Powered by Deep Web Technologies
Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Lighting system combining daylight concentrators and an artificial source  

DOE Patents [OSTI]

A combined lighting system for a building interior includes a stack of luminescent solar concentrators (LSC), an optical conduit made of preferably optical fibers for transmitting daylight from the LSC stack, a collimating lens set at an angle, a fixture for receiving the daylight at one end and for distributing the daylight as illumination inside the building, an artificial light source at the other end of the fixture for directing artifical light into the fixture for distribution as illumination inside the building, an automatic dimmer/brightener for the artificial light source, and a daylight sensor positioned near to the LSC stack for controlling the automatic dimmer/brightener in response to the daylight sensed. The system also has a reflector positioned behind the artificial light source and a fan for exhausting heated air out of the fixture during summer and for forcing heated air into the fixture for passage into the building interior during winter.

Bornstein, Jonathan G. (Miami, FL); Friedman, Peter S. (Toledo, OH)

1985-01-01T23:59:59.000Z

2

MODELING, SIMULATION AND OPTIMIZATION OF GROUND SOURCE  

E-Print Network [OSTI]

MODELING, SIMULATION AND OPTIMIZATION OF GROUND SOURCE HEAT PUMP SYSTEMS By MUHAMMAD HAIDER KHAN AND OPTIMIZATION OF GROUND SOURCE HEAT PUMP SYSTEMS Thesis Approved..................................................................................................................... 1 1.1 Overview of Ground Source Heat Pump Systems.............................................. 1 1

3

IMPLEMENTING GROUND SOURCE HEAT PUMP AND GROUND LOOP HEAT EXCHANGER  

E-Print Network [OSTI]

IMPLEMENTING GROUND SOURCE HEAT PUMP AND GROUND LOOP HEAT EXCHANGER MODELS IN THE ENERGYPLUS #12;ii IMPLEMENTING GROUND SOURCE HEAT PUMP AND GROUND LOOP HEAT EXCHANGER MODELS IN THE ENERGYPLUS............................................................... 2 1.3. Overview of the Parameter Estimation Water-to-Water Heat Pump Model ........... 5 1

4

THE DAYLIGHTING SOLUTION  

E-Print Network [OSTI]

of modulating sunlight and daylight. By intercepting directto the building owner. Daylight and sunlight have alwaysuse. While the use of daylight in homes is not seen as a

Selkowitz, Stephen

2013-01-01T23:59:59.000Z

5

MODELING OF VERTICAL GROUND LOOP HEAT EXCHANGERS FOR GROUND SOURCE  

E-Print Network [OSTI]

MODELING OF VERTICAL GROUND LOOP HEAT EXCHANGERS FOR GROUND SOURCE HEAT PUMP SYSTEMS By CENK SOURCE HEAT PUMP SYSTEMS Thesis Approved: ___________________________________________ Thesis Adviser scale test data. The short-term behavior of ground-coupled heat pump systems is important for the design

6

North Village Ground Source Heat Pumps  

Broader source: Energy.gov [DOE]

Overview: Installation of Ground Source Heat Pumps. Replacement of Aging Heat Pumps. Alignment with Furmans Sustainability Goals.

7

Daylighting Calculation in DOE-2  

E-Print Network [OSTI]

4 2.3 Daylight46 3.2.1 Exterior Daylight Availabilityof Interior Daylight Illuminance . . . . . . . . . . ..21

Winkelmann, F.C

2013-01-01T23:59:59.000Z

8

High-Efficiency Solar Cogeneration with TPV & Fiber-Optic Daylighting...  

Broader source: Energy.gov (indexed) [DOE]

High-Efficiency Solar Cogeneration with TPV & Fiber-Optic Daylighting High-Efficiency Solar Cogeneration with TPV & Fiber-Optic Daylighting Lead Performer: Creative Light Source,...

9

THE DAYLIGHTING SOLUTION  

E-Print Network [OSTI]

1980, pp.l4-20 THE DAYLIGHTING SOLUTION Stephen SelkowitzEEB-W·-80-19 W-74 THE DAYLIGHTING SOLUTION Stephen Selkowitz

Selkowitz, Stephen

2013-01-01T23:59:59.000Z

10

MANDATORY MEASURES DAYLIGHTING  

E-Print Network [OSTI]

MANDATORY MEASURES DAYLIGHTING Reference: Sub-Chapter 4, Section 130.1(d) #12;SECTION 4 Daylighting daylighting controls. · Lighting in daylit zones should have multi-level steps, per Table 130.1-A · Light levels provided at night should be available at all other times · When sufficient daylight is available

California at Davis, University of

11

MANDATORY MEASURES DAYLIGHTING  

E-Print Network [OSTI]

MANDATORY MEASURES DAYLIGHTING Reference: Sub-Chapter 4, Section 130.1(d) #12;SECTION 5 Daylighting daylighting controls. · Lighting in daylit zones should have multi-level steps, per Table 130.1-A · Light levels provided at night should be available at all other times · When sufficient daylight is available

California at Davis, University of

12

DAYLIGHTING DIRECTORY 1/1980  

E-Print Network [OSTI]

shell for passive heating or cooling and daylight. -To consider daylight as having a major contribution inStr. 'NARY PROVIDING A DAYLIGHT ANALYSIS SERVICE USING

,

2012-01-01T23:59:59.000Z

13

Daylight metrics and energy savings  

E-Print Network [OSTI]

lighting energy use under daylight linked lighting controls.simulation of annual daylight illumi- nance distributions –and J. Mardaljevic. Useful daylight illuminances: A replace-

Mardaljevic, John

2011-01-01T23:59:59.000Z

14

MODELING, VERIFICATION AND OPTIMIZATION OF HYBRID GROUND SOURCE HEAT PUMP  

E-Print Network [OSTI]

MODELING, VERIFICATION AND OPTIMIZATION OF HYBRID GROUND SOURCE HEAT PUMP SYSTEMS IN ENERGYPLUS, VERIFICATION AND OPTIMIZATION OF HYBRID GROUND SOURCE HEAT PUMP SYSTEMS IN ENERGYPLUS Thesis Approved by: Dr.................................................................................................................... 16 MODELING OF HYBRID GROUND SOURCE HEAT PUMP SYSTEMS IN ENERGYPLUS

15

What is Daylight: Understanding the Sky as a  

E-Print Network [OSTI]

What is Daylight: Understanding the Sky as a Source May 6, 2007; 2:00 to 5:00 p.m. Michael D and diagrams · Sky Conditions · Daylight Availability · Climate & Design Criteria · Case Studies · Summary · Q the ability of future generations to meet their own needs." · Daylighting strategies should embrace

Ahmad, Sajjad

16

Light and Energy -Daylight measurements  

E-Print Network [OSTI]

Light and Energy - Daylight measurements #12;Light and Energy - Daylight measurements Authors: Jens;3 Title Light and Energy Subtitle Daylight measurements Authors Jens Christoffersen, Ásta Logadóttir ........................................................................................................ 5 Daylight quantity

17

Recovery Act - Geothermal Technologies Program:Ground Source...  

Broader source: Energy.gov (indexed) [DOE]

Recovery Act - Geothermal Technologies Program:Ground Source Heat Pumps Recovery Act - Geothermal Technologies Program:Ground Source Heat Pumps A detailled description of the...

18

Data Analysis from Ground Source Heat Pump Demonstration Projects...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Analysis from Ground Source Heat Pump Demonstration Projects Data Analysis from Ground Source Heat Pump Demonstration Projects Comparison of building energy use before and after...

19

Hybrid Ground Source System Analysis and Tool Development | Department...  

Broader source: Energy.gov (indexed) [DOE]

Hybrid Ground Source System Analysis and Tool Development Hybrid Ground Source System Analysis and Tool Development Project objectives: 1. Compile filtered hourly data for three...

20

Ground Source Heat Pump System Data Analysis  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:Ground Source Heat Pump Subprogram Overview Ground

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office testbed  

E-Print Network [OSTI]

Jonsson JC. 2013. Daylight performance of a microstructuredH. Device for guiding daylight, US Patent 4,654,243 (JL, Selkowitz S. 2000. Daylight in buildings: A source book

Thanachareonkit, Anothai

2014-01-01T23:59:59.000Z

22

MANDATORY MEASURES DAYLIGHTING  

E-Print Network [OSTI]

MANDATORY MEASURES DAYLIGHTING Reference: Sub-Chapter 4, Section 130.1(d) #12;SECTION 4 MINIMUM DAYLIGHTING FOR LARGE SPACES Large enclosed spaces, such as large retail warehouses, are required to have a minimum amount of daylight available when using the prescriptive method of compliance. The minimum

California at Davis, University of

23

PERFORMANCE MODELING OF DAYLIGHT INTEGRATED PHOTOSENSOR- CONTROLLED LIGHTING SYSTEMS  

E-Print Network [OSTI]

Some building energy codes now require the incorporation of daylight into buildings and automatic photosensor-controlled switching or dimming of the electric lighting system in areas that receive daylight. This paper describes enhancements to the open-source Daysim daylight analysis software that permit users to model a photosensor control system as it will perform in a real space, considering the directional sensitivity of the photosensor, its mounting position, the space and daylight aperture geometry, window shading configuration; the electric lighting equipment and control zones; exterior obstructions; and site weather conditions. System output includes assessment of the daylight distribution in a space throughout the year, the photosensor’s ability to properly track the daylight and modify electric lighting system output, and the energy savings provided by the modeled control system. The application of daylight coefficients permits annual simulations to be conducted efficiently using hourly or finer weather data time increments. 1

S. Jain; R. R. Creasey; J. Himmelspach; K. P. White; M. Fu; Richard G. Mistrick

24

Daylight in Guinea-Bissau  

E-Print Network [OSTI]

MYLIGfi Iii GJU£A-BISSAU by HIRAM HALL daylightdaylight of dawning dextrose of my goad the rapidsdreams of~ soul. daylight daylight of my dawning may i wrap

Hall, Hiram

1975-01-01T23:59:59.000Z

25

Overcoming Barriers to Ground Source Heat Pumps in California  

E-Print Network [OSTI]

Overcoming Barriers to Ground Source Heat Pumps in California Geothermal Resources Development Account http://www.energy.ca.gov/geothermal/ grda.html May 2011 The Issue Ground source heat pumps can far made little impact in California. Estimates are that adoption of ground source heat pumps

26

ADVANCES IN MODELING OF GROUND-SOURCE HEAT  

E-Print Network [OSTI]

ADVANCES IN MODELING OF GROUND-SOURCE HEAT PUMP SYSTEMS By ANDREW D. CHIASSON Bachelor of Applied 1999 #12;ii ADVANCES IN MODELING OF GROUND-SOURCE HEAT PUMP SYSTEMS Thesis Approved: Thesis Adviser..............................................................................................................1 1.1. Overview of Ground-Source Heat Pump Systems ..............................................1 1

27

DESIGN OF AN EXPERIMENTAL FACILITY FOR HYBRID GROUND SOURCE HEAT  

E-Print Network [OSTI]

DESIGN OF AN EXPERIMENTAL FACILITY FOR HYBRID GROUND SOURCE HEAT PUMP SYSTEMS By SHAWN ALEX HERN.1 HYBRID GROUND SOURCE HEAT PUMP SYSTEM DESIGN........................................2-3 2.1.1 Design...............................................................................2-5 2.2 HYBRID GROUND SOURCE HEAT PUMP SYSTEM SIMULATION................................2-9 3

28

APPLICATIONS OF HYBRID GROUND SOURCE HEAT PUMP SYSTEMS TO  

E-Print Network [OSTI]

APPLICATIONS OF HYBRID GROUND SOURCE HEAT PUMP SYSTEMS TO BUILDINGS AND BRIDGE DECKS. By MAHADEVAN Chapter Page 1. Introduction 1.1. Overview of hybrid ground source heat pump systems 1.2. Literature review 1.3. Thesis objective and scope 2. Optimal sizing of hybrid ground source heat pump system

29

Energy 101: Daylighting  

ScienceCinema (OSTI)

Daylighting?the use of windows or skylights for natural lighting and temperature regulation?is one building strategy that can save money for homeowners and businesses. Highly efficient, strategically placed windows maximize the use of natural daylight in a building, lowering the need for artificial lighting without causing heating or cooling problems.

None

2013-05-29T23:59:59.000Z

30

Lighting and Daylight Harvesting  

E-Print Network [OSTI]

exposing us to the latest products and technologies. Daylight Harvesting A system of controlling the direction and the quantity of light both natural and artificial within a given space. This implies: Control of fenestration in terms of size..., transmission and direction. Control of reflected light within a space. Control of electric light in terms of delivery and amount Daylight harvesting systems are typically designed to maintain a minimum recommended light level. This light level...

Bos, J.

2011-01-01T23:59:59.000Z

31

Ground-Source Heat Pumps in Cold Climates  

E-Print Network [OSTI]

Ground-Source Heat Pumps in Cold Climates The Current State of the Alaska Industry, a Review-Source Heat Pumps in Cold Climates The Current State of the Alaska Industry, a Review of the Literature and contributions from individuals and organizations involved in ground-source heat pump installation around Alaska

Wagner, Diane

32

Hybrid Ground Source System Analysis and Tool Development  

Broader source: Energy.gov (indexed) [DOE]

Development Principal Investigator Scott Hackel, Energy Center of Wisconsin Ground Source Heat Pumps Demonstration Projects May 18, 2010 This presentation does not contain any...

33

Monitoring SERC Technologies —Geothermal/Ground Source Heat Pumps  

Broader source: Energy.gov [DOE]

A webinar by National Renewable Energy Laboratory Project Leader Dave Peterson about Geothermal/Ground Source Heat Pumps and how to properly monitor its installation.

34

Optimal Ground-Source Heat Pump System Design  

Broader source: Energy.gov (indexed) [DOE]

Ground-Source Heat Pump System Design May 19, 2010 Geothermal Technologies Program 2010 Peer Review ENVIRON International PI : Metin Ozbek Track : GSHP Demonstration Projects This...

35

Abstract A Hierarchical Algorithm for Radiosity Daylighting  

E-Print Network [OSTI]

A new daylight simulation method for radiosity environments is presented. Daylight illumination is transported in a first step where sun and sky are represented as a set of directional sources. Light is transported using parallel projections of these sources. The scene mesh is adaptively subdivided using energy and visibility criteria obtained from a extended scan-line algorithm that computes a layered depth image for each projection. In a second step, diffuse intereflection is computed through a hierarchical Monte Carlo radiosity algorithm. The method is feasible for it extension for environments containing specular surfaces. Relative short time view-independent global illumination results can be obtained with the proposed method, which make it suitable for daylight building design and analysis applications for both indoors and outdoors environments. 1

Gonzalo Besuievsky; Ignacio Martin

36

CALIFORNIA ENERGY Daylighting In Schools  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION Daylighting In Schools: Reanalysis Report TECHNICALREPORT October 2003 Departments, JimVan Dame of My-Lite Daylighting Systems and Products, Doug Gehring of Celotex, Ivan Johnson

37

DAYLIGHTING DIRECTORY 1/1980  

E-Print Network [OSTI]

Lighting Design and ~ylight:ing and Passive Solar Buildin. ~Design and Applications, Febo and Kiarch, 1979. "Daylighting and Passive SolarPassive Solar Conference, pp. 271 - 281, January 1979. TERNOEY, STEVEN "Daylighting Design

,

2012-01-01T23:59:59.000Z

38

Train-the-Trainer As ground source heat  

E-Print Network [OSTI]

Train-the-Trainer As ground source heat pumps capture more of the HVAC market, the need will also receive a copy of the Closed-Loop/ Ground- Source Heat Pump Systems Installation Guide · Soils and Rock Identification · Pump and Fluid Selection Registration information You must be an IGSHPA

39

Ground-source Heat Pumps Applied to Commercial Buildings  

SciTech Connect (OSTI)

Ground-source heat pumps can provide an energy-efficient, cost-effective way to heat and cool commercial facilities. While ground-source heat pumps are well established in the residential sector, their application in larger, commercial-style, facilities is lagging, in part because of a lack of experience with the technology by those in decision-making positions. Through the use of a ground-coupling system, a conventional water-source heat pump design is transformed to a unique means of utilizing thermodynamic properties of earth and groundwater for efficient operation throughout the year in most climates. In essence, the ground (or groundwater) serves as a heat source during winter operation and a heat sink for summer cooling. Many varieties in design are available, so the technology can be adapted to almost any site. Ground-source heat pump systems can be used widely in commercial-building applications and, with proper installation, offer great potential for the commercial sector, where increased efficiency and reduced heating and cooling costs are important. Ground-source heat pump systems require less refrigerant than conventional air-source heat pumps or air-conditioning systems, with the exception of direct-expansion-type ground-source heat pump systems. This chapter provides information and procedures that an energy manager can use to evaluate most ground-source heat pump applications. Ground-source heat pump operation, system types, design variations, energy savings, and other benefits are explained. Guidelines are provided for appropriate application and installation. Two case studies are presented to give the reader a sense of the actual costs and energy savings. A list of manufacturers and references for further reading are included for prospective users who have specific or highly technical questions not fully addressed in this chapter. Sample case spreadsheets are provided in Appendix A. Additional appendixes provide other information on the ground-source heat pump technology.

Parker, Steven A.; Hadley, Donald L.

2009-07-14T23:59:59.000Z

40

Neural daylight control system  

E-Print Network [OSTI]

The paper describes the design, the implementation of a neural controller used in an automatic daylight control system. The automatic lighting control system (ALCS) attempt to maintain constant the illuminance at the desired level on working plane even if the daylight contribution is variable. Therefore, the daylight will represent the perturbation signal for the ALCS. The mathematical model of process is unknown. The applied structure of control need the inverse model of process. For this purpose it was used other artificial neural network (ANN) which identify the inverse model of process in an on-line manner. In fact, this ANN identify the inverse model of process + the perturbation signal. In this way the learning signal for neural controller has a better accuracy for the present application.

Grif, Horatiu Stefan

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

The New York Times headquarters daylighting mockup: Monitored performance of the daylighting control system  

E-Print Network [OSTI]

1999. “Analysis of Daylight Responsive Dimming Systemglare and increase daylight, and 2) Area B had digitalthe stair to approximate the daylight contributions from the

Lee, Eleanor S.; Selkowitz, Stephen E.

2006-01-01T23:59:59.000Z

42

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

quantitative performance indicators of daylight sufficiency?assumptions of existing daylighting performance indicators.existing daylight performance indicators overestimated the

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

43

Combined permeable pavement and ground source heat pump systems   

E-Print Network [OSTI]

The PhD thesis focuses on the performance assessment of permeable pavement systems incorporating ground source heat pumps (GSHP). The relatively high variability of temperature in these systems allows for the survival of pathogenic organisms within...

Grabowiecki, Piotr

2010-01-01T23:59:59.000Z

44

Optimal Design for a Hybrid Ground-Source Heat Pump  

E-Print Network [OSTI]

Although the advantages of ground-source heat pumps over their conventional alternatives make these systems a very attractive choice for air conditioning, not only for residential buildings but increasingly also for institutional and commercial...

Yu, Z.; Yuan, X.; Wang, B.

2006-01-01T23:59:59.000Z

45

Dispersion modeling of ground-level area sources of particulate  

E-Print Network [OSTI]

into the concentration predictions, in order to account for variation or wind speed and direction within an hour period. For ground-level sources, the vertical distribution involves mathematically dispersing the pollutant underground, then reflecting it back up. The next...

Fritz, Bradley Keith

2012-06-07T23:59:59.000Z

46

Ground Source Heat Pump Subprogram Overview | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:Ground Source Heat Pump Subprogram Overview Ground Source

47

Application analysis of ground source heat pumps in building space conditioning  

E-Print Network [OSTI]

for ground-source heat pumps. in ASHRAE Summer Meeting.savings of ground source heat pump systems in Europe: Afor ground-source heat pumps: A literature review,

Qian, Hua

2014-01-01T23:59:59.000Z

48

Daylighting Basics | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Articles Lighting and Daylighting Basics Glossary of Energy-Related Terms Passive Solar Building Design Basics Energy Basics Home Renewable Energy Homes & Buildings Lighting...

49

Daylighting Calculation in DOE-2  

E-Print Network [OSTI]

46 3.2.2 Luminous Efficacy of Solar Radiation . . . . . . .The Availability of Solar Radiation. and Daylight",incidence TSOLNM for solar radiation. TSOLDF =

Winkelmann, F.C

2013-01-01T23:59:59.000Z

50

Advanced fenestration systems for improved daylight performance  

E-Print Network [OSTI]

Systems for Improved Daylight Performance S. Selkowitz, E.S.Systems for Improved Daylight Performance S. Selkowitz, E.S.Introduction The use of daylight to replace or supplement

Selkowitz, S.; Lee, E.S.

1998-01-01T23:59:59.000Z

51

Daylighting | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 NoPublic Utilities Address:011-DNA Jump to:52c8ff988c1 No38e4011f618b No revision hasDawesCounty isDay,Daylighting

52

Marketing Ground Source Heat Pump Advanced Applications that  

E-Print Network [OSTI]

Solar Thermal n Real World Examples Overview #12;n High First Cost n Incompetent Contractor n Operating Wallace President, Energy Environmental Corporation October 9, 2013 #12;Within the United States, what is the fastest growing market with the available capital and need for the benefits of ground source heat pumps

53

Advanced fenestration systems for improved daylight performance  

E-Print Network [OSTI]

daylighting designs is a lack of systems perspective that accounts for, and provides an integrated solution

Selkowitz, S.; Lee, E.S.

1998-01-01T23:59:59.000Z

54

The Lightswitch Wizard -- reliable daylight simulations  

E-Print Network [OSTI]

A web-based, non-expert daylighting analysis tool has been developed to support daylighting-related design decisions in peripheral private offices during an early design stage (http://buildwiz.com). The tool offers a comparative, reliable, and fast analysis of the annual amount of daylight in the offices (daylight factor and daylight autonomy) and the lighting energy performance of automated lighting controls (occupancy sensors, photocells) compared to standard on/off switches. Blinds are either manually or automatically controlled.

For Initial Design; C. F. Morrison; M. Dubrous; C. F. Reinhart ?; M. Morrison; F. Dubrous

55

DAYLIGHTING METRICS: IS THERE A RELATION BETWEEN USEFUL DAYLIGHT ILLUMINANCE AND DAYLIGHT GLARE PROBABILITY?  

E-Print Network [OSTI]

The establishment of climate-based daylight modelling within research and practice has led to a fundamental reassessment of both the basis and purpose of daylight metrics. Whilst there is no consensus yet on the precise nature of the metric(s) that should replace the daylight factor, it is generally agreed that these should be founded on climate-based daylight modelling (CBDM). In this paper we examine the relation between the predicted annual occurrence of glare and one of the candidate CBDM metrics that has been proposed, called useful daylight illuminance (UDI). The purpose is to determine if one or more of the UDI metrics (predicted for the horizontal workplane) could serve as a proxy for the probability of daylight glare (i.e. a measure of vertical illuminance received at the eye). For glare we use the simplified daylight glare probability model. The setting is a residential building which we use as a ‘virtual laboratory ’ in two design configurations, each evaluated under all 32 combinations of 8 European climates and 4 building orientations.

J. Mardaljevic; M. Andersen; N. Roy; J. Christoffersen

56

Integrating automated shading and smart glazings with daylight controls  

E-Print Network [OSTI]

Effect of Venetian Blinds on Daylight Photoelectric Controland Smart Glazings with Daylight Controls Stephen Selkowitzwith the outdoors and daylight to enhance the quality of the

Selkowitz, Stephen; Lee, Eleanor

2004-01-01T23:59:59.000Z

57

Singapore's Zero-Energy Building's daylight monitoring system  

E-Print Network [OSTI]

A and Mardaljevic J, Useful daylight illuminance: a newparadigm for assessing daylight in buildings, LightingJ and Rogers Z, Dynamic daylight performance metrics for

Grobe, Lars

2010-01-01T23:59:59.000Z

58

CALCULATING INTERIOR DAYLIGHT ILLUMINATION WITH A PROGRAMMABLE HAND CALCULATOR  

E-Print Network [OSTI]

Committee E-3.2, "Daylight: International RecommendationsCalculation of Natural Daylight," CIE PUBLICATION No. 16,Committee E-3.2, "Natural Daylight: Official Recommenda-

Bryan, Harvey J.

2013-01-01T23:59:59.000Z

59

CALCULATING INTERIOR DAYLIGHT ILLUMINATION WITH A PROGRAMMABLE HAND CALCULATOR  

E-Print Network [OSTI]

Committee E-3.2, "Daylight: International Recommendationsthe Calculation of Natural Daylight, 11 CIE PUBLICATION No.Committee E-3.2 1 "Natural Daylight: Official Recommenda-

Bryan, Harvey J.

2013-01-01T23:59:59.000Z

60

UNIVERSITY OF CALIFORNIA, SAN DIEGO Acoustic Daylight: passive acoustic imaging  

E-Print Network [OSTI]

UNIVERSITY OF CALIFORNIA, SAN DIEGO Acoustic Daylight: passive acoustic imaging using ambient noise ............................................................................................... xviii SECTION 1: INTRODUCTION Chapter 1: Acoustic Daylight......................................................................... 1 1.2 Acoustic Daylight

Buckingham, Michael

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

A capital cost comparison of commercial ground-source heat pump systems  

SciTech Connect (OSTI)

The report provides a capital cost comparison of commercial ground source heat pump systems. The study includes groundwater systems, ground-coupled systems and hybrid systems.

Rafferty, K.

1994-06-01T23:59:59.000Z

62

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

of Task 21 / Annex 29, Daylight in Buildings. October, 1997.Energy performance of daylight-linked automatic lightingField Commissioning of a daylight-dimming lighting system.

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

63

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

of Task 21 / Annex 29, Daylight in Buildings. October, 1997.Energy performance of daylight-linked automatic lightingBegemann, G. et al. (1997). Daylight, artificial light and

Konis, Kyle Stas

2011-01-01T23:59:59.000Z

64

Ground-source heat pump case studies and utility programs  

SciTech Connect (OSTI)

Ground-source heat pump systems are one of the promising new energy technologies that has shown rapid increase in usage over the past ten years in the United States. These systems offer substantial benefits to consumers and utilities in energy (kWh) and demand (kW) savings. The purpose of this study was to determine what existing monitored data was available mainly from electric utilities on heat pump performance, energy savings and demand reduction for residential, school and commercial building applications. In order to verify the performance, information was collected for 253 case studies from mainly utilities throughout the United States. The case studies were compiled into a database. The database was organized into general information, system information, ground system information, system performance, and additional information. Information was developed on the status of demand-side management of ground-source heat pump programs for about 60 electric utility and rural electric cooperatives on marketing, incentive programs, barriers to market penetration, number units installed in service area, and benefits.

Lienau, P.J.; Boyd, T.L.; Rogers, R.L.

1995-04-01T23:59:59.000Z

65

Daylighting simulation: methods, algorithms, and resources  

SciTech Connect (OSTI)

This document presents work conducted as part of Subtask C, ''Daylighting Design Tools'', Subgroup C2, ''New Daylight Algorithms'', of the IEA SHC Task 21 and the ECBCS Program Annex 29 ''Daylight in Buildings''. The search for and collection of daylighting analysis methods and algorithms led to two important observations. First, there is a wide range of needs for different types of methods to produce a complete analysis tool. These include: Geometry; Light modeling; Characterization of the natural illumination resource; Materials and components properties, representations; and Usability issues (interfaces, interoperability, representation of analysis results, etc). Second, very advantageously, there have been rapid advances in many basic methods in these areas, due to other forces. They are in part driven by: The commercial computer graphics community (commerce, entertainment); The lighting industry; Architectural rendering and visualization for projects; and Academia: Course materials, research. This has led to a very rich set of information resources that have direct applicability to the small daylighting analysis community. Furthermore, much of this information is in fact available online. Because much of the information about methods and algorithms is now online, an innovative reporting strategy was used: the core formats are electronic, and used to produce a printed form only secondarily. The electronic forms include both online WWW pages and a downloadable .PDF file with the same appearance and content. Both electronic forms include live primary and indirect links to actual information sources on the WWW. In most cases, little additional commentary is provided regarding the information links or citations that are provided. This in turn allows the report to be very concise. The links are expected speak for themselves. The report consists of only about 10+ pages, with about 100+ primary links, but with potentially thousands of indirect links. For purposes of the printed version, a list of the links is explicitly provided. This document exists in HTML form at the URL address: http://eande.lbl.gov/Task21/dlalgorithms.html. An equivalent downloadable PDF version, also with live links, at the URL address: http://eande.lbl.gov/Task21/dlalgorithms.pdf. A printed report can be derived directly from either of the electronic versions by simply printing either of them. In addition to the live links in the electronic forms, all report forms, electronic and paper, also have explicitly listed link addresses so that they can be followed up or referenced manually.

Carroll, William L.

1999-12-01T23:59:59.000Z

66

DAYLIGHTING METRICS FOR RESIDENTIAL BUILDINGS  

E-Print Network [OSTI]

It is now widely accepted that the standard method for daylighting evaluation- the daylight factor- is due for replacement with metrics founded on absolute values for luminous quantities predicted over the course of a full year using sun and sky conditions derived from standardised climate files. The move to more realistic measures of daylighting introduces significant levels of additional complexity in both the simulation of the luminous quantities and the reduction of the simulation data to readily intelligible metrics. The simulation component, at least for buildings with standard glazing materials, is reasonably well understood. There is no consensus however on the composition of the metrics, and their formulation is an ongoing area of active research. Additionally, non-domestic and residential buildings present very different evaluation scenarios and it is not yet clear if a single metric would be applicable to both. This study uses a domestic dwelling as the setting to investigate and explore the applicability of daylighting metrics for residential buildings. In addition to daylighting provision for task and disclosing the potential for reducing electric lighting usage, we also investigate the formulation of metrics for non-visual effects such as entrainment of the circadian system.

unknown authors

67

Application analysis of ground source heat pumps in building space conditioning  

E-Print Network [OSTI]

temporal variation of the heat pump COP over the three-monthfor ground-source heat pumps. in ASHRAE Summer Meeting.savings of ground source heat pump systems in Europe: A

Qian, Hua

2014-01-01T23:59:59.000Z

68

Discussion of an Optimization Scheme for the Ground Source Heat Pump System of HVAC  

E-Print Network [OSTI]

With the implementation of the global sustainable development strategy, people pay more attention to renewable energy resources such as ground source heat pumps. The technology of ground source heat pump is widely applied to heat and cold...

Mu, W.; Wang, S.; Pan, S.; Shi, Y.

2006-01-01T23:59:59.000Z

69

4.430 Daylighting, Fall 2006  

E-Print Network [OSTI]

This class provides the tools necessary for an efficient integration of daylighting issues in the overall design of a building. The fundamentals of daylighting and electric lighting are introduced and their relevance to ...

Andersen, Marilyne

70

Daylighting systems for the Kuwait National Museum  

E-Print Network [OSTI]

Daylight has a deteriorating effect on the museum objects. For this reason, usually museums totally block the daylight. This research is the part of restoration works of Kuwait National Museum (KNM), which was destroyed during the Gulf War in 1990...

Ahn, Byoungsoo

2005-08-29T23:59:59.000Z

71

CALIFORNIA ENERGY Summary Of Daylighting In Schools  

E-Print Network [OSTI]

CALIFORNIA ENERGY COMMISSION Summary Of Daylighting In Schools: Reanalysis Report ReanalysisConocha of Federated Departments, Jim Van Dame of My-Lite Daylighting Systems and Products, Doug Gehring of Celotex

72

Fall Back Daylight Savings time is November  

E-Print Network [OSTI]

Fall Back ­ Daylight Savings time is November 2nd.The Energy Policy Act of 2005 changed both the starting and ending dates. Beginning in 2007, daylight time starts on the second Sunday in March and ends

Linsley, Braddock K.

73

Daylighting Prediction Software: Comparative Analysis and Application  

E-Print Network [OSTI]

Daylighting is a beneficial design strategy since it may provide energy savings and contribute to a more sustainable design. In recent studies, daylighting has also been shown to increase staff and student productivity and to decrease absenteeism...

Estes, J. M. Jr.; Schreppler, S.; Newsom, T.

2004-01-01T23:59:59.000Z

74

HYBRID GROUND SOURCE HEAT PUMP SYSTEM SIMULATION USING VISUAL MODELING TOOL FOR HVACSIM+  

E-Print Network [OSTI]

HYBRID GROUND SOURCE HEAT PUMP SYSTEM SIMULATION USING VISUAL MODELING TOOL FOR HVACSIM+ M.H. Khan, 74078, USA ABSTRACT This paper presents a simulation of a hybrid ground source heat pump system, performed using a new graphical user interface for HVACSIM+. Hybrid ground source heat pump systems

75

Daylight metrics and energy savings J. Mardaljevic  

E-Print Network [OSTI]

LBNL-4585E Daylight metrics and energy savings Authors: J. Mardaljevic Institute of Energy 2009; 0: 1­23 ! Daylight metrics and energy savings J. Mardaljevic a , L. Heschong b , E.S. Lee c comfort performance. Current metrics do not account for the temporal and spatial aspects of daylight, nor

76

I Color recognition models of daylight illumi-  

E-Print Network [OSTI]

I Color recognition models of daylight illumi- nation and hybrid reflectance, and predicts of the color of ob- jects with respect to existing models of daylight [12] and surface reflectance [17, 14, 211 a surface reflectance model for hybrid surfaces and a context-based model of daylight illumination

Draper, Bruce A.

77

Daylighting Requirements in the National Building Energy Codes – They’re Here!  

SciTech Connect (OSTI)

Requirements for the control of electric lighting in daylighted areas have historically been avoided in the national building energy codes. This is potentially a rich source of energy savings but as most lighting designers and architects know, daylighting design is not simple! The sheer complication of daylighting design makes crafting daylighting control requirements that could be applied generically in a national energy code a difficult task. However, that is currently changing. The Department of Energy’s (DOE) Building Energy Codes Program (BECP) managed by Pacific Northwest National Laboratory (PNNL) has been supporting the ANSI/ASHRAE/IESNA 90.1 committee in developing improvements to the 90.1 Standard. With subcontract support, the 90.1 Lighting Subcommittee has championed the incorporation of daylighting design and control requirements for the upcoming 2010 version of the nationally available ANSI/ASHRAE/IESNA Standard 90.1 for commercial building energy use.

Richman, Eric E.

2008-06-30T23:59:59.000Z

78

A SIMPLIFIED PROCEDURE FOR CALCULATING THE EFFECTS OF DAYLIGHT FROM CLEAR SKIES  

E-Print Network [OSTI]

J. , "The Calculation of Daylight Factor for Clear Skyand Predetermination of Daylight Illumination," ILLUMINATINGA MEASURING DIAGRAM FOR DAYLIGHT ILLUMINATION, Batsford,

Bryan, Harvey J.

2012-01-01T23:59:59.000Z

79

Development of a Residential Ground-Source Integrated Heat Pump  

SciTech Connect (OSTI)

A residential-size ground-source integrated heat pump (GSIHP) system has been developed and is currently being field tested. The system is a nominal 2-ton (7 kW) cooling capacity, variable-speed unit, which is multi-functional, e.g. space cooling, space heating, dedicated water heating, and simultaneous space cooling and water heating. High-efficiency brushless permanent-magnet (BPM) motors are used for the compressor, indoor blower, and pumps to obtain the highest component performance and system control flexibility. Laboratory test data were used to calibrate a vapor-compression simulation model (HPDM) for each of the four primary modes of operation. The model was used to optimize the internal control options and to simulate the selected internal control strategies, such as controlling to a constant air supply temperature in the space heating mode and a fixed water temperature rise in water heating modes. Equipment performance maps were generated for each operation mode as functions of all independent variables for use in TRNSYS annual energy simulations. These were performed for the GSIHP installed in a well-insulated 2600 ft2(242 m2) house and connected to a vertical ground loop heat exchanger(GLHE). We selected a 13 SEER (3.8 CSPF )/7.7 HSPF (2.3 HSPF, W/W) ASHP unit with 0.90 Energy Factor (EF) resistance water heater as the baseline for energy savings comparisons. The annual energy simulations were conducted over five US climate zones. In addition, appropriate ground loop sizes were determined for each location to meet 10-year minimum and maximum design entering water temperatures (EWTs) to the equipment. The prototype GSIHP system was predicted to use 52 to 59% less energy than the baseline system while meeting total annual space conditioning and water heating loads.

Rice, C Keith [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL; Hern, Shawn [ClimateMaster, Inc.] [ClimateMaster, Inc.; McDowell, Tim [Thermal Energy System Specialists, LLC] [Thermal Energy System Specialists, LLC; Munk, Jeffrey D [ORNL] [ORNL; Shen, Bo [ORNL] [ORNL

2013-01-01T23:59:59.000Z

80

Does Extending Daylight Saving Time Save Energy? Evidence from an Australian Experiment  

E-Print Network [OSTI]

Tellier, F. (2005): Daylight Saving Time and EnergyCEC, 2001: Effects of Daylight Saving Time on California2004): The effects of daylight and daylight saving time on

KELLOGG, RYAN M; Wolff, Hendrik

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Investigating Daylight Quality In Malaysian Government Office Buildings Through Daylight Factor  

E-Print Network [OSTI]

Abstract—In recent years, there has been an increasing interest in using daylight to save energy in buildings. In tropical regions, daylighting is always an energy saver. On the other hand, daylight provides visual comfort. According to standards, it shows that many criteria should be taken into consideration in order to have daylight utilization and visual comfort. The current standard in Malaysia, MS 1525 does not provide sufficient guideline. Hence, more research is needed on daylight performance. If architects do not consider daylight design, it not only causes inconvenience in working spaces but also causes more energy consumption as well as environmental pollution. This research had surveyed daylight performance in 5 selected office buildings from different area of Malaysian through experimental method. Several parameters of daylight quality such as daylight factor, surface luminance and surface luminance ratio were measured in different rooms in each building. The result of this research demonstrated that most of the buildings were not designed for daylight utilization. Therefore, it is very important that architects follow the daylight design recommendation to reduce consumption of electric power for artificial lighting while the sufficient quality of daylight is available. Keywords—Daylight factor, Field measurement, Daylighting quality, Tropical

Surface Luminance; Mohd Zin K; Mohd Sabere Sulaiman; Yong Razidah Rashid; Dilshan Remaz Ossen; Aminatuzuhariah M; Lim Yaik Wah; Mansour Nikpour

82

Feasibility Study of Using Ground Source Heat Pumps in Two Buildings  

E-Print Network [OSTI]

Feasibility Study of Using Ground Source Heat Pumps in Two Buildings at Whidbey Island Naval Air and Mt. Olympus BOQ) presently heated by steam from the central steam plant. Ground source heat pump source heat pumps provide both heating and cooling, there would essentially be no cost increase

Oak Ridge National Laboratory

83

daylight 12/17/2007 1 Tracking the change in the amount of daylight  

E-Print Network [OSTI]

daylight 12/17/2007 1 Tracking the change in the amount of daylight Ever notice that at some times successive days? (c) (Calculus) The daylight graph has been drawn with sine-curve. Find its equation. (d) Use get the following diagram. #12;daylight 12/17/2007 2 0 2 4 6 8 10 12 14 16 18 20 0 20 40 60 80 100 120

Taylor, Peter

84

Effect of daylighting on energy consumption and daylight quality in an existing elementary school  

E-Print Network [OSTI]

EFFECT OF DAYLIGHTING ON ENERGY CONSUMPTION AND DAYLIGHT QUALITY IN AN EXISTING ELEMENTARY SCHOOL A Thesis by UMESH VINAYAK ATRE Submitted to the Office of Graduate Studies of Texas A&M University in partial... fulfillment of the requirements for the degree of MASTER OF SCIENCE May 2005 Major Subject: Architecture EFFECT OF DAYLIGHTING ON ENERGY CONSUMPTION AND DAYLIGHT QUALITY IN AN EXISTING ELEMENTARY SCHOOL A...

Atre, Umesh Vinayak

2005-08-29T23:59:59.000Z

85

Sustainable Energy Resources for Consumers (SERC)- Geothermal/Ground-Source Heat Pumps  

Broader source: Energy.gov [DOE]

Transcript of a presentation, aimed at Sustainable Energy Resources for Consumers (SERC) grantees, provides information on Monitoring Checklists for the installation of Geothermal/Ground-Source Heat Pumps.

86

Sustainable Energy Resources for Consumers (SERC)- Geothermal/Ground-Source Heat Pumps  

Broader source: Energy.gov [DOE]

This presentation, aimed at Sustainable Energy Resources for Consumers (SERC) grantees, provides information on Monitoring Checklists for the installation of Geothermal/Ground-Source Heat Pumps.

87

Implementation and validation of a Ground Source Heat Pump model in MATLAB.  

E-Print Network [OSTI]

??The aim of the project is the implementation of a simple Ground-Source Heat Pump (GSHP) system model in MATLAB. The program is able to run… (more)

Casetta, Damien

2012-01-01T23:59:59.000Z

88

Finite Volume Based Computer Program for Ground Source Heat Pump Systems  

Broader source: Energy.gov [DOE]

Project objective: Create a new modeling decision? tool that will enable ground source heat pump (GSHP) designers and customers to make better design and purchasing decisions.

89

Daylighting controls; Orphan of HVAC design  

SciTech Connect (OSTI)

This paper reports that in the array of strategies employed for energy-efficient design and retrofitting in commercial buildings, the use of daylighting controls is often overlooked or omitted. Thus, daylighting controls are a worthy but neglected orphan of the design process, stranded between the lighting designer, architect and engineer. Most daylighting analysis ignores HVAC effects, despite obvious interactions between windows, heat-from-lights, and thermal loads.

Rundquist, R.A. (R.A. Rundquist Associates Inc., Northampton, MA (US))

1991-11-01T23:59:59.000Z

90

Energy 101: Daylighting | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Highly efficient, strategically placed windows maximize the use of natural daylight in a building, lowering the need for artificial lighting without causing heating or...

91

Do Daylight-Saving Time Adjustments Really Impact Stock Returns?  

E-Print Network [OSTI]

I. Taylor, 1935, World Daylight Saving Time, Chicago: Cur-Sleep at the Market: The Daylight Saving Anomaly”, AmericanSleep at the Market: The Daylight Saving Anomaly: Reply”,

Steigerwald, Douglas G; Conte, Marc

2007-01-01T23:59:59.000Z

92

Simulating the Daylight Performance of Complex Fenestration Systems Using  

E-Print Network [OSTI]

LBNL-4414E Simulating the Daylight Performance of Complex Fenestration Systems Using Bidirectional, January 21, 2011. 1 Simulating the Daylight Performance of Complex Fenestration Systems Using (BSDFs) to model the daylighting performance of complex fenestration systems (CFS), enabling greater

93

Integrated Daylight Harvesting and Occupancy Detection Using Digital Imaging  

E-Print Network [OSTI]

Integrated Daylight Harvesting and Occupancy Detection Using Digital Imaging Abhijit Sarkar dynamic range CMOS video camera to integrate daylight harvesting and occupancy sensing functionalities by these sensors. The prototype involves three algorithms, daylight estimation, occupancy detection and lighting

Salvaggio, Carl

94

BY SHAWN XU, Ph.D. Ground Source Heat Pumps Serve  

E-Print Network [OSTI]

BY SHAWN XU, Ph.D. 1 Ground Source Heat Pumps Serve A Large; BY SHAWN XU, Ph.D. 7 Loop Func>ons § Seasonal storage (Single output) § Hourly buffering (Dual output) #12; BY SHAWN XU, Ph.D. 8 Ground Loops § Ground

95

Ground Source Integrated Heat Pump (GS-IHP) Development  

SciTech Connect (OSTI)

Between October 2008 and May 2013 ORNL and ClimateMaster, Inc. (CM) engaged in a Cooperative Research and Development Agreement (CRADA) to develop a groundsource integrated heat pump (GS-IHP) system for the US residential market. A initial prototype was designed and fabricated, lab-tested, and modeled in TRNSYS (SOLAR Energy Laboratory, et al, 2010) to predict annual performance relative to 1) a baseline suite of equipment meeting minimum efficiency standards in effect in 2006 (combination of air-source heat pump (ASHP) and resistance water heater) and 2) a state-of-the-art (SOA) two-capacity ground-source heat pump with desuperheater water heater (WH) option (GSHPwDS). Predicted total annual energy savings, while providing space conditioning and water heating for a 2600 ft{sup 2} (242 m{sup 2}) house at 5 U.S. locations, ranged from 52 to 59%, averaging 55%, relative to the minimum efficiency suite. Predicted energy use for water heating was reduced 68 to 78% relative to resistance WH. Predicted total annual savings for the GSHPwDS relative to the same baseline averaged 22.6% with water heating energy use reduced by 10 to 30% from desuperheater contributions. The 1st generation (or alpha) prototype design for the GS-IHP was finalized in 2010 and field test samples were fabricated for testing by CM and by ORNL. Two of the alpha units were installed in 3700 ft{sup 2} (345 m{sup 2}) houses at the ZEBRAlliance site in Oak Ridge and field tested during 2011. Based on the steady-state performance demonstrated by the GS-IHPs it was projected that it would achieve >52% energy savings relative to the minimum efficiency suite at this specific site. A number of operational issues with the alpha units were identified indicating design changes needed to the system before market introduction could be accomplished. These were communicated to CM throughout the field test period. Based on the alpha unit test results and the diagnostic information coming from the field test experience, CM developed a 2nd generation (or beta) prototype in 2012. Field test verification units were fabricated and installed at the ZEBRAlliance site in Oak Ridge in May 2012 and at several sites near CM headquarters in Oklahoma. Field testing of the units continued through February 2013. Annual performance analyses of the beta unit (prototype 2) with vertical well ground heat exchangers (GHX) in 5 U.S. locations predict annual energy savings of 57% to 61%, averaging 59% relative to the minimum efficiency suite and 38% to 56%, averaging 46% relative to the SOA GSHPwDS. Based on the steady-state performance demonstrated by the test units it was projected that the 2nd generation units would achieve ~58% energy savings relative to the minimum efficiency suite at the Zebra Alliance site with horizontal GHX. A new product based on the beta unit design was announced by CM in 2012 – the Trilogy 40® Q-mode™ (http://cmdealernet.com/trilogy_40.html). The unit was formally introduced in a March 2012 press release (see Appendix A) and was available for order beginning in December 2012.

Baxter, V. D. [ORNL; Rice, K. [ORNL; Murphy, R. [ORNL; Munk, J. [ORNL; Ally, Moonis [ORNL; Shen, Bo [ORNL; Craddick, William [ORNL; Hearn, Shawn A. [ClimateMaster, Inc.

2013-05-24T23:59:59.000Z

96

International Symposium on Daylighting Buildings (IEA SHC TASK 31) Integrating Automated Shading and Smart Glazings with Daylight  

E-Print Network [OSTI]

International Symposium on Daylighting Buildings (IEA SHC TASK 31) Integrating Automated Shading and Smart Glazings with Daylight Controls Stephen Selkowitz Eleanor Lee Lawrence Berkeley National Laboratory Keywords: daylighting, controls, smart glazing, shading, field testing, IEA31 1. INTRODUCTION Most

97

June 1998Program Description Windows and Daylighting Group  

E-Print Network [OSTI]

June 1998Program Description THERM 2.0 Windows and Daylighting Group Building Technologies, and Dariush Arasteh Windows and Daylighting Group Building Technologies Department Environmental Energy

98

A Practical Analytic Model for Daylight Category: research  

E-Print Network [OSTI]

A Practical Analytic Model for Daylight Category: research Abstract Sunlight and skylight that approximates full spectrum daylight for various atmospheric con­ ditions. These conditions are parameterized

Shirley, Peter

99

A Practical Analytic Model for Daylight Category: research  

E-Print Network [OSTI]

A Practical Analytic Model for Daylight Category: research Abstract Sunlight and skylight that approximates full spectrum daylight for various atmospheric con- ditions. These conditions are parameterized

Shirley, Peter

100

PERFORMANCE ANALYSIS OF A RESIDENTIAL GROUND SOURCE HEAT PUMP SYSTEM WITH ANTIFREEZE SOLUTION  

E-Print Network [OSTI]

PERFORMANCE ANALYSIS OF A RESIDENTIAL GROUND SOURCE HEAT PUMP SYSTEM WITH ANTIFREEZE SOLUTION M in a ground source heat pump system falls near or below 0o C, an antifreeze mixture must be used to prevent freezing in the heat pump. The antifreeze mixture type and concentration has a number of implications

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Efficiency, Economic and Environmental Assessment of Ground-Source Heat Pumps in  

E-Print Network [OSTI]

1 Efficiency, Economic and Environmental Assessment of Ground-Source Heat Pumps in Central pump (GSP) for heating, cooling and hot water in a Central Pennsylvania residence (namely, the author, the efficiency gain for the ground-source heat pump compared to electricity is 43% for cooling and 81

Blumsack, Seth

102

192 ASHRAE Transactions: Research Ground-source heat pumps for cooling-dominated  

E-Print Network [OSTI]

192 ASHRAE Transactions: Research ABSTRACT Ground-source heat pumps for cooling- tion of the heat pump performance is avoided by offsetting the annual load imbalance in the borefield operating and control strategies in a hybrid ground-source heat pump application using an hourly system

Ghajar, Afshin J.

103

Daylight metrics and energy savings  

SciTech Connect (OSTI)

The drive towards sustainable, low-energy buildings has increased the need for simple, yet accurate methods to evaluate whether a daylit building meets minimum standards for energy and human comfort performance. Current metrics do not account for the temporal and spatial aspects of daylight, nor of occupants comfort or interventions. This paper reviews the historical basis of current compliance methods for achieving daylit buildings, proposes a technical basis for development of better metrics, and provides two case study examples to stimulate dialogue on how metrics can be applied in a practical, real-world context.

Mardaljevic, John; Heschong, Lisa; Lee, Eleanor

2009-12-31T23:59:59.000Z

104

Assessing the Feasibility of Creek Daylighting in San Francisco, Part I: A Synthesis of Lessons Learned from Existing Urban Daylighting Projects  

E-Print Network [OSTI]

and Leonardson 2004). Why Daylight? In San Francisco, creekof San Francisco to daylight historical urban creeks withincity governments to daylight urban creeks, with successful

Smith, Brooke Ray

2007-01-01T23:59:59.000Z

105

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

quantitative performance indicators of daylight sufficiency?set of daylighting performance indicators for examination inassumptions of performance indicators under real work

Konis, Kyle Stas

2011-01-01T23:59:59.000Z

106

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

quantitative performance indicators of daylight sufficiency?set of daylighting performance indicators for examination inassumptions of performance indicators under real work

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

107

Hiding patterns with daylight fluorescent inks  

E-Print Network [OSTI]

We propose a method for hiding patterns within printed images by making use of classical and of two daylight fluorescent magenta and yellow inks. Under the D65 illuminant we establish in the CIELAB space the gamut of a classical cmyk printer and the gamut of the same printer using a combination of classical inks with daylight fluorescent inks. These gamuts show that a significant part of the classical ink gamut can be reproduced by combining classical inks with daylight fluorescent inks. By printing parts of images with a combination of classical and daylight fluorescent inks instead of using classical inks only, we can hide security patterns within printed images. Under normal daylight, we do not see any difference between the parts printed with classical inks only and the parts printed with daylight fluorescent inks and classical inks. By changing the illumination, e.g. by viewing the printed image under a tungsten lamp or under a UV lamp, the daylight fluorescent inks change their colors and reveal the security pattern formed by combinations of classical inks and of daylight fluorescent inks.

Romain Rossier; Roger D. Hersch; School Of Computer; Communication Sciences; Ecole Polytechnique; Fédérale Lausanne

108

Study of the design Method of an Efficient Ground Source Heat Pump Thermal Source System in a Cold Area  

E-Print Network [OSTI]

The ground source heat pump (GSHP) system-an energy efficiency and environment friendly system-is becoming popular in many parts of China. However, an imbalance usually exists between the annual heat extracted from and rejected to the ground due...

Shu, H.; Duanmu, L.; Hua, R.; Zou, Y.; Du, G.

2006-01-01T23:59:59.000Z

109

Introduction Ground source heat pump (GSHP) systems are used  

E-Print Network [OSTI]

heating and cooling loads and their distribution over the year, as well as ground thermal properties reduced heating and cooling loads (as compared to conventional construction, USA, spitler@okstate.edu signhilD e.a. gehlin Technical Expert, Swedish Centre for Shallow Geothermal

110

SBi 2006:08 Assessment of daylight quality  

E-Print Network [OSTI]

SBi 2006:08 Assessment of daylight quality in simple rooms Impact of three window configurations on daylight conditions, Phase 2 #12;#12;SBi 2006:08 Danish Building Research Institute 2006 Assessment of daylight quality in simple rooms Impact of three window configurations on daylight conditions, Phase 2

111

EPA (Environmental Protection Agency) activities related to sources of ground-water contamination  

SciTech Connect (OSTI)

The report contains a listing of EPA programs and activities, as of October 1986, that address 33 sources of potential ground-water contamination. The information on each activity is presented in a matrix format that is organized by type of contamination source. The following information is presented for each program and activity listed: title, lead office, contact person, type of activity (study, regulation, guidance, strategy, etc.) status, and a summary of the activity. The 33 sources of ground-water contamination are discussed in the 1984 EPA Office of Technology report: Protecting the Nations Ground Water from Contamination.

Black-Coleman, W.

1987-02-01T23:59:59.000Z

112

Federal Technology Alert: Ground-Source Heat Pumps Applied to Federal Facilities--Second Edition  

SciTech Connect (OSTI)

This Federal Technology Alert, which was sponsored by the U.S. Department of Energy's Office of Federal Energy Management Programs, provides the detailed information and procedures that a Federal energy manager needs to evaluate most ground-source heat pump applications. This report updates an earlier report on ground-source heat pumps that was published in September 1995. In the current report, general benefits of this technology to the Federal sector are described, as are ground-source heat pump operation, system types, design variations, energy savings, and other benefits. In addition, information on current manufacturers, technology users, and references for further reading are provided.

Hadley, Donald L.

2001-03-01T23:59:59.000Z

113

Short communication Optimization of hybrid ground coupled and air source heat pump systems  

E-Print Network [OSTI]

Short communication Optimization of hybrid ­ ground coupled and air source ­ heat pump systems 2008 Accepted 14 January 2010 Available online 28 January 2010 Keywords: Ground coupled heat pump Air to water heat pump Thermal storage device Hybrid HVAC system Energy efficiency Numerical simulation a b

Fernández de Córdoba, Pedro

114

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network [OSTI]

tool for geothermal water loop heat pump systems, 9thInternational IEA Heat Pump Conference, Zürich, Switzerland,Performance of ground source heat pump system in a near-zero

Hong, Tainzhen

2010-01-01T23:59:59.000Z

115

Ground and Water Source Heat Pump Performance and Design for Southern Climates  

E-Print Network [OSTI]

Ground and water source heat pump systems have very attractive performance characteristics when properly designed and installed. These systems typically consist of a water-to-air or water-to-water heat pump linked to a closed loop vertical...

Kavanaugh, S.

1988-01-01T23:59:59.000Z

116

Ground source heat storage and thermo-physical response of soft clay  

E-Print Network [OSTI]

Ground source heat storage can condition buildings with reduced consumption of fossil fuels, an important issue in modem building design. However, seasonal heat storage can cause soil temperature fluctuations and possibly ...

Saxe, Shoshanna Dawn

2009-01-01T23:59:59.000Z

117

ORNL/TM-2008/232 Geothermal (Ground-Source) Heat Pumps  

E-Print Network [OSTI]

ORNL/TM-2008/232 Geothermal (Ground-Source) Heat Pumps: Market Status, Barriers to Adoption Division Sponsored by EERE Geothermal Technologies Program U.S. Department of Energy #12;Page iii DOCUMENT

Oak Ridge National Laboratory

118

ORNL/TM-2008/232 Geothermal (Ground-Source) Heat Pumps  

E-Print Network [OSTI]

ORNL/TM-2008/232 Geothermal (Ground-Source) Heat Pumps: Market Status, Barriers to Adoption Division Sponsored by EERE Geothermal Technologies Program U.S. Department of Energy #12; Page iii

Oak Ridge National Laboratory

119

Ball State University Completes Nation's Largest Ground-Source...  

Energy Savers [EERE]

need an all-of-the-above approach to American energy-an approach that uses homegrown and alternative energy sources designed and produced by American workers," said U.S. Energy...

120

Monitored Energy Performance of Electrochromic Windows Controlled for Daylight and Visual Comfort  

E-Print Network [OSTI]

Windows Controlled for Daylight and Visual Comfort Eleanorof means to bring in daylight while minimizing window glare.was controlled to admit daylight while the lower zone was

Lee, Eleanor S.; DiBartolomeo, Dennis L.; Klems, Joseph; Yazdanian, Mehry; Selkowitz, Stephen E.

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Evaluation of Climate-Based Daylight Performance in Tropical Office Buildings- A Case Study  

E-Print Network [OSTI]

and Z. Rogers, Dynamic Daylight Performance Metrics forof interior design on the daylight availability in open plan2002. [14] Z. Rogers, Daylight metric development using

Szu-Cheng, CHIEN; King Jet, TSENG

2013-01-01T23:59:59.000Z

122

SIMULATION-ASSISTED DAYLIGHT PERFORMANCE ANALYSISIN A HIGH-RISE OFFICE BUILDING IN SINGAPORE  

E-Print Network [OSTI]

Flodberg, K. (2013). “Daylight utilisation in perimeterJ. , (2005a). “Useful Daylight Illuminance: A NewParadigm to Access Daylight in Buildings”. Lighting

CHIEN, Szu Cheng; TSENG, King Jet

2013-01-01T23:59:59.000Z

123

Simulating the Daylight Performance of Complex Fenestration Systems Using Bidirectional Scattering Distribution Functions within Radiance  

E-Print Network [OSTI]

761-81. Tregenza PR. 1983. Daylight coefficients. Lighting773. Reinhart CF. 2001. Daylight availability and manualA visualization of an incident daylight matrix (cumulative

Ward, Gregory

2011-01-01T23:59:59.000Z

124

Does Daylight Saving Time Save Energy? Evidence from a Natural Experiment in Indiana  

E-Print Network [OSTI]

The Energy Impact of Daylight Saving Time Implementation insleep at the market: The daylight saving anomaly. Americansleep at the market: The daylight saving anomaly: Reply.

Kotchen, Matthew J; Grant, Laura E.

2008-01-01T23:59:59.000Z

125

A PROCEDURE FOR CALCULATING INTERIOR DAYLIGHT ILLUMINATION WITH A PROGRAMMABLE HAND CALCULATOR  

E-Print Network [OSTI]

FOR CALCULATING INTERIOR DAYLIGHT ILLUMINATION WITH ACommittee E-3.2, "Daylight: International RecommendationsCalcula- tion of Natural Daylight," CIE PUBLICATION No. 16,

Bryan, H.J.

2010-01-01T23:59:59.000Z

126

Performance of Integrated Systems of Automated Roller Shade Systems and Daylight Responsive Dimming Systems  

E-Print Network [OSTI]

Roller Shade Systems and Daylight Responsive Dimming SystemsRoller Shade Systems and Daylight Responsive Dimming SystemsBerkeley, CA 94720 Abstract Daylight responsive dimming

Park, Byoung-Chul

2011-01-01T23:59:59.000Z

127

Performance-based assessment of daylight on tropical buildings- a case Study  

E-Print Network [OSTI]

81% 81% 95% 96% 74% 68% Daylight autonomy max (DAmax) >5%32% 28% 11% 9% 11% 6% Useful daylight illuminance (UDI) Daylight Performance Metrics for

Szu Cheng, CHIEN

2013-01-01T23:59:59.000Z

128

4.492 Daylighting, Fall 2004  

E-Print Network [OSTI]

The course focuses on the use and optimization of daylight in buildings and on its complementarity to artificial (electric) lighting, to aim at reducing the building's environmental impact while improving the visual comfort ...

Andersen, Marilyne

129

Daylighting Application and Effectiveness in Industrial Facilities  

E-Print Network [OSTI]

during the industrial revolution, architects utilized various daylighting strategies such as window walls, skylighting, monitors, etc. However, glazing technologies were primitive compared with our modern choices, When more efficient and effective...

McCowan, B.; Birleanu, D.

2005-01-01T23:59:59.000Z

130

Development of an integrated building load and ground source heat pump model to assess heat pump and ground loop design and performance in a commercial office building.  

E-Print Network [OSTI]

??Ground source heat pumps (GSHPs) offer an efficient method for cooling and heating buildings, reducing energy usage and operating cost. In hot, arid regions such… (more)

Blair, Jacob Dale

2014-01-01T23:59:59.000Z

131

Utilizing Daylighting Controls in a Manufacturing Facility  

E-Print Network [OSTI]

Utilizing Daylighting Controls in a Manufacturing Facility Som S. Shrestha Dr. Gregory M. Maxwell PhD Candidate Associate Professor som@iastate.edu gmaxwell@iastate.edu Iowa State University Ames, IA ABSTRACT Opportunities exist... to reduce artificial lighting in manufacturing facilities which have skylights and/or fenestration that provide sufficient quantities of daylight to the work space. Using photometric sensors to measure the illuminance in the space, artificial lights can...

Shrestha, S. S.; Maxwell, G. M.

132

Focus group discussions of daylighting practices  

SciTech Connect (OSTI)

This research was sponsored by the US Department of Energy (DOE) Office of Buildings and Community systems and conducted by Pacific Northwest Laboratory (PNL) as part of an ongoing effort to enhance the commercial use of federally developed technologies. One such technology is the use of daylighting practices in the design of nonresidential buildings. This document is a report of the findings from meetings of focus groups conducted to gain insight into building designers' perceptions and attitudes about daylighting systems.

Roberson, B.F.; Harkreader, S.A.

1988-11-01T23:59:59.000Z

133

Singapore's Zero-Energy Building's daylight monitoring system  

E-Print Network [OSTI]

DGP Established performance indicators are illuminanceled to new performance indicators. The Useful Daylightsimulation. The performance indicator used was the Daylight

Grobe, Lars

2010-01-01T23:59:59.000Z

134

Singapore's Zero-Energy Building's daylight monitoring system  

E-Print Network [OSTI]

Daylight Illuminance [12] (UGI) relates the illuminance onin three metrics for the UGI, defining exceeding (>2000lx),

Grobe, Lars

2010-01-01T23:59:59.000Z

135

A Spatially Augmented Reality Sketching Interface for Architectural Daylighting Design  

E-Print Network [OSTI]

1 A Spatially Augmented Reality Sketching Interface for Architectural Daylighting Design Yu Sheng to architectural daylight modeling that allows designers to explore alternative designs and new technologies are then projected on the real model by four calibrated projectors to help users study the daylighting illumination

Varela, Carlos

136

Quantifying the Impact of Daylight Saving Clock Changes  

E-Print Network [OSTI]

Quantifying the Impact of Daylight Saving Clock Changes on Energy Consumption Simon I. Hill of Daylight Saving Clock Changes on Energy Consumption Simon I. Hill, Frédéric Desobry and Yu-Foong Chong May DST Daylight Saving Time EIA Energy Information Administration GDP Gross Domestic Product GMT

Hill, Simon I.

137

15 Acoustic Daylight Imaging in the Michael J. Buckingham  

E-Print Network [OSTI]

15 Acoustic Daylight Imaging in the Ocean Michael J. Buckingham Scripps Institution of Oceanography . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418 15.4 Acoustic daylight images . . . . . . . . . . . . . . . . . . . . . . . . 420 15.5 Concluding. Sensors and Imaging ISBN 0­12­379771­3/$30.00 #12;416 15 Acoustic Daylight Imaging in the Ocean Acoustic

Buckingham, Michael

138

Daylighting a Green High School Smart Schools Symposium 2013  

E-Print Network [OSTI]

Daylighting a Green High School Smart Schools Symposium 2013 #12;AMERICAN CANYON HIGH SCHOOL NAPA CHPS Verified School in CA Daylighting a major focus of sustainable design strategy Began design and orientations First and second story Goals: best daylighting possible flexible lighting system simple and cost

California at Davis, University of

139

Loss of Daylight Vision in Retinal Degeneration: Are  

E-Print Network [OSTI]

Loss of Daylight Vision in Retinal Degeneration: Are Oxidative Stress and Metabolic Dysregulation, particularly in cones, the type of photoreceptors that mediate daylight and color vision. The evidence, providing our daylight vision, and have many of the same features and vulnerabilities as rod photoreceptors

Tabin, Cliff

140

Combining daylighting, personal controls, and load shedding offers  

E-Print Network [OSTI]

Combining daylighting, personal controls, and load shedding offers enormous potential for reducing lighting system to respond to available daylight and demand response control · Allows building occupants--Consider the improved cost-effectiveness of wireless dimming to promote daylighting controls and load- shedding

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Inferring Architectural Designs from Physical Sketches: Application to Daylighting Analysis  

E-Print Network [OSTI]

Inferring Architectural Designs from Physical Sketches: Application to Daylighting Analysis Barbara and a closed, 3D triangle mesh representation is constructed. We apply the system to architectural daylighting, daylighting analy- sis, and image processing. ACM Classification Keywords H.5.1 Information Interfaces

Varela, Carlos

142

The Impact on Energy Consumption of Daylight Saving Clock Changes  

E-Print Network [OSTI]

The Impact on Energy Consumption of Daylight Saving Clock Changes S. I. Hilla, , F. Desobrya , E. W demonstrating po- tential energy savings which could be obtained were Great Britain to maintain Daylight Savings result from an extension of Daylight Saving Time (DST) over the months currently on Greenwich Mean Time

Hill, Simon I.

143

STATE OF CALIFORNIA AUTOMATIC DAYLIGHTING CONTROL ACCEPTANCE DOCUMENT  

E-Print Network [OSTI]

STATE OF CALIFORNIA AUTOMATIC DAYLIGHTING CONTROL ACCEPTANCE DOCUMENT CEC-LTG-3A (Revised 07/10) CALIFORNIA ENERGY COMMISSION CERTIFICATE OF ACCEPTANCE LTG-3A Automatic Daylighting Control Acceptance fraction of rated light output. #12;STATE OF CALIFORNIA AUTOMATIC DAYLIGHTING CONTROL ACCEPTANCE DOCUMENT

144

Singapore's Zero-Energy Building's Daylight Monitoring System  

E-Print Network [OSTI]

LBNL-3708E Singapore's Zero-Energy Building's Daylight Monitoring System Author(s), L. Grobe; S thereof or The Regents of the University of California. #12;Singapore's Zero-Energy Building's daylight, 94720 California, USA 1. Abstract A setup to monitor the daylighting performance of different glazing

145

Designing, selecting and installing a residential ground-source heat pump system  

SciTech Connect (OSTI)

It's a compelling proposition: Use the near-constant-temperature heat underground to heat and cool your home and heat domestic water, slashing your energy bills. Yet despite studies demonstrating significant energy savings from ground-source heat pump (GSHP) systems, their adoption has been hindered by high upfront costs. Fewer than 1% of US homes use a GSHP system. However, compared to a minimum-code-compliant conventional space-conditioning system, when properly designed and installed, a GSHP retrofit at current market prices offers simple payback of 4.3 years on national average, considering existing federal tax credits. Most people understand how air-source heat pumps work: they move heat from indoor air to outdoor air when cooling and from outdoor air to indoor air when heating. The ground-source heat pump operates on the same principle, except that it moves heat to or from the ground source instead of outdoor air. The ground source is usually a vertical or horiontal ground heat exchanger. Because the ground usually has a more favorable temperature than ambient air for the heating and cooling operation of the vapor-compression refrigeration cycle, GSHP sysems can operate with much higher energy efficiencies than air-source heat pump systems when properly designed and installed. A GSHP system used in a residual building typically provides space conditioning and hot water and comprises three major components: a water-source heat pump unit designed to operate at a wider range of entering fluid temperatures (typically from 30 F to 110 F, or 1 C to 43 C) than a conventional water-source heat pump unit; a ground heat exchanger (GHX); and distribution systems to deliver hot water to the storage tank and heating or cooling to the conditioned rooms. In most residual GSHP systems, the circulation pumps and associated valves are integrated with the heat pump to circulate the heat-carrier fluid (water or aqueous antifreeze solution) through the heat pump and the GHX. A recent assessment indicates that if 20% of US homes replaced their existing space-conditioning and water-heating systems with properly designed, installed and operated state-of-the-art GSHP systems, it would yield significant benefits each year. These include 0.8 quad British thermal units (Btu) of primary energy savings, 54.3 million metric tons of CO{sub 2} emission reductions, $10.4 billion in energy cost savings and 43.2 gigawatts of reduction in summer peak electrical demand.

Hughes, Patrick [ORNL; Liu, Xiaobing [ORNL; Munk, Jeffrey D [ORNL

2010-01-01T23:59:59.000Z

146

Ground Source Heat Pump Sub-Slab Heat Exchange Loop Performance in a Cold Climate  

SciTech Connect (OSTI)

This report presents a cold-climate project that examines an alternative approach to ground source heat pump (GSHP) ground loop design. The innovative ground loop design is an attempt to reduce the installed cost of the ground loop heat exchange portion of the system by containing the entire ground loop within the excavated location beneath the basement slab. Prior to the installation and operation of the sub-slab heat exchanger, energy modeling using TRNSYS software and concurrent design efforts were performed to determine the size and orientation of the system. One key parameter in the design is the installation of the GSHP in a low-load home, which considerably reduces the needed capacity of the ground loop heat exchanger. This report analyzes data from two cooling seasons and one heating season. Upon completion of the monitoring phase, measurements revealed that the initial TRNSYS simulated horizontal sub-slab ground loop heat exchanger fluid temperatures and heat transfer rates differed from the measured values. To determine the cause of this discrepancy, an updated model was developed utilizing a new TRNSYS subroutine for simulating sub-slab heat exchangers. Measurements of fluid temperature, soil temperature, and heat transfer were used to validate the updated model.

Mittereder, N.; Poerschke, A.

2013-11-01T23:59:59.000Z

147

Payback Analysis for Ground Source Heat Pump Retrofits Using eQuest Modeling Software  

E-Print Network [OSTI]

There has been much research and analysis done on the performance and potential energy savings related to installing a ground source heat pump (GSHP) system. Much of this research has been dedicated to the new construction industry, and focused on a...

Wahlers, Drake

2011-12-16T23:59:59.000Z

148

A Novel Integrated Frozen Soil Thermal Energy Storage and Ground-Source Heat Pump System  

E-Print Network [OSTI]

In this paper, a novel integrated frozen soil thermal energy storage and ground-source heat pump (IFSTS&GSHP) system in which the GHE can act as both cold thermal energy storage device and heat exchanger for GSHP is first presented. The IFSTS...

Jiang, Y.; Yao, Y.; Rong, L.; Ma, Z.

2006-01-01T23:59:59.000Z

149

A numerical simulation tool for multilayer grounding analysis integrated in an open-source CAD interface  

E-Print Network [OSTI]

of the challenges of the electrical engineers and designers since the beginning of the large-scale harnessing-source platform 1. Introduction Obtaining the distribution of potential levels of an earthing system has been one of electricity. Thus, the grounded electrode dissipates the electrical currents generated during a fault

Colominas, Ignasi

150

COMPUTATIONAL SIMULATIONS FOR PREDICTING VERTICAL DAYLIGHT LEVELS IN ATRIUM BUILDINGS  

E-Print Network [OSTI]

This paper investigates the impact of well geometry and surface reflectance on vertical daylight levels in atria with square forms under a CIE standard overcast sky. By reviewing some previous investigations and comparing with scale model measurements the vertical daylight factor calculated using Radiance are validated. More simulated vertical daylight factors for a very wide range of atrium geometries and reflectances are given. From the results the attenuation and distribution of the vertical daylight levels on the wall of a square atrium with different reflectances are displayed. Also, the comparisons between simulations and two analytical theories have been performed. Finally some conclusions for supporting daylight design in atria are presented.

Jiangtao Du; Steve Sharples

151

Does Daylight Savings Time Affect Traffic Accidents?  

E-Print Network [OSTI]

This paper studies the effect of changes in accident pattern due to Daylight Savings Time (DST). The extension of the DST in 2007 provides a natural experiment to determine whether the number of traffic accidents is affected by shifts in hours...

Deen, Sophia 1988-

2012-04-20T23:59:59.000Z

152

Field Test of High Efficiency Residential Buildings with Ground-source and Air-source Heat Pump Systems  

SciTech Connect (OSTI)

This paper describes the field performance of space conditioning and water heating equipment in four single-family residential structures with advanced thermal envelopes. Each structure features a different, advanced thermal envelope design: structural insulated panel (SIP); optimum value framing (OVF); insulation with embedded phase change materials (PCM) for thermal storage; and exterior insulation finish system (EIFS). Three of the homes feature ground-source heat pumps (GSHPs) for space conditioning and water heating while the fourth has a two-capacity air-source heat pump (ASHP) and a heat pump water heater (HPWH). Two of the GCHP-equipped homes feature horizontal ground heat exchange (GHX) loops that utillize the existing foundation and utility service trenches while the third features a vertical borehole with vertical u-tube GHX. All of the houses were operated under the same simulated occupancy conditions. Operational data on the house HVAC/Water heating (WH) systems are presented and factors influencing overall performance are summarized.

Ally, Moonis Raza [ORNL] [ORNL; Munk, Jeffrey D [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL

2011-01-01T23:59:59.000Z

153

Assessing the Feasibility of Creek Daylighting in San Francisco, Part II: A Preliminary Analysis of Yosemite Creek  

E-Print Network [OSTI]

or purchased properties) to daylight the stream? Or is itrestoration (Smith 2007). Why Daylight in San Francisco? Inof San Francisco to daylight Yosemite Creek, how and where

Smith, Brooke Ray

2007-01-01T23:59:59.000Z

154

Correlation time of ocean ambient noise intensity in San Diego Bay and target recognition in acoustic daylight images  

E-Print Network [OSTI]

Intensity Data Chapter 3 Acoustic Daylight Image TargetC. L. Epifanio. Acoustic Daylight: Passive Acoustic ImagingRecognition in Acoustic Daylight Images A Thesis submitted

Wadsworth, Adam J.

2010-01-01T23:59:59.000Z

155

OpenStudio Enhancements for Whole-Building Daylighting, Airflow...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

aims to boost retrofit projects and enable project teams to easily integrate energy, daylight, and airflow modeling into their design workflows. View the Presentation OpenStudio...

156

Integrating automated shading and smart glazings with daylight controls  

E-Print Network [OSTI]

Automated Shading and Smart Glazings with Daylight Controlsdaylighting, controls, smart glazing, shading, fielddeveloping switchable “smart glazings” for over a decade and

Selkowitz, Stephen; Lee, Eleanor

2004-01-01T23:59:59.000Z

157

Acceleration of the matrix multiplication of Radiance three phase daylighting simulations  

E-Print Network [OSTI]

LBNL-6461E Acceleration of the matrix multiplication of Radiance three phase daylighting multiplication of Radiance three phase daylighting simulations with parallel computing on heterogeneous hardware. Radiance, a lighting simulation program, has been used to conduct daylighting simulations for complex

158

Assessing the Feasibility of Creek Daylighting in San Francisco, Part I: A Synthesis of Lessons Learned from Existing Urban Daylighting Projects  

E-Print Network [OSTI]

daylighting can be cost- comparable with conventional, infrastructure- and material-intensive engineering solutions

Smith, Brooke Ray

2007-01-01T23:59:59.000Z

159

International Workshop on Geomechanics and Energy The Ground as Energy Source and Storage Lausanne, Switzerland, 26-28 November 2013  

E-Print Network [OSTI]

International Workshop on Geomechanics and Energy ­ The Ground as Energy Source and Storage storage. In any such application, a deep understanding of the hydro- mechanical behaviour of the involved region of Switzerland. #12;International Workshop on Geomechanics and Energy ­ The Ground as Energy

Candea, George

160

Tips for Daylighting with Windows  

SciTech Connect (OSTI)

These guidelines provide an integrated approach to the cost-effective design of perimeter zones in new commercial buildings and existing building retrofits. They function as a quick reference for building designers, through a set of easy steps and rules-of-thumb, emphasizing “how-to” practical details. References are given to more detailed sources of information, should the reader wish to go further. The design method used in this document emphasizes that building decisions should be made within the context of the whole building as a single functioning system rather than as an assembly of distinct parts. This integrated design approach looks at the ramifications of each individual system decision on the whole building. For example, the decision on glazing selection will have an effect on lighting, mechanical systems, and interior design. Therefore, the entire design team should participate and influence this glazing decision—which typically rests with the architect alone. The benefit of an integrated design approach is a greater chance of success towards long-term comfort and sustained energy savings in the building.

Robinson, Alastair; Selkowitz, Stephen

2013-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

The New York Times headquarters daylighting mockup: Monitoredperformance of the daylighting control system  

SciTech Connect (OSTI)

A nine-month monitored field study of the performance of automated roller shades and daylighting controls was conducted in a 401 m{sup 2} unoccupied, furnished daylighting mockup. The mockup mimicked the southwest corner of a new 110 km{sub 2} commercial building in New York, New York, where The New York Times will be the major tenant. This paper focuses on evaluating the performance of two daylighting control systems installed in separate areas of an open plan office with 1.2-m high workstation partitions: (1) Area A had 0-10 V dimmable ballasts with an open-loop proportional control system and an automated shade controlled to reduce window glare and increase daylight, and (2) Area B had digital addressable lighting interface (DALI) ballasts with a closed-loop integral reset control system and an automated shade controlled to block direct sun. Daylighting control system performance and lighting energy use were monitored. The daylighting control systems demonstrated very reliable performance after they were commissioned properly. Work plane illuminance levels were maintained above 90% of the maximum fluorescent illuminance level for 99.9{+-}0.5% and 97.9{+-}6.1% of the day on average over the monitored period, respectively, in Areas A and B. Daily lighting energy use savings were significant in both Areas over the equinox-to-equinox period compared to a non-daylit reference case. At 3.35 m from the window, 30% average savings were achieved with a sidelit west-facing condition in Area A while 50-60% were achieved with a bilateral daylit south-facing condition in Area B. At 4.57-9.14 m from the window, 5-10% and 25-40% savings were achieved in Areas A and B, respectively. Average savings for the 7-m deep dimming zone were 20-23% and 52-59% for Areas A and B, respectively, depending on the lighting schedule. The large savings and good reliability can be attributed to the automatic management of the interior shades. The DALI-based system exhibited faulty behavior that remains unexplained, but operational errors are expected to be resolved as DALI products reach full maturity. The building owner received very competitive bids ($30-75 US/DALI ballast) and was able to justify use of the daylighting control system based on operational cost savings and increased amenity. Additional energy savings due to reduced solar and lighting heat gains were not quantified but will add to the total operational cost savings.

Lee, Eleanor S.; Selkowitz, Stephen E.

2006-02-24T23:59:59.000Z

162

Finite Volume Based Computer Program for Ground Source Heat Pump System  

SciTech Connect (OSTI)

This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ?Finite Volume Based Computer Program for Ground Source Heat Pump Systems.? The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The price paid for the three-dimensional detail is the large computational times required with GEO3D. The computational times required for GEO2D are reasonable, a few minutes for a 20 year simulation. For a similar simulation, GEO3D takes days of computational time. Because of the small simulation times with GEO2D, a number of attractive features have been added to it. GEO2D has a user friendly interface where inputs and outputs are all handled with GUI (graphical user interface) screens. These GUI screens make the program exceptionally easy to use. To make the program even easier to use a number of standard input options for the most common GSHP situations are provided to the user. For the expert user, the option still exists to enter their own detailed information. To further help designers and GSHP customers make decisions about a GSHP heating and cooling system, cost estimates are made by the program. These cost estimates include a payback period graph to show the user where their GSHP system pays for itself. These GSHP simulation tools should be a benefit to the advancement of GSHP systems.

Menart, James A. [Wright State University

2013-02-22T23:59:59.000Z

163

Recovery Act: Finite Volume Based Computer Program for Ground Source Heat Pump Systems  

SciTech Connect (OSTI)

This report is a compilation of the work that has been done on the grant DE-EE0002805 entitled ���¢��������Finite Volume Based Computer Program for Ground Source Heat Pump Systems.���¢������� The goal of this project was to develop a detailed computer simulation tool for GSHP (ground source heat pump) heating and cooling systems. Two such tools were developed as part of this DOE (Department of Energy) grant; the first is a two-dimensional computer program called GEO2D and the second is a three-dimensional computer program called GEO3D. Both of these simulation tools provide an extensive array of results to the user. A unique aspect of both these simulation tools is the complete temperature profile information calculated and presented. Complete temperature profiles throughout the ground, casing, tube wall, and fluid are provided as a function of time. The fluid temperatures from and to the heat pump, as a function of time, are also provided. In addition to temperature information, detailed heat rate information at several locations as a function of time is determined. Heat rates between the heat pump and the building indoor environment, between the working fluid and the heat pump, and between the working fluid and the ground are computed. The heat rates between the ground and the working fluid are calculated as a function time and position along the ground loop. The heating and cooling loads of the building being fitted with a GSHP are determined with the computer program developed by DOE called ENERGYPLUS. Lastly COP (coefficient of performance) results as a function of time are provided. Both the two-dimensional and three-dimensional computer programs developed as part of this work are based upon a detailed finite volume solution of the energy equation for the ground and ground loop. Real heat pump characteristics are entered into the program and used to model the heat pump performance. Thus these computer tools simulate the coupled performance of the ground loop and the heat pump. The price paid for the three-dimensional detail is the large computational times required with GEO3D. The computational times required for GEO2D are reasonable, a few minutes for a 20 year simulation. For a similar simulation, GEO3D takes days of computational time. Because of the small simulation times with GEO2D, a number of attractive features have been added to it. GEO2D has a user friendly interface where inputs and outputs are all handled with GUI (graphical user interface) screens. These GUI screens make the program exceptionally easy to use. To make the program even easier to use a number of standard input options for the most common GSHP situations are provided to the user. For the expert user, the option still exists to enter their own detailed information. To further help designers and GSHP customers make decisions about a GSHP heating and cooling system, cost estimates are made by the program. These cost estimates include a payback period graph to show the user where their GSHP system pays for itself. These GSHP simulation tools should be a benefit to the advancement of GSHP system

James A Menart, Professor

2013-02-22T23:59:59.000Z

164

Numerical Simulation of a Latent Heat Storage System of a Solar-Aided Ground Source Heat Pump  

E-Print Network [OSTI]

In this study, the rectangular phase change storage tank (PCST) linked to a solar-aided ground source heat pump (SAGSHP) system is investigated experimentally and theoretically. The container of the phase change material (PCM) is the controlling...

Wang, F.; Zheng, M.; Li, Z.; Lei, B.

2006-01-01T23:59:59.000Z

165

A comparison of ground source heat pumps and micro-combined heat and power as residential greenhouse gas reduction strategies  

E-Print Network [OSTI]

Both ground source heat pumps operating on electricity and micro-combined heat and power systems operating on fossil fuels offer potential for the reduction of green house gas emissions in comparison to the conventional ...

Guyer, Brittany (Brittany Leigh)

2009-01-01T23:59:59.000Z

166

Optimal design of ground source heat pump system integrated with phase change cooling storage tank in an office building  

E-Print Network [OSTI]

Optimal design of ground source heat pump system integrated with phase change cooling storage tank in an office building Na Zhu*, Yu Lei, Pingfang Hu, Linghong Xu, Zhangning Jiang Department of Building Environment and Equipment Engineering... heat pump system integrated with phase change cooling storage technology could save energy and shift peak load. This paper studied the optimal design of a ground source heat pump system integrated with phase change thermal storage tank in an office...

Zhu, N.

2014-01-01T23:59:59.000Z

167

Green Classroom: Daylighting-conscious Design for Kuwait Autism Center  

E-Print Network [OSTI]

Consideration to the natural elements, such as daylighting, at the earliest in the architectural design process is suggested by many as necessary for sustainable buildings. The implementation of a successful daylighting strategy in the design of buildings improves spatial quality and saves energy required, otherwise, for artificial lighting. Daylighting becomes a design mandate in the case of certain spaces; e.g. classrooms in educational buildings. Many researchers have indicated a correlation between the way classrooms are designed and students ' performance. This paper discusses a case study of the environmental design of Kuwait Autism Centre that adopted the provision of adequate daylighting in educational spaces as a major design focus. An extensive daylighting evaluation was conducted on all educational facilities of the proposed conceptual design of the centre. The recommendations from the evaluation were implemented in the design development stages. Earlier conceptual design drawings as well as the final designs are described. The paper summarises the daylighting design recommendations and explains the daylighting simulation process and analysis for decision making in design. Additionally it shows the annual energy savings as a result of the daylighting-conscious design of the classrooms.

Abdullah Al-mohaisen; Omar Khattab

168

The citation for this paper is: Spitler, J.D., X. Liu, S.J. Rees, C. Yavuzturk. 2005. Simulation and Optimization of Ground Source Heat  

E-Print Network [OSTI]

are potentially more efficient than conventional air-to-air systems. In practice, ground-source heat pump systems and Optimization of Ground Source Heat Pump Systems. 8th International Energy Agency Heat Pump Conference. Las Vegas. May 30-June 2. 1 #12;SIMULATION AND OPTIMIZATION OF GROUND SOURCE HEAT PUMP SYSTEMS J.D. Spitler

169

A pre-feasibility study to assess the potential of Open Loop Ground Source Heat to heat and cool the proposed Earth Science Systems Building  

E-Print Network [OSTI]

............................................................1 1.2. History of Ground Source Heat Pump Systems................................................3 1.3. Components of Ground Source Heat Pump Systems..........................................3 1.4. Types of Ground Source Heat Pump Systems ................................................4 1.5. The Earth Systems Science

170

Color and spectral analysis of daylight in southern Europe  

E-Print Network [OSTI]

We have analyzed the colorimetric and spectral characteristics of 2600 daylight spectra (global spectral irradiances on a horizontal surface) measured for all sky states during a 2-year period at Granada, Spain. We describe in detail the chromaticity coordinates, correlated color temperatures (CCT), luminous efficacies, and relative UV and IR contents of Granada daylight. The chromaticity coordinates of Granada daylight lie far above the CIE locus at high CCTs (?9000 K), and a CCT of 5700 K best typifies this daylight. Our principalcomponents analysis shows that Granada daylight spectra can be adequately represented by using sixdimensional linear models in the visible, whereas seven-dimensional models are required if we include the UV or near-IR. Yet on average only three-dimensional models are needed to reconstruct spectra that are colorimetrically indistinguishable from the original spectra. © 2001 Optical Society of America OCIS codes: 010.1290, 330.1710, 330.1730. 1.

Javier Hernández-andrés; Javier Romero; Juan L. Nieves; Raymond L. Lee

2001-01-01T23:59:59.000Z

171

Daylighting, dimming, and the electricity crisis in California  

SciTech Connect (OSTI)

Dimming controls for electric lighting have been one of the mainstays of the effort to use daylighting to reduce annual lighting energy consumption. The coincidence of daylighting with electric utility peak demand makes daylighting controls an effective strategy for reducing commercial building peak electric loads. During times of energy shortage, there is a greatly increased need to reduce electricity use during peak periods, both to ease the burden on electricity providers and to control the operating costs of buildings. The paper presents a typical commercial building electric demand profile during summer, and shows how daylighting-linked lighting controls and load shedding techniques can reduce lighting at precisely those times when electricity is most expensive. We look at the importance of dimming for increasing the reliability of the electricity grid in California and other states, as well as examine the potential cost-effectiveness of widespread use of daylighting to save energy and reduce monthly electricity bills.

Rubinstein, Francis; Neils, Danielle; Colak, Nesrin

2001-09-17T23:59:59.000Z

172

Advanced Ground Source Heat Pump Technology for Very-Low-Energy...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

loop designs being evaluated for their ground loop cost reduction potential
Credit: Oak Ridge National Lab Three newunder-utilized ground loop designs being evaluated for...

173

(Daylight saving time (DST), implemented as an energy saving policy, impacts many other aspects of  

E-Print Network [OSTI]

Abstract( (Daylight saving time (DST), implemented as an energy saving policy, impacts many other(of(DST( The idea of daylight saving time is to transfer an hour of morning daylight to the evening. It is achieved (3am-9am, 9am-3pm, 3pm-9pm, 9pm-12am). The(effects(of(daylight

Levinson, David M.

174

Anomalous trichromats' judgments of surface color in natural scenes under different daylights  

E-Print Network [OSTI]

Anomalous trichromats' judgments of surface color in natural scenes under different daylights daylight illuminants were presented on a high-resolution color monitor to 7 deuteranomalous, 7 to the daylight locus rather than along the daylight locus ~Foster & Linnell, 1995; Amano et al., 2003

Foster, David H.

175

The effects of daylight saving time on vehicle crashes in Minnesota Arthur Huang a,  

E-Print Network [OSTI]

The effects of daylight saving time on vehicle crashes in Minnesota Arthur Huang a, , David: Daylight saving time Vehicle crashes Exposure Traffic volume Introduction: Daylight saving time (DST analysis shows that overall DST reduces crashes. Impact on industry: Daylight saving time can lead to fewer

Levinson, David M.

176

Contamination source review for Building E3236, Edgewood Area, Aberdeen Proving Ground, Maryland  

SciTech Connect (OSTI)

The US Army Aberdeen Proving Ground (APG) commissioned Argonne National Laboratory (ANL) to conduct a contamination source review to identify and define areas of toxic or hazardous contaminants and to assess the physical condition and accessibility of APG buildings. The information obtained from the review may be used to assist the US Army in planning for the future use or disposition of the buildings. The contamination source review consisted of the following tasks: historical records search, physical inspection, photographic documentation, geophysical investigation, and review of available records regarding underground storage tanks associated with each building. This report provides the results of the contamination source review for Building E3236. Many of the APG facilities constructed between 1917 and the 1960s are no longer used because of obsolescence and their poor state of repair. Because many of these buildings were used for research, development, testing, and/or pilot- scale production of chemical warfare agents and other military substances, the potential exists for portions of the buildings to be contaminated with these substances, their degradation products, and other laboratory or industrial chemicals. These buildings and associated structures or appurtenances may contribute to environmental concerns at APG.

Zellmer, S.D.; Smits, M.P.; Draugelis, A.K.; Glennon, M.A.; Rueda, J.; Zimmerman, R.E.

1995-09-01T23:59:59.000Z

177

PARAMETRIC STUDY OF GROUND SOURCE HEAT PUMP SYSTEM FOR HOT AND HUMID CLMATE  

SciTech Connect (OSTI)

The U-tube sizes and varied thermal conductivity with different grout materials are studied based on the benchmark residential building in Hot-humid Pensacola, Florida. In this study, the benchmark building is metered and the data is used to validate the simulation model. And a list of comparative simulation cases with varied parameter value are simulated to study the importance of pipe size and grout to the ground source heat pump energy consumption. The simulation software TRNSYS [1] is employed to fulfill this task. The results show the preliminary energy saving based on varied parameters. Future work needs to be conducted for the cost analysis, include the installation cost from contractor and materials cost.

Jiang Zhu; Yong X. Tao

2011-11-01T23:59:59.000Z

178

Modeling of Standing Column Wells in Ground Source Heat Pump Systems Zheng Deng O'Neill, Ph.D., P.E.  

E-Print Network [OSTI]

Modeling of Standing Column Wells in Ground Source Heat Pump Systems Zheng Deng O'Neill, Ph.D., P Montfort University, Leicester, United Kingdom 1. INTRODUCTION In recent years, ground source heat pump-surface environment: · Ground-coupled heat pump (GCHP) systems (Closed-loop) · Surface water heat pump (SWHP) systems

179

Improving the daylighting conditions of existing buildings : the benefits and limitations of integrating anidolic daylighting systems using the American classroom as a model  

E-Print Network [OSTI]

Awareness of the benefits of good daylighting has risen in recent years, and the designs of many new buildings take daylighting into consideration. However, the majority of our built environment is older than this recent ...

Kleindienst, Siân A. (Siân Alexandra)

2006-01-01T23:59:59.000Z

180

A validation of the Radiance three-phase simulation method for modeling annual daylight performance of optically-complex fenestration systems  

E-Print Network [OSTI]

J. , 2011. Simulating the Daylight Performance of Complexof dynamic RADIANCE-based daylight simulations for a testS.E. , 1998. Energy and Daylight Performance of Angular

McNeil, Andrew

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

An intuitive daylighting performance analysis and optimization approach  

E-Print Network [OSTI]

The effective integration of daylighting considerations into the design process requires many issues to be considered simultaneously, such as daily and seasonal variations, illumination, and thermal comfort. To address the ...

Andersen, Marilyne

182

Daylight variability and contrast-driven architectural effect  

E-Print Network [OSTI]

Natural light is a dynamic and ephemeral tool for expressing the quality of architectural space. As a compliment to more traditional avenues of daylighting research that assess performance in terms of quantitative illuminance ...

Rockcastle, Siobhan Francois

2011-01-01T23:59:59.000Z

183

Automated support for experimental approaches in daylighting performances assessment  

E-Print Network [OSTI]

The study of daylight and solar reflection has been a topic of increasing interest over the past two decades. A novel mechanical support has been constructed to help better understand this topic that consists of a five ...

Ljubicic, Dean M

2006-01-01T23:59:59.000Z

184

DAYLIGHTING IN CAMBRIDGE LIBRARIES: SHIFTING FOCUS OVER TIME  

E-Print Network [OSTI]

This paper aims to explore the various transformations of Cambridge libraries over the ages focusing mainly on the changing role of daylighting in library design. The libraries have been categorised chronologically into four different groups: Medieval libraries, libraries between 16 th cent and Reformation, libraries between Reformation and 19 th cent and modern libraries. The study shows that with the shift from the rules of classicism in medieval libraries to individual styles in modern libraries, the architect has opened up enormous possibilities for design innovations in daylighting. Unlike other environmental services the elements of daylighting are undoubtedly the most visual and expressive. The particular challenge of modern library design is to manipulate natural light for reading and book storage while avoiding reflections on the VDU. It is still a field not fully explored and it remains to be seen how daylighting design can successfully meet all the needs of a modern library. 1.

Ayona Datta

185

Interfacing BIM with Building Thermal and Daylighting Modeling  

E-Print Network [OSTI]

INTERFACING BIM WITH BUILDING THERMAL AND DAYLIGHTING MODELING Wei Yan, Mark Clayton, Jeff Haberl, WoonSeong Jeong, Jong Bum Kim, Sandeep Kota, Jose Luis Bermudez Alcocer, and Manish Dixit Texas A&M University, College Station, USA... the BIM authoring tools’ Application Programming Interface (API) to translate BIM into Object-Oriented Physical Models (in Modelica) for building thermal simulation, and input files of ray-tracing software (Radiance) for daylighting simulation. Based...

Yan, Wei; Clayton, Mark; Haberl, Jeff; WoonSeong, Jeong; Bun Kim, Jong; Sandeep, Kota; Bermudez, Jose; Dixit, Manish

186

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

Annex 29, Daylight in Buildings. October, 1997. Atif. M.R.case studies. Energy and Buildings 35 441-461. Attmann,George. 2010. Sustainable Buildings in Practice: What the

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

187

Ground-Source Integrated Heat Pump for Near-Zero Energy Houses: Technology Status Report  

SciTech Connect (OSTI)

The energy service needs of a net-zero-energy house (ZEH) include space heating and cooling, water heating, ventilation, dehumidification, and humidification, depending on the requirements of the specific location. These requirements differ in significant ways from those of current housing. For instance, the most recent DOE buildings energy data (DOE/BED 2007) indicate that on average {approx}43% of residential buildings primary energy use is for space heating and cooling, vs. {approx}12% for water heating (about a 3.6:1 ratio). In contrast, for the particular prototype ZEH structures used in the analyses in this report, that ratio ranges from about 0.3:1 to 1.6:1 depending on location. The high-performance envelope of a ZEH results in much lower space heating and cooling loads relative to current housing and also makes the house sufficiently air-tight to require mechanical ventilation for indoor air quality. These envelope characteristics mean that the space conditioning load will be closer in size to the water heating load, which depends on occupant behavior and thus is not expected to drop by any significant amount because of an improved envelope. In some locations such as the Gulf Coast area, additional dehumidification will almost certainly be required during the shoulder and cooling seasons. In locales with heavy space heating needs, supplemental humidification may be needed because of health concerns or may be desired for improved occupant comfort. The U.S. Department of Energy (DOE) has determined that achieving their ZEH goal will require energy service equipment that can meet these needs while using 50% less energy than current equipment. One promising approach to meeting this requirement is through an integrated heat pump (IHP) - a single system based on heat pumping technology. The energy benefits of an IHP stem from the ability to utilize otherwise wasted energy; for example, heat rejected by the space cooling operation can be used for water heating. With the greater energy savings the cost of the more energy efficient components required for the IHP can be recovered more quickly than if they were applied to individual pieces of equipment to meet each individual energy service need. An IHP can be designed to use either outdoor air or geothermal resources (e.g., ground, ground water, surface water) as the environmental energy source/sink. Based on a scoping study of a wide variety of possible approaches to meeting the energy service needs for a ZEH, DOE selected the IHP concept as the most promising and has supported research directed toward the development of both air- and ground-source versions. This report describes the ground-source IHP (GS-IHP) design and includes the lessons learned and best practices revealed by the research and development (R&D) effort throughout. Salient features of the GS-IHP include a variable-speed rotary compressor incorporating a brushless direct current permanent magnet motor which provides all refrigerant compression, a variable-speed fan for the indoor section, a multiple-speed ground coil circuit pump, and a single-speed pump for water heating operation. Laboratory IHP testing has thus far used R-22 because of the availability of the needed components that use this refrigerant. It is expected that HFC R-410A will be used for any products arising from the IHP concept. Data for a variable-speed compressor that uses R-410A has been incorporated into the DOE/ORNL Mark VI Heat Pump Design Model (HPDM). HPDM was then linked to TRNSYS, a time-series-dependent simulation model capable of determining the energy use of building cooling and heating equipment as applied to a defined house on a sub-hourly basis. This provided a highly flexible design analysis capability for advanced heat pump equipment; however, the program also took a relatively long time to run. This approach was used with the initial prototype design reported in Murphy et al. (2007a) and in the business case analysis of Baxter (2007).

Murphy, Richard W [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL; Craddick, William G [ORNL

2007-09-01T23:59:59.000Z

188

Application analysis of ground source heat pumps in building space conditioning  

SciTech Connect (OSTI)

The adoption of geothermal energy in space conditioning of buildings through utilizing ground source heat pump (GSHP, also known as geothermal heat pump) has increased rapidly during the past several decades. However, the impacts of the GSHP utilization on the efficiency of heat pumps and soil temperature distribution remained unclear and needs further investigation. This paper presents a novel model to calculate the soil temperature distribution and the coefficient of performance (COP) of GSHP. Different scenarios were simulated to quantify the impact of different factors on the GSHP performance, including heat balance, daily running mode, and spacing between boreholes. Our results show that GSHP is suitable for buildings with balanced cooling and heating loads. It can keep soil temperature at a relatively constant level for more than 10 years. Long boreholes, additional space between boreholes, intermittent running mode will improve the performance of GSHP, but large initial investment is required. The improper design will make the COP of GSHP even lower than traditional heat pumps. Professional design and maintenance technologies are greatly needed in order to promote this promising technology in the developing world.

Qian, Hua; Wang, Yungang

2013-07-01T23:59:59.000Z

189

Geothermal (Ground-Source) Heat Pumps: Market Status, Barriers to Adoption, and Actions to Overcome Barriers  

SciTech Connect (OSTI)

More effective stewardship of our resources contributes to the security, environmental sustainability, and economic well-being of the nation. Buildings present one of the best opportunities to economically reduce energy consumption and limit greenhouse gas emissions. Geothermal heat pump systems (GHPs), sometimes called ground-source heat pump or Geo-Exchange systems, have been proven capable of producing large reductions in energy use and peak demand in buildings. However, GHPs have received little attention at the policy level as an important component of a national energy and climate strategy. Have policymakers mistakenly overlooked GHPs, or are GHPs simply unable to make a major contribution to the national goals for various reasons? This brief study was undertaken at DOE s request to address this conundrum. The scope of the study includes determining the status of global GHP markets and the status of the GHP industry and technology in the United States, assembling previous estimates of GHP energy savings potential and other benefits, identifying key barriers to application of GHPs, and identifying actions that could accelerate market adoption of GHPs. The findings are documented in a report along with conclusions and recommendations. This paper summarizes the key information from the report.

Hughes, Patrick [ORNL

2009-01-01T23:59:59.000Z

190

Contamination source review for Building E3162, Edgewood Area, Aberdeen Proving Ground, Maryland  

SciTech Connect (OSTI)

This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review for Building E3162 at the Aberdeen Proving Ground (APG) in Maryland. The report may be used to assist the US Army in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, and collection of air samples. The field investigations were performed by ANL during 1994 and 1995. Building E3162 (APG designation) is part of the Medical Research Laboratories Building E3160 Complex. This research laboratory complex is located west of Kings Creek, east of the airfield and Ricketts Point Road, and south of Kings Creek Road in the Edgewood Area of APG. The original structures in the E3160 Complex were constructed during World War 2. The complex was originally used as a medical research laboratory. Much of the research involved wound assessment involving chemical warfare agents. Building E3162 was used as a holding and study area for animals involved in non-agent burns. The building was constructed in 1952, placed on inactive status in 1983, and remains unoccupied. Analytical results from these air samples revealed no distinguishable difference in hydrocarbon and chlorinated solvent levels between the two background samples and the sample taken inside Building E3162.

Miller, G.A.; Draugelis, A.K.; Rueda, J.; Zimmerman, R.E.

1995-09-01T23:59:59.000Z

191

Contamination source review for Building E3180, Edgewood Area, Aberdeen Proving Ground, Maryland  

SciTech Connect (OSTI)

This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review of Building E3180 at the Aberdeen Proving Ground (APG) in Maryland. The report may be used to assist the US Army in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, geophysical investigation, collection of air samples, and review of available records regarding underground storage tanks associated with Building E3180. The field investigations were performed by ANL during 1994. Building,E3180 (current APG designation) is located near the eastern end of Kings Creek Road, north of Kings Creek, and about 0.5 miles east of the airstrip within APG`s Edgewood Area. The building was constructed in 1944 as a facsimile of a Japanese pillbox and used for the development of flame weapons systems until 1957 (EAI Corporation 1989). The building was not used from 1957 until 1965, when it was converted and used as a flame and incendiary laboratory. During the 1970s, the building was converted to a machine (metal) shop and used for that purpose until 1988.

Zellmer, S.D.; Smits, M.P.; Rueda, J.; Zimmerman, R.E.

1995-09-01T23:59:59.000Z

192

Contamination source review for Building E3163, Edgewood Area, Aberdeen Proving Ground, Maryland  

SciTech Connect (OSTI)

This report was prepared by Argonne National Laboratory (ANL) to document the results of a contamination source review for Building E3163 at the Aberdeen Proving Ground (APG) in Maryland. This report may be used to assist the US Army in planning for the future use or disposition of this building. The review included a historical records search, physical inspection, photographic documentation, and geophysical investigation. The field investigations were performed by ANL during 1994 and 1995. Building E3163 (APG designation) is part of the Medical Research Laboratories E3160 Complex. This research laboratory complex is located west of Kings Creek, east of the airfield and Ricketts Point Road, and south of Kings Creek Road in the Edgewood Area of APG. The original structures in the E3160 Complex were constructed during World War II. The complex was originally used as a medical research laboratory. Much of the research involved wound assessment. Building E3163, constructed in 1946, was used for toxicological studies on animals until 1965. All agent testing was done using laboratory-scale quantities of agents. All operational data were destroyed; total quantities and types of agents used during the testing are unknown. No experimentation has been conducted in the building since 1965. However, the building was used as overflow office space until the late 1980s. Since that time, the building has been unoccupied.

Draugelis, A.K.; Muir-Ploense, K.L.; Glennon, M.A.; Zimmerman, R.E.

1995-09-01T23:59:59.000Z

193

Geothermal(Ground-Source)Heat Pumps: Market Status, Barriers to Adoption, and Actions to Overcome Barriers  

SciTech Connect (OSTI)

More effective stewardship of our resources contributes to the security, environmental sustainability, and economic well-being of the nation. Buildings present one of the best opportunities to economically reduce energy consumption and limit greenhouse gas emissions. Geothermal heat pumps (GHPs), sometimes called ground-source heat pumps, have been proven capable of producing large reductions in energy use and peak demand in buildings. However, GHPs have received little attention at the policy level as an important component of a national strategy. Have policymakers mistakenly overlooked GHPs, or are GHPs simply unable to make a major contribution to the national goals for various reasons? This brief study was undertaken at DOE's request to address this conundrum. The scope of the study includes determining the status of global GHP markets and the status of the GHP industry and technology in the United States, assembling previous estimates of GHP energy savings potential, identifying key barriers to application of GHPs, and identifying actions that could accelerate market adoption of GHPs. The findings are documented in this report along with conclusions and recommendations.

Hughes, Patrick [ORNL

2008-12-01T23:59:59.000Z

194

Hybrid Ground-Source Heat Pump Installations: Experiences, Improvements, and Tools  

SciTech Connect (OSTI)

One innovation to ground-source heat pump (GSHP, or GHP) systems is the hybrid GSHP (HyGSHP) system, which can dramatically decrease the first cost of GSHP systems by using conventional technology (such as a cooling tower or a boiler) to meet a portion of the peak heating or cooling load. This work uses three case studies (two cooling-dominated, one heating-dominated) to demonstrate the performance of the hybrid approach. Three buildings were studied for a year; the measured data was used to validate models of each system. The models were used to analyze further improvements to the hybrid approach, and establish that this approach has positive impacts, both economically and environmentally. Lessons learned by those who design and operate the systems are also documented, including discussions of equipment sizing, pump operation, and cooling tower control. Finally, the measured data sets and models that were created during this work are described; these materials have been made freely available for further study of hybrid systems.

Scott Hackel; Amanda Pertzborn

2011-06-30T23:59:59.000Z

195

Analysis of Selection of Single or Double U-bend Pipes in a Ground Source Heat Pump System  

E-Print Network [OSTI]

The ground source heat pump (GSHP) system is widely used because of its energy-saving and environmental-friendly characteristics. The buried pipes heat exchangers play an important role in the whole GSHP system design. However, in most cases, single...

Shu, H.; Duanmu, L.; Hua, R.

2006-01-01T23:59:59.000Z

196

In-Depth Look at Ground Source Heat Pumps and Other Electric Loads in Two GreenMax Homes  

SciTech Connect (OSTI)

CARB partnered with WPPI Energy to answer key research questions on in-field performance of ground-source heat pumps and LAMELs through extensive field monitoring at two WPPI GreenMax demonstration homes in Wisconsin. These two test home evaluations provided valuable data on the true in-field performance of various building mechanical systems and lighting, appliances, and miscellaneous loads (LAMELs).

Puttagunta, S.; Shapiro, C.

2012-04-01T23:59:59.000Z

197

Impacts of Soil and Pipe Thermal Conductivity on Performance of Horizontal Pipe in a Ground-source Heat Pump  

E-Print Network [OSTI]

In this paper the composition and thermal property of soil are discussed. The main factors that impact the soil thermal conductivity and several commonly-used pipe materials are studied. A model of heat exchanger with horizontal pipes of ground-source...

Song, Y.; Yao, Y.; Na, W.

2006-01-01T23:59:59.000Z

198

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network [OSTI]

as other types of air source heat pumps, VRF systems needconventional packaged air source heat pumps. Typical GSHPis basically an air source heat pump), especially when the

Hong, Tainzhen

2010-01-01T23:59:59.000Z

199

Exergy and Energy analysis of a ground-source heat pump for domestic water heating under simulated occupancy conditions  

SciTech Connect (OSTI)

This paper presents detailed analysis of a water to water ground source heat pump (WW-GSHP) to provide all the hot water needs in a 345 m2 house located in DOE climate zone 4 (mixed-humid). The protocol for hot water use is based on the Building America Research Benchmark Definition (Hendron 2008; Hendron and Engebrecht 2010) which aims to capture the living habits of the average American household and its impact on energy consumption. The entire house was operated under simulated occupancy conditions. Detailed energy and exergy analysis provides a complete set of information on system efficiency and sources of irreversibility, the main cause of wasted energy. The WW-GSHP was sized at 5.275 kW (1.5-ton) for this house and supplied hot water to a 303 L (80 gal) water storage tank. The WW-GSHP shared the same ground loop with a 7.56 kW (2.1-ton) water to air ground source heat pump (WA-GSHP) which provided space conditioning needs to the entire house. Data, analyses, and measures of performance for the WW-GSHP in this paper complements the results of the WA-GSHP published in this journal (Ally, Munk et al. 2012). Understanding the performance of GSHPs is vital if the ground is to be used as a viable renewable energy resource.

Ally, Moonis Raza [ORNL; Munk, Jeffrey D [ORNL; Baxter, Van D [ORNL; Gehl, Anthony C [ORNL

2012-01-01T23:59:59.000Z

200

Magnetospheric application of high-altitude long-duration balloon technology: Daylight auroral observations  

E-Print Network [OSTI]

Magnetospheric application of high-altitude long-duration balloon technology: Daylight auroral; accepted 12 February 2007 Abstract Daylight auroral imaging is a proposed application of the NASA high

Lummerzheim, Dirk

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Graphical Representation of Climate-Based Daylight Performance to Support Architectural Design  

E-Print Network [OSTI]

Many conventional daylighting design tools are limited in that each simulation represents only one time of year and time of day (or a single, theoretical overcast sky condition). Since daylight is so variable – due to the ...

Kleindienst, Siân

202

Question of the Week: How Do You Feel About the Extended Daylight...  

Broader source: Energy.gov (indexed) [DOE]

Feel About the Extended Daylight Saving Time? Question of the Week: How Do You Feel About the Extended Daylight Saving Time? March 12, 2009 - 6:00am Addthis Have you been drinking...

203

Historical Survey of Daylighting Calculations Methods and Their Use in Energy Performance Simulations  

E-Print Network [OSTI]

This paper traces the historical development of different daylighting calculation methods. Over the years there have been several developments in daylighting calculation methods. The last two decades have seen a number of new ideas and approaches...

Kota, S.; Haberl, J. S.

204

The Soralux Daylighting System : passive solar illumination for deep-plan building spaces  

E-Print Network [OSTI]

Daylight is a valuable resource for both energy and human health. However, this resource is often underutilized in buildings due to the difficulty of controlling the changing qualities of daylight. Deep-plan building spaces ...

Thuot, Kevin W. (Kevin William)

2011-01-01T23:59:59.000Z

205

What is Nonpoint Source Pollution? Nonpoint Source Pollution, or people pollution, is a contamination of our ground water,  

E-Print Network [OSTI]

, recreational water activities, the fishing industry, tourism and our precious drinking water resources, humans and fish. Do not dump used motor oil down storm drains or on the ground. Recycle all used motor such as fertilizing the lawn, walking pets, changing motor oil and littering. With each rainfall, pollutants generated

Rainforth, Emma C.

206

Lighting energy savings potential of split-pane electrochromic windows controlled for daylighting with visual comfort  

E-Print Network [OSTI]

Energy Performance of Electrochromic Windows Controlled forenergy performance of electrochromic windows. Proceedingssignal for daylight (electrochromic window, no overhang).

Fernandes, Luis

2014-01-01T23:59:59.000Z

207

DOES DAYLIGHT SAVING TIME SAVE ENERGY? EVIDENCE FROM A NATURAL EXPERIMENT IN INDIANA  

E-Print Network [OSTI]

DOES DAYLIGHT SAVING TIME SAVE ENERGY? EVIDENCE FROM A NATURAL EXPERIMENT IN INDIANA Matthew J to estimate the effect of daylight saving time (DST) on residential electricity consumption. Our main finding per year. I. Introduction SEVENTY-SIX nations currently practice daylight sav- ing time (DST), which

Kotchen, Matthew J.

208

DELIGHT2 DAYLIGHTING ANALYSIS IN ENERGY PLUS: INTEGRATION AND PRELIMINARY USER RESULTS  

E-Print Network [OSTI]

DELIGHT2 DAYLIGHTING ANALYSIS IN ENERGY PLUS: INTEGRATION AND PRELIMINARY USER RESULTS William L for daylight and electric lighting system analysis in buildings. DElight calculates interior illuminance levels from daylight, and the subsequent contribution required from electric lighting to meet a desired

209

USING VIDEO FOR ANALYZING DAYLIGHT SIMULATION TOOLS Daniel C. Glaser1  

E-Print Network [OSTI]

USING VIDEO FOR ANALYZING DAYLIGHT SIMULATION TOOLS Daniel C. Glaser1 , F. Whitney Smith2 , Barb socio-technical techniques can be employed to analyze video data of people using daylight simulation, a classic daylighting analysis tool; and in the second a lighting professional is asked to use a new data

Varela, Carlos

210

Calculating correlated color temperatures across the entire gamut of daylight and skylight chromaticities  

E-Print Network [OSTI]

Calculating correlated color temperatures across the entire gamut of daylight and skylight daylight and skylight spectra to test an equation that accurately maps CIE 1931 chromaticities x and y by daylight and skylight. © 1999 Optical Society of America OCIS codes: 010.1290, 330.1710, 330.1730. 1

Lee Jr., Raymond L.

211

Development of a new model to predict indoor daylighting : integration in CODYRUN software and validation  

E-Print Network [OSTI]

1 Development of a new model to predict indoor daylighting : integration in CODYRUN software in the scientific literature for determining indoor daylighting values. They are classified in three categories. The originality of our paper relies on the coupling of several simplified models of indoor daylighting

Paris-Sud XI, Université de

212

The following VS tools were compared: 2D OPENBABEL, DAYLIGHT2  

E-Print Network [OSTI]

The following VS tools were compared: 2D ­ OPENBABEL, DAYLIGHT2 , MACCS. BCI, MOLPRINT2D3 3D ­ ROCS Software Inc., Cepos Insilico Ltd., Chemical Computing Group, DAYLIGHT, Chemical Information Systems and Digital Chemistry for providing Academic Licences for ROCS, ParaSurf, MOE, DAYLIGHT, and BCI, respectively

Ritchie, Dave

213

Daylighting control performance of a thin-film ceramic electrochromic window: field study results  

E-Print Network [OSTI]

1 Daylighting control performance of a thin-film ceramic electrochromic window: field study results of this emerging technology. Keywords: Building energy-efficiency; Electrochromic windows; Daylighting; Control switched across their dynamic range and could be fully integrated into a complete daylight, glare

214

AUTOMATING THE SELECTION OF FENESTRATION SYSTEMS TO BEST MEET DAYLIGHTING PERFORMANCE GOALS  

E-Print Network [OSTI]

AUTOMATING THE SELECTION OF FENESTRATION SYSTEMS TO BEST MEET DAYLIGHTING PERFORMANCE GOALS Luís closer to producing the desired flux distribution from the outdoor daylight distribution. INTRODUCTION The selection of fenestration systems for daylighting is traditionally done by trial and error. Designers try

215

P5.60B DERIVATION OF DAYLIGHT AND SOLAR IRRADIANCE DATA FROM SATELLITE OBSERVATIONS  

E-Print Network [OSTI]

P5.60B DERIVATION OF DAYLIGHT AND SOLAR IRRADIANCE DATA FROM SATELLITE OBSERVATIONS A. Hammer, D project SATELLIGHT an attempt is made to use satellite methods to derive daylight and solar irradiance). In daylighting applications, knowledge of the lumi- nance distribution of the sky is of primary concern. Thus

Heinemann, Detlev

216

ACTIVITY OF HAWAIIAN REEF FISHES DURING THE EVENING AND MORNING TRANSITIONS BETWEEN DAYLIGHT AND DARKNESS  

E-Print Network [OSTI]

ACTIVITY OF HAWAIIAN REEF FISHES DURING THE EVENING AND MORNING TRANSITIONS BETWEEN DAYLIGHT inactive at night, the latter mainly inactive in daylight. During active periods their behavior, with the diurnal species mostly inactive in darkness and the nocturnal species mostly inactive in daylight (Hobson

217

Inverse Modeling Using a Wireless Sensor Network (WSN) for Personalized Daylight Harvesting  

E-Print Network [OSTI]

Inverse Modeling Using a Wireless Sensor Network (WSN) for Personalized Daylight Harvesting Ryan: predictive: daylight harvesting: piecewise linear regression: building energy efficiency Abstract: Smart light levels, discretized by sub-hourly sun angles. Applied on two days of daylight and ten days

Agogino, Alice M.

218

SunCast: Fine-grained Prediction of Natural Sunlight Levels for Improved Daylight Harvesting  

E-Print Network [OSTI]

SunCast: Fine-grained Prediction of Natural Sunlight Levels for Improved Daylight Harvesting, USA {jklu,whitehouse}@cs.virginia.edu ABSTRACT Daylight harvesting is the use of natural sunlight to reduce the need for artificial lighting in buildings. The key challenge of daylight harvesting

Whitehouse, Kamin

219

Robustness of circadian clocks to daylight fluctuations: hints from the picoeucaryote  

E-Print Network [OSTI]

1 Robustness of circadian clocks to daylight fluctuations: hints from the picoeucaryote in daylight intensity on the core circadian oscillator, a type of perturbation that has been rarely considered strategy to shield the circadian clock from daylight fluctuations by localizing coupling to the light

Lefranc, Marc

220

Robustness of circadian clocks to daylight fluctuations: hints from the picoeucaryote  

E-Print Network [OSTI]

1 Robustness of circadian clocks to daylight fluctuations: hints from the picoeucaryote a strategy to minimize the impact of fluctuations in daylight intensity on the core circadian oscillator daylight fluctuations by localizing coupling to the light during specific time intervals. In our model

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Using Simple Light Sensors to Achieve Smart Daylight Harvesting Jiakang Lu, Dagnachew Birru, Kamin Whitehouse  

E-Print Network [OSTI]

Using Simple Light Sensors to Achieve Smart Daylight Harvesting Jiakang Lu, Dagnachew Birru, Kamin demonstrate how to improve the effectiveness of daylight harvesting with a sin- gle light sensor on each sky to predict the incoming daylight and set window transparency accordingly. We evaluate our system

Whitehouse, Kamin

222

Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office  

E-Print Network [OSTI]

LBNL-6496E Empirical assessment of a prismatic daylight- redirecting window film in a full in Leukos, the journal of the IESNA. Empirical assessment of a prismatic daylight- redirecting window film Laboratory, Mailstop 90-3111, 1 Cyclotron Road, Berkeley, CA 94720 USA Abstract Daylight redirecting systems

223

Time for a Change? It's not just Daylight Savings Time that should be abolished!  

E-Print Network [OSTI]

1 Time for a Change? It's not just Daylight Savings Time that should be abolished! Sunday, March 11. It is just that the clocks are set differently! By government edict! I advocate not just abolishing Daylight of time zone and/or daylight savings time confusion. Every clock and wristwatch in the world would show

224

Robustness of Circadian Clocks to Daylight Fluctuations: Hints from the Picoeucaryote Ostreococcus tauri  

E-Print Network [OSTI]

Robustness of Circadian Clocks to Daylight Fluctuations: Hints from the Picoeucaryote Ostreococcus in daylight intensity on the core circadian oscillator, a type of perturbation that has been rarely considered F, Bouget F-Y, et al. (2010) Robustness of Circadian Clocks to Daylight Fluctuations: Hints from

Lefranc, Marc

225

Annual daylighting performance of a passive optical light shelf in sidelit perimeter zones of  

E-Print Network [OSTI]

Annual daylighting performance of a passive optical light shelf in sidelit perimeter zones Government or any agency thereof or The Regents of the University of California. #12;1 Annual daylighting use in deep perimeter zones of buildings where the windows are subject to high daylight availability

226

DARKNESS, TWILIGHT, AND DAYLIGHT FORAGING SUCCESS OF BEARS (URSUS AMERICANUS) ON SALMON  

E-Print Network [OSTI]

DARKNESS, TWILIGHT, AND DAYLIGHT FORAGING SUCCESS OF BEARS (URSUS AMERICANUS) ON SALMON IN COASTAL (2000­2002). Bears (maximum 7 simultaneously) were primarily active during daylight near the onset with other bears (4%). Scavenging was greatest during daylight (19%) and lowest during darkness (3%). Bears

Reimchen, Thomas E.

227

Measured Space Conditioning and Water Heating Performance of a Ground-Source Integrated Heat Pump in a Residential Application  

SciTech Connect (OSTI)

In an effort to reduce residential building energy consumption, a ground-source integrated heat pump was developed to meet a home s entire space conditioning and water heating needs, while providing 50% energy savings relative to a baseline suite of minimum efficiency equipment. A prototype 7.0 kW system was installed in a 344 m2 research house with simulated occupancy in Oak Ridge, TN. The equipment was monitored from June 2012 through January 2013.

Munk, Jeffrey D [ORNL] [ORNL; Ally, Moonis Raza [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL; Gehl, Anthony C [ORNL] [ORNL

2014-01-01T23:59:59.000Z

228

Foundation heat exchangers for residential ground source heat pump systems Numerical modeling and experimental validation  

SciTech Connect (OSTI)

A new type of ground heat exchanger that utilizes the excavation often made for basements or foundations has been proposed as an alternative to conventional ground heat exchangers. This article describes a numerical model that can be used to size these foundation heat exchanger (FHX) systems. The numerical model is a two-dimensional finite-volume model that considers a wide variety of factors, such as soil freezing and evapotranspiration. The FHX numerical model is validated with one year of experimental data collected at an experimental house located near Oak Ridge, Tennessee. The model shows good agreement with the experimental data-heat pump entering fluid temperatures typically within 1 C (1.8 F) - with minor discrepancies due to approximations, such as constant moisture content throughout the year, uniform evapotranspiration over the seasons, and lack of ground shading in the model.

Xing, Lu [Oklahoma State University; Cullin, James [Oklahoma State University; Spitler, Jeffery [Oklahoma State University; Im, Piljae [ORNL; Fisher, Daniel [Oklahoma State University

2011-01-01T23:59:59.000Z

229

Analysis of Daylighting Requirements within ASHRAE Standard 90.1  

SciTech Connect (OSTI)

Pacific Northwest National Laboratory (PNNL), under the Building Energy Codes Program (BECP) funded by U.S. Department of Energy (DOE), provides support to the ASHRAE/IES/IESNA Standard 90.1(Standard 90.1) Standing Standards Project Committee (SSPC 90.1) and its subcommittees. In an effort to provide the ASHRAE SSPC 90.1 with data that will improve the daylighting and fenestration requirements in the Standard, PNNL collaborated with Heschong Mahone Group (HMG), now part of TRC Solutions. Combining EnergyPlus, a whole-building energy simulation software developed by DOE, with Radiance, a highly accurate illumination modeling software (Ward 1994), the daylighting requirements within Standard 90.1 were analyzed in greater detail. The initial scope of the study was to evaluate the impact of the fraction of window area compared to exterior wall area (window-to-wall ratio (WWR)) on energy consumption when daylighting controls are implemented. This scope was expanded to study the impact of fenestration visible transmittance (VT), electric lighting controls and daylighted area on building energy consumption.

Athalye, Rahul A.; Xie, YuLong; Liu, Bing; Rosenberg, Michael I.

2013-08-01T23:59:59.000Z

230

Daylight quantum key distribution over 1.6 km  

E-Print Network [OSTI]

Quantum key distribution (QKD) has been demonstrated over a point-to-point $\\sim1.6$-km atmospheric optical path in full daylight. This record transmission distance brings QKD a step closer to surface-to-satellite and other long-distance applications.

W. T. Buttler; R. J. Hughes; S. K. Lamoreaux; G. L. Morgan; J. E. Nordholt; C. G. Peterson

2000-01-25T23:59:59.000Z

231

Technical Feasibility Study for Deployment of Ground-Source Heat Pump Systems: Portsmouth Naval Shipyard -- Kittery, Maine  

SciTech Connect (OSTI)

The U.S. Environmental Protection Agency (EPA) Office of Solid Waste and Emergency Response, in accordance with the RE-Powering America's Lands initiative, engaged the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to conduct feasibility studies to assess the viability of developing renewable energy generating facilities on contaminated sites. Portsmouth Naval Shipyard (PNSY) is a United States Navy facility located on a series of conjoined islands in the Piscataqua River between Kittery, ME and Portsmouth, NH. EPA engaged NREL to conduct a study to determine technical feasibility of deploying ground-source heat pump systems to help PNSY achieve energy reduction goals.

Hillesheim, M.; Mosey, G.

2014-11-01T23:59:59.000Z

232

Integrated Heat Pump (IHP) System Development - Air-Source IHP Control Strategy and Specifications and Ground-Source IHP Conceptual Design  

SciTech Connect (OSTI)

The integrated heat pump (IHP), as one appliance, can provide space cooling, heating, ventilation, and dehumidification while maintaining comfort and meeting domestic water heating needs in near-zero-energy home (NZEH) applications. In FY 2006 Oak Ridge National Laboratory (ORNL) completed development of a control strategy and system specification for an air-source IHP. The conceptual design of a ground-source IHP was also completed. Testing and analysis confirm the potential of both IHP concepts to meet NZEH energy services needs while consuming 50% less energy than a suite of equipment that meets current minimum efficiency requirements. This report is in fulfillment of an FY06 DOE Building Technologies (BT) Joule Milestone.

Murphy, Richard W [ORNL; Rice, C Keith [ORNL; Baxter, Van D [ORNL

2007-05-01T23:59:59.000Z

233

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network [OSTI]

multiple water-to-air heat pump units, which are connectedeach of the water-to-air heat pump units can run in eitheras other types of air source heat pumps, VRF systems need

Hong, Tainzhen

2010-01-01T23:59:59.000Z

234

BIM-Centric Daylight Profiler for Simulation (BDP4SIM): A Methodology for Automated Product Model Decomposition and Recomposition for Climate-Based Daylighting Simulation  

E-Print Network [OSTI]

Flexible problem formulation is required for product model-based thermal analysis using multidisciplinary design optimization (MDO) environments for cost-effectiveness, accuracy, and scalability in the Architecture, Engineering, and Construction (AEC) industry. The integration of daylighting simulation into an MDO process, however, presents several implementation challenges. In current practice, the process of an architect, engineer, or daylighting consultant to determine how to analyze a given building design for daylighting performance is frequently subjective, time-consuming, and inconsistent. Furthermore, long simulation time requirements for daylighting significantly hinder the realization of many benefits from MDO. The determination of which spaces in a building are sufficiently different to warrant an independent daylighting analysis is based primarily on building

Benjamin Welle; Zack Rogers; Martin Fischer; Benjamin Welle A; Zack Rogers B; Martin Fischer

2012-01-01T23:59:59.000Z

235

Building Information Modeling (BIM)-Based Daylighting Simulation and Analysis  

E-Print Network [OSTI]

that the architect and the engineer have to follow to prepare the simulation input files, and the complexity depends on the tools. Currently, Building Information Modeling (BIM) is widely used in the AECO industries and BIM models are used as a means of exchanging... files, graphical user interfaces for defining model geometry were have been created for simulation tools. In addition, geometry modeling tools (CAD tools) were linked with daylighting simulation tools. Currently Building information Model (BIM...

Kota, S.; Haberl, J.S.; Clayton, M.; Yan, W.

236

ANEMOS: A computer code to estimate air concentrations and ground deposition rates for atmospheric nuclides emitted from multiple operating sources  

SciTech Connect (OSTI)

This code estimates concentrations in air and ground deposition rates for Atmospheric Nuclides Emitted from Multiple Operating Sources. ANEMOS is one component of an integrated Computerized Radiological Risk Investigation System (CRRIS) developed for the US Environmental Protection Agency (EPA) for use in performing radiological assessments and in developing radiation standards. The concentrations and deposition rates calculated by ANEMOS are used in subsequent portions of the CRRIS for estimating doses and risks to man. The calculations made in ANEMOS are based on the use of a straight-line Gaussian plume atmospheric dispersion model with both dry and wet deposition parameter options. The code will accommodate a ground-level or elevated point and area source or windblown source. Adjustments may be made during the calculations for surface roughness, building wake effects, terrain height, wind speed at the height of release, the variation in plume rise as a function of downwind distance, and the in-growth and decay of daughter products in the plume as it travels downwind. ANEMOS can also accommodate multiple particle sizes and clearance classes, and it may be used to calculate the dose from a finite plume of gamma-ray-emitting radionuclides passing overhead. The output of this code is presented for 16 sectors of a circular grid. ANEMOS can calculate both the sector-average concentrations and deposition rates at a given set of downwind distances in each sector and the average of these quantities over an area within each sector bounded by two successive downwind distances. ANEMOS is designed to be used primarily for continuous, long-term radionuclide releases. This report describes the models used in the code, their computer implementation, the uncertainty associated with their use, and the use of ANEMOS in conjunction with other codes in the CRRIS. A listing of the code is included in Appendix C.

Miller, C.W.; Sjoreen, A.L.; Begovich, C.L.; Hermann, O.W.

1986-11-01T23:59:59.000Z

237

Validation of the Algorithms Developed for Preliminary Prediction of Daylight Distribution in a Toplighted Atrium  

E-Print Network [OSTI]

VALIDATION OF THE ALGORITHMS DEVELOPED FOR PRELIMINARY PREDICTION OF DAYLIGHT DISTRIBUTION IN A TOPLIGHTED ATRIUM MOHAMED BOUBEKRI MORAD R. ATIF LESTER L. BOYER PhD Candidate PhD Student PhD, Professor Texas A&M University Texas MM University... to understand daylight distribution throughout an atrium space is essential to produce good designs. Simp1 ified daylight prediction algorithms for preliminary design of top1 ighted atriums under overcast and clear diffuse skies have been developed as part...

Boubekri, M.; Atif, M. R.; Boyer, L. L.

1988-01-01T23:59:59.000Z

238

Lighting energy savings potential of split-pane electrochromic windows controlled for daylighting with visual comfort  

E-Print Network [OSTI]

Daylight Coefficients, Lighting Research and Technology,America, 1999, The IESNA lighting handbook: reference andcontrol of electric lighting and blinds, Solar Energy, 77(

Fernandes, Luis

2014-01-01T23:59:59.000Z

239

Intelligent Daylight Panel Control System based on Fuzzy Control for Green Buildings  

E-Print Network [OSTI]

Abstract—This paper proposes an intelligent daylight panel control system based on fuzzy control theory for green buildings. The goal of this research is to automatically modulate sunlight efficiently and to enhance the quality of interior illuminations, thus reducing the need for artificial lighting and conserving energy. Daylight panels are typically installed on the outside of windows. By applying the proposed fuzzy controller, the reflection angle of daylight panels could be adjusted and optimized so that interior illuminative quality is improved and energy-saving is achieved at the same time. Index Terms—daylight panel, intelligent control, fuzzy control. I.

T. C. Kuo; J. S. Lin; Y. Takeuchi; Y. J. Huang

240

Delight2 Daylighting Analysis in Energy Plus: Integration and Preliminary User Results  

E-Print Network [OSTI]

solution to the issue of accounting for solar/thermal influences that will likely change as techniques analogous to the daylighting

Carroll, William L.; Hitchcock, Robert J.

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Daylighting in schools: Improving student performance and health at a price schools can afford: Preprint  

SciTech Connect (OSTI)

Over the next seven years, at least 5,000 new schools will be designed and constructed to meet the needs of American students in kindergarten through grade 12. National efforts are underway to encourage the use of daylighting, energy efficiency, and renewable energy technologies in school designs, which can significantly enhance the learning environment. Recent rigorous statistical studies, involving 21,000 students in three states, reveal that students perform better in daylit classrooms and indicate the health benefits of daylighting. This paper discusses the evidence regarding daylighting and student performance and development, and presents four case studies of schools that have cost effectively implemented daylighting into their buildings.

Plympton, P.; Conway, S.; Epstein, K.

2000-06-14T23:59:59.000Z

242

Applicability of daylighting computer modeling in real case studies: Comparison between measured and simulated daylight availability and lighting consumption. Building and Environment  

E-Print Network [OSTI]

this paper is published in / Une version de ce document se trouve dans : IEA (International Energy Agency) Task 21 / Annex 29: Daylight in Buildings, November 1998, 68 pp. www.nrc.ca/irc/ircpubs NRCC-42862 Subtask C: Daylighting Design Tools T21/C1-21/CAN/98-11 Applicability of Daylighting Computer Modeling in Real Case Studies: Comparison between Measured and Simulated Daylight Availability and Lighting Consumption A report of IEA SHC Task 21 / IEA ECBCS Annex 29 Daylight in Buildings Subtask C: Daylighting Design Tools Report T21/C1-21/CAN/98-11 Applicability of Daylighting Computer Modeling in Real Case Studies: Comparison between Measured and Simulated Daylight Availability and Lighting Consumption by Anca D. Galasiu * Morad R. Atif * A report of IEA SHC Task 21 / IEA ECBCS Annex 29 * National Research Council Canada, Institute for Research in Construction, Indoor Environment Research Program Subtask C: Daylighting Design Tools Report T21/C1-21/CAN/98-11 IEA Solar Heating and Cooling Programme (IEA SHC) The International Energy Agency (IEA) was established in 1974 as an autonomous agency within the framework of the Economic Cooperation and Development (OECD) to carry out a comprehensive program of energy cooperation among its 24 member countries and the Commission of the European Communities. An important part of the Agency's program involves collaboration in the research, development and demonstration of new energy technologies to reduce excessive reliance on imported oil, increase long-term energy security and reduce greenhouse gas emissions. The IEA's R&D activities are headed by the Committee on Energy Research and Technology (CERT) and supported by a small Secretariat staff, headquartered in Paris. In addition, three Working Parties are charged with monitorin...

A. D. Atif

243

A new approach in data visualization to integrate time and space variability of daylighting in the design process  

E-Print Network [OSTI]

Daylighting design has great impact on the performance and aesthetical quality of a work of architecture but requires many issues to be addressed during the design process. The way existing daylighting tools deliver data ...

Yi, Lu, S.M. Massachusetts Institute of Technology

2008-01-01T23:59:59.000Z

244

Study of the relationship between indoor daylight environments and patient average length of stay (ALOS) in healthcare facilities  

E-Print Network [OSTI]

This study investigates how indoor daylight environments affect patient Average Length of Stay (ALOS), by evaluating and analyzing daylight levels in patient rooms in comparison to their ALOS. The patient ALOS data were taken at one general hospital...

Choi, Joon Ho

2007-04-25T23:59:59.000Z

245

Daylight in façade renewal : using new metrics to inform the retrofitting of aging modern-ear façade types  

E-Print Network [OSTI]

New methods for quantifying daylight are increasingly accessible to designers and planners. While these methods have enabled new building facades to better balance the admission of daylight with the maintenance of thermal ...

Rice, Edward Oren

2006-01-01T23:59:59.000Z

246

Overview Models of the Example Space Renderings using the Architectural Daylighting Tool  

E-Print Network [OSTI]

Our new TUI for architectural daylighting design allows multiple users to a) gather around a physical sketching environment and select from b) a set of wall primitives and window and material markers to c) build a rough sketch of an architectural design. A d) visualization of a daylighting simulation is projected onto these surfaces.

Camera B; Joshua Nasman; Barbara Cutler

247

Towards Embedded Wireless-Networked Intelligent Daylighting Systems for Commercial Buildings  

E-Print Network [OSTI]

Towards Embedded Wireless-Networked Intelligent Daylighting Systems for Commercial Buildings Yao, daylighting systems are not widely used in the commercial office building. Barriers prohibiting adoption) `Smart Dust motes' wireless platforms is explored. Due to their small size, they can be placed directly

Agogino, Alice M.

248

Invited paper for the 2001 IESNA National Conference Daylighting, Dimming, and the Electricity Crisis in California  

E-Print Network [OSTI]

, and the Electricity Crisis in California Francis Rubinstein, Danielle Neils and Nesrin Colak Ernest Orlando Lawrence Contract No. DE-AC03-76SF00098. #12;Daylighting, Dimming and California Electricity Crisis Rubinstein, Neils & Colak Daylighting, Dimming, and the Electricity Crisis in California Francis Rubinstein

249

Walking on daylight : the application of translucent floor systems as a means of achieving natural daylighting in mid and low rise architecture  

E-Print Network [OSTI]

This thesis is concerned with the introduction of quality daylight to buildings by means of translucency in the horizontal planes or floors within the building. Since people began to build, the concept of translucency in ...

Widder, James

1985-01-01T23:59:59.000Z

250

Color and spectral analysis of daylight in southern Javier Hernandez-Andres, Javier Romero, and Juan L. Nieves  

E-Print Network [OSTI]

Color and spectral analysis of daylight in southern Europe Javier Herna´ndez-Andre´s, Javier Romero We have analyzed the colorimetric and spectral characteristics of 2600 daylight spectra (global), luminous efficacies, and relative UV and IR contents of Granada daylight. The chromaticity coordinates

Lee Jr., Raymond L.

251

Dynamic daylight control system implementing thin cast arrays of polydimethylsiloxane-based millimeter-scale transparent louvers  

E-Print Network [OSTI]

Dynamic daylight control system implementing thin cast arrays of polydimethylsiloxane: Daylight control system Dynamic window system Energy-efficiency Transparent louvers a b s t r a c in standard office buildings. The development of daylight control systems that maximize the penetration

Aizenberg, Joanna

252

Re: Affordable Textbooks, Fall Semester Update In a message dated 10/28/2010 10:28:50 A.M. Eastern Daylight Time, nicole@studentpirgs.org  

E-Print Network [OSTI]

.M. Eastern Daylight Time, nicole@studentpirgs.org writes: Hi everyone, There have been some exciting

Garfunkel, Eric

253

A CRITICAL REVIEW OF SIMULATION TECHNIQUES FOR DAYLIGHT RESPONSIVE SYSTEMS  

E-Print Network [OSTI]

* corresponding author Application of lighting control technologies has increased the public interest. Although these technologies have been promoted during the last years their successful use in buildings has been accomplished in a small percentage of new projects. One reason is the difficulty in quantifying the energy savings and thus the subsequent payback period. The majority of existing simulation tools (which are embedded in building energy codes) –needed during initial design- are based on the estimation of the potential energy savings due to daylight. The paper focus on the limitations of current simulation approaches comparing their results, in order to assess their accuracy. For this, special test cases have been developed exploiting their domain of validity.

L. Doulos; A. Tsangrassoulis; F. Topalis

254

Building America Case Study: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia (Fact Sheet)  

SciTech Connect (OSTI)

As part of the NAHB Research Center Industry Partnership, Southface partnered with TaC Studios, an Atlanta based architecture firm specializing in residential and light commercial design, on the construction of a new test home in Atlanta, GA in the mixed-humid climate. This home serves as a residence and home office for the firm's owners, as well as a demonstration of their design approach to potential and current clients. Southface believes the home demonstrates current best practices for the mixed-humid climate, including a building envelope featuring advanced air sealing details and low density spray foam insulation, glazing that exceeds ENERGY STAR requirements, and a high performance heating and cooling system. Construction quality and execution was a high priority for TaC Studios and was ensured by a third party review process. Post construction testing showed that the project met stated goals for envelope performance, an air infiltration rate of 2.15 ACH50. The homeowner's wished to further validate whole house energy savings through the project's involvement with Building America and this long-term monitoring effort. As a Building America test home, this home was evaluated to detail whole house energy use, end use loads, and the efficiency and operation of the ground source heat pump and associated systems. Given that the home includes many non-typical end use loads including a home office, pool, landscape water feature, and other luxury features not accounted for in Building America modeling tools, these end uses were separately monitored to determine their impact on overall energy consumption.

Not Available

2014-09-01T23:59:59.000Z

255

Experience of light : the use of an inverse method and a genetic algorithm in daylight design  

E-Print Network [OSTI]

Integration of daylight availability in time and architectural space is a critical element in achieving optimal comfort and productivity, as well as in minimizing energy consumption. In recent years, there has been an ...

Chutarat, Acharawan

2001-01-01T23:59:59.000Z

256

Time-varied daylighting performance to enable a goal-driven design process  

E-Print Network [OSTI]

Due to the overwhelming number of decisions to be made during early stage design, there is a need for intuitive methods to communicate data so that it is quickly and easily understood by the designer. In daylighting analysis, ...

Kleindienst, Siân A. (Siân Alexandra)

2010-01-01T23:59:59.000Z

257

A system for optimizing interior daylight distribution using reflective Venetian blinds with independent blind angle control  

E-Print Network [OSTI]

An operational algorithm for blind angle control is developed to optimize the daylighting performance of a system of reflective Venetian blinds. Numerical modeling and experiment confirm that independent control of alternating ...

McGuire, Molly E

2005-01-01T23:59:59.000Z

258

Form and daylight as a creative medium : Church of John Paul II in South End, Boston  

E-Print Network [OSTI]

This thesis is an architectural design project of a Catholic Church dedicated to Pope John Paul II. The main intention of this Thesis is to explore and clearly present daylighting methods and techniques and how important ...

Gruzewski, Jaroslaw

1992-01-01T23:59:59.000Z

259

Daylighting techniques used in indigenous buildings in the United Arab Emirates (UAE), an investigative approach  

E-Print Network [OSTI]

This study investigated the potential of the daylighting systems used in the indigenous architecture of the United Arab Emirates (UAE), located in Dubai (latitude 25° N longitude 55° E). The analysis tested the lighting performance of three...

Alnuaimi, Maitha Mohammed

2009-06-02T23:59:59.000Z

260

Daylighting Design Tools in Atria for Minimum Cooling Loads in Atrium Buildings  

E-Print Network [OSTI]

The daylighting and sunlighting value of an atrium are considered the main reasons for including the atrium use in the built environment. However, most atria today are either overlit, which causes tremendous cooling loads, or underlit, requiring...

Atif, M. R.; Boyer, L. L.; Degelman, L. O.; Claridge, D. E.

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Daylight Analysis with Microcomputers for School Buildings in a Hot, Humid Climate  

E-Print Network [OSTI]

Daylighting and other passive energy technologies are critical issues that should be considered in the early stages of building planning and architectural design. Both new design and retrofit of existing buildings benefit greatly by use...

Leaver, J.; McQueen, T.

1987-01-01T23:59:59.000Z

262

An Empirical Study and Analysis of Daylight Penetration Through a Light Plenum  

E-Print Network [OSTI]

Lighting accounts for approximately 54% of the annual energy consumption of office buildings, and can effectively be reduced through daylighting. The simplest way to provide day lighting into a typical office space has been to use unilateral...

Hill, G. E.; Rowland, D.; Carlson, K.; Karpack, L.

1985-01-01T23:59:59.000Z

263

Economic and design analysis of daylighting a commercial tower in a hot and humid climate  

E-Print Network [OSTI]

A forty story commercial office tower in Tampa, Florida was redesigned for daylighting. The methods are outlined and results illustrated, A cooling load comparison is done to determine the economic feasibility of such a ...

Roscow, Robert F

1981-01-01T23:59:59.000Z

264

Energy, Shading and Daylighting Analysis for the Austin Bergstrom International Airport Terminal  

E-Print Network [OSTI]

Our firm was under contract with the City of Austin, Texas to perform energy analysis and analysis of the daylighting potential within the New Austin Bergstrom International Airport Terminal. Design of the Passenger Terminal Facility for the New...

Holder, L. M. III; Holder, L. M. IV

2002-01-01T23:59:59.000Z

265

How Do You Use Daylighting While Reducing Excess Heat from Windows...  

Broader source: Energy.gov (indexed) [DOE]

through these windows in the summer. How do you use daylighting while reducing excess heat from windows? Each Thursday, you have the chance to share your thoughts on a question...

266

Energy efficient commercial buildings : a study of natural daylighting in the context of adaptive reuse  

E-Print Network [OSTI]

Daylighting is a powerful design element which can have a dramatic impact on people's perception of space, physical and psychological well-being as well as a building's annual and daily energy requirements. Understanding ...

Crowley, John Stephen

1982-01-01T23:59:59.000Z

267

Cooling Energy and Cost Savings with Daylighting in a Hot and Humid Climate  

E-Print Network [OSTI]

Fenestration performance in nonresidential buildings in hot climates is often a large cooling load liability. Proper fenestration design and the use of daylight-responsive dimming controls on electric lights can, in addition to drastically reducing...

Arasteh, D.; Johnson, R.; Selkowitz, S.; Connell, D.

1985-01-01T23:59:59.000Z

268

Impact of Extended Daylight Saving Time on National Energy Consumption Report to Congress  

SciTech Connect (OSTI)

The Energy Policy Act of 2005 (Pub. L. No. 109-58; EPAct 2005) amended the Uniform Time Act of 1966 (Pub. L. No. 89-387) to increase the portion of the year that is subject to Daylight Saving Time. (15 U.S.C. 260a note) EPAct 2005 extended the duration of Daylight Saving Time in the spring by changing its start date from the first Sunday in April to the second Sunday in March, and in the fall by changing its end date from the last Sunday in October to the first Sunday in November. (15 U.S.C. 260a note) EPAct 2005 also called for the Department of Energy to evaluate the impact of Extended Daylight Saving Time on energy consumption in the United States and to submit a report to Congress. (15 U.S.C. 260a note) This report presents the results of impacts of Extended Daylight Saving Time on the national energy consumption in the United States. The key findings are: (1) The total electricity savings of Extended Daylight Saving Time were about 1.3 Tera Watt-hour (TWh). This corresponds to 0.5 percent per each day of Extended Daylight Saving Time, or 0.03 percent of electricity consumption over the year. In reference, the total 2007 electricity consumption in the United States was 3,900 TWh. (2) In terms of national primary energy consumption, the electricity savings translate to a reduction of 17 Trillion Btu (TBtu) over the spring and fall Extended Daylight Saving Time periods, or roughly 0.02 percent of total U.S. energy consumption during 2007 of 101,000 TBtu. (3) During Extended Daylight Saving Time, electricity savings generally occurred over a three- to five-hour period in the evening with small increases in usage during the early-morning hours. On a daily percentage basis, electricity savings were slightly greater during the March (spring) extension of Extended Daylight Saving Time than the November (fall) extension. On a regional basis, some southern portions of the United States exhibited slightly smaller impacts of Extended Daylight Saving Time on energy savings compared to the northern regions, a result possibly due to a small, offsetting increase in household air conditioning usage. (4) Changes in national traffic volume and motor gasoline consumption for passenger vehicles in 2007 were determined to be statistically insignificant and therefore, could not be attributed to Extended Daylight Saving Time.

Belzer, D. B.; Hadley, S. W.; Chin, S-M.

2008-10-01T23:59:59.000Z

269

An Analysis of Energy Reductions from the Use of Daylighting in Low-Cost Housing  

E-Print Network [OSTI]

AN ANALYSIS OF ENERGY REDUCTIONS FROM THE USE OF DAYLIGHTING IN LOW-COST HOUSING A Thesis by NAYARAT RUNGCHAREONRAT Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements... for the degree of MASTER OF SCIENCE August 2003 Major Subject: Architecture AN ANALYSIS OF ENERGY REDUCTIONS FROM THE USE OF DAYLIGHTING IN LOW-COST HOUSING A Thesis by NAYARAT RUNGCHAREONRAT...

Rungchareonrat, N.

270

CLIMATE-BASED DAYLIGHT PERFORMANCE: BALANCING VISUAL AND NON-VISUAL ASPECTS OF LIGHT INPUT  

E-Print Network [OSTI]

This study uses a domestic dwelling as the setting to investigate and explore the applicability of daylighting metrics for residential buildings, including the formulation of metrics for nonvisual effects. The simulation approach used to generate the performance data from which the metrics are derived is called climate-based daylight modelling (CBDM). This approach delivers predictions of various luminous quantities using sun and sky conditions that are derived from standardised annual meteorological datasets. Although there are uncertainties regarding the precise calibration, there is now sufficient empirical data to parameterise models that also simulate the non-visual aspects of daylight, e.g. for circadian entrainment and a general sense of ?alertness?. For these non-visual aspects, vertical illuminance at the eye was predicted using a modified climate-based daylight modelling approach. In the paper, we consider what relation there might be between the three aspects of daylight provision and if these relations appear to be complementary or conflicting in nature: for task; to reduce electric lighting usage; and, for non-visual effects. The implications for future building guidelines for daylighting are also discussed.

M. Andersen; J. Mardaljevic; Nicolas Roy; Jens Christoffersen

271

Hydrogeologic Evaluation of a Ground-Source Cooling System at the BSF/CSF on the Battelle Campus: Final Report  

SciTech Connect (OSTI)

This report documents both the field characterization activities and the numerical modeling effort at the BSF/CSF site to determine the viability of an open-loop ground source heat pump (GSHP). The primary purpose of the integrated field and modeling study was to determine far-field impacts related to a non-consumptive use water right for the well field containing four extraction and four injection wells. In the field, boreholes were logged and used to develop the geologic conceptual model. Hydraulic testing was performed to identify hydraulic properties and determine sustainable pumping rates. Estimates of the Ringold hydraulic conductivity (60-150 m/d) at the BSF/CSF site were consistent with the local and regional hydrogeology as well as estimates previously published by other investigators. Sustainable pumping rates at the extraction wells were variable (100 – 700 gpm), and confirmed field observations of aquifer heterogeneity. Field data were used to develop a numerical model of the site. Simulations assessed the potential of the well field to impact nearby contaminant plumes, neighboring water rights, and the thermal regime of nearby surface water bodies. Using steady-state flow scenarios in conjunction with particle tracking, a radius of influence of 400–600 m was identified around the well field. This distance was considerably shorter than the distance to the closest contaminant plume (~1.2 km northwest to the DOE Horn Rapids Landfill) and the nearest water right holder (~1.2 km southeast to the City of Richland Well Field). Results demonstrated that current trajectories for nearby contaminant plumes will not be impacted by the operation of the GSHP well field. The objective of the energy transport analysis was to identify potential thermal impacts to the Columbia River under likely operational scenarios for the BSF/CSF well field. Estimated pumping rates and injection temperatures were used to simulate heat transport for a range of hydraulic conductivity estimates for the Ringold Formation. Two different operational scenarios were simulated using conservative assumptions, such as the absence of river water intrusion in the near shore groundwater. When seasonal injection of warm and cool water occurred, temperature impacts were insignificant at the Columbia River (< +0.2ºC), irrespective of the hydraulic conductivity estimate. The second operational scenario simulated continuous heat rejection, a condition anticipated once the BSF/CSF is fully loaded with laboratory and computer equipment. For the continuous heat rejection case, where hourly peak conditions were simulated as month-long peaks, the maximum change in temperature along the shoreline was ~1ºC. If this were to be interpreted as an absolute change in a static river temperature, it could be considered significant. However, the warmer-than-ambient groundwater flux that would potentially discharge to the Columbia River is very small relative to the flow in the river. For temperatures greater than 17.0ºC, the flow relative to a low-flow condition in the river is only 0.012%. Moreover, field data has shown that diurnal fluctuations in temperature are as high as 5ºC along the shoreline.

Freedman, Vicky L.; Mackley, Rob D.; Waichler, Scott R.; Horner, Jacob A.; Moon, Thomas W.; Newcomer, Darrell R.; DeSmet, Darrell J.; Lindsey, K. A.; Porcello, J. J.

2010-05-12T23:59:59.000Z

272

Distinguishing barriers and asperities in near-source ground motion Morgan T. Page, Eric M. Dunham,1  

E-Print Network [OSTI]

process. Numerous kinematic inversions of wave- form data indicate that earthquake ruptures follow complex with equivalent stress drops. This suggests that kinematic models with such constraints overestimate the actual aspects of ground motion in the context of simple but heterogeneous ruptures. [3] Kinematic inversions

Carlson, Jean

273

Measured Performance and Analysis of Ground Source Heat Pumps for Space Conditioning and for Water Heating in a Low-Energy Test House Operated under Simulated Occupancy Conditions  

SciTech Connect (OSTI)

In this paper we present measured performance and efficiency metrics of Ground Source Heat Pumps (GSHPs) for space conditioning and for water heating connected to a horizontal ground heat exchanger (GHX) loop. The units were installed in a 345m2 (3700ft2) high-efficiency test house built with structural insulated panels (SIPs), operated under simulated occupancy conditions, and located in Oak Ridge, Tennessee (USA) in US Climate Zone 4 . The paper describes distinctive features of the building envelope, ground loop, and equipment, and provides detailed monthly performance of the GSHP system. Space conditioning needs of the house were completely satisfied by a nominal 2-ton (7.0 kW) water-to-air GSHP (WA-GSHP) unit with almost no auxiliary heat usage. Recommendations for further improvement through engineering design changes are identified. The comprehensive set of data and analyses demonstrate the feasibility and practicality of GSHPs in residential applications and their potential to help achieve source energy and greenhouse gas emission reduction targets set under the IECC 2012 Standard.

Ally, Moonis Raza [ORNL] [ORNL; Munk, Jeffrey D [ORNL] [ORNL; Baxter, Van D [ORNL] [ORNL; Gehl, Anthony C [ORNL] [ORNL

2012-01-01T23:59:59.000Z

274

Effectiveness of External Window Attachments Based on Daylight Utilization and Cooling Load Reduction for Small Office Buildings in Hot Humid Climates  

E-Print Network [OSTI]

reduce the amount of the daylight needed to supplement interior lighting. Therefore the objective of this study was to explore which strategy would give a balance between solar heat gain reduction and daylight utilization and result in the most energy...

Soebarto, V. I.; Degelman, L. O.

1994-01-01T23:59:59.000Z

275

CITI Program Website Downtime for Software Upgrade Starting Monday 29 July at 11 a.m. U.S. Eastern Daylight Time, the CITI Program website will be  

E-Print Network [OSTI]

.S. Eastern Daylight Time, the CITI Program website will be unavailable for approximately two to three days

276

BUILDING RESEARCH & INFORMATION (2008) Paper in press (mock proof) expected to appear in Vol 36 No 6 (Nov 2008) An intuitive daylighting performance  

E-Print Network [OSTI]

No 6 (Nov 2008) An intuitive daylighting performance analysis and optimization approach M. Andersen1 of daylighting considerations into the design process requires many issues to be addressed simultaneously quantitative and qualitative performance criteria using daylighting analysis data in various forms

Varela, Carlos

277

CLTC is a not-for-profit research, development and demonstration facility leading innovations in energy-efficient lighting and daylighting technologies.  

E-Print Network [OSTI]

in energy-efficient lighting and daylighting technologies. Collaborating with partners in government common ways CLTC utilizes funding to advance the science of energy-efficient lighting and daylighting and field test emerging lighting and daylighting technologies. Demonstrations help vet the performance

California at Davis, University of

278

Evaluation of the Daylight Cycle of Model-Predicted Cloud Amount and Condensed Water Path over Europe with Observations from MSG SEVIRI  

E-Print Network [OSTI]

Evaluation of the Daylight Cycle of Model-Predicted Cloud Amount and Condensed Water Path over accurate information on diurnal cycles during daylight hours of cloud properties over land and ocean surfaces. This paper evaluates the daylight cycle of CA and CWP as predicted by the Regional Atmospheric

Stoffelen, Ad

279

Impact of Fixed Exterior Shading on Daylighting: A Case Study of the David Brower Center  

E-Print Network [OSTI]

blind systems were always lowered and seasonally adjusted (continued on next page) MS Thesis,Thesis, Dept. of Architecture, UC Berkeley 2011 http://escholarship.org/uc/item/1mq5k9mw blinds,blinds frequently enough to take advantage of daylighting. 14 While MS Thesis,

Zelenay, Krystyna

2011-01-01T23:59:59.000Z

280

D i i f S t i bilit i th B ilt E i tDesigning for Sustainability in the Built Environment Exterior Facade Design for Maximum Daylighting and Solar Power  

E-Print Network [OSTI]

Facade Design for Maximum Daylighting and Solar Power GenerationGeneration A frank assessment of issues "...the art and science of daylighting is not so much about how to provide enough daylighting as how to do LIGHTING CHARACTER DUE TO DAYLIGHT VARIABILITY · PSYCHOLOGICAL BENEFITS OF· PSYCHOLOGICAL BENEFITS

Massachusetts at Amherst, University of

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Exergy Analysis and Operational Efficiency of a Horizontal Ground Source Heat Pump System Operated in a Low-Energy Test House under Simulated Occupancy Conditions  

SciTech Connect (OSTI)

This paper presents data, analyses, measures of performance, and conclusions for a ground-source heat pump (GSHP) providing space conditioning to a 345m2 house whose envelope is made of structural insulated panels (SIP). The entire thermal load of this SIP house with RSI-3.7 (RUS-21) walls, triple pane windows with a U-factor of 1.64 W/m2 K (0.29 Btu/h ft2 oF) and solar heat gain coefficient (SHGC) of 0.25, a roof assembly with overall thermal resistance of about RSI-8.8 (RUS-50) and low leakage rates of 0.74 ACH at 50Pa was satisfied with a 2.16-Ton (7.56 kW) GSHP unit consuming negligible (9.83kWh) auxiliary heat during peak winter season. The highest and lowest heating COP achieved was 4.90 (October) and 3.44 (February), respectively. The highest and lowest cooling COP achieved was 6.09 (April) and 3.88 (August). These COPs are calculated on the basis of the total power input (including duct, ground loop, and control power losses ). The second Law (Exergy) analysis provides deep insight into how systemic inefficiencies are distributed among the various GSHP components. Opportunities for design and further performance improvements are identified. Through Exergy analysis we provide a true measure of how closely actual performance approaches the ideal, and it unequivocally identifies, better than energy analysis does, the sources and causes of lost work, the root cause of system inefficiencies.

Ally, Moonis Raza [ORNL; Baxter, Van D [ORNL; Munk, Jeffrey D [ORNL; Gehl, Anthony C [ORNL

2012-01-01T23:59:59.000Z

282

Pre-Shot Simulations of Far-Field Ground Motions for the Source Physics Experiment (SPE) Explosions at the Climax Stock, Nevada National Security Site  

SciTech Connect (OSTI)

The Source Physics Experiment (SPE) will involve a series of explosions in various geologic and emplacement conditions to validate numerical simulation methods to predict behavior of seismic wave excitation and propagation for nuclear test monitoring. The first SPE's currently underway involve explosions in the Climax Stock (granitic geology) at the Nevada National Security Site (NNSS). Detailed geologic data and published material properties for the major lithologic units of the NNSS and surrounding region were used to build three-dimensional models for seismic wave propagation simulations. The geologic structure near the SPE shot point is quite varied including granitic, carbonate, tuff and alluvium lithologies. We performed preliminary ground motion simulations for a near-source domain covering 8 km x 8 km at the surface centered on the shot point to investigate various source and propagation effects using WPP, LLNL's anelastic seismic wave finite difference code. Simulations indicate that variations in wave propagation properties of the sub-surface will generate strongly path-dependent response once the energy has left the relatively small granitic geology of the near-surface Climax Stock near the SPE shot point. Rough topography to the north and west of SPE shot point causes additional complexity in the signals including energy on the transverse components. Waves propagate much faster through the granitic and carbonate formations and slower through the tuff and alluvium. Synthetic seismograms for a pure explosion source in a 3D geologic structure show large amplitudes on transverse component. For paths to the south sampling the granite, tuff and alluvium lithologies transverse component amplitudes are as high as 50% of that on the vertical and radial components.

Rodgers, A J; Wagoner, J; Petersson, N A; Sjogreen, B

2010-11-07T23:59:59.000Z

283

Pre-shot simulations of far-field ground motion for the Source Physics Experiment (SPE) Explosions at the Climax Stock, Nevada National Security Site: SPE2  

SciTech Connect (OSTI)

The Source Physics Experiment (SPE) is planning a 1000 kg (TNT equivalent) shot (SPE2) at the Nevada National Security Site (NNSS) in a granite borehole at a depth (canister centroid) of 45 meters. This shot follows an earlier shot of 100 kg in the same borehole at a depth 60 m. Surrounding the shotpoint is an extensive array of seismic sensors arrayed in 5 radial lines extending out 2 km to the north and east and approximately 10-15 to the south and west. Prior to SPE1, simulations using a finite difference code and a 3D numerical model based on the geologic setting were conducted, which predicted higher amplitudes to the south and east in the alluvium of Yucca Flat along with significant energy on the transverse components caused by scattering within the 3D volume along with some contribution by topographic scattering. Observations from the SPE1 shot largely confirmed these predictions although the ratio of transverse energy relative to the vertical and radial components was in general larger than predicted. A new set of simulations has been conducted for the upcoming SPE2 shot. These include improvements to the velocity model based on SPE1 observations as well as new capabilities added to the simulation code. The most significant is the addition of a new source model within the finite difference code by using the predicted ground velocities from a hydrodynamic code (GEODYN) as driving condition on the boundaries of a cube embedded within WPP which provides a more sophisticated source modeling capability linked directly to source site materials (e.g. granite) and type and size of source. Two sets of SPE2 simulations are conducted, one with a GEODYN source and 3D complex media (no topography node spacing of 5 m) and one with a standard isotropic pre-defined time function (3D complex media with topography, node spacing of 5 m). Results were provided as time series at specific points corresponding to sensor locations for both translational (x,y,z) and rotational components. Estimates of spectral scaling for SPE2 are provided using a modified version of the Mueller-Murphy model. An estimate of expected aftershock probabilities were also provided, based on the methodology of Ford and Walter, [2010].

Mellors, R J; Rodgers, A; Walter, W; Ford, S; Xu, H; Matzel, E; Myers, S; Petersson, N A; Sjogreen, B; Hauk, T; Wagoner, J

2011-10-18T23:59:59.000Z

284

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

of illuminance and temperature sensing with the Arduinoand internal view of Arduino microcontroller and associatedwas developed using the Arduino open-source electronics

Konis, Kyle Stas

2012-01-01T23:59:59.000Z

285

Effective Daylighting: Evaluating Daylighting Performance in the San Francisco Federal Building from the Perspective of Building Occupants  

E-Print Network [OSTI]

of illuminance and temperature sensing with the Arduinoand internal view of Arduino microcontroller and associatedwas developed using the Arduino open-source electronics

Konis, Kyle Stas

2011-01-01T23:59:59.000Z

286

To be submitted to Solar Energy. Daylight performance of a microstructured prismatic window film in deep open  

E-Print Network [OSTI]

To be submitted to Solar Energy. Daylight performance of a microstructured prismatic window film Systems Department, Environmental Energy Technologies Division, Lawrence Berkeley National Laboratory with vertical windows have the potential to offset lighting energy use in deep perimeter zones

287

Acceleration of the matrix multiplication of Radiance three phase daylighting simulations with parallel computing on heterogeneous hardware of personal computer  

SciTech Connect (OSTI)

Building designers are increasingly relying on complex fenestration systems to reduce energy consumed for lighting and HVAC in low energy buildings. Radiance, a lighting simulation program, has been used to conduct daylighting simulations for complex fenestration systems. Depending on the configurations, the simulation can take hours or even days using a personal computer. This paper describes how to accelerate the matrix multiplication portion of a Radiance three-phase daylight simulation by conducting parallel computing on heterogeneous hardware of a personal computer. The algorithm was optimized and the computational part was implemented in parallel using OpenCL. The speed of new approach was evaluated using various daylighting simulation cases on a multicore central processing unit and a graphics processing unit. Based on the measurements and analysis of the time usage for the Radiance daylighting simulation, further speedups can be achieved by using fast I/O devices and storing the data in a binary format.

University of Miami; Zuo, Wangda; McNeil, Andrew; Wetter, Michael; Lee, Eleanor S.

2013-04-30T23:59:59.000Z

288

Space, light, and time : prospective analysis of Circadian illumination for health-based daylighting with applications to healthcare architecture  

E-Print Network [OSTI]

Light in architecture can be studied for its objective or perceptual effects. This thesis describes an objective link between human health and architectural design. Specifically, the link between daylight and human circadian ...

Pechacek, Christopher S. (Christopher Scott)

2008-01-01T23:59:59.000Z

289

SOURCE?  

Energy Savers [EERE]

Department of Energy (DOE) in partnership with Lawrence Berkeley National Laboratory (LBNL), is an open-source code package designed to be a common, low-cost, standardized tool...

290

Origins of Analysis Methods Used to Design High Performance Commercial Buildings: Part III, Lighting and Daylighting Simulation  

E-Print Network [OSTI]

Origins of analysis methods used to design high performance commercial buildings: Part III, Lighting and daylighting simulation Sukjoon Oh Jeff S. Haberl Student Member ASHRAE Fellow ASHRAE This study is the third part of the review... methods used in lighting and daylighting simulation programs are described. In companion papers, the origins of the analysis methods of whole-building energy and solar energy analysis programs are reviewed(Oh and Haberl 2014a, 2014b). Introduction...

Oh, S.; Haberl, J.S.

291

Practical free-space quantum key distribution over 10 km in daylight and at night  

E-Print Network [OSTI]

We have demonstrated quantum key distribution (QKD) over a 10-km, 1-airmass atmospheric range during daylight and at night. Secret random bit sequences of the quality required for the cryptographic keys used to initialize secure communications devices were transferred at practical rates with realistic security. By identifying the physical parameters that determine the system's secrecy efficiency, we infer that free-space QKD will be practical over much longer ranges under these and other atmospheric and instrumental conditions.

Richard J. Hughes; Jane E. Nordholt; Derek Derkacs; Charles G. Peterson

2002-06-14T23:59:59.000Z

292

Alaska District, lab partner on cold regions work Subzero temperatures and limited daylight shorten the work season in northern regions. Add  

E-Print Network [OSTI]

Alaska District, lab partner on cold regions work Subzero temperatures and limited daylight shorten and innovative solutions in engineering, construction and operations in cold regions. The partnership between

US Army Corps of Engineers

293

Ground Water Ground Sky Sky Water Vegetation Ground Vegetation Water  

E-Print Network [OSTI]

Bear Snow Vegetation RhinoWater Vegetation Ground Water Ground Sky Sky Rhino Water Vegetation Ground Vegetation Water Rhino Water Vegetation Ground Rhino Water Rhino Water Ground Ground Vegetation Water Rhino Vegetation Rhino Vegetation Ground Rhino Vegetation Ground Sky Rhino Vegetation Ground Sky

Chen, Tsuhan

294

Measurements of volatile organic compounds at a suburban ground site (T1) in Mexico City during the MILAGRO 2006 campaign: Measurement comparison, emission ratios, and source attribution  

SciTech Connect (OSTI)

Volatile organic compound (VOC) mixing ratios were measured with two different instruments at the T1 ground site in Mexico City during the Megacity Initiative: Local and Global Research Observations (MILAGRO) campaign in March of 2006. A gas chromatograph with flame ionization detector (GC-FID) quantified 18 light alkanes, alkenes and acetylene while a proton-transfer-reaction ion-trap mass spectrometer (PIT-MS) quantified 12 VOC species including oxygenated VOCs (OVOCs) and aromatics. A GC separation system was used in conjunction with the PIT-MS (GC-PIT-MS) to evaluate PIT-MS measurements and to aid in the identification of unknown VOCs. The VOC measurements are also compared to simultaneous canister samples and to two independent proton-transfer-reaction mass spectrometers (PTR-MS) deployed on a mobile and an airborne platform during MILAGRO. VOC diurnal cycles demonstrate the large influence of vehicle traffic and liquid propane gas (LPG) emissions during the night and photochemical processing during the afternoon. Emission ratios for VOCs and OVOCs relative to CO are derived from early-morning measurements. Average emission ratios for non-oxygenated species relative to CO are on average a factor of {approx}2 higher than measured for US cities. Emission ratios for OVOCs are estimated and compared to literature values the northeastern US and to tunnel studies in California. Positive matrix factorization analysis (PMF) is used to provide insight into VOC sources and processing. Three PMF factors were distinguished by the analysis including the emissions from vehicles, the use of liquid propane gas and the production of secondary VOCs + long-lived species. Emission ratios to CO calculated from the results of PMF analysis are compared to emission ratios calculated directly from measurements. The total PIT-MS signal is summed to estimate the fraction of identified versus unidentified VOC species.

Bon, D.M.; Springston, S.; M.Ulbrich, I.; de Gouw, J. A.; Warneke, C.; Kuster, W. C.; Alexander, M. L.; Baker, A.; Beyersdorf, A. J.; Blake, D.; Fall, R.; Jimenez, J. L., Herndon, S. C.; Huey, L. G.; Knighton, W. B.; Ortega, J.; Vargas, O.

2011-03-16T23:59:59.000Z

295

Simulating the Daylight Performance of Complex Fenestration Systems Using Bidirectional Scattering Distribution Functions within Radiance  

SciTech Connect (OSTI)

We describe two methods which rely on bidirectional scattering distribution functions (BSDFs) to model the daylighting performance of complex fenestration systems (CFS), enabling greater flexibility and accuracy in evaluating arbitrary assemblies of glazing, shading, and other optically-complex coplanar window systems. Two tools within Radiance enable a) efficient annual performance evaluations of CFS, and b) accurate renderings of CFS despite the loss of spatial resolution associated with low-resolution BSDF datasets for inhomogeneous systems. Validation, accuracy, and limitations of the methods are discussed.

Ward, Gregory; Mistrick, Ph.D., Richard; Lee, Eleanor; McNeil, Andrew; Jonsson, Ph.D., Jacob

2011-01-21T23:59:59.000Z

296

Key word:Daylight Factor Window Wall Ratio Pendentive dome Lighting design Tropical region Architecture and Interior design  

E-Print Network [OSTI]

Abstract: Daylighting design plays important role in architecture of religious buildings such as churches and mosques where pendentive dome construction is frequently used. In daylighting design, many designers face difficulty in estimating the interior share of light which is usually expressed by daylight factor due to complexity of interior form. This study aims to provide designers with a rather high precision rule of thumb for average daylight factor in pendentive dome building. Thus, it investigates the Daylight Factor [DF] distribution of such buildings with reference to the tropics. It takes the Window Wall Ratio [WWR] into account and seeks its influence on daylight factor. By a 12 X 12 points grid, it examines five different ratios including 0.1, 0.2, 0.3, 0.4 and 0.5 on DF of the floor beneath the dome. The results endorse the direct relation of WWR and DF. The least WWR equal to 0.1 yields an average DF of 0.55 % while the greatest WWR of 0.5 yields in average DF of 2.56%. The intermediate WWR in steps of 0.2, 0.3 and 0.4 correspond to 1.04, 1.56 and 2.07 percent respectively. As a relatively precise rule of thumb, any increment in consequent steps of WWR with 0.1 intervals results in 0.5 % increase in DF. This can be employed by architects and interior designers for lighting design of pendentive dome buildings in tropical region.

Mehrdad Mazloomi

297

Empirical assessment of a prismatic daylight-redirecting window film in a full-scale office testbed  

SciTech Connect (OSTI)

Daylight redirecting systems with vertical windows have the potential to offset lighting energy use in deep perimeter zones. Microstructured prismatic window films can be manufactured using low-cost, roll-to-roll fabrication methods and adhered to the inside surface of existing windows as a retrofit measure or installed as a replacement insulating glass unit in the clerestory portion of the window wall. A clear film patterned with linear, 50-250 micrometer high, four-sided asymmetrical prisms was fabricated and installed in the south-facing, clerestory low-e, clear glazed windows of a full-scale testbed facility. Views through the film were distorted. The film was evaluated in a sunny climate over a two-year period to gauge daylighting and visual comfort performance. The daylighting aperture was small (window-towall ratio of 0.18) and the lower windows were blocked off to isolate the evaluation to the window film. Workplane illuminance measurements were made in the 4.6 m (15 ft) deep room furnished as a private office. Analysis of discomfort glare was conducted using high dynamic range imaging coupled with the evalglare software tool, which computes the daylight glare probability and other metrics used to evaluate visual discomfort. The window film was found to result in perceptible levels of discomfort glare on clear sunny days from the most conservative view point in the rear of the room looking toward the window. Daylight illuminance levels at the rear of the room were significantly increased above the reference window condition, which was defined as the same glazed clerestory window but with an interior Venetian blind (slat angle set to the cut-off angle), for the equinox to winter solstice period on clear sunny days. For partly cloudy and overcast sky conditions, daylight levels were improved slightly. To reduce glare, the daylighting film was coupled with a diffusing film in an insulating glazing unit. The diffusing film retained the directionality of the redirected light spreading it within a small range of outgoing angles. This solution was found to reduce glare to imperceptible levels while retaining for the most part the illuminance levels achieved solely by the daylighting film.

Thanachareonkit, Anothai; Lee, Eleanor S.; McNeil, Andrew

2013-08-31T23:59:59.000Z

298

Ground heat exchanger design for direct geothermal energy systems .  

E-Print Network [OSTI]

??Direct geothermal energy systems use the ground to heat and cool buildings. Ground-source heat pump (GSHP) systems are the most widespread form of direct geothermal… (more)

COLLS, STUART

2013-01-01T23:59:59.000Z

299

An experimental setup to evaluate the daylighting performance of an advanced optical light pipe for deep-plan office buildings  

E-Print Network [OSTI]

This research focuses on an advanced optical light pipe daylighting system as a means to deliver natural light at the back of deep-plan office buildings (15ft to 30ft), using optimized geometry and high reflective materials. The light pipe...

Martins Mogo de Nadal, Betina Gisela

2005-11-01T23:59:59.000Z

300

2003: Energy performance of daylight-linked automatic lighting control systems in large atrium spaces: report on two field-monitored case studies  

E-Print Network [OSTI]

This paper presents the field-measured energy performance of two common types of daylight-linked lighting control systems, continuous dimming and automatic on/off installed in two existing large atrium spaces located in Canada. The daylighting performance was evaluated based on the daylight contribution to the indoor illuminance and the amount of electrical lighting displaced by daylighting via the daylight-linked lighting control systems. Measured daylighting contribution to the space indicates that significant lighting energy savings can be achieved in atrium spaces if the daylight-linked lighting control system is appropriately selected, installed and commissioned throughout its existence. Results extrapolated from measurements collected during summer and winter indicate that as installed, the continuous dimming lighting control system provides 46% annual savings in electrical lighting consumption, while the automatic on/off saves between 11-17% in lighting energy. These savings account for 68% of the lighting energy consumed during main occupancy for the continuous dimming system, and 31.5% for the automatic on/off. Operation irregularities such as a reduced dimming linearity and an incorrect adjustment of the phases of the dimming control system, as well as the inadequate location of the photocell controlling the automatic on/off lighting system, the improper maintenance of the skylight during winter and the oversizing of the lighting system reduced the energy efficiency of the lighting control systems by 30-65%.

M. R. Galasiu; Morad R. Atif; Anca D. Galasiu

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Building America Case Study: Ground Source Heat Pump Research, TaC Studios Residence, Atlanta, Georigia (Fact Sheet), Technology Solutions for New and Existing Homes, Energy Efficiency & Renewable Energy (EERE)  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: ScopeDepartment1,Energy ForBryanREvaluation ofGround Source

302

The use of daylight in the design of a controlled environment for food production in the Caribbean and other equatorial climates  

E-Print Network [OSTI]

This thesis addresses the use of daylight in the design of a controlled environment for food production in the Caribbean and other Equatorial climates. An expanding population has put a tremendous burden on the food ...

Charles, Curtis B

1989-01-01T23:59:59.000Z

303

Roof aperture system for selective collection and control of solar energy for building heating, cooling and daylighting  

DOE Patents [OSTI]

The amount of building heating, cooling and daylighting is controlled by at least one pair of solar energy passing panels, with each panel of the pair of panels being exposed to a separate direction of sun incidence. A shutter-shade combination is associated with each pair of panels and the shutter is connected to the shade so that rectilinear movement of the shutter causes pivotal movement of the shade.

Sanders, William J. (Kansas City, KS); Snyder, Marvin K. (Overland Park, KS); Harter, James W. (Independence, MO)

1983-01-01T23:59:59.000Z

304

Energy Use Intensity and its Influence on the Integrated Daylighting Design of a Large Net Zero Energy Building: Preprint  

SciTech Connect (OSTI)

Net-zero energy buildings generate as much energy as they consume and are significant in the sustainable future of building design and construction. The role of daylighting (and its simulation) in the design process becomes critical. In this paper we present the process the National Renewable Energy Laboratory embarked on in the procurement, design, and construction of its newest building, the Research Support Facility (RSF) - particularly the roles of daylighting, electric lighting, and simulation. With a rapid construction schedule, the procurement, design, and construction had to be tightly integrated; with low energy use. We outline the process and measures required to manage a building design that could expect to operate at an efficiency previously unheard of for a building of this type, size, and density. Rigorous simulation of the daylighting and the electric lighting control response was a given, but the oft-ignored disconnect between lighting simulation and whole-building energy use simulation had to be addressed. The RSF project will be thoroughly evaluated for its performance for one year; preliminary data from the postoccupancy monitoring efforts will also be presented with an eye toward the current efficacy of building energy and lighting simulation.

Guglielmetti , R.; Scheib, J.; Pless, S. D.; Torcellini , P.; Petro, R.

2011-03-01T23:59:59.000Z

305

Evaluation of Analytical and Numerical Techniques for Defining the Radius of Influence for an Open-Loop Ground Source Heat Pump System  

SciTech Connect (OSTI)

In an open-loop groundwater heat pump (GHP) system, groundwater is extracted, run through a heat exchanger, and injected back into the ground, resulting in no mass balance changes to the flow system. Although the groundwater use is non-consumptive, the withdrawal and injection of groundwater may cause negative hydraulic and thermal impacts to the flow system. Because GHP is a relatively new technology and regulatory guidelines for determining environmental impacts for GHPs may not exist, consumptive use metrics may need to be used for permit applications. For consumptive use permits, a radius of influence is often used, which is defined as the radius beyond which hydraulic impacts to the system are considered negligible. In this paper, the hydraulic radius of influence concept was examined using analytical and numerical methods for a non-consumptive GHP system in southeastern Washington State. At this location, the primary hydraulic concerns were impacts to nearby contaminant plumes and a water supply well field. The results of this study showed that the analytical techniques with idealized radial flow were generally unsuited because they over predicted the influence of the well system. The numerical techniques yielded more reasonable results because they could account for aquifer heterogeneities and flow boundaries. In particular, the use of a capture zone analysis was identified as the best method for determining potential changes in current contaminant plume trajectories. The capture zone analysis is a more quantitative and reliable tool for determining the radius of influence with a greater accuracy and better insight for a non-consumptive GHP assessment.

Freedman, Vicky L.; Mackley, Rob D.; Waichler, Scott R.; Horner, Jacob A.

2013-09-26T23:59:59.000Z

306

Comparative Study of summer, Winter and Quinox Sky Type of India Using Daylight Coefficient Method and Cie Standard General Sky Model  

E-Print Network [OSTI]

Abstract:- Energy efficiency provided by daylight requires an accurate estimation of the amount of daylight entering a building. The actual daylight illuminance of a room is mainly influenced by the luminance levels and patterns of the sky in the direction of view of the window at that time. The daylight coefficient concept, which considers the changes in the luminance of the sky elements, offers a more effective way of computing indoor daylight illuminances. Recently, Kittler et al. have proposed a new range of 15 standard sky luminance distributions including the CIE (International Commission onIllumination) standard clear sky. Lately, these 15 sky luminance models have been adopted as the CIE Standard General Skies.This paper aims to find out representative CIE (International Commission on Illumination) Standard Clear Sky model(s) for three different seasons-winter solstice, equinox, and summer solstice applicable for prevailing clear sky climatic conditions in India [Roorkee]. Indian measured sky luminance distribution database is available only for Roorkee[29 0 51 ' N; 77 0 53 ' E]. To find out the best match between Indian measured sky luminance distribution and each of five CIE Standard Clear sky models, only sky component of spatial illuminance distribution over the working plane of a room was simulated by MATLABfor three different seasons. Daylight Coefficient method has been applied for the simulation using Indian sky luminance database.The simulation has been done for the room with eight different window orientations ranging from 0 0 to 315 0 with an interval of 45 0 to generate data for the entire sky vault. To find out the

Sutapa Mukherjee M. Tech

307

E-Print Network 3.0 - achieving ground state Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

by their frequency or polarization upon decay to their respective ground states. Preliminary... isotope 137 Ba+ whose nuclear spin leads to ground state ... Source:...

308

Factors controlling tungsten concentrations in ground water, Carson Desert, Nevada  

E-Print Network [OSTI]

Factors controlling tungsten concentrations in ground water, Carson Desert, Nevada Ralph L. Seiler sources. Tungsten concentrations in 100 ground water samples from all aquifers used as drinking water indicates that W exhibits Tungsten con- centrations are strongly and positively correlated

309

Ground Loops for Heat Pumps and Refrigeration  

E-Print Network [OSTI]

Ground loops are used for water source heat pumps. Refrigeration can be put on a ground loop. Water-cooled condensing units are more efficient than air-cooled, and they can be put indoors. Indoor location makes piping for desuperheater hot water...

Braud, H. J.

1986-01-01T23:59:59.000Z

310

Ground Source Heat Pumps | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to: navigation,Ohio:Greer County is a county inAl., 1979) |Haar, 1986)EnergyOpenPumps

311

Ground Source Heat Pumps | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to: navigation,Ohio:Greer County is a county inAl., 1979) |Haar,

312

A significant number of Iowa water treatment systems are dependent upon well-based water sources. Because of this, CIRAS efforts have been focused on the "Ground Water Levels" as reported by Iowa DNR. Currently, DNR officials are indicating that restricti  

E-Print Network [OSTI]

A significant number of Iowa water treatment systems are dependent upon well-based water sources. Because of this, CIRAS efforts have been focused on the "Ground Water Levels" as reported by Iowa DNR. Currently, DNR officials are indicating that restrictions or loss of the water supply is not likely

Lin, Zhiqun

313

A SIMULATION ASSESSMENT OF THE HEIGHT OF LIGHT SHELVES TO ENHANCE DAYLIGHTING QUALITY IN TROPICAL OFFICE BUILDINGS UNDER OVERCAST SKY CONDITIONS IN DHAKA, BANGLADESH  

E-Print Network [OSTI]

The objective of this paper is to highlight the effectiveness of light shelves in tropical office buildings to enhance interior daylighting quality. Daylight simulation was performed for custom light shelves for a typical office floor of Dhaka City in Bangladesh, to determine the best possible location under overcast sky conditions. Six alternative models of a 3m high study space were created with varying heights of light shelves. The 3D models were first generated in the Ecotect to study the distribution and uniformity of daylight in the interior space with splitflux method. These models were then exported to a physically-based backward raytracer, Radiance Synthetic Imaging software to generate realistic lighting levels for validating and crosschecking the Ecotect results. The results showed that for achieving light levels closest to specified standards, light shelves at a height of 2m above floor level perform better among the seven alternatives studied including the alternative where no light shelves are present. Finally, the decisions were verified with DAYSIM simulation program to ensure the compliance of the decisions with dynamic annual climate-based daylight performance metrics.

Md. Ashikur; Rahman Joarder; Zebun Nasreen Ahmed; Andrew Price; Monjur Mourshed

314

Demonstration with Energy and Daylighting Assessment of Sunlight Responsive Thermochromic (SRT) Window Systems  

SciTech Connect (OSTI)

Pleotint, LLC was able to successfully extrude thermochromic interlayer for use in the fenestration industry. Pleotint has developed a thermochromic sytem that requires two thermochromic colors to make a neutral color when in the tinted state. These two colors were assembled into a single interlayer called a tri-layer prelam by Crown Operations for use in the glass lamination industry. Various locations, orientations, and constructions of thermochromic windows were studied with funds from this contract. Locations included Australia, California, Costa Rica, Indiana, Iowa, Mexico. Installed orientations included vertical and skylight glazing applications. Various constructions included monolithic, double pane, triple pane constructions. A daylighting study was conducted at LinEl Signature. LinEl Signature has a conference room with a sylight roof system that has a west orientation. The existing LinEl Signature conference room had constant tint 40% VLT transparent skylights. Irradiance meters were installed on the interior and exterior sides of a constant tint skylight. After a month and a half of data collection, the irradiance meters were removed and the constant tint skylights were replaced with Pleotint thermochromic skylight windows. The irradiance meters were reinstalled in the same locations and irradiance data was collected. Both data sets were compared. The data showed that there was a linear relationship with exterior and interior irradiance for the existing constant tint skylights. The thermochromic skylights have a non-linear relationship. The thermochromic skylights were able to limit the amount of irradiance that passed through the thermochromic skylight. A second study of the LinEl Signature conference was performed using EnergyPlus to calculate the amount of Illuminance that passed through constant tint skylights as compared to thermochromic skylights. The constant tint skylights transmitted Illuminance is 2.8 times higher than the thermochromic skylights during the months of May, June, July, August and 1.9 times higher than the thermochromic skylight during the months of March, April, September, October. Calculated illuminance levels were much more consistent as compared to the existing constant tint skylights installed at LinEl Signature. This allows for a more comfortable interior space in regard to glare discomfort and interior lighting control. Lawrence Berkeley National Laboratory was contracted to characterize the performance of the thermochromic interlayer and thermochromic window systems. Thermochromic interlayer was characterized with spectrometer equipment. The thermochromic window systems were characterized using LBNL’s Advanced Window Test Facility. A copy of the report can be found in the Appendix. Iowa State University was contracted to compare thermochromic window technology to constant tint technology. Iowa State University conducted the testing at the Energy Resource Station (ERS). The ERS has the ability to simultaneously test side-by-side competing building technologies. The building is equipped with two identical air handling units, each with its own dedicated and identical chiller. One air handling unit supplies the four test rooms designated as the A rooms and the other unit serves the four test rooms designated as the B rooms. There is one A test room and one B test rooms arranged as pairs in a side-by-side design with each pair having a different exposure. There is a pair of test rooms that face the south, an east and west facing pair. Each of the test rooms is a mirror image of its match with identical construction. The rooms are unoccupied; however, the capability to impose false loads on the rooms exists. The false loads and room lighting can be scheduled to simulate various usage patterns. A copy of the report can be found in the Appendix. GARD Analytics was contracted to compare EnergyPlus building simulations to the data recorded at the Iowa ERS. The goal of this research was to validate the building simulation software developed by the US Department of Energy. EnergyPlus is

Broekhuis, Michael; Liposcak, Curtis; Witte, Michael; Henninger, Robert; Zhou, Xiaohui; Petzen, George; Buchanan, Michael; Kumar, Sneh

2012-03-31T23:59:59.000Z

315

The LOFT Ground Segment  

E-Print Network [OSTI]

LOFT, the Large Observatory For X-ray Timing, was one of the ESA M3 mission candidates that completed their assessment phase at the end of 2013. LOFT is equipped with two instruments, the Large Area Detector (LAD) and the Wide Field Monitor (WFM). The LAD performs pointed observations of several targets per orbit (~90 minutes), providing roughly ~80 GB of proprietary data per day (the proprietary period will be 12 months). The WFM continuously monitors about 1/3 of the sky at a time and provides data for about ~100 sources a day, resulting in a total of ~20 GB of additional telemetry. The LOFT Burst alert System additionally identifies on-board bright impulsive events (e.g., Gamma-ray Bursts, GRBs) and broadcasts the corresponding position and trigger time to the ground using a dedicated system of ~15 VHF receivers. All WFM data are planned to be made public immediately. In this contribution we summarize the planned organization of the LOFT ground segment (GS), as established in the mission Yellow Book 1 . We...

Bozzo, E; Argan, A; Barret, D; Binko, P; Brandt, S; Cavazzuti, E; Courvoisier, T; Herder, J W den; Feroci, M; Ferrigno, C; Giommi, P; Götz, D; Guy, L; Hernanz, M; Zand, J J M in't; Klochkov, D; Kuulkers, E; Motch, C; Lumb, D; Papitto, A; Pittori, C; Rohlfs, R; Santangelo, A; Schmid, C; Schwope, A D; Smith, P J; Webb, N A; Wilms, J; Zane, S

2014-01-01T23:59:59.000Z

316

Renewable Energy Opportunities at Yuma Proving Ground, Arizona  

SciTech Connect (OSTI)

This document provides an overview of renewable resource potential at Yuma Proving Ground, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations.

Orrell, Alice C.; Kora, Angela R.; Russo, Bryan J.; Williamson, Jennifer L.; Weimar, Mark R.; Gorrissen, Willy J.; Dixon, Douglas R.

2010-06-30T23:59:59.000Z

317

Predaceous Ground Beetles  

E-Print Network [OSTI]

Predaceous Ground Beetles Caterpillar Hunters and Bombardier Beetles Rick Minzenmayer, Extension Agent-IPM Chris Sansone, Extension Entomologist Texas Cooperative Extension genus Calosoma, a brightly colored ground beetle. Some species are called...

Sansone, Chris; Minzenmayer, Rick

2003-06-30T23:59:59.000Z

318

Ground Turkey Stroganoff Ingredients  

E-Print Network [OSTI]

Ground Turkey Stroganoff Ingredients: 8 ounces egg noodles, uncooked 1 pound ground turkey 1 onion. Meanwhile, brown ground turkey and onions in non stick skillet until meat is no longer pink and onions cup of egg noodles on plate, top with 1/2 cup of turkey mixture. Equipment: Knife Cutting board

Liskiewicz, Maciej

319

Cooking with Ground Pork  

E-Print Network [OSTI]

to thaw. Even when cooked, pork that has been thawed at room temperature can make you sick. Cooking ground pork safely For dishes that contain ground pork, cook the pork before mixing it with other ingredients. How to store cooked ground pork Leftover... dishes made with ground pork should be stored in a covered dish in the refrigerator right away to prevent spoilage. Use it within 3 days. Reheat foods with ground pork until they are steaming hot, bubbling, or at 165 degrees. Other uses Use cooked...

Anding, Jenna

2008-12-09T23:59:59.000Z

320

Ground Water Management Act (Virginia)  

Broader source: Energy.gov [DOE]

Under the Ground Water Management Act of 1992, Virginia manages ground water through a program regulating the withdrawals in certain areas called Ground Water Management Areas (GWMA). Currently,...

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 3, is a users manual and an installation and validation manual for the computer program SGSYS (Substation Grounding SYStem Analysis Program). This program analyzes the substation ground field given the total electric current injected into the ground field and the design of the grounding system. Standard outputs of the program are (1) total ground resistance, (2) step voltage, (3) touch voltage, (4) voltages on a grid of points, (5) voltage profile along straight lines, (6) transfer voltages, (7) ground potential rise, (8) body currents, (9) step voltage profile along straight lines, and (10) touch voltage profile along straight lines. This program can be utilized in an interactive or batch mode. In the interactive mode, the user defines the grounding system geometry, soil parameters, and output requests interactively, with the use of a user friendly conversational program. The users manual describes data requirements and data preparation procedures. An appendix provides forms which facilitate data collection procedures. The installation and validation manual describes the computer files which make up the program SGSYS and provides a test case for validation purposes.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

322

Cooking with Ground Beef  

E-Print Network [OSTI]

This fact sheet describes the nutritional value and safe storage of ground beef, a commodity food. It also offers food preparation ideas....

Anding, Jenna

2008-12-09T23:59:59.000Z

323

Renewable Energy Opportunties at Dugway Proving Ground, Utah  

SciTech Connect (OSTI)

This document provides an overview of renewable resource potential at Dugway Proving Ground, based primarily upon analysis of secondary data sources supplemented with limited on-site evaluations. This effort focuses on grid-connected generation of electricity from renewable energy sources and ground source heat pumps (GSHPs). The effort was funded by the U.S. Army Installation Management Command (IMCOM) as follow-on to the 2005 Department of Defense (DoD) Renewables Assessment.

Orrell, Alice C.; Kora, Angela R.; Russo, Bryan J.; Horner, Jacob A.; Williamson, Jennifer L.; Weimar, Mark R.; Gorrissen, Willy J.; Nesse, Ronald J.; Dixon, Douglas R.

2010-05-31T23:59:59.000Z

324

Ground State Quantum Computation  

E-Print Network [OSTI]

We formulate a novel ground state quantum computation approach that requires no unitary evolution of qubits in time: the qubits are fixed in stationary states of the Hamiltonian. This formulation supplies a completely time-independent approach to realizing quantum computers. We give a concrete suggestion for a ground state quantum computer involving linked quantum dots.

Ari Mizel; M. W. Mitchell; Marvin L. Cohen

1999-08-11T23:59:59.000Z

325

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. It can be used to compute transient ground potential rise due to lightning or switching, and the ground impedance (i.e. resistance and reactance) at specified frequencies. This report, Volume 4, is a users manual and an installation and validation manual for the computer program TGRND (Transient GRouNDing System Analysis Program). This program computes transient ground potential rise resulting from lightning, switching, or other transient electric currents injected to a grounding system. The program also computes the impedance (i.e. resistance and reactance) of a grounding system as a function of frequency. This program can be utilized in an interactive or batch mode. The users manual describes data requirements and data preparation procedures. The installation and validation manual describes the computer files which make up the program TGRND and provides a test case for validation purposes.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

326

DC source assemblies  

DOE Patents [OSTI]

Embodiments of DC source assemblies of power inverter systems of the type suitable for deployment in a vehicle having an electrically grounded chassis are provided. An embodiment of a DC source assembly comprises a housing, a DC source disposed within the housing, a first terminal, and a second terminal. The DC source also comprises a first capacitor having a first electrode electrically coupled to the housing, and a second electrode electrically coupled to the first terminal. The DC source assembly further comprises a second capacitor having a first electrode electrically coupled to the housing, and a second electrode electrically coupled to the second terminal.

Campbell, Jeremy B; Newson, Steve

2013-02-26T23:59:59.000Z

327

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 2, is a users manual and an installation and validation manual for the computer program SMECC (Substation Maximum Earth Current Computation Program). This program analyzes the electric current distribution among grounded structures inside and outside a substation for different fault conditions. The fault conditions are automatically selected by the program, or they may be specified by the user, or both. The fault condition resulting in maximum substation earth current is identified and reported. Data requirements for this program are: ground impedance, transformer data, transmission line data, transmission line grounding impedances, etc. The program provides four types of standard outputs: (1) a report of voltages and current flow in the unfaulted system, (2) a brief report of the maximum ground potential rise (worst fault condition), (3) a summary report of all fault conditions which have been analyzed by the program, and (4) a detailed report of voltages and current flow for a selected set of fault conditions.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

328

Substation grounding programs  

SciTech Connect (OSTI)

This document is a users manual and applications guide for the software package SGA. This package comprises four computer programs, namely SOMIP, SMECC, SGSYS, and TGRND. The first three programs are analysis models which are to be used in the design process of substation grounding systems. The fourth program, TGRND, is an analysis program for determining the transient response of a grounding system. This report, Volume 5, is an applications guide of the three computer programs. SOMIP, SMECC, and SGSYS, for the purpose of designing a safe substation grounding system. The applications guide utilizes four example substation grounding systems for the purpose of illustrating the application of the programs, SOMIP, SMECC, and SGSYS. The examples are based on data provided by four contributing utilities, namely, Houston Lighting and Power Company, Southern Company Services, Puget Sound Power and Light Company, and Arizona Public Service Company. For the purpose of illustrating specific capabilities of the computer programs, the data have been modified. As a result, the final designs of the four systems do not necessarily represent actual grounding system designs by these utilities. The example system 1 is a 138 kV/35 kV distribution substation. The example system 2 is a medium size 230 kV/115 kV transmission substation. The third example system is a generation substation while the last is a large 525 kV/345 kV/230 kV transmission substation. The four examples cover most of the practical problems that a user may encounter in the design of substation grounding systems.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). Electric Power Lab.)

1992-05-01T23:59:59.000Z

329

E-Print Network 3.0 - above-and below- ground Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

a foam Graphic 3: Below-ground parking structure in Chicago, IL being backfilled with EPS-geofoam blocks Source: Horvath, John S. - Civil and Environmental Engineering...

330

E-Print Network 3.0 - alkaline ground waters Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

water from the Lake Calumet... , and ground ... Source: Bethke, Craig - Department of Geology, University of Illinois at Urbana-Champaign Collection: Environmental Sciences and...

331

THE DAYLIGHTING SOLUTION  

E-Print Network [OSTI]

Secretary for Conservation and Solar Energy, Office ofSecretary for Conservation and Solar Energy, Office of

Selkowitz, Stephen

2013-01-01T23:59:59.000Z

332

Daylighting | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) " ,"ClickPipelinesProvedDecember 2005Department ofDOE AccidentWaste IsolationDashboardsDavid

333

Window Daylighting Demo  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of| Department ofDepartment ofAnnouncementAugust 30,PowerJuneenabledandWindow

334

Substation grounding programs  

SciTech Connect (OSTI)

The five volume report comprises the user manual, installation, and validation manual and an applications guide for the SGA (Substation Grounding Analysis) software package. SGA consists of four computer programs: (1) SOMIP, (2) SMECC, (3) SGSYS, and (4) TGRND. The first three programs provide a comprehensive analysis tool for the design of substation grounding systems to meet safety standards. The fourth program, TGRND, provides a state of the art analysis tool for computing transient ground potential rise and ground system impedance. This part of the report, Volume 1, is a users manual and an installation and validation manual for the computer program SOMIP (SOil Measurement Interpretation Program). This program computes the best estimate of the parameters of a two layer soil model from usual soil resistivity measurements. Four pin or three pin soil measurements can be accommodated. In addition, it provides error bounds on the soil parameters for a given confidence level. The users manual describes data requirements and data preparation procedures. The installation and validation manual describes the computer files which make up the program SOMIP and provides two test cases for validation purposes. 4 refs.

Meliopoulos, A.P.S. (Georgia Inst. of Tech., Atlanta, GA (United States). School of Electrical Engineering)

1992-05-01T23:59:59.000Z

335

GROUND WATER CONTAMINATION  

SciTech Connect (OSTI)

As required by the terms of the above referenced grant, the following summary serves as the Final Report for that grant. The grant relates to work performed at two separate sites, the Hoe Creek Underground Coal Gasification Site south of Gillette, Wyoming, and the Rock Springs In-Situ Oil Shale Retort Site near Rock Springs, Wyoming. The primary concern to the State of Wyoming at each site is ground water contamination (the primary contaminants of concern are benzene and related compounds), and the purpose of the grant has been to provide tiding for a Geohydrologist at the appropriate State agency, specifically the Land Quality Division (LQD) of the Wyoming Department of Environmental Quality. The LQD Geohydrologist has been responsible for providing technical and regulatory support to DOE for ground water remediation and subsequent surface reclamation. Substantial progress has been made toward remediation of the sites, and continuation of LQD involvement in the remediation and reclamation efforts is addressed.

Unknown

1999-09-01T23:59:59.000Z

336

Unattended ground sensor situation assessment workstation  

SciTech Connect (OSTI)

Effective utilization of unattended ground sensors (UGSs) in a theater reconnaissance, surveillance, target acquisition, and kill assessment environment requires that a human operator be able to interpret, and collectively assess, the significance of real time data obtained from UGS emplacements over large geographical regions of interest. The products of this UGS data interpretation and assessment activity can then be used in the decision support process for command level evaluation of appropriate courses of action. Advancements in both sensor hardware technology and in software systems and processing technology have enabled the development of practical real time situation assessment capabilities based upon information from unattended ground sensors. A decision support workstation that employs rule-based expert system processing of reports from unattended ground sensors is described. The primary goal of this development activity is to produce a suite of software to track vehicles using data from unattended ground sensors. The situational assessment products from this system have stand-alone utility, but are also intended to provide cueing support for overhead sensors and supplementary feeds to all-source fusion centers. The conceptual framework, developmental architecture, and demonstration field tests of the system are described.

Jeppesen, D.; Trellue, R.

1997-04-01T23:59:59.000Z

337

SRS Burial Ground Complex: Remediation in Progress  

SciTech Connect (OSTI)

Closure of the various areas in the Burial Ground Complex (BGC) represents a major step in the reduction of risk at the Savannah River Site (SRS) and a significant investment of resources. The Burial Ground Complex occupies approximately 195 acres in the central section of the SRS. Approximately 160 acres of the BGC consists of hazardous and radioactive waste disposal sites that require remediation. Of these source acres, one-third have been remediated while two-thirds are undergoing interim or final action. These restoration activities have been carried out in a safe and cost effective manner while minimizing impact to operating facilities. Successful completion of these activities is in large part due to the teamwork demonstrated by the Department of Energy, contractor/subcontractor personnel, and the regulatory agencies. The experience and knowledge gained from the closure of these large disposal facilities can be used to expedite closure of similar facilities.

Griffin, M. [Westinghouse Savannah River Company, AIKEN, SC (United States); Crapse, B.; Cowan, S.

1998-01-21T23:59:59.000Z

338

Ground potential rise monitor  

DOE Patents [OSTI]

A device and method for detecting ground potential rise (GPR) comprising positioning a first electrode and a second electrode at a distance from each other into the earth. The voltage of the first electrode and second electrode is attenuated by an attenuation factor creating an attenuated voltage. The true RMS voltage of the attenuated voltage is determined creating an attenuated true RMS voltage. The attenuated true RMS voltage is then multiplied by the attenuation factor creating a calculated true RMS voltage. If the calculated true RMS voltage is greater than a first predetermined voltage threshold, a first alarm is enabled at a local location. If user input is received at a remote location acknowledging the first alarm, a first alarm acknowledgment signal is transmitted. The first alarm acknowledgment signal is then received at which time the first alarm is disabled.

Allen, Zachery W. (Mandan, ND); Zevenbergen, Gary A. (Arvada, CO)

2012-04-03T23:59:59.000Z

339

Coal mine ground control. 3rd ed.  

SciTech Connect (OSTI)

The third edition not only completely revises and updates the original subject areas, but also is broadened to include a number of new topics such as high horizontal stresses, computer modeling, and highwall stability. The subject areas covered in this book define the current field of coal mine ground control, except for the recently emerging topic of mine seals and some conventional subjects such as coal/rock cutting and impoundment dams. It contains 1,134 references from all published sources, and archived since 1876.

Peng, S.S.

2008-09-15T23:59:59.000Z

340

Tennessee: Ground-Source Heat Pump Receives Innovation Award...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

equipment and greater than 30% versus current state-of-the-art two-stage geothermal heat pumps. This water-to-air packaged heat pump provides significantly lower energy...

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

National Certification Standard for Ground Source Heat Pump Personnel  

SciTech Connect (OSTI)

The National Certification Standard for the Geothermal Heat Pump Industry adds to the understanding of the barriers to rapid growth of the geothermal heat pump (GHP) industry by bringing together for the first time an analysis of the roles and responsibilities of each of the individual job tasks involved in the design and installation of GHP systems. The standard addresses applicable qualifications for all primary personnel involved in the design, installation, commissioning, operation and maintenance of GHP systems, including their knowledge, skills and abilities. The resulting standard serves as a foundation for subsequent development of curriculum, training and certification programs, which are not included in the scope of this project, but are briefly addressed in the standard to describe ways in which the standard developed in this project may form a foundation to support further progress in accomplishing those other efforts. Follow-on efforts may use the standard developed in this project to improve the technical effectiveness and economic feasibility of curriculum development and training programs for GHP industry personnel, by providing a more complete and objective assessment of the individual job tasks necessary for successful implementation of GHP systems. When incorporated into future certification programs for GHP personnel, the standard will facilitate increased consumer confidence in GHP technology, reduce the potential for improperly installed GHP systems, and assure GHP system quality and performance, all of which benefit the public through improved energy efficiency and mitigated environmental impacts of the heating and cooling of homes and businesses.

Kelly, John [Geothermal Heat Pump Consortium] [Geothermal Heat Pump Consortium

2013-07-31T23:59:59.000Z

342

Optimal Ground-Source Heat Pump System Design  

Broader source: Energy.gov [DOE]

Project objectives: Develop a least-cost design tool (OptGSHP) that will enable GSHP developers to analyze system cost and performance in a variety of building applications to support both design, operational and purchase decisions. Integrate groundwater flow and heat transport into OptGSHP. Demonstrate the usefulness of OptGSHP and the significance of a systems approach to the design of GSHP systems.

343

Technical Feasibility Study for Deployment of Ground-Source Heat...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

encountered within both the (1) moderately-to-high permeability, pore- dominated, unconsolidated overburden and fill and (2) lower permeability, fracture-dominated bedrock at PNSY...

344

Ground Source Heat Pump Demonstration Projects | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:

345

Ground Source Heat Pump System Data Analysis | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector General Office0-72.pdfGeorge Waldmann GeorgeLogging Systems (DecemberGREENINGSenate

346

Data Analysis from Ground Source Heat Pump Demonstration Projects |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeat Pump Models | Department1 Prepared by:DTE Energy VideoDark Matter and a

347

Ball State University Completes Nation's Largest Ground-Source Geothermal  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3--Logistical5/08 Attendance List1-02EvaluationJohn

348

Hybrid Ground Source System Analysis and Tool Development  

Broader source: Energy.gov [DOE]

Project objectives: 1. Compile filtered hourly data for three monitored hybrid installations. 2.Validate existing HyGCHP model. 3.Refine and enhance the HyGCHP model (usability / capability). 4. Demonstrate impact of actual hybrid installations. 5. Report lessons learned and impacts of HyGSHPs to design/engineering community.

349

OpenStudio Enhancements for Whole-building Daylighting, Airflow, and Energy Modeling Leveraging Interoperable BIM Data for SMSCB  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l L d F SSales LLCDiesel Engines |Open Source Software Messner,

350

Experimental analysis on a 1:2 scale model of the double light pipe, an innovative technological device for daylight transmission  

SciTech Connect (OSTI)

In this paper the authors present the double light pipe, an innovative technological device, designed as an evolution of a traditional light pipe, which distributes daylight to underground areas of a building, illuminating, at the same time, the passage areas thanks to a larger collector and a second transparent pipe attached to the first one. Unlike the traditional light pipe, thanks to this double illuminating function it can be located in the middle of a room, despite its encumbrance. In this paper the technological design of the double light pipe is presented and the results of an experimental analysis on a reduced scale (1:2) model are shown. Internal illuminance data over horizontal and vertical work-planes were measured in various sky conditions with or without direct solar radiation. Being this innovative device obtained by a light pipe integrated with a second pipe, it performs like a traditional light pipe for the final room and, at the same time, illuminates the intermediate room giving it uniform and high quality light, particularly indicated for wide plant areas, such as show-rooms or museums. (author)

Baroncini, C.; Boccia, O.; Chella, F.; Zazzini, P. [D.S.S.A.R.R. Faculty of Architecture, University ''G. D'Annunzio'' Viale Pindaro 42, 65127 Pescara (Italy)

2010-02-15T23:59:59.000Z

351

QUEENSLAND UNIVERSITY OF TECHNOLOGY CENTRE FOR MEDICAL, HEALTH AND ENVIRONMENTAL PHYSICS SCHOOL OF PHYSICAL AND CHEMICAL SCIENCES MODIFICATION OF ATRIUM DESIGN TO IMPROVE THERMAL AND DAYLIGHTING PERFORMANCE  

E-Print Network [OSTI]

The inclusion of a central court or atrium within a building is a popular design due to its aesthetic, open appearance. The greater penetration of natural light aids in the reduction in use of artificial lighting during the day. Care must be taken to balance the solar heat gain against the daylight penetration. This balance is critical for the reduction of the electrical energy load of the building, whilst maintaining a high level of comfort for the occupants. In the tropics modifications to atrium building designs are necessary to diminish high elevation direct solar heat gain. Traditionally, shading the window apertures or lowering the transmission through the glazing was used. These solutions limit the view and reduce the light level. The use of angular selective glazing upon atria allows the rejection of high elevation direct sunlight whilst redirecting and therefore improving low elevation skylight penetration. Tilted angular selective glazing used upon adjoining spaces to atria help vertical light in the atrium well to be redirected horizontally deep into the space. These effects reduce overheating which would normally restrict the use of atria in warmer environments as well as improve illumination penetration into adjoining spaces.

Ashley Mabb; Centre For Medical; Environmental Physics

352

Ground Turkey Stir Fry Ingredients  

E-Print Network [OSTI]

Ground Turkey Stir Fry Ingredients: 1 1/2 cups brown rice, medium- grain, making 3 cups cooked 1 pound ground turkey 4 zucchini 1 onion 1 green pepper 1/4 teaspoon pepper Directions 1. Cook brown rice turkey in skillet and use a spatula to break beef into small pieces as it browns. Keep on stirring

Liskiewicz, Maciej

353

GLAST and Ground-Based Gamma-Ray Astronomy  

SciTech Connect (OSTI)

The launch of the Gamma-ray Large Area Space Telescope (GLAST) in 2007 will open the possibility of combined studies of astrophysical sources with existing ground-based VHE {gamma}-ray experiments such as H.E.S.S., VERITAS and MAGIC. Ground-based {gamma}-ray observatories provide complementary capabilities for spectral, temporal, spatial and population studies of high-energy {gamma}-ray sources. Joint observations cover a huge energy range, from 20 MeV to over 50 TeV. The LAT will survey the entire sky every three hours, allowing us to perform long-term monitoring of variable sources under uniform observation conditions and to detect flaring sources promptly. Imaging atmospheric Cherenkov telescopes (IACTs) will complement these observations with high-sensitivity pointed observations on regions of interest.

Funk, S.; Carson, J.E.; Giebels, B.; Longo, F.; McEnery, J.E.; Paneque, D.; Reimer, O.; Reyes, L.C.

2007-10-10T23:59:59.000Z

354

Regional analysis of ground and above-ground climate  

SciTech Connect (OSTI)

The regional suitability of underground construction as a climate control technique is discussed with reference to (1) a bioclimatic analysis of long-term weather data for 29 locations in the United States to determine appropriate above ground climate control techniques, (2) a data base of synthesized ground temperatures for the coterminous United States, and (3) monthly dew point ground temperature comparisons for identifying the relative likelihood of condensation from one region to another. It is concluded that the suitability of earth tempering as a practice and of specific earth-sheltered design stereotypes varies geographically; while the subsurface almost always provides a thermal advantage on its own terms when compared to above ground climatic data, it can, nonetheless, compromise the effectiveness of other, regionally more important climate control techniques. Also contained in the report are reviews of above and below ground climate mapping schemes related to human comfort and architectural design, and detailed description of a theoretical model of ground temperature, heat flow, and heat storage in the ground. Strategies of passive climate control are presented in a discussion of the building bioclimatic analysis procedure which has been applied in a computer analysis of 30 years of weather data for each of 29 locations in the United States.

Not Available

1981-12-01T23:59:59.000Z

355

COMPARATIVE STUDY AMONG HYBRID GROUND SOURCE HEAT PUMP SYSTEM, COMPLETE GROUND SOURCE HEAT PUMP AND CONVENTIONAL HVAC SYSTEM  

SciTech Connect (OSTI)

In this paper, a hotel with hybrid geothermal heat pump system (HyGSHP) in the Pensacola is selected and simulated by the transient simulation software package TRNSYS [1]. To verify the simulation results, the validations are conducted by using the monthly average entering water temperature, monthly facility consumption data, and etc. And three types of HVAC systems are compared based on the same building model and HVAC system capacity. The results are presented to show the advantages and disadvantages of HyGSHP compared with the other two systems in terms of energy consumptions, life cycle cost analysis.

Jiang Zhu; Yong X. Tao

2011-11-01T23:59:59.000Z

356

Acoustic and Seismic Modalities for Unattended Ground Sensors  

SciTech Connect (OSTI)

In this paper, we have presented the relative advantages and complementary aspects of acoustic and seismic ground sensors. A detailed description of both acoustic and seismic ground sensing methods has been provided. Acoustic and seismic phenomenology including source mechanisms, propagation paths, attenuation, and sensing have been discussed in detail. The effects of seismo-acoustic and acousto-seismic interactions as well as recommendations for minimizing seismic/acoustic cross talk have been highlighted. We have shown representative acoustic and seismic ground sensor data to illustrate the advantages and complementary aspects of the two modalities. The data illustrate that seismic transducers often respond to acoustic excitation through acousto-seismic coupling. Based on these results, we discussed the implications of this phenomenology on the detection, identification, and localization objectives of unattended ground sensors. We have concluded with a methodology for selecting the preferred modality (acoustic and/or seismic) for a particular application.

Elbring, G.J.; Ladd, M.D.; McDonald, T.S.; Sleefe, G.E.

1999-03-31T23:59:59.000Z

357

NLS ground states on graphs  

E-Print Network [OSTI]

We investigate the existence of ground states for the subcritical NLS energy on metric graphs. In particular, we find out a topological assumption that guarantees the nonexistence of ground states, and give an example in which the assumption is not fulfilled and ground states actually exist. In order to obtain the result, we introduce a new rearrangement technique, adapted to the graph where it applies. Owing to such a technique, the energy level of the rearranged function is improved by conveniently mixing the symmetric and monotone rearrangement procedures.

Riccardo Adami; Enrico Serra; Paolo Tilli

2014-06-16T23:59:59.000Z

358

Environmental assessment of ground-water compliance activities at the Uranium Mill Tailings Site, Spook, Wyoming  

SciTech Connect (OSTI)

This report assesses the environmental impacts of the Uranium Mill Tailings Site at Spook, Wyoming on ground water. DOE previously characterized the site and monitoring data were collected during the surface remediation. The ground water compliance strategy is to perform no further remediation at the site since the ground water in the aquifer is neither a current nor potential source of drinking water. Under the no-action alternative, certain regulatory requirements would not be met.

NONE

1997-02-01T23:59:59.000Z

359

Ground Penetrating Radar, Barrow, Alaska  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

This is 500 MHz Ground Penetrating Radar collected along the AB Line in Intensive Site 1 beginning in October 2012 and collected along L2 in Intensive Site 0 beginning in September 2011. Both continue to the present.

John Peterson

360

Ground Water Management Regulations (Louisiana)  

Broader source: Energy.gov [DOE]

The rules and regulations apply to the management of the state's ground water resources. In addition, the Commissioner of Conservation has recommended that oil and gas operators with an interest...

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Calibrating Pesticide Application Ground Equipment  

E-Print Network [OSTI]

This pocket-sized guide gives step-by-step instructions for calibrating ground sprayers. Tables provide instructions, examples and sample formulas for determining speed of application, flow rate and the amount of pesticide to add to the tank....

Shaw, Bryan W.

2000-07-05T23:59:59.000Z

362

Characterizing Hydraulic Properties and Ground-Water Chemistry in Fractured-Rock Aquifers: A User's Manual  

E-Print Network [OSTI]

Characterizing Hydraulic Properties and Ground-Water Chemistry in Fractured-Rock Aquifers: A User source for science about the Earth, its natural and living resources, natural hazards., 2007, Characterizing hydraulic properties and ground-water chemistry in fractured-rock aquifers: A user

363

Sensitivity of the Earthquake Response of Tall Steel Moment Frame Buildings to Ground Motion Features  

E-Print Network [OSTI]

the skyline of many cities in the western US exposed to serious seismicity from a variety of sources. Consider with a simple energy balance analysis. The collapse initiation regime expands to lower ground motion periods are the ground motion features that could collapse these massive structures. Real-world data that could provide

Krishnan, Swaminathan

364

Questa Baseline and Pre-Mining Ground-Water Quality Investigation. 3. Historical Ground-Water  

E-Print Network [OSTI]

............................................................................................................................................................... 9 Mine history and ground-water development ....................................................................................................................................................... 11 Ground-water quality database.......................................................................................................................................................... 29 Compilation of complete database

365

A Simplified Procedure for Sizing Vertical Ground Coupled Heat Pump Heat Exchangers for Residences in Texas  

E-Print Network [OSTI]

the simplified method were compared to two available heat exchanger sizing methods: the National Water Well Association (NWWA) and the International Ground Source Heat Pump Association (IGSHPA). The simplified method predicted shorter lengths than those from...

O'Neal, D. L.; Gonzalez, J. A.; Aldred, W.

1994-01-01T23:59:59.000Z

366

A simplified methodology for sizing ground coupled heat pump heat exchangers in cooling dominated climates  

E-Print Network [OSTI]

between GSIM and two commercially available heat exchanger sizing methods, the National Water Well Association (NWWA) and the International Ground Source Heat Pump Association (IGSHPA) methods, was performed. GSIM heat exchanger lengths for Dallas were... Pump Capacity and Cooling Load. . . . . Oversizing and Undersizing the Heat Pump. . . . . . . . . . . . . . Summary. . 72 74 76 78 80 82 85 87 90 92 IX COMPARISON OF HEAT EXCHANGER SIZING METHODS . . 93 International Ground Source Heat...

Gonzalez, Jose Antonio

1993-01-01T23:59:59.000Z

367

Wide band stepped frequency ground penetrating radar  

DOE Patents [OSTI]

A wide band ground penetrating radar system (10) embodying a method wherein a series of radio frequency signals (60) is produced by a single radio frequency source (16) and provided to a transmit antenna (26) for transmission to a target (54) and reflection therefrom to a receive antenna (28). A phase modulator (18) modulates those portion of the radio frequency signals (62) to be transmitted and the reflected modulated signal (62) is combined in a mixer (34) with the original radio frequency signal (60) to produce a resultant signal (53) which is demodulated to produce a series of direct current voltage signals (66) the envelope of which forms a cosine wave shaped plot (68) which is processed by a Fast Fourier Transform unit 44 into frequency domain data (70) wherein the position of a preponderant frequency is indicative of distance to the target (54) and magnitude is indicative of the signature of the target (54).

Bashforth, Michael B. (Buellton, CA); Gardner, Duane (Santa Maria, CA); Patrick, Douglas (Santa Maria, CA); Lewallen, Tricia A. (Ventura, CA); Nammath, Sharyn R. (Santa Barbara, CA); Painter, Kelly D. (Goleta, CA); Vadnais, Kenneth G. (Alexandria, VA)

1996-01-01T23:59:59.000Z

368

Nonlinear Dynamics of Longitudinal Ground Vehicle Traction  

E-Print Network [OSTI]

asphalt b) Wet asphalt c) Gravel d) Packed Snow Nonlinear Dynamics of Longitudinal Ground Vehicle Traction

Shaw, Steven W.

369

Hanford Site ground-water monitoring for 1993  

SciTech Connect (OSTI)

This report presents the results of the Ground-Water Surveillance Project monitoring for calendar year 1993 on the Hanford Site, Washington. Hanford Site operations from 1943 onward produced large quantities of radiological and chemical waste that have impacted ground-water quality on the Site. Monitoring of water levels and ground-water chemistry is performed to track the extent of contamination and trends in contaminant concentrations. The 1993 monitoring was also designed to identify emerging ground-water quality problems. The information obtained is used to verify compliance with applicable environmental regulations and to evaluate remedial actions. Data from other monitoring and characterization programs were incorporated to provide an integrated assessment of Site ground-water quality. Additional characterization of the Site`s geologic setting and hydrology was performed to support the interpretation of contaminant distributions. Numerical modeling of sitewide ground-water flow also supported the overall project goals. Water-level monitoring was performed to evaluate ground-water flow directions, to track changes in water levels, and to relate such changes to changes in site disposal practices. Water levels over most of the Hanford Site continued to decline between June 1992 and June 1993. The greatest declines occurred in the 200-West Area. These declines are part of the continued response to the cessation of discharge to U Pond and other disposal facilities. The low permeability in this area which enhanced mounding of waste-water discharge has also slowed the response to the reduction of disposal. Water levels remained nearly constant in the vicinity of B Pond, as a result of continued disposal to the pond. Water levels measured from wells in the unconfined aquifer north and east of the Columbia River indicate that the primary source of recharge is irrigation practices.

Dresel, P.E.; Luttrell, S.P.; Evans, J.C. [and others

1994-09-01T23:59:59.000Z

370

Daylight metrics and energy savings  

E-Print Network [OSTI]

Mardaljevic and A. Nabil. Electrochromic glazing and facadeoptimiza- tion of electrochromic operations for occupantmodulating materials (e.g. electrochromic glazing), blinds,

Mardaljevic, John

2011-01-01T23:59:59.000Z

371

DAYLIGHTING DIRECTORY 1/1980  

E-Print Network [OSTI]

of computerized energy trade off studies of AVAILABILITYDES IG:-1 ~1ETHODS 2. Energy trade off analysis of north

,

2012-01-01T23:59:59.000Z

372

DAYLIGHTING DIRECTORY 1/1980  

E-Print Network [OSTI]

PRESENTATIONS ' ~solar Radiation Data, Natural Lighting, andJUROVICS, S.A. "Solar Radiation Data, Natural Lighting, and

,

2012-01-01T23:59:59.000Z

373

Daylight metrics and energy savings  

E-Print Network [OSTI]

with various ‘performance indicators’ becomes ever moreextent that such performance indicators are crude, or the

Mardaljevic, John

2011-01-01T23:59:59.000Z

374

Daylight metrics and energy savings  

E-Print Network [OSTI]

towards sustainable, low-energy buildings has increased thetowards sustainable, low-energy buildings places increasing

Mardaljevic, John

2011-01-01T23:59:59.000Z

375

Natural Daylighting - An Energy Analysis  

E-Print Network [OSTI]

in the final design, as a percentage of the building enclosure within a typical 25 foot wide office bay, is approximately 39 percent. The glass on the north and south elevations is shaded by a brick spandrel which projects 18 inches. East-west facing... glass is shaded by a 15 inch brick spandrel. Projecting brick col umns he1 p to shade the glass with north-south pro- jections of 20 inches and east-west pro- jections of 34 inches. The glazing selected is a one-inch insulated, bronze tinted glass...

Jarrell, R. P.

1987-01-01T23:59:59.000Z

376

daylight | OpenEI Community  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating SolarElectric Coop,SaveWhiskey Flats GeothermalElectric Coop Home7databus

377

OpenEI Community - daylight  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth'sOklahoma/Geothermal < Oklahomast, 2012Coast

378

Nanolens Window Coatings for Daylighting  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l L d F S i DOEToward aInnovationHydrogenNRGA C T Sof

379

Montana Ground Water Assessment Act (Montana)  

Broader source: Energy.gov [DOE]

This statute establishes a program to systematically assess and monitor the state's ground water and to disseminate the information to interested persons in order to improve the quality of ground...

380

Case Study/ Ground Water Sustainability: Methodology and  

E-Print Network [OSTI]

, or the lack thereof, of ground water flow systems driven by similar hydrogeologic and economic conditionsCase Study/ Ground Water Sustainability: Methodology and Application to the North China Plain of a ground water flow system in the North China Plain (NCP) subject to severe overexploitation and rapid

Zheng, Chunmiao

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

CARD No. 53 Consideration of Underground Sources of Drinking Water  

E-Print Network [OSTI]

exposure of individuals and the possible levels of radioactive contamination of ground water due resulting from exposure to radioactive contaminants in underground sources of drinking water (USDWs.34, which implement the general containment requirements of the radioactive waste disposal regulations

382

Infrared source test  

SciTech Connect (OSTI)

The purpose of the Infrared Source Test (IRST) is to demonstrate the ability to track a ground target with an infrared sensor from an airplane. The system is being developed within the Advance Technology Program`s Theater Missile Defense/Unmanned Aerial Vehicle (UAV) section. The IRST payload consists of an Amber Radiance 1 infrared camera system, a computer, a gimbaled mirror, and a hard disk. The processor is a custom R3000 CPU board made by Risq Modular Systems, Inc. for LLNL. The board has ethernet, SCSI, parallel I/O, and serial ports, a DMA channel, a video (frame buffer) interface, and eight MBytes of main memory. The real-time operating system VxWorks has been ported to the processor. The application code is written in C on a host SUN 4 UNIX workstation. The IRST is the result of a combined effort by physicists, electrical and mechanical engineers, and computer scientists.

Ott, L.

1994-11-15T23:59:59.000Z

383

Atlas SCT/Pixel Grounding and Shielding ATLAS SCT/Pixel Grounding and Shielding Note  

E-Print Network [OSTI]

Atlas SCT/Pixel Grounding and Shielding 1 ATLAS SCT/Pixel Grounding and Shielding Note November 22 mostly connects existing mechanical electrical conductive #12; Atlas SCT/Pixel Grounding and Shielding 2 that equivalent. The barrel outer heat shield (150 aluminum) main element shield. #12; Atlas SCT/Pixel Grounding

California at Santa Cruz, University of

384

TEX-A-SYST: Reducing the Risk of Ground Water Contamination by Improving Livestock Holding Pen Management  

E-Print Network [OSTI]

Open lots or holding pens for feeding or holding livestock can be sources of ground water contamination. The safety of such operations depends on their separation from water wells, characteristics of the site, and proper management. This publication...

Harris, Bill L.; Hoffman, D.; Mazac Jr., F. J.

1997-08-29T23:59:59.000Z

385

TEX-A-SYST: Reducing the Risk of Ground Water Contamination by Improving Fertilizer Storage and Handling  

E-Print Network [OSTI]

Fertilizer is a major source of ground water contamination. This publication emphasizes the best management practices for storing fertilizers, whether you are building a new facility or modifying an existing one. It also includes information on safe...

Harris, Bill L.; Hoffman, D.; Mazac Jr., F. J.; Kantor, A. S.

1997-08-29T23:59:59.000Z

386

Ground Penetrating Radar in Hydrogeophysics  

SciTech Connect (OSTI)

To meet the needs of a growing population and to provide us with a higher quality of life, increasing pressures are being placed on our environment through the development of agriculture, industry, and infrastructures. Soil erosion, groundwater depletion, salinization, and pollution have been recognized for decades as major threats to ecosystems and human health. More recently, the progressive substitution of fossil fuels by biofuels for energy production and climate change have been recognized as potential threats to our water resources and sustained agricultural productivity. The vadose zone mediates many of the processes that govern water resources and quality, such as the partition of precipitation into infiltration and runoff , groundwater recharge, contaminant transport, plant growth, evaporation, and energy exchanges between the Earth's surface and its atmosphere. It also determines soil organic carbon sequestration and carbon-cycle feedbacks, which could substantially impact climate change. The vadose zone's inherent spatial variability and inaccessibility precludes direct observation of the important subsurface processes. In a societal context where the development of sustainable and optimal environmental management strategies has become a priority, there is a strong prerequisite for the development of noninvasive characterization and monitoring techniques of the vadose zone. In particular, hydrogeophysical approaches applied at relevant scales are required to appraise dynamic subsurface phenomena and to develop optimal sustainability, exploitation, and remediation strategies. Among existing geophysical techniques, ground penetrating radar (GPR) technology is of particular interest for providing high-resolution subsurface images and specifically addressing water-related questions. Ground penetrating radar is based on the transmission and reception of VHF-UHF (30-3000 MHz) electromagnetic waves into the ground, whose propagation is determined by the soil electromagnetic properties and their spatial distribution. As the dielectric permittivity of water overwhelms the permittivity of other soil components, the presence of water in the soil principally governs GPR wave propagation. Therefore, GPR-derived dielectric permittivity is usually used as surrogate measure for soil water content. In the areas of unsaturated zone hydrology and water resources, GPR has been used to identify soil stratigraphy, to locate water tables, to follow wetting front movement, to estimate soil water content, to assist in subsurface hydraulic parameter identification, to assess soil salinity, and to support the monitoring of contaminants. The purpose of this special section of the Vadose Zone Journal is to present recent research advances and applications of GPR in hydrogeophysics, with a particular emphasis on vadose zone investigations. This special section includes contributions presented at the European Geosciences Union General Assembly 2006 (EGU 2006, Vienna, Austria) and the 11th International Conference on Ground Penetrating Radar (GPR 2006, Columbus, OH). The studies presented here deal with a wide range of surface and borehole GPR applications, including GPR sensitivity to contaminant plumes, new methods for soil water content determination, three-dimensional imaging of the subsurface, time-lapse monitoring of hydrodynamic events and inversion techniques for soil hydraulic properties estimation, and joint interpretation of GPR and electric resistivity tomography (ERT) data.

Hubbard, Susan; Lambot, S.; Binley, A.; Slob, E.; Hubbard, S.

2008-01-15T23:59:59.000Z

387

Interim site characterization report and ground-water monitoring program for the Hanford site solid waste landfill  

SciTech Connect (OSTI)

Federal and state regulations governing the operation of landfills require utilization of ground-water monitoring systems to determine whether or not landfill operations impact ground water at the point of compliance (ground water beneath the perimeter of the facility). A detection-level ground-water monitoring system was designed, installed, and initiated at the Hanford Site Solid Waste Landfill (SWL). Chlorinated hydrocarbons were detected at the beginning of the ground-water monitoring program and continue to be detected more than 1 year later. The most probable source of the chlorinated hydrocarbons is washwater discharged to the SWL between 1985 and 1987. This is an interim report and includes data from the characterization work that was performed during well installation in 1987, such as field observations, sediment studies, and geophysical logging results, and data from analyses of ground-water samples collected in 1987 and 1988, such as field parameter measurements and chemical analyses. 38 refs., 27 figs., 8 tabs.

Fruland, R.M.; Hagan, R.A.; Cline, C.S.; Bates, D.J.; Evans, J.C.; Aaberg, R.L.

1989-07-01T23:59:59.000Z

388

Evaluation of analytical methods to interpret ground deformations due to soft ground tunneling  

E-Print Network [OSTI]

An in depth study was undertaken to evaluate the effectiveness of analytical solutions in describing ground movements induced by soft ground tunneling. The analytical solutions that were examined consider both isotropic ...

Zymnis, Despina M

2009-01-01T23:59:59.000Z

389

Special Section on Ground Water Research in China Featured in This Issue of Ground Water  

E-Print Network [OSTI]

of Ground Water by Xun Zhou1, Jiu J. Jiao2, and Mary P. Anderson3 Contained in this issue of Ground Water, Groundwater Resources and the Related Environ- Hydrogeologic Problems in China, Beijing: Seismological Press

Jiao, Jiu Jimmy

390

Source Four Ellipsoidal Series  

E-Print Network [OSTI]

parallel-blade U-ground connector -B two-pin and ground, 20 amp connector -c grounded, 20 amp, twistlock. to convert data when using any other HpL lamp, use the lumen or candela multiplying factors (Lm mf or cd mf) for that specific lamp, listed in the Lamps table in this datasheet. for lumen data, multiply by the Lm mf

Martin, Jeff

391

International Borders, Ground Water Flow, and Hydroschizophrenia  

E-Print Network [OSTI]

beginning to be recognized. The hidden nature of ground water and the lack of international law governingInternational Borders, Ground Water Flow, and Hydroschizophrenia by Todd Jarvis1,2, Mark Giordano3 conducted on transboundary water, transboundary water law, and the mitigation of transboundary water

Wolf, Aaron

392

Rotor Blades and Ground Effect Richard Purvis  

E-Print Network [OSTI]

Rotor Blades and Ground Effect Richard Purvis Department of Mathematics University College London to examine various aspects of rotor blade flows and ground effect. It explores two- and three- dimensional flows, generally concentrating upon regimes that have a degree of rel- evance to typical rotor blade

Purvis, Richard

393

Ground Turkey and Potato Plate Ingredients  

E-Print Network [OSTI]

Ground Turkey and Potato Plate Ingredients: 1 onion 1/2 pound ground turkey 1 cup ketchup, low sodium 4 medium potatoes 4 ounces cheddar cheese, low-fat Directions 1. Cut the ends off of the onion. Meanwhile pierce potatoes in several places with fork. Place on baking dish in microwave oven. Microwave

Liskiewicz, Maciej

394

Ground water provides drinking water, irrigation for  

E-Print Network [OSTI]

Ground water provides drinking water, irrigation for crops and water for indus- tries. It is also connected to surface waters, and maintains the flow of rivers and streams and the level of wetlands- tion of those along Lake Michigan, most communi- ties, farms and industries still rely on ground water

Saldin, Dilano

395

Radiation source  

DOE Patents [OSTI]

A device and method for relativistic electron beam heating of a high-density plasma in a small localized region. A relativistic electron beam generator or accelerator produces a high-voltage electron beam which propagates along a vacuum drift tube and is modulated to initiate electron bunching within the beam. The beam is then directed through a low-density gas chamber which provides isolation between the vacuum modulator and the relativistic electron beam target. The relativistic beam is then applied to a high-density target plasma which typically comprises DT, DD, or similar thermonuclear gas at a density of 10.sup.17 to 10.sup.20 electrons per cubic centimeter. The target gas is ionized prior to application of the relativistic electron beam by means of a laser or other preionization source to form a plasma. Utilizing a relativistic electron beam with an individual particle energy exceeding 3 MeV, classical scattering by relativistic electrons passing through isolation foils is negligible. As a result, relativistic streaming instabilities are initiated within the high-density target plasma causing the relativistic electron beam to efficiently deposit its energy into a small localized region of the high-density plasma target.

Thode, Lester E. (Los Alamos, NM)

1981-01-01T23:59:59.000Z

396

GROUND-COUPLED HEAT-PUMP-SYSTEM EXPERIMENTAL RESULTS* Philip D. Metz  

E-Print Network [OSTI]

#12;GROUND-COUPLED HEAT-PUMP-SYSTEM EXPERIMENTAL RESULTS* Philip D. Metz _Solar and Renewables house in Upton, Long Island, New York has been heated and cooled by a liquid source heat pump using- saving construction with a heating load of 7.8 X 106 J/OC-day (4.1 X 103 Btu/ OF-day). The heat pump used

Oak Ridge National Laboratory

397

HOME GROUNDS & ANIMALS 2014 Home Fruit: Disease and Insects 3-1  

E-Print Network [OSTI]

HOME GROUNDS & ANIMALS 2014 Home Fruit: Disease and Insects 3-1 Disease and Insects Keith S. Yoder Pathologist, Alson H. Smith Jr. AREC Overview Growing fruits in the home orchard or garden can be an interesting and satisfying hobby, as well as a source of nutritious food for the home gardener. Tree fruits

Liskiewicz, Maciej

398

Vertical Concentric Tube Ground Couoled Heat Exchangers V. C. Mei and S. K. Fischer*  

E-Print Network [OSTI]

to extract heat from or reject heat to the environment. The majority of heat pumps use ambient air of the air. Ground water is a better heat source/sink for heat pump application (due to its superior thermal exchangers for use in heat-pump applications is described. The experimental apparatus consists

Oak Ridge National Laboratory

399

Importance of moisture transport, snow cover and soil freezing to ground temperature predictions  

E-Print Network [OSTI]

foundation may also be explicitly calculated. For buildings utilizing ground source heat pump systems of the annual outdoor and indoor air temperatures. Then periodic heat transfer coefficients and phase lags with significant earth contact. A numerical model for heat and moisture transfer in partially frozen soils has been

400

First conference on ground control problems in the Illinois Coal Basin: proceedings  

SciTech Connect (OSTI)

The first conference on ground control problems in the Illinois Coal Basin was held at the Southern Illinois University at Carbondale, Illinois, August 22-24, 1979. Twenty-one papers from the proceedings have been entered individually into EDB; one had been entered previously from other sources. (LTN)

Chugh, Y.P.; Van Besien, A. (eds.)

1980-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Scaling Considerations in Ground State Quantum Computation  

E-Print Network [OSTI]

We study design challenges associated with realizing a ground state quantum computer. In such a computer, the energy gap between the ground state and first excited state must be sufficiently large to prevent disruptive excitations. Here, an estimate is provided of this gap as a function of computer size. We then address the problem of detecting the output of a ground state quantum computer. It is shown that the exponential detection difficulties that appear to be present at first can be overcome in a straightforward manner by small design changes.

Ari Mizel; M. W. Mitchell; Marvin L. Cohen

2000-07-02T23:59:59.000Z

403

A note on classical ground state energies  

E-Print Network [OSTI]

The pair-specific ground state energy of Newtonian N-body systems grows monotonically in N. This furnishes a whole family of simple new tests for minimality of putative ground state energies obtained through computer experiments. Inspection of several publically available lists of such computer-experimentally obtained putative ground state energies has yielded several dozen instances which failed (at least) one of these tests. Although the correct ground state energy is not revealed by this method, it does yield a better upper bound on it than the experimentally found value whenever the latter fails a monotonicity test. The surveyed N-body systems include in particular N point charges with 2- or 3-dimensional Coulomb pair interactions, placed either on the unit 2-sphere or on a 2-torus (a.k.a. Thomson, Fekete, or Riesz problems).

Michael K. -H. Kiessling

2009-05-28T23:59:59.000Z

404

Commonality of ground systems in launch operations  

E-Print Network [OSTI]

NASA is examining the utility of requiring a certain degree of commonality in both flight and ground systems in the Constellation Program. While the benefits of commonality seem obvious in terms of minimizing upfront ...

Quinn, Shawn M

2008-01-01T23:59:59.000Z

405

Ground Water Protection Act (New Mexico)  

Broader source: Energy.gov [DOE]

The purpose of the Ground Water Protection Act is to provide substantive provisions and funding mechanisms to the extent that funds are available to enable the state to take corrective action at...

406

Building an entanglement measure on physical ground  

E-Print Network [OSTI]

We introduce on physical grounds a new measure of multipartite entanglement for pure states. The function we define is discriminant and monotone under LOCC and moreover can be expressed in terms of observables of the system.

D. Teresi; A. Napoli; A. Messina

2008-05-28T23:59:59.000Z

407

Shielding and grounding in large detectors  

SciTech Connect (OSTI)

Prevention of electromagnetic interference (EMI), or ``noise pickup,`` is an important design aspect in large detectors in accelerator environments. Shielding effectiveness as a function of shield thickness and conductivity vs the type and frequency of the interference field is described. Noise induced in transmission lines by ground loop driven currents in the shield is evaluated and the importance of low shield resistance is emphasized. Some measures for prevention of ground loops and isolation of detector-readout systems are discussed.

Radeka, V.

1998-09-01T23:59:59.000Z

408

A THERMIE PROGRAMME ACTION THERMIE Daylighting in Buildings The European Commission Directorate-General for Energy (DGXVII) R.E. The THERMIE Programme  

E-Print Network [OSTI]

This is an important European Community instrument. It is designed to promote greater use of European energy technologies. THERMIE is a major EC initiative, it will run for five years (1990-94) and it is estimated that the EC contribution during this period will amount to 700 million ECU. The main aims of THERMIE are to: · promote innovative energy technologies; · disseminate information on these technologies; · encourage greater use of new and renewable energy sources; · improve energy efficiency; · improve environmental protection. THERMIE has been developed from previous EC programmes and provides enhanced provision for:

unknown authors

409

Ground water protection management program plan  

SciTech Connect (OSTI)

U.S. Department of Energy (DOE) Order 5400.1 requires the establishment of a ground water protection management program to ensure compliance with DOE requirements and applicable federal, state, and local laws and regulations. The Uranium Mill Tailings Remedial Action (UMTRA) Project Office was prepared this Ground Water Protection Management Program Plan (ground water protection plan) whose scope and detail reflect the program`s significance and address the seven activities required in DOE Order 5400.1, Chapter III, for special program planning. This ground water protection plan highlights the methods designed to preserve, protect, and monitor ground water resources at UMTRA Project processing and disposal sites. The plan includes an overview of the remedial action status at the 24 designated processing sites and identifies technical guidance documents and site-specific documents for the UMTRA Project ground water protection management program. In addition, the plan addresses the general information required to develop a water resources protection strategy at the permanent disposal sites. Finally, the plan describes ongoing activities that are in various stages of development at UMTRA Project sites.

Not Available

1994-02-01T23:59:59.000Z

410

Journal of Educational Psychology Applying Grounded Coordination Challenges to Concrete  

E-Print Network [OSTI]

Journal of Educational Psychology Applying Grounded Coordination Challenges to Concrete Learning, M. I. (2013, August 19). Applying Grounded Coordination Challenges to Concrete Learning Materials.1037/a0034098 #12;Applying Grounded Coordination Challenges to Concrete Learning Materials: A Study

411

Source Four Ellipsoidal Series  

E-Print Network [OSTI]

Parallel-blade U-ground connector -B Two-pin and ground, 20 amp connector -C grounded, 20 amp, twistlock lamp, use the lumen or candela multiplying factors (Lm mF or Cd mF) for that specific lamp, listed in the Lamps table in this datasheet. For lumen data, multiply by the Lm mF. For candela or footcandle data

Martin, Jeff

412

Extreme-UV electrical discharge source  

DOE Patents [OSTI]

An extreme ultraviolet and soft x-ray radiation electric capillary discharge source that includes a boron nitride housing defining a capillary bore that is positioned between two electrodes one of which is connected to a source of electric potential can generate a high EUV and soft x-ray radiation flux from the capillary bore outlet with minimal debris. The electrode that is positioned adjacent the capillary bore outlet is typically grounded. Pyrolytic boron nitride, highly oriented pyrolytic boron nitride, and cubic boron nitride are particularly suited. The boron nitride capillary bore can be configured as an insert that is encased in an exterior housing that is constructed of a thermally conductive material. Positioning the ground electrode sufficiently close to the capillary bore outlet also reduces bore erosion.

Fornaciari, Neal R. (Tracey, CA); Nygren, Richard E. (Los Ranchos de Albuquerque, NM); Ulrickson, Michael A. (Albuquerque, NM)

2002-01-01T23:59:59.000Z

413

GROUND PLANE INSULATION FAILURE IN THE FIRST TPC SUPERCONDUCTING COIL  

E-Print Network [OSTI]

is WIUUTEO GROUND PLANE INSULATION FAILURE IN THE FIRST TPCOn August 27, 1980, an insulation failure occurred dt-ringby a failure uf ground plane insulation. ACKNOWLEDGMENTS The

Green, M.A.

2010-01-01T23:59:59.000Z

414

Department of Veterans Affairs, FONSI - Ground mounted solar...  

Broader source: Energy.gov (indexed) [DOE]

Ground mounted solar photovoltaic power at San Joaquin National Cemetery Department of Veterans Affairs, FONSI - Ground mounted solar photovoltaic power at San Joaquin National...

415

China's Evolving Defense Economy: A PLA Ground Force Perspective  

E-Print Network [OSTI]

s Evolving Defense Economy: A PLA Ground Force PerspectivePeople’s Liberation Army (PLA) doctrinal developments,modernization of the PLA ground forces have incrementally

COOPER, Cortez A.

2013-01-01T23:59:59.000Z

416

A model of ATL ground motion for storage rings  

E-Print Network [OSTI]

A MODEL OF ATL GROUND MOTION FOR STORAGE RINGS A. WolskiMODEL OF ATL GROUND MOTION FOR STORAGE RINGS* A. Wolski # ,

Wolski, Andrzej; Walker, Nicholas J.

2003-01-01T23:59:59.000Z

417

Water on Earth Source % of Supply  

E-Print Network [OSTI]

1 Water on Earth Source % of Supply Oceans 97.08 Ice Sheets and Glaciers 1.99 Ground Water 0.62 Atmosphere 0.29 Lakes (Fresh) 0.01 Inland Seas / Salt Water Lakes 0.005 Soil Moisture 0.004 Rivers 0.001 Water · Water is the solvent, the medium and the participant in most of the chemical reactions occurring

Cochran-Stafira, D. Liane

418

Rock magnetic investigation of possible sources of the Bangui magnetic anomaly1 , M., Quesnel2*  

E-Print Network [OSTI]

Rock magnetic investigation of possible sources of the Bangui magnetic anomaly1 2 Ouabego1,2 , M slices of such28 metamorphic rocks, or by an iron-rich mafic source, or by a combination of these two29 source using constraints19 from satellite and ground magnetic field measurements, as well as from surface

Boyer, Edmond

419

Longevity of Emplacement Drift Ground Support Materials  

SciTech Connect (OSTI)

The purpose of this analysis is to evaluate the factors affecting the longevity of emplacement drift ground support materials and to develop a basis for selection of materials for ground support that will function throughout the preclosure period. The Development Plan (DP) for this analysis is given in CRWMS M&O (Civilian Radioactive Waste Management System Management and Operating Contractor) (1999a). The candidate materials for ground support are steel (carbon steel, ductile cast iron, galvanized steel, and stainless steel, etc.) and cement. Steel will mainly be used for steel sets, lagging, channels, rock bolts, and wire mesh. Cement usage is only considered in the case of grouted rock bolts. The candidate materials for the invert structure are steel and crushed rock ballast. The materials shall be evaluated for the repository emplacement drift environment under a specific thermal loading condition based on the proposed License Application Design Selection (LADS) design. The analysis consists of the following tasks: (1) Identify factors affecting the longevity of ground control materials for use in emplacement drifts. (2) Review existing documents concerning behavior of candidate ground control materials during the preclosure period. The major criteria to be considered for steel are mechanical and thermal properties, and durability, of which corrosion is the most important concern. (3) Evaluate the available results and develop recommendations for material(s) to be used.

D. Tang

2000-01-07T23:59:59.000Z

420

Portable Source Identification Device  

SciTech Connect (OSTI)

U.S. Customs and Border Protection (CBP) is the primary enforcement agency protecting the nation’s ports of entry. CBP is enhancing its capability to interdict the illicit import of nuclear and radiological materials and devices that may be used by terrorists. Pacific Northwest National Laboratory (PNNL) is providing scientific and technical support to CBP in their goal to enable rapid deployment of nuclear and radiation detection systems at U. S. ports of entry to monitor 100% of the incoming international traffic and cargo while not adversely impacting the operations or throughput of the ports. As the deployment of radiation detection systems proceeds, there is a need to adapt the baseline radiation portal monitor (RPM) system technology to operations at these diverse ports of entry. When screening produces an alarm in the primary inspection RPM, the alarming vehicle is removed from the flow of commerce and the alarm is typically confirmed in a secondary inspection RPM. The portable source identification device (PSID) is a radiation sensor panel (RSP), based on thallium-doped sodium iodide (NaI(Tl)) scintillation detector and gamma spectroscopic analysis hardware and software, mounted on a scissor lift on a small truck. The lift supports a box containing a commercial off-the-shelf (COTS) sodium iodide detector that provides real-time isotopic identification, including neutron detectors to interdict Weapons of Mass Destruction (WMD) and radiation dispersion devices (RDD). The scissor lift will lower the detectors to within a foot off the ground and raise them to approximately 24 feet in the air, allowing a wide vertical scanning range.

Andersen, Eric S.; Samuel, Todd J.; Gervais, Kevin L.

2005-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Mimicking Time Evolution within a Quantum Ground State: Ground-State Quantum Computation, Cloning, and Teleportation  

E-Print Network [OSTI]

Ground-state quantum computers mimic quantum mechanical time evolution within the amplitudes of a time-independent quantum state. We explore the principles that constrain this mimicking. A no-cloning argument is found to impose strong restrictions. It is shown, however, that there is flexibility that can be exploited using quantum teleportation methods to improve ground-state quantum computer design.

Ari Mizel

2003-12-09T23:59:59.000Z

422

The ground state energy at unitarity  

E-Print Network [OSTI]

We consider two-component fermions on the lattice in the unitarity limit. This is an idealized limit of attractive fermions where the range of the interaction is zero and the scattering length is infinite. Using Euclidean time projection, we compute the ground state energy using four computationally different but physically identical auxiliary-field methods. The best performance is obtained using a bounded continuous auxiliary field and a non-local updating algorithm called hybrid Monte Carlo. With this method we calculate results for 10 and 14 fermions at lattice volumes 4^3, 5^3, 6^3, 7^3, 8^3 and extrapolate to the continuum limit. For 10 fermions in a periodic cube, the ground state energy is 0.292(12) times the ground state energy for non-interacting fermions. For 14 fermions the ratio is 0.329(5).

Dean Lee

2008-07-28T23:59:59.000Z

423

Detection of 6 November 1997 Ground Level Event by Milagrito  

E-Print Network [OSTI]

Solar Energetic Particles from the 6 November 1997 solar flare/CME(coronal mass ejection) with energies exceeding 10 GeV have been detected by Milagrito, a prototype of the Milagro Gamma Ray Observatory. While particle acceleration beyond 1 GeV at the Sun is well established, few data exist for protons or ions beyond 10 GeV. The Milagro observatory, a ground based water Cherenkov detector designed for observing very high energy gamma ray sources, can also be used to study the Sun. Milagrito, which operated for approximately one year in 1997/98, was sensitive to solar proton and neutron fluxes above ~5- 10 GeV. Milagrito operated in a scaler mode, which was primarily sensitive to muons, low energy photons, and electrons, and the detector operated in a mode sensitive to showers and high zenith angle muons. In its scaler mode, Milagrito registered a rate increase coincident with the 6 November 1997 ground level event observed by Climax and other neutron monitors. A preliminary analysis suggests the presence of >...

Atkins, R; Berley, D; Chen, M L; Coyne, D G; Delay, R S; Dingus, B L; Dorfan, D E; Ellsworth, R W; Evans, D; Falcone, A D; Fleysher, L; Fleysher, R; Gisler, G; Goodman, J A; Haines, T J; Hoffman, C M; Hugenberger, S; Kelley, L A; Leonor, I; Macri, J R; McConnell, M; McCullough, J F; McEnery, J E; Miller, R S; Mincer, A I; Morales, M F; Némethy, P; Ryan, J M; Schneider, M; Shen, B; Shoup, A L; Sinnis, G; Smith, A J; Sullivan, G W; Thompson, T N; Tümer, T O; Wang, K; Wascko, M O; Westerhoff, S; Williams, D A; Yang, T; Yodh, G B

1999-01-01T23:59:59.000Z

424

Detection of 6 November 1997 Ground Level Event by Milagrito  

E-Print Network [OSTI]

Solar Energetic Particles from the 6 November 1997 solar flare/CME(coronal mass ejection) with energies exceeding 10 GeV have been detected by Milagrito, a prototype of the Milagro Gamma Ray Observatory. While particle acceleration beyond 1 GeV at the Sun is well established, few data exist for protons or ions beyond 10 GeV. The Milagro observatory, a ground based water Cherenkov detector designed for observing very high energy gamma ray sources, can also be used to study the Sun. Milagrito, which operated for approximately one year in 1997/98, was sensitive to solar proton and neutron fluxes above ~5- 10 GeV. Milagrito operated in a scaler mode, which was primarily sensitive to muons, low energy photons, and electrons, and the detector operated in a mode sensitive to showers and high zenith angle muons. In its scaler mode, Milagrito registered a rate increase coincident with the 6 November 1997 ground level event observed by Climax and other neutron monitors. A preliminary analysis suggests the presence of >10 GeV particles.

R. Atkins; W. Benbow; D. Berley; M. -L. Chen; D. G. Coyne; R. S. Delay; B. L. Dingus; D. E. Dorfan; R. W. Ellsworth; D. Evans; A. Falcone; L. Fleysher; R. Fleysher; G. Gisler; J. A. Goodman; T. J. Haines; C. M. Hoffman; S. Hugenberger; L. A. Kelley; I. Leonor; J. Macri; M. McConnell; J. F. McCullough; J. E. McEnery; R. S. Miller; A. I. Mincer; M. F. Morales; P. Nemethy; J. M. Ryan; M. Schneider; B. Shen; A. Shoup; G. Sinnis; A. J. Smith; G. W. Sullivan; T. N. Thompson; O. T. Tumer; K. Wang; M. O. Wascko; S. Westerhoff; D. A. Williams; T. Yang; G. B. Yodh

1999-06-24T23:59:59.000Z

425

Ground Control for Emplacement Drifts for SR  

SciTech Connect (OSTI)

This analysis demonstrates that a satisfactory ground control system can be designed for the Yucca Mountain site, and provides the technical basis for the design of ground support systems to be used in repository emplacement and non-emplacement drifts. The repository ground support design was based on analytical methods using acquired computer codes, and focused on the final support systems. A literature review of case histories, including the lessons learned from the design and construction of the ESF, the studies on the seismic damages of underground openings, and the use of rock mass classification systems in the ground support design, was conducted (Sections 6.3.4 and 6.4). This review provided some basis for determining the inputs and methodologies used in this analysis. Stability of the supported and unsupported emplacement and non-emplacement drifts was evaluated in this analysis. The excavation effects (i.e., state of the stress change due to excavation), thermal effects (i.e., due to heat output from waste packages), and seismic effects (i.e., from potential earthquake events) were evaluated, and stress controlled modes of failure were examined for two in situ stress conditions (k_0=0.3 and 1.0) using rock properties representing rock mass categories of 1 and 5. Variation of rock mass units such as the non-lithophysal (Tptpmn) and lithophysal (Tptpll) was considered in the analysis. The focus was on the non-lithophysal unit because this unit appears to be relatively weaker and has much smaller joint spacing. Therefore, the drift stability and ground support needs were considered to be controlled by the design for this rock unit. The ground support systems for both emplacement and non-emplacement drifts were incorporated into the models to assess their performance under in situ, thermal, and seismic loading conditions. Both continuum and discontinuum modeling approaches were employed in the analyses of the rock mass behavior and in the evaluation of the stability of the openings. No credit or account was given for the initial ground support in modeling the final ground support systems for both emplacement and non-emplacement drifts in this analysis.

Y. Sun

2000-04-07T23:59:59.000Z

426

Sampling Throughout The Hydrologic Cycle To Characterize Sources Of Volatile Organic  

E-Print Network [OSTI]

ether (MTBE) are sufficiently high to cause detection in ground water, whereas atmospheric that point sources of MTBE, such as spills or infiltration of urban runoff, are also prevalent are widespread. MTBE is detected less frequently in observation wells that tap 10- to 15-year-old ground water

Torgersen, Christian

427

Ground-state cooling of a trapped ion using long-wavelength radiation  

E-Print Network [OSTI]

We demonstrate ground-state cooling of a trapped ion using long-wavelength radiation. This is a powerful tool for the implementation of quantum operations, where long-wavelength radiation instead of lasers is used for motional quantum state engineering. We measure a mean phonon number of $\\overline{n} = 0.13(4)$ after sideband cooling, corresponding to a ground-state occupation probability of 88(7)\\%. After preparing in the vibrational Fock state $\\left|n=0\\right\\rangle$, we implement sideband Rabi oscillations which last for more than 10 ms, demonstrating the long coherence time of our system. We also use the ability to ground-state cool to accurately measure the motional heating rate and report a reduction by almost two orders of magnitude compared to our previously measured result, which we attribute to carefully eliminating sources of electrical noise in the system.

Weidt, S; Webster, S C; Standing, E D; Rodriguez, A; Webb, A E; Lekitsch, B; Hensinger, W K

2015-01-01T23:59:59.000Z

428

Ground-state cooling of a trapped ion using long-wavelength radiation  

E-Print Network [OSTI]

We demonstrate ground-state cooling of a trapped ion using long-wavelength radiation. This is a powerful tool for the implementation of quantum operations, where long-wavelength radiation instead of lasers is used for motional quantum state engineering. We measure a mean phonon number of $\\overline{n} = 0.13(4)$ after sideband cooling, corresponding to a ground-state occupation probability of 88(7)\\%. After preparing in the vibrational Fock state $\\left|n=0\\right\\rangle$, we implement sideband Rabi oscillations which last for more than 10 ms, demonstrating the long coherence time of our system. We also use the ability to ground-state cool to accurately measure the motional heating rate and report a reduction by almost two orders of magnitude compared to our previously measured result, which we attribute to carefully eliminating sources of electrical noise in the system.

S. Weidt; J. Randall; S. C. Webster; E. D. Standing; A. Rodriguez; A. E. Webb; B. Lekitsch; W. K. Hensinger

2015-01-07T23:59:59.000Z

429

40 CFR 265 interim-status ground-water monitoring plan for the 2101-M pond  

SciTech Connect (OSTI)

This report outlines a ground-water monitoring plan for the 2101-M pond, located in the southwestern part of the 200-East Area on the Hanford Site in south-central Washington State. It has been determined that hazardous materials may have been discharged to the pond. Installation of an interim-status ground-water monitoring system is required under the Resource Conservation and Recovery Act to determine if hazardous chemicals are moving out of the pond. This plan describes the location of new wells for the monitoring system, how the wells are to be completed, the data to be collected, and how those data can be used to determine the source and extent of any ground-water contamination from the 2101-M pond. Four new wells are planned, one upgradient and three downgradient. 35 refs., 12 figs., 9 tabs.

Chamness, M.A.; Luttrell, S.P.; Dudziak, S.

1989-03-01T23:59:59.000Z

430

Camera calibration and light source orientation from solar shadows Xiaochun Cao *, Hassan Foroosh  

E-Print Network [OSTI]

a method for recovering camera parameters from perspective views of daylight shadows in a scene, given only the solution for the case when the camera intrinsic parameters can vary. Gurdjos et al. [11] formulated

Foroosh, Hassan

431

Selenium in Oklahoma ground water and soil  

SciTech Connect (OSTI)

Selenium with a consumption of 2 liters per day (5). The objectives of this study are: (1) to determine the concentrations of Se in Oklahoma ground water and soil samples. (2) to map the geographical distribution of Se species in Oklahoma. (3) to relate groundwater depth, pH and geology with concentration of Se.

Atalay, A.; Vir Maggon, D.

1991-03-30T23:59:59.000Z

432

Photovoltaic module mounting clip with integral grounding  

DOE Patents [OSTI]

An electrically conductive mounting/grounding clip, usable with a photovoltaic (PV) assembly of the type having an electrically conductive frame, comprises an electrically conductive body. The body has a central portion and first and second spaced-apart arms extending from the central portion. Each arm has first and second outer portions with frame surface-disrupting element at the outer portions.

Lenox, Carl J.

2010-08-24T23:59:59.000Z

433

Above Ground Storage Tank (AST) Inspection Form  

E-Print Network [OSTI]

Above Ground Storage Tank (AST) Inspection Form Petroleum Bulk Storage Form Facility Name: ______________________ Tank No:_______________ Date:_____________ Inspection Parameter Result Comments/Corrective Actions 1. Is there leaking in the interstitial space (not DRY)? YES/NO/NA 2. Tank surface shows signs of leakage? YES/NO/NA 3

Pawlowski, Wojtek

434

Longevity of Emplacement Drift Ground Support Materials  

SciTech Connect (OSTI)

The purpose of this analysis is to evaluate the factors affecting the longevity of emplacement drift ground support materials and to develop a basis for the selection of materials for ground support that will function throughout the preclosure period of a potential repository at Yucca Mountain. REV 01 ICN 01 of this analysis is developed in accordance with AP-3.10Q, Analyses and Models, Revision 2, ICN 4, and prepared in accordance with the Technical Work Plan for Subsurface Design Section FY 01 Work Activities (CRWMS M&O 2001a). The objective of this analysis is to update the previous analysis (CRWMS M&O 2000a) to account for related changes in the Ground Control System Description Document (CRWMS M&O 2000b), the Monitored Geologic Repository Project Description Document, which is included in the Requirements and Criteria for Implementing a Repository Design that can be Operated Over a Range of Thermal Modes (BSC 2001), input information, and in environmental conditions, and to provide updated information on candidate ground support materials. Candidate materials for ground support are carbon steel and cement grout. Steel is mainly used for steel sets, lagging, channel, rock bolts, and wire mesh. Cement grout is only considered in the case of grouted rock bolts. Candidate materials for the emplacement drift invert are carbon steel and granular natural material. Materials are evaluated for the repository emplacement drift environment based on the updated thermal loading condition and waste package design. The analysis consists of the following tasks: (1) Identify factors affecting the longevity of ground support materials for use in emplacement drifts. (2) Review existing documents concerning the behavior of candidate ground support materials during the preclosure period. (3) Evaluate impacts of temperature and radiation effects on mechanical and thermal properties of steel. Assess corrosion potential of steel at emplacement drift environment. (4) Evaluate factors affecting longevity of cement grouts for fully grouted rock bolt system. Provide updated information on cement grout mix design for fully grouted rock bolt system. (5) Evaluate longevity of materials for the emplacement drift invert.

D.H.Tang

2001-05-30T23:59:59.000Z

435

Electrolytes for power sources  

DOE Patents [OSTI]

Electrolytes are disclosed for power sources, particularly alkaline and acidic power sources, comprising benzene polysulfonic acids and benzene polyphosphonic acids or salts of such acids. 7 figures.

Doddapaneni, N.; Ingersoll, D.

1995-01-03T23:59:59.000Z

436

Protected Water Sources (Iowa)  

Broader source: Energy.gov [DOE]

This chapter designates protected water sources, which are subject to additional special conditions regarding water use. Permit applications for water withdrawals from these sources may still be...

437

Ground-water sample collection and analysis plan for the ground-water surveillance project  

SciTech Connect (OSTI)

The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy`s (DOE`s) Hanford Site in support of DOE`s environmental surveillance responsibilities. The purpose of this document is to translate DOE`s General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives.

Bryce, R.W.; Evans, J.C.; Olsen, K.B.

1991-12-01T23:59:59.000Z

438

Ground-water sample collection and analysis plan for the ground-water surveillance project  

SciTech Connect (OSTI)

The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy's (DOE's) Hanford Site in support of DOE's environmental surveillance responsibilities. The purpose of this document is to translate DOE's General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives.

Bryce, R.W.; Evans, J.C.; Olsen, K.B.

1991-12-01T23:59:59.000Z

439

System for detecting and limiting electrical ground faults within electrical devices  

DOE Patents [OSTI]

An electrical ground fault detection and limitation system for employment with a nuclear reactor utilizing a liquid metal coolant. Elongate electromagnetic pumps submerged within the liquid metal coolant and electrical support equipment experiencing an insulation breakdown occasion the development of electrical ground fault current. Without some form of detection and control, these currents may build to damaging power levels to expose the pump drive components to liquid metal coolant such as sodium with resultant undesirable secondary effects. Such electrical ground fault currents are detected and controlled through the employment of an isolated power input to the pumps and with the use of a ground fault control conductor providing a direct return path from the affected components to the power source. By incorporating a resistance arrangement with the ground fault control conductor, the amount of fault current permitted to flow may be regulated to the extent that the reactor may remain in operation until maintenance may be performed, notwithstanding the existence of the fault. Monitors such as synchronous demodulators may be employed to identify and evaluate fault currents for each phase of a polyphase power, and control input to the submerged pump and associated support equipment.

Gaubatz, Donald C. (Cupertino, CA)

1990-01-01T23:59:59.000Z

440

Nonstationary Stochastic Simulation of Strong Ground-Motion Time Histories : Application to the Japanese Database  

E-Print Network [OSTI]

For earthquake-resistant design, engineering seismologists employ time-history analysis for nonlinear simulations. The nonstationary stochastic method previously developed by Pousse et al. (2006) has been updated. This method has the advantage of being both simple, fast and taking into account the basic concepts of seismology (Brune's source, realistic time envelope function, nonstationarity and ground-motion variability). Time-domain simulations are derived from the signal spectrogram and depend on few ground-motion parameters: Arias intensity, significant relative duration and central frequency. These indicators are obtained from empirical attenuation equations that relate them to the magnitude of the event, the source-receiver distance, and the site conditions. We improve the nonstationary stochastic method by using new functional forms (new surface rock dataset, analysis of both intra-event and inter-event residuals, consideration of the scaling relations and VS30), by assessing the central frequency with...

Laurendeau, Aurore; Bonilla, Luis Fabian

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Baseline risk assessment of ground water contamination at the Monument Valley uranium mill tailings site Cane Valley, Arizona  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project consists of the Surface Project (Phase I) and the Ground Water Project (Phase II). Under the UMTRA Surface Project, tailings, radioactive contaminated soil, equipment, and materials associated with the former uranium ore processing at UMTRA Project sites are placed into disposal cells. The cells are designed to reduce radon and other radiation emissions and to minimize further contamination of ground water. Surface cleanup at the Monument Valley UMTRA Project site near Cane Valley, Arizona, was completed in 1994. The Ground Water Project evaluates the nature and extent of ground water contamination that resulted from the uranium ore processing activities. The Ground Water Project is in its beginning stages. Human health may be at risk from exposure to ground water contaminated by uranium ore processing. Exposure could occur by drinking water pumped out of a hypothetical well drilled in the contaminated areas. Adverse ecological and agricultural effects may also result from exposure to contaminated ground water. For example, livestock should not be watered with contaminated ground water. A risk assessment describes a source of contamination, how that contamination reaches people and the environment, the amount of contamination to which people or the ecological environment may be exposed, and the health or ecological effects that could result from that exposure. This risk assessment is a site-specific document that will be used to evaluate current and potential future impacts to the public and the environment from exposure to contaminated ground water. The results of this evaluation and further site investigations will be used to determine a compliance strategy to comply with the UMTRA ground water standards.

NONE

1996-03-01T23:59:59.000Z

442

The prototype of a detector for monitoring the cosmic radiation neutron flux on ground  

SciTech Connect (OSTI)

This work presents a comparison between the results of experimental tests and Monte Carlo simulations of the efficiency of a detector prototype for on-ground monitoring the cosmic radiation neutron flux. The experimental tests were made using one conventional {sup 241}Am-Be neutron source in several incidence angles and the results were compared to that ones obtained with a Monte Carlo simulation made with MCNPX Code.

Lelis Goncalez, Odair; Federico, Claudio Antonio; Mendes Prado, Adriane Cristina; Galhardo Vaz, Rafael; Tizziani Pazzianotto, Mauricio [Instituto de Estudos Avancados - IEAv/DCTA - Sao Jose dos Campos, SP (Brazil); Semmler, Renato [Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP - Sao Paulo, SP (Brazil)

2013-05-06T23:59:59.000Z

443

Ground-Water Table and Chemical Changes in an Alluvial Aquifer During  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional Subject:Ground Source Heat Pump Subprogram Overview

444

Hydraulic pump with in-ground filtration and monitoring capability  

DOE Patents [OSTI]

A hydraulically operated pump is described for in-ground filtering and monitoring of wells or other fluid sources, including a hollow cylindrical pump housing with an inlet and an outlet, filtering devices positioned in the inlet and the outlet, a piston that fits slidably within the pump housing, and an optical cell in fluid communication with the pump housing. A conduit within the piston allows fluid communication between the exterior and one end of the piston. A pair of O-rings form a seal between the inside of the pump housing and the exterior of the piston. A flow valve positioned within the piston inside the conduit allows fluid to flow in a single direction. In operation, fluid enters the pump housing through the inlet, flows through the conduit and towards an end of the pump housing. The piston then makes a downward stroke closing the valve, thus forcing the fluid out from the pump housing into the optical cell, which then takes spectrophotometric measurements of the fluid. A spring helps return the piston back to its starting position, so that a new supply of fluid may enter the pump housing and the downward stroke can begin again. The pump may be used independently of the optical cell, as a sample pump to transport a sample fluid from a source to a container for later analysis.

Hopkins, C.D.; Livingston, R.R.; Toole, W.R. Jr.

1995-01-01T23:59:59.000Z

445

Hydraulic pump with in-ground filtration and monitoring capability  

DOE Patents [OSTI]

A hydraulically operated pump for in-ground filtering and monitoring of ws or other fluid sources, including a hollow cylindrical pump housing with an inlet and an outlet, filtering devices positioned in the inlet and the outlet, a piston that fits slidably within the pump housing, and an optical cell in fluid communication with the pump housing. A conduit within the piston allows fluid communication between the exterior and one end of the piston. A pair of o-rings form a seal between the inside of the pump housing and the exterior of the piston. A flow valve positioned within the piston inside the conduit allows fluid to flow in a single direction. In operation, fluid enters the pump housing through the inlet, flows through the conduit and towards an end of the pump housing. The piston then makes a downward stroke closing the valve, thus forcing the fluid out from the pump housing into the optical cell, which then takes spectrophotometric measurements of the fluid. A spring helps return the piston back to its starting position, so that a new supply of fluid may enter the pump housing and the downward stroke can begin again. The pump may be used independently of the optical cell, as a sample pump to transport a sample fluid from a source to a container for later analysis.

Hopkins, Charles D. (Augusta, GA); Livingston, Ronald R. (Aiken, SC); Toole, Jr., William R. (Aiken, SC)

1996-01-01T23:59:59.000Z

446

Hydraulic pump with in-ground filtration and monitoring capability  

DOE Patents [OSTI]

A hydraulically operated pump is described for in-ground filtering and monitoring of waters or other fluid sources, includes a hollow cylindrical pump housing with an inlet and an outlet, filtering devices positioned in the inlet and the outlet, a piston that fits slidably within the pump housing, and an optical cell in fluid communication with the pump housing. A conduit within the piston allows fluid communication between the exterior and one end of the piston. A pair of o-rings form a seal between the inside of the pump housing and the exterior of the piston. A flow valve positioned within the piston inside the conduit allows fluid to flow in a single direction. In operation, fluid enters the pump housing through the inlet, flows through the conduit and towards an end of the pump housing. The piston then makes a downward stroke closing the valve, thus forcing the fluid out from the pump housing into the optical cell, which then takes spectrophotometric measurements of the fluid. A spring helps return the piston back to its starting position, so that a new supply of fluid may enter the pump housing and the downward stroke can begin again. The pump may be used independently of the optical cell, as a sample pump to transport a sample fluid from a source to a container for later analysis. 5 figs.

Hopkins, C.D.; Livingston, R.R.; Toole, W.R. Jr.

1996-10-29T23:59:59.000Z

447

Ground motion data for International Collider models  

SciTech Connect (OSTI)

The proposed location for the International Linear Collider (ILC) in the Americas region is Fermilab in Batavia Illinois. If built at this location the tunnels would be located in the Galena Platteville shale at a depth of 100 or more meters below the surface. Studies using hydro static water levels and seismometers have been conducted in the MINOS hall and the LaFrange Mine in North Aurora Illinois to determine the level of ground motion. Both these locations are in the Galena Platteville shale and indicate the typical ground motion to be expected for the ILC. The data contains both natural and cultural noise. Coefficients for the ALT law are determined. Seismic measurements at the surface and 100 meters below the surface are presented.

Volk, J.T.; LeBrun, P.; Shiltsev, V.; Singatulin, S.; /Fermilab

2007-11-01T23:59:59.000Z

448

GEOMETRIC SOURCE SEPARATION: MERGING CONVOLUTIVE SOURCE  

E-Print Network [OSTI]

adaptive beamforming algorithms by a cross-power criteria, we gain new geometric source separation with convo- lutive blind source separation. We concentrate on cross-power spectral min- imization which is su to ambiguities in the choice of separating lters. There are in theory multiple lters that invert the room

Parra, Lucas C.

449

Compression of ground-motion data  

SciTech Connect (OSTI)

Ground motion data has been recorded for many years at Nevada Test Site and is now stored on thousands of digital tapes. The recording format is very inefficient in terms of space on tape. This report outlines a method to compress the data onto a few hundred tapes while maintaining the accuracy of the recording and allowing restoration of any file to the original format for future use. For future digitizing a more efficient format is described and suggested.

Long, J.W.

1981-04-01T23:59:59.000Z

450

R/Blkstripe CTB Ground Strap  

E-Print Network [OSTI]

5 5 4 4 3 3 2 2 1 1 D D C C B B A A Orange Black Yellow Blue R/Blkstripe Tan Red CTB Ground Strap Title Size Document Number R ev Date: Sheet o f ? ToFr 2003_S Run 4 L.V Setup Rice. U. Bonner Lab B 1 1, Limited (picoFuse) @ 3.0 A 7x"VNTC"#14awgrated17A Actualoperating=7.7Amax. LOW VOLTAGE SUPPLY SETTINGS

Llope, William J.

451

Ground motion: An introduction for accelerator builders  

SciTech Connect (OSTI)

In this seminar we will review some of the characteristics of the major classes of ground motion in order to determine whether their effects must be considered or place fundamental limits on the sitting and/or design of modern storage rings and linear colliders. The classes discussed range in frequency content from tidal deformation and tectonic motions through earthquakes and microseisms. Countermeasures currently available are briefly discussed.

Fischer, G.E.

1992-02-01T23:59:59.000Z

452

Ground Electromagnetic Techniques | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to: navigation,Ohio:Greer County is a county in Oklahoma.Groom Energy SolutionsGround

453

Sprites, elf transients, and positive ground strokes  

SciTech Connect (OSTI)

In two summertime mesoscale convective systems (MCSs), mesospheric optical sprite phenomena were often coincident with both large-amplitude positive cloud-to-ground lightning and transient Schumann resonance excitations of the entire Earth-ionosphere cavity. These observations, together with earlier studies of MCS electrification, suggest that sprites are triggered when the rapid removal of large quantities of positive charge from an areally extensive charge layer stresses the mesosphere to dielectric breakdown. 46 refs., 7 figs., 1 tab.

Boccippio, D.J.; Boldi, R.; Williams, E.R. [Massachusetts Inst. of Technology, Cambridge, MA (United States)] [and others

1995-08-25T23:59:59.000Z

454

Ground-Coupled Heat Pump Applications and Case Studies  

E-Print Network [OSTI]

The paper presents an overview of ground loops for space-conditioning heat pumps, hot water, ice machines, and water-cooled refrigeration in residential and commercial applications. In Louisiana, a chain of hamburger drive-ins uses total ground...

Braud, H. J.

1989-01-01T23:59:59.000Z

455

Talking In Circles: Designing A Spatially-Grounded Audioconferencing Environment  

E-Print Network [OSTI]

to become a popular medium for social interaction. Traditional chat environments, however, are limitedTalking In Circles: Designing A Spatially-Grounded Audioconferencing Environment Roy Rodenstein, a multimodal audioconferencing environment whose novel design emphasizes spatial grounding with the aim

456

The Design of Ground-Coupled Heat Pump Systems  

E-Print Network [OSTI]

Ground-coupled heat pumps are being installed in increasing numbers due to proven performance and economy. The overall thermal resistance between the ground coupling fluid and a given type of surrounding soil is affected by pipe material, wall...

Parker, J. D.

1985-01-01T23:59:59.000Z

457

Recommendation 195: Mitigation of Contamination in Bear Creek Burial Grounds  

Broader source: Energy.gov [DOE]

The ORSSAB requests DOE provide possible remedial actions to mitigate releases of contamination from Bear Creek Burial Grounds.

458

Cooperative heat transfer and ground coupled storage system  

DOE Patents [OSTI]

A cooperative heat transfer and ground coupled storage system wherein collected solar heat energy is ground stored and permitted to radiate into the adjacent ground for storage therein over an extended period of time when such heat energy is seasonally maximally available. Thereafter, when said heat energy is seasonally minimally available and has propagated through the adjacent ground a substantial distance, the stored heat energy may be retrieved by a circumferentially arranged heat transfer means having a high rate of heat transfer.

Metz, Philip D. (Rocky Point, NY)

1982-01-01T23:59:59.000Z

459

Performance Evaluation of a ground source heat pump system based on ANN and ANFIS models  

E-Print Network [OSTI]

-mail address: pingfanghu21@163.com, pingfanghu@hust.edu.cn (P.Hu) ESL-IC-14-09-38 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 air temperature leaving/entering the condenser... the evaporator temperature, condenser temperature, sub cooling temperature, superheating temperature and cooling capacity. ZHAO Jing [6,7] made a post evaluation before the renovation of a central air-conditioning system of a large-scale public building and a...

Sun, W.; Hu, P.; Lei, F.; Zhu, N.; Zhang,J.

2014-01-01T23:59:59.000Z

460

Recovery Act - Geothermal Technologies Program: Ground Source Heat Pumps Final Scientific/Technical Report  

SciTech Connect (OSTI)

A large centralized geothermal heat pump system was installed to provide ice making, space cooling, space heating, process water heating, and domestic hot water heating for an ice arena in Eagan Minnesota. This paper provides information related to the design and construction of the project. Additionally, operating conditions for 12 months after start-up are provided.

Nick Rosenberry, Harris Companies

2012-05-04T23:59:59.000Z

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Ball State Completes Largest U.S. Ground-Source Geothermal System...  

Office of Environmental Management (EM)

comprising 5.5 million square feet on the 660-acre campus. To provide heating, geothermal heat pumps use a fluid to transfer heat from the Earth to buildings. For cooling, the...

462

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network [OSTI]

simulation with credible software programs is a proven feasible way to get quantitative comparison of the energy

Hong, Tainzhen

2010-01-01T23:59:59.000Z

463

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network [OSTI]

the current movement toward net zero energy buildings, manyThe movement towards net zero energy buildings brings

Hong, Tainzhen

2010-01-01T23:59:59.000Z

464

Comparison of energy efficiency between variable refrigerant flow systems and ground source heat pump systems  

E-Print Network [OSTI]

Comparison of energy efficiency between variable refrigeranttheir superior energy efficiency. The variable refrigerantfew studies reporting the energy efficiency of VRF systems

Hong, Tainzhen

2010-01-01T23:59:59.000Z

465

GEO Down Under The Ground Source Industry in Australia and New Zealand  

E-Print Network [OSTI]

: 22.2 million § GDP: $987 billion § Per capita GDP: $43 300 per capita § Popula8on: 4.4 million § GDP: $134 billion § Per capita GDP: $30 200 rocks and energy genera8on to most § North side of house has greatest solar

466

Characterization of ammonia emissions from ground level area sources at central texas dairies  

E-Print Network [OSTI]

for the free-stall dairy were determined to be 11.1 ±4.9 kg NH3 year-1 head-1 for summer season and 4.7± 4.9 kg NH3 year-1 head-1 for winter season. The estimated annual NH3 EF was 8.4 ±4.9 kg NH3 year-1 head-1 for this free-stall dairy. In winter, composted...

Mutlu, Atilla

2009-05-15T23:59:59.000Z

467

Ball State Completes Largest U.S. Ground-Source Geothermal System |  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EERE BlogAttachmentFlash2011-21FAQs BEDES| Department ofDepartment of

468

Advanced Ground Source Heat Pump Technology for Very-Low-Energy Buildings |  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3-- ------------------------------Chapter 39.208-006EnergyFossil EnergyDepartment of

469

Comparison of Aermod and ISCST3 Models for Particulate Emissions from Ground Level Sources  

E-Print Network [OSTI]

......................................................................................................................... 95 x LIST OF FIGURES Page Figure 1. Schematic of the Flocchini box model.............................................................. 7 Figure 2. Layout of test plots... in Table 1. EFs developed using the two modeling methods were found not to be statistically different for all the four species at the 95% confidence level. No difference was observed even in the standard deviation values of the EFs developed using...

Botlaguduru, Venkata Sai V.

2010-07-14T23:59:59.000Z

470

Tennessee: Ground-Source Heat Pump Receives Innovation Award at AHR Expo |  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomenthe House Committee on EnergyEnergy Secretary ChuAsWhatTheTed Donat -A

471

Air dispersion modeling of particulate matter from ground-level area sources  

E-Print Network [OSTI]

State Air Pollution Regulatory Agencies (SAPRAs) often use dispersion modeling to predict downwind concentrations of particulate matter (PM) from a facility. As such, a facility may be granted or denied an operating permit based on the results...

Meister, Michael Todd

2000-01-01T23:59:59.000Z

472

On Termination and Derivation Lengths for Ground Rewrite Systems  

E-Print Network [OSTI]

On Termination and Derivation Lengths for Ground Rewrite Systems Dieter Hofbauer 1 Universit¨at GH@theory.informatik.uni­kassel.de Abstract. It is shown that for terminating ground term rewrite systems the length of derivations a suitable interpretation into the natural numbers. Terminating ground systems are not necessarily

Giesl, Juergen

473

Basic Ground-Water Hydrology By RALPH C. HEATH  

E-Print Network [OSTI]

#12;Basic Ground-Water Hydrology By RALPH C. HEATH Prepared in cooperation with the North Carolina., 1983, Basic ground-water hydrology: U .S. Geological Survey Water-Supply Paper 2220, 86 p. Library of Congress Cataloging-in-Publications Data Heath, Ralph C . Basic ground-water hydrology (Geological Survey

Sohoni, Milind

474

Regional Estimation of Total Recharge to Ground Water in Nebraska  

E-Print Network [OSTI]

)over long periods of time when the potential change in ground water storage becomes negligible compared storage other than discharge to streams. One such loss term is evapotranspiration (ET) from ground waterRegional Estimation of Total Recharge to Ground Water in Nebraska by Jozsef Szilagyi1m2,F. Edwin

Szilagyi, Jozsef

475

Materialized community ground models for large-scale earthquake simulation  

E-Print Network [OSTI]

Materialized community ground models for large-scale earthquake simulation Steven W. Schlosser to ground motion sim- ulations, in which ground model datasets are fully materi- alized into octress stored as a service techniques in which scientific computation and storage services become more tightly intertwined. 1

Shewchuk, Jonathan

476

DEVELOPMENTS IN GROUND WATER HYDROLOGY : AN OVERVIEW C. P. Kumar  

E-Print Network [OSTI]

. Surface water storage and ground water withdrawal are traditional engineering approaches which of storage and circulation as ground water. The large alluvial tract extending over 2000 km in length from which allows ground water storage in the weathered residium and its circulation in the underlying

Kumar, C.P.

477

Advanced fenestration systems for improved daylight performance  

E-Print Network [OSTI]

SPIE Optical Materials Technology for Energy Efficiency andon Optical Materials Technology for Energy Efficiency andon Optical Materials Technology for Energy Efficiency and

Selkowitz, S.; Lee, E.S.

1998-01-01T23:59:59.000Z

478

Experimental Evaluation of Innovative Wall Daylighting Systems  

E-Print Network [OSTI]

to deliver most of the light from the projecting mirror to the two inner spaces. One way of doing this without causing glare to the occupants is to project the light on the area of ceiling over the two spaces and allow the ceiling to serve aa a secondary.... Providing illumination in buildings using sunlight as a substitute for electric light is attractive for several reasons: 1. The solar illumination resource is substantial; during most working hours, the solar illumination on a building is several times...

Place, J. W.; Howard, T. C.; Paulos, S.; Chung, K.

1988-01-01T23:59:59.000Z

479

Advanced fenestration systems for improved daylight performance  

E-Print Network [OSTI]

technology for dynamic, smart glazings has the potential toSwitchable Glazing: Towards the Development of the Smart

Selkowitz, S.; Lee, E.S.

1998-01-01T23:59:59.000Z

480

List of Daylighting Incentives | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth's Heat JumpInc Place:KeystoneSolar (Texas)Biofuels SectorIncentives. CSV (rows

Note: This page contains sample records for the topic "daylighting ground source" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Advanced Facades, Daylighting, and Complex Fenestration Systems |  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3-- ------------------------------Chapter 39.208-006Energy

482

Times are in Mountain Daylight Savings Time  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of EnergyThe EnergyDepartment7 th , 2007 AnthonyDepartmentofGeothermalATF

483

Times are in Mountain Daylight Savings Time  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage »of EnergyThe EnergyDepartment7 th , 2007

484

THE INTEGRATED APPROACH TIPS FOR DAYLIGHTING  

E-Print Network [OSTI]

approach to the cost-effective design of perimeter zones in new commercial buildings and existing building retrofits. They function as a quick reference for building designers, through a set of easy steps and rules the reader wish to go further. The design method used in this document emphasizes that building decisions

485

CALIFORNIA ENERGY Daylight and Retail Sales  

E-Print Network [OSTI]

through the integrated design, construction, and operation of building systems. The Integrated Energy to the final report of a larger research effort called Integrated Energy Systems: Productivity and Building Heschong, Project Director Fair Oaks, California Managed By: New Buildings Institute Cathy Higgins, Program

486

Lighting and Daylighting Basics | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE: Alternative Fuels DataCombined HeatInformation ResourcesIsland EnergyLabLeadershipLessons

487

Advanced Facades, Daylighting, and Complex Fenestration Systems  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartment of EnergyAdministrative2 DOE Hydrogen andEnzyme

488

Energy 101: Daylighting | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation ProposedUsing Zirconia Nanoparticles asSecond stage ofDefects on . GradeCool Roofs Energy

489

Energy 101: Daylighting | Department of Energy  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation ProposedUsing Zirconia Nanoparticles asSecond stage ofDefects on . GradeCool Roofs

490

Window Daylighting Demo | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of EnergyofProject isNovember 07, 2007What Isand SupplyEnergy Wind and

491

Photovoltaic module mounting clip with integral grounding  

DOE Patents [OSTI]

An electrically conductive mounting/grounding clip, for use with a photovoltaic assembly of the type having an electrically conductive frame, comprises an electrically conductive body. The body has a central portion and first and second spaced-apart arms extending generally perpendicular to the central portion. Each arm has an outer portion with each outer portion having an outer end. At least one frame surface-disrupting element is at each outer end. The central portion defines a plane with the frame surface-disrupting elements pointing towards the plane. In some examples each arm extends from the central portion at an acute angle to the plane.

Lenox, Carl J.

2008-10-14T23:59:59.000Z

492

Geometric renormalization below the ground state  

E-Print Network [OSTI]

The caloric gauge was introduced by Tao with studying large data energy critical wave maps mapping from $\\mathbf{R}^{2+1}$ to hyperbolic space $\\mathbf{H}^m$ in view. In \\cite{BIKT} Bejenaru, Ionescu, Kenig, and Tataru adapted the caloric gauge to the setting of Schr\\"odinger maps from $\\mathbf{R}^{d + 1}$ to the standard sphere $S^2 \\hookrightarrow \\mathbf{R}^3$ with initial data small in the critical Sobolev norm. Here we develop the caloric gauge in a bounded geometry setting with a construction valid up to the ground state energy.

Paul Smith

2011-12-06T23:59:59.000Z

493

Best Possible Strategy for Finding Ground States  

SciTech Connect (OSTI)

Finding the ground state of a system with a complex energy landscape is important for many physical problems including protein folding, spin glasses, chemical clusters, and neural networks. Such problems are usually solved by heuristic search methods whose efficacy is judged by empirical performance on selected examples. We present a proof that, within the large class of algorithms that simulate a random walk on the landscape, threshold accepting is the best possible strategy. In particular, it can perform better than simulated annealing and Tsallis statistics. Our proof is the first example of a provably optimal strategy in this area.

Franz, Astrid; Hoffmann, Karl Heinz; Salamon, Peter

2001-06-04T23:59:59.000Z

494

Ground-Based Microwave Radiometer Measurements  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth7-1D: Vegetation ProposedUsingFun with Big Sky LearningGetGraphene's 3DRise |EnergyVehicles andGround-Based

495

Ground Gravity Survey | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth's Heat Jump to:Photon Place:Net Jump to: navigation,2004)EnergyGround Gravity

496

Ground Magnetics (Nannini, 1986) | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home5b9fcbce19 No revision hasInformation Earth's Heat Jump to:Photon Place:Net Jump to: navigation,2004)EnergyGround

497

120 Ground Water Monitoring & Remediation 32, no. 1/ Winter 2012/pages 120130 NGWA.org Ground Water Monitoring & Remediation  

E-Print Network [OSTI]

120 Ground Water Monitoring & Remediation 32, no. 1/ Winter 2012/pages 120­130 NGWA.org Ground Water Monitoring & Remediation © 2011, National Ground Water Association. Published 2011. This article known as emerging contaminants (ECs) to surrounding groundwater and surface water. ECs consist

498

Understanding open source in an industrial context Sven Ziemer, yvind Hauge and Thomas sterlie  

E-Print Network [OSTI]

of software development that will revolution- ize the software industry [2]. A recent addition to the onUnderstanding open source in an industrial context Sven Ziemer, Ã?yvind Hauge and Thomas Ã?sterlie source in an industrial context. Building a grounded theory from an industry-driven R&D project, our

499

Free and Open Source Software for Development  

E-Print Network [OSTI]

Development organizations and International Non-Governmental Organizations have been emphasizing the high potential of Free and Open Source Software for the Less Developed Countries. Cost reduction, less vendor dependency and increased potential for local capacity development have been their main arguments. In spite of its advantages, Free and Open Source Software is not widely adopted at the African continent. In this book the authors will explore the grounds on with these expectations are based. Where do they come from and is there evidence to support these expectations? Over the past years several projects have been initiated and some good results have been achieved, but at the same time many challenges were encountered. What lessons can be drawn from these experiences and do these experiences contain enough evidence to support the high expectations? Several projects and their achievements will be considered. In the final part of the book the future of Free and Open Source Software for Development will be explored. Special attention is given to the African continent since here challenges are highest. What is the role of Free and open Source Software for Development and how do we need to position and explore the potential? What are the threats? The book aims at professionals that are engaged in the design and implementation of ICT for Development (ICT4D) projects and want to improve their understanding of the role Free and Open Source Software can play.

Victor van Reijswoud; Arjan de Jager

2008-08-27T23:59:59.000Z

500

Baseline risk assessment of ground water contamination at the uranium mill tailings site near Salt Lake City, Utah. Revision 1  

SciTech Connect (OSTI)

The Uranium Mill Tailings Remedial Action (UMTRA) Project consists of two phases: the first is the Surface Project, and the second is the Ground Water Project. For the UMTRA Project site known as the Vitro site, near Salt Lake City, Utah, Surface Project cleanup occurred from 1985 to 1987. The UMTRA Project`s second phase, the Ground Water Project, evaluates the nature and extent of ground water contamination resulting from uranium processing and determines a strategy for ground water compliance with the Environmental Protection Agency (EPA) ground water standards established for the UMTRA Project. A risk assessment is the process of describing a source of contamination and showing how that contamination may reach people and the environment. The amount of contamination people or the environment may be exposed to is calculated and used to characterize the possible health or environmental effects that may result from this exposure. This risk assessment report is the first site-specific document prepared for the UMTRA Ground Water Project at the Vitro site. The results of this report and further site characterization of the Vitro site will be used to determine what is necessary, if anything, to protect human health and the environment while complying with EPA standards.

NONE

1995-09-01T23:59:59.000Z