Powered by Deep Web Technologies
Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

"1. Bruce Mansfield","Coal","FirstEnergy Generation Corp",2510  

U.S. Energy Information Administration (EIA) Indexed Site

Pennsylvania" Pennsylvania" "1. Bruce Mansfield","Coal","FirstEnergy Generation Corp",2510 "2. PPL Susquehanna","Nuclear","PPL Susquehanna LLC",2450 "3. Limerick","Nuclear","Exelon Nuclear",2264 "4. Peach Bottom","Nuclear","Exelon Nuclear",2244 "5. Homer City Station","Coal","Midwest Generations EME LLC",1884 "6. Beaver Valley","Nuclear","FirstEnergy Nuclear Operating Company",1777 "7. Conemaugh","Coal","RRI Energy NE Management Co",1712 "8. Keystone","Coal","RRI Energy NE Management Co",1711 "9. PPL Martins Creek","Gas","PPL Martins Creek LLC",1702

2

Coal-fired power materials  

Science Conference Proceedings (OSTI)

Advances in materials technologies over the last decade that is allowing coal-fired power plants to be built with higher efficiencies than the current generation are described. 2 figs., 2 tabs.

Viswanathan, V.; Purgert, R.; Rawls, P. [Electric Power Research Institute, Palo Alto, CA (United States)

2008-08-15T23:59:59.000Z

3

Tracking New Coal-Fired Power Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

New Coal-Fired Power Plants New Coal-Fired Power Plants (data update 1/13/2012) January 13, 2012 National Energy Technology Laboratory Office of Strategic Energy Analysis & Planning Erik Shuster 2 Tracking New Coal-Fired Power Plants This report is intended to provide an overview of proposed new coal-fired power plants that are under development. This report may not represent all possible plants under consideration but is intended to illustrate the potential that exists for installation of new coal-fired power plants. Additional perspective has been added for non-coal-fired generation additions in the U.S. and coal-fired power plant activity in China. Experience has shown that public announcements of power plant developments do not provide an accurate representation of eventually

4

Carbon Dioxide Capture from Coal-Fired  

E-Print Network (OSTI)

Carbon Dioxide Capture from Coal-Fired Power Plants: A Real Options Analysis May 2005 MIT LFEE 2005. LFEE 2005-002 Report #12;#12;i ABSTRACT Investments in three coal-fired power generation technologies environment. The technologies evaluated are pulverized coal (PC), integrated coal gasification combined cycle

5

Coal-Fired Power Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

Impacts of TMDLs on Impacts of TMDLs on Coal-Fired Power Plants April 2010 DOE/NETL-2010/1408 Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference therein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The

6

NETL: Coal-Fired Power Plants (CFPPs)  

NLE Websites -- All DOE Office Websites (Extended Search)

Coal Sources Coal-Fired Power Plants (CFPPs) Where is the coal in the United States? Coal Across the U.S. The U.S. contains coal resources in various places. The coal occurs...

7

Existing Coal-fired Power Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

Water Vulnerabilities for Existing Coal-fired Power Plants August 2010 DOENETL-20101429 Disclaimer This report was prepared as an account of work sponsored by an agency of the...

8

Coal-fired diesel generator  

SciTech Connect

The objective of the proposed project is to test the technical, environmental, and economic viability of a coal-fired diesel generator for producing electric power in small power generating markets. Coal for the diesel generator would be provided from existing supplies transported for use in the University`s power plant. A cleanup system would be installed for limiting gaseous and particulate emissions. Electricity and steam produced by the diesel generator would be used to supply the needs of the University. The proposed diesel generator and supporting facilities would occupy approximately 2 acres of land adjacent to existing coal- and oil-fired power plant and research laboratory buildings at the University of Alaska, Fairbanks. The environmental analysis identified that the most notable changes to result from the proposed project would occur in the following areas: power plant configuration at the University of Alaska, Fairbanks; air emissions, water use and discharge, and the quantity of solid waste for disposal; noise levels at the power plant site; and transportation of coal to the power plant. No substantive adverse impacts or environmental concerns were identified in analyzing the effects of these changes.

1997-05-01T23:59:59.000Z

9

Mansfield Fellowship | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mansfield Fellowship Mansfield Fellowship Mansfield Fellowship Program Overview: The two-year Mansfield Fellowship Program enables U.S. federal government employees to develop an in-depth understanding of Japan, learn how its government works, and establish relationships with their counterparts n the government of Japan as well as in the business, professional, and academic communities. The Fellows spend a year working full-time in Japanese government offices, preceded by a year of full-time rigorous language and area studies training in the United States. After the year in Japan, the Fellows are required to serve at least two additional years in the federal government where it is anticipated they will continue to work on projects involving Japan-related issues. Once they return to the United States, Fellows are expected to continue

10

Steam Plant Replaces Outdated Coal-Fired System | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Steam Plant Replaces Outdated Coal-Fired System Steam Plant Replaces Outdated Coal-Fired System September 1, 2012 - 12:00pm Addthis A new natural gas-fired steam plant will replace...

11

Decommissioning Handbook for Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

This handbook lays out the steps necessary to fully decommission a coal-fired power plant. The handbook includes ways to handle permitting, environmental cleanup, site dismantlement, and site remediation, and discusses overall decommissioning costs. It is based on three actual case studies of coal plants recently decommissioned: the Arkwright coal-fired plant of Georgia Power, the Watts Bar coal-fired plant of TVA, and the Port Washington coal-fired plant of Wisconsin Electric Power.

2004-11-04T23:59:59.000Z

12

Aerosol nucleation in coal-fired power-plant plumes  

Science Conference Proceedings (OSTI)

New-particle nucleation within coal-fired power-plant plumes can have large effects on particle number concentrations

2013-01-01T23:59:59.000Z

13

Coal-fired generation staging a comeback. 2nd ed.  

Science Conference Proceedings (OSTI)

The report is an overview of the renewed U.S. market interest in coal-fired power generation. It provides a concise look at what is driving interest in coal-fired generation, the challenges faced in implementing coal-fired generation projects, and the current and future state of coal-fired generation. Topics covered in the report include: An overview of coal-fired generation including its history, the current market environment, and its future prospects; An analysis of the key business factors that are driving renewed interest in coal-fired generation; An analysis of the challenges that are hindering the implementation of coal-fired generation projects; A description of coal-fired generation technologies; A review of the economic drivers of coal-fired generation project success; An evaluation of coal-fired generation versus other generation technologies; A discussion of the key government initiatives supporting new coal-fired generation; and A listing of planned coal-fired generation projects. 13 figs., 12 tabs., 1 app.

NONE

2007-07-01T23:59:59.000Z

14

Mansfield Municipal Electric Department - Residential Energy Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Mansfield Municipal Electric Department - Residential Energy Mansfield Municipal Electric Department - Residential Energy Efficiency Rebate Program Mansfield Municipal Electric Department - Residential Energy Efficiency Rebate Program < Back Eligibility Residential Savings Category Heating & Cooling Commercial Heating & Cooling Cooling Appliances & Electronics Maximum Rebate $100 limit per customer account for appliances purchased in the same calendar year. Program Info Expiration Date 12/31/2014 State Massachusetts Program Type Utility Rebate Program Rebate Amount Central AC: $100 Refrigerators: $100 Clothes Washing Machines: $100 Dishwashers: $75 Dehumidifiers: $50 Window Air Conditioners: $50 Provider Mansfield Municipal Electric Department Mansfield Municipal Electric Department encourages energy efficiency

15

NETL: Coal-Fired Power Plants (CFPPs)  

NLE Websites -- All DOE Office Websites (Extended Search)

NOx Sources NOx Sources Coal-Fired Power Plants (CFPPs) Causes of greenhouse gases, Including NOx What is NOx? Environmental Impacts NOx Sources Reduction Efforts Several greenhouse gases, including NOx, are increasing due to human activities in the following areas: Burning of fossil fuel (for example, coal-fired power plants), Logging (mainly contributes to carbon monoxide), Agriculture processes, Use of chlorofluorocarbons (CFC) in holon fire suppression and refrigeration The chart below shows the three major gases contributing to greenhouse gas emissions along with their source by sector. Annual Greenhouse Gas Emissions by Sector Note: This figure was created and copyrighted by Robert A. Rohde from published data and is part of the Global Warming Art project. This image is an original work created for Global Warming Art Permission is granted to copy, distribute and/or modify this image under either:

16

Executive roundtable on coal-fired generation  

Science Conference Proceedings (OSTI)

Power Engineering magazine invited six industry executives from the coal-fired sector to discuss issues affecting current and future prospects of coal-fired generation. The executives are Tim Curran, head of Alstom Power for the USA and Senior Vice President and General Manager of Boilers North America; Ray Kowalik, President and General Manager of Burns and McDonnell Energy Group; Jeff Holmstead, head of Environmental Strategies for the Bracewell Giuliani law firm; Jim Mackey, Vice President, Fluor Power Group's Solid Fuel business line; Tom Shelby, President Kiewit Power Inc., and David Wilks, President of Energy Supply for Excel Energy Group. Steve Blankinship, the magazine's Associate Editor, was the moderator. 6 photos.

NONE

2009-09-15T23:59:59.000Z

17

Mansfield Municipal Electric Department - Residential Energy...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

50 Mansfield Municipal Electric Department encourages energy efficiency through the ENERGY STAR Appliance Rebate Incentive Program. Cash rebates are offered for ENERGY STAR...

18

NREL: Energy Analysis - Coal-Fired Electricity Generation Results...  

NLE Websites -- All DOE Office Websites (Extended Search)

Coal-Fired Electricity Generation Results - Life Cycle Assessment Harmonization Over the last 30 years, researchers have conducted hundreds of life cycle assessments of...

19

Projected retirements of coal-fired power plants - Today in ...  

U.S. Energy Information Administration (EIA)

Current trends in the electric power market put many coal-fired generators in the United States at risk for retirement. In the Annual Energy Outlook ...

20

Coal-fired electric generators continue to dominate electric ...  

U.S. Energy Information Administration (EIA)

More than 60% of electricity in the central region of the United States comes from coal-fired electric generators, down from 80% in the early part of ...

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Optical Gas Sensors for Advanced Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

Presentation Title, Optical Gas Sensors for Advanced Coal-Fired Power Plants. Author(s), Paul Ohodnicki, Congjun Wang, Douglas Kauffman, Kristi Kauffman,...

22

Enhanced Elemental Mercury Removal from Coal-fired Flue Gas by Sulfur-chlorine Compounds  

E-Print Network (OSTI)

removal from flue gas of coal-fired power plants. Environ.Speciation in a 100-MW Coal-Fired Boiler with Low-NOxControl Technologies for Coal-Fired Power Plants, DOE/NETL

Miller, Nai-Qiang Yan-Zan Qu Yao Chi Shao-Hua Qiao Ray Dod Shih-Ger Chang Charles

2008-01-01T23:59:59.000Z

23

Enhanced Elemental Mercury Removal from Coal-fired Flue Gas by Sulfur-chlorine Compounds  

E-Print Network (OSTI)

from flue gas of coal-fired power plants. Environ. Sci. &Technologies for Coal-Fired Power Plants, DOE/NETL Mercurynumber of coal-fired generating plants (1-3). The mercury is

Miller, Nai-Qiang Yan-Zan Qu Yao Chi Shao-Hua Qiao Ray Dod Shih-Ger Chang Charles

2008-01-01T23:59:59.000Z

24

EA-1183: Coal-fired Diesel Generator University of Alaska, Fairbanks...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

83: Coal-fired Diesel Generator University of Alaska, Fairbanks, Alaska EA-1183: Coal-fired Diesel Generator University of Alaska, Fairbanks, Alaska SUMMARY This EA evaluates the...

25

Retrofitted coal-fired firetube boiler and method employed therewith  

DOE Patents (OSTI)

A coal-fired firetube boiler and a method for converting a gas-fired firetube boiler to a coal-fired firetube boiler are disclosed. The converted boiler includes a plurality of combustion zones within the firetube and controlled stoichiometry within the combustion zones. 19 figs.

Wagoner, C.L.; Foote, J.P.

1995-07-04T23:59:59.000Z

26

Third International Conference on Improved Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

This international conference reviewed advances in materials, components, and designs for coal-fired power plants. Also showcased were results from the EPRI improved power plant project, similar collaborative European projects, and new power plants in Japan. The proceedings' 54 papers contribute to an improved international understanding of advanced coal-fired power plant technology.

1992-09-01T23:59:59.000Z

27

Retrofitted coal-fired firetube boiler and method employed therewith  

SciTech Connect

A coal-fired firetube boiler and a method for converting a gas-fired firetube boiler to a coal-fired firetube boiler, the converted boiler including a plurality of combustion zones within the firetube and controlled stoichiometry within the combustion zones.

Wagoner, Charles L. (Tullahoma, TN); Foote, John P. (Tullahoma, TN)

1995-01-01T23:59:59.000Z

28

Mercury Removal Characteristics of Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

The standard Ontario Hydro Method (OHM) was used into the flue gas mercury sampling before and after fabric filter (FF)/ electrostatic precipitator (ESP) locations in coal-fired power stations in China, and then various mercury speciation, Hg0, Hg2+ ... Keywords: coal-fired power plant, mercury, fabric filter, electrostatic precipitator

Yang Liguo, Fan Xiaoxu, Duanyu Feng, Wang Yunjun

2013-01-01T23:59:59.000Z

29

Coal Direct Chemical Looping Retrofit for Pulverized Coal-Fired...  

NLE Websites -- All DOE Office Websites (Extended Search)

Coal Direct Chemical Looping Retrofit for Pulverized Coal-Fired Power Plants with In-Situ CO 2 Capture Background Pulverized coal (PC)-fired power plants provide nearly 50% of...

30

Trace metal particulates in coal-fired power plant emissions.  

E-Print Network (OSTI)

??Since coal-fired power plants produce approximately 50% of U.S. energy, the toxic and environmental damaging effects of this energy source are important. Trace metals are (more)

Marett, Lanette Simone

2007-01-01T23:59:59.000Z

31

NETL: News Release - Making Tomorrow's Coal-Fired Power Plants...  

NLE Websites -- All DOE Office Websites (Extended Search)

May 4, 2001 Making Tomorrow's Coal-Fired Power Plants Cleaner and More Efficient August 21, 2001 DOE Selects 5 New Research Projects to Improve Combustors, Reduce Pollutants, and...

32

A Review of Hazardous Chemical Species Associated with CO2 Capture from Coal-Fired Power Plants and Their Potential Fate in CO2 Geologic Storage  

E-Print Network (OSTI)

Coal-fired Plants .capture technologies to coal-fired plants is also likely togroups. Conventional Coal-fired Plants Sulfur During

Apps, J.A.

2006-01-01T23:59:59.000Z

33

Edward Bruce Held  

Energy.gov (U.S. Department of Energy (DOE))

Edward Bruce Held is the Acting Administrator and Acting Undersecretary for Nuclear Security and the former Director of the Office of Intelligence and Counterintelligence.

34

The Magnetohydrodynamics Coal-Fired Flow Facility  

DOE Green Energy (OSTI)

Progress continued at MHD coal-fired flow facility. UTSI reports on progress in developing the technology for the steam bottoming portion of the MHD Steam Combined Cycle Power Plant. No Proof-of-Concept (POC) testing was conducted during the quarter but data analyses are reported from the test conducted during the prior quarter. Major results include corrosion data from the first 500 hours of testing on candidate tube materials in the superheater test module (SHTM). Solids mass balance data, electrostatic precipitator (ESP) and baghouse (BH) performance data, diagnostic systems and environmental data results from previous POC tests are included. The major activities this quarter were in facility modifications required to complete the scheduled POC test program. Activities reported include the installation of an automatic ash/seed removal system on the SHTM, the BH, and ESP hoppers. Also, a higher pressure compressor (350 psi) is being installed to provide additional blowing pressure to remove solids deposits on the convective heat transfer tubes in the high temperature zone where the deposits are molten. These activities are scheduled to be completed and ready for the next test, which is scheduled for late May 1990. Also, experiments on drying western coal are reported. The recommended system for modifying the CFFF coal system to permit processing of western coal is described. Finally, a new effort to test portions of the TRW combustor during tests in the CFFF is described. The status of system analyses being conducted under subcontract by the Westinghouse Electric Corporation is also described. 2 refs., 18 figs., 3 tabs.

Not Available

1990-11-01T23:59:59.000Z

35

Nitrogen oxide emissions from coal fired MHD plants  

DOE Green Energy (OSTI)

In this topical report, the nitrogen oxide emission issues from a coal fired MHD steam combined cycle power plant are summarized, both from an experimental and theoretical/calculational viewpoint. The concept of staging the coal combustion to minimize NO{sub x} is described. The impact of NO{sub x} control design choices on electrical conductivity and overall plant efficiency are described. The results of the NO{sub x} measurements in over 3,000 hours of coal fired testing are summarized. A chemical kinetics model that was used to model the nooks decomposition is described. Finally, optimum design choices for a low nooks plant are discussed and it is shown that the MHD Steam Coal Fired Combined Cycle Power Plant can be designed to operate with nooks emissions less than 0.05 lbm/MMBTU.

Chapman, J.N. [ed.

1996-03-01T23:59:59.000Z

36

Advanced Development Of The Coal Fired Oxyfuel Process With CO2...  

Open Energy Info (EERE)

Coal Fired Oxyfuel Process With CO2 Separation ADECOS Jump to: navigation, search Name Advanced Development Of The Coal-Fired Oxyfuel Process With CO2 Separation (ADECOS) Place...

37

Prestigious Coal-Fired Project of the Year Award Goes to Plant...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Prestigious Coal-Fired Project of the Year Award Goes to Plant Demonstrating Innovative DOE-Funded Technology Prestigious Coal-Fired Project of the Year Award Goes to Plant...

38

Quantification of Variability and Uncertainty in Hourly NOx Emissions from Coal-Fired Power Plants  

E-Print Network (OSTI)

1 Quantification of Variability and Uncertainty in Hourly NOx Emissions from Coal-Fired Power to quantify variability and uncertainty for NOx emissions from coal-fired power plants. Data for hourly NOx Uncertainty, Variability, Emission Factors, Coal-Fired Power Plants, NOx emissions, Regression Models

Frey, H. Christopher

39

Carbon Dioxide Capture from Coal-Fired Power Plants: A Real Options Analysis Ram Chandra Sekar  

E-Print Network (OSTI)

Carbon Dioxide Capture from Coal-Fired Power Plants: A Real Options Analysis by Ram Chandra Sekar;2 #12;3 Carbon Dioxide Capture in Coal-Fired Power Plants: A Real Options Analysis by Ram Chandra Sekar and Master of Science in Mechanical Engineering ABSTRACT Investments in three coal-fired power generation

40

Circular Economy Assessment for Coal-fired Power Plants Based on Supper-Efficiency DEA Model  

Science Conference Proceedings (OSTI)

Coal-fired power plants are the main pollution source in most areas of China. The implementation of circular economy in coal-fired power plants is necessary for environmental protection and also an effective way of energy saving and emission reduction. ... Keywords: circular economy assessment, circular economy improvement, coal-fired power plant, super-efficiency data envelopment analysis

Shao-lun Zeng; Hong Hu; Wei Wang

2009-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

MIT Energy Initiative Symposium | March 23, 2009 1 Retrofitting of Coal-Fired  

E-Print Network (OSTI)

MIT Energy Initiative Symposium | March 23, 2009 1 Retrofitting of Coal-Fired Power Plants for CO2 of Coal-Fired Power Plants for CO2 Emissions Mitigation The MIT Energy Initiative (MITEI) sponsored a symposium on the retrofitting of coal-fired power plants to capture CO2 emissions. This report summarizes

Williams, Brian C.

42

Gas Cofiring Assessment for Coal Fired Utility Boilers  

Science Conference Proceedings (OSTI)

This study evaluates gas co-firing as one option for coal-fired utility boilers. It provides electric power generators an objective review of the potential, experience to date, and economics of five gas co-firing technologies, plus a sixth pilot-scale application.

2000-08-23T23:59:59.000Z

43

Advanced Development Of The Coal Fired Oxyfuel Process With CO2 Separation  

Open Energy Info (EERE)

Coal Fired Oxyfuel Process With CO2 Separation Coal Fired Oxyfuel Process With CO2 Separation ADECOS Jump to: navigation, search Name Advanced Development Of The Coal-Fired Oxyfuel Process With CO2 Separation (ADECOS) Place Germany Product Dresden based initiative that has been formed to assess oxyfuel CCS technology. References Advanced Development Of The Coal-Fired Oxyfuel Process With CO2 Separation (ADECOS)[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Advanced Development Of The Coal-Fired Oxyfuel Process With CO2 Separation (ADECOS) is a company located in Germany . References ↑ "Advanced Development Of The Coal-Fired Oxyfuel Process With CO2 Separation (ADECOS)" Retrieved from "http://en.openei.org/w/index.php?title=Advanced_Development_Of_The_Coal_Fired_Oxyfuel_Process_With_CO2_Separation_ADECOS&oldid=341776

44

Applications of coatings in coal-fired energy systems  

SciTech Connect

Corrosion and erosion of metallic structural materials at elevated temperatures in complex multicomponent gas environments that include particulates are potential problems in many fossil energy systems, especially those using coal as a feedstock. The use of appropriate corrosion-resistant coatings on metallic components offers an avenue to minimize material degradation and extend component life. The purpose of this paper is to review the current status of coating performance in environments typical of pulverized-coal-fired boilers, coal gasification, fluidized-bed combustion, and gas turbines. The paper discusses the complexity of environments in different systems and the coating requirements for acceptable performance. Examples illustrate the morphology and corrosion/erosion performance of coating/structural alloy combinations exposed in some of these systems. La addition, future research and development needs are discussed for coating applications in several coal-fired systems.

Natesan, K.

1992-03-01T23:59:59.000Z

45

Thermal energy storage for coal-fired power generation  

DOE Green Energy (OSTI)

This paper presents an engineering and economic evaluation of using thermal energy storage (TES) with coal-fired conventional and combined cycle power plants. In the first case, conventional pulverized coal combustion equipment was assumed to continuously operate to heat molten nitrate salt which was then stored in a tank. During intermediate-load demand periods, hot salt was withdrawn from storage and used to generate steam for a Rankine steam power cycle. This allowed the coal-fired salt heater to be approximately one-third the size of a coal-fired boiler in a conventional cycling plant. The use of nitrate salt TES also reduced the levelized cost of power by between 5% and 24% depends on the operating schedule. The second case evaluate the use of thermal energy storage with an integrated gasification combined cycle (IGCC) power plant. In this concept, the nitrate salt was heated by a combination of the gas turbine exhaust and the hot fuel gas. The IGCC plant also contained a low-temperature storage unit that uses a mixture of oil and rock as the thermal storage medium. Thermal energy stored in the low-temperature TES was used to preheat the feedwater after it leaves the condenser and to produce process steam for other applications in the IGCC plant. This concept study also predicted a 5% to 20% reduction in levelized cost of power compared to other coal-fired alternatives. If significant escalation rates in the price of fuel were assumed, the concept could be competitive with natural-gas-fired intermediate-load power generation. A sensitivity analysis of using a direct-contact heat exchanger instead of the conventional finned-tube design showed a significant reduction in the installed capital cost. 3 refs., 2 figs., 6 tabs.

Drost, M.K.; Somasundaram, S.; Brown, D.R.; Antoniak, Z.I.

1990-11-01T23:59:59.000Z

46

Application of Multivariable Control to Oil and Coal Fired Boilers  

E-Print Network (OSTI)

Increased visibility provided by advanced measurement and control techniques has shown that control of oil and coal fired boilers is a complex problem involving simultaneous determination of flue gas carbon monoxide, hydrocarbon, opacity and temperature levels. A microcomputer-based control system which recognizes the inter-relationship of these variables has produced fuel savings averaging about 3% on coal and oil fired boilers. The system is described and case study data is presented for both coal and oil fired boilers.

Swanson, K.

1981-01-01T23:59:59.000Z

47

Current Status of Mercury Measurement at Coal-Fired Sources  

Science Conference Proceedings (OSTI)

The past five years have seen the emergence of federal regulation of mercury (Hg) emissions from coal-fired utility plants. This report provides a synopsis of the state of the science for measuring vapor phase Hg emissions at these plants. It provides a description of the systems currently in use, including information on their vendors and a discussion of lessons learned from recent demonstration projects.

2009-11-02T23:59:59.000Z

48

Exxon Chemical's Coal-Fired Combined Cycle Power Technology  

E-Print Network (OSTI)

Exxon Chemical's Central Engineering Division has recently developed and patented CAT-PAC for Industrial Cogeneration and Utility Power Plants. It involves the marriage of a conventional direct pulverized coal-fired boiler radiant section with a convection section adapted from our furnace experience. In particular, it is an open-cycle, hot air turbine arrangement with indirect heating of the air in the boiler convection section. The turbine exhaust is then used as pre-heated combustion air for the boiler. The air coil heats the 150 psig air from the standard gas turbine axial compressor to approximately, 1750F. Today, CAT-PAC would require about 10% less fuel (or 1000 Btu/kwh) than the best coal-fired Utility Plant for the same net power output, at a comparable investment. With improved air heater metallurgy, and/or trim firing of a premium fuel (up to 2000 F permissible gas turbine temperature), CAT-PAC savings would double to 20%. Today, in an industrial coal-fired cogeneration plant, CAT-PAC can produce up to 75% more power for a given steam load, while maintaining the highest cogeneration efficiencies. With improved metallurgy, and/or trim firing, the additional power would approach 100%.

Guide, J. J.

1985-05-01T23:59:59.000Z

49

Dark spreads measure returns over fuel costs of coal-fired ...  

U.S. Energy Information Administration (EIA)

The dark spread is a common metric used to estimate returns over fuel costs of coal-fired electric generators. A dark spread is the difference between ...

50

Coal-fired open cycle magnetohydrodynamic power plant emissions and energy efficiences  

E-Print Network (OSTI)

This study is a review of projected emissions and energy efficiencies of coal-fired open cycle MHD power plants. Ideally one

Gruhl, Jim

51

Thermal Integration of CO2 Compression Processes with Coal-Fired...  

NLE Websites -- All DOE Office Websites (Extended Search)

Thermal Integration of CO 2 Compression Processes with Coal-Fired Power Plants Equipped with Carbon Capture Background Increased attention is being placed on research into...

52

Most coal-fired electric capacity was built before 1980 - Today in ...  

U.S. Energy Information Administration (EIA)

Sales, revenue and prices, power plants, fuel use, stocks, generation, ... Some older coal-fired generators were retrofitted with various environmental controls ...

53

A baseline assessment of local mercury deposition from coal-fired power plants in Central Texas.  

E-Print Network (OSTI)

??Coal-fired power plants represent the largest source of anthropogenic mercury in the world. The Central Texas region as represented by the Heart of Texas Council (more)

Furl, Chad Van.

2006-01-01T23:59:59.000Z

54

Mercury concentrations in wetlands associated with coal-fired power plants in Illinois.  

E-Print Network (OSTI)

??Burning of fossil fuels by coal-fired power plants (CFPPs) is one of the largest sources of environmental mercury in the United States and there have (more)

Weir, Scott

2009-01-01T23:59:59.000Z

55

Coal-fired high performance power generating system. Final report  

SciTech Connect

As a result of the investigations carried out during Phase 1 of the Engineering Development of Coal-Fired High-Performance Power Generation Systems (Combustion 2000), the UTRC-led Combustion 2000 Team is recommending the development of an advanced high performance power generation system (HIPPS) whose high efficiency and minimal pollutant emissions will enable the US to use its abundant coal resources to satisfy current and future demand for electric power. The high efficiency of the power plant, which is the key to minimizing the environmental impact of coal, can only be achieved using a modern gas turbine system. Minimization of emissions can be achieved by combustor design, and advanced air pollution control devices. The commercial plant design described herein is a combined cycle using either a frame-type gas turbine or an intercooled aeroderivative with clean air as the working fluid. The air is heated by a coal-fired high temperature advanced furnace (HITAF). The best performance from the cycle is achieved by using a modern aeroderivative gas turbine, such as the intercooled FT4000. A simplified schematic is shown. In the UTRC HIPPS, the conversion efficiency for the heavy frame gas turbine version will be 47.4% (HHV) compared to the approximately 35% that is achieved in conventional coal-fired plants. This cycle is based on a gas turbine operating at turbine inlet temperatures approaching 2,500 F. Using an aeroderivative type gas turbine, efficiencies of over 49% could be realized in advanced cycle configuration (Humid Air Turbine, or HAT). Performance of these power plants is given in a table.

1995-08-31T23:59:59.000Z

56

Slag processing system for direct coal-fired gas turbines  

SciTech Connect

Direct coal-fired gas turbine systems and methods for their operation are provided by this invention. The systems include a primary combustion compartment coupled to an impact separator for removing molten slag from hot combustion gases. Quenching means are provided for solidifying the molten slag removed by the impact separator, and processing means are provided forming a slurry from the solidified slag for facilitating removal of the solidified slag from the system. The released hot combustion gases, substantially free of molten slag, are then ducted to a lean combustion compartment and then to an expander section of a gas turbine.

Pillsbury, Paul W. (Winter Springs, FL)

1990-01-01T23:59:59.000Z

57

Corrosion protection pays off for coal-fired power plants  

Science Conference Proceedings (OSTI)

Zinc has long been used to hot-dip galvanise steel to deliver protection in harsh environments. Powder River Basin or eastern coal-fired plants benefit from using galvanized steel for conveyors, vibratory feeders, coal hoppers, chutes, etc. because maintenance costs are essentially eliminated. When life cycle costs for this process are compared to an alternative three-coal paint system for corrosion protection, the latter costs 5-10 times more than hot-dip galvanizing. An AEP Power Plant in San Juan, Puerto Rico and the McDuffie Coal Terminal in Mobile, AL, USA have both used hot-dip galvanized steel. 1 fig., 1 tab.

Hansen, T.

2006-11-15T23:59:59.000Z

58

Sandra Bruce | Department of Energy  

NLE Websites -- All DOE Office Websites (Extended Search)

Sandra Bruce Sandra Bruce About Us Sandra Bruce - Assistant Inspector General for Inspections Ms. Bruce became the Assistant Inspector General for Inspections in November 2009. She has full leadership responsibility for all aspects of the programs, operations, and policies of the Office of Inspector General's Office of Inspections. Ms. Bruce leads a professional staff located in four geographical locations. Prior to joining Department of Energy's Office of Inspector General, she worked at the National Geospatial-Intelligence Agency (NGA). While with NGA, Ms. Bruce established its first Inspections Office with national responsibility in the areas of program reviews, inspections and intelligence operations. Also, from 1980 to 2003, she served as an auditor with the U.S. Army Audit Agency and the U.S. Postal Service Office of

59

Efficiency and Environmental Impacts of Electricity Restructuring on Coal-fired Power Plants  

E-Print Network (OSTI)

and states in the Northeast was high electricity prices, reflecting high historical average costs from efficiency, cost of coal purchases, and utilization among coal-fired power plants using a panel data set from recent years allows us to examine longer term impacts of restructuring; (2) the focus on coal-fired power

60

Characterizing Coal-Fired Power Plant Mercury Emissions Variability at Low Concentrations  

Science Conference Proceedings (OSTI)

This technical update presents a further evaluation of the variability of mercury emission from coal-fired power plants, based on additional measurements by continuous mercury monitors (CMMs) at two coal-fired power plants with low-level mercury emissions. Emissions variability is important for control technology selection as well as regulatory considerations.

2003-10-20T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Dating of coal fires in Xinjiang, north-west China Xiangmin Zhang,1  

E-Print Network (OSTI)

Dating of coal fires in Xinjiang, north-west China Xiangmin Zhang,1 Salomon B. Kroonenberg2 and Cor, the Netherlands Introduction Coal fires are one of the most serious problems for the Chinese coal indus- try. The estimated annual loss of coal by fires in China ranges from about 10­20 million tonnes (Guan et al., 1998

Utrecht, Universiteit

62

Does proximity to coal-fired power plants influence fish tissue mercury?  

E-Print Network (OSTI)

Does proximity to coal-fired power plants influence fish tissue mercury? Dana K. Sackett · D. Derek+Business Media, LLC 2010 Abstract Much of the mercury contamination in aquatic biota originates from coal of contaminated fish. In this study, we quantified the relative importance of proximity to coal-fired power plants

63

Evaluating the environmental impact of coal-fired power plants through wastewater pollutant vector  

Science Conference Proceedings (OSTI)

Reliable and safe operation of a coal-fired power plant is strongly linked to freshwater resources, and environmental problems related to water source and wastewater discharging are challenging the power plant operation. This study deals with an evaluation ... Keywords: coal-fired power plant, environmental impact, pollutant vector, wastewater

Nikos E. Mastorakis; Andreea Jeles; Cornelia A. Bulucea; Carmen A. Bulucea; Constantin Brindusa

2011-07-01T23:59:59.000Z

64

DETECTION OF EVENTS CAUSING PLUGGAGE OF A COAL-FIRED BOILER: A DATA MINING  

E-Print Network (OSTI)

DETECTION OF EVENTS CAUSING PLUGGAGE OF A COAL-FIRED BOILER: A DATA MINING APPROACH ANDREW KUSIAK to analyze events leading to plug- gage of a boiler. The proposed approach involves statistics, data. The proposed approach has been tested on a 750 MW commercial coal-fired boiler affected with an ash fouling

Kusiak, Andrew

65

COMBINATION OF MSWC AND COAL FIRED POWER PLANT Jiirgen Vehlow, Hans Hunsinger, Siegfried Kreisz, Helmut Seifert  

E-Print Network (OSTI)

COMBINATION OF MSWC AND COAL FIRED POWER PLANT Jiirgen Vehlow, Hans Hunsinger, Siegfried Kreisz for the combination of a municipal solid waste combustion plant and a coal fired power plant in such a way that the dedusted and pre cleaned offgas of the waste combustion serves as carrier gas for the pulverized coal

Columbia University

66

Assessing the environmental pollutant vector of combustion gases emission from coal-fired power plants  

Science Conference Proceedings (OSTI)

Within the present industrial metabolism, electric and thermal energy production is one of the main consumers of fossil fuels. Coal is a natural resource and fossil fuel used in the coal-fired power plants in Romania. Unfortunately, beyond the environmental ... Keywords: coal-fired power plant, combustion gases, environmental impact, pollutant vector

Cornelia A. Bulucea; Andreea Jeles; Nikos E. Mastorakis; Carmen A. Bulucea; Constantin Brindusa

2011-07-01T23:59:59.000Z

67

Research on Resource Value Flow Accounting Based on Circular Economy for Coal-fired Power Plant  

Science Conference Proceedings (OSTI)

This paper presents the methodology of resource value flow accounting developed for a study which combined material flow analysis?MFA? for the coal-fired power generation plant, in order to shed light on concepts such as resource productivity ... Keywords: Circular economy, Coal-fired power plant, Material flow analysis, Resource value flow accounting

Xie Zhiming; Yi Xuan

2010-05-01T23:59:59.000Z

68

FUEL LEAN BIOMASS REBURNING IN COAL-FIRED BOILERS  

DOE Green Energy (OSTI)

This final technical report describes research conducted between July 1, 2000, and June 30, 2002, for the project entitled ''Fuel Lean Biomass Reburning in Coal-Fired Boilers,'' DOE Award No. DE-FG26-00NT40811. Fuel Lean Biomass Reburning is a method of staging fuel within a coal-fired utility boiler to convert nitrogen oxides (NOx) to nitrogen by creating locally fuel-rich eddies, which favor the reduction of NOx, within an overall fuel lean boiler. These eddies are created by injecting a supplemental fuel source, designated as the reburn fuel, downstream of the primary combustion zone. Chopped biomass was the reburn fuel for this project. Four parameters were explored in this research: the initial oxygen concentration ranged between 1%-6%, the amount of biomass used as the reburn fuel ranged between from 0%-23% of the total % energy input, the types of biomass used were low nitrogen switchgrass and high nitrogen alfalfa, and the types of carrier gases used to inject the biomass (nitrogen and steam). Temperature profiles and final flue gas species concentrations are presented in this report. An economic evaluation of a potential full-scale installation of a Fuel-Lean Biomass Reburn system using biomass-water slurry was also performed.

Jeffrey J. Sweterlitsch; Robert C. Brown

2002-07-01T23:59:59.000Z

69

Controlling mercury emissions from coal-fired power plants  

Science Conference Proceedings (OSTI)

Increasingly stringent US federal and state limits on mercury emissions form coal-fired power plants demand optimal mercury control technologies. This article summarises the successful removal of mercury emissions achieved with activated carbon injection and boiler bromide addition, technologies nearing commercial readiness, as well as several novel control concepts currently under development. It also discusses some of the issues standing in the way of confident performance and cost predictions. In testing conducted on western coal-fired units with fabric filters or TOXECON to date, ACI has generally achieved mercury removal rates > 90%. At units with ESPs, similar performance requires brominated ACI. Alternatively, units firing western coals can use boiler bromide addition to increase flue gas mercury oxidation and downstream capture in a wet scrubber, or to enhance mercury removal by ACI. At eastern bituminous fired units with ESPs, ACI is not as effective, largely due to SO{sub 3} resulting from the high sulfur content of the coal or the use of SO{sub 3} flue gas conditioning to improve ESP performance. 7 refs., 3 figs.

Chang, R. [Electric Power Research Institute, Palo Alto, CA (United States)

2009-07-15T23:59:59.000Z

70

FUEL LEAN BIOMASS REBURNING IN COAL-FIRED BOILERS  

SciTech Connect

This final technical report describes research conducted between July 1, 2000, and June 30, 2002, for the project entitled ''Fuel Lean Biomass Reburning in Coal-Fired Boilers,'' DOE Award No. DE-FG26-00NT40811. Fuel Lean Biomass Reburning is a method of staging fuel within a coal-fired utility boiler to convert nitrogen oxides (NOx) to nitrogen by creating locally fuel-rich eddies, which favor the reduction of NOx, within an overall fuel lean boiler. These eddies are created by injecting a supplemental fuel source, designated as the reburn fuel, downstream of the primary combustion zone. Chopped biomass was the reburn fuel for this project. Four parameters were explored in this research: the initial oxygen concentration ranged between 1%-6%, the amount of biomass used as the reburn fuel ranged between from 0%-23% of the total % energy input, the types of biomass used were low nitrogen switchgrass and high nitrogen alfalfa, and the types of carrier gases used to inject the biomass (nitrogen and steam). Temperature profiles and final flue gas species concentrations are presented in this report. An economic evaluation of a potential full-scale installation of a Fuel-Lean Biomass Reburn system using biomass-water slurry was also performed.

Jeffrey J. Sweterlitsch; Robert C. Brown

2002-07-01T23:59:59.000Z

71

Heat pipe technology for coal-fired power systems  

SciTech Connect

This report summarizes the results of heat pipe R and D activities at Argonne National Laboratory (ANL) during the 1977 to 1984 time period. The heat pipe development efforts were associated with a variety of DOE supported projects involving coal-fired prime movers for stationary power generation. The role of heat pipes for these power systems is in their potential application as thermal transport systems for integrating fluidized bed combustors (FBC) with prime movers ranging from Stirling engines in total energy systems (approx.10 MWe) to closed-cycle gas turbines in central power plants (approx.1000 MWe). The results of initial investigations at ANL demonstrated that high-temperature sodium heat pipes provided the best heat exchanger technology for integrating Stirling engines with coal-fired FBC systems. A major accomplishment included the development and validation of a computer code (ANL/HTP) which calculates heat pipe operating limits and other significant characteristics necessary for power plant design. A number of developmental and prototype heat pipes were designed and fabricated through a subcontract effort with Thermacore, Inc., and delivered to ANL for performance testing. Preliminary test results from ANL's Heat Pipe Test Facility, using induction heating and a gas-water calorimeter to establish energy balances, are given in the report. Test data obtained to date are consistent with ANL/HTP code predictions. 47 refs., 53 figs., 22 tabs.

Uherka, K.L.; Holtz, R.E.; McLennan, G.A.; Koehl, E.R.

1985-04-01T23:59:59.000Z

72

Nitrogen Isotopic Composition of Coal-Fired Power Plant NOx: Influence of Emission Controls and Implications for Global Emission  

E-Print Network (OSTI)

Nitrogen Isotopic Composition of Coal-Fired Power Plant NOx: Influence of Emission Controls from coal-fired power plants in the U.S. at typical operating conditions with and without the presence this, a novel method for collection and isotopic analysis of coal-fired stack NOx emission samples

Elliott, Emily M.

73

DOEEA-1183 ENVIRONMENTAL ASSESSMENT COAL-FIRED DIESEL GENERATOR  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

83 83 ENVIRONMENTAL ASSESSMENT COAL-FIRED DIESEL GENERATOR UNIVERSITY OF ALASKA FAIRBANKS, ALASKA MAY 1997 ~S~RIBUTION OF THIS DOCUMENT IS UNLIM&~ U.S. DEPARTMENT OF ENERGY FEDERAL ENERGY TECHNOLOGY CENTER DISCLAIMER This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, make any warranty, express or implied, or assumes any legal liabdi- ty or responsibility for the aawacy, completeness, or usefulness of any information, appa- ratus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by

74

Modeling of a coal-fired natural circulation boiler  

SciTech Connect

Modeling of a natural circulation boiler for a coal-fired thermal power station is presented here. The boiler system is divided into seven subcomponents, and for each section, models based on conservation of mass, momentum, and energy are formulated. The pressure drop at various sections and the heat transfer coefficients are computed using empirical correlations. Solutions are obtained by using SIMULINK. The model is validated by comparing its steady state and dynamic responses with the actual plant data. Open loop responses of the model to the step changes in the operating parameters, such as pressure, temperature, steam flow, feed water flow, are also analyzed. The present model can be used for the development and design of effective boiler control systems.

Bhambare, K.S.; Mitra, S.K.; Gaitonde, U.N. [Indian Institute of Technology, Bombay (India). Dept. of Mechanical Engineering

2007-06-15T23:59:59.000Z

75

Repowering a small coal-fired power plant  

Science Conference Proceedings (OSTI)

The Arkansas River Power Authority (ARPA) Lamar Repowering Project is moving forward. The new generator, capable of producing 18 MW of electricity, is scheduled to be online in June 2008 bringing the total generation to 43 MW. New coal handling equipment, with infrared fire detectors, is almost complete. The new 18 MW steam turbine will be cooled by an air-cooled condenser. Coal will be delivered in a railroad spur to an unloading site then be unloaded onto a conveyor under the tracks and conveyed to two storage domes each holding 6000 tons of coal. It will be drawn out of these through an underground conveyor system, brought into a crusher, conveyed through overhead conveyors and fed into the new coal- fired fluidized bed boilers. 1 photo.

Miell, R.

2007-11-15T23:59:59.000Z

76

Slag processing system for direct coal-fired gas turbines  

SciTech Connect

Direct coal-fired gas turbine systems and methods for their operation are provided by this invention. The gas turbine system includes a primary zone for burning coal in the presence of compressed air to produce hot combustion gases and debris, such as molten slag. The turbine system further includes a secondary combustion zone for the lean combustion of the hot combustion gases. The operation of the system is improved by the addition of a cyclone separator for removing debris from the hot combustion gases. The cyclone separator is disposed between the primary and secondary combustion zones and is in pressurized communication with these zones. In a novel aspect of the invention, the cyclone separator includes an integrally disposed impact separator for at least separating a portion of the molten slag from the hot combustion gases.

Pillsbury, Paul W. (Winter Springs, FL)

1990-01-01T23:59:59.000Z

77

2 COUNTRIES WITH SIGNIFICANT COAL-FIRED GENERATING CAPACITY..................5  

E-Print Network (OSTI)

This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference therein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed therein do not necessarily state or reflect those of the United States Government or any agency thereof. Reducing Water Freshwater Consumption at Coal-Fired Power Plants:

At Coal-fired Power Plants; Barbara Carney

2011-01-01T23:59:59.000Z

78

Southern thailand coal fired project: Feasibility study. Export trade information  

SciTech Connect

This study, conducted by Black & Veatch International, was funded by the U.S. Trade and Development Agency. The report addresses various technical, environmental, and economic aspects of developing four 1,000 MW units of coal fired electric generating facilities at a site near Prachuap Khiri Khan. The study includes a cost estimate for the units and the fuel delivery port as well as the major conceptual design decisions made for the project. This volume of the report is the Feasibility Study and is divided into the following sections: (1) Introduction/Summary; (2) Generation Planning Study; (3) Site Selection Study; (4) Project Description; (5) Fuel Resource Assessment; (6) Water Resource Assessment; (7) Technical Information to Support the Environmental Impact Assessment; (8) Plant Conceptual Design; (9) Transmission Interconnection; (10) Project Capital Cost Estimate; (11) Project Schedule; (12) Project Implementation Plan; (13) Project Risk Analysis.

1995-09-01T23:59:59.000Z

79

Impacts of TMDLs on coal-fired power plants.  

SciTech Connect

The Clean Water Act (CWA) includes as one of its goals restoration and maintenance of the chemical, physical, and biological integrity of the Nation's waters. The CWA established various programs to accomplish that goal. Among the programs is a requirement for states to establish water quality standards that will allow protection of the designated uses assigned to each water body. Once those standards are set, state agencies must sample the water bodies to determine if water quality requirements are being met. For those water bodies that are not achieving the desired water quality, the state agencies are expected to develop total maximum daily loads (TMDLs) that outline the maximum amount of each pollutant that can be discharged to the water body and still maintain acceptable water quality. The total load is then allocated to the existing point and nonpoint sources, with some allocation held in reserve as a margin of safety. Many states have already developed and implemented TMDLs for individual water bodies or regional areas. New and revised TMDLs are anticipated, however, as federal and state regulators continue their examination of water quality across the United States and the need for new or revised standards. This report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Existing Plants Research Program, which has an energy-water research effort that focuses on water use at power plants. This study complements its overall research effort by evaluating water issues that could impact power plants. One of the program missions of the DOE's NETL is to develop innovative environmental control technologies that will enable full use of the Nation's vast coal reserves, while at the same time allowing the current fleet of coal-fired power plants to comply with existing and emerging environmental regulations. Some of the parameters for which TMDLs are being developed are components in discharges from coal-fired power plants. If a state establishes a new or revised TMDL for one of these pollutants in a water body where a power plant is located, the next renewal of the power plant's National Pollution Discharge Elimination System (NPDES) permit is likely to include more restrictive limits. Power generators may need to modify existing operational and wastewater treatment technologies or employ new ones as TMDLs are revised or new ones are established. The extent to which coal-fired power plants may be impacted by revised and new TMDL development has not been well established. NETL asked Argonne to evaluate how current and potential future TMDLs might influence coal-fired power plant operations and discharges. This information can be used to inform future technology research funded by NETL. The scope of investigation was limited to several eastern U.S. river basins rather than providing a detailed national perspective.

Veil, J. A.; Environmental Science Division

2010-04-30T23:59:59.000Z

80

COAL-FIRED UTILITY BOILERS: SOLVING ASH DEPOSITION PROBLEMS  

SciTech Connect

The accumulation of slagging and fouling ash deposits in utility boilers has been a source of aggravation for coal-fired boiler operators for over a century. Many new developments in analytical, modeling, and combustion testing methods in the past 20 years have made it possible to identify root causes of ash deposition. A concise and comprehensive guidelines document has been assembled for solving ash deposition as related to coal-fired utility boilers. While this report accurately captures the current state of knowledge in ash deposition, note that substantial research and development is under way to more completely understand and mitigate slagging and fouling. Thus, while comprehensive, this document carries the title ''interim,'' with the idea that future work will provide additional insight. Primary target audiences include utility operators and engineers who face plant inefficiencies and significant operational and maintenance costs that are associated with ash deposition problems. Pulverized and cyclone-fired coal boilers are addressed specifically, although many of the diagnostics and solutions apply to other boiler types. Logic diagrams, ash deposit types, and boiler symptoms of ash deposition are used to aid the user in identifying an ash deposition problem, diagnosing and verifying root causes, determining remedial measures to alleviate or eliminate the problem, and then monitoring the situation to verify that the problem has been solved. In addition to a step-by-step method for identifying and remediating ash deposition problems, this guideline document (Appendix A) provides descriptions of analytical techniques for diagnostic testing and gives extensive fundamental and practical literature references and addresses of organizations that can provide help in alleviating ash deposition problems.

Christopher J. Zygarlicke; Donald P. McCollor; Steven A. Benson; Jay R. Gunderson

2001-04-01T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

Oxides Emissions from Coal-Fired Boilers TOPICAL REPORT NUMBER 14  

NLE Websites -- All DOE Office Websites (Extended Search)

Reburning Technologies for the Control of Nitrogen Reburning Technologies for the Control of Nitrogen Oxides Emissions from Coal-Fired Boilers TOPICAL REPORT NUMBER 14 MAY 1999 TOPICAL REPORT NUMBER 14 A report on three projects conducted under separate cooperative agreements between: The U.S. Department of Energy and * The Babcock & Wilcox Company * Energy and Environmental Research Corporation * New York State Electric & Gas Corporation MAY 1999 Reburning Technologies for the Control of Nitrogen Oxides Emissions from Coal-Fired Boilers Cover image: Schematic of reburning technology Source: Energy and Environmental Research Corporation Reburning Technologies for the Control of Nitrogen Oxides Emissions from Coal-Fired Boilers Executive Summary ..................................................................................................

82

Projected retirements of coal-fired power plants - Today in Energy ...  

U.S. Energy Information Administration (EIA)

Current trends in the electric power market put many coal-fired generators in the United States at risk for retirement. In the Annual Energy Outlook 2012 (AEO2012 ...

83

Workers Demolish Coal-fired Steam Plant at EM's Portsmouth Site |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Workers Demolish Coal-fired Steam Plant at EM's Portsmouth Site Workers Demolish Coal-fired Steam Plant at EM's Portsmouth Site Workers Demolish Coal-fired Steam Plant at EM's Portsmouth Site September 18, 2013 - 12:00pm Addthis A high-pressure water cannon is used to control dust for the demolition of the X-600 Steam Plant. A high-pressure water cannon is used to control dust for the demolition of the X-600 Steam Plant. One of three large smoke stacks comes down during the demolition. One of three large smoke stacks comes down during the demolition. A high-pressure water cannon is used to control dust for the demolition of the X-600 Steam Plant. One of three large smoke stacks comes down during the demolition. PIKETON, Ohio - Towering above most nearby buildings, the X-600 Coal-fired Steam Plant had been part of the Portsmouth Gaseous Diffusion

84

Workers Demolish Coal-fired Steam Plant at EM's Portsmouth Site |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Workers Demolish Coal-fired Steam Plant at EM's Portsmouth Site Workers Demolish Coal-fired Steam Plant at EM's Portsmouth Site Workers Demolish Coal-fired Steam Plant at EM's Portsmouth Site September 18, 2013 - 12:00pm Addthis A high-pressure water cannon is used to control dust for the demolition of the X-600 Steam Plant. A high-pressure water cannon is used to control dust for the demolition of the X-600 Steam Plant. One of three large smoke stacks comes down during the demolition. One of three large smoke stacks comes down during the demolition. A high-pressure water cannon is used to control dust for the demolition of the X-600 Steam Plant. One of three large smoke stacks comes down during the demolition. PIKETON, Ohio - Towering above most nearby buildings, the X-600 Coal-fired Steam Plant had been part of the Portsmouth Gaseous Diffusion

85

Prestigious Coal-Fired Project of the Year Award Goes to Plant  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Prestigious Coal-Fired Project of the Year Award Goes to Plant Prestigious Coal-Fired Project of the Year Award Goes to Plant Demonstrating Innovative DOE-Funded Technology Prestigious Coal-Fired Project of the Year Award Goes to Plant Demonstrating Innovative DOE-Funded Technology December 16, 2010 - 12:00pm Addthis Washington, DC - An innovative project demonstrating DryFining™ technology, a more cost-effective way to control coal-based power plant emissions while improving fuel quality, has been named the 2010 Coal-Fired Project of the Year by the editors of Power Engineering magazine. The project, managed by the Office of Fossil Energy's National Energy Technology Laboratory, was developed with funding from the Department of Energy's Clean Coal Power Initiative and was originally implemented at Great River Energy's Coal Creek Station in Underwood, ND, in 2009. The

86

Characterizing Variation in Mercury Emissions from Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

This report evaluates the variability of mercury emissions from coal-fired power plants, using EPRI's continuous mercury monitor (CMM) dataset. Emission variability is important for control technology selection as well as regulatory considerations.

2003-06-03T23:59:59.000Z

87

Carbon dioxide capture from coal-fired power plants : a real potions analysis  

E-Print Network (OSTI)

Investments in three coal-fired power generation technologies are valued using the "real options" valuation methodology in an uncertain carbon dioxide (CO2) price environment. The technologies evaluated are pulverized coal ...

Sekar, Ram Chandra

2005-01-01T23:59:59.000Z

88

NETL: News Release - New Mexico Coal-Fired Power Plant to Demonstrate...  

NLE Websites -- All DOE Office Websites (Extended Search)

October 14, 2004 New Mexico Coal-Fired Power Plant to Demonstrate Multi-Pollutant Controls Project Will Help Meet President's Commitment to Clean Coal and Address National Energy...

89

Effect of the shutdown of a large coal-fired power plant on ambient...  

NLE Websites -- All DOE Office Websites (Extended Search)

Effect of the shutdown of a large coal-fired power plant on ambient mercury species Yungang Wang 1 , Jiaoyan Huang 2,a , Philip K. Hopke 3,* , Oliver V. Rattigan 4 , David C....

90

Large Field Erected and Packaged High Temperature Water (HTW) Generators for Coal Firing  

E-Print Network (OSTI)

The purpose of the paper is to disseminate information on the energy savings possible with High Temperature Water (HTW) for heating and industrial process application and to provide information on coal fired HTW generator design and availability.

Boushell, C. C.

1980-01-01T23:59:59.000Z

91

MHD coal-fired flow facility. Annual technical progress report, October 1979-September 1980  

DOE Green Energy (OSTI)

The University of Tennessee Space Institute (UTSI) reports on significant activity, task status, planned research, testing, development, and conclusions for the Magnetohydrodynamics (MHD) Coal-Fired Flow Faclity (CFFF) and the Energy Conversion Facility (ECF).

Alstatt, M.C.; Attig, R.C.; Brosnan, D.A.

1981-03-01T23:59:59.000Z

92

SO2 impacts on forage and soil sulfur concentrations near coal-fired power plants.  

E-Print Network (OSTI)

??The goal of this research was to determine if S02 emissions from coal-fired power plants could be contributing to the copper deficiency in cattle. Copper (more)

Beene, Jack Stephen

2012-01-01T23:59:59.000Z

93

Water vulnerabilities for existing coal-fired power plants.  

SciTech Connect

This report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Existing Plants Research Program, which has an energy-water research effort that focuses on water use at power plants. This study complements the Existing Plants Research Program's overall research effort by evaluating water issues that could impact power plants. Water consumption by all users in the United States over the 2005-2030 time period is projected to increase by about 7% (from about 108 billion gallons per day [bgd] to about 115 bgd) (Elcock 2010). By contrast, water consumption by coal-fired power plants over this period is projected to increase by about 21% (from about 2.4 to about 2.9 bgd) (NETL 2009b). The high projected demand for water by power plants, which is expected to increase even further as carbon-capture equipment is installed, combined with decreasing freshwater supplies in many areas, suggests that certain coal-fired plants may be particularly vulnerable to potential water demand-supply conflicts. If not addressed, these conflicts could limit power generation and lead to power disruptions or increased consumer costs. The identification of existing coal-fired plants that are vulnerable to water demand and supply concerns, along with an analysis of information about their cooling systems and related characteristics, provides information to help focus future research and development (R&D) efforts to help ensure that coal-fired generation demands are met in a cost-effective manner that supports sustainable water use. This study identified coal-fired power plants that are considered vulnerable to water demand and supply issues by using a geographical information system (GIS) that facilitated the analysis of plant-specific data for more than 500 plants in the NETL's Coal Power Plant Database (CPPDB) (NETL 2007a) simultaneously with 18 indicators of water demand and supply. Two types of demand indicators were evaluated. The first type consisted of geographical areas where specific conditions can generate demand vulnerabilities. These conditions include high projected future water consumption by thermoelectric power plants, high projected future water consumption by all users, high rates of water withdrawal per square mile (mi{sup 2}), high projected population increases, and areas projected to be in a water crisis or conflict by 2025. The second type of demand indicator was plant specific. These indicators were developed for each plant and include annual water consumption and withdrawal rates and intensities, net annual power generation, and carbon dioxide (CO{sub 2}) emissions. The supply indictors, which are also area based, include areas with low precipitation, high temperatures, low streamflow, and drought. The indicator data, which were in various formats (e.g., maps, tables, raw numbers) were converted to a GIS format and stored, along with the individual plant data from the CPPDB, in a single GIS database. The GIS database allowed the indicator data and plant data to be analyzed and visualized in any combination. To determine the extent to which a plant would be considered 'vulnerable' to a given demand or supply concern (i.e., that the plant's operations could be affected by water shortages represented by a potential demand or supply indicator), criteria were developed to categorize vulnerability according to one of three types: major, moderate, or not vulnerable. Plants with at least two major demand indicator values and/or at least four moderate demand indicator values were considered vulnerable to demand concerns. By using this approach, 144 plants were identified as being subject to demand concerns only. Plants with at least one major supply indicator value and/or at least two moderate supply indicator values were considered vulnerable to supply concerns. By using this approach, 64 plants were identified as being subject to supply concerns only. In addition, 139 plants were identified as subject to both demand and supply concerns. Therefore, a total of 347 plants were considere

Elcock, D.; Kuiper, J.; Environmental Science Division

2010-08-19T23:59:59.000Z

94

Catalyst Management Handbook for Coal-Fired Selective Catalytic Reduction NOx Control  

Science Conference Proceedings (OSTI)

This report provides guidelines for operators of coal-fired power plants equipped with selective catalytic reduction (SCR) NOx-control processes. These control processes define when to exchange or replace catalyst, while minimizing power-production cost impacts from SCR process equipment.BackgroundSelective catalytic reduction (SCR) is deployed on most major coal-fired generating units in the United States. Over 225 units, totaling 140 GW of ...

2012-12-14T23:59:59.000Z

95

Estimation Methodology for Total and Elemental Mercury Emissions from Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

This report provides a tool for estimating total and speciated mercury emissions from coal-fired power plants. The mercury emissions methodology is based on EPRI's analyses of the results from the U.S. Environmental Protection Agency (EPA) Mercury Information Collection Request (ICR). The Mercury ICR required owner/operators of coal-fired electric utility steam generating units to report for calendar year 1999 the quantity of fuel consumed and the mercury content of that fuel. In addition, 84 power plant...

2001-04-18T23:59:59.000Z

96

Sampling and Analytical Plan Guidance for Water Characterization of Coal-Fired Steam Electric Utility Facilities  

Science Conference Proceedings (OSTI)

The US EPA recently announced its intentions to conduct a two-year study to determine whether the Steam Electric Categorical Effluent Guidelines should be revised. This report provides sampling plan guidance designed to assist the EPA in developing a sampling program and site-specific sampling plans to characterize a coal-fired facility's wastewater, to include some sampling processes used by EPRI in past coal-fired wastewater characterization studies, and to assist EPA in ensuring data quality during it...

2007-06-21T23:59:59.000Z

97

An Assessment of Mercury Emissions from U.S. Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

In parallel with a U.S. Environmental Protection Agency (EPA) study of mercury emissions from coal-fired electric utility steam generating units, EPRI has reviewed the available data and re-estimated mercury emissions. This document provides an estimate of the mercury levels entering every U.S. coal-fired power plant in 1999, the total and speciated mercury emissions during the same period, and initial projections of the effect of operational and design changes on mercury levels in 2010.

2000-10-10T23:59:59.000Z

98

Options for Removing Multiple Pollutants Including CO2 at Existing Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

This report is a technical review of the fuel changes and technology options for existing coal-fired power plants in response to potential new requirements for increasingly stringent multi-pollutant air emissions reductions, possibly including carbon dioxide (CO2). Preliminary costing of the major options is included. A database of the U.S. coal-fired power plants has been developed for further, more specific analyses.

2002-10-08T23:59:59.000Z

99

Characterization of the Toxicity of Coal-Fired Power Plant Effluents to Freshwater Mussels  

Science Conference Proceedings (OSTI)

Coal-fired power plant effluents contain trace metals, dissolved salts, and nutrients that may harm aquatic life, including fish, invertebrates, and freshwater mussels, living in receiving streams adjacent to the plants. This interim report discusses the results of effluent toxicity and water quality tests performed over the past year for three coal-fired power plantsMitchell Plant and Mountaineer Plant, both in West Virginia, and Marshall Plant in North Carolina.

2011-12-08T23:59:59.000Z

100

City of Mansfield, Missouri (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Mansfield Mansfield Place Missouri Utility Id 11585 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Special Rate- Engrave-A-Crete Industrial Special Rate- Hutchens Industries Industrial Special Rate- SE-MA-NO Electric Commercial Average Rates Residential: $0.0975/kWh Commercial: $0.1000/kWh Industrial: $0.0769/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a" Retrieved from "http://en.openei.org/w/index.php?title=City_of_Mansfield,_Missouri_(Utility_Company)&oldid=409908

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

City of Mansfield, Georgia (Utility Company) | Open Energy Information  

Open Energy Info (EERE)

Mansfield, Georgia (Utility Company) Mansfield, Georgia (Utility Company) Jump to: navigation, search Name City of Mansfield Place Georgia Utility Id 11587 Utility Location Yes Ownership M NERC Location SERC NERC SERC Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png Commercial Electric Rates Commercial Commercial Outdoor Light Rates Lighting Residential Electric Rates Residential Outdoor light Rates Lighting Average Rates Residential: $0.1120/kWh Commercial: $0.1170/kWh Industrial: $0.1090/kWh References ↑ "EIA Form EIA-861 Final Data File for 2010 - File1_a"

102

Testing of a coal-fired diesel power plant  

DOE Green Energy (OSTI)

The POC coal-fired power plant consists of a Cooper-Bessemer LSC-6 engine (15.5 inch bore, 22 inch stroke) rated at 400 rev/min and 208 psi bmep producing approximately 1.8 MW of power. The power plant is fueled with 'engine grade' coal slurry which has been physically cleaned to an ash level of approximately 1.5 to 2% (dry basis) and has a mean particle size of approximately 12 micron. CWS is injected directly into the combustion chamber through a fuel injector (one per cylinder) which was designed and developed to be compatible with the fuel. Each injector is fitted with a 19 orifice nozzle tip made with sapphire inserts in each orifice. The combustion chambers are fitted with twin diesel pilot injectors which provide a positive ignition source and substantially shorten the ignition delay period of the CWS fuel. Durable coatings (typically tungsten carbide) are used for the piston rings and cylinder liners to reduce wear rates. The emission control system consists of SCR for NO[sub x] control, sodium sorbent injection for SO[sub x] control, and a cyclone plus baghouse for particulate capture. The cyclone is installed upstream of the engine turbocharger which helps protect the turbine blades.

Wilson, R.P.; Balles, E.N.; Benedek, K.R.; Benson, C.E. (Little (Arthur D.), Inc., Cambridge, MA (United States)); Rao, K.; Schaub, F. (Cooper-Bessemer, Mount Vernon, OH (United States)); Kimberley, J. (AMBAC, West Springfield, MA (United States)); Itse, D. (PSI Technology Co., Andover, MA (United States))

1993-01-01T23:59:59.000Z

103

Testing of a coal-fired diesel power plant  

DOE Green Energy (OSTI)

The POC coal-fired power plant consists of a Cooper-Bessemer LSC-6 engine (15.5 inch bore, 22 inch stroke) rated at 400 rev/min and 208 psi bmep producing approximately 1.8 MW of power. The power plant is fueled with `engine grade` coal slurry which has been physically cleaned to an ash level of approximately 1.5 to 2% (dry basis) and has a mean particle size of approximately 12 micron. CWS is injected directly into the combustion chamber through a fuel injector (one per cylinder) which was designed and developed to be compatible with the fuel. Each injector is fitted with a 19 orifice nozzle tip made with sapphire inserts in each orifice. The combustion chambers are fitted with twin diesel pilot injectors which provide a positive ignition source and substantially shorten the ignition delay period of the CWS fuel. Durable coatings (typically tungsten carbide) are used for the piston rings and cylinder liners to reduce wear rates. The emission control system consists of SCR for NO{sub x} control, sodium sorbent injection for SO{sub x} control, and a cyclone plus baghouse for particulate capture. The cyclone is installed upstream of the engine turbocharger which helps protect the turbine blades.

Wilson, R.P.; Balles, E.N.; Benedek, K.R.; Benson, C.E. [Little (Arthur D.), Inc., Cambridge, MA (United States); Rao, K.; Schaub, F. [Cooper-Bessemer, Mount Vernon, OH (United States); Kimberley, J. [AMBAC, West Springfield, MA (United States); Itse, D. [PSI Technology Co., Andover, MA (United States)

1993-01-01T23:59:59.000Z

104

for Coal-Fired Power Plants, 1970-2000  

E-Print Network (OSTI)

This paper relies on interviews and documentary evidence to describe federal RD&D policy for SO2 and NOx emissions controls for coal-fired power plants from 1970 to 2000 and to assess its impact on technology development. The narrative begins by describing the RD&D program of the EPA in the 1970s, which many observers deem to have been successful, but which was largely dismantled after the election of Ronald Reagan to the presidency in 1980. We then turn to the contributions of the U.S. Department of Energy (DOE), which has been the main federal agency operating in this area since 1980, and particularly to DOEs Clean Coal Technology Demonstration Program (CCTDP), which began in 1985. The narrative as a whole suggests a mixed verdict on the effectiveness of past federal emissions control RD&D. In the papers conclusion, we mine this narrative history for insights that may be useful to current policy-makers. We argue first that regulatory pull is a necessary component for an effective greenhouse gas reduction policy, while technology push is not. However, a welldesigned technology push may enhance the impact of regulation and lower the cost of compliance. Second, we should not expect that these two components will be well-aligned, due

David M. Hart; Kadri Kallas; David M. Hart; Kadri Kallas

2010-01-01T23:59:59.000Z

105

Investigating the effects of the 1990 Clean Air Act Amendments on inputs to coal-fired power plants.  

E-Print Network (OSTI)

??This dissertation examines the effects of the 1990 Clean Air Act Amendments (CAAA) on inputs to coal-fired power plants. The 1990 CAAA established a system (more)

Lange, Ian

2005-01-01T23:59:59.000Z

106

Water Extraction from Coal-Fired Power Plant Flue Gas  

Science Conference Proceedings (OSTI)

The overall objective of this program was to develop a liquid disiccant-based flue gas dehydration process technology to reduce water consumption in coal-fired power plants. The specific objective of the program was to generate sufficient subscale test data and conceptual commercial power plant evaluations to assess process feasibility and merits for commercialization. Currently, coal-fired power plants require access to water sources outside the power plant for several aspects of their operation in addition to steam cycle condensation and process cooling needs. At the present time, there is no practiced method of extracting the usually abundant water found in the power plant stack gas. This project demonstrated the feasibility and merits of a liquid desiccant-based process that can efficiently and economically remove water vapor from the flue gas of fossil fuel-fired power plants to be recycled for in-plant use or exported for clean water conservation. After an extensive literature review, a survey of the available physical and chemical property information on desiccants in conjunction with a weighting scheme developed for this application, three desiccants were selected and tested in a bench-scale system at the Energy and Environmental Research Center (EERC). System performance at the bench scale aided in determining which desiccant was best suited for further evaluation. The results of the bench-scale tests along with further review of the available property data for each of the desiccants resulted in the selection of calcium chloride as the desiccant for testing at the pilot-scale level. Two weeks of testing utilizing natural gas in Test Series I and coal in Test Series II for production of flue gas was conducted with the liquid desiccant dehumidification system (LDDS) designed and built for this study. In general, it was found that the LDDS operated well and could be placed in an automode in which the process would operate with no operator intervention or adjustment. Water produced from this process should require little processing for use, depending on the end application. Test Series II water quality was not as good as that obtained in Test Series I; however, this was believed to be due to a system upset that contaminated the product water system during Test Series II. The amount of water that can be recovered from flue gas with the LDDS is a function of several variables, including desiccant temperature, L/G in the absorber, flash drum pressure, liquid-gas contact method, and desiccant concentration. Corrosion will be an issue with the use of calcium chloride as expected but can be largely mitigated through proper material selection. Integration of the LDDS with either low-grade waste heat and or ground-source heating and cooling can affect the parasitic power draw the LDDS will have on a power plant. Depending on the amount of water to be removed from the flue gas, the system can be designed with no parasitic power draw on the power plant other than pumping loads. This can be accomplished in one scenario by taking advantage of the heat of absorption and the heat of vaporization to provide the necessary temperature changes in the desiccant with the flue gas and precipitates that may form and how to handle them. These questions must be addressed in subsequent testing before scale-up of the process can be confidently completed.

Bruce C. Folkedahl; Greg F. Weber; Michael E. Collings

2006-06-30T23:59:59.000Z

107

Coal-fired high performance power generating system  

SciTech Connect

The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of > 47% thermal efficiency; NO[sub x] SO [sub x] and Particulates < 25% NSPS; Cost of electricity 10% lower; coal > 65% of heat input and all solid wastes benign. In order to achieve these goals our team has outlined a research plan based on an optimized analysis of a 250 MW[sub e] combined cycle system applicable to both frame type and aeroderivative gas turbines. Under the constraints of the cycle analysis we have designed a high temperature advanced furnace (HITAF) which integrates several combustor and air heater designs with appropriate ash management procedures. Most of this report discusses the details of work on these components, and the R D Plan for future work. The discussion of the combustor designs illustrates how detailed modeling can be an effective tool to estimate NO[sub x] production, minimum burnout lengths, combustion temperatures and even particulate impact on the combustor walls. When our model is applied to the long flame concept it indicates that fuel bound nitrogen will limit the range of coals that can use this approach. For high nitrogen coals a rapid mixing, rich-lean, deep staging combustor will be necessary. The air heater design has evolved into two segments: a convective heat exchanger downstream of the combustion process; a radiant panel heat exchanger, located in the combustor walls; The relative amount of heat transferred either radiatively or convectively will depend on the combustor type and the ash properties.

1992-07-01T23:59:59.000Z

108

Operating Experience of a Coal Fired Fluidized Bed at Georgetown University  

E-Print Network (OSTI)

Operation of the 100,000 lb/hr capacity, coal fired fluidized bed steam generator at Georgetown University began in July 1979. This project, which was co-funded by Georgetown University and the U. S. Department of Energy, involved expansion of the heating and cooling plant with this new coal fired facility. Previously existing units at the University heating and cooling plant normally fire natural gas. The fluidized bed steam generating facility at Georgetown University is the only new coal fired facility to be built in the Washington D. C. area in many years. The purpose of this program is to demonstrate industrial and institutional application of fluidized bed combustion using high sulfur coal in an environmentally acceptable manner in a populated area. The unit has been successfully operated for over 1400 hours and in compliance with the strict emission regulations of Washington, D.C. Operation on automatic control has been achieved and only minor operating difficulties have been experienced.

Lutes, I. G.; Gamble, R. L.

1980-01-01T23:59:59.000Z

109

Engineering development of advanced coal-fired low-emission boiler system  

Science Conference Proceedings (OSTI)

The Pittsburgh Energy Technology Center of the US Department of Energy (DOE) has contracted with Combustion Engineering, Inc. (ABB CE) to perform work on the Engineering Development of Advanced Coal-Fired Low-Emission Boiler Systems'' Project and has authorized ABB CE to complete Phase I on a cost-reimbursable basis. The overall objective of the Project is the expedited commercialization of advanced coal-fired low-emission boiler systems. The specified primary objectives are: NO[sub x] emissions not greater than one-third NSPS; SO[sub x] emissions not greater than one-third NSPS; and particulate emissions not greater than one-half NSPS. The specific secondary objectives are: Improved ash disposability and reduced waste generation; reduced air toxics emissions; increased generating efficiency. The final deliverables are a design data base that will allow future coal-fired power plants to meet the stated objectives and a preliminary design of a commercial generation unit.

Not Available

1993-02-26T23:59:59.000Z

110

Exergy efficiency of small coal-fired power plants as a criterion of their wide applicability  

Science Conference Proceedings (OSTI)

The applicability of small coal-fired power plants as an independent and reliable power supply source was considered. The advantages of using small thermal power plants were given, and the classification characteristics of small coal-fired power plants were put forward. The exergy method was chosen as a versatility indicator for the operating efficiency of a flowsheet in question. The exergy efficiency factor of the flowsheet was 32%. With the manufacture of by-products, such as activated carbons, the exergy efficiency of the flowsheet increased to 35%. The studies undertaken substantiated the wide applicability of small coal-fired power plants for the development of decentralized power supply. 7 refs., 2 tabs.

O.V. Afanas'eva; G.R. Mingaleeva [Russian Academy of Sciences, Tatarstan (Russian Federation). Research Center of Power Engineering Problems

2009-02-15T23:59:59.000Z

111

Dispersion modeling of mercury emissions from coal-fired power plants at Coshocton and Manchester, Ohio  

Science Conference Proceedings (OSTI)

Mercury emissions from coal-fired power plants are estimated to contribute to approximately 46% of the total US anthropogenic mercury emissions and required to be regulated by maximum achievable control technology (MACT) standards. Dispersion modeling of mercury emissions using the AERMOD model and the industrial source complex short term (ISCST3) model was conducted for two representative coal-fired power plants at Coshocton and Manchester, Ohio. Atmospheric mercury concentrations, dry mercury deposition rates, and wet mercury deposition rates were predicted in a 5 x 5 km area surrounding the Coonesville and JM Stuart coal-fired power plants. In addition, the analysis results of meteorological parameters showed that wet mercury deposition is dependent on precipitation, but dry mercury deposition is influenced by various meteorological factors. 8 refs., 5 figs., 3 tabs.

Lee, S.; Keener, T.C. [University of Cincinnati, Cincinnati, OH (United States). Dept. of Civil and Environmental Engineering

2009-09-15T23:59:59.000Z

112

Savannah River Site Retires Coal-Fired D-Area Powerhouse after Nearly 60  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Savannah River Site Retires Coal-Fired D-Area Powerhouse after Savannah River Site Retires Coal-Fired D-Area Powerhouse after Nearly 60 Years of Service Savannah River Site Retires Coal-Fired D-Area Powerhouse after Nearly 60 Years of Service May 1, 2012 - 12:00pm Addthis SRNS Maintenance Supervisor Steve Cooper, left to right, Control Room Operator Robert Dicks, and Deputy Operations Manager Ren Hatfield stand near a boiler unit of the DArea powerhouse. The three workers have a combined experience of 83 years at the facility. SRNS Maintenance Supervisor Steve Cooper, left to right, Control Room Operator Robert Dicks, and Deputy Operations Manager Ren Hatfield stand near a boiler unit of the DArea powerhouse. The three workers have a combined experience of 83 years at the facility. AIKEN, S.C. - The Savannah River Site (SRS) has shut down the massive,

113

Cornell's conversion of a coal fired heating plant to natural Gas -BACKGROUND: In December 2009, the Combined Heat and Power Plant  

E-Print Network (OSTI)

Cornell's conversion of a coal fired heating plant to natural Gas University began operating with natural gas, instead of the coal-fired generators of the coal that had been stockpiled, the Plant is running completely on natural gas

Keinan, Alon

114

POLLUTION-CONTROL TECHNOLOGIES IN COAL-FIRED POWER PLANTS AND THEIR IMPACT ON AEROSOL NUCLEATION AND GROWTH IN EMISSIONS PLUMES.  

E-Print Network (OSTI)

??Nucleation and growth of particles in coal-fired power-plant plumes can greatly contribute to particle concentrations near source regions. Pollution-control technologies have been added to coal-fired (more)

Lonsdale, Chantelle

2012-01-01T23:59:59.000Z

115

Accumulation of trace elements and growth responses in Corbicula fluminea downstream of a coal-fired power plant  

E-Print Network (OSTI)

Accumulation of trace elements and growth responses in Corbicula fluminea downstream of a coal 2009 Keywords: Corbicula fluminea Coal-fired power plant Selenium Mercury Glutathione Condition index Bioaccumulation a b s t r a c t Lentic organisms exposed to coal-fired power plant (CFPP) discharges can have

Hopkins, William A.

116

Application of Multi-objects Fuzzy Comprehension Evaluation in Selecting Location of Coal-Fired Plant Construction Project  

Science Conference Proceedings (OSTI)

The paper introduces the method of multi-objects fuzzy comprehension evaluation briefly, and applies it to select location of coal-fired plants construction project. Multi-objective fuzzy comprehensive evaluation in plant site application has strong ... Keywords: Fuzzy comprehension evaluation, Multi-objects decision, Selecting location of coal-fired plant

Li Wei; Zhang Zhen-gang; Wen Xinpu

2008-12-01T23:59:59.000Z

117

Town of Mansfield, Massachusetts (Utility Company) | Open Energy  

Open Energy Info (EERE)

Mansfield Mansfield Place Massachusetts Utility Id 11586 Utility Location Yes Ownership M NERC Location NPCC NERC NPCC Yes Activity Buying Transmission Yes Activity Distribution Yes References EIA Form EIA-861 Final Data File for 2010 - File1_a[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Utility Rate Schedules Grid-background.png BACKUP AND STANDYBY RATE Commercial COMMERCIAL SERVICE RATE Commercial F-1 Firm Transmission Rate Commercial GENERAL SERVICE POWER RATE Commercial GENERAL SERVICE PRIMARY VOLTAGE Commercial NON FIRM TRANSMISSION SERVICE Commercial RATE 49- STREET LIGHTING RATE Lighting RESIDENTIAL SERVICE RATES Residential STANDARD COST CHARGE SCHEDULE Residential

118

Prediction of power output of a coal-fired power plant by artificial neural network  

Science Conference Proceedings (OSTI)

Accurate modeling of thermal power plant is very useful as well as difficult. Conventional simulation programs based on heat and mass balances represent plant processes with mathematical equations. These are good for understanding the processes but usually ... Keywords: ANN model, Coal-fired boiler, Extrapolation, Interpolation, Real plant data, Steam turbine

J. Smrekar; D. Pandit; M. Fast; M. Assadi; Sudipta De

2010-07-01T23:59:59.000Z

119

Cloud-Active Nuclei from Coal-Fired Electric Power Plants and Their Interactions with Clouds  

Science Conference Proceedings (OSTI)

The concentrations of cloud condensation nuclei (CCN) in the plumes from coal-fired electric power plants are generally about 2 to 5 times greater than in the ambient air unaffected by the plumes. However, if the ambient air is very clean, the ...

Peter V. Hobbs; Jeffrey L. Stith; Lawrence F. Radke

1980-04-01T23:59:59.000Z

120

Financing Capture Ready Coal-Fired Power Plants in China by Issuing Capture Options  

E-Print Network (OSTI)

Financing Capture Ready Coal-Fired Power Plants in China by Issuing Capture Options Xi Liang, Jia Li, Jon Gibbons and David Reiner December 2007 EPRG 0728 & CWPE 0761 #12;FINANCING CAPTURE READY COAL supercritical pulverized coal power plant in China, using a cash flow model with Monte-Carlo simulations

Aickelin, Uwe

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Component Failure and Repair Data for Coal-Fired Power Units  

Science Conference Proceedings (OSTI)

A complete and consistent set of failure rate and time-to-restore data for components of a coal-fired generating unit was developed for use in the validation of a reliability and availability assessment model. This report presents the data and describes the principal methodology used--a failure modes analysis. It also includes process flow diagrams.

1981-10-01T23:59:59.000Z

122

Modification of boiler operating conditions for mercury emissions reductions in coal-fired utility boilers  

E-Print Network (OSTI)

Modification of boiler operating conditions for mercury emissions reductions in coal-fired utility boilers Carlos E. Romero *, Ying Li, Harun Bilirgen, Nenad Sarunac, Edward K. Levy Energy Research Center type, boiler operation, fly ash characteristics and type of environmental control equipment installed

Li, Ying

123

Recent coal-fire and land-use status of Jharia Coalfield, India from satellite data  

Science Conference Proceedings (OSTI)

The Jharia Coalfield (JCF) in India is known for its high grade coal and associated coal fires. Before it can be exploited, valuable coal reserves are destroyed in the sub-surface due to fire. The combined act of fire and subsidence has endangered the ...

Tapas Ranjan Martha; Arindam Guha; Kumranchat Vinod Kumar; M. V. V. Kamaraju; E. V. R. Raju

2010-04-01T23:59:59.000Z

124

EVALUATION OF DENSIFIED REFUSE DERIVED FUELS FOR USE IN PULVERIZED COAL-FIRED  

E-Print Network (OSTI)

EVALUATION OF DENSIFIED REFUSE DERIVED FUELS FOR USE IN PULVERIZED COAL-FIRED STEAM GENERATORS with coal. This paper discusses these successful tests and the feasibility of preparing a d-RDF which can be processed with coal using existing, unmodified coal handling equipment and fired in conventional pulverized

Columbia University

125

Design of a 6- by 6-foot coal-fired heater for a CCGT air heater  

Science Conference Proceedings (OSTI)

Coal-fired heaters for closed-cycle gas turbine have been designed and tested. One of the heater concepts employs the atmospheric pressure fluidized bed coal combustion process. The paper describes a research-oriented bed for the research program. Details are described and discussed of such heaters for cogeneration applications. 2 refs.

Russell, L.H.; Campbell, J. Jr.

1982-01-01T23:59:59.000Z

126

Combined Heat and Power: Coal-Fired Air Turbine (CAT)-Cycle Plant  

DOE Green Energy (OSTI)

By combining an integrated system with a gas turbine, coal-fired air turbine cycle technology can produce energy at an efficiency rate of over 40%, with capital and operating costs below those of competing conventional systems. Read this fact sheet to discover the additional benefits of this exciting new technology.

Recca, L.

1999-01-29T23:59:59.000Z

127

New Environmental Friendly Evaluation Criterion for Coal-Fired Power Plant Comprehensive Performance  

Science Conference Proceedings (OSTI)

This paper proposes a new environmental friendly evaluation criterion to assess the comprehensive performance of coal-fired power plant. The new evaluation criterion, which is called the comprehensive Index of Energy, Resources and Environment (IERE), ... Keywords: power plant, evaluation criterion, environmental friendly, comperhensive performance

Gang Xu; Shiyuan Lu; Yongping Yang; Liqiang Duan; Ji Li; Le Li; Xiaona Song

2010-06-01T23:59:59.000Z

128

The Carbon Emission Analysis System Design of Coal-Fired Unit  

Science Conference Proceedings (OSTI)

Carbon dioxide is the main cause of global warming, that emission has been the world's attention. and the power industry is an important source of carbon dioxide emissions, this paper try to design the system of power plants for carbon emissions coal-fired ... Keywords: Analysis system, Carbon emissions, Energy saving

Han Jieping; Zhang Chengzhen

2011-08-01T23:59:59.000Z

129

Corrosion and degradation of ceramic particulate filters in direct coal-fired turbine applications  

SciTech Connect

High-temperature ceramic filters show considerable promise for efficient particulate removal from coal combustion systems. Advanced coal utilization processes such as direct coal-fired turbines require particulate-free gas for successful operation. This paper describes the various ceramic particulate filters under development and reviews the degradation mechanisms expected when operated in coal combustion systems.

Sawyer, J. (Acurex Corp., Mountain View, CA (US)); Vass, R.J.; Brown, N.R.; Brown, J.J. (Center for Advanced Ceramic Materials, CIT TDC, Virginai Polytechnic Inst. and State Univ., Blacksburg, VA (US))

1991-10-01T23:59:59.000Z

130

Edward Bruce Held | National Nuclear Security Administration  

National Nuclear Security Administration (NNSA)

Edward Bruce Held | National Nuclear Security Administration Edward Bruce Held | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > About Us > Our Leadership > Edward Bruce Held Edward Bruce Held Acting Administrator and Acting Undersecretary for Nuclear Security Bruce Held Bruce Held is the Acting Undersecretary for Nuclear Security with

131

Multi-Pathway Human Health and Ecological Risk Assessment for a Model Coal-Fired Power Plant  

Science Conference Proceedings (OSTI)

This report describes a multimedia human health and ecosystem risk study of a model coal-fired power plant in a model setting, using data on an actual power plant transposed to a lakeside setting in the same state.

2011-10-01T23:59:59.000Z

132

Integration and operation of post-combustion capture system on coal-fired power generation: load following and peak power  

E-Print Network (OSTI)

Coal-fired power plants with post combustion capture and sequestration (CCS) systems have a variety of challenges to integrate the steam generation, air quality control, cooling water systems and steam turbine with the ...

Brasington, Robert David, S.M. Massachusetts Institute of Technology

2012-01-01T23:59:59.000Z

133

Feasibility Study for Bioethanol Co-Location with a Coal Fired Power Plant: 29 November 2001--28 July 2002  

Science Conference Proceedings (OSTI)

This study looks at the feasibility of co-locating 30, 50, and 70 million gallon per year bioethanol facilities with coal fired power plants in Indiana and Nebraska. Corn stover is the feedstock for ethanol production in both cases.

Not Available

2002-12-01T23:59:59.000Z

134

NNSA Acting Administrator Bruce Held holds all hands meeting...  

NLE Websites -- All DOE Office Websites (Extended Search)

Media Room > Photo Gallery > NNSA Acting Administrator Bruce Held holds all ... NNSA Acting Administrator Bruce Held holds all hands meeting NNSANews posted a photo: NNSA Acting...

135

Mercury Reduction in Coal-Fired Power Plants: DOE's R&D Program  

NLE Websites -- All DOE Office Websites (Extended Search)

Reduction in Coal-Fired Power Reduction in Coal-Fired Power Plants: DOE's R&D Program ARIPPA Technical Symposium August 21, 2002 State College, PA Thomas J. Feeley, III, Product Manager Innovations for Existing Plants ARIPPA_TJF082102 Presentation Outline * About NETL * IEP Program * Hg Background * Hg Control R&D * Q&As ARIPPA_TJF082102 About NETL ARIPPA_TJF082102 * One of DOE's 17 national labs * Government owned / operated * Sites in: - Pennsylvania - West Virginia - Oklahoma - Alaska * More than 1,100 federal and support contractor employees National Energy Technology Laboratory ARIPPA_TJF082102 Electric Power Using Coal Clean Liquid Fuels Natural Gas Coal Production Environmental Control V21 Next Generation Carbon Sequestration Exploration & Production Refining & Delivery Alternative Fuels Exploration &

136

NETL: News Release - Novel Coal-Fired Heating System Proves Successful at  

NLE Websites -- All DOE Office Websites (Extended Search)

December 20, 2005 December 20, 2005 Novel Coal-Fired Heating System Proves Successful at Ohio Greenhouse Cost Savings and State EPA Standards Achieved in First Commercial Demonstration WASHINGTON, DC - Using a Department of Energy - funded coal-fired technology, a greenhouse in northeast Ohio is saving more than $1,000 a day in heating costs. The efficient fluidized-bed combustion unit provides an alternative to natural gas systems and, using locally available coal and limestone, surpasses state EPA standards for sulfur capture and stack emissions. "The promise of the unit lies in its novel design," said Donald Bonk, a senior technical advisor for the National Energy Technology Laboratory (NETL), which manages the project for the Energy Department. "The fluidized-bed combustion system features flue-gas recirculation, replacing conventional, more expensive boiler tubes. By recycling the flue gas, the system better controls internal temperatures to burn fuel, reducing the formation of pollutants."

137

Potential of hybrid geothermal/coal fired power plants in Arizona  

DOE Green Energy (OSTI)

The City of Burbank and the Ralph M. Parsons Company studies showed several advantages for hybrid geothermal/coal fired power plants, as follows: (1) the estimated cost of producing electricity in hybrid plant is about 18.3 mills/kWh, compared to 19.3 mills/kWh in an all-coal fired power plant; (2) the coal requirements for a given plant can be reduced about 12 to 17%; and (3) the geothermal brines can be used for power plant cooling water, and in some cases, as boiler feedwater. The pertinent results of the City of Burbank studies are summarized and applied to the geothermal and coal resources of Arizona for possible future utilization.

White, D.H.; Goldstone, L.A.

1982-08-01T23:59:59.000Z

138

Emissions, Monitoring, and Control of Mercury from Subbituminous Coal-Fired Power Plants - Phase II  

SciTech Connect

Western Research Institute (WRI), in conjunction with Western Farmers Electric Cooperative (WFEC), has teamed with Clean Air Engineering of Pittsburgh PA to conduct a mercury monitoring program at the WEFC Hugo plant in Oklahoma. Sponsored by US Department of Energy Cooperative Agreement DE-FC-26-98FT40323, the program included the following members of the Subbituminous Energy Coalition (SEC) as co-sponsors: Missouri Basin Power Project; DTE Energy; Entergy; Grand River Dam Authority; and Nebraska Public Power District. This research effort had five objectives: (1) determine the mass balance of mercury for subbituminous coal-fired power plant; (2) assess the distribution of mercury species in the flue gas (3) perform a comparison of three different Hg test methods; (4) investigate the long-term (six months) mercury variability at a subbituminous coal-fired power plant; and (5) assess operation and maintenance of the Method 324 and Horiba CEMS utilizing plant personnel.

Alan Bland; Jesse Newcomer; Allen Kephart; Volker Schmidt; Gerald Butcher

2008-10-31T23:59:59.000Z

139

Tracking new coal-fired power plants: coal's resurgence in electric power generation  

Science Conference Proceedings (OSTI)

This information package is intended to provide an overview of 'Coal's resurgence in electric power generation' by examining proposed new coal-fired power plants that are under consideration in the USA. The results contained in this package are derived from information that is available from various tracking organizations and news groups. Although comprehensive, this information is not intended to represent every possible plant under consideration but is intended to illustrate the large potential that exists for new coal-fired power plants. It should be noted that many of the proposed plants are likely not to be built. For example, out of a total portfolio (gas, coal, etc.) of 500 GW of newly planned power plant capacity announced in 2001, 91 GW have been already been scrapped or delayed. 25 refs.

NONE

2007-05-01T23:59:59.000Z

140

European legislation in the United Kingdom: a threat to coal-fired power station product utilization?  

SciTech Connect

The author considers that the European Union has not taken the approach adopted in the USA where environmental regulators are keen to promote the use of coal-fired power station ash by-product and recycled materials. The United Kingdom has seen, with some dismay, the effects EU legislation is having on the ash industry. This article outlines only some of the problems being tackled. The Waste Framework Directive is difficult to interpret and fails to define critical aspects of the problem. This directive is discussed at some length in the article. A total of nine directives effect the operation of coal-fired power plant. Many are imprecise and open to interpretation and cause a deal of frustration, delays and confusion to the ash supplier and contractor. This is causing markets to suffer.

Sear, K.A. [Quality Ash Association (United Kingdom)

2006-07-01T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Jupiter Oxy-combustion and Integrated Pollutant Removal for the Existing Coal Fired Power Generation Fleet  

NLE Websites -- All DOE Office Websites (Extended Search)

Jupiter Oxy-combustion and Integrated Jupiter Oxy-combustion and Integrated Pollutant Removal for the Existing Coal Fired Power Generation Fleet Background The mission of the U.S. Department of Energy/National Energy Technology Laboratory (DOE/NETL) Existing Plants, Emissions & Capture (EPEC) Research & Development (R&D) Program is to develop innovative environmental control technologies to enable full use of the nation's vast coal reserves, while at the same time allowing the current fleet of

142

Options for reducing a coal-fired plant's carbon footprint, Part II  

Science Conference Proceedings (OSTI)

Part 1 of this article detailed and quantified the impacts of postcoming CO{sub 2} capture on a coal plant's net output and efficiency. Part II deals with four other CO{sub 2} reduction techniques: oxy-fuel combustion, using higher-temperature and higher-pressure boilers, cofiring biomass, and replacing some coal-fired capacity with renewable capacity. 4 figs., 3 tabs.

Zachary, J. [Bechtel Power Corp. (United States)

2008-07-15T23:59:59.000Z

143

Performance of composite coatings in a coal-fired boiler environment  

Science Conference Proceedings (OSTI)

Four samples of thermal spray coatings, each made from different core wire consumables by twin wire arc spray, were exposed for 18 months in a coal-fired boiler environment. The tests are described and the performance of each coating is evaluated. Results indicated that the four consumable wire alloys showed remarkable resistance to fly ash erosion and corrosion over the period of the test.

Nava, J.C. [ME Technical Services, Bridgeton, MO (United States)

2009-09-15T23:59:59.000Z

144

Application Guideline for Monitoring Ammonia with Tunable Diode Lasers on Coal-Fired Boilers  

Science Conference Proceedings (OSTI)

Continuous ammonia monitors for coal-fired applications have been under development dating back to the 1990s. One potential use for NH3 process monitors is in support of selective catalytic (SCR) and selective non-catalytic (SNCR) NOx reduction systems that have been employed for NOx control. The primary analyzers being used in the utility industry are in situ tunable diode laser-based systems (TDL). Monitor applications can cover a range of potential needs ...

2012-12-31T23:59:59.000Z

145

Slipstream Testing of a Membrane CO2 Capture Process for Existing Coal-Fired Power Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

Testing of a Membrane CO Testing of a Membrane CO 2 Capture Process for Existing Coal-Fired Power Plants Background The mission of the U.S. Department of Energy/National Energy Technology Laboratory (DOE/NETL) Existing Plants, Emissions & Capture (EPEC) Research & Development (R&D) Program is to develop innovative environmental control technologies to enable full use of the nation's vast coal reserves, while at the same time allowing the current fleet of

146

EPRI 2002 Workshop on Combustion-Based NOx Controls for Coal-Fired Boilers  

Science Conference Proceedings (OSTI)

The Workshop on Combustion-Based NOx Controls for Coal-Fired Boilers, formerly the Workshop on NOx Controls for Utility Boilers, was the sixth in a series sponsored by EPRI and offered attendees a comprehensive picture of recent developments and full-scale applications of control technologies for nitrogen oxides (NOx). The workshop took place on October 24-25, 2002, in Atlanta, Georgia.

2003-01-14T23:59:59.000Z

147

Atmospheric Deposition of Mercury, Trace Elements, and Major Ions Around a Coal-fired Power Plant  

Science Conference Proceedings (OSTI)

This report describes the results of a multiyear study to measure mercury (Hg), trace elements, and major ions in precipitation around Plant Crist, a four-unit coal-fired power plant in Pensacola, Florida. The main purpose of the study was to see if Hg emissions from Plant Crist could be detected and quantified in local wet deposition. Specifically, the study evaluated whether the significant reduction in Hg emissions that accompanied the installation of a wet flue gas desulfurization scrubber ...

2013-12-22T23:59:59.000Z

148

An Assessment of Alternative NOx Monitoring Technologies for Coal-Fired Boiler Applications  

Science Conference Proceedings (OSTI)

This report reviews the applicability of alternate measurement technologies to measure NOx in coal-fired boiler applications using optical techniques in general, and tunable diode laser spectroscopy in particular. Increasingly stringent regulations of NOx emission limits on this class of boilers make accurate, reliable, cost effective measurement techniques of growing importance. Existing commercial instrumentation used for CEMS applications, do not entirely satisfy industry requirements and needs for pr...

2005-12-12T23:59:59.000Z

149

Program on Technology Innovation: Modified Brayton Cycle for Use in Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

A modified closed Brayton cycle using supercritical carbon dioxide (SCO2) as the working fluid is being proposed for a number of power generation applications. The technology offers the prospect of increased plant efficiency and reduced plant cost. This report compares candidate closed Brayton cycle performance with advanced ultra-supercritical steam-Rankine cycle performance.BackgroundIncreasing the efficiency of coal-fired steam-electric power ...

2013-02-14T23:59:59.000Z

150

Guidance for Comanagement of Mill Rejects at Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

Traditionally, utilities have comanaged some or all of their low-volume wastes with their high-volume combustion by-products in disposal facilities. This report presents guidance on comanagement of coal combustion by-products and mill rejects containing pyrites at coal-fired power plants. The report specifically addresses the issue of environmental protection from leachates due to oxidation of pyrites under certain conditions. Included is a discussion of acid-base accounting and neutralization capacity o...

1999-06-22T23:59:59.000Z

151

Understanding Mercury Chemistry in Coal-Fired Boilers: Biennial Report December 2001 December 2003  

Science Conference Proceedings (OSTI)

This report describes progress on a research program cosponsored by Tennessee Valley Authority (TVA) and the U.S. Environmental Protection Agency (EPA). The overall objective of this program is to gain an understanding of the chemistry and kinetics of mercury speciation in post-furnace regions of coal-fired utility boilers, in order to enhance the oxidation of elemental mercury for subsequent capture by air pollution controls, such as electrostatic precipitators (ESPs), baghouses, and especially sulfur d...

2003-12-17T23:59:59.000Z

152

Program on Technology Innovation: Formation of Large Particle Ash in Coal-Fired Boilers  

Science Conference Proceedings (OSTI)

The objective of this project was to obtain a better understanding of the process that underlies the formation of large particle ash (LPA) in coal-fired boilers. As an approach, sample sets of coal, fireside ash deposits, and LPA were collected from selected boilers identified by the Electric Power Research Institute (EPRI) and were characterized using scanning electron microscopy (SEM) and x-ray microanalysis techniques. The coals were characterized to determine the abundance, size, and composition of t...

2010-02-08T23:59:59.000Z

153

Assessing Cancer Risk of Coal-Fired Power Plant Workers Exposed to PAHs  

Science Conference Proceedings (OSTI)

To study the relationship between the concentration of urinary 1-OH-Py, 3-OH-BaP and the degree as well as the pathways of human exposure to PAHs, we collected 24-hour air, dietary and urine samples of 60 oven workers in a coal-fired power plant of Central ... Keywords: biomarkers, medium-air and food, polycyclic aromatic hydrocarbons (PAHs), exposure assessment, cancer risk

Bin Li; Zhaolong Zhang; Haitao Fan; Cheng Zeng

2012-05-01T23:59:59.000Z

154

Optimum cycle parameters of coal fired closed cycle gas turbine in regenerative and combined cycle configurations  

Science Conference Proceedings (OSTI)

This paper presents the methodology developed for the estimation of thermodynamic performance and reports the optimum cycle parameters of coal fired CCGT in regenerative and combined cycle configurations using air, helium and carbon dioxide as working gases. A rigorous approach has been followed for the determination of the cycle efficiency by assuming the specific heat of working gases as a continuous function of temperature for accurate estimation of cycle parameters. 14 refs.

Rao, J.S.

1982-01-01T23:59:59.000Z

155

Multimedia Mercury Fate at Coal-Fired Power Plants Equipped With SCR and Wet FGD Controls  

Science Conference Proceedings (OSTI)

Given the current regulatory climate in the United States, a number of selective catalytic reduction (SCR) and flue gas desulfurization (FGD) systems will be installed at new and existing coal-fired power plants to remove nitrogen oxide (NOx), sulfur dioxide (SO2), and mercury. The multimedia fate of trace metal species, especially mercury, in SCR/wet FGD systems is not well understood. Understanding and quantifying the amount of mercury removed from the flue gas and distributed to the solid and aqueous ...

2008-03-19T23:59:59.000Z

156

Characterization of Toxicity of Coal-Fired Power Plant Effluents to Freshwater Mussels  

Science Conference Proceedings (OSTI)

Coal-fired power plant wastewater effluents contain metals and other materials that may harm aquatic life living in receiving streams adjacent to power plants. Characterization of the hazard associated with these wastewater effluents will inform plant operators such that they may alter processes in order to promote cleaner wastewater discharges. This interim report discusses efforts to culture healthy aquatic organisms to be used in toxicity bioassays. Culture and bioassay methods are refined and ready f...

2009-12-02T23:59:59.000Z

157

Characterization of Toxicity of Coal-Fired Power Plant Effluents to Freshwater Mussels  

Science Conference Proceedings (OSTI)

The Environmental Protection Agency (EPA) has voiced concerns about fluidized gas desulfuration (FGD-) influenced waste streams regarding compliance with water quality standards. The effects of these effluents on aquatic organisms need to be quantified to better characterize the risk to aquatic ecosystems. This interim report discusses results of effluent toxicity tests performed over the past year. Four separate shipments of effluents were received from three different coal-fired power plants. Resultin...

2010-11-23T23:59:59.000Z

158

Effect of the shutdown of a large coal-fired power plant on ambient mercury  

NLE Websites -- All DOE Office Websites (Extended Search)

Effect of the shutdown of a large coal-fired power plant on ambient mercury Effect of the shutdown of a large coal-fired power plant on ambient mercury species Title Effect of the shutdown of a large coal-fired power plant on ambient mercury species Publication Type Journal Article LBNL Report Number LBNL-6097E Year of Publication 2013 Authors Wang, Yungang, Jiaoyan Huang, Philip K. Hopke, Oliver V. Rattigan, David C. Chalupa, Mark J. Utell, and Thomas M. Holsen Journal Chemosphere Volume 92 Issue 4 Pagination 360-367 Date Published 07/2013 Abstract In the spring of 2008, a 260MWe coal-fired power plant (CFPP) located in Rochester, New York was closed over a 4 month period. Using a 2-years data record, the impacts of the shutdown of the CFPP on nearby ambient concentrations of three Hg species were quantified. The arithmetic average ambient concentrations of gaseous elemental mercury (GEM), gaseous oxidized mercury (GOM), and particulate mercury (PBM) during December 2007-November 2009 were 1.6ng/m3, 5.1pg/m3, and 8.9pg/m3, respectively. The median concentrations of GEM, GOM, and PBM significantly decreased by 12%, 73%, and 50% after the CFPP closed (Mann-Whitney test, p<0.001). Positive Matrix Factorization (EPA PMF v4.1) identified six factors including O3-rich, traffic, gas phase oxidation, wood combustion, nucleation, and CFPP. When the CFPP was closed, median concentrations of GEM, GOM, and PBM apportioned to the CFPP factor significantly decreased by 25%, 74%, and 67%, respectively, compared to those measured when the CFPP was still in operation (Mann-Whitney test, p<0.001). Conditional probability function (CPF) analysis showed the greatest reduction in all three Hg species was associated with northwesterly winds pointing toward the CFPP. These changes were clearly attributable to the closure of the CFPP.

159

Parameters affecting nitrogen oxides in a Coal-Fired Flow Facility system  

DOE Green Energy (OSTI)

The unusually high temperature in the primary combustor of the Coal-Fired Magnetohydrodynamics (MHD) power generation system causes much higher nitrogen oxides (NO{sub x}) to be produced than in a conventional coal fired generation system. In order to lower the NO{sub x} concentration to an acceptable level, it is important to know how parameters of the MM power generation system affect the NO{sub x} concentration. This thesis investigates those effects in the Coal-Fired Flow Facility (CFFF) at the University of Tennessee Space Institute under the contract of US Department Of Energy (DOE). With thermodynamic and kinetic computer codes, the theoretical studies were carried out on the parameters of the CFFF system. The results gathered from the computer codes were analyzed and compared with the experimental data collected during the LMF5J test. The thermodynamic and kinetic codes together modeled the NO.{sub x} behavior with reasonable accuracy while some inconsistencies happened at the secondary combustor inlet.

Lu, Xiaoliang

1996-03-01T23:59:59.000Z

160

Development and design of an advanced pulverized coal-fired system  

SciTech Connect

Under the US Department of Energy (DOE) project `Engineering Development of Advanced Coal-Fired Low-Emission Boiler Systems` (LEBS) the ABB team developed the design of a 400 MWe advanced pulverized coal fired electric generating system. The work and the results are described in the paper. Early work included concept development and evaluation of several subsystems for controlling the emission of SO{sub 2}, NO{sub x}, particulates and for reducing wastes. Candidate technologies were then evaluated in various combinations as part of complete advanced supercritical power generation systems. One system was selected for the design of the advanced generating system. Pilot scale testing is now being conducted to support the design of subsystems. The design meets the overall objective of the LEBS Project by dramatically improving environmental performance of pulverized coal fired power plants without adversely impacting efficiency or the cost of electricity. Advanced technologies will be used to reduce NO{sub x}, SO{sub 2}, and particulate emissions to one-fifth to one-tenth of current NSPS limits. Air toxics will be in compliance, and wastes will be reduced and made more disposable. Net station (HHV) efficiency can be increased to 45 percent without increasing the cost of electricity.

Regan, J.W.; Borio, R.W.; Palkes, M. [ABB Power Plant Laboratories (United States); Mirolli, M.D. [ABB Combustion Engineering, Inc., Windsor, CT (United States); Wesnor, J.D. [ABB Environmental Systems, Birmingham, AL (United States); Bender, D.J. [Raytheon Engineers & Constructors, Inc. (United States)

1995-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Conceptual design of a coal-fired MHD retrofit. Final technical report  

SciTech Connect

Coal-fired magnetohydrodynamics (MHD) technology is ready for its next level of development - an integrated demonstration at a commercial scale. The development and testing of MHD has shown its potential to be the most efficient, least costly, and cleanest way to burn coal. Test results have verified a greater than 99% removal of sulphur with a potential for greater than 60% efficiency. This development and testing, primarily funded by the U.S. Department of Energy (DOE), has progressed through the completion of its proof-of-concept (POC) phase at the 50 MWt Component Development and Integration Facility (CDIF) and 28 MWt Coal Fired Flow Facility (CFFF), thereby, providing the basis for demonstration and further commercial development and application of the technology. The conceptual design of a retrofit coal-fired MHD generating plant was originally completed by the MHD Development Corporation (MDC) under this Contract, DE-AC22-87PC79669. Thereafter, this concept was updated and changed to a stand-alone MHD demonstration facility and submitted by MDC to DOE in response to the fifth round of solicitations for Clean Coal Technology. Although not selected, that activity represents the major interest in commercialization by the developing industry and the type of demonstration that would be eventually necessary. This report updates the original executive summary of the conceptual design by incorporating the results of the POC program as well as MDC`s proposed Billings MHD Demonstration Project (BMDP) and outlines the steps necessary for commercialization.

NONE

1994-06-01T23:59:59.000Z

162

A Review of Hazardous Chemical Species Associated with CO2 Capture from Coal-Fired Power Plants and Their Potential Fate in CO2 Geologic Storage  

E-Print Network (OSTI)

from combustion and gasification of coal an equilibriumHolysh, M. 2005. Coke Gasification: Advanced technology forfrom a Coal-Fired Gasification Plant. Final Report, December

Apps, J.A.

2006-01-01T23:59:59.000Z

163

A Low Cost and High Efficient Facility for Removal of $\\SO_{2}$ and $\\NO_{x}$ in the Flue Gas from Coal Fire Power Plant  

E-Print Network (OSTI)

A Low Cost and High Efficient Facility for Removal of $\\SO_{2}$ and $\\NO_{x}$ in the Flue Gas from Coal Fire Power Plant

Pei, Y J; Dong, X; Feng, G Y; Fu, S; Gao, H; Hong, Y; Li, G; Li, Y X; Shang, L; Sheng, L S; Tian, Y C; Wang, X Q; Wang, Y; Wei, W; Zhang, Y W; Zhou, H J

2001-01-01T23:59:59.000Z

164

Contract status report for MHD research and development and operation of the MHD Coal Fired Flow Facility for the month ending June 30, 1995  

DOE Green Energy (OSTI)

This report contains the operations schedule for the month of June 1995 at the University of Tennessee Space Institute`s Coal Fired MHD Flow Facility.

NONE

1995-08-01T23:59:59.000Z

165

Contract status report for MHD research and development and operation of the MHD coal fired flow facility for the month ending July 31, 1995  

DOE Green Energy (OSTI)

A milestone and status report is presented for the MHD coal-fired flow facility. A chart outlining the accrued project cost is also given.

NONE

1995-11-01T23:59:59.000Z

166

Contract status report for MHD research and development and operation of the MHD Coal Fired Flow Facility for the month ending May 31, 1995  

DOE Green Energy (OSTI)

This report contains the operations schedule for the month of May 1995 at the University of Tennessee Space Institute`s Coal Fired MHD Flow Facility.

NONE

1995-08-01T23:59:59.000Z

167

High-pressure coal-fired ceramic air heater for gas turbine applications. Technical quarterly progress report, May 1994--July 1994  

SciTech Connect

Progress is reported on the development of a coal-fired ceramic air heater for gas turbine applications. This report describes component development.

1996-02-01T23:59:59.000Z

168

Reducing water freshwater consumption at coal-fired power plants : approaches used outside the United States.  

Science Conference Proceedings (OSTI)

Coal-fired power plants consume huge quantities of water, and in some water-stressed areas, power plants compete with other users for limited supplies. Extensive use of coal to generate electricity is projected to continue for many years. Faced with increasing power demands and questionable future supplies, industries and governments are seeking ways to reduce freshwater consumption at coal-fired power plants. As the United States investigates various freshwater savings approaches (e.g., the use of alternative water sources), other countries are also researching and implementing approaches to address similar - and in many cases, more challenging - water supply and demand issues. Information about these non-U.S. approaches can be used to help direct near- and mid-term water-consumption research and development (R&D) activities in the United States. This report summarizes the research, development, and deployment (RD&D) status of several approaches used for reducing freshwater consumption by coal-fired power plants in other countries, many of which could be applied, or applied more aggressively, at coal-fired power plants in the United States. Information contained in this report is derived from literature and Internet searches, in some cases supplemented by communication with the researchers, authors, or equipment providers. Because there are few technical, peer-reviewed articles on this topic, much of the information in this report comes from the trade press and other non-peer-reviewed references. Reducing freshwater consumption at coal-fired power plants can occur directly or indirectly. Direct approaches are aimed specifically at reducing water consumption, and they include dry cooling, dry bottom ash handling, low-water-consuming emissions-control technologies, water metering and monitoring, reclaiming water from in-plant operations (e.g., recovery of cooling tower water for boiler makeup water, reclaiming water from flue gas desulfurization [FGD] systems), and desalination. Some of the direct approaches, such as dry air cooling, desalination, and recovery of cooling tower water for boiler makeup water, are costly and are deployed primarily in countries with severe water shortages, such as China, Australia, and South Africa. Table 1 shows drivers and approaches for reducing freshwater consumption in several countries outside the United States. Indirect approaches reduce water consumption while meeting other objectives, such as improving plant efficiency. Plants with higher efficiencies use less energy to produce electricity, and because the greater the energy production, the greater the cooling water needs, increased efficiency will help reduce water consumption. Approaches for improving efficiency (and for indirectly reducing water consumption) include increasing the operating steam parameters (temperature and pressure); using more efficient coal-fired technologies such as cogeneration, IGCC, and direct firing of gas turbines with coal; replacing or retrofitting existing inefficient plants to make them more efficient; installing high-performance monitoring and process controls; and coal drying. The motivations for increasing power plant efficiency outside the United States (and indirectly reducing water consumption) include the following: (1) countries that agreed to reduce carbon emissions (by ratifying the Kyoto protocol) find that one of the most effective ways to do so is to improve plant efficiency; (2) countries that import fuel (e.g., Japan) need highly efficient plants to compensate for higher coal costs; (3) countries with particularly large and growing energy demands, such as China and India, need large, efficient plants; (4) countries with large supplies of low-rank coals, such as Germany, need efficient processes to use such low-energy coals. Some countries have policies that encourage or mandate reduced water consumption - either directly or indirectly. For example, the European Union encourages increased efficiency through its cogeneration directive, which requires member states to assess their

Elcock, D. (Environmental Science Division)

2011-05-09T23:59:59.000Z

169

Reducing water freshwater consumption at coal-fired power plants : approaches used outside the United States.  

SciTech Connect

Coal-fired power plants consume huge quantities of water, and in some water-stressed areas, power plants compete with other users for limited supplies. Extensive use of coal to generate electricity is projected to continue for many years. Faced with increasing power demands and questionable future supplies, industries and governments are seeking ways to reduce freshwater consumption at coal-fired power plants. As the United States investigates various freshwater savings approaches (e.g., the use of alternative water sources), other countries are also researching and implementing approaches to address similar - and in many cases, more challenging - water supply and demand issues. Information about these non-U.S. approaches can be used to help direct near- and mid-term water-consumption research and development (R&D) activities in the United States. This report summarizes the research, development, and deployment (RD&D) status of several approaches used for reducing freshwater consumption by coal-fired power plants in other countries, many of which could be applied, or applied more aggressively, at coal-fired power plants in the United States. Information contained in this report is derived from literature and Internet searches, in some cases supplemented by communication with the researchers, authors, or equipment providers. Because there are few technical, peer-reviewed articles on this topic, much of the information in this report comes from the trade press and other non-peer-reviewed references. Reducing freshwater consumption at coal-fired power plants can occur directly or indirectly. Direct approaches are aimed specifically at reducing water consumption, and they include dry cooling, dry bottom ash handling, low-water-consuming emissions-control technologies, water metering and monitoring, reclaiming water from in-plant operations (e.g., recovery of cooling tower water for boiler makeup water, reclaiming water from flue gas desulfurization [FGD] systems), and desalination. Some of the direct approaches, such as dry air cooling, desalination, and recovery of cooling tower water for boiler makeup water, are costly and are deployed primarily in countries with severe water shortages, such as China, Australia, and South Africa. Table 1 shows drivers and approaches for reducing freshwater consumption in several countries outside the United States. Indirect approaches reduce water consumption while meeting other objectives, such as improving plant efficiency. Plants with higher efficiencies use less energy to produce electricity, and because the greater the energy production, the greater the cooling water needs, increased efficiency will help reduce water consumption. Approaches for improving efficiency (and for indirectly reducing water consumption) include increasing the operating steam parameters (temperature and pressure); using more efficient coal-fired technologies such as cogeneration, IGCC, and direct firing of gas turbines with coal; replacing or retrofitting existing inefficient plants to make them more efficient; installing high-performance monitoring and process controls; and coal drying. The motivations for increasing power plant efficiency outside the United States (and indirectly reducing water consumption) include the following: (1) countries that agreed to reduce carbon emissions (by ratifying the Kyoto protocol) find that one of the most effective ways to do so is to improve plant efficiency; (2) countries that import fuel (e.g., Japan) need highly efficient plants to compensate for higher coal costs; (3) countries with particularly large and growing energy demands, such as China and India, need large, efficient plants; (4) countries with large supplies of low-rank coals, such as Germany, need efficient processes to use such low-energy coals. Some countries have policies that encourage or mandate reduced water consumption - either directly or indirectly. For example, the European Union encourages increased efficiency through its cogeneration directive, which requires member states to assess their

Elcock, D. (Environmental Science Division)

2011-05-09T23:59:59.000Z

170

Residual carbon from pulverized coal fired boilers 1: Size distribution and combustion reactivity  

Science Conference Proceedings (OSTI)

The amount of residual, or unburned, carbon in fly ash is an important concern in the design and operation of pulverized coal-fired boilers. Char oxidation is the slowest step in the coal combustion process, and the rate at which this heterogeneous reaction-proceeds has an important effect on the degree of carbon burnout. There is an extensive literature on char combustion kinetics based on data in the early and intermediate stages of carbon conversion. A critical fundamental question is whether the small fraction of the fuel carbon that passes unreacted through a boiler is representative of the char during the main portion of the combustion process. This article addresses that question through a detailed characterization of eight carbon-containing fly ash samples acquired from commercial-scale combustion systems. The fly ash characterization included measurement-of joint carbon/size distribution and determination.of the combustion reactivity of the residual carbon. To minimize mineral matter interactions in the reactivity tests, the technique of incipient fluidization was developed for separation of carbon-rich extracts from the inorganic portion of the fly ash. Reactivity measurements were made at 1400--1800 K to represent conditions in pulverized coal fired boilers. Measurements were also made at 700--1100 K to. minimize transport effects and isolate the influence of char chemistry and microstructure. In both temperature regimes, the residual carbon extracts. were significantly less reactive than chars extracted from a laboratory-scale laminar flow reactor in the early-to-intermediate stages of combustion. It is concluded that the boiler environment deactivates chars, making high carbon burnout more difficult to achieve than is predicted by existing char combustion kinetic models that were developed from data on the laboratory chars. Finally, the results are used to discuss potential char deactivation mechanisms, both thermal and oxidative, in coal-fired boilers.

Hurt, R.H. [Sandia National Labs., Livermore, CA (United States); Gibbins, J.R. [Imperial Coll. of Science, Technology and Medicine, London (United Kingdom). Dept. of Mechanical Engineering

1994-08-01T23:59:59.000Z

171

Measurement and Modeling of SO3 Formation in Coal-Fired Power Boilers  

Science Conference Proceedings (OSTI)

Some fraction of the SO2 formed by oxidation of sulfur in a coal-fired boiler is further oxidized to SO3. As a rule of thumb, the SO3 concentration at the boiler's economizer exit is expected to be about 1% of the SO2 concentration; however, the actual value is strongly dependent on the fuel composition, boiler design, and the boiler operating conditions. Qualitatively, it is well accepted that iron in the convection section heat exchanger tubes and in the ash acts as a catalyst to promote oxidation of S...

2011-09-27T23:59:59.000Z

172

Characterization of Oxy-combustion Impacts in Existing Coal-fired Boilers  

NLE Websites -- All DOE Office Websites (Extended Search)

Characterization of Oxy-combustion Characterization of Oxy-combustion Impacts in Existing Coal-fired Boilers Background Technology and policy options are being investigated for mitigating CO 2 emissions. Electric power generation represents one of the largest CO 2 contributors in the United States and is expected to grow with fossil fuels continuing to be the dominant fuel source. Oxy-combustion is a developing technology that could become part of a national carbon capture effort to mitigate climate change. At a pulverized coal

173

Fuel supply system and method for coal-fired prime mover  

DOE Patents (OSTI)

A coal-fired gas turbine engine is provided with an on-site coal preparation and engine feeding arrangement. With this arrangement, relatively large dry particles of coal from an on-site coal supply are micro-pulverized and the resulting dry, micron-sized, coal particulates are conveyed by steam or air into the combustion chamber of the engine. Thermal energy introduced into the coal particulates during the micro-pulverizing step is substantially recovered since the so-heated coal particulates are fed directly from the micro-pulverizer into the combustion chamber.

Smith, William C. (Morgantown, WV); Paulson, Leland E. (Morgantown, WV)

1995-01-01T23:59:59.000Z

174

Effect of deposits on corrosion of materials exposed in the Coal-Fired Flow Facility  

DOE Green Energy (OSTI)

Candidate heat exchanger materials tested in the Low Mass Flow train at the Coal-Fired Flow Facility (CFFF) at Tullahoma, TN. were analyzed to evaluate their corrosion performance. Tube specimens obtained at each foot of the 14-ft-long Unbend tubes were analyzed for corrosion-scale morphologies, scale thicknesses, and internal penetration depths. Results developed on 1500- and 2000- h exposed specimens were correlated with exposure temperature. In addition, deposit materials collected at several locations in the CFFF were analyzed in detail to characterize the chemical and physical properties of the deposits and their influence on corrosion performance of tube materials.

Natesan, K.

1993-05-01T23:59:59.000Z

175

CO sub 2 emissions from coal-fired and solar electric power plants  

DOE Green Energy (OSTI)

This report presents estimates of the lifetime carbon dioxide emissions from coal-fired, photovoltaic, and solar thermal electric power plants in the United States. These CO{sub 2} estimates are based on a net energy analysis derived from both operational systems and detailed design studies. It appears that energy conservation measures and shifting from fossil to renewable energy sources have significant long-term potential to reduce carbon dioxide production caused by energy generation and thus mitigate global warming. The implications of these results for a national energy policy are discussed. 40 refs., 8 figs., 23 tabs.

Keith, F.; Norton, P.; Brown, D.

1990-05-01T23:59:59.000Z

176

Evaluation of electricity generation from underground coal fires and waste banks  

Science Conference Proceedings (OSTI)

A temperature response factors model of vertical thermal energy extraction boreholes is presented to evaluate electricity generation from underground coal fires and waste banks. Sensitivity and life-cycle cost analyses are conducted to assess the impact of system parameters on the production of 1 MW of electrical power using a theoretical binary-cycle power plant. Sensitivity analyses indicate that the average underground temperature has the greatest impact on the exiting fluid temperatures from the ground followed by fluid flow rate and ground thermal conductivity. System simulations show that a binary-cycle power plant may be economically feasible at ground temperatures as low as 190 {sup o}C.

Chiasson, A.D.; Yavuzturk, C.; Walrath, D.E. [Oregon Institute of Technology, Klamath Falls, OR (United States)

2007-06-15T23:59:59.000Z

177

Measurement and Modeling of SO3 Formation in Coal-Fired Power Boilers  

Science Conference Proceedings (OSTI)

This report presents results from the second full-scale test and associated modeling work conducted under EPRIs program on measurement and modeling of SO3 formation in coal-fired boilers. The objective of this program is to develop a fundamental understanding of the SO3 formation/depletion process with the hope that this understanding can suggest operational changes that minimize SO3 concentrations at the economizer outlet. The study focuses on SO3 formation up to the economizer outlet because SO3 forma...

2008-12-16T23:59:59.000Z

178

Construction program for a large superconducting MHD magnet system at the coal-fired flow facility  

DOE Green Energy (OSTI)

The Argonne National Laboratory has designed and is constructing a 6 T large aperture superconducting MHD magnet for use in the Coal-Fired Flow Facility (CFFF) at the University of Tennessee Space Institute (UTSI) at Tullahoma, Tennessee. The magnet system consists of the superconducting magnet, a magnet power supply, an integrated instrumentation for operation, control and protection, and a complete cryogenic facility including a CTI Model 2800 helium refrigerator/liquefier with two compressors, helium gas handling system and a 7500 liter liquid helium dewar. The complete system will be tested at Argonne, IL in 1981. The magnet design is reviewed, and the coil fabrication programs are described in detail.

Wang, S.T.; Genens, L.; Gonczy, J.; Ludwig, H.; Lieberg, M.; Kraft, E.; Gacek, D.; Huang, Y.C.; Chen, C.J.

1980-01-01T23:59:59.000Z

179

Flue Gas Conditioning to Reduce Particulate Emissions in Industrial Coal-Fired Boilers  

E-Print Network (OSTI)

Chemical technology has been used successfully to solve many of the operational and emissions problems that result from burning coal. This paper describes the use of blended chemical flue gas conditioners to significantly reduce particulate emissions in coal-fired industrial boilers. In many cases, these chemical conditioning agents have increased the efficiency of electrostatic precipitators and mechanical collectors by more than fifty percent. The effectiveness of this technology has been demonstrated on units generating 50,000 to 200,000 lbs./hr. steam. Results achieved at various industrial plants under actual operating conditions are presented.

Miller, B.; Keon, E.

1980-01-01T23:59:59.000Z

180

CO2 Capture Options for an Existing Coal Fired Power Plant: O2/CO2 Recycle Combustion vs. Amine Scrubbing  

NLE Websites -- All DOE Office Websites (Extended Search)

OPTIONS FOR AN EXISTING COAL FIRED POWER PLANT: OPTIONS FOR AN EXISTING COAL FIRED POWER PLANT: O 2 /CO 2 RECYCLE COMBUSTION vs. AMINE SCRUBBING D. J. Singh (djsingh@uwaterloo.ca; +001-519-496-2064) E. Croiset 1 (ecroiset@uwaterloo.ca;+001-519-888-4567x6472) P.L. Douglas (pdouglas@uwaterloo.ca; +001-519-888-4567x2913) Department of Chemical Engineering, University of Waterloo, Waterloo, Ontario, Canada, N2L 3G1 M.A. Douglas (madougla@nrcan.gc.ca; +001-613 996-2761) CANMET Energy Technology Centre, Natural Resources Canada, 1 Haanel Dr., Nepean, Ontario, Canada, K1A 1M1 Abstract The existing fleet of modern pulverized coal fired power plants represents an opportunity to achieve significant greenhouse gas (GHG) emissions in the coming years providing efficient and economical CO 2 capture technologies are available for retrofit.

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

NUCLEAR-CONVENTIONAL POWER PLANT COST STUDY CONVENTIONAL COAL FIRED POWER PLANTS, 25,000 KW TO 325,000 KW, FOR ARGONNE NATIONAL LABORATORY, LEMONT, ILLINOIS  

SciTech Connect

In order to establish a basis for comparing the estimated cost of nuclear power plant designs, a set of general and detailed design considerations for conventional coal-fired power plants was established. Five preliminary designs of conventional coal-fired power plants ranging in size from 25to 325 mw were selected, and cost estimates were prepared. ( A.C.)

Chittenden, W.A.

1959-03-01T23:59:59.000Z

182

Technical progress report for the Magnetohydrodynamics Coal-Fired Flow Facility. January 1, 1993--March 31, 1993  

DOE Green Energy (OSTI)

Progress is reported in developing technology for steam bottoming cycle of the coal-fired MHD Steam Combined Cycle Power Plant. During this period, no testing was scheduled in the DOE Coal-Fired Flow Facility. The report covers facilities modification and maintenance in preparation for a 225 hour POC test that is scheduled for early next quarter. The modifications to the dry ESP to replace the electrodes with smaller diameter wires is discussed. Continued work on the rotary vacuum filter, which is designed to separate the more soluble potassium carbonate from the potassium sulfate and fly ash, is reported. Environmental activities for the quarter are summarized.

Not Available

1993-07-01T23:59:59.000Z

183

Life assessment and emissions monitoring of Indian coal-fired power plants. Final report  

Science Conference Proceedings (OSTI)

At the request of the Pittsburgh Energy Technology Center (PETC) of the United States Department of Energy (USDOE), the traveler, along with Dr. R. P. Krishnan, Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee spent three weeks in India planning and performing emissions monitoring at the coal-fired Vijayawada Thermal Power Station (VTPS). The coordination for the Indian participants was provided by BHEL, Trichy and CPRI, Bangalore. The trip was sponsored by the PETC under the United States Agency for International Development (USAID)/Government of India (GOI)P Alternate Energy Resources Development (AERD) Project. The AERD Project is managed by PETC, and ORNL is providing the technical coordination and support for four coal projects that are being implemented with BHEL, Trichy. The traveler, after briefing the USAID mission in New Delhi visited BHEL, Trichy and CPRI, Bangalore to coordinate and plan the emissions test program. The site selection was made by BHEL, CPRI, TVA, and PETC. Monitoring was performed for 4 days on one of the 4 existing 210 MW coal-fired boilers at the VTPS, 400 km north of Madras, India.

Not Available

1992-07-01T23:59:59.000Z

184

Life assessment and emissions monitoring of Indian coal-fired power plants  

Science Conference Proceedings (OSTI)

At the request of the Pittsburgh Energy Technology Center (PETC) of the United States Department of Energy (USDOE), the traveler, along with Dr. R. P. Krishnan, Oak Ridge National Laboratory (ORNL), Oak Ridge, Tennessee spent three weeks in India planning and performing emissions monitoring at the coal-fired Vijayawada Thermal Power Station (VTPS). The coordination for the Indian participants was provided by BHEL, Trichy and CPRI, Bangalore. The trip was sponsored by the PETC under the United States Agency for International Development (USAID)/Government of India (GOI)P Alternate Energy Resources Development (AERD) Project. The AERD Project is managed by PETC, and ORNL is providing the technical coordination and support for four coal projects that are being implemented with BHEL, Trichy. The traveler, after briefing the USAID mission in New Delhi visited BHEL, Trichy and CPRI, Bangalore to coordinate and plan the emissions test program. The site selection was made by BHEL, CPRI, TVA, and PETC. Monitoring was performed for 4 days on one of the 4 existing 210 MW coal-fired boilers at the VTPS, 400 km north of Madras, India.

Not Available

1992-07-01T23:59:59.000Z

185

Economic analysis of coal-fired cogeneration plants for Air Force bases  

SciTech Connect

The Defense Appropriations Act of 1986 requires the Department of Defense to use an additional 1,600,000 tons/year of coal at their US facilities by 1995 and also states that the most economical fuel should be used at each facility. In a previous study of Air Force heating plants burning gas or oil, Oak Ridge National Laboratory found that only a small fraction of this target 1,600,000 tons/year could be achieved by converting the plants where coal is economically viable. To identify projects that would use greater amounts of coal, the economic benefits of installing coal-fired cogeneration plants at 7 candidate Air Force bases were examined in this study. A life-cycle cost analysis was performed that included two types of financing (Air Force and private) and three levels of energy escalation for a total of six economic scenarios. Hill, McGuire, and Plattsburgh Air Force Bases were identified as the facilities with the best potential for coal-fired cogeneration, but the actual cost savings will depend strongly on how the projects are financed and to a lesser extent on future energy escalation rates. 10 refs., 11 figs., 27 tabs.

Holcomb, R.S.; Griffin, F.P.

1990-10-01T23:59:59.000Z

186

A. Kusiak and A. Burns, Mining Temporal Data: A Coal-Fired Boiler Case Study, Proceedings of International Conference, KES 2005, Melbourne, Australia, September 14-16, 2005, in R.  

E-Print Network (OSTI)

A. Kusiak and A. Burns, Mining Temporal Data: A Coal-Fired Boiler Case Study, Proceedings of the 9 3683, Springer, Heidelberg, Germany, 2005, pp. 953-958. Mining Temporal Data: A Coal-Fired Boiler Case. This paper presents an approach to control pluggage of a coal-fired boiler. The proposed approach involves

Kusiak, Andrew

187

Emissions, Monitoring and Control of Mercury from Subbituminous Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

The Subbituminous Energy Coalition (SEC) identified a need to re-test stack gas emissions from power plants that burn subbituminous coal relative to compliance with the EPA mercury control regulations for coal-fired plants. In addition, the SEC has also identified the specialized monitoring needs associated with mercury continuous emissions monitors (CEM). The overall objectives of the program were to develop and demonstrate solutions for the unique emission characteristics found when burning subbituminous coals. The program was executed in two phases; Phase I of the project covered mercury emission testing programs at ten subbituminous coal-fired plants. Phase II compared the performance of continuous emission monitors for mercury at subbituminous coal-fired power plants and is reported separately. Western Research Institute and a number of SEC members have partnered with Eta Energy and Air Pollution Testing to assess the Phase I objective. Results of the mercury (Hg) source sampling at ten power plants burning subbituminous coal concluded Hg emissions measurements from Powder River Basin (PBR) coal-fired units showed large variations during both ICR and SEC testing. Mercury captures across the Air Pollution Control Devices (APCDs) present much more reliable numbers (i.e., the mercury captures across the APCDs are positive numbers as one would expect compared to negative removal across the APCDs for the ICR data). Three of the seven units tested in the SEC study had previously shown negative removals in the ICR testing. The average emission rate is 6.08 lb/TBtu for seven ICR units compared to 5.18 lb/TBtu for ten units in the SEC testing. Out of the ten (10) SEC units, Nelson Dewey Unit 1, burned a subbituminous coal and petcoke blend thus lowering the total emission rate by generating less elemental mercury. The major difference between the ICR and SEC data is in the APCD performance and the mercury closure around the APCD. The average mercury removal values across the APCDs are 2.1% and 39.4% with standard deviations (STDs) of 1990 and 75%, respectively for the ICR and SEC tests. This clearly demonstrates that variability is an issue irrespective of using 'similar' fuels at the plants and the same source sampling team measuring the species. The study also concluded that elemental mercury is the main Hg specie that needs to be controlled. 2004 technologies such as activated carbon injection (ACI) may capture up to 60% with double digit lb/MMacf addition of sorbent. PRB coal-fired units have an Hg input of 7-15 lb/TBtu; hence, these units must operate at over 60% mercury efficiency in order to bring the emission level below 5.8 lb/TBtu. This was non-achievable with the best technology available as of 2004. Other key findings include: (1) Conventional particulate collectors, such as Cold-side Electro-Static Precipitators (CESPs), Hot-side Electro-Static Precipitator (HESP), and Fabric Filter (FF) remove nearly all of the particulate bound mercury; (2) CESPs perform better highlighting the flue gas temperature effect on the mercury removal. Impact of speciation with flue gas cooling is apparent; (3) SDA's do not help in enhancing adsorption of mercury vapor species; and (4) Due to consistently low chlorine values in fuels, it was not possible to analyze the impact of chlorine. In summary, it is difficult to predict the speciation at two plants that burn the same fuel. Non-fuel issues, such as flue gas cooling, impact the speciation and consequently mercury capture potential.

Alan Bland; Kumar Sellakumar; Craig Cormylo

2007-08-01T23:59:59.000Z

188

ECONOMICS AND FEASIBILITY OF RANKINE CYCLE IMPROVEMENTS FOR COAL FIRED POWER PLANTS  

SciTech Connect

ALSTOM Power Inc.'s Power Plant Laboratories (ALSTOM) has teamed with the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL), American Electric Company (AEP) and Parsons Energy and Chemical Group to conduct a comprehensive study evaluating coal fired steam power plants, known as Rankine Cycles, equipped with three different combustion systems: Pulverized Coal (PC), Circulating Fluidized Bed (CFB), and Circulating Moving Bed (CMB{trademark}). Five steam cycles utilizing a wide range of steam conditions were used with these combustion systems. The motivation for this study was to establish through engineering analysis, the most cost-effective performance potential available through improvement in the Rankine Cycle steam conditions and combustion systems while at the same time ensuring that the most stringent emission performance based on CURC (Coal Utilization Research Council) 2010 targets are met: > 98% sulfur removal; < 0.05 lbm/MM-Btu NO{sub x}; < 0.01 lbm/MM-Btu Particulate Matter; and > 90% Hg removal. The final report discusses the results of a coal fired steam power plant project, which is comprised of two parts. The main part of the study is the analysis of ten (10) Greenfield steam power plants employing three different coal combustion technologies: Pulverized Coal (PC), Circulating Fluidized Bed (CFB), and Circulating Moving Bed (CMB{trademark}) integrated with five different steam cycles. The study explores the technical feasibility, thermal performance, environmental performance, and economic viability of ten power plants that could be deployed currently, in the near, intermediate, and long-term time frame. For the five steam cycles, main steam temperatures vary from 1,000 F to 1,292 F and pressures from 2,400 psi to 5,075 psi. Reheat steam temperatures vary from 1,000 F to 1,328 F. The number of feedwater heaters varies from 7 to 9 and the associated feedwater temperature varies from 500 F to 626 F. The main part of the study therefore determines the steam cycle parameters and combustion technology that would yield the lowest cost of electricity (COE) for the next generation of coal-fired steam power plants. The second part of the study (Repowering) explores the means of upgrading the efficiency and output of an older existing coal fired steam power plant. There are currently more than 1,400 coal-fired units in operation in the United States generating about 54 percent of the electricity consumed. Many of these are modern units are clean and efficient. Additionally, there are many older units in excellent condition and still in service that could benefit from this repowering technology. The study evaluates the technical feasibility, thermal performance, and economic viability of this repowering concept.

Richard E. Waryasz; Gregory N. Liljedahl

2004-09-08T23:59:59.000Z

189

ECONOMICS AND FEASIBILITY OF RANKINE CYCLE IMPROVEMENTS FOR COAL FIRED POWER PLANTS  

SciTech Connect

ALSTOM Power Inc.'s Power Plant Laboratories (ALSTOM) has teamed with the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL), American Electric Company (AEP) and Parsons Energy and Chemical Group to conduct a comprehensive study evaluating coal fired steam power plants, known as Rankine Cycles, equipped with three different combustion systems: Pulverized Coal (PC), Circulating Fluidized Bed (CFB), and Circulating Moving Bed (CMB{trademark}). Five steam cycles utilizing a wide range of steam conditions were used with these combustion systems. The motivation for this study was to establish through engineering analysis, the most cost-effective performance potential available through improvement in the Rankine Cycle steam conditions and combustion systems while at the same time ensuring that the most stringent emission performance based on CURC (Coal Utilization Research Council) 2010 targets are met: > 98% sulfur removal; < 0.05 lbm/MM-Btu NO{sub x}; < 0.01 lbm/MM-Btu Particulate Matter; and > 90% Hg removal. The final report discusses the results of a coal fired steam power plant project, which is comprised of two parts. The main part of the study is the analysis of ten (10) Greenfield steam power plants employing three different coal combustion technologies: Pulverized Coal (PC), Circulating Fluidized Bed (CFB), and Circulating Moving Bed (CMB{trademark}) integrated with five different steam cycles. The study explores the technical feasibility, thermal performance, environmental performance, and economic viability of ten power plants that could be deployed currently, in the near, intermediate, and long-term time frame. For the five steam cycles, main steam temperatures vary from 1,000 F to 1,292 F and pressures from 2,400 psi to 5,075 psi. Reheat steam temperatures vary from 1,000 F to 1,328 F. The number of feedwater heaters varies from 7 to 9 and the associated feedwater temperature varies from 500 F to 626 F. The main part of the study therefore determines the steam cycle parameters and combustion technology that would yield the lowest cost of electricity (COE) for the next generation of coal-fired steam power plants. The second part of the study (Repowering) explores the means of upgrading the efficiency and output of an older existing coal fired steam power plant. There are currently more than 1,400 coal-fired units in operation in the United States generating about 54 percent of the electricity consumed. Many of these are modern units are clean and efficient. Additionally, there are many older units in excellent condition and still in service that could benefit from this repowering technology. The study evaluates the technical feasibility, thermal performance, and economic viability of this repowering concept.

Richard E. Waryasz; Gregory N. Liljedahl

2004-09-08T23:59:59.000Z

190

Potential nanotechnology applications for reducing freshwater consumption at coal fired power plants : an early view.  

DOE Green Energy (OSTI)

This report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Existing Plants Research Program, which has an energy-water research effort that focuses on water use at power plants. This study complements the overall research effort of the Existing Plants Research Program by evaluating water issues that could impact power plants. A growing challenge to the economic production of electricity from coal-fired power plants is the demand for freshwater, particularly in light of the projected trends for increasing demands and decreasing supplies of freshwater. Nanotechnology uses the unique chemical, physical, and biological properties that are associated with materials at the nanoscale to create and use materials, devices, and systems with new functions and properties. It is possible that nanotechnology may open the door to a variety of potentially interesting ways to reduce freshwater consumption at power plants. This report provides an overview of how applications of nanotechnology could potentially help reduce freshwater use at coal-fired power plants. It was developed by (1) identifying areas within a coal-fired power plant's operations where freshwater use occurs and could possibly be reduced, (2) conducting a literature review to identify potential applications of nanotechnology for facilitating such reductions, and (3) collecting additional information on potential applications from researchers and companies to clarify or expand on information obtained from the literature. Opportunities, areas, and processes for reducing freshwater use in coal-fired power plants considered in this report include the use of nontraditional waters in process and cooling water systems, carbon capture alternatives, more efficient processes for removing sulfur dioxide and nitrogen oxides, coolants that have higher thermal conductivities than water alone, energy storage options, and a variety of plant inefficiencies, which, if improved, would reduce energy use and concomitant water consumption. These inefficiencies include air heater inefficiencies, boiler corrosion, low operating temperatures, fuel inefficiencies, and older components that are subject to strain and failure. A variety of nanotechnology applications that could potentially be used to reduce the amount of freshwater consumed - either directly or indirectly - by these areas and activities was identified. These applications include membranes that use nanotechnology or contain nanomaterials for improved water purification and carbon capture; nano-based coatings and lubricants to insulate and reduce heat loss, inhibit corrosion, and improve fuel efficiency; nano-based catalysts and enzymes that improve fuel efficiency and improve sulfur removal efficiency; nanomaterials that can withstand high temperatures; nanofluids that have better heat transfer characteristics than water; nanosensors that can help identify strain and impact damage, detect and monitor water quality parameters, and measure mercury in flue gas; and batteries and capacitors that use nanotechnology to enable utility-scale storage. Most of these potential applications are in the research stage, and few have been deployed at coal-fired power plants. Moving from research to deployment in today's economic environment will be facilitated with federal support. Additional support for research development and deployment (RD&D) for some subset of these applications could lead to reductions in water consumption and could provide lessons learned that could be applied to future efforts. To take advantage of this situation, it is recommended that NETL pursue funding for further research, development, or deployment for one or more of the potential applications identified in this report.

Elcock, D. (Environmental Science Division)

2010-09-17T23:59:59.000Z

191

MERCURY EMISSIONS FROM COAL FIRED POWER PLANTS LOCAL IMPACTS ON HUMAN HEALTH RISK.  

SciTech Connect

A thorough quantitative understanding of the processes of mercury emissions, deposition, and translocation through the food chain is currently not available. Complex atmospheric chemistry and dispersion models are required to predict concentration and deposition contributions, and aquatic process models are required to predict effects on fish. However, there are uncertainties in all of these predictions. Therefore, the most reliable method of understanding impacts of coal-fired power plants on Hg deposition is from empirical data. A review of the literature on mercury deposition around sources including coal-fired power plants found studies covering local mercury concentrations in soil, vegetation, and animals (fish and cows). There is strong evidence of enhanced local deposition within 3 km of the chlor-alkali plants, with elevated soil concentrations and estimated deposition rates of 10 times background. For coal-fired power plants, the data show that atmospheric deposition of Hg may be slightly enhanced. On the scale of a few km, modeling suggests that wet deposition may be increased by a factor of two or three over background. The measured data suggest lower increases of 15% or less. The effects of coal-fired plants seem to be less than 10% of total deposition on a national scale, based on emissions and global modeling. The following summarizes our findings from published reports on the impacts of local deposition. In terms of excesses over background the following increments have been observed within a few km of the plant: (1) local soil concentration Hg increments of 30%-60%, (2) sediment increments of 18-30%, (3) wet deposition increments of 11-12%, and (4) fish Hg increments of about 5-6%, based on an empirical finding that fish concentrations are proportional to the square root of deposition. Important uncertainties include possible reductions of RGM to Hg{sub 0} in power plant plumes and the role of water chemistry in the relationship between Hg deposition and fish content. Soil and vegetation sampling programs were performed around two mid-size coal fired power plants. The objectives were to determine if local mercury hot-spots exist, to determine if they could be attributed to deposition of coal-fired power plant emissions, and to determine if they correlated with model predictions. These programs found the following: (1) At both sites, there was no correlation between modeled mercury deposition and either soil concentrations or vegetation concentrations. At the Kincaid plant, there was excess soil Hg along heavily traveled roads. The spatial pattern of soil mercury concentrations did not match the pattern of vegetation Hg concentrations at either plant. (2) At both sites, the subsurface (5-10 cm) samples the Hg concentration correlated strongly with the surface samples (0-5 cm). Average subsurface sample concentrations were slightly less than the surface samples; however, the difference was not statistically significant. (3) An unequivocal definition of background Hg was not possible at either site. Using various assumed background soil mercury concentrations, the percentage of mercury deposited within 10 km of the plant ranged between 1.4 and 8.5% of the RGM emissions. Based on computer modeling, Hg deposition was primarily RGM with much lower deposition from elemental mercury. Estimates of the percentage of total Hg deposition ranged between 0.3 and 1.7%. These small percentages of deposition are consistent with the empirical findings of only minor perturbations in environmental levels, as opposed to ''hot spots'', near the plants. The major objective of this study was to determine if there was evidence for ''hot-spots'' of mercury deposition around coal-fired power plants. Although the term has been used extensively, it has never been defined. From a public health perspective, such a ''hot spot'' must be large enough to insure that it did not occur by chance, and it must affect water bodies large enough to support a population of subsistence fishers. The results of this study support the hypothesis that n

SULLIVAN, T.M.; BOWERMAN, B.; ADAMS, J.; LIPFERT, F.; MORRIS, S.M.; BANDO, A.; PENA, R.; BLAKE, R.

2005-12-01T23:59:59.000Z

192

Estimation of radiative properties and temperature distributions in coal-fired boiler furnaces by a portable image processing system  

Science Conference Proceedings (OSTI)

This paper presented an experimental investigation on the estimation of radiative properties and temperature distributions in a 670 t/h coal-fired boiler furnace by a portable imaging processing system. The portable system has been calibrated by a blackbody furnace. Flame temperatures and emissivities were measured by the portable system and equivalent blackbody temperatures were deduced. Comparing the equivalent blackbody temperatures measured by the portable system and the infrared pyrometer, the relative difference is less than 4%. The reconstructed pseudo-instantaneous 2-D temperature distributions in two cross-sections can disclose the combustion status inside the furnace. The measured radiative properties of particles in the furnace proved there is significant scattering in coal-fired boiler furnaces and it can provide useful information for the calculation of radiative heat transfer and numerical simulation of combustion in coal-fired boiler furnaces. The preliminary experimental results show this technology will be helpful for the combustion diagnosis in coal-fired boiler furnaces. (author)

Li, Wenhao; Lou, Chun; Sun, Yipeng; Zhou, Huaichun [State Key Laboratory of Coal Combustion, Huazhong University of Science and Technology, Wuhan, 430074 Hubei (China)

2011-02-15T23:59:59.000Z

193

Historical Costs of Coal-Fired Electricity and Implications for the Future James McNerney,a,b  

E-Print Network (OSTI)

density, thermal efficiency, plant construction cost, interest rate, and capacity factor. The dominant of the price of coal, coal transportation cost, coal energy density, thermal effi- ciency, plant construction in the United States, going back to the earliest coal-fired power plant in 1882 through 2006, rather than cross

194

Performance Analysis of Existing 600MW Coal-Fired Power Plant with Ammonia-Based CO2 Capture  

Science Conference Proceedings (OSTI)

This paper analyzes the techno-economic performance of 600 MW coal-fired power plant with and without ammonia-based CO2 capture process, based on the operating data of an existing power plant. The simulation and analysis, with fully consideration of ... Keywords: CO2 capture, aqueous ammonia, existing power plant, techno-economic performance

Gang Xu; Liqiang Duan; Mingde Zhao; Yongping Yang; Ji Li; Le Li; Haizhan Chen

2010-06-01T23:59:59.000Z

195

Consol Energy Summary Report: Evaluation of Mercury Emissions from Coal-Fired Facilities With SCR and FGD Systems  

Science Conference Proceedings (OSTI)

This project was a joint effort between EPRI, the U.S. Department of Energy, Consol Energy, and a number of electric utility companies who hosted the mercury field measurements. This report summarizes mercury measurements by the Consol Energy to characterize the impact of selective catalytic reduction (SCR) on mercury speciation and removal at ten (10) coal-fired power plants.

2006-09-20T23:59:59.000Z

196

Report on Geothermal Power Plant Cost and Comparative Cost of Geothermal and Coal Fired Steam Power Plants  

DOE Green Energy (OSTI)

This report is to be used by Utah Power and Light Company (UP and L) in making studies of geothermal power plants. The dollars per kilowatt comparison between a geothermal plant and a UP and L coal-fired plant is to be developed. Geothermal gathering system costs and return to owner are to be developed for information.

None

1977-07-01T23:59:59.000Z

197

Modeling NOx emissions from coal-fired utility boilers using support vector regression with ant colony optimization  

Science Conference Proceedings (OSTI)

Modeling NO"x emissions from coal fired utility boiler is critical to develop a predictive emissions monitoring system (PEMS) and to implement combustion optimization software package for low NO"x combustion. This paper presents an efficient NO"x emissions ... Keywords: Ant colony optimization, Artificial neural networks, Combustion modeling, NOx emissions modeling, Support vector regression

Hao Zhou; Jia Pei Zhao; Li Gang Zheng; Chun Lin Wang; Ke Fa Cen

2012-02-01T23:59:59.000Z

198

ULTRA LOW NOx INTEGRATED SYSTEM FOR NOx EMISSION CONTROL FROM COAL-FIRED BOILERS  

Science Conference Proceedings (OSTI)

ALSTOM Power Inc.'s Power Plant Laboratories, working in concert with ALSTOM Power's Performance Projects Group, has teamed with the U.S. Department of Energy's National Energy Technology Laboratory (DOE NETL) to conduct a comprehensive study to develop/evaluate low-cost, efficient NOx control technologies for retrofit to pulverized coal fired utility boilers. The objective of this project was to develop retrofit NOx control technology to achieve less than 0.15 lb/MMBtu NOx (for bituminous coals) and 0.10 lb/MMBtu NOx (for subbituminous coals) from existing pulverized coal fired utility boilers at a cost which is at least 25% less than SCR technology. Efficient control of NOx is seen as an important, enabling step in keeping coal as a viable part of the national energy mix in this century, and beyond. Presently 57% of U.S. electrical generation is coal based, and the Energy Information Agency projects that coal will maintain a lead in U.S. power generation over all other fuel sources for decades (EIA 1998 Energy Forecast). Yet, coal-based power is being strongly challenged by society's ever-increasing desire for an improved environment and the resultant improvement in health and safety. The needs of the electric-utility industry are to improve environmental performance, while simultaneously improving overall plant economics. This means that emissions control technology is needed with very low capital and operating costs. This project has responded to the industry's need for low NOx emissions by evaluating ideas that can be adapted to present pulverized coal fired systems, be they conventional or low NOx firing systems. The TFS 2000{trademark} firing system has been the ALSTOM Power Inc. commercial offering producing the lowest NOx emission levels. In this project, the TFS 2000{trademark} firing system served as a basis for comparison to other low NOx systems evaluated and was the foundation upon which refinements were made to further improve NOx emissions and related combustion performance. Three coals were evaluated during the bench-scale and large pilot-scale testing tasks. The three coals ranged from a very reactive Powder River Basin coal (PRB) to a moderately reactive Midwestern bituminous coal (HVB) to a less reactive medium volatile Eastern bituminous coal (MVB). Bench-scale testing was comprised of standard ASTM properties evaluation, plus more detailed characterization of fuel properties through drop tube furnace testing and thermogravimetric analysis.

Galen H. Richards; Charles Q. Maney; Richard W. Borio; Robert D. Lewis

2002-12-30T23:59:59.000Z

199

Liquefaction and Pipeline Costs Bruce Kelly  

E-Print Network (OSTI)

1 Liquefaction and Pipeline Costs Bruce Kelly Nexant, Inc. Hydrogen Delivery Analysis Meeting May 8 total installed cost #12;6 Distribution Pipeline Costs Collected historical Oil & Gas Journal data, and surveyed for current urban and downtown data Verified that historical natural gas pipeline cost data

200

Atmospheric Aerosol Source-Receptor Relationships: The Role of Coal-Fired Power Plants  

SciTech Connect

This document serves as the final report for the project Atmospheric Aerosol Source-Receptor Relationships: The Role of Coal-Fired Power Plants supported by the US Department of Energy. The project involved measurement of the ambient fine particle concentrations in the Pittsburgh metropolitan area, development of source profiles for important source classes in the Pittsburgh region, source apportionment using statistical and deterministic air quality models, and investigation of the response in ambient fine particle concentrations to changes in emissions. The project was led by Carnegie Mellon University in collaboration with universities, companies, national laboratories, and regional, state and local air quality agencies. This report describes the overall approach of the project and its major findings.

Robinson, Allen; Pandis, Spyros; Davidson, Cliff

2005-12-31T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

CO2 Mitigation Economics for Existing Coal-Fired Power Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

Engineering & Economic Consultants Engineering & Economic Consultants Website: www.sfapacific.com 444 Castro Street, Suite 720 Mountain View, California 94041 Telephone: (650) 969-8876 Fax: (650) 969-1317 Email: Simbeck@sfapacific.com CO 2 MITIGATION ECONOMICS FOR EXISTING COAL-FIRED POWER PLANTS Presented at the U.S. Dept. of Energy National Energy Technology Laboratory (NETL) First National Conference on Carbon Sequestration May 14-17, 2001 Washington, DC by Dale R. Simbeck Vice President Technology SFA Pacific, Inc. Mountain View, CA ABSTRACT Electric power generation represents one of the largest sources of CO 2 emissions in North America. A major issue in the analysis of CO 2 mitigation options is the fact that over 45% of total electric power generation in North America is from coal. These existing coal-based power

202

Novel Nanocrystalline Intermetallic Coatings for Metal Alloys in Coal-fired Environments  

Science Conference Proceedings (OSTI)

Intermetallic coatings (iron aluminide and nickel aluminide) were prepared by a novel reaction process. In the process, the aluminide coating is formed by an in-situ reaction between the aluminum powder fed through a plasma transferred arc (PTA) torch and the metal substrate (steel or Ni-base alloy). Subjected to the high temperature within an argon plasma zone, aluminum powder and the surface of the substrate melt and react to form the aluminide coatings. The prepared coatings were found to be aluminide phases that are porosity-free and metallurgically bonded to the substrate. The coatings also exhibit excellent high-temperature corrosion resistance under the conditions which simulate the steam-side and fire-side environments in coal-fired boilers. It is expected that the principle demonstrated in this process can be applied to the preparation of other intermetallic and alloy coatings.

Z. Zak Fang; H. Y. Sohn

2009-08-31T23:59:59.000Z

203

OXIDATION OF MERCURY ACROSS SCR CATALYSTS IN COAL-FIRED POWER PLANTS BURNING LOW RANK FUELS  

SciTech Connect

This is the fifth Quarterly Technical Report for DOE Cooperative Agreement No: DE-FC26-03NT41728. The objective of this program is to measure the oxidation of mercury in flue gas across SCR catalyst in a coal-fired power plant burning low rank fuels using a slipstream reactor containing multiple commercial catalysts in parallel. The Electric Power Research Institute (EPRI) and Argillon GmbH are providing co-funding for this program. This program contains multiple tasks and good progress is being made on all fronts. During this quarter, the available data from laboratory, pilot and full-scale SCR units was reviewed, leading to hypotheses about the mechanism for mercury oxidation by SCR catalysts.

Constance Senior

2004-04-30T23:59:59.000Z

204

Modeling of integrated environmental control systems for coal-fired power plants  

SciTech Connect

The Integrated Environmental Control Model (IECM) was designed to permit the systematic evaluation of environmental control options for pulverized coal-fired (PC) power plants. Of special interest was the ability to compare the performance and cost of advanced pollution control systems to conventional'' technologies for the control of particulate, SO{sub 2} and NO{sub x}. Of importance also was the ability to consider pre-combustion, combustion and post-combustion control methods employed alone or in combination to meet tough air pollution emission standards. Finally, the ability to conduct probabilistic analyses is a unique capability of the IECM. Key results are characterized as distribution functions rather than as single deterministic values. (VC)

Rubin, E.S.; Salmento, J.S.; Frey, H.C.; Abu-Baker, A.; Berkenpas, M.

1991-05-01T23:59:59.000Z

205

Modeling of integrated environmental control systems for coal-fired power plants. Final report  

SciTech Connect

The Integrated Environmental Control Model (IECM) was designed to permit the systematic evaluation of environmental control options for pulverized coal-fired (PC) power plants. Of special interest was the ability to compare the performance and cost of advanced pollution control systems to ``conventional`` technologies for the control of particulate, SO{sub 2} and NO{sub x}. Of importance also was the ability to consider pre-combustion, combustion and post-combustion control methods employed alone or in combination to meet tough air pollution emission standards. Finally, the ability to conduct probabilistic analyses is a unique capability of the IECM. Key results are characterized as distribution functions rather than as single deterministic values. (VC)

Rubin, E.S.; Salmento, J.S.; Frey, H.C.; Abu-Baker, A.; Berkenpas, M.

1991-05-01T23:59:59.000Z

206

System design verification of a hybrid geothermal/coal fired power plant  

DOE Green Energy (OSTI)

This hybrid plant utilizes geothermal fluid for feedwater heating. With respect to the extraction of available work from the geothermal fluids, this cycle is approximately two times as efficient as the all geothermal plant. The System Design Verification Study presented verifies the technical and economic feasibility of the hybrid plant. This report is comprised of a conceptual design, cost estimate, and economic analysis of a one-unit 715 MW hybrid geothermal/coal fired power plant. In addition to the use of geothermal fluid for feedwater heating, its use is also investigated for additional power generation, condensate and cooling tower makeup water, coal beneficiation, air preheating, flue gas reheating and plant space heating requirements. An engineering and construction schedule for the hybrid plant is also included.

Not Available

1978-09-01T23:59:59.000Z

207

ASSESSMENT OF LOW COST NOVEL SORBENTS FOR COAL-FIRED POWER PLANT MERCURY CONTROL  

Science Conference Proceedings (OSTI)

This is a Technical Report under a program funded by the Department of Energy's National Energy Technology Laboratory (NETL) to obtain the necessary information to assess the viability of lower cost alternatives to commercially available activated carbon for mercury control in coal-fired utilities. During this reporting period, several sorbent samples have been tested by URS in their laboratory fixed-bed system. The sorbents were evaluated under conditions simulating flue gas from power plants burning Powder River Basin (PRB) and low sulfur eastern bituminous coals. The equilibrium adsorption capacities of the sorbents for both elemental and oxidized mercury are presented. A team meeting discussing the overall program and meetings with Midwest Generation and Wisconsin Electric Power Company (WEPCO) concerning field testing occurred during this reporting period.

Sharon Sjostrom

2002-02-22T23:59:59.000Z

208

Comprehensive assessment of toxic emissions from coal-fired power plants  

SciTech Connect

The 1990 Clean Air Act Amendments (CAAA) have two primary goals: pollution prevention and a market-based least-cost approach to emission control. To address air quality issues as well as permitting and enforcement, the 1990 CAAA contain 11 sections or titles. The individual amendment titles are as follows: Title I - National Ambient Air Quality Standards Title II - Mobile Sources Title III - Hazardous Air Pollutants Title IV - Acid Deposition Control Title V - Permits Title VI - Stratospheric Ozone Protection Chemicals Title VII - Enforcement Title VIII - Miscellaneous Provisions Title IX - Clean Air Research Title X - Disadvantaged Business Concerns Title XI - Clean Air Employment Transition Assistance Titles I, III, IV, and V will change or have the potential to change how operators of coal-fired utility boilers control, monitor, and report emissions. For the purpose of this discussion, Title III is the primary focus.

NONE

1996-09-01T23:59:59.000Z

209

Southern thailand coal fired project: Conceptual design. Volume 3. Export trade information  

SciTech Connect

This study, conducted by Black & Veatch International, was funded by the U.S. Trade and Development Agency. The report addresses various technical, environmental, and economic aspects of developing four 1,000 MW units of coal fired electric generating facilities at a site near Prachuap Khiri Khan. The study includes a cost estimate for the units and the fuel delivery port as well as the major conceptual design decisions made for the project. The study is accompanied by four Conceptual Design manuals. The manual was prepared to communicate project design parameters and requirements to participants of the project, and to control uniformity of design concepts throughout the project. This is Volume 3 of the Conceptual Design manual which is divided into 12 sections pertaining to System Design Specifications.

1995-09-01T23:59:59.000Z

210

Southern thailand coal fired project: Conceptual design. Volume 2. Export trade information  

SciTech Connect

This study, conducted by Black & Veatch International, was funded by the U.S. Trade and Development Agency. The report addresses various technical, environmental, and economic aspects of developing four 1,000 MW units of coal fired electric generating facilities at a site near Prachuap Khiri Khan. The study includes a cost estimate for the units and the fuel delivery port as well as the major conceptual design decisions made for the project. The study is accompanied by four Conceptual Design manuals. The manual was prepared to communicate project design parameters and requirements to participants of the project, and to control uniformity of design concepts throughout the project. This is Volume 2 of the Conceptual Design and is divided into the following sections: (1) General Studies; (2) System Analyses.

1995-09-01T23:59:59.000Z

211

Southern thailand coal fired project: Conceptual design. Volume 4. Export trade information  

SciTech Connect

This study, conducted by Black & Veatch International, was funded by the U.S. Trade and Development Agency. The report addresses various technical, environmental, and economic aspects of developing four 1,000 MW units of coal fired electric generating facilities at a site near Prachuap Khiri Khan. The study includes a cost estimate for the units and the fuel delivery port as well as the major conceptual design decisions made for the project. The study is accompanied by four Conceptual Design manuals. The manual was prepared to commumnicate project design parameters and requirements to participants of the project, and to control uniformity of design concepts throughout the project. This is Volume 4 of the Conceptual Design manual and is divided into 12 sections pertaining to System Design Specifications.

1995-09-01T23:59:59.000Z

212

Development of Cost Effective Oxy-Combustion Technology for Retrofitting Coal-Fired Boilers  

NLE Websites -- All DOE Office Websites (Extended Search)

Cost effeCtive Cost effeCtive oxy-Combustion teChnology for retrofitting Coal-fireD boilers Background Electric power generation from fossil fuels represents one of the largest contributors to greenhouse gas emissions, not just in the United States, but throughout the world. Various technologies and concepts are being investigated as means to mitigate carbon dioxide (CO 2 ) emissions. The concept of pulverized coal (PC) oxy-combustion is one potential economical solution, whereby coal is combusted in an enriched oxygen environment using pure oxygen diluted with recycled flue gas. In this manner, the flue gas is composed primarily of CO 2 and H 2 O, so that a concentrated stream of CO 2 is produced by simply condensing the water in the exhaust stream. An advantage of

213

The low moisture eastern coal processing system at the UTSI-DOE Coal Fired Flow Facility  

DOE Green Energy (OSTI)

A low moisture, eastern coal processing system was constructed at the Department of Energy`s Coal Fired Flow Facility (CFFF), located at the University of Tennessee Space Institute in Tullahoma, Tennessee, to provide a metered and regulated supply of seeded, pulverized coal to support magnetohydrodynamic (MHD) power generation research. The original system configuration is described as well as major modifications made in response to specific operational problems. Notable among these was the in-house development of the Moulder flow control valve which exhibited marked improvement in durability compared to previous valves used with pulverized coal. Coal processing system performance parameters are discussed. A summary of tests conducted and significant events are included.

Evans, B.R.; Washington, E.S.; Sanders, M.E.

1993-10-01T23:59:59.000Z

214

Life Cycle Greenhouse Gas Emissions of Coal-Fired Electricity Generation: Systematic Review and Harmonization  

Science Conference Proceedings (OSTI)

This systematic review and harmonization of life cycle assessments (LCAs) of utility-scale coal-fired electricity generation systems focuses on reducing variability and clarifying central tendencies in estimates of life cycle greenhouse gas (GHG) emissions. Screening 270 references for quality LCA methods, transparency, and completeness yielded 53 that reported 164 estimates of life cycle GHG emissions. These estimates for subcritical pulverized, integrated gasification combined cycle, fluidized bed, and supercritical pulverized coal combustion technologies vary from 675 to 1,689 grams CO{sub 2}-equivalent per kilowatt-hour (g CO{sub 2}-eq/kWh) (interquartile range [IQR]= 890-1,130 g CO{sub 2}-eq/kWh; median = 1,001) leading to confusion over reasonable estimates of life cycle GHG emissions from coal-fired electricity generation. By adjusting published estimates to common gross system boundaries and consistent values for key operational input parameters (most importantly, combustion carbon dioxide emission factor [CEF]), the meta-analytical process called harmonization clarifies the existing literature in ways useful for decision makers and analysts by significantly reducing the variability of estimates ({approx}53% in IQR magnitude) while maintaining a nearly constant central tendency ({approx}2.2% in median). Life cycle GHG emissions of a specific power plant depend on many factors and can differ from the generic estimates generated by the harmonization approach, but the tightness of distribution of harmonized estimates across several key coal combustion technologies implies, for some purposes, first-order estimates of life cycle GHG emissions could be based on knowledge of the technology type, coal mine emissions, thermal efficiency, and CEF alone without requiring full LCAs. Areas where new research is necessary to ensure accuracy are also discussed.

Whitaker, M.; Heath, G. A.; O'Donoughue, P.; Vorum, M.

2012-04-01T23:59:59.000Z

215

A Review of Hazardous Chemical Species Associated with CO2 Capture from Coal-Fired Power Plants and Their Potential Fate in CO2 Geologic Storage  

E-Print Network (OSTI)

in an Industrial-Scale Boiler. The Fifteenth Internationala Coal-Fired Fluidized- Bed Boiler. Proceedings of the 15 thhere. A (2 MMBtu) research boiler (Falcone Miller et al. ,

Apps, J.A.

2006-01-01T23:59:59.000Z

216

A Review of Hazardous Chemical Species Associated with CO2 Capture from Coal-Fired Power Plants and Their Potential Fate in CO2 Geologic Storage  

E-Print Network (OSTI)

evaluation of an oxyfuel power plant using mixed conductingA Vision for Thermal Power-Plant Technology Development inon an Existing US Coal-Fired Power Plant . First National

Apps, J.A.

2006-01-01T23:59:59.000Z

217

A Review of Hazardous Chemical Species Associated with CO2 Capture from Coal-Fired Power Plants and Their Potential Fate in CO2 Geologic Storage  

E-Print Network (OSTI)

and related Natural Gas Combined Cycle (NGCC) power plantspower plants, petroleum refining, chemical processing industries, and natural gasnatural gas. If CO 2 capture and geologic sequestration from coal-fired power plants

Apps, J.A.

2006-01-01T23:59:59.000Z

218

A Review of DOE/NETLs Advanced NOx Control Technology R&D Program for Coal-Fired Power Plants. National Energy Technology Laboratory  

E-Print Network (OSTI)

The environmental performance of the United States fleet of coal-fired boilers has steadily improved since passage of the 1990 Clean Air Act Amendments (CAAA). Missions of sulfur dioxide (SO

Bruce W. Lani; Thomas J. Feeley; James Murphy; Lindsay Green

2005-01-01T23:59:59.000Z

219

Membrane Process to Capture CO{sub 2} from Coal-Fired Power Plant Flue Gas  

SciTech Connect

This final report describes work conducted for the U.S. Department of Energy National Energy Technology Laboratory (DOE NETL) on development of an efficient membrane process to capture carbon dioxide (CO{sub 2}) from power plant flue gas (award number DE-NT0005312). The primary goal of this research program was to demonstrate, in a field test, the ability of a membrane process to capture up to 90% of CO{sub 2} in coal-fired flue gas, and to evaluate the potential of a full-scale version of the process to perform this separation with less than a 35% increase in the levelized cost of electricity (LCOE). Membrane Technology and Research (MTR) conducted this project in collaboration with Arizona Public Services (APS), who hosted a membrane field test at their Cholla coal-fired power plant, and the Electric Power Research Institute (EPRI) and WorleyParsons (WP), who performed a comparative cost analysis of the proposed membrane CO{sub 2} capture process. The work conducted for this project included membrane and module development, slipstream testing of commercial-sized modules with natural gas and coal-fired flue gas, process design optimization, and a detailed systems and cost analysis of a membrane retrofit to a commercial power plant. The Polaris membrane developed over a number of years by MTR represents a step-change improvement in CO{sub 2} permeance compared to previous commercial CO{sub 2}-selective membranes. During this project, membrane optimization work resulted in a further doubling of the CO{sub 2} permeance of Polaris membrane while maintaining the CO{sub 2}/N{sub 2} selectivity. This is an important accomplishment because increased CO{sub 2} permeance directly impacts the membrane skid cost and footprint: a doubling of CO{sub 2} permeance halves the skid cost and footprint. In addition to providing high CO{sub 2} permeance, flue gas CO{sub 2} capture membranes must be stable in the presence of contaminants including SO{sub 2}. Laboratory tests showed no degradation in Polaris membrane performance during two months of continuous operation in a simulated flue gas environment containing up to 1,000 ppm SO{sub 2}. A successful slipstream field test at the APS Cholla power plant was conducted with commercialsize Polaris modules during this project. This field test is the first demonstration of stable performance by commercial-sized membrane modules treating actual coal-fired power plant flue gas. Process design studies show that selective recycle of CO{sub 2} using a countercurrent membrane module with air as a sweep stream can double the concentration of CO{sub 2} in coal flue gas with little energy input. This pre-concentration of CO{sub 2} by the sweep membrane reduces the minimum energy of CO{sub 2} separation in the capture unit by up to 40% for coal flue gas. Variations of this design may be even more promising for CO{sub 2} capture from NGCC flue gas, in which the CO{sub 2} concentration can be increased from 4% to 20% by selective sweep recycle. EPRI and WP conducted a systems and cost analysis of a base case MTR membrane CO{sub 2} capture system retrofitted to the AEP Conesville Unit 5 boiler. Some of the key findings from this study and a sensitivity analysis performed by MTR include: The MTR membrane process can capture 90% of the CO{sub 2} in coal flue gas and produce high-purity CO{sub 2} (>99%) ready for sequestration. CO{sub 2} recycle to the boiler appears feasible with minimal impact on boiler performance; however, further study by a boiler OEM is recommended. For a membrane process built today using a combination of slight feed compression, permeate vacuum, and current compression equipment costs, the membrane capture process can be competitive with the base case MEA process at 90% CO{sub 2} capture from a coal-fired power plant. The incremental LCOE for the base case membrane process is about equal to that of a base case MEA process, within the uncertainty in the analysis. With advanced membranes (5,000 gpu for CO{sub 2} and 50 for CO{sub 2}/N{sub 2}), operating with no feed compression and

Merkel, Tim; Wei, Xiaotong; Firat, Bilgen; He, Jenny; Amo, Karl; Pande, Saurabh; Baker, Richard; Wijmans, Hans; Bhown, Abhoyjit

2012-03-31T23:59:59.000Z

220

TOXECON Retrofit for Mercury and Multi-Pollutant Control on Three 90 MW Coal-Fired Boilers (Completed September 30, 2009)  

NLE Websites -- All DOE Office Websites (Extended Search)

TOXECON Retrofit for Mercury and TOXECON Retrofit for Mercury and Multi-Pollutant Control on Three 90 MW Coal-Fired Boilers (Completed September 30, 2009) Project Description Wisconsin Electric Power Company (We Energies) has designed, installed, operated, and evaluated the TOXECON process as an integrated mercury, particulate matter, SO 2 , and NO X emissions control system for application on coal-fired power generation systems. TOXECON is a process in which sorbents, including powdered activated

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

BRUCE CHILDERS http://www.cs.pitt.edu/PCM  

E-Print Network (OSTI)

in 2011 ¨ 30 new coal fired power plants by 2015 ¨ CO2 half of airline and third of steel industries ¨ CO2 childers@cs.pitt.edu Surfing the Wave of Emerging Hybrid Memory Architectures image source: Wikipedia Data, several studies show the contribution of memory to the total cost and power consumption of future systems

Childers, Bruce

222

Evaluation of Mercury Emissions from Coal-Fired Facilities with SCR and FGD Systems  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP)--wet flue gas desulfurization (FGD) combination or a spray dyer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The principal purpose of this work is to develop a better understanding of the potential mercury removal ''co-benefits'' achieved by NO{sub x}, and SO{sub 2} control technologies. It is expected that these data will provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. Ultimately, this insight could help to design and operate SCR and FGD systems to maximize mercury removal. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of SCR catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. This document, the ninth in a series of topical reports, describes the results and analysis of mercury sampling performed on Unit 1 at Plant 7, a 566 MW unit burning a bituminous coal containing 3.6% sulfur. The unit is equipped with a SCR, ESP, and wet FGD to control NO{sub x}, particulate, and SO{sub 2} emissions, respectively. Four sampling tests were performed in August 2004 during ozone season with the SCR operating; flue gas mercury speciation and concentrations were determined at the SCR inlet, SCR outlet, air heater outlet (ESP inlet), ESP outlet (FGD inlet), and at the stack (FGD outlet) using the Ontario Hydro method. Three sampling tests were also performed in November 2004 during non-ozone season with the SCR bypassed; flue gas mercury speciation and concentrations were determined at the ESP outlet (FGD inlet), and at the stack (FGD outlet). Process samples for material balances were collected during the flue gas measurements. The results show that, at the point where the flue gas enters the FGD, a greater percentage of the mercury was in the oxidized form when the SCR was operating compared to when the SCR was bypassed (97% vs 91%). This higher level of oxidation resulted in higher mercury removals in the FGD because the FGD removed 90-94% of the oxidized mercury in both cases. Total coal-to-stack mercury removal was 86% with the SCR operating, and 73% with the SCR bypassed. The average mercury mass balance closure was 81% during the ozone season tests and 87% during the non-ozone season tests.

J. A. Withum; S. C. Tseng; J. E. Locke

2006-01-31T23:59:59.000Z

223

EVALUATION OF MERCURY EMISSIONS FROM COAL-FIRED FACILITIES WITH SCR AND FGD SYSTEMS  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP) - wet flue gas desulfurization (FGD) combination or a spray dyer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on Hg speciation and the efficacy of different FGD technologies for Hg capture. This document, the second in a series of topical reports, describes the results and analysis of mercury sampling performed on a 330 MW unit burning a bituminous coal containing 1.0% sulfur. The unit is equipped with a SCR system for NOx control and a spray dryer absorber for SO{sub 2} control followed by a baghouse unit for particulate emissions control. Four sampling tests were performed in March 2003. Flue gas mercury speciation and concentrations were determined at the SCR inlet, air heater outlet (ESP inlet), and at the stack (FGD outlet) using the Ontario Hydro method. Process stream samples for a mercury balance were collected to coincide with the flue gas measurements. Due to mechanical problems with the boiler feed water pumps, the actual gross output was between 195 and 221 MW during the tests. The results showed that the SCR/air heater combination oxidized nearly 95% of the elemental mercury. Mercury removal, on a coal-to-stack basis, was 87%. The mercury material balance closures for the four tests conducted at the plant ranged from 89% to 114%, with an average of 100%. These results appear to show that the SCR had a positive effect on mercury removal. In earlier programs, CONSOL sampled mercury at six plants with wet FGDs for SO{sub 2} control without SCR catalysts. At those plants, an average of 61 {+-} 15% of the mercury was in the oxidized form at the air heater outlet. The principal purpose of this work is to develop a better understanding of the potential Hg removal ''co-benefits'' achieved by NOx, and SO{sub 2} control technologies. It is expected that this data will provide the basis for fundamental scientific insights into the nature of Hg chemistry in flue gas, the catalytic effect of SCR systems on Hg speciation and the efficacy of different FGD technologies for Hg capture. Ultimately, this insight could help to design and operate SCR and FGD systems to maximize Hg removal.

J. A. Withum; S.C. Tseng; J. E. Locke

2004-10-31T23:59:59.000Z

224

EVALUATION OF MERCURY EMISSIONS FROM COAL-FIRED FACILITIES WITH SCR AND FGD SYSTEMS  

SciTech Connect

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP)--wet flue gas desulfurization (FGD) combination or a spray dryer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. This document, the seventh in a series of topical reports, describes the results and analysis of mercury sampling performed on a 1,300 MW unit burning a bituminous coal containing three percent sulfur. The unit was equipped with an ESP and a limestone-based wet FGD to control particulate and SO2 emissions, respectively. At the time of sampling an SCR was not installed on this unit. Four sampling tests were performed in September 2003. Flue gas mercury speciation and concentrations were determined at the ESP outlet (FGD inlet), and at the stack (FGD outlet) using the Ontario Hydro method. Process stream samples for a mercury balance were collected to coincide with the flue gas measurements. The results show that the FGD inlet flue gas oxidized:elemental mercury ratio was roughly 2:1, with 66% oxidized mercury and 34% elemental mercury. Mercury removal, on a coal-to-stack basis, was 53%. The average Hg concentration in the stack flue gas was 4.09 {micro}g/m{sup 3}. The average stack mercury emission was 3.47 Ib/TBtu. The mercury material balance closures ranged from 87% to 108%, with an average of 97%. A sampling program similar to this one was performed on a similar unit (at the same plant) that was equipped with an SCR for NOx control. Comparison of the results from the two units show that the SCR increases the percentage of mercury that is in the oxidized form, which, in turn, lends to more of the total mercury being removed in the wet scrubber. The principal purpose of this work is to develop a better understanding of the potential mercury removal ''co-benefits'' achieved by NOx, and SO{sub 2} control technologies. It is expected that this data will provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. Ultimately, this insight could help to design and operate SCR and FGD systems to maximize mercury removal.

J.A. Withum; S.C. Tseng; J.E. Locke

2005-11-01T23:59:59.000Z

225

Evaluation of Mercury Emissions from Coal-Fired Facilities with SCR and FGD Systems  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP)--wet flue gas desulfurization (FGD) combination or a spray dyer absorber--fabric filter (SDA-FF) combination. In this program CONSOL is determining mercury speciation and removal at 10 coal-fired facilities. The principal purpose of this work is to develop a better understanding of the potential mercury removal ''co-benefits'' achieved by NO{sub x}, and SO{sub 2} control technologies. It is expected that this data will provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. Ultimately, this insight could help to design and operate SCR and FGD systems to maximize mercury removal. The objectives are (1) to evaluate the effect of SCR on mercury capture in the ESP-FGD and SDA-FF combinations at coal-fired power plants, (2) evaluate the effect of SCR catalyst degradation on mercury capture; (3) evaluate the effect of low load operation on mercury capture in an SCR-FGD system, and (4) collect data that could provide the basis for fundamental scientific insights into the nature of mercury chemistry in flue gas, the catalytic effect of SCR systems on mercury speciation and the efficacy of different FGD technologies for mercury capture. This document, the tenth in a series of topical reports, describes the results and analysis of mercury sampling performed on two 468 MW units burning bituminous coal containing 1.3-1.7% sulfur. Unit 2 is equipped with an SCR, ESP, and wet FGD to control NO{sub x}, particulate, and SO{sub 2} emissions, respectively. Unit 1 is similar to Unit 2, except that Unit 1 has no SCR for NOx control. Four sampling tests were performed on both units in January 2005; flue gas mercury speciation and concentrations were determined at the economizer outlet, air heater outlet (ESP inlet), ESP outlet (FGD inlet), and at the stack (FGD outlet) using the Ontario Hydro method. Process samples for material balances were collected with the flue gas measurements. The results show that the SCR increased the oxidation of the mercury at the air heater outlet. At the exit of the air heater, a greater percentage of the mercury was in the oxidized and particulate forms on the unit equipped with an SCR compared to the unit without an SCR (97.4% vs 91%). This higher level of oxidation resulted in higher mercury removals in the scrubber. Total mercury removal averaged 97% on the unit with the SCR, and 87% on the unit without the SCR. The average mercury mass balance closure was 84% on Unit 1 and 103% on Unit 2.

J. A. Withum; J. E. Locke

2006-02-01T23:59:59.000Z

226

TOXECON RETROFIT FOR MERCURY AND MULTI-POLLUTANT CONTROL ON THREE 90 MW COAL FIRED BOILERS  

Science Conference Proceedings (OSTI)

With the Nation's coal-burning utilities facing tighter controls on mercury pollutants, the U.S. Department of Energy is supporting projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by a particle control device along with the other solid material, primarily fly ash. WE Energies has over 3,700 MW of coal-fired generating capacity and supports an integrated multi-emission control strategy for SO{sub 2}, NO{sub x} and mercury emissions while maintaining a varied fuel mix for electric supply. The primary goal of this project is to reduce mercury emissions from three 90 MW units that burn Powder River Basin coal at the WE Energies Presque Isle Power Plant. Additional goals are to reduce nitrogen oxide (NO{sub x}), sulfur dioxide (SO{sub 2}), and particulate matter (PM) emissions, allow for reuse and sale of fly ash, demonstrate a reliable mercury continuous emission monitor (CEM) suitable for use in the power plant environment, and demonstrate a process to recover mercury captured in the sorbent. To achieve these goals, WE Energies (the Participant) will design, install, and operate a TOXECON{trademark} (TOXECON) system designed to clean the combined flue gases of units 7, 8, and 9 at the Presque Isle Power Plant. TOXECON is a patented process in which a fabric filter system (baghouse) installed down stream of an existing particle control device is used in conjunction with sorbent injection for removal of pollutants from combustion flue gas. For this project, the flue gas emissions will be controlled from the three units using a single baghouse. Mercury will be controlled by injection of activated carbon or other novel sorbents, while NO{sub x} and SO{sub 2} will be controlled by injection of sodium based or other novel sorbents. Addition of the TOXECON baghouse will provide enhanced particulate control. Sorbents will be injected downstream of the existing particle collection device to allow for continued sale and reuse of captured fly ash from the existing particulate control device, uncontaminated by activated carbon or sodium sorbents. Methods for sorbent regeneration, i.e. mercury recovery from the sorbent, will be explored and evaluated. For mercury concentration monitoring in the flue gas streams, components available for use will be evaluated and the best available will be integrated into a mercury CEM suitable for use in the power plant environment. This project will provide for the use of a novel multi-pollutant control system to reduce emissions of mercury and other air pollutants, while minimizing waste, from a coal-fired power generation system.

Richard E. Johnson

2004-07-30T23:59:59.000Z

227

Characterization of Oxy-combustion Impacts in Existing Coal-fired Boilers  

SciTech Connect

This report summarizes Year 1 results of a research program designed to use multi-scale experimental studies and fundamental theoretical models to characterize and predict the impacts of retrofit of existing coal-fired utility boilers for oxy-combustion. Through the course of Year 1 activities, great progress was made toward understanding the issues associated with oxy-combustion retrofit of coal-fired boilers. All four Year 1 milestones and objectives have been, or will be, completed on schedule and within budget. Progress in the four milestone areas may be summarized as follows: University of Utah has performed size segregated ash composition measurements in the Oxy-Fuel Combustor (OFC). These experiments indicate that oxy-combustion retrofit may impact ash aerosol mineral matter composition. Both flame temperature and flue gas composition have been observed to influence the concentration of calcium, magnesium and iron in the fine particulate. This could in turn impact boiler fouling and slagging. Sandia National Labs has shown that char oxidation rate is dependent on particle size (for sizes between 60 and 100 microns) by performing fundamental simulations of reacting char particles. These predictions will be verified by making time-resolved optical measurements of char particle temperature, velocity and size in bench-scale experiments before the end of Year 1. REI and Siemens have completed the design of an oxy-research burner that will be mounted on University of Utahs pilot-scale furnace, the L1500. This burner will accommodate a wide range of O2, FGR and mixing strategies under conditions relevant for utility boiler operation. Through CFD modeling of the different burner designs, it was determined that the key factor influencing flame stabilization location is particle heat-up rate. The new oxy-research burner and associated equipment is scheduled for delivery before the end of Year 1. REI has completed a literature survey of slagging and fouling mechanisms in coal-fired power plants to understand key issues influencing these deposition regimes and infer their behavior under oxy-fired conditions. Based on the results of this survey, an algorithm for integrating slagging predictions into CFD models was outlined. This method accounts for ash formation, particle impaction and sticking, deposit growth and physical properties and impact of the deposit on system flow and heat transfer. A model for fouling in the back pass has also been identified which includes vaporization of sodium, deposition of sodium sulfate on fly ash particles and tube surfaces, and deposit growth rate on tubes. In Year 1, REI has also performed a review of the literature describing corrosion in order to understand the behavior of oxidation, sulfidation, chloridation, and carburization mechanisms in air-fired and oxy-combustion systems. REI and Vattenfall have met and exchanged information concerning oxy-coal combustion mechanisms for CFD simulations currently used by Vattenfall. In preparation for Year 2 of this program, two coals (North Antelope PRB, Western bituminous) have been ordered, pulverized and delivered to the University of Utah and Sandia National Labs. Materials for the corrosion experiments have been identified, suppliers located, and a schedule for equipment fabrication and shakedown has been established. Finally, a flue gas recycle system has been designed and is being constructed for the OFC.

Bradley Adams; Andrew Fry; Constance Senior; Hong Shim; Huafeng Wang; Jost Wendt; Christopher Shaddix

2009-06-30T23:59:59.000Z

228

Development and Testing of Industrial Scale Coal Fired Combustion System, Phase 3  

SciTech Connect

Coal Tech Corp's mission is to develop, license & sell innovative, lowest cost, solid fuel fired power systems & total emission control processes using proprietary and patented technology for domestic and international markets. The present project 'DEVELOPMENT & TESTING OF INDUSTRIAL SCALE, COAL FIRED COMBUSTION SYSTEM, PHASE 3' on DOE Contract DE-AC22-91PC91162 was a key element in achieving this objective. The project consisted of five tasks that were divided into three phases. The first phase, 'Optimization of First Generation 20 MMBtu/hr Air-Cooled Slagging Coal Tech Combustor', consisted of three tasks, which are detailed in Appendix 'A' of this report. They were implemented in 1992 and 1993 at the first generation, 20 MMBtu/hour, combustor-boiler test site in Williamsport, PA. It consisted of substantial combustor modifications and coal-fired tests designed to improve the combustor's wall cooling, slag and ash management, automating of its operation, and correcting severe deficiencies in the coal feeding to the combustor. The need for these changes was indicated during the prior 900-hour test effort on this combustor that was conducted as part of the DOE Clean Coal Program. A combination of combustor changes, auxiliary equipment changes, sophisticated multi-dimensional combustion analysis, computer controlled automation, and series of single and double day shift tests totaling about 300 hours, either resolved these operational issues or indicated that further corrective changes were needed in the combustor design. The key result from both analyses and tests was that the combustor must be substantially lengthened to maximize combustion efficiency and sharply increase slag retention in the combustor. A measure of the success of these modifications was realized in the third phase of this project, consisting of task 5 entitled: 'Site Demonstration with the Second Generation 20 MMBtu/hr Air-Cooled Slagging Coal Tech Combustor'. The details of the task 5 effort are contained in Appendix 'C'. It was implemented between 1994 and 1998 after the entire 20 MMBtu/hr combustor-boiler facility was relocated to Philadelphia, PA in 1994. A new test facility was designed and installed. A substantially longer combustor was fabricated. Although not in the project plan or cost plan, an entire steam turbine-electric power generating plant was designed and the appropriate new and used equipment for continuous operation was specified. Insufficient funds and the lack of a customer for any electric power that the test facility could have generated prevented the installation of the power generating equipment needed for continuous operation. All other task 5 project measures were met and exceeded. 107 days of testing in task 5, which exceeded the 63 days (about 500 hours) in the test plan, were implemented. Compared to the first generation 20 MMBtu/hr combustor in Williamsport, the 2nd generation combustor has a much higher combustion efficiency, the retention of slag inside the combustor doubled to about 75% of the coal ash, and the ash carryover into the boiler, a major problem in the Williamsport combustor was essentially eliminated. In addition, the project goals for coal-fired emissions were exceeded in task 5. SO{sub 2} was reduced by 80% to 0.2 lb/MMBtu in a combination of reagent injection in the combustion and post-combustion zones. NO{sub x} was reduced by 93% to 0.07 lb/MMBtu in a combination of staged combustion in the combustor and post-combustion reagent injection. A baghouse was installed that was rated to 0.03 lb/MMBtu stack particle emissions. The initial particle emission test by EPA Method 5 indicated substantially higher emissions far beyond that indicated by the clear emission plume. These emissions were attributed to steel particles released by wall corrosion in the baghouse, correction of which had no effect of emissions.

Bert Zauderer

1998-09-30T23:59:59.000Z

229

Capturing and Sequestering CO2 from a Coal-Fired Power Plant - Assessing the Net Energy and Greenhouse Gas Emissions  

NLE Websites -- All DOE Office Websites (Extended Search)

Capturing and Sequestering CO Capturing and Sequestering CO 2 from a Coal-fired Power Plant - Assessing the Net Energy and Greenhouse Gas Emissions Pamela L. Spath (pamela_spath @nrel.gov; (303) 275-4460) Margaret K. Mann (margaret_mann @nrel.gov; (303) 275-2921) National Renewable Energy Laboratory 1617 Cole Boulevard Golden, CO 80401 INTRODUCTION It is technically feasible to capture CO 2 from the flue gas of a coal-fired power plant and various researchers are working to understand the fate of sequestered CO 2 and its long term environmental effects. Sequestering CO 2 significantly reduces the CO 2 emissions from the power plant itself, but this is not the total picture. CO 2 capture and sequestration consumes additional energy, thus lowering the plant's fuel to electricity efficiency. To compensate for this, more fossil fuel must be

230

Coal-fired high performance power generating system. Draft quarterly progress report, January 1--March 31, 1995  

SciTech Connect

This report covers work carried out under Task 3, Preliminary R and D, under contract DE-AC22-92PC91155, ``Engineering Development of a Coal-Fired High Performance Power Generation System`` between DOE Pittsburgh Energy Technology Center and United Technologies Research Center. The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of >47% thermal efficiency; NO{sub x}, SO{sub x} and particulates {le} 25% NSPS; cost {ge}65% of heat input; all solid wastes benign. A crucial aspect of the authors design is the integration of the gas turbine requirements with the HITAF output and steam cycle requirements. In order to take full advantage of modern highly efficient aeroderivative gas turbines they have carried out a large number of cycle calculations to optimize their commercial plant designs for both greenfield and repowering applications.

1995-10-01T23:59:59.000Z

231

Coal-fired high performance power generating system. Quarterly progress report, July 1, 1993--September 30, 1993  

Science Conference Proceedings (OSTI)

This report covers work carried out under Task 3, Preliminary Research and Development, and Task 4, Commercial Generating Plant Design, under contract DE-AC22-92PC91155, {open_quotes}Engineering Development of a Coal Fired High Performance Power Generation System{close_quotes} between DOE Pittsburgh Energy Technology Center and United Technologies Research Center. The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of >47% thermal efficiency; NO{sub x}, SO{sub x}, and particulates {le} 25% NSPS; cost {ge} 65% of heat input; and all solid wastes benign. The report discusses progress in cycle analysis, chemical reactor modeling, ash deposition rate calculations for HITAF (high temperature advanced furnace) convective air heater, air heater materials, and deposit initiation and growth on ceramic substrates.

Not Available

1993-12-31T23:59:59.000Z

232

The high moisture western coal processing system at the UTSI-DOE Coal Fired Flow Facility. Topical report  

DOE Green Energy (OSTI)

The original eastern coal processing system at the Department of Energy`s Coal Fired Flow Facility (CFFF), located at the University of Tennessee Space Institute in Tullahoma, Tennessee, was modified to pulverize and dry Montana Rosebud, a western coal. Significant modifications to the CFFF coal processing system were required and the equipment selection criteria are reviewed. Coal processing system performance parameters are discussed. A summary of tests conducted and significant events are included.

Sanders, M.E.

1996-02-01T23:59:59.000Z

233

New 90,000 PPH Coal Fired Boiler Plant at Liggett & Myers Tobacco Company, Durham North Carolina  

E-Print Network (OSTI)

Liggett & Myers Tobacco Company in Durham, North Carolina is installing a future cogeneration, coal fired boiler system designed and built by Energy Systems (ESI) of Chattanooga, Tennessee. The complete boiler plant is comprised of a 90,000 pph Dorr-Oliver/E.Keeler, 750 psig design boiler for future cogeneration with a Detroit chain grate stoker and all necessary coal conveying equipment, silos, side stream bag house, buildings and also, all necessary auxiliary equipment to make for a complete operating system.

Kaskey, G. T.

1984-01-01T23:59:59.000Z

234

Market-Based Valuation of New Coal-Fired Generation: Case Studies of Investment Risk and Profitability  

Science Conference Proceedings (OSTI)

Natural gas turbine technology has dominated new generation capacity additions in the United States, yet several years of unexpectedly high natural gas prices are driving interest in alternatives. This report uses case studies of new coal-fired generation to address the question of whether coal can be a good choice for the private investor. The studies give great detail on possible coal plants in Texas and some guidance on possible projects in Virginia, Ohio, and Indiana. The studies provide a comprehens...

2003-03-26T23:59:59.000Z

235

Nitrogen oxides emission control through reburning with biomass in coal-fired power plants  

E-Print Network (OSTI)

Oxides of nitrogen from coal-fired power stations are considered to be major pollutants, and there is increasing concern for regulating air quality and offsetting the emissions generated from the use of energy. Reburning is an in-furnace, combustion control technology for NOx reduction. Another environmental issue that needs to be addressed is the rapidly growing feedlot industry in the United States. The production of biomass from one or more animal species is in excess of what can safely be applied to farmland in accordance with nutrient management plans and stockpiled waste poses economic and environmental liabilities. In the present study, the feasibility of using biomass as a reburn fuel in existing coal-fired power plants is considered. It is expected to utilize biomass as a low-cost, substitute fuel and an agent to control emission. The successful development of this technology will create environment-friendly, low cost fuel source for the power industry, provide means for an alternate method of disposal of biomass, and generate a possible revenue source for feedlot operators. In the present study, the effect of coal, cattle manure or feedlot biomass, and blends of biomass with coal on the ability to reduce NOx were investigated in the Texas A&M University 29.31 kW (100,000 Btu/h) reburning facility. The facility used a mixture of propane and ammonia to generate the 600 ppm NOx in the primary zone. The reburn fuel was injected using air. The stoichiometry tested were 1.00 to 1.20 in the reburn zone. Two types of injectors, circular jet and fan spray injectors, which produce different types of mixing within the reburn zone, were studied to find their effect on NOx emissions reduction. The flat spray injector performed better in all cases. With the injection of biomass as reburn fuel with circular jet injector the maximum NOx reduction was 29.9 % and with flat spray injector was 62.2 %. The mixing time was estimated in model set up as 936 and 407 ms. The maximum NOx reduction observed with coal was 14.4 % and with biomass it was 62.2 % and the reduction with blends lay between that of coal and biomass.

Arumugam, Senthilvasan

2004-12-01T23:59:59.000Z

236

Proceedings of the coal-fired power systems 94: Advances in IGCC and PFBC review meeting. Volume 2  

Science Conference Proceedings (OSTI)

The Coal-Fired Power Systems 94 -- Advances in IGCC and PFBC Review Meeting was held June 21--23, 1994, at the Morgantown Energy Center (METC) in Morgantown, West Virginia. This Meeting was sponsored and hosted by METC, the Office of Fossil Energy, and the US Department of Energy (DOE). METC annually sponsors this conference for energy executives, engineers, scientists, and other interested parties to review the results of research and development projects; to discuss the status of advanced coal-fired power systems and future plans with the industrial contractors; and to discuss cooperative industrial-government research opportunities with METC`s in-house engineers and scientists. Presentations included industrial contractor and METC in-house technology developments related to the production of power via coal-fired Integrated Gasification Combined Cycle (IGCC) and Pressurized Fluidized Bed Combustion (PFBC) systems, the summary status of clean coal technologies, and developments and advancements in advanced technology subsystems, such as hot gas cleanup. A keynote speaker and other representatives from the electric power industry also gave their assessment of advanced power systems. This meeting contained 11 formal sessions and one poster session, and included 52 presentations and 24 poster presentations. Volume II contains papers presented at the following sessions: filter technology issues; hazardous air pollutants; sorbents and solid wastes; and membranes. Selected papers have been processed separately for inclusion in the Energy Science and Technology Database.

McDaniel, H.M.; Staubly, R.K.; Venkataraman, V.K. [eds.

1994-06-01T23:59:59.000Z

237

Conference on alternatives for pollution control from coal-fired low emission sources, Plzen, Czech Republic. Plzen Proceedings  

SciTech Connect

The Conference on Alternatives for Pollution Control from Coal-Fired Emission Sources presented cost-effective approaches for pollution control of low emission sources (LES). It also identified policies and strategies for implementation of pollution control measures at the local level. Plzen, Czech Republic, was chosen as the conference site to show participants first hand the LES problems facing Eastern Europe today. Collectively, these Proceedings contain clear reports on: (a) methods for evaluating the cost effectiveness of alternative approaches to control pollution from small coal-fired boilers and furnaces; (b) cost-effective technologies for controlling pollution from coal-fired boilers and furnaces; (c) case studies of assessment of cost effective pollution control measures for selected cities in eastern Europe; and (d) approaches for actually implementing pollution control measures in cities in Eastern Europe. It is intended that the eastern/central European reader will find in these Proceedings useful measures that can be applied to control emissions and clean the air in his city or region. The conference was sponsored by the United States Agency for International Development (AID), the United States Department of Energy (DOE), and the Czech Ministry of Industry and Trade. Selected papers have been indexed separately for inclusion in the Energy Science and Technology Database.

Not Available

1994-07-01T23:59:59.000Z

238

Novel regenerable sorbent for mercury capture from flue gases of coal-fired power plant  

Science Conference Proceedings (OSTI)

A natural chabazite-based silver nanocomposite (AgMC) was synthesized to capture mercury from flue gases of coal-fired power plants. Silver nanoparticles were engineered on zeolite through ion-exchange of sodium ions with silver ions, followed by thermal annealing. Mercury sorption test using AgMC was performed at various temperatures by exposing it to either pulse injection of mercury or continuous mercury flow. A complete capture of mercury by AgMC was achieved up to a capture temperature of 250{sup o}C. Nano silver particles were shown to be the main active component for mercury capture by amalgamation mechanism. Compared with activated carbon-based sorbents, the sorbent prepared in this study showed a much higher mercury capture capacity and upper temperature limit for mercury capture. More importantly, the mercury captured by the spent AgMC could be easily released for safe disposal and the sorbent regenerated by simple heating at 400{sup o}C. Mercury capture tests performed in real flue gas environment showed a much higher level of mercury capture by AgMC than by other potential mercury sorbents tested. In our mercury capture tests, the AgMC exposed to real flue gases showed an increased mercury capture efficiency than the fresh AgMC. 38 refs., 6 figs.

Yan Liu; David J.A. Kelly; Hongqun Yang; Christopher C.H. Lin; Steve M. Kuznicki; Zhenghe Xu [University of Alberta, Edmonton, AB (Canada). Department of Chemical and Materials Engineering

2008-08-15T23:59:59.000Z

239

The Magnetohydrodynamics Coal-Fired Flow Facility technical progress report, July 1, 1993--September 30, 1993  

DOE Green Energy (OSTI)

In this quarterly technical progress report, UTSI reports on a multi-task research contract directed toward developing the technology for an MHD steam combined cycle power plant. During the period two tests were conducted in the DOE Coal Fired FLow Facility. Both of these tests were part of the western coal proof-of-concept (POC) test series. The report describes the performance of the tests and provides some preliminary performance data on particulate removal systems during the tests. The performance of ceramic tubes being tested for high temperature air heater application is described. Performance of advanced diagnostics equipment from both UTSI and MSU is summarized. The results of experiments designed to determine the effects of potassium compounds on combustion are included. Plans for analysis of metal tube specimens previously removed from the test train are discussed. Modeling and analysis of previous test data include a deposition model to predict ash deposition on tubes, mass balance results, automated data screening and chemical analyses and the data base containing these analyses. Laboratory tests on sealing ceramic tubes and corrosion analyses of previously tested tubes are reported.

Not Available

1993-12-01T23:59:59.000Z

240

Status of Proof-Of-Concept testing at the Coal-Fired-Flow Facility, 1993  

DOE Green Energy (OSTI)

Proof-of-concept (POC) testing, and collection and evaluation of data continued at the Coal-Fired-Flow Facility during the past year. Following four preliminary tests firing Rosebud coal in 1991 to establish base conditions for the Rosebud coal POC tests, three POC tests were run in 1992, and a fourth test early in 1993. Major equipment additions or modifications included installation of a wet electrostatic precipitator (ESP), which replaced a badly deteriorated venturi. This component also provides improved capability to meet Tennessee pollution regulations while operating the dry ESP and/or baghouse off design, or if one of these two control devices does not function properly. Improvements were also made to the dry ESP prior to the 1993 test, which appear to have improved the performance of this equipment. This paper will present an overview of the major results obtained during the Rosebud coal POC tests, including the performance of the dry and wet electrostatic precipitators. Differences between the Rosebud and Illinois coals will be described, but it is emphasized that these observations are based on incomplete results for the Rosebud coal.

Attig, R.C.; Chapman, J.N.; Johanson, N.R.

1993-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

OXIDATION OF MERCURY ACROSS SCR CATALYSTS IN COAL-FIRED POWER PLANTS BURING LOW RANK FUELS  

SciTech Connect

This is the sixth Quarterly Technical Report for DOE Cooperative Agreement No: DE-FC26-03NT41728. The objective of this program is to measure the oxidation of mercury in flue gas across SCR catalyst in a coal-fired power plant burning low rank fuels using a slipstream reactor containing multiple commercial catalysts in parallel. The Electric Power Research Institute (EPRI) and Argillon GmbH are providing co-funding for this program. This program contains multiple tasks and good progress is being made on all fronts. During this quarter, a review of the available data on mercury oxidation across SCR catalysts from small, laboratory-scale experiments, pilot-scale slipstream reactors and full-scale power plants was carried out. Data from small-scale reactors obtained with both simulated flue gas and actual coal combustion flue gas demonstrated the importance of temperature, ammonia, space velocity and chlorine on mercury oxidation across SCR catalyst. SCR catalysts are, under certain circumstances, capable of driving mercury speciation toward the gas-phase equilibrium values at SCR temperatures. Evidence suggests that mercury does not always reach equilibrium at the outlet. There may be other factors that become apparent as more data become available.

Constance Senior

2004-07-30T23:59:59.000Z

242

Using ISC & GIS to predict sulfur deposition from coal-fired power plants  

E-Print Network (OSTI)

The goal of this research project was to determine if atmospheric sources have the potential of contributing significantly to the sulfur content of grazed forage. Sulfur deposition resulting from sulfur dioxide emissions from coal- fired power plants was predicted utilizing the Industrial Source Complex Long-Term (ISCLT2) Model for the areas ofa interest in East Texas. GRASS, a geographical information system (GIS), was used to pull together all predicted values from ISCLT2 and present them in the form of predicted sulfur deposition maps with different ranges of deposition. Two field trips to NE Texas were taken to obtain data on soil and forage sulfur content. GRASS was used extensively in the planning process before each trip and the global positioning system was also used extensively during the trip to locate sampling sites and to obtain the geographical location of each site. The methodology developed predicts that 11 to 21 kg sulfur/ha per year can be deposited as far as 100 to 160 km from the source. Data from both field trips do not show a statistical significant relation between predicted sulfur deposition and either soil or forage sulfur content. However, the data do show that there is a trend of increasing soil and forage sulfur content as predicted sulfur deposition increases.

Lopez, Jose Ignacio

1993-01-01T23:59:59.000Z

243

An assessment of mercury emissions and health risks from a coal-fired power plant  

Science Conference Proceedings (OSTI)

Title 3 of the 1990 Clean Air Act Amendments (CAAA) mandated that the US Environmental Protection Agency (EPA) evaluate the need to regulate mercury emissions from electric utilities. In support of this forthcoming regulatory analysis the U.S. DOE, sponsored a risk assessment project at Brookhaven (BNL) to evaluate methylmercury (MeHg) hazards independently. In the US MeHg is the predominant way of exposure to mercury originated in the atmosphere. In the BNL study, health risks to adults resulting from Hg emissions from a hypothetical 1,000 MW coal-fired power plant were estimated using probabilistic risk assessment techniques. This study showed that the effects of emissions of a single power plant may double the background exposures to MeHg resulting from consuming fish obtained from a localized area near the power plant. Even at these more elevated exposure levels, the attributable incidence in mild neurological symptoms was estimated to be quite small, especially when compared with the estimated background incidence in the population. The current paper summarizes the basic conclusions of this assessment and highlights issues dealing with emissions control and environmental transport.

Fthenakis, V.M.; Lipfert, F.; Moskowitz, P. [Brookhaven National Lab., Upton, NY (United States). Analytical Sciences Div.

1994-12-01T23:59:59.000Z

244

Mercury capture within coal-fired power plant electrostatic precipitators: model evaluation  

Science Conference Proceedings (OSTI)

Efforts to reduce anthropogenic mercury emissions worldwide have recently focused on a variety of sources, including mercury emitted during coal combustion. Toward that end, much research has been ongoing seeking to develop new processes for reducing coal combustion mercury emissions. Among air pollution control processes that can be applied to coal-fired boilers, electrostatic precipitators (ESPs) are by far the most common, both on a global scale and among the principal countries of India, China, and the U.S. that burn coal for electric power generation. A previously reported theoretical model of in-flight mercury capture within ESPs is herein evaluated against data from a number of full-scale tests of activated carbon injection for mercury emissions control. By using the established particle size distribution of the activated carbon and actual or estimated values of its equilibrium mercury adsorption capacity, the incremental reduction in mercury concentration across each ESP can be predicted and compared to experimental results. Because the model does not incorporate kinetics associated with gas-phase mercury transformation or surface adsorption, the model predictions represent the mass-transfer-limited performance. Comparing field data to model results reveals many facilities performing at or near the predicted mass-transfer-limited maximum, particularly at low rates of sorbent injection. Where agreement is poor between field data and model predictions, additional chemical or physical phenomena may be responsible for reducing mercury removal efficiencies. 26 refs., 5 figs., 1 tab.

Clack, H.L. [Illinois Institute of Technology, Chicago, IL (United States). Department of Mechanical, Materials and Aerospace Engineering

2009-03-01T23:59:59.000Z

245

Development of a coal-fired gas turbine cogeneration system: Status report  

SciTech Connect

The Allison Advanced Coal-Fueled Turbine Program is now in the sixth year of a development effort that has led to a POC engine demonstration test on a Coal-Water-Slurry (CWS) fuel. Earlier forecasts by CWS suppliers that suitable CWS fuels would be commercially available at an economic price have not been realized. A program replan has, therefore, been executed that incorporates the use of readily available dry pulverized coal. To support this program, technology issues relating to combustor performance and emission control, hot gas cleanup, and turbine deposition, erosion and corrosion (DEC) have been addressed. In addition, system assessment studies have been performed to evaluate the commercial prospects for small (<8 MWe) coal-fired industrial cogeneration systems and the application of the rich-quench-lean (RQL) coal-combustion technology to larger (> 100 MWe) utility-sized gas turbines. These results are reported by Wenglarz (1992). Combustor and engine tests on dry coal are now planned in preparation for a commercial demonstration that will follow the completion of this program.

Wilkes, C.; Wenglarz, R.A.; Hart, P.J.; Thomas, W.H.; Rothrock, J.W.; Harris, C.N.; Bourke, R.C.

1992-01-01T23:59:59.000Z

246

Historical Costs of Coal-Fired Electricity and Implications for the Future  

E-Print Network (OSTI)

We study the costs of coal-fired electricity in the United States between 1882 and 2006 by decomposing it in terms of the price of coal, transportation costs, energy density, thermal efficiency, plant construction cost, interest rate, and capacity factor. The dominant determinants of costs at present are the price of coal and plant construction cost. The price of coal appears to fluctuate more or less randomly while the construction cost follows long-term trends, decreasing from 1902 - 1970, increasing from 1970 - 1990, and leveling off or decreasing a little since then. This leads us to forecast that even without carbon capture and storage, and even under an optimistic scenario in which construction costs resume their previously decreasing trending behavior, the cost of coal-based electricity will drop for a while but eventually be determined by the price of coal, which varies stochastically but shows no long term decreasing trends. Our analysis emphasizes the importance of using long time series and compari...

McNerney, James; Farmer, J Doyne

2010-01-01T23:59:59.000Z

247

Southern thailand coal fired project: Conceptual design. Volume 1. Export trade information  

SciTech Connect

The report addresses various technical, environmental, and economic aspects of developing four 1,000 MW units of coal fired electric generating facilities at a site near Prachuap Khiri Khan. The study includes a cost estimate for the units and the fuel delivery port as well as the major conceptual design decisions made for the project. The study is accompanied by four Conceptual Design manuals. The manual was prepared to communicate project design parameters and requirements to participants of the project, and to control uniformity of design concepts throughout the project. This is Volume 1 of the Conceptual Design and is divided into the following sections: (1) Project Descirption; (2) Site Investigations; (3) Permits and Licenses; (4) Site Planning and Information; (5) Meteorology; (6) Generation Plant Planning; (7) Generatioin Plant Information; (8) Economic Criteria; (9) System Design; (10) Structural Engineering Design Criteria; (11) Mechanical Engineering Design Criteria; (12) Electrical Engineering Design Criteria; (13) Control Engineering Design Criteria; (14) Chemical Engineering Design Criteria; (15) Equipment Nomenclature and Numbering.

1995-09-01T23:59:59.000Z

248

CFCC Development Program. Commercial plant reliability and maintainability evaluation (Task 1. 4). [Coal-fired  

SciTech Connect

The Coal Fired Combined Cycle (CFCC) is the unique powerplant concept developed under the leadership of the General Electric Company to provide a direct coal-burning gas turbine and steam turbine combined cycle powerplant. The advantages of the combined cycle for higher efficiency and the potential of the pressurized fluidized bed (PFB) combustor for improvements in emissions could offer a new and attractive option to the electric utility industry, after its successful development. The CFCC approach provides cooling of the fluid bed combustor through the use of steam tubes in the bed, which supply a steam turbine-generator. The partially cooled combustion gases exiting from the combustor drive a gas turbine-generator after passing through a hot-gas cleanup train. On the basis of previous studies and confirming work under this contract, General Electric continues to believe that the CFCC approach offers important advantages over alternate approaches: higher powerplant efficiency in the combustor temperature range of interest; reduced combustor/steam generator corrosion potential, due to low fluid-bed tube temperature (as contrasted to the air in tube cycle); reduced hot-gas cleanup flow rate (as contrasted with the uncooled combustor cycle); and increased gas turbine bucket life from improved material protection systems. The present report involves mainly a failure mode analysis for components of the plant.

1978-10-01T23:59:59.000Z

249

Should a coal-fired power plant be replaced or retrofitted?  

SciTech Connect

In a cap-and-trade system, a power plant operator can choose to operate while paying for the necessary emissions allowances, retrofit emissions controls to the plant, or replace the unit with a new plant. Allowance prices are uncertain, as are the timing and stringency of requirements for control of mercury and carbon emissions. We model the evolution of allowance prices for SO{sub 2}, NOx, Hg, and CO{sub 2} using geometric Brownian motion with drift, volatility, and jumps, and use an options-based analysis to find the value of the alternatives. In the absence of a carbon price, only if the owners have a planning horizon longer than 30 years would they replace a conventional coal-fired plant with a high-performance unit such as a supercritical plant; otherwise, they would install SO{sub 2} and NOx controls on the existing unit. An expectation that the CO{sub 2} price will reach $50/t in 2020 makes the installation of an IGCC with carbon capture and sequestration attractive today, even for planning horizons as short as 20 years. A carbon price below $40/t is unlikely to produce investments in carbon capture for electric power. 1 ref., 5 figs., 2 tabs.

Dalia Patino-Echeverri; Benoit Morel; Jay Apt; Chao Chen [Carnegie Mellon University, Pittsburgh, PA (USA)

2007-12-15T23:59:59.000Z

250

Mercury Speciation in Coal-Fired Power Plant Flue Gas-Experimental Studies and Model Development  

SciTech Connect

The overall goal of the project was to obtain a fundamental understanding of the catalytic reactions that are promoted by solid surfaces present in coal combustion systems and develop a mathematical model that described key phenomena responsible for the fate of mercury in coal-combustion systems. This objective was achieved by carefully combining laboratory studies under realistic process conditions using simulated flue gas with mathematical modeling efforts. Laboratory-scale studies were performed to understand the fundamental aspects of chemical reactions between flue gas constituents and solid surfaces present in the fly ash and their impact on mercury speciation. Process models were developed to account for heterogeneous reactions because of the presence of fly ash as well as the deliberate addition of particles to promote Hg oxidation and adsorption. Quantum modeling was used to obtain estimates of the kinetics of heterogeneous reactions. Based on the initial findings of this study, additional work was performed to ascertain the potential of using inexpensive inorganic sorbents to control mercury emissions from coal-fired power plants without adverse impact on the salability fly ash, which is one of the major drawbacks of current control technologies based on activated carbon.

Radisav Vidic; Joseph Flora; Eric Borguet

2008-12-31T23:59:59.000Z

251

Development of a coal fired pulse combustor for residential space heating. Phase I, Final report  

SciTech Connect

This report presents the results of the first phase of a program for the development of a coal-fired residential combustion system. This phase consisted of the design, fabrication, testing, and evaluation of an advanced pulse combustor sized for residential space heating requirements. The objective was to develop an advanced pulse coal combustor at the {approximately} 100,000 Btu/hr scale that can be integrated into a packaged space heating system for small residential applications. The strategy for the development effort included the scale down of the feasibility unit from 1-2 MMBtu/hr to 100,000 Btu/hr to establish a baseline for isolating the effect of scale-down and new chamber configurations separately. Initial focus at the residential scale was concentrated on methods of fuel injection and atomization in a bare metal unit. This was followed by incorporating changes to the advanced chamber designs and testing of refractory-lined units. Multi-fuel capability for firing oil or gas as a secondary fuel was also established. Upon completion of the configuration and component testing, an optimum configuration would be selected for integrated testing of the pulse combustor unit. The strategy also defined the use of Dry Ultrafine Coal (DUC) for Phases 1 and 2 of the development program with CWM firing to be a product improvement activity for a later phase of the program.

NONE

1988-04-01T23:59:59.000Z

252

Multiplexed Optical Fiber Sensors for Coal Fired Advanced Fossil Energy Systems  

Science Conference Proceedings (OSTI)

This report summarizes technical progress on the program ??Multiplexed Optical Fiber Sensors for Coal Fired Advanced Fossil Energy Systems? funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed jointly by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering and the Department of Materials Science and Engineering at Virginia Tech. This three-year project started on October 1, 2008. In the project, a fiber optical sensing system based on intrinsic Fabry-Perot Interferometer (IFPI) was developed for strain and temperature measurements for Ultra Supercritical boiler condition assessment. Investigations were focused on sensor design, fabrication, attachment techniques and novel materials for high temperature and strain measurements. At the start of the project, the technical requirements for the sensing technology were determined together with our industrial partner Alstom Power. As is demonstrated in Chapter 4, all the technical requirements are successfully met. The success of the technology extended beyond laboratory test; its capability was further validated through the field test at DOE NETL, in which the sensors yielded distributed temperature mapping of a testing coupon installed in the turbine test rig. The measurement results agreed well with prior results generated with thermocouples. In this project, significant improvements were made to the IFPI sensor technology by splicing condition optimization, transmission loss reduction, sensor signal demodulation and sensor system design.

Anbo Wang; Gary Pickrell

2011-12-31T23:59:59.000Z

253

NNSA Acting Administrator Bruce Held holds all hands meeting...  

NLE Websites -- All DOE Office Websites (Extended Search)

NNSA Acting Administrator Bruce Held holds all hands meeting | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the...

254

Bruce, South Dakota: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Page Edit with form History Share this page on Facebook icon Twitter icon Bruce, South Dakota: Energy Resources Jump to: navigation, search Equivalent URI DBpedia...

255

EVALUATION OF MERCURY EMISSIONS FROM COAL-FIRED FACILITIES WITH SCR AND FGD SYSTEMS  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), evaluated the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP)-wet flue gas desulfurization (FGD) combination or a spray dyer absorber-fabric filter (SDA-FF) combination. In this program CONSOL determined mercury speciation and removal at 10 bituminous coal-fired facilities; at four of these facilities, additional tests were performed on units without SCR, or with the existing SCR bypassed. This project final report summarizes the results and discusses the findings of the body of work as a whole. Eleven Topical Reports were issued (prior to this report) that describe in great detail the sampling results at each of the ten power plants individually. The results showed that the SCR-FGD combination removed a substantial fraction of mercury from flue gas. The coal-to-stack mercury removals ranged from 65% to 97% for the units with SCR and from 53% to 87% for the units without SCR. There was no indication that any type of FGD system was more effective at mercury removal than others. The coal-to-stack mercury removal and the removal in the wet scrubber were both negatively correlated with the elemental mercury content of the flue gas and positively correlated with the scrubber liquid chloride concentration. The coal chlorine content was not a statistically significant factor in either case. Mercury removal in the ESP was positively correlated with the fly ash carbon content and negatively correlated with the flue gas temperature. At most of the units, a substantial fraction (>35%) of the flue gas mercury was in the elemental form at the boiler economizer outlet. After passing through the SCR-air heater combination very little of the total mercury (<10%) remained in the elemental form in the flue gas; this was true for all SCR catalyst types and sources. Although chlorine has been suggested as a factor affecting the mercury speciation in flue gas, coal chlorine was not a statistically significant factor affecting mercury speciation at the economizer exit or at the air heater exit. The only statistically significant factors were the coal ash CaO content and the fly ash carbon content; the fraction of mercury in the elemental form at the economizer exit was positively correlated with both factors. In a direct comparison at four SCR-equipped units vs. similar units at the same sites without SCR (or with the SCR bypassed), the elemental mercury fractions (measured at the ESP outlet) were lower, and the coal-to-stack mercury removals were higher, when the SCR was present and operating. The average coal-to-stack mercury removal at the four units without an operating SCR was 72%, whereas the average removal at the same sites with operating SCRs was 88%. The unit mercury mass balance (a gauge of the overall quality of the tests) at all of the units ranged from 81% to 113%, which were within our QA/QC criterion of 80-120%.

J.A. Withum

2006-03-07T23:59:59.000Z

256

Characterization of Oxy-combustion Impacts in Existing Coal-fired Boilers  

Science Conference Proceedings (OSTI)

Reaction Engineering International (REI) managed a team of experts from University of Utah, Siemens Energy, Praxair, Vattenfall AB, Sandia National Laboratories, Brigham Young University (BYU) and Corrosion Management Ltd. to perform multi-scale experiments, coupled with mechanism development, process modeling and CFD modeling, for both applied and fundamental investigations. The primary objective of this program was to acquire data and develop tools to characterize and predict impacts of CO2 flue gas recycle and burner feed design on flame characteristics (burnout, NOx, SOx, mercury and fine particle emissions, heat transfer) and operational concerns (fouling, slagging and corrosion) inherent in the retrofit of existing coal-fired boilers for oxy-coal combustion. Experimental work was conducted at Sandia National Laboratories Entrained Flow Reactor, the University of Utah Industrial Combustion Research Facility, and Brigham Young University. Process modeling and computational fluid dynamics (CFD) modeling was performed at REI. Successful completion of the project objectives resulted in the following key deliverables: 1) Multi-scale test data from 0.1 kW bench-scale, 100 kW and 200 kW laboratory-scale, and 1 MW semi-industrial scale combustors that describe differences in flame characteristics, fouling, slagging and corrosion for coal combustion under air-firing and oxygen-firing conditions, including sensitivity to oxy-burner design and flue gas recycle composition. 2) Validated mechanisms developed from test data that describe fouling, slagging, waterwall corrosion, heat transfer, char burnout and sooting under coal oxy-combustion conditions. The mechanisms were presented in a form suitable for inclusion in CFD models or process models. 3) Principles to guide design of pilot-scale and full-scale coal oxy-firing systems and flue gas recycle configurations, such that boiler operational impacts from oxy-combustion retrofits are minimized. 4) Assessment of oxy-combustion impacts in two full-scale coal-fired utility boiler retrofits based on computational fluid dynamics (CFD) modeling of air-fired and oxygen-fired operation. This research determined that it is technically feasible to retrofit the combustion system in an air-fired boiler for oxy-fired operation. The impacts of CO2 flue gas recycle and burner design on flame characteristics (burnout, NOx, SOx, mercury and fine particle emissions, heat transfer) and operational concerns (fouling, slagging and corrosion) were minimal, with the exception of high sulfur levels resulting from untreated flue gas recycle with medium and high-sulfur coals. This work focused on combustion in the radiant and convective sections of the boiler and did not address boiler system integration issues, plant efficiencies, impacts on downstream air pollution control devices, or CO2 capture and compression. The experimental data, oxy-firing system principles and oxy-combustion process mechanisms provided by this work can be used by electric utilities, boiler OEMs, equipment suppliers, design firms, software vendors, consultants and government agencies to assess retrofit applications of oxy-combustion technologies to existing boilers and to guide development of new designs.

Adams, Bradley; Davis, Kevin; Senior, Constance; Shim, Hong Shim; Otten, Brydger; Fry, Andrew; Wendt, Jost; Eddings, Eric; Paschedag, Alan; Shaddix, Christopher; Cox, William; Tree, Dale

2013-09-30T23:59:59.000Z

257

Pollution control and environmental monitoring efforts at DOE's Coal-Fired Flow Facility  

DOE Green Energy (OSTI)

Proof-of-Concept (POC) scale demonstration of such technology is currently being carried out at the US Department of Energy's (DOE's) Coal-Fired Flow Facility (CFFF), located at The University of Tennessee Space Institute (UTSI) in Tullahoma, Tennessee and at the Component Development and Integration Facility in Butte, Montana. The CFFF is dedicated to the evaluation of downstream (steam cycle) components and technology that may be considered for a full-scale MHD system. The objectives of the CFFF testing include the demonstration of various pollution control devices and techniques at a scale sufficient for future scale-up. The CFFF offers a unique test environment in which emissions control techniques can be developed and evaluated through emissions and environmental monitoring. Results thus far have demonstrated the ability of sulfur oxide (SO{sub x}), nitrogen oxide (NO{sub x}) and particulate emissions well below the New Source Performance Standards (NSPS). Regeneration of the potassium sulfate to produce sulfur-free compounds also has been demonstrated. The experimental program at the CFFF is now aimed at determining the optimum conditions for future commercial scale designs. Because of increased interests in Air Toxics, measurements of nitrous oxide (N{sub 2}O), a potential greenhouse gas, priority pollutants (inorganic as well as organics), and chlorine-containing species (Cl{sub 2} and HCl) are also included in our ongoing efforts. Environmental monitoring activities are being pursued to develop an environmental impact assessment data base. These include the use of three ambient air sites to determine the impacts of gaseous and particulate emissions, five lake water sites to determine impacts due to process water discharges and seven sites to collect terrestrial data on possible soil contamination and tree growth. In this paper, we will summarize the status of our ongoing environmental program. 16 refs., 15 figs., 3 tabs.

Attig, R.C.; Crawford, L.W.; Lynch, T.P.; Sheth, A.C.

1991-01-01T23:59:59.000Z

258

OXIDATION OF MERCURY ACROSS SCR CATALYSTS IN COAL-FIRED POWER PLANTS BURNING LOW RANK FUELS  

SciTech Connect

This is the third Quarterly Technical Report for DOE Cooperative Agreement No: DE-FC26-03NT41728. The objective of this program is to measure the oxidation of mercury in flue gas across SCR catalyst in a coal-fired power plant burning low rank fuels using a slipstream reactor containing multiple commercial catalysts in parallel. The Electric Power Research Institute (EPRI) and Argillon GmbH are providing co-funding for this program. This program contains multiple tasks and good progress is being made on all fronts. During this quarter, the second set of mercury measurements was made after the catalysts had been exposed to flue gas for about 2,000 hours. There was good agreement between the Ontario Hydro measurements and the SCEM measurements. Carbon trap measurements of total mercury agreed fairly well with the SCEM. There did appear to be some loss of mercury in the sampling system toward the end of the sampling campaign. NO{sub x} reductions across the catalysts ranged from 60% to 88%. Loss of total mercury across the commercial catalysts was not observed, as it had been in the March/April test series. It is not clear whether this was due to aging of the catalyst or to changes in the sampling system made between March/April and August. In the presence of ammonia, the blank monolith showed no oxidation. Two of the commercial catalysts showed mercury oxidation that was comparable to that in the March/April series. The other three commercial catalysts showed a decrease in mercury oxidation relative to the March/April series. Oxidation of mercury increased without ammonia present. Transient experiments showed that when ammonia was turned on, mercury appeared to desorb from the catalyst, suggesting displacement of adsorbed mercury by the ammonia.

Constance Senior; Temi Linjewile

2003-10-31T23:59:59.000Z

259

Engineering Development of Coal-Fired High-Performance Power Systems  

Science Conference Proceedings (OSTI)

A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolysis process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas turbine air is indirectly heated. The fuel gas generated in the pyrolyzer is then used to heat the gas turbine air further before it enters the gas turbine. The project is currently in Phase 2 which includes engineering analysis, laboratory testing and pilot plant testing. Research and development is being done on the HIPPS systems that are not commercial or being developed on other projects. Pilot plant testing of the pyrolyzer subsystem and the char combustion subsystem are being done separately. This report addresses the areas of technical progress for this quarter. The detail of syngas cooler design is given in this report. The final construction work of the CFB pyrolyzer pilot plant has started during this quarter. No experimental testing was performed during this quarter. The proposed test matrix for the future CFB pyrolyzer tests is given in this report. Besides testing various fuels, bed temperature will be the primary test parameter.

York Tsuo

2000-12-31T23:59:59.000Z

260

Optimization of Trona/Limestone Injection for SO2 Control in Coal-Fired Boilers  

SciTech Connect

Mobotec USA develops and markets air pollution control systems for utility boilers and other combustion systems. They have a particular interest in technologies that can reduce NOx, SOx, and mercury emissions from coal-fired boilers, and have been investigating the injection of sorbents such as limestone and trona into a boiler to reduce SOx and Hg emissions. WRI proposed to use the Combustion Test Facility (CTF) to enable Mobotec to conduct a thorough evaluation of limestone and trona injection for SO{sub 2} control. The overall goal of the project was to characterize the SO{sub 2} reductions resulting from the injection of limestone and trona into the CTF when fired with a high-sulfur eastern bituminous coal used in one of Mobotec's Midwest installations. Results revealed that when limestone was injected at Ca:S molar ratios of 1.5 to 3.0, the resulting SO{sub 2} reductions were 35-55%. It is believed that further reductions can be attained with improved mixing of the sorbent with the combustion gases. When limestone was added to the coal, at Ca:S molar ratios of 0.5 to 1.5, the SO{sub 2} reductions were 13-21%. The lower reductions were attributed to dead-burning of the sorbent in the high temperature flame zone. In cases where limestone was both injected into the furnace and added to the coal, the total SO{sub 2} reductions for a given Ca:S molar ratio were similar to the reductions for furnace injection only. The injection of trona into the mid-furnace zone, for Na:S molar ratios of 1.4 to 2.4, resulted in SO{sub 2} reductions of 29-43%. Limestone injection did not produce any slag deposits on an ash deposition probe while trona injection resulted in noticeable slag deposition.

None

2005-09-01T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Coal-fired high performance power generating system. Quarterly progress report  

SciTech Connect

The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of > 47% thermal efficiency; NO{sub x} SO {sub x} and Particulates < 25% NSPS; Cost of electricity 10% lower; coal > 65% of heat input and all solid wastes benign. In order to achieve these goals our team has outlined a research plan based on an optimized analysis of a 250 MW{sub e} combined cycle system applicable to both frame type and aeroderivative gas turbines. Under the constraints of the cycle analysis we have designed a high temperature advanced furnace (HITAF) which integrates several combustor and air heater designs with appropriate ash management procedures. Most of this report discusses the details of work on these components, and the R&D Plan for future work. The discussion of the combustor designs illustrates how detailed modeling can be an effective tool to estimate NO{sub x} production, minimum burnout lengths, combustion temperatures and even particulate impact on the combustor walls. When our model is applied to the long flame concept it indicates that fuel bound nitrogen will limit the range of coals that can use this approach. For high nitrogen coals a rapid mixing, rich-lean, deep staging combustor will be necessary. The air heater design has evolved into two segments: a convective heat exchanger downstream of the combustion process; a radiant panel heat exchanger, located in the combustor walls; The relative amount of heat transferred either radiatively or convectively will depend on the combustor type and the ash properties.

Not Available

1992-07-01T23:59:59.000Z

262

Coal-fired high performance power generating system. Quarterly progress report  

Science Conference Proceedings (OSTI)

The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of > 47% thermal efficiency; NO{sub x} SO {sub x} and Particulates 65% of heat input and all solid wastes benign. In order to achieve these goals our team has outlined a research plan based on an optimized analysis of a 250 MW{sub e} combined cycle system applicable to both frame type and aeroderivative gas turbines. Under the constraints of the cycle analysis we have designed a high temperature advanced furnace (HITAF) which integrates several combustor and air heater designs with appropriate ash management procedures. Most of this report discusses the details of work on these components, and the R&D Plan for future work. The discussion of the combustor designs illustrates how detailed modeling can be an effective tool to estimate NO{sub x} production, minimum burnout lengths, combustion temperatures and even particulate impact on the combustor walls. When our model is applied to the long flame concept it indicates that fuel bound nitrogen will limit the range of coals that can use this approach. For high nitrogen coals a rapid mixing, rich-lean, deep staging combustor will be necessary. The air heater design has evolved into two segments: a convective heat exchanger downstream of the combustion process; a radiant panel heat exchanger, located in the combustor walls; The relative amount of heat transferred either radiatively or convectively will depend on the combustor type and the ash properties.

Not Available

1992-07-01T23:59:59.000Z

263

Rethinking the scale of coal-fired electric generation: technological and institutional considerations  

SciTech Connect

This paper examines the economic and social implications of an electric-utility system based on medium-scale (50 to 200 MWe) coal-fired plants dispersed near load centers. The historical trend in US electric generation has been a sustained effort to capture the economies of large scale. Technical and institutional conditions within the industry, as well as the historical perception of universal electrification as a desirable social goal, have brought about this trend. Large fossil and nuclear plants, often representing joint ventures of several utilities, dominate the plans of utilities over the next 20 years. Despite these trends, this review was unable to conclude that clear advantages must inherently accrue to either small- or large-scale electrical generation. Transportation and construction do offer demonstrable economies of scale, but the other terms in the cost equation (such as reliability and transmission) are sufficiently uncertain or site-specific to prevent firm conclusions concerning the effect of scale. Biases believed to exist in the regulatory process would dilute the utilities' perception of any advantages accruing to small generators; rate-of-return regulation favors overcapitalization as embodied in the construction of large plants and extensive transmission networks. It is not clear that the current regulatory structure is capable of weighing the institutional values of accountability and local control against dollar savings generally supposed to accrue to large plants. The Midwest and East North Central states may be singularly fit for a decentralized, medium-scale system for historical, geographical, and institutional reasons, as well as for their location near the coal fields.

Gilmer, R.W.; Meunier, R.E.; Whittle, C.E.

1978-04-01T23:59:59.000Z

264

Continuous Measurement Technologies for SO3 and H2SO4 in Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

The use of selective catalytic reduction (SCR) technology to reduce emissions of nitrogen oxides (NOx) from coal-fired power plants can result in the oxidation of sulfur dioxide (SO2) in the flue gas to sulfur trioxide (SO3) with a number of undesirable consequences, including the emission of acid aerosols from the stack leading to a visible plume. Injected additives can control SO3, but no method is currently available to continuously monitor SO3 and make it possible to optimize additive use. This repor...

2004-09-29T23:59:59.000Z

265

Multimedia Fate of Selenium and Boron at Coal-Fired Power Plants Equipped with Particulate and Wet FGD Controls  

Science Conference Proceedings (OSTI)

Given the current regulatory climate in the United States, a number of flue gas desulfurization (FGD) systemsas well as selective catalytic reduction (SCR) systemswill be installed at new and existing coal-fired power plants to remove sulfur dioxide (SO2) and nitrogen oxide (NOx). The multimedia fate of trace metals species in SCR/wet FGD systems is not well understood. Understanding and quantifying the amount of trace elements removed from the flue gas and distributed to the solid and aqueous streams is...

2008-12-19T23:59:59.000Z

266

Experimental results of the UTSI coal-fired MHD generator and investigations of various power take-off schemes  

SciTech Connect

Tests were conducted at The University of Tennessee Space Institute, Energy Conversion Division, in support of technology development of coal-fired magnetohydrodynamic (MHD) generator systems. The primary objectives of the test series were to evaluate the overall electrical performance of the 60/degree/ DCW generator with vitation heated oxidizer, to study the thermal behavior of capped versus solid frame electrodes, and to investigate various power take-off schemes. Results from the above-mentioned areas of investigation are presented and discussed. 13 refs.

Galanga, F.L.; Lineberry, J.L.; Wu, Y.C.L.; Scott, M.H.; Baucum, W.E.; Clemons, R.W.

1981-01-01T23:59:59.000Z

267

Evaluation of Solid Sorbents as a Retrofit Technology for CO2 Capture from Coal-Fired Power Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

Solid Sorbents as a Solid Sorbents as a Retrofit Technology for CO 2 Capture from Coal-fired Power Plants Background Retrofitting the current fleet of pulverized coal (PC)-fired power plants for the separation and sequestration of carbon dioxide (CO 2 ) is one of the most significant challenges for effective, long-term carbon management. Post-combustion CO 2 capture using solid-sorbent based technologies is a potential resolution to this challenge that could be appropriate for both new and existing PC-fired power plant

268

Engineering development of advanced coal-fired low-emission boiler system. Technical progress report No. 1, August--December 1992  

Science Conference Proceedings (OSTI)

The Pittsburgh Energy Technology Center of the US Department of Energy (DOE) has contracted with Combustion Engineering, Inc. (ABB CE) to perform work on the ``Engineering Development of Advanced Coal-Fired Low-Emission Boiler Systems`` Project and has authorized ABB CE to complete Phase I on a cost-reimbursable basis. The overall objective of the Project is the expedited commercialization of advanced coal-fired low-emission boiler systems. The specified primary objectives are: NO{sub x} emissions not greater than one-third NSPS; SO{sub x} emissions not greater than one-third NSPS; and particulate emissions not greater than one-half NSPS. The specific secondary objectives are: Improved ash disposability and reduced waste generation; reduced air toxics emissions; increased generating efficiency. The final deliverables are a design data base that will allow future coal-fired power plants to meet the stated objectives and a preliminary design of a commercial generation unit.

Not Available

1993-02-26T23:59:59.000Z

269

Particle Formation and Growth in Power Plant Plumes, Volume 1: Field Observations and Theoretical Studies of the Evolution of Partic les in the Plumes from Coal-Fired Electric Power Plants  

Science Conference Proceedings (OSTI)

Volume 1 of this report describes parallel field and theoretical studies of particle-size distributions in the plumes of coal-fired power plants.Volume 2 presents measurements of concentration of particulate sulfur, sulfate, nitrate, total particulate volume.Aitken nuclei, and various trace gases in the plumes of six coal-fired power plants.

1983-05-01T23:59:59.000Z

270

The ADESORB Process for Economical Production of Sorbents for Mercury Removal from Coal Fired Power Plants  

SciTech Connect

The DOE's National Energy Technology Laboratory (NETL) currently manages the largest research program in the country for controlling coal-based mercury emissions. NETL has shown through various field test programs that the determination of cost-effective mercury control strategies is complex and highly coal- and plant-specific. However, one particular technology has the potential for widespread application: the injection of activated carbon upstream of either an electrostatic precipitator (ESP) or a fabric filter baghouse. This technology has potential application to the control of mercury emissions on all coal-fired power plants, even those with wet and dry scrubbers. This is a low capital cost technology in which the largest cost element is the cost of sorbents. Therefore, the obvious solutions for reducing the costs of mercury control must focus on either reducing the amount of sorbent needed or decreasing the cost of sorbent production. NETL has researched the economics and performance of novel sorbents and determined that there are alternatives to the commercial standard (NORIT DARCO{reg_sign} Hg) and that this is an area where significant technical improvements can still be made. In addition, a key barrier to the application of sorbent injection technology to the power industry is the availability of activated carbon production. Currently, about 450 million pounds ($250 million per year) of activated carbon is produced and used in the U.S. each year - primarily for purification of drinking water, food, and beverages. If activated carbon technology were to be applied to all 1,100 power plants, EPA and DOE estimate that it would require an additional $1-$2 billion per year, which would require increasing current capacity by a factor of two to eight. A new facility to produce activated carbon would cost approximately $250 million, would increase current U.S. production by nearly 25%, and could take four to five years to build. This means that there could be significant shortages in supply if response to new demand is not well-timed.

Robin Stewart

2008-03-12T23:59:59.000Z

271

Mercury emission control for coal fired power plants using coal and biomass  

E-Print Network (OSTI)

Mercury is a leading concern among the air toxic metals addressed in the 1990 Clean Air Act Amendments (CAAA) because of its volatility, persistence, and bioaccumulation as methylmercury in the environment and its neurological health impacts. The Environmental Protection Agency (EPA) reports for 2001 shows that total mercury emissions from all sources in USA is about 145 tons per annum, of which coal fired power plants contribute around 33% of it, about 48 tons per annum. Unlike other trace metals that are emitted in particulate form, mercury is released in vapor phase in elemental (Hg0) or oxidized (Hg2+, mainly HgCl2) form. To date, there is no post combustion treatment which can effectively capture elemental mercury vapor, but the oxidized form of mercury can be captured in traditional emission control devices such as wet flue gas defulrization (WFGD) units, since oxidized mercury (HgCl2) is soluble in water. The chlorine concentration present during coal combustion plays a major role in mercury oxidation, which is evident from the fact that plants burning coal having high chlorine content have less elemental mercury emissions. A novel method of co-firing blends of low chlorine content coal with high chlorine content cattle manure/biomass was used in order to study its effect on mercury oxidation. For Texas Lignite and Wyoming coal the concentrations of chlorine are 139 ppm and 309 ppm on dry ash free basis, while for Low Ash Partially Composted Dairy Biomass it is 2,691 ppm. Co-firing experiments were performed in a 100,000 BTU/hr (29.3 kWt) Boiler Burner facility located in the Coal and Biomass Energy laboratory (CBEL); coal and biomass blends in proportions of 80:20, 90:10, 95:5 and 100:0 were investigated as fuels. The percentage reduction of Hg with 95:5, 90:10 and 80:20 blends were measured to be 28- 50%, 42-62% and 71-75% respectively. Though cattle biomass serves as an additive to coal, to increase the chlorine concentration, it leads to higher ash loading. Low Ash and High Ash Partially Composted Dairy Biomass have 164% and 962% more ash than Wyoming coal respectively. As the fraction of cattle biomass in blend increases in proportion, ash loading problems increase simultaneously. An optimum blend ratio is arrived and suggested as 90:10 blend with good reduction in mercury emissions without any compromise on ash loading.

Arcot Vijayasarathy, Udayasarathy

2007-12-01T23:59:59.000Z

272

OXIDATION OF MERCURY ACROSS SCR CATALYSTS IN COAL-FIRED POWER PLANTS BURNING LOW RANK FUELS  

SciTech Connect

The objectives of this program were to measure the oxidation of mercury in flue gas across SCR catalyst in a coal-fired power plant burning low rank fuels using a slipstream reactor containing multiple commercial catalysts in parallel and to develop a greater understanding of mercury oxidation across SCR catalysts in the form of a simple model. The Electric Power Research Institute (EPRI) and Argillon GmbH provided co-funding for this program. REI used a multicatalyst slipstream reactor to determine oxidation of mercury across five commercial SCR catalysts at a power plant that burned a blend of 87% subbituminous coal and 13% bituminous coal. The chlorine content of the blend was 100 to 240 {micro}g/g on a dry basis. Mercury measurements were carried out when the catalysts were relatively new, corresponding to about 300 hours of operation and again after 2,200 hours of operation. NO{sub x}, O{sub 2} and gaseous mercury speciation at the inlet and at the outlet of each catalyst chamber were measured. In general, the catalysts all appeared capable of achieving about 90% NO{sub x} reduction at a space velocity of 3,000 hr{sup -1} when new, which is typical of full-scale installations; after 2,200 hours exposure to flue gas, some of the catalysts appeared to lose NO{sub x} activity. For the fresh commercial catalysts, oxidation of mercury was in the range of 25% to 65% at typical full-scale space velocities. A blank monolith showed no oxidation of mercury under any conditions. All catalysts showed higher mercury oxidation without ammonia, consistent with full-scale measurements. After exposure to flue gas for 2,200 hours, some of the catalysts showed reduced levels of mercury oxidation relative to the initial levels of oxidation. A model of Hg oxidation across SCRs was formulated based on full-scale data. The model took into account the effects of temperature, space velocity, catalyst type and HCl concentration in the flue gas.

Constance Senior

2004-12-31T23:59:59.000Z

273

Engineering Development of Coal-Fired High-Performance Power Systems  

SciTech Connect

A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolysis process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas turbine air is indirectly heated. The fuel gas generated in the pyrolyzer is then used to heat the gas turbine air further before it enters the gas turbine. The project is currently in Phase 2 which includes engineering analysis, laboratory testing and pilot plant testing. Research and development is being done on the HIPPS systems that are not commercial or being developed on other projects. Pilot plant testing of the pyrolyzer subsystem and the char combustion subsystem are being done separately, and after each experimental program has been completed, a larger scale pyrolyzer will be tested at the Power Systems Development Facility (PSDF) in Wilsonville, AL. The facility is equipped with a gas turbine and a topping combustor, and as such, will provide an opportunity to evaluate integrated pyrolyzer and turbine operation. This report addresses the areas of technical progress for this quarter. Detailed design of the components to be used to for the circulating bed gasification tests is underway. The circulating fluidized bed will allow for easy scale-up to larger size plants. The existing pyrolyzer will be outfitted with a cyclone and a j-valve to capture and reinject char into the lower combustion zone. Additional development work has been performed to evaluate advanced cycles utilizing the HIPPS system concept.

York Tsuo

1999-12-31T23:59:59.000Z

274

ENGINEERING DEVELOPMENT OF COAL-FIRED HIGH-PERFORMANCE POWER SYSTEMS  

SciTech Connect

A High Performance Power System (HIPPS) is being developed. This system is a coal-fired, combined cycle plant with indirect heating of gas turbine air. Foster Wheeler Development Corporation and a team consisting of Foster Wheeler Energy Corporation, Bechtel Corporation, University of Tennessee Space Institute and Westinghouse Electric Corporation are developing this system. In Phase 1 of the project, a conceptual design of a commercial plant was developed. Technical and economic analyses indicated that the plant would meet the goals of the project which include a 47 percent efficiency (HHV) and a 10 percent lower cost of electricity than an equivalent size PC plant. The concept uses a pyrolyzation process to convert coal into fuel gas and char. The char is fired in a High Temperature Advanced Furnace (HITAF). The HITAF is a pulverized fuel-fired boiler/air heater where steam is generated and gas turbine air is indirectly heated. The fuel gas generated in the pyrolyzer is then used to heat the gas turbine air further before it enters the gas turbine. The project is currently in Phase 2, which includes engineering analysis, laboratory testing and pilot plant testing. Research and development is being done on the HIPPS systems that are not commercial or being developed on other projects. Pilot plant testing of the pyrolyzer subsystem and the char combustion subsystem are being done separately, and after each experimental program has been completed, a larger scale pyrolyzer will be tested at the Power Systems Development Facility (PSDF) in Wilsonville, AL. The facility is equipped with a gas turbine and a topping combustor, and as such, will provide an opportunity to evaluate integrated pyrolyzer and turbine operation. This report addresses the areas of technical progress for this quarter. In order to prepare the CETF for the HIPPS char combustion test program, the following three subsystems were designed during this quarter: (1) Flue Gas Recycle System; (2) Pulverized Coal Feed System; and (3) Limestone Feed System The flue gas recycle system is added to simulate the performance of a commercial char burner fired with gas turbine exhaust. Since synthetically made char will be used for the tests at the CETF, the limestone injection system was added to produce a char more representative of that from an actual pyrolyzer. The pulverized coal system is included to provide a supplemental support fuel if a stable flame can not be maintained with char firing only.

1998-10-01T23:59:59.000Z

275

Updated Hazardous Air Pollutants (HAPs) Emissions Estimates and Inhalation Human Health Risk Assessment for U.S. Coal-Fired Electric Generating Units  

Science Conference Proceedings (OSTI)

Since the mid-1990s, there has been no comprehensive evaluation of hazardous air pollutants (HAPs) emissions from U.S. coal-fired electric power plants and the risks associated with those emissions. With the exception of mercury, none of the HAPs-classified chemicals has been fundamentally reassessed for more than 15 years. The set of EPRI studies reported on here provides a fundamental reevaluation of potential HAPs emissions from coal-fired power plants based on current data concerning coals burned, co...

2009-12-28T23:59:59.000Z

276

Characterization of open-cycle coal-fired MHD generators. 16th quarterly technical progress report, December 16, 1980-March 31, 1981  

DOE Green Energy (OSTI)

The successful design of full-scale, open-cycle, coal-fired MHD generators for baseload electrical production requires a detailed understanding of the plasma chemical and plasma dynamic characteristics of anticipated combustor and channel fluids. Progress in efforts to model the efficiency of an open-cycle, coal-fired MHD channel based on the characterization of the channel flow as well as laboratory experiments to validate the modeling effort is reported. In addition, studies related to understanding arcing and corrosion phenomena in the vicinity of an anode are reported.

Wormhoudt, J.; Yousefian, V.; Weinberg, M.; Kolb, C.; Martinez-Sanchez, M.; Cheng, W.; Dvore, D.; Freedman, A.; Stanton, A.; Stewart, G.

1981-05-01T23:59:59.000Z

277

Engineering development of advanced coal-fired low-emission boiler systems. Technical progress report No. 4, July--September 1993  

Science Conference Proceedings (OSTI)

The overall objective of the Project is the expedited commercialization of advanced coal-fired low-emission boiler systems. The specified primary objectives are: NOx emissions not greater than one-third NSPS; SOx emissions not greater than one-third NSPS; and particulate emissions not greater than one-half NSPS. The specific secondary objectives are: improved ash disposability and reduced waste generation; reduced air toxics emissions; and increased generating efficiency. The final deliverables are a design data base that will allow future coal-fired power plants to meet the stated objectives and a preliminary design of a commercial generation unit.

Not Available

1993-12-29T23:59:59.000Z

278

Engineering development of coal-fired high-performance power systems. Progress report, April 1--June 30, 1996  

SciTech Connect

In Phase 1 of the project, a conceptual design of a coal-fired, high-performance power system (HIPPS) was developed, and small-scale R and D was done in critical areas of the design. The current phase of the project includes development through the pilot plant stage and design of a prototype plant that would be built in Phase 3. The power-generating system being developed in this project will be an improvement over current coal-fired systems. It is a combined-cycle plant. This arrangement is referred to as the All Coal HIPPS because it does not require any other fuels for normal operation. A fluidized bed, air-blown pyrolyzer converts coal into fuel gas and char. The char is fired in a high-temperature advanced furnace (HITAF) which heats both air for a gas turbine and steam for a steam turbine. The fuel gas from the pyrolyzer goes to a topping combustor where it is used to raise the air entering the gas turbine to 1288 C. In addition to the HITAF, steam duty is achieved with a heat-recovery steam generator (HRSG) in the gas turbine exhaust stream and economizers in the HITAF flue gas exhaust stream. Progress during the quarter is described.

1996-12-31T23:59:59.000Z

279

Conceptual design of a coal-fired MHD retrofit plant. Topical report, Seed Regeneration System Study 2  

SciTech Connect

Westinghouse Advanced Energy Systems (WAES), through Contract No. DE-AC22-87PC79668 funded by US DOE/PETC, is conducting a conceptual design study to evaluate a coal-fired magnetohydrodynamic (MHD) retrofit of a utility plant of sufficient size to demonstrate the technical and future economic viability of an MHD system operating within an electric utility environment. The objective of this topical report is to document continuing seed regeneration system application studies and the definition of will system integration requirements for the Scholz MHD retrofit plant design. MHD power plants require the addition of a seeding material in the form of potassium to enhance the ionization of the high temperature combustion gas in the MHD channel. This process has an added environmental advantage compared to other types of coal-fired power plants in that the potassium combines with the naturally occurring sulfur in the coal to form a potassium sulfate flyash (K{sub 2}SO{sub 4}) which can be removed from the process by appropriate particulate control equipment. Up to 100% of the Sulfur in the coal can be removed by this process thereby providing environmentally clean power plant operation that is better than required by present and anticipated future New Source Performance Standards (NSPS).

1992-11-01T23:59:59.000Z

280

Assessment of pulverized-coal-fired combustion performance: Final report for the period September 1980--September 1983  

Science Conference Proceedings (OSTI)

The purpose of this program was to evaluate an engineering analysis procedure which could be used to assess the impact on thermal performance of converting gas and oil fired equipment to coal. The program consisted of four major tasks: (1) Engineering Analysis. The objective was to evaluate currently available models which could be used to predict combustor performance and to define a procedure which could be used to assess the impact of a coal firing in a boiler or furnace; (2) Reactor Studies. The purpose was to evaluate, under controlled conditions, the radiative properties of fly ash clouds; (3) Pilot Scale Experiments. This involved a combustion trial with gas and coals which were burned at 0.7 /times/ 10/sup 6/ Btu/hr in a pilot-scale combustor. The purpose was to verify and supplement the results of the small-scale reactor studies on the radiant properties of coal flames at larger scale; (4) Reporting. Engineering analysis procedures were used to identify those fuels related properties which had a major impact on the thermal performance of furnaces. The major result of the study is that thermal performance of coal-fired furnaces is dominated by the formation of fly ash deposits on the heat transfer surfaces. The key parameters which influence thermal performance are: thickness, thermal conductivity, and surface emissivity or absorptivity. 105 refs., 170 figs., 29 tabs.

Richter, W.F.; Clark, W.; Pohl, J.H.; Payne, R.

1987-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Near-term implications of a ban on new coal-fired power plants in the United States  

Science Conference Proceedings (OSTI)

Large numbers of proposed new coal power generators in the United States have been cancelled, and some states have prohibited new coal power generators. We examine the effects on the U.S. electric power system of banning the construction of coal-fired electricity generators, which has been proposed as a means to reduce U.S. CO{sub 2} emissions. The model simulates load growth, resource planning, and economic dispatch of the Midwest Independent Transmission System Operator (ISO), Inc., Electric Reliability Council of Texas (ERCOT), and PJM under a ban on new coal generation and uses an economic dispatch model to calculate the resulting changes in dispatch order, CO{sub 2} emissions, and fuel use under three near-term (until 2030) future electric power sector scenarios. A national ban on new coal-fired power plants does not lead to CO{sub 2} reductions of the scale required under proposed federal legislation such as Lieberman-Warner but would greatly increase the fraction of time when natural gas sets the price of electricity, even with aggressive wind and demand response policies. 50 refs., 5 figs., 4 tabs.

Adam Newcomer; Jay Apt [Carnegie Mellon University, Pittsburgh, PA (United States). Carnegie Mellon Electricity Industry Center

2009-06-15T23:59:59.000Z

282

Fault diagnosis for the feedwater heater system of a 300MW coal-fired power generating unit based on RBF neural network  

Science Conference Proceedings (OSTI)

In this paper, a new style radial basis function (RBF) neural network is used for fault diagnosis of the high-pressure feed-water heater system of a coal-fired power generating unit. The structure of the RBF network and its training algorithm are given. ...

Liangyu Ma; Yongguang Ma; Jin Ma

2005-08-01T23:59:59.000Z

283

Greener Solvent Selection and Solvent Recycling for CO2 Capture Economically removing CO2 from the flue gases of coal-fired power plants would alleviate concerns  

E-Print Network (OSTI)

the flue gases of coal-fired power plants would alleviate concerns about their contribution to global of candidate solvents and solvent blends is very large, a purely experimental search is impossible. In recent and solvent blends and a new and efficient multiobjective optimization (MOP) framework under uncertainty[4

Ben-Arie, Jezekiel

284

Proceedings of the joint contractors meeting: FE/EE Advanced Turbine Systems conference FE fuel cells and coal-fired heat engines conference  

SciTech Connect

The joint contractors meeting: FE/EE Advanced Turbine Systems conference FEE fuel cells and coal-fired heat engines conference; was sponsored by the US Department of Energy Office of Fossil Energy and held at the Morgantown Energy Technology Center, P.O. Box 880, Morgantown, West Virginia 26507-0880, August 3--5, 1993. Individual papers have been entered separately.

Geiling, D.W. [ed.

1993-08-01T23:59:59.000Z

285

A COMPARISON OF THE NUCLEAR DEFENSE CAPABILITIES ON NUCLEAR AND COAL-FIRED POWER PLANTS. FUEL COST STUDY VARIOUS REACTORS AT 100 AND 300 Mwe  

SciTech Connect

Appendices C and D may further be identified as SL1925 and CF-61-12- 20(Rev.), respectively. A comparative report is presented in which the economics and feasibility of plant protection from nuclear attack by plant hardening, remote siting, and utilization of optional fueling concepts for the coal-fired plant are evaluated. (J.R.D.)

Gift, E.H.

1962-05-29T23:59:59.000Z

286

POTENTIAL HEALTH RISK REDUCTION ARISING FROM REDUCED MERCURY EMISSIONS FROM COAL FIRED POWER PLANTS.  

Science Conference Proceedings (OSTI)

The U.S. Environmental Protection Agency (EPA) has announced plans to regulate mercury (Hg) emissions from coal-fired power plants. EPA has not prepared a quantitative assessment of the reduction in risk that could be achieved through reduction in coal plant emissions of Hg. To address this issue, Brookhaven National Laboratory (BNL) with support from the U.S. Department of Energy Office of Fossil Energy (DOE FE) prepared a quantitative assessment of the reduction in human health risk that could be achieved through reduction in coal plant emissions of Hg. The primary pathway for Hg exposure is through consumption of fish. The most susceptible population to Hg exposure is the fetus. Therefore the risk assessment focused on consumption of fish by women of child-bearing age. Dose response factors were generated from studies on loss of cognitive abilities (language skills, motor skills, etc.) by young children whose mothers consumed large amounts of fish with high Hg levels. Population risks were estimated for the general population in three regions of the country, (the Midwest, Northeast, and Southeast) that were identified by EPA as being heavily impacted by coal emissions. Three scenarios for reducing Hg emissions from coal plants were considered: (1) A base case using current conditions; (2) A 50% reduction; and, (3) A 90% reduction. These reductions in emissions were assumed to translate linearly into a reduction in fish Hg levels of 8.6% and 15.5%, respectively. Population risk estimates were also calculated for two subsistence fisher populations. These groups of people consume substantially more fish than the general public and, depending on location, the fish may contain higher Hg levels than average. Risk estimates for these groups were calculated for the three Hg levels used for the general population analyses. Analysis shows that the general population risks for exposure of the fetus to Hg are small. Estimated risks under current conditions (i.e., no specific Hg controls) ranged from 5.7 x 10{sup -6} in the Midwest to 2 x 10{sup -5} in the Southeast. Reducing emissions from coal plants by 90% reduced the estimated range in risk to 5 x 10{sup -6} in the Midwest and 1.5 x 10{sup -5} in Southeast, respectively. The population risk for the subsistence fisher using the Southeast regional fish Hg levels was 3.8 x 10{sup -3}, a factor of 200 greater than the general population risk. For the subsistence fishers and the Savannah River Hg levels, the population risk was 4.3 x 10{sup -5}, a factor of 2 greater than for the general population. The estimated risk reductions from a 90% reduction in coal plant Hg emissions ranged from 25%-68%, which is greater than the assumed reduction in Hg levels in fish, (15.5%). To place this risk in perspective, there are approximately 4 x 10{sup 6} births/year in the U.S (National Vital Statistics Report, 2000). Assuming that the Southeast risk level (the highest of the regions) is appropriate for the entire U.S., an estimate of 80 newborn children per year have a 5% chance of realizing any of the 16 adverse effects used to generate the DRF. If Hg emissions from power plants are reduced 90%, the number of children at risk is reduced to 60.

SULLIVAN,T.M.LIPFERT,F.W.MORRIS,S.C.MOSKOWITZ,P.D.

2001-09-01T23:59:59.000Z

287

Sustainability Assessment of Coal-Fired Power Plants with Carbon Capture and Storage  

Science Conference Proceedings (OSTI)

Carbon capture and sequestration (CCS) has the ability to dramatically reduce carbon dioxide (CO2) emissions from power production. Most studies find the potential for 70 to 80 percent reductions in CO2 emissions on a life-cycle basis, depending on the technology. Because of this potential, utilities and policymakers are considering the wide-spread implementation of CCS technology on new and existing coal plants to dramatically curb greenhouse gas (GHG) emissions from the power generation sector. However, the implementation of CCS systems will have many other social, economic, and environmental impacts beyond curbing GHG emissions that must be considered to achieve sustainable energy generation. For example, emissions of nitrogen oxides (NOx), sulfur oxides (SOx), and particulate matter (PM) are also important environmental concerns for coal-fired power plants. For example, several studies have shown that eutrophication is expected to double and acidification would increase due to increases in NOx emissions for a coal plant with CCS provided by monoethanolamine (MEA) scrubbing. Potential for human health risks is also expected to increase due to increased heavy metals in water from increased coal mining and MEA hazardous waste, although there is currently not enough information to relate this potential to actual realized health impacts. In addition to environmental and human health impacts, supply chain impacts and other social, economic, or strategic impacts will be important to consider. A thorough review of the literature for life-cycle analyses of power generation processes using CCS technology via the MEA absorption process, and other energy generation technologies as applicable, yielded large variability in methods and core metrics. Nonetheless, a few key areas of impact for CCS were developed from the studies that we reviewed. These are: the impact of MEA generation on increased eutrophication and acidification from ammonia emissions and increased toxicity from MEA production and the impact of increased coal use including the increased generation of NOx from combustion and transportation, impacts of increased mining of coal and limestone, and the disposal of toxic fly ash and boiler ash waste streams. Overall, the implementing CCS technology could contribute to a dramatic decrease in global GHG emissions, while most other environmental and human health impact categories increase only slightly on a global scale. However, the impacts on human toxicity and ecotoxicity have not been studied as extensively and could have more severe impacts on a regional or local scale. More research is needed to draw strong conclusions with respect to the specific relative impact of different CCS technologies. Specifically, a more robust data set that disaggregates data in terms of component processes and treats a more comprehensive set of environmental impacts categories from a life-cycle perspective is needed. In addition, the current LCA framework lacks the required temporal and spatial scales to determine the risk of environmental impact from carbon sequestration. Appropriate factors to use when assessing the risk of water acidification (groundwater/oceans/aquifers depending on sequestration site), risk of increased human toxicity impact from large accidental releases from pipeline or wells, and the legal and public policy risk associated with licensing CO2 sequestration sites are also not currently addressed. In addition to identifying potential environmental, social, or risk-related issues that could impede the large-scale deployment of CCS, performing LCA-based studies on energy generation technologies can suggest places to focus our efforts to achieve technically feasible, economically viable, and environmentally conscious energy generation technologies for maximum impact.

Widder, Sarah H.; Butner, R. Scott; Elliott, Michael L.; Freeman, Charles J.

2011-11-30T23:59:59.000Z

288

Multiscale Modeling of Grain Boundary Segregation and Embrittlement in Tungsten for Mechanistic Design of Alloys for Coal Fired Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

Fairbanks, AK * Morgantown, WV * Pittsburgh, PA * Sugar Land, TX Fairbanks, AK * Morgantown, WV * Pittsburgh, PA * Sugar Land, TX Website: www.netl.doe.gov Customer Service: 1-800-553-7681 Multiscale Modeling of Grain Boundary Segregation and Embrittlement in Tungsten for Mechanistic Design of Alloys for Coal Fired Plants Background The Department of Energy (DOE) National Energy Technology Laboratory (NETL) University Coal Research (UCR) Program seeks to further develop the understanding of coal utilization. Since the program's inception in 1979, its primary objectives have been to improve our understanding of the chemical and physical processes involved in the conversion and utilization of coal in an environmentally acceptable manner; maintain and upgrade the coal research capabilities and facilities of U.S. colleges and

289

Technical progress report for the Magnetohydrodynamics Coal-Fired Flow Facility: October 1, 1992--December 31, 1992  

DOE Green Energy (OSTI)

Progress is reported on a multitask contract to develop technology for steam bottoming cycle of a Combined Cycle MHD Steam Power Plant. The report describes a 314 hour proof-of-concept (POC) test completed during the quarter. Results include secondary combustion and effect of potassium on the light-off temperature, fouling of heat transfer surfaces, particulate clean-up device performance and advanced diagnostic system performance. Test results on ceramic materials and tubes directed toward the development of a high temperature recuperative air heater are summarized. Results of data analysis of previous tests that are reported include the continuing analysis of tube materials that were exposed to 1500 and 2000 hours of eastern coal fired operation during the previously completed 2000 hour POC test series on eastern, high sulfur coal.

Not Available

1993-06-01T23:59:59.000Z

290

ADVANCED FLUE GAS CONDITIONING AS A RETROFIT UPGRADE TO ENHANCE PM COLLECTION FROM COAL-FIRED ELECTRIC UTILITY BOILERS  

Science Conference Proceedings (OSTI)

The U.S. Department of Energy and ADA Environmental Solutions have begun a project to develop commercial flue gas conditioning additives. The objective is to develop conditioning agents that can help improve particulate control performance of smaller or under-sized electrostatic precipitators on utility coal-fired boilers. The new chemicals will be used to control both the electrical resistivity and the adhesion or cohesivity of the flyash. There is a need to provide cost-effective and safer alternatives to traditional flue gas conditioning with SO{sub 3} and ammonia. During the second reporting quarter for this project, design and development is continuing on an electrostatic tensiometer to measure cohesion of flyash layers. A dedicated test fixture to automate flyash electrical resistivity testing is also underway. Ancillary instrumentation to control gas humidification within these test fixtures is also under construction.

Kenneth E. Baldrey

2000-09-01T23:59:59.000Z

291

A Sensor System Based on Semi-Conductor Metal Oxide Technology for In Situ Detection of Coal Fired Combustion Gases  

SciTech Connect

Sensor Research and Development Corporation (SRD) proposed a two-phase program to develop a robust, autonomous prototype analyzer for in situ, real-time detection, identification, and measurement of coal-fired combustion gases and perform field-testing at an approved power generation facility. SRD developed and selected sensor materials showing selective responses to carbon monoxide, carbon dioxide, nitric oxide, nitrogen dioxide, ammonia, sulfur dioxide and hydrogen chloride. Sensor support electronics were also developed to enable prototype to function in elevated temperatures without any issues. Field-testing at DOE approved facility showed the ability of the prototype to detect and estimate the concentration of combustion by-products accurately with relatively low false-alarm rates at very fast sampling intervals.

Brent Marquis

2007-05-31T23:59:59.000Z

292

Engineering Feasibility of CO2 Capture on an Existing U.S. Coal-Fired Power Plant  

NLE Websites -- All DOE Office Websites (Extended Search)

FEASIBILITY OF CO FEASIBILITY OF CO 2 CAPTURE ON AN EXISTING US COAL-FIRED POWER PLANT Nsakala ya Nsakala (nsakala.y.nsakala@power.alstom.com; 860-285-2018) John Marion (john.l.marion@power.alstom.com; 860-285-4539) Carl Bozzuto (carl.bozzuto@power.alstom.com; 860-285-5007) Gregory Liljedahl (greg.n.liljedahl@power.alstom.com; 860-285-4833) Mark Palkes (mark.palkes@power.alstom.com; 860-285-2676) ALSTOM Power Inc. US Power Plant Laboratories 2000 Day Hill Rd. Windsor, CT 06095 David Vogel (david.c.vogel@us.abb.com; 713-821-4312) J.C. Gupta (jcgupta@us.abb.com; 713-821-5093) ABB Lummus Global Inc. 3010 Briarpark Houston, TX 77042 Manoj Guha (mkguha@aep.com; 614-223-1285) American Electric Power 1 Riverside Plaza Columbus, OH 43215 Howard Johnson (hjohnson@odod.state.oh.us; 614-644-8368)

293

Feasibility study of burning waste paper in coal-fired boilers on Air Force installations. Master's thesis  

Science Conference Proceedings (OSTI)

This thesis examined the feasibility of using waste paper derived fuel in coal-fired boilers on Air Force installations in an attempt to help solve air pollution and solid waste disposal problems. The implementation of waste paper derived fuel was examined from both a technical acceptability and an economic feasibility viewpoint. The majority of data for this study was obtained through literature reviews and personal interviews. Waste paper was found to be technically acceptable for use as fuel. However, waste paper has certain characteristics that may create problems during combustion and therefore further research is required. These problems included the possibility of increased nitrous oxide emissions, increased volatile emissions, dioxin and furan emissions, formation of hydrochloric acid, and the presence of heavy metals in emissions and ash.

Smith, K.P.

1993-09-01T23:59:59.000Z

294

Oxy-fuel Combustion and Integrated Pollutant Removal as Retrofit Technologies for Removing CO2 from Coal Fired Power Plants  

Science Conference Proceedings (OSTI)

One third of the US installed capacity is coal-fired, producing 49.7% of net electric generation in 20051. Any approach to curbing CO2 production must consider the installed capacity and provide a mechanism for preserving this resource while meeting CO2 reduction goals. One promising approach to both new generation and retrofit is oxy-fuel combustion. Using oxygen instead of air as the oxidizer in a boiler provides a concentrated CO2 combustion product for processing into a sequestration-ready fluid.... Post-combustion carbon capture and oxy-fuel combustion paired with a compression capture technology such as IPR are both candidates for retrofitting pc combustion plants to meet carbon emission limits. This paper will focus on oxy-fuel combustion as applied to existing coal power plants.

Ochs, T.L.; Oryshchyn, D.B.; Summers, C.A.; Gerdemann, S.J.

2001-01-01T23:59:59.000Z

295

ADVANCED FLUE GAS CONDITIONING AS A RETROFIT UPGRADE TO ENHANCE PM COLLECTION FROM COAL-FIRED ELECTRIC UTILITY BOILERS  

SciTech Connect

The U.S. Department of Energy and ADA Environmental Solutions are engaged in a project to develop commercial flue gas conditioning additives. The objective is to develop conditioning agents that can help improve particulate control performance of smaller or under-sized electrostatic precipitators on utility coal-fired boilers. The new chemicals will be used to control both the electrical resistivity and the adhesion or cohesivity of the fly ash. There is a need to provide cost-effective and safer alternatives to traditional flue gas conditioning with SO{sub 3} and ammonia. During this reporting quarter, progress was made in obtaining an industry partner for a long-term demonstration and in technology transfer activities. Engineering and equipment procurement activities related to the long-term demonstration were also completed.

Kenneth E. Baldrey

2001-10-01T23:59:59.000Z

296

[Engineering development of advanced coal-fired low-emission boiler systems]. Technical progress report, October--December 1995  

Science Conference Proceedings (OSTI)

The overall objective of the Project is the expedited commercialization of advanced coal-fired low-emisssion boiler systems. The primary objectives are: NO{sub x} emissions, lb/million Btu; SO{sub 2} emissions, lb/million Btu; particulate emissions, lb/million Btu; and net plant efficiency, not less than 42%. The secondary objectives are: improved ash disposability; reduced waste generation; and reduced air toxics emissions. Accomplishments to date are summarized for the following tasks: task 1, project planning and management; task 7, component development and optimization; task 8, preliminary POC test facility design; task 9, subsystem test design and plan; task 10, subsystem test unit construction; and task 11, subsystem test operation and evaluation.

Wesnor, J.D.; Bakke, E. [ABB Environmental Systems, Birmingham, AL (United States); Bender, D.J.; Kaminski, R.S. [Raytheon Engineers and Constructors, Inc., Philadelphia, PA (United States)

1995-12-31T23:59:59.000Z

297

Evaluation of the behavior of shrouded plasma spray coatings in the platen superheater of coal-fired boilers  

SciTech Connect

Nickel- and cobalt-based coatings were formulated by a shrouded plasma spray process on boiler tube steels, namely, ASTM-SA210-grade A1 (GrA1), ASTM-SA213-T-11 (T11), and ASTM-SA213-T-22 (T22). The Ni-22Cr-10A1-1Y alloy powder was sprayed as a bond in each case before the final coating. The degradation behavior of the bared and coated steels was studied in the platen superheater of the coal-fired boiler. The samples were inserted through the soot blower dummy points with the help of stainless steel wires. The coatings were found to be effective in increasing resistance to degradation in the given boiler environment. The maximum protection was observed in the case of Stellite-6 (St-6) coating.

Sidhu, B.S.; Prakash, S. [GZS College of Engineering & Technology, Bathinda (India). Dept. of Mechanical Engineering

2006-06-15T23:59:59.000Z

298

Characterization of open-cycle, coal-fired MHD generators. Eleventh quarterly technical progress report, May 1-July 31, 1979  

DOE Green Energy (OSTI)

The successful design of full-scale open-cycle, coal-fired MHD generators for baseload electrical production requires a detailed understanding of the plasma chemical and plasma dynamic characteristics of anticipated combustor and channel fluids. The report documents the development of a diffusion controlled heterogeneous condensation model and channel heat loss model for incorporation into the PACKAGE code used to calculate core flow plasma properties and generator efficiency. PACKAGE calculations comparing realistic baseload subsonic and supersonic generator models are also presented. Progress on the refinement of a laboratory scale coal combustion plasma source and its associated molecular beam mass spectrometer diagnostic and diode laser absorption plasma temperature measurement systems is documented. Finally, progress on the development of a numerical model describing arc behavior in MHD electrode boundary layers is presented.

Kolb, C.E.; Wormhoudt, J.; Yousefian, V.; Cheng, W.; Bien, F.; Dvore, D.; Martinez-Sanchez, M.

1979-08-01T23:59:59.000Z

299

Elisabeth Mansfield  

Science Conference Proceedings (OSTI)

... She is also interested in cooking, making at least one new recipe per week. Google Scholar Citation Page. Research Interests: ...

2013-04-24T23:59:59.000Z

300

Mercury Measurements Characterizing the Impact of SCR on Mercury: Consol Test Site 10---Eastern-Bituminous Coal-Fired Power Plant w ith an SCR, ESP and Wet FGD  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP) - wet flue gas desulfurization (FGD) combination or a spray dyer absorber fabric filter (SDA-FF) combination. In this program CONSOL is to determine mercury speciation and removal at 10 coal-fired faci...

2005-11-28T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

The Mansfield Two-Stage, Low BTU Gasification System: Report of Operations  

E-Print Network (OSTI)

The least expensive way to produce gas from coal is by low Btu gasification, a process by which coal is converted to carbon monoxide and hydrogen by reacting it with air and steam. Low Btu gas, which is used near its point of production, eliminates the high costs of oxygen and methanation required to produce gas that can be transmitted over long distance. Standard low Btu fixed bed gasifiers have historically been plagued by three constraints; namely, the production of messy tars and oils, the inability to utilize caking coals, and the inability to accept coal fines. Mansfield Carbon Products, Inc., a subsidiary of A.T. Massey Coal Company, has developed an atmospheric pressure, two-stage process that eliminates these three problems.

Blackwell, L. T.; Crowder, J. T.

1983-01-01T23:59:59.000Z

302

TOXECON RETROFIT FOR MERCURY AND MULTI-POLLUTANT CONTROL-ON THREE 90 MW COAL FIRED BOILERS  

Science Conference Proceedings (OSTI)

With the Nation's coal-burning utilities facing tighter controls on mercury pollutants, the U.S. Department of Energy is supporting projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by a particle control device along with the other solid material, primarily fly ash. We Energies has over 3,200 MW of coal-fired generating capacity and supports an integrated multi-emission control strategy for SO{sub 2}, NO{sub x} and mercury emissions while maintaining a varied fuel mix for electric supply. The primary goal of this project is to reduce mercury emissions from three 90 MW units that burn Powder River Basin coal at the We Energies Presque Isle Power Plant. Additional goals are to reduce nitrogen oxide (NO{sub x}), sulfur dioxide (SO{sub 2}), and particulate matter (PM) emissions, allow for reuse and sale of fly ash, demonstrate a reliable mercury continuous emission monitor (CEM) suitable for use in the power plant environment, and demonstrate a process to recover mercury captured in the sorbent. To achieve these goals, We Energies (the Participant) will design, install, and operate a TOXECON{trademark} (TOXECON) system designed to clean the combined flue gases of units 7, 8, and 9 at the Presque Isle Power Plant. TOXECON is a patented process in which a fabric filter system (baghouse) installed down stream of an existing particle control device is used in conjunction with sorbent injection for removal of pollutants from combustion flue gas. For this project, the flue gas emissions will be controlled from the three units using a single baghouse. Mercury will be controlled by injection of activated carbon or other novel sorbents, while NO{sub x} and SO{sub 2} will be controlled by injection of sodium based or other novel sorbents. Addition of the TOXECON baghouse will provide enhanced particulate control. Sorbents will be injected downstream of the existing particle collection device to allow for continued sale and reuse of captured fly ash from the existing particulate control device, uncontaminated by activated carbon or sodium sorbents. Methods for sorbent regeneration, i.e. mercury recovery from the sorbent, will be explored and evaluated. For mercury concentration monitoring in the flue gas streams, components available for use will be evaluated and the best available will be integrated into a mercury CEM suitable for use in the power plant environment. This project will provide for the use of a novel multi-pollutant control system to reduce emissions of mercury while minimizing waste, from a coal-fired power generation system.

Richard E. Johnson

2004-10-26T23:59:59.000Z

303

TOXECON RETROFIT FOR MERCURY AND MULTI-POLLUTANT CONTROL ON THREE 90-MW COAL-FIRED BOILERS  

SciTech Connect

With the Nation's coal-burning utilities facing tighter controls on mercury pollutants, the U.S. Department of Energy is supporting projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by a particulate control device along with the other solid material, primarily fly ash. We Energies has over 3,200 MW of coal-fired generating capacity and supports an integrated multi-emission control strategy for SO{sub 2}, NO{sub x}, and mercury emissions while maintaining a varied fuel mix for electric supply. The primary goal of this project is to reduce mercury emissions from three 90-MW units that burn Powder River Basin coal at the We Energies Presque Isle Power Plant. Additional goals are to reduce nitrogen oxide (NO{sub x}), sulfur dioxide (SO{sub 2}), and particulate matter (PM) emissions, allow for reuse and sale of fly ash, demonstrate a reliable mercury continuous emission monitor (CEM) suitable for use in the power plant environment, and demonstrate a process to recover mercury captured in the sorbent. To achieve these goals, We Energies (the Participant) will design, install, and operate a TOXECON{trademark} system designed to clean the combined flue gases of Units 7, 8, and 9 at the Presque Isle Power Plant. TOXECON{trademark} is a patented process in which a fabric filter system (baghouse) installed downstream of an existing particle control device is used in conjunction with sorbent injection for removal of pollutants from combustion flue gas. For this project, the flue gas emissions will be controlled from the three units using a single baghouse. Mercury will be controlled by injection of activated carbon or other novel sorbents, while NO{sub x} and SO{sub 2} will be controlled by injection of sodium-based or other novel sorbents. Addition of the TOXECON{trademark} baghouse will provide enhanced particulate control. Sorbents will be injected downstream of the existing particle collection device to allow for continued sale and reuse of captured fly ash from the existing particulate control device, uncontaminated by activated carbon or sodium sorbents. Methods for sorbent regeneration, i.e., mercury recovery from the sorbent, will be explored and evaluated. For mercury concentration monitoring in the flue gas streams, components available for use will be evaluated and the best available will be integrated into a mercury CEM suitable for use in the power plant environment. This project will provide for the use of a control system to reduce emissions of mercury while minimizing waste from a coal-fired power generation system.

Richard E. Johnson

2006-01-25T23:59:59.000Z

304

TOXECON RETROFIT FOR MERCURY AND MULTI-POLLUTANT CONTROL ON THREE 90-MW COAL-FIRED BOILERS  

SciTech Connect

With the Nation's coal-burning utilities facing tighter controls on mercury pollutants, the U.S. Department of Energy is supporting projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by a particulate control device along with the other solid material, primarily fly ash. We Energies has over 3,200 MW of coal-fired generating capacity and supports an integrated multi-emission control strategy for SO{sub 2}, NO{sub x}, and mercury emissions while maintaining a varied fuel mix for electric supply. The primary goal of this project is to reduce mercury emissions from three 90-MW units that burn Powder River Basin coal at the We Energies Presque Isle Power Plant. Additional goals are to reduce nitrogen oxide (NO{sub x}), sulfur dioxide (SO{sub 2}), and particulate matter (PM) emissions, allow for reuse and sale of fly ash, demonstrate a reliable mercury continuous emission monitor (CEM) suitable for use in the power plant environment, and demonstrate a process to recover mercury captured in the sorbent. To achieve these goals, We Energies (the Participant) will design, install, and operate a TOXECON{trademark} system designed to clean the combined flue gases of Units 7, 8, and 9 at the Presque Isle Power Plant. TOXECON{trademark} is a patented process in which a fabric filter system (baghouse) installed downstream of an existing particle control device is used in conjunction with sorbent injection for removal of pollutants from combustion flue gas. For this project, the flue gas emissions will be controlled from the three units using a single baghouse. Mercury will be controlled by injection of activated carbon or other novel sorbents, while NO{sub x} and SO{sub 2} will be controlled by injection of sodium-based or other novel sorbents. Addition of the TOXECON{trademark} baghouse will provide enhanced particulate control. Sorbents will be injected downstream of the existing particle collection device to allow for continued sale and reuse of captured fly ash from the existing particulate control device, uncontaminated by activated carbon or sodium sorbents. Methods for sorbent regeneration, i.e., mercury recovery from the sorbent, will be explored and evaluated. For mercury concentration monitoring in the flue gas streams, components available for use will be evaluated and the best available will be integrated into a mercury CEM suitable for use in the power plant environment. This project will provide for the use of a control system to reduce emissions of mercury while minimizing waste from a coal-fired power generation system.

Steven T. Derenne

2006-04-28T23:59:59.000Z

305

CO2 Capture from Coal-Fired Utility Generation Plant Exhausts and Sequestration by a Biomimetic Route Based on Enzymatic Catalysts-Current Status  

NLE Websites -- All DOE Office Websites (Extended Search)

from Coal-Fired Utility Generation Plant Exhausts, and from Coal-Fired Utility Generation Plant Exhausts, and Sequestration by a Biomimetic Route Based on Enzymatic Catalysis - Current Status Gillian M. Bond (gbond@nmt.edu; 505-835-5653) Margaret-Gail Medina (magail@nmt.edu; 505-835-5229) New Mexico Tech 801 Leroy Socorro, NM 87801 John Stringer (jstringe@epri.com; 650-855-2472) Electric Power Research Institute 3412 Hillview Avenue Palo Alto, CA 94304 F. Arzum Simsek-Ege (fatma.a.simsek-egel@intel.com; 505-893-8694) Intel Corporation Albuquerque, New Mexico Introduction A range of carbon management strategies will have to be implemented if meaningful reductions in CO 2 emissions are to be achieved in response to concerns about global climate change. It is becoming increasingly clear that some form or forms of carbon

306

A review of potential turbine technology options for improving the off-design performance of direct coal-fired gas turbines in base load service. Second topical report  

SciTech Connect

The January, 1988 draft topical report, entitled ``An Assessment of Off-Design Particle Control Performance on Direct Coal-Fired Gas Turbine Systems`` [Ref.1.1], identified the need to assess potential trade-offs in turbine aerodynamic and thermodynamic design which may offer improvements in the performance, operational and maintenance characteristics of open-cycle, direct coal-fired, combustion gas turbines. In this second of a series of three topical reports, an assessment of the technical options posed by the above trade-offs is presented. The assessment is based on the current status of gas turbine technology. Several industry and university experts were contacted to contribute to the study. Literature sources and theoretical considerations are used only to provide additional background and insight to the technology involved.

Thomas, R.L.

1988-03-01T23:59:59.000Z

307

A review of potential turbine technology options for improving the off-design performance of direct coal-fired gas turbines in base load service  

SciTech Connect

The January, 1988 draft topical report, entitled An Assessment of Off-Design Particle Control Performance on Direct Coal-Fired Gas Turbine Systems'' (Ref.1.1), identified the need to assess potential trade-offs in turbine aerodynamic and thermodynamic design which may offer improvements in the performance, operational and maintenance characteristics of open-cycle, direct coal-fired, combustion gas turbines. In this second of a series of three topical reports, an assessment of the technical options posed by the above trade-offs is presented. The assessment is based on the current status of gas turbine technology. Several industry and university experts were contacted to contribute to the study. Literature sources and theoretical considerations are used only to provide additional background and insight to the technology involved.

Thomas, R.L.

1988-03-01T23:59:59.000Z

308

Engineering development of advanced coal-fired low-emission boiler systems. Quarterly technical progress report No. 17, October 1, 1996--December 31, 1996  

SciTech Connect

This report describes the work performed between October 1 and December 31, 1996 by the ABB team on U.S. Department of Energy project ``Engineering Development of Advanced Coal-Fired Low-Emission Boiler Systems`` (LEBS), which is part of the DOE`s Combustion 2000 Program. The overall objective of the LEBS Project is to dramatically improve environmental performance of future coal-fired power plants without adversely impacting efficiency or the cost of electricity. Near-term technologies, i.e., advanced technologies that are partially developed, will be used to reduce NO{sub x} and SO{sub 2} emission to one-sixth current NSPS limits and particulates to one- third current NSPS limits.

Regan, J.W.; Bender, D.J.; Clark, J.P.; Wesnor, J.D.

1997-01-01T23:59:59.000Z

309

Integrated Knowledge Framework (IKF) for Coal-Fired Power Plants: An Analysis of the Data, Information, and Knowledge Requirements for the Economic Operation and Maintenance of Coal-Fired Power Plants Volumes 1-3; Volume 1, Summary; Volume 2, IKF Mode...  

Science Conference Proceedings (OSTI)

This project produced an integrated knowledge framework (IKF) that describes the management and operational functions at a generic, coal-fired power plant. This IKF identifies and controls the flow of data, information, and knowledge required for important fossil power plant functions. In addition, the IKF provides a benchmark for comparing existing plant practices and implementing improvements to those practices.

1996-05-29T23:59:59.000Z

310

Development and Demonstration of Waste Heat Integration with Solvent Process for More Efficient CO2 Removal from Coal-Fired Flue Gas  

NLE Websites -- All DOE Office Websites (Extended Search)

and Demonstration of and Demonstration of Waste Heat Integration with Solvent Process for More Efficient CO 2 Removal from Coal-Fired Flue Gas Background The mission of the U.S. Department of Energy/National Energy Technology Laboratory (DOE/NETL) Existing Plants, Emissions, & Capture (EPEC) Research & Development (R&D) Program is to develop innovative environmental control technologies to enable full use of the nation's vast coal reserves, while at the same time allowing the current fleet of coal-

311

Multi-Pathway Human Health and Ecological Risk Assessment for a Model Coal-Fired Power Plant Using a Revised Arsenic Bioconcentratio n Factor for Edible Fish  

Science Conference Proceedings (OSTI)

This report describes a multimedia human health and ecosystem risk study of a model coal-fired power plant in a model setting, using data from an actual power plant that have been transposed to a lakeside setting in the same state. Values of arsenic concentrations in similar ecosystem settings were applied to calculate its contributions to risk.BackgroundThere is increased scientific and regulatory interest in the suite of risks to human health and ecosystems ...

2013-08-29T23:59:59.000Z

312

Selenium Removal by Iron Cementation from a Coal-Fired Power Plant Flue Gas Desulfurization Wastewater in a Continuous Flow System-- a Pilot Study  

Science Conference Proceedings (OSTI)

This technical update describes work funded by the Electric Power Research Institute (EPRI) and performed by MSE Technology Applications, Inc. (MSE) at a coal-fired power plant burning Powder River Basin (PRB) coal (identified in this report as Plant E). This work was based on encouraging results obtained during previous EPRI-funded work on flue gas desulfurization (FGD) wastewater treatability testing by MSE, which focused on selenium removal from a variety of FGD wastewater sources. The results from th...

2009-07-29T23:59:59.000Z

313

Mercury Measurements Characterizing the Impact of SCR on Mercury: Consol Test Site 5 - Eastern Bituminous Coal-Fired Power Plant wi th an SCR, ESP, and Wet FGD  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP) - wet flue gas desulfurization (FGD) combination or a spray dyer absorber 8212 fabric filter (SDA-FF) combination. In this program CONSOL is determining ...

2005-11-28T23:59:59.000Z

314

Mercury Measurements Characterizing the Impact of SCR on Mercury: Consol Site 7 - Eastern Bituminous Coal-Fired Power Plant with an SCR, ESP, and Wet FGD  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP) - wet flue gas desulfurization (FGD) combination or a spray dyer absorber fabric filter (SDA-FF) combination. In this program CONSOL is determining mercu...

2006-07-26T23:59:59.000Z

315

Mercury Measurements Characterizing the Impact of SCR on Mercury: Consol Test Site 4 - Eastern Bituminous Coal-Fired Power Plant wit h an SCR, ESP, and Wet FGD  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP) - wet flue gas desulfurization (FGD) combination or a spray dyer absorber fabric filter (SDA-FF) combination. In this program CONSOL is determining mercu...

2006-07-31T23:59:59.000Z

316

Mercury Measurements Characterizing the Impact of SCR on Mercury: Consol Site 6 - Eastern Bituminous Coal-Fired Power Plant with an SCR, ESP, and Wet FGD  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP) - wet flue gas desulfurization (FGD) combination or a spray dyer absorber 8211 fabric filter (SDA-FF) combination. In this program CONSOL is determining ...

2006-07-31T23:59:59.000Z

317

Engineering development of advanced coal-fired low-emission boiler systems. Technical progress report No. 15, April 15 1996--June 1996  

SciTech Connect

The Pittsburgh Energy Technology center of the US Department of Energy (DOE) has contracted with Combustion Engineering; Inc. (ABB CE) to perform work on the {open_quotes}Engineering Development of Advanced Coal-Fired Low-Emission Boiler Systems{close_quote} Project and has authorized ABB CE to complete Phase I on a cost-reimbursable basis and Phases II and III on a cost-share basis.

1996-08-19T23:59:59.000Z

318

Bench-scale Development of an Advanced Solid sorbent-based CO2 Capture Process for Coal-fired Power Plalnts  

NLE Websites -- All DOE Office Websites (Extended Search)

scale Development of an scale Development of an Advanced Solid Sorbent-based CO 2 Capture Process for Coal-fired Power Plants Background The mission of the U.S. Department of Energy/National Energy Technology Laboratory (DOE/NETL) Existing Plants, Emissions, & Capture (EPEC) Research & Development (R&D) Program is to develop innovative environmental control technologies to enable full use of the nation's vast coal reserves, while at the same time allowing the current

319

Thermal Integration of CO{sub 2} Compression Processes with Coal-Fired Power Plants Equipped with Carbon Capture  

SciTech Connect

Coal-fired power plants, equipped either with oxycombustion or post-combustion CO{sub 2} capture, will require a CO{sub 2} compression system to increase the pressure of the CO{sub 2} to the level needed for sequestration. Most analyses show that CO{sub 2} compression will have a significant effect on parasitic load, will be a major capital cost, and will contribute significantly to reduced unit efficiency. This project used first principle engineering analyses and computer simulations to determine the effects of utilizing compressor waste heat to improve power plant efficiency and increase net power output of coal-fired power plants with carbon capture. This was done for units with post combustion solvent-based CO{sub 2} capture systems and for oxyfired power plants, firing bituminous, PRB and lignite coals. The thermal integration opportunities analyzed for oxycombustion capture are use of compressor waste heat to reheat recirculated flue gas, preheat boiler feedwater and predry high-moisture coals prior to pulverizing the coal. Among the thermal integration opportunities analyzed for post combustion capture systems are use of compressor waste heat and heat recovered from the stripper condenser to regenerate post-combustion CO{sub 2} capture solvent, preheat boiler feedwater and predry high-moisture coals. The overall conclusion from the oxyfuel simulations is that thermal integration of compressor heat has the potential to improve net unit heat rate by up to 8.4 percent, but the actual magnitude of the improvement will depend on the type of heat sink used and to a lesser extent, compressor design and coal rank. The simulations of a unit with a MEA post combustion capture system showed that thermal integration of either compressor heat or stripper condenser heat to preheat boiler feedwater would result in heat rate improvements from 1.20 percent to 4.19 percent. The MEA capture simulations further showed that partial drying of low rank coals, done in combination with feedwater heating, would result in heat rate reductions of 7.43 percent for PRB coal and 10.45 percent for lignite.

Edward Levy

2012-06-29T23:59:59.000Z

320

Evaluation of BOC'S Lotox Process for the Oxidation of Elemental Mercury in Flue Gas from a Coal-Fired Boiler  

SciTech Connect

Linde's Low Temperature Oxidation (LoTOx{trademark}) process has been demonstrated successfully to remove more than 90% of the NOx emitted from coal-fired boilers. Preliminary findings have shown that the LoTOx{trademark} process can be as effective for mercury emissions control as well. In the LoTOx{trademark} system, ozone is injected into a reaction duct, where NO and NO{sub 2} in the flue gas are selectively oxidized at relatively low temperatures and converted to higher nitrogen oxides, which are highly water soluble. Elemental mercury in the flue gas also reacts with ozone to form oxidized mercury, which unlike elemental mercury is water-soluble. Nitrogen oxides and oxidized mercury in the reaction duct and residual ozone, if any, are effectively removed in a wet scrubber. Thus, LoTOx{trademark} appears to be a viable technology for multi-pollutant emission control. To prove the feasibility of mercury oxidation with ozone in support of marketing LoTOx{trademark} for multi-pollutant emission control, Linde has performed a series of bench-scale tests with simulated flue gas streams. However, in order to enable Linde to evaluate the performance of the process with a flue gas stream that is more representative of a coal-fired boiler; one of Linde's bench-scale LoTOx{trademark} units was installed at WRI's combustion test facility (CTF), where a slipstream of flue gas from the CTF was treated. The degree of mercury and NOx oxidation taking place in the LoTOx{trademark} unit was quantified as a function of ozone injection rates, reactor temperatures, residence time, and ranks of coals. The overall conclusions from these tests are: (1) over 80% reduction in elemental mercury and over 90% reduction of NOx can be achieved with an O{sub 3}/NO{sub X} molar ratio of less than two, (2) in most of the cases, a lower reactor temperature is preferred over a higher temperature due to ozone dissociation, however, the combination of both low residence time and high temperature proved to be effective in the oxidation of both NOx and elemental mercury, and (3) higher residence time, lower temperature, and higher molar ratio of O{sub 3}/NOx contributed to the highest elemental mercury and NOx reductions.

Khalid Omar

2008-04-30T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Jordan F. Clark Ira Leifer Libe Washburn Bruce P. Luyendyk  

E-Print Network (OSTI)

in natural gas bubble plumes: observations from the Coal Oil Point marine hydrocarbon seep field Received: 22 Detailed measurements of bubble composition, dissolved gas concentrations, and plume dynamics wereORIGINAL Jordan F. Clark ? Ira Leifer ? Libe Washburn Bruce P. Luyendyk Compositional changes

Luyendyk, Bruce

322

On-Line Monitoring Plant Performance Applications at Bruce Power  

Science Conference Proceedings (OSTI)

This report describes a pilot application to develop an on-line monitoring (OLM) program for eight units at the Bruce Power nuclear power facility in Tiverton, Ontario, Canada. The ongoing pilot project, the implementation of which began in April 2011, ...

2012-10-25T23:59:59.000Z

323

Quantifying effects of ramp metering on freeway safety , Bruce Hellingab,*  

E-Print Network (OSTI)

Quantifying effects of ramp metering on freeway safety Chris Leea , Bruce Hellingab,* , Kaan Ozbayc model and uses this model to investigate the effect of the local traffic-responsive ramp metering strategy on freeway safety. Safety benefits of ramp metering are quantified in terms of the reduced crash

Hellinga, Bruce

324

Control of Sulfur Dioxide Emissions from Pulverized Coal-Fired Boilers by Dry Removal with Lime and Limestone Sorbants  

E-Print Network (OSTI)

Over the past decade increasing concern over the potential environmental impact associated with the emissions of both gaseous and particulate pollutants has resulted in the promulgation of strict regulatory standards governing such emissions. In this regard, particular attention has been placed upon the control of sulfur dioxide (SO2) from major fuel burning installations. The provisions of the 1977 Amendments to the Clean Air Act which relate to the Prevention of Significant Deterioration (PSD) and the New Source Performance Standards (NSPS) have made consideration of this problem of significant additional importance in the context of increased coal utilization. There exist three general methods for the control of sulfur dioxide emissions from pulverized coal-fired boiler equipment. These are: (1) coal cleaning to remove pyritic sulfur, (2) conventional wet, nonregenerable scrubbing with alkaline slurry and solution processes, and (3) dry processes which involve direct introduction of lime or limestone into the firebox, or a spray dryer operated with nonregenerable alkaline sorbents coupled with a fabric filter collector. Equipment requirements, SO2 removal criteria, general economics, and potential applications of these latter two approaches within category (3) will be discussed.

Schwartz, M. H.

1979-01-01T23:59:59.000Z

325

Coal-fired power-plant-capital-cost estimates. Final report. [Mid-1978 price level; 13 different sites  

Science Conference Proceedings (OSTI)

Conceptual designs and order-of-magnitude capital cost estimates have been prepared for typical 1000-MW coal-fired power plants. These subcritical plants will provide high efficiency in base load operation without excessive efficiency loss in cycling operation. In addition, an alternative supercritical design and a cost estimate were developed for each of the plants for maximum efficiency at 80 to 100% of design capacity. The power plants will be located in 13 representative regions of the United States and will be fueled by coal typically available in each region. In two locations, alternate coals are available and plants have been designed and estimated for both coals resulting in a total of 15 power plants. The capital cost estimates are at mid-1978 price level with no escalation and are based on the contractor's current construction projects. Conservative estimating parameters have been used to ensure their suitability as planning tools for utility companies. A flue gas desulfurization (FGD) system has been included for each plant to reflect the requirements of the promulgated New Source Performance Standards (NSPS) for sulfur dioxide (SO/sub 2/) emissions. The estimated costs of the FGD facilities range from 74 to 169 $/kW depending on the coal characteristics and the location of the plant. The estimated total capital requirements for twin 500-MW units vary from 8088 $/kW for a southeastern plant burning bituminous Kentucky coal to 990 $/kW for a remote western plant burning subbituminous Wyoming coal.

Holstein, R.A.

1981-05-01T23:59:59.000Z

326

Superheater/intermediate temperature airheater tube corrosion tests in the MHD Coal Fired Flow Facility (Eastern Coal Phase)  

DOE Green Energy (OSTI)

Corrosion data have been obtained for tub is exposed for 1500--2000 hours in a proof-of-concept magnetohydrodynamics (MHD) power generation test facility to conditions representative of superheater and intermediate temperature air heater (ITAH) components. The tubes, coated with K{sub 2}SO{sub 4}-rich deposits, were corroded more than in most pulverized coal fired superheater service, but much less than the highly aggressive liquid phase attack encountered in conventional plants with certain coals and temperatures. Results indicated that, with parabolic corrosion kinetics, type 310 and 253MA stainless steels should be usable to 1400F at hot end of ITAH. At final superheater temperatures, 2.25 and 5 Cr steels were indicated to have parabolic corrosion rates generally below a 0.5 mm/yr criterion, based on corrosion scale thickness. However, unknown amounts of scale loss from spallation made this determination uncertain. Stainless steels 304H, 316H, and 321H had parabolic rates variably above the criterion, but may be servicable under less cyclic conditions. Corrosion rates derived from scale thickness and intergranular corrosion depth measurements are reported, along with scale morphologies and compositions. Implications of results on commercial MHD utilization of the alloys are discussed, as well as the indicated need for more corrosion resistant alloys or coatings under the most severe exposure conditions.

White, M.K.

1993-11-01T23:59:59.000Z

327

Economic Analysis of the Environmental Effects of the Coal-Fired Electric Generator at Boardman, Oregon. Final Report.  

SciTech Connect

This study is one of several commissioned by the Bonneville Power Administration (BPA) to estimate the economic value of the environmental costs and benefits of different electricity-generating resources. In it we described and quantify the environmental costs and benefits of coal-fired generators, using the plant in Boardman, Oregon, as the basis for our estimations. The Boardman plant uses pulverized coal to produce steam for generating electricity. It is nominally rated at 550 megawatts. This study assumes a 70% load factor and an annual production of 3373 x 10/sup 6/ kWh. Cooling water comes from a 1400-acre cooling pond; coal comes from Wyoming in 100-car unit-trains every two days. The estimated service life of the plant is 40 years. We developed a socioeconomic-environmental model to assess the final physical impacts of each of the initial impacts resulting from the fuel cycle. The analysis of environmental effects comprises four steps: (1) identify all the potential environmental impacts stemming from the entire fuel cycle associated with the plant; (2) determine which effects warrant detailed economic analysis; (3) complete the economic analysis for the effects selected in step 2; and (4) estimate the extent to which the results of the case study apply to other potential plants using the coal-fuel cycle. 102 references, 5 figures, 10 tables.

United States. Bonneville Power Administration.

1983-12-29T23:59:59.000Z

328

Projections of air toxic emissions from coal-fired utility combustion: Input for hazardous air pollutant regulators  

Science Conference Proceedings (OSTI)

The US Environmental Protection Agency (EPA) is required by the 1990 CAAA to promulgate rules for all ``major`` sources of any of these HAPs. According to the HAPs section of the new Title III, any stationary source emitting 10 tons per year (TPY) of one HAP or 25 TPY of a combination of HAPs will be considered and designated a major source. In contrast to the original National Emission Standards for Hazardous Air Pollutants (NESHAP), which were designed to protect public health to ``an ample margin of safety,`` the new Title III, in its first phase, will regulate by industrial category those sources emitting HAPs in excess of the 10/25-TPY threshold levels, regardless of health risks. The trace elements normally associated with coal mineral matter and the various compounds formed during coal combustion have the potential to produce hazardous air toxic emissions from coal-fired electric utilities. Under Title III, the EPA is required to perform certain studies, prior to any regulation of electric utilities; these studies are currently underway. Also, the US Department of Energy (DOE) maintains a vested interest in addressing those energy policy questions affecting electric utility generation, coal mining, and steel producing critical to this country`s economic well-being, where balancing the costs to the producers and users of energy with the benefits of environmental protection to the workers and the general populace remains of significant concern.

Szpunar, C.B.

1993-08-01T23:59:59.000Z

329

Optical fiber evanescent wave adsorption sensors for high-temperature gas sensing in advanced coal-fired power plants  

Science Conference Proceedings (OSTI)

Modern advanced energy systems such as coal-fired power plants, gasifiers, or similar infrastructure present some of the most challenging harsh environments for sensors. The power industry would benefit from new, ultra-high temperature devices capable of surviving in hot and corrosive environments for embedded sensing at the highest value locations. For these applications, we are currently exploring optical fiber evanescent wave absorption spectroscopy (EWAS) based sensors consisting of high temperature core materials integrated with novel high temperature gas sensitive cladding materials. Mathematical simulations can be used to assist in sensor development efforts, and we describe a simulation code that assumes a single thick cladding layer with gas sensitive optical constants. Recent work has demonstrated that Au nanoparticle-incorporated metal oxides show a potentially useful response for high temperature optical gas sensing applications through the sensitivity of the localized surface plasmon resonance absorption peak to ambient atmospheric conditions. Hence, the simulation code has been applied to understand how such a response can be exploited in an optical fiber based EWAS sensor configuration. We demonstrate that interrogation can be used to optimize the sensing response in such materials.

Buric, M.; Ohodnicky, P.; Duy, J.

2012-01-01T23:59:59.000Z

330

Low Cost Sorbent for Capturing CO{sub 2} Emissions Generated by Existing Coal-fired Power Plants  

SciTech Connect

TDA Research, Inc. has developed a novel sorbent based post-combustion CO{sub 2} removal technology. This low cost sorbent can be regenerated with low-pressure (ca. 1 atm) superheated steam without temperature swing or pressure-swing. The isothermal and isobaric operation is a unique and advantageous feature of this process. The objective of this project was to demonstrate the technical and economic merit of this sorbent based CO{sub 2} capture approach. Through laboratory, bench-scale and field testing we demonstrated that this technology can effectively and efficiently capture CO{sub 2} produced at an existing pulverized coal power plants. TDA Research, Inc is developing both the solid sorbent and the process designed around that material. This project addresses the DOE Program Goal to develop a capture technology that can be added to an existing or new coal fired power plant, and can capture 90% of the CO{sub 2} produced with the lowest possible increase in the cost of energy. .

Elliott, Jeannine

2013-08-31T23:59:59.000Z

331

paper CO2 Regulations and Electricity Prices: Cost Estimates for Coal-Fired Power Plants. We thank  

E-Print Network (OSTI)

For fossil fuel power plants to be built in the future, carbon capture and storage (CCS) technologies offer the potential for significant reductions in CO2 emissions. We examine the break-even value for CCS adoptions, that is, the critical value in the charge for CO2 emissions that would justify investment in CCS capabilities. Our analysis takes explicitly into account that the supply of electricity at the wholesale level (generation) is organized competitively in some U.S. jurisdictions, while in others a regulated utility provides integrated generation and distribution services. For either market structure, we find that emissions charges in the range of $25-$30 per tonne of CO2 would be the break-even value for adopting CCS capabilities at new coal-fired power plants. The corresponding break-even values for natural gas plants are substantially higher, near $60 per tonne. Our break-even estimates serve as a basis for projecting the change in electricity prices once carbon emissions become costly. CCS capabilities effectively put an upper bound on the rise in electricity prices. We estimate this bound to be near 30 % at the retail level for both coal and natural gas plants. In contrast to the competitive power supply scenario, however, these price increases materialize only gradually for a regulated utility. The delay in price adjustments reflects that for regulated

Stefan Reichelstein; Erica Plambeck

2009-01-01T23:59:59.000Z

332

Dr. Bruce L. Chrisman Chief Operating Officer Fermilab  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Bruce L. Chrisman Bruce L. Chrisman Chief Operating Officer Fermilab P.O. Box 500 Batavia, IL 60510 Dear Dr. Chrisman: SUBJECT: NATIONAL ENVIRONMENTAL POLICY ACT (NEPA) DETERMINATION AT FERMI NATIONAL ACCELERATOR LABORATORY (FERMILAB) - FERMILAB MUON CAMPUS, INCLUDING THE MUON TO ELECTRON CONVERSION (Mute) EXPERIMENT AND THE MC-1 BUILDING Reference: Letter, from B. Chrisman to M. Weis, dated June 6, 2012, Subject: NEPA Environmental Evaluation Notification Form (EENF) for the Fermilab Muon Campus, including the Mute Experiment and the MC-1 Building have reviewed the Fermilab EENF for the Fermilab Muon Campus, including the Mute Experiment and the MC-1 Building. Based on the information provided in the EENF, I have approved the following categorical exclusion (CX): Project Name Approved CX

333

Dr, Bruce L. Chrisman Chief Operating Officer F~rmilab  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Dr, Bruce L. Chrisman Dr, Bruce L. Chrisman Chief Operating Officer F~rmilab P.O. Box 500 Batavia, IL 60510 Dear Dr. Chrisman: SUBJECT": NATIONAL ENVIRQNMENTAL POLICY ACT (NEPI~) DETERMINATION .~T FERMI N,4TIONAL ACCELERATOR LABORATORY (FERMILAB~ - 35 TOE( LIQUID ARGON PROTOTYPE DETECTOR Reference: Letter, from B. Chrisman to M. Weis, dated Aprif 11, 2012, Subject: National Environmental Policy Act (NEPA) Environmental Evaluation Notification Forrri (EENF) for the 35 Ton Liquid Argon Prototype Detector have reviewed the Fermilab EENF for the 35 Ton Liquid Argon Prototype Detector. Based on the information provided in the EENF, I have approved the following categorical exclusion (CX): Project Name 35 Ton Liquid Argon Detector Approved CX 4/12/207 2 B3.6 am returning a signed copy of the EENF for your records. No further ~IEPA review is required.

334

Bruce Held visits Y-12 National Security Complex | National Nuclear  

National Nuclear Security Administration (NNSA)

Held visits Y-12 National Security Complex | National Nuclear Held visits Y-12 National Security Complex | National Nuclear Security Administration Our Mission Managing the Stockpile Preventing Proliferation Powering the Nuclear Navy Emergency Response Recapitalizing Our Infrastructure Continuing Management Reform Countering Nuclear Terrorism About Us Our Programs Our History Who We Are Our Leadership Our Locations Budget Our Operations Media Room Congressional Testimony Fact Sheets Newsletters Press Releases Speeches Events Social Media Video Gallery Photo Gallery NNSA Archive Federal Employment Apply for Our Jobs Our Jobs Working at NNSA Blog Home > NNSA Blog > Bruce Held visits Y-12 National Security Complex Bruce Held visits Y-12 National Security Complex Posted By Office of Public Affairs Acting NNSA Administrator and Acting Undersecretary for Nuclear Security

335

On-Line Monitoring Plant Performance Applications at Bruce Power  

Science Conference Proceedings (OSTI)

On-line monitoring (OLM) and advanced pattern recognition (APR) capabilities have advanced significantly over the past few years. Many utilities now have basic or advanced applications available within plants and across generating fleets. However, the effective use and integration of these capabilities into established plant reliability processes are still minimal. This OLM applications pilot project was implemented in April 2011 at the Bruce Power Nuclear Generating facility in Tiverton, Ontario, Canada...

2012-01-23T23:59:59.000Z

336

Superheater/intermediate temperature air heater tube corrosion tests in the MHD coal fired flow facility (Montana Rosebud POC tests)  

DOE Green Energy (OSTI)

Nineteen alloys have been exposed for approximately 1000 test hours as candidate superheater and intermediate temperature air heater tubes in a U.S. DOE facility dedicated to demonstrating Proof of Concept for the bottoming or heat and seed recovery portion of coal fired magnetohydrodynamic (MHD) electrical power generating plants. Corrosion data have been obtained from a test series utilizing a western United States sub-bituminous coal, Montana Rosebud. The test alloys included a broad range of compositions ranging from carbon steel to austenitic stainless steels to high chromium nickel-base alloys. The tubes, coated with K{sub 2}SO-containing deposits, developed principally, oxide scales by an oxidation/sulfidation mechanism. In addition to being generally porous, these scales were frequently spalled and/or non-compact due to a dispersed form of outward growth by oxide precipitation in the adjacent deposit. Austenitic alloys generally had internal penetration as trans Tranular and/or intergranular oxides and sulfides. While only two of the alloys had damage visible without magnification as a result of the relatively short exposure, there was some concern about Iona-term corrosion performance owing to the relatively poor quality scales formed. Comparison of data from these tests to those from a prior series of tests with Illinois No. 6, a high sulfur bituminous coal, showed less corrosion in the present test series with the lower sulfur coal. Although K{sub 2}SO{sub 4}was the principal corrosive agent as the supplier of sulfur, which acted to degrade alloy surface scales, tying up sulfur as K{sub 2}SO{sub 4} prevented the occurrence of complex alkali iron trisulfates responsible for severe or catastrophic corrosion in conventional power plants with certain coals and metal temperatures.

White, M.

1996-01-01T23:59:59.000Z

337

Alstom's Chemical Looping Combustion Prototype for CO{sub 2} Capture from Existing Pulverized Coal-Fired Power Plants  

SciTech Connect

Alstoms Limestone Chemical Looping (LCL) process has the potential to capture CO{sub 2} from new and existing coal-fired power plants while maintaining high plant power generation efficiency. This new power plant concept is based on a hybrid combustion- gasification process utilizing high temperature chemical and thermal looping technology. This process could also be potentially configured as a hybrid combustion-gasification process producing a syngas or hydrogen for various applications while also producing a separate stream of CO{sub 2} for use or sequestration. The targets set for this technology is to capture over 90% of the total carbon in the coal at cost of electricity which is less than 20% greater than Conventional PC or CFB units. Previous work with bench scale test and a 65 kWt Process Development Unit Development (PDU) has validated the chemistry required for the chemical looping process and provided for the investigation of the solids transport mechanisms and design requirements. The objective of this project is to continue development of the combustion option of chemical looping (LCL-C) by designing, building and testing a 3 MWt prototype facility. The prototype includes all of the equipment that is required to operate the chemical looping plant in a fully integrated manner with all major systems in service. Data from the design, construction, and testing will be used to characterize environmental performance, identify and address technical risks, reassess commercial plant economics, and develop design information for a demonstration plant planned to follow the proposed Prototype. A cold flow model of the prototype will be used to predict operating conditions for the prototype and help in operator training. Operation of the prototype will provide operator experience with this new technology and performance data of the LCL-C process, which will be applied to the commercial design and economics and plan for a future demonstration plant.

Andrus, Herbert; Chiu, John; Edberg, Carl; Thibeault, Paul; Turek, David

2012-09-30T23:59:59.000Z

338

A coal-fired combustion system for industrial process heating applications. Quarterly technical progress report, July 1993--September 1993  

SciTech Connect

This advanced combustion system research program is for the development of innovative coal-fired process heaters which can be used for high temperature melting, smelting and waste vitrification processes. The process heater systems to be developed have multiple use applications; however, the Phase 3 research effort is being focused on the development of a process heater system to be used for producing value added vitrified glass products from boiler/incinerator ashes and industrial wastes. The primary objective of the Phase 3 project is to develop and integrate all the system components, from fuel through total system controls, and then test the complete system in order to evaluate its potential marketability. During the past quarter, the major effort was completing some of the system modification installation designs, completing industry funded testing, developing a surrogate TSCA ash composition, and completing the TSCA ash Test Plan. The installation designs will be used for the equipment modifications planned for the end of CY 93. The industry funded testing consisted of vitrifying Spent Aluminum Potliner (SPL) which is a listed hazardous waste. This testing has verified that SPL can be vitrified into a safe, recyclable glass product. Some results from this testing are provided in Section 2.2.1. The surrogate TSCA ash composition was developed with input from various DOE laboratories and subcontractors. The surrogate ash consists of a mixture of MSW fly ash and bottom ash spiked with heavy metal contaminants. The levels of metal additives are sufficient to ascertain the partitioning of the contaminants between the glass and effluent flow streams. Details of the surrogate composition and the planned testing is provided in Section 4.2.2.

Not Available

1993-10-30T23:59:59.000Z

339

Engineering development of advanced coal-fired low-emission boiler systems. Technical progress report No. 11, April 1995--June 1995  

Science Conference Proceedings (OSTI)

The Pittsburgh Energy Technology Center of the U.S. Department of Energy (DOE) has contracted with Combustion Engineering, Inc. (ABB CE) to perform work on the {open_quotes}Engineering Development of Advanced Coal-Fired Low-Emission Boiler Systems{close_quotes} Project and has authorized ABB CE to complete Phase I on a cost-reimbursable basis and Phases II and III on a cost-share basis. The overall objective of the Project is the expedited commercialization of advanced coal-fired low-emission boiler systems. The specified primary objectives are: (1) NO{sub x} emissions not greater than one-third NSPS. (2) SO{sub x} emissions not greater than one-third NSPS. (3) Particulate emissions not greater than one-half NSPS. The specific secondary objectives are: (1) Improved ash disposability and reduced waste generation. (2) Reduced air toxics emissions. (3) Increased generating efficiency. The final deliverables are a design data base that will allow future coal-fired power plants to meet the stated objectives and a preliminary design of a Commercial Generation Unit. The work in Phase I covered a 24-month period and included system analysis, RD&T Plan formulation, component definition, and preliminary Commercial Generating Unit (CGU) design. Phase II will cover a 15-month period and will include preliminary Proof-of-Concept Test Facility (POCTF) design and subsystem testing. Phase III will cover a 9-month period and will produce a revised CGU design and a revised POCTF design, cost estimate and a test plan. Phase IV, the final Phase, will cover a 36-month period and will include POCTF detailed design, construction, testing, and evaluation.

NONE

1995-08-30T23:59:59.000Z

340

Development of a high-performance coal-fired power generating system with pyrolysis gas and char-fired high temperature furnace (HITAF). Volume 1, Final report  

SciTech Connect

A major objective of the coal-fired high performance power systems (HIPPS) program is to achieve significant increases in the thermodynamic efficiency of coal use for electric power generation. Through increased efficiency, all airborne emissions can be decreased, including emissions of carbon dioxide. High Performance power systems as defined for this program are coal-fired, high efficiency systems where the combustion products from coal do not contact the gas turbine. Typically, this type of a system will involve some indirect heating of gas turbine inlet air and then topping combustion with a cleaner fuel. The topping combustion fuel can be natural gas or another relatively clean fuel. Fuel gas derived from coal is an acceptable fuel for the topping combustion. The ultimate goal for HIPPS is to, have a system that has 95 percent of its heat input from coal. Interim systems that have at least 65 percent heat input from coal are acceptable, but these systems are required to have a clear development path to a system that is 95 percent coal-fired. A three phase program has been planned for the development of HIPPS. Phase 1, reported herein, includes the development of a conceptual design for a commercial plant. Technical and economic feasibility have been analysed for this plant. Preliminary R&D on some aspects of the system were also done in Phase 1, and a Research, Development and Test plan was developed for Phase 2. Work in Phase 2 include s the testing and analysis that is required to develop the technology base for a prototype plant. This work includes pilot plant testing at a scale of around 50 MMBtu/hr heat input. The culmination of the Phase 2 effort will be a site-specific design and test plan for a prototype plant. Phase 3 is the construction and testing of this plant.

NONE

1996-02-01T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Characterization of open-cycle, coal-fired MHD generators. Ninth-tenth quarterly technical progress report, July 1, 1978-April 30, 1979  

DOE Green Energy (OSTI)

The successful design of full-scale open-cycle, coal-fired MHD generators for baseload electrical production requires a detailed understanding of the plasma chemical and plasma dynamic characteristics of anticipated combustor and channel fluids. This report documents progress in efforts to model negative ion formation and slag condensation effects on core flow conductivity, to improve the ability to sample and characterize laboratory produced coal combustion plasmas, and to measure mechanisms and rates of slag oxide condensation. A set of parametric calculations showing the influence of various input parameters on a nominal full-scale, supersonic generator system is also presented.

Kolb, C.E.; Wormhoudt, J.; Yousefian, V.; Cheng, W.; Bien, F.; Martinez-Sanchez, M.; Silver, J.

1979-05-01T23:59:59.000Z

342

Evaluation of technical feasibility of closed-cycle non-equilibrium MHD power generation with direct coal firing. Final report, Task I  

DOE Green Energy (OSTI)

Program accomplishments in a continuing effort to demonstrate the feasibility of direct coal-fired, closed-cycle MHD power generation are reported. This volume contains the following appendices: (A) user's manual for 2-dimensional MHD generator code (2DEM); (B) performance estimates for a nominal 30 MW argon segmented heater; (C) the feedwater cooled Brayton cycle; (D) application of CCMHD in an industrial cogeneration environment; (E) preliminary design for shell and tube primary heat exchanger; and (F) plant efficiency as a function of output power for open and closed cycle MHD power plants. (WHK)

Not Available

1981-11-01T23:59:59.000Z

343

Characterization of open-cycle, coal-fired MHD generators. Seventh-eighth quarterly technical progress report, January 1-June 30, 1978  

DOE Green Energy (OSTI)

The successful design of full-scale open-cycle, coal-fired MHD generators for baseload electrical production requires a detailed understanding of the plasma chemical and plasma dynamic characteristics of anticipated combustor and channel fluids. This report documents progress in efforts to model negative ion formation and slag condensation effects on core flow conductivity, to improve the ability to sample and characterize laboratory produced coal combustion plasmas, and to define a mathematical model of the diffuse discharge plasma sheath in the anode boundary layer.

Kolb, C.E.; Elgin, J.B.; Wormhoudt, J.; Yousefian, V.; Martinez-Sanchez, M.; Dvore, D.

1978-07-01T23:59:59.000Z

344

Application of pulse spark discharges for scale prevention and continuous filtration methods in coal-fired power plant Oct. 1, 2008 … Sept. 30, 2011  

NLE Websites -- All DOE Office Websites (Extended Search)

Drexel University Drexel University Y. Cho, A. Fridman, and A. Starikovskii Oct. 28, 2008 Application of pulse spark discharges for scale prevention and continuous filtration methods in coal-fired power plant U.S. DEPARTMENT OF ENERGY National Energy Technology Laboratory New Scale-Prevention Technology Use electrical pulse spark discharges in water to precipitate dissolved mineral ions. Remove them using a self-cleaning filter from cooling water. Specific objectives of the proposed work 1. Determine whether the spark discharge can promote the precipitation of mineral ions in cooling water. 2. Determine whether the proposed technology can increase the COC through a continuous precipitation of calcium ions

345

Il fenomeno dei fan nel mercato della musica. Analisi netnografica dei seguaci italiani di Bruce Springsteen.  

E-Print Network (OSTI)

??Lo studio ha ad oggetto la comunit dei fan italiani di Bruce Springsteen. Dopo aver analizzato la letteratura e descritto il fenomeno dei fan e (more)

Gallo, Sara

2007-01-01T23:59:59.000Z

346

Development of a Low NOx Burner System for Coal Fired Power Plants Using Coal and Biomass Blends  

E-Print Network (OSTI)

The low NOx burner (LNB) is the most cost effective technology used in coal-fired power plants to reduce NOx. Conventional (unstaged) burners use primary air for transporting particles and swirling secondary air to create recirculation of hot gases. LNB uses staged air (dividing total air into primary, secondary and tertiary air) to control fuel bound nitrogen from mixing early and oxidizing to NOx; it can also limit thermal NOx by reducing peak flame temperatures. Previous research at Texas A&M University (TAMU) demonstrated that cofiring coal with feedlot biomass (FB) in conventional burners produced lower or similar levels of NOx but increased CO. The present research deals with i) construction of a small scale 29.31 kW (100,000 BTU/hr) LNB facility, ii) evaluation of firing Wyoming (WYO) coal as the base case coal and cofiring WYO and dairy biomass (DB) blends, and iii) evaluating the effects of staging on NOx and CO. Ultimate and Proximate analysis revealed that WYO and low ash, partially composted, dairy biomass (LA-PC-DB-SepS) had the following heat values and empirical formulas: CH0.6992N0.0122O0.1822S0.00217 and CH_1.2554N_0.0470O_0.3965S_0.00457. The WYO contained 3.10 kg of Ash/GJ, 15.66 kg of VM/GJ, 0.36 kg of N/GJ, and 6.21 kg of O/GJ while LA-PC-DB-SepS contained 11.57 kg of Ash/GJ, 36.50 kg of VM/GJ, 1.50 kg of N/GJ, and 14.48 kg of O/GJ. The construction of a LNB nozzle capable of providing primary, swirled secondary and swirled tertiary air for staging was completed. The reactor provides a maximum residence time of 1.8 seconds under hot flow conditions. WYO and DB were blended on a mass basis for the following blends: 95:5, 90:10, 85:15, and 80:20. Results from firing pure WYO showed that air staging caused a slight decrease of NOx in lean regions (equivalence ratio, greater than or equal to 1.0) but an increase of CO in rich regions (=1.2). For unstaged combustion, cofiring resulted in most fuel blends showing similar NOx emissions to WYO. Staged cofiring resulted in a 12% NOx increase in rich regions while producing similar to slightly lower amounts of NOx in lean regions. One conclusion is that there exists a strong inverse relationship between NOx and CO emissions.

Gomez, Patsky O.

2009-05-01T23:59:59.000Z

347

Measurements of the flame emissivity and radiative properties of particulate medium in pulverized-coal-fired boiler furnaces by image processing of visible radiation  

SciTech Connect

Due to the complicated processes for coal particles burning in industrial furnaces, their radiative properties, such as the absorption and scattering coefficients, which are essential to make reliable calculation of radiative transfer in combustion computation, are hard to be given exactly by the existing methods. In this paper, multiple color image detectors were used to capture approximately red, green, and blue monochromatic radiative intensity images in the visible wavelength region, and the flame emissivity and the radiative properties of the particulate media in three pulverized-coal-fired boiler furnaces were got from the flame images. It was shown that as the load increased, the flame emissivity and the radiative properties increased too; these radiative parameters had the largest values near the burner zone, and decreased along the combustion process. Compared with the combustion medium with a low-volatile anthracite coal burning in a 670 t/h boiler, the emissivity and the absorption coefficient of the medium with a high-volatile bituminous coal burning in a 1025 t/h boiler were smaller near the outlet zone, but were larger near the burner zone of the furnace, due to the significant contribution of soot to the radiation. This work will be of practical importance in modeling and calculating the radiative heat transfer in combustion processes, and improving the technology for in situ, multi-dimensional visualization of large-scale combustion processes in coal-fired furnaces of power plants. 18 refs., 10 figs., 8 tabs.

Chun Lou; Huai-Chun Zhou; Peng-Feng Yu; Zhi-Wei Jiang [Huazhong University of Science and Technology, Wuhan (China). State Key Laboratory of Coal Combustion

2007-07-01T23:59:59.000Z

348

Micronized coal-fired retrofit system for SO{sub x} reduction Krakow clean fossil fuels and energy efficiency program. Final report  

SciTech Connect

This report describes results of a technical, financial and environmental assessment study for a project, which would have included a new TCS micronized coal-fired heating plant for the Produkcja I Hodowla Roslin Ogrodniczych (PHRO) Greenhouse Complex; Krzeszowice, Poland. Project site is about 20 miles west of Krakow, Poland. During the project study period, PHRO utilized 14 heavy oil-fired boilers to produce heat for its greenhouse facilities and also home heating to several adjacent apartment housing complexes. The boilers burn a high-sulfur content heavy crude oil, called mazute, The project study was conducted during a period extended from March 1996 through February 1997. For size orientation, the PHRO Greenhouse complex grows a variety of vegetables and flowers for the Southern Poland marketplace. The greenhouse area under glass is very large and equivalent to approximately 50 football fields, The new micronized coal fired boiler would have: (1) provided a significant portion of the heat for PHRO and a portion of the adjacent apartment housing complexes, (2) dramatically reduced sulfur dioxide air pollution emissions, while satisfying new Polish air regulations, and (3) provided attractive savings to PHRO, based on the quantity of displaced oil.

1997-04-01T23:59:59.000Z

349

Evaluation of technical feasibility of closed-cycle non-equilibrium MHD power generation with direct coal firing. Final report, Task 1  

DOE Green Energy (OSTI)

Program accomplishments in a continuing effort to demonstrate the feasibility of direct coal fired, closed cycle, magnetohydrodynamic power generation are detailed. These accomplishments relate to all system aspects of a CCMHD power generation system including coal combustion, heat transfer to the MHD working fluid, MHD power generation, heat and cesium seed recovery and overall systems analysis. Direct coal firing of the combined cycle has been under laboratory development in the form of a high slag rejection, regeneratively air cooled cyclone coal combustor concept, originated within this program. A hot bottom ceramic regenerative heat exchanger system was assembled and test fired with coal for the purposes of evaluating the catalytic effect of alumina on NO/sub x/ emission reduction and operability of the refractory dome support system. Design, procurement, fabrication and partial installation of a heat and seed recovery flow apparatus was accomplished and was based on a stream tube model of the full scale system using full scale temperatures, tube sizes, rates of temperature change and tube geometry. Systems analysis capability was substantially upgraded by the incorporation of a revised systems code, with emphasis on ease of operator interaction as well as separability of component subroutines. The updated code was used in the development of a new plant configuration, the Feedwater Cooled (FCB) Brayton Cycle, which is superior to the CCMHD/Steam cycle both in performance and cost. (WHK)

Not Available

1981-11-01T23:59:59.000Z

350

Engineering development of coal-fired high performance power systems, Phase 2 and 3. Quarterly progress report, October 1--December 31, 1995  

SciTech Connect

The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) by the year 2000 that is capable of: >47% thermal efficiency (HHV); NO{sub x}, SO{sub x} and particulates {ge} 10% NSPS; coal {ge} 65% of heat input; all solid wastes benign; and cost of electricity 90% of present plant. The HIPPS generating plant integrates a combustion gas turbine/HRSG combined cycle arrangement with an advanced coal-fired boiler. The unique feature of the HIPPS plant is the partial heating of gas turbine (GT) compressor outlet air using energy released by firing coal in the high temperature advanced furnace (HITAF). The compressed air is additionally heated prior to entering the GT expander section by burning natural gas. Energy available, in the gas turbine exhaust and in the HITAF flue gas are used in a steam cycle to maximize energy production. The HIPPS plant arrangement is thus a combination of existing technologies (gas turbine, heat recovery boilers, conventional steam cycle) and new technologies (the HITAF design especially the heater located in the radiant section). Work reported herein is from Task 1.3, HIPPS Commercial Design and Task 2.2, HITAF Air Heaters.

1995-12-31T23:59:59.000Z

351

Engineering development of advanced coal-fired low-emission boiler systems. Technical progress report No. 12, July--September 1995  

SciTech Connect

The overall objective of the Project is the expedited commercialization of advanced coal-fired low-emission boiler systems. The goals for emissions and plant efficiency are: NO{sub x} emissions not greater than 0.1 lb/million Btu; SO{sub x} emissions not greater than 0.1 lb/million Btu; particulate emissions not greater than 0.01 lb/million Btu; and net plant efficiency (HHV basis) not less than 42%. Other goals include: improved ash disposability and reduced waste generation; and reduced air toxics emissions. The final deliverables are a design data base that will allow future coal-fired power plants to meet the stated objectives, and a preliminary design of a Commercial Generation Unit. The work in Phase I covered a 24- month period and included system analysis, RD&T Plan formulation, component definition, and preliminary Commercial Generating Unit (CGU) design. Phase II will cover a 15-month period and will include preliminary Proof-of-Concept Test Facility (POCTF) design and subsystem testing. Phase III will cover a 9-month period and will produce a revised CGU design and a revised POCTF design, cost estimate and a test plan. Phase IV, the final Phase, will cover a 36- month period and will include POCTF detailed design, construction, testing, and evaluation.

NONE

1995-11-27T23:59:59.000Z

352

Internet Based, GIS Catalog of Non-Traditional Sources of Cooling Water for Use at America's Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

In recent years, rising populations and regional droughts have caused coal-fired power plants to temporarily curtail or cease production due to a lack of available water for cooling. In addition, concerns about the availability of adequate supplies of cooling water have resulted in cancellation of plans to build much-needed new power plants. These issues, coupled with concern over the possible impacts of global climate change, have caused industry and community planners to seek alternate sources of water to supplement or replace existing supplies. The Department of Energy, through the National Energy Technology Laboratory (NETL) is researching ways to reduce the water demands of coal-fired power plants. As part of the NETL Program, ALL Consulting developed an internet-based Catalog of potential alternative sources of cooling water. The Catalog identifies alternative sources of water, such as mine discharge water, oil and gas produced water, saline aquifers, and publicly owned treatment works (POTWs), which could be used to supplement or replace existing surface water sources. This report provides an overview of the Catalog, and examines the benefits and challenges of using these alternative water sources for cooling water.

J. Daniel Arthur

2011-09-30T23:59:59.000Z

353

HOG on a WIM Aaron Stafford Wayne Piekarski Bruce H. Thomas  

E-Print Network (OSTI)

HOG on a WIM Aaron Stafford Wayne Piekarski Bruce H. Thomas Wearable Computer Lab School-mail: aaron.stafford@unisa.edu.au e-mail: wayne.piekarski@unisa.edu.au e-mail: bruce display system as presented in Stafford et al. [10]. With a projector based display, objects such as hands

Thomas, Bruce

354

Novel polymer membrane process for pre-combustion CO{sub 2} capture from coal-fired syngas  

Science Conference Proceedings (OSTI)

This final report describes work conducted for the Department of Energy (DOE NETL) on development of a novel polymer membrane process for pre-combustion CO{sub 2} capture from coalfired syngas (award number DE-FE0001124). The work was conducted by Membrane Technology and Research, Inc. (MTR) from September 15, 2009, through December 14, 2011. Tetramer Technologies, LLC (Tetramer) was our subcontract partner on this project. The National Carbon Capture Center (NCCC) at Wilsonville, AL, provided access to syngas gasifier test facilities. The main objective of this project was to develop a cost-effective membrane process that could be used in the relatively near-term to capture CO{sub 2} from shifted syngas generated by a coal-fired Integrated Gasification Combined Cycle (IGCC) power plant. In this project, novel polymeric membranes (designated as Proteus membranes) with separation properties superior to conventional polymeric membranes were developed. Hydrogen permeance of up to 800 gpu and H{sub 2}/CO{sub 2} selectivity of >12 was achieved using a simulated syngas mixture at 150C and 50 psig, which exceeds the original project targets of 200 gpu for hydrogen permeance and 10 for H{sub 2}/CO{sub 2} selectivity. Lab-scale Proteus membrane modules (with a membrane area of 0.13 m{sup 2}) were also developed using scaled-up Proteus membranes and high temperature stable module components identified during this project. A mixed-gas hydrogen permeance of about 160 gpu and H{sub 2}/CO{sub 2} selectivity of >12 was achieved using a simulated syngas mixture at 150C and 100 psig. We believe that a significant improvement in the membrane and module performance is likely with additional development work. Both Proteus membranes and lab-scale Proteus membrane modules were further evaluated using coal-derived syngas streams at the National Carbon Capture Center (NCCC). The results indicate that all module components, including the Proteus membrane, were stable under the field conditions (feed pressures: 150-175 psig and feed temperatures: 120-135C) for over 600 hours. The field performance of both Proteus membrane stamps and Proteus membrane modules is consistent with the results obtained in the lab, suggesting that the presence of sulfur-containing compounds (up to 780 ppm hydrogen sulfide), saturated water vapor, carbon monoxide and heavy hydrocarbons in the syngas feed stream has no adverse effect on the Proteus membrane or module performance. We also performed an economic analysis for a number of membrane process designs developed in this project (using hydrogen-selective membranes, alone or in the combination with CO{sub 2}- selective membranes). The current field performance for Proteus membranes was used in the design analysis. The study showed the current best design has the potential to reduce the increase in Levelized Cost of Electricity (LCOE) caused by 90% CO{sub 2} capture to about 15% if co-sequestration of H{sub 2}S is viable. This value is still higher than the DOE target for increase in LCOE (10%); however, compared to the base-case Selexol process that gives a 30% increase in LCOE at 90% CO2 capture, the membrane-based process appears promising. We believe future improvements in membrane performance have the potential to reach the DOE target.

Merkel, Tim [MTR Inc., Menlo Park, CA (United States)

2011-09-14T23:59:59.000Z

355

Demonstration of Selective Catalytic Reduction Technology to Control Nitrogen Oxice Emissions From High-Sulfur, Coal-Fired Boilers: A DOE Assessment  

NLE Websites -- All DOE Office Websites (Extended Search)

2000/1111 2000/1111 Demonstration of Selective Catalytic Reduction Technology to Control Nitrogen Oxide Emissions From High-Sulfur, Coal- Fired Boilers: A DOE Assessment August 1998 U.S. Department of Energy Office of Fossil Energy Federal Energy Technology Center Morgantown, WV/Pittsburgh, PA 2 Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or respon- sibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference

356

The Advanced Tangentially Fired Combustion Techniques for the Reduction of Nitrogen Oxides (NOx) Emissions From Coal-Fired Boilers Demonstration Project: A DOE Assessment  

NLE Websites -- All DOE Office Websites (Extended Search)

2 2 The Advanced Tangentially Fired Combustion Techniques for the Reduction of Nitrogen Oxides (NO ) Emissions From Coal-Fired Boilers X Demonstration Project: A DOE Assessment March 2000 U.S. Department of Energy National Energy Technology Laboratory P.O. Box 880, 3610 Collins Ferry Road Morgantown, WV 26507-0880 and P.O. Box 10940, 626 Cochrans Mill Road Pittsburgh, PA 15236-0940 2 Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or

357

DEVELOPMENT OF ANALYTICAL METHODS FOR THE QUANTIFICATION OF THE CHEMICAL FORMS OF MERCURY AND OTHER TARGET POLLUTANTS IN COAL-FIRED BOILER FLUE GAS  

Science Conference Proceedings (OSTI)

Since approximately 55% of the electrical power produced in the U. S. is generated by coal-based power utility plants, there is serious concern about the massive amounts of coal combustion products emitted into the atmosphere annually. Furthermore, Title III of the 1990 Clean Air Act Amendments (CAAA) requires the measurement and inventory of a possible 189 hazardous air pollutants (HAPs) from any stationary source producing more than 10 tons per year of any one pollutant or more than 25 tons per year of total pollutants. Although power utilities are not presently included on the list of source categories, the CAAA requires the U. S. Environmental Protection Agency to carry out a study of emissions from electricity generation using fossil fuels. Since many of these HAPs are known to be present in coal derived flue gas, coal-fired electric power utilities may be subject to regulation following these studies if Congress considers it necessary. In a cooperative effort with the U. S. Environmental Protection Agency (EPA), the U. S. Department of Energy (DOE) through its Federal Energy Technology Center (FETC) initiated such a study in 1991. DOE-FETC commissioned five primary contractors to conduct emission studies at eight different coal-fired electric utilities. The eight sites represented a cross section of feed coal type, boiler designs, and particulate and gaseous pollutant control technologies. The major goal of these studies was to determine the sampling and analytical methodologies that could be used efficiently to perform these emission tests while producing representative and reliable emission data. The successful methodology could then be recommended to the EPA for use in compliance testing in the event the regulation of air toxic emissions from coal-fired power plants is implemented. A secondary purpose of the testing was to determine the effectiveness of the control technologies in reducing target hazardous air pollutants. Advanced Technology Systems, Inc. (ATS) as a secondary DOE contractor on this project, assessed the sampling and analytical plans and the emission reports of the five primary contractors to determine how successful the contractors were in satisfying their defined objectives. ATS identified difficulties and inconsistencies in a number of sampling and analytical methodologies in these studies. In particular there was uncertainty as to the validity of the sampling and analytical methods used to differentiate the chemical forms of mercury observed in coal flue gas. Considering the differences in the mercury species with regard to human toxicity, the rate of transport through the ecosystem and the design variations in possible emission control schemes, DOE sought an accurate and reliable means to identify and quantify the various mercury compounds emitted by coal-fired utility boilers. ATS, as a contractor for DOE, completed both bench- and pilot-scale studies on various mercury speciation methods. The final validation of the modified Ontario-Hydro Method, its acceptance by DOE and submission of the method for adoption by ASTM was a direct result of these studies carried out in collaboration with the University of North Dakota's Energy and Environmental Research Center (UNDEERC). This report presents the results from studies carried out at ATS in the development of analytical methods to identify and quantify various chemical species, particularly those of mercury, in coal derived flue gas. Laboratory- and pilot-scale studies, not only on mercury species, but also on other inorganics and organics present in coal combustion flue gas are reported.

Terence J. McManus, Ph.D.

1999-06-30T23:59:59.000Z

358

Hybrid Solvent-Membrane CO2 Capture: A Solvent/Membrane Hybrid Post-combustion CO2 Capture Process for Existing Coal-Fired Power Plants  

SciTech Connect

IMPACCT Project: The University of Kentucky is developing a hybrid approach to capturing CO2 from the exhaust gas of coal-fired power plants. In the first, CO2 is removed as flue gas is passed through an aqueous ammonium-based solvent. In the second, carbon-rich solution from the CO2 absorber is passed through a membrane that is designed to selectively transport the bound carbon, enhancing its concentration on the permeate side. The teams approach would combine the best of both membrane- and solventbased carbon capture technologies. Under the ARPA-E award, the team is enabling the membrane operation to be a drop-in solution.

None

2010-07-01T23:59:59.000Z

359

Evaluation of Solid Sorbents As A Retrofit Technology for CO{sub 2} Capture from Coal-Fired Power Plants  

Science Conference Proceedings (OSTI)

Through a U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) funded cooperative agreement DE-NT0005649, ADA Environmental Solutions (ADA) has begun evaluating the use of solid sorbents for CO{sub 2} capture. The project objective was to address the viability and accelerate development of a solid-based CO{sub 2} capture technology. To meet this objective, initial evaluations of sorbents and the process / equipment were completed. First the sorbents were evaluated using a temperature swing adsorption process at the laboratory scale in a fixed-bed apparatus. A slipstream reactor designed to treat flue gas produced by coal-fired generation of nominally 1 kWe was designed and constructed, which was used to evaluate the most promising materials on a more meaningful scale using actual flue gas. In a concurrent effort, commercial-scale processes and equipment options were also evaluated for their applicability to sorbent-based CO{sub 2} capture. A cost analysis was completed that can be used to direct future technology development efforts. ADA completed an extensive sorbent screening program funded primarily through this project, DOE NETL cooperative agreement DE-NT0005649, with support from the Electric Power Research Institute (EPRI) and other industry participants. Laboratory screening tests were completed on simulated and actual flue gas using simulated flue gas and an automated fixed bed system. The following types and quantities of sorbents were evaluated: 87 supported amines, 31 carbon based materials, 6 zeolites, 7 supported carbonates (evaluated under separate funding), 10 hydrotalcites. Sorbent evaluations were conducted to characterize materials and down-select promising candidates for further testing at the slipstream scale. More than half of the materials evaluated during this program were supported amines. Based on the laboratory screening four supported amine sorbents were selected for evaluation at the 1 kW scale at two different field sites. ADA designed and fabricated a slipstream pilot to allow an evaluation of the kinetic behavior of sorbents and provide some flexibility for the physical characteristics of the materials. The design incorporated a transport reactor for the adsorber (co-current reactor) and a fluidized-bed in the regenerator. This combination achieved the sorbent characterization goals and provided an opportunity to evaluate whether the potential cost savings associated with a relatively simple process design could overcome the sacrifices inherent in a co-current separation process. The system was installed at two field sites during the project, Luminants Martin Lake Steam Electric Station and Xcel Energys Sherburne County Generating Station (Sherco). Although the system could not maintain continuous 90% CO{sub 2} removal with the sorbents evaluated under this program, it was useful to compare the CO{sub 2} removal properties of several different sorbents on actual flue gas. One of the supported amine materials, sorbent R, was evaluated at both Martin Lake and Sherco. The 1 kWe pilot was operated in continuous mode as well as batch mode. In continuous mode, the sorbent performance could not overcome the limitations of the co-current adsorbent design. In batch mode, sorbent R was able to remove up to 90% CO{sub 2} for several cycles. Approximately 50% of the total removal occurred in the first three feet of the adsorption reactor, which was a transport reactor. During continuous testing at Sherco, CO{sub 2} removal decreased to approximately 20% at steady state. The lack of continuous removal was due primarily to the combination of a co-current adsorption system with a fluidized bed for regeneration, a combination which did not provide an adequate driving force to maintain an acceptable working CO{sub 2} capacity. In addition, because sorbent R consisted of a polymeric amine coated on a silica substrate, it was believed that the 50% amine loaded resulted in mass diffusion limitations related to the CO{sub 2} uptake rate. Three additional supported amine materials,

Krutka, Holly; Sjostrom, Sharon

2011-07-31T23:59:59.000Z

360

EVALUATION OF SOLID SORBENTS AS A RETROFIT TECHNOLOGY FOR CO2 CAPTURE FROM COAL-FIRED POWER PLANTS  

Science Conference Proceedings (OSTI)

Through a U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) funded cooperative agreement DE-NT0005649, ADA Environmental Solutions (ADA) has begun evaluating the use of solid sorbents for CO{sub 2} capture. The project objective was to address the viability and accelerate development of a solid-based CO{sub 2} capture technology. To meet this objective, initial evaluations of sorbents and the process/equipment were completed. First the sorbents were evaluated using a temperature swing adsorption process at the laboratory scale in a fixed-bed apparatus. A slipstream reactor designed to treat flue gas produced by coal-fired generation of nominally 1 kWe was designed and constructed, which was used to evaluate the most promising materials on a more meaningful scale using actual flue gas. In a concurrent effort, commercial-scale processes and equipment options were also evaluated for their applicability to sorbent-based CO{sub 2} capture. A cost analysis was completed that can be used to direct future technology development efforts. ADA completed an extensive sorbent screening program funded primarily through this project, DOE NETL cooperative agreement DE-NT0005649, with support from the Electric Power Research Institute (EPRI) and other industry participants. Laboratory screening tests were completed on simulated and actual flue gas using simulated flue gas and an automated fixed bed system. The following types and quantities of sorbents were evaluated: 87 supported amines; 31 carbon based materials; 6 zeolites; 7 supported carbonates (evaluated under separate funding); and 10 hydrotalcites. Sorbent evaluations were conducted to characterize materials and down-select promising candidates for further testing at the slipstream scale. More than half of the materials evaluated during this program were supported amines. Based on the laboratory screening four supported amine sorbents were selected for evaluation at the 1 kW scale at two different field sites. ADA designed and fabricated a slipstream pilot to allow an evaluation of the kinetic behavior of sorbents and provide some flexibility for the physical characteristics of the materials. The design incorporated a transport reactor for the adsorber (co-current reactor) and a fluidized-bed in the regenerator. This combination achieved the sorbent characterization goals and provided an opportunity to evaluate whether the potential cost savings associated with a relatively simple process design could overcome the sacrifices inherent in a co-current separation process. The system was installed at two field sites during the project, Luminant's Martin Lake Steam Electric Station and Xcel Energy's Sherburne County Generating Station (Sherco). Although the system could not maintain continuous 90% CO{sub 2} removal with the sorbents evaluated under this program, it was useful to compare the CO{sub 2} removal properties of several different sorbents on actual flue gas. One of the supported amine materials, sorbent R, was evaluated at both Martin Lake and Sherco. The 1 kWe pilot was operated in continuous mode as well as batch mode. In continuous mode, the sorbent performance could not overcome the limitations of the cocurrent adsorbent design. In batch mode, sorbent R was able to remove up to 90% CO{sub 2} for several cycles. Approximately 50% of the total removal occurred in the first three feet of the adsorption reactor, which was a transport reactor. During continuous testing at Sherco, CO{sub 2} removal decreased to approximately 20% at steady state. The lack of continuous removal was due primarily to the combination of a co-current adsorption system with a fluidized bed for regeneration, a combination which did not provide an adequate driving force to maintain an acceptable working CO{sub 2} capacity. In addition, because sorbent R consisted of a polymeric amine coated on a silica substrate, it was believed that the 50% amine loaded resulted in mass diffusion limitations related to the CO{sub 2} uptake rate. Three additional supported amine materials, so

Holly Krutka; Sharon Sjostrom

2011-07-31T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

Bruce T. Goodwin, 2002 | U.S. DOE Office of Science (SC)  

Office of Science (SC) Website

Bruce T. Goodwin, 2002 The Ernest Orlando Lawrence Award Lawrence Award Home Nomination & Selection Guidelines Award Laureates 2000's 1990's 1980's 1970's 1960's Ceremony The Life...

362

Mercury Measurements Characterizing the Impact of SCR on Mercury: Consol Test Site 3 - Eastern Bituminous Coal-Fired Power Plant Wit h an SCR, ESP, and Wet FGD; Impact of Chloride Addition  

Science Conference Proceedings (OSTI)

CONSOL Energy Inc., Research & Development (CONSOL), with support from the U.S. Department of Energy, National Energy Technology Laboratory (DOE) and the Electric Power Research Institute (EPRI), is evaluating the effects of selective catalytic reduction (SCR) on mercury (Hg) capture in coal-fired plants equipped with an electrostatic precipitator (ESP) - wet flue gas desulfurization (FGD) combination or a spray dyer absorber - fabric filter (SDA-FF) combination. In this program CONSOL is determining mer...

2006-04-26T23:59:59.000Z

363

FIELD TEST PROGRAM FOR LONG-TERM OPERATION OF A COHPAC SYSTEM FOR REMOVING MERCURY FROM COAL-FIRED FLUE GAS  

SciTech Connect

With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by the existing particle control device along with the other solid material, primarily fly ash. During 2001, ADA Environmental Solutions (ADA-ES) conducted a full-scale demonstration of sorbent-based mercury control technology at the Alabama Power E.C. Gaston Station (Wilsonville, AL). This unit burns a low-sulfur bituminous coal and uses a hot-side electrostatic precipitator (ESP) in combination with a Compact Hybrid Particulate Collector (COHPAC{trademark}) baghouse to collect fly ash. The majority of the fly ash is collected in the ESP with the residual being collected in the COHPAC{trademark} baghouse. Activated carbon was injected between the ESP and COHPAC{trademark} units to collect the mercury. Short-term mercury removal levels in excess of 90% were achieved using the COHPAC{trademark} unit. The test also showed that activated carbon was effective in removing both forms of mercury--elemental and oxidized. However, a great deal of additional testing is required to further characterize the capabilities and limitations of this technology relative to use with baghouse systems such as COHPAC{trademark}. It is important to determine performance over an extended period of time to fully assess all operational parameters. The project described in this report focuses on fully demonstrating sorbent injection technology at a coal-fired power generating plant that is equipped with a COHPAC{trademark} system. The overall objective is to evaluate the long-term effects of sorbent injection on mercury capture and COHPAC{trademark} performance. The work is being done on one-half of the gas stream at Alabama Power Company's Plant Gaston Unit 3 (nominally 135 MW). Data from the testing will be used to determine: (1) If sorbent injection into a high air-to-cloth ratio baghouse is a viable, long-term approach for mercury control; and (2) Design criteria and costs for new baghouse/sorbent injection systems that will use a similar, polishing baghouse (TOXECON{trademark}) approach.

Jean Bustard; Charles Lindsey; Paul Brignac; Travis Starns; Sharon Sjostrom; Trent Taylor; Cindy Larson

2004-01-29T23:59:59.000Z

364

FIELD TEST PROGRAM FOR LONG-TERM OPERATION OF A COHPAC SYSTEM FOR REMOVING MERCURY FROM COAL-FIRED FLUE GAS  

SciTech Connect

With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by the existing particle control device along with the other solid material, primarily fly ash. During 2001, ADA Environmental Solutions (ADA-ES) conducted a full-scale demonstration of sorbent-based mercury control technology at the Alabama Power E.C. Gaston Station (Wilsonville, AL). This unit burns a low-sulfur bituminous coal and uses a hot-side electrostatic precipitator (ESP) in combination with a Compact Hybrid Particulate Collector (COHPAC{trademark}) baghouse to collect fly ash. The majority of the fly ash is collected in the ESP with the residual being collected in the COHPAC baghouse. Activated carbon was injected between the ESP and COHPAC units to collect the mercury. Short-term mercury removal levels in excess of 90% were achieved using the COHPAC unit. The test also showed that activated carbon was effective in removing both forms of mercury-elemental and oxidized. However, a great deal of additional testing is required to further characterize the capabilities and limitations of this technology relative to use with baghouse systems such as COHPAC. It is important to determine performance over an extended period of time to fully assess all operational parameters. The project described in this report focuses on fully demonstrating sorbent injection technology at a coal-fired power generating plant that is equipped with a COHPAC system. The overall objective is to evaluate the long-term effects of sorbent injection on mercury capture and COHPAC performance. The work is being done on one-half of the gas stream at Alabama Power Company's Plant Gaston Unit 3 (nominally 135 MW). Data from the testing will be used to determine: (1) If sorbent injection into a high air-to-cloth ratio baghouse is a viable, long-term approach for mercury control; and (2) Design criteria and costs for new baghouse/sorbent injection systems that will use a similar, polishing baghouse (TOXECON{trademark}) approach.

Jean Bustard; Charles Lindsey; Paul Brignac; Travis Starns; Sharon Sjostrom; Trent Taylor; Cindy Larson

2003-10-31T23:59:59.000Z

365

Field Test Program for Long-Term Operation of a COHPAC System for Removing Mercury from Coal-Fired Flue Gas  

Science Conference Proceedings (OSTI)

With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by the existing particle control device along with the other solid material, primarily fly ash. During 2001, ADA Environmental Solutions (ADA-ES) conducted a full-scale demonstration of sorbent-based mercury control technology at the Alabama Power E.C. Gaston Station (Wilsonville, Alabama). This unit burns a low-sulfur bituminous coal and uses a hot-side electrostatic precipitator (ESP) in combination with a Compact Hybrid Particulate Collector (COHPAC{reg_sign}) baghouse to collect fly ash. The majority of the fly ash is collected in the ESP with the residual being collected in the COHPAC{reg_sign} baghouse. Activated carbon was injected between the ESP and COHPAC{reg_sign} units to collect the mercury. Short-term mercury removal levels in excess of 90% were achieved using the COHPAC{reg_sign} unit. The test also showed that activated carbon was effective in removing both forms of mercury-elemental and oxidized. However, a great deal of additional testing is required to further characterize the capabilities and limitations of this technology relative to use with baghouse systems such as COHPAC{reg_sign}. It is important to determine performance over an extended period of time to fully assess all operational parameters. The project described in this report focuses on fully demonstrating sorbent injection technology at a coal-fired power generating plant that is equipped with a COHPAC{reg_sign} system. The overall objective is to evaluate the long-term effects of sorbent injection on mercury capture and COHPAC{reg_sign} performance. The work is being done on one-half of the gas stream at Alabama Power Company's Plant Gaston Unit 3 (nominally 135 MW). Data from the testing will be used to determine: (1) If sorbent injection into a high air-to-cloth ratio baghouse is a viable, long-term approach for mercury control; and (2) Design criteria and costs for new baghouse/sorbent injection systems that will use a similar, polishing baghouse (TOXECON{trademark}) approach.

Jean Bustard; Charles Lindsey; Paul Brignac; Travis Starns; Sharon Sjostrom; Trent Taylor; Cindy Larson

2004-08-06T23:59:59.000Z

366

Field Test Program for Long-Term Operation of a COHPAC System for Removing Mercury from Coal-Fired Flue Gas  

SciTech Connect

With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by the existing particle control device along with the other solid material, primarily fly ash. During 2001, ADA Environmental Solutions (ADA-ES) conducted a full-scale demonstration of sorbent-based mercury control technology at the Alabama Power E.C. Gaston Station (Wilsonville, Alabama). This unit burns a low-sulfur bituminous coal and uses a hot-side electrostatic precipitator (ESP) in combination with a Compact Hybrid Particulate Collector (COHPAC{reg_sign}) baghouse to collect fly ash. The majority of the fly ash is collected in the ESP with the residual being collected in the COHPAC{reg_sign} baghouse. Activated carbon was injected between the ESP and COHPAC{reg_sign} units to collect the mercury. Short-term mercury removal levels in excess of 90% were achieved using the COHPAC{reg_sign} unit. The test also showed that activated carbon was effective in removing both forms of mercury-elemental and oxidized. However, a great deal of additional testing is required to further characterize the capabilities and limitations of this technology relative to use with baghouse systems such as COHPAC{reg_sign}. It is important to determine performance over an extended period of time to fully assess all operational parameters. The project described in this report focuses on fully demonstrating sorbent injection technology at a coal-fired power generating plant that is equipped with a COHPAC{reg_sign} system. The overall objective is to evaluate the long-term effects of sorbent injection on mercury capture and COHPAC{reg_sign} performance. The work is being done on one-half of the gas stream at Alabama Power Company's Plant Gaston Unit 3 (nominally 135 MW). Data from the testing will be used to determine: (1) If sorbent injection into a high air-to-cloth ratio baghouse is a viable, long-term approach for mercury control; and (2) Design criteria and costs for new baghouse/sorbent injection systems that will use a similar, polishing baghouse (TOXECON{trademark}) approach.

Jean Bustard; Charles Lindsey; Paul Brignac; Travis Starns; Sharon Sjostrom; Trent Taylor; Cindy Larson

2004-10-25T23:59:59.000Z

367

FIELD TEST PROGRAM FOR LONG-TERM OPERATION OF A COHPAC SYSTEM FOR REMOVING MERCURY FROM COAL-FIRED FLUE GAS  

SciTech Connect

With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by the existing particle control device along with the other solid material, primarily fly ash. During 2001 ADA Environmental Solutions (ADA-ES) conducted a full-scale demonstration of sorbent-based mercury control technology at the Alabama Power E.C. Gaston Station (Wilsonville, AL). This unit burns a low-sulfur bituminous coal and uses a hot-side electrostatic precipitator (ESP) in combination with a Compact Hybrid Particulate Collector (COHPAC) baghouse to collect fly ash. The majority of the fly ash is collected in the ESP with the residual being collected in the COHPAC baghouse. Activated carbon was injected between the ESP and COHPAC units to collect the mercury. Short-term mercury removal levels in excess of 90% were achieved using the COHPAC unit. The test also showed that activated carbon was effective in removing both forms of mercury: elemental and oxidized. However, a great deal of additional testing is required to further characterize the capabilities and limitations of this technology relative to use with baghouse systems such as COHPAC. It is important to determine performance over an extended period of time to fully assess all operational parameters. The project described in this report focuses on fully demonstrating sorbent injection technology at a coal-fired power generating plant that is equipped with a COHPAC system. The overall objective is to evaluate the long-term effects of sorbent injection on mercury capture and COHPAC performance. The work is being done on one-half of the gas stream at Alabama Power Company's Plant Gaston Unit 3 (nominally 135 MW). Data from the testing will be used to determine: (1) If sorbent injection into a high air-to-cloth ratio baghouse is a viable, long-term approach for mercury control; and (2) Design criteria and costs for new baghouse/sorbent injection systems that will use a similar, polishing baghouse (TOXECON) approach.

Jean Bustard; Charles Lindsey; Paul Brignac; Travis Starns; Sharon Sjostrom; Tom Millar

2003-07-30T23:59:59.000Z

368

Field Test Program for Long-Term Operation of a COHPAC System for Removing Mercury from Coal-Fired Flue Gas  

Science Conference Proceedings (OSTI)

With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by the existing particle control device along with the other solid material, primarily fly ash. During 2001, ADA Environmental Solutions (ADA-ES) conducted a full-scale demonstration of sorbent-based mercury control technology at the Alabama Power E.C. Gaston Station (Wilsonville, Alabama). This unit burns a low-sulfur bituminous coal and uses a hot-side electrostatic precipitator (ESP) in combination with a Compact Hybrid Particulate Collector (COHPAC{reg_sign}) baghouse to collect fly ash. The majority of the fly ash is collected in the ESP with the residual being collected in the COHPAC{reg_sign} baghouse. Activated carbon was injected between the ESP and COHPAC{reg_sign} units to collect the mercury. Short-term mercury removal levels in excess of 90% were achieved using the COHPAC{reg_sign} unit. The test also showed that activated carbon was effective in removing both forms of mercury-elemental and oxidized. However, a great deal of additional testing is required to further characterize the capabilities and limitations of this technology relative to use with baghouse systems such as COHPAC{reg_sign}. It is important to determine performance over an extended period of time to fully assess all operational parameters. The project described in this report focuses on fully demonstrating sorbent injection technology at a coal-fired power generating plant that is equipped with a COHPAC{reg_sign} system. The overall objective is to evaluate the long-term effects of sorbent injection on mercury capture and COHPAC{reg_sign} performance. The work is being done on one-half of the gas stream at Alabama Power Company's Plant Gaston Unit 3 (nominally 135 MW). Data from the testing will be used to determine: (1) If sorbent injection into a high air-to-cloth ratio baghouse is a viable, long-term approach for mercury control; and (2) Design criteria and costs for new baghouse/sorbent injection systems that will use a similar, polishing baghouse (TOXECON{trademark}) approach.

Jean Bustard; Charles Lindsey; Paul Brignac; Travis Starns; Sharon Sjostrom; Cindy Larson

2006-01-27T23:59:59.000Z

369

Field Test Program for Long-Term Operation of a COHPAC System for Removing Mercury from Coal-Fired Flue Gas  

Science Conference Proceedings (OSTI)

With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by the existing particle control device along with the other solid material, primarily fly ash. During 2001, ADA Environmental Solutions (ADA-ES) conducted a full-scale demonstration of sorbent-based mercury control technology at the Alabama Power E.C. Gaston Station (Wilsonville, Alabama). This unit burns a low-sulfur bituminous coal and uses a hot-side electrostatic precipitator (ESP) in combination with a Compact Hybrid Particulate Collector (COHPAC{reg_sign}) baghouse to collect fly ash. The majority of the fly ash is collected in the ESP with the residual being collected in the COHPAC{reg_sign} baghouse. Activated carbon was injected between the ESP and COHPAC{reg_sign} units to collect the mercury. Short-term mercury removal levels in excess of 90% were achieved using the COHPAC{reg_sign} unit. The test also showed that activated carbon was effective in removing both forms of mercury-elemental and oxidized. However, a great deal of additional testing is required to further characterize the capabilities and limitations of this technology relative to use with baghouse systems such as COHPAC{reg_sign}. It is important to determine performance over an extended period of time to fully assess all operational parameters. The project described in this report focuses on fully demonstrating sorbent injection technology at a coal-fired power generating plant that is equipped with a COHPAC{reg_sign} system. The overall objective is to evaluate the long-term effects of sorbent injection on mercury capture and COHPAC{reg_sign} performance. The work is being done on one-half of the gas stream at Alabama Power Company's Plant Gaston Unit 3 (nominally 135 MW). Data from the testing will be used to determine: (1) If sorbent injection into a high air-to-cloth ratio baghouse is a viable, long-term approach for mercury control; and (2) Design criteria and costs for new baghouse/sorbent injection systems that will use a similar, polishing baghouse (TOXECON{trademark}) approach.

Jean Bustard; Charles Lindsey; Paul Brignac; Travis Starns; Sharon Sjostrom; Cindy Larson

2006-04-24T23:59:59.000Z

370

Field Test Program for Long-Term Operation of a COHPAC System for Removing Mercury from Coal-Fired Flue Gas  

Science Conference Proceedings (OSTI)

With the Nation's coal-burning utilities facing the possibility of tighter controls on mercury pollutants, the U.S. Department of Energy is funding projects that could offer power plant operators better ways to reduce these emissions at much lower costs. Sorbent injection technology represents one of the simplest and most mature approaches to controlling mercury emissions from coal-fired boilers. It involves injecting a solid material such as powdered activated carbon into the flue gas. The gas-phase mercury in the flue gas contacts the sorbent and attaches to its surface. The sorbent with the mercury attached is then collected by the existing particle control device along with the other solid material, primarily fly ash. During 2001, ADA Environmental Solutions (ADA-ES) conducted a full-scale demonstration of sorbent-based mercury control technology at the Alabama Power E.C. Gaston Station (Wilsonville, Alabama). This unit burns a low-sulfur bituminous coal and uses a hot-side electrostatic precipitator (ESP) in combination with a Compact Hybrid Particulate Collector (COHPAC{reg_sign}) baghouse to collect fly ash. The majority of the fly ash is collected in the ESP with the residual being collected in the COHPAC{reg_sign} baghouse. Activated carbon was injected between the ESP and COHPAC{reg_sign} units to collect the mercury. Short-term mercury removal levels in excess of 90% were achieved using the COHPAC{reg_sign} unit. The test also showed that activated carbon was effective in removing both forms of mercury-elemental and oxidized. However, a great deal of additional testing is required to further characterize the capabilities and limitations of this technology relative to use with baghouse systems such as COHPAC{reg_sign}. It is important to determine performance over an extended period of time to fully assess all operational parameters. The project described in this report focuses on fully demonstrating sorbent injection technology at a coal-fired power generating plant that is equipped with a COHPAC{reg_sign} system. The overall objective is to evaluate the long-term effects of sorbent injection on mercury capture and COHPAC{reg_sign} performance. The work is being done on one-half of the gas stream at Alabama Power Company's Plant Gaston Unit 3 (nominally 135 MW). Data from the testing will be used to determine: (1) If sorbent injection into a high air-to-cloth ratio baghouse is a viable, long-term approach for mercury control; and (2) Design criteria and costs for new baghouse/sorbent injection systems that will use a similar, polishing baghouse (TOXECON{trademark}) approach.

Jean Bustard; Charles Lindsey; Paul Brignac; Travis Starns; Sharon Sjostrom; Cindy Larson

2005-10-24T23:59:59.000Z

371

Final design of a superconducting MHD magnet for the Coal-Fired Flow Facility at the University of Tennessee Space Institute  

DOE Green Energy (OSTI)

The superconducting magnet system (SCMS) consisting of the superconducting magnet, magnet cryostat, a helium refrigerator/liquefier facility, a helium gas-handling system, apparatus for cryogenic transfer and storage, a magnet power supply, a integrated instrumentation and control system including a computer for magnet operation, data acquisition, system status and diagnosis, and magnet protection is described. The complete system will be tested at Argonne and installed at the Coal-Fired Flow Facility (CFFF) at the University of Tennessee Space Institute (UTSI) in 1981. The coil configuration is the US SCMS type circular saddle. The coil wil be assembled on the magnet tube with spiral banding. The bore tube will be about 6.3 cm thick (in the thickest section) and the banding will be strong enough for coil assembly but too weak to transmit the 30,180 kgf/cm maximum burst force to the bore tube. Fifteen ring girders will be used as the superstructure to contain the force. The decentering force of about 0.2177 x 10/sup 6/ kgf will be taken up by end flanges and bore tubes.

Wang, S T; Turner, L R; Genens, L; Pelczarski, W; Hoffman, J; Gonczy, J; Ludwig, H; Niemann, R C; Mataya, K; Kraft, E

1979-01-01T23:59:59.000Z

372

Oxygen-Fired CO{sub 2} Recycle for Application to Direct CO{sub 2} Capture form Coal-Fired Power Plants  

SciTech Connect

The Southern Research/Southern Company 1 MWth Pilot-Scale Coal-Fired Test Facility was successfully retrofit to fire in either the traditional air-fired mode or with 100% oxygen and recycled flue gas, with a fully integrated feedback and control system, including oxygen and recycled flue gas modulation during startup, transfer, and shutdown, safety and operational interlocks, and data acquisition. A MAXON Staged Oxygen Burner for Oxy-Coal Applications produced a stable flame over a significant range of firing turn-down, staging, and while firing five different U.S. coal types. The MAXON burner design produces lower flame temperatures than for air firing, which will enable (A) Safe operation, (B) Reduction of recycle flow without concern about furnace flame temperatures, and (C) May likely be affective at reducing slagging and fouling in the boiler and super heater at full-scale Power Plants. A CFD model of the Oxy-fired Combustion Research Facility (OCRF) was used to predict the flame geometry and temperatures in the OCRF and make a comparison with the air-fired case. The model predictions were consistent with the experimental data in showing that the MAXON burner fired with oxygen produced lower flame temperatures than the air-fired burner while firing with air.

Thomas Gale

2010-09-26T23:59:59.000Z

373

A study of toxic emissions from a coal-fired power plant utilizing an ESP while demonstrating the ICCT CT-121 FGD Project. Final report  

Science Conference Proceedings (OSTI)

The US Department of Energy is performing comprehensive assessments of toxic emissions from eight selected coal-fired electric utility units. This program responds to the Clean Air Act Amendments of 1990, which require the US Environmental Protection Agency (EPA) to evaluate emissions of hazardous air pollutants (HAPs) from electric utility power plants for Potential health risks. The resulting data will be furnished to EPA utility power plants and health risk determinations. The assessment of emissions involves the collection and analysis of samples from the major input, process, and output streams of each of the eight power plants for selected hazardous Pollutants identified in Title III of the Clean Air Act. Additional goals are to determine the removal efficiencies of pollution control subsystems for these selected pollutants and the Concentrations associated with the particulate fraction of the flue gas stream as a function of particle size. Material balances are being performed for selected pollutants around the entire power plant and several subsystems to identify the fate of hazardous substances in each utility system. Radian Corporation was selected to perform a toxics assessment at a plant demonstrating an Innovative Clean Coal Technology (ICCT) Project. The site selected is Plant Yates Unit No. 1 of Georgia Power Company, which includes a Chiyoda Thoroughbred-121 demonstration project.

Not Available

1994-06-16T23:59:59.000Z

374

Development of a high-performance coal-fired power generating system with pyrolysis gas and char-fired high temperature furnace (HITAF)  

SciTech Connect

A concept for an advanced coal-fired combined-cycle power generating system is currently being developed. The first phase of this three-phase program consists of conducting the necessary research and development to define the system, evaluate the economic and technical feasibility of the concept, and prepare an R D plan to develop the concept further. Foster Wheeler Development Corporation is leading a team ofcompanies involved in this effort. The system proposed to meet these goals is a combined-cycle system where air for a gas turbine is indirectly heated to approximately 1800[degrees]F in furnaces fired with cool-derived fuels and then directly heated in a natural-gas-fired combustor up to about 2400[degrees]F. The system is based on a pyrolyzing process that converts the coal into a low-Btu fuel gas and char. The fuelgas is a relatively clean fuel, and it is fired to heat tube surfaces that are susceptible to corrosion and problems from ash deposition. In particular, the high-temperature air heater tubes, which will need tobe a ceramic material, will be located in a separate furnace or region of a furnace that is exposed to combustion products from the low-Btu fuel gas only. A simplified process flow diagram is shown.

Not Available

1992-11-01T23:59:59.000Z

375

An evaluation of integrated-gasification-combined-cycle and pulverized-coal-fired steam plants: Volume 1, Base case studies: Final report  

SciTech Connect

An evaluation of the performance and costs for a Texaco-based integrated gasification combined cycle (IGCC) power plant as compared to a conventional pulverized coal-fired steam (PCFS) power plant with flue gas desulfurization (FGD) is provided. A general set of groundrules was used within which each plant design was optimized. The study incorporated numerous sensitivity cases along with up-to-date operating and cost data obtained through participation of equipment vendors and process developers. Consequently, the IGCC designs presented in this study use the most recent data available from Texaco's ongoing international coal gasification development program and General Electric's continuing gas turbine development efforts. The Texaco-based IGCC has advantages over the conventional PCFS technology with regard to environmental emissions and natural resource requirements. SO/sub 2/, NOx, and particulate emissions are lower. Land area and water requirements are less for IGCC concepts. Coal consumption is less due to the higher plant thermal efficiency attainable in the IGCC plant. The IGCC plant also has the capability to be designed in several different configurations, with and without the use of natural gas or oil as a backup fuel. This capability may prove to be particularly advantageous in certain utility planning and operation scenarios. 107 figs., 114 tabs.

Pietruszkiewicz, J.; Milkavich, R.J.; Booras, G.S.; Thomas, G.O.; Doss, H.

1988-09-01T23:59:59.000Z

376

An evaluaton of integrated-gasification-combined-cycle and pulverized-coal-fired steam plants: Volume 2, Sensitivity studies and appendixes: Final report  

SciTech Connect

The Electric Power Research Institute contracted with Bechtel Group, Inc., to provide an evaluation of the performance and costs for a Texaco-based integrated gasification combined cycle (IGCC) power plant as compared to a conventional pulverized coal-fired steam (PCFS) power plant with flue gas desulfurization (FGD). A general set of groundrules was used within which each plant design was optimized. The study incorporated numerous sensitivity cases along with up-to-date operating and cost data obtained through participation of equipment vendors and process developers. Consequently, the IGCC designs presented in this study use the most recent data available from Texaco's ongoing international coal gasification development program and General Electric's continuing gas turbine development efforts. The study confirms that the Texaco-based IGCC has advantages over the conventional PCFS technology with regard to environmental emissions and natural resource requirements. SO/sub 2/, NOx, and particulate emissions are lower. Land area and water requirements are less for IGCC concepts. In addition, coal consumption is less due to the higher plant thermal efficiency attainable in the IGCC plant. The IGCC plant also has the capability to be designed in several different configurations, with and without the use of natural gas or oil as a backup fuel. This capability may prove to be particularly advantageous in certain utility planning and operation scenarios.

Pietruszkiewicz, J.; Milkavich, R.J.; Booras, G.S.; Thomas, G.O.; Doss, H.

1988-09-01T23:59:59.000Z

377

A study of toxic emissions from a coal-fired power plant utilizing an ESP/Wet FGD system. Volume 1, Sampling, results, and special topics: Final report  

Science Conference Proceedings (OSTI)

This was one of a group of assessments of toxic emissions from coal-fired power plants, conducted for DOE-PETC in 1993 as mandated by the 1990 Clean Air Act. It is organized into 2 volumes; Volume 1 describes the sampling effort, presents the concentration data on toxic chemicals in several power plant streams, and reports the results of evaluations and calculations. The study involved solid, liquid, and gaseous samples from input, output, and process streams at Coal Creek Station Unit No. 1, Underwood, North Dakota (1100 MW mine-mouth plant burning lignite from the Falkirk mine located adjacent to the plant). This plant had an electrostatic precipitator and a wet scrubber flue gas desulfurization unit. Measurements were conducted on June 21--24, 26, and 27, 1993; chemicals measured were 6 major and 16 trace elements (including Hg, Cr, Cd, Pb, Se, As, Be, Ni), acids and corresponding anions (HCl, HF, chloride, fluoride, phosphate, sulfate), ammonia and cyanide, elemental C, radionuclides, VOCs, semivolatiles (incl. PAH, polychlorinated dioxins, furans), and aldehydes. Volume 2: Appendices includes process data log sheets, field sampling data sheets, uncertainty calculations, and quality assurance results.

Not Available

1994-07-01T23:59:59.000Z

378

Dry SO/sub 2/ particulate removal for coal-fired boilers. Volume 2. 22-MW demonstration using nahcolite, trona, and soda ash. Final report  

Science Conference Proceedings (OSTI)

The second phase of a full scale demonstration of the integration of the dry injection of sodium sorbents coupled with a fabric filter baghouse was conducted at Public Service Company of Colorado's Cameo Unit 1, a 22 MW coal-fired utility boiler equipped with an eight compartment baghouse. An initial test series conducted in 1980 had demonstrated the capability of 70% SO/sub 2/ removal with nahcolite injection without significant impact on the baghouse operation. The objectives of the second test series were to expand the evaluation of nahcolite to operation at reduced baghouse temperatures, high temperature injection and varied coal applications, and the use of several alternative and potentially more available sorbent materials. SO/sub 2/ removal was shown to be primarily a function of the type and rate of sorbent injection. The performance of nahcolite was consistent with the previous tests achieving approximately 80% SO/sub 2/ removal with the injection of a stoichiometric amount into the flue gases. Comparable injection quantities of the three trona materials evaluated resulted in 55% SO/sub 2/ removal. Soda ash was ineffective in removing SO/sub 2/ at all injection rates. No significant differences in the SO/sub 2/ removal characteristics of nahcolite were observed while firing coal from several sources. Sorbent injection had no appreciable impact on the baghouse pressure drop characteristics or bag cleanability. Baghouse collection efficiency remained at 99.9+% levels. 3 references, 19 figures, 8 tables.

Muzio, L.J.; Sonnichsen, T.W.

1984-06-01T23:59:59.000Z

379

Engineering development of advanced coal-fired low-emission boiler systems: Technical progress report No. 16, July-September 1996  

SciTech Connect

The overall objective of the Project is the expedited commercialization of advanced coal-fired low-emission boiler systems. The Project is under budget and generally on schedule. The current status is shown in the Milestone Schedule Status Report included as Appendix A. Under Task 7--Component development and optimization, the CeraMem filter testing was completed. Due to an unacceptably high flue gas draft loss, which will not be resolved in the POCTF timeframe, a decision was made to change the design of the flue gas cleaning system from Hot SNO{sub x}{sup {trademark}} to an advanced dry scrubber called New Integrated Desulfurization (NID). However, it is recognized that the CeraMem filter still has the potential to be viable in pulverized coal systems. In Task 8-- Preliminary POCTF design, integrating and optimizing the performance and design of the boiler, turbine/generator and heat exchangers of the Kalina cycle as well as the balance of plant design were completed. Licensing activities continued. A NID system was substituted for the SNO{sub x} Hot Process.

Barcikowski, G.F.; Borio, R.W.; Bozzuto, C.R.; Burr, D.H.; Cellilli, L.; Fox, J.D.; Gibbons, T.B.; Hargrove, M.J.; Jukkola, G.D.; King, A.M.

1996-11-27T23:59:59.000Z

380

Development of a high-performance coal-fired power generating system with pyrolysis gas and char-fired high-temperature furnace (HITAF): Volume 4. Final report  

Science Conference Proceedings (OSTI)

An outgrowth of our studies of the FWDC coal-fired high performance power systems (HIPPS) concept was the development of a concept for the repowering of existing boilers. The initial analysis of this concept indicates that it will be both technically and economically viable. A unique feature of our greenfields HIPPS concept is that it integrates the operation of a pressurized pyrolyzer and a pulverized fuel-fired boiler/air heater. Once this type of operation is achieved, there are a few different applications of this core technology. Two greenfields plant options are the base case plant and a plant where ceramic air heaters are used to extend the limit of air heating in the HITAF. The greenfields designs can be used for repowering in the conventional sense which involves replacing almost everything in the plant except the steam turbine and accessories. Another option is to keep the existing boiler and add a pyrolyzer and gas turbine to the plant. The study was done on an Eastern utility plant. The owner is currently considering replacing two units with atmospheric fluidized bed boilers, but is interested in a comparison with HIPPS technology. After repowering, the emissions levels need to be 0.25 lb SO{sub x}/MMBtu and 0.15 lb NO{sub x}/MMBtu.

NONE

1996-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Development and testing of a commercial scale coal-fired combustion system, Phase 3. Quarterly technical progress report No. 8, July 1, 1992--September 30, 1992  

SciTech Connect

This report summarizes the results of work performed in the development and proof-of-concept (POC) testing of a coal-fired space heating system for the commercial market sector. The objective of this program is to design, build and test a coal based heating system for this sector and determine the economic viability and market potential for the system. Coal water slurry (CWS) fuel has been chosen as the fuel form for this development effort. CWS eliminates the need to use dry pulverized coal with its attendant handling, metering and dusting problems as well as its explosive potential. Equally important in selecting a fuel form is the impact on emission levels and pollution control equipment requirements. CWS is amenable to coal washing since coal cleaning technologies are generally water-based processes requiring the fine grinding of the coal. In the first stage. an overall system heat balance was prepared, system components were designed and manufactured or purchased, the system was fully assembled and preliminary testing performed to validate component performance and identify key operating variables. In the second stage the system was operated for prolonged periods to simulate a commercial application, and combustion and thermal efficiencies; tendencies to slag, foul, erode and corrode; and gaseous and particulate emissions were evaluated. Also during the second stage, an assessment of the commercial viability of the system was made. This assessment included an evaluation of the economics and market potential, including the sensitivity to fluctuations in fuel prices.

Litka, A.; Breault, R.

1992-10-23T23:59:59.000Z

382

Proof-of-concept tests of the magnetohydrodynamic steam-bottoming system at the DOE Coal-Fired Flow Facility. Final report  

DOE Green Energy (OSTI)

The development of coal-fired magnetohydrodynamic (MHD) power can be viewed as consisting of two parts; the topping cycle and the bottoming cycle. The topping cycle consists of the coal combustor, MHD generator and associated components. The bottoming cycle consists of the heat recovery, steam generation, seed recovery/regeneration, emissions control (gas and particulate), ash handling and deposition, and materials evaluation. The report concentrates on the bottoming cycle, for which much of the technology was developed at the University of Tennessee Space Institute (UTSI). Because of the complexity of the required technology, a number of issues required investigation. Of specific concern regarding the bottoming cycle, was the design of the steam cycle components and emissions control. First, the high combustion temperatures and the use of large quantities of potassium in the MHD combustor results in a difference in the composition of the gases entering the bottoming cycle compared to conventional systems. Secondly, a major goal of the UTSI effort was to use a variety of coals in the MHD system, especially the large reserves of high-sulfur coals available in the United States.

Attig, R.C. [ed.

1996-10-09T23:59:59.000Z

383

Development and testing of industrial scale, coal-fired combustion system, Phase 3. Seventeenth quarterly technical progress report, January 1, 1996--March 31, 1996  

SciTech Connect

In the first quarter of calendar year 1996, 9 days of combust-boiler tests were performed. Between these tests, modifications and improvements that were indicated by these tests were implemented. In January and early February, the modifications and installations indicated by the 6 days of testing in December 1995 were implemented. This was followed by 6 additional consecutive test days in mid- February. This was in turn followed by additional modifications, followed by a series of 3 one day, coal fired tests at end of March. These latter tests were the first ones in which slagging conditions were achieved in the combustor. The maximum thermal input was 13 MMBtu/hr, which equals two-thirds of the rated boiler heat input. The measured thermal, combustion, and slagging performance achieved in the combustor was superior to that achieved in the final series of tests conducted in Williamsport in 1993. The combustor-boiler facility is now ready for implementation of the task 5 site demonstration.

Zauderer, B.

1996-04-07T23:59:59.000Z

384

Cermet composite thermal spray coatings for erosion and corrosion protection in combustion environments of advanced coal-fired boilers. Semiannual technical report, January 14, 1997--August 14, 1997  

SciTech Connect

Research is presently being conducted to determine the optimum ceramic/metal combination in thermally sprayed metal matrix composite coatings for erosion and corrosion resistance in new coal-fired boilers. The research will be accomplished by producing model cermet composites using powder metallurgy and electrodeposition methods in which the effect of ceramic/metal combination for the erosion and corrosion resistance will be determined. These results will provide the basis for determining the optimum hard phase constituent size and volume percent in thermal spray coatings. Thermal spray coatings will be applied by our industrial sponsor and tested in our erosion and corrosion laboratories. Bulk powder processed Ni-Al{sub 2}O{sub 3} composites were produced at Idaho National Engineering Laboratory. The composite samples contained 0, 21, 27, 37, and 45 volume percent Al{sub 2}O{sub 3} with an average particle size of 12 um. Also, to deposit model Ni-Al{sub 2}O{sub 3} coatings, an electrodeposition technique was developed and coatings with various volume fractions (0-35%) of Al{sub 2}O{sub 3} were produced. The powder and electrodeposition processing of Ni-Al{sub 2}O{sub 3} Composites provide the ability to produce two phase microstructure without changing the microstructure of the matrix material. Therefore, the effect of hard second phase particles size and volume fraction on erosion resistance could be analyzed.

Schorr, B.S.; Levin, B.F.; DuPont, J.N.; Marder, A.R.

1997-08-31T23:59:59.000Z

385

The Carnol System for methanol production and CO{sub 2} mitigation from coal fired power plants and the transportation sector  

DOE Green Energy (OSTI)

The Carnol System consists of methanol production by C0{sub 2} recovered from coal fired power plants and natural gas and the use of the methanol as an alternative automotive fuel. The Carnol process produces hydrogen by the thermal decomposition of natural gas and reacting the hydrogen with C0{sub 2} recovered from the power plant. The carbon produced can be stored or used as a materials commodity. A design and economic evaluation of the process is presented and compared to gasoline as an automotive fuel. An evaluation of the C0{sub 2} emission reduction of the process and system is made and compared to other conventional methanol production processes is including the use of biomass feedstock and methanol fuel cell vehicles. The C0{sub 2} for the entire Carnol System using methanol in automotive IC engines can be reduced by 56% compared to conventional system of coal plants and gasoline engines and by as much as 77% C0{sub 2} emission reduction when methanol is used in fuel cells in automotive engines. The Carnol System is shown to be an environmentally attractive and economically viable system connecting the power generation sector with the transportation sector which should warrant further development.

Steinberg, M.

1996-02-01T23:59:59.000Z

386

The Carnol System for methanol production and CO{sub 2} mitigation from coal fired power plants and the transportation sector  

DOE Green Energy (OSTI)

The Carnol System consists of methanol production by CO{sub 2} recovered from coal fired power plants and natural gas and the use of the methanol as an alternative automotive fuel. The Carnol Process produces hydrogen by the thermal decomposition of natural gas and reacting the hydrogen with CO{sub 2} recovered from the power plant. The carbon produced can be stored or used as a materials commodity. A design and economic evaluation of the Carnol System is presented and compared to gasoline as an automotive fuel. An evaluation of the CO{sub 2} emission reduction of the process and system is made and compared to other conventional methanol production processes is including the use of biomass feedstock and methanol fuel cell vehicles. The CO{sub 2} for the entire Carnol System using methanol in automotive IC engines can be reduced by 56% compared to conventional system of coal plants and gasoline engines and by as much as 77% CO{sub 2} emission reduction when methanol is used in fuel cells in automotive engines. The Carnol System is shown to be an environmentally attractive and economically viable system connecting the power generation sector with the transportation sector which should warrant further development.

Steinberg, M.

1996-11-01T23:59:59.000Z

387

ENGINEERING FEASIBILITY AND ECONOMICS OF CO2 SEQUESTRATION/USE ON AN EXISTING COAL-FIRED POWER PLANT: A LITERATURE REVIEW  

SciTech Connect

The overall objective of this study is to evaluate the technical feasibility and the economics of alternate CO{sub 2} capture and sequestration/use technologies for retrofitting an existing pulverized coal-fired power plant. To accomplish this objective three alternative CO{sub 2} capture and sequestration systems will be evaluated to identify their impact on an existing boiler, associated boiler auxiliary components, overall plant operation and performance and power plant cost, including the cost of electricity. The three retrofit technologies that will be evaluated are as follows: (1) Coal combustion in air, followed by CO{sub 2} separation from flue gas with Kerr-McGee/ABB Lummus Global's commercial MEA-based absorption/stripping process. (2) Coal combustion in an O{sub 2}/CO{sub 2} environment with CO{sub 2} recycle. (3) Coal combustion in air with oxygen removal and CO{sub 2} captured by tertiary amines In support of this objective and execution of the evaluation of the three retrofit technologies a literature survey was conducted. It is presented in an ''annotated'' form, consistent with the following five sections: (1) Coal Combustion in O{sub 2}/CO{sub 2} Media; (2) Oxygen Separation Technologies; (3) Post Combustion CO{sub 2} Separation Technologies; (4) Potential Utilization of CO{sub 2}; and (5) CO{sub 2} Sequestration. The objective of the literature search was to determine if the three retrofit technologies proposed for this project continue to be sound choices. Additionally, a review of the literature would afford the opportunity to determine if other researchers have made significant progress in developing similar process technologies and, in that context, to revisit the current state-of-the-art. Results from this literature survey are summarized in the report.

Carl R. Bozzuto; Nsakala ya Nsakala

2000-01-31T23:59:59.000Z

388

Characterization of open-cycle coal-fired MHD generators. Quarterly technical summary report No. 6, October 1--December 31, 1977. [PACKAGE code  

DOE Green Energy (OSTI)

Research has included theoretical modeling of important plasma chemical effects such as: conductivity reductions due to condensed slag/electron interactions; conductivity and generator efficiency reductions due to the formation of slag-related negative ion species; and the loss of alkali seed due to chemical combination with condensed slag. A summary of the major conclusions in each of these areas is presented. A major output of the modeling effort has been the development of an MHD plasma chemistry core flow model. This model has been formulated into a computer program designated the PACKAGE code (Plasma Analysis, Chemical Kinetics, And Generator Efficiency). The PACKAGE code is designed to calculate the effect of coal rank, ash percentage, ash composition, air preheat temperatures, equivalence ratio, and various generator channel parameters on the overall efficiency of open-cycle, coal-fired MHD generators. A complete description of the PACKAGE code and a preliminary version of the PACKAGE user's manual are included. A laboratory measurements program involving direct, mass spectrometric sampling of the positive and negative ions formed in a one atmosphere coal combustion plasma was also completed during the contract's initial phase. The relative ion concentrations formed in a plasma due to the methane augmented combustion of pulverized Montana Rosebud coal with potassium carbonate seed and preheated air are summarized. Positive ions measured include K/sup +/, KO/sup +/, Na/sup +/, Rb/sup +/, Cs/sup +/, and CsO/sup +/, while negative ions identified include PO/sub 3//sup -/, PO/sub 2//sup -/, BO/sub 2//sup -/, OH/sup -/, SH/sup -/, and probably HCrO/sub 3/, HMoO/sub 4//sup -/, and HWO/sub 3//sup -/. Comparison of the measurements with PACKAGE code predictions are presented. Preliminary design considerations for a mass spectrometric sampling probe capable of characterizing coal combustion plasmas from full scale combustors and flow trains are presented and discussed.

Kolb, C.E.; Yousefian, V.; Wormhoudt, J.; Haimes, R.; Martinez-Sanchez, M.; Kerrebrock, J.L.

1978-01-30T23:59:59.000Z

389

Comparison of techniques for mixed-space collaborative navigation Aaron Stafford Bruce H. Thomas Wayne Piekarski  

E-Print Network (OSTI)

Comparison of techniques for mixed-space collaborative navigation Aaron Stafford Bruce H. Thomas Lakes Blvd, Mawson Lakes, South Australia, 5095 Email: {aaron.stafford reality (AR) system (Stafford et al. 2006). The 3D reconstruction tabletop display (HOG table), as seen

Thomas, Bruce

390

Efficiency of Techniques for Mixed-Space Collaborative Navigation Aaron Stafford Bruce H. Thomas Wayne Piekarski  

E-Print Network (OSTI)

Efficiency of Techniques for Mixed-Space Collaborative Navigation Aaron Stafford Bruce H. Thomas consuming to remotely navigate a person using only voice commands. e-mail: aaron.stafford@unisa.edu.au e desktop collaborative virtual environments. Virtual Reality, 7(3-4):164­174, Jun 2004. [4] A. Stafford, W

Thomas, Bruce

391

Competitiveness of Biomass-Fueled Electrical Power Plants Bruce A. McCarl  

E-Print Network (OSTI)

Competitiveness of Biomass-Fueled Electrical Power Plants Bruce A. McCarl Professor Department with suggested rollbacks in greenhouse gas emissions is by employing power plant fueled with biomass. We examine the competitiveness of biomass-based fuel for electrical power as opposed to coal using a mathematical programming

McCarl, Bruce A.

392

KINETICS OF GAS-GRAIN REACTIONS IN THE SOLAR NEBULA BRUCE FEGLEY, JR.  

E-Print Network (OSTI)

KINETICS OF GAS-GRAIN REACTIONS IN THE SOLAR NEBULA BRUCE FEGLEY, JR. Planetary Chemistry gas phase, gas-grain, and solid phase reactions as a function of pressure and temperature in the solar the local en- vironment cooled significantly or before the gaseous solar nebula was dispersed

Fegley Jr., Bruce

393

The APO 3.5-meter remote observing program--2002 and beyond Bruce Gillespie*  

E-Print Network (OSTI)

The APO 3.5-meter remote observing program--2002 and beyond Bruce Gillespie* Site Operations Manager, Apache Point Observatory ABSTRACT The Apache Point Observatory 3.5-meter telescope is a working operational models. Keywords: Astrophysical Research Consortium, Apache Point Observatory, 3.5-meter telescope

Castillo, Steven P.

394

PARTICULATE CHARACTERIZATION AND ULTRA LOW-NOx BURNER FOR THE CONTROL OF NO{sub x} AND PM{sub 2.5} FOR COAL FIRED BOILERS  

SciTech Connect

In response to the serious challenge facing coal-fired electric utilities with regards to curbing their NO{sub x} and fine particulate emissions, Babcock and Wilcox and McDermott Technology, Inc. conducted a project entitled, ''Particulate Characterization and Ultra Low-NO{sub x} Burner for the Control of NO{sub x} and PM{sub 2.5} for Coal Fired Boilers.'' The project included pilot-scale demonstration and characterization of technologies for removal of NO{sub x} and primary PM{sub 2.5} emissions. Burner development and PM{sub 2.5} characterization efforts were based on utilizing innovative concepts in combination with sound scientific and fundamental engineering principles and a state-of-the-art test facility. Approximately 1540 metric tonnes (1700 tons) of high-volatile Ohio bituminous coal were fired. Particulate sampling for PM{sub 2.5} emissions characterization was conducted in conjunction with burner testing. Based on modeling recommendations, a prototype ultra low-NO{sub x} burner was fabricated and tested at 100 million Btu/hr in the Babcock and Wilcox Clean Environment Development Facility. Firing the unstaged burner with a high-volatile bituminous Pittsburgh 8 coal at 100 million Btu/hr and 17% excess air achieved a NO{sub x} goal of 0.20 lb NO{sub 2}/million Btu with a fly ash loss on ignition (LOI) of 3.19% and burner pressure drop of 4.7 in H{sub 2}O for staged combustion. With the burner stoichiometry set at 0.88 and the overall combustion stoichiometry at 1.17, average NO{sub x} and LOI values were 0.14 lb NO{sub 2}/million Btu and 4.64% respectively. The burner was also tested with a high-volatile Mahoning 7 coal. Based on the results of this work, commercial demonstration is being pursued. Size classified fly ash samples representative of commercial low-NO{sub x} and ultra low-NO{sub x} combustion of Pittsburgh 8 coal were collected at the inlet and outlet of an ESP. The mass of size classified fly ash at the ESP outlet was sufficient to evaluate the particle size distribution, but was of insufficient size to permit reliable chemical analysis. The size classified fly ash from the inlet of the ESP was used for detailed chemical analyses. Chemical analyses of the fly ash samples from the ESP outlet using a high volume sampler were performed for comparison to the size classified results at the inlet. For all test conditions the particulate removal efficiency of the ESP exceeded 99.3% and emissions were less than the NSPS limits of {approx}48 mg/dscm. With constant combustion conditions, the removal efficiency of the ESP increased as the ESP voltage and Specific Collection Area (SCA) increased. The associated decrease in particle emissions occurred in size fractions both larger and smaller than 2.5 microns. For constant ESP voltage and SCA, the removal efficiency for the ultra low-NO{sub x} combustion ash (99.4-99.6%) was only slightly less than for the low-NO{sub x} combustion ash (99.7%). The decrease in removal efficiency was accompanied by a decrease in ESP current. The emission of PM{sub 2.5} from the ESP did not change significantly as a result of the change in combustion conditions. Most of the increase in emissions was in the size fraction greater than 2.5 microns, indicating particle re-entrainment. These results may be specific to the coal tested in this program. In general, the concentration of inorganic elements and trace species in the fly ash at the ESP inlet was dependent on the particle size fraction. The smallest particles tended to have higher concentrations of inorganic elements/trace species than larger particles. The concentration of most elements by particle size range was independent of combustion condition and the concentration of soluble ions in the fly ash showed little change with combustion condition when evaluated on a carbon free basis.

Ralph Bailey; Hamid Sarv; Jim Warchol; Debi Yurchison

2001-09-30T23:59:59.000Z

395

Field Test Program for Long-Term Operation of a COHPAC System for Removing Mercury from Coal-Fired Flue Gas  

Science Conference Proceedings (OSTI)

This document provides a summary of the full-scale demonstration efforts involved in the project ''Field Test Program for Long-Term Operation of a COHPAC{reg_sign} System for Removing Mercury from Coal-Fired Flue Gas''. The project took place at Alabama Power's Plant Gaston Unit 3 and involved the injection of sorbent between an existing particulate collector (hot-side electrostatic precipitators) and a COHPAC{reg_sign} fabric filter (baghouse) downstream. Although the COHPAC{reg_sign} baghouse was designed originally for polishing the flue gas, when activated carbon injection was added, the test was actually evaluating the EPRI TOXECON{reg_sign} configuration. The results from the baseline tests with no carbon injection showed that the cleaning frequency in the COHPAC{reg_sign} unit was much higher than expected, and was above the target maximum cleaning frequency of 1.5 pulses/bag/hour (p/b/h), which was used during the Phase I test in 2001. There were times when the baghouse was cleaning continuously at 4.4 p/b/h. In the 2001 tests, there was virtually no mercury removal at baseline conditions. In this second round of tests, mercury removal varied between 0 and 90%, and was dependent on inlet mass loading. There was a much higher amount of ash exiting the electrostatic precipitators (ESP), creating an inlet loading greater than the design conditions for the COHPAC{reg_sign} baghouse. Tests were performed to try to determine the cause of the high ash loading. The LOI of the ash in the 2001 baseline tests was 11%, while the second baseline tests showed an LOI of 17.4%. The LOI is an indication of the carbon content in the ash, which can affect the native mercury uptake, and can also adversely affect the performance of ESPs, allowing more ash particles to escape the unit. To overcome this, an injection scheme was implemented that balanced the need to decrease carbon injection during times when inlet loading to the baghouse was high and increase carbon injection when inlet loading and mercury removal were low. The resulting mercury removal varied between 50 and 98%, with an overall average of 85.6%, showing that the process was successful at removing high percentages of vapor-phase mercury even with a widely varying mass loading. In an effort to improve baghouse performance, high-permeability bags were tested. The new bags made a significant difference in the cleaning frequency of the baghouse. Before changing the bags, the baghouse was often in a continuous clean of 4.4 p/b/h, but with the new bags the cleaning frequency was very low, at less than 1 p/b/h. Alternative sorbent tests were also performed using these high-permeability bags. The results of these tests showed that most standard, high-quality activated carbon performed similarly at this site; low-cost sorbent and ash-based sorbents were not very effective at removing mercury; and chemically enhanced sorbents did not appear to offer any benefits over standard activated carbons at this site.

C. Jean Bustard; Charles Lindsey; Paul Brignac

2006-05-01T23:59:59.000Z

396

Pumping test and fluid sampling report, Mansfield No. 1 well, Palo Duro Basin: Report of the Geologic Project Manager, Permian Basin  

SciTech Connect

This report describes pumping test and fluid sampling activities performed at the Mansfield No. 1 well in Oldham County about 10 miles north of Vega, Texas. The well site was selected by TBEG and is located along the northern margin of the Palo Duro Basin in an area of active dissolution with the Permian salt sections. The objectives of the pumping test and fluid sampling program were to collect data to determine the hydrologic characteristics (formation pressure and permeability) of deep water bearing formations, and to obtain formation fluid samples for analyses (gas and fluid chemistry) in order to evaluate fluid migration and age relationships in the Permian Basin. 4 refs., 8 figs., 2 tabs.

Not Available

1983-07-01T23:59:59.000Z

397

Application of a Heat Integrated Post-combustion CO2 Capture System with Hitachi Advanced Solvent into Existing Coal-Fired Power Plant Award Number: DE-FE0007395 DOE Project Manager: José D. Figueroa  

NLE Websites -- All DOE Office Websites (Extended Search)

a Heat Integrated Post- a Heat Integrated Post- combustion CO 2 Capture System with Hitachi Advanced Solvent into Existing Coal-Fired Power Plant University of Kentucky Research Foundation Partnered with U.S. Department of Energy NETL Louisville Gas & Electric and Kentucky Utilities Electric Power Research Institute (with WorleyParsons) Hitachi Power Systems America Smith Management Group July 9, 2013 Goals and Objectives * Objectives 1) To demonstrate a heat-integrated post-combustion CO 2 capture system with an advanced solvent; 2) To collect information/data on material corrosion and identify appropriate materials of construction for a 550 MWe commercial-scale carbon capture plant.  To gather data on solvent degradation kinetics, water management, system dynamic control as well as other information during the long-term

398

Development of a high-performance coal-fired power generating system with pyrolysis gas and char-fired high temperature furnace (HITAF). Progress report No. 12, September--December 1994  

SciTech Connect

A concept for an advanced coal-fired combined-cycle power generating system is currently being developed. The first phase of this three-phase program consists of conducting the necessary research and development to define the system, evaluating the economic and technical feasibility of the concept, and preparing an R&D plan to develop the concept further. There are two basic arrangements of our HIPPS cycle. Both are coal-fired combined cycles. One arrangement is the 35% natural gas HIPPS. Coal is converted to fuel gas and char in a pyrolysis process, and these fuels are fired in separate parts of a high temperature advanced furnace (HITAF). The char-fired furnace produces flue gas that is used to heat gas turbine air up to 1400 F. Alloy tubes are used for these tube banks. After leaving the alloy tube banks, the gas turbine air goes through a ceramic air heater where it is heated from 1400 F to 1800 F. The flue gas that goes through the ceramic air heater comes from the combustion of the fuel gas that is produced in the pyrolysis process. This fuel gas is cleaned to remove particulates and alkalies that would corrode and plug a ceramic air heater. The air leaving the ceramic air heater needs to be heated further to achieve the efficiency goal of 47%, and this is done by firing natural gas in the gas turbine combustor. An alternative arrangement of the HIPPS cycle is called the All Coal HIPPS. With this arrangement, the char is used to heat the gas turbine air to 1400 F as before, but instead of then going to a ceramic air heater, the air goes directly to the gas turbine combustor. The fuel gas generated in the pyrolyzer is used as fuel in the gas turbine combustor. In both cycle arrangements, heat is transferred to the steam cycle in the HITAF and a heat recovery steam generator (HRSG).

1995-06-01T23:59:59.000Z

399

Bruce Odekirk  

Science Conference Proceedings (OSTI)

Sponsored by: TMS: Energy Conversion and Storage Committee, TMS: Magnetic ... PPG has been a supplier of power transistors and diodes to many market ... I will review our latest developments in thermal analysis approaches for this...

400

Bruce Nordman  

NLE Websites -- All DOE Office Websites (Extended Search)

Symposium The electric power system of the future - Integrating supergrids and microgrids. Bologna, Italy: LBNL, 2011. Download: PDF (2.66 MB) 2009 Koomey, Jonathan G.,...

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Bruce Ravel  

Science Conference Proceedings (OSTI)

... conjunction with novel theory and analysis methods to develop, understand, and optimize materials for microelectronics, catalysis, energy science ...

2013-05-02T23:59:59.000Z

402

Bruce Nordman  

NLE Websites -- All DOE Office Websites (Extended Search)

He also works on low-power mode energy consumption, on user interface issues for electronics power control and lighting, and on miscellaneous energy use, and on developing...

403

Development of a high-performance coal-fired power generating system with pyrolysis gas and char-fired high temperature furnace (HITAF). Quarterly progress report No. 3, July--September 1992  

SciTech Connect

A concept for an advanced coal-fired combined-cycle power generating system is currently being developed. The first phase of this three-phase program consists of conducting the necessary research and development to define the system, evaluate the economic and technical feasibility of the concept, and prepare an R & D plan to develop the concept further. Foster Wheeler Development Corporation is leading a team ofcompanies involved in this effort. The system proposed to meet these goals is a combined-cycle system where air for a gas turbine is indirectly heated to approximately 1800{degrees}F in furnaces fired with cool-derived fuels and then directly heated in a natural-gas-fired combustor up to about 2400{degrees}F. The system is based on a pyrolyzing process that converts the coal into a low-Btu fuel gas and char. The fuelgas is a relatively clean fuel, and it is fired to heat tube surfaces that are susceptible to corrosion and problems from ash deposition. In particular, the high-temperature air heater tubes, which will need tobe a ceramic material, will be located in a separate furnace or region of a furnace that is exposed to combustion products from the low-Btu fuel gas only. A simplified process flow diagram is shown.

Not Available

1992-11-01T23:59:59.000Z

404

Innovative clean coal technology: 500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NOx) emissions from coal-fired boilers. Final report, Phases 1 - 3B  

SciTech Connect

This report presents the results of a U.S. Department of Energy (DOE) Innovative Clean Coal Technology (ICCT) project demonstrating advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NOx) emissions from coal-fired boilers. The project was conducted at Georgia Power Company`s Plant Hammond Unit 4 located near Rome, Georgia. The technologies demonstrated at this site include Foster Wheeler Energy Corporation`s advanced overfire air system and Controlled Flow/Split Flame low NOx burner. The primary objective of the demonstration at Hammond Unit 4 was to determine the long-term effects of commercially available wall-fired low NOx combustion technologies on NOx emissions and boiler performance. Short-term tests of each technology were also performed to provide engineering information about emissions and performance trends. A target of achieving fifty percent NOx reduction using combustion modifications was established for the project. Short-term and long-term baseline testing was conducted in an {open_quotes}as-found{close_quotes} condition from November 1989 through March 1990. Following retrofit of the AOFA system during a four-week outage in spring 1990, the AOFA configuration was tested from August 1990 through March 1991. The FWEC CF/SF low NOx burners were then installed during a seven-week outage starting on March 8, 1991 and continuing to May 5, 1991. Following optimization of the LNBs and ancillary combustion equipment by FWEC personnel, LNB testing commenced during July 1991 and continued until January 1992. Testing in the LNB+AOFA configuration was completed during August 1993. This report provides documentation on the design criteria used in the performance of this project as it pertains to the scope involved with the low NOx burners and advanced overfire systems.

NONE

1998-01-01T23:59:59.000Z

405

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NOx) emissions from coal-fired boilers. Technical progress report, fourth quarter, 1994, October 1994--December 1994  

Science Conference Proceedings (OSTI)

This quarterly report discusses the technical progress of an innovative Clean Coal Technology (ICCT) demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NOx) emissions from coal-fired boilers. The project is being conducted at Georgia Power Company`s Plant Hammond Unit 4 located near Rome, Georgia. The primary goal of this project is the characterization of the low NOx combustion equipment through the collection and analysis of long-term emissions data. The project provides a stepwise evaluation of the following NOx reduction technologies: Advanced overfire air (AOFA), Low NOx burners (LNB), LNB with AOFA, and Advanced Digital Controls and Optimization Strategies. The project has completed the baseline, AOFA, LNB, and LNB+AOFA test segments, fulfilling all testing originally proposed to DOE. Analysis of the LNB long-term data collected show the full load NOx emission levels to be near 0.65 lb/MBtu. This NOx level represents a 48 percent reduction when compared to the baseline, full load value of 1.24 lb/MBtu. These reductions were sustainable over the long-term test period and were consistent over the entire load range. Full load, fly ash LOI values in the LNB configuration were near 8 percent compared to 5 percent for baseline. Results from the LNB+AOFA phase indicate that full load NOx emissions are approximately 0.40 lb/MBtu with a corresponding fly ash LOI value of near 8 percent. Although this NOx level represents a 67 percent reduction from baseline levels, a substantial portion of the incremental change in NOx emissions between the LNB and LNB+AOFA configurations was the result of operational changes and not the result of the AOFA system. Phase 4 of the project is now underway.

NONE

1995-09-01T23:59:59.000Z

406

500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Technical progress report, third quarter 1994, July 1994--September 1994  

Science Conference Proceedings (OSTI)

This quarterly report discusses the technical progress of an Innovative Clean Coal Technology (ICCT) demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NOx) emissions from coal-fired boilers. The project is being conducted at Georgia Power Company`s Plant Hammond Unit 4 located near Rome, Georgia. The primary goal of this project is the characterization of the low NOx combustion equipment through the collection and analysis of long-term emissions data. A target of achieving fifty percent NOx reduction using combustion modifications has been established for the project. The project provides a stepwise evaluation of the following NOx reduction technologies: Advanced overfire air (AOFA), Low NOx burners (LNB), LNB, with AOFA, and Advanced Digital Controls and Optimization Strategies. Baseline, AOFA, LNB, and LNB plus AOFA test segments have been completed. Based on a preliminary analysis, approximately 17 percent of the incremental change in NOx emissions between the LNB and LNB+AOFA configurations is the result of AOFA, the balance of the NOx reduction resulting from other operational adjustments. Preliminary diagnostic testing was conducted during August and September. The purpose of these tests was to determine the emissions and performance characteristics of the unit prior to activation of the advanced control/optimization strategies. Short-term, full load NOx emissions were near 0.47 lb/MBtu, slightly higher than that seen during the LNB+AOFA test phase. Long-term NO{sub x} emissions for this quarter averaged near 0.41 lb/MBtu. Due to turbine problems, a four week outage has been planned for Hammond 4 starting October 1. Two on-line carbon-in-ash monitors are being installed at Hammond Unit 4 as part of the Wall-Fired Project. These monitors will be evaluated as to their accuracy, repeatability, reliability, and serviceability.

NONE

1995-09-01T23:59:59.000Z

407

The magnetohydrodynamics Coal-Fired Flow Facility  

DOE Green Energy (OSTI)

In this quarterly technical progress report, UTSI summarizes the results of a multi-task research and development project directed toward the development of the technology for the commercialization of the steam bottoming plant for the MHD steam combined cycle power plant. The report covers the final test in a 2000-hour proof-of-concept (POC) test series on eastern coal, the plans and progress for the facility modifications and the conduct of the POC tests to be conducted with western coal. Results summarized in the report include chloride emissions from the particle removal (ESP/BH) processes, nitrogen and sulfur oxide emissions for various tests conditions, measurements of particulate control efficiency and management of the facility holding ponds during testing. Activities relating to corrosion and deposition probe measurements during testing and the fouling of heat transfer tubes and interaction with sootblowing cycles are summarized. The performance of both UTSI and Mississippi State University (MSU) advanced diagnostic systems is reported. Significant administrative and contractual actions are included. 2 refs., 28 figs., 7 tabs.

Not Available

1991-07-01T23:59:59.000Z

408

Coal-Fired Fluidized Bed Combustion Cogeneration  

E-Print Network (OSTI)

The availability of an environmentally acceptable multifuel technology, such as fluidized bed combustion, has encouraged many steam producers/ users to investigate switching from oil or gas to coal. Changes in federal regulations encouraging cogeneration have further enhanced the economic incentives for primary fuel switching. However, this addition of cogeneration to the fuel conversion analysis considerably complicates the investigation. A system design for cogeneration of steam and electricity at a nominal 40,000 pound per hour capacity utilizing fluidized bed combustion is described. The basic system incorporates silo storage of coal, ash, and limestone with dense phase conveying. The system generates power utilizing either a backpressure turbine or a condensing turbine with steam extraction. Three case studies performed for specific end users are presented. The interaction among plant steam requirements, rate purchase structure, and electrical energy buy back rate is discussed. How these factors interact determine the final design and the choice of fuels is illustrated. Because the decision to switch fuel, as well as to cogenerate, is usually economically motivated, an in-depth understanding of the steam/electrical needs and interactions is critical. How these considerations are integrated in the system and the effect they have on the monetary returns are discussed. Electric rate agreements vary significantly from one state to another. Therefore, the examples selected are intended to provide, insight into this variability. For example, one rate structure encourages solid fuel cogeneration. The second is a block structure with low sell back rates making cogeneration difficult to justify. How these rate schedules affected the recommended design illustrates that the system selection is very important.

Thunem, C.; Smith, N.

1985-05-01T23:59:59.000Z

409

METC research on coal-fired diesels  

DOE Green Energy (OSTI)

The METC in-house Coal-Fueled Diesel Research project is part of the overall DOE effort to develop a technology base for diesel engines capable of operating on coal, shale oil or low-cost coal-derived fuels. The in-house effort started in 1985 as a test-bed for coal-derived liquid fuels and will end this fiscal year with the successful completion of METC`s diesel R&D program. Currently METC in-house research and development efforts focus on pilot chamber combustion in METC`s coal-water slurry (CWS) fueled diesel engine. A novel pilot chamber for a direct-injected, coal-fueled diesel engine has been designed and is being tested in METC`s single cylinder research diesel engine. The pilot chamber configuration allows for operation at extended load and speed conditions using 100 percent CWS and no other pilot fuel. The concept involves the use of a small volume chamber exterior to the main cylinder in which approximately 5 percent of the total fuel energy at full load conditions is injected. Lower NO{sub X} levels may be obtained due to leaner burning as well as broader stable performance using only CWS fuel.

McMillian, M.H. [USDOE Morgantown Energy Technology Center, WV (United States); Robey, E.H.; Addis, R.E. [EG and G Washington Analytical Services Center, Inc., Morgantown, WV (United States)

1993-11-01T23:59:59.000Z

410

Biomass Cofiring in Coal-Fired Boilers  

DOE Green Energy (OSTI)

Cofiring biomass-for example, forestry residues such as wood chips-with coal in existing boilers is one of the easiest biomass technologies to implement in a federal facility. The current practice is to substitute biomass for up to 20% of the coal in the boiler. Cofiring has many benefits: it helps to reduce fuel costs as well as the use of landfills, and it curbs emissions of sulfur oxide, nitrogen oxide, and the greenhouse gases associated with burning fossil fuels. This Federal Technology Alert was prepared by the Department of Energy's Federal Energy Management Program to give federal facility managers the information they need to decide whether they should pursue biomass cofiring at their facilities.

Not Available

2004-06-01T23:59:59.000Z

411

NETL F 451.1-1/1 Categorical Exclusion (CX) Designation Form  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

URS FE DE-FE0005654 Existing Plants Division 11 Bruce Lani 10012010-09302013 Buda, Hays County, Texas Evaluation of Concentrated Piperazine for CO2 Capture from Coal-Fired Flue...

412

U.S. DEPARTMENT OF ENERGY - NETL CATEGORICAL EXCLUSION (CX) DESIGNATIO...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Division 2010 Bruce W. Lani December 1,2009-June 30,2012 Lehigh University, Bethlehem, PA THERMAL INTEGRATION OF CO2 COMPRESSION PROCESSES WITH COAL-FIRED POWER PLANTS EQUIPPED...

413

Howe, Bruce M. Bruce M. Howe  

E-Print Network (OSTI)

-n-line Students ! #12;Philippines (Moro Gulf) Solomon Islands Marshall Islands Line Islands Hawaiian Islands-MS Sagittal otolith Trace elements core section Core section (~ 3 mo) #12;Solomon Is. Philippines Marshall Is Kauai Hawaii 18O 13C -12 -11 -10 -9 -8 Hawaii 23% Oahu 12% Maui 32% Kauai 33% Collection locations

Frandsen, Jannette B.

414

Fishman, B., Pinkard, N., & Bruce, C. (1998). Preparing schools for curricular reform: Planning for Technology vs. Technology Planning. In A. Bruckman, M. Guzdial, J. Kolodner, & A. Ram (Eds.), International Conference on the  

E-Print Network (OSTI)

Fishman, B., Pinkard, N., & Bruce, C. (1998). Preparing schools for curricular reform: Planning for Technology vs. Technology Planning. In A. Bruckman, M. Guzdial, J. Kolodner, & A. Ram (Eds.), International for Curricular Reform: Planning for Technology vs. Technology Planning Barry Fishman, Nichole Pinkard, Chris

Fishman, Barry

415

Mansfield, Massachusetts: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

4326°, -71.2189405° 4326°, -71.2189405° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.0334326,"lon":-71.2189405,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

416

Mansfield, Ohio: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

°, -82.5154471° °, -82.5154471° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":40.75839,"lon":-82.5154471,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

417

Innovative Clean Coal Technology (ICCT): 500 MW demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. Phase 3A, Low NO{sub x} burner tests  

SciTech Connect

This Phase 3A test report summarizes the testing activities and results for the third testing phase of an Innovative Clean Coal Technology (ICCT) demonstration of advanced wall-fired combustion techniques for the reduction of nitrogen oxide (NO{sub x}) emissions from coal-fired boilers. The project is being conducted at Georgia Power Company`s Plant Hammond Unit 4 located near Rome, Georgia. The primary goal of this project is the characterization of the low NO{sub x} combustion equipment through the collection and analysis of long-term emissions data. Described in this report are the test plans, data measurements, and data analyses performed during the Phase 3A effort. The present report also contains sufficient background material to provide an understanding of the overall program scope, the relationship of Phase 3A to the overall program, the testing methodologies, testing procedures, and unit configuration. Results from 66 short-term tests indicate increasing NO{sub x} emissions over the load range ranging from 0.5 lb/MBtu at 300 NM to around 0.65 lb/MBtu at 480 MW. Fly ash loss-on-ignition (LOI) for these loads ranged from 5.4 to 8.6 percent. Long-term test results indicated high load (480 MW) NO{sub x} emissions of approximately 0.65 lb/MBtu. At the 300 MW mid load point, the emissions dropped to 0.47 lb/MBtu which is slightly lower than the 0.50 lb/MBtu shown for the short-term data. The annual and 30-day average achievable NO{sub x} emissions were determined to be 0.55 and 0.64 lb/MBtu, respectively, for the load scenario experienced during the Phase 3A, long-term test period. Based on the long-term test results for Phase 3A, at full-load the low NO{sub x} burners (LNB) retrofit resulted in a NO{sub x} reduction of 48 percent from baseline, while at 300 MW the reduction was approximately 50 percent. A series of tests was also conducted to evaluate the effects of various burner equipment settings and mill coal flow biasing on both NO{sub x} and LOI emissions.

Not Available

1993-03-15T23:59:59.000Z

418

Capturing Carbon from Existing Coal-Fired Power Plants  

NLE Websites -- All DOE Office Websites (Extended Search)

CEP April 2009 www.aiche.org/cep 33 CEP April 2009 www.aiche.org/cep 33 DOE's National Energy Technology Laboratory is spearheading R&D on a variety of post-combustion and oxy-combustion technologies to cost-effectively achieve 90% CO 2 capture. Jared P. Ciferno Timothy E. Fout U.S. Dept. of Energy, National Energy Technology Laboratory Andrew P. Jones James T. Murphy Science Applications International Corp. C oal-fi red power plants generate about half of the electricity in the United States today, and will con- tinue to be a major source of energy for the fore- seeable future. The U.S. Dept. of Energy's (DOE) Energy Information Administration (EIA) projects that the nation's 300+ gigawatts (GW) of coal-fi red electricity-generating capacity currently in operation will increase to more than

419

Biomass Cofiring in Coal-Fired Boilers - Federal Technology Alert  

NLE Websites -- All DOE Office Websites (Extended Search)

when needed. Unlike other renewable energy technologies like those based on solar and wind resources, biomass-based systems are available whenever they are needed. This helps...

420

Trace element speciation under coal fired power station conditions  

Science Conference Proceedings (OSTI)

Coal combustion from power stations is one of the largest contributors of potentially toxic trace elements to the environment. Some trace elements may be released in range of valencies, often with varying toxicity and bioavailability. Hence, determination ... Keywords: arsenic, chromium, coal combustion, mercury, selenium, speciation, trace elements

Pushan Shah; Vladimir Strezov; Peter F. Nelson

2007-05-01T23:59:59.000Z

Note: This page contains sample records for the topic "bruce mansfield coal-fired" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Transmission upgrades compensate for coal-fired retirements in ...  

U.S. Energy Information Administration (EIA)

Biofuels: Ethanol & Biodiesel ... improve the flow of power between regions. PJM has an overall reserve margin of 29%, 13 percentage points above its target, ...

422

Rail traffic reflects more oil production, less coal-fired ...  

U.S. Energy Information Administration (EIA)

Petroleum & Other Liquids. Crude oil, gasoline, heating oil, diesel, propane, and other liquids including biofuels and natural gas liquids. Natural Gas

423

NOx Control Options and Integration for US Coal Fired Boilers  

SciTech Connect

This is the sixteenth Quarterly Technical Report for DOE Cooperative Agreement No: DEFC26-00NT40753. The goal of the project is to develop cost effective analysis tools and techniques for demonstrating and evaluating low NOx control strategies and their possible impact on boiler performance for boilers firing US coals. The Electric Power Research Institute (EPRI) is providing co-funding for this program. During an unplanned outage, damage occurred to the electrochemical noise corrosion probes installed at the AEP Gavin plant; testing is expected to resume in August. The KEMCOP corrosion coupons were not affected by the unplanned outage; the coupons were removed and sent for analysis. BYU conducted a series of tests before the ISSR lab was relocated. Ammonia adsorption experiments provided clear evidence of the types of acidic sites present on catalyst surfaces. Data collected this quarter indicate that surface sulfation decreases Lewis acid site concentrations for all catalysts thus far studied, confirming that catalytic activity under commercial coal-based SCR conditions occurs primarily on Br{o}nsted acid sites and would be susceptible to basic impurities such as alkali and alkaline earth oxides, chlorides, and sulfates. SCR activity tests based on MS analysis showed that increasing sulfation generally increases NO reduction activity for both 0% and 1% vanadia catalysts. During this quarter, the slipstream reactor at Rockport operated for 720 hours on flue gas. Catalyst exposure time reached 4500 hours since installation. The reactor is out of service at the Rockport plant and plans are being made to move it to the Gadsden Plant. At Gadsden, modifications have begun in preparation for installation of the slipstream reactor next quarter.

Mike Bockelie; Kevin Davis; Temi Linjewile; Connie Senior; Eric Eddings; Kevin Whitty; Larry Baxter; Calvin Bartholomew; William Hecker; Stan Harding

2004-06-30T23:59:59.000Z

424

Figure 107. Cumulative coal-fired generating capacity additions ...  

U.S. Energy Information Administration (EIA)

Dry sorbent injection sytems Reference No GHG Concern Released: April 17, 2013 $8.84 $42.71 $50.34 $25.70 $54.09 ... Wells, Peggy Created Date: 4/13/2013 10:25:20 PM