Powered by Deep Web Technologies
Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Oil Bypass Filter Technology Evaluation - Fourth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

ABSTRACT This fourth Oil Bypass Filter Technology Evaluation report details the ongoing fleet evaluation of an oil bypass filter technology by the Idaho National Engineering and...

2

Oil Bypass filter technology evaluation final report  

NLE Websites -- All DOE Office Websites (Extended Search)

6-01355 6-01355 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Final Report TECHNICAL REPORT Larry Zirker James Francfort Jordan Fielding March 2006 Idaho National Laboratory Operated by Battelle Energy Alliance INL/EXT-06-01355 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Final Report Larry Zirker James Francfort Jordan Fielding March 2006 Idaho National Laboratory Transportation Technology Department Idaho Falls, Idaho 83415 Prepared for the U.S. Department of Energy Assistant Secretary for Energy Efficiency and Renewable Energy Under DOE Idaho Operations Office Contract DE-AC07-05ID14517

3

Oil Bypass Filter Technology Evaluation - Second Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-03-00620 U.S. Department of Energy FreedomCAR & Vehicle Technologies Oil Bypass Filter Technology Evaluation Second Quarterly Report January - March 2003 Larry Zirker...

4

Oil Bypass Filter Technology Evaluation - Fifth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-04-01618 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Fifth Quarterly Report October - December 2003...

5

Oil Bypass Filter Technology Evaluation - Eighth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-04-02486 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Eighth Quarterly Report July-September 2004...

6

Demonstrated Petroleum Reduction Using Oil Bypass Filter Technology...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy FreedomCAR & Vehicle Technologies Program Demonstrated Petroleum Reduction Using Oil Bypass Filter Technology on Heavy and Light Vehicles James Francfort (PI) Timothy...

7

Oil Bypass Filter Technology Performance Evaluation - First Quarterly...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-03-00129 U.S. Department of Energy FreedomCAR & Vehicle Technologies Oil Bypass Filter Technology Performance Evaluation First Quarterly Report Larry Zirker James...

8

Oil Bypass Filter Technology Evaluation - Sixth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-04-02004 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Sixth Quarterly Report January - March 2004...

9

Oil Bypass Filter Technology Evaluation - Tenth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INLEXT-05-00381 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Tenth Quarterly Report January-March 2005 TECHNICAL...

10

Oil Bypass Filter Technology Evaluation - Third Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INEELEXT-03-00974 U.S. Department of Energy FreedomCAR & Vehicle Technologies Oil Bypass Filter Technology Evaluation Third Quarterly Report April-June 2003 Larry Zirker James...

11

Oil Bypass Filter Technology Evaluation - Ninth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

INLEXT-05-00040 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Ninth Quarterly Report October-December 2004 TECHNICAL...

12

Oil Bypass Filter Technology Performance Evaluation - First Quarterly Report  

DOE Green Energy (OSTI)

This report details the initial activities to evaluate the performance of the oil bypass filter technology being tested by the Idaho National Engineering and Environmental Laboratory (INEEL) for the U.S. Department of Energy's FreedomCAR & Vehicle Technologies Program. Eight full-size, four-cycle diesel-engine buses used to transport INEEL employees on various routes have been equipped with oil bypass systems from the puraDYN Corporation. Each bus averages about 60,000 miles a year. The evaluation includes an oil analysis regime to monitor the presence of necessary additives in the oil and to detect undesirable contaminants. Very preliminary economic analysis suggests that the oil bypass system can reduce life-cycle costs. As the evaluation continues and oil avoidance costs are quantified, it is estimated that the bypass system economics may prove increasingly favorable, given the anticipated savings in operational costs and in reduced use of oil and waste oil avoidance.

Zirker, L.R.; Francfort, J.E.

2003-01-31T23:59:59.000Z

13

Evaluation of Oil Bypass Filter Technology on Heavy-Duty Vehicles  

NLE Websites -- All DOE Office Websites (Extended Search)

(Advanced Vehicle Testing Activity) (Advanced Vehicle Testing Activity) Evaluation of Oil Bypass Filter Technology on Heavy-Duty Vehicles James Francfort American Filtration and Separations Society April 2005 Presentation Outline * Background & Objectives * Oil bypass filters - features & reported benefits * INL testing method * puraDYN oil bypass filters * Refined Global Solutions (RGS) oil bypass filters * Testing results & trends * Particulate and ferrography testing * Initial INL Oil Bypass Filter Economics * Potential fleet oil savings * Testing Status Bypass Filter Evaluation - Background * Funded by the U.S. Department of Energy's FreedomCAR & Vehicle Technologies Program (Advanced Vehicle Testing Activity) * Vehicles operated by Idaho National Laboratory's Fleet Operations group * Idaho National Laboratory

14

Demonstrated Petroleum Reduction Using Oil Bypass Filter Technology on Heavy and Light Vehicles  

NLE Websites -- All DOE Office Websites (Extended Search)

Demonstrated Petroleum Demonstrated Petroleum Reduction Using Oil Bypass Filter Technology on Heavy and Light Vehicles James Francfort (PI) Timothy Murphy Larry Zirker Oil Bypass Filter Technology Evaluation * Funded by the U.S. Department of Energy's FreedomCAR & Vehicle Technologies Program * Performed by Idaho National Engineering and Environmental Laboratory (INEEL) Fleet Operations * Goal - Support DOE's efforts to reduce petroleum consumption & ensure the energy security of the United States Oil Bypass Filter Technology Evaluation * Objectives - Test the concept of using oil bypass filters to minimize engine oil changes & the generation of waste oils - Demonstration the economics of oil bypass filter systems - Estimate potential engine oil saving from bypass filter technologies that can be achieved by INEEL,

15

Advanced Vehicle Testing Activity: Oil Bypass Filter  

NLE Websites -- All DOE Office Websites (Extended Search)

Oil Bypass Filter The Idaho National Laboratory (INL) is evaluating oil bypass filter technology for the U.S. Department of Energy's (DOE's) Vehicle Technologies Office. Eight...

16

Oil Bypass Filter Technology Evaluation, Fourth Quarterly Report, July--September 2003  

Science Conference Proceedings (OSTI)

This fourth Oil Bypass Filter Technology Evaluation report details the ongoing fleet evaluation of an oil bypass filter technology by the Idaho National Engineering and Environmental Laboratory (INEEL) for the U.S. Department of Energy’s FreedomCAR & Vehicle Technologies Program. Eight four-cycle diesel-engine buses used to transport INEEL employees on various routes have been equipped with oil bypass filter systems from the puraDYN Corporation. The bypass filters are reported to have engine oil filtering capability of miles. This represents an avoidance of 21 oil changes, which equates to 740 quarts (185 gallons) of oil not used or disposed of. To validate the extended oil-drain intervals, an oil-analysis regime evaluates the fitness of the oil for continued service by monitoring the presence of necessary additives, undesirable contaminants, and engine-wear metals. For bus 73450, higher values of iron have been reported, but the wear rate ratio (parts per million of iron per thousand miles driven) has remained consistent. In anticipation of also evaluating oil bypass systems on six Chevrolet Tahoe sport utility vehicles, the oil is being sampled on each of the Tahoes to develop a characterization history or baseline for each engine.

James E. Francfort; Larry Zirker

2003-11-01T23:59:59.000Z

17

Oil Bypass Filter Technology Evaluation Ninth Quarterly Report October–December 2004  

SciTech Connect

This Oil Bypass Filter Technology Evaluation quarterly report (October–December 2004) details the ongoing fleet evaluation of oil bypass filter technologies being conducted by the Idaho National Laboratory (INL; formerly Idaho National Engineering and Environmental Laboratory) for the U.S. Department of Energy’s FreedomCAR & Vehicle Technologies Program. Eight INL four-cycle diesel-engine buses used to transport INL employees on various routes and six INL Chevrolet Tahoes with gasoline engines are equipped with oil bypass filter systems from the puraDYN Corporation. This quarter, three additional buses were equipped with bypass filters from Refined Global Solutions. Oil bypass filters are reported to have an engine oil filtering capability of less than 1 micron. Both the puraDYN and Refined Global Solutions bypass filters have a heating chamber to remove liquid contaminate from the oil. During the quarter, the eleven diesel engine buses traveled 62,188 miles, and as of January 3, 2005 the buses had accumulated 643,036 total test miles. Two buses had their engine oil changed this quarter. In one bus, the oil was changed due to its degraded quality as determined by a low total base number (<3.0 mg KOH/g). The other bus had high oxidation and nitration numbers (>30.0 Abs/cm). Although a total of six buses have had their oil changed during the last 26 months, by using the oil bypass filters the buses in the evaluation avoided 48 oil changes, which equates to 1,680 quarts (420 gallons) of new oil not consumed and 1,680 quarts of waste oil not generated. Therefore, over 80% of the oil normally required for oil-changes was not used, and, consequently, the evaluation achieved over 80% reduction in the amount of waste oil normally generated. The six Tahoe test vehicles traveled 39,514 miles, and as of January 3, 2005 the Tahoes had accumulated 189,970 total test miles. The Tahoe filter test is in transition. To increase the rate of bypass filter oil flow on the Tahoes, puraDYN provided a larger orifice assembly, and these are being changed out as the Tahoes come in for regular service.

Larry Zirker; James Francfort; Jordan Fielding

2005-02-01T23:59:59.000Z

18

Oil Bypass Filter Technology Evaluation Eleventh Quarterly Report April- June 2005  

NLE Websites -- All DOE Office Websites (Extended Search)

651 651 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Eleventh Quarterly Report April-June 2005 TECHNICAL REPORT Larry Zirker James Francfort Jordan Fielding September 2005 Idaho National Laboratory Operated by Battelle Energy Alliance INL/EXT-05-00651 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Eleventh Quarterly Report April-June 2005 Larry Zirker James Francfort Jordan Fielding September 2005 Idaho National Laboratory Transportation Technology Department Idaho Falls, Idaho 83415 Prepared for the U.S. Department of Energy Assistant Secretary for Energy Efficiency and Renewable Energy Under DOE Idaho Operations Office

19

Oil Bypass Filter Technology Evaluation - Seventh Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

Technology Laboratory-WV National Renewable Energy Laboratory Naval Petroleum and Oil Shale Reserves CO, UT, WY Nevada Site Office Nevada Test Site Oak Ridge Institute for...

20

Oil Bypass Filter Technology Evaluation Seventh Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

Technology Laboratory-WV National Renewable Energy Laboratory Naval Petroleum and Oil Shale Reserves CO, UT, WY Nevada Site Office Nevada Test Site Oak Ridge Institute for...

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Final Report  

SciTech Connect

This Oil Bypass Filter Technology Evaluation final report documents the feasibility of using oil bypass filters on 17 vehicles in the Idaho National Laboratory (INL) fleet during a 3-year test period. Almost 1.3 million test miles were accumulated, with eleven 4-cycle diesel engine buses accumulating 982,548 test miles and six gasoline-engine Chevrolet Tahoes accumulating 303,172 test miles. Two hundred and forty oil samples, taken at each 12,000-mile bus servicing event and at 3,000 miles for the Tahoes, documented the condition of the engine oils for continued service. Twenty-eight variables were normally tested, including the presence of desired additives and undesired wear metals such as iron and chrome, as well as soot, water, glycol, and fuel. Depending on the assumptions employed, the INL found that oil bypass filter systems for diesel engine buses have a positive payback between 72,000 and 144,000 miles. For the Tahoes, the positive payback was between 66,000 and 69,000 miles.

L. R. Zirker; J. E. Francfort; J. J. Fielding

2006-03-01T23:59:59.000Z

22

Advanced Vehicle Testing Activity: Oil Bypass Filter  

NLE Websites -- All DOE Office Websites (Extended Search)

Oil Bypass Filter to someone by E-mail Share Advanced Vehicle Testing Activity: Oil Bypass Filter on Facebook Tweet about Advanced Vehicle Testing Activity: Oil Bypass Filter on...

23

Advanced Vehicle Testing Activity: Oil Bypass Filter Testing...  

NLE Websites -- All DOE Office Websites (Extended Search)

Testing Reports to someone by E-mail Share Advanced Vehicle Testing Activity: Oil Bypass Filter Testing Reports on Facebook Tweet about Advanced Vehicle Testing Activity: Oil...

24

Advanced Vehicle Testing Activity: Oil Bypass Filter Specifications...  

NLE Websites -- All DOE Office Websites (Extended Search)

and Test Procedures to someone by E-mail Share Advanced Vehicle Testing Activity: Oil Bypass Filter Specifications and Test Procedures on Facebook Tweet about Advanced...

25

Advanced Vehicle Testing Activity - Oil Bypass Filtration Evaluation  

NLE Websites -- All DOE Office Websites (Extended Search)

Oil Bypass Filtration Evaluation These reports detail the ongoing fleet evaluation of oil bypass filter technologies by the Idaho National Laboratory (INL) for the U. S. Department...

26

2009 ASHRAE 199 The issue of filter bypass has long been a topic of much  

E-Print Network (OSTI)

©2009 ASHRAE 199 ABSTRACT The issue of filter bypass has long been a topic of much interest on filtration efficiency. In this research, an ASHRAE 52.2 compliant test loop was used to study bypass, a test apparatus designed to ASHRAE Standard 52.2-2007 was used. This standard provides a methodology

Siegel, Jeffrey

27

Nuclear Filter Technology | Open Energy Information  

Open Energy Info (EERE)

located in Golden, CO. References Retrieved from "http:en.openei.orgwindex.php?titleNuclearFilterTechnology&oldid379255" Categories: Clean Energy Organizations Companies...

28

Advanced Vehicle Testing Activity - Oil Bypass Filtration Evaluation  

NLE Websites -- All DOE Office Websites (Extended Search)

with oil bypass filter systems from PuraDYN Filter Technologies (8 buses) and Refined Global Solutions (3 buses). Six gasoline-equipped INL Tahoes are also equipped with PuraDYN...

29

Oil Bypass Filter Technology Evaluation Ninth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

Background on prior quarterly reports * Bus mileage and performance status * Used engine-oil disposal costs * Unscheduled oil change * Light-duty vehicle test status Oct 3-Dec 3...

30

Oil Bypass Filter Technology Evaluation Eighth Quarterly Report...  

NLE Websites -- All DOE Office Websites (Extended Search)

Background on prior quarterly reports * Bus mileage and performance status * Used engine-oil disposal costs * Unscheduled oil change * Light-duty vehicle test status Oct 3-Dec 3...

31

Available Technologies: Island Vane Macroparticle Filter for ...  

Energy Efficiency; Energy Storage and Recovery; Renewable Energy; Environmental Technologies. Monitoring and Imaging; Remediation; Modeling; Imaging ...

32

Performance-Based Technology Selection Filter description report  

SciTech Connect

A formal methodology has been developed for identifying technology gaps and assessing innovative or postulated technologies for inclusion in proposed Buried Waste Integrated Demonstration (BWID) remediation systems. Called the Performance-Based Technology Selection Filter, the methodology provides a formalized selection process where technologies and systems are rated and assessments made based on performance measures, and regulatory and technical requirements. The results are auditable, and can be validated with field data. This analysis methodology will be applied to the remedial action of transuranic contaminated waste pits and trenches buried at the Idaho National Engineering Laboratory (INEL).

O' Brien, M.C.; Morrison, J.L.; Morneau, R.A.; Rudin, M.J.; Richardson, J.G.

1992-05-01T23:59:59.000Z

33

Improved HEPA Filter Technology for Flexible and Rigid Containment Barriers  

SciTech Connect

Safety and reliability in glovebox operations can be significantly improved and waste packaging efficiencies can be increased by inserting flexible, lightweight, high capacity HEPA filters into the walls of plastic sheet barriers. This HEPA filter/barrier technology can be adapted to a wide variety of applications: disposable waste bags, protective environmental barriers for electronic equipment, single or multiple use glovebag assemblies, flexible glovebox wall elements, and room partitions. These reliable and inexpensive filtered barriers have many uses in fields such as radioactive waste processing, HVAC filter changeout, vapor or grit blasting, asbestos cleanup, pharmaceutical, medical, biological, and electronic equipment containment. The applications can result in significant cost savings, improved operational reliability and safety, and total waste volume reduction. This technology was developed at the Argonne National Laboratory-West (ANL-W) in 1993 and has been used at ANL-W since then at the TRU Waste Characterization Chamber Gloveboxes. Another 1998 AGS Conference paper titled "TRU Waste Characterization Gloveboxes", presented by Mr. David Duncan of ANL-W, describes these boxes.

P. A. Pinson

1998-07-01T23:59:59.000Z

34

Program on Technology Innovation: Advanced Filter Concepts: PMScreen  

Science Conference Proceedings (OSTI)

EPRI has been developing technologies to enable power generators to meet more stringent particulate matter (PM) emission requirements for units equipped with underperforming electrostatic precipitators (ESPs). PMScreen makes use of novel filter materials and the electrical charging supplied by the ESP to achieve supplemental PM capture at the ESP outlet at minimal pressure drop. This report summarizes results of slipstream proof-of-concept testing at a power plant site.

2009-03-16T23:59:59.000Z

35

Rugate Technology For Thermophotovoltaic (TPV) Applications: A New Approach To Near Perfect Filter Performance  

Science Conference Proceedings (OSTI)

Rugate filter technology is relatively unknown to the Solar PV? and the TPV community. The objective of this paper is to draw attention to Rugate filters as an enabling technology that may help to realize unprecedented conversion efficiencies in each respective field. Rugate filters are advanced optical interference filters with a continuously varied refractive index that changes periodically in the direction perpendicular to the film plane. The near noise free transmission and reflection quality of these filters

Ugur Ortabasi; Bertrand Bovard

2003-01-01T23:59:59.000Z

36

Bypassing the learning curve in permanent seed implants using state-of-the-art technology  

SciTech Connect

Purpose: The aim of this study was to demonstrate, based on clinical postplan dose distributions, that technology can be used efficiently to eliminate the learning curve associated with permanent seed implant planning and delivery. Methods and Materials: Dose distributions evaluated 30 days after the implant of the initial 22 consecutive patients treated with permanent seed implants at two institutions were studied. Institution 1 (I1) consisted of a new team, whereas institution 2 (I2) had performed more than 740 preplanned implantations over a 9-year period before the study. Both teams had adopted similar integrated systems based on three-dimensional (3D) transrectal ultrasonography, intraoperative dosimetry, and an automated seed delivery and needle retraction system (FIRST, Nucletron). Procedure time and dose volume histogram parameters such as D90, V100, V150, V200, and others were collected in the operating room and at 30 days postplan. Results: The average target coverage from the intraoperative plan (V100) was 99.4% for I1 and 99.9% for I2. D90, V150, and V200 were 191.4 Gy (196.3 Gy), 75.3% (73.0%), and 37.5% (34.1%) for I1 (I2) respectively. None of these parameters shows a significant difference between institutions. The postplan D90 was 151.2 Gy for I1 and 167.3 Gy for I2, well above the 140 Gy from the Stock et al. analysis, taking into account differences at planning, results in a p value of 0.0676. The procedure time required on average 174.4 min for I1 and 89 min for I2. The time was found to decrease with the increasing number of patients. Conclusion: State-of-the-art technology enables a new brachytherapy team to obtain excellent postplan dose distributions, similar to those achieved by an experienced team with proven long-term clinical results. The cost for bypassing the usual dosimetry learning curve is time, with increasing team experience resulting in shorter treatment times.

Beaulieu, Luc [Departement de Radio-oncologie, Centre Hospitalier Universitaire de Quebec, Hotel-Dieu de Quebec, Quebec, PQ (Canada)]. E-mail: beaulieu@phy.ulaval.ca; Evans, Dee-Ann Radford [Departments of Radiation Oncology and Medical Physics, Tom Baker Cancer Centre, Calgary, AB (Canada); Aubin, Sylviane [Departement de Radio-oncologie, Centre Hospitalier Universitaire de Quebec, Hotel-Dieu de Quebec, Quebec, PQ (Canada); Angyalfi, Steven [Departments of Radiation Oncology and Medical Physics, Tom Baker Cancer Centre, Calgary, AB (Canada); Husain, Siraj [Departments of Radiation Oncology and Medical Physics, Tom Baker Cancer Centre, Calgary, AB (Canada); Kay, Ian [Departments of Radiation Oncology and Medical Physics, Tom Baker Cancer Centre, Calgary, AB (Canada); Martin, Andre-Guy [Departement de Radio-oncologie, Centre Hospitalier Universitaire de Quebec, Hotel-Dieu de Quebec, Quebec, PQ (Canada); Varfalvy, Nicolas [Departement de Radio-oncologie, Centre Hospitalier Universitaire de Quebec, Hotel-Dieu de Quebec, Quebec, PQ (Canada); Vigneault, Eric [Departement de Radio-oncologie, Centre Hospitalier Universitaire de Quebec, Hotel-Dieu de Quebec, Quebec, PQ (Canada); Dunscombe, Peter [Departments of Radiation Oncology and Medical Physics, Tom Baker Cancer Centre, Calgary, AB (Canada)

2007-01-01T23:59:59.000Z

37

Available Technologies: Channelized Filter Inlets or Strippers for ...  

APPLICATIONS OF TECHNOLOGY: Formaldehyde measurement devices; Air pollution monitoring/industrial hygiene; Medical research, e.g., monitoring breath for biomarkers of ...

38

Performance-Based Technology Selection Filter description report. INEL Buried Waste Integrated Demonstration System Analysis project  

SciTech Connect

A formal methodology has been developed for identifying technology gaps and assessing innovative or postulated technologies for inclusion in proposed Buried Waste Integrated Demonstration (BWID) remediation systems. Called the Performance-Based Technology Selection Filter, the methodology provides a formalized selection process where technologies and systems are rated and assessments made based on performance measures, and regulatory and technical requirements. The results are auditable, and can be validated with field data. This analysis methodology will be applied to the remedial action of transuranic contaminated waste pits and trenches buried at the Idaho National Engineering Laboratory (INEL).

O`Brien, M.C.; Morrison, J.L.; Morneau, R.A.; Rudin, M.J.; Richardson, J.G.

1992-05-01T23:59:59.000Z

39

Technologies  

Technologies Materials. Aggregate Spray for Air Particulate; Actuators Made From Nanoporous Materials; Ceramic Filters; Energy Absorbing Material; Diode Arrays for ...

40

V-005: ModSecurity Multipart Message Parsing Security Bypass Vulnerability  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: ModSecurity Multipart Message Parsing Security Bypass 5: ModSecurity Multipart Message Parsing Security Bypass Vulnerability V-005: ModSecurity Multipart Message Parsing Security Bypass Vulnerability October 18, 2012 - 6:00am Addthis PROBLEM: ModSecurity Multipart Message Parsing Security Bypass Vulnerability PLATFORM: Modsecurity Versions prior to 2.70 ABSTRACT: SEC Consult has reported a vulnerability in ModSecurity, which can be exploited by malicious people to bypass certain security restrictions REFERENCE LINKS: SEC Consult Secunia Advisory SA49853 IMPACT ASSESSMENT: Medium DISCUSSION: The vulnerability is caused due to an error when parsing multipart requests and can be exploited to bypass certain filtering rules. IMPACT: Remote Security Bypass SOLUTION: Update to version 2.70. Addthis Related Articles V-017: Apache Tomcat Security Bypass and Denial of Service Vulnerabilities

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

New and Underutilized Technology: Air-side Economizers and Filters for Data Centers  

Energy.gov (U.S. Department of Energy (DOE))

The following information outlines key deployment considerations for air-side economizers and filters for data centers within the Federal sector.

42

Program on Technology Innovation: Evaluation of a Commercially Available Harmonic Filter  

Science Conference Proceedings (OSTI)

Emissions tests were conducted to analyze common and differential noise, harmonics, and current draw characteristics in the electrical systems of a typical household. A test setup was constructed to simulate the circuits of this typical household in order to determine how the STETZERiZER® Filters might affect the electric currents and voltages these circuits. Testing was performed in a frequency range of 3 kHz - 150 kHz to measure the effect of these filters on power draw and power quality, as ...

2013-10-04T23:59:59.000Z

43

Moving granular-bed filter development program, Option III: Development of moving granular-bed filter technology for multi-contaminant control. Task 14: Test plan; Topical report  

Science Conference Proceedings (OSTI)

An experimental test plan has been prepared for DOE/METC review and approval to develop a filter media suitable for multi-contaminant control in granular-bed filter (GBF) applications. The plan includes identification, development, and demonstration of methods for enhanced media morphology, chemical reactivity, and mechanical strength. The test plan includes media preparation methods, physical and chemical characterization methods for fresh and reacted media, media evaluation criteria, details of test and analytical equipment, and test matrix of the proposed media testing. A filter media composed of agglomerated limestone and clay was determined to be the best candidate for multi-contaminate control in GBF operation. The combined limestone/clay agglomerate has the potential to remove sulfur and alkali species, in addition to particulate, and possibly halogens and trace heavy metals from coal process streams.

Haas, J.C.; Olivo, C.A.; Wilson, K.B.

1994-04-01T23:59:59.000Z

44

Quick-change filter cartridge  

DOE Patents (OSTI)

A quick-change filter cartridge. In sampling systems for measurement of airborne materials, a filter element is introduced into the sampled airstream such that the aerosol constituents are removed and deposited on the filter. Fragile sampling media often require support in order to prevent rupture during sampling, and careful mounting and sealing to prevent misalignment, tearing, or creasing which would allow the sampled air to bypass the filter. Additionally, handling of filter elements may introduce cross-contamination or exposure of operators to toxic materials. Moreover, it is desirable to enable the preloading of filter media into quick-change cartridges in clean laboratory environments, thereby simplifying and expediting the filter-changing process in the field. The quick-change filter cartridge of the present invention permits the application of a variety of filter media in many types of instruments and may also be used in automated systems. The cartridge includes a base through which a vacuum can be applied to draw air through the filter medium which is located on a porous filter support and held there by means of a cap which forms an airtight seal with the base. The base is also adapted for receiving absorbing media so that both particulates and gas-phase samples may be trapped for investigation, the latter downstream of the aerosol filter.

Rodgers, John C. (Santa Fe, NM); McFarland, Andrew R. (College Station, TX); Ortiz, Carlos A. (Bryan, TX)

1995-01-01T23:59:59.000Z

45

Cordierite silicon nitride filters  

SciTech Connect

The objective of this project was to develop a silicon nitride based crossflow filter. This report summarizes the findings and results of the project. The project was phased with Phase I consisting of filter material development and crossflow filter design. Phase II involved filter manufacturing, filter testing under simulated conditions and reporting the results. In Phase I, Cordierite Silicon Nitride (CSN) was developed and tested for permeability and strength. Target values for each of these parameters were established early in the program. The values were met by the material development effort in Phase I. The crossflow filter design effort proceeded by developing a macroscopic design based on required surface area and estimated stresses. Then the thermal and pressure stresses were estimated using finite element analysis. In Phase II of this program, the filter manufacturing technique was developed, and the manufactured filters were tested. The technique developed involved press-bonding extruded tiles to form a filter, producing a monolithic filter after sintering. Filters manufactured using this technique were tested at Acurex and at the Westinghouse Science and Technology Center. The filters did not delaminate during testing and operated and high collection efficiency and good cleanability. Further development in areas of sintering and filter design is recommended.

Sawyer, J.; Buchan, B. (Acurex Environmental Corp., Mountain View, CA (United States)); Duiven, R.; Berger, M. (Aerotherm Corp., Mountain View, CA (United States)); Cleveland, J.; Ferri, J. (GTE Products Corp., Towanda, PA (United States))

1992-02-01T23:59:59.000Z

46

By-pass valve  

Science Conference Proceedings (OSTI)

An improved by-pass valve (1) for use in an automobile exhaust system (Es) comprises an air inlet (7) connected to an air pump (Ap), first and second air outlets (15,23) respectively connected to first and second portions (P1,p2) of a catalytic converter (Cc) and a third outlet (33) through which air is dumped to atmosphere. Air is directed from the inlet to the first outlet when engine temperature is less than a predetermined value and from the inlet to the second outlet when engine temperature reaches the predetermined value. A first and normally closed valve (81) is intermediate the air inlet and the first and second outlets and a second and normally open valve (83) is intermediate the air inlet and the third outlet. The first valve is opened and the second valve closed when engine vacuum exceeds a predetermined level so air flows to either the first or second outlet. The second valve is reopened whenever the outlet to which air is directed is blocked so air is dumped to atmosphere. To accomplish this, the first valve is mounted on the first section (111) of a split shaft (109) and the second valve is mounted on a second shaft section (113). The sections are movable in unison to open the first valve, but the second section is movable relative to the first section when a blockage occurs to reopen the second valve.

Williamson, R.E.

1981-01-06T23:59:59.000Z

47

Cermet Filters  

INL’s cermet filter is self-cleaning and reduces pollutant emissions, e.g. NOx in vehicles, which can be harmful in heavier duty diesel trucks. This filter lasts far longer compared to other filters because it is self-cleaning, which avoids plugging.

48

Granular filter  

SciTech Connect

The invention described and claimed in this application relates to granular filters and, more particularly, to continuously regenerate granular filters operatable at high temperature and pressure which are particularly suited for cleaning gas used to operate a gas turbine. The filter is of relatively small size and by nature of its operation couples high filtering efficiency with maximum practicable protection to downstream equipment from ash from combustion of the solid fuel and from small particle of the filtering medium entrained in the flowing gas, which would case deposit buildup and erosion to the turbine blades.

Lear, D.E. Jr; Schmid, A.H.; Wigton, H.F.H.

1977-07-12T23:59:59.000Z

49

Method for optimizing output in ultrashort-pulse multipass laser amplifiers with selective use of a spectral filter  

DOE Patents (OSTI)

A method for optimizing multipass laser amplifier output utilizes a spectral filter in early passes but not in later passes. The pulses shift position slightly for each pass through the amplifier, and the filter is placed such that early passes intersect the filter while later passes bypass it. The filter position may be adjust offline in order to adjust the number of passes in each category. The filter may be optimized for use in a cryogenic amplifier.

Backus, Sterling J. (Erie, CO); Kapteyn, Henry C. (Boulder, CO)

2007-07-10T23:59:59.000Z

50

RTD bypass system elimination at Virgil C. Summer Station  

SciTech Connect

This paper reports on the resistance temperature detector (RTD) bypass system removal project which was a high dose job, a large capital project and had the potential to be a critical path item. The purpose of this project was to remove the existing direct immersion temperature detection system requiring primary coolant bypass piping, and replace it with the latest in RTD technology. These are well-mounted RTDs, which are more reliable and require much less personnel radiation dose during maintenance. As a result of the project, the source term at V.C. Summer was significantly reduced and dose rates inside the loop cavities were decreased by a factor of seven on average. This has resulted in lower cumulative exposure for reactor coolant pump, steam generator, and general maintenance activities.

Mothena, P.A. (South Carolina Electric and Gas Co. (US))

1992-02-01T23:59:59.000Z

51

Filtering apparatus  

DOE Patents (OSTI)

A vertical vessel having a lower inlet and an upper outlet enclosure separated by a main horizontal tube sheet. The inlet enclosure receives the flue gas from a boiler of a power system and the outlet enclosure supplies cleaned gas to the turbines. The inlet enclosure contains a plurality of particulate-removing clusters, each having a plurality of filter units. Each filter unit includes a filter clean-gas chamber defined by a plate and a perforated auxiliary tube sheet with filter tubes suspended from each tube sheet and a tube connected to each chamber for passing cleaned gas to the outlet enclosure. The clusters are suspended from the main tube sheet with their filter units extending vertically and the filter tubes passing through the tube sheet and opening in the outlet enclosure. The flue gas is circulated about the outside surfaces of the filter tubes and the particulate is absorbed in the pores of the filter tubes. Pulses to clean the filter tubes are passed through their inner holes through tubes free of bends which are aligned with the tubes that pass the clean gas.

Haldipur, Gaurang B. (Monroeville, PA); Dilmore, William J. (Murrysville, PA)

1992-01-01T23:59:59.000Z

52

Filtering apparatus  

DOE Patents (OSTI)

A vertical vessel is described having a lower inlet and an upper outlet enclosure separated by a main horizontal tube sheet. The inlet enclosure receives the flue gas from a boiler of a power system and the outlet enclosure supplies cleaned gas to the turbines. The inlet enclosure contains a plurality of particulate-removing clusters, each having a plurality of filter units. Each filter unit includes a filter clean-gas chamber defined by a plate and a perforated auxiliary tube sheet with filter tubes suspended from each tube sheet and a tube connected to each chamber for passing cleaned gas to the outlet enclosure. The clusters are suspended from the main tube sheet with their filter units extending vertically and the filter tubes passing through the tube sheet and opening in the outlet enclosure. The flue gas is circulated about the outside surfaces of the filter tubes and the particulate is absorbed in the pores of the filter tubes. Pulses to clean the filter tubes are passed through their inner holes through tubes free of bends which are aligned with the tubes that pass the clean gas. 18 figs.

Haldipur, G.B.; Dilmore, W.J.

1992-09-01T23:59:59.000Z

53

High-speed hardware efficient FIR compensation filter for Delta-Sigma modulator analog-to-digital converter in 0.13 µm CMOS technology  

Science Conference Proceedings (OSTI)

A high-speed hardware efficient 41-tap, 15-bit word length Finite Impulse Response (FIR) Compensation Filter has been designed as a component in a Delta-Sigma Modulator (DSM) Analog-to-Digital Converter (ADC). The filter is targeted for high-throughput ... Keywords: ADC, FIR filter, compensation, delta-sigma, high-speed

Boon-Siang Cheah; Ray Siferd

2005-11-01T23:59:59.000Z

54

Development of improved methods for locating large areas of bypassed oil in Louisiana. Final report  

SciTech Connect

The primary objective of the project was to develop a predictive method for locating Pockets of bypassed mobile oil and estimating the volume of this resource. A secondary objective of the project was to transfer the learned technology to small independent operators who drill a majority of the domestic wells but lack access to a research staff. Another objective was to develop a format for compiling data on Louisiana reservoirs in a form that can be used by government and industry to evaluate the resource and plan future activities. The format developed will be demonstrated using data compiled in the bypassed oil study for selected reservoirs. The project was being funded over a three-year period and was jointly funded by the DOE and the state of Louisiana. The objectives of the project were accomplished using an interdisciplinary approach which included the disciplines of engineering, geology, and computer science. The work was organized into the following major tasks: Selection of reservoirs for study of bypassed oil potential; development of improved reservoir simulator for bypassed oil prospecting; an interdisciplinary reservoir characterization study of Louisiana reservoirs; active modelling of bypassed oil for three Louisiana reservoirs; and technology transfer activities.

Bourgoyne, A.T. Jr.; Kimbrell, C.

1994-07-01T23:59:59.000Z

55

Exhaust gas bypass valve control for thermoelectric generator  

DOE Patents (OSTI)

A method of controlling engine exhaust flow through at least one of an exhaust bypass and a thermoelectric device via a bypass valve is provided. The method includes: determining a mass flow of exhaust exiting an engine; determining a desired exhaust pressure based on the mass flow of exhaust; comparing the desired exhaust pressure to a determined exhaust pressure; and determining a bypass valve control value based on the comparing, wherein the bypass valve control value is used to control the bypass valve.

Reynolds, Michael G; Yang, Jihui; Meisner, Greogry P.; Stabler, Francis R.; De Bock, Hendrik Pieter (Peter) Jacobus; Anderson, Todd Alan

2012-09-04T23:59:59.000Z

56

Bypass diode for a solar cell  

SciTech Connect

Bypass diodes for solar cells are described. In one embodiment, a bypass diode for a solar cell includes a substrate of the solar cell. A first conductive region is disposed above the substrate, the first conductive region of a first conductivity type. A second conductive region is disposed on the first conductive region, the second conductive region of a second conductivity type opposite the first conductivity type.

Rim, Seung Bum (Palo Alto, CA); Kim, Taeseok (San Jose, CA); Smith, David D. (Campbell, CA); Cousins, Peter J. (Menlo Park, CA)

2012-03-13T23:59:59.000Z

57

Specific filter designs for PFBC  

SciTech Connect

Bubbling bed PFBC technology is currently being demonstrated at commercial scale. Economic and performance improvements in these first generation type PFBC plants can be realized with the application of hot gas particulate filters. Both the secondary cyclone(s) and stack gas ESP(s) could be eliminated saving costs and providing lower system pressure losses. The cleaner gas (basically ash free) provided with the hot gas filter, also permits a wider selection of gas turbines with potentially higher performance. For these bubbling bed PFBC applications, the hot gas filter must operate at temperatures of 1580{degree}F and system pressures of 175 psia (conditions typical of the Tidd PFBC plant). Inlet dust loadings to the filter are estimated to be about 500 to 1000 ppm with mass mean particle diameters ranging from 1.5 to 3 {mu}m. For commercial applications typical of the 70 MW{sub e} Tidd PFBC demonstration unit, the filter must treat up to 56,600 acfm of gas flow. Scaleup of this design to about 320 MW{sub e} would require filtering over 160,000 acfm gas flow. For these commercial scale systems, multiple filter vessels are required. Thus, the filter design should be modular for scaling. An alternative to the bubbling bed PFBC is the circulating bed concept. In this process the hot gas filter will in general be exposed to higher operating temperatures (1650{degree}F) and significantly higher (factor of 10 or more) particle loading.

Lippert, T.E.; Bruck, G.J.; Newby, R.A.; Smeltzer, E.E.

1993-09-01T23:59:59.000Z

58

Ethernet filter  

DOE Patents (OSTI)

This invention is comprised of an apparatus and method that prevents access to unauthorized data in a local area network, such as Ethernet, in which information is transmitted from a transceiver to at least one workstation. Encoded data packets transmitted from the transceiver are filtered by splitting the packet into two signals. One signal contains the data that was transmitted, while the other signal contains tainted data. The filter determines whether a workstation is authorized to access the data, and then delivers either the tainted data to unauthorized workstations, or the data that was transmitted to authorized workstations.

Charney, E.J.; Tanzella, A.J.; Wujcik, J.G.

1990-11-09T23:59:59.000Z

59

Turbine protection system for bypass operation  

SciTech Connect

In a steam turbine installation having a high pressure turbine, a steam generator is described for providing steam to the turbine, at least a lower pressure turbine, a reheater in the steam path between the high and lower pressure turbines, and a steam bypass path for bypassing the turbines, the high pressure turbine having a one-way check valve in its output steam line to prevent bypass steam from entering its output. The improvement described here consists of: (A) a second bypass path for passing steam around the high pressure turbine; (B) the second bypass path including, (i) steam jet compressor means including two input sections and an output section, with one input section being connected to the high pressure turbine output, the other input section being connected to receive steam from the steam generator and the output section being connected to the input of the reheater, (ii) valving means for controlling the steam supply from the steam generator to the steam jet compressor means; and (C) control means responsive to an output condition at the high pressure turbine output for controlling the valving means.

Silvestri, G.J. Jr.

1986-03-18T23:59:59.000Z

60

PURADYN Oil Bypass Filtration System Evaluation Test Plan  

NLE Websites -- All DOE Office Websites (Extended Search)

& Infrastructure Department PURADYN OIL BYPASS FILTRATION SYSTEM EVALUATION TEST PLAN October 2002 Reviewed: INEEL Fleet Maintenance Supervisor (Thomas) Date Reviewed:...

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

In-place HEPA filter penetration test  

SciTech Connect

We have demonstrated the feasibility of conducting penetration tests on high efficiency particulate air (HEPA) filters as installed in nuclear ventilation systems. The in-place penetration test, which is designed to yield equivalent penetration measurements as the standard DOP efficiency test, is based on measuring the aerosol penetration of the filter installation as a function of particle size using a portable laser particle counter. This in-place penetration test is compared to the current in-place leak test using light scattering photometers for single HEPA filter installations and for HEPA filter plenums using the shroud method. Test results show the in-place penetration test is more sensitive than the in-place leak test, has a similar operating procedure, but takes longer to conduct. Additional tests are required to confirm that the in-place penetration test yields identical results as the standard dioctyl phthalate (DOP) penetration test for HEPA filters with controlled leaks in the filter and gasket and duct by-pass leaks. Further development of the procedure is also required to reduce the test time before the in- place penetration test is practical.

Bergman, W.; Wilson, kK.; Elliott, J.; Bettencourt, B.; Slawski, J.W.

1997-01-01T23:59:59.000Z

62

Bypass apparatus and method for series connected energy storage devices  

DOE Patents (OSTI)

A bypass apparatus and method for series connected energy storage devices. Each of the energy storage devices coupled to a common series connection has an associated bypass unit connected thereto in parallel. A current bypass unit includes a sensor which is coupled in parallel with an associated energy storage device or cell and senses an energy parameter indicative of an energy state of the cell, such as cell voltage. A bypass switch is coupled in parallel with the energy storage cell and operable between a non-activated state and an activated state. The bypass switch, when in the non-activated state, is substantially non-conductive with respect to current passing through the energy storage cell and, when in the activated state, provides a bypass current path for passing current to the series connection so as to bypass the associated cell. A controller controls activation of the bypass switch in response to the voltage of the cell deviating from a pre-established voltage setpoint. The controller may be included within the bypass unit or be disposed on a control platform external to the bypass unit. The bypass switch may, when activated, establish a permanent or a temporary bypass current path.

Rouillard, Jean (Saint-Luc, CA); Comte, Christophe (Montreal, CA); Daigle, Dominik (St-Hyacinthe, CA)

2000-01-01T23:59:59.000Z

63

Ceramic HEPA Filter Program  

SciTech Connect

Potential benefits of ceramic filters in nuclear facilities: (1) Short term benefit for DOE, NRC, and industry - (a) CalPoly HTTU provides unique testing capability to answer questions for DOE - High temperature testing of materials, components, filter, (b) Several DNFSB correspondences and presentations by DNFSB members have highlighted the need for HEPA filter R and D - DNFSB Recommendation 2009-2 highlighted a nuclear facility response to an evaluation basis earthquake followed by a fire (aka shake-n-bake) and CalPoly has capability for a shake-n-bake test; (2) Intermediate term benefit for DOE and industry - (a) Filtration for specialty applications, e.g., explosive applications at Nevada, (b) Spin-off technologies applicable to other commercial industries; and (3) Long term benefit for DOE, NRC, and industry - (a) Across industry, strong desire for better performance filter, (b) Engineering solution to safety problem will improve facility safety and decrease dependence on associated support systems, (c) Large potential life-cycle cost savings, and (d) Facilitates development and deployment of LLNL process innovations to allow continuous ventilation system operation during a fire.

Mitchell, M A; Bergman, W; Haslam, J; Brown, E P; Sawyer, S; Beaulieu, R; Althouse, P; Meike, A

2012-04-30T23:59:59.000Z

64

Cordierite silicon nitride filters. Final report  

SciTech Connect

The objective of this project was to develop a silicon nitride based crossflow filter. This report summarizes the findings and results of the project. The project was phased with Phase I consisting of filter material development and crossflow filter design. Phase II involved filter manufacturing, filter testing under simulated conditions and reporting the results. In Phase I, Cordierite Silicon Nitride (CSN) was developed and tested for permeability and strength. Target values for each of these parameters were established early in the program. The values were met by the material development effort in Phase I. The crossflow filter design effort proceeded by developing a macroscopic design based on required surface area and estimated stresses. Then the thermal and pressure stresses were estimated using finite element analysis. In Phase II of this program, the filter manufacturing technique was developed, and the manufactured filters were tested. The technique developed involved press-bonding extruded tiles to form a filter, producing a monolithic filter after sintering. Filters manufactured using this technique were tested at Acurex and at the Westinghouse Science and Technology Center. The filters did not delaminate during testing and operated and high collection efficiency and good cleanability. Further development in areas of sintering and filter design is recommended.

Sawyer, J.; Buchan, B. [Acurex Environmental Corp., Mountain View, CA (United States); Duiven, R.; Berger, M. [Aerotherm Corp., Mountain View, CA (United States); Cleveland, J.; Ferri, J. [GTE Products Corp., Towanda, PA (United States)

1992-02-01T23:59:59.000Z

65

Technologies  

Science & Technology. Weapons & Complex Integration. News Center. News Center. Around the Lab. Contacts. For Reporters. Livermore Lab Report. ...

66

Technologies  

Technologies Energy. Advanced Carbon Aerogels for Energy Applications; Distributed Automated Demand Response; Electrostatic Generator/Motor; Modular Electromechanical ...

67

Technologies  

Technologies Energy, Utilities, & Power Systems. Advanced Carbon Aerogels for Energy Applications; Distributed Automated Demand Response; Electrostatic Generator/Motor

68

Technologies  

Technologies Research Tools. Cell-Free Assembly of NanoLipoprotein Particles; Chemical Prism; Lawrence Livermore Microbial Detection Array (LLMDA) ...

69

Hoover Dam Bypass Project Phase II  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

DOE/EA-1478 DOE/EA-1478 ENVIRONMENTAL ASSESSMENT Western' s Hoover Dam Bypass Project Phase II (Double-Circuiting a Portion of the Hoover-Mead #5 and #7 230-kV Transmission Lines with the Henderson-Mead #1 230-kV Transmission Line, Clark County, Nevada) Prepared for: U.S. Department of Energy Western Area Power Administration 615 S. 43 rd Avenue Phoenix, Arizona 85009 Prepared by: Transcon Environmental 3740 East Southern Avenue, Suite 218 Mesa, Arizona 85206 (480) 807-0095 October 2003 Western Area Power Administration Hoover Dam Bypass Project Phase II page i Environmental Assessment TABLE OF CONTENTS 1.0 INTRODUCTION ............................................................................................................................1 1.1 Background..................................................................................................................................1

70

Condensate Filter Demineralizer Performance Improvement Program  

Science Conference Proceedings (OSTI)

Upgrading condensate filter demineralizer (CFD) performance poses a complex, challenging utility task. This report summarizes the major factors that impact CFD performance and defines a comprehensive improvement program. In specific, the report discusses hardware, filter media, and operating practices, describing each area in terms of the underlying technology, approach to optimization, and utility experience.

1997-07-21T23:59:59.000Z

71

Technologies  

High Performance Computing (HPC) Technologies; Industrial Partnerships Office P.O. Box 808, L-795 Livermore, CA 94551 Phone: (925) 422-6416 Fax: (925) ...

72

U-246: Tigase XMPP Dialback Protection Bypass Vulnerability | Department of  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6: Tigase XMPP Dialback Protection Bypass Vulnerability 6: Tigase XMPP Dialback Protection Bypass Vulnerability U-246: Tigase XMPP Dialback Protection Bypass Vulnerability August 28, 2012 - 7:00am Addthis PROBLEM: Tigase XMPP Dialback Protection Bypass Vulnerability PLATFORM: Tigase 5.x ABSTRACT: A vulnerability has been reported in Tigase, which can be exploited by malicious people to bypass certain security restrictions. reference LINKS: XMPP Standards Foundation Secunia Advisory SA50362 tigase.org CVE-2012-4670 IMPACT ASSESSMENT: Medium Discussion: The vulnerability is caused due to an error within the XMPP protocol implementation, which does not properly verify the "Verify Response" and "Authorization Response" messages. This can be exploited to spoof a domain and bypass the Dialback protection.

73

An improved visualization of diesel particulate filter/  

E-Print Network (OSTI)

The prevalence of diesel particulate filters (DPF) is increasing as emissions standards worldwide evolve to match current technologies. Since the first application of DPFs in the 1980's, PM trapping effectiveness has ...

Boehm, Kevin (Kevin W.)

2011-01-01T23:59:59.000Z

74

Filter systems for IGCC applications  

SciTech Connect

The objectives of this program were to identify metallic filter medium to be utilized in the Integrated Gasification Combined Cycle process (IGCC). In IGCC processes utilizing high efficiency desulfurizing technology, the traditional corrosion attack, sulfidation, is minimized so that metallic filters are viable alternatives over ceramic filters. Tampa Electric Company`s Polk Power Station is being developed to demonstrate Integrated Gasification Combined Cycle technology. The Pall Gas Solid Separation (GSS) System is a self cleaning filtration system designed to remove virtually all particulate matter from gas streams. The heart of the system is the filter medium used to collect the particles on the filter surface. The medium`s filtration efficiency, uniformity, permeability, voids volume, and surface characteristics are all important to establishing a permeable permanent cake. In-house laboratory blowback tests, using representative full scale system particulate, were used to confirm the medium selection for this project. Test elements constructed from six alloys were supplied for exposure tests: PSS 310SC (modified 310S alloy); PSS 310SC heat treated; PSS 310SC-high Cr; PSS 310SC-high Cr heat treated; PSS Hastelloy X; and PSS Hastelloy X heat treated.

Bevan, S.; Gieger, R.; Sobel, N.; Johnson, D.

1995-11-01T23:59:59.000Z

75

FACTORS AFFECTING RURAL KENTUCKY PATIENTS HOSPITAL CHOICE AND BYPASS BEHAVIOR.  

E-Print Network (OSTI)

??This study examines the underutilization of rural hospitals in Kentucky. The authors study hospital and patient characteristics to determine why and how rural patients bypass… (more)

He, Xiao

2011-01-01T23:59:59.000Z

76

V-237: TYPO3 Security Bypass Vulnerabilities | Department of...  

NLE Websites -- All DOE Office Websites (Extended Search)

SA54717 Security Focus ID 62257 IMPACT ASSESSMENT: Medium DISCUSSION: 1) Some errors when handling file actions can be exploited to bypass file action permission restrictions and...

77

V-162: Apache Struts "ParameterInterceptor" Security Bypass Vulnerabil...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

arbitrary methods, bypassing Struts and OGNL library protections. 2. Any unsanitized String variable exposed by an action and have it evaluated as an OGNL expression to enable...

78

Heat exchanger bypass system for an absorption refrigeration system  

DOE Patents (OSTI)

A heat exchanger bypass system for an absorption refrigeration system is disclosed. The bypass system operates to pass strong solution from the generator around the heat exchanger to the absorber of the absorption refrigeration system when strong solution builds up in the generator above a selected level indicative of solidification of strong solution in the heat exchanger or other such blockage. The bypass system includes a bypass line with a gooseneck located in the generator for controlling flow of strong solution into the bypass line and for preventing refrigerant vapor in the generator from entering the bypass line during normal operation of the refrigeration system. Also, the bypass line includes a trap section filled with liquid for providing a barrier to maintain the normal pressure difference between the generator and the absorber even when the gooseneck of the bypass line is exposed to refrigerant vapor in the generator. Strong solution, which may accumulate in the trap section of the bypass line, is diluted, to prevent solidification, by supplying weak solution to the trap section from a purge system for the absorption refrigeration system.

Reimann, Robert C. (Lafayette, NY)

1984-01-01T23:59:59.000Z

79

Technolog  

NLE Websites -- All DOE Office Websites (Extended Search)

Research in Research in Science and Technolog y Sandia pushes frontiers of knowledge to meet the nation's needs, today and tomorrow Sandia National Laboratories' fundamental science and technology research leads to greater understanding of how and why things work and is intrinsic to technological advances. Basic research that challenges scientific assumptions enables the nation to push scientific boundaries. Innovations and breakthroughs produced at Sandia allow it to tackle critical issues, from maintaining the safety, security and effectiveness of the nation's nuclear weapons and preventing domestic and interna- tional terrorism to finding innovative clean energy solutions, develop- ing cutting-edge nanotechnology and moving the latest advances to the marketplace. Sandia's expertise includes:

80

Technology  

NLE Websites -- All DOE Office Websites (Extended Search)

Technology Computers and the internet play an increasingly larger role in the lives of students. In this activity, students must use various web sites to locate specific pieces of...

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

FILTER COMPONENT ASSESSMENT--CERAMIC CANDLES--  

SciTech Connect

Efforts at Siemens Westinghouse Power Corporation (SWPC) have been focused on development of hot gas filter systems as an enabling technology for advanced coal and biomass-based gas turbine power generation applications. SWPC has been actively involved in the development of advanced filter materials and component configuration, has participated in numerous surveillance programs characterizing the material properties and microstructure of field tested filter elements, and has undertaken extended, accelerated filter life testing programs. This report summarizes the results of SWPC's filter component assessment efforts, identifying the performance and stability of porous monolithic, fiber reinforced, and filament wound ceramic hot gas candle filters, potentially for {ge}3 years of viable pressurized fluidized-bed combustion (PFBC) service operating life.

M.A. Alvin

2004-04-23T23:59:59.000Z

82

Hepa filter dissolution process  

DOE Patents (OSTI)

A process for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal.

Brewer, Ken N. (Arco, ID); Murphy, James A. (Idaho Falls, ID)

1994-01-01T23:59:59.000Z

83

Recirculating electric air filter  

DOE Patents (OSTI)

An electric air filter cartridge has a cylindrical inner high voltage eleode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

Bergman, Werner (Pleasanton, CA)

1986-01-01T23:59:59.000Z

84

HEPA filter dissolution process  

DOE Patents (OSTI)

A process is described for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal. 4 figures.

Brewer, K.N.; Murphy, J.A.

1994-02-22T23:59:59.000Z

85

HEPA filter dissolution process  

DOE Patents (OSTI)

This invention is comprised of a process for dissolution of spent high efficiency particulate air (HEPA) filters and then combining the complexed filter solution with other radioactive wastes prior to calcining the mixed and blended waste feed. The process is an alternate to a prior method of acid leaching the spent filters which is an inefficient method of treating spent HEPA filters for disposal.

Brewer, K.N.; Murphy, J.A.

1992-12-31T23:59:59.000Z

86

Bypass aware instruction scheduling for register file power reduction  

Science Conference Proceedings (OSTI)

Since register files suffer from some of the highest power densities within processors, designers have investigated several architectural strategies for register file power reduction, including "On Demand RF Read" where the register file is read only ... Keywords: architecture-sensitive compiler, bypass-sensitive, forwarding paths, operation table, power consumption, processor bypasses, register file, reservation table

Sanghyun Park; Aviral Shrivastava; Nikil Dutt; Alex Nicolau; Yunheung Paek; Eugene Earlie

2006-07-01T23:59:59.000Z

87

T-646: Debian fex authentication bypass | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6: Debian fex authentication bypass 6: Debian fex authentication bypass T-646: Debian fex authentication bypass June 14, 2011 - 3:45pm Addthis PROBLEM: The vulnerability is caused due to the application not properly verifying the existence of "auth-ID" when uploading files and can be exploited to bypass the authentication mechanism. PLATFORM: Debian fex ABSTRACT: Debian security discovered that fex, a web service for transferring very large, files, is not properly validating authentication IDs. While the service properly validates existing authentication IDs, an attacker who is not specifying any authentication ID at all, can bypass the authentication procedure. reference LINKS: DSA-2259-1 fex Secunia Advisory SA44940 Debian Security Advisory DSA-2259-1 fex-20110610.tar Vulnerability Report: Debian GNU/Linux 6.0

88

T-674: Drupal Secure Password Hashes Module Security Bypass Vulnerability |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

74: Drupal Secure Password Hashes Module Security Bypass 74: Drupal Secure Password Hashes Module Security Bypass Vulnerability T-674: Drupal Secure Password Hashes Module Security Bypass Vulnerability July 22, 2011 - 3:00pm Addthis PROBLEM: Drupal Secure Password Hashes Module Security Bypass Vulnerability PLATFORM: Drupal Secure Password Hashes 6.X-1.0 Drupal Secure Password Hashes 5.X-1.4 ABSTRACT: The Secure Password Hashes module for Drupal is prone to a security-bypass vulnerability. reference LINKS: Drupal Homepage SA-CONTRIB-2011-026 - Secure Password Hashes (phpass) - Multiple Vulnerabilities IMPACT ASSESSMENT: Medium Discussion: This module uses the PHPass hashing library to try to store users hashed passwords securely. The module sets a fixed string for the 'pass' column in the {users} database column but does not replace the pass attribute of the account

89

V-237: TYPO3 Security Bypass Vulnerabilities | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

V-237: TYPO3 Security Bypass Vulnerabilities V-237: TYPO3 Security Bypass Vulnerabilities V-237: TYPO3 Security Bypass Vulnerabilities September 9, 2013 - 6:00am Addthis PROBLEM: Some vulnerabilities have been reported in TYPO3 PLATFORM: TYPO3 6.x ABSTRACT: TYPO3 comes with the possibility to restrict editors to certain file actions (copy, delete, move etc.) and to restrict these actions to be performed in certain locations REFERENCE LINKS: Secunia Advisory SA54717 Security Focus ID 62257 IMPACT ASSESSMENT: Medium DISCUSSION: 1) Some errors when handling file actions can be exploited to bypass file action permission restrictions and e.g. create or read arbitrary files within or outside the webroot. 2) An error when validating file names within the file renaming functionality can be exploited to bypass the denied file extensions check

90

ELECTROSTATICALLY ENHANCED BARRIER FILTER COLLECTION  

SciTech Connect

This work was performed through the University of North Dakota (UND) Chemical Engineering Department with assistance from UND's Energy & Environmental Research Center. This research was undertaken in response to the U.S. Department of Energy Federal Technology Center Program Solicitation No. DE-PS26-99FT40479, Support of Advanced Coal Research at U.S. Universities and Colleges. Specifically, this research was in support of the UCR Core Program and addressees Topic 1, Improved Hot-Gas Contaminant and Particulate Removal Techniques, introducing an advanced design for particulate removal. Integrated gasification combined cycle (IGCC) offers the potential for very high efficiency and clean electric generation. In IGCC, the product gas from the gasifier needs to be cleaned of particulate matter to avoid erosion and high-temperature corrosion difficulties arising with the turbine blades. Current methods involve cooling the gases to {approx}100 C to condense alkalis and remove sulfur and particulates using conventional scrubber technology. This ''cool'' gas is then directed to a turbine for electric generation. While IGCC has the potential to reach efficiencies of over 50%, the current need to cool the product gas for cleaning prior to firing it in a turbine is keeping IGCC from reaching its full potential. The objective of the current project was to develop a highly reliable particulate collector system that can meet the most stringent turbine requirements and emission standards, can operate at temperatures above 1500 F, is applicable for use with all U.S. coals, is compatible with various sorbent injection schemes for sulfur and alkali control, can be integrated into a variety of configurations for both pressurized gasification and combustion, increases allowable face velocity to reduce filter system capital cost, and is cost-competitive with existing technologies. The collector being developed is a new concept in particulate control called electrostatically enhanced barrier filter collection (EBFC). This concept combines electrostatic precipitation (ESP) with candle filters in a single unit. Similar technology has been recently proven on a commercial scale for atmospheric applications, but needed to be tested at high temperatures and pressures. The synergy obtained by combining the two control technologies into a single system should actually reduce filter system capital and operating costs and make the system more reliable. More specifically, the ESP is expected to significantly reduce candle filter load and also to limit ash reintrainment, allowing for full recovery of baseline pressure drop during backpulsing of the filters.

John Erjavec; Michael D. Mann; Ryan Z. Knutson; Michael L. Swanson; Michael E. Collings

2003-06-01T23:59:59.000Z

91

ARRANGEMENT FOR REPLACING FILTERS  

DOE Patents (OSTI)

An improved filtered air exhaust system which may be continually operated during the replacement of the filters without the escape of unfiltered air is described. This is accomplished by hermetically sealing the box like filter containers in a rectangular tunnel with neoprene covered sponge rubber sealing rings coated with a silicone impregnated pneumatic grease. The tunnel through which the filters are pushed is normal to the exhaust air duct. A number of unused filters are in line behind the filters in use, and are moved by a hydraulic ram so that a fresh filter is positioned in the air duct. The used filter is pushed into a waiting receptacle and is suitably disposed. This device permits a rapid and safe replacement of a radiation contaminated filter without interruption to the normal flow of exhaust air.

Blomgren, R.A.; Bohlin, N.J.C.

1957-08-27T23:59:59.000Z

92

Rigid porous filter  

DOE Patents (OSTI)

The present invention involves a porous rigid filter including a plurality of concentric filtration elements having internal flow passages and forming external flow passages there between. The present invention also involves a pressure vessel containing the filter for the removal of particulates from high pressure particulate containing gases, and further involves a method for using the filter to remove such particulates. The present filter has the advantage of requiring fewer filter elements due to the high surface area-to-volume ratio provided by the filter, requires a reduced pressure vessel size, and exhibits enhanced mechanical design properties, improved cleaning properties, configuration options, modularity and ease of fabrication.

Chiang, Ta-Kuan (Morgantown, WV); Straub, Douglas L. (Morgantown, WV); Dennis, Richard A. (Morgantown, WV)

2000-01-01T23:59:59.000Z

93

Filter type gas sampler with filter consolidation  

DOE Patents (OSTI)

Disclosed is an apparatus for automatically consolidating a filter or, more specifically, an apparatus for drawing a volume of gas through a plurality of sections of a filter, whereafter the sections are subsequently combined for the purpose of simultaneously interrogating the sections to detect the presence of a contaminant.

Miley, Harry S. (219 Rockwood Dr., Richland, WA 99352); Thompson, Robert C. (5313 Phoebe La., West Richland, WA 99352); Hubbard, Charles W. (1900 Stevens, Apt. 526, Richland, WA 99352); Perkins, Richard W. (1413 Sunset, Richland, WA 99352)

1997-01-01T23:59:59.000Z

94

HEPA Filter Vulnerability Assessment  

SciTech Connect

This assessment of High Efficiency Particulate Air (HEPA) filter vulnerability was requested by the USDOE Office of River Protection (ORP) to satisfy a DOE-HQ directive to evaluate the effect of filter degradation on the facility authorization basis assumptions. Within the scope of this assessment are ventilation system HEPA filters that are classified as Safety-Class (SC) or Safety-Significant (SS) components that perform an accident mitigation function. The objective of the assessment is to verify whether HEPA filters that perform a safety function during an accident are likely to perform as intended to limit release of hazardous or radioactive materials, considering factors that could degrade the filters. Filter degradation factors considered include aging, wetting of filters, exposure to high temperature, exposure to corrosive or reactive chemicals, and exposure to radiation. Screening and evaluation criteria were developed by a site-wide group of HVAC engineers and HEPA filter experts from published empirical data. For River Protection Project (RPP) filters, the only degradation factor that exceeded the screening threshold was for filter aging. Subsequent evaluation of the effect of filter aging on the filter strength was conducted, and the results were compared with required performance to meet the conditions assumed in the RPP Authorization Basis (AB). It was found that the reduction in filter strength due to aging does not affect the filter performance requirements as specified in the AB. A portion of the HEPA filter vulnerability assessment is being conducted by the ORP and is not part of the scope of this study. The ORP is conducting an assessment of the existing policies and programs relating to maintenance, testing, and change-out of HEPA filters used for SC/SS service. This document presents the results of a HEPA filter vulnerability assessment conducted for the River protection project as requested by the DOE Office of River Protection.

GUSTAVSON, R.D.

2000-05-11T23:59:59.000Z

95

Fail Save Shut Off Valve for Filtering Systems Employing Candle Filters  

NLE Websites -- All DOE Office Websites (Extended Search)

Fail Save Shut Off Fail Save Shut Off Valve for Filtering Systems Employing Candle Filters Opportunity The Department of Energy's National Energy Technology Laboratory (NETL) is seeking licensing partners interested in implementing United States Patent Number 6,981,516 entitled "Fail save shut off valve for filtering systems employing candle filters." Disclosed in this patent is a novel fail save shut off valve system that allows fluid flow during normal operational conditions, but prevents the flow of fluids in the event of system failure upstream that causes over- pressurization. It is particularly well suited for use in conjunction with hot gas filtering systems, which utilize ceramic candle filters. Used in such a hot gas system, the fail save valve stops the flow

96

V-106: Citrix Access Gateway Unspecified Security Bypass Vulnerability |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6: Citrix Access Gateway Unspecified Security Bypass 6: Citrix Access Gateway Unspecified Security Bypass Vulnerability V-106: Citrix Access Gateway Unspecified Security Bypass Vulnerability March 7, 2013 - 6:00am Addthis PROBLEM: A vulnerability has been reported in Citrix Access Gateway PLATFORM: Standard Edition 5.0.x prior to 5.0.4.223524. Versions 4.5.x and 4.6.x are not affected by this vulnerability ABSTRACT: A vulnerability has been reported in Citrix Access Gateway, which can be exploited by malicious people to bypass certain security restrictions. REFERENCE LINKS: Secunia Advisory SA52479 Security Tracker Alert ID 1028255 com/id/1028255 CVE-2013-2263 Citrix Knowledge Center IMPACT ASSESSMENT: High DISCUSSION: The vulnerability could allow an unauthenticated user to gain access to network resources. IMPACT:

97

V-103: RSA Authentication Agent Lets Remote Users Bypass Authentication  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3: RSA Authentication Agent Lets Remote Users Bypass 3: RSA Authentication Agent Lets Remote Users Bypass Authentication Requirements V-103: RSA Authentication Agent Lets Remote Users Bypass Authentication Requirements March 4, 2013 - 12:27am Addthis PROBLEM: RSA Authentication Agent Lets Remote Users Bypass Authentication Requirements PLATFORM: RSA Authentication Agent 7.1, 7.1.1 for Microsoft Windows ABSTRACT: A vulnerability was reported in RSA Authentication Agent. REFERENCE LINKS: RSA SecurCare SecurityTracker Alert ID: 1028230 CVE-2013-0931 IMPACT ASSESSMENT: Medium DISCUSSION: On systems configured for Quick PIN Unlock, the system will request a PIN instead of a full Passcode when the session is activated from an active screensaver after the Quick PIN Unlock timeout has expired. RSA Authentication Agent on Windows Vista, Windows 7, Windows 2008, and

98

EA-1262: McKay Bypass Canal Extension, Golden, Colorado  

Energy.gov (U.S. Department of Energy (DOE))

This EA evaluates the environmental impacts for the proposal to extend the McKay Bypass Canal in order to route water from the existing Canal north of the Walnut Creek drainage on the east side of...

99

Technology Transfer: Available Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

test test Please refer to the list of technologies below for licensing and research collaboration availability. If you can't find the technology you're interested in, please contact us at TTD@lbl.gov. Energy ENERGY EFFICIENT TECHNOLOGIES Aerosol Sealing Aerosol Remote Sealing System Clog-free Atomizing and Spray Drying Nozzle Air-stable Nanomaterials for Efficient OLEDs Solvent Processed Nanotube Composites OLEDS with Air-stable Structured Electrodes APIs for Online Energy Saving Tools: Home Energy Saver and EnergyIQ Carbon Dioxide Capture at a Reduced Cost Dynamic Solar Glare Blocking System Electrochromic Device Controlled by Sunlight Electrochromic Windows with Multiple-Cavity Optical Bandpass Filter Electrochromic Window Technology Portfolio Universal Electrochromic Smart Window Coating

100

Bypass flow computations on the LOFA transient in a VHTR  

Science Conference Proceedings (OSTI)

Bypass flow in the prismatic gas-cooled very high temperature reactor (VHTR) is not intentionally designed to occur, but is present in the gaps between graphite blocks. Previous studies of the bypass flow in the core indicated that the cooling provided by flow in the bypass gaps had a significant effect on temperature and flow distributions for normal operating conditions. However, the flow and heat transports in the core are changed significantly after a Loss of Flow Accident (LOFA). This study aims to study the effect and role of the bypass flow after a LOFA in terms of the temperature and flow distributions and for the heat transport out of the core by natural convection of the coolant for a 1/12 symmetric section of the active core which is composed of images and mirror images of two sub-region models. The two sub-region models, 9 x 1/12 and 15 x 1/12 symmetric sectors of the active core, are employed as the CFD flow models using computational grid systems of 70.2 million and 117 million nodes, respectively. It is concluded that the effect of bypass flow is significant for the initial conditions and the beginning of LOFA, but the bypass flow has little effect after a long period of time in the transient computation of natural circulation.

Yu-Hsin Tung; Richard W. Johnson; Yuh-Ming Ferng; Ching-Chang Chieng

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Cermet Filters To Reduce Diesel Engine Emissions  

DOE Green Energy (OSTI)

Pollution from diesel engines is a significant part of our nation's air-quality problem. Even under the more stringent standards for heavy-duty engines set to take effect in 2004, these engines will continue to emit large amounts of nitrogen oxides and particulate matter, both of which affect public health. To address this problem, the Idaho National Engineering and Environmental Laboratory (INEEL) invented a self-cleaning, high temperature, cermet filter that reduces heavy-duty diesel engine emissions. The main advantage of the INEEL cermet filter, compared to current technology, is its ability to destroy carbon particles and NOx in diesel engine exhaust. As a result, this technology is expected to improve our nation's environmental quality by meeting the need for heavy-duty diesel engine emissions control. This paper describes the cermet filter technology and the initial research and development effort.Diesel engines currently emit soot and NOx that pollute our air. It is expected that the U.S. Environmental Protection Agency (EPA) will begin tightening the regulatory requirements to control these emissions. The INEEL's self-cleaning, high temperature cermet filter provides a technology to clean heavy-duty diesel engine emissions. Under high engine exhaust temperatures, the cermet filter simultaneously removes carbon particles and NOx from the exhaust gas. The cermet filter is made from inexpensive starting materials, via net shape bulk forming and a single-step combustion synthesis process, and can be brazed to existing structures. It is self-cleaning, lightweight, mechanically strong, thermal shock resistant, and has a high melting temperature, high heat capacity, and controllable thermal expansion coefficient. The filter's porosity is controlled to provide high removal efficiency for carbon particulate. It can be made catalytic to oxidize CO, H2, and hydrocarbons, and reduce NOx. When activated by engine exhaust, the filter produces NH3 and light hydrocarbon gases that can effectively destroy the NOx in the exhaust. The following sections describe cermet filter technology and properties of the INEEL filter.

Kong, Peter

2001-08-05T23:59:59.000Z

102

Nonlinear image filtering within IDP++  

Science Conference Proceedings (OSTI)

IDP++, image and data processing in C++, is a set of a signal processing libraries written in C++. It is a multi-dimension (up to four dimensions), multi-data type (implemented through templates) signal processing extension to C++. IDP++ takes advantage of the object-oriented compiler technology to provide ``information hiding.`` Users need only know C, not C++. Signals or data sets are treated like any other variable with a defined set of operators and functions. We here some examples of the nonlinear filter library within IDP++. Specifically, the results of MIN, MAX median, {alpha}-trimmed mean, and edge-trimmed mean filters as applied to a real aperture radar (RR) and synthetic aperture radar (SAR) data set.

Lehman, S.K.; Wieting, M.G.; Brase, J.M.

1995-02-09T23:59:59.000Z

103

Evaluation of the complementary use of the ceramic (Kosim) filter and Aquatabs in Northern Region, Ghana  

E-Print Network (OSTI)

The Kosim filter is a ceramic water filter that is currently used in Northern Ghana. Based on prior MIT research in Northern Ghana, this technology is effective at removing 92% of turbidity, 99.4% of total coliforms, and ...

Swanton, Andrew A

2008-01-01T23:59:59.000Z

104

Contactor/filter improvements  

DOE Patents (OSTI)

A contactor/filter arrangement for removing particulate contaminants from a gaseous stream is described. The filter includes a housing having a substantially vertically oriented granular material retention member with upstream and downstream faces, a substantially vertically oriented microporous gas filter element, wherein the retention member and the filter element are spaced apart to provide a zone for the passage of granular material therethrough. A gaseous stream containing particulate contaminants passes through the gas inlet means as well as through the upstream face of the granular material retention member, passing through the retention member, the body of granular material, the microporous gas filter element, exiting out of the gas outlet means. A cover screen isolates the filter element from contact with the moving granular bed. In one embodiment, the granular material is comprised of porous alumina impregnated with CuO, with the cover screen cleaned by the action of the moving granular material as well as by backflow pressure pulses. 6 figs.

Stelman, D.

1988-06-30T23:59:59.000Z

105

INEEL HEPA Filter Leach System: A Mixed Waste Solution  

SciTech Connect

Calciner operations and the fuel dissolution process at the Idaho National Engineering and Environmental Laboratory have generated many mixed waste high-efficiency particulate air (HEPA) filters. The HEPA Filter Leach System located at the Idaho Nuclear Technology and Engineering Center lowers radiation contamination levels and reduces cadmium, chromium, and mercury concentrations on spent HEPA filter media to below disposal limits set by the Resource Conservation and Recovery Act (RCRA). The treated HEPA filters are disposed as low-level radioactive waste. The technical basis for the existing system was established and optimized in initial studies using simulants in 1992. The treatment concept was validated for EPA approval in 1994 by leaching six New Waste Calcining Facility spent HEPA filters. Post-leach filter media sampling results for all six filters showed that both hazardous and radiological constituent levels were reduced so the filters could be disposed of as low-level radioactive waste. Since the validation tests the HEPA Filter Leach System has processed 78 filters in 1997 and 1998. The Idaho National Engineering and Environmental Laboratory HEPA Filter Leach System is the only mixed waste HEPA treatment system in the DOE complex. This process is of interest to many of the other DOE facilities and commercial companies that have generated mixed waste HEPA filters but currently do not have a treatment option available.

Argyle, Mark Don; Demmer, Ricky Lynn; Archibald, Kip Ernest; Brewer, Ken Neal; Pierson, Kenneth Alan; Shackelford, Kimberlee Rene; Kline, Kelli Suzanne

1999-03-01T23:59:59.000Z

106

INEEL HEPA Filter Leach System: A Mixed Waste Solution  

SciTech Connect

Calciner operations and the fuel dissolution process at the Idaho National Engineering and Environmental Laboratory have generated many mixed waste high-efficiency particulate air (HEPA)filters. The HEPA Filter Leach System located at the Idaho Nuclear Technology and Engineering Center lowers radiation contamination levels and reduces cadmium, chromium, and mercury concentrations on spent HEPA filter media to below disposal limits set by the Resource Conservation and Recovery Act (RCRA). The treated HEPA filters are disposed as low-level radioactive waste. The technical basis for the existing system was established and optimized in initial studies using simulants in 1992. The treatment concept was validated for EPA approval in 1994 by leaching six New Waste Calcining Facility spent HEPA filters. Post-leach filter media sampling results for all six filters showed that both hazardous and radiological constituent levels were reduced so the filters could be disposed of as low-level radioactive waste. Since the validation tests the HEPA Filter Leach System has processed 78 filters in 1997 and 1998. The Idaho National Engineering and Environmental Laboratory HEPA Filter Leach System is the only mixed waste HEPA treatment system in the DOE complex. This process is of interest to many of the other DOE facilities and commercial companies that have generated mixed waste HEPA filters but currently do not have a treatment option available.

K. Archibald; K. Brewer; K. Kline; K. Pierson; K. Shackelford; M. Argyle; R. Demmer

1999-02-01T23:59:59.000Z

107

Development of A Microwave Assisted Particulate Filter Regeneration System  

DOE Green Energy (OSTI)

The need for active regeneration of diesel particulate filters and the advantages of microwave assisted regeneration are discussed. The current study has multiple objectives, which include developing a microwave assisted particulate filter regeneration system for future generation light-duty diesel applications, including PNGV type applications. A variable power 2.0 kW microwave system and a tuned waveguide were employed. Cavity geometry is being optimized with the aid of computational modeling and temperature measurements during microwave heating. A wall-flow ceramic-fiber filter with superior thermal shock resistance, high filtration efficiency, and high soot capacity was used. The microwave assisted particulate filter regeneration system has operated for more than 100 hours in an engine test-cell with a 5.9-liter diesel engine with automated split exhaust flow and by-pass flow capabilities. Filter regeneration was demonstrated using soot loads up to 10 g/liter and engine exhaust at idling flow rates as the oxygen source. A parametric study to determine the optimal combination of soot loading, oxidant flow rate, microwave power and heating time is underway. Preliminary experimental results are reported.

Popuri, Sriram

2001-08-05T23:59:59.000Z

108

Advances in Filter Miniaturization and Design/Analysis of RF MEMS Tunable Filters  

E-Print Network (OSTI)

The main purpose of this dissertation was to address key issues in the design and analysis of RF/microwave filters for wireless applications. Since RF/microwave filters are one of the bulkiest parts of communication systems, their miniaturization is one of the most important technological challenges for the development of compact transceivers. In this work, novel miniaturization techniques were investigated for single-band, dual-band, ultra-wideband and tunable bandpass filters. In single-band filters, the use of cross-shaped fractals in half-mode substrate-integrated-waveguide bandpass filters resulted in a 37 percent size reduction. A compact bandpass filter that occupies an area of 0.315 mm2 is implemented in 90-nm CMOS technology for 20 GHz applications. For dual-band filters, using half-mode substrate-integrated-waveguides resulted in a filter that is six times smaller than its full-mode counterpart. For ultra-wideband filters, using slow-wave capacitively-loaded coplanar-waveguides resulted in a filter with improved stopband performance and frequency notch, while being 25 percent smaller in size. A major part of this work also dealt with the concept of 'hybrid' RF MEMS tunable filters where packaged, off-the-shelf RF MEMS switches were used to implement high-performance tunable filters using substrate-integrated-waveguide technology. These 'hybrid' filters are very easily fabricated compared to current state-of-the-art RF MEMS tunable filters because they do not require a clean-room facility. Both the full-mode and half-mode substrate-integrated waveguide tunable filters reported in this work have the best Q-factors (93 - 132 and 75 - 140, respectively) compared to any 'hybrid' RF MEMS tunable filter reported in current literature. Also, the half-mode substrate-integrated waveguide tunable filter is 2.5 times smaller than its full-mode counterpart while having similar performance. This dissertation also presented detailed analytical and simulation-based studies of nonlinear noise phenomena induced by Brownian motion in all-pole RF MEMS tunable filters. Two independent mathematical methods are proposed to calculate phase noise in RF MEMS tunable filters: (1) pole-perturbation approach, and (2) admittance-approach. These methods are compared to each other and to harmonic balance noise simulations using the CAD-model of the RF MEMS switch. To account for the switch nonlinearity in the mathematical methods, a nonlinear nodal analysis technique for tunable filters is also presented. In summary, it is shown that output signal-to-noise ratio degradation due to Brownian motion is maximum for low fractional bandwidth, high order and high quality factor RF MEMS tunable filters. Finally, a self-sustained microwave platform to detect the dielectric constant of organic liquids is presented in this dissertation. The main idea is to use a voltage- controlled negative-resistance oscillator whose frequency of oscillation varies according to the organic liquid under test. To make the system self-sustained, the oscillator is embedded in a frequency synthesizer system, which is then digitally interfaced to a computer for calculation of dielectric constant. Such a system has potential uses in a variety of applications in medicine, agriculture and pharmaceuticals.

Sekar, Vikram

2011-08-01T23:59:59.000Z

109

Linear phase compressive filter  

DOE Patents (OSTI)

A phase linear filter for soliton suppression is in the form of a laddered series of stages of non-commensurate low pass filters with each low pass filter having a series coupled inductance (L) and a reverse biased, voltage dependent varactor diode, to ground which acts as a variable capacitance (C). L and C values are set to levels which correspond to a linear or conventional phase linear filter. Inductance is mapped directly from that of an equivalent nonlinear transmission line and capacitance is mapped from the linear case using a large signal equivalent of a nonlinear transmission line.

McEwan, Thomas E. (Livermore, CA)

1995-01-01T23:59:59.000Z

110

Evaluation of a Cyclone and Hot Gas Filter System  

NLE Websites -- All DOE Office Websites (Extended Search)

a Cyclone and a Cyclone and Hot Gas Filter System Description The Wabash River Coal Gasification Plant uses an oxygen-blown E-Gas gasifier technology, owned by ConocoPhillips, which produces fuel gas containing significant amounts of fine particulates. Currently, particulates are cleaned from the fuel gas with metal candle filters. These filters require two costly plant shut-downs per year for cleaning or replacement. During the U.S Department of Energy-supported project

111

Filter holder and gasket assembly for candle or tube filters  

DOE Patents (OSTI)

A filter holder and gasket assembly for holding a candle filter element within a hot gas cleanup system pressure vessel. The filter holder and gasket assembly includes a filter housing, an annular spacer ring securely attached within the filter housing, a gasket sock, a top gasket, a middle gasket and a cast nut.

Lippert, Thomas Edwin (Murrysville, PA); Alvin, Mary Anne (Pittsburgh, PA); Bruck, Gerald Joseph (Murrysville, PA); Smeltzer, Eugene E. (Export, PA)

1999-03-02T23:59:59.000Z

112

Photovoltaic-module bypass-diode encapsulation. Annual report  

DOE Green Energy (OSTI)

The design and processing techniques necessary to incorporate bypass diodes within the module encapsulant are presented in this annual report. A comprehensive survey of available pad-mounted PN junction and Schottky diodes led to the selection of Semicon PN junction diode cells for this application. Diode junction-to-heat spreader thermal resistance measurements, performed on a variety of mounted diode chip types and sizes, have yielded values which are consistently below 1/sup 0/C per watt, but show some instability when thermally cycled over the temperature range from -40 to 150/sup 0/C. Based on the results of a detailed thermal analysis, which covered the range of bypass currents from 2 to 20 amperes, three representative experimental modules, each incorporating integral bypass diode/heat spreader assemblies of various sizes, were designed and fabricated. Thermal testing of these modules has enabled the formation of a recommended heat spreader plate sizing relationship. The production cost of three encapsulated bypass diode/heat spreader assemblies were compared with similarly rated externally-mounted packaged diodes. An assessment of bypass diode reliability, which relies heavily on rectifying diode failure rate data, leads to the general conclusion that, when proper designed and installed, these devices will improve the overall reliability of a terrestrial array over a 20 year design lifetime.

Not Available

1983-06-20T23:59:59.000Z

113

Moving granular-bed filter development program. Topical report  

Science Conference Proceedings (OSTI)

Advanced, coal-based, power plants, such as IGCC and Advanced-PFBC, are currently nearing commercial demonstration. These power plant technologies require hot gas filtration as part of their gas cleaning trains. Ceramic barrier filters are the major filter candidates being developed for these hot gas cleaning applications. While ceramic barrier filters achieve high levels of particle removal, concerns exist for their reliability and operability in these applications. An alternative hot gas filtration technology is the moving granular bed filter. An advanced, moving granular bed filter has been conceived, and early development activities performed by the Westinghouse Electric Corporation, Science and Technology Center. This document reports on the Base Contract tasks performed to resolve the barrier technical issues for this technology. The concept, the Standleg Moving Granular Bed Filter (SMGBF) has a concurrent downward, gas and bed media flow configuration that results in simplified features and improved scaleup feasibility compared to alternative designs. Two modes of bed media operation were assessed in the program: once-through using pelletized power plant waste as bed media, and recycle of bed media via standleg and pneumatic transport techniques. Cold Model testing; high-temperature, high-pressure testing; and pelletization testing using advanced power plant wastes, have been conducted in the program. A commercial, economic assessment of the SMGBF technology was performed for IGCC and Advanced-PFBC applications. The evaluation shows that the barrier technical issues can be resolved, and that the technology is potentially competitive with ceramic barrier filters.

Newby, R.A.; Yang, W.C.; Smeltzer, E.E.; Lippert, T.E.

1994-04-01T23:59:59.000Z

114

Electrostatic precipitators vs. fabric filters: A symposium and debate  

SciTech Connect

Nine papers were presented at the Electrostatic Precipitators vs. Fabric Filters: A Symposium and Debate held March 22, 1994 at the Sheraton Crystal City Hotel in Arlington, Virginia. The Symposium was intended to take a frank look at the comparative advantages of electrostatic precipitators and fabric filters. A separate abstract was prepared for each paper for inclusion in the Energy Science and Technology Database.

1994-12-31T23:59:59.000Z

115

Architectural implications of spatial thermal filtering  

Science Conference Proceedings (OSTI)

Process technology scaling, lagging supply voltage scaling, and the resulting exponential increase in power density, have made temperature a first-class design constraint in today's microprocessors. Prior work has shown that the silicon substrate acts ... Keywords: Aspect ratio, Granularity, Many-core, Spatial filtering, Temperature, Thermal management

Karthik Sankaranarayanan; Brett H. Meyer; Wei Huang; Robert Ribando; Hossein Haj-Hariri; Mircea R. Stan; Kevin Skadron

2013-01-01T23:59:59.000Z

116

Sub-micron filter  

DOE Patents (OSTI)

Aluminum hydroxide fibers approximately 2 nanometers in diameter and with surface areas ranging from 200 to 650 m.sup.2/g have been found to be highly electropositive. When dispersed in water they are able to attach to and retain electronegative particles. When combined into a composite filter with other fibers or particles they can filter bacteria and nano size particulates such as viruses and colloidal particles at high flux through the filter. Such filters can be used for purification and sterilization of water, biological, medical and pharmaceutical fluids, and as a collector/concentrator for detection and assay of microbes and viruses. The alumina fibers are also capable of filtering sub-micron inorganic and metallic particles to produce ultra pure water. The fibers are suitable as a substrate for growth of cells. Macromolecules such as proteins may be separated from each other based on their electronegative charges.

Tepper, Frederick (Sanford, FL); Kaledin, Leonid (Port Orange, FL)

2009-10-13T23:59:59.000Z

117

Sintered composite filter  

DOE Patents (OSTI)

A particulate filter medium formed of a sintered composite of 0.5 micron diameter quartz fibers and 2 micron diameter stainless steel fibers is described. Preferred composition is about 40 vol.% quartz and about 60 vol.% stainless steel fibers. The media is sintered at about 1100/sup 0/C to bond the stainless steel fibers into a cage network which holds the quartz fibers. High filter efficiency and low flow resistance are provided by the smaller quartz fibers. High strength is provided by the stainless steel fibers. The resulting media has a high efficiency and low pressure drop similar to the standard HEPA media, with tensile strength at least four times greater, and a maximum operating temperature of about 550/sup 0/C. The invention also includes methods to form the composite media and a HEPA filter utilizing the composite media. The filter media can be used to filter particles in both liquids and gases.

Bergman, W.

1986-05-02T23:59:59.000Z

118

Ceramic fiber reinforced filter  

DOE Patents (OSTI)

A filter for removing particulate matter from high temperature flowing fluids, and in particular gases, that is reinforced with ceramic fibers. The filter has a ceramic base fiber material in the form of a fabric, felt, paper of the like, with the refractory fibers thereof coated with a thin layer of a protective and bonding refractory applied by chemical vapor deposition techniques. This coating causes each fiber to be physically joined to adjoining fibers so as to prevent movement of the fibers during use and to increase the strength and toughness of the composite filter. Further, the coating can be selected to minimize any reactions between the constituents of the fluids and the fibers. A description is given of the formation of a composite filter using a felt preform of commercial silicon carbide fibers together with the coating of these fibers with pure silicon carbide. Filter efficiency approaching 100% has been demonstrated with these filters. The fiber base material is alternately made from aluminosilicate fibers, zirconia fibers and alumina fibers. Coating with Al.sub.2 O.sub.3 is also described. Advanced configurations for the composite filter are suggested.

Stinton, David P. (Knoxville, TN); McLaughlin, Jerry C. (Oak Ridge, TN); Lowden, Richard A. (Powell, TN)

1991-01-01T23:59:59.000Z

119

INEEL/EXT-97-  

NLE Websites -- All DOE Office Websites (Extended Search)

4 U.S. Department of Energy FreedomCAR & Vehicle Technologies Program Oil Bypass Filter Technology Evaluation Fourth Quarterly Report July-September 2003 TECHNICAL REPORT Larry...

120

INEEL/EXT-97-  

NLE Websites -- All DOE Office Websites (Extended Search)

620 U.S. Department of Energy FreedomCAR & Vehicle Technologies Oil Bypass Filter Technology Evaluation Second Quarterly Report January - March 2003 Larry Zirker James Francfort...

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Applications of moving granular-bed filters to advanced systems  

SciTech Connect

The contract is arranged as a base contract with three options. The objective of the base contract is to develop conceptual design(s) of moving granular bed filter and ceramic candle filter technology for control of particles from integrated gasification combined cycle (IGCC) systems, pressurized fluidized-bed combustors (PFBC), and direct coal fueled turbine (DCFT) environments. The conceptual design(s) of these filter technologies are compared, primarily from an economic perspective. The granular bed filter was developed through low pressure, high temperature (1600{degree}F) testing in the late 1970`s and early 1980`s. Collection efficiencies over 99% were obtained. In 1988, high pressure, high temperature testing was completed at New York University, Westbury, N.Y., utilizing a two advanced power generating plants were chosen for developing conceptual designs and cost estimates of the commercial sized filters. One is the 450 MWe, second generation pressurized fluidized bed combustion plant defined by Foster Wheeler. This plant originally included cross-flow filters for hot gas cleanup. The other plant under study is a 100 MWe, KRW air blown gasifier. A cross-flow filter was utilized for gas stream cleanup in this study also. Granular bed and ceramic candle filters were substituted for the cross-flow filters in both these plants, and the resulting costs were compared.

Wilson, K.W.; Haas, J.C.; Eshelman, M.B.

1993-09-01T23:59:59.000Z

122

Thermal Reliability Study of Bypass Diodes in Photovoltaic Modules (Poster)  

DOE Green Energy (OSTI)

This paper presents the result of high-temperature durability and thermal cycling testing and analysis for the selected diodes to study the detail of the thermal design and relative long-term reliability of the bypass diodes used to limit the detrimental effects of module hot-spot susceptibility.

Zhang, Z.; Wohlgemuth, J.; Kurtz, S.

2013-05-01T23:59:59.000Z

123

Cycling firing method for bypass operation of bridge converters  

DOE Patents (OSTI)

The bridge converter comprises a number of switching elements and an electronic logic system which regulated the electric power levels by controlling the firing, i.e., the initiation of the conduction period of the switching elements. Cyclic firing of said elements allows the direct current to bypass the alternating current system with high power factor and negligible losses.

Zabar, Zivan (99-72 66th Rd., Apt. 9N, Forest Hills, NY 11375)

1982-01-01T23:59:59.000Z

124

METAL FILTERS FOR PRESSURIZED FLUID BED COMBUSTION (PFBC) APPLICATIONS  

SciTech Connect

Advanced coal and biomass-based gas turbine power generation technologies (IGCC, PFBC, PCFBC, and Hipps) are currently under development and demonstration. Efforts at the Siemens Westinghouse Power Corporation (SWPC) have been focused on the development and demonstration of hot gas filter systems as an enabling technology for power generation. As part of the demonstration effort, SWPC has been actively involved in the development of advanced filter materials and component configuration, has participated in numerous surveillance programs characterizing the material properties and microstructure of field-tested filter elements, and has undertaken extended, accelerated filter life testing programs. This report reviews SWPC's material and component assessment efforts, identifying the performance, stability, and life of porous commercial metal, advanced alloy, and intermetallic filters under simulated, pressurized fluidized-bed combustion (PFBC) conditions.

M.A. Alvin

2004-01-02T23:59:59.000Z

125

Microhydropower Conveyance and Filters  

Energy.gov (U.S. Department of Energy (DOE))

Before water enters the turbine or waterwheel of a microhydropower system, it is funneled through a series of components that control its flow and filter out debris. These components include the...

126

Development of NDE methods for hot gas filters.  

SciTech Connect

Ceramic hot gas candle filters are currently under development for hot gas particulate cleanup in advanced coal-based power systems. The ceramic materials for these filters include nonoxide monolithic, nonoxide-fiber-reinforced composites, and nonoxide reticulated foam. A concern is the lack of reliable data on which to base decisions for reusing or replacing hot gas filters during plant shutdowns. The work in this project is aimed at developing nondestructive evaluation (FIDE) technology to allow detection, and determination of extent, of life-limiting characteristics such as thermal fatigue, oxidation, damage from ash bridging such as localized cracking, damage from local burning, and elongation at elevated temperature. Although in-situ NDE methods are desirable in order to avoid disassembly of the candle filter vessels, the current vessel designs, the presence of filter cakes and possible ash bridging, and the state of NDE technology prevent this. Candle filter producers use a variety of NDE methods to ensure as-produced quality. While impact acoustic resonance offers initial promise for examining new as-produced filters and for detecting damage in some monolithic filters when removed from service, it presents difficulties in data interpretation, it lacks localization capability, and its applicability to composites has yet to be demonstrated. Additional NDE technologies being developed and evaluated in this program and whose applicability to both monolithics and composites has been demonstrated include (a) full-scale thermal imaging for analyzing thermal property variations; (b) fret, high-spatial-resolution X-ray imaging for detecting density variations and dimensional changes; (c) air-coupled ultrasonic methods for determining through-thickness compositional variations; and (d) acoustic emission technology with mechanical loading for detecting localized bulk damage. New and exposed clay-bonded SiC filters and CVI-SiC composite filters have been tested with these additional NDE methods.

Deemer, C.; Ellingson, W. A.; Koehl, E. R.; Lee, H.; Spohnholtz, T.; Sun, J. G.

1999-07-21T23:59:59.000Z

127

Filters for cathodic arc plasmas  

DOE Patents (OSTI)

Cathodic arc plasmas are contaminated with macroparticles. A variety of magnetic plasma filters has been used with various success in removing the macroparticles from the plasma. An open-architecture, bent solenoid filter, with additional field coils at the filter entrance and exit, improves macroparticle filtering. In particular, a double-bent filter that is twisted out of plane forms a very compact and efficient filter. The coil turns further have a flat cross-section to promote macroparticle reflection out of the filter volume. An output conditioning system formed of an expander coil, a straightener coil, and a homogenizer, may be used with the magnetic filter for expanding the filtered plasma beam to cover a larger area of the target. A cathodic arc plasma deposition system using this filter can be used for the deposition of ultrathin amorphous hard carbon (a-C) films for the magnetic storage industry.

Anders, Andre (Albany, CA); MacGill, Robert A. (Richmond, CA); Bilek, Marcela M. M. (Engadine, AU); Brown, Ian G. (Berkeley, CA)

2002-01-01T23:59:59.000Z

128

Remotely serviced filter and housing  

DOE Patents (OSTI)

A filter system for a hot cell comprises a housing adapted for input of air or other gas to be filtered, flow of the air through a filter element, and exit of filtered air. The housing is tapered at the top to make it easy to insert a filter cartridge holds the filter element while the air or other gas is passed through the filter element. Captive bolts in trunnion nuts are readily operated by electromechanical manipulators operating power wrenches to secure and release the filter cartridge. The filter cartridge is adapted to make it easy to change a filter element by using a master-slave manipulator at a shielded window station. 6 figs.

Ross, M.J.; Zaladonis, L.A.

1987-07-22T23:59:59.000Z

129

DEVELOPMENT OF METALLIC HOT GAS FILTERS  

SciTech Connect

Successful development of metallic filters with high temperature oxidation/corrosion resistance for fly ash capture is a key to enabling advanced coal combustion and power generation technologies. Compared to ceramic filters, metallic filters can offer increased resistance to impact and thermal fatigue, greatly improving filter reliability. A beneficial metallic filter structure, composed of a thin-wall (0.5mm) tube with uniform porosity (about 30%), is being developed using a unique spherical powder processing and partial sintering approach, combined with porous sheet rolling and resistance welding. Alloy choices based on modified superalloys, e.g., Ni-16Cr-4.5Al-3Fe (wt.%), are being tested in porous and bulk samples for oxide (typically alumina) scale stability in simulated oxidizing/sulfidizing atmospheres found in PFBC and IGCC systems at temperatures up to 850 C. Recent ''hanging o-ring'' exposure tests in actual combustion systems at a collaborating DOE site (EERC) have been initiated to study the combined corrosive effects from particulate deposits and hot exhaust gases. New studies are exploring the correlation between sintered microstructure, tensile strength, and permeability of porous sheet samples.

Anderson, I.E.; Gleeson, B.; Terpstra, R.L.

2003-04-23T23:59:59.000Z

130

Moving granular-bed filter development program topical report  

SciTech Connect

The Westinghouse Science Technology Center has proposed a novel moving granular-bed filter concept, the Standleg Moving Granular-Bed Filter (S-MGBF) system, that overcomes the inherent deficiencies of the current state-of-the-art moving granular-bed filter technology. The S-MGBF system combines two unique features that make it highly effective for use in advanced coal-fueled power plants. First, the S-MGBF system applies pelletization technology to generate filter pellets from the power plant solid waste materials, and uses these pellets as a once-through'' filtering media to eliminate the need for costly, complex, and large filter media recycling equipment. This pelletizing step also generates a more environmentally acceptable solid waste product and provides the potential to incorporate gas-phase contaminant sorbents into the filtering media. Secondly, the S-MGBF system passes these pellets and the flyash laden power plant gas through a highly compact S-MGBF that uses cocurrent gas-pellet contacting in an arrangement that greatly simplifies and enhances the distribution of dirty gas to the moving bed and the disengagement of clean gas from the moving bed.

Newby, R.A.; Dilmore, W.J.; Fellers, A.W.; Gasparovic, A.C.; Kittle, W.F.; Lippert, T.E.; Smeltzer, E.E.; Yang, W.C.

1991-10-17T23:59:59.000Z

131

Evaluation of Alternative Filter Media for the Rotary Microfilter  

SciTech Connect

The Savannah River Site is currently developing and testing several processes to treat high level radioactive liquid waste. Each of these processes has a solid-liquid separation process that limits its throughput. Savannah River National Laboratory researchers identified and tested the rotary microfilter as a technology to increase solid-liquid separation throughput. The authors believe the rotary microfilter throughput can be improved by using a better filter membrane. Previous testing showed that asymmetric filters composed of a ceramic membrane on top of a stainless steel support produced higher filter flux than 100% stainless steel symmetric filters in crossflow filter tests. Savannah River National Laboratory and Oak Ridge National Laboratory are working together to develop asymmetric ceramic ? stainless steel composite filters and asymmetric 100% stainless steel filters to improve the throughput of the rotary microfilter. The Oak Ridge National Laboratory Inorganic Membrane Group fabricated samples of alternative filter membranes. In addition, Savannah River National Laboratory obtained samples of filter membranes from Pall, Porvair, and SpinTek. They tested these samples in a static test cell with feed slurries containing monosodium titanate and simulated sludge.

Poirier, M. R.; Herman, D. T.; Bhave, R.

2011-11-09T23:59:59.000Z

132

High Efficiency Particulate Air Filters  

NLE Websites -- All DOE Office Websites (Extended Search)

High Efficiency Particulate Air (HEPA) Filters High Efficiency Particulate Air (HEPA) Filters Home Standards DOE Workshops Nuclear Air Cleaning Conference Proceedings Qualified Filter List News Items Related Sites HEPA Related Lessons Learned Contact Us HSS Logo High Efficiency Particulate Air Filters The HEPA Filter web site provides a forum for informing and reporting department-wide activities related to filtration and ventilation issues with special reference to the High Efficiency Particulate Air (HEPA) Filters' use, inspection, and testing. This site contains essentials of DOE HEPA filter test program, procedures, requirements and quality assurance aspects applicable to HEPA filters used in DOE facilities. This site contains information about the DOE-accepted Filter Test Facility and its management, operation and quality assuranceprogram.

133

Marine and Hydrokinetic Technology Database  

DOE Data Explorer (OSTI)

Results are displayed as a list of technologies, companies, or projects. Data can be filtered by a number of criteria, including country/region, technology type, generation capacity, and technology or project stage. The database is currently (2009) being updated to include ocean thermal energy technologies, companies, and projects.[Taken from http://www2.eere.energy.gov/windandhydro/hydrokinetic/

134

Spam filtering using Kolmogorov complexity analysis  

Science Conference Proceedings (OSTI)

One of the most irrelevant side effects of e-commerce technology is the development of spamming as an e-marketing technique. Spam e-mails (or unsolicited commercial e-mails) induce a burden for everybody having an electronic mailbox: detecting and ... Keywords: Kolmogorov complexity, anti-spam techniques, clustering, compression, e-marketing, information content, k-nearest neighbours, spam filtering, spamming, unsolicited e-mails

G. Richard; A. Doncescu

2008-05-01T23:59:59.000Z

135

NREL: Technology Transfer - NREL Collaborates to Commercialize ...  

Natural gas. Nuclear waste. Nuclear Filter Technology is also licensing several NREL inventions related to the fiber optic and thin film materials that sense the ...

136

Filter assembly for metallic and intermetallic tube filters  

Science Conference Proceedings (OSTI)

A filter assembly (60) for holding a filter element (28) within a hot gas cleanup system pressure vessel is provided, containing: a filter housing (62), said filter housing having a certain axial length and having a peripheral sidewall, said sidewall defining an interior chamber (66); a one piece, all metal, fail-safe/regenerator device (68) within the interior chamber (66) of the filter housing (62) and/or extending beyond the axial length of the filter housing, said device containing an outward extending radial flange (71) within the filter housing for seating an essential seal (70), the device also having heat transfer media (72) disposed inside and screens (80) for particulate removal; one compliant gasket (70) positioned next to and above the outward extending radial flange of the fail-safe/regenerator device; and a porous metallic corrosion resistant superalloy type filter element body welded at the bottom of the metal fail-safe/regenerator device.

Alvin, Mary Anne (113 Lehr Ave., Pittsburgh, PA 15223); Lippert, Thomas E. (3205 Cambridge Rd., Murrysville, PA 15668); Bruck, Gerald J. (4469 Sardis Rd., Murrysville, PA 15668); Smeltzer, Eugene E. (R.D. 7, Box 267-I, Italy Rd., Export, PA 15632-9621)

2001-01-01T23:59:59.000Z

137

Ozone decomposing filter  

DOE Patents (OSTI)

In an improved ozone decomposing air filter carbon fibers are held together with a carbonized binder in a perforated structure. The structure is made by combining rayon fibers with gelatin, forming the mixture in a mold, freeze-drying, and vacuum baking.

Simandl, Ronald F. (Farragut, TN); Brown, John D. (Harriman, TN); Whinnery, Jr., LeRoy L. (Dublin, CA)

1999-01-01T23:59:59.000Z

138

Diffusion and Numerical Filters  

Science Conference Proceedings (OSTI)

Applications of low-pass filters or implicit diffusion are found to be extremely beneficial in a simple model problem that contains an oven-ordered advection scheme based on a symmetric stencil. In contrast, the effects are negative when either ...

William H. Raymond

1994-04-01T23:59:59.000Z

139

NETL: Gasification - Long-Term Candle Filter Tests  

NLE Websites -- All DOE Office Websites (Extended Search)

Long-Term Candle Filter Tests Long-Term Candle Filter Tests National Carbon Capture Center at the Power Systems Development Facility Southern Company Services, Inc. Project Number: NT0000749 Project Description The National Carbon Capture Center advancement of hot gas filtration technology provides the design for optimal, long-term evaluation of material performance for particulate control device (PCD) filter elements. Testing is performed using the commercially available Siemens PCD, due to its demonstrated excellent collection efficiency during normal operation. The PCD, located downstream of the primary gas cooler, houses up to 91 candle-type filter elements. They're currently used in the development of candle filters that can efficiently remove particulates at varying temperatures, using low-cost materials and innovative design.

140

Development of ceramic composite hot-gas filters  

SciTech Connect

A novel type of hot-gas filter based on a ceramic fiber-reinforced ceramic matrix was developed and extended to fullsize, 60-mm OD by 1.5-meter-long, candle filters. A commercially viable process for producing the filters was developed, and the filters are undergoing testing and demonstration throughout the world for applications in pressurized fluidized-bed combustion (PFBC) and integrated gasification combined cycle (IGCC) plants. Development activities at Oak Ridge National Laboratory (ORNL) and at the 3M Company, and testing at the Westinghouse Science and Technology Center (STC) are presented. Demonstration tests at the Tidd PFBC are underway. Issues identified during the testing and demonstration phases of the development are discussed. Resolution of the issues and the status of commercialization of the filters are described.

Judkins, R.R.; Stinton, D.P. [Oak Ridge National Lab., TN (United States); Smith, R.G.; Fischer, E.M.; Eaton, J.H.; Weaver, B.L.; Kahnke, J.L.; Pysher, D.J. [3M Co., St. Paul, MN (United States)

1995-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Development of ceramic composite hot-gas filters  

SciTech Connect

A novel type of hot-gas filter based on a ceramic fiber-reinforced ceramic matrix was developed and extended to full-size, 60-mm OD by 1.5-m-long, candle filters. A commercially viable process for producing the filters was developed, and the filters are undergoing testing and demonstration throughout the world for applications in pressurized fluidized-bed combustion (PFBC) and integrated gasification combined cycle (IGCC) plants. Development activities at Oak Ridge National Laboratory (ORNL) and at the 3M Company, and testing at the Westinghouse Science and Technology Center (STC) are presented. Demonstration tests at the Tidd PFBC are in progress. Issues identified during the testing and demonstration phases of the development are discussed. Resolution of the issues identified during testing and the status of commercialization of the filters are described.

Judkins, R.R.; Stinton, D.P. [Oak Ridge National Lab., TN (United States); Smith, R.G.; Fischer, E.M.; Eaton, J.H.; Weaver, B.L.; Kahnke, J.L.; Pysher, D.J. [3M Co., St. Paul, MN (United States)

1996-07-01T23:59:59.000Z

142

U-061: RSA Adaptive Authentication Bugs Let Remote Users Bypass Certain  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1: RSA Adaptive Authentication Bugs Let Remote Users Bypass 1: RSA Adaptive Authentication Bugs Let Remote Users Bypass Certain Security Controls U-061: RSA Adaptive Authentication Bugs Let Remote Users Bypass Certain Security Controls December 14, 2011 - 8:17am Addthis PROBLEM: RSA Adaptive Authentication Bugs Let Remote Users Bypass Certain Security Controls. PLATFORM: 6.0.2.1 SP1 Patch 2 and SP1 Patch 3 6.0.2.1 SP2 and SP2 Patch 1 6.0.2.1 SP3 ABSTRACT: A remote user may be able to bypass certain security controls. reference LINKS: SecurityTracker Alert ID: 1026420 Security Focus: ESA-2011-036 IMPACT ASSESSMENT: Medium Discussion: Two vulnerabilities were reported in RSA Adaptive Authentication (On-Premise). A remote user may be able to bypass certain security controls. A remote user can send specially crafted data elements to affect the Device

143

V-057: eXtplorer "ext_find_user()" Authentication Bypass Vulnerability |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

V-057: eXtplorer "ext_find_user()" Authentication Bypass V-057: eXtplorer "ext_find_user()" Authentication Bypass Vulnerability V-057: eXtplorer "ext_find_user()" Authentication Bypass Vulnerability December 28, 2012 - 6:00am Addthis December 28 2012 - 6:00am PROBLEM: eXtplorer "ext_find_user()" Authentication Bypass Vulnerability PLATFORM: eXtplorer 2.x ABSTRACT: A vulnerability has been reported in eXtplorer, which can be exploited by malicious people to bypass certain security restrictions. REFERENCE LINKS: Secunia Advisory SA51636 eXtplorer 2.1.3 Security Release IMPACT ASSESSMENT: Medium DISCUSSION: eXtplorer was notified of a problem within the authentication system of eXtplorer Versions 2.1.2, 2.1.1, 2.1.0 and 2.1.0RC5 that have been found to be vulnerable to an authentication bypass bug.

144

U-234: Oracle MySQL User Login Security Bypass Vulnerability | Department  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

234: Oracle MySQL User Login Security Bypass Vulnerability 234: Oracle MySQL User Login Security Bypass Vulnerability U-234: Oracle MySQL User Login Security Bypass Vulnerability August 14, 2012 - 7:00am Addthis PROBLEM: Oracle MySQL User Login Security Bypass Vulnerability PLATFORM: Version(s): prior to 5.1.63 and 5.5.25 are vulnerable. ABSTRACT: Oracle MySQL is prone to a security bypass vulnerability Attackers can exploit this issue to bypass certain security restrictions. REFERENCE LINKS: http://www.securityfocus.com/bid/53911/discuss CVE-2012-2122 IMPACT ASSESSMENT: Medium Discussion: Security researchers have released details about a vulnerability in the MySQL server that could allow potential attackers to access MySQL databases without inputting proper authentication credentials.The vulnerability is identified as CVE-2012-2122 and was addressed in MySQL 5.1.63 and 5.5.25 in

145

METAL MEDIA FILTERS, AG-1 SECTION FI  

Science Conference Proceedings (OSTI)

One application of metal media filters is in various nuclear air cleaning processes including applications for protecting workers, the public and the environment from hazardous and radioactive particles. To support this application the development of the ASME AG-1 FI Standard on Metal Media has been under way for more than ten years. Development of the proposed section has required resolving several difficult issues associated with operating conditions (media velocity, pressure drop, etc.), qualification testing, and quality acceptance testing. Performance characteristics of metal media are dramatically different than the glass fiber media with respect to parameters like differential pressures, operating temperatures, media strength, etc. These differences make existing data for a glass fiber media inadequate for qualifying a metal media filter for AG-1. In the past much work has been conducted on metal media filters at facilities such as Lawrence Livermore National Laboratory (LLNL) and Savannah River National Laboratory (SRNL) to qualify the media as High Efficiency Particulate Air (HEPA) Filters. Particle retention testing has been conducted at Oak Ridge Filter Test Facility and at Air Techniques International (ATI) to prove that the metal media meets or exceeds the 99.97% particle retention required for a HEPA Filter. Even with his testing, data was lacking to complete an AG-1 FI Standard on metal media. With funding secured by Mississippi State University (MSU) from National Nuclear Security Administration (NNSA), a research test stand is being designed and fabricated at MSU's Institute for Clean Energy Technology (ICET) Facility to obtain qualification data on metal media. This in turn will support required data needed for the FI Standard. The paper will discuss in detail how the test stand at MSU will obtain the necessary data to complete the FI Standard.

Adamson, D.

2012-05-23T23:59:59.000Z

146

Particle Filtering in Geophysical Systems  

Science Conference Proceedings (OSTI)

The application of particle filters in geophysical systems is reviewed. Some background on Bayesian filtering is provided, and the existing methods are discussed. The emphasis is on the methodology, and not so much on the applications themselves. ...

Peter Jan van Leeuwen

2009-12-01T23:59:59.000Z

147

Fuel Cell Technologies Overview  

NLE Websites -- All DOE Office Websites (Extended Search)

States Energy Advisory Board (STEAB) States Energy Advisory Board (STEAB) Washington, DC Dr. Sunita Satyapal U.S. Department of Energy Fuel Cell Technologies Program Program Manager 3/14/2012 2 | Fuel Cell Technologies Program Source: US DOE 3/19/2013 eere.energy.gov * Introduction - Technology and Market Overview * DOE Program Overview - Mission & Structure - R&D Progress - Demonstration & Deployments * State Activities - Examples of potential opportunities Outline 3 | Fuel Cell Technologies Program Source: US DOE 3/19/2013 eere.energy.gov Fuel cells - convert chemical energy directly into electrical energy, bypassing inefficiencies associated with thermal energy conversion. Available energy is equal to the Gibbs free energy. Combustion Engines - convert chemical energy into thermal energy and

148

2010 EPRI-Southern Company Services Fabric Filter Workshop Proceedings  

Science Conference Proceedings (OSTI)

The use of fabric filters (also called baghouses) on coal-fired boilers in power plants has increased significantly in the past several years due to increasingly stringent particulate matter emissions limits. These limits have become even more challenging in light of the proposed maximum achievable control technology (MACT) ruling for air toxics by the U.S. Environmental Protection Agency on March 16, 2011. The proposed MACT ruling will require control of both filterable and condensable particulate matte...

2011-04-28T23:59:59.000Z

149

DEVELOPMENT OF AN ADHESIVE CANDLE FILTER SAFEGUARD DEVICE  

SciTech Connect

In order to reach the highest possible efficiencies in a coal-fired turbine-based power system, the turbine should be directly fired with the products of coal conversion. Two main types of systems employ these turbines: those based on pressurized fluidized-bed combustors and those based on integrated gasification combined cycles. In both systems, suspended particulates must be cleaned from the gas stream before it enters the turbine so as to prevent fouling and erosion of the turbine blades. To produce the cleanest gas, barrier filters are being developed and are in use in several facilities. Barrier filters are composed of porous, high-temperature materials that allow the hot gas to pass but collect the particulates on the surface. The three main configurations of the barrier filters are candle, cross-flow, and tube filters. Both candle and tube filters have been tested extensively. They are composed of coarsely porous ceramic that serves as a structural support, overlain with a thin, microporous ceramic layer on the dirty gas side that serves as the primary filter surface. They are highly efficient at removing particulate matter from the gas stream and, because of their ceramic construction, are resistant to gas and ash corrosion. However, ceramics are brittle and individual elements can fail, allowing particulates to pass through the hole left by the filter element and erode the turbine. Preventing all failure of individual ceramic filter elements is not possible at the present state of development of the technology. Therefore, safeguard devices (SGDs) must be employed to prevent the particulates streaming through occasional broken filters from reaching the turbine. However, the SGD must allow for the free passage of gas when it is not activated. Upon breaking of a filter, the SGD must either mechanically close or quickly plug with filter dust to prevent additional dust from reaching the turbine. Production of a dependable rapidly closing autonomous mechanical device at high temperatures in a dusty gas stream is difficult because of problems with materials corrosion, dust leakage, and detection of filter failure. Therefore, the Energy & Environmental Research Center is using its knowledge of the factors that make filter dust sticky at gas filtration temperatures to make a simple and inexpensive SGD that employs an adhesive yet thermodynamically stable coating on a highly porous ceramic substrate. The SGDs are placed on top of individual candle filters at the filtered gas exit. Upon failure of the filter, the dirty gas flows through the SGD where the adhesive surface rapidly and permanently traps dust particles, causing the device to plug and prevent the dust from reaching the turbine.

John P. Hurley; Ann K. Henderson; Jan W. Nowok; Michael L. Swanson

2002-01-01T23:59:59.000Z

150

Westinghouse standleg moving granular bed filter development program  

SciTech Connect

Advanced, coal-based, power plants, such as IGCC and Advanced-PFBC, are currently nearing commercial demonstration. These power plant technologies require hot gas filtration as part of their gas cleaning trains. Ceramic barrier filters are the major filter candidates being developed for these hot gas cleaning applications. While ceramic barrier filters achieve high levels of particle removal, there are concerns for their reliability and operability. An alternative hot gas filtration technology is the moving granular bed filter. These systems are at a lower state of development than ceramic barrier filters, and their effectiveness as filters is still in question. Their apparent attributes, result from their much less severe mechanical design and materials constraints, and the potential for more reliable, failure-free particle removal operation. The standleg moving granular-bed filter (SMGBF) system, is a compact unit that uses cocurrent gas-pellet contacting in an arrangement that greatly simplifies and enhances the distribution of dirty, process gas to the moving bed and allows effective disengagement of clean gas from the moving bed. This paper describes the equipment and process test results.

Newby, R.A.; Yang, W.C.; Smeltzer, E.E.; Lippert, T.E.

1994-10-01T23:59:59.000Z

151

V-077: Barracuda SSL VPN Bug Lets Remote Users Bypass Authentication...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

property (via 'setSysProp.jsp') to bypass access restrictions and gain access to the API functionality. This can be exploited to download configuration files, download database...

152

V-236: MediaWiki CentralAuth Extension Authentication Bypass...  

NLE Websites -- All DOE Office Websites (Extended Search)

IMPACT ASSESSMENT: Medium DISCUSSION: The vulnerability is caused due to an error when handling auto-logins and can be exploited to bypass the authentication mechanism by...

153

U-247: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Configuration Manager Database Authentication Bypass Vulnerability V-120: EMC Smarts Network Configuration Manager Java RMI Access Control Flaw Lets Remote Users Gain Full Control...

154

Filtered cathodic arc source  

DOE Patents (OSTI)

Disclosed is a continuous, cathodic arc ion source coupled to a macro-particle filter capable of separation or elimination of macro-particles from the ion flux produced by cathodic arc discharge. The ion source employs an axial magnetic field on a cathode (target) having tapered sides to confine the arc, thereby providing high target material utilization. A bent magnetic field is used to guide the metal ions from the target to the part to be coated. The macro-particle filter consists of two straight solenoids, end to end, but placed at 45{degrees} to one another, which prevents line-of-sight from the arc spot on the target to the parts to be coated, yet provides a path for ions and electrons to flow, and includes a series of baffles for trapping the macro-particles.

Falabella, S.; Sanders, D.M.

1992-12-31T23:59:59.000Z

155

Filtered cathodic arc source  

DOE Patents (OSTI)

A continuous, cathodic arc ion source coupled to a macro-particle filter capable of separation or elimination of macro-particles from the ion flux produced by cathodic arc discharge is described. The ion source employs an axial magnetic field on a cathode (target) having tapered sides to confine the arc, thereby providing high target material utilization. A bent magnetic field is used to guide the metal ions from the target to the part to be coated. The macro-particle filter consists of two straight solenoids, end to end, but placed at 45[degree] to one another, which prevents line-of-sight from the arc spot on the target to the parts to be coated, yet provides a path for ions and electrons to flow, and includes a series of baffles for trapping the macro-particles. 3 figures.

Falabella, S.; Sanders, D.M.

1994-01-18T23:59:59.000Z

156

Regenerable particulate filter  

DOE Patents (OSTI)

A method of making a three-dimensional lattice structure, such as a filter used to remove particulates from a gas stream, where the physical lattice structure is designed utilizing software simulation from pre-defined mass transfer and flow characteristics and the designed lattice structure is fabricated using a free-form fabrication manufacturing technique, where the periodic lattice structure is comprised of individual geometric elements.

Stuecker, John N. (Albuquerque, NM); Cesarano, III, Joseph (Albuquerque, NM); Miller, James E. (Albuquerque, NM)

2009-05-05T23:59:59.000Z

157

Siphon filter assessment for Northern Ghana  

E-Print Network (OSTI)

The siphon filter is a household water filter developed by the Basic Water Needs Foundation based on the design of ceramic candle filters. The siphon filter is marketed under brand names CrystalPur and Tulip and is sold ...

Ziff, Sara Elizabeth

2009-01-01T23:59:59.000Z

158

Development of a Pulp Process Treating Contaminated HEPA Filters (III)  

SciTech Connect

The Pulp Process (PP) Treatment option was conceived as a replacement for the current Filter Leaching System (FLS). The FLS has operated at the Idaho Nuclear Technology and Engineering Center of the Idaho National Engineering and Environmental Laboratory since 1995 to treat radioactive, mixed waste HEPA filters. In recent years, the FLS has exhibited difficulty in removing mercury from the HEPA filters as the concentration of mercury in the spent HEPA filters has increased. The FLS leaches and washes the whole filter without any preparation or modification. The filter media and the trapped calcine particles are confined in a heavy filter housing that contributes to poor mixing zones around the edges of the filter, low media permeability, channeling of the liquid through cracks and tears in the filter media, and liquid retention between leach and rinse cycles. In the PP, the filter media and the trapped calcine particles are separated from the filter housing and treated as a pulp, taking advantage of improved contact with the leach solution that cannot be achieved when the media is still in the HEPA filter housing. In addition to removing the mercury more effectively, the PP generates less volume of liquid waste, requires a shorter leach cycle time, and possesses the versatility for treating filters of different sizes. A series of tests have been performed in the laboratory to demonstrate the advantages of the PP concept. These tests compare the PP with the FLS under controlled conditions that simulate the current operating parameters. A prior study using blended feed, a mixture of shredded clean HEPA filter media and non-radioactive calcine particles, indicated that the PP would significantly increases the calcine dissolution percentages. In this study, hazardous-metal contaminated HEPA filter media was studied. The results of side-by-side tests indicated that the PP increased the mercury removal percentage by 80% and might be a solution to the mercury removal problem encountered by the current FLS. A patent application has been filed for the PP and the patent is pending. In order to validate the PP and collect information for engineering design and economical feasibility studies, pilot plant scale tests are planned.

Hu, J. S.; Ramer, J.; Argyle, M. D.; Demmer, R. L.

2002-02-28T23:59:59.000Z

159

Inferring Species Trees Directly from Biallelic Genetic Markers: Bypassing Gene Trees in a Full Coalescent Analysis  

E-Print Network (OSTI)

Inferring Species Trees Directly from Biallelic Genetic Markers: Bypassing Gene Trees in a Full the likelihood of a species tree directly from the markers under a finite-sites model of mutation effectively in an algorithm that allows us to bypass the gene trees and compute species tree likelihoods directly from

Rosenberg, Noah

160

V-186: Drupal Login Security Module Security Bypass and Denial of Service  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6: Drupal Login Security Module Security Bypass and Denial of 6: Drupal Login Security Module Security Bypass and Denial of Service Vulnerability V-186: Drupal Login Security Module Security Bypass and Denial of Service Vulnerability June 26, 2013 - 1:28am Addthis PROBLEM: Drupal Login Security Module Security Bypass and Denial of Service Vulnerability PLATFORM: Login Security 6.x-1.x versions prior to 6.x-1.2. Login Security 7.x-1.x versions prior to 7.x-1.2. ABSTRACT: A security issue and a vulnerability have been reported in the Login Security module for Drupal REFERENCE LINKS: Advisory ID: DRUPAL-SA-CONTRIB-2013-053 Secunia Advisory SA53717 CVE-2013-2197 CVE-2013-2198 IMPACT ASSESSMENT: Medium DISCUSSION: 1) The security issue is caused due to an unspecified error and can be exploited to bypass the module features. Successful exploitation requires the "soft blocking" feature to be

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

V-040: Apache Tomcat Bug Lets Remote Users Bypass Security Constraints |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0: Apache Tomcat Bug Lets Remote Users Bypass Security 0: Apache Tomcat Bug Lets Remote Users Bypass Security Constraints V-040: Apache Tomcat Bug Lets Remote Users Bypass Security Constraints December 5, 2012 - 1:00am Addthis PROBLEM: Apache Tomcat Bug Lets Remote Users Bypass Security Constraints PLATFORM: Version(s): 6.0.0 - 6.0.35, 7.0.0 - 7.0.29 ABSTRACT: A vulnerability was reported in Apache Tomcat. REFERENCE LINKS: Apache Tomcat Red Hat Bugzilla - Bug 883634 SecurityTracker Alert ID: 1027833 CVE-2012-3546 IMPACT ASSESSMENT: High DISCUSSION: When using FORM authentication it was possible to bypass the security constraint checks in the FORM authenticator by appending /j_security_check to the end of the URL if some other component (such as the Single-Sign-On valve) had called request.setUserPrincipal() before the call to

162

T-707: Apache Tomcat AJP Protocol Processing Bug Lets Remote Users Bypass  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7: Apache Tomcat AJP Protocol Processing Bug Lets Remote Users 7: Apache Tomcat AJP Protocol Processing Bug Lets Remote Users Bypass Authentication or Obtain Information T-707: Apache Tomcat AJP Protocol Processing Bug Lets Remote Users Bypass Authentication or Obtain Information August 31, 2011 - 12:00pm Addthis PROBLEM: A vulnerability was reported in Apache Tomcat. A remote user can bypass authentication or obtain potentially sensitive information. PLATFORM: Apache Tomcat 5.5.0 to 5.5.33, 6.0.0 to 6.0.33, 7.0.0 to 7.0.20 ABSTRACT: Apache Tomcat AJP protocol processing bug lets remote users bypass authentication or obtain information. reference LINKS: SecurityTracker Alert ID: 1025993 CVE-2011-3190 (under review) Apache Tomcat Security Updates IMPACT ASSESSMENT: Medium Discussion: A vulnerability was reported in Apache Tomcat. A remote user can bypass

163

V-236: MediaWiki CentralAuth Extension Authentication Bypass Vulnerability  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

6: MediaWiki CentralAuth Extension Authentication Bypass 6: MediaWiki CentralAuth Extension Authentication Bypass Vulnerability V-236: MediaWiki CentralAuth Extension Authentication Bypass Vulnerability September 6, 2013 - 4:36am Addthis PROBLEM: A vulnerability has been reported in the CentralAuth extension for MediaWiki, which can be exploited by malicious people to bypass certain security restrictions. PLATFORM: MediaWiki CentralAuth Extension ABSTRACT: A vulnerability has been reported in the CentralAuth extension for MediaWik REFERENCE LINKS: Secunia Advisory SA54723 IMPACT ASSESSMENT: Medium DISCUSSION: The vulnerability is caused due to an error when handling auto-logins and can be exploited to bypass the authentication mechanism by providing a valid username within the "centralauth_User" cookie. IMPACT:

164

V-052: Drupal Core Access Bypass and Arbitrary PHP Code Execution  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

52: Drupal Core Access Bypass and Arbitrary PHP Code Execution 52: Drupal Core Access Bypass and Arbitrary PHP Code Execution Vulnerabilities V-052: Drupal Core Access Bypass and Arbitrary PHP Code Execution Vulnerabilities December 21, 2012 - 12:15am Addthis PROBLEM: Drupal Core Access Bypass and Arbitrary PHP Code Execution Vulnerabilities PLATFORM: Drupal 6.x versions prior to 6.27 Drupal 7.x versions prior to 7.18 ABSTRACT: Drupal Core Multiple vulnerabilities REFERENCE LINKS: SA-CORE-2012-004 - Drupal core Bugtraq ID: 56993 Secunia Advisory SA51517 CVE-2012-5651 CVE-2012-5652 CVE-2012-5653 IMPACT ASSESSMENT: Medium DISCUSSION: An attacker can exploit these issues to execute arbitrary PHP code within the context of the web server, bypass certain security restrictions, and perform unauthorized actions; this may aid in launching further attacks.

165

V-017: Apache Tomcat Security Bypass and Denial of Service Vulnerabilities  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7: Apache Tomcat Security Bypass and Denial of Service 7: Apache Tomcat Security Bypass and Denial of Service Vulnerabilities V-017: Apache Tomcat Security Bypass and Denial of Service Vulnerabilities November 6, 2012 - 6:00am Addthis PROBLEM: Apache Tomcat Security Bypass and Denial of Service Vulnerabilities PLATFORM: Apache Tomcat 5.x Apache Tomcat 6.x Apache Tomcat 7.x ABSTRACT: Two vulnerabilities were reported in Apache Tomcat REFERENCE LINKS: Apache.org Apache Tomcat Denial of Service Apache Tomcat DIGEST authentication weaknesses Secunia Advisory SA51138 CVE-2012-2733 CVE-2012-3439 IMPACT ASSESSMENT: Medium DISCUSSION: A weakness and a vulnerability have been reported in Apache Tomcat, which can be exploited by malicious people to bypass certain security restrictions and cause a DoS (Denial of Service). 1) An error within the "parseHeaders()" function

166

DEVELOPMENT OF A CANDLE FILTER FAILURE SAFEGUARD DEVICE  

SciTech Connect

The full-flow mechanical safeguard device (FFMSGD) has been developed under contract to the National Energy Technology Laboratory (NETL) to address problems with the reliability of ceramic candle filter elements installed on high-temperature, high-pressure (HTHP) Hot Gas Cleanup (HGCU) filters. Although systems candle filters are expected to perform satisfactorily when in good operating condition, the failure of even a single filter element can increase the filter system outlet dust loading enough to potentially damage gas turbine blades, contaminate other downstream processes, and limit the availability of the power system. Filter failure safeguard devices that are installed on each individual candle filter element are envisioned as a guarantee of a candle filter system's ability to withstand some number of element failures and continue operation without these negative consequences. The intention of the FFMSGD is to provide this guarantee without incurring any significant pressure drop penalty or constraining the filter system's reverse-pulse cleaning procedures. The FFMSGD provides a clear flow path for filtered and reverse-flow cleaning gases when its filter element is intact, and activates to provide a positive mechanical seal against gas flow in either direction when its filter element breaks or fails. This activation is induced by the increase in the flow rate of gas through the device in event of filter failure. The FFMSGD is designed to be easily removed and reconditioned when the filter system is taken off line for routine maintenance. This report is intended to be issued with a companion appendix. As instructed in Section J.12 of Contract No. DE-AC26-99FT40678, all the restricted, proprietary, and patentable information (not yet disclosed through the patent application process) related to the FFMSGD and its evaluation under this contract has been included only in the appendix. This Final Report, which is available to the public, contains background information and general descriptions of the operating principles of the FFMSGD. This report also describes the results of various evaluations of the device at room temperature and in HTHP environments. This Final Report also includes discussions of commercialization issues. For clarity and completeness, all of the information contained in this Final Report has also been included in the appendix.

Todd R. Snyder

2002-03-29T23:59:59.000Z

167

EVALUATION OF ALTERNATIVE FILTER MEDIA FOR THE ROTARY MICROFILTER  

SciTech Connect

SRS is currently developing and testing several processes to treat high level radioactive liquid waste. These processes include the Integrated Salt Disposition Process (ISDP), the Salt Waste Processing Facility (SWPF), and the Small Column Ion Exchange Process (SCIX). Each of these processes has a solid-liquid separation process that limits its throughput. SRNL researchers identified and tested the rotary microfilter as a technology to increase solid-liquid separation throughput. The testing showed significant improvement in filter flux with the rotary microfilter over the baseline crossflow filter (i.e., 2.5-6.5X during scoping tests, as much as 10X in actual waste tests, and approximately 3X in pilot-scale tests). SRNL received funding from DOE EM-21, and subsequently DOE EM-31 to develop the rotary microfilter for high level radioactive service. The work has included upgrading the rotary microfilter for radioactive service, testing with simulated SRS waste streams, and testing it with simulated Hanford waste streams. While the filtration rate is better than that obtained during testing of crossflow filters, the authors believe the rotary microfilter throughput can be improved by using a better filter membrane. The rotary microfilter membrane is made of stainless steel (Pall PMM050). Previous testing, funded by DOE EM-21, showed that asymmetric filters composed of a ceramic membrane on top of a stainless steel support produced higher filter flux than 100% stainless steel symmetric filters in crossflow filter tests. In that testing, the Pall Accusep and Graver filters produced 13-21% larger filter flux than the baseline 0.1 {micro}m Mott filter. While the improvement in flux is not as dramatic as the improvement of the rotary filter over a crossflow filter, a 13-21% increase could reduce the lifetime of a 30 year process by 4-6 years, with significant cost savings. Subsequent rotary filter testing showed the Pall PMM050 stainless steel filter membrane produced higher flux than the Mott filter media in bench-scale and pilot-scale testing. The Accusep and Graver filter media were not evaluated in that testing, because they are not available as flat sheets. The Accusep filter was developed at ORNL and licensed to Pall Corporation. This filter has a stainless steel support structure with a zirconium oxide ceramic membrane. The pore size is 0.1 {micro}m absolute. The Graver filter has a stainless steel support structure with a titanium dioxide ceramic membrane. The pore size is 0.07 {micro}m absolute. SRNL and ORNL are working together to develop filter media similar to the Accusep and Graver media, and to test them in a bench-scale filtration apparatus to attempt to improve the throughput of the rotary microfilter. This report describes the effort.

Poirier, M.; Herman, D.; Bhave, R.

2011-09-13T23:59:59.000Z

168

TESTING OF THE SECOND GENERATION SPINTEK ROTARY FILTER -11357  

SciTech Connect

The SpinTek rotary microfilter has been developed under the Department of Energy (DOE) Office of Environmental Management (EM) for the purpose of deployment in radioactive service in the DOE complex. The unit that was fabricated and tested is the second generation of the filter that incorporates recommended improvements from previous testing. The completion of this test satisfied a key milestone for the EM technology development program and technology readiness for deployment by Savannah River Remediation in the Small Column Ion Exchange and Sludge Washing processes at the Savannah River Site (SRS). The Savannah River National Laboratory (SRNL) contracted SpinTek Filtration to fabricate a full scale 25 disk rotary filter and perform a 1000 hour endurance test with a simulated SRS sludge. Over 1500 hours of operation have been completed with the filter. SpinTek Filtration fabricated a prototypic 25 disk rotary filter including updates to manufacturing tolerances, an updated design to the rotary joint, improved cooling to the bottom journal, decreases in disk and filter shaft hydraulic resistances. The filter disks were fabricated with 0.5 {micro} pore size, sintered-metal filter media manufactured by Pall Corporation (M050). After fabrication was complete, the filter passed acceptance tests demonstrating rejection of solids and clean water flux with a 50% improvement over the previous filters. Once the acceptance test was complete, a 1000 hour endurance test was initiated simulating a sludge washing process. The test used a simulated SRS Sludge Batch 6 recipe. The insoluble solids started at 5 wt% and were raised to 10 and 15 wt% insoluble solids to simulate the concentration of a large volume tank. The filter system was automated and set up for 24 hour unattended operation. To facilitate this, process control logic was written to operate the filter. During the development it was demonstrated that the method of starting and stopping the filter can affect the build up of filter cake on the disks and therefore the performance of the filter. The filter performed well with the simulant. Very little drop in production was noticed between the 5 and 10 wt% insoluble solids feed. Increasing to 15 wt% had a more pronounced impact due to the rheology of the feed. Acid cleaning was used to clean the filter disks in-situ and restore filtration rate to almost 90% of the initial clean disk rate. Eighty liters of 0.2 M nitric acid in conjunction with water rinses were used to clean the filter in less than 2 hours. Filter testing was completed after 1000 hours of operation were performed on the final filter assembly configuration. The total run time for the testing was over 1500 hours. At the end of the test, the sludge washing was performed successfully from approximately 5.6 M to less than 1 M sodium.

Herman, D.; Poirier, M.; Fowley, M.; Keefer, M.; Huff, T.

2011-02-02T23:59:59.000Z

169

Coated x-ray filters  

DOE Patents (OSTI)

A radiation filter for filtering radiation beams of wavelengths within a preselected range of wavelengths comprises a radiation transmissive substrate and an attenuating layer deposited on the substrate. The attenuating layer may be deposited by a sputtering process or a vacuum process. Beryllium may be used as the radiation transmissive substrate. In addition, a second radiation filter comprises an attenuating layer interposed between a pair of radiation transmissive layers. 4 figs.

Steinmeyer, P.A.

1991-02-07T23:59:59.000Z

170

Coated x-ray filters  

DOE Patents (OSTI)

A radiation filter for filtering radiation beams of wavelengths within a preselected range of wavelengths comprises a radiation transmissive substrate and an attenuating layer deposited on the substrate. The attenuating layer may be deposited by a sputtering process or a vacuum process. Beryllium may be used as the radiation transmissive substrate. In addition, a second radiation filter comprises an attenuating layer interposed between a pair of radiation transmissive layers.

Steinmeyer, Peter A. (Farmington, NM)

1992-11-24T23:59:59.000Z

171

Study of Compact Tunable Filters Using Negative Refractive Index Transmission Lines  

E-Print Network (OSTI)

Today's microwave circuits, whether for communication, radar, or testing systems, need compact tunable microwave filters. Since different microwave circuit applications have radically different size, power, insertion loss, rejection, vibration, and thermal requirements, new filter technologies with different balances between these requirements are always desirable. Negative Refractive Index (NRI) transmission media was discovered 10 years ago with the unique property of negative phase propagation. A literature review was conducted to identify potential NRI methods for filters and other devices, but no NRI tunable filters were found. To address this gap, a family of tunable NRI bandpass filters was simulated and constructed successfully using end-coupled zeroth order resonators. Tuning was accomplished by controlling the negative phase length of the NRI sections with varactors. The resulting L-band filters exhibited a 25-40 percent tunable range, no higher order resonances, and required only one fourth the length of a coupled-line filter constructed from traditional 180 degree microstrip resonators.

Lewis, Brian Patrick

2011-05-01T23:59:59.000Z

172

Explaining Collaborative Filtering Recommendations  

E-Print Network (OSTI)

Automated collaborative filtering (ACF) systems predict a person's affinity for items or information by connecting that person's recorded interests with the recorded interests of a community of people and sharing ratings between likeminded persons. However, current recommender systems are black boxes, providing no transparency into the working of the recommendation. Explanations provide that transparency, exposing the reasoning and data behind a recommendation. In this paper, we address explanation interfaces for ACF systems -- how they should be implemented and why they should be implemented. To explore how, we present a model for explanations based on the user's conceptual model of the recommendation process. We then present experimental results demonstrating what components of an explanation are the most compelling. To address why, we present experimental evidence that shows that providing explanations can improve the acceptance of ACF systems. We also describe some initial explor...

Jonathan Herlocker Joseph; Joseph A. Konstan; John Riedl

2000-01-01T23:59:59.000Z

173

Pre-test CFD Calculations for a Bypass Flow Standard Problem  

SciTech Connect

The bypass flow in a prismatic high temperature gas-cooled reactor (HTGR) is the flow that occurs between adjacent graphite blocks. Gaps exist between blocks due to variances in their manufacture and installation and because of the expansion and shrinkage of the blocks from heating and irradiation. Although the temperature of fuel compacts and graphite is sensitive to the presence of bypass flow, there is great uncertainty in the level and effects of the bypass flow. The Next Generation Nuclear Plant (NGNP) program at the Idaho National Laboratory has undertaken to produce experimental data of isothermal bypass flow between three adjacent graphite blocks. These data are intended to provide validation for computational fluid dynamic (CFD) analyses of the bypass flow. Such validation data sets are called Standard Problems in the nuclear safety analysis field. Details of the experimental apparatus as well as several pre-test calculations of the bypass flow are provided. Pre-test calculations are useful in examining the nature of the flow and to see if there are any problems associated with the flow and its measurement. The apparatus is designed to be able to provide three different gap widths in the vertical direction (the direction of the normal coolant flow) and two gap widths in the horizontal direction. It is expected that the vertical bypass flow will range from laminar to transitional to turbulent flow for the different gap widths that will be available.

Rich Johnson

2011-11-01T23:59:59.000Z

174

Dehumidification Without Re-heat Using Face and Bypass Dampers  

E-Print Network (OSTI)

Installations with chill water cooling, needing constant air volume and dehumidification, traditionally use a draw through air handling unit with a cooling coil and a re-heat coil. Dehumidification is achieved by overcooling the discharge air to wring out moisture and then reheating it back to the desired temperature. This method works well but at the added expense of over cooling plus re-heating. A properly controlled Face and Bypass unit can deliver the same air conditions by blending return air and cold deck air with no need for re-heat. This system uses only the amount of cooling energy needed to do the job and no re-heat energy, in some cases as much as 50% less energy than the re-heat method.

Warila, D. T.

1994-01-01T23:59:59.000Z

175

New pathway to bypass the 15O waiting point  

E-Print Network (OSTI)

We propose the sequential reaction process $^{15}$O($p$,$\\gamma)(\\beta^{+}$)$^{16}$O as a new pathway to bypass of the $^{15}$O waiting point. This exotic reaction is found to have a surprisingly high cross section, approximately 10$^{10}$ times higher than the $^{15}$O($p$,$\\beta^{+}$)$^{16}$O. These cross sections were calculated after precise measurements of energies and widths of the proton-unbound $^{16}$F low lying states, obtained using the H($^{15}$O,p)$^{15}$O reaction. The large $(p,\\gamma)(\\beta^{+})$ cross section can be understood to arise from the more efficient feeding of the low energy wing of the ground state resonance by the gamma decay. The implications of the new reaction in novae explosions and X-ray bursts are discussed.

I. Stefan; F. de Oliveira Santos; M. G. Pellegriti; G. Dumitru; J. C. Angélique; M. Angélique; E. Berthoumieux; A. Buta; R. Borcea; A. Coc; J. M. Daugas; T. Davinson; M. Fadil; S. Grévy; J. Kiener; A. Lefebvre-Schuhl; M. Lenhardt; M. Lewitowicz; F. Negoita; D. Pantelica; L. Perrot; O. Roig; M. G. Saint Laurent; I. Ray; O. Sorlin; M. Stanoiu; C. Stodel; V. Tatischeff; J. C. Thomas

2006-03-22T23:59:59.000Z

176

Development of By-Pass Blending Station System  

E-Print Network (OSTI)

A new building blending station system named by-pass blending station (BBS) has been developed to reduce building pump energy consumption in both district heating and cooling systems. Theoretical investigation demonstrated that the BBS can significantly reduce building pump power for a typical cooling system when constant water flow is maintained in the building side. When differential pressure reset is applied in the building side, more pump energy can be saved. The BBS also reduces the pump size and therefore results in lower initial system cost. A case study was also performed and demonstrated 42% of annual chilled water pump energy savings for constant building water flow, and 82% of annual chilled water pump savings for differential pressure resetting at Omaha, Nebraska.

Liu, M.; Barnes, D.; Bunz, K.; Rosenberry, N.

2003-01-01T23:59:59.000Z

177

Update on Novel Filter Development  

Science Conference Proceedings (OSTI)

Fabric filters (FFs) are highly effective particulate control devices installed at U.S. power plants to meet federal and state particulate emission requirements. This report describes FF operation at two coal-fired power plants, emphasizing tests of novel filter bag materials that may improve FF performance.

2009-02-26T23:59:59.000Z

178

Metallic Mesh Filter Used for Electromagnetic Shielding of Infrared Window  

Science Conference Proceedings (OSTI)

In order to meet anti-electromagnetism interference performance requirements of infrared window, a metallic mesh coating must be used on the infrared window. From the diffraction theory of grating and the equivalent circuit method, simplified expressions ... Keywords: stealth technology, electro-optical countermeasure, transparent conductive coating, metallic mesh filter, infrared window

Jia-Li Song, Xiao-Guo Feng

2012-07-01T23:59:59.000Z

179

Locating and producing bypassed oil: A U.S. DOE project update  

SciTech Connect

Tidelands Oil Production Co. is conducting a Class 3 near-term waterflood project supported partially by the US Dept. of Energy (USDOE) titled Increasing Waterflood Reserves in the Wilmington Oil Field Through Improved Reservoir Characterization and Reservoir Management. The project takes place across Fault Blocks 4 and 5 of the Wilmington field, Long Beach, California. The objective of this U.S. DOE demonstration project is to increase waterflood reserves in slope and basin clastic reservoirs through improved methods of identifying sands containing oil bypassed by a waterflood and exploiting this oil by recompleting existing idle wells. Specific objectives include identifying sands containing high remaining-oil saturation by use of a multiple acoustic cased-hole logging tool, determining geophysical parameters for interpretation of the acoustic data, demonstrating and gaining experience with a short-radius lateral recompletion, optimizing standard and steam recompletion techniques, generating a three-dimensional (3D) geologic model, and transferring the developed technologies and methods to other operators of slope and basin clastic reservoirs. The paper discusses results to date on characterization, reservoir engineering, deterministic modeling, multiple acoustic logging, and recompletions.

NONE

1997-09-01T23:59:59.000Z

180

Evaluation of a Stirling engine heater bypass with the NASA Lewis nodal-analysis performance code  

SciTech Connect

In support of the US Department of Energy's Stirling Engine Highway Vehicle Systems program, the NASA Lewis Research Center investigated whether bypassing the P-40 Stirling engine heater during regenerative cooling would improve the engine thermal efficiency. The investigation was accomplished by using the Lewis nodal-analysis Stirling engine computer model. Bypassing the P-40 Stirling engine heater at full power resulted in a rise in the indicated thermal efficiency from 40.6 to 41.0 percent. For the idealized (some losses not included) heater bypass that was analyzed, this benefit is not considered significant.

Sullivan, T.J.

1986-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Fuel Efficient Diesel Particulate Filter (DPF) Modeling and Development  

DOE Green Energy (OSTI)

The project described in this report seeks to promote effective diesel particulate filter technology with minimum fuel penalty by enhancing fundamental understanding of filtration mechanisms through targeted experiments and computer simulations. The overall backpressure of a filtration system depends upon complex interactions of particulate matter and ash with the microscopic pores in filter media. Better characterization of these phenomena is essential for exhaust system optimization. The acicular mullite (ACM) diesel particulate filter substrate is under continuing development by Dow Automotive. ACM is made up of long mullite crystals which intersect to form filter wall framework and protrude from the wall surface into the DPF channels. ACM filters have been demonstrated to effectively remove diesel exhaust particles while maintaining relatively low backpressure. Modeling approaches developed for more conventional ceramic filter materials, such as silicon carbide and cordierite, have been difficult to apply to ACM because of properties arising from its unique microstructure. Penetration of soot into the high-porosity region of projecting crystal structures leads to a somewhat extended depth filtration mode, but with less dramatic increases in pressure drop than are normally observed during depth filtration in cordierite or silicon carbide filters. Another consequence is greater contact between the soot and solid surfaces, which may enhance the action of some catalyst coatings in filter regeneration. The projecting crystals appear to provide a two-fold benefit for maintaining low backpressures during filter loading: they help prevent soot from being forced into the throats of pores in the lower porosity region of the filter wall, and they also tend to support the forming filter cake, resulting in lower average cake density and higher permeability. Other simulations suggest that soot deposits may also tend to form at the tips of projecting crystals due to the axial velocity component of exhaust moving down the filter inlet channel. Soot mass collected in this way would have a smaller impact on backpressure than soot forced into the flow restrictions deeper in the porous wall structure. This project has focused on the development of computational, analytical, and experimental techniques that are generally applicable to a wide variety of exhaust aftertreatment technologies. By helping to develop improved fundamental understanding pore-scale phenomena affecting filtration, soot oxidation, and NOX abatement, this cooperative research and development agreement (CRADA) has also assisted Dow Automotive in continuing development and commercialization of the ACM filter substrate. Over the course of this research project, ACM filters were successfully deployed on the Audi R10 TDI racecar which won the 24 Hours of LeMans endurance race in 2006, 2007, and 2008; and the 12 Hours of Sebring endurance race in 2006 and 2007. It would not have been possible for the R10 to compete in these traditionally gasoline-dominated events without reliable and effective exhaust particulate filtration. These successes demonstrated not only the performance of automotive diesel engines, but the efficacy of DPF technology as it was being deployed around the world to meet new emissions standards on consumer vehicles. During the course of this CRADA project, Dow Automotive commercialized their ACM DPF technology under the AERIFYTM DPF brand.

Stewart, Mark L.; Gallant, Thomas R.; Kim, Do Heui; Maupin, Gary D.; Zelenyuk, Alla

2010-08-01T23:59:59.000Z

182

Full-scale Up-Flo^® stormwater filter field performance verification tests.  

E-Print Network (OSTI)

??The Up-Flo® Filter is an innovative high-rate, small footprint, stormwater treatment device based on upward filtration technology. It was originally developed by environmental engineers at… (more)

Cai, Yezhao

2013-01-01T23:59:59.000Z

183

Macromodeling and demonstration of the LT6600 amplifier and lowpass filter  

E-Print Network (OSTI)

The goal of this thesis is to demonstrate the abilities of the Sevastopoulos-LaPorte active low-pass filter topology in Linear Technology Corporation's LT6600 integrated circuit (IC). The thesis is split into two parts, ...

Pei, Cheng-Wei, 1981-

2004-01-01T23:59:59.000Z

184

Flexible packet filtering: providing a rich toolbox  

Science Conference Proceedings (OSTI)

The BSD/OS IPFW packet filtering system is a well engineered, flexible kernel framework for filtering (accepting, rejecting, logging, or modifying) IP packets. IPFW uses the well understood, widely available Berkeley Packet Filter (BPF) system as the ...

Kurt J. Lidl; Deborah G. Lidl; Paul R. Borman

2002-02-01T23:59:59.000Z

185

Ground Clutter Canceling with a Regression Filter  

Science Conference Proceedings (OSTI)

This paper explores ground clutter filtering with a class of cancelers that use regression. Regression filters perform this task in a simple manner, resulting in similar or better performance than the fifth-order elliptic filter implemented in ...

Sebastián M. Torres; Dusan S. Zrnic

1999-10-01T23:59:59.000Z

186

Performance of ceramic membrane filters  

SciTech Connect

CeraMem Corp.`s ceramic-membrane coated, dead-end ceramic filters offer a promising alternative to ceramic candle filters providing long-term operational and reliability issues are resolved: regenerability of filter passages by back pulse cleaning, tolerance to alkali-containing combustion gas and thermal/chemical aging. ANL is responsible for analytical modeling of filtration and pulse cleaning operations, flow-through testing, and prediction of filter response to thermal cycling under realistic service conditions. A test apparatus was built to expose ceramic filter specimens to chemical environments simulating operation of pressurized fluidized bed and integrated gasification combined cycle plants. Four long-duration tests have been conducted in which 100-cpsi channel filters were exposed to ash collected downstream of the cyclone separator at the PFBC plant at Tidd. Results are discussed. Focus has now shifted to exposing the advanced candle filter specimens to reducing gas environments containing NaCl, H{sub 2}S, H{sub 2}O, and gasification ash.

Ahluwalia, R.K.; Im, K.H.; Geyer, H.K. [Argonne National Lab., IL (United States); Shelleman, D.L.; Tressler, R.E. [Pennsylvania State Univ., University Park, PA (United States)

1996-08-01T23:59:59.000Z

187

V-045: Adobe ColdFusion Lets Local Users Bypass Sandbox Restrictions |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

5: Adobe ColdFusion Lets Local Users Bypass Sandbox 5: Adobe ColdFusion Lets Local Users Bypass Sandbox Restrictions V-045: Adobe ColdFusion Lets Local Users Bypass Sandbox Restrictions December 12, 2012 - 2:00am Addthis PROBLEM: Adobe ColdFusion Lets Local Users Bypass Sandbox Restrictions PLATFORM: ColdFusion 10, 9.0.2, 9.0.1 and 9.0 for Windows, Macintosh and UNIX ABSTRACT: A vulnerability was reported in Adobe ColdFusion. REFERENCE LINKS: SecurityTracker Alert ID: 1027853 Adobe Vulnerability identifier: APSB12-26 CVE 2012-5675 IMPACT ASSESSMENT: High DISCUSSION: Adobe has released a security hotfix for ColdFusion 10 and earlier versions for Windows, Macintosh and UNIX. This hotfix resolves a vulnerability which could result in a sandbox permissions violation in a shared hosting environment. Adobe recommends users update their product installation using

188

U-247: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass 7: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass Authentication and Gain Administrative Access U-247: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass Authentication and Gain Administrative Access August 29, 2012 - 6:00am Addthis PROBLEM: EMC Cloud Tiering Appliance Flaw Lets Remote Users Bypass Authentication and Gain Administrative Access PLATFORM: EMC Cloud Tiering Appliance (CTA) 7.4 and prior EMC Cloud Tiering Appliance Virtual Edition (CTA/VE) 7.4 and prior EMC Cloud Tiering Appliance (CTA) 9.0 and prior EMC Cloud Tiering Appliance Virtual Edition (CTA/VE) 9.0 and prior ABSTRACT: A vulnerability was reported in EMC Cloud Tiering Appliance. reference LINKS: SecurityTracker Alert ID: 1027448 Bugtraq ID: 55250 EMC.com CVE-2012-2285 IMPACT ASSESSMENT:

189

V-216: Drupal Monster Menus Module Security Bypass and Script Insertion  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

216: Drupal Monster Menus Module Security Bypass and Script 216: Drupal Monster Menus Module Security Bypass and Script Insertion Vulnerabilities V-216: Drupal Monster Menus Module Security Bypass and Script Insertion Vulnerabilities August 12, 2013 - 6:00am Addthis PROBLEM: Two vulnerabilities have been reported in the Monster Menus module for Drupal PLATFORM: Drupal Monster Menus Module 6.x and 7.x ABSTRACT: The vulnerabilities can be exploited by malicious users to bypass certain security restrictions and conduct script insertion attacks. REFERENCE LINKS: Secunia Advisory SA54391 Drupal Security Advisory CVE-2013-4229 CVE-2013-4230 IMPACT ASSES SMENT: Medium DISCUSSION: 1) Input passed via the title when editing page settings is not properly sanitised before being edited the next time. This can be exploited to insert arbitrary HTML and script code, which will be executed in a user's

190

T-594: IBM solidDB Password Hash Authentication Bypass Vulnerability |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

94: IBM solidDB Password Hash Authentication Bypass 94: IBM solidDB Password Hash Authentication Bypass Vulnerability T-594: IBM solidDB Password Hash Authentication Bypass Vulnerability April 4, 2011 - 6:08am Addthis PROBLEM: A vulnerability has been reported in IBM solidDB, which can be exploited by malicious people to bypass certain security restrictions. PLATFORM: IBM solidDB 4.x - IBM solidDB 6.x ABSTRACT: This vulnerability could allow remote attackers to execute arbitrary code on vulnerable installations of IBM solidDB. Authentication is not required to exploit this vulnerability. REFERENCE LINKS: IBM Security Alert Secunia Advisory: SA44030 ZDI Advisory: ZDI-11-115 IBM solidDB Support IMPACT ASSESSMENT: Medium Discussion: The specific flaw exists within the solid.exe process which listens by default on TCP ports 1315, 1964 and 2315. The authentication protocol

191

U-188: MySQL User Login Security Bypass and Unspecified Vulnerability |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8: MySQL User Login Security Bypass and Unspecified 8: MySQL User Login Security Bypass and Unspecified Vulnerability U-188: MySQL User Login Security Bypass and Unspecified Vulnerability June 12, 2012 - 7:00am Addthis PROBLEM: A security issue and vulnerability have been reported in MySQL PLATFORM: MySQL 5.x ABSTRACT: An error when verifying authentication attempts can be exploited to bypass the authentication mechanism. Reference LINKS: Original Advisory CVE-2012-2122 Secunia Advisory 49409 IMPACT ASSESSMENT: High Discussion: Successful exploitation of this vulnerability requires MySQL to be built on a system with a library that allows "memcmp()" to return a value outside of the -128 through 127 range (e.g. sse-optimized glibc). NOTE: Vendor binaries are reportedly not affected. The security issue is reported in versions prior to 5.1.63 and 5.5.25.

192

V-197: Adobe ColdFusion 10 WebSockets Security Bypass Vulnerability |  

NLE Websites -- All DOE Office Websites (Extended Search)

7: Adobe ColdFusion 10 WebSockets Security Bypass Vulnerability 7: Adobe ColdFusion 10 WebSockets Security Bypass Vulnerability V-197: Adobe ColdFusion 10 WebSockets Security Bypass Vulnerability July 11, 2013 - 6:00am Addthis PROBLEM: A vulnerability has been reported in Adobe ColdFusion PLATFORM: The vulnerability is reported in version 10 for Windows, Macintosh, and Linux ABSTRACT: The vulnerability is caused due to an unspecified error and can be exploited to invoke public methods on ColdFusion Components (CFC) using WebSockets REFERENCE LINKS: Secunia Advisory SA54024 Adobe Security Bulletin APSB13-19 Stackoverflow.com CVE-2013-3350 IMPACT ASSESSMENT: High DISCUSSION: The hotfix resolves a vulnerability that could permit an attacker to invoke public methods on ColdFusion Components (CFC) using WebSockets IMPACT: Security Bypass

193

V-162: Apache Struts "ParameterInterceptor" Security Bypass Vulnerability |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2: Apache Struts "ParameterInterceptor" Security Bypass 2: Apache Struts "ParameterInterceptor" Security Bypass Vulnerability V-162: Apache Struts "ParameterInterceptor" Security Bypass Vulnerability May 23, 2013 - 6:00am Addthis PROBLEM: A vulnerability has been reported in Apache Struts PLATFORM: The vulnerability is reported in versions prior to 2.3.14.1 ABSTRACT: A vulnerability has been reported in Apache Struts, which can be exploited by malicious people to bypass certain security restrictions. REFERENCE LINKS: Secunia Advisory SA53495 Apache Struts Advisory S2-012 Apache Struts Advisory S2-013 CVE-2013-1965 CVE-2013-1966 IMPACT ASSESSMENT: High DISCUSSION: A request that included a specially crafted request parameter could be used to inject arbitrary OGNL code into the stack, afterward used as request

194

V-077: Barracuda SSL VPN Bug Lets Remote Users Bypass Authentication |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7: Barracuda SSL VPN Bug Lets Remote Users Bypass 7: Barracuda SSL VPN Bug Lets Remote Users Bypass Authentication V-077: Barracuda SSL VPN Bug Lets Remote Users Bypass Authentication January 25, 2013 - 6:00am Addthis PROBLEM: A vulnerability was reported in Barracuda SSL VPN. PLATFORM: The vulnerability has been verified to exist in Barracuda SSL VPN version 2.2.2.203 ABSTRACT: A remote user can gain administrative access to the target system. REFERENCE LINKS: SecurityTracker Alert ID: 1028039 Barracuda Networks Advisory IMPACT ASSESSMENT: High DISCUSSION: A remote user can set a specially crafted Java system property (via 'setSysProp.jsp') to bypass access restrictions and gain access to the API functionality. This can be exploited to download configuration files, download database dumps, shutdown the system, and set new administrative

195

Status of granular bed filter development program  

SciTech Connect

The objective of this project was to design and develop moving bed granular filters and ceramic candle filters for particulate control from combined cycle systems. Results are described.

Wilson, K.B.; Haas, J.C.; Prudhomme, J.

1995-11-01T23:59:59.000Z

196

Experimental and Analytic Study on the Core Bypass Flow in a Very High Temperature Reactor  

SciTech Connect

Core bypass flow has been one of key issues in the very high temperature reactor (VHTR) design for securing core thermal margins and achieving target temperatures at the core exit. The bypass flow in a prismatic VHTR core occurs through the control element holes and the radial and axial gaps between the graphite blocks for manufacturing and refueling tolerances. These gaps vary with the core life cycles because of the irradiation swelling/shrinkage characteristic of the graphite blocks such as fuel and reflector blocks, which are main components of a core's structure. Thus, the core bypass flow occurs in a complicated multidimensional way. The accurate prediction of this bypass flow and counter-measures to minimize it are thus of major importance in assuring core thermal margins and securing higher core efficiency. Even with this importance, there has not been much effort in quantifying and accurately modeling the effect of the core bypass flow. The main objectives of this project were to generate experimental data for validating the software to be used to calculate the bypass flow in a prismatic VHTR core, validate thermofluid analysis tools and their model improvements, and identify and assess measures for reducing the bypass flow. To achieve these objectives, tasks were defined to (1) design and construct experiments to generate validation data for software analysis tools, (2) determine the experimental conditions and define the measurement requirements and techniques, (3) generate and analyze the experimental data, (4) validate and improve the thermofluid analysis tools, and (5) identify measures to control the bypass flow and assess its performance in the experiment.

Richard Schultz

2012-04-01T23:59:59.000Z

197

Determination of filter-cake thicknesses from on-line flow measurements and gas/particle transport modeling  

SciTech Connect

The use of cylindrical candle filters to remove fine ({approx}0.005 mm) particles from hot ({approx}500- 900{degrees}C) gas streams currently is being developed for applications in advanced pressurized fluidized bed combustion (PFBC) and integrated gasification combined cycle (IGCC) technologies. Successfully deployed with hot-gas filtration, PFBC and IGCC technologies will allow the conversion of coal to electrical energy by direct passage of the filtered gases into non-ruggedized turbines and thus provide substantially greater conversion efficiencies with reduced environmental impacts. In the usual approach, one or more clusters of candle filters are suspended from a tubesheet in a pressurized (P {approx_lt}1 MPa) vessel into which hot gases and suspended particles enter, the gases pass through the walls of the cylindrical filters, and the filtered particles form a cake on the outside of each filter. The cake is then removed periodically by a backpulse of compressed air from inside the filter, which passes through the filter wall and filter cake. In various development or demonstration systems the thickness of the filter cake has proved to be an important, but unknown, process parameter. This paper describes a physical model for cake and pressure buildups between cleaning backpulses, and for longer term buildups of the ``baseline`` pressure drop, as caused by incomplete filter cleaning and/or re-entrainment. When combined with operating data and laboratory measurements of the cake porosity, the model may be used to calculate the (average) filter permeability, the filter-cake thickness and permeability, and the fraction of filter-cake left on the filter by the cleaning backpulse or re-entrained after the backpulse. When used for a variety of operating conditions (e.g., different coals, sorbents, temperatures, etc.), the model eventually may provide useful information on how the filter-cake properties depend on the various operating parameters.

Smith, D.H.; Powell, V. [USDOE Morgantown Energy Technology Center, WV (United States); Ibrahim, E. [Oak Ridge Inst. for Science and Education, TN (United States); Ferer, M. [West Virginia Univ., Morgantown, WV (United States). Dept. of Physics; Ahmadi, G. [National Research Council, Washington, DC (United States)

1996-12-31T23:59:59.000Z

198

V-057: eXtplorer "ext_find_user()" Authentication Bypass Vulnerability |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

7: eXtplorer "ext_find_user()" Authentication Bypass 7: eXtplorer "ext_find_user()" Authentication Bypass Vulnerability V-057: eXtplorer "ext_find_user()" Authentication Bypass Vulnerability December 28, 2012 - 6:00am Addthis PROBLEM: eXtplorer "ext_find_user()" Authentication Bypass Vulnerability PLATFORM: eXtplorer 2.x ABSTRACT: A vulnerability has been reported in eXtplorer, which can be exploited by malicious people to bypass certain security restrictions. REFERENCE LINKS: Secunia Advisory SA51636 eXtplorer 2.1.3 Security Release IMPACT ASSESSMENT: Medium DISCUSSION: eXtplorer was notified of a problem within the authentication system of eXtplorer Versions 2.1.2, 2.1.1, 2.1.0 and 2.1.0RC5 that have been found to be vulnerable to an authentication bypass bug. IMPACT: An error within the "ext_find_user()" function in users.php can be

199

Efficient filtering of composite events  

Science Conference Proceedings (OSTI)

Event Notification Services (ENS) are used in various applications such as remote monitoring and control, stock tickers, traffic control, or facility management. The performance issues of the filtering of primitive events has been widely studied. However, ...

Annika Hinze

2003-07-01T23:59:59.000Z

200

Kalman Filter–Based CMORPH  

Science Conference Proceedings (OSTI)

A Kalman filter (KF)-based Climate Prediction Center (CPC) morphing technique (CMORPH) algorithm is developed to integrate the passive microwave (PMW) precipitation estimates from low-Earth-orbit (LEO) satellites and infrared (IR) observations ...

Robert J. Joyce; Pingping Xie

2011-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

The Filtering of Meteorological Fields  

Science Conference Proceedings (OSTI)

A generalization of the popular Shapiro filters is described which allows the suppression of a broader band of frequencies near the sampling limit corresponding to two-grid-length waves. Applications to high-order finite difference models are ...

R. James Purser

1987-12-01T23:59:59.000Z

202

Ensemble Filtering for Nonlinear Dynamics  

Science Conference Proceedings (OSTI)

A method for data assimilation currently being developed is the ensemble Kalman filter. This method evolves the statistics of the system by computing an empirical ensemble of sample realizations and incorporates measurements by a linear ...

Sangil Kim; Gregory L. Eyink; Juan M. Restrepo; Francis J. Alexander; Gregory Johnson

2003-11-01T23:59:59.000Z

203

Technology Transfer: Available Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

Materials Biofuels Biofuels Biotechnology and Medecine Biotechnology & Medicine Chemistry Developing World Energy Efficient Technologies Energy Environmental Technologies...

204

Horizontal well taps bypassed Dundee oil in Crystal field, Mich.  

SciTech Connect

The Dundee formation (Middle Devonian) has yielded more oil than any other producing interval in Michigan. The Dundee trend, which forms an east-west band across the central Michigan basin, consists of 137 fields which together have yielded more than 350 million bbl of oil. The first commercial Dundee production was established at Mt. Pleasant field in 1928, and most Dundee fields were discovered and brought on production during the 1930s--40s. Wells in many of the fields had very high initial production (IP) rates. IPs in excess of 1,000 b/d of oil were common, with values as high as 9,000 b/d reported. These high flow rates, combined with a thin (10--30 ft) oil column and a strong water drive, resulted in water coning that left significant volumes of oil unrecovered in some fields. One such field, Crystal field in Montcalm County, is the focus of a US Department of energy (DOE) Class 2 Reservoir Demonstration Project designed to demonstrate that horizontal drilling can recover significant volumes of this bypassed oil. The paper describes the demonstration project, regional setting, and the history of the Crystal field.

Wood, J.R.; Allan, J.R.; Huntoon, J.E.; Pennington, W.D. [Michigan Technological Univ., Houghton, MI (United States); Harrison, W.B. III [Western Michigan Univ., Kalamazoo, MI (United States); Taylor, E.; Tester, C.J. [Cronus Development Corp., Traverse City, MI (United States)

1996-10-21T23:59:59.000Z

205

Formaldehyde emissions from ventilation filters under different relative  

NLE Websites -- All DOE Office Websites (Extended Search)

Formaldehyde emissions from ventilation filters under different relative Formaldehyde emissions from ventilation filters under different relative humidity conditions Title Formaldehyde emissions from ventilation filters under different relative humidity conditions Publication Type Journal Article Refereed Designation Refereed Year of Publication 2013 Authors Sidheswaran, Meera A., Wenhao Chen, Agatha Chang, Robert Miller, Sebastian Cohn, Douglas P. Sullivan, William J. Fisk, Kazukiyo Kumagai, and Hugo Destaillats Journal Environmental Science and Technology Date Published 04/18/2013 Abstract A method combining life cycle assessment (LCA) and real options analyses is developed to predict project environmental and financial performance over time, under market uncertainties and decision-making flexibility. The method is applied to examine alternative uses for oil sands coke, a carbonaceous byproduct of processing the unconventional petroleum found in northern Alberta, Canada. Under uncertainties in natural gas price and the imposition of a carbon price, our method identifies that selling the coke to China for electricity generation by integrated gasification combined cycle is

206

Designing Optimal Spectral Filters for Inverse Problems  

Science Conference Proceedings (OSTI)

Spectral filtering suppresses the amplification of errors when computing solutions to ill-posed inverse problems; however, selecting good regularization parameters is often expensive. In many applications, data are available from calibration experiments. ... Keywords: Bayes risk, Bayesian risk, Tikhonov, Wiener filter, empirical risk, filtering, ill-posed problem, image deblurring, machine learning, optimal design, optimal filtering, regularization, singular value decomposition, stochastic programming

Julianne Chung; Matthias Chung; Dianne P. O'Leary

2011-11-01T23:59:59.000Z

207

Water washable stainless steel HEPA filter  

DOE Patents (OSTI)

The invention is a high efficiency particulate (HEPA) filter apparatus and system, and method for assaying particulates. The HEPA filter provides for capture of 99.99% or greater of particulates from a gas stream, with collection of particulates on the surface of the filter media. The invention provides a filter system that can be cleaned and regenerated in situ.

Phillips, Terrance D. (617 Chestnut Ct., Aiken, SC 29803)

2001-01-01T23:59:59.000Z

208

Status of Westinghouse hot gas filters for coal and biomass power systems  

SciTech Connect

Several advanced, coal and biomass-based combustion turbine power generation technologies using fuels (IGCC, PFBC, Topping-PFBC, HIPPS) are currently under development and demonstration. A key developing technology in these power generation systems is the hot gas filter. These power generation technologies must utilize highly reliable and efficient hot gas filter systems if their full thermal efficiency and cost potential is to be realized. This paper reviews the recent test and design progress made by Westinghouse in the development and demonstration of hot gas ceramic barrier filters toward the goal of reliability. The objective of this work is to develop and qualify, through analysis and testing, practical hot gas ceramic barrier filter systems that meet the performance and operational requirements for these applications.

Newby, R.A.; Lippert, T.E.; Alvin, M.A.; Burck, G.J.; Sanjana, Z.N. [Westinghouse Electric Corp., Pittsburgh, PA (United States)

1999-07-01T23:59:59.000Z

209

Active dc filter for HVDC systems  

SciTech Connect

This article is a case history of the installation of active dc filters for high-performance, low-cost harmonics filtering at the Lindome converter station in the Konti-Skan 2 HVDC transmission link between Denmark and Sweden. The topics of the article include harmonics, interference, and filters, Lindome active dc filter, active dc filter design, digital signal processor, control scheme, protection and fault monitoring, and future applications.

Zhang, W. (Royal Inst. of Tech., Stockholm (Sweden)); Asplund, G.

1994-01-01T23:59:59.000Z

210

RAPID SEPARATION METHOD FOR ACTINIDES IN EMERGENCY AIR FILTER SAMPLES  

SciTech Connect

A new rapid method for the determination of actinides and strontium in air filter samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used in emergency response situations. The actinides and strontium in air filter method utilizes a rapid acid digestion method and a streamlined column separation process with stacked TEVA, TRU and Sr Resin cartridges. Vacuum box technology and rapid flow rates are used to reduce analytical time. Alpha emitters are prepared using cerium fluoride microprecipitation for counting by alpha spectrometry. The purified {sup 90}Sr fractions are mounted directly on planchets and counted by gas flow proportional counting. The method showed high chemical recoveries and effective removal of interferences. This new procedure was applied to emergency air filter samples received in the NRIP Emergency Response exercise administered by the National Institute for Standards and Technology (NIST) in April, 2009. The actinide and {sup 90}Sr in air filter results were reported in {approx}4 hours with excellent quality.

Maxwell, S.; Noyes, G.; Culligan, B.

2010-02-03T23:59:59.000Z

211

Design and Initial Development of Monolithic Cross-Flow Ceramic Hot-Gas Filters  

SciTech Connect

Advanced, coal-fueled, power generation systems utilizing pressurized fluidized bed combustion (PFBC) and integrated gasification combined cycle (IGCC) technologies are currently being developed for high-efficiency, low emissions, and low-cost power generation. In spite of the advantages of these promising technologies, the severe operating environment often leads to material degradation and loss of performance in the barrier filters used for particle entrapment. To address this problem, LoTEC Inc., and Oak Ridge National Laboratory are jointly designing and developing a monolithic cross-flow ceramic hot-gas filter. The filter concept involves a truly monolithic cross-flow design that is resistant to delamination, can be easily fabricated, and offers flexibility of geometry and material make-up. During Phase I of the program, a thermo-mechanical analysis was performed to determine how a cross-flow filter would respond both thermally and mechanically to a series of thermal and mechanical loads. The cross-flow filter mold was designed accordingly, and the materials selection was narrowed down to Ca{sub 0.5}Sr{sub 0.5}Zr{sub 4}P{sub 6}O{sub 24} (CS-50) and 2Al{sub 2}O{sub 3}-3SiO{sub 2} (mullite). A fabrication process was developed using gelcasting technology and monolithic cross-flow filters were fabricated. The program focuses on obtaining optimum filter permeability and testing the corrosion resistance of the candidate materials.

Barra, C.; Limaye, S.; Stinton, D.P.; Vaubert, V.M.

1999-06-06T23:59:59.000Z

212

Radiant zone heated particulate filter  

DOE Patents (OSTI)

A system includes a particulate matter (PM) filter including an upstream end for receiving exhaust gas and a downstream end. A radiant zoned heater includes N zones, where N is an integer greater than one, wherein each of the N zones includes M sub-zones, where M is an integer greater than or equal to one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones, restricts exhaust gas flow in a portion of the PM filter that corresponds to the selected one of the N zones, and deactivates non-selected ones of the N zones.

Gonze, Eugene V [Pinckney, MI

2011-12-27T23:59:59.000Z

213

Westinghouse advanced particle filter system  

SciTech Connect

Integrated Gasification Combined Cycles (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) are being developed and demonstrated for commercial, power generation application. Hot gas particulate filters are key components for the successful implementation of IGCC and PFBC in power generation gas turbine cycles. The objective of this work is to develop and qualify through analysis and testing a practical hot gas ceramic barrier filter system that meets the performance and operational requirements of PFBC and IGCC systems. This paper updates the assessment of the Westinghouse hot gas filter design based on ongoing testing and analysis. Results are summarized from recent computational fluid dynamics modeling of the plenum flow during back pulse, analysis of candle stressing under cleaning and process transient conditions and testing and analysis to evaluate potential flow induced candle vibration.

Lippert, T.E.; Bruck, G.J.; Sanjana, Z.N.; Newby, R.A.

1994-10-01T23:59:59.000Z

214

Robust Ensemble Filtering and Its Relation to Covariance Inflation in the Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

A robust ensemble filtering scheme based on the H? filtering theory is proposed. The optimal H? filter is derived by minimizing the supremum (or maximum) of a predefined cost function, a criterion different from the minimum variance used in the ...

Xiaodong Luo; Ibrahim Hoteit

2011-12-01T23:59:59.000Z

215

Particle Kalman Filtering: A Nonlinear Bayesian Framework for Ensemble Kalman Filters  

Science Conference Proceedings (OSTI)

This paper investigates an approximation scheme of the optimal nonlinear Bayesian filter based on the Gaussian mixture representation of the state probability distribution function. The resulting filter is similar to the particle filter, but is ...

Ibrahim Hoteit; Xiaodong Luo; Dinh-Tuan Pham

2012-02-01T23:59:59.000Z

216

Measurements of filter-cake properties  

SciTech Connect

The Pressurized Fluidized-Bed Combustion (PFBC) and Integrated Gasification Combined Cycle (IGCC) programs of the U.S. Department of Energy require filtration, at temperatures from about 600 to 900 {degrees}C, of fine particles of coal ash, char, or spent and unreacted sorbent from hot-gas streams. Achieving acceptable filter lifetimes requires solutions to or avoidance of, such problems as incomplete filter cleaning, re-entrainment (i.e., re-filtration) of particles from filter cleaning, and bridging of filter cake between adjacent filters. These and other potential problems may arise from the materials properties of filter cakes, from the filter-bank design, and from the mechanisms of filter cleaning. Avoiding re-entrainment requires that some bonding and agglomeration of particles occur in the cakes (so that the agglomerates from filter cleaning are too large to be re-entrained), but excessive agglomeration can produce poor cleaning or bridging. For both PFBC and IGCC applications, we can form filter cakes at process temperatures, gas compositions, and gas flow rates, and measure the gas-phase permeabilities, porosities, tensile strengths, and deformation coefficients of these filter cakes to determine their dependencies on temperature, reaction time, gas composition, particle compositions, and particle size distributions. Filter-cake shear strengths and flow factors can be measured for powders ``as received,`` for filter cakes that we have heated to process temperatures, or for powders heated in reactive gases to simulate gas-solid reactions in process filter cakes.

Smith, D.H.; Grimm, U.; Haddad, G.J.

1996-12-31T23:59:59.000Z

217

ENGINEERING TECHNOLOGY Engineering Technology  

E-Print Network (OSTI)

, Mechatronics Technology, and Renewable Energy Technology. Career Opportunities Graduates of four origin, gender, age, marital status, sexual orientation, status as a Vietnam-era veteran, or disability

218

Technology Transfer: Available Technologies  

Please refer to the list of technologies below for licensing and research collaboration availability. If you can't find the technology you ...

219

A rigid porous filter and filtration method  

DOE Patents (OSTI)

The present invention involves a porous rigid filter comprising a plurality of concentric filtration elements having internal flow passages and forming external flow passages there between. The present invention also involves a pressure vessel containing the filter for the removal of particulate from high pressure particulate containing gases, and further involves a method for using the filter to remove such particulate. The present filter has the advantage of requiring fewer filter elements due to the high surface area- to-volume ratio provided by the filter, requires a reduced pressure vessel size, and exhibits enhanced mechanical design properties, improved cleaning properties, configuration options, modularity and ease of fabrication.

Chiang, Ta-Kuan; Straub, Douglas, Straub L.; Dennis, Richard A.

1998-12-01T23:59:59.000Z

220

V-234: EMC RSA Archer GRC Open Redirection Weakness and Security Bypass  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4: EMC RSA Archer GRC Open Redirection Weakness and Security 4: EMC RSA Archer GRC Open Redirection Weakness and Security Bypass Security Issue V-234: EMC RSA Archer GRC Open Redirection Weakness and Security Bypass Security Issue September 4, 2013 - 6:00am Addthis PROBLEM: A weakness and a security issue have been reported in EMC RSA Archer GRC PLATFORM: EMC RSA Archer GRC 5.x ABSTRACT: This fixes multiple vulnerabilities, which can be exploited to bypass certain security restrictions and to conduct spoofing attacks REFERENCE LINKS: Secunia Advisory SA54717 SecurityTracker Alert ID 1028971 EMC Identifier: ESA-2013-057 CVE-2013-3276 CVE-2013-3277 IMPACT ASSESSMENT: Medium DISCUSSION: 1) The application does not properly restrict deactivated users. This can be exploited by deactivated users to login and gain access to otherwise

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

T-536: Cisco ASA Multiple Flaws Let Remote Users Deny Service and Bypass  

NLE Websites -- All DOE Office Websites (Extended Search)

36: Cisco ASA Multiple Flaws Let Remote Users Deny Service and 36: Cisco ASA Multiple Flaws Let Remote Users Deny Service and Bypass Security Controls T-536: Cisco ASA Multiple Flaws Let Remote Users Deny Service and Bypass Security Controls January 18, 2011 - 2:30pm Addthis PROBLEM: Cisco ASA Multiple Flaws Let Remote Users Deny Service and Bypass Security Controls. PLATFORM: Cisco 5500 Series Adaptive Security Appliances (ASA) ABSTRACT: Cisco ASA 5500 Series Adaptive Security Appliances are affected by multiple vulnerabilities. Affected versions of Cisco ASA Software vary depending on the specific vulnerability. Cisco ASA 5500 Series Adaptive Security Appliances may experience a TCP connection exhaustion condition (no new TCP connections are accepted) that can be triggered through the receipt of specific TCP segments during the

222

Recovery of bypassed oil in the Dundee Formation (Devonian) of the Michigan Basin using horizontal drains. Final report, April 28, 1994--December 31, 1997  

SciTech Connect

Total hydrocarbon production in the Michigan Basin has surpassed 1 billion barrels (Bbbls) and total unrecovered reserves are estimated at 1--2 BBbls. However, hydrocarbon production in Michigan has fallen from 35 MMbbls/yr in 1979 to about 10 MMbbls/yr in 1996. In an effort to slow this decline, a field demonstration project designed around using a horizontal well to recover bypassed oil was designed and carried out at Crystal Field in Montcalm County, MI. The project had two goals: to test the viability of using horizontal wells to recover bypassed oil from the Dundee Formation, and to characterize additional Dundee reservoirs (29) that are look alikes to the Crystal Field. As much as 85 percent of the oil known to exist in the Dundee Formation in the Michigan Basin remains in the ground as bypassed oil. Early production techniques in the 137 fields were poor, and the Dundee was at risk of being abandoned, leaving millions of barrels of oil behind. Crystal Field in Montcalm County, Michigan is a good example of a worn out field. Crystal Field was once a prolific producer which had been reduced to a handful of wells, the best of which produced only 5 barrels per day. The demonstration well drilled as a result of this project, however, has brought new life to the Crystal Field. Horizontal drilling is one of the most promising technologies available for oil production. The new well was completed successfully in October of 1995 and has been producing 100 barrels of oil per day, 20 times better than the best conventional well in the field.

Wood, J.R.; Pennington, W.D.

1998-09-01T23:59:59.000Z

223

Image separation using particle filters  

Science Conference Proceedings (OSTI)

In this work, we will analyze the problem of source separation in the case of superpositions of different source images, which need to be extracted from a set of noisy observations. This problem occurs, for example, in the field of astrophysics, where ... Keywords: Bayesian source separation, Image separation, Non-stationary noise, Particle filtering, Sequential Monte Carlo

Mauro Costagli; Ercan Engin Kuruo?lu

2007-09-01T23:59:59.000Z

224

Dependable filtering: Philosophy and realizations  

Science Conference Proceedings (OSTI)

Digital content production and distribution has radically changed our business models. An unprecedented volume of supply is now on offer, whetted by the demand of millions of users from all over the world. Since users cannot be expected to browse through ... Keywords: Collaborative filtering, Sybil attack, link analysis, profile injection, social networks

Matteo Dell'Amico; Licia Capra

2010-12-01T23:59:59.000Z

225

ADVANCED HOT GAS FILTER DEVELOPMENT  

SciTech Connect

This report describes the fabrication and testing of continuous fiber ceramic composite (CFCC) based hot gas filters. The fabrication approach utilized a modified filament winding method that combined both continuous and chopped fibers into a novel microstructure. The work was divided into five primary tasks. In the first task, a preliminary set of compositions was fabricated in the form of open end tubes and characterized. The results of this task were used to identify the most promising compositions for sub-scale filter element fabrication and testing. In addition to laboratory measurements of permeability and strength, exposure testing in a coal combustion environment was performed to asses the thermo-chemical stability of the CFCC materials. Four candidate compositions were fabricated into sub-scale filter elements with integral flange and a closed end. Following the 250 hour exposure test in a circulating fluid bed combustor, the retained strength ranged from 70 t 145 percent of the as-fabricated strength. The post-test samples exhibited non-catastrophic failure behavior in contrast to the brittle failure exhibited by monolithic materials. Filter fabrication development continued in a filter improvement and cost reduction task that resulted in an improved fiber architecture, the production of a net shape flange, and an improved low cost bond. These modifications were incorporated into the process and used to fabricate 50 full-sized filter elements for testing in demonstration facilities in Karhula, Finland and at the Power Systems Development Facility (PSDF) in Wilsonville, AL. After 581 hours of testing in the Karhula facility, the elements retained approximately 87 percent of their as-fabricated strength. In addition, mechanical response testing at Virginia Tech provided a further demonstration of the high level of strain tolerance of the vacuum wound filter elements. Additional testing in the M. W. Kellogg unit at the PSDF has accumulated over 1800 hours of coal firing at temperatures of 760 °C including a severe thermal upset that resulted in the failure of several monolithic oxide elements. No failures of any kind have been reported for the MTI CFCC elements in either of these test campaigns. Additional testing is planned at the M. W. Kellogg unit and Foster Wheeler unit at the PSDF over the next year in order to qualify for consideration for the Lakeland PCFB. Process scale-up issues have been identified and manufacturing plans are being evaluated to meet the needs of future demand.

RICHARD A. WAGNER

1998-09-04T23:59:59.000Z

226

EFFECTS OF GRAPHITE SURFACE ROUGHNESS ON BYPASS FLOW COMPUTATIONS FOR AN HTGR  

SciTech Connect

Bypass flow in a prismatic high temperature gas reactor (HTGR) occurs between graphite blocks as they sit side by side in the core. Bypass flow is not intentionally designed to occur in the reactor, but is present because of tolerances in manufacture, imperfect installation and expansion and shrinkage of the blocks from heating and irradiation. It is desired to increase the knowledge of the effects of such flow, which has been estimated to be as much as 20% of the total helium coolant flow. Computational fluid dynamic (CFD) simulations can provide estimates of the scale and impacts of bypass flow. Previous CFD calculations have examined the effects of bypass gap width, level and distribution of heat generation and effects of shrinkage. The present contribution examines the effects of graphite surface roughness on the bypass flow for different relative roughness factors on three gap widths. Such calculations should be validated using specific bypass flow measurements. While such experiments are currently underway for the specific reference prismatic HTGR design for the next generation nuclear plant (NGNP) program of the U. S. Dept. of Energy, the data are not yet available. To enhance confidence in the present calculations, wall shear stress and heat transfer results for several turbulence models and their associated wall treatments are first compared for flow in a single tube that is representative of a coolant channel in the prismatic HTGR core. The results are compared to published correlations for wall shear stress and Nusselt number in turbulent pipe flow. Turbulence models that perform well are then used to make bypass flow calculations in a symmetric onetwelfth sector of a prismatic block that includes bypass flow. The comparison of shear stress and Nusselt number results with published correlations constitutes a partial validation of the CFD model. Calculations are also compared to ones made previously using a different CFD code. Results indicate that increasing surface roughness increases the maximum fuel and helium temperatures as do increases in gap width. However, maximum coolant temperature variation due to increased gap width is not changed by surface roughness.

Rich Johnson; Yu-Hsin Tung; Hiroyuki Sato

2011-07-01T23:59:59.000Z

227

A Progressive Morphological Filter for Removing Nonground Measurements from Airborne LIDAR Data  

E-Print Network (OSTI)

Recent advances in airborne light detection and ranging (LIDAR) technology allow rapid and inexpensive measurements of topography over large areas. This technology is becoming a primary method for generating high-resolution digital terrain models (DTMs) that are essential to numerous applications such as flood modeling and landslide prediction. Airborne LIDAR systems usually return a three-dimensional cloud of point measurements from reflective objects scanned by the laser beneath the flight path. In order to generate a DTM, measurements from nonground features such as buildings, vehicles, and vegetation have to be classified and removed. In this paper, a progressive morphological filter was developed to detect nongroundLIDARmeasurements.By gradually increasingthe window size of the filter andusing elevation difference thresholds, themeasurements of vehicles, vegetation, and buildings are removed, while ground data are preserved. Datasets from mountainous and flat urbanized areas were selected to test the progressive morphological filter. The results show that the filter can remove most of the nonground points effectively.

Keqi Zhang; Shu-ching Chen; Dean Whitman; Mei-ling Shyu; Jianhua Yan; Chengcui Zhang; Student Member

2003-01-01T23:59:59.000Z

228

Koch Filter and DOW Teaming Profile  

NLE Websites -- All DOE Office Websites (Extended Search)

Koch Filter Corporation Dow Chemical Koch Filter Corporation Dow Chemical 4411-A Darien Street 2301 Brazosport Boulevard Houston, TX 77028 Freeport, TX 77541 Business: HVAC Filter Manufacturer Business: Chemical Manufacturer Bob Sheppard John Theile Regional Sales Manager Reliability Engineer Phone: 713-672-6550 Phone: 979-238-1894 Email: bobs@kochfilter.com Email: jptheile@dow.com Koch Filter saves Dow $156,000 by improving air flow to turbines Project Scope Koch Filter Corporation evaluated the turbine operation at a Dow Chemical facility. They determined that the gas turbine's air intake system was undersized and pre-filters had an initial resistance that was too high, causing the turbine to be "starved" for air. Koch replaced these filters with a better filter that

229

Obstacles to High-Dimensional Particle Filtering  

Science Conference Proceedings (OSTI)

Particle filters are ensemble-based assimilation schemes that, unlike the ensemble Kalman filter, employ a fully nonlinear and non-Gaussian analysis step to compute the probability distribution function (pdf) of a system’s state conditioned on a ...

Chris Snyder; Thomas Bengtsson; Peter Bickel; Jeff Anderson

2008-12-01T23:59:59.000Z

230

A Review of Recursive and Implicit Filters  

Science Conference Proceedings (OSTI)

Low- and high-pass traditional recursive and implicit filters are reviewed. Some similarities and differences between these two forms are illustrated. The use of recursive filters in signal processing is contrasted with the needs in meteorology. ...

William H. Raymond; Arthur Garder

1991-02-01T23:59:59.000Z

231

Filters for High Rate Pulse Processing  

E-Print Network (OSTI)

We introduce a filter-construction method for pulse processing that differs in two respects from that in standard optimal filtering, in which the average pulse shape and noise-power spectral density are combined to create a convolution filter for estimating pulse heights. First, the proposed filters are computed in the time domain, to avoid periodicity artifacts of the discrete Fourier transform, and second, orthogonality constraints are imposed on the filters, to reduce the filtering procedure's sensitivity to unknown baseline height and pulse tails. We analyze the proposed filters, predicting energy resolution under several scenarios, and apply the filters to high-rate pulse data from gamma-rays measured by a transition-edge-sensor microcalorimeter.

B. K. Alpert; R. D. Horansky; D. A. Bennett; W. B. Doriese; J. W. Fowler; A. S. Hoover; M. W. Rabin; J. N. Ullom

2012-12-07T23:59:59.000Z

232

A Filter Algorithm for Nonlinear Semidefinite Programming  

E-Print Network (OSTI)

SSDP using a merit function (called Han penalty function) and a line search strategy. Motivated by ... functions with penalty terms which adjustment can be problematic. The filter ..... Otherwise, when (?(xk), f(xk)) is entered to the filter, either at ...

233

Deep Frying: Chemistry, Nutrition and Practical ApplicationsChapter 19 Evaluation of Passive and Active Filter Media  

Science Conference Proceedings (OSTI)

Deep Frying: Chemistry, Nutrition and Practical Applications Chapter 19 Evaluation of Passive and Active Filter Media Food Science Health Nutrition Biochemistry eChapters Food Science & Technology Health - Nutrition - Biochemistry Pr

234

PLUTONIUM-URANIUM EXTRACTION (PUREX) FACILITY ALARACT DEMONSTRATION FOR FILTER HOUSING  

Science Conference Proceedings (OSTI)

This document presents an As Low As Reasonably Achievable Control Technology (ALARACT) demonstration for evaluating corrosion on the I-beam supporting filter housing No.9 for the 291-A-l emission unit of the Plutonium-Uranium Extraction (PUREX) Facility, located in the 200 East Area of the Hanford Site. The PUREX facility is currently in surveillance and maintenance mode. During a State of Washington, Department of Health (WDOH) 291-A-l emission unit inspection, a small amount of corrosion was observed at the base of a high-efficiency particulate air (HEPA) filter housing. A series of internal and external inspections identified the source of the corrosion material as oxidation of a small section of one of the carbon steel I-beams that provides support to the stainless steel filter housing. The inspections confirmed the corrosion is isolated to one I-beam support location and does not represent any compromise of the structural support or filter housing integrity. Further testing and inspections of the support beam corrosion and its cause were conducted but did not determine the cause. No definitive evidence was found to support any degradation of the housing. Although no degradation of the housing was found, a conservative approach will be implemented. The following actions will be taken: (1) The current operating filter housing No.9 will be removed from service. (2) The only remaining available filter housings (No.1, No.2, and No.3) will be placed in service. These filter housings have new HEPA filters fitted with stainless steel frames and faceguards which were installed in the spring of 2007. (3) Filter housings No.5 and No.10 will be put on standby as backups. To document the assessment of the unit, a draft ALARACT filter housing demonstration for the PUREX filter housing was prepared, and informally provided to WDOH on August 7, 2008. A follow up WDOH response to the draft ALARACT filter housing demonstration for the PUREX filter housing questioned whether deteriorated galvanized filter faceguards discovered during an internal filter housing inspection met American Society of Mechanical Engineers (ASME) AG-l or Military Specification (MIL) 51068 standards. The filter system was designed and installed prior to the issuance of AG-l, February 1986; however, MIL 51068 did require galvanized faceguards. The faceguards are not necessary for filtration or structural purposes; it is concluded that the system is in compliance with the intent of the applicable standard. Appendix B provides supporting information to address this issue.

LEBARON GJ

2008-11-25T23:59:59.000Z

235

Diesel exhaust filter uses steel wool  

SciTech Connect

Researchers are experimenting with a diesel exhaust filter which can use either steel wool or wire mesh as the filter medium. By using alumina coated metal wool as the filter matrix, submicron-sized particulate emissions may be recovered. The particulate trapping efficiency of this kind of filter depends on the amount of alumina applied to it, and its physical dimensions. Surface area, which is a function of all of these, correlates well with trapping efficiency.

Not Available

1982-04-01T23:59:59.000Z

236

Demonstration of Pulse-Jet Fabric Filters for Utility High-Sulfur Coal Applications  

Science Conference Proceedings (OSTI)

Pulse-jet fabric filters (PJFF) may be an effective, low-cost alternative to particulate control as they are typically 50% smaller than conventional utility baghouses filtering the same volume of flue gas. EPRI has initiated a program to demonstrate PJFF technology for domestic use. This report describes one of several research efforts to define the operating parameters of PJFFs with high-sulfur coal at EPRI's High-Sulfur Fabric Filter Pilot Plant at Gulf Power Company's Plant Scholz near Tallahassee, Fl...

1994-05-06T23:59:59.000Z

237

Cluster ensembles in collaborative filtering recommendation  

Science Conference Proceedings (OSTI)

Recommender systems, which recommend items of information that are likely to be of interest to the users, and filter out less favored data items, have been developed. Collaborative filtering is a widely used recommendation technique. It is based on the ... Keywords: Cluster ensembles, Collaborative filtering, Recommender systems, Self-organizing maps, k-Means

Chih-Fong Tsai; Chihli Hung

2012-04-01T23:59:59.000Z

238

Sensitivity filtering from a continuum mechanics perspective  

Science Conference Proceedings (OSTI)

In topology optimization filtering is a popular approach for preventing numerical instabilities. This short note shows that the well-known sensitivity filtering technique, that prevents checkerboards and ensures mesh-independent designs in density-based ... Keywords: Filtering, Regularization, Topology optimization

Ole Sigmund; Kurt Maute

2012-10-01T23:59:59.000Z

239

Development of Refrigerant Change Indicator and Dirty Air Filter Sensor  

Science Conference Proceedings (OSTI)

The most common problems affecting residential and light commercial heating, ventilation, and air-conditioning (HVAC) systems are slow refrigerant leaks and dirty air filters. Equipment users are usually not aware of a problem until most of the refrigerant has escaped or the air filter is clogged with dirt. While a dirty air filter can be detected with a technology based on the air pressure differential across the filter, such as a ''whistling'' indicator, it is not easy to incorporate this technology into existing HVAC diagnostic equipment. Oak Ridge National Laboratory is developing a low-cost, nonintrusive refrigerant charge indicator and dirty air filter detection sensor. The sensors, based on temperature measurements, will be inexpensive and easy to incorporate into existing heat pumps and air conditioners. The refrigerant charge indicator is based on the fact that when refrigerant starts to leak, the evaporator coil temperature starts to drop and the level of liquid subcooling drops. When the coil temperature or liquid subcooling drops below a preset reading, a signal, such as a yellow warning light, can be activated to warn the equipment user that the system is undercharged. A further drop of coil temperature or liquid subcooling below another preset reading would trigger a second warning signal, such as a red warning light, to warn the equipment user that the unit now detects a leak and immediate action should be taken. The warning light cannot be turned off until it is re-set by a refrigeration repairman. To detect clogged air filters, two additional temperature sensors can be applied, one each across the evaporator. When the air filter is accumulating buildup, the temperature differential across the evaporator will increase because of the reduced airflow. When the temperature differential reaches a pre-set reading, a signal will be sent to the equipment user that the air filter needs to be changed. A traditional refrigerant charge indicator requires intrusion into the system to measure the refrigerant high-side and low-side pressures. Once the pressures are known, based on the equipment's refrigerant charging chart? or in most cases, based on the technician's experience? the refrigerant charging status is determined. However, there is a catch: by the time a refrigeration technician is called, most of the refrigerant has already escaped into the atmosphere. The new technology provides a real-time warning so that when, say, 20% of the refrigerant has leaked, the equipment users will be warned, even though the equipment is still functioning properly at rated capacity. Temperature sensors are becoming very accurate and very low in cost, compared with pressure sensors. Using temperature sensors to detect refrigerant charge status is inherently nonintrusive, inexpensive, and accurate. With the addition of two temperature sensors for detecting dirty air filters, the capability of the diagnostic equipment is further enhanced with very little added cost. This report provides laboratory test data on the change of indoor coil refrigerant temperature and subcooling as a function of refrigerant charge for a 2-ton split heat pump system. The data can be used in designing the indicators for refrigerant loss and dirty air filter sensors.

Mei, V.

2003-06-24T23:59:59.000Z

240

Filter for a drill string  

DOE Patents (OSTI)

A filter for a drill string comprises a perforated receptacle having an open end and a perforated end and first and second mounting surfaces are adjacent the open end. A transmission element is disposed within each of the first and second mounting surfaces. A capacitor may modify electrical characteristics of an LC circuit that comprises the transmission elements. The respective transmission elements are in communication with each other and with a transmission network integrated into the drill string. The transmission elements may be inductive couplers, direct electrical contacts, or optical couplers. In some embodiments of the present invention, the filter comprises an electronic component. The electronic component may be selected from the group consisting of a sensor, a router, a power source, a clock source, a repeater, and an amplifier.

Hall, David R. (Provo, UT); Pixton, David S. (Lehi, UT); Briscoe, Michael (Lehi, UT); McPherson, James (Sandy, UT)

2007-12-04T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Mercury Oxidation via Catalytic Barrier Filters Phase II  

SciTech Connect

In 2004, the Department of Energy National Energy Technology Laboratory awarded the University of North Dakota a Phase II University Coal Research grant to explore the feasibility of using barrier filters coated with a catalyst to oxidize elemental mercury in coal combustion flue gas streams. Oxidized mercury is substantially easier to remove than elemental mercury. If successful, this technique has the potential to substantially reduce mercury control costs for those installations that already utilize baghouse barrier filters for particulate removal. Completed in 2004, Phase I of this project successfully met its objectives of screening and assessing the possible feasibility of using catalyst coated barrier filters for the oxidation of vapor phase elemental mercury in coal combustion generated flue gas streams. Completed in September 2007, Phase II of this project successfully met its three objectives. First, an effective coating method for a catalytic barrier filter was found. Second, the effects of a simulated flue gas on the catalysts in a bench-scale reactor were determined. Finally, the performance of the best catalyst was assessed using real flue gas generated by a 19 kW research combustor firing each of three separate coal types.

Wayne Seames; Michael Mann; Darrin Muggli; Jason Hrdlicka; Carol Horabik

2007-09-30T23:59:59.000Z

242

Integrated electric alternators/active filters  

E-Print Network (OSTI)

In response to energy crisis and power quality concerns, three different methodologies to integrate the concept of active filtering into the alternators are proposed. Wind energy, due to its free availability and its clean and renewable character, ranks as the most promising renewable energy resource that could play a key role in solving the worldwide energy crisis. An Integrated Doubly-fed Electric Alternator/Active filter (IDEA) for wind energy conversion systems is proposed. The proposed IDEA is capable of simultaneous capturing maximum power of wind energy and improving power quality, which are achieved by canceling the most significant and troublesome harmonics of the utility grid and power factor correction and reactive power compensation in the grid. The back-to-back current regulated power converters are employed to excite the rotor of IDEA. The control strategy of rotor-side power converter is based on position sensoreless field oriented control method with higher power density. Analysis and experimental results are presented to demonstrate the effectiveness of the proposed IDEA. In next step, an integrated synchronous machine/active filter is discussed. The proposed technology is essentially a rotating synchronous machine with suitable modification to its field excitation circuit to allow dc and ac excitations. It is shown that by controlling the ac excitation, the 5th and 7th harmonics currents of the utility are compensated. The proposed method is cost effective because it can be applied to existing standby generators in commercial and industrial plants with minimal modification to the excitation circuits. To boost the gain of harmonic compensatory, an advanced electric machine is proposed. An Asymmetric Airgap Concentrated Winding Synchronous Machine (AACWSM) with ac and dc excitation was designed and employed. It is shown that the AACWSM with its unique design, in addition to power generation capability, could be used to compensate the most dominant current harmonics of the utility. The proposed AACWSM can compensate for the 5th and 7th harmonics currents in the grid by controlling the ac field excitation. In addition, the 11th and 13th harmonics currents are also significantly reduced. This system can be used at medium and low voltages for generation or motoring mode of operation.

Abolhassani, Mehdi Towliat

2005-05-01T23:59:59.000Z

243

U-244: McAfee Email Gateway Lets Remote Users Bypass Authentication and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

4: McAfee Email Gateway Lets Remote Users Bypass Authentication 4: McAfee Email Gateway Lets Remote Users Bypass Authentication and Conduct Cross-Site Scripting and Directory Traversal Attacks U-244: McAfee Email Gateway Lets Remote Users Bypass Authentication and Conduct Cross-Site Scripting and Directory Traversal Attacks August 27, 2012 - 7:00am Addthis PROBLEM: McAfee Email Gateway Lets Remote Users Bypass Authentication and Conduct Cross-Site Scripting and Directory Traversal Attacks PLATFORM: McAfee Email Gateway (MEG) 7.0.0 and 7.0.1 (MEG 6.7.x is NOT affected.) McAfee Email and Web Security (EWS) 5.6 Patch 3 and earlier McAfee Email and Web Security (EWS) 5.5 Patch 6 and earlier ABSTRACT: Several vulnerabilities were reported in McAfee Email Gateway. reference LINKS: McAfee Security Bulletin ID: SB10026 SecurityTracker Alert ID: 1027444

244

V-190: ASUS RT-N66U Router AiCloud Security Bypass Security Issue |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

0: ASUS RT-N66U Router AiCloud Security Bypass Security Issue 0: ASUS RT-N66U Router AiCloud Security Bypass Security Issue V-190: ASUS RT-N66U Router AiCloud Security Bypass Security Issue July 2, 2013 - 12:38am Addthis PROBLEM: ASUS RT-N66U Router AiCloud Security Bypass Security Issue PLATFORM: ASUS RT-N66U Router firmware versions 3.0.0.4.270 and 3.0.0.4.354. ABSTRACT: A security issue in ASUS RT-N66U Router has been reported REFERENCE LINKS: Secunia Advisory SA53931 neohapsis IMPACT ASSESSMENT: Medium DISCUSSION: The security issue is caused due to the device not properly restricting access when processing certain HTTPS requests and can be exploited to gain access to otherwise restricted functionality and e.g. disclose the contents of arbitrary files and directories. Successful exploitation requires the AiCloud web service to be enabled.

245

U-244: McAfee Email Gateway Lets Remote Users Bypass Authentication and  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

44: McAfee Email Gateway Lets Remote Users Bypass Authentication 44: McAfee Email Gateway Lets Remote Users Bypass Authentication and Conduct Cross-Site Scripting and Directory Traversal Attacks U-244: McAfee Email Gateway Lets Remote Users Bypass Authentication and Conduct Cross-Site Scripting and Directory Traversal Attacks August 27, 2012 - 7:00am Addthis PROBLEM: McAfee Email Gateway Lets Remote Users Bypass Authentication and Conduct Cross-Site Scripting and Directory Traversal Attacks PLATFORM: McAfee Email Gateway (MEG) 7.0.0 and 7.0.1 (MEG 6.7.x is NOT affected.) McAfee Email and Web Security (EWS) 5.6 Patch 3 and earlier McAfee Email and Web Security (EWS) 5.5 Patch 6 and earlier ABSTRACT: Several vulnerabilities were reported in McAfee Email Gateway. reference LINKS: McAfee Security Bulletin ID: SB10026 SecurityTracker Alert ID: 1027444

246

Brief paper: Output tracking of continuous bioreactors through recirculation and by-pass  

Science Conference Proceedings (OSTI)

In this paper, we propose to regulate the output of an auto-catalytic bioprocess (a biological process associated with a growth of a micro-organism) by means of a recirculation loop and by-pass. We give conditions on the volume of the reactor and the ... Keywords: Continuous bioreactor, Nonlinear control design, Output regulation, Recirculation loop

Jérôme Harmand; Alain Rapaport; Frédéric Mazenc

2006-06-01T23:59:59.000Z

247

Westinghouse Advanced Particle Filter System  

SciTech Connect

Integrated Gasification Combined Cycles (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) are being developed and demonstrated for commercial, power generation application. Hot gas particulate filters are key components for the successful implementation of IGCC and PFBC in power generation gas turbine cycles. The objective of this work is to develop and qualify through analysis and testing a practical hot gas ceramic barrier filter system that meets the performance and operational requirements of PFBC and IGCC systems. This paper reports on the development and status of testing of the Westinghouse Advanced Hot Gas Particle Filter (W-APF) including: W-APF integrated operation with the American Electric Power, 70 MW PFBC clean coal facility--approximately 6000 test hours completed; approximately 2500 hours of testing at the Hans Ahlstrom 10 MW PCFB facility located in Karhula, Finland; over 700 hours of operation at the Foster Wheeler 2 MW 2nd generation PFBC facility located in Livingston, New Jersey; status of Westinghouse HGF supply for the DOE Southern Company Services Power System Development Facility (PSDF) located in Wilsonville, Alabama; the status of the Westinghouse development and testing of HGF`s for Biomass Power Generation; and the status of the design and supply of the HGF unit for the 95 MW Pinon Pine IGCC Clean Coal Demonstration.

Lippert, T.E.; Bruck, G.J.; Sanjana, Z.N.; Newby, R.A.; Bachovchin, D.M. [Westinghouse Electric Corp., Pittsburgh, PA (United States). Science and Technology Center

1996-12-31T23:59:59.000Z

248

Technology Search  

home \\ technologies \\ search. Technologies: Ready-to-Sign Licenses: Software: Patents: Technology Search. ... Operated by Lawrence Livermore National Security, LLC, ...

249

A SINGLE-PARAMETER ADAPTIVE COMB FILTER  

E-Print Network (OSTI)

The study is concerned with a single-parameter adaptive comb filter (ACF), a multi-notch filter with periodically located nulls. The filter is suggested to retrieve a waveform modeled by superposition of harmonics, in particular, periodic non-sinusoidal signal. Using trigonometric constraints between the signal fundamental frequency and over tones results in a non-linear estimation problem. In the present study, the parameter adjustment relies on the extended Kalman filter scheme. Particularly, the 2, 3 and 4 notch ACF are derived and tested under different conditions. Given a multi-tone scenario, the ACF significantly outperforms common adaptive multi-notch filter.

Single-Parameter Adaptive Comb; Naum G. Chernoguz

2001-01-01T23:59:59.000Z

250

Building Technologies Office: Emerging Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

Emerging Technologies Emerging Technologies Printable Version Share this resource Send a link to Building Technologies Office: Emerging Technologies to someone by E-mail Share Building Technologies Office: Emerging Technologies on Facebook Tweet about Building Technologies Office: Emerging Technologies on Twitter Bookmark Building Technologies Office: Emerging Technologies on Google Bookmark Building Technologies Office: Emerging Technologies on Delicious Rank Building Technologies Office: Emerging Technologies on Digg Find More places to share Building Technologies Office: Emerging Technologies on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Technology Research, Standards, & Codes Popular Links Success Stories Previous Next Lighten Energy Loads with System Design.

251

Hybrid Plasma Reactor/Filter for Transportable Collective Protection Systems  

SciTech Connect

Pacific Northwest National Laboratory (PNNL) has performed an assessment of a Hybrid Plasma/Filter system as an alternative to conventional methods for collective protection. The key premise of the hybrid system is to couple a nonthermal plasma (NTP) reactor with reactive adsorption to provide a broader envelope of protection than can be provided through a single-solution approach. The first step uses highly reactive species (e.g. oxygen radicals, hydroxyl radicals, etc.) created in a nonthermal plasma (NTP) reactor to destroy the majority (~75% - 90%) of an incoming threat. Following the NTP reactor an O3 reactor/filter uses the O3 created in the NTP reactor to further destroy the remaining organic materials. This report summarizes the laboratory development of the Hybrid Plasma Reactor/Filter to protect against a ‘worst-case’ simulant, methyl bromide (CH3Br), and presents a preliminary engineering assessment of the technology to Joint Expeditionary Collective Protection performance specifications for chemical vapor air purification technologies.

Josephson, Gary B.; Tonkyn, Russell G.; Frye, J. G.; Riley, Brian J.; Rappe, Kenneth G.

2011-04-06T23:59:59.000Z

252

Filter for isotopic alteration of mercury vapor  

DOE Green Energy (OSTI)

A filter for enriching the .sup.196 Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The .sup.196 Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter.

Grossman, Mark W. (Belmont, MA); George, William A. (Gloucestor, MA)

1989-01-01T23:59:59.000Z

253

Filter for isotopic alteration of mercury vapor  

DOE Patents (OSTI)

A filter is described for enriching the [sup 196]Hg content of mercury, including a reactor, a low pressure electric discharge lamp containing a fill of mercury and an inert gas. A filter is arranged concentrically around the lamp. The reactor is arranged around said filter, whereby radiation from said lamp passes through the filter and into said reactor. The lamp, the filter and the reactor are formed of quartz, and are transparent to ultraviolet light. The [sup 196]Hg concentration in the mercury fill is less than that which is present in naturally occurring mercury, that is, less than about 0.146 atomic weight percent. Hydrogen is also included in the fill and serves as a quenching gas in the filter, the hydrogen also serving to prevent disposition of a dark coating on the interior of the filter. 9 figs.

Grossman, M.W.; George, W.A.

1989-06-13T23:59:59.000Z

254

Ceramic fiber ceramic matrix filter development  

SciTech Connect

The objectives of this project were to develop a novel type of candle filter based on a ceramic fiber-ceramic matrix composite material, and to extend the development to full-size, 60-mm OD by 1-meter-long candle filters. The goal is to develop a ceramic filter suitable for use in a variety of fossil energy system environments such as integrated coal gasification combined cycles (IGCC), pressurized fluidized-bed combustion (PFBC), and other advanced coal combustion environments. Further, the ceramic fiber ceramic matrix composite filter, hereinafter referred to as the ceramic composite filter, was to be inherently crack resistant, a property not found in conventional monolithic ceramic candle filters, such as those fabricated from clay-bonded silicon carbide. Finally, the adequacy of the filters in the fossil energy system environments is to be proven through simulated and in-plant tests.

Judkins, R.R.; Stinton, D.P. [Oak Ridge National Lab., TN (United States); Smith, R.G.; Fischer, E.M. [3M Company, St. Paul, MN (United States)

1994-09-01T23:59:59.000Z

255

The development of a porous silicon nitride crossflow filter; Final report, September 1988--September 1992  

Science Conference Proceedings (OSTI)

This report summarizes the work performed in developing a permeable form of silicon nitride for application to ceramic crossflow filters for use in advanced coal-fired electric power plants. The program was sponsored by the Department of Energy Morgantown Energy Technology Center and consisted of a design analysis and material development phase and a filter manufacture and demonstration phase. The crossflow filter design and operating requirements were defined. A filter design meeting the requirements was developed and thermal and stress analyses were performed. Material development efforts focused initially on reaction-bonded silicon nitride material. This approach was not successful, and the materials effort was refocused on the development of a permeable form of sintered silicon nitride (SSN). This effort was successful. The SSN material was used for the second phase of the program, filter manufacture and evaluation. Four half-scale SAN filter modules were fabricated. Three of the modules were qualified for filter performance tests. Tests were performed on two of the three qualified modules in the High-Temperature, High-Pressure facility at the Westinghouse Science and Technology Center. The first module failed on test when it expanded into the clamping device, causing dust leakage through the filter. The second module performed well for a cumulative 150-hr test. It displayed excellent filtration capability during the test. The blowback pulse cleaning was highly effective, and the module apparently withstood the stresses induced by the periodic pulse cleaning. Testing of the module resumed, and when the flow of combustion gas through the filter was doubled, cracks developed and the test was concluded.

NONE

1992-09-01T23:59:59.000Z

256

The use of filtered bags to increase waste payload capacity  

DOE Green Energy (OSTI)

For the past few years, the Department of Energy has favored the direct disposal of low plutonium content residue materials from Rocky Flats rather than engage in expensive and time consuming plutonium recovery operations. One impediment to direct disposal has been the wattage limit imposed by the Waste Isolation Pilot Plant on hydrogenous materials such as combustibles and sludges. The issue of concern is the radiolytic generation and accumulation of hydrogen and other explosive gases in waste containers. The wattage limits that existed through 1996 restricted the amount of plutonium bearing hydrogenous materials that could be packaged in a WIPP bound waste drum to only a fraction of the capacity of a drum. Typically, only about one kilogram of combustible residue could be packaged in a waste drum before the wattage limit was exceeded resulting in an excessively large number of drums to be procured, stored, shipped, and interred. The Rocky Flats Environmental Technology Site has initiated the use of filtered plastic bags (called bag-out bags) used to remove transuranic waste materials from glove box lines. The bags contain small, disk like HEPA filters which are effective in containing radioactively contaminated particulate material but allow for the diffusion of hydrogen gas. Used in conjunction with filtered 55 gallon drums, filtered bag-out bags were pursued as a means to increase the allowable wattage limits for selected residue materials. In February 1997, the Nuclear Regulatory Commission approved the use of filtered bag-out bags for transuranic waste materials destined for WIPP. The concomitant increase in wattage limits now allows for approximately four times the payload per waste drum for wattage limited materials.

Dustin, D.F.; Thorp, D.T. [Safe Sites of Colorado, Golden, CO (United States); Rivera, M.A. [Los Alamos Technical Associates, Albuquerque, NM (United States)

1998-03-03T23:59:59.000Z

257

Method and apparatus for filtering gas with a moving granular filter bed  

DOE Patents (OSTI)

A method and apparatus for filtering gas (58) with a moving granular filter bed (48) involves moving a mass of particulate filter material (48) downwardly through a filter compartment (35); tangentially introducing gas into the compartment (54) to move in a cyclonic path downwardly around the moving filter material (48); diverting the cyclonic path (58) to a vertical path (62) to cause the gas to directly interface with the particulate filter material (48); thence causing the gas to move upwardly through the filter material (48) through a screened partition (24, 32) into a static upper compartment (22) of a filter compartment for exodus (56) of the gas which has passed through the particulate filter material (48).

Brown, Robert C. (Ames, IA); Wistrom, Corey (Ames, IA); Smeenk, Jerod L. (Ames, IA)

2007-12-18T23:59:59.000Z

258

Technology Alert List From the U.S. Department of State  

E-Print Network (OSTI)

and industry; these technologies are relatively common in many countries. Advanced biotechnology has "DOP-rated filters" (e.g., HEPA filters, ULPA filters) · Microencapsulation #12;· Aerosol sprayers) · Production of glass-lined steel reactors/vessels, pipes, flanges, and other equipment · Aerosol sprayers

Guenther, Frank

259

ADVANCED HOT GAS FILTER DEVELOPMENT  

SciTech Connect

Iron aluminide hot gas filters have been developed using powder metallurgy techniques to form seamless cylinders. Three alloys were short-term corrosion tested in simulated IGCC atmospheres with temperatures between 925 F and 1200 F with hydrogen sulfide concentrations ranging from 783 ppm{sub v} to 78,300 ppm{sub v}. Long-term testing was conducted for 1500 hours at 925 F with 78,300 ppm{sub v}. The FAS and FAL alloys were found to be corrosion resistant in the simulated environments. The FAS alloy has been commercialized.

Matthew R. June; John L. Hurley; Mark W. Johnson

1999-04-01T23:59:59.000Z

260

Technology Capabilities  

NLE Websites -- All DOE Office Websites (Extended Search)

Homeland Security & Defense Homeland Security & Defense Information Technology & Communications Information Technology & Communications Sensors, Electronics &...

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Widget:RRSectionFilter | Open Energy Information  

Open Energy Info (EERE)

RRSectionFilter RRSectionFilter Jump to: navigation, search This widget creates a filter tool, which will allow the user to filter the content displayed on the screen by RR Section region. It has been designed for use explicitly with the Geothermal Regulatory Roadmap home page. It is not designed for any other use. Parameters No paramteres Dependancies The Geothermal Regulatory Roadmap Sections page. Usage This Widget assumes the existence of HTML elements created by the Geothermal Regulatory Roadmap Sections page, and is called by that page using the following code: {{#Widget:RRSectionFilter}} Example For an example of this widget in use, please visit the page referenced above. (GRR/Sections) Retrieved from "http://en.openei.org/w/index.php?title=Widget:RRSectionFilter&oldid=65912

262

Two Wien Filter Spin Flipper  

SciTech Connect

A new 4pi spin manipulator composed of two Wien filters oriented orthogonally and separated by two solenoids has been installed at the CEBAF/Jefferson Lab photoinjector. The new spin manipulator is used to precisely set the electron spin direction at an experiment in any direction (in or out of plane of the accelerator) and provides the means to reverse, or flip, the helicity of the electron beam on a daily basis. This reversal is being employed to suppress systematic false asymmetries that can jeopardize challenging parity violation experiments that strive to measure increasingly small physics asymmetries [*,**,***]. The spin manipulator is part of the ultra-high vacuum polarized electron source beam line and has been successfully operated with 100keV and 130keV electron beam at high current (>100 microAmps). A unique feature of the device is that spin-flipping requires only the polarity of one solenoid magnet be changed. Performance characteristics of the Two Wien Filter Spin Flipper will be summarized.

Grames, J M; Benesch, J F; Clark, J; Hansknecht, J; Kazimi, R; Machie, D; Poelker, M; Stutzman, M L; Suleiman, R

2011-03-01T23:59:59.000Z

263

Diesel particulate filter with zoned resistive heater  

Science Conference Proceedings (OSTI)

A diesel particulate filter assembly comprises a diesel particulate filter (DPF) and a heater assembly. The DPF filters a particulate from exhaust produced by an engine. The heater assembly has a first metallic layer that is applied to the DPF, a resistive layer that is applied to the first metallic layer, and a second metallic layer that is applied to the resistive layer. The second metallic layer is etched to form a plurality of zones.

Gonze, Eugene V [Pinckney, MI

2011-03-08T23:59:59.000Z

264

DC side filters for multiterminal HVDC systems  

SciTech Connect

Multiterminal HVDC systems present challenges in the specification and design of suitable dc side filtering. This document examines the existing experience and addresses the particular technical problems posed by multiterminal systems. The filtering requirements of small taps are discussed, as is the potential use of active filters. Aspects of calculation and design are considered and recommendations made to guide the planners and designers of future multiterminal schemes.

Shore, N.L.; Adamson, K.; Bard, P. [and others

1996-10-01T23:59:59.000Z

265

Zone heated diesel particulate filter electrical connection  

DOE Patents (OSTI)

An electrical connection system for a particulate filter is provided. The system includes: a particulate filter (PF) disposed within an outer shell wherein the PF is segmented into a plurality of heating zones; an outer mat disposed between the particulate filter and the outer shell; an electrical connector coupled to the outer shell of the PF; and a plurality of printed circuit connections that extend along the outer surface of the PF from the electrical connector to the plurality of heating zones.

Gonze, Eugene V. (Pinckney, MI); Paratore, Jr., Michael J. (Howell, MI)

2010-03-30T23:59:59.000Z

266

Recovery of bypassed oil in the Dundee Formation using horizontal drains. Annual report, May 1, 1995--April 30, 1996  

SciTech Connect

The principal objective of this project is to demonstrate the feasibility and economics success of producing oil from abandoned or nearly abandoned fields in the Dundee Formation of Central Michigan using horizontal drilling technology. The project is a cooperative venture between Michigan Technological University (MTU), Western Michigan University (WMU), and Terra Energy (now Cronus Development Co.). During the fall of 1995, the demonstration well for this project, the TOW No. 1-3 well in Crystal Field, Montcalm County, Michigan, was completed in the Dundee Formation and for the first three months of operation produced 50 bbl/day oil with no water cut. Because surface facilities were inadequate to handle full production, the well was produced for 12 hrs/day and shut in for 12 hrs/day. In January, 1996, new surface Facilities were completed and production was raised to 100 bbl/day. Daily production has varied from about 75 to 100 BOPD since that time. To date, the well has produced over 10, 000 bbls. The water cut remains at 0% and pressure has been maintained at 1445 psi by an active water drive. If expectations are met, the well will pay out in less than 1 year and continue on production for at least 5 years. Cronus Development Co. is tentatively planning to drill three more horizontal wells in the Dundee in Crystal Field. Thus, the play concept we chose to test, that bypassed attic oil remained in the Dundee reservoir between wells that had been produced at excessively high flow rates and had coned water during primary production, appears to be correct, and the TOW No. 1-3 HD-1 well is now a scientific, and appears soon to become an economic, success.

Wood, J.R.

1996-04-30T23:59:59.000Z

267

Indestructible Ultra-filtration: Ceramic HEPA Filters  

High Efficiency Particulate Air (HEPA) filters are widely used commercial products to remove airborne particulates from a gas stream in a gas process ...

268

Continuous air monitor filter changeout apparatus  

DOE Patents (OSTI)

An apparatus and corresponding method for automatically changing out a filter cartridge in a continuous air monitor. The apparatus includes: a first container sized to hold filter cartridge replacements; a second container sized to hold used filter cartridges; a transport insert connectively attached to the first and second containers; a shuttle block, sized to hold the filter cartridges that is located within the transport insert; a transport driver mechanism means used to supply a motive force to move the shuttle block within the transport insert; and, a control means for operating the transport driver mechanism.

Rodgers, John C. (Santa Fe, NM)

2008-07-15T23:59:59.000Z

269

Microhydropower Conveyance and Filters | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

it is funneled through a series of components that control its flow and filter out debris. These components include the headrace, forebay, and water conveyance (or channel,...

270

Latest Filter Developments Increasing Existing Aluminium Smelter ...  

Science Conference Proceedings (OSTI)

Abstract Scope, With increasing electricity costs and falling metal commodity ... and the latest extension of Ad?Flow™ filter designs for even greater filtration ...

271

Matrix Inversion Lemma and Information Filter Mohammad Emtiyaz Khan  

E-Print Network (OSTI)

Matrix Inversion Lemma and Information Filter Mohammad Emtiyaz Khan Honeywell Technology Solutions) zt+1|t = (I -JtBT t )A-T t zt|t, Zt+1|t = (I -JtBT t )St (8) where St = A-T t P-1 t|t A-1 t and Jt = StBt(BT t StBt +Q-1 t )-1. The Kalman gain is given as Kt = Zt|tCT t R-1 t . For detailed proof see

Mitchell, Ian

272

Transmit Matched Filter And Transmit Wiener Filter For The Downlink Of FDD DS-CDMA Systems  

E-Print Network (OSTI)

We present space-time transmit filters for FDD DS-CDMA systems based on partial channel state information, i. e. we do not take into account the channel coefficients. Although the FDD transmit zero-forcing filter seems to be the most intuitive approach, we focus on the FDD transmit matched filter and the FDD transmit Wiener filter. Similarly to the respective receive filters and TDD transmit filters, the FDD matched filter maximizes the desired signal portion at the receiver and is optimum for low signal-to-noise-ratio scenarios, whereas the FDD transmit Wiener filter takes into account the noise power at the receiver and is therefore able to find an optimum trade-off between signal maximization and interference suppression. Additionally, we show that the FDD transmit matched filter is a type of Eigenbeamforming. The simulation results reveal the excellent performance of the two FDD transmit filters. The FDD transmit Wiener filter even outperforms the TDD transmit matched filter for high signalto -noise-ratio which is based on the instantaneous channel properties.

M. Joham; K. Kusume; W. Utschick; J. A. Nossek

2002-01-01T23:59:59.000Z

273

Vendor / Technology  

NLE Websites -- All DOE Office Websites (Extended Search)

Brake Assessment Tools Commercial Motor Vehicle Roadside Technology Corridor Safety Technology Showcase October 14, 2010 Commercial Motor Vehicle Roadside Technology Corridor...

274

Vendor / Technology  

NLE Websites -- All DOE Office Websites (Extended Search)

Brake-Related Research Commercial Motor Vehicle Roadside Technology Corridor Safety Technology Showcase October 14, 2010 Commercial Motor Vehicle Roadside Technology Corridor...

275

Faience Technology  

E-Print Network (OSTI)

by Joanne Hodges. Faience Technology, Nicholson, UEE 2009Egyptian materials and technology, ed. Paul T. Nicholson,Nicholson, 2009, Faience Technology. UEE. Full Citation:

Nicholson, Paul

2009-01-01T23:59:59.000Z

276

Active imaging system with Faraday filter  

DOE Patents (OSTI)

An active imaging system has a low to medium powered laser transmitter and receiver wherein the receiver includes a Faraday filter with an ultranarrow optical bandpass and a bare (nonintensified) CCD camera. The laser is locked in the vicinity of the passband of the Faraday filter. The system has high sensitivity to the laser illumination while eliminating solar background.

Snyder, J.J.

1993-04-13T23:59:59.000Z

277

A ZVS cycloconverter based series active filter  

Science Conference Proceedings (OSTI)

A new zero voltage switching (ZVS) series active filter (SAF) is proposed. The circuit includes a phase shift based PWM full-bridge inverter. A cycloconverter is used to control the polarity of output voltage pulses of mentioned inverter. Combination ... Keywords: series active filter, zero voltage switching

M. Tarafdar Haque; M. Sabahi

2006-03-01T23:59:59.000Z

278

A random map implementation of implicit filters  

Science Conference Proceedings (OSTI)

Implicit particle filters for data assimilation generate high-probability samples by representing each particle location as a separate function of a common reference variable. This representation requires that a certain underdetermined equation be solved ... Keywords: Data assimilation, Implicit sampling, Particle filters, Sequential Monte Carlo

Matthias Morzfeld; Xuemin Tu; Ethan Atkins; Alexandre J. Chorin

2012-02-01T23:59:59.000Z

279

Gaussian mixture CPHD filter with gating technique  

Science Conference Proceedings (OSTI)

Cardinalized probability hypothesis density (CPHD) filter provides more accurate estimates of target number than the probability hypothesis density (PHD) filter, and hence, also of the states of targets. This additional capability comes at the price ... Keywords: Finite sets statistics, Gating, Gaussian mixture, Probability hypothesis density, Target tracking

Hongjian Zhang; Zhongliang Jing; Shiqiang Hu

2009-08-01T23:59:59.000Z

280

Mayday: Distributed Filtering for Internet Services  

E-Print Network (OSTI)

Mayday is an architecture that combines overlay networks with lightweight packet filtering to defend against denial of service attacks. The overlay nodes perform client authentication and protocol verification, and then relay the requests to a protected server. The server is protected from outside attack by simple packet filtering rules that can be efficiently deployed even in backbone routers. Mayday generalizes

David G. Andersen

2003-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

STAIRS: Towards efficient full-text filtering and dissemination in DHT environments  

Science Conference Proceedings (OSTI)

Nowadays "live" content, such as weblog, wikipedia, and news, is ubiquitous in the Internet. Providing users with relevant content in a timely manner becomes a challenging problem. Differing from Web search technologies and RSS feeds/reader applications, ... Keywords: Content dissemination, Content filtering, DHT

Weixiong Rao; Lei Chen; Ada Wai-Chee Fu

2011-12-01T23:59:59.000Z

282

Design of efficient filter on liquid crystal polymer substrate for 5 GHz wireless LAN applications  

Science Conference Proceedings (OSTI)

Next generation wireless communications terminals will demand the use of advanced component integration processes and high density packaging technologies in order to reduce size and to increase performance. This paper presents high-density multilayer ... Keywords: LCP, MCM, RF front-end, bandpass filter, low noise amplifier, quality factor

Yasar Amin; Hannu Tenhunen; Habibullah Jamal; Li-Rong Zheng

2005-03-01T23:59:59.000Z

283

Technology Search Results | Brookhaven Technology ...  

There are no technology records available that match the search query. Find a Technology. Search our technologies by categories or by keywords.

284

Automatic tuning for linearly tunable filter  

E-Print Network (OSTI)

A new tuning scheme for linearly tunable high-Q filters is proposed. The tuning method is based on using the phase information for both frequency and Q factor tuning. There is no need to find out the relationship between a filter's passband magnitude and Q. A gm-C biquadratic filter is designed to demonstrate the proposed tuning circuitry. The project includes a phase locked loop (PLL) based frequency tuning loop, reference clock generator, and differential difference amplifier (DDA) for dealing with frequency and Q factor tuning loop and linearly tunable second order gm-C bandpass filter. Simulation results for a 10 MHz prototype filter using AMI 0.5?m process is presented. The chip testing results show that the automatic frequency tuning error is 2.5% for the 10 MHz case.

Huang, Sung-Ling

2003-05-01T23:59:59.000Z

285

Thermovoltaic semiconductor device including a plasma filter  

DOE Patents (OSTI)

A thermovoltaic energy conversion device and related method for converting thermal energy into an electrical potential. An interference filter is provided on a semiconductor thermovoltaic cell to pre-filter black body radiation. The semiconductor thermovoltaic cell includes a P/N junction supported on a substrate which converts incident thermal energy below the semiconductor junction band gap into electrical potential. The semiconductor substrate is doped to provide a plasma filter which reflects back energy having a wavelength which is above the band gap and which is ineffectively filtered by the interference filter, through the P/N junction to the source of radiation thereby avoiding parasitic absorption of the unusable portion of the thermal radiation energy.

Baldasaro, Paul F. (Clifton Park, NY)

1999-01-01T23:59:59.000Z

286

NUCLEAR RADIATION DOSIMETER USING COMPOSITE FILTER AND A SINGLE ELEMENT FILTER  

DOE Patents (OSTI)

A nuclear radiation dosimeter is described that uses, in combination, a composite filter and a single element filter. The composite filter contains a plurality of comminuted metals having K-edges evenly distributed over the energy range of interest and the quantity of each of the metals is selected to result in filtering in an amount inversely proportional to the sensitivity of the film in the range over l00 kev. A copper filter is used that has a thickness to contribute the necessary additional correction in the interval between 40 and 100 kev. (AEC)

Storm, E.; Shlaer, S.

1964-04-21T23:59:59.000Z

287

Dynamic interrelationship between technology and architecture in tall buildings  

E-Print Network (OSTI)

The interrelationship between the technology and architecture of tall buildings is investigated from the emergence of tall buildings in the late 19th century to the present. Through the historical research, a filtering ...

Moon, Kyoung-Sun

2005-01-01T23:59:59.000Z

288

OPTIMIZATION OF ADVANCED FILTER SYSTEMS  

NLE Websites -- All DOE Office Websites (Extended Search)

PROGRAM FINAL REPORT PROGRAM FINAL REPORT October 1, 1999 - August 30, 2001 By R. A. Newby (SWPC), Program Manager T. E. Lippert (SWPC) Rachid B. Slimane (GTI) O. Mehmet Akpolat (GTI) Keyur Pandya (GTI) Francis S. Lau (GTI) Javad Abbasian (GTI) Brett E. Williams (GTI) Dennis Leppin (GTI) August 2001 DOE Award Number: DE-AC26-99FT40674 Prepared for U.S. Department of Energy National Energy Technology Laboratory Prepared by Siemens Westinghouse Power Corporation Science & Technology Center 1310 Beulah Rd. Pittsburgh, Pennsylvania 15235 & Gas Technology Institute 1700 S. Mt. Prospect Rd. Des Plaines, Illinois 60018 i DISCLAIMER This report was prepared as an account of work sponsored by the United States Government. Neither the United States nor the United States Department of Energy, nor any of

289

Effects of diesel particle filter retrofits and accelerated fleet turnover  

NLE Websites -- All DOE Office Websites (Extended Search)

Effects of diesel particle filter retrofits and accelerated fleet turnover Effects of diesel particle filter retrofits and accelerated fleet turnover on drayage truck emissions at the port of Oakland Title Effects of diesel particle filter retrofits and accelerated fleet turnover on drayage truck emissions at the port of Oakland Publication Type Journal Article Year of Publication 2011 Authors Dallmann, Timothy R., Robert A. Harley, and Thomas W. Kirchstetter Journal Environmental Science & Technology Volume 45 Issue 24 Pagination 10773-10779 Abstract Heavy-duty diesel drayage trucks have a disproportionate impact on the air quality of communities surrounding major freight-handling facilities. In an attempt to mitigate this impact, the state of California has mandated new emission control requirements for drayage trucks accessing ports and rail yards in the state beginning in 2010. This control rule prompted an accelerated diesel particle filter (DPF) retrofit and truck replacement program at the Port of Oakland. The impact of this program was evaluated by measuring emission factor distributions for diesel trucks operating at the Port of Oakland prior to and following the implementation of the emission control rule. Emission factors for black carbon (BC) and oxides of nitrogen (NOx) were quantified in terms of grams of pollutant emitted per kilogram of fuel burned using a carbon balance method. Concentrations of these species along with carbon dioxide were measured in the exhaust plumes of individual diesel trucks as they drove by en route to the Port. A comparison of emissions measured before and after the implementation of the truck retrofit/replacement rule shows a 54 ± 11% reduction in the fleet-average BC emission factor, accompanied by a shift to a more highly skewed emission factor distribution. Although only particulate matter mass reductions were required in the first year of the program, a significant reduction in the fleet-average NOx emission factor (41 ± 5%) was observed, most likely due to the replacement of older trucks with new ones.

290

Microwave-Regenerated Diesel Exhaust Particulate Filter  

Science Conference Proceedings (OSTI)

Development of a microwave-regenerated particulate filter system has evolved from bench scale work to actual diesel engine experimentation. The filter system was initially evaluated on a stationary mounted 1.2-L diesel engine and was able to remove a significant amount of carbon particles from the exhaust. The ability of the microwave energy to regenerate or clean the filter was also demonstrated on this engine under idle conditions. Based on the 1.2-L experiments, improvements to the filter design and materials were implemented and the system was re-evaluated on a vehicle equipped with a 7.3-L diesel engine. The 7.3-L engine was selected to achieve heavy filter loading in a relatively short period of time. The purpose of these experiments was to evaluate filter-loading capacity, power requirements for regeneration, and filter regeneration efficiency. A more detailed evaluation of the filter was performed on a stationary mounted 1.9-L diesel engine. The effect of exhaust flow rate, loading, transients, and regeneration on filter efficiency was evaluated with this setup. In addition, gaseous exhaust emissions were investigated with and without an oxidation catalyst on the filter cartridge during loading and regeneration. (SAE Paper SAE-2001-01-0903 © 2001 SAE International. This paper is published on this website with permission from SAE International. As a user of this website, you are permitted to view this paper on-line, download this pdf file and print one copy of this paper at no cost for your use only. The downloaded pdf file and printout of this SAE paper may not be copied, distributed or forwarded to others or for the use of others.)

Nixdorf, Richard D. (Industrial Ceramic Solution, LLC); Green, Johney Boyd; Story, John M.; Wagner, Robert M. (Oak Ridge National Laboratory)

2001-03-05T23:59:59.000Z

291

Potential for Hepa filter damage from water spray systems in filter plenums  

SciTech Connect

The water spray systems in high efficiency particulate air (HEPA) filter plenums that are used in nearly all Department of Energy (DOE) facilities for protection against fire was designed under the assumption that the HEPA filters would not be damaged by the water sprays. The most likely scenario for filter damage involves filter plugging by the water spray, followed by the fan blowing out the filter medium. A number of controlled laboratory tests that were previously conducted in the late 1980s are reviewed in this paper to provide a technical basis for the potential HEPA filter damage by the water spray system in HEPA filter plenums. In addition to the laboratory tests, the scenario for HEPA filter damage during fires has also occurred in the field. Afire in a four-stage, HEPA filter plenum at Rocky Flats in 1980 caused the first three stages of HEPA filters to blow out of their housing and the fourth stage to severely bow. Details of this recently declassified fire are presented in this paper. Although these previous findings suggest serious potential problems exist with the current water spray system in filter plenum , additional studies are required to confirm unequivocally that DOE`s critical facilities are at risk.

Bergman, W.; Fretthold, J.K.; Slawsld, J.W.

1997-01-01T23:59:59.000Z

292

Automating data aggregation for collaborative filtering in Ruby on Rails  

E-Print Network (OSTI)

Collaborative filtering and information filtering are tried and proven methods of utilizing aggregated data about a website's users to provide catered content. Passive filters are one subset of such algorithms that utilize ...

Malconian, Daniel R

2008-01-01T23:59:59.000Z

293

Advanced Energy-Efficient Filtration: Fan Filter Unit  

E-Print Network (OSTI)

Efficient Fan- Filter Units, Proceedings of SEMI TechnicalFor Evaluating Fan-Filter Unit Performance – Applications inPerformance of Fan-Filter Units, Version 1.2 (2004, public

Xu, Tengfang

2005-01-01T23:59:59.000Z

294

Advanced Energy-Efficient Filtration: Fan Filter Unit  

E-Print Network (OSTI)

Cleanrooms: Energy Efficient Fan- Filter Units, ProceedingsStandard Method For Evaluating Fan-Filter Unit Performance –Energy Performance of Fan-Filter Units, Version 1.2 (2004,

Xu, Tengfang

2005-01-01T23:59:59.000Z

295

A Unification of Ensemble Square Root Kalman Filters  

Science Conference Proceedings (OSTI)

In recent years, several ensemble-based Kalman filter algorithms have been developed that have been classified as ensemble square root Kalman filters. Parallel to this development, the singular “evolutive” interpolated Kalman (SEIK) filter has ...

Lars Nerger; Tijana Janji?; Jens Schröter; Wolfgang Hiller

2012-07-01T23:59:59.000Z

296

The Dolph–Chebyshev Window: A Simple Optimal Filter  

Science Conference Proceedings (OSTI)

Analyzed data for numerical prediction can be effectively initialized by means of a digital filter. Computation time is reduced by using an optimal filter. The construction of optimal filters involves the solution of a nonlinear minimization ...

Peter Lynch

1997-04-01T23:59:59.000Z

297

Technology Search Results | Brookhaven Technology ...  

Staff Directory; BNL People Technology Commercialization & Partnerships. Home; For BNL Inventors; ... a nonprofit applied science and technology organization. ...

298

Technology Search Results | Brookhaven Technology ...  

Non-Noble Metal Water Electrolysis Catalysts; Find a Technology. Search our technologies by categories or by keywords. Search ...

299

Technology Search Results | Brookhaven Technology ...  

BSA 08-04: High Temperature Interfacial Superconductivity; Find a Technology. Search our technologies by categories or by keywords. Search ...

300

Technology Search Results | Brookhaven Technology ...  

Receive Technology Updates. Get email notifications about new or improved technologies in your area of interest. Subscribe »

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

TESTING OF THE DUAL ROTARY FILTER SYSTEM  

SciTech Connect

The Savannah River National Laboratory (SRNL) installed and tested two hydraulically connected SpinTek rotary microfilter (RMF) units to determine the behavior of a multiple filter system. Both units were successfully controlled by a control scheme written in DELTA-V architecture by Savannah River Remediation (SRR) Process Control Engineering personnel. The control system was tuned to provide satisfactory response to changing conditions during the operation of the multi-filter system. Stability was maintained through the startup and shutdown of one of the filter units while the second was still in operation. The installation configuration originally proposed by the Small Colum Ion Exchange (SCIX) project of independent filter and motor mountings may be susceptible to vibration. Significant stiffening of the filter and motor mounts was required to minimize the vibration. Alignment of the motor to the filter was a challenge in this test configuration. The deployment configuration must be easy to manipulate and allow for fine adjustment. An analysis of the vibration signature of the test system identified critical speeds. Whether it corresponds to the resonance frequency of a rotor radial vibration mode that was excited by rotor unbalance is uncertain based upon the measurements. A relative motion series should be completed on the filter with the final shaft configuration to determine if the resonances exist in the final filter design. The instrumentation selected for deployment, including the concentrate discharge control valve and flow meters, performed well. Automation of the valve control integrated well with the control scheme and when used in concert with the other control variables, allowed automated control of the dual RMF system. The one area of concern with the instrumentation was the condition resulting when the filtrate flow meter operated with less than three gpm. This low flow was at the lower range of performance for the flow meter. This should not be an issue in deployment where the desired flow rate will be within the normal operating range of the meter. Testing demonstrated that the use of a flexible line for the filtrate discharge is highly desired at the outlet of the rotary union to transition to the system piping. Isolating the vibration from the rotary union will significantly improve the lifetime of the seals. Methods to monitor and isolate individual filters should be considered during deployment. The ability to diagnose issues and isolate individual filters would allow isolation prior to failure. Thus, filters may be cleaned or repaired instead of requiring complete replacement if the condition were to continue unnoticed. Isolating the filtrate line of each filter during startup will minimize the premature buildup of solids on the filter disks. Several tests have shown that the method of filter startup can improve performance lifetime of the filters. The installation must factor in an air inlet for the draining of a filter that does not involve a reverse flow through the filter disks. The reverse flow may cause deformation of the disks or may damage other components of the filters themselves.

Herman, D.; Fowley, M.; Stefanko, D.

2011-08-29T23:59:59.000Z

302

Multiple stage multiple filter hydrate store  

DOE Patents (OSTI)

An improved hydrate store for a metal halogen battery system is disclosed which employs a multiple stage, multiple filter means for separating the halogen hydrate from the liquid used in forming the hydrate. The filter means is constructed in the form of three separate sections which combine to substantially cover the interior surface of the store container. Exit conduit means is provided in association with the filter means for transmitting liquid passing through the filter means to a hydrate former subsystem. The hydrate former subsystem combines the halogen gas generated during the charging of the battery system with the liquid to form the hydrate in association with the store. Relief valve means is interposed in the exit conduit means for controlling the operation of the separate sections of the filter means, such that the liquid flow through the exit conduit means from each of the separate sections is controlled in a predetermined sequence. The three separate sections of the filter means operate in three discrete stages to provide a substantially uniform liquid flow to the hydrate former subsystem during the charging of the battery system. The separation of the liquid from the hydrate causes an increase in the density of the hydrate by concentrating the hydrate along the filter means. 7 figs.

Bjorkman, H.K. Jr.

1983-05-31T23:59:59.000Z

303

Moving Granular Bed Filter Development Program  

SciTech Connect

The granular bed filter was developed through low pressure, high temperature (1600{degrees}F) testing in the late 1970`s and early 1980`s`. Collection efficiencies over 99% were obtained. In 1988, high pressure, high temperature testing was completed at New York University, Westbury, N.Y., utilizing a coal-fired pressurized, fluidized bed combustor. High particulate removal efficiencies were confirmed as it was shown that both New Source Performance Standards and turbine tolerance limits could be met. The early scale-up work of the granular bed filter indicated potential limitations due to size, cost, and mechanical complexity. These limitations were addressed in the present program by utilizing the information gained from the filter development up through the NYU test program to reassess the commercial approach. Two studies were chosen for developing conceptual designs and cost estimates of the commercial sized filters. One is the economic study of the 250 MWe, second generation pressurized fluidized bed combustion plant defined by Foster Wheeler. This plant originally included cross-flow filters for hot gas cleanup. The other plant under study is a 100 MWe, airblown KRW gasifier. A cross-flow inter was utilized for gas stream cleanup in this study also. Granular bed and ceramic candle filters were substituted for the cross-flow filters in both these plants, and the resulting cost of electricity (COE) is compared.

Wilson, K.B.; Haas, J.C.; Eshelman, M.B.

1992-11-01T23:59:59.000Z

304

Moving Granular Bed Filter Development Program  

SciTech Connect

The granular bed filter was developed through low pressure, high temperature (1600[degrees]F) testing in the late 1970's and early 1980's'. Collection efficiencies over 99% were obtained. In 1988, high pressure, high temperature testing was completed at New York University, Westbury, N.Y., utilizing a coal-fired pressurized, fluidized bed combustor. High particulate removal efficiencies were confirmed as it was shown that both New Source Performance Standards and turbine tolerance limits could be met. The early scale-up work of the granular bed filter indicated potential limitations due to size, cost, and mechanical complexity. These limitations were addressed in the present program by utilizing the information gained from the filter development up through the NYU test program to reassess the commercial approach. Two studies were chosen for developing conceptual designs and cost estimates of the commercial sized filters. One is the economic study of the 250 MWe, second generation pressurized fluidized bed combustion plant defined by Foster Wheeler. This plant originally included cross-flow filters for hot gas cleanup. The other plant under study is a 100 MWe, airblown KRW gasifier. A cross-flow inter was utilized for gas stream cleanup in this study also. Granular bed and ceramic candle filters were substituted for the cross-flow filters in both these plants, and the resulting cost of electricity (COE) is compared.

Wilson, K.B.; Haas, J.C.; Eshelman, M.B.

1992-01-01T23:59:59.000Z

305

Technology Transfer: Available Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

Please refer to the list of technologies below for licensing and research Please refer to the list of technologies below for licensing and research collaboration availability. If you can't find the technology you're interested in, please contact us at TTD@lbl.gov. Biotechnology and Medicine DIAGNOSTICS AND THERAPEUTICS CANCER CANCER PROGNOSTICS 14-3-3 Sigma as a Biomarker of Basal Breast Cancer ANXA9: A Therapeutic Target and Predictive Marker for Early Detection of Aggressive Breast Cancer Biomarkers for Predicting Breast Cancer Patient Response to PARP Inhibitors Breast Cancer Recurrence Risk Analysis Using Selected Gene Expression Comprehensive Prognostic Markers and Therapeutic Targets for Drug-Resistant Breast Cancers Diagnostic Test to Personalize Therapy Using Platinum-based Anticancer Drugs Early Detection of Metastatic Cancer Progenitor Cells

306

Performance evaluation of diesel particulate filters on heavy duty vehicles.  

E-Print Network (OSTI)

??Diesel particulate filters, or DPFs, are exhaust aftertreatment devices used to reduce exhaust emissions from diesel powered vehicles. Typical designs have a wall flow filter… (more)

Rosepiler, Stephen G.

2003-01-01T23:59:59.000Z

307

U-252: Barracuda Web Filter Input Validation Flaws Permit Cross...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

2: Barracuda Web Filter Input Validation Flaws Permit Cross-Site Scripting Attacks U-252: Barracuda Web Filter Input Validation Flaws Permit Cross-Site Scripting Attacks September...

308

The Investigation of Minor Element Additions on Oxide Filtering and ...  

Science Conference Proceedings (OSTI)

USA. Summary. Effects of minor element additions on filtering were studied ... demand. An understanding of the phenomena involved in the filtering process.

309

Filter:Incentives by Efficiency or Renewable | Open Energy Information  

Open Energy Info (EERE)

Efficiency or Renewable Jump to: navigation, search This filter covers the property IncentiveEnergyCat. Retrieved from "http:en.openei.orgwindex.php?titleFilter:Incentivesby...

310

Technology Transfer: Available Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

Software and Information Technologies Software and Information Technologies Algorithm for Correcting Detector Nonlinearites Chatelet: More Accurate Modeling for Oil, Gas or Geothermal Well Production Collective Memory Transfers for Multi-Core Processors Energy Efficiency Software EnergyPlus:Energy Simulation Software for Buildings Tools, Guides and Software to Support the Design and Operation of Energy Efficient Buildings Flexible Bandwidth Reservations for Data Transfer Genomic and Proteomic Software LABELIT - Software for Macromolecular Diffraction Data Processing PHENIX - Software for Computational Crystallography Vista/AVID: Visualization and Allignment Software for Comparative Genomics Geophysical Software Accurate Identification, Imaging, and Monitoring of Fluid Saturated Underground Reservoirs

311

Frequency Selective Surfaces as Near Infrared Electro-Magnetic Filters for Thermophotovoltaic Spectral Control  

DOE Green Energy (OSTI)

Frequency selective surfaces (FSS) effectively filter electromagnetic radiation in the microwave band (1mm to 100mm). Interest exists in extending this technology to the near infrared (1 {micro}m to 10 {micro}m) for use as a filter of thermal radiation in thermophotovoltaic (TPV) direct energy conversion. This paper assesses the ability of FSS to meet the strict spectral performance requirements of a TPV system. Inherent parasitic absorption, which is the result of the induced currents in the FSS metallization, is identified as a significant obstacle to achieving high spectral performance.

Ryan T. Kristensen; John F. Beausang; David M. DePoy

2003-12-01T23:59:59.000Z

312

Frequency Selective Surfaces as Near Infrared Electro-Magnetic Filters for Thermophotovoltaic Spectral Control  

DOE Green Energy (OSTI)

Frequency selective surfaces (FSS) effectively filter electromagnetic radiation in the microwave band (1 mm to 100 mm). Interest exists in extending this technology to the near infrared (1 {micro}m to 10 {micro}m) for use as a filter of thermal radiation in thermophotovoltaic (TPV) direct energy conversion. This paper assesses the ability of FSS to meet the strict spectral performance requirements of a TPV system. Inherent parasitic absorption, which is the result of the induced currents in the FSS metallization, is identified as a significant obstacle to achieving high spectral performance.

RF Kristensen; JF Beausang; DM DePoy

2004-06-28T23:59:59.000Z

313

Navy Technology Validation (Techval)  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Technology Technology Validation (Techval) FUPWG Spring Meeting 2008 April 15, 2008 Destin, FL Paul Kistler, PE CEM NAVFAC Engineering Service Center Port Hueneme CA Navy Techval CURRENT PROJECTS * Cool Roof reflective roof coating  NS Pearl Harbor HI * Thermal Destratifiers  NAS Oceana VA * Boiler Combustion Controls  USNA Annapolis MD * Sand Filters  NAS Lemoore CA * Spectrally Enhanced Lighting  Navy Yard Washington DC * Desuperheater  NS Norfolk VA  NAS North Island CA * HVAC CO2 Controls  NAB Little Creek VA  NAVSUPPACT Mid-South TN  NB Kitsap Bremerton WA *HVAC Occupancy Controls NAS Oceana VA *Electromagnetic Pulse Water Treatment NADEP San Diego CA NSY Puget Sound WA *LED Parking Lot Lighting NBVC Port Hueneme CA Techval

314

Optimal Filtering of AC Output Anemometers  

Science Conference Proceedings (OSTI)

The output of pulsed and AC output anemometers suffer from discretization noise when such anemometers are sampled at fast rates (>1 Hz). This paper describes the construction of an optimal filter designed to reduce this noise. By comparing the ...

J. C. Barnard; L. L. Wendell; V. R. Morris

1998-12-01T23:59:59.000Z

315

A filter model for mobile processes  

Science Conference Proceedings (OSTI)

This paper presents a filter model for ?-calculus and shows its full abstraction with respect to a ‘may’ operational semantics. The model is introduced in the form of a type assignment system. Types are related by a preorder that mimics ...

Ferruccio Damiani; Mariangiola Dezani-Ciancaglini; Paola Giannini

1999-02-01T23:59:59.000Z

316

Electro-optical tunable birefringent filter  

DOE Patents (OSTI)

An electrically tunable Lyot type filter is a Lyot that include one or more filter elements. Each filter element may have a planar, solid crystal comprised of a material that exhibits birefringence and is electro-optically active. Transparent electrodes may be coated on each face of the crystal. An input linear light polarizer may be located on one side of the crystal and oriented at 45 degrees to the optical axis of the birefringent crystal. An output linear light polarizer may be located on the other side of the crystal and oriented at -45 degrees with respect to the optical axis of the birefringent crystal. When an electric voltage is applied between the electrodes, the retardation of the crystal changes and so does the spectral transmission of the optical filter.

Levinton, Fred M. (Princeton, NJ)

2012-01-31T23:59:59.000Z

317

Advanced filters and components for power applications  

E-Print Network (OSTI)

The objective of this thesis is to improve the high frequency performance of components and filters by better compensating the parasitic effects of practical components. The main application for this improvement is in ...

Neugebauer, Timothy Carl, 1975-

2004-01-01T23:59:59.000Z

318

Filtering Turbulent Sparsely Observed Geophysical Flows  

Science Conference Proceedings (OSTI)

Filtering sparsely turbulent signals from nature is a central problem of contemporary data assimilation. Here, sparsely observed turbulent signals from nature are generated by solutions of two-layer quasigeostrophic models with turbulent cascades ...

John Harlim; Andrew J. Majda

2010-04-01T23:59:59.000Z

319

Maximum Likelihood Ensemble Filter: Theoretical Aspects  

Science Conference Proceedings (OSTI)

A new ensemble-based data assimilation method, named the maximum likelihood ensemble filter (MLEF), is presented. The analysis solution maximizes the likelihood of the posterior probability distribution, obtained by minimization of a cost ...

Milija Zupanski

2005-06-01T23:59:59.000Z

320

Dissipative Cryogenic Filters with Zero DC Resistance  

SciTech Connect

The authors designed, implemented and tested cryogenic RF filters with zero DC resistance, based on wires with a superconducting core inside a resistive sheath. The superconducting core allows low frequency currents to pass with negligible dissipation. Signals above the cutoff frequency are dissipated in the resistive part due to their small skin depth. The filters consist of twisted wire pairs shielded with copper tape. Above approximately 1 GHz, the attenuation is exponential in {radical}{omega}, as typical for skin depth based RF filters. By using additional capacitors of 10 nF per line, an attenuation of at least 45 dB above 10 MHz can be obtained. Thus, one single filter stage kept at mixing chamber temperature in a dilution refrigerator is sufficient to attenuate room temperature black body radiation to levels corresponding to 10 mK above about 10 MHz.

Bluhm, Hendrik; Moler, Kathryn A.; /Stanford U., Appl. Phys. Dept

2008-04-22T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

GLOBAL CONVERGENCE OF SLANTING FILTER METHODS FOR ...  

E-Print Network (OSTI)

After the iteration is completed, this entry will become permanent in the filter only if the iteration doe¤ not produce a decrease in fo. In particular, note that if h(x() ...

322

Plasma Mass Filters For Nuclear Waste Reprocessing  

SciTech Connect

Practical disposal of nuclear waste requires high-throughput separation techniques. The most dangerous part of nuclear waste is the fission product, which contains the most active and mobile radioisotopes and produces most of the heat. We suggest that the fission products could be separated as a group from nuclear waste using plasma mass filters. Plasmabased processes are well suited to separating nuclear waste, because mass rather than chemical properties are used for separation. A single plasma stage can replace several stages of chemical separation, producing separate streams of bulk elements, fission products, and actinoids. The plasma mass filters may have lower cost and produce less auxiliary waste than chemical processing plants. Three rotating plasma configurations are considered that act as mass filters: the plasma centrifuge, the Ohkawa filter, and the asymmetric centrifugal trap.

Abraham J. Fetterman and Nathaniel J. Fisch

2011-05-26T23:59:59.000Z

323

Analysis Scheme in the Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

This paper discusses an important issue related to the implementation and interpretation of the analysis scheme in the ensemble Kalman filter. It is shown that the observations must be treated as random variables at the analysis steps. That is, ...

Gerrit Burgers; Peter Jan van Leeuwen; Geir Evensen

1998-06-01T23:59:59.000Z

324

Mayday: distributed filtering for internet services  

Science Conference Proceedings (OSTI)

Mayday is an architecture that combines overlay networks with lightweight packet filtering to defend against denial of service attacks. The overlay nodes perform client authentication and protocol verification, and then relay the requests to a protected ...

David G. Andersen

2003-03-01T23:59:59.000Z

325

Electrical diesel particulate filter (DPF) regeneration  

SciTech Connect

An exhaust system that processes exhaust generated by an engine includes a diesel particulate filter (DPF) that is disposed downstream of the engine and that filters particulates from the exhaust. An electrical heater is disposed upstream of the DPF and selectively heats the exhaust to initiate combustion of the particulates within the exhaust as it passes therethrough. Heat generated by combustion of the particulates induces combustion of particulates within the DPF.

Gonze, Eugene V; Ament, Frank

2013-12-31T23:59:59.000Z

326

Active imaging system with Faraday filter  

DOE Patents (OSTI)

This invention is comprised of an active imaging system which has a low to medium powered laser transmitter and a receiver wherein the receiver includes a Faraday filter with an ultranarrow optical bandpass and a bare (nonintensified) CCD camera. The laser is locked in the vicinity of the passband of the Faraday filter. The system has high sensitivity to the laser illumination wile eliminating solar background.

Snyder, J.J.

1992-12-31T23:59:59.000Z

327

Pulse-Jet Fabric Filter Guidelines  

Science Conference Proceedings (OSTI)

Power plants need to reduce stack emissions of mercury, filterable particulate matter (FPM),  and acid gases to comply with the Mercury and Air Toxics Standards (MATS) issued by the U.S. Environmental Protection Agency (EPA) on February 16, 2012. The MATS standard requires that total stack FPM be maintained at < 0.03 lb/MMBtu. As particulate emission regulations become more stringent, the use of baghouses (also known as fabric filters) for particulate control on coal-fired boilers in the ...

2012-12-13T23:59:59.000Z

328

Technology Transfer: Available Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

Ion Sources and Beam Technologies Ion Sources and Beam Technologies GENERATORS AND DETECTORS Compact, Safe and Energy Efficient Neutron Generator Fast Pulsed Neutron Generator High Energy Gamma Generator Lithium-Drifted Silicon Detector with Segmented Contacts Low Power, High Energy Gamma Ray Detector Calibration Device Nested Type Coaxial Neutron Generator Neutron and Proton Generators: Cylindrical Neutron Generator with Nested Option, IB-1764 Neutron-based System for Nondestructive Imaging, IB-1794 Mini Neutron Tube, IB-1793a Ultra-short Ion and Neutron Pulse Production, IB-1707 Mini Neutron Generator, IB-1793b Compact Spherical Neutron Generator, IB-1675 Plasma-Driven Neutron/Gamma Generators Portable, Low-cost Gamma Source for Active Interrogation ION SOURCES WITH ANTENNAS External Antenna for Ion Sources

329

A Fast Network Flow Model is used in conjunction with Measurements of Filter Permeability to calculate the Performance of Hot Gas Filters  

SciTech Connect

Two different technologies that are being considered for generating electric power on a large scale by burning coal are Pressurized Fluid Bed Combustion (PFBC) systems and Integrated Gasification and Combined Cycle (IGCC) systems. Particulate emission regulations that have been proposed for future systems may require that these systems be fitted with large scale Hot Gas Clean-Up (HGCU) filtration systems that would remove the fine particulate matter from the hot gas streams that are generated by PFBC and IGCC systems. These hot gas filtration systems are geometrically and aerodynamically complex. They typically are constructed with large arrays of ceramic candle filter elements (CFE). The successful design of these systems require an accurate assessment of the rate at which mechanical energy of the gas flow is dissipated as it passes through the filter containment vessel and the individual candle filter elements that make up the system. Because the filtration medium is typically made of a porous ceramic material having open pore sizes that are much smaller than the dimensions of the containment vessel, the filtration medium is usually considered to be a permeable medium that follows Darcy's law. The permeability constant that is measured in the lab is considered to be a function of the filtration medium only and is usually assumed to apply equally to all the filters in the vessel as if the flow were divided evenly among all the filter elements. In general, the flow of gas through each individual CFE will depend not only on the geometrical characteristics of the filtration medium, but also on the local mean flows in the filter containment vessel that a particular filter element sees. The flow inside the CFE core, through the system manifolds, and inside the containment vessel itself will be coupled to the flow in the filter medium by various Reynolds number effects. For any given filter containment vessel, since the mean flows are different in different locations inside the vessel, the flow of gas through an individual CFE will adjust itself to accommodate the local mean flows that prevail in its general location. In some locations this adjustment will take place at High Reynolds numbers and in other locations this will occur at low Reynolds numbers. The analysis done here investigates the nature of this coupling.

VanOsdol, J.G.; Chiang, T-K.

2002-09-19T23:59:59.000Z

330

Tools & Technologies  

Energy.gov (U.S. Department of Energy (DOE))

We provide leadership for transforming workforce development through the power of technology. It develops corporate educational technology policy and enables the use of learning tools and...

331

Available Technologies  

The technology’s subnanometer resolution is a result of superior ... Additional R&D will be required ... U.S. DEPARTMENT OF ENERGY • OFFICE OF SCIENCE ...

332

CFD Analysis of Core Bypass Flow and Crossflow in the Prismatic Very High Temperature Gas-cooled Nuclear Reactor  

E-Print Network (OSTI)

Very High Temperature Rector (VHTR) had been designated as one of those promising reactors for the Next Generation (IV) Nuclear Plant (NGNP). For a prismatic core VHTR, one of the most crucial design considerations is the bypass flow and crossflow effect. The bypass flow occurs when the coolant flow into gaps between fuel blocks. These gaps are formed as a result of carbon expansion and shrinkage induced by radiations and manufacturing and installation errors. Hot spots may appear in the core if the large portion of the coolant flows into bypass gaps instead of coolant channels in which the cooling efficiency is much higher. A preliminary three dimensional steady-state CFD analysis was performed with commercial code STARCCM+ 6.04 to investigate the bypass flow and crossflow phenomenon in the prismatic VHTR core. The k-? turbulence model was selected because of its robustness and low computational cost with respect to a decent accuracy for varied flow patterns. The wall treatment used in the present work is two-layer all y+ wall treatment to blend the wall laws to estimate the shear stress. Uniform mass flow rate was chose as the inlet condition and the outlet condition was zero gauge pressure outlet. Grid independence study was performed and the results indicated that the discrepancy of the solution due to the mesh density was within 2% of the bypass flow fraction. The computational results showed that the bypass flow fraction was around 12%. Furthermore, the presence of the crossflow gap resulted in a up to 28% reduction of the coolant in the bypass flow gap while mass flow rate of coolant in coolant channels increased by around 5%. The pressure drop at the inlet due to the sudden contraction in area could be around 1kpa while the value was about 180 Pa around the crossflow gap region. The error analysis was also performed to evaluate the accumulated errors from the process of discretization and iteration. It was found that the total error was around 4% and the variation for the bypass flow fraction was within 1%.

Wang, Huhu 1985-

2012-12-01T23:59:59.000Z

333

Vehicle Technologies Office: Fact #568: April 27, 2009 For Modern Cars,  

NLE Websites -- All DOE Office Websites (Extended Search)

8: April 27, 8: April 27, 2009 For Modern Cars, Replacing an Air Filter Will Improve Performance but Not Fuel Economy to someone by E-mail Share Vehicle Technologies Office: Fact #568: April 27, 2009 For Modern Cars, Replacing an Air Filter Will Improve Performance but Not Fuel Economy on Facebook Tweet about Vehicle Technologies Office: Fact #568: April 27, 2009 For Modern Cars, Replacing an Air Filter Will Improve Performance but Not Fuel Economy on Twitter Bookmark Vehicle Technologies Office: Fact #568: April 27, 2009 For Modern Cars, Replacing an Air Filter Will Improve Performance but Not Fuel Economy on Google Bookmark Vehicle Technologies Office: Fact #568: April 27, 2009 For Modern Cars, Replacing an Air Filter Will Improve Performance but Not Fuel Economy on Delicious

334

Proceedings: Indoor Air 2005 OZONE REMOVAL BY RESIDENTIAL HVAC FILTERS  

E-Print Network (OSTI)

Proceedings: Indoor Air 2005 2366 OZONE REMOVAL BY RESIDENTIAL HVAC FILTERS P Zhao1,2 , JA Siegel1, Austin, Texas 78758, USA ABSTRACT HVAC filters have a significant influence on indoor air quality% for Filter #2 at a face velocity of 0.81 cm/s. The potential for HVAC filters to affect ozone concentrations

Siegel, Jeffrey

335

A noise rejection deadbeat control technique for active power filter  

Science Conference Proceedings (OSTI)

Compared with power filter, active power filter has a lot of advantages and it is an efficient technique to eliminate or limit the harmonic pollution in power system. However, the control of active power filter is very complex, and the control of current ... Keywords: active power filter, current control technique, deadbeat control, noise rejection, periodic noise, resetting integrator, sampling noise

Li-Dan Zhou; Mansoor Mansoor; Qian Ai; Da Xie; Chen Chen

2005-10-01T23:59:59.000Z

336

Electrically heated particulate matter filter with recessed inlet end plugs  

DOE Patents (OSTI)

A particulate matter (PM) filter includes filter walls having inlet ends and outlet ends. First adjacent pairs of the filter walls define inlet channels. Second adjacent pairs of the filter walls define outlet channels. Outlet end plugs are arranged in the inlet channels adjacent to the output ends. Inlet end plugs arranged in the outlet channels spaced from the inlet ends.

Gonze, Eugene V. (Pinckney, MI); Ament, Frank (Troy, MI)

2012-02-21T23:59:59.000Z

337

The State of the Art in Text Filtering  

Science Conference Proceedings (OSTI)

This paper develops a conceptual framework for text filtering practice and research, and reviews present practice in the field. Text filtering is an information seeking process in which documents are selected from a dynamic text stream to satisfy ... Keywords: Selective Dissemination of Information, collaborative, content-based, current awareness, information filtering, recommender systems., social filtering, text retrieval

Douglas W. Oard

1997-03-01T23:59:59.000Z

338

Restoration of audio documents by means of extended Kalman filter  

Science Conference Proceedings (OSTI)

We present some results on audio restoration obtained with an algorithm that solves the problems of broadband noise filtering, signal parameters tracking, and impulsive noise removal by using the Extended Kalman Filter (EKF) theory. We show that, to ... Keywords: Kalman filtering, audio restoration, audio signal processing, extended Kalman filter (EKF), identification of time-varying autoregressive processes

Sergio Canazza; Giovanni De Poli; Gian Antonio Mian

2010-08-01T23:59:59.000Z

339

Electrical and thermal finite element modeling of arc faults in photovoltaic bypass diodes.  

DOE Green Energy (OSTI)

Arc faults in photovoltaic (PV) modules have caused multiple rooftop fires. The arc generates a high-temperature plasma that ignites surrounding materials and subsequently spreads the fire to the building structure. While there are many possible locations in PV systems and PV modules where arcs could initiate, bypass diodes have been suspected of triggering arc faults in some modules. In order to understand the electrical and thermal phenomena associated with these events, a finite element model of a busbar and diode was created. Thermoelectrical simulations found Joule and internal diode heating from normal operation would not normally cause bypass diode or solder failures. However, if corrosion increased the contact resistance in the solder connection between the busbar and the diode leads, enough voltage potentially would be established to arc across micron-scale electrode gaps. Lastly, an analytical arc radiation model based on observed data was employed to predicted polymer ignition times. The model predicted polymer materials in the adjacent area of the diode and junction box ignite in less than 0.1 seconds.

Bower, Ward Isaac; Quintana, Michael A.; Johnson, Jay

2012-01-01T23:59:59.000Z

340

Open cycle ocean thermal energy conversion steam control and bypass system  

DOE Patents (OSTI)

Two sets of hinged control doors for regulating motive steam flow from an evaporator to a condenser alternatively through a set of turbine blades in a steam bypass around the turbine blades. The evaporator has a toroidal shaped casing situated about the turbine's vertical axis of rotation and an outlet opening therein for discharging motive steam into an annular steam flow path defined between the turbine's radially inner and outer casing structures. The turbine blades extend across the steam flow path intermediate the evaporator and condenser. The first set of control doors is arranged to prevent steam access to the upstream side of the turbine blades and the second set of control doors acts as a bypass around the blades so as to maintain equilibrium between the evaporator and condenser during non-rotation of the turbine. The first set of control doors preferably extend, when closed, between the evaporator casing and the turbine's outer casing and, when open, extend away from the axis of rotation. The second set of control doors preferably constitute a portion of the turbine's outer casing downstream from the blades when closed and extend, when open, toward the axis of rotation. The first and second sets of control doors are normally held in the open and closed positions respectively by locking pins which may be retracted upon detecting an abnormal operating condition respectively to permit their closing and opening and provide steam flow from the evaporator to the condenser.

Wittig, J. Michael (West Goshen, PA); Jennings, Stephen J. (Radnor Township, Delaware County, PA)

1980-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Post-Combustion CO2 Capture Technology Development  

Science Conference Proceedings (OSTI)

This report provides an update on the development trends in post-combustion carbon dioxide (CO2) capture technologies. The Electric Power Research Institute (EPRI) scouted carbon capture technologies worldwide and applied filtering criteria to identify those best suited for EPRI support. Those criteria included a technology developer's interest in working with EPRI, the potential for EPRI investment to provide significant advancement, the technology's suitability for broad application, and its potential ...

2010-12-31T23:59:59.000Z

342

Vehicle Technologies Office: Vehicle Technologies Office Organization...  

NLE Websites -- All DOE Office Websites (Extended Search)

Organization and Contacts Organization Chart for the Vehicle Technologies Program Fuel Technologies and Deployment, Technology Managers Advanced Combustion Engines, Technology...

343

Fuel Cell Technologies Office: Technology Validation  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Information Technology Validation Search Search Help Technology Validation EERE Fuel Cell Technologies Office Technology Validation Printable Version Share this resource...

344

Method of and apparatus for testing the integrity of filters  

DOE Patents (OSTI)

A method of and apparatus are disclosed for testing the integrity of individual filters or filter stages of a multistage filtering system including a diffuser permanently mounted upstream and/or downstream of the filter stage to be tested for generating pressure differentials to create sufficient turbulence for uniformly dispersing trace agent particles within the airstream upstream and downstream of such filter stage. Samples of the particle concentration are taken upstream and downstream of the filter stage for comparison to determine the extent of particle leakage past the filter stage. 5 figs.

Herman, R.L.

1985-05-07T23:59:59.000Z

345

Method of and apparatus for testing the integrity of filters  

DOE Patents (OSTI)

A method of and apparatus for testing the integrity of individual filters or filter stages of a multistage filtering system including a diffuser permanently mounted upstream and/or downstream of the filter stage to be tested for generating pressure differentials to create sufficient turbulence for uniformly dispersing trace agent particles within the airstream upstream and downstream of such filter stage. Samples of the particle concentration are taken upstream and downstream of the filter stage for comparison to determine the extent of particle leakage past the filter stage.

Herman, Raymond L. (Richland, WA)

1985-01-01T23:59:59.000Z

346

Methods of and apparatus for testing the integrity of filters  

DOE Patents (OSTI)

A method of and apparatus for testing the integrity of individual filters or filter stages of a multistage filtering system including a diffuser permanently mounted upstream and/or downstream of the filter stage to be tested for generating pressure differentials to create sufficient turbulence for uniformly dispersing trace agent particles within the airstram upstream and downstream of such filter stage. Samples of the particel concentration are taken upstream and downstream of the filter stage for comparison to determine the extent of particle leakage past the filter stage.

Herman, R.L.

1984-01-01T23:59:59.000Z

347

Physical gas stream cleanup: Technology status report  

SciTech Connect

This report is a summary of the status of particulate control technologies for use at high temperatures and high pressures. The technologies are being developed under the Physical Gas Stream Cleanup Program that is administered by the US Department of Energy, Morgantown Energy Technology Center. The intended uses of the particulate control technologies are to protect components in advanced coal systems, such as integrated gasification combined cycles, pressurized fluidized-bed combustion combined cycles, gasification molten carbonate fuel cells, and direct coal-fueled turbines. The use of particulate control technologies for these advanced energy conversion systems requires separation and collection of particles at temperatures in excess of 1000/sup 0/F and at pressures in excess of 7 atmospheres. These temperature and pressure regimes represent a drastic departure from those of conventional technologies. The Physical Gas Stream Cleanup Program seeks to establish a technical and economic data base that will demonstrate the feasibility of high-temperature, high-pressure particulate control. Particulate control concepts and their corresponding research and development projects are described in this report. These projects include subpilot-scale tests of an electrostatic precipitator, a ceramic cross-flow filter, and a screenless granular-bed filter on a 30-inch diameter pressurized fluidized-bed combustor. Bench-scale tests will also be conducted using a ceramic cross-flow filter, a ceramic bag filter, and an electrostatic precipitator on a 6-inch diameter fluidized-bed gasifier. Additional research involves laboratory evaluation of acoustic agglomeration, turbulence characterization and suppression in cyclones and characterization of ceramic fabrics for bag filters. Each project and significant accomplishments in FY 85 are described. 14 refs., 25 figs., 5 tabs.

1986-04-01T23:59:59.000Z

348

A Simple Candle Filter Safeguard Device  

SciTech Connect

In order to reach the highest possible efficiencies in a coal-fired turbine-based power system, the turbine should be directly fired with the products of coal utilization. Two main designs employ these turbines: those based on pressurized fluidized-bed combustors (PFBCs) and those based on integrated gasification combined cycles (IGCCs). In both designs, the suspended particulates, or dust, must be cleaned from the gas before it enters the turbine to prevent fouling and erosion of the blades. To produce the cleanest gas, barrier filters are being developed and are in commercial use. Barrier filters are composed of porous, high-temperature materials that allow the hot gas to pass but collect the dust on the surface. The three main configurations are candle, cross-flow, and tube. Both candle and tube filters have been tested extensively. They are primarily composed of coarsely porous ceramic that serves as a structural support, overlain with a thin, microporous ceramic layer o n the dirty gas side that serves as the primary filter surface. They are highly efficient at removing particulate matter from the gas stream and, because of their ceramic construction, are resistant to gas and ash corrosion. However, ceramics are brittle, and individual elements can fail, allowing the particulates to pass through the hole left by the filter element and erode the turbine. Because of the possibility of occasional filter breakage, safeguard devices (SGDs) must be employed to prevent the dust streaming through broken filters from reaching the turbine. The Energy & Environmental Research Center (EERC) safeguard device is composed of three main parts: the ceramic substrate, the adhesive coating, and the safeguard device housing. This report describes the development and laboratory testing of each of those parts as well as the bench-scale performance of both types of complete SGDs.

Hurley, J.P.; Henderson, A.K.; Swanson, M.L.

2002-09-18T23:59:59.000Z

349

Chemistry - Technology Transfer: Available Technologies  

Please refer to the list of technologies below for licensing and research collaboration availability. If you can't find the technology you ...

350

Technology Analysis - Heavy Vehicle Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

the GPRA benefits estimates for EERE's Vehicle Technologies Program's heavy vehicle technology research activities. Argonne researchers develop the benefits analysis using four...

351

Available Technologies  

APPLICATIONS OF TECHNOLOGY: Thermal management for: microelectronic devices; solar cells and solar energy management systems ; refrigerators

352

Available Technologies  

Energy Storage and Recovery; Renewable Energy; Environmental Technologies. Monitoring and Imaging; Remediation; Modeling; Imaging & Lasers.

353

Carbon fiber composite molecular sieve electrically regenerable air filter media  

DOE Patents (OSTI)

An electrically regenerable gas filter system includes a carbon fiber composite molecular sieve (CFCMS) filter medium. After a separate medium-efficiency pre-filter removes particulate from the supply airstream, the CFCMS filter sorbs gaseous air pollutants before the air is recirculated to the space. When saturated, the CFCMS media is regenerated utilizing a low-voltage current that is caused to pass through the filter medium.

Wilson, Kirk A. (Knoxville, TN); Burchell, Timothy D. (Oak Ridge, TN); Judkins, Roddie R. (Knoxville, TN)

1998-01-01T23:59:59.000Z

354

Hydrocarbon-enhanced particulate filter regeneration via microwave ignition  

DOE Patents (OSTI)

A regeneration method for a particulate filter includes estimating a quantity of particulate matter trapped within the particulate filter, comparing the quantity of particulate matter to a predetermined quantity, heating at least a portion of the particulate filter to a combustion temperature of the particulate matter, and introducing hydrocarbon fuel to the particulate filter. The hydrocarbon fuel facilitates combustion of the particulate matter to regenerate the particulate filter.

Gonze, Eugene V. (Pinckney, MI); Brown, David B. (Brighton, MI)

2010-02-02T23:59:59.000Z

355

Removable, hermetically-sealing, filter attachment system for hostile environments  

DOE Patents (OSTI)

A removable and reusable filter attachment system. A filter medium is fixed o, and surrounded by, a filter frame having a coaxial, longitudinally extending, annular rim. The rim engages an annular groove which surrounds the opening of a filter housing. The annular groove contains a fusible material and a heating mechanism for melting the fusible material. Upon resolidifying, the fusible material forms a hermetic bond with the rim and groove. Remelting allows detachment and replacement of the filter frame.

Mayfield, Glenn L. (Richland, WA)

1983-01-01T23:59:59.000Z

356

A Statistical Investigation of the Sensitivity of Ensemble-Based Kalman Filters to Covariance Filtering  

Science Conference Proceedings (OSTI)

This paper investigates the effects of spatial filtering on the ensemble-based estimate of the background error covariance matrix in an ensemble-based Kalman filter (EnKF). In particular, a novel kernel smoothing method with variable bandwidth is ...

Mikyoung Jun; Istvan Szunyogh; Marc G. Genton; Fuqing Zhang; Craig H. Bishop

2011-09-01T23:59:59.000Z

357

Performance Analysis of DS Signal Code Acquisition Using the Matched Filter and the Median Filter  

Science Conference Proceedings (OSTI)

The theoretical analysis and simulation of the performance of a matched filter code acquisition structure with a median filter as the aiding device to cancel CW jamming in the AWGN channel is described. Both coherent and noncoherent structures are ... Keywords: interference cancellation, synchronization

J. Iinatti; P. Leppänen

1998-09-01T23:59:59.000Z

358

Development of Self-destructing Filter Cake  

E-Print Network (OSTI)

The main goal of drilling a horizontal well is to enhance productivity or injectory by placing a long distance drain-hole within the pay-zone. Poor drilling fluid design results in difficulties such as poor hole cleaning, excessive torque or drag, wellbore instability, stuck drill string, loss of circulation, subsurface pressure control, poor cement jobs, and difficulties associated with running electric logs and formation damage can result. Neither of the conventional chemical cleaning methods can overcome problems for filter-cake removal in long horizontal and maximum reservoir contact wells because of limitations such as the complex geometry of wells, non-uniform chemical distribution, low contact between cleaning fluids/filter cake, and high chemical reaction rate, especially at high temperatures. This study describes a novel self-destructing drilling fluid system. Filter cakes are formed from a formula of drilling fluid that have a mixture of solid acid precursor and particulate solid acid-reactive materials. Then in the presence of water, the solid acid precursor (polylactic acid) hydrolyzes and dissolves, generating acids that then dissolve the solid acid-reactive materials (calcite). It effectively stimulates the horizontal section right after drilling and eliminates acidizing, resulting in significant cost savings, and improves filter-cake removal, thus enhancing the performance of the treated wells. A series of experiments have been run in the lab to determine the efficiency of this new system. Properties of this drilling fluid are measured. Experiments on solid acid particle size showed that the best size-distribution of solid acid precursor and solid reactive material to make a self-destructing filter cake is fine particles of calcium carbonate used as weighting material with 150 microns polylactic acid as solid acid precursor. By comparison of the results of the experiments at different temperatures, 230 degrees F has been chosen as the best temperature for running experiments. The self-destructing drilling fluid systems need enough time for the solid acid to be hydrolyzed and therefore remove the filter cake. After 20 hours of contact with the water as the only cleaning solution, about 80 percent of the filter cake was removed. Calcite is found to be the dominant compound in the sample of remained filter cake, which was proved by x-ray diffraction tests. Secondary electron microscopy (SEM) results show the morphology of the remained filter cake sample and confirm the crystalline area of calcite.

Rostami, Ameneh

2010-08-01T23:59:59.000Z

359

Technical Basis for Averaging C-14 Filters, Interim Report: Carbon-14 Source Term Analysis for Encapsulated Filter Waste Forms  

Science Conference Proceedings (OSTI)

The number of power plants implementing submicron-size cartridge filters has increased with the incentive of radiation dose reduction. However, utilities are experiencing difficulty disposing of these filters due to significant increases in (14)C concentrations. This study provides an important technical basis for concentration averaging of encapsulated filters with the grouting of filter waste. The concentration averaging with grouting will save costs in disposal of Greater than Class C filters and will...

2000-11-07T23:59:59.000Z

360

Fuel Cell Technologies Office: Technology Validation  

NLE Websites -- All DOE Office Websites (Extended Search)

Fuel Cell Technologies Office: Technology Validation to someone by E-mail Share Fuel Cell Technologies Office: Technology Validation on Facebook Tweet about Fuel Cell Technologies...

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Automated Collaborative Filtering Applications for Online Recruitment Services  

E-Print Network (OSTI)

. Online recruitment services suffer from shortcomings due to traditional search techniques. Most users fail to construct queries that provide an adequate and accurate description of their (job) requirements, leading to imprecise search results. We investigate one potential solution that combines implicit profiling methods and automated collaborative filtering (ACF) techniques to build personalised query-less job recommendations. Two ACF strategies are implemented and evaluated in the JobFinder domain. 1 Introduction Online recruitment services have emerged as one of the most successful and popular information services on the Internet, providing job seekers with a comprehensive database of jobs and a dedicated search engine. For example, the award-winning Irish site, JobFinder (www.jobfinder.ie). However, like many similar Internet applications JobFinder suffers from shortcomings, due to its reliance on traditional database technology and the client-pull information access mode...

Rachael Rafter; Keith Bradley; Barry Smyth

2000-01-01T23:59:59.000Z

362

Hot gas filter and system assembly  

DOE Patents (OSTI)

A filter element for separating fine dirty particles from a hot gas. The filter element comprises a first porous wall and a second porous wall. Each porous wall has an outer surface and an inner surface. The first and second porous walls being coupled together thereby forming a substantially closed figure and open at one end. The open end is formed to be coupled to a hot gas clean up system support structure. The first and second porous walls define a channel beginning at the open end and terminate at the closed end through which a filtered clean gas can flow through and out into the clean gas side of a hot gas clean up system.

Lippert, Thomas Edwin (Murrysville, PA); Palmer, Kathryn Miles (Monroeville, PA); Bruck, Gerald Joseph (Murrysville, PA); Alvin, Mary Anne (Pittsburgh, PA); Smeltzer, Eugene E. (Export, PA); Bachovchin, Dennis Michael (Murrysville, PA)

1999-01-01T23:59:59.000Z

363

Secondary Pollutants from Ozone Reaction with Ventilation Filters and Degradation of Filter Media Additives  

SciTech Connect

Prior research suggests that chemical processes taking place on the surface of particle filters employed in buildings may lead to the formation of harmful secondary byproducts. We investigated ozone reactions with fiberglass, polyester, cotton/polyester and polyolefin filter media, as well as hydrolysis of filter media additives. Studies were carried out on unused media, and on filters that were installed for 3 months in buildings at two different locations in the San Francisco Bay Area. Specimens from each filter media were exposed to {approx}150 ppbv ozone in a flow tube under a constant flow of dry or humidified air (50percent RH). Ozone breakthrough was recorded for each sample over periods of {approx}1000 min; the ozone uptake rate was calculated for an initial transient period and for steady-state conditions. While ozone uptake was observed in all cases, we did not observe significant differences in the uptake rate and capacity for the various types of filter media tested. Most experiments were performed at an airflow rate of 1.3 L/min (face velocity = 0.013 m/s), and a few tests were also run at higher rates (8 to 10 L/min). Formaldehyde and acetaldehyde, two oxidation byproducts, were quantified downstream of each sample. Those aldehydes (m/z 31 and 45) and other volatile byproducts (m/z 57, 59, 61 and 101) were also detected in real-time using Proton-Transfer Reaction - Mass Spectrometry (PTR-MS). Low-ppbv byproduct emissions were consistently higher under humidified air than under dry conditions, and were higher when the filters were loaded with particles, as compared with unused filters. No significant differences were observed when ozone reacted over various types of filter media. Fiberglass filters heavily coated with impaction oil (tackifier) showed higher formaldehyde emissions than other samples. Those emissions were particularly high in the case of used filters, and were observed even in the absence of ozone, suggesting that hydrolysis of additives, rather than ozonolysis, is the main formaldehyde source in those filters. Emission rates of formaldehyde and acetaldehyde were not found to be large enough to substantially increase indoor concentrations in typical building scenarios. Nevertheless, ozone reactions on HVAC filters cannot be ignored as a source of low levels of indoor irritants.

Destaillats, Hugo; Chen, Wenhao; Apte, Michael; Li, Nuan; Spears, Michael; Almosni, Jérémie; Brunner, Gregory; Zhang, Jianshun (Jensen); Fisk, William J.

2011-05-01T23:59:59.000Z

364

Electrically heated particulate filter with reduced stress  

DOE Patents (OSTI)

A system comprises a particulate matter (PM) filter comprising an inlet for receiving exhaust gas. A zoned heater is arranged in the inlet and comprises a resistive heater comprising N zones, where N is an integer greater than one. Each of the N zones comprises M sub-zones, where M is an integer greater than one. A control module selectively activates one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates others of the N zones.

Gonze, Eugene V.

2013-03-05T23:59:59.000Z

365

Electrically heated particulate filter using catalyst striping  

DOE Patents (OSTI)

An exhaust system that processes exhaust generated by an engine is provided. The system generally includes a particulate filter (PF) that filters particulates from the exhaust wherein an upstream end of the PF receives exhaust from the engine. A grid of electrically resistive material is applied to an exterior upstream surface of the PF and selectively heats exhaust passing through the grid to initiate combustion of particulates within the PF. A catalyst coating is applied to the PF that increases a temperature of the combustion of the particulates within the PF.

Gonze, Eugene V; Paratore, Jr., Michael J; Ament, Frank

2013-07-16T23:59:59.000Z

366

Electrically heated particulate filter enhanced ignition strategy  

DOE Patents (OSTI)

An exhaust system that processes exhaust generated by an engine is provided. The system generally includes a particulate filter (PF) that filters particulates from the exhaust wherein an upstream end of the PF receives exhaust from the engine. A grid of electrically resistive material is applied to an exterior upstream surface of the PF and selectively heats exhaust passing through the grid to initiate combustion of particulates within the PF. A catalyst coating applied to at least one of the PF and the grid. A control module estimates a temperature of the grid and controls the engine to produce a desired exhaust product to increase the temperature of the grid.

Gonze, Eugene V; Paratore, Jr., Michael J

2012-10-23T23:59:59.000Z

367

Particle Image Velocimetry Measurements and Analysis of Bypass Data for a Scaled 6mm Gap  

SciTech Connect

The purpose of the fluid dynamics experiments in the MIR (Matched Index of-Refraction) flow system at Idaho National Laboratory (INL) is to develop benchmark databases for the assessment of Computational Fluid Dynamics (CFD) solutions of the momentum equations, scalar mixing, and turbulence models for the flow ratios between coolant channels and bypass gaps in the interstitial regions of typical prismatic standard fuel element (SFE) or upper reflector block geometries of typical Modular High-temperature Gas-cooled Reactors (MHTGR) in the limiting case of negligible buoyancy and constant fluid properties. The experiments will use optical techniques, primarily particle image velocimetry (PIV) in the INL Matched Index of Refraction (MIR) flow system.

J.R. Wolf; T.E. Conder; R.R. Schultz

2012-09-01T23:59:59.000Z

368

Fabrication of full-scale fiber-reinforced hot-gas filters by chemical vapor depostion. Final report, November 1, 1994 -- December 32, 1995  

SciTech Connect

The overall goal of this contract and its extensions has been to develop a hot gas candle filter which is light weight, has a thin wall, resists mechanical and thermal shock, and is resistive to alkali attack. A ceramic fiber reinforced, ceramic matrix composite approach has been followed to fabricate this new candle filter. Past reports covered the first test results of two ceramic composite candle filters at the Westinghouse Science and Technology Center in March of 1993, subsequent improvements made in the filters construction and fabrication processing, and the testing of six improved full size, 60 mm diameter by 1575 mm length, filters that met or exceeded performance requirements set for them. Completion of the 172 hours of simulated PFBC testing and thermal transients plus maintaining less than 4 ppm clean side ash concentration provided a basis for moving to the next step of testing in the Tidd PFBCC Demonstration Project. In this contract extension 3M fabricated 110 filters to be used for tests in demonstration power plant facilities and other tests that become available. The filters were tested to meet all quality assurance specifications and inventoried for Oak Ridge National Laboratory, ORNL. The filters are being shipped to various industrial, university, and national laboratory test facilities as requested by ORNL. Ten ceramic composite filters were installed in December, 1994 in the Tidd PFBC Demonstration Project filter vessel for their test period No. 5. Five filters were installed in a top cluster and five in a bottom cluster. The filters were removed in May 1995 after operating for 1 1 1 0 hours in a temperature range of 760{degrees}C to 843{degrees}C, with 80% of the run above 815{degrees}C.

Smith, R.G.; Eaton, J.H.; Pysher, D.J.; Leitheiser, M.A.

1996-01-01T23:59:59.000Z

369

Processing Technology  

Science Conference Proceedings (OSTI)

Aug 5, 2013... relevant polymers and hybrid nanocomposite material systems. ... technology to perform lightweight manufacturing of car components.

370

Technology Transfer  

A new search feature has been implemented, which allows searching of technology transfer information across the Department of Energy Laboratories.

371

Technology Transfer  

Science Conference Proceedings (OSTI)

... get started on understanding accessibility in elections and voting technology. ... bibliography was created by the Georgia Tech Research Institute ...

2013-09-17T23:59:59.000Z

372

Parallel Implementation of an Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

Since mid-February 2013, the ensemble Kalman filter (EnKF) in operation at the Canadian Meteorological Centre uses a 600 × 300 global horizontal grid and 74 vertical levels. This yields more than 5 × 107 model coordinates. The EnKF has 192 members ...

P. L. Houtekamer; Bin He; Herschel L. Mitchell

373

Outbound SPIT filter with optimal performance guarantees  

Science Conference Proceedings (OSTI)

This paper presents a formal framework for identifying and filtering SPIT calls (SPam in Internet Telephony) in an outbound scenario with provable optimal performance. In so doing, our work is largely different from related previous work: our goal is ... Keywords: Internet telephony, SPAM, Security, Sequential probability ratio test

Tobias Jung, Sylvain Martin, Mohamed Nassar, Damien Ernst, Guy Leduc

2013-05-01T23:59:59.000Z

374

Commercial Internet filters: Perils and opportunities  

Science Conference Proceedings (OSTI)

Organizations are becoming increasingly aware of Internet abuse in the workplace. Such abuse results in loss of workers' productivity, network congestion, security risks, and legal liabilities. To address this problem, organizations have started to adopt ... Keywords: Internet abuse, Internet filters, Text classification, Text mining

Chen-Huei Chou; Atish P. Sinha; Huimin Zhao

2010-03-01T23:59:59.000Z

375

Automatic image segmentation optimized by bilateral filtering  

Science Conference Proceedings (OSTI)

The object-based methodology is one of the most commonly used strategies for processing high spatial resolution images. A prerequisite to object-based image analysis is image segmentation, which is normally defined as the subdivision of an image into ... Keywords: bilateral filter, image segmentation, self-calibrating framework

Javier Sanchez; Estibaliz Martinez; Agueda Arquero; Diego Renza

2010-11-01T23:59:59.000Z

376

Filter type rotor for multistation photometer  

DOE Patents (OSTI)

A filter type rotor for a multistation photometer is provided. The rotor design combines the principle of cross-flow filtration with centrifugal sedimentation so that these occur simultaneously as a first stage of processing for suspension type fluids in an analytical type instrument. The rotor is particularly useful in whole-blood analysis.

Shumate, II, Starling E. (Knoxville, TN)

1977-07-12T23:59:59.000Z

377

Preemptive Forecasts Using an Ensemble Kalman Filter  

Science Conference Proceedings (OSTI)

An ensemble Kalman filter (EnKF) estimates the error statistics of a model forecast using an ensemble of model forecasts. One use of an EnKF is data assimilation, resulting in the creation of an increment to the first-guess field at the ...

Brian J. Etherton

2007-10-01T23:59:59.000Z

378

Design of Sparse Filters for Channel Shortening  

Science Conference Proceedings (OSTI)

Channel shortening equalizers are used in acoustics to reduce reverberation, in error control decoding to reduce complexity, and in communication receivers to reduce inter-symbol interference. The cascade of a channel and channel shortening equalizer ... Keywords: Channel shortening, Discrete multi-tone modulation, Reverberant channels, Sparse filters, Time-domain equalizers

Aditya Chopra; Brian Lawrence Evans

2012-03-01T23:59:59.000Z

379

QUANTUM STOCHASTIC CALCULUS AND QUANTUM NONLINEAR FILTERING  

E-Print Network (OSTI)

QUANTUM STOCHASTIC CALCULUS AND QUANTUM NONLINEAR FILTERING V. P. BELAVKIN Abstract. A ?­algebraic inde...nite structure of quantum stochastic (QS) cal- culus is introduced and a continuity property...nitely dimensional nuclear space. The class of nondemolition output QS processes in quantum open systems

Belavkin, Viacheslav P.

380

Technology Strategies  

Science Conference Proceedings (OSTI)

From the Book:PrefaceTechnology as the Strategic AdvantageWhen I began writing this book I struggled with the direction I wanted it to take. Is this book to be about business, technology, or even the business of technology? I ...

Cooper Smith

2001-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

The RAW Filter: An Improvement to the Robert–Asselin Filter in Semi-Implicit Integrations  

Science Conference Proceedings (OSTI)

Errors caused by discrete time stepping may be an important component of total model error in contemporary atmospheric and oceanic simulations. To reduce time-stepping errors in leapfrog integrations, the Robert–Asselin–Williams (RAW) filter was ...

Paul D. Williams

2011-06-01T23:59:59.000Z

382

Pulse-Jet Fabric Filter Guidelines: Volume 3, Utility Pulse-Jet Fabric Filters -- Case Studies  

Science Conference Proceedings (OSTI)

Power plants need to reduce stack emissions of mercury, filterable particulate matter (FPM),  and acid gases to comply with the Mercury and Air Toxics Standards (MATS) issued by the U.S. Environmental Protection Agency (EPA) on February 16, 2012. The MATS standard requires that total stack FPM be maintained at < 0.03 lb/MMBtu. As particulate emission regulations become more stringent, the use of baghouses (also known as fabric filters) for particulate control on coal-fired boilers in the ...

2012-12-31T23:59:59.000Z

383

Laboratory measurement of secondary pollutant yields from ozone reaction with HVAC filters.  

E-Print Network (OSTI)

from Ozone Reaction with HVAC Filters Hugo Destaillats,from Ozone Reaction with HVAC Filters Hugo Destaillatsfrom Ozone Reaction with HVAC Filters Hugo Destaillats

Destaillats, Hugo

2012-01-01T23:59:59.000Z

384

Investigation of IAQ-Relevant Surface Chemistry and Emissions on HVAC Filter Materials  

E-Print Network (OSTI)

VOCs emitted by reactions of HVAC filters with ozone usingChemistry and Emissions on HVAC Filter Materials HugoChemistry and Emissions on HVAC Filter Materials Authors:

Destaillats, Hugo

2010-01-01T23:59:59.000Z

385

An Innovative Method for Dynamic Characterization of Fan Filter Unit Operation.  

E-Print Network (OSTI)

Filtration: Fan filter units. Final Report, LawrencePerformance of Fan Filter Units, Version 1.3. ” BerkeleyEfficient Fan filter units,” Proceedings of Semiconductor

Xu, Tengfang

2006-01-01T23:59:59.000Z

386

Integrated optical filters using Bragg gratings and resonators  

E-Print Network (OSTI)

This thesis provides an in-depth study of optical filters made using integrated Bragg gratings and Bragg resonators. Various topologies for making add/drop filters using integrated gratings are outlined. Each class of ...

Khan, Mohammad Jalal

2002-01-01T23:59:59.000Z

387

Parallel Implementation of a Kalman Filter for Constituent Data Assimilation  

Science Conference Proceedings (OSTI)

A Kalman filter for the assimilation of long-lived atmospheric chemical constituents was developed for two-dimensional transport models on isentropic surfaces over the globe. Since the Kalman filter calculates the error covariances of the ...

P. M. Lyster; S. E. Cohn; R. Ménard; L-P. Chang; S-J. Lin; R. G. Olsen

1997-07-01T23:59:59.000Z

388

Coupled-magnetic filters with adaptive inductance cancellation  

E-Print Network (OSTI)

Conventional filter circuits suffer from a number of limitations, including performance degradation due to capacitor parasitic inductance and the size and cost of magnetic elements. Coupled-magnetic filters have been ...

Lymar, Daria S

2005-01-01T23:59:59.000Z

389

Scalable Implementations of Ensemble Filter Algorithms for Data Assimilation  

Science Conference Proceedings (OSTI)

A variant of a least squares ensemble (Kalman) filter that is suitable for implementation on parallel architectures is presented. This parallel ensemble filter produces results that are identical to those from sequential algorithms already ...

Jeffrey L. Anderson; Nancy Collins

2007-08-01T23:59:59.000Z

390

A Non-Gaussian Ensemble Filter Update for Data Assimilation  

Science Conference Proceedings (OSTI)

A deterministic square root ensemble Kalman filter and a stochastic perturbed observation ensemble Kalman filter are used for data assimilation in both linear and nonlinear single variable dynamical systems. For the linear system, the ...

Jeffrey L. Anderson

2010-11-01T23:59:59.000Z

391

The discrete Kalman filtering approach for seismic signals deconvolution  

SciTech Connect

Seismic signals are a convolution of reflectivity and seismic wavelet. One of the most important stages in seismic data processing is deconvolution process; the process of deconvolution is inverse filters based on Wiener filter theory. This theory is limited by certain modelling assumptions, which may not always valid. The discrete form of the Kalman filter is then used to generate an estimate of the reflectivity function. The main advantage of Kalman filtering is capability of technique to handling continually time varying models and has high resolution capabilities. In this work, we use discrete Kalman filter that it was combined with primitive deconvolution. Filtering process works on reflectivity function, hence the work flow of filtering is started with primitive deconvolution using inverse of wavelet. The seismic signals then are obtained by convoluting of filtered reflectivity function with energy waveform which is referred to as the seismic wavelet. The higher frequency of wavelet gives smaller wave length, the graphs of these results are presented.

Kurniadi, Rizal; Nurhandoko, Bagus Endar B. [Departement of Physics Intitut Teknologi Bandung, Jl. Ganesha 10 Bandung (Indonesia)

2012-06-20T23:59:59.000Z

392

Detection of Forced Climate Signals. Part 1: Filter Theory  

Science Conference Proceedings (OSTI)

This paper considers the construction of a linear smoothing filter for estimation of the forced part of a change in a climatological field such as the surface temperature. The filter is optimal in the sense that it suppresses the natural ...

Gerald R. North; Kwang-Y. Kim; Samuel S. P. Shen; James W. Hardin

1995-03-01T23:59:59.000Z

393

A Spatial Filter for Use in Finite Area Calculations  

Science Conference Proceedings (OSTI)

A multidimensional filter which selectively removes 2?x and 2?y noise is introduced. The filter is designed to be effective in finite area models with nonperiodic horizontal boundary conditions. An economical splitting technique, requiring an ...

William H. Raymond; Arthur Garder

1988-01-01T23:59:59.000Z

394

A New Method for Time Series Filtering near Endpoints  

Science Conference Proceedings (OSTI)

Time series filtering (e.g., smoothing) can be done in the spectral domain without loss of endpoints. However, filtering is commonly performed in the time domain using convolutions, resulting in lost points near the series endpoints. Multiple ...

Anthony Arguez; Peng Yu; James J. O’Brien

2008-04-01T23:59:59.000Z

395

Practical gammatone-like filters for auditory processing  

Science Conference Proceedings (OSTI)

This paper deals with continuous-time filter transfer functions that resemble tuning curves at particular set of places on the basilar membrane of the biological cochlea and that are suitable for practical VLSI implementations. The resulting filters ...

2007-10-01T23:59:59.000Z

396

Extended versus Ensemble Kalman Filtering for Land Data Assimilation  

Science Conference Proceedings (OSTI)

The performance of the extended Kalman filter (EKF) and the ensemble Kalman filter (EnKF) are assessed for soil moisture estimation. In a twin experiment for the southeastern United States synthetic observations of near-surface soil moisture are ...

Rolf H. Reichle; Jeffrey P. Walker; Randal D. Koster; Paul R. Houser

2002-12-01T23:59:59.000Z

397

Preparation of Metal Filter Element for Fail Safety in IGCC Filter Unit  

SciTech Connect

Metal filter elements as the fail safety filter are fabricated by the methods using cold isostatic pressure (compress method) and binder (binder method) to form the filter element and tested in a experimental and bench units. The fail safety filter on the filtration system is mounted additionally in order to intercept the particle leak when the main filter element is broken. So it should have two contrary functions of a high permeability and being plugged easily. The filter element having high porosity and high plugging property was fabricated by the bind method. It has the porosity more than 50%, showed very small pressure drop less than 10mmH2O at the face velocity of 0.15m/s, and plugged within 5 minutes with the inhibition of the particle leak larger than 4 {micro}m. The test result of corrosion tendency in IGCC gas stream at 500 C shows SUS310L material is very reasonable among SUS310, SUS316, Inconel 600, and Hastelloy X.

Choi, J-H.; Ahn, I-S.; Bak, Y-C.; Bae, S-Y.; Ha, S-J.; Jang, H-J.

2002-09-18T23:59:59.000Z

398

Direct-energy-regenerated particulate trap technology. Final report  

DOE Green Energy (OSTI)

The objective of this CRADA between Lockheed Martin and Cummins Engine Company was to develop fiber-reinforced silicon carbide (SiC) composite materials for use as diesel engine particulate traps. Chemical vapor deposition techniques were used to partially densify and rigidize a thin fibrous substrate and produce the porous SiC- based filter. Microwave energy was used to directly couple to the deposited SiC to uniformly heat the filter and oxidize the collected carbon particulates. For commercial usage particulate traps must: (1) filter carbon particulates from a high temperature diesel exhaust at an acceptably low backpressure, (2) survive thousands of thermal transients due to regeneration or cleaning of the filter by oxidizing the collected carbon, (3) be durable and reliable over the expected life of the filter (300,000 miles or 10,000 hours), and (4) provide a low overall operating cost which is competitive with other filtering techniques. The development efforts performed as part of this CRADA have resulted in a very promising new technology for Cummins Engine Company. Ceramic fiber based filter papers were developed at Fleetguard, Inc., (a Cummins Subsidiary) and used to produce the spiral wound, corrugated filter cartridges. Optimized SiC coatings were developed at Lockheed Martin which couple with 2.45 GHz microwaves. Prototype particulate filter cartridges fabricated at Fleetguard and rigidized at Lockheed Martin performed well in single cylinder engine tests at Cummins. These prototype filters obtained filtering efficiencies greater than 80% at acceptably low backpressures and could be successfully headed and regenerated using a conventional in-home microwave oven.

Stinton, D.P.; Janney, M.A. [Oak Ridge National Lab., TN (United States); Yonushonis, T.M.; McDonald, A.C.; Wiczynski, P.D. [Cummins Engine Co., Inc., Columbus, IN (United States); Haberkamp, W.C. [Fleetguard, Inc. (United States)

1996-12-01T23:59:59.000Z

399

Fuel Property, Emission Test, and Operability Results from a Fleet of Class 6 Vehicles Operating on Gas-to-Liquid Fuel and Catalyzed Diesel Particle Filters  

DOE Green Energy (OSTI)

A fleet of six 2001 International Class 6 trucks operating in southern California was selected for an operability and emissions study using gas-to-liquid (GTL) fuel and catalyzed diesel particle filters (CDPF). Three vehicles were fueled with CARB specification diesel fuel and no emission control devices (current technology), and three vehicles were fueled with GTL fuel and retrofit with Johnson Matthey's CCRT diesel particulate filter. No engine modifications were made.

Alleman, T. L.; Eudy, L.; Miyasato, M.; Oshinuga, A.; Allison, S.; Corcoran, T.; Chatterjee, S.; Jacobs, T.; Cherrillo, R. A.; Clark, R.; Virrels, I.; Nine, R.; Wayne, S.; Lansing, R.

2005-11-01T23:59:59.000Z

400

Electrically heated particulate filter propagation support methods and systems  

Science Conference Proceedings (OSTI)

A control system that controls regeneration of a particulate filter is provided. The system generally includes a regeneration module that controls current to the particulate filter to initiate combustion of particulate matter in the particulate filter. A propagation module estimates a propagation status of the combustion of the particulate matter based on a combustion temperature. A temperature adjustment module controls the combustion temperature by selectively increasing a temperature of exhaust that passes through the particulate filter.

Gonze, Eugene V [Pinckney, MI; Ament, Frank [Troy, MI

2011-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Independent component analysis based filtering for penumbral imaging  

Science Conference Proceedings (OSTI)

We propose a filtering based on independent component analysis (ICA) for Poisson noise reduction. In the proposed filtering, the image is first transformed to ICA domain and then the noise components are removed by a soft thresholding (shrinkage). The proposed filter, which is used as a preprocessing of the reconstruction, has been successfully applied to penumbral imaging. Both simulation results and experimental results show that the reconstructed image is dramatically improved in comparison to that without the noise-removing filters.

Chen Yenwei; Han Xianhua; Nozaki, Shinya [College of Information Science and Engineering, Ritsumeikan University, Shiga 525-8577 (Japan); Institute of Computational Science and Engineering, Ocean University of China, Shandong (China); Faculty of Engineering, University of the Ryukyus, Okinawa 903-0213 (Japan); Okinawa National College of Technology, Okinawa (Japan)

2004-10-01T23:59:59.000Z

402

Results from tests of DuPont crossflow filter  

SciTech Connect

Crossflow filtration will be used to filter radioactive waste slurry as part of the Late Wash Process.

Steimke, J.L.

2000-05-05T23:59:59.000Z

403

Microstrip filters for measurement and control of superconducting qubits  

E-Print Network (OSTI)

Careful filtering is necessary for observations of quantum phenomena in superconducting circuits at low temperatures. Measurements of coherence between quantum states requires extensive filtering to protect against noise coupled from room temperature electronics. We demonstrate distributed transmission line filters which cut off exponentially at GHz frequencies and can be anchored at the base temperature of a dilution refrigerator. The compact design makes them suitable to filter many different bias lines in the same setup, necessary for the control and measurement of superconducting qubits.

Longobardi, Luigi; Patel, Vijay; Chen, Wei; Lukens, James E

2013-01-01T23:59:59.000Z

404

Technology '90  

Science Conference Proceedings (OSTI)

The US Department of Energy (DOE) laboratories have a long history of excellence in performing research and development in a number of areas, including the basic sciences, applied-energy technology, and weapons-related technology. Although technology transfer has always been an element of DOE and laboratory activities, it has received increasing emphasis in recent years as US industrial competitiveness has eroded and efforts have increased to better utilize the research and development resources the laboratories provide. This document, Technology '90, is the latest in a series that is intended to communicate some of the many opportunities available for US industry and universities to work with the DOE and its laboratories in the vital activity of improving technology transfer to meet national needs. Technology '90 is divided into three sections: Overview, Technologies, and Laboratories. The Overview section describes the activities and accomplishments of the DOE research and development program offices. The Technologies section provides descriptions of new technologies developed at the DOE laboratories. The Laboratories section presents information on the missions, programs, and facilities of each laboratory, along with a name and telephone number of a technology transfer contact for additional information. Separate papers were prepared for appropriate sections of this report.

Not Available

1991-01-01T23:59:59.000Z

405

A mutual information extension to the matched filter  

Science Conference Proceedings (OSTI)

Matched filters are the optimal linear filters for signal detection under linear channel and white noise conditions. Their optimality is guaranteed in the additive white Gaussian noise channel due to the sufficiency of second-order statistics. In this ... Keywords: matched filter, mutual information, nonlinear distortion, signal detection

Deniz Erdogmus; Rati Agrawal; Jose C. Principe

2005-05-01T23:59:59.000Z

406

Atmospheric Environment 41 (2007) 31513160 Ozone removal by HVAC filters  

E-Print Network (OSTI)

Atmospheric Environment 41 (2007) 3151­3160 Ozone removal by HVAC filters P. Zhao, J.A. Siegel�, R May 2006; accepted 14 June 2006 Abstract Residential and commercial HVAC filters that have been loaded of the relative importance of HVAC filters as a removal mechanism for ozone in residential and commercial

Siegel, Jeffrey

407

A unified method for optimizing linear image restoration filters  

Science Conference Proceedings (OSTI)

Image restoration from degraded images lies at the foundation of image processing, pattern recognition, and computer vision, so it has been extensively studied. A large number of image restoration filters have been devised so far. It is known that a ... Keywords: denoising, image restoration, linear filter, moving-average filter, subspace information criterion (SIC)

Masashi Sugiyama; Hidemitsu Ogawa

2002-11-01T23:59:59.000Z

408

Kalman-type positioning filters with floor plan information  

Science Conference Proceedings (OSTI)

A family of Kalman-type filters that estimate the user's position indoors, using range measurements and floor plan data, is presented. The floor plan information is formulated as a set of linear constraints and is used to truncate the Gaussian posterior ... Keywords: Kalman filter, floor plan, inequality constraints, nonlinear filtering, positioning

Tommi Perälä; Simo Ali-Löytty

2008-11-01T23:59:59.000Z

409

Reduced-rank adaptive filtering using Krylov subspace  

Science Conference Proceedings (OSTI)

A unified view of several recently introduced reduced-rank adaptive filters is presented. As all considered methods use Krylov subspace for rank reduction, the approach taken in this work is inspired from Krylov subspace methods for iterative solutions ... Keywords: Krylov subspace methods, adaptive filters, array processing, multiuser detection, reduced-rank adaptive filters

Sergueï Burykh; Karim Abed-Meraim

2002-01-01T23:59:59.000Z

410

An early decision algorithm to accelerate web content filtering  

Science Conference Proceedings (OSTI)

Real-time content analysis can be a bottleneck in Web filtering This work presents a simple, but effective early decision algorithm to accelerate the filtering process by examining only part of the Web content The algorithm can make the filtering decision, ...

Po-Ching Lin; Ming-Dao Liu; Ying-Dar Lin; Yuan-Cheng Lai

2006-01-01T23:59:59.000Z

411

Electrically heated particulate filter preparation methods and systems  

SciTech Connect

A control system that controls regeneration of a particulate filter is provided. The system generally includes a fuel control module that controls injection of fuel into exhaust that passes through the particulate filter. A regeneration module controls current to the particulate filter to initiate regeneration after the fuel has been injected into the exhaust.

Gonze, Eugene V [Pinckney, MI

2012-01-31T23:59:59.000Z

412

Adaptive filtering with bandwidth constraints in the feedback path  

Science Conference Proceedings (OSTI)

This paper introduces a new, adaptive-filter-based controller that shows advantageous properties from the viewpoint of its communication requirement. The algorithm is called signed-error filtered-x LMS (SE-FxLMS). Its novelty is characterized by the ... Keywords: Adaptive filter based controller, FxLMS algorithm, Networked control systems, Signed-error algorithm, Wireless control

György Orosz; László Sujbert; Gábor Péceli

2012-01-01T23:59:59.000Z

413

Fracture behavior of advanced ceramic hot gas filters: Final report  

SciTech Connect

This report presents the results of mechanical/microstructural evaluation, thermal shock/fatigue testing, and stress analyses of advanced hot-gas filters obtained from different manufacturers. These filters were fabricated from both monolithic ceramics and composites. The composite filters, made of both oxide and nonoxide materials, were in both as-fabricated and exposed conditions, whereas the monolithic filters were made only of nonoxide materials. Mechanical property measurement of composite filters included diametral compression testing with O-ring specimens and burst-testing of short filter segments with rubber plugs. In-situ strength of fibers in the composite filters was evaluated by microscopic technique. Thermal shock/fatigue resistance was estimated by measuring the strengths of filter specimens before and after thermal cycling from an air environment at elevated temperatures to a room temperature oil bath. Filter performance during mechanical and thermal shock/fatigue loadings was correlated with microstructural observations. Micromechanical models were developed to derive properties of composite filter constituents on the basis of measured mechanical properties of the filters. Subsequently, these properties were used to analytically predict the performance of composite filters during thermal shock loading.

Singh, J.P.; Majumdar, S.; Sutaria, M.; Bielke, W. [Argonne National Lab., IL (United States). Energy Technology Div.

1997-03-01T23:59:59.000Z

414

Optimizing performance of ceramic pot filters in Northern Ghana and modeling flow through paraboloid-shaped filters/  

E-Print Network (OSTI)

This work aimed to inform the design of ceramic pot filters to be manufactured by the organization Pure Home Water (PHW) in Northern Ghana, and to model the flow through an innovative paraboloid-shaped ceramic pot filter. ...

Miller, Travis Reed

2010-01-01T23:59:59.000Z

415

Building Technologies Office: Technology Research, Standards...  

NLE Websites -- All DOE Office Websites (Extended Search)

to someone by E-mail Share Building Technologies Office: Technology Research, Standards, and Codes in Emerging Technologies on Facebook Tweet about Building Technologies...

416

Recent Lidar Technology Developments and Their Influence on Measurements of Tropospheric Water Vapor  

Science Conference Proceedings (OSTI)

In this paper the influences of recent technology developments in the areas of lasers, detectors, and optical filters of a differential absorption lidar (DIAL) system on the measurement of tropospheric water vapor (H20) profiles are discussed. ...

Syed Ismail; Edward V. Browell

1994-02-01T23:59:59.000Z

417

Available Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

6 News Stories (and older) 6 News Stories (and older) 12.21.2005___________________________________________________________________ Genzyme acquires gene therapy technology invented at Berkeley Lab. Read more here. 07.19.2005 _________________________________________________________________ Symyx, a start up company using Berkeley Lab combinatorial chemistry technology licensed by the Technology Transfer Department and developed by Peter Schultz and colleagues in the Materials Sciences Division, will be honored with Frost & Sullivan's 2005 Technology Leadership Award at their Excellence in Emerging Technologies Awards Banquet for developing enabling technologies and methods to aid better, faster and more efficient R&D. Read more here. 07.11.2005 _________________________________________________________________ Nanosys, Inc., a Berkeley Lab startup, is among the solar nanotech companies investors along Sand Hill Road in Menlo Park hope that thinking small will translate into big profits. Read more here.

418

Overlap zoned electrically heated particulate filter  

DOE Patents (OSTI)

A system includes a particulate matter (PM) filter that includes an upstream end for receiving exhaust gas and a downstream end. A zoned heater is arranged spaced from the upstream end and comprises N zones, where N is an integer greater than one, wherein each of the N zones comprises M sub-zones, where M is an integer greater than or equal to one, and wherein the N zones and the M sub-zones are arranged in P layers, where P is an integer greater than one. A control module selectively activates at least a selected one of the N zones to initiate regeneration in downstream portions of the PM filter from the one of the N zones and deactivates non-selected ones of the N zones.

Gonze, Eugene V [Pinckney, MI; Chapman, Mark R [Brighton, MI

2011-07-19T23:59:59.000Z

419

Fast adaptive elliptical filtering using box splines  

E-Print Network (OSTI)

We demonstrate that it is possible to filter an image with an elliptic window of varying size, elongation and orientation with a fixed computational cost per pixel. Our method involves the application of a suitable global pre-integrator followed by a pointwise-adaptive localization mesh. We present the basic theory for the 1D case using a B-spline formalism and then appropriately extend it to 2D using radially-uniform box splines. The size and ellipticity of these radially-uniform box splines is adaptively controlled. Moreover, they converge to Gaussians as the order increases. Finally, we present a fast and practical directional filtering algorithm that has the capability of adapting to the local image features.

Chaudhury, Kunal Narayan; Unser, Michael

2009-01-01T23:59:59.000Z

420

Combined cycle electric power plant with a steam turbine having a sliding pressure main bypass and control valve system  

SciTech Connect

A combined cycle electric power plant includes two gas turbines, a steam turbine, and a digital control system with an operator analog or manual backup. Each of the gas turbines has an exhaust heat recovery steam generator connected to a common header from which the steam is supplied by one or both of the steam generators for operating the steam turbine. The control system is of the sliding pressure type and maintains a predetermined steam pressure as a function of steam flow according to a predetermined characterization depending on the number of steam generators in service to limit the maximum steam velocity through the steam generators, and reduce the probability of water carryover into the steam turbine. Such control is always maintained by the bypass valve. The turbine control valve responds to the speed/load demand only, except when the bypass valve is closed and the rate of steam generation is insufficient to maintain a predetermined pressure flow relationship.

Uram, R.

1980-05-06T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Alpha migration through air filters: A numerical simulation  

Science Conference Proceedings (OSTI)

This theoretical study investigates the migration of alpha-emitting particles through high-efficiency particulate air (HEPA) filters. As part of the study, a review of previous research relating to the alpha-migration phenomena was conducted. As a result of the literature review, a numerical model was developed to simulate the migration of alpha-emitting radionuclide aerosols through HEPA filters. This model predicts the filter performance with regard to particle penetration. It can be used to better estimate the penetration of alpha radioactive species through filter systems for environmental concerns, to aid in the use of current filter systems, and to design new filter systems. It is obvious from the review of the literature that evidence exists of migration of alpha radionuclide species through high-efficiency filter media. The theories suggest that nanometer-size particles can eventually penetrate fibrous filters because of gradual movement through the filter matrix. It is conjectured that this movement may be induced by energies caused by the alpha recoil from the decay process by thermal energies. It is further hypothesized that such nanometer-size particles, containing radionuclide species can be formed from larger particles already captured within the filter. The penetration of such small particles through high-efficiency filter media is so low that experimental corroboration of these mechanisms by penetration measurements is difficult at best. A number of items were identified that affect the migration of alpha-emitting particles through a filter. These include the size distribution of aerosol particles entering the filter, the size distribution of fragment particles produced by alpha recoil, the penetration of the challenge aerosols and fragment particles, the velocity through the filter, the radionuclide specific activity, the alpha recoil energy, and the surface-binding energies between the particle and the filter matrix.

Biermann, A.H.; da Roza, R.A.; Chang, Yun.

1991-12-11T23:59:59.000Z

422

NETL: Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

projects are designed to: enhance domestic oil and natural gas supplies through advanced exploration and production technology; examine water related concerns; investigate...

423

Technology Update  

Science Conference Proceedings (OSTI)

A Novel Solvent Extraction Process With Bottom Gas Injection for Liquid Waste ... Membrane Technology for Treatment of Wastes Containing Dissolved Metals: ...

424

Microwave Technology  

Science Conference Proceedings (OSTI)

Oct 20, 2011 ... These wastes are found in the market. ... Cherian1; Michael Kirksey1; Sandwip Dey2; 1Spheric Technologies Inc; 2Arizona State University

425

Transmission Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

electronically (shift-by-wire) and performed by a hydraulic system or electric motor. In addition, technologies can be employed to make the shifting process smoother than...

426

Compact cyclone filter train for radiological and hazardous environments  

DOE Patents (OSTI)

A compact cyclone filter train is disclosed for the removal of hazardous and radiological particles from a gaseous fluid medium. This filter train permits a small cyclone separator to be used in a very small space envelope due to the arrangement of the filter housing adjacent to the separator with the cyclone separator and the filters mounted on a plate. The entire unit will have a hoist connection at the center of gravity so that the entire unit including the separator, the filters, and the base can be lifted and repositioned as desired. 3 figs.

Bench, T.R.

1998-04-28T23:59:59.000Z

427

Guenter Tulip Filter Retrieval Experience: Predictors of Successful Retrieval  

Science Conference Proceedings (OSTI)

We report our experience with Guenter Tulip filter placement indications, retrievals, and procedural problems, with emphasis on alternative retrieval techniques. We have identified 92 consecutive patients in whom a Guenter Tulip filter was placed and filter removal attempted. We recorded patient demographic information, filter placement and retrieval indications, procedures, standard and nonstandard filter retrieval techniques, complications, and clinical outcomes. The mean time to retrieval for those who experienced filter strut penetration was statistically significant [F(1,90) = 8.55, p = 0.004]. Filter strut(s) IVC penetration and successful retrieval were found to be statistically significant (p = 0.043). The filter hook-IVC relationship correlated with successful retrieval. A modified guidewire loop technique was applied in 8 of 10 cases where the hook appeared to penetrate the IVC wall and could not be engaged with a loop snare catheter, providing additional technical success in 6 of 8 (75%). Therefore, the total filter retrieval success increased from 88 to 95%. In conclusion, the Guenter Tulip filter has high successful retrieval rates with low rates of complication. Additional maneuvers such as a guidewire loop method can be used to improve retrieval success rates when the filter hook is endothelialized.

Turba, Ulku Cenk, E-mail: uct5d@virginia.edu; Arslan, Bulent, E-mail: ba6e@virginia.edu; Meuse, Michael, E-mail: mm5tz@virginia.edu; Sabri, Saher, E-mail: ss2bp@virginia.ed [University of Virginia, Health System Foundation, Department of Radiology (United States); Macik, Barbara Gail, E-mail: bgm3s@virginia.ed [University of Virginia, Health System Foundation, Department of Internal Medicine/Hematology (United States); Hagspiel, Klaus D., E-mail: kdh2n@virginia.edu; Matsumoto, Alan H., E-mail: ahm4d@virginia.edu; Angle, John F., E-mail: jfa3h@virginia.ed [University of Virginia, Health System Foundation, Department of Radiology (United States)

2010-08-15T23:59:59.000Z

428

Method of recovering hazardous waste from phenolic resin filters  

DOE Patents (OSTI)

A method has been found for treating phenolic resin filter, whereby the filter is solubilized within the filter cartridge housing so the filter material can be removed from the cartridge housing in a remote manner. The invention consists of contacting the filter within the housing with an aqueous solution of about 8 to 12M nitric acid, at a temperature from about 110 to 190{degree}F, maintaining the contact for a period of time sufficient to solubilize the phenolic material within the housing, and removing the solubilized phenolic material from the housing, thereby removing the filter cartridge from the housing. Any hazardous or other waste material can then be separated from the filter material by chemical or other means.

Meikrantz, D.H.; Bourne, G.L.; McFee, J.N.; Burdge, B.G.; McConnell, J.W. Jr.

1990-12-31T23:59:59.000Z

429

Metering Technology  

Science Conference Proceedings (OSTI)

Utilities are looking to replace meters that only measure kilowatt-hours with advanced meters with greater features and functions. This White Paper describes the smart metering technology that is already available or will be available in the near future. It also provides a high-level overview of the wired and wireless communication technologies used in the metering industry.

2008-06-20T23:59:59.000Z

430

NETL: Combustion Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

Detailed Description of APFBC Repowering Detailed Description of APFBC Repowering FBC Repower Simple Description Detailed Description APFBC Specs GTs for APFBC Click on picture to enlarge Repowering Existing Power Plants with Advanced Pressurized Fluidized-Bed Combined Cycles Contents: Please send me to the NON-TECHNICAL DISCUSSION about APFBC instead! Click on the technical discussion areas below, or simply browse down in this page: APFBC Repowering Considerations Process Sketch APFBC Components High Energy Efficiency Excellent Environmental Performance Cost Comparable to a Pulverized Coal Plant APFBC Repowering Considerations Click on picture to enlarge Process Sketch While all elements of the APFBC plant have been tested, APFBC technology is still under development. Test programs are in place that will soon show commercial operations for all parts. The most important of these are the DOE Power Systems Development Facility in Wilsonville, Alabama, and two DOE Clean Coal Technology projects: Piñon Pines, testing ceramic filters, and the APFBC CCT project. DOE views the following as the development status of the various elements for application in a year 2002 repowering plant installation:

431

NETL: Technology Transfer - Available Technologies for Partnership  

6,468,499: Method of generating hydrogen by catalytic decomposition of water: 6,056,796: Rigid Porous Filter: 6,056,125: Cross Flow Cyclonic Flotation ...

432

Technology Search Results | Brookhaven Technology ...  

BSA 11-30: Enhanced Alkane production by Aldehyde Decarbonylase Fusion Constructs; BSA 12-36: Oil Accumulation in Plant Leaves; Find a Technology.

433

Technology Search Results | Brookhaven Technology ...  

There are 9 technologies tagged "cancer". BSA 01-02: ... a limited-liability company founded by the Research Foundation for the State University of ...

434

Manufacturing Science and Technology: Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

Courtesy of ZCorp The Rapid Prototyping Laboratory (RPL) supports internal design, manufacturing, and process development with three rapid prototyping (RP) technologies:...

435

Manufacturing Science and Technology: Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

parts Brazing large complex parts The joining and heat-treating technologies in the Thin Film, Vacuum, & Packaging department include brazing, heat-treating, diffusion...

436

Integrated reservoir characterization of a Tulare steamflood finds bypassed oil - South Belridge Field, Kern County, California  

SciTech Connect

Reservoir quality and producibility are directly related to the characteristics of the depositional lithofacies. Electric log gamma ray/resistivity profiles were used to define facies trends within the Tulare steamflood at South Belridge. Channel and non-channel facies profiles are distinctive across the lease with the channel sands having the better quality reservoir and greater net pay values. Sidewall core permeabilities were averaged over the main producing Tulare intervals with the channels averaging 2000-3000 millidarcies and non-channels 200-500 millidarcies. This supports the lithofacies trend and net pay maps. Although the approach is qualitative, it illustrates the dramatic permeability contrast between the channel and non-channel lithofacies. Temperature maps using downhole temperature surveys and flowline temperatures indicate channel facies temperatures up to 300[degrees] with the non-channel facies having 90[degrees] to 100[degrees] temperatures (near ambient). Higher temperatures also relate to higher average daily production rates for channel associated wells. Channel wells averaged greater than 30 BOPD while non-channel wells averaged 10 BOPD or less. New and replacement well nations have been high graded resulting in favorable production responses. Integration of the lithofacies, permeability and temperature data plus ongoing preventive production optimization work has led to a more efficient Tulare steamflood and identification of bypassed oil on the King-Ellis lease in the South Belridge Field.

Walter, D.R.; Wylie, A.S. Jr.; Broussard, K.A. (Santa Fe Energy Resources, Bakersfield, CA (United States))

1996-01-01T23:59:59.000Z

437

Edge preserving orientation adaptive filtering P. Bakker, L.J. van Vliet, P.W. Verbeek  

E-Print Network (OSTI)

Edge preserving orientation adaptive filtering P. Bakker, L.J. van Vliet, P.W. Verbeek Pattern for combining orientation adaptive filtering and edge preserving filtering. The filter adapts to the local orientation and avoids filter- ing across borders. The local orientation for steering the filter

van Vliet, Lucas J.

438

Vehicle Technologies Office: Graduate Automotive Technology Education  

NLE Websites -- All DOE Office Websites (Extended Search)

Deployment Deployment Site Map Printable Version Share this resource Send a link to Vehicle Technologies Office: Graduate Automotive Technology Education (GATE) to someone by E-mail Share Vehicle Technologies Office: Graduate Automotive Technology Education (GATE) on Facebook Tweet about Vehicle Technologies Office: Graduate Automotive Technology Education (GATE) on Twitter Bookmark Vehicle Technologies Office: Graduate Automotive Technology Education (GATE) on Google Bookmark Vehicle Technologies Office: Graduate Automotive Technology Education (GATE) on Delicious Rank Vehicle Technologies Office: Graduate Automotive Technology Education (GATE) on Digg Find More places to share Vehicle Technologies Office: Graduate Automotive Technology Education (GATE) on AddThis.com...

439

Building Technologies Office: Emerging Technologies Activities  

NLE Websites -- All DOE Office Websites (Extended Search)

Emerging Technologies Emerging Technologies Activities to someone by E-mail Share Building Technologies Office: Emerging Technologies Activities on Facebook Tweet about Building Technologies Office: Emerging Technologies Activities on Twitter Bookmark Building Technologies Office: Emerging Technologies Activities on Google Bookmark Building Technologies Office: Emerging Technologies Activities on Delicious Rank Building Technologies Office: Emerging Technologies Activities on Digg Find More places to share Building Technologies Office: Emerging Technologies Activities on AddThis.com... About Take Action to Save Energy Partner with DOE Activities Appliances Research Building Envelope Research Windows, Skylights, & Doors Research Space Heating & Cooling Research Water Heating Research

440

Vehicle Technologies Office: Vehicle Technologies Office Recognizes  

NLE Websites -- All DOE Office Websites (Extended Search)

Vehicle Technologies Vehicle Technologies Office Recognizes Outstanding Researchers to someone by E-mail Share Vehicle Technologies Office: Vehicle Technologies Office Recognizes Outstanding Researchers on Facebook Tweet about Vehicle Technologies Office: Vehicle Technologies Office Recognizes Outstanding Researchers on Twitter Bookmark Vehicle Technologies Office: Vehicle Technologies Office Recognizes Outstanding Researchers on Google Bookmark Vehicle Technologies Office: Vehicle Technologies Office Recognizes Outstanding Researchers on Delicious Rank Vehicle Technologies Office: Vehicle Technologies Office Recognizes Outstanding Researchers on Digg Find More places to share Vehicle Technologies Office: Vehicle Technologies Office Recognizes Outstanding Researchers on AddThis.com...

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

MODELING POWDERED SORBENT INJECTION IN COMBINATION WITHE FABRIC FILTER FOR THE CONTROL OF MERCURY EMISSIONS  

NLE Websites -- All DOE Office Websites (Extended Search)

POWDERED SORBENT INJECTION IN POWDERED SORBENT INJECTION IN COMBINATION WITH FABRIC FILTER FOR THE CONTROL OF MERCURY EMISSIONS Joseph R. V. Flora Department of Civil and Environmental Engineering University of South Carolina, Columbia, SC 29208 Richard A. Hargis, William J. O'Dowd, Henry W. Pennline National Energy Technology Laboratory, U.S. Department of Energy P.O. Box, 10940, Pittsburgh, PA 15236 Radisav D. Vidic * Department of Civil and Environmental Engineering University of Pittsburgh, Pittsburgh, PA 15261 ABSTRACT A two-stage mathematical model for mercury removal using powdered activated carbon injection upstream of a baghouse filter was developed, with the first stage accounting for removal in the ductwork and the second stage accounting for additional removal due to the

442

2011 NNSS Review of DAF-JCO Inoperable HEPA Filtered Vent. System  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

NNSS-2011-07-08 NNSS-2011-07-08 Site: Nevada National Security Site Subject: Office of Enforcement and Oversight's Office of Safety and Emergency Management Evaluations Activity Report for the Review of DAF-JCO-11-01 for Inoperable HEPA-Filtered Ventilation System Dates of Activity : 06/06/2011 - 07/08/2011 Report Preparer: William Macon Activity Description/Purpose: As an operational awareness activity, the Office of Health, Safety and Security (HSS) site lead reviewed a recent Justification for Continued Operations (JCO) for the Inoperable High Efficiency Particulate Air (HEPA)-Filtered Ventilation System at the Device Assembly Facility (DAF) at the Nevada National Security Site (NNSS). DAF- JCO-11-01, Revision 2, was prepared by the contractor, National Security Technologies, LLC (NSTec), on May

443

Contamination due to memory effects in filtered vacuum arc plasma deposition systems  

SciTech Connect

Thin film synthesis by filtered vacuum arc plasma deposition is a widely used technique with a number of important emerging technological applications. A characteristic feature of the method is that during the deposition process not only is the substrate coated by the plasma, but the plasma gun itself and the magnetic field coil and/or vacuum vessel section constituting the macroparticle filter are also coated to some extent. If then the plasma gun cathode is changed to a new element, there can be a contamination of the subsequent film deposition by sputtering from various parts of the system of the previous coating species. We have experimentally explored this effect and compared our results with theoretical estimates of sputtering from the SRIM (Stopping and Range of Ions in Matter) code. We find film contamination of order 10-4 - 10-3, and the memory of the prior history of the deposition hardware can be relatively long-lasting.

Martins, D.R.; Salvadori, M.C.; Verdonck, P.; Brown, I.G.

2002-08-13T23:59:59.000Z

444

Fail Save Shut Off Valve for Filtering Systems Employing Candle Filters  

DOE Patents (OSTI)

The invention relates to an apparatus that acts as a fail save shut off valve. More specifically, the invention relates to a fail save shut off valve that allows fluid flow during normal operational conditions, but prevents the flow of fluids in the event of system failure upstream that causes over-pressurization. The present invention is particularly well suited for use in conjunction with hot gas filtering systems, which utilize ceramic candle filters. Used in such a hot gas system the present invention stops the flow of hot gas and prevents any particulate laden gas from entering the clean side of the system.

VanOsdol, John

2006-01-03T23:59:59.000Z

445

FUEL CELL TECHNOLOGIES PROGRAM Technologies  

E-Print Network (OSTI)

.eere.energy.gov/informationcenter hydrogen and electricity for fuel cell and plug-in hybrid electric vehicles while using proven stationary vehicles with its own fuel cell technology. Currently, advanced vehicle technologies are being evalu- ated and fuel cells offer great promise for our energy future. Fuel cell vehicles are not yet commercially

446

Building Technologies Office: Emerging Technologies  

NLE Websites -- All DOE Office Websites (Extended Search)

Creating the Next Generation of Energy Efficient Technology Creating the Next Generation of Energy Efficient Technology The Emerging Technologies team partners with national laboratories, industry, and universities to advance research, development, and commercialization of energy efficient and cost effective building technologies. These partnerships help foster American ingenuity to develop cutting-edge technologies that have less than 5 years to market readiness, and contribute to the goal to reduce energy consumption by at least 50%. Sandia Cooler's innovative, compact design combines a fan and a finned metal heat sink into a single element, efficiently transferring heat in microelectronics and reducing energy use. Supporting Innovative Research to Help Reduce Energy Use and Advance Manufacturing Learn More

447

INEEL/EXT-97-  

NLE Websites -- All DOE Office Websites (Extended Search)

974 974 U.S. Department of Energy FreedomCAR & Vehicle Technologies Oil Bypass Filter Technology Evaluation Third Quarterly Report April-June 2003 Larry Zirker James Francfort August 2003 Idaho National Engineering and Environmental Laboratory Bechtel BWXT Idaho, LLC INEEL/EXT-03-00974 U.S. Department of Energy FreedomCAR & Vehicle Technologies Oil Bypass Filter Technology Evaluation Third Quarterly Report April-June 2003 Larry Zirker James Francfort August 2003 Idaho National Engineering and Environmental Laboratory Transportation Technology and Infrastructure Department Idaho Falls, Idaho 83415 Prepared for the U.S. Department of Energy Assistant Secretary for Energy Efficiency and Renewable Energy Under DOE Idaho Operations Office

448

Advanced Techniques for Removal of Retrievable Inferior Vena Cava Filters  

Science Conference Proceedings (OSTI)

Inferior vena cava (IVC) filters have proven valuable for the prevention of primary or recurrent pulmonary embolism in selected patients with or at high risk for venous thromboembolic disease. Their use has become commonplace, and the numbers implanted increase annually. During the last 3 years, in the United States, the percentage of annually placed optional filters, i.e., filters than can remain as permanent filters or potentially be retrieved, has consistently exceeded that of permanent filters. In parallel, the complications of long- or short-term filtration have become increasingly evident to physicians, regulatory agencies, and the public. Most filter removals are uneventful, with a high degree of success. When routine filter-retrieval techniques prove unsuccessful, progressively more advanced tools and skill sets must be used to enhance filter-retrieval success. These techniques should be used with caution to avoid damage to the filter or cava during IVC retrieval. This review describes the complex techniques for filter retrieval, including use of additional snares, guidewires, angioplasty balloons, and mechanical and thermal approaches as well as illustrates their specific application.

Iliescu, Bogdan; Haskal, Ziv J., E-mail: ziv2@mac.com [University of Maryland School of Medicine, Division of Vascular and Interventional Radiology (United States)

2012-08-15T23:59:59.000Z

449

N Reactor filter system fission-product retention assessment  

Science Conference Proceedings (OSTI)

Data for the N Reactor High-Efficiency Particulate Air (HEPA) filter and charcoal filter systems have been evaluated to determine appropriate filter efficiencies for elemental iodine, methyl iodide, hydrogen iodide, and particulates. The data supports the following filter efficiencies: particulates - 99.95%, elemental iodine - 99%, methyl iodide - 70%, and hydrogen iodide - 99%. The HEPA filter and charcoal filter system, loading capacities have been determined for both radionuclide and non-radioactive aerosols. The results demonstrated that the capacity of the N Reactor confinement filtration system is more than adequate to retain both radionuclide and non-radioactive aerosols postulated to be released during accident situations without overloading. In addition, potential filter failure due to unacceptable heat loads from collected radionuclides was evaluated. The results show that with an acceptable air flow through the filter system (greater than 850 ft/sup 3//min), the heat load on the filters from deposited radionuclides will not lead to filter failure. 30 refs., 8 figs., 13 tabs.

Muhlstein, L.D.; Jeppson, D.W.; McCormack, J.D.

1988-06-01T23:59:59.000Z

450

Qualifications of Candle Filters for Combined Cycle Combustion Applications  

Science Conference Proceedings (OSTI)

The direct firing of coal produces particulate matter that has to be removed for environmental and process reasons. In order to increase the current advanced coal combustion processes, under the U.S. Department of Energy's auspices, Siemens Westinghouse Power Corporation (SWPC) has developed ceramic candle filters that can operate at high temperatures. The Coal Research Center of Southern Illinois University (SIUC), in collaboration with SWPC, developed a program for long-term filter testing at the SIUC Steam Plant followed by experiments using a single-filter reactor unit. The objectives of this program funded by the U.S. Department of Energy were to identify and demonstrate the stability of porous candle filter elements for use in high temperature atmospheric fluidized-bed combustion (AFBC) process applications. These verifications were accomplished through extended time slipstream testing of a candle filter array under AFBC conditions using SIUC's existing AFBC boiler. Temperature, mass flow rate, and differential pressure across the filter array were monitored for a duration of 45 days. After test exposure at SIUC, the filter elements were characterized using Scanning Electron Microscopy and BET surface area analyses. In addition, a single-filter reactor was built and utilized to study long term filter operation, the permeability exhibited by a filter element before and after the slipstream test, and the thermal shock resilience of a used filter by observing differential pressure changes upon rapid heating and cooling of the filter. The data acquired during the slipstream test and the post-test evaluations demonstrated the suitability of filter elements in advanced power generation applications.

Tomasz Wiltowski

2008-08-31T23:59:59.000Z

451

Low pass filter for plasma discharge  

DOE Patents (OSTI)

An isolator is disposed between a plasma reactor and its electrical energy source in order to isolate the reactor from the electrical energy source. The isolator operates as a filter to attenuate the transmission of harmonics of a fundamental frequency of the electrical energy source generated by the reactor from interacting with the energy source. By preventing harmonic interaction with the energy source, plasma conditions can be readily reproduced independent of the electrical characteristics of the electrical energy source and/or its associated coupling network.

Miller, Paul A. (Albuquerque, NM)

1994-01-01T23:59:59.000Z

452

Technology Analysis  

NLE Websites -- All DOE Office Websites (Extended Search)

* Heavy Vehicle Technologies * Heavy Vehicle Technologies * Multi-Path Transportation Futures * Idling Studies * EDrive Vehicle Monthly Sales Transportation Research and Analysis Computing Center Working With Argonne Contact TTRDC Technology Analysis truck Heavy vehicle techologies are one subject of study. Research Reducing Greenhouse Gas Emissions from U.S. Transportation Heavy Vehicle Technologies Multi-Path Transportation Futures Study Idling Studies Light Duty Electric Drive Vehicles Monthly Sales Updates Lithium-Ion Battery Recycling and Life Cycle Analysis Reports Propane Vehicles: Status, Challenges, and Opportunities (pdf; 525 kB) Natural Gas Vehicles: Status, Barriers, and Opportunities (pdf; 696 kB) Regulatory Influences That Will Likely Affect Success of Plug-in Hybrid and Battery Electric Vehicles (pdf; 1.02 MB)

453

Fabrication Technology  

SciTech Connect

The mission of the Fabrication Technology thrust area is to have an adequate base of manufacturing technology, not necessarily resident at Lawrence Livermore National Laboratory (LLNL), to conduct the future business of LLNL. The specific goals continue to be to (1) develop an understanding of fundamental fabrication processes; (2) construct general purpose process models that will have wide applicability; (3) document findings and models in journals; (4) transfer technology to LLNL programs, industry, and colleagues; and (5) develop continuing relationships with the industrial and academic communities to advance the collective understanding of fabrication processes. The strategy to ensure success is changing. For technologies in which they are expert and which will continue to be of future importance to LLNL, they can often attract outside resources both to maintain their expertise by applying it to a specific problem and to help fund further development. A popular vehicle to fund such work is the Cooperative Research and Development Agreement with industry. For technologies needing development because of their future critical importance and in which they are not expert, they use internal funding sources. These latter are the topics of the thrust area. Three FY-92 funded projects are discussed in this section. Each project clearly moves the Fabrication Technology thrust area towards the goals outlined above. They have also continued their membership in the North Carolina State University Precision Engineering Center, a multidisciplinary research and graduate program established to provide the new technologies needed by high-technology institutions in the US. As members, they have access to and use of the results of their research projects, many of which parallel the precision engineering efforts at LLNL.

Blaedel, K.L.

1993-03-01T23:59:59.000Z

454

NETL: Control Technology: Advanced Hybrid Particulate Collector  

NLE Websites -- All DOE Office Websites (Extended Search)

Advanced Hybrid Particulate Collector Advanced Hybrid Particulate Collector Under DOE-NETL sponsorship, the University of North Dakota, Energy and Environmental Research Center (UND-EERC) has developed a new concept in particulate control, called an advanced hybrid particulate collector (AHPC). In addition to DOE and the EERC, the project team includes W.L. Gore & Associates, Inc., Allied Environmental Technologies, Inc., and the Otter Tail Power Company. The AHPC utilizes both electrostatic collection and filtration in a unique geometric configuration that achieves ultrahigh particle collection with much less collection area than conventional particulate control devices. The primary technologies for state-of-the-art particulate control are fabric filters (baghouses) and electrostatic precipitators (ESPs). A major limitation of ESPs is that the fractional penetration of 0.1- to 1.0-µm particles is typically at least an order of magnitude greater than for 10-µm particles, so a situation exists where the particles that are of greatest health concern are collected with the lowest efficiency. Fabric filters are currently considered to be the best available control technology for fine particles, but emissions are dependent on ash properties and typically increase if the air-to-cloth (A/C) ratio is increased. In addition, many fabrics cannot withstand the rigors of high-SO2 flue gases, which are typical for bituminous fuels. Fabric filters may also have problems with bag cleanability and high pressure drop, which has resulted in conservatively designed, large, costly baghouses.

455

Method of producing monolithic ceramic cross-flow filter  

DOE Patents (OSTI)

Ceramic filter of various configuration have been used to filter particulates from hot gases exhausted from coal-fired systems. Prior ceramic cross-flow filters have been favored over other types, but those previously horn have been assemblies of parts somehow fastened together and consequently subject often to distortion or delamination on exposure hot gas in normal use. The present new monolithic, seamless, cross-flow ceramic filters, being of one-piece construction, are not prone to such failure. Further, these new products are made by novel casting process which involves the key steps of demolding the ceramic filter green body so that none of the fragile inner walls of the filter is cracked or broken.

Larsen, David A. (Clifton Park, NY); Bacchi, David P. (Schenectady, NY); Connors, Timothy F. (Watervliet, NY); Collins, III, Edwin L. (Albany, NY)

1998-01-01T23:59:59.000Z

456

Method of producing monolithic ceramic cross-flow filter  

DOE Patents (OSTI)

Ceramic filter of various configuration have been used to filter particulates from hot gases exhausted from coal-fired systems. Prior ceramic cross-flow filters have been favored over other types, but those previously have been assemblies of parts somehow fastened together and consequently subject often to distortion or delamination on exposure hot gas in normal use. The present new monolithic, seamless, cross-flow ceramic filters, being of one-piece construction, are not prone to such failure. Further, these new products are made by a novel casting process which involves the key steps of demolding the ceramic filter green body so that none of the fragile inner walls of the filter is cracked or broken. 2 figs.

Larsen, D.A.; Bacchi, D.P.; Connors, T.F.; Collins, E.L. III

1998-02-10T23:59:59.000Z

457

Filter system cost comparison for IGCC and PFBC power systems  

SciTech Connect

A cost comparison was conducted between the filter systems for two advanced coal-based power plants. The results from this study are presented. The filter system is based on a Westinghouse advanced particulate filter concept, which is designed to operate with ceramic candle filters. The Foster Wheeler second-generation 453 MWe (net) pressurized fluidized-bed combustor (PFBC) and the KRW 458 MWe (net) integrated gasification combined cycle (IGCC) power plants are used for the comparison. The comparison presents the general differences of the two power plants and the process-related filtration conditions for PFBC and IGCC systems. The results present the conceptual designs for the PFBC and IGCC filter systems as well as a cost summary comparison. The cost summary comparison includes the total plant cost, the fixed operating and maintenance cost, the variable operating and maintenance cost, and the effect on the cost of electricity (COE) for the two filter systems.

Dennis, R.A.; McDaniel, H.M.; Buchanan, T. [and others

1995-12-01T23:59:59.000Z

458

Printed Circuit Board Metal Powder Filters for Low Electron Temperatures  

E-Print Network (OSTI)

We report the characterisation of printed circuit boards (PCB) metal powder filters and their influence on the effective electron temperature which is as low as 22 mK for a quantum dot in a silicon MOSFET structure in a dilution refrigerator. We investigate the attenuation behaviour (10 MHz- 20 GHz) of filter made of four metal powders with a grain size below 50 um. The room-temperature attenuation of a stainless steel powder filter is more than 80 dB at frequencies above 1.5 GHz. In all metal powder filters the attenuation increases with temperature. Compared to classical powder filters, the design presented here is much less laborious to fabricate and specifically the copper powder PCB-filters deliver an equal or even better performance than their classical counterparts.

Filipp Mueller; Raymond N. Schouten; Matthias Brauns; Tian Gang; Wee Han Lim; Nai Shyan Lai; Andrew S. Dzurak; Wilfred G. van der Wiel; Floris A. Zwanenburg

2013-04-11T23:59:59.000Z

459

MMTF: THE MARYLAND-MAGELLAN TUNABLE FILTER  

Science Conference Proceedings (OSTI)

This paper describes the Maryland-Magellan Tunable Filter (MMTF) on the Magellan-Baade 6.5 m telescope. MMTF is based on a 150 mm clear aperture Fabry-Perot (FP) etalon that operates in low orders and provides transmission bandpass and central wavelength adjustable from {approx}5 A to {approx}15 A and from {approx}5000 A to over {approx}9200 A, respectively. It is installed in the Inamori Magellan Areal Camera and Spectrograph and delivers an image quality of {approx}0.''5 over a field of view of 27' in diameter (monochromatic over {approx}10'). This versatile and easy-to-operate instrument has been used over the past three years for a wide variety of projects. This paper first reviews the basic principles of FP tunable filters, and then provides a detailed description of the hardware and software associated with MMTF and the techniques developed to observe with this instrument and reduce the data. The main lessons learned in the course of the commissioning and implementation of MMTF are highlighted next, before concluding with a brief outlook on the future of MMTF and of similar facilities which are soon coming on line.

Veilleux, S.; Weiner, B. J.; Rupke, D. S. N. [Department of Astronomy, University of Maryland, College Park, MD 20742 (United States)], E-mail: veilleux@astro.umd.edu, E-mail: bjw@as.arizona.edu, E-mail: drupke@ifa.hawaii.edu (and others)

2010-01-15T23:59:59.000Z

460

Investigation of Alternative Waste Forms for GTCC 14C Filters  

Science Conference Proceedings (OSTI)

This report demonstrates that both cement and vinyl ester-styrene (VES) are viable engineering solutions for the immobilization of Greater than Class C (GTCC) 14C filters. The number of power plants installing submicron-size cartridge filters has increased with the incentive of radiation dose reduction. However, utilities are experiencing difficulty disposing of these filters due to significant increases in 14C concentrations. By implementing the concentration averaging recommendations of this study, nuc...

2001-11-15T23:59:59.000Z

Note: This page contains sample records for the topic "bypass filter technologies" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Building Technologies Office: 2013 DOE Building Technologies...  

NLE Websites -- All DOE Office Websites (Extended Search)

2013 DOE Building Technologies Office Program Review to someone by E-mail Share Building Technologies Office: 2013 DOE Building Technologies Office Program Review on Facebook Tweet...

462

National Energy Technology Laboratory Technology Marketing ...  

National Energy Technology Laboratory Technology Marketing Summaries. Here you’ll find marketing summaries for technologies available for licensing from the ...

463

Gates/filters in Flow Cytometry Data Visualization  

E-Print Network (OSTI)

The flowViz package provides tools for visualization of flow cytometry data. This document describes the support for visualizing gates (a.k.a. filters). 1

unknown authors

2010-01-01T23:59:59.000Z

464

Gates/filters in Flow Cytometry Data Visualization  

E-Print Network (OSTI)

The flowViz package provides tools for visualization of flow cytometry data. This document describes the support for visualizing gates (a.k.a. filters). 1

unknown authors

2012-01-01T23:59:59.000Z

465

Integrated filters for the on-chip silicon photonics platform.  

E-Print Network (OSTI)

??We investigate the properties of integrated dielectric filters for the purposes of on-chip routing of photons. We started with the use of high quality factor… (more)

Frank, Ian Ward

2013-01-01T23:59:59.000Z

466

Compact cyclone filter train for radiological and hazardous environments  

DOE Patents (OSTI)

A compact cyclone filter train for the removal of hazardous and radiologi particles from a gaseous fluid medium which permits a small cyclone separator to be used in a very small space envelope due to the arrangement of the filter housing adjacent to the separator with the cyclone separator and the filters mounted on a plate. The entire unit will have a hoist connection at the center of gravity so that the entire unit including the separator, the filters, and the base can be lifted and repositioned as desired.

Bench, Thomas R. (Pittsburgh, PA)

1998-01-01T23:59:59.000Z

467

Performance analysis of Non Linear Filtering Algorithms for underwater images  

E-Print Network (OSTI)

Image filtering algorithms are applied on images to remove the different types of noise that are either present in the image during capturing or injected in to the image during transmission. Underwater images when captured usually have Gaussian noise, speckle noise and salt and pepper noise. In this work, five different image filtering algorithms are compared for the three different noise types. The performances of the filters are compared using the Peak Signal to Noise Ratio (PSNR) and Mean Square Error (MSE). The modified spatial median filter gives desirable results in terms of the above two parameters for the three different noise. Forty underwater images are taken for study.

Padmavathi, Dr G; Kumar, Mr M Muthu; Thakur, Suresh Kumar

2009-01-01T23:59:59.000Z

468

Ash reduction system using electrically heated particulate matter filter  

DOE Patents (OSTI)

A control system for reducing ash comprises a temperature estimator module that estimates a temperature of an electrically heated particulate matter (PM) filter. A temperature and position estimator module estimates a position and temperature of an oxidation wave within the electrically heated PM filter. An ash reduction control module adjusts at least one of exhaust flow, fuel and oxygen levels in the electrically heated PM filter to adjust a position of the oxidation wave within the electrically heated PM filter based on the oxidation wave temperature and position.

Gonze, Eugene V [Pinckney, MI; Paratore, Jr., Michael J; He, Yongsheng [Sterling Heights, MI

2011-08-16T23:59:59.000Z

469

A Training Program for Filter-Search Mine Detection Dogs  

E-Print Network (OSTI)

comparative Psychology A Training Program for Filter-Searchbehind and results of a training program designed to produceunderlying the training program were: (1) minimise

Fjellanger, R.; Andersen, E. K.; McLean, Ian. G.

2002-01-01T23:59:59.000Z

470

Cermet Materials, Self-Cleaning Cermet Filters, Apparatus and ...  

Another option permits an external heating element to be used to heat the cermet filter during use. ... Building Energy Efficiency; ... Solar Thermal; Startup America;

471

Parameters Impacting Crossflow Filter Performance of Hanford Tank ...  

Parameters Impacting Crossflow Filter Performance of Hanford Tank Waste Simulants Reid Peterson Justin Billings, Carolyn Burns, Richard Daniel, Phil Schonewill, Rick ...

472

Compact cyclone filter train for radiological and hazardous environments  

DOE Patents (OSTI)

A compact cyclone filter train is described for the removal of hazardous and radiological particles from a gaseous fluid medium which permits a small cyclone separator to be used in a very small space envelope due to the arrangement of the filter housing adjacent to the separator with the cyclone separators and the filters mounted on a plate. The entire unit will have a hoist connection at the center of gravity so that the entire unit including the separator, the filters, and the base can be lifted and repositioned as desired.

Bench, T.R.

1996-12-31T23:59:59.000Z

473

Biodiesel Effects on Diesel Particle Filter Performance: Milestone Report  

DOE Green Energy (OSTI)

Research results on the performance of biodiesel and biodiesel blends with ultra-low sulfur diesel (ULSD) and a diesel particle filter (DPF).

Williams, A.; McCormick, R. L.; Hayes, R.; Ireland, J.

2006-03-01T23:59:59.000Z

474

Effect of Biodiesel Blends on Diesel Particulate Filter Performance  

DOE Green Energy (OSTI)

Presents results of tests of ultra-low sulfur diesel blended with soy-biodiesel at 5 percent using a Cummins ISB engine with a diesel particulate filter.

Williams, A.; McCormick, R. L.; Hayes, R. R.; Ireland, J.; Fang, H. L.

2006-11-01T23:59:59.000Z

475

NREL: Geothermal Technologies - Projects  

NLE Websites -- All DOE Office Websites (Extended Search)

and Technology Technology Transfer Technology Deployment Energy Systems Integration Geothermal Technologies Search More Search Options Site Map Printable Version Projects The NREL...