Powered by Deep Web Technologies
Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Retrofit Program of a Euro 1 andn EUro 2 Urban Bus Fleet in La Rochelle:  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l LPROJECTS IN RENEWABLEOperated in Steady-State Achieved atRetrofitStatus

2

Metro/Transit Bus Pass Reimbursement Requirements The program is only available for CSUF faculty, staff, or students.  

E-Print Network [OSTI]

apply by the 15th of the month prior to the first month of reimbursement. Eligible non-permit holders receive 100% reimbursement of the Metro monthly pass cost (max $75). Eligible permit holders receive 25) 278-1382 FOR OFFICE USE ONLY Y/N Permit #: Initials: Date: Semester Parking Permit Approved Entered

de Lijser, Peter

3

Metro/Transit Pass Reimbursement Form Program Regulations  

E-Print Network [OSTI]

participate at least 70% of your scheduled workdays to meet program eligibility Eligible non-permit holders receive 100% reimbursement of the monthly Metro monthly pass cost (max $75) Eligible permit holders, WORK LOCATION, WORK HRS, PERMIT PURCHASE/TURNED IN) DAYS COMMUTED BY BUS REIMBURSEMENT REQUESTED (non-permit

de Lijser, Peter

4

Travel Reimbursement  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert Southwest RegionatSearchScheduled System BurstLongTitan Titan isTravel Reimbursement

5

Deep Energy Retrofits - Eleven California Case Studies  

E-Print Network [OSTI]

retrofit thermal leakage in guestroom ceiling…………………………….171retrofit thermal leakage in guestroom ceiling Figure 107 -

Less, Brennan

2014-01-01T23:59:59.000Z

6

Residential Retrofit Program Design Guide  

Broader source: Energy.gov [DOE]

This Residential Retrofit Program Design Guide focuses on the key elements and design characteristics of building and maintaining a successful residential retrofit program.

7

The Great Building Energy Predictor Shootout II: Measuring Retrofit Energy Savings  

E-Print Network [OSTI]

the MCC savings. Energy Systems Laboratory Texas A&M University Texas Engineering Experiment Station College Station, TX 77843-3581 ASHRAE Predictor Shootout H, p 4 BUS Savings Comparisons . ? In the BUS building, the savings were calculated using... Energy Systems Laboratory Texas A & M University Texas Engineering Experiment Station College Station, TX 77843-3581 ASHRAE Predictor Shootout II, p 6 Table 1: The Completed Entries received for the Predictor Shootout II: Measuring Retrofit Energy Savings...

Thamilseran, S.; Haberl, J. S.

1995-01-01T23:59:59.000Z

8

Residential Retrofit Program Design Guide Overview Transcript...  

Broader source: Energy.gov (indexed) [DOE]

Residential Retrofit Program Design Guide Overview Transcript.doc Residential Retrofit Program Design Guide Overview Transcript.doc Residential Retrofit Program Design Guide...

9

REIMBURSEMENT INSTRUCTIONS 1. You MUST register as a vendor with Clemson University before we  

E-Print Network [OSTI]

reimbursement form. 4. Reimbursements are partial reimbursements. In particular, car-pooling and sharing hotel

Mossinghoff, Michael

10

Retrofit Air Preheat Economics  

E-Print Network [OSTI]

Retrofit air preheat systems are the most reliable and efficient means to effect significant energy conservation for large existing industrial furnaces. Units can be quickly installed without a lengthy shutdown, and the furnace efficiency can...

Goolsbee, J. A.

1981-01-01T23:59:59.000Z

11

ADA Retrofit and Construction  

E-Print Network [OSTI]

ADA Retrofit and Construction Management Richfield, MN Breckenridge, MN #12;Introduction & Outline Design vs. Construction § Case Studies § City of Richfield's Transition Plan #12;How Detailed Should, MN #12;Case Study Breckenridge, MN #12;§ Construction Plans § Intersection Details for "tough

Minnesota, University of

12

Hydrogen powered bus  

ScienceCinema (OSTI)

Take a ride on a new type of bus, fueled by hydrogen. These hydrogen taxis are part of a Department of Energy-funded deployment of hydrogen powered vehicles and fueling infrastructure at nine federal facilities across the country to demonstrate this market-ready advanced technology. Produced and leased by Ford Motor Company , they consist of one 12- passenger bus and one nine-passenger bus. More information at: http://go.usa.gov/Tgr

None

2013-11-22T23:59:59.000Z

13

Bus transfer analysis  

SciTech Connect (OSTI)

This paper discusses bus transfer schemes and the methodology used in modeling and analysis. Due to the unavailability of generic acceptance criteria, simulations were performed to analyze the actual fast bus transfer operations at four operating nuclear power generating stations. Sample simulation results illustrating the transient variations in motors currents and torques are included. The analyses were performed to ensure that motors and other rotating parts are not subjected to excessive or accumulated stresses caused by bus transfer operations. A summary of the experience gained in the process of performing this work and suggested bus transfer acceptance criteria are also presented.

Weronick, R.; Hassan, I.D. [Raytheon Engineers and Constructors, Lyndhurst, NJ (United States)

1996-11-01T23:59:59.000Z

14

Passive retrofits for Navy housing  

SciTech Connect (OSTI)

A project to assess and initiate passive solar energy retrofits to US Navy family housing is described. The current data base for Navy housing (ECOP), and its enhancement for passive solar purposes options proposed for Navy housing are explained. The analysis goals and methods to evaluate the retrofits are discussed. An educational package to explain the retrofits is described.

Hibbert, R.; Miles, C.; Jones, R.; Peck, C.; Anderson, J.; Jacobson, V.; Dale, A.M.

1985-01-01T23:59:59.000Z

15

Multifamily Ventilation Retrofit Strategies  

SciTech Connect (OSTI)

In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

Ueno, K.; Lstiburek, J.; Bergey, D.

2012-12-01T23:59:59.000Z

16

HOLDSWORTH RETROFIT AND RENOVATION  

E-Print Network [OSTI]

IPCC report, the buildings sector has more potential to contribute to climate change mitigation thanHOLDSWORTH RETROFIT AND RENOVATION GREEN BUILDING COMMITTEE ENVIRONMENTAL PERFORMANCE ADVISORY Holdsworth Hall Shower and Bicycle Commuting 20 Behavioral Change /Green Office Program 22 ENERGY CONSUMPTION

Schweik, Charles M.

17

Compressed Air System Analysis and Retrofit for Energy Savings  

E-Print Network [OSTI]

several actions including piping retrofits, equipment upgrades, pressure control changes, and compressor retrofits....

Harding, C.; Nutter, D.

2014-01-01T23:59:59.000Z

18

Evaluation of Retrofit Delivery Packages  

SciTech Connect (OSTI)

Residential energy retrofit activities are a critical component of efforts to increase energy efficiency in the U.S. building stock; however, retrofits account for a small percentage of aggregate energy savings at relatively high per unit costs. This report by Building America research team, Alliance for Residential Building Innovation (ARBI), describes barriers to widespread retrofits and evaluates opportunities to improve delivery of home retrofit measures by identifying economies of scale in marketing, energy assessments, and bulk purchasing through pilot programs in portions of Sonoma, Los Angeles, and San Joaquin Counties, CA. These targeted communities show potential and have revealed key strategies for program design, as outlined in the report.

Berman, M.; Smith, P.; Porse, E.

2013-07-01T23:59:59.000Z

19

PSNH- Small Business Retrofit Program  

Broader source: Energy.gov [DOE]

Public Service of New Hampshire (PSNH), an electric utility, offers financial incentives and technical advice to small business customers seeking to improve energy efficiency through retrofits....

20

Quality Assurance for Residential Retrofit Programs | Department...  

Broader source: Energy.gov (indexed) [DOE]

Quality Assurance for Residential Retrofit Programs Quality Assurance for Residential Retrofit Programs Blue version of the EERE PowerPoint template, for use with PowerPoint 2007....

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Bus supervision deployment strategies for improved bus service reliability  

E-Print Network [OSTI]

Bus service reliability has always been a top concern for transit agencies and their customers. Unfortunately, there are several factors detrimental to reliable bus service. Outside influences such as weather, traffic, and ...

Pangilinan, Christopher Allan

2006-01-01T23:59:59.000Z

22

Bright prospects for lighting retrofits  

SciTech Connect (OSTI)

Great potential for energy savings can be found in the alleys, hallways and stairwells of multifamily buildings, but this potential is not always easy to realize. This article discusses the solution to common problems, retrofitting mistakes, retrofitting for savings, replacements for incandescent bulbs, better exit lights. 1 fig., 1 tab.

Hasterok, L. [Wisconsin Energy Conservation Corp., Madison, WI (United States)

1995-09-01T23:59:59.000Z

23

Process Energy Retrofits  

E-Print Network [OSTI]

shows up in a discharge of added heat to ambient and is spotted more quickly. (Not Replace) I~ - ......... c.... Doml..... By IneremanUl Coata Area Fortunately, there are snort CIrcUits past some of the other activation energy barriers...optimum Is the low point on the curve. The discontinuity or activation energy Is due to the coats.of weatherproofing, etc. Note that for this exlsti" Process Energy Retrofits Dan Steinmeyer Monsanto Co St. Louis, Mo U N C E R E T N...

Steinmeyer, D.

24

Strengthening Building Retrofit Markets  

SciTech Connect (OSTI)

The Business Energy Financing (BEF) program offered commercial businesses in Michigan affordable financing options and other incentives designed to support energy efficiency improvements. We worked through partnerships with Michigan utilities, lenders, building contractors, trade associations, and other community organizations to offer competitive interest rates and flexible financing terms to support energy efficiency projects that otherwise would not have happened. The BEF program targeted the retail food market, including restaurants, grocery stores, convenience stores, and wholesale food vendors, with the goal of achieving energy efficiency retrofits for 2 percent of the target market. We offered low interest rates, flexible payments, easy applications and approval processes, and access to other incentives and rebates. Through these efforts, we sought to help customers strive for energy savings retrofits that would save 20 percent or more on their energy use. This program helped Michigan businesses reduce costs by financing energy efficient lighting, heating and cooling systems, insulation, refrigeration, equipment upgrades, and more. Businesses completed the upgrades with the help of our authorized contractors, and, through our lending partners, we provided affordable financing options.

Templeton, Mary [Michigan Saves; Jackson, Robert [Michigan Energy Office

2014-04-15T23:59:59.000Z

25

Residential Retrofit Design Guide Overview | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Retrofit Design Guide Overview Residential Retrofit Design Guide Overview Residential Retrofit Design Guide Overview Webinar. Res Retro Design Guide Webinar 5-3-11...

26

TRAVEL REIMBURSEMENTS Basic Travel Guidelines  

E-Print Network [OSTI]

on supervised group trips or co-travelers sharing a room Private Car Mileage Shortest distance for travel Car Rentals You can rent up to an intermediate size car - additional insurance is not reimbursable for receipts, but may be submitted in addition to show proof of payment Car rental receipts showing payment

El Karoui, Noureddine

27

Advancing Residential Retrofits in Atlanta  

SciTech Connect (OSTI)

This report will summarize the home energy improvements performed in the Atlanta, GA area. In total, nine homes were retrofitted with eight of the homes having predicted source energy savings of approximately 30% or greater based on simulated energy consumption.

Jackson, Roderick K [ORNL; Kim, Eyu-Jin [Southface Energy Institute; Roberts, Sydney [Southface Energy Institute; Stephenson, Robert [Southface Energy Institute

2012-07-01T23:59:59.000Z

28

Fuel Cell Bus Takes a Starring Role in the BurbankBus Fleet,...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Bus Takes a Starring Role in the BurbankBus Fleet, Fuel Cell Technologies Program (FCTP) (Fact Sheet) Fuel Cell Bus Takes a Starring Role in the BurbankBus Fleet, Fuel Cell...

29

A Methodology for Identifying Retrofit Energy Savings in Commercial Buildings  

E-Print Network [OSTI]

Measured energy savings resulting from energy conservation retrofits in commercial buildings can be used to verify the success of the retrofits, determine the payment schedule for the retrofits, and guide the selection of future retrofits...

Kissock, K.; Reddy, A.; Claridge, D.

30

Deep Residential Retrofits in East Tennessee  

SciTech Connect (OSTI)

Executive Summary Oak Ridge National Laboratory (ORNL) is furthering residential energy retrofit research in the mixed-humid climate of East Tennessee by selecting 10 homes and guiding the homeowners in the energy retrofit process. The homeowners pay for the retrofits, and ORNL advises which retrofits to complete and collects post-retrofit data. This effort is in accordance with the Department of Energy s Building America program research goal of demonstrating market-ready energy retrofit packages that reduce home energy use by 30 50%. Through this research, ORNL researchers hope to understand why homeowners decide to partake in energy retrofits, the payback of home energy retrofits, and which retrofit packages most economically reduce energy use. Homeowner interviews help the researchers understand the homeowners experience. Information gathered during the interviews will aid in extending market penetration of home energy retrofits by helping researchers and the retrofit industry understand what drives homeowners in making positive decisions regarding these retrofits. This report summarizes the selection process, the pre-retrofit condition, the recommended retrofits, the actual cost of the retrofits (when available), and an estimated energy savings of the retrofit package using EnergyGauge . Of the 10 households selected to participate in the study, only five completed the recommended retrofits, three completed at least one but no more than three of the recommended retrofits, and two households did not complete any of the recommended retrofits. In the case of the two homes that did none of the recommended work, the pre-retrofit condition of the homes and the recommended retrofits are reported. The five homes that completed the recommended retrofits are monitored for energy consumption of the whole house, appliances, space conditioning equipment, water heater, and most of the other circuits with miscellaneous electric loads (MELs) and lighting. Thermal comfort is also monitored, with temperature and humidity measured in all conditioned zones, attics, crawlspaces, and unconditioned basements. In some homes, heat flux transducers are installed on the basement walls to help determine the insulating qualities of the technologies and practices. EnergyGauge is used to estimate the pre-retrofit and post-retrofit home energy rating system (HERS) index and reduction in energy consumption and energy bill. In a follow-up report, data from the installed sensors will be presented and analyzed as well as a comparison of the post-retrofit energy consumption of the home to the EnergyGauge model of the post-retrofit home. Table ES1 shows the retrofits that were completed at the eight households where some or all of the recommended retrofits were completed. Home aliases are used to keep the homeowners anonymous. Some key findings of this study thus far are listed as follows. Some homeowners (50%) are not willing to spend the money to reach 30 50% energy savings. Quality of retrofit work is significantly variable among contractors which impact the potential energy savings of the retrofit. Challenges exist in defining house volume and floor area. Of the five homes that completed all the recommended retrofits, energy bill savings was not the main driver for energy retrofits. In no case were the retrofits cost neutral given a 15 year loan at 7% interest for the retrofit costs.

Boudreaux, Philip R [ORNL; Hendrick, Timothy P [ORNL; Christian, Jeffrey E [ORNL; Jackson, Roderick K [ORNL

2012-04-01T23:59:59.000Z

31

Additional reimbursement details are available on the  

E-Print Network [OSTI]

with your participating employer. Once the above qualification criteria are met, reimbursement forms may of exercise equipment designed for cardiac and strength training. For example, most "traditional" health

Huang, Jianyu

32

Charlotte Green Supply Chain: Residential Retrofitting | Department...  

Broader source: Energy.gov (indexed) [DOE]

Charlotte Green Supply Chain: Residential Retrofitting Charlotte Green Supply Chain: Residential Retrofitting July 30, 2010 - 10:50am Addthis Joshua DeLung What does this mean for...

33

Building Retrofits for Increased Protection Against Airborne  

E-Print Network [OSTI]

Building Retrofits for Increased Protection Against Airborne Chemical and Biological Releases of Standards and Technology William A. Jeffrey, Director Building Retrofits for Increased Protection Against Dols Heather Davis Priya Lavappa Amy Rushing Building and Fire Research Laboratory Prepared for: U

34

Building America Webinar: Retrofitting Central Space Conditioning...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Control strategies to improve hydronic space heating performance Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings - Control...

35

Building America Webinar: Retrofitting Central Space Conditioning...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Introduction Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings - Introduction This presentation serves as the introduction to...

36

Strategy Guideline: Mitigation of Retrofit Risk Factors  

SciTech Connect (OSTI)

The Alliance for Residential Building Innovation (ARBI) is currently developing strategies designed to promote and achieve increased energy savings and promote upgrades in the residential retrofit sector. These strategies are targeted to retrofit program managers, retrofit contractors, policy makers, academic researchers, and non-governmental organizations. This report focuses on four key areas to promote home energy upgrades: fostering accurate energy savings projections; understanding consumer perceptions for energy savings; measuring energy savings, and ensuring quality control for retrofit installations.

Berman, M.; Smith, P.; Porse, E.

2012-12-01T23:59:59.000Z

37

Measuring retrofit savings in commercial buildings with pre-retrofit utility billing data and post-retrofit sub-metered data  

E-Print Network [OSTI]

Methodologies to measure energy and dollar savings resulting from energy conserving retrofits in commercial buildings when both pre-retrofit and post-retrofit monitored data are available at an hourly or daily level have already been developed...

Liu, Yue

1993-01-01T23:59:59.000Z

38

Available Alternative Fuel School Bus Products--2004  

SciTech Connect (OSTI)

This 4-page Clean Cities fact sheet provides a list of the currently available (and soon to be available) model year 2004 alternative fuel school bus and school bus engine products. It includes information from Blue Bird Corporation, Collins Bus Corporation, Corbeil Bus, Ford Motor Company, General Motors Corporation, Thomas Built Buses, Inc., Clean Air Partners, Cummins Westport, and Deere & Company.

Not Available

2004-04-01T23:59:59.000Z

39

Monitoring conservative retrofits in single family buildings  

SciTech Connect (OSTI)

This study has provided detailed before-and-after information on the ambient and comfort conditions in nine single family buildings, and on the energy consumption of those buildings, for one or more energy conservation retrofits. The data were recorded in such a manner that as well as being able to determine the savings from the retrofits and the influence these retrofits have on the comfort conditions of the residence, the effects of the retrofits on time-of-day usage are also determinable. The following are included in appendices: a table of participant's names, site addresses and retrofit; significant dates and appropriate comments; a day of data and an annotated data set; pre-retrofit and post-retrofit audit data sheets; and usage history.

Richardson, C.S.

1992-12-06T23:59:59.000Z

40

Retrofit Savings for Brazos County  

E-Print Network [OSTI]

This report presents the energy and dollar savings for the period May 2000 - April 2001 for 10 of the Brazos County facilities that have been retrofit. The electricity use saved was 555,170 kWh and the demand was 1062 kW, which is equivalent to a...

Baltazar-Cervantes, J. C.; Shao, X.; Claridge, D. E.

2001-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Sunnyvale Marine Climate Deep Retrofit  

SciTech Connect (OSTI)

The Alliance for Residential Building Innovation (ARBI) and Allen Gilliland of One Sky Homes collaborated on a marine climate retrofit project designed to meet both Passive House (PH) and Building America (BA) program standards. The scope included sealing, installing wall, roof and floor insulation (previously lacking), replacing windows, upgrading the heating and cooling system, and installing.

German, A.; Siddiqui, A.; Dakin, B.

2014-11-01T23:59:59.000Z

42

Financial Policy and Procedures for Reimbursable Work  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The directive establishes Department-wide financial policy and procedural guidance applicable to performing reimbursable work for other Federal agencies and with non-Federal Government entities, including foreign and commercial entities, State, and political subdivisions.

1988-08-15T23:59:59.000Z

43

EPA`s local governments reimbursement program  

SciTech Connect (OSTI)

Under the Superfund Amendments and Reauthorization Act (SARA), section 123 of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA), Congress enacted the Local Governments Reimbursement (LGR) Program. The program`s goal is to provide financial relief to local governments that conduct emergency measures in response to releases or threats of releases of hazardous substances, pollutants, or contaminants. The intent of this program is to supply reimbursements of up to $25,000 per incident to the most deserving applicants, specifically local governments, for responses that exceed funds normally available for temporary emergency measures. These monies provide greatly needed support when potentially responsible party (PRP) searches and other cost recovery efforts fail. The standards and the approach for this program are set forth in 40 CFR Part 310, and are consistent with the overall policies and goals of the Superfund program. The maximum amount allocated to the reimbursement program is equal to 0.1 percent of the total amount appropriated for the Superfund, or approximately $1.7 million per year. A major focus of this program is to make known the availability of these funds for reimbursement to local governments in need of financial assistance. This paper highlights the features of this program, illustrates the types of incidents that have been awarded reimbursement, and describes common mistakes to be avoided when applying for reimbursement.

Zeller, E.; Ferguson, J. [Environmental Protection Agency, Washington, DC (United States). Emergency Response Division; Catalano, J.; Lally, R. [Booz Allen and Hamilton, Bethesda, MD (United States)

1994-12-31T23:59:59.000Z

44

EPA`s Local Governments Reimbursement Program  

SciTech Connect (OSTI)

Under the Superfund Amendments and Reauthorization Act (SARA), section 123 of the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA), Congress enacted the Local Governments Reimbursement (LGR) Program. The program`s goal is to provide financial relief to local governments that conduct emergency measures in response to releases or threats of releases of hazardous substances, pollutants, or contaminants. The intent of this program is to supply reimbursements of up to $25,000 per incident to the most deserving applicants, specifically local governments, for responses that exceed funds normally available for temporary emergency measures. These monies provide greatly needed support when potentially responsible party (PRP) searches and other cost-recovery efforts fail. The standards and the approach for this program are set forth in 40 CFR Part 310, and are consistent with the overall policies and goals of the Superfund program. The maximum amount allocated to the reimbursement program is equal to 0.1 percent of the total amount appropriated for the Superfund, or approximately $1.7 million per year. A major focus of this program is to make known the availability of these funds for reimbursement to local governments in need of financial assistance. This paper highlights the features of this program, illustrates the types of incidents that have been awarded reimbursement, and describes common mistakes to be avoided when applying for reimbursement.

Zeller, E.; Ferguson, J. [Environmental Protection Agency, Washington, DC (United States). Emergency Response Division; Catalano, J.; Lally, R. [Booz Allen and Hamilton, McLean, VA (United States)

1995-12-31T23:59:59.000Z

45

Retrofit for Plastic Resin Driers  

E-Print Network [OSTI]

RETROFIT FOR PLASTIC RESIN DRIERS BABU JOSEPH PH.D. Supervising Engineer Southern California Edison Company, Irwindale, California GEORGE THURO Thuro, & Associates, Costa Mesa, California Plastic resins used in injection molding have... installation of dew point meters and a programmable controller to tailor the regeneration cycle to the required dew point temperature. Background It was estimated that there are about 450 plastic processors in the Southern California Edison service...

Joseph, B.; Thuro, G.

46

Building Energy Model Development for Retrofit Homes  

SciTech Connect (OSTI)

Based on previous research conducted by Pacific Northwest National Laboratory and Florida Solar Energy Center providing technical assistance to implement 22 deep energy retrofits across the nation, 6 homes were selected in Florida and Texas for detailed post-retrofit energy modeling to assess realized energy savings (Chandra et al, 2012). However, assessing realized savings can be difficult for some homes where pre-retrofit occupancy and energy performance are unknown. Initially, savings had been estimated using a HERS Index comparison for these homes. However, this does not account for confounding factors such as occupancy and weather. This research addresses a method to more reliably assess energy savings achieved in deep energy retrofits for which pre-retrofit utility bills or occupancy information in not available. A metered home, Riverdale, was selected as a test case for development of a modeling procedure to account occupancy and weather factors, potentially creating more accurate estimates of energy savings. This “true up” procedure was developed using Energy Gauge USA software and post-retrofit homeowner information and utility bills. The 12 step process adjusts the post-retrofit modeling results to correlate with post-retrofit utility bills and known occupancy information. The “trued” post retrofit model is then used to estimate pre-retrofit energy consumption by changing the building efficiency characteristics to reflect the pre-retrofit condition, but keeping all weather and occupancy-related factors the same. This creates a pre-retrofit model that is more comparable to the post-retrofit energy use profile and can improve energy savings estimates. For this test case, a home for which pre- and post- retrofit utility bills were available was selected for comparison and assessment of the accuracy of the “true up” procedure. Based on the current method, this procedure is quite time intensive. However, streamlined processing spreadsheets or incorporation into existing software tools would improve the efficiency of the process. Retrofit activity appears to be gaining market share, and this would be a potentially valuable capability with relevance to marketing, program management, and retrofit success metrics.

Chasar, David; McIlvaine, Janet; Blanchard, Jeremy; Widder, Sarah H.; Baechler, Michael C.

2012-09-30T23:59:59.000Z

47

SCR & DPF RETROFITS FOR MOBILE DIESEL ENGINES  

Broader source: Energy.gov (indexed) [DOE]

SCR & DPF RETROFITS FOR MOBILE DIESEL ENGINES Thierry Leprince & Phil Roberts Extengine Transport Systems, LLC 1370 South Acacia Avenue Fullerton, CA - 92831 www.extengine.com...

48

NIPSCO- Existing Facility Retrofit Rebate Program  

Broader source: Energy.gov [DOE]

Northern Indiana Public Service Corporation (NIPSCO) offers incentives to commercial, industrial, nonprofit, government, and institutional customers for replacing or retrofitting equipment or...

49

Retrofit Ventilation Strategies in Multifamily Buildings Webinar...  

Energy Savers [EERE]

Retrofit of Mass Masonry Wall Assemblies Building America Technlogy Solutions for New and Existing Homes: Interior Foundation Insulation Upgrade - Madison Residence (Fact Sheet)...

50

Homeowner Best Practices Guide for Residential Retrofits  

E-Print Network [OSTI]

retrofitting your homes heating, cooling and ventilationranch style homes getting insufficient heating or cooling.bridge. Adequately heating all of your home is equally

Walker, Iain S.

2011-01-01T23:59:59.000Z

51

OTEC- Commercial Lighting Retrofit Rebate Program  

Broader source: Energy.gov [DOE]

The Oregon Trail Electric Consumers Cooperative (OTEC) offers a commercial lighting retrofit program that provides rebates for commercial businesses that change existing lighting to more energy...

52

Building America Expert Meeting: Interior Insulation Retrofit...  

Broader source: Energy.gov (indexed) [DOE]

Building Science Corporation team held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011, at the Westford Regency Hotel in...

53

Emission Control Systems and Components for Retrofit and First...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Systems and Components for Retrofit and First-Fit Applications Emission Control Systems and Components for Retrofit and First-Fit Applications 2004 Diesel Engine Emissions...

54

Retrofit Diesel Emissions Control System Providing 50% NOxControl...  

Broader source: Energy.gov (indexed) [DOE]

Retrofit Diesel Emissions Control System Providing 50% NOxControl Retrofit Diesel Emissions Control System Providing 50% NOxControl 2005 Diesel Engine Emissions Reduction (DEER)...

55

Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate Filters Transportation Refrigeration Unit (TRU) Retrofit with HUSS Active Diesel Particulate...

56

BetterBuildings Financing Energy Efficiency Retrofits in the...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

BetterBuildings Financing Energy Efficiency Retrofits in the Commercial Sector - Part 1 BetterBuildings Financing Energy Efficiency Retrofits in the Commercial Sector - Part 1...

57

Advanced Critical Advanced Energy Retrofit Education and Training...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Critical Advanced Energy Retrofit Education and Training and Credentialing - 2014 BTO Peer Review Advanced Critical Advanced Energy Retrofit Education and Training and...

58

SciTech Connect: Sunnyvale Marine Climate Deep Retrofit  

Office of Scientific and Technical Information (OSTI)

AND UTILIZATION RESIDENTIAL; RESIDENTIAL BUILDINGS; ARBI; BUILDING AMERICA; MARINE CLIMATE; RETROFIT; PASSIVE HOUSE; HVAC; MONITORING; INDOOR AIR QUALITY; DEEP RETROFIT; Buildings...

59

Residential Building Audits and Retrofits | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Residential Building Audits and Retrofits Residential Building Audits and Retrofits Blue version of the EERE PowerPoint template, for use with PowerPoint 2007. Transcript...

60

Building America Expert Meeting Report: Interior Insulation Retrofit...  

Broader source: Energy.gov (indexed) [DOE]

Interior Insulation Retrofit of Mass Masonry Wall Assembliesessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce...

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

SUSTAINABLE TRANSPORT IMPROVING AREA BUS SERVICES  

E-Print Network [OSTI]

System Public Bus Transit (MBTA) Ridership Analysis Schedule Adherence and On-Time Performance Public Transit MBTA Commuter Rail MBTA Rail Transit MBTA Bus Service Shuttle Services MIT Shuttle Service/19/2009 12 MassachusettsInstituteofTechnology #12;Public Bus Service - MBTA 11/19/2009Massachusetts

Entekhabi, Dara

62

Vehicle Technologies and Bus Fleet Replacement Optimization  

E-Print Network [OSTI]

1 Vehicle Technologies and Bus Fleet Replacement Optimization: problem properties and sensitivity: R41 #12;2 Abstract This research presents a bus fleet replacement optimization model to analyze hybrid and conventional diesel vehicles, are studied. Key variables affecting optimal bus type

Bertini, Robert L.

63

Retrofit Energy Savings Estimation Model Reference Manual  

E-Print Network [OSTI]

Retrofit Energy Savings Estimation Model Reference Manual #12;#12;Retrofit Energy Savings commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does from the Department of Energy. Any conclusions or opinions expressed in this manual represent solely

64

Commuter Choice Program Rail/Vanpool Reimbursement Form  

E-Print Network [OSTI]

workdays to meet program eligibility. Eligible non-permit holders receive 100% reimbursement (max $120); eligible permit holders receive 25% reimbursement (max $30) You will receive your reimbursement check CHANGES FROM THE PRIOR MONTH (ADDRESS, WORK LOCATION, WORK HRS, PERMIT PURCHASE/TURNED IN) COST OF RAIL

de Lijser, Peter

65

Proven Performance of Seven Cold Climate Deep Retrofit Homes  

SciTech Connect (OSTI)

Seven test homes located in Massachusetts are examined within this report. The retrofit strategies of each home are presented along with a comparison of the pre- and post-retrofit airtightness achieved by the group. Pre- and post-retrofit utility bills were collected; energy models were used to estimate pre-retrofit energy use when bills were unavailable.

Osser, R.; Neuhauser, K.; Ueno, K.

2012-06-01T23:59:59.000Z

66

USER SATISFACTION WITH INNOVATIVE COOLING RETROFITS IN SACRAMENTO PUBLIC HOUSING  

E-Print Network [OSTI]

and a housing authority have been retrofitting their buildings with evaporative coolers, ground-source heatpumps

Diamond, Richard

67

Electrical system architecture having high voltage bus  

DOE Patents [OSTI]

An electrical system architecture is disclosed. The architecture has a power source configured to generate a first power, and a first bus configured to receive the first power from the power source. The architecture also has a converter configured to receive the first power from the first bus and convert the first power to a second power, wherein a voltage of the second power is greater than a voltage of the first power, and a second bus configured to receive the second power from the converter. The architecture further has a power storage device configured to receive the second power from the second bus and deliver the second power to the second bus, a propulsion motor configured to receive the second power from the second bus, and an accessory motor configured to receive the second power from the second bus.

Hoff, Brian Douglas (East Peoria, IL); Akasam, Sivaprasad (Peoria, IL)

2011-03-22T23:59:59.000Z

68

PinBus Interface Design  

SciTech Connect (OSTI)

On behalf of the U.S. Department of Energy, PNNL has explored and expanded upon a simple control interface that might have merit for the inexpensive communication of smart grid operational objectives (demand response, for example) to small electric end-use devices and appliances. The approach relies on bi-directional communication via the electrical voltage states of from one to eight shared interconnection pins. The name PinBus has been suggested and adopted for the proposed interface protocol. The protocol is defined through the presentation of state diagrams and the pins’ functional definitions. Both simulations and laboratory demonstrations are being conducted to demonstrate the elegance and power of the suggested approach. PinBus supports a very high degree of interoperability across its interfaces, allowing innumerable pairings of devices and communication protocols and supporting the practice of practically any smart grid use case.

Hammerstrom, Donald J.; Adgerson, Jewel D.; Sastry, Chellury; Pratt, Richard M.; Pratt, Robert G.

2009-12-30T23:59:59.000Z

69

Retrofitting CO{sub 2} capture  

SciTech Connect (OSTI)

Retrofitting existing fossil-fueled plants with the first available carbon dioxide capture technologies could play an important role in paving the way for development of lower-cost, reliable carbon capture and storage systems. EPRI research is helping utilities better understand the engineering challenges and economic consequences. Studies are being conducted on retrofitting five different plants with advanced amine PCC technologies. Other studies include: process optimization studies; valuing operating flexibility; CO{sub 2} capture for CTCC plants; and assessing the impact of climate policy on retrofitting investment.

Weisel, J.

2009-07-01T23:59:59.000Z

70

Retrofitting the Streetlights in Boise, Idaho  

ScienceCinema (OSTI)

Boise, Idaho is using an energy efficiency grant to retrofit hundreds of streetlights throughout the downtown area with energy-efficient LED bulbs, which will save money and improve safety and local quality of life.

Young, Clay; Oliver, LeAnn; Bieter, David; Johnson, Michael; Oldemeyer, Neal

2013-05-29T23:59:59.000Z

71

Retrofitting the Streetlights in Boise, Idaho  

Broader source: Energy.gov [DOE]

Boise, Idaho is using an energy efficiency grant to retrofit hundreds of streetlights throughout the downtown area with energy-efficient LED bulbs, which will save money and improve safety and...

72

Energy Efficient Retrofits and Green Building Practices  

E-Print Network [OSTI]

. Moreover, the increase in demand is also causing rise in pollution levels. Therefore, the subject of energy efficient retrofits and green building practices is becoming increasingly important. Based on the latest walkthrough energy audit it is proven...

Rahman, M.

2010-01-01T23:59:59.000Z

73

Application of Pinch Technology in Refinery Retrofits  

E-Print Network [OSTI]

APPLICATION OF PINCH TECHNOLOGY IN REFINERY RETROFITS W. R. L. Thomas, J. H. Siegell, T. Sideropoulos, J. L. Robertson, S. A. Papoulias Exxon Research and Engineering Company Florham Park, New Jersey ABSTRACT This paper reviews... the application of pinch technology in the identification of the most attractive retrofit prospects in typical refineries. In the first part of the paper, methodology is described to identify attractive inter-unit heat integration opportunities as well...

Thomas, W. R.; Siegell, J. H.; Sideropoulos, T.; Robertson, J. L.; Papoulias, S. A.

74

Making your Building Smarter : The Retrofit Challenge  

E-Print Network [OSTI]

Wireless Temp Sensors IBM Dublin Research Labs : Smart Buildings Living Lab Environment Background ? 2012 IBM Corporation IBM Dublin Research Labs Our Smart Building Retrofit Challenges Retrofit Challenges Summary 1. Smart Building Design 2... Comfortable environment ?Reduce Energy/Water usage environment ?Keep within Budget ?Biggest Challenge ?? Constantly competing (& changing) objectives within the design and build cycles What to include ? What is critical? Where to Invest ? 5 ? 2012...

Brady, N.

2012-01-01T23:59:59.000Z

75

Evaluation of passive solar retrofit options  

SciTech Connect (OSTI)

An evaluation framework has been developed which allows for the assessment of the role of passive solar retrofit in the nationwide reduction of conventional fuel use. Three types of analysis are proposed within this framework: the physical/technical capability of the present housing stock to incorporate passive solar retrofit; the economic feasibility of the application of retrofit designs; and the actual market potential or acceptance of these alternative retrofit options. Each type of analysis has specific data requirements and a series of evaluation procedures to help establish estimates of the potential for passive solar retrofit in the present housing stock. The data requirements with their respective sources and evaluation procedures for the first two types of analysis-physical/technical setting and economic feasibility, are examined. A distinction is drawn between community specific case studies and more generalized national assessments. Information derived from these three types of analysis, whether case specific or national in scope, can then be used in an evaluation of potential economic impacts. The establishment of regional economic benefits and costs werve as a measure of the merit or attractiveness of the implementation of a passive solar retrofit program.

Ben-David, S.; Kirchemen, C.; Martin, S.; Noll, S.; Roach, F.

1980-01-01T23:59:59.000Z

76

Technology Validation: Fuel Cell Bus Evaluations  

SciTech Connect (OSTI)

Presentation for the 2005 U.S. Department of Energy Hydrogen Program review showing status of U.S. and international fuel cell transit bus evaluations.

Eudy, L.

2005-05-01T23:59:59.000Z

77

Technology Validation: Fuel Cell Bus Evaluations (Presentation)  

SciTech Connect (OSTI)

This presentation by Leslie Eudy at the 2007 DOE Hydrogen Program Annual Merit Review Meeting provides information about NREL's fuel cell bus evaluations.

Eudy, L.

2007-05-18T23:59:59.000Z

78

Retrofit Program of a Euro 1 andn EUro 2 Urban Bus Fleet in La...  

Broader source: Energy.gov (indexed) [DOE]

High particulate matter filtration efficiency No secondary emissions like NO2, Furan, Dioxins, PAH The system proved to work perfectly well in all driving conditions during real...

79

Retrofit Program of a Euro 1 andn EUro 2 Urban Bus Fleet in La...  

Broader source: Energy.gov (indexed) [DOE]

2004 Diesel Engine Emissions Reduction (DEER) Conference Presentation: Rhodia Electronics and Catalysis 2004deerrocher.pdf More Documents & Publications Improvement and...

80

Post-Retrofit Residential Assessments  

SciTech Connect (OSTI)

This study examined a range of factors influencing energy consumption in households that had participated in residential energy-efficiency upgrades. The study was funded by a grant from the U.S. Department of Energy’s Pacific Northwest National Laboratory and was conducted by faculty and staff of Portland State University Center for Urban Studies and Department of Economics. This work was made possible through the assistance and support of the Energy Trust of Oregon (ETO), whose residential energy-efficiency programs provided the population from which the sample cases were drawn. All households in the study had participated in the ETO Home Performance with Energy Star (HPwES) program. A number of these had concurrently pursued measures through other ETO programs. Post-retrofit energy outcomes are rarely investigated on a house-by-house basis. Rather, aggregate changes are ordinarily the focus of program impact evaluations, with deviation from aggregate expectations chalked up to measurement error, the vagaries of weather and idiosyncrasies of occupants. However, understanding how homes perform post-retrofit on an individual basis can give important insights to increase energy savings at the participant and the programmatic level. Taking a more disaggregated approach, this study analyzed energy consumption data from before and after the retrofit activity and made comparisons with engineering estimates for the upgrades, to identify households that performed differently from what may have been expected based on the estimates. A statistical analysis using hierarchal linear models, which accounted for weather variations, was performed looking separately at gas and electrical use during the periods before and after upgrades took place. A more straightforward comparison of billing data for 12-month periods before and after the intervention was also performed, yielding the majority of the cases examined. The later approach allowed total energy use and costs to be assessed but did not account for weather variation. From this statistical analysis, 18 study participants were selected and interviewed. The participants completed an in-home interview covering a range of topics, including changes in occupancy and additional changes to the homes that may have affected energy use. The goal of the interviews was to identify factors that may have contributed to unusual energy performance. These factors were identified by their frequency of occurrence in outperforming or underperforming homes, or simply by identifying factors that had the largest impact on overall savings. The motivations and levels of satisfaction with the outcomes of the upgrades were covered in detail, as well as extensive discussions of behaviors pertaining to thermal control, lighting, water, and appliance use. Most of cases studied achieved substantial energy savings, although it was more common for the projected savings to be greater than the demonstrated savings. Two factors that played a very large role in savings variation were 1) changes in occupancy and 2) fenestration improvements outside of the incentive programs. Motivation for pursuing the upgrades (e.g., environmental sustainability vs. comfort or cost savings) did not seem to play any role in achieving savings. Participants generally were more concerned with maintaining aesthetics through lighting than comfort through heating or cooling. They also seemed more likely to turn the lights off when leaving a room than to turn the heat off when leaving the home.

Lancaster, Ross; lutzenhiser, Loren; Moezzi, Mithra; Widder, Sarah H.; Chandra, Subrato; Baechler, Michael C.

2012-04-30T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Interprocessor bus switching system for simultaneous communication in plural bus parallel processing system  

DOE Patents [OSTI]

A bus switching apparatus and method for multiple processor computer systems comprises a plurality of bus switches interconnected by branch buses. Each processor or other module of the system is connected to a spigot of a bus switch. Each bus switch also serves as part of a backplane of a modular crate hardware package. A processor initiates communication with another processor by identifying that other processor. The bus switch to which the initiating processor is connected identifies and secures, if possible, a path to that other processor, either directly or via one or more other bus switches which operate similarly. If a particular desired path through a given bus switch is not available to be used, an alternate path is considered, identified and secured. 11 figures.

Atac, R.; Fischler, M.S.; Husby, D.E.

1991-01-15T23:59:59.000Z

82

Interprocessor bus switching system for simultaneous communication in plural bus parallel processing system  

DOE Patents [OSTI]

A bus switching apparatus and method for multiple processor computer systems comprises a plurality of bus switches interconnected by branch buses. Each processor or other module of the system is connected to a spigot of a bus switch. Each bus switch also serves as part of a backplane of a modular crate hardware package. A processor initiates communication with another processor by identifying that other processor. The bus switch to which the initiating processor is connected identifies and secures, if possible, a path to that other processor, either directly or via one or more other bus switches which operate similarly. If a particular desired path through a given bus switch is not available to be used, an alternate path is considered, identified and secured.

Atac, Robert (Aurora, IL); Fischler, Mark S. (Warrenville, IL); Husby, Donald E. (DeKalb, IL)

1991-01-01T23:59:59.000Z

83

Reimbursable Work for the Department of Homeland Security  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order establishes DOE policies and procedures for the acceptance, performance, and administration of reimbursable work directly funded by the Department of Homeland Security.

2006-08-17T23:59:59.000Z

84

Connecticut Transit (CTTRANSIT) Fuel Cell Transit Bus: Third...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Connecticut Transit (CTTRANSIT) in Hartford for one prototype fuel cell bus and three new diesel buses operating from the same location. The prototype fuel cell bus was...

85

Alloy Foam Diesel Emissions Control School Bus Implementation...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Alloy Foam Diesel Emissions Control School Bus Implementation Alloy Foam Diesel Emissions Control School Bus Implementation Poster presentation from the 2007 Diesel...

86

Fuel Cell Transit Bus Coordination and Evaluation Plan California...  

Broader source: Energy.gov (indexed) [DOE]

Transit Bus Coordination and Evaluation Plan California Fuel Cell Transit Evaluation Team Fuel Cell Transit Bus Coordination and Evaluation Plan California Fuel Cell Transit...

87

Overview of Fuel Cell Electric Bus Development | Department of...  

Broader source: Energy.gov (indexed) [DOE]

Fuel Cell Electric Bus Development Overview of Fuel Cell Electric Bus Development Presentation slides from the Fuel Cell Technologies Office webinar ""Fuel Cell Buses"" held...

88

Texas Hydrogen Highway - Fuel Cell Hybrid Bus and Fueling Infrastructu...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Hydrogen Highway - Fuel Cell Hybrid Bus and Fueling Infrastructure Technology Showcase Texas Hydrogen Highway - Fuel Cell Hybrid Bus and Fueling Infrastructure Technology Showcase...

89

Concrete Masonry Wall Retrofit Systems for Blast Protection  

E-Print Network [OSTI]

. The experimental program used to evaluate the alternative retrofit systems was divided into three phases. In Phase one, resistance functions for seven different retrofit systems were developed in 24 subscale static experiments. In Phase two, the structural response...

Johnson, Carol Faye

2013-12-11T23:59:59.000Z

90

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network [OSTI]

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate...

Graham, E. L.

1980-01-01T23:59:59.000Z

91

DOE Webinar ? Residential Geothermal Heat Pump Retrofits (Presentation)  

Broader source: Energy.gov [DOE]

DOE webinar, Residential Geothermal Heat Pump Retrofits presented at the DOE EERE Webinar Series on Dec. 14, 2010.

92

Financing Energy Efficiency Retrofits in the Commercial Sector Webinar  

Broader source: Energy.gov [DOE]

Financing Energy Efficiency Retrofits in the Commercial Sector Webinar, from the U.S. Department of Energy's Better Buildings program.

93

NREL Job Task Analysis: Retrofit Installer Technician (Revised)  

SciTech Connect (OSTI)

A summary of job task analyses for the position of retrofit installer technician when conducting weatherization work on a residence.

Kurnik, C.; Woodley, C.

2012-04-01T23:59:59.000Z

94

Advanced Energy Retrofit Guide Retail Buildings  

SciTech Connect (OSTI)

The Advanced Energy Retrofit Guide for Retail Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

Liu, Guopeng; Liu, Bing; Zhang, Jian; Wang, Weimin; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

2011-09-19T23:59:59.000Z

95

Advanced Energy Retrofit Guide Office Buildings  

SciTech Connect (OSTI)

The Advanced Energy Retrofit Guide for Office Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

Liu, Guopeng; Liu, Bing; Wang, Weimin; Zhang, Jian; Athalye, Rahul A.; Moser, Dave; Crowe, Eliot; Bengtson, Nick; Effinger, Mark; Webster, Lia; Hatten, Mike

2011-09-27T23:59:59.000Z

96

Monitoring conservative retrofits in single family buildings. Final technical report  

SciTech Connect (OSTI)

This study has provided detailed before-and-after information on the ambient and comfort conditions in nine single family buildings, and on the energy consumption of those buildings, for one or more energy conservation retrofits. The data were recorded in such a manner that as well as being able to determine the savings from the retrofits and the influence these retrofits have on the comfort conditions of the residence, the effects of the retrofits on time-of-day usage are also determinable. The following are included in appendices: a table of participant`s names, site addresses and retrofit; significant dates and appropriate comments; a day of data and an annotated data set; pre-retrofit and post-retrofit audit data sheets; and usage history.

Richardson, C.S.

1992-12-06T23:59:59.000Z

97

Fuel Cell Bus Takes a Starring Role in the Burbank Bus Fleet  

Fuel Cell Technologies Publication and Product Library (EERE)

This fact sheet reports on the City of Burbank, California's fuel cell bus demonstration project and the U.S. Department of Energy's involvement.

98

National Grid Deep Energy Retrofit Pilot  

SciTech Connect (OSTI)

Through discussion of five case studies (test homes), this project evaluates strategies to elevate the performance of existing homes to a level commensurate with best-in-class implementation of high-performance new construction homes. The test homes featured in this research activity participated in Deep Energy Retrofit (DER) Pilot Program sponsored by the electric and gas utility National Grid in Massachusetts and Rhode Island. Building enclosure retrofit strategies are evaluated for impact on durability and indoor air quality in addition to energy performance. Evaluation of strategies is structured around the critical control functions of water, airflow, vapor flow, and thermal control. The aim of the research project is to develop guidance that could serve as a foundation for wider adoption of high performance, 'deep' retrofit work. The project will identify risk factors endemic to advanced retrofit in the context of the general building type, configuration and vintage encountered in the National Grid DER Pilot. Results for the test homes are based on observation and performance testing of recently completed projects. Additional observation would be needed to fully gauge long-term energy performance, durability, and occupant comfort.

Neuhauser, K.

2012-03-01T23:59:59.000Z

99

Evaluation of Crawlspace Retrofits in Multifamily Buildings  

SciTech Connect (OSTI)

In 2011 and early 2012, Building Science Corporation (BSC) collaborated with Innova Services Corporation on a multifamily community unvented crawlspace retrofit project at Oakwood Gardens in Lansdale, Pennsylvania. BSC provided design consulting services and pre- and post-retrofit evaluation, testing, and data monitoring. The existing condition was a vented crawlspace with an uninsulated floor between the crawlspace and the dwelling units above. The crawlspace was therefore a critically weak link in the building enclosure and was ripe for improvement. Saving energy was the primary interest and goal, but the greatest challenge in this unvented crawlspace retrofit project was working through a crawlspace bulk water intrusion problem caused by inadequate site drainage, window well drainage, foundation wall drainage, and a rising water table during rainy periods. While the unvented crawlspace retrofit was effective in reducing heat loss, and the majority of the bulk water drainage problems had been resolved, the important finding was that some of the wood joists embedded in masonry pockets behind the brick veneer were showing signs of moisture damage.

Rudd, A.

2014-09-01T23:59:59.000Z

100

Deep Energy Retrofits: A Southwestern Case Study  

E-Print Network [OSTI]

to a carbon-neutral environment, but we can remodel our way there. Over the course of seven years, green-buildingDeep Energy Retrofits: A Southwestern Case Study Heading Toward Net Zero Thursday, December 2, 2010 ASU Project Manager, Energize Phoenix Greg L. Brown Principal, Ecosense, LLC We cannot build our way

Zhang, Junshan

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

Greenbuilt Retrofit Test House Final Report  

SciTech Connect (OSTI)

The Greenbuilt house, is an all-electric, 1980's era home in the eastern Sacramento suburb of Fair Oaks that was retrofit by Greenbuilt Construction as part of Sacramento Municipal Utility District's (SMUD) Energy Efficient Remodel Demonstration (EERD) Program. The project was a joint effort between the design-build team at Greenbuilt Construction, led by Jim Bayless, SMUD and their project manager Mike Keesee, and the National Renewable Energy Laboratory (NREL). The goal of the Energy Efficient Remodel Demonstration program is to work with local builders to renovate homes with cost-effective energy efficient retrofit measures. The homes remodeled under the EERD program are intended to showcase energy efficient retrofit options for homeowners and other builders. The Greenbuilt house is one of five EERD projects that NREL has supported. NREL's main role in these projects is to provide energy analysis and to monitor the home's performance after the retrofit to verify that the energy consumption is in line with the modeling predictions. NREL also performed detailed monitoring on the more innovative equipment included in these remodels, such as an add-on heat pump water heater.

Sparn, B.; Hudon, K.; Earle, L.; Booten, C.; Tabares-Velasco, P. C.; Barker, G.; Hancock, C. E.

2014-06-01T23:59:59.000Z

102

Phillip Burton Federal Building EMCS Retrofit Analysis  

E-Print Network [OSTI]

and Renewable Energy, Office of Building Technology and Community Systems, and the Federal Energy ManagementPhillip Burton Federal Building EMCS Retrofit Analysis Interim Report March 1999 Rick Diamond, Tim This report presents the interim results of analyses carried out in the Phillip Burton Federal Building in San

Diamond, Richard

103

ARRA Proposed Award: Retrofit Bay Area  

E-Print Network [OSTI]

ARRA Proposed Award: Retrofit Bay Area Counties of Alameda, Contra Costa, Marin, San Francisco per year Prime contractor: Association of Bay Area Governments (ABAG) Sub contractors: Alameda County Waste Management Authority (StopWaste.org) County of Contra Costa County of Marin City

104

"We retrofitted mechanical systems in 8 buildings!"  

E-Print Network [OSTI]

"We retrofitted mechanical systems in 8 buildings!" LOW INTEREST RATE LOANS AVAILABLE NOW! County of Contra Costa California Energy Commission Apply Today! See Case Study on Back of Flyer "Our low interest and cooling systems in eight buildings. The energy efficient measures include replacing pneumatic controls

105

Retrofiting survivability of military vehicles  

SciTech Connect (OSTI)

In Iraq the terrain was such that vehicles could be distributed horizontally, which reduced the effectiveness of mines. In the mountainous terrain of Pakistan and Afghanistan vehicles are forced to use the few, passable roads, which are dirt and easily seeded with plentiful, cheap, intelligent mines. It is desirable to reduce the losses to such mines, preferably by retrofit means that do not greatly increase weight or cost or reduce maneuverability. V-bottom vehicles - A known approach to reducing vulnerability is the Buffalo, a large vehicle developed by South Africa to address mine warfare. It has large tires, high axles, and a reinforced, v-shaped bottom that deflects the blast from explosions below. It is developed and tested in combat, but is expensive and has reduced off-road mobility. The domestic MRAP has similar cost and mobility issue. The addition of v-shaped blast deflectors to vehicles such as Humvees could act much as the deflector on a Buffalo, but a Humvee is closer to the ground, so the explosive's expansion would be reduced. The deflector would also reduce a Humvee's clearance for rough terrain, and a deflector of adequate thickness to address the blast by itself could further increase cost and reduce mobility. Reactive armor is developed and has proven effective against shaped and explosive charges from side or top attack. It detects their approach, detonates, and defeats them by interfering with jet formation. If the threat was a shaped charge from below, they would be a logical choice. But the bulk of the damage to Humvees appears to be from the blast from high explosive mines for which the colliding shock from reactive armor could increase that from the explosive. Porous materials such as sand can strongly attenuate the kinetic energy and pressure of a strong shock. Figure 1 shows the kinetic energy (KE), momentum (Mu), velocity (u), and mass (M) of a spherically expanding shock as functions of radius for a material with a porosity of 0.5. Over the range from 0.5 to 4.5 cm the shock KE is attenuated by a factor of {approx}70, while its momentum is changed little. The shock and particle velocity falls by a factor of 200 while the mass increases by a factor of 730. In the limit of very porous media u {approx} 1/M, so KE {approx} 1/M, which falls by a factor of {approx}600, while momentum Mu does not change at all. Figure 2 shows the KE, Mu, u, and M for a material with a porosity of 1.05, for which the KE changes little. In the limit of media of very low porosity, u {approx} 1/{radical}M, so KE is constant while Mu {approx} {radical}M, which increases by a factor of 15. Thus, if the goal is to reduce the peak pressure from strong explosions below, very porous materials, which strongly reduce pressure but do not increase momentum, are preferred to non-porous materials, which amplify momentum but do not decrease pressure. These predictions are in qualitative accord with the results of experiments at Los Alamos in which projectiles from high velocity, large caliber cannons were stopped by one to two sandbags. The studies were performed primarily to determine the effectiveness of sand in stopping fragments of various sizes, but could be extended to study sand's effectiveness in attenuating blast pressure. It would also be useful to test the above predictions on the effectiveness of media with higher porosity. Water barriers have been discussed but not deployed in previous retrofit survivability studies for overseas embassies. They would detect the flash from the mine detonation below, trigger a thin layer of explosive above a layer of water, and drive water droplets into the approaching blast wave. The blast loses energy in evaporating the droplets and loses momentum in slowing them. Under favorable conditions that could attenuate the pressure in the blast enough to prevent the penetration or disruption of the vehicle. However, such barriers would depend on prompt and reliable detonation detection and water droplet dispersal, which have not been tested. There is a large literature on the theoretical effec

Canavan, Gregory H [Los Alamos National Laboratory

2009-01-01T23:59:59.000Z

106

BurbankBus' clean fuel fleet now includes a zero-emission hydrogen-fueled bus. BurbankBus, which provides transit  

E-Print Network [OSTI]

Bus fixed-route fleet consists of 17 compressed natural gas (CNG) buses. This fleet has been running on 100

107

Fuel Cell Hybrid Bus Lands at Hickam AFB: Hydrogen Fuel Cell...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Hybrid Bus Lands at Hickam AFB: Hydrogen Fuel Cell & Infrastructure Technologies Program, Fuel Cell Bus Demonstration Project (Fact Sheet) Fuel Cell Hybrid Bus Lands at Hickam AFB:...

108

SunLine Test Drives Hydrogen Bus: Hydrogen Fuel Cell & Infrastructure...  

Broader source: Energy.gov (indexed) [DOE]

SunLine Test Drives Hydrogen Bus: Hydrogen Fuel Cell & Infrastructure Technologies Program, Fuel Cell Bus Demonstration Projects Fact Sheet. SunLine Test Drives Hydrogen Bus:...

109

Cascade Apartments: Deep Energy Multifamily Retrofit  

SciTech Connect (OSTI)

In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions : 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit package after considering utility window incentives and KCHA capitol improvement funding.

Gordon, A.; Mattheis, L.; Kunkle, R.; Howard, L.; Lubliner, M.

2014-02-01T23:59:59.000Z

110

Retrofit California Overview and Final Reports  

SciTech Connect (OSTI)

Energy efficiency retrofits (also called upgrades) are widely recognized as a critical component to achieving energy savings in the building sector to help lower greenhouse gas (GHG) emissions. To date, however, upgrades have accounted for only a small percentage of aggregate energy savings in building stock, both in California and nationally. Although the measures and technologies to retrofit a building to become energy efficient are readily deployed, establishing this model as a standard practice remains elusive. Retrofit California sought to develop and test new program models to increase participation in the energy upgrade market in California. The Program encompassed 24 pilot projects, conducted between 2010 and mid-2013 and funded through a $30 million American Recovery and Reinvestment Act (ARRA) grant from the U.S. Department of Energy’s (DOE) Better Buildings Neighborhood Program (BBNP). The broad scope of the Program can be seen in the involvement of the following regionally based Grant Partners: Los Angeles County (as prime grantee); Association of Bay Area Governments (ABAG), consisting of: o StopWaste.org for Alameda County o Regional Climate Protection Authority (RCPA) for Sonoma County o SF Environment for the City and County of San Francisco o City of San Jose; California Center for Sustainable Energy (CCSE) for the San Diego region; Sacramento Municipal Utilities District (SMUD). Within these jurisdictions, nine different types of pilots were tested with the common goal of identifying, informing, and educating the people most likely to undertake energy upgrades (both homeowners and contractors), and to provide them with incentives and resources to facilitate the process. Despite its limited duration, Retrofit California undoubtedly succeeded in increasing awareness and education among home and property owners, as well as contractors, realtors, and community leaders. However, program results indicate that a longer timeframe will be needed to transform the market and establish energy retrofits as the new paradigm. Innovations such as Flex Path, which came about because of barriers encountered during the Program, have already shown promise and are enabling increased participation. Together, the pilots represent an unprecedented effort to identify and address market barriers to energy efficiency upgrades and to provide lessons learned to shape future program planning and implementation. The statistics reflects the scope of the marketing and outreach campaigns, which tested a variety of approaches to increase understanding of the benefits of energy upgrades to drive participation in the Program. More traditional methods such as TV and radio advertisements were complimented by innovative community based social marketing campaigns that sought to leverage the trusted status of neighborhood organizations and leaders in order to motivate their constituents to undertake retrofits. The remainder of this report provides an overview of Retrofit California including brief summaries of the pilots’ main components and highlights, followed by the major findings or takeaway lessons from the approaches that were tested. Eleven of the pilots will be continued, with modifications, under the ratepayer-funded Regional Energy Networks. Involvement in the RENS by many of the Retrofit California partners will ensure that early lessons learned are carried forward to guide future programs for energy upgrades in California.

Choy, Howard; Rosales, Ana

2014-03-01T23:59:59.000Z

111

HEART Reimbursement Act Form Mail completed form to  

E-Print Network [OSTI]

HEART Reimbursement Act Form Mail completed form to: Michigan State University MSU Human Resources Earnings Assistance and Relief (HEART) Act: If you are a member of a reserve component of the U.S. military

112

GL Report BU 355 CRSP CONSTRUCTION, TRUST, REIMBURSABLE  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

CONSTRUCTION, TRUST, REIMBURSABLE ( IN THOUSANDS) BUDGET FY 10 FY 11 FY 12 FY 13 FY 14 TOTAL ACTIVITY ACTUALS ACTUALS ACTUALS ACTUALS BUDGET OBS EXPEND OBS OCT NOV DEC JAN FEB MAR...

113

Retrofit Ventilation Strategies in Multifamily Buildings Webinar |  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energy fromComments onReplyofRetiring Procurement OfficialRetrofit

114

Retrofit Analysis of HVAC Systems Using Artificial Neural Networks.  

E-Print Network [OSTI]

??This thesis aims to explore the benefits of retrofits applied to the compressor and burner in the AC and furnace respectively and how best to… (more)

Anand, Anish

2014-01-01T23:59:59.000Z

115

Residential photovoltaic worth : an assessment of retrofit vs. new construction  

E-Print Network [OSTI]

This paper characterizes the basic differences between photovoltaic retrofit and new construction applications. It quantifies the tradeoffs forced by rooftop area constraints, special array mounting costs, maintenance ...

Dinwoodie, Thomas L.

1982-01-01T23:59:59.000Z

116

Retrofit Diesel Emissions Control System Providing 50% NOxControl  

Broader source: Energy.gov (indexed) [DOE]

LNT regeneration Minimal LNT volume Easy Retrofit Application: No modification to engine No engine control required Bolt-on design replaces existing muffler time Target: EPA...

117

Comparison of Home Retrofit Programs in Wisconsin  

SciTech Connect (OSTI)

To explore ways to reduce customer barriers and increase home retrofit completions, several different existing home retrofit models have been implemented in the state of Wisconsin. This study compared these programs' performance in terms of savings per home and program cost per home to assess the relative cost-effectiveness of each program design. However, given the many variations in these different programs, it is difficult to establish a fair comparison based on only a small number of metrics. Therefore, the overall purpose of the study is to document these programs' performance in a case study approach to look at general patterns of these metrics and other variables within the context of each program. This information can be used by energy efficiency program administrators and implementers to inform home retrofit program design. Six different program designs offered in Wisconsin for single-family energy efficiency improvements were included in the study. For each program, the research team provided information about the programs' approach and goals, characteristics, achievements and performance. The program models were then compared with performance results -- program cost and energy savings -- to help understand the overall strengths and weaknesses or challenges of each model.

Cunningham, K.; Hannigan, E.

2013-03-01T23:59:59.000Z

118

LOCAL BUS $178.00 LINK $267.00  

E-Print Network [OSTI]

- No refunds Pass Information: (617) 222-5218/6117 Schedule and Fare Information: (617) 222-3200 www.mbta, 2014 Local Bus $44.50/Month · Any local MBTA Bus or Trackless Trolley, excluding Mattapan High- Speed

Dennett, Daniel

119

A QUALITY CONTROL FRAMEWORK FOR BUS SCHEDULE RELIABILITY  

E-Print Network [OSTI]

A QUALITY CONTROL FRAMEWORK FOR BUS SCHEDULE RELIABILITY JIE LIN*, University of Illinois Institute A QUALITY CONTROL FRAMEWORK FOR BUS SCHEDULE RELIABILITY Abstract This paper develops and demonstrates a quality control framework for bus schedule reliability. Automatic Vehicle Location (AVL) devices

Illinois at Chicago, University of

120

Review of Prior Commercial Building Energy Efficiency Retrofit Evaluation: A Report to Snohomish Public Utilities District  

SciTech Connect (OSTI)

Snohomish County Public Utilities District (the District or Snohomish PUD) provides electricity to about 325,000 customers in Snohomish County, Washington. The District has an incentive programs to encourage commercial customers to improve energy efficiency: the District partially reimburses the cost of approved retrofits if they provide a level of energy performance improvement that is specified by contract. In 2013 the District contracted with Lawrence Berkeley National Laboratory to provide a third-party review of the Monitoring and Verification (M&V) practices the District uses to evaluate whether companies are meeting their contractual obligations. This work helps LBNL understand the challenges faced by real-world practitioners of M&V of energy savings, and builds on a body of related work such as Price et al. (2013). The District selected a typical project for which they had already performed an evaluation. The present report includes the District's original evaluation as well as LBNL's review of their approach. The review is based on the document itself; on investigation of the load data and outdoor air temperature data from the building evaluated in the document; and on phone discussions with Bill Harris of the Snohomish County Public Utilities District. We will call the building studied in the document the subject building, the original Snohomish PUD report will be referred to as the Evaluation, and this discussion by LBNL is called the Review.

Price, Phillip

2014-12-22T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Energy DataBus (Fact Sheet)  

SciTech Connect (OSTI)

NREL has developed the Energy DataBus, an open-sourced software that collects massive amounts of energy-related data at second-to-second intervals; stores it in a massive, scalable database; and turns it into useful information.

Not Available

2013-07-01T23:59:59.000Z

122

Joint Fuel Cell Bus Workshop Summary Report  

E-Print Network [OSTI]

Joint Fuel Cell Bus Workshop Summary Report Prepared for: U.S. Department of Energy (DOE/EERE) U was jointly sponsored by the Energy Efficiency and Renewable Energy office of the DOE and the Federal Transit the entire range of operating conditions and cycles · Cost (manufacturing, capital, operations

123

Ready to Retrofit: The Process of Project Team Selection, Building  

E-Print Network [OSTI]

, and Financing Commercial Building Energy Retrofit Projects Mark D. Sanders, Kristen Parrish, Paul Mathew for the Commercial Buildings Partnership (CBP) program, sponsored by the U.S. Department of Energy's Building a process for three key activities for the building owner in preparing to retrofit existing commercial

124

Nevada: Vegas Retrofits through Building America Enhance Home Performance  

Office of Energy Efficiency and Renewable Energy (EERE)

The EERE report Retrofitting Vegas: Implementing Energy Efficiency in Two Las Vegas Test Home notes that during the housing crisis, more than 11% of the existing housing stock in Las Vegas is in foreclosure (more than 8,100 homes). There is strong potential for achieving significant energy savings through retrofit activities in this region.

125

A Path to Successful Energy Retrofits: Early Collaboration through Integrated  

E-Print Network [OSTI]

and designers. It outlines the value of forming an integrated project delivery team and developing a complete process for designing an energy retrofit for a building. Instead, it focuses on the early design retrofits require integrated project delivery teams, this guide presents an integrated design process

126

GAO-04-148R Department of Energy: Reimbursement of Contractor...  

Broader source: Energy.gov (indexed) [DOE]

148R Department of Energy: Reimbursement of Contractor Litigation Costs GAO-04-148R Department of Energy: Reimbursement of Contractor Litigation Costs GAO-04-148R Department of...

127

Measure Guideline: Hybrid Foundation Insulation Retrofits  

SciTech Connect (OSTI)

This measure guideline provides recommendations for designs and variations for retrofit hybrid assemblies in improving interior foundation insulation and water management of basements. Variations include closed cell spray foam (ccSPF) with membrane waterproofing or air gap membrane drainage layers, rigid board foam insulation at flat walls (cast concrete or CMU block), a 'partial drainage' detail making use of the bulk water drainage that occurs through the field of a rubble stone wall, and non-drained spray foam assemblies (including slab insulation).

Ueno, K.; Lstiburek, J.

2012-05-01T23:59:59.000Z

128

Trial Demonstration of Area Lighting Retrofit  

Broader source: Energy.gov [DOE]

LED Area Lighting Retrofit: Yuma Border Patrol Along the Yuma Sector Border Patrol Area in Yuma, Arizona, the GATEWAY program conducted a trial demonstration in which the incumbent quartz metal halide area lighting was replaced with LED at three pole locations. The LED system was found to equal or better the incumbent system in terms of both illuminance and uniformity, and an advanced optical system and lower pole height improved the illuminance uniformity, reduced stray light, and increased projected energy and maintenance cost savings. This high luminous flux and high temperature application is not unique and similar applications can benefit from the findings of this installation.

129

Cost-effective Lighting Retrofits: Lessons Learned  

E-Print Network [OSTI]

maintained 44 61 96 37 58 % 34 57 % Mean maintained % = 59% The small office room depicted below aluminum full reflector was installed with the same contained one 2'x 4' lay-in deep cell parabolic T-8 lamps. Results are presented in the graph louver... accurate wattage values in calculating predicted savings from a lighting retrofit. Published ANSI values are not an accurate approximation of real world fixture wattage. Field testing within a 2' x 4' lay-in deep cell parabolic louver fixture produced...

Fisher, M. D.

1994-01-01T23:59:59.000Z

130

Retrofitting Doors on Open Refrigerated Cases  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l LPROJECTS IN RENEWABLEOperated in Steady-StateRetrofitting Doors on Open

131

Designing Effective Incentives to Drive Residential Retrofit Program Participation (Text Version)  

Broader source: Energy.gov [DOE]

Transcript of the webinar, "Designing Effective Incentives to Drive Residential Retrofit Program Participation."

132

Air Distribution Retrofit Strategies for Affordable Housing  

SciTech Connect (OSTI)

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, two retrofit duct sealing techniques -- manually-applied sealants and injecting a spray sealant, were implemented in several low-rise multi-unit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. It was found that 73% of the leakage reduction in homes that were treated with injected spray sealant was attributable to the manual sealing done at boots, returns and the air handler. The cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

Dentz, J.; Conlin, F.; Holloway, P.; Podorson, D.; Varshney, K.

2014-03-01T23:59:59.000Z

133

Retrofitting the Southeast: The Cool Energy House  

SciTech Connect (OSTI)

The Consortium for Advanced Residential Buildings has provided the technical engineering and building science support for a highly visible demonstration home in connection with the National Association of Home Builders' International Builders Show. The two previous projects, the Las Vegas net-zero ReVISION House and the 2011 VISION and ReVISION Houses in Orlando, met goals for energy efficiency, cost effectiveness, and information dissemination through multiple web-based venues. This project, which was unveiled at the 2012 International Builders Show in Orlando on February 9, is the deep energy retrofit Cool Energy House (CEH). The CEH began as a mid-1990s two-story traditional specification house of about 4,000 ft2 in the upscale Orlando suburb of Windermere.

Zoeller, W.; Shapiro, C.; Vijayakumar, G.; Puttagunta, S.

2013-02-01T23:59:59.000Z

134

DOE Webinar - Residential Geothermal Heat Pump Retrofits (Presentation)  

SciTech Connect (OSTI)

This presentation was given December 14, 2010, as part of DOE's Webinar series. The presentation discusses geothermal heat pump retrofits, technology options, and an overview of geothermal energy and geothermal heat pumps.

Anderson, E. R.

2010-12-14T23:59:59.000Z

135

Method for Determining Optimal Residential Energy Efficiency Retrofit Packages  

SciTech Connect (OSTI)

Businesses, government agencies, consumers, policy makers, and utilities currently have limited access to occupant-, building-, and location-specific recommendations for optimal energy retrofit packages, as defined by estimated costs and energy savings. This report describes an analysis method for determining optimal residential energy efficiency retrofit packages and, as an illustrative example, applies the analysis method to a 1960s-era home in eight U.S. cities covering a range of International Energy Conservation Code (IECC) climate regions. The method uses an optimization scheme that considers average energy use (determined from building energy simulations) and equivalent annual cost to recommend optimal retrofit packages specific to the building, occupants, and location. Energy savings and incremental costs are calculated relative to a minimum upgrade reference scenario, which accounts for efficiency upgrades that would occur in the absence of a retrofit because of equipment wear-out and replacement with current minimum standards.

Polly, B.; Gestwick, M.; Bianchi, M.; Anderson, R.; Horowitz, S.; Christensen, C.; Judkoff, R.

2011-04-01T23:59:59.000Z

136

EECBG Success Story: Lighting Retrofits Saving Energy, Helping...  

Broader source: Energy.gov (indexed) [DOE]

Pa. thousands in energy costs. | File photo It's easy to measure the effects of a lighting retrofit project in a city like Altoona, Pennsylvania, where 169 new LED units are...

137

A Methodology to Measure Retrofit Energy Savings in Commercial Buildings  

E-Print Network [OSTI]

. This dissertation develops a methodology to measure retrofit energy savings and the uncertainty of the savings in commercial buildings. The functional forms of empirical models of cooling and heating energy use in commercial buildings are derived from an engineering...

Kissock, John Kelly

2008-01-16T23:59:59.000Z

138

IRS Parking Facility Lighting Retrofit Reduces Annual Energy...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

in Kansas City, Missouri. The retrofit resulted in annual energy savings of 2 million kWh, annual cost savings of over 122,000, and a simple payback of 2.5 years....

139

Puget Sound Energy- Commercial Retrofit Energy Efficiency Grant Program  

Broader source: Energy.gov [DOE]

PSE can provide a custom retrofit grant for any energy-efficiency project that meets specified cost-effectiveness criteria and other PSE program requirements. To be eligible, customers must...

140

Street and Parking Facility Lighting Retrofit Financial Analysis Tool Webinar  

Broader source: Energy.gov [DOE]

DOE will present a live webinar titled "Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool" on Thursday, August 22, from 1:00 p.m. to 2:00 p.m. Eastern Daylight Time....

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

City of Los Angeles- Green Building Retrofit Requirement  

Broader source: Energy.gov [DOE]

In April 2009, Los Angeles enacted [clkrep.lacity.org/onlinedocs/2006/06-1963_ord_180633.pdf Ordinance 180636], known as the Green Building Retrofit Ordinance. This ordinance was later amended by...

142

Applications of sustainable technology to retrofits in urban areas  

E-Print Network [OSTI]

Energy Losses from old buildings comprise a significant percentage of the total residential energy consumption in the United States. Retrofitting buildings for conservation can greatly decrease the present energy demand ...

Taylor, Paki (Paki A.), 1974-

2001-01-01T23:59:59.000Z

143

DOE Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings  

Broader source: Energy.gov [DOE]

The Building America Program is hosting a no-cost, webinar-based training on Retrofitting Central Space Conditioning Strategies for Multifamily Buildings. The webinar will focus on improving the...

144

Tillamook County PUD- Dairy Lighting Retrofit Rebate Program  

Broader source: Energy.gov [DOE]

Tillamook PUD offers the Dairy Lighting Retrofit Program for its agricultural members to save energy on lighting in eligible barns/facilities. Tillamook PUD completes a lighting audit of the...

145

The retrofitting of existing buildings for seismic criteria  

E-Print Network [OSTI]

This thesis describes the process for retrofitting a building for seismic criteria. It explains the need for a new, performance-based design code to provide a range of acceptable building behavior. It then outlines the ...

Besing, Christa, 1978-

2004-01-01T23:59:59.000Z

146

Reimbursable Work for the Department of Homeland Security  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order establishes DOE policies and procedures for the acceptance, performance, and administration of reimbursable work directly funded by the Department of Homeland Security. Admin Chg 2, dated 6-30-14, cancels DOE O 484.1 Admin Chg 1.

2006-08-17T23:59:59.000Z

147

Reimbursable Work for the Department of Homeland Security  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

The Order establishes DOE policies and procedures for the acceptance, performance, and administration of reimbursable work directly funded by the Department of Homeland Security. Cancels DOE N 481.1 and DOE N 251.62. Admin Chg 1, dated 3-14-11.

2006-08-17T23:59:59.000Z

148

Web Reimbursement Create a Travel Authorization for BCD Travel  

E-Print Network [OSTI]

tickets purchased through BCD Travel directly to departmental General Ledger coding. Create TravelWeb Reimbursement Create a Travel Authorization for BCD Travel 7/19/2012 For Harvard Business Use Only Page 1 Create a Travel Authorization for BCD Travel HARVARD UNIVERSITY Create a Travel

Chen, Yiling

149

H&SS BUSINESS EXPENSE REIMBURSEMENT REQUEST INSTRUCTIONS  

E-Print Network [OSTI]

H&SS BUSINESS EXPENSE REIMBURSEMENT REQUEST INSTRUCTIONS 1. Complete all relevant information: ____________________________________________________________________________ CHARGE TO: _______________________________________________________ BUSINESS MEALS H&SS Policy Statement: Business meals should not exceed $75 per person, including tax and tip, for 2 5 guests. For groups > 5

Harrell, Mara

150

Retrofitting Doors on Open Refrigerated Cases | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energy fromComments onReplyofRetiring Procurement OfficialRetrofitRetrofitting

151

Connecticut Transit (CTTRANSIT) Fuel Cell Transit Bus: Second...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Second Evaluation Report and Appendices Connecticut Transit (CTTRANSIT) Fuel Cell Transit Bus: Second Evaluation Report and Appendices This report describes operations at...

152

Wyandotte Neighborhood Stabilization Program: Retrofit of Two Homes  

SciTech Connect (OSTI)

The Wyandotte NSP2 project aims to build 20 new houses and retrofit 20 existing houses in Wyandotte, MI. This report will detail the retrofit of 2 existing houses in the program. Wyandotte is part of a Michigan State Housing Development Authority-led consortium that is funded by HUD under the NSP2 program. The City of Wyandotte has also been awarded DOE EE&CBG funds that are being used to develop a district GSHP system to service the project. This draft report examines the energy efficiency recommendations for retrofit construction at these homes. The report will be of interest to anyone planning an affordable, high performance retrofit of an existing home in a Cold Climate zone. Information from this report will also be useful to retrofit or weatherization program staff as some of the proposed retrofit solutions will apply to a wide range of projects. Preliminary results from the first complete house suggest that the technology package employed (which includes spray foam insulation and insulating sheathing) does meet the specific whole house water, air, and thermal control requirements, as well as, the project's affordability goals. Monitoring of the GSHP system has been recommended and analysis of this information is not yet available.

Lukachko, A.; Grin, A.; Bergey, D.

2013-04-01T23:59:59.000Z

153

Retrofit of a Multifamily Mass Masonry Building in New England  

SciTech Connect (OSTI)

Merrimack Valley Habitat for Humanity (MVHfH) has partnered with Building Science Corporation to provide high performance affordable housing for 10 families in the retrofit of an existing brick building (a former convent) into condominiums. The research performed for this project provides information regarding advanced retrofit packages for multi-family masonry buildings in Cold climates. In particular, this project demonstrates safe, durable, and cost-effective solutions that will potentially benefit millions of multi-family brick buildings throughout the East Coast and Midwest (Cold climates). The retrofit packages provide insight on the opportunities for and constraints on retrofitting multifamily buildings with ambitious energy performance goals but a limited budget. The condominium conversion project will contribute to several areas of research on enclosures, space conditioning, and water heating. Enclosure items include insulation of mass masonry building on the interior, airtightness of these types of retrofits, multi-unit building compartmentalization, window selection, and roof insulation strategies. Mechanical system items include combined hydronic and space heating systems with hydronic distribution in small (low load) units, and ventilation system retrofits for multifamily buildings.

Ueno, K.; Kerrigan, P.; Wytrykowska, H.; Van Straaten, R.

2013-08-01T23:59:59.000Z

154

Page 264 Courses: Business Administration (BUS) Sonoma State University 2012-2013 Catalog Business Administration (BUS)  

E-Print Network [OSTI]

of consumer protection, antitrust, labor and employment law. BUS 230a financial accoUnting (4) A foundation, legal protection, insurance, investments, retirements, retirement planning, and estate planning emphasizes the sources, functions and processes of law. It surveys a number of areas, including negligence

Ravikumar, B.

155

Courses: Business Administration (BUS) Page 263Sonoma State University 2011-2012 Catalog Business Administration (BUS)  

E-Print Network [OSTI]

in the areas of consumer protection, antitrust, labor and employment law. buS 230A finAnCiAl ACCOuntinG (4, housing and other consumer decisions, legal protection, insurance, investments, retire- ments, retirement. The course emphasizes the sources, functions and processes of law. It surveys a number of areas, including

Ravikumar, B.

156

Shuttle Bus and Couriers | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehicles »ExchangeDepartmentResolve toSemiannual ReportsServicesShuttle Bus

157

DOE HQ Shuttle Bus Route and Schedule  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGYWomenthe HouseStudents2.2at Multipleorder supplies or Department2013U.S.Shuttle Bus

158

School Bus Emissions Study | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion | Department ofT ib l LPROJECTS IN7 RoadmapProgram| Department1 (Text Version)School Bus

159

Measurement of light capture in solar cells from silver- and tin-plated patterned bus bars  

E-Print Network [OSTI]

Bus bars on solar cells shade silicon from light. When the bus bars are patterned, they can reflect light back onto the silicon using total internal reflection. These patterned bus bars are tin plated and produce 1-2.5% ...

Winiarz, Christine Eve

2007-01-01T23:59:59.000Z

160

Pilot Residential Deep Energy Retrofits and the PNNL Lab Homes  

SciTech Connect (OSTI)

This report summarizes research investigating the technical and economic feasibility of several pilot deep energy retrofits, or retrofits that save 30% to 50% or more on a whole-house basis while increasing comfort, durability, combustion safety, and indoor air quality. The work is being conducted for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. As part of the overall program, Pacific Northwest National Laboratory (PNNL) researchers are collecting and analyzing a comprehensive dataset that describes pre- and post-retrofit energy consumption, retrofit measure cost, health and comfort impacts, and other pertinent information for each home participating in the study. The research and data collection protocol includes recruitment of candidate residences, a thorough test-in audit, home energy modeling, and generation of retrofit measure recommendations, implementation of the measures, test-out, and continued evaluation. On some homes, more detailed data will be collected to disaggregate energy-consumption information. This multi-year effort began in October 2010. To date, the PNNL team has performed test-in audits on 51 homes in the marine, cold, and hot-humid climate zones, and completed 3 retrofits in Texas, 10 in Florida, and 2 in the Pacific Northwest. Two of the retrofits are anticipated to save 50% or more in energy bills and the others - savings are in the 30% to 40% range. Fourteen other retrofits are under way in the three climate zones. Metering equipment has been installed in seven of these retrofits - three in Texas, three in Florida, and one in the Pacific Northwest. This report is an interim update, providing information on the research protocol and status of the PNNL deep energy retrofit project as of December, 2011. The report also presents key findings and lessons learned, based on the body of work to date. In addition, the report summarizes the status of the PNNL Lab Homes that are new manufactured homes procured with minimal energy-efficiency specifications typical of existing homes in the region, and sited on the PNNL campus. The Lab Homes serve as a flexible test facility (the first of its kind in the Pacific Northwest) to rapidly evaluate energy-efficient and grid-smart technologies that are applicable to residential construction.

Widder, Sarah H.; Chandra, Subrato; Parker, Graham B.; Sande, Susan; Blanchard, Jeremy; Stroer, Dennis; McIlvaine, Janet; Chasar, David; Beal, David; Sutherland, Karen

2012-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Modeling Transit Trip Time Using Archived Bus Dispatch System Data  

E-Print Network [OSTI]

Transportation District of Oregon TriMet provides transit service in the three-county Portland metropolitan area that are automatically collected and archived for each bus, route, and stop every day. The Tri-County Metropolitan. TriMet has implemented a Bus Dispatch System BDS as a part of its overall service control

Bertini, Robert L.

162

Connecticut Transit (CTTRANSIT) Fuel Cell Transit Bus: Preliminary Evaluation Results  

SciTech Connect (OSTI)

This report provides preliminary results from a National Renewable Energy Laboratory evaluation of a protoptye fuel cell transit bus operating at Connecticut Transit in Hartford. Included are descriptions of the planned fuel cell bus demonstration and equipment; early results and agency experience are also provided.

Chandler, K.; Eudy, L.

2008-10-01T23:59:59.000Z

163

SunLine Expands Horizons with Fuel Cell Bus Demo. Hydrogen, Fuel...  

Broader source: Energy.gov (indexed) [DOE]

Expands Horizons with Fuel Cell Bus Demo. Hydrogen, Fuel Cells & Infrastructure Technologies Program, Fuel Cell Bus Demonstration Projects (Fact Sheet). SunLine Expands Horizons...

164

A Model for the Bus System in Cuernevaca (Mexico)  

E-Print Network [OSTI]

The bus transportation system in Cuernevaca, Mexico, has certain distinguished, innovative features and has been the subject of an intriguing, recent study by M. Krbalek and P. Seba. Krbalek and Seba analyzed the statistics of bus arrivals on Line 4 close to the city center. They studied, in particular, the bus spacing distribution and also the bus number variance measuring the fluctuations of the total number of buses arriving at a fixed location during a time interval T. Quite remarkably, it was found that these two statistics are well modeled by the Gaussian Unitary Ensemble (GUE) of random matrix theory. Our goal in this paper is to provide a plausible explanation of these observations, and to this end we introduce a microscopic model for the bus line that leads simply and directly to GUE.

Jinho Baik; Alexei Borodin; Percy Deift; Toufic Suidan

2005-10-19T23:59:59.000Z

165

Effects of Catalysts on Emissions from Heavy-Duty Diesel Retrofits...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Catalysts on Emissions from Heavy-Duty Diesel Retrofits for PM and NOX Control Effects of Catalysts on Emissions from Heavy-Duty Diesel Retrofits for PM and NOX Control The more...

166

A Bin Method for Calculating Energy Conservation Retrofit Savings in Commercial Buildings  

E-Print Network [OSTI]

The calculation of measured energy savings from energy conservation retrofits is an important step in the verification of the success of a retrofit (Claridge et al. 1992). Several methods for calculating the savings from energy conservation...

Thamilseran, S.; Haberl, J. S.

1994-01-01T23:59:59.000Z

167

Research on Commercial Patterns of China Existing Building Energy Retrofit Based on Energy Management Contract  

E-Print Network [OSTI]

Existing building energy retrofit is one of the keys of building energy efficiency in China. According to experience in developed countries, implementation of energy management contract (EMC) is crucial to promote existing building energy retrofit...

Han, Z.; Liu, C.; Sun, J.

2006-01-01T23:59:59.000Z

168

Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst...  

Broader source: Energy.gov (indexed) [DOE]

Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst on a Tier 0, SD60M Freight Locomotive Achieving Over 50% PM Reduction Retrofit and Testing of a Pre-Turbo, Diesel...

169

ADEC II Universal SCR Retrofit System for On-road and Off-road...  

Broader source: Energy.gov (indexed) [DOE]

ADEC II Universal SCR Retrofit System for On-road and Off-road Diesel Engines ADEC II Universal SCR Retrofit System for On-road and Off-road Diesel Engines Presentation given at...

170

Using Archived AVL/APC Bus Data to Identify Spatial-Temporal1 Causes of Bus Bunching2  

E-Print Network [OSTI]

Using Archived AVL/APC Bus Data to Identify Spatial-Temporal1 Causes of Bus Bunching2 3 4 5 Wei passenger count (APC) technologies provide tremendous amounts of archived data for6 transit planners-year's worth of data for TriMet's Route 15. TriMet is the transit provider for the Portland,11 Oregon

Bertini, Robert L.

171

Short-Term Test Results: Multifamily Home Energy Efficiency Retrofit  

SciTech Connect (OSTI)

Multifamily deep energy retrofits (DERs) represent great potential for energy savings, while also providing valuable insights on research-generated efficiency measures, cost-effectiveness metrics, and risk factor strategies for the multifamily housing industry. The Bay Ridge project is comprised of a base scope retrofit with a goal of achieving 30% savings (relative to pre-retrofit), and a DER scope with a goal of 50% savings (relative to pre-retrofit). The base scope has been applied to the entire complex, except for one 12-unit building which underwent the DER scope. Findings from the implementation, commissioning, and short-term testing at Bay Ridge include air infiltration reductions of greater than 60% in the DER building; a hybrid heat pump system with a Savings to Investment Ratio (SIR) > 1 (relative to a high efficiency furnace) which also provides the resident with added incentive for energy savings; and duct leakage reductions of > 60% using an aerosolized duct sealing approach. Despite being a moderate rehab instead of a gut rehab, the Bay Ridge DER is currently projected to achieve energy savings ? 50% compared to pre-retrofit, and the short-term testing supports this estimate.

Lyons, J.

2013-01-01T23:59:59.000Z

172

Housing Stock Characterization Study: An Innovative Approach to Measuring Retrofit Impact  

SciTech Connect (OSTI)

A residential energy efficiency retrofit loan program depends on a self-sustaining finance option and optimized retrofit measures that recoup their unsubsidized costs through energy bill savings alone within the useful life of the retrofit. A first step in evaluating retrofit options is to measure and verify their energy savings. This report evaluates Orlando Utilities Commission (OUC) residential energy-efficiency demand side management (DSM) programs to assess their relative energy and economic performance.

Jones, P.; Taylor, N.; Kipp, J.

2012-09-01T23:59:59.000Z

173

Sustainable Energy Resources for Consumers Webinar on Residential Geothermal Heat Pump Retrofit Transcript  

Broader source: Energy.gov [DOE]

Transcript for a U.S. Department of Energy Webinar on Dec. 14, 2010, about residential geothermal heat pump retrofits

174

Bus bar electrical feedthrough for electrorefiner system  

DOE Patents [OSTI]

A bus bar electrical feedthrough for an electrorefiner system may include a retaining plate, electrical isolator, and/or contact block. The retaining plate may include a central opening. The electrical isolator may include a top portion, a base portion, and a slot extending through the top and base portions. The top portion of the electrical isolator may be configured to extend through the central opening of the retaining plate. The contact block may include an upper section, a lower section, and a ridge separating the upper and lower sections. The upper section of the contact block may be configured to extend through the slot of the electrical isolator and the central opening of the retaining plate. Accordingly, relatively high electrical currents may be transferred into a glovebox or hot-cell facility at a relatively low cost and higher amperage capacity without sacrificing atmosphere integrity.

Williamson, Mark; Wiedmeyer, Stanley G; Willit, James L; Barnes, Laurel A; Blaskovitz, Robert J

2013-12-03T23:59:59.000Z

175

Measure Guideline: Three High Performance Mineral Fiber Insulation Board Retrofit Solutions  

SciTech Connect (OSTI)

This Measure Guideline describes a high performance enclosure retrofit package that uses mineral fiber insulation board. The Measure Guideline describes retrofit assembly and details for wood frame roof and walls and for cast concrete foundations. This Measure Guideline is intended to serve contractors and designers seeking guidance for non-foam exterior insulation retrofit.

Neuhauser, K.

2015-01-01T23:59:59.000Z

176

Mini-Split Heat Pumps Multifamily Retrofit Feasibility Study  

SciTech Connect (OSTI)

Mini-split heat pumps can provide space heating and cooling in many climates and are relatively affordable. These and other features make them potentially suitable for retrofitting into multifamily buildings in cold climates to replace electric resistance heating or other outmoded heating systems. This report investigates the suitability of mini-split heat pumps for multifamily retrofits. Various technical and regulatory barriers are discussed and modeling was performed to compare long-term costs of substituting mini-splits for a variety of other heating and cooling options. A number of utility programs have retrofit mini-splits in both single family and multifamily residences. Two such multifamily programs are discussed in detail.

Dentz, J.; Podorson, D.; Varshney, K.

2014-05-01T23:59:59.000Z

177

Golden Valley Electric Association- Commercial Lighting Retrofit Rebate Program  

Broader source: Energy.gov [DOE]

BusBusiness $ense is a Golden Valley Electric Association (GVEA) program designed to increase the efficiency with which energy is used on GVEA's system. It provides rebates of up to $20,000 to...

178

Grupe Homes Enters the Whole-House Retrofit Market  

SciTech Connect (OSTI)

This article for HomeEnergy Magazine, a trade magazine on energy efficient home construction, retrofitting, remodeling, and research, describes retrofit projects by Grupe Homes of Sacramento, California, a production builder who has worked with DOE's Building America program on energy-efficient home demonstration projects. In this project, The article is a case study of Grupe's decision to enter the energy efficient remodeling market when new home sales lagged due to the economic slowdown starting in late 2007. The article also describes an energy-efficient retrofit of of a 22-year-old, 3-bedroom home in California’s Central Valley done in 2009 by Grupe. The home is Grupe's first retrofit and was done according to the criteria of Home Performance with ENERGY STAR, a national program from the EPA and DOE that promotes a comprehensive, whole-house approach to making energy-efficiency improvements. Grupe's staff were trained through the California Building Performance Contractors Association and passed the Building Performance Institute test to learn how to conduct extensive energy audits of existing houses as well to perform the energy efficient retrofits. In the retrofit home, they did extensive air sealing, replaced and added insulation, and replaced inefficient HVAC equipment and leaky can lights. They cut air leakage from 2478 to 1115 cfm 50, a 55% reduction. A Building America case study on this project was distributed at the EEBA (Energy and Environmental Building Alliance) Annual Conference in Denver, Colorado, Sept 28-30, 2009. The Home Energy article was published in the March/April 2010 issue.

Hefty, Marye G.; Gilbride, Theresa L.

2010-03-01T23:59:59.000Z

179

Modular industrial solar retrofit project (MISR)  

SciTech Connect (OSTI)

The intent of this paper is to describe a major Department of Energy (DOE) thrust to bring line-focus solar thermal technology to commercial readiness. This effort is referred to as the MISR Project. The project is based upon the premise that thermal energy is the basic solar thermal system output and that low-temperature, fossil fuel applications are technically the first that should be retrofitted. Experience has shown that modularity in system design and construction offers potential for reducing engineering design costs, reduces manufacturing costs, reduces installation time and expense, and improves system operational reliability. The modular design effort will be sponsored by Sandia National Laboratories with industry doing the final designs. The operational credibility of the systems will be established by allowing selected industrial thermal energy users to purchase MISR systems from suppliers and operate them for two years. Industries will be solicited by DOE/Albuquerque Operations Office to conduct these experiments on a cost sharing basis. The MISR system allowed in the experiments will have been previously qualified for the application. The project is divided into three development phases which represent three design and experiment cycles. The first cycle will use commercially available trough-type solar collectors and will incorporate 5 to 10 experiments of up to 5000 m/sup 2/ of collectors each. The project effort began in March 1980, and the first cycle is to be completed in 1985. Subsequent cycles will begin at 3-year intervals. The project is success oriented, and if the first cycle reaches commercial readiness, the project will be terminated. If not, a second, and possibly a third, development cycle will be conducted.

Alvis, R.L.

1980-01-01T23:59:59.000Z

180

Pilot Demonstration of Phased Retrofits in Florida Homes (Fact Sheet)  

SciTech Connect (OSTI)

The Florida Solar Energy Center (FSEC) and Florida Power and Light are pursuing a collaborative energy research/utility partnership to retrofit a large number of homes using a phased approach. The project is creating detailed data on the energy and economic performance of two levels of home retrofit - simple and deep. Acting as a pilot, this project is expected to provide the information necessary to significantly reduce energy use through much larger community-scale projects in collaboration with utilities, program administrators and other market leader stakeholders.

Not Available

2014-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Retrofit of Existing Residential Building: a Case Study  

E-Print Network [OSTI]

was reasonable, the construction quality was not good. The air leak from the circumference of window was serious and some inner surface of external walls formed condensation of moisture. Before retrofit, the annual heating energy consumption was 9.28?108kJ.... The annual coal consumption for heating was 31.68 tons standard coal. After retrofit, the annual heat consumption was 6.73?108kJ. The annual coal consumption for heating was 22.97 tons standard coal. With the 2.55?108kJ reduction of the annual heating...

Zhao, L.; Xu, W.; Li, L.; Gao, G.

2006-01-01T23:59:59.000Z

182

Measured Cooling Performance and Potential for Buried Duct Condensation in a 1991 Central Florida Retrofit Home  

SciTech Connect (OSTI)

FSEC conducted energy performance monitoring of two existing residences in Central Florida that were undergoing various retrofits. These homes were occupied by FSEC researchers and were fully instrumented to provide detailed energy, temperature, and humidity measurements. The data provided feedback about the performance of two levels of retrofit in two types of homes in a hot-humid climate. This report covers a moderate-level retrofit and includes two years of pre-retrofit data to characterize the impact of improvements. The other home is a 'deep energy retrofit' (detailed in a separate report) that has performed at near zero energy with a photovoltaic (PV) system and extensive envelope improvements.

Chasar, D.; Withers, C.

2013-02-01T23:59:59.000Z

183

Sustainable transport at MIT : improving area bus services  

E-Print Network [OSTI]

Everyday each member of the MIT community makes a decision about how they will travel to school or work. Using the Commuter Habit Survey and information regarding local bus services as guides, this report analyzes the ...

Beasley, Aimee K

2009-01-01T23:59:59.000Z

184

Spin-bus concept of spin quantum computing  

SciTech Connect (OSTI)

We present a spin-bus concept of quantum computing where an electron spin S=1/2 acts as a bus qubit connected to a finite number N of nuclear spins I=1/2 serving as client qubits. Spin-bus clusters are considered as local processing units and may be interconnected with other spin-bus clusters via electron-electron coupling in a scaled up version. Here we lay the ground for the basic functional unit with long qubit registers, provide the theory and experimental verification of correlated qubit states, and demonstrate the Deutsch algorithm. Experiments were performed on a qubyte plus one nuclear spin in a solid state system.

Mehring, Michael; Mende, Jens [2. Physikalisches Institut, University of Stuttgart (Germany)

2006-05-15T23:59:59.000Z

185

Copy 1 Purchasing Copy 2 Residence Hall Director Request for Reimbursement  

E-Print Network [OSTI]

copy to the Purchasing Office. 3. The Purchasing Director will review the "Request for RequestCopy 1 ­ Purchasing Copy 2 ­ Residence Hall Director MU 6/94 Request for Reimbursement For Damages: _________________________________________________________________________________________ _________________________________________________________________________________________ _________________________________________________________________________________________ #12;Copy 1 ­ Purchasing Copy 2 ­ Residence Hall Director PROCEDURES FOR REQUESTING REIMBURSEMENT

Hardy, Christopher R.

186

Solid state power bus controllers for aerospace applications  

E-Print Network [OSTI]

SOLID STATE POWER BUS CONTROLLERS FOR AEROSPACE APPLICATIONS A Thesis by TERRY JOSEPH VILLARREAL Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirement for the degree of MASTER... OF SCIENCE December 1988 Major Subject: Electrical Eny'neering SOLID STATE POWER BUS CONTROLLERS FOR AEROSPACE APPLICATIONS A Thesis TERRY JOSEPH VILLARREAL Approved as to style and content by: Mehrdad Ehsani (Chairman of Committee) Robert D. Nevels...

Villarreal, Terry Joseph

1988-01-01T23:59:59.000Z

187

Final Report for the H2Fuel Bus  

SciTech Connect (OSTI)

The H2Fuel Bus is the world's first hydrogen-fueled electric hybrid transit bus. It was a project developed through a public/private partnership involving several leading technological and industrial organizations, with primary funding by the Department of Energy (DOE). The primary goals of the project are to gain valuable information on the technical readiness and economic viability of hydrogen fueled buses and to enhance the public awareness and acceptance of emerging hydrogen technologies.

Jacobs, W.D.

1998-11-25T23:59:59.000Z

188

Energy and Indoor Environmental Quality Retrofits in Low-Income  

E-Print Network [OSTI]

Buildings are responsible for about 40 percent of the total U.S. energy demand and carbon dioxide environmental measurements and collect energy consumption data. Based on analyses of the data collected fromEnergy and Indoor Environmental Quality Retrofits in Low-Income Apartments ENVIRONMENTAL ENERGY

189

Expert Meeting Report: Retrofit Implementation - A Neighborhood at a Time  

SciTech Connect (OSTI)

This report provides information about a Building America expert meeting hosted by research team Consortium for Advanced Residential Buildings on October 25, 2011, in New York City. The meeting discussed several community residential retrofit projects underway across the United States, and included representatives from utilities, energy program implementation firms, affordable housing agencies, and the financing industry.

Griffiths, D.

2012-04-01T23:59:59.000Z

190

Retrofitting Existing Buildings for Demand Response & Energy Efficiency  

E-Print Network [OSTI]

partnership) · Plug loads, data centers ­ remainder (solution: WTR, WBM) Source: US Energy Information, higher "critical peak" energy charges will be assessed for usage between noon and 6pm. - CustomersRetrofitting Existing Buildings for Demand Response & Energy Efficiency www

California at Los Angeles, University of

191

Seismic Retrofitting of RC Frames with RC Infilling  

E-Print Network [OSTI]

Seismic Retrofitting of RC Frames with RC Infilling SERIES Workshop: "Role of research infrastructures in seismic rehabilitation" 8 - 9 February 2012, Istanbul, Turkey C. Z. Chrysostomou, N. Kyriakides, P. Kotronis, P. Roussis, M. Poljansek, F. Taucer RC Infilling of Existing RC Structures for Seismic

192

A Retrofit Tool for Improving Energy Efficiency of Commercial Buildings  

SciTech Connect (OSTI)

Existing buildings will dominate energy use in commercial buildings in the United States for three decades or longer and even in China for the about two decades. Retrofitting these buildings to improve energy efficiency and reduce energy use is thus critical to achieving the target of reducing energy use in the buildings sector. However there are few evaluation tools that can quickly identify and evaluate energy savings and cost effectiveness of energy conservation measures (ECMs) for retrofits, especially for buildings in China. This paper discusses methods used to develop such a tool and demonstrates an application of the tool for a retrofit analysis. The tool builds on a building performance database with pre-calculated energy consumption of ECMs for selected commercial prototype buildings using the EnergyPlus program. The tool allows users to evaluate individual ECMs or a package of ECMs. It covers building envelope, lighting and daylighting, HVAC, plug loads, service hot water, and renewable energy. The prototype building can be customized to represent an actual building with some limitations. Energy consumption from utility bills can be entered into the tool to compare and calibrate the energy use of the prototype building. The tool currently can evaluate energy savings and payback of ECMs for shopping malls in China. We have used the tool to assess energy and cost savings for retrofit of the prototype shopping mall in Shanghai. Future work on the tool will simplify its use and expand it to cover other commercial building types and other countries.

Levine, Mark; Feng, Wei; Ke, Jing; Hong, Tianzhen; Zhou, Nan

2013-06-06T23:59:59.000Z

193

An actuarial approach to retrofit savings in buildings  

SciTech Connect (OSTI)

An actuarial method has been developed for determining energy savings from retrofits from energy use data for a number of buildings. This method should be contrasted with the traditional method of using pre- and post-retrofit data on the same building. This method supports the U.S. Department of Energy Building Performance Database of real building performance data and related tools that enable engineering and financial practitioners to evaluate retrofits. The actuarial approach derives, from the database, probability density functions (PDFs) for energy savings from retrofits by creating peer groups for the user’s pre post buildings. From the energy use distribution of the two groups, the savings PDF is derived. This provides the basis for engineering analysis as well as financial risk analysis leading to investment decisions. Several technical issues are addressed: The savings PDF is obtained from the pre- and post-PDF through a convolution. Smoothing using kernel density estimation is applied to make the PDF more realistic. The low data density problem can be mitigated through a neighborhood methodology. Correlations between pre and post buildings are addressed to improve the savings PDF. Sample size effects are addressed through the Kolmogorov--Smirnov tests and quantile-quantile plots.

Subbarao, Krishnappa; Etingov, Pavel V.; Reddy, T. A.

2014-01-01T23:59:59.000Z

194

Building America Webinar: Who's Successfully Doing Deep Energy Retrofits?  

Broader source: Energy.gov [DOE]

The webinar on June 25, 2014, focused on specific Building America projects that highlighted real-world examples of deep energy retrofits (DER) that are meeting with technical and market success. Presenters focused on technical strategies, modeled and actual performance results, and project costs.

195

Building America Webinar: Who's Successfully Doing Deep Energy Retrofits?  

Broader source: Energy.gov [DOE]

The webinar will focus on specific Building America projects and case studies that highlight real-world examples of deep energy retrofits that are meeting with technical and market success. Presenters will focus on technical strategies, modeled and actual performance results, and project costs.

196

DIMETHYL ETHER (DME)-FUELED SHUTTLE BUS DEMONSTRATION PROJECT  

SciTech Connect (OSTI)

The objectives of this research and demonstration program are to convert a campus shuttle bus to operation on dimethyl ether, a potential ultra-clean alternative diesel fuel. To accomplish this objective, this project includes laboratory evaluation of a fuel conversion strategy, as well as, field demonstration of the DME-fueled shuttle bus. Since DME is a fuel with no lubricity (i.e., it does not possess the lubricating quality of diesel fuel), conventional fuel delivery and fuel injection systems are not compatible with dimethyl ether. Therefore, to operate a diesel engine on DME one must develop a fuel-tolerant injection system, or find a way to provide the necessary lubricity to the DME. In this project, they have chosen the latter strategy in order to achieve the objective with minimal need to modify the engine. Their strategy is to blend DME with diesel fuel, to obtain the necessary lubricity to protect the fuel injection system and to achieve low emissions. The bulk of the efforts over the past year were focused on the conversion of the campus shuttle bus. This process, started in August 2001, took until April 2002 to complete. The process culminated in an event to celebrate the launching of the shuttle bus on DME-diesel operation on April 19, 2002. The design of the system on the shuttle bus was patterned after the system developed in the engine laboratory, but also was subjected to a rigorous failure modes effects analysis (FMEA, referred to by Air Products as a ''HAZOP'' analysis) with help from Dr. James Hansel of Air Products. The result of this FMEA was the addition of layers of redundancy and over-pressure protection to the system on the shuttle bus. The system became operational in February 2002. Preliminary emissions tests and basic operation of the shuttle bus took place at the Pennsylvania Transportation Institute's test track facility near the University Park airport. After modification and optimization of the system on the bus, operation on the campus shuttle route began in early June 2002. However, the work and challenges continued as it has been difficult to maintain operability of the shuttle bus due to fuel and component difficulties. In late June 2002, the pump head itself developed operational problems (loss of smooth function) leading to excessive stress on the magnetic coupling and excessive current draw to operate. A new pump head was installed on the system to alleviate this problem and the shuttle bus operated successfully on DME blends from 10-25 vol% on the shuttle bus loop until September 30, 2002. During the period of operation on the campus loop, the bus was pulled from service, operated at the PTI test track and real-time emissions measurements were obtained using an on-board emissions analyzer from Clean Air Technologies International, Inc. Particulate emissions reductions of 60% and 80% were observed at DME blend ratios of 12 vol.% and 25 vol.%, respectively, as the bus was operated over the Orange County driving cycle. Increases in NOx, CO and HC emissions were observed, however. In summary, the conversion of the shuttle bus was successfully accomplished, particulate emissions reductions were observed, but there were operational challenges in the field. Nonetheless, they were able to demonstrate reliable operation of the shuttle bus on DME-diesel blends.

Elana M. Chapman; Shirish Bhide; Jennifer Stefanik; Howard Glunt; Andre L. Boehman; Allen Homan; David Klinikowski

2003-04-01T23:59:59.000Z

197

A Cost Benefit Analysis of a V2G-Capable Electric School Bus Compared to a Traditional Diesel School Bus  

E-Print Network [OSTI]

A Cost Benefit Analysis of a V2G-Capable Electric School Bus Compared to a Traditional Diesel analysis of a V2G-capable electric school bus compared to a traditional diesel school bus. Applied Energy (rmccorma@udel.edu) 1 Center for Carbon-Free Power Integration, University of Delaware ISE Lab, Newark, DE

Firestone, Jeremy

198

Using Archived AVL/APC Bus Data to Identify Spatial-Temporal Causes of Bus Bunching Wei Feng, Miguel A. Figliozzi  

E-Print Network [OSTI]

15 Using Archived AVL/APC Bus Data to Identify Spatial-Temporal Causes of Bus Bunching Wei Feng. The availability of tremendous amounts of archived data provides an opportunity to better understand the complex causes of bus bunching. This research is utilizes half year's data from automatic vehicle location (AVL

Bertini, Robert L.

199

Cascade Apartments - Deep Energy Multifamily Retrofit , Kent, Washington (Fact Sheet)  

SciTech Connect (OSTI)

In December of 2009-10, King County Housing Authority (KCHA) implemented energy retrofit improvements in the Cascade multifamily community, located in Kent, Washington (marine climate.)This research effort involved significant coordination from stakeholders KCHA, WA State Department of Commerce, utility Puget Sound Energy, and Cascade tenants. This report focuses on the following three primary BA research questions : 1. What are the modeled energy savings using DOE low income weatherization approved TREAT software? 2. How did the modeled energy savings compare with measured energy savings from aggregate utility billing analysis? 3. What is the Savings to Investment Ratio (SIR) of the retrofit package after considering utility window incentives and KCHA capitol improvement funding.

Not Available

2014-02-01T23:59:59.000Z

200

High-Efficiency Retrofit Lessons for Retail from a SuperTarget: Preprint  

SciTech Connect (OSTI)

The National Renewable Energy Laboratory partnered with Target under the Commercial Building Program to design and implement a retrofit of a SuperTarget in Thornton, CO. The result was a retrofit design that predicted 37% energy savings over ASHRAE Standard 90.1-2004, and 29% compared to existing (pre-retrofit) store consumption. The largest savings came from energy efficient lighting, energy efficient cooling systems, improved refrigeration, and better control of plug loads.

Langner, R.; Deru, M.; Hirsch, A.; Williams, S.

2013-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Chamberlain Heights Redevelopment: A Large Scale, Cold Climate Study of Affordable Housing Retrofits  

SciTech Connect (OSTI)

The City of Meriden Housing Authority (MHA) collaborated with affordable housing developer Jonathon Rose Companies (JRC) to complete a gut renovation of 124 residential units in the Chamberlain Heights retrofit project. The affordable housing community is made up of 36 buildings in duplex and quad configurations located on 22 acres within two miles of downtown Meriden, CT. The final post-retrofit analysis showed 40-45% source energy savings over the existing pre-retrofit conditions.

Donnelly, K.; Mahle, M.

2012-03-01T23:59:59.000Z

202

Next Step Toward Widespread Residential Deep Energy Retrofits  

SciTech Connect (OSTI)

The complexity of deep energy retrofits warrants additional training to successfully manage multiple improvements that will change whole house air, heat, and moisture flow dynamics. The home performance contracting industry has responded to these challenges by aggregating skilled labor for assessment of and implementation under one umbrella. Two emerging business models are profiled that seek to resolve many of the challenges, weaknesses, opportunities, and threats described for the conventional business models.

McIlvaine, J.; Saunders, S.; Bordelon, E.; Baden, S.; Elam, L.; Martin, E.

2013-07-01T23:59:59.000Z

203

Commissioning of the Fresno, California, Retrofit Unoccupied Test House  

SciTech Connect (OSTI)

Commissioning of instrumentation and limited short-term testing have been completed on a retrofit unoccupied test house in Fresno, California. This house is intended to be used as a laboratory in which several different methods of space conditioning distribution will be evaluated. This report provides background on the project, including specifications of the house and models used in its development, along with models to be evaluated through its operation.

Stecher, D.; Imm, C.

2013-06-01T23:59:59.000Z

204

Continuous Commissioning: A Valuable Partner to Retrofit Projects  

E-Print Network [OSTI]

-hand corner. Prior to commissioning, any changes in the duct static pressure or discharge air temperature setpoints did not affect the VFD speed. The operation of five AHUs was analyzed using the data collected through the EMCS. Table 2 presents summarized... variable frequency drives on constant speed motors and installing/modifying the DDC control system to control and optimize operation and to improve the system efficiency. In most cases, the retrofit projects realize their projected energy savings...

Turner, W. D.; Banks, K.; Athar, A.; Yazdani, B.; Zhu, Y.; Culp, C.

2001-01-01T23:59:59.000Z

205

Need for Systematic Retrofit Analysis in Multifamily Buildings  

SciTech Connect (OSTI)

Multifamily housing offers high potential for energy savings through retrofits. A comprehensive energy audit with systematic evaluation of alternative energy measures is one of the key steps to realizing the full energy savings potential. However, this potential often remains unrealized when the selection of measures is (1) based on a one-size-fits-all approach originating from accustomed practices, (2) intended merely to meet code-compliance requirements, and/or (3) influenced by owner renter split incentive. In such cases, the benefits of comprehensive energy auditing are disregarded in view of the apparent difficulty in diagnosing multifamily buildings, evaluating alternative measures, and installing customized sets of measures. This paper highlights some of the barriers encountered in a multifamily housing retrofit project in Georgia and demonstrates the merits of systematic retrofit analysis by identifying opportunities for higher energy savings and improved comfort and indoor air quality that were missed in this project. The study uses a whole-building energy analysis conducted for a 10-unit, low-rise, multifamily building of a 110-unit apartment complex. The analysis projected a 24% energy savings from the measures installed in the building with a payback period of 10 years. Further analysis with a systematic evaluation of alternative measures showed that without compromising on the objectives of durability, livability, and appearance of the building, energy savings of up to 34% were achievable with a payback period of 7 years. The paper concludes by outlining recommendations that may benefit future retrofit projects by improving the audit process, streamlining tasks, and achieving higher energy savings.

Malhotra, Mini [ORNL; Im, Piljae [ORNL

2014-01-01T23:59:59.000Z

206

Energy Efficient Crawlspace Foundation Retrofit: Mixed Humid Climate  

SciTech Connect (OSTI)

Residential quality management systems have most often been designed for new home construction. To address quality in existing homes in the form of Scopes of Work (SOW), the NAHB Research Center began with a new construction scope of work and applied it to an existing home project. This document is intended to outline the steps of translating a new home construction SOW to SOW for retrofit.

Del Bianco, M.; Wiehagen, J.; Wood, A.

2013-01-01T23:59:59.000Z

207

Retrofit Program Lead-by-Example Resources | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energy fromComments onReplyofRetiring Procurement OfficialRetrofit Program

208

Passive solar retrofit: an investment for the future  

SciTech Connect (OSTI)

America has a large inventory of older buildings which are directly contributing to the energy crunch. These liabilities could be converted to assets with the proper application of conservation and solar techniques. Through the use of one typical example, the economic and social benefits of such a conversion are discussed. A somewhat unusual method of financing is described, and a set of economic criteria often overlooked in the evaluation of a solar retrofit potential is addressed.

Balcomb, S.A.

1980-01-01T23:59:59.000Z

209

Short-Term Test Results: Transitional Housing Energy Efficiency Retrofit in the Hot-Humid Climate  

SciTech Connect (OSTI)

This project evaluates the renovation of a 5,800 ft2, multi-use facility located in St. Petersburg, on the west coast of central Florida, in the hot humid climate. An optimal package of retrofit measures was designed to deliver 30-40% annual energy cost savings for this building with annual utility bills exceeding $16,000 and high base load consumption. Researchers projected energy cost savings for potential retrofit measures based on pre-retrofit findings and disaggregated, weather normalized utility bills as a basis for simulation true-up. A cost-benefit analysis was conducted for the seven retrofit measures implemented; adding attic insulation and sealing soffits, tinting windows, improving whole building air-tightness, upgrading heating and cooling systems and retrofitting the air distribution system, replacing water heating systems, retrofitting lighting, and replacing laundry equipment. The projected energy cost savings for the full retrofit package based on a post-retrofit audit is 35%. The building's architectural characteristics, vintage, and residential and commercial uses presented challenges for both economic projections and retrofit measure construction.

Sutherland, K.; Martin, E.

2013-02-01T23:59:59.000Z

210

SciTech Connect: Analysis of Pre-Retrofit Building and Utility...  

Office of Scientific and Technical Information (OSTI)

and Utility Data IBACOS analyzed pre-retrofit daily utility data to sort homes by energy consumption, allowing for better targeting of homes for physical audits. Following...

211

Performance of a Hot-Dry Climate Whole-House Retrofit  

SciTech Connect (OSTI)

The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

Weitzel, E.; German, A.; Porse, E.

2014-06-01T23:59:59.000Z

212

Hungary-Employment Impacts of a Large-Scale Deep Building Retrofit...  

Open Energy Info (EERE)

Deep Building Retrofit Programme AgencyCompany Organization European Climate Foundation Sector Energy Focus Area Energy Efficiency, Buildings, - Building Energy Efficiency...

213

Protocol for Maximizing Energy Savings and Indoor Environmental Quality Improvements when Retrofitting Apartments  

SciTech Connect (OSTI)

The current focus on building energy retrofit provides an opportunity to simultaneously improve indoor environmental quality (IEQ). Toward this end, we developed a protocol for selecting packages of retrofits that both save energy and improve IEQ in apartments. The protocol specifies the methodology for selecting retrofits from a candidate list while addressing expected energy savings, IEQ impacts, and costs in an integrated manner. Interviews, inspections and measurements are specified to collect the needed input information. The protocol was applied to 17 apartments in three buildings in two different climates within California. Diagnostic measurements and surveys conducted before and after retrofit implementation indicate enhanced apartment performance.

Noris, Federico; Delp, William W.; Vermeer, Kimberly; Adamkiewicz, Gary; Singer, Brett C.; Fisk, William J.

2012-06-18T23:59:59.000Z

214

Calculating Energy and Demand Retrofit Savings for Stroman High School: Interim Report  

E-Print Network [OSTI]

As part of the LoanSTAR program, Stroman High School in Victoria Texas underwent two retrofits: a) an absorption chiller was changed to an electric vapor compression chiller, and b) an EMCS system was installed after about 5 months in the post retrofit... the pre-retrofit climate conditions. Both approaches are applied to the LoanSTAR site Stroman High School (SHS) in Victoria, Texas, in which (1) pre-retrofit data were not available , and (2) an absorption chiller was replaced by a vapor compression...

Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E.

1992-01-01T23:59:59.000Z

215

Text-Alternative Version: Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool  

Broader source: Energy.gov [DOE]

Below is the text-alternative version of the "Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool" webcast, held August 22, 2013.

216

Case study field evaluation of a systems approach to retrofitting a residential HVAC system  

E-Print Network [OSTI]

Practices for Residential HVAC Systems”. Boston, MA. Jump,techniques for measuring HVAC grille air flows". ASHRAEPractices Guide for Residential HVAC Retrofits. LBNL 53592.

Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

2003-01-01T23:59:59.000Z

217

Text-Alternative Version of Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings  

Broader source: Energy.gov [DOE]

A text-alternative version of the Building America webinar, Retrofitting Central Space Conditioning Strategies for Multifamily Buildings held on July 16, 2014.

218

Text-Alternative Version: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool Webcast  

Broader source: Energy.gov [DOE]

Below is the text-alternative version of the "Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool" webcast, held April 3, 2012.

219

ADEC II Universal SCR Retrofit System for On-road and Off-road...  

Broader source: Energy.gov (indexed) [DOE]

ADEC II Universal SCR Retrofit System for On-road and Off-road Diesel Engines Richard Carlson Extengine Transport Systems, LLC Fullerton, California 2006 DEER Conference Poster...

220

Deep Energy Retrofit Performance Metric Comparison: Eight California Case Studies  

SciTech Connect (OSTI)

In this paper we will present the results of monitored annual energy use data from eight residential Deep Energy Retrofit (DER) case studies using a variety of performance metrics. For each home, the details of the retrofits were analyzed, diagnostic tests to characterize the home were performed and the homes were monitored for total and individual end-use energy consumption for approximately one year. Annual performance in site and source energy, as well as carbon dioxide equivalent (CO{sub 2}e) emissions were determined on a per house, per person and per square foot basis to examine the sensitivity to these different metrics. All eight DERs showed consistent success in achieving substantial site energy and CO{sub 2}e reductions, but some projects achieved very little, if any source energy reduction. This problem emerged in those homes that switched from natural gas to electricity for heating and hot water, resulting in energy consumption dominated by electricity use. This demonstrates the crucial importance of selecting an appropriate metric to be used in guiding retrofit decisions. Also, due to the dynamic nature of DERs, with changes in occupancy, size, layout, and comfort, several performance metrics might be necessary to understand a project’s success.

Walker, Iain; Fisher, Jeremy; Less, Brennan

2014-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Field Assessment of Energy Audit Tools for Retrofit Programs  

SciTech Connect (OSTI)

This project focused on the use of home energy ratings as a tool to promote energy retrofits in existing homes. A home energy rating provides a quantitative appraisal of a home's asset performance, usually compared to a benchmark such as the average energy use of similar homes in the same region. Home rating systems can help motivate homeowners in several ways. Ratings can clearly communicate a home's achievable energy efficiency potential, provide a quantitative assessment of energy savings after retrofits are completed, and show homeowners how they rate compared to their neighbors, thus creating an incentive to conform to a social standard. An important consideration is how rating tools for the retrofit market will integrate with existing home energy service programs. For residential programs that target energy savings only, home visits should be focused on key efficiency measures for that home. In order to gain wide adoption, a rating tool must be easily integrated into the field process, demonstrate consistency and reasonable accuracy to earn the trust of home energy technicians, and have a low monetary cost and time hurdle for homeowners. Along with the Home Energy Score, this project also evaluated the energy modeling performance of SIMPLE and REM/Rate.

Edwards, J.; Bohac, D.; Nelson, C.; Smith, I.

2013-07-01T23:59:59.000Z

222

An Experimental and Analytical Evaluation of Wall And Window Retrofit Configurations: Supporting the Residential Retrofit Best Practices Guide  

SciTech Connect (OSTI)

A Retrofit Best Practices Guide was developed to encourage homeowners to consider energy conservation issues whenever they modify their siding or windows. In support of this guide, an experimental program was implemented to measure the performance of a number of possible wall siding and window retrofit configurations. Both thermal and air-leakage measurements were made for a 2.4 x 2.4 m (8 x 8 ft) wall section with and without a 0.9 x 1.2 m (3 x 4 ft) window. The windows tested were previously well-characterized at a dedicated window test facility. A computer model was also used to provide information for the Best Practices Guide. The experimental data for walls and windows were used in conjunction with this model to estimate the total annual energy savings for several typical houses in a number of different locations.

Stovall, Therese K [ORNL; Petrie, Thomas [ORNL; Kosny, Jan [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL; Hulvey, Kimberly D [ORNL

2007-11-01T23:59:59.000Z

223

E-Print Network 3.0 - auxiliary bus-bars routing Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: and VV cooling systems, vacuum pumping and fueling systems, LHe auxiliary cold box, and to route bus-bars... to the tokamak using air-cooled aluminum or copper bus...

224

Fuel Cell Transit Buses: ThunderPower Bus Evaluation at SunLine...  

Broader source: Energy.gov (indexed) [DOE]

Fuel Cell Transit Buses: ThunderPower Bus Evaluation at SunLine Transit Agency Fuel Cell Transit Buses: ThunderPower Bus Evaluation at SunLine Transit Agency Report details the...

225

Safety Shoe and Insole Reimbursement Form Requisitioner: -Submit to supervisor for signature  

E-Print Network [OSTI]

Safety Shoe and Insole Reimbursement Form Requisitioner: - Submit to supervisor for signature. _________________________________________________ POSITION ____________________________________________________________________ DID YOU PURCHASE SAFETY TOES Safety Shoes or other footwear under the provisions outlined in the Collective Agreement

Sinnamon, Gordon J.

226

University Reimbursement for Personal Expenditure Charged to a PCD (Procurement Card)  

E-Print Network [OSTI]

University Reimbursement for Personal Expenditure Charged to a PCD (Procurement Card) Funds: TAD01, TAD02, TAD04, TCPM1, TCUCE, TCUOP, THD01, THEHC, THELS, THEOC, THERA, THEXT, THF00, THOPR, TSXXX

de Lijser, Peter

227

Bus Fleet Type and Age Replacement Optimization: A case study utilizing King County Metro fleet data  

E-Print Network [OSTI]

1 Bus Fleet Type and Age Replacement Optimization: A case study utilizing King County Metro fleet and a hybrid bus. Employing real-world bus fleet data from King County Metro (Washington State, USA) multiple multiple fleets of buses with different types of buses serving different routes. For example, King County

Bertini, Robert L.

228

BEAM: Bus Encoding Based on Instruction-Set-Aware Memories Yazdan Aghaghiri  

E-Print Network [OSTI]

hardware overhead. The actual power savings of 85% for the instruction bus and 64% for the data bus were achieved for a per-line bus capacitance of 10pF. 1 Introduction With the rapid increase in the complexity consumption has become a key consideration in the design process. In every processor, a considerable number

Pedram, Massoud

229

An Arduino compatible CAN Bus architecture for sailing applications  

E-Print Network [OSTI]

An Arduino compatible CAN Bus architecture for sailing applications K´evin Bruget, Beno^it Clement architecture based on Arduino compatible boards, to be used as an alternative communication system for robotic applications. This combines both, the robustness of CAN and the accessibility of Arduino software

Paris-Sud XI, Université de

230

Design of a Programmable Bus for Microprocessor-Based Systems  

E-Print Network [OSTI]

to design a single interface on a personal computer (PC) card that satisfies the different needs between two or more devices. Devices on the bus can send to, and receive information from other devices for slower peripherals, and also for compatibility with older devices. In most modern PCs, the standard I

231

Text-Alternative Version of Building America Webinar: Low-e Storms: The Next "Big Thing" in Window Retrofits  

Broader source: Energy.gov [DOE]

Low-e Storms:  The Next “Big Thing” in Window RetrofitsOfficial Webinar Transcript (September 9, 2014)

232

Development of the bus joint for the ITER Central Solenoid  

SciTech Connect (OSTI)

The terminations of the Central Solenoid (CS) modules are connected to the bus extensions by joints located outside the CS in the gap between the CS and Torodial Field (TF) assemblies. These joints have very strict space limitations. Low resistance is a common requirement for all ITER joints. In addition, the CS bus joints will experience and must be designed to withstand significant variation in the magnetic field of several tenths of a Tesla per second during initiation of plasma. The joint resistance is specified to be less than 4 nOhm. The joints also have to be soldered in the field and designed with the possibility to be installed and dismantled in order to allow cold testing in the cold test facility. We have developed coaxial joints that meet these requirements and have demonstrated the feasibility to fabricate and assemble them in the vertical configuration. We introduced a coupling cylinder with superconducting strands soldered to the surface of the cable that can be installed in the ITER assembly hall and at the Cold Test Facility. This cylinder serves as a transition area between the CS module and the bus extension. We made two racetrack samples and tested four bus joints in our Joint Test Apparatus. Resistance of the bus joints was measured by a decay method and by a microvoltmeter; the value of the current was measured by the Hall probes. This measurement method was verified in the previous tests. The resistance of the joints varied insignificantly from 1.5 to 2 nOhm. One of the challenges associated with a soldered joint is the inability to use corrosive chemicals that are difficult to clean. This paper describes our development work on cable preparation, chrome removal, compaction, soldering, and final assembly and presents the test results.

Martovetsky, Nicolai N [ORNL] [ORNL; Irick, David Kim [ORNL] [ORNL; Kenney, Steven J [ORNL] [ORNL

2013-01-01T23:59:59.000Z

233

Measured energy savings and economics of retrofitting existing single- family homes: An update of the BECA-B database  

SciTech Connect (OSTI)

These appendices are the companion volume to report number LBL--28147 Vol.1, with the same title. The summary data tables include physical characteristics, energy consumption, savings, and the retrofit measures installed and their costs for each retrofit project. Each existing single family residential building'' retrofit project in the BECA-B database is described. 99 refs. (BM)

Cohen, S.D.; Goldman, C.A.; Harris, J.P.

1991-02-01T23:59:59.000Z

234

Sonoma House: Monitoring of the First U.S. Passive House Retrofit  

SciTech Connect (OSTI)

The Sonoma Deep Retrofit is a single-story deep retrofit project in the marine climate of Sonoma, California. The design was guided by Passive House principles which promote the use of very high levels of wall, ceiling, and floor insulation along with tight envelope construction to maintain a comfortable indoor environment with little or no need for conventional heating or cooling.

German, A.; Weitzel, B.; Backman, C.; Hoeschele, M.; Dakin, B.

2012-12-01T23:59:59.000Z

235

Retrofitting Vegas: Implementing Energy Efficiency in Two Las Vegas Test Homes  

SciTech Connect (OSTI)

In 2009, the state of Nevada received nearly forty million dollars in Neighborhood Stabilization Funds from the Department of Housing and Urban Development. The purpose of this funding was to stabilize communities that have suffered from foreclosures and abandonment. In an effort to provide guidance to local officials and maximize how effectively this NSP funding is utilized in retrofitting homes, CARB provided design specifications, energy modeling, and technical support for the Building America Retrofit Alliance (BARA) team and its local partners - Better Building Performance, Nevada Energy Star Partners Green Alliance, and Home Free Nevada - for two retrofit test homes. One home was to demonstrate a modest retrofit and the other a deep energy retrofit. Through this project, CARB has provided two robust solution packages for retrofitting homes built in this region between the 1980s and early 1990s without substantially inconveniencing the occupants. The two test homes, the Carmen and Sierra Hills, demonstrate how cost-effectively energy efficient upgrades can be implemented in the hot, dry climate of the Southwest. In addition, the homes were used as an educational experience for home performance professionals, building trades, remodelers, and the general public. In-field trainings on air-sealing, HVAC upgrades, and insulating were provided to local contractors during the retrofit and BARA documented these retrofits through a series of video presentations, beginning with a site survey and concluding with the finished remodel and test out.

Puttagunta, S.

2013-04-01T23:59:59.000Z

236

Expert Meeting Report: Interior Insulation Retrofit of Mass Masonry Wall Assemblies  

SciTech Connect (OSTI)

The Building Science Consortium held an Expert Meeting on Interior Insulation Retrofit of Mass Masonry Wall Assemblies on July 30, 2011 at the Westford Regency Hotel in Westford, MA. This report outlines the extensive information that was presented on assessment of risk factors for premature building deterioration due to interior insulation retrofits, and methods to reduce such risks.

Ueno, K.; Van Straaten, R.

2012-02-01T23:59:59.000Z

237

Using Auxiliary Gas Power for CCS Energy Needs in Retrofitted Coal Power Plants  

E-Print Network [OSTI]

1 Using Auxiliary Gas Power for CCS Energy Needs in Retrofitted Coal Power Plants by Sarah Bashadi and Policy Program #12;2 #12;3 Using Auxiliary Gas Power for CCS Energy Needs in Retrofitted Coal Power, a significant amount of excess power was produced using both gas turbine configurations. This excess power could

238

Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit  

E-Print Network [OSTI]

Air Leakage of US Homes: Regression Analysis and Improvements from Retrofit Wanyu R. Chan, Jeffrey,000 single-family detached homes have sufficient information for the analysis of air leakage in relation variability in normalized leakage. ResDB also contains the before and after retrofit air leakage measurements

239

The USDOE Forrestal Building Lighting Retrofit: Preliminary Analysis of Electricity Savings  

E-Print Network [OSTI]

In September of 1993 a 36,832 fixture lighting retrofit was completed at the United States Department of Energy Forrestal complex in Washington, D.C. This retrofit represents DOE's largest project to date that utilizes a Shared Energy Savings (SES...

Haberl, J. S.; Bou-Saada, T. E.; Vajda, E. J.; Shincovich, M.; D'Angelo III, L.; Harris, L.

1994-01-01T23:59:59.000Z

240

Seismic retrofit of concrete-encased riveted stiffened seat angle connections  

E-Print Network [OSTI]

Seismic retrofit of concrete-encased riveted stiffened seat angle connections Michel Bruneau Ottawa: Seismic retrofit, semi-rigid connections, concrete-encased, stiffened seat, ductile steel fuse, riveted frequently found in buildings constructed in the seismic zones of Eastern North America prior

Bruneau, Michel

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Instructions for "The Great Energy Predictor Shootout II: Measuring Retrofit Energy Savings"  

E-Print Network [OSTI]

and compare how those models can be used to calculate energy conservation retrofit savings. ASHRAE's TC 1.5 and TC 4.7 have authorized a "Building Energy Predictor Shootout II: Measuring Retrofit Energy Savings" which is the focus of this competition....

Haberl, J. S.; Kreider, J. F.

1994-01-01T23:59:59.000Z

242

An Evaluation of Energy-Saving Retrofits from the Texas LoanSTAR Program  

E-Print Network [OSTI]

This report discusses the LoanSTAR retrofit savings through December 1993 with an emphasis on the Constant Volume to Variable Air Volume air-handler retrofits. The report also summarizes several key findings about the LoanSTAR program which has 70...

Haberl, J. S.; Claridge, D. E.; Heneghan, T.; Sieggreen, R.; Sims, J.

1996-01-01T23:59:59.000Z

243

SunLine Transit Agency Advanced Technology Fuel Cell Bus Evaluation: First Results Report  

SciTech Connect (OSTI)

This report describes operations at SunLine Transit Agency for their newest prototype fuel cell bus and five compressed natural gas (CNG) buses. In May 2010, SunLine began operating its sixth-generation hydrogen fueled bus, an Advanced Technology (AT) fuel cell bus that incorporates the latest design improvements to reduce weight and increase reliability and performance. The agency is collaborating with the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to evaluate the bus in revenue service. This report provides the early data results and implementation experience of the AT fuel cell bus since it was placed in service.

Eudy, L.; Chandler, K.

2011-03-01T23:59:59.000Z

244

Newporter Apartments: Deep Energy Retrofit Short-Term Results  

SciTech Connect (OSTI)

This project demonstrates a path to meet the goal of the Building America program to reduce home energy use by 30% in multi-family buildings. The project demonstrates cost effective energy savings targets as well as improved comfort and indoor environmental quality (IEQ) associated with deep energy retrofits by a large public housing authority as part of a larger rehabilitation effort. The project focuses on a typical 1960's vintage low-rise multi-family apartment community (120 units in three buildings).

Gordon, A.; Howard, L.; Kunkle, R.; Lubliner, M.; Auer, D.; Clegg, Z.

2012-12-01T23:59:59.000Z

245

Glove port retrofit assembly and method of replacing components  

DOE Patents [OSTI]

What is disclosed is a system for retrofitting a sealed enclosure for performing work therein having an outer enclosure assembly configured to be clamped to the outer annular face of a port ring and form a sealed engagement with the outer annular surface of the port ring, a change assembly having an inner ring and an access element wherein the inner ring has a first annular cylinder body that is sized to be slidably received by the port ring and the access element is configured to be sealably and slidably positioned within the first annular cylinder body of the inner ring.

Giesen, Isaac M; Cournoyer, Michael E; Rael, David G

2014-11-18T23:59:59.000Z

246

MHD (magnetohydrodynamics) retrofit of a coal-fired generating plant  

SciTech Connect (OSTI)

This report presents the following appendices on the design of a coal-fired MHD retrofit: AVCO part load study; AVCO full load calculations; MSE mass balance calculations; Corette/MHD combined plant overall efficiency estimate; Corette boiler efficiency estimate; dynamic modeling and control simulation; combustor and nozzle scaling approach; field inductance and energy calculations; diagnostic instrumentation listing; equipment list; cost estimate factors; equipment and vendor costs data; CFFF test information; HRSR-ESP seed/ash calculations; and K{sub 2}/S molar ratio.

Not Available

1989-01-01T23:59:59.000Z

247

Retrofit Analysis of Older, Single Family Housing in San Antonio  

E-Print Network [OSTI]

Retrofit Analysis of Older, Single Family Housing in San Antonio Hazem Rashed-Ali, PhD, University of Texas at San Antonio CATEE 2013 Clean Air Through Energy Efficiency Conference December 16-18, 2013 San Antonio, TX 12/17/2013 ESL-KT-13...-12-05 CATEE 2013: Clean Air Through Energy Efficiency Conference, San Antonio, Texas Dec. 16-18 Background • Approximately one third of all residential housing units in US (about 40 million) were built before 1960 ( American Housing Survey, 2008), • City...

Rashed-Ali, H.

2013-01-01T23:59:59.000Z

248

Retrofit Energy Savings Estimation Model | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar PowerstoriesNrelPartnerType Jump to:CoStrategies (EC-LEDS) | OpentopicsRetrofit

249

Results from Development of Model Specifications for Multifamily Energy Retrofits  

SciTech Connect (OSTI)

Specifications, modeled after CSI MasterFormat, provide the trade contractors and builders with requirements and recommendations on specific building materials, components and industry practices that comply with the expectations and intent of the requirements within the various funding programs associated with a project. The goal is to create a greater level of consistency in execution of energy efficiency retrofits measures across the multiple regions a developer may work. IBACOS and Mercy Housing developed sample model specifications based on a common building construction type that Mercy Housing encounters.

Brozyna, K.

2012-08-01T23:59:59.000Z

250

Retrofit Ramp-Up Selected Projects* | Department of Energy  

Office of Environmental Management (EM)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "of EnergyEnergyENERGY TAXBalancedDepartmentRestrictions on Federal Employees AcceptanceRetrofit Ramp-Up

251

NREL Job Task Analysis: Retrofit Installer Technician (Revised)  

Broader source: Energy.gov (indexed) [DOE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary) "ofEarly Careerlumens_placard-green.eps MoreWSRC-STI-2007-00250ThisMarsh More DocumentsNOWEGISfromRetrofit

252

Boston solar retrofits: studies of solar access and economics  

SciTech Connect (OSTI)

Studies of solar access and solar retrofit economics are described for residential applications in the City of Boston. The study of solar access was based upon a random sample of 94 buildings; the sample was stratified to ensure a broad geographic representation from the city's various sections. Using available data on the heights and orientations of the sampled structures and surrounding buildings, each building's hourly access to sunlight was computed separately for the roof and south facing walls. These data were then aggregated by broad structural classifications in order to provide general measures of solar access. The second study was a comparative analysis of the economics of several solar heating and hot water systems. An active hot water system, installed using pre-assembled, commercially purchased equipment, was selected as a reference technology. A variety of measures of economic performance were computed for this system, with and without existing tax credits and under various financing arrangements. Next, a number of alternative approaches for solar space and water heating were identified from interviews with individuals and groups involved in solar retrofit projects in the Boston area. The objective was to identify approaches that many of those interviewed believe to be low-cost means of applying solar energy in residential settings. The approaches selected include thermal window covers, wall collectors, bread box water heaters, and sun spaces. Preliminary estimates of the performance of several representative designs were developed and the economics of these designs evaluated.

Shapiro, M.

1980-11-01T23:59:59.000Z

253

Analysis of institutional mechanisms affecting residential and commercial buildings retrofit  

SciTech Connect (OSTI)

Barriers to energy conservation in the residential and commercial sectors influence (1) the willingness of building occupants to modify their energy usage habits, and (2) the willingness of building owners/occupants to upgrade the thermal characteristics of the structures within which they live or work and the appliances which they use. The barriers that influence the willingness of building owners/occupants to modify the thermal efficiency characteristics of building structures and heating/cooling systems are discussed. This focus is further narrowed to include only those barriers that impede modifications to existing buildings, i.e., energy conservation retrofit activity. Eight barriers selected for their suitability for Federal action in the residential and commercial sectors and examined are: fuel pricing policies that in the short term do not provide enough incentive to invest in energy conservation; high finance cost; inability to evaluate contractor performance; inability to evaluate retrofit products; lack of well-integrated or one-stop marketing systems (referred to as lack of delivery systems); lack of precise or customized information; lack of sociological/psychological incentives; and use of the first-cost decision criterion (expanded to include short-term payback criterion for the commercial sector). The impacts of these barriers on energy conservation are separately assessed for the residential and commercial sectors.

Not Available

1980-09-01T23:59:59.000Z

254

Discharging a DC bus capacitor of an electrical converter system  

DOE Patents [OSTI]

A system and method of discharging a bus capacitor of a bidirectional matrix converter of a vehicle are presented here. The method begins by electrically shorting the AC interface of the converter after an AC energy source is disconnected from the AC interface. The method continues by arranging a plurality of switching elements of a second energy conversion module into a discharge configuration to establish an electrical current path from a first terminal of an isolation module, through an inductive element, and to a second terminal of the isolation module. The method also modulates a plurality of switching elements of a first energy conversion module, while maintaining the discharge configuration of the second energy conversion module, to at least partially discharge a DC bus capacitor.

Kajouke, Lateef A; Perisic, Milun; Ransom, Ray M

2014-10-14T23:59:59.000Z

255

BC Transit Fuel Cell Bus Project: Evaluation Results Report  

SciTech Connect (OSTI)

This report evaluates a fuel cell electric bus demonstration led by British Columbia Transit (BC Transit) in Whistler, Canada. BC Transit is collaborating with the California Air Resources Board and the U.S. Department of Energy's National Renewable Energy Laboratory to evaluate the buses in revenue service. This evaluation report covers two years of revenue service data on the buses from April 2011 through March 2013.

Eudy, L.; Post, M.

2014-02-01T23:59:59.000Z

256

Global Bus Rapid Transit (BRT) Database | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data CenterFranconia, Virginia: Energy Resources Jump to: navigation,Ohio: Energy Resources Jump to: navigation,OpenBus Rapid Transit (BRT)

257

Safety evaluation of a hydrogen fueled transit bus  

SciTech Connect (OSTI)

Hydrogen fueled vehicle demonstration projects must satisfy management and regulator safety expectations. This is often accomplished using hazard and safety analyses. Such an analysis has been completed to evaluate the safety of the H2Fuel bus to be operated in Augusta, Georgia. The evaluation methods and criteria used reflect the Department of Energy`s graded approach for qualifying and documenting nuclear and chemical facility safety. The work focused on the storage and distribution of hydrogen as the bus motor fuel with emphases on the technical and operational aspects of using metal hydride beds to store hydrogen. The safety evaluation demonstrated that the operation of the H2Fuel bus represents a moderate risk. This is the same risk level determined for operation of conventionally powered transit buses in the United States. By the same criteria, private passenger automobile travel in the United States is considered a high risk. The evaluation also identified several design and operational modifications that resulted in improved safety, operability, and reliability. The hazard assessment methodology used in this project has widespread applicability to other innovative operations and systems, and the techniques can serve as a template for other similar projects.

Coutts, D.A.; Thomas, J.K.; Hovis, G.L.; Wu, T.T. [Westinghouse Savannah River Co., Aiken, SC (United States)

1997-12-31T23:59:59.000Z

258

National Grid Deep Energy Retrofit Pilot, Massachusetts and Rhode Island (Fact Sheet)  

SciTech Connect (OSTI)

Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent "package" of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

Not Available

2014-03-01T23:59:59.000Z

259

Performance Results for Massachusetts and Rhode Island Deep Energy Retrofit Pilot Community  

SciTech Connect (OSTI)

Between December, 2009 and December, 2012 42 deep energy retrofit (DER) projects were completed through a DER pilot program sponsored by National Grid and conducted in Massachusetts and Rhode Island. 37 of these projects were comprehensive retrofits while 5 were partial DERs, meaning that high performance retrofit was implemented for a single major enclosure component or a limited number of major enclosure components. The 42 DER projects represent 60 units of housing. The comprehensive projects all implemented a consistent 'package' of measures in terms of the performance targeted for major building components. Projects exhibited some variations in the approach to implementing the retrofit package. Pre- and post-retrofit air leakage measurements were performed for each of the projects. Each project also reported information about project costs including identification of energy-related costs. Post-retrofit energy-use data was obtained for 29 of the DER projects. Post-retrofit energy use was analyzed based on the net energy used by the DER project regardless of whether the energy was generated on site or delivered to the site. Homeowner surveys were returned by 12 of the pilot participants. Based on the community experience, this DER package is expected to result in yearly source energy use near 110 MMBtu/year or approximately 40% below the Northeast regional average. Larger to medium sized homes that successful implement these retrofits can be expected to achieve source EUI that is comparable to Passive House targets for new construction. The community of DER projects show post-retrofit airtightness below 1.5 ACH50 to be eminently achievable.

Gates, C.; Neuhauser, K.

2014-03-01T23:59:59.000Z

260

Test Methods and Protocols for Environmental and Safety Hazards Associated with Home Energy Retrofits  

SciTech Connect (OSTI)

A number of health hazards and hazards to the durability of homes may be associated with energy retrofitting and home renovation projects. Among the hazards associated with energy retrofit work, exposure to radon is thought to cause more than 15,000 deaths per year in the U.S., while carbon monoxide poisoning results in about 20,000 injuries and 450 deaths per year. Testing procedures have been developed for identifying and quantifying hazards during retrofitting. These procedures commonly include a battery of tests to screen combustion appliances for safe operation, including worst case depressurization measurement, backdrafting (spillage) under depressurized or normal conditions, and carbon monoxide production.

Cautley, D.; Viner, J.; Lord, M.; Pearce, M.

2012-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Standard Measurement and Verification Plan for Lighting Retrofit Projects for Buildings and Building Sites  

SciTech Connect (OSTI)

This document provides a framework for standard measurement and verification (M&V) of lighting retrofit and replacement projects. It was developed to provide site owners, contractors, and other involved organizations with the essential elements of a robust M&V plan for lighting projects. It includes details on all aspects of effectively measuring light levels of existing and post-retrofit projects, conducting power measurement, and developing cost-effectiveness analysis. This framework M&V plan also enables consistent comparison among similar lighting projects, and may be used to develop M&V plans for non--lighting-technology retrofits and new installations.

Richman, Eric E.

2012-10-31T23:59:59.000Z

262

SunLine Transit Agency Advanced Technology Fuel Cell Bus Evaluation: Fourth Results Report  

SciTech Connect (OSTI)

SunLine Transit Agency, which provides public transit services to the Coachella Valley area of California, has demonstrated hydrogen and fuel cell bus technologies for more than 10 years. In May 2010, SunLine began demonstrating the advanced technology (AT) fuel cell bus with a hybrid electric propulsion system, fuel cell power system, and lithium-based hybrid batteries. This report describes operations at SunLine for the AT fuel cell bus and five compressed natural gas buses. The U.S. Department of Energy's National Renewable Energy Laboratory (NREL) is working with SunLine to evaluate the bus in real-world service to document the results and help determine the progress toward technology readiness. NREL has previously published three reports documenting the operation of the fuel cell bus in service. This report provides a summary of the results with a focus on the bus operation from February 2012 through November 2012.

Eudy, L.; Chandler, K.

2013-01-01T23:59:59.000Z

263

SunLine Transit Agency Advanced Technology Fuel Cell Bus Evaluation: Third Results Reports  

SciTech Connect (OSTI)

This report describes operations at SunLine Transit Agency for their newest prototype fuel cell bus and five compressed natural gas (CNG) buses. In May 2010, SunLine began operating its sixth-generation hydrogen fueled bus, an Advanced Technology (AT) fuel cell bus that incorporates the latest design improvements to reduce weight and increase reliability and performance. The agency is collaborating with the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to evaluate the bus in revenue service. NREL has previously published two reports documenting the operation of the fuel cell bus in service. This report provides a summary of the results with a focus on the bus operation from July 2011 through January 2012.

Eudy, L.; Chandler, K.

2012-05-01T23:59:59.000Z

264

Distribution and Room Air Mixing Risks to Retrofitted Homes  

SciTech Connect (OSTI)

?Energy efficiency upgrades reduce heating and cooling loads on a house. With enough load reduction and if the HVAC system warrants replacement, the HVAC system is often upgraded with a more efficient, lower capacity system that meets the loads of the upgraded house. For a single-story house with ceiling supply air diffusers, ducts are often removed and upgraded. For houses with ducts that are embedded in walls, the cost of demolition precludes the replacement of ducts. The challenge with the use of existing ducts is that the reduced airflow creates a decreased throw at the supply registers, and the supply air and room air do not mix well, leading to potential thermal comfort complaints. This project investigates this retrofit scenario. The issues and solutions discussed here are relevant to all climate zones, with emphasis on climates that require cooling.

Burdick, A.

2014-12-01T23:59:59.000Z

265

Indoor Air Quality and Ventilation in Residential Deep Energy Retrofits  

SciTech Connect (OSTI)

Because airtightening is a significant part of Deep Energy Retrofits (DERs), concerns about ventilation and Indoor Air Quality (IAQ) have emerged. To investigate this, ventilation and IAQ were assessed in 17 non-smoking California Deep Energy Retrofit homes. Inspections and surveys were used to assess household activities and ventilation systems. Pollutant sampling performed in 12 homes included six-day passive samples of nitrogen dioxide (NO2), formaldehyde and air exchange rate (AER); time-resolved data loggers were used to measure particle counts. Half of the homes provided continuous mechanical ventilation. Despite these homes being twice as airtight (3.0 and 7.6 ACH50, respectively), their median AER was indistinguishable from naturally vented homes (0.36 versus 0.37 hr--1). Numerous problems were found with ventilation systems; however, pollutant levels did not reach levels of concern in most homes. Ambient NO2 standards were exceeded in some gas cooking homes that used legacy ranges with standing pilots, and in Passive House-style homes without range hoods exhausted to outside. Cooking exhaust systems were installed and used inconsistently. The majority of homes reported using low-emitting materials, and formaldehyde levels were approximately half those in conventional new CA homes (19.7 versus 36 ?g/m3), with emissions rates nearly 40percent less (12.3 versus 20.6 ?g/m2/hr.). Presence of air filtration systems led to lower indoor particle number concentrations (PN>0.5: 8.80E+06 PN/m3 versus 2.99E+06; PN>2.5: 5.46E+0.5 PN/m3 versus 2.59E+05). The results indicate that DERs can provide adequate ventilation and IAQ, and that DERs should prioritize source control, particle filtration and well-designed local exhaust systems, while still providing adequate continuous ventilation.

Less, Brennan; Walker, Iain

2014-06-01T23:59:59.000Z

266

Advanced Rooftop Control (ARC) Retrofit: Field-Test Results  

SciTech Connect (OSTI)

The multi-year research study was initiated to find solutions to improve packaged equipment operating efficiency in the field. Pacific Northwest National Laboratory (PNNL), with funding from the U.S. Department of Energy’s (DOE’s) Building Technologies Office (BTO) and Bonneville Power Administration (BPA) conducted this research, development and demonstration (RD&D) study. Packaged equipment with constant speed supply fans is designed to provide ventilation at the design rate at all times when the fan is operating as required by building code. Although there are a number of hours during the day when a building may not be fully occupied or the need for ventilation is lower than designed, the ventilation rate cannot be adjusted easily with a constant speed fan. Therefore, modulating the supply fan in conjunction with demand controlled ventilation (DCV) will not only reduce the coil energy but also reduce the fan energy. The objective of this multi-year research, development and demonstration project was to determine the magnitude of energy savings achievable by retrofitting existing packaged rooftop air conditioners with advanced control strategies not ordinarily used for packaged units. First, through detailed simulation analysis, it was shown that significant energy (between 24% and 35%) and cost savings (38%) from fan, cooling and heating energy consumption could be realized when packaged air conditioning units with gas furnaces are retrofitted with advanced control packages (combining multi-speed fan control, integrated economizer controls and DCV). The simulation analysis also showed significant savings for heat pumps (between 20% and 60%). The simulation analysis was followed by an extensive field test of a retrofittable advanced rooftop unit (RTU) controller.

Wang, Weimin; Katipamula, Srinivas; Ngo, Hung; Underhill, Ronald M.; Taasevigen, Danny J.; Lutes, Robert G.

2013-07-31T23:59:59.000Z

267

Effects of Catalysts on Emissions from Heavy-Duty Diesel Retrofits...  

Broader source: Energy.gov (indexed) [DOE]

9 Directions in Engine-Efficiency and Emissions Research (DEER) Conference Dearborn, Michigan, August 3-6, 2009 Effects of Catalysts on Emissions from Heavy-Duty Diesel Retrofits...

268

Trial Demonstration of Area Lighting Retrofit: Yuma Border Patrol, Yuma Arizona  

SciTech Connect (OSTI)

The Yuma Sector Border Patrol Area is a high flux lighting application in a high temperature environment, presenting a formidable challenge for light-emitting diodes (LEDs). This retrofit is an Energy Savings Performance Contract ENABLE project under the U.S. Department of Energy (DOE) Federal Energy Management Program. If high flux LED technology performs well in a region with high ambient temperature and solar radiation, it can perform well in most outdoor environments. The design process for the Yuma retrofit has already provided valuable knowledge to CBP and DOE. The LED lighting system selected for the retrofit is expected to reduce energy consumption 69% compared to the incumbent quartz metal halide (QMH) lighting system. If the LED lighting system is installed, GATEWAY will continue to document and disseminate information regarding the installation and long-term performance so that others may also gain valuable knowledge from the Yuma Sector Border Patrol Area lighting retrofit.

Wilkerson, Andrea M.; McCullough, Jeffrey J.

2014-12-30T23:59:59.000Z

269

Cost Savings and Energy Reduction: Bi-Level Lighting Retrofits in Multifamily Buildings  

E-Print Network [OSTI]

Community Environmental Center implements Bi- Level Lighting fixtures as a component of cost-effective multifamily retrofits. These systems achieve substantial energy savings by automatically reducing lighting levels when common areas are unoccupied...

Ackley, J.

2010-01-01T23:59:59.000Z

270

Measuring Energy-Saving Retrofits: Experiences from the LoanSTAR Program  

E-Print Network [OSTI]

school, and local government buildings. As part of this program, a first-of-its-kind, statewide Monitoring and Analysis Program (MAP) was established to verify energy and dollar savings of the retrofits, reduce energy costs by identifying operational...

Claridge, D. E.; Heffington, W. M.; O'Neal, D. L.; Turner, W. D.; Haberl, J. S.; Reddy, T. A.

2005-09-27T23:59:59.000Z

271

Retrofit of the Local 150 of International Union of Operating Engineers  

Broader source: Energy.gov [DOE]

Project objectives: Demonstrate the reduced first cost impact of smart geothermal design and technology. Demonstrate smart geothermal innovations in system efficiency, especially in the building-earth interaction. Demonstrate an economical and repeatable approach to district, hybrid retrofit GHP systems.

272

National Residential Efficiency Measures Database Aimed at Reducing Risk for Residential Retrofit Industry (Fact Sheet)  

SciTech Connect (OSTI)

This technical highlight describes NREL research to develop a publicly available database of energy retrofit measures containing performance characteristics and cost estimates for nearly 3,000 measures. Researchers at the U.S. Department of Energy (DOE) National Renewable Energy Laboratory (NREL) have developed the National Residential Efficiency Measures Database, a public database that characterizes the performance and costs of common residential energy efficiency measures. The data are available for use in software programs that evaluate cost-effective retrofit measures to improve the energy efficiency of residential buildings. The database provides a single, consistent source of current data for DOE and private-sector energy audit and simulation software tools and the retrofit industry. The database will reduce risk for residential retrofit industry stakeholders by providing a central, publicly vetted source of up-to-date information.

Not Available

2012-01-01T23:59:59.000Z

273

Analysis Methodology for Large Organizations' Investments in Energy Retrofit of Buildings  

E-Print Network [OSTI]

This paper presents a formal methodology that supports large organizations' investments in energy retrofit of buildings. The methodology is a scalable modeling approach based on normative models and Bayesian calibration. Normative models are a light...

Heo, Y.; Augenbroe, G.

2011-01-01T23:59:59.000Z

274

Pre-Retrofit Lighting Study at the University of Texas at Arlington, Texas  

E-Print Network [OSTI]

Audit Report for the site, completed in 1991, recommended a lighting retrofit that included delamping, relamping with high efficiency lamps, the installation of high efficiency electronic ballasts, and the installation of specular reflectors. However...

Houcek, J. K.; Claridge, D. E.; Haberl, J. S.

1993-01-01T23:59:59.000Z

275

Seismic fragility and retrofitting for a reinforced concrete flat-slab structure  

E-Print Network [OSTI]

The effectiveness of seismic retrofitting applied to enhance seismic performance was assessed for a five-story reinforced concrete (RC) flat-slab building structure in the central United States. In addition to this, an assessment of seismic...

Bai, Jong-Wha

2004-09-30T23:59:59.000Z

276

Determination of Retrofit Savings Using a Calibrated Building Energy Simulation Model  

E-Print Network [OSTI]

This paper presents the development of a methodology to determine retrofit energy savings in buildings when few measured preretrofit data are available. Calibration of the DOE-2 building energy analysis computer program for a 250,000 ft2 building...

Reddy, S. N.; Hunn, B. D.; Hood, D. B.

1994-01-01T23:59:59.000Z

277

Assessing methods for predicting retrofit energy savings in buildings : case study of a Norwegian school  

E-Print Network [OSTI]

This work investigates methods for predicting retrofit energy savings in existing Norwegian buildings. A case study is performed on a 30 year old primary school in Trondheim, Norway. The energy consumption in the school ...

Ricker, Elizabeth, S.M. (Elizabeth Ann). Massachusetts Institute of Technology

2008-01-01T23:59:59.000Z

278

Philadelphia Gas Works- Commercial and Industrial EnergySense Retrofit Program (Pennsylvania)  

Broader source: Energy.gov [DOE]

Philadelphia Gas Works' (PGW) Commercial and Industrial Retrofit Incentive Program is part of EnergySense, PGW’s portfolio of energy efficiency programs designed to help customers save energy and...

279

Building America Webinar: Standardized Retrofit Packages — What Works to Meet Consistent Levels of Performance?  

Broader source: Energy.gov [DOE]

This webinar will focus on specific Building America projects that have examined methods to consistently meet high levels of energy performance in existing homes, with a focus on retrofit packages that can be replicated across many homes.

280

Modelling Urban scale Retrofit, Pathways to 2050 Low Carbon Residential Building Stock   

E-Print Network [OSTI]

A bottom up engineering modelling approach has been used to investigate the pathways to 2050 low carbon residential building stock. The impact of housing retrofit, renewable technologies, occupant behaviour, and grid decarbonisation is measured at a...

Lannon, Simon; Georgakaki, Aliki; Macdonald, Stuart

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

State Energy Program (SEP) Strengthening Building Retrofit Markets and Stimulating Energy Efficiency Action  

Broader source: Energy.gov [DOE]

National Energy Technology Laboratory (NETL) presentation on State Energy Program (SEP) Strengthening Building Retrofit Markets and Stimulating Energy Efficiency Action DE-FOA-0000251, Stimulating Energy Efficiency Action from State Public Utility Commissions DE-FOA-0000266

282

Using the Street and Parking Facility Lighting Retrofit Financial Analysis Tool  

Broader source: Energy.gov [DOE]

This August 22, 2013 webinar provided a guided walk-through of the Street and Parking Facility Lighting Retrofit Financial Analysis Tool. Developed by a partnership of the DOE Municipal Solid-State...

283

Webcast: Municipal Solid-State Street Lighting Consortium Retrofit Financial Analysis Tool  

Broader source: Energy.gov [DOE]

This April 3, 2012 webcast presented information about the Retrofit Financial Analysis Tool developed by DOE"s Municipal Solid-State Street Lighting Consortium. Doug Elliott of Pacific Northwest...

284

Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst...  

Broader source: Energy.gov (indexed) [DOE]

Retrofit and Testing of a Pre-Turbo, Diesel Oxidation Catalyst on a Tier 0, SD60M Freight Locomotive Achieving Over 50% PM Reduction Don Newburry Research & Development Manager...

285

Seismic Assessment and Retrofit of Existing Multi-Column Bent Bridges  

E-Print Network [OSTI]

Seismic Assessment and Retrofit of Existing Multi-Column Bent Bridges By Cole C. Mc ................................................................................................................................... 6 Seismic Activity in Western Washington State Approach ­ Bridge Modeling .............................................11 Seismic Excitations

286

State-of-the-Art Thermal Energy Storage Retrofit at a Large Manufacturing Facility  

E-Print Network [OSTI]

This paper will describe the existing conditions, strategic planning, feasibility study, economic analysis, design, specification, construction, and project management for the 2.9 megawatt “full shift” chilled water thermal energy storage retrofit...

Fiorino, D.

287

Standard Measurement & Verification Plan for Lighting Equipment Retrofit or Replacement Projects  

SciTech Connect (OSTI)

This document provides a framework for a standard Measurement and Verification (M&V) plan for lighting projects. It was developed to support cost-effective retrofits (partial and complete replacements) of lighting systems and is intended to provide a foundation for an M&V plan for a lighting retrofit utilizing a "best practice" approach, and to provide guidance to site owners, contractors, and other involved organizations on what is essential for a robust M&V plan for lighting projects. This document provides examples of appropriate elements of an M&V plan, including the calculation of expected energy savings. The standard M&V plan, as provided, also allows for consistent comparison with other similar lighting projects. Although intended for lighting retrofit applications, M&V plans developed per this framework document may also be used for other non-lighting technology retrofits and new installations.

Richman, Eric E.

2009-11-04T23:59:59.000Z

288

Building America Webinar: Low-E Storms: The Next Big Thing in Window Retrofits  

Broader source: Energy.gov [DOE]

Until recently, energy-efficient window retrofit options have largely been limited to repair or replacement; leaving the homeowner to decide between affordability and deeper energy savings.  A new...

289

JOURNAL OF STRUCTURAL ENGINEERING / SEPTEMBER 2000 / 1017 SEISMIC RETROFITTING OF LOW-RISE MASONRY AND CONCRETE  

E-Print Network [OSTI]

the architectural aesthetics of the building. Hence, an alternative method of retrofitting is worth considering Hall, Dept. of Civ., Struct., and Envir. Engrg., State Univ. of New York, Buffalo, NY 14260. E

Bruneau, Michel

290

Effects of moisture on debonding in FRP-retrofitted concrete systems  

E-Print Network [OSTI]

FRP (fiber reinforced polymer) retrofit systems for reinforced concrete (RC) structures have been widely used in the past 10 years, and numerous studies on its short-term debonding behavior have been conducted extensively. ...

Tuakta, Chakrapan, 1980-

2011-01-01T23:59:59.000Z

291

Using auxiliary gas power for CCS energy needs in retrofitted coal power plants  

E-Print Network [OSTI]

Post-combustion capture retrofits are expected to a near-term option for mitigating CO 2 emissions from existing coal-fired power plants. Much of the literature proposes using power from the existing coal plant and thermal ...

Bashadi, Sarah (Sarah Omer)

2010-01-01T23:59:59.000Z

292

TCAT to Receive Ithaca's First 'Cutting-Edge' Fuel Cell Bus ...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Archived News Stories Latest News TCAT to Receive Ithaca's First 'Cutting-Edge' Fuel Cell Bus 2 Cornellians receive Distinguished Scholar Award Versatile polymer film...

293

Congestion protection for public transportation : strategies and application to MBTA bus route 66.  

E-Print Network [OSTI]

??Protecting transit routes from congestion is necessary for improving performance and reliability of bus service. Different congestion protection strategies that have been used across the… (more)

Boll, Christopher Michael

2008-01-01T23:59:59.000Z

294

The prediction of bus arrival time using Automatic Vehicle Location Systems data  

E-Print Network [OSTI]

2.4.4 Kalman Filtering Models ..................................................................22 2.4.5 Artificial Neural Network Models ....................................................22 2.5 BUS TRAVEL TIME PREDICTION...

Jeong, Ran Hee

2005-02-17T23:59:59.000Z

295

Connecticut Transit (CTTRANSIT) Fuel Cell Transit Bus: Second Evaluation Report and Appendices  

Broader source: Energy.gov [DOE]

This report describes operations at Connecticut Transit (CTTRANSIT) in Hartford for one prototype fuel cell bus and three new diesel buses operating from the same location.

296

Superconducting link bus design for the accelerator project for upgrade of LHC  

SciTech Connect (OSTI)

The Accelerator Project for Upgrade of LHC (APUL) is a U.S. project participating in and contributing to CERN's Large Hadron Collider (LHC) upgrade program. Fermi National Accelerator Laboratory in collaboration with Brookhaven National Laboratory was developing sub-systems for the upgrade of the LHC final focus magnet systems. Part of the upgrade called for various lengths of superconducting power transmission lines known as SC Links which were up to 100 m long. The SC Link electrically connects the current leads in the Distribution Feed Boxes to the interaction region magnets. The SC Link is an extension of the magnet bus housed within a cryostat. The present concept for the bus consists of 22 power cables, 4 x 13 kA, 2 x 7 kA, 8 x 2.5 kA and 8 x 0.6 kA bundled into one bus. Different cable and strand possibilities were considered for the bus design including Rutherford cable. The Rutherford cable bus design potentially would have required splices at each sharp elbow in the SC Link. The advantage of the round bus design is that splices are only required at each end of the bus during installation at CERN. The round bus is very flexible and is suitable for pulling through the cryostat. Development of the round bus prototype and of 2 splice designs is described in this paper. Magnetic analysis and mechanical test results of the 13 kA cable and splices are presented.

Nobrega, F.; Brandt, J.; Cheban, S.; Feher, S.; Kaducak, M.; Kashikhin, V.; Peterson, T.; /Fermilab

2011-06-01T23:59:59.000Z

297

Superconducting link bus design for the accelerator project for upgrade of LHC  

SciTech Connect (OSTI)

The Accelerator Project for Upgrade of LHC (APUL) is a U.S. project participating in and contributing to CERN's Large Hadron Collider (LHC) upgrade program. Fermi National Accelerator Laboratory in collaboration with Brookhaven National Laboratory was developing sub-systems for the upgrade of the LHC final focus magnet systems. Part of the upgrade called for various lengths of superconducting power transmission lines known as SC Links which were up to 100 m long. The SC Link electrically connects the current leads in the Distribution Feed Boxes to the interaction region magnets. The SC Link is an extension of the magnet bus housed within a cryostat. The present concept for the bus consists of 22 power cables, 4 x 13 kA, 2 x 7 kA, 8 x 2.5 kA and 8 x 0.6 kA bundled into one bus. Different cable and strand possibilities were considered for the bus design including Rutherford cable. The Rutherford cable bus design potentially would have required splices at each sharp elbow in the SC Link. The advantage of the round bus design is that splices are only required at each end of the bus during installation at CERN. The round bus is very flexible and is suitable for pulling through the cryostat. Development of the round bus prototype and of 2 splice designs is described in this paper. Magnetic analysis and mechanical test results of the 13 kA cable and splices are presented.

Nobrega, F.; Brandt, J.; Cheban, S.; Feher, S.; Kaducak, M.; Kashikhin, V.; Peterson, T.; /Fermilab

2010-08-01T23:59:59.000Z

298

E-Print Network 3.0 - alternative fuels bus Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The bus ... Source: DOE Office of Energy Efficiency and Renewable Energy, Hydrogen, Fuel Cells and Infrastructure Technologies Program Collection: Energy Storage, Conversion...

299

Fuel Cell Transit Buses: ThunderPower Bus Evaluation at SunLine...  

Broader source: Energy.gov (indexed) [DOE]

ThunderPower Bus Evaluation at SunLine Transit Agency Transit Buses Hydrogen, Fuel Cells & Infrastructure Technologies Program Fuel Cell A Strong Energy Portfolio for a Strong...

300

Multifamily Retrofit Project Manager Job/Task Analysis and Report: September 2013  

SciTech Connect (OSTI)

The development of job/task analyses (JTAs) is one of three components of the Guidelines for Home Energy Professionals project and will allow industry to develop training resources, quality assurance protocols, accredited training programs, and professional certifications. The Multifamily Retrofit Project Manager JTA identifies and catalogs all of the tasks performed by multifamily retrofit project managers, as well as the knowledge, skills, and abilities (KSAs) needed to perform the identified tasks.

Owens, C. M.

2013-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Decision process for the retrofit of municipal buildings with solar energy systems: a technical guide  

SciTech Connect (OSTI)

As a background for solar applications, the following topics are covered: solar systems and components for retrofit installations; cost, performance, and quality considerations; and financing alternatives for local government. The retrofit decision process is discussed as follows: pre-screening of buildings, building data requirements, the energy conservation audit, solar system sizing and economics, comparison of alternatives, and implementation. Sample studies are presented for the West Valley Animal Shelter and the Hollywood Police Station. (MHR)

None

1980-11-01T23:59:59.000Z

302

Retrofitting the domestic built environment: investigating household perspectives towards energy efficiency technologies and behaviour  

E-Print Network [OSTI]

]. Retrofitting homes is a complex task con- flated by multiple factors, ranging from pure economics to subjective psychology [Dixon & Eames, 2013; Institution of Mechanical Engineers, 2009; Kelly, 2009; Lior, 2010; Stafford et al., 2012]. Such complexity invites... cultural heritage research, and geo-technical soil surveying. Therefore, in order to delimit a more focused scope 3 1. Introduction of research, this thesis specifically investigated improving the uptake of energy ef- ficiency retrofits in the domestic...

Pelenur, Marcos

2014-03-04T23:59:59.000Z

303

Evaluation of a Multifamily Retrofit in Climate Zone 5, Boulder, Colorado (Fact Sheet)  

SciTech Connect (OSTI)

In 2009, a 37-unit apartment complex located in Boulder, Colorado, underwent an energy retrofit to comply with Boulder SmartRegs Ordinance, a mandate that requires all rental properties to meet certain energy efficiency standards by 2018. The Consortium of Advanced Residential Buildings (CARB), a U.S. Department of Energy Building America team, worked with city planners and building owners to evaluate this program and recently completed a case study evaluating the effectiveness of a collection of retrofit measures.

Not Available

2013-11-01T23:59:59.000Z

304

Calculating Energy and Demand Retrofit Savings for Victoria High School: Interim Report  

E-Print Network [OSTI]

ESL-TR-92/12-03 Calculating Energy and Demand Retrofit Savings For Victoria High School Yue Liu, T. Agami Reddy, S. Katipamula and David E. Claridge. Interim Report Energy Systems Laboratory Texas A&M University College Station, TX 77843 December... 1992 Calculating Energy and Demand Retrofit Savings For Victoria High School Yue Liu, T. Agami Reddy, S. Katipamula and David E. Claridge. Interim Report Energy Systems Laboratory Texas A&M University College Station, TX 77843 December 1992 Abstract...

Liu, Y.; Reddy, T. A.; Katipamula, S.; Claridge, D. E.

1992-01-01T23:59:59.000Z

305

Group Home Energy Efficiency Retrofit for 30% Energy Savings: Washington, D.C. (Fact Sheet)  

SciTech Connect (OSTI)

Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes - such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study's results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

Not Available

2013-11-01T23:59:59.000Z

306

Case study field evaluation of a systems approach to retrofitting a residential HVAC system  

SciTech Connect (OSTI)

This case study focusing on a residence in northern California was undertaken as a demonstration of the potential of a systems approach to HVAC retrofits. The systems approach means that other retrofits that can affect the HVAC system are also considered. For example, added building envelope insulation reduces building loads so that smaller capacity HVAC system can be used. Secondly, we wanted to examine the practical issues and interactions with contractors and code officials required to accomplish the systems approach because it represents a departure from current practice. We identified problems in the processes of communication and installation of the retrofit that led to compromises in the final energy efficiency of the HVAC system. These issues must be overcome in order for HVAC retrofits to deliver the increased performance that they promise. The experience gained in this case study was used to optimize best practices guidelines for contractors (Walker 2003) that include building diagnostics and checklists as tools to assist in ensuring the energy efficiency of ''house as a system'' HVAC retrofits. The best practices guidelines proved to be an excellent tool for evaluating the eight existing homes in this study, and we received positive feedback from many potential users who reviewed and used them. In addition, we were able to substantially improve the energy efficiency of the retrofitted case study house by adding envelope insulation, a more efficient furnace and air conditioner, an economizer and by reducing duct leakage.

Walker, Iain S.; McWiliams, Jennifer A.; Konopacki, Steven J.

2003-09-01T23:59:59.000Z

307

BC Transit Fuel Cell Bus Project Evaluation Results: Second Report  

SciTech Connect (OSTI)

Second report evaluating a fuel cell electric bus (FCEB) demonstration led by British Columbia Transit (BC Transit) in Whistler, Canada. BC Transit is collaborating with the California Air Resources Board and the U.S. Department of Energy's National Renewable Energy Laboratory to evaluate the buses in revenue service. NREL published its first report on the demonstration in February 2014. This report is an update to the previous report; it covers 3 full years of revenue service data on the buses from April 2011 through March 2014 and focuses on the final experiences and lessons learned.

Eudy, L.; Post, M.

2014-09-01T23:59:59.000Z

308

DOE HQ Shuttle Bus Schedule and Route | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy UsageAUDITVehiclesTankless orAChiefAppropriation FYG 242.1-1 DOE G20.7 DOE7Shuttle Bus

309

NREL Energy DataBus/Resources | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar Powerstories onFocus AreaDataBus Jump to: navigation, search View the Databus

310

UMBC POLICY ON REIMBURSEMENT FOR BUSINESS MEALS AND PURCHASE OF FOOD SERVICES OTHER THAN EMPLOYEE TRAVEL  

E-Print Network [OSTI]

UMBC POLICY ON REIMBURSEMENT FOR BUSINESS MEALS AND PURCHASE OF FOOD SERVICES OTHER THAN EMPLOYEE and the purchase of food services is intended to define the conditions under which the University will pay directly The purpose of this document is to describe allowable meal and food service purchases using University funds

Adali, Tulay

311

v. 1.2 May 29, 2012 Chapter 12 TRAINING AND DEVELOPMENT/TUITION REIMBURSEMENT  

E-Print Network [OSTI]

on University time. Such employer-required training (other than recognized on-the-job training programs of C or greater. Accredited institutions of Higher Education available for reimbursement, the current classification or classification series. Exceptions to this requirement may be #12;v. 1.2 May 29

Sheridan, Jennifer

312

Fuel Cell Bus Takes a Starring Role in the BurbankBus Fleet, Fuel Cell Technologies Program (FCTP) (Fact Sheet)  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-UpHeatMulti-Dimensional ElectricalEnergy Frozen Telescope Looks to Ends101BurbankBus'

313

Building America Case Study: Performance of a Hot-Dry Climate Whole House Retrofit, Stockton, California (Fact Sheet)  

SciTech Connect (OSTI)

The Stockton house retrofit is a two-story tudor style single family deep retrofit in the hot-dry climate of Stockton, CA. The home is representative of a deep retrofit option of the scaled home energy upgrade packages offered to targeted neighborhoods under the pilot Large-Scale Retrofit Program (LSRP) administered by the Alliance for Residential Building Innovation (ARBI). Deep retrofit packages expand on the standard package by adding HVAC, water heater and window upgrades to the ducting, attic and floor insulation, domestic hot water insulation, envelope sealing, lighting and ventilation upgrades. Site energy savings with the deep retrofit were 23% compared to the pre-retrofit case, and 15% higher than the savings estimated for the standard retrofit package. Energy savings were largely a result of the water heater upgrade, and a combination of the envelope sealing, insulation and HVAC upgrade. The HVAC system was of higher efficiency than the building code standard. Overall the financed retrofit would have been more cost effective had a less expensive HVAC system been selected and barriers to wall insulation remedied. The homeowner experienced improved comfort throughout the monitored period and was satisfied with the resulting utility bill savings.

ARBI

2014-09-01T23:59:59.000Z

314

Building America Whole-House Solutions for Existing Homes: Group Home Energy Efficiency Retrofit for 30% Energy Savings (Fact Sheet)  

Broader source: Energy.gov [DOE]

This project studies the specification, implementation, and energy savings from an energy efficiency retrofit in a group home, with an energy savings goal of 30%.

315

NREL's Hydrogen-Powered Bus Serves as Showcase for Advanced Vehicle Technologies (AVT) (Brochure)  

SciTech Connect (OSTI)

Brochure describes the hydrogen-powered internal combustion engine (H2ICE) shuttle bus at NREL. The U.S. Department of Energy (DOE) is funding the lease of the bus from Ford to demonstrate market-ready advanced technology vehicles to visitors at NREL.

Not Available

2010-08-01T23:59:59.000Z

316

Drive Cycle Analysis, Measurement of Emissions and Fuel Consumption of a PHEV School Bus: Preprint  

SciTech Connect (OSTI)

The National Renewable Energy Laboratory (NREL) collected and analyzed real-world school bus drive cycle data and selected similar standard drive cycles for testing on a chassis dynamometer. NREL tested a first-generation plug-in hybrid electric vehicle (PHEV) school bus equipped with a 6.4L engine and an Enova PHEV drive system comprising a 25-kW/80 kW (continuous/peak) motor and a 370-volt lithium ion battery pack. A Bluebird 7.2L conventional school bus was also tested. Both vehicles were tested over three different drive cycles to capture a range of driving activity. PHEV fuel savings in charge-depleting (CD) mode ranged from slightly more than 30% to a little over 50%. However, the larger fuel savings lasted over a shorter driving distance, as the fully charged PHEV school bus would initially operate in CD mode for some distance, then in a transitional mode, and finally in a charge-sustaining (CS) mode for continued driving. The test results indicate that a PHEV school bus can achieve significant fuel savings during CD operation relative to a conventional bus. In CS mode, the tested bus showed small fuel savings and somewhat higher nitrogen oxide (NOx) emissions than the baseline comparison bus.

Barnitt, R.; Gonder, J.

2011-04-01T23:59:59.000Z

317

A quality control framework for bus schedule reliability Jie Lin a,*, Peng Wang b  

E-Print Network [OSTI]

A quality control framework for bus schedule reliability Jie Lin a,*, Peng Wang b , Darold T and demonstrates a quality control framework for bus schedule reliability. Automatic vehicle loca- tion (AVL demonstrating that it can provide quick and accurate quality control. Published by Elsevier Ltd. Keywords

Illinois at Chicago, University of

318

Running time variability and resource allocation : a data-driven analysis of high-frequency bus operations  

E-Print Network [OSTI]

Running time variability is one of the most important factors determining service quality and operating cost of high-frequency bus transit. This research aims to improve performance analysis tools currently used in the bus ...

Sánchez-Martínez, Gabriel Eduardo

2013-01-01T23:59:59.000Z

319

Simulation studies of bus electrode effect on discharge and luminous characteristics of plasma display panels  

SciTech Connect (OSTI)

We have investigated how bus electrodes affect discharge and luminous characteristics of a discharge cell. Three-dimensional simulations have been performed in a coplanar structured alternating current plasma display panel cell, with phosphor saturation effect taken into account. There exists the optimal position of bus electrodes for high luminance and luminous efficiency. Considering bus electrode thickness, we have found that in-bus structure is a promising candidate for high luminance, high luminous efficiency, and fast operation plasma display panels. Our simulation results would be very useful to understand the influence of bus electrode on characteristics of a plasma display panel cell, and would also provide a general guidance to improve its display performances.

Lee, Insook; Choi, K.Y. [Digital Display Research Laboratory, LG Electronics Inc., 16 Woomyeon-Dong, Seocho-Gu, Seoul 137-724 (Korea, Republic of)

2005-03-01T23:59:59.000Z

320

SunLine Transit Agency Advanced Technology Fuel Cell Bus Evaluation: Second Results Report and Appendices  

SciTech Connect (OSTI)

This report describes operations at SunLine Transit Agency for their newest prototype fuel cell bus and five compressed natural gas (CNG) buses. In May 2010, SunLine began operating its sixth-generation hydrogen fueled bus, an Advanced Technology (AT) fuel cell bus that incorporates the latest design improvements to reduce weight and increase reliability and performance. The agency is collaborating with the U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to evaluate the bus in revenue service. This is the second results report for the AT fuel cell bus since it was placed in service, and it focuses on the newest data analysis and lessons learned since the previous report. The appendices, referenced in the main report, provide the full background for the evaluation. They will be updated as new information is collected but will contain the original background material from the first report.

Eudy, L.; Chandler, K.

2011-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Simulation of the Post-Retrofit Thermal Energy Use for the Perry-Castaneda Library Building with the Use of Simplified System Models  

E-Print Network [OSTI]

. One method of determining the energy savings resulting from energy conserving retrofits relies on the use of a model for the daily whole building consumption, Epre, in the pre-retrofit configuration. Epre is typically a function of primary influencing...

Katipamula, S.; Claridge, D. E.

1991-01-01T23:59:59.000Z

322

Carbon capture retrofits and the cost of regulatory uncertainty  

SciTech Connect (OSTI)

Power generation firms confront impending replacement of an aging coal-fired fleet in a business environment characterized by volatile natural gas prices and uncertain carbon regulation. We develop a stochastic dynamic programming model of firm investment decisions that minimizes the expected present value of future power generation costs under uncertain natural gas and carbon prices. We explore the implications of regulatory uncertainty on generation technology choice and the optimal timing of investment, and assess the implications of these choices for regulators. We find that interaction of regulatory uncertainty with irreversible investment always raises the social cost of carbon abatement. Further, the social cost of regulatory uncertainty is strongly dependent on the relative competitiveness of IGCC plants, for which the cost of later carbon capture retrofits is comparatively small, and on the firm's ability to use investments in natural gas generation as a transitional strategy to manage carbon regulation uncertainty. Without highly competitive IGCC or low gas prices, regulatory uncertainty can increase the expected social cost of reducing emissions by 40 to 60%.

Reinelt, P.S.; Keith, D.W. [SUNY College of Fredonia, Fredonia, NY (United States). Dept. of Economics

2007-07-01T23:59:59.000Z

323

Public Housing: A Tailored Approach to Energy Retrofits  

SciTech Connect (OSTI)

Over one million HUD-supported public housing units provide rental housing for eligible low-income families across the country. A survey of over 100 PHAs across the country indicated that there is a high level of interest in developing low cost solutions that improve energy efficiency and can be seamlessly included in the refurbishment process. Further, PHAs, have incentives (both internal and external) to reduce utility bills. ARIES worked with two public housing authorities (PHAs) to develop packages of energy efficiency retrofit measures the PHAs can cost effectively implement with their own staffs in the normal course of housing operations at the time when units are refurbished between occupancies. The energy efficiency turnover protocols emphasized air infiltration reduction, duct sealing and measures that improve equipment efficiency. ARIES documented implementation in ten housing units. Reductions in average air leakage were 16-20% and duct leakage reductions averaged 38%. Total source energy consumption savings was estimated at 6-10% based on BEopt modeling with a simple payback of 1.7 to 2.2 years. Implementation challenges were encountered mainly related to required operational changes and budgetary constraints. Nevertheless, simple measures can feasibly be accomplished by PHA staff at low or no cost. At typical housing unit turnover rates, these measures could impact hundreds of thousands of unit per year nationally.

Dentz, J.; Conlin, F.; Podorson, D.; Alaigh, K.

2014-06-01T23:59:59.000Z

324

Highly Efficient Small Form Factor LED Retrofit Lamp  

SciTech Connect (OSTI)

This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent power quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.

Steven Allen; Fred Palmer; Ming Li

2011-09-11T23:59:59.000Z

325

Construction and startup experience for Milliken FGD Retrofit Project  

SciTech Connect (OSTI)

Under Round 4 of the U.S. Department of Energy`s Clean Coal Technology program, New York State Electric & Gas Corp. (NYSEG), in partnership with Saarbereg-Stebbins Engineering and Manufacturing Company, has retrofitted a formic acid enhanced forced oxidation wet limestone scrubber on Units 1 & 2 at the Milliken Steam Electric Station. Units 1 & 2 are 1950`s vintage Combustion Engineering tangentially fired pulverized coal units which are rated at nominal 150 MW each and operate in balanced draft mode. The FGD system for Unit 2 was placed into operation in January 1995 and the Unit 1 system in June, 1995. The project incorporates several unique aspects including low pH operation, a ceramic tile-lined cocurrent/countercurrent, split module absorber, a wet stack supported on the roof of the FGD building, and closed loop, zero liquid discharge operation producing commercial grade gypsum, and calcium chloride brine. The project objectives include 98% SO{sub 2} removal efficiency while burning high sulfur coal, the production of marketable byproducts to minimize solid waste disposal, zero wastewater discharge and space-saving design. The paper provides a brief overview of the project design, discusses construction and startup issues and presents early operating results. Process capital cost and economics of this design, procure and construct approach are reviewed relative to competing technologies.

Harvilla, J.; Mahlmeister, M. [New York State Electric and Gas Corp., Binghamton, NY (United States); Buchanan, T.; Jackson, C. [Parsons Power Group, Inc., Reading, PA (United States); Watts, J. [USDOE, Pittsburgh Energy Technology Center, PA (United States)

1996-12-01T23:59:59.000Z

326

Bay Ridge Gardens - Mixed-Humid Affordable Multifamily Housing Deep Energy Retrofit  

SciTech Connect (OSTI)

Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a 'base scope' retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a 'DER scope' which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

Lyons, J.; Moore, M.; Thompson, M.

2013-08-01T23:59:59.000Z

327

Energy Impacts of Energy and Indoor Environmental Quality Retrofits of Apartments in California  

SciTech Connect (OSTI)

Monthly gas and electricity use data from a set of 13 study apartments and 20 control apartments from three apartment buildings (B1 B3) in California were analyzed. The study apartments were retrofit with simultaneous energy savings and indoor environmental quality (IEQ) improvements as the goal. The control apartments were not retrofit. Pre-retrofit modeling indicated annual energy savings of 21percent, 17percent, and 27percent for the study apartments in B1-B3, respectively. Based on a comparison of changes in energy use of study apartments to energy use changes of control apartments, total measured savings of gas energy plus site electrical energy were 28percent in B1, 5percent in B2, and 3percent in B3. Given the small number of study apartments and the substantial changes in energy use within control apartments, the project yielded no conclusive evidence of energy savings. Apartment energy use increased with number of occupants and with floor area; however, the association with occupancy was most evident. Climate differences did not appear to be the major driver for the variability in energy use among apartments. Changes in occupant behaviors affecting energy use may have overwhelmed and obscured the energy savings in this small number of buildings. Much larger prior studies employing similar retrofits indicate that the retrofits usually do save energy.

Fisk, William J.; Norris, Federico; Singer, Brett C.

2013-11-01T23:59:59.000Z

328

Measuring energy-saving retrofits: Experiences from the Texas LoanSTAR program  

SciTech Connect (OSTI)

In 1988 the Governor`s Energy Management Center of Texas received approval from the US Department of Energy to establish a $98.6 million state-wide retrofit demonstration revolving loan program to fund energy-conserving retrofits in state, public school, and local government buildings. As part of this program, a first-of-its-kind, statewide Monitoring and Analysis Program (MAP) was established to verify energy and dollar savings of the retrofits, reduce energy costs by identifying operational and maintenance improvements, improve retrofit selection in future rounds of the LoanSTAR program, and initiate a data base of energy use in institutional and commercial buildings located in Texas. This report discusses the LoanSTAR MAP with an emphasis on the process of acquiring and analyzing data to measure savings from energy conservation retrofits when budgets are a constraint. This report includes a discussion of the program structure, basic measurement techniques, data archiving and handling, data reporting and analysis, and includes selected examples from LoanSTAR agencies. A summary of the program results for the first two years of monitoring is also included.

Haberl, J.S.; Reddy, T.A.; Claridge, D.E.; Turner, W.D.; O`Neal, D.L.; Heffington, W.M. [Texas A and M Univ., College Station, TX (United States). Energy Systems Lab.] [Texas A and M Univ., College Station, TX (United States). Energy Systems Lab.

1996-02-01T23:59:59.000Z

329

High efficacy plasma display panel with vertically raised bus electrodes  

SciTech Connect (OSTI)

The authors propose a high efficacy alternating current plasma display panel utilizing vertically raised multilayer bus electrodes. The cell structure was designed to provide an opposite discharge mode and low discharge current in a relatively long gap. The test panels having discharge gaps of 330, 350, and 370 {mu}m were fabricated and basic properties of the panel were investigated in terms of current-voltage characteristics, luminance, and luminous efficiency. The cells with proposed structure show higher luminance and lower current simultaneously. The improvement in luminous efficiency is found to be a factor of 2 compared with the conventional coplanar structure having an electrode gap of 60 {mu}m. Emission spectra and spatio-temporal distribution of infrared light in discharge were measured. It is shown that high luminous efficiency of proposed cell originates from high excitation efficiency, low surface loss of charged particles, and enlarged discharge volume.

Ok, Jung-Woo; Lee, Hae June; Kim, Dong-Hyun; Park, Chung-Hoo; Lee, Ho-Jun; Kim, Jae-Sung; Choi, Kwang-Yeol [Department of Electrical Engineering, Pusan National University, Geumjeong-gu, Busan 609-735 (Korea, Republic of); PDP R and D Department, PDP Division, LG Electronics Inc., Gumi 730-030 (Korea, Republic of); Digital Display Research Laboratory, LG Electronics Inc., Seoul 137-724 (Korea, Republic of)

2006-10-30T23:59:59.000Z

330

Evaluating an Exterior Insulation and Finish System for Deep Energy Retrofits  

SciTech Connect (OSTI)

Exterior insulation and finish systems (EIFS) are proprietary synthetic formulations that are applied to the exterior walls of buildings to serve as insulation and exterior cladding. The insulation thickness can vary from less than one inch to a foot or more. In this project the applicability of EIFS for residential deep energy retrofits was investigated through modeling and a case study home. The home was retrofitted using a site-applied four-inch-thick EIFS. Site-specific details were developed as required for the residential retrofit application. Site work and the costs of the EIFS system were documented. The demonstration home was modeled using Building Energy Optimization energy and cost analysis software to explore cost effectiveness of various EIFS insulation thicknesses in two climate locations.

Dentz, J.; Podorson, D.

2014-01-01T23:59:59.000Z

331

Retrofit of Soederberg smelter at Alusaf Bayside plant. Part 1: Conceptual design and engineering  

SciTech Connect (OSTI)

A main objective of the Bayside Smelter modernization at Alusaf Pty. is the retrofit of the Soederberg pots operating at 120 kA to prebake cells with a current load of 165 kA. The complete design and engineering of this modernization project was done by VAW. Based on computer simulations a tailor-made concept for the retrofit project was developed. A pilot plant trial was conducted successfully in 1994. This paper presents the retrofit concept with details of the magneto-hydrodynamic and thermo-electric calculations. Plant measurements demonstrate the good agreement with computer simulations. Some highlights of the detailed engineering for the modernized pots elucidate concepts of integrating existing and new hardware.

Vogelsang, D.; Droste, C.; Segatz, M.; Eick, I. [VAW Aluminium-Technologie GmbH, Bonn (Germany)

1996-10-01T23:59:59.000Z

332

Retrofit Audits and Cost Estimates: A Look at Quality and Consistency  

SciTech Connect (OSTI)

Retrofit NYC Block by Block is an outreach program targeting owners of one- to four-family homes, the most common building type in New York City, with more than 600,000 structures citywide. Administered by the Pratt Center for Community Development and implemented by four nonprofit, community based organizations, Block by Block connects residents, businesses, and religious and civic organizations in predominantly low- and moderate-income neighborhoods with one or more of a half-dozen public and private financial incentive programs that facilitate energy-efficiency retrofits. This research project sought to evaluate the approach, effectiveness, and the energy use reductions accomplished by the Retrofit NYC: Block by Block program.

Eisenberg, L.; Shapiro, C.; Fleischer, W.

2012-10-01T23:59:59.000Z

333

Strategy Guideline: Energy Retrofits for Low-Rise Multifamily Buildings in Cold Climates  

SciTech Connect (OSTI)

This Strategy Guideline explains the benefits of evaluating and identifying energy efficiency retrofit measures that could be made during renovation and maintenance of multifamily buildings. It focuses on low-rise multifamily structures (three or fewer stories) in a cold climate. These benefits lie primarily in reduced energy use, lower operating and maintenance costs, improved durability of the structure, and increased occupant comfort. This guideline focuses on retrofit measures for roof repair or replacement, exterior wall repair or gut rehab, and eating system maintenance. All buildings are assumed to have a flat ceiling and a trussed roof, wood- or steel-framed exterior walls, and one or more single or staged boilers. Estimated energy savings realized from the retrofits will vary, depending on the size and condition of the building, the extent of efficiency improvements, the efficiency of the heating equipment, the cost and type of fuel, and the climate location.

Frozyna, K.; Badger, L.

2013-04-01T23:59:59.000Z

334

Diesel plant retrofitting options to enhance decentralized electricity supply in Indonesia  

SciTech Connect (OSTI)

Over the last 20 years, the government of Indonesia has undertaken an extensive program to provide electricity to the population of that country. The electrification of rural areas has been partially achieved through the use of isolated diesel systems, which account for about 20% of the country`s generated electricity. Due to many factors related to inefficient power production with diesels, the National Renewable Energy Laboratory, in conjunction with PLN, the Indonesian national utility, Community Power Corporation, and Idaho Power Company, analyzed options for retrofitting existing diesel power systems. This study considered the use of different combinations of advanced diesel control, the addition of wind generators, photovoltaics and batteries to reduce the systems of overall cost and fuel consumption. This analysis resulted in a general methodology for retrofitting diesel power systems. This paper discusses five different retrofitting options to improve the performance of diesel power systems. The systems considered in the Indonesian analysis are cited as examples for the options discussed.

Baring-Gould, E.I.; Barley, C.D.; Drouilhet, S. [and others] [and others

1997-09-01T23:59:59.000Z

335

Short-term measurements for the determination of envelope retrofit performance  

SciTech Connect (OSTI)

Short-term monitoring for estimating thermal parameters of a building, along with an analytical technique to (1) determine the long-term performance and (2) calculate the parameters from a building description, has many valuable applications, which include energy ratings, diagnostics, and retrofit analysis. In this paper we address issues relating to reducing uncertainties in estimating thermal parameters with emphasis on retrofit applications. In general, it is necessary to impose a known heat flow with a suitable profile to reliably estimate the parameters. This is demonstrated with test cell measurements taken before and after changes were made to the test cell. The eventual goal of this project is to develop a practical methodology to determine long-term retrofit performance from short-term tests.

Subbarao, K.; Mort, D.; Burch, J.

1985-06-01T23:59:59.000Z

336

Connecticut Transit (CTTRANSIT) Fuel Cell Transit Bus: Third Evaluation Report and Appendices  

Broader source: Energy.gov [DOE]

This report describes operations at Connecticut Transit (CTTRANSIT) in Hartford for one prototype fuel cell bus and three new diesel buses operating from the same location. The prototype fuel cell bus was manufactured by Van Hool and ISE Corp. and features an electric hybrid drive system with a UTC Power PureMotion 120 Fuel Cell Power System and ZEBRA batteries for energy storage. The fuel cell bus started operation in April 2007, and evaluation results through October 2009 are provided in this report.

337

Connecticut Transit (CTTRANSIT) Fuel Cell Transit Bus: Third Evaluation Report and Appendices  

SciTech Connect (OSTI)

This report describes operations at Connecticut Transit (CTTRANSIT) in Hartford for one prototype fuel cell bus and three new diesel buses operating from the same location. The prototype fuel cell bus was manufactured by Van Hool and ISE Corp. and features an electric hybrid drive system with a UTC Power PureMotion 120 Fuel Cell Power System and ZEBRA batteries for energy storage. The fuel cell bus started operation in April 2007, and evaluation results through October 2009 are provided in this report.

Chandler, K.; Eudy, L.

2010-01-01T23:59:59.000Z

338

The evaluation of a 4000-home geothermal heat pump retrofit at Fort Polk, Louisiana: Final Report  

SciTech Connect (OSTI)

This report documents an independent evaluation of an energy retrofit of 4,003 family housing units at Fort Polk, Louisiana, under an energy savings performance contract (ESPC). Replacement of the heating, cooling, and water heating systems in these housing units with geothermal heat pumps (GHPs) anchored the retrofit; low-flow shower heads and compact fluorescent lighting were also installed, as well as attic insulation where needed. Statistically valid findings indicate that the project will save 25.8 million kWh, or 32.5% of the pre-retrofit whole-community electrical consumption, and 100% of the whole-community natural gas previously used for space conditioning and water heating (260,000 therms) in a typical meteorological year. At the end-use level, the GHPs were found to save about 42% of the pre-retrofit electrical consumption for heating, cooling, and water heating in housing units that were all-electric in the pre-retrofit period. This report also demonstrates an improved method of predicting energy savings. Using an engineering model calibrated to pre-retrofit energy use data collected in the field, the method predicted actual energy savings on one of the electric feeders at Fort Polk with a very high degree of accuracy. The accuracy of this model was in turn dependent on data-calibrated models of the geothermal heat pump and ground heat exchanger that are described in this report. In addition this report documents the status of vertical borehole ground heat exchanger (BHEx) design methods at the time this project was designed, and demonstrates methods of using data collected from operating GHP systems to benchmark BHEx design methods against a detailed engineering model calibrated to date. The authors also discuss the ESPC`s structure and implementation and how the experience gained here can contribute to the success of future ESPCs.

Hughes, P.J.; Shonder, J.A.

1998-03-01T23:59:59.000Z

339

Data and Analytics to Inform Energy Retrofit of High Performance Buildings  

SciTech Connect (OSTI)

Buildings consume more than one-third of the world?s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis ? energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high performance building in California to analyze its energy use and identify retrofit opportunities, including: (1) analyzing patterns of major energy end-use categories at various time scales, (2) benchmarking the whole building total energy use as well as major end-uses against its peers, (3) benchmarking the power usage effectiveness for the data center, which is the largest electricity consumer in this building, and (4) diagnosing HVAC equipment using detailed time-series operating data. Finally, a few energy efficiency measures were identified for retrofit, and their energy savings were estimated to be 20percent of the whole-building electricity consumption. Based on the analyses, the building manager took a few steps to improve the operation of fans, chillers, and data centers, which will lead to actual energy savings. This study demonstrated that there are energy retrofit opportunities for high performance buildings and detailed measured building performance data and analytics can help identify and estimate energy savings and to inform the decision making during the retrofit process. Challenges of data collection and analytics were also discussed to shape best practice of retrofitting high performance buildings.

Hong , Tianzhen; Yang, Le; Hill, David; Feng , Wei

2014-01-25T23:59:59.000Z

340

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance; Grocery Stores (Revised) (Book)  

SciTech Connect (OSTI)

The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders successfully plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited in these guides. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. Grocery stores were selected as one of the highest priority sectors, because they represent one of the most energy-intensive market segments.

Hendron, B.

2013-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)  

SciTech Connect (OSTI)

The U.S. Department of Energy developed the K-12 Advanced Energy Retrofit Guide to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. We emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluation of the most promising retrofit measure for each building type. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings.

Not Available

2013-02-01T23:59:59.000Z

342

Vehicle Technologies Office Merit Review 2014: High Performance DC Bus Film Capacitor  

Broader source: Energy.gov [DOE]

Presentation given by GE Global Research at 2014 DOE Hydrogen and Fuel Cells Program and Vehicle Technologies Office Annual Merit Review and Peer Evaluation Meeting about high performance DC bus...

343

Simulating service reliability of a high frequency bus route using automatically collected data  

E-Print Network [OSTI]

High frequency bus routes are subject to a variety of influences that can affect the quality of service provided to passengers. Since they have short headways and high passenger demand interaction between buses can easily ...

Milkovits, Martin Nicholas

2008-01-01T23:59:59.000Z

344

SunLine Transit Agency Fuel Cell Transit Bus: Fifth Evaluation...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

operations at SunLine Transit Agency for a prototype fuel cell bus and five compressed natural gas (CNG) buses. This is the fifth evaluation report for this site, and it...

345

E-Print Network 3.0 - air school bus Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Study Abroad Course Equivalency Database Summary: EnglandLondon School of Economics & Political SciencePrinciples of AccountingACC 311 LondonBUS Spain... Suffolk University-Madrid...

346

Leveraging infrastructure : sustainable bus rapid transit route planning in Beirut, Lebanon  

E-Print Network [OSTI]

This thesis applies the concepts of urban design, public transportation planning, economic development, and sustainability, to the routing and site plan of a two-kilometer bus rapid transit (BRT) line segment into downtown ...

Nabti, Jumana M., 1976-

2004-01-01T23:59:59.000Z

347

SunLine Test Drives Hydrogen Bus: Hydrogen Fuel Cell & Infrastructure...  

Broader source: Energy.gov (indexed) [DOE]

is able to cover 11 miles on an energy equivalent gallon of hydrogen, nearly triple the fuel economy of a 30-foot conven- tional bus. It accommodates up to 26 riders and has a...

348

SunLine Expands Horizons with Fuel Cell Bus Demo. Hydrogen, Fuel...  

Broader source: Energy.gov (indexed) [DOE]

SunLine. NRELPIX 14396 NRELPIX 14395 FUEL CELL BUS DEMONSTRATION PROJECTS Hydrogen, Fuel Cells & Infrastructure Technologies program F U E L C E L L B U S D E M o N S T R A T I...

349

Cold Climate Foundation Retrofit Energy Savings: The Simulated Energy and Experimental Hygrothermal Performance of Cold Climate Foundation Wall Insulation Retrofit Measures -- Phase I, Energy Simulation  

SciTech Connect (OSTI)

A split simulation whole building energy/3-dimensional earth contact model (termed the BUFETS/EnergyPlus Model or BEM) capable of modeling the full range of foundation systems found in the target retrofit housing stock has been extensively tested. These foundation systems that include abovegrade foundation walls, diabatic floors or slabs as well as lookout or walkout walls, currently cannot be modeled within BEopt.

Goldberg, L. F.; Steigauf, B.

2013-04-01T23:59:59.000Z

350

Data collection plan for Phase 2 Alternative Fuels Bus Data Collection Program. Final report  

SciTech Connect (OSTI)

This document constitutes the plan for collecting and reporting data associated with a special set of transit bus demonstrations to be conducted under the Urban Bus Program of the Alternative Motor Fuels Act (AMFA) of 1988. This program, called the Phase 2 Bus Data Collection Program, serves as an adjunct to the Phase I Bus Data Collection Program, collecting detailed data on just a few buses to augment and enhance the Phase 1 data in fulfilling the urban bus requirements of AMFA. Demonstrations will be conducted at a few transit system locations throughout the US and will use alternative fuels and associated technologies to reduce undesirable transit bus exhaust emissions. Several organizations will be involved in the data collection; NREL will manage the program, analyze and store vehicle data, and make these data available through the Alternative Fuels Data Center. This information will enable transit agencies, equipment manufacturers, fuel suppliers, and government policy makers to make informed decisions about buying and using alternative fuels.

Krenelka, T. [Battelle Columbus Labs., OH (United States)] [Battelle Columbus Labs., OH (United States)

1993-07-01T23:59:59.000Z

351

FRP Retrofit of the Ring-Beam of a Nuclear Reactor Containment Structure  

E-Print Network [OSTI]

SP·215-18 FRP Retrofit of the Ring-Beam of a Nuclear Reactor Containment Structure by M. Demers. A for the storage of the moderately contaminated nuclear reactor. The enforcement of more rigorous environmental. 1. HISTORY 1.1 Decommissioning of the Reactor The Gentilly-I nuclear power plant, located

352

ENERGY IMPACTS OF ENERGY AND INDOOR ENVIRONMENTAL QUALITY RETROFITS OF APARTMENTS IN CALIFORNIA  

E-Print Network [OSTI]

with simultaneous energy savings and indoor environmental quality (IEQ) improvements as the goal. The control apartments to energy use changes of control apartments, total measured savings of gas energy plus site1 ENERGY IMPACTS OF ENERGY AND INDOOR ENVIRONMENTAL QUALITY RETROFITS OF APARTMENTS IN CALIFORNIA

353

Advanced Energy Retrofit Guide (AERG): Practical Ways to Improve Energy Performance; Healthcare Facilities (Book)  

SciTech Connect (OSTI)

The Advanced Energy Retrofit Guide for Healthcare Facilities is part of a series of retrofit guides commissioned by the U.S. Department of Energy. By presenting general project planning guidance as well as detailed descriptions and financial payback metrics for the most important and relevant energy efficiency measures (EEMs), the guides provide a practical roadmap for effectively planning and implementing performance improvements in existing buildings. The Advanced Energy Retrofit Guides (AERGs) are intended to address key segments of the U.S. commercial building stock: retail stores, office buildings, K-12 schools, grocery stores, and healthcare facilities. The guides' general project planning considerations are applicable nationwide; the energy and cost savings estimates for recommended EEMs were developed based on energy simulations and cost estimates for an example hospital tailored to five distinct climate regions. These results can be extrapolated to other U.S. climate zones. Analysis is presented for individual EEMs, and for packages of recommended EEMs for two project types: existing building commissioning projects that apply low-cost and no-cost measures, and whole-building retrofits involving more capital-intensive measures.

Hendron, R.; Leach, M.; Bonnema, E.; Shekhar, D.; Pless, S.

2013-09-01T23:59:59.000Z

354

Data and analytics to inform energy retrofit of high performance Tianzhen Hong a,  

E-Print Network [OSTI]

National Laboratory, 1 Cyclotron Road, Berkeley, CA 94720, USA b Tsinghua University, Beijing 100084, China c Jones Lang Lassale, 100 Waterfront Place, West Sacramento, CA 95605, USA h i g h l i g h t s High, and diagnostics. The case study shows 20% of electricity can be saved by retrofit. a r t i c l e i n f o Article

355

The Caw Burn SUDS: performance of a settlement pond/wetland SUDS retrofit Kate Heal1*  

E-Print Network [OSTI]

) to remediate pollution of the Caw Burn by runoff from the Houston Industrial Estate, Livingston, Scotland-study of a retrofit SUDS constructed in 1996 to remediate pollution in the Caw Burn originating in runoff from runoff from the Houston Industrial Estate, where construction commenced in the 1960s, and two residential

Heal, Kate

356

YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems (Extended Version)  

E-Print Network [OSTI]

YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems (Extended Version security, and yet incurs minimal end-to-end communication latency. Keywords: SCADA network security, bump links between devices in legacy Supervisory Con- trol And Data Acquisition (SCADA) systems, on which

357

YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems  

E-Print Network [OSTI]

YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems Patrick P. Tsang in Supervisory Control And Data Acquisition (SCADA) systems. Previous BITW solutions fail to provide minimal end-to-end communication latency. A microcontroller prototype of our solution is under development

358

YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems  

E-Print Network [OSTI]

YASIR: A Low-Latency, High-Integrity Security Retrofit for Legacy SCADA Systems Patrick P. Tsang-to-end communication latency. 1 Introduction 1.1 SCADA Systems Supervisory Control And Data Acquisition (SCADA) systems Supervisory Control And Data Acquisition (SCADA) systems, on which the proper operations of critical

Smith, Sean W.

359

Edinburgh Research Explorer Modelling Urban scale Retrofit, Pathways to 2050 Low Carbon  

E-Print Network [OSTI]

electricity consumption in Wales with power generated from renewable sources by 2025 (WAG, 2009) which would to engage with the modelling process. INTRODUCTION The UK government has set an ambitious target of 80 retrofit design process need to be researched further. The Welsh Government have committed to achieving

Millar, Andrew J.

360

FLASTAR: Measured Savings of a Comprehensive Energy Retrofit in a Florida Elementary School  

E-Print Network [OSTI]

.000 square foot facility was approximately 775,000 kWh (60 kBtu/ft^2) or $55,200 in the base year (1994). During the summer of 1995, replacement of aging chillers resulted in 30% reduction to cooling energy use. The second retrofit was occupancy sensor...

Sherwin, J. R.; Parker, D. S.

1998-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

RETROFIT: A SOFTWARE TO SOLVE OPTIMIZATION AND IDENTIFICATION PROBLEMS APPLIED TO BUILDING ENERGY  

E-Print Network [OSTI]

under forecast weather or use conditions. Demand response strategies in smart grids consist in adjusting- els. ReTrofiT is first of all a simulation tool for evaluating building thermal behaviour can be obtained if the internal parameters of the model are calibrated using on-site measurements

Boyer, Edmond

362

Sustainable wall construction and exterior insulation retrofit technology process and structure  

DOE Patents [OSTI]

A low-cost process for exterior wall insulation retrofit, or new wall construction by stacking layers of fabric tube filled with insulating material against a wall and covering them with mesh and stucco provides a durable structure with good insulating value.

Vohra, Arun (Bethesda, MD)

2000-01-01T23:59:59.000Z

363

Energy Conservation in Multifamily Housing: Review and Recommendations for Retrofit Programs  

E-Print Network [OSTI]

Energy Conservation in Multifamily Housing: Review and Recommendations for Retrofit Programs John identified as a particularly challenging area for energy conservation efforts. Much work has been done as a book on multifamily energy conservation. Here we preview key results from that project, with a focus

Diamond, Richard

364

Starting a local conservation and passive solar retrofit program: an energy planning sourcebook  

SciTech Connect (OSTI)

A city planner or a neighborhood activist may wish to initiate a local conservation and passive solar retrofit program but may not have previous experience in doing so. This sourcebook is designed to assist interested individuals with their energy planning efforts, from determining retrofit potential, to financing and implementing the program. An approach or methodology is provided which can be applied to determine retrofit potential in single-family residences, mobile homes, multifamily residences, and nonresidential buildings. Case studies in Albuquerque, New Mexico, are given as examples. Guidelines are provided for evaluating the economic benefits of a retrofit program through benefit-cost analysis and economic base studies at the city and neighborhood levels. Also included are approaches to community outreach, detailing how to get started, how to gain local support, and examples of successful programs throughout the US. The need for financing, the development of a local strategy, public and private financing techniques, and community energy service organizations are examined. In addition to the Albuquerque case studies, a brief technology characterization, heat-loss calculations, economic tools, and a list of resources are appended.

Barber, V; Mathews, R

1982-02-01T23:59:59.000Z

365

Light-RITE California The Lighting Retrofit Information, Training and Education program  

E-Print Network [OSTI]

to implementing best practices in California's public buildings Professor Michael Siminovitch (co-author with UC, CSC, CCC, CIEE, DGS) UC Davis Rosenfeld Chair in Energy Efficiency The Consortium of Public Building makers on the implementation of best practices for lighting retrofits. We need to quickly develop

California at Davis, University of

366

Review of selected recent research on US seismic design and retrofit  

E-Print Network [OSTI]

at Buffalo, Buffalo, NY, USA 2 University of Texas Austin, Department of Civil Engineering, Austin, TX, USA 3 on research on retrofit of beam-to-column moment connections, frame modifications at beams' mid- span, self-centering systems, zipper frames, buckling-restrained braced frames, steel plate shear walls, plastic and rotation

Bruneau, Michel

367

Development of Cost Effective Oxy-Combustion Retrofitting for Coal-Fired Boilers  

SciTech Connect (OSTI)

The overall objective of this project is to further develop the oxy-combustion technology for commercial retrofit in existing wall-fired and Cyclone boilers by 2012. To meet this goal, a research project was conducted that included pilot-scale testing and a full-scale engineering and economic analysis.

Hamid Farzan

2010-12-31T23:59:59.000Z

368

Review of Existing Energy Retrofit Sang Hoon Lee, Tianzhen Hong, Mary Ann Piette  

E-Print Network [OSTI]

ERNEST ORLANDO LAWRENCE BERKELEY NATIONAL LABORATORY #12;Disclaimer This document was prepared Orlando Lawrence Berkeley National Laboratory is an equal opportunity employer. Please cite this report as follows: Lee, S.H., Hong, T., Piette, M.A. Review of existing energy retrofit tools. Lawrence Berkeley

369

Byggmeister Test Home: Cold Climate Multifamily Masonry Building Condition Assessment and Retrofit Analysis  

SciTech Connect (OSTI)

This report describes a retrofit project undertaken by Building Science Corporation and partner Byggmeister on a multifamily brick row house located in Jamaica Plain, MA. This project studied the row house to determine the right combination of energy efficiency measures that are feasible, affordable, and suitable for this type of construction and acceptable to homeowners.

Wytrykowska, H.; Ueno, K.; Van Straaten, R.

2012-09-01T23:59:59.000Z

370

Actual and Estimated Energy Savings Comparison for Deep Energy Retrofits in the Pacific Northwest  

SciTech Connect (OSTI)

Seven homes from the Pacific Northwest were selected to evaluate the differences between estimated and actual energy savings achieved from deep energy retrofits. The energy savings resulting from these retrofits were estimated, using energy modeling software, to save at least 30% on a whole-house basis. The modeled pre-retrofit energy use was trued against monthly utility bills. After the retrofits were completed, each of the homes was extensively monitored, with the exception of one home which was monitored pre-retrofit. This work is being conducted by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy Building Technologies Program as part of the Building America Program. This work found many discrepancies between actual and estimated energy savings and identified the potential causes for the discrepancies. The differences between actual energy use and modeled energy use also suggest improvements to improve model accuracy. The difference between monthly whole-house actual and estimated energy savings ranged from 75% more energy saved than predicted by the model to 16% less energy saved for all the monitored homes. Similarly, the annual energy savings difference was between 36% and -14%, which was estimated based on existing monitored savings because an entire year of data is not available. Thus, on average, for all six monitored homes the actual energy use is consistently less than estimates, indicating home owners are saving more energy than estimated. The average estimated savings for the eight month monitoring period is 43%, compared to an estimated savings average of 31%. Though this average difference is only 12%, the range of inaccuracies found for specific end-uses is far greater and are the values used to directly estimate energy savings from specific retrofits. Specifically, the monthly post-retrofit energy use differences for specific end-uses (i.e., heating, cooling, hot water, appliances, etc.) ranged from 131% under-predicted to 77% over-predicted by the model with respect to monitored energy use. Many of the discrepancies were associated with occupant behavior which influences energy use, dramatically in some cases, actual versus modeled weather differences, modeling input limitations, and complex homes that are difficult to model. The discrepancy between actual and estimated energy use indicates a need for better modeling tools and assumptions. Despite the best efforts of researchers, the estimated energy savings are too inaccurate to determine reliable paybacks for retrofit projects. While the monitored data allows researchers to understand why these differences exist, it is not cost effective to monitor each home with the level of detail presented here. Therefore an appropriate balance between modeling and monitoring must be determined for more widespread application in retrofit programs and the home performance industry. Recommendations to address these deficiencies include: (1) improved tuning process for pre-retrofit energy use, which currently utilized broad-based monthly utility bills; (2) developing simple occupant-based energy models that better address the many different occupant types and their impact on energy use; (3) incorporating actual weather inputs to increase accuracy of the tuning process, which uses utility bills from specific time period; and (4) developing simple, cost-effective monitoring solutions for improved model tuning.

Blanchard, Jeremy; Widder, Sarah H.; Giever, Elisabeth L.; Baechler, Michael C.

2012-10-01T23:59:59.000Z

371

Low NO sub x /SO sub x Burner retrofit for utility cyclone boilers  

SciTech Connect (OSTI)

The objective of this project is to demonstrate the LNS Burner as retrofitted to the host cyclone boiler for effective low-cost control of NO{sub x} and SO{sub x} emissions while firing a bituminous coal. The LNS Burner employs a simple, innovative combustion process to burn pulverized coal at high temperatures and provides effective, low-cost control of sulfur dioxide (SO{sub 2}) and nitrogen oxides (NO{sub x}) emissions. The coal ash contains sulfur and is removed in the form of molten slag and flyash. Cyclone-fired boiler units are typically older units firing high-sulfur bituminous coals at very high temperatures which results in very high NO{sub x} and SO{sub x} emissions. The addition of conventional emission control equipment, such as wet scrubbers, to these older cyclone units in order to meet current and future environmental regulations is generally not economic. Further, the units are generally not compatible with low sulfur coal switching for S0{sub 2} control or selective catalytic reduction technologies for NO{sub x} control. Because the LNS Burner operates at the same very high temperatures as a typical cyclone boiler and produces a similar slag product, it may offer a viable retrofit option for cyclone boiler emission control. This was confirmed by the Cyclone Boiler Retrofit Feasibility Study carried out by TransAlta and an Operating Committee formed of cyclone boiler owners in 1989. An existing utility cyclone boiler, was then selected for the evaluation of the cost and performance study. It was concluded that the LNS Burner retrofit would be a cost-effective option for control of cyclone boiler emissions. A full-scale demonstration of the LNS Burner retrofit was selected in October 1988 as part of the DOE's Clean Coal Technology Program Round II.

Not Available

1990-01-01T23:59:59.000Z

372

A new vehicle data bus architecture and IVIS evaluation platform for ITS modulus  

SciTech Connect (OSTI)

An increasing number of ITS-related after-market systems present a set of in-vehicle installation and use problems relatively unique in the history of automobile use. Many automobile manufacturers would like to offer these new state of the art devices to customers, but are hampered by the current design cycle of new cars. While auto manufacturers are indeed using multiplex buses (the automotive equivalent of a computer local area network), problems remain because manufacturers are not converging on a single bus standard. This paper presents a new dual-bus architecture to address these problems, with an In-Vehicle Information System (IVIS) research platform on which the principles embodied in the ITS Data Bus architecture can be evaluated. The dual-bus architecture has been embodied in a proposed SAE standard, with a ratification vote in December, 1996. The architecture and a reference model for the interfaces and protocols of the new bus are presented and described. The goals of the ITS Data Bus are to be inexpensive and easy to install, and to provide for safe and secure functioning. These high-level goals are embodied in the proposed standard. The IVIS Development Platform comprises a number of personal computers linked via ethernet LAN, with a high-end PC serving as the IVIS computer. In this LAN, actual devices can be inserted in place of the original PC which emulated them. This platform will serve as the development and test bed for an ITS Data Bus Conformity Test, the SAE standard for which has also been developed.

Spelt, P.F. [Oak Ridge National Lab., TN (United States); Kirson, A.M. [Motorola, Inc., Northbrook, IL (United States); Scott, S. [Jet Propulsion Lab., Washington, DC (United States)

1998-12-31T23:59:59.000Z

373

Research, development and demonstration of a fuel cell/battery powered bus system. Phase 1, Final report  

SciTech Connect (OSTI)

Purpose of the Phase I effort was to demonstrate feasibility of the fuel cell/battery system for powering a small bus (under 30 ft or 9 m) on an urban bus route. A brassboard powerplant was specified, designed, fabricated, and tested to demonstrate feasibility in the laboratory. The proof-of-concept bus, with a powerplant scaled up from the brassboard, will be demonstrated under Phase II.

NONE

1990-02-28T23:59:59.000Z

374

Retrofitting of Conditioning Systems for Existing Small Commercial Buildings - Analysis and Design of Liquid Desiccant - Vapor Compression Hybrid  

E-Print Network [OSTI]

and limitations of retrofit technology for these characteristic structures have been the focus of the experience gained through the design and installation of a system adapted to a building constructed in the early 1960's. The existing split package air...

Arnas, O. A.; McQueen, T. M.

1984-01-01T23:59:59.000Z

375

Predicting the potential for energy efficiency retrofits in single-family homes : an exploration of data targeting mechanisms  

E-Print Network [OSTI]

Historically, the lack of data on the United States' housing stock has been one of the primary barriers to market penetration of residential energy efficiency retrofits. Without knowledge of the homes and customers to ...

Goldstein, Kaitlin Ryan

2014-01-01T23:59:59.000Z

376

ApRemodel: A Study of Non-Technical Innovation in Multi- Occupancy Sustainable Retrofit Housing Projects  

E-Print Network [OSTI]

The ApRemodel project is a study of multi-occupancy retrofit in the Finnish context. As part of the study a research project was commissioned to identify and compare innovative practice with regards to non-technical issues being addressed in retrofit projects being undertaken in the UK housing sector. Given that the examples were required to address a multi-occupancy scenario all of these cases come from the UK social housing sector, where the majority of multi-occupancy retrofit is being undertaken. Here we outline the cases that were reviewed, the innovations that were identified within them and the main initial findings. Keywords: Retrofit, case studies, social housing, innovation

Will Swan; Carl Abbott; Catherine Barlow

377

Development of a Web-based Emissions Reduction Calculator for Retrofits to Municipal Water Supply and Waste Water Facilities  

E-Print Network [OSTI]

DEVELOPMENT OF A WEB-BASED EMISSIONS REDUCTION CALCULATOR FOR RETROFITS TO MUNICIPAL WATER SUPPLY AND WASTE WATER FACILITIES Juan-Carlos Baltazar Research Associate Zi Liu, Ph.D. Research Engineer Don R. Gilman, P.E. Senior Software... and used to calculate the electricity savings from potential retrofits to municipal water supply and waste water facilities. The methodology integrates the ASHRAE Inverse Model Toolkit (IMT) 1 used for weather normalization, a peak...

Baltazar-Cervantes, J. C.; Liu, Z.; Gilman, D.; Haberl, J. S.; Culp, C.

2005-01-01T23:59:59.000Z

378

Occupant-in-Place Energy Efficiency Retrofit in a Group Home for 30% Energy Savings in Climate Zone 4  

SciTech Connect (OSTI)

Energy efficiency retrofits (EERs) face many challenges on the path to scalability. Limited budgets, cost effectiveness, risk factors, and accessibility impact the type and the extent of measures that can be implemented feasibly to achieve energy savings goals. Group home retrofits can face additional challenges than those in single family homes - such as reduced access (occupant-in-place restrictions) and lack of incentives for occupant behavioral change. This project studies the specification, implementation, and energy savings from an EER in a group home, with an energy savings goal of 30%. This short term test report chronicles the retrofit measures specified, their projected cost-effectiveness using building energy simulations, and the short term test results that were used to characterize pre-retrofit and post-retrofit conditions. Additionally, the final report for the project will include analysis of pre- and post-retrofit performance data on whole building energy use, and an assessment of the energy impact of occupant interface with the building (i.e., window operation). Ultimately, the study's results will be used to identify cost effective EER measures that can be implemented in group homes, given constraints that are characteristic of these buildings. Results will also point towards opportunities for future energy savings.

Moore, M.

2013-08-01T23:59:59.000Z

379

Increasing throughput of multiplexed electrical bus in pipe-lined architecture  

DOE Patents [OSTI]

Techniques are disclosed for increasing the throughput of a multiplexed electrical bus by exploiting available pipeline stages of a computer or other system. For example, a method for increasing a throughput of an electrical bus that connects at least two devices in a system comprises introducing at least one signal hold stage in a signal-receiving one of the two devices, such that a maximum frequency at which the two devices are operated is not limited by a number of cycles of an operating frequency of the electrical bus needed for a signal to propagate from a signal-transmitting one of the two devices to the signal-receiving one of the two devices. Preferably, the signal hold stage introduced in the signal-receiving one of the two devices is a pipeline stage re-allocated from the signal-transmitting one of the two devices.

Asaad, Sameh; Brezzo, Bernard V; Kapur, Mohit

2014-05-27T23:59:59.000Z

380

Byggmeister Test Home: Analysis and Initial Results of Cold Climate Wood-Framed Home Retrofit  

SciTech Connect (OSTI)

BSC seeks to further the energy efficiency market for New England area retrofit projects by supporting projects that are based on solid building science fundamentals and verified implementation. With the high exposure of energy efficiency and retrofit terminology being used in the general media at this time, it is important to have evidence that measures being proposed will in fact benefit the homeowner through a combination of energy savings, improved durability, and occupant comfort. There are several basic areas of research to which the technical report for these test homes can be expected to contribute. These include the combination of measures that is feasible, affordable and acceptable to homeowners as well as expectations versus results. Two Byggmeister multi-family test homes in Massachusetts are examined with the goal of providing case studies that could be applied to other similar New England homes.

Gates, C.

2013-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Metering and Monitoring Approaches for Verifying Energy Savings from Energy Conservation Retrofits: Experiences from the Field  

E-Print Network [OSTI]

METERING AND MONITORING APPROACHES FOR VERIFYING ENERGY SAVINGS FROM ENERGY CONSERVATION RETROFITS: EXPERIENCES FROM THE FIELD John R. McBride Charles J. Bohmer Roger H. Lippman Senior Scientist Senior Instrumentation Senior Instrumentation... drying process that operates at a constant energy level on a constant schedule are examples of this class of load. Engineering calculations without in-field metering and monitoring may be sufficient for this project class. Next in complexity...

McBride, J. R.; Bohmer, C. J.; Lippman, R. H.

382

Retrofitting Inefficient Rooftop Air-Conditioning Units Reduces U.S. Navy Energy Use (Fact Sheet)  

SciTech Connect (OSTI)

As part of the U.S. Navy's overall energy strategy, the National Renewable Energy Laboratory (NREL) partnered with the Naval Facilities Engineering Command (NAVFAC) to demonstrate market-ready energy efficiency measures, renewable energy generation, and energy systems integration. One such technology - retrofitting rooftop air-conditioning units with an advanced rooftop control system - was identified as a promising source for reducing energy use and costs, and can contribute to increasing energy security.

Not Available

2014-04-01T23:59:59.000Z

383

Assessing the Energy Savings of Tankless Water Heater Retrofits in Public Housing  

SciTech Connect (OSTI)

This report describes the methodology, analysis, and findings from a case study of a 110 unit retrofit of gas tankless water heaters in a hot/humid climate in Alachua County, Florida. The housing units had their gas-fired tank type water heaters replaced with gas-fired tankless water heaters as part of a federal program that targeted reduced energy use in public housing.

Ries, R.; Walters, R.; Dwiantoro, D.

2013-01-01T23:59:59.000Z

384

CC® of Retrofitted, Renovated, and Rented Systems and Equipment in Utilities Plants  

E-Print Network [OSTI]

Chen David E. Claridge W. Dan Turner Song Deng Energy Systems Laboratory Texas A&M University System KEYWORD Continuous Commissioning, Functional Performance Testing, Chillers, Boilers, Heating Hot water System ABSTRACT It is a common practice..., including performance testing and evaluation on rental/retrofitted chillers and a renovated heating hot water system. INTRODUCTION The Energy Systems Laboratory (ESL) has been conducting CC to the Texas A&M University (TAMU), College Station, Texas...

Xu, C.; Chen, Q.; Claridge, D. E.; Turner, W. D.; Deng, S.

2005-01-01T23:59:59.000Z

385

Refinery Furnaces Retrofit with Gas Turbines Achieve Both Energy Savings and Emission Reductions  

E-Print Network [OSTI]

REFINERY FURNACES RETROFIT WITH GAS TURBINES ACHIEVE BOTH ENERGY SAVINGS AND EMISSION REDUCTIONS F. Giacobbe*, G. Iaquaniello**, R. G. Minet*, P. Pietrogrande* *KTI Corp., Research and Development Division, Monrovia, California **KTI Sp...A., Rome, Italy ABSTRACT Integrating gas turbines with refinery furnaces can be a cost effective means of reducing NO emissions while also generating electricity ~t an attractive heat rate. Design considerations and system costs are presented...

Giacobbe, F.; Iaquaniello, G.; Minet, R. G.; Pietrogrande, P.

386

Simulated Energy Savings Comparison Between Two Continuous Commissioning® Methods Applied to a Retrofitted Office Building  

E-Print Network [OSTI]

The 8 th International Conference for Enhanced Building Operations (ICEBO 2008) October 20-22, 2008, Berlin, Germany Simulated Energy Savings Comparison Between Two Continuous Commissioning ? Methods Applied to a Retrofitted Office Building... and the cold and hot 1 ESL-IC-08-10-30 Proceedings of the Eighth International Conference for Enhanced Building Operations, Berlin, Germany, October 20-22, 2008 The 8 th International Conference for Enhanced Building Operations (ICEBO 2008) October 20...

Texas A& M Campus Building CC® Team

387

DEMONSTRATION OF A FULL-SCALE RETROFIT OF THE ADVANCED HYBRID PARTICULATE COLLECTOR TECHNOLOGY  

SciTech Connect (OSTI)

The Advanced Hybrid Particulate Collector (AHPC), developed in cooperation between W.L. Gore & Associates and the Energy & Environmental Research Center (EERC), is an innovative approach to removing particulates from power plant flue gas. The AHPC combines the elements of a traditional baghouse and electrostatic precipitator (ESP) into one device to achieve increased particulate collection efficiency. As part of the Power Plant Improvement Initiative (PPII), this project was demonstrated under joint sponsorship from the U.S. Department of Energy and Otter Tail Power Company. The EERC is the patent holder for the technology, and W.L. Gore & Associates was the exclusive licensee for this project. The project objective was to demonstrate the improved particulate collection efficiency obtained by a full-scale retrofit of the AHPC to an existing electrostatic precipitator. The full-scale retrofit was installed on an electric power plant burning Powder River Basin (PRB) coal, Otter Tail Power Company's Big Stone Plant, in Big Stone City, South Dakota. The $13.4 million project was installed in October 2002. Project related testing concluded in December 2005. The following Final Technical Report has been prepared for the project entitled ''Demonstration of a Full-Scale Retrofit of the Advanced Hybrid Particulate Collector Technology'' as described in DOE Award No. DE-FC26-02NT41420. The report presents the operation and performance results of the system.

Tom Hrdlicka; William Swanson

2005-12-01T23:59:59.000Z

388

Techniques for Reducing Read Latency of Core Bus Wrappers Roman L. Lysecky, Frank Vahid, Tony D. Givargis  

E-Print Network [OSTI]

Techniques for Reducing Read Latency of Core Bus Wrappers Roman L. Lysecky, Frank Vahid, Tony D with their internal logic separated from their bus wrapper. This separation may introduce extra read latency. Pre. In this paper, we introduce a technique for automatically designing a pre-fetch unit that satisfies user

Vahid, Frank

389

Liquid balance monitoring inside conventional, Retrofit, and bio-reactor landfill cells  

SciTech Connect (OSTI)

Highlights: • The Retrofit, Control, and As-Built cells received 48, 14, and 213 L Mg{sup ?1} (liters of liquids per metric ton of waste). • The leachate collection system yielded 60, 57 and 198 L Mg{sup ?1} from the Retrofit, Control, and As-Built cells. • The head on liner in all cells was below regulatory limits. • Measured moisture content of the waste samples was consistent with that calculated from accumulated liquid by balance. • The in-place saturated hydraulic conductivity of the MSW was calculated to be in the range of 10{sup ?8} to 10{sup ?7} m s{sup ?1}. - Abstract: The Outer Loop landfill bioreactor (OLLB) in Louisville, KY, USA has been the site of a study to evaluate long-term bioreactor performance at a full-scale operational landfill. Three types of landfill units were studied including a conventional landfill (Control cell), a new landfill area that had an air addition and recirculation piping network installed as waste was being placed (As-Built cell), and a conventional landfill that was modified to allow for liquids recirculation (Retrofit cell). During the monitoring period, the Retrofit, Control, and As-Built cells received 48, 14, and 213 L Mg{sup ?1} (liters of liquids per metric ton of waste), respectively. The leachate collection system yielded 60, 57 and 198 L Mg{sup ?1} from the Retrofit, Control, and As-Built cells, respectively. The head on liner in all cells was below regulatory limits. In the Control and As-Built cells, leachate head on liner decreased once waste placement stopped. The measured moisture content of the waste samples was consistent with that calculated from the estimate of accumulated liquid by the liquid balance. Additionally, measurements on excavated solid waste samples revealed large spatial variability in waste moisture content. The degree of saturation in the Control cells decreased from 85% to 75%. The degree of saturation increased from 82% to 83% due to liquids addition in the Retrofit cells and decreased back to 80% once liquid addition stopped. In the As-Built cells, the degree of saturation increased from 87% to 97% during filling activities and then started to decrease soon after filling activities stopped to reach 92% at the end of the monitoring period. The measured leachate generation rates were used to estimate an in-place saturated hydraulic conductivity of the MSW in the range of 10{sup ?8} to 10{sup ?7} m s{sup ?1} which is lower than previous reports. In the Control and Retrofit cells, the net loss in liquids, 43 and 12 L Mg{sup ?1}, respectively, was similar to the measured settlement of 15% and 5–8% strain, respectively (Abichou et al., 2013). The increase in net liquid volume in the As-Built cells indicates that the 37% (average) measured settlement strain in these cells cannot be due to consolidation as the waste mass did not lose any moisture but rather suggests that settlement was attributable to lubrication of waste particle contacts, softening of flexible porous materials, and additional biological degradation.

Abichou, Tarek, E-mail: abichou@eng.fsu.edu [Department of Civil and Environmental Engineering, Florida State University, 2525 Pottsdamer Street, Tallahassee, FL 32311 (United States); Barlaz, Morton A. [Department of Civil, Construction, and Environmental Engineering, North Carolina State University, Raleigh, NC 27695 (United States); Green, Roger; Hater, Gary [Waste Management Inc., Cincinnati, OH 45211 (United States)

2013-10-15T23:59:59.000Z

390

Abstract--In this paper, the authors present the modelling of the impedance variation of an inverter DC bus. Modelling is  

E-Print Network [OSTI]

an analysis of the inverter DC bus in order to develop a new diagnostic method by the elec- tromagnetic field of an inverter DC bus. Modelling is done by application of the PEEC method (Partial Element Equivalent Circuit measurement [1]. Actually, the power of the electrical drives flows through the bus-bar, for this rea- son

Boyer, Edmond

391

BBSGI.MAN -BRANCH-BUS/SILICON GRAPHICS DATA ACQUISITION SYSTEM (BBSGI) For IRIX 5.x systems -AT&T UNIX System V Release 4  

E-Print Network [OSTI]

BBSGI.MAN - BRANCH-BUS/SILICON GRAPHICS DATA ACQUISITION SYSTEM (BBSGI) For IRIX 5.x systems - AT&T UNIX System V Release 4 r.imossi/oldf/bnl 25-Oct-1993 BRANCH-BUS/SILICON GRAPHICS DATA ACQUISITION The BRANCH-BUS/SILICON GRAPHICS DATA ACQUISITION SYSTEM (BBSGI) is a product of the Online Data Facility

392

Optimal Bus Stop Spacing for Minimizing Transit Operation Cost and Robert L. Bertini2  

E-Print Network [OSTI]

. Two cost functions are considered in the model including passenger access cost and in-vehicle1 Optimal Bus Stop Spacing for Minimizing Transit Operation Cost Huan Li1 and Robert L. Bertini2 model is generated with the aim at minimizing the operation cost without impact on transit accessibility

Bertini, Robert L.

393

Technology in Motion Vehicle (TMV) To promote truck and bus safety programs and  

E-Print Network [OSTI]

Technology in Motion Vehicle (TMV) Goal To promote truck and bus safety programs and technologies messages at multiple venues Demonstrate proven and emerging safety technologies to state and motor carrier stakeholders Promote deployment of safety technologies by fleets and state MCSAP agencies Evaluate program

394

Where's My Bus Stop? Supporting Independence of Blind Transit Riders with StopInfo  

E-Print Network [OSTI]

in the Seattle area with information entered by the community, primarily as they waited at these stops and Society]: Social Is sues--Assistive technologies for persons with disabilities General Terms Design]. They often search for physical landmarks such as the bus shelter, benches, or transit sign as a cue

Manchak, John

395

High voltage bus and auxiliary heater control system for an electric or hybrid vehicle  

DOE Patents [OSTI]

A control system for an electric or hybrid electric vehicle includes a vehicle system controller and a control circuit having an electric immersion heater. The heater is electrically connected to the vehicle's high voltage bus and is thermally coupled to a coolant loop containing a heater core for the vehicle's climate control system. The system controller responds to cabin heat requests from the climate control system by generating a pulse width modulated signal that is used by the control circuit to operate the heater at a duty cycle appropriate for the amount of cabin heating requested. The control system also uses the heater to dissipate excess energy produced by an auxiliary power unit and to provide electric braking when regenerative braking is not desirable and manual braking is not necessary. The control system further utilizes the heater to provide a safe discharge of a bank of energy storage capacitors following disconnection of the battery or one of the high voltage connectors used to transmit high voltage operating power to the various vehicle systems. The control circuit includes a high voltage clamping circuit that monitors the voltage on the bus and operates the heater to clamp down the bus voltage when it exceeds a pre-selected maximum voltage. The control system can also be used to phase in operation of the heater when the bus voltage exceeds a lower threshold voltage and can be used to phase out the auxiliary power unit charging and regenerative braking when the battery becomes fully charged.

Murty, Balarama Vempaty (West Bloomfield, MI)

2000-01-01T23:59:59.000Z

396

Mobile Journey Planning for Bus Passengers Desmond Rainsford and William A Mackaness  

E-Print Network [OSTI]

1 Mobile Journey Planning for Bus Passengers Desmond Rainsford and William A Mackaness Geography. Developments in mobile technology offer new ways of supporting mobile decision making. One application domain in the area of Location Based Services (LBS) is the delivery of journey plans to a mobile device. Few journey

397

ROMS-BioBUS in the Benguela forced by IPSL ouputs.  

E-Print Network [OSTI]

1 ROMS-BioBUS in the Benguela forced by IPSL ouputs. Tests on a statistical downscaling of the wind ­ present downscaled wind · Comparison IPSL ­ present versus Control · Conclusion and achievement #12 : Mortality of phytoplankton 4 : Grazing by zooplankton 5 : Production of faecal pellets 6: Mortality

398

IAC-09.C3.2.8 A REDUNDANT POWER BUS FOR  

E-Print Network [OSTI]

. The idea behind the proposed Power Bus is to have power conversion (from solar panels) and power storage") which contain, each: a solar panel; energy storage batteries with the corresponding power converters in a distributed way. For instance: i) accumulating the power from all solar panels towards the load(s); ii

399

Re-Dispatching Generation to Increase Power System Security Margin and Support Low Voltage Bus  

E-Print Network [OSTI]

Re-Dispatching Generation to Increase Power System Security Margin and Support Low Voltage Bus by re-dispatching generator outputs, using a normal vector found at a voltage collapse boundary or a low voltage boundary (LVB). This method uses the normal vector as an indicator to change the generation

400

AlAA 92-0980 Design of Multipurpose Spacecraft BUS  

E-Print Network [OSTI]

. The spacecraft bus uses three- axis stabilization consisting of three reaction wheel system. The electric power system consists of single-axis tracking silicon solar array and Ni2 H2 batteries. The propulsion differences in orbit, yaw axis control, attitude pointing, and thermal control requirements. The AVHRR payload

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

APPLIED STOCHASTIC MODELS IN BUSINESS AND INDUSTRY Appl. Stochastic Models Bus. Ind., 2006; 22:297311  

E-Print Network [OSTI]

APPLIED STOCHASTIC MODELS IN BUSINESS AND INDUSTRY Appl. Stochastic Models Bus. Ind., 2006; 22 Non-parametric modelling of time-varying customer service times at a bank call centre Haipeng Shen1 are interested in modelling the time-varying pattern of average customer service times at a bank call centre

Shen, Haipeng

402

Analysis of a Transit Bus as Probe Vehicle for Arterial Performance Measurement  

E-Print Network [OSTI]

of an arterial. First, we extract data from the bus dispatch system (BDS) of the Tri- County Metropolitan Transit District (TriMet), the transit provider for Portland, Oregon. Then, the performance characteristics engineers, planners, researchers, and transportation agencies have expended much effort trying to understand

Bertini, Robert L.

403

Connecticut Transit (CTTRANSIT) Fuel Cell Transit Bus: Second Evaluation Report and Appendices  

SciTech Connect (OSTI)

This report describes operations at Connecticut Transit (CTTRANSIT) in Hartford for one prototype fuel cell bus and three new diesel buses operating from the same location. The evaluation period in this report (January 2008 through February 2009) has been chosen to coincide with a UTC Power propulsion system changeout that occurred on January 15, 2008.

Chandler, K.; Eudy, L.

2009-05-01T23:59:59.000Z

404

SunLine Transit Agency Fuel Cell Transit Bus: Fourth Evaluation Report (Report and Appendices)  

SciTech Connect (OSTI)

This report describes operations at SunLine Transit Agency for a prototype fuel cell bus and five new compressed natural gas (CNG) buses. This is the fourth evaluation report for this site, and it describes results and experiences from April 2008 through October 2008. These results are an addition to those provided in the previous three evaluation reports.

Chandler, K.; Eudy, L.

2009-01-01T23:59:59.000Z

405

Interframe Bus Encoding Technique and Architecture for MPEG-4 AVC/H.264 Video Compression   

E-Print Network [OSTI]

In this paper, we propose an implementation of a data encoder to reduce the switched capacitance on a system bus. Our technique focuses on transferring raw video data for multiple reference frames between off-and on-chip memories in an MPEG-4 AVC...

Bahari, Asral; Arslan, Tughrul; Erdogan, Ahmet T.

406

TPE-CMS: A Comfort Measuring System for Public Bus Service in Taipei City  

E-Print Network [OSTI]

TPE-CMS: A Comfort Measuring System for Public Bus Service in Taipei City Cheng-Yu Lin and Ling Measuring System (CMS) for public transportation systems in Taipei city, called TPE-CMS. TPE-CMS exploits the GPS and G-sensor of modern smart phones to measure the comfort level of vehicle rides. Then, it mashes

Chen, Ling-Jyh

407

SunLine Transit Agency Fuel Cell Transit Bus: Fifth Evaluation Report (Report and Appendices)  

SciTech Connect (OSTI)

This report describes operations at SunLine Transit Agency for a prototype fuel cell bus and five compressed natural gas (CNG) buses. This is the fifth evaluation report for this site, and it describes results and experiences from October 2008 through June 2009. These results are an addition to those provided in the previous four evaluation reports.

Eudy, L.; Chandler, K.

2009-08-01T23:59:59.000Z

408

Definition and Evaluation of Bus and Truck Automation Operations Concepts: Final Report  

E-Print Network [OSTI]

fuel efficiency Higher system capacity Rural Truck-AHS Long-haulhaul other companies’ trucks or just trailers; scheduled AHS Hauling services Better fuelhaul on some freight corridors (expedited Bus and Truck AHS – Final Report to California PATH Mainline Operations: Fuel

Taso, H. S. Jacob; Botha, Jan L.

2003-01-01T23:59:59.000Z

409

The Overall Energy Balance of the Hydrogen Bus in Berkeley, CA  

E-Print Network [OSTI]

splitting plants 4 millions Uranium 7 large oil&gas SMR/gasification refineries 16 millions Oil, hydrogen compressor, hydrogen tanks, and a bus propelled by electrical motors driven by a 60 kW hydrogen/Methane Direct conversion of fossil fuels to hydrogen causes more CO2 and other GHG gas emissions than burning

Patzek, Tadeusz W.

410

SunLine Transit Agency Fuel Cell Transit Bus: Fifth Evaluation Report-- Appendices  

Broader source: Energy.gov [DOE]

This report describes operations at SunLine Transit Agency for a prototype fuel cell bus and five compressed natural gas (CNG) buses. This is the fifth evaluation report for this site, and it describes results and experiences from October 2008 through June 2009. These results are an addition to those provided in the previous four evaluation reports.

411

Real-time Bus Information on Mobile Devices Stuart D. Maclean, Daniel J. Dailey  

E-Print Network [OSTI]

on a variety of personal electronic devices. Within the wireless communications industry, the WAP Forum[2] has1 Real-time Bus Information on Mobile Devices Stuart D. Maclean, Daniel J. Dailey Abstract-- We restrictions of such devices, e.g., screen size and paucity of keyboard options, influences the user in

412

Impact evaluation of the energy retrofits installed in the Margolis high-rise apartment building, Chelsea housing authority  

SciTech Connect (OSTI)

As part of a joint demonstration effort involving HUD, DOE, a local public housing authority and Boston Edison, an evaluation of energy and demand saving retrofits was conducted for a tall, residential, low-income building located in Boston. The thirteen story building underwent window, lighting, and heating system control renovations in December, 1992. The success of these retrofits was determined using monthly and hourly whole-building consumption data along with a calibrated DOE-2.1D energy simulation model. According to the model developed, post-retrofit conditions showed reductions in annual energy consumption of 325 MWh and in peak demand of 100 kW. These savings resulted in an annual energy cost savings of $28,000. Over 90% of energy and cost savings were attributed to the window retrofit. Interaction of the reduction in lighting capacity with the building`s electric resistance heating system reduced the potential for energy and demand savings associated with the lighting retrofit. Results from the hourly simulation model also indicate that night setbacks controlled by the energy management system were not implemented. An additional 32 MWh in energy savings could be obtained by bringing this system on-line, however peak demand would be increased by 40 kW as the morning demand for space heat is increased, with a net loss in cost savings of $2,500.

Abraham, M.M.; McLain, H.A.; MacDonald, J.M.

1995-03-01T23:59:59.000Z

413

Amr Shaat, David Schnerch, Amir Fam, and Sami Rizkalla Retrofit of Steel Structures Using Fiber Reinforced Polymers (FRP): State-of-the-Art  

E-Print Network [OSTI]

on retrofit of steel members including repair of naturally corroded beams, repair of artificially notched and the durability of retrofitted systems, particularly the issue of galvanic corrosion. Available field applications heavy lifting equipment and can add considerably more dead load to the structure, which reduces

414

NCSU Box 7401 Raleigh, NC 27695 (919) 515-3480 Toll Free 1-800-33-NC SUN Passive Solar Retrofit  

E-Print Network [OSTI]

SOLAR CENTER INFORMATION Passive solar retrofit is the adding of solar features to an existing house you begin a passive solar retrofit, you should make sure that your house is energy) for your house. You may also want to review passive solar principles described in the Solar Center

415

Cost-Effectiveness of Home Energy Retrofits in Pre-Code Vintage Homes in the United States  

SciTech Connect (OSTI)

This analytical study examines the opportunities for cost-effective energy efficiency and renewable energy retrofits in residential archetypes constructed prior to 1980 (Pre-Code) in fourteen U.S. cities. These fourteen cities are representative of each of the International Energy Conservation Code (IECC) climate zones in the contiguous U.S. The analysis is conducted using an in-house version of EnergyGauge USA v.2.8.05 named CostOpt that has been programmed to perform iterative, incremental economic optimization on a large list of residential energy efficiency and renewable energy retrofit measures. The principle objectives of the study are as follows: to determine the opportunities for cost effective source energy reductions in this large cohort of existing residential building stock as a function of local climate and energy costs; and to examine how retrofit financing alternatives impact the source energy reductions that are cost effectively achievable.

Fairey, P.; Parker, D.

2012-11-01T23:59:59.000Z

416

Housing Archetype Analysis for Home Energy-Efficient Retrofit in the Great Lakes Region  

SciTech Connect (OSTI)

This project report details activities and results of the 'Market Characterization' project undertaken by the Cost Effective Energy Retrofit (CEER) team targeted toward the DOE goal of achieving 30%-50% reduction in existing building energy use. CEER consists of members from the Dow Chemical Company, Michigan State University, Ferris State University and Habitat for Humanity Kent County. The purpose of this market characterization project was to identify housing archetypes which are dominant within Great Lakes region and therefore offer significant potential for energy-efficient retrofit research and implementation due to the substantial number of homes possessing similar characteristics. Understanding the characteristics of housing groups referred to as 'archetypes' by vintage, style, and construction characteristics can allow research teams to focus their retrofit research and develop prescriptive solutions for those structure types which are prevalent and offer high potential uptake within a region or market. Key research activities included; literature review, statistical analysis of national and regional data of the American Housing Survey (AHS) collected by the U.S. Census Bureau, analysis of Michigan specific data, development of a housing taxonomy of architectural styles, case studies of two local markets (i.e., Ann Arbor and Grand Rapids in Michigan) and development of a suggested framework (or process) for characterizing local markets. In order to gain a high level perspective, national and regional data from the U.S. Census Bureau was analyzed using cross tabulations, multiple regression models, and logistic regression to characterize the housing stock and determine dominant house types using 21 variables.

Kim, S. K.; Mrozowski, T.; Harrell-Seyburn, A.; Ehrlich, N.; Hembroff, L.; Bieburn, B.; Mazor, M.; McIntyre, A.; Mutton, C.; Parsons, G.; Syal, M. G.; Wilkinson, R.

2014-09-01T23:59:59.000Z

417

Development of a Web-based Emissions Reduction Calculator for Street Light and Traffic Light Retrofits  

E-Print Network [OSTI]

Episode Peak day for 1999 4 . In the design mode the energy and emissions savings are calculated based on the specific information the user provides about the lamp type, lamp code, wattage, and number of lamps for both pre-retrofit and post... for the whole year is 12 hours per day. Traffic Light Analysis: Design Mode Table 2 shows an example of the input information and calculation for traffic light design mode. For each project the user enters the lamp type, lamp code, wattage per lamp...

Liu, Z.; Gilman, D.; Haberl, J. S.; Culp, C.

2005-01-01T23:59:59.000Z

418

Development of an advanced high efficiency coal combustor for boiler retrofit  

SciTech Connect (OSTI)

The objective of the program was to develop an advanced coal combustion system for firing beneficiated coal fuels (BCFs) capable of being retrofitted to industrial boilers originally designed for firing natural gas. The High Efficiency Advanced Coal Combustor system is capable of firing microfine coal-water fuel (MCWF), MCWF with alkali sorbent (for SO{sub 2} reduction), and dry microfine coal. Design priorities for the system were that it be simple to operate and offer significant reductions in NO{sub x}, SO{sub x}, and particulate emissions as compared with current coal-fired combustor technology. (VC)

LaFlesh, R.C.; Rini, M.J.; McGowan, J.G.; Beer, J.M.; Toqan, M.A.

1990-04-01T23:59:59.000Z

419

Development of an advanced high efficiency coal combustor for boiler retrofit. Summary report  

SciTech Connect (OSTI)

The objective of the program was to develop an advanced coal combustion system for firing beneficiated coal fuels (BCFs) capable of being retrofitted to industrial boilers originally designed for firing natural gas. The High Efficiency Advanced Coal Combustor system is capable of firing microfine coal-water fuel (MCWF), MCWF with alkali sorbent (for SO{sub 2} reduction), and dry microfine coal. Design priorities for the system were that it be simple to operate and offer significant reductions in NO{sub x}, SO{sub x}, and particulate emissions as compared with current coal-fired combustor technology. (VC)

LaFlesh, R.C.; Rini, M.J.; McGowan, J.G.; Beer, J.M.; Toqan, M.A.

1990-04-01T23:59:59.000Z

420

A systematic approach to energy efficiency retrofit solutions for exsisting office buildings  

E-Print Network [OSTI]

Institute of Energy Efficient and Sustainable Design and Building Prof. Dr.-Ing. Werner Lang Yunming Shao Prof. Dr.-Ing. Werner Lang Technical University of Munich, Germany 11/11/2014 A systematic approach to energy efficiency retrofit solutions... for existing office buildings ESL-IC-14-09-33 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Institute of Energy Efficient and Sustainable Design and Building Prof. Dr.-Ing. Werner Lang...

Shao,Y.

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Energy retrofit and occupant behaviour in protected housing: A case study of the Brunswick Centre in London  

E-Print Network [OSTI]

Accepted Manuscript Title: Energy retrofit and occupant behaviour in protected housing: A case study of the Brunswick Centre in London Author: Hui Ben Koen Steemers PII: S0378-7788(14)00411-3 DOI: http://dx.doi.org/doi:10.1016/j.enbuild.2014... .05.019 Reference: ENB 5055 To appear in: ENB Received date: 13-9-2013 Revised date: 9-5-2014 Accepted date: 14-5-2014 Please cite this article as: H. Ben, K. Steemers, Energy retrofit and occupant behaviour in protected housing: A case study of the Brunswick Centre...

Hui, Ben; Steemers, Koen

2014-05-26T23:59:59.000Z

422

Bounding Bus Delay and Noise Effects of On-Chip Inductance Michael Linderman, David Harris, David Diaz  

E-Print Network [OSTI]

Bounding Bus Delay and Noise Effects of On-Chip Inductance Michael Linderman, David Harris, David Diaz Harvey Mudd College 301 E 12th St. Claremont, CA 91711 mlinderman@stanford.edu, david_harris

Harris, David Money

423

Leveraging bus rapid transit lite for transit corridor development : Springfield Avenue and Bloomfield Avenue in Newark NJ  

E-Print Network [OSTI]

The construction of bus rapid transit lite (BRT lite) systems on Springfield Avenue and Bloomfield Avenue in Newark is assumed to provide lower travel times and improved reliability of service to local and regional economic ...

Kintala, Kumar

2008-01-01T23:59:59.000Z

424

An Efficient Model for Planning Bus Routes in Communities with Populations Between 20,000 and 250,000  

E-Print Network [OSTI]

The paper discusses a flexible, inexpensive, interactive computer model specifically designed to act as an aid for planning routes for conventional bus systems in communities with populations between 20,000 and 250,000. ...

Hauser, John R.

425

The potential for bus rapid transit to promote transit oriented development : an analysis of BRTOD in Ottawa, Brisbane, and Pittsburgh  

E-Print Network [OSTI]

This thesis explores the conditions under which bus rapid transit (BRT) can promote transit oriented development (TOD). At a time when cities throughout the U.S. are searching for methods to reduce road congestion and limit ...

Judy, Meredith H. (Meredith Hampton)

2007-01-01T23:59:59.000Z

426

Multilevel-Dc-Bus Inverter For Providing Sinusoidal And Pwm Electrical Machine Voltages  

DOE Patents [OSTI]

A circuit for controlling an ac machine comprises a full bridge network of commutation switches which are connected to supply current for a corresponding voltage phase to the stator windings, a plurality of diodes, each in parallel connection to a respective one of the commutation switches, a plurality of dc source connections providing a multi-level dc bus for the full bridge network of commutation switches to produce sinusoidal voltages or PWM signals, and a controller connected for control of said dc source connections and said full bridge network of commutation switches to output substantially sinusoidal voltages to the stator windings. With the invention, the number of semiconductor switches is reduced to m+3 for a multi-level dc bus having m levels. A method of machine control is also disclosed.

Su, Gui-Jia [Knoxville, TN

2005-11-29T23:59:59.000Z

427

{open_quotes}Secure Bus{close_quotes} disturbance-free power at the utility substation level  

SciTech Connect (OSTI)

Over the last 18 months Public Service Company of New Mexico (PNM), El Camino Real Engineering, Inc. (CRE), Los Alamos National Laboratory (LANL) and Sandia National Laboratories (SNL) have worked on the development of disturbance-free power at the medium voltage substation level. The work resulted in the Secure Bus concept, a system in which a medium voltage bus in a substation is immune to power outages and voltage sags on the utility source. The Secure Bus voltage is also immune to voltage sags resulting from faults on any distribution feeder connected to the bus. The Secure Bus concept originated from work conducted to improve power quality for large high-tech manufacturing facilities, in particular for large semiconductor manufacturing plants. For the demands on quality power of a modern facility conventional equipment is not adequate for protecting the end user. For example, the operation of conventional vacuum breakers during short circuit conditions on a feeder circuit, requiring 3 to 5 cycles for breaker opening, does not allow for fast enough current interruption to avoid a voltage dip on the main bus. A sever voltage sag could result in a shut down of sensitive equipment being supplied by the other feeder circuits, which are connected to the main bus. The circumvent the problem, a fast breaker was introduced which interrupts the short circuit before the current causes a significant voltage disturbance. To make the bus immune also to power disturbances caused by power outages, energy storage is introduced to provide the necessary energy back-up in case the primary source is not available.

Boenig, H.J. [Los Alamos National Lab., NM (United States); Jones, W.H. [El Camino Real Engineering, Inc., Corrales, NM (United States)

1996-12-01T23:59:59.000Z

428

National Fuel Cell Bus Program: Accelerated Testing Evaluation Report and Appendices, Alameda-Contra Costa Transit District (AC Transit)  

SciTech Connect (OSTI)

This is an evaluation of hydrogen fuel cell transit buses operating at AC Transit in revenue service since March 20, 2006 compared to similar diesel buses operating from the same depot. This evaluation report includes results from November 2007 through October 2008. Evaluation results include implementation experience, fueling station operation, fuel cell bus operations at Golden Gate Transit, and evaluation results at AC Transit (bus usage, availability, fuel economy, maintenance costs, and roadcalls).

Chandler, K.; Eudy, L.

2009-01-01T23:59:59.000Z

429

St. Louis Metro Biodiesel (B20) Transit Bus Evaluation: 12-Month Final Report  

SciTech Connect (OSTI)

The St. Louis Metro Bodiesel Transit Bus Evaluation project is being conducted under a Cooperative Research and Development Agreement between NREL and the National Biodiesel Board to evaluate the extended in-use performance of buses operating on B20 fuel. The objective of this research project is to compare B20 and ultra-low sulfur diesel buses in terms of fuel economy, veicles maintenance, engine performance, component wear, and lube oil performance.

Barnitt, R.; McCormick, R. L.; Lammert, M.

2008-07-01T23:59:59.000Z

430

Retrofit of existing 400 horsepower air compressor motor with steam turbine  

SciTech Connect (OSTI)

This paper is on the completion of a retrofit project to replace an existing 400 Horsepower air compressor motor with a steam turbine. The discussion includes visuals to show the process involved in carrying out this project. There will be in three parts. The first part of the presentation will cover the planning and construction. Planning included defining a scope, collecting data to support this scope, determining engineering feasibility, and calculating an economic payback. Construction will include the preparations for the retrofit including details of upgrades to existing systems and components, and installation of new systems and components. This will be followed by details on the actual removal of the motor, installation of the turbine, and the revision of the controls. Startup of the air compressor on steam is then discussed including necessary preparation of steam systems. Next to be presented will be some of the problems and their solutions experienced during this project. Specifically discussed will be regulatory concerns, noise of operation, insurance, and fluctuations in plant process steam demand. The conclusion of the presentation will focus on present operating status, savings demonstrated, and maintenance required.

Sanders, S.F.

1997-06-01T23:59:59.000Z

431

Predicted Versus Actual Savings for a Low-Rise Multifamily Retrofit in Boulder, Colorado  

SciTech Connect (OSTI)

To determine the most cost-effective methods of improving buildings, accurate analysis and prediction of the energy use of existing buildings is essential. However, multiple studies confirm that analysis methods tend to over-predict energy use in poorly insulated, leaky homes and thus, the savings associated with improving those homes. In NREL's report titled 'Assessing and Improving the Accuracy of Energy Analysis of Residential Buildings,' researchers propose a method for improving the accuracy of residential energy analysis methods. A key step in this process involves the comparisons of predicted versus metered energy use and savings. In support of this research need, CARB evaluated the retrofit of a multifamily building in Boulder, CO. The updated property is a 37 unit, 2 story apartment complex built in 1950, which underwent renovations in early 2009 to bring it into compliance with Boulder, CO's SmartRegs ordinance. Goals of the study were to: 1) evaluate predicted versus actual savings due to the improvements, 2) identify areas where the modeling assumptions may need to be changed, and 3) determine common changes made by renters that would negatively impact energy savings. In this study, CARB seeks to improve the accuracy of modeling software while assessing retrofit measures to specifically determine which are most effective for large multifamily complexes in the cold climate region. Other issues that were investigated include the effects of improving building efficiency on tenant comfort, the impact on tenant turnover rates, and the potential market barriers for this type of community scale project.

Arena, L.; Williamson, J.

2013-11-01T23:59:59.000Z

432

Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)  

SciTech Connect (OSTI)

The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit energy efficiency measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings nationwide. U.S. K-12 school districts spend more than $8 billion each year on energy - more than they spend on computers and textbooks combined. Most occupy older buildings that often have poor operational performance - more than 30% of schools were built before 1960. The average age of a school is about 42 years - which is nearly the expected serviceable lifespan of the building. K-12 schools offer unique opportunities for deep, cost-effective energy efficiency improvements, and this guide provides convenient and practical guidance for exploiting these opportunities in the context of public, private, and parochial schools.

Not Available

2013-12-01T23:59:59.000Z

433

IMPROVEMENT TO PIPELINE COMPRESSOR ENGINE RELIABILITY THROUGH RETROFIT MICRO-PILOT IGNITION SYSTEM  

SciTech Connect (OSTI)

This report documents a 3-year research program conducted by the Engines & Energy Conversion Laboratory (EECL) at Colorado State University (CSU) to develop micropilot ignition systems for existing pipeline compressor engines. Research activities for the overall program were conducted with the understanding that the efforts are to result in a commercial product to capture and disseminate the efficiency and environmental benefits of this new technology. An extensive state-of-art review was conducted to leverage the existing body of knowledge of micropilot ignition with respect to retrofit applications. Additionally, commercially-available fuel injection products were identified and applied to the program where appropriate. This approach will minimize the overall time-to-market requirements, while meeting performance and cost criteria. The objective for Phase I was to demonstrate the feasibility of micropilot ignition for large bore, slow speed engines operating at low compression ratios under laboratory conditions at the EECL. The primary elements of Micropilot Phase I were to develop a single-cylinder test chamber to study the injection of pilot fuel into a combustion cylinder and to develop, install and test a multi-cylinder micropilot ignition system for a 4-cylinder, natural gas test engine. In all, there were twelve (12) tasks defined and executed to support these two (2) primarily elements in a stepwise fashion. Task-specific approaches and results are documented in this report. The four-cylinder prototype data was encouraging for the micro-pilot ignition technology when compared to spark ignition. The objective for Phase II was to further develop and optimize the micropilot ignition system at the EECL for large bore, slow speed engines operating at low compression ratios. The primary elements of Micropilot Phase II were to evaluate the results for the 4-cylinder system prototype developed for Phase I, then optimize this system and prepare the technology for the field demonstration phase in Year 3. In all, there were twelve (12) tasks defined and executed to support objectives in a stepwise fashion. The optimized four-cylinder system data demonstrated significant progress compared to Phase I results, as well as traditional spark ignition systems. These laboratory results were enhanced, then verified via a field demonstration project during Phase III of the Micropilot Ignition program. An Implementation Team of qualified engine retrofit service providers was assembled to install the retrofit micropilot ignition system on an engine operated by El Paso Pipeline Group at a compressor station near Window Rock, Arizona. Testing of this demonstration unit showed that the same benefits identified by laboratory testing at CSU, i.e., reduced fuel consumption and exhaust emissions (NOx, THC, CO, and CH2O). Commercialization of the retrofit micropilot ignition technology is awaiting a ''market pull'', which is expected to materialize as the results of the field demonstration become known and accepted. The Implementation Team, comprised of Woodward Governor Company, Enginuity LLC, Hoerbiger Corporation of America, and DigiCon Inc., has direct experience with the technology development and implementation, and stands ready to promote and commercialize the retrofit micropilot ignition system.

Scott Chase; Daniel Olsen; Ted Bestor

2005-05-01T23:59:59.000Z

434

The Value of the EWIT Computer Program in Identifying Economically Viable Retrofit Options for Existing Commercial Buildings  

E-Print Network [OSTI]

EWIT's potential as a tool for evaluating retrofit options for existing commercial buildings. To achieve this goal two case buildings in the Denver area were analyzed by means of the EWIT program. The first building is a one story structure of 10...

Andrews, W. M.

1984-01-01T23:59:59.000Z

435

Feasibility of Retrofitting Centralized HVAC Systems for Room-Level Zoning Tamim Sookoor, Brian Holben, Kamin Whitehouse  

E-Print Network [OSTI]

Feasibility of Retrofitting Centralized HVAC Systems for Room-Level Zoning Tamim Sookoor, Brian {sookoor,bnh4k,whitehouse}@cs.virginia.edu Abstract--Heating, ventilation, and cooling (HVAC) accounts's largest energy consumers. Many attempts have been made to optimize the control of HVAC systems

Whitehouse, Kamin

436

CASE STUDY OF DUCT RETROFIT OF A 1985 HOME AND GUIDELINES FOR ATTIC AND CRAWL SPACE DUCT SEALING  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) is fully committed to research for developing the information and capabilities necessary to provide cost-effective residential retrofits yielding 50% energy savings within the next several years. Heating, ventilation, and air conditioning (HVAC) is the biggest energy end use in the residential sector, and a significant amount of energy can be wasted through leaky ductwork in unconditioned spaces such as attics and crawl spaces. A detailed duct sealing case study is presented for one house along with nine brief descriptions of other duct retrofits completed in the mixed-humid climate. Costs and estimated energy savings are reported for most of the ten houses. Costs for the retrofits ranged from $0.92/ft2 to $1.80/ft2 of living space and estimated yearly energy cost savings due to the duct retrofits range from 1.8% to 18.5%. Lessons learned and duct sealing guidelines based on these ten houses, as well as close work with the HVAC industry in the mixed-humid climate of East Tennessee, northern Georgia, and south-central Kentucky are presented. It is hoped that the lessons learned and guidelines will influence local HVAC contractors, energy auditors, and homeowners when diagnosing or repairing HVAC duct leakage and will be useful for steering DOE s future research in this area.

Boudreaux, Philip R [ORNL; Christian, Jeffrey E [ORNL; Jackson, Roderick K [ORNL

2012-01-01T23:59:59.000Z

437

New test procedure evaluates quality and accuracy of energy analysis tools for the residential building retrofit market.  

E-Print Network [OSTI]

New test procedure evaluates quality and accuracy of energy analysis tools for the residential that calculate optimal packages of efficiency measures. To improve the accuracy of energy analysis building retrofit market. Reducing the energy use of existing homes in the United States offers significant

438

Evaluation of energy savings related to building envelope retrofit techniques and ventilation strategies for low energy cooling in  

E-Print Network [OSTI]

Evaluation of energy savings related to building envelope retrofit techniques and ventilation strategies for low energy cooling in offices and commercial sector Laurent Grignon-Massé, Dominique Marchio-use Efficiency Research Group Abstract The energy savings achievable in the end-use space cooling depend

Paris-Sud XI, Université de

439

A Meta-Analysis of Single-Family Deep Energy Retrofit Performance in the U.S.  

SciTech Connect (OSTI)

The current state of Deep Energy Retrofit (DER) performance in the U.S. has been assessed in 116 homes in the United States (US), using actual and simulated data gathered from the available domestic literature. Substantial airtightness reductions averaging 63% (n=48) were reported (two- to three-times more than in conventional retrofits), with average post-retrofit airtightness of 4.7 Air Changes per House at 50 Pascal (ACH50) (n=94). Yet, mechanical ventilation was not installed consistently. In order to avoid indoor air quality (IAQ) issues, all future DERs should comply with ASHRAE 62.2-2013 requirements or equivalent. Projects generally achieved good energy results, with average annual net-site and net-source energy savings of 47%±20% and 45%±24% (n=57 and n=35), respectively, and carbon emission reductions of 47%±22% (n=23). Net-energy reductions did not vary reliably with house age, airtightness, or reported project costs, but pre-retrofit energy usage was correlated with total reductions (MMBtu). Annual energy costs were reduced $1,283±$804 (n=31), from a pre-retrofit average of $2,738±$1,065 to $1,588±$561 post-retrofit (n=25 and n=39). The average reported incremental project cost was $40,420±$30,358 (n=59). When financed on a 30-year term, the median change in net-homeownership cost was only $1.00 per month, ranging from $149 in savings to an increase of $212 (mean=$15.67±$87.74; n=28), and almost half of the projects resulted in reductions in net-cost. The economic value of a DER may be much greater than is suggested by these net-costs, because DERs entail substantial non-energy benefits (NEBs), and retrofit measures may add value to a home at resale similarly to general remodeling, PV panel installation, and green/energy efficient home labels. These results provide estimates of the potential of DERs to address energy use in existing homes across climate zones that can be used in future estimates of the technical potential to reduce household energy use and greenhouse gas emissions through DERs.

Less, Brennan; Walker, Iain

2014-03-01T23:59:59.000Z

440

Assessment of the Applicability of Cooperative Vehicle-Highway Automation Systems to Bus Transit and Intermodal Freight: Case Study Feasibility Analyses in the Metropolitan Chicago Region  

E-Print Network [OSTI]

it is a form of vehicle automation that could be implementedare developed. For full automation, vehicle-roadway wirelessof Cooperative Vehicle-Highway Automation Systems to Bus

2004-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Proposal to negotiate an amendment to a blanket purchase contract for the supply and installation of water-cooled bus bars and cables for the LHC  

E-Print Network [OSTI]

Proposal to negotiate an amendment to a blanket purchase contract for the supply and installation of water-cooled bus bars and cables for the LHC

2014-01-01T23:59:59.000Z

442

An Assessment of Envelope Measures in Mild Climate Deep Energy Retrofits  

SciTech Connect (OSTI)

Energy end-uses and interior comfort conditions have been monitored in 11 Deep Energy Retrofits (DERs) in a mild marine climate. Two broad categories of DER envelope were identified: first, bringing homes up to current code levels of insulation and airtightness, and second, enhanced retrofits that go beyond these code requirements. The efficacy of envelope measures in DERs was difficult to determine, due to the intermingled effects of enclosure improvements, HVAC system upgrades and changes in interior comfort conditions. While energy reductions in these project homes could not be assigned to specific improvements, the combined effects of changes in enclosure, HVAC system and comfort led to average heating energy reductions of 76percent (12,937 kWh) in the five DERs with pre-retrofit data, or 80percent (5.9 kWh/ft2) when normalized by floor area. Overall, net-site energy reductions averaged 58percent (15,966 kWh; n=5), and DERs with code-style envelopes achieved average net-site energy reductions of 65percent (18,923 kWh; n=4). In some homes, the heating energy reductions were actually larger than the whole house reductions that were achieved, which suggests that substantial additional energy uses were added to the home during the retrofit that offset some heating savings. Heating system operation and energy use was shown to vary inconsistently with outdoor conditions, suggesting that most DERs were not thermostatically controlled and that occupants were engaged in managing the indoor environmental conditions. Indoor temperatures maintained in these DERs were highly variable, and no project home consistently provided conditions within the ASHRAE Standard 55-2010 heating season comfort zone. Thermal comfort and heating system operation had a large impact on performance and were found to depend upon the occupant activities, so DERs should be designed with the occupants needs and patterns of consumption in mind. Beyond-code building envelopes were not found to be strictly necessary for the achievement of deep energy savings in existing uninsulated homes in mild marine climates, provided that other energy end-uses were comprehensively reduced. We recommend that mild climate DERs pursue envelopes in compliance with the 2012 International Energy Conservation Code (IECC) and pair these with high efficiency, off-the-shelf HVAC equipment. Enhanced building envelopes should be considered in cases where very low heating energy use (<1,000 kWh/year or <0.5 kWh/ft2-year) and enhanced thermal comfort (ASHRAE 55-2010) are required, as well as in those situations where substantial energy uses are added to the home, such as decorative lighting, cooling or smart home A/V and communication equipment.

Walker, Iain; Less, Brennan

2014-06-01T23:59:59.000Z

443

Hygric Redistribution in Insulated Assemblies: Retrofitting Residential Envelopes Without Creating Moisture Issues  

SciTech Connect (OSTI)

The Building America program has recognized that most of the current housing stock is in need of energy related retrofits. One of the best ways of reducing the space conditioning energy consumption is to improve the thermal performance of the enclosure by adding exterior board foam insulation. This report quantifies the amount of water that can become trapped in the drainage cavity of typical wall systems, and measures the effect of water trapped in the drainage cavity on the moisture content of the sheathing. This study also attempts to explain the discrepancy between hygrothermal simulations and field performance of low permeance, low R-value exterior insulation (e.g. 3/4-in. foil faced polyisocyanurate) in cold climates.

Smegal, J.; Lstiburek, J.

2013-01-01T23:59:59.000Z

444

Exploring Cost-Effective, High Performance Residential Retrofits for Affordable Housing in the Hot Humid Climate  

SciTech Connect (OSTI)

In 2009, a Department of Energy Building America team led by the Florida Solar Energy Center began working with partners to find cost-effective paths for improving the energy performance of existing homes in the hot humid climate. A test-in energy audit and energy use modeling of the partner's proposed renovation package was performed for 41 affordable and middle income foreclosed homes in Florida and Alabama. HERS1 Indices ranged from 92 to 184 with modeled energy savings ranging from 3% to 50% (average of 26%). Analyses and recommendations were discussed with partners to encourage more efficient retrofits, highlight health and safety issues, and gather feedback on incremental cost of high performance measures. Ten completed renovations have modeled energy savings ranging from 9% to 48% (average 31%.) This paper presents the project's process including our findings thus far and highlights of the first home to meet the target HERS Index of 70.

McIlvaine, Janet; Sutherland, Karen; Schleith, Kevin; Chandra, Subrato

2010-08-27T23:59:59.000Z

445

AMERICAN ELECTRIC POWER'S CONESVILLE POWER PLANT UNIT NO.5 CO2 CAPTURE RETROFIT STUDY  

SciTech Connect (OSTI)

ALSTOM Power Inc.'s Power Plant Laboratories (ALSTOM) has teamed with American Electric Power (AEP), ABB Lummus Global Inc. (ABB), the US Department of Energy National Energy Technology Laboratory (DOE NETL), and the Ohio Coal Development Office (OCDO) to conduct a comprehensive study evaluating the technical feasibility and economics of alternate CO{sub 2} capture and sequestration technologies applied to an existing US coal-fired electric generation power plant. The motivation for this study was to provide input to potential US electric utility actions concerning GHG emissions reduction. If the US decides to reduce CO{sub 2} emissions, action would need to be taken to address existing power plants. Although fuel switching from coal to natural gas may be one scenario, it will not necessarily be a sufficient measure and some form of CO{sub 2} capture for use or disposal may also be required. The output of this CO{sub 2} capture study will enhance the public's understanding of control options and influence decisions and actions by government, regulators, and power plant owners in considering the costs of reducing greenhouse gas CO{sub 2} emissions. The total work breakdown structure is encompassed within three major reports, namely: (1) Literature Survey, (2) AEP's Conesville Unit No.5 Retrofit Study, and (3) Bench-Scale Testing and CFD Evaluation. The report on the literature survey results was issued earlier by Bozzuto, et al. (2000). Reports entitled ''AEP's Conesville Unit No.5 Retrofit Study'' and ''Bench-Scale Testing and CFD Evaluation'' are provided as companion volumes, denoted Volumes I and II, respectively, of the final report. The work performed, results obtained, and conclusions and recommendations derived therefrom are summarized.

Carl R. Bozzuto; Nsakala ya Nsakala; Gregory N. Liljedahl; Mark Palkes; John L. Marion

2001-06-30T23:59:59.000Z

446

EnergyFit Nevada (formerly known as the Nevada Retrofit Initiative) final report and technical evaluation  

SciTech Connect (OSTI)

The EnergyFit Nevada (EFN) Better Buildings Neighborhood Program (BBNP, and referred to in this document as the EFN program) currently encourages Nevada residents to make whole-house energy-efficient improvements by providing rebates, financing, and access to a network of qualified home improvement contractors. The BBNP funding, consisting of 34 Energy Efficiency Conservation Block Grants (EECBG) and seven State Energy Program (SEP) grants, was awarded for a three-year period to the State of Nevada in 2010 and used for initial program design and implementation. By the end of first quarter in 2014, the program had achieved upgrades in 553 homes, with an average energy reduction of 32% per home. Other achievements included: ? Completed 893 residential energy audits and installed upgrades in 0.05% of all Nevada single-family homes1 ? Achieved an overall conversation rate of 38.1%2 ? 7,089,089 kWh of modeled energy savings3 ? Total annual homeowner energy savings of approximately $525,7523 ? Efficiency upgrades completed on 1,100,484 square feet of homes3 ? $139,992 granted in loans to homeowners for energy-efficiency upgrades ? 29,285 hours of labor and $3,864,272 worth of work conducted by Nevada auditors and contractors4 ? 40 contractors trained in Nevada ? 37 contractors with Building Performance Institute (BPI) certification in Nevada ? 19 contractors actively participating in the EFN program in Nevada 1 Calculated using 2012 U.S. Census data reporting 1,182,870 homes in Nevada. 2 Conversion rate through March 31, 2014, for all Nevada Retrofit Initiative (NRI)-funded projects, calculated using the EFN tracking database. 3 OptiMiser energy modeling, based on current utility rates. 4 This is the sum of $3,596,561 in retrofit invoice value and $247,711 in audit invoice value.

Carvill, Anna; Bushman, Kate; Ellsworth, Amy

2014-06-17T23:59:59.000Z

447

Measured Effects of Retrofits - A Refrigerant Oil Additive and a Condenser Spray Device - On the Cooling Performance of a Heat Pump  

E-Print Network [OSTI]

A 15-year old, 3-ton single package air-to-air heat pump was tested in laboratory environmental chambers simulating indoor and outdoor conditions. After documenting initial performance, the unit was retrofitted with a prototype condenser water...

Levins, W. P.; Sand, J. R.; Baxter, V. D.; Linkous, R. S.

1996-01-01T23:59:59.000Z

448

Compressed Natural Gas (CNG) Transit Bus Experience Survey: April 2009--April 2010  

SciTech Connect (OSTI)

This survey was commissioned by the U.S. Department of Energy (DOE) and the National Renewable Energy Laboratory (NREL) to collect and analyze experiential data and information from a cross-section of U.S. transit agencies with varying degrees of compressed natural gas (CNG) bus and station experience. This information will be used to assist DOE and NREL in determining areas of success and areas where further technical or other assistance might be required, and to assist them in focusing on areas judged by the CNG transit community as priority items.

Adams, R.; Horne, D. B.

2010-09-01T23:59:59.000Z

449

Set up DataBus as a system service? | OpenEI Community  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar PowerstoriesNrelPartnerTypePonsa, Mallorca:up DataBus as a system service? Home

450

South Africa-GTZ Bus Rapid Transit Johannesburg | Open Energy Information  

Open Energy Info (EERE)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of InspectorConcentrating Solar PowerstoriesNrelPartnerTypePonsa,Home Aimeebailey'sSolazymeGTZ Bus Rapid Transit

451

Oxy-fuel Combustion and Integrated Pollutant Removal as Retrofit Technologies for Removing CO2 from Coal Fired Power Plants  

SciTech Connect (OSTI)

One third of the US installed capacity is coal-fired, producing 49.7% of net electric generation in 20051. Any approach to curbing CO2 production must consider the installed capacity and provide a mechanism for preserving this resource while meeting CO2 reduction goals. One promising approach to both new generation and retrofit is oxy-fuel combustion. Using oxygen instead of air as the oxidizer in a boiler provides a concentrated CO2 combustion product for processing into a sequestration-ready fluid.... Post-combustion carbon capture and oxy-fuel combustion paired with a compression capture technology such as IPR are both candidates for retrofitting pc combustion plants to meet carbon emission limits. This paper will focus on oxy-fuel combustion as applied to existing coal power plants.

Ochs, T.L.; Oryshchyn, D.B.; Summers, C.A.; Gerdemann, S.J.

2001-01-01T23:59:59.000Z

452

Demonstration Assessment of Light-Emitting Diode (LED) Retrofit Lamps at the Lobby of the Bonneville Power Administration, Portland, OR  

SciTech Connect (OSTI)

This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in the lobby of the Bonneville Power Administration (BPA) headquarters building in Portland, Oregon. The project involved a simple retrofit of 32 track lights used to illuminate historical black-and-white photos and printed color posters from the 1930s and 1940s. BPA is a federal power marketing agency in the Northwestern United States, and selected this prominent location to demonstrate energy efficient light-emitting diode (LED) retrofit options that not only can reduce the electric bill for their customers but also provide attractive alternatives to conventional products, in this case accent lighting for BPA's historical artwork.

Miller, Naomi

2011-07-01T23:59:59.000Z

453

Statistical Characterization of School Bus Drive Cycles Collected via Onboard Logging Systems  

SciTech Connect (OSTI)

In an effort to characterize the dynamics typical of school bus operation, National Renewable Energy Laboratory (NREL) researchers set out to gather in-use duty cycle data from school bus fleets operating across the country. Employing a combination of Isaac Instruments GPS/CAN data loggers in conjunction with existing onboard telemetric systems resulted in the capture of operating information for more than 200 individual vehicles in three geographically unique domestic locations. In total, over 1,500 individual operational route shifts from Washington, New York, and Colorado were collected. Upon completing the collection of in-use field data using either NREL-installed data acquisition devices or existing onboard telemetry systems, large-scale duty-cycle statistical analyses were performed to examine underlying vehicle dynamics trends within the data and to explore vehicle operation variations between fleet locations. Based on the results of these analyses, high, low, and average vehicle dynamics requirements were determined, resulting in the selection of representative standard chassis dynamometer test cycles for each condition. In this paper, the methodology and accompanying results of the large-scale duty-cycle statistical analysis are presented, including graphical and tabular representations of a number of relationships between key duty-cycle metrics observed within the larger data set. In addition to presenting the results of this analysis, conclusions are drawn and presented regarding potential applications of advanced vehicle technology as it relates specifically to school buses.

Duran, A.; Walkowicz, K.

2013-10-01T23:59:59.000Z

454

A Study of Environmental Load Reduction Technique for University Facilities Part10 Retrofitting heat source based on diagnostic results  

E-Print Network [OSTI]

-conditioning system in university facilities. Authors analyze the effect of CO2 emission reduction by retrofit. Simulation tools used are FACES and LCEM. 1. CO2 CO2 (TSCP)1)2006 2012CO215 TSCP 2. 1200 CO2 35 1000ton-CO2 35 75 CO2 2) 1 30 24CO2 15 1 RC 5 1 16,510m2 10131m2 6379m2

Miyashita, Yasushi

455

How to use the SC18IM700 to control any I2C-bus device Rev. 01 --5 December 2005 Application note  

E-Print Network [OSTI]

Application note Document information Info Content Keywords I2C, I2C controller, Master I2C, UART Abstract allows the host to control devices that have serial host bus interfaces that are not native to the system must have an integrated I2C-bus controller on-board, or it must have an external, stand-alone I2C

Berns, Hans-Gerd

456

Roof and Attic Design Guidelines for new and retrofit Construction of Homes in Hot and Coild Climates  

SciTech Connect (OSTI)

Some guidelines for improving the energy efficiency of roofs and attics are presented and are based on the research of the DOE Building Technology. The results of combined analytical and experimental studies were used to benchmark computer tools, which in turn, were used to simulate homes in hot and cold climates. Adding floor and roof insulation, above deck ventilation, radiant barriers, cool color shingle, metal or tile roofs, sealing the attic floor, sealing the duct system and sealing the attic were simulated to compute the cost of energy savings. Results are prioritized to help building owners make an informed economic decision when contemplating roof and attic retrofits. Sealing the attic floor is a top retrofit option. The sealed attic approach and a new prototype roof assembly an insulated and ventilated roof are good options for retrofit work but have paybacks ranging from 15 to 25 years. A new sealed attic concept was simulated and computations show its simple payback is about 10 to 12 years in hot and cold climates; its first cost is significantly reduced from that of a spray foam approach. For new construction the best option is to keep the ducts out of the attic, make sure the attic floor is sealed and add at least code level of insulation to the ceiling.

Desjarlais, Andre Omer [ORNL] [ORNL; LaFrance, Marc [International Energy Agency] [International Energy Agency

2013-01-01T23:59:59.000Z

457

SELECTING THE BEST POINT OF CONNECTION FOR SHUNT ACTIVE FILTERS IN MULTI-BUS POWER DISTRIBUTION SYSTEMS  

E-Print Network [OSTI]

and reliability. The selection of the active filter point of connection in multi-bus power distribution systems to the power distribution system, the point of connection must be carefully selected so the generated harmonic components flow to the nonlinear loads and do not propagate through the distribution system. In this paper

Catholic University of Chile (Universidad Católica de Chile)

458

THE SELF-ADJUSTING CURRENT-FED PUSH-PULL PARALLEL RESONANT INVERTER AS A HIGH FREQUENCY AC BUS DRIVER  

E-Print Network [OSTI]

. The power inverter is based on a Current-Fed Push-Pull Parallel-Resonant Inverter (CFPPRI), which includes power eliminates some of the conversion units, it poses new design challenges [1]: (a) ElectromagneticTHE SELF-ADJUSTING CURRENT-FED PUSH-PULL PARALLEL RESONANT INVERTER AS A HIGH FREQUENCY AC BUS

459

A Study of the Filling of Wall Cavities With Retrofit Wall Insulation.  

SciTech Connect (OSTI)

The Pacific Northwest Power Marketing Agency, the Bonneville Power Administration (BPA), conducted a retrofit wall insulation study to determine the effects of various obstructions within a wall cavity, where voids are likely to occur, and preferred filling methods and material types. The insulation test structure was composed of four 8-foot /times/ 12-foot walls, and was built using standard construction practices. The inside walls were clear plastic glazing, instead of gypsum board, to enable viewing of the filling process. A total of eight tests were performed: four cellulose, two rockwool, and two fiberglass. One- and two-hole filling methods were observed. All insulations were found to perform in the same basic manner with all experiencing the same problem areas. Common installer problems were empty spaces at the tops of cavities and missed cavities, especially above headers. Wiring and lath and plaster consistently caused reduced insulation densities in cavities. The problems with wiring, lath and plaster, and other features in the wall cavities were avoided with the use of a filler tube. The filler tube also provided a more consistent fill along the length of the entire cavity. 2 figs., 3 tabs.

Flores, Joseph A.; Grill, Alan R.

1988-08-01T23:59:59.000Z

460

The retrofit of the lignite based 420 T/H boiler  

SciTech Connect (OSTI)

The investment program of RENEL is based on conclusions of development studies, that derived the cost effective production capacities evolution from demand evaluation for short and medium horizons in time. The current situation of fossil generating capacities for electricity and heat is characterized by lack of performance. This is primarily due to obsolescence, both from aging and from initial bad design. Another contribution is that of current fuel quality, worse than the initial design one. Finally, operation and maintenance, different from proper standards, have had a contribution to the degradation of performance also. The lack of performance was not a big problem in the period after the events of year 1989, installed power being much larger than demand, that experienced an important decrease, mainly because of lower industry consumption. However, some shortages appeared in district heating supply, in towns where demand is bigger than installed capacity (e.g. Bucharest). The lack of performance will become a problem when the Romanian network will be interconnected with UCPTE (European Grid), the frequency - load control being very demanding with respect to control quality. This is also important for the economical point of view, having an important impact on costs. The last aspect, but not the least, is the environmental impact of fossil fueled generating capacities. The mentioned development studies indicated that at the present, retrofitting of fossil-fired units is more cost effective than new investment.

Pavnotescu, O.; Totolo, C.

1997-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Conceptual design of a coal-fired MHD retrofit. Final technical report  

SciTech Connect (OSTI)

Coal-fired magnetohydrodynamics (MHD) technology is ready for its next level of development - an integrated demonstration at a commercial scale. The development and testing of MHD has shown its potential to be the most efficient, least costly, and cleanest way to burn coal. Test results have verified a greater than 99% removal of sulphur with a potential for greater than 60% efficiency. This development and testing, primarily funded by the U.S. Department of Energy (DOE), has progressed through the completion of its proof-of-concept (POC) phase at the 50 MWt Component Development and Integration Facility (CDIF) and 28 MWt Coal Fired Flow Facility (CFFF), thereby, providing the basis for demonstration and further commercial development and application of the technology. The conceptual design of a retrofit coal-fired MHD generating plant was originally completed by the MHD Development Corporation (MDC) under this Contract, DE-AC22-87PC79669. Thereafter, this concept was updated and changed to a stand-alone MHD demonstration facility and submitted by MDC to DOE in response to the fifth round of solicitations for Clean Coal Technology. Although not selected, that activity represents the major interest in commercialization by the developing industry and the type of demonstration that would be eventually necessary. This report updates the original executive summary of the conceptual design by incorporating the results of the POC program as well as MDC`s proposed Billings MHD Demonstration Project (BMDP) and outlines the steps necessary for commercialization.

NONE

1994-06-01T23:59:59.000Z

462

Consequence modeling for nuclear weapons probabilistic cost/benefit analyses of safety retrofits  

SciTech Connect (OSTI)

The consequence models used in former studies of costs and benefits of enhanced safety retrofits are considered for (1) fuel fires; (2) non-nuclear detonations; and, (3) unintended nuclear detonations. Estimates of consequences were made using a representative accident location, i.e., an assumed mixed suburban-rural site. We have explicitly quantified land- use impacts and human-health effects (e.g. , prompt fatalities, prompt injuries, latent cancer fatalities, low- levels of radiation exposure, and clean-up areas). Uncertainty in the wind direction is quantified and used in a Monte Carlo calculation to estimate a range of results for a fuel fire with uncertain respirable amounts of released Pu. We define a nuclear source term and discuss damage levels of concern. Ranges of damages are estimated by quantifying health impacts and property damages. We discuss our dispersal and prompt effects models in some detail. The models used to loft the Pu and fission products and their particle sizes are emphasized.

Harvey, T.F.; Peters, L.; Serduke, F.J.D.; Hall, C.; Stephens, D.R.

1998-01-01T23:59:59.000Z

463

Hydronic Heating Retrofits for Low-Rise Multifamily Buildings: Boiler Control Replacement and Monitoring  

SciTech Connect (OSTI)

The ARIES Collaborative, a U.S. Department of Energy Building America research team, partnered with NeighborWorks America affiliate Homeowners' Rehab Inc. (HRI) of Cambridge, Massachusetts, to study improvements to the central hydronic heating system in one of the nonprofit's housing developments. The heating controls in the three-building, 42-unit Columbia Cambridge Alliance for Spanish Tenants housing development were upgraded. Fuel use in the development was excessive compared to similar properties. A poorly insulated thermal envelope contributed to high energy bills, but adding wall insulation was not cost-effective or practical. The more cost-effective option was improving heating system efficiency. Efficient operation of the heating system faced several obstacles, including inflexible boiler controls and failed thermostatic radiator valves. Boiler controls were replaced with systems that offer temperature setbacks and one that controls heat based on apartment temperature in addition to outdoor temperature. Utility bill analysis shows that post-retrofit weather-normalized heating energy use was reduced by 10%-31% (average of 19%). Indoor temperature cutoff reduced boiler runtime (and therefore heating fuel consumption) by 28% in the one building in which it was implemented. Nearly all savings were obtained during night which had a lower indoor temperature cut off (68 degrees F) than day (73 degrees F). This implies that the outdoor reset curve was appropriately adjusted for this building for daytime operation. Nighttime setback of heating system supply water temperature had no discernable impact on boiler runtime or gas bills.

Dentz, J.; Henderson, H.; Varshney, K.

2014-09-01T23:59:59.000Z

464

Building America Best Practices Series, Volume 10: Retrofit Techniques and Technologies: Air Sealing  

SciTech Connect (OSTI)

This report was prepared by PNNL for the U.S. Department of Energy Building America Program. The report provides information to home owners who want to make their existing homes more energy efficient by sealing leaks in the building envelope (ceiling, walls, and floors) that let in drafts and let conditioned air escape. The report provides descriptions of 19 key areas of the home where air sealing can improve home performance and energy efficiency. The report includes suggestions on how to find a qualified weatherization or home performance contractor, what to expect in a home energy audit, opportune times for performing air sealing, and what safety and health concerns to be aware of. The report describes some basic building science concepts and topics related to air sealing including ventilation, diagnostic tools, and code requirements. The report will be available for free download from the DOE Building America website. It is a suitable consumer education tool for home performance and weatherization contractors to share with customers to describe the process and value of home energy retrofits.

Baechler, Michael C.; Gilbride, Theresa L.; Hefty, Marye G.; Cole, Pamala C.; Williamson, Jennifer L.; Love, Pat M.

2010-04-12T23:59:59.000Z

465

Manifold, bus support and coupling arrangement for solid oxide fuel cells  

DOE Patents [OSTI]

Individual, tubular solid oxide fuel cells (SOFCs) are assembled into bundles called a module within a housing, with a plurality of modules arranged end-to-end in a linear, stacked configuration called a string. A common set of piping comprised of a suitable high temperature resistant material (1) provides fuel and air to each module housing, (2) serves as electrically conducting buses, and (3) provides structural support for a string of SOFC modules. Ceramic collars are used to connect fuel and air inlet piping to each of the electrodes in an SOFC module and provide (1) electrical insulation for the current carrying bus bars and gas manifolds, (2) damping for the fuel and air inlet piping, and (3) proper spacing between the fuel and air inlet piping to prevent contact between these tubes and possible damage to the SOFC. 11 figs.

Parry, G.W.

1988-04-21T23:59:59.000Z

466

A superconducting cavity bus for single Nitrogen Vacancy defect centres in diamond  

E-Print Network [OSTI]

Circuit-QED has demonstrated very strong coupling between individual microwave photons trapped in a superconducting coplanar resonator and nearby superconducting qubits. In this work we show how, by designing a novel interconnect, one can strongly connect the superconducting resonator, via a magnetic interaction, to a small number (perhaps single), of electronic spins. By choosing the electronic spin to be within a Nitrogen Vacancy centre in diamond one can perform optical readout, polarization and control of this electron spin using microwave and radio frequency irradiation. More importantly, by utilising Nitrogen Vacancy centres with nearby 13C nuclei, using this interconnect, one has the potential build a quantum device where the nuclear spin qubits are connected over centimeter distances via the Nitrogen Vacancy electronic spins interacting through the superconducting bus.

J. Twamley; S. D. Barrett

2009-12-18T23:59:59.000Z

467

Peierls distorted chain as a quantum data bus for quantum state transfer  

E-Print Network [OSTI]

We systematically study the transfer of quantum state of electron spin as the flying qubit along a half-filled Peierls distorted tight-binding chain described by the Su-Schrieffer-Heeger (SSH) model, which behaves as a quantum data bus. This enables a novel physical mechanism for quantum communication with always-on interaction: the effective hopping of the spin carrier between sites $A$ and $B$ connected to two sites in this SSH chain can be induced by the quasi-excitations of the SSH model. As we prove, it is the Peierls energy gap of the SSH quasi-excitations that plays a crucial role to protect the robustness of the quantum state transfer process. Moreover, our observation also indicates that such a scheme can also be employed to explore the intrinsic property of the quantum system.

M. X. Huo; Ying Li; Z. Song; C. P. Sun

2006-06-01T23:59:59.000Z

468

Bay Ridge Gardens - Mixed Humid Affordable Multifamily Housing Deep Energy Retrofit: Annapolis, Maryland. Building America Case Study: Whole-House Solutions for Existing Homes (Fact Sheet)  

SciTech Connect (OSTI)

Under this project, Newport Partners (as part of the BA-PIRC research team) evaluated the installation, measured performance, and cost-effectiveness of efficiency upgrade measures for a tenant-in-place DER at the Bay Ridge multifamily (MF) development in Annapolis, Maryland. The design and construction phase of the Bay Ridge project was completed in August 2012. This report summarizes system commissioning, short-term test results, utility bill data analysis, and analysis of real-time data collected over a one-year period after the retrofit was complete. The Bay Ridge project is comprised of a "base scope" retrofit which was estimated to achieve a 30%+ savings (relative to pre-retrofit) on 186 apartments, and a "DER scope" which was estimated to achieve 50% savings (relative to pre-retrofit) on a 12-unit building. The base scope was applied to the entire apartment complex, except for one 12-unit building which underwent the DER scope. A wide range of efficiency measures was applied to pursue this savings target for the DER building, including improvements/replacements of mechanical equipment and distribution systems, appliances, lighting and lighting controls, the building envelope, hot water conservation measures, and resident education. The results of this research build upon the current body of knowledge of multifamily retrofits. Towards this end, the research team has collected and generated data on the selection of measures, their estimated performance, their measured performance, and risk factors and their impact on potential measures.

Not Available

2013-10-01T23:59:59.000Z

469

Development of an ultra-safe, ultra-low-emissions natural gas-fueled school bus: Phase 2, prototype hardware development  

SciTech Connect (OSTI)

This report summarizes work done on Phase 2, ``Prototype Hardware Development`` of Southwest Research Institute (SwRI) Project No. 03-6871, ``Development of an Ultra-Safe, Ultra-Low-Emissions Alternative-Fueled School Bus``. A prototype school bus was designed and constructed. This bus incorporated many new technologies to increase the safety of the bus passengers as well as pedestrians boarding and leaving the bus. These technologies emphasized increased visibility between the bus driver and pedestrians or vehicles, and included the use of high intensity discharge lighting, pedestrian and vehicle detection systems, and remote-mounted cameras. Passenger safety was also stressed, with the application of seat belts and improved emergency exits and lighting. A natural gas-fueled engine was developed for powering the bus. The development process focused primarily on improvements to the lean operation of the engine and control system advancements. The control system development included investigations into alternative control algorithms for steady-state and transient operation, various fuel metering devices, as well as new methods for wastegate control, knock and misfire detection, and catalyst monitoring. Both the vehicle and engine systems represent state-of-the-art technologies. Integration of the vehicle and engine is planned for the next phase of the project, followed by a demonstration test of the overall vehicle system.

Kubesh, J. [Southwest Research Inst., San Antonio, TX (United States)

1996-04-01T23:59:59.000Z

470

Stand-Off Furring in Deep Energy Retrofits, Syracuse, New York (Fact Sheet)  

SciTech Connect (OSTI)

IBACOS, in collaboration with GreenHomes America, was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions. This research investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and labor. The strategies included exterior wall insulation plus energy upgrades as needed in the attic, mechanical and ventilation systems, and basement band joist, walls, and floors. The work can be integrated with other home improvements such as siding or window replacement. This strategy minimizes physical connections to existing wall studs, encapsulates existing siding materials (including lead paint) with spray foam, and creates a vented rain screen assembly to promote drying. GreenHomes America applied construction details created by IBACOS to a test home. 2x4 framing members were attached to the wall at band joists and top plates using 'L' clips, with spray foam insulating the wall after framing was installed. Windows were installed simultaneously with the framing, including extension jambs. The use of clips in specific areas provided the best strength potential, and 'picture framing' the spray foam held the 2x4s in place. Short-term testing was performed at this house, with monitoring equipment installed for long-term testing. Testing measurements will be provided in a later report, as well as utility impact (before and after), costs (labor and materials), construction time, standard specifications, and analysis for the exterior wall insulation strategy.

Not Available

2014-05-01T23:59:59.000Z

471

DEVELOPMENT OF A LOW COST INFERENTIAL NATURAL GAS ENERGY FLOW RATE PROTOTYPE RETROFIT MODULE  

SciTech Connect (OSTI)

In 1998, Southwest Research Institute began a multi-year project to develop a working prototype instrument module for natural gas energy measurement. The module will be used to retrofit a natural gas custody transfer flow meter for energy measurement, at a cost an order of magnitude lower than a gas chromatograph. Development and evaluation of the prototype energy meter in 2002-2003 included: (1) refinement of the algorithm used to infer properties of the natural gas stream, such as heating value; (2) evaluation of potential sensing technologies for nitrogen content, improvements in carbon dioxide measurements, and improvements in ultrasonic measurement technology and signal processing for improved speed of sound measurements; (3) design, fabrication and testing of a new prototype energy meter module incorporating these algorithm and sensor refinements; and (4) laboratory and field performance tests of the original and modified energy meter modules. Field tests of the original energy meter module have provided results in close agreement with an onsite gas chromatograph. The original algorithm has also been tested at a field site as a stand-alone application using measurements from in situ instruments, and has demonstrated its usefulness as a diagnostic tool. The algorithm has been revised to use measurement technologies existing in the module to measure the gas stream at multiple states and infer nitrogen content. The instrumentation module has also been modified to incorporate recent improvements in CO{sub 2} and sound speed sensing technology. Laboratory testing of the upgraded module has identified additional testing needed to attain the target accuracy in sound speed measurements and heating value.

E. Kelner; D. George; T. Morrow; T. Owen; M. Nored; R. Burkey; A. Minachi

2005-05-01T23:59:59.000Z

472

Cost-Benefit Analysis of Flexibility Retrofits for Coal and Gas-Fueled Power Plants: August 2012 - December 2013  

SciTech Connect (OSTI)

High penetrations of wind and solar power plants can induce on/off cycling and ramping of fossil-fueled generators. This can lead to wear-and-tear costs and changes in emissions for fossil-fueled generators. Phase 2 of the Western Wind and Solar Integration Study (WWSIS-2) determined these costs and emissions and simulated grid operations to investigate the full impact of wind and solar on the fossil-fueled fleet. This report studies the costs and benefits of retrofitting existing units for improved operational flexibility (i.e., capability to turndown lower, start and stop faster, and ramp faster between load set-points).

Venkataraman, S.; Jordan, G.; O'Connor, M.; Kumar, N.; Lefton, S.; Lew, D.; Brinkman, G.; Palchak, D.; Cochran, J.

2013-12-01T23:59:59.000Z

473

Energy Implications of Retrofitting Retail Sector Rooftop Units with Stepped-Speed and Variable-Speed Functionality  

SciTech Connect (OSTI)

Commercial retailers understand that retrofitting constant-speed RTU fan motors with stepped- or variable-speed alternatives could save significant energy in most U.S. climate zones. However, they lack supporting data, both real-world and simulation based, on the cost effectiveness and climate zone-specific energy savings associated with this measure. Thus, building managers and engineers have been unable to present a compelling business case for fan motor upgrades to upper management. This study uses whole-building energy simulation to estimate the energy impact of this type of measure so retailers can determine its economic feasibility.

Studer, D.; Romero, R.; Herrmann, L.; Benne, K.

2012-04-01T23:59:59.000Z

474

Simulation of the Post-Retrofit Thermal Energy Use for the University Teaching Center (UTC) Building with the Use of Simplified System Models  

E-Print Network [OSTI]

ESL-TR-91/12-03 ENERGY SYSTEMS LABORATORY TECHNICAL REPORT REPRINTED WITH PERMISSION Simulation of the Post-Retrofit Thermal Energy Use for the University Teaching Center (UTC) Building with the Use of Simplified System Models Srinivas Katipamula, P.... Texas 77843 (409) 845-6402. or (409) 845-3251 INTRODUCTION Several state owned buildings with dual-duct constant volume (DDCV) systems have been retrofitted with energy efficient variable air volume systems (VAV) as part of the Texas LoanSTAR Program...

Katipamula, S.; Claridge, D. E.

1991-01-01T23:59:59.000Z

475

10 CFR 830 Major Modification Determination for the ATR Diesel Bus (E-3) and Switchgear Replacement  

SciTech Connect (OSTI)

Near term replacement of aging and obsolescent original ATR equipment has become important to ensure ATR capability in support of NE’s long term national missions. To that end, a mission needs statement has been prepared for a non-major system acquisition which is comprised of three interdependent subprojects. The first project, subject of this determination, will replace the existent diesel-electrical bus (E-3) and associated switchgear. More specifically, INL proposes transitioning ATR to 100% commercial power with appropriate emergency backup to include: • Provide commercial power as the normal source of power to the ATR loads currently supplied by diesel-electric power. • Provide backup power to the critical ATR loads in the event of a loss of commercial power. • Replace obsolescent critical ATR power distribution equipment, e.g., switchgear, transformers, motor control centers, distribution panels. Completion of this and two other age-related projects (primary coolant pump and motor replacement and emergency firewater injection system replacement) will resolve major age related operational issues plus make a significant contribution in sustaining the ATR safety and reliability profile. The major modification criteria evaluation of the project pre-conceptual design identified several issues make the project a major modification: 1. Evaluation Criteria #2 (Footprint change). The addition of a new PC-4 structure to the ATR Facility to house safety-related SSCs requires careful attention to maintaining adherence to applicable engineering and nuclear safety design criteria (e.g., structural qualification, fire suppression) to ensure no adverse impacts to the safety-related functions of the housed equipment. 2. Evaluation Criteria #3 (Change of existing process). The change to the strategy for providing continuous reliable power to the safety-related emergency coolant pumps requires careful attention and analysis to ensure it meets a project primary object to maintain or reduce CDF and does not negatively affect the efficacy of the currently approved strategy. 3. Evaluation Criteria #5 (Create the need for new or revised safety SSCs). The change to the strategy for providing continuous reliable power to the safety-related emergency coolant pumps, based on the pre-conceptual design, will require the addition of two quick start diesel generators, their associated power coordination/distribution controls, and a UPS to the list of safety-related SSCs. Similarly to item 1 above, the addition of these active SSCs to the list of safety-related SSCs and replacement of the E-3 bus requires careful attention to maintaining adherence to applicable engineering and nuclear safety design criteria (e.g., seismic qualification, isolation of redundant trains from common fault failures) to ensure no adverse impacts to the safety-related functions.

Noel Duckwtiz

2011-05-01T23:59:59.000Z

476

Hydrogen and Fuel Cell Transit Bus Evaluations: Joint Evaluation Plan for the U.S. Department of Energy and the Federal Transit Administration (Report and Appendix)  

SciTech Connect (OSTI)

This document describes the hydrogen transit bus evaluations performed by the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) and the U.S. Department of Transportation's Federal Transit Administration (FTA).

Eudy, L.; Chandler, K.

2008-05-01T23:59:59.000Z

477

Conceptual design of a coal-fired MHD retrofit plant. Topical report, Seed Regeneration System Study 2  

SciTech Connect (OSTI)

Westinghouse Advanced Energy Systems (WAES), through Contract No. DE-AC22-87PC79668 funded by US DOE/PETC, is conducting a conceptual design study to evaluate a coal-fired magnetohydrodynamic (MHD) retrofit of a utility plant of sufficient size to demonstrate the technical and future economic viability of an MHD system operating within an electric utility environment. The objective of this topical report is to document continuing seed regeneration system application studies and the definition of will system integration requirements for the Scholz MHD retrofit plant design. MHD power plants require the addition of a seeding material in the form of potassium to enhance the ionization of the high temperature combustion gas in the MHD channel. This process has an added environmental advantage compared to other types of coal-fired power plants in that the potassium combines with the naturally occurring sulfur in the coal to form a potassium sulfate flyash (K{sub 2}SO{sub 4}) which can be removed from the process by appropriate particulate control equipment. Up to 100% of the Sulfur in the coal can be removed by this process thereby providing environmentally clean power plant operation that is better than required by present and anticipated future New Source Performance Standards (NSPS).

Not Available

1992-11-01T23:59:59.000Z

478

The Energy DataBus: NREL's Open-Source Application for Large-Scale Energy Data Collection and Analysis  

DOE Data Explorer [Office of Scientific and Technical Information (OSTI)]

NREL’s Energy DataBus is used for tracking and analyzing energy use on its own campus. The system is applicable to other facilities—including anything from a single building to a large military base or college campus—or for other energy data management needs. Managing and minimizing energy consumption on a large campus is usually a difficult task for facility managers: There may be hundreds of energy meters spread across a campus, and the meter data are often recorded by hand. Even when data are captured electronically, there may be measurement issues or time periods that may not coincide. Making sense of this limited and often confusing data can be a challenge that makes the assessment of building performance a struggle for many facility managers. The Energy DataBus software was developed by NREL to address these issues on its own campus, but with an eye toward offering its software solutions to other facilities. Key features include the software's ability to store large amounts of data collected at high frequencies—NREL collects some of its energy data every second—and rich functionality to integrate this wide variety of data into a single database [copied from http://en.openei.org/wiki/NREL_Energy_DataBus].

479

Texas Hydrogen Highway Fuel Cell Hybrid Bus and Fueling Infrastructure Technology Showcase - Final Scientific/Technical Report  

SciTech Connect (OSTI)

The Texas Hydrogen Highway project has showcased a hydrogen fuel cell transit bus and hydrogen fueling infrastructure that was designed and built through previous support from various public and private sector entities. The aim of this project has been to increase awareness among transit agencies and other public entities on these transportation technologies, and to place such technologies into commercial applications, such as a public transit agency. The initial project concept developed in 2004 was to show that a skid-mounted, fully-integrated, factory-built and tested hydrogen fueling station could be used to simplify the design, and lower the cost of fueling infrastructure for fuel cell vehicles. The approach was to design, engineer, build, and test the integrated fueling station at the factory then install it at a site that offered educational and technical resources and provide an opportunity to showcase both the fueling station and advanced hydrogen vehicles. The two primary technology components include: Hydrogen Fueling Station: The hydrogen fueling infrastructure was designed and built by Gas Technology Institute primarily through a funding grant from the Texas Commission on Environmental Quality. It includes hydrogen production, clean-up, compression, storage, and dispensing. The station consists of a steam methane reformer, gas clean-up system, gas compressor and 48 kilograms of hydrogen storage capacity for dispensing at 5000 psig. The station is skid-mounted for easy installation and can be relocated if needed. It includes a dispenser that is designed to provide temperaturecompensated fills using a control algorithm. The total station daily capacity is approximately 50 kilograms. Fuel Cell Bus: The transit passenger bus built by Ebus, a company located in Downey, CA, was commissioned and acquired by GTI prior to this project. It is a fuel cell plug-in hybrid electric vehicle which is ADA compliant, has air conditioning sufficient for Texas operations, and regenerative braking for battery charging. It uses a 19.3 kW Ballard PEM fuel cell, will store 12.6 kg of hydrogen at 350 Bar, and includes a 60 kWh battery storage system. The objectives of the project included the following: (a) To advance commercialization of hydrogen-powered transit buses and supporting infrastructure; (b) To provide public outreach and education by showcasing the operation of a 22-foot fuel cell hybrid shuttle bus and Texas first hydrogen fueling infrastructure; and (c) To showcase operation of zero-emissions vehicle for potential transit applications. As mentioned above, the project successfully demonstrated an early vehicle technology, the Ebus plug-in hybrid fuel cell bus, and that success has led to the acquisition of a more advanced vehicle that can take advantage of the same fueling infrastructure. Needed hydrogen station improvements have been identified that will enhance the capabilities of the fueling infrastructure to serve the new bus and to meet the transit agency needs. Over the course of this project, public officials, local government staff, and transit operators were engaged in outreach and education activities that acquainted them with the real world operation of a fuel cell bus and fueling infrastructure. Transit staff members in the Dallas/Ft. Worth region were invited to a workshop in Arlington, Texas at the North Central Texas Council of Governments to participate in a workshop on hydrogen and fuel cells, and to see the fuel cell bus in operation. The bus was trucked to the meeting for this purpose so that participants could see and ride the bus. Austin area transit staff members visited the fueling site in Austin to be briefed on the bus and to participate in a fueling demonstration. This led to further meetings to determine how a fuel cell bus and fueling station could be deployed at Capital Metro Transit. Target urban regions that expressed additional interest during the project in response to the outreach meetings and showcase events include San Antonio and Austin, Texas. In summary, the project objectives wer

Hitchcock, David

2012-06-29T23:59:59.000Z

480

Manifold, bus support and coupling arrangement for solid oxide fuel cells  

DOE Patents [OSTI]

Individual, tubular solid oxide fuel cells (SOFCs) are assembled into bundles called a module within a housing, with a plurality of modules arranged end-to-end in a linear, stacked configuration called a string. A common set of piping comprised of a suitable high temperture resistant material (1) provides fuel and air to each module housing, (2) serves as electrically conducting buses, and (3) provides structural support for a string of SOFC modules. The piping thus forms a manfold for directing fuel and air to each module in a string and makes electrical contact with the module's anode and cathode to conduct the DC power generated by the SOFC. The piping also provides structureal support for each individual module and maintains each string of modules as a structurally integral unit for ensuring high strength in a large 3-dimensional array of SOFC modules. Ceramic collars are used to connect fuel and air inlet piping to each of the electrodes in an SOFC module and provide (1) electrical insulation for the current carrying bus bars and gas manifolds, (2) damping for the fuel and air inlet piping, and (3) proper spacing between the fuel and air inlet piping to prevent contact between these tubes and possible damage to the SOFC.

Parry, Gareth W. (East Windsor, CT)

1989-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "bus retrofit reimbursement" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

IMPROVEMENT TO PIPELINE COMPRESSOR ENGINE RELIABILITY THROUGH RETROFIT MICRO-PILOT IGNITION SYSTEM-PHASE I  

SciTech Connect (OSTI)

This report documents the first year's effort towards a 3-year program to develop micropilot ignition systems for existing pipeline compressor engines. In essence, all Phase I goals and objectives were met. We intend to proceed with the Phase II research plan, as set forth by the applicable Research Management Plan. The objective for Phase I was to demonstrate the feasibility of micropilot ignition for large bore, slow speed engines operating at low compression ratios. The primary elements of Micropilot Phase I were to develop a single-cylinder test chamber to study the injection of pilot fuel into a combustion cylinder and to develop, install and test a multi-cylinder micropilot ignition system for a 4-cylinder, natural gas test engine. In all, there were twelve (12) tasks defined and executed to support these two (2) primarily elements in a stepwise fashion. Task-specific approaches and results are documented in this report. Research activities for Micropilot Phase I were conducted with the understanding that the efforts are expected to result in a commercial product to capture and disseminate the efficiency and environmental benefits of this new technology. An extensive state-of-art review was conducted to leverage the existing body of knowledge of micropilot ignition with respect to retrofit applications. Additionally, commercially-available fuel injection products were identified and applied to the program where appropriate. This approach will minimize the overall time-to-market requirements, while meeting performance and cost criteria. The four-cylinder prototype data was encouraging for the micro-pilot ignition technology when compared to spark ignition. Initial testing results showed: (1) Brake specific fuel consumption of natural gas was improved from standard spark ignition across the map, 1% at full load and 5% at 70% load. (2) 0% misfires for all points on micropilot ignition. Fuel savings were most likely due to this percent misfire improvement. (3) THC (Total Hydrocarbon) emissions were improved significantly at light load, 38% at 70% load. (4) VOC (Volatile Organic Compounds) emissions were improved above 80% load. (5) Coefficient of Variance for the IMEP (Indicated Mean Effective Pressure) was significantly less at lower loads, 76% less at 70%. These preliminary results will be substantiated and enhanced during Phase II of the Micropilot Ignition program.

Ted Bestor

2003-03-04T23:59:59.000Z

482

11th European Conference on Earthquake Engineering 1998 Balkema, Rotterdam, ISBN 90 5410 982 3 Seismic retrofit of non-ductile concrete and masonry walls by steel-  

E-Print Network [OSTI]

Seismic retrofit of non-ductile concrete and masonry walls by steel- strips bracing Mustafa Taghdi, Michel, concrete, non-ductile, steel, strips, ductility, hysteretic behavior ABSTRACT: Four concrete block masonry from each pair was retro- fitted using a steel strip system. The steel strip system consists

Bruneau, Michel

483

Objective: Determine the energy use of two greenhouse insulation technologies (a bubble insulation system and an energy/shade screen) retrofitted into plastic covered greenhouses, and compare the  

E-Print Network [OSTI]

compared to the unimproved house. The bubble insulation system was more energy efficient than the other two roughly twice the savings stated above. Novel Approaches to Improve Energy Efficiency in Northern New system and an energy/shade screen) retrofitted into plastic covered greenhouses, and compare

Vermont, University of

484

District heating and cooling systems for communities through power plant retrofit distribution network. Phase 2. Final report, 1 March 1980-31 January 1984. Volume VII. Appendix C  

SciTech Connect (OSTI)

This volume contains: Hudson No. 2 Limited Retrofit Cost Estimates provided by Stone and Webster Engineering Corp. (SWEC); backup data and basis of estimate for SWEC Heater Plant and Gas Turbine Plant (Kearny No. 12) cost estimates; and Appendices - Analysis of Relevant Tax Laws.

Not Available

1984-01-31T23:59:59.000Z

485

District heating and cooling systems for communities through power plant retrofit distribution network. Phase 2. Final report, March 1, 1980-January 31, 1984. Volume IV  

SciTech Connect (OSTI)

This volume contains the following: discussion of cost estimating methodology, detailed cost estimates of Hudson No. 2 retrofit, intermediate thermal plant (Kearny No. 12) and local heater plants; transmission and distribution cost estimate; landfill gas cost estimate; staged development scenarios; economic evaluation; fuel use impact; air quality impact; and alternatives to district heating.

Not Available

1984-01-31T23:59:59.000Z

486

Low NO{sub x}/SO{sub x} Burner retrofit for utility cyclone boilers. Quarterly technical progress report, June--September 1990  

SciTech Connect (OSTI)

The objective of this project is to demonstrate the LNS Burner as retrofitted to the host cyclone boiler for effective low-cost control of NO{sub x} and SO{sub x} emissions while firing a bituminous coal. The LNS Burner employs a simple, innovative combustion process to burn pulverized coal at high temperatures and provides effective, low-cost control of sulfur dioxide (SO{sub 2}) and nitrogen oxides (NO{sub x}) emissions. The coal ash contains sulfur and is removed in the form of molten slag and flyash. Cyclone-fired boiler units are typically older units firing high-sulfur bituminous coals at very high temperatures which results in very high NO{sub x} and SO{sub x} emissions. The addition of conventional emission control equipment, such as wet scrubbers, to these older cyclone units in order to meet current and future environmental regulations is generally not economic. Further, the units are generally not compatible with low sulfur coal switching for S0{sub 2} control or selective catalytic reduction technologies for NO{sub x} control. Because the LNS Burner operates at the same very high temperatures as a typical cyclone boiler and produces a similar slag product, it may offer a viable retrofit option for cyclone boiler emission control. This was confirmed by the Cyclone Boiler Retrofit Feasibility Study carried out by TransAlta and an Operating Committee formed of cyclone boiler owners in 1989. An existing utility cyclone boiler, was then selected for the evaluation of the cost and performance study. It was concluded that the LNS Burner retrofit would be a cost-effective option for control of cyclone boiler emissions. A full-scale demonstration of the LNS Burner retrofit was selected in October 1988 as part of the DOE`s Clean Coal Technology Program Round II.

Not Available

1990-12-31T23:59:59.000Z

487

Simplified Space Conditioning in Low-Load Homes: Results from the Fresno, California, Retrofit Unoccupied Test House  

SciTech Connect (OSTI)

Field testing was performed in a retrofit unoccupied test house in Fresno, California. Three air-based heating, ventilation, and air conditioning (HVAC) distribution systems -- a typical airflow ducted system to the bedrooms, a low airflow ducted system to the bedrooms, and a system with no ductwork to the bedrooms -- were evaluated during heating, cooling, and midseason conditions. The relative ability of each of the three systems was assessed with respect to relevant Air Conditioning Contractors of America (ACCA) and ASHRAE standards for house temperature uniformity and stability, respectively. Computational fluid dynamics (CFD) modeling also was performed and refined based on comparison to field test results to determine the air flow rate into the bedrooms of over-door and bottom-of-door air transfer grilles.

Stecher, D.; Poerschke, A.

2014-02-01T23:59:59.000Z

488

RM12-2703 Advanced Rooftop Unit Control Retrofit Kit Field Demonstration: Hawaii and Guam Energy Improvement Technology Demonstration Project  

SciTech Connect (OSTI)

As part of its overall strategy to meet its energy goals, the Naval Facilities Engineering Command (NAVFAC) partnered with U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to rapidly demonstrate and deploy cost-effective renewable energy and energy efficiency technologies. This was one of several demonstrations of new and underutilized commercial energy efficiency technologies. The consistent year-round demand for air conditioning and dehumidification in Hawaii provides an advantageous demonstration location for advanced rooftop control (ARC) retrofit kits to packaged rooftop units (RTUs). This report summarizes the field demonstration of ARCs installed on nine RTUs serving a 70,000-ft2 exchange store (large retail) and two RTUs, each serving small office buildings located on Joint Base Pearl Harbor-Hickam (JBPHH).

Doebber, I.; Dean, J.; Dominick, J.; Holland, G.

2014-03-01T23:59:59.000Z

489

SPRAY FOAM IN ACCESSIBLE SPACES:BEST PRACTICES AND CASE STUDIES FOR RETROFIT IN MIXED-HUMID CLIMATE  

SciTech Connect (OSTI)

Heating and cooling the house is one of the homeowners major expenses. Reducing these costs, saving energy, and creating a healthier, more comfortable indoor environment are good reasons to consider improving the building thermal envelope. Improvements usually consider increasing the amount of insulation, reducing the infiltration of outside air, and controlling moisture in existing buildings. This report describes the use of spray foam materials to insulate, seal, and control moisture. This discussion is limited to treating areas that are accessible. What is accessible, however, can vary depending on the type of renovation. If the building has been gutted or exterior surfaces removed, there are more options. This report will look at areas to consider for spray foam application and discuss the types of spray foams available and their uses. A number of case studies are presented to show the effectiveness of this retrofit in existing houses based on performance data.

Christian, Jeffrey E [ORNL; Gant, Kathy [Oak Ridge National Laboratory (ORNL)

2013-12-01T23:59:59.000Z

490

Robust quantum gates and a bus architecture for quantum computing with rare-earth-ion doped crystals  

E-Print Network [OSTI]

We present a composite pulse controlled phase gate which together with a bus architecture improves the feasibility of a recent quantum computing proposal based on rare-earth-ion doped crystals. Our proposed gate operation is tolerant to variations between ions of coupling strengths, pulse lengths, and frequency shifts, and it achieves worst case fidelities above 0.999 with relative variations in coupling strength as high as 10% and frequency shifts up to several percent of the resonant Rabi frequency of the laser used to implement the gate. We outline an experiment to demonstrate the creation and detection of maximally entangled states in the system.

Janus Wesenberg; Klaus Moelmer

2003-01-09T23:59:59.000Z

491

U.S. Department of Energy NEPA Categorical Exclusion Determination...  

Broader source: Energy.gov (indexed) [DOE]

bus benches; 3) retrofits to city buildings (includes installing insulation, replacing HVAC systems, energy efficient windows and doors, lighting systems, and pumps and motors;...

492

--No Title--  

Broader source: Energy.gov (indexed) [DOE]

Energy Efficiency and Conservation Block Grants Owensboro's Window, Bus Shelter, HVAC Retrofits Owensboro Kentucky Nov 9, 2009 Gary Hartman Print Form for Records Submit to Website...

493

Research development and demonstration of a fuel cell/battery powered bus system. Interim report, August 1, 1991--April 30, 1992  

SciTech Connect (OSTI)

This report describes the progress in the Georgetown University research, development and demonstration project of a fuel cell/battery powered bus system. The topics addressed in the report include vehicle design and application analysis, technology transfer activities, coordination and monitoring of system design and integration contractor, application of fuel cells to other vehicles, current problems, work planned, and manpower, cost and schedule reports.

Romano, S.; Wimmer, R.

1992-04-30T23:59:59.000Z

494

MILP islanding of power networks by bus splitting P. A. Trodden, W. A. Bukhsh, A. Grothey, and K. I. M. McKinnon  

E-Print Network [OSTI]

]­[7]. A more recently occurring factor is increased penetration of variable distributed generation, notably into `viable' islands. Motives for splitting range from islands balanced in load and generation to electroMILP islanding of power networks by bus splitting P. A. Trodden, W. A. Bukhsh, A. Grothey, and K. I

Grothey, Andreas

495

STAT565: APPLIED TIME SERIES ANALYSIS 16:960:565 SPRING 2014, MONDAY 6:40-9:30 PM, ARC 107 BUS  

E-Print Network [OSTI]

STAT565: APPLIED TIME SERIES ANALYSIS 16:960:565 SPRING 2014, MONDAY 6:40-9:30 PM, ARC 107 BUS 1 or by appointment · Email: hxiao@stat.rutgers.edu · Prerequisite. First graduate level courses in mathematical, by Ruey S. Tsay. Wiley, 2010, 3rd. Full text available from MyiLibrary http://lib.myilibrary.com/Open.aspx?id

Shepp, Larry

496

Evaluation of a Current Source Active Power Filter to Reduce the DC Bus Capacitor in a Hybrid Electric Vehicle Traction Drive  

E-Print Network [OSTI]

system, additional heat, audible noise, mechanical stress, and vibration [1]. DC bus harmonic current- powered three-phase inverter is used to drive the traction motor. Due to the switching behavior combustion engine, electric motor, and energy storage device (for example, batteries and ultracapacitors

Tolbert, Leon M.

497

Abstract--Layout of the conductor material in the dc bus of a photovoltaic (PV) array to lower first cost and ohmic losses is  

E-Print Network [OSTI]

its operating economy by reducing installed cost and ohmic losses. Index Terms--Photovoltaic systemsAbstract--Layout of the conductor material in the dc bus of a photovoltaic (PV) array to lower first cost and ohmic losses is reviewed. Six PV materials are characterized for their voltage swings

King, Roger

498

Dynamic performance of static and synchronous compensators at an HVDC inverter bus in a very weak AC system  

SciTech Connect (OSTI)

This paper discusses the performance of dynamic voltage control devices at the inverters of very weak ac systems. The types of compensation considered are: (a) static var compensator (SVC), (b) synchronous compensator (SC), (c) a mix of the two and (d) fixed capacitors. Although the primary purpose of these compensators is to control voltage at the ac bus, their dynamic performance during system disturbances is a very important factor. The investigation includes the behavior of the various voltage control options under ac and dc disturbances. The paper shows that the SVC has the fastest response for load rejection type of overvoltages, but can cause serious problems with recovery during undervoltages caused by single phase faults. The CIGRE benchmark model for HVdc control studies has been modified and used in this study. In particular the effect of local load has been included.

Nayak, O.B.; Gole, A.M. (Univ. of Manitoba, Winnipeg (Canada)); Chapman, D.G.; Davies, J.B. (Manitoba Hydro, Winnipeg (Canada))

1994-08-01T23:59:59.000Z

499

Health Reimbursement Arrangement (HRA)  

E-Print Network [OSTI]

, LLC ("EIS"). EIS is a Utah resident insurance agency. EIS is also licensed as a non-resident insurance

Pennycook, Steve

500

ADVANCED FLUE GAS CONDITIONING AS A RETROFIT UPGRADE TO ENHANCE PM COLLECTION FROM COAL-FIRED ELECTRIC UTILITY BOILERS  

SciTech Connect (OSTI)

The U.S. Department of Energy and ADA Environmental Solutions are engaged in a project to develop commercial flue gas conditioning additives. The objective is to develop conditioning agents that can help improve particulate control performance of smaller or under-sized electrostatic precipitators on utility coal-fired boilers. The new chemicals will be used to control both the electrical resistivity and the adhesion or cohesivity of the fly ash. There is a need to provide cost-effective and safer alternatives to traditional flue gas conditioning with SO{sub 3} and ammonia. During this reporting quarter, performance testing of flue gas conditioning was completed at the PacifiCorp Jim Bridger Power Plant. The product tested, ADA-43, was a combination resistivity modifier with cohesivity polymers. The product was effective as a flue gas conditioner. However, ongoing problems with in-duct deposition resulting from the flue gas conditioning were not entirely resolved. Primarily these problems were the result of difficulties encountered with retrofit of an existing spray humidification system. Eventually it proved necessary to replace all of the original injection lances and to manually bypass the PLC-based air/liquid feed control. This yielded substantial improvement in spray atomization and system reliability. However, the plant opted not to install a permanent system. Also in this quarter, preparations continued for a test of the cohesivity additives at the American Electric Power Conesville Plant, Unit 3. This plant fires a bituminous coal and has opacity and particulate emissions performance issues related to fly ash re-entrainment. Ammonia conditioning is employed here on one unit, but there is interest in liquid cohesivity additives as a safer alternative.

Kenneth E. Baldrey

2002-07-01T23:59:59.000Z