Powered by Deep Web Technologies
Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Development of Building Automation and Control Systems  

E-Print Network [OSTI]

A design flow for building automation and control systems,’’Development of Building Automation and Control Systems Yangdesign of the build- ing automation system (including the

Yang, Yang; Zhu, Qi; Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

2

Small- and Medium-Size Building Automation and Control System...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Emerging...

3

Towards Automated Service Composition using Policy Ontology in Building Automation System  

E-Print Network [OSTI]

Towards Automated Service Composition using Policy Ontology in Building Automation System Son N.crespi}@it-sudparis.eu Abstract--Automated service composition is critical for suc- cessfully implementing Building Automation-service composition; semantic web; policy; ontol- ogy; building automation system; I. INTRODUCTION In building

Paris-Sud XI, Université de

4

Building automation systems (BAS) are concerned with control and monitoring of buildings, while aiming to  

E-Print Network [OSTI]

Building automation systems (BAS) are concerned with control and monitoring of buildings, while alarm systems or physical access control), · control the climate in the building/supervise and control operating and energy costs Realization and Experiences with a Low-Cost Building Automation Security Testbed

Behnke, Sven

5

Integration of Real-Time Data Into Building Automation Systems  

SciTech Connect (OSTI)

The project goal was to investigate the possibility of using predictive real-time information from the Internet as an input to building management system algorithms. The objectives were to identify the types of information most valuable to commercial and residential building owners, managers, and system designers. To comprehensively investigate and document currently available electronic real-time information suitable for use in building management systems. Verify the reliability of the information and recommend accreditation methods for data and providers. Assess methodologies to automatically retrieve and utilize the information. Characterize equipment required to implement automated integration. Demonstrate the feasibility and benefits of using the information in building management systems. Identify evolutionary control strategies.

Mark J. Stunder; Perry Sebastian; Brenda A. Chube; Michael D. Koontz

2003-04-16T23:59:59.000Z

6

Development of Building Automation and Control Systems  

E-Print Network [OSTI]

is not suitable for low energy buildings that requirelow energy solutions such as natural ventilation and active facade. In this BUILDINGlow energy green buildingsVzero energy in the ideal caseVis very challenging. There are examples of zero energy buildings

Yang, Yang; Zhu, Qi; Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

7

Final Draft Building Automation Systems Design and Construction Standards October 3rd  

E-Print Network [OSTI]

Final Draft Building Automation Systems Design and Construction Standards October 3rd , 2013 1 Building Automation System Design and Construction Standards University of Rochester Utilities and Energy Automation Systems Design and Construction Standards October 3rd , 2013 2 University of Rochester Building

Portman, Douglas

8

Use of Building Automation System Trend Data for Inputs Generation in Bottom-Up Simulation Calibration  

E-Print Network [OSTI]

for analysis and use in simulation is very large. This paper explores automating the process of generating inputs from Building Automation System (BAS) trend data for use in building simulation software. A proof-of-concept prototype called the Automatic...

Zibin, N. F.; Zmeureanu, R. G.; Love, J. A.

2013-01-01T23:59:59.000Z

9

A DISTRIBUTED INTELLIGENT AUTOMATED DEMAND RESPONSE BUILDING MANAGEMENT SYSTEM  

SciTech Connect (OSTI)

The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Response (openADR), Auto-­?Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-­?to-­?building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov-­? March) and a steam absorption chiller for use in the warm months (April-­?October). Lighting in the open office areas is provided by direct-­?indirect luminaries with Building Management System-­?based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load during the study period was 1175 kW. Several new tools facilitated this work, such as the Smart Energy Box, the distributed load controller or Energy Information Gateway, the web-­?based DR controller (dubbed the Central Load-­?Shed Coordinator or CLSC), and the Demand Response Capacity Assessment & Operation Assistance Tool (DRCAOT). In addition, an innovative data aggregator called sMAP (simple Measurement and Actuation Profile) allowed data from different sources collected in a compact form and facilitated detailed analysis of the building systems operation. A smart phone application (RAP or Rapid Audit Protocol) facilitated an inventory of the building’s plug loads. Carbon dioxide sensors located in conference rooms and classrooms allowed demand controlled ventilation. The extensive submetering and nimble access to this data provided great insight into the details of the building operation as well as quick diagnostics and analyses of tests. For example, students discovered a short-­?cycling chiller, a stuck damper, and a leaking cooling coil in the first field tests. For our final field tests, we were able to see how each zone was affected by the DR strategies (e.g., the offices on the 7th floor grew very warm quickly) and fine-­?tune the strategies accordingly.

Auslander, David; Culler, David; Wright, Paul; Lu, Yan; Piette, Mary

2013-12-30T23:59:59.000Z

10

Methods for Automated and Continuous Commissioning of Building Systems  

SciTech Connect (OSTI)

Avoidance of poorly installed HVAC systems is best accomplished at the close of construction by having a building and its systems put ''through their paces'' with a well conducted commissioning process. This research project focused on developing key components to enable the development of tools that will automatically detect and correct equipment operating problems, thus providing continuous and automatic commissioning of the HVAC systems throughout the life of a facility. A study of pervasive operating problems reveled the following would most benefit from an automated and continuous commissioning process: (1) faulty economizer operation; (2) malfunctioning sensors; (3) malfunctioning valves and dampers, and (4) access to project design data. Methodologies for detecting system operation faults in these areas were developed and validated in ''bare-bones'' forms within standard software such as spreadsheets, databases, statistical or mathematical packages. Demonstrations included flow diagrams and simplified mock-up applications. Techniques to manage data were demonstrated by illustrating how test forms could be populated with original design information and the recommended sequence of operation for equipment systems. Proposed tools would use measured data, design data, and equipment operating parameters to diagnosis system problems. Steps for future research are suggested to help more toward practical application of automated commissioning and its high potential to improve equipment availability, increase occupant comfort, and extend the life of system equipment.

Larry Luskay; Michael Brambley; Srinivas Katipamula

2003-04-30T23:59:59.000Z

11

A Distributed Facilities Automation System For IBM Buildings  

E-Print Network [OSTI]

to the host would be via an IBM-supplied local communications network protocol. Remote appli cations would include process control, security, energy manage ment, facilities automation or any other automation application. The remote systems... of these areas which are affected are: - HVAC - Chemical Processes Control - Utilities Generation - Tank Farm Monitoring Resource Management - Solvent Supply and Recovery Systems - DI Water Distribution - Sewage and Waste Treatment Plant Control...

Houle, W. D. Sr.

12

Initial and Continuous Commissioning of Building Automation and Control Systems (BACS) -Preview EN ISO 16484-  

E-Print Network [OSTI]

8th International Conference for Enhanced Building Operations - ICEBO?08 Conference Center of the Federal Ministry of Economics and Technology Berlin, October 20 - 22, 2008 Dipl.-Ing. Hans R. Kranz VDI HAK Consulting Enzstrasse 10 76694... Forst 0 04 91 72/ 2 92 60 21 hans@kranz.com INITIAL AND CONTINUOUS COMMISSIONING OF BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PREVIEW EN ISO 16484 - Did you ever think about: ?why are our buildings so dumb?? The simple answer might be...

Kranz, H. R.

2008-01-01T23:59:59.000Z

13

Human-Machine Interface in Building Automation Systems  

E-Print Network [OSTI]

--the JC/SS/40--whose design has responded to these operator needs, will be shown. User Acceptance The user acceptance of an on-line system can be related to a phenomenon called "subject-object role reversal". This means that operators, because... requirements dependent upon the their skill and the frequency of their access to the system. The JC/SS/40 has responded to this situation by breaking up the entry method into three modes. The AID mode is used by an inexperienced operator...

Sobczak, N. L.

1981-01-01T23:59:59.000Z

14

Participation through Automation: Fully Automated Critical Peak Pricing in Commercial Buildings  

E-Print Network [OSTI]

Figure 2. Demand Response Automation Server and BuildingII system to notify the Automation Server of an up comingoccurs day-ahead). 2. The Automation Server posts two pieces

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

2006-01-01T23:59:59.000Z

15

Sacks R. (1998), `Issues in the Development and Implementation of a Building Project Model for an Automated Building System', International Journal of Construction Information Technology, Salford University, Salford  

E-Print Network [OSTI]

designed to support computer-based integration between various construction applications, it is proposed of an Automated, Computer Integrated Building Realization System is to automatically generate all of the information required for the design, planning and execution of a building project. The project model forms

Sacks, Rafael

16

Open Automated Demand Response for Small Commerical Buildings  

E-Print Network [OSTI]

Demand  Response for Small Commercial Buildings.   CEC?500?automated demand response  For small commercial buildings, AUTOMATED DEMAND RESPONSE FOR SMALL COMMERCIAL BUILDINGS

Dudley, June Han

2009-01-01T23:59:59.000Z

17

Building Automation and Controls Systems: Integrated Room Control for Personalized Comfort and Increased ROI  

E-Print Network [OSTI]

Smart Room Control ESL-IC-14-09-05 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Agenda ? Room Control fundamentals and evolution ? Challenges ? The Smart Room Control... for Enhanced Building Operations, Beijing, China, September 14-17, 2014 The Solution? ESL-IC-14-09-05 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Smart Room Control ? End-to-end system...

Gill, D.

2014-01-01T23:59:59.000Z

18

Field Demonstration of Automated Demand Response for Both Winter and Summer Events in Large Buildings in the Pacific Northwest  

E-Print Network [OSTI]

automated demand response systems in large buildings in theBuilding Control Strategies and Techniques for Demand Response,buildings were able to provide significant demand response

Piette, Mary Ann

2014-01-01T23:59:59.000Z

19

Experiences of Using Models and Information of Building Automation System in Commissioning  

E-Print Network [OSTI]

Simulation programs are widely used in the design of heating and cooling devices. However, modeling of the whole building with simulation programs is exceptional at least in Finland. We have built and utilized whole building models in a...

Keranen, H.; Kalema, T.; Pesonen, A.

2004-01-01T23:59:59.000Z

20

Participation through Automation: Fully Automated Critical Peak Pricing in Commercial Buildings  

E-Print Network [OSTI]

Figure 2. Demand Response Automation Server and BuildingDemand Response Control Strategies in Commercial Buildings,X X Example of Demand Response from an Office Building This

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Using personal computers for enhanced presence detection in building automation  

E-Print Network [OSTI]

.ini.unizh.ch/~tobi Effective building automation depends on reliable sensors, but the usual passive infrared (PIR) sensors operating system. Our PC client software presently has 20 users. The combination of PIR and PC sensors (h) Day PC Client running PIR Presence PC Presence PC Client running PIR Presence PC Presence Daytime

Delbruck, Tobi

22

Open Automated Demand Response for Small Commerical Buildings  

SciTech Connect (OSTI)

This report characterizes small commercial buildings by market segments, systems and end-uses; develops a framework for identifying demand response (DR) enabling technologies and communication means; and reports on the design and development of a low-cost OpenADR enabling technology that delivers demand reductions as a percentage of the total predicted building peak electric demand. The results show that small offices, restaurants and retail buildings are the major contributors making up over one third of the small commercial peak demand. The majority of the small commercial buildings in California are located in southern inland areas and the central valley. Single-zone packaged units with manual and programmable thermostat controls make up the majority of heating ventilation and air conditioning (HVAC) systems for small commercial buildings with less than 200 kW peak electric demand. Fluorescent tubes with magnetic ballast and manual controls dominate this customer group's lighting systems. There are various ways, each with its pros and cons for a particular application, to communicate with these systems and three methods to enable automated DR in small commercial buildings using the Open Automated Demand Response (or OpenADR) communications infrastructure. Development of DR strategies must consider building characteristics, such as weather sensitivity and load variability, as well as system design (i.e. under-sizing, under-lighting, over-sizing, etc). Finally, field tests show that requesting demand reductions as a percentage of the total building predicted peak electric demand is feasible using the OpenADR infrastructure.

Dudley, June Han; Piette, Mary Ann; Koch, Ed; Hennage, Dan

2009-05-01T23:59:59.000Z

23

Automated Continuous Commissioning of Commercial Buildings  

E-Print Network [OSTI]

Building 7230, the existing Siemens APOGEE TM control system14], interfaces with the Siemens BACnet server in order to17, there are five devices (Siemens MEC controllers), with

Bailey, Trevor

2013-01-01T23:59:59.000Z

24

A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building  

E-Print Network [OSTI]

with a sound, integrated building design, and then to paydesign, efficient technology and properly integrated buildingintegrated whole building systems Achieving a high level of building performance is the result of careful, informed design and execution so that building

2013-01-01T23:59:59.000Z

25

European Union Energy Performance of Building Directive and the Impact of Building Automation on Energy Efficiency  

E-Print Network [OSTI]

Gubelstrasse 22 CH-6301 Zug 00 41 41/ 7 24 55 60 wirth.ulrich@siemens.com European Union Energy Performance of Buildings Directive and The impact of Building Automation on Energy Efficiency Buildings account for 40 percent of global energy... building automation and control and technical building management based on the same may provide a demonstrable contribution to EU savings goals of 20 percent by 2020. The goal of European Directive 2002/91/EC on the total energy efficiency of buildings...

Wirth, U.

2008-01-01T23:59:59.000Z

26

Findings from Seven Years of Field Performance Data for Automated Demand Response in Commercial Buildings  

E-Print Network [OSTI]

Automated Demand Response for Small Commercial Buildings. ”Demand Response Strategies and Commissioning Commercial Buildingfor Automated Demand Response in Commercial Buildings Sila

Kiliccote, Sila

2010-01-01T23:59:59.000Z

27

Automated Continuous Commissioning of Commercial Buildings  

E-Print Network [OSTI]

in building total energy consumption and related costs (overin building total energy consumption and related costs (overin building total energy consumption and related costs (over

Bailey, Trevor

2013-01-01T23:59:59.000Z

28

Automated Continuous Commissioning of Commercial Buildings  

E-Print Network [OSTI]

P. “Real Time Model-based Energy Diagnostics in Buildings. ”Proc. Building Simulation ’11, Sydney, Australia, Novemberhttp://www.eere.energy.gov/buildings/energyplus/. 7. http://

Bailey, Trevor

2013-01-01T23:59:59.000Z

29

Automated Continuous Commissioning of Commercial Buildings  

E-Print Network [OSTI]

electricity consumption ..the total building electricity consumption between measured87 Figure 49 Total electricity consumption end use breakdown

Bailey, Trevor

2013-01-01T23:59:59.000Z

30

Automate and accelerate build and release processes IBM Rational Build Forge  

E-Print Network [OSTI]

n n n n n n n Automate and accelerate build and release processes IBM Rational Build Forge in place today Accelerate build and release cycles through iterative develop- ment, parallel processes and efficient use of hardware Improve product quality through consistent, repeatable processes and early

31

Installation and Commissioning Automated Demand Response Systems  

E-Print Network [OSTI]

Demand Response Systems National Conference on BuildingDemand Response Systems National Conference on BuildingDemand Response Systems National Conference on Building

Kiliccote, Sila; Global Energy Partners; Pacific Gas and Electric Company

2008-01-01T23:59:59.000Z

32

Using Building Control System for Commissioning  

E-Print Network [OSTI]

France-USA Finland France Japan USA Netherlands Main End-Users BOp MC ES BD BOp BI BOp MC ES BOp BOw BS BOp ES BOp MC ES MI CA BOp MC ES BOp Type building Large commercial buildings Any types Medium and large commercial... 34, VTT, Finland, ISBN 951-38-5725-5. [4] Castro, N.S., Galler, M. A., Bushby, S. T. ?A Test Shell for Developing Automated Commissioning Tools for BACnet Systems? National Conference on Building Commissioning, 2003. ...

Vaezi-Nejad, H.; Salsbury, T.; Choiniere, D.

2004-01-01T23:59:59.000Z

33

Automated Comparison of Building Energy Simulation Engines (Presentation)  

SciTech Connect (OSTI)

This presentation describes the BEopt comparative test suite, which is a tool that facilitates the automated comparison of building energy simulation engines. It also demonstrates how the test suite is improving the accuracy of building energy simulation programs. Building energy simulation programs inform energy efficient design for new homes and energy efficient upgrades for existing homes. Stakeholders rely on accurate predictions from simulation programs. Previous research indicates that software tends to over-predict energy usage for poorly-insulated leaky homes. NREL is identifying, investigating, and resolving software inaccuracy issues. Comparative software testing is one method of many that NREL uses to identify potential software issues.

Polly, B.; Horowitz, S.; Booten, B.; Kruis, N.; Christensen, C.

2012-08-01T23:59:59.000Z

34

A DISTRIBUTED AUTOMATION SYSTEM FOR ELECTROPHYSICAL INSTALLATIONS  

E-Print Network [OSTI]

A DISTRIBUTED AUTOMATION SYSTEM FOR ELECTROPHYSICAL INSTALLATIONS V.R. Kozak Budker Institute There was designed a set of devices for automation systems of physical installations. On this basis approach. KEY WORDS Automation, systems, applications, CANBUS, embedded, controller. 1. Introduction Budker

Kozak, Victor R.

35

Automated Continuous Commissioning of Commercial Buildings  

E-Print Network [OSTI]

and Atmospheric Administration PACRAT: Performance andbased technologies such as PACRAT [15], this system uses a

Bailey, Trevor

2013-01-01T23:59:59.000Z

36

Field Test Results of Automated Demand Response in a Large Office Building  

E-Print Network [OSTI]

Building Control Strategies and Techniques for Demand Response,Automated Demand Response in a Large Office Building JunqiaoDemand Response Load Impacts: Evaluation of Baseline Load Models for Non-Residential Building

Han, Junqiao

2008-01-01T23:59:59.000Z

37

Open Automated Demand Response for Small Commerical Buildings  

E-Print Network [OSTI]

of Fully Automated Demand  Response in Large Facilities.  Fully Automated Demand Response Tests in Large Facilities.  Open Automated  Demand Response Communication Standards: 

Dudley, June Han

2009-01-01T23:59:59.000Z

38

Installation and Commissioning Automated Demand Response Systems  

SciTech Connect (OSTI)

Demand Response (DR) can be defined as actions taken to reduce electric loads when contingencies, such as emergencies and congestion, occur that threaten supply-demand balance, or market conditions raise supply costs. California utilities have offered price and reliability DR based programs to customers to help reduce electric peak demand. The lack of knowledge about the DR programs and how to develop and implement DR control strategies is a barrier to participation in DR programs, as is the lack of automation of DR systems. Most DR activities are manual and require people to first receive notifications, and then act on the information to execute DR strategies. Levels of automation in DR can be defined as follows. Manual Demand Response involves a labor-intensive approach such as manually turning off or changing comfort set points at each equipment switch or controller. Semi-Automated Demand Response involves a pre-programmed demand response strategy initiated by a person via centralized control system. Fully-Automated Demand Response does not involve human intervention, but is initiated at a home, building, or facility through receipt of an external communications signal. The receipt of the external signal initiates pre-programmed demand response strategies. We refer to this as Auto-DR (Piette et. al. 2005). Auto-DR for commercial and industrial facilities can be defined as fully automated DR initiated by a signal from a utility or other appropriate entity and that provides fully-automated connectivity to customer end-use control strategies. One important concept in Auto-DR is that a homeowner or facility manager should be able to 'opt out' or 'override' a DR event if the event comes at time when the reduction in end-use services is not desirable. Therefore, Auto-DR is not handing over total control of the equipment or the facility to the utility but simply allowing the utility to pass on grid related information which then triggers facility defined and programmed strategies if convenient to the facility. From 2003 through 2006 Lawrence Berkeley National Laboratory (LBNL) and the Demand Response Research Center (DRRC) developed and tested a series of demand response automation communications technologies known as Automated Demand Response (Auto-DR). In 2007, LBNL worked with three investor-owned utilities to commercialize and implement Auto-DR programs in their territories. This paper summarizes the history of technology development for Auto-DR, and describes the DR technologies and control strategies utilized at many of the facilities. It outlines early experience in commercializing Auto-DR systems within PG&E DR programs, including the steps to configure the automation technology. The paper also describes the DR sheds derived using three different baseline methodologies. Emphasis is given to the lessons learned from installation and commissioning of Auto-DR systems, with a detailed description of the technical coordination roles and responsibilities, and costs.

Global Energy Partners; Pacific Gas and Electric Company; Kiliccote, Sila; Kiliccote, Sila; Piette, Mary Ann; Wikler, Greg; Prijyanonda, Joe; Chiu, Albert

2008-04-21T23:59:59.000Z

39

Automated fuel pin loading system  

DOE Patents [OSTI]

An automated loading system for nuclear reactor fuel elements utilizes a gravity feed conveyor which permits individual fuel pins to roll along a constrained path perpendicular to their respective lengths. The individual lengths of fuel cladding are directed onto movable transports, where they are aligned coaxially with the axes of associated handling equipment at appropriate production stations. Each fuel pin can be reciprocated axially and/or rotated about its axis as required during handling steps. The fuel pins are inserted as a batch prior to welding of end caps by one of two disclosed welding systems.

Christiansen, David W. (Kennewick, WA); Brown, William F. (West Richland, WA); Steffen, Jim M. (Richland, WA)

1985-01-01T23:59:59.000Z

40

Atlas Sodium Automated Batch Synthesis System  

E-Print Network [OSTI]

Atlas Sodium Automated Batch Synthesis System (Syrris) June 2013 #12;Introduction to the system · The Atlas Sodium system consists of an Atlas base equipped with a 400ºC hotplate, a stacking dry bath systemL) for automated addition and/or removal of solution. · The system is computer controlled by the Atlas software

Subramanian, Venkat

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building  

E-Print Network [OSTI]

15 4.1. LightingEvaluation of the Dimmable Lighting, Automated Shading, andcomparison EUI, kBtu/Gsf Lighting Heating Cooling Pumps/C

2013-01-01T23:59:59.000Z

42

Systems building in architecture  

E-Print Network [OSTI]

This work is an inquiry into the interventions of the systems design in the whole building process. At the beginning, three approaches which represent different points of view of interventions in production and use are ...

Tzannetakis, Charilaos Panayotis

1983-01-01T23:59:59.000Z

43

Field Demonstration of Automated Demand Response for Both Winter and Summer Events in Large Buildings in the Pacific Northwest  

SciTech Connect (OSTI)

There are growing strains on the electric grid as cooling peaks grow and equipment ages. Increased penetration of renewables on the grid is also straining electricity supply systems and the need for flexible demand is growing. This paper summarizes results of a series of field test of automated demand response systems in large buildings in the Pacific Northwest. The objective of the research was two fold. One objective was to evaluate the use demand response automation technologies. A second objective was to evaluate control strategies that could change the electric load shape in both winter and summer conditions. Winter conditions focused on cold winter mornings, a time when the electric grid is often stressed. The summer test evaluated DR strategies in the afternoon. We found that we could automate both winter and summer control strategies with the open automated demand response communication standard. The buildings were able to provide significant demand response in both winter and summer events.

Piette, Mary Ann; Kiliccote, Sila; Dudley, Junqiao H.

2011-11-11T23:59:59.000Z

44

Automated Fresnel lens tester system  

SciTech Connect (OSTI)

An automated data collection system controlled by a desktop computer has been developed for testing Fresnel concentrators (lenses) intended for solar energy applications. The system maps the two-dimensional irradiance pattern (image) formed in a plane parallel to the lens, whereas the lens and detector assembly track the sun. A point detector silicon diode (0.5-mm-dia active area) measures the irradiance at each point of an operator-defined rectilinear grid of data positions. Comparison with a second detector measuring solar insolation levels results in solar concentration ratios over the image plane. Summation of image plane energies allows calculation of lens efficiencies for various solar cell sizes. Various graphical plots of concentration ratio data help to visualize energy distribution patterns.

Phipps, G.S.

1981-07-01T23:59:59.000Z

45

Preface: Cognitive Engineering in Automated Systems Design  

E-Print Network [OSTI]

Preface: Cognitive Engineering in Automated Systems Design This special issue was motivated by an apparent paucity of research on applications of cognitive engineering principles in the design of complex systems including mainte- nance, manufacturing, and transportation systems. Cognitive engineering

Kaber, David B.

46

Automated Information System (AIS) Alarm System  

SciTech Connect (OSTI)

The Automated Information Alarm System is a joint effort between Los Alamos National Laboratory, Lawrence Livermore National Laboratory, and Sandia National Laboratory to demonstrate and implement, on a small-to-medium sized local area network, an automated system that detects and automatically responds to attacks that use readily available tools and methodologies. The Alarm System will sense or detect, assess, and respond to suspicious activities that may be detrimental to information on the network or to continued operation of the network. The responses will allow stopping, isolating, or ejecting the suspicious activities. The number of sensors, the sensitivity of the sensors, the assessment criteria, and the desired responses may be set by the using organization to meet their local security policies.

Hunteman, W.

1997-05-01T23:59:59.000Z

47

V-132: IBM Tivoli System Automation Application Manager Multiple...  

Broader source: Energy.gov (indexed) [DOE]

IBM has acknowledged multiple vulnerabilities in IBM Tivoli System Automation Application Manager PLATFORM: The vulnerabilities are reported in IBM Tivoli System Automation...

48

V-205: IBM Tivoli System Automation for Multiplatforms Java Multiple...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

5: IBM Tivoli System Automation for Multiplatforms Java Multiple Vulnerabilities V-205: IBM Tivoli System Automation for Multiplatforms Java Multiple Vulnerabilities July 29, 2013...

49

Predictive building automation Research results from a field trial Special event in Allschwil, Thursday, September 20, 2012  

E-Print Network [OSTI]

Predictive building automation ­ Research results from a field trial Special event in Allschwil-efficient control while maintaining a high level of comfort for the building users. Predictive building automation of computer simulations. The project partners focused on the so-called integrated room automation, which deals

Fischlin, Andreas

50

Building diagnosable distributed systems  

E-Print Network [OSTI]

Building diagnosable distributed systems Petros Maniatis Intel Research Berkeley ICSI ­ Security] Project response@R (R, K, SI) lookup response Specification #12;2/8/2006 Petros Maniatis9 Strawman Design Join lookup.NI == node.NI Join lookup.NI == succ.NI Select K in (N, S] Project response@R (R, K, SI

Maniatis, Petros

51

Automated Demand Response Strategies and Commissioning Commercial Building Controls  

E-Print Network [OSTI]

4 9 . Piette et at Automated Demand Response Strategies andDynamic Controls for Demand Response in New and ExistingFully Automated Demand Response Tests in Large Facilities"

Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

2006-01-01T23:59:59.000Z

52

Making Automated Building Code Checking A Reality1 Charles S. Han, John Kunz, Kincho H. Law  

E-Print Network [OSTI]

in the September/October 1997 issue of Facility Management Journal 1 #12;2. A Building Model Standard In orderMaking Automated Building Code Checking A Reality1 Charles S. Han, John Kunz, Kincho H. Law Center set of building codes. The complexity and changing nature of codes leads to delays in both the design

Stanford University

53

Automated Demand Response Strategies and Commissioning Commercial Building Controls  

E-Print Network [OSTI]

for Demand Response in New and Existing Commercial BuildingsDemand Response Strategies and National Conference on BuildingDemand Response Strategies and Commissioning Commercial Building

Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

2006-01-01T23:59:59.000Z

54

Monitoring Building Systems for Schedule Compliance  

SciTech Connect (OSTI)

As Pacific Northwest National Laboratory (PNNL) initiated a Core Business Hours program, it became a challenge to ensure that the hundreds of systems campus wide were operating within their programmed schedules. Therefore, a collaborative exchange between PNNL operations and PNNL researchers developing the Decision Support for Operations and Maintenance (DSOM) software package was initiated to create a tool to solve this problem. This new DSOM tool verifies systems are operating within scheduled operation times by polling Building Automation and Control Network (BACnet) identifiers of systems’ on/off or command statuses. The tool records the time spent in operation state (ON) and totalizes each system over a rolling 7-day period, highlighting systems that are running over the scheduled hours. This snapshot view allows building management to look quickly at the entire campus to ensure that systems are not operating beyond their scheduled hours.

Jensen, Andrew M.; Belew, Shan T.

2013-02-19T23:59:59.000Z

55

Building America System Research  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev next > Sun Mon TueBuilding America System

56

Automated Transportation Management System (ATMS)  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd: Scope ChangeL-01-06 AuditAugust 5,Re evised June 2010 Autom The

57

Automated Demand Response Technology Demonstration Project for Small and Medium Commercial Buildings  

SciTech Connect (OSTI)

Small and medium commercial customers in California make up about 20-25% of electric peak load in California. With the roll out of smart meters to this customer group, which enable granular measurement of electricity consumption, the investor-owned utilities will offer dynamic prices as default tariffs by the end of 2011. Pacific Gas and Electric Company, which successfully deployed Automated Demand Response (AutoDR) Programs to its large commercial and industrial customers, started investigating the same infrastructures application to the small and medium commercial customers. This project aims to identify available technologies suitable for automating demand response for small-medium commercial buildings; to validate the extent to which that technology does what it claims to be able to do; and determine the extent to which customers find the technology useful for DR purpose. Ten sites, enabled by eight vendors, participated in at least four test AutoDR events per site in the summer of 2010. The results showed that while existing technology can reliably receive OpenADR signals and translate them into pre-programmed response strategies, it is likely that better levels of load sheds could be obtained than what is reported here if better understanding of the building systems were developed and the DR response strategies had been carefully designed and optimized for each site.

Page, Janie; Kiliccote, Sila; Dudley, Junqiao Han; Piette, Mary Ann; Chiu, Albert K.; Kellow, Bashar; Koch, Ed; Lipkin, Paul

2011-07-01T23:59:59.000Z

58

Sustainable Building Rating Systems Summary  

SciTech Connect (OSTI)

The purpose of this document is to offer information that could be used to compare and contrast sustainable building rating systems.

Fowler, Kimberly M.; Rauch, Emily M.

2006-07-01T23:59:59.000Z

59

Building Design Advisor: Automated integration of multiple simulation tools K. Papamichael, J. LaPorta, H. Chauvet  

E-Print Network [OSTI]

LBNL-40591 Preprint Building Design Advisor: Automated integration of multiple simulation tools K Design Advisor (BDA) is a software environment that supports the integrated use of multiple analysis

60

Automated Fuel Dispensing System Form Instructions  

E-Print Network [OSTI]

Automated Fuel Dispensing System Form Instructions If additional forms are necessary to provide(s) are hired and will be obtaining fuel, an Add Driver Form MUST be submitted for entry into the web database and/or diesel fuel to operate. Note: When a new vehicle, golf cart (gasoline), etc., is placed

Fernandez, Eduardo

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

System information database: an automated maintenance aid  

SciTech Connect (OSTI)

This paper is a case study of how one DP organization applied student labor and a relational DBMS in a prototyping environment to automate much of their applications systems documentation function. The capabilities, fringe benefits and future enhancements of the tool are discussed.

Brice, L.; Connell, J.

1984-01-01T23:59:59.000Z

62

Classified Automated Information System Security Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To establish uniform requirements, policies, responsibilities, and procedures for the development and implementation of a Department of Energy (DOE) Classified Computer Security Program to ensure the security of classified information in automated data processing (ADP) systems. Cancels DOE O 5637.1. Canceled by DOE O 471.2.

1994-07-15T23:59:59.000Z

63

Salsbury and Diamond: Automated Testing of HVAC Systems for Commissioning -1 -Automated Testing of HVAC Systems for Commissioning  

E-Print Network [OSTI]

and Diamond: Automated Testing of HVAC Systems for Commissioning - 1 - Automated Testing of HVAC Systems This paper describes an approach to the automation of the commissioning of HVAC systems. The approach of many HVAC systems is limited more by poor installation, commissioning, and maintenance than by poor

64

Interdisciplinary Research Experiences in Mechatronics, Robotics, and Automated System Design  

E-Print Network [OSTI]

Interdisciplinary Research Experiences in Mechatronics, Robotics, and Automated System Design Texas for undergraduate students to learn about mechatronics, robotics, and automated system design. Program objectives in research and interest in a career in mechatronics, robotics or automated system design, as evidenced

65

Webinar: Make Your Building Sing!: Building-Retuning to Reduce...  

Broader source: Energy.gov (indexed) [DOE]

(PNNL) developed a curricula focused on retuning both large (with a building automation system, or BAS) and small (without a BAS) commercial buildings. Hear from Better...

66

Energy Department Issues Green Building Certification System...  

Broader source: Energy.gov (indexed) [DOE]

Issues Green Building Certification System Final Rule to Support Increased Energy Measurement and Efficient Building Design Energy Department Issues Green Building Certification...

67

Integrated Building Management System (IBMS)  

SciTech Connect (OSTI)

This project provides a combination of software and services that more easily and cost-effectively help to achieve optimized building performance and energy efficiency. Featuring an open-platform, cloud- hosted application suite and an intuitive user experience, this solution simplifies a traditionally very complex process by collecting data from disparate building systems and creating a single, integrated view of building and system performance. The Fault Detection and Diagnostics algorithms developed within the IBMS have been designed and tested as an integrated component of the control algorithms running the equipment being monitored. The algorithms identify the normal control behaviors of the equipment without interfering with the equipment control sequences. The algorithms also work without interfering with any cooperative control sequences operating between different pieces of equipment or building systems. In this manner the FDD algorithms create an integrated building management system.

Anita Lewis

2012-07-01T23:59:59.000Z

68

Vehicle Following Control Design for Automated Highway Systems  

E-Print Network [OSTI]

Vehicle Following Control Design for Automated Highway Systems H. Raza and P. Ioannou A, utomatic vehicle following isan important feature of a fully rpartially automated highwaysystem (AHS is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal

Ioannou, Petros

69

Modular and Generic Control Software System for Scalable Automation  

E-Print Network [OSTI]

Modular and Generic Control Software System for Scalable Automation Christian Brecher, Martin.freundt@ipt.fraunhofer.de Abstract. The development of automated production systems is subdivided in two mayor tasks. One production with a high rate of changes, this is why fully automated solutions don't pay off and manual

Paris-Sud XI, Université de

70

Findings from Seven Years of Field Performance Data for Automated Demand Response in Commercial Buildings  

SciTech Connect (OSTI)

California is a leader in automating demand response (DR) to promote low-cost, consistent, and predictable electric grid management tools. Over 250 commercial and industrial facilities in California participate in fully-automated programs providing over 60 MW of peak DR savings. This paper presents a summary of Open Automated DR (OpenADR) implementation by each of the investor-owned utilities in California. It provides a summary of participation, DR strategies and incentives. Commercial buildings can reduce peak demand from 5 to 15percent with an average of 13percent. Industrial facilities shed much higher loads. For buildings with multi-year savings we evaluate their load variability and shed variability. We provide a summary of control strategies deployed, along with costs to install automation. We report on how the electric DR control strategies perform over many years of events. We benchmark the peak demand of this sample of buildings against their past baselines to understand the differences in building performance over the years. This is done with peak demand intensities and load factors. The paper also describes the importance of these data in helping to understand possible techniques to reach net zero energy using peak day dynamic control capabilities in commercial buildings. We present an example in which the electric load shape changed as a result of a lighting retrofit.

Kiliccote, Sila; Piette, Mary Ann; Mathieu, Johanna; Parrish, Kristen

2010-05-14T23:59:59.000Z

71

Exploiting Home Automation Protocols for Load Monitoring in Smart Buildings  

E-Print Network [OSTI]

to reduce consumption is also impor- tant. Smart buildings use demand-side energy management to self consumption with renewable generation [17]. Demand- side management requires buildings to 1) continuously mon@cs.williams.edu Abstract Monitoring and controlling electrical loads is crucial for demand-side energy management in smart

Massachusetts at Amherst, University of

72

Development of Building Automation and Control Systems  

E-Print Network [OSTI]

www. automatedlogic.com. [3] Modelica. [Online]. Available:as Simulink [4] and Modelica [3]Vand the available back-enduser input (e.g. , Simulink and Modelica), and to the output

Yang, Yang; Zhu, Qi; Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

73

Installation and Commissioning Automated Demand Response Systems  

E-Print Network [OSTI]

their partnership in demand response automation research andand Techniques for Demand Response. LBNL Report 59975. Mayof Fully Automated Demand Response in Large Facilities.

Kiliccote, Sila; Global Energy Partners; Pacific Gas and Electric Company

2008-01-01T23:59:59.000Z

74

Introducing the Web-of-Things in Building Automation: A Gateway for KNX installations  

E-Print Network [OSTI]

{gerome.bovet, jean.hennebert}@hefr.ch Keywords: Smart Buildings, Web-of-Things, RESTful, KNX, Building systems. Buildings have become "smart" and are now real information sys- tems using dedicated building. Figure 1: Network heterogeneity in smart buildings Web services are nowadays widespread in hetero

Paris-Sud XI, Université de

75

Automated High-Pressure Titration System with In Situ Infrared...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

High-Pressure Titration System with In Situ Infrared Spectroscopic Detection. Automated High-Pressure Titration System with In Situ Infrared Spectroscopic Detection. Abstract: A...

76

Enhancing Building Operations Through Automated Diagnostics: Field Test Results  

E-Print Network [OSTI]

According to the Annual Energy Outlook 2003 (EIA 2003), in 2001, 17.4 quadrillion Btu (1 quad = 1015 Btu) of primary energy was consumed by commercial buildings in the United States at a cost of about 127 billion dollars (in 2001 dollars). Many... maintenance is clearly insufficient to address this issue. Manually commissioning buildings is valuable in terms of both finding problems and developing the techniques for doing so, but it is expensive. With only 1 to 2% of total construction costs...

Katipamula, S.; Brambley, M. R.; Bauman, N.; Pratt, R. G.

2003-01-01T23:59:59.000Z

77

A Loop Material Flow System Design for Automated Guided Vehicles  

E-Print Network [OSTI]

A Loop Material Flow System Design for Automated Guided Vehicles Ardavan Asef-Vaziri 1 Maged load automated guided vehicles. The model simultaneously determines both the design are attributed to material handling (Tompkins et al., 1996). Automated guided vehicles (AGVs) are among

Dessouky, Maged

78

System Performances under Automation Degradation E. Hollnagel3  

E-Print Network [OSTI]

System Performances under Automation Degradation (SPAD) E. Hollnagel3 , C. Martinie1 , P. Palanque1 of the project objectives augmented by some early findings. Abstract - Increased automation is one of the main changes foreseen by SESAR in ATM. This will pose new challenges including possible automation degradation

Boyer, Edmond

79

National System Templates: Building Sustainable National Inventory...  

Open Energy Info (EERE)

Templates: Building Sustainable National Inventory Management Systems Jump to: navigation, search Tool Summary LAUNCH TOOL Name: National System Templates: Building Sustainable...

80

Basement Insulation Systems - Building America Top Innovation...  

Energy Savers [EERE]

Basement Insulation Systems - Building America Top Innovation Basement Insulation Systems - Building America Top Innovation This photo shows a framed basement wall with insulation...

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Building America Webinar: Ductless Hydronic Distribution Systems...  

Energy Savers [EERE]

Building America Webinar: Ductless Hydronic Distribution Systems Building America Webinar: Ductless Hydronic Distribution Systems This webinar was presented by research team...

82

Variability in Automated Responses of Commercial Buildings and Industrial Facilities to Dynamic Electricity Prices  

SciTech Connect (OSTI)

Changes in the electricity consumption of commercial buildings and industrial facilities (C&I facilities) during Demand Response (DR) events are usually estimated using counterfactual baseline models. Model error makes it difficult to precisely quantify these changes in consumption and understand if C&I facilities exhibit event-to-event variability in their response to DR signals. This paper seeks to understand baseline model error and DR variability in C&I facilities facing dynamic electricity prices. Using a regression-based baseline model, we present a method to compute the error associated with estimates of several DR parameters. We also develop a metric to determine how much observed DR variability results from baseline model error rather than real variability in response. We analyze 38 C&I facilities participating in an automated DR program and find that DR parameter errors are large. Though some facilities exhibit real DR variability, most observed variability results from baseline model error. Therefore, facilities with variable DR parameters may actually respond consistently from event to event. Consequently, in DR programs in which repeatability is valued, individual buildings may be performing better than previously thought. In some cases, however, aggregations of C&I facilities exhibit real DR variability, which could create challenges for power system operation.

Mathieu, Johanna L.; Callaway, Duncan S.; Kiliccote, Sila

2011-08-16T23:59:59.000Z

83

Variability in Automated Responses of Commercial Buildings and Industrial  

E-Print Network [OSTI]

for buildings to change their electricity consumption patterns through both "shifts" in energy use and load to Dynamic Electricity Prices Johanna L. Mathieu, Duncan S. Callaway, Sila Kiliccote Environmental Energy was prepared as an account of work sponsored by the United States Government. While this document is believed

84

Intelligent Building Automation: A Demand Response Management Perspective  

E-Print Network [OSTI]

the energy consumption in response to energy price fluctuations, demand charges, or a direct request to reduce demand when the power grid reaches critical levels. However, in order for a demand response regime to be effective the building will need to have a...

Qazi, T.

2010-01-01T23:59:59.000Z

85

ATLAS Nightly Build System Upgrade  

E-Print Network [OSTI]

The ATLAS Nightly Build System is a facility for automatic production of software releases. Being the major component of ATLAS software infrastructure, it supports more than 50 multi-platform branches of nightly releases and provides ample opportunities for testing new packages, for verifying patches to existing software, and for migrating to new platforms and compilers. The Nightly System testing framework runs several hundred integration tests of different granularity and purpose. The nightly releases are distributed and validated, and some are transformed into stable releases used for data processing worldwide. The first LHC long shutdown (2013-2015) activities will elicit increased load on the Nightly System as additional releases and builds are needed to exploit new programming techniques, languages, and profiling tools. This paper describes the plan of the ATLAS Nightly Build System Long Shutdown upgrade. It brings modern database and web technologies into the Nightly System, improves monitoring of nigh...

Dimitrov, G; The ATLAS collaboration; Simmons, B; Undrus, A

2013-01-01T23:59:59.000Z

86

An automated vacuum gauge calibration system  

SciTech Connect (OSTI)

An automated system for calibrating vacuum gauges over the pressure range of 10{sup {minus}6} to 0.1 Pa was designed and constructed at the National Institute of Standards and Technology (NIST) for the Department of Energy (DOE) Primary Standards Laboratory at Sandia National Laboratories (SNL). Calculable pressures are generated by passing a known flow of gas through an orifice of known conductance. The orifice conductance is derived from dimensional measurements and accurate flows are generated using metal capillary leaks. The expanded uncertainty (k = 2) in the generated pressure is estimated to be between 1% and 4% over the calibration range. The design, calibration results. and component uncertainties will be discussed.

Abbott, P.J. [NIST, GAithersburg, MD (United States); Benner, M.S. [Sandia National Labs., Albuquerque, NM (United States)

1998-04-01T23:59:59.000Z

87

Automated radioanalytical system for the determination of Sr...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

that can be detected by photomultiplier tubes with good sensitivity, without the use of scintillation cocktails. A laboratory-based automated fluid handling system coupled to a...

88

Reference Model for Control and Automation Systems in Electrical...  

Broader source: Energy.gov (indexed) [DOE]

Modern infrastructure automation systems are threatened by cyber attack. Their higher visibility in recent years and the increasing use of modern information technology (IT)...

89

automated radar terminal system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

90

automated distribution system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

91

automated design system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

92

automated systems based: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

93

automated tracking system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

94

automation system nas: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

95

automated highway system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

96

automated monitoring system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

97

automated microbiology system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

98

automated cots system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

99

automated ventricular systems: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

100

automated control systems: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

automated culture systems: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

102

acquisition automated system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

103

automated highway systems: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

104

automated control system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

105

automated diagnostic system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

106

automated classification system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

107

Reference Model for Control and Automation Systems in Electrical...  

Broader source: Energy.gov (indexed) [DOE]

Reference Model for Control and Automation Systems in Electrical Power Version 1.2 October 12, 2005 Prepared by: Sandia National Laboratories' Center for SCADA Security Jason...

108

automated test system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

design: Choosing inputs Mousavi, Mohammad 2 Automated System Testing of Dynamic Web Applications CiteSeer Summary: Abstract. Web applications pervade all aspects of human...

109

System/Building Tech Integration | Clean Energy | ORNL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

SystemBuilding Integration SHARE System Building Technologies Integration The buildings industry encompasses numerous designers, builders, construction materials and components...

110

INTEGRATED ENERGY SYSTEMS: PRODUCTIVITY & BUILDING SCIENCE  

E-Print Network [OSTI]

Integrated Design of Commercial Building Ceiling Systems Integrated Design of Residential Ducting & Air FlowINTEGRATED ENERGY SYSTEMS: PRODUCTIVITY & BUILDING SCIENCE Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems

111

International Symposium on Daylighting Buildings (IEA SHC TASK 31) Integrating Automated Shading and Smart Glazings with Daylight  

E-Print Network [OSTI]

International Symposium on Daylighting Buildings (IEA SHC TASK 31) Integrating Automated Shading and Smart Glazings with Daylight Controls Stephen Selkowitz Eleanor Lee Lawrence Berkeley National Laboratory Keywords: daylighting, controls, smart glazing, shading, field testing, IEA31 1. INTRODUCTION Most

112

Open Automated Demand Response for Small Commerical Buildings  

E-Print Network [OSTI]

HVAC Control System Advanced Telemetry No DDC Zone Control Data Trending DDC Zone Control Data Trending Detail EMCS Trends

Dudley, June Han

2009-01-01T23:59:59.000Z

113

Integrated Building Energy Systems Design Considering Storage Technologies  

E-Print Network [OSTI]

L ABORATORY Integrated Building Energy Systems Design7301 Integrated building energy systems design considering

Stadler, Michael

2009-01-01T23:59:59.000Z

114

Retrospective Testing of an Automated Building Commissioning Analysis Tool (ABCAT)  

E-Print Network [OSTI]

Laboratory Texas A&M University System College Station, Texas 777843-3581 January 2009 2 Disclaimer This report was prepared by the Energy Systems Laboratory (ESL) for the Lawrence Berkeley National Laboratory (LBNL). Neither the ESL... or LBNL or any of their employees, makes any warranty, express or implies or assumes any legal liability or responsibility for the accuracy, completeness or usefulness of any information, apparatus, product, or process disclosed, or represents that its...

Claridge, D. E.; Lin, G.

115

Automated interferometric alignment system for paraboloidal mirrors  

DOE Patents [OSTI]

A method is described for a systematic method of interpreting interference fringes obtained by using a corner cube retroreflector as an alignment aid when aigning a paraboloid to a spherical wavefront. This is applicable to any general case where such alignment is required, but is specifically applicable in the case of aligning an autocollimating test using a diverging beam wavefront. In addition, the method provides information which can be systematically interpreted such that independent information about pitch, yaw and focus errors can be obtained. Thus, the system lends itself readily to automation. Finally, although the method is developed specifically for paraboloids, it can be seen to be applicable to a variety of other aspheric optics when applied in combination with a wavefront corrector that produces a wavefront which, when reflected from the correctly aligned aspheric surface will produce a collimated wavefront like that obtained from the paraboloid when it is correctly aligned to a spherical wavefront.

Maxey, L. Curtis (Powell, TN)

1993-01-01T23:59:59.000Z

116

Automated interferometric alignment system for paraboloidal mirrors  

DOE Patents [OSTI]

A method is described for a systematic method of interpreting interference fringes obtained by using a corner cube retroreflector as an alignment aid when aligning a paraboloid to a spherical wavefront. This is applicable to any general case where such alignment is required, but is specifically applicable in the case of aligning an autocollimating test using a diverging beam wavefront. In addition, the method provides information which can be systematically interpreted such that independent information about pitch, yaw and focus errors can be obtained. Thus, the system lends itself readily to automation. Finally, although the method is developed specifically for paraboloids, it can be seen to be applicable to a variety of other aspheric optics when applied in combination with a wavefront corrector that produces a wavefront which, when reflected from the correctly aligned aspheric surface will produce a collimated wavefront like that obtained from the paraboloid when it is correctly aligned to a spherical wavefront. 14 figures.

Maxey, L.C.

1993-09-28T23:59:59.000Z

117

Intelligent Building Energy Information and Control Systems for Low-Energy Operations and Optimal Demand Response  

E-Print Network [OSTI]

account  demand  response  signals,  building?integrated of Automated Demand Response in Commercial Buildings.  and Demand Response in Commercial  Buildings. , LBNL 

Piette, Mary Ann

2014-01-01T23:59:59.000Z

118

Safety Analysis Of Automated Highway Systems  

E-Print Network [OSTI]

Lee. Towards an automated fmea assis- tant. In Applicationsmodes and effects analysis (FMEA) is employed to determineof multiple failures. ) FMEA was developed Potential Part

Leveson, Nancy G.

1997-01-01T23:59:59.000Z

119

E-Print Network 3.0 - automated watering systems Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

automated sample extraction injection systems have been installed... to the Lab's Quattro Micro triple quadrupole mass spectrometer. The Symbiosys Enviro is an automated system......

120

Building America Expert Meeting: Minutes from Automated Home Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EEREDepartmentFebruary 4,Brent NelsonEvaluationHomesFieldManagement System

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Integrating Renewable Energy Systems in Buildings (Presentation)  

SciTech Connect (OSTI)

This presentation on integrating renewable energy systems into building was presented at the August, 2011 ASHRAE Region IX CRC meetings.

Hayter, S. J.

2011-08-01T23:59:59.000Z

122

Building International Emergency Management Systems | National...  

National Nuclear Security Administration (NNSA)

Building International Emergency Management Systems | National Nuclear Security Administration Facebook Twitter Youtube Flickr RSS People Mission Managing the Stockpile Preventing...

123

Remote-Controlled Home Automation Systems with Different Network Technologies  

E-Print Network [OSTI]

in order to close a circuit of a battery and light bulb. Later, companies developed automated systems word formed from domus (Latin, meaning house) and robotics" (click on this link for more information

Grout, Vic

124

automated paging system: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Next Page Last Page Topic Index 1 Automated Web Page Synthesis in Adaptive Web Systems Computer Technologies and Information Sciences...

125

E-Print Network 3.0 - automation simulation system Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: Information and Reservation System" "Automated Phone Book Management System" "Simulation of Searching Family... HMI" "Security System Simulator" "Performance Comparison...

126

Knowledge-Based Automation of a Design Method for Concurrent Systems  

E-Print Network [OSTI]

Knowledge-Based Automation of a Design Method for Concurrent Systems Kevin L. Mills, Senior Member to automate a software design method for concurrent systems. The approach uses multiple paradigms to represent-system shell, compose CODA, an automated designer's assistant. Other forms of automated reasoning

127

Automated Test Coverage Measurement for Reactor Protection System Software  

E-Print Network [OSTI]

Automated Test Coverage Measurement for Reactor Protection System Software Implemented in Function- ing a case study using test cases prepared by domain experts for reactor protection system software) are widely used to implement safety- critical systems such as nuclear reactor protection systems, testing

128

Energy Management Systems Package for Small Commercial Buildings...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Energy Management Systems Package for Small Commercial Buildings Energy Management Systems Package for Small Commercial Buildings Commercial Buildings Integration Project for the...

129

Modeling of Residential Buildings and Heating Systems  

E-Print Network [OSTI]

-zone building model is used in each case. A model of the heating system is also used for the multi-storey building. Both co-heating and tracer gas measurements are used in order to adjust the parameters of each building model. A complete monitoring...

Masy, G.; Lebrun, J.

2004-01-01T23:59:59.000Z

130

FEMP Presents Its Newest On-Demand eTraining Course on Building...  

Energy Savers [EERE]

On-Demand eTraining Course on Building Automation Systems FEMP Presents Its Newest On-Demand eTraining Course on Building Automation Systems November 19, 2013 - 12:00am Addthis...

131

Advanced Commercial Buildings Research; Electricity, Resources, & Building Systems Integration (Fact Sheet)  

SciTech Connect (OSTI)

Factsheet describing the Advanced Commercial Buildings Research group within NREL's Electricity, Resources, and Buildings Systems Integration Center.

Not Available

2009-09-01T23:59:59.000Z

132

Automated Web Page Synthesis in Adaptive Web Systems  

E-Print Network [OSTI]

Automated Web Page Synthesis in Adaptive Web Systems Hossein Sadat and Ali Ghorbani Intelligent, Canada {t15h7,ghorbani}@unb.ca Abstract. An adaptive Web system adapts the Web pages to its users, based of the system. In this paper, we formalize dynamic generation of Web pages and refer to it as Web page synthesis

Ghorbani, Ali

133

Findings from Seven Years of Field Performance Data for Automated Demand Response in Commercial Buildings  

E-Print Network [OSTI]

Open Automated Demand Response Demonstration Project” LBNL-2009a). “Open Automated Demand Response Communications inand Actions for Industrial Demand Response in California. ”

Kiliccote, Sila

2010-01-01T23:59:59.000Z

134

Automated rapid thermal imaging systems technology  

E-Print Network [OSTI]

A major source of energy savings occurs on the thermal envelop of buildings, which amounts to approximately 10% of annual energy usage in the United States. To pursue these savings, energy auditors use closed loop energy ...

Phan, Long N., 1976-

2012-01-01T23:59:59.000Z

135

"We retrofitted mechanical systems in 8 buildings!"  

E-Print Network [OSTI]

"We retrofitted mechanical systems in 8 buildings!" LOW INTEREST RATE LOANS AVAILABLE NOW! County of Contra Costa California Energy Commission Apply Today! See Case Study on Back of Flyer "Our low interest and cooling systems in eight buildings. The energy efficient measures include replacing pneumatic controls

136

Automated Surface Observing System: Standby Power Options  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3--Logistical5/08 Attendance List1-02Evaluation Report(AO) AuthorizingAutomated

137

MEMS CHIP CO2 SENSOR FOR BUILDING SYSTEMS INTEGRATION  

SciTech Connect (OSTI)

The objective of this research was to develop an affordable, reliable sensor to enable demand controlled ventilation (DCV). A significant portion of total energy consumption in the United States is used for heating or air conditioning (HVAC) buildings. To assure occupant safety and fresh air levels in large buildings, and especially those with sealed windows, HVAC systems are frequently run in excess of true requirements as automated systems cannot now tell the occupancy level of interior spaces. If such a sensor (e.g. thermostat sized device) were available, it would reduce energy use between 10 and 20% in such buildings. A quantitative measure of ''fresh air'' is the concentration of carbon dioxide (CO{sub 2}) present. An inert gas, CO{sub 2} is not easily detected by chemical sensors and is usually measured by infrared spectroscopy. Ion Optics research developed a complete infrared sensor package on a single MEMS chip. It contains the infrared (IR) source, IR detector and IR filter. The device resulting from this DOE sponsored research has sufficient sensitivity, lifetime, and drift rate to meet the specifications of commercial instrument manufacturers who are now testing the device for use in their building systems.

Anton Carl Greenwald

2005-09-14T23:59:59.000Z

138

Automation of Capacity Bidding with an Aggregator Using Open Automated Demand Response  

E-Print Network [OSTI]

Protocol for Building Automation and Control  Networks.  Protocol for Building Automation and Control  Networks, Demand Response Automation Server  Demand Response Research 

Kiliccote, Sila

2011-01-01T23:59:59.000Z

139

Control System Commissioning for Enhanced Building Operations  

E-Print Network [OSTI]

This paper highlights the import role control systems play in the operation of modern buildings and describes ways to improve the final stage of commissioning. We also describe practical issues associated with modern IT-oriented control systems...

Salsbury, T. I.; Singhal, A.

2003-01-01T23:59:59.000Z

140

Co-simulation of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

Developing an Integrated Building Design Tool by Couplingdesign energy ecient building systems in this complex setting, integrated

Trcka, Marija

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Building operating systems services: An architecture for programmable buildings.  

E-Print Network [OSTI]

7.3.2 Building Performance Analysis . . . . . . 7.4 RelatedWork 2.1 Building Physical Design . . . . . . . . . .3.2.6 Building Applications . . . . . . . . . . .

Dawson-Haggerty, Stephen

2014-01-01T23:59:59.000Z

142

An Automation System for Optimizing a Supply Chain Network Design under the Influence of Demand Uncertainty  

E-Print Network [OSTI]

Automation . . . . . . . . . . . . . . . . . . . . . . iii 3Automation . . . . . . . . . . . . . . . . . . . . . . 5Dashboard/Cockpit Automation . . . . . . . . . . . . .

Polany, Rany

2012-01-01T23:59:59.000Z

143

Automated transportation management system (ATMS) software project management plan (SPMP)  

SciTech Connect (OSTI)

The Automated Transportation Management System (ATMS) Software Project Management plan (SPMP) is the lead planning document governing the life cycle of the ATMS and its integration into the Transportation Information Network (TIN). This SPMP defines the project tasks, deliverables, and high level schedules involved in developing the client/server ATMS software.

Weidert, R.S., Westinghouse Hanford

1996-05-20T23:59:59.000Z

144

Development of an Automated Tracking System of Tagged Wild Animals  

E-Print Network [OSTI]

Development of an Automated Tracking System of Tagged Wild Animals Mariya Ishutkina1 Timothy Chan2 and there are about a hundred of them living in the wild. For tracking purposes, each animal is outfitted remaining animals and established a captive-breeding program to restore red wolves in the wild. As pointed

145

Automated Energy Distribution and Reliability System (AEDR): Final Report  

SciTech Connect (OSTI)

This report describes Northern Indiana Public Service Co. project efforts to develop an automated energy distribution and reliability system. The purpose of this project was to implement a database-driven GIS solution that would manage all of the company's gas, electric, and landbase objects.

Buche, D. L.

2008-07-01T23:59:59.000Z

146

Geothermal System Overview ASHRAE Headquarters Building  

E-Print Network [OSTI]

Geothermal System Overview ASHRAE Headquarters Building Dennis Meyer Director of Commercial Sales center #12;Geothermal Loop · Vertical closed-loop ­ 12 bores at 400 feet deep with 1.25" HDPE ­ Boreholes enhanced grout · Standard 2-pipe building loop with VFD pump #12;#12;#12;#12;ClimateMaster Geothermal

Oak Ridge National Laboratory

147

A Automated Tool for Supporting FMEAs of Digital Systems  

SciTech Connect (OSTI)

Although designs of digital systems can be very different from each other, they typically use many of the same types of generic digital components. Determining the impacts of the failure modes of these generic components on a digital system can be used to support development of a reliability model of the system. A novel approach was proposed for such a purpose by decomposing the system into a level of the generic digital components and propagating failure modes to the system level, which generally is time-consuming and difficult to implement. To overcome the associated issues of implementing the proposed FMEA approach, an automated tool for a digital feedwater control system (DFWCS) has been developed in this study. The automated FMEA tool is in nature a simulation platform developed by using or recreating the original source code of the different module software interfaced by input and output variables that represent physical signals exchanged between modules, the system, and the controlled process. For any given failure mode, its impacts on associated signals are determined first and the variables that correspond to these signals are modified accordingly by the simulation. Criteria are also developed, as part of the simulation platform, to determine whether the system has lost its automatic control function, which is defined as a system failure in this study. The conceptual development of the automated FMEA support tool can be generalized and applied to support FMEAs for reliability assessment of complex digital systems.

Yue,M.; Chu, T.-L.; Martinez-Guridi, G.; Lehner, J.

2008-09-07T23:59:59.000Z

148

Transforming Commercial Building Operations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

& Publications Retrocommissioning and the Public Sector retrocommissioningpublicsector.doc Small- and Medium-Size Building Automation and Control System Needs: Scoping Study...

149

3D World Building System  

SciTech Connect (OSTI)

This video provides an overview of the Sandia National Laboratories developed 3-D World Model Building capability that provides users with an immersive, texture rich 3-D model of their environment in minutes using a laptop and color and depth camera.

None

2013-10-30T23:59:59.000Z

150

3D World Building System  

ScienceCinema (OSTI)

This video provides an overview of the Sandia National Laboratories developed 3-D World Model Building capability that provides users with an immersive, texture rich 3-D model of their environment in minutes using a laptop and color and depth camera.

None

2014-02-26T23:59:59.000Z

151

Chip breaking system for automated machine tool  

DOE Patents [OSTI]

The invention is a rotary selectively directional valve assembly for use in an automated turret lathe for directing a stream of high pressure liquid machining coolant to the interface of a machine tool and workpiece for breaking up ribbon-shaped chips during the formation thereof so as to inhibit scratching or other marring of the machined surfaces by these ribbon-shaped chips. The valve assembly is provided by a manifold arrangement having a plurality of circumferentially spaced apart ports each coupled to a machine tool. The manifold is rotatable with the turret when the turret is positioned for alignment of a machine tool in a machining relationship with the workpiece. The manifold is connected to a non-rotational header having a single passageway therethrough which conveys the high pressure coolant to only the port in the manifold which is in registry with the tool disposed in a working relationship with the workpiece. To position the machine tools the turret is rotated and one of the tools is placed in a material-removing relationship of the workpiece. The passageway in the header and one of the ports in the manifold arrangement are then automatically aligned to supply the machining coolant to the machine tool workpiece interface for breaking up of the chips as well as cooling the tool and workpiece during the machining operation.

Arehart, Theodore A. (Clinton, TN); Carey, Donald O. (Oak Ridge, TN)

1987-01-01T23:59:59.000Z

152

Web-based energy information systems for large commercial buildings  

SciTech Connect (OSTI)

Energy Information Systems (EIS), which monitor and organize building energy consumption and related trend data over the Internet, have been evolving over the past decade. This technology helps perform key energy management functions such as organizing energy use data, identifying energy consumption anomalies, managing energy costs, and automating demand response strategies. During recent years numerous developers and vendors of EIS have been deploying these products in a highly competitive market. EIS offer various software applications and services for a variety of purposes. Costs for such system vary greatly depending on the system's capabilities and how they are marketed. Some products are marketed directly to end users while others are made available as part of electric utility programs. EIS can be a useful tool in building commissioning and retro-commissioning. This paper reviews more than a dozen EIS. We have developed an analytical framework to characterize the main features of these products, which are developed for a variety of utility programs and end-use markets. The purpose of this research is to evaluate EIS capabilities and limitations, plus examine longer-term opportunities for utilizing such technology to improve building energy efficiency and load management.

Motegi, Naoya; Piette, Mary Ann

2003-03-29T23:59:59.000Z

153

Variability in Automated Responses of Commercial Buildings and Industrial Facilities to Dynamic Electricity Prices  

E-Print Network [OSTI]

building control strategies and techniques for demand response,”demand response and energy ef?ciency in commercial buildings,”building electricity use with application to demand response,”

Mathieu, Johanna L.

2012-01-01T23:59:59.000Z

154

Automated Demand Response Technology Demonstration Project for Small and Medium Commercial Buildings  

E-Print Network [OSTI]

Demand Response for Small Commercial Buildings.   Lawrence small?medium buildings’ roles in demand response  efforts.  demand response for small? medium commercial buildings 

Page, Janie

2012-01-01T23:59:59.000Z

155

Design and Operation of an Open, Interoperable Automated Demand Response Infrastructure for Commercial Buildings  

E-Print Network [OSTI]

and Demand Response in Commercial Building,” Report No.Demand Response Infrastructure for Commercial Buildings MaryDemand Response Infrastructure for Commercial Buildings Mary

Piette, Mary Ann

2010-01-01T23:59:59.000Z

156

Evaluation of Automated Model Calibration Techniques for Residential Building Energy Simulation  

SciTech Connect (OSTI)

This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define 'explicit' input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAE 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.

Robertson, J.; Polly, B.; Collis, J.

2013-09-01T23:59:59.000Z

157

Energy Savings Through Improved Mechanical Systems and Building...  

Office of Environmental Management (EM)

Energy Savings Through Improved Mechanical Systems and Building Envelope Technologies (DE-FOA-0000621) Energy Savings Through Improved Mechanical Systems and Building Envelope...

158

Advanced Framing Systems and Packages - Building America Top...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Advanced Framing Systems and Packages - Building America Top Innovation Advanced Framing Systems and Packages - Building America Top Innovation This photo shows advanced framing...

159

Balancing Hydronic Systems in Multifamily Buildings  

SciTech Connect (OSTI)

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

Ruch, R.; Ludwig, P.; Maurer, T.

2014-07-01T23:59:59.000Z

160

Automated Fault Location In Smart Distribution Systems  

E-Print Network [OSTI]

of utilizing a suitable fault location method. As distribution systems are gradually evolving into smart distribution systems, application of more accurate fault location methods based on gathered data from various Intelligent Electronic Devices (IEDs...

Lotfifard, Saeed

2012-10-19T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Genetic algorithms for delays evaluation in networked automation systems , S. Amari, J-J. Lesage  

E-Print Network [OSTI]

Genetic algorithms for delays evaluation in networked automation systems B. Addad n , S. Amari, J-J. Lesage Automated Production Research Laboratory LURPA, ENS-Cachan, 61 av. du Pre´sident Wilson, 94235 form 15 September 2010 Accepted 19 October 2010 Keywords: Networked automation systems Switched packets

Paris-Sud XI, Université de

162

Development and Evaluation of an Automated Annotation Pipeline and cDNA Annotation System  

E-Print Network [OSTI]

Development and Evaluation of an Automated Annotation Pipeline and cDNA Annotation System Takeya, including an automated annotation pipeline that provides high-quality preliminary annotation for each

Gough, Julian

163

Building integrated photovoltaic systems analysis: Preliminary report  

SciTech Connect (OSTI)

The National Renewable Energy Laboratory (NREL) has estimated that the deployment of photovoltaics (PV) in the commercial buildings sector has the potential to contribute as much as 40 gigawatts peak electrical generation capacity and displace up to 1.1 quads of primary fuel use. A significant portion of this potential exists for smaller buildings under 25,000 square feet (2,300 square meters) in size or two stories or less, providing a strong cross over potential for residential applications as well. To begin to achieve this potential, research is needed to define the appropriate match of PV systems to energy end-uses in the commercial building sector. This report presents preliminary findings for a technical assessment of several alternative paths to integrate PV with building energy systems.

none,

1993-08-01T23:59:59.000Z

164

Veri cation of Automated Vehicle Protection Systems  

E-Print Network [OSTI]

such as PRT 2000TM, a system currently being developed at Raytheon. Due to their safety critical nature, PRT]. Raytheon engineers are currently working on the design and development of a new PRT system called PRT 2000-4033 and F19628-95-C-0118. zNorman M Delisle@ccmail.ed.ray.com. Raytheon Company, 1001 Boston Post Road

Lynch, Nancy

165

Assessment of the Applicability of Cooperative Vehicle-Highway Automation Systems to Bus Transit and Intermodal Freight: Case Study Feasibility Analyses in the Metropolitan Chicago Region  

E-Print Network [OSTI]

it is a form of vehicle automation that could be implementedare developed. For full automation, vehicle-roadway wirelessof Cooperative Vehicle-Highway Automation Systems to Bus

2004-01-01T23:59:59.000Z

166

Hanford site Computer Automated Mapping Information System (CAMIS)  

SciTech Connect (OSTI)

The Computer Automated Mapping Information System (CAMIS) provides sitewide, networked access to CAD based geographically referenced data. CAMIS allows multiple organizations to maintain and share their data. Information collected and managed according to site-wide standards, enables each organization to focus their limited resources on data issues tied to their own discipline without having to collect or manage reference data outside their respective domains. Sharing information also minimizes redundant data and helps improve the overall quality of the sites` data resources.

Rush, S.F. [ICF Kaiser Hanford Co., Richland, WA (United States)

1995-09-01T23:59:59.000Z

167

An automated miniature robotic vehicle inspection system  

SciTech Connect (OSTI)

A novel, autonomous reconfigurable robotic inspection system for quantitative NDE mapping is presented. The system consists of a fleet of wireless (802.11g) miniature robotic vehicles, each approximately 175 × 125 × 85 mm with magnetic wheels that enable them to inspect industrial structures such as storage tanks, chimneys and large diameter pipe work. The robots carry one of a number of payloads including a two channel MFL sensor, a 5 MHz dry coupled UT thickness wheel probe and a machine vision camera that images the surface. The system creates an NDE map of the structure overlaying results onto a 3D model in real time. The authors provide an overview of the robot design, data fusion algorithms (positioning and NDE) and visualization software.

Dobie, Gordon; Summan, Rahul; MacLeod, Charles; Pierce, Gareth; Galbraith, Walter [Centre for Ultrasonic Engineering, University of Strathclyde, 204 George Street, Glasgow, G1 1XW (United Kingdom)

2014-02-18T23:59:59.000Z

168

High-performance commercial building systems  

SciTech Connect (OSTI)

This report summarizes key technical accomplishments resulting from the three year PIER-funded R&D program, ''High Performance Commercial Building Systems'' (HPCBS). The program targets the commercial building sector in California, an end-use sector that accounts for about one-third of all California electricity consumption and an even larger fraction of peak demand, at a cost of over $10B/year. Commercial buildings also have a major impact on occupant health, comfort and productivity. Building design and operations practices that influence energy use are deeply engrained in a fragmented, risk-averse industry that is slow to change. Although California's aggressive standards efforts have resulted in new buildings designed to use less energy than those constructed 20 years ago, the actual savings realized are still well below technical and economic potentials. The broad goal of this program is to develop and deploy a set of energy-saving technologies, strategies, and techniques, and improve processes for designing, commissioning, and operating commercial buildings, while improving health, comfort, and performance of occupants, all in a manner consistent with sound economic investment practices. Results are to be broadly applicable to the commercial sector for different building sizes and types, e.g. offices and schools, for different classes of ownership, both public and private, and for owner-occupied as well as speculative buildings. The program aims to facilitate significant electricity use savings in the California commercial sector by 2015, while assuring that these savings are affordable and promote high quality indoor environments. The five linked technical program elements contain 14 projects with 41 distinct R&D tasks. Collectively they form a comprehensive Research, Development, and Demonstration (RD&D) program with the potential to capture large savings in the commercial building sector, providing significant economic benefits to building owners and health and performance benefits to occupants. At the same time this program can strengthen the growing energy efficiency industry in California by providing new jobs and growth opportunities for companies providing the technology, systems, software, design, and building services to the commercial sector. The broad objectives across all five program elements were: (1) To develop and deploy an integrated set of tools and techniques to support the design and operation of energy-efficient commercial buildings; (2) To develop open software specifications for a building data model that will support the interoperability of these tools throughout the building life-cycle; (3) To create new technology options (hardware and controls) for substantially reducing controllable lighting, envelope, and cooling loads in buildings; (4) To create and implement a new generation of diagnostic techniques so that commissioning and efficient building operations can be accomplished reliably and cost effectively and provide sustained energy savings; (5) To enhance the health, comfort and performance of building occupants. (6) To provide the information technology infrastructure for owners to minimize their energy costs and manage their energy information in a manner that creates added value for their buildings as the commercial sector transitions to an era of deregulated utility markets, distributed generation, and changing business practices. Our ultimate goal is for our R&D effort to have measurable market impact. This requires that the research tasks be carried out with a variety of connections to key market actors or trends so that they are recognized as relevant and useful and can be adopted by expected users. While some of this activity is directly integrated into our research tasks, the handoff from ''market-connected R&D'' to ''field deployment'' is still an art as well as a science and in many areas requires resources and a timeframe well beyond the scope of this PIER research program. The TAGs, PAC and other industry partners have assisted directly in this effort

Selkowitz, Stephen

2003-10-01T23:59:59.000Z

169

Crusader Automated Docking System Phase 3 report  

SciTech Connect (OSTI)

The US Army is developing the next generation of battlefield artillery vehicles, including an advanced, self-propelled howitzer and a companion resupply vehicle. The resupply vehicle is intended to rendezvous with the howitzer near the battlefront and to upload ammunition to the howitzer. The Army has recommended that the vehicles incorporate robotics to increase safety, by allowing the crew to remain inside their vehicles during resupply operations. Oak Ridge National Laboratory has developed an autonomous docking system for a 6-D.F. robotic, ammunition transfer arm. The docking system augments the operator`s abilities by determining the position and orientation (pose) of a docking port. The pose is the location of the x, y, and z reference axes in 3-D space; and the orientation is the rotations--roll, pitch, and yaw--about those axes. Bye precisely determining the pose of the docking port, the robot can be instructed to move to the docking position without operator intervention. The system uses a video camera and frame grabber to digitize images of the special docking port. Custom algorithms were developed to recognize the port in the camera image, to determine the pose from its image features, and to distribute the results to the robot control computer. The system is loosely coupled to the robot and can be easily adapted to different mechanical configurations. The system has successfully demonstrated autonomous docking on a 24-in. tabletop robot and a 12-ft ammunition resupply robot. The update rate, measurement accuracy, continuous operation, and accuracy with obstructed view have been determined experimentally.

Jatko, W.B.; Goddard, J.S.; Ferrell, R.K.; Gleason, S.S.; Hicks, J.S.; Varma, V.K.

1996-03-01T23:59:59.000Z

170

Vision-based Control of a Smart Wheelchair for the Automated Transport and Retrieval System (ATRS)  

E-Print Network [OSTI]

for autonomously docking a wheelchair onto a vehicle lift platform. This is a principle component of the AutomatedVision-based Control of a Smart Wheelchair for the Automated Transport and Retrieval System (ATRS disabilities. The ATRS employs robotics, automation, and machine vision technologies, and can be integrated

Spletzer, John R.

171

Control Design of an Automated Highway System Roberto Horowitz and Pravin Varaiya  

E-Print Network [OSTI]

vehicle driving decisions to the driver. It is argued in [42] that full automation can greatly increase/h), the vehicles must be fully automated, since people cannot react quickly enough to drive safely with such smallControl Design of an Automated Highway System Roberto Horowitz and Pravin Varaiya University

Varaiya, Pravin

172

1D AND 3D SYSTEMS IN MACHINE AUTOMATION Dr.-Ing. Werner Stempfhuber  

E-Print Network [OSTI]

1D AND 3D SYSTEMS IN MACHINE AUTOMATION Dr.-Ing. Werner Stempfhuber Leica Geosystems AG Heerbrugg with "stringless technology". Today there is a large range of potential markets for new machine automation, mining and agricultural industries. The use of machine automation in these applications will alter

173

Human-Automation Collaboration in Complex Multivariate Resource Allocation Decision Support Systems  

E-Print Network [OSTI]

1 Human-Automation Collaboration in Complex Multivariate Resource Allocation Decision Support Systems M.L. Cummings* Sylvain Bruni Humans and Automation Laboratory 77 Massachusetts Ave, 33 uncertainty, typical of supervisory control environments, it is critical that some balance of human-automation

Cummings, Mary "Missy"

174

Recent Developments of the Modelica "Buildings" Library for Building Energy and Control Systems  

E-Print Network [OSTI]

Recent Developments of the Modelica "Buildings" Library for Building Energy and Control Systems 94720, USA Abstract At the Modelica 2009 conference, we introduced the Buildings library, a freely develop an open-source Modelica library for building en- ergy and control systems. The library is freely

175

Open Automated Demand Response Technologies for Dynamic Pricing and Smart Grid  

E-Print Network [OSTI]

for Automated Demand Response in Commercial Buildings. ” InAutomated Demand Response for Small Commercial Buildings. ”in automated demand response programs with building control

Ghatikar, Girish

2010-01-01T23:59:59.000Z

176

Development of a Model Specification for Performance MonitoringSystems for Commercial Buildings  

SciTech Connect (OSTI)

The paper describes the development of a model specification for performance monitoring systems for commercial buildings. The specification focuses on four key aspects of performance monitoring: (1) performance metrics; (2) measurement system requirements; (3) data acquisition and archiving; and (4) data visualization and reporting. The aim is to assist building owners in specifying the extensions to their control systems that are required to provide building operators with the information needed to operate their buildings more efficiently and to provide automated diagnostic tools with the information required to detect and diagnose faults and problems that degrade energy performance. The paper reviews the potential benefits of performance monitoring, describes the specification guide and discusses briefly the ways in which it could be implemented. A prototype advanced visualization tool is also described, along with its application to performance monitoring. The paper concludes with a description of the ways in which the specification and the visualization tool are being disseminated and deployed.

Haves, Philip; Hitchcock, Robert J.; Gillespie, Kenneth L.; Brook, Martha; Shockman, Christine; Deringer, Joseph J.; Kinney,Kristopher L.

2006-08-01T23:59:59.000Z

177

Green Building Certification Systems Requirement for New Federal...  

Energy Savers [EERE]

greenblgcert.docx More Documents & Publications EA-1991: Final Environmental Assessment Green Building Certification Systems Requirement for New Federal Buildings and Major...

178

Green Building Certification Systems Requirement for New Federal...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

CFR Parts 433, 435 and 436. greenblgcertcompare2014.docx More Documents & Publications Green Building Certification Systems Requirement for New Federal Buildings and Major...

179

Are CHP Systems Ready for Commercial Buildings?  

SciTech Connect (OSTI)

This paper highlights challenges associated with integration of CHP systems with existing buildings and maintaining their performance over time. The paper also identifies key research and development needs to address the challenges, so that CHP technologies can deliver the promised performance and reach their full potential market penetration.

Katipamula, Srinivas; Brambley, Michael R.; Zaltash, Abdi; Sands, Jim

2005-06-27T23:59:59.000Z

180

PV Integration by Building Energy Management System  

E-Print Network [OSTI]

. However, to validate global control algorithms, a simulator capable of interoperating with energy[kWh]. Econs (k) Total energy consumed by the load [kWh]. E (i, k) Energy consumed by the service i duringPV Integration by Building Energy Management System Rim.Missaoui¹, Ghaith.Warkozek¹, Seddik. Bacha

Boyer, Edmond

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Design and Operation of an Open, Interoperable Automated Demand Response Infrastructure for Commercial Buildings  

SciTech Connect (OSTI)

This paper describes the concept for and lessons from the development and field-testing of an open, interoperable communications infrastructure to support automated demand response (auto-DR). Automating DR allows greater levels of participation, improved reliability, and repeatability of the DR in participating facilities. This paper also presents the technical and architectural issues associated with auto-DR and description of the demand response automation server (DRAS), the client/server architecture-based middle-ware used to automate the interactions between the utilities or any DR serving entity and their customers for DR programs. Use case diagrams are presented to show the role of the DRAS between utility/ISO and the clients at the facilities.

Piette, Mary Ann; Ghatikar, Girish; Kiliccote, Sila; Watson, David; Koch, Ed; Hennage, Dan

2009-05-01T23:59:59.000Z

182

Department of Environmental Conservation, University of Massachusetts-Amherst Concentration in Building Systems 1  

E-Print Network [OSTI]

systems but encompasses specialized training in fields such as green building, structural timber design sensitive building materials & systems (green building); wood-concrete composite systems; innovative in Building Systems 1 Environmental Conservation Graduate Program Building Systems Concentration A

Schweik, Charles M.

183

A Pattern-Based Coordination and Test Framework for Multi-Agent Simulation of Production Automation Systems  

E-Print Network [OSTI]

A Pattern-Based Coordination and Test Framework for Multi-Agent Simulation of Production Automation Integration for Flexible Automation Systems, Austria {thomas.moser, stefan.biffl}@tuwien.ac.at 2 Automation automation systems consist of many entities (like robots and shuttles) that interact in complex ways

184

Whole-building systems integration laboratory survey  

SciTech Connect (OSTI)

This report was prepared for the Pacific Northwest Laboratory as a subcontracted activity by the Research Management Foundation of the American Consulting Engineers Council. The objective of the survey reported herein was to independently assess the need for a Building System Integration Laboratory from the viewpoint of academicians in the field of building science. The subcontractor-developed questionnaire was sent to 200 professors of architecture and engineering at US universities. In view of this diverse population, the 10% rate of return on the questionnaire was considered acceptable. Although the responses probably do not reflect an unbiased summary of the collective perceptions of the original population surveyed, they do provide a valid insight into the interests and concerns of the academic community with respect to building sciences issues.

Crawley, D.B. (American Consulting Engineers Council, Washington, DC (USA). Research and Management Foundation)

1989-09-01T23:59:59.000Z

185

The dynamics of 'systems building' : An analysis of process mutations  

E-Print Network [OSTI]

This thesis investigates systems building in architecture. As the systems approach is an organized process for problem solving, the understanding of structural and functional relationships is essential. As systems building ...

Paul, Rathindra Jurg

1984-01-01T23:59:59.000Z

186

Critical Simulation Based Evaluation of Thermally Activated Building Systems (TABS) Design Models  

E-Print Network [OSTI]

building systems for low energy buildings: System analysismeasurement of six low energy buildings in different partspointed out that low energy buildings may under- perform

Basu, Chandrayee

2012-01-01T23:59:59.000Z

187

Field Demonstration of Automated Demand Response for Both Winter and  

E-Print Network [OSTI]

) is a demand-side management strategy to reduce electricity use during times of high peak electric loads;1 Field Demonstration of Automated Demand Response for Both Winter and Summer Events in Large Buildings of a series of field test of automated demand response systems in large buildings in the Pacific Northwest

188

automated insulin-delivery systems: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Ioannou A, utomatic is todesign and test avehicle control system in order toachieve full vehicle automation in the longitudinal vehicle following isan important feature of a fully...

189

E-Print Network 3.0 - automated manufacturing systems Sample...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

by delighting the customers. IIMC Manufacturing Systems & Technology Manufacturing... in manufacturing, Awareness of green production and Big R in manufacturing IIT Automation &...

190

E-Print Network 3.0 - automated triage system Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

prioritizing a stream of low-level device health Summary: for improving the alarm triage process. However, as with all automation, machine-learning-based systems... can be...

191

Open Automated Demand Response Communications Specification (Version 1.0)  

E-Print Network [OSTI]

Keywords: demand response, buildings, electricity use, Interface  Automated Demand Response  Building Automation of demand response in  commercial buildings.   One key 

Piette, Mary Ann

2009-01-01T23:59:59.000Z

192

Automation of Pivot Sprinkler Irrigation Systems to More Efficiently Utilize Rainfall and Irrigation Water  

E-Print Network [OSTI]

A study was conducted to develop automated pivot sprinkler irrigation systems and determine if such systems use less water and energy than manually operated systems. The study was conducted near Earth, Texas, using irrigation systems located...

Wendt, C. W.; Runkles, J. R.; Gerst, M. D.; Harbert, H. P. III; Hutmacher, R. B.

193

Systems for home automation are a necessary component for intelligent smart homes applications.  

E-Print Network [OSTI]

describe a smart home-heating system that is under development. Construct collects the inputs fromAbstract Systems for home automation are a necessary component for intelligent smart homes to provide semantically rich unification over a range of home- and web-based automation systems. 1

Dobson, Simon

194

An automated system for measuring gas production from forages inoculated with rumen uid and its use  

E-Print Network [OSTI]

An automated system for measuring gas production from forages inoculated with rumen ¯uid and its the principles of the gas production technique and provide examples of how the automated system has been used of different systems have been used to measure gas production. Menke et al. (1979) described a method in which

Griffith, Gareth

195

Automated cassette-to-cassette substrate handling system  

DOE Patents [OSTI]

An automated cassette-to-cassette substrate handling system includes a cassette storage module for storing a plurality of substrates in cassettes before and after processing. A substrate carrier storage module stores a plurality of substrate carriers. A substrate carrier loading/unloading module loads substrates from the cassette storage module onto the plurality of substrate carriers and unloads substrates from the plurality of substrate carriers to the cassette storage module. A transport mechanism transports the plurality of substrates between the cassette storage module and the plurality of substrate carriers and transports the plurality of substrate carriers between the substrate carrier loading/unloading module and a processing chamber. A vision system recognizes recesses in the plurality of substrate carriers corresponding to empty substrate positions in the substrate carrier. A processor receives data from the vision system and instructs the transport mechanism to transport substrates to positions on the substrate carrier in response to the received data.

Kraus, Joseph Arthur; Boyer, Jeremy James; Mack, Joseph; DeChellis, Michael; Koo, Michael

2014-03-18T23:59:59.000Z

196

A Mobile Automated Tomographic Gamma Scanning System - 13231  

SciTech Connect (OSTI)

Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transport container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 keV/channel resolution to support both isotopic analysis with the MGA/MGAU software and a wide 3 MeV dynamic range. The calibration and verification of the system is discussed, and quantitative results are presented for a variety of drum types and matrices. (authors)

Kirkpatrick, J.M.; LeBlanc, P.J.; Nakazawa, D.; Petroka, D.L.; Kane Smith, S.; Venkataraman, R.; Villani, M. [Canberra Industries, Inc. 800 Research Parkway, Meriden CT 06450 (United States)] [Canberra Industries, Inc. 800 Research Parkway, Meriden CT 06450 (United States)

2013-07-01T23:59:59.000Z

197

Pitfalls in Building and HVAC Systems  

E-Print Network [OSTI]

the summer savings. ? Consider all forms of savings, not just en ergy. Opportunities are often missed be cause only energy savings are consideted. For example, the installation of extetior wall insulation or aluminum thermopane win dows result in a...PITFALLS IN BUILDING AND HVAC SYSTEMS B. N. Gidwani, P.E. Roy F. Weston, Inc. West Chester, Pennsylvania ABSTRACT The purpose of an energy audit is to identify and analyze areas of energy consumption and to pro pose methods of conservation...

Gidwani, B. N.

198

Automated Measurement and Signaling Systems for the Transactional Network  

E-Print Network [OSTI]

Demand Response and Energy Efficiency in Commercial Buildings.of Demand Response measures in the test building. They areBuilding Electricity Use, with Application to Demand Response,

Piette, Mary Ann

2014-01-01T23:59:59.000Z

199

Building America Webinar: Central Multifamily Water Heating Systems...  

Energy Savers [EERE]

Building America Webinar: Central Multifamily Water Heating Systems Building America Webinar: Central Multifamily Water Heating Systems January 21, 2015 11:00AM to 12:30PM MST...

200

Building America Webinar: Central Multifamily Water Heating Systems...  

Energy Savers [EERE]

Building America Webinar: Central Multifamily Water Heating Systems Building America Webinar: Central Multifamily Water Heating Systems January 21, 2015 3:00PM to 4:30PM EST This...

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Enforcing Safety Requirements for Industrial Automation Systems at Runtime Position Paper  

E-Print Network [OSTI]

Engineering Integration for Flexible Automation Systems" Vienna University of Technology Vienna, Austria. Hence, the need exists to capture and manage safe- ty requirements at design time and runtime, since elicitation. I. INTRODUCTION Complex industrial automation systems, such as manu- facturing plants, power

202

Hybrid Control Network Intrusion Detection Systems for Automated Power Distribution Systems  

E-Print Network [OSTI]

) for protecting automated distribution systems (ADS) against certain types of cyber attacks in a new way, distribution au- tomation, network security, intrusion detection systems. I. INTRODUCTION A. Scope and Goals their development with that of an appropriate cyber security frame- work that would prevent attackers from gaining

Peisert, Sean

203

Demo: BACChat: A Building Automation Control Client for Sensor Data Collection  

E-Print Network [OSTI]

% of the total energy usage in the United States while the rest goes to transportation and industry [1]. In some and residential buildings in energy consumption is even higher (in Hong Kong 2008, the figure is 65% [2]). As such (BMS), which plays a key role in maintaining the operation, energy efficiency, and safety of a building

Wang, Dan

204

Index to Evaluate Energy Efficiency of the Building HVAC System  

E-Print Network [OSTI]

1An Index to Evaluate Energy Efficiency of the Entire Building HVAC System Presented by Dr. Claridge Date: 09/15/2014 ESL-IC-14-09-15 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14..., Beijing, China, September 14-17, 2014 3• Why we need the Energy/Load Ratio 1. Building 2. HVAC Systems 3. Common Index • Building sector consumes 40% of total energy usage in US (Residential buildings – 22%, Commercial building – 19%) • HVAC systems...

Wang, L.; Wang, L.; Claridge,D.

2014-01-01T23:59:59.000Z

205

Integrated Energy Systems (IES) for Buildings: A Market Assessment...  

Broader source: Energy.gov (indexed) [DOE]

Energy Systems (IES) for Buildings: A Market Assessment, September 2002 Integrated Energy Systems (IES) combine on-site power or distributed generation technologies with thermally...

206

Building Energy Information Systems: User Case Studies  

E-Print Network [OSTI]

building to outside entities, supporting and aligning with current developments in demand side management,

Granderson, Jessica

2010-01-01T23:59:59.000Z

207

Innovative Faade Systems for Low-energy Commercial Buildings  

E-Print Network [OSTI]

Innovative Façade Systems for Low-energy Commercial Buildings Eleanor Lee, Stephen Selkowitz abstract Glazing and façade systems have very large impacts on all aspects of commercial building for commercial buildings to significantly reduce energy and demand, helping to move us toward our goal of net

208

Evaluation of Response Time in Ethernet-based Automation Systems Galle Marsal, Bruno Denis, Jean-Marc Faure  

E-Print Network [OSTI]

Evaluation of Response Time in Ethernet-based Automation Systems Gaëlle Marsal, Bruno Denis, Jean@eit.uni-kl.de Abstract This paper presents a method to assess response time of automation system architectures including design of automation systems including this kind of industrial Ethernet networks. 1. Introduction Many

Paris-Sud XI, Université de

209

40 IEEE TRANSACTIONS ON INTELLIGENT TRANSPORTATION SYSTEMS, VOL. 1, NO. 1, MARCH 2000 Designing Human-Centered Automation: Tradeoffs  

E-Print Network [OSTI]

-centered automation in advanced vehicle systems, the decision method identifies performance valuations and compares--Advanced vehicle systems, decision making, human-centered automation, human factors, satisficing. I. INTRODUCTION Human-Centered Automation: Tradeoffs in Collision Avoidance System Design Michael A. Goodrich, Member

Goodrich, Michael A.

210

Development of Mechanical Systems for Automated Medical Slide Specimen Storage and Retrieval  

E-Print Network [OSTI]

and intriguing considering that improving medical systems can save the lives of patients. The Intelligent System and Automation Laboratory at the University of Kansas has created a prototype machine with the goal of making the process of medical slide specimen...

Wurtz, Joshua James

2014-05-31T23:59:59.000Z

211

Development of control system to automate the PCB pin insertion process  

E-Print Network [OSTI]

This thesis describes the development of the control system that runs the automated pin insertion machine in a surface mount technology assembly line. The control system is divided into 2 subsystems viz. pin sorting and ...

Isaac, Rejin

2012-01-01T23:59:59.000Z

212

Buildings and corporate strategy : towards a management system model  

E-Print Network [OSTI]

This thesis focuses on buildings as a subject of attention and inquiry in a corporate setting. It attempts to draw implications for the design of a management system to deal with the special nature of buildings as a resource. ...

Brana, Rodrigo

1985-01-01T23:59:59.000Z

213

Energy management systems for commercial buildings. Final report  

SciTech Connect (OSTI)

Increasing costs of energy and the development of lower cost microelectronics have created a growing market for energy management systems applied to commercial buildings. This report examines the spectrum of EMS available and how they are used in different types of commercial buildings. An informal survey of 197 commercial building owners provided additional information on EMS installed and the energy savings attributed to those systems. Evaluations were performed to identify types of EMS appropriate to specific types of commercial buildings.

Woody, A.W.

1986-02-01T23:59:59.000Z

214

Building Energy Information Systems: User Case Studies  

SciTech Connect (OSTI)

Measured energy performance data are essential to national efforts to improve building efficiency, as evidenced in recent benchmarking mandates, and in a growing body of work that indicates the value of permanent monitoring and energy information feedback. This paper presents case studies of energy information systems (EIS) at four enterprises and university campuses, focusing on the attained energy savings, and successes and challenges in technology use and integration. EIS are broadly defined as performance monitoring software, data acquisition hardware, and communication systems to store, analyze and display building energy information. Case investigations showed that the most common energy savings and instances of waste concerned scheduling errors, measurement and verification, and inefficient operations. Data quality is critical to effective EIS use, and is most challenging at the subsystem or component level, and with non-electric energy sources. Sophisticated prediction algorithms may not be well understood but can be applied quite effectively, and sites with custom benchmark models or metrics are more likely to perform analyses external to the EIS. Finally, resources and staffing were identified as a universal challenge, indicating a need to identify additional models of EIS use that extend beyond exclusive in-house use, to analysis services.

Granderson, Jessica; Piette, Mary Ann; Ghatikar, Girish

2010-03-22T23:59:59.000Z

215

A View on Future Building System Modeling and Simulation  

SciTech Connect (OSTI)

This chapter presents what a future environment for building system modeling and simulation may look like. As buildings continue to require increased performance and better comfort, their energy and control systems are becoming more integrated and complex. We therefore focus in this chapter on the modeling, simulation and analysis of building energy and control systems. Such systems can be classified as heterogeneous systems because they involve multiple domains, such as thermodynamics, fluid dynamics, heat and mass transfer, electrical systems, control systems and communication systems. Also, they typically involve multiple temporal and spatial scales, and their evolution can be described by coupled differential equations, discrete equations and events. Modeling and simulating such systems requires a higher level of abstraction and modularisation to manage the increased complexity compared to what is used in today's building simulation programs. Therefore, the trend towards more integrated building systems is likely to be a driving force for changing the status quo of today's building simulation programs. Thischapter discusses evolving modeling requirements and outlines a path toward a future environment for modeling and simulation of heterogeneous building systems.A range of topics that would require many additional pages of discussion has been omitted. Examples include computational fluid dynamics for air and particle flow in and around buildings, people movement, daylight simulation, uncertainty propagation and optimisation methods for building design and controls. For different discussions and perspectives on the future of building modeling and simulation, we refer to Sahlin (2000), Augenbroe (2001) and Malkawi and Augenbroe (2004).

Wetter, Michael

2011-04-01T23:59:59.000Z

216

A Modular Building Controls Virtual Test Bed for the Integrations of Heterogeneous Systems  

SciTech Connect (OSTI)

This paper describes the Building Controls Virtual Test Bed (BCVTB) that is currently under development at Lawrence Berkeley National Laboratory. An earlier prototype linked EnergyPlus with controls hardware through embedded SPARK models and demonstrated its value in more cost-effective envelope design and improved controls sequences for the San Francisco Federal Building. The BCVTB presented here is a more modular design based on a middleware that we built using Ptolemy II, a modular software environment for design and analysis of heterogeneous systems. Ptolemy II provides a graphical model building environment, synchronizes the exchanged data and visualizes the system evolution during run-time. Our additions to Ptolemy II allow users to couple to Ptolemy II a prototype version of EnergyPlus,MATLAB/Simulink or other simulation programs for data exchange during run-time. In future work we will also implement a BACnet interface that allows coupling BACnet compliant building automation systems to Ptolemy II. We will present the architecture of the BCVTB and explain how users can add their own simulation programs to the BCVTB. We will then present an example application in which the building envelope and the HVAC system was simulated in EnergyPlus, the supervisory control logic was simulated in MATLAB/Simulink and Ptolemy II was used to exchange data during run-time and to provide realtime visualization as the simulation progresses.

Wetter, Michael; Wetter, Michael; Haves, Philip

2008-06-30T23:59:59.000Z

217

Building Thermal Envelope Systems and Materials (BTESM) progress report for DOE Office of Buildings Energy Research  

SciTech Connect (OSTI)

The Monthly Report of the Building Thermal Envelope Systems and Materials (BTESM) Program is a monthly update of both in-house ORNL projects and subcontract activities in the research areas of building materials, wall systems, foundations, roofs, building diagnostics, and research utilization and technology transfer. Presentations are not stand-alone paragraphs every month. Their principal values are the short-time lapse between accomplishment and reporting and their evolution over a period of several months.

Burn, G. (comp.)

1990-01-01T23:59:59.000Z

218

EuroSPI 2009 -1 Software provides an increasing part of the added value of modern automation systems and  

E-Print Network [OSTI]

automation systems and thus becomes more complex. System requirements may change even late in the development process, lead to ad-hoc modifications of the product and require systematic (and automated) testing approaches. However, unit tests for automation software have to consider the interac- tion with hardware

219

Intelligent Building Energy Information and Control Systems for Low-Energy Operations and Optimal Demand Response  

E-Print Network [OSTI]

As  we  develop low?energy buildings, the need for models Building Energy Information and Control Systems for Low-Building  Energy  Information  and  Control  Systems  for  Low­

Piette, Mary Ann

2014-01-01T23:59:59.000Z

220

Automated Surface Observing System (ASOS) General System Description  

E-Print Network [OSTI]

Generator System $ 4,300 135 $ 580,500 Hydrogen Fuel Cell $ 5,500 135 $ 742,500 4 #12;Life Cycle Cost;ACU Option Comparison Battery Bank to power Hydrogen Fuel Engine Generator the existing UPS Cell at 884 sites nationwide, normally at airports · System has two distinct subsystems: Field installed

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Final Report on Retrospective Testing and Application of an Automated Building Commissioning Analysis Tool (ABCAT)  

E-Print Network [OSTI]

simulation model used was calibrated to the building energy consumption data in a baseline period. Then, the model was used to predict the optimal cooling and heating consumption in the following days. A cumulative energy difference plot is the primary fault...

Bynum, John; Lin, Guanjing; Claridge, David

222

System-Level Monitoring and Diagnosis of Building HVAC System  

E-Print Network [OSTI]

Y. Shu, Building envelope regulations on thermal comfort inof the building envelope on indoor thermal behavior, serveof the building envelope on indoor thermal behavior. This is

Wu, Siyu

2013-01-01T23:59:59.000Z

223

Systems building of short span precast concrete bridges  

E-Print Network [OSTI]

SYSTEMS BUILDING OF SHORT SPAN PRECAST CONCRETE BRIDGES A Thesis by MARVIN STEELE Submitted to the Graduate College of Texas AIIM University in partial fulfillment of the requirement for the degree of MASTER OF SCIENCE May 1975 Major... Subject: Civil Engineering SYSTEMS BUILDING OF SHORT SPAN PRECAST CONCRETE BRIDGES A Thesis by MARVIN STEELE Aoproved as to style and content by: (Chairman of Committee) (Head of Department ( mber) fi (Member) May 1975 ABSTRACT Systems Building...

Steele, Marvin

1975-01-01T23:59:59.000Z

224

Lateral control of articulated vehicles for automated highway systems under uncertainty in vehicle parameters  

E-Print Network [OSTI]

Studied in this thesis is the formulation of lateral control algorithms for articulated vehicles performing a lane following maneuver on Automated Highway Systems (AHS). A steering control algorithm using the input/output linearization scheme...

Daud, Omar

1998-01-01T23:59:59.000Z

225

Design and prototype of an automated system for commercially viable production using micro contact printing  

E-Print Network [OSTI]

This dissertation is a documentation of the thought process, its justification and the implementation details that went into prototyping a fully automated system employing Micro Contact Printing, an emerging technique for ...

Chauhan, Karan

2006-01-01T23:59:59.000Z

226

Human-Automation Collaboration in Complex Multivariate Resource Allocation Decision Support Systems  

E-Print Network [OSTI]

In resource allocation problems for systems with moving planning horizons and significant uncertainty, typical of supervisory control environments, it is critical that some balance of human-automation collaboration be ...

Cummings, M.L.

2010-01-01T23:59:59.000Z

227

Automation of airlift scheduling for the upgraded command and control system of military airlift command  

E-Print Network [OSTI]

This report describes a conceptual design for automation of the scheduling of airlift activities as part of the current upgrade of the MAC C2 System. It defines the airlift scheduling problem in generic terms before reviewing ...

Simpson, R. W.

1984-01-01T23:59:59.000Z

228

E-Print Network 3.0 - advanced automation system air traffic...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

burdened air traffic control (ATC) systems that are at or near their desig- nated maximum handling... of ground-based ATC but to use automation to support air traffic...

229

An automated tool for evaluating compliance and providing assistance with building energy standards during design  

SciTech Connect (OSTI)

In an effort to encourage the maximum cost-effective level of energy efficiency in new building design, energy-efficiency standards have become more location-specific and performance-based. As a result, standards often provide more than one path for ensuring and demonstrating that a design complies, but at the cost of increased complexity. In addition, the burden of remedying a noncompliant design rests on the designers' knowledge and experience, with only general guidance provided by the standards. As part of efforts in the US Department of Energy's (DOE's) Advanced Energy Design and Operation Technologies (AEDOT) project, a team at DOE's Pacific Northwest Laboratory is developing a computer program known as the Energy Standards Intelligent Design Tool (ES-IDT). The ES-IDT is one component of a prototype computer-based building design environment. It performs automatic compliance checking for parts of ASHRAE/IES Standard 90.1-1989 and provides designers assistance in bringing noncomplying designs into compliance. This paper describes the ES-IDT, the functions it provides, and how it is integrated into the design process via the AEDOT prototype building design environment. 9 refs.

Quadrel, R.W.; Brambley, M.R.; Stratton, R.C.

1992-04-30T23:59:59.000Z

230

An automated tool for evaluating compliance and providing assistance with building energy standards during design  

SciTech Connect (OSTI)

In an effort to encourage the maximum cost-effective level of energy efficiency in new building design, energy-efficiency standards have become more location-specific and performance-based. As a result, standards often provide more than one path for ensuring and demonstrating that a design complies, but at the cost of increased complexity. In addition, the burden of remedying a noncompliant design rests on the designers` knowledge and experience, with only general guidance provided by the standards. As part of efforts in the US Department of Energy`s (DOE`s) Advanced Energy Design and Operation Technologies (AEDOT) project, a team at DOE`s Pacific Northwest Laboratory is developing a computer program known as the Energy Standards Intelligent Design Tool (ES-IDT). The ES-IDT is one component of a prototype computer-based building design environment. It performs automatic compliance checking for parts of ASHRAE/IES Standard 90.1-1989 and provides designers assistance in bringing noncomplying designs into compliance. This paper describes the ES-IDT, the functions it provides, and how it is integrated into the design process via the AEDOT prototype building design environment. 9 refs.

Quadrel, R.W.; Brambley, M.R.; Stratton, R.C.

1992-04-30T23:59:59.000Z

231

Fault Detection and Diagnosis in Building HVAC Systems.  

E-Print Network [OSTI]

??Building HVAC systems account for more than 30% of annual energy consumption in United States. However, it has become apparent that only in a small… (more)

Najafi, Massieh

2010-01-01T23:59:59.000Z

232

Technical and Energy Assessment of Building Integrated Photovoltaic Systems applied to the UAE Office Buildings  

E-Print Network [OSTI]

Technical and Energy Assessment of Building Integrated Photovoltaic Systems applied to the UAE Office Buildings Hassan Radhi Assistant Professor College of Engineering UAE University Al-Ain, United Arab Emirates ABSTRACT In the market... due to the PV panels represents an important factor when the EPBT is estimated Keywords: BiPV, embodied energy, UAE commercial buildings. INTRODUCTION Developments in the design and manufacture of photovoltaic cells have recently been a...

Radhi, H.

2010-01-01T23:59:59.000Z

233

Test Automation Test Automation  

E-Print Network [OSTI]

Test Automation Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2013 Mousavi: Test Automation #12;Test Automation Outline Test Automation Mousavi: Test Automation #12;Test Automation Why? Challenges of Manual Testing Test-case design: Choosing inputs

Mousavi, Mohammad

234

Analysis of Open Automated Demand Response Deployments in California and Guidelines to Transition to Industry Standards  

E-Print Network [OSTI]

Automated  Demand  Response  in  Commercial  Buildings.  Demand  Response  Infrastructure  for   Commercial  Buildings.  

Ghatikar, Girish

2014-01-01T23:59:59.000Z

235

Building America Systems Integration Research Annual Report: FY 2012  

SciTech Connect (OSTI)

This document is the Building America FY2012 Annual Report, which includes an overview of the Building America Program activities and the work completed by the National Renewable Energy Laboratory and the Building America industry consortia (the Building America teams). The annual report summarizes major technical accomplishments and progress towards U.S. Department of Energy Building Technologies Program's multi-year goal of developing the systems innovations that enable risk-free, cost effective, reliable and durable efficiency solutions that reduce energy use by 30%-50% in both new and existing homes.

Gestwick, M.

2013-05-01T23:59:59.000Z

236

Interfacing computer-assisted drafting and design with the building loads analysis and system thermodynamics (BLAST) program. Final report  

SciTech Connect (OSTI)

Energy efficient building design requires in-depth thermal analysis. Existing Computer Aided Design and Drafting (CADD) software packages already enhance the productivity and quality of design. Thermal analysis tools use much the same information as that contained in CADD drawings to determine the most energy efficient design configuration during the design process. To use these analysis tools, data already contained in the CADD system must be re-keyed into the analysis packages. This project created an interface to automate the migration of data from CADD to the Building Loads Analysis System and Thermodynamics (BLAST) analysis program, which is an Army-standard system for evaluating building energy performance. Two interfaces were developed, one batch-oriented (IN2BLAS7) and one interactive (the Drawing Navigator). Lessons learned from the development of IN2BLAST were carried into the development of the Drawing Navigator, and the Drawing Navigator was field tested. Feedback indicated that useful automation of the data migration is possible, and that proper application of such automation can increase productivity.... Blast, CADD, Interface, IN2BLAST, Drawing navigator.

Morton, J.D.; Pyo, C.; Choi, B.

1992-10-01T23:59:59.000Z

237

Optimal Control of Building HVAC Systems in the Presence of Imperfect Predictions  

E-Print Network [OSTI]

minimization of building hvac systems using model predictivealgorithm design for hvac systems in energy efficient build-optimal control design for HVAC systems,” in Dynamic System

Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2014-01-01T23:59:59.000Z

238

Cyber-Physical Energy Systems: Focus on Smart Buildings  

E-Print Network [OSTI]

of a deeply coupled system of energy usage, comfort and work derived. At a macroscale, buildings use approxi computers and laptops in offices and homes will exceed over 3x the energy use by all data centers combinedCyber-Physical Energy Systems: Focus on Smart Buildings Jan Kleissl Dept. of Mechanical

Gupta, Rajesh

239

Energy Consumption Analyses of Frequently-used HVAC System Types in High Performance Office Buildings.  

E-Print Network [OSTI]

??The high energy consumption of heating, ventilation and air-conditioning (HVAC) systems in commercial buildings is a hot topic. Office buildings, a typical building set of… (more)

Yan, Liusheng

2014-01-01T23:59:59.000Z

240

Indoor humidity and human health: part II--buildings and their systems  

E-Print Network [OSTI]

Northwest homes. Healthy Buildings: Proceeding of IAQ ’91,inside an HVAC system compatible with a healthy building?Healthy Buildings: Proceeding of IAQ ’91, September,

Arens, Edward A; Baughman, A.

1996-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

HPCBSHigh Performance Commercial Building Systems Amanda Potter, Hannah Friedman and Tudi Haasl,  

E-Print Network [OSTI]

HPCBSHigh Performance Commercial Building Systems Amanda Potter, Hannah Friedman and Tudi Haasl commercial building energy use. Although the success and cost-effectiveness of commissioning projects depends systems are becoming more prevalent in commercial buildings, yet building owners often find

242

NEW INDUSTRIAL AUTOMATION LABORATORY & COURSES ECET TECHONOLOGY PROGRAM ADVANCEMENT  

E-Print Network [OSTI]

, controllers and drives. Students design, simulate, build, test and document automation systems for Capstone equipment. 3. Measure vibration and power-line harmonic distortion. 4. Effectively identify, formulate of automation and electronics equipment provide the basis for new courses in technology and engineering

Allen, Gale

243

4.462 / 4.441 Building Technologies II: Building Structural Systems I, Spring 2003  

E-Print Network [OSTI]

This course serves as an introduction to the history, theory, and construction of basic structural systems with an introduction to energy issues in buildings. Emphasis is placed on developing an understanding of basic ...

Ochsendorf, John Allen

244

Automated monitoring functions for improved power system operation and control  

E-Print Network [OSTI]

process that is currently taking place between IEC 61850, IEC 61970 [2] and IEC 61968 [3]. This paper tracking · Automated analysis. The status tracking function provides additional level in the process such as Digital Fault Recorder (DFR) [7], Digital Protection Relay (DPR), Power Quality Meter (PQM) [8], Remote

245

Automated Non-Destructive Testing Array Evaluation System  

SciTech Connect (OSTI)

Utilities perform eddy current tests on nuclear power plant steam generator (SG) tubes to detect degradation. This report summarizes the status of ongoing research to develop signal processing algorithms that automate analysis of eddy current test data. The research focuses on analyzing array probe data for detecting, classifying, and characterizing degradation in SG tubes.

T.Wei, N.Zavaljevski, S.Bakhtiari, A.Miron, D.Kupperman

2004-12-31T23:59:59.000Z

246

Theoretical Minimum Energy Use of a Building HVAC System  

E-Print Network [OSTI]

This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air...

Tanskyi, O.

2011-01-01T23:59:59.000Z

247

An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

Developing an Integrated Building Design Tool by Couplingdesign energy efficient building systems in this complex setting, integrated

Trcka, Marija

2010-01-01T23:59:59.000Z

248

System-Level Monitoring and Diagnosis of Building HVAC System.  

E-Print Network [OSTI]

??Heating, ventilation, and air conditioning (HVAC) is an indoor environmental technology that is extensively instrumented for large-scale buildings. Among all subsystems of buildings, the HVAC… (more)

Wu, Siyu

2013-01-01T23:59:59.000Z

249

Automated fiber pigtailing machine  

DOE Patents [OSTI]

The Automated Fiber Pigtailing Machine (AFPM) aligns and attaches optical fibers to optoelectronic (OE) devices such as laser diodes, photodiodes, and waveguide devices without operator intervention. The so-called pigtailing process is completed with sub-micron accuracies in less than 3 minutes. The AFPM operates unattended for one hour, is modular in design and is compatible with a mass production manufacturing environment. This machine can be used to build components which are used in military aircraft navigation systems, computer systems, communications systems and in the construction of diagnostics and experimental systems. 26 figs.

Strand, O.T.; Lowry, M.E.

1999-01-05T23:59:59.000Z

250

Automated fiber pigtailing machine  

DOE Patents [OSTI]

The Automated Fiber Pigtailing Machine (AFPM) aligns and attaches optical fibers to optoelectonic (OE) devices such as laser diodes, photodiodes, and waveguide devices without operator intervention. The so-called pigtailing process is completed with sub-micron accuracies in less than 3 minutes. The AFPM operates unattended for one hour, is modular in design and is compatible with a mass production manufacturing environment. This machine can be used to build components which are used in military aircraft navigation systems, computer systems, communications systems and in the construction of diagnostics and experimental systems.

Strand, Oliver T. (Castro Valley, CA); Lowry, Mark E. (Castro Valley, CA)

1999-01-01T23:59:59.000Z

251

Building America Case Study: Balancing Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet)  

SciTech Connect (OSTI)

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

Not Available

2014-09-01T23:59:59.000Z

252

Disposable and removable nucleic acid extraction and purification cartridges for automated flow-through systems  

DOE Patents [OSTI]

Removable cartridges are used on automated flow-through systems for the purpose of extracting and purifying genetic material from complex matrices. Different types of cartridges are paired with specific automated protocols to concentrate, extract, and purifying pathogenic or human genetic material. Their flow-through nature allows large quantities sample to be processed. Matrices may be filtered using size exclusion and/or affinity filters to concentrate the pathogen of interest. Lysed material is ultimately passed through a filter to remove the insoluble material before the soluble genetic material is delivered past a silica-like membrane that binds the genetic material, where it is washed, dried, and eluted. Cartridges are inserted into the housing areas of flow-through automated instruments, which are equipped with sensors to ensure proper placement and usage of the cartridges. Properly inserted cartridges create fluid- and air-tight seals with the flow lines of an automated instrument.

Regan, John Frederick

2014-09-09T23:59:59.000Z

253

Design and Operation of an Open, Interoperable Automated Demand Response Infrastructure for Commercial Buildings  

E-Print Network [OSTI]

Power Research Institute (EPRI) IntelliGrid Consortium, “ThePower Delivery System,” EPRI, Jan. 2, http://www.epri.com/Power Research Institute (EPRI) that started in 2004. The

Piette, Mary Ann

2010-01-01T23:59:59.000Z

254

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond  

E-Print Network [OSTI]

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond Lawrence Berkeley of the commissioning of HVAC systems. The approach is based on software that generates a sequence of test signals for new and retrofit projects. Introduction The performance of many HVAC systems is limited more by poor

Diamond, Richard

255

Automated radioanalytical system for the determination of Sr-90 in  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr MayAtmospheric Optical Depth (AOD)ProductssondeadjustsondeadjustAboutScience Program Cumulus Humilis, 2014Automated Algorithmenvironmental

256

Scalable Distributed Automation System: Scalable Real-time Decentralized Volt/VAR Control  

SciTech Connect (OSTI)

GENI Project: Caltech is developing a distributed automation system that allows distributed generators—solar panels, wind farms, thermal co-generation systems—to effectively manage their own power. To date, the main stumbling block for distributed automation systems has been the inability to develop software that can handle more than 100,000 distributed generators and be implemented in real time. Caltech’s software could allow millions of generators to self-manage through local sensing, computation, and communication. Taken together, localized algorithms can support certain global objectives, such as maintaining the balance of energy supply and demand, regulating voltage and frequency, and minimizing cost. An automated, grid-wide power control system would ease the integration of renewable energy sources like solar power into the grid by quickly transmitting power when it is created, eliminating the energy loss associated with the lack of renewable energy storage capacity of the grid.

None

2012-03-01T23:59:59.000Z

257

Singapore's Zero-Energy Building's Daylight Monitoring System  

E-Print Network [OSTI]

LBNL-3708E Singapore's Zero-Energy Building's Daylight Monitoring System Author(s), L. Grobe; S thereof or The Regents of the University of California. #12;Singapore's Zero-Energy Building's daylight, 94720 California, USA 1. Abstract A setup to monitor the daylighting performance of different glazing

258

High Performance Commercial Building Systems William L. Carroll  

E-Print Network [OSTI]

Efficiency and Renewable Energy, Building Technologies Program of the U.S. Department of Energy underHigh Performance Commercial Building Systems William L. Carroll Ernest Orlando Lawrence Berkeley.2 ­ Retrofit Tools Task 2 HPBCS E2P2.2T3 LBNL - 57775 California Energy Commission Public Interest Energy

259

Image Recognition System for Automated Lighting Retrofit Assessment  

E-Print Network [OSTI]

, and K. Baugh, ?Spectral Identification of Lighting Type and Character,? Sensors, vol. 10, pp. 3961-3988, 2010. (3) L. Halonen, E. Tetri, and P. Bhusal, ?Guidebook on Energy Efficient Electric Lighting for Buildings,? Espoo, Finland: Dept. Elect. Eng...

Venable, K.; Bhatia, D.; Coverick, R.; Gutierrez, C.; Knight, J.; McGarry, D.; McGee, K.; Smith, Z.; Terrill, T. J.; Vanderford, B.; Weiser, R.; Wightman, K.; Rasmussen, B. P.

2013-01-01T23:59:59.000Z

260

FEMP Presents Its Newest On-Demand eTraining Course on Building Automation  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector General Office of Audit|Department ofof Energy Offers Training on the Five Phases toSystems |

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Optimal Control of Building HVAC Systems in the Presence of Imperfect Predictions, ASME Dynamic System Control Conference  

E-Print Network [OSTI]

optimal control design for HVAC systems,” in Dynamic Systemalgorithm design for hvac systems in energy efficient build-OPTIMAL CONTROL OF BUILDING HVAC SYSTEMS IN THE PRESENCE OF

Maasoumy, Mehdi

2012-01-01T23:59:59.000Z

262

Precursor systems analyses of automated highway systems. Activity area C. Automated check-out. Final report, September 1993-November 1994  

SciTech Connect (OSTI)

The activity evaluates potential automatic-to-manual transition scenarios in terms of relative feasibility, safety, cost, and social implications. The check-out alternatives range from minimal testing of the operator and the vehicle to extensive testing of the operator and vehicle. The vehicle functions analysis presents a summary of functions that are critical to safe manual operation and proposes several options for validation. Two possible check-out processes are discussed, one intended for AHS lanes dedicated to automated traffic, and one intended for mixed mode lanes in which AHS and non-AHS vehicles are traveling. The transition to manual control will involve preparing the driver to resume manual operation prior to release of vehicle functions. Proposed tasks which could be used to determine that the driver is ready to receive control of the automated vehicle are examined.

Mangarelli, F.; Cochran, A.; Craig, D.; Michael, B.; Halseth, M.

1995-05-01T23:59:59.000Z

263

AUTOMATING THE SELECTION OF FENESTRATION SYSTEMS TO BEST MEET DAYLIGHTING PERFORMANCE GOALS  

E-Print Network [OSTI]

AUTOMATING THE SELECTION OF FENESTRATION SYSTEMS TO BEST MEET DAYLIGHTING PERFORMANCE GOALS Luís closer to producing the desired flux distribution from the outdoor daylight distribution. INTRODUCTION The selection of fenestration systems for daylighting is traditionally done by trial and error. Designers try

264

Automated Analysis of Fault-Tolerance in Distributed Systems Scott D. Stoller y  

E-Print Network [OSTI]

Automated Analysis of Fault-Tolerance in Distributed Systems #3; Scott D. Stoller y Computer satisfy in speci#12;ed failure scenarios. Our analysis method is to compute, for each failure scenario for which the user speci#12;ed a fault-tolerance requirement, an MFG representing the system's communication

Schneider, Fred B.

265

Using Explicit and Machine-Understandable Engineering Knowledge for Defect Detection in Automation Systems Engineering  

E-Print Network [OSTI]

Systems Engineering Olga Kovalenko and Thomas Moser Christian Doppler Laboratory for Software Engineering automation systems, e.g. mechanical engineering, electrical engineering and software engineering. Experts of efforts from different types of experts, e.g. software engineers, technical engineers and domain experts

266

World Automation Congress 2010 TSI Press. USING A FUZZY LOGIC CONTROL SYSTEM FOR AN XPILOT  

E-Print Network [OSTI]

World Automation Congress © 2010 TSI Press. USING A FUZZY LOGIC CONTROL SYSTEM FOR AN XPILOT COMBAT {ahubley, parker}@conncoll.edu ABSTRACT--Fuzzy logic controllers provide a means of reasoning in uncertain systems. In this paper, we use fuzzy logic to develop a more versatile controller that can deal

Parker, Gary B.

267

Operation Diagnosis for Buildings Connecting Building Management Systems with Energy Management Systems  

E-Print Network [OSTI]

Reducing energy consumption of buildings is a good contribution to protect the environment and to reduce costs. The first and most important step to operate a building most efficiently is to make aware of most of the technical parameters. Connecting...

Mehler, G.

2008-01-01T23:59:59.000Z

268

The systems approach to building : a study of systems building development  

E-Print Network [OSTI]

The new demand for building and the problems generated by this demand confronting the building industry have become more complex as a result of increasing social change, evolution of industrialization and inadequacy of ...

Sittipunt, Preechaya

1984-01-01T23:59:59.000Z

269

A normative approach to the evaluation of industrialized building systems  

E-Print Network [OSTI]

The rapid development of the building industry within the last 10-15 years involved the adaptation of a more. specialized and advanced system of construction and management. And, with the expanding alternatives of ...

Alhasani, Nadia Mehdi

1984-01-01T23:59:59.000Z

270

Building America Webinar: Central Multifamily Water Heating Systems  

Broader source: Energy.gov [DOE]

Hosted by DOE's Building America program, this webinar will focus on the effective use of central heat pump water heaters (HPWHs) and control systems to reduce the energy use in hot water distribution.

271

TRANSPORTATION SYSTEMS are the build-ing blocks of modern society. Efficient and  

E-Print Network [OSTI]

TRANSPORTATION SYSTEMS are the build- ing blocks of modern society. Efficient and safe movement. How- ever, transportation systems by their very nature also affect the environment through operations, construction, and maintenance of transportation facilities, and through the travel behaviors they encourage

Storici, Francesca

272

System and method for pre-cooling of buildings  

DOE Patents [OSTI]

A method for nighttime pre-cooling of a building comprising inputting one or more user settings, lowering the indoor temperature reading of the building during nighttime by operating an outside air ventilation system followed, if necessary, by a vapor compression cooling system. The method provides for nighttime pre-cooling of a building that maintains indoor temperatures within a comfort range based on the user input settings, calculated operational settings, and predictions of indoor and outdoor temperature trends for a future period of time such as the next day.

Springer, David A.; Rainer, Leo I.

2011-08-09T23:59:59.000Z

273

Recent Developments of the Modelica"Buildings" Library for Building Energy and Control Systems  

SciTech Connect (OSTI)

At the Modelica 2009 conference, we introduced the Buildings library, a freely available Modelica library for building energy and control systems. This paper reports the updates of the library and presents example applications for a range of heating, ventilation and air conditioning (HVAC) systems. Over the past two years, the library has been further developed. The number of HVAC components models has been doubled and various components have been revised to increase numerical robustness.The paper starts with an overview of the library architecture and a description of the main packages. To demonstrate the features of the Buildings library, applications that include multizone airflow simulation as well as supervisory and local loop control of a variable air volume (VAV) system are briefly described. The paper closes with a discussion of the current development.

Wetter, Michael; Zuo, Wangda; Nouidui, Thierry Stephane

2011-04-01T23:59:59.000Z

274

Modeling the Energy Use of a Connected and Automated Transportation System (Poster)  

SciTech Connect (OSTI)

Early research points to large potential impacts of connected and automated vehicles (CAVs) on transportation energy use - dramatic savings, increased use, or anything in between. Due to a lack of suitable data and integrated modeling tools to explore these complex future systems, analyses to date have relied on simple combinations of isolated effects. This poster proposes a framework for modeling the potential energy implications from increasing penetration of CAV technologies and for assessing technology and policy options to steer them toward favorable energy outcomes. Current CAV modeling challenges include estimating behavior change, understanding potential vehicle-to-vehicle interactions, and assessing traffic flow and vehicle use under different automation scenarios. To bridge these gaps and develop a picture of potential future automated systems, NREL is integrating existing modeling capabilities with additional tools and data inputs to create a more fully integrated CAV assessment toolkit.

Gonder, J.; Brown, A.

2014-07-01T23:59:59.000Z

275

Building a Smarter Distribution System in Pennsylvania  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:YearRound-Up fromDepartmentTie Ltd:June 2015 < prev nextInvestigationofBuildingTomorrow'saa

276

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings  

E-Print Network [OSTI]

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings Tom Rogg REU Student to assist HVAC has the potential to significantly reduce life cycle cost and energy consumption and electrical system that will tie thermostats to controlled valves in the actual HVAC system. Based on results

Mountziaris, T. J.

277

Automated Measurement and Signaling Systems for the Transactional Network  

SciTech Connect (OSTI)

The Transactional Network Project is a multi-lab activity funded by the US Department of Energy?s Building Technologies Office. The project team included staff from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory and Oak Ridge National Laboratory. The team designed, prototyped and tested a transactional network (TN) platform to support energy, operational and financial transactions between any networked entities (equipment, organizations, buildings, grid, etc.). PNNL was responsible for the development of the TN platform, with agents for this platform developed by each of the three labs. LBNL contributed applications to measure the whole-building electric load response to various changes in building operations, particularly energy efficiency improvements and demand response events. We also provide a demand response signaling agent and an agent for cost savings analysis. LBNL and PNNL demonstrated actual transactions between packaged rooftop units and the electric grid using the platform and selected agents. This document describes the agents and applications developed by the LBNL team, and associated tests of the applications.

Piette, Mary Ann; Brown, Richard; Price, Phillip; Page, Janie; Granderson, Jessica; Riess, David; Czarnecki, Stephen; Ghatikar, Girish; Lanzisera, Steven

2013-12-31T23:59:59.000Z

278

Development and evaluation of an automated reflectance microscope system for the petrographic characterization of bituminous coals  

SciTech Connect (OSTI)

The development of automated coal petrographic techniques will lessen the demands on skilled personnel to do routine work. This project is concerned with the development and successful testing of an instrument which will meet these needs. The fundamental differences in reflectance of the three primary maceral groups should enable their differentiation in an automated-reflectance frequency histogram (reflectogram). Consequently, reflected light photometry was chosen as the method for automating coal petrographic analysis. Three generations of an automated system (called Rapid Scan Versions I, II and III) were developed and evaluated for petrographic analysis. Their basic design was that of a reflected-light microscope photometer with an automatic stage, interfaced with a minicomputer. The hardware elements used in the Rapid Scan Version I limited the system's flexibility and presented problems with signal digitization and measurement precision. Rapid Scan Version II was designed to incorporate a new microscope photometer and computer system. A digital stepping stage was incorporated into the Rapid Scan Version III system. The precision of reflectance determination of this system was found to be +- 0.02 percent reflectance. The limiting factor in quantitative interpretation of Rapid Scan reflectograms is the resolution of reflectance populations of the individual maceral groups. Statistical testing indicated that reflectograms were highly reproducible, and a new computer program, PETAN, was written to interpret the curves for vitrinite reflectance parameters ad petrographic.

Hoover, D. S.; Davis, A.

1980-10-01T23:59:59.000Z

279

Automated Demand Response and Commissioning  

SciTech Connect (OSTI)

This paper describes the results from the second season of research to develop and evaluate the performance of new Automated Demand Response (Auto-DR) hardware and software technology in large facilities. Demand Response (DR) is a set of activities to reduce or shift electricity use to improve the electric grid reliability and manage electricity costs. Fully-Automated Demand Response does not involve human intervention, but is initiated at a home, building, or facility through receipt of an external communications signal. We refer to this as Auto-DR. The evaluation of the control and communications must be properly configured and pass through a set of test stages: Readiness, Approval, Price Client/Price Server Communication, Internet Gateway/Internet Relay Communication, Control of Equipment, and DR Shed Effectiveness. New commissioning tests are needed for such systems to improve connecting demand responsive building systems to the electric grid demand response systems.

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Bourassa, Norman

2005-04-01T23:59:59.000Z

280

Open Automated Demand Response Technologies for Dynamic Pricing and Smart Grid  

E-Print Network [OSTI]

for Automated Demand Response in Commercial Buildings. ” In2010. “Open Automated Demand Response Dynamic Pricing2009. “Open Automated Demand Response Communications

Ghatikar, Girish

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Demonstration of Datacenter Automation Software and Hardware (DASH) at the California Franchise Tax Board  

E-Print Network [OSTI]

of Datacenter Automation Software and Hardware (DASH) at theof Datacenter Automation Software and Hardware (DASH) at theprotocol for building automation and control networks. It is

Bell, Geoffrey C.

2010-01-01T23:59:59.000Z

282

System design and dynamic signature identification for intelligent energy management in residential buildings.  

E-Print Network [OSTI]

Drewer and D. Gann, Smart buildings, Journal of Facilities ,smart energy management system specically for residential buildings.buildings is rooted in relative eectiveness per system by a smart

Jang, Jaehwi

2008-01-01T23:59:59.000Z

283

Development of a Model Specification for Performance Monitoring Systems for Commercial Buildings  

E-Print Network [OSTI]

Development of a Model Specification for Performance Monitoring Systems for Commercial Buildings the development of a model specification for performance monitoring systems for commercial buildings capabilities in #12;commercial buildings by demonstrating the capabilities of commercially available technology

284

Manual of Security Requirements for the Classified Automated Information System Security Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Manual provides specific instructions and delineates the requirements to ensure the graded security of classified information entrusted to the Department of Energy (DOE) that is processed, stored, transferred, or accessed on Automated Information Systems (AISs) and AIS networks. Canceled by DOE M 471.2-2.

1994-07-15T23:59:59.000Z

285

Simulation And Visualization Of Automated Guided Vehicle Systems In A Real Production Environment  

E-Print Network [OSTI]

Low-cost Automated Guided Vehicle Systems (AGVS) play an increasing role for the automation of production plants. For complex installations, a simulation of the transport system should be performed during the planning phase in order to check for possible problems and to optimize parameters. During operation of complex AGVS a visualization of the whole system is desirable in order to allow a continuous monitoring. Since most of the relevant tasks have to be performed for simulation and visualization as well, we constructed an integrated tool which is able to deal with both jobs. As an example for operation of the simulation tool, results are presented for the calculation of the number of vehicles for optimal performance of an AGVS given a layout and a transport matrix. OVERVIEW As mentioned above, low-cost Automated Guided Vehicle Systems (AGVS) play an increasing role for the automation of production plants since they can be used as a flexible assembly line (Muller 1993). In recent yea...

Axel Hoff; Holger Vogelsang; Uwe Brinkschulte; Oliver Hammerschmidt

1997-01-01T23:59:59.000Z

286

Automated Energy Distribution and Reliability System: Validation Integration - Results of Future Architecture Implementation  

SciTech Connect (OSTI)

This report describes Northern Indiana Public Service Co. project efforts to develop an automated energy distribution and reliability system. The purpose of this project was to implement a database-driven GIS solution that would manage all of the company's gas, electric, and landbase objects. This report is second in a series of reports detailing this effort.

Buche, D. L.

2008-06-01T23:59:59.000Z

287

DEVELOPMENT OF AN ULTRASONIC NDT SYSTEM FOR AUTOMATED IN-SITU INSPECTION OF WIND TURBINE BLADES  

E-Print Network [OSTI]

DEVELOPMENT OF AN ULTRASONIC NDT SYSTEM FOR AUTOMATED IN- SITU INSPECTION OF WIND TURBINE BLADES Abington, Cambridge, CB21 6AL, UK bic@brunel.ac.uk ABSTRACT It is crucial to maintain wind turbine blades. This work investigates using pulse-echo ultrasound to detect internal damages in wind turbine blades without

Boyer, Edmond

288

Deadlock Avoidance Policies for Automated Manufacturing Systems Using Finite State Automata  

E-Print Network [OSTI]

Automata Spyros Reveliotis and Ahmed Nazeem1 1S. Reveliotis is with the School of Industrial & Systems product lines and more customized product offerings [22]. Indeed, since the beginning of the industrial revolution, automation has been at the core of the mass-production concept and practices, enabling activities

Reveliotis, Spiridon "Spyros"

289

Validating Predicted Rural Corridor Travel Times from an Automated License Plate Recognition System: Oregon's Frontier Project  

E-Print Network [OSTI]

: Oregon's Frontier Project Robert L. Bertini Department of Civil & Environmental Engineering Portland of a corridor travel time prediction system that uses automated license plate recognition­the Frontier Travel Time project. As part of the Frontier project, the Oregon Department of Transportation deployed a video

Bertini, Robert L.

290

A Fully Automated Fault-tolerant System for Distributed Video Processing and Off-site Replication  

E-Print Network [OSTI]

A Fully Automated Fault-tolerant System for Distributed Video Processing and Off-site Replication been a failure-prone tedious operation with an operator needed to babysit the processing and off-site, off-site replication, fault-tolerance, grid, educational research. 1. INTRODUCTION In different fields

Wisconsin at Madison, University of

291

High-performance commercial building systems  

E-Print Network [OSTI]

Cooling system efficiency can be improved through the appropriate use of compressor-less cooling technologies and techniquesCooling system efficiency can be improved through the appropriate use of compressor-less cooling technologies and techniques

Selkowitz, Stephen

2003-01-01T23:59:59.000Z

292

A Buildings Module for the Stochastic Energy Deployment System  

SciTech Connect (OSTI)

The U.S. Department of Energy (USDOE) is building a new long-range (to 2050) forecasting model for use in budgetary and management applications called the Stochastic Energy Deployment System (SEDS), which explicitly incorporates uncertainty through its development within the Analytica(R) platform of Lumina Decision Systems. SEDS is designed to be a fast running (a few minutes), user-friendly model that analysts can readily run and modify in its entirety through a visual programming interface. Lawrence Berkeley National Laboratory is responsible for implementing the SEDS Buildings Module. The initial Lite version of the module is complete and integrated with a shared code library for modeling demand-side technology choice developed by the National Renewable Energy Laboratory (NREL) and Lumina. The module covers both commercial and residential buildings at the U.S. national level using an econometric forecast of floorspace requirement and a model of building stock turnover as the basis for forecasting overall demand for building services. Although the module is fundamentally an engineering-economic model with technology adoption decisions based on cost and energy performance characteristics of competing technologies, it differs from standard energy forecasting models by including considerations of passive building systems, interactions between technologies (such as internal heat gains), and on-site power generation.

Lacommare, Kristina S H; Marnay, Chris; Stadler, Michael; Borgeson, Sam; Coffey, Brian; Komiyama, Ryoichi; Lai, Judy

2008-05-15T23:59:59.000Z

293

Results and commissioning issues from an automated demand response pilot  

E-Print Network [OSTI]

Management and Demand Response in Commercial Buildings", L BAutomated Demand Response National Conference on BuildingAutomated Demand Response National Conference on Building

Piette, Mary Ann; Watson, Dave; Sezgen, Osman; Motegi, Naoya

2004-01-01T23:59:59.000Z

294

Scenarios for Consuming Standardized Automated Demand Response Signals  

E-Print Network [OSTI]

Keywords: Demand response, automation, commercial buildings,Demand Response and Energy Efficiency in Commercial Buildings,Building Control Strategies and Techniques for Demand Response.

Koch, Ed

2009-01-01T23:59:59.000Z

295

Automated Critical Peak Pricing Field Tests: Program Description and Results  

E-Print Network [OSTI]

is manual demand response -- where building staff receive afor demand response analysis ?ELECTRIC Whole building powerof automated demand response (Auto-DR) in buildings and

Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Xu, Peng

2006-01-01T23:59:59.000Z

296

Open Automated Demand Response Dynamic Pricing Technologies and Demonstration  

E-Print Network [OSTI]

for Automated Demand Response in Commercial Buildings. Inbased demand response information to building controlDemand Response Standard for the Residential Sector. California Energy Commission, PIER Buildings

Ghatikar, Girish

2010-01-01T23:59:59.000Z

297

Direct versus Facility Centric Load Control for Automated Demand Response  

E-Print Network [OSTI]

Keywords: Demand response, automation, commercial buildings,Demand Response and Energy Efficiency in Commercial Buildings,Building Control Strategies and Techniques for Demand Response.

Piette, Mary Ann

2010-01-01T23:59:59.000Z

298

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network [OSTI]

LBNL-6432E Comparison of Building Energy Modeling Programs: HVAC Systems Xin Zhou1 , Tianzhen Hong2 programs (BEMPs) for HVAC calculations: EnergyPlus, DeST, and DOE-2.1E. This is a joint effort between purposes, BEMPs can be divided into load modules and HVAC system modules. This technical report

299

Building a Smarter Distribution System in Pennsylvania  

Broader source: Energy.gov (indexed) [DOE]

Development of an advanced distribution management system (DMS) software is at the heart of the project. The DMS monitors and controls all of the smart devices being installed...

300

Automated Demand Response and Commissioning  

E-Print Network [OSTI]

Fully-Automated Demand Response Test in Large Facilities14in DR systems. Demand Response using HVAC in Commercialof Fully Automated Demand Response in Large Facilities”

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Bourassa, Norman

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Energy-Efficient Building HVAC Control Using Hybrid System LBMPC  

E-Print Network [OSTI]

Improving the energy-efficiency of heating, ventilation, and air-conditioning (HVAC) systems has the potential to realize large economic and societal benefits. This paper concerns the system identification of a hybrid system model of a building-wide HVAC system and its subsequent control using a hybrid system formulation of learning-based model predictive control (LBMPC). Here, the learning refers to model updates to the hybrid system model that incorporate the heating effects due to occupancy, solar effects, outside air temperature (OAT), and equipment, in addition to integrator dynamics inherently present in low-level control. Though we make significant modeling simplifications, our corresponding controller that uses this model is able to experimentally achieve a large reduction in energy usage without any degradations in occupant comfort. It is in this way that we justify the modeling simplifications that we have made. We conclude by presenting results from experiments on our building HVAC testbed, which s...

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

302

Co-Simulation of Building Energy and Control Systems with the Building Controls Virtual Test Bed  

SciTech Connect (OSTI)

This article describes the implementation of the Building Controls Virtual Test Bed (BCVTB). The BCVTB is a software environment that allows connecting different simulation programs to exchange data during the time integration, and that allows conducting hardware in the loop simulation. The software architecture is a modular design based on Ptolemy II, a software environment for design and analysis of heterogeneous systems. Ptolemy II provides a graphical model building environment, synchronizes the exchanged data and visualizes the system evolution during run-time. The BCVTB provides additions to Ptolemy II that allow the run-time coupling of different simulation programs for data exchange, including EnergyPlus, MATLAB, Simulink and the Modelica modelling and simulation environment Dymola. The additions also allow executing system commands, such as a script that executes a Radiance simulation. In this article, the software architecture is presented and the mathematical model used to implement the co-simulation is discussed. The simulation program interface that the BCVTB provides is explained. The article concludes by presenting applications in which different state of the art simulation programs are linked for run-time data exchange. This link allows the use of the simulation program that is best suited for the particular problem to model building heat transfer, HVAC system dynamics and control algorithms, and to compute a solution to the coupled problem using co-simulation.

Wetter, Michael

2010-08-22T23:59:59.000Z

303

A toolkit for building earth system models  

SciTech Connect (OSTI)

An earth system model is a computer code designed to simulate the interrelated processes that determine the earth`s weather and climate, such as atmospheric circulation, atmospheric physics, atmospheric chemistry, oceanic circulation, and biosphere. I propose a toolkit that would support a modular, or object-oriented, approach to the implementation of such models.

Foster, I.

1993-03-01T23:59:59.000Z

304

A toolkit for building earth system models  

SciTech Connect (OSTI)

An earth system model is a computer code designed to simulate the interrelated processes that determine the earth's weather and climate, such as atmospheric circulation, atmospheric physics, atmospheric chemistry, oceanic circulation, and biosphere. I propose a toolkit that would support a modular, or object-oriented, approach to the implementation of such models.

Foster, I.

1993-03-01T23:59:59.000Z

305

Lateral Control of Heavy Vehicles for Automated Systems  

E-Print Network [OSTI]

system tracks the desired front wheel steering angle (? 1 ) exactly, then the sliding variable will asymptotically converg to a ball,

Hingwe, Pushkar; Wang, Jen-Yu; Tai, Meihua; Tomizuka, Masayoshi

2003-01-01T23:59:59.000Z

306

Functional requirements for the Automated Transportation Management System: TTP number: RL 439002  

SciTech Connect (OSTI)

This requirements analysis, documents Department of Energy (DOE) transportation management procedures for the purpose of providing a clear and mutual understanding between users and designers of the proposed Automated Transportation Management System (ATMS). It is imperative that one understand precisely how DOE currently performs traffic management tasks; only then can an integrated system be proposed that successfully satisfies the major requirements of transportation managers and other system users. Accordingly, this report describes the current workings of DOE transportation organizations and then proposes a new system which represents a synthesis of procedures (both current and desired) which forms the basis for further systems development activities.

Portsmouth, J.H. [Westinghouse Hanford Co., Richland, WA (United States)

1992-12-31T23:59:59.000Z

307

A Prototype Data Archive for the PIER "Thermal Distribution Systems in Commercial Buildings" Project  

E-Print Network [OSTI]

A Prototype Data Archive for the PIER "Thermal Distribution Systems in Commercial Buildings archive for a selection of building energy data on thermal distribution systems in commercial buildings and Purpose The PIER "Thermal Distribution Systems in Commercial Buildings" (TDSCB) project (Diamond et al

308

Results and commissioning issues from an automated demand response pilot  

E-Print Network [OSTI]

of Fully Automated Demand Response in Large Facilities"Management and Demand Response in Commercial Buildings", L Band Commissioning Issues from an Automated Demand Response.

Piette, Mary Ann; Watson, Dave; Sezgen, Osman; Motegi, Naoya

2004-01-01T23:59:59.000Z

309

Justification to remove 333 Building fire suppression system  

SciTech Connect (OSTI)

Justification to remove the 333 Building fire suppression system is provided. The Maximum Possible Fire Loss (MPFL) is provided (approximately $800K), potential radiological and toxicological impacts from a postulated fire are discussed, Life Safety Code issues are addressed, and coordination with the Hanford Fire Department is assured.

Benecke, M.W.

1995-12-04T23:59:59.000Z

310

HVAC & Building Management Control System Energy Efficiency Replacements  

SciTech Connect (OSTI)

The project objective was the replacement of an aging, un-repairable HVAC system which has grown inefficient and a huge energy consumer with low energy and efficient HVAC units, and installation of energy efficient building control technologies at City's YMCA Community Center.

Hernandez, Adriana

2012-09-21T23:59:59.000Z

311

Architectural Building Blocks for Plug-and-Play System Design  

E-Print Network [OSTI]

Architectural Building Blocks for Plug-and-Play System Design Shangzhu Wang, George S. Avrunin semantics. Our approach is also integrated with design-time verification to provide feedback about with each other. Given the com- plexity of the behavior that is being described and the large design space

Avrunin, George S.

312

Integrated Energy Systems (IES) for Buildings: A Market Assessment  

SciTech Connect (OSTI)

Integrated Energy Systems (IES) combine on-site power or distributed generation technologies with thermally activated technologies to provide cooling, heating, humidity control, energy storage and/or other process functions using thermal energy normally wasted in the production of electricity/power. IES produce electricity and byproduct thermal energy onsite, with the potential of converting 80 percent or more of the fuel into useable energy. IES have the potential to offer the nation the benefits of unprecedented energy efficiency gains, consumer choice and energy security. It may also dramatically reduce industrial and commercial building sector carbon and air pollutant emissions and increase source energy efficiency. Applications of distributed energy and Combined heat and power (CHP) in ''Commercial and Institutional Buildings'' have, however, been historically limited due to insufficient use of byproduct thermal energy, particularly during summer months when heating is at a minimum. In recent years, custom engineered systems have evolved incorporating potentially high-value services from Thermally Activated Technologies (TAT) like cooling and humidity control. Such TAT equipment can be integrated into a CHP system to utilize the byproduct heat output effectively to provide absorption cooling or desiccant humidity control for the building during these summer months. IES can therefore expand the potential thermal energy services and thereby extend the conventional CHP market into building sector applications that could not be economically served by CHP alone. Now more than ever, these combined cooling, heating and humidity control systems (IES) can potentially decrease carbon and air pollutant emissions, while improving source energy efficiency in the buildings sector. Even with these improvements over conventional CHP systems, IES face significant technological and economic hurdles. Of crucial importance to the success of IES is the ability to treat the heating, ventilation, air conditioning, water heating, lighting, and power systems loads as parts of an integrated system, serving the majority of these loads either directly or indirectly from the CHP output. The CHP Technology Roadmaps (Buildings and Industry) have focused research and development on a comprehensive integration approach: component integration, equipment integration, packaged and modular system development, system integration with the grid, and system integration with building and process loads. This marked change in technology research and development has led to the creation of a new acronym to better reflect the nature of development in this important area of energy efficiency: Integrated Energy Systems (IES). Throughout this report, the terms ''CHP'' and ''IES'' will sometimes be used interchangeably, with CHP generally reserved for the electricity and heat generating technology subsystem portion of an IES. The focus of this study is to examine the potential for IES in buildings when the system perspective is taken, and the IES is employed as a dynamic system, not just as conventional CHP. This effort is designed to determine market potential by analyzing IES performance on an hour-by-hour basis, examining the full range of building types, their loads and timing, and assessing how these loads can be technically and economically met by IES.

LeMar, P.

2002-10-29T23:59:59.000Z

313

The Canadian Automated Meteor Observatory (CAMO): System overview R.J. Weryk a,  

E-Print Network [OSTI]

The Canadian Automated Meteor Observatory (CAMO): System overview R.J. Weryk a, , M.D. Campbell-Brown a,b , P.A. Wiegert a,b , P.G. Brown a,b , Z. Krzeminski a , R. Musci a a Dept. of Physics and Brown, 2012, 2013) using the Canadian Meteor Orbit Radar (CMOR) and a number of Gen-III image

Wiegert, Paul

314

Algorithms and Automated Material Handling Systems Design for Stacking 3D Irregular Stone Pieces  

E-Print Network [OSTI]

ALGORITHMS AND AUTOMATED MATERIAL HANDLING SYSTEMS DESIGN FOR STACKING 3D IRREGULAR STONE PIECES A Thesis by MING-CHENG KO Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment... Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements for the degree of MASTER OF SCIENCE Approved by: Chair of Committee, Sheng-Jen (?Tony?) Hsieh Committee Members, Sai C...

Ko, Ming-Cheng

2011-10-21T23:59:59.000Z

315

Automation and Accountability in Decision Support System Interface Design  

E-Print Network [OSTI]

When the human element is introduced into decision support system design, entirely new layers of social and ethical issues emerge but are not always recognized as such. This paper discusses those ethical and social impact ...

Cummings, M. L.

2006-01-01T23:59:59.000Z

316

Kinetic modeling and automated optimization in microreactor systems  

E-Print Network [OSTI]

The optimization, kinetic investigation, or scale-up of a reaction often requires significant time and materials. Silicon microreactor systems have been shown advantageous for studying chemical reactions due to their small ...

Moore, Jason Stuart

2013-01-01T23:59:59.000Z

317

LOW-COST BACTERIAL DETECTION SYSTEM FOR FOOD SAFETY BASED ON AUTOMATED DNA EXTRACTION, AMPLIFICATION AND READOUT  

E-Print Network [OSTI]

To ensure food, medical and environmental safety and quality, rapid, low-cost and easy-to-use detection methods are desirable. Here, the LabSystem is introduced for integrated, automated DNA purification and amplification. ...

Hoehl, Melanie Margarete

318

Efficient Detection on Stochastic Faults in PLC Based Automated Assembly Systems With Novel Sensor Deployment and Diagnoser Design  

E-Print Network [OSTI]

In this dissertation, we proposed solutions on novel sensor deployment and diagnoser design to efficiently detect stochastic faults in PLC based automated systems First, a fuzzy quantitative graph based sensor deployment was called upon to model...

Wu, Zhenhua

2012-07-16T23:59:59.000Z

319

Co-simulation of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

Canada: International Building Perfor- mance SimulationExternal coupling between building energy simulation andexternal coupling of building energy and air ow modeling

Trcka, Marija

2010-01-01T23:59:59.000Z

320

Build, Own, Operate and Maintain (BOOM) Boiler Systems  

E-Print Network [OSTI]

Build, Own, Operate and Maintain (BOOM) Boiler Systems Tom Henry, Annstrong Service, Inc. Overview: The article addresses the growing trend in outsourcing boiler equipment, installation, operation, maintenance and ownership by large.... In most cases, thennal, electric and air energy systems are not considered "core" assets resulting in the need to find "other" solutions to providing the needed energy. ? Reduced staffing has resulted in fewer experienced and knowledgeable boiler...

Henry, T.

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Energy Signal Tool for Decision Support in Building Energy Systems  

SciTech Connect (OSTI)

A prototype energy signal tool is demonstrated for operational whole-building and system-level energy use evaluation. The purpose of the tool is to give a summary of building energy use which allows a building operator to quickly distinguish normal and abnormal energy use. Toward that end, energy use status is displayed as a traffic light, which is a visual metaphor for energy use that is either substantially different from expected (red and yellow lights) or approximately the same as expected (green light). Which light to display for a given energy end use is determined by comparing expected to actual energy use. As expected, energy use is necessarily uncertain; we cannot choose the appropriate light with certainty. Instead, the energy signal tool chooses the light by minimizing the expected cost of displaying the wrong light. The expected energy use is represented by a probability distribution. Energy use is modeled by a low-order lumped parameter model. Uncertainty in energy use is quantified by a Monte Carlo exploration of the influence of model parameters on energy use. Distributions over model parameters are updated over time via Bayes' theorem. The simulation study was devised to assess whole-building energy signal accuracy in the presence of uncertainty and faults at the submetered level, which may lead to tradeoffs at the whole-building level that are not detectable without submetering.

Henze, G. P.; Pavlak, G. S.; Florita, A. R.; Dodier, R. H.; Hirsch, A. I.

2014-12-01T23:59:59.000Z

322

Automated Grid Disruption Response System: Robust Adaptive Topology Control (RATC)  

SciTech Connect (OSTI)

GENI Project: The RATC research team is using topology control as a mechanism to improve system operations and manage disruptions within the electric grid. The grid is subject to interruption from cascading faults caused by extreme operating conditions, malicious external attacks, and intermittent electricity generation from renewable energy sources. The RATC system is capable of detecting, classifying, and responding to grid disturbances by reconfiguring the grid in order to maintain economically efficient operations while guaranteeing reliability. The RATC system would help prevent future power outages, which account for roughly $80 billion in losses for businesses and consumers each year. Minimizing the time it takes for the grid to respond to expensive interruptions will also make it easier to integrate intermittent renewable energy sources into the grid.

None

2012-03-01T23:59:59.000Z

323

The Freight Shuttle System: Automated-Secure Trade  

E-Print Network [OSTI]

the same volume) #12;HDD Truck vs. FSS (CO2 required to service the same volume) #12;Next Steps · Finalize footprint guide way ­ To be built within existing highway ROW The Freight Shuttle System 24/7 operations transportation #12;#12;#12;#12;Port of Entry Security #12;Ciudad Juarez El Paso Scan-in-motion Scan

324

Development, Operation, and Results From the Texas Automated Buoy System  

E-Print Network [OSTI]

of the Gulf of Mexico Coastal Ocean Observing System (GCOOS) regional association and the primary source of near-surface current measurements in the northwestern Gulf of Mexico. This article describes the origin of Angolan crude, exploded and caught fire while lightering its cargo about 60 nautical miles south

325

One IBM Plant's Approach to Automated Control System Standards  

E-Print Network [OSTI]

of operation. All instrumentation symbols and identification used in our standards are from the Instrument Society of America Standard ISA-S5.1. Description of Operation - Each type of HVAC system to be used and operated has a com plete descriptive...

Cilia, J. P.

326

Advanced Retro-commissioning Technology: Predictive Energy Optimization (PEO) and Automated Demand Response for Commercial Building HVAC  

Broader source: Energy.gov [DOE]

Lead Performer: BuildingIQ, Inc. – Foster City, CaliforniaPartners: Department of General Services – Washington, DCDOE Funding: $1,767,138Cost Share: $1,767,138Project Term: October 2014 –...

327

Performance of Integrated Systems of Automated Roller Shade Systems and Daylight Responsive Dimming Systems  

E-Print Network [OSTI]

Roller Shade Systems and Daylight Responsive Dimming SystemsRoller Shade Systems and Daylight Responsive Dimming SystemsBerkeley, CA 94720 Abstract Daylight responsive dimming

Park, Byoung-Chul

2011-01-01T23:59:59.000Z

328

First workshop on the Building System Integration Laboratory  

SciTech Connect (OSTI)

The Whole Building Systems Integration Laboratory (WBSIL) feasibility study was initiated by the US Department of Energy (DOE) to determine the feasibility of constructing a laboratory dedicated to the investigation of whole-building system-integration issues. The Pacific Northwest Laboratory (PNL) is conducting this study. To ensure the feasibility study receives a wide range of input, an advisory committee has been formed to assist in establishing the functional criteria for the WBSIL. The advisory committee consists of nationally recognized experts in a variety of disciplines related to building research, design and operation. The original plan was for the advisory committee to provide guidance for the study in three forms. First, the advisory committee was to complete a questionnaire on whole building research issues and products. This was to be followed by the first workshop where the advisory committee would provide information on the need for the WBSIL and on its required design features. Finally, the advisory committee was to meet a second time to provide a review of the conceptual design of the facility and the functional criteria.

Drost, M K; Johnson, B M; Crawley, D B

1989-09-01T23:59:59.000Z

329

Automated Surface Observing System: Standby Power Options | Department of  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EERE BlogAttachmentFlash2011-21 AuditInsulated Cladding Systems

330

Automated Transportation Management System (ATMS) | Department of Energy  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious Rank EERE:Year in Review: Top Five EERE BlogAttachmentFlash2011-21 AuditInsulated Cladding SystemsWaste

331

Tritium Irrigation Facility & Automated Vadose Zone Monitoring System |  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE:1 First Use of Energy for All Purposes (Fuel and Nonfuel),Feet) Year Jan Feb Mar Apr May Jun Jul(Summary)morphinanInformation Desert Southwest RegionatSearchScheduled System BurstLongTitanConsortium UniversitiesSavannah

332

A Data and Knowledge Management System for Intelligent Buildings  

E-Print Network [OSTI]

words: Intelligent building; Assessment; Methodology; Information system 1. INTRODUCTION It is the development and application of modern technologies in the areas of information, communication, materials, and machinery in the construction... of IBs, while facilities managers may hold operation information of IBs. In fact, it may take much effort to retrieve useful information for specified purposes such as IB assessment from various sources if there is not an information pervasive...

Hong, J.; Chen, Z.; Li, H.; Xu, Q.

2006-01-01T23:59:59.000Z

333

Technology Enablers for Next-Generation Economic Building Monitoring Systems  

E-Print Network [OSTI]

is essential to achieve a lower cost for building energy monitoring and analysis. The next-generation system discussed in this paper is a complete redesign. It will be Internet-enabled and secure; take advantage of current advances in smarter sensors, use... may only include sensors, and data collection and control subsystems. In order for these subsystems to interoperate, they must be networked with standard communication protocols. The Internet provides an open communication protocol, Transmission...

Sweeney, J., Jr.; Culp, C.

2001-01-01T23:59:59.000Z

334

FORTRAN M as a language for building earth system models  

SciTech Connect (OSTI)

FORTRAN M is a small set of extensions to FORTRAN 77 that supports a modular or object-oriented approach to the development of parallel programs. In this paper, I discuss the use of FORTRAN M as a tool for building earth system models on massively parallel computers. I hypothesize that the use of FORTRAN M has software engineering advantages and outline experiments that we are conducting to investigate this hypothesis.

Foster, I.

1992-01-01T23:59:59.000Z

335

FORTRAN M as a language for building earth system models  

SciTech Connect (OSTI)

FORTRAN M is a small set of extensions to FORTRAN 77 that supports a modular or object-oriented approach to the development of parallel programs. In this paper, I discuss the use of FORTRAN M as a tool for building earth system models on massively parallel computers. I hypothesize that the use of FORTRAN M has software engineering advantages and outline experiments that we are conducting to investigate this hypothesis.

Foster, I.

1992-12-31T23:59:59.000Z

336

Co-design of Control Algorithm and Embedded Platformfor Building HVAC Systems  

E-Print Network [OSTI]

algorithm design for hvac systems in energy efficientOptimal control of HVAC systems in the presence of imperfectminimization of building hvac systems using model predictive

Maasoumy, Mehdi; Zhu, Qi; Li, Cheng; Meggers, Forrest; Sangiovanni-Vincentelli, Alberto

2013-01-01T23:59:59.000Z

337

CARRIER PREPARATION BUILDING MATERIALS HANDLING SYSTEM DESCRIPTION DOCUMENT  

SciTech Connect (OSTI)

The Carrier Preparation Building Materials Handling System receives rail and truck shipping casks from the Carrier/Cask Transport System, and inspects and prepares the shipping casks for return to the Carrier/Cask Transport System. Carrier preparation operations for carriers/casks received at the surface repository include performing a radiation survey of the carrier and cask, removing/retracting the personnel barrier, measuring the cask temperature, removing/retracting the impact limiters, removing the cask tie-downs (if any), and installing the cask trunnions (if any). The shipping operations for carriers/casks leaving the surface repository include removing the cask trunnions (if any), installing the cask tie-downs (if any), installing the impact limiters, performing a radiation survey of the cask, and installing the personnel barrier. There are four parallel carrier/cask preparation lines installed in the Carrier Preparation Building with two preparation bays in each line, each of which can accommodate carrier/cask shipping and receiving. The lines are operated concurrently to handle the waste shipping throughputs and to allow system maintenance operations. One remotely operated overhead bridge crane and one remotely operated manipulator is provided for each pair of carrier/cask preparation lines servicing four preparation bays. Remotely operated support equipment includes a manipulator and tooling and fixtures for removing and installing personnel barriers, impact limiters, cask trunnions, and cask tie-downs. Remote handling equipment is designed to facilitate maintenance, dose reduction, and replacement of interchangeable components where appropriate. Semi-automatic, manual, and backup control methods support normal, abnormal, and recovery operations. Laydown areas and equipment are included as required for transportation system components (e.g., personnel barriers and impact limiters), fixtures, and tooling to support abnormal and recovery operations. The Carrier Preparation Building Materials Handling System interfaces with the Cask/Carrier Transport System to move the carriers to and from the system. The Carrier Preparation Building System houses the equipment and provides the facility, utility, safety, communications, and auxiliary systems supporting operations and protecting personnel.

E.F. Loros

2000-06-28T23:59:59.000Z

338

Investigation of shear lag effect in high-rise buildings with diagrid system  

E-Print Network [OSTI]

In the recent years, there have been many new skyscrapers built which soar into new heights. The most efficient building system for high-rises has been the framed tube system. However, the framed tube building suffers from ...

Leonard, Johan, M. Eng. Massachusetts Institute of Technology

2007-01-01T23:59:59.000Z

339

Systems, Advisory Systems and Safety Carles Sala Oliveras  

E-Print Network [OSTI]

Systems, Advisory Systems and Safety Carles Sala Oliveras Abstract Increasing the automation level of systems has led to more attention being paid to human control roles and the dependability of systems that comprise operators and machines. When humans build mental models of complex automated systems, they can

Newcastle upon Tyne, University of

340

Occupancy Based Fault Detection on Building Level - a Feasibility Study  

E-Print Network [OSTI]

-going commissioning and fault detection and diagnostics (FDD) has been performed to improve the current situation of building problems by comparing measured building performance with design predictions [Portland 2003]. For fault detection, different methods... conference on building commissioning, Portland Energy Conservation. Portland. 2003. Methods for automated and continuous commissioning of building systems. US department of commerce, Portland energy conservation inc. Schijndel, A.W.M. van, 2008...

Tuip, B.; Houten, M.; Trcka, M.; Hensen, M.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Demo Abstract: Building Energy Management Systems Actuated Using Wireless Camera Sensor Networks  

E-Print Network [OSTI]

Demo Abstract: Building Energy Management Systems Actuated Using Wireless Camera Sensor Networks for approximately 60% of the energy con- sumption within buildings [4]. The conditioning of these ar- eas, however, conditioning (HVAC) sys- tems in residential and commercial buildings account for 50% of the total building

Cerpa, Alberto E.

342

Development and Testing of an Information Monitoring and Diagnostics System for Large Commercial Buildings  

E-Print Network [OSTI]

A commercial office #12;buildings. Class A buildings are the most prestigious buildings in a particular marketDevelopment and Testing of an Information Monitoring and Diagnostics System for Large Commercial Buildings Mary Ann Piette , Lisa Gartland, Satkartar Khalsa, Lawrence Berkeley National Laboratory, Berkeley

343

Incorporating Life Cycle Assessment into the LEED Green Building Rating System  

E-Print Network [OSTI]

Incorporating Life Cycle Assessment into the LEED Green Building Rating System by Michael Supervisory Committee Incorporating Life Cycle Assessment into the LEED Green Building Rating System and regional product criteria within the LEED Green Building rating system are not based on comprehensive

Victoria, University of

344

Co-simulation for performance prediction of integrated building and HVAC systems -An analysis of solution  

E-Print Network [OSTI]

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis performance simulation of buildings and heating, ventilation and air- conditioning (HVAC) systems can help, heating, ventilation and air-conditioning (HVAC) systems are responsible for 10%-60% of the total building

345

LBNL# 40102 Field Investigation of Duct System Performance in California Light Commercial Buildings 1 of 26  

E-Print Network [OSTI]

LBNL# 40102 Field Investigation of Duct System Performance in California Light Commercial Buildings 1 of 26 Field Investigation of Duct System Performance in California Light Commercial Buildings Wm performance in fifteen systems located in eight northern California buildings. Abstract Light commercial

346

Development of an automated Red Light Violation Detection System (RLVDS) for Indian vehicles  

E-Print Network [OSTI]

Integrated Traffic Management Systems (ITMS) are now implemented in different cities in India to primarily address the concerns of road-safety and security. An automated Red Light Violation Detection System (RLVDS) is an integral part of the ITMS. In our present work we have designed and developed a complete system for generating the list of all stop-line violating vehicle images automatically from video snapshots of road-side surveillance cameras. The system first generates adaptive background images for each camera view, subtracts captured images from the corresponding background images and analyses potential occlusions over the stop-line in a traffic signal. Considering round-the-clock operations in a real-life test environment, the developed system could successfully track 92% images of vehicles with violations on the stop-line in a "Red" traffic signal.

Saha, Satadal; Nasipuri, Mita; Basu, Dipak Kumar

2010-01-01T23:59:59.000Z

347

A Buildings Module for the Stochastic Energy Deployment System  

E-Print Network [OSTI]

F.W. Dodge 1991: Building Stock Database Methodology andEnd-Use Flow Maps for the Buildings Sector, D.B. Belzer,N ATIONAL L ABORATORY A Buildings Module for the Stochastic

Marnay, Chris

2008-01-01T23:59:59.000Z

348

Co-Simulation of Building Energy and Control Systems with the Building Controls Virtual Test Bed  

E-Print Network [OSTI]

and a core zone. The envelope thermal properties meet ASHRAEis the thermal zone and the building envelope model that was

Wetter, Michael

2012-01-01T23:59:59.000Z

349

Optoelectronic ally automated system for carbon nanotubes synthesis via arc-discharge in solution  

SciTech Connect (OSTI)

The method of arc discharge in the solution is unique and inexpensive route for synthesis of the carbon nanotubes (CNTs), carbon onions, and other carbon nanostructures. Such a method can be used for in situ synthesis of CNTs decorated with nanoparticles. Herein, we report a simple and inexpensive optoelectronically automated system for arc discharge in solution synthesis of CNTs. The optoelectronic system maintains a constant gap between the two electrodes allowing a continuous synthesis of the carbon nanostructures. The system operates in a feedback loop consisting of an electrode-gap detector and an analog electronic unit, as controller. This computerized feeding system of the anode was used for in situ nanoparticles incorporated CNTs. For example, we have successfully decorated CNTs with ceria, silica, and palladium nanoparticles. Characterizations of nanostructures are performed using high-resolution transmission electron microscopy, scanning transmission electron microscopy, energy dispersive spectroscopy, and scanning electron microscopy.

Bera, Debasis; Brinley, Erik; Kuiry, Suresh C.; McCutchen, Matthew; Seal, Sudipta; Heinrich, Helge; Kabes, Bradley [Surface Engineering and Nanotechnology Facility - SNF, Advanced Materials Processing and Analysis Center - AMPAC, and Mechanical, Materials and Aerospace Engineering - MMAE, University of Central Florida - UCF, 4000 Central Florida Blvd., Eng 1, no. 381, Orlando, Florida 32816 (United States); Advanced Materials Processing and Analysis Center - AMPAC and Department of Physics, University of Central Florida, 4000 Central Florida Blvd., Eng 1, no. 381, Orlando, Florida 32816 (United States); NSF REU Site (UCF), Department of Chemical Engineering, University of Minnesota, Duluth, Minnesota 55803 (United States)

2005-03-01T23:59:59.000Z

350

Extending and automating a Systems-Theoretic hazard analysis for requirements generation and analysis.  

SciTech Connect (OSTI)

Systems Theoretic Process Analysis (STPA) is a powerful new hazard analysis method designed to go beyond traditional safety techniques - such as Fault Tree Analysis (FTA) - that overlook important causes of accidents like flawed requirements, dysfunctional component interactions, and software errors. While proving to be very effective on real systems, no formal structure has been defined for STPA and its application has been ad-hoc with no rigorous procedures or model-based design tools. This report defines a formal mathematical structure underlying STPA and describes a procedure for systematically performing an STPA analysis based on that structure. A method for using the results of the hazard analysis to generate formal safety-critical, model-based system and software requirements is also presented. Techniques to automate both the analysis and the requirements generation are introduced, as well as a method to detect conflicts between the safety and other functional model-based requirements during early development of the system.

Thomas, John (Massachusetts Institute of Technology)

2012-05-01T23:59:59.000Z

351

Automated Transportation Management System (ATMS) Software Project Management Plan (SPMP). Revision 2  

SciTech Connect (OSTI)

As a cabinet level federal agency with a diverse range of missions and an infrastructure spanning the United States, the US Department of Energy (DOE) has extensive freight transportation requirements. Performance and management of this freight activity is a critical function. DOE`s Transportation Management Division (TMD) has an agency-wide responsibility for overseeing transportation activities. Actual transportation operations are handled by government or contractor staff at the field locations. These staff have evolved a diverse range of techniques and procedures for performing transportation functions. In addition to minimizing the economic impact of transportation on programs, facility transportation staff must be concerned with the increasingly complex task of complying with complex shipment safety regulations. Maintaining the department`s safety record for shipping hazardous and radioactive materials is a primary goal. Use of automation to aid transportation functions is not widespread within DOE, though TMD has a number of software systems designed to gather and analyze data pertaining to field transportation activities. These systems are not integrated. Historically, most field facilities have accomplished transportation-related tasks manually or with minimal computer assistance. At best, information and decision support systems available to transportation staffs within the facilities are fragmented. In deciding where to allocate resources for automation, facility managers have not tended to give the needs of transportation departments a high priority. This diversity causes TMD significant difficulty in collecting data for use in managing department-wide transportation activities.

Weidert, R.S.

1995-05-26T23:59:59.000Z

352

Top: Rudder Tower is one of 24 Texas A&M buildings undergoing energy efficiency upgrades.  

E-Print Network [OSTI]

Top: Rudder Tower is one of 24 Texas A&M buildings undergoing energy efficiency upgrades. Bottom control energy costs and provide a greener, more energy efficient campus for a more environmentally' building automation system (BAS) will improve energy efficiency and enable better HVAC control in buildings

353

In vivo robotics: the automation of neuroscience and other intact-system biological fields  

E-Print Network [OSTI]

Robotic and automation technologies have played a huge role in in vitro biological science, having proved critical for scientific endeavors such as genome sequencing and high-throughput screening. Robotic and automation ...

Forest, Craig R.

354

Y-12 Plant decontamination and decommissioning Technology Logic Diagram for Building 9201-4: Volume 3, Technology evaluation data sheets: Part B, Decontamination; robotics/automation; waste management  

SciTech Connect (OSTI)

This volume consists of the Technology Logic Diagrams (TLDs) for the decontamination, robotics/automation, and waste management areas.

NONE

1994-09-01T23:59:59.000Z

355

Expert System for Building TRU Waste Payloads - 13554  

SciTech Connect (OSTI)

The process for grouping TRU waste drums into payloads for shipment to the Waste Isolation Pilot Plant (WIPP) for disposal is a very complex process. Transportation and regulatory requirements must be met, along with striving for the goals of shipment efficiency: maximize the number of waste drums in a shipment and minimize the use of empty drums which take up precious underground storage space. The restrictions on payloads range from weight restrictions, to limitations on flammable gas in the headspace, to minimum TRU alpha activity concentration requirements. The Overpack and Payload Assistant Tool (OPAT) has been developed as a mixed-initiative intelligent system within the WIPP Waste Data System (WDS) to guide the construction of multiple acceptable payloads. OPAT saves the user time while at the same time maximizes the efficiency of shipments for the given drum population. The tool provides the user with the flexibility to tune critical factors that guide OPAT's operation based on real-time feedback concerning the results of the execution. This feedback complements the user's external knowledge of the drum population (such as location of drums, known challenges, internal shipment goals). This work demonstrates how software can be utilized to complement the unique domain knowledge of the users. The mixed-initiative approach combines the insight and intuition of the human expert with the proficiency of automated computational algorithms. The result is the ability to thoroughly and efficiently explore the search space of possible solutions and derive the best waste management decision. (authors)

Bruemmer, Heather; Slater, Bryant [Information Systems Laboratories, 2235 East 25th Street, Suite 100, Idaho Falls, ID 83404 (United States)] [Information Systems Laboratories, 2235 East 25th Street, Suite 100, Idaho Falls, ID 83404 (United States)

2013-07-01T23:59:59.000Z

356

Database Supported Bacnet Data Acquisition System for Building Energy Diagnostics  

E-Print Network [OSTI]

Berkeley National Lab (LBNL) has developed a BACnet module in their co- simulation software ? Building Control Virtual Test Bed (BCVTB) [4]. The work introduced in this paper can be regarded as an extension of the work done in LBNL. Although BCVTB..., the database developed above has to be connected to a BACnet data acquisition system. BCVTB [2] is used in this study. It is a tool developed in Lawrence Berkeley National Lab (LBNL), on the basis of Ptolemy environment [7]. It has a module that leverages...

Li, Z.; Augenbroe, G.

2011-01-01T23:59:59.000Z

357

Building Pressure Control in VAV System with Relief Air Fan  

E-Print Network [OSTI]

, recently, Wang and Liu developed a motor power based fan airflow station., which determines the fan airflow using the measured fan motor power, the fan speed or control system command to VFD, and the in-situ fan motor power curve. Since the fan power... power can be obtained directly from VFD [5]. The motor power based fan airflow station method can be applied to the fan-tracking to perform a better building pressurization. The theory of the motor power based fan airflow station can be referred...

Pang, X.; Liu, M.; Zheng, B.

2005-01-01T23:59:59.000Z

358

VAV System Optimization through Continuous Commissioning in an Office Building  

E-Print Network [OSTI]

control Existing schedule: The existing control modulates the relief fan VFD to maintain the building pressure at its set-point (0.02 in.W.C). The relief damper is modulated according to the relief fan VFD speed. Table 3. Outside air damper.... AHU 2 serves the 3 rd , 4 th and 5 th floors. Both use similar control sequences, except that some parameter settings differ. The supply fans and relief fans have their respective VFD controls. One single-duct AHU system is shown in Figure 2...

Cho, Y.; Pang, X.; Liu, M.

2007-01-01T23:59:59.000Z

359

Building Smart Communities with Cyber-Physical Systems  

E-Print Network [OSTI]

There is a growing trend towards the convergence of cyber-physical systems (CPS) and social computing, which will lead to the emergence of smart communities composed of various objects (including both human individuals and physical things) that interact and cooperate with each other. These smart communities promise to enable a number of innovative applications and services that will improve the quality of life. This position paper addresses some opportunities and challenges of building smart communities characterized by cyber-physical and social intelligence.

Xia, Feng

2012-01-01T23:59:59.000Z

360

Assessment of the Current Level of Automation in the Manufacture of Fuel Cell Systems for Combined Heat and Power Applications  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) is interested in supporting manufacturing research and development (R&D) for fuel cell systems in the 10-1,000 kilowatt (kW) power range relevant to stationary and distributed combined heat and power applications, with the intent to reduce manufacturing costs and increase production throughput. To assist in future decision-making, DOE requested that the National Renewable Energy Laboratory (NREL) provide a baseline understanding of the current levels of adoption of automation in manufacturing processes and flow, as well as of continuous processes. NREL identified and visited or interviewed key manufacturers, universities, and laboratories relevant to the study using a standard questionnaire. The questionnaire covered the current level of vertical integration, the importance of quality control developments for automation, the current level of automation and source of automation design, critical balance of plant issues, potential for continuous cell manufacturing, key manufacturing steps or processes that would benefit from DOE support for manufacturing R&D, the potential for cell or stack design changes to support automation, and the relationship between production volume and decisions on automation.

Ulsh, M.; Wheeler, D.; Protopappas, P.

2011-08-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

A Scenario-based Predictive Control Approach to Building HVAC Management Systems  

E-Print Network [OSTI]

A Scenario-based Predictive Control Approach to Building HVAC Management Systems Alessandra Parisio and Air Conditioning (HVAC) systems while minimizing the overall energy use. The strategy uses

Johansson, Karl Henrik

362

Building Scientific Workflows for Earth System Modelling with Windows Workflow Foundation  

E-Print Network [OSTI]

Building Scientific Workflows for Earth System Modelling with Windows Workflow Foundation Matthew J developed a framework for the composition, execution and management of integrated Earth system models

363

Automated high-throughput flow-through real-time diagnostic system  

DOE Patents [OSTI]

An automated real-time flow-through system capable of processing multiple samples in an asynchronous, simultaneous, and parallel fashion for nucleic acid extraction and purification, followed by assay assembly, genetic amplification, multiplex detection, analysis, and decontamination. The system is able to hold and access an unlimited number of fluorescent reagents that may be used to screen samples for the presence of specific sequences. The apparatus works by associating extracted and purified sample with a series of reagent plugs that have been formed in a flow channel and delivered to a flow-through real-time amplification detector that has a multiplicity of optical windows, to which the sample-reagent plugs are placed in an operative position. The diagnostic apparatus includes sample multi-position valves, a master sample multi-position valve, a master reagent multi-position valve, reagent multi-position valves, and an optical amplification/detection system.

Regan, John Frederick

2012-10-30T23:59:59.000Z

364

Building a Global Federation System for Climate Change Research: The Earth System Grid Center for Enabling  

E-Print Network [OSTI]

Building a Global Federation System for Climate Change Research: The Earth System Grid Center for Enabling Technologies (ESG-CET) The Earth System Grid Center for Enabling Technologies Team: R Ananthakrishnan1 , D E Bernholdt7,9 , S Bharathi8 , D Brown5 , M Chen7 , A L Chervenak8 , L Cinquini5 , R Drach3

Chervenak, Ann

365

Energy efficiency in public buildings through ICT based control and monitoring systems  

E-Print Network [OSTI]

Energy efficiency in public buildings through ICT based control and monitoring systems G, France Keywords: energy efficiency, existing public buildings, control strategies, dynamic simulations a project entitled "Smart Energy Efficient Middleware for Public Spaces" (SEEMPubS). The project addresses

Paris-Sud XI, Université de

366

EPA ENERGY STAR Webcast: ENERGY STAR and Green Building Rating Systems  

Office of Energy Efficiency and Renewable Energy (EERE)

During this session, attendees will learn how to use EPA tools and resources to help meet requirements for green building rating systems such as the U.S. Green Building Council’s Leadership in...

367

Automation of System Safety Analysis: Possibilities and Pitfalls Andrew Galloway, University of York, Heslington, York YO10 5DD UK  

E-Print Network [OSTI]

evolved to support safety analysis work (in this paper, we use the term "safety analysis" to encompass all, safety engineers may only achieve closure at the end of a system's working life, when it is possibleAutomation of System Safety Analysis: Possibilities and Pitfalls Andrew Galloway, University

Pumfrey, David

368

Design and Implementation of an Open, Interoperable Automated Demand Response Infrastructure  

E-Print Network [OSTI]

is manual demand response -- where building staff receives aand Demand Response in Commercial Building. ,April, LBNL-Keywords: Demand response, automation, commercial buildings,

Piette, Mary Ann; Kiliccote, Sila; Ghatikar, Girish

2008-01-01T23:59:59.000Z

369

Development and evaluation of fully automated demand response in large facilities  

E-Print Network [OSTI]

and Demand Response in Commercial Buildings. ” LBNL Reportautomated Demand Response (DR) technologies in buildings.Automated Demand Response is initiated at a building or

Piette, Mary Ann; Sezgen, Osman; Watson, David S.; Motegi, Naoya; Shockman, Christine; ten Hope, Laurie

2004-01-01T23:59:59.000Z

370

Architecture Concepts and Technical Issues for an Open, Interoperable Automated Demand Response Infrastructure  

E-Print Network [OSTI]

is manual demand response -- where building staff receives aKeywords: Demand response, automation, commercial buildings,buildings, especially as it applies to Demand Response

Koch, Ed; Piette, Mary Ann

2008-01-01T23:59:59.000Z

371

THERMAL PERFORMANCE OF BUILDINGS AND BUILDING ENVELOPE SYSTEMS: AN ANNOTATED BIBLIOGRAPHY  

E-Print Network [OSTI]

dynamic test methods for envelope thermal performance whichtransieu~ thermal behavior of building envelopes, and theof dynamic thermal performance, of layered envelope construe

Carroll, William L.

2011-01-01T23:59:59.000Z

372

Software for fault detection in HVAC systems in commercial buildings  

E-Print Network [OSTI]

The building sector of the United States currently consumes over 41% of the United States primary energy supply. Estimates suggest that between 5 and 30% of any building's annual energy consumption is unknowingly wasted ...

Deshmukh, Suhrid Avinash

2014-01-01T23:59:59.000Z

373

Sustainability Assessment of Residential Building Energy System in Belgrade  

E-Print Network [OSTI]

of harmful substances. Multi-criteria method is a basic tool for the sustainability assessment in metropolitan cities. The design of potential options is the first step in the evaluation of buildings. The selection of a number of residential buildings...

Vucicevic, B.; Bakic, V.; Jovanovic, M.; Turanjanin, V.

2010-01-01T23:59:59.000Z

374

Improving Building Energy System Performance by Continuous Commissioning  

E-Print Network [OSTI]

data. The first buildings to undergo a continuous commissioning process were in the Texas LoanSTAR program [Liu, et al, 1994, Claridge, et al, 1994]. These buildings had been retrofitted with various energy efficiency improvements, and measured hourly...

Turner, W. D.; Liu, M.; Claridge, D. E.; Haberl, J. S.

1996-01-01T23:59:59.000Z

375

FORTRAN M AS A LANGUAGE FOR BUILDING EARTH SYSTEM MODELS \\Lambda  

E-Print Network [OSTI]

FORTRAN M AS A LANGUAGE FOR BUILDING EARTH SYSTEM MODELS \\Lambda Ian Foster Mathematics as a tool for building earth system models on massively parallel computers. I hypothesize that the use to investigate this hypothe­ sis. 2. Earth System Models An earth system model is a computer code designed

376

TCES Energy Performance 1. Overview of building systems  

E-Print Network [OSTI]

building heat supply about 25% of time in winter. Furnaces turn on while cogen heat supply is replenished

Schladow, S. Geoffrey

377

Automated Stellar Spectral Classification and Parameterization for the Masses  

E-Print Network [OSTI]

Stellar spectroscopic classification has been successfully automated by a number of groups. Automated classification and parameterization work best when applied to a homogeneous data set, and thus these techniques primarily have been developed for and applied to large surveys. While most ongoing large spectroscopic surveys target extragalactic objects, many stellar spectra have been and will be obtained. We briefly summarize past work on automated classification and parameterization, with emphasis on the work done in our group. Accurate automated classification in the spectral type domain and parameterization in the temperature domain have been relatively easy. Automated parameterization in the metallicity domain, formally outside the MK system, has also been effective. Due to the subtle effects on the spectrum, automated classification in the luminosity domain has been somewhat more difficult, but still successful. In order to extend the use of automated techniques beyond a few surveys, we present our current efforts at building a web-based automated stellar spectroscopic classification and parameterization machine. Our proposed machinery would provide users with MK classifications as well as the astrophysical parameters of effective temperature, surface gravity, mean abundance, abundance anomalies, and microturbulence.

Ted von Hippel; Carlos Allende Prieto; Chris Sneden

2002-08-08T23:59:59.000Z

378

Intelligent Building Control System for EPBD Certification Support  

E-Print Network [OSTI]

of intelligent HVAC buildings could provide not only the information needed for the operational control of building, but also to detect faults and to evaluate the energy performance of the building. Under the IEA Annex 47 project, authors started to develop...

Kabele, K.

2011-01-01T23:59:59.000Z

379

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis of solution characteristics using a two-body system  

E-Print Network [OSTI]

of innovative integrated HVAC systems in buildings, infor building envelope and HVAC systems simu- lation - WillIntegrated simulation for HVAC performance prediction: State

Trcka, Marija

2010-01-01T23:59:59.000Z

380

Impacts of Regional Electricity Prices and Building Type on the Economics of Commercial Photovoltaic Systems  

SciTech Connect (OSTI)

To identify the impacts of regional electricity prices and building type on the economics of solar photovoltaic (PV) systems, 207 rate structures across 77 locations and 16 commercial building types were evaluated. Results for expected solar value are reported for each location and building type. Aggregated results are also reported, showing general trends across various impact categories.

Ong, S.; Campbell, C.; Clark, N.

2012-12-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

A BEMS-Assisted Commissioning Tool to Improve the Energy Performance of HVAC Systems  

E-Print Network [OSTI]

The evolving capabilities of Building Energy Management Systems (BEMS) offer new opportunities to automate some parts of the commissioning process and can generate benefits over the entire life of a building. These benefits include a reduction...

Choiniere, D.; Corsi, M.

2003-01-01T23:59:59.000Z

382

Design and Implementation of an Open, Interoperable Automated Demand Response Infrastructure  

E-Print Network [OSTI]

of Fully Automated Demand Response in Large Facilities. CEC-Fully Automated Demand Response Tests in Large Facilities.Management and Demand Response in Commercial Building. ,

Piette, Mary Ann; Kiliccote, Sila; Ghatikar, Girish

2008-01-01T23:59:59.000Z

383

Synergy Between Building Rating Systems and Design Methodology for Intelligent and Green Buildings  

E-Print Network [OSTI]

. What is needed is a new integral design approach which enables to integrate the different aspects of green and intelligent buildings in a supportive framework during the design process. Especially the focus is on Multi Criteria Decision making within...

Zeiler, W.; Boxem, G.

384

An Application of State-Of-The-Art HVAC and Building Systems  

E-Print Network [OSTI]

AN APPLICATION OF STATE-OF-THE-ART HVAC AND BUILDING SYSTEMS DONALD P. FIORINO, M.S., P.E. Energy Conservation Manager Texas Instruments, Inc. Defense Systems and Electronics Group Dallas, Texas ABSTRACT This case study describes... the successful application of state-of-the-art HVAC and building systems at a large commercial office and industrial facility. The facility's exterior envelope systems, HVAC systems, lighting systems, energy conservation systems, exhaust/heat recovery...

Fiorino, D. P.

385

IEEE Robotics & Automation MagazineMARCH 2010 1070-9932/10/$26.002010 IEEE 1 USC CINAP Builds  

E-Print Network [OSTI]

ocean processes. Effective observation and continual monitoring of a dynamic system as complex a collection of static and mobile sensors, where the information gleaned from the acquired data is distributed, and the general public. To accomplish this task, the CINAPS team has designed and deployed an embedded sensor

Vincent, Warwick F.

386

Procedure for Measuring and Reporting the Performance of Photovoltaic Systems in Buildings  

SciTech Connect (OSTI)

This procedure provides a standard method for measuring and characterizing the long-term energy performance of photovoltaic (PV) systems in buildings and the resulting implications to the building's energy use. The performance metrics determined here may be compared against benchmarks for evaluating system performance and verifying that performance targets have been achieved. Uses may include comparison of performance with the design intent; comparison with other PV systems in buildings; economic analysis of PV systems in buildings; and the establishment of long-term performance records that enable maintenance staff to monitor trends in energy performance.

Pless, S.; Deru, M.; Torcellini, P.; Hayter, S.

2005-10-01T23:59:59.000Z

387

REDESIGN OF HVAC SYSTEM TO IMPROVE ENERGY EFFICIENCY OF EDUCATIONAL BUILDING.  

E-Print Network [OSTI]

??An energy modeling software was used to analyze the current building configuration and simulations were performed in an attempt to redesign the current HVAC system… (more)

Hagene, Brian Matthew

2012-01-01T23:59:59.000Z

388

An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

and Judkoff, R. 2002. IEA HVAC BESTEST volume 1, Technicaland Judkoff, R. 2004. IEA HVAC BESTEST volume 2, TechnicalOF INNOVATIVE INTEGRATED HVAC SYSTEMS IN BUILDINGS Marija

Trcka, Marija

2010-01-01T23:59:59.000Z

389

Small- and Medium-Size Building Automation and Control System Needs:  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage » SearchEnergyDepartmentScoping Study | Department of Energy Small- and

390

Small- and Medium-Size Building Automation and Control System Needs: Scoping Study  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustion |Energy Usage » SearchEnergyDepartmentScoping Study | Department of Energy Small-

391

Small- and Medium-Size Building Automation and Control System Needs:  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Office of Inspector GeneralDepartment of Energyof the Americas |DOE FormerEnergySaveP RSmall Column IonScoping

392

Application of an automated wireless structural monitoring system for long-span suspension bridges  

SciTech Connect (OSTI)

This paper describes an automated wireless structural monitoring system installed at the New Carquinez Bridge (NCB). The designed system utilizes a dense network of wireless sensors installed in the bridge but remotely controlled by a hierarchically designed cyber-environment. The early efforts have included performance verification of a dense network of wireless sensors installed on the bridge and the establishment of a cellular gateway to the system for remote access from the internet. Acceleration of the main bridge span was the primary focus of the initial field deployment of the wireless monitoring system. An additional focus of the study is on ensuring wireless sensors can survive for long periods without human intervention. Toward this end, the life-expectancy of the wireless sensors has been enhanced by embedding efficient power management schemes in the sensors while integrating solar panels for power harvesting. The dynamic characteristics of the NCB under daily traffic and wind loads were extracted from the vibration response of the bridge deck and towers. These results have been compared to a high-fidelity finite element model of the bridge.

Kurata, M.; Lynch, J. P. [Department of Civil and Environ. Eng., University of Michigan, Ann Arbor, MI 48105 (United States); Linden, G. W. van der [SC Solutions, Sunnyvale, CA 94085 (United States); Hipley, P.; Sheng, L.-H. [California Department of Transportation (Caltrans), Sacramento, CA 95816 (United States)

2011-06-23T23:59:59.000Z

393

THERMAL DISTRIBUTION SYSTEMS IN COMMERCIAL BUILDINGS Rick Diamond, Craig Wray, Darryl Dickerhoff, Nance Matson, and Duo Wang  

E-Print Network [OSTI]

1 THERMAL DISTRIBUTION SYSTEMS IN COMMERCIAL BUILDINGS Rick Diamond, Craig Wray, Darryl Dickerhoff SYSTEMS IN COMMERCIAL BUILDINGS 2 Acknowledgements Our largest debt of gratitude is to our Energy assistance guiding us through the EMCS system of the large commercial test building. The building management

394

EduCase : an automated lecture video recording, post-processing, and viewing system that utilizes multimodal inputs to provide a dynamic student experience  

E-Print Network [OSTI]

This thesis describes the design, implementation, and evaluation of EduCase: an inexpensive automated lecture video recording, post-processing, and viewing system. The EduCase recording system consists of three devices, ...

Itani, Sara T

2013-01-01T23:59:59.000Z

395

Singapore's Zero-Energy Building's daylight monitoring system  

E-Print Network [OSTI]

A and Mardaljevic J, Useful daylight illuminance: a newparadigm for assessing daylight in buildings, LightingJ and Rogers Z, Dynamic daylight performance metrics for

Grobe, Lars

2010-01-01T23:59:59.000Z

396

Real-Time Optimization Strategies for Building Systems  

E-Print Network [OSTI]

Our analysis indicates that it is possible to obtain energy savings of more ... building-wide, proactive, optimization, real-time, electricity markets, energy man-.

2011-09-02T23:59:59.000Z

397

Department of Mechanical and Nuclear Engineering Fall 2010 Wind Tunnel Automated Bicycle Adjustment System  

E-Print Network [OSTI]

PENN STATE Department of Mechanical and Nuclear Engineering Fall 2010 Wind Tunnel Automated Bicycle with the development of Aerofit's prototype portable wind tunnel used in the aerodynamic testing of bicycles was to automate this adjustment of the bicycle seat and aerobars in order to decrease the time for fitting each

Demirel, Melik C.

398

Low Cost Thin Film Building-Integrated Photovoltaic Systems  

SciTech Connect (OSTI)

The goal of the program is to develop 'LOW COST THIN FILM BUILDING-INTEGRATED PV SYSTEMS'. Major focus was on developing low cost solution for the commercial BIPV and rooftop PV market and meet DOE LCOE goal for the commercial market segment of 9-12 cents/kWh for 2010 and 6-8 cents/kWh for 2015. We achieved the 2010 goal and were on track to achieve the 2015 goal. The program consists of five major tasks: (1) modules; (2) inverters and BOS; (3) systems engineering and integration; (4) deployment; and (5) project management and TPP collaborative activities. We successfully crossed all stage gates and surpassed all milestones. We proudly achieved world record stable efficiencies in small area cells (12.56% for 1cm2) and large area encapsulated modules (11.3% for 800 cm2) using a triple-junction amorphous silicon/nanocrystalline silicon/nanocrystalline silicon structure, confirmed by the National Renewable Energy Laboratory. We collaborated with two inverter companies, Solectria and PV Powered, and significantly reduced inverter cost. We collaborated with three universities (Syracuse University, University of Oregon, and Colorado School of Mines) and National Renewable Energy Laboratory, and improved understanding on nanocrystalline material properties and light trapping techniques. We jointly published 50 technical papers in peer-reviewed journals and International Conference Proceedings. We installed two 75kW roof-top systems, one in Florida and another in New Jersey demonstrating innovative designs. The systems performed satisfactorily meeting/exceeding estimated kWh/kW performance. The 50/50 cost shared program was a great success and received excellent comments from DOE Manager and Technical Monitor in the Final Review.

Dr. Subhendu Guha; Dr. Jeff Yang

2012-05-25T23:59:59.000Z

399

ABV-A Low Speed Automation Project to Study the Technical Feasibility of Fully Automated Driving  

E-Print Network [OSTI]

on vehicle automation since many years. From 1987 to 1995 the European Commission funded the 800 million concepts of vehicles designed as fully automated vehicles [1]. Beyond its fully automation ability Automated Highway System Consortium (NAHSC) that demonstrated about 20 automated vehicles in Demo'97 on I-15

Paris-Sud XI, Université de

400

Systems and methods for controlling energy use in a building management system using energy budgets  

DOE Patents [OSTI]

Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A feedback controller is used to generate a manipulated variable based on an energy use setpoint and a measured energy use. The manipulated variable may be used for adjusting the operation of an HVAC device.

Wenzel, Michael J; Drees, Kirk H

2014-09-23T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Grid-Competitive Residential and Commercial Fully Automated PV Systems Technology: Final technical Report, August 2011  

SciTech Connect (OSTI)

Under DOE's Technology Pathway Partnership program, SunPower Corporation developed turn-key, high-efficiency residential and commercial systems that are cost effective. Key program objectives include a reduction in LCOE values to 9-12 cents/kWh and 13-18 cents/kWh respectively for the commercial and residential markets. Target LCOE values for the commercial ground, commercial roof, and residential markets are 10, 11, and 13 cents/kWh. For this effort, SunPower collaborated with a variety of suppliers and partners to complete the tasks below. Subcontractors included: Solaicx, SiGen, Ribbon Technology, Dow Corning, Xantrex, Tigo Energy, and Solar Bridge. SunPower's TPP addressed nearly the complete PV value chain: from ingot growth through system deployment. Throughout the award period of performance, SunPower has made progress toward achieving these reduced costs through the development of 20%+ efficient modules, increased cell efficiency through the understanding of loss mechanisms and improved manufacturing technologies, novel module development, automated design tools and techniques, and reduced system development and installation time. Based on an LCOE assessment using NREL's Solar Advisor Model, SunPower achieved the 2010 target range, as well as progress toward 2015 targets.

Brown, Katie E.; Cousins, Peter; Culligan, Matt; Jonathan Botkin; DeGraaff, David; Bunea, Gabriella; Rose, Douglas; Bourne, Ben; Koehler, Oliver

2011-08-26T23:59:59.000Z

402

Building Energy Information Systems: State of the Technology and User Case Studies  

SciTech Connect (OSTI)

The focus of this study is energy information systems, broadly defined as performance monitoring software, data acquisition hardware, and communication systems used to store, analyze, and display building energy data. At a minimum, an EIS provides hourly whole-building electric data that are web-accessible, with analytical and graphical capabilities. Time series data from meters, sensors, and external data streams are used to perofmr analysis such as baselining, benchmarking, building level anomaly detection, and energy performance tracking.

Granderson, Jessica; Piette, Mary Ann; Ghatikar, Girish; Price, Phillip

2009-10-01T23:59:59.000Z

403

Monitored Performance of an Office Building with an Under-floor Air Distribution System  

E-Print Network [OSTI]

- conditioning equipment was assessed and energy and ventilation improvements suggested. The building was found to fall within good practice and standard practice for energy usage in air-conditioned commercial office buildings for the United Kingdom.... However, if not installed or designed properly, these systems can use as much or more energy than a conventional HVAC system. The results of long-term monitoring and short-term measurements in a commercial office building with a UFAD are presented...

Walker, C.; Norford, L.

2005-01-01T23:59:59.000Z

404

Building Thermal Envelope Systems and Materials (BTESM) and research utilization/technology transfer  

SciTech Connect (OSTI)

The Monthly Report of the Building Thermal Envelope Systems and Materials (BTESM) Programs is a monthly update of both in-house ORNL projects and subcontract activities in the research areas of building materials, wall systems, foundations, roofs, building diagnostics, and research utilization and technology transfer. Presentations are not stand-alone paragraphs every month. Their principal values are the short-time lapse between accomplishment and reporting and their evolution over a period of several months..

Burn, G. (comp.)

1990-07-01T23:59:59.000Z

405

Transport Research Arena Europe 2010, Brussels Towards Highly Automated Driving  

E-Print Network [OSTI]

of HAVEit is to develop and investigate vehicle automation beyond ADAS systems, especially highly automated automated vehicles In 2010, two lines of research and development exist in the domain of ground vehicle automation: Either the automation is driving the vehicle fully automated without a human driver

Paris-Sud XI, Université de

406

Prototype Radiation Detector Positioning System For The Automated Nondestructive Assay Of Uf6 Cylinders  

SciTech Connect (OSTI)

International Atomic Energy Agency (IAEA) inspectors currently perform periodic inspections at uranium enrichment plants to verify UF6 cylinder enrichment declarations. Measurements are typically performed with handheld high-resolution sensors on a sampling of cylinders taken to be representative of the facility’s entire cylinder inventory. These measurements are time-consuming, expensive, and assay only a small fraction of the total cylinder volume. An automated nondestructive assay system capable of providing enrichment measurements over the full volume of the cylinder could improve upon current verification practices in terms of efficiency and assay accuracy. This paper describes an approach denoted the Integrated Cylinder Verification Station (ICVS) that supports 100% cylinder verification, provides volume-averaged cylinder enrichment assay, and reduces inspector manpower needs. To allow field measurements to be collected to validate data collection algorithms, a prototype radiation detector positioning system was constructed. The system was designed to accurately position an array of radiation detectors along the length of a cylinder to measure UF6 enrichment. A number of alternative radiation shields for the detectors were included with the system. A collimated gamma-ray spectrometer module that allows translation of the detectors in the surrounding shielding to adjust the field of view, and a collimating plug in the end to further reduce the low-energy field of view, were also developed. Proof-of-principle measurements of neutron and high-energy gamma-ray signatures, using moderated neutron detectors and large-volume spectrometers in a fixed-geometry, portal-like configuration, supported an early assessment of the viability of the concept. The system has been used successfully on two testing campaigns at an AREVA fuel fabrication plant to scan over 30 product cylinders. This paper will describe the overall design of the detector positioning system and provide an overview of the Integrated Cylinder Verification Station (ICVS) approach.

Hatchell, Brian K.; Valdez, Patrick LJ; Orton, Christopher R.; Mace, Emily K.

2011-08-07T23:59:59.000Z

407

Communication in automation, including networking and wireless  

E-Print Network [OSTI]

Communication in automation, including networking and wireless Nicholas Kottenstette and Panos J and networking in automation is given. Digital communication fundamentals are reviewed and networked control are presented. 1 Introduction 1.1 Why communication is necessary in automated systems Automated systems use

Antsaklis, Panos

408

Advancing Net-Zero Energy Commercial Buildings; Electricity, Resources, & Building Systems Integration (Fact Sheet)  

SciTech Connect (OSTI)

This fact sheet provides an overview of the research the National Renewable Energy Laboratory is conducting to achieve net-zero energy buildings (NZEBs). It also includes key definitions of NZEBs and inforamtion about an NZEB database that captures information about projects around the world.

Not Available

2009-10-01T23:59:59.000Z

409

Systems and methods for controlling energy use in a building management system using energy budgets  

SciTech Connect (OSTI)

Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A mathematical linear operator is found that transforms the unused or deferred cooling power usage of the HVAC system based on pre-determined temperature settings to a target cooling power usage. The mathematical operator is applied to the temperature settings to create a temperature setpoint trajectory expected to provide the target cooling power usage.

Wenzel, Michael J.

2012-06-17T23:59:59.000Z

410

Robofurnace: A semi-automated laboratory chemical vapor deposition system for high-throughput nanomaterial synthesis and process discovery  

SciTech Connect (OSTI)

Laboratory research and development on new materials, such as nanostructured thin films, often utilizes manual equipment such as tube furnaces due to its relatively low cost and ease of setup. However, these systems can be prone to inconsistent outcomes due to variations in standard operating procedures and limitations in performance such as heating and cooling rates restrict the parameter space that can be explored. Perhaps more importantly, maximization of research throughput and the successful and efficient translation of materials processing knowledge to production-scale systems, relies on the attainment of consistent outcomes. In response to this need, we present a semi-automated lab-scale chemical vapor deposition (CVD) furnace system, called “Robofurnace.” Robofurnace is an automated CVD system built around a standard tube furnace, which automates sample insertion and removal and uses motion of the furnace to achieve rapid heating and cooling. The system has a 10-sample magazine and motorized transfer arm, which isolates the samples from the lab atmosphere and enables highly repeatable placement of the sample within the tube. The system is designed to enable continuous operation of the CVD reactor, with asynchronous loading/unloading of samples. To demonstrate its performance, Robofurnace is used to develop a rapid CVD recipe for carbon nanotube (CNT) forest growth, achieving a 10-fold improvement in CNT forest mass density compared to a benchmark recipe using a manual tube furnace. In the long run, multiple systems like Robofurnace may be linked to share data among laboratories by methods such as Twitter. Our hope is Robofurnace and like automation will enable machine learning to optimize and discover relationships in complex material synthesis processes.

Oliver, C. Ryan; Westrick, William; Koehler, Jeremy; Brieland-Shoultz, Anna; Anagnostopoulos-Politis, Ilias; Cruz-Gonzalez, Tizoc [Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States)] [Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States); Hart, A. John, E-mail: ajhart@mit.edu [Department of Mechanical Engineering, University of Michigan, Ann Arbor, Michigan 48109 (United States); Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139 (United States)

2013-11-15T23:59:59.000Z

411

Co-Simulation of Detailed Whole Building with the Power System to Study Smart Grid Applications  

SciTech Connect (OSTI)

Modernization of the power system in a way that ensures a sustainable energy system is arguably one of the most pressing concerns of our time. Buildings are important components in the power system. First, they are the main consumers of electricity and secondly, they do not have constant energy demand. Conventionally, electricity has been difficult to store and should be consumed as it is generated. Therefore, maintaining the demand and supply is critical in the power system. However, to reduce the complexity of power models, buildings (i.e., end-use loads) are traditionally modeled and represented as aggregated “dumb” nodes in the power system. This means we lack effective detailed whole building energy models that can support requirements and emerging technologies of the smart power grid. To gain greater insight into the relationship between building energy demand and power system performance, it is important to constitute a co-simulation framework to support detailed building energy modeling and simulation within the power system to study capabilities promised by the modern power grid. This paper discusses ongoing work at Pacific Northwest National Laboratory and presents underlying tools and framework needed to enable co-simulation of building, building energy systems and their control in the power system to study applications such as demand response, grid-based HVAC control, and deployment of buildings for ancillary services. The optimal goal is to develop an integrated modeling and simulation platform that is flexible, reusable, and scalable. Results of this work will contribute to future building and power system studies, especially those related to the integrated ‘smart grid’. Results are also expected to advance power resiliency and local (micro) scale grid studies where several building and renewable energy systems transact energy directly. This paper also reviews some applications that can be supported and studied using the framework introduced to understand their implications before they can be successfully implemented in the power system.

Makhmalbaf, Atefe; Fuller, Jason C.; Srivastava, Viraj; Ciraci, Selim; Daily, Jeffrey A.

2014-12-24T23:59:59.000Z

412

Building-Integrated Photovoltaics (BIPV) in the Residential Sector: An Analysis of Installed Rooftop System Prices  

SciTech Connect (OSTI)

For more than 30 years, there have been strong efforts to accelerate the deployment of solar-electric systems by developing photovoltaic (PV) products that are fully integrated with building materials. This report examines the status of building-integrated PV (BIPV), with a focus on the cost drivers of residential rooftop systems, and explores key opportunities and challenges in the marketplace.

James, T.; Goodrich, A.; Woodhouse, M.; Margolis, R.; Ong, S.

2011-11-01T23:59:59.000Z

413

Towards Embedded Wireless-Networked Intelligent Daylighting Systems for Commercial Buildings  

E-Print Network [OSTI]

Towards Embedded Wireless-Networked Intelligent Daylighting Systems for Commercial Buildings Yao, daylighting systems are not widely used in the commercial office building. Barriers prohibiting adoption) `Smart Dust motes' wireless platforms is explored. Due to their small size, they can be placed directly

Agogino, Alice M.

414

Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems  

E-Print Network [OSTI]

Modelica Library for Building Heating, Ventilation and Air-Conditioning Systems Michael Wetter available Modelica library for building heating, ventilation and air conditioning systems. The library is based on the Modelica.Fluid library. It has been developed to support research and development

415

Revision Date: 8/29/11 ETME 425 -Building Systems Fall 2011  

E-Print Network [OSTI]

system integration. Incorporate the elements (pumps, fans, compressors, heat exchangers, heaters. HVAC Equipment 10. Sanitary Venting and Draining 3. Heat Loss and Heat Gain 7. Building Water Supply in modern buildings - including system selection, heating and cooling load calculations, component selection

Dyer, Bill

416

New automated inventory/material accounting system (AIMAS) version for former Soviet Union countries  

SciTech Connect (OSTI)

AIMAS (Automated Inventory/Material Accounting System) is a PC-based application for site-level nuclear material accountancy that was originally developed in the late 90's as a part of the U.S Department of Energy Assistance Program to Ukraine. Designed to be flexible and secure, plus place minimal demands on computing infrastructure, it was originally developed to run in early Windows operating system (OS) environments like W98 and W3.1. The development, support, and maintenance of AIMAS were transferred to Ukraine in 2002. Because it is highly flexible and can be configured to meet diverse end-user's needs, the software has been used at several facilities in Ukraine. Incorporating added functionality is planned to support nuclear installations in the Republic of Kazakhstan and Uzbekistan, as well. An improved 32-bit version of AIMAS has recently been developed to operate effectively on modern PCs running the latest Windows OS by AVIS, the Ukrainian developer. In the paper we discuss the status of AIMAS, plans for new functions, and describe the strategy for addressing a sustainable software life-cycle while meeting user requirements in multiple FSU countries.

Kuzminski, Jozef [Los Alamos National Laboratory; Ewing, Tom [ANL; Sakunov, Igor [AVIS CORP., KIEV, UKRAINE; Drapey, Sergey [GEORGE KUZMYCZ TRAINING; Nations, Jim [GREGG PROTECTION SERVICES

2009-01-01T23:59:59.000Z

417

Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.

Wang, Na; Gorrissen, Willy J.

2013-01-11T23:59:59.000Z

418

Integrated Building Energy Systems Design Considering Storage Technologies  

SciTech Connect (OSTI)

The addition of storage technologies such as flow batteries, conventional batteries, and heat storage can improve the economic, as well as environmental attraction of micro-generation systems (e.g., PV or fuel cells with or without CHP) and contribute to enhanced demand response. The interactions among PV, solar thermal, and storage systems can be complex, depending on the tariff structure, load profile, etc. In order to examine the impact of storage technologies on demand response and CO2 emissions, a microgrid's distributed energy resources (DER) adoption problem is formulated as a mixed-integer linear program that can pursue two strategies as its objective function. These two strategies are minimization of its annual energy costs or of its CO2 emissions. The problem is solved for a given test year at representative customer sites, e.g., nursing homes, to obtain not only the optimal investment portfolio, but also the optimal hourly operating schedules for the selected technologies. This paper focuses on analysis of storage technologies in micro-generation optimization on a building level, with example applications in New York State and California. It shows results from a two-year research projectperformed for the U.S. Department of Energy and ongoing work. Contrary to established expectations, our results indicate that PV and electric storage adoption compete rather than supplement each other considering the tariff structure and costs of electricity supply. The work shows that high electricity tariffs during on-peak hours are a significant driver for the adoption of electric storage technologies. To satisfy the site's objective of minimizing energy costs, the batteries have to be charged by grid power during off-peak hours instead of PV during on-peak hours. In contrast, we also show a CO2 minimization strategy where the common assumption that batteries can be charged by PV can be fulfilled at extraordinarily high energy costs for the site.

Stadler, Michael; Marnay, Chris; Siddiqui, Afzal; Lai, Judy; Aki, Hirohisa

2009-04-07T23:59:59.000Z

419

IZ-CON: an intelligent zone controller for building systems operation  

E-Print Network [OSTI]

into a number of well-formed sub-domains. Toward this end, a generative scheme for representation of buildings' systems control architecture is developed that allows for a structured distribution of systems' control logic. The scheme is cogently derived...

Mahdavi, A.; Schub, M.

2012-01-01T23:59:59.000Z

420

A Casebase of Intelligent Buildings for E-learning Systems  

E-Print Network [OSTI]

. The knowledge base aims to support currently used e-learning tools such as Blackboard, and to make a knowledge engine to facilitate other relevant research into intelligent buildings. A pilot knowledge base is introduced to demonstrate the usability...

Chen, Z.; Clements-Croome, D. J.; Ozkan, G.; Hong, J.; Xu, Z.

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Integrated Energy Systems (IES) for Buildings: A Market Assessment...  

Open Energy Info (EERE)

15 November, 2012 - 13:05 Literature Review The author analyzed the market of combine heat and power in commercial buildings. The paper provided the market size of CHP. It...

422

Potential of Evaporative Cooling Systems for Buildings in India  

E-Print Network [OSTI]

Evaporative cooling potential for building in various climatic zones in India is investigated. Maintainable indoor conditions are obtained from the load - capacity analysis for the prevailing ambient conditions. For the assumed activity level...

Maiya, M. P.; Vijay, S.

2010-01-01T23:59:59.000Z

423

On the development of a universal automated fixturing system through encapsulation techniques  

E-Print Network [OSTI]

Universal automated fixturing can transform a machine tool into a rapid prototyping machine with many advantages over current rapid prototyping methods. Using this modified machine tool, prototype parts can be manufactured ...

Lee, Elmer C., 1973-

2001-01-01T23:59:59.000Z

424

Context-based automated defect classification system using multiple morphological masks  

DOE Patents [OSTI]

Automatic detection of defects during the fabrication of semiconductor wafers is largely automated, but the classification of those defects is still performed manually by technicians. This invention includes novel digital image analysis techniques that generate unique feature vector descriptions of semiconductor defects as well as classifiers that use these descriptions to automatically categorize the defects into one of a set of pre-defined classes. Feature extraction techniques based on multiple-focus images, multiple-defect mask images, and segmented semiconductor wafer images are used to create unique feature-based descriptions of the semiconductor defects. These feature-based defect descriptions are subsequently classified by a defect classifier into categories that depend on defect characteristics and defect contextual information, that is, the semiconductor process layer(s) with which the defect comes in contact. At the heart of the system is a knowledge database that stores and distributes historical semiconductor wafer and defect data to guide the feature extraction and classification processes. In summary, this invention takes as its input a set of images containing semiconductor defect information, and generates as its output a classification for the defect that describes not only the defect itself, but also the location of that defect with respect to the semiconductor process layers.

Gleason, Shaun S. (Knoxville, TN); Hunt, Martin A. (Knoxville, TN); Sari-Sarraf, Hamed (Lubbock, TX)

2002-01-01T23:59:59.000Z

425

Optimizing RF gun cavity geometry within an automated injector design system  

SciTech Connect (OSTI)

RF guns play an integral role in the success of several light sources around the world, and properly designed and optimized cw superconducting RF (SRF) guns can provide a path to higher average brightness. As the need for these guns grows, it is important to have automated optimization software tools that vary the geometry of the gun cavity as part of the injector design process. This will allow designers to improve existing designs for present installations, extend the utility of these guns to other applications, and develop new designs. An evolutionary algorithm (EA) based system can provide this capability because EAs can search in parallel a large parameter space (often non-linear) and in a relatively short time identify promising regions of the space for more careful consideration. The injector designer can then evaluate more cavity design parameters during the injector optimization process against the beam performance requirements of the injector. This paper will describe an extension to the APISA software that allows the cavity geometry to be modified as part of the injector optimization and provide examples of its application to existing RF and SRF gun designs.

Alicia Hofler ,Pavel Evtushenko

2011-03-28T23:59:59.000Z

426

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2  

E-Print Network [OSTI]

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2 3 4 Peng Xu, Philip Haves HVAC system (air handling units and air distribution systems). The models are used to predict of automatic documentation methods in the library. INTRODUCTION The increasing complexity of building HVAC

427

E-Print Network 3.0 - automated synthesis module Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Towards Highly Automated Driving: Intermediate... of HAVEit is to develop and investigate vehicle automation beyond ADAS systems, especially highly automated... driving, where the...

428

Precursor systems analyses of automated highway systems: Commercial vehicle and transit ahs analysis. Volume 6. Final report, September 1993-February 1995  

SciTech Connect (OSTI)

This document is the final report of the Automated Highway System (AHS). The activities of Commercial Vehicle and Transit AHS Analysis are reported on in this document. This document type is resource materials. This volume is the six in a series. There are nine other volumes in the series.

Bottiger, F.; Chemnitz, H.D.; Doorman, J.; Franke, U.; Zimmerman, T.

1995-03-01T23:59:59.000Z

429

Hybrid Control Network Intrusion Detection Systems for Automated Power Distribution Systems  

E-Print Network [OSTI]

Security protocols against cyber attacks in the distributioncyber security weak- ness and system fragility of power distribution

Parvania, Masood; Koutsandria, Georgia; Muthukumar, Vishak; Peisert, Sean; McParland, Chuck; Scaglione, Anna

2014-01-01T23:59:59.000Z

430

Model Predictive Control Approach to Online Computation of Demand-Side Flexibility of Commercial Buildings HVAC Systems for Supply Following  

E-Print Network [OSTI]

of commercial building HVAC fan as ancillary service foralgorithm design for hvac systems in energy efficientoptimal control design for HVAC systems,” in Dynamic System

Maasoumy, Mehdi

2014-01-01T23:59:59.000Z

431

REAL-TIME, WEB BASED ENERGY MONITORING SYSTEM FOR A SOLAR ACADEMIC BUILDING John H. Scofield  

E-Print Network [OSTI]

Field Station incorporates passive solar cooling and active solar heating, maximizes ergonomicREAL-TIME, WEB BASED ENERGY MONITORING SYSTEM FOR A SOLAR ACADEMIC BUILDING John H. Scofield. The Leslie Shao-ming Sun Field Station is a 9,800 sf single- story building designed to help Jasper Ridge

Scofield, John H.

432

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture  

E-Print Network [OSTI]

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture Ariton E. Xhafa, Paisarn-- In this paper, we present an innovative solution to the handover problem in multi-story buildings using HVAC of the indoor wireless networks that use the heating, ventilation, and air conditioning (HVAC) ducts

Stancil, Daniel D.

433

Modeling and Optimization of Commercial Buildings and Stationary Fuel Cell Systems (Presentation)  

SciTech Connect (OSTI)

This presentation describes the Distributed Generation Building Energy Assessment Tool (DG-BEAT) developed by the National Renewable Energy Laboratory and the University of California Irvine. DG-BEAT is designed to allow stakeholders to assess the economics of installing stationary fuel cell systems in a variety of building types in the United States.

Ainscough, C.; McLarty, D.; Sullivan, R.; Brouwer, J.

2013-10-01T23:59:59.000Z

434

Building system integration research: recommendations for a US Department of Energy multiyear program plan  

SciTech Connect (OSTI)

This plan describes the scope, technical content, and resources required to conduct the Building System Integration (BSI) research program during FY 1987 through 1991. System integration research is defined, the need for the research is discussed, its benefits are outlined, and the history of building system integration research is summarized. The program scope, the general approach taken in developing this program plan, and the plan's contents are also described.

Not Available

1986-01-01T23:59:59.000Z

435

Automated High-Pressure Titration System with In Situ Infrared Spectroscopic Detection  

SciTech Connect (OSTI)

A fully automated titration system with infrared detection was developed for investigating interfacial chemistry at high pressures. The apparatus consists of a high-pressure fluid generation and delivery system coupled to a high-pressure cell with infrared optics. A manifold of electronically actuated valves is used to direct pressurized fluids into the cell. Precise reagent additions to the pressurized cell are made with calibrated tubing loops that are filled with reagent and placed in-line with the cell and a syringe pump. The cell’s infrared optics facilitate both transmission and attenuated total reflection (ATR) measurements to monitor bulk-fluid composition and solid-surface phenomena such as adsorption, desorption, complexation, dissolution, and precipitation. Switching between the two measurement modes is accomplished with moveable mirrors that direct radiation from a Fourier transform infrared spectrometer into the cell along transmission or ATR light paths. The versatility of the high-pressure IR titration system is demonstrated with three case studies. First, we titrated water into supercritical CO2 (scCO2) to generate an infrared calibration curve and determine the solubility of water in CO2 at 50 °C and 90 bar. Next, we characterized the partitioning of water between a montmorillonite clay and scCO2 at 50 °C and 90 bar. Transmission-mode spectra were used to quantify changes in the clay’s sorbed water concentration as a function of scCO2 hydration, and ATR measurements provided insights into competitive residency of water and CO2 on the clay surface and in the interlayer. Finally, we demonstrated how time-dependent studies can be conducted with the system by monitoring the carbonation reaction of forsterite (Mg2SiO4) in water-bearing scCO2 at 50 °C and 90 bar. Immediately after water dissolved in the scCO2, a thin film of adsorbed water formed on the mineral surface, and the film thickness increased with time as the forsterite began to dissolve. However, after approximately 2.5 hours, the trend reversed, and a carbonate precipitate began to form on the forsterite surface, exposing dramatic chemical changes in the thin-water film. Collectively, these applications illustrate how the high-pressure IR titration system can provide molecular-level information about the interactions between variably wet scCO2 and minerals relevant to underground storage of CO2 (geologic carbon sequestration). The apparatus could also be utilized to study high-pressure interfacial chemistry in other areas such as catalysis, polymerization, food processing, and oil and gas recovery.

Thompson, Christopher J.; Martin, Paul F.; Chen, Jeffrey; Benezeth, Pascale; Schaef, Herbert T.; Rosso, Kevin M.; Felmy, Andrew R.; Loring, John S.

2014-04-17T23:59:59.000Z

436

Automated high-pressure titration system with in situ infrared spectroscopic detection  

SciTech Connect (OSTI)

A fully automated titration system with infrared detection was developed for investigating interfacial chemistry at high pressures. The apparatus consists of a high-pressure fluid generation and delivery system coupled to a high-pressure cell with infrared optics. A manifold of electronically actuated valves is used to direct pressurized fluids into the cell. Precise reagent additions to the pressurized cell are made with calibrated tubing loops that are filled with reagent and placed in-line with the cell and a syringe pump. The cell's infrared optics facilitate both transmission and attenuated total reflection (ATR) measurements to monitor bulk-fluid composition and solid-surface phenomena such as adsorption, desorption, complexation, dissolution, and precipitation. Switching between the two measurement modes is accomplished with moveable mirrors that direct the light path of a Fourier transform infrared spectrometer into the cell along transmission or ATR light paths. The versatility of the high-pressure IR titration system was demonstrated with three case studies. First, we titrated water into supercritical CO{sub 2} (scCO{sub 2}) to generate an infrared calibration curve and determine the solubility of water in CO{sub 2} at 50?°C and 90 bar. Next, we characterized the partitioning of water between a montmorillonite clay and scCO{sub 2} at 50?°C and 90 bar. Transmission-mode spectra were used to quantify changes in the clay's sorbed water concentration as a function of scCO{sub 2} hydration, and ATR measurements provided insights into competitive residency of water and CO{sub 2} on the clay surface and in the interlayer. Finally, we demonstrated how time-dependent studies can be conducted with the system by monitoring the carbonation reaction of forsterite (Mg{sub 2}SiO{sub 4}) in water-bearing scCO{sub 2} at 50?°C and 90 bar. Immediately after water dissolved in the scCO{sub 2}, a thin film of adsorbed water formed on the mineral surface, and the film thickness increased with time as the forsterite began to dissolve. However, after approximately 2.5 h, the trend reversed, and a carbonate precipitate began to form on the forsterite surface, exposing dramatic chemical changes in the thin-water film. Collectively, these applications illustrate how the high-pressure IR titration system can provide molecular-level information about the interactions between variably wet scCO{sub 2} and minerals relevant to underground storage of CO{sub 2} (geologic carbon sequestration). The apparatus could also be utilized to study high-pressure interfacial chemistry in other areas such as catalysis, polymerization, food processing, and oil and gas recovery.

Thompson, Christopher J., E-mail: chris.thompson@pnnl.gov; Martin, Paul F.; Chen, Jeffrey; Schaef, Herbert T.; Rosso, Kevin M.; Felmy, Andrew R.; Loring, John S. [Pacific Northwest National Laboratory, Richland, Washington 99352 (United States)] [Pacific Northwest National Laboratory, Richland, Washington 99352 (United States); Benezeth, Pascale [Géosciences Environnement Toulouse (GET), CNRS-Université de Toulouse, 31400 Toulouse (France)] [Géosciences Environnement Toulouse (GET), CNRS-Université de Toulouse, 31400 Toulouse (France)

2014-04-15T23:59:59.000Z

437

Solar load ratio method applied to commercial building active solar system sizing  

SciTech Connect (OSTI)

The hourly simulation procedure is the DOE-2 building energy analysis computer program. It is capable of calculating the loads and of simulating various control strategies in detail for both residential and commercial buildings and yet is computationally efficient enough to be used for extensive parametric studies. In addition, to a Building Service Hot Water (BSHW) System and a combined space heating and hot water system using liquid collectors for a commercial building analyzed previously, a space heating system using an air collector is analyzed. A series of runs is made for systems using evacuated tube collectors for comparison to flat-plate collectors, and the effects of additional system design parameters are investigated. Also, the generic collector types are characterized by standard efficiency curves, rather than by detailed collector specifications. (MHR)

Schnurr, N.M.; Hunn, B.D.; Williamson, K.D. III

1981-01-01T23:59:59.000Z

438

PROJECT GOALS Use electricity accounts and Building Management System  

E-Print Network [OSTI]

benefits of altering lighting and computer management, and installing solar panels. Key recommendations The first energy saving option involved installing solar panels. Taking into account the parameters and power - were used to build baseline figures to gauge the impact of variations in temperature on total

439

Test Automation Ant JUnit Test Automation  

E-Print Network [OSTI]

Test Automation Ant JUnit Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2012 Mousavi: Test Automation #12;Test Automation Ant JUnit Outline Test Automation Ant JUnit Mousavi: Test Automation #12;Test Automation Ant JUnit Why? Challenges of Manual Testing

Mousavi, Mohammad

440

Initial findings: The integration of water loop heat pump and building structural thermal storage systems  

SciTech Connect (OSTI)

This report is one in a series of reports describing research activities in support of the US Department of Energy (DOE) Commercial Building System Integration Research Program. The goal of the program is to develop the scientific and technical basis for improving integrated decision-making during design and construction. Improved decision-making could significantly reduce buildings' energy use by the year 2010. The objectives of the Commercial Building System Integration Research Program are: to identify and quantify the most significant energy-related interactions among building subsystems; to develop the scientific and technical basis for improving energy related interactions in building subsystems; and to provide guidance to designers, owners, and builders for improving the integration of building subsystems for energy efficiency. The lead laboratory for this program is the Pacific Northwest Laboratory. A wide variety of expertise and resources from industry, academia, other government entities, and other DOE laboratories are used in planning, reviewing and conducting research activities. Cooperative and complementary research, development, and technology transfer activities with other interested organizations are actively pursued. In this report, the interactions of a water loop heat pump system and building structural mass and their effect on whole-building energy performance is analyzed. 10 refs., 54 figs., 1 tab.

Marseille, T.J.; Johnson, B.K.; Wallin, R.P.; Chiu, S.A.; Crawley, D.B.

1989-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Virtual Machine in Automation Projects.  

E-Print Network [OSTI]

?? Virtual machine, as an engineering tool, has recently been introduced into automation projects in Tetra Pak Processing System AB. The goal of this paper… (more)

Xing, Xiaoyuan

2010-01-01T23:59:59.000Z

442

The technical and economic feasibility of establishing a building system integration laboratory  

SciTech Connect (OSTI)

On December 22, 1987, the US Congress provided funding to the US Department of Energy (DOE) to study the feasibility and conceptual design of a whole building system integration laboratory'' (Title II of Pub. L. 100--202). A whole-building system integration laboratory would be a full-scale experimental facility in which the energy performance interactions of two or more building components, e.g., walls, windows, lighting, could be tested under actual operating conditions. At DOE's request, the Pacific Northwest Laboratory (PNL) conducted the study with the assistance of a technical review and representing other federal agencies and the academic and private sectors, including professional societies, building component manufacturers, and building research organizations. The results of the feasibility study are presented in this report.

Crawley, D.B.; Drost, M.K.; Johnson, B.M.

1989-09-01T23:59:59.000Z

443

Dynamic building enclosures : the design of an innovative constructive system which permits mechanically-driven, computer-controlled shape transformations to the building envelope  

E-Print Network [OSTI]

Dynamic Building Enclosures is a system of prefabricated, lightweight, kit-of-parts wall and/or roof elements. This system has the unique capability of dynamically altering, or mutating its shape in reaction to changing ...

Nelson, Eric (Eric Freeman), 1964-

1998-01-01T23:59:59.000Z

444

Energy Management Strategy for Commercial Buildings Integrating PV and Storage Systems  

E-Print Network [OSTI]

Energy Management Strategy for Commercial Buildings Integrating PV and Storage Systems He ZHANG1 by using the solution proposed. Keywords: Photovoltaic (PV) systems, fuzzy logic, storage system, energy connected to the power network and associated to photovoltaic and storage system. Some energy management

Paris-Sud XI, Université de

445

Building Urban Resilience and Sustainability (BURST): Integrating Adaptive Infrastructure Systems with Institutional and Ecological Functions  

E-Print Network [OSTI]

Building Urban Resilience and Sustainability (BURST): Integrating Adaptive Infrastructure Systems Professor, School of Architecture Ernesto Indacochea, Professor, Civil & Materials Engineering Kazuya with the sustainability paradigm. It is organized around the principle that resilient and sustainable infrastructures

Illinois at Chicago, University of

446

Frequency-based response of damped outrigger systems for tall buildings  

E-Print Network [OSTI]

The outrigger structural system for tall buildings is known to be effective in reducing lateral drift under quasi-static wind loading. Although keeping lateral deflection below the required value is certainly important, ...

Gamaliel, Renard

2008-01-01T23:59:59.000Z

447

Development of Energy Consumption Database Management System of Existing Large Public Buildings  

E-Print Network [OSTI]

The statistic data of energy consumption are the base of analyzing energy consumption. The scientific management method of energy consumption data and the development of database management system plays an important role in building energy...

Li, Y.; Zhang, J.; Sun, D.

2006-01-01T23:59:59.000Z

448

Investigation of a Novel Solar Assisted Water Heating System with Enhanced Energy Yield for Buildings  

E-Print Network [OSTI]

This paper presented the concept, prototype application, operational performance and benefits relating to a novel solar assisted water heating system for building services. It was undertaken through dedicated theoretical analysis, computer...

Zhang, X.; Zhao, X.; Xu, J.; Yu, X.

2012-01-01T23:59:59.000Z

449

Humidity Control Systems for Civil Buildings in Hot Summer and Cold Winter Zone in China  

E-Print Network [OSTI]

) systems. Based on our research, this paper further provides the rate and characteristics of moisture resources in civil buildings. Although the ventilation rate is limited with the minimum ventilation rate in the sanitation ventilation mode of the air...

Yu, X.

2006-01-01T23:59:59.000Z

450

Building a High-Level Dataflow System on top of Map-Reduce: The Pig Experience  

E-Print Network [OSTI]

Building a High-Level Dataflow System on top of Map-Reduce: The Pig Experience Alan F. Gates, Olga are open-source projects administered by the Apache Software Foundation. This paper describes

Olston, Christopher

451

Computational Study on Thermal Properties of HVAC System with Building Structure Thermal Storage  

E-Print Network [OSTI]

Building structure thermal storage (BSTS) HVAC systems can store heat during nighttime thermal storage operation (nighttime operation hours) by using off-peak electricity and release it in the daytime air-conditioning operation (daytime operation...

Sato, Y.; Sagara, N.; Ryu, Y.; Maehara, K.; Nagai, T.

2007-01-01T23:59:59.000Z

452

Building the DOE Systems Biology Knowledgebase (KBase) ( 7th Annual SFAF Meeting, 2012)  

ScienceCinema (OSTI)

Tom Brettin on "Building the DOE Systems Biology Knowledgebase (KBase)" at the 2012 Sequencing, Finishing, Analysis in the Future Meeting held June 5-7, 2012 in Santa Fe, New Mexico.

Brettin, Tom [Oak Ridge National Laboratory

2013-03-22T23:59:59.000Z

453

Solar Energy to Drive Absorption Cooling Systems Suitable for Small Building Applications  

E-Print Network [OSTI]

results and an overview of the performance of low capacity single stage and half-effect absorption cooling systems, suitable for residential and small building applications. The primary heat source is solar energy supplied from flat plate collectors...

Gomri, R.

2010-01-01T23:59:59.000Z

454

Co-Simulation of Building Energy and Control Systems with the Building Controls Virtual Test Bed  

E-Print Network [OSTI]

Proceedings of the 2nd Modelica conference, pages 55–1 – 55–Germany, March 2002. Modelica Association and Deutschesand Sven Erik Matts- son. Modelica for embedded systems. In

Wetter, Michael

2012-01-01T23:59:59.000Z

455

The integration of water loop heat pump and building structural thermal storage systems  

SciTech Connect (OSTI)

Many commercial buildings need heat in one part and, at the same time, cooling in another part. Even more common is the need for heating during one part of the day and cooling during another in the same spaces. If that energy could be shifted or stored for later use, significant energy might be saved. If a building's heating and cooling subsystems could be integrated with the building's structural mass and used to collect, store, and deliver energy, the energy might be save cost-effectively. To explore this opportunity, researchers at the Pacific Northwest Laboratory (PNL) examined the thermal interactions between the heating, ventilating, and air-conditioning (HVAC) system and the structure of a commercial building. Computer models were developed to simulate the interactions in an existing building located in Seattle, Washington, to determine how these building subsystems could be integrated to improve energy efficiency. The HVAC subsystems in the existing building were modeled. These subsystems consist of decentralized water-source heat pumps (WSHP) in a closed water loop, connected to cooling towers for heat rejection during cooling mode and boilers to augment heating. An initial base case'' computer model of the Seattle building, as-built, was developed. Metered data available for the building were used to calibrate this model to ensure that the analysis would provide information that closely reflected the operation of a real building. The HVAC system and building structure were integrated in the model using the concrete floor slabs as thermal storage media. The slabs may be actively charged during off-peak periods with the chilled water in the loop and then either actively or passively discharged into the conditioned space during peak periods. 21 refs., 37 figs., 17 tabs.

Marseille, T.J.; Schliesing, J.S.

1991-10-01T23:59:59.000Z

456

Peak Power Reduction Strategies for the Lighting Systems in Government Buildings  

E-Print Network [OSTI]

PEAK POWER REDUCTION STRATEGIES FOT THE LIGHTING SYSTEMS IN GOVERNMENT BUILDINGS Dina AlNakib CLEP, Dr. Ahmad Al-Mulla CEM, Gopal Maheshwari Department of Building and Energy Technologies Environment and Urban Development Division Kuwait... begins at 7:30 h and ends between 14:00 and 15:30 h. Lighting systems in MC building comprise mostly of T12 fluorescent tubes with magnetic ballasts, compact fluorescent lamps (CFLs) and incandescent lamps with a total connected load of 2,900 k...

Al-Nakib, D.; Al-Mulla, A. A.; Maheshwari, G. P.

2010-01-01T23:59:59.000Z

457

Decision process for the retrofit of municipal buildings with solar energy systems: a technical guide  

SciTech Connect (OSTI)

As a background for solar applications, the following topics are covered: solar systems and components for retrofit installations; cost, performance, and quality considerations; and financing alternatives for local government. The retrofit decision process is discussed as follows: pre-screening of buildings, building data requirements, the energy conservation audit, solar system sizing and economics, comparison of alternatives, and implementation. Sample studies are presented for the West Valley Animal Shelter and the Hollywood Police Station. (MHR)

None

1980-11-01T23:59:59.000Z

458

An Operational Energy Consumption Evaluation Index System for Large Public Buildings  

E-Print Network [OSTI]

ICEBO2006, Shenzhen, China Building Commissioning for Energy Efficiency and Comfort Vol.VII-2-2 An Operational Energy Consumption Evaluation Index System for Large Public Buildings1..., indexes system 1. PREFACE With the continuous development of urbanization level, the lack of energy and the increasing of society?s requirement for energy has become one of the prominent contradictions restricting the development of society...

Li, Y.; Zhang, J.; Sun, D.

2006-01-01T23:59:59.000Z

459

Weather Forecast Data an Important Input into Building Management Systems  

E-Print Network [OSTI]

it can generate as much or more energy that it needs ? Building activities need N kWhrs per day (solar panels, heating, etc) ? Harvested from solar panels & passive solar. Amount depends on weather ? NWP models forecast DSWRF @ surface (MJ/m2... contract work Saturday Would you plan work for Saturday? Not much detail for Saturday and Sunday With more info could be easier to decide go, no go From deterministic to probabilistic ? Forecast presented as a single scenario ? One scenario presented...

Poulin, L.

2013-01-01T23:59:59.000Z

460

Open Automated Demand Response Communications Specification (Version 1.0)  

SciTech Connect (OSTI)

The development of the Open Automated Demand Response Communications Specification, also known as OpenADR or Open Auto-DR, began in 2002 following the California electricity crisis. The work has been carried out by the Demand Response Research Center (DRRC), which is managed by Lawrence Berkeley National Laboratory. This specification describes an open standards-based communications data model designed to facilitate sending and receiving demand response price and reliability signals from a utility or Independent System Operator to electric customers. OpenADR is one element of the Smart Grid information and communications technologies that are being developed to improve optimization between electric supply and demand. The intention of the open automated demand response communications data model is to provide interoperable signals to building and industrial control systems that are preprogrammed to take action based on a demand response signal, enabling a demand response event to be fully automated, with no manual intervention. The OpenADR specification is a flexible infrastructure to facilitate common information exchange between the utility or Independent System Operator and end-use participants. The concept of an open specification is intended to allow anyone to implement the signaling systems, the automation server or the automation clients.

Piette, Mary Ann; Ghatikar, Girish; Kiliccote, Sila; Koch, Ed; Hennage, Dan; Palensky, Peter; McParland, Charles

2009-02-28T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Applications of Optimal Building Energy System Selection and Operation  

SciTech Connect (OSTI)

Berkeley Lab has been developing the Distributed Energy Resources Customer Adoption Model (DER-CAM) for several years. Given load curves for energy services requirements in a building microgrid (u grid), fuel costs and other economic inputs, and a menu of available technologies, DER-CAM finds the optimum equipment fleet and its optimum operating schedule using a mixed integer linear programming approach. This capability is being applied using a software as a service (SaaS) model. Optimisation problems are set up on a Berkeley Lab server and clients can execute their jobs as needed, typically daily. The evolution of this approach is demonstrated by description of three ongoing projects. The first is a public access web site focused on solar photovoltaic generation and battery viability at large commercial and industrial customer sites. The second is a building CO2 emissions reduction operations problem for a University of California, Davis student dining hall for which potential investments are also considered. And the third, is both a battery selection problem and a rolling operating schedule problem for a large County Jail. Together these examples show that optimization of building u grid design and operation can be effectively achieved using SaaS.

Marnay, Chris; Stadler, Michael; Siddiqui, Afzal; DeForest, Nicholas; Donadee, Jon; Bhattacharya, Prajesh; Lai, Judy

2011-04-01T23:59:59.000Z

462

Component Failure Behaviour: Patterns and Reuse in Automated System Safety Analysis  

E-Print Network [OSTI]

Trees and Failure Modes and Effects Analyses (FMEAs) can be automatically derived from a topological of failure patterns in conjunction with automated fault tree and FMEA synthesis algorithms can help on safety is universal, the issue is perhaps more urgent in the automotive industry which currently

Boyer, Edmond

463

Validating Predicted Rural Corridor Travel Times from an Automated License Plate Recognition System: Oregon's Frontier  

E-Print Network [OSTI]

: Oregon's Frontier Project Robert L. Bertini, Matthew Lasky, and Christopher M. Monsere Abstract automated license plate recognition­the Frontier Travel Time project. As part of the Frontier project, Montana, Wyoming, Texas, Washington, Utah, and Oregon) have formed the Frontier pooled-fund study which

Bertini, Robert L.

464

Move Frame Scheduling and Mixed SchedulingAllocation for the Automated Synthesis of Digital Systems y  

E-Print Network [OSTI]

steps: 1) Data path synthe­ sis (operation scheduling and hardware allocation), and 2) Control path design. In the scheduling phase, operations are assigned to the appropriate control steps. The allocaMove Frame Scheduling and Mixed Scheduling­Allocation for the Automated Synthesis of Digital

Nourani, Mehrdad

465

National Conference on Building Commissioning: April 19-21, 2006 A Guide for Specifying Performance Monitoring Systems in  

E-Print Network [OSTI]

Monitoring Systems in Commercial and Institutional Buildings Kenneth L. Gillespie, Jr. Pacific Gas & Electric commercial and institutional building owners in specifying what is required to obtain the information is the Leader of the Commercial Building Systems Group at Lawrence Berkeley National Laboratory. He has worked

466

automated guideway transit: Topics by E-print Network  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Automated Data Collection Systems, such as Automated Fare Collection (AFC) and Automatic Vehicle Location (AVL), provides ... Schil, Mickal (Mickal Ren Jerme) 2012-01-01...

467

Ball State building massive geothermal system | Department of Energy  

Energy Savers [EERE]

AFDC Printable Version Share this resource Send a link to EERE: Alternative Fuels Data Center Home Page to someone by E-mail Share EERE: Alternative Fuels Data Center Home Page on Facebook Tweet about EERE: Alternative Fuels Data Center Home Page on Twitter Bookmark EERE: Alternative Fuels Data Center Home Page on Google Bookmark EERE: Alternative Fuels Data Center Home Page on Delicious RankCombustionImprovement3--Logistical5/08 Attendance List1-02EvaluationJohnBall State building massive

468

PHOTOREALISTIC BUILDING MODELING AND VISUALIZATION IN 3-D GEOSPATIAL INFORMATION SYSTEM  

E-Print Network [OSTI]

PHOTOREALISTIC BUILDING MODELING AND VISUALIZATION IN 3-D GEOSPATIAL INFORMATION SYSTEM Yonghak: Despite geospatial information systems are widely used in many different fields as a powerful tool in geospatial information system (GIS). Such 3-D photorealistic visualization is able to provide geospatial

Shan, Jie

469

Comparison of Control Strategies for Energy Efficient Building HVAC Systems  

E-Print Network [OSTI]

optimal control design for HVAC systems. In Dynamic SystemOpti- mal control of HVAC systems in the presence of imper-consumption minimization of hvac sys- tems using model

Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2014-01-01T23:59:59.000Z

470

Proceedings of Healthy Buildings 2009 Paper 680 Do forced air HVAC systems have a role in healthy homes?  

E-Print Network [OSTI]

Proceedings of Healthy Buildings 2009 Paper 680 Do forced air HVAC systems have a role in healthy-extreme weather conditions. #12;Proceedings of Healthy Buildings 2009 Paper 680 Thus, a central forced air

Siegel, Jeffrey

471

A rationalized building system for low-income housing as a response to the issues of flexibility and participation  

E-Print Network [OSTI]

This thesis will focus on the design of a building system intending to approach the problem of low-income housing provision in developing countries.Two concepts will be proposed as a base for the development of the building ...

Spinazzola, Aida

1988-01-01T23:59:59.000Z

472

Integrated Building Energy Systems Design Considering Storage Technologies  

E-Print Network [OSTI]

photovoltaic, software, solar thermal systems Abstract Theinteractions among PV, solar thermal, and storage systemsstorage, PV, as well as solar thermal system adoption, two

Stadler, Michael

2009-01-01T23:59:59.000Z

473

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network [OSTI]

and Mehry Yazdanian. Comparisons of HVAC Simulations betweeninformation Comparison of HVAC System Simulations inCLT (kW) Comparison of HVAC System Simulations in Different

Zhou, Xin

2014-01-01T23:59:59.000Z

474

A Buildings Module for the Stochastic Energy Deployment System  

E-Print Network [OSTI]

Stochastic Energy Deployment System Chris Marnay a , Michael Stadler a, b , SamStochastic Energy Deployment System 1 Chris Marnay a) , Michael Stadler a),b) , Sam

Marnay, Chris

2008-01-01T23:59:59.000Z

475

The effects of level of automation and adaptive automation on human performance, situation awareness and workload in a  

E-Print Network [OSTI]

The effects of level of automation and adaptive automation on human performance, situation., 4731 East Forest Peak, Marietta, GA 30066, USA Keywords: Level of automation (LOA); adaptive automation of automation (LOAs) for maintaining operator involvement in complex systems control and facilitating situation

Kaber, David B.

476

Scalable Scheduling of Building Control Systems for Peak Demand Reduction  

E-Print Network [OSTI]

Behl, Rahul Mangharam and George J. Pappas Department of Electrical and Systems Engineering University operation of sub- systems such as heating, ventilating, air conditioning and refrigeration (HVAC&R) systems is fundamental for their efficient behavior, especially in elec- trical systems and the electric grid [1]. Peak

Pappas, George J.

477

Zone Level Occupant-Responsive Building Energy Systems at the GSA  

SciTech Connect (OSTI)

The General Services Administration (GSA) partnered with the U.S. Department of Energy (DOE) to develop and implement building energy system retrofits, aiming to reduce energy consumption of at least two building systems by a total of 30 percent or more, as part of DOE’s Commercial Building Partnership (CBP) Program. Lawrence Berkeley National Laboratory (LBNL) provided technical expertise in support of this DOE program, working with the GSA and a team of consultants. This case study reports expected energy savings from appropriate energy efficient design and operations modifications to lighting and heating, ventilating and air conditioning (HVAC) systems at the selected study sites. These retrofits comprised installation of new lighting systems with dimming capability and occupancy-sensor control at the individual light fixture level, and utilized lighting system occupancy sensor signals to continually readjust zone-level ventilation airflow according to the number of people present, down to minimum rates when vacant.

Robinson, Alastair

2014-03-01T23:59:59.000Z

478

Method and system for assigning a confidence metric for automated determination of optic disc location  

DOE Patents [OSTI]

A method for assigning a confidence metric for automated determination of optic disc location that includes analyzing a retinal image and determining at least two sets of coordinates locating an optic disc in the retinal image. The sets of coordinates can be determined using first and second image analysis techniques that are different from one another. An accuracy parameter can be calculated and compared to a primary risk cut-off value. A high confidence level can be assigned to the retinal image if the accuracy parameter is less than the primary risk cut-off value and a low confidence level can be assigned to the retinal image if the accuracy parameter is greater than the primary risk cut-off value. The primary risk cut-off value being selected to represent an acceptable risk of misdiagnosis of a disease having retinal manifestations by the automated technique.

Karnowski, Thomas P. (Knoxville, TN); Tobin, Jr., Kenneth W. (Harriman, TN); Muthusamy Govindasamy, Vijaya Priya (Knoxville, TN); Chaum, Edward (Memphis, TN)

2012-07-10T23:59:59.000Z

479

System Integration of Distributed Power for Complete Building Systems: Phase 1 Report  

SciTech Connect (OSTI)

This report describes NiSource Energy Technologies Inc.'s base year of a planned 3-year effort to advance distributed power development, deployment, and integration. Its long-term goal is to design ways to extend distributed generation into the physical design and controls of buildings. NET worked to meet this goal through advances in the implementation and control of CHP systems in end-user environments and a further understanding of electric interconnection and siting issues. Important results from the first year were a survey of the state of the art of interconnection issues associated with distributed generation, a survey of the local zoning requirements for the NiSource service territory, and the acquisition of data about the operation, reliability, interconnection, and performance of CHP systems and components of two test sites.

Kramer, R.

2003-12-01T23:59:59.000Z

480

Reducing Building Energy Costs Using Optimized Operation Strategies for Constant Volume Air Handling Systems  

E-Print Network [OSTI]

SDCVP 67.380 $153.200 $41.800 $195.000 $2.89 measured energy consumption for each building. The horizontal axis is the ambient temperature. The venical axis is the average daily energy consumption in MMBtulhr. Figure 5 compares the predicted...REDUCING BUILDING ENERGY COSTS USING OPTIMIZED OPERATION STRATEGIES FOR CONSTANT VOLUME AIR HANDLING SYSTEMS Mingsheng Liu, her Atha, Agarni Reddy Ed White David Claridge and Jeff Haberl Department of Physical Plant Texas A&M University...

Liu, M.; Athar, A.; Reddy, A.; Claridge, D. E.; Haberl, J. S.; White, E.

1994-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Estimating Demand Response Load Impacts: Evaluation of Baseline Load Models for Non-Residential Buildings in California  

E-Print Network [OSTI]

commercial buildings participating in a demand?response (buildings participating in an Automated Demand Response buildings  participating  in  an  event?driven  demand?response  (

Coughlin, Katie; Piette, Mary Ann; Goldman, Charles; Kiliccote, Sila

2008-01-01T23:59:59.000Z

482

Apparatus for mounting photovoltaic power generating systems on buildings  

DOE Patents [OSTI]

Rectangular photovoltaic (PV) modules are mounted on a building roof by mounting stands that are distributed in rows and columns. Each stand comprises a base plate and first and second different height brackets attached to opposite ends of the base plate. Each first and second bracket comprises two module-support members. One end of each module is pivotally attached to and supported by a first module-support member of a first bracket and a second module-support member of another first bracket. At its other end each module rests on but is connected by flexible tethers to module-support members of two different second brackets. The tethers are sized to allow the modules to pivot up away from the module-support members on which they rest to a substantially horizontal position in response to wind uplift forces.

Russell, Miles C. (Lincoln, MA)

2009-08-18T23:59:59.000Z

483

An Integrated Air Handling Unit System for Large Commercial Buildings  

E-Print Network [OSTI]

are developed to compare the energy performance and indoor air quality between the OAHU and conventional AHU systems (single AHU). The OAHU uses significantly less energy than the conventional system in both winter and summer. The OAHU also provides better...

Song, L.; Liu, M.

2001-01-01T23:59:59.000Z

484

Innovative Systems for Solar Air Conditioning of Buildings  

E-Print Network [OSTI]

for a high efficient utilization of solar thermal energy. To show the today's and near future potential innovative solar cooling and air conditioning systems are discussed which are well adapted to the utilization of solar energy. The system performance...

Kessling, W.; Peltzer, M.

2004-01-01T23:59:59.000Z

485

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network [OSTI]

Four Pipe Fan Coil; Four Pipe Induction Unit; Heating andTwo Pipe Fan Coil; Two Pipe Induction Unit; Unit Heater;units (AHUs) – four CAV systems, four VAV systems, and one fan coil

Zhou, Xin

2014-01-01T23:59:59.000Z

486

Analysis of advanced solar hybrid desiccant cooling systems for buildings  

SciTech Connect (OSTI)

This report describes an assessment of the energy savings possible from developing hybrid desiccant/vapor-compression air conditioning systems. Recent advances in dehumidifier design for solar desiccant cooling systems have resulted in a dehumidifier with a low pressure drop and high efficiency in heat and mass transfer. A recent study on hybrid desiccant/vapor compression systems showed a 30%-80% savings in resource energy when compared with the best conventional systems with vapor compression. A system consisting of a dehumidifier with vapor compression subsystems in series was found to be the simplest and best overall performer.

Schlepp, D.; Schultz, K.

1984-10-01T23:59:59.000Z

487

Disciplined agility for process control & automation  

E-Print Network [OSTI]

Process automation vendors must consider agility as a basis to gain a competitive edge in innovation. Process Automation systems can impact the operating cost of manufacturing equipment, the safe control of large quantities ...

Tibazarwa, Augustine

2009-01-01T23:59:59.000Z

488

Case study of verification, validation, and testing in the Automated Data Processing (ADP) system development life cycle  

SciTech Connect (OSTI)

Staff of the Environmental Assessment and Information Sciences Division of Argonne National Laboratory (ANL) studies the role played by the organizational participants in the Department of Veterans Affairs (VA) that conduct verification, validation, and testing (VV T) activities at various stages in the automated data processing (ADP) system development life cycle (SDLC). A case-study methodology was used to assess the effectiveness of VV T activities (tasks) and products (inputs and outputs). The case selected for the study was a project designed to interface the compensation and pension (C P) benefits systems with the centralized accounts receivable system (CARS). Argonne developed an organizational SDLC VV T model and checklists to help collect information from C P/CARS participants on VV T procedures and activities, and these were then evaluated against VV T standards.

Riemer, C.A.

1990-05-01T23:59:59.000Z

489

Design of an Automated System for Synthesis of [18 F] FDG for PET Investigation at IFIN-HH Bucharest  

SciTech Connect (OSTI)

A novel apparatus constructed at IFIN-HH is described for automated synthesis of radiopharmaceuticals labeled with {sup 18}F for use in positron emission tomography (PET) investigations. [18 F] fluoride was produced at the IFIN-HH cyclotron by irradiation of H{sub 2}O enriched 97% in {sup 18}O with 13 MeV deuterons, or 8 MeV protons. The irradiated H{sub 2}O was transferred (injected) into the radiochemical fully-automated processing systems which ensured the separation of {sup 18}F from H{sub 2}O, the labeling with {sup 18}F, and finally purified by filtration with selective absorbants. The system is easy to operate and contains a programmable logical controller that manages the entire operation program stored in its internal memory. The computer is used to assist the operator during the different steps of synthesis and to allow visualization of the process and printing the report. The device was used for used for the production of 2-[18 F] FLUORO-2-DEOXY-D-GLUCOSE at the IFIN-HH cyclotron, one of the most used radiopharmaceutical in PET investigations. The synthesis module is configured so that is flexible enough to accomplish other nucleophile reactions of labeling with short lived radioisotopes.

Craciun, Liviu Stefan; Cimpeanu, Catalina; Constantinescu, Olimpiu; Dudu, Dorin; Ionescu, Cristina; Negoita, Nicolae; Racolta, Petru Mihai; Rusen, Ion [Applied Nuclear Physics Department, 'Horia Hulubei' National Institute for Physics and Nuclear Engineering, Atomistilor 407, P.O. Box MG-6, Magurele, jud. Ilfov, Bucharest R-077125 (Romania)

2009-03-10T23:59:59.000Z

490

Energy Performance Comparison of Heating and Air Conditioning Systems for Multi-Family Residential Buildings  

SciTech Connect (OSTI)

The type of heating, ventilation and air conditioning (HVAC) system has a large impact on the heating and cooling energy consumption in multifamily residential buildings. This paper compares the energy performance of three HVAC systems: a direct expansion (DX) split system, a split air source heat pump (ASHP) system, and a closed-loop water source heat pump (WSHP) system with a boiler and an evaporative fluid cooler as the central heating and cooling source. All three systems use gas furnace for heating or heating backup. The comparison is made in a number of scenarios including different climate conditions, system operation schemes and applicable building codes. It is found that with the minimum code-compliant equipment efficiency, ASHP performs the best among all scenarios except in extremely code climates. WSHP tends to perform better than the split DX system in cold climates but worse in hot climates.

Wang, Weimin; Zhang, Jian; Jiang, Wei; Liu, Bing

2011-07-31T23:59:59.000Z

491

Contributing to Net Zero Building: High Energy Efficient EIFS Wall Systems  

SciTech Connect (OSTI)

The team led by Dow Corning collaborated to increase the thermal performance of exterior insulation and finishing systems (EIFS) to reach R-40 performance meeting the needs for high efficiency insulated walls. Additionally, the project helped remove barriers to using EIFS on retrofit commercial buildings desiring high insulated walls. The three wall systems developed within the scope of this project provide the thermal performance of R-24 to R-40 by incorporating vacuum insulation panels (VIPs) into an expanded polystyrene (EPS) encapsulated vacuum insulated sandwich element (VISE). The VISE was incorporated into an EIFS as pre-engineered insulation boards. The VISE is installed using typical EIFS details and network of trained installers. These three wall systems were tested and engineered to be fully code compliant as an EIFS and meet all of the International Building Code structural, durability and fire test requirements for a code compliant exterior wall cladding system. This system is being commercialized under the trade name Dryvit® Outsulation® HE system. Full details, specifications, and application guidelines have been developed for the system. The system has been modeled both thermally and hygrothermally to predict condensation potential. Based on weather models for Baltimore, MD; Boston, MA; Miami, FL; Minneapolis, MN; Phoenix, AZ; and Seattle, WA; condensation and water build up in the wall system is not a concern. Finally, the team conducted a field trial of the system on a building at the former Brunswick Naval Air Station which is being redeveloped by the Midcoast Regional Redevelopment Authority (Brunswick, Maine). The field trial provided a retrofit R-30 wall onto a wood frame construction, slab on grade, 1800 ft2 building, that was monitored over the course of a year. Simultaneous with the façade retrofit, the building’s windows were upgraded at no charge to this program. The retrofit building used 49% less natural gas during the winter of 2012 compared to previous winters. This project achieved its goal of developing a system that is constructible, offers protection to the VIPs, and meets all performance targets established for the project.

Carbary, Lawrence D. [Dow Corning Corporation] [Dow Corning Corporation; Perkins, Laura L. [Dow Corning Corporation] [Dow Corning Corporation; Serino, Roland [Dryvit Systems, Inc] [Dryvit Systems, Inc; Preston, Bill [Dryvit Systems, Inc] [Dryvit Systems, Inc; Kosny, Jan [Fraunhofer USA, Inc. CSE] [Fraunhofer USA, Inc. CSE

2014-01-29T23:59:59.000Z

492

Using XML to Build Efficient Transaction-Time Temporal Database Systems on Relational Databases  

E-Print Network [OSTI]

(virtual) representations of the database history, (b) XQuery to express powerful temporal queriesUsing XML to Build Efficient Transaction-Time Temporal Database Systems on Relational Databases the ArchIS system that achieves full-functionality transaction-time databases without re- quiring temporal

Zaniolo, Carlo

493

Project Control in Integrated Building Design Systems Godfried Augenbroe* and Robert Amor**  

E-Print Network [OSTI]

Project Control in Integrated Building Design Systems Godfried Augenbroe* and Robert Amor of research into integrated design systems that allow communication between multiple actors and design tools acceptance if, apart from providing 'generic integration facilities', adequate tools are provided to design

Amor, Robert

494

AER Building Blocks for Multi-Layer Multi-Chip Neuromorphic Vision Systems  

E-Print Network [OSTI]

AER Building Blocks for Multi-Layer Multi-Chip Neuromorphic Vision Systems R. Serrano-Gotarredona1 the address-event- representation (AER) is demonstrated. The system includes a retina chip, two convolution and measurements results are shown. 1 Introduction The Address-Event-Representation (AER) is an event

Häfliger, Philipp

495

Intelligent Building Energy Information and Control Systems for Low-Energy  

E-Print Network [OSTI]

of these areas and suggests how future integrated control systems should be designed and operatedLBNL-5894E Intelligent Building Energy Information and Control Systems for Low-Energy Operations Berkeley National Laboratory May 2012 Published in IEEE Design and Test of Computers #12;DISCLAIMER

496

Building America Webinar: High Performance Space Conditioning Systems, Part II  

Broader source: Energy.gov [DOE]

The webinar on Nov. 18, 2014, continued the series on strategies to improve the performance of HVAC systems for low load homes and home performance retrofits.

497

Building America Webinar: High Performance Space Conditioning Systems, Part I  

Broader source: Energy.gov [DOE]

The webinar on Oct. 23, 2014 focused on strategies to improve the performance of HVAC systems for low load homes and home performance retrofits.

498

Fault Detection and Diagnosis in Building HVAC Systems  

E-Print Network [OSTI]

Wright, “Condition monitoring in HVAC subsystems using firstmonitoring packaged HVAC equipment. ASHRAE Transactions”,Detection and Diagnosis of HVAC Systems Using Support Vector

Najafi, Massieh

2010-01-01T23:59:59.000Z

499

City of Portland- Streamlined Building Permits for Residential Solar Systems  

Broader source: Energy.gov [DOE]

The City of Portland's Bureau of Development Services (BDS) developed an electronic permitting process for residential solar energy system installations. With this streamlined, expedited process,...

500

Quality Management System Guidelines - Building America Top Innovation...  

Energy Savers [EERE]

(PHI) created custom quality management system guidelines for the design and construction of high performance homes, earning a 2013 Top Innovation award for their efforts....