Powered by Deep Web Technologies
Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


1

Report of the Building 9207 air bag test  

Science Conference Proceedings (OSTI)

As part of a major testing program now underway at the Department of Energy`s (DOE) Oak Ridge Y-12 Plant, managed by Martin Marietta Energy Systems, Inc. (MMES), a full-scale air bag test was conducted in Building 9207. The test program, supported and managed by the Center for Natural Phenomena Engineering (CNPE), is intended to determine the stiffness and strength of unreinforced hollow clay tile walls (HCTVS) in order to more accurately analyze and predict the response of buildings containing these type of walls, especially when subjected to seismic and high wind loadings. The air bag test was a very large undertaking that started more than a year before the test was actually performed. Preparation for the test included the following activities: (1) preparation of the wall and the adjacent building areas; (2) design and field fabrication of test supporting structures; (3) procurement of equipment and instrumentation; (4) development of supporting test procedures and checklists; (5) installation of over seventy linear variable differential transformers (LVDTs) and strain gages; (6) development of computer programs for use in the data acquisition systems; (7) extensive review into the existing engineering literature; (8) discussions with researchers with prior experience performing air bag tests; (9) coordination with the building operators; (10) plant safety reviews; and (11) dry runs of the test itself.

Huff, T.E.; Fricke, K.E.; Jones, W.D.

1992-12-01T23:59:59.000Z

2

Hybrid: Braking  

NLE Websites -- All DOE Office Websites (Extended Search)

button highlighted Stopped Button subbanner graphic: gray bar BRAKING: PART 1 Regenerative braking converts otherwise wasted energy from braking into electricity and stores it in...

3

Hybrid: Braking  

NLE Websites -- All DOE Office Websites (Extended Search)

Button Stopped button highlighted subbanner graphic: gray bar Button Stopped button highlighted subbanner graphic: gray bar STOPPED When the vehicle is stopped, such as at a red light, the gasoline engine and electric motor shut off automatically so that energy is not wasted in idling. The battery continues to power auxillary systems, such as the air conditioning and dashboard displays. stage graphic: vertical blue rule Main stage: See through car with battery, engine, and electric motor visible. The car is stopped at an intersection. Main stage: See through car with battery, engine, and electric motor visible. The car is stopped at an intersection. Battery: The battery stores energy generated from the gasoline engine or, during regenerative braking, from the electric motor. Since the battery helps power the vehicle, it is larger and holds much more energy than batteries used to start conventional vehicles. Main stage: See through car with battery, engine, and electric motor visible. The car is stopped at an intersection.

4

Hybrid: Braking  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Button Stopped button highlighted subbanner graphic: gray bar Button Stopped button highlighted subbanner graphic: gray bar STOPPED When the vehicle is stopped, such as at a red light, the gasoline engine and electric motor shut off automatically so that energy is not wasted in idling. The battery continues to power auxillary systems, such as the air conditioning and dashboard displays. stage graphic: vertical blue rule Main stage: See through car with battery, engine, and electric motor visible. The car is stopped at an intersection. Main stage: See through car with battery, engine, and electric motor visible. The car is stopped at an intersection. Battery: The battery stores energy generated from the gasoline engine or, during regenerative braking, from the electric motor. Since the battery helps power the vehicle, it is larger and holds much more energy than batteries used to start conventional vehicles. Main stage: See through car with battery, engine, and electric motor visible. The car is stopped at an intersection.

5

Commercial Motor Vehicle Brake Assessment Tools  

E-Print Network (OSTI)

Commercial Motor Vehicle Brake Assessment Tools Commercial Motor Vehicle Roadside Technology Corridor Safety Technology Showcase October 14, 2010 Commercial Motor Vehicle Roadside Technology Corridor #12;Overview · Commercial Motor Vehicle (CMV) Air Brake System · North American Standard Level-1

6

Gravity brake  

DOE Patents (OSTI)

A mechanical gravity brake that prevents hoisted loads within a shaft from free-falling when a loss of hoisting force occurs. A loss of hoist lifting force may occur in a number of situations, for example if a hoist cable were to break, the brakes were to fail on a winch, or the hoist mechanism itself were to fail. Under normal hoisting conditions, the gravity brake of the invention is subject to an upward lifting force from the hoist and a downward pulling force from a suspended load. If the lifting force should suddenly cease, the loss of differential forces on the gravity brake in free-fall is translated to extend a set of brakes against the walls of the shaft to stop the free fall descent of the gravity brake and attached load.

Lujan, Richard E. (Santa Fe, NM)

2001-01-01T23:59:59.000Z

7

Braking system  

DOE Patents (OSTI)

A balanced braking system comprising a plurality of braking assemblies located about a member to be braked. Each of the braking assemblies consists of a spring biased piston of a first material fitted into a body of a different material which has a greater contraction upon cooling than the piston material. The piston is provided with a recessed head portion over which is positioned a diaphragm and forming a space therebetween to which is connected a pressurized fluid supply. The diaphragm is controlled by the fluid in the space to contact or withdraw from the member to be braked. A cooling means causes the body within which the piston is fitted to contract more than the piston, producing a tight shrink fit therebetween. The braking system is particularly applicable for selectively braking an arbor of an electron microscope which immobilizes, for example, a vertically adjustable low temperature specimen holder during observation. The system provides balanced braking forces which can be easily removed and re-established with minimal disturbance to arbor location.

Norgren, D.U.

1982-09-23T23:59:59.000Z

8

CMV Brake Wear and Performance Test Little is known about the brake  

E-Print Network (OSTI)

inspections were due to brake defects. Additionally, brake maintenance and repair present a significant cost Center for Transportation Analysis (CTA) Research Areas Aviation Safety Air Traffic Management Analysis Environmental Policy Analysis Highway Safety Intelligent Transportation Systems Logistics Management Supply

9

Paper Bags  

NLE Websites -- All DOE Office Websites (Extended Search)

Paper Bags Paper Bags Nature Bulletin No. 438-A December 18, 1971 Forest Preserve District of Cook County George W. Dunne, President Roland F. Eisenbeis, Supt. of Conservation PAPER BAGS Paper bags may strike you as a peculiar topic for a Christmas bulletin. In previous years we chose reindeer, turkeys, holly, mistletoe, and other appropriate subjects. But paper bags also have a part in your celebration of Christmas: the ingredients for your dinner, many of them packaged in bags, come from the stores in grocery bags or shopping bags of heavy paper. Further, the patent for the first machine to make them was issued in 1852 to a 35-year-old schoolmaster, named Francis Wolle, in Bethlehem, Pennsylvania . Bethlehem is a big town now, famous for its steel mills, but a hundred years ago it was a hamlet settled by devout Moravians of German origin. In those days there were "general stores" that sold groceries, meats, hardware, harness, clothing and "notions" such as pins, needles, thread, ribbons and buttons. Everything came to them in bulk -- barrels, keys, cloth sacks, and crates. Doling out small quantities to customers was a vexing problem. Some people came with baskets, or with "tote bags" of jute; others begged for a sheet of brown wrapping paper but paper was scarce. Even newspapers were scarce.

10

Hybrid: Braking  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

1 1 Regenerative braking converts otherwise wasted energy from braking into electricity and stores it in the battery. In regenerative braking, the electric motor is reversed so that, instead of using electricity to turn the wheels, the rotating wheels turn the motor and create electricity. Using energy from the wheels to turn the motor slows the vehicle down. Go to next… stage graphic: vertical blue rule Main stage: See through car with battery, engine, and electric motor visible. The car is decelerating. There are arrows flowing from the front wheels to the electric motor to the battery. Main stage: See through car with battery, engine, and electric motor visible. The car is decelerating. There are arrows flowing from the front wheels to the electric motor to the battery.

11

Hybrid: Braking  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

2 2 If additional stopping power is needed, conventional friction brakes (e.g., disc brakes) are also applied automatically. Go back… stage graphic: vertical blue rule Main stage: See through car with battery, engine, and electric motor visible. The car is stopped at an intersection. Main stage: See through car with battery, engine, and electric motor visible. The car is stopped at an intersection. Battery: The battery stores energy generated from the gasoline engine or, during regenerative braking, from the electric motor. Since the battery helps power the vehicle, it is larger and holds much more energy than batteries used to start conventional vehicles. Main stage: See through car with battery, engine, and electric motor visible. The car is stopped at an intersection.

12

Full Hybrid: Braking  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Braking button highlighted Stopped button Braking button highlighted Stopped button BRAKING PART 1 Regenerative braking converts otherwise wasted energy from braking into electricity and stores it in the battery. In regenerative braking, the electric motor is reversed so that, instead of using electricity to turn the wheels, the rotating wheels turn the motor and create electricity. Using energy from the wheels to turn the motor slows the vehicle down. Go to next… stage graphic: vertical blue rule Main stage: See through car with battery, engine, generator, power split device, and electric motor visible. The car is decelerating. There are arrows flowing from the front wheels to the power split device to the electric motor to the battery. Main stage: See through car with battery, engine, generator, power split device, and electric motor visible. The car is decelerating. There are arrows flowing from the front wheels to the power split device to the electric motor to the battery.

13

Vehicle brake testing system  

SciTech Connect

This invention relates to a force measuring system capable of measuring forces associated with vehicle braking and of evaluating braking performance. The disclosure concerns an invention which comprises a first row of linearly aligned plates, a force bearing surface extending beneath and beside the plates, vertically oriented links and horizontally oriented links connecting each plate to a force bearing surface, a force measuring device in each link, a transducer coupled to each force measuring device, and a computing device coupled to receive an output signal from the transducer indicative of measured force in each force measuring device. The present invention may be used for testing vehicle brake systems.

Stevens, Samuel S [Harriman, TN; Hodgson, Jeffrey W [Lenoir City, TN

2002-11-19T23:59:59.000Z

14

Svendborg Brakes | Open Energy Information  

Open Energy Info (EERE)

energy Product Denmark-based manufacturer of braking systems for the wind industry, as well as for the oil sector. References Svendborg Brakes1 LinkedIn Connections CrunchBase...

15

Combined hydraulic and regenerative braking system  

DOE Patents (OSTI)

A combined hydraulic and regenerative braking system and method for an electric vehicle is disclosed. The braking system is responsive to the applied hydraulic pressure in a brake line to control the braking of the vehicle to be completely hydraulic up to a first level of brake line pressure, to be partially hydraulic at a constant braking force and partially regenerative at a linearly increasing braking force from the first level of applied brake line pressure to a higher second level of brake line pressure, to be partially hydraulic at a linearly increasing braking force and partially regenerative at a linearly decreasing braking force from the second level of applied line pressure to a third and higher level of applied line pressure, and to be completely hydraulic at a linearly increasing braking force from the third level to all higher applied levels of line pressure.

Venkataperumal, R.R.; Mericle, G.E.

1979-08-09T23:59:59.000Z

16

Combined hydraulic and regenerative braking system  

DOE Patents (OSTI)

A combined hydraulic and regenerative braking system and method for an electric vehicle, with the braking system being responsive to the applied hydraulic pressure in a brake line to control the braking of the vehicle to be completely hydraulic up to a first level of brake line pressure, to be partially hydraulic at a constant braking force and partially regenerative at a linearly increasing braking force from the first level of applied brake line pressure to a higher second level of brake line pressure, to be partially hydraulic at a linearly increasing braking force and partially regenerative at a linearly decreasing braking force from the second level of applied line pressure to a third and higher level of applied line pressure, and to be completely hydraulic at a linearly increasing braking force from the third level to all higher applied levels of line pressure.

Venkataperumal, Rama R. (Troy, MI); Mericle, Gerald E. (Mount Clemens, MI)

1981-06-02T23:59:59.000Z

17

Regenerative braking device  

DOE Patents (OSTI)

Disclosed are several embodiments of a regenerative braking device for an automotive vehicle. The device includes a plurality of rubber rollers (24, 26) mounted for rotation between an input shaft (14) connectable to the vehicle drivetrain and an output shaft (16) which is drivingly connected to the input shaft by a variable ratio transmission (20). When the transmission ratio is such that the input shaft rotates faster than the output shaft, the rubber rollers are torsionally stressed to accumulate energy, thereby slowing the vehicle. When the transmission ratio is such that the output shaft rotates faster than the input shaft, the rubber rollers are torsionally relaxed to deliver accumulated energy, thereby accelerating or driving the vehicle.

Hoppie, Lyle O. (Birmingham, MI)

1982-01-12T23:59:59.000Z

18

Variable ratio regenerative braking device  

DOE Patents (OSTI)

Disclosed is a regenerative braking device (10) for an automotive vehicle. The device includes an energy storage assembly (12) having a plurality of rubber rollers (26, 28) mounted for rotation between an input shaft (36) and an output shaft (42), clutches (38, 46) and brakes (40, 48) associated with each shaft, and a continuously variable transmission (22) connectable to a vehicle drivetrain and to the input and output shafts by the respective clutches. The rubber rollers are torsionally stressed to accumulate energy from the vehicle when the input shaft is clutched to the transmission while the brake on the output shaft is applied, and are torsionally relaxed to deliver energy to the vehicle when the output shaft is clutched to the transmission while the brake on the input shaft is applied. The transmission ratio is varied to control the rate of energy accumulation and delivery for a given rotational speed of the vehicle drivetrain.

Hoppie, Lyle O. (Birmingham, MI)

1981-12-15T23:59:59.000Z

19

Brake blending strategy for a hybrid vehicle  

DOE Patents (OSTI)

A hybrid electric powertrain system is provided including a transmission for driving a pair of wheels of a vehicle and a heat engine and an electric motor/generator coupled to the transmission. A friction brake system is provided for applying a braking torque to said vehicle. A controller unit generates control signals to the electric motor/generator and the friction brake system for controllably braking the vehicle in response to a drivers brake command. The controller unit determines and amount of regenerative torque available and compares this value to a determined amount of brake torque requested for determining the control signals to the electric motor/generator and the friction brake system.

Boberg, Evan S. (Hazel Park, MI)

2000-12-05T23:59:59.000Z

20

Improved braking torque generation capacity of an eddy current brake with time varying magnetic fields: A numerical study  

Science Conference Proceedings (OSTI)

Eddy current brakes (ECB) are electrically controlled and non-contact actuators used as assistive brakes in vehicles. ECBs exhibit insufficient generated braking torque at low speeds. In order to overcome this, the use of AC magnetic fields with fixed ... Keywords: Automotive applications, Brake-by-wire, Eddy current brakes, Finite element analysis, Time-varying magnetic field

Kerem Karakoc; Edward J. Park; Afzal Suleman

2012-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


21

Development of a Novel Air Hybrid Engine.  

E-Print Network (OSTI)

??An air hybrid vehicle is an alternative to the electric hybrid vehicle that stores the kinetic energy of the vehicle during braking in the form (more)

Fazeli, Amir

2011-01-01T23:59:59.000Z

22

Commercial Motor Vehicle Brake-Related Research  

E-Print Network (OSTI)

Commercial Motor Vehicle Brake-Related Research Commercial Motor Vehicle Roadside Technology Corridor Safety Technology Showcase October 14, 2010 Commercial Motor Vehicle Roadside Technology Corridor

23

Team Bug Bag Biogas For Nicaragua  

E-Print Network (OSTI)

Team Bug Bag Biogas For Nicaragua Project Recap The task for Team Bug Bag was to create for under $100 (USD), and be able to produce biogas that could boil water for a thirty minute time period

Demirel, Melik C.

24

Testing of Replacement Bag Material  

Science Conference Proceedings (OSTI)

Recently, the FB-Line bagout material was changed to simplify the processing of sand, slag, and crucible.The results of the strength tests and the outgassing measurements and calculations demonstrate that the proposed replacement nylon bag materials (HRMP and orange anti-static material) are acceptable substitutes for LDPE and the original nylon with respect to mechanical properties.

Laurinat, J.E.

1998-11-03T23:59:59.000Z

25

Microsoft Word - ford99.html  

NLE Websites -- All DOE Office Websites (Extended Search)

FM Stereo Radio Tilt Steering Wheel Cabin Heat Dual Air Bags Power Steering (electro-hydraulic) Power Brakes Four Wheel Disc Brakes Four Wheel Anti-Lock Brakes Regenerative...

26

Multidisciplinary design optimization of an automotive magnetorheological brake design  

Science Conference Proceedings (OSTI)

This paper presents the development of a new electromechanical brake system using magnetorheological (MR) fluid. The proposed brake system consists of rotating disks immersed in a MR fluid and enclosed in an electromagnet, where the yield stress of the ... Keywords: Automotive brake, Computational fluid dynamics, Electric brake actuator, Finite element analysis, Magnetorheological fluid, Multidisciplinary design optimization

Edward J. Park; Luis Falco da Luz; Afzal Suleman

2008-02-01T23:59:59.000Z

27

The Application of Fuzzy Logic in Regenerative Braking of EV  

Science Conference Proceedings (OSTI)

Regenerative braking can improve energy usage efficiency and prolong the driving distance of electric vehicle per charge, effectively. In the paper, we design a sugenos fuzzy logic controller which has four inputs including drivers braking ... Keywords: regenerative braking, fuzzy logic control, braking force distribution, ADVISOR

Zijian Zhang; Guoqing Xu; Weimin Li; Liang Zheng

2010-08-01T23:59:59.000Z

28

Method and apparatus for wind turbine braking  

DOE Patents (OSTI)

A method for braking a wind turbine including at least one rotor blade coupled to a rotor. The method includes selectively controlling an angle of pitch of the at least one rotor blade with respect to a wind direction based on a design parameter of a component of the wind turbine to facilitate reducing a force induced into the wind turbine component as a result of braking.

Barbu, Corneliu (Laguna Hills, CA); Teichmann, Ralph (Nishkayuna, NY); Avagliano, Aaron (Houston, TX); Kammer, Leonardo Cesar (Niskayuna, NY); Pierce, Kirk Gee (Simpsonville, SC); Pesetsky, David Samuel (Greenville, SC); Gauchel, Peter (Muenster, DE)

2009-02-10T23:59:59.000Z

29

PNNL Nanoscale Research Safety Program Brown Bag  

NLE Websites -- All DOE Office Websites (Extended Search)

PNNL's Nanoscale Research Safety Program Brown Bag Carbon nanotube research is a critical research capability at Pacifi c North- west National Laboratory (Digisource) Do you work...

30

Adaptive controller for regenerative and friction braking system  

DOE Patents (OSTI)

A regenerative and friction braking system for a vehicle having one or more roadwheels driven by an electric traction motor includes a driver responsive device for producing a brake demand signal having a magnitude corresponding to the level of braking force selected by the driver and friction and regenerative brakes operatively connected with the roadwheels of the vehicle. A system according to this invention further includes control means for operating the friction and regenerative braking subsystems so that maximum brake torques sustainable by the roadwheels of the vehicle without skidding or slipping will not be exceeded.

Davis, Roy I. (Ypsilanti, MI)

1990-01-01T23:59:59.000Z

31

Adaptive controller for regenerative and friction braking system  

DOE Patents (OSTI)

A regenerative and friction braking system for a vehicle having one or more road wheels driven by an electric traction motor includes a driver responsive device for producing a brake demand signal having a magnitude corresponding to the level of braking force selected by the driver and friction and regenerative brakes operatively connected with the road wheels of the vehicle. A system according to this invention further includes control means for operating the friction and regenerative braking subsystems so that maximum brake torques sustainable by the road wheels of the vehicle without skidding or slipping will not be exceeded. 8 figs.

Davis, R.I.

1990-10-16T23:59:59.000Z

32

Model and Simulation of a Super-capacitor Braking Energy Recovery System for Urban Railway Vehicles  

Science Conference Proceedings (OSTI)

In this paper, a braking energy recovery system based on super-capacitor was presented. The method use super-capacitor and the conventional braking resistance constitute a new braking unit to realize the regenerative energy recovery, when braking, braking ... Keywords: Urban railway transportation, regeneration braking, super-capacitor, energy recovery, electric traction

Chen Xiao-li; Yang Jian; Fang Yu

2010-08-01T23:59:59.000Z

33

Electric vehicle regenerative antiskid braking and traction control system  

DOE Patents (OSTI)

An antiskid braking and traction control system for an electric or hybrid vehicle having a regenerative braking system operatively connected to an electric traction motor, and a separate hydraulic braking system includes one or more sensors for monitoring present vehicle parameters and a processor, responsive to the sensors, for calculating vehicle parameters defining the vehicle behavior not directly measurable by the sensors and determining if regenerative antiskid braking control, requiring hydrualic braking control, or requiring traction control are required. The processor then employs a control strategy based on the determined vehicle state and provides command signals to a motor controller to control the operation of the electric traction motor and to a brake controller to control fluid pressure applied at each vehicle wheel to provide the appropriate regenerative antiskid braking control, hydraulic braking control, and traction control.

Cikanek, Susan R. (Wixom, MI)

1995-01-01T23:59:59.000Z

34

Electric vehicle regenerative antiskid braking and traction control system  

DOE Patents (OSTI)

An antiskid braking and traction control system for an electric or hybrid vehicle having a regenerative braking system operatively connected to an electric traction motor, and a separate hydraulic braking system includes one or more sensors for monitoring present vehicle parameters and a processor, responsive to the sensors, for calculating vehicle parameters defining the vehicle behavior not directly measurable by the sensors and determining if regenerative antiskid braking control, requiring hydraulic braking control, or requiring traction control are required. The processor then employs a control strategy based on the determined vehicle state and provides command signals to a motor controller to control the operation of the electric traction motor and to a brake controller to control fluid pressure applied at each vehicle wheel to provide the appropriate regenerative antiskid braking control, hydraulic braking control, and traction control. 10 figs.

Cikanek, S.R.

1995-09-12T23:59:59.000Z

35

The Research of Traction Motor Energy-Saving Regenerative Braking Control Technology  

Science Conference Proceedings (OSTI)

In all the motor braking control systems, regenerative braking is the only way of energy-saving braking control mode. It can convert dynamic energy which generate during braking period into electric energy, then return to the grid. In this paper, through ... Keywords: regenerative braking, traction motor, direct torque, stator flux, slip frequency

Yuhua Wang; Jianlin Miao; Yuanfang Wei

2010-05-01T23:59:59.000Z

36

Niobium Alloying in Grey Cast Iron for Vehicle Brake Discs  

Science Conference Proceedings (OSTI)

Presentation Title, Niobium Alloying in Grey Cast Iron for Vehicle Brake Discs. Author(s) ... Microtexture Analysis of a Hot Rolled Silicon Electric Steel Niobium

37

Skew estimation of document images using bagging  

Science Conference Proceedings (OSTI)

This paper proposes a general-purpose method for estimating the skew angles of document images. Rather than to derive a skew angle merely from text lines, the proposed method exploits various types of visual cues of image skew available in local image ... Keywords: bagging estimator, document image analysis, floating cascade, radon transform, skew estimation

Gaofeng Meng; Chunhong Pan; Nanning Zheng; Chen Sun

2010-07-01T23:59:59.000Z

38

Braking system for use with an arbor of a microscope  

DOE Patents (OSTI)

A balanced braking system comprising a plurality of braking assemblies located about a member to be braked. Each of the braking assemblies consists of a spring biased piston of a first material fitted into a body of a different material which has a greater contraction upon cooling than the piston material. The piston is provided with a recessed head portion over which is positioned a diaphragm and forming a space therebetween to which is connected a pressurized fluid supply. The diaphragm is controlled by the fluid in the space to contact or withdraw from the member to be braked. A cooling device causes the body within which the piston is fitted to contract more than the piston, producing a tight shrink fit therebetween. The braking system is particularly applicable for selectively braking an arbor of an electron microscope which immobilizes, for example, a vertically adjustable low temperature specimen holder during observation. The system provides balanced braking forces which can be easily removed and re-established with minimal disturbance to arbor location.

Norgren, Duane U. (Orinda, CA)

1984-01-01T23:59:59.000Z

39

TTRDC - Publications - Transforum 10.2 - Plastic Bags  

NLE Websites -- All DOE Office Websites (Extended Search)

From Trash to Treasure: Turning Plastic Bags into Battery Anodes From Trash to Treasure: Turning Plastic Bags into Battery Anodes Vilas Pol and plastic bag research Plastic bags are burned in a vessel at high temperatures. Turning an environmental nuisance into a potential energy solution - now, that's innovation! After much trial and error, Argonne Scholar Vilas Pol has figured out a way to convert those pesky plastic grocery bags into carbon nanotubes, which could be used as components of lithium-ion batteries for many applications, including cars. Plastic bags have taken over the grocery market since they were introduced more than 30 years ago. Billions of them are used around the world each year. The bags are recyclable, but a majority of them still end up in landfills. "They take hundreds of years to decompose," said Pol.

40

Study on Regenerative Brake Method of Hybrid Electric Drive System of Armored Vehicle  

Science Conference Proceedings (OSTI)

Aiming at characteristics of regenerative brake of hybrid electric drive system of tracked armored vehicle, mechanism of regenerative brake by pulse width modulation is in-depth analyzed, motor speed, brake current, feedback current, feedback energy ... Keywords: hybrid electric drive, motor, regenerative brake

Li Hua; Zhong Meng-chun; Zhang Jian; Xu Da; Lin Hai

2011-10-01T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


41

Regenerative braking on bicycles to power LED safety flashers  

E-Print Network (OSTI)

This work develops a method for capturing some of the kinetic energy ordinarily lost during braking on bicycles to power LED safety flashers. The system is designed to eliminate: (a) battery changing in popular LED flashers, ...

Collier, Ian M

2005-01-01T23:59:59.000Z

42

Computational model design and performance estimation in registration brake control  

Science Conference Proceedings (OSTI)

Electric motorcycles are applicable to both toys and real motorcycles, and also is a reference for constructing larger electrical vehicles. A design computational model of regenerative braking control of electric motorcycles and an experimental identification ...

P. S. Pa; S. C. Chang

2009-06-01T23:59:59.000Z

43

Investigation of aerodynamic braking devices for wind turbine applications  

DOE Green Energy (OSTI)

This report documents the selection and preliminary design of a new aerodynamic braking system for use on the stall-regulated AWT-26/27 wind turbines. The goal was to identify and design a configuration that offered improvements over the existing tip brake used by Advanced Wind Turbines, Inc. (AWT). Although the design objectives and approach of this report are specific to aerodynamic braking of AWT-26/27 turbines, many of the issues addressed in this work are applicable to a wider class of turbines. The performance trends and design choices presented in this report should be of general use to wind turbine designers who are considering alternative aerodynamic braking methods. A literature search was combined with preliminary work on device sizing, loads and mechanical design. Candidate configurations were assessed on their potential for benefits in the areas of cost, weight, aerodynamic noise, reliability and performance under icing conditions. As a result, two configurations were identified for further study: the {open_quotes}spoiler-flap{close_quotes} and the {open_quotes}flip-tip.{close_quotes} Wind tunnel experiments were conducted at Wichita State University to evaluate the performance of the candidate aerodynamic brakes on an airfoil section representative of the AWT-26/27 blades. The wind tunnel data were used to predict the braking effectiveness and deployment characteristics of the candidate devices for a wide range of design parameters. The evaluation was iterative, with mechanical design and structural analysis being conducted in parallel with the braking performance studies. The preliminary estimate of the spoiler-flap system cost was $150 less than the production AWT-26/27 tip vanes. This represents a reduction of approximately 5 % in the cost of the aerodynamic braking system. In view of the preliminary nature of the design, it would be prudent to plan for contingencies in both cost and weight.

Griffin, D.A. [R. Lynette & Associates, Seattle, WA (United States)

1997-04-01T23:59:59.000Z

44

A Brown Bag Lunch with EETD Communications Support Resource:...  

NLE Websites -- All DOE Office Websites (Extended Search)

technical writing and editing, and support for large projects such as guidebooks, manuals, and multi-party proposal development. At this informal brown bag lunch,...

45

A Mixed Bag of Aerosols over Northeastern China  

NLE Websites -- All DOE Office Websites (Extended Search)

Mixed Bag of Aerosols over Northeastern China For original submission and image(s), see ARM Research Highlights http:www.arm.govsciencehighlights Research Highlight...

46

Expanded bag of words representation for object classification  

Science Conference Proceedings (OSTI)

Currently, the bag of visual words (BOW) representation has received wide applications in object categorization. However, the BOW representation ignores the dependency relationship among visual words, which could provide informative knowledge to understand ... Keywords: bag of words, object classification, query expansion, spatial correlation

Tinglin Liu; Jing Liu; Qinshan Liu; Hanqing Lu

2009-11-01T23:59:59.000Z

47

IEEE NANOSCIENCE and TECHNOLOGY BROWN BAG  

NLE Websites -- All DOE Office Websites (Extended Search)

PLEASE PLEASE JOIN US! NANOSCIENCE and TECHNOLOGY BROWN BAG Friday, 7 November 2008 Noon - 1 pm Columbia River Room (public access available) PNNL, ETB Building (Q Avenue, Richland, WA) speaker Dr. Meyya Meyyappan Chief Scientist for Exploration Technology, NASA Ames Research Center & IEEE Electron Devices Society Distinguished Lecturer presenting Nanotechnology in Chemical and Bio Sensor Systems Abstract: There are strong research programs in nanotechnology related to chemical sensors, electromechanical devices, actuators, biosensors, and other nanodevices in leading laboratories across the world which use nanomaterials and other molecularly-engineered approaches. In many cases, practical systems demand seamless integration of the nanodevice with higher order structures, for example, MEMS. Examples of this using carbon nanotube based chemical and biosensors

48

Fuzzy logic electric vehicle regenerative antiskid braking and traction control system  

DOE Patents (OSTI)

An regenerative antiskid braking and traction control system using fuzzy logic for an electric or hybrid vehicle having a regenerative braking system operatively connected to an electric traction motor, and a separate hydraulic braking system includes sensors for monitoring present vehicle parameters and a processor, responsive to the sensors, for calculating vehicle parameters defining the vehicle behavior not directly measurable by the sensor and determining if regenerative antiskid braking control, requiring hydraulic braking control, and requiring traction control are required. The processor then employs fuzzy logic based on the determined vehicle state and provides command signals to a motor controller to control operation of the electric traction motor and to the brake controller to control fluid pressure applied at each vehicle wheel to provide the appropriate regenerative braking control, hydraulic braking control, and traction control. 123 figs.

Cikanek, S.R.

1994-10-25T23:59:59.000Z

49

Fuzzy logic electric vehicle regenerative antiskid braking and traction control system  

DOE Patents (OSTI)

An regenerative antiskid braking and traction control system using fuzzy logic for an electric or hybrid vehicle having a regenerative braking system operatively connected to an electric traction motor, and a separate hydraulic braking system includes sensors for monitoring present vehicle parameters and a processor, responsive to the sensors, for calculating vehicle parameters defining the vehicle behavior not directly measurable by the sensor and determining if regenerative antiskid braking control, requiring hydraulic braking control, and requiring traction control are required. The processor then employs fuzzy logic based on the determined vehicle state and provides command signals to a motor controller to control operation of the electric traction motor and to the brake controller to control fluid pressure applied at each vehicle wheel to provide the appropriate regenerative braking control, hydraulic braking control, and traction control.

Cikanek, Susan R. (Wixom, MI)

1994-01-01T23:59:59.000Z

50

Regenerative braking device with rotationally mounted energy storage means  

DOE Patents (OSTI)

A regenerative braking device for an automotive vehicle includes an energy storage assembly (12) having a plurality of rubber rollers (26, 28) mounted for rotation between an input shaft (30) and an output shaft (32), clutches (50, 56) and brakes (52, 58) associated with each shaft, and a continuously variable transmission (22) connectable to a vehicle drivetrain and to the input and output shafts by the respective clutches. In a second embodiment the clutches and brakes are dispensed with and the variable ratio transmission is connected directly across the input and output shafts. In both embodiments the rubber rollers are torsionally stressed to accumulate energy from the vehicle when the input shaft rotates faster or relative to the output shaft and are torsionally relaxed to deliver energy to the vehicle when the output shaft rotates faster or relative to the input shaft.

Hoppie, Lyle O. (Birmingham, MI)

1982-03-16T23:59:59.000Z

51

Radiative corrections in fermion bags bound by Higgs boson exchange  

E-Print Network (OSTI)

Radiative corrections for several heavy fermions bound together via the Higgs boson exchange are studied. The fermion bags considered include 12, or fewer, fermions occupying the lowest S_{1/2} shell. It is shown that for `moderately heavy' fermions with masses 0.4< m c^2< 1 TeV the radiative corrections are small, 10^{-2}, and have an attractive nature. Therefore they do not put existence of the fermion bag in doubt. This proves that these fermion bags can exist in nature.

M. Yu. Kuchiev; V. V. Flambaum

2010-12-04T23:59:59.000Z

52

NOAA Predicts Mixed Bag of Drought, Flooding and Warm Weather...  

NLE Websites -- All DOE Office Websites (Extended Search)

NOAA Predicts Mixed Bag of Drought, Flooding and Warm Weather for Spring Print E-mail NOAA 2013 Spring Outlook Map Thursday, March 21, 2013 Featured by NOAA, a member of the U.S....

53

Transcriptional upregulation of BAG3 upon proteasome inhibition  

SciTech Connect

Proteasome inhibitors exhibit antitumoral activity against malignancies of different histology. Emerging evidence indicates that antiapoptotic factors may also accumulate as a consequence of exposure to these drugs, thus it seems plausible that activation of survival signaling cascades might compromise their antitumoral effects. Bcl-2-associated athanogene (BAG) family proteins are characterized by their property of interaction with a variety of partners involved in modulating the proliferation/death balance, including heat shock proteins (HSP), Bcl-2, Raf-1. In this report, we demonstrated that BAG3 is a novel antiapoptotic molecule induced by proteasome inhibitors in various cancer cells at the transcriptional level. Moreover, we demonstrated that BAG3 knockdown by siRNA sensitized cancer cells to MG132-induced apoptosis. Taken together, our results suggest that BAG3 induction might represents as an unwanted molecular consequence of utilizing proteasome inhibitors to combat tumors.

Wang Huaqin [Department of Biochemistry and Molecular Biology, China Medical University, Shenyang 110001 (China)], E-mail: wanghq_doctor@hotmail.com; Liu Haimei [Department of Anesthesiology, the 1st Affiliated Hospital, China Medical University, Shenyang 110001 (China); Zhang Haiyan [Department of Geriatrics, the 1st Affiliated Hospital, China Medical University, Shenyang 110001 (China); Guan Yifu [Department of Biochemistry and Molecular Biology, China Medical University, Shenyang 110001 (China); Du Zhenxian [Department of Endocrinology and Metabolism, the 1st Affiliated Hospital, China Medical University, Shenyang 110001 (China)

2008-01-11T23:59:59.000Z

54

Oxygen-Diffused Titanium as a Candidate Brake Rotor Material  

SciTech Connect

Titanium alloys are one of several candidate materials for the next generation of truck disk brake rotors. Despite their advantages of lightweight relative to cast iron and good strength and corrosion resistance, titanium alloys are unlikely to be satisfactory brake rotor materials unless their friction and wear behavior can be significantly improved. In this study, a surface engineering process oxygen diffusion was applied to titanium rotors and has shown very encouraging results. The oxygen diffused Ti-6Al-4V (OD-Ti) was tested on a sub-scale brake tester against a flat block of commercial brake lining material and benchmarked against several other Ti-based materials, including untreated Ti-6Al-4V, ceramic particle-reinforced Ti composites (MMCs), and a thermal-spray-coated Ti alloy. With respect to friction, the OD-Ti outperformed all other candidate materials under the imposed test conditions with the friction coefficient remaining within a desirable range of 0.35-0.50, even under the harshest conditions when the disk surface temperature reached nearly 600 ?C. In addition, the OD-Ti showed significantly improved wear-resistance over the non-treated one and was even better than the Ti-based composite materials.

Qu, Jun [ORNL; Blau, Peter Julian [ORNL; Jolly, Brian C [ORNL

2009-01-01T23:59:59.000Z

55

The use of filtered bags to increase waste payload capacity  

DOE Green Energy (OSTI)

For the past few years, the Department of Energy has favored the direct disposal of low plutonium content residue materials from Rocky Flats rather than engage in expensive and time consuming plutonium recovery operations. One impediment to direct disposal has been the wattage limit imposed by the Waste Isolation Pilot Plant on hydrogenous materials such as combustibles and sludges. The issue of concern is the radiolytic generation and accumulation of hydrogen and other explosive gases in waste containers. The wattage limits that existed through 1996 restricted the amount of plutonium bearing hydrogenous materials that could be packaged in a WIPP bound waste drum to only a fraction of the capacity of a drum. Typically, only about one kilogram of combustible residue could be packaged in a waste drum before the wattage limit was exceeded resulting in an excessively large number of drums to be procured, stored, shipped, and interred. The Rocky Flats Environmental Technology Site has initiated the use of filtered plastic bags (called bag-out bags) used to remove transuranic waste materials from glove box lines. The bags contain small, disk like HEPA filters which are effective in containing radioactively contaminated particulate material but allow for the diffusion of hydrogen gas. Used in conjunction with filtered 55 gallon drums, filtered bag-out bags were pursued as a means to increase the allowable wattage limits for selected residue materials. In February 1997, the Nuclear Regulatory Commission approved the use of filtered bag-out bags for transuranic waste materials destined for WIPP. The concomitant increase in wattage limits now allows for approximately four times the payload per waste drum for wattage limited materials.

Dustin, D.F.; Thorp, D.T. [Safe Sites of Colorado, Golden, CO (United States); Rivera, M.A. [Los Alamos Technical Associates, Albuquerque, NM (United States)

1998-03-03T23:59:59.000Z

56

Determination of H{sub 2} Diffusion Rates through Various Closures on TRU Waste Bag-Out Bags  

DOE Green Energy (OSTI)

The amount of H{sub 2} diffusion through twist and tape (horse-tail), wire tie, plastic tie, and heat sealed closures on transuranic (TRU) waste bag-out bags has been determined. H{sub 2} diffusion through wire and plastic tie closures on TRU waste bag-out bags has not been previously characterized and, as such, TRU waste drums containing bags with these closures cannot be certified and/or shipped to the Waste Isolation Pilot Plant (WIPP). Since wire ties have been used at Los Alamos National Laboratory (LANL) from 1980 to 1991 and the plastic ties from 1991 to the present, there are currently thousands of waste drums that cannot be shipped to the WIPP site. Repackaging the waste would be prohibitively expensive. Diffusion experiments performed on the above mentioned closures show that the diffusion rates of plastic tie and horse-tail closures are greater than the accepted value presented in the TRU-PACT 11 Safety Analysis Report (SAR). Diffusion rates for wire tie closures are not statistically different from the SAR value. Thus, drums containing bags with these closures can now potentially be certified which would allow for their consequent shipment to WIPP.

Phillip D. Noll, Jr.; E. Larry Callis; Kirsten M. Norman

1999-06-01T23:59:59.000Z

57

Heavy and Overweight Vehicle Brake Testing: Five-Axle Combination Tractor-Flatbed Final Report  

Science Conference Proceedings (OSTI)

The Federal Motor Carrier Safety Administration, in coordination with the Federal Highway Administration, sponsored the Heavy and Overweight Vehicle Brake Testing (HOVBT) program in order to provide information about the effect of gross vehicle weight (GVW) on braking performance. Because the Federal Motor Carrier Safety Regulations limit the number of braking system defects that may exist for a vehicle to be allowed to operate on the roadways, the examination of the effect of brake defects on brake performance for increased loads is also relevant. The HOVBT program seeks to provide relevant information to policy makers responsible for establishing load limits, beginning with providing test data for a combination tractor/trailer. This testing was conducted on a five-axle combination vehicle with tractor brakes meeting the Reduced Stopping Distance requirement rulemaking. This report provides a summary of the testing activities, the results of various analyses of the data, and recommendations for future research. Following a complete brake rebuild, instrumentation, and brake burnish, stopping tests were performed from 20 and 40 mph with various brake application pressures (15 psi, 25 psi, 35 psi, 45 psi, 55 psi, and full system pressure). These tests were conducted for various brake conditions at the following GVWs: 60,000, 80,000, 91,000, 97,000, 106,000, and 116,000 lb. The 80,000-lb GVWs included both balanced and unbalanced loads. The condition of the braking system was also varied. To introduce these defects, brakes (none, forward drive axle, or rear trailer axle) were made inoperative. In addition to the stopping tests, performance-based brake tests were conducted for the various loading and brake conditions. Analysis of the stopping test data showed the stopping distance to increase with load (as expected) and also showed that more braking force was generated by the drive axle brakes than the trailer axle brakes. The constant-pressure stopping test data revealed a linear relationship between brake application pressure and was used to develop an algorithm to normalize stopping data for weight and initial speed.

Lascurain, Mary Beth [ORNL] ORNL; Capps, Gary J [ORNL] ORNL; Franzese, Oscar [ORNL] ORNL

2013-10-01T23:59:59.000Z

58

Energy Efficiency in Heavy Vehicle Tires, Drivetrains, and Braking Systems  

DOE Green Energy (OSTI)

This document was prepared to support the primary goals of the Department of Energy, Office of Heavy Vehicle Technologies. These were recently stated as follows: ''Develop by 2004 the enabling technologies for a class 7-8 truck with a fuel efficiency of 10 mpg (at 65 mph) which will meet prevailing emission standards. For Class 3-6 trucks operating on an urban driving cycle, develop by 2004 commercially viable vehicles that achieve at least double the fuel economy of comparable current vehicles (1999), and as a research goal, reduce criteria pollutants to 30% below EPA standards. Develop by 2004 the diesel engine enabling technologies to support large-scale industry dieselization of Class 1 and 2 trucks, achieving a 35 % fuel efficiency improvement over comparable gasoline-fueled trucks, while meeting applicable emissions standards.'' The enabling technologies for improving the fuel efficiency of trucks, include not only engine technologies but also technologies involved with lowering the rolling resistance of tires, reducing vehicle aerodynamic drag, improving thermal management, and reducing parasitic frictional losses in drive train components. Opportunities also exist for making better use of the energy that might ordinarily be dissipated during vehicle braking. Braking systems must be included in this evaluation since safety in truck operations is vital, and braking requirements are greater for vehicles having lowered resistance to rolling. The Office of Heavy Vehicle Technologies has initiated a program to improve the aerodynamics of heavy vehicles through wind tunnel testing, computational modeling, and on-road evaluations. That activity is described in a separate multi-year plan; therefore, emphasis in this document will be on tires, drive trains, and braking systems. Recent, dramatic fluctuations in diesel fuel prices have emphasized the importance of effecting savings in truck fuel economy by implementing new component designs and materials.

Peter J. Blau

2000-04-26T23:59:59.000Z

59

Brake rotor design and comparison using finite element analysis : an investigation in topology optimization.  

E-Print Network (OSTI)

??Disc brake technology used for mountain bikes, and mountain bike technology in general, has improved significantly as the sport of mountain biking has evolved. Disc (more)

Domond, Kenneth

2010-01-01T23:59:59.000Z

60

Numerical Simulation of Brake Discs of CRH3 High-Speed Trains ...  

Science Conference Proceedings (OSTI)

... the research object?the course of emergency brake was simulated by ANSYS. .... Energy X-Ray Diffraction Microscopy Studies of Bulk Polycrystal Responses.

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


61

Geek-Up[08.20.10] -- Turning Trash Bags into Battery Anodes and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Other Agencies You are here Home Geek-Up08.20.10 -- Turning Trash Bags into Battery Anodes and Researching the Gut Microbiome Geek-Up08.20.10 -- Turning Trash Bags...

62

Randomized locality sensitive vocabularies for bag-of-features model  

Science Conference Proceedings (OSTI)

Visual vocabulary construction is an integral part of the popular Bag-of-Features (BOF) model. When visual data scale up (in terms of the dimensionality of features or/and the number of samples), most existing algorithms (e.g. k-means) become unfavorable ...

Yadong Mu; Ju Sun; Tony X. Han; Loong-Fah Cheong; Shuicheng Yan

2010-09-01T23:59:59.000Z

63

BIO-BAG Type Cfj Environmental Chamber DESCRIPTION  

E-Print Network (OSTI)

BIO-BAG Type Cfj is a disposable, individual environmental chamber and a gas generator, consisting of one tablet of potassium borohydride-sodium bicarbonate and an ampule of hydrochloric acid, which when activated in the sealed BIO-BAG chamber provides a microaerophilic atmosphere. INTENDED USE BIO-BAG Type Cfj is designed to provide a microaerophilic environment suitable for the isolation of Campylobacter jejuni, formerly known as C. fetus subsp. jejuni (Cfj), from clinical specimens or subcultures from selective media. When used as directed, BIO-BAG Type Cfj will provide an atmosphere that has been shown to provide optimum growth of C. jejuni. 1,2 SUMMARY AND EXPLANATION Campylobacter jejuni has been recognized as a common enteric pathogen. 2,4,7,8 This organism is a true microaerophile and a capnophilic atmosphere has been shown to enhance growth. 5 Use of a selective medium containing 5 % sheep blood and a combination of antimicrobial agents and incubation at 42C provides conditions favorable for the selective isolation of C. jejuni from intestinal flora. 3,6 Under ideal conditions, characteristic colonies may be observed in 24 to 48 h, 1,2,5 Each BIO-BAG Type Cfj system allows cultures to be set up and observed for growth individually, so that appropriate atmospheric conditions are not interrupted. Exposure to atmospheric oxygen may interfere with the growth of more oxygen-sensitive strains. 5 PRINCIPLE OF THE PROCEDURE A microaerophilic-capnophilic atmosphere is provided in each sealed BIO-BAG Type Cfj system. A self-contained generator consists of an ampule of a weak hydrochloric acid solution and a gas generator tablet. When the ampule is crushed, the tablet is then activated. A portion of atmospheric oxygen in the chamber is utilized in the reaction. The resulting atmosphere is conducive to the isolation and cultivation of C. jejuni. 1,2 Each BIO-BAG Type Cfj system is disposable and designed to be used only once.

unknown authors

1999-01-01T23:59:59.000Z

64

Improving scalability of Bag-of-Tasks applications running on master-slave platforms  

Science Conference Proceedings (OSTI)

Bag-of-Tasks applications are parallel applications composed of independent tasks. Examples of Bag-of-Tasks (BoT) applications include Monte Carlo simulations, massive searches (such as key breaking), image manipulation applications and data mining algorithms. ... Keywords: Bag-of-Tasks applications, Master-slave platforms, Scalability analysis

Fabr?cio A. B. da Silva; Hermes Senger

2009-02-01T23:59:59.000Z

65

Tachyon cosmology, supernovae data, and the big brake singularity  

SciTech Connect

We compare the existing observational data on type Ia supernovae with the evolutions of the Universe predicted by a one-parameter family of tachyon models which we have introduced recently [Phys. Rev. D 69, 123512 (2004)]. Among the set of the trajectories of the model which are compatible with the data there is a consistent subset for which the Universe ends up in a new type of soft cosmological singularity dubbed big brake. This opens up yet another scenario for the future history of the Universe besides the one predicted by the standard {lambda}CDM model.

Keresztes, Z.; Gergely, L. A.; Gorini, V.; Moschella, U.; Kamenshchik, A. Yu. [Department of Theoretical Physics, University of Szeged, Tisza Lajos krt 84-86, Szeged 6720 (Hungary); Department of Experimental Physics, University of Szeged, Dom Ter 9, Szeged 6720 (Hungary); Department of Theoretical Physics, University of Szeged, Tisza Lajos krt 84-86, Szeged 6720 (Hungary); Department of Experimental Physics, University of Szeged, Dom Ter 9, Szeged 6720 (Hungary); Department of Applied Science, London South Bank University, 103 Borough Road, London SE1 OAA (United Kingdom); Dipartimento di Scienze Fisiche e Mathematiche, Universita dell'Insubria, Via Valleggio 11, 22100 Como (Italy); INFN, sezione di Milano, Via Celoria 16, 20133 Milano (Italy); Dipartimento di Fisica and INFN, via Irnerio 46, 40126 Bologna (Italy); L. D. Landau Institute for Theoretical Physics, Russian Academy of Sciences, Kosygin street 2, 119334 Moscow (Russian Federation)

2009-04-15T23:59:59.000Z

66

Dual-channel Haptic Synthesis of Viscoelastic Tissue Properties using Programmable Eddy Current Brakes  

Science Conference Proceedings (OSTI)

We describe a novel method for haptic synthesis of viscoelastic responses which employs a dual-channel haptic interface. It has motors that generate torque independently of velocity and brakes that generate viscous torque independently of position. ... Keywords: eddy current brakes, haptic simulation, viscoelastic simulation

Andrew H. C. Gosline; Vincent Hayward

2009-10-01T23:59:59.000Z

67

Simulation of PSO Fuzzy Control Stratety for Regenerative Braking of HEV  

Science Conference Proceedings (OSTI)

Based on particle swarm optimization algorithm, a new fuzzy controller was constructed and a fuzzy control strategy of regenerative braking for HEV was proposed. A model of a parallel hybrid electric vehicle was built. The performance of the default ... Keywords: hybrid electric vehicle, fuzzy control, regenerative braking, particle swarm optimization

Wang Chun; Tang Lan

2012-04-01T23:59:59.000Z

68

Operation Pattern Recognition and Control for Super Capacitor Braking Energy Regeneration System of Micro EV  

Science Conference Proceedings (OSTI)

Super capacitor has some advantages of high charge-discharge rate, long life, simple structure and reliable performance, and it is especially suitable as braking energy renewable energy storage device for electric vehicle and hybrid electric vehicle. ... Keywords: Super capacitor, braking energy regeneration, micro EV, pattern recognition and control

Jinyu Qu; Liyan Liang; Zhongyu Yang

2009-12-01T23:59:59.000Z

69

Microsoft PowerPoint - Real-Time Dynamic Brake Assessment poster.ppt [Compatibility Mode]  

NLE Websites -- All DOE Office Websites (Extended Search)

Dynamic Brake Assessment Dynamic Brake Assessment Purpose Conduct a proof-of-concept test to examine the feasibility of developing an on-board system to assess a vehicle's ability to stop based on typical low-pressure in-service braking events. Partnerships H.T. Hackney Company MGM Brakes Overview Funded through the Federal Motor Carrier Safety Administration's Vehicle and Roadside Operations Division Concept stemming from on the Department of Energy's Medium Truck Duty Cycle research as well as previous research conducted for the National Highway Transportation Safety Administration. Signals to be collected Real-time brake application pressure Vehicle speed and acceleration GPS location and grade information Vehicle weight (current load) Engine parameters such as RPM and torque To be conducted October 2010 -

70

Wind turbine trailing-edge aerodynamic brake design  

DOE Green Energy (OSTI)

This report describes the design of a centrifugally actuated aerodynamic-overspeed device for a horizontal-axis wind turbine. The device will meet the following criteria; (1) It will be effective for airfoil angles of attack 0{degrees} to 45{degrees}. (2) It will be stowed inside the blade profile prior to deployment. (3) It will be capable of offsetting the positive torque produced by the overall blade. (4) Hinge moments will be minimized to lower actuator loads and cost. (5) It will be evaluated as a potential power modulating active rotor-control system. A literature review of aerodynamic braking devices was conducted. Information from the literature review was used to conceptualize the most effective devices for subsequent testing and design. Wind-tunnel test data for several braking devices are presented in this report. Using the data for the most promising configuration, a preliminary design was developed for a MICON 65/13 wind turbine with Phoenix 7.9-m rotor blades.

Quandt, G.

1996-01-01T23:59:59.000Z

71

Transport characteristics across drum filter vents and polymer bags  

DOE Green Energy (OSTI)

The rate at which hydrogen (H {sub 2}) or a volatile organic compound (VOC) exits a layer of confinement in a vented waste drum is proportional to the concentration difference across the layer. The proportionality constant is the gas transport characteristic. A series of transport experiments were conducted to determine H{sub 2} and VOC transport characteristics across different drum filter vents and polymer bags. This report reviews the methods and results of past investigators in defining transport characteristics across filter vents and polymer bags, describes the apparatus and procedures used in these experiments, compares the reported and estimated transport characteristics with earlier results, and discusses the impact of changing the transport characteristic values used in model calculations.

Liekhus, K.J.

1994-08-01T23:59:59.000Z

72

Nonlinear Control Synthesis for a Self-energizing Electro-Hydraulic Brake  

E-Print Network (OSTI)

Nonlinear control algorithm for a self-energizing electro-hydraulic brake is analytically designed. The desired closed-loop system behavior is reached via a synthesized nonlinear controller.

Starykh, Alexey

2010-01-01T23:59:59.000Z

73

A METHOD FOR ESTIMATING THE CONFIDENCE IN THE IDENTIFICATION OF NUCLEAR TRANSIENTS BY A BAGGED  

E-Print Network (OSTI)

in the feedwater system of a nuclear Boiling Water Reactor (BWR). The obtained results indicate that the bagging-fuzzy system for fault detection and isolation in nuclear reactors," Advanced Engineering Informatics, 19 (1A METHOD FOR ESTIMATING THE CONFIDENCE IN THE IDENTIFICATION OF NUCLEAR TRANSIENTS BY A BAGGED

74

Bag of spatio-visual words for context inference in scene classification  

Science Conference Proceedings (OSTI)

In the ''bag of visual words (BoVW)'' representation each image is represented by an unordered set of visual words. In this paper, a novel approach to encode ordered spatial configurations of visual words in order to add context in the representation ... Keywords: Bag of spatio-visual words, Contextual descriptors, Ensembles' learning, High dimensional features' clustering, Scene classification, Spatial co-occurrence

A. Bolovinou; I. Pratikakis; S. Perantonis

2013-03-01T23:59:59.000Z

75

Edge States: Topological Insulators, Superconductors and QCD Chiral Bags  

E-Print Network (OSTI)

The dynamics of the magnetic field in a superconducting phase is described by an effective massive bosonic field theory. If the superconductor is confined in a domain M with boundary \\partial M, the boundary conditions of the electromagnetic fields are predetermined by physics. They are time-reversal and also parity invariant for adapted geometry. They lead to edge excitations while in comparison, the bulk energies have a large gap. A similar phenomenon occurs for topological insulators where appropriate boundary conditions for the Dirac Hamiltonian also lead to similar edge states and an 'incompressible bulk'. They give spin-momentum locking as well. In addition time-reversal and parity invariance emerge for adapted geometry. Similar edge states appear in QCD bag models with chiral boundary conditions.

M. Asorey; A. P. Balachandran; J. M. Perez-Pardo

2013-08-26T23:59:59.000Z

76

Control of a dynamic brake to reduce turbine-generator shaft transient torques  

SciTech Connect

A resistive, thyristor-controlled brake is used to damp transient torques in large thermo-electric generators supplying series-compensated transmission lines. Emphasis is placed on developing a suitable control algorithm and testing the algorithm through a wide variety of different operating configurations. Discrete-level Generalized Predictive Control is examined as one possible approach to optimal control of the brake. Some problems with implementation of GPC on the system are discussed. Prony analysis is used to identify system transfer functions which are then related to control design considerations and robustness properties.

Donnelly, M.K.; Smith, J.R.; Johnson, R.M. (Montana State Univ., Bozeman, MT (United States)); Hauer, J.F. (Bonneville Power Administration, Kalispell, MT (United States)); Brush, R.W. (Montana Power Co., Butte, MT (United States)); Adapa, R. (Electric Power Research Inst., Palo Alto, CA (United States))

1993-02-01T23:59:59.000Z

77

Geek-Up[08.20.10] -- Turning Trash Bags into Battery Anodes and Researching  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

8.20.10] -- Turning Trash Bags into Battery Anodes and 8.20.10] -- Turning Trash Bags into Battery Anodes and Researching the Gut Microbiome Geek-Up[08.20.10] -- Turning Trash Bags into Battery Anodes and Researching the Gut Microbiome August 20, 2010 - 5:18pm Addthis Elizabeth Meckes Elizabeth Meckes Director of User Experience & Digital Technologies, Office of Public Affairs What are the key facts? An Argonne Scholar has figured out a way to convert grocery bags into carbon nanotubes that can be used as components for lithium-ion batteries. We have about three pounds of bacteria living in our gut -- most of which is helpful for our immune system development and metabolism. Scientists at Ames Laboratory are making batteries that are "greener" and more cost-efficient by using rare earth elements -- neodymium

78

Quark compound Bag model for NN scattering up to 1 GeV  

SciTech Connect

A Quark Compound Bag model has been constructed to describe NN s-wave scattering up to 1 GeV. The model contains a vertex interaction H/sub D/leftrightarrow/NN/ for describing the excitation of a confined six-quark Bag state, and a meson-exchange interaction obtained from modifying the phenomenological core of the Paris potential. Explicit formalisms and numerical results are presented to reveal the role of the Bag excitation mechanism in determining the relative wave function, P- and S-matrix of NN scattering. We explore the merit as well as the shortcoming of the Quark Compound Bag model developed by the ITEP group. It is shown that the parameters of the vertex interaction H/sub D/leftrightarrow/NN/ can be more rigorously determined from the data if the notation of the Chiral/Cloudy Bag model is used to allow the presence of the background meson-exchange interaction inside Bag excitation region. The application of the model in the study of quark degrees of freedom in nuclei is discussed. 41 refs., 6 figs., 3 tabs.

Fasano, C.; Lee, T.S.H.

1987-01-01T23:59:59.000Z

79

Use of an auditory signal in a rear-end collision warning system: effects on braking force and reaction time  

E-Print Network (OSTI)

This simulator experiment is a preliminary study examining the effects of different auditory signals on braking force and reaction time in a rear-end collision warning system. A driving simulator was built in which subjects operated a computer driving game. Superimposed on the game screen was the image of a car which appeared to the driver to be ahead of him/her. The image enlarged in size, appearing to be a car applying its brakes. The participant was instructed to react as he would in a real driving situation by applying his/her brakes. Closing velocities of 10 miles per hour and 30 miles per hour were used. Braking times and forces were measured for four different warning sounds: 1) no warning; 2) a pulsed warning sound that increased in repetition rate; 3) a sound that increased in frequency; and, 4) a sound that increased in intensity. Results suggested that an auditory warning signal would decrease reaction time and increase maximum braking force applied. The sound that increased in frequency and the sound that increased in intensity provided the greatest savings in reaction time, approximately one quarter second, when compared to the no warning condition. The pulsed warning sound provided the greatest increase in braking force. Participants preferred the pulsed sound over the other warning sounds. Further research must be done to determine if the warning sounds decrease the reaction time enough to cause a significant reduction in accidents.

Hopkins, Jennifer Susan

1995-01-01T23:59:59.000Z

80

Collapse and Fragmentation of Molecular Cloud Cores. X. Magnetic Braking of Prolate and Oblate Cores  

E-Print Network (OSTI)

The collapse and fragmentation of initially prolate and oblate, magnetic molecular clouds is calculated in three dimensions with a gravitational, radiative hydrodynamics code. The code includes magnetic field effects in an approximate manner: magnetic pressure, tension, braking, and ambipolar diffusion are all modelled. The parameters varied for both the initially prolate and oblate clouds are the initial degree of central concentration of the radial density profile, the initial angular velocity, and the efficiency of magnetic braking (represented by a factor $f_{mb} = 10^{-4}$ or $10^{-3}$). The oblate cores all collapse to form rings that might be susceptible to fragmentation into multiple systems. The outcome of the collapse of the prolate cores depends strongly on the initial density profile. Prolate cores with central densities 20 times higher than their boundary densities collapse and fragment into binary or quadruple systems, whereas cores with central densities 100 times higher collapse to form single...

Boss, Alan P

2009-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


81

How Many CVs are Crossing the Period Gap? A Test for the Disruption of Magnetic Braking  

E-Print Network (OSTI)

We apply population synthesis techniques to calculate the present day number of two types of white dwarf-main sequence star (WDMS) binaries within the cataclysmic variable period gap. The first are post-common envelope binaries with secondary stars that have masses between 0.17 and 0.36 Msun (gPCEBs), such that they will commence mass transfer within the period gap. The second type are systems that were CVs at some point in their past, but detached once they evolved down in orbital period to ~3 h as a consequence of disrupted magnetic braking, and are crossing the period gap via gravitational radiation (dCVs). Full population synthesis calculations are performed where we assume either constant, global values of the common envelope ejection efficiency, or consider the ejection efficiency as a function of secondary mass. Several forms of magnetic braking are also considered. We predict an excess of dCVs over gPCEBs within the period gap of ~4 to ~13 assuming an ejection efficiency between 0.1 and 0.6, and a flat initial mass ratio distribution. This excess is revealed as a prominent peak at the location of the period gap in the orbital period distribution of the combined gPCEB and dCV population. We suggest that if such a feature is observed in the orbital period distribution of an observed sample of short orbital period WDMS binaries, this would strongly corroborate the disruption of magnetic braking.

P. J. Davis; U. Kolb; B. Willems; B. T. Gnsicke

2008-05-30T23:59:59.000Z

82

Variations in gear fatigue life for different wind turbine braking strategies  

SciTech Connect

A large number of gearbox failures have occurred in the wind industry in a relatively short period, many because service loads were underestimated. High-torque transients that occur during starting and stopping are difficult to predict and may be overlooked in specifying gearbox design. Although these events comprise a small portion of total load cycles, they can be the most damaging. The severity of these loads varies dramatically with the specific configuration of the wind turbine. The large number of failures in Danish-designed Micon 65 wind turbines prompted this investigation. The high-speed and low-speed shaft torques were measured on a two-stage helical gearbox of a single Micon 65 turbine. Transient events and normal running loads were combined statistically to obtain a typical annual load spectrum. The pitting and bending fatigue lives of the gear teeth were calculated by using Miner's rule for four different high-speed shaft brake configurations. Each breaking scenario was run for both a high- and a low-turbulence normal operating load spectrum. The analysis showed increases in gear life by up to a factor of 25 when the standard high-speed shaft brake is replaced with a dynamic brake or modified with a damper. 9 refs., 9 figs., 3 tabs.

McNiff, B.P. (Second Wind, Inc., Somerville, MA (USA)); Musial, W.D. (Solar Energy Research Inst., Golden, CO (USA)); Errichello, R. (GEARTECH, Albany, CA (USA))

1991-06-01T23:59:59.000Z

83

Variations in gear fatigue life for different wind turbine braking strategies  

DOE Green Energy (OSTI)

A large number of gearbox failures have occurred in the wind industry in a relatively short period, many because service loads were underestimated. High-torque transients that occur during starting and stopping are difficult to predict and may be overlooked in specifying gearbox design. Although these events comprise a small portion of total load cycles, they can be the most damaging. The severity of these loads varies dramatically with the specific configuration of the wind turbine. The large number of failures in Danish-designed Micon 65 wind turbines prompted this investigation. The high-speed and low-speed shaft torques were measured on a two-stage helical gearbox of a single Micon 65 turbine. Transient events and normal running loads were combined statistically to obtain a typical annual load spectrum. The pitting and bending fatigue lives of the gear teeth were calculated by using Miner's rule for four different high-speed shaft brake configurations. Each breaking scenario was run for both a high- and a low-turbulence normal operating load spectrum. The analysis showed increases in gear life by up to a factor of 25 when the standard high-speed shaft brake is replaced with a dynamic brake or modified with a damper. 9 refs., 9 figs., 3 tabs.

McNiff, B.P. (Second Wind, Inc., Somerville, MA (USA)); Musial, W.D. (Solar Energy Research Inst., Golden, CO (USA)); Errichello, R. (GEARTECH, Albany, CA (USA))

1991-06-01T23:59:59.000Z

84

Comparing the usability of grid-bag and constraint-based layouts  

Science Conference Proceedings (OSTI)

While the usability of GUI design methods has been studied in general, the usability of layout specification methods is largely unexplored. In this paper we provide an empirical comparison of two popular GUI layout models, grid-bag layout and constraint-based ... Keywords: API, empiric evaluation, layout, usability

Clemens Zeidler; Johannes Mller; Christof Lutteroth; Gerald Weber

2012-11-01T23:59:59.000Z

85

A comparison of three voting methods for bagging with the MLEM2 algorithm  

Science Conference Proceedings (OSTI)

This paper presents results of experiments on some data sets using bagging on the MLEM2 rule induction algorithm. Three different methods of ensemble voting, based on support (a non-democratic voting in which ensembles vote with their strengths), strength ...

Clinton Cohagan; Jerzy W. Grzymala-Busse; Zdzislaw S. Hippe

2010-09-01T23:59:59.000Z

86

Solar tracker motor having a fixed caliper and a translating caliper each with an electromagnetic brake system  

Science Conference Proceedings (OSTI)

Concepts and technologies described herein provide for an accurate and cost-effective method for rotating a solar array disk for tracking the movement of the sun. According to various aspects, a motor includes a fixed caliper and a translating caliper positioned adjacent to one another. Electromagnetically controlled brakes on the translating caliper grip the solar array disk while adjacent, but spaced apart, electromagnets on the fixed caliper and the translating caliper are energized to create an attractive force that pulls the translating caliper with the solar array disk toward the fixed caliper. After reaching the fixed caliper, brakes on the fixed caliper are engaged with the disk, brakes on the translating caliper are released from the disk, and the translating caliper is pushed back to the starting location where the process repeats until the desired rotation is completed.

Rau, Scott James

2013-01-29T23:59:59.000Z

87

The effects of oxygen-enriched intake air on FFV exhaust emissions using M85  

Science Conference Proceedings (OSTI)

This paper presents results of emission tests of a flexible fuel vehicle (FFV) powered by an SI engine, fueled by M85 (methanol), and supplied with oxygen-enriched intake air containing 21, 23, and 25 vol% O2. Engine-out total hydrocarbons (THCs) and unburned methanol were considerably reduced in the entire FTP cycle when the O2 content of the intake air was either 23 or 25%. However, CO emissions did not vary much, and NOx emissions were higher. HCHO emissions were reduced by 53% in bag 1, 84% in bag 2, and 59% in bag 3 of the FTP cycle with 25% oxygen-enriched intake air. During cold-phase FTP,reductions of 42% in THCs, 40% in unburned methanol, 60% in nonmethane hydrocarbons, and 45% in nonmethane organic gases (NMOGs) were observed with 25% enriched air; NO{sub x} emissions increased by 78%. Converter-out emissions were also reduced with enriched air but to a lesser degree. FFVs operating on M85 that use 25% enriched air during only the initial 127 s of cold-phase FTP or that use 23 or 25% enriched air during only cold-phase FTP can meet the reactivity-adjusted NMOG, CO, NO{sub x}, and HCHO emission standards of the transitional low-emission vehicle.

Poola, R.B.; Sekar, R.; Ng, H.K. [Argonne National Lab., IL (United States); Baudino, J.H. [Autoresearch Labs., Inc., Chicago, IL (United States); Colucci, C.P. [National Renewable Energy Lab., Golden, CO (United States)

1996-05-01T23:59:59.000Z

88

Developing a bag monitor setpoint for release of green is clean waste  

SciTech Connect

The Connecticut Yankee Atomic Power Company Haddam Neck Plant (CY) has established a Green is Clean program in which uncontaminated trash generated inside the Radiological control Area (RCA) is placed in green receptacles. This article describes the development of a bag monitor alarm setpoint for unconditional release of Green is Clean material from the RCA. The setpoint was based on detecting radiation that could be the to be statistically different from background with a high degree of confidence. Radioactivity in waste-type material, which had never been in the RCA, was quantified and accounted for in the setpoint as material background. The experience is that the bag monitor (along with a waste sorting ale for the location of individual contaminated items) improves detection capabilities while reducing the amount of Green is Clean waste which is treated as rad waste.

McGrath, R.N. (Connecticut Yankee Atomic Power Co., Haddam, CT (United States))

1989-12-01T23:59:59.000Z

89

Can the standard model CP violation near the W bags explain the cosmological baryonic asymmetry?  

Science Conference Proceedings (OSTI)

In the scenario of cold electroweak baryogenesis, oscillations of the Higgs field lead to metastable domains of unbroken phase where the Higgs field nearly vanishes. Those domains have also been identified with the W-t-t bags, a nontopological solitons made of large number ({approx}1000) of gauge quanta and heavy (top and antitop) quarks. As real-time numerical studies had shown, sphalerons (topological transition events violating the baryon number) occur only inside those bags. In this work we estimate the amount of CP violation in this scenario coming from the standard model, via the Cabibbo-Kobayashi-Maskawa (CKM) quark mixing matrix, resulting in top-minus-antitop difference of the population in the bags. Since these tops/antitops are recycled by sphalerons, this population difference leads directly to the baryonic asymmetry of the Universe. We look at the effect appearing in the 4th order in weak W diagrams describing interference of different quark flavor contributions. We found that there are multiple cancellations of diagrams and clearly sign-definite effect appears only in the 6th-order expansion over flavor-dependent phases. We then estimate contributions to these diagrams in which weak interaction occurs (i) inside, (ii) near and (iii) far from the W-t-t b-bags, optimizing the contributions in each of them. We conclude that the second (near) scenario is the dominant one, producing CP violation of the order of 10{sup -10}, in our crude estimates. Together with the baryon violation rate of about 10{sup -2}, previously demonstrated for this scenario, it puts the resulting asymmetry close to what is needed to explain the observed baryonic asymmetry in the Universe. Our answer also has a definite sign, which apparently seems to be the correct one.

Burnier, Yannis; Shuryak, Edward [Department of Physics, State University of New York, Stony Brook, New York 11794 (United States)

2011-10-01T23:59:59.000Z

90

Amplitudes of radiative corrections in fermion bags bound by Higgs boson exchange  

E-Print Network (OSTI)

Properties of amplitudes that describe radiative corrections in a bag of heavy fermions bound by the Higgs boson exchange are studied. Classes of amplitudes, in which the large fermion mass is canceled out and hence produces no enhancement for the radiative corrections are found. For fermions with masses in the region 4001000 Gev, the processes described by diagrams with closed fermion loops are also mass-independent.

M. Yu. Kuchiev

2010-12-04T23:59:59.000Z

91

Evaluation of Microwave Steam Bags for the Decontamination of Filtering Facepiece Respirators  

E-Print Network (OSTI)

Reusing filtering facepiece respirators (FFRs) has been suggested as a strategy to conserve available supplies for home and healthcare environments during an influenza pandemic. For reuse to be possible, used FFRs must be decontaminated before redonning to reduce the risk of virus transmission; however, there are no approved methods for FFR decontamination. An effective method must reduce the microbial threat, maintain the function of the FFR, and present no residual chemical hazard. The method should be readily available, inexpensive and easily implemented by healthcare workers and the general public. Many of the general decontamination protocols used in healthcare and home settings are unable to address all of the desired qualities of an efficient FFR decontamination protocol. The goal of this study is to evaluate the use of two commercially available steam bags, marketed to the public for disinfecting infant feeding equipment, for FFR decontamination. The FFRs were decontaminated with microwave generated steam following the manufacturers instructions then evaluated for water absorption and filtration efficiency for up to three steam exposures. Water absorption of the FFR was found to be model specific as FFRs constructed with hydrophilic materials absorbed more water. The steam had little effect on FFR performance as filtration efficiency of the treated FFRs remained above 95%. The decontamination efficacy of the steam bag was assessed using bacteriophage MS2 as a surrogate for a pathogenic virus. The tested steam bags were found to be 99.9 % effective for inactivating MS2 on FFRs; however, more research is required to

Edward M. Fisher; Jessica L. Williams; Ronald E. Shaffer

2011-01-01T23:59:59.000Z

92

On The Use of Eddy Current Brakes as Tunable, Fast Turn-On Viscous Dampers For Haptic Rendering  

E-Print Network (OSTI)

based on eddy current brakes because they are inexpensive, friction- e-mail: andrewg@cim.mcgill.ca e-mail: champ@cim.mcgill.ca e-mail: hayward@cim.mcgill.ca free, capable of fast turn-on time, and linear

Hayward, Vincent

93

CityCarControl : an electric vehicle drive-by-wire solution for distributed steering, braking and throttle control  

E-Print Network (OSTI)

In this paper, we propose CityCarControl, a system to manage the steering, braking, and throttle of a new class of intra-city electric vehicles. These vehicles have a focus on extreme light-weight and a small parking ...

Brown, Thomas B., M. Eng. Massachusetts Institute of Technology

2010-01-01T23:59:59.000Z

94

Injection Timing Effects on Brake Fuel Conversion Efficiency and Engine System's Respones  

E-Print Network (OSTI)

Societal concerns on combustion-based fuel consumption are ever-increasing. With respect to internal combustion engines, this translates to a need to increase brake fuel conversion efficiency (BFCE). Diesel engines are a relatively efficient internal combustion engine to consider for numerous applications, but associated actions to mitigate certain exhaust emissions have generally deteriorated engine efficiency. Conventionally, diesel engine emission control has centered on in-cylinder techniques. Although these continue to hold promise, the industry trend is presently favoring the use of after-treatment devices which create new opportunities to improve the diesel engine's brake fuel conversion efficiency. This study focuses on injection timing effects on the combustion processes, engine efficiency, and the engine system's responses. The engine in the study is a medium duty diesel engine (capable of meeting US EPA Tier III off road emission standards) equipped with common rail direct fuel injection, variable geometry turbo charging, and interfaced with a custom built engine controller. The study found that injection timing greatly affected BFCE by changing the combustion phasing. BFCE would increase up to a maximum then begin to decrease as phasing became less favorable. Combustion phasing would change from being mostly mixing controlled combustion to premixed combustion as injection timing would advance allowing more time for fuel to mix during the ignition delay. Combustion phasing, in turn, would influence many other engine parameters. As injection timing is advanced, in-cylinder temperatures and pressures amplify, and intake and exhaust manifold pressures deteriorate. Rate of heat release and rate of heat transfer increase when injection timing is advanced. Turbocharger speed falls with the advancing injection timing. Torque, however, rose to a maximum then fell off again even though engine speed and fueling rate were held constant between different injection timings. Interestingly, the coefficient of heat transfer changes from a two peak curve to a smooth one peak curve as the injection timing is advanced further. The major conclusion of the study is that injection advance both positively and negatively influences the diesel engine's response which contributes to the brake fuel conversion efficiency.

McLean, James Elliott

2011-08-01T23:59:59.000Z

95

VEHICLE SPECIFICATIONS Vehicle Features Base Vehicle: 2010 Honda  

NLE Websites -- All DOE Office Websites (Extended Search)

Honda Honda Civic Hybrid VIN: JHMFA3F24AS005577 Seatbelt Positions: 5 Standard Features: Air Conditioning Power Locks Power Steering Power Brakes Power Windows Cruise Control Front Disc Brakes Rear Disc Brakes Front Wheel Drive Regenerative Braking Anti-Lock Brakes Traction Control Air Bags AM/FM Stereo with CD State of Charge Meter 1 Weights Design Curb Weight: 2877 lb Delivered Curb Weight: 2982 lb Distribution F/R (%): 57/43 GVWR: 3792 lb GAWR F/R: 1973/1841 lb Payload 2 : 810 lb Performance Goal: 400 lb Dimensions Wheelbase: 106.3 in Track F/R: 59.1/60.2 in Length: 177.3 in Width: 69.0 in Height: 56.3 in Ground Clearance: 6.0 in Performance Goal: 5.0 in Tires Manufacturer: Bridgestone

96

A study of factors affecting foot movement time in a braking maneuver  

E-Print Network (OSTI)

The nature of foot movement time (MT) in an actual braking maneuver and in a stationary vehicle was investigated regarding the effects of age and gender of the driver and nature of the stimulus to which the driver was responding. ANOVAs showed that the nature of the stimulus was not a significant factor in length of MT, but distance between pedals and age-gender levels were found to have significant effects. For the actual braking maneuver, gender and the gender-by-age interaction were significant; in the stationary vehicle portion of the study, they were not. Mean foot MT for both genders over all conditions were 0.28 seconds for women and 0.22 seconds for men. For older drivers, over all conditions, the mean foot MT was 0.25 seconds, and, for the younger drivers, 0.24 seconds. Linear regressions revealed high intra-subject variation in MT, which was corroborated by comparing with data from other parts of the study. Poor r2 values for fitting the data to Fitts' Law and to a modification of Fitts' Law were attributed to this high intra-subject variation and to obtaining data from only two different movement amplitudes. It was found that drivers' foot MTs tended to converge to a common value when controlling the vehicle at 88 km/hr (55 mph) as opposed to sitting in the driver's seat while the vehicle was stationary; mean foot MT for each subject group decreased, and differences between genders and age groups significantly diminished while the car was in motion.

Berman, Andrea Helene

1994-01-01T23:59:59.000Z

97

Air Quality  

NLE Websites -- All DOE Office Websites (Extended Search)

What We Monitor & Why » What We Monitor & Why » Air Quality Air Quality To preserve our existing wilderness-area air quality, LANL implements a conscientious program of air monitoring. April 12, 2012 Real-time data monitoring for particulate matter An air monitoring field team member tests one of LANL's tapered element oscillating microbalance samplers, which collects real-time particulate matter data. Contact Environmental Communication & Public Involvement P.O. Box 1663 MS M996 Los Alamos, NM 87545 (505) 667-0216 Email LANL monitors air quality 24 hours a day, 365 days a year. Why we monitor air LANL monitors many different pathways in order to assess their impact on workers, the public, animals, and plants. We monitor the air around the Laboratory to ensure our operations are not affecting the air of nearby

98

A Comparison of Three Voting Methods for Bagging with the MLEM2 Algorithm  

Science Conference Proceedings (OSTI)

This paper presents results of experiments on some data sets using bagging on the MLEM2 rule induction algorithm. Three different methods of ensemble voting, based on support (a non-democratic voting in which ensembles vote with their strengths), strength only (an ensemble with the largest strength decides to which concept a case belongs) and democratic voting (each ensemble has at most one vote) were used. Our conclusions are that though in most cases democratic voting was the best, it is not significantly better than voting based on support. The strength voting was the worst voting method.

Clinton Cohagan; Jerzy W. Grzymala-Busse; Zdzislaw S. Hippe

2010-03-17T23:59:59.000Z

99

Ga Air Compressor, Ga Air Compressor Products, Ga Air ...  

U.S. Energy Information Administration (EIA)

Ga Air Compressor, You Can Buy Various High Quality Ga Air Compressor Products from Global Ga Air Compressor Suppliers and Ga Air Compressor ...

100

Quark deconfinement in protoneutron star cores: effect of color superconductivity within the MIT bag model  

E-Print Network (OSTI)

We analyze the effect of color superconductivity in the transition from hot hadron matter to quark matter in the presence of a gas of trapped electron neutrinos. To describe strongly interacting matter we adopt a two-phase picture in which the hadronic phase is described by means of a non-linear Walecka model and just deconfined matter through the MIT bag model including color superconductivity. We impose flavor conservation during the transition in such a way that just deconfined quark matter is transitorily out of equilibrium with respect to weak interactions. Our results show that color superconductivity facilitates the transition for temperatures below $T_c$. This effect may be strong if the superconducting gap is large enough. As in previous work we find that trapped neutrinos increase the critical density for deconfinement; however, if the just deconfined phase is color superconducting this effect is weaker than if deconfined matter is unpaired. We also explore the effect of different parametrizations of the hadronic equation of state (GM1 and NL3) and the effect of hyperons in the hadronic phase. We compare our results with those previously obtained employing the Nambu-Jona-Lasinio model in the description of just deconfined matter and show that they are in excellent agreement if the bag constant $B$ is properly chosen.

Taiza A. S. do Carmo; Germn Lugones

2013-08-21T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


101

VEHICLE SPECIFICATIONS Vehicle Features  

NLE Websites -- All DOE Office Websites (Extended Search)

Mazda 3 Mazda 3 VIN: JMZBLA4G601111865 Seatbelt Positions: 5 Standard Features: Air Conditioning Power Locks Power Steering Power Brakes Power Windows Cruise Control Front Disc Brakes Rear Disc Brakes Front Wheel Drive Anti-Lock Brakes Traction Control Air Bags AM/FM Stereo with CD Weights Design Curb Weight: 2,954 lb Delivered Curb Weight: 2,850 lb Distribution F/R (%): 63/37 GVWR: 4,050 lb GAWR F/R: 2,057/1,896 lb Payload 1 : 1,096 lb Performance Goal: 400 lb Dimensions Wheelbase: 103.9 in Track F/R: 60.4/59.8 in Length: 175.6 in Width: 69.1 in Height: 57.9 in Ground Clearance: 6.1 in Performance Goal: 5.0 in Tires Manufacturer: Yokohama Model: YK520 Size: P205/55R17 Pressure F/R: 35/33 psi

102

VEHICLE SPECIFICATIONS Vehicle Features Base Vehicle: 2010 Smart  

NLE Websites -- All DOE Office Websites (Extended Search)

Smart Smart Fortwo MHD VIN: WME4513341K406476 Seatbelt Positions: 2 Standard Features: Air Conditioning Power Locks Power Steering Power Brakes Power Windows Cruise Control Front Disc Brakes Rear Drum Brakes Rear Wheel Drive Anti-Lock Brakes Traction Control Air Bags AM/FM Stereo with CD player Weights Design Curb Weight:1,818 lb Delivered Curb Weight: 1.742 lb Distribution F/R (%):44/56 GVWR: 2,244 lb GAWR F/R: 968/1,452 lb Payload 1 : 426 lb Performance Goal: 400 lb Dimensions Wheelbase: 73.5 in Track F/R: 50.5/54.5 in Length: 106.1 in Width: 61.4 in Height: 60.7 in Ground Clearance: 6.25 in Performance Goal: 5.0 in Tires Manufacturer: Continental Model: ContiproContact Size: Front -P155/60/R15

103

A preliminary assessment of asbestos awareness and control measures in brake and clutch repair services in Knoxville and Knox County, Tennessee  

SciTech Connect

The pending OSHA standard revision proposed in 1990 to lower the asbestos Permissible Exposure Limit (PEL) and to mandate effective asbestos control measures (ACM) in brake and clutch assembly work may have a profound effect on industries involved in such operations. Health protection of workers will be improved and costs of improved control methods and training will increase. Considering these facts, this preliminary study was designed to assess the level of worker and management awareness of asbestos hazards associated with brake and clutch repair and to determine what ACM had been implemented by businesses in Knoxville and Knox County, Tennessee. The study, in a metropolitan area of approximately 336,000 people, revealed eight different categories of businesses conducting brake and clutch repair work with an estimated 363 potentially exposed employees. Results of the study suggest that managers and employees of the 80 businesses studied were in need of asbestos hazard awareness training and more adequate asbestos control measures.

Phillips, C.C. (Oak Ridge National Lab., TN (United States)); Hamilton, C.B.

1994-04-01T23:59:59.000Z

104

Emissions of Criteria Pollutants, Toxic Air Pollutants, and Greenhouse Gases, From the Use of Alternative Transportation Modes and Fuels  

E-Print Network (OSTI)

acceleration energy recovered by regenerative braking Heavy-efficiencies, energy use by accessories, use of regenerativeregenerative braking can return up to 20% of propulsion energy;

Delucchi, Mark

1996-01-01T23:59:59.000Z

105

Air Resources: Prevention and Control of Air Contamination and Air  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Resources: Prevention and Control of Air Contamination and Air Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) Air Resources: Prevention and Control of Air Contamination and Air Pollution, Air Quality Classifications and Standards, and Air Quality Area Classifications (New York) < Back Eligibility Agricultural Fuel Distributor Industrial Institutional Investor-Owned Utility Local Government Multi-Family Residential Municipal/Public Utility Nonprofit Rural Electric Cooperative Schools State/Provincial Govt Transportation Tribal Government Utility Program Info State New York Program Type Environmental Regulations Provider NY Department of Environmental Conservation These regulations establish emissions limits and permitting and operational

106

IMPLEMENTING HEAT SEALED BAG RELIEF & HYDROGEN & METANE TESTING TO REDUCE THE NEED TO REPACK HANFORD TRANSURANIC (TRU) WASTE  

DOE Green Energy (OSTI)

The Department of Energy's site at Hanford has a significant quantity of drums containing heat-sealed bags that required repackaging under previous revisions of the TRUPACT-II Authorized Methods for Payload Control (TRAMPAC) before being shipped to the Waste Isolation Pilot Plant (WIPP). Since glovebox repackaging is the most rate-limiting and resource-intensive step for accelerating Hanford waste certification, a cooperative effort between Hanford's TRU Program and the WIPP site significantly reduced the number of drums requiring repackaging. More specifically, recent changes to the TRAMPAC (Revision 19C), allow relief for heat-sealed bags having more than 390 square inches of surface area. This relief is based on data provided by Hanford on typical Hanford heat-sealed bags, but can be applied to other sites generating transuranic waste that have waste packaged in heat-sealed bags. The paper provides data on the number of drums affected, the attendant cost savings, and the time saved. Hanford also has a significant quantity of high-gram drums with multiple layers of confinement including heat-scaled bags. These higher-gram drums are unlikely to meet the decay-heat limits required for analytical category certification under the TRAMPAC. The combination of high-gram drums and accelerated reprocessing/shipping make it even more difficult to meet the decay-heat limits because of necessary aging requirements associated with matrix depletion. Hydrogen/methane sampling of headspace gases can be used to certify waste that does not meet decay-heat limits of the more restrictive analytical category using the test category. The number of drums that can be qualified using the test category is maximized by assuring that the detection limit for hydrogen and methane is as low as possible. Sites desiring to ship higher-gram drums must understand the advantages of using hydrogen/methane sampling and shipping under the test category. Headspace gas sampling, as specified by the WIPP Waste Analysis Plan, provides the sample necessary for hydrogen/methane analysis. Most Hanford drums are not equipped with a filter through which a headspace gas sample can be obtained. A pneumatic system is now used to insert ''dart'' filters. The filters were developed by the vendor and approved for WIPP certification at the request of the Hanford Site. The same pneumatic system is used to install septum-type sample ports to allow the headspace to be sampled. Together, these steps allow the Hanford Site to avoid repackaging a large percentage of drums, and thus accelerate certification of waste destined for WIPP.

MCDONALD, K.M.

2005-01-20T23:59:59.000Z

107

Microsoft Word - chvs10.html  

NLE Websites -- All DOE Office Websites (Extended Search)

7 Chevrolet S-10 Electric 7 Chevrolet S-10 Electric VEHICLE SPECIFICATIONS PURPOSE-BUILT VEHICLE Base Vehicle: 1997 Chevrolet S-10 VIN: 1GCDE14H4V80003EX Seatbelt Positions: Three Standard Features: Heat Pump Climate Control System Auxillary Diesel Fuel Fired Heater (Only operates Below 40 F) Cruise Control Tilt Steering Wheel Front Wheel Drive Power Steering Power Brakes Anti-Lock Brakes Front Disk Brakes Regenerative Braking Drivers Side Air Bags AM/FM Stereo Radio Half-Bed Tonneau Cover BATTERY Manufacturer: Delphi Energy Type: Valve Regulated Lead Acid Number of Modules: 26 Weight of Module: 19 kg Weight of Pack(s): 575 kg Pack Locations: Underbody Nominal Module Voltage: 12 V Nominal System Voltage: 312 V Nominal Capacity (C/2): 48 Ah WEIGHTS Design Curb Weight: 4300 lbs

108

Model Based Structural Evaluation & Design of Overpack Container for Bag-Buster Processing of TRU Waste Drums  

Science Conference Proceedings (OSTI)

This paper describes a materials and computational model based analysis utilized to design an engineered overpack container capable of maintaining structural integrity for confinement of transuranic wastes undergoing the cryo-vacuum stress based Bag-Buster process and satisfying DOT 7A waste package requirements. The engineered overpack is a key component of the Ultra-BagBuster process/system being commercially developed by UltraTech International for potential DOE applications to non-intrusively breach inner confinement layers (poly bags/packaging) within transuranic (TRU) waste drums. This system provides a lower cost/risk approach to mitigate hydrogen gas concentration buildup limitations on transport of high alpha activity organic transuranic wastes. Four evolving overpack design configurations and two materials (low carbon steel and 300 series stainless) were considered and evaluated using non-linear finite element model analyses of structural response. Properties comparisons show that 300-series stainless is required to provide assurance of ductility and structural integrity at both room and cryogenic temperatures. The overpack designs were analyzed for five accidental drop impact orientations onto an unyielding surface (dropped flat on bottom, bottom corner, side, top corner, and top). The first three design configurations failed the bottom and top corner drop orientations (flat bottom, top, and side plates breached or underwent material failure). The fourth design utilized a protruding rim-ring (skirt) below the overpacks bottom plate and above the overpacks lid plate to absorb much of the impact energy and maintained structural integrity under all accidental drop loads at both room and cryogenic temperature conditions. Selected drop testing of the final design will be required to confirm design performance.

D. T. Clark; A. S. Siahpush; G. L. Anderson

2004-07-01T23:59:59.000Z

109

Air Pollution (Illinois)  

Energy.gov (U.S. Department of Energy (DOE))

This article states regulations for monitoring air pollution, methods for permit applications, emission limitations for pollutants and air quality standards.

110

Air Leakage of Furnaces and Air Handlers  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Leakage of Furnaces and Air Handlers Air Leakage of Furnaces and Air Handlers Title Air Leakage of Furnaces and Air Handlers Publication Type Journal Article LBNL Report Number LBNL-5553E Year of Publication 2010 Authors Walker, Iain S., Mile Lubliner, Darryl J. Dickerhoff, and William W. Delp Journal 2010 ACEEE Summer Study on Energy Efficiency in Buildings The Climate for efficiency is now Date Published 08/2010 Abstract In recent years, great strides have been made in reducing air leakage in residential and to a lesser extent small commercial forced air duct systems. Several authorities have introduced low leakage limits for thermal distribution systems; for example, the State of California Energy Code for Buildings gives credit for systems that leak less than 6% of the total air flow at 25 Pa.

111

Metal-Air Batteries  

Science Conference Proceedings (OSTI)

Metal-air batteries have much higher specific energies than most currently available primary and rechargeable batteries. Recent advances in electrode materials and electrolytes, as well as new designs on metal-air batteries, have attracted intensive effort in recent years, especially in the development of lithium-air batteries. The general principle in metal-air batteries will be reviewed in this chapter. The materials, preparation methods, and performances of metal-air batteries will be discussed. Two main metal-air batteries, Zn-air and Li-air batteries will be discussed in detail. Other type of metal-air batteries will also be described.

Zhang, Jiguang; Bruce, Peter G.; Zhang, Gregory

2011-08-01T23:59:59.000Z

112

Feasibility of air capture  

E-Print Network (OSTI)

Capturing CO2 from air, referred to as Air Capture, is being proposed as a viable climate change mitigation technology. The two major benefits of air capture, reported in literature, are that it allows us to reduce the ...

Ranjan, Manya

2010-01-01T23:59:59.000Z

113

Primary zone air proportioner  

SciTech Connect

An air proportioner is provided for a liquid hydrocarbon fueled gas turbine of the type which is convertible to oil gas fuel and to coal gas fuel. The turbine includes a shell for enclosing the turbine, an air duct for venting air in said shell to a gasifier, and a fuel injector for injecting gasified fuel into the turbine. The air proportioner comprises a second air duct for venting air from the air duct for mixing with fuel from the gasifier. The air can be directly injected into the gas combustion basket along with the fuel from the injector or premixed with fuel from the gasifier prior to injection by the fuel injector.

Cleary, Edward N. G. (San Diego, CA)

1982-10-12T23:59:59.000Z

114

Air Pollution Control (Indiana)  

Energy.gov (U.S. Department of Energy (DOE))

This legislation establishes the Department of Environmental Management and the Air Pollution Control Board, which are tasked with the prevention, abatement, and control of air pollution by all...

115

Energy Basics: Solar Air Heating  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

EERE: Energy Basics Solar Air Heating Solar air heating systems use air as the working fluid for absorbing and transferring solar energy. Solar air collectors (devices to heat air...

116

Isokinetic air sampler  

DOE Patents (OSTI)

An isokinetic air sampler includes a filter, a holder for the filter, an air pump for drawing air through the filter at a fixed, predetermined rate, an inlet assembly for the sampler having an inlet opening therein of a size such that isokinetic air sampling is obtained at a particular wind speed, a closure for the inlet opening and means for simultaneously opening the closure and turning on the air pump when the wind speed is such that isokinetic air sampling is obtained. A system incorporating a plurality of such samplers provided with air pumps set to draw air through the filter at the same fixed, predetermined rate and having different inlet opening sizes for use at different wind speeds is included within the ambit of the present invention as is a method of sampling air to measure airborne concentrations of particulate pollutants as a function of wind speed.

Sehmel, George A. (Richland, WA)

1979-01-01T23:59:59.000Z

117

Vermont Air Pollution Control Regulations, Ambient Air Quality...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ambient Air Quality Standards (Vermont) Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont) Eligibility Utility Agricultural Investor-Owned Utility...

118

Vsd Oil Free Air Compressor, Vsd Oil Free Air Compressor ...  

U.S. Energy Information Administration (EIA)

Vsd Oil Free Air Compressor, You Can Buy Various High Quality Vsd Oil Free Air Compressor Products from Global Vsd Oil Free Air Compressor Suppliers ...

119

China Ga Air Compressor, China Ga Air Compressor Products ...  

U.S. Energy Information Administration (EIA)

China Ga Air Compressor, China Ga Air Compressor Suppliers and Manufacturers Directory - Source a Large Selection of Ga Air Compressor Products at ...

120

Oil Free Vsd Air Compressor, Oil Free Vsd Air Compressor ...  

U.S. Energy Information Administration (EIA)

Oil Free Vsd Air Compressor, You Can Buy Various High Quality Oil Free Vsd Air Compressor Products from Global Oil Free Vsd Air Compressor Suppliers ...

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


121

Screw Type Ac Air Compressor Manufacturers, Screw Type Ac Air ...  

U.S. Energy Information Administration (EIA)

Screw Type Ac Air Compressor, Screw Type Ac Air Compressor Manufacturers & Suppliers Directory - Find here Screw Type Ac Air Compressor Traders, ...

122

Air Conditioning and lungs  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Conditioning and lungs Name: freeman Status: NA Age: NA Location: NA Country: NA Date: Around 1993 Question: What affect does air conditioning have upon the lungs of the...

123

Air Pollution- Local Air Quality (Ontario, Canada)  

Energy.gov (U.S. Department of Energy (DOE))

The Air Pollution regulation administered by the Ministry of the Environment enforces compliance to the standards set in the Ontario law. The law is phased in, with portions taking effect in 2010,...

124

Thin Air Breathing  

NLE Websites -- All DOE Office Websites (Extended Search)

Thin Air Breathing Thin Air Breathing Name: Amy Location: N/A Country: N/A Date: N/A Question: Why is it hard to breathe in thin air? What health dangers do mountain climbers face at high altitudes? Replies: Among the obvious dangers of losing ones footing, the oxygen available in the air is considerable less at higher altitudes. If I recall correctly, 21% of the atmosphere at standard temperature and pressure at sea level is composed of oxygen. This is less at higher altitudes. One can lose consciousness and even die in an oxygen deficient environment with changes from oxygen content to lower than 19.5%. This can unfortunate effect can occur within minutes. Dr. Myron The air is not really thin at high altitudes. The problem is that air pressure is lower. As altitude increases, air pressure decreases. In order for your lungs to fill with air, the air pressure in your lungs has to be less than the pressure of the air outside your lungs. Air moves from areas of higher pressure to lower pressure. As your diaphragm (the muscle that separates your chest cavity from your abdominal cavity) moves downward, the size of your chest cavity increases. This decreases the pressure in your chest and air flows in. When the diaphragm is up, it puts pressure on the chest cavity and the pressure in the lungs is greater than outside the lungs. Air flows out. This is an example of Boyle's Law. The movement of the diaphragm is controlled by the brainstem. Anyway-the reason that it is harder for some people to breathe at higher altitudes is that the air pressure differences aren't as great between the inside of the lungs and outside.

125

Environmental baseline monitoring in the area of general crude oil - Department of Energy Pleasant Bayou Number 1 - a geopressured-geothermal test well, 1978. Volume III. Appendix II. Air quality monitoring, Radian Corporation, Austin, Texas. Annual report  

DOE Green Energy (OSTI)

The air monitoring program, instrument types, and bag sampling program are described in each of five quarterly reports. The operating statistics for each of the major subsystems contained in the monitoring station are presented. National ambient air quality standards are presented for criteria pollutants and the monthly statistics for the monitoring station for the month are displayed. Daily averages, maximum daily five-minute averages retained in the data base as well as the times of occurrence, the five largest averages, and the diurnal variation of various recording times are tabulated. (MHR)

Gustavson, T.C.

1979-01-01T23:59:59.000Z

126

Indoor Air Quality Group  

Science Conference Proceedings (OSTI)

... CONTAM has been used at NIST to study the indoor air quality impacts of HVAC systems in single-family residential buildings, ventilation in large ...

2011-10-31T23:59:59.000Z

127

Air Resources Board  

E-Print Network (OSTI)

The Air Resources Board (the Board or ARB) will conduct a public hearing at the time and place noted below to consider amendments to the Verifkztion

unknown authors

2003-01-01T23:59:59.000Z

128

Air Resources Board  

E-Print Network (OSTI)

The Air Resources Board (the Board or ARB) will conduct a public hearing at the time and place noted below to consider amendments to the Verification

unknown authors

2003-01-01T23:59:59.000Z

129

Environmental Quality: Air (Louisiana)  

Energy.gov (U.S. Department of Energy (DOE))

The Department of Environmental Quality regulates air quality in Louisiana. The Department has an established a fee system for funding the monitoring, investigation and other activities required...

130

Air Pollution Project: Scenario  

NLE Websites -- All DOE Office Websites (Extended Search)

Project Summary HELP Index Summary Scenario Internet Links Student Pages SubjectContent Area: ScienceChemistry, Environment - Air Pollution Target Audience: High school chemistry...

131

Forced air fireplace furnace  

Science Conference Proceedings (OSTI)

The design of heating system for buildings including a fireplace with an open front hearth for burning firewood, a chimney extending from the upper portion of the hearth, a metal firebox being open in the front and closed on the sides and back, a plenum chamber within and surrounding the sides and back of the metal firebox and the chimney lower portion, a horizontal heat distribution chamber positioned in the building attic and communicating at one end with the plenum chamber is described. An air distribution duct connects to the other end of the air distributing chamber, the duct extending to discharge heated air to a place in the building remote from the fireplace. A fan is placed in the horizontal air distributing chamber, and a return air duct extends from selected place in the building and communicates with the plenum chamber lower portion so that the fan draws air through the return air duct, through the plenum chamber around the firebox where the air is heated, through the horizontal distribution chamber, and out through the distribution duct for circulation of the heated air within the building.

Bruce, R.W.; Gorman, R.E.

1980-10-28T23:59:59.000Z

132

Movements in air conditioning.  

E-Print Network (OSTI)

??Movements in Air Conditioning is a collection of poems that explores the obstacles inherent in creating a new sense of home in a country that (more)

Hitt, Robert D. (Robert David)

2013-01-01T23:59:59.000Z

133

Adsorption air conditioner  

DOE Patents (OSTI)

A solar powered air conditioner using the adsorption process is constructed with its components in a nested cylindrical array for compactness and ease of operation.

Rousseau, Jean L. I. (Redondo Beach, CA)

1979-01-01T23:59:59.000Z

134

Room Air Conditioners  

NLE Websites -- All DOE Office Websites (Extended Search)

of Superefficient Room Air Conditioners year month keywords appliance energy efficiency energy efficiency incentives Market Transformation standards url https isswprod lbl gov...

135

Air Pollution Controls  

Energy.gov (U.S. Department of Energy (DOE))

Various statutes within the Wisconsin Legislative Documents relate to air pollution control. These statutes describe zoning, permitting, and emissions regulations for hazardous and non-hazardous...

136

Recirculating electric air filter  

DOE Patents (OSTI)

An electric air filter cartridge has a cylindrical inner high voltage eleode, a layer of filter material, and an outer ground electrode formed of a plurality of segments moveably connected together. The outer electrode can be easily opened to remove or insert filter material. Air flows through the two electrodes and the filter material and is exhausted from the center of the inner electrode.

Bergman, Werner (Pleasanton, CA)

1986-01-01T23:59:59.000Z

137

Portable oven air circulator  

DOE Patents (OSTI)

A portable air circulating apparatus for use in cooking ovens which is used to create air currents in the oven which transfer heat to cooking foodstuffs to promote more rapid and more uniform cooking or baking, the apparatus including a motor, fan blade and housing of metallic materials selected from a class of heat resistant materials.

Jorgensen, Jorgen A. (Bloomington, MN); Nygren, Donald W. (Minneapolis, MN)

1983-01-01T23:59:59.000Z

138

Meeting the Air Leakage  

NLE Websites -- All DOE Office Websites (Extended Search)

Meeting the Air Leakage Meeting the Air Leakage Requirements of the 2012 IECC The U.S. Department of Energy (DOE) recognizes the enormous potential that exists for improving the energy efficiency, safety and comfort of homes. The newest edition of the International Energy Conservation Code ® (IECC) (2012) sets the bar higher for energy efficiency, and new air sealing requirements are one of the key new provisions. This guide is a resource for understanding the new air leakage requirements in the 2012 IECC and suggestions on how these new measures can be met. It also provides information from Building America's Air Sealing Guide, Best Practices and case studies on homes that are currently meeting the provisions. The 2012 IECC and a few International Residential Code (IRC) requirements are referenced throughout the guide.

139

Abatement of Air Pollution: Prohibition of Air Pollution (Connecticut)  

Energy.gov (U.S. Department of Energy (DOE))

All air pollution not otherwise covered by these regulations is prohibited. Stationary sources which cause air pollution must be operated in accordance with all applicable emissions standards and...

140

Abatement of Air Pollution: Prohibition of Air Pollution (Connecticut...  

Open Energy Info (EERE)

DEEP Air Management Department Department of Energy and Environmental Protection Division Environmental Protection Division; Bureau of Air Management Address 79 Elm Street Place...

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


141

Air ejector augmented compressed air energy storage system  

DOE Patents (OSTI)

Energy is stored in slack demand periods by charging a plurality of underground reservoirs with air to the same peak storage pressure, during peak demand periods throttling the air from one storage reservoir into a gas turbine system at a constant inlet pressure until the air pressure in the reservoir falls to said constant inlet pressure, thereupon permitting air in a second reservoir to flow into said gas turbine system while drawing air from the first reservoir through a variable geometry air ejector and adjusting said variable geometry air ejector, said air flow being essentially at the constant inlet pressure of the gas turbine system.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1980-01-01T23:59:59.000Z

142

Air Shower Simulations  

SciTech Connect

Air shower simulations are a vital part of the design of air shower experiments and the analysis of their data. We describe the basic features of air showers and explain why numerical simulations are the appropriate approach to model the shower simulation. The CORSIKA program, the standard simulation program in this field, is introduced and its features, performance and limitations are discussed. The basic principles of hadronic interaction models and some gerneral simulation techniques are explained. Also a brief introduction to the installation and use of CORSIKA is given.

Alania, Marco; Gomez, Adolfo V. Chamorro [Centro de Tecnologias de Informacion y Comunicaciones, Universidad Nacional de Ingenieria, Lima (Peru); Araya, Ignacio J. [Departamento de Astronomia y Astrofisica, Pontificia Universidad Catolica de Chile, Av. Vicuna Mackenna 4860, Santiago (Chile); Huerta, Humberto Martinez; Flores, Alejandra Parra [Facultad de Ciencias Fisico Matematicas, Benemerita Universidad Autonoma de Puebla, Puebla (Mexico); Knapp, Johannes [School of Physics and Astronomy, University of Leeds, Leeds LS2 9JT (United Kingdom)

2009-04-30T23:59:59.000Z

143

Air heating system  

DOE Patents (OSTI)

A self-starting, fuel-fired, air heating system including a vapor generator, a turbine, and a condenser connected in a closed circuit such that the vapor output from the vapor generator is conducted to the turbine and then to the condenser where it is condensed for return to the vapor generator. The turbine drives an air blower which passes air over the condenser for cooling the condenser. Also, a condensate pump is driven by the turbine. The disclosure is particularly concerned with the provision of heat exchanger and circuitry for cooling the condensed fluid output from the pump prior to its return to the vapor generator.

Primeau, John J. (19800 Seminole Rd., Euclid, OH 44117)

1983-03-01T23:59:59.000Z

144

Feature - Lithium-air Batteries  

NLE Websites -- All DOE Office Websites (Extended Search)

Develop Lithium-Air Battery Li-air Li-air batteries hold the promise of increasing the energy density of Li-ion batteries by as much as five to 10 times. But that potential will...

145

Air Carrier Flight Operations  

E-Print Network (OSTI)

Most air carriers operate under a system of prioritized goals including safety, customer service (on-time departures and arrivals) and operating economics. The flight operations department is responsible for the safe and ...

Midkif, Alan H.

146

AIR RESOURCES BOARD Acknowledgements  

E-Print Network (OSTI)

This report was prepared with the assistance and support from other agencies, divisions and offices of the Air Resources Board, and private firms. Staff would especially like to thank the following individuals for their assistance in developing this proposed pathway:

Green Wastes; Green Wastes; Richard Corey; Deputy Executive Officer; Cynthia Marvin Chief; Michael Waugh Chief; Kamal Ahuja; Brian Helmowski; Wes Ingram; Ray Asregadoo (arb; Juliet Bohn (hwma; Richard Boyd (arb; Alicia Chakrabarthy (ebmud; Steven Cliff (arb; Kevin Dickison (ebmud; Jacques Franco (calrecycle

2012-01-01T23:59:59.000Z

147

Breathing zone air sampler  

DOE Patents (OSTI)

A sampling apparatus is provided which comprises a sampler for sampling air in the breathing zone of a wearer of the apparatus and a support for the sampler preferably in the form of a pair of eyeglasses. The sampler comprises a sampling assembly supported on the frame of the eyeglasses and including a pair of sample transport tubes which are suspended, in use, centrally of the frame so as to be disposed on opposite sides of the nose of the wearer and which each include an inlet therein that, in use, is disposed adjacent to a respective nostril of the nose of the wearer. A filter holder connected to sample transport tubes supports a removable filter for filtering out particulate material in the air sampled by the apparatus. The sample apparatus is connected to a pump for drawing air into the apparatus through the tube inlets so that the air passes through the filter.

Tobin, John (Bethel Park, PA)

1989-01-01T23:59:59.000Z

148

air_water.cdr  

Office of Legacy Management (LM)

Office of Legacy Management Weldon Spring Site Air and Water Monitoring 32008 This fact sheet provides information at Weldon Spring, Missouri. This site is managed by the U.S....

149

Air Handling Unit Supply Air Temperature Optimization During Economizer Cycles  

E-Print Network (OSTI)

Most air handling units (AHUs) in commercial buildings have an air economizer cycle for free cooling under certain outside air conditions. During the economizer cycle, the outside air and return air dampers are modulated to seek mixing air temperature at supply air temperature setpoint. Mechanical cooling is always required when outside air temperature is higher than the supply air temperature setpoint. Generally the supply air temperature setpoint is set at 55F for space humidity control. Actually the dehumidification is not necessary when outside air dew point is less than 55F. Meanwhile the space may have less cooling load due to envelope heat loss and/or occupant schedule. These provide an opportunity to use higher supply air temperature to reduce or eliminate mechanical cooling and terminal box reheat. On the other hand the higher supply air temperature will require higher air flow as well as higher fan power. Therefore the supply air temperature has to be optimized to minimize the combined energy for fan, cooling and heating energy. In this paper a simple energy consumption model is established for AHU systems during the economizer and then a optimal supply air temperature control is developed to minimize the total cost of the mechanical cooling and the fan motor power. This paper presents AHU system energy modeling, supply air temperature optimization, and simulated energy savings.

Xu, K.; Liu, M.; Wang, G.; Wang, Z.

2007-01-01T23:59:59.000Z

150

Air Quality | Open Energy Information  

Open Energy Info (EERE)

Air Quality Jump to: navigation, search Retrieved from "http:en.openei.orgwindex.php?titleAirQuality&oldid612070" Category: NEPA Resources...

151

FREE AIR PRESSURE MEASUREMENTS  

SciTech Connect

Indenter gages, Wiancko gages, and interferometer gages were used to measure air overpressure vs time at essentially ground level stations for both the surface (S) and undprground (U) atomic explosions. For the S Burst several instruments were placed on a line extending from an overpressure region of 13 psi to a region of less than one psi. The air measurements for the U Burst ranged from 32 to 2 psi. (D. L.G.)

Howard, W.J.; Jones, R.D.

1952-02-19T23:59:59.000Z

152

Magnus air turbine system  

DOE Patents (OSTI)

A Magnus effect windmill for generating electrical power is disclosed. A large nacelle-hub mounted pivotally (in Azimuth) atop a support tower carries, in the example disclosed, three elongated barrels arranged in a vertical plane and extending symmetrically radially outwardly from the nacelle. The system provides spin energy to the barrels by internal mechanical coupling in the proper sense to cause, in reaction to an incident wind, a rotational torque of a predetermined sense on the hub. The rotating hub carries a set of power take-off rollers which ride on a stationary circular track in the nacelle. Shafts carry the power, given to the rollers by the wind driven hub, to a central collector or accumulator gear assembly whose output is divided to drive the spin mechanism for the Magnus barrels and the main electric generator. A planetary gear assembly is interposed between the collector gears and the spin mechanism functioning as a differential which is also connected to an auxiliary electric motor whereby power to the spin mechanism may selectively be provided by the motor. Generally, the motor provides initial spin to the barrels for start-up after which the motor is braked and the spin mechanism is driven as though by a fixed ratio coupling from the rotor hub. During high wind or other unusual conditions, the auxiliary motor may be unbraked and excess spin power may be used to operate the motor as a generator of additional electrical output. Interposed between the collector gears of the rotating hub and the main electric generator is a novel variable speed drive-fly wheel system which is driven by the variable speed of the wind driven rotor and which, in turn, drives the main electric generator at constant angular speed. Reference is made to the complete specification for disclosure of other novel aspects of the system such as, for example, the aerodynamic and structural aspects of the novel Magnus barrels as well as novel gearing and other power coupling combination apparatus of the invention. A reading of the complete specification is recommended for a full understanding of the principles and features of the disclosed system.

Hanson, Thomas F. (24204 Heritage La., Newhall, CA 91321)

1982-01-01T23:59:59.000Z

153

Air Cooling | Open Energy Information  

Open Energy Info (EERE)

Cooling Cooling Jump to: navigation, search Dictionary.png Air Cooling: Air cooling is commonly defined as rejecting heat from an object by flowing air over the surface of the object, through means of convection. Air cooling requires that the air must be cooler than the object or surface from which it is expected to remove heat. This is due to the second law of thermodynamics, which states that heat will only move spontaneously from a hot reservoir (the heat sink) to a cold reservoir (the air). Other definitions:Wikipedia Reegle Air Cooling Air Cooling Diagram of Air Cooled Condenser designed by GEA Heat Exchangers Ltd. (http://www.gea-btt.com.cn/opencms/opencms/bttc/en/Products/Air_Cooled_Condenser.html) Air cooling is limited on ambient temperatures and typically require a

154

InAir: sharing indoor air quality measurements and visualizations  

Science Conference Proceedings (OSTI)

This paper describes inAir, a tool for sharing measurements and visualizations of indoor air quality within one's social network. Poor indoor air quality is difficult for humans to detect through sight and smell alone and can contribute to the development ... Keywords: air quality, domestic technology, environment, health, iphone, persuasive technology, sensors, sustainability

Sunyoung Kim; Eric Paulos

2010-04-01T23:59:59.000Z

155

Comparison of nucleon form factors from lattice QCD against the light front cloudy bag model and extrapolation to the physical mass regime  

Science Conference Proceedings (OSTI)

We explore the possibility of extrapolating state of the art lattice QCD calculations of nucleon form factors to the physical regime. We find that the lattice results can be reproduced using the light front cloudy bag model by letting its parameters be analytic functions of the quark mass. We then use the model to extend the lattice calculations to large values of Q{sup 2} of interest to current and planned experiments. These functions are also used to define extrapolations to the physical value of the pion mass, thereby allowing us to study how the predicted zero in G{sub E}(Q{sup 2})/G{sub M}(Q{sup 2}) varies as a function of quark mass.

Matevosyan, Hrayr H.; Miller, Gerald A.; Thomas, Anthony W. [Louisiana State University, Department of Physics and Astronomy, 202 Nicholson Hall, Tower Dr., Baton Rouge, Louisiana 70803 (United States); and Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, Virginia 23606 (United States); University of Washington, Department of Physics, Box 351560, Seattle, Washington 98195-1560 (United States); Thomas Jefferson National Accelerator Facility, 12000 Jefferson Ave., Newport News, Virginia 23606 (United States)

2005-05-01T23:59:59.000Z

156

Compressed Air System Maintenance Guide  

Science Conference Proceedings (OSTI)

The "Compressed Air System Maintenance Guide" provides fossil plant personnel with information on the operation and maintenance of the compressed air system. The contents of this guide will assist personnel in improving performance of the compressed air system, reducing maintenance costs, and increasing air system reliability.

2002-11-27T23:59:59.000Z

157

Solar Buildings: Transpired Air Collectors  

DOE Green Energy (OSTI)

Transpired air collectors preheat building ventilation air by using the building's ventilation fan to draw fresh air through the system. The intake air is heated as it passes through the perforated absorber plate and up the plenum between the absorber and the south wall of the building. Reduced heating costs will pay for the systems in 3--12 years.

NONE

1998-11-24T23:59:59.000Z

158

air_water.cdr  

Office of Legacy Management (LM)

12/2011 12/2011 Air Monitoring Groundwater Monitoring Surface Water Monitoring A continuously operating air monitoring network was in place from 1986 through 2000 for the Weldon Spring Site Remedial Action Project (WSSRAP) to measure levels of gamma radiation, radioactive dust particles, radon gas, and asbestos. With remediation of contaminated materials essentially complete and measurements indistinguishable from background, the U.S. Department of Energy (DOE) ceased perimeter and offsite air monitoring as of December 31, 2000. Groundwater has been routinely monitored at the site since 1986. Separate groundwater monitoring programs were established for the Chemical Plant and Quarry sites because of geographic separation and differences in the hydrogeologic features that influence

159

Air Charter Services  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

42.2 (April 2012) 42.2 (April 2012) 1 Documentation and Approval of Federally Funded International Travel (Fly America Act-Open Skies Agreement) Overview This section provides guidance to DOE Contracting Officers, Contracting Officer Representatives, and Program Officials on documentation and approval of federally funded international travel by Federal contractors and subcontractors in accordance with FAR 52.247-63 PREFERENCE FOR U.S.-FLAG AIR CARRIERS (JUNE 2003), 49 U.S.C. §40118 (Fly America Act) and the Open Skies Agreements as amended. Background Contracts that include FAR clause 52.247-63, PREFERENCE FOR U.S.-FLAG AIR CARRIERS (JUNE 2003) as prescribed in FAR 47.405 require that, if available, the Contractor (and subcontractors), in performing work under the contract, shall use U.S.-flag air carriers for

160

AIR COOLED NEUTRONIC REACTOR  

DOE Patents (OSTI)

A nuclear reactor of the air-cooled, graphite moderated type is described. The active core consists of a cubicle mass of graphite, approximately 25 feet in each dimension, having horizontal channels of square cross section extending between two of the opposite faces, a plurality of cylindrical uranium slugs disposed in end to end abutting relationship within said channels providing a space in the channels through which air may be circulated, and a cadmium control rod extending within a channel provided in the moderator. Suitable shielding is provlded around the core, as are also provided a fuel element loading and discharge means, and a means to circulate air through the coolant channels through the fuel charels to cool the reactor.

Fermi, E.; Szilard, L.

1958-05-27T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


161

Compressed air energy storage system  

DOE Patents (OSTI)

An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

Ahrens, Frederick W. (Naperville, IL); Kartsounes, George T. (Naperville, IL)

1981-01-01T23:59:59.000Z

162

Inverter Controlled Screw Air Compressor Manufacturers ...  

U.S. Energy Information Administration (EIA)

Inverter Controlled Screw Air Compressor, Inverter Controlled Screw Air Compressor Manufacturers & Suppliers Directory - Find here Inverter ...

163

Solar air collector  

SciTech Connect

A solar heating system including a radiant heat collector apparatus made up of an enclosure having glazed panels. The collector provided within the enclosure is upstanding with the enclosure and the collector has heat absorbent flat walls spaced inwardly from the glazed panels. A heat storage core is provided centrally within the collector and spaced from the walls of the collector. The heat storage core includes an insulated housing and a heat retaining member within the insulated housing. Air passageways are formed between the collector walls and the insulated housing for passing input air, and duct members are provided for communicating with a household.

Deschenes, D.; Misrahi, E.

1981-12-15T23:59:59.000Z

164

Single-Duct Constant Air Volume System Supply Air Temperature Reset: Using Return Air Temperature or Outside Air Temperature?  

E-Print Network (OSTI)

The supply air temperature set point for a singleduct constant air volume air handling unit (AHU) system is often reset based on either return air temperature or outside air temperature in order to reduce simultaneous cooling and heating energy consumption. Both reset strategies make engineering sense as long as the reset schedules are reasonable. Quite often the decision to use one over the other is made with the assumption that they will all achieve some sorts of energy savings. However, the impact of these two strategies on AHU energy consumption could be very different. A comparison of these two commonly used supply air temperature reset strategies for a single-duct constant air volume system is presented in this paper. It is shown that from either the building energy consumption or building comfort point of view, the reset strategy based on outside air temperature is inherently better than that based on return air temperature. Significant amount of heating energy savings can be achieved by switching from return air temperature based reset to outside air temperature based reset. The reset strategy can also benefit variable air volume (VAV) AHUs. An improved supply air temperature set point reset control strategy is proposed by combining and staging the outside air and return air temperature based resets.

Wei, G.; Turner, W. D.; Claridge, D.; Liu, M.

2002-01-01T23:59:59.000Z

165

Hexane Air Combustion  

E-Print Network (OSTI)

Hot surface ignition and subsequent flame propagation of premixed n-hexane air mixtures are shown in this fluid dynamics video. High speed schlieren photography revealed 3 distinct behaviors of ignition and propagation as a function of mixture composition and initial pressure.

Boettcher, Philipp A; Shepherd, Joseph E

2010-01-01T23:59:59.000Z

166

Air-cleaning apparatus  

SciTech Connect

An air-cleaning, heat-exchange apparatus includes a main housing portion connected by means of an air inlet fan to the kitchen exhaust stack of a restaurant. The apparatus includes a plurality of heat exchangers through which a heat-absorptive fluid is circulated, simultaneously, by means of a suitable fluid pump. These heat exchangers absorb heat from the hot exhaust gas, out of the exhaust stack of the restaurant, which flows over and through these heat exchangers and transfers this heat to the circulating fluid which communicates with remote heat exchangers. These remote heat exchangers further transfer this heat to a stream of air, such as that from a cold-air return duct for supplementing the conventional heating system of the restaurant. Due to the fact that such hot exhaust gas is heavily grease laden , grease will be deposited on virtually all internal surfaces of the apparatus which this exhaust gas contacts. Consequently, means are provided for spraying these contacted internal surfaces , as well as the hot exhaust gas itself, with a detergent solution in which the grease is soluble, thereby removing grease buildup from these internal surfaces.

Howard, A.G.

1981-08-18T23:59:59.000Z

167

Winter Morning Air Temperature  

Science Conference Proceedings (OSTI)

Results of temperature measurements, which may be applied to inference of winter temperatures in data-sparse areas, are presented. The morning air temperatures during three winters were measured at 80 places in a 10 km 30 km area along the ...

A. Hogan; M. Ferrick

1997-01-01T23:59:59.000Z

168

Air Proportional Counter  

DOE Patents (OSTI)

A multiple wire counter utilizing air at atmospheric pressure as the ionizing medium and having a window of a nylon sheet of less than 0.5 mil thickness coated with graphite. The window is permeable to alpha particles so that the counter is well adapted to surveying sources of alpha radiation.

Simpson, J.A. Jr.

1950-10-31T23:59:59.000Z

169

Vermont Air Pollution Control Regulations, Ambient Air Quality Standards (Vermont)  

Energy.gov (U.S. Department of Energy (DOE))

The ambient air quality standards are based on the national ambient air quality standards. The Vermont standards are classified as primary and secondary standards and judged adequate to protect...

170

Utilizing intake-air oxygen-enrichment technology to reduce cold- phase emissions  

DOE Green Energy (OSTI)

Oxygen-enriched combustion is a proven, serious considered technique to reduce exhaust hydrocarbons (HC) and carbon monoxide (CO) emissions from automotive gasoline engines. This paper presents the cold-phase emissions reduction results of using oxygen-enriched intake air containing about 23% and 25% oxygen (by volume) in a vehicle powered by a spark-ignition (SI) engine. Both engineout and converter-out emissions data were collected by following the standard federal test procedure (FTP). Converter-out emissions data were also obtained employing the US Environmental Protection Agency`s (EPA`s) ``Off-Cycle`` test. Test results indicate that the engine-out CO emissions during the cold phase (bag 1) were reduced by about 46 and 50%, and HC by about 33 and 43%, using nominal 23 and 25% oxygen-enriched air compared to ambient air (21% oxygen by volume), respectively. However, the corresponding oxides of nitrogen (NO{sub x}) emissions were increased by about 56 and 79%, respectively. Time-resolved emissions data indicate that both HC and CO emissions were reduced considerably during the initial 127 s of the cold-phase FTP, without any increase in NO, emissions in the first 25 s. Hydrocarbon speciation results indicate that all major toxic pollutants, including ozone-forming specific reactivity factors, such as maximum incremental reactivity (NUR) and maximum ozone incremental reactivity (MOIR), were reduced considerably with oxygen-enrichment. Based on these results, it seems that using oxygen-enriched intake air during the cold-phase FTP could potentially reduce HC and CO emissions sufficiently to meet future emissions standards. Off-cycle, converter-out, weighted-average emissions results show that both HC and CO emissions were reduced by about 60 to 75% with 23 or 25% oxygen-enrichment, but the accompanying NO{sub x}, emissions were much higher than those with the ambient air.

Poola, R.B.; Ng, H.K.; Sekar, R.R. [Argonne National Lab., IL (United States); Baudino, J.H. [Autoresearch Labs., Inc., Chicago, IL (United States); Colucci, C.P. [National Renewable Energy Lab., Golden, CO (United States)

1995-12-31T23:59:59.000Z

171

Air Conditioning | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Conditioning Conditioning Air Conditioning July 1, 2012 - 6:28pm Addthis Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ©iStockphoto/JaniceRichard Air conditioners cost U.S. homeowners more than $11 billion each year, and regular maintenance can keep your air conditioner running efficiently. | Photo courtesy of ©iStockphoto/JaniceRichard How does it work? An air conditioner uses energy -- usually electricity -- to transfer heat from the interior of your home to the relatively warm outside environment. Two-thirds of all homes in the United States have air conditioners. Air conditioners use about 5% of all the electricity produced in the United States, at an annual cost of more than $11 billion to homeowners. As a

172

Judging Air Quality Model Performance  

Science Conference Proceedings (OSTI)

Under the direction of the AMS Steering Committee for the EPA Cooperative Agreement on air quality modeling, a small group of scientists was convened to review and recommend procedures to evaluate the performance of air quality models. Particular ...

Douglas G. Fox

1981-05-01T23:59:59.000Z

173

Oil and Gas Air Heaters  

E-Print Network (OSTI)

Most conventional air heaters adopt indirect heat transfer, which uses combustion gases to indirectly heat fresh air by heating surfaces to generate hot air used for material drying and dehumidification. We call them indirect air heaters. However, they have a higher manufacturing cost and lower thermal efficiency, especially when high temperature air is needed. For this reason, a direct air heater applicable for or feed and industrial raw products is put forward, which has advantages such as less production cost, smaller dimensions and higher thermal efficiency. Their design, working principles, characteristics, structure and applications are presented in this article, and brief comparisons are made between the indirect and direct air heater. Finally, the relation of hot-air temperature, oil or gas consumption and fresh airflow is determined based on energy equilibrium.

Kou, G.; Wang, H.; Zhou, J.

2006-01-01T23:59:59.000Z

174

Computer controlled air conditioning systems  

SciTech Connect

This patent describes an improvement in a computer controlled air conditioning system providing for circulation of air through an air conditioned house in contact with concrete walls requiring a humidity within a critical range. The improvement consists of: a computer for processing sensed environmental input data including humidity and oxygen to produce output control signals for affecting the humidity of the air in the house; provision for an air flow circulation path through the house in contact with the concrete walls; sensing responsive to the amount of oxygen in the house for providing input signals to the computer; mixing for combining with the air in the house a variable amount of fresh atmospheric air to supply fresh oxygen; and humidity modifying means for modifying the humidity of the air flowing in the flow path responsive to the control signals.

Dumbeck, R.F.

1986-02-04T23:59:59.000Z

175

Louisiana Air Control Law (Louisiana)  

Energy.gov (U.S. Department of Energy (DOE))

This law states regulations for air quality control and states the powers and duties of the secretary of environmental quality. It provides information about permits and licenses, air quality...

176

Uncertainty in Air Quality Modeling  

Science Conference Proceedings (OSTI)

Under the direction of the AMS Steering Committee for the EPA Cooperative Agreement on Air Quality Modeling, a small group of scientists convened to consider the question of uncertainty in air quality modeling. Because the group was particularly ...

Douglas G. Fox

1984-01-01T23:59:59.000Z

177

Air cathode structure manufacture  

DOE Patents (OSTI)

An improved air cathode structure for use in primary batteries and the like. The cathode structure includes a matrix active layer, a current collector grid on one face of the matrix active layer, and a porous, nonelectrically conductive separator on the opposite face of the matrix active layer, the collector grid and separator being permanently bonded to the matrix active layer. The separator has a preselected porosity providing low IR losses and high resistance to air flow through the matrix active layer to maintain high bubble pressure during operation of the battery. In the illustrated embodiment, the separator was formed of porous polypropylene. A thin hydrophobic film is provided, in the preferred embodiment, on the current collecting metal grid.

Momyer, William R. (Palo Alto, CA); Littauer, Ernest L. (Los Altos Hills, CA)

1985-01-01T23:59:59.000Z

178

Compressed Air 101: Getting Compressed Air to Work  

E-Print Network (OSTI)

"Air compressors are a significant industrial energy user. Based on a survey (conducted by Oregon State University and the Bonneville Power Administration) of energy audit reports from 125 plants, air compressors account for roughly 10% of total plant energy use. Furthermore, air compression is inefficient with up to 95% of compressor power dissipated as heat. Thus even minor improvements in system operation, control strategies, and efficiency can yield large energy savings and significant non-energy or productivity benefits from reliable compressed air. Compressed air is often called the ""fourth utility"" in industrial facilities after electricity, natural gas, and water. It provides motive power for machinery, cooling, materials handling, and hand tools. It is a safe, flexible, and powerful resource, but one that is seldom run for low operating costs or best productivity. Learning the basics of compressed air systems represents the beginning of both reducing energy costs and enjoying the productive benefits of reliable compressed air. Compressed air management systems, including a system approach to managing demand, stabilizing pressure, reducing leaks and compressor controls, can allow the industrial end user to save 20% - 50% of their air compressor electricity usage. The monitoring capabilities of compressed air management systems provide a useful tool through power, pressure and flow trending to maintain both the energy savings and increased system reliability. More efficiently managed compressed air systems are less costly to maintain and have less impact on the environment. The most important issues of industrial compressed air in relation to energy efficiency and management are: 1. Compressed air is an essential industrial utility; 2. Compressing air is a fundamentally inefficient energy transformation process; 3. Optimal operation of compressed air systems in industrial plants is seldom a priority and adequate management infonnation is rare, resulting in negative impacts on production and even less efficiency."

Burke, J. J.; Bessey, E. G.

2003-05-01T23:59:59.000Z

179

Solar air conditioning  

DOE Green Energy (OSTI)

Development of a hybrid solar-assisted air conditioning system that combines a vapor compression section for sensible cooling with a desiccant section for dehumidification and that uses both solar energy and condenser waste heat to drive the dehumidifier has been under way for the last two years (1981 and 1982). The results of this research are included in this report: utilizing solar energy in an economical way has proven quite difficult.

Robison, H.

1981-01-01T23:59:59.000Z

180

Air Resources Board  

E-Print Network (OSTI)

The Air Resources Board (ARB or Board) will conduct a public hearing at the time and place noted below to consider adoption of the Proposed Airborne Toxic Control Measure (ATCM) to Reduce Formaldehyde Emissions from Composite Wood Products. The proposed ATCM would reduce the publics current exposure to formaldehyde by reducing emissions from hardwood plywood (HWPW), particleboard (PB) and medium density fiberboard (MDF) panels. The ATCM would also apply to finished goods made with these materials.

unknown authors

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


181

Metal-air battery assessment  

DOE Green Energy (OSTI)

The objective of this report is to evaluate the present technical status of the zinc-air, aluminum/air and iron/air batteries and assess their potential for use in an electric vehicle. In addition, this report will outline proposed research and development priorities for the successful development of metal-air batteries for electric vehicle application. 39 refs., 25 figs., 11 tabs.

Sen, R.K.; Van Voorhees, S.L.; Ferrel, T.

1988-05-01T23:59:59.000Z

182

Microsoft Word - solcar95.html  

NLE Websites -- All DOE Office Websites (Extended Search)

FORCE FORCE VEHICLE SPECIFICATIONS CONVERTED VEHICLE Base Vehicle: 1995 Geo Metro VIN:2C1MR529XS6783464 Seatbelt Positions: Three Standard Features: Power Brakes Front Disk Brakes Front Wheel Drive Dual Air Bags AM/FM Stereo Radio w/Cassette Electric Heater Options as Tested: None BATTERY Manufacturer: GM Ovonic Type: 13.2EV85 Nickel Metal Hydride Number of Modules: 14 Weight of Module: 18 kg Weight of Pack(s): 254 kg Pack Locations: Undertrunk/Underhood Nominal Module Voltage: 13.2 V Nominal System Voltage: 185 V Nominal Capacity (1C): 85 Ah WEIGHTS Design Curb Weight: 2246 lbs Delivered Curb Weight: 2304 lbs Distribution F/R: 50/50 % GVWR: 2755 lbs GAWR F/R: 1432/1366 lbs Payload: 451 lbs Performance Goal: 664 lbs DIMENSIONS Wheelbase: 93.5 inches

183

Microsoft Word - s10.html  

NLE Websites -- All DOE Office Websites (Extended Search)

Chevrolet S-10 Electric Chevrolet S-10 Electric w/NiMH VEHICLE SPECIFICATIONS PURPOSE-BUILT VEHICLE Base Vehicle: 1998 S-10 VIN: 1GCDE14H1W8122580 Seatbelt Positions: Three Standard Features: Heat Pump Climate Control System Auxillary Diesel Fuel Fired Heater (Only operates Below 37°F) Cruise Control Power Steering Tilt Steering Wheel 4-wheel Anti-Lock Power Assisted Brakes Regenerative Braking Propulsion Battery Thermal Management System Driver and Passenger-Side Air Bags (w/Passenger-Side Deactivation Switch) AM/FM Stereo Radio Half-Bed Tonneau Cover BATTERY Manufacturer: Ovonic Energy Products Type: Nickel Metal Hydride Number of Modules: 26 Weight of Module: 18.3 kg Weight of Pack(s): 490.5 kg Pack Locations: Underbody Nominal Module Voltage: 13.2 V

184

Transpired Air Collectors - Ventilation Preheating  

DOE Green Energy (OSTI)

Many commercial and industrial buildings have high ventilation rates. Although all that fresh air is great for indoor air quality, heating it can be very expensive. This short (2-page) fact sheet describes a technology available to use solar energy to preheat ventilation air and dramatically reduce utility bills.

Christensen, C.

2006-06-22T23:59:59.000Z

185

California Air Resources Board | Open Energy Information  

Open Energy Info (EERE)

Air Resources Board Jump to: navigation, search Logo: California Air Resources Board Name California Air Resources Board Place Sacramento, California Website http:www.arb.ca.gov...

186

Review of air flow measurement techniques  

E-Print Network (OSTI)

rate and air leakage tests under reductive sealing for anfor subsequent sealing, the openings of air infiltrationreductive sealing between the reductions in measured air

McWilliams, Jennifer

2002-01-01T23:59:59.000Z

187

Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Island) |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Island) Air Pollution Control Regulations: No. 22 - Air Toxics (Rhode Island) < Back Eligibility Commercial Industrial Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Rhode Island Program Type Siting and Permitting Provider Department of Environmental Management Permits are required to construct, install, or modify any stationary source which has the potential to increase emissions of a listed toxic air contaminant by an amount greater than the minimum quantity for that contaminant. Minimum quantities are specified in Table III of these regulations. Permits will be granted based in part on the impact of the projected emissions of the stationary source on acceptable ambient levels

188

Urban and Regional Air Quality  

NLE Websites -- All DOE Office Websites (Extended Search)

equipment equipment Urban and Regional Air Quality Research in this area is concerned with regional air quality issues such as: Controlling nitrogen oxides (NOx) and volatile organic compounds, to manage tropospheric ozone pollution. Hazardous air pollutants: using science to base standards on rigorously studied risks. Air quality and climate: how does climate influence air quality at a regional or local level? Current modeling practices often do not capture variations in pollutants such as ozone-they represent a limited sample of the diverse meteorology and human behavior that affect air pollution. Improved modeling of regional air quality will help understand variability, reveal patterns of behavior, and pollutant transport issues. Controlled experiments in lab and field can help validate improved models.

189

Regenerative air heater  

DOE Patents (OSTI)

A gas-cooled steel skirt is used to support a refractory cored brick matrix and dome structure in a high temperature regenerative air heater useful in magnetohydrodynamic power generation. The steel skirt thermally expands to accommodate the thermal expansion of the dome structure despite substantial temperature differential thereby reducing relative movement between the dome bricks. Gas cooling of the steel skirt allows the structure to operate above its normal temperature during clean-out cycles and also allows for the control of the thermal expansion of the steel skirt.

Hasselquist, Paul B. (Maple Grove, MN); Baldner, Richard (Minnetonka, MN)

1982-01-01T23:59:59.000Z

190

Regenerative air heater  

DOE Patents (OSTI)

A gas-cooled steel skirt is used to support a refractory cored brick matrix and dome structure in a high temperature regenerative air heater useful in magnetohydrodynamic power generation. The steel skirt thermally expands to accommodate the thermal expansion of the dome structure despite substantial temperature differential thereby reducing relative movement between the dome bricks. Gas cooling of the steel skirt allows the structure to operate above its normal temperature during clean-out cycles and also allows for the control of the thermal expansion of the steel skirt.

Hasselquist, P.B.; Baldner, R.

1980-11-26T23:59:59.000Z

191

Retrofit Air Preheat Economics  

E-Print Network (OSTI)

Retrofit air preheat systems are the most reliable and efficient means to effect significant energy conservation for large existing industrial furnaces. Units can be quickly installed without a lengthy shutdown, and the furnace efficiency can be increased to a range of 89% to 92%. The economic justification for the addition of this equipment is presented in new total investment curves and simple payout curves for a range of fuel cost. This will enable the owner to quickly determine the preliminary feasibility and conceptual requirements for his project before proceeding with more vigorous work.

Goolsbee, J. A.

1981-01-01T23:59:59.000Z

192

Hot air drum evaporator  

DOE Patents (OSTI)

An evaporation system for aqueous radioactive waste uses standard 30 and 55 gallon drums. Waste solutions form cascading water sprays as they pass over a number of trays arranged in a vertical stack within a drum. Hot dry air is circulated radially of the drum through the water sprays thereby removing water vapor. The system is encased in concrete to prevent exposure to radioactivity. The use of standard 30 and 55 gallon drums permits an inexpensive compact modular design that is readily disposable, thus eliminating maintenance and radiation build-up problems encountered with conventional evaporation systems.

Black, Roger L. (Idaho Falls, ID)

1981-01-01T23:59:59.000Z

193

Abatement of Air Pollution: Hazardous Air Pollutants (Connecticut)  

Energy.gov (U.S. Department of Energy (DOE))

These regulations describe maximum allowable stack concentrations and hazard limiting values for the emission of hazardous air pollutants. The regulations also discuss sampling procedures for...

194

Abatement of Air Pollution: Hazardous Air Pollutants (Connecticut...  

Open Energy Info (EERE)

requirements. Policy Contact Contact Name Anne Gobin Department Department of Energy & Environmental Protection Division Bureau of Air Management Phone (860) 424-3026...

195

Air temperature thresholds for indoor comfort and perceived air quality  

E-Print Network (OSTI)

Moving air for comfort. ASHRAE Journal, May, Arens, E. ,17-22, Copenhagen. . ASHRAE Standard 55- 2010. ThermalSensations of Sedentary Man, ASHRAE Transactions, Vol. 80 (

Zhang, Hui; Edward, Arens; Pasut, Wilmer

2012-01-01T23:59:59.000Z

196

Reactive Air Aluminization  

DOE Green Energy (OSTI)

Ferritic stainless steels and other alloys are of great interest to SOFC developers for applications such as interconnects, cell frames, and balance of plant components. While these alloys offer significant advantages (e.g., low material and manufacturing cost, high thermal conductivity, and high temperature oxidation resistance), there are challenges which can hinder their utilization in SOFC systems; these challenges include Cr volatility and reactivity with glass seals. To overcome these challenges, protective coatings and surface treatments for the alloys are under development. In particular, aluminization of alloy surfaces offers the potential for mitigating both evaporation of Cr from the alloy surface and reaction of alloy constituents with glass seals. Commercial aluminization processes are available to SOFC developers, but they tend to be costly due to their use of exotic raw materials and/or processing conditions. As an alternative, PNNL has developed Reactive Air Aluminization (RAA), which offers a low-cost, simpler alternative to conventional aluminization methods.

Choi, Jung-Pyung; Chou, Y. S.; Stevenson, Jeffry W.

2011-10-28T23:59:59.000Z

197

Reduce Air Infiltration in Furnaces  

Science Conference Proceedings (OSTI)

This DOE Industrial Technologies Program tip sheet describes how to save energy and costs by reducing air infiltration in industrial furnaces; tips include repairing leaks and increasing insulation.

Not Available

2006-01-01T23:59:59.000Z

198

Oklahoma Clean Air Act (Oklahoma)  

Energy.gov (U.S. Department of Energy (DOE))

This legislation establishes the authority for the Oklahoma Department of Environmental Quality to administer programs to maintain and monitor air quality across Oklahoma. The Department monitors...

199

Optimization of Air Conditioning Cycling.  

E-Print Network (OSTI)

??Systems based on the vapor compression cycle are the most widely used in a variety of air conditioning applications. Despite the vast growth of modern (more)

Seshadri, Swarooph

2012-01-01T23:59:59.000Z

200

Air Conditioning | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

environment. An air conditioner uses a cold indoor coil called the evaporator. The condenser, a hot outdoor coil, releases the collected heat outside. The evaporator and...

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


201

Air Kerma - High Energy Xray  

Science Conference Proceedings (OSTI)

... such as high energy megavoltage x rays with peak voltages of at least 5 MV. Currently, air-kerma measurements at these high energies are not ...

2013-03-13T23:59:59.000Z

202

Industrial HVAC Air-to-Air Energy Recovery Retrofit Economics  

E-Print Network (OSTI)

Retrofitting air-to-air energy recovery equipment is relatively simply to design and easy to install. Additionally, HVAC energy recovery is almost risk free when compared to process retrofit. Life cycle cost analysis is the best way to illustrate the economic attractiveness of retrofitting HVAC industrial energy recovery equipment.

Graham, E. L.

1980-01-01T23:59:59.000Z

203

Air distribution effectiveness with stratified air distribution systems  

E-Print Network (OSTI)

, Ph.D Qingyan Chen, Ph.D. Student Member ASHRAE Fellow ASHRAE ABSTRACT Stratified air distribution distribution systems has been taken into consideration by the ASHRAE standards through the air distribution effectiveness. For example, Table 6-1 of ANSI/ASHRAE Standard 62.1-2004 (ASHRAE 2004) defines the minimum

Chen, Qingyan "Yan"

204

Brake System Modeling and Control  

E-Print Network (OSTI)

of 3447 kPa Upper Left: Volts vs. Angular Position, showingone cycle. Lower Right: Volts vs. Position at several brakewith a magnitude of several volts. The INA118, a precision

Hedrick, J. K.; Uchanski, M.

2001-01-01T23:59:59.000Z

205

Mechanical and Hydraulic Press Brakes  

Science Conference Proceedings (OSTI)

...drives, with mechanical linkages from motor to flywheel to clutch to gears to crankshaft to crank arm to ram (Fig. 4). They all have one thing in common: a crankshaft action that converts rotary motion into straight, reciprocating motion (Fig. 5). During a stroke cycle, the crank arm drives the ram down...

206

Air conditioning: Impact on the built environment  

Science Conference Proceedings (OSTI)

The topics discussed in this book are: Introduction. 1. Air Conditioning - An Ever Expanding Market. 2. Building Envelope Design and Air Contitioning. 3. Air Conditioning and Energy - The CIBSE Building Energy Code. 4. Thermal Storage in Air Conditioning Systems. 5. Good Practice in the Design and Construction of Air Conditioning Systems. 6. Software for Air Conditioning Load Analysis and Design. 7. Lloyd's of London - The Architecture of Air Conditioning - Prediction of the Environment.

Sherratt, A.F.C.

1987-01-01T23:59:59.000Z

207

VSD/VFD Screw air compressor, Kunshan CompAirs Machinery Plant ...  

U.S. Energy Information Administration (EIA)

VSD/VFD Screw air compressor,Kunshan CompAirs Machinery Plant Co.,Ltd is the leading air compressor manufacturer and exporter in china, Professional ...

208

Protective supplied breathing air garment  

DOE Patents (OSTI)

A breathing air garment is disclosed for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap. 17 figs.

Childers, E.L.; Hortenau, E.F. von.

1984-07-10T23:59:59.000Z

209

Protective supplied breathing air garment  

DOE Patents (OSTI)

A breathing air garment for isolating a wearer from hostile environments containing toxins or irritants includes a suit and a separate head protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit rear torso panel permits access into the suit and is sealed with an adhesive sealing flap.

Childers, Edward L. (Lakewood, CO); von Hortenau, Erik F. (Golden, CO)

1984-07-10T23:59:59.000Z

210

The Clean Air Mercury Rule  

SciTech Connect

Coming into force on July 15, 2005, the US Clean Air Mercury Rule will use a market-based cap-and-trade approach under Section 111 of the Clean Air Act to reduce mercury emissions from the electric power sector. This article provides a comprehensive summary of the new rule. 14 refs., 2 tabs.

Michael Rossler [Edison Electric Institute, Washington, DC (US)

2005-07-01T23:59:59.000Z

211

air conditioner | OpenEI  

Open Energy Info (EERE)

air conditioner air conditioner Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

212

Air Force Renewable Energy Programs  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 1 Ken Gray P.E. HQ AFCESA /CENR Air Force Renewable Energy Programs April, 2011 FUPWG "Make Energy a Consideration in All We Do" I n t e g r i t y - S e r v i c e - E x c e l l e n c e THINK GREEN, BUILD GREEN, Topics  Air Force Energy Use  Air Force Facility Energy Center  Current RE Generation  Project Development System  Programmed RE Generation FY11-13  Goal Achievement 2 I n t e g r i t y - S e r v i c e - E x c e l l e n c e THINK GREEN, BUILD GREEN, Air Force 2010 Energy Use The Air Force spent approximately $8.2 billion for energy in 2010; an increase of 22% from 2009 Energy Cost and Consumption Trends Energy Cost Breakdown Aviation 79% Facilities 17% 3 Aviation 84% Facilities 12% Vehicles & Equipment

213

High Efficiency Particulate Air Filters  

NLE Websites -- All DOE Office Websites (Extended Search)

High Efficiency Particulate Air (HEPA) Filters High Efficiency Particulate Air (HEPA) Filters Home Standards DOE Workshops Nuclear Air Cleaning Conference Proceedings Qualified Filter List News Items Related Sites HEPA Related Lessons Learned Contact Us HSS Logo High Efficiency Particulate Air Filters The HEPA Filter web site provides a forum for informing and reporting department-wide activities related to filtration and ventilation issues with special reference to the High Efficiency Particulate Air (HEPA) Filters' use, inspection, and testing. This site contains essentials of DOE HEPA filter test program, procedures, requirements and quality assurance aspects applicable to HEPA filters used in DOE facilities. This site contains information about the DOE-accepted Filter Test Facility and its management, operation and quality assuranceprogram.

214

NETL: IEP - Air Quality Research  

NLE Websites -- All DOE Office Websites (Extended Search)

Home > Technologies > Coal & Power Systems > Innovations for Existing Plants > Air Quality Research Home > Technologies > Coal & Power Systems > Innovations for Existing Plants > Air Quality Research Innovations for Existing Plants Air Quality Research Ambient Monitoring Emissions Characterization Predictive Modeling & Evaluation Health Effects Regulatory Drivers Air Quality Research Reference Shelf The NETL Air Quality Research program is designed to resolve the scientific uncertainties associated with the atmospheric formation, distribution, and chemical transformation of pollutant emissions from today's coal-fired power plants, and to obtain a realistic assessment of the human health impacts of these emissions. Results of this research will help the DOE Office of Fossil Energy address policy questions regarding coal plant emissions and provide guidance for future emissions control R&D programs at

215

Powdered coal air dispersion nozzle  

SciTech Connect

An improved coal/air dispersion nozzle introduces fuel into the combustion chamber of a gas turbine engine as a finely atomized, dispersed spray for a uniform combustion. The nozzle has an inlet that receives finely powdered coal from a coal transport or coal/air fluidizer system and a scroll swirl generator is included within the nozzle to swirl a fluidized coal/air mixture supplied to the inlet of the nozzle. The scroll is in the form of a thin, flat metal sheet insert, twisted along its length, and configured to prevent build-up of coal particles within the nozzle prior to ejection from its outlet. Airblast air jets are included along the length of the nozzle body to assist in the discharge of the fluidized coal from the nozzle outlet and an angular pintle tip overlies the outlet to redirect coal/air mixture through a desired fluidized coal spray angle.

Kosek, T.P.; Steinhilper, E.A.

1981-10-27T23:59:59.000Z

216

NETL: Water-Energy Interface - Improvement to Air2Air Technology...  

NLE Websites -- All DOE Office Websites (Extended Search)

cooling tower with relatively drier and cooler ambient air. This is done in an air-to-air heat exchanger made up of plastic sheets with two discreet air pathways. As the warm,...

217

Indoor air radon  

SciTech Connect

This review concerns primarily the health effects that result from indoor air exposure to radon gas and its progeny. Radon enters homes mainly from the soil through cracks in the foundation and other holes to the geologic deposits beneath these structures. Once inside the home the gas decays (half-life 3.8 d) and the ionized atoms adsorb to dust particles and are inhaled. These particles lodge in the lung and can cause lung cancer. The introduction to this review gives some background properties of radon and its progeny that are important to understanding this public health problem as well as a discussion of the units used to describe its concentrations. The data describing the health effects of inhaled radon and its progeny come both from epidemiological and animal studies. The estimates of risk from these two data bases are consistent within a factor of two. The epidemiological studies are primarily for hard rock miners, although some data exist for environmental exposures. The most complete studies are those of the US, Canadian, and Czechoslovakian uranium miners. Although all studies have some deficiencies, those of major importance include uranium miners in Saskatchewan, Canada, Swedish iron miners, and Newfoundland fluorspar miners. These six studies provide varying degrees of detail in the form of dose-response curves. Other epidemiological studies that do not provide quantitative dose-response information, but are useful in describing the health effects, include coal, iron ore and tin miners in the UK, iron ore miners in the Grangesburg and Kiruna, Sweden, metal miners in the US, Navajo uranium miners in the US, Norwegian niobian and magnitite miners, South African gold and uranium miners, French uranium miners, zinc-lead miners in Sweden and a variety of small studies of environmental exposure. An analysis of the epidemiological studies reveals a variety of interpretation problem areas.172 references.

Cothern, C.R.

1990-01-01T23:59:59.000Z

218

Analysis of Efficiency Standards for Air Conditioners, Air ...  

U.S. Energy Information Administration (EIA)

Federal agencies to select ENERGY STAR and ... analyze the proposed air conditioner and heat pump standards, a new baseline ... square foot office building 0.4 to 0.8 ...

219

Central Air Conditioning | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Central Air Conditioning Central Air Conditioning Central Air Conditioning May 30, 2012 - 8:01pm Addthis Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ©iStockphoto/DonNichols. Central air conditioners circulate cool air through a system of supply and return ducts. | Photo courtesy of ©iStockphoto/DonNichols. What does this mean for me? Central air conditioning systems are thermostatically controlled and convenient to use. Central air conditioning systems must be installed properly to operate efficiently. Central air conditioning systems can share ductwork with your heating system. Central air conditioners circulate cool air through a system of supply and return ducts. Supply ducts and registers (i.e., openings in the walls,

220

Tips: Sealing Air Leaks | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Sealing Air Leaks Sealing Air Leaks Tips: Sealing Air Leaks May 16, 2013 - 5:03pm Addthis Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Air leaks can waste a lot of your energy dollars. One of the quickest energy-- and money-saving tasks you can do is caulk, seal, and weather strip all seams, cracks, and openings to the outside. Tips for Sealing Air Leaks Test your home for air tightness. On a windy day, carefully hold a lit incense stick or a smoke pen next to your windows, doors, electrical

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


221

Tips: Sealing Air Leaks | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Sealing Air Leaks Tips: Sealing Air Leaks Tips: Sealing Air Leaks May 16, 2013 - 5:03pm Addthis Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Sources of Air Leaks in Your Home. Areas that leak air into and out of your home cost you a lot of money. The areas listed in the illustration are the most common sources of air leaks. Air leaks can waste a lot of your energy dollars. One of the quickest energy-- and money-saving tasks you can do is caulk, seal, and weather strip all seams, cracks, and openings to the outside. Tips for Sealing Air Leaks Test your home for air tightness. On a windy day, carefully hold a lit incense stick or a smoke pen next to your windows, doors, electrical

222

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Room Air Conditioners Room Air Conditioners Room Air Conditioners July 1, 2012 - 5:35pm Addthis A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. A window air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/kschulze. What does this mean for me? Room air conditioners are less expensive and disruptive to install than central air conditioning systems. Room air conditioners can be a cost-effective alternative to central air conditioning systems. How does it work? Room air conditioners work by cooling one part of your home. Room or window air conditioners cool rooms rather than the entire home or business. If they provide cooling only where they're needed, room air conditioners are less expensive to operate than central units, even though

223

SolarAire LLC | Open Energy Information  

Open Energy Info (EERE)

SolarAire LLC Place Folsom, California Sector Solar Product Developing a solar thermal air conditioning unit. References SolarAire LLC1 LinkedIn Connections CrunchBase Profile...

224

DunoAir | Open Energy Information  

Open Energy Info (EERE)

DunoAir Jump to: navigation, search Name DunoAir Place Hessen, Germany Zip 6865 VX Sector Wind energy Product Doorwerth-based wind project developer. References DunoAir1 LinkedIn...

225

Rooftop Unitary Air Conditioner with Integral Dedicated Outdoor Air System  

SciTech Connect

Energy use of rooftop and other unitary air-conditioners in commercial applications accounts for about 1 quad (10{sup 15} Btu) of primary energy use annually in the U.S. [Reference 7]. The realization that this cooling equipment accounts for the majority of commercial building cooled floorspace and the majority also of commercial building energy use has spurred development of improved-efficiency equipment as well as development of stricter standards addressing efficiency levels. Another key market driver affecting design of rooftop air-conditioning equipment has been concern regarding comfort and the control of humidity. Trends for increases in outdoor air ventilation rates in certain applications, and the increasing concern about indoor air quality problems associated with humidity levels and moisture in buildings points to a need for improved dehumidification capability in air-conditioning equipment of all types. In many cases addressing this issue exacerbates energy efficiency, and vice versa. The integrated dedicated outdoor air system configuration developed in this project addresses both energy and comfort/humidity issues.

Tiax Llc

2006-02-28T23:59:59.000Z

226

Mountain Air | Open Energy Information  

Open Energy Info (EERE)

Air Air Jump to: navigation, search Name Mountain Air Facility Mountain Air Sector Wind energy Facility Type Commercial Scale Wind Facility Status In Service Owner Terna Energy Developer Terna Energy Energy Purchaser Idaho Power Location Hammett ID Coordinates 42.98719519°, -115.3985024° Loading map... {"minzoom":false,"mappingservice":"googlemaps3","type":"ROADMAP","zoom":14,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"geoservice":"google","maxzoom":false,"width":"600px","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"copycoords":false,"static":false,"wmsoverlay":"","layers":[],"controls":["pan","zoom","type","scale","streetview"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"kml":[],"gkml":[],"fusiontables":[],"resizable":false,"tilt":0,"kmlrezoom":false,"poi":true,"imageoverlays":[],"markercluster":false,"searchmarkers":"","locations":[{"text":"","title":"","link":null,"lat":42.98719519,"lon":-115.3985024,"alt":0,"address":"","icon":"","group":"","inlineLabel":"","visitedicon":""}]}

227

Kansas Air Quality Regulations (Kansas)  

Energy.gov (U.S. Department of Energy (DOE))

All new air contaminant emission sources or alterations to emission sources that are required to be reported shall be in compliance with all applicable emission control regulations at the time that...

228

Manual on indoor air quality  

Science Conference Proceedings (OSTI)

This reference manual was prepared to assist electric utilities in helping homeowners, builders, and new home buyers to understand a broad range of issues related to indoor air quality. The manual is directed to technically knowledgeable persons employed by utility companies - the customer service or marketing representative, applications engineer, or technician - who may not have specific expertise in indoor air quality issues. In addition to providing monitoring and control techniques, the manual summarizes the link between pollutant concentrations, air exchange, and energy conservation and describes the characteristics and health effects of selected pollutants. Where technical information is too lengthy or complex for inclusion in this volume, reference sources are given. Information for this manual was gathered from technical studies, manufacturers' information, and other materials from professional societies, institutes, and associations. The aim has been to provide objective technical and descriptive information that can be used by utility personnel to make informed decisions about indoor air quality issues.

Diamond, R.C.; Grimsrud, D.T.

1983-12-01T23:59:59.000Z

229

Kansas Air Quality Act (Kansas)  

Energy.gov (U.S. Department of Energy (DOE))

No person shall construct, own, operate, install, alter or use any air contaminant emission stationary source which, in accordance with rules and regulations, the secretary finds may cause or...

230

Nadir Correction of AIRS Radiances  

Science Conference Proceedings (OSTI)

A statistical method to correct for the limb effect in off-nadir Atmospheric Infrared Sounder (AIRS) channel radiances is described, using the channel radiance itself and principal components (PCs) of the other channel radiances to account for ...

Chee-Kiat Teo; Tieh-Yong Koh

2010-03-01T23:59:59.000Z

231

buy vsd air compressor - high quality Manufacturers,Suppliers ...  

U.S. Energy Information Administration (EIA)

vsd air compressor trade offers directory and vsd air compressor business offers list. Trade leads from vsd air compressor Suppliers and vsd air ...

232

Indoor Air Quality and Volatile Organic Compounds  

Science Conference Proceedings (OSTI)

... The unit was sized to comply with the outdoor air requirements in ASHRAE Standard 62.2 Ventilation and Acceptable Indoor Air Quality in Low ...

2013-03-12T23:59:59.000Z

233

Aire Valley Environmental | Open Energy Information  

Open Energy Info (EERE)

search Name Aire Valley Environmental Place United Kingdom Product Leeds-based waste-to-energy project developer. References Aire Valley Environmental1 LinkedIn...

234

Radionuclide Air Emission Report for 2011  

E-Print Network (OSTI)

LBNL-470E-201 Radionuclide Air Emission Report for Preparedfor Emissions of Radionuclides Other Than Radon FromFugitive Air Emissions of Radionuclides from Diffuse Sources

Wahl, Linnea

2012-01-01T23:59:59.000Z

235

Radionuclide Air Emission Report for 2008  

E-Print Network (OSTI)

Fugitive Air Emissions of Radionuclides from Diffuse SourcesHazardous Air Pollutants (Radionuclides), Availability ofLBNL to Revise Its Radionuclide NESHAP Monitoring Approach,

Wahl, Linnea

2009-01-01T23:59:59.000Z

236

Central Air conditioners | Open Energy Information  

Open Energy Info (EERE)

Page Edit History Facebook icon Twitter icon Central Air conditioners Jump to: navigation, search TODO: Add description List of Central Air conditioners Incentives Retrieved...

237

Review of air flow measurement techniques  

E-Print Network (OSTI)

chamber, passive sampling, passive solar house, measurementhouse, we planed the distribution of fresh air, passivepassive perfluorocarbon tracer technique for determining air infiltration rates into houses

McWilliams, Jennifer

2002-01-01T23:59:59.000Z

238

Air permitting of IGCC plants  

SciTech Connect

The IGCC process is, currently, the preferred choice over conventional thermal power production in regard to cleanup of fuel and significantly reduced contaminant emissions. The air permitting requirements include the review of: feed preparation and PM emissions; feed gasification and contaminant emissions; elemental sulfur recovery and SO{sub 2} emissions; options for carbon-dioxide recovery; syngas characteristics for combustion; CT design and combustion mechanisms; air contaminant emissions of CT; controlled CT emissions of nitrogen-oxides and carbon-monoxide gases using the SCR and oxidation catalysts, respectively; and, emission of volatile organic compounds (VOCs), and hazardous air pollutants (HAPs). However, the IGCC processes are being rigorously reviewed for the system integration and reliability, and significant reduction of air contaminant emissions (including the greenhouse gases). This paper included a review of IGCC air contaminant emission rates, and various applicable regulatory requirements, such as NSR (New Source Review), NSPS (New Source Performance Standards), and MACT (Maximum Achievable Control Technology). The IGCC facility's NOX, CO, SO{sub 2}, PM, VOCs, and HAPs emission rates would be significantly low. Thus, effective, construction and installation, and operation air permits would be necessary for IGCC facilities.

Chitikela, S.R.

2007-07-01T23:59:59.000Z

239

Common Air Conditioner Problems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

240

Common Air Conditioner Problems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Common Air Conditioner Problems Common Air Conditioner Problems Common Air Conditioner Problems May 30, 2012 - 6:41pm Addthis A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. A refrigerant leak is one common air conditioning problem. | Photo courtesy of ©iStockphoto/BanksPhotos. What does this mean for me? You can eliminate the most common air conditioner problems before hiring an air conditioning technician. You can do some air conditioner maintenance and repair tasks yourself. One of the most common air conditioning problems is improper operation. If your air conditioner is on, be sure to close your home's windows and outside doors. For room air conditioners, isolate the room or a group of connected rooms as much as possible from the rest of your home.

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


241

Supply Fan Control for Constant Air Volume Air Handling Units  

E-Print Network (OSTI)

Since terminal boxes do not have a modulation damper in constant volume (CV) air handling unit (AHU) systems, zone reheat coils have to be modulated to maintain the space temperature with constant supply airflow. This conventional control sequence causes a significant amount of reheat and constant fan power under partial load conditions. Variable Frequency Drives (VFDs) can be installed on these constant air volume systems. The fan speed can be modulated based on the maximum zone load. This paper present the procedure to control the supply fan speed and analyzes the thermal performance and major fan energy and thermal energy savings without expensive VAV retrofit through the actual system operation.

Cho, Y.; Wang, G.; Liu, M.

2007-01-01T23:59:59.000Z

242

Improved intake air filtration systems  

SciTech Connect

This report comprises the results of a project sponsored by the Pipeline Research Committee of the American Gas Association (Improved Intake Air Filtration Systems). The quality of the inlet air consumed by pipeline gas turbines plays a significant role in the performance, maintenance, and economy of turbine operations. The airborne contaminants may cause degradation of compressor blades and hot gas path components, primarily by erosion, corrosion, and fouling. Machines in the pipeline fleet have a typical average loss of 3.5% in output, chiefly caused by fouling of the gas turbine compressor. It also showed that: Air contamination could be significantly reduced by the use of more efficient air filtration systems, especially through the reduction of the quantity of smaller particles ingested.'' Filters which incorporated electrostatically charged fibers (achieved through the use of triboelectric [TE] effects) offered the most promising means for developing an improvement over paper media. The purpose of this program was to validate the use of new technology for self-cleaning air inlet filtration on gas turbine pumping applications. An approach utilizing triboelectrification of fabric filters was examined by testing to determine the penetration (efficiency), cleanability, pressure drop vs flow, and dust-holding capacity of seven pairs of filter cartridges: six fabric and one paper.

Lawson, C.C. (Lawson (Calvin C.), North Wildwood, NJ (United States))

1991-09-01T23:59:59.000Z

243

Air Breathing Direct Methanol Fuel Cell  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Breathing Direct Methanol Fuel Cell Air Breathing Direct Methanol Fuel Cell Air Breathing Direct Methanol Fuel Cell An air breathing direct methanol fuel cell is provided with a membrane electrode assembly, a conductive anode assembly that is permeable to air and directly open to atmospheric air, and a conductive cathode assembly that is permeable to methanol and directly contacting a liquid methanol source. Available for thumbnail of Feynman Center (505) 665-9090 Email Air Breathing Direct Methanol Fuel Cell An air breathing direct methanol fuel cell is provided with a membrane electrode assembly, a conductive anode assembly that is permeable to air and directly open to atmospheric air, and a conductive cathode assembly that is permeable to methanol and directly contacting a liquid methanol

244

Tips: Air Ducts | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Ducts Air Ducts Tips: Air Ducts June 24, 2013 - 7:23pm Addthis Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Air Ducts: Out of Sight, Out of Mind. The unsealed ducts in your attic and crawlspaces lose air, and uninsulated ducts lose heat -- wasting energy and money. Your air ducts are one of the most important systems in your home, and if the ducts are poorly sealed or insulated they are likely contributing to higher energy bills. Your home's duct system is a branching network of tubes in the walls, floors, and ceilings; it carries the air from your home's furnace and central air conditioner to each room. Ducts are made of sheet metal, fiberglass, or other materials.

245

Air Showers and Geomagnetic Field  

E-Print Network (OSTI)

The influence of the geomagnetic field on the development of air showers is studied. The well known International Geomagnetic Reference Field was included in the AIRES air shower simulation program as an auxiliary tool to allow calculating very accurate estimations of the geomagnetic field given the geographic coordinates, altitude above sea level and date of a given event. Our simulations indicate that the geomagnetic deflections alter significantly some shower observables like, for example, the lateral distribution of muons in the case of events with large zenith angles (larger than 75 degrees). On the other hand, such alterations seem not to be important for smaller zenith angles. Global observables like total numbers of particles or longitudinal development parameters do not present appreciable dependences on the geomagnetic deflections for all the cases that were studied.

A. Cillis; S. J. Sciutto

1999-07-31T23:59:59.000Z

246

Considering Air Density in Wind Power Production  

E-Print Network (OSTI)

In the wind power production calculations the air density is usually considered as constant in time. Using the CIPM-2007 equation for the density of moist air as a function of air temperature, air pressure and relative humidity, we show that it is worth taking the variation of the air density into account, because higher accuracy can be obtained in the calculation of the power production for little effort.

Zn Farkas

2011-03-11T23:59:59.000Z

247

Investigation of Feasibility of All-Fresh Air Supply in an All-Air System  

E-Print Network (OSTI)

The feasibility of an all-fresh air supply in an all-air system is investigated in theory, and the problem of AHU-handling air in low efficiency in summer and winter conditions is analyzed. The air supply temperature is almost up to standards when a heat recovery unit is fixed in the air conditioning system.

Wang, J.; Yan, Z.

2006-01-01T23:59:59.000Z

248

inAir: Measuring and Visualizing Indoor Air Quality Sunyoung Kim & Eric Paulos  

E-Print Network (OSTI)

, air quality, domestic computing, health ACM Classification Keywords H.m. Information interfacesinAir: Measuring and Visualizing Indoor Air Quality Sunyoung Kim & Eric Paulos Human}@cs.cmu.edu ABSTRACT Good indoor air quality is a vital part of human health. Poor indoor air quality can contribute

Paulos, Eric

249

I) EXAS AIR CONTROL BLAR  

NLE Websites -- All DOE Office Websites (Extended Search)

I) EXAS AIR CONTROL BLAR 6330 HWY. 290 EAST, AUSTIN, TEXAS 78723, 512451-5711 DICK WHmINGTON, P.E. JOHN L. BLAIR CHAIRMAN MARCUS M. KEY, M.D. CALVIN 8. PARNELL, JR., Ph.D., P.E....

250

Air-leakage control manual  

Science Conference Proceedings (OSTI)

This manual is for builders and designers who are interested in building energy-efficient homes. The purpose of the manual is to provide the ``how and why`` of controlling air leakage by means of a system called the ``Simple Caulk and Seal`` (SIMPLE{center_dot}CS) system. This manual provides an overview of the purpose and contents of the manual; It discusses the forces that affect air leakage in homes and the benefits of controlling air leakage. Also discussed are two earlier approaches for controlling air leakage and the problems with these approaches. It describes the SIMPLE-{center_dot}CS system. It outlines the standard components of the building envelope that require sealing and provides guidelines for sealing them. It outlines a step-by-step procedure for analyzing and planning the sealing effort. The procedure includes (1) identifying areas to be sealed, (2) determining the most effective and convenient stage of construction in which to do the sealing, and (3) designating the appropriate crew member or trade to be responsible for the sealing.

Maloney, J. [Washington State Energy Office, Olympia, WA (United States)

1991-05-01T23:59:59.000Z

251

Air-Leakage Control Manual.  

Science Conference Proceedings (OSTI)

This manual is for builders and designers who are interested in building energy-efficient homes. The purpose of the manual is to provide the how and why'' of controlling air leakage by means of a system called the Simple Caulk and Seal'' (SIMPLE{center dot}CS) system. This manual provides an overview of the purpose and contents of the manual; It discusses the forces that affect air leakage in homes and the benefits of controlling air leakage. Also discussed are two earlier approaches for controlling air leakage and the problems with these approaches. It describes the SIMPLE-{center dot}CS system. It outlines the standard components of the building envelope that require sealing and provides guidelines for sealing them. It outlines a step-by-step procedure for analyzing and planning the sealing effort. The procedure includes (1) identifying areas to be sealed, (2) determining the most effective and convenient stage of construction in which to do the sealing, and (3) designating the appropriate crew member or trade to be responsible for the sealing.

Maloney, Jim; Washington State Energy Office; United States. Bonneville Power Administration.

1991-05-01T23:59:59.000Z

252

220-MW compressed air storage  

Science Conference Proceedings (OSTI)

SOYLAND Power Cooperative, Inc., a Decatur, Illinois based co-op, could get reasonably priced baseload power from neighboring utilities, had a plant of its own planned for the near future as well as a share in another, but peaking power, generated by oil and gas, to meet surges in demand, was very costly. The co-op's solution, first in the U.S., is a 220-megawatt compressed air energy storage system (CAES), which the electric utility industry is watching with great interest. CAES splits the two basic stages of a conventional gas turbine, making the most of baseload power while using the least peaking or intermediate fuel. During off-peak periods, inexpensive baseload electricity from coal or nuclear power plants runs a combination motor-generator in motor mode which, in turn, operates a compressor. The compressed air is cooled and pumped into an underground storage reservoir hundreds of thousands of cubic yards in volume and about two thousand feet (about 610 m) below the surface. There the air remains, at pressures up to about 60 atm (6.1 MPa), until peaking or intermediate power is required. Then, the air is released into a combustor at a controlled rate, heated by oil or gas, and expanded through a turbine. The turbine drives the motor-generator in a generator mode, thereby supplying peaking or intermediate power to the grid.

Lihach, N.

1983-01-01T23:59:59.000Z

253

ISOTHERMAL AIR INGRESS VALIDATION EXPERIMENTS  

SciTech Connect

Idaho National Laboratory carried out air ingress experiments as part of validating computational fluid dynamics (CFD) calculations. An isothermal test loop was designed and set to understand the stratified-flow phenomenon, which is important as the initial air flow into the lower plenum of the very high temperature gas cooled reactor (VHTR) when a large break loss-of-coolant accident occurs. The unique flow characteristics were focused on the VHTR air-ingress accident, in particular, the flow visualization of the stratified flow in the inlet pipe to the vessel lower plenum of the General Atomics Gas Turbine-Modular Helium Reactor (GT-MHR). Brine and sucrose were used as heavy fluids, and water was used to represent a light fluid, which mimics a counter current flow due to the density difference between the stimulant fluids. The density ratios were changed between 0.87 and 0.98. This experiment clearly showed that a stratified flow between simulant fluids was established even for very small density differences. The CFD calculations were compared with experimental data. A grid sensitivity study on CFD models was also performed using the Richardson extrapolation and the grid convergence index method for the numerical accuracy of CFD calculations . As a result, the calculated current speed showed very good agreement with the experimental data, indicating that the current CFD methods are suitable for predicting density gradient stratified flow phenomena in the air-ingress accident.

Chang H Oh; Eung S Kim

2011-09-01T23:59:59.000Z

254

Air Sealing Your Home | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Sealing Your Home Air Sealing Your Home Air Sealing Your Home November 26, 2013 - 6:22pm Addthis Save on heating and cooling costs by checking for air leaks in common trouble spots in your home. Save on heating and cooling costs by checking for air leaks in common trouble spots in your home. What does this mean for me? Save money and energy by air sealing your house. Caulking and weatherstripping are simple, effective ways of sealing air leaks in your home. Reducing the amount of air that leaks in and out of your home is a cost-effective way to cut heating and cooling costs, improve durability, increase comfort, and create a healthier indoor environment. Caulking and weatherstripping are two simple and effective air-sealing techniques that offer quick returns on investment, often one year or less. Caulk is

255

Maintaining Your Air Conditioner | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Maintaining Your Air Conditioner Maintaining Your Air Conditioner Maintaining Your Air Conditioner June 18, 2013 - 6:20pm Addthis Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. What does this mean for me? Regular maintenance keeps your air conditioner running as efficiently as possible. Maintaining your air conditioner will save you money by extending the unit's life. An air conditioner's filters, coils, and fins require regular maintenance for the unit to function effectively and efficiently throughout its years of service. Neglecting necessary maintenance ensures a steady decline in air conditioning performance while energy use steadily increases.

256

Maintaining Your Air Conditioner | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Maintaining Your Air Conditioner Maintaining Your Air Conditioner Maintaining Your Air Conditioner June 18, 2013 - 6:20pm Addthis Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. Replacing or cleaning air conditioner filters is a critical maintenance task. | Photo courtesy of ©iStockphoto/firemanYU. What does this mean for me? Regular maintenance keeps your air conditioner running as efficiently as possible. Maintaining your air conditioner will save you money by extending the unit's life. An air conditioner's filters, coils, and fins require regular maintenance for the unit to function effectively and efficiently throughout its years of service. Neglecting necessary maintenance ensures a steady decline in air conditioning performance while energy use steadily increases.

257

Optimal Outside Air Control for Air Handling Units with Humidity Control  

E-Print Network (OSTI)

Most air handling units (AHUs) in commercial buildings have the (air) economizer cycle to use outside air for free cooling under certain outside air conditions. Ideally the economizer cycle is enabled if outside air enthalpy is less than return air enthalpy. During the economizer cycle, outside air flow is modulated to seek mixed air temperature at a supply air temperature set point. Since the outside air may be dry during the economizer cycle, humidification is required for AHUs with humidity control. As a result, the economizer cycle saves cooling energy but requires excessive steam for humidification. Therefore the economizer cycle may not be economical. An optimal outside air control method is developed to minimize the total cost of mechanical cooling and steam humidification. The impacts of chilled water price, steam price, and space minimum humidity set point are analyzed. Finally the optimal outside air control zones are presented on a psychrometric chart under differential energy price ratios and minimum indoor humidity set points.

Wang, G.; Liu, M.

2006-01-01T23:59:59.000Z

258

AIR FORCE SPECIAL WEAPONS CENTER  

Office of Legacy Management (LM)

HEADQUARTERS aII?y HEADQUARTERS aII?y 9 AIR FORCE SPECIAL WEAPONS CENTER 1 AIR FORCE SYSTEMS COMMAND . - KlRTlAND AIR FORCE BASE, NEW MEXICO - k FINAL REPORT O N AIR FORCE PARTICIPATION PROJECT RULISON .1 O c t o b e r 1969 P r e p a r e d by : CONT INENTAL TEST D I V I S ION DIRECTORATE OF NUCLEAR FIELD OPERATIONS This page intentionally left blank INDEX AIR FORCE PARTICIPATION I N PROJECT RULISON FINAL REPORT PARAGRAPH BASIC REPORT SUBJECT R e f e r e n c e s PAGE 2 G e n e r a l 1 3 P l a n n i n g 3 4 Command a n d C o n t r o l 5 O p e r a t i o n s , G r a n d ' J u n c t i o n M u n i c i p a l A i r p o r t . . ' A i r O p e r a t i o n s C e n t e r , He1 i c o p t e r P a d / ' 7.. - . M a t e r i e l : ' 8 M e d i c a l 1 9 R a d - S a f e C r a s h - R e s c u e S e c u r i t y 2 1 C o m m u n i c a t i o n s ~ d m i n i s t r a t ' i o n Summary ATTACHMENTS ATTACHMENT SUBJECI' 1 F r a g O r d e r 69-1 ( ~ r o j ' e c t RULISON) , AFSWC D

259

Air Pollution Control (Oklahoma) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Pollution Control (Oklahoma) Air Pollution Control (Oklahoma) Air Pollution Control (Oklahoma) < Back Eligibility Agricultural Fuel Distributor Industrial Investor-Owned Utility Local Government Municipal/Public Utility Rural Electric Cooperative State/Provincial Govt Systems Integrator Tribal Government Utility Savings Category Buying & Making Electricity Program Info State Oklahoma Program Type Environmental Regulations Provider Environmental Quality This chapter enumerates primary and secondary ambient air quality standards and the significant deterioration increments. Significant deterioration refers to an increase in ambient air pollution above a baseline plus a specific increment allowed for one of three classes of areas. It is required for potential sources of air contaminants to register with the

260

TANGO ARRAY An Air Shower Experiment in Buenos Aires  

E-Print Network (OSTI)

A new Air Shower Observatory has been constructed in Buenos Aires during 1999, and commissioned and set in operation in 2000. The observatory consists of an array of four water \\v{C}erenkov detectors, enclosing a geometrical area of $\\sim$ 30.000 m$^{2}$, and is optimized for the observation of cosmic rays in the ``knee'' energy region. The array detects $\\sim$ 250 to $\\sim$ 1500 showers/day, depending on the selected triggering condition. In this paper, the design and construction of the array, and the automatic system for data adquisition, daily calibration, and monitoring, are described. Also, the Monte Carlo simulations performed to develop a shower database, as well as the studies performed using the database to estimate the response and the angular and energy resolutions of the array, are presented in detail.

P. Bauleo; C. Bonifazi; A. Filevich; A. Reguera

2001-04-20T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


261

Screw Air Compressor 220v, Screw Air Compressor 220v Suppliers ...  

U.S. Energy Information Administration (EIA)

Source Top Quality Screw Air Compressor 220v Suppliers, screw mini air compressor 220v Companies, atlas copco screw compressor Manufacturers. Welcome. ...

262

Simulation model air-to-air plate heat exchanger  

Science Conference Proceedings (OSTI)

A simple simulation model of an air-to-air plate heat exchanger is presented. The model belongs to a collection of simulation models that allows the eflcient computer simulation of heating, ventilation, and air-conditioning (HVAC) systems. The main emphasis of the models is to shorten computation time and to use only input data that are known in the design process of an HVAC system. The target of the models is to describe the behavior of HVAC components in the part-load operation mode, which is becoming increasingly important in energy eficient HVAC systems. The models are intended to be used for yearly energy calculations or load calculations with time steps of about 10 minutes or larger. Short- time dynamic effects, which are of interest for different aspects of control theory, are neglected. The part-load behavior is expressed in terms of the nominal condition and the dimensionless variation of the heat transfer with change of mass flow and temperature. The effectiveness- NTU relations are used to parametrize the convective heat transfer at nominal conditions and to compute the part-load condition. If the heat transfer coefficients on the two exchanger sides are not equal (i. e. due to partial bypassing of air), their ratio can be easily calculated and set as a parameter. The model is static and uses explicit equations only. The explicit model formulation ensures short computation time and numerical stability, which allows using the model with sophisticated engineering methods like automatic system optimization. This paper fully outlines the algorithm description and its simplifications. It is not tailored for any particular simulation program to ensure easy implementation in any simulation program.

Wetter, Michael

1999-01-01T23:59:59.000Z

263

Air sampling in the workplace. Final report  

Science Conference Proceedings (OSTI)

This report provides technical information on air sampling that will be useful for facilities following the recommendations in the NRC`s Regulatory Guide 8.25, Revision 1, ``Air sampling in the Workplace.`` That guide addresses air sampling to meet the requirements in NRC`s regulations on radiation protection, 10 CFR Part 20. This report describes how to determine the need for air sampling based on the amount of material in process modified by the type of material, release potential, and confinement of the material. The purposes of air sampling and how the purposes affect the types of air sampling provided are discussed. The report discusses how to locate air samplers to accurately determine the concentrations of airborne radioactive materials that workers will be exposed to. The need for and the methods of performing airflow pattern studies to improve the accuracy of air sampling results are included. The report presents and gives examples of several techniques that can be used to evaluate whether the airborne concentrations of material are representative of the air inhaled by workers. Methods to adjust derived air concentrations for particle size are described. Methods to calibrate for volume of air sampled and estimate the uncertainty in the volume of air sampled are described. Statistical tests for determining minimum detectable concentrations are presented. How to perform an annual evaluation of the adequacy of the air sampling is also discussed.

Hickey, E.E.; Stoetzel, G.A.; Strom, D.J.; Cicotte, G.R. [Pacific Northwest Lab., Richland, WA (United States); Wiblin, C.M. [Advanced Systems Technology, Inc., Atlanta, GA (United States); McGuire, S.A. [Nuclear Regulatory Commission, Washington, DC (United States). Div. of Regulatory Applications

1993-09-01T23:59:59.000Z

264

Air-Conditioning Basics | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Conditioning Basics Air-Conditioning Basics Air-Conditioning Basics August 16, 2013 - 1:59pm Addthis Air conditioning is one of the most common ways to cool homes and buildings. How Air Conditioners Work Air conditioners employ the same operating principles and basic components as refrigerators. Refrigerators use energy (usually electricity) to transfer heat from the cool interior of the refrigerator to the relatively warm surroundings; likewise, an air conditioner uses energy to transfer heat from the interior space to the relatively warm outside environment. An air conditioner uses a cold indoor coil called the evaporator. The condenser, a hot outdoor coil, releases the collected heat outside. The evaporator and condenser coils are serpentine tubing surrounded by aluminum fins. This tubing is usually made of copper.

265

Evolution of US air cargo productivity  

E-Print Network (OSTI)

This thesis provides an overview of the US air cargo industry since airline deregulation in 1978, including a brief overview of the historical evolution of air cargo transport in the US from the early 1900s until the late ...

Donatelli, David J

2012-01-01T23:59:59.000Z

266

Detecting Air Leaks | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Detecting Air Leaks Detecting Air Leaks Detecting Air Leaks September 27, 2012 - 6:39pm Addthis For a thorough and accurate measurement of air leakage in your home, hire a qualified technician to conduct an energy assessment, particularly a blower door test. For a thorough and accurate measurement of air leakage in your home, hire a qualified technician to conduct an energy assessment, particularly a blower door test. You may already know where some air leakage occurs in your home, such as an under-the-door draft, but you'll need to find the less obvious gaps to properly air seal your home. For a thorough and accurate measurement of air leakage in your home, hire a qualified technician to conduct an energy assessment, particularly a blower door test. A blower door test, which depressurizes a home, can

267

Improving Regional Air Quality with Wind Power  

Wind Powering America (EERE)

Improving Regional Air Quality with Improving Regional Air Quality with Wind Power National Renewable Energy Laboratory Improving Regional Air Quality with Wind Power National Renewable Energy Laboratory * Clean Air Act (CAA) framework * Air quality challenges * CAA policies as market drivers * Met. Wash. Council of Governments (MWCOG) case study * Environmental Protection Agency (EPA) guidance on State Implementation Plan (SIP) credit for EERE * Model SIP documentation for wind purchases * Related marketing innovations Overview Overview * CAA requires regional air quality plans (SIPs) * "Window of opportunity" - Revised SIPs required by 2006/2007 to meet new 8-hour ozone and PM standards - August 2004 EPA guidance and NREL model SIP documentation for wind purchases Clean Air Act Framework Clean Air Act Framework

268

Protective supplied-breathing-air garment  

DOE Patents (OSTI)

A breathing-air garment for isolating a wearer from hostile environments containing toxins or irritants is disclosed. The garment includes a suit and a separate head-protective enclosure or hood engaging a suit collar in sealing attachment. The hood and suit collar are cylindrically shaped and dimensioned to enable the wearer to withdraw his hands from the suit sleeves to perform manual tasks within the hood interior. Breathing air is supplied from an external air line with an air-delivery hose attached to the hood interior. The hose feeds air into an annular halo-like fiber-filled plenum having spaced discharge orifices attached to the hood top wall. A plurality of air exhaust/check valves located at the suit extremities cooperate with the hood air-delivery system to provide a cooling flow of circulating air from the hood throughout the suit interior. A suit entry seal provided on the suit sealed with an adhesive sealing flap.

Childers, E.L.; von Hortenau, E.F.

1982-05-28T23:59:59.000Z

269

Duct/Air sealing | Open Energy Information  

Open Energy Info (EERE)

Community Login | Sign Up Search Page Edit History Facebook icon Twitter icon DuctAir sealing Jump to: navigation, search TODO: Add description List of DuctAir sealing...

270

Catalysts for Destruction of Air Pollutants  

NLE Websites -- All DOE Office Websites (Extended Search)

Destruction of Air Pollutants Catalysts for Destruction of Air Pollutants U.S. industries and the U.S. Department of Energy must manage a variety of off-gas wastes consisting of...

271

Air Pollution Control Rules (West Virginia)  

Energy.gov (U.S. Department of Energy (DOE))

The listed rules were enacted as directed by the Air Pollution Control Act. Together, these rules guide the monitoring, permitting and compliance enforcement of air quality in the state.

272

Quantifying Precipitation Suppression Due to Air Pollution  

Science Conference Proceedings (OSTI)

Urban air pollution and industrial air pollution have been shown qualitatively to suppress rain and snow. Here, precipitation losses over topographical barriers downwind of major coastal urban areas in California and in the land of Israel that ...

Amir Givati; Daniel Rosenfeld

2004-07-01T23:59:59.000Z

273

Room Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

you need to mount the air conditioner at the narrow end of a long room, then look for a fan control known as "Power Thrust" or "Super Thrust" that sends the cooled air farther...

274

Seneca Compressed Air Energy Storage (CAES) Project  

DOE Green Energy (OSTI)

This document provides specifications for the process air compressor for a compressed air storage project, requests a budgetary quote, and provides supporting information, including compressor data, site specific data, water analysis, and Seneca CAES value drivers.

None

2012-11-30T23:59:59.000Z

275

Ambient Air Quality Criteria (Manitoba, Canada)  

Energy.gov (U.S. Department of Energy (DOE))

The Manitoba Ambient Air Quality Criteria schedule lists maximum time-based pollutant concentration levels for the protection and preservation of ambient air quality within the Province of Manitoba...

276

NETL: Air Quality III Conference  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Quality III Conference - September 12, 2002 Air Quality III Conference - September 12, 2002 Table of Contents Disclaimer Papers and Presentations Disclaimer This report was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government or any agency thereof, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof.

277

Airvest's Breath of Fresh Air  

NLE Websites -- All DOE Office Websites (Extended Search)

7 7 The Cutting Edge: Airvest's Breath of Fresh Air Spray booths are a common sight in the industrial sector. Designed to remove pollutants during industrial processes such as spray painting or welding, a booth is a rectangular enclosure open on one side where the worker stands, and equipped on the opposite wall with a fan and filter arrangement to suck away the dirty air. The full-size mannequin in these photographs simulates a worker in a spray booth facing the exhaust filters. In experiments designed by LBL researcher Ashok Gadgil, smoke was released in front of the mannequin to simulate the spraying of paint in the booth. The photo on the left shows the spray booth during standard operation. The smoke-representing a pollutant-is entrained in the eddy that forms in

278

Capturing Carbon Dioxide From Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Capturing Carbon Dioxide From Air Capturing Carbon Dioxide From Air Klaus S. Lackner (kl2010@columbia.edu; 212-854-0304) Columbia University 500 West 120th Street New York, NY 10027 Patrick Grimes (pgrimes@worldnet.att.net; 908-232-1134) Grimes Associates Scotch Plains, NJ 07076 Hans-J. Ziock (ziock@lanl.gov; 505-667-7265) Los Alamos National Laboratory P.O.Box 1663 Los Alamos, NM 87544 Abstract The goal of carbon sequestration is to take CO 2 that would otherwise accumulate in the atmosphere and put it in safe and permanent storage. Most proposed methods would capture CO 2 from concentrated sources like power plants. Indeed, on-site capture is the most sensible approach for large sources and initially offers the most cost-effective avenue to sequestration. For distributed, mobile sources like cars, on-board capture at affordable cost would not be

279

Clean Air Act, Section 309  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

CLEAN AIR ACT § 309* CLEAN AIR ACT § 309* §7609. Policy review (a) The Administrator shall review and comment in writing on the environmental impact of any matter relating to duties and responsibilities granted pursuant to this chapter or other provisions of the authority of Administrator, contained in any (1) legislation proposed by any Federal department or agency, (2) newly authorized Federal projects for construction and any major Federal agency action (other than a project for construction) to which section 4332(2)(C) of this title applies, and (3) proposed regulations published by any department or agency of the Federal Government. Such written comment shall be made public at the conclusion of any such review. (b) In the event the Administrator determines that any such legislation, action, or regulation

280

Air pollution and lung cancer  

SciTech Connect

Epidemiological evidence proves conclusively that lung cancer correlates with air pollution. However, data on lung cancer death rates and smoking show that mankind accepts the risk of long-term and low-level exposure to carcinogens. As a rule, immediate benefits are sought and remote hazards ignored. Fear of atmospheric contamination by radioactive fallout seems to be the main factor for awareness of air pollution. Experimental works help us to understand physics of particle deposition in the lungs (inertial impactation, sedimentation, Brownian movement), shed light on carcinogenesis (eg, bay region theory in case of polycyclic aromatic hydrocarbons and surface charge changes regarding asbestos), show that atmospheric particulates accepted as harmless may act as co-carcinogens (eg, iron and benzo(a)pyrene) and stress the importance of in vitro research (bacterial mutation tests, organ cultures, sister chromatid exchange system) to screen pollutants for their malignant potential and study their pathogenesis.

Boehm, G.M.

1982-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


281

Compressed Air Audits using AIRMaster  

E-Print Network (OSTI)

Air compressors are a significant industrial energy user and therefore a prime target for industrial energy audits. The project goal was to develop a software tool, AIRMaster, and supporting methodology for performing compressed air system audits. Seven field audits were conducted to refine the software and methodology as well as assess the savings potential of six common Operation and Maintenance measures. Audit results yielded significant savings with short payback periods. Total estimated savings for the project were 4,056,000 kWh or 49.2% of annual compressor energy for a cost savings of $152,000. Total implementation costs were $94,700 for a project payback period of 0.6 years. Capital benefits of delaying or avoiding the cost of a new compressor might double the energy benefits if a new compressor is being considered. The methodology proved to be a simple and effective audit tool.

Wheeler, G. M.; McGill, R. D.; Bessey, E. G.; Vischer, K.

1997-04-01T23:59:59.000Z

282

Air Conditioner Compressor Performance Model  

SciTech Connect

During the past three years, the Western Electricity Coordinating Council (WECC) Load Modeling Task Force (LMTF) has led the effort to develop the new modeling approach. As part of this effort, the Bonneville Power Administration (BPA), Southern California Edison (SCE), and Electric Power Research Institute (EPRI) Solutions tested 27 residential air-conditioning units to assess their response to delayed voltage recovery transients. After completing these tests, different modeling approaches were proposed, among them a performance modeling approach that proved to be one of the three favored for its simplicity and ability to recreate different SVR events satisfactorily. Funded by the California Energy Commission (CEC) under its load modeling project, researchers at Pacific Northwest National Laboratory (PNNL) led the follow-on task to analyze the motor testing data to derive the parameters needed to develop a performance models for the single-phase air-conditioning (SPAC) unit. To derive the performance model, PNNL researchers first used the motor voltage and frequency ramping test data to obtain the real (P) and reactive (Q) power versus voltage (V) and frequency (f) curves. Then, curve fitting was used to develop the P-V, Q-V, P-f, and Q-f relationships for motor running and stalling states. The resulting performance model ignores the dynamic response of the air-conditioning motor. Because the inertia of the air-conditioning motor is very small (H<0.05), the motor reaches from one steady state to another in a few cycles. So, the performance model is a fair representation of the motor behaviors in both running and stalling states.

Lu, Ning; Xie, YuLong; Huang, Zhenyu

2008-09-05T23:59:59.000Z

283

Residential Indoor Air Background Data  

Science Conference Proceedings (OSTI)

Soil vapor intrusion, the migration of volatile chemicals from contaminated soil or groundwater into overlying buildings, has become one of the primary exposure pathways of concern for state and federal environmental agencies regulating contaminated sites in the USA. Regulators are requesting comprehensive evaluation of the subsurface vapor-to-indoor air pathway for currently occupied buildings, areas which may be developed in the future, and closed sites for which this pathway was not previously evaluat...

2007-03-16T23:59:59.000Z

284

Clean Air Act. Revision 5  

SciTech Connect

This Reference Book contains a current copy of the Clean Air Act, as amended, and those regulations that implement the statute and appear to be most relevant to DOE activities. The document is provided to DOE and contractor staff for informational purposes only and should not be interpreted as legal guidance. This Reference Book has been completely revised and is current through February 15, 1994.

Not Available

1994-02-15T23:59:59.000Z

285

ARM - Campaign Instrument - dri-air  

NLE Websites -- All DOE Office Websites (Extended Search)

Send Campaign Instrument : Desert Research Institute Airborne Aerosol Instruments (DRI-AIR) Instrument Categories Aerosols, Airborne Observations Campaigns Aerosol IOP ...

286

South Coast Air Quality Management District  

Science Conference Proceedings (OSTI)

South Coast Air Quality Management District. NVLAP Lab Code: 101567-0. Address and Contact Information: 21865 Copley ...

2013-08-09T23:59:59.000Z

287

Do filters pollute the air? Part 1  

E-Print Network (OSTI)

Air Infiltration Glossary-Italian Edition. TechnicalNote AIC 5.3]. Glossary-Italian Edition. Technical Note AIC

Bek, Gabriel; Schiavon, Stefano

2008-01-01T23:59:59.000Z

288

AIR LEAKAGE OF NEWLY INSTALLED RESIDENTIAL WINDOWS  

E-Print Network (OSTI)

Through Sash/Frame Cracks . Window Operation Types . . . . .Window Operation Types . . . . .Air Leakage of Installed Windows Scattergram of Field

Weidt, John

2013-01-01T23:59:59.000Z

289

Hybrid regional air pollution models  

SciTech Connect

This discussion deals with a family of air quality models for predicting and analyzing the fine particulate loading in the atmosphere, for assessing the extent and degree of visibility impairment, and for determining the potential of pollutants for increasing the acidity of soils and water. The major horizontal scales of interest are from 400km to 2000km; and the time scales may vary from several hours, to days, weeks, and a few months or years, depending on the EPA regulations being addressed. First the role air quality models play in the general family of atmospheric simulation models is described. Then, the characteristics of a well-designed, comprehensive air quality model are discussed. Following this, the specific objectives of this workshop are outlined, and their modeling implications are summarized. There are significant modeling differences produced by the choice of the coordinate system, whether it be the fixed Eulerian system, the moving Lagrangian system, or some hybrid of the two. These three systems are briefly discussed, and a list of hybrid models that are currently in use are given. Finally, the PNL regional transport model is outlined and a number of research needs are listed.

Drake, R.L.

1980-03-01T23:59:59.000Z

290

Zoned heating and air conditioning system  

SciTech Connect

This patent describes a zoned heating and air conditioning system comprising: a central air handling system with an air heating means and an air cooling means and a blower connected to an air duct system; thermostats each have heating and cooling set points, respectively associated with and located in different zones of a building; dampers respectively associated with each building zone positioned in the air duct system. Each damper has an open position allowing air into the respective zone from the duct system and a closed position; relay means for connecting one thermostat to the air handling system upon a call for heating or cooling by one thermostat and disconnecting all other thermostats by connecting one thermostat's connections between the thermostat and air handling system. Only one thermostat is connected to the air handling system at a time and the relay means disconnects one thermostat from the air handling system after one thermostat is satisified; and damper actuating means for unlocking each damper in one building zone responsive actuated by a respective zone thermostat connected to the air handling system by the relay means. The damper actuates means including a damper solenoid for each damper located adjacent each damper and connected to a respective zone thermostat. It unlocks each damper in one building zone responsive to being actuated by the respective zone thermostat and unlocks the dampers in one building zone when one thermostat is actuated while preventing the dampers in another thermostat's building zone from unlocking.

Beachboard, S.A.

1987-06-16T23:59:59.000Z

291

Strategy Guideline: Compact Air Distribution Systems  

SciTech Connect

This Strategy Guideline discusses the benefits and challenges of using a compact air distribution system to handle the reduced loads and reduced air volume needed to condition the space within an energy efficient home. Traditional systems sized by 'rule of thumb' (i.e., 1 ton of cooling per 400 ft2 of floor space) that 'wash' the exterior walls with conditioned air from floor registers cannot provide appropriate air mixing and moisture removal in low-load homes. A compact air distribution system locates the HVAC equipment centrally with shorter ducts run to interior walls, and ceiling supply outlets throw the air toward the exterior walls along the ceiling plane; alternatively, high sidewall supply outlets throw the air toward the exterior walls. Potential drawbacks include resistance from installing contractors or code officials who are unfamiliar with compact air distribution systems, as well as a lack of availability of low-cost high sidewall or ceiling supply outlets to meet the low air volumes with good throw characteristics. The decision criteria for a compact air distribution system must be determined early in the whole-house design process, considering both supply and return air design. However, careful installation of a compact air distribution system can result in lower material costs from smaller equipment, shorter duct runs, and fewer outlets; increased installation efficiencies, including ease of fitting the system into conditioned space; lower loads on a better balanced HVAC system, and overall improved energy efficiency of the home.

Burdick, A.

2013-06-01T23:59:59.000Z

292

Intelligent pairing assistant for air operation centers  

Science Conference Proceedings (OSTI)

Within an Air Operations Center (AOC), planners make crucial decisions to create the air plan for any given day. They are expected to complete the plan in part by pairing targeting or collection tasks with the available platforms. Any assistance these ... Keywords: air operations center, intelligent user interface, pairing, reinforcement learning

Jeremy Ludwig; Eric Geiselman

2012-02-01T23:59:59.000Z

293

Air breathing direct methanol fuel cell  

DOE Patents (OSTI)

An air breathing direct methanol fuel cell is provided with a membrane electrode assembly, a conductive anode assembly that is permeable to air and directly open to atmospheric air, and a conductive cathode assembly that is permeable to methanol and directly contacting a liquid methanol source.

Ren, Xiaoming (Los Alamos, NM)

2002-01-01T23:59:59.000Z

294

Workshop on indoor air quality research needs  

Science Conference Proceedings (OSTI)

Workshop participants report on indoor air quality research needs including the monitoring of indoor air quality, report of the instrumentation subgroup of indoor air quality, health effects, and the report of the control technology session. Risk analysis studies addressing indoor environments were also summarized. (DLS)

Not Available

1980-01-01T23:59:59.000Z

295

Commercial thermal distribution systems, Final report for CIEE/CEC  

E-Print Network (OSTI)

Design." Atlanta, American Society of Heating, Refrigeration, andRefrigeration, and Air Conditioning Engineers Brake horsepower Building Management System Constant air volume Center for Environmental Design

Xu, T.

2011-01-01T23:59:59.000Z

296

Analysis of U.S. residential air leakage database  

E-Print Network (OSTI)

installing air and vapor barriers, and sealing ducts.that will reduce air in?ltration such as sealing air leaks,

Chan, Wanyu R.; Price, Phillip N.; Sohn, Michael D.; Gadgil, Ashok J.

2003-01-01T23:59:59.000Z

297

Fact Sheet: Isothermal Compressed Air Energy Storage (October...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Isothermal Compressed Air Energy Storage (October 2012) Fact Sheet: Isothermal Compressed Air Energy Storage (October 2012) SustainX will demonstrate an isothermal compressed air...

298

Investigation of residential central air conditioning load shapes in NEMS  

E-Print Network (OSTI)

of Residential Central Air Conditioning Load Shapes in NEMSof Residential Central Air Conditioning Load Shapes in NEMSof Residential Central Air Conditioning Load Shapes in NEMS

Hamachi LaCommare, Kristina; Marnay, Chris; Gumerman, Etan; Chan, Peter; Rosenquist, Greg; Osborn, Julie

2002-01-01T23:59:59.000Z

299

Performance of underfloor air distribution: Results of a field study  

E-Print Network (OSTI)

Refrigerating, and Air Conditioning Engineers. AtlantaRefrigerating, and Air Conditioning Engineers. AtlantaRefrigerating, and Air-Conditioning Engineers, Inc. ,

Fisk, William; Faulkner, David; Sullivan, Douglas

2004-01-01T23:59:59.000Z

300

Air Products Hydrogen Energy Systems | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Products Hydrogen Energy Systems Air Products Hydrogen Energy Systems Hydrogen Infrastructure Air Products Hydrogen Energy Systems More Documents & Publications Quadrennial...

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


301

Shale Gas Development Challenges: Air | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Shale Gas Development Challenges: Air Shale Gas Development Challenges: Air Shale Gas Development Challenges: Air More Documents & Publications Natural Gas from Shale: Questions...

302

buy Adekom VSD Air Compressor - high quality Manufacturers ...  

U.S. Energy Information Administration (EIA)

Adekom VSD Air Compressor trade offers directory and Adekom VSD Air Compressor business offers list. Trade leads from Adekom VSD Air Compressor ...

303

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers Title Air Corrosivity in U.S. Outdoor-Air-Cooled Data Centers is Similar to That in Conventional Data Centers Publication Type Report LBNL Report Number LBNL-4951E Year of Publication 2011 Authors Coles, Henry C., Tae Won Han, Phillip N. Price, Ashok J. Gadgil, and William F. Tschudi Date Published 03/2011 Abstract There is a concern that environmental-contamination caused corrosion may negatively affect Information Technology (IT) equipment reliability. Nineteen data centers in the United States and two in India were evaluated using Corrosion Classification Coupons (CCC) to assess environmental air quality as it may relate IT equipment reliability. The data centers were of two basic types: "closed" and outside-air cooled. A closed data center provides cool air to the IT equipment using air conditioning in which only a small percentage of the recirculation air is "make-up" air continuously supplied from outside to meet human health requirements. An outside-air cooled data center uses outside air directly as the primary source for IT equipment cooling. Corrosion measuring coupons containing copper and silver metal strips were placed in both "closed" and outside-air cooled data centers. The coupons were placed at each data center (closed and outside-air cooled types) with the location categorized into three groups:

304

Laboratory Study of Premixed H2-Air and H2-N2-Air Flames in a...  

NLE Websites -- All DOE Office Websites (Extended Search)

of Premixed H2-Air and H2-N2-Air Flames in a Low-Swirl Injector for Ultra-Low Emissions Gas Turbines Title Laboratory Study of Premixed H2-Air and H2-N2-Air Flames in a Low-Swirl...

305

Sensitivity of forced air distribution system efficiency to climate, duct location, air leakage and insulation  

E-Print Network (OSTI)

Location, Air Leakage and Insulation Iain S. Walker Energy4 Duct Insulation, Location and Leakageinsulation

Walker, Iain

2001-01-01T23:59:59.000Z

306

Analysis of a Dedicated Outdoor Air System and Low Temperature Supply Air Conditioning System  

E-Print Network (OSTI)

This paper presents the principles and the characteristics of a dedicated outdoor air system (DOAS) and low temperature supply air system. DOAS is offered based on the demands of indoor air quality and the low temperature supply air system is offered based on the demands of saving energy. The two systems are very similar, which is analyzed in this paper. Using actual engineering, we compute the air flow rate, cold load and energy consumption in detail, and provide some good conclusions.

Guang, L.; Li, R.

2006-01-01T23:59:59.000Z

307

Clean Air Act | Open Energy Information  

Open Energy Info (EERE)

Clean Air Act Clean Air Act Jump to: navigation, search Statute Name Clean Air Act Year 1970 Url CAA.jpg Description Congress passed the CAA in 1970 in order to combat air pollution in the United States and protect the health and general welfare of United States citizens against air pollutants. References CAA[1] Federal Oil and Gas[2] Contents 1 Introduction 2 Title I Air Pollution Prevention 3 Title II Emission Standards for Moving Sources 4 Title III General Provisions 5 Title IV Acid Deposition Control 6 Title V Permits 7 Title VI Stratospheric Ozone Protection 8 References Introduction The Clean Air Act was enacted by congress in 1990. Since then only minor changes have been made. The act is just a law ensuring that the EPA will follow certain guidelines and definitions for protecting and improving the

308

Air Sealing Your Home | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Your Home Your Home Air Sealing Your Home November 26, 2013 - 6:22pm Addthis Save on heating and cooling costs by checking for air leaks in common trouble spots in your home. Save on heating and cooling costs by checking for air leaks in common trouble spots in your home. What does this mean for me? Save money and energy by air sealing your house. Caulking and weatherstripping are simple, effective ways of sealing air leaks in your home. Reducing the amount of air that leaks in and out of your home is a cost-effective way to cut heating and cooling costs, improve durability, increase comfort, and create a healthier indoor environment. Caulking and weatherstripping are two simple and effective air-sealing techniques that offer quick returns on investment, often one year or less. Caulk is

309

Air Products Chemicals Inc | Open Energy Information  

Open Energy Info (EERE)

Air Products Chemicals Inc Air Products Chemicals Inc Jump to: navigation, search Name Air Products & Chemicals Inc Place Allentown, Pennsylvania Zip 18195 Sector Hydro, Hydrogen, Services Product A global supplier of merchant hydrogen with a portfolio of products, services and solutions providing gases, performance materials and chemical intermediates. References Air Products & Chemicals Inc[1] LinkedIn Connections CrunchBase Profile No CrunchBase profile. Create one now! This article is a stub. You can help OpenEI by expanding it. Air Products & Chemicals Inc is a company located in Allentown, Pennsylvania . References ↑ "Air Products & Chemicals Inc" Retrieved from "http://en.openei.org/w/index.php?title=Air_Products_Chemicals_Inc&oldid=341937

310

Tips: Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Air Conditioners Tips: Air Conditioners Tips: Air Conditioners June 24, 2013 - 6:31pm Addthis Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Buying a bigger room air conditioner won't necessarily make you feel more comfortable during the hot summer months. In fact, a room air conditioner that's too big for the area it is supposed to cool will perform less efficiently and less effectively than a smaller, properly sized unit. The reason: an oversized unit will cool the room(s) to the thermostat set-point before proper dehumidification occurs, making the area feel "clammy"

311

Alpha-environmental continuous air monitor inlet  

DOE Patents (OSTI)

A wind deceleration and protective shroud that provides representative samples of ambient aerosols to an environmental continuous air monitor (ECAM) has a cylindrical enclosure mounted to an input on the continuous air monitor, the cylindrical enclosure having shrouded nozzles located radially about its periphery. Ambient air flows, often along with rainwater flows into the nozzles in a sampling flow generated by a pump in the continuous air monitor. The sampling flow of air creates a cyclonic flow in the enclosure that flows up through the cylindrical enclosure until the flow of air reaches the top of the cylindrical enclosure and then is directed downward to the continuous air monitor. A sloped platform located inside the cylindrical enclosure supports the nozzles and causes any moisture entering through the nozzle to drain out through the nozzles.

Rodgers, John C. (Santa Fe, NM)

2003-01-01T23:59:59.000Z

312

Industrial Compressed Air System Energy Efficiency Guidebook.  

DOE Green Energy (OSTI)

Energy efficient design, operation and maintenance of compressed air systems in industrial plants can provide substantial reductions in electric power and other operational costs. This guidebook will help identify cost effective, energy efficiency opportunities in compressed air system design, re-design, operation and maintenance. The guidebook provides: (1) a broad overview of industrial compressed air systems, (2) methods for estimating compressed air consumption and projected air savings, (3) a description of applicable, generic energy conservation measures, and, (4) a review of some compressed air system demonstration projects that have taken place over the last two years. The primary audience for this guidebook includes plant maintenance supervisors, plant engineers, plant managers and others interested in energy management of industrial compressed air systems.

United States. Bonneville Power Administration.

1993-12-01T23:59:59.000Z

313

Tips: Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Tips: Air Conditioners Tips: Air Conditioners Tips: Air Conditioners June 24, 2013 - 6:31pm Addthis Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Bigger isn't always better for an air conditioner. Learn effective ways to stay cool while saving energy. | Photo courtesy of ©iStockphoto/galinast. Buying a bigger room air conditioner won't necessarily make you feel more comfortable during the hot summer months. In fact, a room air conditioner that's too big for the area it is supposed to cool will perform less efficiently and less effectively than a smaller, properly sized unit. The reason: an oversized unit will cool the room(s) to the thermostat set-point before proper dehumidification occurs, making the area feel "clammy"

314

Air-Con International: Noncompliance Determination and Proposed...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

to Air-Con International finding that a variety of central air conditioners and air conditioning heat pumps distributed under the Air-Con private label do not comport...

315

Air-Source Heat Pumps | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Source Heat Pumps Air-Source Heat Pumps August 19, 2013 - 11:03am Addthis Air-source heat pumps transfer heat between the inside of a building and the outside air. How...

316

Numerical Analysis of a Cold Air Distribution System  

E-Print Network (OSTI)

Cold air distribution systems may reduce the operating energy consumption of air-conditioned air supply system and improve the outside air volume percentages and indoor air quality. However, indoor temperature patterns and velocity field are easily non-uniform so that residents usually feel uncomfortable. The distribution of indoor airflow by cold air distribution is researched in this paper. We study indoor air distribution under different low temperature air supply conditions by numerical simulation. The simulated results agree well with the experiments.

Zhu, L.; Li, R.; Yuan, D.

2006-01-01T23:59:59.000Z

317

Air Force Announces Funding for Alternative Energy Research ...  

Air Force Announces Funding for Alternative Energy Research & Development. December 16, 2013. The Air Force Research Laboratory (AFRL) has ...

318

Night air cargo operations flyover noise mitigation by a municipality  

Science Conference Proceedings (OSTI)

A 1981 Air Force Draft Environmental ImpactAnalysis (DEIA) on converting Rickenbacker Air National Guard Base (RANGB

Angelo J. Campanella

1985-01-01T23:59:59.000Z

319

Air and water cooled modulator  

DOE Patents (OSTI)

A compact high power magnetic compression apparatus and method are disclosed for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air. 9 figs.

Birx, D.L.; Arnold, P.A.; Ball, D.G.; Cook, E.G.

1995-09-05T23:59:59.000Z

320

Air and water cooled modulator  

DOE Patents (OSTI)

A compact high power magnetic compression apparatus and method for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air.

Birx, Daniel L. (Oakley, CA); Arnold, Phillip A. (Livermore, CA); Ball, Don G. (Livermore, CA); Cook, Edward G. (Livermore, CA)

1995-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


321

Air Force Enhanced Use Lease  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

1 1 Air Force Enhanced Use Lease Mr. Brian Brown 16 Oct. 12 I n t e g r i t y - S e r v i c e - E x c e l l e n c e 2 Agenda  Brian Brown  Enhanced Use Lease (EUL) Overview  Energy EULs  EUL Goals  David Swanson  Energy EUL Market Drivers  Current EUL Projects  Partnering with the Air Force  Contact Information I n t e g r i t y - S e r v i c e - E x c e l l e n c e 3 Overview  Authority 10 USC 2667  An EUL is a lease  By the government  Of "non-excess" property  Under the control of the government  To a public or private sector lessee  In exchange for fair market value rental payments in cash and/or in kind consideration I n t e g r i t y - S e r v i c e - E x c e l l e n c e

322

Ambient Operation of Li/Air Batteries  

Science Conference Proceedings (OSTI)

In this work, Li/air batteries based on nonaqueous electrolytes were investigated in ambient conditions (with an oxygen partial pressure of 0.21 atm and relative humidity of ~20%). A heat-sealable polymer membrane was used as both an oxygen-diffusion membrane and as a moisture barrier for Li/air batteries. The membrane also can minimize the evaporation of the electrolyte from the batteries. Li/air batteries with this membrane can operate in ambient conditions for more than one month with a specific energy of 362 Wh kg-1, based on the total weight of the battery including its packaging. Among various carbon sources used in this work, Li/air batteries using Ketjenblack (KB) carbon-based air electrodes exhibited the highest specific energy. However, KB-based air electrodes expanded significantly and absorbed much more electrolyte than electrodes made from other carbon sources. The weight distribution of a typical Li/air battery using the KB-based air electrode was dominated by the electrolyte (~70%). Lithium-metal anodes and KB-carbon anodes account for only 5.12% and 5.78% of the battery weight, respectively. We also found that only ~ 20% of the mesopore volume of the air electrode was occupied by reaction products after discharge. To further improve the specific energy of the Li/air batteries, the microstructure of the carbon electrode needs to be further improved to absorb much less electrolyte while still holding significant amounts of reaction products

Zhang, Jiguang; Wang, Deyu; Xu, Wu; Xiao, Jie; Williford, Ralph E.

2010-07-01T23:59:59.000Z

323

Improving air handler efficiency in houses  

SciTech Connect

Although furnaces, air conditioners and heat pumps have become significantly more efficient over the last couple of decades, residential air handlers have typical efficiencies of only 10% to 15% due to poor electric motor performance and aerodynamically poor fans and fan housings. Substantial increases in performance could be obtained through improved air handler design and construction. A prototype residential air handler intended to address these issues has recently been developed. The prototype and a standard production fan were tested in a full-scale duct system and test chamber at LBNL specifically designed for testing heating, ventilation, and air conditioning systems. The laboratory tests compared efficiency, total airflow, sensitivity to duct system flow resistance, and the effects of installation in a smaller cabinet. The test results showed that the prototype air handler had about twice the efficiency of the standard air handler (averaged over a wide range of operating conditions) and was less sensitive to duct system flow resistance changes. The performance of both air handlers was significantly reduced by reducing the clearance between the air handler and cabinet it was placed in. These test results showed that in addition to the large scope for performance improvement, air handler fans need to be tested in the cabinets they operate in.

Walker, Iain S.

2004-05-01T23:59:59.000Z

324

DOE Requires Air-Con International to Cease Sales of Inefficient Air  

NLE Websites -- All DOE Office Websites (Extended Search)

Requires Air-Con International to Cease Sales of Inefficient Requires Air-Con International to Cease Sales of Inefficient Air Conditioners and Proposes Penalties DOE Requires Air-Con International to Cease Sales of Inefficient Air Conditioners and Proposes Penalties September 21, 2010 - 6:43pm Addthis The Department has issued a Notice of Noncompliance Determination and Proposed Civil Penalty to Air-Con, International, requiring Air-Con to cease the sale of certain air-conditioning systems in the United States and proposing a civil penalty of $231,090 for sales of these products in violation of the applicable energy efficiency standards. This action reflects the Department's continued commitment to act aggressively to remove unlawful products from the market. In March, 2010, the Department issued a subpoena requiring Air-Con to

325

Lithium-Air Battery: High Performance Cathodes for Lithium-Air Batteries  

SciTech Connect

BEEST Project: Researchers at Missouri S&T are developing an affordable lithium-air (Li-Air) battery that could enable an EV to travel up to 350 miles on a single charge. Todays EVs run on Li-Ion batteries, which are expensive and suffer from low energy density compared with gasoline. This new Li-Air battery could perform as well as gasoline and store 3 times more energy than current Li-Ion batteries. A Li-Air battery uses an air cathode to breathe oxygen into the battery from the surrounding air, like a human lung. The oxygen and lithium react in the battery to produce electricity. Current Li-Air batteries are limited by the rate at which they can draw oxygen from the air. The team is designing a battery using hierarchical electrode structures to enhance air breathing and effective catalysts to accelerate electricity production.

2010-08-01T23:59:59.000Z

326

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Desiccant Enhanced Evaporative Air Conditioning Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system. DEVAP uses 90 percent less electricity and up to 80 percent less

327

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning Lab Breakthrough: Desiccant Enhanced Evaporative Air Conditioning May 29, 2012 - 5:22pm Addthis This breakthrough combines desiccant materials, which remove moisture from the air using heat, and advanced evaporative technologies to develop a cooling unit that uses 90 percent less electricity and up to 80 percent less total energy than traditional air conditioning. This solution, called the desiccant enhanced evaporative air conditioner (DEVAP), also controls humidity more effectively to improve the comfort of people in buildings. View the entire Lab Breakthrough playlist. What are the key facts? Recent materials advances and liquid desiccant advances to design the compact and cost-effective DEVAP system.

328

General Air Permits (Louisiana) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

General Air Permits (Louisiana) General Air Permits (Louisiana) General Air Permits (Louisiana) < Back Eligibility Agricultural Construction Industrial Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Louisiana Program Type Environmental Regulations Provider Louisiana Department of Environmental Quality Any source, including a temporary source, which emits or has the potential to emit any air contaminant requires an air permit. Facilities with potential emissions less than 5 tons per year of any regulated air pollutant do not need a permit. The Louisiana Department of Environmental Quality issues Title V General Permits. The permit is developed based on equipment types versus facility types, the general permits are not limited in their use to a specific industry or category. Title V permits combine

329

University of Colorado Indoor Air Quality Report  

NLE Websites -- All DOE Office Websites (Extended Search)

Image Courtesy of Ohio Image Courtesy of Ohio State University INDOOR AIR QUALITY Design Goals Design Goals Design Goals Design Goals Integrate technologically and economically innovative, low-energy strategies Minimize occupant distraction User-friendly controls Minimize pollutant sources Bio Bio Bio Bio- - - -S S S S ( ( ( (h h h h) ) ) ) ip ip ip ip indoor air quality features indoor air quality features indoor air quality features indoor air quality features Mechanical Systems Energy Recovery Ventilator Exhaust Fans Heating And Cooling Systems Passive Ventilation Low VOC materials Each of these features is described in more detail below. Mechanical Systems Energy Recovery Ventilator Knowing that our home has a tight envelope, due to our Bio-SIP construction, we needed to use mechanical ventilation to ensure suitable indoor air

330

NETL: IEP - Air Quality Research: Regulatory Drivers  

NLE Websites -- All DOE Office Websites (Extended Search)

Regulatory Drivers Regulatory Drivers DOE/NETL’s Air Quality Research Program is in direct response to the need to ensure that fossil-fuel-fired power systems continue to meet current and future environmental requirements. Specific environmental regulatory requirements driving this research are briefly summarized below: I. Clean Air Act (Including 1990 Amendments) Title I - Air Pollution Prevention and Control Part A - Air Quality and Emission Limitations Sect. 109 - National Ambient Air Quality Standards In July 1997 EPA promulgated new standards for particulate matter finer than 2.5 micrometers (PM2.5) and revised the ambient ozone standards. Sect. 111 - Standards of Performance for New Stationary Sources Part C - Prevention of Significant Deterioration of Air Quality

331

Stirling Air Conditioner for Compact Cooling  

Science Conference Proceedings (OSTI)

BEETIT Project: Infinia is developing a compact air conditioner that uses an unconventional high efficient Stirling cycle system (vs. conventional vapor compression systems) to produce cool air that is energy efficient and does not rely on polluting refrigerants. The Stirling cycle system is a type of air conditioning system that uses a motor with a piston to remove heat to the outside atmosphere using a gas refrigerant. To date, Stirling systems have been expensive and have not had the right kind of heat exchanger to help cool air efficiently. Infinia is using chip cooling technology from the computer industry to make improvements to the heat exchanger and improve system performance. Infinias air conditioner uses helium gas as refrigerant, an environmentally benign gas that does not react with other chemicals and does not burn. Infinias improvements to the Stirling cycle system will enable the cost-effective mass production of high-efficiency air conditioners that use no polluting refrigerants.

None

2010-09-01T23:59:59.000Z

332

Underbalanced drilling with air offers many pluses  

Science Conference Proceedings (OSTI)

A pressure overbalance during conventional drilling can cause significant fluid filtrate invasion and lost circulation. Fluid invasion into the formation can lead to formation damage, high mud costs, a need for expensive completions, and well productivity impairment. Because underbalanced drilling creates a natural tendency for fluid and gas to flow from the formation to the borehole, successful underbalanced drilling depends upon the appropriate selection of circulating fluid. The use of a compressible fluid in the circulating system, referred to as air drilling, lowers the downhole pressure, allowing drilling into and beyond these sensitive formations. The paper discusses the equipment needed; well control; downhole air requirements; air drilling techniques using dry air, air-mist, stable foam, stiff foam, and aerated-fluid; downhole fires; directional air drilling; and well completions.

Shale, L. [Baker Hughes Inteq, Houston, TX (United States)

1995-06-26T23:59:59.000Z

333

Room air monitor for radioactive aerosols  

DOE Patents (OSTI)

A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-pre The U.S. Government has rights in this invention pursuant to Contract No. DE-AC04-76DP03533 between the Department of Energy and Rockwell International Corporation.

Balmer, David K. (Broomfield, CO); Tyree, William H. (Boulder, CO)

1989-04-11T23:59:59.000Z

334

Room air monitor for radioactive aerosols  

DOE Patents (OSTI)

A housing assembly for use with a room air monitor for simultaneous collection and counting of suspended particles includes a casing containing a combination detector-preamplifier system at one end, a filter system at the other end, and an air flow system consisting of an air inlet formed in the casing between the detector-preamplifier system and the filter system and an air passageway extending from the air inlet through the casing and out the end opposite the detector-preamplifier combination. The filter system collects suspended particles transported directly through the housing by means of the air flow system, and these particles are detected and examined for radioactivity by the detector-preamplifier combination. 2 figs.

Balmer, D.K.; Tyree, W.H.

1987-03-23T23:59:59.000Z

335

Heating, Ventilation and Air Conditioning Efficiency  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Presented By: WALTER E. JOHNSTON, PE Presented By: WALTER E. JOHNSTON, PE CEM, CEA, CLEP, CDSM, CPE Air Conditioning (HVAC) system is to provide and maintain a comfortable environment within a building for the occupants or for the process being conducted Many HVAC systems were not designed with energy efficiency as one of the design factors 3 Air Air is the major conductor of heat. Lack of heat = air conditioning OR 4 Btu - Amount of heat required to raise one pound of water 1 F = 0.252 KgCal 1 Pound of Water = About 1 Pint of Water ~ 1 Large Glass 1 Kitchen Match Basics of Air Conditioning = 1 Btu 5 = 6 Low Cost Cooling Unit 7 8 Typical Design Conditions 75 degrees F temperature 50% relative humidity 30 - 50 FPM air movement

336

Evaporative Enhancement for Air Cooled Condensers  

Science Conference Proceedings (OSTI)

This report summarizes research into condenser air evaporative pre-cooling technologies and the associated potential for energy and peak power savings. The interest in this project is evaluation of the specific application of evaporative cooling to the inlet air of condenser coils, particularly for large roof-top type air cooled chillers. While the technology is established and understood particularly well for hot, dry climates, this report is intended to also examine evaporative ...

2013-03-06T23:59:59.000Z

337

Inlet Air Filtration Assessment: Interim Report  

Science Conference Proceedings (OSTI)

The goal of inlet air filtration is to capture the largest amount of particulate (solid or liquid) by filter media in the airflow path of the gas turbine. With engines operating at higher temperatures and with downstream components that are more susceptible to problems associated with harmful effects such as fouling, erosion, and corrosion, the need for good inlet air filtration in this newest generation of gas turbines is more important than ever. Recent advances in inlet air filtration have ...

2013-12-19T23:59:59.000Z

338

Air Products Hydrogen Energy Systems  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Kiczek,Edward F. [KICZEKEF@airproducts.com] Kiczek,Edward F. [KICZEKEF@airproducts.com] Sent: Monday, April 18, 2011 7:40 PM To: Gopstein, Avi (S4) Subject: Hydrogen Infrastructure Latest Advancements Attachments: Air Products Written Comments to 2011 2012 AB118 Investment Plan.pdf Follow Up Flag: Follow up Flag Status: Flagged Categories: QTR Transparency Avi, You may recall we met in DC when the McKinsey team from Germany came to discuss the EU study on hydrogen infrastructure. At that time I mention a significant advance in infrastructure that would be announced soon. Attached is our testimony to the California Energy Commission on deploying that technology. We were awarded the project to build 9 stations in southern California with the backing of

339

Enclosed rotary disc air pulser  

DOE Patents (OSTI)

An enclosed rotary disc air pulser for use with a solvent extraction pulse olumn includes a housing having inlet, exhaust and pulse leg ports, a shaft mounted in the housing and adapted for axial rotation therein, first and second disc members secured to the shaft within the housing in spaced relation to each other to define a chamber therebetween, the chamber being in communication with the pulse leg port, the first disc member located adjacent the inlet port, the second disc member being located adjacent the exhaust port, each disc member having a milled out portion, the disc members positioned on the shaft so that as the shaft rotates, the milled out portions permit alternative cyclical communication between the inlet port and the chamber and the exhaust port and the chamber.

Olson, A. L. (Idaho Falls, ID); Batcheller, Tom A. (Idaho Falls, ID); Rindfleisch, J. A. (Arco, ID); Morgan, John M. (Arco, ID)

1989-01-01T23:59:59.000Z

340

Enclosed rotary disc air pulser  

DOE Patents (OSTI)

This invention is comprised of an enclosed rotary disc air pulser for use with a solvent extraction pulse column includes a housing having inlet, exhaust and pulse leg ports, a shaft mounted in the housing and adapted for axial rotation therein, first and second disc members secured to the shaft within the housing in spaced relation to each other to define a chamber there between, the chamber being in communication with the pulse leg port, and first disc member located adjacent the inlet port, the second disc member being located adjacent the exhaust port, each disc member having a milled out portion, the disc members positioned on the shaft so that as the shaft rotates, the milled out portions permit alternative cyclical communication between the inlet port and the chamber and the exhaust port and chamber. 5 figs.

Olson, A.L.; Batcheller, T.A.; Rindfleisch, J.A.; Morgan, J.M.

1988-08-12T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


341

Ambient Air Quality Standards (New Jersey)  

Energy.gov (U.S. Department of Energy (DOE))

This article lists specific standards for ambient air quality standards for particulate matter, sulfur dioxide, carbon monoxide, ozone, lead and nitrogen dioxide.

342

Energy efficiency and air regulation | ENERGY STAR  

NLE Websites -- All DOE Office Websites (Extended Search)

EPA boiler rules New EPA regulations for industrial, commercial, and institutional boilers encourage energy efficiency measures to help reduce hazardous air pollutants. Energy...

343

Energy Basics: Air-Source Heat Pumps  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

Systems Air-Source Heat Pumps Ductless Mini-Split Heat Pumps Absorption Heat Pumps Geothermal Heat Pumps Supporting Equipment for Heating & Cooling Systems Water Heating...

344

Air Pollution Control (Indiana) | Open Energy Information  

Open Energy Info (EERE)

StateProvince Program Administrator Air Pollution Control Board, Indiana Department of Environmental Management Primary Website http:www.in.govlegislativeiac...

345

Microwave remote sensing of ionized air.  

SciTech Connect

We present observations of microwave scattering from ambient room air ionized with a negative ion generator. The frequency dependence of the radar cross section of ionized air was measured from 26.5 to 40 GHz (Ka-band) in a bistatic mode with an Agilent PNA-X series (model N5245A) vector network analyzer. A detailed calibration scheme is provided to minimize the effect of the stray background field and system frequency response on the target reflection. The feasibility of detecting the microwave reflection from ionized air portends many potential applications such as remote sensing of atmospheric ionization and remote detection of radioactive ionization of air.

Liao, S.; Gopalsami, N.; Heifetz, A.; Elmer, T.; Fiflis, P.; Koehl, E. R.; Chien, H. T.; Raptis, A. C. (Nuclear Engineering Division)

2011-07-01T23:59:59.000Z

346

Fluid Metrology Calibration Services - Air Speed  

Science Conference Proceedings (OSTI)

... National Institute of Standards and Technology provides calibration services for air speed instrumentation such as Pitot tubes, hot-wire or thermal ...

2013-02-11T23:59:59.000Z

347

Compressed Air Energy Storage Act (Kansas)  

Energy.gov (U.S. Department of Energy (DOE))

This act lays out regulations for the local authorities related to site selection, design, operation and monitoring for underground storage of compressed air.

348

Reactive Air Aluminizing - Energy Innovation Portal  

Reactive Air Aluminizing is a process for applying a protective coating on steel components in solid oxide fuel ... Building Energy Efficiency; ...

349

The Dynamics of Air Transportation System Transition  

E-Print Network (OSTI)

Both U.S. and European Air Transportation Systems face substantial challenges in transforming to meet future demand. This paper uses a feedback model to identify

Mozdzanowska, Aleksandra

350

Indoor Air Quality & Ventilation Group Staff Directory  

Science Conference Proceedings (OSTI)

Indoor Air Quality and Ventilation Group Staff. Staff Listing. Dr. Andrew K. Persily, Leader, Supervisory Mechanical Engineer, 301-975-6418. ...

2013-08-30T23:59:59.000Z

351

Lithium Air Electrodes - Available Technologies - PNNL  

Comparing metal air batteries, ... are in a race to find cutting edge technologies that deliver more powerful batteries in smaller packages and lower ...

352

Energy Basics: Air-Source Heat Pumps  

Office of Energy Efficiency and Renewable Energy (EERE) Indexed Site

from ductwork that protrudes through a wall or roof. More Information Visit the Energy Saver website for more information about the selection and performance of air-source...

353

Advanced Manufacturing Office: Compressed Air Systems  

NLE Websites -- All DOE Office Websites (Extended Search)

training and other resources Training Calendar Events Calendar Tools Tools to Assess Your Energy System AIRMaster+ Tool Scorecards and Simple Calculators Compressed Air Scorecard...

354

Radionuclide Air Emission Report for 2007  

E-Print Network (OSTI)

for Emissions of Radionuclides Other Than Radon FromHazardous Air Pollutants (Radionuclides), Availability ofLBNL to Revise Its Radionuclide NESHAP Monitoring Approach,

Wahl, Linnea

2008-01-01T23:59:59.000Z

355

Radionuclide Air Emission Report for 2009  

E-Print Network (OSTI)

the public from airborne radionuclide emissions. We requestfor Emissions of Radionuclides Other Than Radon FromFugitive Air Emissions of Radionuclides from Diffuse Sources

Wahl, Linnea

2010-01-01T23:59:59.000Z

356

Reactive Air Aluminizing - Energy Innovation Portal  

Reactive Air Aluminizing is a process for applying a protective coating on steel components in solid oxide fuel cells and other high temperature electrochemical devices.

357

Air Conditioner "Evolves" in Novel NIST Study  

Science Conference Proceedings (OSTI)

... A new NIST tool combining principles of engineering with those of natural evolution yielded the design for a more energy-efficient roof-top air ...

2013-09-03T23:59:59.000Z

358

Liquid phase thermal swing chemical air separation  

DOE Patents (OSTI)

A temperature swing absorption separation of oxygen from air is performed with an oxygen acceptor of alkali metal nitrate and nitrite. 2 figs.

Erickson, D.C.

1988-05-24T23:59:59.000Z

359

Future Air traffic management Concepts Evaluation Tool ...  

Solar Photovoltaic; Solar Thermal; Startup ... Actual air traffic data and weather information are utilized to evaluate an aircrafts flight-plan ...

360

Regulations for Air Quality (Quebec, Canada)  

Energy.gov (U.S. Department of Energy (DOE))

This Regulation establishes emission standards for particulates and gases, emission opacity standards, standards of air quality and control measures to prevent, eliminate or reduce the emission of...

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


361

CSEM WP 118 The Impact of the Clean Air Act Amendments of 1990  

E-Print Network (OSTI)

the externality affects (such as changes in manufacturing jobs and trade Vehicle Fleet Mix Trade balances National of the vehicle to direction from the steering wheel and brakes. Thus the driver responds to a visible need transportation, communication, manufacturing, enter- tainment, education, etc., within outlying communities

California at Berkeley. University of

362

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Takes Action to Stop the Sales of Air-Con Air Conditioner Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown to Violate Federal Energy Efficiency Appliance Standards DOE Takes Action to Stop the Sales of Air-Con Air Conditioner Models Shown to Violate Federal Energy Efficiency Appliance Standards September 23, 2010 - 12:00am Addthis Washington, DC - The Department of Energy announced today that it has taken action against Air-Con, International, requiring the company to stop selling certain air conditioning systems in the U.S. that have been shown to violate minimum energy efficiency appliance standards. DOE is proposing a civil penalty of more than $230,000 for importing and distributing these inefficient cooling products. This action and the proposed penalties are part of the Department's continued commitment to act aggressively to remove

363

Effect of Return Air Leakage on Air Conditioner Performance in Hot/Humid Climates  

E-Print Network (OSTI)

An experimental study was conducted to quantify the effect of return air leakage from hot/humid attic spaces on the performance of a residential air conditioner. Tests were conducted in psychrometric facilities where temperatures and humidities could be controlled closely. Return air leakage from hot attic spaces was simulated by assuming adiabatic mixing of the indoor air at normal conditions with the attic air at high temperatures. Effective capacity and Energy Efficiency Ratio both decreased with increased return air leakage. However, power consumption was relatively constant for all variables except outdoor temperature, which meant that for the same power consumption, the unit delivered much lower performance when there was return air leakage. The increase in sensible heat ratio (SHR) with increasing leakage showed one of the most detrimental effects of return air leakage on performance.

O'Neal, D. L.; Rodriguez, A.; Davis, M.; Kondepudi, S.

1996-01-01T23:59:59.000Z

364

DOE Takes Action to Stop the Sales of Air-Con Air Conditioner...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

action against Air-Con, International, requiring the company to stop selling certain air conditioning systems in the U.S. that have been shown to violate minimum energy...

365

Design of Air-cooled Microchannel Condensers for Mal-distributed Air Flow Conditions .  

E-Print Network (OSTI)

??Air-cooled condensers are routinely designed for a variety of applications, including residential air-conditioning systems. Recent attempts at improving the performance of these heat exchangers have (more)

Subramaniam, Vishwanath

2004-01-01T23:59:59.000Z

366

Identification and Tracking of Polluted Air Masses in the South-Central Coast Air Basin  

Science Conference Proceedings (OSTI)

Canister samples of air taken during the South-Central Coast Cooperative Air Monitoring Program (SCCCAMP) 1985 field study program were analyzed for concentrations of over 50 hydrocarbons as well as chlorofluorocarbons (CFCs), carbon monoxide, ...

G. E. Moore; S. G. Douglas; R. C. Kessler; J. P. Killus

1991-05-01T23:59:59.000Z

367

WearAir: Expressive T-shirts for Air Quality Sensing Sunyoung Kim and Eric Paulos  

E-Print Network (OSTI)

and arrays of LEDs (light-emitting diodes). The T-shirt illuminates in response to the sensed air quality

Sadeh, Norman M.

368

Influence of air conditioning management on heat island in Paris air street temperatures  

E-Print Network (OSTI)

spatial cartography of air- cooled chillers and cooling towers in the city of Paris and surroundings have); secondly the actual situation including individual air dry coolers, wet cooling towers and an urban cooling the air cooling demand. Results of a meso-scale meteorological model (MESO-NH), coupled to an urban energy

369

U.S. Air Force Fact Sheet Air Force Reserve Officer Training Corps  

E-Print Network (OSTI)

merged under the newly created parent organization, HQ Air Force Officer and Accession Training School-to-day operations of either organization. In June 2008, HQ AFOATS was redesignated as the Jeanne M. Holm Center,796 new Second Lieutenants who entered active duty in the United States Air Force. Organization Air Force

Su, Xiao

370

Troubleshooting the residential air conditioning system  

Science Conference Proceedings (OSTI)

In order to effectively diagnose problems in a residential air conditioning system, the technician should develop and follow a logical step-by-step troubleshooting procedure. A list of problems, along with possible causes and solutions, that a technician may encounter when servicing a residential air conditioner is presented.

Puzio, H. [Sussex County Vocational Technical School, Sparta, NJ (United States)

1996-01-01T23:59:59.000Z

371

Zone based indoor mobile air pollution monitoring  

Science Conference Proceedings (OSTI)

Pollution is one of the main problems that humans are suffering from. Moreover air pollution is one of the hardest to escape. Although human spend most of their time indoor, most of the previous pollution monitoring studies focused on outdoor air monitoring. ... Keywords: indoor pollution, mobile sensing, nfc

Noura Alhakbani, Eiman Kanjo

2013-09-01T23:59:59.000Z

372

Air Quality Program Specialist Vandenberg AFB, California  

E-Print Network (OSTI)

Air Quality Program Specialist Vandenberg AFB, California POSITION An Air Quality Program, California. ORGANIZATION CEMML is a research, education and service unit within the Warner College of Natural of Santa Barbara on the central coast of California. The base and its 45 miles of scenic coastline is home

373

Model Representation of Local Air Quality Characteristics  

Science Conference Proceedings (OSTI)

Daily (24 h) and hourly air quality data at several sites are used to examine the performance of the fifth-generation Pennsylvania State UniversityNCAR Mesoscale Model (MM5)Community Multiscale Air Quality Model (CMAQ) system over a 3-month ...

Stephen F. Mueller

2009-05-01T23:59:59.000Z

374

Air Temperature in the Undulator Hall  

SciTech Connect

Various analyses have been performed recently to estimate the performance of the air conditioning (HVAC) system planned for the Undulator Hall. This reports summarizes the results and provides an upgrade plan to be used if new requirements are needed in the future. The estimates predict that with the planned loads the tunnel air temperature will be well within the allowed tolerance during normal operation.

Not Available

2010-12-07T23:59:59.000Z

375

Improving Regional Air Quality with Wind Energy  

DOE Green Energy (OSTI)

This model documentation is designed to assist State and local governments in pursuing wind energy purchases as a control measure under regional air quality plans. It is intended to support efforts to draft State Implementation Plans (SIPs), including wind energy purchases, to ensure compliance with the standard for ground-level ozone established under the Clean Air Act.

Not Available

2005-05-01T23:59:59.000Z

376

Controlling teams of uninhabited air vehicles  

Science Conference Proceedings (OSTI)

We describe a Multi-Agent System (MAS) for controlling teams of uninhabited air vehicles (UAVs) in the context of a larger system that has been used to evaluate potential concepts of use and technologies. The approach is one of a decision-making partnership ... Keywords: human-machine partnership, multi-agent system, uninhabited air vehicles, variable autonomy

Jeremy W. Baxter; Graham S. Horn

2005-07-01T23:59:59.000Z

377

central air conditioner | OpenEI  

Open Energy Info (EERE)

central air conditioner central air conditioner Dataset Summary Description View 2010 energy efficiency data from AeroSys Inc, Coaire, Cold Point, First Operations, LG Electronics, Nordyne, and Quietside manufacturers. Data includes cooling capacity, cooling performance, heating capacity, and heating performance. Spreadsheet was created by combining the tables in pdf files that are included in the zip file. Source Energy Applicance Data - United States Federal Trade Commission, www.ftc.gov Date Released Unknown Date Updated Unknown Keywords air conditioner central air conditioner efficiency efficient energy heat pump Data application/vnd.ms-excel icon 2010_CentralAC_All.xls (xls, 82.4 KiB) application/zip icon 2010CentralAirConditioner.zip (zip, 398.2 KiB) Quality Metrics Level of Review Some Review

378

Air control can improve field heater efficiency  

SciTech Connect

Independent field tests have demonstrated that the proper selection of primary and secondary air controls for wellhead gas dehydrators can reduce their burner fuel gas consumption by at least 30%. The tests were conducted by G.A. Baca and Associates Ltd., an engineering consulting firm located in Santa Fe, N.M. The new thermostat, venturi burner, and automatic secondary air control combination used in the tests were developed by Weatherford International as part of its Engineered Controls and Instruments (ECI) product line. The principle innovation of Weatherford's ECI burner/control combination is the Automatic Secondary Air Shutter, a device which limits the supply of secondary air surrounding the venturi burner. This air-flow control provides significant improvements in combustion efficiency compared to burners without such controls. Patents for the shutter and burner equipment are pending.

Zygmunt, S.J.; Giovanini, B.

1984-03-26T23:59:59.000Z

379

Indoor Air Quality Observations in Public Schools  

E-Print Network (OSTI)

Investigations of indoor air qmlity or indoor environment problems were accomplished in seven different Texas schools. The schools were located in hot and humid climates. Comfort and mildew were the most frequent complaints. In all cases, the air-conditioning system maintenance and operation was a primary factor in the problem cause and solution. The significance of problems investigated cculd have been minimized had the symptoms been addressed when they were reported the first time. Preventive maintenance and better housekeeping of air-conditioning systems in Texas schools will improve the indoor environment. Schools are encouraged to be more aggressive in preventive maintenance and plan for indoor air quality and energy efficiency in school air-conditioning retrofits.

McClure, J. D.; Estes, J. M.

1990-01-01T23:59:59.000Z

380

average air temperature | OpenEI  

Open Energy Info (EERE)

average air temperature average air temperature Dataset Summary Description (Abstract): Air Temperature at 10 m Above The Surface Of The Earth (deg C)NASA Surface meteorology and Solar Energy (SSE) Release 6.0 Data Set (Nov 2007)22-year Monthly & Annual Average (July 1983 - June 2005)Parameter: Air Temperature at 10 m Above The Surface Of The Earth (deg C)Internet: http://eosweb.larc.nasa.gov/sse/Note 1: SSE Methodology & Accuracy sections onlineNote 2: Lat/Lon values indicate the lower left corner of a 1x1 degree region. Negative values are south and west; Source U.S. National Aeronautics and Space Administration (NASA), Surface meteorology and Solar Energy (SSE) Date Released March 31st, 2009 (5 years ago) Date Updated April 01st, 2009 (5 years ago) Keywords average air temperature

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


381

Air Pollution Control (Michigan) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Pollution Control (Michigan) Air Pollution Control (Michigan) Air Pollution Control (Michigan) < Back Eligibility Utility Fed. Government Commercial Agricultural Investor-Owned Utility State/Provincial Govt Industrial Construction Municipal/Public Utility Local Government Residential Installer/Contractor Rural Electric Cooperative Tribal Government Low-Income Residential Schools Retail Supplier Institutional Multi-Family Residential Systems Integrator Fuel Distributor Nonprofit General Public/Consumer Transportation Program Info State Michigan Program Type Environmental Regulations Siting and Permitting Provider Department of Environmental Quality This rule requires an annual report from a commercial, industrial, or governmental source of emission of an air contaminant if, in the judgment of the Department, information on the quantity and composition of an air

382

Hot Air Stratification of Ceiling Air Supply in a Large Space Building  

E-Print Network (OSTI)

The effects of different states of air supply and airflow patterns on temperature gradient distribution are calculated and analyzed with the help of FFSV3.0 software, using the LB models and LES and RANS methods. An experimental study with upper supply and upper return air flow was performed in normal airflow room. The results were compared with numerical simulation results and were found to agree well. Information on delaminating laws, and measurements of the relationship of delaminating heights and air supply temperature and velocity is also presented. According to the simulation results, a formula that avoids hot air delaminating in ceiling air supply is derived, which can guide engineering design.

Wang, H.; Wang, Z.; Liu, C.

2006-01-01T23:59:59.000Z

383

Air Quality: Acronym List Department: Chemical and General Safety  

E-Print Network (OSTI)

: Program Manager Authority: ES&H Manual, Chapter 30, Air Quality1 ACM asbestos-containing material AHA areaAir Quality: Acronym List Department: Chemical and General Safety Program: Air Quality Owner hazard analysis AQPM air quality program manager ARP accidental release prevention ATCM air toxic control

Wechsler, Risa H.

384

Simple Interactive Models for better air quality (SIM-air) | Open Energy  

Open Energy Info (EERE)

Simple Interactive Models for better air quality (SIM-air) Simple Interactive Models for better air quality (SIM-air) Jump to: navigation, search Tool Summary Name: Simple Interactive Models (SIM-air) Agency/Company /Organization: UrbanEmissions.info Sector: Climate, Energy User Interface: Desktop Application Complexity/Ease of Use: Moderate Website: urbanemissions.info/model-tools/sim-air.html Cost: Free Related Tools Tool for Selecting CDM Methods & Technologies ProForm Environmental Impact and Sustainability Applied General Equilibrium Model (ENVISAGE) ... further results Find Another Tool FIND DEVELOPMENT IMPACTS ASSESSMENT TOOLS A set of software-based integrated air pollution analysis tools that illustrate how cities in developing countries, despite the informational, institutional and infrastructural limitations they face, can begin to

385

Atmospheric CO2 From Flask Air Samples at 10 Sites in the SIO Air Sampling  

NLE Websites -- All DOE Office Websites (Extended Search)

Flask Air Samples, SIO Network Flask Air Samples, SIO Network Atmospheric CO2 From Flask Air Samples at 10 Sites in the SIO Air Sampling Network Scripps Institution of Oceanography Monitoring Sites Scripps Institution of Oceanography Monitoring Sites Mauna Loa, Hawaii Mauna Loa weekly average CO2 concentrations derived from continuous air samples Barrow, Alaska American Samoa South Pole Daily average CO2 concentrations derived from continuous air samples Alert, NWT, Canada Cape Kumukahi Christmas Island Baring Head Kermadec Island La Jolla Pier La Jolla Pier weekly average CO2 concentrations derived from continuous air samples PDF Documentation available as Atmospheric Carbon Dioxide Concentrations at 10 Locations Spanning Latitudes 82°N to 90°S, (NDP-001a) For information on calibration and some additional literature, go to

386

Research review: Indoor air quality control techniques  

Science Conference Proceedings (OSTI)

Techniques for controlling the concentration of radon, formaldehyde, and combustion products in the indoor air are reviewed. The most effective techniques, which are generally based on limiting or reducing indoor pollutant source strengths, can decrease indoor pollutant concentrations by a factor of 3 to 10. Unless the initial ventilation rate is unusually low, it is difficult to reduce indoor pollutant concentrations more than approximately 50% by increasing the ventilation rate of an entire building. However, the efficiency of indoor pollutant control by ventilation can be enhanced through the use of local exhaust ventilation near concentrated sources of pollutants, by minimizing short circuiting of air from supply to exhaust when pollutant sources are dispersed and, in some situations, by promoting a displacement flow of air and pollutants toward the exhaust. Active air cleaning is also examined briefly. Filtration and electrostatic air cleaning for removal of particles from the indoor air are the most practical and effective currently available techniques of air cleaning. 49 refs., 7 figs.

Fisk, W.J.

1986-10-01T23:59:59.000Z

387

Preparing for the clean air act amendments  

SciTech Connect

The U.S. Environmental Protection Agency (EPA) and state air quality control agencies are in the midst of developing regulations and programs to meet the ambitious goals of the Clean Air Act Amendment (CAAA) of 1990. The CAAA--which call for stricter air quality standards, a greater number of pollutants and sources to be regulated, new operating permits, and more stringent enforcement of air quality violations--are expected to have a significant impact on virtually every facility in the country. An important deadline in the implementation of the CAAA is November 1993. That is when individual states must submit their proposed operating permit programs to the EPA, as mandated by Title 5 of the Amendments. The EPA then has one year after receiving a state program to accept or reject it. Once a state's program is accepted, all major sources of air pollution in that state have one year to apply for an operating air permit. Although the initial deadlines for business and industry are up to two years away, sufficient information is now available to take the first steps toward compliance with the new air quality regulations. Even while the details of the new rules are being hammered out, plant engineering can and should begin laying the groundwork for their own permit applications. Time and effort spent preparing now for the provisions of the CAAA will pay off in the long run.

Boomer, B.; Bensinger, D. (Midwest Research Inst., Kansas City, MO (United States) Midwest Research Inst., Cary, NC (United States))

1993-09-09T23:59:59.000Z

388

Coordination of energy and air quality management  

SciTech Connect

The project had two goals: first, to demonstrate industrial firms can improve plant energy efficiency as air pollution emissions are reduced; second, to demonstrate that both Seattle City Light and PSAPCA could more effectively accomplish their individual objectives through mutual cooperation, even though the two agencies have very different missions. The cooperative efforts promised benefits for all the parties involved. Seattle City Light hoped that PSAPCA`s knowledge of the likely developments in air pollution controls would help the utility better target energy conservation opportunities among its industrial customers. PSAPCA hoped that the financial assistance offer by Seattle City Light through its conservation programs would make industry less resistant to PSAPCA enforcement of new air pollution control regulations. Finally, individual industrial firms could mitigate some of the cost of meeting the new air pollution control standards. The results of the project were mixed. CEAM did demonstrate that industrial plants can improve energy efficiency as they reduce air pollution emissions, but the relationship between air pollution reduction and energy consumption is complicated; and the project was less successful in meeting its second goal. The project design did not include a measure by which results could be compared against what the two agencies would have accomplished had they not collaborated. Moreover, the project could have benefited substantially from a more complete implementation plan and the production of data quantifying the energy conservation potential resulting from the development of more stringent air pollution control regulations for each of Seattle`s major industries.

1992-12-01T23:59:59.000Z

389

Subsonic Tests of a Flush Air Data Sensing System Applied to a Fixed-Wing Micro Air Vehicle  

Science Conference Proceedings (OSTI)

Flush air data sensing (FADS) systems have been successfully tested on the nose tip of large manned/unmanned air vehicles. In this paper we investigate the application of a FADS system on the wing leading edge of a micro (unmanned) air vehicle (MAV) ... Keywords: Extended minimum resource allocating neural networks, Fault accommodation, Flush air data sensing systems, Micro (unmanned) air vehicle

Ihab Samy; Ian Postlethwaite; Dawei Gu

2009-03-01T23:59:59.000Z

390

Compressed Air Energy Storage Demonstration Newsletter  

Science Conference Proceedings (OSTI)

The Compressed Air Energy Storage (CAES) Demonstration Project includes the phased planning, engineering design, construction, demonstration, and performance monitoring of two CAES plants. One plant will be a system rated at 300 MWs for up to 10 hours with a below-ground reservoir for bulk energy air storage, and the other will be a system rated at 15 MWs for 2 hours with above-ground air vessel/piping. This is a critical technology demonstration project that is necessary to enable higher penetration of ...

2011-04-21T23:59:59.000Z

391

Air Barriers for Residential and Commercial Buildings  

NLE Websites -- All DOE Office Websites (Extended Search)

Air Barriers for Residential and Air Barriers for Residential and Commercial Buildings Diana Hun, PhD Oak Ridge National Laboratory dehun@ornl.gov 865-574-5139 April 4, 2013 BTO Program Peer Review 2 | Building Technologies Office eere.energy.gov Problem Statement & Project Focus - Air leakage is a significant contributor to HVAC loads - ~50% in residential buildings (Sherman and Matson 1997) - ~33% of heating loads in office buildings (Emmerich et al. 2005) - Airtightness of buildings listed in BTO prioritization tool

392

Combustion Air Preheat on Steam Cracker Furnaces  

E-Print Network (OSTI)

Beginning in 1978, Exxon has started up nine large new steam cracking furnaces with various levels of air preheat, and has seven more under construction. Sources of heat have included process streams, flue gas and gas turbine exhaust. Several aspects of the technology employed have been patented in the U.S. and elsewhere. This paper discusses the use of process heat and gas turbine exhaust for air preheat to provide plant fuel savings of about 8% over and above a modern, fuel efficient alternative furnace without air preheat.

Kenney, W. F.

1983-01-01T23:59:59.000Z

393

Air blast type coal slurry fuel injector  

SciTech Connect

A device to atomize and inject a coal slurry in the combustion chamber of an internal combustion engine, and which eliminates the use of a conventional fuel injection pump/nozzle. The injector involves the use of compressed air to atomize and inject the coal slurry and like fuels. In one embodiment, the breaking and atomization of the fuel is achieved with the help of perforated discs and compressed air. In another embodiment, a cone shaped aspirator is used to achieve the breaking and atomization of the fuel. The compressed air protects critical bearing areas of the injector.

Phatak, Ramkrishna G. (San Antonio, TX)

1986-01-01T23:59:59.000Z

394

Geomagnetic Field and Air Shower Simulations  

E-Print Network (OSTI)

The influence of the geomagnetic field on the development of air showers is studied. The well known International Geomagnetic Reference Field was included in the AIRES air shower simulation program as an auxiliary tool to allow calculating very accurate estimations of the geomagnetic field given the geographic coordinates, altitude above sea level and date of a given event. Some test simulations made for representative cases indicate that some quantities like the lateral distribution of muons experiment significant modifications when the geomagnetic field is taken into account.

A. Cillis; S. J. Sciutto

1997-12-30T23:59:59.000Z

395

Air blast type coal slurry fuel injector  

DOE Patents (OSTI)

A device to atomize and inject a coal slurry in the combustion chamber of an internal combustion engine is disclosed which eliminates the use of a conventional fuel injection pump/nozzle. The injector involves the use of compressed air to atomize and inject the coal slurry and like fuels. In one embodiment, the breaking and atomization of the fuel is achieved with the help of perforated discs and compressed air. In another embodiment, a cone shaped aspirator is used to achieve the breaking and atomization of the fuel. The compressed air protects critical bearing areas of the injector.

Phatak, R.G.

1984-08-31T23:59:59.000Z

396

Air Barriers for Residential and Commercial Buildings  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Barriers for Residential and Air Barriers for Residential and Commercial Buildings Diana Hun, PhD Oak Ridge National Laboratory dehun@ornl.gov 865-574-5139 April 4, 2013 BTO Program Peer Review 2 | Building Technologies Office eere.energy.gov Problem Statement & Project Focus - Air leakage is a significant contributor to HVAC loads - ~50% in residential buildings (Sherman and Matson 1997) - ~33% of heating loads in office buildings (Emmerich et al. 2005) - Airtightness of buildings listed in BTO prioritization tool

397

Change-over valve for air suspension  

Science Conference Proceedings (OSTI)

A change-over valve is described for an air suspension interposed between a main air chamber formed to surround a shock absorber provided with a piston rod and an auxiliary air chamber, comprising: a valve base having a first hole through which the piston rod extends and a second hole into which a valve body is inserted; the valve body disposed in the second hole; a holder disposed in the second hole; and means removably fixed to the piston rod extending through the first hole to connect the piston rod with the valve base while preventing the holder from falling out.

Buma, S.

1987-04-28T23:59:59.000Z

398

SunShot Initiative: CSP Tower Air Brayton Combustor  

NLE Websites -- All DOE Office Websites (Extended Search)

CSP Tower Air Brayton Combustor to someone by E-mail Share SunShot Initiative: CSP Tower Air Brayton Combustor on Facebook Tweet about SunShot Initiative: CSP Tower Air Brayton...

399

Ductless Mini-Split Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners August 9, 2012 - 4:05pm Addthis A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. What does this mean for me? A ductless mini-split air conditioner is easier to install than a central air conditioning system. A ductless mini-split air conditioner provides zoned air conditioning without ducting. A ductless mini-split air conditioner is relatively easy to install and does not provide an entry point for intruders as some room air conditioners do. Ductless, mini split-system air-conditioners (mini splits) have numerous

400

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network (OSTI)

easyairsealing .suchthattheefficacyofairsealingis determinedbytheinlet that prevents easy air sealing DeltaQ TheDeltaQtest

Walker, Iain S.

2010-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


401

Measurements of the Electrical Conductivities of Air over Hot Water  

Science Conference Proceedings (OSTI)

Measurements of the conduction current between two electrodes in air over recently boiled water have been interpreted by Carlon as indicating that the humidified air became highly conductive and that large numbers of ions were produced in the air ...

C. B. Moore; B. Vonnegut

1988-03-01T23:59:59.000Z

402

Air Temperature Model Evaluation in the North Mediterranean Belt Area  

Science Conference Proceedings (OSTI)

A comparative assessment of air temperature models, using hourly and daily air temperature measurements in 34 different stations in the north Mediterranean belt, is presented. Four air temperature models were used to estimate hourly and daily ...

Julia Bilbao; Argimiro H. de Miguel; Harry D. Kambezidis

2002-08-01T23:59:59.000Z

403

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network (OSTI)

ResidentialACMManual,Section 3.12.5Duct/AirHandlerResidentialACMManual,Section3.12.5Duct/Air HandlerleakageofairhandlersforthepurposesoftheACM. Based

Walker, Iain S.

2010-01-01T23:59:59.000Z

404

Ductless Mini-Split Air Conditioners | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners Ductless Mini-Split Air Conditioners August 9, 2012 - 4:05pm Addthis A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. A ductless mini-split air conditioner is one solution to cooling part of a house. | Photo courtesy of ©iStockphoto/LUke1138. What does this mean for me? A ductless mini-split air conditioner is easier to install than a central air conditioning system. A ductless mini-split air conditioner provides zoned air conditioning without ducting. A ductless mini-split air conditioner is relatively easy to install and does not provide an entry point for intruders as some room air conditioners do. Ductless, mini split-system air-conditioners (mini splits) have numerous

405

An Analysis of Air Passenger Average Trip Lengths and Fare Levels in US Domestic Markets  

E-Print Network (OSTI)

Air Service Inc. (helicopter) Redwing Aviation Inc. (Red Wing Air; Redwing Airways Inc. ) Reeves Air RZ RX* 7R RQ

Huang, Sheng-Chen Alex

2000-01-01T23:59:59.000Z

406

Opportunities for Saving Energy and Improving Air Quality in Urban Heat Islands  

E-Print Network (OSTI)

Refrigeration, and Air conditioning Engineers, Atlanta,Refrigeration, and Air Conditioning Engineers, Atlanta,Refrigeration, and Air Conditioning Engineers, Atlanta,

Akbari, Hashem

2008-01-01T23:59:59.000Z

407

Gas turbine engine braking and method  

SciTech Connect

A method is described of decelerating a ground vehicle driven by a gas turbine engine having a gas generator section and a free turbine output power section driven by a gas flow from the gas generator section, comprising the steps of: altering the incidence of gas flow from the gas generator section onto the free turbine section whereby said gas flow opposes rotation of the free turbine section; increasing gas generator section speed; and subsequent to said altering and increasing steps, selectively mechanically interconnecting said gas generator and free turbine sections whereby the rotational inertia of the gas generator section tends to decelerate the free turbine section.

Mattson, G.; Woodhouse, G.

1980-07-01T23:59:59.000Z

408

Electric vehicle regenerative antiskid braking and traction ...  

Patent Number: 5,450,324: Issued: September 12, 1995: Official Filing: View the Complete Patent at the US Patent & Trademark Office: Lab: Idaho ...

409

Kirland Air Force Base wins Robot Rodeo  

NLE Websites -- All DOE Office Websites (Extended Search)

Kirland Air Force Base wins Robot Rodeo Kirland Air Force Base wins Robot Rodeo Community Connections: Our link to Northern New Mexico Communities Latest Issue:Dec. 2013 - Jan. 2014 All Issues » submit Kirland Air Force Base wins Robot Rodeo Hazardous devices teams test their maneuvering skills July 1, 2013 Students from Valarde Middle School won the video competition in the Best in Show and Middle School categories. They are shown here with sixth-grade teacher Jimmy Lara. During the Robot Rodeo, an unseen operator attempts to conduct reconnaissance and rescue injured personnel Contact Editor Linda Anderman Email Community Programs Office Kurt Steinhaus Email Kirland Air Force Base wins Robot Rodeo Police and public safety teams from as far away as New Jersey recently convened in Albuquerque to test their ability to remotely deploy robots

410

DOE Investigates Possible Air Conditioner Efficiency Violations |  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Investigates Possible Air Conditioner Efficiency Violations Investigates Possible Air Conditioner Efficiency Violations DOE Investigates Possible Air Conditioner Efficiency Violations February 15, 2012 - 5:13pm Addthis The Department of Energy's Office of Enforcement is committed to its compliance enforcement responsibilities with regard to federal energy conservation standards and ensuring that all those subject to the requirements are treated fairly and equally. Today, the Office of Enforcement issued a series of subpoenas as part of an investigation to determine whether manufacturers of split-system air conditioners are making and distributing in the U.S. condensing units that do not meet the current 13 SEER (Seasonal Energy Efficiency Ratio) federal energy conservation standard, which has been the standard since 2006.

411

Radionuclide Air Emission Report for 2008  

E-Print Network (OSTI)

particulate air Joint BioEnergy Institute Lawrence Hall ofBuilding 978, the Joint BioEnergy Institute, are shown onStreet Facility) Joint BioEnergy Institute (JBEI) C-14, Cd-

Wahl, Linnea

2009-01-01T23:59:59.000Z

412

Radionuclide Air Emission Report for 2009  

E-Print Network (OSTI)

particulate air Joint BioEnergy Institute Lawrence Hall ofBuilding 978, the Joint BioEnergy Institute, are shown onStreet Facility) Joint BioEnergy Institute (JBEI) Produced

Wahl, Linnea

2010-01-01T23:59:59.000Z

413

Air Quality Regulations (Pennsylvania) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

regulates more than 70,000 inspection points such as pollution control devices, boilers, fuels and paints at 3,650 facilities that produce air pollution in Pennsylvania. The...

414

Imaging Lithium Air Electrodes | ornl.gov  

NLE Websites -- All DOE Office Websites (Extended Search)

Neutron Imaging Reveals Lithium Distribution in Lithium-Air Electrodes Neutron Imaging Reveals Lithium Distribution in Lithium-Air Electrodes Agatha Bardoel - January 01, 2013 Image produced by neutron-computed tomography. The next step in revolutionizing electric vehicle capacity Research Contacts: Hassina Bilheux, Jagjit Nanda, and S. Pannala Using neutron-computed tomography, researchers at the CG-1D neutron imaging instrument at Oak Ridge National Laboratory's High Flux Isotope Reactor (HFIR) have successfully mapped the three-dimensional spatial distribution of lithium products in electrochemically discharged lithium-air cathodes. Lithium-air chemistry promises very high-energy density that, if successful, would revolutionize the world of electric vehicles by extending their range to 500 miles or more. The high-energy density comes from

415

Intercalibration of Broadband Geostationary Imagers Using AIRS  

Science Conference Proceedings (OSTI)

Geostationary simultaneous nadir observations (GSNOs) are collected for Earth Observing System (EOS) Atmospheric Infrared Sounder (AIRS) on board Aqua and a global array of geostationary imagers. The imagers compared in this study are on (...

Mathew M. Gunshor; Timothy J. Schmit; W. Paul Menzel; David C. Tobin

2009-04-01T23:59:59.000Z

416

Ventilation Controller for Improved Indoor Air Quality  

Iain Walker and colleagues at Berkeley Lab have developed a dynamic control system for whole-house ventilation fans that provides maximal air quality while reducing by 18-44% the energy spent on ventilation. The system, the Residential Integrated ...

417

Improving Air Quality with Solar Energy  

DOE Green Energy (OSTI)

This fact sheet series highlights how renewable energy and energy efficiency technologies can and are being used to reduce air emissions and meet environmental goals, showcasing case studies and technology-specific topics. This one focus on solar energy technologies.

Not Available

2008-04-01T23:59:59.000Z

418

Large panel design for containment air baffle  

SciTech Connect

The movable air baffle shield means in accordance with the present invention provides an efficient method of cooling the space surrounding the containment vessel while also providing the capability of being moved away from the containment vessel during inspection. The containment apparatus comprises a generally cylindrical sealed containment vessel for containing at least a portion of a nuclear power generation plant, a disparate shield building surrounding and housing the containment vessel therein and spaced outwardly thereof so as to form an air annulus in the space between the shield building and the containment vessel, a shield baffle means positioned in the air annulus around at least a portion of the sides of the containment vessel providing a coolant path between the baffle means and the containment vessel to permit cooling of the containment vessel by air, the shield baffle means being movable to afford access to the containment vessel.

Orr, Richard S. (Pittsburgh, PA)

1992-01-01T23:59:59.000Z

419

COMBUSTION-GENERATED INDOOR AIR POLLUTION  

E-Print Network (OSTI)

x A Emission Characteristics in Two Stage Combustion. PaperInternational) on Combustion, Tokyo (August, 1974). Chang,fll , J I ___F J "J LBL-S9lS COMBUSTION-GENERATED INDOOR AIR

Hollowell, C.D.

2010-01-01T23:59:59.000Z

420

climate and energy up in the air  

Science Conference Proceedings (OSTI)

07/8 - CLIMATE AND ENERGY UP IN THE AIR ... motion to move to a final vote, which led proponents of the resolution or an alternative to be proposed by Sen.

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


421

Large panel design for containment air baffle  

DOE Patents (OSTI)

The movable air baffle shield means in accordance with the present invention provides an efficient method of cooling the space surrounding the containment vessel while also providing the capability of being moved away from the containment vessel during inspection. The containment apparatus comprises a generally cylindrical sealed containment vessel for containing at least a portion of a nuclear power generation plant, a disparate shield building surrounding and housing the containment vessel therein and spaced outwardly thereof so as to form an air annulus in the space between the shield building and the containment vessel, a shield baffle means positioned in the air annulus around at least a portion of the sides of the containment vessel providing a coolant path between the baffle means and the containment vessel to permit cooling of the containment vessel by air, the shield baffle means being movable to afford access to the containment vessel. 9 figs.

Orr, R.S.

1992-12-08T23:59:59.000Z

422

Energy Efficiency in Compressed Air Systems  

E-Print Network (OSTI)

Energy use in compressed air systems accounts for typically 10% of the total industrial electricity consumption. It also accounts for close to 99% of the CO2 footprint of an air compressor and approximately 80% of the life cycle costs of a compressor, over its lifetime. Considering these facts, it is sometimes surprising to see the lack of attention to compressed air systems in industry. This paper attempts to create awareness as to how a great deal of energy can be saved through a conscious process of selection and use of compressed air systems, bringing substantial benefits in economics and the environment. It also attempts to highlight the relative importance of energy savings over the costs of investments made in energy saving features and processes.

Hingorani, A.; Pavlov, A.

2010-01-01T23:59:59.000Z

423

Automobile air-conditioning unit. Final report  

SciTech Connect

In this study the refrigerant in the automobile air-conditioner is compressed by thermal energy in a unique compression system rather than by work in a standard compressor. The compression uses an intermittent compression process with a solid absorbent. The vapor is absorbed by an absorbent at relatively low temperature and ejected as the absorbent temperature is raised. A set of one way valves limits flow to one direction. Major contributions are heat transfer requirements, molecular sieve-refrigerant matching, minimizing non-producing mass, solving thermal fatigue and shock problems, and applying this to automobile air-conditioning. The performance study shows energy savings up to fifty percent are possible, depending on engine load. A twenty percent energy savings with the vehicle tested with the air-conditioner in operation is average. The study also showed that less fuel is used with the windows open than with the air-conditioner operating.

Schaetzle, W.J.

1982-12-01T23:59:59.000Z

424

Effects of Air Pollution Control on Climate  

E-Print Network (OSTI)

Urban air pollution and climate are closely connected due to shared generating processes (e.g., combustion) for emissions of the driving gases and aerosols. They are also connected because the atmospheric lifecycles of ...

Prinn, Ronald G.

425

A Bad Air Day in Houston  

Science Conference Proceedings (OSTI)

A case study from the Texas Air Quality Study 2000 field campaign illustrates the complex interaction of meteorological and chemical processes that produced a high-pollution event in the Houston area on 30 August 2000. High 1-h ozone ...

R. M. Banta; C. J. Senff; J. Nielsen-Gammon; L. S. Darby; T. B. Ryerson; R. J. Alvarez; S. P. Sandberg; E. J. Williams; M. Trainer

2005-05-01T23:59:59.000Z

426

High-energy metal air batteries  

DOE Patents (OSTI)

Disclosed herein are embodiments of lithium/air batteries and methods of making and using the same. Certain embodiments are pouch-cell batteries encased within an oxygen-permeable membrane packaging material that is less than 2% of the total battery weight. Some embodiments include a hybrid air electrode comprising carbon and an ion insertion material, wherein the mass ratio of ion insertion material to carbon is 0.2 to 0.8. The air electrode may include hydrophobic, porous fibers. In particular embodiments, the air electrode is soaked with an electrolyte comprising one or more solvents including dimethyl ether, and the dimethyl ether subsequently is evacuated from the soaked electrode. In other embodiments, the electrolyte comprises 10-20% crown ether by weight.

Zhang, Ji-Guang; Xiao, Jie; Xu, Wu; Wang, Deyu; Williford, Ralph E.; Liu, Jun

2013-07-09T23:59:59.000Z

427

Improving Air Quality with Solar Energy  

DOE R&D Accomplishments (OSTI)

This fact sheet series highlights how renewable energy and energy efficiency technologies can and are being used to reduce air emissions and meet environmental goals, showcasing case studies and technology-specific topics. This one focus on solar energy technologies.

2008-04-00T23:59:59.000Z

428

AltAir Fuels | Open Energy Information  

Open Energy Info (EERE)

Sector Renewable Energy Product Seattle-based developer of projects for the production of jet fuel from renewable and sustainable oils. References AltAir Fuels1 LinkedIn...

429

Air leakage of Insulated Concrete Form houses  

E-Print Network (OSTI)

Air leakage has been shown to increase building energy use due to additional heating and cooling loads. Although many construction types have been examined for leakage, an exploration of a large number of Insulated Concrete ...

Durschlag, Hannah (Hanna Rebekah)

2012-01-01T23:59:59.000Z

430

Knowledge Partnership for Measuring Air Pollution and Greenhouse...  

Open Energy Info (EERE)

Measuring Air Pollution and Greenhouse Gas Emissions in Asia Jump to: navigation, search Name Knowledge Partnership for Measuring Air Pollution and Greenhouse Gas Emissions in Asia...

431

Electrolux Gibson Air Conditioner and Equator Clothes Washer...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing Electrolux Gibson Air Conditioner and Equator Clothes Washer Fail DOE Energy Star Testing...

432

Air Cooling Technology for Power Electronics Thermal Control (Presentation)  

DOE Green Energy (OSTI)

Assessing potential for air cooling in power electronics is a critical factor in power electronics equipment. NREL aims to assess effective air cooling techniques for power electronics technologies.

Bharathan, D.

2007-11-14T23:59:59.000Z

433

Does the Air-Conditioning Engineering Rubric Work in Residences...  

NLE Websites -- All DOE Office Websites (Extended Search)

Does the Air-Conditioning Engineering Rubric Work in Residences? Title Does the Air-Conditioning Engineering Rubric Work in Residences? Publication Type Conference Paper LBNL...

434

Carbon Monoxide, Ozone, Hydrocarbon Air Quality Standards, and...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Carbon Monoxide, Ozone, Hydrocarbon Air Quality Standards, and Related Emission Requirements (Ohio) Carbon Monoxide, Ozone, Hydrocarbon Air Quality Standards, and Related Emission...

435

Secondary air interaction with main flow in axial turbines.  

E-Print Network (OSTI)

??Secondary air, known as purge air, is injected through seals in the hub and shroud of axial turbines to prevent hot gas ingestion into the (more)

Zlatinov, Metodi B. (Metodi Blagoev)

2011-01-01T23:59:59.000Z

436

Numerical Simulation Study on Transpired Solar Air Collector  

E-Print Network (OSTI)

The unglazed transpired solar air collector is now a well-recognized solar air heater for heating outside air directly. In this article, researchers introduced numerical simulation tools into the solar air collector research area, analyzed the performance characteristics of the unglazed transpired solar air collector and compared them with several kinds of traditional solar air collectors. The results showed that the unglazed transpired solar air collector has unparalleled advantages in the ventilation preheating area and also proves that CFD tools have their own advantages in the solar air collector research area.

Wang, C.; Guan, Z.; Zhao, X.; Wang, D.

2006-01-01T23:59:59.000Z

437

Effects of air infiltration on the effective thermal conductivity...  

NLE Websites -- All DOE Office Websites (Extended Search)

Effects of air infiltration on the effective thermal conductivity of internal fiberglass insulation and on the delivery of thermal capacity via ducts Title Effects of air...

438

Clean Air Act General Conformity Requirements and the National...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Clean Air Act General Conformity Requirements and the National Environmental Policy Act Process Clean Air Act General Conformity Requirements and the National Environmental Policy...

439

Shale Gas Development Challenges: Air | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Centers Field Sites Power Marketing Administration Other Agencies You are here Home Shale Gas Development Challenges: Air Shale Gas Development Challenges: Air Shale Gas...

440

Optimal control of a bleed air temperature regulation system.  

E-Print Network (OSTI)

??This thesis investigates temperature control of an aircraft engine bleed air system, aiming at reducing ram air usage to reduce fuel consumption while maintaining fast (more)

Shang, Lan

2007-01-01T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


441

Residential Forced Air System Cabinet Leakage and Blower Performance  

E-Print Network (OSTI)

CA. CEC(2008b). ResidentialAlternativeCalculationStandardforAirHandlersinResidentialSpaceConditioningofStandardsOptionsforResidentialAirHandlerFans.

Walker, Iain S.

2010-01-01T23:59:59.000Z

442

DOE Hydrogen and Fuel Cells Program Record 8013: Air Quality...  

NLE Websites -- All DOE Office Websites (Extended Search)

18, 2008 Title: Air Quality and Population Update to: Record 5017 Originator: Tien Nguyen Approved by: Sunita Satyapal Date: November 19, 2008 Item: "Air quality is a major...

443

A study of membrane properties on air conditioning performance.  

E-Print Network (OSTI)

??Energy consumption due to heating, ventilation, and air conditioning amounts to 10-20% of global electrical energy usage. Air conditioning alone uses one trillion kilowatt hours (more)

Boyer, Elizabeth J.

2013-01-01T23:59:59.000Z

444

The Beeping Air Conditioner : EnergySmart School Inventors  

NLE Websites -- All DOE Office Websites (Extended Search)

The Beeping Air Conditioner icon. The Beeping Air Conditioner Work in Progress Sketches Team Picture Miniature Hydroelectric Power Plant icon The Plugger icon. The Light Searcher...

445

List of Compressed air Incentives | Open Energy Information  

Open Energy Info (EERE)

Energy Efficiency Incentive Program (Texas) Local Grant Program Texas Commercial Ceiling Fan Central Air conditioners Chillers Comprehensive MeasuresWhole Building Compressed air...

446

Energy efficient indoor VOC air cleaning with activated carbon...  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy efficient indoor VOC air cleaning with activated carbon fiber (ACF) filters Title Energy efficient indoor VOC air cleaning with activated carbon fiber (ACF) filters...

447

Energy efficiency improvements in Chinese compressed air systems  

E-Print Network (OSTI)

air system assessments and energy audits based on a systemaudit. These compressed air system assessments may be conducted by compressor manufacturers/distributors or energy

McKane, Aimee; Li, Li; Li, Yuqi; Taranto, T.

2008-01-01T23:59:59.000Z

448

Air Force Achieves Fuel Efficiency through Industry Best Practices...  

NLE Websites -- All DOE Office Websites (Extended Search)

ideas and implement initiatives with the Air Force Achieves Fuel Efficiency through Industry Best Practices The Air Force Energy Plan is built upon three pillars: reduce...

449

Environmental Protection Agency Indoor Air Quality Tools for...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Environmental Protection Agency Indoor Air Quality Tools for Schools Webinar Environmental Protection Agency Indoor Air Quality Tools for Schools Webinar December 9, 2013 1:00PM...

450

Building a Common Understanding: Clean Air Act and Upcoming Carbon...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Common Understanding: Clean Air Act and Upcoming Carbon Pollution Guidelines for Existing Power Plants Webinar Building a Common Understanding: Clean Air Act and Upcoming Carbon...

451

Alternative Fuels Data Center: Air Quality Improvement Program Funding -  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Air Quality Air Quality Improvement Program Funding - Ventura County to someone by E-mail Share Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on Facebook Tweet about Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on Twitter Bookmark Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on Google Bookmark Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on Delicious Rank Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on Digg Find More places to share Alternative Fuels Data Center: Air Quality Improvement Program Funding - Ventura County on AddThis.com... More in this section...

452

Dynamic Reduction of a CH4/Air Chemical Mechanism Appropriate...  

NLE Websites -- All DOE Office Websites (Extended Search)

Dynamic Reduction of a CH4Air Chemical Mechanism Appropriate for Investigating Vortex Flame Interactions Title Dynamic Reduction of a CH4Air Chemical Mechanism Appropriate for...

453

Air Quality (Nova Scotia, Canada) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Quality (Nova Scotia, Canada) Air Quality (Nova Scotia, Canada) Eligibility Agricultural Industrial Investor-Owned Utility Multi-Family Residential MunicipalPublic Utility...

454

Air Quality Approvals and Permits (New Brunswick, Canada) | Department...  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Quality Approvals and Permits (New Brunswick, Canada) Air Quality Approvals and Permits (New Brunswick, Canada) Eligibility Commercial Construction Developer Industrial...

455

Observations on the Coke Air Reactivity Test - Programmaster.org  

Science Conference Proceedings (OSTI)

Coke air reactivities are strongly dependent on coke calcination levels and it is possible to drive air reactivities lower by increasing calcining temperatures.

456

Quantifying the Air Pollution Exposure Consequences of Distributed Electricity Generation  

E-Print Network (OSTI)

Air Resources Board, Sacramento, CA. Issued September 1999,Resources Board, Sacramento, CA. x http://www.arb.ca.gov/Air Resources Board, Sacramento, CA. Release date: Sept. 28,

Heath, Garvin A.; Granvold, Patrick W.; Hoats, Abigail S.; Nazaroff, William W

2005-01-01T23:59:59.000Z

457

Total Building Air Management: When Dehumidification Counts  

E-Print Network (OSTI)

Industry trends toward stringent indoor air quality codes, spearheaded by ASHRAE 62-89: Ventilation for Acceptable Indoor Air Quality, present four challenges to the building industry in hot and humid climates: 1. Infusion of large quantities of make-up air to code based on zone requirements 2. Maintenance of tight wet bulb and dry bulb temperature tolerances within zones based on use 3. Energy management and cost containment 4. Control of mold and mildew and the damage they cause Historically, total air management of sensible and latent heat, filtration and zone pressure was brought about through the implementation of non-integrated, composite systems. Composite systems typically are built up of multi-vendor equipment each of which perform specific, independent functions in the total control of the indoor air environment. Composite systems have a high up-front cost, are difficult to maintain and are costly to operate. Today, emerging technologies allow the implementation of fully integrated system for total building air management. These systems provide a single-vendor solution that is cost effective to purchase, maintain and operate. Operating saving of 23% and ROIs of 2.3 years have been shown. Equipment specification is no longer based primarily on total building load. Maximum benefits of these dynamic systems are realized when systems are designed with a total operating strategy in mind. This strategy takes into consideration every factor of building air management including: 1. Control of sensible heat 2. Balance management of heat rejection 3. Latent heat management 4. Control of process hot water 5. Indoor air quality management 6. Containment of energy consumption 7. Load shedding

Chilton, R. L.; White, C. L.

1996-01-01T23:59:59.000Z

458

Dehumidification and cooling loads from ventilation air  

SciTech Connect

The importance of controlling humidity in buildings is cause for concern, in part, because of indoor air quality problems associated with excess moisture in air-conditioning systems. But more universally, the need for ventilation air has forced HVAC equipment (originally optimized for high efficiency in removing sensible heat loads) to remove high moisture loads. To assist cooling equipment and meet the challenge of larger ventilation loads, several technologies have succeeded in commercial buildings. Newer technologies such as subcool/reheat and heat pipe reheat show promise. These increase latent capacity of cooling-based systems by reducing their sensible capacity. Also, desiccant wheels have traditionally provided deeper-drying capacity by using thermal energy in place of electrical power to remove the latent load. Regardless of what mix of technologies is best for a particular application, there is a need for a more effective way of thinking about the cooling loads created by ventilation air. It is clear from the literature that all-too-frequently, HVAC systems do not perform well unless the ventilation air loads have been effectively addressed at the original design stage. This article proposes an engineering shorthand, an annual load index for ventilation air. This index will aid in the complex process of improving the ability of HVAC systems to deal efficiently with the amount of fresh air the industry has deemed useful for maintaining comfort in buildings. Examination of typical behavior of weather shows that latent loads usually exceed sensible loads in ventilation air by at least 3:1 and often as much as 8:1. A designer can use the engineering shorthand indexes presented to quickly assess the importance of this fact for a given system design. To size those components after they are selected, the designer can refer to Chapter 24 of the 1997 ASHRAE Handbook--Fundamentals, which includes separate values for peak moisture and peak temperature.

Harriman, L.G. III [Mason-Grant, Portsmouth, NH (United States); Plager, D. [Quantitative Decision Support, Portsmouth, NH (United States); Kosar, D. [Gas Research Inst., Chicago, IL (United States)

1997-11-01T23:59:59.000Z

459

Multimedia Impacts of Air Pollutant Controls  

Science Conference Proceedings (OSTI)

With federal and state restrictions on air pollutant emissions growing more stringent, cross-media transfer may increase their concentration in solid waste and wastewater in complex chemical settings that make it difficult to predict pollutant behavior, both within the power plant and in the outside environment. Recent EPRI research addresses these complexities and helps to clarify impacts to solid waste and wastewater resulting from air pollution control operation. The ultimate goal of this ...

2013-05-28T23:59:59.000Z

460

Compressed Air Storage for Electric Power Generation  

Science Conference Proceedings (OSTI)

This Technical Report focuses on the use of underground storage of natural gas as a means of leveling the load between supply and demand. The book presents a view of the way compressed air storage can reduce costs when constructing new facilities for generating peak load electricity. The primary emphasis given concerns underground storage of air in underground porous media, the vehicle utilized on a large scale for over 25 years by the natural gas industry.

1990-06-01T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


461

Hanford Site air operating permit application  

SciTech Connect

The Clean Air Act Amendments of 1990, which amended the Federal Clean Air Act of 1977, required that the US Environmental Protection Agency develop a national Air Operating Permit Program, which in turn would require each state to develop an Air Operating Permit Program to identify all sources of ``regulated`` pollutants. Regulated pollutants include ``criteria`` pollutants (oxides of nitrogen, sulfur oxides, total suspended particulates, carbon monoxide, particulate matter greater than 10 micron, lead) plus 189 other ``Hazardous`` Air Pollutants. The Hanford Site, owned by the US Government and operated by the US Department of Energy, Richland Operations Office, is located in southcentral Washington State and covers 560 square miles of semi-arid shrub and grasslands located just north of the confluence of the Snake and Yakima Rivers with the Columbia River. This land, with restricted public access, provides a buffer for the smaller areas historically used for the production of nuclear materials, waste storage, and waste disposal. About 6 percent of the land area has been disturbed and is actively used. The Hanford Site Air Operating Permit Application consists of more than 1,100 sources and in excess of 300 emission points. Before January 1995, the maintenance and operations contractor and the environmental restoration contractor for the US Department of Energy completed an air emission inventory on the Hanford Site. The inventory has been entered into a database so that the sources and emission points can be tracked and updated information readily can be retrieved. The Hanford Site Air Operating Permit Application contains information current as of April 19, 1995.

NONE

1995-05-01T23:59:59.000Z

462

Air Emission Regulations for the Prevention, Abatement, and Control of Air  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air Emission Regulations for the Prevention, Abatement, and Control Air Emission Regulations for the Prevention, Abatement, and Control of Air Contaminants (Mississippi) Air Emission Regulations for the Prevention, Abatement, and Control of Air Contaminants (Mississippi) < Back Eligibility Agricultural Commercial Construction Developer Fed. Government Fuel Distributor General Public/Consumer Industrial Installer/Contractor Institutional Investor-Owned Utility Local Government Low-Income Residential Multi-Family Residential Municipal/Public Utility Nonprofit Residential Retail Supplier Rural Electric Cooperative Schools State/Provincial Govt Systems Integrator Transportation Tribal Government Utility Program Info State Mississippi Program Type Environmental Regulations Siting and Permitting Provider Department of Environmental Quality The Air Emission Regulation for the Prevention, Abatement and Control of

463

Linear air-fuel sensor development  

DOE Green Energy (OSTI)

The electrochemical zirconia solid electrolyte oxygen sensor, is extensively used for monitoring oxygen concentrations in various fields. They are currently utilized in automobiles to monitor the exhaust gas composition and control the air-to-fuel ratio, thus reducing harmful emission components and improving fuel economy. Zirconia oxygen sensors, are divided into two classes of devices: (1) potentiometric or logarithmic air/fuel sensors; and (2) amperometric or linear air/fuel sensors. The potentiometric sensors are ideally suited to monitor the air-to-fuel ratio close to the complete combustion stoichiometry; a value of about 14.8 to 1 parts by volume. This occurs because the oxygen concentration changes by many orders of magnitude as the air/fuel ratio is varied through the stoichiometric value. However, the potentiometric sensor is not very sensitive to changes in oxygen partial pressure away from the stoichiometric point due to the logarithmic dependence of the output voltage signal on the oxygen partial pressure. It is often advantageous to operate gasoline power piston engines with excess combustion air; this improves fuel economy and reduces hydrocarbon emissions. To maintain stable combustion away from stoichiometry, and enable engines to operate in the excess oxygen (lean burn) region several limiting-current amperometric sensors have been reported. These sensors are based on the electrochemical oxygen ion pumping of a zirconia electrolyte. They typically show reproducible limiting current plateaus with an applied voltage caused by the gas diffusion overpotential at the cathode.

Garzon, F. [Los Alamos National Lab., NM (United States); Miller, C. [General Motors, Flint, MI (United States). GM/Delphi E. Division

1996-12-14T23:59:59.000Z

464

Air transport of plutonium metal : content expansion initiative for the Plutonium Air Transportable (PAT-1) packaging.  

SciTech Connect

The National Nuclear Security Administration (NNSA) has submitted an application to the Nuclear Regulatory Commission (NRC) for the air shipment of plutonium metal within the Plutonium Air Transportable (PAT-1) packaging. The PAT-1 packaging is currently authorized for the air transport of plutonium oxide in solid form only. The INMM presentation will provide a limited overview of the scope of the plutonium metal initiative and provide a status of the NNSA application to the NRC.

Mann, Paul T. (National Nuclear Security Administration); Caviness, Michael L. (Los Alamos National Laboratory); Yoshimura, Richard Hiroyuki

2010-06-01T23:59:59.000Z

465

Air transport of plutonium metal: content expansion initiative for the plutonium air transportable (PAT01) packaging  

Science Conference Proceedings (OSTI)

The National Nuclear Security Administration (NNSA) has submitted an application to the Nuclear Regulatory Commission (NRC) for the air shipment of plutonium metal within the Plutonium Air Transportable (PAT-1) packaging. The PAT-1 packaging is currently authorized for the air transport of plutonium oxide in solid form only. The INMM presentation will provide a limited overview of the scope of the plutonium metal initiative and provide a status of the NNSA application to the NRC.

Caviness, Michael L [Los Alamos National Laboratory; Mann, Paul T [NNSA/ALBUQUERQUE; Yoshimura, Richard H [SNL

2010-01-01T23:59:59.000Z

466

Performance of an air-cooled ammonia-water absorption air conditioner at low generator temperatures  

DOE Green Energy (OSTI)

An ammonia--water absorption air conditioning system has been tested to investigate the stability of operation near the cut-off conditions. Circulation ratios were from 8 to 30. Relations for the estimation of the coefficient of performance and for the prediction of operating temperatures were derived and verified experimentally. Possible operating conditions for an air-cooled ammonia--water air conditioning system were concluded.

Dao, K.; Simmons, M.; Wolgast, R.; Wahlig, M.

1976-08-01T23:59:59.000Z

467

Abatement of Air Pollution: Air Pollution Control Equipment and Monitoring Equipment Operation (Connecticut)  

Energy.gov (U.S. Department of Energy (DOE))

These regulations contain instructions for the operation and monitoring of air pollution control equipment, as well as comments on procedures in the event of equipment breakdown, failure, and...

468

Seminar 14 - Desiccant Enhanced Air Conditioning: Desiccant Enhanced Evaporative Air Conditioning (Presentation)  

SciTech Connect

This presentation explains how liquid desiccant based coupled with an indirect evaporative cooler can efficiently produce cool, dry air, and how a liquid desiccant membrane air conditioner can efficiently provide cooling and dehumidification without the carryover problems of previous generations of liquid desiccant systems. It provides an overview to a liquid desiccant DX air conditioner that can efficiently provide cooling and dehumidification to high latent loads without the need for reheat, explains how liquid desiccant cooling and dehumidification systems can outperform vapor compression based air conditioning systems in hot and humid climates, explains how liquid desiccant cooling and dehumidification systems work, and describes a refrigerant free liquid desiccant based cooling system.

Kozubal, E.

2013-02-01T23:59:59.000Z

469

Neural network control for an intelligent air handler in an air-conditioning system.  

E-Print Network (OSTI)

??Many commercial air-conditioning systems in hot and humid areas like Singapore are operated throughout the year. There are two main classifications for these systems: the (more)

Zhang, Qi.

2008-01-01T23:59:59.000Z

470

Reducing Air Compressor Work by Using Inlet Air Cooling and Dehumidification.  

E-Print Network (OSTI)

??Air compressor systems play a large role in modern industry. These compressors can account for a significant portion of a manufacturing facilitys electric consumption and (more)

Hardy, Mark James

2011-01-01T23:59:59.000Z

471

Characteristics of ashes from different locations at the MSW incinerator equipped with various air pollution control devices  

Science Conference Proceedings (OSTI)

The characteristics of ashes from different locations at a municipal solid waste incinerator (MSWI) equipped with a water spray tower (WST) as a cooling system, and a spray dryer adsorber (SDA), a bag filter (BF) and a selective catalytic reactor (SCR) as air pollution control devices (APCD) was investigated to provide the basic data for further treatment of ashes. A commercial MSWI with a capacity of 100 tons per day was selected. Ash was sampled from different locations during the normal operation of the MSWI and was analyzed to obtain chemical composition, basicity, metal contents and leaching behavior of heavy metals. Basicity and pH of ash showed a broad range between 0.08-9.07 and 3.5-12.3, respectively. Some major inorganics in ash were identified and could affect the basicity. This could be one of the factors to determine further treatment means. Partitioning of hazardous heavy metals such as Pb, Cu, Cr, Hg and Cd was investigated. Large portions of Hg and Cd were emitted from the furnace while over 90% of Pb, Cu and Cr remained in bottom ash. However 54% of Hg was captured by WST and 41% by SDA/BF and 3.6% was emitted through the stack, while 81.5% of Cd was captured by SDA/BF. From the analysis data of various metal contents in ash and leach analysis, such capturing of metal was confirmed and some heavy metals found to be easily released from ash. Based on the overall characteristics of ash in different locations at the MSWI during the investigation, some considerations and suggestions for determining the appropriate treatment methods of ash were made as conclusions.

Song, Geum-Ju; Kim, Ki-Heon; Seo, Yong-Chil; Kim, Sam-Cwan

2004-07-01T23:59:59.000Z

472

Study of Air Infiltration Energy Consumption  

E-Print Network (OSTI)

The influence of heat recovery on the energy impact of air infiltration, and the systematic error due to the steady-state method were studied both experimentally and theoretically. Two methodologies suitable for measurement of the overall heat loss factors in full-size houses have been developed and validated. Dynamic measurements of Infiltration Heat Exchange effectiveness (IHEE), which expresses the air infiltration heat recovery as a fraction of the classical value of air infiltration energy consumption, showed that results from earlier steady-state measurements can be approximately applied to dynamic conditions when solar radiation is not present. However, this study has shown for the first time that IHEE is strongly dependent on air flow direction due to the impacts of air flow on the recovery or rejection of solar radiation energy. IHEE values greater than one and less than zero have been measured. These values are impossible in the absence of solar radiation. The results highlight the necessity of considering the air infiltration heat recovery and improving the current design methods for calculating the heating and cooling loads in buildings. The experimental and theoretical investigation show that steady-state methodology can: *be used without systematic error in the case of constant air flow *result in IHEE prediction error in a range of 1% to 8% when one-way dynamic air f1ow is present *cause significantly larger error when balanced dynamic air flow is present. The SSP (Single input and Single output data Pair) method can identify UAo of an enclosure using short term measurement data, typically a few hours long. It has overcome most of the typical problems in UA0 identification, such as errors due to thermal storage, ground heat transfer, inter-correlated multi-inputs, and solar radiation. The STAM (Short Term Average Method) has also been developed which makes it possible for the first time to determine both the UA and the solar aperture precisely under outdoor conditions from a two-day or a three-day test. These methods were developed and used to measure heat loss factors needed to determine IHEE values in this study.

Liu, Mingsheng

1992-08-01T23:59:59.000Z

473

Simulation of air flow in the typical boiler windbox segments  

Science Conference Proceedings (OSTI)

Simulation of turbulent air flow distribution in CFBC furnace, wherein primary air is entrained through inlet duct system called windbox, is attempted through state of art CAD/CFD softwares. Establishment of flow in windbox channel, distributed plate ... Keywords: CFBC boiler, air flow, combustor geometry, distributed plate nozzles, multi-block grids, recirculation flow, simulation of flow, unequal air flow, windbox channel

C. Bhasker

2002-12-01T23:59:59.000Z

474

Issue and Improvement Measure of Multi-split Air Conditioner  

Science Conference Proceedings (OSTI)

Existing problems of traditional air source variable refrigerant flow (VRF) air-conditioning system are analyzed. The disadvantages of traditional VRF air-conditioning system are described in detail: 1) its properties are seriously affected by outdoor ... Keywords: energy saving, simulation, variable refrigerant flow air conditioning, water loop

Sun Tingting; Ni Long; Yao Yang; Ma Zuiliang; Yi Lingli

2011-02-01T23:59:59.000Z

475

Modeling the Air Traffic Controller's Cognitive Projection Process  

E-Print Network (OSTI)

Cognitive projection enables the operator of a supervisory control system, such as air traffic control, to

Davison Reynolds, Hayley J

2006-11-20T23:59:59.000Z

476

Review and Assessment of Air Quality Management Activities in Texas  

Science Conference Proceedings (OSTI)

Many air quality studies indicate that ozone, fine particulates, and haze are interrelated and often regional in extent. Emission management strategies to mitigate these pollutants are likely to involve regional control measures. This report summarizes recent air quality studies in the State of Texas to support the development of integrated air quality management strategies to meet new air quality standards.

1999-07-02T23:59:59.000Z

477

Bagging and Boosting statistical machine translation systems  

Science Conference Proceedings (OSTI)

In this article we address the issue of generating diversified translation systems from a single Statistical Machine Translation (SMT) engine for system combination. Unlike traditional approaches, we do not resort to multiple structurally different SMT ... Keywords: Ensemble learning, Statistical machine translation, System combination

Tong Xiao; Jingbo Zhu; Tongran Liu

2013-02-01T23:59:59.000Z

478

Radioactive air emissions 1992 summary. Progress report  

Science Conference Proceedings (OSTI)

This report summarizes, by radionuclide or product and by emitting facility, the Laboratory`s 1992 radioactive air emissions. In 1992, the total activity of radionuclides emitted into the air from Laboratory stacks was approximately 73,500 Ci. This was an increase over the activity of the total 1991 radioactive air emissions, which was approximately 62,400 Ci. Total 1992 Laboratory emissions of each radionuclide or product are summarized by tables and graphs in the first section of this report. Compared to 1991 radioactive air emissions, total tritium activity was decreased, total plutonium activity was decreased, total uranium activity was decreased, total mixed fission product activity was increased, total {sup 41}Ar activity was decreased, total gaseous/mixed activation product (except {sup 41}Ar) activity was increased, total particulate/vapor activation product activity was increased, and total {sup 32}P activity was decreased. Radioactive emissions from specific facilities are detailed in this report. Each section provides 1992 data on a single radionuclide or product and is further divided by emitting facility. For each facility from which a particular radionuclide or product was emitted, a bar chart displays the air emissions of each radionuclide or product from each facility over the 12 reporting periods of 1992, a line chart shows the trend in total emissions of that radionuclide or product from that facility for the past three years, the greatest activity during the 1990--1992 period is discussed, and unexpected or unusual results are noted.

Wahl, L. [comp.

1993-10-01T23:59:59.000Z

479

Comprehensive air monitoring plan: general monitoring report  

DOE Green Energy (OSTI)

Recommendations are provided for general monitoring of hydrogen sulfide (H/sub 2/S) in ambient air in parts of Colusa, Lake, Mendocino, Napa, and Sonoma counties potentially impacted by emissions from geothermal development projects in the Geysers-Calistoga Known Geothermal Resource Area. Recommendations for types, placement, performance guidelines, and criteria and procedure for triggering establishment and termination of CAMP monitoring equipment were determined after examination of four factors: population location; emission sources; meteorological considerations; and data needs of permitting agencies and applicants. Three alternate financial plans were developed. Locations and equipment for immediate installation are recommended for: two air quality stations in communities where the State ambient air quality standard for H/sub 2/S has been exceeded; three air quality trend stations to monitor progress in reduction of H/sub 2/S emissions; two meteorological observation stations to monitor synoptic wind flow over the area; and one acoustic radar and one rawinsonde station to monitor air inversions which limit the depth of the mixing layer.

Not Available

1980-03-31T23:59:59.000Z

480

Design specifications for the air mobility operations simulation environment (Air MOOSE)  

Science Conference Proceedings (OSTI)

The Canadian Forces (CF) air mobility community is facing a period of considerable transition over the next decade or so as its fixed wing airlift capability, represented primarily by the aging C-130 fleet of E- and H-model Hercules and a fleet of five ... Keywords: Canadian Forces, air mobility, airlift operations, discrete event simulation

David W. Mason

2009-03-01T23:59:59.000Z

Note: This page contains sample records for the topic "braking air bags" from the National Library of EnergyBeta (NLEBeta).
While these samples are representative of the content of NLEBeta,
they are not comprehensive nor are they the most current set.
We encourage you to perform a real-time search of NLEBeta
to obtain the most current and comprehensive results.


481

A Theoretical Study of Cold Air Damming with Upstream Cold Air Inflow  

Science Conference Proceedings (OSTI)

The previously developed two-layer model of cold air damming is extended to include upstream cold air inflow. The upper layer is an isentropic cross-mountain flow. The lower layer is a cold boundary layer flow partially blocked by a two-...

Qin Xu; Shouting Gao; Brian H. Fiedler

1996-01-01T23:59:59.000Z

482

An Air-Driven Pressure Booster Pump for Aircraft-Based Air Sampling  

Science Conference Proceedings (OSTI)

A diaphragm pump used to boost the intake pressure of a three-stage high-pressure air compressor for collecting large air samples during aircraft flights has been developed. The pump consists of a large (17 L) spherical body divided into two ...

C. A. M. Brenninkmeijep; P. A. Roberts

1994-12-01T23:59:59.000Z

483

VEHICLE SPECIFICATIONS Vehicle Features Base Vehicle: 2010 Volkswagen  

NLE Websites -- All DOE Office Websites (Extended Search)

Golf TDI Bluemotion VIN: WVWZZZ1KZAW388111 Seatbelt Positions: 5 Standard Features: Air Conditioning Power Locks Power Steering Power Brakes Power Windows Cruise Control...

484

PERFORMANCE STATISTICS WEIGHTS  

NLE Websites -- All DOE Office Websites (Extended Search)

2006 Honda Civic VIN: JHMFA36216S019329 Seatbelt Positions: Five Standard Features: Air Conditioning Power Locks Power Steering Power Brakes Power Windows Cruise Control Space...

485

Chapter 53 Ambient Air Quality (Kentucky) | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

3 Ambient Air Quality (Kentucky) 3 Ambient Air Quality (Kentucky) Chapter 53 Ambient Air Quality (Kentucky) < Back Eligibility Agricultural Commercial Construction Developer Industrial Installer/Contractor Investor-Owned Utility Municipal/Public Utility Rural Electric Cooperative Utility Program Info State Kentucky Program Type Environmental Regulations Safety and Operational Guidelines Provider Kentucky Department for Environmental Protection Kentucky Administrative Regulation Chapter 53, entitled Ambient Air Quality, is promulgated under the authority of the Division of Air Quality within the Energy and Environment Cabinet's Department for Environmental Protection. Chapter 53 sets the air quality standards for pollutants regulated under the federally mandated Clean Air Act. The purpose of the

486

Air-Quality Improvement Tax Incentives | Department of Energy  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Air-Quality Improvement Tax Incentives Air-Quality Improvement Tax Incentives Air-Quality Improvement Tax Incentives < Back Eligibility Commercial Industrial Savings Category Heating & Cooling Commercial Heating & Cooling Heating Cooling Other Appliances & Electronics Commercial Lighting Lighting Manufacturing Bioenergy Buying & Making Electricity Solar Water Heating Wind Program Info State Ohio Program Type Other Incentive Provider Ohio Air Quality Development Authority The Ohio Air Quality Development Authority (OAQDA) provides assistance for new air quality projects in Ohio, for both small and large businesses. For qualifying projects, the OAQDA also projects tax benefits. For qualifying projects, the Ohio Air Quality Development Authority (OAQDA) can provide a 100 percent exemption from the tangible personal property tax

487

Building Technologies Office: Energy-Efficient Window Air Conditioner  

NLE Websites -- All DOE Office Websites (Extended Search)

Energy-Efficient Window Energy-Efficient Window Air Conditioner Ratings Research Project to someone by E-mail Share Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Facebook Tweet about Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Twitter Bookmark Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Google Bookmark Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Delicious Rank Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on Digg Find More places to share Building Technologies Office: Energy-Efficient Window Air Conditioner Ratings Research Project on

488

Buenos Aires, Argentina: Energy Resources | Open Energy Information  

Open Energy Info (EERE)

Buenos Aires, Argentina: Energy Resources Buenos Aires, Argentina: Energy Resources Jump to: navigation, search Equivalent URI DBpedia GeoNames ID 3435910 This article is a stub. You can help OpenEI by expanding it. Buenos Aires is the capital of Argentina. Contents 1 Registered Networking Organizations in Buenos Aires, Argentina 2 Registered Policy Organizations in Buenos Aires, Argentina 3 Registered Energy Companies in Buenos Aires, Argentina 4 References Registered Networking Organizations in Buenos Aires, Argentina Asociacion Argentina de Energia Eolica Registered Policy Organizations in Buenos Aires, Argentina Proyecto de Energias Renovables en Mercados Rurales Registered Energy Companies in Buenos Aires, Argentina Dalkia Argentina References Retrieved from "http://en.openei.org/w/index.php?title=Buenos_Aires,_Argentina&oldid=270464"

489

Alternative Fuels Data Center: Air Pollution Control Program  

Alternative Fuels and Advanced Vehicles Data Center (EERE)

Air Pollution Control Air Pollution Control Program to someone by E-mail Share Alternative Fuels Data Center: Air Pollution Control Program on Facebook Tweet about Alternative Fuels Data Center: Air Pollution Control Program on Twitter Bookmark Alternative Fuels Data Center: Air Pollution Control Program on Google Bookmark Alternative Fuels Data Center: Air Pollution Control Program on Delicious Rank Alternative Fuels Data Center: Air Pollution Control Program on Digg Find More places to share Alternative Fuels Data Center: Air Pollution Control Program on AddThis.com... More in this section... Federal State Advanced Search All Laws & Incentives Sorted by Type Air Pollution Control Program The Air Pollution Control Program assists state, local, and tribal agencies in planning, developing, establishing, improving, and maintaining adequate

490

The Effect of Reduced Evaporator Air Flow on the Performance of a Residential Central Air Conditioner  

E-Print Network (OSTI)

This paper discusses the measured degradation in performance of a residential air conditioning system operating under reduced evaporator air flow. Experiments were conducted using a R-22 three-ton split-type cooling system with a short-tube orifice expansion device. Results are presented here for a series of tests in which the evaporator air flow was reduced from 25 to 90% below what is normally recommended for this air conditioner. At present, very little information is available which quantifies the performance of a residential cooling system operating under degraded conditions such as reduced evaporator air flow. Degraded performance measurements can provide information which could help electric utilities evaluate the potential impact of system-wide maintenance programs.

Palani, M.; O'Neal, D.; Haberl, J.

1992-05-01T23:59:59.000Z

491

Stakeholder perspectives on the Clean Air Interstate and the Clean Air Mercury Rules  

Science Conference Proceedings (OSTI)

In a follow-up to last month's detailed overviews of the Clean Air Interstate Rule (CAIR) and the Clean Air Mercury Rule (CAMR), this month EM presents perspectives on the two rules from representatives of a range of stakeholders, including EPA, the states, the regulated community, and the environmental community. Titles of the perspectives are: A Multipollutant Approach to Emissions Reductions; Clean Air Lessons from the Myth of Sisyphus; Reactions to EPA's Clean Air Interstate and Clean Air Mercury Rules; The Case for Coal Rank Subcategorization to Regulate Mercury Emissions; EPA's Mercury Rule: The Latest Delay Tactic; EPA's Mercury Rule: With Technology Today, We Can Do Better; STAPPA/ALAPCO's Perspectives on CAMR and CAIR. 16 refs.

C.V. Mathai; Jeffrey Holmstead; Michael Shore; Skiles Boyd; Vicky Sullivan; Dan Weiss; John Kinsman; Steve Lomax; Michael Rossler; David Steele; Greg Schaefer; Felice Stadler; David Foerter; William Becker [Arizona Public Services, Phoenix, AZ (US)

2005-08-01T23:59:59.000Z

492

A Survey: Indoor Air Quality in Schools  

NLE Websites -- All DOE Office Websites (Extended Search)

3 3 A Survey: Indoor Air Quality in Schools We recently undertook a survey and critical review of the published literature on indoor air quality (IAQ), ventilation, and IAQ- and building-related health problems in schools, particularly those in the state of California. The survey's objectives included identifying the most commonly reported building-related health symptoms involving schools, and assembling and evaluating existing measurement data on key indoor air pollutants most likely to be related to these symptoms. The review also summarizes existing measurements of ventilation rates in schools and information on the causes of IAQ and health problems in schools. Most of the literature we reviewed (more than 450 articles and reports) dealt with complaint or problem schools. Among the papers were

493

Air Liquide - Biogas & Fuel Cells  

NLE Websites -- All DOE Office Websites (Extended Search)

Liquide - Biogas & Fuel Cells Liquide - Biogas & Fuel Cells ■ Hydrogen Energy ■ Biogas Upgrading Technology 12 June 2012 Charlie.Anderson@airliquide.com 2 Air Liquide, world leader in gases for industry, health and the environment Renewable H 2 to Fuel Cell, Integrated Concept Purified Biogas 3 Air Liquide, world leader in gases for industry, health and the environment Renewable H 2 to Fuel Cell, Non-Integrated Concept Landfill WWTP digester Biogas membrane Pipeline quality methane CH4 Pipeline Hydrogen Production To Fuel Cell Vehicles Stationary Fuel Cells With H2 purification Stationary Fuel Cells Direct Conversion Directed Biomethane 4 Air Liquide, world leader in gases for industry, health and the environment Biogas Sources in the US ■ Landfill gas dominates (~4,000 Nm3/h typical)

494

Improving Air Conditioner and Heat Pump Modeling  

Energy.gov (U.S. Department of Energy (DOE)) Indexed Site

Improving Air-Conditioner Improving Air-Conditioner and Heat Pump Modeling Building America Stakeholders Meeting Jon Winkler March 2, 2012 2 * How do you recommend the most cost-effective A/C? Simple Question 3 Solution Whole-House Simulation Tool A/C Information * SEER 13 * SEER 14 * SEER 15 * SEER 16 * SEER 17 * SEER 18 * SEER 21 Annualized Cooling Cost (Energy + Equipment) 4 Background * Power, capacity and SHR vary with: o Outdoor temperature o Entering wetbulb o Air mass flow rate o Part load ratio Power Sensible Capacity Latent Capacity * How to accurately and easily model A/C performance? 5 Background: Model Development * A/C modeling utilizes two types of input o Rated values (capacity, efficiency, etc.) o Performance curves Capacity 1 / Efficiency 6 Background: Manufacturer's Data

495

ARM - Campaign Instrument - rad-air  

NLE Websites -- All DOE Office Websites (Extended Search)

govInstrumentsrad-air govInstrumentsrad-air Comments? We would love to hear from you! Send us a note below or call us at 1-888-ARM-DATA. Send Campaign Instrument : Airborne Radiometers (RAD-AIR) Instrument Categories Radiometric, Airborne Observations Campaigns Indirect and Semi-Direct Aerosol Campaign (ISDAC) [ Download Data ] North Slope Alaska, 2008.04.01 - 2008.04.30 Routine AAF CLOWD Optical Radiative Observations (RACORO) [ Download Data ] Southern Great Plains, 2009.01.22 - 2009.06.30 Routine AAF CLOWD Optical Radiative Observations (RACORO) [ Download Data ] Southern Great Plains, 2009.01.22 - 2009.06.30 Routine AAF CLOWD Optical Radiative Observations (RACORO) [ Download Data ] Southern Great Plains, 2009.01.22 - 2009.06.30 Primary Measurements Taken The following measurements are those considered scientifically relevant.

496

Rotating heat pipe for air-conditioning  

SciTech Connect

A unique rotary hermetic heat pipe is disclosed for transferring heat from an external source to an external heat sink. The heat pipe has a tapered condensing surface which is curved preferably to provide uniform pumping acceleration, the heat pipe being rotated at a velocity such that the component of centrifugal acceleration in an axial direction parallel to the tapered surface is greater than lG and so that the condensing surface is kept relatively free of liquid at any attitude. The heat pipe may be incorporated in an air conditioning apparatus so that it projects through a small wall opening. In the preferred air conditioning apparatus, a hollow hermetic air impeller is provided which contains a liquefied gaseous refrigerant, such as freon, and means are provided for compressing the refrigerant in the evaporator region of the heat pipe.

Gray, V.H.

1976-12-28T23:59:59.000Z

497

High strength air-dried aerogels  

Science Conference Proceedings (OSTI)

A method for the preparation of high strength air-dried organic aerogels. The method involves the sol-gel polymerization of organic gel precursors, such as resorcinol with formaldehyde (RF) in aqueous solvents with R/C ratios greater than about 1000 and R/F ratios less than about 1:2.1. Using a procedure analogous to the preparation of resorcinol-formaldehyde (RF) aerogels, this approach generates wet gels that can be air dried at ambient temperatures and pressures. The method significantly reduces the time and/or energy required to produce a dried aerogel compared to conventional methods using either supercritical solvent extraction. The air dried gel exhibits typically less than 5% shrinkage.

Coronado, Paul R.; Satcher, Jr., Joe H.

2012-11-06T23:59:59.000Z

498

Equivalence in Ventilation and Indoor Air Quality  

SciTech Connect

We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

Sherman, Max; Walker, Iain; Logue, Jennifer

2011-08-01T23:59:59.000Z

499

Solar Powered Radioactive Air Monitoring Stations  

SciTech Connect

Environmental monitoring of ambient air for radioactive material is required as stipulated in the PNNL Site radioactive air license. Sampling ambient air at identified preferred locations could not be initially accomplished because utilities were not readily available. Therefore, solar powered environmental monitoring systems were considered as a possible option. PNNL purchased two 24-V DC solar powered environmental monitoring systems which consisted of solar panels, battery banks, and sampling units. During an approximate four month performance evaluation period, the solar stations operated satisfactorily at an on-site test location. They were subsequently relocated to their preferred locations in June 2012 where they continue to function adequately under the conditions found in Richland, Washington.

Barnett, J. M.; Bisping, Lynn E.; Gervais, Todd L.

2013-10-30T23:59:59.000Z

500

Life-cycle cost and payback period analysis for commercial unitary air conditioners  

E-Print Network (OSTI)

ground water source), electrically operated, unitary central air conditioners and central air conditioning heat pumps

Rosenquist, Greg; Coughlin, Katie; Dale, Larry; McMahon, James; Meyers, Steve

2004-01-01T23:59:59.000Z