Powered by Deep Web Technologies
Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Development of Building Automation and Control Systems  

E-Print Network [OSTI]

A design flow for building automation and control systems,’’Development of Building Automation and Control Systems Yangdesign of the build- ing automation system (including the

Yang, Yang; Zhu, Qi; Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

2

Small- and Medium-Size Building Automation and Control System...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Emerging...

3

Development of Building Automation and Control Systems  

E-Print Network [OSTI]

Johnson Controls, 70 in Automated Logic EIKON language, 42systems developed by Automated Logic. Similarly as shown in

Yang, Yang; Zhu, Qi; Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

4

Building automation systems (BAS) are concerned with control and monitoring of buildings, while aiming to  

E-Print Network [OSTI]

Building automation systems (BAS) are concerned with control and monitoring of buildings, while alarm systems or physical access control), · control the climate in the building/supervise and control operating and energy costs Realization and Experiences with a Low-Cost Building Automation Security Testbed

Behnke, Sven

5

Final Draft Building Automation Systems Design and Construction Standards October 3rd  

E-Print Network [OSTI]

Final Draft Building Automation Systems Design and Construction Standards October 3rd , 2013 1 Building Automation System Design and Construction Standards University of Rochester Utilities and Energy Automation Systems Design and Construction Standards October 3rd , 2013 2 University of Rochester Building

Portman, Douglas

6

Small- and Medium-Size Building Automation and Control System Needs: Scoping Study  

Broader source: Energy.gov (indexed) [DOE]

Small- and Medium-Size Building Automation and Control System Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Michael Brambley, Ph.D. Pacific Northwest National Laboratory Michael.Brambley@pnnl.gov (509) 375-6875 April 2, 2013 2 | Building Technologies Office eere.energy.gov Problem Statement * Less than 10% of the buildings have building automation systems (BAS) * Over 90% of buildings stock either: - small (<5,000 sf) or - medium-sized (between 5,000 sf and 50,000 sf)

7

Small- and Medium-Size Building Automation and Control System Needs: Scoping Study  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Small- and Medium-Size Building Automation and Control System Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Michael Brambley, Ph.D. Pacific Northwest National Laboratory Michael.Brambley@pnnl.gov (509) 375-6875 April 2, 2013 2 | Building Technologies Office eere.energy.gov Problem Statement * Less than 10% of the buildings have building automation systems (BAS) * Over 90% of buildings stock either: - small (<5,000 sf) or - medium-sized (between 5,000 sf and 50,000 sf)

8

Small and Medium-Sized Building Automation and Control System Needs Scoping  

Broader source: Energy.gov (indexed) [DOE]

Small and Medium-Sized Building Automation Small and Medium-Sized Building Automation and Control System Needs Scoping Study Small and Medium-Sized Building Automation and Control System Needs Scoping Study The U.S. Department of Energy (DOE) is currently conducting a scoping research study of small- and medium-sized building automation and control system needs. Project Description This project seeks to develop a scoping study to identify the building automation system needs-such as end-uses and systems to be controlled-and control capabilities for small- and medium-sized buildings. Researchers also plan to develop a case study to show that building controls for small- and medium-sized buildings can be cost-effective. The monitoring needs to ensure proper and persistent operations will also be identified.

9

A Distributed Facilities Automation System For IBM Buildings  

E-Print Network [OSTI]

protocol. This will allow the facility manager to take advantage of the expertise of ~any control system suppliers while retaining central control, override authority, and specialized manage ment functions. A distributed facilities automation system... protocol. This will allow the facility manager to take advantage of the expertise of ~any control system suppliers while retaining central control, override authority, and specialized manage ment functions. A distributed facilities automation system...

Houle, W. D. Sr.

10

Building Automation Systems Design. Guidelines for Systems with Complex Requirements.  

E-Print Network [OSTI]

??Buildings today are becoming more and more advanced and the demands on building services are increasing. A modern building is expected to provide a number… (more)

Kensby, Johan

2012-01-01T23:59:59.000Z

11

Building America Expert Meeting: Minutes from Automated Home Energy Management System  

Broader source: Energy.gov [DOE]

These meeting minutes are from the U.S. Department of Energy Building America program expert meeting titled "Automated Home Energy Management System," held on October 1-2, 2010 in Denver, Colorado.

12

FEMP Presents Its Newest On-Demand eTraining Course on Building Automation Systems  

Broader source: Energy.gov [DOE]

The U.S. Department of Energy (DOE) Federal Energy Management Program (FEMP) has launched its latest eTraining Course, Building Automation Systems for Existing Federal Facilities for no-cost, on-demand access.

13

Chapter 13 - Commercial Building Automation  

Science Journals Connector (OSTI)

A Building Automation System (BAS) is a computerized, intelligent system that controls and measures lighting, climate, security, and other mechanical and electrical systems in a building. The purpose of a BAS is typically to reduce energy and maintenance costs, as well as to increase control, comfort, reliability, and ease of use for maintenance staff and tenants.

Jan Höller; Vlasios Tsiatsis; Catherine Mulligan; Stamatis Karnouskos; Stefan Avesand; David Boyle

2014-01-01T23:59:59.000Z

14

Initial and Continuous Commissioning of Building Automation and Control Systems (BACS) -Preview EN ISO 16484-  

E-Print Network [OSTI]

8th International Conference for Enhanced Building Operations - ICEBO?08 Conference Center of the Federal Ministry of Economics and Technology Berlin, October 20 - 22, 2008 Dipl.-Ing. Hans R. Kranz VDI HAK Consulting Enzstrasse 10 76694... Forst 0 04 91 72/ 2 92 60 21 hans@kranz.com INITIAL AND CONTINUOUS COMMISSIONING OF BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PREVIEW EN ISO 16484 - Did you ever think about: ?why are our buildings so dumb?? The simple answer might be...

Kranz, H. R.

2008-01-01T23:59:59.000Z

15

Building Technologies Office: Small- and Medium-Sized Building Automation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Small- and Medium-Sized Small- and Medium-Sized Building Automation and Control System Needs: Scoping Study Research Project to someone by E-mail Share Building Technologies Office: Small- and Medium-Sized Building Automation and Control System Needs: Scoping Study Research Project on Facebook Tweet about Building Technologies Office: Small- and Medium-Sized Building Automation and Control System Needs: Scoping Study Research Project on Twitter Bookmark Building Technologies Office: Small- and Medium-Sized Building Automation and Control System Needs: Scoping Study Research Project on Google Bookmark Building Technologies Office: Small- and Medium-Sized Building Automation and Control System Needs: Scoping Study Research Project on Delicious Rank Building Technologies Office: Small- and Medium-Sized Building

16

New Services for Building Maintenance Enabled by Building Automation  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

New Services for Building Maintenance Enabled by Building Automation New Services for Building Maintenance Enabled by Building Automation Systems Speaker(s): Heikki Ihasalo Date: May 17, 2007 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Peng Xu Today's building automation systems enable building systems integration and access to information from a variety of sources, e.g. fire alarm systems, access control, security systems, lighting and control systems. With the help of Internet technology and XML (Extensible Markup Language) building automation systems can also connect to other enterprise\ applications such as facility management software, maintenance management systems, ERP or financial systems. New applications are also emerging to manage energy consumption in buildings, for example demand response and fault detection

17

Distributed Intelligent Automated Demand Response (DIADR) Building  

Broader source: Energy.gov (indexed) [DOE]

Distributed Intelligent Automated Demand Distributed Intelligent Automated Demand Response (DIADR) Building Management System Distributed Intelligent Automated Demand Response (DIADR) Building Management System The U.S. Department of Energy (DOE) is currently conducting research into distributed intelligent-automated demand response (DIADR) building management systems. Project Description This project aims to develop a DIADR building management system with intelligent optimization and control algorithms for demand management, taking into account a multitude of factors affecting cost including: Comfort Heating, ventilating, and air conditioning (HVAC) Lighting Other building systems Climate Usage and occupancy patterns. The key challenge is to provide the demand response the ability to address more and more complex building systems that include a variety of loads,

18

Participation through Automation: Fully Automated Critical Peak Pricing in Commercial Buildings  

E-Print Network [OSTI]

Figure 2. Demand Response Automation Server and BuildingII system to notify the Automation Server of an up comingoccurs day-ahead). 2. The Automation Server posts two pieces

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

2006-01-01T23:59:59.000Z

19

Sacks R. (1998), `Issues in the Development and Implementation of a Building Project Model for an Automated Building System', International Journal of Construction Information Technology, Salford University, Salford  

E-Print Network [OSTI]

designed to support computer-based integration between various construction applications, it is proposed of an Automated, Computer Integrated Building Realization System is to automatically generate all of the information required for the design, planning and execution of a building project. The project model forms

Sacks, Rafael

20

Concept for a Service-oriented Architecture in Building Automation Systems  

Science Journals Connector (OSTI)

Abstract On the consumer side exists great potential to use energy more efficiently. To exploit this potential, an intelligent control of building automation is required. The building automation market offers a variety of technologies, which do not rely on uniform standards. The programming effort for the appropriate implementation of identical functions in different locations is enormous and can be significantly reduced through a virtualization approach. In this way, real devices are represented by virtual devices that interact with stakeholders through business processes. To describe the business processes, workflows are used which consist of individual reusable and combinable services. These services were grouped into three categories. In addition to the room-/building-control-category, services are divided into metering/analysis/reporting-category and monitoring/configuration/user interface-category. The flexible combination and coordination of services must be supported. This is done by the use of a service- oriented architecture (SOA).

Tobias Teich; Sebastian Wolf; Tim Neumann; Sebastian Junghans; Susan Franke

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Building Automation and Controls Systems: Integrated Room Control for Personalized Comfort and Increased ROI  

E-Print Network [OSTI]

Smart Room Control ESL-IC-14-09-05 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Agenda ? Room Control fundamentals and evolution ? Challenges ? The Smart Room Control... approach ? Benefits ? Market applications ? Typical Configurations ? Summary ESL-IC-14-09-05 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14-17, 2014 Room Control – System Fundamentals ? HVAC...

Gill, D.

2014-01-01T23:59:59.000Z

22

Building the case for automated building energy management  

Science Journals Connector (OSTI)

Energy consumption in buildings comprises a significant fraction of total worldwide energy consumption and is strongly influenced by occupant behavior. To explore the quantitative effect of particular occupant actions on building energy consumption, ... Keywords: building automation, energy saving behaviors, in-home display

Alan Marchiori; Qi Han; William C. Navidi; Lieko Earle

2012-11-01T23:59:59.000Z

23

Experiences of Using Models and Information of Building Automation System in Commissioning  

E-Print Network [OSTI]

Simulation programs are widely used in the design of heating and cooling devices. However, modeling of the whole building with simulation programs is exceptional at least in Finland. We have built and utilized whole building models in a...

Keranen, H.; Kalema, T.; Pesonen, A.

2004-01-01T23:59:59.000Z

24

Building operating systems services: An architecture for programmable buildings.  

E-Print Network [OSTI]

architecture of an Automated Logic building managementAssociation. [24] Automated Logic Corporation. ALC systemarchitecture of an Automated Logic building management

Dawson-Haggerty, Stephen

2014-01-01T23:59:59.000Z

25

Home Automation System; Automation i hemmet.  

E-Print Network [OSTI]

?? This project revolves around creating a home automation system prototype with the main focus being the ability to lock/unlock a door through the internet.… (more)

Ruwaida,, Bassam

2013-01-01T23:59:59.000Z

26

Open Automated Demand Response for Small Commerical Buildings  

SciTech Connect (OSTI)

This report characterizes small commercial buildings by market segments, systems and end-uses; develops a framework for identifying demand response (DR) enabling technologies and communication means; and reports on the design and development of a low-cost OpenADR enabling technology that delivers demand reductions as a percentage of the total predicted building peak electric demand. The results show that small offices, restaurants and retail buildings are the major contributors making up over one third of the small commercial peak demand. The majority of the small commercial buildings in California are located in southern inland areas and the central valley. Single-zone packaged units with manual and programmable thermostat controls make up the majority of heating ventilation and air conditioning (HVAC) systems for small commercial buildings with less than 200 kW peak electric demand. Fluorescent tubes with magnetic ballast and manual controls dominate this customer group's lighting systems. There are various ways, each with its pros and cons for a particular application, to communicate with these systems and three methods to enable automated DR in small commercial buildings using the Open Automated Demand Response (or OpenADR) communications infrastructure. Development of DR strategies must consider building characteristics, such as weather sensitivity and load variability, as well as system design (i.e. under-sizing, under-lighting, over-sizing, etc). Finally, field tests show that requesting demand reductions as a percentage of the total building predicted peak electric demand is feasible using the OpenADR infrastructure.

Dudley, June Han; Piette, Mary Ann; Koch, Ed; Hennage, Dan

2009-05-01T23:59:59.000Z

27

A post-occupancy monitored evaluation of the dimmable lighting, automated shading, and underfloor air distribution system in The New York Times Building  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

23E 23E A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building E.S. Lee, L.L. Fernandes, B. Coffey, A. McNeil, R. Clear Lawrence Berkeley National Laboratory T. Webster, F. Bauman, D. Dickerhoff, D. Heinzerling, T. Hoyt University of California Berkeley Windows and Envelope Materials Group Building Technology and Urban Systems Department Environmental Energy Technologies Division January 2013 ! 2 Disclaimer This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any warranty,

28

Automated roller shades : Daylighting The New York Times Building  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Automated roller shades Automated roller shades Overview The architectural approach The owner's approach Daylighting field study Daylighting control systems Automated roller shades Procurement specifications Shades and Shade Controls Lighting Controls Visualizing daylight Commissioning/ verification Demand response Mainstream solutions Post-occupancy evaluation Publications Sponsors Project team Automated roller shades Automated roller shades manage daylight, solar heat gains, view, glare, privacy, and building appearance through changes in shade height. A roller shade consists of a fabric wrapped around a horizontal tube, which contains a tubular motor. The tubular motor rotates when ac- or dc- power is applied to it causing modulation in shade height. The control system can be designed to optimize numerous variables, the most common being control of direct sun. In this application, the shades were controlled to five preset heights that aligned with the architectural features of the façade - i.e., the vision portion of the window wall - so that direct sun penetrated no more than a specified distance from the window wall. The Times Company also requested that the shades control window glare, yet maximize the opportunity for view and daylight admission. Unnecessary up/down movement of the shade was to be minimized. Fabric choices (openness of the weave, color of the fabric facing toward the interior and exterior) were additional considerations in terms of appearance as well as visual comfort and daylighting benefits.

29

A Post-Occupancy Monitored Evaluation of the Dimmable Lighting, Automated Shading, and Underfloor Air Distribution System in The New York Times Building  

E-Print Network [OSTI]

with a sound, integrated building design, and then to paydesign, efficient technology and properly integrated buildingintegrated whole building systems Achieving a high level of building performance is the result of careful, informed design and execution so that building

2013-01-01T23:59:59.000Z

30

Automation Performance Index.  

E-Print Network [OSTI]

??Automation is intended to improve overall building performance. Building Automation Systems (BAS) are attractive and popular due to their promise of increased operational effectiveness. BAS… (more)

Makarechi, Shariar

2006-01-01T23:59:59.000Z

31

Building Technologies Office: Integrated Building Management System  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Integrated Building Integrated Building Management System Research Project to someone by E-mail Share Building Technologies Office: Integrated Building Management System Research Project on Facebook Tweet about Building Technologies Office: Integrated Building Management System Research Project on Twitter Bookmark Building Technologies Office: Integrated Building Management System Research Project on Google Bookmark Building Technologies Office: Integrated Building Management System Research Project on Delicious Rank Building Technologies Office: Integrated Building Management System Research Project on Digg Find More places to share Building Technologies Office: Integrated Building Management System Research Project on AddThis.com... About Take Action to Save Energy Partner with DOE

32

Occupancy-Driven Energy Management for Smart Building Automation  

E-Print Network [OSTI]

Occupancy-Driven Energy Management for Smart Building Automation Yuvraj Agarwal, Bharathan Balaji Buildings are among the largest consumers of electricity in the US. A significant portion of this energy use a building simulation framework and the occupancy information from our testbed, we show potential energy sav

Gupta, Rajesh

33

Automated Continuous Commissioning of Commercial Buildings  

E-Print Network [OSTI]

in building total energy consumption and related costs (overin building total energy consumption and related costs (overin building total energy consumption and related costs (over

Bailey, Trevor

2013-01-01T23:59:59.000Z

34

Using MDE to Build a Schizophrenic Middleware for Home/Building Automation  

E-Print Network [OSTI]

Using MDE to Build a Schizophrenic Middleware for Home/Building Automation Gr�egory Nain, Erwan presents an overview of EnTiMid, a middleware for home automation and presents the meta- model embedded Rennes Cedex Abstract. In the personal or corporate spheres, the home/office of tomor- row is soon

Paris-Sud XI, Université de

35

Building simulation approaches for the training of automated data analysis tools in building energy management  

Science Journals Connector (OSTI)

Abstract The field of building energy management, which monitors and analyses the energy use of buildings with the aim to control and reduce energy expenditure, is seeing a rapid evolution. Automated meter reading approaches, harvesting data at hourly or even half-hourly intervals, create a large pool of data which needs analysis. Computer analysis by means of machine learning techniques allows automated processing of this data, invoking expert analysis where anomalies are detected. However, machine learning always requires a historical dataset to train models and develop a benchmark to define what constitutes an anomaly. Computer analysis by means of building performance simulation employs physical principles to predict energy behaviour, and allows the assessment of the behaviour of buildings from a pure modelling background. This paper explores how building simulation approaches can be fused into energy management practice, especially with a view to the production of artificial bespoke benchmarks where historical profiles are not available. A real accommodation block, which is subject to monitoring, is used to gather an estimation of the accuracy of this approach. The findings show that machine learning from simulation models has a high internal accuracy; comparison with actual metering data shows prediction errors in the system (20%) but still achieves a substantial improvement over industry benchmark values.

Pieter de Wilde; Carlos Martinez-Ortiz; Darren Pearson; Ian Beynon; Martin Beck; Nigel Barlow

2013-01-01T23:59:59.000Z

36

Rockwell Automation & General Mills Teaming Profile | ENERGY STAR Buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Rockwell Automation & General Mills Teaming Profile Rockwell Automation & General Mills Teaming Profile Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources

37

Automate and accelerate build and release processes IBM Rational Build Forge  

E-Print Network [OSTI]

n n n n n n n Automate and accelerate build and release processes IBM Rational Build Forge in place today Accelerate build and release cycles through iterative develop- ment, parallel processes and efficient use of hardware Improve product quality through consistent, repeatable processes and early

38

Honeywell modular automation system acceptance test report  

SciTech Connect (OSTI)

This document provides the results of the Acceptance Test Procedure for the Honeywell Modular Automation System.

Cunningham, L.T., Westinghouse Hanford

1996-06-14T23:59:59.000Z

39

Building America System Research  

Broader source: Energy.gov (indexed) [DOE]

Building America System Building America System Research Eric Werling, DOE Ren Anderson, NREL eric.werling@ee.doe.gov, 202-586-0410 ren.anderson@nrel.gov, 303-384-7443 April 2, 2013 Building America System Innovations: Accelerating Innovation in Home Energy Savings 2 | Program Name or Ancillary Text eere.energy.gov Project Relevance 3 | Building Technologies Office eere.energy.gov Building America Fills Market Need for a High-Performance Homes HUB of Innovation

40

Energy Automation Systems Inc | Open Energy Information  

Open Energy Info (EERE)

Energy Automation Systems Inc Energy Automation Systems Inc Jump to: navigation, search Name Energy Automation Systems Inc. Place Hendersonville, Tennessee Zip 37075 Sector Buildings, Efficiency Product An energy efficiency consultancy firm focusing on analysis of energy consumption in buildings and providing improvments in the efficiency of the distribution system and equipment loads, similar to an ESCO. Coordinates 36.304861°, -86.620214° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":36.304861,"lon":-86.620214,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Automated Commissioning for Lower-cost, Widely Deployed Building Commissioning of the Future  

SciTech Connect (OSTI)

This chapter takes a brief look at the benefits of commissioning and describes a vision of the future where most of the objectives of commissioning will be accomplished automatically by capabilities built into the building systems themselves. Commissioning will become an activity that is performed continuously rather than periodically, and only repairs requiring replacement or overhaul of equipment will require manual intervention. This chapter then identifies some of the technologies that will be needed to realize this vision and ends with a call for all involved in the enterprise of building commissioning and automation to embrace and dedicate themselves to a future of automated commissioning.

Brambley, Michael R.; Katipamula, Srinivas

2011-08-16T23:59:59.000Z

42

Using Building Control System for Commissioning  

E-Print Network [OSTI]

France-USA Finland France Japan USA Netherlands Main End-Users BOp MC ES BD BOp BI BOp MC ES BOp BOw BS BOp ES BOp MC ES MI CA BOp MC ES BOp Type building Large commercial buildings Any types Medium and large commercial... 34, VTT, Finland, ISBN 951-38-5725-5. [4] Castro, N.S., Galler, M. A., Bushby, S. T. ?A Test Shell for Developing Automated Commissioning Tools for BACnet Systems? National Conference on Building Commissioning, 2003. ...

Vaezi-Nejad, H.; Salsbury, T.; Choiniere, D.

2004-01-01T23:59:59.000Z

43

One IBM Plant's Approach to Automated Control System Standards  

E-Print Network [OSTI]

ONE IBM PLANT'S APPROACH"TO AUTOMATED CONTROL SYSTEM STANDARDS John P. Cilia International Business Machines Corporation Poughkeepsie, New York ABSTRACT INSTRUMENTATION STANDARDS The trend toward lower cost of new technologies in building... Facilities Automation Control System (IPDFACS) standards used in the bidding process, the philosophy behind them, the type of instrumentation specified to be installed, and how to maintain this complex DDDC system. INTRODUCTION The lower cost of chips...

Cilia, J. P.

44

Automated Comparison of Building Energy Simulation Engines (Presentation)  

SciTech Connect (OSTI)

This presentation describes the BEopt comparative test suite, which is a tool that facilitates the automated comparison of building energy simulation engines. It also demonstrates how the test suite is improving the accuracy of building energy simulation programs. Building energy simulation programs inform energy efficient design for new homes and energy efficient upgrades for existing homes. Stakeholders rely on accurate predictions from simulation programs. Previous research indicates that software tends to over-predict energy usage for poorly-insulated leaky homes. NREL is identifying, investigating, and resolving software inaccuracy issues. Comparative software testing is one method of many that NREL uses to identify potential software issues.

Polly, B.; Horowitz, S.; Booten, B.; Kruis, N.; Christensen, C.

2012-08-01T23:59:59.000Z

45

AUTOMATED MODELING OF 3D BUILDING ROOFS USING IMAGE AND LIDAR DATA  

E-Print Network [OSTI]

AUTOMATED MODELING OF 3D BUILDING ROOFS USING IMAGE AND LIDAR DATA N. Demir* , E. Baltsavias, Detection, 3D Modelling ABSTRACT: In this work, an automated approach for 3D building roof modelling on the 3D building roof modelling. Buildings have a critical role for 3D city models, decision support

Schindler, Konrad

46

A DISTRIBUTED AUTOMATION SYSTEM FOR ELECTROPHYSICAL INSTALLATIONS  

E-Print Network [OSTI]

A DISTRIBUTED AUTOMATION SYSTEM FOR ELECTROPHYSICAL INSTALLATIONS V.R. Kozak Budker Institute There was designed a set of devices for automation systems of physical installations. On this basis approach. KEY WORDS Automation, systems, applications, CANBUS, embedded, controller. 1. Introduction Budker

Kozak, Victor R.

47

Automated Transportation Management System (ATMS)  

Broader source: Energy.gov (indexed) [DOE]

Re evised June 2010 Re evised June 2010 Autom The Depa Transport an integra system al outbound air. Its ea 1989 DOE significant operationa commerce electronic rates, pre transporta users eva shipments opportunit logistics im ATMS is i radioactiv shipments System ATMS is a activities p packaging including materials. common s lading, fre * W * C S * A * H * E * * O 0 mated T artment of Ene tation Manage ated web-base lowing users freight shipm arly developm E Inspector G t opportunitie al efficiency t e. Today's sy cally prepare s pare shipping ation bills befo aluate carrier s, and use co ties for system mprovements ts capability t ve and other h s in a comple Modules a modular sys performed by g and transpo radioactive a . Its modules shipment info eight bills, rate System Web Applic Carrier Eval Selection Automated

48

Java Automation Controller and Real-Time Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Java Automation Controller and Real-Time Systems Java Automation Controller and Real-Time Systems Speaker(s): Greg Bollella Date: June 29, 2009 - 12:00pm Location: 90-3122 Java has always been a disruptive technology and now it is breaking the mold in industrial, process, building, and transportation automation systems. For many years, programmable logic controllers (PLCs), the digital versions of old relay-based control systems (such as that used in the NYC Subway system in the late 1800s) have primarily controlled these systems. PLCs are the workhorses of the controls industry but the market is characterized by proprietary, closed, expensive, special-purpose solutions. A Java-based automation controller breaks the mold by allowing control algorithms, which require strict real-time capabilities, to run on

49

Microcomputer Applications in Power System Substation Automation  

Science Journals Connector (OSTI)

The object of this chapter is to describe power system applications of microcomputers, particularly in the area of power substation automation.The major functions required in substation automation are reviewed an...

C. T. Nguyen; R. Grondin; A. St-Jacques…

1983-01-01T23:59:59.000Z

50

Open Automated Demand Response for Small Commerical Buildings  

E-Print Network [OSTI]

of Fully Automated Demand  Response in Large Facilities.  Fully Automated Demand Response Tests in Large Facilities.  Open Automated  Demand Response Communication Standards: 

Dudley, June Han

2009-01-01T23:59:59.000Z

51

Automated Transportation Management System (ATMS) | Department...  

Office of Environmental Management (EM)

of Energy's (DOE's) Automated Transportation Management System is an integrated web-based logistics management system allowing users to manage inbound and outbound freight...

52

Open Automated Demand Response for Small Commerical Buildings  

E-Print Network [OSTI]

communications.    Automated Logic Model  Vendor  Load Type of the HVAC.   Automated Logic Model  Vendor  Load Type 

Dudley, June Han

2009-01-01T23:59:59.000Z

53

Atlas Sodium Automated Batch Synthesis System  

E-Print Network [OSTI]

Atlas Sodium Automated Batch Synthesis System (Syrris) June 2013 #12;Introduction to the system · The Atlas Sodium system consists of an Atlas base equipped with a 400ºC hotplate, a stacking dry bath systemL) for automated addition and/or removal of solution. · The system is computer controlled by the Atlas software

Subramanian, Venkat

54

Automated Surface Observing System: Standby Power Options  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Automated Automated Surface Observing System Standby Options Power Automated Surface Observing System (ASOS) General System Description * Self contained group of sensors and data gathering equipment that produces an automated weather observation * Weather observations support aviation, climate data, non government weather operations, public consumption, etc. * Initial deployment began in 1991 and continued through 1997 * Located at 884 sites nationwide, normally at airports * System has two distinct subsystems: Field installed equipment (DCP & Sensor Group) and an indoor processor (ACU) with peripherals * Separate facility power for DCP & Sensors and ACU 1 * measure and collect data * Located on the airport * back up group for 10 minutes * Currently pl

55

Automation Techniques for Intelligent Environments Prediction of Building Activity Patterns Using a Cyclic Genetic Algorithm  

E-Print Network [OSTI]

on the automation of these features and making the home a dynamic object that can better the comfort of its beneficial. Although the number of sensors in an average home and their uses in automation of simple tasksAutomation Techniques for Intelligent Environments Prediction of Building Activity Patterns Using

Parker, Gary B.

56

Trust in automated systems the effect of automation level on trust calibration .  

E-Print Network [OSTI]

??Automated systems perform functions that were previously executed by a human. When using automation, the role of the human changes from operator to supervisor. For… (more)

Walliser, James C.

2011-01-01T23:59:59.000Z

57

Preface: Cognitive Engineering in Automated Systems Design  

E-Print Network [OSTI]

Preface: Cognitive Engineering in Automated Systems Design This special issue was motivated by an apparent paucity of research on applications of cognitive engineering principles in the design of complex systems including mainte- nance, manufacturing, and transportation systems. Cognitive engineering

Kaber, David B.

58

Whole Building Ventilation Systems  

Broader source: Energy.gov (indexed) [DOE]

Whole-Building Whole-Building Ventilation Systems for Existing Homes © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved. Home Performance / Weatherization  Addressing ventilation is the exception  Max tightness, e.g. BPI's "Building Airflow Standard" (BAS)  References ASHRAE 62-89  BAS = Max [0.35 ACH, 15 CFM/person], CFM50 eq.  If BD tests show natural infiltration below BAS...  Ventilation must be recommended or installed.  SO DON'T AIR SEAL TO MUCH! © 2011 Steven Winter Associates, Inc. All rights reserved. © 2011 Steven Winter Associates, Inc. All rights reserved. Ventilation Requirements Ventilation systems for existing homes that are:

59

Building diagnosable distributed systems  

E-Print Network [OSTI]

Building diagnosable distributed systems Petros Maniatis Intel Research Berkeley ICSI ­ Security] Project response@R (R, K, SI) lookup response Specification #12;2/8/2006 Petros Maniatis9 Strawman Design Join lookup.NI == node.NI Join lookup.NI == succ.NI Select K in (N, S] Project response@R (R, K, SI

Maniatis, Petros

60

V-205: IBM Tivoli System Automation for Multiplatforms Java Multiple...  

Broader source: Energy.gov (indexed) [DOE]

5: IBM Tivoli System Automation for Multiplatforms Java Multiple Vulnerabilities V-205: IBM Tivoli System Automation for Multiplatforms Java Multiple Vulnerabilities July 29, 2013...

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

V-132: IBM Tivoli System Automation Application Manager Multiple...  

Energy Savers [EERE]

32: IBM Tivoli System Automation Application Manager Multiple Vulnerabilities V-132: IBM Tivoli System Automation Application Manager Multiple Vulnerabilities April 12, 2013 -...

62

Honeywell modular automation system computer software documentation  

SciTech Connect (OSTI)

This document provides a Computer Software Docuemntation for a new Honeywell Modular Automation System (MAS) being installed in the Plutonium Finishing Plant (PFP). This system will be used to control new thermal stabilization furnaces in HA-21I.

Cunningham, L.T.

1997-01-20T23:59:59.000Z

63

Automated Demand Response Strategies and Commissioning Commercial Building Controls  

E-Print Network [OSTI]

4 9 . Piette et at Automated Demand Response Strategies andDynamic Controls for Demand Response in New and ExistingFully Automated Demand Response Tests in Large Facilities"

Piette, Mary Ann; Watson, David; Motegi, Naoya; Kiliccote, Sila; Linkugel, Eric

2006-01-01T23:59:59.000Z

64

Making Automated Building Code Checking A Reality1 Charles S. Han, John Kunz, Kincho H. Law  

E-Print Network [OSTI]

in the September/October 1997 issue of Facility Management Journal 1 #12;2. A Building Model Standard In orderMaking Automated Building Code Checking A Reality1 Charles S. Han, John Kunz, Kincho H. Law Center set of building codes. The complexity and changing nature of codes leads to delays in both the design

Stanford University

65

The Center for Control, Dynamical Systems, and Computation University of California at Santa Barbara  

E-Print Network [OSTI]

inventory monitoring and control, home and building automation, power systems, security systems, precision monitoring, industrial automation, office and building automation, Supervisory Control and Data Acquisition

Akhmedov, Azer

66

LANL to certify automated influenza surveillance system  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

LANL to certify automated influenza surveillance system LANL to certify automated influenza surveillance system LANL to certify automated influenza surveillance system A compact automated system for surveillance and screening of potential pandemic strains of influenza and other deadly infectious diseases is a step closer to reality. January 31, 2011 Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy sources, to plasma physics and new materials. Los Alamos National Laboratory sits on top of a once-remote mesa in northern New Mexico with the Jemez mountains as a backdrop to research and innovation covering multi-disciplines from bioscience, sustainable energy

67

ZigBee Smart Home Automation Systems  

Science Journals Connector (OSTI)

This chapter summarizes a completed UK government funded project, the indeedNET ZigBee home automation system, which heralds a milestone in the ... energy saving devices with the potential to help home owners and...

Shuang-Hua Yang

2014-01-01T23:59:59.000Z

68

Automating the Selection of Fenestration Systems to Best Meet Daylighting  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Automating the Selection of Fenestration Systems to Best Meet Daylighting Automating the Selection of Fenestration Systems to Best Meet Daylighting Performance Goals Title Automating the Selection of Fenestration Systems to Best Meet Daylighting Performance Goals Publication Type Conference Paper LBNL Report Number LBNL-53003 Year of Publication 2003 Authors Fernandes, Luis L., and Konstantinos M. Papamichael Conference Name 2003 International Building Performance Simulation Association Conference Date Published 02/2003 Conference Location Eindhoven, Netherlands Call Number LBNL-53003 Abstract Traditional selection of fenestration systems follows a trial-and-error approach, i.e., iterative selection of fenestration systems and evaluation of their performance through the use of simulation tools and techniques. This paper is about the development of a new method, which inverts traditional practice, i.e., aims at automated selection of fenestration systems that best meet specific lighting performance goals. The new method is based on manipulation of matrices that represent the optical properties of fenestration systems, the propagation of light in interior spaces, and the outdoors luminous conditions. The method follows two steps: 1) the determination of the luminous flux distribution originating from the location of the fenestration that best meets the desired lighting performance goals and 2) the selection of the fenestration system that comes closer to producing the desired flux distribution from the outdoor daylight distribution.

69

Appropriate automation of rail signalling systems: a human factors study.  

E-Print Network [OSTI]

??This thesis examines the effect of automation in the rail signalling environment. The level of automation in a system can be described as ranging along… (more)

Balfe, Nora

2010-01-01T23:59:59.000Z

70

Wind resistance performance analysis of automated exterior wall painting robot for apartment buildings  

Science Journals Connector (OSTI)

Painters who have to work on the exterior walls of high-rise buildings are constantly exposed to the risk of falling, which can be fatal. Korea and other countries are endeavoring to develop technology that autom...

Ji-Won Cho; Hyun-Seok Yoo; Seung-Ho Choi…

2014-10-01T23:59:59.000Z

71

Building Technologies Office: Building-Level Energy Management Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Building-Level Energy Building-Level Energy Management Systems Research Project to someone by E-mail Share Building Technologies Office: Building-Level Energy Management Systems Research Project on Facebook Tweet about Building Technologies Office: Building-Level Energy Management Systems Research Project on Twitter Bookmark Building Technologies Office: Building-Level Energy Management Systems Research Project on Google Bookmark Building Technologies Office: Building-Level Energy Management Systems Research Project on Delicious Rank Building Technologies Office: Building-Level Energy Management Systems Research Project on Digg Find More places to share Building Technologies Office: Building-Level Energy Management Systems Research Project on AddThis.com... About Take Action to Save Energy

72

ALMS: Automated logic mapping system  

Science Journals Connector (OSTI)

ALMS is a set of design automation computer programs which accepts as input a description of a logic design, specifications of modules (e.g., chips, cards, etc.) into which the blocks of the design are to be partitioned or mapped, and some constraints ...

R. L. Russo; P. K. Wolff, Sr.

1971-06-01T23:59:59.000Z

73

Safe controllers design for industrial automation systems  

Science Journals Connector (OSTI)

The design of safe industrial controllers is one of the most important domains related to Automation Systems research. To support it, synthesis and analysis techniques are available. Among the analysis techniques, two of the most important are Simulation ... Keywords: Formal verification, Industrial systems behaviour modelling, Real-time systems, Safe controllers, Simulation

José Machado; Eurico Seabra; José C. Campos; Filomena Soares; Celina P. Leão

2011-05-01T23:59:59.000Z

74

European Union Energy Performance of Building Directive and the Impact of Building Automation on Energy Efficiency  

E-Print Network [OSTI]

consumption. The European Union's 2002 Energy Performance of Buildings Directive takes this fact into account and formulates savings goals. A resulting European standard, and uniform certification, applicable throughout Europe, form the foundation since... to standardized utilization of the building?. The energy consumers concerned are heating, water heating, cooling, ventilating and lighting; also included is the auxiliary electric power require to operate these systems. One of the basic requirements of the EPBD...

Wirth, U.

2008-01-01T23:59:59.000Z

75

Building Technology and Urban Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Office building exterior and infrared thermograph Office building exterior and infrared thermograph Building Technology and Urban Systems Building Technology and Urban Systems application/pdf icon btus-org-chart-03-2013.pdf In the areas of Building Technology and Urban Systems, EETD researchers conduct R&D and develop physical and information technologies to make buildings and urban areas more energy- and resource-efficient. These technologies create jobs and products for the marketplace in clean technology industries. They improve quality of life, and reduce the emissions of pollutants, including climate-altering greenhouse gases. BTUSD's goal is to provide the technologies needed to operate buildings at 50 to 70 percent less energy use than average today. BTUS develops, demonstrates and deploys: Information technologies for the real-time monitoring and control of

76

Honeywell Modular Automation System Computer Software Documentation  

SciTech Connect (OSTI)

This document provides a Computer Software Documentation for a new Honeywell Modular Automation System (MAS) being installed in the Plutonium Finishing Plant (PFP). This system will be used to control new thermal stabilization furnaces in HA-211 and vertical denitration calciner in HC-230C-2.

CUNNINGHAM, L.T.

1999-09-27T23:59:59.000Z

77

Building Design Advisor: Automated integration of multiple simulation tools K. Papamichael, J. LaPorta, H. Chauvet  

E-Print Network [OSTI]

LBNL-40591 Preprint Building Design Advisor: Automated integration of multiple simulation tools K Design Advisor (BDA) is a software environment that supports the integrated use of multiple analysis

78

Energy Department Issues Green Building Certification System...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Department Issues Green Building Certification System Final Rule to Support Increased Energy Measurement and Efficient Building Design Energy Department Issues Green Building...

79

Energy Department Issues Green Building Certification System...  

Broader source: Energy.gov (indexed) [DOE]

Issues Green Building Certification System Final Rule to Support Increased Energy Measurement and Efficient Building Design Energy Department Issues Green Building Certification...

80

An Extended Process Automation System: An Approach Based on a Multi-Agent System.  

E-Print Network [OSTI]

??This thesis describes studies on application of multi-agent systems (acronym: MAS) to enhance process automation systems. A specification of an extended process automation system is… (more)

Seilonen, Ilkka

2006-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

An extended process automation system : an approach based on a multi-agent system.  

E-Print Network [OSTI]

??This thesis describes studies on application of multi-agent systems (acronym: MAS) to enhance process automation systems. A specification of an extended process automation system is… (more)

Seilonen, Ilkka

2006-01-01T23:59:59.000Z

82

Automated Fuel Dispensing System Form Instructions  

E-Print Network [OSTI]

Automated Fuel Dispensing System Form Instructions If additional forms are necessary to provide(s) are hired and will be obtaining fuel, an Add Driver Form MUST be submitted for entry into the web database and/or diesel fuel to operate. Note: When a new vehicle, golf cart (gasoline), etc., is placed

Fernandez, Eduardo

83

Classified Automated Information System Security Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

To establish uniform requirements, policies, responsibilities, and procedures for the development and implementation of a Department of Energy (DOE) Classified Computer Security Program to ensure the security of classified information in automated data processing (ADP) systems. Cancels DOE O 5637.1. Canceled by DOE O 471.2.

1994-07-15T23:59:59.000Z

84

Acoustic Building Infiltration Measurement System (ABIMS)  

Broader source: Energy.gov [DOE]

The Acoustic Building Infilitration Measurement System project is developing an acoustic method of measuring the infiltration of a building envelope.

85

Webinar: Make Your Building Sing!: Building-Retuning to Reduce...  

Broader source: Energy.gov (indexed) [DOE]

(PNNL) developed a curricula focused on retuning both large (with a building automation system, or BAS) and small (without a BAS) commercial buildings. Hear from Better...

86

Salsbury and Diamond: Automated Testing of HVAC Systems for Commissioning -1 -Automated Testing of HVAC Systems for Commissioning  

E-Print Network [OSTI]

and Diamond: Automated Testing of HVAC Systems for Commissioning - 1 - Automated Testing of HVAC Systems This paper describes an approach to the automation of the commissioning of HVAC systems. The approach of many HVAC systems is limited more by poor installation, commissioning, and maintenance than by poor

87

Exploiting Home Automation Protocols for Load Monitoring in Smart Buildings  

E-Print Network [OSTI]

load con- sumes, e.g., to enable automated demand response. Al- though load monitoring and control, Sean Barker, Aditya Mishra, Prashant Shenoy, and Jeannie Albrecht University of Massachusetts Amherst@cs.williams.edu Abstract Monitoring and controlling electrical loads is crucial for demand-side energy management in smart

Massachusetts at Amherst, University of

88

Techniques for Securing Substation Automation Systems David Guidry1  

E-Print Network [OSTI]

Techniques for Securing Substation Automation Systems David Guidry1 , Mike Burmester1 , Xiuwen Liu1 propose techniques for resilient substation automation of power utility systems with security based-90-5 compliant substation automation systems that are resilient. We demonstrate the feasibility of our approach

Burmester, Mike

89

Remote-Controlled Home Automation Systems with Different Network Technologies  

E-Print Network [OSTI]

Remote-Controlled Home Automation Systems with Different Network Technologies Armando Roy Delgado into the potential for remote controlled operation of home automation systems. It considers problems, 2002) which certainly requires a careful study before developing any suitable Home Automation System

Grout, Vic

90

Building a Smarter Distribution System in Pennsylvania  

Broader source: Energy.gov (indexed) [DOE]

Study - PPL Electric Utilities Corporation Smart Grid Investment Grant Study - PPL Electric Utilities Corporation Smart Grid Investment Grant 1 Building a Smarter Distribution System in Pennsylvania PPL Electric Utilities Corporation (PPL) provides electricity to 1.4 million customers across central and eastern Pennsylvania. Having installed smart meters and other advanced technologies over the last several years, PPL has experience with operating smart grid systems and achieving operational improvements. To further improve quality of service for its customers, PPL is implementing a $38 million Smart Grid Investment Grant, which includes $19 million in Recovery Act funds from the U.S. Department of Energy (DOE). PPL is installing a distribution management system (DMS), distribution automation (DA) devices, and supporting communication systems in a pilot program in the Harrisburg

91

Findings from Seven Years of Field Performance Data for Automated Demand Response in Commercial Buildings  

SciTech Connect (OSTI)

California is a leader in automating demand response (DR) to promote low-cost, consistent, and predictable electric grid management tools. Over 250 commercial and industrial facilities in California participate in fully-automated programs providing over 60 MW of peak DR savings. This paper presents a summary of Open Automated DR (OpenADR) implementation by each of the investor-owned utilities in California. It provides a summary of participation, DR strategies and incentives. Commercial buildings can reduce peak demand from 5 to 15percent with an average of 13percent. Industrial facilities shed much higher loads. For buildings with multi-year savings we evaluate their load variability and shed variability. We provide a summary of control strategies deployed, along with costs to install automation. We report on how the electric DR control strategies perform over many years of events. We benchmark the peak demand of this sample of buildings against their past baselines to understand the differences in building performance over the years. This is done with peak demand intensities and load factors. The paper also describes the importance of these data in helping to understand possible techniques to reach net zero energy using peak day dynamic control capabilities in commercial buildings. We present an example in which the electric load shape changed as a result of a lighting retrofit.

Kiliccote, Sila; Piette, Mary Ann; Mathieu, Johanna; Parrish, Kristen

2010-05-14T23:59:59.000Z

92

Development of Building Automation and Control Systems  

E-Print Network [OSTI]

www. automatedlogic.com. [3] Modelica. [Online]. Available:as Simulink [4] and Modelica [3]Vand the available back-enduser input (e.g. , Simulink and Modelica), and to the output

Yang, Yang; Zhu, Qi; Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

93

Enhancing Building Operations Through Automated Diagnostics: Field Test Results  

E-Print Network [OSTI]

. Details of Field Test Sites Location Building Type Number of AHU Type of AHU Typical Schedule (military time) Richland Office/Lab 6 VAV 0 to 24 Richland Office 3 CAV 6 to 18 Denver Office 3 VAV 0 to 24 San Francisco Hotel 6.... Pratt, R.G., N.N. Bauman, and S. Katipamula. 2003. ?New Technology Demonstration of the Whole-Building Diagnostician at the Federal Aviation Administration-Denver Airport.? PNNL- 14157, Pacific Northwest National Laboratory, Richland, Washington...

Katipamula, S.; Brambley, M. R.; Bauman, N.; Pratt, R. G.

2003-01-01T23:59:59.000Z

94

Installation and Commissioning Automated Demand Response Systems  

E-Print Network [OSTI]

their partnership in demand response automation research andand Techniques for Demand Response. LBNL Report 59975. Mayof Fully Automated Demand Response in Large Facilities.

Kiliccote, Sila; Global Energy Partners; Pacific Gas and Electric Company

2008-01-01T23:59:59.000Z

95

National System Templates: Building Sustainable National Inventory...  

Open Energy Info (EERE)

Templates: Building Sustainable National Inventory Management Systems Jump to: navigation, search Tool Summary LAUNCH TOOL Name: National System Templates: Building Sustainable...

96

Building Technologies Office: Energy Systems Innovations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Systems Energy Systems Innovations to someone by E-mail Share Building Technologies Office: Energy Systems Innovations on Facebook Tweet about Building Technologies Office: Energy Systems Innovations on Twitter Bookmark Building Technologies Office: Energy Systems Innovations on Google Bookmark Building Technologies Office: Energy Systems Innovations on Delicious Rank Building Technologies Office: Energy Systems Innovations on Digg Find More places to share Building Technologies Office: Energy Systems Innovations on AddThis.com... About Take Action to Save Energy Partner With DOE Activities Solar Decathlon Building America Research Innovations Research Tools Building Science Education Climate-Specific Guidance Solution Center Partnerships Meetings Publications Home Energy Score

97

ATLAS Nightly Build System Upgrade  

E-Print Network [OSTI]

The ATLAS Nightly Build System is a facility for automatic production of software releases. Being the major component of ATLAS software infrastructure, it supports more than 50 multi-platform branches of nightly releases and provides ample opportunities for testing new packages, for verifying patches to existing software, and for migrating to new platforms and compilers. The Nightly System testing framework runs several hundred integration tests of different granularity and purpose. The nightly releases are distributed and validated, and some are transformed into stable releases used for data processing worldwide. The first LHC long shutdown (2013-2015) activities will elicit increased load on the Nightly System as additional releases and builds are needed to exploit new programming techniques, languages, and profiling tools. This paper describes the plan of the ATLAS Nightly Build System Long Shutdown upgrade. It brings modern database and web technologies into the Nightly System, improves monitoring of nigh...

Dimitrov, G; The ATLAS collaboration; Simmons, B; Undrus, A

2013-01-01T23:59:59.000Z

98

n-Tiered Test Automation Architecture for Agile Software Systems  

Science Journals Connector (OSTI)

Abstract This paper introduces a multi-tiered test automation architecture to optimize test automation in an Agile software development environment while increasing both the test coverage and depth of each tier. Test Automation is the act of converting manual test cases into automated scripts that can be executed autonomously. In general, testing accounts for roughly 60% of the overall development budget and approximately 50% of that is attributed to regression testing. In recent years software organizations have begun migrating to Agile software development practices and automated testing in hopes of reducing the cost, lengthy regression cycles, and time to market. Traditionally, test automation is conducted on stable, non-changing applications. In an Agile environment where the code constantly changes, automated test cases become obsolete and must constantly be refactored in order to provide meaningful feedback about the system's quality. In most instances the cost of maintenance of automated test code completely overshadows the entire automation effort and negates any possible Return on Investment (RoI). An n-Tiered Test Automation Architecture seeks to retain the RoI by abstracting the automation project into separate distinct tiers; Presentation, Business, Data, and Services. These abstractions allow automated testing to continue providing feedback despite the constant revision of the system. A case study was conducted using this method and the observations showed that the automation architecture was resilient to change while increasing the test coverage, the depth of testing, and the overall quality of the application under test.

Patrick Day

2014-01-01T23:59:59.000Z

99

Variability in Automated Responses of Commercial Buildings and Industrial  

E-Print Network [OSTI]

consumption of commercial buildings and industrial facilities (C&I facilities) during Demand Response (DR. Keywords: demand response, baseline models, load prediction, error analysis, variability, measurement in the past ­ either with relays that interrupt power to air conditioners and water heaters [1], [2

100

Honeywell Modular Automation System Computer Software Documentation  

SciTech Connect (OSTI)

The purpose of this Computer Software Document (CSWD) is to provide configuration control of the Honeywell Modular Automation System (MAS) in use at the Plutonium Finishing Plant (PFP). This CSWD describes hardware and PFP developed software for control of stabilization furnaces. The Honeywell software can generate configuration reports for the developed control software. These reports are described in the following section and are attached as addendum's. This plan applies to PFP Engineering Manager, Thermal Stabilization Cognizant Engineers, and the Shift Technical Advisors responsible for the Honeywell MAS software/hardware and administration of the Honeywell System.

STUBBS, A.M.

2000-12-04T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

V-132: IBM Tivoli System Automation Application Manager Multiple  

Broader source: Energy.gov (indexed) [DOE]

2: IBM Tivoli System Automation Application Manager Multiple 2: IBM Tivoli System Automation Application Manager Multiple Vulnerabilities V-132: IBM Tivoli System Automation Application Manager Multiple Vulnerabilities April 12, 2013 - 6:00am Addthis PROBLEM: IBM has acknowledged multiple vulnerabilities in IBM Tivoli System Automation Application Manager PLATFORM: The vulnerabilities are reported in IBM Tivoli System Automation Application Manager versions 3.1, 3.2, 3.2.1, and 3.2.2 ABSTRACT: Multiple security vulnerabilities exist in the IBM Java Runtime Environment component of IBM Tivoli System Automation Application Manager which may affect the product REFERENCE LINKS: Secunia Advisory: SA53006 IBM Security Bulletin 21633991 IBM Security Bulletin 21633992 CVE-2011-3563 CVE-2012-0497 CVE-2012-0498 CVE-2012-0499 CVE-2012-0501

102

V-132: IBM Tivoli System Automation Application Manager Multiple  

Broader source: Energy.gov (indexed) [DOE]

2: IBM Tivoli System Automation Application Manager Multiple 2: IBM Tivoli System Automation Application Manager Multiple Vulnerabilities V-132: IBM Tivoli System Automation Application Manager Multiple Vulnerabilities April 12, 2013 - 6:00am Addthis PROBLEM: IBM has acknowledged multiple vulnerabilities in IBM Tivoli System Automation Application Manager PLATFORM: The vulnerabilities are reported in IBM Tivoli System Automation Application Manager versions 3.1, 3.2, 3.2.1, and 3.2.2 ABSTRACT: Multiple security vulnerabilities exist in the IBM Java Runtime Environment component of IBM Tivoli System Automation Application Manager which may affect the product REFERENCE LINKS: Secunia Advisory: SA53006 IBM Security Bulletin 21633991 IBM Security Bulletin 21633992 CVE-2011-3563 CVE-2012-0497 CVE-2012-0498 CVE-2012-0499 CVE-2012-0501

103

An automated vacuum gauge calibration system  

SciTech Connect (OSTI)

An automated system for calibrating vacuum gauges over the pressure range of 10{sup {minus}6} to 0.1 Pa was designed and constructed at the National Institute of Standards and Technology (NIST) for the Department of Energy (DOE) Primary Standards Laboratory at Sandia National Laboratories (SNL). Calculable pressures are generated by passing a known flow of gas through an orifice of known conductance. The orifice conductance is derived from dimensional measurements and accurate flows are generated using metal capillary leaks. The expanded uncertainty (k = 2) in the generated pressure is estimated to be between 1% and 4% over the calibration range. The design, calibration results. and component uncertainties will be discussed.

Abbott, P.J. [NIST, GAithersburg, MD (United States); Benner, M.S. [Sandia National Labs., Albuquerque, NM (United States)

1998-04-01T23:59:59.000Z

104

Automated macromolecular crystal detection system and method  

DOE Patents [OSTI]

An automated macromolecular method and system for detecting crystals in two-dimensional images, such as light microscopy images obtained from an array of crystallization screens. Edges are detected from the images by identifying local maxima of a phase congruency-based function associated with each image. The detected edges are segmented into discrete line segments, which are subsequently geometrically evaluated with respect to each other to identify any crystal-like qualities such as, for example, parallel lines, facing each other, similarity in length, and relative proximity. And from the evaluation a determination is made as to whether crystals are present in each image.

Christian, Allen T. (Tracy, CA); Segelke, Brent (San Ramon, CA); Rupp, Bernard (Livermore, CA); Toppani, Dominique (Fontainebleau, FR)

2007-06-05T23:59:59.000Z

105

INTEGRATED ENERGY SYSTEMS: PRODUCTIVITY & BUILDING SCIENCE  

E-Print Network [OSTI]

Integrated Design of Commercial Building Ceiling Systems Integrated Design of Residential Ducting & Air FlowINTEGRATED ENERGY SYSTEMS: PRODUCTIVITY & BUILDING SCIENCE Productivity and Interior Environments Integrated Design of Large Commercial HVAC Systems Integrated Design of Small Commercial HVAC Systems

106

Reference Model for Control and Automation Systems in Electrical Power |  

Broader source: Energy.gov (indexed) [DOE]

Model for Control and Automation Systems in Electrical Model for Control and Automation Systems in Electrical Power Reference Model for Control and Automation Systems in Electrical Power Modern infrastructure automation systems are threatened by cyber attack. Their higher visibility in recent years and the increasing use of modern information technology (IT) components contribute to increased security risk. A means of analyzing these infrastructure automation systems is needed to help understand and study the many system relationships that affect the overall security of the system. Modeling these systems is a very cost effective means of addressing the problem of security from an overall system view. The model presented in the document below provides a structured, cost effective approach to address technical security in process control systems

107

Automated Office Systems Support (AOSS) Quality Assurance Model...  

Broader source: Energy.gov (indexed) [DOE]

assurance model, including checklists, for activity relative to network and desktop computer support. Automated Office Systems Support (AOSS) Quality Assurance Model More...

108

Substation automation systems and IEC 61850: interoperability testing.  

E-Print Network [OSTI]

??Dissertação de mest., Engenharia Electrónica e Telecomunicações, Faculdade de Ciências e Tecnologia, Univ. do Algarve, 2011 The Substation Automation System (SAS) is the backbone of… (more)

Evaristo, Henrique A. Guerreiro Dias

2011-01-01T23:59:59.000Z

109

An automated testing system for telephony software - A case study.  

E-Print Network [OSTI]

??As the complexity of software system increases, delivering quality software successfully becomes an ever more challenging task. Applying automated testing techniques effectively to the software… (more)

Zhou, Yingxiang Ingrid

2009-01-01T23:59:59.000Z

110

Integrated Building Energy Systems Design Considering Storage Technologies  

E-Print Network [OSTI]

L ABORATORY Integrated Building Energy Systems Design7301 Integrated building energy systems design considering

Stadler, Michael

2009-01-01T23:59:59.000Z

111

Building systems optimization controls calibration  

SciTech Connect (OSTI)

During the period between May 9, 1994 and June 2, 1994, Engineered Facility Management (EFM) conducted a comprehensive investigation into the condition and operation of the equipment and systems at a major high-rise building owned by a large California bank. The goal of the project was to improve the project`s energy cost per square foot without major system retrofit and capital expenditure. This report is a compilation of the findings, actions taken and recommendations.

NONE

1995-02-01T23:59:59.000Z

112

Automated two column generator systems for medical radionuclides  

Science Journals Connector (OSTI)

This work describes automated chromatographic methods for the separation of medically useful radionuclides from source material containing their parent radionuclides. The separation techniques employ two chromatographic columns to ensure high chemical and radiochemical purity of the product radionuclide. The separations were performed using an automated system, the automated radionuclide separator (ARS2), consisting of syringe pumps and multiport valves controlled through a computer interface. Generator systems for 68Ga, 99mTc, 188Re and 213Bi will be described.

Daniel R. McAlister; E. Philip Horwitz

2009-01-01T23:59:59.000Z

113

Open Automated Demand Response for Small Commerical Buildings  

E-Print Network [OSTI]

Power Systems) Cannon & Honeywell together for smart rd  party vendors such as  Honeywell.   Mostly a remote web of wireless  connections.   Honeywell Honeywell has many

Dudley, June Han

2009-01-01T23:59:59.000Z

114

Green Building Certification Systems Requirement for New Federal...  

Broader source: Energy.gov (indexed) [DOE]

Green Building Certification Systems Requirement for New Federal Buildings and Major Renovations of Federal Buildings Final Rule Green Building Certification Systems Requirement...

115

National System Templates: Building Sustainable National Inventory  

Open Energy Info (EERE)

National System Templates: Building Sustainable National Inventory National System Templates: Building Sustainable National Inventory Management Systems Jump to: navigation, search Tool Summary LAUNCH TOOL Name: National System Templates: Building Sustainable National Inventory Management Systems Agency/Company /Organization: United States Environmental Protection Agency, United States Agency for International Development Sector: Energy, Land Focus Area: Non-renewable Energy, Forestry, Agriculture Topics: GHG inventory Resource Type: Guide/manual, Training materials Website: www.epa.gov/climatechange/emissions/ghginventorycapacitybuilding/templ National System Templates: Building Sustainable National Inventory Management Systems Screenshot References: National System Templates: Building Sustainable National Inventory Management Systems[1]

116

Generic planning and control of automated material handling systems  

Science Journals Connector (OSTI)

This paper discusses the problem to design a generic planning and control architecture for automated material handling systems (AMHSs). We illustrate the relevance of this research direction, and then address three different market sectors where AMHSs ... Keywords: Automated material handling systems, Generic control architecture, Real-time scheduling

S. W. A. Haneyah; J. M. J. Schutten; P. C. Schuur; W. H. M. Zijm

2013-04-01T23:59:59.000Z

117

Honeywell modular automation system computer software documentation  

SciTech Connect (OSTI)

The purpose of this Computer Software Document (CSWD) is to provide configuration control of the Honeywell Modular Automation System (MAS) in use at the Plutonium Finishing Plant (PFP). The Honeywell MAS is used to control the thermal stabilization furnaces in glovebox HA-211. The PFP developed software is being updated to reflect the Polycube Processing and Unwashed Salt Thermal Stabilization program addition. The polycube processing program was installed per HNF-FMP-02-11162-R2. The functional test of the program was performed in JCS work package 22-02-1031, The unwashed salt item program was installed per HNF-FMP-03-16577-RO. The functional test of the program completed in JCS work package 22-03-00654.

STUBBS, A.M.

2003-07-02T23:59:59.000Z

118

Honeywell Modular Automation System Acceptance Test Procedure  

SciTech Connect (OSTI)

The purpose of this Acceptance Test Procedure (ATP) is to verify the operability of the three new furnaces as controlled by the new Honeywell Modular Automation System (MAS). The Honeywell MAS is being installed in PFP to control the three thermal stabilization furnaces in glovebox HA-211. The ATP provides instructions for testing the configuration of the Honeywell MAS at the Plutonium Finishing Plant(PFP). The test will be a field test of the analog inputs, analog outputs, and software interlocks. The interlock test will check the digital input and outputs. Field equipment will not be connected forth is test. Simulated signals will be used to test thermocouple, limit switch, and vacuum pump inputs to the PLUMAS.

STUBBS, A.M.

1999-09-21T23:59:59.000Z

119

Automated interferometric alignment system for paraboloidal mirrors  

DOE Patents [OSTI]

A method is described for a systematic method of interpreting interference fringes obtained by using a corner cube retroreflector as an alignment aid when aigning a paraboloid to a spherical wavefront. This is applicable to any general case where such alignment is required, but is specifically applicable in the case of aligning an autocollimating test using a diverging beam wavefront. In addition, the method provides information which can be systematically interpreted such that independent information about pitch, yaw and focus errors can be obtained. Thus, the system lends itself readily to automation. Finally, although the method is developed specifically for paraboloids, it can be seen to be applicable to a variety of other aspheric optics when applied in combination with a wavefront corrector that produces a wavefront which, when reflected from the correctly aligned aspheric surface will produce a collimated wavefront like that obtained from the paraboloid when it is correctly aligned to a spherical wavefront.

Maxey, L. Curtis (Powell, TN)

1993-01-01T23:59:59.000Z

120

Automated interferometric alignment system for paraboloidal mirrors  

DOE Patents [OSTI]

A method is described for a systematic method of interpreting interference fringes obtained by using a corner cube retroreflector as an alignment aid when aligning a paraboloid to a spherical wavefront. This is applicable to any general case where such alignment is required, but is specifically applicable in the case of aligning an autocollimating test using a diverging beam wavefront. In addition, the method provides information which can be systematically interpreted such that independent information about pitch, yaw and focus errors can be obtained. Thus, the system lends itself readily to automation. Finally, although the method is developed specifically for paraboloids, it can be seen to be applicable to a variety of other aspheric optics when applied in combination with a wavefront corrector that produces a wavefront which, when reflected from the correctly aligned aspheric surface will produce a collimated wavefront like that obtained from the paraboloid when it is correctly aligned to a spherical wavefront. 14 figures.

Maxey, L.C.

1993-09-28T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

E-Print Network 3.0 - automated systems based Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

automation and human tasks in complex systems. The methodology will be based on formal modeling, simulation... design of complex systems, including design of the automation and...

122

E-Print Network 3.0 - automated test system Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Powered by Explorit Topic List Advanced Search Sample search results for: automated test system Page: << < 1 2 3 4 5 > >> 1 Automated Software System Analysis and Testing...

123

E-Print Network 3.0 - automated paging system Sample Search Results  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

which ensue. In an adaptive system, by contrast, the flexibility in information or automation behavior... and performance automation subsystems in an adaptive system, but which...

124

Design and Fabrication of Security and Home Automation System  

Science Journals Connector (OSTI)

Home automation system was designed and fabricated for controlling of home appliances, gas detection and home security. The fabricated system could detect the ... the house or office and the operation of home app...

Eung Soo Kim; Min Sung Kim

2006-01-01T23:59:59.000Z

125

Intelligent Building Energy Information and Control Systems for Low-Energy Operations and Optimal Demand Response  

E-Print Network [OSTI]

Open  Automated  Demand  Response  Communications from  7 Years of Automated Demand Response in Commercial Management and Demand Response in Commercial  Buildings. , 

Piette, Mary Ann

2014-01-01T23:59:59.000Z

126

A robust automated system elucidates mouse home cage behavioral structure  

E-Print Network [OSTI]

A robust automated system elucidates mouse home cage behavioral structure Evan H. Gouldinga,1 , A of behavior exhibited by mice in their home cages reflect the function and interaction of numerous behavioral of organization across diverse behaviors has been difficult to achieve and automate. Here, we describe

Jiggins, Francis

127

Automation of Calibration System for Dark Energy Survey  

E-Print Network [OSTI]

Automation of Calibration System for Dark Energy Survey Jason Wise1, J. P. Rheault1, D. L. DePoy1 1 from gravitational interactions. The Dark Energy Survey (DES) is a sky survey designed to find. Abstract DECalS is a fully automated remote control program for the Dark Energy Survey spectrophotometric

128

Green Building Certification Systems Requirement for New Federal Buildings and Major Renovations of Federal Buildings Final Rule  

Broader source: Energy.gov [DOE]

Document details the Green Building Certification Systems Requirement for New Federal Buildings and Major Renovations of Federal Buildings' Final Rule for 10 CFR Parts 433, 435 and 436.

129

Home | Buildings Technology & Urban Systems Department  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Lab Buildings & Urban Systems Buildings Lab Buildings & Urban Systems Buildings Technology & Urban Systems Department Search Search Home About Us Groups Tools & Guides Facilities Publications News Links Contact Us Staff The Building Technology and Urban Systems Department (BTUS) works closely with industry to develop technologies for buildings that increase energy efficiency, and improve the comfort, health, and safety of building occupants. Berkeley Lab Hosts 5 Emerging Leaders During TechWomen 2013 As part of TechWomen 2013, emerging leaders from around the world toured a number of scientific facilities in the Bay Area, including the Advanced Light Source at Berkeley Lab. Pho Read More The Retrocommissioning Sensor Suitcase Brings Energy Efficiency to Small Commercial Buildings The data module communicates wirelessly with the smart pad, which launches

130

V-205: IBM Tivoli System Automation for Multiplatforms Java Multiple  

Broader source: Energy.gov (indexed) [DOE]

V-205: IBM Tivoli System Automation for Multiplatforms Java V-205: IBM Tivoli System Automation for Multiplatforms Java Multiple Vulnerabilities V-205: IBM Tivoli System Automation for Multiplatforms Java Multiple Vulnerabilities July 29, 2013 - 4:20am Addthis PROBLEM: IBM has acknowledged a weakness and multiple vulnerabilities in IBM Tivoli System Automation for Multiplatforms, which can be exploited by malicious, local users to disclose certain sensitive information and gain escalated privileges and by malicious people to disclose certain sensitive information, manipulate certain data, bypass certain security restrictions, cause a DoS (Denial of Service), and compromise a vulnerable system. PLATFORM: The weakness and the vulnerabilities are reported in versions 3.1 through 3.2.2 running on AIX, Linux, Solaris, and Windows.

131

Findings from Seven Years of Field Performance Data for Automated Demand Response in Commercial Buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

3E 3E Findings from Seven Years of Field Performance Data for Automated Demand Response in Commercial Buildings S. Kiliccote, M.A. Piette, J. Mathieu, K. Parrish Environmental Energy Technologies Division May 2010 Presented at the 2010 ACEEE Summer Study on Energy Efficiency in Buildings, Pacific Grove, CA, August 15-20, 2010, and published in the Proceedings DISCLAIMER This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or usefulness of any information,

132

Transforming Commercial Building Operations  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Transforming Commercial Building Operations Transforming Commercial Building Operations Transforming Commercial Building Operations Ron Underhill Pacific Northwest National Laboratory ronald.underhill@pnnl.gov (509)375-9765 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Most buildings are not commissioned (Cx) before occupancy, including HVAC and lighting systems * Buildings often are poorly operated and maintained leading to significant energy waste of 5 to 20%, even when they have building automation systems (BASs)

133

Transforming Commercial Building Operations  

Broader source: Energy.gov (indexed) [DOE]

Transforming Commercial Building Operations Transforming Commercial Building Operations Transforming Commercial Building Operations Ron Underhill Pacific Northwest National Laboratory ronald.underhill@pnnl.gov (509)375-9765 April 4, 2013 2 | Building Technologies Office eere.energy.gov * Most buildings are not commissioned (Cx) before occupancy, including HVAC and lighting systems * Buildings often are poorly operated and maintained leading to significant energy waste of 5 to 20%, even when they have building automation systems (BASs)

134

ancient building system | OpenEI Community  

Open Energy Info (EERE)

ancient building system ancient building system Home Dc's picture Submitted by Dc(15) Member 15 November, 2013 - 13:26 Living Walls ancient building system architect biomimicry building technology cooling cu daylight design problem energy use engineer fred andreas geothermal green building heat transfer heating living walls metabolic adjustment net zero pre-electricity Renewable Energy Solar university of colorado utility grid Wind Much of the discussion surrounding green buildings centers around reducing energy use. The term net zero is the platinum standard for green buildings, meaning the building in question does not take any more energy from the utility grid than it produces using renewable energy resources, such as solar, wind, or geothermal installations (and sometimes these renewable energy resources actually feed energy back to the utility grid).

135

PR-PR: Cross-Platform Laboratory Automation System  

Science Journals Connector (OSTI)

Following our previous PR-PR report, it remained to demonstrate PR-PR as a cross-platform laboratory automation system, with support for liquid-handling robotics beyond the Tecan Freedom Evo platform, as well as for entirely distinct device categories including microfluidic devices, human languages (e.g., English), and even non-liquid-handling devices such as automated microscopy systems. ... Here, we report the development and deployment of a web-based software tool, j5, which automates the design of scar-less multipart DNA assembly protocols including SLIC, Gibson, CPEC, and Golden Gate. ...

Gregory Linshiz; Nina Stawski; Garima Goyal; Changhao Bi; Sean Poust; Monica Sharma; Vivek Mutalik; Jay D. Keasling; Nathan J. Hillson

2014-01-09T23:59:59.000Z

136

Security Assessment of Communication Networks for Integrated Substation Automation Systems  

Science Journals Connector (OSTI)

To assess the security of communication networks for integrated substation automation systems, a systematic approach based on ... to communication networks between the control center and substations through the a...

Huisheng Gao; Xuejiao Dai

2011-01-01T23:59:59.000Z

137

NREL: Technology Deployment - Building Energy Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Building Energy Systems Building Energy Systems NREL experts develop comprehensive energy assessments, models, and tools to optimize building systems across energy efficiency and renewable energy while also improving occupant comfort, safety, and productivity. Northeast Denver Housing Center Northeast Denver Housing Center NREL Identifies PV for 28 Affordable Housing Units Boulder County Housing Authority Boulder County Housing Authority NREL Recommendations Lead to 153 Net Zero Energy Residences Expertise and Knowledge NREL offers technical assistance and project development support by working closely with industry partners to research, develop, and deploy advanced building technologies. Examples include: Building Energy Audits and Assessments NREL provides technical assistance, guidelines, checklists, and data

138

The Study of Substation Automation Remote Communication for Multi-granularity Access Control System  

Science Journals Connector (OSTI)

This paper based on the demands of access control of substation automation system, analyzed two operation objects of ... can fulfill the needs of access control in substation automation.

Lichun Shi; Haimei Xiao

2012-01-01T23:59:59.000Z

139

Modeling of Residential Buildings and Heating Systems  

E-Print Network [OSTI]

-zone building model is used in each case. A model of the heating system is also used for the multi-storey building. Both co-heating and tracer gas measurements are used in order to adjust the parameters of each building model. A complete monitoring...

Masy, G.; Lebrun, J.

2004-01-01T23:59:59.000Z

140

Price Server System for Automated Critical Peak Pricing  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Price Server System for Automated Critical Peak Pricing Price Server System for Automated Critical Peak Pricing Speaker(s): David S. Watson Date: June 3, 2005 - 12:00pm Location: 90-3148 Overview of current California Energy Commission (CEC)/Demand Response Research Center (DRRC) Auto-CPP project: This summer, some select commercial CPP customers of PG&E will have the option of joining the Automated Critical Peak Pricing pilot. The pilot will have the same tariffs as standard CPP programs, but will include an added feature: automated shedding of electric loads. Through use of the Price Server System, day-ahead CPP event signals initiated by PG&E will ultimately cause electric loads to be automatically curtailed on commercial customer sites. These optional predetermined shed strategies will occur without

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

E-Print Network 3.0 - automation simulation system Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Summary: Information and Reservation System" "Automated Phone Book Management System" "Simulation of Searching Family... HMI" "Security System Simulator" "Performance Comparison...

142

Advanced Commercial Buildings Research; Electricity, Resources, & Building Systems Integration (Fact Sheet)  

SciTech Connect (OSTI)

Factsheet describing the Advanced Commercial Buildings Research group within NREL's Electricity, Resources, and Buildings Systems Integration Center.

Not Available

2009-09-01T23:59:59.000Z

143

Building America Webinar: Ductless Hydronic Distribution Systems...  

Energy Savers [EERE]

Ductless Hydronic Distribution Systems This webinar was presented by research team Alliance for Residential Building Innovation (ARBI), and reviewed findings from a feasibility...

144

Automated Test Coverage Measurement for Reactor Protection System Software  

E-Print Network [OSTI]

Automated Test Coverage Measurement for Reactor Protection System Software Implemented in Function- ing a case study using test cases prepared by domain experts for reactor protection system software) are widely used to implement safety- critical systems such as nuclear reactor protection systems, testing

145

RPP Computer Automated Surveillance System (CASS) to Tank Monitor and Control System (TMACS) transfer project plan  

SciTech Connect (OSTI)

Management plan to ensure the orderly, systematic transfer of alarms from the retired Computer Automated Surveillance System (CASS) to the Tank Monitor and Control System (TMACS).

SHIPLER, C.E.

1999-07-13T23:59:59.000Z

146

FEMP Presents Its Newest On-Demand eTraining Course on Building...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Presents Its Newest On-Demand eTraining Course on Building Automation Systems FEMP Presents Its Newest On-Demand eTraining Course on Building Automation Systems November 19, 2013 -...

147

Design and Operation of an Open, Interoperable Automated Demand Response Infrastructure for Commercial Buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

340E 340E Design and Operation of an Open, Interoperable Automated Demand Response Infrastructure for Commercial Buildings M.A. Piette, G. Ghatikar, S. Kiliccote, D. Watson Lawrence Berkeley National Laboratory E. Koch, D. Hennage Akuacom June 2009 Journal of Computing Science and Information Engineering, Vol. 9, Issue 2 DISCLAIMER This document was prepared as an account of work sponsored by the United States Government. While this document is believed to contain correct information, neither the United States Government nor any agency thereof, nor The Regents of the University of California, nor any of their employees, makes any warranty, express or implied, or assumes any legal responsibility for the accuracy, completeness, or usefulness of any information,

148

Security plan for the Automated Transportation Management System  

SciTech Connect (OSTI)

The Automated Transportation Management System (ATMS) is an unclassified non-sensitive system consisting of hardware and software designed to facilitate the shipment of goods for the US Department of Energy (DOE). The system is secured against waste, fraud, abuse, misuse, and programming errors through a series of security measures that are discussed in detail in this document.

Not Available

1994-04-01T23:59:59.000Z

149

KSL Kuttler Automation Systems GmbH | Open Energy Information  

Open Energy Info (EERE)

KSL Kuttler Automation Systems GmbH KSL Kuttler Automation Systems GmbH Jump to: navigation, search Name KSL-Kuttler Automation Systems GmbH Place Dauchingen, Baden-Württemberg, Germany Zip 78083 Sector Solar Product KSL-Kuttler Automation Systems GmbH is a manufacturer of automation systems for the PCB-industry and solar industry. KSL Kuttler was acquired by Suntech in April 2008. Coordinates 48.090319°, 8.552377° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":48.090319,"lon":8.552377,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

150

Reliability and component importance analysis of substation automation systems  

Science Journals Connector (OSTI)

This paper aims to present a comprehensive technique to quantitatively assess the reliability of substation automation systems. The technique is based on the tie-sets methodology. In order to demonstrate the application of the proposed technique, a variety of substation automation architectures is first introduced. The associated reliability block diagrams as well as the exact system reliability are then given. The impacts and the degree of importance of various components on the reliability of substation automation systems are presented. Two suitable measures of importance are selected. The first is the Birnbaum’s measure used to determine the bottleneck of the system reliability. The second measure uses criticality importance to diagnose failures and generating repair or inspection checklists.

Hamze Hajian-Hoseinabadi

2013-01-01T23:59:59.000Z

151

Building operating systems services: An architecture for programmable buildings.  

E-Print Network [OSTI]

7.3.2 Building Performance Analysis . . . . . . 7.4 RelatedWork 2.1 Building Physical Design . . . . . . . . . .3.2.6 Building Applications . . . . . . . . . . .

Dawson-Haggerty, Stephen

2014-01-01T23:59:59.000Z

152

Co-simulation of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

Developing an Integrated Building Design Tool by Couplingdesign energy ecient building systems in this complex setting, integrated

Trcka, Marija

2010-01-01T23:59:59.000Z

153

International Automated Systems Inc IAUS | Open Energy Information  

Open Energy Info (EERE)

International Automated Systems Inc IAUS International Automated Systems Inc IAUS Jump to: navigation, search Name International Automated Systems Inc (IAUS) Place Salem, Utah Zip 84653 Product Has developed a lens-based technology for concentrating heat in STEGSs, which it plans to deploy at projects. Coordinates 42.554485°, -88.110549° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.554485,"lon":-88.110549,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

154

AUTOMATED CRITICAL PEAK PRICING FIELD TESTS  

E-Print Network [OSTI]

AUTOMATED CRITICAL PEAK PRICING FIELD TESTS: 2006 PROGRAM DESCRIPTION AND RESULTS) for development of the DR Automation Server System This project could not have been completed without extensive: Greg Watson and Mark Lott · C&C Building Automation: Mark Johnson and John Fiegel · Chabot Space

155

3D World Building System  

SciTech Connect (OSTI)

This video provides an overview of the Sandia National Laboratories developed 3-D World Model Building capability that provides users with an immersive, texture rich 3-D model of their environment in minutes using a laptop and color and depth camera.

None

2013-10-30T23:59:59.000Z

156

3D World Building System  

ScienceCinema (OSTI)

This video provides an overview of the Sandia National Laboratories developed 3-D World Model Building capability that provides users with an immersive, texture rich 3-D model of their environment in minutes using a laptop and color and depth camera.

None

2014-02-26T23:59:59.000Z

157

ITU G.hn Concept and Home Automation  

Science Journals Connector (OSTI)

For long time, many in the buildings industry have been looking for a day when home automation systems would become fully integrated with communication...

Manfred Schneps-Schneppe

2009-01-01T23:59:59.000Z

158

Montana Sustainable Building Systems | Open Energy Information  

Open Energy Info (EERE)

Systems Systems Jump to: navigation, search Logo: Montana Sustainable Building Systems Name Montana Sustainable Building Systems Address 201 Second St E Place Whitefish, Montana Zip 59937 Sector Buildings Product Cross-laminated timber panel building systems Year founded 2009 Phone number 406-862-9222 Website http://www.smartwoods.com Coordinates 48.410317°, -114.340704° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":48.410317,"lon":-114.340704,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

159

Automation of Capacity Bidding with an Aggregator Using Open Automated Demand Response  

E-Print Network [OSTI]

Protocol for Building Automation and Control  Networks.  Protocol for Building Automation and Control  Networks, Demand Response Automation Server  Demand Response Research 

Kiliccote, Sila

2011-01-01T23:59:59.000Z

160

Green Building Certification Systems Requirement for New Federal Buildings and Major Renovations of Federal Buildings OIRA Comparison Document  

Broader source: Energy.gov [DOE]

Document details the Green Building Certification Systems Requirement for New Federal Buildings and Major Renovations of Federal Buildings' OIRA Comparison Document for 10 CFR Parts 433, 435 and 436.

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Thermal distribution systems in commercial buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Thermal distribution systems in commercial buildings Thermal distribution systems in commercial buildings Title Thermal distribution systems in commercial buildings Publication Type Journal Article LBNL Report Number LBNL-51860 Year of Publication 2003 Authors Diamond, Richard C., Craig P. Wray, Darryl J. Dickerhoff, Nance Matson, and Duo Wang Start Page Chapter Abstract Previous research suggests that HVAC thermal distribution systems in commercial buildings suffer from thermal losses, such as those caused by duct air leakage and poor duct location. Due to a lack of metrics and data showing the potentially large energy savings from reducing these losses, the California building industry has mostly overlooked energy efficiency improvements in this area. The purpose of this project is to obtain the technical knowledge needed to properly measure and understand the energy efficiency of these systems. This project has three specific objectives: to develop metrics and diagnostics for determining system efficiencies, to develop design and retrofit information that the building industry can use to improve these systems, and to determine the energy impacts associated with duct leakage airflows in an existing large commercial building. The primary outcome of this project is the confirmation that duct leakage airflows can significantly impact energy use in large commercial buildings: our measurements indicate that adding 15% duct leakage at operating conditions leads to an increase in fan power of about 25 to 35%. This finding is consistent with impacts of increased duct leakage airflows on fan power that have been predicted by previous simulations. Other project outcomes include the definition of a new metric for distribution system efficiency, the demonstration of a reliable test for determining duct leakage airflows, and the development of new techniques for duct sealing. We expect that the project outcomes will lead to new requirements for commercial thermal distribution system efficiency in future revisions of California's Title 24.

162

Building Groupwares over Duplicated Object Systems  

Science Journals Connector (OSTI)

Groupware toolkits let developers build applications for synchronous and distributed computer-based conferencing. Duplicated object systems (or DoS), on the other hand, manage distributed objects over the Internet and, since they include high-level features ...

Hechmi Khlifi; Jocelyn Desbiens; Mohamed Cheriet

2002-09-01T23:59:59.000Z

163

An Automation System for Optimizing a Supply Chain Network Design under the Influence of Demand Uncertainty  

E-Print Network [OSTI]

Automation . . . . . . . . . . . . . . . . . . . . . . iii 3Automation . . . . . . . . . . . . . . . . . . . . . . 5Dashboard/Cockpit Automation . . . . . . . . . . . . .

Polany, Rany

2012-01-01T23:59:59.000Z

164

Transforming Commercial Building Operations | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

& Publications Retrocommissioning and the Public Sector retrocommissioningpublicsector.doc Small- and Medium-Size Building Automation and Control System Needs: Scoping Study...

165

The Robo-AO automated intelligent queue system  

E-Print Network [OSTI]

Robo-AO is the first automated laser adaptive optics instrument. In just its second year of scientific operations, it has completed the largest adaptive optics surveys to date, each comprising thousands of targets. Robo-AO uses a fully automated queue scheduling system that selects targets based on criteria entered on a per observing program or per target basis, and includes the ability to coordinate with US Strategic Command automatically to avoid lasing space assets. This enables Robo-AO to select among thousands of targets at a time, and achieve an average observation rate of approximately 20 targets per hour.

Riddle, Reed L; Papadopoulos, Athanasios; Baranec, Christoph; Law, Nicholas M

2014-01-01T23:59:59.000Z

166

Conceptual design of an aircraft automated coating removal system  

SciTech Connect (OSTI)

Paint stripping of the U.S. Air Force`s large transport aircrafts is currently a labor-intensive, manual process. Significant reductions in costs, personnel and turnaround time can be accomplished by the judicious use of automation in some process tasks. This paper presents the conceptual design of a coating removal systems for the tail surfaces of the C-5 plane. Emphasis is placed on the technology selection to optimize human-automation synergy with respect to overall costs, throughput, quality, safety, and reliability. Trade- offs between field-proven vs. research-requiring technologies, and between expected gain vs. cost and complexity, have led to a conceptual design which is semi-autonomous (relying on the human for task specification and disturbance handling) yet incorporates sensor- based automation (for sweep path generation and tracking, surface following, stripping quality control and tape/breach handling).

Baker, J.E.; Draper, J.V.; Pin, F.G.; Primm, A.H.; Shekhar, S.

1996-05-01T23:59:59.000Z

167

Testing of complex IEC 61850 based substation automation systems  

Science Journals Connector (OSTI)

The integration of multifunctional intelligent substation devices (ISDs), in complex substation or power plant automation systems, requires the development of methods and tools for their testing that will ensure the correct operation of protection, control, monitoring, recording and metering functions, under normal and abnormal system conditions. The new IEC 61850 standard for communication networks and systems in substations allows the development of high-speed peer-to-peer communications based distributed applications, based on multicast of status changes or sampled analogue values. This paper details the requirements for the testing of complex substation automation systems. The testing methods need to correspond to the functional hierarchy of the substation automation system. Functional element testing, integration and system testing are discussed. Systems with Substation Bus only, and with both Process Bus and Substation Bus, are considered. A method for the testing of both types of system is proposed, based on a specific order of system components testing. Solutions for the testing of the individual components of the IEC 61850 based system, as well as for the testing of distributed applications, are described at the end of the paper.

Alexander Apostolov

2008-01-01T23:59:59.000Z

168

A Automated Tool for Supporting FMEAs of Digital Systems  

SciTech Connect (OSTI)

Although designs of digital systems can be very different from each other, they typically use many of the same types of generic digital components. Determining the impacts of the failure modes of these generic components on a digital system can be used to support development of a reliability model of the system. A novel approach was proposed for such a purpose by decomposing the system into a level of the generic digital components and propagating failure modes to the system level, which generally is time-consuming and difficult to implement. To overcome the associated issues of implementing the proposed FMEA approach, an automated tool for a digital feedwater control system (DFWCS) has been developed in this study. The automated FMEA tool is in nature a simulation platform developed by using or recreating the original source code of the different module software interfaced by input and output variables that represent physical signals exchanged between modules, the system, and the controlled process. For any given failure mode, its impacts on associated signals are determined first and the variables that correspond to these signals are modified accordingly by the simulation. Criteria are also developed, as part of the simulation platform, to determine whether the system has lost its automatic control function, which is defined as a system failure in this study. The conceptual development of the automated FMEA support tool can be generalized and applied to support FMEAs for reliability assessment of complex digital systems.

Yue,M.; Chu, T.-L.; Martinez-Guridi, G.; Lehner, J.

2008-09-07T23:59:59.000Z

169

Building Energy Information Systems: User Case Studies  

E-Print Network [OSTI]

1.5M) Campus (83,000) Automated Logic Corporation (ALC)Data Sources Benchmarks Automated Logic Corporation WebCTRL

Granderson, Jessica

2010-01-01T23:59:59.000Z

170

Balancing Hydronic Systems in Multifamily Buildings  

SciTech Connect (OSTI)

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

Ruch, R.; Ludwig, P.; Maurer, T.

2014-07-01T23:59:59.000Z

171

Energy Savings Through Improved Mechanical Systems and Building...  

Office of Environmental Management (EM)

Energy Savings Through Improved Mechanical Systems and Building Envelope Technologies (DE-FOA-0000621) Energy Savings Through Improved Mechanical Systems and Building Envelope...

172

Evaluation of Automated Model Calibration Techniques for Residential Building Energy Simulation  

SciTech Connect (OSTI)

This simulation study adapts and applies the general framework described in BESTEST-EX (Judkoff et al 2010) for self-testing residential building energy model calibration methods. BEopt/DOE-2.2 is used to evaluate four mathematical calibration methods in the context of monthly, daily, and hourly synthetic utility data for a 1960's-era existing home in a cooling-dominated climate. The home's model inputs are assigned probability distributions representing uncertainty ranges, random selections are made from the uncertainty ranges to define 'explicit' input values, and synthetic utility billing data are generated using the explicit input values. The four calibration methods evaluated in this study are: an ASHRAE 1051-RP-based approach (Reddy and Maor 2006), a simplified simulated annealing optimization approach, a regression metamodeling optimization approach, and a simple output ratio calibration approach. The calibration methods are evaluated for monthly, daily, and hourly cases; various retrofit measures are applied to the calibrated models and the methods are evaluated based on the accuracy of predicted savings, computational cost, repeatability, automation, and ease of implementation.

Robertson, J.; Polly, B.; Collis, J.

2013-09-01T23:59:59.000Z

173

Chip breaking system for automated machine tool  

DOE Patents [OSTI]

The invention is a rotary selectively directional valve assembly for use in an automated turret lathe for directing a stream of high pressure liquid machining coolant to the interface of a machine tool and workpiece for breaking up ribbon-shaped chips during the formation thereof so as to inhibit scratching or other marring of the machined surfaces by these ribbon-shaped chips. The valve assembly is provided by a manifold arrangement having a plurality of circumferentially spaced apart ports each coupled to a machine tool. The manifold is rotatable with the turret when the turret is positioned for alignment of a machine tool in a machining relationship with the workpiece. The manifold is connected to a non-rotational header having a single passageway therethrough which conveys the high pressure coolant to only the port in the manifold which is in registry with the tool disposed in a working relationship with the workpiece. To position the machine tools the turret is rotated and one of the tools is placed in a material-removing relationship of the workpiece. The passageway in the header and one of the ports in the manifold arrangement are then automatically aligned to supply the machining coolant to the machine tool workpiece interface for breaking up of the chips as well as cooling the tool and workpiece during the machining operation.

Arehart, Theodore A. (Clinton, TN); Carey, Donald O. (Oak Ridge, TN)

1987-01-01T23:59:59.000Z

174

Systems for home automation are a necessary component for intelligent smart homes applications.  

E-Print Network [OSTI]

Abstract Systems for home automation are a necessary component for intelligent smart homes to provide semantically rich unification over a range of home- and web-based automation systems. 1. Introduction Whilst a number of automation systems for smart homes are available commercially, their use

Dobson, Simon

175

Robotic control architecture development for automated nuclear material handling systems  

SciTech Connect (OSTI)

Lawrence Livermore National Laboratory (LLNL) is engaged in developing automated systems for handling materials for mixed waste treatment, nuclear pyrochemical processing, and weapon components disassembly. In support of these application areas there is an extensive robotic development program. This paper will describe the portion of this effort at LLNL devoted to control system architecture development, and review two applications currently being implemented which incorporate these technologies.

Merrill, R.D.; Hurd, R.; Couture, S.; Wilhelmsen, K.

1995-02-01T23:59:59.000Z

176

Development and Evaluation of an Automated Annotation Pipeline and cDNA Annotation System  

E-Print Network [OSTI]

Development and Evaluation of an Automated Annotation Pipeline and cDNA Annotation System Takeya, including an automated annotation pipeline that provides high-quality preliminary annotation for each

Gough, Julian

177

Durra Building Systems | Open Energy Information  

Open Energy Info (EERE)

Durra Building Systems Durra Building Systems Jump to: navigation, search Name Durra Building Systems Place Whitewright, Texas Zip 75491 Product Creates contruction panels from wheat straw using a patented production process. Coordinates 33.512685°, -96.393299° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":33.512685,"lon":-96.393299,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

178

Building operating systems services: An architecture for programmable buildings.  

E-Print Network [OSTI]

few feeds into the building substation, which are split intodown to 480V at the building substation, from where it isService Meter West Campus Substation 12KV Service 12KV/480V

Dawson-Haggerty, Stephen

2014-01-01T23:59:59.000Z

179

Duct Systems in Large Commercial Buildings: Physical  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Duct Systems in Large Commercial Buildings: Physical Characterization, Air Leakage, and Heat Conduction Gains William 1. Fisk, Woody Delp, Rick Diamond, Darryl Dickerhoff, Ronnen Levinson, Mark Modera, Matty Nematollahi, Duo Wang Environmental Energy Technologies Division Indoor Environment Department Lawrence Berkeley National Laboratory Berkeley CA 94720 March 30, 1999 This work was supported by the Assistant Secretary for Energy Efficiency and Renewable Energy, Office of Building Technology and Community Systems, of the US Department of Energy under Contract No. DE-AC03-76SF00098 and by the California Institute For Energy Efficiency. LBNL-42339

180

Automated Fault Location In Smart Distribution Systems  

E-Print Network [OSTI]

measured at the power substation during a single phase to ground fault clearance [17] .............................................. 111 Figure 26 Analyzed signal using wavelet transform from phase B current during a fault [17..., but are not limited to, substation and feeder relay, intelligent controllers for capacitor bank switches or reclosers, Automatic Meter Reading (AMR) systems installed at the customer sites, power quality meters installed at strategic locations in the system, low...

Lotfifard, Saeed

2012-10-19T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Hanford site Computer Automated Mapping Information System (CAMIS)  

SciTech Connect (OSTI)

The Computer Automated Mapping Information System (CAMIS) provides sitewide, networked access to CAD based geographically referenced data. CAMIS allows multiple organizations to maintain and share their data. Information collected and managed according to site-wide standards, enables each organization to focus their limited resources on data issues tied to their own discipline without having to collect or manage reference data outside their respective domains. Sharing information also minimizes redundant data and helps improve the overall quality of the sites` data resources.

Rush, S.F. [ICF Kaiser Hanford Co., Richland, WA (United States)

1995-09-01T23:59:59.000Z

182

Software support for building end-user programming environments in the automation domain  

Science Journals Connector (OSTI)

Projects in the automation domain often require that end users, who are the machine operators, have means to change control software to make adaptations and optimizations for the machining task at hand. Although they usually do not have any software ... Keywords: domain-specific language, end-user programming, industrial automation, visual language, visual programming

Herbert Prähofer; Dominik Hurnaus; Roland Schatz; Christian Wirth; Hanspeter Mössenbö k

2008-05-01T23:59:59.000Z

183

Development of a Model Specification for Performance MonitoringSystems for Commercial Buildings  

SciTech Connect (OSTI)

The paper describes the development of a model specification for performance monitoring systems for commercial buildings. The specification focuses on four key aspects of performance monitoring: (1) performance metrics; (2) measurement system requirements; (3) data acquisition and archiving; and (4) data visualization and reporting. The aim is to assist building owners in specifying the extensions to their control systems that are required to provide building operators with the information needed to operate their buildings more efficiently and to provide automated diagnostic tools with the information required to detect and diagnose faults and problems that degrade energy performance. The paper reviews the potential benefits of performance monitoring, describes the specification guide and discusses briefly the ways in which it could be implemented. A prototype advanced visualization tool is also described, along with its application to performance monitoring. The paper concludes with a description of the ways in which the specification and the visualization tool are being disseminated and deployed.

Haves, Philip; Hitchcock, Robert J.; Gillespie, Kenneth L.; Brook, Martha; Shockman, Christine; Deringer, Joseph J.; Kinney,Kristopher L.

2006-08-01T23:59:59.000Z

184

Energy Management Systems Package for Small Commercial Buildings...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

More Documents & Publications Building America System Research Multi-Function Fuel-Fired Heat Pump - 2013 Peer Review Buildings Performance Database - 2013 BTO...

185

Green Building Certification Systems Requirement for New Federal...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

CFR Parts 433, 435 and 436. greenblgcertcompare2014.docx More Documents & Publications Green Building Certification Systems Requirement for New Federal Buildings and Major...

186

Buildings Energy Data Book: 5.5 Thermal Distribution Systems  

Buildings Energy Data Book [EERE]

Building Type and System Type (Million SF) Total Education Food Sales Food Service Health Care Lodging Mercantile and Service Office Public Buildings WarehouseStorage Total...

187

An automated miniature robotic vehicle inspection system  

SciTech Connect (OSTI)

A novel, autonomous reconfigurable robotic inspection system for quantitative NDE mapping is presented. The system consists of a fleet of wireless (802.11g) miniature robotic vehicles, each approximately 175 × 125 × 85 mm with magnetic wheels that enable them to inspect industrial structures such as storage tanks, chimneys and large diameter pipe work. The robots carry one of a number of payloads including a two channel MFL sensor, a 5 MHz dry coupled UT thickness wheel probe and a machine vision camera that images the surface. The system creates an NDE map of the structure overlaying results onto a 3D model in real time. The authors provide an overview of the robot design, data fusion algorithms (positioning and NDE) and visualization software.

Dobie, Gordon; Summan, Rahul; MacLeod, Charles; Pierce, Gareth; Galbraith, Walter [Centre for Ultrasonic Engineering, University of Strathclyde, 204 George Street, Glasgow, G1 1XW (United Kingdom)

2014-02-18T23:59:59.000Z

188

Performance Enhancement of the Automated Concrete Evaluation System (ACES)  

SciTech Connect (OSTI)

The objective of this proposed research is to improve and expand the detection and analysis capabilities of the automated, concrete evaluation (ACE) system. MoDOT and Honeywell jointly developed this system. The focus of this proposed research will be on the following: Coordination of concrete imaging efforts with other states, Validation and testing of the ACE system on a broad range of concrete samples, and Identification and development of software and hardware enhancements. These enhancements will meet the needs of diverse users in the field of concrete materials, construction, and research.

Baumgart,C.W.; Cave,S.P.; Linder,K.E.

2002-02-14T23:59:59.000Z

189

Field Demonstration of Automated Demand Response for Both Winter and Summer Events in Large Buildings in the Pacific Northwest  

E-Print Network [OSTI]

of fully automated demand response in large facilities,2009). Open Automated Demand Response CommunicationsOpen Automated Demand Response Technology Demonstration

Piette, Mary Ann

2014-01-01T23:59:59.000Z

190

A model and framework for reliable build systems Derrick Coetzee  

E-Print Network [OSTI]

A model and framework for reliable build systems Derrick Coetzee Anand Bhaskar George Necula, requires prior specific permission. #12;A model and framework for reliable build systems Derrick Coetzee- distributed, incremental, parallel build systems. We de- fine a general model for resources accessed by build

Necula, George

191

Are CHP Systems Ready for Commercial Buildings?  

SciTech Connect (OSTI)

This paper highlights challenges associated with integration of CHP systems with existing buildings and maintaining their performance over time. The paper also identifies key research and development needs to address the challenges, so that CHP technologies can deliver the promised performance and reach their full potential market penetration.

Katipamula, Srinivas; Brambley, Michael R.; Zaltash, Abdi; Sands, Jim

2005-06-27T23:59:59.000Z

192

Automated Monitoring System for Waste Disposal Sites and Groundwater  

SciTech Connect (OSTI)

A proposal submitted to the U.S. Department of Energy (DOE), Office of Science and Technology, Accelerated Site Technology Deployment (ASTD) program to deploy an automated monitoring system for waste disposal sites and groundwater, herein referred to as the ''Automated Monitoring System,'' was funded in fiscal year (FY) 2002. This two-year project included three parts: (1) deployment of cellular telephone modems on existing dataloggers, (2) development of a data management system, and (3) development of Internet accessibility. The proposed concept was initially (in FY 2002) to deploy cellular telephone modems on existing dataloggers and partially develop the data management system at the Nevada Test Site (NTS). This initial effort included both Bechtel Nevada (BN) and the Desert Research Institute (DRI). The following year (FY 2003), cellular modems were to be similarly deployed at Sandia National Laboratories (SNL) and Los Alamos National Laboratory (LANL), and the early data management system developed at the NTS was to be brought to those locations for site-specific development and use. Also in FY 2003, additional site-specific development of the complete system was to be conducted at the NTS. To complete the project, certain data, depending on site-specific conditions or restrictions involving distribution of data, were to made available through the Internet via the DRI/Western Region Climate Center (WRCC) WEABASE platform. If the complete project had been implemented, the system schematic would have looked like the figure on the following page.

S. E. Rawlinson

2003-03-01T23:59:59.000Z

193

Design and Operation of an Open, Interoperable Automated Demand Response Infrastructure for Commercial Buildings  

SciTech Connect (OSTI)

This paper describes the concept for and lessons from the development and field-testing of an open, interoperable communications infrastructure to support automated demand response (auto-DR). Automating DR allows greater levels of participation, improved reliability, and repeatability of the DR in participating facilities. This paper also presents the technical and architectural issues associated with auto-DR and description of the demand response automation server (DRAS), the client/server architecture-based middle-ware used to automate the interactions between the utilities or any DR serving entity and their customers for DR programs. Use case diagrams are presented to show the role of the DRAS between utility/ISO and the clients at the facilities.

Piette, Mary Ann; Ghatikar, Girish; Kiliccote, Sila; Watson, David; Koch, Ed; Hennage, Dan

2009-05-01T23:59:59.000Z

194

Building Energy Monitoring System: Making Energy Manageable  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Building Energy Monitoring System: Making Energy Manageable Building Energy Monitoring System: Making Energy Manageable Speaker(s): Bob Hunter Date: July 21, 2006 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Peng Xu For any line-item expense to be managed, it must first be manageable. In most organizations, this means bringing that expense into the budget/forecast/variance cycle at the department and individual level. While energy costs are the second fastest growing for most organizations, they have simply received a pass on individual accountability. TrendPoint provides a patented system for monitoring energy at the department and user-level. By monitoring each circuit, we assign a circuit to a user, each user to a group and each group to a site. Energy budgets can then be created and assigned to departments, allowing energy costs become a part of

195

Daylighting control systems : Daylighting The New York Times Building  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

control systems control systems Overview The architectural approach The owner's approach Daylighting field study Daylighting control systems Automated roller shades Procurement specifications Shades and Shade Controls Lighting Controls Visualizing daylight Commissioning/ verification Demand response Mainstream solutions Post-occupancy evaluation Publications Sponsors Project team Daylighting control systems Lighting energy savings were greater in zones daylit bilaterally from both the southwest and northwest facades, typically 50-60% at 11 feet from the windows and 25-40% at 14-25 feet from the façade. Total illuminance was maintained in all lighting zones to within -10% of the setpoint for 95-100% of the day throughout most of the nine-month monitored period. Daylight "harvesting" strategies are implemented using daylighting control systems that dim the electric lighting in response to interior daylight levels. For commercial applications, the light output of fluorescent lamps (T5 or T8) are varied by using electronic dimming ballasts. Photosensors, typically mounted in the ceiling, are used to measure the quantity of daylight in the space then determine the amount of dimming required to maintain the design work plane illuminance level. If daylight levels are more than adequate, the electric lights can be shut off. Simulation studies indicate that annual energy use and peak demand can be reduced by 20-30% compared to a non-daylit building. These technological solutions are increasingly becoming one of the key means to achieving compliance with stringent energy-efficiency standards and achieving LEED ratings for sustainable design.

196

Building Energy Software Tools Directory: System Analyzer  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

System Analyzer System Analyzer System Analyzer logo. Software package for load calculation and energy and economic comparative analysis. System Analyzer permits a quick evaluation of virtually any building, system, and equipment combination. Thus, it can be used either as a scoping tool to decide what systems may be appropriate for an initial design, or to get a general feeling of how one system/equipment combination may perform over another. If a certain combination seems especially promising, further analysis can be done by exporting inputs into TRACE 600. The possibilities are endless. And since the program is Windows-based, virtually anyone with minimal HVAC training and experience can use it. Keywords Energy analyses, load calculation, comparison of system and equipment

197

Financing Turnkey Efficiency Solutions for Small Buildings and...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

s14langner040413.pdf More Documents & Publications Small- and Medium-Size Building Automation and Control System Needs: Scoping Study Technology Performance Exchange - 2013 BTO...

198

AIAA 94-1214: Using generic tool kits to build intelligent systems  

SciTech Connect (OSTI)

The Intelligent Systems and Robotics Center at Sandia National Laboratories is developing technologies for the automation of processes associated with environmental remediation and information-driven manufacturing. These technologies, which focus on automated planning and programming and sensor-based and model-based control, are used to build intelligent systems which are able to generate plans of action, program the necessary devices, and use sensors to react to changes in the environment. By automating tasks through the use of programmable devices tied to computer models which are augmented by sensing, requirements for faster, safer, and cheaper systems are being satisfied. However, because of the need for rapid cost-effective prototyping and multi-laboratory teaming, it is also necessary to define a consistent approach to the construction of controllers for such systems. As a result, the Generic Intelligent System Controller (GISC) concept has been developed. This concept promotes the philosophy of producing generic tool kits which can be used and reused to build intelligent control systems.

Miller, D.J.

1993-12-31T23:59:59.000Z

199

E-Print Network 3.0 - accurate automated protein Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

assignment appears to be more accurate than the human assignment is shown... and automated model building with cell modeling systems will permit accurate, well-structured...

200

Reference Model for Control and Automation Systems in Electrical Power  

Broader source: Energy.gov (indexed) [DOE]

Reference Model Reference Model for Control and Automation Systems in Electrical Power Version 1.2 October 12, 2005 Prepared by: Sandia National Laboratories' Center for SCADA Security Jason Stamp, Technical Lead Michael Berg, Co-Technical Lead Michael Baca, Project Lead This work was conducted for the DOE Office of Electricity Delivery and Energy Reliability under Contract M64SCADSNL Sandia is a multiprogram laboratory operated by Sandia Corporation, a Lockheed Martin Company, for the United States Department of Energy's National Nuclear Security Administration under contract DE-AC04-94AL85000. 2 Contents 1 Executive Summary.................................................................................................3 2 Introduction..............................................................................................................4

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Pitfalls in Building and HVAC Systems  

E-Print Network [OSTI]

the summer savings. ? Consider all forms of savings, not just en ergy. Opportunities are often missed be cause only energy savings are consideted. For example, the installation of extetior wall insulation or aluminum thermopane win dows result in a...PITFALLS IN BUILDING AND HVAC SYSTEMS B. N. Gidwani, P.E. Roy F. Weston, Inc. West Chester, Pennsylvania ABSTRACT The purpose of an energy audit is to identify and analyze areas of energy consumption and to pro pose methods of conservation...

Gidwani, B. N.

202

Implementation of embedded Ethernet based on hardware protocol stack in substation automation system  

Science Journals Connector (OSTI)

Embedded Ethernet technology has been utilized increasingly widely as the communication mode in the substation automation system (SAS). This paper introduces...

Qiang Ma ? ?; Jianguo Zhao ???; Bingxu Liu ???

2008-04-01T23:59:59.000Z

203

Reference Model for Control and Automation Systems in Electrical Power (October 2005)  

Broader source: Energy.gov [DOE]

Modern infrastructure automation systems are threatened by cyber attack. Their higher visibility in recent years and the increasing use of modern information technology (IT) components contribute...

204

Automated piecewise power-law modeling of biological systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Machina, Machina, A., et al., Automated piecewise power-law modeling of biological systems. J. Biotechnol. (2010), doi:10.1016/j.jbiotec.2009.12.016 ARTICLE IN PRESS G Model BIOTEC-5384; No. of Pages 12 Journal of Biotechnology xxx (2010) xxx-xxx Contents lists available at ScienceDirect Journal of Biotechnology j o u r n a l h o m e p a g e : w w w . e l s e v i e r . c o m / l o c a t e / j b i o t e c Automated piecewise power-law modeling of biological systems Anna Machina a,b,1,2 , Arkady Ponosov b,2 , Eberhard O. Voit a,∗ a Integrative BioSystems Institute and Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, 313 Ferst Drive, Suite 4103, Atlanta, GA 30332-0535, United States b Centre for Integrative Genetics (CIGENE), CIGENE, Arboretveien 6, 1432 Ås, Norway a r t i c l e i n f o Article history: Received 20 August 2009 Received in revised form 16 December 2009 Accepted

205

Building America Webinar: Central Multifamily Water Heating Systems...  

Energy Savers [EERE]

Building America Webinar: Central Multifamily Water Heating Systems Building America Webinar: Central Multifamily Water Heating Systems January 21, 2015 3:00PM to 4:30PM EST This...

206

Building America Webinar: Central Multifamily Water Heating Systems...  

Energy Savers [EERE]

Building America Webinar: Central Multifamily Water Heating Systems Building America Webinar: Central Multifamily Water Heating Systems January 21, 2015 11:00AM to 12:30PM MST...

207

Automation of Pivot Sprinkler Irrigation Systems to More Efficiently Utilize Rainfall and Irrigation Water  

E-Print Network [OSTI]

A study was conducted to develop automated pivot sprinkler irrigation systems and determine if such systems use less water and energy than manually operated systems. The study was conducted near Earth, Texas, using irrigation systems located...

Wendt, C. W.; Runkles, J. R.; Gerst, M. D.; Harbert, H. P. III; Hutmacher, R. B.

208

Automated questionnaire for sensitive positions, SF-86 (QSP system)  

SciTech Connect (OSTI)

In 1988, the office of Personnel Management drastically revised the investigative form used as a source document in conducting background investigations. To manually produce the revised form, the Questionnaire for Sensitive Positions, the Westinghouse Hanford Company/Boeing Computer Services, Richland, Inc., would have required an estimated increased staff effort of 32%. One alternative was to create a computer-aided system, the Automated Questionnaire for Sensitive Positions. Through development and implementation of the system, the need for additional staffing has been eliminated, the predetermined reinvestigation submission quotas have been maintained, and the Office of Personnel Management rejection rate has been reduced to less than 1%. There are currently 20 known facilities successfully using the US Department of Energy and Office of Personnel Management approved Automated Questionnaire for Sensitive Positions. By storing a facsimile of the Questionnaire for Sensitive Positions form in the laser printer's memory, using electronic forms-generation software, an applicant or employee data file is merged with this electronic form image and printed together as one form. The applicant or employee data can be retained indefinitely with minimal file updates for the five-year reinvestigation or other investigations, as needed.

Fisher, M.J.; Deatherage, K.W. (Westinghouse Hanford Co., Richland, WA (United States) Boeing Computer Services Co., Richland, WA (United States))

1991-07-01T23:59:59.000Z

209

A Mobile Automated Tomographic Gamma Scanning System - 13231  

SciTech Connect (OSTI)

Canberra Industries have recently designed and built a new automated Tomographic Gamma Scanning (TGS) system for mobile deployment. The TGS technique combines high-resolution gamma spectroscopy with low spatial resolution 3-dimensional image reconstruction to provide increased accuracy over traditional approaches for the assay of non-uniform source distributions in low-to medium-density, non-heterogeneous matrices. Originally pioneered by R. Estep at Los Alamos National Laboratory (LANL), the TGS method has been further developed and commercialized by Canberra Industries in recent years. The present system advances the state of the art on several fronts: it is designed to be housed in a standard cargo transport container for ease of transport, allowing waste characterization at multiple facilities under the purview of a single operator. Conveyor feed, drum rotator, and detector and collimator positioning mechanisms operated by programmable logic control (PLC) allow automated batch mode operation. The variable geometry settings can accommodate a wide range of waste packaging, including but not limited to standard 220 liter drums, 380 liter overpack drums, and smaller 20 liter cans. A 20 mCi Eu-152 transmission source provides attenuation corrections for drum matrices up to 1 g/cm{sup 3} in TGS mode; the system can be operated in Segmented Gamma Scanning (SGS) mode to measure higher density drums. To support TGS assays at higher densities, the source shield is sufficient to house an alternate Co-60 transmission source of higher activity, up to 250 mCi. An automated shutter and attenuator assembly is provided for operating the system with a dual intensity transmission source. The system's 1500 kg capacity rotator turntable can handle heavy containers such as concrete lined 380 liter overpack drums. Finally, data acquisition utilizes Canberra's Broad Energy Germanium (BEGE) detector and Lynx MCA, with 32 k channels, providing better than 0.1 keV/channel resolution to support both isotopic analysis with the MGA/MGAU software and a wide 3 MeV dynamic range. The calibration and verification of the system is discussed, and quantitative results are presented for a variety of drum types and matrices. (authors)

Kirkpatrick, J.M.; LeBlanc, P.J.; Nakazawa, D.; Petroka, D.L.; Kane Smith, S.; Venkataraman, R.; Villani, M. [Canberra Industries, Inc. 800 Research Parkway, Meriden CT 06450 (United States)] [Canberra Industries, Inc. 800 Research Parkway, Meriden CT 06450 (United States)

2013-07-01T23:59:59.000Z

210

Home Automation  

E-Print Network [OSTI]

In this paper I briefly discuss the importance of home automation system. Going in to the details I briefly present a real time designed and implemented software and hardware oriented house automation research project, capable of automating house's electricity and providing a security system to detect the presence of unexpected behavior.

Ahmed, Zeeshan

2010-01-01T23:59:59.000Z

211

Index to Evaluate Energy Efficiency of the Building HVAC System  

E-Print Network [OSTI]

1An Index to Evaluate Energy Efficiency of the Entire Building HVAC System Presented by Dr. Claridge Date: 09/15/2014 ESL-IC-14-09-15 Proceedings of the 14th International Conference for Enhanced Building Operations, Beijing, China, September 14..., Beijing, China, September 14-17, 2014 3• Why we need the Energy/Load Ratio 1. Building 2. HVAC Systems 3. Common Index • Building sector consumes 40% of total energy usage in US (Residential buildings – 22%, Commercial building – 19%) • HVAC systems...

Wang, L.; Wang, L.; Claridge,D.

2014-01-01T23:59:59.000Z

212

Demo: BACChat: A Building Automation Control Client for Sensor Data Collection  

E-Print Network [OSTI]

% of the total energy usage in the United States while the rest goes to transportation and industry [1]. In some and residential buildings in energy consumption is even higher (in Hong Kong 2008, the figure is 65% [2]). As such (BMS), which plays a key role in maintaining the operation, energy efficiency, and safety of a building

Wang, Dan

213

DYNAMIC CONTROL OF A FLOW-RACK AUTOMATED STORAGE AND RETRIEVAL SYSTEM  

E-Print Network [OSTI]

DYNAMIC CONTROL OF A FLOW-RACK AUTOMATED STORAGE AND RETRIEVAL SYSTEM Khalid HACHEMI*, **, Hassane (CPN) for a flow-rack automated storage and retrieval system. The AS/RS is modelled using Coloured Petri nets, the developed model has been used to capture and provide the rack state. We introduce

Paris-Sud XI, Université de

214

Modelling and Verification of Automated Transit Systems, Using Timed Automata, Invariants and  

E-Print Network [OSTI]

Modelling and Verification of Automated Transit Systems, Using Timed Automata, Invariants in automated transit systems. The problems we consider are in- spired by design work in the Personal Rapid and Simulations Nancy Lynch * Laboratory for Computer Science, Massachusetts Institute of Technology, Cambridge

Lynch, Nancy

215

Modelling and Veri cation of Automated Transit Systems, using Timed Automata, Invariants and  

E-Print Network [OSTI]

Modelling and Veri cation of Automated Transit Systems, using Timed Automata, Invariants in automated transit systems. The problems we consider are in- spired by design work in the Personal Rapid and Simulations Nancy Lynch ? Laboratory for Computer Science, Massachusetts Institute of Technology, Cambridge

Lynch, Nancy

216

Requirements Specification for and Evaluation of an Automated Substation Monitoring System  

E-Print Network [OSTI]

, without to much disruption in power supply to the users, Equipment Condition Monitoring (ECM) has to beRequirements Specification for and Evaluation of an Automated Substation Monitoring System Mladen for the Automated Analysis Substation System (AASS) implemented at Texas A&M University, aimed at monitoring

217

Integrated Energy Systems (IES) for Buildings: A Market Assessment...  

Broader source: Energy.gov (indexed) [DOE]

Energy Systems (IES) for Buildings: A Market Assessment, September 2002 Integrated Energy Systems (IES) combine on-site power or distributed generation technologies with thermally...

218

Building Codes and Regulations for Solar Water Heating Systems | Department  

Broader source: Energy.gov (indexed) [DOE]

Building Codes and Regulations for Solar Water Heating Systems Building Codes and Regulations for Solar Water Heating Systems Building Codes and Regulations for Solar Water Heating Systems June 24, 2012 - 1:50pm Addthis Photo Credit: iStockphoto Photo Credit: iStockphoto Before installing a solar water heating system, you should investigate local building codes, zoning ordinances, and subdivision covenants, as well as any special regulations pertaining to the site. You will probably need a building permit to install a solar energy system onto an existing building. Not every community or municipality initially welcomes residential renewable energy installations. Although this is often due to ignorance or the comparative novelty of renewable energy systems, you must comply with existing building and permit procedures to install your system.

219

Building Codes and Regulations for Solar Water Heating Systems | Department  

Broader source: Energy.gov (indexed) [DOE]

Building Codes and Regulations for Solar Water Heating Systems Building Codes and Regulations for Solar Water Heating Systems Building Codes and Regulations for Solar Water Heating Systems June 24, 2012 - 1:50pm Addthis Photo Credit: iStockphoto Photo Credit: iStockphoto Before installing a solar water heating system, you should investigate local building codes, zoning ordinances, and subdivision covenants, as well as any special regulations pertaining to the site. You will probably need a building permit to install a solar energy system onto an existing building. Not every community or municipality initially welcomes residential renewable energy installations. Although this is often due to ignorance or the comparative novelty of renewable energy systems, you must comply with existing building and permit procedures to install your system.

220

Cyber-Physical Energy Systems: Focus on Smart Buildings  

E-Print Network [OSTI]

of a deeply coupled system of energy usage, comfort and work derived. At a macroscale, buildings use approxiCyber-Physical Energy Systems: Focus on Smart Buildings Jan Kleissl Dept. of Mechanical- tributions: one, a careful examination of different types of buildings and their energy use; two

Gupta, Rajesh

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

WASTE HANDLING BUILDING FIRE PROTECTION SYSTEM DESCRIPTION DOCUMENT  

SciTech Connect (OSTI)

The Waste Handling Building Fire Protection System provides the capability to detect, control, and extinguish fires and/or mitigate explosions throughout the Waste Handling Building (WHB). Fire protection includes appropriate water-based and non-water-based suppression, as appropriate, and includes the distribution and delivery systems for the fire suppression agents. The Waste Handling Building Fire Protection System includes fire or explosion detection panel(s) controlling various detectors, system actuation, annunciators, equipment controls, and signal outputs. The system interfaces with the Waste Handling Building System for mounting of fire protection equipment and components, location of fire suppression equipment, suppression agent runoff, and locating fire rated barriers. The system interfaces with the Waste Handling Building System for adequate drainage and removal capabilities of liquid runoff resulting from fire protection discharges. The system interfaces with the Waste Handling Building Electrical Distribution System for power to operate, and with the Site Fire Protection System for fire protection water supply to automatic sprinklers, standpipes, and hose stations. The system interfaces with the Site Fire Protection System for fire signal transmission outside the WHB as needed to respond to a fire emergency, and with the Waste Handling Building Ventilation System to detect smoke and fire in specific areas, to protect building high-efficiency particulate air (HEPA) filters, and to control portions of the Waste Handling Building Ventilation System for smoke management and manual override capability. The system interfaces with the Monitored Geologic Repository (MGR) Operations Monitoring and Control System for annunciation, and condition status.

J. D. Bigbee

2000-06-21T23:59:59.000Z

222

Building Energy Information Systems: User Case Studies  

SciTech Connect (OSTI)

Measured energy performance data are essential to national efforts to improve building efficiency, as evidenced in recent benchmarking mandates, and in a growing body of work that indicates the value of permanent monitoring and energy information feedback. This paper presents case studies of energy information systems (EIS) at four enterprises and university campuses, focusing on the attained energy savings, and successes and challenges in technology use and integration. EIS are broadly defined as performance monitoring software, data acquisition hardware, and communication systems to store, analyze and display building energy information. Case investigations showed that the most common energy savings and instances of waste concerned scheduling errors, measurement and verification, and inefficient operations. Data quality is critical to effective EIS use, and is most challenging at the subsystem or component level, and with non-electric energy sources. Sophisticated prediction algorithms may not be well understood but can be applied quite effectively, and sites with custom benchmark models or metrics are more likely to perform analyses external to the EIS. Finally, resources and staffing were identified as a universal challenge, indicating a need to identify additional models of EIS use that extend beyond exclusive in-house use, to analysis services.

Granderson, Jessica; Piette, Mary Ann; Ghatikar, Girish

2010-03-22T23:59:59.000Z

223

An analysis model for wind resistance performance of automated exterior wall painting robots in apartment buildings  

Science Journals Connector (OSTI)

The painting of exterior walls on apartment buildings involves ... to fatalities. Although the market for domestic painting is expanding, painters tend to avoid the risk of painting exterior walls. Accordingly, m...

Ji-Won Cho; Jeong-Ho Lee; Young-Suk Kim…

2014-05-01T23:59:59.000Z

224

Wind Measurement and Archival under the Automated Surface Observing System (ASOS): User Concerns and Opportunity for Improvement  

Science Journals Connector (OSTI)

The National Weather Service, as a part of its modernization effort, is implementing the Automated Surface Observing System (ASOS). Much discussion has occurred about various aspects of ASOS versus the current system of manual and automated ...

Mark D. Powell

1993-04-01T23:59:59.000Z

225

Energy management systems for commercial buildings. Final report  

SciTech Connect (OSTI)

Increasing costs of energy and the development of lower cost microelectronics have created a growing market for energy management systems applied to commercial buildings. This report examines the spectrum of EMS available and how they are used in different types of commercial buildings. An informal survey of 197 commercial building owners provided additional information on EMS installed and the energy savings attributed to those systems. Evaluations were performed to identify types of EMS appropriate to specific types of commercial buildings.

Woody, A.W.

1986-02-01T23:59:59.000Z

226

Coupled robot-flow injection analysis system for fully automated determination of total polyphenols in olive oil  

Science Journals Connector (OSTI)

Coupled robot-flow injection analysis system for fully automated determination of total polyphenols in olive oil ...

Jose A. Garcia-Mesa; M. Dolores Luque de Castro; Miguel Valcarcel

1993-12-01T23:59:59.000Z

227

Building thermal envelope systems and materials (BTESM) progress report for DOE Office of Buildings Energy Research  

SciTech Connect (OSTI)

The Monthly Report of the Building Thermal Envelope Systems and Materials (BTESM) Program is a monthly update of both in-house ORNL projects and subcontract activities in the research areas of building materials, wall systems, foundations, roofs, and building diagnostics. Presentations are not stand-alone paragraphs every month. Their principal values are the short-time lapse between accomplishment and reporting and their evolution over a period of several months.

Burn, G. (comp.)

1990-10-01T23:59:59.000Z

228

Building Thermal Envelope Systems and Materials (BTESM) progress report for DOE Office of Buildings Energy Research  

SciTech Connect (OSTI)

The Monthly Report of the Building Thermal Envelope Systems and Materials (BTESM) Program is a monthly update of both in-house ORNL projects and subcontract activities in the research areas of building materials, wall systems, foundations, roofs, and building diagnostics. Presentations are not stand-alone paragraphs every month. Their principal values are the short-time lapse between accomplishment and reporting and their evolution over a period of several months.

Burn, G. (comp.)

1990-12-01T23:59:59.000Z

229

Building Thermal Envelope Systems and Materials (BTESM) progress report for DOE Office of Buildings Energy Research  

SciTech Connect (OSTI)

The Monthly Report of the Building Thermal Envelope Systems and Materials (BTESM) Program is a monthly update of both in-house ORNL projects and subcontract activities in the research areas of building materials, wall systems, foundations, roofs, building diagnostics, and research utilization and technology transfer. Presentations are not stand-alone paragraphs every month. Their principal values are the short-time lapse between accomplishment and reporting and their evolution over a period of several months.

Burn, G. (comp.)

1990-01-01T23:59:59.000Z

230

Basement Insulation Systems- Building America Top Innovation  

Broader source: Energy.gov [DOE]

This Building America Innovations profile describes Building America research on basement insulation, which identifies the wall installation methods and materials that perform best in terms of insulation and water resistance.

231

A Modular Building Controls Virtual Test Bed for the Integrations of Heterogeneous Systems  

SciTech Connect (OSTI)

This paper describes the Building Controls Virtual Test Bed (BCVTB) that is currently under development at Lawrence Berkeley National Laboratory. An earlier prototype linked EnergyPlus with controls hardware through embedded SPARK models and demonstrated its value in more cost-effective envelope design and improved controls sequences for the San Francisco Federal Building. The BCVTB presented here is a more modular design based on a middleware that we built using Ptolemy II, a modular software environment for design and analysis of heterogeneous systems. Ptolemy II provides a graphical model building environment, synchronizes the exchanged data and visualizes the system evolution during run-time. Our additions to Ptolemy II allow users to couple to Ptolemy II a prototype version of EnergyPlus,MATLAB/Simulink or other simulation programs for data exchange during run-time. In future work we will also implement a BACnet interface that allows coupling BACnet compliant building automation systems to Ptolemy II. We will present the architecture of the BCVTB and explain how users can add their own simulation programs to the BCVTB. We will then present an example application in which the building envelope and the HVAC system was simulated in EnergyPlus, the supervisory control logic was simulated in MATLAB/Simulink and Ptolemy II was used to exchange data during run-time and to provide realtime visualization as the simulation progresses.

Wetter, Michael; Wetter, Michael; Haves, Philip

2008-06-30T23:59:59.000Z

232

Development of control system to automate the PCB pin insertion process  

E-Print Network [OSTI]

This thesis describes the development of the control system that runs the automated pin insertion machine in a surface mount technology assembly line. The control system is divided into 2 subsystems viz. pin sorting and ...

Isaac, Rejin

2012-01-01T23:59:59.000Z

233

Implementation and design of a communication system of an agent-based automated substation  

Science Journals Connector (OSTI)

A substation system requires that communication be transmitted reliably, ... the communication system of an agent-based automated substation is introduced. The running principle is discussed ... realization of th...

Yong-jun Lin; Yu-tao Liu; Dan-hui Zhang

2006-12-01T23:59:59.000Z

234

A study of an embedded community network system in home automation  

Science Journals Connector (OSTI)

This article proposes an embedded system of home automation in a community network The system includes a home security monitor and a home energy monitor. The home security monitor uses sensors and micro switches ...

Chun-Liang Chen

2010-12-01T23:59:59.000Z

235

Development of Mechanical Systems for Automated Medical Slide Specimen Storage and Retrieval  

E-Print Network [OSTI]

and intriguing considering that improving medical systems can save the lives of patients. The Intelligent System and Automation Laboratory at the University of Kansas has created a prototype machine with the goal of making the process of medical slide specimen...

Wurtz, Joshua James

2014-05-31T23:59:59.000Z

236

Functions and Requirements and Specifications for Replacement of the Computer Automated Surveillance System (CASS)  

SciTech Connect (OSTI)

This functions, requirements and specifications document defines the baseline requirements and criteria for the design, purchase, fabrication, construction, installation, and operation of the system to replace the Computer Automated Surveillance System (CASS) alarm monitoring.

SCAIEF, C.C.

1999-12-16T23:59:59.000Z

237

Automated Design Methodology for Mechatronic Systems Using Bond Graphs and Genetic Programming  

E-Print Network [OSTI]

, allow free composition, and are efficient for classification and analysis of models, allowing rapidAutomated Design Methodology for Mechatronic Systems Using Bond Graphs and Genetic Programming University, zhangbai@egr.msu.edu Abstract This paper suggests an automated design methodology

Fernandez, Thomas

238

Automated Construction of Fast and Accurate System-Level Models For Wireless Sensor Networks  

E-Print Network [OSTI]

Automated Construction of Fast and Accurate System-Level Models For Wireless Sensor Networks Lan S are evaluated via simulation. Notably, one such automatically produced model outperforms the most advanced design decisions. The modeling work in this paper is part of a project on automated synthesis of sensor

Dick, Robert

239

Automated system for permeability and electrical conductivity of low-permeability reservoir rock  

SciTech Connect (OSTI)

An automated laboratory control and measurement system for liquid permeability and electrical conductivity of low permeability reservoir rock as a function of confining pressure has been constructed and tested. The system is controlled by a desktop computer with digital I/0, ADC and IEEE-488 interfaces. Computer programs and flow charts are presented for the automated system and for application of portions of the system to other laboratory experiments.

Jennings, J.B.; Raible, C.J.; Carroll, H.B. Jr.

1982-07-01T23:59:59.000Z

240

Application experience with the diaglog automated diagnostic system  

SciTech Connect (OSTI)

Operating experience over the last year with the DIAGLOG automated diagnostic system has shown that operating events at a 230 KV substation for selected line terminals can be monitored and diagnosed. DIAGLOG is a Diagnostic Logic System which has been applied to substation diagnostics under EPRI Project RP1359-20. Reporting data from an instrumented substation has been used to operate the diagnostic system when a significant event is reported. Lessons learned and the significance of monitor point selection are discussed. The use of maintenance alerts f or indicating when equipment is starting to operate out of specification as well as failure reports to tell when a misoperation has occurred are discussed. when a misoperation is detected, then the diagnostics can be asked to perform a troubleshooting procedure to identify what item has failed to operate correctly. Both primary and secondary relay operations are combined in the model logic, and near and remote events are recognized through monitoring of the carrier set activity.

Andre, B. [ANDTEK Inc. Huntsville, AL (United States); Smith, L. [Alabama Power, Birmingham, AL (United States)

1996-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Integrated Building Management System (IBMS) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Building Management System Building Management System (IBMS) Integrated Building Management System (IBMS) The U.S. Department of Energy (DOE) is currently conducting research into an integrated building management system (IBMS). Project Description This project seeks to develop an open integration framework that allows multivendor systems to interoperate seamlessly using internet protocols. The applicant will create an integrated control platform for implementing new integrated control strategies and to enable additional enterprise control applications, such as demand response. The project team seeks to develop several strategies that take advantage of the sensors and functionality of heating, ventilation, and air conditioning (HVAC); security; and information and communication technologies (ICT) subsystems;

242

A building life-cycle information system for tracking building performance metrics  

SciTech Connect (OSTI)

Buildings often do not perform as well in practice as expected during pre-design planning, nor as intended at the design stage. While this statement is generally considered to be true, it is difficult to quantify the impacts and long-term economic implications of a building in which performance does not meet expectations. This leads to a building process that is devoid of quantitative feedback that could be used to detect and correct problems both in an individual building and in the building process itself. One key element in this situation is the lack of a standardized method for documenting and communicating information about the intended performance of a building. This paper describes the Building Life-cycle Information System (BLISS); designed to manage a wide range of building related information across the life cycle of a building project. BLISS is based on the Industry Foundation Classes (IFC) developed by the International Alliance for Interoperability. A BLISS extension to th e IFC that adds classes for building performance metrics is described. Metracker, a prototype tool for tracking performance metrics across the building life cycle, is presented.

Hitchcock, R.J.; Piette, M.A.; Selkowitz, S.E.

1999-04-01T23:59:59.000Z

243

Benchmarking and Performance Based Rating System for Commercial Buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Benchmarking and Performance Based Rating System for Commercial Buildings Benchmarking and Performance Based Rating System for Commercial Buildings in India Speaker(s): Saket Sarraf Date: May 4, 2012 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Girish Ghatikar The Indian building sector has witnessed huge surge in interest in energy performance in the last decade. The 'intention' based codes like the national Energy Conservation Building Code (ECBC) and green building rating systems such as Leadership in Energy and Environment Design (LEED-India) and Green Rating for Integrated Habitat Assessment (GRIHA) have been the prime mechanisms to design and assess energy efficient buildings. However, they do not rate the 'achieved' energy performance of buildings over time or reward their performance through a continuous evaluation process.

244

Automated Surface Observing System (ASOS) General System Description  

E-Print Network [OSTI]

Generator System $ 4,300 135 $ 580,500 Hydrogen Fuel Cell $ 5,500 135 $ 742,500 4 #12;Life Cycle Cost;ACU Option Comparison Battery Bank to power Hydrogen Fuel Engine Generator the existing UPS Cell at 884 sites nationwide, normally at airports · System has two distinct subsystems: Field installed

245

Fault Detection and Diagnosis in Building HVAC Systems.  

E-Print Network [OSTI]

??Building HVAC systems account for more than 30% of annual energy consumption in United States. However, it has become apparent that only in a small… (more)

Najafi, Massieh

2010-01-01T23:59:59.000Z

246

Building America Webinar: Central Multifamily Water Heating Systems  

Broader source: Energy.gov [DOE]

This U.S. Department of Energy Building America webinar, Central Multifamily Water Heating Systems, will take place on January 21, 2015.

247

System/Building Tech Integration | Clean Energy | ORNL  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

System/Building Integration System/Building Integration SHARE System Building Technologies Integration ZEBRAlliance home The buildings industry encompasses numerous designers, builders, construction materials and components manufacturers, distributors, dealers, and other vendors and service providers. Whether coming together for new construction or retrofitting established structures, these stakeholders often face research limitations and challenges when integrating components, equipment, and systems. This is especially true for anything that is new. System/Building Integration provides the means for our industry partners to work out the wrinkles in their new products in low-risk, realistic test bed environments before market introduction. In ORNL's residential and light commercial building test beds, in addition to natural exposure to weather,

248

Meeting Minutes from Automated Home Energy Management System Expert Meeting  

Broader source: Energy.gov (indexed) [DOE]

Home Energy Management System Expert Meeting Home Energy Management System Expert Meeting October 1-2, 2009 AGENDA - Day 1 8:30 - 8:45 Welcome and Debriefing of Building America and Home Energy Management Research- Lew Pratsch, DOE 8:45 - 9:15 Utilities Trends- Smart Grid Projects and Integration With Home Controls - Mike Keesee, SMUD 9:15 - 9:45 Thoughts on Controls System Performance Requirements - Rich Brown, LBL 9:45 - 10:15 Efficiency Trends in Consumer Electronics - Kurtis McKenney, TIAX 10:15 - 10:30 Session Break 10:30 - 11:00 Cloud Computing (Web Data Computing, Data Storage) Trends - Troy Batterberry, Microsoft 11:00- 11:30 Cloud Computing (Web Data Computing, Data Storage) Trends - Tom Sly via Net Conference 11:30 - 12:00 Smart Appliance Trends / Home Area Network Trends - David Najewicz, GE

249

Development of discrete event system specification (DEVS) building performance models for building energy design  

Science Journals Connector (OSTI)

The discrete event system specification (DEVS) is a formalism for describing simulation models in a modular fashion. In this study, it is exploited by forming submodels that allow different professions involved in the building design process to work ... Keywords: DEVS, energy simulation in building design, modular BPS, stochastic occupant models

Huseyin Burak Gunay; Liam O'Brien; Rhys Goldstein; Simon Breslav; Azam Khan

2013-04-01T23:59:59.000Z

250

Technology Enablers for Next-Generation Economic Building Monitoring Systems  

E-Print Network [OSTI]

specific context for analysis. Primary duties include aggregating building data, managing measurement devices (loggers), and analyzing data for quality, diagnostics, and savings. Modern EMCS may encompass all of the subsystems. Simple monitoring systems... Control data to the logger Master Building Server Aggregate building data, manage measurement devices (loggers), analyze data for quality, savings, and unknowns Control network of local servers and loggers Large computer system with RDBMS and online...

Sweeney, J., Jr.; Culp, C.

2001-01-01T23:59:59.000Z

251

Building America Systems Integration Research Annual Report: FY 2012  

SciTech Connect (OSTI)

This document is the Building America FY2012 Annual Report, which includes an overview of the Building America Program activities and the work completed by the National Renewable Energy Laboratory and the Building America industry consortia (the Building America teams). The annual report summarizes major technical accomplishments and progress towards U.S. Department of Energy Building Technologies Program's multi-year goal of developing the systems innovations that enable risk-free, cost effective, reliable and durable efficiency solutions that reduce energy use by 30%-50% in both new and existing homes.

Gestwick, M.

2013-05-01T23:59:59.000Z

252

Automation of airlift scheduling for the upgraded command and control system of military airlift command  

E-Print Network [OSTI]

This report describes a conceptual design for automation of the scheduling of airlift activities as part of the current upgrade of the MAC C2 System. It defines the airlift scheduling problem in generic terms before reviewing ...

Simpson, R. W.

1984-01-01T23:59:59.000Z

253

Study on integrated automation system of traction substation for express railway lines  

Science Journals Connector (OSTI)

The structure and function of integrated automation system of traction substation for express electric railway lines developed by our university are discussed in this paper. The paper mainly describes the function installation of monitoring and communication ...

Gao Shibin; Chen Xiaochuan; Wang Qian; Wang Ren; Chen Weirong; Xiong Liebin

2002-11-01T23:59:59.000Z

254

Architecting global automation systems over a distributed multi-agent infrastructure  

Science Journals Connector (OSTI)

In this work we present an agent-based architecture for Global Automation Systems. The architecture follows a layered abstract model that allows decoupling design responsibilities, promotes high cohesion within layers and clearly emphasizes the environment. ...

Franco Guidi-Polanco; Claudio Cubillos; Giuseppe Menga

2005-06-01T23:59:59.000Z

255

Design and prototype of an automated system for commercially viable production using micro contact printing  

E-Print Network [OSTI]

This dissertation is a documentation of the thought process, its justification and the implementation details that went into prototyping a fully automated system employing Micro Contact Printing, an emerging technique for ...

Chauhan, Karan

2006-01-01T23:59:59.000Z

256

Automated material handling systems: an approach to robust layout planning of AMHS  

Science Journals Connector (OSTI)

The simulation-based layout planning of automated material handling systems (AMHS) for microelectronics and semiconductor manufacturing demands adequate simulation models. An approach for measuring and quantifying the AMHS layout performance of alternative ...

Roland Sturm; Joachim Seidelmann; Johann Dorner; Kevin Reddig

2003-12-01T23:59:59.000Z

257

Human-Automation Collaboration in Complex Multivariate Resource Allocation Decision Support Systems  

E-Print Network [OSTI]

In resource allocation problems for systems with moving planning horizons and significant uncertainty, typical of supervisory control environments, it is critical that some balance of human-automation collaboration be ...

Cummings, M.L.

2010-01-01T23:59:59.000Z

258

Building-Level Energy Management Systems (BLEMS) | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Emerging Technologies » Building-Level Energy Management Systems Emerging Technologies » Building-Level Energy Management Systems (BLEMS) Building-Level Energy Management Systems (BLEMS) The U.S. Department of Energy (DOE) is currently conducting research into building-level energy management systems (BLEMS). Project Description BLEMS provide an integrated plug-and-play capability for legacy energy management systems (EMSs), such as those based on X-10, Zigbee, 802.15, and newly developed EMS for buildings of any size. Project Partners Research is being undertaken by DOE, the University of Southern California, General Electric (GE) Global Research, and GE Consumer & Industrial Division. Project Goals The goal of this project is to develop practical solutions that bring together ad-hoc legacy energy management systems under a single, unified

259

Test Automation Test Automation  

E-Print Network [OSTI]

Test Automation Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2013 Mousavi: Test Automation #12;Test Automation Outline Test Automation Mousavi: Test Automation #12;Test Automation Why? Challenges of Manual Testing Test-case design: Choosing inputs

Mousavi, Mohammad

260

Increase energy efficiency in systems and buildings and improve indoor  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Increase energy efficiency in systems and buildings and improve indoor Increase energy efficiency in systems and buildings and improve indoor environment: How to validate comfort and energy reduction Speaker(s): Wouter Borsboom Date: December 8, 2009 - 12:00pm Location: 90-3122 TNO is a research institute which is active in the energy saving and indoor environment. We like to present our research, our goals and discuss the challenges and the opportunities for cooperation. Therefore we like to give a presentation about the following topic and we are also interested in a presentation of LBL and UC Berkeley. An important topic in the building industry is near zero energy buildings. Most countries in Europe implemented programs to advance this goal in one way or another. In near-zero energy buildings, the interaction between building and systems

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Cyber-physical energy systems: focus on smart buildings  

Science Journals Connector (OSTI)

Operating at the intersection of multiple sensing and control systems designed for occupant comfort, performability and operational efficiency, modern buildings represent a prototypical cyber-physical system with deeply coupled embedded sensing and networked ... Keywords: LEED, ZNEB, buildings, cyber-physical, embedded, energy management, energy metering, smart grid

Jan Kleissl; Yuvraj Agarwal

2010-06-01T23:59:59.000Z

262

Energy Saving in Office Building by Floor Integration System: Reducing  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Energy Saving in Office Building by Floor Integration System: Reducing Energy Saving in Office Building by Floor Integration System: Reducing Total Energy of HVAC and Lighting system using daylight Speaker(s): Yoshifumi Murakami Date: May 20, 2004 - 12:00pm Location: Bldg. 90 Seminar Host/Point of Contact: Naoya Motegi Information Technology that is featured by standard communication protocol like Lon Works, BACnet is very useful for managing building systems. Now we can collect much data quickly and easily and to analyze them in detail with this technology. Under the circumstances in that saving energy and reducing CO2 are required strongly, important thing is finding the effective information for building operation and control from collected data and the analysis of them. In our project, the floor integration controller that integrates the each building systems was proposed. It

263

Energy Consumption Analyses of Frequently-used HVAC System Types in High Performance Office Buildings.  

E-Print Network [OSTI]

??The high energy consumption of heating, ventilation and air-conditioning (HVAC) systems in commercial buildings is a hot topic. Office buildings, a typical building set of… (more)

Yan, Liusheng

2014-01-01T23:59:59.000Z

264

Indoor humidity and human health: part II--buildings and their systems  

E-Print Network [OSTI]

Northwest homes. Healthy Buildings: Proceeding of IAQ ’91,inside an HVAC system compatible with a healthy building?Healthy Buildings: Proceeding of IAQ ’91, September,

Arens, Edward A; Baughman, A.

1996-01-01T23:59:59.000Z

265

Theoretical Minimum Energy Use of a Building HVAC System  

E-Print Network [OSTI]

This paper investigates the theoretical minimum energy use required by the HVAC system in a particular code compliant office building. This limit might be viewed as the "Carnot Efficiency" for HVAC system. It assumes that all ventilation and air...

Tanskyi, O.

2011-01-01T23:59:59.000Z

266

Building energy modeling programs comparison Research on HVAC systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

energy modeling programs comparison Research on HVAC systems energy modeling programs comparison Research on HVAC systems simulation part Title Building energy modeling programs comparison Research on HVAC systems simulation part Publication Type Journal Year of Publication 2013 Authors Zhou, Xin, Da Yan, Tianzhen Hong, and Dandan Zhu Keywords Building energy modeling programs, comparison tests, HVAC system simulation, theory analysis Abstract Building energy simulation programs are effective tools for the evaluation of building energy saving and optimization of design. The fact that large discrepancies exist in simulated results when different BEMPs are used to model the same building has caused wide concern. Urgent research is needed to identify the main elements that contribute towards the simulation results. This technical report summarizes methodologies, processes, and the main assumptions of three building energy modeling programs (BEMPs) for HVAC calculations: EnergyPlus, DeST, and DOE-2.1E, and test cases are designed to analyze the calculation process in detail. This will help users to get a better understanding of BEMPs and the research methodology of building simulation. This will also help build a foundation for building energy code development and energy labeling programs.

267

An implementation of co-simulation for performance prediction of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

Developing an Integrated Building Design Tool by Couplingdesign energy efficient building systems in this complex setting, integrated

Trcka, Marija

2010-01-01T23:59:59.000Z

268

Substation automation -- a ``bottoms up`` approach  

SciTech Connect (OSTI)

The proliferation of multi-purpose intelligent electronic devices in substations brought the availability of abundant and often overlapping data at the substation. This data can be used for improving the operation and maintenance of the substations and the entire power system. The objective of substation automation is to use technology to gather, consolidate and utilize this data for increasing the efficiency of power system operation and maintenance. Often automation functions are developed and offered around the capabilities of the preferred hardware and software of the integrator. Emphasis is placed on hardware, software and communication protocols rather than need, methodology and application. This can result in over-automation with complex, expensive and ineffective systems, or under-automation that fails to achieve the user`s objectives. The objective is to select appropriate hardware, software and methodology to build the most cost effective system to get the desired results. This paper describes steps to ensure the successful implementation of substation automation.

Thomas, J. [General Electric, Malvern, PA (United States)

1996-10-01T23:59:59.000Z

269

System-Level Monitoring and Diagnosis of Building HVAC System.  

E-Print Network [OSTI]

??Heating, ventilation, and air conditioning (HVAC) is an indoor environmental technology that is extensively instrumented for large-scale buildings. Among all subsystems of buildings, the HVAC… (more)

Wu, Siyu

2013-01-01T23:59:59.000Z

270

Building America Case Study: Balancing Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet)  

SciTech Connect (OSTI)

In multifamily hydronic systems, temperature imbalance may be caused by undersized piping, improperly adjusted balancing valves, inefficient water temperature and flow levels, and owner/occupant interaction with the boilers, distribution and controls. The effects of imbalance include tenant discomfort, higher energy use intensity and inefficient building operation. This paper explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs. The research was conducted by The Partnership for Advanced Residential Retrofit (PARR) in conjunction with Elevate Energy. The team surveyed existing knowledge on cost-effective retrofits for optimizing distribution in typical multifamily hydronic systems, with the aim of identifying common situations and solutions, and then conducted case studies on two Chicago area buildings with known balancing issues in order to quantify the extent of temperature imbalance. At one of these buildings a booster pump was installed on a loop to an underheated wing of the building. This study found that unit temperature in a multifamily hydronic building can vary as much as 61 degrees F, particularly if windows are opened or tenants use intermittent supplemental heating sources like oven ranges. Average temperature spread at the building as a result of this retrofit decreased from 22.1 degrees F to 15.5 degrees F.

Not Available

2014-09-01T23:59:59.000Z

271

Automated diagnostics scoping study. Final report  

SciTech Connect (OSTI)

The objective of the Automated Diagnostics Scoping Study was to investigate the needs for diagnostics in building operation and to examine some of the current technologies in automated diagnostics that can address these needs. The study was conducted in two parts. In the needs analysis, the authors interviewed facility managers and engineers at five building sites. In the technology survey, they collected published information on automated diagnostic technologies in commercial and military applications as well as on technologies currently under research. The following describe key areas that the authors identify for the research, development, and deployment of automated diagnostic technologies: tools and techniques to aid diagnosis during building commissioning, especially those that address issues arising from integrating building systems and diagnosing multiple simultaneous faults; technologies to aid diagnosis for systems and components that are unmonitored or unalarmed; automated capabilities to assist cause-and-effect exploration during diagnosis; inexpensive, reliable sensors, especially those that expand the current range of sensory input; technologies that aid predictive diagnosis through trend analysis; integration of simulation and optimization tools with building automation systems to optimize control strategies and energy performance; integration of diagnostic, control, and preventive maintenance technologies. By relating existing technologies to perceived and actual needs, the authors reached some conclusions about the opportunities for automated diagnostics in building operation. Some of a building operator`s needs can be satisfied by off-the-shelf hardware and software. Other needs are not so easily satisfied, suggesting directions for future research. Their conclusions and suggestions are offered in the final section of this study.

Quadrel, R.W.; Lash, T.A.

1994-06-01T23:59:59.000Z

272

Energy Management Systems Package for Small Commercial Buildings  

Broader source: Energy.gov (indexed) [DOE]

EnMS (energy management EnMS (energy management systems) Package for Small Commercial Buildings Jessica Granderson Lawrence Berkeley National Laboratory JGranderson@lbl.gov 510.486.6792 April 4, 2013 2 | Building Technologies Office eere.energy.gov Purpose & Objectives Problem Statement: Small commercial buildings present two challenges for implementing energy efficiency strategies 1) high transaction cost relative to total savings 2) lack of personnel time or skill available for energy management

273

Engineering and Software Requirements of the Automated Building Commissioning Analysis Tool (ABCAT)  

E-Print Network [OSTI]

, Texas A&M University Mingsheng Liu, PI, University of Nebraska Frank Painter, Texas A&M University Gang Wang, University of Nebraska Energy Systems Laboratory Texas Engineering Experiment Station The Texas A&M University System...&M is David E. Claridge and the Project Manager is Malcolm Verdict. Prof. David Claridge, Prof. Mingsheng Liu of the University of Nebraska, Frank Painter, a Research Assistant at the ESL and Gang Wang, a Research Assistant at the University of Nebraska...

Claridge, D. E.; Liu, M.; Painter, F.; Wang, G.

2005-01-01T23:59:59.000Z

274

Ball State building massive geothermal system | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Ball State building massive geothermal system Ball State building massive geothermal system Ball State building massive geothermal system March 19, 2010 - 5:47pm Addthis Workers drill boreholes for a geothermal heating and cooling system at Ball State University’s campus in Muncie, Ind. | Photo courtesy of Ball State University Workers drill boreholes for a geothermal heating and cooling system at Ball State University's campus in Muncie, Ind. | Photo courtesy of Ball State University Paul Lester Communications Specialist for the Office of Energy Efficiency and Renewable Energy Ball State University is building America's largest ground source district geothermal heating and cooling system. The new operation will save the school millions of dollars, slash greenhouse gases and create jobs. The project will also "expand how America will define the use of

275

Ball State building massive geothermal system | Department of Energy  

Broader source: Energy.gov (indexed) [DOE]

Ball State building massive geothermal system Ball State building massive geothermal system Ball State building massive geothermal system March 19, 2010 - 5:47pm Addthis Workers drill boreholes for a geothermal heating and cooling system at Ball State University’s campus in Muncie, Ind. | Photo courtesy of Ball State University Workers drill boreholes for a geothermal heating and cooling system at Ball State University's campus in Muncie, Ind. | Photo courtesy of Ball State University Paul Lester Communications Specialist, Office of Energy Efficiency and Renewable Energy Ball State University is building America's largest ground source district geothermal heating and cooling system. The new operation will save the school millions of dollars, slash greenhouse gases and create jobs. The project will also "expand how America will define the use of

276

High Performance Commercial Building Systems William L. Carroll  

E-Print Network [OSTI]

Efficiency and Renewable Energy, Building Technologies Program of the U.S. Department of Energy underHigh Performance Commercial Building Systems William L. Carroll Ernest Orlando Lawrence Berkeley.2 ­ Retrofit Tools Task 2 HPBCS E2P2.2T3 LBNL - 57775 California Energy Commission Public Interest Energy

277

Paul Mathew Staff Scientist, Commercial Building Systems Group  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Mathew Mathew Staff Scientist, Commercial Building Systems Group A Datapalooza for Measured Building Performance: The DOE Buildings Performance Database Lawrence Berkeley National Laboratory November 4, 2013 BPD Team Rich Brown Claudine Custudio Laurel Dunn Paul Mathew John Mejia Andrea Mercado Michael Sohn Travis Walter Software partner: Sponsor: ..... analytical revolution upending the way campaigns political are run in the 21st century... the smartest campaigns now believe they know who you will vote for even before you do... Energy Benchmarking Policies (selected) * California - AB1103 requires benchmarking of all commercial buildings at time of lease or sale. - Executive order S-20-04 requires benchmarking of all state buildings. - SB1 requires buildings applying for solar incentives to benchmark

278

Automated fiber pigtailing machine  

DOE Patents [OSTI]

The Automated Fiber Pigtailing Machine (AFPM) aligns and attaches optical fibers to optoelectronic (OE) devices such as laser diodes, photodiodes, and waveguide devices without operator intervention. The so-called pigtailing process is completed with sub-micron accuracies in less than 3 minutes. The AFPM operates unattended for one hour, is modular in design and is compatible with a mass production manufacturing environment. This machine can be used to build components which are used in military aircraft navigation systems, computer systems, communications systems and in the construction of diagnostics and experimental systems. 26 figs.

Strand, O.T.; Lowry, M.E.

1999-01-05T23:59:59.000Z

279

Disposable and removable nucleic acid extraction and purification cartridges for automated flow-through systems  

DOE Patents [OSTI]

Removable cartridges are used on automated flow-through systems for the purpose of extracting and purifying genetic material from complex matrices. Different types of cartridges are paired with specific automated protocols to concentrate, extract, and purifying pathogenic or human genetic material. Their flow-through nature allows large quantities sample to be processed. Matrices may be filtered using size exclusion and/or affinity filters to concentrate the pathogen of interest. Lysed material is ultimately passed through a filter to remove the insoluble material before the soluble genetic material is delivered past a silica-like membrane that binds the genetic material, where it is washed, dried, and eluted. Cartridges are inserted into the housing areas of flow-through automated instruments, which are equipped with sensors to ensure proper placement and usage of the cartridges. Properly inserted cartridges create fluid- and air-tight seals with the flow lines of an automated instrument.

Regan, John Frederick

2014-09-09T23:59:59.000Z

280

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond  

E-Print Network [OSTI]

Automated Testing of HVAC Systems for Commissioning Tim Salsbury and Rick Diamond Lawrence Berkeley of the commissioning of HVAC systems. The approach is based on software that generates a sequence of test signals for new and retrofit projects. Introduction The performance of many HVAC systems is limited more by poor

Diamond, Richard

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Evaluation of Transit Operations: Data Applications of Tri-Met's Automated Bus Dispatching System  

E-Print Network [OSTI]

Evaluation of Transit Operations: Data Applications of Tri-Met's Automated Bus Dispatching System Dispatch System Tri-Met's BDS was installed in 1997 and became fully operational in 1998. Its main features Transportation System (APTS) technology has been motivated by transit providers' desire to improve service

Bertini, Robert L.

282

Operation Diagnosis for Buildings Connecting Building Management Systems with Energy Management Systems  

E-Print Network [OSTI]

Reducing energy consumption of buildings is a good contribution to protect the environment and to reduce costs. The first and most important step to operate a building most efficiently is to make aware of most of the technical parameters. Connecting...

Mehler, G.

2008-01-01T23:59:59.000Z

283

Applications of HVAC System Utilizing Building Thermal Mass in Japan  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Applications of HVAC System Utilizing Building Thermal Mass in Japan Applications of HVAC System Utilizing Building Thermal Mass in Japan Speaker(s): Katsuhiro Miura Date: January 27, 2012 - 10:00am Location: 90-3122 Seminar Host/Point of Contact: Michael Wetter Buildings have a large thermal capacity and it affects much on building thermal load for the HVAC system. The thermal mass can be utilized also to control the thermal load by storing thermal energy before HVAC operation. There are two ways to store thermal energy. One is by operating the HVAC system and the other is by natural ventilation, mainly at night. The latter could be combined with daily HVAC operation as a hybrid ventilation. Thermal mass storage is useful to decrease the hourly peak load and the daily thermal load and can be used for both cooling and heating purpose.

284

Generative Design Systems Applied to Low-Energy Buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Generative Design Systems Applied to Low-Energy Buildings Generative Design Systems Applied to Low-Energy Buildings Speaker(s): Maria Luisa de Oliveira Gama Caldas Date: March 15, 2012 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: Paul Mathew Generative Design Systems (GDS) represent a step beyond parametric models, integrating design goals, building simulations and shape generation. In this seminar, present and future research projects on the application of different GDS to low-energy buildings are discussed. The software GENE_ARCH integrates energy simulations with multicriteria search methods such as pareto genetic algorithms, to locate acceptable alternatives that move the current design towards performance goals set by the user. DIVA, a system that integrates parametric geometrical modeling with Radiance, Daysim and

285

Building America Webinar: Central Multifamily Water Heating Systems  

Broader source: Energy.gov [DOE]

Hosted by DOE's Building America program, this webinar will focus on the effective use of central heat pump water heaters (HPWHs) and control systems to reduce the energy use in hot water distribution.

286

NREL: News Feature - Solar System Tops Off Efficient NREL Building  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Solar System Tops Off Efficient NREL Building September 29, 2010 Photo of the sun reflecting off of a solar panel on a roof. Enlarge image More than 1,800 solar panels are being...

287

Scalable Distributed Automation System: Scalable Real-time Decentralized Volt/VAR Control  

SciTech Connect (OSTI)

GENI Project: Caltech is developing a distributed automation system that allows distributed generators—solar panels, wind farms, thermal co-generation systems—to effectively manage their own power. To date, the main stumbling block for distributed automation systems has been the inability to develop software that can handle more than 100,000 distributed generators and be implemented in real time. Caltech’s software could allow millions of generators to self-manage through local sensing, computation, and communication. Taken together, localized algorithms can support certain global objectives, such as maintaining the balance of energy supply and demand, regulating voltage and frequency, and minimizing cost. An automated, grid-wide power control system would ease the integration of renewable energy sources like solar power into the grid by quickly transmitting power when it is created, eliminating the energy loss associated with the lack of renewable energy storage capacity of the grid.

None

2012-03-01T23:59:59.000Z

288

Monitoring Buildings with Energy Management and Control Systems  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

6 6 Monitoring Buildings with Energy Management and Control Systems Monitoring and evaluation are important parts of all energy-efficiency programs. With the increasing regulatory requirements for verification of demand-side management program savings and continued development of more innovative financing mechanisms, the ability to substantiate claims of energy savings using measured data takes on added importance. Although expensive, the accurate monitoring of energy consumption and building operations is a necessary part of conservation savings analysis. Energy management and control systems (EMCSs), intended for building operations and control functions, already contain most of the same equipment usually installed for energy monitoring and can often be used for

289

Image Recognition System for Automated Lighting Retrofit Assessment  

E-Print Network [OSTI]

, and K. Baugh, ?Spectral Identification of Lighting Type and Character,? Sensors, vol. 10, pp. 3961-3988, 2010. (3) L. Halonen, E. Tetri, and P. Bhusal, ?Guidebook on Energy Efficient Electric Lighting for Buildings,? Espoo, Finland: Dept. Elect. Eng...

Venable, K.; Bhatia, D.; Coverick, R.; Gutierrez, C.; Knight, J.; McGarry, D.; McGee, K.; Smith, Z.; Terrill, T. J.; Vanderford, B.; Weiser, R.; Wightman, K.; Rasmussen, B. P.

2013-01-01T23:59:59.000Z

290

Precursor systems analyses of automated highway systems. Activity area C. Automated check-out. Final report, September 1993-November 1994  

SciTech Connect (OSTI)

The activity evaluates potential automatic-to-manual transition scenarios in terms of relative feasibility, safety, cost, and social implications. The check-out alternatives range from minimal testing of the operator and the vehicle to extensive testing of the operator and vehicle. The vehicle functions analysis presents a summary of functions that are critical to safe manual operation and proposes several options for validation. Two possible check-out processes are discussed, one intended for AHS lanes dedicated to automated traffic, and one intended for mixed mode lanes in which AHS and non-AHS vehicles are traveling. The transition to manual control will involve preparing the driver to resume manual operation prior to release of vehicle functions. Proposed tasks which could be used to determine that the driver is ready to receive control of the automated vehicle are examined.

Mangarelli, F.; Cochran, A.; Craig, D.; Michael, B.; Halseth, M.

1995-05-01T23:59:59.000Z

291

Performance of thermal distribution systems in large commercial buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Performance of thermal distribution systems in large commercial buildings Performance of thermal distribution systems in large commercial buildings Title Performance of thermal distribution systems in large commercial buildings Publication Type Journal Article LBNL Report Number LBNL-44331 Year of Publication 2002 Authors Xu, Tengfang T., François Rémi Carrié, Darryl J. Dickerhoff, William J. Fisk, Jennifer A. McWilliams, Duo Wang, and Mark P. Modera Journal Energy and Buildings Volume 34 Start Page Chapter Pagination 215-226 Abstract This paper presents major findings of a field study on the performance of five thermal distribution systems in four large commercial buildings. The five systems studied are typical single-duct or dual-duct constant air volume (CAV) systems and variable air volume (VAV) systems, each of which serves an office building or a retail building with floor area over 2,000 m2. The air leakage from ducts are reported in terms of effective leakage area (ELA) at 25 Pa reference pressure, the ASHRAE-defined duct leakage class, and air leakage ratios. The specific ELAs ranged from 0.7 to 12.9 cm2 per m2 of duct surface area, and from 0.1 to 7.7 cm2 per square meter of floor area served. The leakage classes ranged from 34 to 757 for the five systems and systems sections tested. The air leakage ratios are estimated to be up to one-third of the fan- supplied airflow in the constant-air-volume systems. The specific ELAs and leakage classes indicate that air leakage in large commercial duct systems varies significantly from system to system, and from system section to system section even within the same thermal distribution system. The duct systems measured are much leakier than the ductwork specified as "unsealed ducts" by ASHRAE. Energy losses from supply ducts by conduction (including convection and radiation) are found to be significant, on the scale similar to the losses induced by air leakage in the duct systems. The energy losses induced by leakage and conduction suggest that there are significant energy-savings potentials from duct-sealing and insulation practice in large commercial buildings

292

Automated Analysis of Fault-Tolerance in Distributed Systems Scott D. Stoller y  

E-Print Network [OSTI]

Automated Analysis of Fault-Tolerance in Distributed Systems #3; Scott D. Stoller y Computer satisfy in speci#12;ed failure scenarios. Our analysis method is to compute, for each failure scenario for which the user speci#12;ed a fault-tolerance requirement, an MFG representing the system's communication

Schneider, Fred B.

293

World Automation Congress 2010 TSI Press. USING A FUZZY LOGIC CONTROL SYSTEM FOR AN XPILOT  

E-Print Network [OSTI]

World Automation Congress © 2010 TSI Press. USING A FUZZY LOGIC CONTROL SYSTEM FOR AN XPILOT COMBAT {ahubley, parker}@conncoll.edu ABSTRACT--Fuzzy logic controllers provide a means of reasoning in uncertain systems. In this paper, we use fuzzy logic to develop a more versatile controller that can deal

Parker, Gary B.

294

EFFICIENT VEHICLE TRACKING AND CLASSIFICATION FOR AN AUTOMATED TRAFFIC SURVEILLANCE SYSTEM  

E-Print Network [OSTI]

surveillance system needs to detect vehicles and classify them if possible. Generating vehicle trajectoriesEFFICIENT VEHICLE TRACKING AND CLASSIFICATION FOR AN AUTOMATED TRAFFIC SURVEILLANCE SYSTEM Amol to detect the pose of a vehicle in the 3D world. This information is used in a model-based vehicle detection

Nicolescu, Mircea

295

THE LHC EXPERIMENT CONTROL SYSTEM: ON THE PATH TO FULL AUTOMATION  

E-Print Network [OSTI]

THE LHC EXPERIMENT CONTROL SYSTEM: ON THE PATH TO FULL AUTOMATION C. Gaspar, F. Alessio, L. Cardoso, Rutherford Appleton Laboratory, Chilton, Didcot, OX11 0QX, UK Abstract LHCb is a large experiment at the LHC are based on the PVSS SCADA System complemented by a control Framework developed in common for the 4 LHC

Paris-Sud XI, Université de

296

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings  

E-Print Network [OSTI]

Utilizing Passive Ventilation to Complement HVAC Systems in Enclosed Buildings Tom Rogg REU Student to assist HVAC has the potential to significantly reduce life cycle cost and energy consumption and electrical system that will tie thermostats to controlled valves in the actual HVAC system. Based on results

Mountziaris, T. J.

297

Model Predictive Control for Energy Efficient Buildings  

E-Print Network [OSTI]

automation system “Automated Logic Web Control. ” In theto the campus through the Automated Logics Web Control (ALC)using WebCTRL developed by Automated Logic Corporation. The

Ma, Yudong

2012-01-01T23:59:59.000Z

298

Buildings Energy Data Book: 5.5 Thermal Distribution Systems  

Buildings Energy Data Book [EERE]

5 5 Typical Commercial Building Thermal Energy Distribution Design Load Intensities (Watts per SF) Distribution System Fans Other Central System Supply Fans Cooling Tower Fan Central System Return Fans Air-Cooled Chiller Condenser Fan 0.6 Terminal Box Fans 0.5 Exhaust Fans (2) Fan-Coil Unit Fans (1) Condenser Fans 0.6 Packaged or Split System Indoor Blower 0.6 Pumps Chilled Water Pump Condenser Water Pump Heating Water Pump Note(s): Source(s): 0.1 - 0.2 0.1 - 0.2 1) Unducted units are lower than those with some ductwork. 2) Strong dependence on building type. BTS/A.D. Little, Energy Consumption Characteristics of Commercial Building HVAC Systems, Volume II:Thermal Distribution, Auxiliary Equipment, and Ventilation, Oct. 1999, Table 3-1, p. 3-6. 0.3 - 1.0 0.1 - 0.3 0.1 - 0.4

299

ENERGY STAR Building Upgrade Manual Chapter 8: Air Distribution Systems |  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

8: Air Distribution 8: Air Distribution Systems Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In This Section Campaigns Commercial building design Communications resources Energy management guidance Financial resources Portfolio Manager Products and purchasing Recognition Research and reports Service and product provider (SPP) resources Success stories Target Finder

300

Home Network Technologies and Automating Demand Response  

E-Print Network [OSTI]

potential role of home automation networks in implementinghow existing and future home automation systems may providehome networks" and "home automation" are frequently used

McParland, Charles

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Modeling the Energy Use of a Connected and Automated Transportation System (Poster)  

SciTech Connect (OSTI)

Early research points to large potential impacts of connected and automated vehicles (CAVs) on transportation energy use - dramatic savings, increased use, or anything in between. Due to a lack of suitable data and integrated modeling tools to explore these complex future systems, analyses to date have relied on simple combinations of isolated effects. This poster proposes a framework for modeling the potential energy implications from increasing penetration of CAV technologies and for assessing technology and policy options to steer them toward favorable energy outcomes. Current CAV modeling challenges include estimating behavior change, understanding potential vehicle-to-vehicle interactions, and assessing traffic flow and vehicle use under different automation scenarios. To bridge these gaps and develop a picture of potential future automated systems, NREL is integrating existing modeling capabilities with additional tools and data inputs to create a more fully integrated CAV assessment toolkit.

Gonder, J.; Brown, A.

2014-07-01T23:59:59.000Z

302

Automated Measurement and Signaling Systems for the Transactional Network  

Broader source: Energy.gov [DOE]

The Transactional Network Project is a multi-lab activity funded by the U.S. Department of Energy’s Building Technologies Office. The project team included staff from Lawrence Berkeley National Laboratory, Pacific Northwest National Laboratory, and Oak Ridge National Laboratory. The team designed, prototyped, and tested a transactional network (TN) platform to support energy, operational, and financial transactions between any networked entities (equipment, organizations, buildings, grid, etc.). This document describes the agents and applications developed by the LBNL team, and associated tests of the applications.

303

A Buildings Module for the Stochastic Energy Deployment System  

SciTech Connect (OSTI)

The U.S. Department of Energy (USDOE) is building a new long-range (to 2050) forecasting model for use in budgetary and management applications called the Stochastic Energy Deployment System (SEDS), which explicitly incorporates uncertainty through its development within the Analytica(R) platform of Lumina Decision Systems. SEDS is designed to be a fast running (a few minutes), user-friendly model that analysts can readily run and modify in its entirety through a visual programming interface. Lawrence Berkeley National Laboratory is responsible for implementing the SEDS Buildings Module. The initial Lite version of the module is complete and integrated with a shared code library for modeling demand-side technology choice developed by the National Renewable Energy Laboratory (NREL) and Lumina. The module covers both commercial and residential buildings at the U.S. national level using an econometric forecast of floorspace requirement and a model of building stock turnover as the basis for forecasting overall demand for building services. Although the module is fundamentally an engineering-economic model with technology adoption decisions based on cost and energy performance characteristics of competing technologies, it differs from standard energy forecasting models by including considerations of passive building systems, interactions between technologies (such as internal heat gains), and on-site power generation.

Lacommare, Kristina S H; Marnay, Chris; Stadler, Michael; Borgeson, Sam; Coffey, Brian; Komiyama, Ryoichi; Lai, Judy

2008-05-15T23:59:59.000Z

304

“Turn-Key” Open Source Software Solutions for Energy Management of Small to Medium Sized Buildings (DE-FOA-0000822)  

Broader source: Energy.gov [DOE]

Closed Total DOE Funding: $3 million This FOA seeks to develop a “turn key” Building Automation System using Open-Source software and architecture specifically tailored to small and medium buildings to advance opportunities for energy efficiency in this sector.

305

Comparison of Building Energy Modeling Programs: HVAC Systems  

E-Print Network [OSTI]

Comparison of Building Energy Modeling Programs: BuildingComparison of Building Energy Modeling Programs: HVACassumptions of three building energy modeling programs (

Zhou, Xin

2014-01-01T23:59:59.000Z

306

Active Integrated Perimeter Building Systems | Department of...  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

sensor data, but sharing the data with faade and HVAC control systems to implement load reduction or demand-side ventilation strategies is difficult because the data are...

307

Building a Smarter Distribution System in Pennsylvania  

Broader source: Energy.gov (indexed) [DOE]

Development of an advanced distribution management system (DMS) software is at the heart of the project. The DMS monitors and controls all of the smart devices being installed...

308

Building Hierarchical Grid Storage Using the GFARM Global File System  

E-Print Network [OSTI]

-sharing service and the GFARM grid file system; then, it introduces our hybrid architecture. Section 4 gives Work One of the major goals of grid infrastructures is to transparently provide access to comBuilding Hierarchical Grid Storage Using the GFARM Global File System and the JUXMEM Grid Data

Paris-Sud XI, Université de

309

Automated Demand Response and Commissioning  

SciTech Connect (OSTI)

This paper describes the results from the second season of research to develop and evaluate the performance of new Automated Demand Response (Auto-DR) hardware and software technology in large facilities. Demand Response (DR) is a set of activities to reduce or shift electricity use to improve the electric grid reliability and manage electricity costs. Fully-Automated Demand Response does not involve human intervention, but is initiated at a home, building, or facility through receipt of an external communications signal. We refer to this as Auto-DR. The evaluation of the control and communications must be properly configured and pass through a set of test stages: Readiness, Approval, Price Client/Price Server Communication, Internet Gateway/Internet Relay Communication, Control of Equipment, and DR Shed Effectiveness. New commissioning tests are needed for such systems to improve connecting demand responsive building systems to the electric grid demand response systems.

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Bourassa, Norman

2005-04-01T23:59:59.000Z

310

Chapter 7 - Active Solar Systems in Buildings  

Science Journals Connector (OSTI)

Abstract This chapter deals with the review of solar active thermal systems. They are discussed from a point of view of different technological concepts, mode of operation, heating needs, complexity of their design, and construction. Different classifications of these systems are also presented. The focus is put on system configuration depending on its heating functions. Some consideration is given to the structure of solar heating systems, methods of energy storage, and cooperation with alternative, auxiliary, or peak heat sources, including heat pumps. Flat-plate, evacuated tube, unglazed, and some other types of solar collectors and their main components are described. Advantages and disadvantages of the main types of solar collectors are analyzed. Methods of determining energy efficiency of solar collectors and graphical interpretation of their thermal characteristics are presented in order to show how different collector types can be evaluated for their use in buildings in different weather conditions and applications. Use of photovoltaics (PV) in buildings is also considered. Physical fundamentals of the internal PV effect are presented. Technologies of solar PV cells and systems are described along with different operating modes. The stress is put on technologies applied in buildings. It is emphasized that the dual nature of building elements, with coherency between architecture and energy production (PV systems and solar heating), will be standard in solar self-energy sufficient buildings. To give a full picture of solar active systems applied in buildings, solar cooling technologies are also discussed. It is underlined that sorption cooling technologies may help in solving a problem of working fluid overheating in the collector loop and in storage encountered in solar combisystems (i.e., space heating plus hot water heating).

Dorota Chwieduk

2014-01-01T23:59:59.000Z

311

Modelica-based Modeling and Simulation to Support Research and Development in Building Energy and Control Systems  

E-Print Network [OSTI]

applied earlier for building energy modeling applicationstowards building HVAC system modeling and simulation. Forof equation-based modeling for building systems. We believe

Wetter, Michael

2010-01-01T23:59:59.000Z

312

Open Automated Demand Response Technologies for Dynamic Pricing and Smart Grid  

E-Print Network [OSTI]

for Automated Demand Response in Commercial Buildings. ” In2010. “Open Automated Demand Response Dynamic Pricing2009. “Open Automated Demand Response Communications

Ghatikar, Girish

2010-01-01T23:59:59.000Z

313

Demonstration of Datacenter Automation Software and Hardware (DASH) at the California Franchise Tax Board  

E-Print Network [OSTI]

of Datacenter Automation Software and Hardware (DASH) at theof Datacenter Automation Software and Hardware (DASH) at theprotocol for building automation and control networks. It is

Bell, Geoffrey C.

2010-01-01T23:59:59.000Z

314

Automated Demand Response Technologies and Demonstration in New York City using OpenADR  

E-Print Network [OSTI]

EMCS Vendor and Product Automated Logic Control RemoteBuildings Integrator, Automated Logic Corporation’s WebCTRLIntegrator (EBI), Automated Logic Corporation’s WebCTRL® ,

Kim, Joyce Jihyun

2014-01-01T23:59:59.000Z

315

Thermal Performance of Ferrocement Green Building System  

Science Journals Connector (OSTI)

System must not only cope with strengths and flexibility requirements, but the insulation value is of high importance. In summer heat must be kept outside as much as possible. The great demands of electric power ...

Wail N. Al-Rifaie; Waleed K. Ahmed…

2014-01-01T23:59:59.000Z

316

Building dependability arguments for software intensive systems  

E-Print Network [OSTI]

A method is introduced for structuring and guiding the development of end-to-end dependability arguments. The goal is to establish high-level requirements of complex software-intensive systems, especially properties that ...

Seater, Robert Morrison

2009-01-01T23:59:59.000Z

317

Building interactive systems using unconventional electronics  

Science Journals Connector (OSTI)

Many interactive systems use "conventional" silicon- based sensors and electronics that limit their functionality and scalability. Organic, amorphous inorganic, and other "unconventional" electronics are ideal for applications that require mechanical ... Keywords: fabrication, large-area, organic light- emitting diode, piezoelectric

John Sarik; Ioannis Kymissis

2011-01-01T23:59:59.000Z

318

Review: Business Process Implementation: Building Workflow Systems  

Science Journals Connector (OSTI)

......flouting control systems and list characteristics of computer fraudsters: these...Philip Sargent Laser-Scan Intranets ?? Intranets: The Surf Within James Cimino...into the need for a secure intranet. His facts and figures on......

Philip Sargent

1998-01-01T23:59:59.000Z

319

A Fully Automated Fault-tolerant System for Distributed Video Processing and Off-site Replication  

E-Print Network [OSTI]

A Fully Automated Fault-tolerant System for Distributed Video Processing and Off-site Replication been a failure-prone tedious operation with an operator needed to babysit the processing and off-site, off-site replication, fault-tolerance, grid, educational research. 1. INTRODUCTION In different fields

Wisconsin at Madison, University of

320

Manual of Security Requirements for the Classified Automated Information System Security Program  

Broader source: Directives, Delegations, and Requirements [Office of Management (MA)]

This Manual provides specific instructions and delineates the requirements to ensure the graded security of classified information entrusted to the Department of Energy (DOE) that is processed, stored, transferred, or accessed on Automated Information Systems (AISs) and AIS networks. Canceled by DOE M 471.2-2.

1994-07-15T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Towards automation of low standardized logistic processes by use of cyber physical robotic systems (CPRS)  

Science Journals Connector (OSTI)

Global logistics networks have an increasing demand for handling of general cargo. Particularly, huband-spoke networks requires a lot of handling actions in order to realize benefits in comparison to point-to-point networks. The use of automation technologies ... Keywords: cooperative robotics, cyber physical systems, human computer interaction, human machine interface, industrial robots, virtual reality

Bernd Scholz-Reiter; Moritz Rohde; Stefan Kunaschk; Michael Lütjen

2011-11-01T23:59:59.000Z

322

DEVELOPMENT OF AN ULTRASONIC NDT SYSTEM FOR AUTOMATED IN-SITU INSPECTION OF WIND TURBINE BLADES  

E-Print Network [OSTI]

of a wind turbine, including turbine blades, tower, gears, generator bearings etc. [2]. However, due to highDEVELOPMENT OF AN ULTRASONIC NDT SYSTEM FOR AUTOMATED IN- SITU INSPECTION OF WIND TURBINE BLADES Abington, Cambridge, CB21 6AL, UK bic@brunel.ac.uk ABSTRACT It is crucial to maintain wind turbine blades

Boyer, Edmond

323

Automated Transportation Management System (ATMS) V2.0 logistics module PBI acceptance criteria  

SciTech Connect (OSTI)

This document defines the acceptance criteria for the Automated Transportation Management System V2.0 Logistics Module Performance Based Incentive (PBI). This acceptance criteria will be the primary basis for the generation of acceptance test procedures. The purpose of this document is to define the minimum criteria that must be fulfilled to guarantee acceptance of the Logistics Module.

Weidert, R.S.

1995-02-28T23:59:59.000Z

324

Deadlock Avoidance Policies for Automated Manufacturing Systems Using Finite State Automata  

E-Print Network [OSTI]

Automata Spyros Reveliotis and Ahmed Nazeem1 1S. Reveliotis is with the School of Industrial & Systems product lines and more customized product offerings [22]. Indeed, since the beginning of the industrial revolution, automation has been at the core of the mass-production concept and practices, enabling activities

Reveliotis, Spiridon "Spyros"

325

Beyond Commissioning: The Role of Automation  

SciTech Connect (OSTI)

This article takes a brief look at the benefits of commissioning and describes a vision of the future where most of the objectives of commissioning will be accomplished automatically by capabilities built into the building systems themselves. Commissioning will become an activity that's performed continuously rather than periodically, and only repairs requiring replacement or overhaul of equipment will require manual intervention. The article then identifies some of the technologies that will be needed to realize this vision and ends with a call for all involved in the enterprise of building commissioning and automation to embrace and dedicate themselves to a future of automated commissioning.

Brambley, Michael R.; Katipamula, Srinivas

2005-02-01T23:59:59.000Z

326

An automated vision-based method for rapid 3D energy performance modeling of existing buildings using thermal and digital imagery  

Science Journals Connector (OSTI)

Abstract Modeling the energy performance of existing buildings enables quick identification and reporting of potential areas for building retrofit. However, current modeling practices of using energy simulation tools do not model the energy performance of buildings at their element level. As a result, potential retrofit candidates caused by construction defects and degradations are not represented. Furthermore, due to manual modeling and calibration processes, their application is often time-consuming. Current application of 2D thermography for building diagnostics is also facing several challenges due to a large number of unordered and non-geo-tagged images. To address these limitations, this paper presents a new computer vision-based method for automated 3D energy performance modeling of existing buildings using thermal and digital imagery captured by a single thermal camera. First, using a new image-based 3D reconstruction pipeline which consists of Graphic Processing Unit (GPU)-based Structure-from-Motion (SfM) and Multi-View Stereo (MVS) algorithms, the geometrical conditions of an existing building is reconstructed in 3D. Next, a 3D thermal point cloud model of the building is generated by using a new 3D thermal modeling algorithm. This algorithm involves a one-time thermal camera calibration, deriving the relative transformation by forming the Epipolar geometry between thermal and digital images, and the MVS algorithm for dense reconstruction. By automatically superimposing the 3D building and thermal point cloud models, 3D spatio-thermal models are formed, which enable the users to visualize, query, and analyze temperatures at the level of 3D points. The underlying algorithms for generating and visualizing the 3D spatio-thermal models and the 3D-registered digital and thermal images are presented in detail. The proposed method is validated for several interior and exterior locations of a typical residential building and an instructional facility. The experimental results show that inexpensive digital and thermal imagery can be converted into ubiquitous reporters of the actual energy performance of existing buildings. The proposed method expedites the modeling process and has the potential to be used as a rapid and robust building diagnostic tool.

Youngjib Ham; Mani Golparvar-Fard

2013-01-01T23:59:59.000Z

327

Building America Webinar: Retrofitting Central Space Conditioning Strategies for Multifamily Buildings- Steam Systems, Retrofit Measure Packages, Hydronic Systems  

Broader source: Energy.gov [DOE]

This presentation is included in the July 16, 2014, Building America webinar, and provides information about best practices, costs, and savings associated with optimizing steam and hydronic systems through increased main line air venting, replacing radiator vents, improving circulation pump efficiency, and upgrading boiler control systems.

328

Building embedded systems with embedded DSLs  

Science Journals Connector (OSTI)

We report on our experiences in synthesizing a fully-featured autopilot from embedded domain-specific languages (EDSLs) hosted in Haskell. The autopilot is approximately 50k lines of C code generated from 10k lines of EDSL code and includes control laws, ... Keywords: embedded domain specific languages, embedded systems

Patrick C. Hickey, Lee Pike, Trevor Elliott, James Bielman, John Launchbury

2014-08-01T23:59:59.000Z

329

A toolkit for building earth system models  

SciTech Connect (OSTI)

An earth system model is a computer code designed to simulate the interrelated processes that determine the earth's weather and climate, such as atmospheric circulation, atmospheric physics, atmospheric chemistry, oceanic circulation, and biosphere. I propose a toolkit that would support a modular, or object-oriented, approach to the implementation of such models.

Foster, I.

1993-03-01T23:59:59.000Z

330

A toolkit for building earth system models  

SciTech Connect (OSTI)

An earth system model is a computer code designed to simulate the interrelated processes that determine the earth`s weather and climate, such as atmospheric circulation, atmospheric physics, atmospheric chemistry, oceanic circulation, and biosphere. I propose a toolkit that would support a modular, or object-oriented, approach to the implementation of such models.

Foster, I.

1993-03-01T23:59:59.000Z

331

Co-Simulation of Building Energy and Control Systems with the Building Controls Virtual Test Bed  

SciTech Connect (OSTI)

This article describes the implementation of the Building Controls Virtual Test Bed (BCVTB). The BCVTB is a software environment that allows connecting different simulation programs to exchange data during the time integration, and that allows conducting hardware in the loop simulation. The software architecture is a modular design based on Ptolemy II, a software environment for design and analysis of heterogeneous systems. Ptolemy II provides a graphical model building environment, synchronizes the exchanged data and visualizes the system evolution during run-time. The BCVTB provides additions to Ptolemy II that allow the run-time coupling of different simulation programs for data exchange, including EnergyPlus, MATLAB, Simulink and the Modelica modelling and simulation environment Dymola. The additions also allow executing system commands, such as a script that executes a Radiance simulation. In this article, the software architecture is presented and the mathematical model used to implement the co-simulation is discussed. The simulation program interface that the BCVTB provides is explained. The article concludes by presenting applications in which different state of the art simulation programs are linked for run-time data exchange. This link allows the use of the simulation program that is best suited for the particular problem to model building heat transfer, HVAC system dynamics and control algorithms, and to compute a solution to the coupled problem using co-simulation.

Wetter, Michael

2010-08-22T23:59:59.000Z

332

Energy-Efficient Building HVAC Control Using Hybrid System LBMPC  

E-Print Network [OSTI]

Improving the energy-efficiency of heating, ventilation, and air-conditioning (HVAC) systems has the potential to realize large economic and societal benefits. This paper concerns the system identification of a hybrid system model of a building-wide HVAC system and its subsequent control using a hybrid system formulation of learning-based model predictive control (LBMPC). Here, the learning refers to model updates to the hybrid system model that incorporate the heating effects due to occupancy, solar effects, outside air temperature (OAT), and equipment, in addition to integrator dynamics inherently present in low-level control. Though we make significant modeling simplifications, our corresponding controller that uses this model is able to experimentally achieve a large reduction in energy usage without any degradations in occupant comfort. It is in this way that we justify the modeling simplifications that we have made. We conclude by presenting results from experiments on our building HVAC testbed, which s...

Aswani, Anil; Taneja, Jay; Krioukov, Andrew; Culler, David; Tomlin, Claire

2012-01-01T23:59:59.000Z

333

Ontology Development for Low-Energy Building Embedded Commissioning  

E-Print Network [OSTI]

This paper presents the results of initial work in developing an ontology for improving information exchange and automation in building system commissioning practices. In our previous research dealing with the derivation of product models from...

Lee, K. J.; Akin, O.; Akinci, B.; Garrett, J.; Bushby, S.

334

Training and refresher training of specialists in the field of modern automated process control systems for power stations  

Science Journals Connector (OSTI)

We consider problems pertinent to training and postgraduate refresher training of specialists in the field of automated process control systems built around software and hardware systems having a network hiera...

Yu. S. Tverskoi; E. K. Arakelyan; S. I. Kuznetsov

2006-11-01T23:59:59.000Z

335

Toward an Automated Design Method for Multi-Domain Dynamic Systems Using Bond Graphs and Genetic Programming  

E-Print Network [OSTI]

of models, permitting rapid determination of various types of acceptability or feasibility of candidate1 Toward an Automated Design Method for Multi-Domain Dynamic Systems Using Bond Graphs and Genetic Abstract This paper describes a unified and automated design method for synthesizing designs for multi

Hu, Jianjun

336

Total and Peak Energy Consumption Minimization of Building HVAC Systems Using Model Predictive Control  

E-Print Network [OSTI]

inputs. The idea of modeling building thermal behavior usingThe detail of building thermal modeling is pre- sented in [Modeling and optimal control algorithm design for hvac systems in energy efficient buildings,’’

Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2012-01-01T23:59:59.000Z

337

Architectural Building Blocks for Plug-and-Play System Design  

E-Print Network [OSTI]

Architectural Building Blocks for Plug-and-Play System Design Shangzhu Wang, George S. Avrunin semantics. Our approach is also integrated with design-time verification to provide feedback about with each other. Given the com- plexity of the behavior that is being described and the large design space

Avrunin, George S.

338

Justification to remove 333 Building fire suppression system  

SciTech Connect (OSTI)

Justification to remove the 333 Building fire suppression system is provided. The Maximum Possible Fire Loss (MPFL) is provided (approximately $800K), potential radiological and toxicological impacts from a postulated fire are discussed, Life Safety Code issues are addressed, and coordination with the Hanford Fire Department is assured.

Benecke, M.W.

1995-12-04T23:59:59.000Z

339

HVAC & Building Management Control System Energy Efficiency Replacements  

SciTech Connect (OSTI)

The project objective was the replacement of an aging, un-repairable HVAC system which has grown inefficient and a huge energy consumer with low energy and efficient HVAC units, and installation of energy efficient building control technologies at City's YMCA Community Center.

Hernandez, Adriana

2012-09-21T23:59:59.000Z

340

Automated Demand Response and Commissioning  

E-Print Network [OSTI]

Fully-Automated Demand Response Test in Large Facilities14in DR systems. Demand Response using HVAC in Commercialof Fully Automated Demand Response in Large Facilities”

Piette, Mary Ann; Watson, David S.; Motegi, Naoya; Bourassa, Norman

2005-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Integrated Energy Systems (IES) for Buildings: A Market Assessment  

SciTech Connect (OSTI)

Integrated Energy Systems (IES) combine on-site power or distributed generation technologies with thermally activated technologies to provide cooling, heating, humidity control, energy storage and/or other process functions using thermal energy normally wasted in the production of electricity/power. IES produce electricity and byproduct thermal energy onsite, with the potential of converting 80 percent or more of the fuel into useable energy. IES have the potential to offer the nation the benefits of unprecedented energy efficiency gains, consumer choice and energy security. It may also dramatically reduce industrial and commercial building sector carbon and air pollutant emissions and increase source energy efficiency. Applications of distributed energy and Combined heat and power (CHP) in ''Commercial and Institutional Buildings'' have, however, been historically limited due to insufficient use of byproduct thermal energy, particularly during summer months when heating is at a minimum. In recent years, custom engineered systems have evolved incorporating potentially high-value services from Thermally Activated Technologies (TAT) like cooling and humidity control. Such TAT equipment can be integrated into a CHP system to utilize the byproduct heat output effectively to provide absorption cooling or desiccant humidity control for the building during these summer months. IES can therefore expand the potential thermal energy services and thereby extend the conventional CHP market into building sector applications that could not be economically served by CHP alone. Now more than ever, these combined cooling, heating and humidity control systems (IES) can potentially decrease carbon and air pollutant emissions, while improving source energy efficiency in the buildings sector. Even with these improvements over conventional CHP systems, IES face significant technological and economic hurdles. Of crucial importance to the success of IES is the ability to treat the heating, ventilation, air conditioning, water heating, lighting, and power systems loads as parts of an integrated system, serving the majority of these loads either directly or indirectly from the CHP output. The CHP Technology Roadmaps (Buildings and Industry) have focused research and development on a comprehensive integration approach: component integration, equipment integration, packaged and modular system development, system integration with the grid, and system integration with building and process loads. This marked change in technology research and development has led to the creation of a new acronym to better reflect the nature of development in this important area of energy efficiency: Integrated Energy Systems (IES). Throughout this report, the terms ''CHP'' and ''IES'' will sometimes be used interchangeably, with CHP generally reserved for the electricity and heat generating technology subsystem portion of an IES. The focus of this study is to examine the potential for IES in buildings when the system perspective is taken, and the IES is employed as a dynamic system, not just as conventional CHP. This effort is designed to determine market potential by analyzing IES performance on an hour-by-hour basis, examining the full range of building types, their loads and timing, and assessing how these loads can be technically and economically met by IES.

LeMar, P.

2002-10-29T23:59:59.000Z

342

Integrating fuel cell power systems into building physical plants  

SciTech Connect (OSTI)

This paper discusses the integration of fuel cell power plants and absorption chillers to cogenerate chilled water or hot water/steam for all weather air conditioning as one possible approach to building system applications. Absorption chillers utilize thermal energy in an absorption based cycle to chill water. It is feasible to use waste heat from fuel cells to provide hydronic heating and cooling. Performance regimes will vary as a function of the supply and quality of waste heat. Respective performance characteristics of fuel cells, absorption chillers and air conditioning systems will define relationships between thermal and electrical load capacities for the combined systems. Specifically, this paper develops thermodynamic relationships between bulk electrical power and cooling/heating capacities for combined fuel cell and absorption chiller system in building applications.

Carson, J. [KCI Technologies, Inc., Hunt Valley, MD (United States)

1996-12-31T23:59:59.000Z

343

Lateral Control of Heavy Vehicles for Automated Systems  

E-Print Network [OSTI]

system tracks the desired front wheel steering angle (? 1 ) exactly, then the sliding variable will asymptotically converg to a ball,

Hingwe, Pushkar; Wang, Jen-Yu; Tai, Meihua; Tomizuka, Masayoshi

2003-01-01T23:59:59.000Z

344

Steam System Balancing and Tuning for Multifamily Residential Buildings, Chicago, Illinois (Fact Sheet), Building America Case Study: Technology Solutions for New and Existing Homes, Building Technologies Office (BTO)  

Broader source: Energy.gov (indexed) [DOE]

Steam System Balancing Steam System Balancing and Tuning for Multifamily Residential Buildings Chicago, Illinois PROJECT INFORMATION Project Name: Steam System Balancing and Tuning for Multifamily Residential Buildings Location: Chicago, IL Partners: Partnership for Advanced Residential Retrofit www.gastechnology.org Building Component: Steam heating distribution system and controls Application: Retrofit; Multifamily Year Tested: 2011-2012 Applicable Climate Zone(s): Cold humid continental PERFORMANCE DATA Cost of Energy Efficiency Measure (including labor): $9,000 on average Projected Energy Savings: 10.2% heating savings Chicago's older multifamily housing stock is primarily heated by centrally metered steam or hydronic systems. Often, significant temperature differentials

345

Co-simulation of innovative integrated HVAC systems in buildings  

E-Print Network [OSTI]

Canada: International Building Perfor- mance SimulationExternal coupling between building energy simulation andexternal coupling of building energy and air ow modeling

Trcka, Marija

2010-01-01T23:59:59.000Z

346

Build, Own, Operate and Maintain (BOOM) Boiler Systems  

E-Print Network [OSTI]

Build, Own, Operate and Maintain (BOOM) Boiler Systems Tom Henry, Annstrong Service, Inc. Overview: The article addresses the growing trend in outsourcing boiler equipment, installation, operation, maintenance and ownership by large.... In most cases, thennal, electric and air energy systems are not considered "core" assets resulting in the need to find "other" solutions to providing the needed energy. ? Reduced staffing has resulted in fewer experienced and knowledgeable boiler...

Henry, T.

347

Energy Signal Tool for Decision Support in Building Energy Systems  

SciTech Connect (OSTI)

A prototype energy signal tool is demonstrated for operational whole-building and system-level energy use evaluation. The purpose of the tool is to give a summary of building energy use which allows a building operator to quickly distinguish normal and abnormal energy use. Toward that end, energy use status is displayed as a traffic light, which is a visual metaphor for energy use that is either substantially different from expected (red and yellow lights) or approximately the same as expected (green light). Which light to display for a given energy end use is determined by comparing expected to actual energy use. As expected, energy use is necessarily uncertain; we cannot choose the appropriate light with certainty. Instead, the energy signal tool chooses the light by minimizing the expected cost of displaying the wrong light. The expected energy use is represented by a probability distribution. Energy use is modeled by a low-order lumped parameter model. Uncertainty in energy use is quantified by a Monte Carlo exploration of the influence of model parameters on energy use. Distributions over model parameters are updated over time via Bayes' theorem. The simulation study was devised to assess whole-building energy signal accuracy in the presence of uncertainty and faults at the submetered level, which may lead to tradeoffs at the whole-building level that are not detectable without submetering.

Henze, G. P.; Pavlak, G. S.; Florita, A. R.; Dodier, R. H.; Hirsch, A. I.

2014-12-01T23:59:59.000Z

348

Building.  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

System ITER LHD Magnetic Confinement Neutral Beam Plasma Confinement Systems Primary Heat Transfer System Remote Handling Systems Shield Module Steady-State (Tokamak) Reactor...

349

The Study on Building of Virtual Reality System in Large Surface Coal Mine  

Science Journals Connector (OSTI)

The building of virtual reality system for the opencast mine is a complicated and systemic project. The building process of virtual system includes data collection, GIS geodabase, model designing and raster te...

Baoying Ye; Nisha Bao; Zhongke Bai

2011-01-01T23:59:59.000Z

350

Building Technologies Office: Residential Buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Residential Buildings Residential Buildings to someone by E-mail Share Building Technologies Office: Residential Buildings on Facebook Tweet about Building Technologies Office: Residential Buildings on Twitter Bookmark Building Technologies Office: Residential Buildings on Google Bookmark Building Technologies Office: Residential Buildings on Delicious Rank Building Technologies Office: Residential Buildings on Digg Find More places to share Building Technologies Office: Residential Buildings on AddThis.com... About Take Action to Save Energy Partner With DOE Activities Technology Research, Standards, & Codes Popular Residential Links Success Stories Previous Next Warming Up to Pump Heat. Lighten Energy Loads with System Design. Cut Refrigerator Energy Use to Save Money. Tools EnergyPlus Whole Building Simulation Program

351

Automation of the design of a telescopic zoom system  

Science Journals Connector (OSTI)

This paper discusses the theoretical bases of the construction and computation of the parameters of a telescopic zoom system. A mathematical model and algorithm has been developed,...

Van Luen, Nguen

2013-01-01T23:59:59.000Z

352

Distributed Generation System Characteristics and Costs in the Buildings Sector  

Gasoline and Diesel Fuel Update (EIA)

Distributed Generation System Distributed Generation System Characteristics and Costs in the Buildings Sector August 2013 Independent Statistics & Analysis www.eia.gov U.S. Department of Energy Washington, DC 20585 U.S. Energy Information Administration | Distributed Generation System Characteristics and Costs in the Buildings Sector i This report was prepared by the U.S. Energy Information Administration (EIA), the statistical and analytical agency within the U.S. Department of Energy. By law, EIA's data, analyses, and forecasts are independent of approval by any other officer or employee of the United States Government. The views in this report therefore should not be construed as representing those of the U.S. Department of Energy or other Federal agencies.

353

Titan's New Build Attracts Magnetic Systems Research Impossible Until Now  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Titan's New Build Attracts Magnetic Systems Research Impossible Until Now Titan's New Build Attracts Magnetic Systems Research Impossible Until Now November 01, 2013 Researchers using Titan are studying the behavior of magnetic systems by simulating nickel atoms as they reach their Curie temperature-the threshold between order (right) and disorder (left) when atoms spin into random magnetic directions of fluctuating magnetic strengths, causing the material to lose its magnetism. As simple as magnets seemed during school science lessons (opposites attract, likes repel), improving the performance of magnetic materials and creating new alloys is so complicated Markus Eisenbach, computational scientist at Oak Ridge National Laboratory, has been waiting for a computer that can perform as many as twenty quadrillion calculations per second to

354

Install renewable energy systems | ENERGY STAR Buildings & Plants  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Install renewable energy systems Install renewable energy systems Secondary menu About us Press room Contact Us Portfolio Manager Login Facility owners and managers Existing buildings Commercial new construction Industrial energy management Small business Service providers Service and product providers Verify applications for ENERGY STAR certification Design commercial buildings Energy efficiency program administrators Commercial and industrial program sponsors Associations State and local governments Federal agencies Tools and resources Training In this section Learn the benefits Get started Use Portfolio Manager Save energy Stamp out energy waste Find cost-effective investments Engage occupants Purchase energy-saving products Put computers to sleep Get help from an expert Take a comprehensive approach Install renewable energy systems

355

Digital Control for Automation  

Science Journals Connector (OSTI)

GREATER YIELDS OF BETTER QUALITY PRODUCTS at reduced costs: That's one way to look at automations goal. And among instruments for automation are data reduction systems (others: continuous process analyzers, computer elements, and control mechanisms). ...

1956-04-02T23:59:59.000Z

356

Research and Application of FlexRay High-Speed Bus on Transformer Substation Automation System  

Science Journals Connector (OSTI)

Through researching FlexRay high-speed bus technology, this paper auxiliary builds electric power system hardware interface standards and software application layer standards. Meanwhile, this paper also realizes ...

Hui Li; Hao Zhang; Daogang Peng

2010-01-01T23:59:59.000Z

357

Performance of thermal distribution systems in large commercial buildings  

E-Print Network [OSTI]

Energy Efficiency and Renewable Energy, Office of BuildingEnergy Efficiency and Renewable Energy, Office of Building

Xu, T.

2011-01-01T23:59:59.000Z

358

Automation and Accountability in Decision Support System Interface Design  

E-Print Network [OSTI]

When the human element is introduced into decision support system design, entirely new layers of social and ethical issues emerge but are not always recognized as such. This paper discusses those ethical and social impact ...

Cummings, M. L.

2006-01-01T23:59:59.000Z

359

Advanced Retro-commissioning Technology: Predictive Energy Optimization (PEO) and Automated Demand Response for Commercial Building HVAC  

Broader source: Energy.gov [DOE]

Lead Performer: BuildingIQ, Inc. – Foster City, CaliforniaPartners: Department of General Services – Washington, DCDOE Funding: $1,767,138Cost Share: $1,767,138Project Term: October 2014 –...

360

Lateral control of articulated vehicles for automated highway systems under uncertainty in vehicle parameters  

E-Print Network [OSTI]

OF CONTENTS Vl LIST OF TABLES LIST OF FIGURES V111 CHAPTER I INTRODUCTION CHAPTER II ARTICULATED VEHICLE MODELING 2. 1 22 23 2. 4 25 26 Introduction . Longitudinal Model of the Tractor-Semitrailer . . . Modeling the Tractor-Semitrailer Linkage... FOR AUTOMATED HIGHWAY SYSTEMS . . . . . . . . . . . . . . . . . . . . 29 4. 1 4. 2 4. 3 Road Reference Frame . Steering Control of Tractor-Semitrailer Vehicles . . . 4, 2. 1 Controller Design . . 4. 2. 2 Simulation Results . . . Steering and Independent...

Daud, Omar

2012-06-07T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Efficient Detection on Stochastic Faults in PLC Based Automated Assembly Systems With Novel Sensor Deployment and Diagnoser Design  

E-Print Network [OSTI]

In this dissertation, we proposed solutions on novel sensor deployment and diagnoser design to efficiently detect stochastic faults in PLC based automated systems First, a fuzzy quantitative graph based sensor deployment was called upon to model...

Wu, Zhenhua

2012-07-16T23:59:59.000Z

362

Technology & System Specifications | The Better Buildings Alliance  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

& System Specifications & System Specifications Activities Technology Solutions Teams Public Sector Teams Market Solutions Teams Technology & System Specifications The Better Buildings Alliance Technology Solutions Teams develop specifications for you to customize and use to obtain quotes for high-efficiency products and services. Collective support for these product and performance specifications demonstrates a market need to manufacturers and leads to greater product availability, higher quality, and more competitive pricing. Get started by clicking below. Available Specifications Sign your support for the Wireless Meter Challenge and review the specification The wireless meter challenge has been launched to catalyze the development of low cost metering solutions. Meters are an integral component of energy

363

Automated Grid Disruption Response System: Robust Adaptive Topology Control (RATC)  

SciTech Connect (OSTI)

GENI Project: The RATC research team is using topology control as a mechanism to improve system operations and manage disruptions within the electric grid. The grid is subject to interruption from cascading faults caused by extreme operating conditions, malicious external attacks, and intermittent electricity generation from renewable energy sources. The RATC system is capable of detecting, classifying, and responding to grid disturbances by reconfiguring the grid in order to maintain economically efficient operations while guaranteeing reliability. The RATC system would help prevent future power outages, which account for roughly $80 billion in losses for businesses and consumers each year. Minimizing the time it takes for the grid to respond to expensive interruptions will also make it easier to integrate intermittent renewable energy sources into the grid.

None

2012-03-01T23:59:59.000Z

364

Automated Proactive Techniques for Commissioning Air-Handling Units  

SciTech Connect (OSTI)

Many buildings today use sophisticated building automation systems (BASs) to manage a wide and varied range of building systems. Although the capabilities of the BASs seem to have increased over time, many buildings still are not properly commissioned, operated or maintained. Lack of or improper commissioning, the inability of the building operators to grasp the complex controls, and lack of proper maintenance leads to inefficient operations and reduced lifetimes of the equipment. If regularly scheduled manual maintenance or re-commissioning practices are adopted, they can be expensive and time consuming. Automated proactive commissioning and diagnostic technologies address two of the main barriers to commissioning: cost and schedules. Automated proactive continuous commissioning tools can reduce both the cost and time associated with commissioning, as well as enhance the persistence of commissioning fixes. In the long run, automation even offers the potential for automatically correcting problems by reconfiguring controls or changing control algorithms dynamically. This paper will discuss procedures and processes that can be used to automate and continuously commission the economizer operation and outdoor-air ventilation systems of an air-handling unit.

Katipamula, Srinivas (BATTELLE (PACIFIC NW LAB)); Brambley, Michael R. (BATTELLE (PACIFIC NW LAB)); Luskay, Larry (Portland Energy Conservation, Inc.)

2003-08-30T23:59:59.000Z

365

Distributed Generation System Characteristics and Costs in the Buildings  

Gasoline and Diesel Fuel Update (EIA)

1.6 mb) 1.6 mb) Appendix A - Photovoltaic (PV) Cost and Performance Characteristics for Residential and Commercial Applications (1.0 mb) Appendix B - The Cost and Performance of Distributed Wind Turbines, 2010-35 (0.5 mb) Distributed Generation System Characteristics and Costs in the Buildings Sector Release date: August 7, 2013 Distributed generation in the residential and commercial buildings sectors refers to the on-site generation of energy, often electricity from renewable energy systems such as solar photovoltaics (PV) and small wind turbines. Many factors influence the market for distributed generation, including government policies at the local, state, and federal level, and project costs, which vary significantly depending on time, location, size, and application.

366

Gaussian Process Modeling: Applications to Building Systems and Algorithmic  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Gaussian Process Modeling: Applications to Building Systems and Algorithmic Gaussian Process Modeling: Applications to Building Systems and Algorithmic Challenges Speaker(s): Victor M. Zavala Date: November 5, 2013 - 12:00pm - 1:00pm Location: 90-3122 Seminar Host/Point of Contact: Mary Ann Piette Michael Sohn We review applications and algorithmic challenges of Gaussian Process (GP) modeling. GP is a powerful and flexible uncertainty quantification and data analysis technique that enables the construction of complex models without the need to specify algebraic relationships between variables. This is done by working directly in the space of the kernel or covariance matrix. In addition, it derives from a Bayesian framework and, as such, it naturally provides predictive probability distributions. We describe how these features can be exploited in Measurement and Verification (M&V) tasks and

367

The Freight Shuttle System: Automated-Secure Trade  

E-Print Network [OSTI]

the same volume) #12;HDD Truck vs. FSS (CO2 required to service the same volume) #12;Next Steps · Finalize footprint guide way ­ To be built within existing highway ROW The Freight Shuttle System 24/7 operations transportation #12;#12;#12;#12;Port of Entry Security #12;Ciudad Juarez El Paso Scan-in-motion Scan

368

Development, Operation, and Results From the Texas Automated Buoy System  

E-Print Network [OSTI]

of the Gulf of Mexico Coastal Ocean Observing System (GCOOS) regional association and the primary source of near-surface current measurements in the northwestern Gulf of Mexico. This article describes the origin of Angolan crude, exploded and caught fire while lightering its cargo about 60 nautical miles south

369

A Data and Knowledge Management System for Intelligent Buildings  

E-Print Network [OSTI]

words: Intelligent building; Assessment; Methodology; Information system 1. INTRODUCTION It is the development and application of modern technologies in the areas of information, communication, materials, and machinery in the construction... Future, Vol.VIII-6-3 management of IBs. It is the authors? initiative to put forward an integrated methodology for lifecycle information management and knowledge utilization of IBs. The methodology will be described by using a novel prototype based...

Hong, J.; Chen, Z.; Li, H.; Xu, Q.

2006-01-01T23:59:59.000Z

370

FORTRAN M as a language for building earth system models  

SciTech Connect (OSTI)

FORTRAN M is a small set of extensions to FORTRAN 77 that supports a modular or object-oriented approach to the development of parallel programs. In this paper, I discuss the use of FORTRAN M as a tool for building earth system models on massively parallel computers. I hypothesize that the use of FORTRAN M has software engineering advantages and outline experiments that we are conducting to investigate this hypothesis.

Foster, I.

1992-01-01T23:59:59.000Z

371

FORTRAN M as a language for building earth system models  

SciTech Connect (OSTI)

FORTRAN M is a small set of extensions to FORTRAN 77 that supports a modular or object-oriented approach to the development of parallel programs. In this paper, I discuss the use of FORTRAN M as a tool for building earth system models on massively parallel computers. I hypothesize that the use of FORTRAN M has software engineering advantages and outline experiments that we are conducting to investigate this hypothesis.

Foster, I.

1992-12-31T23:59:59.000Z

372

Automated system for x-ray absorption spectroscopy of nanoparticle nucleation and growth  

SciTech Connect (OSTI)

X-ray absorption spectroscopy (XAS) is a useful tool for studying nanoparticle synthesis and growth. Described here is a system for automating synthesis and data collection, allowing time-resolved XAS measurements at a synchrotron to be accurately combined with measurements made under identical conditions elsewhere, and promising the ability to use XAS with experiments in combinatorial chemistry. The primary components of this system are a commercial parallel processor and a custom flow cell. The system has been used to collect data on the synthesis of iron oxides from iron(II) acetylacetonate.

Calvin, S.; Carpenter, E.E.; Cestone, V.; Kurihara, L.K.; Harris, V.G.; Brown, E.C. [Naval Research Lab, Code 6360, Washington, DC 20375 (United States); Sarah Lawrence College, 1 Mead Way, Bronxville, New York 10708 (United States)

2005-01-01T23:59:59.000Z

373

Implementing effect of energy efficiency supervision system for government office buildings and large-scale public buildings in China  

Science Journals Connector (OSTI)

The Chinese central government released a document to initiate a task of energy efficiency supervision system construction for government office buildings and large-scale public buildings in 2007, which marks the overall start of existing buildings energy efficiency management in China with the government office buildings and large-scale public buildings as a breakthrough. This paper focused on the implementing effect in the demonstration region all over China for less than one year, firstly introduced the target and path of energy efficiency supervision system, then described the achievements and problems during the implementing process in the first demonstration provinces and cities. A certain data from the energy efficiency public notice in some typical demonstration provinces and cities were analyzed statistically. It can be concluded that different functional buildings have different energy consumption and the average energy consumption of large-scale public buildings is too high in China compared with the common public buildings and residential buildings. The obstacles need to be overcome afterward were summarized and the prospects for the future work were also put forward in the end.

Jing Zhao; Yong Wu; Neng Zhu

2009-01-01T23:59:59.000Z

374

Design and Optimization of Control Strategies and Parameters by Building and System Simulation  

E-Print Network [OSTI]

temperatures have been tested and analyzed within simulation calculations. SIMULATION MODEL Building Model The part of the building considered for this study is modeled using the TRNSYS Type 56 multi-zone building model [3]. The model consists of 13... is integrated into the TRNSYS building model [4]. System Model The detailed model of the peripheric systems, the occupancy and load schedules of the building and the control strategies is built using the appropriate types from the model library of TRNSYS...

Baumann, O.

2003-01-01T23:59:59.000Z

375

Honeywell Modular Automation System Computer Software Documentation for the Magnesium Hydroxide Precipitation Process  

SciTech Connect (OSTI)

The purpose of this Computer Software Document (CSWD) is to provide configuration control of the Honeywell Modular Automation System (MAS) in use at the Plutonium Finishing Plant (PFP) for the Magnesium Hydroxide Precipitation Process in Rm 230C/234-5Z. The magnesium hydroxide process control software Rev 0 is being updated to include control programming for a second hot plate. The process control programming was performed by the system administrator. Software testing for the additional hot plate was performed per PFP Job Control Work Package 2Z-00-1703. The software testing was verified by Quality Control to comply with OSD-Z-184-00044, Magnesium Hydroxide Precipitation Process.

STUBBS, A.M.

2001-06-25T23:59:59.000Z

376

Comparison of Control Strategies for Energy Efficient Building HVAC Systems  

E-Print Network [OSTI]

transfer in rooms in the modelica buildings library. [18] A.Building models are first captured in Modelica [1]to leverage Modelica’s rich building component library and

Maasoumy, Mehdi; Sangiovanni-Vincentelli, Alberto

2014-01-01T23:59:59.000Z

377

A Buildings Module for the Stochastic Energy Deployment System  

E-Print Network [OSTI]

F.W. Dodge 1991: Building Stock Database Methodology andEnd-Use Flow Maps for the Buildings Sector, D.B. Belzer,N ATIONAL L ABORATORY A Buildings Module for the Stochastic

Marnay, Chris

2008-01-01T23:59:59.000Z

378

Co-simulation for performance prediction of integrated building and HVAC systems -An analysis of solution  

E-Print Network [OSTI]

Co-simulation for performance prediction of integrated building and HVAC systems - An analysis performance simulation of buildings and heating, ventilation and air- conditioning (HVAC) systems can help, heating, ventilation and air-conditioning (HVAC) systems are responsible for 10%-60% of the total building

379

SU?FF?T?109: Automation of Monte Carlo Simulations For A Proton Therapy System  

Science Journals Connector (OSTI)

Purpose: To develop a code system to automate the processes associated with Monte Carlo simulations of a clinical proton therapy system. Method and Materials: A software system was developed that accepts a clinical prescription (beam range range modulation and field size) and generates a complete Monte Carlo simulation input file that includes all major components in the M. D. Anderson passively scattered treatment head plus one of several user?selectable phantoms. The simulations are automatically submitted to a 130 dual?CPU cluster. Post processing scripts were also developed to analyze the simulation results and generate required configuration data for the Varian Eclipse treatment planning system. Quality assurance procedures such as design inspection unit test incremental integration test regression test and integration test were performed to ensure the code system produces correct results. The code system was written in mainly C language with some shell scripts and it runs on the LINUX operating system. Results: A code system has been developed to automatically generate MCNPX input files run simulations and perform post?processing of simulation results for a proton therapy system. The code system has been used to simulate dose profiles and generate required data for commissioning the M. D. Anderson proton therapy system. Over one thousand dose profiles were generated for different beam configurations by the code system in two months. Example beam data will be presented. Conclusion: The automated Monte Carlo code system has proved to be a useful tool for simulations of clinical applications in proton therapy. It allows for rapid modeling of proton therapy systems and the results of this study suggest that data from Monte Carlo simulations will play an increasingly prominent role in proton therapy projects i.e. pre?clinical design commissioning studies and routine clinical tasks.

Y Zheng; J Fontenot; N Koch

2006-01-01T23:59:59.000Z

380

Innovative System and Method for Monitoring Energy Efficiency in Buildings  

Science Journals Connector (OSTI)

Improving energy efficiency (EE) in buildings may significantly reduce...@lisee, for achieving energy efficiency in buildings (households, officies, campus, data centers, etc. ... devices, locally estimating indo...

Grazia Fattoruso; Saverio De Vito; Ciro Di Palma; Girolamo Di Francia

2014-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


382

Development of an automated Red Light Violation Detection System (RLVDS) for Indian vehicles  

E-Print Network [OSTI]

Integrated Traffic Management Systems (ITMS) are now implemented in different cities in India to primarily address the concerns of road-safety and security. An automated Red Light Violation Detection System (RLVDS) is an integral part of the ITMS. In our present work we have designed and developed a complete system for generating the list of all stop-line violating vehicle images automatically from video snapshots of road-side surveillance cameras. The system first generates adaptive background images for each camera view, subtracts captured images from the corresponding background images and analyses potential occlusions over the stop-line in a traffic signal. Considering round-the-clock operations in a real-life test environment, the developed system could successfully track 92% images of vehicles with violations on the stop-line in a "Red" traffic signal.

Saha, Satadal; Nasipuri, Mita; Basu, Dipak Kumar

2010-01-01T23:59:59.000Z

383

Building GHGs National Inventory Systems | Open Energy Information  

Open Energy Info (EERE)

GHGs National Inventory Systems GHGs National Inventory Systems Jump to: navigation, search Name Building GHGs National Inventory Systems - Capacity Development for National GHG´s Inventories in Non-Annex I Countries Agency/Company /Organization Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ) GmbH Sector Climate Focus Area Renewable Energy, Greenhouse Gas Topics GHG inventory, Low emission development planning, -LEDS, -NAMA Resource Type Lessons learned/best practices References Deutsche Gesellschaft für Internationale Zusammenarbeit (GIZ)[1] Program Overview The forthcoming climate regime will include a global mechanism called REDD - Reducing Emissions from Deforestation and Forest Degradation. Each developing country must draw up a Greenhouse Gas Inventory (GHG Inventory)

384

A Scenario-based Predictive Control Approach to Building HVAC Management Systems  

E-Print Network [OSTI]

A Scenario-based Predictive Control Approach to Building HVAC Management Systems Alessandra Parisio and Air Conditioning (HVAC) systems while minimizing the overall energy use. The strategy uses

Johansson, Karl Henrik

385

Building Scientific Workflows for Earth System Modelling with Windows Workflow Foundation  

E-Print Network [OSTI]

Building Scientific Workflows for Earth System Modelling with Windows Workflow Foundation Matthew J developed a framework for the composition, execution and management of integrated Earth system models

386

Y-12 Plant decontamination and decommissioning Technology Logic Diagram for Building 9201-4: Volume 3, Technology evaluation data sheets: Part B, Decontamination; robotics/automation; waste management  

SciTech Connect (OSTI)

This volume consists of the Technology Logic Diagrams (TLDs) for the decontamination, robotics/automation, and waste management areas.

NONE

1994-09-01T23:59:59.000Z

387

Top: Rudder Tower is one of 24 Texas A&M buildings undergoing energy efficiency upgrades.  

E-Print Network [OSTI]

Top: Rudder Tower is one of 24 Texas A&M buildings undergoing energy efficiency upgrades. Bottom control energy costs and provide a greener, more energy efficient campus for a more environmentally' building automation system (BAS) will improve energy efficiency and enable better HVAC control in buildings

388

Building a Global Federation System for Climate Change Research: The Earth System Grid Center for Enabling  

E-Print Network [OSTI]

Building a Global Federation System for Climate Change Research: The Earth System Grid Center for Enabling Technologies (ESG-CET) The Earth System Grid Center for Enabling Technologies Team: R Ananthakrishnan1 , D E Bernholdt7,9 , S Bharathi8 , D Brown5 , M Chen7 , A L Chervenak8 , L Cinquini5 , R Drach3

Chervenak, Ann

389

Energy efficiency in public buildings through ICT based control and monitoring systems  

E-Print Network [OSTI]

Energy efficiency in public buildings through ICT based control and monitoring systems G, France Keywords: energy efficiency, existing public buildings, control strategies, dynamic simulations a project entitled "Smart Energy Efficient Middleware for Public Spaces" (SEEMPubS). The project addresses

Paris-Sud XI, Université de

390

EPA ENERGY STAR Webcast: ENERGY STAR and Green Building Rating Systems  

Office of Energy Efficiency and Renewable Energy (EERE)

During this session, attendees will learn how to use EPA tools and resources to help meet requirements for green building rating systems such as the U.S. Green Building Council’s Leadership in...

391

List of Energy Mgmt. Systems/Building Controls Incentives | Open Energy  

Open Energy Info (EERE)

Mgmt. Systems/Building Controls Incentives Mgmt. Systems/Building Controls Incentives Jump to: navigation, search The following contains the list of 261 Energy Mgmt. Systems/Building Controls Incentives. CSV (rows 1 - 261) Incentive Incentive Type Place Applicable Sector Eligible Technologies Active AEP (Central and North) - CitySmart Program (Texas) Utility Rebate Program Texas Commercial Industrial Institutional Local Government Schools Boilers Central Air conditioners Chillers Comprehensive Measures/Whole Building Custom/Others pending approval Energy Mgmt. Systems/Building Controls Furnaces Heat pumps Lighting Lighting Controls/Sensors Motor VFDs Motors Roofs Windows Yes AEP (Central, North and SWEPCO) - Commercial Solutions Program (Texas) Utility Rebate Program Texas Commercial Industrial Institutional

392

In vivo robotics: the automation of neuroscience and other intact-system biological fields  

E-Print Network [OSTI]

Robotic and automation technologies have played a huge role in in vitro biological science, having proved critical for scientific endeavors such as genome sequencing and high-throughput screening. Robotic and automation ...

Forest, Craig R.

393

Lawrence Livermore to build advanced laser system in Czech Republic  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

9-06 9-06 For immediate release: 09/17/2013 | NR-13-09-06 High Resolution Image The High Repetition-Rate Advanced Petawatt Laser System, or HAPLS, will be designed, developed, assembled and tested at Lawrence Livermore. It will be transferred to the ELI Beamlines facility in 2016, where it will be commissioned for use by the international scientific community. Lawrence Livermore to build advanced laser system in Czech Republic Breanna Bishop, LLNL, (925) 423-9802, bishop33@llnl.gov High Resolution Image Artist renderings of the ELI Beamlines facility, currently under construction in the Czech Republic. High Resolution Image A CAD image of the ELI-HAPLS laser. LIVERMORE, Calif. - Lawrence Livermore National Laboratory (LLNL), through Lawrence Livermore National Security LLC (LLNS), has been awarded more than

394

Home Automation Using Elvin.  

E-Print Network [OSTI]

?? Home automation systems of today tend to be external solutions to an existing product that enable rather complex and expensive communications equipment to be… (more)

Malm, Anders

2005-01-01T23:59:59.000Z

395

Vehicle highway automation.  

E-Print Network [OSTI]

??Vehicle Highway Automation has been studied for several years but a practical system has not been possible because of technology limitations. New advances in sensing… (more)

Challa, Dinesh Kumar

2009-01-01T23:59:59.000Z

396

Automation systems for Demand Response, ForskEL (Smart Grid Project) | Open  

Open Energy Info (EERE)

systems for Demand Response, ForskEL (Smart Grid Project) systems for Demand Response, ForskEL (Smart Grid Project) Jump to: navigation, search Project Name Automation systems for Demand Response, ForskEL Country Denmark Coordinates 56.26392°, 9.501785° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":56.26392,"lon":9.501785,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

397

Dynamic Control of a Flow-Rack Automated Storage and Retrieval System  

E-Print Network [OSTI]

In this paper we propose a control scheme based on coloured Petri net (CPN) for a flow-rack automated storage and retrieval system. The AS/RS is modelled using Coloured Petri nets, the developed model has been used to capture and provide the rack state. We introduce in the control system an optimization module as a decision process which performs a real-time optimization working on a discrete events time scale. The objective is to find bin locations for the retrieval requests by minimizing the total number of retrieval cycles for a batch of requests and thereby increase the system throughput. By solving the optimization model, the proposed method gives according to customers request and the rack state, the best bin locations for retrieval, i.e. allowing at the same time to satisfy the customers request and carrying out the minimum of retrieval cycles.

Hachemi, Khalid

2009-01-01T23:59:59.000Z

398

Design and Development of a Robot-Based Automation System for Cryogenic Crystal Sample Mounting at the Advanced Photon Source  

SciTech Connect (OSTI)

X-ray crystallography is the primary method to determine the 3D structures of complex macromolecules at high resolution. In the years to come, the Advanced Photon Source (APS) and similar 3rd-generation synchrotron sources elsewhere will become the most powerful tools for studying atomic structures of biological molecules. One of the major bottlenecks in the x-ray data collection process is the constant need to change and realign the crystal sample. This is a very time- and manpower-consuming task. An automated sample mounting system will help to solve this bottleneck problem. We have developed a novel robot-based automation system for cryogenic crystal sample mounting at the APS. Design of the robot-based automation system, as well as its on-line test results at the Argonne Structural Biology Center (SBC) 19-BM experimental station, are presented in this paper.

Shu, D.; Preissner, C.; Nocher, D.; Han, Y.; Barraza, J.; Lee, P.; Lee, W.-K.; Cai, Z.; Ginell, S.; Alkire, R.; Lazarski, K.; Schuessler, R.; Joachimiak, A. [Argonne National Laboratory, 9700 S. Cass Av., Argonne, Il 60439 (United States)

2004-05-12T23:59:59.000Z

399

Automated structure solution with the PHENIX suite  

SciTech Connect (OSTI)

Significant time and effort are often required to solve and complete a macromolecular crystal structure. The development of automated computational methods for the analysis, solution, and completion of crystallographic structures has the potential to produce minimally biased models in a short time without the need for manual intervention. The PHENIX software suite is a highly automated system for macromolecular structure determination that can rapidly arrive at an initial partial model of a structure without significant human intervention, given moderate resolution, and good quality data. This achievement has been made possible by the development of new algorithms for structure determination, maximum-likelihood molecular replacement (PHASER), heavy-atom search (HySS), template- and pattern-based automated model-building (RESOLVE, TEXTAL), automated macromolecular refinement (phenix. refine), and iterative model-building, density modification and refinement that can operate at moderate resolution (RESOLVE, AutoBuild). These algorithms are based on a highly integrated and comprehensive set of crystallographic libraries that have been built and made available to the community. The algorithms are tightly linked and made easily accessible to users through the PHENIX Wizards and the PHENIX GUI.

Terwilliger, Thomas C [Los Alamos National Laboratory; Zwart, Peter H [LBNL; Afonine, Pavel V [LBNL; Grosse - Kunstleve, Ralf W [LBNL

2008-01-01T23:59:59.000Z

400

Automated Structure Solution with the PHENIX Suite  

SciTech Connect (OSTI)

Significant time and effort are often required to solve and complete a macromolecular crystal structure. The development of automated computational methods for the analysis, solution and completion of crystallographic structures has the potential to produce minimally biased models in a short time without the need for manual intervention. The PHENIX software suite is a highly automated system for macromolecular structure determination that can rapidly arrive at an initial partial model of a structure without significant human intervention, given moderate resolution and good quality data. This achievement has been made possible by the development of new algorithms for structure determination, maximum-likelihood molecular replacement (PHASER), heavy-atom search (HySS), template and pattern-based automated model-building (RESOLVE, TEXTAL), automated macromolecular refinement (phenix.refine), and iterative model-building, density modification and refinement that can operate at moderate resolution (RESOLVE, AutoBuild). These algorithms are based on a highly integrated and comprehensive set of crystallographic libraries that have been built and made available to the community. The algorithms are tightly linked and made easily accessible to users through the PHENIX Wizards and the PHENIX GUI.

Zwart, Peter H.; Zwart, Peter H.; Afonine, Pavel; Grosse-Kunstleve, Ralf W.; Hung, Li-Wei; Ioerger, Tom R.; McCoy, A.J.; McKee, Eric; Moriarty, Nigel; Read, Randy J.; Sacchettini, James C.; Sauter, Nicholas K.; Storoni, L.C.; Terwilliger, Tomas C.; Adams, Paul D.

2008-06-09T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

A System for Energy Saving in Commercial and Organizational Buildings  

Science Journals Connector (OSTI)

Energy consumption in commercial and organizational buildings with ... these buildings in order to achieve a sustainable energy saving. The method provides a direct control to ... behavior that is essential for e...

Hamid Abdi; Michael Fielding; James Mullins…

2013-01-01T23:59:59.000Z

402

Improving Building Energy System Performance by Continuous Commissioning  

E-Print Network [OSTI]

data. The first buildings to undergo a continuous commissioning process were in the Texas LoanSTAR program [Liu, et al, 1994, Claridge, et al, 1994]. These buildings had been retrofitted with various energy efficiency improvements, and measured hourly...

Turner, W. D.; Liu, M.; Claridge, D. E.; Haberl, J. S.

1996-01-01T23:59:59.000Z

403

Sustainability Assessment of Residential Building Energy System in Belgrade  

E-Print Network [OSTI]

of harmful substances. Multi-criteria method is a basic tool for the sustainability assessment in metropolitan cities. The design of potential options is the first step in the evaluation of buildings. The selection of a number of residential buildings...

Vucicevic, B.; Bakic, V.; Jovanovic, M.; Turanjanin, V.

2010-01-01T23:59:59.000Z

404

Software for fault detection in HVAC systems in commercial buildings  

E-Print Network [OSTI]

The building sector of the United States currently consumes over 41% of the United States primary energy supply. Estimates suggest that between 5 and 30% of any building's annual energy consumption is unknowingly wasted ...

Deshmukh, Suhrid Avinash

2014-01-01T23:59:59.000Z

405

Building America Case Study: Balancing Hydronic Systems in Multifamily...  

Energy Savers [EERE]

The buildings become under- and over- heated, which causes tenant discomfort and higher energy use intensity. In this project, the U.S. Department of Energy Building America team...

406

Automation of System Safety Analysis: Possibilities and Pitfalls Andrew Galloway, University of York, Heslington, York YO10 5DD UK  

E-Print Network [OSTI]

evolved to support safety analysis work (in this paper, we use the term "safety analysis" to encompass all, safety engineers may only achieve closure at the end of a system's working life, when it is possibleAutomation of System Safety Analysis: Possibilities and Pitfalls Andrew Galloway, University

Pumfrey, David

407

FORTRAN M AS A LANGUAGE FOR BUILDING EARTH SYSTEM MODELS \\Lambda  

E-Print Network [OSTI]

FORTRAN M AS A LANGUAGE FOR BUILDING EARTH SYSTEM MODELS \\Lambda Ian Foster Mathematics as a tool for building earth system models on massively parallel computers. I hypothesize that the use to investigate this hypothe­ sis. 2. Earth System Models An earth system model is a computer code designed

408

A Continuous Automated Vault Inventory System (CAVIS) for accountability monitoring of stored nuclear materials  

SciTech Connect (OSTI)

Nearly all facilities that store hazardous (radioactive or non-radioactive) materials must comply with prevailing federal, state, and local laws. These laws usually have components that require periodic physical inspections to insure that all materials remain safely and securely stored. The inspections are generally labor intensive, slow, put personnel at risk, and only find anomalies after they have occurred. The system described in this paper was developed for monitoring stored nuclear materials resulting from weapons dismantlement, but its applications extend to any storage facility that meets the above criteria. The traditional special nuclear material (SNM) accountability programs, that are currently used within most of the Department of Energy (DOE) complex, require the physical entry of highly trained personnel into SNM storage vaults. This imposes the need for additional security measures, which typically mandate that extra security personnel be present while SNM inventories are performed. These requirements increase labor costs and put additional personnel at risk to radiation exposure. In some cases, individuals have received radiation exposure equivalent to the annual maximum during just one inventory verification. With increasing overhead costs, the current system is rapidly becoming too expensive to operate, the need for an automated method of inventory verification is evident. The Continuous Automated Vault Inventory System (CAVIS) described in this paper was designed and prototyped as a low cost, highly reliable, and user friendly system that is capable of providing, real-time weight, gamma. and neutron energy confirmation from each item stored in a SNM vault. This paper describes the sensor technologies, the CAVIS prototype system (built at Y- 12 for highly enriched uranium storage), the technical requirements that must be achieved to assure successful implementation, and descriptions of sensor technologies needed for a plutonium facility.

Pickett, C.A.; Barham, M.A.; Gafford, T.A.; Hutchinson, D.P.; Jordan, J.K.; Maxey, L.C.; Moran, B.W.; Muhs, J.; Nodine, R.; Simpson, M.L. [and others

1994-12-08T23:59:59.000Z

409

Buildings to Grid Integration Technical Meeting: National Renewable Energy Laboratory, Energy Systems Integration Facility, Golden, CO  

Broader source: Energy.gov (indexed) [DOE]

Buildings to Grid Integration Buildings to Grid Integration Technical Meeting: National Renewable Energy Laboratory, Energy Systems Integration Facility Golden, CO December 2012 1 WELCOME Welcome to the Buildings to Grid Integration Technical Meeting and to Golden, Colorado. On behalf of the U.S. Department of Energy Building Technologies Program, I would like to thank you for attending and for your active participation. I look forward to meeting you and hearing your perspective on enabling significant buildings to grid integration. Everyone is here because we are working to make efficient transactions between buildings and the grid a commercial reality, whether it is through

410

CIMplementation™: Evaluating Manufacturing Automation  

E-Print Network [OSTI]

in the manufacturing organization if CIMplementation~* is to succeed. 1.0 INTRODUCTION There is much discussion today about Com puter Integrated Manufacturing (CIM). Automation tools like Computer Aided Design (CAD) systems, robots, automated material handling...~ Pressing the frontier of technology in one's own manufactur ing facility will not be without its pitfalls. Second, while automation engineers may be able to piece together the technological pieces of a CIM system, they cannot and do not evaluate...

Krakauer, J.

411

Residential Buildings  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Apartment building exterior and interior Apartment building exterior and interior Residential Buildings EETD's research in residential buildings addresses problems associated with whole-building integration involving modeling, measurement, design, and operation. Areas of research include the movement of air and associated penalties involving distribution of pollutants, energy and fresh air. Contacts Max Sherman MHSherman@lbl.gov (510) 486-4022 Iain Walker ISWalker@lbl.gov (510) 486-4692 Links Residential Building Systems Group Batteries and Fuel Cells Buildings Energy Efficiency Applications Commercial Buildings Cool Roofs and Heat Islands Demand Response Energy Efficiency Program and Market Trends High Technology and Industrial Systems Lighting Systems Residential Buildings Simulation Tools Sustainable Federal Operations

412

Energy Savings with Energy-Efficient HVAC Systems in Commercial Buildings of Hong Kong  

E-Print Network [OSTI]

of the electricity in Hong Kong is consumed by commercial buildings, and heating, ventilation and air-conditioning (HVAC) is the largest end-user in such buildings, improving the efficiency of HVAC systems in commercial buildings, is the key measure to take in Hong...

Yang, J.; Chan, K.; Wu, X.

2006-01-01T23:59:59.000Z

413

Impacts of Regional Electricity Prices and Building Type on the Economics of Commercial Photovoltaic Systems  

SciTech Connect (OSTI)

To identify the impacts of regional electricity prices and building type on the economics of solar photovoltaic (PV) systems, 207 rate structures across 77 locations and 16 commercial building types were evaluated. Results for expected solar value are reported for each location and building type. Aggregated results are also reported, showing general trends across various impact categories.

Ong, S.; Campbell, C.; Clark, N.

2012-12-01T23:59:59.000Z

414

Honeywell Modular Automation System Computer Software Documentation for the Magnesium Hydroxide Precipitation Process  

SciTech Connect (OSTI)

The purpose of this Computer Software Document (CSWD) is to provide configuration control of the Honeywell Modular Automation System (MAS) in use at the Plutonium Finishing Plant (PFP) for the Magnesium Hydroxide Precipitation Process in Rm 23OC/234-52. This CSWD describes hardware and PFP/FFS developed software for control of Magnesium Hydroxide Precipitation process located in room 230, 234-52. The Honeywell and Plant Scape software generate limited configuration reports for the developed control software. These reports are described in the following section and are attached as addendum's. This plan applies to PFP Engineering Manager, Thermal Stabilization Cognizant Engineers, Solutions Stabilization Engineers, and the Shift Technical Advisors responsible for the Honeywell MAS software/hardware and administration of the Honeywell System.

STUBBS, A.M.

2001-02-01T23:59:59.000Z

415

Synergy Between Building Rating Systems and Design Methodology for Intelligent and Green Buildings  

E-Print Network [OSTI]

. What is needed is a new integral design approach which enables to integrate the different aspects of green and intelligent buildings in a supportive framework during the design process. Especially the focus is on Multi Criteria Decision making within...

Zeiler, W.; Boxem, G.

416

Database Supported Bacnet Data Acquisition System for Building Energy Diagnostics  

E-Print Network [OSTI]

manufactured by AutomatedLogic Corporation is connected to a Windows 7 computer. In the control panel there are some pre-programmed BACnet object data points. Through command line query, it is already known that these points include ?Analog Fig14... manufactured by AutomatedLogic Corporation is connected to a Windows 7 computer. In the control panel there are some pre-programmed BACnet object data points. Through command line query, it is already known that these points include ?Analog Fig14...

Li, Z.; Augenbroe, G.

2011-01-01T23:59:59.000Z

417

Technical and Energy Assessment of Building Integrated Photovoltaic Systems applied to the UAE Office Buildings  

E-Print Network [OSTI]

-33586 Page 936. Available at: http://www.nrel.gov/docs/fy03osti/35645.pdf . ESL-IC-10-10-40 Proceedings of the Tenth International Conference for Enhanced Building Operations, Kuwait, October 26-28, 2010 ... of the Tenth International Conference for Enhanced Building Operations, Kuwait, October 26-28, 2010 References [1] Abu Dhabi Water & Electricity Company (ADWEC). 2009. See: http://www.adwec.ae/maps_graphs/ [2] Kumar K, Sharma SD, Jain L, 2007. Stand...

Radhi, H.

2010-01-01T23:59:59.000Z

418

Author manuscript, published in "Information and Software Technology (2011)" DOI: 10.1016/j.infsof.2011.09.006 API2MoL: Automating the building of bridges between APIs and Model- Driven Engineering  

E-Print Network [OSTI]

Context. A software artefact typically makes its functionality available through a specialized Application Programming Interface (API) describing the set of services offered to client applications. In fact, building any software system usually involves managing a plethora of APIs, which complicates the development process. In Model-Driven Engineering (MDE), where models are the key elements of any software engineering activity, this API management should take place at the model level. Therefore, tools that facilitate the integration of APIs and MDE are clearly needed. Objective. Our goal is to automate the implementation of API-MDE bridges for supporting both the creation of models from API objects and the generation of such API objects from models. In this sense, this paper presents the API2MoL approach, which provides a declarative rule-based language to easily write mapping definitions to link API specifications and the metamodel that represents them. These definitions are then executed to convert API objects into model elements or vice versa. The approach also allows both the metamodel and the mapping to be automatically obtained from the API specification (bootstrap process). Method. After implementing the API2MoL engine, its correctness was validated using several APIs.

Javier Luis; Cánovas Izquierdo; Frédéric Jouault; Jordi Cabot; Jesús García Molina

2011-01-01T23:59:59.000Z

419

Field demonstration of automated demand response for both winter and summer events in large buildings in the Pacific Northwest  

Science Journals Connector (OSTI)

There are growing strains on the electric grid as cooling peaks grow and equipment ages. Increased penetration of renewables on the grid is also straining electricity supply systems and the need for flexible dema...

Mary Ann Piette; Sila Kiliccote; Junqiao H. Dudley

2013-11-01T23:59:59.000Z

420

International Symposium on Daylighting Buildings (IEA SHC TASK 31) Integrating Automated Shading and Smart Glazings with Daylight  

E-Print Network [OSTI]

technologies on the market today. The challenge of controlling solar gain and managing daylight, view and glare systems and in the other we explore the use of electrochromic glazings. Each study involves both

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Automated design synthesis of robotic/human workcells for improved manufacturing system design in hazardous environments  

SciTech Connect (OSTI)

Manufacturing tasks that are deemed too hazardous for workers require the use of automation, robotics, and/or other remote handling tools. The associated hazards may be radiological or nonradiological, and based on the characteristics of the environment and processing, a design may necessitate robotic labor, human labor, or both. There are also other factors such as cost, ergonomics, maintenance, and efficiency that also effect task allocation and other design choices. Handling the tradeoffs of these factors can be complex, and lack of experience can be an issue when trying to determine if and what feasible automation/robotics options exist. To address this problem, we utilize common engineering design approaches adapted more for manufacturing system design in hazardous environments. We limit our scope to the conceptual and embodiment design stages, specifically a computational algorithm for concept generation and early design evaluation. In regard to concept generation, we first develop the functional model or function structure for the process, using the common 'verb-noun' format for describing function. A common language or functional basis for manufacturing was developed and utilized to formalize function descriptions and guide rules for function decomposition. Potential components for embodiment are also grouped in terms of this functional language and are stored in a database. The properties of each component are given as quantitative and qualitative criteria. Operators are also rated for task-relevant criteria which are used to address task compatibility. Through the gathering of process requirements/constraints, construction of the component database, and development of the manufacturing basis and rule set, design knowledge is stored and available for computer use. Thus, once the higher level process functions are defined, the computer can automate the synthesis of new design concepts through alternating steps of embodiment and function structure updates/decomposition. In the process, criteria guide function allocation of components/operators and help ensure compatibility and feasibility. Through multiple function assignment options and varied function structures, multiple design concepts are created. All of the generated designs are then evaluated based on a number of relevant evaluation criteria: cost, dose, ergonomics, hazards, efficiency, etc. These criteria are computed using physical properties/parameters of each system based on the qualities an engineer would use to make evaluations. Nuclear processes such as oxide conversion and electrorefining are utilized to aid algorithm development and provide test cases for the completed program. Through our approach, we capture design knowledge related to manufacturing and other operations in hazardous environments to enable a computational program to automatically generate and evaluate system design concepts.

Williams, Joshua M. [Los Alamos National Laboratory

2012-06-12T23:59:59.000Z

422

An Application of State-Of-The-Art HVAC and Building Systems  

E-Print Network [OSTI]

AN APPLICATION OF STATE-OF-THE-ART HVAC AND BUILDING SYSTEMS DONALD P. FIORINO, M.S., P.E. Energy Conservation Manager Texas Instruments, Inc. Defense Systems and Electronics Group Dallas, Texas ABSTRACT This case study describes... the successful application of state-of-the-art HVAC and building systems at a large commercial office and industrial facility. The facility's exterior envelope systems, HVAC systems, lighting systems, energy conservation systems, exhaust/heat recovery...

Fiorino, D. P.

423

The evolution of building integrated photovoltaics (BIPV) in the German and French technological innovation systems for solar cells.  

E-Print Network [OSTI]

??Building integrated photovoltaics (BIPV) are photovoltaic (PV) systems, fulfilling a function of a building and therefore allowing synergy effects by substituting the ordinary envelope of… (more)

Rode, Johannes

2007-01-01T23:59:59.000Z

424

Transmission and Grid Integration: Electricity, Resources, & Building Systems Integration (Fact Sheet)  

SciTech Connect (OSTI)

Factsheet developed to describe the activites of the Transmission and Grid Integration Group within NREL's Electricity, Resources, and Buildings Systems Integration center.

Not Available

2009-09-01T23:59:59.000Z

425

INVESTIGATION OF SYSTEM DYNAMICS APPLIED TO BUILDING SIMULATION FOR ANTI-TERRORISM RESOURCE ALLOCATION  

E-Print Network [OSTI]

INVESTIGATION OF SYSTEM DYNAMICS APPLIED TO BUILDING SIMULATION FOR ANTI-TERRORISM RESOURCE ............................................................................. 26 2.8 Terrorism-Resistant Design

Bank, Lawrence C.

426

Procedure for Measuring and Reporting the Performance of Photovoltaic Systems in Buildings  

SciTech Connect (OSTI)

This procedure provides a standard method for measuring and characterizing the long-term energy performance of photovoltaic (PV) systems in buildings and the resulting implications to the building's energy use. The performance metrics determined here may be compared against benchmarks for evaluating system performance and verifying that performance targets have been achieved. Uses may include comparison of performance with the design intent; comparison with other PV systems in buildings; economic analysis of PV systems in buildings; and the establishment of long-term performance records that enable maintenance staff to monitor trends in energy performance.

Pless, S.; Deru, M.; Torcellini, P.; Hayter, S.

2005-10-01T23:59:59.000Z

427

REDESIGN OF HVAC SYSTEM TO IMPROVE ENERGY EFFICIENCY OF EDUCATIONAL BUILDING.  

E-Print Network [OSTI]

??An energy modeling software was used to analyze the current building configuration and simulations were performed in an attempt to redesign the current HVAC system… (more)

Hagene, Brian Matthew

2012-01-01T23:59:59.000Z

428

Building Energy Information Systems: State of the Technology and User Case Studies  

E-Print Network [OSTI]

800,000) | Controls | Performance Monitoring Automated LogicAutomated Logic Corporation WebCTRL Corporation WebCTRLAutomated Energy Automated Logic Chevron EnergySolutions

Granderson, Jessica

2010-01-01T23:59:59.000Z

429

Plug and Play Distributed Power Systems for Smart-Grid Connected Building |  

Broader source: Energy.gov (indexed) [DOE]

Emerging Technologies » Plug and Play Distributed Power Systems Emerging Technologies » Plug and Play Distributed Power Systems for Smart-Grid Connected Building Plug and Play Distributed Power Systems for Smart-Grid Connected Building The U.S. Department of Energy (DOE) is currently conducting research into plug-and-play distributed power systems for smart- grid connected buildings. Project Description This project seeks to advance and demonstrate a plug-and-play building energy micro-grid concept for integrating energy storage, loads, and sources at the building level with the external utility grid. The micro-grid demonstration is expected to include the following: Diesel synchronous generator Energy storage device Otis regenerative elevator system representing building critical loads Smart interface with the utility grid

430

Co-design of control algorithm and embedded platform for building HVAC systems  

Science Journals Connector (OSTI)

The design of heating, ventilation and air conditioning (HVAC) systems is crucial for reducing energy consumption in buildings. As complex cyber-physical systems, HVAC systems involve three closely-related subsystems -- the control algorithm, the physical ... Keywords: building energy efficiency, co-design, platform-based design

Mehdi Maasoumy; Qi Zhu; Cheng Li; Forrest Meggers; Alberto Sangiovanni-Vincentelli

2013-04-01T23:59:59.000Z

431

Seismic Intensity Estimation of Tall Buildings in Earthquake Early Warning System  

E-Print Network [OSTI]

Seismic Intensity Estimation of Tall Buildings in Earthquake Early Warning System M. H. Cheng & T warning system is currently being tested through the California Integrated Seismic Network (CISN) (http: earthquake early warning system, tall buildings, seismic intensity 1. INTRODUCTION In California, United

Greer, Julia R.

432

Automated Stellar Spectral Classification and Parameterization for the Masses  

E-Print Network [OSTI]

Stellar spectroscopic classification has been successfully automated by a number of groups. Automated classification and parameterization work best when applied to a homogeneous data set, and thus these techniques primarily have been developed for and applied to large surveys. While most ongoing large spectroscopic surveys target extragalactic objects, many stellar spectra have been and will be obtained. We briefly summarize past work on automated classification and parameterization, with emphasis on the work done in our group. Accurate automated classification in the spectral type domain and parameterization in the temperature domain have been relatively easy. Automated parameterization in the metallicity domain, formally outside the MK system, has also been effective. Due to the subtle effects on the spectrum, automated classification in the luminosity domain has been somewhat more difficult, but still successful. In order to extend the use of automated techniques beyond a few surveys, we present our current efforts at building a web-based automated stellar spectroscopic classification and parameterization machine. Our proposed machinery would provide users with MK classifications as well as the astrophysical parameters of effective temperature, surface gravity, mean abundance, abundance anomalies, and microturbulence.

Ted von Hippel; Carlos Allende Prieto; Chris Sneden

2002-08-08T23:59:59.000Z

433

Quality Management System Guidelines - Building America Top Innovation...  

Energy Savers [EERE]

guid-quality-mgnt.png The whole-building approach of constructing high performance homes requires a high degree of coordination and interdependencies between designers,...

434

Environment/Health/Safety/Security (EHSS): Building Access  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Building Access Building Access Access Control - On-site access is controlled by either keys or by LBNL's automated access control system. LBNL's automated access control system is used for exterior perimeter doors to most buildings, as well as some individual labs, offices, and equipment. The access system is linked to the LBNL Human Resources PeopleSoft database and is updated with the employees' or affiliates' current appointment status at the Laboratory. . If your LBNL appointment end date has expired, then your access will be suspended. Security Access Managers (SAM) Administrators - LBNL's automated access control system is a decentralized access permission control structure managed by each Division or major program via Security Access Managers (SAM) Administrators and In-putters. Go here for the current

435

Building Technologies Office: Advancing Building Energy Codes  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Building Energy Codes Building Energy Codes Printable Version Share this resource Send a link to Building Technologies Office: Advancing Building Energy Codes to someone by E-mail Share Building Technologies Office: Advancing Building Energy Codes on Facebook Tweet about Building Technologies Office: Advancing Building Energy Codes on Twitter Bookmark Building Technologies Office: Advancing Building Energy Codes on Google Bookmark Building Technologies Office: Advancing Building Energy Codes on Delicious Rank Building Technologies Office: Advancing Building Energy Codes on Digg Find More places to share Building Technologies Office: Advancing Building Energy Codes on AddThis.com... Popular Links Success Stories Previous Next Lighten Energy Loads with System Design. Warming Up to Pump Heat.

436

Building America Technology Solutions for New and Existing Homes: Balancing Hydronic Systems in Multifamily Buildings, Chicago, Illinois (Fact Sheet)  

Broader source: Energy.gov [DOE]

In this case study , Partnership for Advanced Residential Retrofit and Elevate Energy. explores cost-effective distribution upgrades and balancing measures in multifamily hydronic systems, providing a resource to contractors, auditors, and building owners on best practices to improve tenant comfort and lower operating costs.

437

A BEMS-Assisted Commissioning Tool to Improve the Energy Performance of HVAC Systems  

E-Print Network [OSTI]

The evolving capabilities of Building Energy Management Systems (BEMS) offer new opportunities to automate some parts of the commissioning process and can generate benefits over the entire life of a building. These benefits include a reduction...

Choiniere, D.; Corsi, M.

2003-01-01T23:59:59.000Z

438

E-Print Network 3.0 - automated tracking system Sample Search...  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Computer Technologies and Information Sciences 10 http:hfs.sagepub.com Ergonomics Society Summary: of complacency and bias in human interaction with automated and...

439

Modular design and implementation of a low cost home automation system using web-services.  

E-Print Network [OSTI]

??The idea of home automation has existed and worked on by several researchers. The idea of controlling devices, around a home, in way to provide… (more)

Gomasa, Sunny Peter

2011-01-01T23:59:59.000Z

440

Design and Implementation of an Open, Interoperable Automated Demand Response Infrastructure  

E-Print Network [OSTI]

of Fully Automated Demand Response in Large Facilities. CEC-Fully Automated Demand Response Tests in Large Facilities.Management and Demand Response in Commercial Building. ,

Piette, Mary Ann; Kiliccote, Sila; Ghatikar, Girish

2008-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Systems and methods for controlling energy use in a building management system using energy budgets  

DOE Patents [OSTI]

Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A feedback controller is used to generate a manipulated variable based on an energy use setpoint and a measured energy use. The manipulated variable may be used for adjusting the operation of an HVAC device.

Wenzel, Michael J; Drees, Kirk H

2014-09-23T23:59:59.000Z

442

Automation on the laboratory bench  

Science Journals Connector (OSTI)

Automation on the laboratory bench ... In designing an automation kit the authors attempted to give chemistry a system which is versatile and easy to apply in taking over the boring and difficult task of controlling parameters manually. ...

M. Legrand; A. Foucard

1978-01-01T23:59:59.000Z

443

Advancing Net-Zero Energy Commercial Buildings; Electricity, Resources, & Building Systems Integration (Fact Sheet)  

SciTech Connect (OSTI)

This fact sheet provides an overview of the research the National Renewable Energy Laboratory is conducting to achieve net-zero energy buildings (NZEBs). It also includes key definitions of NZEBs and inforamtion about an NZEB database that captures information about projects around the world.

Not Available

2009-10-01T23:59:59.000Z

444

Recent Developments of the Modelica "Buildings" Library for Building Energy and Control Systems  

E-Print Network [OSTI]

consumption and related green house gas emis- sions. For example, in the United States, build- ings consume 2. Section 4 presents applications with models for multizone airflow simulation and for co-simulation in these packages augment models from the Modelica Standard Library and from the Modelica.Fluid library. Base

445

A mobile robot based system for fully automated thermal 3D mapping  

Science Journals Connector (OSTI)

Abstract It is hard to imagine living in a building without electricity and a heating or cooling system these days. Factories and data centers are equally dependent on a continuous functioning of these systems. As beneficial as this development is for our daily life, the consequences of a failure are critical. Malfunctioning power supplies or temperature regulation systems can cause the close-down of an entire factory or data center. Heat and air conditioning losses in buildings lead to a large waste of the limited energy resources and pollute the environment unnecessarily. To detect these flaws as quickly as possible and to prevent the negative consequences constant monitoring of power lines and heat sources is necessary. To this end, we propose a fully automatic system that creates 3D thermal models of indoor environments. The proposed system consists of a mobile platform that is equipped with a 3D laser scanner, an RGB camera and a thermal camera. A novel 3D exploration algorithm ensures efficient data collection that covers the entire scene. The data from all sensors collected at different positions is joined into one common reference frame using calibration and scan matching. In the post-processing step a model is built and points of interest are automatically detected. A viewer is presented that aids experts in analyzing the heat flow and localizing and identifying heat leaks. Results are shown that demonstrate the functionality of the system.

Dorit Borrmann; Andreas Nüchter; Marija Ðakulovi?; Ivan Maurovi?; Ivan Petrovi?; Dinko Osmankovi?; Jasmin Velagi?

2014-01-01T23:59:59.000Z

446

Combined heat and power systems for commercial buildings: investigating cost, emissions, and primary energy reduction based on system components.  

E-Print Network [OSTI]

?? Combined heat and power (CHP) systems produce electricity and useful heat from fuel. When power is produced near a building which consumes power, transmission… (more)

Smith, Amanda D.

2012-01-01T23:59:59.000Z

447

Systems and methods for controlling energy use in a building management system using energy budgets  

SciTech Connect (OSTI)

Systems and methods for limiting power consumption by a heating, ventilation, and air conditioning (HVAC) subsystem of a building are shown and described. A mathematical linear operator is found that transforms the unused or deferred cooling power usage of the HVAC system based on pre-determined temperature settings to a target cooling power usage. The mathematical operator is applied to the temperature settings to create a temperature setpoint trajectory expected to provide the target cooling power usage.

Wenzel, Michael J.

2012-06-17T23:59:59.000Z

448

Automated Demand Response Technologies and Demonstration in New York City  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Technologies and Demonstration in New York City Technologies and Demonstration in New York City using OpenADR Title Automated Demand Response Technologies and Demonstration in New York City using OpenADR Publication Type Report LBNL Report Number LBNL-6470E Year of Publication 2013 Authors Kim, Joyce Jihyun, Sila Kiliccote, and Rongxin Yin Date Published 09/2013 Publisher LBNL/NYSERDA Abstract Demand response (DR) - allowing customers to respond to reliability requests and market prices by changing electricity use from their normal consumption pattern - continues to be seen as an attractive means of demand-side management and a fundamental smart-grid improvement that links supply and demand. Since October 2011, the Demand Response Research Center at Lawrence Berkeley National Laboratory and New York State Energy Research and Development Authority have conducted a demonstration project enabling Automated Demand Response (Auto-DR) in large commercial buildings located in New York City using Open Automated Demand Response (OpenADR) communication protocols. In particular, this project focuses on demonstrating how OpenADR can automate and simplify interactions between buildings and various stakeholders in New York State including the independent system operator, utilities, retail energy providers, and curtailment service providers. In this paper, we present methods to automate control strategies via building management systems to provide event-driven demand response, price response and demand management based on OpenADR signals. We also present cost control opportunities under day-ahead hourly pricing for large customers and Auto-DR control strategies developed for demonstration buildings. Lastly, we discuss the communication architecture and Auto-DR system designed for the demonstration project to automate price response and DR participation.

449

EduCase : an automated lecture video recording, post-processing, and viewing system that utilizes multimodal inputs to provide a dynamic student experience  

E-Print Network [OSTI]

This thesis describes the design, implementation, and evaluation of EduCase: an inexpensive automated lecture video recording, post-processing, and viewing system. The EduCase recording system consists of three devices, ...

Itani, Sara T

2013-01-01T23:59:59.000Z

450

Department of Mechanical and Nuclear Engineering Fall 2010 Wind Tunnel Automated Bicycle Adjustment System  

E-Print Network [OSTI]

PENN STATE Department of Mechanical and Nuclear Engineering Fall 2010 Wind Tunnel Automated Bicycle with the development of Aerofit's prototype portable wind tunnel used in the aerodynamic testing of bicycles was to automate this adjustment of the bicycle seat and aerobars in order to decrease the time for fitting each

Demirel, Melik C.

451

An automated hydride generation-cryogenic trapping-ICP-MS system for measuring inorganic and methylated Ge, Sb and As species  

E-Print Network [OSTI]

An automated hydride generation-cryogenic trapping-ICP-MS system for measuring inorganic of both flow injection and batch hydride generation and couples it to an automated cryogenic trapping unit with detection by ICP-MS. The Teflon cryogenic trap was packed with 10 cm of SE-30 5% Chromosorb W-HP 80­100 mesh

Canberra, University of

452

Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)  

SciTech Connect (OSTI)

The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.

Wang, Na; Gorrissen, Willy J.

2013-01-11T23:59:59.000Z

453

EA-1087: Proposed Induction Linac System Experiments in Building 51B at  

Broader source: Energy.gov (indexed) [DOE]

7: Proposed Induction Linac System Experiments in Building 7: Proposed Induction Linac System Experiments in Building 51B at Lawrence Berkeley National Laboratory, Berkeley, California EA-1087: Proposed Induction Linac System Experiments in Building 51B at Lawrence Berkeley National Laboratory, Berkeley, California SUMMARY This EA evaluates the environmental impacts of a proposal to modify existing Building 51B at the U.S. Department of Energy's Lawrence Berkeley National Laboratory to install and conduct experiments on a new Induction Linear Accelerator System. PUBLIC COMMENT OPPORTUNITIES None available at this time. DOCUMENTS AVAILABLE FOR DOWNLOAD September 8, 1995 EA-1087: Finding of No Significant Impact Proposed Induction Linac System Experiments in Building 51B at Lawrence Berkeley National Laboratory, Berkeley, California

454

Grid-Competitive Residential and Commercial Fully Automated PV Systems Technology: Final technical Report, August 2011  

SciTech Connect (OSTI)

Under DOE's Technology Pathway Partnership program, SunPower Corporation developed turn-key, high-efficiency residential and commercial systems that are cost effective. Key program objectives include a reduction in LCOE values to 9-12 cents/kWh and 13-18 cents/kWh respectively for the commercial and residential markets. Target LCOE values for the commercial ground, commercial roof, and residential markets are 10, 11, and 13 cents/kWh. For this effort, SunPower collaborated with a variety of suppliers and partners to complete the tasks below. Subcontractors included: Solaicx, SiGen, Ribbon Technology, Dow Corning, Xantrex, Tigo Energy, and Solar Bridge. SunPower's TPP addressed nearly the complete PV value chain: from ingot growth through system deployment. Throughout the award period of performance, SunPower has made progress toward achieving these reduced costs through the development of 20%+ efficient modules, increased cell efficiency through the understanding of loss mechanisms and improved manufacturing technologies, novel module development, automated design tools and techniques, and reduced system development and installation time. Based on an LCOE assessment using NREL's Solar Advisor Model, SunPower achieved the 2010 target range, as well as progress toward 2015 targets.

Brown, Katie E.; Cousins, Peter; Culligan, Matt; Jonathan Botkin; DeGraaff, David; Bunea, Gabriella; Rose, Douglas; Bourne, Ben; Koehler, Oliver

2011-08-26T23:59:59.000Z

455

Progress and challenges in the automated construction of Markov state models for full protein systems  

Science Journals Connector (OSTI)

Markov state models (MSMs) are a powerful tool for modeling both the thermodynamics and kinetics of molecular systems. In addition they provide a rigorous means to combine information from multiple sources into a single model and to direct future simulations/experiments to minimize uncertainties in the model. However constructing MSMs is challenging because doing so requires decomposing the extremely high dimensional and rugged free energy landscape of a molecular system into long-lived states also called metastable states. Thus their application has generally required significant chemical intuition and hand-tuning. To address this limitation we have developed a toolkit for automating the construction of MSMs called MSMBUILDER (available at https://simtk.org/home/msmbuilder). In this work we demonstrate the application of MSMBUILDER to the villin headpiece (HP-35 NleNle) one of the smallest and fastest folding proteins. We show that the resulting MSM captures both the thermodynamics and kinetics of the original molecular dynamics of the system. As a first step toward experimental validation of our methodology we show that our model provides accurate structure prediction and that the longest timescale events correspond to folding.

Gregory R. Bowman; Kyle A. Beauchamp; George Boxer; Vijay S. Pande

2009-01-01T23:59:59.000Z

456

Current Building Energy Codes: Using the Process to Advance Energy Efficient Systems  

Broader source: Energy.gov (indexed) [DOE]

12 12 NREL / Build America Stakeholders Meeting Presented by David Karmol, VP, Federal & External Affairs  The purpose of this presentation is to provide information on ICC model codes that impact the design and construction of buildings, and tactics to allow Building America advances to be incorporated into the model code and/or recognized by building code officials  The expected outcome is an ability to expand the reach of Build America innovations, by using available resources to mainstream new energy efficiency systems into building practices nationwide 2 3  Will apply to traditional commercial and high-performance buildings.  Consistent and coordinated with the ICC family of Codes & Standards.  Applicable to the construction of

457

Potential of Evaporative Cooling Systems for Buildings in India  

E-Print Network [OSTI]

Evaporative cooling potential for building in various climatic zones in India is investigated. Maintainable indoor conditions are obtained from the load - capacity analysis for the prevailing ambient conditions. For the assumed activity level...

Maiya, M. P.; Vijay, S.

2010-01-01T23:59:59.000Z

458

A Casebase of Intelligent Buildings for E-learning Systems  

E-Print Network [OSTI]

. The knowledge base aims to support currently used e-learning tools such as Blackboard, and to make a knowledge engine to facilitate other relevant research into intelligent buildings. A pilot knowledge base is introduced to demonstrate the usability...

Chen, Z.; Clements-Croome, D. J.; Ozkan, G.; Hong, J.; Xu, Z.

2006-01-01T23:59:59.000Z

459

Integrated Energy Systems (IES) for Buildings: A Market Assessment...  

Open Energy Info (EERE)

15 November, 2012 - 13:05 Literature Review The author analyzed the market of combine heat and power in commercial buildings. The paper provided the market size of CHP. It...

460

Disciplined agility for process control & automation ; Disciplined agility for process control and automation .  

E-Print Network [OSTI]

??Process automation vendors must consider agility as a basis to gain a competitive edge in innovation. Process Automation systems can impact the operating cost of… (more)

Tibazarwa, Augustine

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Investigation of Latent-Heat Storage Systems for Green Building Applications  

Science Journals Connector (OSTI)

In green building applications, highest energy demands are needed for air conditioning to ... heat storage systems during the usage of solar energy and ground-sourced heat pump systems for ... period, analyses sh...

Devrim Aydin; Zafer Utlu; Olcay Kincay

2014-01-01T23:59:59.000Z

462

IZ-CON: an intelligent zone controller for building systems operation  

E-Print Network [OSTI]

into a number of well-formed sub-domains. Toward this end, a generative scheme for representation of buildings' systems control architecture is developed that allows for a structured distribution of systems' control logic. The scheme is cogently derived...

Mahdavi, A.; Schub, M.

2012-01-01T23:59:59.000Z

463

Smart Buildings and Demand Response  

Science Journals Connector (OSTI)

Advances in communications and control technology the strengthening of the Internet and the growing appreciation of the urgency to reduce demand side energy use are motivating the development of improvements in both energy efficiency and demand response (DR) systems in buildings. This paper provides a framework linking continuous energy management and continuous communications for automated demand response (Auto?DR) in various times scales. We provide a set of concepts for monitoring and controls linked to standards and procedures such as Open Automation Demand Response Communication Standards (OpenADR). Basic building energy science and control issues in this approach begin with key building components systems end?uses and whole building energy performance metrics. The paper presents a framework about when energy is used levels of services by energy using systems granularity of control and speed of telemetry. DR when defined as a discrete event requires a different set of building service levels than daily operations. We provide examples of lessons from DR case studies and links to energy efficiency.

2011-01-01T23:59:59.000Z

464

Development of an Automated Microfluidic System for DNA Collection, Amplification, and Detection of Pathogens  

SciTech Connect (OSTI)

This project was focused on developing and testing automated routines for a microfluidic Pathogen Detection System. The basic pathogen detection routine has three primary components; cell concentration, DNA amplification, and detection. In cell concentration, magnetic beads are held in a flow cell by an electromagnet. Sample liquid is passed through the flow cell and bacterial cells attach to the beads. These beads are then released into a small volume of fluid and delivered to the peltier device for cell lysis and DNA amplification. The cells are lysed during initial heating in the peltier device, and the released DNA is amplified using polymerase chain reaction (PCR) or strand displacement amplification (SDA). Once amplified, the DNA is then delivered to a laser induced fluorescence detection unit in which the sample is detected. These three components create a flexible platform that can be used for pathogen detection in liquid and sediment samples. Future developments of the system will include on-line DNA detection during DNA amplification and improved capture and release methods for the magnetic beads during cell concentration.

Hagan, Bethany S.; Bruckner-Lea, Cynthia J.

2002-12-01T23:59:59.000Z

465

Automated Sealing of Home Enclosures with Aerosol Particles  

Broader source: Energy.gov (indexed) [DOE]

October 14, 2011 October 14, 2011 Automated Sealing of Home Enclosures with Aerosol Particles Welcome to the Webinar! We will start at 11:00 AM Eastern Time Be sure that you are also dialed into the telephone conference call: Dial-in number: 888-989-7679; Pass code: 3599368 Download the presentation at: www.buildingamerica.gov/meetings.html Building Technologies Program eere.energy.gov Building America: Introduction October 14, 2011 Chuck Booten Chuck.booten@nrel.gov Building Technologies Program Building Technologies Program eere.energy.gov * Reduce energy use in new and existing residential buildings * Promote building science and systems engineering / integration approach * "Do no harm": Ensure safety, health and durability are maintained or improved

466

Building Thermal Envelope Systems and Materials (BTESM) and research utilization/technology transfer progress report for DOE (Department of Energy) Office of Buildings Energy Research  

SciTech Connect (OSTI)

The Monthly Report of the Building Thermal Envelope Systems and Materials (BTESM) Program is a monthly update of both in-house ORNL projects and subcontract activities in the research areas of building materials, wall systems, foundations, roofs, building diagnostics, and research utilization and technology transfer. Presentations are not stand-alone paragraphs every month. Their principal values are the short-time lapse between accomplishment and reporting and their evolution over a period of several months.

Burn, G. (comp.)

1990-08-01T23:59:59.000Z

467

Publications : Daylighting The New York Times Building  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

Publications Publications Overview The architectural approach The owner's approach Daylighting field study Daylighting control systems Automated roller shades Procurement specifications Shades and Shade Controls Lighting Controls Visualizing daylight Commissioning/ verification Demand response Mainstream solutions Post-occupancy evaluation Publications Sponsors Project team Publications Technical Publications Post-occupancy Evaluation A post-occupancy monitored evaluation of the dimmable lighting, automated shading, and underfloor air distribution system in The New York Times Building. Eleanor S. Lee, Luis L. Fernandes, Brian Coffey, Andrew McNeil, Robert Clear, Tom Webster, Fred Bauman, Darryl Dickerhoff, David Heinzerling, Tyler Hoyt. LBNL Technical report, January 2013. LBNL-6023E.

468

On the development of a universal automated fixturing system through encapsulation techniques  

E-Print Network [OSTI]

Universal automated fixturing can transform a machine tool into a rapid prototyping machine with many advantages over current rapid prototyping methods. Using this modified machine tool, prototype parts can be manufactured ...

Lee, Elmer C., 1973-

2001-01-01T23:59:59.000Z

469

Automation Status  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

NREL Manufacturing R&D Workshop NREL Manufacturing R&D Workshop NREL H2/FC Manufacturing R&D Workshop Automation Status Garry Sperrick garry@sperkllc.com 585-259-0311 August 11, 2011 Automation Status NREL Manufacturing R&D Workshop Presentation Overview ƒ Brief Introduction ƒ DOE / NREL - Review & Discussion ƒ Automation Platforms ƒ Automation Processes ƒ Automation Considerations of the Manufacturer ƒ Manufacturer and the Supplier ƒ Three (3) Automation Programs Following these Guidelines ƒ Automotive Component Manufacturing ƒ Medical Manufacturing ƒ Membrane Electrode Assembly Manufacturing ƒ Hypothetical Fuel Cell Manufacturing Platforms August 11, 2011 Automation Status NREL Manufacturing R&D Workshop Professional Bio ƒ Automation Technician - Mobil Chemical

470

The Community Surface Dynamics Modeling System: Experiences on Building a Collaborative Modeling Platform  

E-Print Network [OSTI]

The Community Surface Dynamics Modeling System: Experiences on Building a Collaborative Modeling VOLUNTEERISM MANY DEVELOPERS Grand Challenge: Building a Toolbox of Component Models with guidance and input Members and Governance · Tools for Collaboration 1) CSDMS Wiki 2) CSDMS Modeling Tool · Strategies

Wright, Dawn Jeannine

471

Building Robot Systems to Interact With People in Real Environments Bruce A. Maxwell  

E-Print Network [OSTI]

Building Robot Systems to Interact With People in Real Environments Bruce A. Maxwell Swarthmore College Swarthmore, PA 19081 maxwell@swarthmore.edu September 23, 2006 1 Introduction Building robots to interact with real people in real environments poses many challenges to both the robots

Maxwell, Bruce

472

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture  

E-Print Network [OSTI]

Seamless Handover in Buildings Using HVAC Ducts: A New System Architecture Ariton E. Xhafa, Paisarn-- In this paper, we present an innovative solution to the handover problem in multi-story buildings using HVAC of the indoor wireless networks that use the heating, ventilation, and air conditioning (HVAC) ducts

Stancil, Daniel D.

473

Continuous Commissioning® of a Single Fan Dual Duct System in an Office Building  

E-Print Network [OSTI]

Continuous Commissioning ® of a Single Fan Dual Duct System in an Office Building D. Dong M. Liu, Ph.D., P.E Jinrong Wang, P.E Energy Systems Laboratory Energy Systems Laboratory... of AHU control sequences can significantly improve building comfort and reduce HVAC energy cost. REFERENCES 1. Liu, M., Y. Zhu, and D. E. Claridge, “Use of EMCS Recorded Data to Identify Potential Savings Due to Improved HVAC Operations...

Dong, D.; Liu, M.

2005-01-01T23:59:59.000Z

474

Shielded cells transfer automation  

SciTech Connect (OSTI)

Nuclear waste from shielded cells is removed, packaged, and transferred manually in many nuclear facilities. Radiation exposure is absorbed by operators during these operations and limited only through procedural controls. Technological advances in automation using robotics have allowed a production waste removal operation to be automated to reduce radiation exposure. The robotic system bags waste containers out of glove box and transfers them to a shielded container. Operators control the system outside the system work area via television cameras. 9 figures.

Fisher, J J

1984-01-01T23:59:59.000Z

475

Context-based automated defect classification system using multiple morphological masks  

DOE Patents [OSTI]

Automatic detection of defects during the fabrication of semiconductor wafers is largely automated, but the classification of those defects is still performed manually by technicians. This invention includes novel digital image analysis techniques that generate unique feature vector descriptions of semiconductor defects as well as classifiers that use these descriptions to automatically categorize the defects into one of a set of pre-defined classes. Feature extraction techniques based on multiple-focus images, multiple-defect mask images, and segmented semiconductor wafer images are used to create unique feature-based descriptions of the semiconductor defects. These feature-based defect descriptions are subsequently classified by a defect classifier into categories that depend on defect characteristics and defect contextual information, that is, the semiconductor process layer(s) with which the defect comes in contact. At the heart of the system is a knowledge database that stores and distributes historical semiconductor wafer and defect data to guide the feature extraction and classification processes. In summary, this invention takes as its input a set of images containing semiconductor defect information, and generates as its output a classification for the defect that describes not only the defect itself, but also the location of that defect with respect to the semiconductor process layers.

Gleason, Shaun S. (Knoxville, TN); Hunt, Martin A. (Knoxville, TN); Sari-Sarraf, Hamed (Lubbock, TX)

2002-01-01T23:59:59.000Z

476

Buildings Energy Data Book: 5.5 Thermal Distribution Systems  

Buildings Energy Data Book [EERE]

by Building Activity Education 0.5 1.3 Food Sales 1.1 6.4 Food Service 1.5 6.4 Health Care 1.5 5.6 Lodging 0.5 1.9 Mercantile and Service 0.9 2.7 Office 1.3 3.3 Public...

477

DOE, RTI to Design and Build Gas Cleanup System for IGCC Power Plants |  

Broader source: Energy.gov (indexed) [DOE]

DOE, RTI to Design and Build Gas Cleanup System for IGCC Power DOE, RTI to Design and Build Gas Cleanup System for IGCC Power Plants DOE, RTI to Design and Build Gas Cleanup System for IGCC Power Plants July 13, 2009 - 1:00pm Addthis Washington, DC - The U.S. Department of Energy (DOE) announces a collaborative project with Research Triangle Institute (RTI) International to design, build, and test a warm gas cleanup system to remove multiple contaminants from coal-derived syngas. The 50-MWe system will include technologies to remove trace elements such as mercury and arsenic, capture the greenhouse gas carbon dioxide (CO2), and extract more than 99.9 percent of the sulfur from the syngas. A novel process to convert the extracted sulfur to a pure elemental sulfur product will also be tested. This project supports DOE's vision of coal power plants with near-zero

478

DOE, RTI to Design and Build Gas Cleanup System for IGCC Power Plants |  

Broader source: Energy.gov (indexed) [DOE]

DOE, RTI to Design and Build Gas Cleanup System for IGCC Power DOE, RTI to Design and Build Gas Cleanup System for IGCC Power Plants DOE, RTI to Design and Build Gas Cleanup System for IGCC Power Plants July 13, 2009 - 1:00pm Addthis Washington, DC - The U.S. Department of Energy (DOE) announces a collaborative project with Research Triangle Institute (RTI) International to design, build, and test a warm gas cleanup system to remove multiple contaminants from coal-derived syngas. The 50-MWe system will include technologies to remove trace elements such as mercury and arsenic, capture the greenhouse gas carbon dioxide (CO2), and extract more than 99.9 percent of the sulfur from the syngas. A novel process to convert the extracted sulfur to a pure elemental sulfur product will also be tested. This project supports DOE's vision of coal power plants with near-zero

479

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2  

E-Print Network [OSTI]

A LIBRARY OF HVAC COMPONENT MODELS FOR USE IN AUTOMATED1 DIAGNOSTICS2 3 4 Peng Xu, Philip Haves HVAC system (air handling units and air distribution systems). The models are used to predict of automatic documentation methods in the library. INTRODUCTION The increasing complexity of building HVAC

480

Automatic control systems for gas-turbine units in mini power stations: Testing automation at the stages of design and tuning  

Science Journals Connector (OSTI)

This paper presents the testing automation procedure for automatic control systems of gas-turbine units used as drives in small-size power stations. We substantiate the applicability of mathematical modeling...

B. V. Kavalerov

2013-11-01T23:59:59.000Z

Note: This page contains sample records for the topic "building automation system" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

Hybrid Control Network Intrusion Detection Systems for Automated Power Distribution Systems  

E-Print Network [OSTI]

and improve the reliability of the distribution system [3].distribution topology for protection and to improve reliability.

Parvania, Masood; Koutsandria, Georgia; Muthukumar, Vishak; Peisert, Sean; McParland, Chuck; Scaglione, Anna

2014-01-01T23:59:59.000Z

482

Co-Simulation of Building Energy and Control Systems with the Building Controls Virtual Test Bed  

E-Print Network [OSTI]

Proceedings of the 2nd Modelica conference, pages 55–1 – 55–Germany, March 2002. Modelica Association and Deutschesand Sven Erik Matts- son. Modelica for embedded systems. In

Wetter, Michael

2012-01-01T23:59:59.000Z

483

Dynamic building enclosures : the design of an innovative constructive system which permits mechanically-driven, computer-controlled shape transformations to the building envelope  

E-Print Network [OSTI]

Dynamic Building Enclosures is a system of prefabricated, lightweight, kit-of-parts wall and/or roof elements. This system has the unique capability of dynamically altering, or mutating its shape in reaction to changing ...

Nelson, Eric (Eric Freeman), 1964-

1998-01-01T23:59:59.000Z

484

Real-Time Optimization Strategies for Building Systems  

Science Journals Connector (OSTI)

This hinders market penetration and slows down smart grid initiatives such as demand response. ... In addition, it is necessary to determine the impact of different electricity market incentives and programs such as day-ahead bidding, real-time pricing, and demand response on the cost improvements of MPC over existing control architectures. ... A conclusion from this study is that buildings do not benefit from following economic objectives if no revenue is provided (e.g., negative prices or demand response payments). ...

Victor M. Zavala

2012-08-27T23:59:59.000Z

485

Integrated Energy Systems (IES) for Buildings: A Market Assessment(LeMar  

Open Energy Info (EERE)

Integrated Energy Systems (IES) for Buildings: A Market Assessment(LeMar Integrated Energy Systems (IES) for Buildings: A Market Assessment(LeMar 2002) Home > Groups > Energy Systems Integration Qinsun's picture Submitted by Qinsun(35) Member 15 November, 2012 - 13:05 Literature Review The author analyzed the market of combine heat and power in commercial buildings. The paper provided the market size of CHP. It analyzed the reduction of emission, energy and cost by 2020. It discussed barrier, market power and impact. It is a good market analysis proach. However, it only considered existing CHP techniques in Commercial buildings. Groups: Energy Systems Integration Login to post comments Latest documents Qinsun Research topics related to ESI Posted: 15 Nov 2012 - 13:55 by Qinsun Qinsun Prospects for Nuclear Power(Davis 2012) Posted: 15 Nov 2012 - 13:36 by Qinsun

486

Technical Meeting: Data/Communication Standards and Interoperability of Building Appliances, Equipment, and Systems  

Broader source: Energy.gov [DOE]

On May 1, BTO hosted a technical meeting on Data and Communications Standards and Interoperability of Building Appliances, Equipment and Systems. This page includes the presentation slides and meeting notes.

487

Building America Expert Meeting: Summary for Diagnostic and Performance Feedback for Residential Space Conditioning System Equipment  

Broader source: Energy.gov [DOE]

The Building Science Consortium held an Expert Meeting on Diagnostic and Performance Feedback for Residential Space Conditioning System Equipment on April 26,l 2010 on the NIST campus in Gaithersburg, Maryland.

488

Solar Energy to Drive Absorption Cooling Systems Suitable for Small Building Applications  

E-Print Network [OSTI]

results and an overview of the performance of low capacity single stage and half-effect absorption cooling systems, suitable for residential and small building applications. The primary heat source is solar energy supplied from flat plate collectors...

Gomri, R.

2010-01-01T23:59:59.000Z

489

Development of Energy Consumption Database Management System of Existing Large Public Buildings  

E-Print Network [OSTI]

The statistic data of energy consumption are the base of analyzing energy consumption. The scientific management method of energy consumption data and the development of database management system plays an important role in building energy...

Li, Y.; Zhang, J.; Sun, D.

2006-01-01T23:59:59.000Z

490

Impact of the Variable Refrigerant Volume Air Conditioning System on Building Energy Efficiency  

E-Print Network [OSTI]

The application of the variable refrigerant volume multi-zone air conditioning systems has met with mixed results since the publication of the Design Standard for Energy Efficiency of Public Buildings. This paper analyzes the characteristics...

Zhu, H.

2006-01-01T23:59:59.000Z

491

Building Urban Resilience and Sustainability (BURST): Integrating Adaptive Infrastructure Systems with Institutional and Ecological Functions  

E-Print Network [OSTI]

Building Urban Resilience and Sustainability (BURST): Integrating Adaptive Infrastructure Systems Professor, School of Architecture Ernesto Indacochea, Professor, Civil & Materials Engineering Kazuya with the sustainability paradigm. It is organized around the principle that resilient and sustainable infrastructures

Illinois at Chicago, University of

492

Model-Based Methodology for Building Confidence in a Dynamic Measuring System  

E-Print Network [OSTI]

experimentation and computational simulation methods will be used to build trust in this measurement system. This process of establishing credibility will be presented in the form of a proposed methodology. This proposed methodology will utilize verification...

Reese, Isaac Mark

2013-05-03T23:59:59.000Z

493

Computational Study on Thermal Properties of HVAC System with Building Structure Thermal Storage  

E-Print Network [OSTI]

Building structure thermal storage (BSTS) HVAC systems can store heat during nighttime thermal storage operation (nighttime operation hours) by using off-peak electricity and release it in the daytime air-conditioning operation (daytime operation...

Sato, Y.; Sagara, N.; Ryu, Y.; Maehara, K.; Nagai, T.

2007-01-01T23:59:59.000Z

494

Building the DOE Systems Biology Knowledgebase (KBase) ( 7th Annual SFAF Meeting, 2012)  

ScienceCinema (OSTI)

Tom Brettin on "Building the DOE Systems Biology Knowledgebase (KBase)" at the 2012 Sequencing, Finishing, Analysis in the Future Meeting held June 5-7, 2012 in Santa Fe, New Mexico.

Brettin, Tom [Oak Ridge National Laboratory

2013-03-22T23:59:59.000Z

495

Building America Technology Solutions for New and Existing Homes:Hydronic Systems Designing for Setback Operations  

Broader source: Energy.gov [DOE]

This guide, developed by Consortium for Advanced Residential Buildings, provides step-by-step instructions for heating contractors and hydronic designers for selecting the proper control settings to maximize system performance and improve response time when using a thermostat setback.

496

Integrating Solar Thermal and Photovoltaic Systems in Whole Building Energy Simulation  

E-Print Network [OSTI]

INTEGRATING SOLAR THERMAL AND PHOTOVOLTAIC SYSTEMS IN WHOLE BUILDING ENERGY SIMULATION Soolyeon Cho1 and Jeff S. Haberl2 1The Catholic University of America, Washington, DC 2Texas A&M University, College Station, TX ABSTRACT... This paper introduces methodologies on how the renewable energy generated by the solar thermal and solar photovoltaic (PV) systems installed on site can be integrated in the whole building simulation analyses, which then can be available to analyze...

Cho, S.; Haberl, J.

497

A building’s refurbishment knowledge and device based decision support system  

Science Journals Connector (OSTI)

The integration of knowledge-based, devices-based and decision support systems have a very promising future in scientific research. The authors of this paper participated in the project Framework 6, ‘Bringing Retrofit Innovation to the Application ...

Edmundas Zavadskas; Arturas Kaklauskas; Povilas Vainiunas; Ruta Dubakiene; Andrius Gulbinas; Mindaugas Krutinis; Petras Cyras; Liudas Rimkus

2006-09-01T23:59:59.000Z

498

Test Automation Ant JUnit Test Automation  

E-Print Network [OSTI]

Test Automation Ant JUnit Test Automation Mohammad Mousavi Eindhoven University of Technology, The Netherlands Software Testing 2012 Mousavi: Test Automation #12;Test Automation Ant JUnit Outline Test Automation Ant JUnit Mousavi: Test Automation #12;Test Automation Ant JUnit Why? Challenges of Manual Testing

Mousavi, Mohammad

499

The performance of UVGI Systems and its Limitation in Building Applications  

Broader source: All U.S. Department of Energy (DOE) Office Webpages (Extended Search)

The performance of UVGI Systems and its Limitation in Building Applications The performance of UVGI Systems and its Limitation in Building Applications Speaker(s): Minki Sung Date: August 20, 2010 - 12:00pm Location: 90-3122 Seminar Host/Point of Contact: William Fisk One of the main concerns for healthcare building design is how to prevent the dispersion of airborne infectious diseases such as tuberculosis. Moreover, it is suspected that fungi and bacteria growing in air handling units (AHUs) can also cause respiratory diseases in building occupants. Ultraviolet germicidal irradiation (UVGI) systems have been known to have an apparent germicidal effect on infectious microbes and have been considered as a possible countermeasure. In this presentation, some results achieved from a series of laboratory and field experiments and numerical

500

Building America Top Innovations Hall of Fame Profile … Basement Insulation Systems  

Broader source: Energy.gov (indexed) [DOE]

Efficient Efficient and durable construction practices are critical for basements because basements can account for 10% to 30% of a home's total heat loss and provide significant risk of moisture problems due to extensive cold surfaces at the walls and slab. BUILDING AMERICA TOP INNOVATIONS HALL OF FAME PROFILE INNOVATIONS CATEGORY: 1. Advanced Technologies and Practices 1.1 Building Science Solutions Basement Insulation Systems Building America research has provided essential guidance for one of the most challenging construction assemblies in cold-climate high-performance homes. Basements can easily develop mold, rot, and odor problems if not designed properly. Building America researchers have investigated basement insulation systems that keep the space dry, healthy, and odor-free. These systems effectively address the