBR core configuration has been adopted which is based on the core optimization calculation of SRAC-CITATION code as reactor core analysis and JENDL-3.3 is adopted for nuclear data library. Some MA doping materials are loaded into the blanket regions which can be considered as breeding region for protected plutonium production. Breeding capability of the reactor can be increased effectively by increasing MA doping rate while criticality condition of the reactor is reduced by doping MA. Adopting MA cycle is also effective to increase the isotopic Pu-238 production in plutonium vector composition for denaturing purpose of plutonium.

Permana, Sidik; Suzuki, Mitsutoshi; Kuno, Yusuke [Japan Atomic Energy Agency, Nuclear Non-proliferation Science and Technology Center, 2-4 Shirane Shirakata, Tokai-mura, Ibaraki, 319-1195 (Japan)

2010-06-22T23:59:59.000Z

491

Solar Decathlon at Home in the D.C. Community | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

at Home in the D.C. Community at Home in the D.C. Community Solar Decathlon at Home in the D.C. Community Addthis A New Energy-Efficient Home in the D.C. Community 1 of 27 A New Energy-Efficient Home in the D.C. Community On December 4, 2012, the Empowerhouse team, along with partners and community members, completed the installation of a permanent, two-family home in Washington, D.C. The home was originally showcased as part of the U.S Department of Energy's Solar Decathlon 2011. Image: Sarah Gerrity Date taken: 2012-12-04 12:22 2 of 27 The house is located in the D.C. neighborhood of Deanwood, which is just 10 miles from the National Mall. By installing the house nearby, the team was able to minimize shipping costs, therefore reducing the house's carbon footprint. Image: Sarah Gerrity Date taken: 2012-12-04 09:00

492

Photosynthetic electron partitioning between [FeFe]-hydrogenase and ferredoxin:NADP+-oxidoreductase (FNR) enzymes in vitro  

Science Journals Connector (OSTI)

...Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA...efficient conversion of solar energy into hydrogen in atmospheric...Engineering NE47-379, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA...

Iftach Yacoby; Sergii Pochekailov; Hila Toporik; Maria L. Ghirardi; Paul W. King; Shuguang Zhang

2011-01-01T23:59:59.000Z

493

Learning Hierarchical Plans by Reading Simple English Dustin Smith  

E-Print Network (OSTI)

Learning Hierarchical Plans by Reading Simple English Narratives Dustin Smith MIT Media Lab Cambridge, MA USA dsmit@mit.edu Kenneth Arnold MIT Media Lab Cambridge, MA USA kcarnold@mit.edu ABSTRACT We

Herr, Hugh

494

Energy savings from direct-DC in U.S. residential buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

savings from direct-DC in U.S. residential buildings savings from direct-DC in U.S. residential buildings Title Energy savings from direct-DC in U.S. residential buildings Publication Type Journal Article Year of Publication 2013 Authors Vossos, Vagelis, Karina Garbesi, and Hongxia Shen Journal Energy and Buildings Volume Volume 68, Part A Pagination 223-231 Date Published 09/2013 Keywords Direct current (DC), energy conservation, Photovoltaics (PV), residential buildings Abstract An increasing number of energy-efficient appliances operate on direct current (DC) internally, offering the potential to use DC directly from renewable energy systems, thereby avoiding the energy losses inherent in converting power to alternating current (AC) and back. This paper investigates that potential for net-metered residences with on-site photovoltaics (PV) by modeling the net power draw of a 'direct-DC house' compared to that of a typical net-metered house with AC distribution, assuming identical DC-internal loads. The model comparisons were run for 14 cities in the United States, using hourly, simulated PV-system output and residential loads. The model tested the effects of climate and battery storage. A sensitivity analysis was conducted to determine how future changes in the efficiencies of power system components might affect potential energy savings. Based on this work, we estimate that net-metered PV residences could save 5% of their total electricity load for houses without storage and 14% for houses with storage. Direct-DC energy savings are sensitive to power system and appliance conversion efficiencies but are not significantly influenced by climate.

495

Impact of quasi-dc currents on three-phase distribution transformer installations  

SciTech Connect

This report summarizes a series of tests designed to determine the response of quasi-dc currents on three-phase power distribution transformers for electric power systems. In general, if the dc injection is limited to the primary side of a step-down transformer, significant harmonic distortion is noted and an increase in the reactive power demand results. For dc injection on the secondary (load) side of the step-down transformer the harmonic content at the secondary side is quite high and saturation occurs with a relatively low level of dc injection; however, the reactive power demand is significantly lower. These tests produced no apparent damage to the transformers. Transformer damage is dependent on the duration of the dc excitation, the level of the excitation, and on thermal characteristics of the transfer. The transformer response time is found to be much shorter than seen in power transformer tests at lower dc injection levels. This shorter response time suggests that the response time is strongly dependent on the injected current levels, and that higher levels of dc injection for shorter durations could produce very high reactive power demands and harmonic distortion within a few tenths of a second. The added reactive power load could result in the blowing of fuses on the primary side of the transformer for even moderate dc injection levels, and neutral currents are quite large under even low-level dc injection. This smoking neutral'' results in high-level harmonic injection into equipment via the neutral and in possible equipment failure.

McConnell, B.W.; Barnes, P.R. (Oak Ridge National Lab., TN (United States)); Tesche, F.M. (Tesche (F.M.), Dallas, TX (United States)); Schafer, D.A. (Mission Research Corp., Albuquerque, NM (United States))

1992-06-01T23:59:59.000Z

496

Observation and cancellation of the dc Stark shift in strontium optical lattice clocks  

E-Print Network (OSTI)

We report on the observation of a dc Stark frequency shift at the $10^{-13}$ level by comparing two strontium optical lattice clocks. This frequency shift arises from the presence of electric charges trapped on dielectric surfaces placed under vacuum close to the atomic sample. We show that these charges can be eliminated by shining UV light on the dielectric surfaces, and characterize the residual dc Stark frequency shift on the clock transition at the $10^{-18}$ level by applying an external electric field. This study shows that the dc Stark shift can play an important role in the accuracy budget of lattice clocks, and should be duly taken into account.

Lodewyck, Jrme; Lorini, Luca; Gurov, Mikhail; Lemonde, Pierre

2011-01-01T23:59:59.000Z

497

Application of direct pulsewidth modulation scheme to AC-DC converters: - a way to reduce ripple  

E-Print Network (OSTI)

and Problems . 2 Switching Transfer Function . 3 General Theory of PWM 4 Performance Measurement of PWM sc-dc Coverters 1 5 8 12 ALGORITHM OF DIRECT PULSEWIDTH MODULATION USED IN AC- DC COVERTER 14 SINGLE PHASE AC-DC PWM CONVERTERS . . 17 ac..., and ISPWM. 3. 1 Sinusoidal Pulsewidth Modulation (SPWM) SPWM is the most commonly used PWM technique. In SPWM as shown in Figure 1, the pulse widths are generated by comparing a carrier signal which is made of CARRIER REFERENCE 0 0 I . 0 1. 5 20 2. 5...

Zhang, Yuemin

2012-06-07T23:59:59.000Z

498

The smoothing transformer, a new concept in dc side harmonic reduction of HVdc schemes  

SciTech Connect

Direct connection schemes have been a subject of recent investigation, offering operational flexibility and substantial reductions in ac components. In these schemes the use of active dc filters has been suggested to replace the conventional tuned passive filter design. This paper presents the smoothing transformer as a new means for reducing dc harmonics at characteristic and non-characteristic frequencies using only passive components. A realistic smoothing transformer design is examined using the New Zealand HVdc system operating in the direct connection mode. The steady-state and transient performance of the smoothing transformer design is compared with that of the existing dc smoothing reactor and filter bank.

Enright, W.; Arrillaga, J.; Wood, A.R.; Hidalgo, F.P.

1996-10-01T23:59:59.000Z

499

u.s. DEPARTIIIENT OF ENERGY EERE PROJECT MA N A GE M E~ T CENT  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

MA N A GE M E~ T CENT MA N A GE M E~ T CENT ER NEPA DETERlIlINATION Page 1 of2 RECIPIENT:Power Environmental Energy Research Institute STATE: CO PROJECT TITLE: Novel Multidimensional Tracers for Geolhermallnter-Well Diagnostics Funding Opportunity Announcement Number DE-PS36-09G099018 Procurement Instrument Number OE·EEOOO3032 NEPA Control Number GFO-1 0-345 CID Number G03032 Based on my review orlhe Information concerning the proposed action, as NEPA Compliance Officer (authoriud under DOE Order 4SI.IA),1 have made the following determination: ex, EA, [IS APPENDIX AND NUMBER: Description: 83.1 Onsile and offsite site characterization and environmental monitoring. including siting, construction (or modification), operation, and dismantlement or closing (abandonment) of characterization and monitoring devices and siting,

500

MHK Projects/GCK Technology Cape Cod Canal MA US | Open Energy Information  

Open Energy Info (EERE)

GCK Technology Cape Cod Canal MA US GCK Technology Cape Cod Canal MA US < MHK Projects Jump to: navigation, search << Return to the MHK database homepage Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":5,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"500px","height":"350px","centre":false,"title":"","label":"","icon":"File:Aquamarine-marker.png","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":41.7433,"lon":-70.6093,"alt":0,"address":"","icon":"http:\/\/prod-http-80-800498448.us-east-1.elb.amazonaws.com\/w\/images\/7\/74\/Aquamarine-marker.png","group":"","inlineLabel":"","visitedicon":""}]}